WorldWideScience

Sample records for localized mn implantation

  1. Ferromagnetism in Mn-Implanted Epitaxially Grown Ge on Si(100)

    Energy Technology Data Exchange (ETDEWEB)

    Guchhait, S.; Jamil, M.; Ohldag, H.; Mehta, A.; Arenholz, E.; Lian, G.; Li Fatou, A.; Ferrer, D. A.; Markert, J. T.; Colombo, L.; Banerjee, S. K.

    2011-01-05

    We have studied ferromagnetism of Mn-implanted epitaxial Ge films on silicon. The Ge films were grown by ultrahigh vacuum chemical vapor deposition using a mixture of germane (GeH{sub 4}) and methylgermane (CH{sub 3}GeH{sub 3}) gases with a carbon concentration of less than 1 at. %, and observed surface rms roughness of 0.5 nm, as measured by atomic force microscopy. Manganese ions were implanted in epitaxial Ge films grown on Si (100) wafers to an effective concentration of 16, 12, 6, and 2 at. %. Superconducting quantum interference device measurements showed that only the three highest Mn concentration samples are ferromagnetic, while the fourth sample, with [Mn] = 2 at. %, is paramagnetic. X-ray absorption spectroscopy and x-ray magnetic circular dichroism measurements indicate that localized Mn moments are ferromagnetically coupled below the Curie temperature. Isothermal annealing of Mn-implanted Ge films with [Mn] = 16 at. % at 300 C for up to 1200 s decreases the magnetization but does not change the Curie temperature, suggesting that the amount of the magnetic phase slowly decreases with time at this anneal temperature. Furthermore, transmission electron microscopy and synchrotron grazing incidence x-ray diffraction experiments show that the Mn-implanted region is amorphous, and we believe that it is this phase that is responsible for the ferromagnetism. This is supported by our observation that high-temperature annealing leads to recrystallization and transformation of the material into a paramagnetic phase.

  2. Ferromagnetism in Mn-Implanted Epitaxially Grown Ge on Si(100)

    Energy Technology Data Exchange (ETDEWEB)

    Guchhait, S.; Jamil, M.; Ohldag, H.; Mehta, A.; Arenholz, E.; Lian, G.; Li Fatou, A.; Ferrer, D. A.; Markert, J. T.; Colombo, L.; Banerjee, S. K.

    2011-01-05

    We have studied ferromagnetism of Mn-implanted epitaxial Ge films on silicon. The Ge films were grown by ultrahigh vacuum chemical vapor deposition using a mixture of germane (GeH{sub 4}) and methylgermane (CH{sub 3}GeH{sub 3}) gases with a carbon concentration of less than 1 at. %, and observed surface rms roughness of 0.5 nm, as measured by atomic force microscopy. Manganese ions were implanted in epitaxial Ge films grown on Si (100) wafers to an effective concentration of 16, 12, 6, and 2 at. %. Superconducting quantum interference device measurements showed that only the three highest Mn concentration samples are ferromagnetic, while the fourth sample, with [Mn] = 2 at. %, is paramagnetic. X-ray absorption spectroscopy and x-ray magnetic circular dichroism measurements indicate that localized Mn moments are ferromagnetically coupled below the Curie temperature. Isothermal annealing of Mn-implanted Ge films with [Mn] = 16 at. % at 300 C for up to 1200 s decreases the magnetization but does not change the Curie temperature, suggesting that the amount of the magnetic phase slowly decreases with time at this anneal temperature. Furthermore, transmission electron microscopy and synchrotron grazing incidence x-ray diffraction experiments show that the Mn-implanted region is amorphous, and we believe that it is this phase that is responsible for the ferromagnetism. This is supported by our observation that high-temperature annealing leads to recrystallization and transformation of the material into a paramagnetic phase.

  3. On the state of Mn impurity implanted in Si

    Energy Technology Data Exchange (ETDEWEB)

    Orlov, A. F., E-mail: rmdp@girmet.ru [State Institute for Rare Metals (Russian Federation); Bublik, V. T. [Moscow State Institute of Steel and Alloys (Russian Federation); Vdovin, V. I. [Institute for Chemical Problems of Microelectronics (Russian Federation); Agafonov, Yu. A. [Russian Academy of Sciences, Institute of Microelectronics, Technology, and High Purity Materials (Russian Federation); Balagurov, L. A. [State Institute for Rare Metals (Russian Federation); Zinenko, V. I. [Russian Academy of Sciences, Institute of Microelectronics, Technology, and High Purity Materials (Russian Federation); Kulemanov, I. V. [State Institute for Rare Metals (Russian Federation); Shcherbachev, K. D. [Moscow State Institute of Steel and Alloys (Russian Federation)

    2009-07-15

    The state of manganese impurity in implanted silicon at implantation doses of up to 5 x 10{sup 16} cm{sup -2} has been investigated by X-ray diffraction and transmission electron microscopy. It is established that, after short-term vacuum annealing at 850{sup o}C, most of the implanted manganese impurities are in microinclusions up to 20 nm in size formed by a tetragonal silicide phase of the Mn{sub 15}Si{sub 26} type.

  4. Cathodoluminescence and Magnetic Properties of Mn+ Implanted AIN

    Institute of Scientific and Technical Information of China (English)

    LI Ming-Kai; LI Cheng-Bin; LIU Chuan-Sheng; FAN Xiang-Jun; FU De-Jun; SHON Yun; KANG Tae-Won

    2004-01-01

    @@ The Ⅲ-Ⅴ wide band gap semiconductors show the potential in applications for dilute magnetic semiconductors.AlN films are implanted with 20-keV Mn+ ions with a dose of 5 × 1016cm-2. The cross section of as-implanted AlN are investigated by field-emission scanning electron microscopy and the energy dispersive spectra. The result confirms that the implantation depth is about 100nm. Cathodoluminescence measurements show the main peak at 2.6eV attributed to a donor-to-Mn2+ transition. It is argued that the Mn element in AlN can act as a p-type dopant peak at 2.07eV. The magnetic measurement shows a transition temperature of 100K in the implanted AlN annealed at 500℃ for 30min. Clear ferromagnetic hysteresis was observed at 77K, with a coercive field of 212.7Oe.

  5. Mn fraction substitutional site and defects induced magnetism in Mn-implanted 6H-SiC

    Energy Technology Data Exchange (ETDEWEB)

    Bouziane, K., E-mail: Khalid.bouziane@uir.ac.ma [Pôle Energies Renouvelables et Etudes Pétrolières, Université Internationale de Rabat, 11000 – Salé el Jadida, Technopolis (Morocco); Al Azri, M.; Elzain, M. [Department of Physics, College of Science, Sultan Qaboos University, P.O. Box 36, Al-Khodh 123 (Oman); Chérif, S.M. [LSPM (CNRS-UPR 3407), Université Paris, 13-Nord, 99, Avenue Jean Baptiste Clément, 93430 Villetaneuse (France); Mamor, M. [Equipe MSISM, Faculté Poly-Disciplinaire, B.P. 4162 Safi, Université Cadi Ayyad, Marrakech (Morocco); Declémy, A. [Institut P’, CNRS – Université de Poitiers – ENSMA, UPR 3346, SP2MI – Téléport 2, 11 boulevard Marie et Pierre Curie, BP 30179, F-86962 Futuroscope Chasseneuil Cedex (France); Thomé, L. [CSNSM-Orsay, Bât. 108, Université d’Orsay, F-91405 Orsay (France)

    2015-05-25

    Highlights: • Shallow Mn-implanted 6H-SiC crystal. • Correlation between Mn-substitutional site concentration and magnetism. • Correlation between defects nature surrounding Mn site and magnetism. • Correlation of magnetism in Mn-doped SiC to Mn at Si sites and vacancy-related defect. - Abstract: n-type 6H-SiC (0 0 0 1) single crystal substrates were implanted with three fluences of manganese (Mn{sup +}) ions: 5 × 10{sup 15}, 1 × 10{sup 16} and 5 × 10{sup 16} cm{sup −2} with implantation energy of 80 keV at 365 °C to stimulate dynamic annealing. The samples were characterized using Rutherford backscattering channeling spectroscopy (RBS/C), high-resolution X-ray diffraction technique (HRXRD), and Superconducting Quantum Interference Device (SQUID) techniques. Two main defect regions have been identified using RBS/C spectra fitted with the McChasy code combined to SRIM simulations. Intermediate defects depth region is associated with vacancies (D{sub V}) and deeper defect (D{sub N}) essentially related to the Si and C interstitial defects. The defect concentration and the maximum perpendicular strain exhibit similar increasing trend with the Mn{sup +} fluence. Furthermore, the amount of Mn atoms at Si substitutional sites and the corresponding magnetic moment per Mn atom were found to increase with increasing Mn fluence from 0.7 μ{sub B} to 1.7 μ{sub B} and then collapsing to 0.2 μ{sub B}. Moreover, a strong correlation has been found between the magnetic moment and the combination of both large D{sub V}/D{sub N} ratio and high Mn at Si sites. These results are corroborated by our ab initio calculations considering the most stable configurations showing that besides the amount of Mn substituting Si sites, local vacancy-rich environment is playing a crucial role in enhancing the magnetism.

  6. Localization and Tracking of Implantable Biomedical Sensors

    Directory of Open Access Journals (Sweden)

    Ilknur Umay

    2017-03-01

    Full Text Available Implantable sensor systems are effective tools for biomedical diagnosis, visualization and treatment of various health conditions, attracting the interest of researchers, as well as healthcare practitioners. These systems efficiently and conveniently provide essential data of the body part being diagnosed, such as gastrointestinal (temperature, pH, pressure parameter values, blood glucose and pressure levels and electrocardiogram data. Such data are first transmitted from the implantable sensor units to an external receiver node or network and then to a central monitoring and control (computer unit for analysis, diagnosis and/or treatment. Implantable sensor units are typically in the form of mobile microrobotic capsules or implanted stationary (body-fixed units. In particular, capsule-based systems have attracted significant research interest recently, with a variety of applications, including endoscopy, microsurgery, drug delivery and biopsy. In such implantable sensor systems, one of the most challenging problems is the accurate localization and tracking of the microrobotic sensor unit (e.g., robotic capsule inside the human body. This article presents a literature review of the existing localization and tracking techniques for robotic implantable sensor systems with their merits and limitations and possible solutions of the proposed localization methods. The article also provides a brief discussion on the connection and cooperation of such techniques with wearable biomedical sensor systems.

  7. Localization and Tracking of Implantable Biomedical Sensors.

    Science.gov (United States)

    Umay, Ilknur; Fidan, Barış; Barshan, Billur

    2017-03-13

    Implantable sensor systems are effective tools for biomedical diagnosis, visualization and treatment of various health conditions, attracting the interest of researchers, as well as healthcare practitioners. These systems efficiently and conveniently provide essential data of the body part being diagnosed, such as gastrointestinal (temperature, pH, pressure) parameter values, blood glucose and pressure levels and electrocardiogram data. Such data are first transmitted from the implantable sensor units to an external receiver node or network and then to a central monitoring and control (computer) unit for analysis, diagnosis and/or treatment. Implantable sensor units are typically in the form of mobile microrobotic capsules or implanted stationary (body-fixed) units. In particular, capsule-based systems have attracted significant research interest recently, with a variety of applications, including endoscopy, microsurgery, drug delivery and biopsy. In such implantable sensor systems, one of the most challenging problems is the accurate localization and tracking of the microrobotic sensor unit (e.g., robotic capsule) inside the human body. This article presents a literature review of the existing localization and tracking techniques for robotic implantable sensor systems with their merits and limitations and possible solutions of the proposed localization methods. The article also provides a brief discussion on the connection and cooperation of such techniques with wearable biomedical sensor systems.

  8. Localization and Tracking of Implantable Biomedical Sensors

    Science.gov (United States)

    Umay, Ilknur; Fidan, Barış; Barshan, Billur

    2017-01-01

    Implantable sensor systems are effective tools for biomedical diagnosis, visualization and treatment of various health conditions, attracting the interest of researchers, as well as healthcare practitioners. These systems efficiently and conveniently provide essential data of the body part being diagnosed, such as gastrointestinal (temperature, pH, pressure) parameter values, blood glucose and pressure levels and electrocardiogram data. Such data are first transmitted from the implantable sensor units to an external receiver node or network and then to a central monitoring and control (computer) unit for analysis, diagnosis and/or treatment. Implantable sensor units are typically in the form of mobile microrobotic capsules or implanted stationary (body-fixed) units. In particular, capsule-based systems have attracted significant research interest recently, with a variety of applications, including endoscopy, microsurgery, drug delivery and biopsy. In such implantable sensor systems, one of the most challenging problems is the accurate localization and tracking of the microrobotic sensor unit (e.g., robotic capsule) inside the human body. This article presents a literature review of the existing localization and tracking techniques for robotic implantable sensor systems with their merits and limitations and possible solutions of the proposed localization methods. The article also provides a brief discussion on the connection and cooperation of such techniques with wearable biomedical sensor systems. PMID:28335384

  9. Paramagnetism in Mn/Fe implanted ZnO

    CERN Document Server

    Gunnlaugsson, HP; Weyer, G; Kobayashi, Y; Bharuth-Ram, K; Olafsson, S; Gislason, H P; Gunnlaugsson, H P; Yoshida, Y; Langouche, G; Molholt, T E; Masenda, H; Johnston, K; Sielemann, R; Dlamini, W B; ISOLDE Collaboration; Naidoo, D; Mantovan, R

    2010-01-01

    Prompted by the generally poor understanding of the nature of magnetic phenomena in 3d-metal doped ZnO, we have undertaken on-line Fe-57 Mossbauer spectroscopy on ZnO single crystals in an external magnetic field of 0.6 T, following the implantation of radioactive Mn-57 ions at room temperature. The Mossbauer spectra of the dilute Fe impurities are dominated by sextets whose angular dependence rules out an ordered magnetic state (which had been previously proposed) but are well accounted for on the basis of Fe3+ paramagnetic centers on substitutional Zn sites with unusually long relaxation times (> 20 ns). (C) 2010 American Institute of Physics. {[}doi:10.1063/1.3490708

  10. Golgi localized barley MTP8 proteins facilitate Mn transport.

    Science.gov (United States)

    Pedas, Pai; Schiller Stokholm, Michaela; Hegelund, Josefine Nymark; Ladegård, Anne Hald; Schjoerring, Jan Kofod; Husted, Søren

    2014-01-01

    Many metabolic processes in plants are regulated by manganese (Mn) but limited information is available on the molecular mechanisms controlling cellular Mn homeostasis. In this study, a yeast assay was used to isolate and characterize two genes, MTP8.1 and MTP8.2, which encode membrane-bound proteins belonging to the cation diffusion facilitator (CDF) family in the cereal species barley (Hordeum vulgare). Transient expression in onion epidermal cells showed that MTP8.1 and MTP8.2 proteins fused to the green fluorescent protein (GFP) are localized to Golgi. When heterologously expressed in yeast, MTP8.1 and MTP8.2 were found to be Mn transporters catalysing Mn efflux in a similar manner as the Golgi localized endogenous yeast protein Pmr1p. The level of MTP8.1 transcripts in barley roots increased with external Mn supply ranging from deficiency to toxicity, while MTP8.2 transcripts decreased under the same conditions, indicating non-overlapping functions for the two genes. In barley leaves, the expression of both MTP8 genes declined in response to toxic Mn additions to the roots suggesting a role in ensuring proper delivery of Mn to Golgi. Based on the above we suggest that barley MTP8 proteins are involved in Mn loading to the Golgi apparatus and play a role in Mn homeostasis by delivering Mn to Mn-dependent enzymes and/or by facilitating Mn efflux via secretory vesicles. This study highlights the importance of MTP transporters in Mn homeostasis and is the first report of Golgi localized Mn2+ transport proteins in a monocot plant species.

  11. Golgi localized barley MTP8 proteins facilitate Mn transport.

    Directory of Open Access Journals (Sweden)

    Pai Pedas

    Full Text Available Many metabolic processes in plants are regulated by manganese (Mn but limited information is available on the molecular mechanisms controlling cellular Mn homeostasis. In this study, a yeast assay was used to isolate and characterize two genes, MTP8.1 and MTP8.2, which encode membrane-bound proteins belonging to the cation diffusion facilitator (CDF family in the cereal species barley (Hordeum vulgare. Transient expression in onion epidermal cells showed that MTP8.1 and MTP8.2 proteins fused to the green fluorescent protein (GFP are localized to Golgi. When heterologously expressed in yeast, MTP8.1 and MTP8.2 were found to be Mn transporters catalysing Mn efflux in a similar manner as the Golgi localized endogenous yeast protein Pmr1p. The level of MTP8.1 transcripts in barley roots increased with external Mn supply ranging from deficiency to toxicity, while MTP8.2 transcripts decreased under the same conditions, indicating non-overlapping functions for the two genes. In barley leaves, the expression of both MTP8 genes declined in response to toxic Mn additions to the roots suggesting a role in ensuring proper delivery of Mn to Golgi. Based on the above we suggest that barley MTP8 proteins are involved in Mn loading to the Golgi apparatus and play a role in Mn homeostasis by delivering Mn to Mn-dependent enzymes and/or by facilitating Mn efflux via secretory vesicles. This study highlights the importance of MTP transporters in Mn homeostasis and is the first report of Golgi localized Mn2+ transport proteins in a monocot plant species.

  12. Local Structure and Magnetism of (Ga,Mn)As

    CERN Document Server

    AUTHOR|(CDS)2093111; Temst, Kristiaan

    Throughout the years, dilute magnetic semiconductors (DMS) have emerged as promising materials for semiconductor-based spintronics. In particular, (Ga,Mn)As has become the model system in which to explore the physics of carrier-mediated ferromagnetism in semiconductors and the associated spintronic phenomena, with a number of interesting functionalities and demonstrated proof-of-concept devices. It constitutes the perfect example of how the magnetic behavior of DMS materials is strongly influenced by local structure. In this thesis, we address key aspects of the interplay between local structure and ferromagnetism of (Ga,Mn)As. We unambiguously identify the lattice site occupied by interstitial Mn as the tetrahedral interstitial site with As nearest neighbors T(As). We show, furthermore, that the T(As) is the most energetically favorable site regardless of the interstitial atom forming or not complexes with substitutional Mn. We also evaluate the thermal stability of both interstitial and substitutional Mn si...

  13. Fourier analysis on local fields (MN-15)

    CERN Document Server

    Taibleson, M H

    2015-01-01

    This book presents a development of the basic facts about harmonic analysis on local fields and the n-dimensional vector spaces over these fields. It focuses almost exclusively on the analogy between the local field and Euclidean cases, with respect to the form of statements, the manner of proof, and the variety of applications. The force of the analogy between the local field and Euclidean cases rests in the relationship of the field structures that underlie the respective cases. A complete classification of locally compact, non-discrete fields gives us two examples of connected fields (rea

  14. Pulsed laser irradiation-induced microstructures in the Mn ion implanted Si

    Energy Technology Data Exchange (ETDEWEB)

    Naito, Muneyuki, E-mail: naito22@center.konan-u.ac.jp [Department of Chemistry, Konan University, Okamoto, Higashi-Nada, Kobe, Hyogo 658-8501 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi, Saitama 332-0012 (Japan); Yamada, Ryo; Machida, Nobuya [Department of Chemistry, Konan University, Okamoto, Higashi-Nada, Kobe, Hyogo 658-8501 (Japan); Koshiba, Yusuke; Sugimura, Akira; Aoki, Tamao; Umezu, Ikurou [Department of Physics, Konan University, Okamoto, Higashi-Nada, Kobe, Hyogo 658-8501 (Japan)

    2015-12-15

    We have examined microstructures induced by pulsed-laser-melting for the Mn ion implanted Si using transmission electron microscopy. Single crystalline Si(0 0 1) wafers were irradiated with 65 keV and 120 keV Mn ions to a fluence of 1.0 × 10{sup 16}/cm{sup 2} at room temperature. The ion beam-induced amorphous layers in the as-implanted samples were melted and resolidified by pulsed YAG laser irradiation. After laser irradiation with appropriate laser fluence, the surface amorphous layers recrystallize into the single crystalline Si. The Mn concentration becomes higher in the near-surface region with increasing the number of laser shots. The migrated Mn atoms react with Si atoms and form the amorphous Mn–Si in the Si matrix.

  15. Exposed Dental Implant? Local Autograft A Saviour!

    Science.gov (United States)

    Rai, Raj; Punde, Prashant A; Suryavanshi, Harshal; Shree, Swetha

    2015-01-01

    Implant exposure due to faulty placement, posses as the most common reason for implant failure. The implant placed too close to buccal or lingual cortex have lead to such failure on numerous occasions. Also, anatomic variations like the thin buccolingual width of alveolar ridge predispose exposure of the implant. 25-year-old female patient had undergone surgical placement of implants in mandibular anterior region 2 months back in the private dental clinic. The clinician noted Grade I mobility in one of the implants placed. The case was referred to the author. Thin overlying gingiva depicted an entire buccal aspect of the implant, which suggested more than 90 % loss of buccal cortex. According to literature and review of similar case reports, the only way suggested was to surgically remove the implant and wait for 12-24 months for the bone to heal for subsequent placement. Rather than the removal of implants as suggested, the author followed a naval approach of reinforcing buccal cortex using an autogenous cortical block from mandibular symphysis. The reinforcement surgery had certainly saved patients time, money and most importantly limits a crucial period of edentulism, which may be enforced on a patient in case the implant was removed. PMID:26668490

  16. Local complications after cosmetic breast implant surgery in Finland

    DEFF Research Database (Denmark)

    Kulmala, Ilona; McLaughlin, Joseph K; Pakkanen, Matti

    2004-01-01

    cosmetic silicone breast implants between 1968 and 2002. Patient records were abstracted, and additional information was gathered using a structured questionnaire that was mailed to 470 of the women in the cohort. Overall, 36% of the women had 1 or more diagnoses of postoperative complications...... implantation. Most of the women were satisfied with the implantation, but only 40% considered the preoperative information on possible risks related to implantation as sufficient. With respect to the occurrence of local complications following cosmetic breast implantation, the findings of this study...

  17. High performance hydrogen sensor based on Mn implanted ZnO nanowires array fabricated on ITO substrate.

    Science.gov (United States)

    Renitta, A; Vijayalakshmi, K

    2017-08-01

    In the present research, we propose a novel approach for the detection of hydrogen gas using Mn implanted ZnO nanowires fabricated onto ITO coated glass substrate by chemical spray pyrolysis deposition. The effect of Mn concentration on the structural, optical and morphological properties of ZnO films were investigated. X-ray diffraction studies showed that the Mn implanted ZnO films were grown as a polycrystalline hexagonal wurtzite phase without any impurities. The (101) peak position of ZnO-Mn films was shifted towards a lower angle with increasing Mn concentration. The optical band gap decreased from 3.45eV to 3.23eV with increasing Mn content. PL spectra, revealed sharp and strong near band edge emission which suggests that ZnO nanowires exhibit high crystalline quality. FE-SEM images of Mn implanted ZnO show perfectly aligned nanowires for all the films fabricated on ITO. The material (Zn, O, Mn) was confirmed by EDX spectra. The hydrogen sensing mechanism of the Mn implanted ZnO nanowire sensor was also discussed. It was found that H2 response was significantly enhanced by more than one order of magnitude with increasing Mn doping concentrations. The studied ZnO-Mn films coated on ITO substrate can be used as a low cost and easy-fabrication hydrogen sensing material. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Temperature and dose dependence of defect complex formation with ion implanted Mn/Fe in ZnO

    CERN Document Server

    Mølholt, T E; Gunnlaugsson, H P; Bharuth-Ram, K; Fanciulli, M; Gíslason, H P; Johnston, K; Kobayashi, Y; Langouche, G; Masenda, H; Naidoo, D; Ólafsson, S; Sielemann, R; Weyer, G

    2009-01-01

    57Fe Mössbauer spectroscopy following ion implantation of radioactive 57Mn+ ( T1/2=85.4 s) has been applied to study the formation of Fe/Mn implantation-induced defects in ZnO at temperatures between 319 and 390 K. The formation of ferric iron–vacancy complexes is found to depend strongly on the implanted dose and to be faster and more efficient at higher temperatures. The results at these temperatures suggest the mobility of the Zn vacancy, together with vacancy trapping at the substitutional Mn/Fe impurities are responsible for the formation of Fe–VZn complexes

  19. LOCAL COMPLICATIONS OCCURRING DURING DENTAL IMPLANTATION

    Directory of Open Access Journals (Sweden)

    Tihomir Georgiev

    2010-11-01

    Full Text Available With regard to the emergence of new concepts in dental treatment involving placement of dental implants and the significance of therapeutic treatment of the intrusion in their complications. The purpose of the article is to make a review of the problems and to point out options for their treatment.

  20. Damage annealing in low temperature Fe/Mn implanted ZnO

    Energy Technology Data Exchange (ETDEWEB)

    Gunnlaugsson, H. P. [University of Aarhus, Department of Physics and Astronomy (Denmark); Bharuth-Ram, K., E-mail: kbr@tlabs.ac.za [Durban University of Technology, Physics Department (South Africa); Johnston, K. [PH Department, ISOLDE/CERN (Switzerland); Langouche, G. [University of Leuven, Instituut voor Kern-en Stralings fysika (Belgium); Mantovan, R. [Laboratorio MDM, IMM-CNR (Italy); Mølholt, T. E. [University of Iceland, Science Institute (Iceland); Naidoo, D. [University of the Witwatersrand, School of Physics (South Africa); Ólafsson, O. [University of Iceland, Science Institute (Iceland); Weyer, G. [University of Aarhus, Department of Physics and Astronomy (Denmark)

    2015-04-15

    {sup 57}Fe Emission Mössbauer spectra obtained after low fluence (<10{sup 12} cm {sup −2}) implantation of {sup 57}Mn (T{sub 1/2}= 1.5 min.) into ZnO single crystal held at temperatures below room temperature (RT) are presented. The spectra can be analysed in terms of four components due to Fe {sup 2+} and Fe {sup 3+} on Zn sites, interstitial Fe and Fe in damage regions (Fe {sub D}). The Fe {sub D} component is found to be indistinguishable from similar component observed in emission Mössbauer spectra of higher fluence (∼10{sup 15} cm {sup −2}){sup 57}Fe/ {sup 57}Co implanted ZnO and {sup 57}Fe implanted ZnO, demonstrating that the nature of the damage regions in the two types of experiments is similar. The defect component observed in the low temperature regime was found to anneal below RT.

  1. Magnetic Characteristics of Mn-Implanted GaN Nanorods Followed by Thermal Annealing

    Directory of Open Access Journals (Sweden)

    Im Taek Yoon

    2012-01-01

    Full Text Available We have investigated the magnetic and optical properties of dislocation-free vertical GaN nanorods with diameters of 150 nm grown on (111 Si substrates by radio-frequency plasma-assisted molecular-beam epitaxy followed by Mn ion implantation and annealing. The GaN nanorods are fully relaxed and have a very good crystal quality characterized by extremely strong and narrow photoluminescence excitonic lines near 3.47 eV. For GaMnN nanorods, it can be concluded that the ferromagnetic property of GaMnN nanorod with a Curie temperature over 300 K is associated with the formation of Mn4Si7 magnetic phase which results from the effects of magnetic and structural disorder introduced by a random incorporation and inhomogeneous distribution of Mn atoms in the porous layer between the nanorods that form precipitates in the Si substrate before or during the annealing step amongst the GaN nanorods.

  2. Magnetoresistance in Mn ion-implanted GaAs:Zn nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Paschoal, W.; Kumar, Sandeep; Jain, V.; Pettersson, H., E-mail: hakan.pettersson@hh.se [Solid State Physics/The Nanometer Structure Consortium, Lund University, Box 118, SE-221 00 Lund (Sweden); Department of Mathematics, Physics and Electrical Engineering, Halmstad University, Box 823, SE-301 18, Halmstad (Sweden); Jacobsson, D.; Samuelson, L. [Solid State Physics/The Nanometer Structure Consortium, Lund University, Box 118, SE-221 00 Lund (Sweden); Johannes, A.; Ronning, C. [Institute for Solid State Physics, Friedrich-Schiller-University Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Canali, C. M.; Pertsova, A. [Department of Physics and Electrical Engineering, Linneaus University, SE-39233 Kalmar (Sweden); Dick, K. A. [Solid State Physics/The Nanometer Structure Consortium, Lund University, Box 118, SE-221 00 Lund (Sweden); Center for Analysis and Synthesis, Lund University, Box 124, S-221 00 Lund (Sweden)

    2014-04-14

    We have investigated the magnetoresistance (MR) in a series of Zn doped (p-type) GaAs nanowires implanted with different Mn concentrations. The nanowires with the lowest Mn concentration (∼0.0001%) exhibit a low resistance of a few kΩ at 300 K and a 4% positive MR at 1.6 K, which can be well described by invoking a spin-split subband model. In contrast, nanowires with the highest Mn concentration (4%) display a large resistance of several MΩ at 300 K and a large negative MR of 85% at 1.6 K. The large negative MR is interpreted in terms of spin-dependent hopping in a complex magnetic nanowire landscape of magnetic polarons, separated by intermediate regions of Mn impurity spins. Sweeping the magnetic field back and forth for the 4% sample reveals a hysteresis that indicates the presence of a weak ferromagnetic phase. We propose co-doping with Zn to be a promising way to reach the goal of realizing ferromagnetic Ga{sub 1−x}Mn{sub x}As nanowires for future nanospintronics.

  3. Local Cellular Responses to Titanium Dioxide from Orthopedic Implants

    Directory of Open Access Journals (Sweden)

    Jie J. Yao

    2017-07-01

    Full Text Available We evaluated recently published articles relevant to the biological effects of titanium dioxide (TiO2 particles on local endogenous cells required for normal bone homeostasis, repair, and implant osseointegration. Structural characteristics, size, stability, and agglomeration of TiO2 particles alter the viability and behavior of multiple bone-related cell types. Resulting shifts in bone homeostasis may increase bone resorption and lead to clinical incidents of osteolysis, implant loosening, and joint pain. TiO2 particles that enter cells (through endocytosis or Trojan horse mechanism may further disrupt implant retention. We propose that cellular responses to titanium-based nanoparticles contribute to pathological mechanisms underlying the aseptic loosening of titanium-based metal implants.

  4. [PRIMARY STUDY ON IMPLANT COVERAGE WITH LOCAL SOFT TISSUE IN IMMEDIATE IMPLANT-BASED BREAST RECONSTRUCTION].

    Science.gov (United States)

    Li, Guangxue; Mu, Lan; Liu, Yan; Yang, Kai; Peng, Zhe; Bi, Ye

    2016-03-01

    To explore the method of implant coverage with local soft tissue in immediate implant-based breast reconstruction and to evaluate the early effectiveness. Between April 2014 and August 2015, 11 patients with breast cancer underwent immediate breast reconstruction with implants after mastectomy, and the clinical data were reviewed retrospectively. The age ranged 29-48 years (mean, 36 years). The disease duration was from 7 days to 12 months (median, 3 months). According to tumor staging, 3 cases were rated as T(is)N0M0, 4 cases as T1N0M0, and 4 cases as T2N0M0. The implants were covered with local soft tissue according to the volume of mastectomy and contralateral breast size, including pectoralis major myocutaneous flaps with inframammary adipofasical flaps (3 cases), with serratus anterior fascial flap (5 cases), with rectus sheath fascial flap (1 case), and with serratus anterior fascial flap and rectus sheath fascial flap (2 cases). The size of pectoralis major myocutaneous flaps ranged from 15 cm x 9 cm to 20 cm x 15 cm, and the serratus anterior fascial flaps from 10 cm x 8 cm to 15 cm x 10 cm, and the rectus sheath fascial flap from 8 cm x 6 cm to 10 cm x 8 cm. One patient had partial nipple necrosis postoperatively and was cured, and no other postoperative complications of hematoma, infection, or implant exposure was found. The patients were followed up 4-13 months (median, 8 months). The reconstructive outcomes were excellent in 10 cases and good in 1 case, with an excellent and good rate of 100%. During follow-up, no rupture or exposure of the implant was observed; capsular contracture (Baker grade II) occurred in 1 case. Adequate coverage of implants with different local soft tissue flaps can achieve satisfactory early effectiveness in immediate implant-based breast reconstruction after mastectomy.

  5. Magnetic and structural properties of Fe, Ni, and Mn-implanted SiC

    CERN Document Server

    Theodoropoulou, N; Chu, S N G; Overberg, M E; Abernathy, C R; Pearton, S J; Wilson, R G; Zavada, J M; Park, Y D

    2002-01-01

    Direct implantation of Fe, Ni or Mn at doses of 3-5x10 sup 1 sup 6 cm sup - sup 2 into p-type 6H-SiC substrates was carried out at a sample temperature of approx 350 deg. C. Subsequent annealing was performed at 700-1000 deg. C for 5 mins. Residual damage in the form of end-of-range defects and dislocation loops in the region from the surface to a depth of approx 0.20 mu m were examined by transmission electron microscopy. To the sensitivity of both x-ray diffraction and selected area diffraction pattern analysis, no secondary phases could be detected. Signatures of ferromagnetism were observed in all the highest dose samples, with apparent Curie temperatures of 50 K (Ni), 250 K (Mn), and 270 K (Fe).

  6. Room temperature ferromagnetism in low dose ion implanted counter-doped Ge:Mn, As

    Science.gov (United States)

    Donarelli, M.; Kazakova, O.; Ortolani, L.; Morandi, V.; Impellizzeri, G.; Priolo, F.; Passacantando, M.; Ottaviano, L.

    2017-10-01

    We demonstrate room-temperature ferromagnetism in germanium counter-doped with manganese and arsenic at concentrations up to approximately 2.1 × 1020 at/cm3: these values are one order of magnitude lower than those at which ferromagnetic behavior has previously been observed. Synthesis proceeded by ion implantation at 513 K followed by annealing in argon at 673 K. High resolution TEM, STEM, and EDX show single-phase diamond cubic material lacking Mn or As precipitates. These findings are consistent with the prediction of Chen et al. that counter-doping with approximately equal concentrations of a single-electron donor permits Mn, a two-electron acceptor, to be incorporated at high enough concentrations to yield a diluted magnetic semiconductor with a Curie temperature above room temperature.

  7. Characterization of High Dose Mn, Fe, and Ni implantation into p-GaN

    CERN Document Server

    Pearton, S J; Thaler, G; Abernathy, C R; Theodoropoulou, N; Hebard, A F; Chu, S N G; Wilson, R G; Zavada, J M; Polyakov, A Y; Osinsky, A V; Norris, P E; Chow, P P; Wowchack, A M; Hove, J M V; Park, Y D

    2002-01-01

    The magnetization of p-GaN or p-AlGaN/GaN superlattices was measured after implantation with high doses (3-5x10 sup 1 sup 6 cm sup - sup 2) of Mn, Fe, or Ni and subsequent annealing at 700-1000 deg. C. The samples showed ferromagnetic contributions below temperatures ranging from 190-250 K for Mn to 45-185 K for Ni and 80-250 K for Fe. The use of superlattices to enhance the hole concentration did not produce any change in ferromagnetic ordering temperature. No secondary phase formation was observed by x-ray diffraction, transmission electron microscopy, or selected area diffraction pattern analysis for the doses we employed.

  8. Towards quantifying cochlear implant localization performance in complex acoustic environments.

    Science.gov (United States)

    Kerber, S; Seeber, B U

    2011-08-01

    Cochlear implant (CI) users frequently report listening difficulties in reverberant and noisy spaces. While it is common to assess speech understanding with implants in background noise, binaural hearing performance has rarely been quantified in the presence of other sources, although the binaural system is a major contributor to the robustness of speech understanding in noisy situations with normal hearing. Here, a pointing task was used to measure horizontal localization ability of a bilateral CI user in quiet and in a continuous diffuse noise interferer at a signal-to-noise ratio of 0 dB. Results were compared to localization performance of six normal hearing listeners. The average localization error of the normal hearing listeners was within normal ranges reported previously and only increased by 1.8° when the interfering noise was introduced. In contrast, the bilateral CI user showed a localization error of 22° in quiet which rose to 31° in noise. This increase was partly due to target sounds being inaudible when presented from frontal locations between -20° and +20°. With the noise present, the implant user was only able to reliably hear target sounds presented from locations well off the median plane. The results give support to the informal complaints raised by CI users and can help to define targets for the design of, e.g., noise reduction algorithms for implant processors.

  9. Effects of local melatonin application on implant osseointegration.

    Science.gov (United States)

    Tresguerres, Isabel F; Clemente, Celia; Blanco, Luis; Khraisat, Ameen; Tamimi, Faleh; Tresguerres, Jesús A F

    2012-06-01

    The aim of this study was to assess the effect of local melatonin administration on bone osseointegration around implants in rabbit tibiae. Ten female, 6-month-old New Zealand rabbits were randomly divided into two groups: the experimental group, where five rabbits were treated with local application of melatonin (3 mg) to implant sites when placed into the rabbit tibia, and the control group, those who where without additive materials. Four weeks later, animals were sacrificed; tibiae were dissected from soft tissues and fixed in buffered formaldehyde, and then included in methacrylate. Histological sections were performed to be studied under light microscopy and analyzed morphometrically to evaluate the amount of bone to implant contact (BIC), trabecular area density, and cortical area density. One-way analysis of variance test was used for statistical evaluation. p < .05 was considered to be significant. Histological evaluation showed more trabecular reaction in the melatonin group. Morphometrical analysis showed a statistically significant increase in trabecular BIC in the melatonin group when compared with the control group (24.61% ± 2.87 vs 13.62% ± 1.44; p < .01). Cortical BIC was decreased in the melatonin group, without statistical significance (71.08 ± 3.63 vs 76.28 ± 2.57; p = 0.31). Trabecular area density was increased significantly in the melatonin group (8.68 ± 1.61 vs 4.02 ± 0.36; p < .05). Cortical area density was decreased significantly in the melatonin group (91.31 ± 1.6 vs 95.7 ± 0.5; p < .05). Within the limitation of this animal study, local melatonin application at the time of implant placement might induce more trabecular bone at implant contact and higher trabecular area density. © 2010 Wiley Periodicals, Inc.

  10. Implantable magnetic nanocomposites for the localized treatment of breast cancer

    Science.gov (United States)

    Kan-Dapaah, Kwabena; Rahbar, Nima; Soboyejo, Wole

    2014-12-01

    This paper explores the potential of implantable magnetic nanocomposites for the localized treatment of breast cancer via hyperthermia. Magnetite (Fe3O4)-reinforced polydimethylsiloxane composites were fabricated and characterized to determine their structural, magnetic, and thermal properties. The thermal properties and degree of optimization were shown to be strongly dependent on material properties of magnetic nanoparticles (MNPs). The in-vivo temperature profiles and thermal doses were investigated by the use of a 3D finite element method (FEM) model to simulate the heating of breast tissue. Heat generation was calculated using the linear response theory model. The 3D FEM model was used to investigate the effects of MNP volume fraction, nanocomposite geometry, and treatment parameters on thermal profiles. The implications of the results were then discussed for the development of implantable devices for the localized treatment of breast cancer.

  11. L'etude de l'InP et du GaP suite a l'implantation ionique de Mn et a un recuit thermique

    Science.gov (United States)

    Bucsa, Ioan Gigel

    Cette these est dediee a l'etude des materiaux InMnP et GaMnP fabriques par implantation ionique et recuit thermique. Plus precisement nous avons investigue la possibilite de former par implantation ionique des materiaux homogenes (alliages) de InMnP et GaMnP contenant de 1 a 5 % atomiques de Mn qui seraient en etat ferromagnetique, pour des possibles applications dans la spintronique. Dans un premier chapitre introductif nous donnons les motivations de cette recherche et faisons une revue de la litterature sur ce sujet. Le deuxieme chapitre decrit les principes de l'implantation ionique, qui est la technique utilisee pour la fabrication des echantillons. Les effets de l'energie, fluence et direction du faisceau ionique sur le profil d'implantation et la formation des dommages seront mis en evidence. Aussi dans ce chapitre nous allons trouver des informations sur les substrats utilises pour l'implantation. Les techniques experimentales utilisees pour la caracterisation structurale, chimique et magnetique des echantillons, ainsi que leurs limitations sont presentees dans le troisieme chapitre. Quelques principes theoriques du magnetisme necessaires pour la comprehension des mesures magnetiques se retrouvent dans le chapitre 4. Le cinquieme chapitre est dedie a l'etude de la morphologie et des proprietes magnetiques des substrats utilises pour implantation et le sixieme chapitre, a l'etude des echantillons implantes au Mn sans avoir subi un recuit thermique. Notamment nous allons voir dans ce chapitre que l'implantation de Mn a plus que 1016 ions/cm 2 amorphise la partie implantee du materiau et le Mn implante se dispose en profondeur sur un profil gaussien. De point de vue magnetique les atomes implantes se trouvent dans un etat paramagnetique entre 5 et 300 K ayant le spin 5/2. Dans le chapitre 7 nous presentons les proprietes des echantillons recuits a basses temperatures. Nous allons voir que dans ces echantillons la couche implantee est polycristalline et les

  12. Sound localization ability of young children with bilateral cochlear implants.

    NARCIS (Netherlands)

    Beijen, J.W.; Snik, A.F.M.; Mylanus, E.A.M.

    2007-01-01

    OBJECTIVE: To evaluate the benefit of bilateral cochlear implantation in young children. STUDY DESIGN: Clinical trial comparing a group of bilaterally implanted children with a group of unilaterally implanted children. SETTING: Tertiary referral center. PATIENTS: Five bilaterally implanted children

  13. Implants delivering bisphosphonate locally increase periprosthetic bone density in an osteoporotic sheep model. A pilot study

    Directory of Open Access Journals (Sweden)

    GVA Stadelmann

    2008-07-01

    Full Text Available It is a clinical challenge to obtain a sufficient orthopaedic implant fixation in weak osteoporotic bone. When the primary implant fixation is poor, micromotions occur at the bone-implant interface, activating osteoclasts, which leads to implant loosening. Bisphosphonate can be used to prevent the osteoclastic response, but when administered systemically its bioavailability is low and the time it takes for the drug to reach the periprosthetic bone may be a limiting factor. Recent data has shown that delivering bisphosphonate locally from the implant surface could be an interesting solution. Local bisphosphonate delivery increased periprosthetic bone density, which leads to a stronger implant fixation, as demonstrated in rats by the increased implant pullout force. The aim of the present study was to verify the positive effect on periprosthetic bone remodelling of local bisphosphonate delivery in an osteoporotic sheep model. Four implants coated with zoledronate and two control implants were inserted in the femoral condyle of ovariectomized sheep for 4 weeks. The bone at the implant surface was 50% higher in the zoledronate-group compared to control group. This effect was significant up to a distance of 400µm from the implant surface. The presented results are similar to what was observed in the osteoporotic rat model, which suggest that the concept of releasing zoledronate locally from the implant to increase the implant fixation is not species specific. The results of this trial study support the claim that local zoledronate could increase the fixation of an implant in weak bone.

  14. Golgi localized barley MTP8 proteins facilitate Mn transport

    DEFF Research Database (Denmark)

    Pedas, Pai Rosager; Schiller, Michaela; Hegelund, Josefine Nymark

    2014-01-01

    Many metabolic processes in plants are regulated by manganese (Mn) but limited information is available on the molecular mechanisms controlling cellular Mn homeostasis. In this study, a yeast assay was used to isolate and characterize two genes, MTP8.1 and MTP8.2 , which encode membrane-bound pro......Many metabolic processes in plants are regulated by manganese (Mn) but limited information is available on the molecular mechanisms controlling cellular Mn homeostasis. In this study, a yeast assay was used to isolate and characterize two genes, MTP8.1 and MTP8.2 , which encode membrane...... in yeast, MTP8.1 and MTP8.2 were found to be Mn transporters catalysing Mn efflux in a similar manner as the Golgi localized endogenous yeast protein Pmr1p. The level of MTP8.1 transcripts in barley roots increased with external Mn supply ranging from deficiency to toxicity, while MTP8.2 transcripts...... decreased under the same conditions, indicating non-overlapping functions for the two genes. In barley leaves, the expression of both MTP8 genes declined in response to toxic Mn additions to the roots suggesting a role in ensuring proper delivery of Mn to Golgi. Based on the above we suggest that barley MTP...

  15. Emission Mössbauer spectroscopy study of fluence dependence of paramagnetic relaxation in Mn/Fe implanted ZnO

    Science.gov (United States)

    Masenda, H.; Geburt, S.; Bharuth-Ram, K.; Naidoo, D.; Gunnlaugsson, H. P.; Johnston, K.; Mantovan, R.; Mølholt, T. E.; Ncube, M.; Shayestehaminzadeh, S.; Gislason, H. P.; Langouche, G.; Ólafsson, S.; Ronning, C.

    2016-12-01

    Emission Mössbauer Spectroscopy following the implantation of radioactive precursor isotope 57Mn+ ( T 1/2= 1.5 min) into ZnO single crystals at ISOLDE/CERN shows that a large fraction of 57Fe atoms produced in the 57Mn beta decay is created as paramagnetic Fe3+ with relatively long spin-lattice relaxation times. Here we report on ZnO pre-implanted with 56Fe to fluences of 2×1013, 5×10 13 and 8 × 1013 ions/cm2 in order to investigate the dependence of the paramagnetic relaxation rate of Fe3+ on fluence. The spectra are dominated by magnetic features displaying paramagnetic relaxation effects. The extracted spin-lattice relaxation rates show a slight increase with increasing ion fluence at corresponding temperatures and the area fraction of Fe3+ at room temperature reaches a maximum contribution of 80(3)% in the studied fluence range.

  16. Effects of local administration of growth hormone in peri-implant bone: an experimental study with implants in rabbit tibiae.

    Science.gov (United States)

    Tresguerres, Isabel F; Blanco, Luis; Clemente, Celia; Tresguerres, Jesús A F

    2003-01-01

    The objective of this study was to evaluate the qualitative and quantitative differences that could appear in newly formed peri-implant bone around Screw-Vent implants placed in rabbit tibiae when treated with local administration of growth hormone (GH). Eight New Zealand rabbits were randomly divided into 2 groups: the experimental group, which received 4 IU of GH in the form of lyophilized powder added to the ostectomy site before implant placement, and the control group, which did not receive GH before implant placement. Animals were sacrificed 2 weeks later, and histologic sections were obtained for histomorphometry and observation under light microscopy. The sections in the GH-treated group presented enhanced growth of new trabeculae from the periosteal tissue, and the bone-to-implant contact in the experimental group was significantly greater (P < .05). Local administration of GH stimulated a more dramatic effect than that seen previously with systemic GH administration, prompting growth from both the periosteum and endosteum. Local administration of GH at the time of implant placement could enhance peri-implant bone reaction.

  17. Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration

    Science.gov (United States)

    McConnell, George C.; Rees, Howard D.; Levey, Allan I.; Gutekunst, Claire-Anne; Gross, Robert E.; Bellamkonda, Ravi V.

    2009-10-01

    Prosthetic devices that are controlled by intracortical electrodes recording one's 'thoughts' are a reality today, and no longer merely in the realm of science fiction. However, widespread clinical use of implanted electrodes is hampered by a lack of reliability in chronic recordings, independent of the type of electrodes used. One major hypothesis has been that astroglial scar electrically impedes the electrodes. However, there is a temporal discrepancy between stabilization of scar's electrical properties and recording failure with recording failure lagging by 1 month. In this study, we test a possible explanation for this discrepancy: the hypothesis that chronic inflammation, due to the persistent presence of the electrode, causes a local neurodegenerative state in the immediate vicinity of the electrode. Through modulation of chronic inflammation via stab wound, electrode geometry and age-matched control, we found that after 16 weeks, animals with an increased level of chronic inflammation were associated with increased neuronal and dendritic, but not axonal, loss. We observed increased neuronal and dendritic loss 16 weeks after implantation compared to 8 weeks after implantation, suggesting that the local neurodegenerative state is progressive. After 16 weeks, we observed axonal pathology in the form of hyperphosphorylation of the protein tau in the immediate vicinity of the microelectrodes (as observed in Alzheimer's disease and other tauopathies). The results of this study suggest that a local, late onset neurodegenerative disease-like state surrounds the chronic electrodes and is a potential cause for chronic recording failure. These results also inform strategies to enhance our capability to attain reliable long-term recordings from implantable electrodes in the CNS.

  18. Pressure-induced transition from localized electron toward band antiferromagnetism in LaMnO(3).

    Science.gov (United States)

    Zhou, J-S; Goodenough, J B

    2002-08-19

    The temperature dependence of the ac susceptibility under pressure has been used to track the Néel temperature T(N) of the Mott insulators LaMnO3, CaMnO3, and YCrO3. Bloch's rule relating T(N) to volume V, viz., alpha=dlog(T(N)/dlog(V=-3.3, is obeyed in YCrO3 and CaMnO3; it fails in LaMnO3. This breakdown is interpreted to be due to a sharp increase in the factor [U(-1)+(2Delta)(-1)] entering the superexchange perturbation formula. A first-order change at 7 kbar indicates that the transition from localized-electron to band magnetism is not smooth.

  19. From micro- to nanostructured implantable device for local anesthetic delivery.

    Science.gov (United States)

    Zorzetto, Laura; Brambilla, Paola; Marcello, Elena; Bloise, Nora; De Gregori, Manuela; Cobianchi, Lorenzo; Peloso, Andrea; Allegri, Massimo; Visai, Livia; Petrini, Paola

    2016-01-01

    Local anesthetics block the transmission of painful stimuli to the brain by acting on ion channels of nociceptor fibers, and find application in the management of acute and chronic pain. Despite the key role they play in modern medicine, their cardio and neurotoxicity (together with their short half-life) stress the need for developing implantable devices for tailored local drug release, with the aim of counterbalancing their side effects and prolonging their pharmacological activity. This review discusses the evolution of the physical forms of local anesthetic delivery systems during the past decades. Depending on the use of different biocompatible materials (degradable polyesters, thermosensitive hydrogels, and liposomes and hydrogels from natural polymers) and manufacturing processes, these systems can be classified as films or micro- or nanostructured devices. We analyze and summarize the production techniques according to this classification, focusing on their relative advantages and disadvantages. The most relevant trend reported in this work highlights the effort of moving from microstructured to nanostructured systems, with the aim of reaching a scale comparable to the biological environment. Improved intracellular penetration compared to microstructured systems, indeed, provides specific drug absorption into the targeted tissue and can lead to an enhancement of its bioavailability and retention time. Nanostructured systems are realized by the modification of existing manufacturing processes (interfacial deposition and nanoprecipitation for degradable polyester particles and high- or low-temperature homogenization for liposomes) or development of novel strategies (electrospun matrices and nanogels). The high surface-to-volume ratio that characterizes nanostructured devices often leads to a burst drug release. This drawback needs to be addressed to fully exploit the advantage of the interaction between the target tissues and the drug: possible strategies

  20. Local symmetry lowering in CdMn{sub 2}O{sub 4} spinel

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, G. N. P.; Lopes, A. M. L., E-mail: armandina.lima.lopes@cern.ch [CFNUL - Centro de Física Nuclear, Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IFIMUP and IN-Institute of Nanoscience and Nanotechnology, Departamento de Física e Astronomia da Faculdade de Ciências da Universidade do Porto, Rua do Campo Alegre, 687, 4169-007 Porto (Portugal); Teixeira, R.; Silva, M. R. [CFNUL - Centro de Física Nuclear, Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Mendonça, T. M.; Araújo, J. P., E-mail: jearaujo@fc.up.pt [IFIMUP and IN-Institute of Nanoscience and Nanotechnology, Departamento de Física e Astronomia da Faculdade de Ciências da Universidade do Porto, Rua do Campo Alegre, 687, 4169-007 Porto (Portugal); Correia, J. G. [C2TN, Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Estrada Nacional 10, 2695-066 Bobadela LRS (Portugal)

    2014-12-14

    This work presents an atomic scale study of the electric field gradient (EFG) in the tetragonally distorted CdMn{sub 2}O{sub 4} spinel manganite. The EFG temperature dependence at the Cd and Mn sites was followed via perturbed angular correlation measurements with the {sup 111}In and {sup 111m}Cd probes, from 873 down to 12 K at Isolde-CERN. The results show that in the 12–600 K temperature range, a single Jahn-Teller distorted local phase exists. However above 100 K, a dynamic lattice distortion, evidenced by time dependent EFG fluctuations, sets in suggesting a structural instability. Above 600 K, a local MnO{sub 6} octahedra with relaxed Jahn-Teller distortions emerge and grow in the low temperature matrix, although no macroscopic tetragonal to cubic phase transition was observed.

  1. Acceleration of Medpor implant fibrovascularization with local vascular endothelial growth-factor injections: An experimental study

    Directory of Open Access Journals (Sweden)

    Mert Demirel

    2015-12-01

    Full Text Available Objective: Medpor is a biocompatible, high-density porous polyethylene implant that is used for multiple indications in plastic surgery. The most frequent complications associated with the Medpor implant are infection and implant exposure. The primary cause of these complications is poor fibrovascularization of the Medpor implant and poor nourishment of the overlying skin. The present experimental study aimed to determine whether vascular endothelial growth factor (VEGF could accelerate and increase Medpor implant fibrovascularization in vivo, and thereby improve local nourishment and prevent complications. Materials and Methods: The Medpor implant was inserted under the dorsal skin area in 40 Sprague-Dawley rats. 20 rats receiving local VEGF injections comprised the study group. The control group received saline injections. Fibrovascularization of the Medpor implants was compared. Results: In the rats injected with VEGF, the Medpor implant fibrovascularized faster, and there were more newly formed blood vessels, as compared with those in the control group. Conclusion: These findings have led to our use of VEGF-like agents that the accelerate angiogenesis in the Medpor implant as a means to reduce the incidence of such complications as infection and implant exposure. [Arch Clin Exp Surg 2015; 4(4.000: 196-201

  2. Sound Localization in Patients With Congenital Unilateral Conductive Hearing Loss With a Transcutaneous Bone Conduction Implant.

    Science.gov (United States)

    Vyskocil, Erich; Liepins, Rudolfs; Kaider, Alexandra; Blineder, Michaela; Hamzavi, Sasan

    2017-03-01

    There is no consensus regarding the benefit of implantable hearing aids in congenital unilateral conductive hearing loss (UCHL). This study aimed to measure sound source localization performance in patients with congenital UCHL and contralateral normal hearing who received a new bone conduction implant. Evaluation of within-subject performance differences for sound source localization in a horizontal plane. Tertiary referral center. Five patients with atresia of the external auditory canal and contralateral normal hearing implanted with transcutaneous bone conduction implant at the Medical University of Vienna were tested. Activated/deactivated implant. Sound source localization test; localization performance quantified using the root mean square (RMS) error. Sound source localization ability was highly variable among individual subjects, with RMS errors ranging from 21 to 40 degrees. Horizontal plane localization performance in aided conditions showed statistically significant improvement compared with the unaided conditions, with RMS errors ranging from 17 to 27 degrees. The mean RMS error decreased by a factor of 0.71 (p < 0.001). Analysis revealed improved sound localization performance in a horizontal plane with the activated transcutaneous bone conduction implant. Some patients with congenital UCHL might be capable of developing improved horizontal plane localization abilities with the binaural cues provided by this device.

  3. Local structure study of the orbital order/disorder transition in LaMnO3

    Science.gov (United States)

    Thygesen, Peter M. M.; Young, Callum A.; Beake, Edward O. R.; Romero, Fabio Denis; Connor, Leigh D.; Proffen, Thomas E.; Phillips, Anthony E.; Tucker, Matthew G.; Hayward, Michael A.; Keen, David A.; Goodwin, Andrew L.

    2017-05-01

    We use a combination of neutron and x-ray total scattering measurements together with pair distribution function (PDF) analysis to characterize the variation in local structure across the orbital order/disorder transition in LaMnO3. Our experimental data are inconsistent with a conventional order/disorder description of the transition, and reflect instead the existence of a discontinuous change in local structure between ordered and disordered states. Within the orbital ordered regime, the neutron and x-ray PDFs are best described by a local structure model with the same local orbital arrangements as those observed in the average (long-range) crystal structure. We show that a variety of meaningfully different local orbital arrangement models can give fits of comparable quality to the experimental PDFs collected within the disordered regime; nevertheless, our data show a subtle but consistent preference for the anisotropic Potts model proposed previously [M. R. Ahmed and G. A. Gehring, Phys. Rev. B 79, 174106 (2009), 10.1103/PhysRevB.79.174106]. The key implications of this model are electronic and magnetic isotropy together with the loss of local inversion symmetry at the Mn site. We conclude with a critical assessment of the interpretation of PDF measurements when characterizing local symmetry breaking in functional materials.

  4. From micro- to nanostructured implantable device for local anesthetic delivery

    Directory of Open Access Journals (Sweden)

    Zorzetto L

    2016-06-01

    Full Text Available Laura Zorzetto,1 Paola Brambilla,1 Elena Marcello,1 Nora Bloise,2 Manuela De Gregori,3 Lorenzo Cobianchi,4,5 Andrea Peloso,4,5 Massimo Allegri,6 Livia Visai,2,7 Paola Petrini1 1Department of Chemistry, Materials and Chemical Engineering ‘G. Natta’, Politecnico di Milano, Milan, 2Department of Molecular Medicine, Centre for Health Technologies (CHT, INSTM UdR of Pavia, University of Pavia, 3Pain Therapy Service, IRCCS Foundation Policlinico San Matteo Pavia, Pavia, 4General Surgery Department, IRCCS Foundation Policlinico San Matteo, Pavia, 5Departments of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia, 6Department of Surgical Sciences, University of Parma, Parma, 7Department of Occupational Medicine, Toxicology and Environmental Risks, S. Maugeri Foundation, IRCCS, Lab of Nanotechnology, Pavia, Italy Abstract: Local anesthetics block the transmission of painful stimuli to the brain by acting on ion channels of nociceptor fibers, and find application in the management of acute and chronic pain. Despite the key role they play in modern medicine, their cardio and neurotoxicity (together with their short half-life stress the need for developing implantable devices for tailored local drug release, with the aim of counterbalancing their side effects and prolonging their pharmacological activity. This review discusses the evolution of the physical forms of local anesthetic delivery systems during the past decades. Depending on the use of different biocompatible materials (degradable polyesters, thermosensitive hydrogels, and liposomes and hydrogels from natural polymers and manufacturing processes, these systems can be classified as films or micro- or nanostructured devices. We analyze and summarize the production techniques according to this classification, focusing on their relative advantages and disadvantages. The most relevant trend reported in this work highlights the effort of moving from microstructured

  5. Continuous recrystallization in pure Al-1.3% Mn investigated by local orientation analysis

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Local orientation analysis was used to investigate the continuous recrystallization process in a pure Al-1.3% Mn alloy with the emphasis on the influence of matrix orientations on the subgrain growth and precipitation. Results show that the differences of (mis)orientations in deformed matrices give rise to inhomogeneous subgrain growth and precipitation with respect to precipitate density and morphologies. Moreover, no apparent high angle grain boundaries were developed by accumulation of misorientations during subgrain growth.

  6. Enhanced local lattice distortions with the antiferromagnetic transition in the multiferroic LuMnO3

    Science.gov (United States)

    Louca, Despina; Proffen, Thomas; Lee, Seung-Hun; Cheong, Sang-Wook

    2009-03-01

    The ferroelectric hexagonal manganite, LuMnO3, has been investigated via neutron scattering and the pair density function analysis to determine the nature of the local atomic distortions with the antiferromagnetic transition, TN, of the Mn ions. While in previously reported neutron diffraction data, it was shown that all atomic coordinates changed based on symmetry considerations with TN, we hereby show that it is the ferroelectric motion of the Lu ions coupled with O distortions that exhibits a strong temperature dependence below TN as reflected in the Lu-O bonds. This suggests an enhancement of the net electric polarization below TN. At the same time, the motion of the apical O1 and O2 ions distorts the MnO5 bipyramids, leading to more buckling of the ab-layers. However, the Mn ions do not appear to distort significantly away from their equilibrium position. The oxygen distortions induced with the spin reorientations below TN may be the cause for the Lu ion displacements through electrostatic interactions and this in turn produces coupling to the electric dipole moments.

  7. Local fields in Co and Mn Co-doped ZnO

    Science.gov (United States)

    Sato, W.; Kano, Y.; Suzuki, T.; Nakagawa, M.; Kobayashi, Y.

    2016-12-01

    The magnetic properties of ZnO co-doped with 5 at. % Co and 5 at. % Mn(Zn0.90Co0.05Mn0.05O) synthesized by a solid-state reaction were investigated by means of 57Co emission Mössbauer spectroscopy. The majority of the probe ions (80 %) residing in defect-free substitutional Zn sites take the oxidation state of 57Fe 2+, and the others presumably form local defects taking the state of 57Fe 3+ at room temperature. Both components show doublets, and RT ferromagnetism was thus absent in the sample. For the measurement at 10 K, spectral broadening was observed, implying a possible presence of a weak magnetic component.

  8. Influence of Statins locally applied from orthopedic implants on osseous integration

    Directory of Open Access Journals (Sweden)

    Pauly Stephan

    2012-10-01

    Full Text Available Abstract Background Simvastatin increases the expression of bone morphogenetic protein 2 (BMP-2 in osteoblasts, therefore it is important to investigate the influence of statins on bone formation, fracture healing and implant integration. The aim of the present study was to investigate the effect of Simvastatin, locally applied from intramedullary coated and bioactive implants, on bone integration using biomechanical and histomorphometrical analyses. Methods Eighty rats received retrograde nailing of the femur with titanium implants: uncoated vs. polymer-only (poly(D,L-lactide vs. polymer plus drug coated (either Simvastatin low- or high dosed; “SIM low/ high”. Femurs were harvested after 56 days for radiographic and histomorphometric or biomechanical analysis (push-out. Results Radiographic analysis revealed no pathological findings for animals of the control and SIM low dose group. However, n=2/10 animals of the SIM high group showed osteolysis next to the implant without evidence of bacterial infection determined by microbiological analysis. Biomechanical results showed a significant decrease in fixation strength for SIM high coated implants vs. the control groups (uncoated and PDLLA. Histomorphometry revealed a significantly reduced total as well as direct bone/implant contact for SIM high- implants vs. controls (uncoated and PDLLA-groups. Total contact was reduced for SIM low vs. uncoated controls. Significantly reduced new bone formation was measured around SIM high coated implants vs. both control groups. Conclusions This animal study suggests impaired implant integration with local application of Simvastatin from intramedullary titanium implants after 8 weeks when compared to uncoated or carrier-only coated controls.

  9. Local structure distortion and spin Hamiltonian parameters of oxide-diluted magnetic semiconductor Mn-doped ZnO

    Institute of Scientific and Technical Information of China (English)

    Yang Zi-Yuan

    2009-01-01

    The local structure distortion, the spin Hamiltonian (SH) parameters, and the electric fine structure of the ground state for Mn2+(3d5) ion in ZnO crystals are systematically investigated, where spin-spin (SS), spin-other-orbit (SOO) and orbit-orbit (OO) magnetic interactions, besides the well-known spin-orbit (SO) coupling, are taken into account for the first time, by using the complete diagonalization method. The theoretical results of the second-order zero-field splitting (ZFS) parameter D, the fourth-order ZFS parameter (a-F), the Zeeman p-factors: g// and g⊥ and the energy differences of the ground state: δ1 and δ2 for Mn2+ in Mn2+: ZnO are in good agreement with experimental measurements when the three O2- ions below the Mn2+ ion rotate by 1.085° away from the [111]-axis. Hence, the local structure distortion effect plays an important role in explaining the spectroscopic properties of Mn2+ ions in Mn2+: ZnO crystals. It is found for Mn2+ ions in Mn2+: ZnO crystals that although the SO mechanism is the most important one, the contributions to the SH parameters, made by other four mechanisms, i.e. SS, SOO, OO, and SO~SS~SOO~OO mechanisms, are significant and should not be omitted, especially for calculating ZFS parameter D.

  10. The local structure and ferromagnetism in Fe-implanted SrTiO3 single crystals

    Science.gov (United States)

    Lobacheva, O.; Chavarha, M.; Yiu, Y. M.; Sham, T. K.; Goncharova, L. V.

    2014-07-01

    We report a connection between the local structure of low-level Fe impurities and vacancies as the cause of ferromagnetic behavior observed in strontium titanate single crystals (STO), which were implanted with Fe and Si ions at different doses then annealed in oxygen. The effects of Fe doping and post-implantation annealing of STO were studied by X-ray Absorption Near Edge Structure (XANES) spectroscopy and Superconducting Quantum Interference Device magnetometry. XANES spectra for Fe and Ti K- and L-edge reveal the changes in the local environment of Fe and Ti following the implantation and annealing steps. The annealing in oxygen atmosphere partially healed implantation damages and changed the oxidation state of the implanted iron from metallic Fe0 to Fe2+/Fe3+ oxide. The STO single crystals were weak ferromagnets prior to implantation. The maximum saturation moment was obtained after our highest implantation dose of 2 × 1016 Fe atom/cm2, which could be correlated with the metallic Fe0 phases in addition to the presence of O/Ti vacancies. After recrystallization annealing, the ferromagnetic response disappears. Iron oxide phases with Fe2+ and Fe3+ corresponding to this regime were identified and confirmed by calculations using Real Space Multiple Scattering program (FEFF9).

  11. Cochlear implant electrode localization in post-operative CT using a spherical measure

    DEFF Research Database (Denmark)

    Braithwaite, Benjamin Michael; Kjer, Hans Martin; Fagertun, Jens;

    2016-01-01

    the ordering of electrode contacts on implanted electrode arrays from post-operative CT images. Our method applies a specialized filter chain to the images based on a threshold and spherical measure, and selects contact positions at local maxima in the filtered image. Two datasets of 13 temporal bone specimens......When implanting cochlear implants the positions of electrodes have a large impact on the quality of the restored hearing. Due to metal artifacts it is difficult to estimate the precise location in post-operative scans. In this paper we present a method for automatically locating and determining...

  12. Anestesia local e sedação para cirurgia de implante coclear: uma alternativa possível Local anesthesia for cochlear implant surgery: a possible alternative

    Directory of Open Access Journals (Sweden)

    Rogério Hamerschmidt

    2010-10-01

    Full Text Available Aanestesia geral sempre foi motivo de dúvida dos pacientes que vão ser submetidos a qualquer cirurgia, especialmente o implante coclear. Como já realizamos as cirurgias otológicas com anestesia local e sedação, julgamos perfeitamente possível a realização da cirurgia do implante coclear também com esse tipo de anestesia, diminuindo os riscos, a morbidade e os custos para o hospital. OBJETIVOS: Estudo prospectivo para demonstrar a técnica anestésica e cirúrgica utilizada em três casos de adultos submetidos ao implante coclear, avaliando a segurança e a eficácia de tal técnica. MATERIAL E MÉTODOS: Foram feitas três cirurgias de implante coclear, duas com implante Cochlear e uma com Med-EL, sem intercorrências transoperatórias, durante a telemetria e no pós-operatório imediato. RESULTADOS: Os três pacientes adultos tiveram alta hospitalar aproximadamente três horas após a cirurgia, deambulando, sem eventos nauseosos, relatando um pós-operatório mais fácil do que esperavam, mesmo no momento da telemetria intraoperatória. CONCLUSÃO: Anestesia local e sedação é uma alternativa para casos selecionados de pacientes para o implante coclear, principalmente naqueles de mais idade ou que apresentem contraindicação para a anestesia geral, os riscos e a morbidade são menores.The aim of this paper is to illustrate the possibility of performing a cochlear implant surgery with local anesthesia and sedation, the anesthetic technique and the advantages of that in comparison to a general anesthesia. AIMS: prospective study demonstrating the possibility of doing cochlear implant surgery under local anesthesia and sedation. MATERIALS AND METHODS: we describe three successful cases operated under local anesthesia, including neural telemetry and the conditions the patient presented after the surgery, with a very good recovery and no complications during and after the procedure. RESULTS: these three surgeries show the possibility of

  13. 57Fe emission Mössbauer spectroscopy following dilute implantation of 57Mn into In 2O3

    Science.gov (United States)

    Mokhles Gerami, A.; Johnston, K.; Gunnlaugsson, H. P.; Nomura, K.; Mantovan, R.; Masenda, H.; Matveyev, Y. A.; Mølholt, T. E.; Ncube, M.; Shayestehaminzadeh, S.; Unzueta, I.; Gislason, H. P.; Krastev, P. B.; Langouche, G.; Naidoo, D.; Ólafsson, S.

    2016-12-01

    Emission Mössbauer spectroscopy has been utilised to characterize dilute 57Fe impurities in In 2O3 following implantation of 57Mn ( T 1/2 = 1.5 min.) at the ISOLDE facility at CERN. From stoichiometry considerations, one would expect Fe to adopt the valence state 3 + , substituting In 3+, however the spectra are dominated by spectral lines due to paramagnetic Fe2+. Using first principle calculations in the framework of density functional theory (DFT), the density of states of dilute Fe and the hyperfine parameters have been determined. The hybridization between the 3d-band of Fe and the 2p band of oxygen induces a spin-polarized hole on the O site close to the Fe site, which is found to be the cause of the Fe2+ state in In 2O3. Comparison of experimental data to calculated hyperfine parameters suggests that Fe predominantly enters the 8b site rather than the 24d site of the cation site in the Bixbyite structure of In 2O3. A gradual transition from an amorphous to a crystalline state is observed with increasing implantation/annealing temperature.

  14. Correlation between defect and magnetism of low energy Ar{sup +9} implanted and un-implanted Zn{sub 0.95}Mn{sub 0.05}O thin films suitable for electronic application

    Energy Technology Data Exchange (ETDEWEB)

    Neogi, S.K.; Midya, N. [Department of Physics, University of Calcutta, 92 APC Road, Kolkata 700009 (India); Pramanik, P. [Institute of RadioPhysics and Electronics, University of Calcutta, 92 A.P.C. Road, Kolkata 700009 (India); CRNN, University of Calcutta, JB Block, Sector III, Salt Lake, Kolkata 700098 (India); Banerjee, A. [Department of Physics, University of Calcutta, 92 APC Road, Kolkata 700009 (India); CRNN, University of Calcutta, JB Block, Sector III, Salt Lake, Kolkata 700098 (India); Bhattacharyya, A. [Institute of RadioPhysics and Electronics, University of Calcutta, 92 A.P.C. Road, Kolkata 700009 (India); Taki, G.S. [Variable Energy Cyclotron Centre, 1/AF, Salt Lake, Kolkata 700064 (India); Krishna, J.B.M. [UGC DAE CSR, Kolkata Centre, LB 8, Sector III, Salt Lake, Kolkata 700098 (India); Bandyopadhyay, S., E-mail: sbaphy@caluniv.ac.in [Department of Physics, University of Calcutta, 92 APC Road, Kolkata 700009 (India); CRNN, University of Calcutta, JB Block, Sector III, Salt Lake, Kolkata 700098 (India)

    2016-06-15

    The structural, morphological, optical and magnetic properties of Ar{sup +9} implanted 5 at% Mn doped ZnO films have been investigated to detect the correlation between ferromagnetism (FM) and defect. Sol–gel derived films were implanted with fluences 0 (un-implanted), 5×10{sup 14} (low), 10{sup 15} (intermediate) and 10{sup 16} (high) ions/cm{sup 2}. Rutherford back scattering (RBS), X-ray diffraction (XRD), atomic force microscope (AFM) and magnetic force microscope (MFM), UV–visible, photoluminescence and X-ray absorption spectroscopy (XAS) and superconducting quantum interference device vibrating sample magnetometer (SQUID VSM) were employed for investigation. XRD indicated single phase nature of the films. Absence of impurity phase has been confirmed from several other measurements also. Ion implantation induces a large concentration of point defects into the films as identified from optical study. All films exhibit intrinsic FM at room temperature (RT). The magnetization attains the maximum for the film implanted with fluence 10{sup 16} ions/cm{sup 2} with saturation magnetization (M{sub S}) value 0.69 emu/gm at RT. Magnetic properties of the films were interpreted using bound magnetic polaron (BMP). BMP generated from the intrinsic exchange interaction of Mn{sup 2+} ions and V{sub Zn} related defects actually controls the FM. The practical utility of these films in transparent spin electronic device has also been exhibited. - Highlights: • Synthesis of transparent 5 at% Mn doped ZnO films was done by sol-gel technique. • Defect induced intrinsic ferromagnetism was observed for Ar{sup 9+} ion implanted films. • The maximum magnetization was attained for highest dose of Ar{sup 9+} implantation. • Zn vacancy may favors intrinsic ferromagnetic ordering. • Intrinsic ferromagnetism was interpreted in terms of bound magnetic polaron model.

  15. Into the Paradigm of Local Factors as Contributors for Peri-implant Disease: Short Communication.

    Science.gov (United States)

    Monje, Alberto; Galindo-Moreno, Pablo; Tözüm, Tolga Fikret; Suárez-López del Amo, Fernando; Wang, Hom-Lay

    2016-01-01

    Although some systemic conditions have been associated with peri-implant disease, local contributing factors largely remain to be determined. This study aimed at evaluating, based on clinical photographs obtained from peri-implantitis treatment publications, the possible local contributing factors involved in its development based upon a survey obtained from three experienced clinicians (> 20 years of expertise). Cohen's kappa index was used to test the interexaminer reliability. "Too-buccal implant position" was the only parameter to reach almost perfect interexaminer agreement (κ = 0.81). "Thin-tissue biotype" and "minimal presence of keratinized mucosa" demonstrated moderate agreement (κ = 0.43 and κ = 0.58, respectively). The rest of the parameters studied based on clinical photographs were fair or poor. Therefore, based on this clinicians' survey, implants too buccally placed, minimal or a lack of keratinized mucosa, and thin-tissue biotype might contribute to a higher susceptibility of developing peri-implantitis. These factors must be the focus of attention in future cross-sectional studies on the incidence of peri-implant diseases.

  16. Local modification of the magnetic vortex-core velocity by gallium implantation

    Energy Technology Data Exchange (ETDEWEB)

    Langner, Hauke H., E-mail: hlangner@physnet.uni-hamburg.de; Vogel, Andreas; Beyersdorff, Björn [Institut für Angewandte Physik und Zentrum für Mikrostrukturforschung, Universität Hamburg, Jungiusstr. 11, 20355 Hamburg (Germany); Weigand, Markus [Max-Planck-Institut für Intelligente Systeme, Heisenbergstraße 3, 70596 Stuttgart (Germany); Frömter, Robert; Peter Oepen, Hans; Meier, Guido [Institut für Angewandte Physik und Zentrum für Mikrostrukturforschung, Universität Hamburg, Jungiusstr. 11, 20355 Hamburg (Germany); The Hamburg Centre for Ultrafast Imaging, Luruper Chaussee 149, 22761 Hamburg (Germany)

    2014-03-14

    The dynamics of magnetic vortices in microsquares with local modifications of magnetic parameters and thickness are investigated. By implanting gallium ions with focussed ion beam into permalloy thin-film elements, we have locally tailored their magnetic properties and the layer thickness. The vortex of the Landau domain pattern of a square is resonantly excited to a gyrotropic motion and crosses regions with and without implantation. With time-resolved scanning transmission x-ray microscopy, we observe an abrupt change in the vortex velocity close to the borders between the two regions.

  17. Adjunctive Systemic and Local Antimicrobial Therapy in the Surgical Treatment of Peri-implantitis: A Randomized Controlled Clinical Trial.

    Science.gov (United States)

    Carcuac, O; Derks, J; Charalampakis, G; Abrahamsson, I; Wennström, J; Berglundh, T

    2016-01-01

    The aim of the present randomized controlled clinical trial was to investigate the adjunctive effect of systemic antibiotics and the local use of chlorhexidine for implant surface decontamination in the surgical treatment of peri-implantitis. One hundred patients with severe peri-implantitis were recruited. Surgical therapy was performed with or without adjunctive systemic antibiotics or the local use of chlorhexidine for implant surface decontamination. Treatment outcomes were evaluated at 1 y. A binary logistic regression analysis was used to identify factors influencing the probability of treatment success, that is, probing pocket depth ≤5 mm, absence of bleeding/suppuration on probing, and no additional bone loss. Treatment success was obtained in 45% of all implants but was higher in implants with a nonmodified surface (79%) than those with a modified surface (34%). The local use of chlorhexidine had no overall effect on treatment outcomes. While adjunctive systemic antibiotics had no impact on treatment success at implants with a nonmodified surface, a positive effect on treatment success was observed at implants with a modified surface. The likelihood for treatment success using adjunctive systemic antibiotics in patients with implants with a modified surface, however, was low. As the effect of adjunctive systemic antibiotics depended on implant surface characteristics, recommendations for their use in the surgical treatment of peri-implantitis should be based on careful assessments of the targeted implant (ClinicalTrials.gov NCT01857804).

  18. Mössbauer spectra obtained using β − γ coincidence method after {sup 57}Mn implantation into LiH and LiD

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Y.; Kobayashi, Y., E-mail: kyoshio@pc.uec.ac.jp [University of Electro-Communication, Graduate School of Engineering and Science (Japan); Yamada, Y. [Tokyo University of Science, Department of Chemistry (Japan); Kubo, M. K. [International Christian University, Division of Arts Science (Japan); Mihara, M. [Osaka University, Graduate School of Science (Japan); Nagatomo, T. [RIKEN, Nishina Center Accelerator Based Science (Japan); Sato, W. [Kanazawa University, Department of Chemistry (Japan); Miyazaki, J. [Tokyo University Agri. Technology, Department of Chemistry and Engineering (Japan); Tanigawa, S.; Natori, D. [University of Electro-Communication, Graduate School of Engineering and Science (Japan); Sato, S.; Kitagawa, A. [National Institute Radiological Sciences (NIRS) (Japan)

    2016-12-15

    Highly energetic {sup 57}Mn (T{sub 1/2} = 1.45 m) was generated by nuclear projectile fragmentation in a heavy-ion accelerator, and implanted into lithium hydride (LiH) and lithium deuteride (LiD) at 578 K. Mössbauer spectroscopy with β − γ coincidence detection was then carried out on the {sup 57}Fe obtained from β{sup −}decay of the {sup 57}Mn to study the time dependence of the site distributions and coordination environments of dilute Fe atoms implanted in the LiH and LiD. The results suggest that the Fe atoms can substitute for either the Li and H or D atoms within 100 ns. Additionally, the displacement behavior of the substitutional {sup 57}Fe atoms on the lattice sites is discussed.

  19. Augmentation of localized defects of the anterior maxillary ridge with autogenous bone before insertion of implants

    NARCIS (Netherlands)

    Raghoebar, GM; Batenburg, RHK; Vissink, A; Reintsema, H

    1996-01-01

    Purpose: This study evaluated the applicability of intraorally harvested autogenous bone grafts for the augmentation of the narrow maxillary alveolar ridge to enable insertion of implants for single tooth replacement. Materials and Methods: Local defects of the anterior maxilla were reconstructed in

  20. Quantitative immunohistochemical examination of the local cellular reactions following implantation of biomaterials.

    Science.gov (United States)

    Walschus, U; Hoene, A; Kochanowski, A; Neukirch, B; Patrzyk, M; Wilhelm, L; Schröder, K; Schlosser, M

    2011-04-01

    Examining the biocompatibility of implant materials includes the in vivo investigation of the local tissue response following implantation in experimental animals. By contrast to qualitative and semi-quantitative approaches often used in this field, a quantitative technique would facilitate a more accurate determination and better comparability of different studies. Therefore, this study aimed at evaluating the applicability of the free image analysis software ImageJ for fast, easy and reproducible quantification of the tissue response following implantation of titanium samples in rats with subsequent immunohistochemical examination of peri-implant tissue samples for monocytes and macrophages (ED1) and MHC class II positive antigen presenting cells (OX6). The quantification of positively stained cells in the vicinity of the implant pockets was based on a grid-supported manual count carried out using two ImageJ plugins (CellCounter, Grid) and resulted in a mean coefficient of variation of 13.8% (ED1) and 19.6% (OX6) between different investigators and 10.0% (ED1) and 13.8% (OX6) for repeated counting by the same investigator. In conclusion, ImageJ was found to be suitable for morphometric evaluation of the tissue response following implantation, particularly the analysis of discrete cellular events at the tissue-biomaterial interface. The procedure which was used is described in detail, and its advantages and disadvantages are discussed.

  1. Development of neuromodulation and localization research on implantable device

    Directory of Open Access Journals (Sweden)

    Hong-wei HAO

    2015-09-01

    Full Text Available After over twenty years of clinical research and application, neuromodulation technology has significant efficacy and broad prospect in movement disorders, pain, epilepsy and psychiatric diseases. In this paper, localization process and future trends of typical neurostimulation systems such as deep brain stimulator and vagus nerve stimulator were introduced. DOI: 10.3969/j.issn.1672-6731.2015.09.004

  2. Suppression of martensitic transformation in Fe50Mn23Ga27 by local symmetry breaking

    Science.gov (United States)

    Ma, Tianyu; Liu, Xiaolian; Yan, Mi; Wu, Chen; Ren, Shuai; Li, Huiying; Fang, Minxia; Qiu, Zhiyong; Ren, Xiaobing

    2015-05-01

    Defects-induced local symmetry breaking has led to unusual properties in nonferromagnetic ferroelastic materials upon suppressing their martensitic transformation. Thus, it is of interest to discover additional properties by local symmetry breaking in one important class of the ferroelastic materials, i.e., the ferromagnetic shape memory alloys. In this letter, it is found that local symmetry breaking including both tetragonal nano-inclusions and anti-phase boundaries (APBs), suppresses martensitic transformation of a body-centered-cubic Fe50Mn23Ga27 alloy, however, does not affect the magnetic ordering. Large electrical resistivity is retained to the low temperature ferromagnetic state, behaving like a half-metal ferromagnet. Lower ordering degree at APBs and local stress fields generated by the lattice expansion of tetragonal nanoparticles hinder the formation of long-range-ordered martensites. The half-metal-like conducting behavior upon suppressing martensitic transformation extends the regime of ferromagnetic shape memory materials and may lead to potential applications in spintronic devices.

  3. Magnetic hybride layers. Magnetic properties of locally exchange-coupled NiFe/IrMn layers; Magnetische Hybridschichten. Magnetische Eigenschaften lokal austauschgekoppelter NiFe/IrMn-Schichten

    Energy Technology Data Exchange (ETDEWEB)

    Hamann, Christine

    2010-10-06

    By the lateral modification of the magnetic properties of exchange-coupled NiFe/IrMn layers soft-magnetic layers were produced, which show both new static and dynamic properties. As lateral structuration methods hereby the localoxidation as well as ion implantation were applied. By means of thes procedures it has been succeeded to mould specific magnetic domain configurations with strp structure into the layers. In dependence of the structure orientation as well as strip period the remagnetization behavior as well as the magnetic-resonance frequency and damping of the layers could directly be modified. The new dynamical properties are hereby discussed in the framework of the coupling via dynamical charges and the direct affection of the effective field of the artificially inserted domain state. The presented results prove by this the large potential of the lateral magneto-structuration for the tuning of specifical static as well as dynamic properties of magnetically thin layers.

  4. Local and systemic changes associated with long-term, percutaneous, static implantation with titanium alloys in rhesus macaques (Macaca mulatta)

    Energy Technology Data Exchange (ETDEWEB)

    Frydman, Galit F.; Marini, Robert P.; Bakthavatchalu, Vasudevan; Biddle, Kathleen; Muthupalani, Sureshkumar; Vanderburg, Charles R.; Lai, Barry; Bendapudi, Pavan K.; Tompkins, Ronald G.; Fox, James G.

    2017-04-01

    Metal alloys are frequently used as implant materials in veterinary medicine. Recent studies suggest that many types of metal alloys may induce both local and systemic inflammatory responses. In this study, 37 rhesus macaques with long-term skull-anchored percutaneous titanium alloy implants (0-14 years duration) were evaluated for changes in their hematology, coagulation and serum chemistry profiles. Negative controls (n=28) did not have implants. All of the implanted animals were on IACUC-approved protocols and were not implanted for the purpose of this study. Animals with implants had significantly higher plasma D-dimer and lower antithrombin III concentrations compared with nonimplanted animals (p-values < 0.05). Additionally, animals with implants had significantly higher globulin, and lower albumin and calcium concentrations compared with nonimplanted animals (p-values < 0.05). Many of these changes were positively correlated with duration of implantation as well as the number of implants. Chronic bacterial infection was observed on the skin around many of the implant sites, and within deeper tissues. Representative histopathology around the implant site of two implanted animals revealed chronic suppurative to pyogranulomatous inflammation extending from the skin to the dura mater. X-ray fluorescence microscopy of tissue biopsies from the implant site of the same two animals revealed significant increases in free metal ions within the tissue, including titanium and iron. Free metal ions persisted in the tissues up to 6 months postexplant. These results suggest that long-term skull-anchored percutaneous titanium alloy implants results in localized inflammation, chronic infection, and leaching of metal ions into local tissues.

  5. A comprehensive study of the magnetic, structural, and transport properties of the III-V ferromagnetic semiconductor InMnP

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, M.; Hübner, R.; Baehtz, C.; Skorupa, W.; Zhou, Shengqiang, E-mail: S.Zhou@hzdr.de [Helmholtz-Zentrum Dresden Rossendorf, Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, D-01328 Dresden (Germany); Gao, Kun; Helm, M. [Helmholtz-Zentrum Dresden Rossendorf, Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, D-01328 Dresden (Germany); Technische Universität Dresden, 01062 Dresden (Germany); Weschke, E. [Helmholtz-Zentrum Berlin für Materialien und Energie, Wilhelm-Conrad-Röntgen-Campus BESSY II, D-12489 Berlin (Germany); Gordan, O.; Salvan, G.; Zahn, D. R. T. [Institute of Physics, Chemnitz University of Technology, 09107 Chemnitz (Germany)

    2015-01-28

    The manganese induced magnetic, electrical, and structural modification in InMnP epilayers, prepared by Mn ion implantation and pulsed laser annealing, are investigated in the following work. All samples exhibit clear hysteresis loops and strong spin polarization at the Fermi level. The degree of magnetization, the Curie temperature, and the spin polarization depend on the Mn concentration. The bright-field transmission electron micrographs show that InP samples become almost amorphous after Mn implantation but recrystallize after pulsed laser annealing. We did not observe an insulator-metal transition in InMnP up to a Mn concentration of 5 at. %. Instead all InMnP samples show insulating characteristics up to the lowest measured temperature. Magnetoresistance results obtained at low temperatures support the hopping conduction mechanism in InMnP. We find that the Mn impurity band remains detached from the valence band in InMnP up to 5 at. % Mn doping. Our findings indicate that the local environment of Mn ions in InP is similar to GaMnAs, GaMnP, and InMnAs; however, the electrical properties of these Mn implanted III-V compounds are different. This is one of the consequences of the different Mn binding energy in these compounds.

  6. Local atomic and magnetic structure of dilute magnetic semiconductor (Ba ,K ) (Zn,Mn ) 2As2

    Science.gov (United States)

    Frandsen, Benjamin A.; Gong, Zizhou; Terban, Maxwell W.; Banerjee, Soham; Chen, Bijuan; Jin, Changqing; Feygenson, Mikhail; Uemura, Yasutomo J.; Billinge, Simon J. L.

    2016-09-01

    We have studied the atomic and magnetic structure of the dilute ferromagnetic semiconductor system (Ba ,K )(Zn ,Mn )2As2 through atomic and magnetic pair distribution function analysis of temperature-dependent x-ray and neutron total scattering data. We detected a change in curvature of the temperature-dependent unit cell volume of the average tetragonal crystallographic structure at a temperature coinciding with the onset of ferromagnetic order. We also observed the existence of a well-defined local orthorhombic structure on a short length scale of ≲5 Å , resulting in a rather asymmetrical local environment of the Mn and As ions. Finally, the magnetic PDF revealed ferromagnetic alignment of Mn spins along the crystallographic c axis, with robust nearest-neighbor ferromagnetic correlations that exist even above the ferromagnetic ordering temperature. We discuss these results in the context of other experiments and theoretical studies on this system.

  7. A Novel Enhanced Positioning Trilateration Algorithm Implemented for Medical Implant In-Body Localization

    Directory of Open Access Journals (Sweden)

    Peter Brida

    2013-01-01

    Full Text Available Medical implants based on wireless communication will play crucial role in healthcare systems. Some applications need to know the exact position of each implant. RF positioning seems to be an effective approach for implant localization. The two most common positioning data typically used for RF positioning are received signal strength and time of flight of a radio signal between transmitter and receivers (medical implant and network of reference devices with known position. This leads to positioning methods: received signal strength (RSS and time of arrival (ToA. Both methods are based on trilateration. Used positioning data are very important, but the positioning algorithm which estimates the implant position is important as well. In this paper, the proposal of novel algorithm for trilateration is presented. The proposed algorithm improves the quality of basic trilateration algorithms with the same quality of measured positioning data. It is called Enhanced Positioning Trilateration Algorithm (EPTA. The proposed algorithm can be divided into two phases. The first phase is focused on the selection of the most suitable sensors for position estimation. The goal of the second one lies in the positioning accuracy improving by adaptive algorithm. Finally, we provide performance analysis of the proposed algorithm by computer simulations.

  8. Local-spin-selective x-ray absorption and x-ray magnetic circular dichroism of MnP

    NARCIS (Netherlands)

    Groot, F.M.F. de; Pizzini, S.; Fontaine, A.; Hämäläinen, K.; Kao, C.C.; Hastings, J.B.

    1995-01-01

    The local-spin-selective X-ray absorption spectrum and the magnetic circular dichroism (MCD) spectrum are measured at the manganese K edge of MnP. A comparison of the two techniques makes it possible to determine the energy dependence of the Fano factor. It is found that the Fano factor is -4% at

  9. Clinical and Radiographic Evaluation of Immediate Loaded Dental Implants With Local Application of Melatonin: A Preliminary Randomized Controlled Clinical Trial.

    Science.gov (United States)

    El-Gammal, Mona Y; Salem, Ahmed S; Anees, Mohamed M; Tawfik, Mohamed A

    2016-04-01

    Immediate loading of dental implants in situations where low bone density exist, such as the posterior maxillary region, became possible recently after the introduction of biomimetic agents. This 1-year preliminary clinical trial was carried out to clinically and radiographically evaluate immediate-loaded 1-piece implants with local application of melatonin in the osteotomy site as a biomimetic material. 14 patients with missing maxillary premolars were randomized to receive 14 implants of 1-piece type that were subjected to immediate loading after 2 weeks of initial placement. Group I included 7 implants with acid-etched surface while group II included 7 implants with acid-etched surface combined with local application of melatonin gel at the osteotomy site. Patients were recalled for follow up at 1, 3, 6, and 12 months after loading. All implants were considered successful after 12 months of follow-up. Significant difference (P implant loading when considering the implant stability. At 1 and 3 months there were significant differences in the marginal bone level between the 2 groups. These results suggest that the local application of melatonin at the osteotomy site is associated with good stability and minimal bone resorption. However, more studies for longer follow-up periods are required to confirm the effect of melatonin hormone on osseointegration of dental implants.

  10. Theranostic 3-Dimensional nano brain-implant for prolonged and localized treatment of recurrent glioma

    Science.gov (United States)

    Ramachandran, Ranjith; Junnuthula, Vijayabhaskar Reddy; Gowd, G. Siddaramana; Ashokan, Anusha; Thomas, John; Peethambaran, Reshmi; Thomas, Anoop; Unni, Ayalur Kodakara Kochugovindan; Panikar, Dilip; Nair, Shantikumar V.; Koyakutty, Manzoor

    2017-03-01

    Localized and controlled delivery of chemotherapeutics directly in brain-tumor for prolonged periods may radically improve the prognosis of recurrent glioblastoma. Here, we report a unique method of nanofiber by fiber controlled delivery of anti-cancer drug, Temozolomide, in orthotopic brain-tumor for one month using flexible polymeric nano-implant. A library of drug loaded (20 wt%) electrospun nanofiber of PLGA-PLA-PCL blends with distinct in vivo brain-release kinetics (hours to months) were numerically selected and a single nano-implant was formed by co-electrospinning of nano-fiber such that different set of fibres releases the drug for a specific periods from days to months by fiber-by-fiber switching. Orthotopic rat glioma implanted wafers showed constant drug release (116.6 μg/day) with negligible leakage into the peripheral blood (4 month) survival of 85.7% animals whereas 07 day releasing implant showed tumor recurrence in 54.6% animals, rendering a median survival of only 74 days. In effect, we show that highly controlled drug delivery is possible for prolonged periods in orthotopic brain-tumor using combinatorial nanofibre libraries of bulk-eroding polymers, thereby controlling glioma recurrence.

  11. Lysostaphin-coated titan-implants preventing localized osteitis by Staphylococcus aureus in a mouse model.

    Directory of Open Access Journals (Sweden)

    Ceylan D Windolf

    Full Text Available The increasing incidence of implant-associated infections induced by Staphylococcus aureus (SA in combination with growing resistance to conventional antibiotics requires novel therapeutic strategies. In the current study we present the first application of the biofilm-penetrating antimicrobial peptide lysostaphin in the context of bone infections. In a standardized implant-associated bone infection model in mice beta-irradiated lysostaphin-coated titanium plates were compared with uncoated plates. Coating of the implant was established with a poly(D,L-lactide matrix (PDLLA comprising lysostaphin formulated in a stabilizing and protecting solution (SPS. All mice were osteotomized and infected with a defined count of SA. Fractures were fixed with lysostaphin-coated locking plates. Plates uncoated or PDLLA-coated served as controls. All mice underwent debridement and lavage on Days 7, 14, 28 to determine the bacterial load and local immune reaction. Fracture healing was quantified by conventional radiography. On Day 7 bacterial growth in the lavages of mice with lysostaphin-coated plates showed a significantly lower count to the control groups. Moreover, in the lysostaphin-coated plate groups complete fracture healing were observed on Day 28. The fracture consolidation was accompanied by a diminished local immune reaction. However, control groups developed an osteitis with lysis or destruction of the bone and an evident local immune response. The presented approach of terminally sterilized lysostaphin-coated implants appears to be a promising therapeutic approach for low grade infection or as prophylactic strategy in high risk fracture care e.g. after severe open fractures.

  12. Golgi localized barley MTP8 proteins facilitate Mn transport

    DEFF Research Database (Denmark)

    Pedas, Pai Rosager; Schiller, Michaela; Hegelund, Josefine Nymark;

    2014-01-01

    Many metabolic processes in plants are regulated by manganese (Mn) but limited information is available on the molecular mechanisms controlling cellular Mn homeostasis. In this study, a yeast assay was used to isolate and characterize two genes, MTP8.1 and MTP8.2 , which encode membrane-bound pro...

  13. Speech performance and sound localization abilities in Neurelec Digisonic® SP binaural cochlear implant users.

    Science.gov (United States)

    Verhaert, Nicolas; Lazard, Diane S; Gnansia, Dan; Bébéar, Jean-Pierre; Romanet, Philippe; Meyer, Bernard; Péan, Vincent; Mollard, Dominique; Truy, Eric

    2012-01-01

    In this prospective study the outcome of the Digisonic® SP Binaural cochlear implant (CI), a device enabling electric stimulation of both cochleae by a single receiver, was evaluated in 14 postlingually deafened adults after 12 months of use. Speech perception was tested using French disyllabic words in quiet and in speech-shaped noise at +10 dB signal-to-noise ratio. Horizontal sound localization in quiet was tested using pink noise coming from 5 loudspeakers, from -90 to +90° along the azimuth. Speech scores in quiet were 76% (±19.5 SD) in the bilateral condition, 62% (±24 SD) for the better ear alone and 43.5% (±27 SD) for the poorer ear alone. Speech scores in noise were 60% (±27.5 SD), 46% (±28 SD) and 28% (±25 SD), respectively, in the same conditions. Statistical analysis showed a significant advantage of the bilateral use in quiet and in noise (p Sound localization accuracy improved significantly when using the device in the bilateral condition with an average root mean square of 35°. Compared with published outcomes of usual bilateral cochlear implantation, this device could be a valuable alternative to two CIs. Prospective controlled trials, comparing the Digisonic SP Binaural CI with a standard bilateral cochlear implantation are mandatory to evaluate their respective advantages and cost-effectiveness. Copyright © 2012 S. Karger AG, Basel.

  14. Anestesia local e sedação para a cirurgia de implante coclear

    OpenAIRE

    Hamerschmidt,Rogério

    2012-01-01

    Resumo: O implante coclear é o tratamento de escolha para a surdez severa e profunda neurosensorial bilateral, porém ainda traz a morbidade associada ao fato de ser realizado com anestesia geral, sendo que esta não é possível em muitos pacientes com comorbidades associadas e de faixa etária avançada. Os obejtivos deste trabalho são de avaliar a possibilidade da realização da cirurgia de implante coclear com anestesia local e sedação e também avaliar a reação dos pacientes sob sedação no momen...

  15. Local and average structure of Mn- and La-substituted BiFeO 3

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Bo; Selbach, Sverre M.

    2017-06-01

    The local and average structure of solid solutions of the multiferroic perovskite BiFeO3 is investigated by synchrotron X-ray diffraction (XRD) and electron density functional theory (DFT) calculations. The average experimental structure is determined by Rietveld refinement and the local structure by total scattering data analyzed in real space with the pair distribution function (PDF) method. With equal concentrations of La on the Bi site or Mn on the Fe site, La causes larger structural distortions than Mn. Structural models based on DFT relaxed geometry give an improved fit to experimental PDFs compared to models constrained by the space group symmetry. Berry phase calculations predict a higher ferroelectric polarization than the experimental literature values, reflecting that structural disorder is not captured in either average structure space group models or DFT calculations with artificial long range order imposed by periodic boundary conditions. Only by including point defects in a supercell, here Bi vacancies, can DFT calculations reproduce the literature results on the structure and ferroelectric polarization of Mn-substituted BiFeO3. The combination of local and average structure sensitive experimental methods with DFT calculations is useful for illuminating the structure-property-composition relationships in complex functional oxides with local structural distortions.

  16. Sound localization in noise by normal-hearing listeners and cochlear implant users.

    Science.gov (United States)

    Kerber, Stefan; Seeber, Bernhard U

    2012-01-01

    This study aimed to characterize horizontal plane sound localization in interfering noise at different signal-to-noise ratios (SNRs) and to compare performance across normal-hearing listeners and users of unilateral and bilateral cochlear implants (CIs). CI users report difficulties with listening in noisy environments. Although their difficulties with speech understanding have been investigated in several studies, the ability to localize sounds in background noise has not extensively been examined, despite the benefits of binaural hearing being greatest in noisy situations. Sound localization is a measure of binaural processing and is thus well suited to assessing the benefit of bilateral implantation. The results will inform clinicians and implant manufacturers how to focus their efforts to improve localization with CIs in noisy situations. Six normal-hearing listeners, four unilateral, and 10 bilateral CI users indicated the perceived location of sound sources using a light pointer method. Target sounds were noise pulses played from one of 11 loudspeakers placed between -80 and +80 degrees in the frontal horizontal plane in the free field. Localization was assessed in quiet and in diffuse background noise at SNRs between +10 and -7 dB. Speech reception thresholds were measured and their relation to the localization results examined. Localization performance declined with decreasing SNR: target sounds were perceived closer to the median plane and the standard deviation of responses increased. Localization performance across groups was compared using a measure of "Spatial Resolvability" (SR). This measure gives the angular separation between two sound sources that would enable an ideal observer to correctly distinguish them 69.1% of the time. For all participants SR increased with decreasing SNR, that is, at low SNRs the spatial separation between sound sources remained distinguishable only when it was larger. Normal-hearing participants performed best, with SR

  17. Local Application of BMP-2 Specific Plasmids in Fibrin Glue does not Promote Implant Fixation

    Directory of Open Access Journals (Sweden)

    Plank Christan

    2011-07-01

    Full Text Available Abstract Background BMP-2 is known to accelerate fracture healing and might also enhance osseointegration and implant fixation. Application of recombinant BMP-2 has a time-limited effect. Therefore, a gene transfer approach with a steady production of BMP-2 appears to be attractive. The aim of this study was to examine the effect of locally applied BMP-2 plasmids on the bone-implant integration in a non-weight bearing rabbit tibia model using a comparatively new non-viral copolymer-protected gene vector (COPROG. Methods Sixty rabbits were divided into 4 groups. All of them received nailing of both tibiae. The verum group had the nails inserted with the COPROG vector and BMP-2 plasmids using fibrin glue as a carrier. Controls were a group with fibrin glue only and a blank group. After 28 and 56 days, these three groups were sacrificed and one tibia was randomly chosen for biomechanical testing, while the other tibia underwent histomorphometrical examination. In a fourth group, a reporter-gene was incorporated in the fibrin glue instead of the BMP-2 formula to prove that transfection was successful. Results Implant fixation strength was significantly lower after 28 and 56 days in the verum group. Histomorphometry supported the findings after 28 days, showing less bone-implant contact. In the fourth group, successful transfection could be confirmed by detection of the reporter-gene in 20 of 22 tibiae. But, also systemic reporter-gene expression was found in heterotopic locations, showing an undesired spreading of the locally applied gene formula. Conclusion Our results underline the transfecting capability of this vector and support the idea that BMP-2 might diminish osseointegration. Further studies are necessary to specify the exact mechanisms and the systemic effects.

  18. Comparison between bilateral cochlear implants and Neurelec Digisonic(®) SP Binaural cochlear implant: speech perception, sound localization and patient self-assessment.

    Science.gov (United States)

    Bonnard, Damien; Lautissier, Sylvie; Bosset-Audoit, Amélie; Coriat, Géraldine; Beraha, Max; Maunoury, Antoine; Martel, Jacques; Darrouzet, Vincent; Bébéar, Jean-Pierre; Dauman, René

    2013-01-01

    An alternative to bilateral cochlear implantation is offered by the Neurelec Digisonic(®) SP Binaural cochlear implant, which allows stimulation of both cochleae within a single device. The purpose of this prospective study was to compare a group of Neurelec Digisonic(®) SP Binaural implant users (denoted BINAURAL group, n = 7) with a group of bilateral adult cochlear implant users (denoted BILATERAL group, n = 6) in terms of speech perception, sound localization, and self-assessment of health status and hearing disability. Speech perception was assessed using word recognition at 60 dB SPL in quiet and in a 'cocktail party' noise delivered through five loudspeakers in the hemi-sound field facing the patient (signal-to-noise ratio = +10 dB). The sound localization task was to determine the source of a sound stimulus among five speakers positioned between -90° and +90° from midline. Change in health status was assessed using the Glasgow Benefit Inventory and hearing disability was evaluated with the Abbreviated Profile of Hearing Aid Benefit. Speech perception was not statistically different between the two groups, even though there was a trend in favor of the BINAURAL group (mean percent word recognition in the BINAURAL and BILATERAL groups: 70 vs. 56.7% in quiet, 55.7 vs. 43.3% in noise). There was also no significant difference with regard to performance in sound localization and self-assessment of health status and hearing disability. On the basis of the BINAURAL group's performance in hearing tasks involving the detection of interaural differences, implantation with the Neurelec Digisonic(®) SP Binaural implant may be considered to restore effective binaural hearing. Based on these first comparative results, this device seems to provide benefits similar to those of traditional bilateral cochlear implantation, with a new approach to stimulate both auditory nerves. Copyright © 2013 S. Karger AG, Basel.

  19. CT-guided localization of small pulmonary nodules using adjacent microcoil implantation prior to video-assisted thoracoscopic surgical resection

    Energy Technology Data Exchange (ETDEWEB)

    Su, Tian-Hao; Jin, Long; He, Wen [Capital Medical University, Department of Radiology, Beijing Friendship Hospital, Beijing (China); Fan, Yue-Feng [Xiamen University, Department of Interventional Therapy, The First Affiliated Hospital, Xiamen, Fujian (China); Hu, Li-Bao [Peking University People' s Hospital, Department of Radiology, Beijing (China)

    2015-09-15

    To describe and assess the localization of small peripheral pulmonary nodules prior to video-assisted thoracoscopic surgical (VATS) resection using the implantation of microcoils. Ninety-two patients with 101 pulmonary nodules underwent computed tomography (CT)-guided implantation of microcoils proximal to each nodule. Patients were randomly assigned to undergo entire microcoil or leaving-microcoil-end implantations. The complications and efficacy of the two implantation methods were evaluated. VATS resection of lung tissue containing each pulmonary lesion and microcoil were performed in the direction of the microcoil marker. Histopathological analysis was performed for the resected pulmonary lesions. CT-guided microcoil implantation was successful in 99/101 cases, and the placement of microcoils within 1 cm of the nodules was not disruptive. There was no difference in the complications and efficacy associated with the entire implantation method (performed for 51/99 nodules) versus the leaving-microcoil-end implantation method (performed for 48/99 nodules). All nodules were successfully removed using VATS resection. Asymptomatic pneumothorax occurred in 16 patients and mild pulmonary haemorrhage occurred in nine patients. However, none of these patients required further surgical treatment. Preoperative localization of small pulmonary nodules using a refined percutaneous microcoil implantation method was found to be safe and useful prior to VATS resection. (orig.)

  20. Prodigiosin release from an implantable biomedical device: kinetics of localized cancer drug release

    Energy Technology Data Exchange (ETDEWEB)

    Danyuo, Y.; Obayemi, J.D.; Dozie-Nwachukwu, S. [Department of Materials Science and Engineering, African University of Science and Technology (AUST), Abuja, Federal Capital Territory (Nigeria); Ani, C.J. [Department of Theoretical Physics, African University of Science and Technology (AUST), Abuja, Federal Capital Territory (Nigeria); Odusanya, O.S. [Biotechnology and Genetic Engineering Advanced Laboratory, Sheda Science and Technology Complex (SHESTCO), Abuja, Federal Capital Territory (Nigeria); Oni, Y. [Department of Chemistry, Bronx Community College, New York, NY (United States); Anuku, N. [Department of Chemistry, Bronx Community College, New York, NY (United States); Princeton Institute for the Science and Technology of Materials (PRISM), 70 Prospect Street, Princeton, NJ 08544 (United States); Malatesta, K. [Department of Chemistry, Bronx Community College, New York, NY (United States); Soboyejo, W.O., E-mail: soboyejo@princeton.edu [Department of Materials Science and Engineering, African University of Science and Technology (AUST), Abuja, Federal Capital Territory (Nigeria); Princeton Institute for the Science and Technology of Materials (PRISM), 70 Prospect Street, Princeton, NJ 08544 (United States); Department of Mechanical and Aerospace Engineering 1 Olden Street, Princeton, NJ 08544 (United States)

    2014-09-01

    This paper presents an implantable encapsulated structure that can deliver localized heating (hyperthermia) and controlled concentrations of prodigiosin (a cancer drug) synthesized by bacteria (Serratia marcesce (subsp. marcescens)). Prototypical Poly-di-methyl-siloxane (PDMS) packages, containing well-controlled micro-channels and drug storage compartments, were fabricated along with a drug-storing polymer produced by free radical polymerization of Poly(N-isopropylacrylamide)(PNIPA) co-monomers of Acrylamide (AM) and Butyl-methacrylate (BMA). The mechanisms of drug diffusion of PNIPA-base gels were elucidated. Scanning Electron Microscopy (SEM) was also used to study the heterogeneous porous structure of the PNIPA-based gels. The release exponents, n, of the gels were found to between 0.5 and 0.7. This is in the range expected for Fickian (n = 0.5). Deviation from Fickian diffusion was also observed (n > 0.5) diffusion. The gel diffusion coefficients were shown to vary between 2.1 × 10{sup −12} m{sup 2}/s and 4.8 × 10{sup −6} m{sup 2}/s. The implications of the results are then discussed for the localized treatment of cancer via hyperthermia and the controlled delivery of prodigiosin from encapsulated PNIPA-based devices. - Highlights: • Fabricated thermo-sensitive hydrogels for localized drug release from an implantable biomedical device. • Determined the cancer drug diffusion mechanisms of PNIPA-co-AM copolymer hydrogel. • Encapsulated PNIPA-based hydrogels in PDMS capsules for controlled drug delivery. • Established the kinetics of drug release from gels and channels in an implantable biomedical device. • Demonstrated the potential for the controlled release of prodigiosin (PG) as an anticancer drug.

  1. Delocalized and localized donating-accepting Mn-C interactions in half-sandwich cyclopentadienyl and pentadienyl complexes.

    Science.gov (United States)

    Solís-Huitrón, Josué; Zúñiga-Villarreal, Noé; Martínez-Otero, Diego; Barquera-Lozada, José Enrique

    2017-05-30

    The widely used cyclopentadienyl (Cp) ligand and the pentadienyl (Pdl) ligand have very similar molecular orbitals (MOs) but they have significantly different chemical behavior. The extensively mixing of the MOs in the Pdl ligand has prevented a quantitative explanation of the observed differences between these two ligands. In a series of synthesized close/open half sandwich manganese phosphine carbonyls, the quantum theory of atoms in molecules and the interacting quantum atom model allow us to quantify the accepting-donating capacities of both ligands and to break down the M-dienyl bond into individual atomic interactions. The Mn-Pdl bond is stronger, more localized and has a larger backbonding contribution than the Mn-Cp bond. All carbon atoms in the Cp ring interact similarly with the Mn center, whereas the Pdl's terminal carbon atoms exhibit a strong donor and a moderate acceptor character, and C2 and C4 have an acceptor character and C3 a donor character. Contrarily to the constrained five-membered Cp ring, the stronger Mn-Pdl interaction can barely compensate for the large destabilizing distortion of the backbone of the nonaromatic Pdl ligand.

  2. Can titanium mesh influence local recurrence management after implant-based breast reconstruction?

    Science.gov (United States)

    Riggio, Egidio; Chifu, Camelia; Martelli, Gabriele; Ferraris, Cristina

    2015-01-01

    TiLOOP(®) Bra is a permanent titanium-coated polypropylene mesh currently used in post-mastectomy breast reconstruction with implants. This mesh is generally presented as inducing low-grade inflammatory reactions, but only few reports focused on its possible side effects. In the case described here, the use of the mesh led to minor clinical problems that needed to be clinically and surgically managed at the same time as a local relapse. A patient with high-grade ductal carcinoma in situ underwent primary surgery (nipple-sparing mastectomy and one-stage reconstruction using the TiLOOP(®) Bra mesh) and was subsequently referred for radiological and clinical investigation when various nodules became apparent during a follow-up physical examination. Prior to the histopathological proof, the diagnosis of local recurrence was complicated by the occurrence of an extensive granulomatous reaction in the fixation areas along with mild inflammatory changes scattered on the surface of the mesh. This case illustrates a side effect of titanium-coated permanent mesh in immediate implant-based reconstruction, i.e. the formation of granulomas in the inframammary fold, probably in the area where the mesh had been folded or fixed. We propose a safer technical approach to avoid the problem and a clinical management strategy for patients at high risk of local recurrence who develop granuloma-like nodules. A surgical technique is suggested to prevent granuloma formation. If, however, subcutaneous nodules that may be local recurrences do appear, they should not be interpreted by default as a granulomatous reaction, but should be fully investigated and possibly excised.

  3. 5 7 Fe Emission Mössbauer Study on Gd 3 Ga 5 O 1 2 implanted with dilute 5 7 Mn

    Science.gov (United States)

    Krastev, P. B.; Gunnlaugsson, H. P.; Nomura, K.; Adoons, V.; Gerami, A. M.; Johnston, K.; Ncube, M.; Mantovan, R.; Masenda, H.; Matveyev, Y. A.; Mølholt, T. E.; Unzueta, I.; Bharuth-Ram, K.; Gislason, H.; Langouche, G.; Naidoo, D.; Ólafsson, S.

    2016-12-01

    57Fe emission Mössbauer spectroscopy has been applied to study the lattice location and properties of Fe in gadolinium gallium garnet Gd3Ga5 O 12 (GGG) single crystals in the temperature interval 300 - 563 K within the extremely dilute (CERN. These results are compared with earlier Mössbauer spectroscopy study of Fe-doped gadolinium gallium garnet Gd3Ga5 O 12(GGG), with implantation fluences between 8×1015 and 6×1016 atoms cm-2. Three Fe components are observed in the emission Mössbauer spectra: (i) high spin Fe2+ located at damage sites due to the implantation process, (ii) high spin Fe3+ at substitutional tetrahedral Ga sites, and (iii) interstitial Fe, probably due to the recoil imparted on the daughter57∗Fe nucleus in the β - decay of57Mn. In contrast to high fluence57Fe implantation studies the Fe3+ ions are found to prefer the tetrahedral Ga site over the octahedral Ga site. No annealing stages are evident in the temperature range investigated. Despite the very low concentration, high-spin Fe3+ shows fast spin relaxation, presumably due to an indirect interaction between nearby gadolinium atoms.

  4. In vivo evaluation of copper release and acute local tissue reactions after implantation of copper-coated titanium implants in rats.

    Science.gov (United States)

    Hoene, Andreas; Prinz, Cornelia; Walschus, Uwe; Lucke, Silke; Patrzyk, Maciej; Wilhelm, Lutz; Neumann, Hans-Georg; Schlosser, Michael

    2013-06-01

    Copper (Cu) based coatings can reduce infections for titanium (Ti) implants. However, Cu is also cytotoxic. To examine the balance of antibacterial versus adverse tissue effects, this study aimed at evaluating a Cu coating regarding in vivo Cu release and local inflammatory reactions for 72 h. TiAl6V4 plates received either plasma electrolytic oxidation only (Ti), or an additional galvanic Cu deposition (Ti-Cu). No Staphylococcus aureus were found in vitro on Ti-Cu after 24 h. Following simultaneous intramuscular implantation of two Ti and two Ti-Cu plates into nine rats, serum Cu was elevated until 48 h and residual Cu on explanted samples reduced accordingly after 48 h. Total and tissue macrophages around implants increased until 72 h for both series, and were increased for Ti-Cu. As numbers of total and tissue macrophages were comparable, macrophages were probably tissue-derived. MHC-class-II-positive cells increased for Ti-Cu only. T-lymphocytes had considerably lower numbers than macrophages, did not increase or differ between both series, and thus had minor importance. Tissue reactions increased beyond Cu release, indicating effects of either surface-bound Cu or more likely the implants themselves. Altogether, Ti-Cu samples possessed antibacterial effectiveness in vitro, released measurable Cu amounts in vivo and caused a moderately increased local inflammatory response, demonstrating anti-infective potential of Cu coatings.

  5. Wireless implantable chip with integrated nitinol-based pump for radio-controlled local drug delivery.

    Science.gov (United States)

    Fong, Jeffrey; Xiao, Zhiming; Takahata, Kenichi

    2015-02-21

    We demonstrate an active, implantable drug delivery device embedded with a microfluidic pump that is driven by a radio-controlled actuator for temporal drug delivery. The polyimide-packaged 10 × 10 × 2 mm(3) chip contains a micromachined pump chamber and check valves of Parylene C to force the release of the drug from a 76 μL reservoir by wirelessly activating the actuator using external radio-frequency (RF) electromagnetic fields. The rectangular-shaped spiral-coil actuator based on nitinol, a biocompatible shape-memory alloy, is developed to perform cantilever-like actuation for pumping operation. The nitinol-coil actuator itself forms a passive 185 MHz resonant circuit that serves as a self-heat source activated via RF power transfer to enable frequency-selective actuation and pumping. Experimental wireless operation of fabricated prototypes shows successful release of test agents from the devices placed in liquid and excited by radiating tuned RF fields with an output power of 1.1 W. These tests reveal a single release volume of 219 nL, suggesting a device's capacity of ~350 individual ejections of drug from its reservoir. The thermal behavior of the activated device is also reported in detail. This proof-of-concept prototype validates the effectiveness of wireless RF pumping for fully controlled, long-lasting drug delivery, a key step towards enabling patient-tailored, targeted local drug delivery through highly miniaturized implants.

  6. Acute urinary morbidity after a permanent 125I implantation for localized prostate cancer.

    Science.gov (United States)

    Ohga, Saiji; Nakamura, Katsumasa; Shioyama, Yoshiyuki; Tatsugami, Katsunori; Sasaki, Tomonari; Nonoshita, Takeshi; Yoshitake, Tadamasa; Asai, Kaori; Hirata, Hideki; Naito, Seiji; Honda, Hiroshi

    2014-11-01

    We evaluated the predictive factors of acute urinary morbidity (AUM) after prostate brachytherapy. From November 2005 to January 2007, 62 patients with localized prostate cancer were treated using brachytherapy. The (125)Iodine ((125)I) seed-delivering method was a modified peripheral pattern. The prescribed dose was 144 Gy. Urinary morbidity was scored at 3 months after implantation. The clinical and treatment parameters were analysed for correlation with AUM. In particular, in this study, Du90 (the minimal dose received by 90% of the urethra), Dup90 (the minimal dose received by 90% of the proximal half of the urethra on the bladder side) and Dud90 (the minimal dose received by 90% of the distal half of the urethra on the penile side) were analysed. We found that 43 patients (69.4%) experienced acute urinary symptoms at 3 months after implantation. Of them, 40 patients had Grade 1 AUM, one patient had Grade 2 pain, and two patients had Grade 2 urinary frequency. None of the patients had ≥Grade 3. Univariate and multivariate analysis revealed that Du90 and Dup90 were significantly correlated with AUM. In this study, Du90 and Dup90 were the most significant predictors of AUM after prostate brachytherapy.

  7. Prediction of STN-DBS Electrode Implantation Track in Parkinson's Disease by Using Local Field Potentials

    Science.gov (United States)

    Telkes, Ilknur; Jimenez-Shahed, Joohi; Viswanathan, Ashwin; Abosch, Aviva; Ince, Nuri F.

    2016-01-01

    Optimal electrophysiological placement of the DBS electrode may lead to better long term clinical outcomes. Inter-subject anatomical variability and limitations in stereotaxic neuroimaging increase the complexity of physiological mapping performed in the operating room. Microelectrode single unit neuronal recording remains the most common intraoperative mapping technique, but requires significant expertise and is fraught by potential technical difficulties including robust measurement of the signal. In contrast, local field potentials (LFPs), owing to their oscillatory and robust nature and being more correlated with the disease symptoms, can overcome these technical issues. Therefore, we hypothesized that multiple spectral features extracted from microelectrode-recorded LFPs could be used to automate the identification of the optimal track and the STN localization. In this regard, we recorded LFPs from microelectrodes in three tracks from 22 patients during DBS electrode implantation surgery at different depths and aimed to predict the track selected by the neurosurgeon based on the interpretation of single unit recordings. A least mean square (LMS) algorithm was used to de-correlate LFPs in each track, in order to remove common activity between channels and increase their spatial specificity. Subband power in the beta band (11–32 Hz) and high frequency range (200–450 Hz) were extracted from the de-correlated LFP data and used as features. A linear discriminant analysis (LDA) method was applied both for the localization of the dorsal border of STN and the prediction of the optimal track. By fusing the information from these low and high frequency bands, the dorsal border of STN was localized with a root mean square (RMS) error of 1.22 mm. The prediction accuracy for the optimal track was 80%. Individual beta band (11–32 Hz) and the range of high frequency oscillations (200–450 Hz) provided prediction accuracies of 72 and 68% respectively. The best

  8. Locally advanced breast implant associated anaplastic large cell lymphoma: A case report of successful treatment with radiation and chemotherapy

    Directory of Open Access Journals (Sweden)

    Christopher Fleighton Estes

    2015-02-01

    Full Text Available The development of breast implant associated anaplastic large cell lymphoma (ALCL is a rare phenomenon. A typical presentation is an effusion associated with a breast implant. Less commonly, disease can become more advanced locoregionally or distantly. The optimal treatment schema is a topic of debate: localized ALCL can potentially be cured with implant removal alone, while other cases in the literature, including those that are more advanced, have been treated with varying combinations of surgery, chemotherapy, and external beam radiotherapy. This is a case report of breast implant ALCL with pathologically proven lymph node involvement, the fifth such patient reported. Our patient experienced a favorable outcome with radiation therapy and chemotherapy.

  9. Development of Sound Localization Strategies in Children with Bilateral Cochlear Implants.

    Directory of Open Access Journals (Sweden)

    Yi Zheng

    Full Text Available Localizing sounds in our environment is one of the fundamental perceptual abilities that enable humans to communicate, and to remain safe. Because the acoustic cues necessary for computing source locations consist of differences between the two ears in signal intensity and arrival time, sound localization is fairly poor when a single ear is available. In adults who become deaf and are fitted with cochlear implants (CIs sound localization is known to improve when bilateral CIs (BiCIs are used compared to when a single CI is used. The aim of the present study was to investigate the emergence of spatial hearing sensitivity in children who use BiCIs, with a particular focus on the development of behavioral localization patterns when stimuli are presented in free-field horizontal acoustic space. A new analysis was implemented to quantify patterns observed in children for mapping acoustic space to a spatially relevant perceptual representation. Children with normal hearing were found to distribute their responses in a manner that demonstrated high spatial sensitivity. In contrast, children with BiCIs tended to classify sound source locations to the left and right; with increased bilateral hearing experience, they developed a perceptual map of space that was better aligned with the acoustic space. The results indicate experience-dependent refinement of spatial hearing skills in children with CIs. Localization strategies appear to undergo transitions from sound source categorization strategies to more fine-grained location identification strategies. This may provide evidence for neural plasticity, with implications for training of spatial hearing ability in CI users.

  10. Secondary external-beam radiotherapy and hyperthermia for local recurrence after 125-iodine implantation in adenocarcinoma of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, I.; Kapp, D.S.; Bagshaw, M.A. (Stanford Univ. School of Medicine, CA (USA))

    1991-03-01

    At Standford, six patients underwent a course of external radiotherapy after local recurrence following 125-iodine implantation. Four of the six patients also received concomitant hyperthermia. Four patients were initially managed with hormonal manipulation at time of local relapse and subsequently received external beam radiotherapy with or without hyperthermia. The hyperthermia was non-invasively induced using an annular phased array radiative electromagnetic system. Treatment was well tolerated, and none of the patients experienced severe rectal or bladder complications. Three patients are free from disease; one patient experience local-regional recurrence based on biopsy; one recurred in the bladder, was treated with cystoprostatectomy and subsequently succumbed to metastatic disease; and one patient died of presumed metastatic disease. External-beam irradiation with concurrent hyperthermia can be safely delivered to treat locally recurrent prostatic carcinoma after 125-iodine implantation.

  11. Development of a novel method for surgical implant design optimization through noninvasive assessment of local bone properties.

    Science.gov (United States)

    Schiuma, D; Brianza, S; Tami, A E

    2011-03-01

    A method was developed to improve the design of locking implants by finding the optimal paths for the anchoring elements, based on a high resolution pQCT assessment of local bone mineral density (BMD) distribution and bone micro-architecture (BMA). The method consists of three steps: (1) partial fixation of the implant to the bone and creation of a reference system, (2) implant removal and pQCT scan of the bone, and (3) determination of BMD and BMA of all implant-anchoring locations along the actual and alternative directions. Using a PHILOS plate, the method uncertainty was tested on an artificial humerus bone model. A cadaveric humerus was used to quantify how the uncertainty of the method affects the assessment of bone parameters. BMD and BMA were determined along four possible alternative screw paths as possible criteria for implant optimization. The method is biased by a 0.87 ± 0.12 mm systematic uncertainty and by a 0.44 ± 0.09 mm random uncertainty in locating the virtual screw position. This study shows that this method can be used to find alternative directions for the anchoring elements, which may possess better bone properties. This modification will thus produce an optimized implant design.

  12. Accurate localization of in-body medical implants based on spatial sparsity.

    Science.gov (United States)

    Pourhomayoun, Mohammad; Jin, Zhanpeng; Fowler, Mark L

    2014-02-01

    Wearable and implantable wireless communication devices have in recent years gained increasing attention for medical diagnostics and therapeutics. In particular, wireless capsule endoscopy has become a popular method to visualize and diagnose the human gastrointestinal tract. Estimating the exact position of the capsule when each image is taken is a very critical issue in capsule endoscopy. Several approaches have been developed by researchers to estimate the capsule location. However, some unique challenges exist for in-body localization, such as the severe multipath issue caused by the boundaries of different organs, inconsistency of signal propagation velocity and path loss parameters inside the human body, and the regulatory restrictions on using high-bandwidth or high-power signals. In this paper, we propose a novel localization method based on spatial sparsity. We directly estimate the location of the capsule without going through the usual intermediate stage of first estimating time-of-arrival or received-signal strength, and then a second stage of estimating the location. We demonstrate the accuracy of the proposed method through extensive Monte Carlo simulations for radio frequency emission signals within the required power and bandwidth range. The results show that the proposed method is effective and accurate, even in massive multipath conditions.

  13. Miniaturized implantable sensors for in vivo localized temperature measurements in mice during cold exposure.

    Science.gov (United States)

    Padovani, R; Lehnert, T; Cettour-Rose, P; Doenlen, R; Auwerx, J; Gijs, M A M

    2016-02-01

    We report on in vivo temperature measurements performed in mice at two specific sites of interest in the animal body over a period of several hours. In particular, the aim of this work was to monitor mouse metabolism during cold exposure, and to record possible temperature differences between the body temperature measured in the abdomen and the temperature of the brown adipose tissue (BAT) situated in the interscapular area. This approach is of biological interest as it may help unravelling the question whether biochemical activation of BAT is associated with local increase in metabolic heat production. For that purpose, miniaturized thermistor sensors have been accurately calibrated and implanted in the BAT and in the abdominal tissue of mice. After 1 week of recovery from surgery, mice were exposed to cold (6 °C) for a maximum duration of 6 h and the temperature was acquired continuously from the two sensors. Control measurements with a conventional rectal probe confirmed good performance of both sensors. Moreover, two different mouse phenotypes could be identified, distinguishable in terms of their metabolic resistance to cold exposure. This difference was analyzed from the thermal point of view by computational simulations. Our simple physical model of the mouse body allowed to reproduce the global evolution of hypothermia and also to explain qualitatively the temperature difference between abdomen and BAT locations. While with our approach, we have demonstrated the importance and feasibility of localized temperature measurements on mice, further optimization of this technique may help better identify local metabolism variations.

  14. Sound Source Localization and Speech Understanding in Complex Listening Environments by Single-sided Deaf Listeners After Cochlear Implantation.

    Science.gov (United States)

    Zeitler, Daniel M; Dorman, Michael F; Natale, Sarah J; Loiselle, Louise; Yost, William A; Gifford, Rene H

    2015-09-01

    To assess improvements in sound source localization and speech understanding in complex listening environments after unilateral cochlear implantation for single-sided deafness (SSD). Nonrandomized, open, prospective case series. Tertiary referral center. Nine subjects with a unilateral cochlear implant (CI) for SSD (SSD-CI) were tested. Reference groups for the task of sound source localization included young (n = 45) and older (n = 12) normal-hearing (NH) subjects and 27 bilateral CI (BCI) subjects. Unilateral cochlear implantation. Sound source localization was tested with 13 loudspeakers in a 180 arc in front of the subject. Speech understanding was tested with the subject seated in an 8-loudspeaker sound system arrayed in a 360-degree pattern. Directionally appropriate noise, originally recorded in a restaurant, was played from each loudspeaker. Speech understanding in noise was tested using the Azbio sentence test and sound source localization quantified using root mean square error. All CI subjects showed poorer-than-normal sound source localization. SSD-CI subjects showed a bimodal distribution of scores: six subjects had scores near the mean of those obtained by BCI subjects, whereas three had scores just outside the 95th percentile of NH listeners. Speech understanding improved significantly in the restaurant environment when the signal was presented to the side of the CI. Cochlear implantation for SSD can offer improved speech understanding in complex listening environments and improved sound source localization in both children and adults. On tasks of sound source localization, SSD-CI patients typically perform as well as BCI patients and, in some cases, achieve scores at the upper boundary of normal performance.

  15. Permanent and transient effects of locally delivered n-acetyl cysteine in a guinea pig model of cochlear implantation.

    Science.gov (United States)

    Eastwood, Hayden; Pinder, Darren; James, David; Chang, Andrew; Galloway, Stuart; Richardson, Rachael; O'Leary, Stephen

    2010-01-01

    Protection of residual hearing after cochlear implant surgery can improve the speech and music perception of cochlear implant recipients, particularly in the presence of background noise. Surgical trauma and chronic inflammation are thought to be responsible for a significant proportion of residual hearing loss after surgery. Local delivery of the anti-oxidant precursor n-acetyl cysteine (NAC) to the cochlea via round window 30min prior to surgery, increased the level of residual hearing at 24-32kHz 4weeks post surgery compared to controls. The hearing protection was found in the basal turn near the site of implantation. Coincidentally, the basal turn was also the location that sustained the greatest hearing loss. As well as protecting residual hearing, NAC-treated animals demonstrated a reduction in the chronic inflammatory changes associated with implantation. While these findings indicate that anti-oxidant therapy can be used to reduce the hearing loss associated with surgical trauma, the local delivery of NAC was associated with a transient increase in hearing thresholds, and osseoneogenesis was seen in a greater number of NAC-treated animals. These side-effects would limit its clinical use through local cochlear administration. However, it is not known yet whether these effects would also be produced by other anti-oxidants, or ameliorated by using a different route of administration.

  16. Local anesthesia for cochlear implant surgery: low risks for the patient and few costs for the hospital, a rational alternative.

    Science.gov (United States)

    Hamerschmidt, R; Mocellin, M; Gasperin, A; Faria, J L G; Wiemes, G; Kutianski, V; Pasinato, L; Soares, W

    2011-01-01

    The aim of this article is to illustrate the possibility of performing a cochlear implant with local anesthesia and sedation, the anesthesic technique and the advantages of that in comparison to a general anesthesia. We describe two successful surgeries done with local anesthesia, including the neural telemetry and the conditions the patient presented after the surgery, with a very good recovery and no complications during and after the procedure. The results of these two surgeries are described regarding the fast recovery, no symptoms of dizziness and vomiting after the surgeries, discharging from the hospital on the same day, and the immediate post operative period by meaning of complaints from the patient. Local anesthesia with sedation for cochlear implant surgery in adults is a very good alternative for lowering the morbidity of the patient, fewer risks, lower costs for the hospital, with a very good control of the surgery.

  17. Changes in local surface structure and Sr depletion in Fe-implanted SrTiO3 (001)

    Science.gov (United States)

    Lobacheva, O.; Yiu, Y. M.; Chen, N.; Sham, T. K.; Goncharova, L. V.

    2017-01-01

    Local surface structure of single crystal strontium titanate SrTiO3 (001) samples implanted with Fe in the range of concentrations between 2 × 1014 to 2 × 1016 Fe/cm2 at 30 keV has been investigated. In order to facilitate Fe substitution (doping), implanted samples were annealed in oxygen at 350 °C. Sr depletion was observed from the near-surface layers impacted by the ion-implantation process, as revealed by Rutherford Backscattering Spectrometry (RBS), X-ray photoelectron spectroscopy (XPS), X-ray Absorption Near Edge Spectroscopy (XANES), and Atomic Force Microscopy (AFM). Hydrocarbon contaminations on the surface may contribute to the mechanisms of Sr depletion, which have important implications for Sr(Ti1-xFex)O3-δ materials in gas sensing applications.

  18. Atomic distribution, local structure and cation size effect in o-R1-xCaxMnO3 (R = Dy, Y, and Ho).

    Science.gov (United States)

    Jiang, Ning; Zhang, X; Yu, Yi

    2013-11-27

    We propose new interatomic potentials for the small rare-earth-based orthorhombic RMnO3 (R = Dy, Y, Ho), which accurately model the structural properties of these extreme cases of lanthanide manganate series. They are further employed to investigate the intrinsic defects in o-RMnO3 and the cation distribution and local structure in o-R1-xCaxMnO3 (R = Dy, Y, Ho). Schottky disorders are found to be the dominant structural defects, and the possibility of a small degree of anti-site disorder of R and Mn ions over A and B sites is found. The introduced Ca dopants tend to form chemically and structurally like CaMnO3 clusters in the lightly doped system, which can be regarded as representations of microscopic phase separation. The local structural disorder is reduced with increasing doping density. For o-R0.5Ca0.5MnO3 (R = Dy, Y, Ho), the charge ordering state is intrinsically favored, and the layer stripe model is shown to be energetically more favorable and structurally more reasonable. Moreover, the tendency to form charge ordered stripes increases with the decrease of R size. The local structure in the layer stripe pattern deviates largely from the average structure: RMnO3-like and CaMnO3-like layers are formed. The size of R ion has a significant influence on the doping effect on Jahn-Teller (JT) distortion and a manganate with a larger R will experience a larger reduction on the anisotropy of Mn-O bonds in Mn(3+)O6 octahedra. However, the change of octahedral tilting upon doping does not vary much with R radii.

  19. A comparative study of seed localization and dose calculation on pre- and post-implantation ultrasound and CT images for low-dose-rate prostate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Imad; Algan, Ozer; Thompson, Spencer; Sindhwani, Puneet; Herman, Terence; Cheng, C.-Y.; Ahmad, Salahuddin [Department of Radiation Oncology, University of Oklahoma Health Sciences Center, 825 NE 10th Street, OUPB 1430, Oklahoma City, OK 73104 (United States)], E-mail: iali@ouhsc.edu

    2009-09-21

    This work investigates variation in the volume of the prostate measured at different stages through the prostate brachytherapy procedure for 30 patients treated with I-125 radioactive seeds. The implanted seeds were localized on post-implantation ultrasound (US) images and the effect of prostate enlargement due to edema on dose coverage for 15 patients was studied. The volume of the prostate was measured at four stages as follows: (a) 2-3 weeks prior to implantation using US imaging, (b) then at the start of the intra-operative prostate brachytherapy procedure on the day of the implant, (c) immediately post-implantation using US imaging in the operating room and (d) finally by CT imaging at nearly 4 weeks post-implantation. Comparative prostate volume studies were performed using US imaging stepper and twister modes. For the purpose of this study, the implanted seeds were localized successfully on post-implant ultrasound twister images, retrospectively. The plans using post-implant US imaging were compared with intra-operative plans on US and plans created on CT images. The prostate volume increases about 10 cm{sup 3} on average due to edema induced by needle insertion and seed loading during implantation. The visibility of the implanted seeds on US twister images acquired post-implantation is as good as those on CT images and can be localized and used for dose calculation. The dose coverage represented by parameters such as D90 (dose covering 90% of the volume) and V100 (volume covered by 100% dose) is poorer on plans performed on post-implantation twister US studies than on the intra-operative live plan or the CT scan performed 4 weeks post-operatively. For example, the mean D90 difference on post-implantation US is lower by more than 15% than that on pre-implantation US. The volume enlargement of the prostate due to edema induced by needle insertion and seed placement has a significant effect on the quality of dosimetric coverage in brachytherapy prostate seed

  20. A comparative study of seed localization and dose calculation on pre- and post-implantation ultrasound and CT images for low-dose-rate prostate brachytherapy

    Science.gov (United States)

    Ali, Imad; Algan, Ozer; Thompson, Spencer; Sindhwani, Puneet; Herman, Terence; Cheng, Chih-Yao; Ahmad, Salahuddin

    2009-09-01

    This work investigates variation in the volume of the prostate measured at different stages through the prostate brachytherapy procedure for 30 patients treated with I-125 radioactive seeds. The implanted seeds were localized on post-implantation ultrasound (US) images and the effect of prostate enlargement due to edema on dose coverage for 15 patients was studied. The volume of the prostate was measured at four stages as follows: (a) 2-3 weeks prior to implantation using US imaging, (b) then at the start of the intra-operative prostate brachytherapy procedure on the day of the implant, (c) immediately post-implantation using US imaging in the operating room and (d) finally by CT imaging at nearly 4 weeks post-implantation. Comparative prostate volume studies were performed using US imaging stepper and twister modes. For the purpose of this study, the implanted seeds were localized successfully on post-implant ultrasound twister images, retrospectively. The plans using post-implant US imaging were compared with intra-operative plans on US and plans created on CT images. The prostate volume increases about 10 cm3 on average due to edema induced by needle insertion and seed loading during implantation. The visibility of the implanted seeds on US twister images acquired post-implantation is as good as those on CT images and can be localized and used for dose calculation. The dose coverage represented by parameters such as D90 (dose covering 90% of the volume) and V100 (volume covered by 100% dose) is poorer on plans performed on post-implantation twister US studies than on the intra-operative live plan or the CT scan performed 4 weeks post-operatively. For example, the mean D90 difference on post-implantation US is lower by more than 15% than that on pre-implantation US. The volume enlargement of the prostate due to edema induced by needle insertion and seed placement has a significant effect on the quality of dosimetric coverage in brachytherapy prostate seed

  1. Microstructural observation of helium implanted and creep ruptured Fe 25%Ni 15%Cr alloys containing various MC and MN formers

    Science.gov (United States)

    Yamamoto, Norikazu; Nagakawa, Johsei; Murase, Yoshiharu; Shiraishi, Haruki

    1998-10-01

    Transmission electron microscopic observations have been carried out on Fe-25%Ni-15%Cr austenitic alloys with various MX (M=V, Ti, Nb, Zr; X=C, N) stabilizers after helium implantation and creep rupture at 923 K. It is shown that suppression of helium embrittlement can be achieved through a higher dispersion density of incoherent precipitates because of their high capability of bubble entrapment. A good agreement between the average distance of grain boundary bubbles exceeding the minimum critical size and the spacing of cavity traces on intergranularly fractured surfaces is obtained. This suggests that the enhancement of grain boundary decohesion by helium is a result of unstable growth of super-critical helium bubbles.

  2. Localized ridge augmentation using autogenous block bone graft followed by dental implant placement

    Directory of Open Access Journals (Sweden)

    K V Prabhakara Rao

    2012-01-01

    Full Text Available The placement of endosseous dental implants is often hampered by unfavourable anatomy of the alveolar bone. Most frequently patients lose their teeth due to alveolar bone loss, tooth extraction; trauma and long term use of removable appliances tend to lose the bone making it difficult for the placement of implant in an optimal prosthetic position. The loss of width of the residual alveolar ridge necessitated measures which could refurbish the lost dimensions. Here we report the successful management of such a condition wherein placement of implant was made possible by placement of autogenous bone block graft obtained from the mandibular symphysis region and predictable osseointegration thus achieved.

  3. 57Fe-ion implantation in pulse laser deposited La0.75Ca0.25MnO3 films: Conversion electron Mössbauer spectroscopy and X-ray diffraction studies

    Indian Academy of Sciences (India)

    U D Lanke; J Prabhjyot Pal

    2000-02-01

    Oriented La0.75Ca0.25MnO3 (LCMO) films have been deposited by pulsed laser deposition (PLD) method on (100) LaAlO3 substrates. Ion-beam technique is used to introduce a very low concentration of 57Fe+ in LCMO film. The deposited films were subjected to 100 keV 57Fe+ implantation with different fluences at room temperature. The main motivation of this work was to study the influence of implantation on the transport mechanism in materials exhibiting colossal magnetoresistance (CMR) property. It is observed that Fe implantation drastically affects the structural and magneto-transport properties. The samples were characterized using the X-ray diffraction (XRD) technique, conversion electron Mössbauer spectroscopy (CEMS) and resistance temperature (–) measurements.

  4. Properties and local environment of p-type and photoluminescent rare earths implanted into ZnO single crystals

    CERN Document Server

    Rita, EMC; Wahl, U; Soares, JC

    This thesis presents an experimental study of the local environment of p-type and Rare- Earth dopants implanted in ZnO single-crystals (SCs). Various nuclear and bulk property techniques were combined in the following evaluations: Implantation damage annealing was evaluated in ZnO SCs implanted with Fe, Sr and Ca. P-type dopants Cu and Ag implanted ZnO SCs were studied revealing that the solubility of Cu in substituting Zn is considerably higher than that of Ag. These results are discussed within the scope of the ZnO p-type doping problematic with these elements. Experimental proofs of the As “anti-site” behavior in ZnO were for the first time attained, i.e., the majority of As atoms are substitutional at the Zn site (SZn), possibly surrounded by two Zn vacancies (VZn). This reinforces the theoretical prediction that As acts as an acceptor in ZnO via the AsZn-2VZn complex formation. The co-doping of ZnO SC with In (donor) and As (acceptor) was addressed. The most striking result is the possible In-As “p...

  5. [Force-based local navigation in robot-assisted implantation bed anlage in the lateral skull base. An experimental study].

    Science.gov (United States)

    Plinkert, P K; Federspil, P A; Plinkert, B; Henrich, D

    2002-03-01

    Excellent precision, miss of retiring, reproducibility are main characteristics of robots in the operating theatre. Because of these facts their use for surgery in the lateral scull base is of great interest. In recent experiments we determined process parameters for robot assisted reaming of a cochlea implant bed and for a mastoidectomy. These results suggested that optimizing parameters for thrilling with the robot is needed. Therefore we implemented a suitable reaming curve from the geometrical data of the implant and a force controlled process control for robot assisted reaming at the lateral scull base. Experiments were performed with an industrial robot on animal and human scull base specimen. Because of online force detection and feedback of sensory data the reaming with the robot was controlled. With increasing force values above a defined limit feed rates were automatically regulated. Furthermore we were able to detect contact of the thrill to dura mater by analyzing the force values. With the new computer program the desired implant bed was exactly prepared. Our examinations showed a successful reaming of an implant bed in the lateral scull base with a robot. Because of a force controlled reaming process locale navigation is possible and enables careful thrilling with a robot.

  6. Histologic, morphometric, and densitometric study of peri-implant bone in rabbits with local administration of growth hormone.

    Science.gov (United States)

    Tresguerres, Isabel F; Alobera, Miguel A; Baca, Rafael; Tresguerres, Jesús A F

    2005-01-01

    The objective of this study was to evaluate whether the local administration of growth hormone (GH) would influence the formation of peri-implant bone around titanium sheets placed in the tibiae of young rabbits. Thirty-two New Zealand rabbits were randomly placed in 1 of 2 groups: the experimental group, in which 4 IU (1.2 mg) of lyophilized powder (GH) was added to a surgically created defect at implant placement, or the control group, in which an implant sheet was placed without hormonal treatment. Animals were sacrificed at 1, 2, 3, and 6 weeks after surgery, and histologic sections were stained with Masson, Alcian blue, picrosirius, and hematoxylin-eosin and observed under light microscopy. The sections were analyzed morphometrically and densitometrically to calculate the amount of newly formed bone. At week 2, GH-group sections showed enhanced growth of the trabeculae from the periosteal tissue, with thicker and more irregular trabeculae than those observed in control group specimens. A tendency toward greater bone area and lesser density was observed in the GH group, although the groups did not differ significantly. Nevertheless, bone-to-implant contact in weeks 2 and 6 was significantly greater in the GH group (P < .05). An increase in the cortical response from periosteal and endosteal reactions was observed with the high local administration of GH, in disagreement with most authors. In the first phases of bone repair, the osteons were more disorganized; they were more organized by the sixth week. Local administration of GH could stimulate the first phases of the bone remodeling process in this experimental model.

  7. Atomic scale properties of magnetic Mn-based alloys probed by emission Mössbauer spectroscopy

    CERN Multimedia

    Mn-based alloys are characterized by a wealth of properties, which are of interest both from fundamental physics point of view and particularly attractive for different applications in modern technology: from magnetic storage to sensing and spin-based electronics. The possibility to tune their magnetic properties through post-growth thermal processes and/or stoichiometry engineering is highly important in order to target different applications (i.e. Mn$_{x}$Ga) or to increase their Curie temperature above room temperature (i.e. off-stoichiometric MnSi). In this project, the Mössbauer effect will be applied at $^{57}$Fe sites following implantation of radioactive $^{57}$Mn, to probe the micro-structure and magnetism of Mn-based alloys on the atomic-scale. The proposed experimental plan is devoted to establish a direct correlation between the local structure and bulk magnetism (and other physical properties) of Mn-based alloys.

  8. Temperature dependent evolution of the electronic and local atomic structure in the cubic colossal magnetoresistive manganite La1-xSrxMnO3

    Energy Technology Data Exchange (ETDEWEB)

    Arenholz, Elke; Mannella, N.; Booth, C.H.; Rosenhahn, A.; Sell, B.C.; Nambu, A.; Marchesini, S.; Mun, B. S.; Yang, S.-H.; Watanabe, M.; Ibrahim, K.; Arenholz, E.; Young, A.; Guo, J.; Tomioka, Y.; Fadley, C.S.

    2007-12-06

    We have studied the temperature-dependent evolution of the electronic and local atomic structure in the cubic colossal magnetoresistive manganite La{sub 1-x}Sr{sub x}MnO{sub 3} (x= 0.3-0.4) with core and valence level photoemission (PE), x-ray absorption spectroscopy (XAS), x-ray emission spectroscopy (XES), resonant inelastic x-ray scattering (RIXS), extended x-ray absorption fine structure (EXAFS) spectroscopy and magnetometry. As the temperature is varied across the Curie temperature T{sub c}, our PE experiments reveal a dramatic change of the electronic structure involving an increase in the Mn spin moment from {approx} 3 {micro}B to {approx} 4 {micro}B, and a modification of the local chemical environment of the other constituent atoms indicative of electron localization on the Mn atom. These effects are reversible and exhibit a slow-timescale {approx}200 K-wide hysteresis centered at T{sub c}. Based upon the probing depths accessed in our PE measurements, these effects seem to survive for at least 35-50 {angstrom} inward from the surface, while other consistent signatures for this modification of the electronic structure are revealed by more bulk sensitive spectroscopies like XAS and XES/RIXS. We interpret these effects as spectroscopic fingerprints for polaron formation, consistent with the presence of local Jahn-Teller distortions of the MnO{sub 6} octahedra around the Mn atom, as revealed by the EXAFS data. Magnetic susceptibility measurements in addition show typical signatures of ferro-magnetic clusters formation well above the Curie temperature.

  9. Comparing sound localization deficits in bilateral cochlear-implant users and vocoder simulations with normal-hearing listeners.

    Science.gov (United States)

    Jones, Heath; Kan, Alan; Litovsky, Ruth Y

    2014-11-10

    Bilateral cochlear-implant (BiCI) users are less accurate at localizing free-field (FF) sound sources than normal-hearing (NH) listeners. This performance gap is not well understood but is likely due to a combination of compromises in acoustic signal representation by the two independent speech processors and neural degradation of auditory pathways associated with a patient's hearing loss. To exclusively investigate the effect of CI speech encoding on horizontal-plane sound localization, the present study measured sound localization performance in NH subjects listening to vocoder processed and nonvocoded virtual acoustic space (VAS) stimuli. Various aspects of BiCI stimulation such as independently functioning devices, variable across-ear channel selection, and pulsatile stimulation were simulated using uncorrelated noise (Nu), correlated noise (N0), or Gaussian-enveloped tone (GET) carriers during vocoder processing. Additionally, FF sound localization in BiCI users was measured in the same testing environment for comparison. Distinct response patterns across azimuthal locations were evident for both listener groups and were analyzed using a multilevel regression analysis. Simulated implant speech encoding, regardless of carrier, was detrimental to NH localization and the GET vocoder best simulated BiCI FF performance in NH listeners. Overall, the detrimental effect of vocoder processing on NH performance suggests that sound localization deficits may persist even for BiCI patients who have minimal neural degradation associated with their hearing loss and indicates that CI speech encoding plays a significant role in the sound localization deficits experienced by BiCI users.

  10. Itinerant and localized magnetic moments in ferrimagnetic Mn{sub 2}CoGa thin films identified with x-ray magnetic linear dichroism: experiment and ab initio theory

    Energy Technology Data Exchange (ETDEWEB)

    Meinert, M.; Schmalhorst, J; Klewe, C.; Reiss, G.; Arenholz, E.; Bohnert, T.; Nielsch, K.

    2011-08-08

    Epitaxial thin films of the half-metallic X{sub a}-compound Mn{sub 2}CoGa (Hg{sub 2}CuTi prototype) were prepared by dc magnetron co-sputtering with different heat treatments on MgO (001) substrates. High-quality lms with a bulk magnetization of 1.95(5) {mu}{sub }B per unit cell were obtained. The average Mn magnetic moment and the Co moment are parallel, in agreement with theory. The x-ray magnetic circular dichroism spectra agree with calculations based on density functional theory and reveal the antiparallel alignment of the two inequivalent Mn moments. X-ray magnetic linear dichroism allows to distinguish between itinerant and localized Mn moments. It is shown that one of the two Mn moments has localized character, whereas the other Mn moment and the Co moment are itinerant.

  11. Fabrication of localizing template for extraoral implant in a patient with congenital defect in one ear

    Directory of Open Access Journals (Sweden)

    Susan Mir Mohammad Rezaei

    2014-01-01

    Full Text Available Introduction: The use of osseointegrated extraoral implants for retention of extraoral prostheses, such as ears offers ideal support and retention, and improves patient′s appearance and quality of life. However, the best result may be obtained only by careful planning number, position and orientation of the implants and this article presents a method of making of a surgical stent that is simple, economic and stable during all phases of surgery. Case Report: A 26-year-old male (without any remarkable systemic disorder presented with congenital defect in one ear. An impression was made of congenital defect in left ear, wax pattern of defect and missing ear is made, the wax prosthesis is changed into a clear acrylic resin, and on the other hand an occlusal maxillary splint is also fabricated with clear acrylic resin. The occlusal splint and the acrylic resin ear are joined together using an extraoral bar that is made of proper length of wax and also is checked on patient′s face and processed into a clear acrylic resin. Discussion: By this kind of surgical guide, we can determine the best location of the implants and location of the implants will not compromise to fabricate ear prostheses with ideal form and location. This surgical guide can be used for the pretreatment of radiographic stent.

  12. Cataract surgery with intraocular lens implantation in children aged 5-15 in local anaesthesia: visual outcomes and complications.

    Science.gov (United States)

    Giles, Kagmeni; Christelle, Domngang; Yannick, Bilong; Fricke, Otto Herrmann; Wiedemann, Peter

    2016-01-01

    The aim of this study was to report feasibility, the visual outcomes and complications of pediatric cataract surgery with primary intraocular lens implantation in children aged 5 to15 years in local anesthesia. This retrospective interventional case series included 62 eyes from 50 children who underwent pediatrc cataract surgery with primary intraocular lens implantation at the Mana eye Clinic Nkongsamba between 2006 and 2015 Main outcome measures were: best-corrected post operative visual acuity, and intraoperative and postoperative complications. Mean age at surgery was 10.18 ± 3.21 years. Mean follow up length was 15.75 ± 3.36 weeks. Etiology included: 10 congenital cataracs (16.12%). 35 developmental cataracts (56.45%) and 17 traumatic cataracts (27.41%). The mean preoperative BCVA was logMAR 1.19 ± 0.33. (range 0.6-2.3). After cycloplegia refraction 2 weeks after surgery, the mean postoperative BCVA was log MAR 0.58 ± 0.88 ( range 0.5-1.8). The mean implanted IOL power was 22.01 ±3.16 D. IOL was succefuly implanted in 54 eyes (87.07%). Eight eyes (9.67%) were left aphakic. Increase in BCVA of 4 logMAR lines and above was recorded in 27 patients (43.55%). Intraoperative complications included: 4 posterior capsule holes with vitrous lost, 3 lenses subluxation and 1 case of iris dialyse. Late postoperative complications included: posterior capsular opacity which occurred in 16 patients, 3 posterior synechia, 2 retinal detachment. Peribulbar anaesthesia can be considered as a viable option in selected patients presenting developmental cataract undergoing cataract surgery in developing countries. Effort should be made to improve the early identification of congenital cataract and its early surgical intervention and prompt optical rehabilitation to prevent amblyopia.

  13. MN15-L: A New Local Exchange-Correlation Functional for Kohn-Sham Density Functional Theory with Broad Accuracy for Atoms, Molecules, and Solids.

    Science.gov (United States)

    Yu, Haoyu S; He, Xiao; Truhlar, Donald G

    2016-03-08

    Kohn-Sham density functional theory is widely used for applications of electronic structure theory in chemistry, materials science, and condensed-matter physics, but the accuracy depends on the quality of the exchange-correlation functional. Here, we present a new local exchange-correlation functional called MN15-L that predicts accurate results for a broad range of molecular and solid-state properties including main-group bond energies, transition metal bond energies, reaction barrier heights, noncovalent interactions, atomic excitation energies, ionization potentials, electron affinities, total atomic energies, hydrocarbon thermochemistry, and lattice constants of solids. The MN15-L functional has the same mathematical form as a previous meta-nonseparable gradient approximation exchange-correlation functional, MN12-L, but it is improved because we optimized it against a larger database, designated 2015A, and included smoothness restraints; the optimization has a much better representation of transition metals. The mean unsigned error on 422 chemical energies is 2.32 kcal/mol, which is the best among all tested functionals, with or without nonlocal exchange. The MN15-L functional also provides good results for test sets that are outside the training set. A key issue is that the functional is local (no nonlocal exchange or nonlocal correlation), which makes it relatively economical for treating large and complex systems and solids. Another key advantage is that medium-range correlation energy is built in so that one does not need to add damped dispersion by molecular mechanics in order to predict accurate noncovalent binding energies. We believe that the MN15-L functional should be useful for a wide variety of applications in chemistry, physics, materials science, and molecular biology.

  14. Receptor Activator of Nuclear Factor Kappa-B Ligand-Induced Local Osteoporotic Canine Mandible Model for the Evaluation of Peri-Implant Bone Regeneration.

    Science.gov (United States)

    Chang, Ah Ryum; Cho, Tae Hyung; Hwang, Soon Jung

    2017-08-24

    The canine mandible is useful for studying bone regeneration after dental implant placement. However, it is limited in investigations of peri-implant osteogenesis under osteoporotic conditions due to the insignificant osteoporotic effect of ovariectomy. This study aimed at establishing a local osteoporotic model without ovariectomy by using receptor activator of nuclear factor kappa-B ligand (RANKL) in a canine mandible model. This new model was used to evaluate the effects of injectable β-tricalcium phosphate (TCP) microsphere bone grafts on peri-implant bone regeneration under osteoporotic conditions with combinations of recombinant human bone morphogenetic protein-2 (rhBMP-2). A local osteoporotic canine mandible model was designed by creating a hole in the mandibular alveolar bone, then implanting a collagen sponge soaked with 20, 40, or 60 μg RANKL into the hole, and leaving it for 2 weeks. After the establishment of the dose for maximum osteoporotic bone loss at 40 μg of RANKL, the main surgery was performed. RANKL-soaked collagen sponges were removed, and dental implants were placed with bone grafts in five groups: implant only, TCP, and TCP + rhBMP-2 at 5, 15, and 45 μg. Peri-implant bone generation was determined by radiologic and histologic evaluations at 6 weeks after dental implant placement. On performing micro-computed tomography analysis, the group with TCP + 5 μg rhBMP-2 showed the highest bone volume than the other groups and a 22% increase (p model was useful for peri-implant bone regeneration under osteoporotic conditions such as those found in geriatric patients. The injectable β-TCP bone grafts used in this study were effective in peri-implant bone generation under osteoporotic conditions, and their efficiency was enhanced at 5 μg BMP-2 compared with higher concentrations of BMP-2.

  15. New procedure of quantitative mapping of Ti and Al released from dental implant and Mg, Ca, Fe, Zn, Cu, Mn as physiological elements in oral mucosa by LA-ICP-MS.

    Science.gov (United States)

    Sajnóg, Adam; Hanć, Anetta; Koczorowski, Ryszard; Barałkiewicz, Danuta

    2017-12-01

    A new procedure for determination of elements derived from titanium implants and physiological elements in soft tissues by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is presented. The analytical procedure was developed which involved preparation of in-house matrix matched solid standards with analyte addition based on certified reference material (CRM) MODAS-4 Cormorant Tissue. Addition of gelatin, serving as a binding agent, essentially improved physical properties of standards. Performance of the analytical method was assayed and validated by calculating parameters like precision, detection limits, trueness and recovery of analyte addition using additional CRM - ERM-BB184 Bovine Muscle. Analyte addition was additionally confirmed by microwave digestion of solid standards and analysis by solution nebulization ICP-MS. The detection limits are in range 1.8μgg(-1) to 450μgg(-1) for Mn and Ca respectively. The precision values range from 7.3% to 42% for Al and Zn respectively. The estimated recoveries of analyte addition line within scope of 83%-153% for Mn and Cu respectively. Oral mucosa samples taken from patients treated with titanium dental implants were examined using developed analytical method. Standards and tissue samples were cryocut into 30µm thin sections. LA-ICP-MS allowed to obtain two-dimensional maps of distribution of elements in tested samples which revealed high content of Ti and Al derived from implants. Photographs from optical microscope displayed numerous particles with µm size in oral mucosa samples which suggests that they are residues from implantation procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Combined use of transverse and scout computed tomography scans to localize radioactive seeds in an interstitial brachytherapy implant.

    Science.gov (United States)

    Yue, N; Chen, Z; Bond, J E; Son, Y H; Nath, R

    1999-04-01

    Various techniques have been developed to localize radioactive sources in brachytherapy implants. The most common methods include the orthogonal film method, the stereo-shift film method, and recently, direct localization from a series of contiguous CT transverse images. The major advantage of the CT method is that it provides the seed locations relative to anatomic structures. However, it is often the case that accurate identification and localization of the sources become difficult because of partial source artifacts in more than one transverse cut and other artifacts on CT images. A new algorithm has been developed to combine the advantages of using a pair of orthogonal scout views with the advantages of using a stack of transverse cuts. In the new algorithm, a common reference point is used to correlate CT transverse images and two orthogonal scout CT scans (AP and lateral). The radioactive sources are localized on CT transverse images. At the same time, the sources are displayed automatically on the two CT scout scans. In this way, the individual sources can be clearly distinguished and ambiguities arising from partial source artifacts are resolved immediately. Because of the finite slice thickness of transverse cuts, the longitudinal coordinates are more accurately obtained from the scout views. Therefore, the longitudinal coordinates of seeds localized on the transverse cuts are adjusted so that they match the position of the seeds on scout views. The algorithm has been tested on clinical cases and has proved to be a time saving and accurate method.

  17. Implantation of venous access devices under local anesthesia: patients’ satisfaction with oral lorazepam

    Directory of Open Access Journals (Sweden)

    Chang DH

    2015-07-01

    Full Text Available De-Hua Chang,1 Sonja Hiss,1 Lena Herich,2 Ingrid Becker,2 Kamal Mammadov,1 Mareike Franke,1 Anastasios Mpotsaris,1 Robert Kleinert,3 Thorsten Persigehl,1 David Maintz,1 Christopher Bangard1 1Department of Radiology, 2Institute of Medical Statistics, Informatics and Epidemiology, 3Department of Surgery, University Hospital of Cologne, Cologne, Germany Objective: The aim of the study reported here was to evaluate patients’ satisfaction with implantation of venous access devices under local anesthesia (LA with and without additional oral sedation.Materials and methods: A total of 77 patients were enrolled in the prospective descriptive study over a period of 6 months. Subcutaneous implantable venous access devices through the subclavian vein were routinely implanted under LA. Patients were offered an additional oral sedative (lorazepam before each procedure. The level of anxiety/tension, the intensity of pain, and patients’ satisfaction were evaluated before and immediately after the procedure using a visual analog scale (ranging from 0 to 10 with a standardized questionnaire.Results: Patients’ satisfaction with the procedure was high (mean: 1.3±2.0 with no significant difference between the group with premedication and the group with LA alone (P=0.54. However, seven out of 30 patients (23.3% in the group that received premedication would not undergo the same procedure without general anesthesia. There was no significant influence of lorazepam on the intensity of pain (P=0.88. In 12 out of 30 patients (40% in the premedication group, the level of tension was higher than 5 on the visual analog scale during the procedure. In 21 out of 77 patients (27.3%, the estimate of the level of tension differed between the interventionist and the patient by 3 or more points in 21 out of 77 patients (27.3%.Conclusion: Overall patient satisfaction is high for implantation of venous access devices under LA. A combination of LA with lorazepam administered

  18. Defect induced changes on the excitation transfer dynamics in ZnS/Mn nanowires

    Directory of Open Access Journals (Sweden)

    Geburt Sebastian

    2011-01-01

    Full Text Available Abstract Transients of Mn internal 3d 5 luminescence in ZnS/Mn nanowires are strongly non-exponential. This non-exponential decay arises from an excitation transfer from the Mn ions to so-called killer centers, i.e., non-radiative defects in the nanostructures and is strongly related to the interplay of the characteristic length scales of the sample such as the spatial extensions, the distance between killer centers, and the distance between Mn ions. The transients of the Mn-related luminescence can be quantitatively described on the basis of a modified Förster model accounting for reduced dimensionality. Here, we confirm this modified Förster model by varying the number of killer centers systematically. Additional defects were introduced into the ZnS/Mn nanowire samples by irradiation with neon ions and by varying the Mn implantation or the annealing temperature. The temporal behavior of the internal Mn2+ (3d 5 luminescence is recorded on a time scale covering almost four orders of magnitude. A correlation between defect concentration and decay behavior of the internal Mn2+ (3d 5 luminescence is established and the energy transfer processes in the system of localized Mn ions and the killer centers within ZnS/Mn nanostructures is confirmed. If the excitation transfer between Mn ions and killer centers as well as migration effects between Mn ions are accounted for, and the correct effective dimensionality of the system is used in the model, one is able to describe the decay curves of ZnS/Mn nanostructures in the entire time window.

  19. MeV Si ion beam implantation as an effective patterning tool for the localized formation of porous silicon

    Energy Technology Data Exchange (ETDEWEB)

    Punzon-Quijorna, E., E-mail: esther.punzon@uam.es [Universidad Autonoma de Madrid, Dept. Fisica Aplicada C-XII-104, 28049, Madrid (Spain); Centro de Micro-Analisis de Materiales, Cantoblanco 28049, Madrid (Spain); Torres-Costa, V.; Manso-Silvan, M.; Martin-Palma, R.J. [Universidad Autonoma de Madrid, Dept. Fisica Aplicada C-XII-104, 28049, Madrid (Spain); Climent-Font, A. [Universidad Autonoma de Madrid, Dept. Fisica Aplicada C-XII-104, 28049, Madrid (Spain); Centro de Micro-Analisis de Materiales, Cantoblanco 28049, Madrid (Spain)

    2012-07-01

    Porous silicon (PS), in the form of single layer and multilayer structures, is a low-cost nanomaterial with applications in a wide range of fields. Hence, there is an increasing interest on the fabrication of laterally patterned PS structures. In biophysics for example, PS is a promising material for the development of low cost optical biochips, due to its remarkable biocompatibility and adjustable surface chemistry and optical properties. However, conventional lithography processes have shown to be not suitable for the proper patterning of PS. In this work, implantation of MeV Si ions is proposed as an effective tool for the localized formation of PS in the micrometer range. As previously reported by other groups, irradiation of silicon with H and He keV ions can inhibit the formation of PS. In the case of heavier ions, its higher damage efficiency allows for lower implantation doses to achieve PS growth inhibition, which allows shorter process times, and at the same time provides good lateral resolution below the micrometric range. Besides, the usage of ions of the same elementary nature as the target material avoids inconvenient side effects that may be ascribed to the implanted species. Two dimensional PS patterns with feature size of few micrometers have been successfully fabricated. Fluorescence and scanning electron microscopy reveal the proper transfer of different mask motifs into a PS/silicon patterned structure. Patterns present well defined lateral contrast and flat surface with no significant height variations, mandatory features for the development of PS based biochips. A resistivity increase has been observed on irradiated samples which could explain the inhibition of PS formation. This effect is attributed to dopant deactivation by the ion beam, since backscattering channeling measurements show no significant lattice damage.

  20. Acute and chronic local inflammatory reaction after implantation of different extracellular porcine dermis collagen matrices in rats.

    Science.gov (United States)

    Lucke, Silke; Hoene, Andreas; Walschus, Uwe; Kob, Anette; Pissarek, Jens-Wolfgang; Schlosser, Michael

    2015-01-01

    Two cross-linked acellular porcine dermal collagen matrices (Permacol and NRX) were implanted into rats and the acute and chronic local inflammatory tissue reactions were investigated after 7, 14, 28, and 112 days. Both membranes were stable in vivo for up to 112 days. All investigated immune cell populations (CD68+ macrophages, CD163+ macrophages, T lymphocytes, MHC class II positive cells, mast cells, and NK cells) were present. Their amount decreased significantly over time compared to day 7 after implantation. A change from an acute to a chronic inflammation and an associated shift from proinflammatory M1-like to anti-inflammatory M2-like macrophages were observed. In the early phase there was a significant correlation of T cells to CD68+ (M1-like) macrophages, whereas in the chronic phase T lymphocytes were positively correlated with CD163+ (M2-like) macrophages. The material NRX showed an enhanced inflammatory reaction in comparison to Permacol possibly caused by material characteristics such as a twofold higher thickness of the membrane, roughness, and water absorption capacity. Nevertheless, a more pronounced regenerative process as, for example, indicated by nestin expression demonstrated its possible suitability for applications as wound repair material.

  1. Acute and Chronic Local Inflammatory Reaction after Implantation of Different Extracellular Porcine Dermis Collagen Matrices in Rats

    Directory of Open Access Journals (Sweden)

    Silke Lucke

    2015-01-01

    Full Text Available Two cross-linked acellular porcine dermal collagen matrices (Permacol and NRX were implanted into rats and the acute and chronic local inflammatory tissue reactions were investigated after 7, 14, 28, and 112 days. Both membranes were stable in vivo for up to 112 days. All investigated immune cell populations (CD68+ macrophages, CD163+ macrophages, T lymphocytes, MHC class II positive cells, mast cells, and NK cells were present. Their amount decreased significantly over time compared to day 7 after implantation. A change from an acute to a chronic inflammation and an associated shift from proinflammatory M1-like to anti-inflammatory M2-like macrophages were observed. In the early phase there was a significant correlation of T cells to CD68+ (M1-like macrophages, whereas in the chronic phase T lymphocytes were positively correlated with CD163+ (M2-like macrophages. The material NRX showed an enhanced inflammatory reaction in comparison to Permacol possibly caused by material characteristics such as a twofold higher thickness of the membrane, roughness, and water absorption capacity. Nevertheless, a more pronounced regenerative process as, for example, indicated by nestin expression demonstrated its possible suitability for applications as wound repair material.

  2. Crystallographic analysis of the implanted TiNi monocrystal containing misoriented localized shear mesobands in its near-surface layer [001]{sub B2}

    Energy Technology Data Exchange (ETDEWEB)

    Meisner, L. L., E-mail: llm@ispms.tsc.ru; Meisner, S. N., E-mail: msn@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation); National Research Tomsk State University, Tomsk, 634050 (Russian Federation); Tverdokhlebova, A. V., E-mail: a@vtverd.ru; Poletika, T. M., E-mail: poletm@ispms.tsc.ru; Girsova, S. L., E-mail: girs@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation)

    2015-10-27

    The study was carried on for the implanted single TiNi crystal containing misoriented localized shear mesobands in its near-surface layer [001] B2. Due to the response of material to the Si ion implantation treatment of the single TiNi crystal, deformation mesobands would form in its near-surface layer. Specially designed software tools were employed for the treatment of experimental data obtained from X-ray and electron diffraction patterns. The 3D crystallographic orientations were calculated for the localized shear regions, which were displaced relative to one another and with respect to the original monocrystal orientation.

  3. Hybrid coating on a magnesium alloy for minimizing the localized degradation for load-bearing biodegradable mini-implant applications

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, M. Bobby, E-mail: bobby.mathan@jcu.edu.au; Liyanaarachchi, S.

    2013-10-01

    The effect of a hybrid coating, calcium phosphate (CaP) + polylactic acid (PLA), on a magnesium alloy on its in vitro degradation (general and localized) behaviour was studied for potential load-bearing biodegradable mini-implant applications. CaP was coated on a magnesium alloy, AZ91, using an electrochemical deposition method. A spin coating method was used to coat PLA on the CaP coated alloy. In vitro degradation performance of the alloy with hybrid coating was evaluated using electrochemical impedance spectroscopy (EIS) in simulated body fluid (SBF). The EIS results showed that the hybrid coating enhanced the degradation resistance of the alloy by more than two-order of magnitude as compared to the bare alloy and one-order of magnitude higher than that of the CaP coated alloy, after 1 h exposure in simulated body fluid (SBF). Long-term (48 h) EIS results also confirmed that the hybrid coating performed better than the bare alloy and the CaP coated alloy. Importantly, the hybrid coating improved the localized degradation resistance of the alloy significantly, which is critical for better in service mechanical integrity. - Highlights: • A hybrid coating (CaP + PLA) was applied on a magnesium-based alloy. • The hybrid coating enhanced the in vitro degradation resistance of the alloy. • Localized degradation resistance was also improved by the hybrid coating.

  4. Low-temperature localization in the transport properties of self-doped La$_{0.9}$Mn$_{0.98}$Zn$_{0.02}$O$_3$

    Indian Academy of Sciences (India)

    K De; S Das

    2016-02-01

    Low-temperature transport properties are investigated in the self-doped compound, La$_{0.9}$Mn$_{0.98}$Zn$_{0.02}$O$_3$. The analysis of the low-temperature resistivity is performed considering various scattering mechanisms. The parameters involved with different scattering processes such as electron–electron, Kondo, electron–phonon and electron–magnon are found to be strongly influenced by the applied magnetic field. The results suggest that interplay between electron–electron and Kondo-like scatterings lead to the localization in the temperature dependence of resistivity at low temperature.

  5. Localization of vascular endothelial growth factor (VEGF) and its receptors VEGFR-1 and VEGFR-2 in bovine placentomes from implantation until term

    DEFF Research Database (Denmark)

    Pfarrer, C.D.; Ruziwa, S.D.; Winther, H.

    2006-01-01

    epithelium. An antibody against bovine VEGF revealed a strong reactivity in the stroma of maternal caruncular septa in early and mid-gestation, which distinctly decreased near term. In interplacentomal areas, VEGF was found in luminal and glandular epithelia as well as in trophoblast, with distinctly higher...... term were evaluated by immunohistochemistry. VEGF immunoreactivity was detected in fetal and maternal blood vessel tissues during implantation and throughout gestation, and in preimplantatory trophoblast cells and uterine epithelium. After implantation the immunoreaction was confined to TGC and uterine...... reactivity in giant cells. VEGFR-1 was observed in trophoblast and uterine epithelium around implantation. Later, in definite placentomes, VEGFR-1 was localized in TGC near the chorionic plate and in maternal endothelial cells in the center of the placentome. VEGFR-1 and VEGFR-2 were co-localized in uterine...

  6. Horizontal sound localization in cochlear implant users with a contralateral hearing aid

    NARCIS (Netherlands)

    Veugen, L.C.E.; Hendrikse, M.M.E.; van Wanrooij, M.M.; Agterberg, M.J.H.; Chalupper, J.; Mens, L.H.M; Snik, A.F.M.; Opstal, A.J. van

    2016-01-01

    Interaural differences in sound arrival time (ITD) and in level (ILD) enable us to localize sounds in the horizontal plane, and can support source segregation and speech understanding in noisy environments. It is uncertain whether these cues are also available to hearing-impaired listeners who are

  7. Local atomic and magnetic structure of dilute magnetic semiconductor (Ba,K)(Zn,Mn)$_2$As$_2$

    OpenAIRE

    Frandsen, Benjamin A.; Gong, Zizhou; Terban, Maxwell W.; Banerjee, Soham; Chen, Bijuan; Jin, Changqing; Feygenson, Mikhail; Uemura, Yasutomo J.; Billinge, Simon J. L.

    2016-01-01

    We have studied the atomic and magnetic structure of the dilute ferromagnetic semiconductor system (Ba,K)(Zn,Mn)$_2$As$_2$ through atomic and magnetic pair distribution function analysis of temperature-dependent x-ray and neutron total scattering data. We detected a change in curvature of the temperature-dependent unit cell volume of the average tetragonal crystallographic structure at a temperature coinciding with the onset of ferromagnetic order. We also observed the existence of a well-def...

  8. Three-dimensional localization of implanted biomaterials in anatomical and histological specimens using combined X-ray computed tomography and three-dimensional surface reconstruction: a technical note.

    NARCIS (Netherlands)

    Cuijpers, V.M.J.I.; Walboomers, X.F.; Jansen, J.A.

    2010-01-01

    For adequate histological processing of implanted biomaterials or tissue-engineered constructs, it is sometimes essential to obtain insight into the localization of structures inside the tissue samples. Observation of three-dimensional (3D) surface reconstruction, including basic photorealistic text

  9. Quantification of local hemodynamic alterations caused by virtual implantation of three commercially available stents for the treatment of aortic coarctation.

    Science.gov (United States)

    Kwon, Sung; Feinstein, Jeffrey A; Dholakia, Ronak J; Ladisa, John F

    2014-04-01

    Patients with coarctation of the aorta (CoA) are prone to morbidity including atherosclerotic plaque that has been shown to correlate with altered wall shear stress (WSS) in the descending thoracic aorta (dAo). We created the first patient-specific computational fluid dynamics (CFD) model of a CoA patient treated by Palmaz stenting to date, and compared resulting WSS distributions to those from virtual implantation of Genesis XD and modified NuMED CP stents, also commonly used for CoA. CFD models were created from magnetic resonance imaging, fluoroscopy and blood pressure data. Simulations incorporated vessel deformation, downstream vascular resistance and compliance to match measured data and generate blood flow velocity and time-averaged WSS (TAWSS) results. TAWSS was quantified longitudinally and circumferentially in the stented region and dAo. While modest differences were seen in the distal portion of the stented region, marked differences were observed downstream along the posterior dAo and depended on stent type. The Genesis XD model had the least area of TAWSS values exceeding the threshold for platelet aggregation in vitro, followed by the Palmaz and NuMED CP stents. Alterations in local blood flow patterns and WSS imparted on the dAo appear to depend on the type of stent implanted for CoA. Following confirmation in larger studies, these findings may aid pediatric interventional cardiologists in selecting the most appropriate stent for each patient, and ultimately reduce long-term morbidity following treatment for CoA by stenting.

  10. Enhancement of localization phenomena driven by covalency in the SrBiMn{sub 1.75}Ti{sub 0.25}O{sub 6} manganite

    Energy Technology Data Exchange (ETDEWEB)

    Asensio de Lucas, E.; Alvarez-Serrano, I. [Depto. Quimica Inorganica I, Facultad Ciencias Quimicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Cuello, G.J. [Institut Laue-Langevin, 6 rue Jules Horowitz, F-38042 Grenoble (France); Garcia-Hernandez, M. [Instituto de Ciencia de Materiales de Madrid, CSIC, E-28049 Cantoblanco, Madrid (Spain); Lopez, M.L., E-mail: marisal@quim.ucm.es [Depto. Quimica Inorganica I, Facultad Ciencias Quimicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Pico, C.; Veiga, M.L. [Depto. Quimica Inorganica I, Facultad Ciencias Quimicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain)

    2012-05-05

    Graphical abstract: Enhancement of localization phenomena driven by covalency in the BiSrMn{sub 1.75}Ti{sub 0.25}O{sub 6} manganite. The CO/OO phenomena and magnetic clusters (Mn{sub 4}) stabilization at temperatures up to 520 K in BiSrMn{sub 1.75}Ti{sub 0.25}O{sub 6} are connected to a structural transition. The observed enhancement of electronic localization is interpreted considering covalent effects of Ti{sup 4+} and Bi{sup 3+} cations as the main driving force. Highlights: Black-Right-Pointing-Pointer The structural, electronic and magnetic behaviour of the new SrBiMn{sub 1.75}Ti{sub 0.25}O{sub 6} manganite is reported. Black-Right-Pointing-Pointer A structural transition above 520 K takes place, coinciding with relevant changes in the transport properties. Black-Right-Pointing-Pointer The electronic behavior is interpreted in terms of a remarkably high orbital and charge ordering temperature and cluster models. Black-Right-Pointing-Pointer The observed features are explained considering a scenario in which bonds covalence is enhanced by the Bi{sup 3+} and Ti{sup 4+} cations. - Abstract: Manganites are materials that show remarkable phenomena related to charge orbital ordering (CO/OO) and it is extremely important to understand the fundamental nature of this behaviour. This paper reports on the structural, electronic and magnetic behaviour of the new SrBiMn{sub 1.75}Ti{sub 0.25}O{sub 6} manganite and the dependence of these properties with temperature. A detailed structural analysis has been carried out by electron, X-ray, neutron diffraction between 4 and 700 K. The electron diffraction patterns obtained at room temperature (RT) evidence that the average structure (a{approx}b{approx}{radical}(2)a{sub p} and c {approx} 2a{sub p}) presents a modulation that doubles the a and c lattice parameters. A very high charge ordering (CO) transition temperature of 510 K, similar to that found for the non-doped material, SrBiMn{sub 2}O{sub 6}, is observed. Above this

  11. Paclitaxel loaded biodegradable poly (sebacic acid-co-ricinoleic acid cylindrical implants for local delivery-in vitro characterization

    Directory of Open Access Journals (Sweden)

    Jagadeesh G Hiremath

    2013-01-01

    Full Text Available The aim of the present research work was to develop the biodegradable polymeric implant for the delivery of antineoplastic drug, paclitaxel (PTX using poly (sebacic-co-recinoleic acid 70:30 w/w. PTX loaded implants were prepared by indigenously developed melt molding technique. Implants were characterized in terms of physico-chemical evaluations, drug content, drug stability and intactness, thermal analysis, drug physical state and crystallinity, surface morphology, hydrolytic degradation, drug release and its kinetics. Prepared implants were yellow and cylindrical in shape with smooth surfaces. Drug in the implants was found to be stable, intact and uniformly dispersed as amorphous state within the polymer matrix. In vitro release, kinetic studies showed zero order and Korsmeyer-Peppas model release being exhibited. Drug release from the polymeric implants was occurred could be as results of diffusion.

  12. The local environment of cobalt in amorphous, polycrystalline and epitaxial anatase TiO{sub 2}:Co films produced by cobalt ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Yildirim, O. [Helmholtz-Zentrum Dresden - Rossendorf, Institute of Ion Beam Physics and Materials Research, Bautzner Landstr. 400, 01328 Dresden (Germany); Technische Universität Dresden, D-01062 Dresden (Germany); Cornelius, S.; Hübner, R.; Potzger, K. [Helmholtz-Zentrum Dresden - Rossendorf, Institute of Ion Beam Physics and Materials Research, Bautzner Landstr. 400, 01328 Dresden (Germany); Smekhova, A.; Zykov, G.; Gan' shina, E. A.; Granovsky, A. B. [Lomonosov Moscow State University (MSU), Faculty of Physics, 119991 Moscow (Russian Federation); Bähtz, C. [Helmholtz-Zentrum Dresden - Rossendorf, Institute of Ion Beam Physics and Materials Research, Bautzner Landstr. 400, 01328 Dresden (Germany); Rossendorf Beamline, European Synchrotron Radiation Facility, F-38043 Grenoble (France)

    2015-05-14

    Amorphous, polycrystalline anatase and epitaxial anatase TiO{sub 2} films have been implanted with 5 at. % Co{sup +}. The magnetic and structural properties of different microstructures of TiO{sub 2}:Co, along with the local coordination of the implanted Co atoms within the host lattice are investigated. In amorphous TiO{sub 2}:Co film, Co atoms are in the (II) oxidation state with a complex coordination and exhibit a paramagnetic response. However, for the TiO{sub 2}:Co epitaxial and polycrystalline anatase films, Co atoms have a distorted octahedral (II) oxygen coordination assigned to a substitutional environment with traces of metallic Co clusters, which gives a rise to a superparamagnetic behavior. Despite the incorporation of the implanted atoms into the host lattice, high temperature ferromagnetism is absent in the films. On the other hand, it is found that the concentration and size of the implantation-induced nanoclusters and the magnetic properties of TiO{sub 2}:Co films have a strong dependency on the initial microstructure of TiO{sub 2}. Consequently, metallic nanocluster formation within ion implantation prepared transition metal doped TiO{sub 2} can be suppressed by tuning the film microstructure.

  13. A modified blister test to study the adhesion of thin coatings based on local helium ion implantation

    NARCIS (Netherlands)

    Galindo, RE; van Veen, A; Evans, JH; Schut, H; de Hosson, JTM

    2005-01-01

    A modified blister test has been developed based on helium ion implantation into selected areas of the metal substrate prior to the coating deposition. After a post-deposition thermal annealing, blisters are formed by agglomeration of the implanted gas at the ceramic-metal interface. This method can

  14. Back-junction back-contact n-type silicon solar cell with diffused boron emitter locally blocked by implanted phosphorus

    Science.gov (United States)

    Müller, Ralph; Schrof, Julian; Reichel, Christian; Benick, Jan; Hermle, Martin

    2014-09-01

    The highest energy conversion efficiencies in the field of silicon-based photovoltaics have been achieved with back-junction back-contact (BJBC) silicon solar cells by several companies and research groups. One of the most complex parts of this cell structure is the fabrication of the locally doped p- and n-type regions, both on the back side of the solar cell. In this work, we introduce a process sequence based on a synergistic use of ion implantation and furnace diffusion. This sequence enables the formation of all doped regions for a BJBC silicon solar cell in only three processing steps. We observed that implanted phosphorus can block the diffusion of boron atoms into the silicon substrate by nearly three orders of magnitude. Thus, locally implanted phosphorus can be used as an in-situ mask for a subsequent boron diffusion which simultaneously anneals the implanted phosphorus and forms the boron emitter. BJBC silicon solar cells produced with such an easy-to-fabricate process achieved conversion efficiencies of up to 21.7%. An open-circuit voltage of 674 mV and a fill factor of 80.6% prove that there is no significant recombination at the sharp transition between the highly doped emitter and the highly doped back surface field at the device level.

  15. Back-junction back-contact n-type silicon solar cell with diffused boron emitter locally blocked by implanted phosphorus

    Energy Technology Data Exchange (ETDEWEB)

    Müller, Ralph, E-mail: ralph.mueller@ise.fraunhofer.de; Schrof, Julian; Reichel, Christian; Benick, Jan; Hermle, Martin [Fraunhofer Institute for Solar Energy Systems, Heidenhofstrasse 2, Freiburg D-79110 (Germany)

    2014-09-08

    The highest energy conversion efficiencies in the field of silicon-based photovoltaics have been achieved with back-junction back-contact (BJBC) silicon solar cells by several companies and research groups. One of the most complex parts of this cell structure is the fabrication of the locally doped p- and n-type regions, both on the back side of the solar cell. In this work, we introduce a process sequence based on a synergistic use of ion implantation and furnace diffusion. This sequence enables the formation of all doped regions for a BJBC silicon solar cell in only three processing steps. We observed that implanted phosphorus can block the diffusion of boron atoms into the silicon substrate by nearly three orders of magnitude. Thus, locally implanted phosphorus can be used as an in-situ mask for a subsequent boron diffusion which simultaneously anneals the implanted phosphorus and forms the boron emitter. BJBC silicon solar cells produced with such an easy-to-fabricate process achieved conversion efficiencies of up to 21.7%. An open-circuit voltage of 674 mV and a fill factor of 80.6% prove that there is no significant recombination at the sharp transition between the highly doped emitter and the highly doped back surface field at the device level.

  16. Ti substituted La{sub 0.67}Ca{sub 0.33}MnO{sub 3} ortho-perovskites: Dominant role of local structure on the electrical transport and magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Seetha Lakshmi, L. [XS and CGS, Materials Science Division, Indira Gandhi Centre For Atomic Research, Kalpakkam, 603102 Tamil Nadu (India)], E-mail: slaxmi73@gmail.com; Rawat, R. [UGC-DAE Consortium for Scientific Research, Khandwa Road, Indore 452 017, Madhya Pradesh (India); Sridharan, V.; Sastry, V.S. [XS and CGS, Materials Science Division, Indira Gandhi Centre For Atomic Research, Kalpakkam, 603102 Tamil Nadu (India)

    2008-02-15

    We report the effects of local structure on the electrical transport and magnetic properties of La{sub 0.67}Ca{sub 0.33}Mn{sub 1-x}Ti{sub x}O{sub 3} (0{<=}x{<=}0.10) system. Linear increase in the lattice parameters, consequent expansion of unit cell and a monotonic decrease in the relative Mn{sup 4+} concentration with x suggest that Ti{sup 4+} predominantly replaces Mn{sup 4+} in La{sub 0.67}Ca{sub 0.33}Mn{sub 1-x}Ti{sub x}O{sub 3} (x{<=}0.10). The ferromagnetic-metallic ground state modifies to a glassy insulator for x{>=}0.05. No field induced metallic state could be discerned for x=0.10 even at a field of 8 T and at as low a temperature as 4.2 K. Ti substitution significantly enhances the colossal magnetoresistance (CMR) effect. Both the metal to insulator transition temperature and Curie temperature (T{sub c}) decrease at a rate of {approx}26 K/at% up to x=0.05. T{sub c} levels off for higher compositions. Modification of the major carrier concentration (decreased Mn{sup 4+} concentration) seems to be insufficient to account for the observed reduction in the transition temperatures. This in turn emphasizes the significance of local structural effects: systematic elongation of the Mn-O bond lengths and decrease of Mn-O-Mn angles leading to strong suppression of itinerant ferromagnetism and metallicity of the compounds. The additional features in the ac susceptibility, viz., a broad shoulder just below T{sub c} followed by a sharp decrease in the susceptibility signal at low temperatures and a non-closure of MR at zero field as high as {approx}75% at 5 K indicate a frustrated magnetic ground state for x=0.07. Based on the inter-comparison of the structural, electrical transport and magnetic properties of the Mn site substituted La{sub 0.67}Ca{sub 0.33}MnO{sub 3} with iso-valent diamagnetic and paramagnetic ions, we argue that local structural effects have a decisive role to play, compared to the local spin coupling effects, in the ferromagnetic-metallic ground

  17. Charge transfer-induced magnetic exchange bias and electron localization in (111)- and (001)-oriented LaNiO3/LaMnO3 superlattices

    Science.gov (United States)

    Wei, Haoming; Barzola-Quiquia, Jose Luis; Yang, Chang; Patzig, Christian; Höche, Thomas; Esquinazi, Pablo; Grundmann, Marius; Lorenz, Michael

    2017-03-01

    High-quality lattice-matched LaNiO3/LaMnO3 superlattices with monolayer terrace structure have been grown on both (111)- and (001)-oriented SrTiO3 substrates by pulsed laser deposition. In contrast to the previously reported experiments, a magnetic exchange bias is observed that reproducibly occurs in both (111)- and (001)-oriented superlattices with the thin single layers of 5 and 7 unit cells, respectively. The exchange bias is theoretically explained by charge transfer-induced magnetic moments at Ni atoms. Furthermore, magnetization data at low temperature suggest two magnetic phases in the superlattices, with Néel temperature around 10 K. Electrical transport measurements reveal a metal-insulator transition with strong localization of electrons in the superlattices with the thin LaNiO3 layers of 4 unit cells, in which the electrical transport is dominated by two-dimensional variable range hopping.

  18. A Randomized Trial to Evaluate the Effect of Local Endometrial Injury on the Clinical Pregnancy Rate of Frozen Embryo Transfer Cycles in Patients With Repeated Implantation Failure

    Directory of Open Access Journals (Sweden)

    Ensieh Shahrokh-Tehraninejad

    2016-12-01

    Full Text Available Objective: Repeated implantation failure (RIF is a condition in which the embryos implantation decreases in the endometrium. So, our aim was to evaluate the effect of local endometrial injury on embryo transfer results.Materials and methods: In this simple randomized clinical trial (RCT, a total of 120 patients were selected. The participants were less than 40 years old, and they are in their minimum two cycles of vitro fertilization (IVF. Patients were divided randomly into two groups of LEI (Local endometrial injury and a control group (n = 60 in each group. The first group had four small endometrial injuries from anterior, posterior, and lateral uterus walls which were obtained from people who were in 21th day of their previous IVF cycle. The second group was the patients who have not received any intervention.Results: The experimental and control patients were matched in the following factors. Regarding the clinical pregnancy rate, there was no significant difference noted between the experimental and the control group.Conclusion: Local endometrial injury in a preceding cycle does not increase the clinical pregnancy rate in the subsequent FET cycle of patients with repeated implantation failure.

  19. Effects of local application of platelet-rich plasma and guided tissue regeneration on stability of implants

    OpenAIRE

    Duka Miloš; Lazić Z.; Bubalo Marija; Tatić Z.; Đurđević D.; Matić Smiljana

    2010-01-01

    Osseointegration is a result of cellular migration, differentiation, bone formation, and bone remodelling on the surface of an implant. Each of these processes depends on platelets and blood coagulum. Platelet-rich plasma (PRP) is used to improve osseointegration and stability of implants. It is a blood fraction produced in a centrifuge which contains a high concentration of platelets. Platelets contain numerous growth factors which influence tissue reactions. The aim of the research is to te...

  20. Local Atomic and Electronic Structure with Magnetism of La0.7Ca0.3Mn1- x Cu x O3 ( x=0, 0.03, 0.06, 0.1)

    Science.gov (United States)

    Zhang, Hongguang; Shi, Jiangjian; Li, Yongtao; Liu, Hao; Dong, Xueguang; Chen, Kai; Hou, Qingteng; Huang, Yongchao; Ge, Xiaopeng; Zhao, Liang; Lu, Zixing; Li, Qi

    2012-10-01

    Local atomic and electronic structure with magnetic properties, especially Griffiths phase, of polycrystalline samples La0.7Ca0.3Mn1- x Cu x O3 ( x=0, 0.03, 0.06, 0.1) have been studied. The X-ray absorption spectra (XAS) of Cu 2 p core level prove that the valence state of Cu ions exhibits trivalent state when doping content x≤0.06 and divalent Cu2+ ions begin to show for x=0.1. For the valence states of Mn ions, the X-ray photoelectron spectroscopy data show that they are in mixed states of Mn3+ and Mn4+, and a shift to lower binding energy is observed, which is not attributed to the variation of valence states of Mn ions but the change of crystallographic surroundings, because there is no obvious change detected by X-ray absorption fine structure spectroscopy (XAFS). The Debye-Waller factor ( σ 2) of x=0.1 sample is only slightly larger compared to x=0, which may be the origin of enhancement of Griffiths phase observed in the inverse-susceptibility as a function of temperature ( H/ M˜ T). The H/ M˜ T curves of Cu doped samples indicate coexistence of FM, AFM and PM phase above Curie temperature T C , which may be related to the strong hybridization of O 2 p and Mn 3 d reflected by O 1 s XAS spectra.

  1. Accelerated Partial Breast Irradiation With Low-Dose-Rate Interstitial Implant Brachytherapy After Wide Local Excision: 12-Year Outcomes From a Prospective Trial

    Energy Technology Data Exchange (ETDEWEB)

    Hattangadi, Jona A. [Harvard Radiation Oncology Program, Boston, MA (United States); Powell, Simon N. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); MacDonald, Shannon M.; Mauceri, Thomas; Ancukiewicz, Marek [Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States); Freer, Phoebe [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Lawenda, Brian [21st Century Oncology, Las Vegas, NV (United States); Alm El-Din, Mohamed A. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Department of Clinical Oncology, Tanta University Hospital, Tanta (Egypt); Gadd, Michele A.; Smith, Barbara L. [Department of Surgical Oncology, Massachusetts General Hospital, Boston, MA (United States); Taghian, Alphonse G., E-mail: ataghian@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States)

    2012-07-01

    Purpose: To evaluate the long-term toxicity, cosmesis, and local control of accelerated partial breast irradiation with implant brachytherapy after wide local excision for Stage T1N0 breast cancer (BCa). Materials and Methods: Between 1997 and 2001, 50 patients with Stage T1N0M0 BCa were treated in a Phase I-II protocol using low-dose-rate accelerated partial breast irradiation with implant brachytherapy after wide local excision and lymph node surgery. The total dose was escalated in three groups: 50 Gy (n = 20), 55 Gy (n = 17), and 60 Gy (n = 13). Patient- and physician-assessed breast cosmesis, patient satisfaction, toxicity, mammographic abnormalities, repeat biopsies, and disease status were prospectively evaluated at each visit. Kendall's tau ({tau}{sub {beta}}) and logistic regression analyses were used to correlate outcomes with dose, implant volume, patient age, and systemic therapy. Results: The median follow-up period was 11.2 years (range, 4-14). The patient satisfaction rate was 67%, 67% reported good-excellent cosmesis, and 54% had moderate-severe fibrosis. Higher dose was correlated with worse cosmetic outcome ({tau}{sub {beta}} 0.6, p < .0001), lower patient satisfaction ({tau}{sub {beta}} 0.5, p < .001), and worse fibrosis ({tau}{sub {beta}} 0.4, p = .0024). Of the 50 patients, 35% had fat necrosis and 34% developed telangiectasias {>=}1 cm{sup 2}. Grade 3-4 late skin and subcutaneous toxicities were seen in 4 patients (9%) and 6 patients (13%), respectively, and both correlated with higher dose ({tau}{sub {beta}} 0.3-0.5, p {<=} .01). One patient had Grade 4 skin ulceration and fat necrosis requiring surgery. Mammographic abnormalities were seen in 32% of the patients, and 30% underwent repeat biopsy, of which 73% were benign. Six patients had ipsilateral breast recurrence: five elsewhere in the breast, and one at the implant site. One patient died of metastatic BCa after recurrence. The 12-year actuarial local control, recurrence

  2. Breast Implants

    Science.gov (United States)

    ... Medical Procedures Implants and Prosthetics Breast Implants Breast Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Breast implants are medical devices that are implanted under the ...

  3. Effects of magnetization on hole localization and MnO{sub 6} octahedra disorder in hole-doped lanthanum manganese perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Booth, C.H.; Brosha, E.L.; Kwei, G.H. [Los Alamos National Lab., NM (United States); Bridges, F. [Univ. of California, Santa Cruz, CA (United States). Physics Dept.; Neumeier, J.J. [Florida Atlanta Univ., Boca Raton, FL (United States). Physics Dept.

    1998-12-31

    The authors review the distortions of the MnO{sub 6} octahedra reduced by magnetization in hole-doped lanthanum manganese perovskites. The systems they consider include the colossal magnetoresistance (CMR) samples La{sub 1{minus}x}Ca{sub x}MnO{sub 3} (x = 0.21, 0.25, 0.30), La{sub 0.76}Ba{sub 0.33}MnO{sub 3}, and a poorer quality La{sub 0.76}Pb{sub 0.33}MnO{sub 3} sample. They also report preliminary work on three samples of oxygen-doped LaMnO{sub 3+{delta}} and a lanthanum-deficient La{sub 0.9}MnO{sub 3} sample. They find the same exponential relationship between the removal of the distortion and the sample magnetization in the Ba- and Pb-doped CMR samples as was found previously for the Ca doped samples. The MnO{sub 6} distortion in the oxygen-doped materials is found to slightly reduce below the magnetic transition, although much less so than in the CMR samples. Above T{sub C}, the antiferromagnetic LaMnO{sub 3.006} sample shows a softer temperature dependence of the Mn-O bond length distribution broadening. Surprisingly, even this sample shows deviations from thermal (Debye) behavior near T{sub N}, possibly due to FM coupling within MnO planes.

  4. Pre-edge features in X-ray absorption structure of Mn in GaMnN, GaMnAs and GeMn

    Energy Technology Data Exchange (ETDEWEB)

    Titov, A. [A.M. Prokhorov General Physics Institute, Russian Academy of Sciences, Vavilov str. 38, 119991 Moscow (Russian Federation) and ' Nanophysique et Semiconducteurs' , CEA-CNRS-Universite Joseph Fourier Grenoble, Laboratoire de Spectrometrie Physique, BP 87, 38402 St Martin d' Heres cedex (France)]. E-mail: titov@nsc.gpi.ru; Kulatov, E. [A.M. Prokhorov General Physics Institute, Russian Academy of Sciences, Vavilov str. 38, 119991 Moscow (Russian Federation); Uspenskii, Yu.A. [Lebedev Physical Institute, Russian Academy of Sciences, Leninskii prosp. 53, 119991 Moscow (Russian Federation); Biquard, X. [DRFMC-SP2M, CEA Grenoble-38054 Grenoble cedex 9 (France); Halley, D. [' Nanophysique et Semiconducteurs' , CEA-CNRS-Universite Joseph Fourier Grenoble, Laboratoire de Spectrometrie Physique, BP 87, 38402 St Martin d' Heres cedex (France); Kuroda, S. [' Nanophysique et Semiconducteurs' , CEA-CNRS-Universite Joseph Fourier Grenoble, Laboratoire de Spectrometrie Physique, BP 87, 38402 St Martin d' Heres cedex (France); Bellet-Amalric, E. [' Nanophysique et Semiconducteurs' , CEA-CNRS-Universite Joseph Fourier Grenoble, Laboratoire de Spectrometrie Physique, BP 87, 38402 St Martin d' Heres cedex (France); DRFMC-SP2M, CEA Grenoble-38054 Grenoble cedex 9 (France); Mariette, H. [' Nanophysique et Semiconducteurs' , CEA-CNRS-Universite Joseph Fourier Grenoble, Laboratoire de Spectrometrie Physique, BP 87, 38402 St Martin d' Heres cedex (France); Cibert, J. [Laboratoire Louis Neel, CNRS, BP 166, 38042 Grenoble cedex 9 (France)

    2006-05-15

    Ga{sub 1-x}Mn{sub x}N samples with a wide range of concentrations, from x=0.003 to 0.057, were grown by molecular beam epitaxy. X-ray diffraction and the simulation of the extended X-ray absorption fine structure (EXAFS) confirmed the wurtzite structure of the samples, without any secondary phase, and the location of Mn in the gallium sublattice of GaN. The valence state of Mn was studied using the X-ray absorption near-edge structure (XANES) at the K-edge of Mn. The shape of the measured XANES spectra does not depend on the Mn concentration: that implies the same valence state and local atomic structure around the Mn atom in all samples. A calculation of the electronic band structure of GaMnN, GaMnAs, GeMn and the XANES spectra of Mn in GaMnN was performed using the linearized augmented plane wave (LAPW) method. The calculated spectra fit well our experimental data. In particular, the comparison demonstrates that a peak in the pre-edge structure is directly related to the 3+ valence state of Mn. This was confirmed experimentally by measurements of the Mn K-edge in GaMn{sup 2+}As and ZnMn{sup 2+}Te. An application of proposed interpretation for GeMn is discussed.

  5. Risk factors and prediction of inflammatory complications and local secondary osteoporosis in the bone structure of jaws in dental intraosseous implantation in healthy subjects

    Directory of Open Access Journals (Sweden)

    Mashchenko I.S.

    2013-03-01

    Full Text Available As a result of complex clinical, immunologic and biochemical investigations of 48 patients peculiarities of development of inflammatory com¬plications, local osteoporosis and destruction of bone tissue after performed dental intraosseous implantantion were first revealed. It was shown that multiple surgical traumas of soft tissues of jaws and bone tissue of alveolar processes with putting 4 or more implants simultaneously may lead to reducing biocidity of mucosa of jaw tissues; this promotes lesion of oral cavity hygiene and development of inflammatory process in zone of periimplant. It is set that massive accumulation of soft coat and dental calculus in the area of implant, superconstruction and marked deficit of sIgA production of oral mucosa promote development of periimplant mucositis in remote post-operative period. A sharp production of secretory ІL -1β is a risk factor in formation of general-destructive process in a periimplant zone, development of dental periimplant.

  6. The effect of MC and MN stabilizer additions on the creep rupture properties of helium implanted Fe-25% Ni-15% Cr austenitic alloy

    Science.gov (United States)

    Yamamoto, Norikazu; Nagakawa, Johsei; Shiraishi, Haruki

    1995-10-01

    Helium embrittlement resistance of Fe-25% Ni-15% Cr austenitic alloys with various MX (M = V, Ti, Nb, Zr; X = C, N) stabilizers was compared through post helium implantation creep testing at 923 K. While significant deterioration by helium in terms of creep rupture time and elongation occurred for all materials investigated, the suppression of the deterioration, especially in rupture time, was discerned for the materials in which semi-coherent MC (M = Ti, Ti + Nb, V + Ti) particles were distributed at high density. The material which contains the incoherent M 23C 6 as predominant precipitates seems to be less degraded by helium than those containing the MXs (M = Zr, V; X = C, N), if compared at the same number density of precipitates. Therefore, it is suggested that the high density dispersion of incoherent M 23C 6 as well as semi-coherent Ti containing MC particles would be beneficial in reducing the detrimental helium influences on mechanical properties.

  7. A novel porcine model of implant associated osteomyelitis: a comprehensive analysis of local, regional and systemic response

    DEFF Research Database (Denmark)

    Jensen, Louise Kruse; Koch, Janne; Dich-Jorgensen, Kirstine;

    2017-01-01

    Pigs are favorable experimental animals for infectious diseases in humans. However, implant associated osteomyelitis (IAO) models in pigs have only been evaluated using high-inoculum infection (>108 CFU) models in 1975 and 1993. Therefore, the aim of this paper was to present a new low inoculum...

  8. Peri-implant hastalıklar

    OpenAIRE

    Dilsiz, Alparslan; Zihni, Meltem; Yavuz, M Selim

    2011-01-01

    The treatment of partially or totally edentulous subjects with oral implants is a common procedure. Biological complications are occur around implants which are peri-implant mucositis and periimplantitis. Peri-implant mucositis is pathological condition which is normally localized in the soft tissues surrounding an oral implant. Peri-implantitis surrounding oral implants is an inflammatory process affecting the soft and hard tissues resulting in rapid loss of supporting bone associated with b...

  9. Peri-implant hastalıklar

    OpenAIRE

    Dilsiz, Alparslan; Zihni, Meltem; YAVUZ, M. Selim

    2011-01-01

    The treatment of partially or totally edentulous subjects with oral implants is a common procedure. Biological complications are occur around implants which are peri-implant mucositis and periimplantitis. Peri-implant mucositis is pathological condition which is normally localized in the soft tissues surrounding an oral implant. Peri-implantitis surrounding oral implants is an inflammatory process affecting the soft and hard tissues resulting in rapid loss of supporting bone associated with b...

  10. Pre-edge features in X-ray absorption structure of Mn in GaMnN, GaMnAs and GeMn

    Science.gov (United States)

    Titov, A.; Kulatov, E.; Uspenskii, Yu. A.; Biquard, X.; Halley, D.; Kuroda, S.; Bellet-Amalric, E.; Mariette, H.; Cibert, J.

    2006-05-01

    Ga1-xMnxN samples with a wide range of concentrations, from x=0.003 to 0.057, were grown by molecular beam epitaxy. X-ray diffraction and the simulation of the extended X-ray absorption fine structure (EXAFS) confirmed the wurtzite structure of the samples, without any secondary phase, and the location of Mn in the gallium sublattice of GaN. The valence state of Mn was studied using the X-ray absorption near-edge structure (XANES) at the K-edge of Mn. The shape of the measured XANES spectra does not depend on the Mn concentration: that implies the same valence state and local atomic structure around the Mn atom in all samples. A calculation of the electronic band structure of GaMnN, GaMnAs, GeMn and the XANES spectra of Mn in GaMnN was performed using the linearized augmented plane wave (LAPW) method. The calculated spectra fit well our experimental data. In particular, the comparison demonstrates that a peak in the pre-edge structure is directly related to the 3+ valence state of Mn. This was confirmed experimentally by measurements of the Mn K-edge in GaMnAs and ZnMnTe. An application of proposed interpretation for GeMn is discussed.

  11. Local electrogram delay recorded from left ventricular lead at implant predicts response to cardiac resynchronization therapy: Retrospective study with 1 year follow up

    Directory of Open Access Journals (Sweden)

    Polasek Rostislav

    2012-05-01

    Full Text Available Abstract Background Considerable proportion of patients does not respond to the cardiac resynchronization therapy (CRT. This study investigated clinical relevance of left ventricular electrode local electrogram delay from the beginning of QRS (QLV. We hypothesized that longer QLV indicating more optimal lead placement in the late activated regions is associated with the higher probability of positive CRT response. Methods We conducted a retrospective, single–centre analysis of 161 consecutive patients with heart failure and LBBB or nonspecific intraventricular conduction delay (IVCD treated with CRT. We routinely intend to implant the LV lead in a region with long QLV. Clinical response to CRT, left ventricular (LV reverse remodelling (i.e. decrease in LV end-systolic diameter - LVESD ≥10% and reduction in plasma level of NT-proBNP >30% at 12-month post-implant were the study endpoints. We analyzed association between pre-implant variables and the study endpoints. Results Clinical CRT response rate reached 58%, 84% and 92% in the lowest (≤105 ms, middle (106-130 ms and the highest (>130 ms QLV tertile (p  Conclusion LV lead position assessed by duration of the QLV interval was found the strongest independent predictor of beneficial clinical response to CRT.

  12. 载二膦酸盐种植材料的研究进展%Developments in Research of Local Bisphosphonate Delivery System of Implant Denture

    Institute of Scientific and Technical Information of China (English)

    臧程程; 翟俊江; 孟艳华

    2011-01-01

    种植义齿作为一种先进的口腔修复治疗手段,现在已广泛地为牙齿缺失患者所接受.而种植体周骨量不足仍然成为其应用受到限制的重要原因之一.二膦酸盐(BPs) 类药物是当今临床上广泛使用的破骨细胞性骨吸收抑制剂,可以抑制骨吸收,增加骨密度.由于BPs全身应用的种种缺陷,其在种植体上的局部应用近来成为研究热点.磷酸钙陶瓷、聚乳酸、纤维蛋白膜和胶原膜都已作为BPs载体被报道.本文将对BPs的骨调节机制和局部释药系统的研究进展作一综述.%Dental implant is an advanced prosthodontic treatment widely accepted by patients with missing tooth.However, peri-implant bone loss is still an important reason which limits wider application of the implants to a certain extent. Bisphosphonates is an osteoclastic bone resorption inhibitor that is widely used in clinical practice with the function of inhibiting bone resorption and increasing bone density. As the defect of systemic BPs treatment, local application of BPs in implant has become a research hotspot recently. Calcium phosphate ceramics, polylactic acid.fibrinogen film and collagen membrane have been reported as BPs carriers. This article summarizes the researchs on the mechanism of bone regulation and lacal delivering system of BPs.

  13. Effects of localized holes on charge transport, local structure and spin dynamics in the metallic state of CMR La{sub 1{minus}x}Ca{sub x}MnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Heffner, R.H.; Hundley, M.F. [Los Alamos National Lab., NM (United States); Booth, C.H. [Los Alamos National Lab., NM (United States)]|[Univ. of California, Irvine, CA (United States). Dept. of Physics

    1998-03-01

    The authors review resistivity, x-ray-absorption fine-structure (XAFS) and muon spin relaxation ({mu}SR) data which provide clear evidence for localized holes causing polaron distortion and unusual spin dynamics below {Tc} in ``colossal magnetoresistive`` (CMR) La{sub 1{minus}x}Ca{sub x}MnO{sub 3}. Resistivity measurements for x = 0.33 under an applied field H have shown that ln[{rho}(H,T)] {infinity}-M, where M is the magnetization. The XAFS data show a similar functional dependence for the polaron distortions on M The data from these two measurements are interpreted in terms of some fraction of the available holes x remaining localized and some increasing fraction becoming delocalized with increasing M Finally, this polaron-induced spatial inhomogeneity yields anomalously slow, spatially inhomogeneous spin dynamics below {Tc}, as shown in the {mu}SR data. These experiments individually probe the charge, lattice and spin degrees of freedom in this CMR system and suggest that the polarons retain some identity even at temperatures significantly below {Tc}.

  14. Penile Implants

    Science.gov (United States)

    ... the discussion with your doctor. Types of penile implants There are two main types of penile implants: ... might help reduce the risk of infection. Comparing implant types When choosing which type of penile implant ...

  15. Histological Evaluation of the Local Soft Tissue Reaction After Implanting Resorbable and Non-resorbable Monofilament Fibers.

    Science.gov (United States)

    Żywicka, Bogusława; Szymonowicz, Maria; Bryła, Danuta; Rybak, Zbigniew

    2016-01-01

    The development of technologies and scientific disciplines connected with medical implantation devices is dynamically affecting modern treatments by contemporary medicine and veterinary medicine; it also entails a need to monitor their impact on living organisms. The aim of the study was to conduct a comparative histological evaluation of the response of soft tissues after implanting monofilament fibers from resorbable glyconate and from non-resorbable polypropylene (PP) and polyamide (PA) in rats. Non-resorbable polyamide-based fibers were applied to skin anastomoses in rats. Macroscopic and histological evaluations were performed on the 7th, 14th and 30th days. Non-resorbable polypropylene fibers and resorbable glyconate fibers (composed of 72% glycolide, 14% trimethylene carbonate and 4% caprolactone) were implanted in muscle tissue for periods of 7, 14, 30 and 90 days. A semi-quantitative and qualitative histological evaluation found different dynamics and degrees of intensification of cell and tissue response around the resorbable and non-resorbable fibers being tested. The resorption process of the glyconate threads caused a prolonged inflammatory cellular response compared to the non-resorbable threads; it passed, however, without the participation of giant cells. Around the non-resorbable threads the observed cellular response was less intensified, with the formation of single polymorphonuclear macrophages around the PP threads, along with a stronger degree of fibrosis and the presence of fatty infiltrate. During the early period, moderately intensified inflammatory cell response with the presence of single giant cells was observed around the non-degradable PA and PP fibers. In the late period, a band of fibrous connective tissue was present around the PP threads. Glyconate fibers underwent fragmentation and the process of resorption, which was associated with a weakly intensified inflammatory process lasting up to 90 days after implantation.

  16. Local strains, calorimetry, and magnetoresistance in adaptive martensite transition in multiple nanostrips of Ni39+xMn50Sn11−x(x ≤ 2 alloys

    Directory of Open Access Journals (Sweden)

    A A Prasanna and Shanker Ram

    2013-01-01

    Full Text Available Ni39+xMn50Sn11−x (x = 0.5, 1.0, 1.5 and 2 alloys comprise multiple martensite nanostrips of nanocrystallites when cast in small discs, for example, ~15 mm diameter and 8 mm width. A single martensite phase with a L10 tetragonal crystal structure at room temperature can be formed at a critical Sn content of 9.0 at.% (x = 2, whereas an austenite cubic L21 phase turns up at smaller x ≤ 1.5. The decrease in the Sn content from x = 2 to 0.5 also results in a gradual increase in the crystallite size from 11 to 17 nm. Scanning electron microscopy images reveal arrays of regularly displaced multiple martensite strips (x ≥ 1.5 with an average thickness of 20 nm. As forced oscillators, these strips carry over the local strains, magnetic dipoles, and thermions simultaneously in a martensite–austenite (or reverse phase transition. A net residual enthalpy change ΔHM↔A = −0.12 J g−1 arises in the process that lacks reversibility between the cooling and heating cycles. A large magnetoresistance of (–26% at 10 T is observed together with a large entropy change of 11.8 mJ g−1 K−1, nearly twice the value ever reported in such alloys, in the isothermal magnetization at 311 K. The ΔHM↔A irreversibility accounts for a thermal hysteresis in the electrical resistivity. Strain induced in the martensite strips leads them to have a higher electrical resistivity than that of the higher-temperature austenite phase. A model considering time-dependent enthalpy relaxation explains the irreversibility features.

  17. Crystal field energy levels, spin-Hamiltonian parameters and local structures for the Cr3+ and Mn4+ centers in La3Ga5SiO14 crystals

    Science.gov (United States)

    Mei, Yang; Chen, Bo-Wei; Zheng, Wen-Chen; Li, Bang-Xing

    2017-02-01

    The crystal field energy levels (obtained from optical spectra) together with the spin-Hamiltonian parameters g//, g⊥ and D (obtained from EPR spectra) for 3d3 ions Cr3+ and Mn4+ at the trigonal octahedral Ga3+ sites in La3Ga5SiO14 crystals are computed from the complete diagonalization (of energy matrix) method based on the two-spin-orbit-parameter model. The model takes into account the contributions due to the spin-orbit parameter of central dn ion (in the traditional crystal field theory) and that of ligand ions via covalence effect. The calculated results are in rational accord with the experimental values. The calculations also imply that the covalence of (MnO6)8- center in La3Ga5SiO14 crystals is stronger than that of (CrO6)9- center, and the impurity-induced local lattice relaxation for (MnO6)8- center is larger than that for (CrO6)9- cluster because of the larger size and charge mismatch for Mn4+ replacing Ga3+ in La3Ga5SiO14 crystals.

  18. Localization of dislocation-related luminescence centers in self-ion implanted silicon and effect of additional boron ion doping

    Energy Technology Data Exchange (ETDEWEB)

    Tetelbaum, D.I.; Mikhaylov, A.N.; Belov, A.I.; Korolev, D.S.; Shushunov, A.N.; Bobrov, A.I.; Pavlov, D.A. [Lobachevsky State University of Nizhni Novgorod (Russian Federation); Shek, E.I.; Sobolev, N.A. [Ioffe Physical Technical Institute, St. Petersburg (Russian Federation)

    2015-01-01

    The depth distribution of light-emitting centers of the D1 dislocation-related photoluminescence line (∝ 1.5 μm) in silicon implanted with Si{sup +} ions and annealed at 1100 C in the oxidizing chlorine-containing atmosphere has been investigated by means of the layer-by-layer chemical etching. It is established with the application of cross-sectional transmission electron microscopy that the main contribution to the D1 line is made by the centers located at the depths of up to ∝ 150 nm, i.e. in the region of Si{sup +} ion ranges, whereas the dislocations produced by Si{sup +} implantation and annealing at 1100 C penetrate to the depth of ∝ 1000 nm. Additional boron ion doping with subsequent annealing at 800 C in N{sub 2} atmosphere improves the emission in comparison with the undoped but annealed reference sample, however the additional annealing at 800 C per se results in the photoluminescence weakening. The dependence of the D1 line intensity on boron ion dose is found to be nonmonotonous. The interpretation of the obtained results is given in relation to the key role of selfinterstitials and boron impurity in the formation of radiative and nonradiative centers. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  19. Development and characterization of local anti-inflammatory implantation for the controlled release of the hexane extract of the flower-heads of Euryops pectinatus L. (Cass.).

    Science.gov (United States)

    Nesseem, D I; Michel, C G

    2011-04-01

    A hexane extract of the flower-heads of Euryops pectinatus L. (Cass.) was formulated into local anti-inflammatory implantation patches with controlled release. Cross-linked sodium hyaluronate patches (F1-F3) and chitosan patches (F4-F6) were prepared by a casting/solvent evaporation technique. Morphological and mechanical characterizations including the components ratio, surfactant and the loaded amount of the hexane extract (50, 100, and 200 mg/kg b.wt.) were investigated. Release studies were performed during 24 h using a diffusion cell. Films with optimum in vitro release rate have been investigated for testing the anti-inflammatory activity and the sustaining effect of the formulations. The sustained anti-inflammatory effect of the hexane extract of E. pectinatus flower-heads from the selected films was studied by inducing paw edema in rats with 1% (w/v) carrageenan solution. The results indicated the compatibility of hexane extract with both sodium hyaluronate and chitosan patches forming yellowish transparent films. Based on variations in drug release profiles throughout the 24-h among the formulations (F1-F6) studies, F3 and F6 were selected for further investigation. When the films were applied 1 h before the subplantar injection of carrageenan in the hind paw of male Albino rats, formulation (F3) provided its maximum inhibition of paw edema in rats (91.3%) 4 h after edema induction whereas, formulation (F6) showed less inhibition after 4 h (70.6%). The previous two formulations (F3 and F6) produced potent results (95.3 and 89.5%, respectively) after 24 h when compared with a local market preparation containing 25% β-sitosterol used as positive control. Histophathological investigation was conducted for 1, 4, and 12 weeks to study the tissue response for the two formulations (F3 and F6) at the implantation site. Chemical investigation of the hexane extract was achieved for both unsaponifiable matter (USM) and fatty acid methyl esters (FAME) using gas

  20. Use of brachytherapy with permanent implants of iodine-125 in localized prostate cancer; La curietherapie par implants permanents d'I-125 dans le cancer localise de la prostate

    Energy Technology Data Exchange (ETDEWEB)

    Bladou, F.; Serment, G. [Hopital Salvador, Service d' Urologie, 13 - Marseille (France); Salem, N.; Simonian, M. [Hopital Salvador, Dept. de Radiotherapie, 13 - Marseille (France); Rosello, R.; Ternier, F. [Institut Paoli-Calmettes, Dept. de Radiologie, 13 - Marseille (France)

    2002-07-01

    Approximately 15,000 cases of early stage prostate cancer T1 and T2 are diagnosed every year in France by testing for PSA and performing prostatic biopsies. The treatment of these localized forms is based in most cases on radical prostatectomy or nn external beam radiotherapy. Although the ontological results obtained by these two therapeutic methods are satisfactory and equivalent in the long term, the side effects can be important. For a number of years, trans-perineal brachytherapy using permanent implants of iodine -125 or palladium-103 has proved itself as an alternative therapy with equivalent medium to long-term results. The low urinary, digestive and sexual side effects of prostate brachytherapy are important reasons for the enthusiasm among patients and the medical community for this therapy and the growing number of applications and centres which practice it. In September 1998 we started the prostate brachytherapy programmes- in Marseilles with close collaboration between the department of urology of the Hopital Salvator, and the departments of radiotherapy, medical imaging and medical physics of the Institut Paoli-Calmettes. To date, around 250 patients with localized adenocarcinoma of the prostate have benefited from this alternative therapy in our centre. Preliminary results, with a 3 year-follow-up, are comparable to results published in the literature by pioneer teams. (authors)

  1. Radiography of the mandible prior to endosseous implant treatment. Localization of the mandibular canal and assessment of trabecular bone

    Energy Technology Data Exchange (ETDEWEB)

    Lindh, C.

    1996-03-01

    Mandibular autopsy specimens were examined with different radiographic techniques in order to evaluate the visibility of the mandibular canal and the measurement accuracy of distances related to the mandibular canal. Hypocycloidal, spiral and computed tomography (CT) were superior to periapical and panoramic radiography in visualizing the mandibular canal. The tomographic techniques were more accurate when measurements of distances related to the mandibular canal were performed. No difference in measurement accuracy was found between the tomographic techniques. Concerning visibility of the mandibular canal, interobserver agreement was lowest for periapical radiography and highest for CT. Intraobserver agreement was moderate or good for all techniques. A high interobserver variation was found for measurability of distances related to the mandibular canal. The trabecular bone tissue in mandibular autopsy specimens was studied concerning different characteristics. A classification system to be used prior to implant treatment, based on the trabecular pattern in periapical radiographs, was proposed. 74 refs.

  2. Non-local spin injection effects in coplanar La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8}/ La{sub 0.7}Sr{sub 0.3}MnO{sub 3} tri-layer

    Energy Technology Data Exchange (ETDEWEB)

    Joseph, D. Paul [Department of Physics, National Institute of Technology, Warangal, Telangana-506 004 (India); Lin, J. G., E-mail: jglin@ntu.edu.tw [Center for Condensed Matter Sciences, National Taiwan University, Taipei 10617, Taiwan (China)

    2015-06-24

    Non-local electrical properties of pulsed laser deposited La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8}/La{sub 0.7}Sr{sub 0.3}MnO{sub 3} (L-B-L) coplanar tri-layer is investigated under different wiring configurations. Long range super-current of Bi-2212 penetrating into LSMO is dependent on geometry of spin injection. From qualitative analysis of structural, magnetic and electrical data, long range super-current is suggested to pass through domain walls and/or grain boundaries of LSMO.

  3. Dental Implants.

    Science.gov (United States)

    Griggs, Jason A

    2017-10-01

    Systematic reviews of literature over the period between 2008 and 2017 are discussed regarding clinical evidence for the factors affecting survival and failure of dental implants. The factors addressed include publication bias, tooth location, insertion torque, collar design, implant-abutment connection design, implant length, implant width, bone augmentation, platform switching, surface roughness, implant coatings, and the use of ceramic materials in the implant body and abutment. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Paramagnetism in ion-implanted oxides

    CERN Document Server

    Mølholt, Torben Esmann; Gíslason, Hafliði Pétur; Ólafsson, Sveinn

    This thesis describes the investigation on para-magnetism in dilute ion-implanted single-crystal oxide samples studied by on- and off-line $^{57}$Fe emission Mössbauer spectroscopy. The ion-implantation of the radioactive isotopes ( $^{57}$Mn and $^{57}$Co) was performed at the ISOLDE facility at CERN in Geneva, Switzerland. The off-line measurements were performed at Aarhus University, Denmark. Mössbauer spectroscopy is a unique method, giving simultaneously local information on valence/spin state of the $^{57}$Fe probe atoms, site symmetry and magnetic properties on an atomic scale. The utilisation of emission Mössbauer spectroscopy opens up many new possibilities compared with traditional transmission Mössbauer spectroscopy. Among them is the possibility of working with a low concentration below 10$^{-4}$ –10$^{-3}$ at.%, where the implanted Mössbauer $^{57}$Fe probes are truly dilute impurities exclusively interacting with their nearest neighbours and therefore the possibility of crea...

  5. Prostatic fiducial markers implantation by transrectal ultrasound for adaptive image guided radiotherapy in localized cancer: 7-years experience

    Directory of Open Access Journals (Sweden)

    Vito Lacetera

    2014-12-01

    Full Text Available Objective: we present our 7-years’ experience with fiducial gold markers inserted before Image-Guided Radiotherapy (IGRT focusing on our echo-guided technique reporting early and late complications. Material and methods: 78 prostate cancer (PCA patients who underwent fiducial markers placement for adaptive IGRT (period 2007-2014 were selected. Mean patient age was 75 years (range 60-81, mean PSA 7.8 ng/ml (range 3.1-10, clinical stage < T3, mean Gleason Score 6.4 (range 6-7. We recorded early and late complications. Maximum distance between the Clinical Target Volume (CTV and Planning Target Volume (PTV was assessed for each direction and the mean PTV reduction was estimated. Results: we describe in details our echo-guided technique of intraprostatic gold fiducial markers insertion prior to adaptative IGRT. We report rare early toxicity (5-7% grade 1-2, a mean PTV reduction of 37% and a very low late toxicity (only 3.4% bladder G3 and 8% rectal G2 side effects. Conclusion: Our technique of fiducial gold markers implantation for adaptative IGRT is safe and well-tolerated and it resulted helpful to reduce CTV-PTV margin in all cases; the effects on clinical practice seem significant in terms of late toxicity but further investigations are needed with longer follow-up.

  6. In vivo transfer of intracellular labels from locally implanted bone marrow stromal cells to resident tissue macrophages.

    Directory of Open Access Journals (Sweden)

    Edyta Pawelczyk

    Full Text Available Intracellular labels such as dextran coated superparamagnetic iron oxide nanoparticles (SPION, bromodeoxyuridine (BrdU or green fluorescent protein (GFP are frequently used to study the fate of transplanted cells by in vivo magnetic resonance imaging or fluorescent microscopy. Bystander uptake of labeled cells by resident tissue macrophages (TM can confound the interpretation of the presence of intracellular labels especially during direct implantation of cells, which can result in more than 70% cell death. In this study we determined the percentages of TM that took up SPION, BrdU or GFP from labeled bone marrow stromal cells (BMSCs that were placed into areas of angiogenesis and inflammation in a mouse model known as Matrigel plaque perfusion assay. Cells recovered from digested plaques at various time points were analyzed by fluorescence microscopy and flow cytometry. The analysis of harvested plaques revealed 5% of BrdU(+, 5-10% of GFP(+ and 5-15% of dextran(+ macrophages. The transfer of the label was not dependent on cell dose or viability. Collectively, this study suggests that care should be taken to validate donor origin of cells using an independent marker by histology and to assess transplanted cells for TM markers prior to drawing conclusions about the in vivo behavior of transplanted cells.

  7. Application of Local Adsorbant From Southeast Sulawesi Clay Immobilized Saccharomyces Cerevisiae Bread’s Yeast Biomass for Adsorption Of Mn(Ii) Metal Ion

    Science.gov (United States)

    R, Halimahtussaddiyah; Mashuni; Budiarni

    2017-05-01

    Southeast Sulawesi has a great stock of clay. It is probably to use as a source of adsorbent. The adsorbent capacity of clay can be largered with teratment using bread’s yeast as biomass. At this research, study of analysis adsorption of Mn(II) metal ion on clay immobilized Saccharomyces cerevisiae bread’s yeast biomass adsorbent has been conducted. The aims of this research were to determine the effects of contact time, pH and concentration of Mn(II) metal ion and to determine the adsorption capacity of clay immobilized S. cerevisiae biomass for adsorbtion of Mn(II) metal ion. Activated clay was synthesized by reaction of clay with KMnO4, H2SO4 and HCl. S. cerevisiae biomass was result by bread’s yeast mashed. Immobilization of S. cerevisiae biomass into clay was done by mixing of ratio of S. cerevisiae bread’s yeast biomass and clay equal to 1:3 (mass of biomassa : mass of clay). The adsorption capacity was determined by using Freundlich and Langmuir adsorption isoterms. The results of FTIR spectrums showed that the functional groups of clay immobilized S. cerevisiae biomass were Si-OH (wave number 1643 cm-1), Si-O-Si (wave number 1033 cm-1), N-H (wave number 2337 cm-1), O-H (wave number 3441cm-1), and C-H (wave number 2931 cm-1). The result of adsorption capacity from Mn(II) metal ion of contact time optimum 120 minutes, pH optimun at 7 and concentration optimum 50 mg/L were 1,816 mg/g; 0,509 mg/g and 2,624mg/g respectively. The adsorption capacity of Mn(II) metal ion with ratio 1:3 (biomass : clay) was 0,1045 mg/g. Type of isothermal adsorption followed the Freunlich adsorption.

  8. Local hemodynamic changes caused by main branch stent implantation and subsequent virtual side branch balloon angioplasty in a representative coronary bifurcation.

    Science.gov (United States)

    Williams, Andrew R; Koo, Bon-Kwon; Gundert, Timothy J; Fitzgerald, Peter J; LaDisa, John F

    2010-08-01

    Abnormal blood flow patterns promoting inflammation, cellular proliferation, and thrombosis may be established by local changes in vessel geometry after stent implantation in bifurcation lesions. Our objective was to quantify altered hemodynamics due to main vessel (MV) stenting and subsequent virtual side branch (SB) angioplasty in a coronary bifurcation by using computational fluid dynamics (CFD) analysis. CFD models were generated from representative vascular dimensions and intravascular ultrasound images. Time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and fractional flow reserve (FFR) were quantified. None of the luminal surface was exposed to low TAWSS (stenting introduced eccentric areas of low TAWSS along the lateral wall of the MV. Virtual SB angioplasty resulted in a more concentric region of low TAWSS in the MV distal to the carina and along the lateral wall of the SB. The luminal surface exposed to low TAWSS was similar before and after virtual SB angioplasty (rest: 43% vs. 41%; hyperemia: 18% vs. 21%) and primarily due to stent-induced flow alterations. Sites of elevated OSI (>0.1) were minimal but more impacted by general vessel geometry established after MV stenting. FFR measured at a jailed SB was within the normal range despite angiographic stenosis of 54%. These findings indicate that the most commonly used percutaneous interventional strategy for a bifurcation lesion causes abnormal local hemodynamic conditions. These results may partially explain the high clinical event rates in bifurcation lesions.

  9. An insight into the local O{sub h} {yields}T{sub d} instability in BaF{sub 2}:Mn{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Fernandez, P; Aramburu, J A; Barriuso, M T; Moreno, M, E-mail: morenom@unican.e

    2010-11-01

    While most complexes in fluorite-type lattices (CaF{sub 2}, SrF{sub 2}, CdF{sub 2}) containing Mn{sup 2+} impurities remain cubic at all temperatures, electron paramagnetic resonance (EPR) measurements have shown that the one in BaF{sub 2} is tetrahedral below 50K. This surprising behaviour is intrinsic to the centre and not associated to any close defect or pure lattice phase-transition. Through the use of density functional (DFT) calculations we show that the distortion is linked to the unexpected low force constant along the tetrahedral distortion mode with a{sub 2u} symmetry in these complexes and the large metal-ligand distance existing in BaF{sub 2}:Mn{sup 2+}. Ultimately, these facts reflect that, for substitutional impurities in fluorite-type crystals, the ligand-ligand interaction is dominant over the metal-ligand one.

  10. local

    Directory of Open Access Journals (Sweden)

    Abílio Amiguinho

    2005-01-01

    Full Text Available The process of socio-educational territorialisation in rural contexts is the topic of this text. The theme corresponds to a challenge to address it having as main axis of discussion either the problem of social exclusion or that of local development. The reasons to locate the discussion in this last field of analysis are discussed in the first part of the text. Theoretical and political reasons are there articulated because the question is about projects whose intentions and practices call for the political both in the theoretical debate and in the choices that anticipate intervention. From research conducted for several years, I use contributions that aim at discuss and enlighten how school can be a potential locus of local development. Its identification and recognition as local institution (either because of those that work and live in it or because of those that act in the surrounding context are crucial steps to progressively constitute school as a partner for development. The promotion of the local values and roots, the reconstruction of socio-personal and local identities, the production of sociabilities and the equation and solution of shared problems were the dimensions of a socio-educative intervention, markedly globalising. This scenario, as it is argued, was also, intentionally, one of transformation and of deliberate change of school and of the administration of the educative territoires.

  11. Feasibility of MR Imaging/MR Spectroscopy-Planned Focal Partial Salvage Permanent Prostate Implant (PPI) for Localized Recurrence After Initial PPI for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Charles C., E-mail: hsucc@radonc.ucsf.edu [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Hsu, Howard [Department of Radiation Oncology, New York University, New York, New York (United States); Pickett, Barby [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Crehange, Gilles [Department of Radiation Oncology, Dijon University, Dijon (France); Hsu, I-Chow Joe; Dea, Ryan [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Weinberg, Vivian [Biostatistics and Computational Biology Core, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Gottschalk, Alexander R. [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Kurhanewicz, John [Department of Radiology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Shinohara, Katsuto [Department of Urology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States); Roach, Mack [Department of Radiation Oncology, University of California, San Francisco Helen Diller Family Comprehensive Cancer Center, San Francisco, California (United States)

    2013-02-01

    Purpose: To assess the feasibility of magnetic resonance imaging (MRI)-planned partial salvage permanent prostate implant (psPPI) among patients with biopsy-proven local recurrence after initial PPI without evidence of distant disease. Methods and Materials: From 2003-2009, 15 patients underwent MRI/magnetic resonance spectroscopy (MRS) planning for salvage brachytherapy (psPPI, I-125 [n=14; 144 Gy]; Pd-103 [n=1; 125 Gy]) without hormone therapy. Full dose was prescribed to areas of recurrence and underdosage, without entire prostate implantation. Limiting urethral and rectal toxicity was prioritized. Follow-up was from salvage date to prostate-specific antigen (PSA) concentration failure (Phoenix criteria = nadir + 2.0; ASTRO = 3 consecutive rises), recurrence, distant metastases, or last follow-up PSA level. Progression-free survival (PFS) was defined as no PSA failure or biopsy-proven recurrence without all-cause mortality. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Results: At salvage, median age was 68 years, and PSA concentration was 3.5 ng/mL (range, 0.9-5.6 ng/mL). Abnormal MRI/MRS findings were evident in 40% of patients. Biopsy-proven recurrences consisted of a single focus (80%) or 2 foci (20%). At recurrence, Gleason score was 6 (67%) or {>=}7 (27%). Median interval between initial and salvage implantation was 69 months (range, 28-132 months). psPPI planning characteristics limited doses to the rectum (mean V100 = 0.5% [0.07 cc]) and urethra (V100 = 12% [0.3 cc]). At median follow-up (23.3 months; range, 8-88 months), treatment failure (n=2) resulted only in localized recurrence; both patients underwent second psPPI with follow-up PSA tests at 12 and 26 months, resulting in 0.6 and 0.7 ng/mL, respectively. American Society for Radiation Oncology PFS rates at 1, 2, and 3 years were 86.7%, 78.4%, and 62.7%, respectively, with 5 patients for whom treatment failed (n=3 with negative transrectal ultrasound

  12. Quantifying Local and Cooperative Components in the Ferroelectric Distortion of BaTiO3: Learning from the Off-Center Motion in the MnCl65– Complex Formed in KCl:Mn+

    DEFF Research Database (Denmark)

    García Lastra, Juan Maria; García-Fernández, P.; Calle-Vallejo, F.

    2014-01-01

    The delicate balance between cooperative and local contributions in the ferroelectric distortions of BaTiO3 is explored by means of ab initio calculations. As a salient feature, it is found that a single Ti4+ ion in BaTiO3 is not allowed to move off-center at ambient pressure, while this is no lo...... at ambient pressure. The present results thus stress the deep link between the structural phase transitions of ferroelectric materials and local phase transitions displayed by transition-metal impurities in insulators....

  13. Effect of Mn and MnS on corrosion properties of domestic pipeline steels and welds

    Institute of Scientific and Technical Information of China (English)

    李云涛; 杜则裕; 陶勇寅; 李建军

    2004-01-01

    Base metals of domestic pipeline steels were used to study the effect of Mn on corrosion properties of SSCC(Sulfide Stress Corrosion Cracking), and welds were carried out to study the effect of MnS on corrosion properties of HIC (Hydrogen Induced Cracking) both in solutions with wet hydrogen sulfide(H2S). They were respectively conducted by referring to the standards of SSCC and HIC. Testing results revealed that with the increase of content Mn, the resistance of SSCC will be decreased, from the point of metallurgic view, and it is Mn element not C element to lead to the testing results of SSCC. Meanwhile, even under the condition without inclusions MnS, HIC in welds still occurred. That is to say, MnS is not necessary for HIC, the presence of local banded structures in which Mn and P are inclined to aggregate cause to the phenomena of HIC.

  14. Charge, orbital and spin ordering phenomena in the mixed valence manganite (NaMn3+3)(Mn3+2Mn4+2)O12

    Science.gov (United States)

    Prodi, A.; Gilioli, E.; Gauzzi, A.; Licci, F.; Marezio, M.; Bolzoni, F.; Huang, Q.; Santoro, A.; Lynn, J. W.

    2004-01-01

    Mixed-valence manganites with the ABO3 perovskite structure display a variety of magnetic and structural transitions, dramatic changes of electrical conductivity and magnetoresistance effects. The physical properties vary with the relative concentration of Mn3+ and Mn4+ in the octahedral corner-sharing network, and the proportion of these two cations is usually changed by doping the trivalent large A cation (for example, La3+) with divalent cations. As the dopant and the original cation have, in general, different sizes, and as they are distributed randomly in the structure, such systems are characterized by local distortions that make it difficult to obtain direct information about their crystallographic and physical properties. On the other hand, the double oxides of formula AA'3Mn4O12 contain a perovskite-like network of oxygen octahedra centred on the Mn cations, coupled with an ordered arrangement of the A and A' cations, whose valences control the proportion of Mn3+ and Mn4+ in the structure. The compound investigated in this work, (NaMn3+3)(Mn3+2Mn4+2)O12, contains an equal number of Mn3+ and Mn4+ in the octahedral sites. We show that the absence of disorder enables the unambiguous determination of symmetry, the direct observation of full, or nearly full, charge ordering of Mn3+ and Mn4+ in distinct crystallographic sites, and a nearly perfect orbital ordering of the Mn3+ octahedra.

  15. Cochlear Implants

    Science.gov (United States)

    A cochlear implant is a small, complex electronic device that can help to provide a sense of sound. People who are ... of-hearing can get help from them. The implant consists of two parts. One part sits on ...

  16. Cochlear Implants

    Science.gov (United States)

    ... imaging (MRI) scans, to evaluate your inner ear anatomy. Cochlear implant surgery Cochlear implant surgery is usually performed as an outpatient procedure under general anesthesia. An incision is made behind the ear ...

  17. Local activation of uterine Toll-like receptor 2 and 2/6 decreases embryo implantation and affects uterine receptivity in mice.

    Science.gov (United States)

    Sanchez-Lopez, Javier Arturo; Caballero, Ignacio; Montazeri, Mehrnaz; Maslehat, Nasim; Elliott, Sarah; Fernandez-Gonzalez, Raul; Calle, Alexandra; Gutierrez-Adan, Alfonso; Fazeli, Alireza

    2014-04-01

    Embryo implantation is a complex interaction between maternal endometrium and embryonic structures. Failure to implant is highly recurrent and impossible to diagnose. Inflammation and infections in the female reproductive tract are common causes of infertility, embryo loss, and preterm labor. The current work describes how the activation of endometrial Toll-like receptor (TLR) 2 and 2/6 reduces embryo implantation chances. We developed a morphometric index to evaluate the effects of the TLR 2/6 activation along the uterine horn (UH). TLR 2/6 ligation reduced the endometrial myometrial and glandular indexes and increased the luminal index. Furthermore, TLR 2/6 activation increased the proinflammatory cytokines such as interleukin (IL)-1beta and monocyte chemotactic protein (MCP)-1 in UH lavages in the preimplantation day and IL-1 receptor antagonist in the implantation day. The engagement of TLR 2/6 with its ligand in the UH during embryo transfer severely affected the rate of embryonic implantation (45.00% ± 6.49% vs. 16.69% ± 5.01%, P embryo implantation process was verified using an in vitro model of human embryo implantation where trophoblast spheroids failed to adhere to a monolayer of TLR 2- and TLR 2/6-activated endometrial cells. The inhibition of TLR receptors 2 and 6 in the presence of their specific ligands restored the ability of the spheroids to bind to the endometrial cells. In conclusion, the activation of the innate immune system in the uterus at the time of implantation interfered with the endometrial receptivity and reduced the chances of implantation success.

  18. Local structure, magnetization and Griffiths phase of self-doped La{sub 1-x}MnO{sub 3+{delta}} manganites

    Energy Technology Data Exchange (ETDEWEB)

    Ulyanov, A.N., E-mail: a_n_ulyanov@yahoo.com [Donetsk Physico-Technical Institute of National Academy of Sciences, 83114 Donetsk (Ukraine); Pismenova, N.E. [Donetsk Physico-Technical Institute of National Academy of Sciences, 83114 Donetsk (Ukraine); Yang, D.S. [Department of Physics Education, Chungbuk National University, Cheongju 361-763 (Korea, Republic of); Krivoruchko, V.N.; Levchenko, G.G. [Donetsk Physico-Technical Institute of National Academy of Sciences, 83114 Donetsk (Ukraine)

    2013-02-15

    Highlights: Black-Right-Pointing-Pointer Mn{sup 3+} ions form the anti-site defects in A-site of ABO{sub 3} perovskite cell for x > 0.1 sample. Black-Right-Pointing-Pointer Griffiths-like singularity is originated by strain accommodation field. Black-Right-Pointing-Pointer Strain accommodation is caused by the vacancies in A- and B-sites of the perovskite cell. - Abstract: Self-doped La{sub 1-x}MnO{sub 3+{delta}} manganites (x = 0.0, 0.05, 0.1, and 0.15) have been studied by X-ray diffraction, X-ray absorption near K-edge spectroscopy and magnetization measurements. The x = 0.0 composition is the orthorhombic Pnma phase with a small amount of the rhombohedral R3{sup Macron }c one, the compounds with x = 0.05, 0.1 and 0.15 exhibit the R3{sup Macron }c space group. The Curie temperature, T{sub C}, increases with x increase substantially. The T{sub C} of the x = 0.1 and x = 0.15 samples are almost the same, but magnetization of the x = 0.15 composition is much higher than that of the x = 0.1 sample. The results for the x = 0.15 sample are in agreement with the suggestion that a part of manganese ions, being in a trivalent state, occupies a vacant A-site of the perovskite ABO{sub 3} cell. Magnetic behavior of the samples above T{sub C} exhibits Griffiths-like features. The observed Griffiths singularity is suggested to be due to strain accommodation caused by the vacancies in the A- and B-positions of the ABO{sub 3} perovskite cell.

  19. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ...

  20. Insectivores (Erinaceomorpha, Soricomorpha; Mammalia) from Karydia and Komotini (Thrace, Greece; MN 4/5)

    NARCIS (Netherlands)

    Doukas, C.S.; Hoek Ostende, van den L.W.

    2006-01-01

    The insectivores from the Thrace locality of Karydia (MN 4) are described, as well as an erinaceid molar from thenearby locality of Komotini (MN 5). The Karydia assemblagecontains the same genera of the Greek MN 4 localityAliveri, with the addition of a shrew and of Plesiosorex. An M2 of the latter

  1. High-dose-rate brachytherapy with local injection of bleomycin for N0 oral tongue cancer. Possibilities of the control of tumor implant by inserting applicators and the decrease in tumor dose

    Energy Technology Data Exchange (ETDEWEB)

    Ohga, Saiji; Uehara, Satoru [National Kyushu Medical Center Hospital, Fukuoka (Japan); Miyoshi, Makoto [Kitakyushu Municipal Medical Center Hospital, Fukuoka (Japan); Jingu, Kenichi [Fukuoka Univ. (Japan). School of Medicine

    2003-01-01

    Twenty-eight patients with N0 oral tongue cancer were treated with high-dose-rate (HDR) interstitial brachytherapy combined with local injection of bleomycin between December 1997 and June 2001 at the Department of Radiology, National Kyushu Medical Center Hospital. A median dose of 5 mg of bleomycin was injected locally, and 16-20 Gy was delivered to the area surrounding applicators for control of the tumor implant during the initial two days. The two-year local recurrence-free survival rate was 96% [T1, 2: 100% (8/8, 15/15), T3: 80% (4/5)]. The two-year secondary neck node metastasis rate was 7.1% [T1: 12.5% (1/8), T2: 6.7% (1/15), T3: 0% (0/5)]. There were no tumor implants in any patients. We tried to decrease the minimal tumor dose step by step. The groups with median minimal tumor doses of 60 Gy, 50 Gy, and 40 Gy had local recurrence rates of 12.5% (1/8), 0% (0/14), and 0% (0/6), respectively. Local recurrence rates were not increased by decreasing the minimal tumor dose. Two patients (7%) had secondary neck node metastasis. Late adverse effects were tongue ulcer: 11% (3/28), oral floor ulcer: 4% (1/28), and osteonecrosis: 4% (1/28). These results suggest that control of the tumor implant and the decrease in minimal tumor dose below 60 Gy may be possible with the local injection of bleomycin and delivery of doses to the area surrounding the applicators when N0 tongue cancer is treated using {sup 192}Ir-HDR brachytherapy. (author)

  2. Lattice location and local magnetism of recoil implanted Fe impurities in wide and narrow band semiconductors CdTe, CdSe, and InSb: Experiment and theory

    Energy Technology Data Exchange (ETDEWEB)

    Mohanta, S. K.; Mishra, S. N. [Tata Institute of Fundamental Research (TIFR), Homi Bhabha Road, Mumbai 400005 (India)

    2014-05-07

    Employing the time differential perturbed angular distribution method, we have measured local susceptibility and spin relaxation rate of {sup 54}Fe nuclei implanted in III-V and II-VI semiconductors, CdTe, CdSe, and InSb. The magnetic response of Fe, identified to occupy the metal as well as the semi-metal atom sites, exhibit Curie-Weiss type susceptibility and Korringa like spin relaxation rate, revealing the existence of localized moments with small spin fluctuation temperature. The experimental results are supported by first principle electronic structure calculations performed within the frame work of density functional theory.

  3. Localization of electrons due to orbitally ordered bi-stripes in the bilayer manganite La2-2xSr1+2xMn2O7 (x ∼ 0.59)

    Science.gov (United States)

    Sun, Z.; Wang, Q.; Fedorov, A. V.; Zheng, H.; Mitchell, J. F.; Dessau, D. S.

    2011-01-01

    Electronic phases with stripe patterns have been intensively investigated for their vital roles in unique properties of correlated electronic materials. How these real-space patterns affect the conductivity and other properties of materials (which are usually described in momentum space) is one of the major challenges of modern condensed matter physics. By studying the electronic structure of La2-2xSr1+2xMn2O7 (x ∼ 0.59) and in combination with earlier scattering measurements, we demonstrate the variation of electronic properties accompanying the melting of so-called bi-stripes in this material. The static bi-stripes can strongly localize the electrons in the insulating phase above Tc ∼ 160 K, while the fraction of mobile electrons grows, coexisting with a significant portion of localized electrons when the static bi-stripes melt below Tc. The presence of localized electrons below Tc suggests that the melting bi-stripes exist as a disordered or fluctuating counterpart. From static to melting, the bi-stripes act as an atomic-scale electronic valve, leading to a “colossal” metal-insulator transition in this material. PMID:21715662

  4. Implantable Microimagers

    Directory of Open Access Journals (Sweden)

    Jun Ohta

    2008-05-01

    Full Text Available Implantable devices such as cardiac pacemakers, drug-delivery systems, and defibrillators have had a tremendous impact on the quality of live for many disabled people. To date, many devices have been developed for implantation into various parts of the human body. In this paper, we focus on devices implanted in the head. In particular, we describe the technologies necessary to create implantable microimagers. Design, fabrication, and implementation issues are discussed vis-à-vis two examples of implantable microimagers; the retinal prosthesis and in vivo neuro-microimager. Testing of these devices in animals verify the use of the microimagers in the implanted state. We believe that further advancement of these devices will lead to the development of a new method for medical and scientific applications.

  5. Mn3{ital s} multiplet splitting of pseudomorphic Mn overlayers on Ru(001)

    Energy Technology Data Exchange (ETDEWEB)

    Sham, T.K. [Department of Chemistry, The University of Western Ontario, London N6A 5B7 (Canada); Shek, M.L. [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, New York 11973 (United States); Hrbek, J.; Campen, D.G. [Chemistry Department, Brookhaven National Laboratory, Upton, New York 11973 (United States)

    1996-07-01

    The Mn3{ital s} multiplet splitting for a series of Mn overlayers on Ru(001) has been measured with synchrotron radiation photoemission spectroscopy. These overlayers were prepared by vapor deposition of Mn onto a Ru(001) substrate at a monolayer/minute dosing rate at room temperature. Under these conditions, the Mn overlayers grow pseudomorphically to multilayer coverages. It is found that this system exhibits a noticeable increase in the Mn3{ital s} multiplet splitting and a positive binding energy shift as the coverage increases from monolayer to multilayer (12 ML). These results are attributed to the increase in the atomic volume, and hence the local magnetic moment at the Mn site on the average, with increasing coverage. {copyright} {ital 1996 American Vacuum Society}

  6. Experimental bond critical point and local energy density properties determined for Mn-O, Fe-O, and Co-O bonded interactions for tephroite, Mn2SiO4, fayalite, Fe2SiO4, and Co2SiO4 olivine and selected organic metal complexes: comparison with properties calculated for non-transition and transition metal M-O bonded interactions for silicates and oxides.

    Science.gov (United States)

    Gibbs, G V; Downs, R T; Cox, D F; Rosso, K M; Ross, N L; Kirfel, A; Lippmann, T; Morgenroth, W; Crawford, T D

    2008-09-18

    Bond critical point (bcp) and local energy density properties for the electron density (ED) distributions, calculated with first-principle quantum mechanical methods for divalent transition metal Mn-, Co-, and Fe-containing silicates and oxides are compared with experimental model ED properties for tephroite, Mn 2SiO 4, fayalite, Fe 2SiO 4, and Co 2SiO 4 olivine, each determined with high-energy synchrotron single-crystal X-ray diffraction data. Trends between the experimental bond lengths, R(M-O), (M = Mn, Fe, Co), and the calculated bcp properties are comparable with those observed for non-transition M-O bonded interactions. The bcp properties, local total energy density, H( r c), and bond length trends determined for the Mn-O, Co-O, and Fe-O interactions are also comparable. A comparison is also made with model experimental bcp properties determined for several Mn-O, Fe-O, and Co-O bonded interactions for selected organometallic complexes and several oxides. Despite the complexities of the structures of the organometallic complexes, the agreement between the calculated and model experimental bcp properties is fair to good in several cases. The G( r c)/rho( r c) versus R(M-O) trends established for non-transition metal M-O bonded interactions hold for the transition metal M-O bonded interactions with G( r c)/rho( r c) increasing in value as H( r c) becomes progressively more negative in value, indicating an increasing shared character of the interaction as G( r c)/rho( r c) increases in value. As observed for the non-transition metal M-O bonded interactions, the Laplacian, nabla (2)rho( r c), increases in value as rho( r c) increases and as H( r c) decreases and becomes progressive more negative in value. The Mn-O, Fe-O, and Co-O bonded interactions are indicated to be of intermediate character with a substantial component of closed-shell character compared with Fe-S and Ni-S bonded interactions, which show greater shared character based on the | V( r c)|/ G( r c

  7. Contraceptive implants: current perspectives

    Directory of Open Access Journals (Sweden)

    Rowlands S

    2014-09-01

    Full Text Available Sam Rowlands,1,2 Stephen Searle3 1Centre of Postgraduate Medical Research and Education, School of Health and Social Care, Bournemouth University, Bournemouth, United Kingdom; 2Dorset HealthCare, Bournemouth, United Kingdom; 3Sexual Health Services, Chesterfield, United KingdomAbstract: Progestin-only contraceptive implants are a highly cost-effective form of long-acting reversible contraception. They are the most effective reversible contraceptives and are of a similar effectiveness to sterilization. Pregnancies are rare in women using this method of contraception, and those that do occur must be fully investigated, with an ultrasound scan of the arm and serum etonogestrel level if the implant cannot be located. There are very few contraindications to use of implants, and they have an excellent safety profile. Both acceptability and continuation with the method are high. Noncontraceptive benefits include improvements in dysmenorrhea, ovulatory pain, and endometriosis. Problematic bleeding is a relatively common adverse effect that must be covered in preinsertion information-giving and supported adequately if it occurs. Recognized training for both insertion and removal should be undertaken. Care needs to be taken at both insertion and removal to avoid neurovascular injury. Implants should always be palpable; if they are not, noninsertion should be assumed until disproven. Etonogestrel implants are now radiopaque, which aids localization. Anticipated difficult removals should be performed by specially trained experts. Keywords: contraceptive, subdermal implant, etonogestrel, levonorgestrel, progestin-only, long-acting reversible contraception

  8. Morphological Studies of Local Influence of Implants with Coatings Based on Superhard Compounds on Bone Tissue under Conditions of Induced Trauma

    Directory of Open Access Journals (Sweden)

    Galimzyan KABIROV

    2015-07-01

    Full Text Available In this paper we analyze the response of bone tissue to a transosseous introduction of implants made of copper (Cu, medical steel 12X18H9T, steel with nitrides of titanium and hafnium coatings (TiN + HfN, as well as steel coated with titanium and zirconium nitrides (TiN + ZrN into the diaphysis of the tibia of experimental rats. The obtained results showed that the restoration of the injured bone and bone marrow in groups with implants made of steel 12X18H9T occurred without the participation of the granulation and cartilaginous tissues, but with implants made of steel coated with titanium and hafnium nitrides (TiN + HfN, this bone recovery also took place in the early term. At the same time, in groups, where the implants were made of copper (Cu, implants were made of steel coated with titanium and zirconium nitrides (TiN + ZrN were used, such phenomena as necrosis, lysis and destruction of the bone were registered and the bone tissue repair went through formation of the cartilaginous tissue.

  9. Magnetism of carbon doped Mn5Si3 and Mn5Ge3 films

    Indian Academy of Sciences (India)

    C Sürgers; K Potzger; G Fischer

    2009-03-01

    The magnetic properties of Mn5Si3C and Mn5Ge3C films prepared by magnetron cosputtering or C+-ion implantation are studied. The carbon-doped films exhibit ferromagnetic properties with Curie temperatures C well above room temperature and metallic conductivity, making them possible candidates for future magnetic semiconductor-based devices. In Mn5Si3C, the carbon gives rise to a lattice expansion and a concomitant change of the magnetic order from antiferromagnetic Mn5Si3 to ferromagnetic Mn5Si3C0.8 with C = 350 K. Likewise, C of ferromagnetic Mn5Ge3 is strongly enhanced in Mn5Ge3C0.8. However, in this case the lattice is slightly compressed by carbon. This demonstrates that the effect of carbon on the magnetic behaviour in these compounds is not simply due to a change of the various interatomic distances by carbon but also due to a modification of the electronic band structure.

  10. Divalent Mn in calcium hydroxyapatite by pulse laser deposition.

    Science.gov (United States)

    Mayer, I; Peto, G; Karacs, A; Molnár, G; Popov, I

    2010-10-01

    Pulse laser deposition (PLD) was used to deposit Mn containing calcium hydroxyapatite (HAMn). The PLD process ensures that the composition of the target and the deposited layer is the same. In some cases additional effort should be made to preserve some volatile components, namely OH. This was ensured by water steam supply. Calcium hydroxyapatite deposited by this method has the same properties as the target in respect to lattice parameters and valence state of Mn, which ensures the fixation between hard tissue and metal implants. This fact makes PLD grown HAMn layer covering implants to be improved for practical use.

  11. Alterações no local de inserção e satisfação com o método entre usuárias de implantes contraceptivos subdérmicos

    OpenAIRE

    Raquel Ferreira Ferraz do Lago Doria

    2010-01-01

    Resumo: Avaliar a prevalência de sinais e sintomas no local de inserção no braço e a opinião das mulheres com relação à satisfação com o método e com o novo padrão de sangramento em usuárias de implantes subdérmicos liberadores de levonorgestrel (LNG; Jadelle®) e etonogestrel (ENG; Implanon®). Métodos: Os totais de 233 e 226 mulheres foram aceitas nos grupos de implantes liberadores de ENG e LNG, respectivamente. Os sinais locais foram avaliados pela inspeção e as mulheres foram questionadas ...

  12. (55)Mn pulsed ENDOR spectroscopy of Mn(2+) ions in ZnO thin films and single crystal.

    Science.gov (United States)

    Böttcher, Rolf; Pöppl, Andreas; Lorenz, Michael; Friedländer, Stefan; Spemann, Daniel; Grundmann, Marius

    2014-08-01

    (55)Mn pulsed electron nuclear double resonance (ENDOR) experiments were performed at X-band on high spin S=5/2 Mn(2+) ions incorporated at zinc lattice sites in heteroepitaxial ZnO thin films. The films have been prepared by pulsed laser deposition and the manganese ions were doped during the growth process. We examine how the c/a lattice axes ratio of the ZnO films influences the (55)Mn hyperfine (hf) and nuclear quadrupole (nq) coupling parameters of the Mn(2+) probe ions. The results are compared with those obtained for Mn(2+) ions present as impurities in ZnO single crystals and revealed that the (55)Mn nq coupling monitors sensitively the structural distortions in the bonding environment of the Mn(2+) ions. The experiments provided the full axially symmetric (55)Mn hf and nq interaction tensors. The latter is found to be very sensitive to small axial distortions of the MnO4 tetrahedrons. In particular, the (55)Mn pulsed ENDOR spectra of the ZnO:Mn thin films are strongly subjected to strain effects in the nq coupling parameter indicating a variation of the local structural parameters for the heteroepitaxial films. In the analysis of the (55)Mn pulsed ENDOR spectra the axial and cubic zero field splitting of the Mn(2+) ions was taken into account and intensity effects in the ENDOR spectra due to the zero field splitting effects were discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Bone quality at the implant site after reconstruction of a local defect of the maxillary anterior ridge with chin bone or deproteinised cancellous bovine bone.

    Science.gov (United States)

    Meijndert, L; Raghoebar, G M; Schüpbach, P; Meijer, H J A; Vissink, A

    2005-12-01

    The purpose of this study was to investigate the quality of bone at grafted implant sites in the anterior maxilla. Grafting of these sites was necessary because of insufficient bone volume in a buccopalatinal direction (width at the top of the crest 1-3mm). Reconstruction was performed with chin bone (N=5), chin bone and a resorbable Bio-Gide GBR membrane (N=5) or Bio-Oss spongiosa granules in combination with a Bio-Gide GBR membrane (N=5). Biopsies were taken prior to implantation, i.e. 3 months after grafting with chin bone, and 6 months after grafting with Bio-Oss. Evaluation was done by assessing the histological and histomorphometric characteristics of full-length biopsies taken from the actual implant site. Both areas with non-vital bone and areas with apposition of bone and remodelling phenomena were observed in the chin bone group at the time of placement of the implants. Similar results were observed at implant sites reconstructed with a chin bone graft covered by a membrane. In the chin bone group without and with a GBR membrane, the mean total bone volume (TBV) was 55.2+/-6.8% and 57.7+/-11.5%, respectively; the marrow connective tissue volume (MCTV) was 44.8+/-6.8% and 42.3+/-11.5%, respectively. Remnants of the resorbable GBR membrane were not detected. In the Bio-Oss((R)) group, at implant placement some newly formed bone was observed in the connective tissue surrounding the Bio-Oss((R)) particles (mean TBV (newly formed bone) 17.6+/-14.5%), but most particles were surrounded by connective tissue. No convincing signs of remodelling were observed (mean remaining Bio-Oss volume 40.5+/-9.3%; mean MCTV 41.9+/-13.1%). No implants were lost during follow up (12 months). At the time of placement of the implants the grafting material (either chin bone or Bio-Oss is still not fully replaced by new vital bone. In case of Bio-Oss, most of the grafting material is even still present. Despite these differences, the 1-year clinical results were very good and

  14. Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode arrays.

    Science.gov (United States)

    Boyer, Eric; Karkas, Alexandre; Attye, Arnaud; Lefournier, Virginie; Escude, Bernard; Schmerber, Sebastien

    2015-03-01

    To compare the incidence of dislocation of precurved versus straight flexible cochlear implant electrode arrays using cone-beam computed tomography (CBCT) image analyses. Consecutive nonrandomized case-comparison study. Tertiary referral center. Analyses of patients' CBCT images after cochlear implant surgery. Precurved and straight flexible electrode arrays from two different manufacturers were implanted. A round window insertion was performed in most cases. Two cases necessitated a cochleostomy. The patients' CBCT images were reconstructed in the coronal oblique, sagittal oblique, and axial oblique section. The insertion depth angle and the incidence of dislocation from the scala tympani to the scala vestibuli were determined. The CBCT images and the incidence of dislocation were analyzed in 54 patients (61 electrode arrays). Thirty-one patients were implanted with a precurved perimodiolar electrode array and 30 patients with a straight flexible electrode array. A total of nine (15%) scalar dislocations were observed in both groups. Eight (26%) scalar dislocations were observed in the precurved array group and one (3%) in the straight array group. Dislocation occurred at an insertion depth angle between 170 and 190 degrees in the precurved array group and at approximately 370 degrees in the straight array group. With precurved arrays, dislocation usually occurs in the ascending part of the basal turn of the cochlea. With straight flexible electrode arrays, the incidence of dislocation was lower, and it seems that straight flexible arrays have a higher chance of a confined position within the scala tympani than perimodiolar precurved arrays.

  15. Bone quality at the implant site after reconstruction of a local defect of the maxillary anterior ridge with chin bone or deproteinised cancellous bovine bone

    NARCIS (Netherlands)

    Meijndert, L.; Raghoebar, G.M.; Schüpbach, P.; Meijer, H.J.A.; Vissink, A.

    2005-01-01

    The purpose of this study was to investigate the quality of bone at grafted implant sites in the anterior maxilla. Grafting of these sites was necessary because of insufficient bone volume in a buccopalatinal direction (width at the top of the crest 1 - 3 mm). Reconstruction was performed with chin

  16. Structures of Mn clusters

    Indian Academy of Sciences (India)

    Tina M Briere; Marcel H F Sluiter; Vijay Kumar; Yoshiyuki Kawazoe

    2003-01-01

    The geometries of several Mn clusters in the size range Mn13–Mn23 are studied via the generalized gradient approximation to density functional theory. For the 13- and 19-atom clusters, the icosahedral structures are found to be most stable, while for the 15-atom cluster, the bcc structure is more favoured. The clusters show ferrimagnetic spin configurations.

  17. Effect of local administration of platelet-rich plasma and guided tissue regeneration on the level of bone resorption in early dental implant insertion

    Directory of Open Access Journals (Sweden)

    Duka Miloš

    2008-01-01

    Full Text Available Background/Aim. Osseointegration is a result of cellular migration, differentiation, bone formation, and bone remodeling on the surface of an implant. Each of these processes depends on platelets and blood coagulum. Platelet-rich plasma (PRP is used to improve osseointegration and stability of implants. The aim of the research was to test the influence that PRP and guided tissue regeneration in bone defects have on bone defect filling and the level of bone resorption in early implant insertion. Methods. This experimental study included 10 dogs. A total of 40 BCT implants were inserted, 4 in each dog (two on the left side and two on the right side, with guided tissue regeneration. Radiologic analyses were done immediately after the insertion and 10 weeks after the insertion. Bone defect filling was measured by a graduated probe 10 weeks after the implant insertion. The following protocols were tested: I - PRP in combination with bovine deproteinized bone (BDB and resorptive membrane of bovine origin (RBDM, II - BDB + RBDM, III - PRP + RBDM and IV - RBDM. Results. The applied protocols affected differently the bone defect filling and the level of bone resorption. Significantly better results (the lowest bone resorption were achieved with protocol I (PRP + BDB + RBDM in comparison with protocols III (PRP + RBDM and IV (RBDM, but not with protocol II (BDB + RBDM. On the other hand, no significant difference was found among protocols II (BDB + RBDM, III (PRP + RBDM and IV (RBDM in the level of bone tissue resorption. Conslusion. The bone defect filling was largest and the level of bone resorption was lowest in the protocol with PRP applied in combination with BDB and RBDM.

  18. Influence of bone density on implant stability parameters and implant success: a retrospective clinical study

    Directory of Open Access Journals (Sweden)

    McGlumphy Edwin A

    2008-11-01

    Full Text Available Abstract Background The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT and to investigate the influence of local bone density on implant stability parameters and implant success. Methods A total of 300 implants were placed in 111 patients between 2003 and 2005. The bone density in each implant recipient site was determined using CT. Insertion torque and resonance frequency analysis were used as implant stability parameters. The peak insertion torque values were recorded with OsseoCare machine. The resonance frequency analysis measurements were performed with Osstell instrument immediately after implant placement, 6, and 12 months later. Results Of 300 implants placed, 20 were lost, meaning a survival rate of %. 93.3 after three years (average 3.7 ± 0.7 years. The mean bone density, insertion torque and RFA recordings of all 300 implants were 620 ± 251 HU, 36.1 ± 8 Ncm, and 65.7 ± 9 ISQ at implant placement respectively; which indicated statistically significant correlations between bone density and insertion torque values (p Conclusion CT is a useful tool to determine the bone density in the implant recipient sites, and the local bone density has a prevailing influence on primary implant stability, which is an important determinant for implant success.

  19. Cochlear implant patients underwent successful MRI examination after local bandaging:a case report%电子耳蜗植入术患者局部包扎后行MRI检查成功1例

    Institute of Scientific and Technical Information of China (English)

    保国华; 曹克利

    2012-01-01

    Summary A female patient, now 6 years old. received cochlear implant in the right ear at the age of 2(February .2006). In August 16. 2010. a cervical spine MR1 examination was required due to the cervical spine injury in order to confirm the diagnosis. Considering the cochlea coil may interfere with the MKI examination results, a local bandaging around the ear was given to isolate cochlear magnetic field. The results of cervical spine MR1 ex aminations showed no obvious disturbance, which suggests that we could further explore this method clinically.

  20. Secretory pathway Ca2+/Mn2+-ATPase isoform 2 and lactation: specific localization of plasmalemmal and secretory pathway Ca2+ pump isoforms in the mammary gland

    Energy Technology Data Exchange (ETDEWEB)

    Faddy, Helen M.; Smart, Chanel E.; Xu, Ren; Lee, Genee Y.; Kenny, Paraic A.; Feng, Mingye; Rao, Rajini; Brown, Melissa A.; Bissell, Mina J.; Roberts-Thomson, Sarah J.; Monteith, Gregory R.

    2008-04-09

    The supply of calcium to the developing neonate via milk is an important physiological process. Until recently the mechanism for the enrichment of milk with calcium was thought to be almost entirely mediated via the secretory pathway. However, recent studies suggest that a specific isoform of the plasma membrane calcium ATPase, PMCA2, is the primary mechanism for calcium transport into milk, highlighting a major role for apical calcium transport. We compared the expression of the recently identified secretory calcium ATPase, SPCA2, and SPCA1, in the mouse mammary gland during different stages of development. SPCA2 levels increased over 35 fold during lactation, while SPCA1 increased only a modest two fold. The potential importance of SPCA2 in lactation was also highlighted by its localization to luminal secretory cells of the mammary gland during lactation, while SPCA1 was expressed throughout the cells of the mammary gland. We also observed major differences in the localization of PMCA2 and PMCA1 during lactation. Using the SCp2 mouse mammary epithelial cell 3D culture model, differences in the sub-cellular distribution of PMCA2 and PMCA1 were clear. These studies highlight the likely specific roles of PMCA2 and SPCA2 in lactation, and link the recently characterized SPCA2 calcium pump to the supply of calcium into milk and the regulation of Golgi resident enzymes important in lactation. They also indicate that calcium transport into milk is a complex interplay between apical and secretory pathways.

  1. Iatrogenic Tumor Implantation

    Institute of Scientific and Technical Information of China (English)

    Ying Ma; Ping Bai

    2008-01-01

    Iatrogenic tumor implantation is a condition that results from various medical procedures used during diagnosis or treatment of a malignancy. It involves desquamation and dissemination of tumor cells that develop into a local recurrence or distant metastasis from the tumor under treatment. The main clinical feature of the condition is nodules at the operation's porous channel or incision, which is easily diagnosed in accordance with the case history. Final diagnosis can be made based on pathological examination. Tumor implantation may occur in various puncturing porous channels, including a laparoscopic port, abdominal wall incision, and perineal incision, etc. Besides a malignant tumor,implantation potential exists with diseases, such as a borderline tumor and endometriosis etc. Once a tumor implantation is diagnosed, or suspected, surgical resection is usually conducted.During the diagnosis and treatment of diseases, avoiding and reducing iatrogenic implantation and dissemination has been regarded as an important principle for surgical treatment of tumors. In a clinical practice setting, if possible, excisional biopsy should be employed, if a biopsy is needed. Repeated puncturing should be avoided during a paracentesis. In a laparoscopic procedure, the tissue is first put into a sample bag and then is taken out from the point of incision. After a laparoscopic procedure, the peritoneum, abdominal muscular fasciae, and skin should be carefully closed, and/or the punctured porous channel be excised. In addition, the sample/tissue should be rinsed with distilled water before surgical closure of the abdominal cavity,allowing the exfoliated tumor cells to swell and rupture in the hypo-osmolar solution. Then surgical closure can be conducted following a change of gloves and equipment. The extent of hysteromyomectomy should as far as possible be away from the uterine cavity. The purpose of this study is to make clinicians aware of the possibility of tumor implantation

  2. The effects of local nitroglycerin on the surgical delay procedure in prefabricated flaps by vascular implant in rats Efeitos da nitroglicerina tópica na autonomização de retalhos pré-fabricados por implante vascular em ratos

    Directory of Open Access Journals (Sweden)

    Jairo Zacchê de Sá

    2012-12-01

    Full Text Available PURPOSE: To evaluate the effect of local nitroglycerin on the viable area of a prefabricated flap for vascular implant in rats, and to investigate the surgical delay procedure. METHODS: A femoral pedicle was implanted under the skin of the abdominal wall in forty Wistar rats. The animals were divided into four groups of ten: group 1 - without surgical delay procedure and local nitroglycerin; group 2 - with surgical delay procedure, but without local nitroglycerin; group 3 - without surgical delay procedure, but with local nitroglycerin; and group 4 - with simultaneous surgical delay procedure and local nitroglycerin. The percentages of the viable areas, in relation to the total flap, were calculated using AutoCAD R 14. RESULTS: The mean percentage value of the viable area was 8.9% in the group 1. 49.4% in the group 2; 8.4% in the group 3 and 1.1% in the group 4. There was significant difference between groups 1 and 2 (p=0.005, 1 and 4 (p=0.024, 2 and 3 (p=0.003, 2 and 4 (p=0.001. These results support the hypothesis that the closure of the arterial venous channels is responsible for the phenomenon of surgical delay procedure. CONCLUSION: Local nitroglycerin did not cause an increase in the prefabricated viable flap area by vascular implantation and decreased the viable flap area that underwent delay procedures.OBJETIVO: Avaliar o efeito da nitroglicerina tópica sobre a área viável de um modelo de retalho pré-fabricado por implante vascular em ratos e analisar o mecanismo de autonomização cirúrgica aplicada a retalhos pré-fabricados. MÉTODOS: Foram utilizados 40 ratos Wistar. No primeiro tempo cirúrgico - 20 ratos foram submetidos a implante do pedículo femoral na região subdérmica da parede abdominal, e 20 submetidos à autonomização cirúrgica de retalho cutâneo de parede abdominal e, simultaneamente, implante do pedículo femoral na região subdérmica deste retalho. No segundo tempo - após três semanas e em todos os animais

  3. Goserelin Implant

    Science.gov (United States)

    ... in men (blockage that causes difficulty urinating), or heart or liver disease.tell your doctor if you are pregnant or plan to become pregnant. Goserelin implant should not be used in pregnant women, except ...

  4. Implant fixation by bone ingrowth.

    Science.gov (United States)

    Kienapfel, H; Sprey, C; Wilke, A; Griss, P

    1999-04-01

    The term osseointegration referred originally to an intimate contact of bone tissue with the surface of a titanium implant; the term bone ingrowth refers to bone formation within an irregular (beads, wire mesh, casting voids, cut grooves) surface of an implant. The section dealing with the historical background describes the development of macroporous, microporous, and textured surfaces with an emphasis on the evolution of porous and textured metal surfaces. The principal requirements for osseointegration and bone ingrowth are systematically reviewed as follows: i) the physiology of osseointegration and bone ingrowth, including biomaterial biocompatibility with respect to cellular and matrix response at the interface; ii) the implant surface geometry characteristics; iii) implant micromotion and fixation modes; and iv) the implant-bone interface distances. Based on current methods of bone ingrowth assessment, this article comparatively reviews and discusses the results of experimental studies with the objective of determining local and systemic factors that enhance bone ingrowth fixation.

  5. Contraceptive implants.

    Science.gov (United States)

    McDonald-Mosley, Raegan; Burke, Anne E

    2010-03-01

    Implantable contraception has been extensively used worldwide. Implants are one of the most effective and reversible methods of contraception available. These devices may be particularly appropriate for certain populations of women, including women who cannot use estrogen-containing contraception. Implants are safe for use by women with many chronic medical problems. The newest implant, Implanon (Organon International, Oss, The Netherlands), is the only device currently available in the United States and was approved in 2006. It is registered for 3 years of pregnancy prevention. Contraceptive implants have failure rates similar to tubal ligation, and yet they are readily reversible with a return to fertility within days of removal. Moreover, these contraceptive devices can be safely placed in the immediate postpartum period, ensuring good contraceptive coverage for women who may be at risk for an unintended pregnancy. Irregular bleeding is a common side effect for all progestin-only contraceptive implants. Preinsertion counseling should address possible side effects, and treatment may be offered to women who experience prolonged or frequent bleeding. Thieme Medical Publishers.

  6. Functional anatomy of the postcranial skeleton of Styriofelis lorteti (Carnivora, Felidae, Felinae from the Middle Miocene (MN 6 locality of Sansan (Gers, France

    Directory of Open Access Journals (Sweden)

    Peigné, S.

    2011-12-01

    Full Text Available The postcranial skeleton of the European Middle Miocene feline Styriofelis lorteti has been traditionally known on the basis of fragmentary fossils mainly from the French locality of Sansan. The discovery of an almost complete skeleton in the same site in the excavations of 1990 opened the possibility of unprecedented assessment of the morphology and function of this early felid. In this paper we describe this material, and compare it with a sample of modern and fossil felids, finding a combination of a generally modern morphology, with moderate adaptations to terrestrial locomotion, besides a set of primitive characters linking S. lorteti with earlier felids like Proailurus lemanensis.El esqueleto post-craneal del felino Styriofelis lorteti, del Mioceno medio de Europa, ha sido tradicionalmente conocido en base a fósiles fragmentarios, procedentes principalmente del yacimiento francés de Sansan. El descubrimiento en este yacimiento de un esqueleto casi completo, durante la campaña de 1990, abrió la posibilidad de llevar a cabo un análisis sin precedentes de la morfología y función de este félido primitivo. En este trabajo se describe este material, comparándose con una muestra de felinos fósiles y actuales, hallándose una combinación entre una morfología general moderna, con adaptaciones moderadas para la locomoción terrestre, junto con una serie de caracteres primitivos que relacionan a S. lorteti con los félidos más antiguos como Proailurus lemanensis.

  7. Effects of gold coating on experimental implant fixation

    DEFF Research Database (Denmark)

    Zainali, Kasra; Danscher, Gorm; Jakobsen, Thomas

    2009-01-01

    -kinase activation. The present study investigated whether gilding implant Surfaces augmented early implant osseointegration and implant fixation by its modulatory effect on the local inflammatory response. Ion release was traced by autometallographic silver enhancement. Gold-coated cylindrical porous coated Ti6Al4V....... Histomorphometrical analyses showed gold-coated implants had a decrease in overall total bone-to-implant contact of 35%. Autometallographic analysis revealed few cells loaded with gold close to the gilded implant surface. The findings demonstrate that gilding of implants negatively, affects mechanical strength...

  8. Nano-engineering by implanting Al2O3 nano particle as sandwiched scattering centers in between the Lao.5Pr0.2Sr0.3MnO3 thin film layers.

    Science.gov (United States)

    Markna, J H; Vachhani, P S; Kuberkar, D G; Shah, N A; Misra, P; Singh, B N; Kukreja, L M; Rana, D S

    2009-09-01

    We report the use of non-magnetic Al2O3 nano particles deposited between two ferromagnetic La0.5Pr0.2Sr0.3MnO3 (LPSMO) manganite layers with an aim to improve the electronic and magnetotransport properties of the layered supper lattice grown on single crystal STO(100) substrate using Pulsed Laser Deposition (PLD) technique. We studied the electronic-transport and magnetotransport properties of this system wherein Al2O3 particles are expected to act as insulating scattering centers between two ferromagnetic LPSMO layers. The scattering due to additional scattering centers (insulating Al2O3 nano particles) could be controlled by application of external field, resulting in high magnetoresistance (MR) approximately 72% as compared to pristine LPSMO film (MR approximately 51%) at temperature close to their T(M) values. In addition, incorporation of nanostructured Al2O3 barrier between the two ferromagnetic LPSMO layers results in a 2-3 fold increase in the values of temperature coefficient of resistance (TCR) and the field coefficient of resistance (FCR) as compared to pristine LPSMO film, suggesting the use of such nanoengineered manganite layered structure for better device application.

  9. Cochlear Implant

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In this text, the authors recall the main principles and data ruling cochlear implants. Then, a first circle of technical equipment for assistance is presented. This circle includes: device setting (DS), Electrically evoked Auditory Brainstem Responses (EABR), Neural Response Telemetry (NRT), Stapedial Reflex (SR) and Electrodogram Acquisition (EA). This first cycle becomes more and more important as children are implanted younger and younger; the amount of data available with this assistance makes necessary the use of models (implicit or explicit) to handle this information. Consequently, this field is more open than ever.

  10. Quantitative structural refinement of Mn K edge XANES in LaMnO{sub 3} and CaMnO{sub 3} perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Monesi, C. [Dipartimento di Fisica, Universita di ' Roma Tre' , Via Della Vasca Navale, 84, I-00146 Rome (Italy); Meneghini, C. [Dipartimento di Fisica, Universita di ' Roma Tre' , Via Della Vasca Navale, 84, I-00146 Rome (Italy) and INFM-GILDA, c/o ESRF, Grenoble (France)]. E-mail: meneghini@fis.uniroma3.it; Bardelli, F. [Dipartimento di Fisica, Universita di ' Roma Tre' , Via Della Vasca Navale, 84, I-00146 Rome (Italy); INFM-GILDA, c/o ESRF, Grenoble (France); Benfatto, M. [INFN Laboratori Nazionali di Frascati, Via E. Fermi 40, I-00044 Frascati (Italy); Mobilio, S. [Dipartimento di Fisica, Universita di ' Roma Tre' , Via Della Vasca Navale, 84, I-00146 Rome (Italy); INFM-GILDA, c/o ESRF, Grenoble (France); INFN Laboratori Nazionali di Frascati, Via E. Fermi 40, I-00044 Frascati (Italy); Manju, U. [Solid State and Structural Chemistry Unit, Indian Institute of Science, Bangalore 560 012 (India); Sarma, D.D. [Solid State and Structural Chemistry Unit, Indian Institute of Science, Bangalore 560 012 (India)

    2006-05-15

    The special magnetotransport properties of hole doped manganese perovskites originate from a complex interplay among structural, magnetic and electronic degree of freedom. In this picture the local atomic structure around Mn ions plays a special role and this is the reason why short range order techniques like X-ray absorption spectroscopy (XAS) have been deeply exploited for studying these compounds. The analysis of near edge region features (XANES) of XAS spectra can provide very fine details of the local structure around Mn, complementary to the EXAFS, so contributing to the full understanding of the peculiar physical properties of these materials. Nevertheless the XANES analysis is complicated by the large amount of structural and electronic details involved making difficult the quantitative interpretation. This work exploits the recently developed MXAN code to achieve a full structural refinement of the Mn K edge XANES of LaMnO{sub 3} and CaMnO{sub 3} compounds; they are the end compounds of the doped manganite series La {sub x}Ca{sub 1-x}MnO{sub 3}, in which the Mn ions are present only in one charge state as Mn{sup 3+} and Mn{sup 4+} respectively. The good agreement between the results derived from the analysis of near edge and extended region of the XAS spectra demonstrates that a quantitative picture of the local structure can be obtained from structural refinement of Mn K edge XANES data in these crystalline compounds. The XANES analysis offers, in addition, the possibility to directly achieve information on the topology of local atomic structure around the absorber not directly achievable from EXAFS.

  11. Do high radiation doses in locally advanced prostate cancer patients treated with 103Pd implant plus external beam irradiation cause increased urinary, rectal, and sexual morbidity?

    Science.gov (United States)

    Stone, Nelson N; Cesaretti, Jamie A; Rosenstein, Barry; Stock, Richard G

    2010-01-01

    To investigate the morbidity of higher radiation doses in prostate cancer patients. Five hundred eighty-five men treated with seed implantation and external beam irradiation were followed a median of 5 years (range, 2-11). Hormonal therapy (HT) of 9 months duration was used in 504 (86.2%) patients. The biologic effective dose (BED) was calculated using an alpha/beta of 2. Urinary incontinence (UI) and symptoms (IPSS) were prospectively collected. Rectal morbidity was scored according to the Radiation Therapy Oncology Group (RTOG) scale. Two BED dose groups of 220 Gy (n=136) were used. Comparisons of means were made by Student's t test, and the associations were tested by chi-square analysis (Pearson). Urinary retention developed in 36 (6.2%) and was not associated with BED or IPSS. Retention occurred more often with prostate volume >50 cc (17%, p=0.001). The median change in urinary symptoms (IPSS) was 1. Sixty-one percent with high BED were more likely to have increased postimplant symptoms compared with 39% with lower BED (p=0.025; odds ratio [OR], 1.107; 95% confidence interval [CI], 1.10-1.21). UI occurred in 25 patients (4.3%) and was only associated with a postimplant transurethral resection of the prostate (TURP) (n=25), 16% vs. 2.3% for no TURP (p=0.001; OR, 8; 95% CI, 2.4-27). Of the 373 patients initially potent, 204 (54.7%) maintained potency. Impotence was only associated with age at implant (p=0.001) and HT (p=0.004). Sixty-two (10.6%) patients had Grade 1-2 and 4 patients had Grade 3-4 (0.7%, 2 ulcers and 2 fistulas) rectal complications. Three of the Grade 3/4 complications occurred with a dose 220 Gy does not seem to increase morbidity. (c) 2010 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Optimizing Tc in the (Mn,Cr,Ga)As and (Mn,Ga)(As,P) Ternary Alloys

    OpenAIRE

    Xu, J. L.; van Schilfgaarde, M.

    2005-01-01

    We explore two possible ways to enhance the critical temperature $T_c$ in the dilute magnetic semiconductor Mn$_{0.08}$Ga$_{0.92}$As. Within the context of the double-exchange and RKKY pictures, the ternary alloys Mn$_{x}$Cr$_{0.08-x}$Ga$_{0.92}$As and Mn$_{0.08}$Ga$_{0.92}$As$_y$P$_{1-y}$ might be expected to have $T_c$ higher than the pseudobinary Mn$_{0.08}$Ga$_{0.92}$As. To test whether the expectations from model pictures are confirmed, we employ linear response theory within the local-d...

  13. Magnetic and electrical properties of epitaxial GeMn

    Energy Technology Data Exchange (ETDEWEB)

    Ahlers, Stefan

    2009-01-15

    In this work, GeMn magnetic semiconductors will be investigated. The fabrication of GeMn thin films with Mn contents up to 11.7% was realised with molecular beam epitaxy. At a fabrication temperature of 60 C, the suppression of Mn{sub x}Ge{sub y} phases could reproducibly be obtained. Dislocation free epitaxy of diamond-lattice type GeMn thin films was observed. In all fabrication conditions where Mn{sub x}Ge{sub y} suppression was feasible, an inhomogeneous dispersion of Mn was observed in form of a self-assembly of nanometre sized, Mn rich regions in a Ge rich matrix. Each Mn rich region exhibits ferromagnetic coupling with high Curie temperatures exceeding, in part, room temperature. The local ferromagnetic ordering leads to the formation of large, spatially separated magnetic moments, which induce a superparamagnetic behaviour of the GeMn thin films. At low temperatures {<=} 20 K, remanent behaviour was found to emerge. X-ray absorption experiments revealed a similarity of the Mn incorporation in diamond-lattice type GeMn thin films and in the hexagonal lattice of the intermetallic Mn{sub 5}Ge{sub 3} phase, respectively. These tetrahedra represent building blocks of the Mn{sub 5}Ge{sub 3} unit cell. The incorporation of Mn{sub 5}Ge{sub 3} building blocks was found to be accompanied by local structural disorder. The electrical properties of GeMn thin films were addressed by transport measurements. It was shown that by using a n-type Ge substrate, a pn energy barrier between epilayers and substrate to suppress parallel substrate conduction paths can be introduced. With the pn barrier concept, first results on the magnetotransport behaviour of GeMn thin films were obtained. GeMn was found to be p-type, but of high resistivity. a series of GeMn thin films was fabricated, where intermetallic Mn{sub x}Ge{sub y} phase separation was supported in a controlled manner. Phase separation was found to result in the formation of partially coherent, nanometre sized Mn{sub 5

  14. Structure and properties of Mn4Cl9: An antiferromagnetic binary hyperhalogen

    Science.gov (United States)

    Li, Yawei; Zhang, Shunhong; Wang, Qian; Jena, Puru

    2013-02-01

    Calculations based on density functional theory show that the structure of Mn4Cl9 anion is that of a Mn atom at the core surrounded by three MnCl3 moieties. Since Mn is predominantly divalent and MnCl3 is known to be a superhalogen with a vertical detachment energy (VDE) of 5.27 eV, Mn4Cl9 can be viewed as a hyperhalogen with the formula unit Mn(MnCl3)3. Indeed, the calculated VDE of Mn4Cl9 anion, namely 6.76 eV, is larger than that of MnCl3 anion. More importantly, unlike previously discovered hyperhalogens, Mn4Cl9 is the first such hyperhalogen species composed of only two constituent atoms. We further show that Mn4Cl9 can be used as a ligand to design molecules with even higher VDEs. For example, Li[Mn(MnCl3)3]2 anion has a VDE of 7.26 eV. These negatively charged clusters are antiferromagnetic with most of the magnetic moments localized at the Mn sites. Our studies show new pathways for creating binary hyperhalogens.

  15. Effect of P-anion codoping on the Curie temperature of GaMnAs diluted magnetic semiconductors

    Science.gov (United States)

    Bouzerar, Richard; Máca, Frantisek; Kudrnovský, Josef; Bergqvist, Lars

    2010-07-01

    Recent measurements of GaMnAs alloy samples with a very small content of P atoms prepared by ion-implanted pulsed laser melting (II-PLM) [Phys. Rev. Lett. 101, 087203 (2008)10.1103/PhysRevLett.101.087203] have shown surprisingly low Curie temperature as compared to undoped samples. An explanation based on a possible metal-insulator transition at constant Mn doping was proposed based on a dramatic increase of the sample resistivity. However, no quantitative calculations supporting such a picture as concerns the Curie temperature were shown. We will present a parameter-free theory of the Curie temperature (TC) which assumes that possible defects due to the II-PLM such as, e.g., space inhomogeneities, vacancies, clustering, and also conventional compensating defects will reduce the sample hole concentration. Their effect was first qualitatively modeled in the framework of the rigid-band model by adjusting the system Fermi level due to the reduction of the carrier concentration which is considered as a parameter of the theory. In addition, the effect of possible conventional compensating defects, such as, e.g., As and P antisites or P and Mn interstitials was also investigated. TC ’s are calculated within the self-consistent local RPA (SCLRPA) and Monte Carlo (MC) simulations. We will demonstrate that a reasonable agreement of calculated and measured TC can be obtained for reduced hole concentrations which are known to exist in GaMnAs samples. As concerns possible specific defects, we have shown that P and Mn interstitials are particularly effective in the reduction of the sample Curie temperature.

  16. Mn K-edge XANES spectra of manganites measured by Kbeta emission.

    Science.gov (United States)

    García, J; Sánchez, M C; Subías, G; Blasco, J; Proietti, M G

    2001-03-01

    The electronic state of Mn atoms in mixed valence manganites has been studied by means of X-ray absorption spectroscopy at the Mn K-edge. Higher resolution than in conventional measurements has been achieved by measuring the Mn Kbeta fluorescence line. We have found a unique resonance at the edge in the XANES spectra of intermediate composition RE1-xCa(x)MnO3 samples. The features of these XANES spectra do not depend on small changes in the local structure around the Mn atom. However, the spectra of the intermediate composition samples can not be reproduced by a linear combination of REMnO3 and CaMnO3 spectra. Accordingly, the electronic state of Mn atoms in these compounds can not be considered as a mixture of Mn3+ and Mn4+ pure states.

  17. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2016-10-14

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. X-ray absorption near-edge structure and valence state of Mn in (Ga,Mn)N

    Science.gov (United States)

    Titov, A.; Biquard, X.; Halley, D.; Kuroda, S.; Bellet-Amalric, E.; Mariette, H.; Cibert, J.; Merad, A. E.; Merad, G.; Kanoun, M. B.; Kulatov, E.; Uspenskii, Yu. A.

    2005-09-01

    The band structure of the diluted magnetic semiconductor (Ga,Mn)N, and the x-ray absorption near-edge structure (XANES) at the K edge of Mn, were calculated using the linearized augmented plane wave method. The calculated K-edge spectra fit well with experimental data obtained on samples of Ga1-xMnxN with a wide range of Mn content, from x=0.3% to 5.7%. These samples were grown by molecular beam epitaxy. X-ray diffraction measurements and extended x-ray absorption fine structure studies were used to confirm the wurtzite structure of the samples, the absence of any secondary phase, and the substitutional position of Mn in the gallium sublattice of GaN. The shape of the measured XANES spectra does not depend on the Mn content, implying the same valence state and local atomic structure around the Mn atom in all samples. The comparison between the measured spectra and the results of the ab initio calculation offers a clear interpretation of the preedge structure: It is mainly due to dipolar transitions, with a single peak in the case of Mn2+ and an additional peak for Mn3+ . Such a behavior of the XANES preedge of Mn2+ was confirmed experimentally on (Ga,Mn)As and (Zn,Mn)Te. We conclude that the valence state of Mn in wurtzite (Ga,Mn)N is 3+ , a conclusion which is also supported by infrared optical transmission and magnetization data obtained on the same samples.

  19. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  20. Prevalence of peri-implantitis in patients with implant-supported fixed prostheses.

    Science.gov (United States)

    Schuldt Filho, Guenther; Dalago, Haline Renata; Oliveira de Souza, João Gustavo; Stanley, Kyle; Jovanovic, Sascha; Bianchini, Marco Aurélio

    2014-01-01

    The purpose of this study was to evaluate periimplantitis prevalence in patients using implant-supported fixed prostheses that did not have any routine maintenance care. A total of 161 implants (27 patients) were evaluated in patients using implant-supported fixed prostheses. Collected data included information related to patient general health and local factors such as characteristics of implants, time in function, type of loading, positioning, Modified Bleeding Index, bacterial plaque, bleeding on probing (BOP), marginal recession, probing depth (PD), keratinized mucosa, and radiographic bone loss (BL). Factors related to the prostheses were also evaluated. The exclusion criteria were patients that have had any follow-up visit for plaque control of the prosthesis and/or the implants. From a total of 161 implants, 116 (72%) presented without peri-implantitis (PD > 4 mm + BOP + BL > 2 mm) while 45 (28%) had some sign of the disease. Implants placed in the maxilla were 2.98 times more likely to develop the disease (P implantitis (P implants with less than 3 mm interimplant distance were three times more likely to have peri-implantitis. There was no statistical relevance considering other analyses. It can be concluded that patients aged ≤ 60 years have a greater chance of presenting periimplantitis, as well as for implants positioned in the maxilla and those placed with an interimplant distance < 3 mm.

  1. Benthic foraminiferal Mn / Ca ratios reflect microhabitat preferences

    Science.gov (United States)

    Koho, Karoliina A.; de Nooijer, Lennart J.; Fontanier, Christophe; Toyofuku, Takashi; Oguri, Kazumasa; Kitazato, Hiroshi; Reichart, Gert-Jan

    2017-06-01

    The Mn / Ca of calcium carbonate tests of living (rose-Bengal-stained) benthic foraminifera (Elphidium batialis, Uvigerina spp., Bolivina spissa, Nonionellina labradorica and Chilostomellina fimbriata) were determined in relation to pore water manganese (Mn) concentrations for the first time along a bottom water oxygen gradient across the continental slope along the NE Japan margin (western Pacific). The local bottom water oxygen (BWO) gradient differs from previous field study sites focusing on foraminiferal Mn / Ca and redox chemistry, therefore allowing further resolution of previously observed trends. The Mn / Ca ratios were analysed using laser ablation inductively coupled plasma-mass spectrometer (ICP-MS), allowing single-chamber determination of Mn / Ca. The incorporation of Mn into the carbonate tests reflects environmental conditions and is not influenced by ontogeny. The inter-species variability in Mn / Ca reflected foraminiferal in-sediment habitat preferences and associated pore water chemistry but also showed large interspecific differences in Mn partitioning. At each station, Mn / Ca ratios were always lower in the shallow infaunal E. batialis, occupying relatively oxygenated sediments, compared to intermediate infaunal species, Uvigerina spp. and B. spissa, which were typically found at greater depth, under more reducing conditions. The highest Mn / Ca was always recorded by the deep infaunal species N. labradorica and C. fimbriata. Our results suggest that although partitioning differs, Mn / Ca ratios in the intermediate infaunal taxa are promising tools for palaeoceanographic reconstructions as their microhabitat exposes them to higher variability in pore water Mn, thereby making them relatively sensitive recorders of redox conditions and/or bottom water oxygenation.

  2. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  3. Formation of self-organized Mn3O4 nanoinclusions in LaMnO3 films

    Directory of Open Access Journals (Sweden)

    Alberto Pomar

    2016-09-01

    Full Text Available We present a single-step route to generate ordered nanocomposite thin films of secondary phase inclusions (Mn3O4 in a pristine perovskite matrix (LaMnO3 by taking advantage of the complex phase diagram of manganese oxides. We observed that in samples grown under vacuum growth conditions from a single LaMnO3 stoichiometric target by Pulsed Laser Deposition, the most favourable mechanism to accommodate Mn2+ cations is the spontaneous segregation of self-assembled wedge-like Mn3O4 ferrimagnetic inclusions inside a LaMnO3 matrix that still preserves its orthorhombic structure and its antiferromagnetic bulk-like behaviour. A detailed analysis on the formation of the self-assembled nanocomposite films evidences that Mn3O4 inclusions exhibit an epitaxial relationship with the surrounding matrix that it may be explained in terms of a distorted cubic spinel with slight (~9º c-axis tilting. Furthermore, a Ruddlesden-Popper La2MnO4 phase, helping to the stoichiometry balance, has been identified close to the interface with the substrate. We show that ferrimagnetic Mn3O4 columns influence the magnetic and transport properties of the nanocomposite by increasing its coercive field and by creating local areas with enhanced conductivity in the vicinity of the inclusions.

  4. Electronic structure of perovskite LaMnO{sub 3} and CaMnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Chen, B.; Zhao, Y. [University of NSW, Sydney (Australia). School of Materials Science and Engineering; Zheng, X. [University of Sydney, NSW (Australia). School of Chemistry

    1996-12-31

    Perovskite structured lanthanum manganite (LaMnO{sub 3}) can be made to exhibit both strong ferromagnetism and metallic conductivity by partial substitution of La ions (3+ valence) with 2+ valence ions such as Ca. The electronic structures of LaMnO{sub 3} and CaMnO{sub 3} were calculated using Hartree Fock-linear combination of atomic orbitals (LCAO) and Local Density-Molecular Dynamics programs. The band structure show that both are isolators. The valence energy bands are highly degenerated at {Gamma} point in reciprocal space for LaMnO{sub 3}. The conduction bands are partly degenerated in both structures. The dispersion of valence band of LaMnO{sub 3} is about 1.7 eV and the dispersion of conduction band is about 2.0 eV from {Gamma} point to M point. The top two valence bonds of CaMnO{sub 3} are quite flat. The conduction band disperse down significantly, this behaviour could give some reasons why Ca doped LaMnO{sub 3} is metallic conductor. The energy gap was obtained but overestimated as expected. The total density of states was found and compared with experimental results. The electronic images show that the interactions between Mn, Ca and three O are stronger than that between La and O. The bonding of Mn-O is pd{sigma} bond

  5. Hernia Surgical Mesh Implants

    Science.gov (United States)

    ... Prosthetics Hernia Surgical Mesh Implants Hernia Surgical Mesh Implants Share Tweet Linkedin Pin it More sharing options ... majority of tissue used to produce these mesh implants are from a pig (porcine) or cow (bovine) ...

  6. Urogynecologic Surgical Mesh Implants

    Science.gov (United States)

    ... Prosthetics Urogynecologic Surgical Mesh Implants Urogynecologic Surgical Mesh Implants Share Tweet Linkedin Pin it More sharing options ... majority of tissue used to produce these mesh implants are from a pig (porcine) or cow (bovine). ...

  7. Degradation of implant materials

    CERN Document Server

    Eliaz, Noam

    2012-01-01

    This book surveys the degradation of implant materials, reviewing in detail such failure mechanisms as corrosion, fatigue and wear, along with monitoring techniques. Surveys common implant biomaterials, as well as procedures for implant retrieval and analysis.

  8. Robust rat pulmonary radioprotection by a lipophilic Mn N-alkylpyridylporphyrin, MnTnHex-2-PyP5+

    Directory of Open Access Journals (Sweden)

    Benjamin Gauter-Fleckenstein

    2014-01-01

    Full Text Available With the goal to enhance the distribution of cationic Mn porphyrins within mitochondria, the lipophilic Mn(IIImeso-tetrakis(N-n-hexylpyridinium-2-ylporphyrin, MnTnHex-2-PyP5+ has been synthesized and tested in several different model of diseases, where it shows remarkable efficacy at as low as 50 µg/kg single or multiple doses. Yet, in a rat lung radioprotection study, at higher 0.6–1 mg/kg doses, due to its high accumulation and micellar character, it became toxic. To avoid the toxicity, herein the pulmonary radioprotection of MnTnHex-2-PyP5+ was assessed at 50 µg/kg. Fischer rats were irradiated to their right hemithorax (28 Gy and treated with 0.05 mg/kg/day of MnTnHex-2-PyP5+ for 2 weeks by subcutaneously-implanted osmotic pumps, starting at 2 h post-radiation. The body weights and breathing frequencies were followed for 10 weeks post-radiation, when the histopathology and immunohistochemistry were assessed. Impact of MnTnHex-2-PyP5+ on macrophage recruitment (ED-1, DNA oxidative damage (8-OHdG, TGF-β1, VEGF(A and HIF-1α were measured. MnTnHex-2-PyP5+ significantly decreased radiation-induced lung histopathological (H&E staining and functional damage (breathing frequencies, suppressed oxidative stress directly (8-OHdG, or indirectly, affecting TGF-β1, VEGF (A and HIF-1α pathways. The magnitude of the therapeutic effects is similar to the effects demonstrated under same experimental conditions with 120-fold higher dose of ~5000-fold less lipophilic Mn(IIImeso-tetrakis(N-ethylpyridinium-2-ylporphyrin, MnTE-2-PyP5+.

  9. Operative considerations in implantation of the Perma-Flow graft.

    Science.gov (United States)

    Emery, R W; Joyce, L D; Arom, K V; King, R M; Nicoloff, D M

    1994-12-01

    The Perma-Flow coronary bypass graft (Possis Medical, Inc, Minneapolis, MN) currently is undergoing expanded clinical trial. From November 1992 through June 1994 we have used this artificial conduit in 8 patients without autologous alternatives. These cases allowed the establishment of a technical basis for successful implantation of this graft. All studied coronary anastomoses are patent.

  10. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2014-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  11. Implant marketing: cost effective implant dentistry.

    Science.gov (United States)

    Wohrle, P S; Levin, R P

    1996-01-01

    The application of the KAL-Technique to the field of implant dentistry allows both patients and dental practices to benefit. It is an exciting advance that decreases frustration and stress in providing implant procedures and lowers overall costs. Professionals using the KAL-Technique report significant predictability in achieving passive framework fit. They are also lowering overall cost of implant cases, which increases the number of patients who can accept implant treatment. It has been well established that the more individuals in a practice that receive implants, the more referrals a practice will gain. This is because implant patients find tremendous advances in the quality of life, and do not hesitate to tell others who can take advantage of this opportunity. Implant dentistry is one of the fastest growing fields in dentistry today. While some other areas of dentistry begin to decline in volume and need, implant dentistry provides the opportunity to keep practices strong and to insure long-term success.

  12. Immunohistochemical localization of integrin alpha V beta 3 and osteopontin suggests that they do not interact during embryo implantation in ruminants

    Directory of Open Access Journals (Sweden)

    MacLaren Leslie A

    2004-04-01

    Full Text Available Abstract Background It has been suggested that trophoblast attachment requires co-expression of integrin alpha V beta 3 and its ligand osteopontin at the fetal-maternal interface. Until now the expression patterns of integrin alpha V beta 3 and osteopontin in the pregnant bovine uterus were unknown. The objectives of this study were to localize integrin alpha V beta 3 and osteopontin in bovine and sheep endometrium during the periimplantation period and to compare the distribution patterns using antibodies that had not yet been tested in sheep. Methods Cell compartments within endometrial tissue sections were scored for immunohistochemical staining intensity and data were analyzed to determine the effects of day of pregnancy or cycle. Results In pregnant bovine endometrium, integrin alpha V beta 3 was detected in luminal epithelium, stroma, myometrium and smooth muscle. A strong band of immunoreactivity was observed in the subepithelial stroma of intercaruncular regions, but there was reduced reactivity in the caruncles and glands. Bovine trophoblast did not express integrin alpha V beta 3 at any stage of pregnancy. In ovine endometrium a different pattern of staining for integrin alpha V beta 3 was observed. Reactivity was not present in the luminal epithelium or trophoblast. There was strong staining of the deep glands and no reactivity in the superficial glands. Osteopontin distribution was similar for sheep and cattle. For both species, apical staining was present on the luminal epithelium and glands and on embryonic tissues. Conclusion In ruminants, integrin alpha V beta 3 and osteopontin do not co-localize at the fetal-maternal interface indicating that these proteins could not interact to facilitate embryo attachment as has been proposed in other species.

  13. X-ray Emission Spectroscopy of Biomimetic Mn Coordination Complexes.

    Science.gov (United States)

    Jensen, Scott C; Davis, Katherine M; Sullivan, Brendan; Hartzler, Daniel A; Seidler, Gerald T; Casa, Diego M; Kasman, Elina; Colmer, Hannah E; Massie, Allyssa A; Jackson, Timothy A; Pushkar, Yulia

    2017-06-15

    Understanding the function of Mn ions in biological and chemical redox catalysis requires precise knowledge of their electronic structure. X-ray emission spectroscopy (XES) is an emerging technique with a growing application to biological and biomimetic systems. Here, we report an improved, cost-effective spectrometer used to analyze two biomimetic coordination compounds, [Mn(IV)(OH)2(Me2EBC)](2+) and [Mn(IV)(O)(OH)(Me2EBC)](+), the second of which contains a key Mn(IV)═O structural fragment. Despite having the same formal oxidation state (Mn(IV)) and tetradentate ligands, XES spectra from these two compounds demonstrate different electronic structures. Experimental measurements and DFT calculations yield different localized spin densities for the two complexes resulting from Mn(IV)-OH conversion to Mn(IV)═O. The relevance of the observed spectroscopic changes is discussed for applications in analyzing complex biological systems such as photosystem II. A model of the S3 intermediate state of photosystem II containing a Mn(IV)═O fragment is compared to recent time-resolved X-ray diffraction data of the same state.

  14. Epitaxial Stabilization between Intermetallic and Carbide Domains in the Structures of Mn16SiC4 and Mn17Si2C4.

    Science.gov (United States)

    Fredrickson, Rie T; Guo, Yiming; Fredrickson, Daniel C

    2016-01-13

    The concept of frustration between competing geometrical or bonding motifs is frequently evoked in explaining complex phenomena in the structures and properties of materials. This idea is of particular importance for metallic systems, where frustration forms the basis for the design of metallic glasses, a source of diverse magnetic phenomena, and a rationale for the existence of intermetallics with giant unit cells containing thousands of atoms. Unlike soft materials, however, where conflicts can be synthetically encoded in the molecular structure, staging frustration in the metallic state is challenging due to the ease of macroscopic segregation of incompatible components. In this Article, we illustrate one approach for inducing the intergrowth of incompatible bonding motifs with the synthesis and characterization of two new intermetallic carbides: Mn16SiC4 (mC42) and Mn17Si2C4 (mP46). Similar to the phases Mn5SiC and Mn8Si2C in the Mn-Si-C system, these compounds appear as intergrowths of Mn3C and tetrahedrally close-packed (TCP) regions reminiscent of Mn-rich Mn-Si phases. The nearly complete spatial segregation of Mn-Si (intermetallic) and Mn-C (carbide) interactions in these structures can be understood from the differing geometrical requirements of C and Si. Rather than macroscopically separating into distinct phases, though, the two bonding types are tightly interwoven, with most Mn atoms being on the interfaces. DFT chemical pressure analysis reveals a driving force stabilizing these interfaces: the major local pressures acting between the Mn atoms in the Mn-Si and Mn-C systems are of opposite signs. Joining the intermetallic and carbide domains together then provides substantial relief to these local pressures, an effect we term epitaxial stabilization.

  15. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  16. [Bilateral cochlear implantation].

    Science.gov (United States)

    Kronenberg, Jona; Migirov, Lela; Taitelbaum-Swead, Rikey; Hildesheimer, Minka

    2010-06-01

    Cochlear implant surgery became the standard of care in hearing rehabilitation of patients with severe to profound sensorineural hearing loss. This procedure may alter the lives of children and adults enabling them to integrate with the hearing population. In the past, implantation was performed only in one ear, despite the fact that binaural hearing is superior to unilateral, especially in noisy conditions. Cochlear implantation may be performed sequentially or simultaneously. The "sensitive period" of time between hearing loss and implantation and between the two implantations, when performed sequentially, significantly influences the results. Shorter time spans between implantations improve the hearing results after implantation. Hearing success after implantation is highly dependent on the rehabilitation process which includes mapping, implant adjustments and hearing training. Bilateral cochlear implantation in children is recommended as the proposed procedure in spite of the additional financial burden.

  17. Inflammatory responses to Hydroxyapatite implants in middle ear in rats

    Institute of Scientific and Technical Information of China (English)

    YE Qing; JIANG Yi; WANG Xiao-yan; ZHENG Ke-fei

    2008-01-01

    Objective To study local inflammatory response after implantation of hydroxyapatite synthetic ossicular prosthesis. Methods Hydroxyapatite gantries were implanted in the bulla in 32 rats. Sham surgical procedures were performed in 10 rats as the control. Animals were sacrificed at 1 to 300 days after surgery. Bulla sections, stained with HE and Mallory's azan, were examined for numbers and percentages of various inflammatory cell types. Results Slightly more inflammatory reaction was seen in animals with the implant than in the controls, mostly during the early stage following the implantation procedure. Few inflammatory cells were observed at later times. There were satisfactory fibrosis in both implanted and control ears. Conclusion The results indicate that hydroxyapatite synthetic prosthesis is a biocompatible implantation material in the middle ear. Nonetheless, the presence of inflammatory reaction immediately following implantation implies that control of infection is important in the early times after the implantation procedure.

  18. Energy levels of 56Mn

    DEFF Research Database (Denmark)

    Van Assche, P. H. M.; Baader, H. A.; Koch, H. R.

    1971-01-01

    The low-energy spectrum of the 55Mn(n,γ)56 Mn reaction has been studied with a γ-diffraction spectrometer. These data allowed the construction of a level scheme for 56Mn with two previously unobserved doublets. High-energy γ-transitions to the low-energy states have been measured for different...

  19. Evaluation of manganese uptake and toxicity in mouse brain during continuous MnCl2 administration using osmotic pumps.

    Science.gov (United States)

    Sepúlveda, M R; Dresselaers, T; Vangheluwe, P; Everaerts, W; Himmelreich, U; Mata, A M; Wuytack, F

    2012-01-01

    Manganese is a vital element and cofactor of many key enzymes, but it is toxic at high levels, causing pronounced disturbances in the mammalian brain. Magnetic resonance imaging (MRI) studies using manganese ions as a paramagnetic contrast agent are often limited by the neurotoxicity of Mn(2+) . In this work, we have explored a new in vivo model to study Mn(2+) uptake, distribution and neurotoxicity in mice by subcutaneous implantation of mini-osmotic pumps delivering MnCl(2) continuously for 21 days. Fractionated injections can reduce the toxicity; however, constant administration at very low doses using osmotic pumps caused a substantial effect on the T(1) contrast in MRI while reducing toxicity. Manganese-enhanced MRI documented fast but reversible Mn(2+) deposition largely in glomerular and mitral cell layers of the olfactory bulb, in the CA3 area of the hippocampus, and in the gray matter of the cerebellum. Mn(2+) accumulated as early as the first days after implantation, with a fast dispersal 9 days after stopping a 12-days Mn(2+) exposure. Prominent Mn(2+) accumulation was also seen in salivary glands and in the endocrine thyroid and posterior pituitary gland. These structures with enhanced Mn(2+) accumulation correlated well with those showing high expression of the secretory pathway Ca(2+) /Mn(2+) -ATPase (SPCA1), i.e. a transporter that could take part in Mn(2+) detoxification. Our new experimental model for continuous low-dosage administration of Mn(2+) is an easy alternative for enhancing Mn(2+) -based contrast in MEMRI studies, and might provide insight into the etiology of neuropathologies resulting from chronic Mn(2+) exposure in vivo.

  20. The Enhancement of Mg Corrosion Resistance by Alloying Mn and Laser-Melting

    Directory of Open Access Journals (Sweden)

    Youwen Yang

    2016-03-01

    Full Text Available Mg has been considered a promising biomaterial for bone implants. However, the poor corrosion resistance has become its main undesirable property. In this study, both alloying Mn and laser-melting were applied to enhance the Mg corrosion resistance. The corrosion resistance, mechanical properties, and microstructure of rapid laser-melted Mg-xMn (x = 0–3 wt % alloys were investigated. The alloys were composed of dendrite grains, and the grains size decreased with increasing Mn. Moreover, Mn could dissolve and induce the crystal lattice distortion of the Mg matrix during the solidification process. Mn ranging from 0–2 wt % dissolved completely due to rapid laser solidification. As Mn contents further increased up to 3 wt %, a small amount of Mn was left undissolved. The compressive strength of Mg-Mn alloys increased first (up to 2 wt % and then decreased with increasing Mn, while the hardness increased continuously. The refinement of grains and the increase in corrosion potential both made contributions to the enhancement of Mg corrosion resistance.

  1. Peri-implant hastalıklar

    Directory of Open Access Journals (Sweden)

    M Selim Yavuz

    2011-11-01

    Full Text Available

    The treatment of partially or totally edentulous subjects with oral implants is a common procedure. Biological complications are occur around implants which are peri-implant mucositis and periimplantitis.

    Peri-implant mucositis is pathological condition which is normally localized in the soft tissues surrounding an oral implant. Peri-implantitis surrounding oral implants is an inflammatory process affecting the soft and hard tissues resulting in rapid loss of supporting bone associated with bleeding and suppuration. The diagnosis of peri-implant diseases is usually established by assessing probing depth, gingival index, bleeding on probing and radiographic bone resorption examinations. The etiopathogenesis of peri-implant diseases is related to the periimplant environment and to the soft tissues/implant interface, to patient-related factors (smoke, systemic diseases, plaque control and to host-parasite equilibrium.

    Peri-implant diseases can be controlled successfully by providing mechanical, antiseptic, antibiotic and surgical supportive therapy, individually or combined.

     

    ÖZET

    Tam veya kısmi dişsiz hastaların tedavisinde yaygın prosedürlerden biride oral implantlardır. İmplantların etrafında peri-implant mukositis ve peri-implantitis diye biyolojik komplikasyonlar meydana gelir. Peri-implant mukositis bir oral implantın etrafındaki normalde yumuşak dokuda lokalize patolojik bir durumdur. Oral implantların çevresindeki peri-implantitis süpürasyon ve kanama ile ilişkili destek kemiğin hızlı kaybı ile sonuçlanan, sert ve yumuşak dokuları etkileyen inflamatuar bir süreçtir.

    Peri-implant hastalıkların teşhisi genellikle sondalama cep derinliği, gingival indeks, sondalamada kanama ve radyografik kemik rezorbsiyon muayenesi ile kanıtlanır. Peri-implant hastalıkların etiyopatogenezi, peri-implant çevre ve yumuşak doku-implant yüzleşmesi, hasta ile ili

  2. Mn porphyrins as novel molecular magnetic resonance imaging contrast agents.

    Science.gov (United States)

    Mouraviev, Vladimir; Venkatraman, Talaignair N; Tovmasyan, Artak; Kimura, Masaki; Tsivian, Matvey; Mouravieva, Vladimira; Polascik, Tom J; Wang, Haichen; Amrhein, Timothy J; Batinic-Haberle, Ines; Lascola, Christopher

    2012-11-01

    In this study, we investigated the potential of a new class of therapeutic Mn porphyrins as molecular MRI probes for prostate cancer imaging. Two compounds of different bioavailibility were investigated: Mn(III) meso-tetrakis(N-ethylpyridinium-2-yl)porphyrin (MnTE-2-PyP(5+)) and Mn(III) meso-tetrakis(N-n-hexylpyridinium-2-yl)porphyrin (MnTnHex-2-PyP(5+)). These compounds have previously been shown to have adjunctive antineoplastic activity through their actions as powerful superoxide dismutase mimics, peroxynitrite scavengers, and modulators of cellular redox-based signaling pathways. Strong paramagnetic MRI contrast properties and affinity for cancer cells suggest their potential application as novel diagnostic imaging agents. MRI experiments were performed at 7.0T on a Bruker Biospec horizontal bore scanner. All in-vivo experiments were performed on 12 C57 black mice implanted with RM-9 prostate cancer cells on the hind limb. Two mg/kg of MnTnHex-2-PyP(5+) (n=6) and 8 mg/kg MnTE-2-PyP(5+) (n=6) were administered intraperitoneally 90 minutes before imaging. All the images were collected using a volume coil and processed using Paravision 4.0. Phantom studies reveal remarkably high T1 relaxivity changes for both metalloporphyrins, which are twofold to threefold higher than commercially available gadolinium chelates. Observable detection limits using conventional T1-weighted MRI are in the low micromolar range for both compounds. In vivo, MR relaxation changes in prostate tumor xenografts were readily observed after a single injection of either MnTE-2-PyP(5+)or MnTnHex-2-PyP(5+), with tumor contrast to background ratio greatest after MnTE-2-PyP(5+) administration. After a single dose of MnTE-2-PyP(5+), contrast changes in prostate tumors are up to sixfold greater than in surrounding, noncancerous tissues, suggesting the potential use of this metalloporphyrin as a novel diagnostic probe for detecting prostate malignancy using MRI.

  3. Early dental implant failure in patient associated with oral bisphosphonates

    Directory of Open Access Journals (Sweden)

    Ridhimaa Gupta

    2012-01-01

    Full Text Available Oral bisphosphonates are routinely prescribed to post menopausal women. These have shown to increase the risk of osteonecrosis. However, this action may be augmented by local factors. A case report is presented showing an early implant failure in a patient taking oral bisphosphonates. Two implants were placed in left maxillary incisor area. Central incisor was associated with a previous endodontic failure and extraction. Lateral incisor was avulsed 3 years back. After 4 weeks of an implant placement, necrotic bone was evident along with the failing implant in central incisor area. This case report emphasizes on the incidence and an increased risk of implant failure in patients taking oral bisphosphonates.

  4. Theory of ferromagnetic (III,Mn)V semiconductors

    Science.gov (United States)

    Jungwirth, T.; Sinova, Jairo; Mašek, J.; Kučera, J.; MacDonald, A. H.

    2006-07-01

    The body of research on (III,Mn)V diluted magnetic semiconductors (DMSs) initiated during the 1990s has concentrated on three major fronts: (i) the microscopic origins and fundamental physics of the ferromagnetism that occurs in these systems, (ii) the materials science of growth and defects, and (iii) the development of spintronic devices with new functionalities. This article reviews the current status of the field, concentrating on the first two, more mature research directions. From the fundamental point of view, (Ga,Mn)As and several other (III,Mn)V DMSs are now regarded as textbook examples of a rare class of robust ferromagnets with dilute magnetic moments coupled by delocalized charge carriers. Both local moments and itinerant holes are provided by Mn, which makes the systems particularly favorable for realizing this unusual ordered state. Advances in growth and postgrowth-treatment techniques have played a central role in the field, often pushing the limits of dilute Mn-moment densities and the uniformity and purity of materials far beyond those allowed by equilibrium thermodynamics. In (III,Mn)V compounds, material quality and magnetic properties are intimately connected. This review focuses on the theoretical understanding of the origins of ferromagnetism and basic structural, magnetic, magnetotransport, and magneto-optical characteristics of simple (III,Mn)V epilayers, with the main emphasis on (Ga,Mn)As. Conclusions are arrived at based on an extensive literature covering results of complementary ab initio and effective Hamiltonian computational techniques, and on comparisons between theory and experiment. The applicability of ferromagnetic semiconductors in microelectronic technologies requires increasing Curie temperatures from the current record of 173K in (Ga,Mn)As epilayers to above room temperature. The issue of whether or not this is a realistic expectation for (III,Mn)V DMSs is a central question in the field and motivates many of the analyses

  5. Nanoscale characterization of bone-implant interface and biomechanical modulation of bone ingrowth

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Paul A. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States)]. E-mail: pclark4@gmail.com; Clark, Andrew M. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States); Rodriguez, Anthony [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States); Hussain, Mohammad A. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States); Mao, Jeremy J. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States)]. E-mail: jmao2@uic.edu

    2007-04-15

    Bone-implant interface is characterized by an array of cells and macromolecules. This study investigated the nanomechancial properties of bone-implant interface using atomic force microscopy in vitro, and the mechanical modulation of implant bone ingrowth in vivo using bone histomorphometry. Upon harvest of screw-type titanium implants placed in vivo in the rabbit maxilla and proximal femur for 4 weeks, nanoindentation was performed in the bone-implant interface at 60-{mu}m intervals radially from the implant surface. The average Young's Moduli (E) of the maxillary bone-implant interface was 1.13 {+-} 0.27 MPa, lacking significant differences at all intervals. In contrast, an increasing gradient of E was observed radially from the femur bone-implant interface: 0.87 {+-} 0.25 MPa to 2.24 {+-} 0.69 MPa, representing significant differences among several 60-{mu}m intervals. In a separate experiment, bone healing was allowed for 6 weeks for proximal femur implants. The right femoral implant received axial cyclic loading at 200 mN and 1 Hz for 10 min/d over 12 days, whereas the left femoral implant served as control. Cyclic loading induced significantly higher bone volume, osteoblast numbers per endocortical bone surface, mineral apposition rate, and bone formation rate than controls. These data demonstrate nanoscale and microscale characterizations of bone-implant interface, and mechanical modulation of bone ingrowth surrounding titanium implants.

  6. Biofilm and dental implant: The microbial link

    Directory of Open Access Journals (Sweden)

    Sangeeta Dhir

    2013-01-01

    Full Text Available Mouth provides a congenial environment for the growth of the microorganisms as compared to any other part of the human body by exhibiting an ideal nonshedding surface. Dental plaque happens to be a diverse community of the microorganisms found on the tooth surface. Periodontal disease and the peri-implant disease are specific infections that are originating from these resident microbial species when the balance between the host and the microbial pathogenicity gets disrupted. This review discusses the biofilms in relation to the peri-implant region, factors affecting its presence, and the associated treatment to manage this complex microbial colony. Search Methodology: Electronic search of the medline was done with the search words: Implants and biofilms/dental biofilm formation/microbiology at implant abutment interface/surface free energy/roughness and implant, periimplantitis/local drug delivery and dental implant. Hand search across the journals - clinical oral implant research, implant dentistry, journal of dental research, international journal of oral implantology, journal of prosthetic dentistry, perioodntology 2000, journal of periodontology were performed. The articles included in the review comprised of in vivo studies, in vivo (animal and human studies, abstracts, review articles.

  7. Biofilm and dental implant: The microbial link

    Science.gov (United States)

    Dhir, Sangeeta

    2013-01-01

    Mouth provides a congenial environment for the growth of the microorganisms as compared to any other part of the human body by exhibiting an ideal nonshedding surface. Dental plaque happens to be a diverse community of the microorganisms found on the tooth surface. Periodontal disease and the peri-implant disease are specific infections that are originating from these resident microbial species when the balance between the host and the microbial pathogenicity gets disrupted. This review discusses the biofilms in relation to the peri-implant region, factors affecting its presence, and the associated treatment to manage this complex microbial colony. Search Methodology: Electronic search of the medline was done with the search words: Implants and biofilms/dental biofilm formation/microbiology at implant abutment interface/surface free energy/roughness and implant, periimplantitis/local drug delivery and dental implant. Hand search across the journals – clinical oral implant research, implant dentistry, journal of dental research, international journal of oral implantology, journal of prosthetic dentistry, perioodntology 2000, journal of periodontology were performed. The articles included in the review comprised of in vivo studies, in vivo (animal and human) studies, abstracts, review articles. PMID:23633764

  8. Ultrasound in Local Soft Tissue Lesions After Orthopaedic Implant Surgery%骨科内植物植入术后局部软组织病变的超声应用价值

    Institute of Scientific and Technical Information of China (English)

    袁宇; 高金妹; 郭林; 谷超

    2015-01-01

    目的:骨科手术后,进行CT或MRI检查时金属内植物的伪影常严重影响图像质量,局部软组织病变显示受限,本研究旨在探讨金属内植物植入术后超声检查对局部软组织病变的应用价值。资料与方法对70例各种骨科金属内植物植入术后手术区域进行超声检查,记录包括病灶的形态、大小、内部回声、边缘情况、有无包膜及钙化、血流情况等声像图特征。回顾性分析纳入患者的临床资料以及X线平片、CT、MRI检查的影像学资料,比较超声检查与其他影像检查的敏感度。结果超声检查诊断血肿20例,脓肿5例,假性动脉瘤5例,骨化性肌炎3例,骨肿瘤复发15例,周围神经损伤12例。超声诊断对内植物植入术后周围软组织病变的敏感度、特异度、准确度分别为89.4%、75.0%、88.6%,明显高于X线、CT、MRI检查(χ2=78.642、46.596、61.371,P<0.01)。血肿为边界清楚、内部回声均匀的低至无回声区。脓肿为囊实性混合回声,囊腔内脓液点状回声可浮动,彩色多普勒显像示中心区无血流信号。假性动脉瘤表现为动脉周围囊性包块,囊内血流旋转流动,颈部可探及典型的双期双向频谱信号。骨化性肌炎表现为肌肉内出现不规则的强回声伴声影。骨肿瘤复发时可见低回声软组织肿块,肿块内多可探及血流信号,出现虫蚀样骨质破坏。外周神经损伤时可致神经肿胀增粗、回声减低。结论超声检查在对金属内植物植入术后的软组织等结构观察中有较高的准确性,可作为首选方法。%PurposeArtifacts of metal implantation severely affect image quality of CT or MRI examination, which restricts the display of local soft tissue lesions after orthopaedic surgery. This study aims to explore the application value of ultrasound examination in local soft tissue lesions after metal implant surgery.Materials and Methods

  9. X-ray absorption near edge spectroscopy at the Mn K-edge in highly homogeneous GaMnN diluted magnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Sancho-Juan, O.; Cantarero, A.; Garro, N.; Cros, A. [Materials Science Institute, University of Valencia, PO Box 22085, 46071 Valencia (Spain); Martinez-Criado, G.; Salome, M.; Susini, J. [ESRF, Polygone Scientifique Louis Neel, 6 rue Jules Horowitz, 38000 Grenoble (France); Olguin, D. [Dept. de Fisica, CINVESTAV-IPN, 07300 Mexico D.F. (Mexico); Dhar, S.; Ploog, K. [Paul Drude Institute, Hausvogteiplatz 5-7, 10117 Berlin (Germany)

    2006-06-15

    We have studied by X-ray absorption spectroscopy the local environment of Mn in highly homogeneous Ga{sub 1-x}Mn{sub x}N (0.06Mn K-edges. In this report, we focus our attention to the X-ray absorption near edge spectroscopy (XANES) results. The comparison of the XANES spectra corresponding to the Ga and Mn edges indicates that Mn is substitutional to Ga in all samples studied. The XANES spectra measured at the Mn absorption edge shows in the near-edge region a double peak and a shoulder below the absorption edge and the main absorption peak after the edge, separated around 15 eV above the pre-edge structure. We have compared the position of the edge with that of MnO (Mn{sup 2+}) and Mn{sub 2}O{sub 3} (Mn{sup 3+}). All samples studied present the same Mn oxidation state, 2{sup +}. In order to interprete the near-edge structure, we have performed ab initio calculations with a 2 x 2 x 1supercell ({proportional_to}6% Mn) using the full potential linear augmented plane wave method as implemented in the Wien2k code. The calculations show the appearance of Mn anti-bonding t{sub 2g} bands, which are responsible for the pre-edge absorption. The shoulder and main absorption peaks are due to transitions from the valence band 1s-states of Mn to the p-contributions of the conduction bands. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Implant success!!!.....simplified

    Directory of Open Access Journals (Sweden)

    Luthra Kaushal

    2009-01-01

    Full Text Available The endeavor towards life-like restoration has helped nurture new vistas in the art and science of implant dentistry. The protocol of "restoration-driven implant placement" ensures that the implant is an apical extension of the ideal future restoration and not the opposite. Meticulous pre-implant evaluation of soft and hard tissues, diagnostic cast and use of aesthetic wax-up and radiographic template combined with surgical template can simplify the intricate roadmap for appropriate implant treatment. By applying the harmony of artistic skill, scientific knowledge and clinical expertise, we can simply master the outstanding implant success in requisites of aesthetics, phonetics and function.

  11. Breast Implants: Saline vs. Silicone

    Science.gov (United States)

    ... differ in material and consistency, however. Saline breast implants Saline implants are filled with sterile salt water. ... of any age for breast reconstruction. Silicone breast implants Silicone implants are pre-filled with silicone gel — ...

  12. Mn bioavailability by polarized Caco-2 cells: comparison between Mn gluconate and Mn oxyprolinate

    Directory of Open Access Journals (Sweden)

    Fulgenzi Alessandro

    2011-07-01

    Full Text Available Abstract Background Micronutrient inadequate intake is responsible of pathological deficiencies and there is a need of assessing the effectiveness of metal supplementation, frequently proposed to rebalance poor diets. Manganese (Mn is present in many enzymatic intracellular systems crucial for the regulation of cell metabolism, and is contained in commercially available metal supplements. Methods We compared the effects of two different commercial Mn forms, gluconate (MnGluc and oxyprolinate (MnOxP. For this purpose we used the polarized Caco-2 cells cultured on transwell filters, an established in vitro model of intestinal epithelium. Since micronutrient deficiency may accelerate mitochondrial efficiency, the mitochondrial response of these cells, in the presence of MnGluc and MnOxP, by microscopy methods and by ATP luminescence assay was used. Results In the presence of both MnOxP and MnGluc a sustained mitochondrial activity was shown by mitoTraker labeling (indicative of mitochondrial respiration, but ATP intracellular content remained comparable to untreated cells only in the presence of MnOxP. In addition MnOxP transiently up-regulated the antioxidant enzyme Mn superoxide dismutase more efficiently than MnGluc. Both metal treatments preserved NADH and βNADPH diaphorase oxidative activity, avoided mitochondrial dysfunction, as assessed by the absence of a sustained phosphoERK activation, and were able to maintain cell viability. Conclusions Collectively, our data indicate that MnOxP and MnGluc, and primarily the former, produce a moderate and safe modification of Caco-2 cell metabolism, by activating positive enzymatic mechanisms, thus could contribute to long-term maintenance of cell homeostasis.

  13. Spin polarization and exchange coupling of Cu and Mn atoms in paramagnetic CuMn diluted alloys induced by a Co layer

    Science.gov (United States)

    Abes, M.; Atkinson, D.; Tanner, B. K.; Charlton, T. R.; Langridge, Sean; Hase, T. P. A.; Ali, M.; Marrows, C. H.; Hickey, B. J.; Neudert, A.; Hicken, R. J.; Arena, D.; Wilkins, S. B.; Mirone, A.; Lebègue, S.

    2010-11-01

    Using the surface, interface, and element specificity of x-ray resonant magnetic scattering in combination with x-ray magnetic circular dichroism, we have spatially resolved the magnetic spin polarization, and the associated interface proximity effect, in a Mn-based high-susceptibility material close to a ferromagnetic Co layer. We have measured the magnetic polarization of Mn and Cu3d electrons in paramagnetic CuMn alloy layers in [Co/Cu(x)/CuMn/Cu(x)]20 multilayer samples with varying copper layer thicknesses from x=0 to 25Å . The size of the Mn and CuL2,3 edge dichroism shows a decrease in the Mn-induced polarization for increasing copper thickness indicating the dominant interfacial nature of the Cu and Mn spin polarization. The Mn polarization is much higher than that of Cu. Evidently, the Mn moment is a useful probe of the local spin density. Mn atoms appear to be coupled antiferromagnetically with the Co layer below x=10Å and ferromagnetically coupled above. In contrast, the interfacial Cu atoms remain ferromagnetically aligned to the Co layer for all thicknesses studied.

  14. Urinary incontinence - collagen implants

    Science.gov (United States)

    ... gov/ency/article/007373.htm Urinary incontinence - injectable implant To use the sharing features on this page, please enable JavaScript. Injectable implants are injections of material into the urethra to ...

  15. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  16. About Implantable Contraception

    Science.gov (United States)

    ... a tube was inserted, and get a new contraceptive implant on schedule or switch to another method of ... continue Possible Side Effects Young women who get contraceptive implants might notice such side effects as: irregular or ...

  17. Breast Reconstruction with Implants

    Science.gov (United States)

    Breast reconstruction with implants Overview By Mayo Clinic Staff Breast reconstruction is a surgical procedure that restores shape to ... treat or prevent breast cancer. One type of breast reconstruction uses breast implants — silicone devices filled with silicone ...

  18. Raman Submicron Spatial Mapping of Individual Mn-doped ZnO Nanorods.

    Science.gov (United States)

    Strelchuk, V; Kolomys, O; Rarata, S; Lytvyn, P; Khyzhun, O; Chey, Chan Oeurn; Nur, Omer; Willander, Magnus

    2017-12-01

    ZnO nanorods (NRs) arrays doped with a large concentration of Mn synthesized by aqueous chemical growth and were characterized by SEM, photoluminescence, Raman scattering, magnetic force microscopy (MFM). By comparison of spectra taken on pure and Mn-doped ZnO NRs, a few new Raman impurity-related phonon modes, resulting from the presence of Mn in the investigated samples. We also present a vibrational and magnetic characterization of individual lying nanorods using Raman and MFM imaging. Confocal scanning micro-Raman mapping of the spatial distribution of intensity and frequency of phonon modes in single Mn-doped ZnO NRs nanorods is presented and analyzed for the first time. Mn-related local vibrational modes are also registered in Raman spectra of the single nanorod, confirming the incorporation of Mn into the ZnO host matrix. At higher Mn concentration the structural transformation toward the spinel phase ZnMn2O4 and Mn3O4 is observed mainly in 2D bottom layers. MFM images of Mn-doped ZnO NR arrays and single nanorod were studied in nanoscale at room temperature and demonstrate magnetic behavior. The circular domain magnetic pattern on top of single nanorod originated to superposition of some separate domains inside rod. This demonstrates that long-range ferromagnetic order is present at room temperature. Aligned Mn-doped ZnO NRs demonstrates that long-range ferromagnetic order and may be applied to future spintronic applications.

  19. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  20. Implantable Heart Aid

    Science.gov (United States)

    1984-01-01

    CPI's human-implantable automatic implantable defibrillator (AID) is a heart assist system, derived from NASA's space circuitry technology, that can prevent erratic heart action known as arrhythmias. Implanted AID, consisting of microcomputer power source and two electrodes for sensing heart activity, recognizes onset of ventricular fibrillation (VF) and delivers corrective electrical countershock to restore rhythmic heartbeat.

  1. Curie temperature of GaMnN and GaMnAs from LDA-SIC electronic structure calculations

    Energy Technology Data Exchange (ETDEWEB)

    Toyoda, Masayuki; Sato, Kazunori; Katayama-Yoshida, Hiroshi [Department of Computational Nanomaterials Design, Institute of Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Akai, Hisazumi [Department of Physics, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan)

    2006-07-01

    We present the electronic structures, magnetic exchange interactions and Curie temperature (T{sub C}) of GaMnN and GaMnAs calculated by self-interaction-corrected local-density approximation (LDA-SIC). In GaMnAs, the LDA-SIC results of T{sub C} do not differ so much from the LDA results. Both the LDA and LDA-SIC values are in a good agreement with the experimental data. In GaMnN, on the other hand, the ferromagnetic exchange interactions are enhanced due to the suppression of antiferromagnetic super-exchange interaction, resulting in T{sub C} higher than the LDA results. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. A Mn-54 Radiotracer Study of Mn Isotope Solid-Liquid Exchange during Reductive Transformation of Vernadite (δ-MnO₂) by Aqueous Mn(II)

    Energy Technology Data Exchange (ETDEWEB)

    Elzinga, Evert J.; Kustka, Adam B. [Rutgers

    2015-04-09

    We employed Mn-54 radiotracers to characterize the extent and dynamics of Mn atom exchange between aqueous Mn(II) and vernadite (δ-Mn(IV)O2) at pH 7.5 under anoxic conditions. Exchange of Mn atoms between the solid and liquid phase is rapid, reaching dynamic equilibrium in 2–4 days. We propose that during the initial stages of reaction, Mn atom exchange occurs through consecutive comproportionation-disproportionation reactions where interfacial electron transfer from adsorbed Mn(II) to lattice Mn(IV) generates labile Mn(III) cations that rapidly disproportionate to reform aqueous Mn(II) and solid-phase Mn(IV). Following nucleation of Mn(III)OOH phases, additional exchange likely occurs through electron transfer from aqueous Mn(II) to solid-phase Mn(III). Our results provide evidence for the fast and extensive production of transient Mn(III) species at the vernadite surface upon contact of this substrate with dissolved Mn(II). We further show that HEPES buffer is a reductant of lattice Mn(IV) in the vernadite structure in our experiments. The methods and results presented here introduce application of Mn-54 tracers as a facile tool to further investigate the formation kinetics of labile Mn(III) surface species and their impacts on Mn-oxide structure and reactivity over a range of environmentally relevant geochemical conditions.

  3. On the rich magnetic phase diagram of (Ni, Co)-Mn-Sn Heusler alloys

    Science.gov (United States)

    Grünebohm, A.; Herper, H. C.; Entel, P.

    2016-10-01

    We put a spotlight on the exceptional magnetic properties of the metamagnetic Heusler alloy (Ni, Co)-Mn-Sn by means of first principles simulations. In the energy landscape we find a multitude of local minima, which belong to different ferrimagnetic states and are close in total magnetization and energy. All these magnetic states correspond to the local high spin state of the Mn atoms with different spin alignments and are related to the magnetic properties of Mn. Compared to pure Mn, the magneto-volume coupling is reduced by Ni, Co and Sn atoms in the lattice and no local low-spin Mn states appear. For the cubic phase we find a ferromagnetic ground state whereas the global energy minimum is a tetragonal state with a complicated spin structure and vanishing magnetization which so far has been overlooked in simulations.

  4. Influence of magnetic on ferroelectric ordering in LuMnO3

    NARCIS (Netherlands)

    Van Aken, BB; Palstra, TTM

    2004-01-01

    We have studied the influence of antiferromagnetic ordering on the local dielectric moments of the MnO5 and LuO7 polyhedra by measuring neutron powder-diffraction patterns of LuMnO3 at temperatures near T-N. We show that the coupling is weak, because the magnetic exchange coupling is predominantly i

  5. COCHLEAR IMPLANTATION: MY EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Shankar

    2015-12-01

    Full Text Available Cochlear implant is a small, surgically implanted complex electronic device that can help to provide a sense of sound to a person with severe to profound sensorineural hearing loss. This type of hearing loss, typically involves damage to hair cells in the cochlea, as a result sound cannot reach the auditory nerve which usually receives information from hair cells. A cochlear implant skips the damaged hair cells and to stimulate the auditory nerve directly. An implant does not restore normal hearing, instead it can give a deaf person a useful representation of sounds in the environment and help him or her to understand speech. I am here presenting this article in relation to the indications, intraoperative and postoperative complications of cochlear implantation in our institute since January 2013. Children who receive implants at earlier age, outperform their peers who are implanted at a later age. This is reflected in all the areas of speech and language development.

  6. Implantes transcigomáticos Traszygomatic implants

    OpenAIRE

    B. Fernández Ateca; M. Colorado Bonnin; C. Gay Escoda

    2004-01-01

    Los implantes cigomáticos, originariamente diseñados por Branemark en 1989, son implantes de cabeza en 45 grados, de 4'5 milímetros de diámetro en su parte más ancha, y que pueden medir entre 30 y 50 milímetros de longitud. Se insertan desde la parte palatina del proceso alveolar, siguiendo la cresta cigomática-alveolar hasta anclarse en el cuerpo del malar, y en el caso de pacientes maxilectomizados, entrando directamente en el cuerpo del malar. Estos implantes ofrecen una alternativa más al...

  7. Anticancer therapeutic potential of Mn porphyrin/ascorbate system.

    Science.gov (United States)

    Tovmasyan, Artak; Sampaio, Romulo S; Boss, Mary-Keara; Bueno-Janice, Jacqueline C; Bader, Bader H; Thomas, Milini; Reboucas, Julio S; Orr, Michael; Chandler, Joshua D; Go, Young-Mi; Jones, Dean P; Venkatraman, Talaignair N; Haberle, Sinisa; Kyui, Natalia; Lascola, Christopher D; Dewhirst, Mark W; Spasojevic, Ivan; Benov, Ludmil; Batinic-Haberle, Ines

    2015-12-01

    Ascorbate (Asc) as a single agent suppressed growth of several tumor cell lines in a mouse model. It has been tested in a Phase I Clinical Trial on pancreatic cancer patients where it exhibited no toxicity to normal tissue yet was of only marginal efficacy. The mechanism of its anticancer effect was attributed to the production of tumoricidal hydrogen peroxide (H2O2) during ascorbate oxidation catalyzed by endogenous metalloproteins. The amount of H2O2 could be maximized with exogenous catalyst that has optimized properties for such function and is localized within tumor. Herein we studied 14 Mn porphyrins (MnPs) which differ vastly with regards to their redox properties, charge, size/bulkiness and lipophilicity. Such properties affect the in vitro and in vivo ability of MnPs (i) to catalyze ascorbate oxidation resulting in the production of H2O2; (ii) to subsequently employ H2O2 in the catalysis of signaling proteins oxidations affecting cellular survival pathways; and (iii) to accumulate at site(s) of interest. The metal-centered reduction potential of MnPs studied, E1/2 of Mn(III)P/Mn(II)P redox couple, ranged from -200 to +350 mV vs NHE. Anionic and cationic, hydrophilic and lipophilic as well as short- and long-chained and bulky compounds were explored. Their ability to catalyze ascorbate oxidation, and in turn cytotoxic H2O2 production, was explored via spectrophotometric and electrochemical means. Bell-shape structure-activity relationship (SAR) was found between the initial rate for the catalysis of ascorbate oxidation, vo(Asc)ox and E1/2, identifying cationic Mn(III) N-substituted pyridylporphyrins with E1/2>0 mV vs NHE as efficient catalysts for ascorbate oxidation. The anticancer potential of MnPs/Asc system was subsequently tested in cellular (human MCF-7, MDA-MB-231 and mouse 4T1) and animal models of breast cancer. At the concentrations where ascorbate (1mM) and MnPs (1 or 5 µM) alone did not trigger any alteration in cell viability, combined

  8. Amorphous clusters in Co implanted ZnO induced by boron pre-implantation

    Energy Technology Data Exchange (ETDEWEB)

    Potzger, K.; Shalimov, A.; Zhou, S.; Schmidt, H.; Mucklich, A.; Helm, M.; Fassbender, J.; Liberati, M.; Arenholz, E.

    2009-02-09

    We demonstrate the formation of superparamagnetic/ferromagnetic regions within ZnO(0001) single crystals sequently implanted with B and Co. While the pre-implantation with B plays a minor role for the electrical transport properties, its presence leads to the formation of amorphous phases. Moreover, B acts strongly reducing on the implanted Co. Thus, the origin of the ferromagnetic ordering in local clusters with large Co concentration is itinerant d-electrons as in the case of metallic Co. The metallic amorphous phases are non-detectable by common X-ray diffraction.

  9. Optical properties of ZnS:Mn nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, F.; En Naciri, A. [Universite Paul Verlaine-Metz, Laboratoire LPMD, 1 Bd Arago, 57078 Metz (France); Grob, J.J. [InESS, 23 rue du Loess-B20, 67037 Strasbourg Cedex 2 (France)

    2010-02-15

    The optical properties of Mn-doped zinc sulfide (ZnS) nanocrystals embedded in SiO{sub 2} matrix are studied by spectroscopic ellipsometry (SE). The crystals are obtained by sequential multi-energy ion implantation of Zn, S, and Mn into a silica layer grown on Si(111) followed by a subsequent annealing for 30 min at 900 C. The formation of the nanocrystals is evidenced by transmission electron microscopy. The application of a critical-point based model for the analysis of the SE data yields die dielectric function (DF) between 0.6 and 6.5 eV. A pronounced shift of the absorption edge towards higher energies is detected for the nanocrystals In comparison to bulk ZnS (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Use of alendronate in peri-implant defect regeneration.

    Science.gov (United States)

    Meraw, S J; Reeve, C M; Wollan, P C

    1999-02-01

    Previous studies have demonstrated an increase in bone mass and density with use of systemic alendronate sodium. This agent acts as an inhibitor of osteoclast activity, and is thought to result in more net osteoblastic activity. The objective of this study was to determine the effects of locally applied alendronate sodium on guided bone regeneration around dental implants. Six adult mongrel dogs were divided into 2 groups: one group received alendronate-coated dental implants, and the other group served as control. Two types of dental implants were used in each dog: hydroxyapatite (HA)-coated and titanium machine-polished (TMP), for a total of 4 groups. Dental implants were placed immediately after extraction of the right and left second, third, and fourth mandibular premolars; a resorbable collagen membrane was secured over the implants and defects; and the flaps were closed primarily. Fluorescent labels were administered intravenously on days 0, 6, 12, and 22 to measure bone formation rate. Dogs were sacrificed on day 28. The specimens were sectioned and mounted, and bone formation rate was recorded with a computerized microscopic digitizer. Specimens were stained with Stevenel's blue and van Gieson's picric fuchsin. Bone-to-implant contact was recorded with a computerized microscopic digitizer. The results indicated a significant effect of locally applied alendronate (P < 0.0001) with both types of implants (HA and TMP), as well as the HA coating (P< 0.02) on increased bone formation rate. Additionally, alendronate had a significant effect on bone-to-implant contact, with an increase in the TMP model (P < 0.0001) and a decrease in the HA model (P < 0.0001 ). HA coating also had a significant effect on increasing bone-to-implant contact (P < 0.04). The results indicate that alendronate increases early bone formation rate around dental implants. Additionally, the local application as described resulted in greater bone-to-implant contact with TMP implants.

  11. Magnetic anisotropies of (Ga,Mn)As films and nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Frank

    2011-02-02

    In this work the magnetic anisotropies of the diluted magnetic semiconductor (Ga,Mn)As were investigated experimentally. (Ga,Mn)As films show a superposition of various magnetic anisotropies which depend sensitively on various parameters such as temperature, carrier concentration or lattice strain. However, the anisotropies of lithographically prepared (Ga,Mn)As elements differ significantly from an unpatterned (Ga,Mn)As film. In stripe-shaped structures this behaviour is caused by anisotropic relaxation of the compressive lattice strain. In order to determine the magnetic anisotropies of individual (Ga,Mn)As nanostructures a combination of ferromagnetic resonance and time-resolved scanning Kerr microscopy was employed in this thesis. In addition, local changes of the magnetic anisotropy in circular and rectangular structures were visualized by making use of spatially resolved measurements. Finally, also the influence of the laterally inhomogeneous magnetic anisotropies on the static magnetic properties, such as coercive fields, was investigated employing spatially resolved static MOKE measurements on individual (Ga,Mn)As elements. (orig.)

  12. Investigation of Room temperature Ferromagnetism in Mn doped Ge

    Science.gov (United States)

    Colakerol Arslan, Leyla; Toydemir, Burcu; Onel, Aykut Can; Ertas, Merve; Doganay, Hatice; Gebze Inst of Tech Collaboration; Research Center Julich Collaboration

    2014-03-01

    We present a systematic investigation of structural, magnetic and electronic properties of MnxGe1 -x single crystals. MnxGe1-x films were grown by sequential deposition of Ge and Mn by molecular-beam epitaxy at low substrate temperatures in order to avoid precipitation of ferromagnetic Ge-Mn intermetallic compounds. Reflected high energy electron diffraction and x-ray diffraction observations revealed that films are epitaxially grown on Si (001) substrates from the initial stage without any other phase formation. Magnetic measurements carried out using a physical property measurement system showed that all samples exhibited ferromagnetism at room temperature. Electron spin resonance indicates the presence of magnetically ordered localized spins of divalent Mn ions. X-ray absorption measurements at the Mn L-edge confirm significant substitutional doping of Mn into Ge-sites. The ferromagnetism was mainly induced by Mn substitution for Ge site, and indirect exchange interaction of these magnetic ions with the intrinsic charge carriers is the origin of ferromagnetism. The magnetic interactions were better understood by codoping with nonmagnetic impurities. This work was supported by Marie-Curie Reintegration Grant (PIRG08-GA-2010-276973).

  13. Implantes transcigomáticos Traszygomatic implants

    Directory of Open Access Journals (Sweden)

    B. Fernández Ateca

    2004-12-01

    Full Text Available Los implantes cigomáticos, originariamente diseñados por Branemark en 1989, son implantes de cabeza en 45 grados, de 4'5 milímetros de diámetro en su parte más ancha, y que pueden medir entre 30 y 50 milímetros de longitud. Se insertan desde la parte palatina del proceso alveolar, siguiendo la cresta cigomática-alveolar hasta anclarse en el cuerpo del malar, y en el caso de pacientes maxilectomizados, entrando directamente en el cuerpo del malar. Estos implantes ofrecen una alternativa más al cirujano en el momento de planificar un tratamiento protésico-rehabilitador implantosoportado. Sobretodo, en aquellos pacientes con un maxilar superior atrófico en el que no se pueden realizar injertos óseos o estos han fracasado. El objetivo de este artículo es proponer el protocolo quirúrgico de colocación de los implantes trascigomáticos y revisar la literatura actual sobre la evolución clínica de estos implantes.The zygomatic implants, originally designed by Branemark in 1989, are implants with a 45 degree inclined head, 4'5 millimetre diameter at their widest part and measuring between 30 and 50 millimetres in length. They are inserted from the palatine side of the alveolar process, following the zygomatic-alveolar edge and anchor in the body of the zygomatic bone. In the case of maxillectomized patients, they are inserted directly in the body of the malar bone. These implants offer an additional alternative to the surgeon when planning an implant supported rehabilitation treatment; specially in those patients with an atrophic maxilla in which osseous grafts cannot be realized or these grafts have failed. The objective of this article is to propose the surgical,protocol of placement of traszygomatic implants and to check the current literature on the clinical evolution of these implants.

  14. Correlation between oxygen vacancies and sites of Mn ions in YMnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Shaobo; Deng, S. Q.; Zhu, Jing, E-mail: jzhu@tsinghua.edu.cn [National Center for Electron Microscopy in Beijing, School of Materials Science and Engineering, The State Key Laboratory of New Ceramics and Fine Processing, Key Laboratory of Advanced Materials (MOE), Tsinghua University, Beijing 100084 (China); Zhao, Y. G. [Department of Physics and State Key Laboratory of Low-Dimensional Quantum Physics, Tsinghua University, Beijing 100084 (China); Sun, X. F. [Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Key Laboratory of Strongly-Coupled Quantum Matter Physics, Chinese Academy of Sciences, Hefei, Anhui 230026 (China); Collaborative Innovation Center of Advanced Microstructures, Nanjing, Jiangsu 210093 (China)

    2015-02-09

    In multiferroic hexagonal manganites (RMnO{sub 3}, R = Y, Sc, Ho-Lu), positions of Mn ions can affect both their in-plane and inter-plane exchange interactions, thus they are of utmost importance for the magneto-elastic coupling of rare-earth compounds. However, the reported in-plane positions of Mn ions by different groups are controversial and there is a lack of convenient method to identify the shift of Mn ions from the center of MnO{sub 5} bipyramids. Here, we demonstrate that the transmission electron microscopy is an efficient technique to characterize the positions of Mn ions and the shift of Mn ions can be directly recognized from the selected area electron diffraction (SAED) patterns. Through systematic studies on the SAED patterns acquired from regions with stoichiometric and non-stoichiometric ratio, we conclude that the intensities of (11{sup ¯}0) and (22{sup ¯}0) diffraction spots are very sensitive to the in-plane positions of Mn ions. We ascribe the off-centered shift of Mn ions to the in-plane oxygen vacancies and this is verified by combined electron microscopy and electron diffraction pattern calculations. Our results indicate that SAED can be used to judge both local positions of Mn ions and local oxygen deficiency in RMnO{sub 3} systems.

  15. Oxygen displacements and magnetoelectric coupling in LuMnO3

    Science.gov (United States)

    Tong, P.; Louca, Despina; Lee, Nara; Cheong, S.-W.

    2012-09-01

    The hexagonal multiferroic LuMnO3 transforms to the P63cm symmetry upon entering the ferroelectric phase. Using neutron diffraction and the pair density function analysis, it is shown that short-range local atomic distortions are present, calling for a lower symmetry, such as the P63, for the following reasons. With cooling, the MnO5 bipyramid tilting becomes more enhanced than previously determined. This splits the in-plane Mn-O-Mn angles especially below TN, leading to inequivalent magnetic coupling constants J between the in-plane Mn ions. Additionally, below TN, several weak incommensurate magnetic phases appear in response to the reminiscent frustration from the triangular Mn lattice. The complex magnetic structure may be the driving mechanism for the lower crystal symmetry.

  16. Ferromagnetic interactions and martensitic transformation in Fe doped Ni-Mn-In shape memory alloys

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, D. N.; Priolkar, K. R., E-mail: krp@unigoa.ac.in [Department of Physics, Goa University, Taleigao Plateau, Goa 403 206 (India); Emura, S. [Institute of Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Nigam, A. K. [Tata Institute of Fundamental Research, Dr. Homi Bhabha Road, Colaba, Mumbai 400 005 (India)

    2014-11-14

    The structure, magnetic, and martensitic properties of Fe doped Ni-Mn-In magnetic shape memory alloys have been studied by differential scanning calorimetry, magnetization, resistivity, X-ray diffraction (XRD), and EXAFS. While Ni{sub 2}MnIn{sub 1−x}Fe{sub x} (0 ≤ x ≤ 0.6) alloys are ferromagnetic and non martensitic, the martensitic transformation temperature in Ni{sub 2}Mn{sub 1.5}In{sub 1−y}Fe{sub y} and Ni{sub 2}Mn{sub 1.6}In{sub 1−y}Fe{sub y} increases for lower Fe concentrations (y ≤ 0.05) before decreasing sharply for higher Fe concentrations. XRD analysis reveals presence of cubic and tetragonal structural phases in Ni{sub 2}MnIn{sub 1−x}Fe{sub x} at room temperature with tetragonal phase content increasing with Fe doping. Even though the local structure around Mn and Ni in these Fe doped alloys is similar to martensitic Mn rich Ni-Mn-In alloys, presence of ferromagnetic interactions and structural disorder induced by Fe affect Mn-Ni-Mn antiferromagnetic interactions resulting in suppression of martensitic transformation in these Fe doped alloys.

  17. Radioactive implants for medical applications; Radioaktive Implantate fuer medizinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, M.

    2008-07-01

    The long-term success of surgery is often diminished by excessive wound healing, which makes another intervention necessary. Locally applied radionuclides with short range radiation can prevent such benign hyperproliferation. As pure electron emitter with a half-life of 14.3 days and a mean energy of 694.9 keV (E{sub max}=1710.48 keV) {sup 32}P is a suitable radionuclide which can be produced from the stable {sup 31}P by the capture of thermal neutrons (1 x 10{sup 14} /s/cm{sup 2}) in a nuclear reactor. After a typical irradiation time (14 days) the ratio of {sup 32}P to {sup 31}P is 1.4 x 10{sup -5} to 1. Implants made of polymer and/or bioabsorbable material functioning as a carrier of the radioactive emitter allow - as opposed to metallic implants - for new applications for this type of radiotherapy. In this thesis a manufacturing method for previously not available organic, radioactive implants has been developed and a corresponding dosimetry system has been established. By means of ion implantation, {sup 32}P ions with up to 180 keV can be shot some 100 nm deep into organic implant materials. For a typical dose (15 Gy over 7 days, 1 mm distance from the implant) an activity of 75 kBq is needed corresponding to 1.3 x 10{sup 11} {sup 32}P ions. The sputter ion gun, which has been optimized for this application, creates an ion beam with high beam current (> 14 {mu}A P{sup -}) and low emittance (< 4 {pi} mm mrad {radical}(MeV)). Because of the good beam quality also small implants (<1 mm{sup 2}) can be manufactured with high efficiency. The unintentionally co-implanted portion of molecules and nuclides of the same mass (e.g. {sup 31}PH, {sup 16}O{sub 2} and {sup 32}S) could be reduced from approximately 500 to 50 by an improvement of the isotope selection at {sup 32}P beam creation. Hence, in comparison with the best hitherto existing implantation methods, the radiation dose of the implant could be reduced by an order of magnitude. With regard to the beta

  18. Prediction of bone density around orthopedic implants delivering bisphosphonate.

    Science.gov (United States)

    Stadelmann, Vincent A; Terrier, Alexandre; Gauthier, O; Bouler, J-M; Pioletti, Dominique P

    2009-06-19

    The fixation of an orthopedic implant depends strongly upon its initial stability. Peri-implant bone may resorb shortly after the surgery. This resorption is directly followed by new bone formation and implants fixation strengthening, the so-called secondary fixation. If the initial stability is not reached, the resorption continues and the implant fixation weakens, which leads to implant loosening. Studies with rats and dogs have shown that a solution to prevent peri-implant resorption is to deliver bisphosphonate from the implant surface. The aims of the study were, first, to develop a model of bone remodeling around an implant delivering bisphosphonate, second, to predict the bisphosphonate dose that would induce the maximal peri-implant bone density, and third to verify in vivo that peri-implant bone density is maximal with the calculated dose. The model consists of a bone remodeling equation and a drug diffusion equation. The change in bone density is driven by a mechanical stimulus and a drug stimulus. The drug stimulus function and the other numerical parameters were identified from experimental data. The model predicted that a dose of 0.3 microg of zoledronate on the implant would induce a maximal bone density. Implants with 0.3 microg of zoledronate were then implanted in rat femurs for 3, 6 and 9 weeks. We measured that peri-implant bone density was 4% greater with the calculated dose compared to the dose empirically described as best. The approach presented in this paper could be used in the design and analysis processes of experiments in local delivery of drug such as bisphosphonate.

  19. Application and Curative Effect of Micro-implant Anchorage in ...

    African Journals Online (AJOL)

    in the treatment group were treated with a micro-implant as the anchorage, while 31 cases of the .... prescribedan oral antibiotic in case of infection ... removed. Local infiltration anesthesia was unnecessary and the wound would heal in a.

  20. Implants in adolescents.

    Science.gov (United States)

    Shah, Rohit A; Mitra, Dipika K; Rodrigues, Silvia V; Pathare, Pragalbha N; Podar, Rajesh S; Vijayakar, Harshad N

    2013-07-01

    Implants have gained tremendous popularity as a treatment modality for replacement of missing teeth in adults. There is extensive research present on the use of implants in adults, but there is a dearth of data available on the same in adolescents. The treatment planning and execution of implant placement in adolescents is still in its infancy. This review article is an attempt to bring together available literature.

  1. Implants in adolescents

    Directory of Open Access Journals (Sweden)

    Rohit A Shah

    2013-01-01

    Full Text Available Implants have gained tremendous popularity as a treatment modality for replacement of missing teeth in adults. There is extensive research present on the use of implants in adults, but there is a dearth of data available on the same in adolescents. The treatment planning and execution of implant placement in adolescents is still in its infancy. This review article is an attempt to bring together available literature.

  2. Implant treatment planning considerations.

    Science.gov (United States)

    Kao, Richard T

    2008-04-01

    As dental implants become a more accepted treatment modality, there is a need for all parties involved with implant dentistry to be familiar with various treatment planning issues. Though the success can be highly rewarding, failure to forecast treatment planning issues can result in an increase of surgical needs, surgical cost, and even case failure. In this issue, the focus is on implant treatment planning considerations.

  3. Magnetic and in vitro heating properties of implants formed in situ from injectable formulations and containing superparamagnetic iron oxide nanoparticles (SPIONs) embedded in silica microparticles for magnetically induced local hyperthermia

    Energy Technology Data Exchange (ETDEWEB)

    Le Renard, Pol-Edern, E-mail: lerenard.pe@gmail.co [School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva (Switzerland); Lortz, Rolf [Department of Physics, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon (Hong Kong); Senatore, Carmine [Department of Condensed Matter Physics and MaNEP/NCCR, University of Geneva, Geneva (Switzerland); Rapin, Jean-Philippe [Laboratory of Crystallography, University of Geneva, Geneva (Switzerland); Buchegger, Franz [Service of Nuclear Medicine, University Hospital of Lausanne, Lausanne, University Hospital of Geneva, Geneva (Switzerland); Petri-Fink, Alke [Department of Chemistry, University of Fribourg, Fribourg (Switzerland); Hofmann, Heinrich [Laboratory for Powder Technology, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne (Switzerland); Doelker, Eric [School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva (Switzerland); Jordan, Olivier, E-mail: olivier.jordan@unige.c [School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva (Switzerland)

    2011-04-15

    The biological and therapeutic responses to hyperthermia, when it is envisaged as an anti-tumor treatment modality, are complex and variable. Heat delivery plays a critical role and is counteracted by more or less efficient body cooling, which is largely mediated by blood flow. In the case of magnetically mediated modality, the delivery of the magnetic particles, most often superparamagnetic iron oxide nanoparticles (SPIONs), is also critically involved. We focus here on the magnetic characterization of two injectable formulations able to gel in situ and entrap silica microparticles embedding SPIONs. These formulations have previously shown suitable syringeability and intratumoral distribution in vivo. The first formulation is based on alginate, and the second on a poly(ethylene-co-vinyl alcohol) (EVAL). Here we investigated the magnetic properties and heating capacities in an alternating magnetic field (141 kHz, 12 mT) for implants with increasing concentrations of magnetic microparticles. We found that the magnetic properties of the magnetic microparticles were preserved using the formulation and in the wet implant at 37 {sup o}C, as in vivo. Using two orthogonal methods, a common SLP (20 W g{sup -1}) was found after weighting by magnetic microparticle fraction, suggesting that both formulations are able to properly carry the magnetic microparticles in situ while preserving their magnetic properties and heating capacities. - Research highlights: > Magnetic formulations that form implants on injection into tissues are proposed for hyperthermia. > Superparamagnetic properties of the SPION-silica composite microparticles are preserved in the wet implants. > Heat-dissipating properties (SLP of 20 W/g of implant) support in vivo use.

  4. Microstructure, mechanical and bio-corrosion properties of Mn-doped Mg–Zn–Ca bulk metallic glass composites

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jingfeng, E-mail: jfwang@cqu.edu.cn [National Engineering Research Center for Magnesium Alloys, College of Materials Science and Engineering, Chongqing University, Chongqing 400044 (China); Huang, Song; Li, Yang; Wei, Yiyun [National Engineering Research Center for Magnesium Alloys, College of Materials Science and Engineering, Chongqing University, Chongqing 400044 (China); Xi, Xingfeng; Cai, Kaiyong [College of Bioengineering, Chongqing University, Chongqing 400044 (China)

    2013-10-15

    The effects of Mn substitution for Mg on the microstructure, mechanical properties, and corrosion behavior of Mg{sub 69−x}Zn{sub 27}Ca{sub 4}Mn{sub x} (x = 0, 0.5 and 1 at.%) alloys were investigated using X-ray diffraction, compressive tests, electrochemical treatments, and immersion tests, respectively. Microstructural observations showed that the Mg{sub 69}Zn{sub 27}Ca{sub 4} alloy was mainly amorphous. The addition of Mn decreases the glass-forming ability, which results in a decreased strength from 545 MPa to 364 MPa. However, this strength is still suitable for implant application. Polarization and immersion tests in the simulated body fluid at 37 °C revealed that the Mn-doped Mg–Zn–Ca alloys have significantly higher corrosion resistance than traditional ZK60 and pure Mg alloys. Cytotoxicity test showed that cell viabilities of osteoblasts cultured with Mn-doped Mg–Zn–Ca alloys extracts were higher than that of pure Mg. Mg{sub 68.5}Zn{sub 27}Ca{sub 4}Mn{sub 0.5} exhibits the highest bio-corrosion resistance, biocompatibility and has desirable mechanical properties, which could suggest to be used as biomedical materials in the future. - Highlights: • Novel Mn-doped Mg–Zn–Ca bulk metallic glass composites were made by copper mold cast. • The strength of the Mn-doped Mg–Zn–Ca is suitable for implant application. • The Mn-doped Mg–Zn–Ca alloys have significantly high bio-corrosion resistance. • The Mn-doped Mg–Zn–Ca alloys show better cell viabilities than that of pure Mg.

  5. HA-Coated Implant

    DEFF Research Database (Denmark)

    Daugaard, Henrik; Søballe, Kjeld; Bechtold, Joan E

    2014-01-01

    The goal of osseointegration of orthopedic and dental implants is the rapid achievement of a mechanically stable and long lasting fixation between living bone and the implant surface. In total joint replacements of cementless designs, coatings of calcium phosphates were introduced as a means...... of improving the fixation of implants. Of these, hydroxyapatite (HA) is the most widely used and most extensively investigated. HA is highly osseoconductive, and the positive effect is well documented in both basic and long-term clinical research [1–6]. This chapter describes experimental and clinical studies...... evaluating bone-implant fixation with HA coatings....

  6. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  7. Treatment Alternatives to Negotiate Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Eli E. Machtei

    2014-01-01

    Full Text Available Peri-implant diseases are becoming a major health issue in dentistry. Despite the magnitude of this problem and the potential grave consequences, commonly acceptable treatment protocols are missing. Hence, the present paper reviews the literature treatment of peri-implantitis in order to explore their benefits and limitations. Treatment of peri-implantitis may include surgical and nonsurgical approaches, either individually or combined. Nonsurgical therapy is aimed at removing local irritants from the implants’ surface with or without surface decontamination and possibly some additional adjunctive therapies agents or devices. Systemic antibiotics may also be incorporated. Surgical therapy is aimed at removing any residual subgingival deposits and additionally reducing the peri-implant pockets depth. This can be done alone or in conjunction with either osseous respective approach or regenerative approach. Finally, if all fails, explantation might be the best alternative in order to arrest the destruction of the osseous structure around the implant, thus preserving whatever is left in this site for future reconstruction. The available literature is still lacking with large heterogeneity in the clinical response thus suggesting possible underlying predisposing conditions that are not all clear to us. Therefore, at present time treatment of peri-implantitis should be considered possible but not necessarily predictable.

  8. Binder-jetting 3D printing and alloy development of new biodegradable Fe-Mn-Ca/Mg alloys.

    Science.gov (United States)

    Hong, Daeho; Chou, Da-Tren; Velikokhatnyi, Oleg I; Roy, Abhijit; Lee, Boeun; Swink, Isaac; Issaev, Ilona; Kuhn, Howard A; Kumta, Prashant N

    2016-11-01

    3D printing of various biomaterials including titanium and stainless steel has been studied for treating patients with cranio-maxillofacial bone defect. The potential long term complications with use of inert biometals have opened the opportunities for use of biodegradable metals in the clinical arena. The authors previously reported that binder-jet 3D printing technique enhanced the degradation rates of biodegradable Fe-Mn alloy by creating engineered micropores rendering the system attractive as biodegradable implantable devices. In the present study, the authors employed CALPHAD modeling to systematically study and modify the Fe-Mn alloy composition to achieve enhanced degradation rates. Accordingly, Ca and Mg addition to Fe-35wt% Mn solid solution predicted increase in degradation rates. In order to validate the CALPHAD results, Fe - (35-y)wt% Mn - ywt% X (X=Ca, Mg, and y=0, 1, 2) were synthesized by using high energy mechanical alloying (HEMA). Sintered pellets of Fe-Mn-Ca and Fe-Mn-Mg were then subjected to potentiodynamic polarization (PDP) and live/dead cell viability tests. Sintered pellets of Fe-Mn, Fe-Mn-Ca, and Fe-Mn-Mg also exhibited MC3T3 murine pre-osteoblast cells viability in the live/dead assay results. Fe-Mn and Fe-Mn-1Ca were thus accordingly selected for 3D printing and the results further confirmed enhanced degradation of Ca addition to 3D printed constructs validating the theoretical and alloy development studies. Live/dead and MTT cell viability results also confirmed good cytocompatibility of the 3D-printed Fe-Mn and Fe-Mn-1Ca constructs. Bone grafting is widely used for the treatment of cranio-maxillofacial bone injuries. 3D printing of biodegradable Fe alloy is anticipated to be advantageous over current bone grafting techniques. 3D printing offers the fabrication of precise and tailored bone grafts to fit the patient specific bone defect needs. Biodegradable Fe alloy is a good candidate for 3D printing synthetic grafts to regenerate bone

  9. Doping and bond length contributions to Mn K-edge shift in La1-SrMnO3 (=0-0.7) and their correlation with electrical transport properties

    Indian Academy of Sciences (India)

    S K Pandey; R Bindu; Ashwini Kumar; S Khalid; A V Pimpale

    2008-02-01

    The room temperature experimental Mn K-edge X-ray absorption spectra of La1-SrMnO3 ( = 0-0.7) are compared with the band structure calculations using spin polarized density functional theory. It is explicitly shown that the observed shift in the energy of Mn K-edge on substitution of divalent Sr on trivalent La sites corresponds to the shift in the center of gravity of the unoccupied Mn 4-band contributing to the Mn K-absorption edge region. This correspondence is then used to separate the doping and size contributions to the edge shift due to variation in the number of electrons in valence band and Mn-O bond lengths, respectively, when Sr is doped into LaMnO3. Such separation is helpful to find the localization behaviour of charge carriers and to understand the observed transport properties of these compounds.

  10. DOPING AND BOND LENGTH CONTRIBUTIONS TO Mn K-EDGE SHIFT IN La1-xSrxMnO3 AND THEIR CORRELATION WITH ELECTRICAL TRANSPORT BEHAVIOUR.

    Energy Technology Data Exchange (ETDEWEB)

    PANDEY,S.K.; KHALID,S.; BINDU, R.; KUMAR, A.; PIMPALE, A.V.

    2006-12-04

    The experimental Mn K-edge x-ray absorption spectra of La{sub 1-x}Sr{sub x}MnO{sub 3}, x = 0 - 0.7 are compared with the band structure calculations using spin polarized density functional theory. It is explicitly shown that there is a correspondence between the inflection point on the absorption edge and the center of gravity of the unoccupied Mn 4p-band. This correspondence has been used to separate the doping and size contributions to edge shift due to variation in number of electrons in valence band and Mn-O bond lengths, respectively when Sr is doped into LaMnO{sub 3}. Such separation is helpful to find the localization behavior of charge carriers and to understand the observed transport properties and type of charge carrier participating in the conduction process in these compounds.

  11. Chemical Evolution of Mn in Three Dwarf Spheroidal Galaxies

    Indian Academy of Sciences (India)

    Men-Quan Liu; Jie Zhang

    2014-09-01

    Based on an improved model, more reasonable nucleosyn-thesis and explosion rate of SNeIa and CCSNe, we studied Mn evolution for three local dwarf spheroidal galaxies (dSphs), considering the detailed SNe yield and explosion rates for different types of progenitors. The results can explain the main observation ofMn abundance for tens stars in those dSphs, and give some constraints to the nucleosynthesis and explosion ratio of different types of supernovae and Star Formation Rates (SFR) in those dSphs.

  12. Mn doped InSb studied at the atomic scale by cross-sectional scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Mauger, S. J. C.; Bocquel, J.; Koenraad, P. M., E-mail: p.m.koenraad@tue.nl [Department of Applied Physics, Eindhoven University of Technology, Den Dolech 2, 5612 AZ Eindhoven (Netherlands); Feeser, C. E.; Parashar, N. D.; Wessels, B. W. [Department of Materials Science and Engineering and Materials Research Center, Northwestern University, Evanston, Illinois 60208 (United States)

    2015-11-30

    We present an atomically resolved study of metal-organic vapor epitaxy grown Mn doped InSb. Both topographic and spectroscopic measurements have been performed by cross-sectional scanning tunneling microscopy (STM). The measurements on the Mn doped InSb samples show a perfect crystal structure without any precipitates and reveal that Mn acts as a shallow acceptor. The Mn concentration of the order of ∼10{sup 20 }cm{sup −3} obtained from the cross-sectional STM data compare well with the intended doping concentration. While the pair correlation function of the Mn atoms showed that their local distribution is uncorrelated beyond the STM resolution for observing individual dopants, disorder in the Mn ion location giving rise to percolation pathways is clearly noted. The amount of clustering that we see is thus as expected for a fully randomly disordered distribution of the Mn atoms and no enhanced clustering or second phase material was observed.

  13. Mechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design.

    Science.gov (United States)

    Prodanov, Dimiter; Delbeke, Jean

    2016-01-01

    Neural prostheses have already a long history and yet the cochlear implant remains the only success story about a longterm sensory function restoration. On the other hand, neural implants for deep brain stimulation are gaining acceptance for variety of disorders including Parkinsons disease and obsessive-compulsive disorder. It is anticipated that the progress in the field has been hampered by a combination of technological and biological factors, such as the limited understanding of the longterm behavior of implants, unreliability of devices, biocompatibility of the implants among others. While the field's understanding of the cell biology of interactions at the biotic-abiotic interface has improved, relatively little attention has been paid on the mechanical factors (stress, strain), and hence on the geometry that can modulate it. This focused review summarizes the recent progress in the understanding of the mechanisms of mechanical interaction between the implants and the brain. The review gives an overview of the factors by which the implants interact acutely and chronically with the tissue: blood-brain barrier (BBB) breach, vascular damage, micromotions, diffusion etc. We propose some design constraints to be considered in future studies. Aspects of the chronic cell-implant interaction will be discussed in view of the chronic local inflammation and the ways of modulating it.

  14. Vickers hardness measurement of ion implanted MgO

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, Y. (TRCRE, JAERI, 1233 Watanuki-machi, Takasaki, Gunma 370-12 (Japan)); Rueck, D.M. (Materialforschung, UNILAC, GSI, D-6100, Darmstadt (Germany)); Vogt, D. (Materialforschung, UNILAC, GSI, D-6100, Darmstadt (Germany)); Leible, K. (Materialforschung, UNILAC, GSI, D-6100, Darmstadt (Germany)); Khubeis, I. (University of Jordan, P.O. Box 13097, Amman (Jordan)); Meyer, O. (INFP, KfK, D-7500, Karlsruhe 1 (Germany))

    1994-06-01

    The Vickers hardness was measured for single crystals of MgO(100) implanted with 130 keV or 1.8 MeV Ar[sup +] ions and with 400 keV Xe[sup 2+] ions by means of the indentation technique with an applied load of 0.4-30 mN. Implantation with 130 keV Ar[sup +] and 400 keV Xe[sup 2+] gave similar results in hardening of MgO surface layers. In addition, the dose dependence of the measured hardness curve showed that a softening mechanism takes place at high doses. High energy implantation (1.8 MeV Ar[sup +]) made a hardened surface layer on MgO. This hardened layer also became softer at high doses. ((orig.))

  15. SrMnII2MnIII(PO43

    Directory of Open Access Journals (Sweden)

    Ghaleb Alhakmi

    2013-09-01

    Full Text Available The title compound, strontium trimanganese tris(orthophosphate, was synthesized under hydrothermal conditions. Its structure is isotypic to that of the lead analogue PbMnII2MnIII(PO43. Two O atoms are in general positions, whereas all others atoms are in special positions. The Sr and one P atom exhibit mm2 symmetry, the MnII atom 2/m symmetry, the MnIII atom and the other P atom .2. symmetry and two O atoms are located on mirror planes. The three-dimensional network of the crystal structure is made up of two types of chains running parallel to [010]. One chain is linear and is composed of alternating MnIIIO6 octahedra and PO4 tetrahedra sharing vertices; the other chain has a zigzag arrangement and is built up from two edge-sharing MnIIO6 octahedra connected to PO4 tetrahedra by edges and vertices. The two types of chains are linked through PO4 tetrahedra, leading to the formation of channels parallel to [100] and [010] in which the SrII ions are located. They are surrounded by eight O atoms in the form of a slightly distorted bicapped trigonal prism.

  16. Management of peri-implantitis

    OpenAIRE

    Jayachandran Prathapachandran; Neethu Suresh

    2012-01-01

    Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless ...

  17. Management of peri-implantitis

    OpenAIRE

    Jayachandran Prathapachandran; Neethu Suresh

    2012-01-01

    Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless ...

  18. Sequential bilateral cochlear implantation in children: parents' perspective and device use.

    Science.gov (United States)

    Sparreboom, Marloes; Leeuw, A Rens; Snik, Ad F M; Mylanus, Emmanuel A M

    2012-03-01

    The purpose of this study was (1) to measure parental expectations before surgery of a sequentially placed second cochlear implant and compare these results with parental observations postoperatively and (2) to measure device use of the second cochlear implant and compare to unilateral implant use. Thirty prelingually deaf children with a unilateral cochlear implant (mean age at first implant 1.8 years) received a second implant at a mean age of 5.3 years. To measure parental expectations and observations, parents completed the Parents' Perspective before surgery of the second implant and after 12 and 24 months. The questionnaire included 1 additional question on sound localization. Device use of both the first and second implants was assessed retrospectively after 6, 12 and 24 months of implant use. Device use of the study group was also compared to a reference group of 30 unilateral implant users matched for age at second implantation. Parental expectations with regard to sound localization were significantly higher than the observed changes within the first year of bilateral implant use. The observed changes in communication, listening to speech without lipreading, and speech and language skills met or surpassed parental expectations. Irrespective of age at second implantation, the second implant was significantly less worn than the first implant. No significant difference was observed between the use of the second implant of the study group and device use of the reference group. Second implant use was significantly correlated with the difference in speech recognition between the 2 implants alone. Preoperative parental expectations were too high with regard to the observed localization skills within the first year of bilateral implant use. The study showed that several of these sequentially implanted children had more difficulties in wearing the second implant than in wearing the first implant during the rehabilitation period. The present results suggest that

  19. Magnetic excitations in the triangular antiferromagnets Mn3Sn and Mn3Ge

    Science.gov (United States)

    Cable, J. W.; Wakabayashi, N.; Radhakrishna, P.

    1993-09-01

    Inelastic neutron scattering was used to study the magnetic excitations of the triangular antiferromagnets Mn3Sn and Mn3Ge. These compounds have itinerant d electrons and large magnetic moments localized at the Mn sites and may be regarded as materials that lie in the intermediate regime between local-moment and itinerant-electron systems. The spin-wave spectra exhibit steep dispersion and strong damping, which is characteristic behavior of itinerant-electron systems. Nevertheless, it is useful to analyze the data in terms of a local-moment model with anisotropy. We find the data are remarkably well described by this model with exchange parameters extending to fifth-nearest neighbors and with both axial- and basal-plane anisotropy. The axial-anisotropy parameters were determined from the uniform out-of-plane spin fluctuation, and the signs show that the spins are confined to the basal plane. The second-order basal-plane anisotropy constants were determined by satisfying both the magnitude of the weak basal-plane ferromagnetic moments and the observed splitting of a doubly degenerate acoustic-spin-wave branch. The sixth-order basal-plane anisotropy was determined by adjusting to the observed energy gap associated with spin fluctuations within the basal plane. The exchange parameters have the correct signs to stabilize the triangular antiferromagnetic structure but yield Néel temperatures that are higher than those observed by a factor of 3 or 4. This overestimation of the Néel temperature is not an uncommon result when a local moment model is applied to an itinerant-electron system.

  20. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne;

    2012-01-01

    We evaluated the association between radiation therapy and severe capsular contracture or reoperation after 717 delayed breast implant reconstruction procedures (288 1- and 429 2-stage procedures) identified in the prospective database of the Danish Registry for Plastic Surgery of the Breast during...... reconstruction approaches other than implants should be seriously considered among women who have received radiation therapy....

  1. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...

  2. IMPLANTABLE COLLAMER LENS IMPLANTATION AND IRIS CERCLAGE FOR THE TREATMENT OF URRETS-ZAVALIA SYNDROME

    Directory of Open Access Journals (Sweden)

    Arnaldo D Santos

    2013-10-01

    Full Text Available A 27-year-old woman with bilateral high myopia had anterior chamber iris-claw phakic IOL implantation in her left eye (LE under local anesthesia, without intraoperative complications. The preoperative slitlamp examination was normal and she had no past medical history. On the second day post-operatory, she developed fixed dilated mydriasis and one month later we documented IOL subluxation. There had been no history of intra-ocular hypertension and no mydriatic drops were used. Diagnosis of Urrets-Zavalia syndrome was established. We removed the IOL and observed for six months after adapting coloured contact lens. During this time she complained about glare, photophobia and developed contact lens intolerance. We decided to implant a posterior chamber Implantable Collamer Lens (ICL and to perform iris cerclage in the LE, with good aesthetic and refractive outcome. Posterior chamber ICL implantation with iris cerclage seems to be a simple and effective approach to this situation.

  3. Percutaneous Edwards SAPIEN valve implantation in the tricuspid position : case report and review of literature

    NARCIS (Netherlands)

    Hoendermis, Elke S.; Douglas, Yvonne L.; van den Heuvel, Ad F. M.

    2012-01-01

    Aims: Experience with transcatheter valve-in-valve implantation in a failing bioprosthetic tricuspid valve is very limited. Fewer than 30 cases have been reported, and in most of them the Melody valve (Medtronic, Inc., Minneapolis, MN, USA) was used. With this case report and review of literature we

  4. MUSIC AND COCHLEAR IMPLANTS

    Institute of Scientific and Technical Information of China (English)

    Mao Yitao; Xu Li

    2013-01-01

    Currently, most people with modern multichannel cochlear implant systems can understand speech in qui-et environment very well. However, studies in recent decades reported a lack of satisfaction in music percep-tion with cochlear implants. This article reviews the literature on music ability of cochlear implant users by presenting a systematic outline of the capabilities and limitations of cochlear implant recipients with regard to their music perception as well as production. The review also evaluates the similarities and differences be-tween electric hearing and acoustic hearing regarding music perception. We summarize the research results in terms of the individual components of music (e.g., rhythm, pitch, and timbre). Finally, we briefly intro-duce the vocal singing of prelingually-deafened children with cochlear implants as evaluated by acoustic measures.

  5. Magnetic analysis of martensitic and austenitic phases in metamagnetic NiMn(In, Sn) alloys

    Energy Technology Data Exchange (ETDEWEB)

    Lázpita, P., E-mail: patricia.lazpita@ehu.es [University of Basque Country (UPV/EHU), Leioa (Spain); Escolar, J. [University of Basque Country (UPV/EHU), Leioa (Spain); Chernenko, V.A. [University of Basque Country (UPV/EHU), Leioa (Spain); BCMaterials, Parque Tecnológico de Bizkaia, Ed. 500, Derio 48160 (Spain); Ikerbasque, Basque Foundation for Science, Bilbao 48013 (Spain); Barandiarán, J.M. [University of Basque Country (UPV/EHU), Leioa (Spain); BCMaterials, Parque Tecnológico de Bizkaia, Ed. 500, Derio 48160 (Spain)

    2015-09-25

    Highlights: • NiMnIn austenite and martensite have similar Ising-type critical exponents. • NiMnIn critical exponents rule out disordered states as spin-glass in martensite. • In NiMnIn alloys, magnetism arises mainly from moments localized at Mn atoms. • NiCoMnSn critical exponents are close to the ones from tricritical mean field model. • NiCoMnSn complex magnetic state results from three different magnetic atoms. - Abstract: Two different metamagnetic shape memory alloys of nominal composition Ni{sub 50}Mn{sub 36}In{sub 14} and Ni{sub 42}Co{sub 8}Mn{sub 39}Sn{sub 11} have been studied by means of modified Arrott plots to give insight into the magnetic states of both the austenitic and martensitic phases. For Ni{sub 50}Mn{sub 36}In{sub 14} alloy, the same critical exponents (β = 0.32 and γ = 2.0) are obtained in austenite and martensite. They suggest that localized moments at Mn atoms are responsible for the magnetism of both phases according to the Ising model. The martensite, however, displays a rather complex behavior because β continuously changes with temperature. In Ni{sub 43}Co{sub 6.5}Mn{sub 39}Sn{sub 11.5}, critical exponents in the austenite are β = 0.27 and γ = 1.0. They are close to the tricritical mean field model, but no reliable fits were obtained in the martensite. The results are discussed in terms of microscopically different magnetic states in two alloys reflecting a complex interplay between the ferromagnetic and antiferromagnetic contributions.

  6. Synthesis and magnetic properties of hexagonal Y(Mn,Cu)O{sub 3} multiferroic materials

    Energy Technology Data Exchange (ETDEWEB)

    Jeuvrey, L., E-mail: laurent.jeuvrey@univ-rennes1.fr [Sciences Chimiques de Rennes, UMR-CNRS 6226, Universite de Rennes 1, 35042 Rennes cedex (France); Pena, O. [Sciences Chimiques de Rennes, UMR-CNRS 6226, Universite de Rennes 1, 35042 Rennes cedex (France); Moure, A.; Moure, C. [Electroceramics Department, Instituto de Ceramica y Vidrio, CSIC, C/Kelsen 5, 28049, Madrid (Spain)

    2012-03-15

    Single-phase hexagonal-type solid solutions based on the multiferroic YMnO{sub 3} material were synthesized by a modified Pechini process. Copper doping at the B-site (YMn{sub 1-x}Cu{sub x}O{sub 3}; x<0.15) and self-doping at the A-site (Y{sub 1+y}MnO{sub 3}; y<0.10) successfully maintained the hexagonal structure. Self-doping was limited to y(Y)=2 at% and confirmed that excess yttrium avoids formation of ferromagnetic manganese oxide impurities but creates vacancies at the Mn site. Chemical substitution at the B-site inhibits the geometrical frustration of the Mn{sup 3+} two-dimensional lattice. The magnetic transition at T{sub N} decreases from 70 K down to 49 K, when x(Cu) goes from 0 to 15 at%. Weak ferromagnetic Mn{sup 3+}-Mn{sup 4+} interactions created by the substitution of Mn{sup 3+} by Cu{sup 2+}, are visible through the coercive field and spontaneous magnetization but do not modify the overall magnetic frustration. Presence of Mn{sup 3+}-Mn{sup 4+} pairs leads to an increase of the electrical conductivity due to thermally-activated small-polaron hopping mechanisms. Results show that local ferromagnetic interactions can coexist within the frustrated state in the hexagonal polar structure. - Highlights: Black-Right-Pointing-Pointer Hexagonal-type solid solutions of Y(Mn,Cu)O{sub 3} synthesized by Pechini process. Black-Right-Pointing-Pointer Chemical substitution at B site inhibits geometrical magnetic frustration. Black-Right-Pointing-Pointer Magnetic transition decreases with Cu-doping. Black-Right-Pointing-Pointer Local ferromagnetic Mn-Mn interactions coexist with the frustrated state.

  7. Electronic structures of MnB soft magnet

    Directory of Open Access Journals (Sweden)

    Jihoon Park

    2016-05-01

    Full Text Available We have calculated the electronic structure of MnB using first-principles calculations based on the density functional theory within the local-spin-density approximation. The temperature dependence of saturation magnetization [Ms(T] was calculated by mean field approximation. The calculated density of states (DOS shows that the energy region near the Fermi energy (EF is mostly attributed to the d bands of Mn. The saturation magnetizations (Ms of MnB were calculated to be 964.5 emu/cm3 (1.21 T at 0 K and 859.3 emu/cm3 (1.08 T at 300 K. The calculated Ms at 300 K is in good agreement with experimental Ms of 851.5 emu/cm3.

  8. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin Pin it More sharing options ... Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ranges from near ...

  9. Influence of trabecular bone quality and implantation direction on press-fit mechanics.

    Science.gov (United States)

    Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E

    2017-02-01

    Achieving primary stability of uncemented press-fit prostheses in patients with poor quality bone can involve axial implantation forces large enough to cause bone fracture. Radial implantation eliminates intraoperative impaction forces and could prevent this damage. Platens of two commercial implant surfaces ("Beaded" and "Flaked") were implanted onto trabecular bone specimens of varying quality in a press-fit simulator. Samples were implanted with varying interference, either axially (shear) or radially (normal). Push-in and pull-out forces were measured to assess stability. Microstructural changes in the bone were determined from μCT analysis. For force-defined implantation analysis, push-in and pull-out forces both increased proportionally with increasing radial force, independent of implantation direction, bone quality or implant surface. For position-defined implantation analysis, pull-out forces were generally found to increase with interference and to be greater for radial than axial implantation direction, and to be lower for poor quality bone. Bone density increased locally at the tested interface due to implantation, in particular for the Beaded surface under axial implantation. If a safe radial stress can be determined for cortical bone in a particular patient, the associated implantation force, and pull-out force which represents primary stability, can be directly derived, regardless of implantation direction, bone quality or implant surface. Radial implantation delivers primary stability that is no worse than that for axial implantation and may eliminate potentially damaging impaction forces. Development of implant designs based on this principal might improve implant fixation. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:224-233, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Effect of 125I permanent implant brachytherapy on clinically localized prostate cancer%永久性125I植入近距离放疗治疗局限性前列腺癌效果观察

    Institute of Scientific and Technical Information of China (English)

    朱再生; 张春霆; 沈艳; 樊静; 刘江; 刘全启; 陈良佑; 罗荣利; 付强

    2016-01-01

    Objective To analyze oncological outcomes of 125I permanent implant brachytherapy (125I-PIB) in clinically localized prostate cancer. Methods Between June 2008 and June 2015, 121 patients with clinically localized prostate cancer were treated with 125I-PIB, and their average age was 72.37 years old. Before treatment, the average prostate-specific antigen (PSA) level was 17.7 ng/ml, prostate volume was (51.4 ±15.0) cm3, the International Prognostic Scoring System (IPSS) score was (21.6 ±2.4) scores. The intermediate-risk and high-risk patients were treated with adjuvant endocrine or supplemental external beam radiotherapy. All patients were followed-up. Biochemical recurrence was defined as the PSA nadir plus 2.0 ng/ml. Results Average follow-up time of the 121 patients was 41.81 months. The prostate volume was (23.1 ± 10.2) cm3, and the IPSS score was (9.7±3.3) scores. Rates of 5-year overall survival, biochemical recurrence-free survival and cancer-specific survival were 86.7 %, 76.7 % and 96.5 %, respectively. 5-year biochemical recurrence-free survival rates were 88.5 %, 67.5 % and 65.2 % in the low-, intermediate-, and high-risk groups, respectively. Biochemical recurrence-free survival did not differ significantly by three risk groups (P=0.103), but the difference between high-risk and low-risk groups was statistically significant (P=0.028). According to multivariate analysis, higher prostate-specific antigen (P=0.021), higher Gleason score (P=0.023) and higher clinical T stage (P=0.037) were the significant covariates associated with biochemical recurrence-free survival. The addition of hormonal therapy or external beam radiation therapy was associated with significantly better outcomes than brachytherapy monotherapy (P=0.036, P=0.027). As for complications, there were 4 cases of surgery (trans-urethral resection of the prostate) and 4 cases of cardiovascular complications. Conclusions The 125I-PIB can bring excellent oncological outcomes and acceptable

  11. Unidirectional expansion of lattice parameters in GaN induced by ion implantation

    Institute of Scientific and Technical Information of China (English)

    Fa Tao; Li Lin; Yao Shu-De; Wu Ming-Fang; Zhou Sheng-Qiang

    2011-01-01

    This paper reports that the 150-keV Mn ions are implanted into GaN thin film grown on Al2O3 by metalorganic chemical vapour deposition. The X-ray diffraction reciprocal spacing mapping is applied to study the lattice parameter variation upon implantation and post-annealing. After implantation, a significant expansion is observed in the perpendicular direction. The lattice strain in perpendicular direction strongly depends on ion fluence and implantation geometry and can be partially relaxed by post-annealing. While in the parallel direction, the lattice parameter approximately keeps the same as the unimplanted GaN, which is independent of ion fluence, implantation geometry and post-annealing temperature.

  12. 唑来膦酸局部治疗对骨质疏松时自体髂骨移植内种植体骨结合的影响%Effect of Local Treatment with Zoledronate Acid on Osseointegration of Dental Implants in Autologous lllac Graft in Os teoporotic Rabbits.

    Institute of Scientific and Technical Information of China (English)

    李剑平; 戚孟春; 石燕萍; 于静; 胡静

    2011-01-01

    Objective: To investigate the effect of local treatment with zoledronate acid on osseointegration of dental implants in autologous lilac graft in osteoporotic rabbits. Methods: Thirty female rabbits were randomly divided into three groups: A, B and C. Animals in group B and C received bilatreal ovariectomy and group A underwent sham operation. 12 weeks after surgery, femoral bones of rabbits were examined for bone mineral density to verify osteoporosis status. Then bone defects were made at the proximal metaphyses of tibiae and autologous iliac bone graft with simultaneous placement of HA coated titanium implants (group A and B) or zoledronate acid immobilized HA -implants (group C) were performed. Animals were killed at 2 and 12 weeks after bone graft surgery and undecalcified sections were prepared and examined histologically and histomorphometrically. Results: Osteoporotic status was verified in ovariectomized rabbits by significantly decreased BMD when compared to sham-operated animals.At 2 weeks after implantation surgery, thickness of cortical bone, bone volume in cancellous area and implant-bone contact rate in group B and C were similar, but all were significantly lower than those in group A. At 12weeks,TCB, IBCR and BVC were highest in group A, followed by group C, and lowest in group B. Compared with 2 weeks, no significant changes for TCB were found at 12 weeks both in group A and in group C, while TCB in group B was slightly decreased. IBCR and BVC at 12 weeks were significantly increased in all groups when compared with those at 2 weeks, except BVC in group B, which was significantly decreased. Conclusion: Experimental osteoporosis can accelerate resorption of bone grafts and decrease cancellous bone volume and implant-bone contact rate, while local treatment with zoledronate acid may resist the negative influence of osteoporosis and increase osseointagration of dental implants.%目的:研究唑来膦酸局部治疗对骨质疏松时自体髂骨移植

  13. Mn tolerance in rice is mediated by MTP8.1, a member of the cation diffusion facilitator family

    Science.gov (United States)

    Ueno, Daisei

    2013-01-01

    Manganese (Mn) is an essential micronutrient for plants, but is toxic when present in excess. The rice plant (Oryza sativa L.) accumulates high concentrations of Mn in the aerial parts; however, the molecular basis for Mn tolerance is poorly understood. In the present study, genes encoding Mn tolerance were screened for by expressing cDNAs of genes from rice shoots in Saccharomyces cerevisiae. A gene encoding a cation diffusion facilitator (CDF) family member, OsMTP8.1, was isolated, and its expression was found to enhance Mn accumulation and tolerance in S. cerevisiae. In plants, OsMTP8.1 and its transcript were mainly detected in shoots. High or low supply of Mn moderately induced an increase or decrease in the accumulation of OsMTP8.1, respectively. OsMTP8.1 was detected in all cells of leaf blades through immunohistochemistry. OsMTP8.1 fused to green fluorescent protein was localized to the tonoplast. Disruption of OsMTP8.1 resulted in decreased chlorophyll levels, growth inhibition in the presence of high concentrations of Mn, and decreased accumulation of Mn in shoots and roots. However, there was no difference in the accumulation of other metals, including Zn, Cu, Fe, Mg, Ca, and K. These results suggest that OsMTP8.1 is an Mn-specific transporter that sequesters Mn into vacuoles in rice and is required for Mn tolerance in shoots. PMID:23963678

  14. High-spin Mn wheels.

    Science.gov (United States)

    Manoli, Maria; Prescimone, Alessandro; Bagai, Rashmi; Mishra, Abhudaya; Murugesu, Muralee; Parsons, Simon; Wernsdorfer, Wolfgang; Christou, George; Brechin, Euan K

    2007-08-20

    The syntheses, structures, and magnetic properties of the complexes [MnIV4MnIII10MnII2O2(OCH3)12(tmp)8(O2CCH3)10].3Et2O (1.3Et2O), [MnIV2MnIII18MnII2O6(OCH3)14(O2CCH3)16(tmp)8(HIm)2].2CH3OH (2.2CH3OH), and [MnIV2MnIII18MnII2O6(OCH3)14(O2CCH3)16(Br-mp)8(HIm)2].2C6H14.5CH3OH (3.2C6H14.5CH3OH) are reported. The unusual wheel-like complexes were prepared by the treatment of [Mn3O(O2CCH3)6(HIm)3](O2CCH3) (HIm = imidazole) with 1,1,1-tris-(hydroxymethyl)propane (H3tmp) (1 and 2) or 2-(bromomethyl)-2-(hydroxymethyl)-1,3-propanediol (Br-mpH3) (3) in the presence of sodium methoxide (NaOCH3, 2, and 3) in CH3OH. Complex 1.3Et2O crystallizes in the triclinic space group P, while complexes 2.2CH3OH and 3.2C6H14.5CH3OH crystallize in the orthorhombic space group Pbca. Direct current magnetic susceptibility data, collected for 1-3 in the respective 1.8-300 K and 0.1-7 T temperature and magnetic-field ranges, afford spin ground-state values of S = 14 +/- 1 for complex 1 and S = 9 +/- 1 for complexes 2 and 3. Alternating current susceptibility measurements performed on all three complexes in the 1.8-10 K temperature range in a 3.5 G oscillating field at frequencies between 50 and 1000 Hz reveal out-of-phase chi"M signals below approximately 3 K. Single-crystal hysteresis loop and relaxation measurements confirm single-molecule magnetism behavior.

  15. Dental Implant Systems

    Science.gov (United States)

    Oshida, Yoshiki; Tuna, Elif B.; Aktören, Oya; Gençay, Koray

    2010-01-01

    Among various dental materials and their successful applications, a dental implant is a good example of the integrated system of science and technology involved in multiple disciplines including surface chemistry and physics, biomechanics, from macro-scale to nano-scale manufacturing technologies and surface engineering. As many other dental materials and devices, there are crucial requirements taken upon on dental implants systems, since surface of dental implants is directly in contact with vital hard/soft tissue and is subjected to chemical as well as mechanical bio-environments. Such requirements should, at least, include biological compatibility, mechanical compatibility, and morphological compatibility to surrounding vital tissues. In this review, based on carefully selected about 500 published articles, these requirements plus MRI compatibility are firstly reviewed, followed by surface texturing methods in details. Normally dental implants are placed to lost tooth/teeth location(s) in adult patients whose skeleton and bony growth have already completed. However, there are some controversial issues for placing dental implants in growing patients. This point has been, in most of dental articles, overlooked. This review, therefore, throws a deliberate sight on this point. Concluding this review, we are proposing a novel implant system that integrates materials science and up-dated surface technology to improve dental implant systems exhibiting bio- and mechano-functionalities. PMID:20480036

  16. Dental Implant Systems

    Directory of Open Access Journals (Sweden)

    Yoshiki Oshida

    2010-04-01

    Full Text Available Among various dental materials and their successful applications, a dental implant is a good example of the integrated system of science and technology involved in multiple disciplines including surface chemistry and physics, biomechanics, from macro-scale to nano-scale manufacturing technologies and surface engineering. As many other dental materials and devices, there are crucial requirements taken upon on dental implants systems, since surface of dental implants is directly in contact with vital hard/soft tissue and is subjected to chemical as well as mechanical bio-environments. Such requirements should, at least, include biological compatibility, mechanical compatibility, and morphological compatibility to surrounding vital tissues. In this review, based on carefully selected about 500 published articles, these requirements plus MRI compatibility are firstly reviewed, followed by surface texturing methods in details. Normally dental implants are placed to lost tooth/teeth location(s in adult patients whose skeleton and bony growth have already completed. However, there are some controversial issues for placing dental implants in growing patients. This point has been, in most of dental articles, overlooked. This review, therefore, throws a deliberate sight on this point. Concluding this review, we are proposing a novel implant system that integrates materials science and up-dated surface technology to improve dental implant systems exhibiting bio- and mechano-functionalities.

  17. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  18. Bioceramics for implant coatings

    Directory of Open Access Journals (Sweden)

    Allison A Campbell

    2003-11-01

    Early research in this field focused on understanding the biomechanical properties of metal implants, but recent work has turned toward improving the biological properties of these devices. This has led to the introduction of calcium phosphate (CaP bioceramics as a bioactive interface between the bulk metal impart and the surrounding tissue. The first CaP coatings were produced via vapor phase processes, but more recently solution-based and biomimetic methods have emerged. While each approach has its own intrinsic materials and biological properties, in general CaP coatings promise to improve implant biocompatibility and ultimately implant longevity.

  19. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2011-01-01

    the period 1999 to 2006; 239 one-stage procedures and 353 two-stage procedures. The postoperative course through November 2009 was evaluated by cumulative incidence adjusting for competing risks for the selected outcomes; hematoma, infection, seroma, implant rupture, severe capsular contracture (modified.......7% for severe capsular contracture, 32.3% for displacement/asymmetry of the implant and 38.6% for reoperation. When comparing one- and two-stage procedures, we observed significantly higher risk estimates for infection, seroma and extrusion of the implant following two-stage procedures, whereas the risk...

  20. Biomedical implantable microelectronics.

    Science.gov (United States)

    Meindl, J D

    1980-10-17

    Innovative applications of microelectronics in new biomedical implantable instruments offer a singular opportunity for advances in medical research and practice because of two salient factors: (i) beyond all other types of biomedical instruments, implants exploit fully the inherent technical advantages--complex functional capability, high reliability, lower power drain, small size and weight-of microelectronics, and (ii) implants bring microelectronics into intimate association with biological systems. The combination of these two factors enables otherwise impossible new experiments to be conducted and new paostheses developed that will improve the quality of human life.

  1. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  2. Silicone breast implants and immune disease.

    Science.gov (United States)

    Shons, A R; Schubert, W

    1992-05-01

    Silicone was originally regarded as inert in the human body. Silicone medical devices have been associated with various complications that may involve an immune reaction to silicone or a silicone organic complex. There have been more than 80 cases reported in the medical literature of a varied systemic autoimmune illness in patients who have had various foreign materials placed in the breast. Controversy exists as to which complications have a cause and effect relationship, and which represent coincidental findings. It is difficult to distinguish between nonspecific local reactions and reactions that have an immunological basis. Approximately 1,000,000 to 2,000,000 women in the United States have had silicone breast implants inserted for reconstruction or augmentation mammaplasty; 28 of those patients have been reported to have developed a systemic autoimmune disease. Data on the 28 reported cases do not in any way prove a causal relationship between breast implants and immune disease. Given the natural incidence of autoimmune diseases, we would expect a coincidental occurrence in the United States of more than 1,000 cases of autoimmune disease in women who had undergone breast implant surgery. Additional information must be obtained to resolve the question. The true incidence of autoimmune disease in patients with implants needs to be determined. A prospective registry of implant patients should be established and comprehensive retrospective information obtained on the implant patient population. Further experimental work is necessary on the bioreactivity of silicone. Patients with implants and autoimmune disease, once identified, must be carefully evaluated by physicians who are experienced in the treatment of autoimmune disease.

  3. The Mn site in Mn-doped Ga-As nanowires: an EXAFS study

    OpenAIRE

    d'Acapito, F.; Rovezzi, M.; Boscherini, F; Jabeen, F; Bais, G.; Piccin, M.; Rubini, S.; Martelli, F.

    2012-01-01

    We present an EXAFS study of the Mn atomic environment in Mn-doped GaAs nanowires. Mn doping has been obtained either via the diffusion of the Mn used as seed for the nanowire growth or by providing Mn during the growth of Au-induced wires. As a general finding, we observe that Mn forms chemical bonds with As but is not incorporated in a substitutional site. In Mn-induced GaAs wires, Mn is mostly found bonded to As in a rather disordered environment and with a stretched bond length, reminisce...

  4. Magnetic exchange interactions in Mn doped ZnSnAs{sub 2} chalcopyrite

    Energy Technology Data Exchange (ETDEWEB)

    Bouhani-Benziane, H.; Sahnoun, O. [Laboratoire de Physique Quantique de la Matière et Modélisation Mathématique (LPQ3M), University of Mascara (Algeria); Sahnoun, M., E-mail: sahnoun_cum@yahoo.fr [Laboratoire de Physique Quantique de la Matière et Modélisation Mathématique (LPQ3M), University of Mascara (Algeria); Department of Chemistry, University of Fribourg (Switzerland); Driz, M. [Laboratoire de Sciences des Matériaux (LSM), University of Sidi Bel Abbes (Algeria); Daul, C. [Department of Chemistry, University of Fribourg (Switzerland)

    2015-12-15

    Accurate ab initio full-potential augmented plane wave (FP-LAPW) electronic calculations within generalized gradient approximation have been performed for Mn doped ZnSnAs{sub 2} chalcopyrites, focusing on their electronic and magnetic properties as a function of the geometry related to low Mn-impurity concentration and the spin magnetic alignment (i.e., ferromagnetic vs antiferromagnetic). As expected, Mn is found to be a source of holes and localized magnetic moments of about 4 µ{sub B} per Mn atom are calculated which are sufficiently large. The defect calculations are firstly performed by replacing a single cation (namely Zn and Sn) with a single Mn atom in the pure chalcopyrite ZnSnAs{sub 2} supercell, and their corresponding formation energies show that the substitution of a Sn atom (rather than Zn) by Mn is strongly favored. Thereafter, a comparison of total energy differences between ferromagnetic (FM) and antiferromagnetic (AFM) are given. Surprisingly, the exchange interaction between a Mn pairs is found to oscillate with the distance between them. Consequently, the AFM alignment is energetically favored in Mn-doped ZnSnAs{sub 2} compounds, except for low impurity concentration associated with lower distances between neighboring Mn impurities, in this case the stabilization of FM increases. Moreover, the ferromagnetic alignment in the Mn-doped ZnSnAs{sub 2} systems behaves half-metallic; the valence band for majority spin orientation is partially filled while there is a gap in the density of states for the minority spin orientation. This semiconducting gap of ~1 eV opened up in the minority channel and is due to the large bonding–antibonding splitting from the p–d hybridization. Our findings suggest that the Mn-doped ZnSnAs{sub 2} chalcopyrites could be a different class of ferromagnetic semiconductors. - Highlights: • ab initio calculations were performed on Mn doped ZnSnAs{sub 2} chalcopyrite. • Substitution of a Sn atom (rather than Zn) by Mn

  5. Expression of Mn-Superoxide Dismutase Gene in Nontumorigenic and Tumorigenic Human Mammary Epithelial Cells

    Directory of Open Access Journals (Sweden)

    Sutapa Mukhopadhyay

    2004-01-01

    Full Text Available Manganese superoxide dismutase (Mn-SOD, localized at the mitochondrial matrix, has the ability to protect cells against oxidative damage. It has been reported that low levels of Mn-SOD gene expression cause the development of certain kind of tumors. On the other hand, overexpression of Mn-SOD gene may play an important role in the development of cancer. In our study, we find that Mn-SOD activity was higher in nonaggressive (MCF-7 and aggressive (BT-549 and 11-9-14 breast cancer cell lines compared to that of nontumorigenic (MCF-12A and MCF-12F mammary epithelial cell lines. We also observed an increased expression of Mn-SOD gene in cancerous cell lines. The elevated level of SOD activity in nonaggressive and aggressive breast epithelial cell lines was associated with some changes in nucleotide sequence.

  6. The electronic structure of homogeneous ferromagnetic (Ga, Mn)N epitaxial films

    Energy Technology Data Exchange (ETDEWEB)

    Piskorska-Hommel, E., E-mail: e.piskorska@int.pan.wroc.pl [Institute of Low Temperature and Structure Research, Polish Academy of Sciences, Institute W. Trzebiatowski, Wroclaw (Poland); Institute of Solid State Physics, University of Bremen, Bremen (Germany); Winiarski, M. J. [Institute of Low Temperature and Structure Research, Polish Academy of Sciences, Institute W. Trzebiatowski, Wroclaw (Poland); Kunert, G.; Falta, J. [Institute of Solid State Physics, University of Bremen, Bremen (Germany); Demchenko, I. N. [Institute of Physic, Polish Academy of Sciences, Warsaw (Poland); Roshchupkina, O. D.; Grenzer, J. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Ion Beam Physics and Materials Research, Bautzner Landstraße 400, 01328 Dresden (Germany); Hommel, D. [Institute of Solid State Physics, University of Bremen, Bremen (Germany); Wrocław Research Center EIT+ Sp. z o.o., Wroclaw (Poland); Experimental Physics, University of Wroclaw, Wroclaw (Poland); Holý, V. [Department of Condensed Matter Physics, Faculty of Mathematics and Physics, Charles University in Prague, Praha (Czech Republic)

    2015-02-14

    X-ray Absorption Fine Structure (XAFS) techniques, namely, X-ray Near Edge Structure (XANES), Extended XAFS (EXAFS), and Anomalous X-ray Diffraction (AXRD) were used to investigate the local atomic and electronic structure of (Ga, Mn)N magnetic layers with Mn concentrations of up to 10% grown by Molecular Beam Epitaxy. The XANES and AXRD analysis prove the Mn incorporation on substitutional GaN lattice sites. EXAFS results indicate the good quality of the structure under examination, although 0.5 nitride atom vacancies were found. The Wien2k code was applied to interpret the XANES spectra quantitatively, i.e., to determine the electronic structure of the Mn atoms. It was shown that accounting for the core-hole effect is necessary to reconstruct effectively the XANES spectra. Conducted charge density analysis based on DFT calculations identified the valency of Mn atom to be of 2.4+.

  7. Investigation of the critical relaxation in MnF$_{2}$ by muon spin rotation

    CERN Document Server

    De Renzi, R; Cox, S F J; Guidi, G; Tedeschi, R A

    1982-01-01

    The magnetic relaxation in MnF/sub 2/ has been studied by means of Muon Spin Rotation. An increase was found close to T/sub N/ in the damping of the precession signal from positive muons implanted in a single-crystal sample. This is attributed to the critical slowing down of the antiferromagnetic spin fluctuations. An orientation-dependent shift in the signal frequency was also detected. The location of the muon in the lattice is tentatively determined.

  8. Improved log(gf ) Values of Selected Lines in Mn I and Mn II for Abundance Determinations in FGK Dwarfs and Giants

    Science.gov (United States)

    Den Hartog, E. A.; Lawler, J. E.; Sobeck, J. S.; Sneden, C.; Cowan, J. J.

    2011-06-01

    The goal of the present work is to produce transition probabilities with very low uncertainties for a selected set of multiplets of Mn I and Mn II. Multiplets are chosen based upon their suitability for stellar abundance analysis. We report on new radiative lifetime measurements for 22 levels of Mn I from the e 8 D, z 6 P, z 6 D, z 4 F, e 8 S, and e 6 S terms and six levels of Mn II from the z 5 P and z 7 P terms using time-resolved laser-induced fluorescence on a slow atom/ion beam. New branching fractions for transitions from these levels, measured using a Fourier-transform spectrometer, are reported. When combined, these measurements yield transition probabilities for 47 transitions of Mn I and 15 transitions of Mn II. Comparisons are made to data from the literature and to Russell-Saunders (LS) theory. In keeping with the goal of producing a set of transition probabilities with the highest possible accuracy and precision, we recommend a weighted mean result incorporating our measurements on Mn I and II as well as independent measurements or calculations that we view as reliable and of a quality similar to ours. In a forthcoming paper, these Mn I/II transition probability data will be utilized to derive the Mn abundance in stars with spectra from both space-based and ground-based facilities over a 4000 Å wavelength range. With the employment of a local thermodynamic equilibrium line transfer code, the Mn I/II ionization balance will be determined for stars of different evolutionary states.

  9. DEALING WITH DENTAL IMPLANT FAILURES

    Science.gov (United States)

    Levin, Liran

    2008-01-01

    An implant-supported restoration offers a predictable treatment for tooth replacement. Reported success rates for dental implants are high. Nevertheless, failures that mandate immediate implant removal do occur. The consequences of implant removal jeopardize the clinician's efforts to accomplish satisfactory function and esthetics. For the patient, this usually involves further cost and additional procedures. The aim of this paper is to describe different methods and treatment modalities to deal with dental implant failure. The main topics for discussion include identifying the failing implant, implants replacing failed implants at the exact site, and the use of other restorative options. When an implant fails, a tailor made treatment plan should be provided to each patient according to all relevant variables. Patients should be informed regarding all possible treatment modalities following implant failure and give their consent to the most appropriate treatment option for them. PMID:19089213

  10. Dealing with dental implant failures

    Directory of Open Access Journals (Sweden)

    Liran Levin

    2008-06-01

    Full Text Available An implant-supported restoration offers a predictable treatment for tooth replacement. Reported success rates for dental implants are high. Nevertheless, failures that mandate immediate implant removal do occur. The consequences of implant removal jeopardize the clinician's efforts to accomplish satisfactory function and esthetics. For the patient, this usually involves further cost and additional procedures. The aim of this paper is to describe different methods and treatment modalities to deal with dental implant failure. The main topics for discussion include identifying the failing implant, implants replacing failed implants at the exact site, and the use of other restorative options.When an implant fails, a tailor made treatment plan should be provided to each patient according to all relevant variables. Patients should be informed regarding all possible treatment modalities following implant failure and give their consent to the most appropriate treatment option for them.

  11. Superelastic Orthopedic Implant Coatings

    Science.gov (United States)

    Fournier, Eric; Devaney, Robert; Palmer, Matthew; Kramer, Joshua; El Khaja, Ragheb; Fonte, Matthew

    2014-07-01

    The demand for hip and knee replacement surgery is substantial and growing. Unfortunately, most joint replacement surgeries will fail within 10-25 years, thereby requiring an arduous, painful, and expensive revision surgery. To address this issue, a novel orthopedic implant coating material ("eXalt") has been developed. eXalt is comprised of super elastic nitinol wire that is knit into a three-dimensional spacer fabric structure. eXalt expands in vivo to conform to the implantation site and is porous to allow for bone ingrowth. The safety and efficacy of eXalt were evaluated through structural analysis, mechanical testing, and a rabbit implantation model. The results demonstrate that eXalt meets or exceeds the performance of current coating technologies with reduced micromotion, improved osseointegration, and stronger implant fixation in vivo.

  12. MEMS biomedical implants

    Institute of Scientific and Technical Information of China (English)

    Tai Yuchong

    2012-01-01

    The field of micro-electro-mechanical systems (MEMS) has advanced tremendously for the last 20 years. Most commercially noticeably, the field has successfully advanced from pressure sensors to micro physical sensors, such as accelerometers and gyros, for handheld electronics application. In parallel, MEMS has also advanced into micro total analysis system(TAS) and/or lab-on-a-chip applications. This article would discuss a relatively new but promising future direction towards MEMS biomedical implants. Specifically, Parylene C has been explored to be used as a good MEMS implant material and will be discussed in detail. Demonstrated implant devices, such as retinal and spinal cord implants, are presented in this article.

  13. Risks of Breast Implants

    Science.gov (United States)

    ... an infection or injury. Demonstrated by redness, swelling, warmth, pain and or/loss of function. Lymphedema or ... Overfilling or underfilling of saline-filled breast implants Physical stresses such as trauma or intense physical pressure ...

  14. Port type is a possible risk factor for implantable venous access port-related bloodstream infections and no sign of local infection predicts the growth of gram-negative bacilli.

    Science.gov (United States)

    Hsu, Jui-Feng; Chang, Hsu-Liang; Tsai, Ming-Ju; Tsai, Ying-Ming; Lee, Yen-Lung; Chen, Pei-Huan; Fan, Wen-Chieh; Su, Yu-Chung; Yang, Chih-Jen

    2015-09-30

    Implantable venous access port (IVAP)-related blood stream infections (BSIs) are one of the most common complications of implantable venous ports. The risk factors and pathogens for IVAP-related BSIs are still controversial. We retrospectively reviewed all patients who received IVAPs at a Hospital in Taiwan from January 1, 2011 to June 31, 2014. Two types of venous port, BardPort® 6.6 fr (Bard port) and Autosuture Chemosite® 7.5 fr (TYCO port) were used. All patients with clinically proven venous port-related BSIs were enrolled. A total of 552 patients were enrolled. There were 34 episodes of IVAP-related BSIs during the study period for a total incidence of 0.177 events/1000 catheter days. Port type (TYCO vs. Bard, HR = 7.105 (95% confidence interval (CI), 1.688-29.904), p = 0.0075), age > 65 years (HR = 2.320 (95 % CI, 1.179-4.564), p = 0.0148), and lung cancer (HR = 5.807 (95% CI, 2.946-11.447), p gram-negative bacilli (p = 0.031). TYCO venous ports, age > 65 years, and lung cancer were all significant risk factors for IVAP-related BSIs, and no sign of infection was significantly associated with the growth of gram-negative bacilli.

  15. Implantation Serine Proteinases heterodimerize and are critical in hatching and implantation

    Directory of Open Access Journals (Sweden)

    Meng Guoliang

    2006-12-01

    Full Text Available Abstract Background We have recently reported the expression of murine Implantation Serine Proteinase genes in pre-implantation embryos (ISP1 and uterus (ISP1 and ISP2. These proteinases belong to the S1 proteinase family and are similar to mast cell tryptases, which function as multimers. Results Here, we report the purification and initial characterization of ISP1 and 2 with respect to their physico-chemical properties and physiological function. In addition to being co-expressed in uterus, we show that ISP1 and ISP2 are also co-expressed in the pre-implantation embryo. Together, they form a heterodimer with an approximate molecular weight of 63 kD. This complex is the active form of the enzyme, which we have further characterized as being trypsin-like, based on substrate and inhibitor specificities. In addition to having a role in embryo hatching and outgrowth, we demonstrate that ISP enzyme is localized to the site of embryo invasion during implantation and that its activity is important for successful implantation in vivo. Conclusion On the basis of similarities in structural, chemical, and functional properties, we suggest that this ISP enzyme complex represents the classical hatching enzyme, strypsin. Our results demonstrate a critical role for ISP in embryo hatching and implantation.

  16. Cochlear Implant in Adults

    Directory of Open Access Journals (Sweden)

    Jaleh Samadi

    2003-09-01

    Full Text Available Cochlear implant is the result of a great combination and collaboration of engineering and medicine. It is mainly because it has the most conflict with the human nervous system among all prosthesis. Cochlear implant helps a child with profound hearing loss to understand and articulate speech and let an adult person with hearing loss communicate with people by phone. Although these wonderful results could not be seen in all patients, will let us know about the great scientific findings.

  17. Ferromagnetism appears in nitrogen implanted nanocrystalline diamond films

    Energy Technology Data Exchange (ETDEWEB)

    Remes, Zdenek [Institute of Physics ASCR v.v.i., Cukrovarnicka 10, 162 00 Prague 6 (Czech Republic); Sun, Shih-Jye, E-mail: sjs@nuk.edu.tw [Department of Applied Physics, National University of Kaohsiung, Kaohsiung 811, Taiwan (China); Varga, Marian [Department of Applied Physics, National University of Kaohsiung, Kaohsiung 811, Taiwan (China); Chou, Hsiung [Department of Physics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Hsu, Hua-Shu [Department of Applied Physics, National Pingtung University of Education, Pingtung 900, Taiwan (China); Kromka, Alexander [Department of Applied Physics, National University of Kaohsiung, Kaohsiung 811, Taiwan (China); Horak, Pavel [Nuclear Physics Institute, 250 68 Rez (Czech Republic)

    2015-11-15

    The nanocrystalline diamond films turn to be ferromagnetic after implanting various nitrogen doses on them. Through this research, we confirm that the room-temperature ferromagnetism of the implanted samples is derived from the measurements of magnetic circular dichroism (MCD) and superconducting quantum interference device (SQUID). Samples with larger crystalline grains as well as higher implanted doses present more robust ferromagnetic signals at room temperature. Raman spectra indicate that the small grain-sized samples are much more disordered than the large grain-sized ones. We propose that a slightly large saturated ferromagnetism could be observed at low temperature, because the increased localization effects have a significant impact on more disordered structure. - Highlights: • Nitrogen implanted nanocrystalline diamond films exhibit ferromagnetism at room temperature. • Nitrogen implants made a Raman deviation from the typical nanocrystalline diamond films. • The ferromagnetism induced from the structure distortion is dominant at low temperature.

  18. BMP-Functionalised Coatings to Promote Osteogenesis for Orthopaedic Implants

    Directory of Open Access Journals (Sweden)

    Jianfeng Wang

    2014-06-01

    Full Text Available The loss of bone integrity can significantly compromise the aesthetics and mobility of patients and can be treated using orthopaedic implants. Over the past decades; various orthopaedic implants; such as allografts; xenografts and synthetic materials; have been developed and widely used in clinical practice. However; most of these materials lack intrinsic osteoinductivity and thus cannot induce bone formation. Consequently; osteoinductive functionalisation of orthopaedic implants is needed to promote local osteogenesis and implant osteointegration. For this purpose; bone morphogenetic protein (BMP-functionalised coatings have proven to be a simple and effective strategy. In this review; we summarise the current knowledge and recent advances regarding BMP-functionalised coatings for orthopaedic implants.

  19. Features of direct implantation in chronic foci of odontogenic infection

    Directory of Open Access Journals (Sweden)

    Gudaryan А.А.

    2016-12-01

    Full Text Available The article presents the results of the developed therapeutic and prophylactic complex and efficacy of immediate implantation in 66 patients with chronic foci of odontogenic infection in the periapical region. Objective: to increase preventive measures of inflammatory and infectious complications and optimization of osteo-integrative processes in immediate implantation after tooth extraction, with periapical foci of chronic infection. It was found that the use of the developed medical complex of following up direct implantation includes the use of local photodynamic therapy, platelet, rich in fibrin as a injection and membranes; this allowed to create a favorable background for the prevention of inflammatory and infectious complications in the peri-implant area and created a favorable background for the osseo-integration of implants in 97.1% of the investigated.

  20. Manganese (Mn) Oxidation Increases Intracellular Mn in Pseudomonas putida GB-1

    Science.gov (United States)

    Banh, Andy; Chavez, Valarie; Doi, Julia; Nguyen, Allison; Hernandez, Sophia; Ha, Vu; Jimenez, Peter; Espinoza, Fernanda; Johnson, Hope A.

    2013-01-01

    Bacterial manganese (Mn) oxidation plays an important role in the global biogeochemical cycling of Mn and other compounds, and the diversity and prevalence of Mn oxidizers have been well established. Despite many hypotheses of why these bacteria may oxidize Mn, the physiological reasons remain elusive. Intracellular Mn levels were determined for Pseudomonas putida GB-1 grown in the presence or absence of Mn by inductively coupled plasma mass spectrometry (ICP-MS). Mn oxidizing wild type P. putida GB-1 had higher intracellular Mn than non Mn oxidizing mutants grown under the same conditions. P. putida GB-1 had a 5 fold increase in intracellular Mn compared to the non Mn oxidizing mutant P. putida GB-1-007 and a 59 fold increase in intracellular Mn compared to P. putida GB-1 ∆2665 ∆2447. The intracellular Mn is primarily associated with the less than 3 kDa fraction, suggesting it is not bound to protein. Protein oxidation levels in Mn oxidizing and non oxidizing cultures were relatively similar, yet Mn oxidation did increase survival of P. putida GB-1 when oxidatively stressed. This study is the first to link Mn oxidation to Mn homeostasis and oxidative stress protection. PMID:24147089

  1. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  2. Biomaterials in cochlear implants

    Directory of Open Access Journals (Sweden)

    Lenarz, Thomas

    2009-01-01

    Full Text Available The cochlear implant (CI represents, for almost 25 years now, the gold standard in the treatment of children born deaf and for postlingually deafened adults. These devices thus constitute the greatest success story in the field of ‘neurobionic’ prostheses. Their (now routine fitting in adults, and especially in young children and even babies, places exacting demands on these implants, particularly with regard to the biocompatibility of a CI’s surface components. Furthermore, certain parts of the implant face considerable mechanical challenges, such as the need for the electrode array to be flexible and resistant to breakage, and for the implant casing to be able to withstand external forces. As these implants are in the immediate vicinity of the middle-ear mucosa and of the junction to the perilymph of the cochlea, the risk exists – at least in principle – that bacteria may spread along the electrode array into the cochlea. The wide-ranging requirements made of the CI in terms of biocompatibility and the electrode mechanism mean that there is still further scope – despite the fact that CIs are already technically highly sophisticated – for ongoing improvements to the properties of these implants and their constituent materials, thus enhancing the effectiveness of these devices. This paper will therefore discuss fundamental material aspects of CIs as well as the potential for their future development.

  3. Anodized dental implant surface.

    Science.gov (United States)

    Mishra, Sunil Kumar; Kumar, Muktadar Anand; Chowdhary, Ramesh

    2017-01-01

    Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  4. Biocompatible implant surface treatments.

    Science.gov (United States)

    Pattanaik, Bikash; Pawar, Sudhir; Pattanaik, Seema

    2012-01-01

    Surface plays a crucial role in biological interactions. Surface treatments have been applied to metallic biomaterials in order to improve their wear properties, corrosion resistance, and biocompatibility. A systematic review was performed on studies investigating the effects of implant surface treatments on biocompatibility. We searched the literature using PubMed, electronic databases from 1990 to 2009. Key words such as implant surface topography, surface roughness, surface treatment, surface characteristics, and surface coatings were used. The search was restricted to English language articles published from 1990 to December 2009. Additionally, a manual search in the major dental implant journals was performed. When considering studies, clinical studies were preferred followed by histological human studies, animal studies, and in vitro studies. A total of 115 articles were selected after elimination: clinical studies, 24; human histomorphometric studies, 11; animal histomorphometric studies, 46; in vitro studies, 34. The following observations were made in this review: · The focus has shifted from surface roughness to surface chemistry and a combination of chemical manipulations on the porous structure. More investigations are done regarding surface coatings. · Bone response to almost all the surface treatments was favorable. · Future trend is focused on the development of osteogenic implant surfaces. Limitation of this study is that we tried to give a broader overview related to implant surface treatments. It does not give any conclusion regarding the best biocompatible implant surface treatment investigated till date. Unfortunately, the eventually selected studies were too heterogeneous for inference of data.

  5. Mn and Fe Impurities in Si$_{1-x}$ Ge$_{x}$ alloys

    CERN Multimedia

    2002-01-01

    Following our investigations of Mn and Fe impurities in elemental semiconductors and in silicon in particular by means of on-line $^{57}$Fe Mössbauer spectroscopy, utilizing radioactive $^{57}$Mn$^{+}$ ion beams at ISOLDE, we propose to extend these studies to bulk and epitaxially-grown Si$_{1-x}$Ge$_{x}$ alloys. In these materials, although already successfully employed in electronic devices, little is known about point defects and important harmful 3d impurities. The experiments aim to determine a variety of fundamental properties: The lattice location of ion-implanted Mn/Fe, the electronic and vibrational properties of dilute Fe impurities in different lattice sites, the charge-state and composition dependence of the diffusivity of interstitial Fe on an atomic scale, the reactions and formation of complexes with lattice defects created by the $^{57}$Mn implantation or by the recoil effect in the nuclear decay to the Mössbauer state of $^{57m}$Fe. Feasibility studies in 2003 indicate that these aims can b...

  6. Basis of bone metabolism around dental implants during osseointegration and peri-implant bone loss.

    Science.gov (United States)

    Insua, Angel; Monje, Alberto; Wang, Hom-Lay; Miron, Richard J

    2017-07-01

    Despite the growing number of publications in the field of implant dentistry, there are limited studies to date investigating the biology and metabolism of bone healing around dental implants and their implications in peri-implant marginal bone loss. The aim of this review article is to provide a thorough understanding of the biological events taking place during osseointegration and the subsequent early and late phases of bone remodeling around dental implants. An update on the coupling mechanism occurring during bone resorption-bone remodeling is provided, focused on the relevance of the osteocytes, bone lining cells and immune cells during bone maintenance. An electronic and manual literature search was conducted by three independent reviewers in several databases, including MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and Cochrane Oral Health Group Trials Register databases for articles up to September 2016 with no language restriction. Local bone metabolism is subject to signals from systemic calcium-phosphate homeostasis and bone remodeling. Three areas of interest were reviewed due to recent reported compromises in bone healing including the putative effects of (1) cholesterol, (2) hyperlipidemia, and (3) low vitamin D intake. Moreover, the prominent influence of osteocytes and immune cells is discussed as being key regulators during dental implant osseointegration and maintenance. These cells are of crucial importance in the presence of biofilm accumulation and their associated byproducts that leads to hard and soft tissue breakdown; the so called peri-implantitis. Factors that could negatively impact osteoclastogenesis or osteal macrophage activation should be monitored in future research including implant placement/torque protocols, bone characteristics, as well as meticulous maintenance programs to favor osseointegration and future long-term stability and success of dental implants. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res

  7. Optical Properties and Photocatalytic Activity of Marokite-Type CaMn2O4

    Institute of Scientific and Technical Information of China (English)

    WU Xue-Wei; ZHANG Hai-Xin; LIU Xiao-Jun; ZHANG Xing-Gan

    2011-01-01

    The optical properties and electronic structure of marokite-type CaMn2O4 are investigated by using UV-vis spectroscopy and the local-spin-density approximation plus the Hubbard-U (LSDA +U ) method.Four absorption bands are observed at 638nm (1.94eV),512nm (2.42eV),377nm (3.29eV) and 248nm (5.00eV),which are ascribed to the charge transfer transitions O2p↑→Mn3d eg↑,O2p↓→Mn3d eg↑,Mn3d eg↑→Mn3d t2g↓ and O2p↑→Mn3d t2g↓,respectively.We further use CaMn2O4 as a photocatalyst to decompose an azo-dye acid orange 7 (AO7) under irradiation of visible light and find that the decomposition ratio of AO7 reaches 15.9% under the irradiation of visible light for two hours.Photocatalysis with oxide semiconductors has attracted increasing attention due to its high efficiency and potential for wide applications in environmental pollution decomposition.[1-3]%The optical properties and electronic structure of marokite-type CaMn2 O4 are investigated by using UV-vis spectroscopy and the local-spin-density approximation plus the Hubbard-U (LSDA+U) method. Four absorption bands are observed at 638nm (1.94eV), 512nm (2.42eV), 377nm (3.29eV) and 248nm (5.00eV), which are ascribed to the charge transfer transitions O2p↑→Mn3d e9↑, 02p↓→Mn3d e9↑, Mn3d e9↑→Mn3d t2g↓ and O2p↑→Mn'id t2g↓, respectively. We further use CaMn2O4 as a photocatalyst to decompose an azo-dye acid orange 7 (AO7) under irradiation of visible light and find that the decomposition ratio of A07 reaches 15.9% under the irradiation of visible light for two hours.

  8. Site Determination and Magnetism of Mn Doping in Protein Encapsulated Iron Oxide Nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Pool, V.; Klem, M.; Jolley, J.; Arenholz, E.A.; Douglas, T.; Young, M.; Idzerda, Y.U.

    2010-01-11

    Soft-X-ray absorption spectroscopy, soft-X-ray magnetic circular dichroism, and alternating current magnetic susceptibility were performed on 6.7 nm iron oxide nanoparticles doped with (5-33%) Mn grown inside the horse-spleen ferritin protein cages and compared to similarly protein encapsulated pure Fe-oxide and Mn-oxide nanoparticles to determine the site of the Mn dopant and to quantify the magnetic behavior with varying Mn concentration. The Mn dopant is shown to substitute preferentially as Mn{sup +2} and prefers the octahedral site in the defected spinel structure. The Mn multiplet structure for the nanoparticles is simpler than for the bulk standards, suggesting that the nanoparticle lattices are relaxed from the distortions present in the bulk. Addition of Mn is found to alter the host Fe-oxide lattice from a defected ferrimagnetic spinel structure similar to {gamma}-Fe{sub 2}O{sub 3} to an non-ferromagnetic spinel structure with a local Fe environment similar to Fe{sub 3}O{sub 4}.

  9. Collinear antiferromagnetism in trigonal SrMn2As2 revealed by single crystal neutron diffraction

    Science.gov (United States)

    Kreyssig, A.; Das, P.; Sangeetha, N. S.; Benson, Z. A.; Heitman, T.; Johnston, D. C.; Goldman, A. I.

    FeAs-based compounds and related materials have been an area of intense research in understanding the complex interplay between magnetism and superconductivity. Here we report on the magnetic structure of SrMn2As2 that crystallizes in a trigonal structure (P 3 m1) and undergoes an antiferromagnetic (AFM) transition at TN ~ 120 K. The temperature dependence of the magnetic susceptibility remains nearly constant below TN with H ∥ c while it decreases significantly with H ∥ ab . This shows that the local Mn moments order and lie in the ab plane instead of aligning along the c axis as in BaMn2As2. Single crystal neutron diffraction measurements on SrMn2As2 determined that the Mn moments are collinearly aligned in a G-type AFM order with AFM alignments between a moment and all nearest neighbors in the basal plane and also perpendicular to it. This manifests that G-type AFM order is robust for Mn122 systems despite different symmetries, i.e. tetragonal for BaMn2As2 and trigonal for SrMn2As2.Work at Ames Laboratory was supported by the DOE, BES, Division of Materials Sciences & Engineering, through DE-AC02-07CH11358. This research used resources at University of Missouri Research Reactor.

  10. Electrochemical Disinfection of Dental Implants – a Proof of Concept

    Science.gov (United States)

    Mohn, Dirk; Zehnder, Matthias; Stark, Wendelin J.; Imfeld, Thomas

    2011-01-01

    Background Peri-implantitis has gained significant clinical attention in recent years. This disease is an inflammatory reaction to microorganisms around dental implants. Due to the limited accessibility, non-invasive antimicrobial strategies are of high interest. An unexpected approach to implant disinfection may evolve from electrolysis. Given the electrical conductivity of titanium implants, alkalinity or active oxidants can be generated in body fluids. We investigated the use of dental titanium implants as electrodes for the local generation of disinfectants. Our hypothesis was that electrolysis can reduce viable counts of adhering bacteria, and that this reduction should be greater if active oxidative species are generated. Methodology/Principal Findings As model systems, dental implants, covered with a mono-species biofilm of Escherichia coli C43, were placed in photographic gelatin prepared with physiological saline. Implants were treated by a continuous current of 0 - 10 mA for 15 minutes. The reduction of viable counts was investigated on cathodes and anodes. In separate experiments, the local change in pH was visualized using color indicators embedded in the gelatin. Oxidative species were qualitatively detected by potassium iodide-starch paper. The in situ generated alkaline environment around cathodic implants caused a reduction of up to 2 orders of magnitude in viable E. coli counts. On anodic implants, in contrast to cathodic counterparts, oxidative species were detected. Here, a current of merely 7.5 mA caused complete kill of the bacteria. Conclusions/Significance This laboratory study shows that electrochemical treatment may provide access to a new way to decontaminate dental implants in situ. PMID:21264247

  11. Evaluating of bone healing around porous coated titanium implant and potential systematic bias on the traditional sampling method

    DEFF Research Database (Denmark)

    Babiker, Hassan; Ding, Ming; Overgaard, Søren

    2013-01-01

    could be affected by the various quality and quantity of bone in the local environment. Thus, implant fixation in one part might differ from the other part of the implant. This study aimed to investigate the influence of the sampling method on data evaluation. Material and methods: Titanium alloy implants...

  12. Digital X-ray stereophotogrammetry for cochlear implantation.

    Science.gov (United States)

    Wang, G; Skinner, M W; Rubinstein, J T; Howard, M A; Vannier, M W

    2000-08-01

    Multielectrode, intracochlear implant systems are effective treatment for profound sensorineural hearing loss. In some cases, these systems do not perform well, which may be partially due to variations in implant location within the cochlea. Determination of each electrode's position in a patient's inner ear provides an in vivo basis for both the cochlear modeling of electrical fields and the future design of electrode arrays that deliver electrical stimulation to surviving auditory neurons, and may improve speech processor programming for better speech recognition. We developed an X-ray stereophotogrammetric approach to localize implanted electrodes in three dimensions. Stereophotogrammetry of implanted electrodes is formulated in weak perspective geometry, with knowledge of a three-dimensional (3-D) reference structure and electrode positions in each of two digital stereo-images. The localization error is theoretically, numerically, and experimentally quantified. Both numerical and experimental results demonstrate the feasibility of the technique.

  13. Effect of ion-implantation enhanced intermixing on luminescence of InAs/InP quantum dots

    Science.gov (United States)

    Li, Q.; Barik, S.; Tan, H. H.; Jagadish, C.

    2008-10-01

    Temperature dependent photoluminescence spectra of ion implanted InAs/InP quantum dots (QDs) followed by rapid thermal annealing were studied. By employing a recently developed luminescence model for localized states ensemble, the broadening of the distribution of the localized QD states was determined from the fitting to the luminescence peak energy positions. The broadening of the distribution of the localized QD states reduces due to ion-implantation enhanced intermixing. The contribution of carrier distribution within the localized QD states to the luminescence linewidth decreases after ion-implantation enhanced intermixing. The effect of doses and types of ions used for implantation were also investigated.

  14. Effect of ion-implantation enhanced intermixing on luminescence of InAs/InP quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Li, Q; Barik, S; Tan, H H; Jagadish, C [Department of Electronic Materials Engineering, Research School of Physical Sciences and Engineering, Australian National University, Canberra 0200 (Australia)], E-mail: qing.li@anu.edu.au

    2008-10-21

    Temperature dependent photoluminescence spectra of ion implanted InAs/InP quantum dots (QDs) followed by rapid thermal annealing were studied. By employing a recently developed luminescence model for localized states ensemble, the broadening of the distribution of the localized QD states was determined from the fitting to the luminescence peak energy positions. The broadening of the distribution of the localized QD states reduces due to ion-implantation enhanced intermixing. The contribution of carrier distribution within the localized QD states to the luminescence linewidth decreases after ion-implantation enhanced intermixing. The effect of doses and types of ions used for implantation were also investigated.

  15. MnS clusters in natural zeolites

    Energy Technology Data Exchange (ETDEWEB)

    Iacomi, Felicia; Vasile, Aurelia; Polychroniadis, E.K

    2003-08-15

    FTIR, ESR, optical absorption, photoconductivity, and luminescence measurements are used to evidence the nature of MnS clusters, synthesized by treating the Mn{sup 2+} forms of natural zeolites with Na{sub 2}S.

  16. Chemokines Associated with Pathologic Responses to Orthopedic Implant Debris

    Science.gov (United States)

    Hallab, Nadim J.; Jacobs, Joshua J.

    2017-01-01

    Despite the success in returning people to health saving mobility and high quality of life, the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after approximately 15–25 years of use, due to slow progressive subtle inflammation to implant debris compromising the bone implant interface. This local inflammatory pseudo disease state is primarily caused by implant debris interaction with innate immune cells, i.e., macrophages. This implant debris can also activate an adaptive immune reaction giving rise to the concept of implant-related metal sensitivity. However, a consensus of studies agree the dominant form of this response is due to innate reactivity by macrophages to implant debris danger signaling (danger-associated molecular pattern) eliciting cytokine-based and chemokine inflammatory responses. This review covers implant debris-induced release of the cytokines and chemokines due to activation of the innate (and the adaptive) immune system and how this leads to subsequent implant failure through loosening and osteolysis, i.e., what is known of central chemokines (e.g., IL-8, monocyte chemotactic protein-1, MIP-1, CCL9, CCL10, CCL17, and CCL22) associated with implant debris reactivity as related to the innate immune system activation/cytokine expression, e.g., danger signaling (e.g., IL-1β, IL-18, IL-33, etc.), toll-like receptor activation (e.g., IL-6, tumor necrosis factor α, etc.), bone catabolism (e.g., TRAP5b), and hypoxia responses (HIF-1α). More study is needed, however, to fully understand these interactions to effectively counter cytokine- and chemokine-based orthopedic implant-related inflammation.

  17. Calix[4]arene supported clusters: a dimer of [Mn(III)Mn(II)] dimers

    DEFF Research Database (Denmark)

    Taylor, Stephanie M; McIntosh, Ruaraidh D; Beavers, Christine M;

    2011-01-01

    Phosphinate ligands allow for the transformation of a calix[4]arene supported [Mn(III)(2)Mn(II)(2)] tetramer cluster motif into an unusual [Mn(III)Mn(II)](2) dimer of dimers; the clusters self-assemble in the crystal to form bi-layer arrays reminiscent of the typical packing of calixarene solvates....

  18. Implant interactions with orthodontics.

    Science.gov (United States)

    Celenza, Frank

    2012-09-01

    Many situations arise in which orthodontic therapy in conjunction with implant modalities is beneficial, relevant or necessary. These situations might entail orthodontic treatment preparatory to the placement of an implant, such as in the site preparation for implant placement. Traditionally, this has been somewhat well understood, but there are certain guidelines that must be adhered to as well as diagnostic steps that must be followed. Provision of adequate space for implant placement is of paramount importance, but there is also the consideration of tissue manipulation and remodeling which orthodontic therapy can achieve very predictably and orthodontists should be well versed in harnessing and employing this modality of site preparation. In this way, hopeless teeth that are slated for extraction can still be utilized by orthodontic extraction to augment tissues, both hard and soft, thereby facilitating site development. On the corollary, and representing a significant shift in treatment sequencing, there are many situations in which orthodontic mechanotherapy can be simplified, expedited, and facilitated by the placement of an implant and utilization as an integral part of the mechanotherapy. Implants have proven to provide excellent anchorage, and have resulted in a new class of anchorage known as "absolute anchorage". Implants can be harnessed as anchors both in a direct and indirect sense, depending upon the dictates of the case. Further, this has led to the development of orthodontic miniscrew systems and techniques, which can have added features such as flexibility in location and placement, as well as ease of use and removal. As orthodontic appliances evolve, the advent of aligner therapy has become mainstream and well accepted, and many of the aforementioned combined treatment modalities can and should be incorporated into this relatively new treatment modality as well.

  19. Cladding of High Mn Steel on Low C Steel by Explosive Welding

    OpenAIRE

    ACARER, Mustafa

    2014-01-01

    High Mn steel containing about 16% Mn was cladded to a low C steel by explosive welding. The experimental results showed that the bonding interface has a wavy morphology; the welding interface has the characteristics of both sharp transition and local melted zones between 2 metals. Hardness increased near the welding interface due to excess plastic deformation in the explosion area and phase transformation from g (f.c.c.) to a (b.c.c.).

  20. Structural Distortion Stabilizing the Antiferromagnetic and Semiconducting Ground State of BaMn2As2

    Directory of Open Access Journals (Sweden)

    Ekkehard Krüger

    2016-09-01

    Full Text Available We report evidence that the experimentally found antiferromagnetic structure as well as the semiconducting ground state of BaMn 2 As 2 are caused by optimally-localized Wannier states of special symmetry existing at the Fermi level of BaMn 2 As 2 . In addition, we find that a (small tetragonal distortion of the crystal is required to stabilize the antiferromagnetic semiconducting state. To our knowledge, this distortion has not yet been established experimentally.

  1. The Magnetic Structure of Paramagnetic MnO

    OpenAIRE

    Paddison, Joseph A. M.; Gutmann, Matthias J.; Stewart, J. Ross; Tucker, Matthew G.; Dove, Martin T.; Keen, David A.; Goodwin, Andrew L.

    2016-01-01

    Using a combination of single-crystal neutron scattering and reverse Monte Carlo refinements, we study the magnetic structure of paramagnetic MnO at a temperature (160\\,K) substantially below the Curie-Weiss temperature $|\\theta|\\sim550$\\,K. The microscopic picture we develop reveals a locally-ordered domain structure that persists over distances many times larger than the correlation length implied by direct analysis of the spin correlation function. Moreover, the directional dependence of p...

  2. Dental implants and diabetes mellitus—a systematic review

    OpenAIRE

    Naujokat, Hendrik; Kunzendorf, Burkhard; Wiltfang, Jörg

    2016-01-01

    Dental implant surgery has developed to a widely used procedure for dental rehabilitation and is a secure and predictable procedure. Local and systemic risk factors can result in higher failure rates. Diabetes mellitus is a chronic disease that goes in with hyperglycemia and causes multifarious side effects. Diabetes as a relative contraindication for implant surgery is controversially discussed. Because the number of patients suffering from diabetes increases, there are more diabetic patient...

  3. Identification of the interstitial Mn site in ferromagnetic (Ga,Mn)As

    CERN Document Server

    AUTHOR|(CDS)2093111; Wahl, Ulrich; Augustyns, Valerie; Silva, Daniel; Granadeiro Costa, Angelo Rafael; Houben, K; Edmonds, Kevin W; Gallagher, BL; Campion, RP; Van Bael, MJ; Castro Ribeiro Da Silva, Manuel; Martins Correia, Joao; Esteves De Araujo, Araujo Joao Pedro; Temst, Kristiaan; Vantomme, André; Da Costa Pereira, Lino Miguel

    2015-01-01

    We determined the lattice location of Mn in ferromagnetic (Ga,Mn)As using the electron emission channeling technique. We show that interstitial Mn occupies the tetrahedral site with As nearest neighbors (TAs) both before and after thermal annealing at 200 °C, whereas the occupancy of the tetrahedral site with Ga nearest neighbors (TGa) is negligible. TAs is therefore the energetically favorable site for interstitial Mn in isolated form as well as when forming complexes with substitutional Mn. These results shed new light on the long standing controversy regarding TAs versus TGa occupancy of interstitial Mn in (Ga,Mn)As.

  4. Tophaceous Gout simulating infected Ankle Implants

    Directory of Open Access Journals (Sweden)

    Ioannis K

    2016-11-01

    Full Text Available Gout is a well known metabolic disorder characterized by the formation of urate crystals in joints resulting in recurrent attacks of acute inflammatory arthritis following which tophi can occur in joints or subcutaneous tissues. We report a rare localization of gouty tophi in a 52 years old male. The tophi had formed over the stainless steel implant used for the fixation of a lateral malleolus fracture 20 years ago.

  5. Positron implantation in solids

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, V.J.; Lynn, K.G.; Welch, D.O.

    1993-12-31

    The Monte Carlo technique for modeling positron prior to annihilation and electron implantation in semi-infinite metals is described. Particle implantation is modelled as a multistep process, a series of collisions with the atoms of the host material. In elastic collisions with neutral atoms there is no transfer of energy. The particle loses energy by several different channels, excitation of the electron gas, ionization of the ion cores, or, at low energies, by phonon excitation. These competing scattering mechanisms have been incorporated into the Monte Carlo framework and several different models are being used. Brief descriptions of these Monte Carlo schemes, as well as an analytic model for positron implantation are included. Results of the Monte Carlo simulations are presented and compared with expermental data. Problems associated with modeling positron implantation are discuss and the need for more expermental data on energy-loss in different materials is stressed. Positron implantation in multilayers of different metals is briefly described and extensions of this work to include a study of multilayers and heterostructures is suggested.

  6. Mn-porphyrins as novel molecular magnetic resonance imaging contrast agents.

    Science.gov (United States)

    Mouraviev, Vladimir; Venkatraman, Talaignair N; Tovmasyan, Artak; Kimura, Masaki; Tsivian, Matvey; Mouravieva, Vladimira; Polascik, Tom J; Wang, Haichen; Amrhein, Timothy J; Batinic-Haberle, Ines; Lascola, Christopher

    2011-11-03

    In this study, we investigated the potential of a new class of therapeutic Mn porphyrins as molecular MRI probes for prostate cancer imaging. Two compounds of different bioavailibility were investigated: Mn(III) meso-tetrakis(N-ethylpyridinium-2-yl)porphyrin (MnTE-2-PyP(5 +)) and Mn(III) mesotetrakis(N-n-hexylpyridinium-2-yl)porphyrin (MnTnHex-2-PyP(5 +)). These compounds have previously been shown to have adjunctive antineoplastic activity through their actions as powerful superoxide dismutase mimics, peroxynitrite scavengers, and modulators of cellular redox-based signaling pathways. Strong paramagnetic MRI contrast properties and affinity for cancer cells suggest their potential application as novel diagnostic imaging agents. MRI experiments were performed at 7.0T on a Bruker Biospec horizontal bore scanner. All in-vivo experiments were performed on 12 C57 black mice implanted with RM-9 prostate cancer cells on the hind limb. Two mg/kg of MnTnHex-2-PyP(5 +) (n = 6) and 8 mg/kg MnTE-2-PyP(5 +) (n = 6) were administered intraperitoneally 90 minutes before imaging. All the images were collected using a volume coil and processed using Paravision 4.0. Phantom studies reveal remarkably high T1 relaxivity changes for both metalloporphyrins, which are twofold to threefold higher than commercially available gadolinium chelates. Observable detection limits using conventional T1-weighted MRI are in the low micromolar range for both compounds. In vivo, MR relaxation changes in prostate tumor xenografts were readily observed after a single injection of either MnTE-2-PyP(5 +) or MnTnHex-2-PyP(5 +), with tumor contrast to background ratio greatest after MnTE-2-PyP(5 +) administration. After a single dose of MnTE-2-PyP(5 +), contrast changes in prostate tumors are up to sixfold greater than in surrounding, noncancerous tissues, suggesting the potential use of this metalloporphyrin as a novel diagnostic probe for detecting prostate malignancy using MRI.

  7. In Vitro Measurement Of Insertion Torque, Removal Torque And Resonance Frequency Analysis Of Implants Placed Into Simulated Bony Defects

    Science.gov (United States)

    2014-05-14

    K., S. Kotsovilis and I. Fourmousis (2007). "A comprehensive and critical review of dental implant prognosis in periodontally compromised partially...depend on the condition of the surrounding tissues, for example the type of local bone the implant is placed in or patient history of periodontal ...Type II or III extraction sockets, periodontal defects can be present on teeth planned for immediate implants, or peri- implant defects can occur

  8. First principles study of a new half-metallic ferrimagnets Mn{sub 2}-based full Heusler compounds: Mn{sub 2}ZrSi and Mn{sub 2}ZrGe

    Energy Technology Data Exchange (ETDEWEB)

    Abada, A. [Laboratoire d’études physico-chimiques, Université Dr Moulay Tahar, Saida 20000 (Algeria); Amara, K., E-mail: kamaraphy@gmail.com [Laboratoire d’études physico-chimiques, Université Dr Moulay Tahar, Saida 20000 (Algeria); Hiadsi, S. [Département de Génie Physique, Université d’Oran des sciences et de la technologie Mohamed Boudiaf (Algeria); Amrani, B. [Département de Physique, Université d’Oran Es-Senia, Oran 31000 (Algeria)

    2015-08-15

    Half-metallic properties of new predicted Mn{sub 2}-based full Heusler alloys Mn{sub 2}ZrSi and Mn{sub 2}ZrGe have been studied by first-principles full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). Our investigation is focused on the structural, elastic, electronic and magnetic properties of these compounds. The AlCu{sub 2}Mn-type structure is found to be energetically more favorable than the CuHg{sub 2}Ti-type structure for both compounds and are half-metallic ferrimagnets (HMFIs) with total magnetic moments of 2.000µ{sub B} per formula unit, well consistent with Slater–Pauling rule (M{sub tot}=(24–Z{sub tot})µ{sub B}). Calculations show that both the alloys have an indirect band gaps, in the majority-spin channel, with values of 0.505 eV and 0.278 eV for Mn{sub 2}ZrSi and Mn{sub 2}ZrGe, respectively. It was found that Mn{sub 2}ZrSi and Mn{sub 2}ZrGe preserved their half-metallicity for lattice constants range of 5.85–6.38 Å and 6.05–6.38 Å, respectively, and kept a 100% of spin polarization at the Fermi level. Moreover, the calculated formation energies and elastic constants confirm that these compounds are stable chemically and mechanically, and the good crystallographic compatibility with the lattice of semiconductors used industrially makes them promising magnetic materials in spintronic applications. - Highlights: • For Mn{sub 2}ZrZ (Z=Si, Ge) the AlCu{sub 2}Mn-type structure is more favorable than the CuHg{sub 2}Ti-type. • The calculated elastic constants confirm their mechanical stability. • Their negative estimated formation energies means they can be synthesized. • Their lattice constants match well with those of many semiconductor substrates. • They are predicted to be true half-metallic ferrimagnets. • The band gaps of Mn{sub 2}ZrSi~0.51 eV and Mn{sub 2}ZrGe~0.28 eV are indirect along, the Γ–X.

  9. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  10. Chronic cortical and electromyographic recordings from a fully implantable device: preclinical experience in a nonhuman primate

    Science.gov (United States)

    Ryapolova-Webb, Elena; Afshar, Pedram; Stanslaski, Scott; Denison, Tim; de Hemptinne, Coralie; Bankiewicz, Krystof; Starr, Philip A.

    2014-02-01

    Objective. Analysis of intra- and perioperatively recorded cortical and basal ganglia local field potentials in human movement disorders has provided great insight into the pathophysiology of diseases such as Parkinson's, dystonia, and essential tremor. However, in order to better understand the network abnormalities and effects of chronic therapeutic stimulation in these disorders, long-term recording from a fully implantable data collection system is needed. Approach. A fully implantable investigational data collection system, the Activa® PC + S neurostimulator (Medtronic, Inc., Minneapolis, MN), has been developed for human use. Here, we tested its utility for extended intracranial recording in the motor system of a nonhuman primate. The system was attached to two quadripolar paddle arrays: one covering sensorimotor cortex, and one covering a proximal forelimb muscle, to study simultaneous cortical field potentials and electromyography during spontaneous transitions from rest to movement. Main results. Over 24 months of recording, movement-related changes in physiologically relevant frequency bands were readily detected, including beta and gamma signals at approximately 2.5 μV/\\sqrtHz and 0.7 μV/\\sqrt{Hz}, respectively. The system architecture allowed for flexible recording configurations and algorithm triggered data recording. In the course of physiological analyses, sensing artifacts were observed (˜1 μVrms stationary tones at fixed frequency), which were mitigated either with post-processing or algorithm design and did not impact the scientific conclusions. Histological examination revealed no underlying tissue damage; however, a fibrous capsule had developed around the paddles, demonstrating a potential mechanism for the observed signal amplitude reduction. Significance. This study establishes the usefulness of this system in measuring chronic brain and muscle signals. Use of this system may potentially be valuable in human trials of chronic brain

  11. Electronic Structure and Maximum Energy Product of MnBi

    Directory of Open Access Journals (Sweden)

    Jihoon Park

    2014-08-01

    Full Text Available We have performed first-principles calculations to obtain magnetic moment, magnetocrystalline anisotropy energy (MAE, i.e., the magnetic crystalline anisotropy constant (K, and the Curie temperature (Tc of low temperature phase (LTP MnBi and also estimated the maximum energy product (BHmax at elevated temperatures. The full-potential linearized augmented plane wave (FPLAPW method, based on density functional theory (DFT within the local spin density approximation (LSDA, was used to calculate the electronic structure of LPM MnBi. The Tc was calculated by the mean field theory. The calculated magnetic moment, MAE, and Tc are 3.63 μB/f.u. (formula unit (79 emu/g or 714 emu/cm3, −0.163 meV/u.c. (or K = −0.275 × 106 J/m3 and 711 K, respectively. The (BHmax at the elevated temperatures was estimated by combining experimental coercivity (Hci and the temperature dependence of magnetization (Ms(T. The (BHmax is 17.7 MGOe at 300 K, which is in good agreement with the experimental result for directionally-solidified LTP MnBi (17 MGOe. In addition, a study of electron density maps and the lattice constant c/a ratio dependence of the magnetic moment suggested that doping of a third element into interstitial sites of LTP MnBi can increase the Ms.

  12. Dental implants: A review.

    Science.gov (United States)

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Complications in implant dentistry

    Science.gov (United States)

    Hanif, Ayesha; Qureshi, Saima; Sheikh, Zeeshan; Rashid, Haroon

    2017-01-01

    After tooth loss, an individual may seek tooth replacement so that his/her function and esthetics could be restored. Clinical prosthodontics, during the past decade, has significantly improved and developed according to the advancements in the science and patient's demands and needs. Conventional options in prosthodontics for substituting a missing single tooth include the removable partial denture, partial and full coverage bridgework, and resin-bonded bridgework. Dental implants have gained increasing popularity over the years as they are capable of restoring the function to near normal in both partial and completely edentulous arches. With substantial evidence available, fixed implant-supported prosthesis are fully acknowledged as a reliable treatment option for the replacement of single or multiple missing teeth nowadays. While dental implants are increasingly becoming the choice of replacement for missing teeth, the impediments associated with them are progressively emerging too. PMID:28435381

  14. Dental Implant Complications.

    Science.gov (United States)

    Liaw, Kevin; Delfini, Ronald H; Abrahams, James J

    2015-10-01

    Dental implants have increased in the last few decades thus increasing the number of complications. Since many of these complications are easily diagnosed on postsurgical images, it is important for radiologists to be familiar with them and to be able to recognize and diagnose them. Radiologists should also have a basic understanding of their treatment. In a pictorial fashion, this article will present the basic complications of dental implants which we have divided into three general categories: biomechanical overload, infection or inflammation, and other causes. Examples of implant fracture, loosening, infection, inflammation from subgingival cement, failure of bone and soft tissue preservation, injury to surround structures, and other complications will be discussed as well as their common imaging appearances and treatment. Lastly, we will review pertinent dental anatomy and important structures that are vital for radiologists to evaluate in postoperative oral cavity imaging.

  15. Analysis of risk factors for cluster behavior of dental implant failures.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-08-01

    Some studies indicated that implant failures are commonly concentrated in few patients. To identify and analyze cluster behavior of dental implant failures among subjects of a retrospective study. This retrospective study included patients receiving at least three implants only. Patients presenting at least three implant failures were classified as presenting a cluster behavior. Univariate and multivariate logistic regression models and generalized estimating equations analysis evaluated the effect of explanatory variables on the cluster behavior. There were 1406 patients with three or more implants (8337 implants, 592 failures). Sixty-seven (4.77%) patients presented cluster behavior, with 56.8% of all implant failures. The intake of antidepressants and bruxism were identified as potential negative factors exerting a statistically significant influence on a cluster behavior at the patient-level. The negative factors at the implant-level were turned implants, short implants, poor bone quality, age of the patient, the intake of medicaments to reduce the acid gastric production, smoking, and bruxism. A cluster pattern among patients with implant failure is highly probable. Factors of interest as predictors for implant failures could be a number of systemic and local factors, although a direct causal relationship cannot be ascertained. © 2017 Wiley Periodicals, Inc.

  16. Structural characterization of terrestrial microbial Mn oxides from Pinal Creek, AZ

    Science.gov (United States)

    Bargar, J.R.; Fuller, C.C.; Marcus, M.A.; Brearley, A.J.; Perez De la Rosa, M.; Webb, S.M.; Caldwell, W.A.

    2009-01-01

    The microbial catalysis of Mn(II) oxidation is believed to be a dominant source of abundant sorption- and redox-active Mn oxides in marine, freshwater, and subsurface aquatic environments. In spite of their importance, environmental oxides of known biogenic origin have generally not been characterized in detail from a structural perspective. Hyporheic zone Mn oxide grain coatings at Pinal Creek, Arizona, a metals-contaminated stream, have been identified as being dominantly microbial in origin and are well studied from bulk chemistry and contaminant hydrology perspectives. This site thus presents an excellent opportunity to study the structures of terrestrial microbial Mn oxides in detail. XRD and EXAFS measurements performed in this study indicate that the hydrated Pinal Creek Mn oxide grain coatings are layer-type Mn oxides with dominantly hexagonal or pseudo-hexagonal layer symmetry. XRD and TEM measurements suggest the oxides to be nanoparticulate plates with average dimensions on the order of 11 nm thick ?? 35 nm diameter, but with individual particles exhibiting thickness as small as a single layer and sheets as wide as 500 nm. The hydrated oxides exhibit a 10-?? basal-plane spacing and turbostratic disorder. EXAFS analyses suggest the oxides contain layer Mn(IV) site vacancy defects, and layer Mn(III) is inferred to be present, as deduced from Jahn-Teller distortion of the local structure. The physical geometry and structural details of the coatings suggest formation within microbial biofilms. The biogenic Mn oxides are stable with respect to transformation into thermodynamically more stable phases over a time scale of at least 5 months. The nanoparticulate layered structural motif, also observed in pure culture laboratory studies, appears to be characteristic of biogenic Mn oxides and may explain the common occurrence of this mineral habit in soils and sediments. ?? 2008 Elsevier Ltd.

  17. Alternative transarterial access for CoreValve transcatheter aortic bioprosthesis implantation.

    Science.gov (United States)

    Bruschi, Giuseppe; De Marco, Federico; Modine, Thomas; Botta, Luca; Colombo, Paola; Mauri, Silvia; Cannata, Aldo; Fratto, Pasquale; Klugmann, Silvio

    2015-05-01

    Transcatheter aortic valve implantation (TAVI) is used to treat elderly patients with severe aortic stenosis who are considered extremely high-risk surgical candidates. The safety and effectiveness of TAVI have been demonstrated in numerous studies. The self-expanding CoreValve bioprosthesis (Medtronic Inc., Minneapolis, MN, USA) was the first transcatheter aortic valve to be granted the Conformité Européene (CE) mark in May 2007 for retrograde transfemoral implantation. However, TAVI patients are also often affected by severe iliofemoral arteriopathy. In these patients, the retrograde transfemoral approach carries a high risk of vascular injury, making this approach unusable. Alternative arterial access sites, such as the subclavian artery, the ascending aorta, and the carotid artery, have been used for retrograde implantation of the CoreValve bioprosthesis. In the present report, we present the procedural considerations, risks, and benefits of the different types of arterial access used to implant the CoreValve bioprosthesis.

  18. Osseointegration of Immediate Transalveolar Implants

    Directory of Open Access Journals (Sweden)

    Yoel González Beriau

    2016-02-01

    Full Text Available Background: osseointegration is critical to start prosthetic rehabilitation. Objective: to describe osseointegration of immediate transalveolar implants. Methods: a prospective case series study was conducted from January 2012 to December 2013. It included all patients (75 patients with 79 implants who attended the Prosthodontics service. Age, sex, osseointegration, cause of tooth loss, region of the implant, specific tooth, bone level and keratinized gingiva around the implant, were the variables studied. Frequency distribution and statistical analysis were used for data analysis. Results: females and patients aged 31 to 45 years predominated. Osseointegration was observed in 97.4% of the implants. Nearly all implants were placed in the premaxilla and posterior maxilla, specifically in the first bicuspids. In most patients, osseointegration with bone formation occurred at the implant collar and in the presence of completely keratinized tissue, with a statistically significant association between the two variables. Conclusion: rehabilitation treatment with this type of implant led to successful osseointegration in most cases studied.

  19. Formation process and superparamagnetic properties of (Mn,Ga)As nanocrystals in GaAs fabricated by annealing of (Ga,Mn)As layers with low Mn content

    DEFF Research Database (Denmark)

    Sadowski, Janusz; Domagala, Jaroslaw Z.; Mathieu, Roland;

    2011-01-01

    °C) annealing of (Ga,Mn)As layers with Mn concentrations between 0.1% and 2%, grown by molecular beam epitaxy at 270°C. Decomposition of (Ga,Mn)As is already observed at the lowest annealing temperature of 400°C for layers with initial Mn content of 1% and 2%. Both cubic and hexagonal (Mn...

  20. A polyoxometalate-based single-molecule magnet with a mixed-valent {Mn(IV)2Mn(III)6Mn(II)4} core.

    Science.gov (United States)

    Zhang, Zhi-Ming; Yao, Shuang; Li, Yang-Guang; Wu, Hai-Hong; Wang, Yong-Hui; Rouzières, Mathieu; Clérac, Rodolphe; Su, Zhong-Min; Wang, En-Bo

    2013-03-28

    A polyoxometalate (POM)-based {Mn(IV)2Mn(III)6Mn(II)4} complex with single-molecule magnet (SMM) behaviour was prepared, exhibiting the largest known Mn nuclearity and the most Mn valence states in the POM-based SMM family.

  1. Spin-polarized structural, electronic, and magnetic properties of diluted magnetic semiconductors Cd(1-x)Mn(x)S and Cd(1-x)Mn(x)Se in zinc blende phase.

    Science.gov (United States)

    Nazir, S; Ikram, N; Tanveer, M; Shaukat, A; Saeed, Y; Reshak, Ali Hussain

    2009-05-21

    We studied the structural, spin-polarized electronic band structures, density of states, and magnetic properties of the diluted magnetic semiconductors (DMSs) Cd(1-x)Mn(x)S and Cd(1-x)Mn(x)Se in zinc blende phase (B3) with 25% Mn by using the ab initio method. The calculations were performed by using the full potential linearized augmented plane wave plus local orbitals (FP-L/APW+lo) method within the spin-polarized density functional theory and the local spin density approximation (LSDA). Calculated electronic band structures and the density of states of these DMSs are discussed in terms of the contribution of Mn 3d(5)4s(2), Cd 4d(10)5s(2), S 3s(2)3p(4), and Se 4s(2)4p(4) partial density of states and we also compute the local magnetic moments. We estimated the spin-exchange splitting energies, Delta(x)(d) and Delta(x)(p-d), produced by the Mn 3d states, and we found that the effective potential for the minority spin is more attractive than that for the majority spin. We determine the s-d exchange constant N(0)alpha and p-d exchange constant N(0)beta, which resembles a typical magneto-optical experiment. The calculated total magnetic moment is found to be 5.0020 and 5.00013 mu(B) for Cd(1-x)Mn(x)S and Cd(1-x)Mn(x)Se, respectively. These values indicate that every Mn impurity adds no hole carriers to the perfect CdS and CdSe crystals. Moreover, we found that p-d hybridization reduces the local magnetic moment of Mn from its free space charge value of 5.0micro(B) and produces small local magnetic moments on the nonmagnetic Cd and S sites.

  2. Exposure of implants using a modified multiple-flap transposition vestibuloplasty.

    Science.gov (United States)

    Hakim, S G; Driemel, O; Jacobsen, H C; Hermes, D; Sieg, P

    2006-12-01

    To introduce a minimally invasive operation to improve the condition of the soft tissues around the implants in an atrophied mandible, at the same time, as uncovering the implants. A multiple-flap transposition vestibuloplasty was done in 11 patients after the insertion of four implants in the interforaminal region of an atrophied mandible. Improvement in soft tissues and successful exposure of implants and attached gingiva were evaluated during a follow-up period of 55 months. All the patients were operated on local anaesthesia as outpatients. Adequate exposure of implants and an area of attached gingiva 4-9 mm wide were attained. There was no bleeding on probing or local infection. The transposition multiple-flap vestibuloplasty is a simple and minimally invasive method of improving the condition of soft tissue after insertion of implants. It does not limit the patients' routine activities and avoids staged operations.

  3. Effect of Mn Concentration on the Structural, optical and Magnetic Properties of GaMnN

    Energy Technology Data Exchange (ETDEWEB)

    Thaler, G.; Frazier, R.; Gila, B.; Stapleton, J.; Davidson, M.; Abernathy, C.R.; Pearton, S.J.; Segre, C.U. (IIT); (Florida)

    2010-11-16

    The room temperature magnetization of GaMnN films grown by molecular beam epitaxy on (0001) sapphire substrates with Mn concentrations varying from 0 to 9 at. % was found to depend on Mn concentration, with a maximum magnetization found at -3 at. % Mn. High-resolution x-ray diffraction measurements show that the c-plane lattice constant initially decreases with increasing Mn concentration, then increases when the Mn content increases above -3 at. %. This increase is accompanied by a decrease in the full width at half maximum of the rocking curves. Extended x-ray absorption fine structure results indicate that the nonsubstitutional Mn is not present in the form of Ga{sub x}Mn{sub y} clusters and thus is most likely present in the form of an interstitial. Optical absorption measurements show only a slight increase in the band gap for material with 3 at. % Mn, relative to undoped GaN.

  4. The Key to Mn Homeostasis in Plants: Regulation of Mn Transporters.

    Science.gov (United States)

    Shao, Ji Feng; Yamaji, Naoki; Shen, Ren Fang; Ma, Jian Feng

    2017-03-01

    Plants only require small amounts of manganese (Mn) for healthy growth, but Mn concentrations in soil solution vary from sub-micromolar to hundreds of micromolar across the growth period. Therefore, plants must deal with large Mn concentration fluctuations, but the molecular mechanisms underlying how plants cope with low and high Mn concentrations are poorly understood. In this Opinion we discuss the role of Mn transporters in the uptake, distribution, and detoxification of Mn in response to changes in Mn concentrations through their regulation at the transcriptional and protein levels, mainly focusing on rice, an Mn-tolerant and -accumulating species. We also propose mechanisms involved in the hyperaccumulation of Mn and future prospects for studying this specific trait. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Corrosion of bio implants

    Indian Academy of Sciences (India)

    U Kamachi Mudali; T M Sridhar; Baldev Raj

    2003-06-01

    Chemical stability, mechanical behaviour and biocompatibility in body fluids and tissues are the basic requirements for successful application of implant materials in bone fractures and replacements. Corrosion is one of the major processes affecting the life and service of orthopaedic devices made of metals and alloys used as implants in the body. Among the metals and alloys known, stainless steels (SS), Co–Cr alloys and titanium and its alloys are the most widely used for the making of biodevices for extended life in human body. Incidences of failure of stainless steel implant devices reveal the occurrence of significant localised corroding viz., pitting and crevice corrosion. Titanium forms a stable TiO2 film which can release titanium particles under wear into the body environment. To reduce corrosion and achieve better biocompatibility, bulk alloying of stainless steels with titanium and nitrogen, surface alloying by ion implantation of stainless steels and titanium and its alloys, and surface modification of stainless steel with bioceramic coatings are considered potential methods for improving the performance of orthopaedic devices. This review discusses these issues in depth and examines emerging directions.

  6. Ion implantation in polymers

    Science.gov (United States)

    Wintersgill, M. C.

    1984-02-01

    An introductory overview will be given of the effects of ion implantation on polymers, and certain areas will be examined in more detail. Radiation effects in general and ion implantation in particular, in the field of polymers, present a number of contrasts with those in ionic crystals, the most obvious difference being that the chemical effects of both the implanted species and the energy transfer to the host may profoundly change the nature of the target material. Common effects include crosslinking and scission of polymer chains, gas evolution, double bond formation and the formation of additional free radicals. Research has spanned the chemical processes involved, including polymerization reactions achievable only with the use of radiation, to applied research dealing both with the effects of radiation on polymers already in commercial use and the tailoring of new materials to specific applications. Polymers are commonly divided into two groups, in describing their behavior under irradiation. Group I includes materials which form crosslinks between molecules, whereas Group II materials tend to degrade. In basic research, interest has centered on Group I materials and of these polyethylene has been studied most intensively. Applied materials research has investigated a variety of polymers, particularly those used in cable insulation, and those utilized in ion beam lithography of etch masks. Currently there is also great interest in enhancing the conducting properties of polymers, and these uses would tend to involve the doping capabilities of ion implantation, rather than the energy deposition.

  7. Implantable Impedance Plethysmography

    OpenAIRE

    2014-01-01

    We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.

  8. Remote actuated valve implant

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  9. Semiconductor Ion Implanters

    Science.gov (United States)

    MacKinnon, Barry A.; Ruffell, John P.

    2011-06-01

    In 1953 the Raytheon CK722 transistor was priced at 7.60. Based upon this, an Intel Xeon Quad Core processor containing 820,000,000 transistors should list at 6.2 billion! Particle accelerator technology plays an important part in the remarkable story of why that Intel product can be purchased today for a few hundred dollars. Most people of the mid twentieth century would be astonished at the ubiquity of semiconductors in the products we now buy and use every day. Though relatively expensive in the nineteen fifties they now exist in a wide range of items from high-end multicore microprocessors like the Intel product to disposable items containing `only' hundreds or thousands like RFID chips and talking greeting cards. This historical development has been fueled by continuous advancement of the several individual technologies involved in the production of semiconductor devices including Ion Implantation and the charged particle beamlines at the heart of implant machines. In the course of its 40 year development, the worldwide implanter industry has reached annual sales levels around 2B, installed thousands of dedicated machines and directly employs thousands of workers. It represents in all these measures, as much and possibly more than any other industrial application of particle accelerator technology. This presentation discusses the history of implanter development. It touches on some of the people involved and on some of the developmental changes and challenges imposed as the requirements of the semiconductor industry evolved.

  10. Implantable Impedance Plethysmography

    Directory of Open Access Journals (Sweden)

    Michael Theodor

    2014-08-01

    Full Text Available We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.

  11. Hip Resurfacing Implants.

    Science.gov (United States)

    Cadossi, Matteo; Tedesco, Giuseppe; Sambri, Andrea; Mazzotti, Antonio; Giannini, Sandro

    2015-08-01

    EDUCATIONAL OBJECTIVES As a result of reading this article, physicians should be able to: 1. Describe the advantages of hip resurfacing. 2. Describe the disadvantages of hip resurfacing. 3. Identify the population in which hip resurfacing is most often indicated. 4. Demonstrate how to properly postoperatively manage patients with metal-on-metal prostheses. Hip resurfacing offers a suitable solution for young patients affected by hip disease who have high function demands and good bone quality. Bone stock preservation, restoration of the normal proximal femur anatomy, the lack of stress shielding, and the possibility of resuming sporting activity are proven advantages of hip resurfacing. However, there are some disadvantages, such as fracture of the femoral neck, onset of neck narrowing, and possible complications due to the metal-on-metal bearings, including pseudotumors, peri-implant osteolysis, and chronic elevation of metal ions in serum levels. Recent data suggest that the ideal candidate for hip resurfacing is an active male, younger than 65 years, with primary or posttraumatic osteoarthritis, and with a femoral head diameter larger than 50 to 54 mm. Based on these selection criteria, the literature reports implant survival to be similar to that of total hip arthroplasty. The current authors' experience confirms a low failure rate and excellent functional outcomes, with metal ion serum levels becoming stable over time in well-functioning implants. Proper surgical technique, correct patient selection, and the right choice of a well-established prosthetic model are essential elements for the long-term success of these implants.

  12. Cochlear Implants (For Parents)

    Science.gov (United States)

    ... a few days About 2 to 4 weeks after surgery, the sound and speech processor is matched with the implant package and ... of these sounds and will quickly learn language. After the first few ... sounds and develop speech and language. This is an extended process with ...

  13. Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    Science.gov (United States)

    Akça, Kıvanç; Eser, Atılım; Çavuşoğlu, Yeliz; Sağırkaya, Elçin; Çehreli, Murat Cavit

    2015-05-01

    The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium-zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface. Under axial loading, principal stresses in both models were comparable for both implants and models. Under oblique loading, principal stresses around titanium-zirconium implants were slightly higher in both models. Comparable stress magnitudes were observed in both models. The displacement values and equivalent strain amplitudes around both implants and models were similar. Peri-implant bone around titanium and titanium-zirconium implants experiences similar stress magnitudes coupled with intraosseous implant displacement values under conventional loading and early loading simulations. Titanium-zirconium implants have biomechanical outcome comparable to conventional titanium implants under conventional loading and early loading.

  14. Atom probe tomography study of GaMnN thin films

    Energy Technology Data Exchange (ETDEWEB)

    Nicholas, Robert; Kane, Matthew [School of Electrical and Computer Engineering, University of Oklahoma, 110 W Boyd St Rm 150, Norman, OK 73019 (United States); Diercks, David [Center for Advanced Research and Technology, University of North Texas, Denton, TX 76203 (United States)

    2012-03-15

    Determining the nanoscale atomic distribution of transition metals is essential for understanding the magnetic behavior of III-nitride semiconductors. Atom probe tomography is a characterization technique that can provide direct physical detection of the location of atoms and thus is ideal for investigating nanoscale atomic ordering in these materials. This work presents a study of GaMnN thin films grown bymetalorganic chemical vapor deposition that are characterized utilizing the state of the art local electrode atom probe (LEAP trademark) to determine the atomic ordering of Mn in an effort to help understand the nanoclustering behaviour which leads to observed room-temperature ferromagnetic behaviour in GaMnN. The distribution of Mn on the atomic scale was found to be random in nature in the bulk of the thin film where the analysis was performed with no evidence for the predisposition of Mn to form dimers, trimers or clusters. Other sources of clustering must lead to the room-temperature ferromagnetic behaviour that has been observed in these samples, such as surface segregation of Mn during the growth process. This work proves consistent with prior magnetic analysis in that most atoms in the crystal are isolated Mn atoms which result in a paramagnetic signal. This work is a first step towards the ultimate goal of understanding the structure-property-growth condition relationships for the tailoring of specific MOCVD processes in nitride semiconductors. (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Effect of carbon content on magnetostructural properties of Mn{sub 3}GaC

    Energy Technology Data Exchange (ETDEWEB)

    Dias, E.T. [Department of Physics, Goa University, Goa 403206 (India); Priolkar, K.R., E-mail: krp@unigoa.ac.in [Department of Physics, Goa University, Goa 403206 (India); Nigam, A.K. [Tata Institute of Fundamental Research, Dr. Homi Bhabha Road, Colaba, Mumbai 400005 (India)

    2014-08-01

    Effect of carbon content on magnetostructural transformation in antiperovskites of the type Mn{sub 3}GaC{sub x} (x=0.8, 1.0 and 1.05) has been investigated. It is found that increase in carbon content changes the ground state from ferromagnetic metallic (x=0.8) to antiferromagnetic semiconducting (x=1.05) type. This has been attributed to localization of itinerant Mn 3d electrons due to increased Mn3d – C2p hybridization. Such a hybridization strengthens Mn–C–Mn antiferromagnetic interactions over Mn–Mn ferromagnetic interactions. Further, magnetic field can be used as a tool to modulate the relative strengths of these ferromagnetic and antiferromagnetic interactions thereby affecting the nature and strength of magnetocaloric properties. - Highlights: • Effect of carbon content on magnetostructural transformation in Mn{sub 3}GaC{sub x} has been investigated. • Increase in C content changes the ground state from FM metallic to AFM semiconducting type. • This behavior can be understood to be due to increased Mn3d – C2p hybridization • Magnetic field can be used to modulate the relative strengths of competing magnetic interactions.

  16. Structural; morphological; optical and magnetic properties of Mn doped ferromagnetic ZnO thin film

    Science.gov (United States)

    Karmakar, R.; Neogi, S. K.; Banerjee, Aritra; Bandyopadhyay, S.

    2012-12-01

    The structural, optical and magnetic properties of the Zn1-xMnxO (0 disorder developed in the samples due to Mn doping. The films are of single phase in nature; no formation of any secondary phase has been detected from structural analysis. Absence of magnetic impurity phase in these films has been confirmed from morphological study also. Increasing tendency of lattice parameters and unit cell volume has been observed with increasing Mn doping concentration. The incorporation of Mn2+ ions introduces disorder in the system. That also leads to slight degradation in crystalline quality of the films with increasing doping. The grain size reduces with increase in Mn doping proportion. The band gaps shows red shift with doping and the width of localized states shows an increasing tendency with doping concentration. It is due to the formation of impurity band and trapping of Mn atoms, which leads to the generation of the defect states within the forbidden band. Photoluminescence (PL) spectra show gradual decrease of intensity of exitonic and defect related peaks with increasing Mn doping. Defect mediated intrinsic ferromagnetism has been observed even at room temperature for 5 at% Mn doped ZnO film. The strong presence of antiferromagnetic (AFM) interaction reduces the observed ferromagnetic moments.

  17. Manganese-induced reactive oxygen species: comparison between Mn+2 and Mn+3.

    Science.gov (United States)

    Ali, S F; Duhart, H M; Newport, G D; Lipe, G W; Slikker, W

    1995-09-01

    Manganese (Mn) is an essential element, the deficiency or excess of which is known to cause neurotoxicity in experimental animals and man. The mechanism of action of Mn neurotoxicity is still unclear. The present study was designed to evaluate whether in vitro or in vivo exposure to Mn produced reactive oxygen species (ROS). We also sought to determine if a single injection of Mn produces changes in monoamines concentration in different regions of rat brain. Adult Sprague-Dawley rats were dosed with 0, 50 or 100 mg/kg, ip with either MnCl2 (Mn+2) or MnOAc (Mn+3) and were sacrificed 1 h after the dose was administered. Brains were quickly removed and dissected for neurochemical analysis. ROS were measured by a molecular probe, 2',7'-dichlorofluorescein diacetate (DCFH-DA), and monoamines and their metabolites were measured by HPLC/EC. In vitro exposure to MnCl2 (1-1000 microM) produced dose-dependent increases of ROS in striatum whereas MnOAc produced similar increases at much lower concentrations (1-100 microM). In vivo exposure to MnOAc (Mn+3) produced significant increases of ROS in caudate nucleus and hippocampus, whereas MnCl2 (Mn+2) produced significant effects only in hippocampus. Concentrations of dopamine, serotonin and their metabolites (DOPAC, HVA and 5-HIAA) were not altered with acute injections of either MnCl2 or MnOAc. These data suggest that both divalent and trivalent manganese induce ROS, however, Mn+3 is an order of magnitude more potent than Mn+2.

  18. Comparative study of the Mn4+2E → 4A2 luminescence in isostructural RE2Sn2O7:Mn4+ pyrochlores (RE3+ = Y3+, Lu3+ or Gd3+)

    Science.gov (United States)

    Senden, Tim; Broers, Fréderique T. H.; Meijerink, Andries

    2016-10-01

    Red emitting Mn4+-doped crystalline materials have potential for application in light emitting devices and therefore it is important to understand how the optical properties of Mn4+ are influenced by the host lattice the Mn4+ ions are situated in. In this work we investigate the effect of the host cations in the second coordination sphere on the Mn4+ emission by studying the luminescence of Mn4+ ions doped into three isostructural rare earth (RE) stannate RE2Sn2O7 pyrochlores (RE3+ = Y3+, Lu3+ or Gd3+). It is found that the energies of the Mn4+4T1 and 4T2 states significantly increase with decreasing Mn4+-O2- distance, whereas the energy of the 2E level shows a small shift to higher energies from RE3+ = Gd3+ to Lu3+ to Y3+. The observed trend for the 2E level energy is not related to the size of the RE3+ ion and is not in line with theoretical calculations reported previously. Low temperature emission spectra of the RE2Sn2O7:Mn4+ phosphors reveal that only asymmetrical vibronic modes couple to the 2E → 4A2 transition and furthermore show there is significant and unexpected local disorder for Mn4+ in Gd2Sn2O7 that is not observed for Mn4+ in the other hosts. Photoluminescence decay measurements demonstrate that the luminescence of RE2Sn2O7:Mn4+ is strongly quenched below room temperature which is assigned to non-radiative relaxation via a low-lying O2- → Mn4+ charge-transfer state.

  19. XANES study of Fe-implanted strontium titanate

    Science.gov (United States)

    Lobacheva, O.; Goncharova, L. V.; Chavarha, M.; Sham, T. K.

    2014-03-01

    Properties of strontium titanate SrTiO3 (STO) depend to a great extent on the substitutional dopants and defects of crystal structure. The ion beam implantation method was used for doping STO (001) crystals with Fe at different doses. Implanted samples were then annealed at 350°C in oxygen to induce recrystallization and remove oxygen vacancies produced during ion implantation process. The effect of Fe doping and post-implantation annealing was studied by X-ray Absorption Near Edge Spectroscopy (XANES) method and Superconducting Quantum Interference Device (SQUID). XANES allowed to monitor the change in structure of STO crystals and in the local environment of Fe following the implantation and annealing steps. SQUID measurements revealed correlation between magnetic moment and Fe implantation dose. Ferromagnetic hysteresis was observed on selected Fe-implanted STO at 5 K. The observed magnetic properties can be correlated with the several Fe oxide phases in addition to the presence of O/Ti vacancies.

  20. Remote electrical stimulation by means of implanted rectifiers.

    Directory of Open Access Journals (Sweden)

    Antoni Ivorra

    Full Text Available Miniaturization of active implantable medical devices is currently compromised by the available means for electrically powering them. Most common energy supply techniques for implants--batteries and inductive couplers--comprise bulky parts which, in most cases, are significantly larger than the circuitry they feed. Here, for overcoming such miniaturization bottleneck in the case of implants for electrical stimulation, it is proposed to make those implants act as rectifiers of high frequency bursts supplied by remote electrodes. In this way, low frequency currents will be generated locally around the implant and these low frequency currents will perform stimulation of excitable tissues whereas the high frequency currents will cause only innocuous heating. The present study numerically demonstrates that low frequency currents capable of stimulation can be produced by a miniature device behaving as a diode when high frequency currents, neither capable of thermal damage nor of stimulation, flow through the tissue where the device is implanted. Moreover, experimental evidence is provided by an in vivo proof of concept model consisting of an anesthetized earthworm in which a commercial diode was implanted. With currently available microelectronic techniques, very thin stimulation capsules (diameter <500 µm deliverable by injection are easily conceivable.

  1. Atypical Case of Three Dental Implants Displaced into the Maxillary Sinus

    Directory of Open Access Journals (Sweden)

    João Felipe Bonatto Bruniera

    2015-01-01

    Full Text Available Oral rehabilitation with dental implants has become a routine treatment in contemporary dentistry. The displacement of dental implants into the sinus membrane, a complication related to the maxillary sinus, is one of the most common accidents reported in the literature. The treatment for this complication is the surgical removal of the implant. A 60-year-old woman with three dental implants displaced into the maxillary sinus (one implant displaced into the left maxillary sinus and two implants displaced into the right maxillary sinus underwent surgery for removal of the implants. The surgery to remove the implants was performed under local anesthesia through the Caldwell-Luc technique. The patient was subsequently administered antibiotic, anti-inflammatory, and analgesic drugs. The patient returned 7 days after the surgery for suture removal and is being regularly monitored to determine whether future rehabilitation of the edentulous area is necessary. In conclusion, surgical removal of the dental implant displaced into the maxillary sinus is the treatment of choice. This technique is appropriate because it allows the use of local anesthesia and provides direct visualization for the removal of the implants.

  2. Thermodynamics of the Mn-P system

    Science.gov (United States)

    Lee, Y. E.

    1986-12-01

    The free energy of mixing in the Mn-P melts in the composition range of X p = 0.0 to 0.333 was estimated by coupling the phase boundary information with reliable Δ G° formation for the Mn2P phase. This information was used to obtain the dilute solution properties of P in Mn. P( l,pure) = P( l,Henrian, Mn) Δ G °(Joules) = -203,611.39 + 41.003 T The free energy is shown to be more negative than in the Fe system, reflecting a stronger interaction between Mn and P atoms than between Fe and P atoms. Presenting the activity coefficient of P with the expression used by Lupis and Elliott, the first and second interaction coefficients are obtained as follows: ɛ{P/P}(Mn) = 10.538 + 9728.14/ T ρ{P/P}(Mn) = 28.148 + 9101.83/ T The Gibbs free energy of formation for Mn3P was estimated in the temperature range of {dy1233} to {dy1378} K to be 3Mn l + P( l = Mn3P( s Δ G °(Joules) = -241,461.65 + 65.031 T

  3. Precipitation hardening of biodegradable Fe-Mn-Pd alloys

    Energy Technology Data Exchange (ETDEWEB)

    Moszner, F. [Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich (Switzerland); Sologubenko, A.S. [Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich (Switzerland); Laboratory for Nanometallurgy, Department of Materials, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich (Switzerland); Schinhammer, M. [Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich (Switzerland); Lerchbacher, C. [Christian Doppler Laboratory for Early Stages of Precipitation, University of Leoben, Franz-Josef-Strasse 18, 8700 Leoben (Austria); Haenzi, A.C. [Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich (Switzerland); Leitner, H. [Christian Doppler Laboratory for Early Stages of Precipitation, University of Leoben, Franz-Josef-Strasse 18, 8700 Leoben (Austria); Uggowitzer, P.J. [Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich (Switzerland); Loeffler, J.F., E-mail: joerg.loeffler@mat.ethz.ch [Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich (Switzerland)

    2011-02-15

    This work presents a phenomenological description of the precipitation controlled hardening of a new biodegradable Fe-based alloy developed to fulfill the requirements of temporary implant applications. Pronounced strengthening of the solution-treated martensitic Fe-10Mn-1Pd (in wt.%) alloy upon isothermal aging at temperatures within the ferrite-austenite phase field is observed and attributed to the thermally activated formation of coherent plate-like Pd-rich precipitates on {l_brace}1 0 0{r_brace} planes of the matrix. The onset and the early stages of alloy decomposition were studied using two complementary techniques: transmission electron microscopy and three-dimensional atom probe analysis. Three distinct regions of the hardening kinetics are recognized and closely correlated to the evolution of the alloy microstructure. Upon aging, clustering of Pd atoms within the Fe-Mn solid solution occurs. The very small clusters grow, coarsen and adopt a plate-like shape, rearranging mutually to reduce the overall elastic strain energy. The elastic interaction of the dislocation substructure with Pd-rich precipitates of evolving morphology affects the dislocation mobility and is responsible for the hardness evolution of the alloy. A study of the hardening kinetics shows that the process exhibits all the features characteristic of maraging steels.

  4. Antibacterial Surface Treatment for Orthopaedic Implants

    Directory of Open Access Journals (Sweden)

    Jiri Gallo

    2014-08-01

    Full Text Available It is expected that the projected increased usage of implantable devices in medicine will result in a natural rise in the number of infections related to these cases. Some patients are unable to autonomously prevent formation of biofilm on implant surfaces. Suppression of the local peri-implant immune response is an important contributory factor. Substantial avascular scar tissue encountered during revision joint replacement surgery places these cases at an especially high risk of periprosthetic joint infection. A critical pathogenic event in the process of biofilm formation is bacterial adhesion. Prevention of biomaterial-associated infections should be concurrently focused on at least two targets: inhibition of biofilm formation and minimizing local immune response suppression. Current knowledge of antimicrobial surface treatments suitable for prevention of prosthetic joint infection is reviewed. Several surface treatment modalities have been proposed. Minimizing bacterial adhesion, biofilm formation inhibition, and bactericidal approaches are discussed. The ultimate anti-infective surface should be “smart” and responsive to even the lowest bacterial load. While research in this field is promising, there appears to be a great discrepancy between proposed and clinically implemented strategies, and there is urgent need for translational science focusing on this topic.

  5. Antibacterial surface treatment for orthopaedic implants.

    Science.gov (United States)

    Gallo, Jiri; Holinka, Martin; Moucha, Calin S

    2014-08-11

    It is expected that the projected increased usage of implantable devices in medicine will result in a natural rise in the number of infections related to these cases. Some patients are unable to autonomously prevent formation of biofilm on implant surfaces. Suppression of the local peri-implant immune response is an important contributory factor. Substantial avascular scar tissue encountered during revision joint replacement surgery places these cases at an especially high risk of periprosthetic joint infection. A critical pathogenic event in the process of biofilm formation is bacterial adhesion. Prevention of biomaterial-associated infections should be concurrently focused on at least two targets: inhibition of biofilm formation and minimizing local immune response suppression. Current knowledge of antimicrobial surface treatments suitable for prevention of prosthetic joint infection is reviewed. Several surface treatment modalities have been proposed. Minimizing bacterial adhesion, biofilm formation inhibition, and bactericidal approaches are discussed. The ultimate anti-infective surface should be "smart" and responsive to even the lowest bacterial load. While research in this field is promising, there appears to be a great discrepancy between proposed and clinically implemented strategies, and there is urgent need for translational science focusing on this topic.

  6. Influence of magnetic on ferroelectric ordering in LuMnO3

    Science.gov (United States)

    van Aken, Bas B.; Palstra, Thomas T.

    2004-04-01

    We have studied the influence of antiferromagnetic ordering on the local dielectric moments of the MnO5 and LuO7 polyhedra by measuring neutron powder-diffraction patterns of LuMnO3 at temperatures near TN. We show that the coupling is weak, because the magnetic exchange coupling is predominantly in the ab plane of the MnO5 trigonal bipyramids, and the electric dipole moments, originating in the LuO7 polyhedra, are oriented along the hexagonal c axis. Anomalies in the dielectric properties near TN are thus caused by the geometric constraints between the MnO5 and the LuO7 polyhedra.

  7. Modeling and Characterization of the Magnetocaloric Effect in Ni2MnGa Materials

    Energy Technology Data Exchange (ETDEWEB)

    Nicholson, Don M [ORNL; Odbadrakh, Khorgolkhuu [ORNL; Rios, Orlando [ORNL; Hodges, Jason P [ORNL; Ludtka, Gerard Michael [ORNL; Porter, Wallace D [ORNL; Sefat, Athena Safa [ORNL; Rusanu, Aurelian [ORNL; Evans III, Boyd Mccutchen [ORNL

    2012-01-01

    Magnetic shape memory alloys have great promise as magneto-caloric effect refrigerant materials due to their combined magnetic and structural transitions. Computational and experimental research is reported on the Ni2MnGa material system. The magnetic states of this system have been explored using the Wang-Landau statistical approach in conjunction with the Locally Self-consistent Multiple-Scattering (LSMS) method to explore the magnetic states responsible for the magnet-caloric effect in this material. The effects of alloying agents on the transition temperatures of the Ni2MnGa alloy were investigated using differential scanning calorimetry (DSC) and superconducting quantum interference device (SQUID). Neutron scattering experiments were performed to observe the structural and magnetic phase transformations at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) on alloys of Ni-Mn-Ga and Ni-Mn-Ga-Cu-Fe. Data from the observations are discussed in comparison with the computational studies.

  8. Excitations and magnetization density distribution in the dilute ferromagnetic semiconductor Yb14MnSb11

    Science.gov (United States)

    Stone, M. B.; Garlea, V. O.; Gillon, B.; Cousson, A.; Christianson, A. D.; Lumsden, M. D.; Nagler, S. E.; Mandrus, D.; Sales, B. C.

    2017-01-01

    Yb14MnSb11 is a rare example of a Kondo lattice compound with ferromagnetic dominated RKKY interactions. As a ferromagnetic semiconductor with Tc≈53 K, it is also a potential compound for exploration of spintronic devices. Here we describe measurements which answer remaining questions regarding the energy scales of the exchange interactions, the valence, and the magnetization density distribution in this system. We find that the system consists of RKKY exchange coupled Mn2 + sites with nearest and next nearest exchange interactions dominating the magnetic spectrum with no significant magnetization density localized on other atomic sites. The extended spread of a negative magnetization around each of the Mn ions supports a Kondo screening cloud scenario for Yb14MnSb11 .

  9. Engineered porous metals for implants

    Science.gov (United States)

    Vamsi Krishna, B.; Xue, Weichang; Bose, Susmita; Bandyopadhyay, Amit

    2008-05-01

    Interest is significant in patient-specific implants with the possibility of guided tissue regeneration, particularly for load-bearing implants. For such implants to succeed, novel design approaches and fabrication technologies that can achieve balanced mechanical and functional performance in the implants are necessary. This article is focused on porous load-bearing implants with tailored micro-as well as macrostructures using laser-engineered net shaping (LENS™), a solid freeform fabrication or rapid prototyping technique that can be used to manufacture patient-specific implants. This review provides an insight into LENS, some properties of porous metals, and the potential applications of this process to fabricate unitized structures which can eliminate longstanding challenges in load-bearing implants to increase their in-vivo lifetime, such as in a total hip prosthesis.

  10. Percutaneous breast implant herniation: a rare complication of miliary TB.

    Science.gov (United States)

    Dale, Adam P; Dedicoat, Martin J; Saleem, Tausif; Moran, Ed

    2015-01-07

    We describe the case of a 46-year-old female patient treated for disseminated tuberculosis (TB) infection involving the lungs, urinary tract and skin. Following initiation of antituberculous therapy, the patient's right breast implant eroded through the overlying skin and was seen to be herniating through the resulting defect. The breast implant was removed under local anaesthetic and histological analysis of the resected tissue demonstrated granuloma formation consistent with periprosthetic TB. Wound healing following implant removal was poor and future breast augmentation surgery was only considered following completion of 12 months anti-TB treatment. This case constitutes the first report in the literature of percutaneous breast implant herniation resulting from periprosthetic infection with TB. A high index of suspicion is required to ensure early detection and timely management of TB and, in cases where periprosthetic pus aspirate is sterile, mycobacterial infection must be actively excluded. 2015 BMJ Publishing Group Ltd.

  11. First-principles study of the electronic and magnetic properties of Fe{sub 2}MnAl, Fe{sub 2}MnSi and Fe{sub 2}MnSi{sub 0.5}Al{sub 0.5}

    Energy Technology Data Exchange (ETDEWEB)

    Belkhouane, M. [Laboratoire d' Étude des Matériaux and Instrumentations Optiques, Département de Physique, Faculté des Sciences Exactes, Université de Sidi Bel Abbès, Sidi Bel Abbès 22000 (Algeria); Amari, S. [Modeling and Simulation in Materials Science Laboratory, Physics Department, University of Sidi Bel-Abbes, Sidi Bel-Abbes (Algeria); Yakoubi, A. [Laboratoire d' Étude des Matériaux and Instrumentations Optiques, Département de Physique, Faculté des Sciences Exactes, Université de Sidi Bel Abbès, Sidi Bel Abbès 22000 (Algeria); Tadjer, A.; Méçabih, S. [Modeling and Simulation in Materials Science Laboratory, Physics Department, University of Sidi Bel-Abbes, Sidi Bel-Abbes (Algeria); Murtaza, G., E-mail: murtaza@icp.edu.pk [Materials Modeling Laboratory, Department of Physics, Islamia College University, Peshawar (Pakistan); Bin Omran, S. [Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451 (Saudi Arabia); Khenata, R., E-mail: khenata_rabah@yahoo.fr [LPQ3M Laboratory, Institute of Science and Technology, University of Mascara, 2900 (Algeria)

    2015-03-01

    In this work, first-principles calculations of the structural, electronic and magnetic properties of Heusler compounds Fe{sub 2}MnAl, Fe{sub 2}MnSi and alloy Fe{sub 2}MnSi{sub 0.5}Al{sub 0.5} are presented. We have applied the full-potential linearized augmented plane waves plus local orbitals (FP-L/APW+lo) method based on the density functional theory (DFT). For the exchange and correlation potential the generalized-gradient approximation (GGA) is used. It is shown that the calculated lattice constants and spin magnetic moments are in good agreement with the available theoretical and experimental data. The calculated atomic resolved densities of states of Fe{sub 2}MnAl, Fe{sub 2}MnSi indicate half-metallic behavior with vanishing electronic density of states for minority spin at the Fermi level, which yields perfect spin polarization while for Fe{sub 2}MnSi{sub 0.5}Al{sub 0.5} shows nearly half-metallic behavior with small spin-down electronic density of states at the Fermi level. - Highlights: • FP-L/APW+lo method, within generalized-gradient approximation have been applied • The structural, electronic and magnetic properties of Fe{sub 2}MnAl, Fe{sub 2}MnSi and Fe{sub 2}MnSi{sub 0.5}Al{sub 0.5} are studied • Our calculated lattice constants and spin magnetic moments are in good agreement with the available theoretical and experimental data • Fe{sub 2}MnAl, Fe{sub 2}MnSi are half-metals and Fe{sub 2}MnSi{sub 0.5}Al{sub 0.5} nearly half-metals.

  12. XPS Determination of Mn Oxidation States in Mn (Hydr)oxides

    Energy Technology Data Exchange (ETDEWEB)

    Ilton, Eugene S.; Post, Jeffrey E.; Heaney, Peter J.; Ling, Florence T.; Kerisit, Sebastien N.

    2016-03-15

    Hydrous manganese oxides are an important class of minerals that help regulate the geochemical redox cycle in near-surface environments and are also considered to be promising catalysts for energy applications such as the oxidation of water. A complete characterization of these minerals is required to better understand their catalytic activity. In this contribution an empirical methodology using X-ray photoelectron spectroscopy (XPS) is developed to quantify the oxidation state of hydrous multivalent manganese oxides with an emphasis on birnessite, a common layered structure that occurs readily in Nature but is also the oxidized endmember in biomimetic water-oxidation catalysts. The Mn2p3/2, Mn3p, and Mn3s lines of near monovalent Mn(II), Mn(III), and Mn(IV) oxides were fit with component peaks; after the best fit was obtained the relative widths, heights and binding energies of the components were fixed. Unknown multivalent samples were fit such that binding energies, intensities, and widths of each oxidation state, composed of a packet of correlated component peaks, were allowed vary. whereas widths were constrained to maintain the difference between the standards. Both average and individual mole fraction oxidation states for all three energy levels were strongly correlated with close agreement between Mn3s and Mn3p, whereas Mn2p3/2 gave systematically more reduced results. Limited stoichiometric analyses were consistent with Mn3p and Mn3s. Further, evidence indicates the shape of the Mn3p line was less sensitive to the bonding environment than Mn2p. Consequently, fitting the Mn3p and Mn3s lines yields robust quantification of oxidation states over a range of hydrous Mn oxide polytypes and compositions. In contrast, a common method for determining oxidation states that utilizes the multiplet splitting of the Mn3s line is not appropriate for birnessites.

  13. Surface modification of traditional and bioresorbable metallic implant materials for improved biocompatibility

    Science.gov (United States)

    Walker, Emily K.

    Due to their strength, elasticity, and durability, a variety of metal alloys are commonly used in medical implants. Traditionally, corrosion-resistant metals have been preferred. These permanent materials can cause negative systemic and local tissue effects in the long-term. Permanent stenting can lead to late-stent thrombosis and in-stent restenosis. Metallic pins and screws for fracture fixation can corrode and fail, cause loss of bone mass, and contribute to inflammation and pain at the implant site, requiring reintervention. Corrodible metallic implants have the potential to prevent many of these complications by providing transient support to the affected tissue, dissolving at a rate congruent with the healing of the tissue. Alloys of iron and manganese (FeMn) exhibit similar fatigue strength, toughness, and elasticity compared with 316L stainless steel, making them very attractive candidates for bioresorbable stents and temporary fracture fixation devices. Much attention in recent years has been given to creating alloys with ideal mechanical properties for various applications. Little work has been done on determining the blood compatibility of these materials or on examining how their surfaces can be improved to improve cell adhesion, however. We examined thethrombogenic response of blood exposed to various resorbable ferrous stent materials through contact with porcine blood. The resorbable materials induced comparable or lower levels of several coagulation factors compared with 316L stainless steel. Little platelet adhesion was observed on any of the tested materials. Endothelialization is an important process after the implantation of a vascular stent, as it prevents damage to the vessel wall that can accelerate neointimal hyperplasia. Micromotion can lead to the formation of fibrous tissue surrounding an orthopedic implant, loosening, and ultimately failure of the implant. Nanoscale features were created on the surfaces of noble metal coatings, silicon

  14. Oxygen Isotope Evidence for Mn(II)-Catalyzed Recrystallization of Manganite (γ-MnOOH).

    Science.gov (United States)

    Frierdich, Andrew J; Spicuzza, Michael J; Scherer, Michelle M

    2016-06-21

    Manganese is biogeochemically cycled between aqueous Mn(II) and Mn(IV) oxides. Aqueous Mn(II) often coexists with Mn(IV) oxides, and redox reactions between the two (e.g., comproportionation) are well known to result in the formation of Mn(III) minerals. It is unknown, however, whether aqueous Mn(II) exchanges with structural Mn(III) in manganese oxides in the absence of any mineral transformation (similar to what has been reported for aqueous Fe(II) and some Fe(III) minerals). To probe whether atoms exchange between a Mn(III) oxide and water, we use a (17)O tracer to measure oxygen isotope exchange between structural oxygen in manganite (γ-MnOOH) and water. In the absence of aqueous Mn(II), about 18% of the oxygen atoms in manganite exchange with the aqueous phase, which is close to the estimated surface oxygen atoms (∼11%). In the presence of aqueous Mn(II), an additional 10% (for a total of 28%) of the oxygen atoms exchange with water, suggesting that some of the bulk manganite mineral (i.e., beyond surface) is exchanging with the fluid. Exchange of manganite oxygen with water occurs without any observable change in mineral phase and appears to be independent of the rapid Mn(II) sorption kinetics. These experiments suggest that Mn(II) catalyzes manganese oxide recrystallization and illustrate a new pathway by which these ubiquitous minerals interact with their surrounding fluid.

  15. A retrospective study on related factors affecting the survival rate of dental implants

    Science.gov (United States)

    Kang, Jeong-Kyung; Lee, Ki; Lee, Yong-Sang; Park, Pil-Kyoo

    2011-01-01

    PURPOSE The aim of this retrospective study is to analyze the relationship between local factors and survival rate of dental implant which had been installed and restored in Seoul Veterans Hospital dental center for past 10 years. And when the relationship is found out, it could be helpful to predict the prognosis of dental implants. MATERIALS AND METHODS A retrospective study of patients receiving root-shaped screw-type dental implants placed from January 2000 to December 2009 was conducted. 6385 implants were placed in 3755 patients. The following data were collected from the dental records and radiographs: patient's age, gender, implant type and surface, length, diameter, location of implant placement, bone quality, prosthesis type. The correlations between these data and survival rate were analyzed. Statistical analysis was performed with the use of Kaplan-Meier analysis, Chi-square test and odds ratio. RESULTS In all, 6385 implants were placed in 3755 patients (3120 male, 635 female; mean age 65 ± 10.58 years). 108 implants failed and the cumulative survival rate was 96.33%. There were significant differences in age, implant type and surface, length, location and prosthesis type (P.05). CONCLUSION Related factors such as age, implant type, length, location and prosthesis type had a significant effect on the implant survival. PMID:22259704

  16. Friction and wear measurements of 50 keV N implanted stainless steels

    Science.gov (United States)

    Ikeyama, Masami; Miyagawa, Soji; Clissold, Ronald A.; Wielunski, Leszek S.; Swain, Michael V.

    1997-05-01

    Features of friction, wear and hardness of 50 keV nitrogen implanted 13Cr type, C and V rich stainless steel was studied. The implantation was carried out at room temperature (300 K) or about 800 K to the doses of 1 × 10 18 and 5 × 10 17 ions/cm 2. Friction coefficient was measured using steel or silicon nitride balls with the loads of 98 to 980 mN. Friction coefficient depended on upper contact ball materials and loads, and changed from an initial value of 0.1 to final values between 0.2 and 0.8. After implantation, the surface became softer due to amorphization, however, it became relatively harder around the projected range of implanted N. 800 K implantation reduced the amorphization and enhanced diffusion of nitrogen. For the silicon nitride ball, implanted surfaces showed a lower friction coefficient than unimplanted region, particularly for 800 K implantation. When the friction coefficient increased, a considerable amount of adhered debris was observed on stainless steel surfaces.

  17. Body surface localization using laser auxiliary X-ray in orthopaedic implant internal fixation%光辅助X射线体表定位在骨科植入物内固定中的应用★

    Institute of Scientific and Technical Information of China (English)

    王明鑫; 熊敏; 刘德昌

    2013-01-01

    BACKGROUND: C-arm X-ray machine is often used in orthopedic surgery to perform the body surface localization. But the repeatedly perspective during the fixation surgery wil increase the damage to the human body and prolong operation time. OBJECTIVE: To explore a kind of simple practical technology of body surface localization by laser auxiliary X-ray used in the orthopedic surgery. METHODS: The radar-shaped red laser was projected in the body surface by self-made simple device to assistant the C-arm machine to perform body surface localization. Sprague Dawley rats and New Zealand white rabbits were used to design animal experiment, three kinds of orthopedic surgeries were simulated. Traditional C-arm machine and the technology of body surface localization by laser auxiliary X-ray was used separately to get position of foreign body in soft tissue, place the distal cross-bolting of fracture intramedul ary nail, and place the pedicle screw in spinal surgery. There were 30 cases in every test. The influence of two methods to the operation was analyzed, and the influence of depth and living body to the technology of body surface localization by laser auxiliary X-ray was analyzed. RESULTS AND CONCLUSION: Compared with the traditional C-arm machine, the technology of body surface localization by laser auxiliary X-ray could obtain the body surface localization more faster (P   目的:探寻一种简便实用、更有利于骨科内固定的光辅助 X 射线体表定位技术。  方法:使用自制的简易装置将雷达状的红色激光投射在体表来辅助 C 臂机进行体表定位。使用 SD 大鼠和新西兰大白兔设计动物实验,模拟软组织内异物定位、骨折髓内钉远端锁钉置入、脊柱椎弓根螺钉进针点定位3种骨科内固定方法。分别使用传统 C 臂机和光辅助 X 射线体表定位技术各进行30次定位。分析2种方法对操作的影响,并分析深度和活体因素对光辅助 X 射线体

  18. CDK4-mediated MnSOD activation and mitochondrial homeostasis in radioadaptive protection

    Science.gov (United States)

    Jin, Cuihong; Qin, Lili; Shi, Yan; Candas, Demet; Fan, Ming; Lu, Chung-Ling; Vaughan, Andrew T. M.; Shen, Rulong; Wu, Larry S.; Liu, Rui; Li, Robert F.; Murley, Jeffrey S.; Gayle, Woloschak; Grdina, David J.; Li, Jian Jian

    2015-01-01

    Mammalian cells are able to sense environmental oxidative and genotoxic conditions such as the environmental low dose ionizing radiation (LDIR) present naturally on earth surface. The stressed cells then can induce a so-called radioadaptive response with an enhanced cellular homeostasis and repair capacity against subsequent similar genotoxic conditions such as a high dose radiation. MnSOD, a primary mitochondrial antioxidant in mammals, has long been known to play a crucial role in the radioadaptive protection through detoxifying O2·- generated by mitochondrial oxidative phosphorylation. Contrasted to the well-studied mechanisms of SOD2 gene regulation, the mechanisms underlying post-translational regulation of MnSOD for radioprotection remain to be defined. Herein, we demonstrate that Cyclin D1-cyclin-dependent kinase 4 (CDK4) serves as the messenger to deliver the stress signal to mitochondria to boost mitochondrial homeostasis in human skin keratinocytes under LDIR adaptive radioprotection. Cyclin D1/CDK4 is found to relocate to mitochondria at the same time as MnSOD enzymatic activation peaks without significant changes of total MnSOD protein level. The mitochondrial-localized CDK4 directly phosphorylates MnSOD at Serine 106 (S106), causing enhanced MnSOD enzymatic activity and mitochondrial respiration. Expression of mitochondria-targeted dominant negative CDK4 or the MnSOD-S106A mutant reverses LDIR-induced mitochondrial enhancement and adaptive protection. The CDK4-mediated MnSOD activation and mitochondrial metabolism boost are also detected in skin tissues of mice receiving in vivo whole body LDIR. These results demonstrate a unique CDK4-mediated mitochondrial communication that allows cells to sense environmental genotoxic stress and boost mitochondrial homeostasis via enhancing phosphorylation and activation of MnSOD. PMID:25578653

  19. Structural characterization of terrestrial microbial Mn oxides from Pinal Creek, AZ

    Energy Technology Data Exchange (ETDEWEB)

    Bargar, John; Fuller, Christopher; Marcus, Matthew A.; Brearley, Adrian J.; Perez De la Rosa, M.; Webb, Samuel M.; Caldwell, Wendel A.

    2008-03-19

    The microbial catalysis of Mn(II) oxidation is believed to be a dominant source of abundant sorption- and redox-active Mn oxides in marine, freshwater, and subsurface aquatic environments. In spite of their importance, environmental oxides of known biogenic origin have generally not been characterized in detail from a structural perspective. Hyporheic zone Mn oxide grain coatings at Pinal Creek, Arizona, a metals-contaminated stream, have been identified as being dominantly microbial in origin and are well studied from bulk chemistry and contaminant hydrology perspectives. This site thus presents an excellent opportunity to study the structures of terrestrial microbial Mn oxides in detail. XRD and EXAFS measurements performed in this study indicate that the hydrated Pinal Creek Mn oxide grain coatings are layer-type Mn oxides with dominantly hexagonal or pseudo-hexagonal layer symmetry. XRD and TEM measurements suggest the oxides to be nanoparticulate plates with average dimensions on the order of 11 nm thick x 35 nm diameter, but with individual particles exhibiting thickness as small as a single layer and sheets as wide as 500 nm. The hydrated oxides exhibit a 10-A basal-plane spacing and turbostratic disorder. EXAFS analyses suggest the oxides contain layer Mn(IV) site vacancy defects, and layer Mn(III) is inferred to be present, as deduced from Jahn-Teller distortion of the local structure. The physical geometry and structural details of the coatings suggest formation within microbial biofilms. The biogenic Mnoxides are stable with respect to transformation into thermodynamically more stable phases over a time scale of at least 5 months. The nanoparticulate layered structural motif, also observed in pure culture laboratory studies, appears to be characteristic of biogenic Mn oxides and may explain the common occurrence of this mineral habit in soils and sediments.

  20. Osseointegration of biochemically modified implants in an osteoporosis rodent model

    Directory of Open Access Journals (Sweden)

    B Stadlinger

    2013-07-01

    Full Text Available The present study examined the impact of implant surface modifications on osseointegration in an osteoporotic rodent model. Sandblasted, acid-etched titanium implants were either used directly (control or were further modified by surface conditioning with NaOH or by coating with one of the following active agents: collagen/chondroitin sulphate, simvastatin, or zoledronic acid. Control and modified implants were inserted into the proximal tibia of aged ovariectomised (OVX osteoporotic rats (n = 32/group. In addition, aged oestrogen competent animals received either control or NaOH conditioned implants. Animals were sacrificed 2 and 4 weeks post-implantation. The excised tibiae were utilised for biomechanical and morphometric readouts (n = 8/group/readout. Biomechanical testing revealed at both time points dramatically reduced osseointegration in the tibia of oestrogen deprived osteoporotic animals compared to intact controls irrespective of NaOH exposure. Consistently, histomorphometric and microCT analyses demonstrated diminished bone-implant contact (BIC, peri-implant bone area (BA, bone volume/tissue volume (BV/TV and bone-mineral density (BMD in OVX animals. Surface coating with collagen/chondroitin sulphate had no detectable impact on osseointegration. Interestingly, statin coating resulted in a transient increase in BIC 2 weeks post-implantation; which, however, did not correspond to improvement of biomechanical readouts. Local exposure to zoledronic acid increased BIC, BA, BV/TV and BMD at 4 weeks. Yet this translated only into a non-significant improvement of biomechanical properties. In conclusion, this study presents a rodent model mimicking severely osteoporotic bone. Contrary to the other bioactive agents, locally released zoledronic acid had a positive impact on osseointegration albeit to a lesser extent than reported in less challenging models.

  1. GaAs-MnAs nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Sadowski, Janusz [MAX-Lab, Lund University, P.O. Box 118, 221 00 Lund (Sweden); Institute of Physics, Polish Academy of Sciences, al. Lotnikow 32/46, 02-668 Warszawa (Poland); Siusys, Aloyzas; Wojciechowski, Tomasz; Reszka, Anna; Kowalski, Bogdan [Institute of Physics, Polish Academy of Sciences, al. Lotnikow 32/46, 02-668 Warszawa (Poland); Kovacs, Andras; Kasama, Takeshi [Center for Electron Nanoscopy, Technical University of Denmark, Kgs. Lyngby 2800 (Denmark); Dunin-Borkowski, Rafal E. [Center for Electron Nanoscopy, Technical University of Denmark, Kgs. Lyngby 2800 (Denmark); Institute for Microstructure Research, Peter Gruenberg Institute, Forschungszentrum Juelich, 52425 Juelich (Germany)

    2011-07-15

    Different strategies for obtaining nanowires (NWs) with ferromagnetic properties using the molecular beam epitaxy (MBE) grown nanostructures combining GaAs and Mn were investigated. Four types of structures have been studied: (i) self-catalyzed GaAs:Mn NWs grown at low temperatures on GaAs(100) substrates; (ii) GaAs:Mn NWs grown at high temperatures on Si(100) substrates; (iii) GaAs-GaMnAs core-shell NW structures; (iv) GaAs-MnAs core-shell NW structures grown on Si(100). Structures of types (i), (iii), and (iv) exhibit ferromagnetic properties. Right: Scanning electron microscopy image of Mn doped GaAs NWs with Ga droplets at the tops, grown by MBE on oxidized Si(100) substrate in the autocatalytic growth mode. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. Peri-Implant Bone Loss and Peri-Implantitis: A Report of Three Cases and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Vanchit John

    2016-01-01

    Full Text Available Dental implant supported restorations have been added substantially to the clinical treatment options presented to patients. However, complications with these treatment options also arise due to improper patient selection and inadequate treatment planning combined with poor follow-up care. The complications related to the presence of inflammation include perimucositis, peri-implant bone loss, and peri-implantitis. Prevalence rates of these complications have been reported to be as high as 56%. Treatment options that have been reported include nonsurgical therapy, the use of locally delivered and systemically delivered antibiotics, and surgical protocols aimed at regenerating the lost bone and soft tissue around the implants. The aim of this article is to report on three cases and review some of the treatment options used in their management.

  3. A feasibility study of magnetic resonance imaging of silicone breast implants in Finland

    DEFF Research Database (Denmark)

    Kulmala, Ilona; Boice, John D; McLaughlin, Joseph K

    2005-01-01

    Cosmetic breast implants have become increasingly popular throughout the world. However, there is insufficient knowledge about the frequency and severity of local complications such as rupture and capsular contracture. A pilot study of 25 Finnish women with 50 cosmetic breast implants was organized...

  4. Dimensions of the healthy gingiva and peri-implant mucosa.

    Science.gov (United States)

    Parpaiola, Andrea; Cecchinato, Denis; Toia, Marco; Bressan, Eriberto; Speroni, Stefano; Lindhe, Jan

    2015-06-01

    To determine the dimensions of the soft tissue cuff present at various aspects of teeth and to compare these dimensions to those of the mucosa surrounding single implants. Fifty volunteers were recruited that were ≥25 years of age and exhibited no signs of (i) untreated caries; (ii) loss of periodontal tissue support in the incisor, canine, and premolar regions; (iii) systemic or local disease. Furthermore, among the 50 patients recruited (iV), 27 had one single implant in the maxilla with teeth present mesial and/or distal to the implant. Probing pocket depth (PPD) and transmucosal sounding depth (TS) were assessed by five experienced, carefully calibrated examiners and with the use of a periodontal probe at the proximal (mesial, distal) and flat (facial, buccal and palatal/lingual) surfaces of all teeth/implants. The width of the keratinized mucosa (KM) was also determined. It was demonstrated that (i) PPD and TS were greater at proximal than at flat surfaces at both tooth and implant sites. In addition, both PPD and TS were deeper at implant than at tooth sites. The TS values documented that the cuff of healthy soft tissue that surrounded a tooth varied between 2 mm at flat surfaces and 4 mm at proximal surfaces, while at implant sites, the mucosa at proximal as well as flat surfaces was 1-1.5 mm greater. The probing pocket depth (PPD) and the transmucosal sounding depth (TS) values were greater at proximal than at flat, that is, facial/palatal (lingual) surfaces at tooth sites and frequently also at implant sites. Furthermore, the PPD and the TS dimensions were greater at implant than at adjacent tooth sites. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Development of vertical compact ion implanter for gemstones applications

    Energy Technology Data Exchange (ETDEWEB)

    Intarasiri, S., E-mail: saweat@gmail.com [Science and Technology Research Institute, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand); Wijaikhum, A. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Bootkul, D., E-mail: mo_duangkhae@hotmail.com [Department of General Science (Gems and Jewelry), Faculty of Science, Srinakharinwirot University, Bangkok 10110 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand); Suwannakachorn, D.; Tippawan, U.; Yu, L.D.; Singkarat, S. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2014-08-15

    Ion implantation technique was applied as an effective non-toxic treatment of the local Thai natural corundum including sapphires and rubies for the enhancement of essential qualities of the gemstones. Energetic oxygen and nitrogen ions in keV range of various fluences were implanted into the precious stones. It has been thoroughly proved that ion implantation can definitely modify the gems to desirable colors together with changing their color distribution, transparency and luster properties. These modifications lead to the improvement in quality of the natural corundum and thus its market value. Possible mechanisms of these modifications have been proposed. The main causes could be the changes in oxidation states of impurities of transition metals, induction of charge transfer from one metal cation to another and the production of color centers. For these purposes, an ion implanter of the kind that is traditionally used in semiconductor wafer fabrication had already been successfully applied for the ion beam bombardment of natural corundum. However, it is not practical for implanting the irregular shape and size of gem samples, and too costly to be economically accepted by the gem and jewelry industry. Accordingly, a specialized ion implanter has been requested by the gem traders. We have succeeded in developing a prototype high-current vertical compact ion implanter only 1.36 m long, from ion source to irradiation chamber, for these purposes. It has been proved to be very effective for corundum, for example, color improvement of blue sapphire, induction of violet sapphire from low value pink sapphire, and amelioration of lead-glass-filled rubies. Details of the implanter and recent implantation results are presented.

  6. Development of vertical compact ion implanter for gemstones applications

    Science.gov (United States)

    Intarasiri, S.; Wijaikhum, A.; Bootkul, D.; Suwannakachorn, D.; Tippawan, U.; Yu, L. D.; Singkarat, S.

    2014-08-01

    Ion implantation technique was applied as an effective non-toxic treatment of the local Thai natural corundum including sapphires and rubies for the enhancement of essential qualities of the gemstones. Energetic oxygen and nitrogen ions in keV range of various fluences were implanted into the precious stones. It has been thoroughly proved that ion implantation can definitely modify the gems to desirable colors together with changing their color distribution, transparency and luster properties. These modifications lead to the improvement in quality of the natural corundum and thus its market value. Possible mechanisms of these modifications have been proposed. The main causes could be the changes in oxidation states of impurities of transition metals, induction of charge transfer from one metal cation to another and the production of color centers. For these purposes, an ion implanter of the kind that is traditionally used in semiconductor wafer fabrication had already been successfully applied for the ion beam bombardment of natural corundum. However, it is not practical for implanting the irregular shape and size of gem samples, and too costly to be economically accepted by the gem and jewelry industry. Accordingly, a specialized ion implanter has been requested by the gem traders. We have succeeded in developing a prototype high-current vertical compact ion implanter only 1.36 m long, from ion source to irradiation chamber, for these purposes. It has been proved to be very effective for corundum, for example, color improvement of blue sapphire, induction of violet sapphire from low value pink sapphire, and amelioration of lead-glass-filled rubies. Details of the implanter and recent implantation results are presented.

  7. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  8. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    2007-01-01

      Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  9. Opaque intraocular lens implantation

    OpenAIRE

    Yusuf IH; Patel CK

    2013-01-01

    Imran H Yusuf, CK Patel The Oxford Eye Hospital, West Wing, John Radcliffe Hospital, Headley Way, Headington, Oxford, United KingdomWe read with great interest the recent article by Lee et al,1 who described their clinical experience with three patients who underwent primary implantation of Morcher (Stuttgart, Germany) occlusive intraocular lenses (IOLs) across a variety of neuro-ophthalmic indications. We hope to offer some further insight into these clinical observations in the context of o...

  10. Thermodynamic Properties of Mn-C Melts

    Institute of Scientific and Technical Information of China (English)

    CHEN Er-bao; WANG Shi-jun

    2008-01-01

    Carbon solubility in Mn-Fe melts (xMn=0.161-0.706, xFe=0.034-0.633) was measured experimentally at various temperatures. By thermodynamic derivation and calculation, the relationship between activity coefficient of carbon in infinite dilute solution of manganese in Mn-C system and temperature was obtained. Using Gibbs-Duhem relationship, the experimental results of this study, and experimental data reported in references, the relationship between other thermodynamic properties in Mn-C system and temperature were obtained by thermodynamic derivation and calculation.

  11. A method for making Mn02 electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, M.; Nisino, A.

    1983-03-30

    A layer of Mn02, produced during thermal breakdown of manganese salts, is applied to a metallic current outlead. Then a mixture of granulated Mn02 and an electricity conducting additive and a binder is applied to this layer. The electrode contains 1 to 5 percent by mass epoxide resin, 5 to 15 percent by mass carbon powder, 0.1 to 10 percent by mass beta-Mn02 and 70 to 90 percent by mass gamma-Mn02. The electrode has high mechanical strength and good discharge characteristics.

  12. X-ray absorption spectroscopy of Mn doped ZnO thin films prepared by rf sputtering technique

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, Ashok Kumar; Jha, S. N.; Bhattacharyya, D., E-mail: dibyendu@barc.gov.in [Atomic & Molecular Physics Division, Bhabha Atomic Research Centre, Mumbai – 400 085 (India); Haque, Sk Maidul [Atomic & Molecular Physics Division, Bhabha Atomic Research Centre, VIZAG Centre, Visakhapatnam-530012 (India); Shukla, Dinesh; Choudhary, Ram Janay [UGC DAE Consortium for Scientific Research, Indore-452001 (India)

    2015-11-15

    A set of r.f. sputter deposited ZnO thin films prepared with different Mn doping concentrations have been characterised by Extended X-ray Absorption Fine Structure (EXAFS) and X-ray Absorption Near Edge Spectroscopy (XANES) measurements at Zn, Mn and O K edges and at Mn L{sub 2,3} edges apart from long range structural characterisation by Grazing Incident X-ray Diffraction (GIXRD) technique. Magnetic measurements show room temperature ferromagnetism in samples with lower Mn doping which is however, gets destroyed at higher Mn doping concentration. The results of the magnetic measurements have been explained using the local structure information obtained from EXAFS and XANES measurements.

  13. Studies on Electronic Structure and Magnetic Properties of an Organic Magnet with Metallic Mn2+ and Cu2+ Ions

    Institute of Scientific and Technical Information of China (English)

    YAO Jian-Guo; PENG Guang-Xiong

    2004-01-01

    The electronic structure and the magnetic properties of the non-pure organic ferromagnetic compound MnCu(pbaOH)(H2O)3 with pbaOH = 2-hydroxy-1, 3-propylenebis (oxamato) are studied by using the density-functional theory with local-spin-density approximation. The density of states, total energy, and the spin magnetic moment are calculated. The calculations reveal that the compound MnCu(pbaOH)(H20)3 has a stable metal-ferromagnetic ground state, and the spin magnetic moment per molecule is 2.208 μB, and the spin magnetic moment is mainly from Mn ion and Cu ion. An antiferromagnetic order is expected and the antiferromagnetic exchange interaction of d-electrons of Cu and Mn passes through the antiferromagnetic interaction between the adjacent C, O, and N atoms along the path linking the atoms Cu and Mn.

  14. Synthesis and Characterization of Multifunctional Chitosan- MnFe2O4 Nanoparticles for Magnetic Hyperthermia and Drug Delivery

    Directory of Open Access Journals (Sweden)

    David E. Nikles

    2010-07-01

    Full Text Available Multifunctional nanoparticles composed of MnFe2O4 were encapsulated in chitosan for investigation of system to combine magnetically-triggered drug delivery and localized hyperthermia for cancer treatment with the previously published capacity of MnFe2O4 to be used as an efficient MRI contrast agent for cancer diagnosis. This paper focuses on the synthesis and characterization of magnetic MnFe2O4 nanoparticles, their dispersion in water and their incorporation in chitosan, which serves as a drug carrier. The surface of the MnFe2O4 nanoparticles was modified with meso-2,3-di-mercaptosuccinic acid (DMSA to develop stable aqueous dispersions. The nanoparticles were coated with chitosan, and the magnetic properties, heat generation and hydrodynamic size of chitosan-coated MnFe2O4 were evaluated for various linker concentrations and in a range of pH conditions.

  15. Bone Substitutes for Peri-Implant Defects of Postextraction Implants

    Directory of Open Access Journals (Sweden)

    Pâmela Letícia Santos

    2013-01-01

    Full Text Available Placement of implants in fresh sockets is an alternative to try to reduce physiological resorption of alveolar ridge after tooth extraction. This surgery can be used to preserve the bone architecture and also accelerate the restorative procedure. However, the diastasis observed between bone and implant may influence osseointegration. So, autogenous bone graft and/or biomaterials have been used to fill this gap. Considering the importance of bone repair for treatment with implants placed immediately after tooth extraction, this study aimed to present a literature review about biomaterials surrounding immediate dental implants. The search included 56 articles published from 1969 to 2012. The results were based on data analysis and discussion. It was observed that implant fixation immediately after extraction is a reliable alternative to reduce the treatment length of prosthetic restoration. In general, the biomaterial should be used to increase bone/implant contact and enhance osseointegration.

  16. Zirconia in fixed implant prosthodontics.

    Science.gov (United States)

    Guess, Petra Christine; Att, Wael; Strub, Joerg Rudolf

    2012-10-01

    CAD/CAM technology in combination with zirconia ceramic has increasingly gained popularity in implant dentistry. This narrative review presents the current knowledge on zirconia utilized as framework material for implant-borne restorations and implant abutments, laboratory tests and developments, clinical performance, and possible future trends for implant dentistry are addressed. A review of available literature from 1990 through 2010 was conducted with search terms zirconia,"implants,"abutment,"crown," and "fixed dental prosthesis" using electronic databases (PubMed) and manual searching. Latest applications of zirconia in implant dentistry include implant abutments, multiple unit and full-arch frameworks as well as custom-made bars to support fixed and removable prostheses. High biocompatibility, low bacterial surface adhesion as well as favorable chemical properties of zirconia ceramics are reported. Zirconia stabilized with yttrium oxide exhibits high flexural strength and fracture toughness due to a transformation toughening mechanism. Preliminary clinical data confirmed the high stability of zirconia for abutments and as a framework material for implant borne crowns and fixed dental prostheses. Zirconia abutment or framework damage has rarely been encountered. However, veneering porcelain fractures are the most common technical complication in implant-supported zirconia restorations. These porcelain veneer failures have led to concerns regarding differences in coefficient of thermal expansions between core and veneering porcelain and their respective processing techniques. As presently evidence of clinical long-term data is missing, caution with regard to especially extensive implant-borne zirconia frameworks is recommended. © 2010 Wiley Periodicals, Inc.

  17. [Neurotology and cochlear implants].

    Science.gov (United States)

    Merchán, Miguel A

    2015-05-01

    In this review we analyse cochlear implantation in terms of the fundamental aspects of the functioning of the auditory system. Concepts concerning neuronal plasticity applied to electrical stimulation in perinatal and adult deep hypoacusis are reviewed, and the latest scientific bases that justify early implantation following screening for congenital deafness are discussed. Finally, this review aims to serve as an example of the importance of fostering the sub-specialty of neurotology in our milieu, with the aim of bridging some of the gaps between specialties and thus improving both the knowledge in the field of research on auditory pathologies and in the screening of patients. The objectives of this review, targeted above all towards specialists in the field of otorhinolaryngology, are to analyse some significant neurological foundations in order to reach a better understanding of the clinical events that condition the indications and the rehabilitation of patients with cochlear implants, as well as to use this means to foster the growth of the sub-specialty of neurotology.

  18. An evidence of trap activation for positive temperature coefficient of resistivity in BaTiO3 ceramics with substitutional Nb and Mn as impurities

    Science.gov (United States)

    Miki, Toshikatsu; Fujimoto, Akira; Jida, Shin'suke

    1998-02-01

    The mechanism of the electrical resistivity increase above the Curie temperature TC [so-called positive temperature coefficient of resistivity (PTCR) effect] in BaTi1-x-yNbxMnyO3 ceramics is studied with the temperature-dependent resistivity and electron paramagnetic resonance (EPR) data and the calculated energy levels of various Mn-associated centers. The activation energy of trapped electrons at grain boundary interface states is deduced from the resistivity data. The deduced value is found to be nearly equal to the activation energy of Mn2+ and/or singlet EPR signals. This indicates that the EPR signals arising at the cubic phase are due to trapped-electron centers at grain boundaries, and that the centers responsible for the EPR signals contribute to the rise of grain boundary barrier above TC. The PTCR mechanism is separately discussed for mode I of abrupt resistivity jump at TC and mode II of moderate resistivity increase at higher temperatures. From the analyses of resistivity and EPR data, we found that mode II PTCR is well explained by the Heywang model, but mode I PTCR is hardly explained only by the effect of spontaneous polarization proposed by Jonker. Defect models of Mn-VO, Mn-VO-Mn, and Mn-O-Nb-VO type are proposed for Mn associated centers and VBa-VO or VO-VTi-VO type for cation-vacancy-associated centers, taking the local electroneutrality requirement for stable defects and the electronic energy change of substitutional Mn by phase transitions into account. Changes of the electronic energy levels of such defects by phase transitions successfully explain not only the PTCR and EPR data but also the degraded PTCR by incomplete or overabundant oxidation. A part of the Mn-VO centers formed at low Mn contents release electrons at the tetragonal phase forming Mn3+-VO with an effective charge of +1 to act as a charge compensator for negatively charged acceptors at the grain boundary, but the Mn-VO centers hardly act as acceptor-type electron

  19. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  20. The use of phentolamine mesylate to evaluate mandibular nerve damage following implant placement.

    Science.gov (United States)

    Froum, Stuart J; Froum, Scott H; Malamed, Stanley F

    2010-09-01

    High success rates and long-term predictability of implant therapy have been well documented in the literature. However, complications in implant treatment can arise and include sensory disturbances, especially in the posterior mandible in areas close to the inferior alveolar nerve. Treatment efficacy of sensory disturbances caused by implant placement in this area relies on the expeditious diagnosis of an induced paresthesia. Recently, phentolamine mesylate has been introduced as a reversal agent of local anesthesia with the ability to decrease the requisite time for a patient to return to normal sensation. This article introduces a method for faster detection of a potential paresthesia induced by implant placement in the posterior mandible.

  1. Direct observation of the lattice sites of implanted manganese in silicon

    CERN Document Server

    Silva, Daniel; Wahl, Ulrich; Martins Correia, Joao; Amorim, Lígia; Decoster, Stefan; Castro Ribeiro Da Silva, Manuel; Da Costa Pereira, Lino Miguel; Esteves De Araujo, Araujo Joao Pedro

    2016-01-01

    Mn-doped Si has attracted significant interest in the context of dilute magnetic semiconductors. We investigated the lattice location of implanted Mn in silicon of different doping types (n, n+ and p+) in the highly dilute regime. Three different lattice sites were identified by means of emission channeling experiments: ideal substitutional sites; sites displaced from bond-centered towards substitutional sites and sites displaced from anti-bonding towards tetrahedral interstitial sites. For all doping types investigated, the substitutional fraction remained below ∼ 30%. We discuss the origin of the observed lattice sites as well as the implications of such structures on the understanding of Mn-doped Si systems.

  2. Biocorrosion investigation of two shape memory nickel based alloys: Ni-Mn-Ga and thin film NiTi.

    Science.gov (United States)

    Stepan, L L; Levi, D S; Gans, E; Mohanchandra, K P; Ujihara, M; Carman, G P

    2007-09-01

    Thin film nitinol and single crystal Ni-Mn-Ga represent two new shape memory materials with potential to be used as percutaneously placed implant devices. However, the biocompatibility of these materials has not been adequately assessed. Immersion tests were conducted on both thin film nitinol and single crystal Ni-Mn-Ga in Hank's balanced salt solution at 37 degrees C and pH 7.4. After 12 h, large pits were found on the Ni-Mn-Ga samples while thin film nitinol displayed no signs of corrosion. Further electrochemical tests on thin film nitinol samples revealed breakdown potentials superior to a mechanically polished nitinol disc. These results suggest that passivation or electropolishing of thin film nitinol maybe unnecessary to promote corrosion resistance.

  3. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability.

  4. Tissue response to the components of a hydroxyapatite-coated composite femoral implant.

    Science.gov (United States)

    Hacking, S A; Pauyo, T; Lim, L; Legoux, J G; Bureau, M N

    2010-09-01

    Bone loss around femoral implants used for THA is a persistent clinical concern. It may be caused by stress shielding, generally attributed to a mismatch in stiffness between the implants and host bone. In this regard, a fatigue resistant, carbon fiber (CF) composite femoral implant with bone-matching stiffness has been developed. This study evaluated the tissue response to the three material components of this implant in normal and textured (blasted with 24 grit alumina) surfaces: the hydroxyapatite (HA) coating, the CF composite and the intermediate crystalline HA particulate composite layer to bond to the HA coating (blended). Sprague-Dawley rats underwent bilateral femoral implantation each receiving two rod-like implants. Bone apposition to the HA (37%) and textured Ti (41%) implants was not significantly different. Bone apposition to the untextured CF (14%) and blended (19%) implants and polished Ti (8%) implants was significantly lower. Bone apposition to the textured CF (9%) and blended (11%) implants was lower (but not statistically from the as received or untextured counterparts). Nearly all sections from femurs containing CF implants presented CF debris. There was no evidence of localized bone loss or any strong immune response associated with any of the implant materials. All materials were well tolerated with minimal inflammation despite the presence of particulate debris. The high degree of bone apposition to the HA-coated composite implants and the lack of short-term inflammation and adverse tissue response to the three material implant component support continued evaluation of this composite technology for use in THA.

  5. MnO2-protected silver nanoparticles: New electromagnetic nanoresonators for Raman analysis of surfaces in basis environment

    Science.gov (United States)

    Abdulrahman, Heman Burhanalden; Kołątaj, Karol; Lenczewski, Paweł; Krajczewski, Jan; Kudelski, Andrzej

    2016-12-01

    The first example of the synthesis of Ag nanoparticles protected by a few nanometers thick layer of MnO2 (Ag@MnO2) has been reported. Synthesized Ag@MnO2 nanoparticles effectively locally enhance the electric field of the incident visible radiation, which allows, for example, for a large enhancement of the efficiency of Raman scattering for species located in the close proximity to such nanostructures. It means that Ag@MnO2 nanoparticles may be used as nanoresonators for shell-isolated nanoparticle-enhanced Raman scattering (SHINERS) measurements. The obtained Ag@MnO2 nanoparticles are almost two orders of magnitude more efficient in enhancing Raman signal than previously used for SHINERS measurements in the alkali environment Au@MnO2 nanostructures. Moreover, in comparison to Ag@SiO2 nanoparticles, which are standard silver nanoresonators for SHINERS experiments, Ag@MnO2 nanoparticles are significantly more stable in the basic conditions. Deposition of the MnO2 layer (by the reduction of KMnO4 with by K2C2O4 in an alkaline condition) on hollow silver nanoparticles (h-Ag) has been also analyzed. Hollow silver shells are significantly less stable than the solid Ag nanostructures and are practically entirely destroyed during the process of the MnO2 deposition. However, in this condition, the majority of h-Ag nanoparticles form agglomerates containing about 101 h-Ag items which are connected by MnO2, and after dissolution of the silver auxiliary templates very regular MnO2 sponge nanostructures with the diameter of 150-300 nm are formed.

  6. Evolution of novel bioresorbable iron-manganese implant surfaces and their degradation behaviors in vitro.

    Science.gov (United States)

    Heiden, Michael; Walker, Emily; Nauman, Eric; Stanciu, Lia

    2015-01-01

    The purpose of this study is to advance understanding of surface degradation kinetics for Fe-Mn bioresorbable alloys (specifically Fe-20%Mn) and target degradable fracture fixation implants for hard tissues. This study addresses how arc melted Fe-20%Mn discs degrade in a static, osteogenic medium for up to a 3 month time span. Degradation behavior of these bulk alloys was investigated using both mass loss tests for measuring long-term corrosion rates and potentiostatic tests for following the instantaneous rate of degradation. It was discovered that cold-rolling Fe-20%Mn to 77% cold work (CW) suppressed the instantaneous corrosion rate compared with the cast structure. It was also found that an unstable iron-rich oxide layer forms on the entire surface of these bulk samples and the act of machining the bulk metal into a defined shape may affect the morphology of the oxide layer on the outer edge of the samples during degradation. The mechanisms behind the surface evolution of these potential orthopedic implants are investigated in detail.

  7. Mixed Zn and O substitution of Co and Mn in ZnO

    CERN Document Server

    Pereira, Lino Miguel da Costa; Decoster, Stefan; Correia, João Guilherme; Amorim, Lígia Marina; da Silva, Manuel Ribeiro; Araújo, João Pedro; Vantomme, André

    2011-01-01

    The physical properties of an impurity atom in a semiconductor are primarily determined by the lattice site it occupies. In general, this occupancy can be correctly predicted based on chemical intuition, but not always. We report on one such exception in the dilute magnetic semiconductors Co- and Mn-doped ZnO, experimentally determining the lattice location of Co and Mn using $\\beta$-emission channeling from the decay of radioactive $^{61}$Co and $^{56}$Mn implanted at the ISOLDE facility at CERN. Surprisingly, in addition to the majority substituting for Zn, we find up to 18% (27%) of the Co (Mn) atoms in O sites, which is virtually unaffected by thermal annealing up to 900 °C. We discuss how this anion site configuration, which had never been considered before for any transition metal in any metal oxide material, may in fact have a low formation energy. This suggests a change in paradigm regarding transition-metal incorporation in ZnO and possibly other oxides and wide-gap semiconductors.

  8. Microstructural, mechanical, corrosion and cytotoxicity characterization of the hot forged FeMn30(wt.%) alloy.

    Science.gov (United States)

    Čapek, Jaroslav; Kubásek, Jiří; Vojtěch, Dalibor; Jablonská, Eva; Lipov, Jan; Ruml, Tomáš

    2016-01-01

    An interest in biodegradable metallic materials has been increasing in the last two decades. Besides magnesium based materials, iron-manganese alloys have been considered as possible candidates for fabrication of biodegradable stents and orthopedic implants. In this study, we prepared a hot forged FeMn30 (wt.%) alloy and investigated its microstructural, mechanical and corrosion characteristics as well as cytotoxicity towards mouse L 929 fibroblasts. The obtained results were compared with those of iron. The FeMn30 alloy was composed of antiferromagnetic γ-austenite and ε-martensite phases and possessed better mechanical properties than iron and even that of 316 L steel. The potentiodynamic measurements in simulated body fluids showed that alloying with manganese lowered the free corrosion potential and enhanced the corrosion rate, compared to iron. On the other hand, the corrosion rate of FeMn30 obtained by a semi-static immersion test was significantly lower than that of iron, most likely due to a higher degree of alkalization in sample surrounding. The presence of manganese in the alloy slightly enhanced toxicity towards the L 929 cells; however, the toxicity did not exceed the allowed limit and FeMn30 alloy fulfilled the requirements of the ISO 10993-5 standard.

  9. Current trends in dental implants

    OpenAIRE

    Gaviria, Laura; Salcido, John Paul; Guda, Teja; Ong, Joo L.

    2014-01-01

    Tooth loss is very a very common problem; therefore, the use of dental implants is also a common practice. Although research on dental implant designs, materials and techniques has increased in the past few years and is expected to expand in the future, there is still a lot of work involved in the use of better biomaterials, implant design, surface modification and functionalization of surfaces to improve the long-term outcomes of the treatment. This paper provides a brief history and evoluti...

  10. Dental Implants: Dual Stabilization Technology

    OpenAIRE

    Saini, Rajiv

    2015-01-01

    More recent epidemiological data seem to show an increasing trend of tooth loss due to periodontal reasons rather than caries; the presence of initial attachment loss, bone height and the habit of smoking significantly increase the risk of tooth mortality. A dental implant is a titanium screw which is placed into bone to replace missing teeth. The implant mimics the root of a tooth in function. Dental Implants have changed the face of dentistry over the last three decades. Success of dental i...

  11. Thermal diffusion of Mn through GaAs overlayers on (Ga, Mn)As

    Energy Technology Data Exchange (ETDEWEB)

    Adell, J; Ulfat, I; Ilver, L; Kanski, J [Department of Applied Physics, Chalmers University of Technology, SE-412 96 Gothenburg (Sweden); Sadowski, J [Institute of Physics, Polish Academy of Sciences, PL-02-668 Warsaw (Poland); Karlsson, K [Department of Life Sciences, University of Skoevde, SE-541 28 Skoevde (Sweden)

    2011-03-02

    Thermally stimulated diffusion of Mn through thin layers of GaAs has been studied by x-ray photoemission. (Ga, Mn)As samples with 5 at% Mn were capped with 4, 6 and 8 monolayer (ML) GaAs, and Mn diffusing through the GaAs was trapped on the surface by means of amorphous As. It was found that the out-diffusion is completely suppressed for an 8 ML thick GaAs film. The short diffusion length is attributed to an electrostatic barrier formed at the (Ga, Mn)As/GaAs interface.

  12. Thermal diffusion of Mn through GaAs overlayers on (Ga, Mn)As.

    Science.gov (United States)

    Adell, J; Ulfat, I; Ilver, L; Sadowski, J; Karlsson, K; Kanski, J

    2011-03-02

    Thermally stimulated diffusion of Mn through thin layers of GaAs has been studied by x-ray photoemission. (Ga, Mn)As samples with 5 at% Mn were capped with 4, 6 and 8 monolayer (ML) GaAs, and Mn diffusing through the GaAs was trapped on the surface by means of amorphous As. It was found that the out-diffusion is completely suppressed for an 8 ML thick GaAs film. The short diffusion length is attributed to an electrostatic barrier formed at the (Ga, Mn)As/GaAs interface.

  13. Mechanical alloying of Fe-Mn and Fe-Mn-Si

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    The ball milling of Fe-24Mn and Fe-24Mn-6Si mixed powders has been performed by the high energy ball milling technique.By employing X-ray diffraction and Moessbauer measurements.The ccmposition evolution during the milling process has been investigated.The results indicate the formation of paramagnetic Fe-Mn or Fe-Mn-Si alloys with a metastable fcc phase as final products.which imply that the Fe and Mn proceed a co-diffusion meenanism through the surface of fragmented powders.The thermal stability and composition evolution of the as-milled alloys were discussed comparing with the bulk alloy,.

  14. Spectral luminescent properties of bacteriochlorin and aluminum phthalocyanine nanoparticles as hydroxyapatite implant surface coating

    Directory of Open Access Journals (Sweden)

    Yu. S. Maklygina

    2016-01-01

    Full Text Available The development and the spectral research of unique coating as crystalline nanoparticles of IR photosensitizers were performed for the creation of hydroxyapatite implants with photobactericidal properties. It has been proved that by the interaction of nanoparticles covering implant with the polar solvent, which simulates the interaction of the implant with the biocomponents in vivo (fast proliferating and with immunocompetent cells, photosensitizers nanoparticles change the spectroscopic properties, becoming fluorescent and phototoxic. Thus, the developed coating based on crystalline photosensitizer nanoparticles with studied specific properties should have antibacterial, anti-inflammatory effect by the photodynamic treatment in the near implant area. This research opens the prospect of the local prevention of inflammatory and autoimmune reactions in the area of implantation. The results of the study suggest a promising this technology in order to create implants with photobactericidal properties.

  15. Nanobiotechnology Perspectives on Prevention and Treatment of Ortho-paedic Implant Associated Infection.

    Science.gov (United States)

    Borse, Vivek; Pawar, Vaishali; Shetty, Gautam; Mullaji, Arun; Srivastava, Rohit

    2016-01-01

    Implants are an inevitable part of orthopaedic surgery. However, implant associated infection remains a major challenge for orthopaedic surgeons and researchers. This review focuses on current options available for prevention of implant associated infection, their drawbacks and future promising applications of nanotechnology-based approaches. Nanobiotechnology has shown remarkable progress in recent years especially in biomaterials, diagnostics, and drug delivery system. Although several applications of nanobiotechnology in orthopaedics have been described, few have elaborated their role in the prevention of implant related infection in orthopaedics. Novel "smart" drug delivery systems that release antibiotics locally in response to stimuli such as pH, temperature, enzymes or antigens; implant surface modification on a nanoscale to inhibit bacterial adhesion and propagation at the surgical site and biological approaches such as gene therapy to neutralize bacterial virulence and biomolecules to inhibit the quorum sensing adhesion of bacteria and disruption of biofilms can be used effectively to prevent orthopaedic implant related bacterial infection.

  16. Influence of cochleostomy and cochlear implant insertion on drug gradients following intratympanic application in guinea pigs

    Science.gov (United States)

    King, EB; Hartsock, JJ; O'Leary, SJ; Salt, AN

    2013-01-01

    Locally-applied drugs can protect residual hearing following cochlear implantation. The influence of cochlear implantation on drug levels in scala tympani (ST) after round window application was investigated in guinea pigs using the marker trimethylphenlyammonium (TMPA) measured in real-time with TMPA-selective microelectrodes. TMPA concentration in the upper basal turn of ST rapidly increased during implantation and then declined due to cerebrospinal fluid entering ST at the cochlear aqueduct and exiting at the cochleostomy. The TMPA increase was found to be caused by the cochleostomy drilling, if the burr tip partially entered ST. TMPA distribution in the second turn was less affected by implantation procedures. These findings show that basal turn drug levels may be changed during implantation and the changes may need to be considered in the interpretation of therapeutic effects of drugs in conjunction with implantation. PMID:24008355

  17. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  18. Mn(II) Oxidation by the Multicopper Oxidase Complex Mnx: A Coordinated Two-Stage Mn(II)/(III) and Mn(III)/(IV) Mechanism.

    Science.gov (United States)

    Soldatova, Alexandra V; Romano, Christine A; Tao, Lizhi; Stich, Troy A; Casey, William H; Britt, R David; Tebo, Bradley M; Spiro, Thomas G

    2017-08-23

    The bacterial manganese oxidase MnxG of the Mnx protein complex is unique among multicopper oxidases (MCOs) in carrying out a two-electron metal oxidation, converting Mn(II) to MnO2 nanoparticles. The reaction occurs in two stages: Mn(II) → Mn(III) and Mn(III) → MnO2. In a companion study , we show that the electron transfer from Mn(II) to the low-potential type 1 Cu of MnxG requires an activation step, likely forming a hydroxide bridge at a dinuclear Mn(II) site. Here we study the second oxidation step, using pyrophosphate (PP) as a Mn(III) trap. PP chelates Mn(III) produced by the enzyme and subsequently allows it to become a substrate for the second stage of the reaction. EPR spectroscopy confirms the presence of Mn(III) bound to the enzyme. The Mn(III) oxidation step does not involve direct electron transfer to the enzyme from Mn(III), which is shown by kinetic measurements to be excluded from the Mn(II) binding site. Instead, Mn(III) is proposed to disproportionate at an adjacent polynuclear site, thereby allowing indirect oxidation to Mn(IV) and recycling of Mn(II). PP plays a multifaceted role, slowing the reaction by complexing both Mn(II) and Mn(III) in solution, and also inhibiting catalysis, likely through binding at or near the active site. An overall mechanism for Mnx-catalyzed MnO2 production from Mn(II) is presented.

  19. Cochlear implants in genetic deafness

    Institute of Scientific and Technical Information of China (English)

    Xuezhong Liu

    2014-01-01

    Genetic defects are one of the most important etiologies of severe to profound sensorineural hearing loss and play an important role in determining cochlear implantation outcomes. While the pathogenic mutation types of a number of deafness genes have been cloned, the pathogenesis mechanisms and their relationship to the outcomes of cochlear implantation remain a hot research area. The auditory performance is considered to be affected by the etiology of hearing loss and the number of surviving spiral ganglion cells, as well as others. Current research advances in cochlear implantation for hereditary deafness, especially the relationship among clinic-types, genotypes and outcomes of cochlear implantation, will be discussed in this review.

  20. Dental implants in growing children

    Directory of Open Access Journals (Sweden)

    S K Mishra

    2013-01-01

    Full Text Available The replacement of teeth by implants is usually restricted to patients with completed craniofacial growth. The aim of this literature review is to discuss the use of dental implants in normal growing patients and in patients with ectodermal dysplasia and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended that while deciding the optimal individual time point of implant insertion, the status of skeletal growth, the degree of hypodontia, and extension of related psychological stress should be taken into account, in addition to the status of existing dentition and dental compliance of a pediatric patient.

  1. Antibiotics in the treatment of peri-implantitis

    NARCIS (Netherlands)

    van Winkelhoff, Arie Jan

    2012-01-01

    Purpose: To review and discuss current literature on the use of systemically administered or locally delivered antibiotics in the treatment of peri-implantitis. Materials and methods: A literature search was conducted using MEDLINE through the Pub Med database of the US National Library of Medicine

  2. Antibiotics in the treatment of peri-implantitis

    NARCIS (Netherlands)

    van Winkelhoff, Arie Jan

    2012-01-01

    Purpose: To review and discuss current literature on the use of systemically administered or locally delivered antibiotics in the treatment of peri-implantitis. Materials and methods: A literature search was conducted using MEDLINE through the Pub Med database of the US National Library of Medicine

  3. Valence state of Mn in Ca-doped LaMnO3 studied by high-resolution Mn K ß emission spectroscopy

    NARCIS (Netherlands)

    Tyson, T.A.; Qian, Q.; Kao, C.-C.; Rueff, J.-P.; Groot, F.M.F. de; Croft, M.; Cheong, S.-W.; Greenblatt, M.; Subramanian, M.A.

    1999-01-01

    Mn K ß x-ray emission spectra provide a direct method to probe the effective spin state and charge density on the Mn atom and is used in an experimental study of a class of Mn oxides. Specifically, the Mn K ß line positions and detailed spectral shapes depend on the oxidation and the spin state of

  4. Valence state of Mn in Ca-doped LaMnO3 studied by high-resolution Mn K ß emission spectroscopy

    NARCIS (Netherlands)

    Tyson, T.A.; Qian, Q.; Kao, C.-C.; Rueff, J.-P.; Groot, F.M.F. de; Croft, M.; Cheong, S.-W.; Greenblatt, M.; Subramanian, M.A.

    2001-01-01

    Mn K ß x-ray emission spectra provide a direct method to probe the effective spin state and charge density on the Mn atom and is used in an experimental study of a class of Mn oxides. Specifically, the Mn K ß line positions and detailed spectral shapes depend on the oxidation and the spin state of t

  5. Phase gap in pseudoternary R1-yRy'Mn2X2-xXx' compounds

    Science.gov (United States)

    Wang, J. L.; Kennedy, S. J.; Campbell, S. J.; Hofmann, M.; Dou, S. X.

    2013-03-01

    Our neutron diffraction investigation of PrMn2Ge2-xSix reveals a clear separation into two magnetic phases, canted ferromagnetic (Fmc) and antiferromagnetic (AFmc), between x = 1.0 and 1.2 and a commensurate phase gap in the lattice, due to magnetostrictive distortion. This remarkable magnetoelastic phenomenon is driven by a nonuniform atomic distribution on the X site which in turn produces subtle variations in the local lattice and abrupt changes in the Mn-Mn magnetic exchange interaction. Our results show that coexistence of Fmc and AFmc phases depends on lattice parameter, chemical pressure from the rare-earth and metalloid sites, and local lattice strain distributions. We demonstrate that these magnetostructural correlations act across the entire family of R1-yRy'Mn2X2-xXx' compounds.

  6. Hexagonal LuMnO3 revisited

    NARCIS (Netherlands)

    Aken, Bas B. van; Meetsma, Auke; Palstra, Thomas T.M.

    2001-01-01

    The crystal structure of hexagonal LuMnO3 at room temperature is isomorphous with YMnO3 and deviates in important details from early work. Mn is near the centre of its oxygen coordination environment. On the threefold axes, the apical O-Lu bonds have alternating long and short bond lengths, leading

  7. Exchange-induced Tm magnetism in multiferroic h-TmMnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Salama, Hazar A; Stewart, G A [School of Physical, Environmental and Mathematical Sciences, University of New South Wales, Australian Defence Force Academy, Canberra 2600 (Australia)

    2009-09-23

    Analysis of {sup 169}Tm Moessbauer spectra recorded for (hexagonal phase) h- TmMnO{sub 3} confirms that the Mn sublattice orders magnetically below T{sub N}{sup Mn} = 82-83 K and reveals the growth of a local Tm moment at the 4b site that is induced by the Mn-Tm exchange interaction. The maximum hyperfine field recorded at the {sup 169}Tm nucleus is 312 T, which is just under half of the free ion value and corresponds to a saturation moment of 3.29 mu{sub B}. The temperature dependence of the fitted magnetic hyperfine interaction is closely represented by a simple two-singlet ground state model for the Tm{sup 3+} crystal field scheme. The saturation molecular field is deduced to lie in the range B{sub Mn-Tm}(T = 0 K) = 1.2-2.3 T, dependent on the expectation value of the coupling alpha = (0|J{sub z}|1) between the two-singlet states. As observed elsewhere for other hexagonal manganites, there is no Mn-based exchange field at the second Tm site (the 2a site) which contributes a paramagnetic subspectrum down to the lowest experimental temperature of 4.2 K.

  8. Multilayers of GaAs/Mn deposited on a substrate of GaAs (001)

    Energy Technology Data Exchange (ETDEWEB)

    Bernal-Salamanca, M; Pulzara-Mora, A; Rosales-Rivera, A [Laboratorio de Magnetismo y Materiales Avanzados, Universidad Nacional de Colombia, Sede Manizales, A.A. 127 (Colombia); Molina-Valdovinos, S; Melendez-Lira, M [Physics Department, Centro de Investigacion y Estudios Avanzados del IPN, Av. IPN No. 2508, Apartado Postal 14-740, 07000 Mexico D.F (Mexico); Lopez-Lopez, M, E-mail: aopulzaram@unal.edu.c [Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Apartado Postal 1-1010, Queretaro 76000 (Mexico)

    2009-05-01

    In this work GaAs/Mn multilayers were deposited on GaAs (001) substrates by R.F magnetron sputtering technique, varying the deposition time (tg). Scanning electron and atomic force Microscopy studies were realized on the surface of the samples in order to determine the morphology and average roughness. X-ray diffraction spectra show that our samples tend to do amorphous. Raman spectroscopy at room temperature was employed to analyze the structural properties of the samples. We found that for a GaAs film taken as reference, the Raman spectra is dominated by the transverse (TO) and longitudinal (LO) modes located at 266 cm{sup -1} and 291 cm{sup -1}, respectively. However, for the GaAs/Mn multilayers the TO and LO modes decrease dramatically, and the Mn Raman modes in the range of 100 cm{sup -1} and 250 cm{sup -1} are evidenced. Additional new peaks located around 650 and 690 cm {sup -1} are only observed for the samples with high Mn content. By using the mass reduced model we estimate that the Mn related peaks are located at 650.2 cm{sup -1} and 695.2 cm{sup -1}, in good agreement with the experimental data, these peaks are correlated with excitations due to (Mn){sub m}As{sub n} localized structures.

  9. Spin and orbital ordering in TlMnO3: Neutron diffraction study

    Science.gov (United States)

    Khalyavin, Dmitry D.; Manuel, Pascal; Yi, Wei; Belik, Alexei A.

    2016-10-01

    Crystal and magnetic structures of the high-pressure stabilized perovskite phase of TlMnO3 have been studied by neutron powder diffraction. The crystal structure involves two types of primary structural distortions: a+b-b- octahedral tilting and antiferrodistortive type of orbital ordering, whose common action reduces the symmetry down to triclinic P 1 ¯ . The orbital pattern and the way it is combined with the octahedral tilting are different from the family of LnMnO3 (Ln = lanthanide or Y) manganites who share with TlMnO3 the same tilting scheme. The experimentally determined magnetic structure with the k =(1 /2 ,0 ,1 /2 ) propagation vector and PS1 ¯ symmetry implies anisotropic exchange interactions with a ferromagnetic coupling within the (1 ,0 ,1 ¯) planes and an antiferromagnetic one between them (A type). The spins in the primary magnetic mode were found to be confined close to the (1 ,0 ,1 ¯) plane, which underlines the predominant role of the single ion anisotropy with the local easy axes of Mn3 + following the Jahn-Teller distortions of the octahedra. In spite of the same octahedral tilting scheme in the perovskite structures of both LnMnO3 and TlMnO3 manganites, a coupling of the secondary ferromagnetic component to the primary A-type spin configuration through antisymmetric exchange interaction is allowed in the former and forbidden in the latter cases.

  10. Clinical evaluation of patients with temporomandibular joint implants.

    Science.gov (United States)

    Ta, Lauren E; Phero, James C; Pillemer, Stanley R; Hale-Donze, Hollie; McCartney-Francis, Nancy; Kingman, Albert; Max, Mitchell B; Gordon, Sharon M; Wahl, Sharon M; Dionne, Raymond A

    2002-12-01

    An undetermined number of patients with temporomandibular joint (TMJ) symptoms have been treated with intra-articular disc implants composed of Teflon ethylene/propylene or Teflon polytetrafluoroethylene and aluminum oxide (Proplast-Teflon; Vitek, Houston, TX). These implants have shown the potential to fragment in situ resulting in nonbiodegradable particles that stimulate a giant cell reaction and lead to degeneration of local structures, pain, and limitation of mandibular opening. We examined the possible relationship between TMJ implants and persistent pain, responses to sensory stimuli, quality of life, and systemic immune dysfunction. This case series (32 patients) were referred from university-based orofacial pain centers and private practices from across the United States. Laboratory and clinical assessments evaluated orofacial pain symptoms, neurologic function, clinical signs and symptoms of rheumatologic disease, physical function, systemic measures of immune function, and behavioral measures. We found that TMJ implant patients appeared to have altered sensitivity to sensory stimuli, a higher number of tender points with a diagnosis of fibromyalgia, increased self-report of chemical sensitivity, higher psychologic distress and significantly lower functional ability. Systemic illness or autoimmune disease was not evident in this series of TMJ implant patients. Significant problems were noted on clinical assessment of TMJ implant patients. This is a US government work. There are no restrictions on its use.

  11. Mn(2+) is dispensable for the production of active MnP2 by Pleurotus ostreatus.

    Science.gov (United States)

    Kamitsuji, Hisatoshi; Honda, Yoichi; Watanabe, Takashi; Kuwahara, Masaaki

    2005-02-18

    The regulation mechanism for expression of versatile peroxidase MnP2 by the basidiomycete fungus Pleurotus ostreatus was examined using chemically defined synthetic media. Expression of MnP2 was down-regulated at the transcription level by nutrient nitrogen, e.g., NH(4)(+), arginine or urea. As is often the case with other fungal manganese peroxidases, active MnP2 was not detected when Mn(2+) was omitted from the culture, while mnp2 transcription was barely affected by Mn(2+). However, Mn(2+) can be substituted by an MnP2 substrate, Poly R-478, since active MnP2 was detected extracellularly when the compound was added to the culture without Mn(2+). Enzyme stability assays with the purified MnP2 indicated an indispensable requirement for a substrate that can be used to complete the catalytic cycle, and avoid inactivation resulting from an excess H(2)O(2). This report is the first of the Mn(2+)-independent production of an active versatile peroxidase by P. ostreatus.

  12. Strain in epitaxial MnSi films on Si(111) in the thick film limit studied by polarization-dependent extended x-ray absorption fine structure

    Science.gov (United States)

    Figueroa, A. I.; Zhang, S. L.; Baker, A. A.; Chalasani, R.; Kohn, A.; Speller, S. C.; Gianolio, D.; Pfleiderer, C.; van der Laan, G.; Hesjedal, T.

    2016-11-01

    We report a study of the strain state of epitaxial MnSi films on Si(111) substrates in the thick film limit (100-500 Å) as a function of film thickness using polarization-dependent extended x-ray absorption fine structure (EXAFS). All films investigated are phase-pure and of high quality with a sharp interface between MnSi and Si. The investigated MnSi films are in a thickness regime where the magnetic transition temperature Tc assumes a thickness-independent enhanced value of ≥43 K as compared with that of bulk MnSi, where Tc≈29 K . A detailed refinement of the EXAFS data reveals that the Mn positions are unchanged, whereas the Si positions vary along the out-of-plane [111] direction, alternating in orientation from unit cell to unit cell. Thus, for thick MnSi films, the unit cell volume is essentially that of bulk MnSi—except in the vicinity of the interface with the Si substrate (thin film limit). In view of the enhanced magnetic transition temperature we conclude that the mere presence of the interface, and its specific characteristics, strongly affects the magnetic properties of the entire MnSi film, even far from the interface. Our analysis provides invaluable information about the local strain at the MnSi/Si(111) interface. The presented methodology of polarization dependent EXAFS can also be employed to investigate the local structure of other interesting interfaces.

  13. Identification of the interstitial Mn site in ferromagnetic (Ga,Mn)As

    Energy Technology Data Exchange (ETDEWEB)

    Lima, T. A. L.; Augustyns, V.; Temst, K.; Vantomme, A.; Pereira, L. M. C., E-mail: lino.pereira@fys.kuleuven.be [KU Leuven, Instituut voor Kern- en Stralingsfysica, 3001 Leuven (Belgium); Wahl, U.; Costa, A.; Correia, J. G. [Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, 2686-953 Sacavém (Portugal); Silva, D. J.; Araújo, J. P. [IFIMUP and IN-Institute of Nanoscience and Nanotechnology, Universidade do Porto, 4169-007 Porto (Portugal); Houben, K.; Van Bael, M. J. [Laboratory of Solid-State Physics and Magnetism, KU Leuven, 3001 Leuven (Belgium); Edmonds, K. W.; Gallagher, B. L.; Campion, R. P. [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom); Silva, M. R. da [Centro de Física Nuclear, Universidade de Lisboa, Lisboa 1649-003 (Portugal)

    2015-01-05

    We determined the lattice location of Mn in ferromagnetic (Ga,Mn)As using the electron emission channeling technique. We show that interstitial Mn occupies the tetrahedral site with As nearest neighbors (T{sub As}) both before and after thermal annealing at 200 °C, whereas the occupancy of the tetrahedral site with Ga nearest neighbors (T{sub Ga}) is negligible. T{sub As} is therefore the energetically favorable site for interstitial Mn in isolated form as well as when forming complexes with substitutional Mn. These results shed new light on the long standing controversy regarding T{sub As} versus T{sub Ga} occupancy of interstitial Mn in (Ga,Mn)As.

  14. Implantable microwave radiators for clinical hyperthermia

    Science.gov (United States)

    Taylor, Leonard S.; Samaras, George M.; Cheung, Augustine Y.; Salcman, Michael; Scott, Ralph M.

    1982-01-01

    We describe the design of coaxial microwave radiators suitable for localized hyperthermia of neoplasia in the esophagus, brain, and other organs which are accessible through body orifices. These radiators can be implanted surgically and are small enough to be passed through such devices as nasogastric tubes and bronchoscopes. The radiators consist of combinations of cross-switched half-wavelength coaxial sections and/or needle antenna terminations. The performance of these radiators, as determined by thermogram recordings in tissue phantoms and the results of in vivo animal tests, is described.

  15. Enhancement of phase separation and superconductivity in Mn-doped K0.8Fe2-yMnySe2 crystals.

    Science.gov (United States)

    Li, M T; Chen, L; Li, Z W; Ryu, G H; Lin, C T; Zhang, J C

    2013-08-21

    Single crystals of K0.8Fe2-yMnySe2 with slight Mn doping have been grown by a self-flux method. X-ray diffraction measurements show enhanced phase separation with increasing Mn doping in the compounds. The superconducting transition temperature increases to Tc,onset ∼ 46.1 K for the sample with y ∼ 0.03, as observed by electrical transport measurements. Our results demonstrate that the doping of Mn does not suppress the superconductivity, and on the contrary increases the superconducting shield fraction and transition temperature, an effect which may originate from the Mn dopant's high preference to fill into iron vacancies in the Mn-doped samples. It suggests that the Mn dopant can induce a local lattice strain or distortion that profitably modifies the microstructure of the superconducting/metallic phase, leading to superconductivity of the compound.

  16. Double-exchange driven ferromagnetic metal-paramagnetic insulator transition in Mn-doped CuO

    Science.gov (United States)

    Filippetti, Alessio; Fiorentini, Vincenzo

    2006-12-01

    Employing ab initio self-interaction-corrected local-spin-density calculations, we explain the nature of the ferromagnetic, metallic phase of Mn-doped CuO (an antiferromagnetic insulator when undoped), and of its concurrent transitions to a paramagnetic, insulating phase. Mn-induced donor levels enable conduction through ferromagnetically aligned Mn centers and ferromagnetic CuO planes via double exchange. In the paramagnetic insulating phase, a polaron hopping mechanism consistent with the experiments is envisaged. Our results suggest the intriguing possibility of designing double-exchange driven ferromagnetic cuprates.

  17. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current...... evidence on the efficacy of psychological intervention in ICD patients and recommendations for future research....

  18. Postoperative irradiation after implant placement: A pilot study for prosthetic reconstruction

    Science.gov (United States)

    Keum, Ki Chang; Kim, Jun Won; Shim, June-Sung; Jung, Han-Sung; Park, Kyeong-Mee

    2016-01-01

    PURPOSE On maxillofacial tumor patients, oral implant placement prior to postoperative radiotherapy can shorten the period of prosthetic reconstruction. There is still lack of research on effects of post-implant radiotherapy such as healing process or loading time, which is important for prosthodontic treatment planning. Therefore, this study evaluated the effects of post-implant local irradiation on the osseointegration of implants during different healing stages. MATERIALS AND METHODS Custom-made implants were placed bilaterally on maxillary posterior edentulous area 4 weeks after extraction of the maxillary first molars in Forty-eight Sprague-Dawley rats. Experimental group (exp.) received radiation after implant surgery and the other group (control) didn't. Each group was divided into three sub-groups according to the healing time (2, 4, and 8 week) from implant placement. The exp. group 1, 2 received 15-Gy radiation 1 day after implant placement (immediate irradiation). The exp. group 3 received 15-Gy radiation 4 weeks after implant placement (delayed irradiation). RESULTS The bone mineral density (BMD) was significantly lower in the immediate irradiation groups. BMD was similar in the delayed irradiation group and the control group. The irradiated groups exhibited a lower bone-to-implant contact ratio, although the difference was not statistically significant. The irradiated groups also exhibited a significantly lower bone volume and higher empty lacuna count than the control groups. No implant failure due to local irradiation was found in this study. CONCLUSION Within the limits of this study, the timing of local irradiation critically influences the bone healing mechanism, which is related to loading time of prostheses. PMID:27826386

  19. Raman scattering studies on manganese ion-implanted GaN

    Institute of Scientific and Technical Information of China (English)

    Xu Da-Qing; Zhang Yi-Men; Zhang Yu-Ming; Li Pei-Xian; Wang Chao

    2009-01-01

    This paper reports that the Raman spectra have been recorded on the metal-organic chemical vapour deposition epitaxially grown GaN before and after the Mn ions implanted.Several Raman defect modes have emerged from the implanted samples.The structures around 182 cm-1 modes are attributed to the disorder-activated Raman scattering,whereas the 361 cm-1 and 660 cm-1 peaks are assigned to nitrogen vacancy-related defect scattering.One additional peak at 280 cm-1 is attributed to the vibrational mode of gallium vacancy-related defects and/or to disorder activated Raman scattering.A Raman-scattering study of lattice recovery is also presented by rapid thermal annealing at different temperatures between 700℃ and 1050℃ on Mn implanted GaN epilayers.The behaviour of peak-shape change and full width at half maximum(FWHM)of the A1(LO)(733 cm-1)and EH2(566 cm-1)Raman modes are explained on the basis of implantation-induced lattice damage in GaN epilayers.

  20. Polarized Raman scattering in single crystals of Nd0.7Sr0.3MnO3

    Indian Academy of Sciences (India)

    M Pattabiraman; G Rangarajan; Kwang-Yong Choi; P Lemmens; G Guentherodt; G Balakrishnan; D McK Paul; M R Less

    2002-05-01

    We report polarized Raman scattering in single crystals of Nd0.7Sr0.3MnO3. The temperature dependence of the MnO6 octahedral bending and stretching modes observed in the XX spectra points to the existence of local lattice distortions, possibly polarons. The XY spectra have been analyzed using a collision-dominated model, which allows the extraction of the carrier scattering rate.

  1. Surgical Templates for Dental Implant Positioning; Current ...

    African Journals Online (AJOL)

    applied scientifically based research techniques to develop an endosseous implant that forms ... KEYWORDS: Dental implants, surgical templates, surgical procedure, stent .... during the surgical stage for single implant therapy.[24] Afterward,.

  2. Zirconia dental implants: a literature review

    National Research Council Canada - National Science Library

    Özkurt, Zeynep; Kazazoğlu, Ender

    2011-01-01

    Titanium and titanium alloys are widely used for fabrication of dental implants. Because of potential immunologic and possible esthetic compromises with titanium implants, novel implant technologies are being developed...

  3. Scientists Design Heat-Activated Penis Implant

    Science.gov (United States)

    ... news/fullstory_162815.html Scientists Design Heat-Activated Penis Implant Device an improvement on current implants, researchers ... News) -- Doctors report that they have crafted a penis implant that becomes erect when heated. Dubbed by ...

  4. Factors affecting hydrogen-assisted cracking in a commercial tempered martensitic steel: Mn segregation, MnS, and the stress state around abnormal cracks

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Daisuke [Graduate School of Kyushu University, Fukuoka 819-0395 (Japan); Koyama, Motomichi [Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, 744 Moto-oka, Nishi-ku Fukuoka 819-0395 (Japan); Noguchi, Hiroshi, E-mail: nogu@mech.kyushu-u.ac.jp [Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, 744 Moto-oka, Nishi-ku Fukuoka 819-0395 (Japan)

    2015-07-29

    The purpose of this paper is to reveal the dominant factors affecting tensile fracture under a hydrogen gas atmosphere. Tensile tests were conducted in hydrogen gas with circumferentially-notched specimens of a commercial tempered martensitic steel. Two specimens were exposed to hydrogen gas for 48 h before tensile testing; the other two specimens were not pre-charged. Longitudinal cracks along the loading direction and a transverse crack perpendicular to the loading direction were observed on a cross section of the non-charged specimen, but there was only one small crack on a cross section of the pre-charged specimen. Electron back scatter diffraction, energy dispersive X-ray spectrometry and finite element method analyses were applied to clarify the relationships among the longitudinal crack, Mn segregation, microstructures of martensitic steel and hydrogen. As a result, it has been demonstrated that Mn segregation and MnS promote hydrogen-assisted cracking in the tempered martensitic steel, causing the longitudinal cracking which is a mechanically non-preferential direction in homogeneous situations. More specifically, we have shown that the role of the Mn segregation is to promote the hydrogen-enhanced decohesion effect (HEDE), which is particularly important for crack propagation in the present case. These considerations indicate that the presence of Mn is crucially important for hydrogen-assisted cracking associated with hydrogen-enhanced localized plasticity (HELP) as well as HEDE.

  5. Role of nitric oxide of the median preoptic nucleus (MnPO in the alterations of salivary flow, arterial pressure and heart rate induced by injection of pilocarpine into the MnPO and intraperitoneally

    Directory of Open Access Journals (Sweden)

    Wilson A. Saad

    2003-07-01

    Full Text Available We investigated the effect of L-NAME, a nitric oxide (NO inhibitor and sodium nitroprusside (SNP, an NO-donating agent, on pilocarpine-induced alterations in salivary flow, mean arterial blood pressure (MAP and heart rate (HR in rats. Male Holtzman rats (250-300 g were implanted with a stainless steel cannula directly into the median preoptic nucleus (MnPO. Pilocarpine (10, 20, 40, 80, 160 µg injected into the MnPO induced an increase in salivary secretion (P<0.01. Pilocarpine (1, 2, 4, 8, 16 mg/kg ip also increased salivary secretion (P<0.01. Injection of L-NAME (40 µg into the MnPO prior to pilocarpine (10, 20, 40, 80, 160 µg injected into the MnPO or ip (1, 2, 4, 8, 16 mg/kg increased salivary secretion (P<0.01. SNP (30 µg injected into the MnPO or ip prior to pilocarpine attenuated salivary secretion (P<0.01. Pilocarpine (40 µg injection into the MnPO increased MAP and decreased HR (P<0.01. Pilocarpine (4 mg/kg body weight ip produced a decrease in MAP and an increase in HR (P<0.01. Injection of L-NAME (40 µg into the MnPO prior to pilocarpine potentiated the increase in MAP and reduced HR (P<0.01. SNP (30 µg injected into the MnPO prior to pilocarpine attenuated (100% the effect of pilocarpine on MAP, with no effect on HR. Administration of L-NAME (40 µg into the MnPO potentiated the effect of pilocarpine injected ip. SNP (30 µg injected into the MnPO attenuated the effect of ip pilocarpine on MAP and HR. The present study suggests that in the rat MnPO 1 NO is important for the effects of pilocarpine on salivary flow, and 2 pilocarpine interferes with blood pressure and HR (side e