  1. 49 CFR 193.2181 - Impoundment capacity: LNG storage tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Impoundment capacity: LNG storage tanks. 193.2181... Impoundment capacity: LNG storage tanks. Each impounding system serving an LNG storage tank must have a minimum volumetric liquid impoundment capacity of: (a) 110 percent of the LNG tank's maximum...

  2. Comparative safety analysis of LNG storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Fecht, B.A.; Gates, T.E.; Nelson, K.O.; Marr, G.D.

    1982-07-01

    LNG storage tank design and response to selected release scenarios were reviewed. The selection of the scenarios was based on an investigation of potential hazards as cited in the literature. A review of the structure of specific LNG storage facilities is given. Scenarios initially addressed included those that most likely emerge from the tank facility itself: conditions of overfill and overflow as related to liquid LNG content levels; over/underpressurization at respective tank vapor pressure boundaries; subsidence of bearing soil below tank foundations; and crack propagation in tank walls due to possible exposure of structural material to cryogenic temperatures. Additional scenarios addressed include those that result from external events: tornado induced winds and pressure drops; exterior tank missile impact with tornado winds and rotating machinery being the investigated mode of generation; thermal response due to adjacent fire conditions; and tank response due to intense seismic activity. Applicability of each scenario depended heavily on the specific tank configurations and material types selected. (PSB)

  3. 49 CFR 193.2623 - Inspecting LNG storage tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Inspecting LNG storage tanks. 193.2623 Section 193.2623 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS... GAS FACILITIES: FEDERAL SAFETY STANDARDS Maintenance § 193.2623 Inspecting LNG storage tanks. Each...

  4. Cryogenic crashworthiness of LNG fuel storage tanks

    NARCIS (Netherlands)

    Atli-Veltin, B.; Vredeveldt, A.W.

    2014-01-01

    Shipping is gradually embracing natural gas as bunker fuel. The most viable way to store natural gas on board is in its liquid form. Gas needs to be cooled to cryogenic temperatures and in practice moderately pressurized. On board ships, solely double walled pressure tanks are used for this purpose.

  5. Cryogenic crashworthiness of LNG fuel storage tanks

    NARCIS (Netherlands)

    Atli-Veltin, B.; Vredeveldt, A.W.

    2014-01-01

    Shipping is gradually embracing natural gas as bunker fuel. The most viable way to store natural gas on board is in its liquid form. Gas needs to be cooled to cryogenic temperatures and in practice moderately pressurized. On board ships, solely double walled pressure tanks are used for this purpose.

  6. Mechanical Characteristics of 9% Ni Steel Welded Joint for Lng Storage Tank at Cryogenic

    Science.gov (United States)

    Yoon, Yong-Keun; Kim, Jae-Hoon; Shim, Kyu-Taek; Kim, Young-Kyun

    To confirm the safety performance of LNG storage tank, the change in fatigue crack growth rate and fracture toughness within X-grooved weld heat-affected zone (HAZ) of newly developed 9% Ni steel, which was SMAW welded, was investigated. These materials were produced by QT (quenching, tempering) heat treatment. The weld metal specimens were prepared by taking the same weld procedure applied in actual inner shell of LNG storage tank. All tests were performed in the temperature ranging from R.T. and -162°C. The fatigue crack growth behavior was carried out using CT specimen. Investigation has been carried out to study the influence of temperature and weld effect on fatigue crack growth behavior. Also, Fracture surfaces after tests were observe by scanning electron microscope (SEM).

  7. Pressure and Vacuum Relief Devices of Storage Tank at LNG Receiving Terminal%LNG接收站储罐压力和真空泄放装置

    Institute of Scientific and Technical Information of China (English)

    张林松; 邢贵柱

    2009-01-01

    The basic technological process of LNG receiving terminal and the basic requirement for LNG storage tank are introduced. The contents of LNG storage tank pressure test are analyzed. The facili- ties for overpressure protection and negative pressure protection of LNG storage tank,the parameter set- ting and the selection considerations,key points of design and installation of pressure and vacuum relief devices are discussed.%介绍了LNG接收站的基本工艺和LNG储罐的基本要求,分析了LNG储罐压力检测内容,论述了LNG储罐超压保护和负压保护的设施、设定参数、压力和真空泄放装置的选择依据与设计安装要点.

  8. Seismic response analysis of LNG storage tank wall under influence of inner tank%内罐影响下LNG储罐外罐地震响应分析

    Institute of Scientific and Technical Information of China (English)

    周利剑; 黄兢; 王向英; 范远刚

    2012-01-01

    In order to consider the influence of inner tank of LNG storage tank on seismic response of its outer wall, seismic response analysis of the wall of LNG storage tank with and without inner tank was carried out. Results show that the seismic response of the LNG storage tank with inner tank is smaller than that of LNG storage tank without inner one, existence of inner tank is favourable to earthquake resistance of storage tank and the influence of vertical seismic wave on vibration of the storage tank could not be neglected.%为了考虑内罐在不同方向地震动时对LNG(液化天然气)储罐外罐的影响,对有内罐和无内罐情况下LNG储罐外罐进行了地震响应分析.结果表明:有内罐时地震响应比无内罐时小,内罐的存在对LNG储罐抗震有好的影响;竖向地震波对结构振动的影响不能忽视.

  9. 大型 LNG 储罐泄漏事故后果分析%Consequence Analysis of Leakage Accident of Large LNG Storage Tank

    Institute of Scientific and Technical Information of China (English)

    俞志东; 吴建林

    2016-01-01

    Natural gas is a kind of high quality ,high efficiency ,clean energy ,Which is widely used in various industries .In order to use natural gas Conveniently ,some coastal cities in our country have built many large LNG storage tanks .Liquefied natural gas is the flammable and explosive dangerous goods ,so once a tank leaks ,it may cause very serious consequences .The PHAST software ,once being input the real scene at the time of an accident ,can calculate and analyze the diffusion ,the flash fire ,the fire disaster ,or the explosion immediately , quickly determining the leakage ,diffusion ,combustion and explosion hazard area ,and measuring the personnel death radius ,serious injury radius and minor injury radius caused by the fire thermal radiation and explosion pressure .Analysis of the accident can help receiving sta-tions intuitively understand the degree of danger after the accident so as to take corresponding measures .%天然气是一种优质、高效的清洁能源,广泛地应用于各个行业中。我国部分沿海城市已建造了大型 LNG 接收站,运用PHAST 软件,输入发生事故时的真实场景,可对 LNG 储罐泄漏事故后果进行计算和分析,从而确定泄漏、扩散、燃烧和爆炸等危险区域范围。分析结果能帮助接收站直观了解发生事故后的危险程度,进而能够针对性地采取相应的安全措施。

  10. 大型 LNG 储罐翻滚事故放空气扩散后果模拟%Simulation on diffusion consequence of vent gas in rollover accident of large LNG storage tank

    Institute of Scientific and Technical Information of China (English)

    王鹏; 王全国; 党文义; 韩中枢

    2014-01-01

    发生翻滚事故时,大型LNG储罐内压力急剧升高,为防止储罐超压破裂,大量的天然气通过安全阀放空,而天然气具有易燃易爆的特点,可能在LNG接收站的装置区及罐区发生爆炸。利用计算流体力学的方法对不同风速、风向下放空气的扩散过程进行了模拟,得到CH4的浓度分布情况。结果表明:大气风速对放空气的扩散过程具有影响,当风速逐渐增大时,降落到地面的CH4逐渐增多,而当风速超过7m/s时,随着风速的增大,降落到地面的CH4开始减少。随着风速的增大,50%LEL影响范围逐渐减小。各种风速条件下,装置区和罐区CH4的浓度均未达到50%LEL,因此LNG储罐发生翻滚事故时,放空气不会形成爆炸性气氛。%When occurring rollover accident, the pressure in the large LNG storage tank will rise sharply.In order to prevent the storage tank from overpressure and rupture, a large number of natural gas vent through the safe valve mounted on the top of tank, which may lead to explosion in the unit area and tank zones of LNG receiving station due to the flammable and explosive characteristics of natural gas.Based on the computational fluid dynamics ( CFD) technology, the diffusion processes of vent gas under different wind velocities and wind directions were sim-ulated, and the concentration distributions of CH4 were obtained.The results showed that the wind speed had an in-fluence on the diffusion process of vent gas.The amount of CH4 falling to the ground increased as the wind speed increased.If the wind speed exceeded 7m /s, the amount of CH4 fall to ground decreased as the wind speeds in-creased.50%LEL scope of CH4 decreased as the wind speed increased.Under various wind speed conditions, both the concentration of CH4 in the storage tank area and the device area did not reach 50% LEL, therefore the vent gas in rollover accident of large LNG storage tank would not form explosive

  11. FDS软件对LNG储罐泄漏火灾后果的模拟%FDS software simulation for fire consequences of LNG storage tank leaks

    Institute of Scientific and Technical Information of China (English)

    狄建华; 陈方兼

    2013-01-01

    采用FDS火灾模型软件分析了在设定的LNG火灾场景下火焰的发展规律,以广州某燃气公司3个LNG储罐中的中间储罐为研究对象,设定火灾场景,建立LNG储罐区细化模型,对火势总体情况、温度场测量点、云图动画、等值面动画、热辐射以及烟气危险区域进行模拟分析.结果表明:火灾发生时,罐区总控室附近的温度远高于危险判断值,火灾发生30 s、110 s时的危险区域范围变化较大,烟气层温度高于180℃及烟气危险等区域均出现在储罐与总控室之间的有限范围内,在人员疏散过程中应远离面向火源侧的建筑墙面.%FDS fire modeling software has been used to analyze development law of the flame in the LNG fire scenarios set. The middle one of 3 LNG storage tanks of a gas company in Guangzhou was taken as a study object to set up fire scenarios and build a refined model for LNG storage tankfarms, so as to carry out simulation analysis on overall fire situation, temperature field measuring point, cloud picture animation, isosurface animation, thermal radiation and hazardous flue gas areas. The results display that when a fire breaks out, the temperature in the vicinity of the tankfarm control room will be much higher than the danger judgement value, scope of hazardous area will follow a large change after 30 s and 110 s and the areas for smoke layer temperature higher than 180℃ and flue gas hazard will be within the limited range between the storage tank and control room. Therefore, the wall of a building facing the side of the fire source shall be kept away in the process of evacuation.

  12. Gas Storage Facilities, LP and LNG, tank farm; sparks, Published in 2006, 1:1200 (1in=100ft) scale, Washoe County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Gas Storage Facilities, LP and LNG dataset, published at 1:1200 (1in=100ft) scale, was produced all or in part from Published Reports/Deeds information as of...

  13. Analysis of temperature and pressure changes in liquefied natural gas (LNG) cryogenic tanks

    Science.gov (United States)

    Chen, Q.-S.; Wegrzyn, J.; Prasad, V.

    2004-10-01

    Liquefied natural gas (LNG) is being developed as a transportation fuel for heavy vehicles such as trucks and transit buses, to lessen the dependency on oil and to reduce greenhouse gas emissions. The LNG stations are properly designed to prevent the venting of natural gas (NG) from LNG tanks, which can cause evaporative greenhouse gas emissions and result in fluctuations of fuel flow and changes of fuel composition. Boil-off is caused by the heat added into the LNG fuel during the storage and fueling. Heat can leak into the LNG fuel through the shell of tank during the storage and through hoses and dispensers during the fueling. Gas from tanks onboard vehicles, when returned to LNG tanks, can add additional heat into the LNG fuel. A thermodynamic and heat transfer model has been developed to analyze different mechanisms of heat leak into the LNG fuel. The evolving of properties and compositions of LNG fuel inside LNG tanks is simulated. The effect of a number of buses fueled each day on the possible total fuel loss rate has been analyzed. It is found that by increasing the number of buses, fueled each day, the total fuel loss rate can be reduced significantly. It is proposed that an electric generator be used to consume the boil-off gas or a liquefier be used to re-liquefy the boil-off gas to reduce the tank pressure and eliminate fuel losses. These approaches can prevent boil-off of natural gas emissions, and reduce the costs of LNG as transportation fuel.

  14. 内罐泄漏条件下LNG储罐外罐地震响应分析%Seismic Response Analysis on Outer Wall of LNG Storage Tank under the Inner Tank Leakage Conditions

    Institute of Scientific and Technical Information of China (English)

    周利剑; 黄兢; 王向英; 范远刚

    2012-01-01

    针对内罐泄漏条件下LNG(液化天然气)储罐混凝土外罐,采用不同场地、不同方向地震波对其进行地震响应分析,得出地震波波形及方向对储罐外罐的地震响应的影响.结果表明:坚硬场地垂直向地震波对外罐加速度的影响较小,其他场地垂直向地震波对外罐的加速度影响较大,特别是软弱场地的影响最大;垂直向地震波对外罐有效应力的影响很小.%Seismic response analysis on outer wall of LNG storage tank under the inner tank leakage conditions is performed. Influence of different earthquake waveforms and the directions on tank's seismic respond is discussed. The results show that the vertical seismic wave in hard field has less influence on acceleration distribution, specially, the however vertical seismic wave in other locations has great influence on acceleration distribution specially, the impact is greatest in the soft location. The vertical seismic wave has very small effect on effective stress of the outer wall.

  15. Underground Storage Tanks - Storage Tank Locations

    Data.gov (United States)

    NSGIC Education | GIS Inventory — A Storage Tank Location is a DEP primary facility type, and its sole sub-facility is the storage tank itself. Storage tanks are aboveground or underground, and are...

  16. Effect of Heat Treatment Process on Mechanical Properties and Microstructure of a 9% Ni Steel for Large LNG Storage Tanks

    Science.gov (United States)

    Zhang, J. M.; Li, H.; Yang, F.; Chi, Q.; Ji, L. K.; Feng, Y. R.

    2013-12-01

    In this paper, two different heat treatment processes of a 9% Ni steel for large liquefied natural gas storage tanks were performed in an industrial heating furnace. The former was a special heat treatment process consisting of quenching and intercritical quenching and tempering (Q-IQ-T). The latter was a heat treatment process only consisting of quenching and tempering. Mechanical properties were measured by tensile testing and charpy impact testing, and the microstructure was analyzed by optical microscopy, transmission electron microscopy, and x-ray diffraction. The results showed that outstanding mechanical properties were obtained from the Q-IQ-T process in comparison with the Q-T process, and a cryogenic toughness with charpy impact energy value of 201 J was achieved at 77 K. Microstructure analysis revealed that samples of the Q-IQ-T process had about 9.8% of austenite in needle-like martensite, while samples of the Q-T process only had about 0.9% of austenite retained in tempered martensite.

  17. Application of medium-sized single capacity LNG storage tank in Zhuhai natural gas liquefaction plant%中型单容 LN G储罐在珠海天然气液化装置的应用

    Institute of Scientific and Technical Information of China (English)

    袁清; 姜伟强

    2014-01-01

    单容LNG储罐在中小型天然气液化装置中应用广泛,且造价低廉,但其安全性较低。静态日蒸发率的高低及压力控制系统是否能够控制储罐压力在正常范围内是衡量单容罐性能优良与否的重要表征。珠海天然气液化装置拥有两座相同的中型单容LNG储罐,从该装置的实际运行情况出发,测算了储罐的静态日蒸发率随充满率的变化情况,并分析说明造成储罐压力快速变化的原因以及压力控制系统的控制效果。%Single capacity LNG storage tanks are widely used in small and medium-sized natu-ral gas liquefaction plants .T he cost of tank is low ,but the security is poor .T he discretion of the static daily evaporation rate and w hether the pressure control system can control the tank pres-sure within the normal range are the important characterization to evaluate the performance of single capacity tank .Zhuhai LNG plant includes two medium single LNG storage tank with the same size ,based on the practical operation of the device ,the change of static daily evaporation rate with filling level were measured ,the cause of the rapid change of the tank pressure was ana-lyzed ,and the control effects of pressure control systems were demonstrated .

  18. Analysis of accidental iceberg impacts with membrane tank LNG carriers

    OpenAIRE

    Myhre, Stine Aas

    2010-01-01

    The probability of ship-iceberg impacts are increasing due to increasing production and due to more transportation routes near arctic areas. The first part of this thesis is an introduction to Liquefied Natural Gas (LNG) and the LNG carriers, particularly LNG carriers with membrane type cargo containment system.Some theory regarding the principles of Non Linear Finite Element Analysis (NLFEA) and ship-iceberg collision is briefly described.A detailed finite element model of the cargo tank is ...

  19. Evaluation of Liquid Dynamic Loads in Slack LNG Cargo Tanks

    Science.gov (United States)

    1980-05-01

    Absirect This report provides an evaluacion of dynimi,c sloshing loads in slack LNG cargo tanks. A comprehensive review of vcrid4ide scale model sloshing...Cycles at Transducer Location 1 for a 25% Full Tank .......................................... 69 IV-7 Integrated Nondimensional Pressure Values for...Location 14 for a 75% Full Tank ......................................................... 70 IV 12 Integrated Nondimensional Pressure Values for 200

  20. Research and Practice of Distributed Optical Fiber Temperature Measurement System Commissioning in LNG Storage Tank%LNG储罐分布式光纤测温系统调试研究与实践

    Institute of Scientific and Technical Information of China (English)

    张宝和

    2016-01-01

    In this paper,take distributed optical fiber temperature measurement system in Tianjin LNG storage tank for example,describes factory acceptance testing and site commissioning method for the system based on it’s work principle,and put forward the related matters that need to pay attention to in commissioning process,So as to ensure the progress and efficiency of commissioning.%本文以天津LNG储罐分布式光纤测温系统为例,在介绍工作原理的基础上,阐述了光纤测温系统的工厂验收测试及现场调试方法,并提出了调试过程中需注意的相关事项,以保障调试进度及工作效率。

  1. Testing principle of BOR and its calculation for large-scale full-capacity 16x104 m3 LNG storage tank%大型全容LNG储罐BOR测试方法与计算

    Institute of Scientific and Technical Information of China (English)

    胡小波; 魏玉迎

    2012-01-01

    以16×104 m3大型全容液化天然气储罐为例,描述其结构,介绍其静态蒸发率(BOR)的测试原理,详细论述了测试过程中的热量计算方法,并根据实测经验,对测试过程中储罐的静置、静置前相关阀位的隔离设置、现场数据测量、测后数据处理及完成测试后流程恢复进行分析梳理,提出针对此类测试的相关工艺操作建议,最后对测试结果的影响因素进行探讨,可为以后该类LNG储罐BOR的测试提供参考.%Taking the large-scale full-capacity 16×104 m3 LNG storage tank as an example, this paper describes its structure and testing principles of BOR, and analyzes the heat calculation method during the test in detail. Meanwhile, based on actual experiences, the authors analyze the parameters of tested tank in standing, relative isolation setting of valve's opening before standing, collection of field data and processing, including the recovery of technological process after testing during all test Relative suggestions about technology application in allusion to alike testing are presented. The influencing factors on testing conclusions are discussed. It is considered that the testing conclusions can be used as a reference in BOG testing of LNG tank.

  2. Oil Storage Facilities - Storage Tank Locations

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — A Storage Tank Location is a DEP primary facility type, and its sole sub-facility is the storage tank itself. Storage tanks are aboveground or underground, and are...

  3. Thermal stress and crack distribution of concrete dome of spherical LNG storage tank%LNG储罐球形混凝土穹顶的热应力及裂缝分布

    Institute of Scientific and Technical Information of China (English)

    程旭东; 孙连方; 马红; 韩明一; 张如林

    2015-01-01

    During the construction process of large-scale LNG storage tanks, the hydration heat of cement causes a great ther-mal stress to LNG storage tank dome, which leads to concrete cracking and seriously affects the durability of the dome. An improved finite element model for a large-scale LNG storage tank was established using the finite element program ADINA, and the temperature field in tank dome was determined in the process of segmented pouring of concrete, the numerical simu-lation results were compared with the field test results. The temperature field and the structure were coupled by considering concrete creep and age effects, the distributions of thermal stress and crack were determined, and the risks of concrete crack-ing were estimated. Furthermore, the sensitivity of the parameter was analyzed. The results show that a great temperature difference between the inside and the outside of the dome is generated in the process of concrete pouring, which will cause a great thermal stress. The thermal stress of the first pouring is greater than others, the hoop stress is greater than the meridian stress, and it will make the edge of dome produce meridian cracks along the circumferential direction. Types of cement have an important effects on the results of thermal stress.%对于大型LNG储罐,其穹顶因水泥水化热产生较大的热应力,引起混凝土开裂,严重影响储罐的耐久性。以某大型LNG储罐穹顶为研究对象,采用ADINA有限元软件建立精细化的有限元模型,模拟LNG储罐穹顶分段浇筑过程中的早期温度场分布,并将数值计算结果与现场测试结果进行对比;数值分析时考虑了混凝土徐变及龄期效应,对混凝土穹顶的温度场和应力场进行耦合计算,得到穹顶的热应力分布及裂缝开展情况,对穹顶混凝土开裂风险进行评估,进而对参数的敏感性进行分析。结果表明:穹顶内外在混凝土浇筑过程中产生温差较大

  4. INVESTIGATION INTO NATURAL GAS LIQUEFACTION METHODS, LNG TRANSPORT AND STORAGE

    Directory of Open Access Journals (Sweden)

    Atakan AVCI

    1995-03-01

    Full Text Available Liquefied Natural Gas (LNG processes are very new in Turkey. The Government of Turkey, due to diversification of supply and balancing of seasonal load, decided to import LNG from Algeria. The first shipment in Marmara Ereğli import terminal has been carried out in the August the 3 rd, 1994. LNG after regasification will be injected into the main transmission pipeline. The share of LNG in the world natural gas trade was approixmately 22.1% in 1988. According to the forecast, LNG share will be rapidly spreading all over the world in near future. In this paper, treatment, liquefaction, transport, storage, regasification, distribution and utilisation of LNG are examined. Particular attention has given into liquefaction of natural gas.

  5. 软土场地大型LNG储罐考虑桩土相互作用的地震响应分析%Seismic response analysis of a large LNG storage tank considering pile-soil interaction in a soft site

    Institute of Scientific and Technical Information of China (English)

    刘帅; 翁大根; 张瑞甫

    2014-01-01

    在通用有限元软件ANSYS平台上建立了桩-土-LNG储罐相互作用体系的三维整体有限元模型,分析了在IV类软土场地上考虑桩土相互作用对LNG储罐地震响应的影响。结果表明,LNG储罐的基底剪力峰值、倾覆力矩峰值和内罐壁等效应力最大值均有不同程度的减小,而最大晃动波高增大。另外还讨论了不同保温层刚度对LNG储罐地震响应的影响,通过对比发现,保温层刚度对储罐的地震响应具有重要的影响,随着保温层刚度在一定范围内的增加,基底剪力峰值、倾覆力矩峰值和最大晃动波高变化较小,但内罐壁等效应力最大值减小明显。%Based on the finite element analysis program ANSYS,a three-dimensional integral finite element model of a pile-soil-LNG storage tank interaction system was established,the effect of pile-soil interaction on the seismic response of the LNG storage tank was analyzed in a soft site of class IV.Analysis results showed that the peak shear force,the peak overturning moment and the maximum Von Mises equivalent stress of the inner steel wall of the LNG storage tank drop at different levels,but the maximum sloshing wave height of liquid rises;in addition,the effect of insulation layer stiffness on the seismic response of the LNG storage tank is also analyzed,it has an important influence on the seismic response of the LNG storage tank;with increase in insulation layer stiffness in a certain range,the peak shear force,the peak overturning moment and the maximum sloshing wave height vary a little,but the maximum Von Mises equivalent stress of the inner steel wall decreases significantly.

  6. LIQUIFIED NATURAL GAS (LNG CARRIERS

    Directory of Open Access Journals (Sweden)

    Daniel Posavec

    2010-12-01

    Full Text Available Modern liquefied natural gas carriers are double-bottom ships classified according to the type of LNG tank. The tanks are specially designed to store natural gas cooled to -161°C, the boiling point of methane. Since LNG is highly flammable, special care must be taken when designing and operating the ship. The development of LNG carriers has begun in the middle of the twentieth century. LNG carrier storage space has gradually grown to the current maximum of 260000 m3. There are more than 300 LNG carriers currently in operation (the paper is published in Croatian.

  7. Improved Polyurethane Storage Tank Performance

    Science.gov (United States)

    2014-06-30

    Figure 5.2.4 – Teen / Twenty Berm Bays from Tank 11 Corner Improved Polyurethane Storage Tank Performance Page 63 of 197 FY2009 Final Technical...5.3.9 Pump Discharge Pressure Measurement Improved Polyurethane Storage Tank Performance Page 76 of 197 FY2009 Final Technical Report...chamber pressure Improved Polyurethane Storage Tank Performance Page 173 of 197 FY2009 Final Technical Report Seaman Corporation could not be

  8. 浮式LNG接收站新建储罐冷却技术研究%Research of cooling technology for new LNG tank of floating LNG terminal

    Institute of Scientific and Technical Information of China (English)

    王晨; 杨公升; 张宝和; 贾砼; 孙谦

    2015-01-01

    本文针对浮式LNG接收站中LNG储罐的冷却过程,通过方案比选确定了冷却方式和冷却介质,介绍了冷却条件和注意事项,详细分析了从管线到储罐的冷却过程。针对冷却过程中出现的常规问题及非常规问题进行了分析并给出相应的解决方案。研究成果对其他浮式或常规LNG接收站中LNG储罐的冷却具有指导和借鉴意义。%The cooling mode and cooling medium are determined in this paper in terms of the cooling process of LNG tank for floating LNG terminal by comparison of different schemes.The cooling conditions and precautions are introduced along with the cooling process of pipeline to storage tank.The solutions for normal and abnormal issues are provided for reference of other LNG tanks’ operation.

  9. Temperature crack prediction in the construction period of a concrete outer tank for LNG storage%大型液化天然气储罐混凝土外罐施工期间温度裂缝预测

    Institute of Scientific and Technical Information of China (English)

    翟希梅; 王恒; 周庆生; 范峰

    2013-01-01

    以160000 m3大型预应力液化天然气(LNG)全容罐混凝土外罐为研究对象,在利用ANSYS软件建立精细化LNG储罐混凝土外罐有限元模型的基础上,按实际结构施工顺序与时间,模拟了LNG储罐混凝土外罐全部混凝土浇筑过程,获得了在变温条件下,由水化热作用产生的混凝土外罐早期温度场分布;在考虑混凝土收缩和徐变的条件下,采用增量法计算了混凝土外罐的早期温度应力,确定了随时间及配筋率变化的混凝土早期抗拉强度,进而对LNG储罐混凝土外罐施工阶段的裂缝发育特征及分布规律进行了预测.结果表明,混凝土收缩对温度应力影响显著,在150 d的模拟时间段内结构温度应力呈现持续增长状态;第1浇筑段的LNG外罐温度应力明显大于其他浇筑段的温度应力,且该浇筑段的罐壁在模拟期内将产生竖向裂缝,扶壁柱处将产生局部环向裂缝.该结论可为同类工程施工建造开展相应的抗裂措施提供依据.%A fine finite element model for a 160000 m3 LNG concrete tank with reasonable element types and mesh dimension was established using the finite element software (ANSYS) to simulate the actual construction process of the concrete tank.The temperature field distribution under the load of hydration heat was determined in thermal variation conditions.Considering the influence of concrete shrinkage and creep,the early thermal stress under temperature load was figured out with an incremental method,and the early tensile strength of concrete along with the reinforcement ratio and time was determined.Moreover,concrete crack growth characters and distributional rules of the LNG concrete tank were predicted by comparing thermal stress with the early tensile strength.The results showed that the concrete shrinkage has a significant effect on thermal stress,and the thermal stress of structures continues increasing during a 150-days simulation period.The thermal stress of

  10. Underground Storage Tanks in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Underground storage tank (UST) sites which store petroleum in Iowa. Includes sites which have been reported to DNR, and have active or removed underground storage...

  11. LNG储罐外墙温度应力分析及预应力筋设计%Thermal stress analyses on external wall of LNG storage tank and the design of prestressed reinforcement

    Institute of Scientific and Technical Information of China (English)

    程旭东; 朱兴吉

    2012-01-01

    The external wall of large-scale LNG storage tank is mainly built by the prestressed concrete and it has complicated stress distribution and deformation. Based on the introduction to a computing method for the thermal stress of prestressed concrete wall, we deduced computing formulae of the cylindrical wall thermal stress, the prestressed reinforcement of external wall subjected to the temperature difference load and other common loads, and locations of the maximum hoop stress by means of theoretic analyses. Consequently, a optimized scheme for prestessed reinforcement was then given. The results show that the ultra-low temperature liquid in the inner tank will produce a huge thermal stress to the prestressed concrete external wall and the maximum hoop thermal stress can reach up to a half of the tensile strength of concrete, which makes the external wall more dangerous when it is subject to internal pressure. Therefore, the temperature difference load should be considered in the design of the loop prestressed reinforcement. Numerical simulations taken afterwards by applying the automatic dynamic incremental nonlinear analysis (ADINA) finite element software to set up various discrete models of prestessed concrete verified not only the correctness of formulae deduced but also the prestessed reinforcement optimized scheme that makes the stress distribution and deformation of external wall more sound.%大型LNG储罐的外墙一般由预应力混凝土建造,其应力分布及变形比较复杂.在介绍预应力混凝土外墙温度应力计算方法的基础上,采用理论分析的方法,推导出了圆筒形外墙温度应力的计算公式,外墙在温差荷载及其他普通荷载作用下预应力筋的计算公式以及最大环向应力所在位置计算公式,进而给出了预应力筋结构调整的方案.研究结果表明,内罐的超低温液体会使预应力混凝土外墙产生很大的温度应力,环向温度应力最大可达混凝土抗拉强

  12. Development Status of Large-scale Liquefied Natural Gas (LNG) Tanks%大型液化天然气储罐的发展状况

    Institute of Scientific and Technical Information of China (English)

    张月; 王为民; 李明鑫; 郝晶; 曹彦青

    2013-01-01

    随着液化天然气的需求量日益增加,它的储存运输问题也得到了越来越大的重视。液化天然气储罐是储存液化天然气的一种重要设备。主要简介了液化天然气的优点,液化天然气储罐的分类,国内外现状,以及建造时可能遇到的问题,并简单总结了液化天然气储罐的发展趋势。%With the increasing of LNG demand,its storage and transportation problem has got more and more attention. The liquid natural gas storage tank is a kind of important equipment to store liquefied natural gas. In this article, advantages of liquefied natural gas were introduced as well as classification of LNG storage tanks. The common problems during building the liquid natural gas storage tank were discussed, and the development trend of LNG storage tanks was put forward.

  13. The sustainability of LNG evaporation

    NARCIS (Netherlands)

    Stougie, L.; Van der Kooi, H.J.

    2011-01-01

    Numerous LNG (Liquefied Natural Gas) import terminals are under construction to fulfil the growing demand for energy carriers. After storage in tanks, the LNG needs to be heated and evaporated, also called ‘regasified’, to the natural gas needed in households and industry. Several options exist for

  14. The sustainability of LNG evaporation

    NARCIS (Netherlands)

    Stougie, L.; Van der Kooi, H.J.

    2011-01-01

    Numerous LNG (Liquefied Natural Gas) import terminals are under construction to fulfil the growing demand for energy carriers. After storage in tanks, the LNG needs to be heated and evaporated, also called ‘regasified’, to the natural gas needed in households and industry. Several options exist for

  15. A large LNG tank technology system “CGTank®” of CNOOC and its engineering application

    Directory of Open Access Journals (Sweden)

    Chao Zhang

    2015-12-01

    Full Text Available LNG tanks are complex in design and building process and high in costs, so LNG tank technology is one of the most advanced ones in the field of energy, which has been monopolized by foreign companies for a long time. In order to work out LNG tank technology domestically, China National Offshore Oil Corporation (CNOOC for short, the largest LNG importer in China, develops a LNG tank technology system “CGTank®” successfully in reference to the design and construction experience of domestic and foreign companies, after years of scientific research in tackling difficult problems. This system presents four traits as follows. First, a set of calculation software is developed independently by CNOOC, and the tanks in all operating conditions are calculated after 3D hologram and multi-point contact model of fluid-solid coupling effect is built up. Second, earthquake effect research and inner tank check research are improved innovatively by means of response spectrum analysis after European standards are introduced. Third, it is put forward for the first time that the stress strength discrimination standard is based on the principal stress which is obtained by means of the maximum shearing failure theory. And fourth, a large LNG full-capacity tank technology package with completely independent intellectual property right is established. The “CGTank®” system was first applied in the Tianjin LNG demonstration project, which has passed all indicator tests and is now in operation smoothly. The project is provided with the core tank design technology by CNOOC Gas and Power Group and with the EPC by CNOOC Engineering Co., Ltd. The independent LNG tank technology can be applied in a wide scope and it is favorable for impelling domestic production of LNG industry completely.

  16. 大型LNG储罐防火间距分析%Analysis on separation distance of large LNG tank

    Institute of Scientific and Technical Information of China (English)

    闫晓; 赵东风; 孟亦飞

    2013-01-01

    国内LNG接收站产业发展日益壮大,LNG储罐的规模也随之呈现大型化的趋势,其带来对周边储罐的安全问题成为关注的焦点.针对大型LNG储罐防火间距的分析,依据国际广泛接受的美国NFPA 59A-2009和欧洲EN1473-2007标准,分别采用事故后果模拟手段和危险性评估方法确定储罐防火间距,事故场景分别考虑了罐顶池火灾和卸料管线发生直径50mm孔洞泄漏火灾.在此基础之上,对事故后果模拟得到的结果进行分析,明确储罐防火间距,从而为企业对LNG储罐区进行布局设计提供参考指导.%With the growing of domestic LNG receiving terminal industry,the size of LNG storage tank also presents large-scale trend,it causes the safety problem to surrounding tanks and becomes focus of attention.Aimed at separation distance analysis of large LNG tank,the accident consequence simulation method and risk assessment method were adopted to determine container spacing according to the international widely accepted American NFPA 59A-2009 and European EN1473-2007 standards,accident scenario were considered tank roof pool fire and leakage fire by failure of 50mm diameter hole on unloading line.On this basis,the accident consequence simulation results were analyzed,and container spacing was determined,so as to provide guidance for enterprise on the layout design of LNG tank farm.

  17. Using of polyamide in construction of supporting blocks of cryogenic tanks on example of LNG container

    Directory of Open Access Journals (Sweden)

    E. Lisowski

    2010-07-01

    Full Text Available Interest in using of cryogenic gases is increasing recently. It particularly applies to LNG (Liquefied Natural Gas, which is relatively inexpensive and environmental friendly. In the liquefied form this gas is highly compressed. One cubic meter of liquefied LNG can be expanded to 660 cubic meters of normal usable gas. At the atmospheric pressure, the liquefaction temperature of LNG is under minus 160 Celsius degrees. Therefore, there is a necessity to store it in a cryogenic tank. A system of reloading port terminals is built in several UE countries, as Spain, Italy. The LNG is delivered to these terminals using the adequately equipped ships. However, there are significant problems with delivering LNG to recipients not connected to the gas network directly. Delivering of liquefied LNG to recipients using the road or rail transport is one of the simplest solutions of this problem. This kind of transport is possible only with using suitable tanks with the adequate insulation and fulfilling the transport requirements. Many scientific research centers carry out investigations on high insulating-power materials. The problem to design and build universal container for road and rail transport was taken on by Cracow University of Technology together with the company Chemet from Tarnowskie Góry. Designed cryogenic tank is a two-walledconstruction with the vacuum between them. Distance between walls is provided by system of supporting blocks made of plastic. Thispaper presents problem of heat transfer between the walls through the supporting blocks. The investigations were carried out both:numerically, using the finite element method and experimentally, using the especially designed and built laboratory test stand, whichallowed to determine heat transfer coefficient.

  18. Energy storage-boiler tank

    Science.gov (United States)

    Chubb, T. A.; Nemecek, J. J.; Simmons, D. E.

    1980-01-01

    Activities performed in an effort to demonstrate heat of fusion energy storage in containerized salts are reported. The properties and cycle life characteristics of a eutectic salt having a boiling point of about 385 C (NaCl, KCl, Mg Cl2) were determined. M-terphenyl was chosen as the heat transfer fluid. Compatibility studies were conducted and mild steel containers were selected. The design and fabrication of a 2MWh storage boiler tank are discussed.

  19. Integral Radiator and Storage Tank

    Science.gov (United States)

    Burke, Kenneth A.; Miller, John R.; Jakupca, Ian; Sargi,Scott

    2007-01-01

    A simplified, lightweight system for dissipating heat of a regenerative fuel- cell system would include a heat pipe with its evaporator end placed at the heat source and its condenser end integrated into the wall of the regenerative fuel cell system gas-storage tanks. The tank walls act as heat-radiating surfaces for cooling the regenerative fuel cell system. The system was conceived for use in outer space, where radiation is the only physical mechanism available for transferring heat to the environment. The system could also be adapted for use on propellant tanks or other large-surface-area structures to convert them to space heat-radiating structures. Typically for a regenerative fuel cell system, the radiator is separate from the gas-storage tanks. By using each tank s surface as a heat-radiating surface, the need for a separate, potentially massive radiator structure is eliminated. In addition to the mass savings, overall volume is reduced because a more compact packaging scheme is possible. The underlying tank wall structure provides ample support for heat pipes that help to distribute the heat over the entire tank surface. The heat pipes are attached to the outer surface of each gas-storage tank by use of a high-thermal conductance, carbon-fiber composite-material wrap. Through proper choice of the composite layup, it is possible to exploit the high longitudinal conductivity of the carbon fibers (greater than the thermal conductivity of copper) to minimize the unevenness of the temperature distribution over the tank surface, thereby helping to maximize the overall heat-transfer efficiency. In a prototype of the system, the heat pipe and the composite wrap contribute an average mass of 340 g/sq m of radiator area. Lightweight space radiator panels have a mass of about 3,000 g/sq m of radiator area, so this technique saves almost 90 percent of the mass of separate radiator panels. In tests, the modified surface of the tank was found to have an emissivity of 0

  20. Leaking Underground Storage Tank (LUST) Trust Fund

    Science.gov (United States)

    In 1986, Congress created the Leaking Underground Storage Tank (LUST) Trust Fund to address releases from federally regulated underground storage tanks (USTs) by amending Subtitle I of the Solid Waste Disposal Act.

  1. INVESTIGATION INTO NATURAL GAS LIQUEFACTION METHODS, LNG TRANSPORT AND STORAGE

    OpenAIRE

    Atakan AVCI; Muhiddin CAN; Muhsin KILIÇ

    1995-01-01

    Liquefied Natural Gas (LNG) processes are very new in Turkey. The Government of Turkey, due to diversification of supply and balancing of seasonal load, decided to import LNG from Algeria. The first shipment in Marmara Ereğli import terminal has been carried out in the August the 3 rd, 1994. LNG after regasification will be injected into the main transmission pipeline. The share of LNG in the world natural gas trade was approixmately 22.1% in 1988. According to the forecast, LNG share will be...

  2. LNG-FPSO: Offshore LNG solution

    Institute of Scientific and Technical Information of China (English)

    Yan GU; Yonglin JU

    2008-01-01

    The floating production, storage and offload-ing system for liquefied natural gas (LNG-FPSO), is a new conceptual unit and an effective and realistic way for exploitation, recovery, storage, transportation and end-use applications of marginal gas fields and offshore associated-gas resources. However, a real LNG-FPSO unit cannot be built unless some breakthroughs in many key technologies are produced. Many unique characteris-tics of LNG-FPSO, such as restricted space, platform motion, LNG sloshing in inner storage tank and offload-ing system, which have not been considered in the onshore projects, are the most rigorous factors to be taken into account during design. In this paper, the overall layout of a typical LNG-FPSO unit is reviewed; the leading liquefaction technologies and processes are compared and discussed. Taking the effects of the vessel motion and limited space into account, the applicability of the main systems and key equipments of storage, offloading and power supply, are analyzed.

  3. Numerical Simulation of Sloshing in Rectangular Storage Tank Using Coupled FEM-BEM

    Institute of Scientific and Technical Information of China (English)

    Hassan Saghi; Mohammad Javad Ketabdari

    2012-01-01

    Sloshing of liquid can increase the dynamic pressure on the storage sidewalls and bottom in tanker ships and LNG careers.Different geometric shapes were suggested for storage tank to minimize the sloshing pressure on tank perimeter.In this research,a numerical code was developed to model liquid sloshing in a rectangular partially filled tank.Assuming the fluid to be inviscid,Laplace equation and nonlinear free surface boundary conditions are solved using coupled FEM-BEM.The code performance for sloshing modeling is validated against available data.To minimize the sloshing pressure on tank perimeter,rectangular tanks with specific volumes and different aspect ratios were investigated and the best aspect ratios were suggested.The results showed that the rectangular tank with suggested aspect ratios,not only has a maximum surrounded tank volume to the constant available volume,but also reduces the sloshing pressure efficiently.

  4. 19 CFR 151.44 - Storage tanks.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Storage tanks. 151.44 Section 151.44 Customs... Storage tanks. (a) Plans and gauge tables. When petroleum or petroleum products subject to duty at a specific rate per barrel are imported in bulk in tank vessels and are to be transferred into shore...

  5. Thermodynamic aspects of an LNG tank in fire and experimental validation

    Directory of Open Access Journals (Sweden)

    Hulsbosch-Dam Corina

    2017-01-01

    Full Text Available Mechanical behaviour of a Liquefied Natural Gas (LNG tank and the thermodynamic behaviour of its containment under extreme heat load – for instance when subjected to external fire source as might occur during an accident - are extremely important when addressing safety concerns. In a scenario where external fire is present and consequent release of LNG from pressure relief valves (PRV has occurred, escalation of the fire might occur causing difficulty for the fire response teams to approach the tank or to secure the perimeter. If the duration of the tank exposure to fire is known, the PRV opening time can be estimated based on the thermodynamic calculations. In this paper, such an accidental scenario is considered, relevant thermodynamic equations are derived and presented. Moreover, an experiment is performed with liquid nitrogen and the results are compared to the analytical ones. The analytical results match very well with the experimental observations. The resulting analytical models are suitable to be applied to other cryogenic liquids.

  6. Demand management of city gas per season and study of estimating proper size of LNG storage facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y.H.; Kim, S.D. [Korea Energy Economics Institute, Euiwang (Korea, Republic of)

    1997-09-01

    LNG storage facilities are indispensable to satisfy demand throughout the year by saturating the time difference of supply and demand that appears due to seasonal factors. The necessity of storage facilities is more important in a country like Korea where LNG is not produced at all and imports are relied upon. The problem of deciding how much storage facilities to keep and in what pattern to import LNG is a question to solve in order to minimize the costs related to the construction of LNG storage facilities while not causing any problem in the supply and demand of LNG. This study analyzes how the import of LNG and the consumption pattern of LNG for power generation affect the decision on the size of storage facilities. How the shipping control, and how LNG demand for power generation affect the decision of requirement of storage facilities, and why the possibility of shipping control should be investigated in the aspect of costs is investigated. As a result of this study, I presented necessary basic data for drafting a policy by assessing the minimum requirements of storage facilities needed for balancing the supply and demand with the various shipping control and LNG consumption patterns through simulation up to the year 2010. 10 refs., 33 figs., 66 tabs.

  7. Pad B Liquid Hydrogen Storage Tank

    Science.gov (United States)

    Hall, Felicia

    2007-01-01

    Kennedy Space Center is home to two liquid hydrogen storage tanks, one at each launch pad of Launch Complex 39. The liquid hydrogen storage tank at Launch Pad B has a significantly higher boil off rate that the liquid hydrogen storage tank at Launch Pad A. This research looks at various calculations concerning the at Launch Pad B in an attempt to develop a solution to the excess boil off rate. We will look at Perlite levels inside the tank, Boil off rates, conductive heat transfer, and radiant heat transfer through the tank. As a conclusion to the research, we will model the effects of placing an external insulation to the tank in order to reduce the boil off rate and increase the economic efficiency of the liquid hydrogen storage tanks.

  8. Compartmentalized storage tank for electrochemical cell system

    Science.gov (United States)

    Piecuch, Benjamin Michael (Inventor); Dalton, Luke Thomas (Inventor)

    2010-01-01

    A compartmentalized storage tank is disclosed. The compartmentalized storage tank includes a housing, a first fluid storage section disposed within the housing, a second fluid storage section disposed within the housing, the first and second fluid storage sections being separated by a movable divider, and a constant force spring. The constant force spring is disposed between the housing and the movable divider to exert a constant force on the movable divider to cause a pressure P1 in the first fluid storage section to be greater than a pressure P2 in the second fluid storage section, thereby defining a pressure differential.

  9. Kitimat LNG Inc

    Energy Technology Data Exchange (ETDEWEB)

    Boulton, R. [Kitimat LNG Inc., Calgary, AB (Canada)

    2006-07-01

    Kitimat LNG terminal is the first fully permitted liquefied natural gas (LNG) on the west coast of Canada and the United States. The terminal was designed to have a small environmental footprint, and has the full support of communities and First Nations groups in the area. Regulatory approvals are now in place, and site construction is planned to start in 2007. This presentation provided details of the facility's gas production and liquefaction processes, shipping, and LNG import and regasification terminals. The site was selected due to its deepwater, all-season port and the fact that the Pacific Trail Pipelines provide access to major transmission lines. The terminal will be comprised of an offshore LNG tanker berth and unloading jetty, a construction and tug berth, 2 LNG storage tanks, a separation unit, and send-out pipelines for natural gas and gas liquids. The terminal was designed for maximum LNG receiving flexibility as it can handle a wide variety of gas specifications and will be able to receive the largest possible LNG tankers. Market interest in the terminal has been considerable as investors are increasingly convinced that LNG can provide long-term supply alternatives to the North American gas market. Once operational the terminal will attract supply from the Pacific basin and the Middle East. Western Canadian gas demand is projected to grow at nearly 6 per cent through 2015. It was concluded that marine safety is crucial to the successful operation of the terminal. Details of safety plans formed after consultation with various organizations were presented. refs., tabs., figs.

  10. Kitimat LNG Inc.

    Energy Technology Data Exchange (ETDEWEB)

    Boulton, R. [Kitimat LNG Inc., Calgary, AB (Canada)

    2006-07-01

    Kitimat LNG terminal is the first fully permitted liquefied natural gas (LNG) on the west coast of Canada and the United States. The terminal was designed to have a small environmental footprint, and has the full support of communities and First Nations groups in the area. Regulatory approvals are now in place, and site construction is planned to start in 2007. This presentation provided details of the facility's gas production and liquefaction processes, shipping, and LNG import and regasification terminals. The site was selected due to its deepwater, all-season port and the fact that the Pacific Trail Pipelines provide access to major transmission lines. The terminal will be comprised of an offshore LNG tanker berth and unloading jetty, a construction and tug berth, 2 LNG storage tanks, a separation unit, and send-out pipelines for natural gas and gas liquids. The terminal was designed for maximum LNG receiving flexibility as it can handle a wide variety of gas specifications and will be able to receive the largest possible LNG tankers. Market interest in the terminal has been considerable as investors are increasingly convinced that LNG can provide long-term supply alternatives to the North American gas market. Once operational the terminal will attract supply from the Pacific basin and the Middle East. Western Canadian gas demand is projected to grow at nearly 6 per cent through 2015. It was concluded that marine safety is crucial to the successful operation of the terminal. Details of safety plans formed after consultation with various organizations were presented. refs., tabs., figs.

  11. Exergy of LNG regasification - possible utilization method. Case study of LNG - ANG coupling

    Science.gov (United States)

    Roszak, E. A.; Chorowski, M.

    2014-01-01

    This article gives an overview on new exergy recovery methods for LNG. The concept is based on coupling the LNG regasification unit with the filling process of Adsorbed Natural Gas (ANG) tanks. The latent heat of the LNG vaporization is directly used for precooling the ANG adsorption bed. This reduces the back pressure from filling ANG tanks due to strong adsorption temperature dependency. This improves the economic attractiveness of ANG storage (no need for compressors, longer lifetime cycle of adsorbent). This case study presents the concept of LNG - ANG coupling. Presented results are based on experimental adsorption data. A brief exergy analysis of the process shows an advantage of this method over others. This LNG-ANG method is worth consideration as a cost optimizing solution, especially for periodically working regasification stations.

  12. Underground storage tank management plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    The Underground Storage Tank (UST) Management Program at the Oak Ridge Y-12 Plant was established to locate UST systems in operation at the facility, to ensure that all operating UST systems are free of leaks, and to establish a program for the removal of unnecessary UST systems and upgrade of UST systems that continue to be needed. The program implements an integrated approach to the management of UST systems, with each system evaluated against the same requirements and regulations. A common approach is employed, in accordance with Tennessee Department of Environment and Conservation (TDEC) regulations and guidance, when corrective action is mandated. This Management Plan outlines the compliance issues that must be addressed by the UST Management Program, reviews the current UST inventory and compliance approach, and presents the status and planned activities associated with each UST system. The UST Management Plan provides guidance for implementing TDEC regulations and guidelines for petroleum UST systems. (There are no underground radioactive waste UST systems located at Y-12.) The plan is divided into four major sections: (1) regulatory requirements, (2) implementation requirements, (3) Y-12 Plant UST Program inventory sites, and (4) UST waste management practices. These sections describe in detail the applicable regulatory drivers, the UST sites addressed under the Management Program, and the procedures and guidance used for compliance with applicable regulations.

  13. Leaking Underground Storage Tank Sites in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Leaking Underground Storage Tank (LUST) sites where petroleum contamination has been found. There may be more than one LUST site per UST site.

  14. Hanford Site Waste Storage Tank Information Notebook

    Energy Technology Data Exchange (ETDEWEB)

    Husa, E.I.; Raymond, R.E.; Welty, R.K.; Griffith, S.M.; Hanlon, B.M.; Rios, R.R.; Vermeulen, N.J.

    1993-07-01

    This report provides summary data on the radioactive waste stored in underground tanks in the 200 East and West Areas at the Hanford Site. The summary data covers each of the existing 161 Series 100 underground waste storage tanks (500,000 gallons and larger). It also contains information on the design and construction of these tanks. The information in this report is derived from existing reports that document the status of the tanks and their materials. This report also contains interior, surface photographs of each of the 54 Watch List tanks, which are those tanks identified as Priority I Hanford Site Tank Farm Safety Issues in accordance with Public Law 101-510, Section 3137*.

  15. Calculation of Boil-Off Gas (BOG Generation of KC-1 Membrane LNG Tank with High Density Rigid Polyurethane Foam by Numerical Analysis

    Directory of Open Access Journals (Sweden)

    Jeong Hyeonwon

    2017-03-01

    Full Text Available Recently, a new type of LNG tank named “KC-1 membrane LNG tank” has been developed by Korean Gas Corporation (KOGAS, and Samsung Heavy Industries (SHI is currently building KC-1 membrane type LNG carriers. Unlike other LNG tanks, the KC-1 membrane LNG tank has a single-insulation structure rather than a double-insulation structure. For a given tank’s boundary condition, heat transfer analysis is performed from the external to the internal environment of the LNG tank by numerical simulation for three tanks. In each tank, the main thermally resistant layer of insulation is assembled with a High density rigid Polyurethane Foam (H-PUF, which is blown with one of three different types of hydrofluorocarbons-namely-HFC-365mfc, 245fa, and 245fa-e (enhanced. Advantage of such blowing agents is that it has a lower Ozone Depletion Potential (ODP than HCFC-141b or carbon dioxide (CO2 that has been used in the past as well as having low thermal conductivity. A Reduced Order Model is utilized to a 3-dimensional section of the insulation to calculate equivalent thermal conductivity. The equivalent thermal conductivity of the insulation is then applied to the rest of LNG tank, reducing the size of tank simulation domain as well as computation time. Tank’s two external and internal boundary conditions used are those defined by the International Code for the Construction and Equipment of Ships Carrying Liquefied Gases in Bulk (IGC and the United States Coast Guard (USCG conditions. Boil-off Rate (BOR of the tank that has the insulation with H-PUF blown with HFC-245fa resulted in 0.0927 %/day and 0.0745 %/day for IGC and USCG conditions, respectively.

  16. 40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.

    Science.gov (United States)

    2010-07-01

    ... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance...

  17. Comprehensive management of hydrocarbon storage tanks ageing

    Energy Technology Data Exchange (ETDEWEB)

    Lesueur, V.; Riethmuller, M.; Chauveau, D. [IS Services, Villepinte (France)

    2006-07-01

    Corrosion generates considerable material losses in industry and can result in irreversible damages to the environment and some times in losses in human lives. Hydrocarbon storage tanks are subject to various corrosion types like generalised corrosion resulting in large areas thickness reduction, or potentially dangerous local damage (pitting, crevice or craters). To keep safe storage conditions and save service life, it is essential: - to identify the risks by taking into account the stored products, the storage type, the environmental factors, the type of coating and the storage history, - to select the most appropriate NDT technique (acoustic emission, thickness ultrasonic measurement, TOFD, ACFM, visual inspection, remote UT..) depending on the part to be inspected and on the expected type of damage, - to propose the best solution for storage tank restoration (repair, improved protection..) - to modify the operating conditions - to define the NDT periodicity and the appropriate technique to apply according to the type of risks, to the former inspection results and to the regulation context, - to determine the remaining life of storage tank. This approach is named Comprehensive Management of hydrocarbon storage tank ageing. IS Services has developed a software called ''AGIR'' aiming at providing guidance and support to apply this approach. (orig.)

  18. Energy Policy Act of 2005 and Underground Storage Tanks (USTs)

    Science.gov (United States)

    The Energy Policy Act of 2005 significantly affected federal and state underground storage tank programs, required major changes to the programs, and is aimed at reducing underground storage tank releases to our environment.

  19. Cryogenic Storage Tank Non-Destructive Evaluation

    Science.gov (United States)

    Arens, Ellen

    2010-01-01

    This slide presentation reviews the work in non-destructive evaluation (NDE) of cryogenic storage tanks. Four large cryogenic tanks, constructed in 1965 with perlite insulation in the annular regions, are of concern. The construction of the tanks, two Liquid Oxygen (LOX) and two Liquid Hydrogen (LH2), are described. The loss rate for the LOX tank at Pad A is slightly higher than that for the one at Pad B. The concerns for the LH2 tank at Pad B are that there is a significantly higher boil-off rate than that at Pad A, that there is mold growth, indicative of increased heat flow, that there is a long down-time needed for repairs, and that 3 of 5 full thermal cycles have been used on the Pad B LH2 tank. The advantages and disadvantages of thermal imaging are given. A detailed description of what is visible of the structures in the infra-red is given and views of the thermal images are included. Missing Perlite is given as the probable cause of the cold spot on the Pad B LH2 tank. There is no indications of problematic cold regions on the Pad A LH2 tank, as shown by the thermal images given in the presentation. There is definite indication of a cold region on the Pad A LOX tank. There is however concerns with thermal imaging, as thermal images can be significantly effected by environmental conditions, image differences on similar days but with different wind speeds. Other effects that must be considered include ambient temperature, humidity levels/dew, and cloud reflections

  20. 7 CFR 58.321 - Cream storage tanks.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cream storage tanks. 58.321 Section 58.321 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....321 Cream storage tanks. Cream storage tanks shall meet the requirements of § 58.128(d). Cream...

  1. Underground Storage Tanks - UST_IDEM_IN: Underground Storage Tanks in Indiana (Indiana Department of Environmental Management, Point Shapefile)

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — UST_IDEM_IN is a point shapefile that contains regulated underground storage tank locations (including leaking underground storage tanks) in Indiana, provided by...

  2. Development of an energy storage tank model

    Science.gov (United States)

    Buckley, Robert Christopher

    A linearized, one-dimensional finite difference model employing an implicit finite difference method for energy storage tanks is developed, programmed with MATLAB, and demonstrated for different applications. A set of nodal energy equations is developed by considering the energy interactions on a small control volume. The general method of solving these equations is described as are other features of the simulation program. Two modeling applications are presented: the first using a hot water storage tank with a solar collector and an absorption chiller to cool a building in the summer, the second using a molten salt storage system with a solar collector and steam power plant to generate electricity. Recommendations for further study as well as all of the source code generated in the project are also provided.

  3. Performance analysis of liquid air energy storage utilizing LNG cold energy

    Science.gov (United States)

    Luyao, Li; Sixian, Wang; Zhang, Deng; Luwei, Yang; Yuan, Zhou; Junjie, Wang

    2017-02-01

    As the high energy density and can be stored in a long period, the liquid air is regarded as the potential energy storage medium. In the liquid air energy storage (LAES) system, liquid air is produced in the liquefaction processes by using the renewable energy or off-peak energy. The compressor is used to supply and recycle the air in liquefaction processes. In this paper, a LAES model is established, and the impact of compressor on LAES system is analysed theoretically. Liquid air energy storage (LAES) system utilizing LNG cold energy is also described. The results show that the round trip energy efficiency is enhanced and the utilizing has promising application prospect for large scale energy storage.

  4. DETERMINATION OF ECONOMIC SIZES FOR RC CYLINDRICAL WATER STORAGE TANKS

    Directory of Open Access Journals (Sweden)

    Güneş KOZLUCA

    2007-03-01

    Full Text Available Water storage tanks are built in different shapes and sizes according to needs. Designs of water storage tanks with low costs are quite important for the national economy. Cylindrical and sphere tanks are the most economic types of tanks in terms of material cost. In this study several cylindrical tank designs are made. Then most economic tank radius – tank height ratio is searched by simply changing thickness, height and the radius of the tank considered. Storage capacity of these cylindrical tanks are all the same. All these reinforced tanks have cylindrical reinforced concrete walls fixed at the bottom and free top edge without roof. It is thought that tanks constructed with this optimal ratio will be beneficial.

  5. Mediterranean region`s LNG industry. Algeria and Libya to Spain, France, Italy and Turkey; Chichukai chiiki no LNG sangyo. Arujeria, Ribia kara Supein, Furansu, Itaria, Toruko e

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-10

    Since LNG is used along with gas supply in mediterranean region, the amount of LNG use in that region is very small in comparison with total demand. However imported LNG for peak use during winter and use as industrial raw materials occupies very important part in Spain, France etc., and other importing countries. From this, further increase of LNG trade is expected. Information regarding operating conditions of plants and liquefaction ability, present conditions of base plant construction and its special features, history of oil/gas fields and LNG supply contracts with importing countries is provided for LNG exporting countries like Libya and Algeria in mediterranean region. Storage base`s scale (site area, tank capacity and ship logging`s load capacity) and period until operation starts are reported along with information before import for importing countries like Spain, France, Italy and Turkey. Further trend of base storage for Greece and Turkey will be surveyed here after.

  6. The Accident Simulation Analysis of LNG Tank%LNG储罐事故模拟分析

    Institute of Scientific and Technical Information of China (English)

    要栋梁

    2014-01-01

    Based on the software SAFETI coming from Norway Veritas, accident simulation of a liquefied natural gas storage tanks are selected. Leakage and diffusion, tank fire and explosion model was used to simulate the damage scope and impact area. It can pro-vide a theoretical basis for the emergency rescue and disaster preven-tion and mitigation.%本文应用挪威船级社的SFETI软件对某液化天然气储罐进行事故模拟,分别选用泄漏扩散、池火灾和爆炸模型进行模拟计算,得出不同事故的伤害范围和影响区域,为事故救援和防灾减灾提供了理论依据。

  7. Fluid damping of cylindrical liquid storage tanks.

    Science.gov (United States)

    Habenberger, Joerg

    2015-01-01

    A method is proposed in order to calculate the damping effects of viscous fluids in liquid storage tanks subjected to earthquakes. The potential equation of an ideal fluid can satisfy only the boundary conditions normal to the surface of the liquid. To satisfy also the tangential interaction conditions between liquid and tank wall and tank bottom, the potential flow is superimposed by a one-dimensional shear flow. The shear flow in this boundary layer yields to a decrease of the mechanical energy of the shell-liquid-system. A damping factor is derived from the mean value of the energy dissipation in time. Depending on shell geometry and fluid viscosity, modal damping ratios are calculated for the convective component.

  8. First cloud-based service for analyzing storage tank data

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-01-15

    Most commercial storage tanks are unmonitored and require manual processes to verify conditions, remediate issues or request servicing. New Boundary Technologies has developed an off-the-shelf solution that eliminates several manual processes. Its TankVista Internet service was launched as the first cloud-based service for continuously monitoring and analyzing the conditions and storage levels of commercial storage tanks, bins, silos and other containers. TankVista takes data from storage tank sensors and translates it into graphics and maps that industry can use to drive new efficiencies in storage tank management. A bulk oil distributor can leverage TankVista to remotely and continuously monitor its own storage tanks as well as those of its clients. TankVista monitors tank level, temperature, pressure, humidity and other storage criteria in order to know exactly when and where to replenish supplies. Rather than re-filling tanks at about 50 per cent capacity, a bulk oil distributor can wait until usage levels dictate more efficient re-filling. The monitoring takes place without manual intervention. TankVista complements the iDigi Tank, which has the unique ability to wirelessly connect dispersed and remote tank assets, and get this information through drop-in wireless mesh technology to the cloud without requiring onsite Internet access. 1 fig.

  9. Small Scale LNG in Europe

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    The conference has 19 presentation that addresses topics within the economic and marketing aspects, distribution and transmission, size, operation and design of LNG production units, transportation aspects, technology assessment, storage of LNG and risk and safety aspects of the use and production of LNG. Some LNG application cases are also presented.

  10. Impact resistance cryogenic bunker fuel tanks

    NARCIS (Netherlands)

    Voormeeren, L.O.; Atli-Veltin, B.; Vredeveldt, A.W.

    2014-01-01

    The increasing use of liquefied natural gas (LNG) as bunker fuel in ships, calls for an elaborate study regarding the risks involved. One particular issue is the vulnerability of cryogenic LNG storage tanks with respect to impact loadings, such as ship collisions and dropped objects. This requires a

  11. Computer modeling of ORNL storage tank sludge mobilization and mixing

    Energy Technology Data Exchange (ETDEWEB)

    Terrones, G.; Eyler, L.L.

    1993-09-01

    This report presents and analyzes the results of the computer modeling of mixing and mobilization of sludge in horizontal, cylindrical storage tanks using submerged liquid jets. The computer modeling uses the TEMPEST computational fluid dynamics computer program. The horizontal, cylindrical storage tank configuration is similar to the Melton Valley Storage Tanks (MVST) at Oak Ridge National (ORNL). The MVST tank contents exhibit non-homogeneous, non-Newtonian rheology characteristics. The eventual goals of the simulations are to determine under what conditions sludge mobilization using submerged liquid jets is feasible in tanks of this configuration, and to estimate mixing times required to approach homogeneity of the contents of the tanks.

  12. Numerical Investigations of Mixed Convection of Incompressible Viscous Fluid in LNG Storage with a Various Locations of Input and Output Mass

    Directory of Open Access Journals (Sweden)

    Sklyarenko Kristina A.

    2015-01-01

    Full Text Available The article shows the results of mathematical simulation of mixed convection in the low-temperature storage of liquefied natural gas with a regenerative cooling. The regimes of mixed convection in a closed area with the different arrangement of the input and output sections of the masses are investigated. Two-dimensional nonstationary problem in the model of the Navier-Stokes in dimensionless variables “vorticity - stream function - temperature” was examined. Are obtained distributions of the hydrodynamic parameters and temperatures, characteristic basic laws governing the processes being investigated. Detailed circulating currents and carried out analysis of the mechanism of vortices formation and the temperature distribution in the solution for mixed convection mode with low Reynolds and Grashof numbers (Gr = 106, 100 LNG storage tanks.

  13. Recommended research on LNG safety

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, H.J.; Gilmore, F.R.

    1981-03-01

    The US Department of Energy (DOE) is conducting research on the safety and other environmental aspects of liquefied energy gases including liquefied natural gas (LNG). The effort reported here was conducted as part of the planning for further research into the safety aspects of transporting and storing LNG, with primary emphasis on public safety. Although the modern LNG industry has enjoyed excellent success in providing for safe operations, significant questions remain on the part of many, the expressions of which were intensified with the addition of marine-based LNG import terminals. Public safety with regard to large-scale importation of this fuel has received widespread attention in the US Congress, state legislatures, county and city governments, and from various individuals and public groups, with coverage in all the news media, including books published on the subject. The safety concerns have centered around the consequences to the public of a large spill of the cryogenic liquid from an ocean tanker or a larger storage tank, either of which might hold as much as 125,000 m/sup 3/ of LNG.

  14. A NOVEL PROCESS TO USE SALT CAVERNS TO RECEIVE SHIP BORNE LNG

    Energy Technology Data Exchange (ETDEWEB)

    Michael M. McCall; William M. Bishop; Marcus Krekel; James F. Davis; D. Braxton Scherz

    2005-05-31

    This cooperative research project validates use of man made salt caverns to receive and store the cargoes of LNG ships in lieu of large liquid LNG tanks. Salt caverns will not tolerate direct injection of LNG because it is a cryogenic liquid, too cold for contact with salt. This research confirmed the technical processes and the economic benefits of pressuring the LNG up to dense phase, warming it to salt compatible temperatures and then directly injecting the dense phase gas into salt caverns for storage. The use of salt caverns to store natural gas sourced from LNG imports, particularly when located offshore, provides a highly secure, large scale and lower cost import facility as an alternative to tank based LNG import terminals. This design can unload a ship in the same time as unloading at a tank based terminal. The Strategic Petroleum Reserve uses man made salt caverns to securely store large quantities of crude oil. Similarly, this project describes a novel application of salt cavern gas storage technologies used for the first time in conjunction with LNG receiving. The energy industry uses man made salt caverns to store an array of gases and liquids but has never used man made salt caverns directly in the importation of LNG. This project has adapted and expanded the field of salt cavern storage technology and combined it with novel equipment and processes to accommodate LNG importation. The salt cavern based LNG receiving terminal described in the project can be located onshore or offshore, but the focus of the design and cost estimates has been on an offshore location, away from congested channels and ports. The salt cavern based terminal can provide large volumes of gas storage, high deliverability from storage, and is simplified in operation compared to tank based LNG terminals. Phase I of this project included mathematical modeling that proved a salt cavern based receiving terminal could be built at lower capital cost, and would have significantly higher

  15. Chemical Safety Alert: Catastrophic Failure of Storage Tanks

    Science.gov (United States)

    Aboveground, atmospheric storage tanks can fail when flammable vapors in the tank explode and break either the shell-to-bottom or side seam, resulting in hazardous release accidents. Proper maintenance practices can help prevent accidents.

  16. 100-N Area underground storage tank closures

    Energy Technology Data Exchange (ETDEWEB)

    Rowley, C.A.

    1993-08-01

    This report describes the removal/characterization actions concerning underground storage tanks (UST) at the 100-N Area. Included are 105-N-LFT, 182-N-1-DT, 182-N-2-DT, 182-N-3-DT, 100-N-SS-27, and 100-N-SS-28. The text of this report gives a summary of remedial activities. In addition, correspondence relating to UST closures can be found in Appendix B. Appendix C contains copies of Unusual Occurrence Reports, and validated sampling data results comprise Appendix D.

  17. 75 FR 70241 - Compatibility of Underground Storage Tank Systems With Biofuel Blends

    Science.gov (United States)

    2010-11-17

    ... AGENCY Compatibility of Underground Storage Tank Systems With Biofuel Blends AGENCY: Environmental... tank (UST) compatibility requirement as it applies to UST systems storing gasoline containing greater... underground storage tank systems greater clarity in demonstrating compatibility of their tank systems...

  18. Permanent Closure of the TAN-664 Underground Storage Tank

    Energy Technology Data Exchange (ETDEWEB)

    Bradley K. Griffith

    2011-12-01

    This closure package documents the site assessment and permanent closure of the TAN-664 gasoline underground storage tank in accordance with the regulatory requirements established in 40 CFR 280.71, 'Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.'

  19. 40 CFR 52.1931 - Petroleum storage tank controls.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Petroleum storage tank controls. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Oklahoma § 52.1931 Petroleum... plan, the petroleum storage tanks listed in paragraphs (b) through (e) of this section shall be subject...

  20. Gas Storage Facilities, LP and LNG, Tier_2_reporting_sites, Published in 2007, 1:600 (1in=50ft) scale, Buffalo County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Gas Storage Facilities, LP and LNG dataset, published at 1:600 (1in=50ft) scale, was produced all or in part from Orthoimagery information as of 2007. It is...

  1. A robotic end effector for inspection of storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, G.; Gittleman, M. [Oceaneering Space Systems, Houston, TX (United States)

    1995-10-01

    The structural integrity of waste storage tanks is of primary importance to the DOE, and is one aspect of the High-Level Waste Tank Remediation focus area. Cracks and/or corrosion damage in the inner tank walls can lead to the release of dangerous substances into the environment. The detection and sizing of corrosion and cracking in steel tank walls through remote non destructive evaluation (NDE) is the primary focus of this work.

  2. Hydrogen Peroxide Storage in Small Sealed Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, J.

    1999-10-20

    Unstabilized hydrogen peroxide of 85% concentration has been prepared in laboratory quantities for testing material compatibility and long term storage on a small scale. Vessels made of candidate tank and liner materials ranged in volume from 1 cc to 2540 cc. Numerous metals and plastics were tried at the smallest scales, while promising ones were used to fabricate larger vessels and liners. An aluminum alloy (6061-T6) performed poorly, including increasing homogeneous decay due to alloying elements entering solution. The decay rate in this high strength aluminum was greatly reduced by anodizing. Better results were obtained with polymers, particularly polyvinylidene fluoride. Data reported herein include ullage pressures as a function of time with changing decay rates, and contamination analysis results.

  3. Vehicular hydrogen storage using lightweight tanks

    Energy Technology Data Exchange (ETDEWEB)

    Mitlitsky, F; Weisberg, A H; Myers, B

    2000-07-22

    Lightweight hydrogen storage for vehicles is enabled by adopting and adapting aerospace tankage technology. The weight, volume, and cost are already acceptable and improving. Prototype tankage was demonstrated with 11.3% hydrogen by weight, 1.74 million inch (44.3 km) burst performance factor (P{sub b}V/W), and 3.77 kWh/kg specific energy for the tank and hydrogen (LHV). DOE cannot afford full scale aerospace development costs. For example, it costs many tens of $M to develop a rocket motor casing with a safety factor (SF) of 1.25. Large teams of experts are required to design, develop, and test new processes. Car companies are buying existing technology with only modest investments in research and development (R&D). The Lawrence Livermore National Laboratory (LLNL) team is maximizing the leverage from DOE funding by joining with industry to solve technical risks at the component level. LLNL is developing fabrication processes with IMPCO Technologies, Thiokol Propulsion, and Aero Tec Laboratories (ATL). LLNL is creating commercial products that are close to adoption under DOE solicitation. LLNL is breaking ground to achieve greater than 10% hydrogen by weight tankage with safety that exceeds the requirements of NGV2 standards modified for hydrogen. Risk reduction is proceeding along three axes: (1) Commercializable products will be available next year with {approx}90% confidence; (2) R&D progress is pushing the envelope in lightweight tankage for vehicles; and (3) Integration challenges are being met with partners in industry and DOE demo programs. This project is a key part of LLNL's effort to develop high cycle life energy storage systems with >600 Wh/kg specific energy for various applications, including: high altitude long endurance solar rechargeable aircraft, zero emission vehicles, hybrid energy storage/propulsion systems for spacecraft, energy storage for premium power, remote power sources, and peak shaving.

  4. Influence factors of thermal stress in the construction period of the concrete outer tank for 160 000 m3 LNG storage%160000 m3大型LNG储罐混凝土外罐施工全过程温度作用分析

    Institute of Scientific and Technical Information of China (English)

    翟希梅; 王恒

    2016-01-01

    To investigate the cracking resistance and avoid the vertical and local circumferential cracks at the bottom of the concrete outer tank during the construction period due to hydration heat, concrete shrinkage and temperature changes for 160 000 m3 liquefied natural gas ( LNG ) tanks, using the finite element numerical simulation technology, the influence of shuttering material, construction quality, construction season and pouring temperature on cracks was figured out with an incremental method. The results show that concrete shrinkage leads to a sustaind growth of concrete tensile stress, the thermal stress fluctuates according to the changing of construction temperature and construction quality and construction season have a strong inference on cracks. Based on this basis, the thermal tress is dismantled according to the effect of each influencing factor, and the whole thermal stress is the superposition of the thermal stress under single influence of hydration heat, concrete shrinkage, construction season and pouring temperature. Some suggestions on anti⁃cracking measures are proposed, mainly by regulating the construction season, complementally by improving the quality of construction.%为了解160000 m3大型液化天然气( LNG)储罐混凝土外罐在施工期间的抗裂性能,避免由于水泥水化放热、混凝土收缩、外界气温变化而造成的外罐墙壁竖向开裂及扶壁柱局部环向裂缝现象,运用有限元数值模拟技术,采用增量法,分别探讨了施工模板材料、施工质量、施工季节及混凝土入模温度对混凝土外罐温度应力分布的影响及其规律。结果显示:模板对温度应力的影响作用较小,混凝土收缩导致混凝土拉应力持续增长,温度应力随着施工季节温度的变化而产生相应波动,施工质量及施工季节对温度应力的影响较大;在上述结论基础上,视温度应力结果为水化热、混凝土收缩、外界

  5. Membrane Tank Lng Carriers Les méthaniers à membrane

    Directory of Open Access Journals (Sweden)

    Chauvin J. M.

    2006-11-01

    Full Text Available This document describes the two membranes containment systems developed by the company Gaztransport & Technigaz for the transportation at sea of liquefied natural gas (LNG and applied by several shipyards in Europe, United States, Japan and Korea. The merits of both containment systems are underlined with respect to the competition for operating flexibility as well as safety during LNG carrier operation. Finally, the merits of both containment systems in terms of construction and coasts are presented. Cet article présente les deux techniques membranes proposées par la société Gaztransport & Technigaz pour le transport par mer de gaz naturel liquéfié (GNL et mises en oeuvre par les chantiers navals européens, américains, japonais et coréens. Il souligne les avantages de ces techniques par rapport aux techniques concurrentes, aussi bien du point de vue opérationnel que sur le plan de la sécurité en cours d'exploitation du navire méthanier. Enfin, il présente également les mérites de ces techniques en termes de coûts de construction, d'investissement et délais de réalisation.

  6. Attenuating water hammer pressure by means of gas storage tank

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The basic equations for computing the volume of gas storage tank were derived from the principles of attenuating water hammer pressure. Verifications using experiments indicate that the proposed equation can provide a fare precision in the predictions. By using the model of solid-liquid two-phase flow, the gas storage tank, pressure-relief valves and slow-closure reverse-control valves were compared with practical engineering problems, and the functions of gas storage tank in attenuating water hammer pressure were further investigated.

  7. Stud welding for fixation of cryogenic insulation of membrane tanks in LNG ship building

    Institute of Scientific and Technical Information of China (English)

    Jeong-Soo LEE; Young-Soo RYU; Nam-In KIM; Bong-Joon KIM; Yoo-Kyung KIM; Myung-Hyun KIM

    2009-01-01

    The support plates including all of the inner hulls such as E grade steel, weld seams and SUS304L were considered to establish the optimal stud welding condition in LNG ship building. The stainless steel plate was especially applied to the bracket on the liquid dome. The polished and etched surfaces of the welded stud and support plate were examined if the bead was properly formed. With the micrographic examination, the fusion boundary of metal weld zone formed by stud welding was analyzed to optimize the welding parameters. And also the analysis of the unacceptable welding faults such as cold and hot weld were performed. The mechanical tests such as tensile tests and bending tests were carried out to reveal any abnormal variation in the relationship of process parameters and the strength.

  8. Glass Bubbles Insulation for Liquid Hydrogen Storage Tanks

    Science.gov (United States)

    Sass, J. P.; SaintCyr, W. W.; Barrett, T. M.; Baumgartner, R. G.; Lott, J. W.; Fesmire, J. E.

    2009-01-01

    A full-scale field application of glass bubbles insulation has been demonstrated in a 218,000 L liquid hydrogen storage tank. This work is the evolution of extensive materials testing, laboratory scale testing, and system studies leading to the use of glass bubbles insulation as a cost efficient and high performance alternative in cryogenic storage tanks of any size. The tank utilized is part of a rocket propulsion test complex at the NASA Stennis Space Center and is a 1960's vintage spherical double wall tank with an evacuated annulus. The original perlite that was removed from the annulus was in pristine condition and showed no signs of deterioration or compaction. Test results show a significant reduction in liquid hydrogen boiloff when compared to recent baseline data prior to removal of the perlite insulation. The data also validates the previous laboratory scale testing (1000 L) and full-scale numerical modeling (3,200,000 L) of boiloff in spherical cryogenic storage tanks. The performance of the tank will continue to be monitored during operation of the tank over the coming years. KEYWORDS: Glass bubble, perlite, insulation, liquid hydrogen, storage tank.

  9. Underground storage tank 511-D1U1 closure plan

    Energy Technology Data Exchange (ETDEWEB)

    Mancieri, S.; Giuntoli, N.

    1993-09-01

    This document contains the closure plan for diesel fuel underground storage tank 511-D1U1 and appendices containing supplemental information such as staff training certification and task summaries. Precision tank test data, a site health and safety plan, and material safety data sheets are also included.

  10. Indian Country Leaking Underground Storage Tanks, Region 9, 2016

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains point features that represent Leaking Underground Storage Tanks in US EPA Region 9 Indian Country. This dataset contains facility name and...

  11. Inspecting Underground Storage Tanks - 2005 Energy Policy Act

    Science.gov (United States)

    these grant guidelines implement the inspection provisions in Sections 9005(c)(1) and 9005(c)(2) of the Solid Waste Disposal Act, enacted by the Underground Storage Tank Compliance Act, part of the Energy Policy Act of 2005.

  12. Public Record About Underground Storage Tanks - 2005 Energy Policy Act

    Science.gov (United States)

    These grant guidelines implement the public record provision in Section 9002(d) of the Solid Waste Disposal Act, enacted by the Underground Storage Tank Compliance Act, part of the Energy Policy Act of 2005.

  13. Application and maintenance of tank instrument system in Jiangsu LNG project%罐表系统在江苏LNG项目的应用与维护

    Institute of Scientific and Technical Information of China (English)

    黄亮

    2012-01-01

    Honeywell tank instrument system is used first time in LNG project in China. The paper introduces the system composition in detail, and describes the servo level gauge, including working principles of its accessories and the application and maintenance, the working principles and maintenance of servo level gauge, tracing liquid level, density and temperature monitoring of LTD, RTD monitoring temperature of tank surface and leakage, the high liquid level alarming set to protect tank, liquid level radar gauge as interlock, and the communication transmission lines and data conversion equipment. The authors point out that the experiences in the application and maintenance of tank instrument system in Jiangsu LNG project can provide a guideline to the operation of the tank instrument system in other LNG programs in China.%Honerwell罐表系统首次在国内LNG项目中应用.系统介绍了该罐表系统的组成,描述了测量液位的伺服液位计及其附件的工作原理与应用维护,跟踪液位并可监控各个位置液体密度和温度的LTD的工作原理与维护事项,监控储罐表面温度和泄漏情况的电阻式温度检测器(Resistance Temperature Detector,RTD)、为保护储罐而设置的高液位报警、参与联锁控制的雷达液位计以及通讯传输线缆和数据转换设备等的应用.罐表系统在江苏LNG接收站的应用与维护经验可为国内其他LNG项目罐表系统的运行提供指导.

  14. Study of Heat Transfer in Ice-storage Tank

    Institute of Scientific and Technical Information of China (English)

    Anding He; Huanqun Qian; Zhihua Hu; Fangde Zhou

    2001-01-01

    The heat transfer process of ice formation on the outside of coil pipe in the ice storage tank with glycol solution as the second refrigerant was studied in this paper analytically and experimentally. A model was developed for the charging process and the conduction shape factor was applied. Also, the result obtained from the model was compared with the experimental data, both data were in agreement. The simple model is useful for the operation, design and optimization of the ice storage tank.

  15. 46 CFR 154.703 - Methane (LNG).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Methane (LNG). 154.703 Section 154.703 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR... and Temperature Control § 154.703 Methane (LNG). Unless a cargo tank carrying methane (LNG)...

  16. Solar Storage Tank Insulation Influence on the Solar Systems Efficiency

    Directory of Open Access Journals (Sweden)

    Negoitescu Arina

    2012-09-01

    Full Text Available For the storage tank of a solar system for domestic hot water production was analyzed the insulation thickness and material influence. To this end, it was considered a private house, occupied by 3 persons, located in zone I of thermal radiation, for which has been simulated the domestic hot water production process. The tank outlet hot water temperature was considered of 45°C. For simulation purposes, as insulation materials for the storage tank were taking into account glass wool and polyurethane with various thicknesses. Finally, was carried out the comparative analysis of two types of tanks, in terms of the insulation thickness influence on the solar fraction, annual solar contribution and solar annual productivity. It resulted that polyurethane is the most advantageous from all points of view.

  17. Seismic Analysis of Reinforced Concrete Shaft Support Water Storage Tank

    Directory of Open Access Journals (Sweden)

    Bharti Tekwani

    2016-05-01

    Full Text Available This paper compares the results of Seismic Analysis of Reinforced Concrete Shaft Support Water Storage Tank carried out in accordance with IS: 1893- 1984 and IS: 1893-2002 (Part-2 draft code. The analysis is carried out for shaft supported water tank of 500,750 and 1000 Cu.m capacity, located in four seismic zones (Zone-II, Zone -III, Zone-IV, Zone-V and on three different soil types (Hard rock, Medium soil, Soft soil. Further, 1000 kl tank for conditions - tank full, tank empty are also considered in this study. The analysis was performed using MAT LAB. The parameters of comparison include base shears, base moments and time history analysis. The above models are analyzed for different time history data such as El Centro, Kobe, Ji-Ji, Erzincan. The comparison is made between the structural responses of one mass and two mass models of above capacity.

  18. Case Study in Corporate Memory Recovery: Hanford Tank Farms Miscellaneous Underground Waste Storage Tanks - 15344

    Energy Technology Data Exchange (ETDEWEB)

    Washenfelder, D. J.; Johnson, J. M.; Turknett, J. C.; Barnes, T. J.; Duncan, K. G.

    2015-01-07

    In addition to managing the 177 underground waste storage tanks containing 212,000 m3 (56 million gal) of radioactive waste at the U. S. Department of Energy’s Hanford Site 200 Area Tank Farms, Washington River Protection Solutions LLC is responsible for managing numerous small catch tanks and special surveillance facilities. These are collectively known as “MUSTs” - Miscellaneous Underground Storage Tanks. The MUSTs typically collected drainage and flushes during waste transfer system piping changes; special surveillance facilities supported Tank Farm processes including post-World War II uranium recovery and later fission product recovery from tank wastes. Most were removed from service following deactivation of the single-shell tank system in 1980 and stabilized by pumping the remaining liquids from them. The MUSTs were isolated by blanking connecting transfer lines and adding weatherproofing to prevent rainwater entry. Over the next 30 years MUST operating records were dispersed into large electronic databases or transferred to the National Archives Regional Center in Seattle, Washington. During 2014 an effort to reacquire the historical bases for the MUSTs’ published waste volumes was undertaken. Corporate Memory Recovery from a variety of record sources allowed waste volumes to be initially determined for 21 MUSTs, and waste volumes to be adjusted for 37 others. Precursors and symptoms of Corporate Memory Loss were identified in the context of MUST records recovery.

  19. Soil load above Hanford waste storage tanks (2 volumes)

    Energy Technology Data Exchange (ETDEWEB)

    Pianka, E.W. [Advent Engineering Services, Inc., San Ramon, CA (United States)

    1995-01-25

    This document is a compilation of work performed as part of the Dome Load Control Project in 1994. Section 2 contains the calculations of the weight of the soil over the tank dome for each of the 75-feet-diameter waste-storage tanks located at the Hanford Site. The chosen soil specific weight and soil depth measured at the apex of the dome crown are the same as those used in the primary analysis that qualified the design. Section 3 provides reference dimensions for each of the tank farm sites. The reference dimensions spatially orient the tanks and provide an outer diameter for each tank. Section 4 summarizes the available soil surface elevation data. It also provides examples of the calculations performed to establish the present soil elevation estimates. The survey data and other data sources from which the elevation data has been obtained are printed separately in Volume 2 of this Supporting Document. Section 5 contains tables that provide an overall summary of the present status of dome loads. Tables summarizing the load state corresponding to the soil depth and soil specific weight for the original qualification analysis, the gravity load requalification for soil depth and soil specific weight greater than the expected actual values, and a best estimate condition of soil depth and specific weight are presented for the Double-Shell Tanks. For the Single-Shell Tanks, only the original qualification analysis is available; thus, the tabulated results are for this case only. Section 6 provides a brief overview of past analysis and testing results that given an indication of the load capacity of the waste storage tanks that corresponds to a condition approaching ultimate failure of the tank. 31 refs.

  20. Petroleum storage tank cleaning using commercial microbial culture products

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, D.R.; Entzeroth, L.C.; Timmis, A.; Whiteside, A.; Hoskins, B.C.

    1995-12-31

    The removal of paraffinic bottom accumulations from refinery storage tanks represents an increasingly costly area of petroleum storage management. Microorganisms can be used to reduce paraffinic bottoms by increasing the solubility of bottom material and by increasing the wax-carrying capacity of carrier oil used in the cleaning process. The economic savings of such treatments are considerable. The process is also intrinsically safer than alternative methods, as it reduces and even eliminates the need for personnel to enter the tank during the cleaning process. Both laboratory and field sample analyses can be used to document changes in tank material during the treatment process. These changes include increases in volatile content and changes in wax distribution. Several case histories illustrating these physical and chemical changes are presented along with the economics of treatment.

  1. China's Largest Oil Storage Tanks Put into Service

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ Two 125,000-cubic-meter and 90-meter-diameter crude storage tanks, currently largest ones in China,have been constructed and put into service at Sinopec's Maoming Petrochemical Harbor Company in Southeast China's Guangdong Province in recent time.

  2. K Basins sludge removal temporary sludge storage tank system

    Energy Technology Data Exchange (ETDEWEB)

    Mclean, M.A.

    1997-06-12

    Shipment of sludge from the K Basins to a disposal site is now targeted for August 2000. The current path forward for sludge disposal is shipment to Tank AW-105 in the Tank Waste Remediation System (TWRS). Significant issues of the feasibility of this path exist primarily due to criticality concerns and the presence of polychlorinated biphenyls (PCBS) in the sludge at levels that trigger regulation under the Toxic Substance Control Act. Introduction of PCBs into the TWRS processes could potentially involve significant design and operational impacts to both the Spent Nuclear Fuel and TWRS projects if technical and regulatory issues related to PCB treatment cannot be satisfactorily resolved. Concerns of meeting the TWRS acceptance criteria have evolved such that new storage tanks for the K Basins sludge may be the best option for storage prior to vitrification of the sludge. A reconunendation for the final disposition of the sludge is scheduled for June 30, 1997. To support this decision process, this project was developed. This project provides a preconceptual design package including preconceptual designs and cost estimates for the temporary sludge storage tanks. Development of cost estimates for the design and construction of sludge storage systems is required to help evaluate a recommendation for the final disposition of the K Basin sludge.

  3. 考虑货舱绝热层压力的薄膜型LNG 船相关操作要领%Related Operation Essentials of Membrane Types LNG Carriers on Considering the Pressure of Cargo Tank and Insulation Space

    Institute of Scientific and Technical Information of China (English)

    何庆华; 尹建川; 章文俊

    2015-01-01

    针对No 96和Mark III两种薄膜型LNG船的屏壁非常薄,承受压力的范围有限的问题,为保证货舱安全,比较分析这两种船型的货物围护系统、货舱和主次绝热层正常压力范围,以及引起压力过高和过低的原因,介绍货舱压力升高、降低可能触发的报警,总结薄膜型LNG船货物操作过程中应注意的问题。%Considering the pressure of cargo tanks of membrane type LNG carrier including No 96 and Mark III can bear is limited due to their very thin barriers, in order to protect cargo tanks, cargo containment systems of the two types of LNG carriers are interpreted, as well as the routine working pressure range of cargo tanks and insulation spaces of these two membrane types LNG carrier.The reasons of over pressure and under pressure are also presented.The alarms may be activated due to high or low pressure of cargo tanks are specified, and the precautions to be paid during cargo operations for LNG carrier are summarized.

  4. Technical bases for leak detection surveillance of waste storage tanks. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, M.G.; Badden, J.J.

    1995-02-13

    This document provides the technical bases for specification limits, monitoring frequencies and baselines used for leak detection and intrusion (for single shell tanks only) in all single and double shell radioactive waste storage tanks, waste transfer lines, and most catch tanks and receiver tanks in the waste tank farms and associated areas at Hanford.

  5. Ice slurry cooling research: Storage tank ice agglomeration and extraction

    Energy Technology Data Exchange (ETDEWEB)

    Kasza, K. [Argonne National Lab., IL (United States); Hayashi, Kanetoshi [NKK Corp., Kawasaki (Japan)

    1999-08-01

    A new facility has been built to conduct research and development on important issues related to implementing ice slurry cooling technology. Ongoing studies are generating important information on the factors that influence ice particle agglomeration in ice slurry storage tanks. The studies are also addressing the development of methods to minimize and monitor agglomeration and improve the efficiency and controllability of tank extraction of slurry for distribution to cooling loads. These engineering issues impede the utilization of the ice slurry cooling concept that has been under development by various groups.

  6. Integrated heat exchanger design for a cryogenic storage tank

    Energy Technology Data Exchange (ETDEWEB)

    Fesmire, J. E.; Bonner, T.; Oliveira, J. M.; Johnson, W. L.; Notardonato, W. U. [NASA Kennedy Space Center, Cryogenics Test Laboratory, NE-F6, KSC, FL 32899 (United States); Tomsik, T. M. [NASA Glenn Research Center, 21000 Brookpark Road, Cleveland, OH 44135 (United States); Conyers, H. J. [NASA Stennis Space Center, Building 3225, SSC, MS 39529 (United States)

    2014-01-29

    Field demonstrations of liquid hydrogen technology will be undertaken for the proliferation of advanced methods and applications in the use of cryofuels. Advancements in the use of cryofuels for transportation on Earth, from Earth, or in space are envisioned for automobiles, aircraft, rockets, and spacecraft. These advancements rely on practical ways of storage, transfer, and handling of liquid hydrogen. Focusing on storage, an integrated heat exchanger system has been designed for incorporation with an existing storage tank and a reverse Brayton cycle helium refrigerator of capacity 850 watts at 20 K. The storage tank is a 125,000-liter capacity horizontal cylindrical tank, with vacuum jacket and multilayer insulation, and a small 0.6-meter diameter manway opening. Addressed are the specific design challenges associated with the small opening, complete modularity, pressure systems re-certification for lower temperature and pressure service associated with hydrogen densification, and a large 8:1 length-to-diameter ratio for distribution of the cryogenic refrigeration. The approach, problem solving, and system design and analysis for integrated heat exchanger are detailed and discussed. Implications for future space launch facilities are also identified. The objective of the field demonstration will be to test various zero-loss and densified cryofuel handling concepts for future transportation applications.

  7. Estimating Residual Solids Volume In Underground Storage Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Jason L.; Worthy, S. Jason; Martin, Bruce A.; Tihey, John R.

    2014-01-08

    The Savannah River Site liquid waste system consists of multiple facilities to safely receive and store legacy radioactive waste, treat, and permanently dispose waste. The large underground storage tanks and associated equipment, known as the 'tank farms', include a complex interconnected transfer system which includes underground transfer pipelines and ancillary equipment to direct the flow of waste. The waste in the tanks is present in three forms: supernatant, sludge, and salt. The supernatant is a multi-component aqueous mixture, while sludge is a gel-like substance which consists of insoluble solids and entrapped supernatant. The waste from these tanks is retrieved and treated as sludge or salt. The high level (radioactive) fraction of the waste is vitrified into a glass waste form, while the low-level waste is immobilized in a cementitious grout waste form called saltstone. Once the waste is retrieved and processed, the tanks are closed via removing the bulk of the waste, chemical cleaning, heel removal, stabilizing remaining residuals with tailored grout formulations and severing/sealing external penetrations. The comprehensive liquid waste disposition system, currently managed by Savannah River Remediation, consists of 1) safe storage and retrieval of the waste as it is prepared for permanent disposition; (2) definition of the waste processing techniques utilized to separate the high-level waste fraction/low-level waste fraction; (3) disposition of LLW in saltstone; (4) disposition of the HLW in glass; and (5) closure state of the facilities, including tanks. This paper focuses on determining the effectiveness of waste removal campaigns through monitoring the volume of residual solids in the waste tanks. Volume estimates of the residual solids are performed by creating a map of the residual solids on the waste tank bottom using video and still digital images. The map is then used to calculate the volume of solids remaining in the waste tank. The

  8. Cathodic protection for the bottoms of above ground storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, John P. [Tyco Adhesives, Norwood, MA (United States)

    2004-07-01

    Impressed Current Cathodic Protection has been used for many years to protect the external bottoms of above ground storage tanks. The use of a vertical deep ground bed often treated several bare steel tank bottoms by broadcasting current over a wide area. Environmental concerns and, in some countries, government regulations, have introduced the use of dielectric secondary containment liners. The dielectric liner does not allow the protective cathodic protection current to pass and causes corrosion to continue on the newly placed tank bottom. In existing tank bottoms where inadequate protection has been provided, leaks can develop. In one method of remediation, an old bottom is covered with sand and a double bottom is welded above the leaking bottom. The new bottom is welded very close to the old bottom, thus shielding the traditional cathodic protection from protecting the new bottom. These double bottoms often employ the use of dielectric liner as well. Both the liner and the double bottom often minimize the distance from the external tank bottom. The minimized space between the liner, or double bottom, and the bottom to be protected places a challenge in providing current distribution in cathodic protection systems. This study examines the practical concerns for application of impressed current cathodic protection and the types of anode materials used in these specific applications. One unique approach for an economical treatment using a conductive polymer cathodic protection method is presented. (author)

  9. Safety of atmospheric storage tanks during accidental explosions

    OpenAIRE

    Noret, E.; Prod'Homme, Gaëtan; Yalamas, Thierry; Reimeringer, Mathieu; Hanus, Jean-Luc; Duong, Duy-Hung

    2012-01-01

    International audience; The occurrence of a chain reaction from blast on atmospheric storage tanks in oil and chemical facilities is hard to predict. The current French practice for SEVESO facilities ignores projectiles and assumes a critical peak overpressure value observed from accident data. This method could lead to conservative or dangerous assessments. This study presents various simple mechanical models to facilitate quick effective assessment of risk analysis, the results of which are...

  10. Fluid manifold design for a solar energy storage tank

    Science.gov (United States)

    Humphries, W. R.; Hewitt, H. C.; Griggs, E. I.

    1975-01-01

    A design technique for a fluid manifold for use in a solar energy storage tank is given. This analytical treatment generalizes the fluid equations pertinent to manifold design, giving manifold pressures, velocities, and orifice pressure differentials in terms of appropriate fluid and manifold geometry parameters. Experimental results used to corroborate analytical predictions are presented. These data indicate that variations in discharge coefficients due to variations in orifices can cause deviations between analytical predictions and actual performance values.

  11. Chile exploits LNG

    Energy Technology Data Exchange (ETDEWEB)

    1980-03-01

    Simultaneously with its exploitation of offshore hydrocarbon reservoirs Chile is developing the production and selling of LNG. Chile produces a large quantity of associated gas from its reservoirs at Megallanes and processes it at the Manantiales, Cullen and Posesion plants recovering propane, butane and natural gas liguids. The stripped gas is reinjected for pressure maintenance operations. With the completion of the LNG program full use of the gas will be achieved. It will totally meet the needs of combustible liquids for the central and northern parts of the country, a volume of 2200 million cu m/yr. For its treatment natural gas is sent through gas pipelines to the LNG plant at Cabo Negro. By means of a cooling process, the gas is cooled to -160 C where it becomes a liquid and its volume is reduced by a factor of 600. It is then stored in tanks at atmospheric pressure.

  12. Implementation of lng as marine fuel in current vessels : Perspectives and improvements on their environmental efficiency

    OpenAIRE

    Sastre Buades, Llorenç

    2017-01-01

    Liquefied Natural Gas (LNG) as marine fuel currently appears to be an attractive, potential and technically feasible option for new building vessels to comply with air pollution regulations. Consequently, the implementation of LNG on board vessels has been conducted together with the development of LNG-fuelled engines, LNG fuel tanks, gas supply systems and LNG infrastructure. LNG-fuelled vessels are equipped principally with lean-burn gas engines or dual-fuel (DF) engines, vacuum insulated C...

  13. A NOVEL PROCESS TO USE SALT CAVERNS TO RECEIVE SHIP BORNE LNG

    Energy Technology Data Exchange (ETDEWEB)

    Michael M. McCall; William M. Bishop; Marcus Krekel; James F. Davis; D. Braxton Scherz

    2005-05-31

    This cooperative research project validates use of man made salt caverns to receive and store the cargoes of LNG ships in lieu of large liquid LNG tanks. Salt caverns will not tolerate direct injection of LNG because it is a cryogenic liquid, too cold for contact with salt. This research confirmed the technical processes and the economic benefits of pressuring the LNG up to dense phase, warming it to salt compatible temperatures and then directly injecting the dense phase gas into salt caverns for storage. The use of salt caverns to store natural gas sourced from LNG imports, particularly when located offshore, provides a highly secure, large scale and lower cost import facility as an alternative to tank based LNG import terminals. This design can unload a ship in the same time as unloading at a tank based terminal. The Strategic Petroleum Reserve uses man made salt caverns to securely store large quantities of crude oil. Similarly, this project describes a novel application of salt cavern gas storage technologies used for the first time in conjunction with LNG receiving. The energy industry uses man made salt caverns to store an array of gases and liquids but has never used man made salt caverns directly in the importation of LNG. This project has adapted and expanded the field of salt cavern storage technology and combined it with novel equipment and processes to accommodate LNG importation. The salt cavern based LNG receiving terminal described in the project can be located onshore or offshore, but the focus of the design and cost estimates has been on an offshore location, away from congested channels and ports. The salt cavern based terminal can provide large volumes of gas storage, high deliverability from storage, and is simplified in operation compared to tank based LNG terminals. Phase I of this project included mathematical modeling that proved a salt cavern based receiving terminal could be built at lower capital cost, and would have significantly higher

  14. [Study on the quantitative estimation method for VOCs emission from petrochemical storage tanks based on tanks 4.0.9d model].

    Science.gov (United States)

    Li, Jing; Wang, Min-Yan; Zhang, Jian; He, Wan-Qing; Nie, Lei; Shao, Xia

    2013-12-01

    VOCs emission from petrochemical storage tanks is one of the important emission sources in the petrochemical industry. In order to find out the VOCs emission amount of petrochemical storage tanks, Tanks 4.0.9d model is utilized to calculate the VOCs emission from different kinds of storage tanks. VOCs emissions from a horizontal tank, a vertical fixed roof tank, an internal floating roof tank and an external floating roof tank were calculated as an example. The consideration of the site meteorological information, the sealing information, the tank content information and unit conversion by using Tanks 4.0.9d model in China was also discussed. Tanks 4.0.9d model can be used to estimate VOCs emissions from petrochemical storage tanks in China as a simple and highly accurate method.

  15. Criticality Safety Evaluation of Hanford Site High Level Waste Storage Tanks

    Energy Technology Data Exchange (ETDEWEB)

    ROGERS, C.A.

    2000-02-17

    This criticality safety evaluation covers operations for waste in underground storage tanks at the high-level waste tank farms on the Hanford site. This evaluation provides the bases for criticality safety limits and controls to govern receipt, transfer, and long-term storage of tank waste. Justification is provided that a nuclear criticality accident cannot occur for tank farms operations, based on current fissile material and operating conditions.

  16. 77 FR 25366 - Underground Storage Tank Program: Approved State Program for the State of Oregon

    Science.gov (United States)

    2012-04-30

    ... AGENCY 40 CFR Part 282 Underground Storage Tank Program: Approved State Program for the State of Oregon... Agency (EPA) to grant approval to any State to operate its underground storage tank program in the State... statutory and regulatory provisions. This rule codifies the prior approval of Oregon's underground storage...

  17. Helium extraction and nitrogen removal from LNG boil-off gas

    Science.gov (United States)

    Xiong, L.; Peng, N.; Liu, L.; Gong, L.

    2017-02-01

    The helium bearing boil off gas (BOG) from liquid natural gas (LNG) storage tank in LNG plant, which has a helium concentration of about 1%, has attracted the attention in China as a new helium source. As the BOG is usually reused by re-condensing to recover methane, it is likely to cause continuous accumulation of nitrogen in the unit, thus a nitrogen removal process must be integrated. This paper describes a conceptional cryogenic separation system aiming at recovering methane, helium and nitrogen from BOG based on cryogenic distillation and condensation process.

  18. Large-Scale Wireless Temperature Monitoring System for Liquefied Petroleum Gas Storage Tanks

    Directory of Open Access Journals (Sweden)

    Guangwen Fan

    2015-09-01

    Full Text Available Temperature distribution is a critical indicator of the health condition for Liquefied Petroleum Gas (LPG storage tanks. In this paper, we present a large-scale wireless temperature monitoring system to evaluate the safety of LPG storage tanks. The system includes wireless sensors networks, high temperature fiber-optic sensors, and monitoring software. Finally, a case study on real-world LPG storage tanks proves the feasibility of the system. The unique features of wireless transmission, automatic data acquisition and management, local and remote access make the developed system a good alternative for temperature monitoring of LPG storage tanks in practical applications.

  19. Research of Operation Modes of Heat Storage Tank in CHP Plant Using Numerical Simulation

    National Research Council Canada - National Science Library

    Streckiene, Giedre; Miseviciute, Violeta

    2011-01-01

    ... ________________ _________________________________________________________________________________ Volume 6 Re search of Operation Modes of Heat Storage Tank in CHP Plant Using Numerical Simulation Giedre Streckiene 1 , Violeta Miseviciute 2 , 1 - 2 Department...

  20. Operation modes research of liquefied natural gas storages as a part of the ground complexes equipment

    Directory of Open Access Journals (Sweden)

    N. S. Korolev

    2014-01-01

    experimental data. The estimated time before a rollover differs from the experimental value by 2,7%. The relative error of other modelled characteristics of LNG does not exceed 2,5%.Conclusions are drawn on the possibility to use the technique based on the thermodynamics equations of irreversible processes in a binary methane-ethane mixture to forecast working parameters of LNG storages operation as a part of the ground complexes equipment. The techniques to except the rollover mode can be based on keeping a stable LNG composition in the storage and arranging the fuel mixing when performing operations of storage refill and its draining from rocket fuel tanks at start cancellation.

  1. Control system design for robotic underground storage tank inspection systems

    Energy Technology Data Exchange (ETDEWEB)

    Kiebel, G.R.

    1994-09-01

    Control and data acquisition systems for robotic inspection and surveillance systems used in nuclear waste applications must be capable, versatile, and adaptable to changing conditions. The nuclear waste remediation application is dynamic -- requirements change as public policy is constantly re-examined and refocused, and as technology in this area advances. Control and data acquisition systems must adapt to these changing conditions and be able to accommodate future missions, both predictable and unexpected. This paper describes the control and data acquisition system for the Light Duty Utility Arm (LDUA) System that is being developed for remote surveillance and inspection of underground storage tanks at the Hanford Site and other US Department of Energy (DOE) sites. It is a high-performance system which has been designed for future growth. The priority mission at the Hanford site is to retrieve the waste generated by 50 years of production from its present storage and process it for final disposal. The LDUA will help to gather information about the waste and the tanks it is stored in to better plan and execute the cleanup mission.

  2. Underground Storage Tanks, Underground Storage Tank point locations from various sources, Published in 2009, 1:12000 (1in=1000ft) scale, Iredell County GIS.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Underground Storage Tanks dataset, published at 1:12000 (1in=1000ft) scale, was produced all or in part from Published Reports/Deeds information as of 2009. It...

  3. Polymeric hydrogen diffusion barrier, high-pressure storage tank so equipped, method of fabricating a storage tank and method of preventing hydrogen diffusion

    Science.gov (United States)

    Lessing, Paul A [Idaho Falls, ID

    2008-07-22

    An electrochemically active hydrogen diffusion barrier which comprises an anode layer, a cathode layer, and an intermediate electrolyte layer, which is conductive to protons and substantially impermeable to hydrogen. A catalytic metal present in or adjacent to the anode layer catalyzes an electrochemical reaction that converts any hydrogen that diffuses through the electrolyte layer to protons and electrons. The protons and electrons are transported to the cathode layer and reacted to form hydrogen. The hydrogen diffusion barrier is applied to a polymeric substrate used in a storage tank to store hydrogen under high pressure. A storage tank equipped with the electrochemically active hydrogen diffusion barrier, a method of fabricating the storage tank, and a method of preventing hydrogen from diffusing out of a storage tank are also disclosed.

  4. THERMAL STRATIFICATION IN SOLAR DOMESTIC STORAGE TANKS CAUSED BY DRAW-OFFS

    DEFF Research Database (Denmark)

    Jordan, Ulrike; Furbo, Simon

    2003-01-01

    in the storage tank. Furthermore, for theoretical investigations of the flow patterns in the storage tank, calculations were carried out by means of the Computational Fluid Dynamics (CFD) tool Fluent. Based on the experimental and theoretical results, the sizes of fully mixed zones in the bottom part...

  5. Permanent Closure of MFC Biodiesel Underground Storage Tank 99ANL00013

    Energy Technology Data Exchange (ETDEWEB)

    Kerry L. Nisson

    2012-10-01

    This closure package documents the site assessment and permanent closure of the Materials and Fuels Complex biodiesel underground storage tank 99ANL00013 in accordance with the regulatory requirements established in 40 CFR 280.71, “Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.”

  6. MIXING IN DISTRIBUTION SYSTEM STORAGE TANKS: ITS EFFECT ON WATER QUALITY

    Science.gov (United States)

    Nearly all distribution systems in the US include storage tanks and reservoirs. They are the most visible components of a wate distribution system but are generally the least understood in terms of their impact on water quality. Long residence times in storage tanks can have nega...

  7. Melton Valley Storage Tanks Capacity Increase Project, Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    The US Department of Energy (DOE) proposes to construct and maintain additional storage capacity at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee, for liquid low-level radioactive waste (LLLW). New capacity would be provided by a facility partitioned into six individual tank vaults containing one 100,000 gallon LLLW storage tank each. The storage tanks would be located within the existing Melton Valley Storage Tank (MVST) facility. This action would require the extension of a potable water line approximately one mile from the High Flux Isotope Reactor (HFIR) area to the proposed site to provide the necessary potable water for the facility including fire protection. Alternatives considered include no-action, cease generation, storage at other ORR storage facilities, source treatment, pretreatment, and storage at other DOE facilities.

  8. Feasibility report on criticality issues associated with storage of K Basin sludge in tanks farms

    Energy Technology Data Exchange (ETDEWEB)

    Vail, T.S.

    1997-05-29

    This feasibility study provides the technical justification for conclusions about K Basin sludge storage options. The conclusions, solely based on criticality safety considerations, depend on the treatment of the sludge. The two primary conclusions are, (1) untreated sludge must be stored in a critically safe storage tank, and (2) treated sludge (dissolution, precipitation and added neutron absorbers) can be stored in a standard Double Contained Receiver Tank (DCRT) or 241-AW-105 without future restrictions on tank operations from a criticality safety perspective.

  9. Numerical Simulation of Gas Leaking Diffusion from Storage Tank

    Science.gov (United States)

    Zhu, Hongjun; Jing, Jiaqiang

    Over 80 percents of storage tank accidents are caused by gas leaking. Since traditional empirical calculation has great errors, present work aims to study the gas leaking diffusion under different wind conditions by numerical simulation method based on computational fluid dynamics theory. Then gas concentration distribution was obtained to determine the scope of the security zone. The results showed that gas diffused freely along the axis of leaking point without wind, giving rise to large range of hazardous area. However, wind plays the role of migrating and diluting the leaking gas. The larger is the wind speed, the smaller is the damage and the bigger is the security zone. Calculation method and results can provide some reference to establish and implement rescue program for accidents.

  10. Analysis of LNG import terminal release prevention systems

    Energy Technology Data Exchange (ETDEWEB)

    Baker, E G

    1982-04-01

    The release prevention systems of liquefied natural gas (LNG) import terminal were analyzed. A series of potential release scenarios were analyzed to determine the frequency of the release events, the probability these releases are not stopped or isolated by emergency shutdown systems, the estimated release quantities, and the critical components of the system. The two plant areas identified as being most significant with respect to safety are the unloading system and the storage system. Rupture of the main transfer line and gross failure of the storage tanks are the two release scenarios of primary safety interest. Reducing the rate of failure by improved design, better maintenance and testing, or adding redundancy of the critical system components for these plant areas and release scenarios will result in improved safety. Several design alternatives which have the potential to significantly reduce the probability of a large release of LNG occurring at an import terminal are identified. These design alternatives would reduce the probability of a large release of LNG by reducing the expected number of failures which could cause a release or by reducing the magnitude of releases that do occur. All of these alternatives are technically feasible and have been used or considered for use in at least one LNG facility. A more rigorous analysis of the absolute risk of LNG import terminal operation is necessary before the benefits of these design alternatives can be determined. In addition, an economic evaluation of these alternatives must be made so the costs and benefits can be compared. It is concludd that for remotely located facilities many of these alternatives are probably not justified; however, for facilities located in highly populated areas, these alternatives deserve serious consideration.

  11. Research on energy efficiency design index for sea-going LNG carriers

    Science.gov (United States)

    Lin, Yan; Yu, Yanyun; Guan, Guan

    2014-12-01

    This paper describes the characteristics of liquefied natural gas (LNG) carriers briefly. The LNG carrier includes power plant selection, vapor treatment, liquid cargo tank type, etc. Two parameters—fuel substitution rate and recovery of boil of gas (BOG) volume to energy efficiency design index (EEDI) formula are added, and EEDI formula of LNG carriers is established based on ship EEDI formula. Then, based on steam turbine propulsion device of LNG carriers, mathematical models of LNG carriers' reference line value are established in this paper. By verification, the EEDI formula of LNG carriers described in this paper can provide a reference for LNG carrier EEDI calculation and green shipbuilding.

  12. Research on Energy Efficiency Design Index for Sea-going LNG Carriers

    Institute of Scientific and Technical Information of China (English)

    Yan Lin; Yanyun Yu; Guan Guan

    2014-01-01

    This paper describes the characteristics of liquefied natural gas (LNG) carriers briefly. The LNG carrier includes power plant selection, vapor treatment, liquid cargo tank type, etc. Two parameters—fuel substitution rate and recovery of boil of gas (BOG) volume to energy efficiency design index (EEDI) formula are added, and EEDI formula of LNG carriers is established based on ship EEDI formula. Then, based on steam turbine propulsion device of LNG carriers, mathematical models of LNG carriers’ reference line value are established in this paper. By verification, the EEDI formula of LNG carriers described in this paper can provide a reference for LNG carrier EEDI calculation and green shipbuilding.

  13. LNG Cold Energy Utilization of Floating Storage and Regasification Unit%浮式储存再气化装置的LNG冷能利用

    Institute of Scientific and Technical Information of China (English)

    黄刘松; 宋炜; 刘涛

    2016-01-01

    Liquefied Natural Gas (LNG) will become one of the main energy sources for mankind in the 21st century. This paper systematically introduces the floating LNG receiving terminals in terms of concept, categorization, characteristics and system formation, etc., and summarizes their differences and deficiencies compared with LNG receiving terminals on land. Meanwhile, this paper also elaborates the LNG cold energy as well as its evaluation factors and utilization methods, and compares the utilization method of part of the LNG cold energy with conventional electrical consumption method. On this basis, the feasibilities of low temperature power generation, air separation, light hydrocarbon recovery, sea water desalination, liquefied CO2 and dry ice production, low temperature smashing, frozen and refrigeration, natural gas re-liquefaction, butyl rubber production, gas turbine air inlet and outlet cooling, application of offshore LNG cold energy utilization industrial park on FSRU (Floating Storage and Regasification Unit) are analyzed from aspects of initial investment, equipment size, level of commercialization, market potential, environmental protection, etc. to finally come to the conclusion that proper FSRU cold energy utilization method may include cold energy power generation, air separation, natural gas re-liquefaction, gas turbine air inlet and outlet cooling.%液化天然气(Liquefied Natural Gas, LNG)将成为人类在21世纪的主要能源之一。对浮式LNG接收终端从概念、分类、特点、系统组成等方面进行了较系统的介绍,总结了与陆地 LNG 接收站的不同特点及其不足之处。同时阐述了LNG冷能、LNG冷能的评价因素及利用方式,并将部分LNG冷能的利用方式与常规方式的电力消耗进行对比。在此基础上,从初投资、装置大小、商业化程度、市场潜力、环境保护等角度对低温发电、空气分离、轻烃回收、海水淡化、液态CO2及干冰制备、

  14. Closure Report for Underground Storage Tank 2310-U at the Pine Ridge West Repeater Station

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This document represents the Closure Report for Underground Storage Tank (UST) 2310-U at the Pine Ridge West Repeater Station, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Tank 2310-U was a 200-gal gasoline UST which serviced the emergency generator at the Repeater Station. The tank was situated in a shallow tank bay adjacent to the Repeater Station along the crest of Pine Ridge. The tank failed a tightness test in October 1989 and was removed in November 1989. The purpose of this report is to document completion of soil corrective action, present supporting analytical data, and request closure for this site.

  15. Particle behaviour consideration to maximize the settling capacity of rainwater storage tanks.

    Science.gov (United States)

    Han, M Y; Mun, J S

    2007-01-01

    Design of a rainwater storage tank is mostly based on the mass balance of rainwater with respect to the tank, considering aspects such as rainfall runoff, water usage and overflow. So far, however, little information is available on the quality aspects of the stored rainwater, such as the behavior of particles, the effect of retention time of the water in the tank and possible influences of system configuration on water quality in the storage tank. In this study, we showed that the performance of rainwater storage tanks could be maximized by recognizing the importance of water quality improvement by sedimentation and the importance of the system configuration within the tank, as well as the efficient collection of runoff. The efficiency of removal of the particles was increased by there being a considerable distance between the inlet and the outlet in the rainwater storage tank. Furthermore, it is recommended that the effective water depth in a rainwater tank be designed to be more than 3 m and that the rainwater be drawn from as close to the water surface as possible by using a floating suction device. An operation method that increases the retention time by stopping rainwater supply when the turbidity of rainwater runoff is high will ensure low turbidity in the rainwater collected from the tank.

  16. Technical Assessment of Compressed Hydrogen Storage Tank Systems for Automotive Applications

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Thanh [Argonne National Lab. (ANL), Argonne, IL (United States); Ahluwalia, Rajesh [Argonne National Lab. (ANL), Argonne, IL (United States); Peng, J. -K [Argonne National Lab. (ANL), Argonne, IL (United States); Kromer, Matt [TIAX LLC, Lexington, MA (United States); Lasher, Stephen [TIAX LLC, Lexington, MA (United States); McKenney, Kurtis [TIAX LLC, Lexington, MA (United States); Law, Karen [TIAX LLC, Lexington, MA (United States); Sinha, Jayanti [TIAX LLC, Lexington, MA (United States)

    2010-09-01

    This technical report describes DOE's assessment of the performance and cost of compressed hydrogen storage tank systems for automotive applications. The on-board performance (by Argonne National Lab) and high-volume manufacturing cost (by TIAX LLC) were estimated for compressed hydrogen storage tanks. The results were compared to DOE's 2010, 2015, and ultimate full fleet hydrogen storage targets. The Well-to-Tank (WTT) efficiency as well as the off-board performance and cost of delivering compressed hydrogen were also documented in the report.

  17. Thermal Stratification in Small Solar Domestic Storage Tanks caused by Draw-offs

    DEFF Research Database (Denmark)

    Jordan, Ulrike; Furbo, Simon

    2005-01-01

    As shown in many research studies in the past, the thermal stratification of the tank caused by draw-offs has a high impact on the performance of a Solar Domestic Hot Water (SDHW) system. Nevertheless, in most tank models for system simulations the influence of the draw-off pattern on the mixing...... behaviour is not taken into account sufficiently. Two typical Danish domestic water storage tanks, each with a volume of about 150 l, were investigated. In both tanks the inlet pipes are placed at the bottom and hot water is drawn from the upper part of tank. Above the inlet pipes, differently shaped plates...... are placed in order to reduce the mixing of the incoming cold water with the warmer storage water. To measure the thermal stratification thermocouples were placed in a vertical glass tube inside the tank. Measurements were carried out with different draw-off volumes, flow rates, and initial temperatures...

  18. A STUDY OF CORROSION AND STRESS CORROSION CRACKING OF CARBON STEEL NUCLEAR WASTE STORAGE TANKS

    Energy Technology Data Exchange (ETDEWEB)

    BOOMER, K.D.

    2007-08-21

    The Hanford reservation Tank Farms in Washington State has 177 underground storage tanks that contain approximately 50 million gallons of liquid legacy radioactive waste from cold war plutonium production. These tanks will continue to store waste until it is treated and disposed. These nuclear wastes were converted to highly alkaline pH wastes to protect the carbon steel storage tanks from corrosion. However, the carbon steel is still susceptible to localized corrosion and stress corrosion cracking. The waste chemistry varies from tank to tank, and contains various combinations of hydroxide, nitrate, nitrite, chloride, carbonate, aluminate and other species. The effect of each of these species and any synergistic effects on localized corrosion and stress corrosion cracking of carbon steel have been investigated with electrochemical polarization, slow strain rate, and crack growth rate testing. The effect of solution chemistry, pH, temperature and applied potential are all considered and their role in the corrosion behavior will be discussed.

  19. Seismic Fragility Analysis of a Degraded Condensate Storage Tank

    Energy Technology Data Exchange (ETDEWEB)

    Nie, J.; Braverman, J.; Hofmayer, C.; Choun, Y-S.; Kim, M.K.; Choi, I-K.

    2011-05-16

    The Korea Atomic Energy Research Institute (KAERI) and Brookhaven National Laboratory are conducting a collaborative research project to develop seismic capability evaluation technology for degraded structures and components in nuclear power plants (NPPs). One of the goals of this collaboration endeavor is to develop seismic fragility analysis methods that consider the potential effects of age-related degradation of structures, systems, and components (SSCs). The essential part of this collaboration is aimed at achieving a better understanding of the effects of aging on the performance of SSCs and ultimately on the safety of NPPs. A recent search of the degradation occurrences of structures and passive components (SPCs) showed that the rate of aging related degradation in NPPs was not significantly large but increasing, as the plants get older. The slow but increasing rate of degradation of SPCs can potentially affect the safety of the older plants and become an important factor in decision making in the current trend of extending the operating license period of the plants (e.g., in the U.S. from 40 years to 60 years, and even potentially to 80 years). The condition and performance of major aged NPP structures such as the containment contributes to the life span of a plant. A frequent misconception of such low degradation rate of SPCs is that such degradation may not pose significant risk to plant safety. However, under low probability high consequence initiating events, such as large earthquakes, SPCs that have slowly degraded over many years could potentially affect plant safety and these effects need to be better understood. As part of the KAERI-BNL collaboration, a condensate storage tank (CST) was analyzed to estimate its seismic fragility capacities under various postulated degradation scenarios. CSTs were shown to have a significant impact on the seismic core damage frequency of a nuclear power plant. The seismic fragility capacity of the CST was developed

  20. A storage gas tank is moved to a pallet in the O&C

    Science.gov (United States)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- Workers in the Operations and Checkout Building stand by while one of four gas tanks is moved toward the Spacelab Logistics Double Pallet. Part of the STS-104 payload, the storage tanks two gaseous oxygen and two gaseous nitrogen -- comprise the high pressure gas assembly that will be attached to the Joint Airlock Module during two spacewalks. The tanks will support future spacewalk operations from the Station and augment the Service Module gas resupply system.

  1. 76 FR 46798 - Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction

    Science.gov (United States)

    2011-08-03

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction AGENCY... compliance with the Federal compatibility requirement for UST systems storing gasoline greater than...

  2. LEAKING UNDERGROUND STORAGE TANKS: REMEDIATION WITH EMPHASIS ON IN SITU BIORESTORATION

    Science.gov (United States)

    The current literature indicates that in situ biorestoration has great potential for remediation of aquifers contaminated by leaking underground storage tanks. In situ aquifer restoration involves the enhancement of the indigenous microflora to degrade subsurface pollutants. The ...

  3. Indian Country Leaking Underground Storage Tank (LUST) Points, Region 9, 2016, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains point features that represent Leaking Underground Storage Tanks in US EPA Region 9 Indian Country. This dataset contains facility name and...

  4. Numerical simulation on heat transfer characteristics of the storage tank for concentrating solar power plant

    Directory of Open Access Journals (Sweden)

    Qianjun Mao

    2016-06-01

    Full Text Available Concentrating solar power plant coupling with energy storage is a new and emerging technology, which can solve two issues, that is, low flux density and intermittent of solar energy. Heat transfer characteristics of the storage tank in this system have a key effect on the system’s efficiency and cost. In this article, the heat transfer performance of a phase change thermal storage tank has been proposed, and the temperature distribution and liquid fraction of phase change material in the tank has numerically been investigated. The results show that the temperature increases with the increasing charge time. The results also show that there is a phase change process at the charge time of 200 min, and no phase change for the charge time of 250 and 300 min. The results of this article can provide a reference for future design and optimal operation of the storage tank in concentrating solar power plant.

  5. Small-Scale Metal Tanks for High Pressure Storage of Fluids

    Science.gov (United States)

    London, Adam (Inventor)

    2016-01-01

    Small scale metal tanks for high-pressure storage of fluids having tank factors of more than 5000 meters and volumes of ten cubic inches or less featuring arrays of interconnected internal chambers having at least inner walls thinner than gage limitations allow. The chambers may be arranged as multiple internal independent vessels. Walls of chambers that are also portions of external tank walls may be arcuate on the internal and/or external surfaces, including domed. The tanks may be shaped adaptively and/or conformally to an application, including, for example, having one or more flat outer walls and/or having an annular shape. The tanks may have dual-purpose inlet/outlet conduits of may have separate inlet and outlet conduits. The tanks are made by fusion bonding etched metal foil layers patterned from slices of a CAD model of the tank. The fusion bonded foil stack may be further machined.

  6. Concept for a LNG Gas Handling System for a Dual Fuel Engine

    Directory of Open Access Journals (Sweden)

    Michael Rachow

    2017-09-01

    Full Text Available Nowadays, ships are using LNG as main engine fuel because based on the facts that LNG has no sulphur content, and its combustion process, LNG produces low NOx content compared to heavy fuel oil and marine diesel oil. LNG is not only produces low gas emission, but may have economic advantages. In the engine laboratory of maritime studies department in Warnemunde, Germany, there is a diesel engine type MAN 6L23/30 A, where the mode operation of these engine would be changed to dual fuel engine mode operation. Therefore, in this thesis, the use dual fuel engine will be compared where it will utilize natural gas and marine diesel oil and select the required components for fuel gas supply system. By conducting the process calculation, engine MAN 6L23/30 A requires the capacity natural gas of 12.908  for 5 days at full load. A concept for LNG supply system would be arranged from storage tank until engine manifold. Germanischer Lloyd and Project Guide of dual fuel engine will be used as a guidelines to develop an optimal design and arrangement which comply with the regulation.

  7. Risk assessment of Kermanshah gas storage tanks by energy trace and barrier analysis (2014)

    OpenAIRE

    M. Ghanbari Kakavandi; F. Rajati; H. Ashtarian; SY. Hosseini

    2016-01-01

    Background: Despite the cost and millions loss of life due to industrial accidents, often are preventable through risk assessment methods and control measures. Objective: To assess the safety of gas storage tanks in Kermanshah oil refinery by Energy Trace and Barrier Analysis (ETBA). Methods: This case-descriptive study was conducted in gas storage tanks of Kermanshah oil refinery. Energy checklist was used for identification of energy types. Energy flows were tracked and then, manageme...

  8. Permeability of Flexible Materials Used in Fuel Storage Tanks. Part 1. General Review

    Science.gov (United States)

    1983-08-01

    459 PERMEABILITY OF FLEXIBLE MATERIALS USED IN FUEL STORAGE TANKS: PART 1 - GENERAL REVIEW B.C. Ennis- THE UNITED STATES NATIONAL TECHNICAL INFMATION... GENERAL REVIEW Accession For NTIS T&i Ju £ , ,, L f T B.C. Ennis * .... . . ABSTRACT I A review of the transport of hydrocarbon fuels through composite...PERMEABILITY OF FLEXIBLE MATERIALS USED IN FUEL STORAGE TANKS% ’I PART 1 - GENERAL REVIEW MT40R(S) COF"ATE AUTHOR Materlals Research Laboratories• !ENNIS

  9. Numerical Investigation of Effective Heat Conductivity of Fluid in Charging Process of Thermal Storage Tank

    OpenAIRE

    Taheri, H.; Schmidt, F. P.; Gabi, M.

    2015-01-01

    This paper presents a numerical case study of heat transfer mechanisms during the charging process of a stratified thermal storage tank applied in a specific adsorption heat pump cycle. The effective thermal conductivity of the heat transfer fluid during the charging process is analyzed through CFD simulations using Unsteady Reynolds-averaged Navier-Stokes equations (URANS). The aim of the study is to provide an equivalent thermal conductivity for a one-dimensional storage tank model to be us...

  10. Storage tank materials for biodiesel blends; the analysis of fuel property changes

    Directory of Open Access Journals (Sweden)

    Nurul Komariah Leily

    2017-01-01

    Full Text Available Fuel stability is one of major problem in biodiesel application. Some of the physical properties of biodiesel are commonly changed during storage. The change in physico-chemical properties is strongly correlated to the stability of the fuel. This study is objected to observe the potential materials for biodiesel storage. The test was conducted in three kinds of tank materials, such as glass, HDPE, and stainless steel. The fuel properties are monitored in 12 weeks, while the sample was analyzed every week. Biodiesel used is palm oil based. The storage tanks were placed in a confined indoor space with range of temperature 27–34 °C. The relative humidity and sunshine duration on the location was also evaluated. The observed properties of the fuel blends were density, viscosity and water content. During 12 weeks of storage, the average density of B20 was changed very slightly in all tanks, while the viscosity was tend to increase sharply, especially in polimerics tank. Water content of B20 was increased by the increase of storage time especially in HDPE tank. In short period of storage, the biodiesel blends is found more stable in glass tank due to its versatility to prohibit oxidation, degradation, and its chemical resistance.

  11. 40 CFR Table 21 to Subpart G of... - Average Storage Temperature (Ts) as a Function of Tank Paint Color

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Average Storage Temperature (Ts) as a Function of Tank Paint Color 21 Table 21 to Subpart G of Part 63 Protection of Environment ENVIRONMENTAL... (Ts) as a Function of Tank Paint Color Tank Color Average Storage Temperature (Ts) White TA a =...

  12. Opportunistic pathogens relative to physicochemical factors in water storage tanks.

    Science.gov (United States)

    Al-Bahry, S N; Elshafie, A E; Victor, R; Mahmoud, I Y; Al-Hinai, J A

    2011-06-01

    Household water in Oman, as well as in other countries in the region, is stored in tanks placed on house roofs that can be subjected to physicochemical factors which can promote microbial growth, including pathogens and opportunistic pathogens which pose health risks. Water samples were collected from 30 houses in a heavily populated suburb of Muscat. The tanks used were either glass reinforced plastic (GRP), polyethylene or galvanised iron (GI). Heterotrophic bacteria, coliforms, faecal coliforms and iron sulphur bacteria varied significantly in the three tanks. Yeast and mould count showed significant variations. Isolation of Aeromonas spp., fluorogenic and pathogenic Pseudomonas, Pasteurella, Salmonella, Serratia and Tatumella, and Yersinia and Legionella in biofilms varied in the three tanks. The fungi isolates in the three tanks were Penicillium, Cladosporium and Aspergillus. Nephelometric turbidity unit, threshold odour number and free chlorine varied significantly in the three tanks. True colour unit values did not show a significant difference; however, GRP tanks had algae, autotrophic and pigmented microorganisms. In addition, GI tanks had sediments and corrosion. The results of this investigation are important to evaluate the status of the present household water tanks in countries with high annual temperatures, which may affect public health.

  13. Smart solar tanks - Heat storage of the future?

    DEFF Research Database (Denmark)

    Furbo, Simon; Shah, Louise Jivan

    1997-01-01

    can be large and in periods with a small hot water demand the volume can be small. For instance, the energy supply system can be controlled on measurements of the energy content of the tank during all hours of the week and based on a required hot water consumption and consumption pattern which can...... be selected by the owner of the system. Preliminary tests of a 175 l smart solar tank have been carried out. Finally, theoretical calculations of the yearly thermal performances of small SDHW-systems based on standard tanks and on a smart solar tank have been carried out. Based on the investigations...

  14. Effect of hot-water consumption on temperature distribution in a horizontal solar water storage tank

    Energy Technology Data Exchange (ETDEWEB)

    Helwa, N.H.; El-Ghetany, H.H. [National Research Center, Cairo (Egypt). Dept. of Solar Energy; Mobarak, A.M.; El-Sallak, M.S. [Cairo Univ. (Egypt). Dept. of Mechanical Engineering

    1995-12-31

    This experimental investigation assesses the behaviour of a solar water heater provided with a liquid heat exchanger in a horizontal storage tank. The factors that affect the stratification inside the storage tank are considered. The performance of the system is studied in the light of the daily consumption of hot water of an Egyptian family. The results obtained show that in the places where it is necessary to use a horizontal tank it must be supplied with an auxiliary electric heater to meet the required load at the required temperature, especially in winter. (author)

  15. South Tank Farm underground storage tank inspection using the topographical mapping system for radiological and hazardous environments

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, G.A.; Burks, B.L.; Hoesen, S.D. van

    1997-07-01

    During the winter of 1997 the Topographical Mapping System (TMS) for hazardous and radiological environments and the Interactive Computer-Enhanced Remote-Viewing System (ICERVS) were used to perform wall inspections on underground storage tanks (USTs) W5 and W6 of the South Tank Farm (STF) at Oak Ridge National Laboratory (ORNL). The TMS was designed for deployment in the USTs at the Hanford Site. Because of its modular design, the TMS was also deployable in the USTs at ORNL. The USTs at ORNL were built in the 1940s and have been used to store radioactive waste during the past 50 years. The tanks are constructed with an inner layer of Gunite{trademark} that has been spalling, leaving sections of the inner wall exposed. Attempts to quantify the depths of the spalling with video inspection have proven unsuccessful. The TMS surface-mapping campaign in the STF was initiated to determine the depths of cracks, crevices, and/or holes in the tank walls and to identify possible structural instabilities in the tanks. The development of the TMS and the ICERVS was initiated by DOE for the purpose of characterization and remediation of USTs at DOE sites across the country. DOE required a three-dimensional, topographical mapping system suitable for use in hazardous and radiological environments. The intended application is mapping the interiors of USTs as part of DOE`s waste characterization and remediation efforts, to obtain both baseline data on the content of the storage tank interiors and changes in the tank contents and levels brought about by waste remediation steps. Initially targeted for deployment at the Hanford Site, the TMS has been designed to be a self-contained, compact, and reconfigurable system that is capable of providing rapid variable-resolution mapping information in poorly characterized workspaces with a minimum of operator intervention.

  16. Operation Performance of Central Solar Heating System with Seasonal Storage Water Tank in Harbin

    Institute of Scientific and Technical Information of China (English)

    YE Ling; JIANG Yi-qiang; YAO Yang; ZHANG Shi-cong

    2009-01-01

    This paper presented a preliminary research on the central solar heating system with seasonal stor-age(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in the central solar heating system was firstly developed based on energy conservation.This was fol-lowed by the simulation of the CSHSSS used in a two-floor villa in Harbin,and analysis of the impacts on storage water temperature of tank volume,solar collector area,tank burial depth,insulation thickness around the tank,etc.The results show there is a relatively economical tank volume to optimize the system efficiency,which de-creases with increasing tank volume at the constant collector area,and increases with increasing collector area at the constant tank volume.Furthermore,the insulation thickness has obvious effect on avoiding heat loss,while the tank burial depth doesn't.In addition-the relationship between the solar collector efficiency and storage wa-ter temperature is also obtained,it decreases quickly with increasing storing water temperature,and then in-creases slowly after starting space heating system.These may be helpful for relevant design and optimization in cold climates in China and all over the world.

  17. Acquisition and data analysis of storage tank bottoms for life prediction

    Energy Technology Data Exchange (ETDEWEB)

    Aparecido da Silva, M. [Petroquimica Uniao, Sao Paulo (Brazil); Tus, R. [Rosen Europe, Oldenzaal (Netherlands)

    2006-07-01

    Several techniques can be used to develop important life prediction information regarding structural conditions of storage tank bottoms. However, there is a limited availability of test that can be obtained from in service structural components. The reasons for applying life prediction methodology to aging storage tanks: more stringent safety and environment regulations, avoid costly forced outages, the limited availability of construction sites for new tanks, the expense of constructing, etc. The cause for applying life prediction methodology in aging tanks is material degradation. Nondestructive evaluation technique for characterizing and sizing important mechanical conditions in storage tank bottoms have been developed by the Company Rosen Inspection Technologies. The Tank Bottom Inspection Tool (TBIT) is capable to detect, data collecting and sizing in real time oriented flaws defects as well as metal loss features with length of 03 mm and depth of 50%. The technique based in high resolution MFL (Magnetic Flux Leakage) was applied in a petrochemical storage tank and compared with visual and dimensional analysis. The results show accurate information for predicting life. (orig.)

  18. The electrostatic properties of Fiber-Reinforced-Plastics double wall underground storage gasoline tanks

    Science.gov (United States)

    Li, Yipeng; Liu, Quanzhen; Meng, He; Sun, Lifu; Zhang, Yunpeng

    2013-03-01

    At present Fiber Reinforced Plastics (FRP) double wall underground storage gasoline tanks are wildly used. An FRP product with a resistance of more than 1011 Ω is a static non-conductor, so it is difficult for the static electricity in the FRP product to decay into the earth. In this paper an experimental system was built to simulate an automobile gasoline filling station. Some electrostatic parameters of the gasoline, including volume charge density, were tested when gasoline was unloaded into a FRP double wall underground storage tank. Measurements were taken to make sure the volume charge density in the oil-outlet was similar to the volume charge density in the tank. In most cases the volume charge density of the gasoline was more than 22.7 μC m-3, which is likely to cause electrostatic discharge in FRP double wall underground storage gasoline tanks. On the other hand, it would be hard to ignite the vapor by electrostatic discharge since the vapor pressure in the tanks is over the explosion limit. But when the tank is repaired or re-used, the operators must pay attention to the static electricity and some measurements should be taken to avoid electrostatic accident. Besides the relaxation time of charge in the FRP double wall gasoline storage tanks should be longer.

  19. Regional scale analysis for the design of storage tanks for domestic rainwater harvesting systems.

    Science.gov (United States)

    Campisano, A; Modica, C

    2012-01-01

    A regional scale analysis for the design of storage tanks for domestic rain water harvesting systems is presented. The analysis is based on the daily water balance simulation of the storage tank by the yield-after-spillage algorithm as tank release rule. Water balances are applied to 17 rainfall gauging stations in Sicily (Italy). Compared with literature existing methods, a novel dimensionless parameter is proposed to better describe the intra-annual character of the rainfall patterns. As a result, easy-to-use regional regressive models to evaluate the water saving performance and the overflow discharges from the tank are provided along with a stepwise procedure for practical application. The regional models demonstrate good fits between model predictions and simulated values of both water savings and overflows from the tank.

  20. 75 FR 70350 - Liberty Natural Gas LLC, Liberty Liquefied Natural Gas (LNG) Deepwater Port License Application

    Science.gov (United States)

    2010-11-17

    ... Maritime Administration Liberty Natural Gas LLC, Liberty Liquefied Natural Gas (LNG) Deepwater Port License... receive and transfer natural gas from purpose-build LNG regasification vessels (LNGRVs) with a total cargo tank capacity of approximately 145,000 m\\3\\. The vessels would be equipped to vaporize LNG cargo...

  1. Experimental Investigation of Jet-Induced Mixing of a Large Liquid Hydrogen Storage Tank

    Science.gov (United States)

    Lin, C. S.; Hasan, M. M.; Vandresar, N. T.

    1994-01-01

    Experiments have been conducted to investigate the effect of fluid mixing on the depressurization of a large liquid hydrogen storage tank. The test tank is approximately ellipsoidal, having a volume of 4.89 m(exp 3) and an average wall heat flux of 4.2 W/m(exp 2) due to external heat input. A mixer unit was installed near the bottom of the tank to generate an upward directed axial jet flow normal to the liquid-vapor interface. Mixing tests were initiated after achieving thermally stratified conditions in the tank either by the introduction of hydrogen gas into the tank or by self-pressurization due to ambient heat leak through the tank wall. The subcooled liquid jet directed towards the liquid-vapor interface by the mixer induced vapor condensation and caused a reduction in tank pressure. Tests were conducted at two jet submergence depths for jet Reynolds numbers from 80,000 to 495,000 and Richardson numbers from 0.014 to 0.52. Results show that the rate of tank pressure change is controlled by the competing effects of subcooled jet flow and the free convection boundary layer flow due to external tank wall heating. It is shown that existing correlations for mixing time and vapor condensation rate based on small scale tanks may not be applicable to large scale liquid hydrogen systems.

  2. A numerical study on the discharging performance of a packing module in a thermal storage tank

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Tae; Chung, Jae Dong [Dept. of Mechanical Engineering, Sejong University, Seoul (Korea, Republic of); Park Hyoung Joon [Dept of.evelopment Center, Janghan Engineers. INC., Dangjin (Korea, Republic of)

    2015-07-15

    In this study, a numerical analysis on the discharging performance of a thermal storage tank completely filled with packing modules is investigated. The enthalpy-porosity method is adopted to analyze phase change phenomenon. Using this method, the melting process of a packing module in the thermal storage tank was studied as the HTF (heat transfer fluid) flows down from the top of the tank at the discharging mode. There are some design factors such as the module arrangement and the number of modules, but this study focuses on the effects of varying the flow rate of the HTF on the outlet temperature of the HTF, molten fraction, and thermal storage density. As the flow rate increases, the outlet temperature of the HTF gets higher and the total melting time of the PCM decreases. Additionally, the thermal storage density is increased so that it reaches about 93% for the desired value.

  3. PENGAMBILAN KEPUTUSAN KRITERIA JAMAK (MCDM UNTUK PEMILIHAN LOKASI FLOATING STORAGE AND REGASIFICATION UNIT (FSRU: STUDI KASUS SUPLAI LNG DARI LADANG TANGGUH KE BALI

    Directory of Open Access Journals (Sweden)

    Ketut Buda Artana

    2008-01-01

    Full Text Available This paper presents a case study in selecting the best location for a Floating Storage and Regasification Unit (FSRU in Bali. FSRU is an alternative to replace a conventional shore LNG terminal. The selection involves several criteria/attributes that can be grouped into two general criteria, namely qualitative and quantitative criteria. Multiple Criteria Decision Making (MCDM approach is utilized to solve the selection problem, considering the capability of this method in solving multi-criteria problem with mutual conflict. Qualitative criteria are evaluated using AHP method to calculate weight of each criterion. Moreover, decision matrix algorithm is then utilized to convert preference of stakeholders into, consecutively, probability assignment, total probability assignment and preference degree eventually. Quantitative criteria are also converted into preference degree and entropy method is used to rank the alternatives. Selected location would be the alternative having the highest entropy. Four alternatives are under consideration. Those alternatives are Benoa, Celukan Bawang, Pemaron and Gilimanuk. This research found that Celukan Bawang is the best location for the FSRU. Abstract in Bahasa Indonesia: Paper ini menyajikan pemilihan lokasi Floating Storage and Regasification Unit (FSRU untuk proses distribusi LNG dari Ladang Tangguh ke Bali. FSRU merupakan alternatif pengganti LNG receiving terminal di darat. Pemilihan lokasi ini melibatkan kriteria kualitatif dan kuantitatif dan metode Multiple Criteria Decision Making (MCDM digunakan untuk melakukan pemilihan mengingat metode ini dapat memberi solusi tepat saat mutual conflict terjadi pada beberapa kriteria pemilihan. Penilaian terhadap beberapa alternatif didasarkan atas nilai masing-masing kriteria yang diperoleh dari kuisioner terhadap beberapa stakeholders. Untuk kriteria kualitatif dicari relative weight dengan menggunakan metode Analitik Hierarki Proses (AHP. Nilai relative weight ini

  4. Safe interim storage of Hanford tank wastes, draft environmental impact statement, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This Draft EIS is prepared pursuant to the National Environmental Policy Act (NEPA) and the Washington State Environmental Policy Act (SEPA). DOE and Ecology have identified the need to resolve near-term tank safety issues associated with Watchlist tanks as identified pursuant to Public Law (P.L.) 101-510, Section 3137, ``Safety Measures for Waste Tanks at Hanford Nuclear Reservation,`` of the National Defense Authorization Act for Fiscal Year 1991, while continuing to provide safe storage for other Hanford wastes. This would be an interim action pending other actions that could be taken to convert waste to a more stable form based on decisions resulting from the Tank Waste Remediation System (TWRS) EIS. The purpose for this action is to resolve safety issues concerning the generation of unacceptable levels of hydrogen in two Watchlist tanks, 101-SY and 103-SY. Retrieving waste in dilute form from Tanks 101-SY and 103-SY, hydrogen-generating Watchlist double shell tanks (DSTs) in the 200 West Area, and storage in new tanks is the preferred alternative for resolution of the hydrogen safety issues.

  5. Rainwater Harvesting in South India: Understanding Water Storage and Release Dynamics at Tank and Catchment Scales

    Science.gov (United States)

    Basu, N. B.; Van Meter, K. J.; Mclaughlin, D. L.; Steiff, M.

    2015-12-01

    Rainwater harvesting, the small-scale collection and storage of runoff for irrigated agriculture, is recognized as a sustainable strategy for ensuring food security, especially in monsoonal landscapes in the developing world. In south India, these strategies have been used for millennia to mitigate problems of water scarcity. However, in the past 100 years many traditional rainwater harvesting systems have fallen into disrepair due to increasing dependence on groundwater. With elevated declines in groundwater resources, there is increased effort at the state and national levels to revive older systems. Critical to the success of such efforts is an improved understanding of how these ancient water-provisioning systems function in contemporary landscapes with extensive groundwater pumping and shifted climatic regimes. Knowledge is especially lacking regarding the water-exchange dynamics of these rainwater harvesting "tanks" at tank and catchment scales, and how these exchanges regulate tank performance and catchment water balances. Here, we use fine-scale water level variations to quantify daily fluxes of groundwater, evapotranspiration, and sluice outflows in four tanks over the 2013 northeast monsoon season in a tank cascade that covers a catchment area of 28.2 km2. Our results indicate a distinct spatial pattern in groundwater-exchange dynamics, with the frequency and magnitude of groundwater inflow events (as opposed to outflow) increasing down the cascade of tanks. The presence of tanks in the landscape dramatically alters the catchment water balance, with catchment-scale runoff:rainfall ratios decreasing from 0.29 without tanks to 0.04 - 0.09 with tanks. Recharge:rainfall ratios increase in the presence of tanks, from ~0.17 in catchments without tanks to ~ 0.26 in catchments with tanks. Finally, our results demonstrate how more efficient management of sluice outflows can lead to the tanks meeting a higher fraction of crop water requirements.

  6. Effect of tank diameter on thermal behavior of gasoline and diesel storage tanks fires.

    Science.gov (United States)

    Leite, Ricardo Machado; Centeno, Felipe Roman

    2017-08-24

    Studies on fire behavior are extremely important as they contribute in a firefighting situation or even to avoid such hazard. Experimental studies of fire in real scale are unfeasible, implying that reduced-scale experiments must be performed, and results extrapolated to the range of interest. This research aims to experimentally study the fire behavior in tanks of 0.04m, 0.20m, 0.40m, 0.80m and 4.28m diameter, burning regular gasoline or diesel oil S-500. The following parameters were here obtained: burning rates, burning velocities, heat release rates, flame heights, and temperature distributions adjacent to the tank. Such parameters were obtained for each tank diameter with the purpose of correlating the results and understanding the relationship of each parameter for the different geometrical scale of the tanks. Asymptotic results for larger tanks were found as (regular gasoline and diesel oil S-500, respectively): burning rates 0.050kg/(m(2)s) and 0.031kg/(m(2)s), burning velocities 4.0mm/min and 2.5mm/min, heat release rates per unit area 2200kW/m(2) and 1500kW/m(2), normalized averaged flame heights (Hi/D, where Hi is the average flame height, D is the tank diameter) 0.9 and 0.8. Maximum temperatures for gasoline pools were higher than for diesel oil pools, and temperature gradients close to the tanks were also higher for the former fuel. The behavior of the maximum temperature was correlated as a function of the tank diameter, the heat release rate of each fuel and the dimensionless distance from the tank. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Energy system investment model incorporating heat pumps with thermal storage in buildings and buffer tanks

    DEFF Research Database (Denmark)

    Hedegaard, Karsten; Balyk, Olexandr

    2013-01-01

    options: passive heat storage in the building structure via radiator heating, active heat storage in concrete floors via floor heating, and use of thermal storage tanks for space heating and hot water. It is shown that the model is well qualified for analysing possibilities and system benefits...... be taken into account. In this study, we present a model that facilitates analysing individual heat pumps and complementing heat storages in integration with the energy system, while optimising both investments and operation. The model incorporates thermal building dynamics and covers various heat storage...

  8. On the Behavior of Different PCMs in a Hot Water Storage Tank against Thermal Demands

    Directory of Open Access Journals (Sweden)

    Jacobo Porteiro

    2016-03-01

    Full Text Available Advantages, such as thermal storage improvement, are found when using PCMs (Phase Change Materials in storage tanks. The inclusion of three different types of materials in a 60 l test tank is studied. Two test methodologies were developed, and four tests were performed following each methodology. A thermal analysis is performed to check the thermal properties of each PCM. The distributions of the water temperatures inside the test tanks are evaluated by installing four Pt-100 sensors at different heights. A temperature recovery is observed after exposing the test tank to an energy demand. An energetic analysis that takes into account the energy due to the water temperature, the energy due to the PCM and the thermal loss to the ambient environment is also presented. The percentage of each PCM that remains in the liquid state after the energy demand is obtained.

  9. Decision and systems analysis for underground storage tank waste retrieval systems and tank waste remediation system

    Energy Technology Data Exchange (ETDEWEB)

    Bitz, D.A. [Independent Consultant, Kirkland, WA (United States); Berry, D.L. [Sandia National Labs., Albuquerque, NM (United States); Jardine, L.J. [Lawrence Livermore National Lab., CA (United States)

    1994-03-01

    Hanford`s underground tanks (USTs) pose one of the most challenging hazardous and radioactive waste problems for the Department of Energy (DOE). Numerous schemes have been proposed for removing the waste from the USTs, but the technology options for doing this are largely unproven. To help assess the options, an Independent Review Group (IRG) was established to conduct a broad review of retrieval systems and the tank waste remediation system. The IRG consisted of the authors of this report.

  10. Discharging Part of LNG Liquid Cargo Handling Simulator

    Directory of Open Access Journals (Sweden)

    Zhen-Zhou Yang

    2013-09-01

    Full Text Available With the development of the national economy, it is important to develop LNG (Liquefied Natural Gas liquid cargo handling simulator. In this paper, the discharging part of Liquid Cargo Handling Simulator of LNG Carriers is developed by Visual Basic. The system includes 5 major forms and 3 mathematical models such as cargo pump model, the pressure and temperature model of the LNG vapour in the cargo tank and the liquid level model. The system can complete the unloading task. The system has become a preliminary model of LNG liquid cargo handlings simulator training.

  11. Increase the level of environmental safety for mechanical ventilation of light-oil storage tanks

    OpenAIRE

    Гарбуз, Сергей Викторович

    2015-01-01

    This paper evaluated the environmental risk of degassing light oil-storage tank, by quantifying emissions of hydrocarbon vapors in the air. To determine the basic parameters of the degassing tank that is carried out by mechanical ventilation, it has been created test bench geometrically similar to RVS-5000. Based on theoretical and experimental data, it is calculated the concentration of harmful substances (hydrocarbons) in the air for degassing method using in Ukraine, at all stages.Based on...

  12. Thermal Performance Comparison of Glass Microsphere and Perlite Insulation Systems for Liquid Hydrogen Storage Tanks

    Science.gov (United States)

    Sass, J. P.; Fesmire, J. E.; Nagy, Z. F.; Sojourner, S. J.; Morris, D. L.; Augustynowicz, S. D.

    2008-03-01

    A technology demonstration test project was conducted by the Cryogenics Test Laboratory at the Kennedy Space Center (KSC) to provide comparative thermal performance data for glass microspheres, referred to as bubbles, and perlite insulation for liquid hydrogen tank applications. Two identical 1/15th scale versions of the 3,200,000 liter spherical liquid hydrogen tanks at Launch Complex 39 at KSC were custom designed and built to serve as test articles for this test project. Evaporative (boil-off) calorimeter test protocols, including liquid nitrogen and liquid hydrogen, were established to provide tank test conditions characteristic of the large storage tanks that support the Space Shuttle launch operations. This paper provides comparative thermal performance test results for bubbles and perlite for a wide range of conditions. Thermal performance as a function of cryogenic commodity (nitrogen and hydrogen), vacuum pressure, insulation fill level, tank liquid level, and thermal cycles will be presented.

  13. Review of sensors for the in situ chemical characterization of the Hanford underground storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, K.R.; Mayes, E.L.

    1994-07-29

    Lawrence Livermore National Laboratory (LLNL), in the Technical Task Plan (TTP) SF-2112-03 subtask 2, is responsible for the conceptual design of a Raman probe for inclusion in the in-tank cone penetrometer. As part of this task, LLNL is assigned the further responsibility of generating a report describing a review of sensor technologies other than Raman that can be incorporated in the in-tank cone penetrometer for the chemical analysis of the tank environment. These sensors would complement the capabilities of the Raman probe, and would give information on gaseous, liquid, and solid state species that are insensitive to Raman interrogation. This work is part of a joint effort involving several DOE laboratories for the design and development of in-tank cone penetrometer deployable systems for direct UST waste characterization at Westinghouse Hanford Company (WHC) under the auspices of the U.S. Department of Energy (DOE) Underground Storage Tank Integrated Demonstration (UST-ID).

  14. Temperature distribution of a hot water storage tank in a simulated solar heating and cooling system

    Science.gov (United States)

    Namkoong, D.

    1976-01-01

    A 2,300-liter hot water storage tank was studied under conditions simulating a solar heating and cooling system. The initial condition of the tank, ranging from 37 C at the bottom to 94 C at the top, represented a condition midway through the start-up period of the system. During the five-day test period, the water in the tank gradually rose in temperature but in a manner that diminished its temperature stratification. Stratification was found not to be an important factor in the operation of the particular solar system studied.

  15. Emission characteristics of VOCs from three fixed-roof p-xylene liquid storage tanks.

    Science.gov (United States)

    Lu, Chungsying; Huang, Hsiaoyun; Chang, Shenteng; Hsu, Shihchieh

    2013-08-01

    This study evaluates emission characteristics of volatile organic compounds (VOCs) caused by standing loss (L S) and working loss (L W) of three vertical fixed-roof p-xylene (p-X) liquid tanks during 1-year storage and filling operation. The annual net throughput of the tanks reached 70,446 t, resulting in 9,425 kg of p-X vapor emission including 5,046 kg of L S (53.54 %) and 4,379 kg of L W (46.46 %). The estimated L W of AP-42 displayed better agreement with the measured values of a VOC detector than the estimated L S of AP-42. The L S was best correlated with the liquid height of the tanks, while the L W was best correlated with the net throughput of the tanks. As a result, decreasing vapor space volume of the tanks and avoiding high net throughput of the tanks in a high ambient temperature period were considered as effective means to lessen VOC emission from the fixed-roof organic liquid storage tank.

  16. HYDRODYNAMIC LOADS ON OIL STORAGE TANKS WITH INTERIOR SEMI-POROUS BARRIERS UNDER EARTHQUAKES

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The estimation of the hydrodynamic loading on cylindrical oilstorage tank during earthquakes is of fundamental importance in the anti-seismic design. Interior semi-porous barriers are considered being effective to reduce the hydrodynamic response of the inner fluid and the loading on the tank wall. A reduced two-dimensional source distribution method and sub-region matching technique are developed for the prediction of three-dimensional hydrodynamic forces on oil storage tanks of arbitrary sections with interior semi-porous barriers of different configurations under earthquake excitations.Excellent agreement is observed between the present results and the corresponding analytical results for a circular cylindrical oil tank with a concentric interior semi-porous barrier,which shows the validity and effectiveness of the present method. A clear view of the influence of semi-porous barriers on the hydrodynamic response of tanks during earthquakes is obtained by the analyses of computational results, which may offer some guidance to the corresponding anti-seismic design for oil storage tanks and similar structures. The method is also extended to include the effects of the elastic vibrations of the tank.

  17. FINAL REPORT - Development of High Pressure Hydrogen Storage Tank for Storage and Gaseous Truck Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, Donald [Hexagon Lincoln LLC, Lincoln, NE (United States)

    2017-08-04

    The “Development of High Pressure Hydrogen Storage Tanks for Storage and Gaseous Truck Delivery” project [DE-FG36-08GO18062] was initiated on 01 July 2008. Hexagon Lincoln (then Lincoln Composites) received grant funding from the U.S. Department of Energy to support the design and development of an improved bulk hauling and storage solution for hydrogen in terms of cost, safety, weight and volumetric efficiency. The development of this capability required parallel development and qualification of large all-composites pressure vessels, a custom ISO container to transport and store said tanks, and performance of trade studies to identify optimal operating pressure for the system. Qualification of the 250 bar TITAN® module was completed in 2009 with supervision from the American Bureau of Shipping [ABS], and the equipment has been used internationally for bulk transportation of fuel gases since 2010. Phase 1 of the project was successfully completed in 2012 with the issuance of USDOT SP 14951, the special permit authorizing the manufacture, marking, sale and use of TITAN® Mobile Pipeline® equipment in the United States. The introduction of tube trailers with light weight composite tankage has meant that 2 to 3 times as much gaseous fuel can be transported with each trip. This increased hauling efficiency offers dramatically reduced operating costs and has enabled a profitable business model for over-the-road compressed natural gas delivery. The economic drivers of this business opportunity vary from country to country and region to region, but in many places gas distribution companies have realized profitable operations. Additional testing was performed in 2015 to characterize hydrogen-specific operating protocols for use of TITAN® systems in CHG service at 250 bar. This program demonstrated that existing compression and decompression methodologies can efficiently and safely fill and unload lightweight bulk hauling systems. Hexagon Lincoln and U.S. DOE agreed

  18. Closure Report for Corrective Action Unit 135: Areas 25 Underground Storage Tanks, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    D. H. Cox

    2001-06-01

    Corrective Action Unit (CAU) 135, Area 25 Underground Storage Tanks, was closed in accordance with the approved Corrective Action Plan (DOE/NV, 2000). CAU 135 consists of three Corrective Action Sites (CAS). Two of these CAS's were identified in the Corrective Action Investigation Data Quality Objective meeting as being improperly identified as underground storage tanks. CAS 25-02-03 identified as the Deluge Valve Pit was actually an underground electrical vault and CAS 25-02-10 identified as an Underground Storage Tank was actually a former above ground storage tank filled with demineralized water. Both of these CAS's are recommended for a no further action closure. CAS 25-02-01 the Underground Storage Tanks commonly referred to as the Engine Maintenance Assembly and Disassembly Waste Holdup Tanks and Vault was closed by decontaminating the vault structure and conducting a radiological verification survey to document compliance with the Nevada Test Site unrestricted use release criteria. The Area 25 Underground Storage Tanks, (CAS 25-02-01), referred to as the Engine Maintenance, Assembly, and Disassembly (E-MAD) Waste Holdup Tanks and Vault, were used to receive liquid waste from all of the radioactive and cell service area drains at the E-MAD Facility. Based on the results of the Corrective Action Investigation conducted in June 1999, discussed in ''The Corrective Action Investigation Plan for Corrective Action Unit 135: Area 25 Underground Storage Tanks, Nevada Test Site, Nevada'' (DOE/NV, 199a), one sample from the radiological survey of the concrete vault interior exceeded radionuclide preliminary action levels. The analytes from the sediment samples exceeded the preliminary action levels for polychlorinated biphenyls, Resource Conservation and Recovery Act metals, total petroleum hydrocarbons as diesel-range organics, and radionuclides. The CAU 135 closure activities consisted of scabbling radiological ''hot spots

  19. Lower Colorado River GRP Underground Storage Tank Sites (Closed), Nevada, 2012, Nevada Division of Environmental Protection Bureau of Corrective Actions

    Data.gov (United States)

    U.S. Environmental Protection Agency — The BCA layers are derived from a database for Federally Regulated Underground Storage Tanks (UST) and a database for Remediation and Leaking Underground Storage...

  20. 40 CFR 63.1253 - Standards: Storage tanks.

    Science.gov (United States)

    2010-07-01

    ... trucks and 49 CFR 173.31 for railcars. (3) Hazardous air pollutants must only be unloaded from tank... emission monitoring requirements of § 63.1258(b)(5). (e) Planned routine maintenance. The specifications... periods of planned routine maintenance. Periods of planned routine maintenance of the control...

  1. Design of LNG/L-CNG filling station%LNG/L-CNG加气站的设计

    Institute of Scientific and Technical Information of China (English)

    张玮

    2014-01-01

    介绍了LNG/L-CNG汽车加气站的主要工艺设备:LNG储罐、LNG潜液泵、卸车增压器、EAG加热器、LNG高压柱塞泵、高压气化器、CNG储气瓶、加气机和顺序控制盘等;同时还介绍了设计过程中以上工艺设备选用的计算方法以及管道设计应注意的问题,包括管路的应力补偿、管子及管件的选材、管道绝热结构及材料的选用等。%The major equipments about LNG/L-CNG filling stations were introduced ,inclu-ding LNG storage tanks ,LNG submersible pump ,unloading supercharger ,EAG heater ,LNG high-pressure piston pump ,high-pressure gasifier ,CNG gas cylinders ,dispensers ,sequence con-trol panel and so on .The calculation method of above equipments selection in the process of de-signing was also introduced .Problems like piping stress compensation ,selection of pipe and fit-tings materials ,selection of heat insulation structure and materials should be noticed in the de-sig n .

  2. Modelling of a solid oxide fuel cell CHP system coupled with a hot water storage tank for a single household

    DEFF Research Database (Denmark)

    Liso, Vincenzo; Zhao, Yingru; Yang, Wenyuan

    2015-01-01

    In this paper a solid oxide fuel cell (SOFC) system for cogeneration of heat and power integrated with a stratified heat storage tank is studied. The use of a storage tank with thermal stratification allows one to increase the annual operating hours of CHP: heat can be produced when the request...

  3. 石油储罐机械清洗系统%Large Oil Storage Tanks Mechanical Cleaning System

    Institute of Scientific and Technical Information of China (English)

    黄崇林; 蔡业彬; 何宏鹰

    2013-01-01

    Oil storage tanks need to be cleaned regularly during using .T he oil storage tanks me-chanical cleaning techniques is introduced ,including the main components of the oil storage tanks mechanical cleaning system for vacuum suction module device ,heat exchanger cleaning module e-quipment ,washing machines ,etc .The mechanical cleaning process of oil storage tanks is elabo-rated and the effective of the mechanical cleaning system of oil storage tanks is analyzed .%  对石油储罐机械清洗系统的主要组成部分真空抽吸模块设备、换热清洗模块设备、清洗机等进行了介绍,并对石油储罐机械清洗系统效益进行了分析。

  4. Ormosil Beads for Insulation of Ground Cryogenic Storage Tanks Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced materials are required to insulate cryogenic storage and distribution systems for liquid propellants such as hydrogen and oxygen, used in orbital transfer...

  5. 78 FR 70076 - Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and...

    Science.gov (United States)

    2013-11-22

    ... COMMISSION Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and... Guidance (LR-ISG), LR-ISG-2012-02, ``Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric... aging management programs (AMPs), aging management review (AMR) items, and definitions in NUREG-...

  6. Borehole Miner - Extendible Nozzle Development for Radioactive Waste Dislodging and Retrieval from Underground Storage Tanks

    Energy Technology Data Exchange (ETDEWEB)

    CW Enderlin; DG Alberts; JA Bamberger; M White

    1998-09-25

    This report summarizes development of borehole-miner extendible-nozzle water-jetting technology for dislodging and retrieving salt cake, sludge} and supernate to remediate underground storage tanks full of radioactive waste. The extendible-nozzle development was based on commercial borehole-miner technology.

  7. Modification of a liquid hydrogen tank for integrated refrigeration and storage

    Science.gov (United States)

    Swanger, A. M.; Jumper, K. M.; Fesmire, J. E.; Notardonato, W. U.

    2015-12-01

    The modification and outfitting of a 125,000-liter liquid hydrogen tank was performed to provide integrated refrigeration and storage capability. These functions include zero boil-off, liquefaction, and densification and therefore require provisions for sub-atmospheric tank pressures within the vacuum-jacketed, multilayer insulated tank. The primary structural modification was to add stiffening rings inside the inner vessel. The internal stiffening rings were designed, built, and installed per the ASME Boiler and Pressure Vessel Code, Section VIII, to prevent collapse in the case of vacuum jacket failure in combination with sub-atmospheric pressure within the tank. For the integrated refrigeration loop, a modular, skeleton-type heat exchanger, with refrigerant temperature instrumentation, was constructed using the stiffening rings as supports. To support the system thermal performance testing, three custom temperature rakes were designed and installed along the 21-meter length of the tank, once again using rings as supports. The temperature rakes included a total of 20 silicon diode temperature sensors mounted both vertically and radially to map the bulk liquid temperature within the tank. The tank modifications were successful and the system is now operational for the research and development of integrated refrigeration technology.

  8. Simplified design and evaluation of liquid storage tanks relative to earthquake loading

    Energy Technology Data Exchange (ETDEWEB)

    Poole, A.B.

    1994-06-01

    A summary of earthquake-induced damage in liquid storage tanks is provided. The general analysis steps for dynamic response of fluid-filled tanks subject to horizontal ground excitation are discussed. This work will provide major attention to the understanding of observed tank-failure modes. These modes are quite diverse in nature, but many of the commonly appearing patterns are believed to be shell buckling. A generalized and simple-to-apply shell loading will be developed using Fluegge shell theory. The input to this simplified analysis will be horizontal ground acceleration and tank shell form parameters. A dimensionless parameter will be developed and used in predictions of buckling resulting from earthquake-imposed loads. This prediction method will be applied to various tank designs that have failed during major earthquakes and during shaker table tests. Tanks that have not failed will also be reviewed. A simplified approach will be discussed for early design and evaluation of tank shell parameters and materials to provide a high confidence of low probability of failure during earthquakes.

  9. Closure Report for Corrective Action Unit 130: Storage Tanks Nevada Test Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Alfred Wickline

    2009-03-01

    This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 130: Storage Tanks, Nevada Test Site, Nevada. This CR complies with the requirements of the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. The corrective action sites (CASs) within CAU 130 are located within Areas 1, 7, 10, 20, 22, and 23 of the Nevada Test Site. Corrective Action Unit 130 is comprised of the following CASs: • 01-02-01, Underground Storage Tank • 07-02-01, Underground Storage Tanks • 10-02-01, Underground Storage Tank • 20-02-03, Underground Storage Tank • 20-99-05, Tar Residue • 22-02-02, Buried UST Piping • 23-02-07, Underground Storage Tank This CR provides documentation supporting the completed corrective action investigations and provides data confirming that the closure objectives for CASs within CAU 130 were met. To achieve this, the following actions were performed: • Reviewed the current site conditions, including the concentration and extent of contamination. • Implemented any corrective actions necessary to protect human health and the environment. • Properly disposed of corrective action and investigation-derived wastes. From August 4 through September 30, 2008, closure activities were performed as set forth in the Streamlined Approach for Environmental Restoration Plan for CAU 130, Storage Tanks, Nevada Test Site, Nevada. The purposes of the activities as defined during the data quality objectives process were: • Determine whether contaminants of concern (COCs) are present. • If COCs are present, determine their nature and extent, implement appropriate corrective actions, confirm that no residual contamination is present, and properly dispose of wastes. Constituents detected during the closure activities were evaluated against final action levels to identify

  10. Lightweight Tanks for Storing Liquefied Natural Gas

    Science.gov (United States)

    DeLay, Tom

    2008-01-01

    Single-walled, jacketed aluminum tanks have been conceived for storing liquefied natural gas (LNG) in LNG-fueled motor vehicles. Heretofore, doublewall steel tanks with vacuum between the inner and outer walls have been used for storing LNG. In comparison with the vacuum- insulated steel tanks, the jacketed aluminum tanks weigh less and can be manufactured at lower cost. Costs of using the jacketed aluminum tanks are further reduced in that there is no need for the vacuum pumps heretofore needed to maintain vacuum in the vacuum-insulated tanks.

  11. Mathematical Model Based on BP Neural Network Algorithm for the Deflection Identification of Storage Tank and Calibration of Tank Capacity Chart

    Directory of Open Access Journals (Sweden)

    Caihong Li

    2013-01-01

    Full Text Available The tank capacity chart calibration problem of two oil tanks with deflection was studied, one of which is an elliptical cylinder storage tank with two truncated ends and another is a cylinder storage tank with two spherical crowns. Firstly, the function relation between oil reserve and oil height based on the integral method was precisely deduced, when the storage tank has longitudinal inclination but has no deflection. Secondly, the nonlinear optimization model which has both longitudinal inclination parameter α and lateral deflection parameter β was constructed, using cut-complement method and approximate treatment method. Then the deflection tank capacity chart calibration with a 10 cm oil level height interval was worked out. Lastly, the tank capacity chart was corrected by BP neural network algorithm and got proportional error of theoretical and experimental measurements ranges from 0% to 0.00015%. Experimental results demonstrated that the proposed method has better performance in terms of tank capacity chart calibration accuracy compared with other existing approaches and has a strongly practical significance.

  12. LNG project - contractual aspects

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Bruno Almeida

    2008-07-01

    This paper intends to provide from the legal point of view an outline of the main challenges of a LNG project in the upstream, regulatory aspects, liquefaction, financing and midstream through a basic checklist; an overview of the contractual complexity of a LNG project; some basic discussion of particular LNG contract clauses; and a comparative analysis between the classic clauses of a Gas Transportation Agreement (GTA) through a gas pipeline and LNG logistic. (author)

  13. Optimal selection of intermediate storage tank capacity in a periodic batch/semicontinuous process

    Energy Technology Data Exchange (ETDEWEB)

    Karimi, I.A.; Reklaitis, G.V.

    1983-07-01

    Batch/semicontinuous chemical plants are usually designed either by assuming infinite intermediate storage or by assuming that the units themselves act as storage vessels, while the storage vessels are sized by rules of thumb or experience. In this paper, the case of an intermediate storage vessel which links one upstream batch/semicontinuous unit to one downstream batch/semicontinuous unit is analyzed. The units are assumed to operate with fixed cycle times and capacities. Expressions for determining the minimum storage tank capacity necessary to decouple the two units are derived from a mathematical model of the periodic process. Effects of the relative starting times of the two units on the required storage capacity are determined, thus suggesting the optimum process timings to minimize the same. Application of the results is illustrated by an example.

  14. Implications of the modelling of stratified hot water storage tanks in the simulation of CHP plants

    Energy Technology Data Exchange (ETDEWEB)

    Campos Celador, A., E-mail: alvaro.campos@ehu.es [ENEDI Research Group-University of the Basque Country, Departamento de Maquinas y Motores Termicos, E.T.S.I. de Bilbao Alameda de Urquijo, s/n 48013 Bilbao, Bizkaia (Spain); Odriozola, M.; Sala, J.M. [ENEDI Research Group-University of the Basque Country, Departamento de Maquinas y Motores Termicos, E.T.S.I. de Bilbao Alameda de Urquijo, s/n 48013 Bilbao, Bizkaia (Spain)

    2011-08-15

    Highlights: {yields} Three different modelling approaches for simulation of hot water tanks are presented. {yields} The three models are simulated within a residential cogeneration plant. {yields} Small differences in the results are found by an energy and exergy analysis. {yields} Big differences between the results are found by an advanced exergy analysis. {yields} Results on the feasibility study are explained by the advanced exergy analysis. - Abstract: This paper considers the effect that different hot water storage tank modelling approaches have on the global simulation of residential CHP plants as well as their impact on their economic feasibility. While a simplified assessment of the heat storage is usually considered in the feasibility studies of CHP plants in buildings, this paper deals with three different levels of modelling of the hot water tank: actual stratified model, ideal stratified model and fully mixed model. These three approaches are presented and comparatively evaluated under the same case of study, a cogeneration plant with thermal storage meeting the loads of an urbanisation located in the Bilbao metropolitan area (Spain). The case of study is simulated by TRNSYS for each one of the three modelling cases and the so obtained annual results are analysed from both a First and Second-Law-based viewpoint. While the global energy and exergy efficiencies of the plant for the three modelling cases agree quite well, important differences are found between the economic results of the feasibility study. These results can be predicted by means of an advanced exergy analysis of the storage tank considering the endogenous and exogenous exergy destruction terms caused by the hot water storage tank.

  15. Experimental study on the storage performance of high-vacuum-multilayer-insulation tank after sudden, catastrophic loss of insulating vacuum

    Science.gov (United States)

    Xie, G. F.; Li, X. D.; Wang, R. S.

    2012-05-01

    High-vacuum-multilayer-insulation (HVMLI) cryogenic tank is one kind of dangerous pressure vessels. One of the worst accidents that may occur in a high-vacuum-multilayer-insulation (HVMLI) cryogenic tank is a sudden, catastrophic loss of insulating vacuum (SCLIV). The influence of SCLIV on storage performance for a HVMLI cryogenic tank is experimentally studied in this paper. A test rig was built up and experiments were conducted using LN2 as the test medium. The cryogenic tank was tested in the conditions of various combinations with different initial liquid level and number of insulation layers. Some important conclusions for storage performance with a vacuum-lost HVMLI cryogenic tank have been obtained. The experimental results show that the numbers of insulation layers and the initial liquid level have obvious effect on the storage performance after SCLIV for cryogenic tanks.

  16. Performance of a solid oxide fuel cell CHP system coupled with a hot water storage tank for single household

    DEFF Research Database (Denmark)

    Liso, Vincenzo; Zhao, Yingru; Yang, Wenyuan

    2014-01-01

    of heat used for thermal loads of the residence. Two fuels are considered, namely syngas and natural gas. The tank model considers the temperature gradients over the tank height. The results of the numerical simulation is used to size the SOFC system and storage heat tank to provide energy for a small...... household using two different fuels. In particular it was shown that in the case of syngas, due to larger system heat output, a larger tank volume was required in order to accumulate unused heat over the night. The detailed description of the tank model will be useful to energy system modelers when sizing......In this paper a solid oxide fuel cell (SOFC) system for cogeneration of heat and power integrated with a stratified heat storage tank is studied. Thermal stratification in the tank increases the heat recovery performance as it allows existence of a temperature gradient with the benefit...

  17. Rock-bed thermocline storage: A numerical analysis of granular bed behavior and interaction with storage tank

    Science.gov (United States)

    Sassine, Nahia; Donzé, Frédéric-Victor; Bruch, Arnaud; Harthong, Barthélemy

    2017-06-01

    Thermal Energy Storage (TES) systems are central elements of various types of power plants operated using renewable energy sources. Packed bed TES can be considered as a cost-effective solution in concentrated solar power plants (CSP). Such a device is made up of a tank filled with a granular bed through which heat-transfer fluid circulates. However, in such devices, the tank might be subjected to catastrophic failure induced by a mechanical phenomenon known as thermal ratcheting. Thermal stresses are accumulated during cycles of loading and unloading until the failure happens. This paper aims at studying the evolution of tank wall stresses over granular bed thermal cycles, taking into account both thermal and mechanical loads, with a numerical model based on the discrete element method (DEM). Simulations were performed to study two different thermal configurations: (i) the tank is heated homogenously along its height or (ii) with a vertical gradient of temperature. Then, the resulting loading stresses applied on the tank are compared as well the response of the internal granular material.

  18. Analysis of Influence of Heat Insulation on the Thermal Regime of Storage Tanks with Liquefied Natural Gas

    Directory of Open Access Journals (Sweden)

    Maksimov Vyacheslav I.

    2016-01-01

    Full Text Available Is numerically investigated the process of convective heat transfer in the reservoirs of liquefied natural gas (LNG. The regimes of natural convection in a closed rectangular region with different intensity of heat exchange at the external borders are investigated. Is solved the time-dependent system of energy and Navier-Stokes equations in the dimensionless variables “vorticity – the stream function”. Are obtained distributions of the hydrodynamic parameters and temperatures, that characterize basic regularities of the processes. The special features of the formation of circulation flows are isolated and the analysis of the temperature distribution in the solution region is carried out. Is shown the influence of geometric characteristics and intensity of heat exchange on the outer boundaries of reservoir on the temperature field in the LNG storage.

  19. Acute collective gas poisoning at work in a manure storage tank.

    Science.gov (United States)

    Żaba, Czesław; Marcinkowski, Jerzy T; Wojtyła, Andrzej; Tężyk, Artur; Tobolski, Jarosław; Zaba, Zbigniew

    2011-01-01

    Cases of deaths in manure or septic tanks are rare in legal-medical practice, more frequently as unfortunate occupational accidents. Poisoning with toxic gases, especially with hydrogen sulfide, is reported as the cause of death, while the exhaustion of oxygen in the air is omitted with the simultaneous excess of carbon dioxide. In such cases, determination of the direct cause of death constitutes a big problem because post-mortem examination does not reveal the specific changes. A case of acute collective poisoning by gases in a manure storage tank is presented of 5 agricultural workers, 2 of whom died. While explaining the cause of poisoning and deaths, toxicological blood tests were performed in the victims of the accident, as well as gases inside the manure storage tank. The post-mortem examinations and toxicological blood tests performed did not allow determination of the direct cause of death. Toxicological tests of gases from inside the manure tank showed a very low concentration of oxygen, with a simultaneous very high concentration of carbon dioxide, and a considerable level of hydrogen sulfide. The cause of fainting of three and deaths of two workers was not the poisoning with hydrogen sulfide, but oxygen deficiency in the air of the tank.

  20. Investigating and modeling of the effects of condensate storage tank fire in a refinery

    Directory of Open Access Journals (Sweden)

    Mohammad Kamaei

    2015-12-01

    Full Text Available Background & objective: Oil storage tanks are major industrial facilities which always pose risks of toxic substance release, fires and explosions. Fire has been recognized as the most common risk associated with such facilities, while explosion is the most important one in terms of ability to claim human lives and damage property. The current study aimed at investigating and modeling the effects of fires occurring in a gas condensate tank farm, according to which the level of possible emergencies were specified using the guidelines provided by the Center for Chemical Process Safety. Lastly, control measures were recommended. Methods: In the present study, the release and leakage of gas condensate from floating roof tanks were assessed using HAZOP method. Then, using PHAST software, the amount of radiation intensity received by the surrounding environment was determined, safe boundaries were computed, and according to the CCPS standard the emergency levels were determined. Results: modeling was performed based on the maximum capacity of tanks for both cold and hot seasons. The results revealed that safe distance for a maximum amount of irradiation density (4 KW/m2 related to a sudden release were 60 and 140 meters, respectively. Conclusion: according to the current condition of the plants and storage tanks, a plan was recommended for emergency management and practical suggestions were provided to improve the reliability and consistency.

  1. Strength Analysis of Small and Medium LNG Carrier Hull Structure near the Bearing of Cargo Tank%中小型LNG船鞍座及附近船体结构强度分析

    Institute of Scientific and Technical Information of China (English)

    杨青松; 陆丛红; 纪卓尚

    2011-01-01

    The structure and equipment of the small and medium LNG carrier are quite different from large-scale LNG carrier.When the ship is sailing at sea, the static and dynamic loads act on the bearings simultaneously.So the structure stress of the bearings will be very complicated.The stress distribution at the bearings and at the nearby hull structure is directly related to the reliability and security of this type of LNG carrier.The types and the functions of the C-shape independent liquid tank's bearing of the small and medium LNG carrier are described in detail in this paper.Combining with the Rules for the Construction and Equipment of Ships Carrying Liquefied Gases in Bulk of the China Classification Society, the radial force distribution function of the bearing-load area is deduced under various working conditions, including still water, heave only, rolling only,and heave and rolling simultaneously.The finite element model for the bearings and the nearby hull structure of a 6400m3 LNG carier is created.The loads required by the rules are imposed on the model with loads superposed method.The stress results are obtained and analyzed, and the dangerous working condition and the dangerous position are found.Referring to the stress distribution, structure improvement measures are provided.The research is meaningful for structure strength analysis and structure design of the similar bearing and the nearby hull structure.%中小型LNG船与传统大型LNG船相比,在结构设置和内部设备等方面有着很大差别.船在海上航行时,受动、静载荷的综合作用,鞍座的应力分布比较复杂.因此鞍座及附近船体的应力分布情况直接关系到此种LNG运输船使用的可靠性与安全性.详细介绍了中小型LNG船C型独立液货舱货罐鞍座的结构及其承载作用.结合中国船级社,推导出船舶在静水、仅垂荡、仅横摇以及垂荡和横摇并存状态下鞍座承载区域所受径向力的分布函数.利用 ANSYS

  2. Vehicular hydrogen storage using lightweight tanks (regenerative fuel cell systems)

    Energy Technology Data Exchange (ETDEWEB)

    Mitlitsky, F; Myers, B; Weisberg, A H

    1999-06-01

    Energy storage systems with extremely high specific energy (>400 Wh/kg) have been designed that use lightweight tankage to contain the gases generated by reversible (unitized) regenerative fuel cells (URFCs). Lawrence Livermore National Laboratory (LLNL) will leverage work for aerospace applications supported by other sponsors (including BMDO, NASA, and USAF) to develop URFC systems for transportation and utility applications. Lightweight tankage is important for primary fuel cell powered vehicles that use on-board storage of hydrogen. Lightweight pressure vessels with state-of-the-art performance factors were designed, and prototypes are being fabricated to meet the DOE 2000 goals (4000 Wh/kg, 12% hydrogen by weight, 700 Wh/liter, and $20/kWh in high volume production). These pressure vessels use technologies that are easily adopted by industrial partners. Advanced liners provide permeation barriers for gas storage and are mandrels for composite overwrap. URFCs are important to the efficient use of hydrogen as a transportation fuel and enabler of renewable energy. H{sub 2}/halogen URFCs may be advantageous for stationary applications whereas H{sub 2}/O{sub 2} or H{sub 2}/air URFCs are advantageous for vehicular applications. URFC research and development is required to improve performance (efficiency), reduce catalyst loading, understand engineering operation, and integrate systems. LLNL has the experimental equipment and advanced URFC membrane electrode assemblies (some with reduced catalyst loading) for evaluating commercial hardware (not funded by DOE in FY1999).

  3. Performance of rainwater harvesting system based on roof catchment area and storage tank capacity

    Directory of Open Access Journals (Sweden)

    Juliana Imroatul C.

    2017-01-01

    Full Text Available Increasing population growth has created problems in water resources. Natural water resources become progressively more expensive and difficult to develop. In addition, it is also becoming increasingly polluted and difficult to obtain. Many countries shown a resurgent interest in the use of rainwater harvesting (RWH technique to overcome these problems. There are several factors that will influence the RWH performance, such as the rainfall, catchment area, storage tank capacity, and water demand. The performance parameter determines by the volumetric reliability, time reliability, and yield. The RWH system used in this study is a simple RWH system that utilizes roof as a catchment area, pipes as a distribution system and tank as a storage. An analysis is carried out to investigate the effect of altering the large of the catchment area and storage tank capacity to the RWH system performance parameters. A suitable behavioral model based on the water balance method is implemented to evaluate the inflow, outflow, and the storage volume. Results demonstrate that with up to 15 years daily rainfall data in 15 cities in Indonesia, the most influential parameters on the performance of RWH system is the time reliability.

  4. Atmospheric Pressure Effects on Cryogenic Storage Tank Boil-Off

    Science.gov (United States)

    Sass, J. P.; Frontier, C. R.

    2007-01-01

    The Cryogenics Test Laboratory (CTL) at the Kennedy Space Center (KSC) routinely utilizes cryostat test hardware to evaluate comparative and absolute thermal conductivities of a wide array of insulation systems. The test method is based on measurement of the flow rate of gas evolved due to evaporative boil-off of a cryogenic liquid. The gas flow rate typically stabilizes after a period of a couple of hours to a couple of days, depending upon the test setup. The stable flow rate value is then used to calculate the thermal conductivity for the insulation system being tested. The latest set of identical cryostats, 1,000-L spherical tanks, exhibited different behavior. On a macro level, the flow rate did stabilize after a couple of days; however the stable flow rate was oscillatory with peak to peak amplitude of up to 25 percent of the nominal value. The period of the oscillation was consistently 12 hours. The source of the oscillation has been traced to variations in atmospheric pressure due to atmospheric tides similar to oceanic tides. This paper will present analysis of this phenomenon, including a calculation that explains why other cryostats are not affected by it.

  5. Reducing drinking water supply chemical contamination: risks from underground storage tanks.

    Science.gov (United States)

    Enander, Richard T; Hanumara, R Choudary; Kobayashi, Hisanori; Gagnon, Ronald N; Park, Eugene; Vallot, Christopher; Genovesi, Richard

    2012-12-01

    Drinking water supplies are at risk of contamination from a variety of physical, chemical, and biological sources. Ranked among these threats are hazardous material releases from leaking or improperly managed underground storage tanks located at municipal, commercial, and industrial facilities. To reduce human health and environmental risks associated with the subsurface storage of hazardous materials, government agencies have taken a variety of legislative and regulatory actions--which date back more than 25 years and include the establishment of rigorous equipment/technology/operational requirements and facility-by-facility inspection and enforcement programs. Given a history of more than 470,000 underground storage tank releases nationwide, the U.S. Environmental Protection Agency continues to report that 7,300 new leaks were found in federal fiscal year 2008, while nearly 103,000 old leaks remain to be cleaned up. In this article, we report on an alternate evidence-based intervention approach for reducing potential releases from the storage of petroleum products (gasoline, diesel, kerosene, heating/fuel oil, and waste oil) in underground tanks at commercial facilities located in Rhode Island. The objective of this study was to evaluate whether a new regulatory model can be used as a cost-effective alternative to traditional facility-by-facility inspection and enforcement programs for underground storage tanks. We conclude that the alternative model, using an emphasis on technical assistance tools, can produce measurable improvements in compliance performance, is a cost-effective adjunct to traditional facility-by-facility inspection and enforcement programs, and has the potential to allow regulatory agencies to decrease their frequency of inspections among low risk facilities without sacrificing compliance performance or increasing public health risks.

  6. Performance improvement by discharge from different levels in solar storage tanks

    DEFF Research Database (Denmark)

    Furbo, Simon; Andersen, Elsa; Thür, Alexander

    2005-01-01

    The thermal advantages by utilizing discharge from different levels in solar storage tanks are investigated, both for a small SDHW system and for a solar combisystem. The investigations showed that it is possible to increase the thermal performance of both types of systems by using two draw......-off levels from the solar tanks instead of one draw-off level at a fixed position. The best position of the second draw-off level is in the middle or just above the middle of the tank. For the investigated small SDHW system with a realistic draw off hot water temperature of 40°C and 45°C and an auxiliary...

  7. Guidelines for development of structural integrity programs for DOE high-level waste storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Bandyopadhyay, K.; Bush, S.; Kassir, M.; Mather, B.; Shewmon, P.; Streicher, M.; Thompson, B.; Rooyen, D. van; Weeks, J.

    1997-01-01

    Guidelines are provided for developing programs to promote the structural integrity of high-level waste storage tanks and transfer lines at the facilities of the Department of Energy. Elements of the program plan include a leak-detection system, definition of appropriate loads, collection of data for possible material and geometric changes, assessment of the tank structure, and non-destructive examination. Possible aging degradation mechanisms are explored for both steel and concrete components of the tanks, and evaluated to screen out nonsignificant aging mechanisms and to indicate methods of controlling the significant aging mechanisms. Specific guidelines for assessing structural adequacy will be provided in companion documents. Site-specific structural integrity programs can be developed drawing on the relevant portions of the material in this document.

  8. Assessment of concentration mechanisms for organic wastes in underground storage tanks at Hanford

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, M.A.; Burger, L.L.; Nelson, D.A.; Ryan, J.L. (Pacific Northwest Lab., Richland, WA (United States)); Zollars, R.L. (Washington State Univ., Pullman, WA (United States))

    1992-09-01

    Pacific Northwest Laboratory (PNL) has conducted an initial conservative evaluation of physical and chemical processes that could lead to significant localized concentrations of organic waste constituents in the Hanford underground storage tanks (USTs). This evaluation was part of ongoing studies at Hanford to assess potential safety risks associated with USTs containing organics. Organics in the tanks could pose a potential problem if localized concentrations are high enough to propagate combustion and are in sufficient quantity to produce a large heat and/or gas release if in contact with a suitable oxidant. The major sources of oxidants are oxygen in the overhead gas space of the tanks and sodium nitrate and nitrite either as salt cake solids or dissolved in the supernatant and interstitial liquids.

  9. Power Reactant Storage Assembly (PRSA) (Space Shuttle). PRSA hydrogen and oxygen DVT tank refurbishment

    Science.gov (United States)

    1993-07-01

    The Power Reactant Storage Assembly (PRSA) liquid hydrogen Development Verification Test (H2 DVT) tank assembly (Beech Aircraft Corporation P/N 15548-0116-1, S/N 07399000SHT0001) and liquid oxygen (O2) DVT tank assembly (Beech Aircraft Corporation P/N 15548-0115-1, S/N 07399000SXT0001) were refurbished by Ball Electro-Optics and Cryogenics Division to provide NASA JSC, Propulsion and Power Division, the capability of performing engineering tests. The refurbishments incorporated the latest flight configuration hardware and avionics changes necessary to make the tanks function like flight articles. This final report summarizes these refurbishment activities. Also included are up-to-date records of the pressure time and cycle histories.

  10. A mounded spherical storage tank at Papeete; Une sphere sous talus a Papeete

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2003-09-01

    Because demand for liquid petroleum gas (LPG) in French Polynesia is burgeoning, deliveries of the product are on the rise, in particular from New Zealand. In consideration of this, Gaz de Tahiti has had a mounded 1.800 m{sup 3} spherical propane storage tank built by the Tissot group. The new tank joins the ranks of the standard 2.500 m{sup 3} spherical butane tank that Gaz de Tahiti already has at its Papeete site. The slope consists of earth-filled gabions, which are at least one metre thick at any point of the steel structure. The project is proof once again that Gaz de Tahiti has no reason to envy European companies when it comes to technology and development. (authors)

  11. Modelling of a solid oxide fuel cell CHP system coupled with a hot water storage tank for a single household

    DEFF Research Database (Denmark)

    Liso, Vincenzo; Zhao, Yingru; Yang, Wenyuan

    2015-01-01

    In this paper a solid oxide fuel cell (SOFC) system for cogeneration of heat and power integrated with a stratified heat storage tank is studied. The use of a storage tank with thermal stratification allows one to increase the annual operating hours of CHP: heat can be produced when the request...... produced by gasification and natural gas. The tank model considers the temperature gradients over the tank height. The results of the numerical simulation are used to size the SOFC system and storage heat tank to provide energy for a small household using two different fuels. In particular it was shown...... is low (for instance during the night), taking advantage of thermal stratification to increases the heat recovery performance. A model of the SOFC system is presented to estimate the energy required to meet the average electric energy demand of the residence. Two fuels are considered, namely syngas...

  12. Methanoculleus spp. as a biomarker of methanogenic activity in swine manure storage tanks.

    Science.gov (United States)

    Barret, Maialen; Gagnon, Nathalie; Morissette, Bruno; Topp, Edward; Kalmokoff, Martin; Brooks, Stephen P J; Matias, Fernando; Massé, Daniel I; Masse, Lucie; Talbot, Guylaine

    2012-05-01

    Greenhouse gas emissions represent a major problem associated with manure management in the livestock industry. A prerequisite to mitigate methane emissions occurring during manure storage is a clearer understanding of how the microbial consortia involved in methanogenesis function. Here, we have examined manure stored in outdoor tanks from two different farms, at different locations and depths. Physico-chemical and microbiological characterization of these samples indicated differences between each tank, as well as differences within each tank dependent on the depth of sampling. The dynamics of both the bacterial and archaeal communities within these samples were monitored over a 150-day period of anaerobic incubation to identify and track emerging microorganisms, which may be temporally important in the methanogenesis process. Analyses based on DNA fingerprinting of microbial communities identified trends common among all samples as well as trends specific to certain samples. All archaeal communities became enriched with Methanoculleus spp. over time, indicating that the hydrogenotrophic pathway of methanogenesis predominated. Although the emerging species differed in samples obtained from shallow depths compared to deep samples, the temporal enrichment of Methanoculleus suggests that this genus may represent a relevant indicator of methanogenic activity in swine manure storage tanks.

  13. Research on acoustic emission in-service inspection for large above-ground storage tank floors

    Energy Technology Data Exchange (ETDEWEB)

    Mingchun Lin; Yewei Kang; Min Xiong; Juan Zheng; Dongjie Tan [Petrochina Pipeline R and Center, Langfang (China)

    2009-07-01

    Much manpower is needed and a lot of materials are wasted when the floor of large above-ground storage tank (AST) is inspected with conventional methods which need to shut down the tank, then to empty and clean it before inspection. Due to the disadvantages of that, an in-service inspection method using acoustic emission (AE) technology is presented. By this mean the rational inspection plan and integrity evaluation of tank floors can be constructed. First, specific inspection steps are established based on the acoustic emission principle for large AST's floors and the practical condition of AST in order to acquire the AE corrosion data. Second, analysis method of acoustic emission dataset is studied. Finally, maintenance proposes are provided based on results of analysis for the corrosion status of the tank floors. In order to evaluate the performance of our method, an in-service field inspection is practiced on product oil tank with a volume of 5000 cubic meters. Then a traditional inspection procedure using magnetic flux leakage (MFL) technology is followed up. Comparative analysis of the results of the two inspection methods shows that there is consistency in localizing the position of corrosion between them. The feasibility of in-service inspection of AST's floors with AE is demonstrated. (author)

  14. Self-pressurization of a spherical liquid hydrogen storage tank in a microgravity environment

    Science.gov (United States)

    Lin, C. S.; Hasan, M. M.

    1992-01-01

    Thermal stratification and self-pressurization of partially filled liquid hydrogen (LH2) storage tanks under microgravity condition is studied theoretically. A spherical tank is subjected to a uniform and constant wall heat flux. It is assumed that a vapor bubble is located in the tank center such that the liquid-vapor interface and tank wall form two concentric spheres. This vapor bubble represents an idealized configuration of a wetting fluid in microgravity conditions. Dimensionless mass and energy conservation equations for both vapor and liquid regions are numerically solved. Coordinate transformation is used to capture the interface location which changes due to liquid thermal expansion, vapor compression, and mass transfer at liquid-vapor interface. The effects of tank size, liquid fill level, and wall heat flux on the pressure rise and thermal stratification are studied. Liquid thermal expansion tends to cause vapor condensation and wall heat flux tends to cause liquid evaporation at the interface. The combined effects determine the direction of mass transfer at the interface. Liquid superheat increases with increasing wall heat flux and liquid fill level and approaches an asymptotic value.

  15. Numerical Investigation of LO2 and LCH4 Storage Tanks on the Lunar Surface

    Science.gov (United States)

    Moder, Jeff; Barsi, Stephen; Kassemi, Mohammad

    2008-01-01

    Currently NASA is developing technologies to enable human exploration of the lunar surface for duration of up to 210 days. While trade studies are still underway, a cryogenic ascent stage using liquid oxygen (LO2) and liquid methane (LCH4) is being considered for the Altair lunar lander. For a representative Altair cryogenic ascent stage, we present a detailed storage analysis of the LO2 and LCH4 propellant tanks on the lunar surface for durations of up to 210 days. Both the LO2 and LCH4 propellant tanks are assumed to be pressurized with gaseous helium at launch. A two-phase lumped-vapor computational fluid dynamics model has been developed to account for the presence of a noncondensable gas in the ullage. The CFD model is used to simulate the initial pressure response of the propellant tanks while they are subjected to representative heat leak rates on the lunar surface. Once a near stationary state is achieved within the liquid phase, multizone model is used to extrapolate the solution farther in time. For fixed propellant mass and tank size, the long-term pressure response for different helium mass fractions in both the LO2 and LCH4 tanks is examined.

  16. Characterization and leaching study of sludge from Melton Valley Storage Tank W-25

    Energy Technology Data Exchange (ETDEWEB)

    Collins, J.L.; Egan, B.Z.; Beahm, E.C.; Chase, C.W.; Anderson, K.K.

    1997-08-01

    One of the greatest challenges facing the Department of Energy (DOE) is the remediation of the 100 million gallons of high-level and low-level radioactive waste in the underground storage tanks at its Hanford, Savannah River, Oak Ridge, Idaho, and Fernald sites. Bench-scale batch tests have been conducted with sludge from the Melton Valley Storage Tank (MVST) Facility at Oak Ridge National Laboratory (ORNL) to evaluate separation processes for use in a comprehensive sludge-processing flow sheet for concentrating the radionuclides and reducing the volumes of storage tanks wastes for final disposal. This report discusses the hot cell apparatus, the characterization of the sludge, and the results obtained from a variety of basic and acidic leaching tests of samples of sludge. Approximately 5 L of sludge/supernate from MVST W-25 was retrieved and transferred to a stainless steel tank for mixing and storage in a hot cell. Samples were centrifuged to separate the sludge liquid and the sludge solids. Air-dried samples of sludge were analyzed to determine the concentrations of radionuclides, other metals, and anions. Based upon the air-dried weight, about 41% of the centrifuged, wet sludge solids was water. The major alpha-, gamma-, and beta-emitting radionuclides in the centrifuged, wet sludge solids were {sup 137}Cs, {sup 60}Co, {sup 154}Eu, {sup 241}Am, {sup 244}Cm, {sup 90}Sr, Pu, U, and Th. The other major metals (in addition to the U and Th) and the anions were Na, Ca, Al, K, Mg, NO{sub 3}{sup {minus}}, CO{sub 3}{sup 2{minus}}, OH{sup {minus}}, and O{sub 2{minus}}. The organic carbon content was 3.0 {+-} 1.0%. The pH was 13.

  17. Technical assessment of compressed hydrogen storage tank systems for automotive applications.

    Energy Technology Data Exchange (ETDEWEB)

    Hua, T. Q.; Ahluwalia, R. K.; Peng, J. K.; Kromer, M.; Lasher, S.; McKenney, K.; Law, K.; Sinha, J. (Nuclear Engineering Division); (TIAX, LLC)

    2011-02-09

    The performance and cost of compressed hydrogen storage tank systems has been assessed and compared to the U.S. Department of Energy (DOE) 2010, 2015, and ultimate targets for automotive applications. The on-board performance and high-volume manufacturing cost were determined for compressed hydrogen tanks with design pressures of 350 bar ({approx}5000 psi) and 700 bar ({approx}10,000 psi) capable of storing 5.6 kg of usable hydrogen. The off-board performance and cost of delivering compressed hydrogen was determined for hydrogen produced by central steam methane reforming (SMR). The main conclusions of the assessment are that the 350-bar compressed storage system has the potential to meet the 2010 and 2015 targets for system gravimetric capacity but will not likely meet any of the system targets for volumetric capacity or cost, given our base case assumptions. The 700-bar compressed storage system has the potential to meet only the 2010 target for system gravimetric capacity and is not likely to meet any of the system targets for volumetric capacity or cost, despite the fact that its volumetric capacity is much higher than that of the 350-bar system. Both the 350-bar and 700-bar systems come close to meeting the Well-to-Tank (WTT) efficiency target, but fall short by about 5%. These results are summarized.

  18. METHODOLOGY & CALCULATIONS FOR THE ASSIGNMENT OF WASTE GROUPS FOR THE LARGE UNDERGROUND WASTE STORAGE TANKS AT THE HANFORD SITE

    Energy Technology Data Exchange (ETDEWEB)

    BARKER, S.A.

    2006-07-27

    Waste stored within tank farm double-shell tanks (DST) and single-shell tanks (SST) generates flammable gas (principally hydrogen) to varying degrees depending on the type, amount, geometry, and condition of the waste. The waste generates hydrogen through the radiolysis of water and organic compounds, thermolytic decomposition of organic compounds, and corrosion of a tank's carbon steel walls. Radiolysis and thermolytic decomposition also generates ammonia. Nonflammable gases, which act as dilutents (such as nitrous oxide), are also produced. Additional flammable gases (e.g., methane) are generated by chemical reactions between various degradation products of organic chemicals present in the tanks. Volatile and semi-volatile organic chemicals in tanks also produce organic vapors. The generated gases in tank waste are either released continuously to the tank headspace or are retained in the waste matrix. Retained gas may be released in a spontaneous or induced gas release event (GRE) that can significantly increase the flammable gas concentration in the tank headspace as described in RPP-7771. The document categorizes each of the large waste storage tanks into one of several categories based on each tank's waste characteristics. These waste group assignments reflect a tank's propensity to retain a significant volume of flammable gases and the potential of the waste to release retained gas by a buoyant displacement event. Revision 5 is the annual update of the methodology and calculations of the flammable gas Waste Groups for DSTs and SSTs.

  19. LNG systems for natural gas propelled ships

    Science.gov (United States)

    Chorowski, M.; Duda, P.; Polinski, J.; Skrzypacz, J.

    2015-12-01

    In order to reduce the atmospheric pollution generated by ships, the International Marine Organization has established Emission Controlled Areas. In these areas, nitrogen oxides, sulphur oxides and particulates emission is strongly controlled. From the beginning of 2015, the ECA covers waters 200 nautical miles from the coast of the US and Canada, the US Caribbean Sea area, the Baltic Sea, the North Sea and the English Channel. From the beginning of 2020, strong emission restrictions will also be in force outside the ECA. This requires newly constructed ships to be either equipped with exhaust gas cleaning devices or propelled with emission free fuels. In comparison to low sulphur Marine Diesel and Marine Gas Oil, LNG is a competitive fuel, both from a technical and economical point of view. LNG can be stored in vacuum insulated tanks fulfilling the difficult requirements of marine regulations. LNG must be vaporized and pressurized to the pressure which is compatible with the engine requirements (usually a few bar). The boil-off must be controlled to avoid the occasional gas release to the atmosphere. This paper presents an LNG system designed and commissioned for a Baltic Sea ferry. The specific technical features and exploitation parameters of the system will be presented. The impact of strict marine regulations on the system's thermo-mechanical construction and its performance will be discussed. The review of possible flow-schemes of LNG marine systems will be presented with respect to the system's cost, maintenance, and reliability.

  20. The Gunite Tanks Remediation Project at Oak Ridge National Laboratory; Successful Integration & Deployment of Technologies Results in Remediated Underground Storage Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Billingsley, K.; Bolling, D.

    2002-02-27

    This paper presents an overview of the underground technologies deployed during the cleanup of nine large underground storage tanks (USTs) that contained residual radioactive sludge, liquid low-level waste (LLLW), and other debris. The Gunite Tanks Remediation Project at Oak Ridge National Laboratory (ORNL) was successfully completed in 2001, ending with the stabilization of the USTs and the cleanup of the South Tank Farm. This U.S. Department of Energy (DOE) project was the first of its kind completed in the United States of America. The Project integrated robotic and remotely operated technologies into an effective tank waste retrieval system that safely retrieved more than 348 m3 (92,000 gal) of radioactive sludge and 3.15E+15 Bq (85,000 Ci) of radioactive contamination from the tanks. The Project successfully transferred over 2,385 m3 (630,000 gal) of waste slurry to ORNL's active tank waste management system. The project team avoided over $120 Million in costs and shortened the original baseline schedule by over 10 years. Completing the Gunite Tanks Remediation Project eliminated the risks posed by the aging USTs and the waste they contained, and avoid the $400,000 annual costs associated with maintaining and monitoring the tanks.

  1. METHODOLOGY AND CALCULATIONS FOR THE ASSIGNMENT OF WASTE GROUPS FOR THE LARGE UNDERGROUND WASTE STORAGE TANKS AT THE HANFORD SITE

    Energy Technology Data Exchange (ETDEWEB)

    WEBER RA

    2009-01-16

    The Hanford Site contains 177 large underground radioactive waste storage tanks (28 double-shell tanks and 149 single-shell tanks). These tanks are categorized into one of three waste groups (A, B, and C) based on their waste and tank characteristics. These waste group assignments reflect a tank's propensity to retain a significant volume of flammable gases and the potential of the waste to release retained gas by a buoyant displacement gas release event. Assignments of waste groups to the 177 double-shell tanks and single-shell tanks, as reported in this document, are based on a Monte Carlo analysis of three criteria. The first criterion is the headspace flammable gas concentration following release of retained gas. This criterion determines whether the tank contains sufficient retained gas such that the well-mixed headspace flammable gas concentration would reach 100% of the lower flammability limit if the entire tank's retained gas were released. If the volume of retained gas is not sufficient to reach 100% of the lower flammability limit, then flammable conditions cannot be reached and the tank is classified as a waste group C tank independent of the method the gas is released. The second criterion is the energy ratio and considers whether there is sufficient supernatant on top of the saturated solids such that gas-bearing solids have the potential energy required to break up the material and release gas. Tanks that are not waste group C tanks and that have an energy ratio < 3.0 do not have sufficient potential energy to break up material and release gas and are assigned to waste group B. These tanks are considered to represent a potential induced flammable gas release hazard, but no spontaneous buoyant displacement flammable gas release hazard. Tanks that are not waste group C tanks and have an energy ratio {ge} 3.0, but that pass the third criterion (buoyancy ratio < 1.0, see below) are also assigned to waste group B. Even though the designation as

  2. METHODOLOGY AND CALCULATIONS FOR THE ASSIGNMENT OF WASTE GROUPS FOR THE LARGE UNDERGROUND WASTE STORAGE TANKS AT THE HANFORD SITE

    Energy Technology Data Exchange (ETDEWEB)

    FOWLER KD

    2007-12-27

    This document categorizes each of the large waste storage tanks into one of several categories based on each tank's waste characteristics. These waste group assignments reflect a tank's propensity to retain a significant volume of flammable gases and the potential of the waste to release retained gas by a buoyant displacement event. Revision 7 is the annual update of the calculations of the flammable gas Waste Groups for DSTs and SSTs. The Hanford Site contains 177 large underground radioactive waste storage tanks (28 double-shell tanks and 149 single-shell tanks). These tanks are categorized into one of three waste groups (A, B, and C) based on their waste and tank characteristics. These waste group assignments reflect a tank's propensity to retain a significant volume of flammable gases and the potential of the waste to release retained gas by a buoyant displacement gas release event. Assignments of waste groups to the 177 double-shell tanks and single-shell tanks, as reported in this document, are based on a Monte Carlo analysis of three criteria. The first criterion is the headspace flammable gas concentration following release of retained gas. This criterion determines whether the tank contains sufficient retained gas such that the well-mixed headspace flammable gas concentration would reach 100% of the lower flammability limit if the entire tank's retained gas were released. If the volume of retained gas is not sufficient to reach 100% of the lower flammability limit, then flammable conditions cannot be reached and the tank is classified as a waste group C tank independent of the method the gas is released. The second criterion is the energy ratio and considers whether there is sufficient supernatant on top of the saturated solids such that gas-bearing solids have the potential energy required to break up the material and release gas. Tanks that are not waste group C tanks and that have an energy ratio < 3.0 do not have sufficient

  3. CHINA'S LNG BUSINESS BOOMS

    Institute of Scientific and Technical Information of China (English)

    Xu Bo

    2006-01-01

    @@ Liquefied Natural Gas (LNG) is a low-temperature liquid mixture (-162℃) obtained by cooling and liquefaction of natural gas after deacidification and dehydration. In recent years, along with the surging global demand for energy and the drop of LNG cost, demand for LNG has been rising steadily. The primary underlying causes of that are the reduction of cost, the improvement of ship transportation and the changes in the form of trade. The tightening energy bottleneck brought by the rapid growth of China's economy might be well addressed by the active development of LNG industry, which can also help diversify the energy resources and facilitate the protection of environment.

  4. Review of Analytes of Concern and Sample Methods for Closure of DOE High Level Waste Storage Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Thomas Russell

    2002-08-01

    Sampling residual waste after tank cleaning and analysis for analytes of concern to support closure and cleaning targets of large underground tanks used for storage of legacy high level radioactive waste (HLW) at Department of Energy (DOE) sites has been underway since about 1995. The DOE Tanks Focus Area (TFA) has been working with DOE tank sites to develop new sampling plans, and sampling methods for assessment of residual waste inventories. This paper discusses regulatory analytes of concern, sampling plans, and sampling methods that support closure and cleaning target activities for large storage tanks at the Hanford Site, the Savannah River Site (SRS), the Idaho National Engineering and Environmental Laboratory (INEEL), and the West Valley Demonstration Project (WVDP).

  5. Review of Analytes of Concern and Sample Methods for Closure of DOE High Level Waste Storage Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, T.R.

    2002-05-06

    Sampling residual waste after tank cleaning and analysis for analytes of concern to support closure and cleaning targets of large underground tanks used for storage of legacy high level radioactive waste (HLW) at Department of Energy (DOE) sites has been underway since about 1995. The DOE Tanks Focus Area (TFA) has been working with DOE tank sites to develop new sampling plans, and sampling methods for assessment of residual waste inventories. This paper discusses regulatory analytes of concern, sampling plans, and sampling methods that support closure and cleaning target activities for large storage tanks at the Hanford Site, the Savannah River Site (SRS), the Idaho National Engineering and Environmental Laboratory (INEEL), and the West Valley Demonstration Project (WVDP).

  6. 影响LNG储罐无损检测准确性的因素分析%Analysis on the Factors of Affecting NDT Accuracy to LNG Store Tank

    Institute of Scientific and Technical Information of China (English)

    张辉宇; 谢建桥

    2015-01-01

    Aiming at the problems existed in 100%X-ray detection for the welded joints of the inner tank material (06Ni9DR)of China domestic LNG store tank, it analyzed the factors of affecting NDT accuracy in this article, the results indicated the weld reinforcement, intensifying screen thickness and other parameters all affect the film blackness , and the improper operation of scattered rays and darkroom processing also can affect the evaluation result accuracy. Only the film blackness, sensitivity, fog density and other technical parameters of radiographic detection reach standard requirements, the NDT for material defects can be completed, and obtained accurate evaluation results.%针对国内LNG储罐内罐材料(06Ni9DR)焊接接头进行100%X射线检测时存在的问题,分析了影响无损检测准确性的因素。分析结果表明,焊缝余高、增感屏厚度等参数都会影响底片的黑度,散射线和暗室处理操作不当也会影响评定结果的准确性。只有射线检测拍出的底片黑度、灵敏度、灰雾度等技术指标达到标准的要求,才能完成对材料缺陷的无损检测,得到准确的检测评定结果。

  7. Zero Boil-Off Methods for Large Scale Liquid Hydrogen Tanks Using Integrated Refrigeration and Storage

    Science.gov (United States)

    Notardonato, W. U.; Swanger, A. M.; Fesmire, J. E.; Jumper, K. M.; Johnson, W. L.; Tomsik, T. M.

    2017-01-01

    NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multi-layer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

  8. Cryograb: A Novel Approach to the Retrieval of Waste from Underground Storage Tanks - 13501

    Energy Technology Data Exchange (ETDEWEB)

    O' Brien, Luke; Baker, Stephen; Bowen, Bob [UK National Nuclear Laboratory, Chadwick House, Warrington (United Kingdom); Mallick, Pramod; Smith, Gary [US Department of Energy (United States); King, Bill [Savannah River National Laboratory (United States); Judd, Laurie [NuVision Engineering (United States)

    2013-07-01

    The UK's National Nuclear Laboratory (NNL) is investigating the use of cryogenic technology for the recovery of nuclear waste. Cryograb, freezing the waste on a 'cryo-head' and then retrieves it as a single mass which can then be treated or stabilized as necessary. The technology has a number of benefits over other retrieval approaches in that it minimizes sludge disturbance thereby reducing effluent arising and it can be used to de-water, and thereby reduce the volume of waste. The technology has been successfully deployed for a variety of nuclear and non-nuclear waste recovery operations. The application of Cryograb for the recovery of waste from US underground storage tanks is being explored through a US DOE International Technology Transfer and Demonstration programme. A sample deployment being considered involves the recovery of residual mounds of sludge material from waste storage tanks at Savannah River. Operational constraints and success criteria were agreed prior to the completion of a process down selection exercise which specified the preferred configuration of the cryo-head and supporting plant. Subsequent process modeling identified retrieval rates and temperature gradients through the waste and tank infrastructure. The work, which has been delivered in partnership with US DOE, SRNL, NuVision Engineering and Frigeo AB has demonstrated the technical feasibility of the approach (to TRL 2) and has resulted in the allocation of additional funding from DOE to take the programme to bench and cold pilot-scale trials. (authors)

  9. Risk assessment of Kermanshah gas storage tanks by energy trace and barrier analysis (2014

    Directory of Open Access Journals (Sweden)

    M. Ghanbari Kakavandi

    2016-12-01

    Full Text Available Background: Despite the cost and millions loss of life due to industrial accidents, often are preventable through risk assessment methods and control measures. Objective: To assess the safety of gas storage tanks in Kermanshah oil refinery by Energy Trace and Barrier Analysis (ETBA. Methods: This case-descriptive study was conducted in gas storage tanks of Kermanshah oil refinery. Energy checklist was used for identification of energy types. Energy flows were tracked and then, management and administrative procedures, and personal protective equipment were considered as safeguard. Exposed and vulnerable targets are also specified. Preliminary levels of risks were determined by combination of severity and likelihood. After suggestion of corrective action for unacceptable risks, risk assessment took place again. Identified risks were expressed using descriptive statistics such as frequency and percentage. Findings: Overall, 74 risks and 121 dangerous energies were identified. Of these, 25 risks were unacceptable, 46 were low risk, and 3 were acceptable risk with revised. Frequency of risks related to electric power was 20, and followed by risk of displacement- pressure-volume, potential and chemical energies, with frequencies of 13, 12 and 9, respectively. Conclusion: Given the environmental and protection conditions of the tanks, in addition, the high percentage of some of the damaging risks in this industry, use of appropriate control measures to prevention the event of future disasters will be inevitable.

  10. Treatment, storage, and disposal alternatives for the gunite and associated tanks at the Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    DePew, R.E.; Rickett, K. [Advanced Systems Technology, Inc., Oak Ridge, TN (United States); Redus, K.S. [MACTEC, Oak Ridge, TN (United States); DuMont, S.P. [Hazardous and Medical Waste Services, Inc. (United States); Lewis, B.E.; DePaoli, S.M.; Van Hoesen, S.D. Jr. [Oak Ridge National Lab., TN (United States)

    1996-05-01

    The gunite and associated tanks (GAAT) are inactive, liquid low-level waste tanks located in and around the North and South Tank Farms at Oak Ridge National Laboratory. These underground tanks are the subject of an ongoing treatability study that will determine the best remediation alternatives for the tanks. As part of the treatability study, an assessment of viable treatment, storage, and disposal (TSD) alternatives has been conducted. The report summarizes relevant waste characterization data and statistics obtained to date. The report describes screening and evaluation criteria for evaluating TSD options. Individual options that pass the screening criteria are described in some detail. Order-or-magnitude cost estimates are presented for each of the TSD system alternatives. All alternatives are compared to the baseline approach of pumping all of the GAAT sludge and supernate to the Melton Valley Storage Tank (MVST) facility for eventual TSD along with the existing MOST waste. Four TSD systems are identified as alternatives to the baseline approach. The baseline is the most expensive of the five identified alternatives. The least expensive alternative is in-situ grouting of all GAAT sludge followed by in-situ disposal. The other alternatives are: (1) ex-situ grouting with on-site storage and disposal at Nevada Test Site (NTS); (2) ex-situ grouting with on-site storage and disposal at NTS and the Waste Isolation Pilot Plant (WIPP); and (3) ex-situ vitrification with on-site storage and disposal at NTS and WIPP.

  11. LNG Safety Assessment Evaluation Methods

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Angela Christine [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-05-01

    Sandia National Laboratories evaluated published safety assessment methods across a variety of industries including Liquefied Natural Gas (LNG), hydrogen, land and marine transportation, as well as the US Department of Defense (DOD). All the methods were evaluated for their potential applicability for use in the LNG railroad application. After reviewing the documents included in this report, as well as others not included because of repetition, the Department of Energy (DOE) Hydrogen Safety Plan Checklist is most suitable to be adapted to the LNG railroad application. This report was developed to survey industries related to rail transportation for methodologies and tools that can be used by the FRA to review and evaluate safety assessments submitted by the railroad industry as a part of their implementation plans for liquefied or compressed natural gas storage ( on-board or tender) and engine fueling delivery systems. The main sections of this report provide an overview of various methods found during this survey. In most cases, the reference document is quoted directly. The final section provides discussion and a recommendation for the most appropriate methodology that will allow efficient and consistent evaluations to be made. The DOE Hydrogen Safety Plan Checklist was then revised to adapt it as a methodology for the Federal Railroad Administration’s use in evaluating safety plans submitted by the railroad industry.

  12. Methane emissions from sugarcane vinasse storage and transportation systems: Comparison between open channels and tanks

    Science.gov (United States)

    Oliveira, Bruna Gonçalves; Carvalho, João Luís Nunes; Chagas, Mateus Ferreira; Cerri, Carlos Eduardo Pellegrino; Cerri, Carlos Clemente; Feigl, Brigitte Josefine

    2017-06-01

    Over the last few years the brazilian sugarcane sector has produced an average of 23.5 million liters of ethanol annually. This scale of production generates large amounts of vinasse, which depending on the manner that is disposed, can result significant greenhouse gas emissions. This study aimed to quantify the methane (CH4) emissions associated with the two most widespread systems of vinasse storage and transportation used in Brazil; open channel and those comprising of tanks and pipes. Additionally, a laboratory incubation study was performed with the aim of isolating the effects of vinasse, sediment and the interaction between these factors on CH4 emissions. We observed significant differences in CH4 emissions between the sampling points along the channels during both years of evaluation (2012-2013). In the channel system, around 80% of CH4 emissions were recorded from uncoated sections. Overall, the average CH4 emission intensity was 1.36 kg CO2eq m-3 of vinasse transported in open channels, which was 620 times higher than vinasse transported through a system of tanks and closed pipes. The laboratory incubation corroborated field results, suggesting that vinasse alone does not contribute significant emissions of CH4. Higher CH4 emissions were observed when vinasse and sediment were incubated together. In summary, our findings demonstrate that CH4 emissions originate through the anaerobic decomposition of organic material deposited on the bottom of channels and tanks. The adoption of coated channels as a substitute to uncoated channels offers the potential for an effective and affordable means of reducing CH4 emissions. Ultimately, the modernization of vinasse storage and transportation systems through the adoption of tank and closed pipe systems will provide an effective strategy for mitigating CH4 emissions generated during the disposal phase of the sugarcane ethanol production process.

  13. The safe removal of frozen air from the annulus of an LH2 storage tank

    Science.gov (United States)

    Krenn, A.; Starr, S.; Youngquist, R.; Nurge, M.; Sass, J.; Fesmire, J.; Cariker, C.; Bhattacharya, A.

    2015-12-01

    Large Liquid Hydrogen (LH2) storage tanks are vital infrastructure for NASA. Eventually, air may leak into the evacuated and perlite filled annular region of these tanks. Although the vacuum level is monitored in this region, the extremely cold temperature causes all but the helium and neon constituents of air to freeze. A small, often unnoticeable pressure rise is the result. As the leak persists, the quantity of frozen air increases, as does the thermal conductivity of the insulation system. Consequently, a notable increase in commodity boil-off is often the first indicator of an air leak. Severe damage can result from normal draining of the tank. The warming air will sublimate which will cause a pressure rise in the annulus. When the pressure increases above the triple point, the frozen air will begin to melt and migrate downward. Collection of liquid air on the carbon steel outer shell may chill it below its ductility range, resulting in fracture. In order to avoid a structural failure, as described above, a method for the safe removal of frozen air is needed. A thermal model of the storage tank has been created using SINDA/FLUINT modelling software. Experimental work is progressing in an attempt to characterize the thermal conductivity of a perlite/frozen nitrogen mixture. A statistical mechanics model is being developed in parallel for comparison to experimental work. The thermal model will be updated using the experimental/statistical mechanical data, and used to simulate potential removal scenarios. This paper will address methodologies and analysis techniques for evaluation of two proposed air removal methods.

  14. Risk Based Inspection Methodology and Software Applied to Atmospheric Storage Tanks

    Science.gov (United States)

    Topalis, P.; Korneliussen, G.; Hermanrud, J.; Steo, Y.

    2012-05-01

    A new risk-based inspection (RBI) methodology and software is presented in this paper. The objective of this work is to allow management of the inspections of atmospheric storage tanks in the most efficient way, while, at the same time, accident risks are minimized. The software has been built on the new risk framework architecture, a generic platform facilitating efficient and integrated development of software applications using risk models. The framework includes a library of risk models and the user interface is automatically produced on the basis of editable schemas. This risk-framework-based RBI tool has been applied in the context of RBI for above-ground atmospheric storage tanks (AST) but it has been designed with the objective of being generic enough to allow extension to the process plants in general. This RBI methodology is an evolution of an approach and mathematical models developed for Det Norske Veritas (DNV) and the American Petroleum Institute (API). The methodology assesses damage mechanism potential, degradation rates, probability of failure (PoF), consequence of failure (CoF) in terms of environmental damage and financial loss, risk and inspection intervals and techniques. The scope includes assessment of the tank floor for soil-side external corrosion and product-side internal corrosion and the tank shell courses for atmospheric corrosion and internal thinning. It also includes preliminary assessment for brittle fracture and cracking. The data are structured according to an asset hierarchy including Plant, Production Unit, Process Unit, Tag, Part and Inspection levels and the data are inherited / defaulted seamlessly from a higher hierarchy level to a lower level. The user interface includes synchronized hierarchy tree browsing, dynamic editor and grid-view editing and active reports with drill-in capability.

  15. The Safe Removal of Frozen Air from the Annulus of an LH2 Storage Tank

    Science.gov (United States)

    Krenn, A.; Starr, S.; Youngquist, R.; Nurge, M.; Sass, J.; Fesmire, J.; Cariker, C.; Bhattacharya, A.

    2015-01-01

    Large Liquid Hydrogen (LH2) storage tanks are vital infrastructure for NASA. Eventually, air may leak into the evacuated and perlite filled annular region of these tanks. Although the vacuum level is monitored in this region, the extremely cold temperature causes all but the helium and neon constituents of air to freeze. A small, often unnoticeable pressure rise is the result. As the leak persists, the quantity of frozen air increases, as does the thermal conductivity of the insulation system. Consequently, a notable increase in commodity boil-off is often the first indicator of an air leak. Severe damage can result from normal draining of the tank. The warming air will sublimate which will cause a pressure rise in the annulus. When the pressure increases above the triple point, the frozen air will begin to melt and migrate downward. Collection of liquid air on the carbon steel outer shell may chill it below its ductility range, resulting in fracture. In order to avoid a structural failure, as described above, a method for the safe removal of frozen air is needed. A thermal model of the storage tank has been created using SINDA/FLUINT modeling software. Experimental work is progressing in an attempt to characterize the thermal conductivity of a perlite/frozen nitrogen mixture. A statistical mechanics model is being developed in parallel for comparison to experimental work. The thermal model will be updated using the experimental/statistical mechanical data, and used to simulate potential removal scenarios. This paper will address methodologies and analysis techniques for evaluation of two proposed air removal methods.

  16. Results Of Routine Strip Effluent Hold Tank, Decontaminated Salt Solution Hold Tank, Caustic Wash Tank And Caustic Storage Tank Samples From Modular Caustic-Side Solvent Extraction Unit During Macrobatch 6 Operations

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B.

    2014-01-02

    Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Caustic Storage Tank (CST) samples from the Interim Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 6 have been analyzed for 238Pu, 90Sr, 137Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The Pu, Sr, and Cs results from the current Macrobatch 6 samples are similar to those from comparable samples in previous Macrobatch 5. In addition the SEHT and DSSHT heel samples (i.e. ‘preliminary’) have been analyzed and reported to meet NGS Demonstration Plan requirements. From a bulk chemical point of view, the ICPES results do not vary considerably between this and the previous samples. The titanium results in the DSSHT samples continue to indicate the presence of Ti, when the feed material does not have detectable levels. This most likely indicates that leaching of Ti from MST has increased in ARP at the higher free hydroxide concentrations in the current feed.

  17. Standard practice for examination of liquid-Filled atmospheric and Low-pressure metal storage tanks using acoustic emission

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice covers guidelines for acoustic emission (AE) examinations of new and in-service aboveground storage tanks of the type used for storage of liquids. 1.2 This practice will detect acoustic emission in areas of sensor coverage that are stressed during the course of the examination. For flat-bottom tanks these areas will generally include the sidewalls (and roof if pressure is applied above the liquid level). The examination may not detect flaws on the bottom of flat-bottom tanks unless sensors are located on the bottom. 1.3 This practice may require that the tank experience a load that is greater than that encountered in normal use. The normal contents of the tank can usually be used for applying this load. 1.4 This practice is not valid for tanks that will be operated at a pressure greater than the examination pressure. 1.5 It is not necessary to drain or clean the tank before performing this examination. 1.6 This practice applies to tanks made of carbon steel, stainless steel, aluminum and oth...

  18. Transient Thermal Behavior of a Vertical Solar Storage Tank with a Mantle Heat Exchanger During No-Flow Operation

    Directory of Open Access Journals (Sweden)

    A. Barzegar

    2009-01-01

    Full Text Available Transient thermal behavior of a vertical storage tank of a domestic solar heating system with a mantle heat exchanger has been investigated numerically in the charging mode. It is assumed that the tank is initially filled with uniform cold water. At an instant of time, the hot fluid from collector outlet is uniformly injected in the upper section of the mantle heat exchanger and after heat transfer with the fluid inside the tank, withdrawn from the bottom part of the heat exchanger. The conservation equations in the cylindrical coordinate and in axis-symmetric condition have been used according to the geometry under investigation. Governing equations have been discretized by employing the finite volume method and the SIMPLER algorithm has been used for coupling between momentum and pressure equations. The Low Reynolds Number (LRN k −ω model is utilized for treating turbulence in the fluid. First, the transient thermal behavior of heat storage tank and the process of formation of thermal stratification in the heat storage tank were investigated. Then, the influence of Rayleigh number in the heat storage tank, Reynolds number in the mantle heat exchanger and vertical positioning of mantle on the flow and thermal fields and the formation of the thermal stratification was investigated. It is found that for higher values of Rayleigh number, a more suitable thermal stratification is established inside the tank. Also it is noticed that increasing the incoming fluid velocity through the mantle heat exchanger causes a faster formation of the thermal stratification. A superior thermal performance was achieved when the mantle heat exchanger is positioned at the middle height of the storage tank.

  19. A risk management approach to double-shell tank waste volume versus storage capacity

    Energy Technology Data Exchange (ETDEWEB)

    Coles, G.A. [Westinghouse Hanford Co., Richland, WA (United States); Thurkow, T.J.; Fritz, R.L.; Nuhlestein, L.O.; Allen, M.R.; Stuart, R.J. [ARES Corp. (United States)

    1996-01-01

    A risk-based assessment of the overall waste volume versus double-shell tank storage capacity was conducted to develop fallback positions for projections where the waste volume was at a high risk of exceeding capacity. This study was initiated to provide that assessment. A working simulation model was the primary deliverable of this study. The model validates the approach and demonstrates that simulation analysis can provide a method of tracking uncertainties in available data, assessing probabilities, and serves as a tool to be used by management to determine the consequences of various off-normal occurrences.

  20. LNG - Status in Denmark. Technology and potential. Project report

    Energy Technology Data Exchange (ETDEWEB)

    Naeslund, M.

    2012-05-15

    The interest for LNG both on a small and a large scale is increasing worldwide. The experiences and knowledge on LNG is limited in Denmark. The Danish gas companies' Technical Management Group (TCG) has asked for a status report including a technology description and an evaluation of the potential in Denmark. A survey of primarily small-scale LNG technology is done in the report. The focus is motivated by the new areas of gas utilisation that become possible with small-scale LNG. Small-scale LNG in this study is defined as LNG stored and used at the application or in an isolated gas grid. The small-scale use of LNG has today an almost negligible share of the total LNG trade but offers interesting new applications for gas utilisation. LNG on a small scale can be used primarily as: 1) Ship fuel. 2) Truck fuel (heavy duty long distance). 3) Individual users not connected to the natural gas grid. 4) Backup for upgraded biogas to individual users and vehicle fleets. 5) Security of supply or supply enhancement of heavily loaded parts of the gas grid. 6) Small-scale storage and/or peak shaving. All but the first topics are natural uses for the current Danish gas distributors. LNG as ship fuel may engage other specialized LNG companies. The report contains a technical description of the parts in primarily small-scale LNG handling and operation. Liquefaction, transport, storage, engine technologies, gas quality and safety aspects related to LNG are covered. There seem to be two more or less separate paths for LNG in Denmark, onshore and off-shore use. These are not, apparently, sharing their experiences and knowledge. Rules and regulations are also different which may create some problems in the interface, for example ship bunkering. Further studies are suggested in the area of gas quality and engine technologies and adaptation of foreign guidelines for small-scale installations to Danish conditions. These guidelines ought to be based on international standards and

  1. Seismic design and evaluation guidelines for the Department of Energy high-level waste storage tanks and appurtenances

    Energy Technology Data Exchange (ETDEWEB)

    Bandyopadhyay, K.; Cornell, A.; Costantino, C.; Kennedy, R.; Miller, C.; Veletsos, A.

    1993-01-01

    This document provides guidelines for the design and evaluation of underground high-level waste storage tanks due to seismic loads. Attempts were made to reflect the knowledge acquired in the last two decades in the areas of defining the ground motion and calculating hydrodynamic loads and dynamic soil pressures for underground tank structures. The application of the analysis approach is illustrated with an example. The guidelines are developed for specific design of underground storage tanks, namely double-shell structures. However, the methodology discussed is applicable for other types of tank structures as well. The application of these and of suitably adjusted versions of these concepts to other structural types will be addressed in a future version of this document.

  2. Analysis of constraints to the introduction of LNG plants in the Brazilian electric sector; Analise dos condicionantes para a introducao de plantas a GNL no setor eletrico brasileiro

    Energy Technology Data Exchange (ETDEWEB)

    Cortes, Tatiane Moraes Pestana

    2010-03-15

    This work aims analyze the constraints to the introduction of LNG in the Brazilian energy matrix. Therefore, considers the current regulatory framework and the investments recently made by PETROBRAS to acquire LNG in the international market in order to supply power plants in the country. In order to assess the current status of the LNG plants in the electricity sector, factors are analyzed in terms of the natural gas industry and electric power industry, such as: storage, LNG contracts, operating dispatch, LNG plants pricing and operational flexibility. Despite the increase in LNG international trade and the prospect of using this product in Brazil, there are some challenges for the effective use of LNG plants by Brazilian electric sector. Some of the challenges are the need to review the methodology of calculating the cost benefit of LNG power plants. Another important challenge is to examine the use of underground storage and its influence in the operating dispatch of LNG plants. (author)

  3. Development of a computer code to predict a ventilation requirement for an underground radioactive waste storage tank

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y.J.; Dalpiaz, E.L. [ICF Kaiser Hanford Co., Richland, WA (United States)

    1997-08-01

    Computer code, WTVFE (Waste Tank Ventilation Flow Evaluation), has been developed to evaluate the ventilation requirement for an underground storage tank for radioactive waste. Heat generated by the radioactive waste and mixing pumps in the tank is removed mainly through the ventilation system. The heat removal process by the ventilation system includes the evaporation of water from the waste and the heat transfer by natural convection from the waste surface. Also, a portion of the heat will be removed through the soil and the air circulating through the gap between the primary and secondary tanks. The heat loss caused by evaporation is modeled based on recent evaporation test results by the Westinghouse Hanford Company using a simulated small scale waste tank. Other heat transfer phenomena are evaluated based on well established conduction and convection heat transfer relationships. 10 refs., 3 tabs.

  4. Closure Report for Corrective Action Unit 121: Storage Tanks and Miscellaneous Sites, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Restoration

    2008-09-01

    Corrective Action Unit (CAU) 121 is identified in the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended February 2008) as Storage Tanks and Miscellaneous Sites. CAU 121 consists of the following three Corrective Action Sites (CASs) located in Area 12 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada: (1) CAS 12-01-01, Aboveground Storage Tank; (2) CAS 12-01-02, Aboveground Storage Tank; and (3) CAS 12-22-26, Drums; 2 AST's. CAU 121 closure activities were conducted according to the FFACO and the Streamlined Approach for Environmental Restoration Plan for CAU 121 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2007). Field work took place from February through September 2008. Samples were collected to determine the path forward to close each site. Closure activities were completed as defined in the plan based on sample analytical results and site conditions. No contaminants of concern (COCs) were present at CAS 12-01-01; therefore, no further action was chosen as the corrective action alternative. As a best management practice (BMP), the empty aboveground storage tank (AST) was removed and disposed as sanitary waste. At CAS 12-01-02, polychlorinated biphenyls (PCBs) were present above the preliminary action level (PAL) in the soil beneath the AST that could possibly have originated from the AST contents. Therefore, PCBs were considered COCs, and the site was clean closed by excavating and disposing of soil containing PCBs. Approximately 5 cubic yards (yd{sup 3}) of soil were excavated and disposed as petroleum hydrocarbon PCB remediation waste, and approximately 13 yd3 of soil were excavated and disposed as PCB remediation waste. Cleanup samples were collected to confirm that the remaining soil did not contain PCBs above the PAL. Other compounds detected in the soil above PALs (i.e., total petroleum hydrocarbons [TPH] and semi-volatile organic compounds [SVOCs

  5. METHODOLOGY & CALCULATIONS FOR THE ASSIGNMENT OF WASTE FOR THE LARGE UNDERGROUND WASTE STORAGE TANKS AT THE HANFORD SITE

    Energy Technology Data Exchange (ETDEWEB)

    TU, T.A.

    2007-01-04

    Waste stored within tank farm double-shell tanks (DST) and single-shell tanks (SST) generates flammable gas (principally hydrogen) to varying degrees depending on the type, amount, geometry, and condition of the waste. The waste generates hydrogen through the radiolysis of water and organic compounds, thermolytic decomposition of organic compounds, and corrosion of a tank's carbon steel walls. Radiolysis and thermolytic decomposition also generates ammonia. Nonflammable gases, which act as dilutents (such as nitrous oxide), are also produced. Additional flammable gases (e.g., methane) are generated by chemical reactions between various degradation products of organic chemicals present in the tanks. Volatile and semi-volatile organic chemicals in tanks also produce organic vapors. The generated gases in tank waste are either released continuously to the tank headspace or are retained in the waste matrix. Retained gas may be released in a spontaneous or induced gas release event (GRE) that can significantly increase the flammable gas concentration in the tank headspace as described in RPP-7771, Flammable Gas Safety Isme Resolution. Appendices A through I provide supporting information. The document categorizes each of the large waste storage tanks into one of several categories based on each tank's waste and characteristics. These waste group assignments reflect a tank's propensity to retain a significant volume of flammable gases and the potential of the waste to release retained gas by a buoyant displacement event. Revision 6 is the annual update of the flammable gas Waste Groups for DSTs and SSTs.

  6. Report of study group 3.3 ''LNG and LPG peak shaving and satellite plants''; Rapport du groupe d'etude 3.3 ''usines d'ecretement de pointes et stations satellites GNL et GPL''

    Energy Technology Data Exchange (ETDEWEB)

    Klein Nagelvoort, R.

    2000-07-01

    This report presents a world-wide overview of LNG and LPG Peak Shaving and Satellite Plants, compiled by the study group 3.3 of the International Gas Union. The scope of the work of the study group includes: - LPG peak shavers (LPG + air, N{sub 2}) in gas distribution networks; - LPG peak shavers for start-up and back-up fuel for LNG terminals and power stations; - LNG peak shavers for gas distribution networks; - Small-scale liquefaction plants for distribution to satellites and dedicated consumers (e.g. power generators, chemical plants, trucking companies etc.); - LNG peak shavers as back-up for large consumers; - Alternative liquefaction technologies for LNG and LPG (e.g. refrigeration cycles, supersonic expansion, thermo-acoustic designs); - Alternative storage tank designs for LNG and LPG. The report presents an overview of current installations world-wide and considers the prospects of technological developments with respect to equipment, remote operations and safety constraints. It also includes where possible a review of capital and operating costs, regulations, and an identification of opportunities and trends. The report collates the information available to the study group at the time of the writing, which may explain some heterogeneity in the document. (author)

  7. Fire performance of LNG carriers insulated with polystyrene foam.

    Science.gov (United States)

    Havens, Jerry; Venart, James

    2008-10-30

    Analysis of the response of a liquid-full Moss Sphere LNG tank insulated with polystyrene foam to an engulfing LNG fire indicates that current regulatory requirements for pressure relief capacity sufficient to prevent tank rupture are inadequate. The inadequacy of the current requirements stems primarily from two factors. Firstly, the area of the Moss Sphere protruding above what would be the nominal deck on a conventional carrier, which is protected only by a steel weather cover from exposure to heat from a tank-engulfing fire, is being underestimated. Secondly, aluminum foil-covered polystyrene foam insulation applied to the exterior of the LNG tank is protected above the deck only by the steel weather cover under which the insulation could begin to melt in as little as 1-3 min, and could completely liquefy in as few as 10 min. U.S. and International Regulations require that the insulations on the above-deck portion of tanks have approved fire proofing and stability under fire exposure. Polystyrene foam, as currently installed on LNG carriers, does not appear to meet these criteria. As a result of these findings, but giving no consideration to the significant potential for further damage if the polystyrene should burn, the boil-off rate is predicted to be an order-of-magnitude higher than provided for by current PRV sizing requirements.

  8. DOE underground storage tank waste remediation chemical processing hazards. Part I: Technology dictionary

    Energy Technology Data Exchange (ETDEWEB)

    DeMuth, S.F.

    1996-10-01

    This document has been prepared to aid in the development of Regulating guidelines for the Privatization of Hanford underground storage tank waste remediation. The document has been prepared it two parts to facilitate their preparation. Part II is the primary focus of this effort in that it describes the technical basis for established and potential chemical processing hazards associated with Underground Storage Tank (UST) nuclear waste remediation across the DOE complex. The established hazards involve those at Sites for which Safety Analysis Reviews (SARs) have already been prepared. Potential hazards are those involving technologies currently being developed for future applications. Part I of this document outlines the scope of Part II by briefly describing the established and potential technologies. In addition to providing the scope, Part I can be used as a technical introduction and bibliography for Regulatory personnel new to the UST waste remediation, and in particular Privatization effort. Part II of this document is not intended to provide examples of a SAR Hazards Analysis, but rather provide an intelligence gathering source for Regulatory personnel who must eventually evaluate the Privatization SAR Hazards Analysis.

  9. ADMINISTRATIVE AND ENGINEERING CONTROLS FOR THE OPERATION OF VENTILATION SYSTEMS FOR UNDERGROUND RADIOACTIVE WASTE STORAGE TANKS

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, B.; Hansen, A.

    2013-11-13

    Liquid radioactive wastes from the Savannah River Site are stored in large underground carbon steel tanks. The majority of the waste is confined in double shell tanks, which have a primary shell, where the waste is stored, and a secondary shell, which creates an annular region between the two shells, that provides secondary containment and leak detection capabilities should leakage from the primary shell occur. Each of the DST is equipped with a purge ventilation system for the interior of the primary shell and annulus ventilation system for the secondary containment. Administrative flammability controls require continuous ventilation to remove hydrogen gas and other vapors from the waste tanks while preventing the release of radionuclides to the atmosphere. Should a leak from the primary to the annulus occur, the annulus ventilation would also serve this purpose. The functionality of the annulus ventilation is necessary to preserve the structural integrity of the primary shell and the secondary. An administrative corrosion control program is in place to ensure integrity of the tank. Given the critical functions of the purge and annulus ventilation systems, engineering controls are also necessary to ensure that the systems remain robust. The system consists of components that are constructed of metal (e.g., steel, stainless steel, aluminum, copper, etc.) and/or polymeric (polypropylene, polyethylene, silicone, polyurethane, etc.) materials. The performance of these materials in anticipated service environments (e.g., normal waste storage, waste removal, etc.) was evaluated. The most aggressive vapor space environment occurs during chemical cleaning of the residual heels by utilizing oxalic acid. The presence of NO{sub x} and mercury in the vapors generated from the process could potentially accelerate the degradation of aluminum, carbon steel, and copper. Once identified, the most susceptible materials were either replaced and/or plans for discontinuing operations

  10. Large-volume heat storage tank made of GFK; Grosswaermespeichertank aus GFK

    Energy Technology Data Exchange (ETDEWEB)

    Buehl, J.; Schultheis, P. [Technische Univ. Ilmenau (Germany). Fachgebiet Technische Thermodynamik

    1998-12-31

    The Technical University of Ilmenau, the company Verbundwerkstoff- und Kunststoffanwendungstechnik Schoenbrunn, the Institute for Aerospace and Light-weight construction of Dresden University with its approved testing facilities for plastics and the Institute for Construction Engineering in Berlin and several other institutions co-operated since 1996 in developing a concept for a series of long-term heat storage tanks up to 6,000 cubic metres storage volume made of plastic (GFK components) with a combined thermal insulation. A model tank (sandwich body with proportional thermal insulation layer and selected mixed laminates) with a volume of 1.5 cubic metres was built and installed in November 1996. The tank has been continuously operated at various test levels. The experiment proves the longevity of the materials used. (orig.) [Deutsch] In Zusammenarbeit der TU Ilmenau mit der Fa. Verbundwerkstoff - und Kunststoffanwendungstechnik Schoenbrunn und dem Institut fuer Luftfahrttechnik und Leichtbau Dresden, seiner akkredierten Pruefstelle fuer Kunststoffe, in Abstimmung mit dem Institut fuer Bautechnik Berlin und weiteren Einrichtungen und Partnern wird seit 1996 an einem Konzept fuer eine Typenreihe Langzeitwaermespeicher bis vorerst 6.000 m{sup 3} Speichervolumen aus Kunststoff (GFK-Komponenten) und kombinierter integrierter thermischer Isolation gearbeitet. Im Vorfeld dieser Entwicklung wurde auf der Basis vorausgewaehlter Materialien und Kompositionen ein Musterspeicher (ein Sandwich - Modellkoerper mit proportionaler Waermedaemmschicht sowie ausgewaehlten Mischlaminaten) mit einem Speichervolumen von 1,5 m{sup 3} realisiert. Dieser Musterspeicher wurde im November 1996 installiert und wird seither kontinuierlich in den entsprechenden Erprobungsstufen betrieben. Der Nachweis der Langlebigkeit der eingesetzten Materialien wurde experimentell erbracht. (orig.)

  11. Qatari LNG starts flowing

    Energy Technology Data Exchange (ETDEWEB)

    Abi-Aad, Naji

    1997-02-01

    A Liquefied natural gas (LNG) project being undertaken by Qatargas (the Qatar Liquefied Gas Company) in Ras Laffan is described in this paper. The first of three planned liquefaction trains for the LNG plant has just been commissioned, with the second under construction and the third to be operational in 1999. Close cooperation with the Chiyoda contractors in Japan has ensured the success of the first part of the scheme. LNG is also to be exported back to Japan to fuel electricity generation plants. (UK)

  12. Qualitative Risk Assessment for an LNG Refueling Station and Review of Relevant Safety Issues

    Energy Technology Data Exchange (ETDEWEB)

    Siu, N.; Herring, J.S.; Cadwallader, L.; Reece, W.; Byers, J.

    1998-02-01

    This report is a qualitative assessment of the public and worker risk involved with the operation of a liquefied natural gas (LNG) vehicle refueling facility. This study includes facility maintenance and operations, tank truck deliveries, and end-use vehicle fueling; it does not treat the risks of LNG vehicles on roadways. Accident initiating events are identified by using a Master Logic Diagram, a Failure Modes and Effects Analysis, and historical operating experiences. The event trees were drawn to depict possible sequences of mitigating events following the initiating events. The phenomenology of LNG and other vehicle fuels is discussed to characterize the hazard posed by LNG usage. Based on the risk modeling and analysis, recommendations are given to improve the safety of LNG refueling stations in the areas of procedures and training, station design, and the dissemination of ``best practice`` information throughout the LNG community.

  13. A dispersion safety factor for LNG vapor clouds.

    Science.gov (United States)

    Vílchez, Juan A; Villafañe, Diana; Casal, Joaquim

    2013-02-15

    The growing importance of liquefied natural gas (LNG) to global energy demand has increased interest in the possible hazards associated with its storage and transportation. Concerning the event of an LNG spill, a study was performed on the relationship between the distance at which the lower flammability limit (LFL) concentration occurs and that corresponding to the visible contour of LNG vapor clouds. A parameter called the dispersion safety factor (DSF) has been defined as the ratio between these two lengths, and two expressions are proposed to estimate it. During an emergency, the DSF can be a helpful parameter to indicate the danger of cloud ignition and flash fire.

  14. Lower Colorado River GRP Leaking Underground Storage Tank Sites (Open), Nevada, 2012, Nevada Division of Environmental Protection Bureau of Corrective Actions

    Data.gov (United States)

    U.S. Environmental Protection Agency — The BCA layers are derived from a database for Federally Regulated Underground Storage Tanks (UST) and a database for Remediation and Leaking Underground Storage...

  15. Do-It-Yourself device for recovery of cryopreserved samples accidentally dropped into cryogenic storage tanks.

    Science.gov (United States)

    Mehta, Rohini; Baranova, Ancha; Birerdinc, Aybike

    2012-05-11

    Liquid nitrogen is colorless, odorless, extremely cold (-196 °C) liquid kept under pressure. It is commonly used as a cryogenic fluid for long term storage of biological materials such as blood, cells and tissues (1,2). The cryogenic nature of liquid nitrogen, while ideal for sample preservation, can cause rapid freezing of live tissues on contact - known as 'cryogenic burn' (2), which may lead to severe frostbite in persons closely involved in storage and retrieval of samples from Dewars. Additionally, as liquid nitrogen evaporates it reduces the oxygen concentration in the air and might cause asphyxia, especially in confined spaces (2). In laboratories, biological samples are often stored in cryovials or cryoboxes stacked in stainless steel racks within the Dewar tanks (1). These storage racks are provided with a long shaft to prevent boxes from slipping out from the racks and into the bottom of Dewars during routine handling. All too often, however, boxes or vials with precious samples slip out and sink to the bottom of liquid nitrogen filled tank. In such cases, samples could be tediously retrieved after transferring the liquid nitrogen into a spare container or discarding it. The boxes and vials can then be relatively safely recovered from emptied Dewar. However, the cryogenic nature of liquid nitrogen and its expansion rate makes sunken sample retrieval hazardous. It is commonly recommended by Safety Offices that sample retrieval be never carried out by a single person. Another alternative is to use commercially available cool grabbers or tongs to pull out the vials (3). However, limited visibility within the dark liquid filled Dewars poses a major limitation in their use. In this article, we describe the construction of a Cryotolerant DIY retrieval device, which makes sample retrieval from Dewar containing cryogenic fluids both safe and easy.

  16. Technical assessment of cryo-compressed hydrogen storage tank systems for automotive applications.

    Energy Technology Data Exchange (ETDEWEB)

    Ahluwalia, R. K.; Hua, T. Q.; Peng, J.-K.; Lasher, S.; McKenney, K.; Sinha, J.; Nuclear Engineering Division; TIAX LLC

    2010-03-03

    On-board and off-board performance and cost of cryo-compressed hydrogen storage has been assessed and compared to the DOE 2010, 2015 and ultimate targets for automotive applications. The Gen-3 prototype system of Lawrence Livermore National Laboratory was modeled to project the performance of a scaled-down 5.6-kg usable hydrogen storage system. The on-board performance of the system and high-volume manufacturing cost were determined for liquid hydrogen refueling with a single-flow nozzle and a pump that delivers 1.5 kg/min of liquid H{sub 2} to the insulated cryogenic tank capable of being pressurized to 272 atm (4000 psi). The off-board performance and cost of delivering liquid hydrogen were determined for two scenarios in which hydrogen is produced by central steam methane reforming (SMR) and by central electrolysis using electricity from renewable sources. The main conclusions from the assessment are that the cryo-compressed storage system has the potential of meeting the ultimate target for system gravimetric capacity and the 2015 target for system volumetric capacity (see Table I). The system compares favorably with targets for durability and operability although additional work is needed to understand failure modes for combined pressure and temperature cycling. The system may meet the targets for hydrogen loss during dormancy under certain conditions of minimum daily driving. The high-volume manufacturing cost is projected to be 2-4 times the current 2010 target of $4/kWh. For the reference conditions considered most applicable, the fuel cost for the SMR hydrogen production and liquid H{sub 2} delivery scenario is 60%-140% higher than the current target of $2-$3/gge while the well-to-tank efficiency is well short of the 60% target specified for off-board regenerable materials.

  17. SAVANNAH RIVER SITE INCIPIENT SLUDGE MIXING IN RADIOACTIVE LIQUID WASTE STORAGE TANKS DURING SALT SOLUTION BLENDING

    Energy Technology Data Exchange (ETDEWEB)

    Leishear, R.; Poirier, M.; Lee, S.; Steeper, T.; Fowley, M.; Parkinson, K.

    2011-01-12

    This paper is the second in a series of four publications to document ongoing pilot scale testing and computational fluid dynamics (CFD) modeling of mixing processes in 85 foot diameter, 1.3 million gallon, radioactive liquid waste, storage tanks at Savannah River Site (SRS). Homogeneous blending of salt solutions is required in waste tanks. Settled solids (i.e., sludge) are required to remain undisturbed on the bottom of waste tanks during blending. Suspension of sludge during blending may potentially release radiolytically generated hydrogen trapped in the sludge, which is a safety concern. The first paper (Leishear, et. al. [1]) presented pilot scale blending experiments of miscible fluids to provide initial design requirements for a full scale blending pump. Scaling techniques for an 8 foot diameter pilot scale tank were also justified in that work. This second paper describes the overall reasons to perform tests, and documents pilot scale experiments performed to investigate disturbance of sludge, using non-radioactive sludge simulants. A third paper will document pilot scale CFD modeling for comparison to experimental pilot scale test results for both blending tests and sludge disturbance tests. That paper will also describe full scale CFD results. The final paper will document additional blending test results for stratified layers in salt solutions, scale up techniques, final full scale pump design recommendations, and operational recommendations. Specifically, this paper documents a series of pilot scale tests, where sludge simulant disturbance due to a blending pump or transfer pump are investigated. A principle design requirement for a blending pump is UoD, where Uo is the pump discharge nozzle velocity, and D is the nozzle diameter. Pilot scale test results showed that sludge was undisturbed below UoD = 0.47 ft{sup 2}/s, and that below UoD = 0.58 ft{sup 2}/s minimal sludge disturbance was observed. If sludge is minimally disturbed, hydrogen will not be

  18. 40 CFR 63.11087 - What requirements must I meet for gasoline storage tanks if my facility is a bulk gasoline...

    Science.gov (United States)

    2010-07-01

    ... gasoline storage tanks if my facility is a bulk gasoline terminal, pipeline breakout station, or pipeline... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... § 63.11087 What requirements must I meet for gasoline storage tanks if my facility is a bulk...

  19. An International Survey of Electric Storage Tank Water Heater Efficiency and Standards

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Alissa; Lutz, James; McNeil, Michael A.; Covary, Theo

    2013-11-13

    Water heating is a main consumer of energy in households, especially in temperate and cold climates. In South Africa, where hot water is typically provided by electric resistance storage tank water heaters (geysers), water heating energy consumption exceeds cooking, refrigeration, and lighting to be the most consumptive single electric appliance in the home. A recent analysis for the Department of Trade and Industry (DTI) performed by the authors estimated that standing losses from electric geysers contributed over 1,000 kWh to the annual electricity bill for South African households that used them. In order to reduce this burden, the South African government is currently pursuing a programme of Energy Efficiency Standards and Labelling (EES&L) for electric appliances, including geysers. In addition, Eskom has a history of promoting heat pump water heaters (HPWH) through incentive programs, which can further reduce energy consumption. This paper provides a survey of international electric storage water heater test procedures and efficiency metrics which can serve as a reference for comparison with proposed geyser standards and ratings in South Africa. Additionally it provides a sample of efficiency technologies employed to improve the efficiency of electric storage water heaters, and outlines programs to promote adoption of improved efficiency. Finally, it surveys current programs used to promote HPWH and considers the potential for this technology to address peak demand more effectively than reduction of standby losses alone

  20. Revised cost savings estimate with uncertainty for enhanced sludge washing of underground storage tank waste

    Energy Technology Data Exchange (ETDEWEB)

    DeMuth, S.

    1998-09-01

    Enhanced Sludge Washing (ESW) has been selected to reduce the amount of sludge-based underground storage tank (UST) high-level waste at the Hanford site. During the past several years, studies have been conducted to determine the cost savings derived from the implementation of ESW. The tank waste inventory and ESW performance continues to be revised as characterization and development efforts advance. This study provides a new cost savings estimate based upon the most recent inventory and ESW performance revisions, and includes an estimate of the associated cost uncertainty. Whereas the author`s previous cost savings estimates for ESW were compared against no sludge washing, this study assumes the baseline to be simple water washing which more accurately reflects the retrieval activity along. The revised ESW cost savings estimate for all UST waste at Hanford is $6.1 B {+-} $1.3 B within 95% confidence. This is based upon capital and operating cost savings, but does not include development costs. The development costs are assumed negligible since they should be at least an order of magnitude less than the savings. The overall cost savings uncertainty was derived from process performance uncertainties and baseline remediation cost uncertainties, as determined by the author`s engineering judgment.

  1. Self-pressurization of a flightweight liquid hydrogen storage tank subjected to low heat flux

    Science.gov (United States)

    Hasan, M. M.; Lin, C. S.; Vandresar, N. T.

    1991-01-01

    Results are presented for an experimental investigation of self-pressurization and thermal stratification of a 4.89 cu m liquid hydrogen (LH2) storage tank subjected to low heat flux (0.35, 2.0, and 3.5 W/sq m) under normal gravity conditions. Tests were performed at fill levels of 83 to 84 percent (by volume). The LH2 tank was representative of future spacecraft tankage, having a low mass-to-volume ratio and high performance multilayer thermal insulation. Results show that the pressure rise rate and thermal stratification increase with increasing heat flux. At the lowest heat flux, the pressure rise rate is comparable to the homogenous rate, while at the highest heat flux, the rate is more than three times the homogeneous rate. It was found that initial conditions have a significant impact on the initial pressure rise rate. The quasi-steady pressure rise rates are nearly independent of the initial condition after an initial transient period has passed.

  2. Consequence modeling of fire on Methane storage tanks in a gas refinery

    Directory of Open Access Journals (Sweden)

    Sara Shahedi ali abadi

    2016-06-01

    Full Text Available Introduction: using fossil fuels, some hazards such as explosion and fire are probable. This study was aimed to consequence modeling of fire on Methane storage tanks in a gas refinery using analyzing the risk, and modeling and evaluating the related consequences. Method: Hazard analysis by PHA was used to choosing the worst-case scenario. Then, causes of the scenario were determined by FTA. After that, consequence modeling by the PHAST software was applied for the consequence analysis. Results: Based on some criteria, the fire of methane gas tank (V-100 was selected as the worst-case scenario at the refinery. The qualitative fault tree showed three factors including mechanical, process, and human failures contribute in gas leakage. The leakage size and weather conditions were effective on the distance of radiation. Using consequence modeling, thermal radiation was considered as the major outcome of the incident. Finally, for outcome evaluating, probit equations were used to quantify losses and the percentage of fatalities due to the methane gas leakage and fire occurrence. The maximum number of fatalities caused by fire was obtained 23 persons. Conclusions: In conclusion, the methane gas vessel in the refinery can be considered as the main center of hazard, therefore the implementation of the safety rules, eliminating mechanical failures, personal protection and education, and Effective measures to prevent and fighting of fire are proposed for decreasing the probable losses and fatalities.

  3. Aging mechanisms for concrete components of High-Level Waste storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Kassir, M.; Bandyopadhyay, K.; Bush, S.; Mather, B.; Shewmon, P.; Streicher, M.; Thompson, B.; van Rooyen, D.; Weeks, J.

    1995-05-01

    The age-related degradation mechanisms which affect the concrete and the reinforcing steel in the high-level waste (HLW) storage tanks art evaluated with respect to their potential significance to the continued performance of the concrete, and am classified into non-significant and potentially significant. The identified potentially significant degradation mechanisms include the effects of elevated temperature, freezing and thawing, leaching of calcium hydroxide, aggressive chemical attack, and corrosion of the reinforcing steel. To the extent that available knowledge permits, these mechanisms are generically evaluated and quantified so that site-specific plans may be developed to verify whether significant degradation has occurred in the concrete, and, if so, to formulate mitigating measures to avoid further deterioration and possibly repair the degradation or pursue other management options.

  4. Heat transfer in fuel oil storage tank at thermal power plants with local fuel heating

    Directory of Open Access Journals (Sweden)

    Kuznetsova Svetlana A.

    2015-01-01

    Full Text Available Results of mathematical modeling of the thermal control system in fuel oil storage, in the presence of heat source at the lower boundary of the region, in the framework of models of incompressible viscous fluid are presented. Solved the system of differential equations of non-stationary Navier-Stokes equations, the energy equation and the heat equation with appropriate initial and boundary conditions. Takes into account the processes of heat exchange region considered with the environment. A comparative analysis of the dependence of average temperatures of oil in the volume of the tank on the time calculated by the simplified (balanced method and obtained as a result of numerical simulation are performed.

  5. Corrosion damage at storage tanks for salt brine; Korrosionsschaeden an Lagertanks fuer Salzlake

    Energy Technology Data Exchange (ETDEWEB)

    Burkert, A.; Mietz, J. [Bundesanstalt fuer Materialforschung und -pruefung (BAM) Unter den Eichen 87, D-12205 Berlin (Germany)

    2003-02-01

    A tank made of stainless steel type X2CrNiMo17-12-2 for intermediate storage of salt brine for cheese production revealed significant pitting corrosion effects shortly after commissioning although comparable units have shown positive long-term behaviour. By means of electrochemical laboratory tests it could be demonstrated that the observed pitting corrosion was caused by the use of an oxidizing agent for desinfection purposes. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [German] An einem Tankbehaelter aus dem Werkstoff X2CrNiMo17-12-2, der zur Zwischenlagerung von Salzlake fuer die Kaeseherstellung dient, wurden trotz langjaehriger positiver Erfahrungen an vergleichbaren Anlagen bereits kurze Zeit nach der Inbetriebnahme Lochkorrosionserscheinungen festgestellt. Durch entsprechende elektrochemische Laboruntersuchungen konnte gezeigt werden, dass die vorgefundene Lochkorrosion durch den Einsatz eines Oxidationsmittels zu Desinfektionszwecken verursacht wurde. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  6. Leak prevention in underground storage tanks: A state-of-the-art survey

    Science.gov (United States)

    Gangadharan, A. C.; Narayanan, T. V.; Raghavan, R.; Amoruso, G.

    1987-05-01

    The overall objectives were to examine the structural design and operational practices associated with underground storage tank (UST) systems in the context of preventing leaks from such systems and identify areas for further research and development to advance the technology. Recommendations derived include: establishing a nations data base to provide information on failure rates and mechanisms and their correlation to design, engineering, installation, and operation practices and corrective actions; assessing the effectiveness of cathodic protection methods, their interaction with the environment, and the performance of retrofitting existing USTs; developing compatibility protocols for the selection of appropriate materials of construction and long-term protection; and developing methods to assess the life expectancy of both new and existing systems and to extend their useful life.

  7. Theoretical and experimental validation study on automotive air-conditioning based on heat pipe and LNG cold energy for LNG-fueled heavy vehicles

    Science.gov (United States)

    Deng, Dong; Cheng, Jiang-ping; Zhang, Sheng-chang; Ge, Fang-gen

    2017-08-01

    As a clean fuel, LNG has been used in heavy vehicles widely in China. Before reaching the engine for combustion, LNG store in a high vacuum multi-layer thermal insulation tank and need to be evaporated from its cryogenic state to natural gas. During the evaporation, the available cold energy of LNG has been calculated. The concept has been proposed that the separated type heat pipe technology is employed to utilize the available cold energy for automotive air-conditioning. The experiment has been conducted to validate the proposal. It is found that it is feasible to use the separated type heat pipe to convey the cold energy from LNG to automotive air-conditioning. And the cooling capacity of the automotive air-conditioning increase with the LNG consumption and air flow rate increasing.

  8. Theoretical and experimental validation study on automotive air-conditioning based on heat pipe and LNG cold energy for LNG-fueled heavy vehicles

    Science.gov (United States)

    Deng, Dong; Cheng, Jiang-ping; Zhang, Sheng-chang; Ge, Fang-gen

    2017-03-01

    As a clean fuel, LNG has been used in heavy vehicles widely in China. Before reaching the engine for combustion, LNG store in a high vacuum multi-layer thermal insulation tank and need to be evaporated from its cryogenic state to natural gas. During the evaporation, the available cold energy of LNG has been calculated. The concept has been proposed that the separated type heat pipe technology is employed to utilize the available cold energy for automotive air-conditioning. The experiment has been conducted to validate the proposal. It is found that it is feasible to use the separated type heat pipe to convey the cold energy from LNG to automotive air-conditioning. And the cooling capacity of the automotive air-conditioning increase with the LNG consumption and air flow rate increasing.

  9. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID)

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 3) presents the standards and requirements for the following sections: Safeguards and Security, Engineering Design, and Maintenance.

  10. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction.

  11. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 5

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 5) outlines the standards and requirements for the Fire Protection and Packaging and Transportation sections.

  12. High level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 6

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 6) outlines the standards and requirements for the sections on: Environmental Restoration and Waste Management, Research and Development and Experimental Activities, and Nuclear Safety.

  13. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 4

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 4) presents the standards and requirements for the following sections: Radiation Protection and Operations.

  14. High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 4

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    Radiation protection of personnel and the public is accomplished by establishing a well defined Radiation Protection Organization to ensure that appropriate controls on radioactive materials and radiation sources are implemented and documented. This Requirements Identification Document (RID) applies to the activities, personnel, structures, systems, components, and programs involved in executing the mission of the Tank Farms. The physical boundaries within which the requirements of this RID apply are the Single Shell Tank Farms, Double Shell Tank Farms, 242-A Evaporator-Crystallizer, 242-S, T Evaporators, Liquid Effluent Retention Facility (LERF), Purgewater Storage Facility (PWSF), and all interconnecting piping, valves, instrumentation, and controls. Also included is all piping, valves, instrumentation, and controls up to and including the most remote valve under Tank Farms control at any other Hanford Facility having an interconnection with Tank Farms. The boundary of the structures, systems, components, and programs to which this RID applies, is defined by those that are dedicated to and/or under the control of the Tank Farms Operations Department and are specifically implemented at the Tank Farms.

  15. The socio-ecohydrology of rainwater harvesting in India: understanding water storage and release dynamics at tank and catchment scales

    Science.gov (United States)

    Van Meter, K. J.; Basu, N. B.; McLaughlin, D. L.; Steiff, M.

    2015-11-01

    Rainwater harvesting (RWH), the small-scale collection and storage of runoff for irrigated agriculture, is recognized as a sustainable strategy for ensuring food security, especially in monsoonal landscapes in the developing world. In south India, these strategies have been used for millennia to mitigate problems of water scarcity. However, in the past 100 years many traditional RWH systems have fallen into disrepair due to increasing dependence on groundwater. This dependence has contributed to an accelerated decline in groundwater resources, which has in turn led to increased efforts at the state and national levels to revive older RWH systems. Critical to the success of such efforts is an improved understanding of how these ancient systems function in contemporary landscapes with extensive groundwater pumping and shifted climatic regimes. Knowledge is especially lacking regarding the water-exchange dynamics of these RWH "tanks" at tank and catchment scales, and how these exchanges regulate tank performance and catchment water balances. Here, we use fine-scale water-level variation to quantify daily fluxes of groundwater, evapotranspiration (ET), and sluice outflows in four tanks over the 2013 northeast monsoon season in a tank cascade that covers a catchment area of 28 km2. At the tank scale, our results indicate that groundwater recharge and irrigation outflows comprise the largest fractions of the tank water budget, with ET accounting for only 13-22 % of the outflows. At the scale of the cascade, we observe a distinct spatial pattern in groundwater-exchange dynamics, with the frequency and magnitude of groundwater inflows increasing down the cascade of tanks. The significant magnitude of return flows along the tank cascade leads to the most downgradient tank in the cascade having an outflow-to capacity ratio greater than 2. The presence of tanks in the landscape dramatically alters the catchment water balance, with runoff decreasing by nearly 75 %, and

  16. The socio-ecohydrology of rainwater harvesting in India: understanding water storage and release dynamics at tank and catchment scales

    Directory of Open Access Journals (Sweden)

    K. J. Van Meter

    2015-11-01

    Full Text Available Rainwater harvesting (RWH, the small-scale collection and storage of runoff for irrigated agriculture, is recognized as a sustainable strategy for ensuring food security, especially in monsoonal landscapes in the developing world. In south India, these strategies have been used for millennia to mitigate problems of water scarcity. However, in the past 100 years many traditional RWH systems have fallen into disrepair due to increasing dependence on groundwater. This dependence has contributed to an accelerated decline in groundwater resources, which has in turn led to increased efforts at the state and national levels to revive older RWH systems. Critical to the success of such efforts is an improved understanding of how these ancient systems function in contemporary landscapes with extensive groundwater pumping and shifted climatic regimes. Knowledge is especially lacking regarding the water-exchange dynamics of these RWH "tanks" at tank and catchment scales, and how these exchanges regulate tank performance and catchment water balances. Here, we use fine-scale water-level variation to quantify daily fluxes of groundwater, evapotranspiration (ET, and sluice outflows in four tanks over the 2013 northeast monsoon season in a tank cascade that covers a catchment area of 28 km2. At the tank scale, our results indicate that groundwater recharge and irrigation outflows comprise the largest fractions of the tank water budget, with ET accounting for only 13–22 % of the outflows. At the scale of the cascade, we observe a distinct spatial pattern in groundwater-exchange dynamics, with the frequency and magnitude of groundwater inflows increasing down the cascade of tanks. The significant magnitude of return flows along the tank cascade leads to the most downgradient tank in the cascade having an outflow-to capacity ratio greater than 2. The presence of tanks in the landscape dramatically alters the catchment water balance, with runoff decreasing by

  17. Design and analysis of a multi-cell subscale tank for liquid hydrogen storage

    NARCIS (Netherlands)

    Tapeinos, I.; Koussios, S.; Groves, R.M.

    2015-01-01

    This paper outlines the structural performance of a conformable pressurizable tank consisting of intersecting spherical shells (multi-cell tank). Multi-cell tanks outrival conventional multiple cylindrical tanks in volumetric efficiency when required to fit in a rectangular envelope in the

  18. 液化天然气储罐火灾爆炸事故的定量分析%Quantitative analysis on fire and explosion accident of LNG tank

    Institute of Scientific and Technical Information of China (English)

    闫家伟; 宋文华; 董影超; 谢飞

    2011-01-01

    In this paper the basic situation of a gas station was introduced. One 3000 m3 spherical tank of natural gas tank area was analyzed by American DOW chemical index evaluation method. The evaluation result showed that the danger index for fire explosion was 149. 1 and its risk level was larger. During the storage process, if the gas in storage tank fired and exploded, the equipments, facilities and personnel within the radius 38. 17m and area 4574. 82 m2 would be destroyed and damaged. This case would cause great economic losses, and the maximum property damage was 0. 66A million yuan. Because some security measures had been taken to this unit for safety compensation, the loss of accidents was effectively reduced. It provided reference for opreating managers to completely understand the risk status of the tank field. The indicators provided a basis for natural gas tank area planning management, accident prevention and emergency rescue.%介绍了某天然气站的基本情况,利用道化学指数评价法,对该站储罐区的1个3000m3球罐进行风险评价,评价结果表明:该罐火灾爆炸指数为149.1,危险等级是较大.一旦罐内天然气在储存过程中发生火灾、爆炸,将使半径38.17m内,面积4574.82m2内的设备、设施受到损害,最大可能财产损失为0.66A万元.由于罐区采取了一些安全措施对储罐安全进行补偿,有效地降低了事故损失.为操作管理者更加全面地了解整个罐区的风险状况提供参考,有利于天然气储罐区的规划、管理及事故预防等.

  19. Fire suppression system of a small-scale LNG loading facility at PT Badak NGL

    Science.gov (United States)

    Yustiarza, Farhan Hilmyawan

    2017-03-01

    LNG progressively become favorable energy to replace oil-based fuel due to lower cost and more environment-friendly. In order to support an emerging LNG demands in Kalimantan, PT Badak NGL, one of the leading LNG Company in the world, develops the land-transported LNG loading facility. This facility performs loading the LNG into a small-scale tank (ISO Tank) with 20 m3 capacities. Safety reviews over this facility were conducted. Based on these reviews, the LNG filling station requires supplemental safeguards, such as LNG spill containment and firefighting foam system besides firewater system and dry chemical system. The spill containment provides holding LNG spill within the limits of plant property, while the high expansion foam system deals to minimize the vaporization rate to prevent a fire incident. This paper mainly discusses designing of such supplemental safeguards. The requirement of the spill containment is 20 m3 (6.3 × 3.3 × 2.0) m and the foam system should be capable generating foam at least 40 m3/min.

  20. LNG Development Booms in China

    Institute of Scientific and Technical Information of China (English)

    Tao Decan Hanju

    2011-01-01

    @@ China's LNG imports were 6.769 million tons from January to September in 2010, 70.95% higher than the same period of 2009.42% was from Australia and 16% from Indonesia.LNG is now becoming a major gas source in China.Meanwhile, China is evolving into an important target market for major LNG producing countries.

  1. Comparison of biofilm formation and water quality when water from different sources was stored in large commercial water storage tanks.

    Science.gov (United States)

    van der Merwe, Venessa; Duvenage, Stacey; Korsten, Lise

    2013-03-01

    Rain-, ground- and municipal potable water were stored in low density polyethylene storage tanks for a period of 90 days to determine the effects of long-term storage on the deterioration in the microbial quality of the water. Total viable bacteria present in the stored water and the resultant biofilms were enumerated using heterotrophic plate counts. Polymerase chain reaction (PCR) and Colilert-18(®) tests were performed to determine if the faecal indicator bacteria Escherichia coli was present in the water and in the biofilm samples collected throughout the study. The municipal potable water at the start of the study was the only water source that conformed to the South African Water Quality Guidelines for Domestic Use. After 15 days of storage, this water source had deteriorated microbiologically to levels considered unfit for human consumption. E. coli was detected in the ground- and potable water and ground- and potable biofilms periodically, whereas it was detected in the rainwater and associated biofilms at every sampling point. Imperfections in the UV resistant inner lining of the tanks were shown to be ecological niches for microbial colonisation and biofilm development. The results from the current study confirmed that long-term storage can influence water quality and increase the number of microbial cells associated with biofilms on the interior surfaces of water storage tanks.

  2. Investigation and optimisation of heat storage tanks for low-flow SDHW systems[Solar Domestic Hot Water

    Energy Technology Data Exchange (ETDEWEB)

    Knudsen, Soeren

    2004-07-01

    This thesis, 'Investigation and optimisation of heat storage tanks for low-flow SDHW systems', describes a study of the heat transfer and flow structure in vertical mantle heat exchangers for low-flow Solar Domestic Hot Water (SDHW) systems. The heat storage is a key component in SDHW systems and the vertical mantle heat exchanger is one of the most promising heat storage designs for low-flow SDHW systems. The study was carried out using a combination of experimental and numerical methods. Thermal experiments of mantle heat exchangers with different mantle inlet designs showed that the mantle inlet port with advantage can be located a distance from the top of the mantle. Consequently, the mantle heat exchangers marketed today can be improved by changing the mantle inlet position. The heat transfer and flow structure in mantle heat exchangers are rather complex and the thermal experiments were followed by investigations by means of advanced experimental and numerical techniques such as Particle Image Velocimetry (PIV) and Computational Fluid Dynamics (CFD). Using a transparent glass mantle tank, experimental flow visualisation was carried out with a PIV system. The flow structures inside the mantle and inside the tank were visualised and then compared with the flow structures predicted by CFD-models. The investigations showed that the CFD-models were able to model the flow in the mantle and in the tank correctly. The CFD-models were also validated by means of thermal experiments with a steel mantle tank. With the verified CFD-models, a parameter analysis was carried out for differently designed mantle heat exchangers for different typical conditions to reveal how the mantle tank parameters influence the flow structure and heat transfer in mantle heat exchangers. The heat transfer in the mantle near the mantle inlet port showed to be in the mixed convection regime, and as the distance from the inlet increased, natural convection started to dominate. The

  3. Sampling and analysis of radioactive liquid wastes and sludges in the Melton Valley and evaporator facility storage tanks at ORNL

    Energy Technology Data Exchange (ETDEWEB)

    Sears, M.B.; Botts, J.L.; Ceo, R.N.; Ferrada, J.J.; Griest, W.H.; Keller, J.M.; Schenley, R.L.

    1990-09-01

    The sampling and analysis of the radioactive liquid wastes and sludges in the Melton Valley Storage Tanks (MVSTs), as well as two of the evaporator service facility storage tanks at ORNL, are described. Aqueous samples of the supernatant liquid and composite samples of the sludges were analyzed for major constituents, radionuclides, total organic carbon, and metals listed as hazardous under the Resource Conservation and Recovery Act (RCRA). Liquid samples from five tanks and sludge samples from three tanks were analyzed for organic compounds on the Environmental Protection Agency (EPA) Target Compound List. Estimates were made of the inventory of liquid and sludge phases in the tanks. Descriptions of the sampling and analytical activities and tabulations of the results are included. The report provides data in support of the design of the proposed Waste Handling and Packaging Plant, the Liquid Low-Level Waste Solidification Project, and research and development activities (R D) activities in developing waste management alternatives. 7 refs., 8 figs., 16 tabs.

  4. Finite Element Analysis of High Pressure Storage Tank%高压储气罐有限元分析

    Institute of Scientific and Technical Information of China (English)

    蔡毅; 田东兴; 马秋生

    2012-01-01

    本文以ANSYS软件为基础,对高压长圆柱形天然气储运罐进行变形分析、应力分析,得到了储气罐的应力分布状态,分析了在壁厚方向及沿着罐壁方向上的应力变化。所得结果和理论结果吻合。此基础上,完成了气罐模态分析,得到了气罐的各阶固有频率及振型。计算结果表明计算方法有效,为进一步设计高压气罐提供了理论依据。%In this paper, based on Ansys the deformation and stress for high pressure long cylindrical natural gas storage tank are anal- ysed. And obtain the stress distribution of the storage tank. The changes of stress are analysed in thickness direction and along the rigid wall. The results and theoretical results are accordance. On this basis, the modal analysis of tank is completed too. Obtained the tank various order natural frequency and vibration mode. The calculation results show that the method is effective and provide the theoreti- cal basis for high pressure tank design.

  5. Prediction of thermal hydraulic characteristics inside the storage tank of a horizontal condensation heat exchanger using MARS-KS

    Science.gov (United States)

    Shin, Byung Soo; Seul, Kwang Won; Do, Kyu Sik; Reactor system evaluation Team

    2012-11-01

    The performance of a horizontal condensation heat exchanger is determined by the condensation heat transfer inside the heat exchanger tubes, convective or boiling heat transfer outside the tubes and flow characteristics in the storage tank. The flow characteristics in the tank are important factors to determine the heat transfer rate outside the tubes. The objective of this work is to develop the method to predict the heat transfer rate outside the tubes properly using MARS-KS code. Two different results from MARS-KS were compared with simplified experimental results in other works to estimate the capacity of MARS-KS. One was by a typical 1D nodalization but another was by a 3D nodalization considering natural circulation in the storage tank. Then, to eliminate the effect of condensation heat transfer inside the tubes, the experimental results on temperature profiles were applied to the inside wall of tubes as boundary conditions. As the result, the 3-D nodalization model had good predictions with experimental results in regard of wall temperature, heat flux and heat transfer coefficients. It was also confirmed that the natural circulation flow was developed inside the storage tank.

  6. Effects of Material Choice on Biocide Loss in Orion Water Storage Tanks

    Science.gov (United States)

    Wallace, William T.; Castro-Wallace, Sarah L.; Kuo, C. K. Mike; Loh, Leslie J.; Hudson, Edgar; Gazda, Daniel B.; Lewis, John F.

    2016-01-01

    additional challenges when used in water storage tanks with ionic silver biocide.

  7. Effects of Material Choice on Biocide Loss in Orion Water Storage Tanks

    Science.gov (United States)

    Wallace, W. T.; Wallace, S. L.; Gazda, D. B.; Lewis, J. F.

    2016-01-01

    When preparing for long-duration spaceflight missions, maintaining a safe supply of potable water is of the utmost importance. One major aspect of that is ensuring that microbial growth is minimized. Historically, this challenge has been addressed through the use of biocides. When using biocides, the choice of materials for the storage containers is important, because surface reactions can reduce biocide concentrations below their effective range. In the water storage system baselined for the Orion vehicle, the primary wetted materials are stainless steel (316 L) and a titanium alloy (Ti6Al4V). Previous testing with these materials has shown that the biocide selected for use in the system (ionic silver) will plate out rapidly upon initial wetting of the system. One potential approach for maintaining an adequate biocide concentration is to spike the water supply with high levels of biocide in an attempt to passivate the surface. To evaluate this hypothesis, samples of the wetted materials were tested individually and together to determine the relative loss of biocide under representative surface area-to-volume ratios after 24 hours. Additionally, we have analyzed the efficacy of disinfecting a system containing these materials by measuring reductions in bacterial counts in the same test conditions. Preliminary results indicate that the use of titanium, either individually or in combination with stainless steel, can result in over 95% loss of biocide, while less than 5% is lost when using stainless steel. In bacterial testing, viable organisms were recovered from samples exposed to the titanium coupons after 24 hours. By comparison, no organisms were recovered from the test vessels containing only stainless steel. These results indicate that titanium, while possessing some favorable attributes, may pose additional challenges when used in water storage tanks with ionic silver biocide.

  8. Request for closure, underground storage tank 2130-U: Oak Ridge Y-12 Plant, Oak Ridge, Tennessee, Facility ID {number_sign}0-010117

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-01

    This document presents a summary of the activities and analytical data related to the removal of underground storage tank (UST) 2130-U, previously located at the Oak Ridge Y-12 Plant. Removal of this tank was conducted in accordance with Tennessee Department of Environment and Conservation (TDEC) regulation 1200-1-15 (1992). A completed copy of the State of Tennessee, Division of Underground Storage Tanks, Permanent Closure Report Form is included as Appendix A of this document Based on the information and data presented herein, the Oak Ridge Y-12 Plant requests permanent closure for the tank 2130-U site.

  9. Underground Storage Tanks, The dataset contains the locations of sites where Underground/Abovegroumd Storge Tanks are/were located., Published in 2011, 1:12000 (1in=1000ft) scale, Alabama Department of Environmental Management.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Underground Storage Tanks dataset, published at 1:12000 (1in=1000ft) scale, was produced all or in part from Field Survey/GPS information as of 2011. It is...

  10. Design Essentials of 80 m3 Diluted Acetaldehyde Storage Tank%浅谈80 m3稀乙醛储槽设计要点

    Institute of Scientific and Technical Information of China (English)

    白春山; 刘文元

    2009-01-01

    Combination 80 m3 thin acetaldehyde tank design, the paper focused on low-pressure tank-top cans bearing ring, tank walls, tank top and anchor set design and the method of calculating and comparing the general design of storage tanks were introduced.%结合80 m3稀乙醛储槽的设计,着重介绍低压储罐罐顶承压环、罐壁、罐顶以及锚栓设置的设计及其计算方法,并与一般储罐设计进行比较.

  11. Hydrodynamically induced loads on components submerged in high-level waste-storage tanks

    Science.gov (United States)

    Weiner, E. O.; Julyk, J. L.; Rezvani, M. A.

    1994-06-01

    This paper addresses the effects of added mass on components submerged in fluids. In particular, as new equipment is designed for installation in the double-shell waste-storage tanks at the Hanford Site near Richland, Washington, the equipment and the tank must be evaluated for the anticipated loads. Seismically induced loads combined with loadings from other sources must be considered during this evaluation. A literature review shows that, for components in fluids confined to a narrow annulus or without a free surface, drastic reductions in response to seismic excitation are predicted by two-dimensional analysis. This phenomenon has been supported by testing. The reductions are explained in terms of mass coupling and buoyancy effects. For equipment submerged in fluids having a free surface and large annulus, practice suggest that it is appropriate to lump the added-mass terms with the component to address the hydrodynamic effects adequately. As in the case of a narrow annulus, this practice will reduce the natural frequency of the submerged component, but generally will increase the loads. This paper presents the structural evaluations of submerged components using computer models that employ mock fluid elements that determine the appropriateness of considering fluid added-mass and buoyancy effects. The results indicate that if a free surface exists and the submerged component has a wide fluid annulus about it, then the added mass should be lumped with the model, and buoyancy effects are not significant. The component then may be considered to be in an air environment, and the stresses are calculated from the application of standard response spectrum procedures.

  12. 低温丙烯储罐的自动控制%Automatic Control for Cryogenic Propylene Storage Tank

    Institute of Scientific and Technical Information of China (English)

    张伟; 方留安

    2013-01-01

    Large cryogenic tank pressure is close to atmospheric pressure.The change of external environment easily causes change of tank pressure,and influences the safe operation of storage tank negatively.The storage tank is equipped with a set of DCS and a set of ESD.DCS and ESD are fully independent.Precision servo liquid level meter and tuning fork liquid level switch are used for tank level measurement,control and interlock.Flow balance method is used to detect leakage of propylene conveying pipeline.Temperature detection is uniformly distributed on the ceiling inner surface of tank,bottom inner surface and inner surface.Three pressure transmitters are used for tank pressure measurement,control and interlock.The results show the safe and reliable control and interlock system can not only guarantee safe operation of storage tank,but also can achieve good economie benefit.%大型低温储罐压力接近常压,环境变化极易引起储罐压力的变化,造成安全隐患.储罐装置控制系统和联锁系统采用独立的DCS和紧急停车系统(ESD);精度伺服液位计和音叉式液位开关用于储罐液位的测量、控制和联锁;采用流量平衡法检测丙烯输送管线的泄漏,温度检测均匀分布在储罐吊顶内表面、罐底内表面、罐壁内表面;采用3台压力变送器对储罐的压力进行测量、控制和联锁.应用表明:安全可靠的控制系统和联锁系统,既保障了储罐的安全运行又取得了良好的经济效益.

  13. LNG - emergency control

    Energy Technology Data Exchange (ETDEWEB)

    Berardinelli, Ricardo Porto; Correa, Kleber Macedo; Moura Filho, Nelson Barboza de; Fernandez, Carlos Antonio [TRANSPETRO, Rio de Janeiro, RJ (Brazil); Matos, Jose Eduardo Nogueira de [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The operation of liquefied natural gas (LNG) is pioneering within the PETROBRAS System. PETROBRAS Transporte - TRANSPETRO is going to operate two flexible LNG terminals, located in Ceara and Rio de Janeiro. In accordance with the Corporate Health, Safety and Environmental (HSE) Directive - Training, Education and Awareness, PETROBRAS Transporte S.A. - TRANSPETRO has prepared an action plan with the objective of ensuring the operational safety of the undertaking. Among other actions a training program for the emergency control of LNG will be inserted into the timetable. The above mentioned training program was held over a period of 20 hours, and was divided between theory and practice. In the theoretical part, the characteristics of the product, the history of accidents and the emergency response procedures were covered. In the practical part, 3000 gallons of LNG were utilized where the behavior of the product could be confirmed following a confined leak, thereby verifying the efficacy of the emergency control resources. The teaching process of the course was developed in the company through the preparation of specific procedures, emergency plans and the formation of internal instructors. (author)

  14. LNG annotated bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Bomelburg, H.J.; Counts, C.A.; Cowan, C.E.; Davis, W.E.; DeSteese, J.G.; Pelto, P.J.

    1982-09-01

    This document updates the bibliography published in Liquefied Gaseous Fuels Safety and Environmental Control Assessment Program: third status report (PNL-4172) and is a complete listing of literature reviewed and reported under the LNG Technical Surveillance Task. The bibliography is organized alphabetically by author.

  15. A novel method to design water spray cooling system to protect floating roof atmospheric storage tanks against fires

    Directory of Open Access Journals (Sweden)

    Iraj Alimohammadi

    2015-01-01

    Full Text Available Hydrocarbon bulk storage tank fires are not very common, but their protection is essential due to severe consequences of such fires. Water spray cooling system is one of the most effective ways to reduce damages to a tank from a fire. Many codes and standards set requirements and recommendations to maximize the efficiency of water spray cooling systems, but these are widely different and still various interpretations and methods are employed to design such systems. This article provides a brief introduction to some possible design methods of cooling systems for protection of storage tanks against external non-contacting fires and introduces a new method namely “Linear Density Method” and compares the results from this method to the “Average Method” which is currently in common practice. The average Method determines the flow rate for each spray nozzle by dividing the total water demand by the number of spray nozzles while the Linear Density Method determines the nozzle flow rate based on the actual flow over the surface to be protected. The configuration of the system includes a one million barrel crude oil floating roof tank to be protected and which is placed one half tank diameter from a similar adjacent tank with a full surface fire. Thermal radiation and hydraulics are modeled using DNV PHAST Version 6.53 and Sunrise PIPENET Version 1.5.0.2722 software respectively. Spray nozzles used in design are manufactured by Angus Fire and PNR Nozzles companies. Schedule 40 carbon steel pipe is used for piping. The results show that the cooling system using the Linear Density Method consumes 3.55% more water than the design using the average method assuming a uniform application rate of 4.1 liters per minute. Despite higher water consumption the design based on Linear Density Method alleviates the problems associated with the Average Method and provides better protection.

  16. Seismic design and evaluation guidelines for the Department of Energy High-Level Waste Storage Tanks and Appurtenances

    Energy Technology Data Exchange (ETDEWEB)

    Bandyopadhyay, K.; Cornell, A.; Costantino, C.; Kennedy, R.; Miller, C.; Veletsos, A.

    1995-10-01

    This document provides seismic design and evaluation guidelines for underground high-level waste storage tanks. The guidelines reflect the knowledge acquired in the last two decades in defining seismic ground motion and calculating hydrodynamic loads, dynamic soil pressures and other loads for underground tank structures, piping and equipment. The application of the guidelines is illustrated with examples. The guidelines are developed for a specific design of underground storage tanks, namely double-shell structures. However, the methodology discussed is applicable for other types of tank structures as well. The application of these and of suitably adjusted versions of these concepts to other structural types will be addressed in a future version of this document. The original version of this document was published in January 1993. Since then, additional studies have been performed in several areas and the results are included in this revision. Comments received from the users are also addressed. Fundamental concepts supporting the basic seismic criteria contained in the original version have since then been incorporated and published in DOE-STD-1020-94 and its technical basis documents. This information has been deleted in the current revision.

  17. Effect of interfacial turbulence and accommodation coefficient on CFD predictions of pressurization and pressure control in cryogenic storage tank

    Science.gov (United States)

    Kassemi, Mohammad; Kartuzova, Olga

    2016-03-01

    Pressurization and pressure control in cryogenic storage tanks are to a large extent affected by heat and mass transport across the liquid-vapor interface. These mechanisms are, in turn, controlled by the kinetics of the phase change process and the dynamics of the turbulent recirculating flows in the liquid and vapor phases. In this paper, the effects of accommodation coefficient and interfacial turbulence on tank pressurization and pressure control simulations are examined. Comparison between numerical predictions and ground-based measurements in two large liquid hydrogen tank experiments, performed in the K-site facility at NASA Glenn Research Center (GRC) and the Multi-purpose Hydrogen Test Bed (MHTB) facility at NASA Marshall Space Flight Center (MSFC), are used to show the impact of accommodation coefficient and interfacial and vapor phase turbulence on evolution of pressure and temperatures in the cryogenic storage tanks. In particular, the self-pressurization comparisons indicate that: (1) numerical predictions are essentially independent of the magnitude of the accommodation coefficient; and (2) surprisingly, laminar models sometimes provide results that are in better agreement with experimental self-pressurization rates, even in parametric ranges where the bulk flow is deemed fully turbulent. In this light, shortcomings of the present CFD models, especially, numerical treatments of interfacial mass transfer and turbulence, as coupled to the Volume-of-Fluid (VOF) interface capturing scheme, are underscored and discussed.

  18. Closure Report for Corrective Action Unit 124, Storage Tanks, Nevada Test Site, Nevada with Errata Sheet, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Alfred Wickline

    2008-01-01

    This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 124, Storage Tanks, Nevada Test Site (NTS), Nevada. This report complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996; as amended January 2007). This CR provides documentation and justification for the closure of CAU 124 without further corrective action. This justification is based on process knowledge and the results of the investigative activities conducted in accordance with the Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 124: Storage Tanks, Nevada Test Site, Nevada (NNSA/NSO, 2007). The SAFER Plan provides information relating to site history as well as the scope and planning of the investigation. Therefore, this information will not be repeated in this CR.

  19. Underground storage tank management plan, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    The Underground Storage Tank (UST) Program at the Oak Ridge Y-12 Plant was established to locate UST systems at the facility and to ensure that all operating UST systems are free of leaks. UST systems have been removed or upgraded in accordance with Tennessee Department of Environment and Conservation (TDEC) regulations and guidance. With the closure of a significant portion of the USTs, the continuing mission of the UST Management Program is to manage the remaining active UST systems and continue corrective actions in a safe regulatory compliant manner. This Program outlines the compliance issues that must be addressed, reviews the current UST inventory and compliance approach, and presents the status and planned activities associated with each UST system. The UST Program provides guidance for implementing TDEC regulations and guidelines for petroleum UST systems. The plan is divided into three major sections: (1) regulatory requirements, (2) active UST sites, and (3) out-of-service UST sites. These sections describe in detail the applicable regulatory drivers, the UST sites addressed under the Program, and the procedures and guidance for compliance.

  20. Cesium removal demonstration utilizing crystalline silicotitanate sorbent for processing Melton Valley Storage Tank supernate: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Walker, J.F. Jr.; Taylor, P.A.; Cummins, R.L. [and others

    1998-03-01

    This report provides details of the Cesium Removal Demonstration (CsRD), which was conducted at Oak Ridge National Laboratory (ORNL) on radioactive waste from the Melton Valley Storage Tanks. The CsRD was the first large-scale use of state-of-the-art sorbents being developed by private industry for the selective removal of cesium and other radionuclides from liquid wastes stored across the DOE complex. The crystalline silicotitanate sorbent used in the demonstration was chosen because of its effectiveness in laboratory tests using bench-scale columns. The demonstration showed that the cesium could be removed from the supernate and concentrated on a small-volume, solid waste form that would meet the waste acceptance criteria for the Nevada Test Site. During this project, the CsRD system processed > 115,000 L (30,000 gal) of radioactive supernate with minimal operational problems. Sluicing, drying, and remote transportation of the sorbent, which could not be done on a bench scale, were successfully demonstrated. The system was then decontaminated to the extent that it could be contact maintained with the use of localized shielding only. By utilizing a modular, transportable design and placement within existing facilities, the system can be transferred to different sites for reuse. The initial unit has now been removed from the process building and is presently being reinstalled for use in baseline operations at ORNL.

  1. Investigation of methods to transfer heat from solar liquid-heating collectors to heat storage tanks. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Horel, J. D.; de Winter, F.

    1978-04-20

    A study was made of the methods available to transfer heat from the collector to the water storage tank in water heating systems. In counterflow heat exchangers used in double loop water heating systems, it was found to be more important to use a high water flowrate than a high heat transfer fluid flowrate. It was earlier thought to be best to have matched WC/sub p/ (mass flowrate-specific heat) products in the loops. It was shown in this study that the water WC/sub p/ product should be about twice as large as that of the heat transfer fluid. It was found that neither the heat exchanger type nor the size was very critical, so that very simple criteria were adequate in determining optimum heat exchanger size. It was found that there is a definite system size below which one should use a traced tank or a coil in a tank. Equations and optimization criteria were developed for traced tanks or tanks with coils. At present, there is no quantitative understanding of liquid to liquid (direct contact) heat exchangers, though they are clearly quite effective. Draindown systems are discussed, and several appendices are included on heat transfer and other characteristics of fluid and of equipment.

  2. Corrosion Verification Test for the Welds of CEFR Sodium Storage Tank and Sodium Drainage Under the First-Grade Accident

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The main purpose of this test is to observe and analyze the compatibility between the welds and hightemperature sodium at the simulated realistic working conditions of CEFR sodium storage tank andsodium drainage under the first-grade accident. The observation and analysis are focused on theintergranular corrosion at the weld and its heat affection region, in order to provide the test basis for thesafe operation and analysis of CEFR.

  3. Nitrogen bubbling in expansion vessels and storage tanks for makeup water; Kvaevgasbubbling i expansionskaerl och lagertankar foer spaedvatten

    Energy Technology Data Exchange (ETDEWEB)

    Wilgotson, Fredrik; Hansson, Helen [Carl Bro Energikonsult AB, Stockholm (Sweden)

    2004-03-01

    Oxygen and carbon dioxide induced corrosion and biological growth are two problems associated with storage tanks for demineralised water as well as with atmospheric expansion vessels. The aim of this project was to investigate if it is possible to reduce or perhaps even eliminate those problems by bubbling nitrogen through the water. The investigation shows that the nitrogen flow is of great importance for the result.

  4. Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 134: Aboveground Storage Tanks, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Restoration

    2008-05-31

    This Streamlined Approach for Environmental Restoration (SAFER) Plan identifies the activities required for the closure of Corrective Action Unit (CAU) 134, Aboveground Storage Tanks. CAU 134 is currently listed in Appendix III of the Federal Facility Agreement and Consent Order (FFACO) (FFACO, 1996; as amended February 2008) and consists of four Corrective Action Sites (CASs) located in Areas 3, 15, and 29 of the Nevada Test Site (NTS) (Figure 1): (1) CAS 03-01-03, Aboveground Storage Tank; (2) CAS 03-01-04, Tank; (3) CAS 15-01-05, Aboveground Storage Tank; and (4) CAS 29-01-01, Hydrocarbon Stain. CAS 03-01-03 consists of a mud tank that is located at the intersection of the 3-07 and the 3-12 Roads in Area 3 of the NTS. The tank and its contents are uncontaminated and will be dispositioned in accordance with applicable federal, state, and local regulations. This CAS will be closed by taking no further action. CAS 03-01-04 consists of a potable water tank that is located at the Core Complex in Area 3 of the NTS. The tank will be closed by taking no further action. CAS 15-01-05 consists of an aboveground storage tank (AST) and associated impacted soil, if any. This CAS is located on a steep slope near the Climax Mine in Area 15 of the NTS. The AST is empty and will be dispositioned in accordance with applicable federal, state, and local regulations. Soil below the AST will be sampled to identify whether it has been impacted by chemicals at concentrations exceeding the action levels. It appears that the tank is not at its original location. Soil will also be sampled at the original tank location, if it can be found. If soil at either location has been impacted at concentrations that exceed the action levels, then the extent of contamination will be identified and a use restriction (UR) will be implemented. The site may be clean closed if contamination is less than one cubic yard in extent and can be readily excavated. If action levels are not exceeded, then no

  5. DimCuve : An Automatic Tool for the Optimisation of the Design and Realization of a Raw Palm oil Storage Tank

    Directory of Open Access Journals (Sweden)

    A. NGUIDJOL

    2010-12-01

    Full Text Available This paper concerns the study of the design and realization of a storage tank for raw palm oil. The main objective is to solve the problems of supply shortages of raw palm oil to stock-out to small and Medium Size Enterprises in Cameroon. We first of all look at the state-of-the-art of the design and realization of storage tanks, and then, and in the case of raw palm oil storage, we design an open cylindrical vertical tank with a conical roof supported by a ramework. We then proceed with the sizing of all the structural elements based on specially chosen mechanical criteria. We put in place software, DimCuve, to be used for the automatic sizing of storage tanks. The interest of this work is conclusive for enterprises of this sector.

  6. Underground Storage Tanks, haz mat data set attribute, Published in 2006, 1:1200 (1in=100ft) scale, Washoe County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Underground Storage Tanks dataset, published at 1:1200 (1in=100ft) scale, was produced all or in part from Published Reports/Deeds information as of 2006. It is...

  7. Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System - 1997 Notice of Violation Consent Order

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Susan Kay; Orchard, B. J.

    2002-01-01

    This Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System is one of two documents that comprise the Sampling and Analysis Plan for the HWMA/RCRA closure certification of the TRA-731 caustic and acid storage tank system at the Idaho National Engineering and Environmental Laboratory. This plan, which provides information about the project description, project organization, and quality assurance and quality control procedures, is to be used in conjunction with the Field Sampling Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System. This Quality Assurance Project Plan specifies the procedures for obtaining the data of known quality required by the closure activities for the TRA-731 caustic and acid storage tank system.

  8. Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System - 1997 Notice of Violation Consent Order

    Energy Technology Data Exchange (ETDEWEB)

    Evans, S.K.

    2002-01-31

    This Quality Assurance Project Plan for the HWMA/RCRA Closure Certification of the TRA- 731 Caustic and Acid Storage Tank System is one of two documents that comprise the Sampling and Analysis Plan for the HWMA/RCRA closure certification of the TRA-731 caustic and acid storage tank system at the Idaho National Engineering and Environmental Laboratory. This plan, which provides information about the project description, project organization, and quality assurance and quality control procedures, is to be used in conjunction with the Field Sampling Plan for the HWMA/RCRA Closure Certification of the TRA-731 Caustic and Acid Storage Tank System. This Quality Assurance Project Plan specifies the procedures for obtaining the data of known quality required by the closure activities for the TRA-731 caustic and acid storage tank system.

  9. Steady-state and dynamic simulation study on boil-off gas minimization and recovery strategies at LNG exporting terminals

    Science.gov (United States)

    Kurle, Yogesh

    Liquefied natural gas (LNG) is becoming one of the prominent clean energy sources with its abundance, high calorific value, low emission, and price. Vapors generated from LNG due to heat leak are called boil-off gas (BOG). As world-wide LNG productions are increasing fast, BOG generation and handling problems are becoming more critical. Also, due to stringent environmental regulations, flaring of BOG is not a viable option. In this study, typical Propane-and-Mixed-Refrigerant (C3-MR) process, storage facilities, and loading facilities are modeled and simulated to study BOG generation at LNG exporting terminals, including LNG processing, storage, and berth loading areas. Factors causing BOG are presented, and quantities of BOG generated due to each factor at each location are calculated under different LNG temperatures. Various strategies to minimize, recover, and reuse BOG are also studied for their feasibility and energy requirements. Rate of BOG generation during LNG loading---Jetty BOG (JBOG)---changes significantly with loading time. In this study, LNG vessel loading is simulated using dynamic process simulation software to obtain JBOG generation profile and to study JBOG recovery strategies. Also, fuel requirements for LNG plant to run steam-turbine driven compressors and gas-turbine driven compressors are calculated. Handling of JBOG generated from multiple loadings is also considered. The study would help proper handling of BOG problems in terms of minimizing flaring at LNG exporting terminals, and thus reducing waste, saving energy, and protecting surrounding environments.

  10. Techno-economic performance evaluation of solar tower plants with integrated multi-layered PCM thermocline thermal energy storage - A comparative study to conventional two-tank storage systems

    Science.gov (United States)

    Guedéz, Rafael; Ferruzza, Davide; Arnaudo, Monica; Rodríguez, Ivette; Perez-Segarra, Carlos D.; Hassar, Zhor; Laumert, Björn

    2016-05-01

    Solar Tower Power Plants with thermal energy storage are a promising technology for dispatchable renewable energy in the near future. Storage integration makes possible to shift the electricity production to more profitable peak hours. Usually two tanks are used to store cold and hot fluids, but this means both higher investment costs and difficulties during the operation of the variable volume tanks. Instead, another solution can be a single tank thermocline storage in a multi-layered configuration. In such tank both latent and sensible fillers are employed to decrease the related cost up to 30% and maintain high efficiencies. This paper analyses a multi-layered solid PCM storage tank concept for solar tower applications, and describes a comprehensive methodology to determine under which market structures such devices can outperform the more conventional two tank storage systems. A detail model of the tank has been developed and introduced in an existing techno-economic tool developed by the authors (DYESOPT). The results show that under current cost estimates and technical limitations the multi-layered solid PCM storage concept is a better solution when peaking operating strategies are desired, as it is the case for the two-tier South African tariff scheme.

  11. Numerical Modeling of the Effect of Thawing of Soil in the Area of Placing Tanks for Storage Fuel of Thermal Power Plants and Boiler

    Directory of Open Access Journals (Sweden)

    Polovnikov V.Yu.

    2016-01-01

    Full Text Available This paper describes the numerical modeling of heat transfer in the area placing of the tank for storage fuel of thermal power plant and boiler with considering the influence of thawing of the soil. We have established that the thawing of the soil in the area of placing of the tank for storage fuel of thermal power plant and boiler have little effect on the change of heat loss.

  12. Thermal Mode of Tanks for Storage Fuel of Thermal Power Plants and Boiler with the Influence of Engineering Facilities in the Area of their Placement

    Science.gov (United States)

    Polovnikov, V. Yu.; Makhsutbek, F. T.; Ozhikenova, Zh. F.

    2016-02-01

    This paper describes the numerical modeling of heat transfer in the area placing of the tank for storage fuel of thermal power plant and boiler with the influence of engineering construction. We have established that the presence of engineering structures in the area of placing of the tank for storage fuel of thermal power plant and boiler have little effect on the change of heat loss.

  13. Basic and Acidic Leaching of Sludge from Melton Valley Storage Tank W-25

    Energy Technology Data Exchange (ETDEWEB)

    Collins, J.L., Egan, B.Z., Beahm, E.C., Chase, C.W., Anderson, K.K.

    1997-10-01

    Bench-scale leaching tests were conducted with samples of tank waste sludge from the Melton Valley Storage Tank (MVST) Facility at Oak Ridge National Laboratory (ORNL) to evaluate separation technology processes for use in concentrating the radionuclides and reducing the volume of waste for final disposal. This paper discusses the hot cell apparatus, the characterization of the sludge, the leaching methodology, and the results obtained from a variety of basic and acidic leaching tests of samples of sludge at ambient temperature. Basic leaching tests were also conducted at 75 and 95 deg C. The major alpha-,gamma., and beta-emitting radionuclides in the centrifuged, wet sludge solids were {sup 137}Cs, {sup 60}Co, {sup 154}Eu, {sup 241}Am, {sup 244}Cm {sup 90}Sr, Pu, U, and Th. The other major metals (in addition to the U and Th) and anions were Na, Ca, Al, K, Mg, NO{sub 3}{sup -},CO{sub 3}{sup 2-}, OH{sup -}, and O{sup 2-} organic carbon content was 3.0 +/- 1.0%. The pH was 13. A surprising result was that about 93% of the {sup 137}Cs in the centrifuged, wet sludge solids was bound in the solids and could not be solubilized by basic leaching at ambient temperature and 75 deg C. However, the solubility of the {sup 137}Cs was enhanced by heating the sludge to 95 deg C. In one of the tests,about 42% of the {sup 137}Cs was removed by leaching with 6.3 M NaOH at 95 deg C.Removing {sup 137}Cs from the W-25 sludge with nitric acid was a slow process. About 13% of the {sup 137}Cs was removed in 16 h with 3.0 M HNO{sub 3}. Only 22% of the {sup 137}Cs was removed in 117 h usi 6.0 M HNO{sub 3}. Successive leaching of sludge solids with 0.5 M, 3.0 M, 3.0 M; and 6.0 M HNO{sub 3} for a total mixing time of 558 h removed 84% of the {sup 137}Cs. The use of caustic leaching prior to HNO{sub 3} leaching, and the use of HF with HNO{sub 3} in acidic leaching, increased the rate of {sup 137}Cs dissolution. Gel formation proved to be one of the biggest problems associated with HNO{sub 3

  14. A thermodynamic tank model for studying the effect of higher hydrocarbons on natural gas storage in metal-organic frameworks

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, HD; Deria, P; Farha, OK; Hupp, JT; Snurr, RQ

    2015-01-01

    Metal-organic frameworks (MOFs) are promising materials for storing natural gas in vehicular applications. Evaluation of these materials has focused on adsorption of pure methane, although commercial natural gas also contains small amounts of higher hydrocarbons such as ethane and propane, which adsorb more strongly than methane. There is, thus, a possibility that these higher hydrocarbons will accumulate in the MOF after multiple operating (adsorption/desorption) cycles, and reduce the storage capacity. To study the net effect of ethane and propane on the performance of an adsorbed natural gas (ANG) tank, we developed a mathematical model based on thermodynamics and mass balance equations that describes the state of the tank at any instant. The required inputs are the pure-component isotherms, and mixture adsorption data are calculated using the Ideal Adsorbed Solution Theory (IAST). We focused on how the "deliverable energy'' provided by the ANG tank to the engine changed over 200 operating cycles for a sample of 120 MOF structures. We found that, with any MOF, the ANG tank performance monotonically declines during early operating cycles until a "cyclic steady state'' is reached. We determined that the best materials when the fuel is 100% methane are not necessarily the best when the fuel includes ethane and propane. Among the materials tested, some top MOFs are MOF-143 > NU-800 > IRMOF-14 > IRMOF-20 > MIL-100 > NU-125 > IRMOF-1 > NU-111. MOF-143 is predicted to deliver 5.43 MJ L-1 of tank to the engine once the cyclic steady state is reached. The model also provided insights that can assist in future work to discover more promising adsorbent materials for natural gas storage.

  15. Efficiency of in-vessel composting process in removal of petroleum hydrocarbons from bottom sludge of crude oil storage tanks

    Directory of Open Access Journals (Sweden)

    K Naddafi

    2016-01-01

    Full Text Available Background and Objectives: Remaining of crude oil in storage tanks usually results in accumulating oily sludge at the bottom of the tank, which should be treated and disposed of in a suitable manner. The efficiency of in-vessel composting process in removing total petroleum hydrocarbons (TPH from bottom sludge of crude oil storage tanks was investigated in the present study. Material and methods: The sludge was mixed with immature compost at the ratios of 1:0 (as control, 1:2, 1:4, 1:6, 1:8, and 1:10 (as dry basis with the initial C:N:P and moisture content of 100:5:1 and 55% respectively for a period of 10 weeks. The moisture adjustment and mixing process were done 3 times a day during the composting period. Sampling and analysis of TPH and pH were done every week and every two days, respectively. Results: TPH removal in the 1:2, 1:4, 1:6, 1:8, and 1:10 composting reactors was 66.59, 73.19, 74.81, 80.20, and 79.91%, respectively. Thus, initial adjustment of sludge to immature compost ratios plays a great role in reduction of TPH. The results of the control reactors indicated that the main mechanism of TPH removal in the composting reactors was biological process. Conclusions: In-vessel composting by addition of immature compost as amendment is a viable choice for bioremediation of the bottom sludge of crude oil storage tanks.

  16. Assessment of soil-gas contamination at building 310 underground storage tank area, Fort Gordon, Georgia, 2010-2011

    Science.gov (United States)

    Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2012-01-01

    Soil gas was assessed for contaminants in the building 310 underground storage tank area adjacent to the Dwight D. Eisenhower Army Medical Center at Ft. Gordon, Georgia, from October 2010 to September 2011. The assessment, which also included the detection of organic compounds in soil gas, provides environmental contamination data to Fort Gordon personnel pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The study was conducted by the U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon. Soil-gas samplers were deployed below land surface at 37 locations in the building 310 underground storage tank area. Soil-gas samplers were deployed in a grid pattern near the storage tank area as well as downslope of the tank area in the direction of groundwater flow toward an unnamed tributary to Butler Creek. Total petroleum hydrocarbons were detected in 35 of the 37 soil-gas samplers at levels above the method detection level, and the combined mass of benzene, toluene, ethylbenzene, and total xylenes were detected above their detection levels in 8 of the 37 samplers. In addition, the combined masses of undecane, tridecane, and pentadecane were detected at or above their method detection levels in 9 of the 37 samplers. Other volatile organic compounds detected above their respective method detection levels were chloroform, 1,2,4-trimethylbenzene, and perchloroethylene. In addition, naphthalene, 2-methyl naphthalene, and 1,2,4-trimethylbenzene were detected below the method detection levels, but above the nondetection level.

  17. Structural acceptance criteria for the evaulation of existing double-shell waste storage tanks located at the Hanford site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Julyk, L.J.; Day, A.D.; Dyrness, A.D.; Moore, C.J.; Peterson, W.S.; Scott, M.A.; Shrivastava, H.P.; Sholman, J.S.; Watts, T.N.

    1995-09-01

    The structural acceptance criteria contained herein for the evaluation of existing underground double-shell waste storage tanks located at the Hanford Site is part of the Life Management/Aging Management Program of the Tank Waste Remediation System. The purpose of the overall life management program is to ensure that confinement of the waste is maintained over the required service life of the tanks. Characterization of the present condition of the tanks, understanding and characterization of potential degradation mechanisms, and development of tank structural acceptance criteria based on previous service and projected use are prerequisites to assessing tank integrity, to projecting the length of tank service, and to developing and applying prudent fixes or repairs. The criteria provided herein summarize the requirements for the analysis and structural qualification of the existing double-shell tanks for continued operation. Code reconciliation issues and material degradation under aging conditions are addressed. Although the criteria were developed for double-shell tanks, many of the provisions are equally applicable to single-shell tanks. However, the criteria do not apply to the evaluation of tank appurtenances and buried piping.

  18. Estimation of the proximity of private domestic wells to underground storage tanks: Oklahoma pilot study.

    Science.gov (United States)

    Weaver, James W; Murray, Andrew R; Kremer, Fran V

    2017-12-31

    For protecting drinking water supplies, the locations of areas with reliance on private domestic wells (hereafter referred to as "wells") and their relationship to contaminant sources need to be determined. A key resource in the U.S. was the 1990 Census where the source of domestic drinking water was a survey question. Two methods are developed to update estimates of the areal density of well use using readily accessible data. The first uses well logs reported to the states and the addition of housing units reported to the Census Bureau at the county, census tract and census block group scales. The second uses housing units reported to the Census and an estimated well use fraction. To limit the scope and because of abundant data, Oklahoma was used for a pilot project. The resulting well density estimates were consistent among spatial scales, and were statistically similar. High rates of well use were identified to the north and east of Oklahoma City, primarily in expanding cities located over a productive aquifer. In contrast, low rates of well use were identified in rural areas without public water systems and in Oklahoma's second largest city, Tulsa, each attributable to lack of suitable ground water. High densities of well use may be expected in rural areas without public water systems, expanding cities and suburbs, and legacy areas of well usage. The completeness of reported well logs was tested by counts from neighborhoods with known reliance on wells which showed reporting rates of 20% to 98%. Well densities in these neighborhoods were higher than the larger-scale estimates indicating that locally high densities typically exist within analysis units. A Monte Carlo procedure was used to determine that 27% of underground storage tanks that had at least one well within a typical distance of concern of 300m (1000ft). Published by Elsevier B.V.

  19. Fusibacter bizertensis sp. nov., isolated from a corroded kerosene storage tank.

    Science.gov (United States)

    Smii, Latifa; Ben Hania, Wajdi; Cayol, Jean-Luc; Joseph, Manon; Hamdi, Moktar; Ollivier, Bernard; Fardeau, Marie-Laure

    2015-01-01

    Strain LTF Kr01(T), a novel mesophilic, anaerobic, halotolerant, rod-shaped bacterium, was isolated from a drain at the bottom of a corroded kerosene storage tank of the Société Tunisienne des Industries de Raffinage (STIR), Bizerte, northern Tunisia. Cells were Gram-positive-staining rods, occurred singly or in pairs, and were motile by one lateral flagellum. Strain LTF Kr01(T) grew at temperatures between 15 and 40 °C (optimum 30 °C), between pH 5.5 and 8.2 (optimum pH 7.2) and at NaCl concentrations between 0 and 50 g l(-1) (optimum 5 g l(-1)). It reduced thiosulfate and elemental sulfur into sulfide, but did not reduce sulfate or sulfite. It utilized a wide range of carbohydrates (cellobiose, d-glucose, d-fructose, d-mannitol, d-ribose, sucrose, d-xylose, maltose, d-galactose, starch and trehalose) and produced acetate, CO2 and H2 as end products from glucose fermentation. The DNA G+C content was 37.4 mol%. The predominant cellular fatty acids were C14:0 and C16:0. Phylogenetic analysis of the 16S rRNA gene sequence suggested that Fusibacter tunisiensis was the closest relative of strain LTF Kr01(T) (gene sequence similarity of 94.6%). Based on phenotypic, phylogenetic and genotypic taxonomic characteristics, strain LTF Kr01(T) is proposed to represent a novel species of the genus Fusibacter, order Clostridiales, for which the name Fusibacter bizertensis sp. nov. is proposed. The type strain is LTF Kr01(T) ( = DSM 28034(T) = JCM 19376(T)). © 2015 IUMS.

  20. Use of the Modified Light Duty Utility Arm to Perform Nuclear Waste Cleanup of Underground Waste Storage Tanks at Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Blank, J.A.; Burks, B.L.; DePew, R.E.; Falter, D.D.; Glassell, R.L.; Glover, W.H.; Killough, S.M.; Lloyd, P.D.; Love, L.J.; Randolph, J.D.; Van Hoesen, S.D.; Vesco, D.P.

    1999-04-01

    The Modified Light Duty Utility Arm (MLDUA) is a selectable seven or eight degree-of-freedom robot arm with a 16.5 ft (5.03 m) reach and a payload capacity of 200 lb. (90.72 kg). The utility arm is controlled in either joystick-based telerobotic mode or auto sequence robotics mode. The MLDUA deployment system deploys the utility arm vertically into underground radioactive waste storage tanks located at Oak Ridge National Laboratory. These tanks are constructed of gunite material and consist of two 25 ft (7.62 m) diameter tanks in the North Tank Farm and six 50 ft (15.24 m) diameter tanks in the South Tank Farm. After deployment inside a tank, the utility arm reaches and grasps the confined sluicing end effecter (CSEE) which is attached to the hose management arm (HMA). The utility arm positions the CSEE within the tank to allow the HMA to sluice the tank's liquid and solid waste from the tank. The MLDUA is used to deploy the characterization end effecter (CEE) and gunite scarifying end effecter (GSEE) into the tank. The CEE is used to survey the tank wall's radiation levels and the physical condition of the walls. The GSEE is used to scarify the tank walls with high-pressure water to remove the wall scale buildup and a thin layer of gunite which reduces the radioactive contamination that is embedded into the gunite walls. The MLDUA is also used to support waste sampling and wall core-sampling operations. Other tools that have been developed for use by the MLDUA include a pipe-plugging end effecter, pipe-cutting end effecter, and pipe-cleaning end effecter. Washington University developed advance robotics path control algorithms for use in the tanks. The MLDUA was first deployed in June 1997 and has operated continuously since then. Operational experience in the first four tanks remediated is presented in this paper.

  1. Structural Integrity Program for the 300,000-Gallon Radioactive Liquid Waste Storage Tanks at the Idaho Nuclear Technology and Engineering Center

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, J.W.; Nenni, J.A.; Yoder, T.S.

    2003-04-22

    This report provides a record of the Structural Integrity Program for the 300,000-gal liquid waste storage tanks and associated equipment at the Idaho Nuclear Technology and Engineering Center, as required by U.S. Department of Energy M 435.1-1, ''Radioactive Waste Management Manual.'' This equipment is known collectively as the Tank Farm Facility. The conclusion of this report is that the Tank Farm Facility tanks, vaults, and transfer systems that remain in service for storage are structurally adequate, and are expected to remain structurally adequate over the remainder of their planned service life through 2012. Recommendations are provided for continued monitoring of the Tank Farm Facility.

  2. High efficient heat pump system using storage tanks to increase COP by means of the ISEC concept - Part 1: Model validation

    DEFF Research Database (Denmark)

    Rothuizen, Erasmus; Elmegaard, Brian; Markussen, Wiebke B.

    2015-01-01

    The purpose of the ISEC concept is to provide a high-efficient heat pump system for hot water production.The ISEC concept uses two storage tanks for the water, one discharged and one charged. Hot water for theindustrial process is tapped from the charged tank, while the other tank is charging....... Charging is done bycirculating the water in the tank through the condenser of a heat pump several times and thereby graduallyheating the water. The charging is done with a higher mass flow rate than the discharging to reach severalcirculations of the water during the time frame of one discharging....... This result in a lower condensingtemperature than if the water was heated in one step. Two test setups were built, one to test the performanceof the heat pump gradually heating the water and one to investigate the stratification in the storage tanks.Furthermore, a dynamic model of the system was implemented...

  3. Structural Integrity Program for the 300,000-Gallon Radioactive Liquid Waste Storage Tanks at the Idaho Nuclear Technology and Engineering Center

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Jeffrey W.

    2010-08-12

    This report provides a record of the Structural Integrity Program for the 300,000-gal liquid waste storage tanks and associated equipment at the Idaho Nuclear Technology and Engineering Center, as required by U.S. Department of Energy M 435.1-1, “Radioactive Waste Management Manual.” This equipment is known collectively as the Tank Farm Facility. This report is an update, and replaces the previous report by the same title issued April 2003. The conclusion of this report is that the Tank Farm Facility tanks, vaults, and transfer systems that remain in service for storage are structurally adequate, and are expected to remain structurally adequate over the remainder of their planned service life through 2012. Recommendations are provided for continued monitoring of the Tank Farm Facility.

  4. Determining Fuel Losses in Storage Tanks Based on Factual Saturation Pressures

    Science.gov (United States)

    Levitin, R. E.; Tryascin, R. A.

    2016-10-01

    At present, evaluation of fuel evaporative losses is based on a number of indirect parameters. Accuracy of such methods leaves much to be desired. The paper presents a method developed following the author's laboratory tests. An effective operation range of pressure vent valves in various tanks is provided, as well as low A92 gasoline losses for horizontal steel tanks at all operation temperatures.

  5. Leaking Underground Storage Tanks and Environmental Injustice: Is There a Hidden and Unequal Threat to Public Health in South Carolina?

    Science.gov (United States)

    Wilson, Sacoby; Zhang, Hongmei; Burwell, Kristen; Samantapudi, Ashok; Dalemarre, Laura; Jiang, Chengsheng; Rice, Lashanta; Williams, Edith; Naney, Charles

    2013-10-01

    There are approximately 590,000 underground storage tanks (USTs) nationwide that store petroleum or hazardous substances. Many of these tanks are leaking, which may increase the risk of exposure to contaminants that promote health problems in host neighborhoods. Within this study, we assessed disparities in the spatial distribution of leaking underground storage tanks (LUSTs) based on socioeconomic status (SES) and race/ethnicity in South Carolina (SC). Chi-square tests were used to evaluate the difference in the proportion of populations who host a LUST compared to those not hosting a LUST for all sociodemographic factors. Linear regression models were applied to examine the association of distance to the nearest LUST with relevant sociodemographic measures. As percent black increased, the distance (both in kilometers and miles) to the nearest LUST decreased. Similar results were observed for percent poverty, unemployment, persons with less than a high school education, blacks in poverty, and whites in poverty. Furthermore, chi-square tests indicated that blacks or non-whites or people with low SES were more likely to live in LUST host areas than in non-host areas. As buffer distance increased, percent black and non-white decreased. SES variables demonstrated a similar inverse relationship. Overall, burden disparities exist in the distribution of LUSTs based on race/ethnicity and SES in SC.

  6. Leaking Underground Storage Tanks and Environmental Injustice: Is There a Hidden and Unequal Threat to Public Health in South Carolina?

    Science.gov (United States)

    Wilson, Sacoby; Zhang, Hongmei; Burwell, Kristen; Samantapudi, Ashok; Dalemarre, Laura; Jiang, Chengsheng; Rice, LaShanta; Williams, Edith; Naney, Charles

    2014-01-01

    There are approximately 590,000 underground storage tanks (USTs) nationwide that store petroleum or hazardous substances. Many of these tanks are leaking, which may increase the risk of exposure to contaminants that promote health problems in host neighborhoods. Within this study, we assessed disparities in the spatial distribution of leaking underground storage tanks (LUSTs) based on socioeconomic status (SES) and race/ethnicity in South Carolina (SC). Chi-square tests were used to evaluate the difference in the proportion of populations who host a LUST compared to those not hosting a LUST for all sociodemographic factors. Linear regression models were applied to examine the association of distance to the nearest LUST with relevant sociodemographic measures. As percent black increased, the distance (both in kilometers and miles) to the nearest LUST decreased. Similar results were observed for percent poverty, unemployment, persons with less than a high school education, blacks in poverty, and whites in poverty. Furthermore, chi-square tests indicated that blacks or non-whites or people with low SES were more likely to live in LUST host areas than in non-host areas. As buffer distance increased, percent black and non-white decreased. SES variables demonstrated a similar inverse relationship. Overall, burden disparities exist in the distribution of LUSTs based on race/ethnicity and SES in SC. PMID:24729829

  7. Study on computation of optimal depth increase of embossed panels of stainless water tank for energy storage system

    Directory of Open Access Journals (Sweden)

    Dae-Hung Kang

    2016-07-01

    Full Text Available The objective of this study was to compute the optimal depth increase of the embossed panels of a stainless water tank used for an energy storage system. The pressing used to emboss the panels of the stainless water tank decreases their thickness. By assuming that the panels had the same volume before ( V o and after the change ( V c , we found an equation that computed how much the thickness of the panels decreased. According to the obtained thickness equation, the thickness of arch-embossed panels decreased by 50% relative to flat panels, and that of pyramid-embossed panels decreased by up to 30%. We also performed finite element method analyses of four flat panels, four arch-embossed panels, and four pyramid-embossed panels by applying the thickness equation for different depth increase. As a result, the optimal depth increase of the arch-embossed panels was 70–90 mm, and that of the pyramid-embossed panels was 150–200 mm. We concluded that these computed optimal depth increase could be useful in the economic design of a stainless water tank for an energy storage system.

  8. Retrofitting of a liquefaction compressor for LNG; Ueberholung eines Verfluessigungsverdichters fuer LNG

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Horst [RWE WWE NS GmbH, Nievenheim (Germany). Fluessigerdgasanlage; Hallermayer, Andreas [Hoerbiger Service Central Europe (Germany). Business Development

    2009-03-15

    RWE operates a LNG plant for peak shaving at Dormagen-Nievenheim as part of the RWE high-pressure gas supply grid. The natural gas is liquefied on site. This requires a complex liquefaction plant whose key elements are a tank, a heat exchanger, and the compressor. The plant was constructed and commissioned in 1975. After a longish standstill period, it was modernized recently, and several minor defects were repaired. The repair process is described in this contribution. It comprised damage detection and repair and was a time-consuming process. On the other hand, it illustrates that piston compressors function very reliably if regular servicing is ensured. (orig.)

  9. LNG, een ontwikkeling in beweging

    NARCIS (Netherlands)

    Wensink, M.W.; Rosmuller, N.

    2014-01-01

    Wereldwijd wordt gezocht naar alternatieven voor de huidige fossiele brandstoffen die duur en milieubelastend zijn. Eén van deze alternatieven is vloeibaar aardgas ofwel LNG (Liquefied Natural Gas). In Nederland is inmiddels een aantal tankstations voor LNG gerealiseerd, onder andere in Zwolle, Tilb

  10. Dynamic modelling of an adsorption storage tank using a hybrid approach combining computational fluid dynamics and process simulation

    Science.gov (United States)

    Mota, J.P.B.; Esteves, I.A.A.C.; Rostam-Abadi, M.

    2004-01-01

    A computational fluid dynamics (CFD) software package has been coupled with the dynamic process simulator of an adsorption storage tank for methane fuelled vehicles. The two solvers run as independent processes and handle non-overlapping portions of the computational domain. The codes exchange data on the boundary interface of the two domains to ensure continuity of the solution and of its gradient. A software interface was developed to dynamically suspend and activate each process as necessary, and be responsible for data exchange and process synchronization. This hybrid computational tool has been successfully employed to accurately simulate the discharge of a new tank design and evaluate its performance. The case study presented here shows that CFD and process simulation are highly complementary computational tools, and that there are clear benefits to be gained from a close integration of the two. ?? 2004 Elsevier Ltd. All rights reserved.

  11. 77 FR 73627 - 2012 LNG Export Study

    Science.gov (United States)

    2012-12-11

    ...] [FR Doc No: 2012-29894] DEPARTMENT OF ENERGY 2012 LNG Export Study AGENCY: Office of Fossil Energy, Department of Energy. ACTION: Notice of availability of 2012 LNG Export Study and request for comments. Freeport LNG Expansion, L.P. [FE Docket No. 10-161-LNG] and FLNG Liquefaction, LLC. Lake Charles...

  12. 33 CFR 127.319 - LNG transfer.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false LNG transfer. 127.319 Section 127... Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.319 LNG transfer. During LNG transfer operations, the following must be met: (a) The operator of the waterfront facility handling LNG shall...

  13. Systems engineering study: tank 241-C-103 organic skimming,storage, treatment and disposal options

    Energy Technology Data Exchange (ETDEWEB)

    Klem, M.J.

    1996-10-23

    This report evaluates alternatives for pumping, storing, treating and disposing of the separable phase organic layer in Hanford Site Tank 241-C-103. The report provides safety and technology based preferences and recommendations. Two major options and several varations of these options were identified. The major options were: 1) transfer both the organic and pumpable aqueous layers to a double-shell tank as part of interim stabilization using existing salt well pumping equipment or 2) skim the organic to an above ground before interim stabilization of Tank 241-C-103. Other options to remove the organic were considered but rejected following preliminary evaluation.

  14. INVESTIGATIONS OF THE FLOW INTO A STORAGE TANK BY MEANS OF ADVANCED EXPERIMENTAL AND THEORETICAL METHODS

    DEFF Research Database (Denmark)

    Jordan, Ulrike; Shah, Louise Jivan; Furbo, Simon

    2003-01-01

    Advanced experimental methods were applied to study flow structures of a water jet entering a tank from the bottom. A squared experimental glass tank with a volume of about 140 l was used. Above the inlet pipe a flat plate was installed, as shown in the figure. The goal of the investigations...... is to study the influence of the inlet device geometry and of the operating conditions (the flow rate, draw-off volume, and temperatures) on the thermal stratification in the tank. Measurements of the flow and temperature fields were carried out with two visualization techniques: - To visualize the flow field...

  15. Simulation model of stratified thermal energy storage tank using finite difference method

    Science.gov (United States)

    Waluyo, Joko

    2016-06-01

    Stratified TES tank is normally used in the cogeneration plant. The stratified TES tanks are simple, low cost, and equal or superior in thermal performance. The advantage of TES tank is that it enables shifting of energy usage from off-peak demand for on-peak demand requirement. To increase energy utilization in a stratified TES tank, it is required to build a simulation model which capable to simulate the charging phenomenon in the stratified TES tank precisely. This paper is aimed to develop a novel model in addressing the aforementioned problem. The model incorporated chiller into the charging of stratified TES tank system in a closed system. The model was developed in one-dimensional type involve with heat transfer aspect. The model covers the main factors affect to degradation of temperature distribution namely conduction through the tank wall, conduction between cool and warm water, mixing effect on the initial flow of the charging as well as heat loss to surrounding. The simulation model is developed based on finite difference method utilizing buffer concept theory and solved in explicit method. Validation of the simulation model is carried out using observed data obtained from operating stratified TES tank in cogeneration plant. The temperature distribution of the model capable of representing S-curve pattern as well as simulating decreased charging temperature after reaching full condition. The coefficient of determination values between the observed data and model obtained higher than 0.88. Meaning that the model has capability in simulating the charging phenomenon in the stratified TES tank. The model is not only capable of generating temperature distribution but also can be enhanced for representing transient condition during the charging of stratified TES tank. This successful model can be addressed for solving the limitation temperature occurs in charging of the stratified TES tank with the absorption chiller. Further, the stratified TES tank can be

  16. Corrosion Control Measures For Liquid Radioactive Waste Storage Tanks At The Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, B. J.; Subramanian, K. H.

    2012-11-27

    The Savannah River Site has stored radioactive wastes in large, underground, carbon steel tanks for approximately 60 years. An assessment of potential degradation mechanisms determined that the tanks may be vulnerable to nitrate- induced pitting corrosion and stress corrosion cracking. Controls on the solution chemistry and temperature of the wastes are in place to mitigate these mechanisms. These controls are based upon a series of experiments performed using simulated solutions on materials used for construction of the tanks. The technical bases and evolution of these controls is presented in this paper.

  17. Liquefied Natural Gas (LNG) dispenser verification device

    Science.gov (United States)

    Xiong, Maotao; Yang, Jie-bin; Zhao, Pu-jun; Yu, Bo; Deng, Wan-quan

    2013-01-01

    The composition of working principle and calibration status of LNG (Liquefied Natural Gas) dispenser in China are introduced. According to the defect of weighing method in the calibration of LNG dispenser, LNG dispenser verification device has been researched. The verification device bases on the master meter method to verify LNG dispenser in the field. The experimental results of the device indicate it has steady performance, high accuracy level and flexible construction, and it reaches the international advanced level. Then LNG dispenser verification device will promote the development of LNG dispenser industry in China and to improve the technical level of LNG dispenser manufacture.

  18. Workbook for predicting pressure wave and fragment effects of exploding propellant tanks and gas storage vessels

    Science.gov (United States)

    Baker, W. E.; Kulesz, J. J.; Ricker, R. E.; Bessey, R. L.; Westine, P. S.; Parr, V. B.; Oldham, G. A.

    1975-01-01

    Technology needed to predict damage and hazards from explosions of propellant tanks and bursts of pressure vessels, both near and far from these explosions is introduced. Data are summarized in graphs, tables, and nomographs.

  19. Dramatic inspection cost reduction of spherical storage tanks; Reduction importante des couts d'inspection des reservoires de stockage spheriques

    Energy Technology Data Exchange (ETDEWEB)

    Kiyoyuki, Ohkawa [Osaka Gas Co., Ltd (Japan)

    2000-07-01

    To ensure the safety of spherical gas holders and LPG storage tanks (hereafter called spherical storage tanks), both daily and periodic inspections are performed after the tanks become operational. One such periodic inspection involves opening the tank to check the integrity of weld lines on the inner and outer walls, but this is a costly and time-consuming task. A more suitable and efficient alternative is prescribed by standards like the Guidelines for Spherical Gas Holders published by the Japan Gas Association (hereafter called JGA Guidelines) which stipulate operational tank inspections that are conducted on the weld lines of inner and outer walls from outside the tank (i.e., external defect detection) without actually opening the tank. External defect detection technologies are widely available today, but Osaka Gas, Tokyo Gas and Toho Gas have jointly developed a high-speed TOFD (time of flight diffraction) mode that is quite different from the pulse reflection mode of ultrasonic defect detection testing prescribed by JGA Guidelines. Along these same lines, Osaka Gas also developed an inspection robot that travels along the weld line in an effort to reduce the cost of inspections still further. This paper will show that applying this newly developed inspection mode and robot to operational tank inspections will significantly reduce inspection costs, cut inspection time and improve the work environment. (authors)

  20. A REVIEW: THE EFFECT OF OPERATING CONDITIONS AND THERMAL MANAGEMENT ON THE PERFORMANCES OF METAL HYDRIDE HYDROGEN STORAGE TANK

    Directory of Open Access Journals (Sweden)

    Taurista Perdana Syawitri

    2016-12-01

    Full Text Available For safety and operability concerns, the use of metal hydrides to store hydrogen appears to be particularly promising option for alternative energy at present. However, the process of adding, removing and distributing heat during the hydrogen charging/ discharging process is problematic due to the poor effective thermal conductivity of the metal hydride porous bed and the high enthalpies of H2 adsorption/desorption. Therefore, heat transfer is a critical factor affecting the performance of metal hydride hydrogen (MHR storage tanks. Over decade, many researches focused on MHR’s operating conditions and its thermal management to improve its performance.

  1. Analysis of Thermal Energy Storage Tank by ANSYS and Comparison with Experimental Results to Improve its Thermal Efficiency

    Science.gov (United States)

    Beemkumar, N.; Karthikeyan, A.; Shiva Keshava Reddy, Kota; Rajesh, Kona; Anderson, A.

    2017-05-01

    The discontinuous temperament of the solar power forces to consider about the energy storage. This work is to analyze the tank, amount of energy stored and its storage time. The thermal and flow analysis has been done by ANSYS with different set temperature values. The experimentation is done for various encapsulating materials with different phase change material (PCM). Findings: The results obtained from experimental work are compared with ANSYS output. The competence of the TES is calculated and further improvements are made to enhance its performance. During charging process the temperature distribution from heat transfer fluid (HTF) to PCM is maximum in copper encapsulations followed by aluminium encapsulations and brass encapsulations. The comparison shows only when the electrical power as an input source. The efficient way of captivating solar energy could be a better replacement for electrical input.

  2. Modeling and analysis of chill and fill processes for the cryogenic storage and transfer engineering development unit tank

    Science.gov (United States)

    Hedayat, A.; Cartagena, W.; Majumdar, A. K.; LeClair, A. C.

    2016-03-01

    NASA's future missions may require long-term storage and transfer of cryogenic propellants. The Engineering Development Unit (EDU), a NASA in-house effort supported by both Marshall Space Flight Center (MSFC) and Glenn Research Center, is a cryogenic fluid management (CFM) test article that primarily serves as a manufacturing pathfinder and a risk reduction task for a future CFM payload. The EDU test article comprises a flight-like tank, internal components, insulation, and attachment struts. The EDU is designed to perform integrated passive thermal control performance testing with liquid hydrogen (LH2) in a test-like vacuum environment. A series of tests, with LH2 as a testing fluid, was conducted at Test Stand 300 at MSFC during the summer of 2014. The objective of this effort was to develop a thermal/fluid model for evaluating the thermodynamic behavior of the EDU tank during the chill and fill processes. The Generalized Fluid System Simulation Program, an MSFC in-house general-purpose computer program for flow network analysis, was utilized to model and simulate the chill and fill portion of the testing. The model contained the LH2 supply source, feed system, EDU tank, and vent system. The test setup, modeling description, and comparison of model predictions with the test data are presented.

  3. LABORATORY TESTING TO SIMULATE VAPOR SPACE CORROSION IN RADIOACTIVE WASTE STORAGE TANKS

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, B.; Garcia-Diaz, B.; Gray, J.

    2013-08-30

    Radioactive liquid waste has been stored in underground carbon steel tanks for nearly 70 years at the Hanford nuclear facility. Vapor space corrosion of the tank walls has emerged as an ongoing challenge to overcome in maintaining the structural integrity of these tanks. The interaction between corrosive and inhibitor species in condensates/supernates on the tank wall above the liquid level, and their interaction with vapor phase constituents as the liquid evaporates from the tank wall influences the formation of corrosion products and the corrosion of the carbon steel. An effort is underway to gain an understanding of the mechanism of vapor space corrosion. Localized corrosion, in the form of pitting, is of particular interest in the vapor space. CPP testing was utilized to determine the susceptibility of the steel in a simulated vapor space environment. The tests also investigated the impact of ammonia gas in the vapor space area on the corrosion of the steel. Vapor space coupon tests were also performed to investigate the evolution of the corrosion products during longer term exposures. These tests were also conducted at vapor space ammonia levels of 50 and 550 ppm NH{sub 3} (0.005, and 0.055 vol.%) in air. Ammonia was shown to mitigate vapor space corrosion.

  4. LNG TERMINAL SAFE OPERATION MANAGEMENT

    OpenAIRE

    Andrzej ADAMKIEWICZ; Kamiński, Włodzimierz

    2012-01-01

    W artykule przedstawiono znaczenie problemu bezpieczeństwa terminali LNG w transporcie morskim gazu ziemnego. Wskazano szczególne wymagania jakie stwarza instalacji przesył LNG, a wynikające z jego szczególnych własności. Na tle wielopoziomowych krytycznych obszarów bezpieczeństwa stanowiących elementy składowe struktury systemu bezpieczeństwa terminali wyselekcjonowano możliwości zmniejszania ryzyka wystąpienia sytuacji awaryjnej na terminalu LNG. Zdefiniowano zadania wykonywane przez termin...

  5. A Review of Common Problems in Design and Installation of Water Spray Cooling and Low Expansion Foam System to Protect Storage Tanks Containing Hydrocarbons Against Fires

    Directory of Open Access Journals (Sweden)

    Iraj Alimohammadi

    2015-12-01

    Full Text Available Tank fires are rare but carry significant potential risk to life and property. For this reason fire protection of tanks is critical. Fixed Low expansion foam and water spray cooling systems are one of the most effective and economical ways to reduce damages to a tank from fire. Such systems are currently installed in many companies but are not effective enough and require involvement of firefighters which in turn threaten their lives. This paper studies in a systematic way the problems of foam and cooling systems currently installed in a few domestic companies which operate storage tanks with focus on floating and fixed roof atmospheric tanks containing hydrocarbons and offers possible solutions for more efficient installation, design and operation of such systems.

  6. A Review of Common Problems in Design and Installation of Water Spray Cooling and Low Expansion Foam System to Protect Storage Tanks Containing Hydrocarbons Against Fires

    Directory of Open Access Journals (Sweden)

    I. Alimohammadi

    2015-11-01

    Full Text Available Tank fires are rare but carry significant potential risk to life and property. For this reason fire protection of tanks is critical. Fixed Low expansion foam and water spray cooling systems are one of the most effective and economical ways to reduce damages to a tank from fire. Such systems are currently installed in many companies but are not effective enough and require involvement of firefighters which in turn threaten their lives. This paper studies in a systematic way the problems of foam and cooling systems currently installed in a few domestic companies which operate storage tanks with focus on floating and fixed roof atmospheric tanks containing hydrocarbons and offers possible solutions for more efficient installation, design and operation of such systems.

  7. Development of Hydrogen Storage Tank Systems Based on Complex Metal Hydrides

    Directory of Open Access Journals (Sweden)

    Morten B. Ley

    2015-09-01

    Full Text Available This review describes recent research in the development of tank systems based on complex metal hydrides for thermolysis and hydrolysis. Commercial applications using complex metal hydrides are limited, especially for thermolysis-based systems where so far only demonstration projects have been performed. Hydrolysis-based systems find their way in space, naval, military and defense applications due to their compatibility with proton exchange membrane (PEM fuel cells. Tank design, modeling, and development for thermolysis and hydrolysis systems as well as commercial applications of hydrolysis systems are described in more detail in this review. For thermolysis, mostly sodium aluminum hydride containing tanks were developed, and only a few examples with nitrides, ammonia borane and alane. For hydrolysis, sodium borohydride was the preferred material whereas ammonia borane found less popularity. Recycling of the sodium borohydride spent fuel remains an important part for their commercial viability.

  8. INHIBITION OF STRESS CORROSION CRACKING OF CARBON STEEL STORAGE TANKS AT HANFORD

    Energy Technology Data Exchange (ETDEWEB)

    BOOMER, K.D.

    2007-01-31

    The stress corrosion cracking (SCC) behavior of A537 tank steel was investigated in a series of environments designed to simulate the chemistry of legacy nuclear weapons production waste. Tests consisted of both slow strain rate tests using tensile specimens and constant load tests using compact tension specimens. Based on the tests conducted, nitrite was found to be a strong SCC inhibitor. Based on the test performed and the tank waste chemistry changes that are predicted to occur over time, the risk for SCC appears to be decreasing since the concentration of nitrate will decrease and nitrite will increase.

  9. 国内储罐清洗作业及对策%Domestic Storage Tank Cleaning Operations and Countermeasures

    Institute of Scientific and Technical Information of China (English)

    宋生奎; 张永国; 王杰辉; 徐克明; 王文娟

    2014-01-01

    Storage tank cleaning was a regular work activity in the petrochemical industry and manual cleaning operation forms were still used for cleaning many domestic tanks.Manual cleaning methods and the main problems existing in the cleaning process were analyzed and the necessity of using automatic mechanical cleaning system and the advantages of its overall efficiency and no environmental pollution were pointed out.To narrow the gap with foreign countries , it recommended that a mobile , vehicle-mounted and integrated tank cleaning system should be developed to clean all kinds of medium and small tanks , which had broad market prospects and good social and economic benefits.%储罐清洗是石化行业一项经常性的作业活动,国内许多储罐依然采用人工清洗的作业形式,分析了人工清洗方式及其清洗过程中存在的主要问题,指出储罐采用自动机械清洗系统的必要性及其综合效益显著、无环境污染等优点;为缩小与国外的差距,建议开发研制机动性、车载式、集成化的油罐清洗系统以清洗各种中、小型的储油罐,其市场前景广阔并有良好的社会效益与经济效益。

  10. Biodegradation of international jet A-1 aviation fuel by microorganisms isolated from aircraft tank and joint hydrant storage systems.

    Science.gov (United States)

    Itah, A Y; Brooks, A A; Ogar, B O; Okure, A B

    2009-09-01

    Microorganisms contaminating international Jet A-1 aircraft fuel and fuel preserved in Joint Hydrant Storage Tank (JHST) were isolated, characterized and identified. The isolates were Bacillus subtillis, Bacillus megaterium, Flavobacterium oderatum, Sarcina flava, Micrococcus varians, Pseudomonas aeruginosa, Bacillus licheniformis, Bacillus cereus and Bacillus brevis. Others included Candida tropicalis, Candida albicans, Saccharomyces estuari, Saccharomyces cerevisiae, Schizosaccharomyces pombe, Aspergillus flavus, Aspergillus niger, Aspergillus fumigatus, Cladosporium resinae, Penicillium citrinum and Penicillium frequentans. The viable plate count of microorganisms in the Aircraft Tank ranged from 1.3 (+/-0.01) x 104 cfu/mL to 2.2 (+/-1.6) x 104 cfu/mL for bacteria and 102 cfu/mL to 1.68 (+/-0.32) x 103 cfu/mL for fungi. Total bacterial counts of 1.79 (+/-0.2) x 104 cfu/mL to 2.58 (+/-0.04) x 104 cfu/mL and total fungal count of 2.1 (+/-0.1) x 103 cfu/mL to 2.28 (+/-0.5) x 103 cfu/mL were obtained for JHST. Selected isolates were re-inoculated into filter sterilized aircraft fuels and biodegradation studies carried out. After 14 days incubation, Cladosporium resinae exhibited the highest degradation rate with a percentage weight loss of 66 followed by Candida albicans (60.6) while Penicillium citrinum was the least degrader with a weight loss of 41.6%. The ability of the isolates to utilize the fuel as their sole source of carbon and energy was examined and found to vary in growth profile between the isolates. The results imply that aviation fuel could be biodegraded by hydrocarbonoclastic microorganisms. To avert a possible deterioration of fuel quality during storage, fuel pipe clogging and failure, engine component damage, wing tank corrosion and aircraft disaster, efficient routine monitoring of aircraft fuel systems is advocated.

  11. Resource Conservation and Recovery Act (RCRA) Part B permit application for tank storage units at the Oak Ridge Y-12 Plant

    Energy Technology Data Exchange (ETDEWEB)

    1994-05-01

    In compliance with the Resource Conservation and Recovery Act (RCRA), this report discusses information relating to permit applications for three tank storage units at Y-12. The storage units are: Building 9811-1 RCRA Tank Storage Unit (OD-7); Waste Oil/Solvent Storage Unit (OD-9); and Liquid Organic Solvent Storage Unit (OD-10). Numerous sections discuss the following: Facility description; waste characteristics; process information; groundwater monitoring; procedures to prevent hazards; contingency plan; personnel training; closure plan, post closure plan, and financial requirements; record keeping; other federal laws; organic air emissions; solid waste management units; and certification. Sixteen appendices contain such items as maps, waste analyses and forms, inspection logs, equipment identification, etc.

  12. Think Tanks

    Science.gov (United States)

    2001-01-01

    A new inspection robot from Solex Robotics Systems was designed to eliminate hazardous inspections of petroleum and chemical storage tanks. The submersible robot, named Maverick, is used to inspect the bottoms of tanks, keeping the tanks operational during inspection. Maverick is able to provide services that will make manual tank inspections obsolete. While the inspection is conducted, Maverick's remote human operators remain safe outside of the tank. The risk to human health and life is now virtually eliminated. The risk to the environment is also minimal because there is a reduced chance of spillage from emptying and cleaning the tanks, where previously, tons of pollutants were released through the process of draining and refilling.

  13. Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 124: Storage Tanks, Nevada Test Site, Nevada (Draft), Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Alfred Wickline

    2007-04-01

    This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses closure for Corrective Action Unit (CAU) 124, Areas 8, 15, and 16 Storage Tanks, identified in the Federal Facility Agreement and Consent Order. Corrective Action Unit 124 consists of five Corrective Action Sites (CASs) located in Areas 8, 15, and 16 of the Nevada Test Site as follows: • 08-02-01, Underground Storage Tank • 15-02-01, Irrigation Piping • 16-02-03, Underground Storage Tank • 16-02-04, Fuel Oil Piping • 16-99-04, Fuel Line (Buried) and UST This plan provides the methodology of field activities necessary to gather information to close each CAS. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 124 using the SAFER process.

  14. Study on Thermal Storage Process of Solar Energy in Molten Salt Thermal Storage Tank%太阳能熔盐蓄热罐蓄热过程的性能研究

    Institute of Scientific and Technical Information of China (English)

    王兴; 靳智平; 刘宏丽

    2015-01-01

    By using numerical simulation method, the melting and thermal storage process of molten salt in the thermal storage tank was studied. The results showed that tubes pitches have important influence on the melting process of molten salt in the same thermal storage tank. The tank with 200 mm tubes pitches is of better storage ability than that with 120 mm, and the temperature distribution in molten salt tank is more uniform. The results will provide a reference to the structural design and optimization of the thermal storage tank.%对太阳能熔盐蓄热罐的熔化和蓄热过程进行了数值模拟研究,结果表明相同蓄热罐不同的加热内管间距对熔化和蓄热过程有着显著影响.其中,200 mm管间距的蓄热罐熔化和蓄热过程较管间距为120 mm的蓄热快,并且温度分布比较均匀.研究结论对蓄热罐的结构设计和优化运行具有一定的参考价值.

  15. Managing Underground Storage Tank Data Using dBASE III PLUS.

    Science.gov (United States)

    1987-06-01

    indicate Name of Principal CERCLA Substance CASNO= Chemical Abstract Service (CAS) No. M = Mixture UNKNOWN I lul 1 U = Unknown *Codes are taken from... Chemical Abstract Service (CAS) No Mark box 3 of tank stores a .xture of substances UNKNOWN d. Unknown -- , -- ’ , 9. Addltional Information (for lanks

  16. Method for Calculating Costs of Underground Storage Tank Closure at Fort Dix, New Jersey

    Science.gov (United States)

    1991-09-01

    OIL#6 Hazardous Substance __ Indicate Principal CERCLA Substance ___ ___ ___ chemical Abstract Service (CAS) No. ___ ___ ___ ___ ___ Mixture... Chemical Abstract Service (CAS) No. ___ ___ ___ ___ Mixture Unknown __ ------------------------ ------- I -------* ----- ------ -------- I...Substance Indicate Principal CERCLA Substance ____________ Chemical Abstract Service (CAS) No. _________ Mixture __ Unknown __ 1li. Date Tank Last

  17. Prevention of stress-corrosion cracking in nuclear waste storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Ondrejcin, R S

    1984-01-01

    Stress corrosion cracking (SCC) has occurred in the early versions of carbon steel primaries of nuclear waste tanks at the Savannah River Plant. (Secondary containment was provided by a vessel surrounding the lower portion of the primary tank.) Evaporated alkaline nitrate wastes in the form of crystallized salts are being dissolved from some of these tanks for transfer to new tanks of a different design. To prevent the SCC sequence from occurring during salt dissolution, the levels of inhibitors required to prevent cracking at yield stresses were determined. Special statistically designed experiments were performed to evaluate the probability of cracking under the combined influences of nitrate, nitrite, hydroxide, and temperature. Experimentlly, samples were tested by a potentially controlled constant extension rate test and by wedge opening loaded samples. Two equations were derived by multivariable regression analyses that correlated probability of cracking as the dependent variable to nitrate, nitrite, and hydroxide concentrations and temperature as the independent variables. From these equations, simple operating standards were developed by setting the probability of cracking equal to zero and solving for the four independent variables. 15 references, 15 figures, 8 tables.

  18. Dismantlement and removal of Old Hydrofracture Facility bulk storage bins and water tank, Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The Old Hydrofracture Facility (OHF), located at Oak Ridge National Laboratory (ORNL), was constructed in 1963 to allow experimentation and operations with an integrated solid storage, mixing, and grout injection facility. During its operation, OHF blended liquid low-level waste with grout and used a hydrofracture process to pump the waste into a deep low-permeable shale formation. Since the OHF Facility was taken out of service in 1980, the four bulk storage bins located adjacent to Building 7852 had deteriorated to the point that they were a serious safety hazard. The ORNL Surveillance and Maintenance Program requested and received permission from the US Department of Energy to dismantle the bins as a maintenance action and send the free-released metal to an approved scrap metal vendor. A 25,000-gal stainless steel water tank located at the OHF site was included in the scope. A fixed-price subcontract was signed with Allied Technology Group, Inc., to remove the four bulk storage bins and water tank to a staging area where certified Health Physics personnel could survey, segregate, package, and send the radiologically clean scrap metal to an approved scrap metal vendor. All radiologically contaminated metal and metal that could not be surveyed was packaged and staged for later disposal. Permissible personnel exposure limits were not exceeded, no injuries were incurred, and no health and safety violations occurred throughout the duration of the project. Upon completion of the dismantlement, the project had generated 53,660 lb of clean scrap metal (see Appendix D). This resulted in $3,410 of revenue generated and a cost avoidance of an estimated $100,000 in waste disposal fees.

  19. Efficacy of LNG IUS

    Directory of Open Access Journals (Sweden)

    Uma Pandey

    2016-02-01

    Results: There were 35 women who were included in this observational study. 94.28% (33/35 women had LNG IUS inserted in theatre whilst 5.7% (2/35 had in the outpatients department. There was improvement in menstrual symptoms in 80% of the patients. There was no relief in the endometriosis group. Total abdominal hysterectomy was performed in 7 women who had endometriosis (20%. Conclusions: In my observational study 80% of women are satisfied with the device and had relief in their symptoms. In view of HMB's high prevalence, an optimal treatment for this kind of menstrual symptoms is very important especially in developing world set up where resources aren't easily available. [Int J Reprod Contracept Obstet Gynecol 2016; 5(2.000: 445-447

  20. Safety in Liquefied Natural Gas (LNG) Operations

    Energy Technology Data Exchange (ETDEWEB)

    Buhrow, C. [Technische Univ. Bergakademie, Freiberg (Germany). Lehrstuhl Bergbau/Tiefbau; Niemann-Delius, C.; Okafor, E. [Technische Hochschule Aachen (Germany). Lehrstuhl und Inst. fuer Bergbaukunde 3

    2005-07-01

    Germany needs an LNG receiving terminal to import LNG and supplement expected future gas supply shortages. Enormous economic benefits also abound if Germany is to install an LNG receiving terminal. Jobs will be created for several hundred people. New tax revenues will be generated for state and local governments and this will further enhance the economic competitiveness of Germany. Additionally, it will provide Germany with a reliable source of clean-burning energy. Any proposed LNG receiving terminal should incorporate safety right from the start. These safety requirements will: ensure that certain public land uses, people, and structures outside the LNG facility boundaries are protected in the event of LNG fire, prevent vapour clouds associated with an LNG spill from reaching a property line that can be built upon, prevent severe burns resulting from thermal radiation, specify requirements for design, construction and use of LNG facilities and other equipments, and promote safe, secure and reliable LNG operations. The German future LNG business will not be complete without the evolution of both local and international standards that can apply to LNG operations. Currently existing European standards also appear inadequate. With an OHSAS 18001 management system integrated with other existing standards we can better control our LNG occupational health and safety risks, and improve performance in the process. Additionally, an OHSAS 18001 System will help future German LNG contractors and operators safeguard their most important assets - their employees. (orig.)

  1. Tank designs for combined high pressure gas and solid state hydrogen storage

    DEFF Research Database (Denmark)

    Mazzucco, Andrea

    for each storage solution investigated in this work. Attention is given to solutions that involve high-pressure solid-state and gas hydrogen storage with an integrated passive cooling system. A set of libraries is implemented in the modeling platform to select among different material compositions, kinetic......Many challenges have still to be overcome in order to establish a solid ground for significant market penetration of fuel cell hydrogen vehicles. The development of an effective solution for on-board hydrogen storage is one of the main technical tasks that need to be tackled. The present thesis...... deals with the development of a simulation tool to design and compare different vehicular storage options with respect to targets based upon storage and fueling efficiencies. The set targets represent performance improvements with regard to the state-of-the-art technology and are separately defined...

  2. Foundation design of vertical steel storage tank%立式钢制储罐基础设计

    Institute of Scientific and Technical Information of China (English)

    杨文武

    2014-01-01

    以某罐区立式钢制储罐基础设计为例,探讨预制桩、灌注桩和浅基础应用于储罐基础的设计方法。储罐基础设计可比拟为"板-柱结构"体系,借助pkpm结构软件分析两种桩型承载力、浅基础设计、场地条件影响及桩-土共同作用。储罐桩基设计应对水平承载力、竖向承载力和配筋量三控制设计,对于端承型桩基,一般情况下单桩水平承载力起控制作用。相同桩数时,采用方形布桩的边桩配筋比环形布桩的更易产生突变。应用于软土场地的砼预制桩不仅应进行桩基承载力计算,还应加强桩基配筋验算。%Based on a foundation design of vertical steel storage tank in a tank farm , the application of precast piles , pile and shallow foun-dation design method on the basis of the tank were discussed .Tank foundation design can be compared to "plate -column structure"sys-tem, by using PKPM structure software , analysis of bearing capacity , shallow foundation design , site condition and pile -soil interaction of two kinds of pile type were carried out .The horizontal bearing capacity , vertical bearing capacity and reinforcement amount should be controlled in the tank design .For end bearing type piles , single pile horizontal bearing capacity plays a general controlling role .The edge pile reinforcement ratio of square pile arrangement produces mutation more likely than annular arrangement under same number of pile .It is necessary to calculate not only foundation bearing capacity of pile but also foundation reinforcement when precast concrete piles are ap -plied in the soft soil ground .

  3. Effects of inlet momentum and orientation on the hydraulic performance of water storage tanks

    Science.gov (United States)

    Xavier, Manoel Lucas Machado; Janzen, Johannes Gérson

    2017-09-01

    The influence of inlet momentum and inlet orientation on hydraulic performance of cylindrical water process tanks were investigated using a factorial design strategy. The hydraulic performance of the tanks was assessed with a computational fluid dynamics (CFD) model, which calculated the flow fields and the residence time distribution (RTD). RTDs were used to quantify the tanks hydraulic performance using hydraulic indexes that represent short-circuiting, mixing, and moment. These indexes were later associated with the effluent fraction of disinfectant (inlet and outlet disinfectant ratio). For small depth-to-diameter ratios, the inlet orientation and the inlet momentum were the most important factors regarding the hydraulic indexes and the effluent fraction of disinfectant, respectively. A poor correlation was obtained between the hydraulic indexes and the effluent fraction of disinfectant, indicating that they are not good predictors for water quality. For large depth-to-diameter ratios, the inlet orientation had the most significant effect on both the hydraulic indexes and effluent fraction of disinfectant. The short-circuiting and mixing indexes presented a good correlation with water quality for this case.

  4. 关于静载作用下大型储罐罐壁的合理设计%On the Reasonable Design of Tank Wall of Large Storage Tank under Static Loads

    Institute of Scientific and Technical Information of China (English)

    卜凡; 钱才富

    2013-01-01

    罐壁是大型储罐的重要部件,其设计是否合理决定着整个储罐是否安全和经济。目前各国大型储罐的设计准则不同,设计结果也有差异。分别根据中国标准GB 50341-2003的设计方法与美国标准API 650-2007中的“变设计点法”,对容积为1×105 m3与2×105 m3的2个受静载作用的大型储罐进行设计,并比较两种设计方法的差异,同时通过有限元软件ANSYS对罐壁进行优化设计,以期得到更经济可行的设计方案。%Tank wall is the most important component in a large storage tank .Reasonable design of the tank wall determines the safety and economy of the whole tank .Different countries have different design criterias for the design of large storage tanks , and as a result , giving different results .Two large storage tanks with the capacity of 1 ×105 m3 and 2 ×105 m3 under the static loads were designed based on the de-sign criteria in China standard GB 50341-2003 and the Variable-Design-Point Method in USA stand-ard API 650-2007 and compared for the wall thickness .At the same time , the optimization design was performed with the finite element software ANSYS in order to obtain a more economic and feasible design approach .

  5. Dehydration and desalting of heavy crude Maya into the TMDB by means of tanks of storage of 500 TB converted to type gun-barrel

    Energy Technology Data Exchange (ETDEWEB)

    Cisneros, L.F.L.; Abundes, A.A.; Aguinaga, C.A.L.; Monroy, J.D.A.; Jimenez, R.M.; Sanchez, M.R.; Medina, J.L.H.; Vazquez, J.V.; Montano, A.E.G.; Villanueva, A.G.; Moreno, W.N.C.; Maria, G.B.; Mendez, J.L.J.; Cordero, E.D.; Ponce, F.C.; Estrada, C.D.; Azuara, V.H.C. [Petroleos Mexicanos, PEMEX, Mexico City (Mexico)

    2009-07-01

    When crude oil emerges from the production well, it is polluted with congenital waters and in some cases with sea water. These waters can be present as free water or emulsified. When the water reaches the surface, the free water is eliminated by sedimentation. However, the reduction of emulsified water is not directly due to the stability presented by the drops of emulsified water in the crude, therefore chemical injection for the separation of both phases is required. This paper discussed the design of a system for dehydration and desalting of 750 TBD Maya heavy crude, by means of tanks type gun-barrel. The design was performed using the simulation packages HYSYS and computational fluid dynamics of ANSYS, considering the parameters that were studied in bottle tests and profiled in tanks storage of 500 TB. The design was based on the settling speed that affects the dehydration and desalting of crude. The paper discussed the production facilities used in the crude dehydration, with particular reference to the gun barrel tank; washer tank; heat treater tanks; free water separator; and electrostatic separator. The development of the system was described in terms of data compilation using Stokes' Law and interpretation of the field data using bottle tests. It was concluded that the gun barrel train was the best option to dehydrate and desalt Mayan oil in the TMDB, since this processing system takes advantage of the existing facilities, specifically the storage tanks of 500 TB capacity. 16 refs., 5 tabs., 5 figs.

  6. LNG terminalil on idaraha keeld / Raimo Poom

    Index Scriptorium Estoniae

    Poom, Raimo

    2011-01-01

    Euroopa Komisjon kiirustab Balti riike LNG (vedeldatud maagaasi) terminali asukohas kokku leppima. Kolmest tingimusest, millele peab LNG terminali projekt vastama, et tekiks võimalus kandideerida EL-i toetusele

  7. Sinopec to Launch LNG Project in Shandong

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ Sinopec has beaten out its domestic rivals-CNOOC and CNPC to win the rights to build a liquefied national (LNG) gas terminal in East China's Shandong Province. Sinopec's move breaks CNOOC's monopoly in building LNG projects along China's coastline.

  8. Analysis of Underground Storage Tanks System Materials to Increased Leak Potential Associated with E15 Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kass, Michael D [ORNL; Theiss, Timothy J [ORNL; Janke, Christopher James [ORNL; Pawel, Steven J [ORNL

    2012-07-01

    include model year 2001 light-duty vehicles, but specifically prohibited use in motorcycles and off-road vehicles and equipment. UST stakeholders generally consider fueling infrastructure materials designed for use with E0 to be adequate for use with E10, and there are no known instances of major leaks or failures directly attributable to ethanol use. It is conceivable that many compatibility issues, including accelerated corrosion, do arise and are corrected onsite and, therefore do not lead to a release. However, there is some concern that higher ethanol concentrations, such as E15 or E20, may be incompatible with current materials used in standard gasoline fueling hardware. In the summer of 2008, DOE recognized the need to assess the impact of intermediate blends of ethanol on the fueling infrastructure, specifically located at the fueling station. This includes the dispenser and hanging hardware, the underground storage tank, and associated piping. The DOE program has been co-led and funded by the Office of the Biomass Program and Vehicle Technologies Program with technical expertise from the Oak Ridge National Laboratory (ORNL) and the National Renewable Energy Laboratory (NREL). The infrastructure material compatibility work has been supported through strong collaborations and testing at Underwriters Laboratories (UL). ORNL performed a compatibility study investigating the compatibility of fuel infrastructure materials to gasoline containing intermediate levels of ethanol. These results can be found in the ORNL report entitled Intermediate Ethanol Blends Infrastructure Materials Compatibility Study: Elastomers, Metals and Sealants (hereafter referred to as the ORNL intermediate blends material compatibility study). These materials included elastomers, plastics, metals and sealants typically found in fuel dispenser infrastructure. The test fuels evaluated in the ORNL study were SAE standard test fuel formulations used to assess material-fuel compatibility within a

  9. Analysis of Underground Storage Tanks System Materials to Increased Leak Potential Associated with E15 Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kass, Michael D [ORNL; Theiss, Timothy J [ORNL; Janke, Christopher James [ORNL; Pawel, Steven J [ORNL

    2012-07-01

    include model year 2001 light-duty vehicles, but specifically prohibited use in motorcycles and off-road vehicles and equipment. UST stakeholders generally consider fueling infrastructure materials designed for use with E0 to be adequate for use with E10, and there are no known instances of major leaks or failures directly attributable to ethanol use. It is conceivable that many compatibility issues, including accelerated corrosion, do arise and are corrected onsite and, therefore do not lead to a release. However, there is some concern that higher ethanol concentrations, such as E15 or E20, may be incompatible with current materials used in standard gasoline fueling hardware. In the summer of 2008, DOE recognized the need to assess the impact of intermediate blends of ethanol on the fueling infrastructure, specifically located at the fueling station. This includes the dispenser and hanging hardware, the underground storage tank, and associated piping. The DOE program has been co-led and funded by the Office of the Biomass Program and Vehicle Technologies Program with technical expertise from the Oak Ridge National Laboratory (ORNL) and the National Renewable Energy Laboratory (NREL). The infrastructure material compatibility work has been supported through strong collaborations and testing at Underwriters Laboratories (UL). ORNL performed a compatibility study investigating the compatibility of fuel infrastructure materials to gasoline containing intermediate levels of ethanol. These results can be found in the ORNL report entitled Intermediate Ethanol Blends Infrastructure Materials Compatibility Study: Elastomers, Metals and Sealants (hereafter referred to as the ORNL intermediate blends material compatibility study). These materials included elastomers, plastics, metals and sealants typically found in fuel dispenser infrastructure. The test fuels evaluated in the ORNL study were SAE standard test fuel formulations used to assess material-fuel compatibility within a

  10. 苯乙烯储罐防聚合控制措施及效果%INHIBITION MEASURES AND EFFECT ON STYRENE STORAGE TANK

    Institute of Scientific and Technical Information of China (English)

    成英刚; 翟士刚

    2014-01-01

    针对齐鲁储运厂苯乙烯储存过程中出现的聚合现象,以142#储罐为例,采用联合研发的延缓苯乙烯聚合的新型储罐内防腐涂料及施工工艺,同时对原氮封系统进行了改造。4 a 多的实际运行结果表明,142#储罐罐体及储罐的死角(透光孔)等部位均未发现聚合物,阻聚效果明显;142#储罐内苯乙烯产品的质量达到指标要求,且延长了苯乙烯储罐清罐周期,具有良好的经济和环境效益。%Aimed at polymerization phenomenon existing storage course of styrene in Qilu Storage & Transportation Complex, taken No.142 storage tank as an example, the original nitro-gen sealing system was reformed by combined technologies of adopting new type anticorrosive coating in the storage tank and construction process.The practical running results in more than 4 yeas showed that no polymer was found in shell and dead space (light hole) of the No.142 stor-age tank, inhibition was obviously obtained.Product quality of styrene in the No.142 storage tank met index requirements, and tank clean period was prolonged.Good economic and envi-ronmental profits were obtained.

  11. 苯乙烯储罐防聚合控制措施及效果%INHIBITION MEASURES AND EFFECT ON STYRENE STORAGE TANK

    Institute of Scientific and Technical Information of China (English)

    成英刚; 翟士刚

    2015-01-01

    Aimed at polymerization phenomenon existing storage course of styrene in Qilu Storage &Transportation Complex, taken No.142 storage tank as an example, the original nitro-gen sealing system was reformed by combined technologies of adopting new type anticorrosive coating in the storage tank and construction process.The practical running results in more than 4 yeas showed that no polymer was found in shell and dead space ( light hole) of the No.142 stor-age tank, inhibition was obviously obtained.Product quality of styrene in the No.142 storage tank met index requirements, and tank clean period was prolonged.Good economic and envi-ronmental profits were obtained.%针对齐鲁储运厂苯乙烯储存过程中出现的聚合现象,以142#储罐为例,采用联合研发的延缓苯乙烯聚合的新型储罐内防腐涂料及施工工艺,同时对原氮封系统进行了改造。4 a多的实际运行结果表明,142#储罐罐体及储罐的死角(透光孔)等部位均未发现聚合物,阻聚效果明显;142#储罐内苯乙烯产品的质量达到指标要求,且延长了苯乙烯储罐清罐周期,具有良好的经济和环境效益。

  12. Passive Capillary Pumped Cryocooling System for Zero-Boil-Off Cryogen Storage Tanks Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Significant cost and weight savings of a space mission can be achieved by improving the cryogenic storage technology. Added cryogen mass due to the cryogen boil-off,...

  13. Performance Analysis and Application of Three Different Computational Methods for Solar Heating System with Seasonal Water Tank Heat Storage

    Directory of Open Access Journals (Sweden)

    Dongliang Sun

    2013-01-01

    Full Text Available We analyze and compare three different computational methods for a solar heating system with seasonal water tank heat storage (SHS-SWTHS. These methods are accurate numerical method, temperature stratification method, and uniform temperature method. The accurate numerical method can accurately predict the performance of the system, but it takes about 4 to 5 weeks, which is too long and hard for the performance analysis of this system. The temperature stratification method obtains relatively accurate computation results and takes a relatively short computation time, which is about 2 to 3 hours. Therefore, this method is most suitable for the performance analysis of this system. The deviation of the computational results of the uniform temperature method is great, and the time consumed is similar to that of the temperature stratification method. Therefore, this method is not recommended herein. Based on the above analyses, the temperature stratification method is applied to analyze the influence of the embedded depth of water tank, the thickness of thermal insulation material, and the collection area on the performance of this system. The results will provide a design basis for the related demonstration projects.

  14. Issues associated with manipulator-based waste retrieval from Hanford underground storage tanks with a preliminary review of commercial concepts

    Energy Technology Data Exchange (ETDEWEB)

    Berglin, E.J.

    1996-09-17

    Westinghouse Hanford Company (WHC) is exploring commercial methods for retrieving waste from the underground storage tanks at the Hanford site in south central Washington state. WHC needs data on commercial retrieval systems equipment in order to make programmatic decisions for waste retrieval. Full system testing of retrieval processes is to be demonstrated in phases through September 1997 in support of programs aimed to Acquire Commercial Technology for Retrieval (ACTR) and at the Hanford Tanks Initiative (HTI). One of the important parts of the integrated testing will be the deployment of retrieval tools using manipulator-based systems. WHC requires an assessment of a number of commercial deployment systems that have been identified by the ACTR program as good candidates to be included in an integrated testing effort. Included in this assessment should be an independent evaluation of manipulator tests performed to date, so that WHC can construct an integrated test based on these systems. The objectives of this document are to provide a description of the need, requirements, and constraints for a manipulator-based retrieval system; to evaluate manipulator-based concepts and testing performed to date by a number of commercial organizations; and to identify issues to be resolved through testing and/or analysis for each concept.

  15. Offshore Deepwater Liquified Natural Gas (LNG) Ports ...

    Science.gov (United States)

    2017-04-10

    EPA received three National Pollution Discharge Elimination System (NPDES) permit applications for wastewater discharges related to the construction and operation of deepwater LNG ports in state and federal waters of Massachusetts Bay. One was for construction-related discharges associated with the Northeast Gateway LNG deepwater port, one was for operations-related discharges associated with the Northeast Gateway LNG deepwater port, and the other was for both construction-related and operations-related discharges for the Neptune LNG deepwater port.

  16. High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 7

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    This Requirements Identification Document (RID) describes an Occupational Health and Safety Program as defined through the Relevant DOE Orders, regulations, industry codes/standards, industry guidance documents and, as appropriate, good industry practice. The definition of an Occupational Health and Safety Program as specified by this document is intended to address Defense Nuclear Facilities Safety Board Recommendations 90-2 and 91-1, which call for the strengthening of DOE complex activities through the identification and application of relevant standards which supplement or exceed requirements mandated by DOE Orders. This RID applies to the activities, personnel, structures, systems, components, and programs involved in maintaining the facility and executing the mission of the High-Level Waste Storage Tank Farms.

  17. Sanitary evaluation of domestic water supply facilities with storage tanks and detection of Aeromonas, enteric and related bacteria in domestic water facilities in Okinawa Prefecture of Japan.

    Science.gov (United States)

    Miyagi, Kazufumi; Sano, Kouichi; Hirai, Itaru

    2017-08-01

    To provide for temporary restrictions of the public water supply system, storage tanks are commonly installed in the domestic water systems of houses and apartment buildings in Okinawa Prefecture of Japan. To learn more about the sanitary condition and management of these water supply facilities with storage tanks (hereafter called "storage tank water systems") and the extent of bacterial contamination of water from these facilities, we investigated their usage and the existence of Aeromonas, enteric and related bacteria. Verbal interviews concerning the use and management of the storage tank water systems were carried out in each randomly sampled household. A total of 54 water samples were collected for bacteriological and physicochemical examinations. Conventional methods were used for total viable count, fecal coliforms, identification of bacteria such as Aeromonas, Enterobacteriaceae and non-fermentative Gram-negative rods (NF-GNR), and measurement of residual chlorine. On Aeromonas species, tests for putative virulence factor and an identification using 16S rRNA and rpoB genes were also performed. Water from the water storage systems was reported to be consumed directly without boiling in 22 of the 54 houses (40.7%). 31 of the sampled houses had installed water storage tanks of more than 1 cubic meter (m(3)) per inhabitant, and in 21 of the sampled houses, the tank had never been cleaned. In all samples, the total viable count and fecal coliforms did not exceed quality levels prescribed by Japanese waterworks law. Although the quantity of bacteria detected was not high, 23 NF-GNR, 14 Enterobacteriaceae and 5 Aeromonas were isolated in 42.6%, 7.4% and 3.7% of samples respectively. One isolated A. hydrophila and four A. caviae possessed various putative virulence factors, especially A. hydrophila which had diverse putative pathogenic genes such as aer, hlyA, act, alt, ast, ser, and dam. Many bacteria were isolated when the concentration of residual chlorine

  18. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 7. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Burt, D.L.

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 7) presents the standards and requirements for the following sections: Occupational Safety and Health, and Environmental Protection.

  19. HANFORD TANK CLEANUP UPDATE

    Energy Technology Data Exchange (ETDEWEB)

    BERRIOCHOA MV

    2011-04-07

    Access to Hanford's single-shell radioactive waste storage tank C-107 was significantly improved when workers completed the cut of a 55-inch diameter hole in the top of the tank. The core and its associated cutting equipment were removed from the tank and encased in a plastic sleeve to prevent any potential spread of contamination. The larger tank opening allows use of a new more efficient robotic arm to complete tank retrieval.

  20. Exergy Efficient Application of LNG Cold

    NARCIS (Netherlands)

    Stougie, L.; Van der Kooi, H.J.

    2010-01-01

    The worldwide demand for Liquefied Natural Gas (LNG) is growing, which results in numerous LNG import terminals being under construction. In the interest of sustainable development, it is important to decide carefully upon which technology to apply for evaporating the LNG to natural gas. Three optio

  1. Comparison between models for the simulation of hot water storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Oliveski, R.D.C. [Universidade do Vale do Rio dos Sinos, Sao Leopoldo, RS (Brazil). Centro de Ciencas Exatas e Tecnologicas, Engenharia Mecanica; Krenzinger, A. [Universiade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil). Departamento de Engenharia de Materiais; Vielmo, H.A. [Universiade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil). Departamento de Engenharia Mecanica

    2003-08-01

    Numerical and experimental analyses of velocity and temperature fields inside a tank submitted to internal natural and mixed convection are presented in this paper. The numerical analyses were performed with two approaches: one using a two-dimensional model in cylindrical coordinates through the finite volume method and another using a one-dimensional model. A turbulence model for low Reynolds numbers was added to the two--dimensional model in mixed convection regime. The two-dimensional model was experimentally validated and then adopted as reference. Its results were compared to those obtained with one-dimensional models (combined with certain computational artifices described in this work) with a good agreement. (author)

  2. A dispersion safety factor for LNG vapor clouds

    Energy Technology Data Exchange (ETDEWEB)

    Vílchez, Juan A. [TIPs – Trámites, Informes y Proyectos, SL, Llenguadoc 10, 08030 Barcelona (Spain); Villafañe, Diana [Centre d’Estudis del Risc Tecnològic (CERTEC), Universitat Politècnica de Catalunya, Diagonal 647, 08028 Barcelona, Catalonia (Spain); Casal, Joaquim, E-mail: joaquim.casal@upc.edu [Centre d’Estudis del Risc Tecnològic (CERTEC), Universitat Politècnica de Catalunya, Diagonal 647, 08028 Barcelona, Catalonia (Spain)

    2013-02-15

    Highlights: ► We proposed a new parameter: the dispersion safety factor (DSF). ► DSF is the ratio between the distance reached by the LFL and that reached by the visible cloud. ► The results for the DSF agree well with the evidence from large scale experiments. ► Two expressions have been proposed to calculate DSF as a function of H{sub R}. ► The DSF may help in indicating the danger of ignition of a LNG vapor cloud. -- Abstract: The growing importance of liquefied natural gas (LNG) to global energy demand has increased interest in the possible hazards associated with its storage and transportation. Concerning the event of an LNG spill, a study was performed on the relationship between the distance at which the lower flammability limit (LFL) concentration occurs and that corresponding to the visible contour of LNG vapor clouds. A parameter called the dispersion safety factor (DSF) has been defined as the ratio between these two lengths, and two expressions are proposed to estimate it. During an emergency, the DSF can be a helpful parameter to indicate the danger of cloud ignition and flash fire.

  3. Tank Lay-Up Information Package and List of Questions for US Department of Energy High-Level Waste Tank Storage Sites

    Energy Technology Data Exchange (ETDEWEB)

    Elmore, Monte R.; Henderson, Colin

    2002-06-21

    This document provides background information and a list of questions to be addressed during an information-gathering visit by Jacobs Engineering Group Inc personnel. Jacobs has been funded by the Tanks Focus Area to complete a task "Pre-closure Interim Tanks Maintenance." The overall objective of this task is to develop a central informaion center of site conditions, site requirements, alternative technical and other approaches, closure plans and activities, regulatory drivers and methodolgies for decision-making to assist site decisdion-makers in teh evaluation of alternative high-level waste (HLW) tank lay-up configureations. Lay-up is the term used for the period between intial decontamination and decommissioning of the tanks and final closure. Successful lay-up will place the tanks in a safe, stable, and minimum-maintenance mode until final closure.

  4. Fuzzy fault tree assessment based on improved AHP for fire and explosion accidents for steel oil storage tanks.

    Science.gov (United States)

    Shi, Lei; Shuai, Jian; Xu, Kui

    2014-08-15

    Fire and explosion accidents of steel oil storage tanks (FEASOST) occur occasionally during the petroleum and chemical industry production and storage processes and often have devastating impact on lives, the environment and property. To contribute towards the development of a quantitative approach for assessing the occurrence probability of FEASOST, a fault tree of FEASOST is constructed that identifies various potential causes. Traditional fault tree analysis (FTA) can achieve quantitative evaluation if the failure data of all of the basic events (BEs) are available, which is almost impossible due to the lack of detailed data, as well as other uncertainties. This paper makes an attempt to perform FTA of FEASOST by a hybrid application between an expert elicitation based improved analysis hierarchy process (AHP) and fuzzy set theory, and the occurrence possibility of FEASOST is estimated for an oil depot in China. A comparison between statistical data and calculated data using fuzzy fault tree analysis (FFTA) based on traditional and improved AHP is also made. Sensitivity and importance analysis has been performed to identify the most crucial BEs leading to FEASOST that will provide insights into how managers should focus effective mitigation.

  5. According to the LNG Accident on LNG Gasification Station Safety Management%从 LNG 事故浅谈 LNG 气化站安全管理

    Institute of Scientific and Technical Information of China (English)

    罗冬林

    2012-01-01

      近年来国内 LNG 发展非常快,但由于 LNG 行业在国内普及时间较短,相关的 LNG 气化站的安全管理制度还不太成熟,针对 LNG 的特性分析其事故机理,阐述安全管理预防措施,为 LNG 气化站日常安全运行管理提供借鉴

  6. LNG vehicle technology, economics, and safety assessment

    Science.gov (United States)

    Powars, Charles A.; Moyer, Carl B.; Lowell, Douglas D.

    1994-02-01

    Liquid natural gas (LNG) is an attractive transportation fuel because of its high heating value and energy density (i.e., Btu/lb. and Btu/gal.), clean burning characteristics, relatively low cost ($/Btu), and domestic availability. This research evaluated LNG vehicle and refueling system technology, economics, and safety. Prior and current LNG vehicle projects were studied to identify needed technology improvements. Life-cycle cost analyses considered various LNG vehicle and fuel supply options. Safety records, standards, and analysis methods were reviewed. The LNG market niche is centrally fueled heavy-duty fleet vehicles with high fuel consumption. For these applications, fuel cost savings can amortize equipment capital costs.

  7. Environmental and Economic Impact of Underground Storage Tanks in the United States and Territories

    Science.gov (United States)

    1992-12-01

    Pemex ), the Mexico City based state oil company, has accepted responsibility for the gasoline leak into the sewer system and offered to provide $32.7...owned and operated by Pemex , which crossed the southeast part of the city and supplied one of the main storage and distribution plants with gasoline

  8. LNG fuelling for mine trucks

    Energy Technology Data Exchange (ETDEWEB)

    Melanson, B.E.; Hodgins, K.B. [Westport Innovations Inc., Vancouver, BC (Canada)

    2006-07-01

    Diesel-powered mine haul trucks consume large amounts of fuel. The diesel engines provide the trucks with the flexibility to readily move material while optimizing speed and efficiency. However, the high cost for diesel fuel has prompted the need for lower-cost solutions. Since many mining regions have access to low-cost liquefied natural gas (LNG) feedstock through indigenous natural gas resources and coal mine methane, the use of LNG for mine haul trucks offers a solution to lower operating costs. In addition to reducing the reliance on petroleum resources, the use of LNG would also contribute to a reduction in noise, air pollutants, and greenhouse gas emissions. This presentation demonstrated that significant fuel cost savings can be realized in regions where LNG has cost advantage to diesel fuel. High pressure direct injection (HPDI) of natural gas in a compression ignition engine offers the high performance and efficiency characteristics of diesel engines while reducing particulate matter, nitrogen oxides, sulphur oxides and greenhouse gases. HPDI has been demonstrated in on-road Class 8 trucks since 2001 and mine haul trucks are now considered a prime target for implementing change to lower-carbon gaseous fuels. The supply of LNG fuel will be a necessary aspect of the introduction of HPDI to mining. LNG can be transported to mine sites or it can be produced on or near mining operations that have access to methane sources or pipelines. It was concluded that HPDI powered mine trucks offer a safe, economic and environmentally progressive solution for mine operators. 2 figs.

  9. In-situ strain monitoring in liquid containers of LNG transporting carriers

    Science.gov (United States)

    Oh, Min-Cheol; Seo, Jun-Kyu; Kim, Kyung-Jo; Lee, Sang-Min; Kim, Myung-Hyun

    2008-08-01

    Liquefied natural gas (LNG) transport carriers are exposed to a risk by the repeated bump in the LNG container during the vessel traveling over the wave in ocean. The liquid inside the container, especially when it was not fully contained, make a strong bump onto the insulation panel of the tank wall. The insulation panel consists of several layers of thick polyurethane foam (PUF) to maintain the LNG below the cryogenic temperature, -162°C. Due to the repeated shock on the PUF, a crack could be developed on the tank wall causing a tremendous disaster for LNG carriers. To prevent the accidental crack on the tank, a continuous monitoring of the strain imposed on the PUF is recommended. In this work, a fiber-optic Bragg grating was imbedded inside the PUF for monitoring the strain parallel to the impact direction. The optical fiber sensor with a small diameter of 125 μm was suitable to be inserted in the PUF through a small hole drilled after the PUF was cured. In-situ monitoring of the strain producing the change of Bragg reflection wavelength, a high speed wavelength interrogation method was employed by using an arrayed waveguide grating. By dropping a heavy mass on the PUF, we measured the strain imposed on the insulation panel.

  10. Energy saving by improvement in heat storage tank. Complex building `Sun Pedeck` management by CBS; Chikunetsuso kairyonado de shoene. Sogo tatemono `Sun Pedeck` (kabushiki kaisha CBS)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-01

    An example in which energy was considerably saved by improving the underground heat storage tank in complex building `Sun Pedeck` in front of Tsudanuma Station is introduced as the interview of an excellent business. Many speciality shops and restaurants move into this complex building, and the building consists of three buildings containing offices and cultural facilities. Therefore, the complicated management that the complex building is in the open state throughout the year and variously limited in equipment replacement is required. Since a cold-water tank of 450 tons under the ground is an initial heat storage tank, cold water is accumulated only at the bottom. This was very low in efficiency. A weir was thus installed in the cool-water tank to improve so that the water flow meanders up and down. At 10:00 p.m. to 8:00 a.m. that is the midnight time zone of power, a turbo-refrigerating machine for regenerative heat storage operates between 7:00 and 8:00 in the early morning so as to produce cool water. The annual power rate could be reduced 6,000,000 yen by circulating the heat-reserved cool water between 2:30 p.m. and 3:30 p.m. 6 figs.

  11. Performance of electric forklift with low-temperature polymer exchange membrane fuel cell power module and metal hydride hydrogen storage extension tank

    Science.gov (United States)

    Lototskyy, Mykhaylo V.; Tolj, Ivan; Parsons, Adrian; Smith, Fahmida; Sita, Cordellia; Linkov, Vladimir

    2016-06-01

    We present test results of a commercial 3-tonne electric forklift (STILL) equipped with a commercial fuel cell power module (Plug Power) and a MH hydrogen storage tank (HySA Systems and TF Design). The tests included: (i) performance evaluation of "hybrid" hydrogen storage system during refuelling at low (pressures; (ii) comparison of the forklift performances during heavy-duty operation when changing the powering in the series: standard battery - fuel cell power module (alone) - power module with integrated MH tank; and (iii) performance tests of the forklift during its operation under working conditions. It was found that (a) the forklift with power module and MH tank can achieve 83% of maximum hydrogen storage capacity during 6 min refuelling (for full capacity 12-15 min); (b) heavy-duty operation of the forklift is characterised by 25% increase in energy consumption, and during system operation more uniform power distribution occurs when operating in the fuel cell powering mode with MH, in comparison to the battery powering mode; (c) use of the fully refuelled fuel cell power module with the MH extension tank allows for uninterrupted operation for 3 h 6 min and 7 h 15 min, for heavy- and light-duty operation, respectively.

  12. Thermo-mechanical Analysis of Cold Helium Injection into Gas Storage Tanks made of Carbon Steel Following Resistive Transition of the LHC Magnets

    CERN Document Server

    Chorowski, M

    1998-01-01

    A resistive transition (quench) of the LHC sector magnets will be followed by cold helium venting to a quench buffer volume of 2000 m3 at ambient temperature. The volume will be composed of eight medi um-pressure (2 MPa) gas storage tanks made of carbon steel, which constrains the temperature of the wall to be higher than -50oC (223 K). The aim of the analysis is the assessment of a possible spot c ooling intensity and thermo-mechanical stresses in the tank wall following helium injection.

  13. Technical Assessment of Cryo-Compressed Hydrogen Storage Tank Systems for Automotive Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ahluwalia, Rajesh [Argonne National Lab. (ANL), Argonne, IL (United States); Hua, T. Q. [Argonne National Lab. (ANL), Argonne, IL (United States); Peng, J. -K. [Argonne National Lab. (ANL), Argonne, IL (United States); Lasher, S. [TIAX LLC, Lexington, MA (United States); McKenney, Kurtis [TIAX LLC, Lexington, MA (United States); Sinha, J. [TIAX LLC, Lexington, MA (United States)

    2009-12-01

    Technical report describing DOE's second assessment report on a third generation (Gen3) system capable of storing hydrogen at cryogenic temperatures within a pressure vessel on-board a vehicle. The report includes an overview of technical progress to date, including the potential to meet DOE onboard storage targets, as well as independent reviews of system cost and energy analyses of the technology paired with delivery costs.

  14. Numerical Investigation of Stratified Thermal Storage Tank Applied in Adsorption Heat Pump Cycle

    OpenAIRE

    Taheri, Hadi

    2014-01-01

    With the aid of the TES (Thermal Energy Storage) in the adsorption heat pump cycle, the COP of the system can be improved. Different geometrical variations of the TES with stratification device, have been investigated numerically. Furthermore,The effective thermal conductivity has been analyzed. The simulation results of a reference CFD model have been compared with experimental results. Additionally, the porous medium impact on the mixing process and turbulence has been studied numerically.

  15. Organic liquids storage tanks volatile organic compounds (VOCS) emissions dispersion and risk assessment in developing countries: the case of Dar-es-Salaam City, Tanzania.

    Science.gov (United States)

    Jackson, Msafiri M

    2006-05-01

    The emission estimation of nine volatile organic compounds (VOCs) from eight organic liquids storage tanks companies in Dar-es-Salaam City Tanzania has been done by using US EPA standard regulatory storage tanks emission model (TANKS 4.9b). Total VOCs atmospheric emission has been established to be 853.20 metric tones/yr. It has been established further that petrol storage tanks contribute about 87% of total VOCs emitted, while tanks for other refined products and crude oil were emitting 10% and 3% of VOCs respectively. Of the eight sources (companies), the highest emission value from a single source was 233,222.94 kg/yr and the lowest single source emission value was 6881.87 kg/yr. The total VOCs emissions estimated for each of the eight sources were found to be higher than the standard level of 40,000 kg/yr per source for minor source according to US EPA except for two sources, which were emitting VOCs below the standard level. The annual emissions per single source for each of the VOCs were found to be below the US EPA emissions standard which is 2,000 kg/yr in all companies except the emission of hexane from company F1 which was slightly higher than the standard. The type of tanks used seems to significantly influence the emission rate. Vertical fixed roof tanks (VFRT) emit a lot more than externally floating roof tanks (EFRT) and internally floating roof tanks (IFRT). The use of IFRT and EFRT should be encouraged especially for storage of petrol which had highest atmospheric emission contribution. Model predicted atmospheric emissions are less than annual losses measured by companies in all the eight sources. It is possible that there are other routes for losses beside atmospheric emissions. It is therefore important that waste reduction efforts in these companies are directed not only to reducing atmospheric emissions, but also prevention of the spillage and leakage of stored liquid and curbing of the frequently reported illegal siphoning of stored products

  16. 78 FR 38703 - LNG Development Company (d/b/a Oregon LNG); Oregon Pipeline Company, LLC; Notice of Application

    Science.gov (United States)

    2013-06-27

    ... Energy Regulatory Commission LNG Development Company (d/b/a Oregon LNG); Oregon Pipeline Company, LLC; Notice of Application Take notice that on June 7, 2013, LNG Development Company, LLC (d/ b/a Oregon LNG) (Oregon LNG), 8100 NE Parkway Drive, Suite 165, Vancouver, WA 98662, filed in Docket No. CP9-6-001...

  17. 77 FR 43589 - Freeport LNG Development, L.P., Freeport LNG Expansion, L.P., FLNG Liquefaction LLC; Supplemental...

    Science.gov (United States)

    2012-07-25

    ... Energy Regulatory Commission Freeport LNG Development, L.P., Freeport LNG Expansion, L.P., FLNG... proposed by Freeport LNG Development, L.P., Freeport LNG Expansion, L.P, and FLNG Liquefaction LLC... existing liquefied natural gas (LNG) import terminal on Quintana Island in Brazoria County, Texas....

  18. 77 FR 38790 - Noble Americas Gas & Power Corp., LNG Development Company, LLC, LNG Development Company, LLC (d/b...

    Science.gov (United States)

    2012-06-29

    ... Americas Gas & Power Corp., LNG Development Company, LLC, LNG Development Company, LLC (d/b/a Oregon LNG... Corp. authority to import/ export natural gas from/ to Canada/Mexico, and to import LNG from various international sources by vessel. 3099 05/31/12 12-43-NG LNG Development Order granting blanket Company,...

  19. 76 FR 53440 - Freeport LNG Development, LP; Freeport LNG Expansion, LP; FLNG Liquefaction LLC; Notice of Intent...

    Science.gov (United States)

    2011-08-26

    ... Energy Regulatory Commission Freeport LNG Development, LP; Freeport LNG Expansion, LP; FLNG Liquefaction... construction and operation of facilities proposed by Freeport LNG Development, LP, Freeport LNG Expansion, LP... liquefied natural gas (LNG) import terminal on Quintana Island in Brazoria County, Texas. The Project...

  20. 77 FR 58373 - Trunkline LNG Company, LLC; Trunkline LNG Export, LLC; Trunkline Gas Company, LLC; Notice of...

    Science.gov (United States)

    2012-09-20

    ... Energy Regulatory Commission Trunkline LNG Company, LLC; Trunkline LNG Export, LLC; Trunkline Gas Company... Project involving construction and operation of facilities by Trunkline LNG Company, LLC/Trunkline LNG... Trunkline plans to expand its existing liquefied natural gas (LNG) terminal in Calcasieu Parish,...

  1. PIF4 Promotes Expression of LNG1 and LNG2 to Induce Thermomorphogenic Growth in Arabidopsis

    Directory of Open Access Journals (Sweden)

    Geonhee Hwang

    2017-07-01

    Full Text Available Arabidopsis plants adapt to high ambient temperature by a suite of morphological changes including elongation of hypocotyls and petioles and leaf hyponastic growth. These morphological changes are collectively called thermomorphogenesis and are believed to increase leaf cooling capacity by enhancing transpiration efficiency, thereby increasing tolerance to heat stress. The bHLH transcription factor PHYTOCHROME INTERACTING FACTOR4 (PIF4 has been identified as a major regulator of thermomorphogenic growth. Here, we show that PIF4 promotes the expression of two homologous genes LONGIFOLIA1 (LNG1 and LONGIFOLIA2 (LNG2 that have been reported to regulate leaf morphology. ChIP-Seq analyses and ChIP assays showed that PIF4 directly binds to the promoters of both LNG1 and LNG2. The expression of LNG1 and LNG2 is induced by high temperature in wild type plants. However, the high temperature activation of LNG1 and LNG2 is compromised in the pif4 mutant, indicating that PIF4 directly regulates LNG1 and LNG2 expression in response to high ambient temperatures. We further show that the activities of LNGs support thermomorphogenic growth. The expression of auxin biosynthetic and responsive genes is decreased in the lng quadruple mutant, implying that LNGs promote thermomorphogenic growth by activating the auxin pathway. Together, our results demonstrate that LNG1 and LNG2 are directly regulated by PIF4 and are new components for the regulation of thermomorphogenesis.

  2. Fuelling the future with LNG

    NARCIS (Netherlands)

    Anonymous

    2013-01-01

    It is important to be able to quantify risks in order to determine LNG behaviour and to ensure its containment. This facilitates comprehensive safety management. Quantitative risk assessments are necessary to enable the selection of preventive and protective measures that suit the situation. Every s

  3. Fuelling the future with LNG

    NARCIS (Netherlands)

    Anonymous

    2013-01-01

    It is important to be able to quantify risks in order to determine LNG behaviour and to ensure its containment. This facilitates comprehensive safety management. Quantitative risk assessments are necessary to enable the selection of preventive and protective measures that suit the situation. Every

  4. OPTIMIZATION OF INTERNAL HEAT EXCHANGERS FOR HYDROGEN STORAGE TANKS UTILIZING METAL HYDRIDES

    Energy Technology Data Exchange (ETDEWEB)

    Garrison, S.; Tamburello, D.; Hardy, B.; Anton, D.; Gorbounov, M.; Cognale, C.; van Hassel, B.; Mosher, D.

    2011-07-14

    Two detailed, unit-cell models, a transverse fin design and a longitudinal fin design, of a combined hydride bed and heat exchanger are developed in COMSOL{reg_sign} Multiphysics incorporating and accounting for heat transfer and reaction kinetic limitations. MatLab{reg_sign} scripts for autonomous model generation are developed and incorporated into (1) a grid-based and (2) a systematic optimization routine based on the Nelder-Mead downhill simplex method to determine the geometrical parameters that lead to the optimal structure for each fin design that maximizes the hydrogen stored within the hydride. The optimal designs for both the transverse and longitudinal fin designs point toward closely-spaced, small cooling fluid tubes. Under the hydrogen feed conditions studied (50 bar), a 25 times improvement or better in the hydrogen storage kinetics will be required to simultaneously meet the Department of Energy technical targets for gravimetric capacity and fill time. These models and methodology can be rapidly applied to other hydrogen storage materials, such as other metal hydrides or to cryoadsorbents, in future work.

  5. 接管腐蚀与贮罐风险防范%Risk Prevention of Storage Tank Caused by Pipe Corrosion

    Institute of Scientific and Technical Information of China (English)

    赵家福

    2016-01-01

    This paper introduced the regular inspection of the carbon dioxide storage tank. During the veriifcation of pressure gauge calibration, we found pipe corrosion and expansion of the pressure gauge on the top of the tank inadvertently. This article analyzed the status, the causes and dangers of the corrosion, and put forward the preventive measures. Our aim was to avoid nasty accidents on the tanks in our district, caused by small pipe.%本文介绍了在定期检验中发现二氧化碳贮罐罐顶压力表接管腐蚀膨胀,对该腐蚀的现状和产生的原因及危害性做了分析,提出了今后的防范措施,以避免小接管引发大事故。

  6. 液化烃储罐水喷雾冷却系统设计%Designing of Water-Spray Cooling System for Liquefied Hydrocarbon Storage Tanks

    Institute of Scientific and Technical Information of China (English)

    赵彦永

    2000-01-01

    通过对液化烃储罐火灾特点及水喷雾冷却系统灭火机理的分析,对液化烃储罐水喷雾消防冷却系统的设计方法加以探讨。提出了"罐上喷头工作压力为定值"的假设,从而简化了设计计算。%Discussions are made on the methods for designing water-spray cooling system for liquefied hydrocarbonstorage tanks through analyzing the characteristics of the fire hazards with liquefied hydrocarbon storage tanks and the fireextinguishing mechanism of water-spray cooling system, with the hypothesis of "The working pressure of the spray nozzleson the tanks is a set value." advanced,so that design calculations are simplified.

  7. Seismic Fragility Analysis of a Condensate Storage Tank with Age-Related Degradations

    Energy Technology Data Exchange (ETDEWEB)

    Nie, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Braverman, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Hofmayer, C [Brookhaven National Lab. (BNL), Upton, NY (United States); Choun, Y-S [Brookhaven National Lab. (BNL), Upton, NY (United States); Kim, MK [Brookhaven National Lab. (BNL), Upton, NY (United States); Choi, I-K [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2011-04-01

    The Korea Atomic Energy Research Institute (KAERI) is conducting a five-year research project to develop a realistic seismic risk evaluation system which includes the consideration of aging of structures and components in nuclear power plants (NPPs). The KAERI research project includes three specific areas that are essential to seismic probabilistic risk assessment (PRA): (1) probabilistic seismic hazard analysis, (2) seismic fragility analysis including the effects of aging, and (3) a plant seismic risk analysis. Since 2007, Brookhaven National Laboratory (BNL) has entered into a collaboration agreement with KAERI to support its development of seismic capability evaluation technology for degraded structures and components. The collaborative research effort is intended to continue over a five year period. The goal of this collaboration endeavor is to assist KAERI to develop seismic fragility analysis methods that consider the potential effects of age-related degradation of structures, systems, and components (SSCs). The research results of this multi-year collaboration will be utilized as input to seismic PRAs. This report describes the research effort performed by BNL for the Year 4 scope of work. This report was developed as an update to the Year 3 report by incorporating a major supplement to the Year 3 fragility analysis. In the Year 4 research scope, an additional study was carried out to consider an additional degradation scenario, in which the three basic degradation scenarios, i.e., degraded tank shell, degraded anchor bolts, and cracked anchorage concrete, are combined in a non-perfect correlation manner. A representative operational water level is used for this effort. Building on the same CDFM procedure implemented for the Year 3 Tasks, a simulation method was applied using optimum Latin Hypercube samples to characterize the deterioration behavior of the fragility capacity as a function of age-related degradations. The results are summarized in Section 5

  8. 地震激励下的储罐动压力理论分析%Theoretical Analysis of Storage Tanks' Dynamic Pressure under Earthquake Excitation

    Institute of Scientific and Technical Information of China (English)

    李敏; 张霖; 李洪明

    2013-01-01

    Both research findings and methods for the tanks' seismic design were summarized, then the tanks' dynamic pressure under horizontal and vertical earthquake excitation at the same time was analyzed theoretically, i. e. assuming the liquid in the tank is inviscid, irrotational and incompressible, and then to solve Laplace equation under given boundary conditions and make the tank wall' s pressure meet the Bernoulli equation; having the inertial force, uncoupling pulse pressure caused by storage tank vibration and the convection pressure from the liquid shaking respectively considered and the superposition principle based to get analytic e-quation of the dynamic pressure storage tank.%概述了储罐在抗震设计问题上已经取得的研究成果和方法.继此研究成果之后,对同时受到水平和竖直地震激励作用下的储罐动压力进行理论分析.即假定储罐内的液体为无粘、无旋、不可压缩的理想液体,在给定的边界条件下求解拉普拉斯方程,并使得罐壁压力满足线性贝努力方程.分别考虑储罐惯性力、罐液藕连振动产生的脉冲压力以及液面晃动产生的对流压力等各部分产生的压力,最后由叠加原理得到储罐动压力的解析表达式.

  9. Short communication: effect of storage and preservation on total bacterial counts determined by automated flow cytometry in bulk tank goat milk.

    Science.gov (United States)

    Sierra, D; Sánchez, A; Contreras, A; Luengo, C; Corrales, J C; de la Fe, C; Guirao, I; Morales, C T; Gonzalo, C

    2009-10-01

    This study was designed to evaluate the effects of different storage conditions on total bacterial count (TBC) determinations made in goat bulk tank milk using an automated flow cytometry method. The storage conditions tested were storage temperature (refrigeration at 4 and 10 degrees C or freezing at -20 degrees C), the use of a preservative (no preservative, NP; azidiol, AZ; or bronopol, BR), and the age of the milk samples for each analytical condition (storage times at 4 degrees C: from 0 h to 5 d for NP; and from 0 h to 22 d for AZ and BR; storage times at 10 degrees C: from 24 h to 2 d for NP and from 24 h to 22 for AZ and BR; storage times at -20 degrees C: from 24 h to 22 d for NP, AZ, and BR). Significant effects on individual bacterial count (IBC) variation were shown by the bulk tank milk sample, preservative, storage temperature, interaction preservative x storage temperature, and milk age within the interaction preservative x storage temperature. In preserved samples, the highest IBC were obtained for AZ and the lowest counts were obtained in samples preserved with BR. Because of the variation in IBC recorded in BR-preserved samples, we recommend that BR should not be used for TBC determinations using the automated flow cytometry method. The NP samples stored at 4 and 10 degrees C showed significantly higher IBC at 24 h postcollection, also invalidating these analytical conditions for TBC analyses. The practical implications of our findings are that goat milk samples preserved with AZ and stored at 10 or 4 degrees C are appropriate for TBC by the BactoScan flow cytometry method for up to 24 h and 11 d postcollection, respectively.

  10. Safety in Operation and Management of Dimethyl Ether Storage Tanks%二甲醚储罐的安全运行及管理

    Institute of Scientific and Technical Information of China (English)

    王峰

    2011-01-01

    对二甲醚储罐区进行危险辨识及事故后果模拟分析.从安全风险和运行管理的角度,进一步阐述了加强管理、确保二甲醚储罐安全运行与管理的具体措施.%A simulation analysis is carried out of hazard identification and accident consequences in a dimethyl ether storage tank farm. From the point of safety risks and operation management further explanation is given of specific measures for intensification of management and assurance of safety operation and management of the dimethyl ether storage tanks.

  11. Successful field application of novel, non-silicone antifoam chemistries for high foaming heavy oil storage tanks in northern Alberta

    Energy Technology Data Exchange (ETDEWEB)

    Wylde, J.J. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Clariant Oil Services, Montreal, PQ (Canada)

    2008-10-15

    Heavy oil operators in northern Alberta have experienced production problems associated with foam formation in crude oil storage tanks. The foam could enter the transportation trucks and create separation problems in the process systems. Any antifoam used in the system could not contain silicone based polymers since these compounds affected the catalysts used in upgrading the crude oil and in the manufacture of asphalt. As such, there was a need to change the performance of the antifoam product. A phosphate ester and a salted amine were the previous incumbent antifoam products that did not perform well. Several chemistries were tested, including phosphate based products; ethoxylated and propoxylated esters; polyethylene glycol esters and oleates; alcohols, fatty alcohols and ethoxylated; and propoxylated alcohols. All products had to be freeze protected to -40 degrees C, which influenced the efficacy of antifoam chemicals. This paper described how laboratory testing has evolved to field wide implementation of a combined defoamer/antifoam chemistry. The laboratory tests revealed that foam induced in heavy, aged crude was very challenging and required the addition of heptane to create the foam. A potential follow-up may be to induce the foam without the addition of heptane by using a Seltzer cylinder in a semi-quantitative manner to rank performance of products against one another. The final selection of antifoam will depend on supply chain cost since the performance of the 2 blend products was essentially the same. 12 refs., 7 figs.

  12. LNG Bunkering Operations: Establish probabilistic safety distances for LNG bunkering operations.

    OpenAIRE

    Arnet, Nora Marie Lundevall

    2014-01-01

    The environmental and economical advantages of using LNG as marine fuel have been recognized by the industry. In response to increasing demand, construction of LNG bunkering infrastructure is under rapid development. Several ports are preparing to supply LNG, but uncertainties concerning the bunkering process and operational safety still exist. Recently, much work has been done to standardize LNG bunkering solutions, including a launch of an ISO guideline and a Recommended Practice (RP) by DN...

  13. LNG Bunkering Operations: Establish probabilistic safety distances for LNG bunkering operations.

    OpenAIRE

    2014-01-01

    The environmental and economical advantages of using LNG as marine fuel have been recognized by the industry. In response to increasing demand, construction of LNG bunkering infrastructure is under rapid development. Several ports are preparing to supply LNG, but uncertainties concerning the bunkering process and operational safety still exist. Recently, much work has been done to standardize LNG bunkering solutions, including a launch of an ISO guideline and a Recommended Practice (RP) by DN...

  14. 2000 m3大型钢制球罐的应力分析%Stress Analysis of 2000m3 Large Steel Storage Tank

    Institute of Scientific and Technical Information of China (English)

    李建奎; 刘峰; 刘娟; 付路路

    2015-01-01

    The static load stress analysis of steel storage tank was carried out with the finite element software, the cloud of stress and strain overall structure of the tank were obtained after applying static load and displacement constraints, and the strength assessment was carried out according to JB 4732-1995 steel pressure vessel analysis and design standards and GB12337-1998 steel spherical tanks. The results show that the overall structure of the tank is reliable. The available databases provide reliable academic value for the optimization and design of the subsequent large tank.%应用有限元软件对钢制球罐进行了静载应力分析,施加位移约束和静载荷之后,得到了球罐整体结构的应力及应变云图,并依据JB 4732-1995《钢制压力容器分析设计标准》,参照GB12337—1998《钢制球形储罐》对其进行了强度评定,结果表明该结构是可靠的。分析出的数据库为以后球罐的优化设计提供了可靠的理论价值。

  15. 中低压储罐疲劳分析的免除%Exemption from Fatigue Analysis for Low- & Medium-Pressure Storage Tanks

    Institute of Scientific and Technical Information of China (English)

    刘晓敏

    2014-01-01

    以承受压力波动幅值0.4 MPa的充液罐为例,探讨采用整体补强和补强圈补强两种结构时免除疲劳分析的条件,并按照载荷分析、结构分析、应力分析和强度判定的设计过程,从经济性和安全性两方面,对比两种结构的优缺点及适用范围,为此类承受压力循环载荷的中低压储罐疲劳分析的免除提供参考。%The paper takes a filling tank with pressure fluctuation of 0.4 MPa for example to discuss the exemption condition of fatigue analysis for both the tank with integral reinforcement and the tank with reinforceing pad. The advantage and disadvantage as well as application range of the two type tanks are compared from the aspects of economy and safety on the basis of load analysis, structural analysis, stress analysis and strength determination to provide the reference for the fatigue analysis exemption for low-and medium-pressure storage tanks that bear cyclic pressure load.

  16. Deformation Control of Liquefied Natural Gas Storage Tank%液化天然气储罐制造中的变形控制

    Institute of Scientific and Technical Information of China (English)

    贾乃刚

    2012-01-01

    论述了液化天然气储罐制造中引起变形的因素,对预制阶段和焊接过程中的变形及防变形控制进行了简要介绍.%The factors that cause deformation in the liquefied natural gas storage tank manufacturing are discussed, deformation in prefabricated stage and welding process and anti-distortion control are introduced briefly.

  17. Addendum to the Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 134: Aboveground Storage Tanks, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Restoration

    2008-09-01

    The following is an addendum to the Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 134: Aboveground Storage Tanks, Nevada Test Site, Nevada, DOE/NV--1275, dated May 2008. This addendum expands upon information provided in the May 2008 plan. It provides specific details regarding samples to be collected at Corrective Action Sites 15-01-05 and 29-01-01. It also provides discussion and rationale for establishing the spatial boundaries of Corrective Action Sites.

  18. Results of the evaluation and preliminary validation of a primary LNG mass flow standard

    Science.gov (United States)

    van der Beek, Mijndert; Lucas, Peter; Kerkhof, Oswin; Mirzaei, Maria; Blom, Gerard

    2014-10-01

    LNG custody transfer measurements at large terminals have been based on ship tank level gauging for more than 50 years. Flow meter application has mainly been limited to process control in spite of the promise of simplified operations, potentially smaller uncertainties and better control over the measurements for buyers. The reason for this has been the lack of LNG flow calibration standards as well as written standards. In the framework of the EMRP1 ‘Metrology for LNG’ project, Van Swinden Laboratory (VSL) has developed a primary LNG mass flow standard. This standard is so far the only one in the world except for a liquid nitrogen flow standard at the National Institute of Standards and Technology (NIST). The VSL standard is based on weighing and holds a Calibration and Measurement Capability (CMC) of 0.12% to 0.15%. This paper discusses the measurement principle, results of the uncertainty validation with LNG and the differences between water and LNG calibration results of four Coriolis mass flow meters. Most of the calibrated meters do not comply with their respective accuracy claims. Recommendations for further improvement of the measurement uncertainty will also be discussed.

  19. Analysis on a cracking accident of hydrochloric acid storage tank caused by vacuum%稀盐酸储槽抽裂事故的分析

    Institute of Scientific and Technical Information of China (English)

    王欣荣

    2012-01-01

    分析了盐酸脱吸工序中稀盐酸储槽抽裂事故产生的原因;通过稀盐酸储槽的压力式液位计DCS历史曲线记录来间接分析稀盐酸储槽内压力变化情况,剖析负压的形成过程。结果表明:脱吸塔产生较大的负压是因为系统急停、温度下降后在略低于盐酸溶液恒沸点时发生冷凝相变而引起的。%Reasons for a cracking accident of hydrochloric acid storage tank caused by vacuum in hydrochloric acid desorption process were analyzed. Pressure changes inside dilute hydrochloric acid storage tank were indirectly analyzed according to DCS historical graph record of the pressure type level meter for the hydrochloric acid storage tank, and the negative pressure formation process was also discussed. The results showed that the formation of large negative pressure in desorption col- umn was caused by phase transition of condensation occurred whlie the temperature of system was a little less than the constant boiling point of hydrochloric acid solution, which was caused by emer- gency shutdown of system and temperature falling.

  20. A 400,000 lb crude oil storage tank was moved on an 11 in. air blanket

    Energy Technology Data Exchange (ETDEWEB)

    1979-03-01

    The British patented-system used to move the 55,000 bbl tank at the Cushing, Okla., tank farm of Getty Oil Co. uses the same airlift principle employed by various hovercraft. Representatives from 20 pipeline and oil companies watched the move, which placed the tank 22 ft higher and 600 ft away from its former location, to improve its gravity flow rate, an improvement spurred by greater crude demands placed on Cushing Terminal. Two 425 hp air compressors were attached to the tank's shell and produced 130,000 cu ft/min of air. The airflow was directed beneath the tank through a segmented skirt fixed to the circumference of the tank's base. Less than 0.5 psi air pressure across the tank floor was needed to lift the tank. Four large D-7 tractors pulled and guided the tank up the incline onto its new pad, where the vessel was rotated into alignment for piping connections. Preliminary rig-up, grading, and pad preparation took six days, but actual tank relocation required only two hours. Getty's Cushing terminal feeds to the 20 in. dia Osage pipeline that serves Getty's El Dorado, Kans., refinery as well as other carriers.

  1. HK to Benefit from Imported LNG Project

    Institute of Scientific and Technical Information of China (English)

    Yao Jianjun

    2002-01-01

    @@ Hong Kong is expected to buy one third of the mainland's US$ 10 billion worth of imported liquefied natural gas (LNG) to satisfy its growing energy demand, Mark Qiu, chief financial officer of CNOOC, said recently. He added Hong Kong will buy 1 million tons of LNG a year from the mainland's first LNG terminal in southern Guangdong Province to fuel the power plants and household consumption in the region.

  2. Fatigue reliability for LNG carrier

    Institute of Scientific and Technical Information of China (English)

    Xiao Taoyun; Zhang Qin; Jin Wulei; Xu Shuai

    2011-01-01

    The procedure of reliability-based fatigue analysis of liquefied natural gas (LNG) carrier of membrane type under wave loads is presented. The stress responses of the hotspots in regular waves with different wave heading angles and wave lengths are evaluated by global ship finite element method (FEM). Based on the probabilistic distribution function of hotspots' short-term stress-range using spectral-based analysis, Weibull distribution is adopted and discussed for fitting the long-term probabilistic distribution of stress-range. Based on linear cumulative damage theory, fatigue damage is characterized by an S-N relationship, and limit state function is established. Structural fatigue damage behavior of several typical hotspots of LNG middle ship section is clarified and reliability analysis is performed. It is believed that the presented results and conclusions can be of use in calibration for practical design and initial fatigue safety evaluation for membrane type LNG carrier.

  3. AX Tank Farm tank removal study

    Energy Technology Data Exchange (ETDEWEB)

    SKELLY, W.A.

    1998-10-14

    This report considers the feasibility of exposing, demolishing, and removing underground storage tanks from the 241-AX Tank Farm at the Hanford Site. For the study, it was assumed that the tanks would each contain 360 ft{sup 3} of residual waste (corresponding to the one percent residual Inventory target cited in the Tri-Party Agreement) at the time of demolition. The 241-AX Tank Farm is being employed as a ''strawman'' in engineering studies evaluating clean and landfill closure options for Hanford single-shell tank farms. The report is one of several reports being prepared for use by the Hanford Tanks Initiative Project to explore potential closure options and to develop retrieval performance evaluation criteria for tank farms.

  4. AX Tank Farm tank removal study

    Energy Technology Data Exchange (ETDEWEB)

    SKELLY, W.A.

    1998-10-14

    This report considers the feasibility of exposing, demolishing, and removing underground storage tanks from the 241-AX Tank Farm at the Hanford Site. For the study, it was assumed that the tanks would each contain 360 ft{sup 3} of residual waste (corresponding to the one percent residual Inventory target cited in the Tri-Party Agreement) at the time of demolition. The 241-AX Tank Farm is being employed as a ''strawman'' in engineering studies evaluating clean and landfill closure options for Hanford single-shell tank farms. The report is one of several reports being prepared for use by the Hanford Tanks Initiative Project to explore potential closure options and to develop retrieval performance evaluation criteria for tank farms.

  5. ECOLO-HOUSE in the heavy snow-fall region. Ground-water and wasted-wood become resources by utilizing storage-tank; Yukiguni ECOLO-HOUSE. Chikunetsuso wo riyoshita chikasui oyobi mokushitsu gomi no shigenka

    Energy Technology Data Exchange (ETDEWEB)

    Umemiya, H.; Fukumuro, S. [Yamagata University, Yamagata (Japan)

    1997-11-25

    This paper reports living comfort in summer by operating a groundwater utilization system using a hot water storage tank and a floor air conditioning system. The groundwater utilization system is a system for room cooling by using groundwater and for supplying water for living use. The system operates as follows: groundwater is passed through a coil-type heat exchanger having pipes each 100 m long laid in parallel for a total length of 200 m, the heat exchanger being installed in a hot water storage tank; the water is used to cool water in the storage tank in summer; and the water is warmed up in the storage tank in winter, further heated by an oil boiler to be used as hot water for cooking and bathing. In the floor air conditioning system, cold water in the water storage tank (warm water in winter) is pumped up by a circulation pump, and passed through the floor air conditioning circuit having a pipe with a total length of 400 m at a flow rate of 14 liters per minute. The system is of a closed circuit in which the water is re-heated by a wood burning boiler in winter and returned to the hot water storage tank. The amount of supplied cold heat from groundwater to the hot water tank obtained on a daily average is 90W. About 20% of the monthly cumulative cold heat amount dissipated from the floor circuit is the monthly cumulative cold heat amount supplied from the groundwater circuit to the hot water storage tank. 1 ref., 10 figs., 1 tab.

  6. Thermodynamic Processes Involving Liquefied Natural Gas at the LNG Receiving Terminals / Procesy termodynamiczne z wykorzystaniem skroplonego gazu ziemnego w terminalach odbiorczych LNG

    Science.gov (United States)

    Łaciak, Mariusz

    2013-06-01

    The increase in demand for natural gas in the world, cause that the production of liquefied natural gas (LNG) and in consequences its regasification becoming more common process related to its transportation. Liquefied gas is transported in the tanks at a temperature of about 111K at atmospheric pressure. The process required to convert LNG from a liquid to a gas phase for further pipeline transport, allows the use of exergy of LNG to various applications, including for electricity generation. Exergy analysis is a well known technique for analyzing irreversible losses in a separate process. It allows to specify the distribution, the source and size of the irreversible losses in energy systems, and thus provide guidelines for energy efficiency. Because both the LNG regasification and liquefaction of natural gas are energy intensive, exergy analysis process is essential for designing highly efficient cryogenic installations. Wzrost zapotrzebowania na gaz ziemny na świecie powoduje, że produkcja skroplonego gazu ziemnego (LNG), a w konsekwencji jego regazyfikacja, staje się coraz bardziej powszechnym procesem związanym z jego transportem. Skroplony gaz transportowany jest w zbiornikach w temperaturze około 111K pod ciśnieniem atmosferycznym. Przebieg procesu regazyfikacji niezbędny do zamiany LNG z fazy ciekłej w gazową dla dalszego transportu w sieci, umożliwia wykorzystanie egzergii LNG do różnych zastosowań, między innymi do produkcji energii elektrycznej. Analiza egzergii jest znaną techniką analizowania nieodwracalnych strat w wydzielonym procesie. Pozwala na określenie dystrybucji, źródła i wielkości nieodwracalnych strat w systemach energetycznych, a więc ustalić wytyczne dotyczące efektywnego zużycia energii. Ponieważ zarówno regazyfikacja LNG jak i skraplanie gazu ziemnego są energochłonne, proces analizy egzergii jest niezbędny do projektowania wysoce wydajnych instalacji kriogenicznych.

  7. A Calculation Method for the Sloshing Impact Pressure Imposed on the Roof of a Passive Water Storage Tank of AP1000

    Directory of Open Access Journals (Sweden)

    Daogang Lu

    2016-01-01

    Full Text Available There is a large water storage tank installed at the top of containment of AP1000, which can supply the passive cooling. In the extreme condition, sloshing of the free surface in the tank may impact on the roof under long-period earthquake. For the safety assessment of structure, it is necessary to calculate the impact pressure caused by water sloshing. Since the behavior of sloshing impacted on the roof is involved into a strong nonlinear phenomenon, it is a little difficult to calculate such pressure by theoretical or numerical method currently. But it is applicable to calculate the height of sloshing in a tank without roof. In the present paper, a simplified method was proposed to calculate the impact pressure using the sloshing wave height, in which we first marked the position of the height of roof, then produced sloshing in the tank without roof and recorded the maximum wave height, and finally regarded approximately the difference between maximum wave height and roof height as the impact pressure head. We also designed an experiment to verify this method. The experimental result showed that this method overpredicted the impact pressure with a certain error of no more than 35%. By the experiment, we conclude that this method is conservative and applicable for the engineering design.

  8. Design and operation of an aluminium alloy tank using doped Na3AlH6 in kg scale for hydrogen storage

    Science.gov (United States)

    Urbanczyk, R.; Peinecke, K.; Meggouh, M.; Minne, P.; Peil, S.; Bathen, D.; Felderhoff, M.

    2016-08-01

    In this publication the authors present an aluminium alloy tank for hydrogen storage using 1921 g of Na3AlH6 doped with 4 mol% of TiCl3 and 8 mol% of activated carbon. The tank and the heat exchangers are manufactured by extrusion moulding of Al-Mg-Si based alloys. EN AW 6082 T6 alloy is used for the tank and a specifically developed alloy with a composition similar to EN AW 6060 T6 is used for the heat exchangers. The three heat exchangers have a corrugated profile to enhance the surface area for heat transfer. The doped complex hydride Na3AlH6 is densified to a powder density of 0.62 g cm-3. The hydrogenation experiments are carried out at 2.5 MPa. During one of the dehydrogenation experiments approximately 38 g of hydrogen is released, accounting for gravimetric hydrogen density of 2.0 mass-%. With this tank 15 hydrogenation and 16 dehydrogenation tests are carried out.

  9. REPAIR SUMMARY OF LARGE LIQUID AMMONIA STORAGE TANK%大型液氨储罐检修过程综述

    Institute of Scientific and Technical Information of China (English)

    李大伟

    2012-01-01

    large liquid ammonia storage tank is of a special equipment with highly source of danger and big safety risk existed during the repair, The company has successfully conducted the repair work of theammonia tank with a series of measures including careful organization, draw-up of scheme, risk evaluation and safety management and control and a safe running of the tank is ensured.This complete set of operation regulations and work criteria for the tank repair has formulated and provided valuable experiences for the like.%大型液氨储罐是高危险源特种设备,检修安全风险大。经过周密组织、方案编写、风险评估、安全管控等一系列措施,成功进行了氨罐检修工作,保障了氨罐的安全运行,形成一套完整的氨罐检修操作规程及工作标准。

  10. Streamlined Approach for Environmental Restoration Closure Report for Corrective Action Unit 120: Areas 5 and 6 Aboveground Storage Tanks, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Allison Urban

    1999-06-01

    This Closure Report provides documentation for the closure of Corrective Action Unit 120. CAU 120 consists of two Corrective Action Sites located in Areas 5 and 6 of the Nevada Test Site. CAS 05-01-01 is located in Area 5 and consists of three 45,800-liter aboveground storage tanks, piping, and debris associated with Well RNM-1. CAS 06-01-01 in Area 6 consists of two aboveground storage tanks and two tanker trailers All the CAU 120 items have been used to convey or contain radiologically contaminated fluid from post-nuclear event activities at the NTS> Closure of this CAU was completed by collecting samples to identify the appropriate method of disposal for tanks, piping, debris, and tankers in each CAS. Placing low-level radioactive waste into the appropriate containers and disposing of waste in the Area 5 Radioactive Waste Management Site, the Area 9 10C Landfill, and the Area 3 Radioactive Waste Management Site.

  11. Work plan and health and safety plan for Building 3019B underground storage tank at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Burman, S.N.; Brown, K.S.; Landguth, D.C.

    1992-08-01

    As part of the Underground Storage Tank Program at the Department of Energy's Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, this Health and Safety Plan has been developed for removal of the 110-gal leaded fuel underground storage tank (UST) located in the Building 3019B area at ORNL This Health and Safety Plan was developed by the Measurement Applications and Development Group of the Health and Safety Research Division at ORNL The major components of the plan follow: (1) A project description that gives the scope and objectives of the 110-gal tank removal project and assigns responsibilities, in addition to providing emergency information for situations occurring during field operations; (2) a health and safety plan in Sect. 15 for the Building 3019B UST activities, which describes general site hazards and particular hazards associated with specific tasks, personnel protection requirements and mandatory safety procedures; and (3) discussion of the proper form completion and reporting requirements during removal of the UST. This document addresses Occupational Safety and Health Administration (OSHA) requirements in 29 CFR 1910.120 with respect to all aspects of health and safety involved in a UST removal. In addition, the plan follows the Environmental Protection Agency (EPA) QAMS 005/80 (1980) format with the inclusion of the health and safety section (Sect. 15).

  12. Work plan and health and safety plan for Building 3019B underground storage tank at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Burman, S.N.; Brown, K.S.; Landguth, D.C.

    1992-08-01

    As part of the Underground Storage Tank Program at the Department of Energy`s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, this Health and Safety Plan has been developed for removal of the 110-gal leaded fuel underground storage tank (UST) located in the Building 3019B area at ORNL This Health and Safety Plan was developed by the Measurement Applications and Development Group of the Health and Safety Research Division at ORNL The major components of the plan follow: (1) A project description that gives the scope and objectives of the 110-gal tank removal project and assigns responsibilities, in addition to providing emergency information for situations occurring during field operations; (2) a health and safety plan in Sect. 15 for the Building 3019B UST activities, which describes general site hazards and particular hazards associated with specific tasks, personnel protection requirements and mandatory safety procedures; and (3) discussion of the proper form completion and reporting requirements during removal of the UST. This document addresses Occupational Safety and Health Administration (OSHA) requirements in 29 CFR 1910.120 with respect to all aspects of health and safety involved in a UST removal. In addition, the plan follows the Environmental Protection Agency (EPA) QAMS 005/80 (1980) format with the inclusion of the health and safety section (Sect. 15).

  13. Guidance on risk analysis and safety implications of a large liquefied natural gas (LNG) spill over water.

    Energy Technology Data Exchange (ETDEWEB)

    Wellman, Gerald William; Melof, Brian Matthew; Luketa-Hanlin, Anay Josephine; Hightower, Marion Michael; Covan, John Morgan; Gritzo, Louis Alan; Irwin, Michael James; Kaneshige, Michael Jiro; Morrow, Charles W.

    2004-12-01

    While recognized standards exist for the systematic safety analysis of potential spills or releases from LNG (Liquefied Natural Gas) storage terminals and facilities on land, no equivalent set of standards or guidance exists for the evaluation of the safety or consequences from LNG spills over water. Heightened security awareness and energy surety issues have increased industry's and the public's attention to these activities. The report reviews several existing studies of LNG spills with respect to their assumptions, inputs, models, and experimental data. Based on this review and further analysis, the report provides guidance on the appropriateness of models, assumptions, and risk management to address public safety and property relative to a potential LNG spill over water.

  14. 33 CFR 127.321 - Release of LNG.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Release of LNG. 127.321 Section... Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.321 Release of LNG. (a) The operator of the waterfront facility handling LNG shall ensure that— (1) No person releases LNG into the...

  15. 78 FR 41047 - UGI LNG, Inc.; Notice of Application

    Science.gov (United States)

    2013-07-09

    ... Energy Regulatory Commission UGI LNG, Inc.; Notice of Application On June 17, 2013, UGI LNG, Inc. (UGI LNG) filed a request pursuant to section 7(c) of the Natural Gas Act, and Part 157 of the Rules and Regulations of the Commission. UGI LNG seeks authorization to construct additional refrigeration capacity...

  16. Calculation and analysis on safe distance of pool fire from storage tank%储罐池火安全距离计算分析

    Institute of Scientific and Technical Information of China (English)

    李果

    2015-01-01

    The thermal radiation of pool fire of storage tank is calculated by software simulation,which is based on Mudan calculation.The safe distance of equipment and personnel are established in accordance with damage criteria of thermal radiation, which will be helpful for accidents rescue and layout of tanks and other facilities.%基于Mudan计算法,运用软件模拟计算储罐池火灾的热辐射影响范围,根据热辐射破坏准则得出设备和人员的安全距离,为站场储罐与其他工艺装置设备间距布置、事故救援提供参考依据.

  17. Application of a temperature selective storage tank solar system. Part 4. Fundamental experiment under a solar simulator; Ondo sentaku chikunetsuso no solar system eno tekiyo. 4. Solar simulator ni yoru kiso jikken

    Energy Technology Data Exchange (ETDEWEB)

    Kanayama, K.; Endo, N.; Baba, H.; Okamoto, A. [Kitami Institute of Technology, Hokkaido (Japan); Kamiya, Y. [Kanto Gakuin University, Yokohama (Japan)

    1996-10-27

    The storage tank is classified into a mixed type and stratified type. The stratified type is judged to be more advantageous from a viewpoint of the effective energy utilization. An experiment was made using a solar simulator to put the system, consisting of a vacuum double-glass tube collector and temperature selective storage tank, to practical use. The ejection position of the storage tank at the top is superior to that at the bottom, in the 60{degree}C layer of three layers (60, 40, and 20{degree}C). The ejection position hardly varies with the shape (straight or elbow) of an ejection port. When the temperature stratified layer is formed in two layers (40 {times} 2, 20{degree}C) to three layers (60, 40, and 20{degree}C), heat can be stably stored as the flow rate is higher. The stratified storage tank is inferior to the mixed storage tank in heat collection efficiency, but the specific exergy increases. By increasing the number of heat storage layers, the result of this experiment can also be applied to the linear temperature gradient layer obtained in the practical use. As a result of the above experiment, the basic data for an automated system design during practical application was obtained. 3 refs., 15 figs.

  18. 76 FR 2677 - Southern LNG Company, LLC; Notice of Public Scoping Meeting for the Proposed LNG Truck Loading...

    Science.gov (United States)

    2011-01-14

    ... Energy Regulatory Commission Southern LNG Company, LLC; Notice of Public Scoping Meeting for the Proposed LNG Truck Loading Project January 7, 2011. On February 2, 2011, the Office of Energy Projects staff... Southern LNG Company, LLC's (Southern) LNG Truck Loading Project. We scheduled this meeting to...

  19. Fragility Analysis Methodology for Degraded Structures and Passive Components in Nuclear Power Plants - Illustrated using a Condensate Storage Tank

    Energy Technology Data Exchange (ETDEWEB)

    Nie, J.; Braverman, J.; Hofmayer, C.; Choun, Y.; Kim, M.; Choi, I.

    2010-06-30

    determined to be risk significant to NPPs. Multiple models have been identified for concrete, carbon and low-alloy steel, and stainless steel. These models are documented in the Annual Report for the Year 2 Task, identified as BNL Report-82249-2009 and also designated as KAERI/TR-3757/2009. This report describes the research effort performed by BNL for the Year 3 scope of work. The objective is for BNL to develop the seismic fragility capacity for a condensate storage tank with various degradation scenarios. The conservative deterministic failure margin method has been utilized for the undegraded case and has been modified to accommodate the degraded cases. A total of five seismic fragility analysis cases have been described: (1) undegraded case, (2) degraded stainless tank shell, (3) degraded anchor bolts, (4) anchorage concrete cracking, and (5)a perfect combination of the three degradation scenarios. Insights from these fragility analyses are also presented.

  20. Hydrogen Storage Tank

    CERN Multimedia

    1983-01-01

    This huge stainless steel reservoir,placed near an end of the East Hall, was part of the safety equipment connected to the 2 Metre liquid hydrogen Bubble Chamber. It could store all the hydrogen in case of an emergency. The picture shows the start of its demolition.

  1. Accelerated safety analyses - structural analyses Phase I - structural sensitivity evaluation of single- and double-shell waste storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Becker, D.L.

    1994-11-01

    Accelerated Safety Analyses - Phase I (ASA-Phase I) have been conducted to assess the appropriateness of existing tank farm operational controls and/or limits as now stipulated in the Operational Safety Requirements (OSRs) and Operating Specification Documents, and to establish a technical basis for the waste tank operating safety envelope. Structural sensitivity analyses were performed to assess the response of the different waste tank configurations to variations in loading conditions, uncertainties in loading parameters, and uncertainties in material characteristics. Extensive documentation of the sensitivity analyses conducted and results obtained are provided in the detailed ASA-Phase I report, Structural Sensitivity Evaluation of Single- and Double-Shell Waste Tanks for Accelerated Safety Analysis - Phase I. This document provides a summary of the accelerated safety analyses sensitivity evaluations and the resulting findings.

  2. Heat release performance of heat storage water tank with phase-change material in solar drying system%太阳能干燥相变储热水箱的放热性能

    Institute of Scientific and Technical Information of China (English)

    于海涛; 高建民; 陈瑶

    2015-01-01

    为降低传统干燥能耗,强化太阳能干燥用储热水箱的储放热能力,在普通储热水箱中添加了硬脂酸/膨胀石墨相变储热材料,研究了放热温差、储热单元体积对装置放热性能的影响。研究结果表明:相变储热水箱放热时间、放热量随着放热温差和储热水箱中储热单元体积的增加均有所提升,储热单元的添加对储热水箱的放热效果影响更为显著。放热效率则随着放热温差的增大而降低,随着储热水箱中储热单元体积的增加而显著提升;储热水箱中储热单元体积为35%时,相变储热水箱的放热时间比普通储热水箱最多提升了1.26倍,放热温度最大可提高8.7℃,热效率最多可提高22.56%。%Drying is an essential process for a large number of industrial and agricultural products. In order to reduce energy consumption of traditional drying, improve its utilization efficiency and strengthen the capacity of heat storage water tank for solar drying, the stearic acid/expanded graphite composite phase-change material (PCM) with melting point of 52.74℃ and latent heat of 169.90 J/g was added into the conventional heat storage water tank in this paper. The schematic structure of the solar drying system mainly consisted of solar collector, drying oven, heat storage water tank and phase-change thermal energy storage units. The effect of heat release temperature difference and heat storage unit volume on the heat release performance of the device was studied under the same heat release conditions. The total volume of the PCM containers in the heat storage water tank was 15%, 25% and 35%, respectively. The heat storage water tank was heated to 60, 65 and 75℃ by using solar collector in heat storage process. Then the heat storage water tank was used to provide heat for the drying oven, and the heat release process was finished when the temperature of drying oven was 40℃ . The results showed that the

  3. Modeling potential occupational inhalation exposures and associated risks of toxic organics from chemical storage tanks used in hydraulic fracturing using AERMOD.

    Science.gov (United States)

    Chen, Huan; Carter, Kimberly E

    2017-05-01

    Various toxic chemicals used in hydraulic fracturing fluids may influence the inherent health risks associated with these operations. This study investigated the possible occupational inhalation exposures and potential risks related to the volatile organic compounds (VOCs) from chemical storage tanks and flowback pits used in hydraulic fracturing. Potential risks were evaluated based on radial distances between 5 m and 180 m from the wells for 23 contaminants with known inhalation reference concentration (RfC) or inhalation unit risks (IUR). Results show that chemicals used in 12.4% of the wells posed a potential acute non-cancer risks for exposure and 0.11% of the wells with may provide chronic non-cancer risks for exposure. Chemicals used in 7.5% of the wells were associated with potential acute cancer risks for exposure. Those chemicals used in 5.8% of the wells may be linked to chronic cancer risks for exposure. While eight organic compounds were associated with acute non-cancer risks for exposure (>1), methanol the major compound in the chemical storage tanks (1.00-45.49) in 7,282 hydraulic fracturing wells. Wells with chemicals additives containing formaldehyde exhibited both acute and chronic cancer risks for exposure with IUR greater than 10(-6), suggesting formaldehyde was the dominant contributor to both types of risks for exposure in hydraulic fracturing. This study also found that due to other existing on-site emission sources of VOCs and the geographically compounded air concentrations from other surrounding wells, chemical emissions data from storage tanks and flowback pits used in this study were lower than reported concentrations from field measurements where higher occupational inhalation risks for exposure may be expected.

  4. 某10万m3钢储罐罐体变形的修复措施%The Rectification Methodof 100,000 m3 Steel Oil Storage Tank Wall Deformation

    Institute of Scientific and Technical Information of China (English)

    应付钊; 丁伟

    2013-01-01

    The differential settlement of tank foundation or low quality tank erection will cause wall deformation of steel oil storage tank, the low quality tank erection will have greater effect on the lifting of floating roof than the differential settlement of tank foundation. In the paper, the reason causing wall deformation and rectification method were introduced, some questions that need considered during steel oil storage tank erection and high pressure filling method of cavity which is between tank bottom plate and tank foundation were pointed. Finally, some referable conclusions are obtained.%地基不均匀沉降和安装不当均会引起钢储罐罐体变形,安装不当引起的罐体变形比罐基础不均匀沉降造成的罐体变形对浮船升降影响可能更大.通过对某10万m3钢储罐产生罐壁变形的原因分析和纠偏措施介绍,提出了一些大型储罐在安装过程中应注意的问题,给出了罐体顶升后间隙采用高压吹填的处理措施,对同类工程设计有一定的借鉴意义.

  5. Application of liquid level meter in ammonia storage tank%液氨储罐液位测量仪表的应用分析

    Institute of Scientific and Technical Information of China (English)

    王之忠

    2016-01-01

    本文对差压变送器、磁翻板液位计和缆式导波雷达液位计这三种液氨储罐液位测量仪表的应用问题展开了分析,从而为关注这一话题的人们提供参考。%This article presents the application of cable guide wave radar gauge, differential pressure transmitter, and magnetism vane liquid meter in ammonia storage tank for reference.

  6. DAMPAK LNG ACADEMY TERHADAP KESIAPAN TENAGA KERJA BARU DI BADAK LNG

    Directory of Open Access Journals (Sweden)

    Busori Sunaryo

    2015-03-01

    Full Text Available LNG Academy diharapkan mampu menghasilkan individu yang memiliki kemampuan tinggi dan bisa memadukan antara pendidikan dan dunia industri. Hal ini juga mendukung program pemerintah dalam mengurangi tingkat pengangguran, terutama lulusan perguruan tinggi. Program management trainee di Badak LNG, lulusan dari LNG academy menbutuhkan waktu 6 bulan untuk melalui tahap pelatihan kerja serta pelatihan kerja khusus. Sedangkan lulusan program MT di luar LNG academy biasanya membutuhkan waktu 18 bulan untuk melalui masa training. Artinya ini akan menghemat 12 bulan. Sejak kelar perdana di kampus, siswa sudah diperkenalkan dengan lingkungan kerja pada perusahaan gas alam. Oleh karena itu, lulusan LNG academy yang bekerja di Badak LNG tidak menemukan kesulitan berarti saat beradaptasi dengan lingkungan kerja. Dalam jangka pendek mereka dapat langsung siap bekerja dan mengetahui betapa strategis dampak dari bisnis gas alam cair dalam peta pembangunan nasional.LNG Academy is able to produce individuals (output who have a considerably high link and match between education and industrial world. It also supports the governmental programs in reducing unemployment rates, especially the individuals graduated from university. It can also overcome the issue related to duration. Badak LNG Management Trainees, graduated from LNG Academy class, need only 6 months to pass the On Job Training as well as Job Specific Training. Whereas the MT graduated from outside the LNG Academy usually need 18 months in order to pass the trainings. It means that there are 12 months which can be saved (outcome.  Since the early classes in the academy, the students have been introduced to the working ecosystem of the liquid natural gas company. Therefore, LNG Academy graduates who work for Badak LNG have no significant difficulty adapting with the working ecosystem, whether it is related to the working mechanism or other working cultures. In a short duration, they can be directly working

  7. 围堰对LNG储罐泄漏扩散规律影响研究%Research on Influences of Dike Dam on the Law of LNG Release and Dispersion

    Institute of Scientific and Technical Information of China (English)

    刘隆; 孟波; 王启

    2014-01-01

    The paper used the Fluent package and based on CFD modeling technique to study the law of LNG release and dispersion,and then simulated effects of size of dike dam and tank value on shape of the LNG dense gas and range of explo-sion.It showed that the dike dam can prevent the LNG dense gas by the inside,and shorter the dike dam can prevent more LNG dense gas than the longer dike dam.The research also discovered that the influence of dike dam on larger LNG tank is clearer than that on smaller LNG tank.The research can provide scientific guidelines for site of LNG receiving terminals, establishment of emergency response plan,delimitation of exclusion zones and evaluation and claims of hazard suffered from accidence.%利用流体力学软件FLUENT对围堰存在情况下的 LNG 储罐泄漏扩散进行了数值模拟,并对不同围堰尺寸和不同储罐容积条件下泄漏扩散的气云形态变化和爆炸范围进行了对比。结果表明,围堰可以有效地阻止气云的扩散,使气云聚集在围堰内侧;随着围堰长度的减小,对 LNG 储罐泄漏扩散阻挡作用越来越明显;围堰对大型LNG储罐泄漏扩散的阻挡较小型储罐更加明显。研究结果对指导 LNG安全储运、使用及事故后果控制具有重要意义。

  8. Research of design challenges and new technologies for floating LNG

    Science.gov (United States)

    Lee, Dong-Hyun; Ha, Mun-Keun; Kim, Soo-Young; Shin, Sung-Chul

    2014-06-01

    With the rate of worldwide LNG demand expected to grow faster than that of gas demand, most major oil companies are currently investing their resources to develop floating LNG-FLNG (i.e. LNG FSRU and LNG FPSO). The global Floating LNG (FLNG) market trend will be reviewed based on demand and supply chain relationships. Typical technical issues associated with FLNG design are categorized in terms of global performance evaluation. Although many proven technologies developed through LNG carrier and oil FPSO projects are available for FLNG design, we are still faced with several technical challenges to clear for successful FLNG projects. In this study, some of the challenges encountered during development of the floating LNG facility (i.e. LNG FPSO and FSRU) will be reviewed together with their investigated solution. At the same time, research of new LNG-related technologies such as combined containment system will be presented.

  9. Research of design challenges and new technologies for floating LNG

    Directory of Open Access Journals (Sweden)

    Lee Dong-Hyun

    2014-06-01

    Full Text Available With the rate of worldwide LNG demand expected to grow faster than that of gas demand, most major oil companies are currently investing their resources to develop floating LNG-FLNG (i.e. LNG FSRU and LNG FPSO. The global Floating LNG (FLNG market trend will be reviewed based on demand and supply chain relationships. Typical technical issues associated with FLNG design are categorized in terms of global performance evaluation. Although many proven technologies developed through LNG carrier and oil FPSO projects are available for FLNG design, we are still faced with several technical challenges to clear for successful FLNG projects. In this study, some of the challenges encountered during development of the floating LNG facility (i.e. LNG FPSO and FSRU will be reviewed together with their investigated solution. At the same time, research of new LNG-related technologies such as combined containment system will be presented.

  10. High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The Safeguards and Security (S&S) Functional Area address the programmatic and technical requirements, controls, and standards which assure compliance with applicable S&S laws and regulations. Numerous S&S responsibilities are performed on behalf of the Tank Farm Facility by site level organizations. Certain other responsibilities are shared, and the remainder are the sole responsibility of the Tank Farm Facility. This Requirements Identification Document describes a complete functional Safeguards and Security Program that is presumed to be the responsibility of the Tank Farm Facility. The following list identifies the programmatic elements in the S&S Functional Area: Program Management, Protection Program Scope and Evaluation, Personnel Security, Physical Security Systems, Protection Program Operations, Material Control and Accountability, Information Security, and Key Program Interfaces.

  11. An Assessment of Technologies to Provide Extended Sludge Retrieval from Underground Storage Tanks at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    JA Bamberger

    2000-08-02

    The purpose of this study was to identify sludge mobilization technologies that can be readily installed in double-shell tanks along with mixer pumps to augment mixer pump operation when mixer pumps do not adequately mobilize waste. The supplementary technologies will mobilize sludge that may accumulate in tank locations out-of-reach of the mixer-pump jet and move the sludge into the mixer-pump range of operation. The identified technologies will be evaluated to determine if their performances and configurations are adequate to meet requirements developed for enhanced sludge removal systems. The study proceeded in three parallel paths to identify technologies that: (1) have been previously deployed or demonstrated in radioactive waste tanks, (2) have been specifically evaluated for their ability to mobilize or dislodge waste simulants with physical and theological properties similar to those anticipated during waste retrieval, and (3) have been used in similar industrial conditions, bu t not specifically evaluated for radioactive waste retrieval.

  12. High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 5

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The Fire Protection functional area for the Hanford Site Tank Farm facilities and support structures is based on the application of relevant DOE orders, regulations, and industry codes and standards. The fire protection program defined in this document may be divided into three areas: (1) organizational, (2) administrative programmatic features, and (3) technical features. The information presented in each section is in the form of program elements and orders, regulations, industry codes, and standards that serve as the attributes of a fire protection program for the Tank Farm facilities. Upon completion this document will be utilized as the basis to evaluate compliance of the fire protection program being implemented for the Tank Farm facilities with the requirements of DOE orders and industry codes and standards.

  13. Study of thermocline development inside a dual-media storage tank at the beginning of dynamic processes

    Science.gov (United States)

    Esence, Thibaut; Bayón, Rocío; Bruch, Arnaud; Rojas, Esther

    2017-06-01

    This work presents some of the experimental results obtained during a test campaign performed at the STONE facility of CEA-Grenoble in collaboration with CIEMAT-PSA supported by both the SFERA-II and the STAGE-STE project. This installation consists of a thermocline tank with thermal oil and rock/sand filler and the tests aimed to study the development of the temperature profile inside the tank at the beginning of charge/discharge processes. The investigation of how this profile is created and which is its dependence on the experimental parameters is crucial for predicting the behavior of a dual-media thermocline tank. Tests have been performed for dynamic processes from initial states with constant uniform temperature or with a thermal gradient already present due to a partial thermocline zone extraction in the former process. Tests at different fluid velocities and temperatures have been carried out as well, in order to evaluate the influence of operating conditions. When a dynamic process of charge or discharge is started, the development of the thermal front is very sharp and localized at tank top or bottom if initial tank temperature is uniform, whereas it is less pronounced if the test begins from a non-thermally uniform initial state. In terms of operating conditions, it has been observed that the development of the thermocline thermal front is independent not only of the fluid velocity but also of its temperatures, within the working ranges here considered. Due to these experimental results, it will be possible to improve simulation models for thermocline tanks and hence to predict their behavior more accurately, especially when they are implemented in annual simulations of CSP plants.

  14. 大型液化天然气储气罐沉降分析%SETTLEMENT ANALYSIS ON LARGE LIQUEFIED NATURAL GAS STORAGE TANK

    Institute of Scientific and Technical Information of China (English)

    贺超; 杨建江

    2012-01-01

    随着我国天然气利用的不断增长,对大型液化天然气储气罐的研究显得越来越重要.本文介绍了Randolph和Worth提出的单桩及群桩基础沉降公式并结合Ansys有限元分析软件对高承台大型液化天然气储气罐进行沉降分析.Ansys模型分析得出的沉降结果与已有工程经验有很好的吻合.%With the growing use of natural gas, the study of large-scale liquefied natural gas storage tank is becoming increasingly important. This paper introduces the formula of single pile and group pile foundation settlement proposed by Randolph and Worth, and also analysis the settlement of the high cap foundation of the large-scale liquefied natural gas storage tank with Ansys finite element analysis software. The sedimentation results educed from Ansys model analysis are in good agreement with the existing engineering experience.

  15. ALGORITHM FOR THE CREATION OF THE WIREFRAME MODEL OF A FIXED ROOF FOR A FUEL STORAGE TANK IN FORM OF GEODESIC DOME

    Directory of Open Access Journals (Sweden)

    Yamill Santiago Campos Pérez

    2015-01-01

    Full Text Available A geodesic dome is a mesh of bars and nodes arranged along the edges and vertices of a polyhedron on a surface that can be in the form of a sphere, parabola or ellipse. From knowing the advantages of this type of structure, they have been widely used in various constructions such as: housing, commercial offices, greenhouses, fair stand, fixed ceilings fuel storage tanks, among others. Many researchers have studied modeling and geometry of geodesic domes. The purpose of this paper is to present, from the review and compilation of information from several researches, an algorithm for generating a wireframe model of a geodesic dome for fixed roofs of spherical fuel storage tanks, for a further analysis of resistance by the method of finite elements. In this paper, we describe in detail the procedure and geometric expressions that were used. Finally, a computer program was developed in order to evaluate mathematical expressions and the procedure described in this paper and also to have a tool for generating computational model of a geodesic dome.

  16. Effect of Interfacial Turbulence and Accommodation Coefficient on CFD Predictions of Pressurization and Pressure Control in Cryogenic Storage Tank

    Science.gov (United States)

    Kassemi, Mohammad; Kartuzova, Olga; Hylton, Sonya

    2015-01-01

    Laminar models agree closely with the pressure evolution and vapor phase temperature stratification but under-predict liquid temperatures. Turbulent SST k-w and k-e models under-predict the pressurization rate and extent of stratification in the vapor but represent liquid temperature distributions fairly well. These conclusions seem to equally apply to large cryogenic tank simulations as well as small scale simulant fluid pressurization cases. Appropriate turbulent models that represent both interfacial and bulk vapor phase turbulence with greater fidelity are needed. Application of LES models to the tank pressurization problem can serve as a starting point.

  17. LNG terminal location still a tossup

    Index Scriptorium Estoniae

    2011-01-01

    Lätti rajatava LNG terminali asukoht pole veel teada. 16. märtsil kohtus Poola president Bronislaw Komorowki Läti riigipea Valdis Zatlersiga ja kiitis selle projekti heaks. Venemaast energiasõltumatuse olulisusest

  18. Fundamental study on hydrogen storage with hydrogen absorbing alloys. Operating characteristics of storage tank; Suiso kyuzo gokin wo mochiita suiso chozo ni kansuru kiso kenkyu. Chozo yoki no dosa tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Sekiguchi, S.; Sekiguchi, N.; Tani, T. [Science University of Tokyo, Tokyo (Japan)

    1997-11-25

    Hydrogen absorption by a hydrogen storage (MH storage) is investigated for static characteristics, with a constant current applied to the hydrogen generator, and dynamic characteristics, with a fluctuating current applied to the same simulating actual insolation. In the experiment, alloy temperature (MH temperature) in the storage and a current for the generator are preset, and then automatic measurement is allowed to proceed at 10-second intervals of the differential pressure, hydrogen temperature in the piping, absolute pressure, MH temperature, room temperature, and water tank temperature. It is found as the result of the experiment that absorption performance is improved when the MH storage is cooled; that the mean absorption rate which is 1 without cooling increases to 1.62 at 7degC; that the mean absorption rate changes in proportion to the applied current (introduced hydrogen flow rate); that the rate which is 1 at 32A decreases to 0.53 that at 16A; that the absorption rate is dependent more on the current applied to the storage than the temperature of the heat exchanging medium; and that, even in the presence of fluctuation halfway in the applied current, the total absorption will be equal to a case of constant current application if the total amount of applied current is equal. 2 refs., 7 figs., 5 tabs.

  19. Progress and Prospect of LNG Cold Energy Utilization in China

    Institute of Scientific and Technical Information of China (English)

    Hua Ben

    2009-01-01

    @@ Values and utilization significance of LNG cold energy LNG is a cryogenic liquid mixture made from gas through purification and liquefaction at the temperature of 162℃.850 kWh/t of power may be consumed for LNG production.230kWh/t of cold energy with the temperature ranging from-162℃ to 5℃ may be released when LNG is gasified under the pressure of latm.During actual gasification operation,pumps are required to be used to increase pressure for LNG gasification and delivery,so part of LNG cold energy will be converted into pressure energy(Fig.1).

  20. LNG: a commodity in the making

    Energy Technology Data Exchange (ETDEWEB)

    Chabrelie, M.F

    2006-07-01

    Although still far from being a commodity, LNG is undoubtedly emerging as an essential vector for world gas expansion. The flexibility it procures in terms of supply is of prime importance for future market equilibrium. Despite a number of uncertainties and constraints liable to thwart the realisation of the most optimistic growth prospects, the LNG trade remains wedded to rapid growth of about 7%/year by 2020, boosting its share of world gas trade to some 38% by that horizon. (author)

  1. Australian Eager to Enter China's LNG Market

    Institute of Scientific and Technical Information of China (English)

    Li Han

    2002-01-01

    @@ Australian Trade Minister Mark Vaile made a trip to China, Japan and Republic of Korea in mid-April in an attempt to locate potential users for LNG from the northwestern continental shelf of the country.Australia has made tenacious efforts for the annual 3-million-ton LNG supply project in China's Guangdong Province. In addition, Australia also hopes to have more users in Japan and Republic of Korea.

  2. Effect of the foundation stiffness on the response of a seismically isolated tank under SSE conditions

    NARCIS (Netherlands)

    Esposito, G.; Courage, W.

    2003-01-01

    This paper presents the results of a feasibility study of a seismic isolated 120.000 m3 LNG tank. A simple model was used to evaluate the seismic response of the isolated tank under Safe Shutdown Earthquake conditions. The frequency dependent dynamic stiffness of the foundation was modele

  3. Sloshing Simulation of Three Types Tank Ship on Pitching and Heaving Motion

    Directory of Open Access Journals (Sweden)

    Edi Djatmiko

    2017-06-01

    Full Text Available As an important part of a ship, tanker / cargo hold specifically designed to distribute the load to be maintained safely. In a related IMO classification of LNG carrier, there are a wide variety of types of LNG tanks on ships. Are generally divided into two types, namely tank (Independent Self Supporting Tank and (Non Self Supporting Tanks. The tank-type variation will affect the characteristics of fluid motion that is inside the tank. Need for simulation of sloshing and analysis of the structure of the tank due to the force created by the load when the heaving and pitching. Sloshing the effect of the free movement of the fluid in the tank with the striking motion wall tank walls that can damage the walls of the tank. Type 1 tank is a tank octagonal (octogonal for membrane-type LNG carrier with dimensions of length 38 m width 39.17 m 14.5 m high side of the tank. Type 2 tank is a tank-shaped capsule with the long dimension of 26.6 m and a diameter of 10.5 m. Type 3 tank is rectangular tank (rectanguler with dimensions of length of 49.68 m, width 46.92 and 32.23 m high. Simulations conducted using Computational Fluid Dynamic (CFD using ANSYS FLUENT software. From the simulation results concluded that the tank 1 to form (octogonal have a total pressure of 3013.99 Pa on the front wall with a height of 13.65 m from the base of the tank

  4. Discussion on the height of the protective wall of the whole pressure liquefied petroleum gas storage tank%浅谈全压力式液化石油气储罐防护墙高度设计

    Institute of Scientific and Technical Information of China (English)

    乔国西

    2015-01-01

    本文分析了全压力式液化石油气储罐防护墙适宜高度的影响因素,总结了全压力式液化石油气储罐防护墙适宜高度的选取原则.%This paper analyzes the influencing factors of the suitable height of the protective wall of the full pressure liquefied petroleum gas storage tank,and summarizes the selection principle of the suitable height of the protective wall of the whole pressure liquefied petroleum gas storage tank.

  5. Application of a temperature selective heat storage tank to a solar system. Part 3. Solar heat collecting system; Ondo sentaku chikunetsuso no solar system eno tekiyo. 3. Shunetsu hoshiki ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Y. [Kanto Gakuin University, Yokohama (Japan); Kanayama, K. [Kitami Institute of Technology, Hokkaido (Japan)

    1996-10-27

    The tank system and tank-less system when the temperature selective heat storage tank is applied to a solar system were considered. In the tank system, the simulation shows that the annual supplementary heat consumption is reduced as the tank capacity becomes lower. The most suitable operating time set for determining the reference time is about five hours in winter and about nine hours in summer. The annual operating time is about 6.5 hours. In the tank-less system, the most suitable minimum flow rate per solar collector area of a heating medium in Tokyo and its districts is 10 L/hm{sup 2} for both three-step flow control and constant flow control. The tank-less system is slightly lower in annual supplementary heat consumption than the tank system. For the three-step flow control, a change in the annual supplementary heat consumption is lower than that in the minimum flow rate. For the constant flow control, however, the annual supplementary heat consumption rapidly increases when the flow rate more decreases than the optimum value. The number of pump start/stop counts for the three-step flow control is less than two times as high as for the constant flow control. 4 refs., 6 figs., 1 tab.

  6. Tank characterization reference guide

    Energy Technology Data Exchange (ETDEWEB)

    De Lorenzo, D.S.; DiCenso, A.T.; Hiller, D.B.; Johnson, K.W.; Rutherford, J.H.; Smith, D.J. [Los Alamos Technical Associates, Kennewick, WA (United States); Simpson, B.C. [Westinghouse Hanford Co., Richland, WA (United States)

    1994-09-01

    Characterization of the Hanford Site high-level waste storage tanks supports safety issue resolution; operations and maintenance requirements; and retrieval, pretreatment, vitrification, and disposal technology development. Technical, historical, and programmatic information about the waste tanks is often scattered among many sources, if it is documented at all. This Tank Characterization Reference Guide, therefore, serves as a common location for much of the generic tank information that is otherwise contained in many documents. The report is intended to be an introduction to the issues and history surrounding the generation, storage, and management of the liquid process wastes, and a presentation of the sampling, analysis, and modeling activities that support the current waste characterization. This report should provide a basis upon which those unfamiliar with the Hanford Site tank farms can start their research.

  7. 液体硝酸铵储存输送工艺与储罐的设计%Design of the Storage and Transportation Technology for Liquid Ammonium Nitrate and Storage Tank

    Institute of Scientific and Technical Information of China (English)

    杨民刚; 夏光; 粟峰雷

    2012-01-01

    通过对直接用于工业炸药生产的液体硝酸铵工艺参数的分析,提出液体硝酸铵储存输送的工艺途径,有泵送或高位差输送或两者结合等形式;论述了适合液体硝酸铵储存的储罐结构形式,储罐为薄壁容器,设计多采用立式圆筒形结构,封头多采用平盖,半椭圆形和锥形;文章还研讨了液体硝酸铵储罐和储存输送控制系统的设计方法.%Based on the analysis of the process parameters of liquid ammonium nitrate used directly in the production of industrial explosive, the store and transportation processes of liquid ammonium nitrate were advanced, such as pumping, high potential difference transportation or both. The structure of storage tank suitable for liquid ammonium nitrate was usually designed as thin walled and vertical cylindrical type, and the head was flat, semi elliptic or cone shaped. The design method of storage tank and the control system of store and transportation were also discussed.

  8. Effects of lng Mutations on LngA Expression, Processing, and CS21 Assembly in Enterotoxigenic Escherichia coli E9034A

    Science.gov (United States)

    Saldaña-Ahuactzi, Zeus; Rodea, Gerardo E.; Cruz-Córdova, Ariadnna; Rodríguez-Ramírez, Viridiana; Espinosa-Mazariego, Karina; González-Montalvo, Martín A.; Ochoa, Sara A.; González-Pedrajo, Bertha; Eslava-Campos, Carlos A.; López-Villegas, Edgar O.; Hernández-Castro, Rigoberto; Arellano-Galindo, José; Patiño-López, Genaro; Xicohtencatl-Cortes, Juan

    2016-01-01

    Enterotoxigenic Escherichia coli (ETEC) is a major cause of morbidity in children under 5 years of age in low- and middle-income countries and a leading cause of traveler's diarrhea worldwide. The ability of ETEC to colonize the intestinal epithelium is mediated by fimbrial adhesins, such as CS21 (Longus). This adhesin is a type IVb pilus involved in adherence to intestinal cells in vitro and bacterial self-aggregation. Fourteen open reading frames have been proposed to be involved in CS21 assembly, hitherto only the lngA and lngB genes, coding for the major (LngA) and minor (LngB) structural subunit, have been characterized. In this study, we investigated the role of the LngA, LngB, LngC, LngD, LngH, and LngP proteins in the assembly of CS21 in ETEC strain E9034A. The deletion of the lngA, lngB, lngC, lngD, lngH, or lngP genes, abolished CS21 assembly in ETEC strain E9034A and the adherence to HT-29 cells was reduced 90%, compared to wild-type strain. Subcellular localization prediction of CS21 proteins was similar to other well-known type IV pili homologs. We showed that LngP is the prepilin peptidase of LngA, and that ETEC strain E9034A has another peptidase capable of processing LngA, although with less efficiency. Additionally, we present immuno-electron microscopy images to show that the LngB protein could be localized at the tip of CS21. In conclusion, our results demonstrate that the LngA, LngB, LngC, LngD, LngH, and LngP proteins are essential for CS21 assembly, as well as for bacterial aggregation and adherence to HT-29 cells. PMID:27536289

  9. Sustainability of renewable fuel infrastructure: a screening LCA case study of anticorrosive graphene oxide epoxy liners in steel tanks for the storage of biodiesel and its blends.

    Science.gov (United States)

    Chilkoor, Govinda; Upadhyayula, Venkata K K; Gadhamshetty, Venkataramana; Koratkar, Nikhil; Tysklind, Mats

    2017-02-22

    Biodiesel is a widely used fuel that meets the renewable fuel standards developed under the Energy Policy Act of 2005. However, biodiesel is known to pose a series of abiotic and biotic corrosion risks to storage tanks. A typical practice (incumbent system) used to protect the tanks from these risks include (i) coating the interior surface of the tank with a solvent-free epoxy (SFE) liner, and (ii) adding a biocide to the tank. Herein, we present a screening-level life-cycle assessment study to compare the environmental performance of a graphene oxide (GO)-epoxy (GOE) liner with the incumbent system. TRACI was used as an impact assessment tool to model the midpoint environmental impacts in ten categories: global warming potential (GWP, kg CO2 eq.); acidification potential (AP, kg SO2 eq.); potential human health damage impacts due to carcinogens (HH-CP, CTUh) and non-carcinogens (HH-NCP, CTUh); potential respiratory effects (REP, kg PM2.5 eq.); eutrophication potential (EP, kg N eq.); ozone depletion potential (ODP kg CFC-11 eq.); ecotoxicity potential (ETXP, CTUe); smog formation potential (SFP kg O3 eq.) and fossil fuel depletion potential (FFDP MJ surplus). The equivalent functional unit of the LCA study was designed to protect 30 m(2) of the interior surface (unalloyed steel sheet) of a 10 000 liter biodiesel tank against abiotic and biotic corrosion during its service life of 20 years. Overall, this LCA study highlights the improved environmental performance for the GOE liner compared to the incumbent system, whereby the GOE liner showed 91% lower impacts in ODP impact category, 59% smaller in REP, 62% smaller in AP, 67-69% smaller in GWP and HH-CP, 72-76% smaller in EP, SFP, and FFDP, and 81-83% smaller ETXP and HH-NCP category results. The scenario analysis study revealed that these potential impacts change by less than 15% when the GOE liners are functionalized with silanized-GO nanosheets or GO-reinforced polyvinyl carbazole to improve the antimicrobial

  10. Fault Tree Analysis of Fire and Explosion in Oil Storage Tank%油库储油罐火灾爆炸事故树分析

    Institute of Scientific and Technical Information of China (English)

    周绍杰

    2013-01-01

    Large quantity of oil in oil storage tank is highly flammable and explosive.If any accident happens,consequences are beyond measure.According to characteristics of broad area of the security management in oil storage tank,and by analysis of the influencing factors and conditions related to fire and explosion accident in the oil storage tank,integrated fault tree model is established.The logical relationship between the accident and the basic events is clarified by carrying out qualitative analysis,while the structure importance factors of the basic events are ranked by carrying out quantitative analysis.Therefore the emphasis part in which there is potential of fire and explosion is found,and reasonable strategy for setting the security monitoring points is worked out.The results can provide basic for decision-marking of informational application in security management.%油库储油罐储存的油料具有易燃易爆性且存储量大,一旦发生事故后果严重.针对油库储油罐安全管理点多面广的特点,分析储油罐火灾爆炸事故的相关影响因素和条件,建立完善的事故树模型.通过定性分析理清火灾爆炸事故与基本事件的逻辑关系,定量分析获得顶上事件发生的概率和各基本事件的结构重要度顺序,找出储油罐存在火灾爆炸事故隐患的重点部位,制订科学合理的安全信息监控点策略,为油库安全管理手段向信息化迈进,预防事故的发生提供决策依据.

  11. Corrective Action Investigation Plan for Corrective Action Unit 127: Areas 25 and 26 Storage Tanks, Nevada Test Site, Nevada (Rev. No.: 0, August 2002)

    Energy Technology Data Exchange (ETDEWEB)

    NNSA/NV

    2002-08-27

    This Corrective Action Investigation Plan (CAIP) contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Offices's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 127 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 127 is located on the Nevada Test Site approximately 65 miles northwest of Las Vegas, Nevada. This CAU is comprised of 12 Corrective Action Sites (CASs) located at Test Cell C; the Engine Maintenance, Assembly, and Disassembly (E-MAD) Facility; the X-Tunnel in Area 25; the Pluto Disassembly Facility; the Pluto Check Station; and the Port Gaston Training Facility in Area 26. These CASs include: CAS 25-01-05, Aboveground Storage Tank (AST); CAS 25-02-02, Underground Storage Tank (UST); CAS 25-23-11, Contaminated Materials; CAS 25-12-01, Boiler; CAS 25-01-06, AST; CAS 25-01-07, AST; CAS 25-02-13, UST; CAS 26- 01-01, Filter Tank (Rad) and Piping; CAS 26-01-02, Filter Tank (Rad); CAS 26-99-01, Radioactively Contaminated Filters; CAS 26-02-01, UST; CAS 26-23-01, Contaminated Liquids Spreader. Based on site history, process knowledge, and previous field efforts, contaminants of potential concern for CAU 127 include radionuclides, metals, total petroleum hydrocarbons, volatile organic compounds, asbestos, and polychlorinated biphenyls. Additionally, beryllium may be present at some locations. The sources of potential releases are varied, but releases of contaminated liquids may have occurred and may have migrated into and impacted soil below and surrounding storage vessels at some of the CASs. Also, at several CASs, asbestos-containing materials may be present on the aboveground structures and may be friable. Exposure pathways are limited to ingestion, inhalation, and dermal contact (adsorption) of soils/sediments or liquids, or inhalation of contaminants by site workers due to disturbance of

  12. Corrective Action Investigation Plan for Corrective Action Unit 127: Areas 25 and 26 Storage Tanks, Nevada Test Site, Nevada (Rev. No.: 0, August 2002)

    Energy Technology Data Exchange (ETDEWEB)

    NNSA/NV

    2002-08-27

    This Corrective Action Investigation Plan (CAIP) contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Offices's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 127 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 127 is located on the Nevada Test Site approximately 65 miles northwest of Las Vegas, Nevada. This CAU is comprised of 12 Corrective Action Sites (CASs) located at Test Cell C; the Engine Maintenance, Assembly, and Disassembly (E-MAD) Facility; the X-Tunnel in Area 25; the Pluto Disassembly Facility; the Pluto Check Station; and the Port Gaston Training Facility in Area 26. These CASs include: CAS 25-01-05, Aboveground Storage Tank (AST); CAS 25-02-02, Underground Storage Tank (UST); CAS 25-23-11, Contaminated Materials; CAS 25-12-01, Boiler; CAS 25-01-06, AST; CAS 25-01-07, AST; CAS 25-02-13, UST; CAS 26- 01-01, Filter Tank (Rad) and Piping; CAS 26-01-02, Filter Tank (Rad); CAS 26-99-01, Radioactively Contaminated Filters; CAS 26-02-01, UST; CAS 26-23-01, Contaminated Liquids Spreader. Based on site history, process knowledge, and previous field efforts, contaminants of potential concern for CAU 127 include radionuclides, metals, total petroleum hydrocarbons, volatile organic compounds, asbestos, and polychlorinated biphenyls. Additionally, beryllium may be present at some locations. The sources of potential releases are varied, but releases of contaminated liquids may have occurred and may have migrated into and impacted soil below and surrounding storage vessels at some of the CASs. Also, at several CASs, asbestos-containing materials may be present on the aboveground structures and may be friable. Exposure pathways are limited to ingestion, inhalation, and dermal contact (adsorption) of soils/sediments or liquids, or inhalation of contaminants by site workers due to disturbance of

  13. Opposed Bellows Would Expel Contents Of Tank

    Science.gov (United States)

    Whitaker, Willie

    1994-01-01

    Proposed storage tank contains two pairs of opposed bellows used to expel its contents. Storage and expulsion volumes of tank same as those of older version of tank equipped with single bellows. Four bellows offer greater stability. Applications include automobile cooling systems and gasoline-powered tools like chain saws and leaf blowers.

  14. 75 FR 11000 - Security Zone; Freeport LNG Basin, Freeport, TX

    Science.gov (United States)

    2010-03-10

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA87 Security Zone; Freeport LNG Basin, Freeport, TX AGENCY... in the Freeport LNG Basin. This security zone is needed to protect vessels, waterfront facilities... notice of proposed rulemaking (NPRM) entitled Security Zone; Freeport LNG Basin, Freeport, TX in...

  15. 49 CFR 193.2019 - Mobile and temporary LNG facilities.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Mobile and temporary LNG facilities. 193.2019... LIQUEFIED NATURAL GAS FACILITIES: FEDERAL SAFETY STANDARDS General § 193.2019 Mobile and temporary LNG facilities. (a) Mobile and temporary LNG facilities for peakshaving application, for service...

  16. 75 FR 26744 - Cameron LNG, LLC; Notice of Application

    Science.gov (United States)

    2010-05-12

    ...-000] Cameron LNG, LLC; Notice of Application May 5, 2010. On April 22, 2010, Cameron LNG, LLC filed... liquefied natural gas terminal in Cameron Parish, Louisiana. Questions concerning this application may be directed to William D. Rapp, Senior Regulatory Counsel at Cameron LNG, LLC, 101 Ash Street, HQ-12, San...

  17. 76 FR 73609 - Cameron LNG, LLC; Notice of Application

    Science.gov (United States)

    2011-11-29

    ... Energy Regulatory Commission Cameron LNG, LLC; Notice of Application Take notice that on November 4, 2010, Cameron LNG, LLC (Cameron), 101 Ash Street, San Diego, California 92101, filed in Docket No. CP12- 15-000... operate a boil-off gas (BOG) liquefaction system at its LNG import terminal in Cameron Parish, Louisiana...

  18. Nevada test site underground storage tank number 12-13-1: Nevada division of emergency management case number H931130E corrective action unit 450. Closure report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-01-01

    The project site was identified as an abandoned Underground Storage Tank (UST) to be closed under the Department of Energy/Nevada Operations Office (DOE/NV) Environmental Restoration Division (ERD) Program during Fiscal Year 1993. The United States Environmental Protection Agency (EPA) requires that before permanent closure is completed an assessment of the site must take place. The Nevada Division of Environmental Protection (NDEP) requires assessment and corrective actions for a petroleum substance in the soil which exceeds 100 milligrams per kilogram (mg/kg). Subsequent to the tank removal, a hydrocarbon release was identified at the site. The release was reported to the NDEP by DOE/NV on November 30, 1993. Nevada Division of Environmental Management (NDEM) Case Number H931130E was assigned. This final closure report documents the assessment and corrective actions taken for the hydrocarbon release identified at the site. The Notification of Closure, EPA Form 7530-1 dated March 22, 1994, is provided in Appendix A. A 45-day report documenting the notification for a hydrocarbon release was submitted to NDEP on April 6, 1994.

  19. Feasibility study for measurement of insulation compaction in the cryogenic rocket fuel storage tanks at Kennedy Space Center by fast/thermal neutron techniques

    Science.gov (United States)

    Livingston, R. A.; Schweitzer, J. S.; Parsons, A. M.; Arens, E. E.

    2014-02-01

    The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Some of the perlite may have compacted over time, compromising the thermal performance and also the structural integrity of the tanks. Neutrons can readily penetrate through the 1.75 cm outer steel shell and through the entire 120 cm thick perlite zone. Neutrons interactions with materials produce characteristic gamma rays which are then detected. In compacted perlite the count rates in the individual peaks in the gamma ray spectrum will increase. Portable neutron generators can produce neutron simultaneous fluxes in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scattering which is sensitive to Si, Al, Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA), which is sensitive to Si, Al, Na, K and H among others. The results of computer simulations using the software MCNP and measurements on a test article suggest that the most promising approach would be to operate the system in time-of-flight mode by pulsing the neutron generator and observing the subsequent die away curve in the PGNA signal.

  20. Feasibility study for measurement of insulation compaction in the cryogenic rocket fuel storage tanks at Kennedy Space Center by fast/thermal neutron techniques

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, R. A. [Materials Science and Engineering Dept., U. of Maryland, College Park, MD (United States); Schweitzer, J. S. [Physics Dept., U. of Connecticut, Storrs (United States); Parsons, A. M. [Goddard Space Flight Center, Greenbelt (United States); Arens, E. E. [John F. Kennedy Space Center, FL (United States)

    2014-02-18

    The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Some of the perlite may have compacted over time, compromising the thermal performance and also the structural integrity of the tanks. Neutrons can readily penetrate through the 1.75 cm outer steel shell and through the entire 120 cm thick perlite zone. Neutrons interactions with materials produce characteristic gamma rays which are then detected. In compacted perlite the count rates in the individual peaks in the gamma ray spectrum will increase. Portable neutron generators can produce neutron simultaneous fluxes in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scattering which is sensitive to Si, Al, Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA), which is sensitive to Si, Al, Na, K and H among others. The results of computer simulations using the software MCNP and measurements on a test article suggest that the most promising approach would be to operate the system in time-of-flight mode by pulsing the neutron generator and observing the subsequent die away curve in the PGNA signal.

  1. Fire Control System Design of Flammable Liquid Vertical Storage Tank Farm%可燃液体立式储罐罐区消防系统设计

    Institute of Scientific and Technical Information of China (English)

    时晓宁; 王全贵

    2016-01-01

    The paper introduces classification and structure of the fire-control cooling water system and foam fire-fighting system about the flammable liquid vertical storage tank farm, and combines some tank farm project engineering design example to expound the calculation process and the equipment selection of the fixed fire-control cooling water system as wel as the calculation process and equipment selection of fixed foam fire-fighting system.%介绍了甲、乙、丙类可燃液体立式储罐罐区消防冷却水系统和泡沫灭火系统的分类和组成,并结合某项目罐区工程设计实例阐述了固定式消防冷却水系统计算过程、设备选型以及固定式泡沫灭火系统计算过程和设备选型。

  2. Streamlined approach for environmental restoration closure report for Corrective Action Unit 120: Areas 5 and 6 aboveground storage tanks, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-06-01

    This Closure Report provides documentation for the closure of Corrective Action Unit (CAU) 120 of the Federal Facilities Agreement and Consent Order (FFACO). CAU 120 consists of two Corrective Action Sites (CASs) located in Areas 5 and 6 of the Nevada Test Site (NTS), which are approximately 130 kilometers (80 miles) northwest of Las Vegas, Nevada. CAS 05-01-01 is located in Area 5 and consists of three 45,800-liter (12,100-gallon) aboveground storage tanks (ASTs), piping, and debris associated with Well RNM-1. CAS 06-01-01 consists of two ASTs and two tanker trailers (all portable) that were originally located at the Area 6 Cp-50 Hot Park and which had been moved to the Area 6 Waste Handling Facility. All of the items in CAU 120 have been used to contain or convey radiologically contaminated fluid that was generated during post-nuclear event activities at the NTS.

  3. Application of Mechanical Cleaning Method of Crude Oil Storage Tank%机械方法清理原油储罐的应用

    Institute of Scientific and Technical Information of China (English)

    吴笛; 李文辉; 马小兵

    2014-01-01

    通过对人工及机械方法清理原油储罐的特点进行对比分析,提出了机械清理方法的原理及方法。通过试验研究发现,机械清理方法在安全性、环境保护、节约能源及成本控制等方面具有突出的优势。%By way of artificial and mechanical characteristics of crude oil storage tank cleaning comparative analysis of mechanical cleaning methods proposed principles and methods,the study found that mechanical cleaning methods,in safety,environmental protection,energy conserva-tion,cost control,has outstanding advantages.

  4. Streamlined approach for environmental restoration closure report for Corrective Action Unit 464: Historical underground storage tank release sites, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    This report addresses the site characterization of two historical underground storage tank petroleum hydrocarbon release sites identified by Corrective Action Site (CAS) Numbers 02-02-03 and 09-02-01. The sites are located at the Nevada Test Site in Areas 2 and 9 and are concrete bunker complexes (Bunker 2-300, and 9-300). Characterization was completed using drilling equipment to delineate the extent of petroleum hydrocarbons at release site 2-300-1 (CAS 02-02-03). Based on site observations, the low hydrocarbon concentrations detected, and the delineation of the vertical and lateral extent of subsurface hydrocarbons, an ``A through K`` evaluation was completed to support a request for an Administrative Closure of the site.

  5. 大型油品储罐进出口管线柔性设计%Flexible Design in the Inlet and Outlet Pipeline of Large Storage Tank

    Institute of Scientific and Technical Information of China (English)

    宋义伟; 郭慧军; 张永东; 田鹤; 杨振东; 安宗旺

    2011-01-01

    The necessity of flexible design in the inlet and outlet pipeline of large storage tank was analyzed. The structure, function and selection of equipment of metal hose and corrugatedpipe compensator were presented. The matters that needed attention about installation of metal hose and corrugated-pipe compensator were also introduced simply.%分析了大型储罐进出口管线柔性设计的必要性,介绍了金属软管和波纹补偿器的结构形式、作用及设备选型需考虑的因素,提出了在进行储罐罐前柔性安装时应注意的问题.

  6. Analysis of nodalization effects on the prediction error of generalized finite element method used for dynamic modeling of hot water storage tank

    Directory of Open Access Journals (Sweden)

    Wołowicz Marcin

    2015-09-01

    Full Text Available The paper presents dynamic model of hot water storage tank. The literature review has been made. Analysis of effects of nodalization on the prediction error of generalized finite element method (GFEM is provided. The model takes into account eleven various parameters, such as: flue gases volumetric flow rate to the spiral, inlet water temperature, outlet water flow rate, etc. Boiler is also described by sizing parameters, nozzle parameters and heat loss including ambient temperature. The model has been validated on existing data. Adequate laboratory experiments were provided. The comparison between 1-, 5-, 10- and 50-zone boiler is presented. Comparison between experiment and simulations for different zone numbers of the boiler model is presented on the plots. The reason of differences between experiment and simulation is explained.

  7. TANK SPACE OPTIONS REPORT

    Energy Technology Data Exchange (ETDEWEB)

    WILLIS WL; AHRENDT MR

    2009-08-11

    Since this report was originally issued in 2001, several options proposed for increasing double-shell tank (DST) storage space were implemented or are in the process of implementation. Changes to the single-shell tank (SST) waste retrieval schedule, completion of DST space saving options, and the DST space saving options in progress have delayed the projected shortfall of DST storage space from the 2007-2011 to the 2018-2025 timeframe (ORP-11242, River Protection Project System Plan). This report reevaluates options from Rev. 0 and includes evaluations of new options for alleviating projected restrictions on SST waste retrieval beginning in 2018 because of the lack of DST storage space.

  8. An Approach for Developing Site-Specific Lateral and Vertical Inclusion Zones within which Structures Should be Evaluated for Petroleum Vapor Intrusion due to Releases of Motor Fuel from Underground Storage Tanks

    Science.gov (United States)

    Buildings may be at risk from Petroleum Vapor Intrusion (PVI) when they overlie petroleum hydrocarbon contamination in the unsaturated zone or dissolved in groundwater. The U.S. EPA Office of Underground Storage Tanks (OUST) is preparing Guidance for Addressing Petroleum Vapor I...

  9. World`s largest underground oil storage tank in Akita; Akita ni 450 man kl sekiyu bichiku kichi kansei majika (sekai saidai yoryo no chichushiki gen`yu tanku kichi kensetsu)

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, K. [The Univ., of Tokyo, Tokyo (Japan). Faculty of Engineering

    1995-01-15

    The Akita Oil Storage Base is consisted of the onshore facilities such as the western base (39 ha; storage capacity 1.66 million kl) filled by earth in 1979, and the eastern base (71 ha; storage capacity 2.82 million kl) filled by earth in this project, as well as, the shipping/receiving facility of 180,000DWT class berth constructed in the offshore about 1 km to south and so forth. Out of them, the oil in was executed in the western base in November 1989, and in the 1st phase of the eastern base in December 1992 respectively, and they are already in operation. In addition currently, the underground tank of the 2nd phase construction work in the eastern base is nearly in completion, an appurtenant work are being advanced towards the oil in scheduled in July 1995. The underground tank in this base is the 1st structure in Japan as the tank installed insides the rockmass. In this project, by performing the effective utilization of the great quantity of an excavated rock, as well as, the organically systematized informatics execution of a design, execution and measurement, total work were advanced safer and more economically, and as a consequence the oil storage base with the underground tank of the maximum capacity in the world is in close to completion. 7 figs.

  10. 化工企业可燃液体储罐区的通用安全要求%The General Safety Requirements of Chemical Companies Flammable Liquid Storage Tank Area

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    The article mainly introduce the selection,layout and security monitoring equipment of chemical companies flammable liquid storage tank.%  介绍在化工装置可燃液体罐区储罐的选型、布置和安全监控装备的设置。

  11. 储罐区火灾引发多米诺效应的概率分析方法%Probability Analysis for Domino Effect Triggered by Storage Tank Fire

    Institute of Scientific and Technical Information of China (English)

    周剑峰

    2015-01-01

    石化工业储罐区储存大量易燃物质,储罐发生火灾可能对邻近储罐造成影响,引发严重的多米诺事故。火灾发生后的应急响应会对事故发展造成影响,并影响多米诺效应的发生概率。结合Probit分析方法和我国火灾应急响应统计数据,建立了储罐区火灾引发多米诺效应的概率分析模型,并以汽油储罐火灾为例,分析了多米诺效应的概率。%In petrochemical industry ,large quantities of different flammable substances are stored in tank areas .Due to mutual impacts among the tanks ,severe domino accidents may occur after a tank catches fire .The emergency response to a tank fire may influence the development of the accident and impact on the occurring likelihood of domino effects .Based on the Probit method for assessing domino effect triggered by fire and the statistical emergency response data of our country ,the probability assessment model for domino effect triggered by tank fire is proposed .Tank fire among gasoline storage tanks is taken as an example to illustrate this approach .

  12. Modeling of LNG spills into trenches.

    Science.gov (United States)

    Gavelli, Filippo; Chernovsky, Melissa K; Bullister, Edward; Kytomaa, Harri K

    2010-08-15

    A new method for the analysis of LNG spills into trenches has been developed to quantify vapor dispersion hazard distances. The model uses three steps to capture the behavior of an LNG spill into a trench. The first is to analytically calculate the evolving LNG flow, the second to calculate the vaporization rate along the trench, and the third is to calculate the dispersion of the vapors using a CFD model that has been validated for this application in the presence of complex geometries. This paper presents case studies that show the effect of wind perpendicular and parallel to the large aspect ratio trenches on vapor dispersion. The case studies also demonstrate the effect of complex terrain and obstacles such as vapor fences on vapor dispersion. The simulations show that wind direction relative to the trench has a significant effect on cloud shape, height, and maximum downwind distance. The addition of vapor fences to mitigate vapor dispersion hazards from an LNG spill into the LNG containment trench is shown to be effective.

  13. Tank System Integrated Model: A Cryogenic Tank Performance Prediction Program

    Science.gov (United States)

    Bolshinskiy, L. G.; Hedayat, A.; Hastings, L. J.; Sutherlin, S. G.; Schnell, A. R.; Moder, J. P.

    2017-01-01

    Accurate predictions of the thermodynamic state of the cryogenic propellants, pressurization rate, and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning for future space exploration missions. This Technical Memorandum (TM) presents the analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, mixing, and condensation on the tank wall. This TM also includes comparisons of TankSIM program predictions with the test data andexamples of multiphase mission calculations.

  14. High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The purpose of this Requirements Identification Document (RID) section is to identify, in one location, all of the facility specific requirements and good industry practices which are necessary or important to establish an effective Issues Management Program for the Tank Farm Facility. The Management Systems Functional Area includes the site management commitment to environmental safety and health (ES&H) policies and controls, to compliance management, to development and management of policy and procedures, to occurrence reporting and corrective actions, resource and issue management, and to the self-assessment process.

  15. Mathematical Simulation of Convective Heat Transfer in the Low-Temperature Storage of Liquefied Natural Gas

    Directory of Open Access Journals (Sweden)

    Shestakov Igor A.

    2015-01-01

    Full Text Available The article shows the results of mathematical modeling of convective heat transfer in the low-temperature storage of liquefied natural gas. Regime of natural convection in an enclosure with different intensity of the heat flux at the external borders are investigated. Was examined two-dimensional nonstationary problem within the model of Navier-Stokes in dimensionless variables “vorticity - stream function - temperature”. Distributions of hydrodynamic parameters and temperatures that characterize the basic regularities of the processes are obtained. Circulating flows are determined and carried out the analysis of vortices formation mechanism and the temperature distribution in solution at conditions of natural convection when the Grashof number (Gr = 106. A significant influence of heat transfer rate on solutions boundary on flow structure and temperature field in LNG storage tanks.

  16. The globalization and environmental sustainability of LNG: Is LNG a fuel for the 21st century?

    Energy Technology Data Exchange (ETDEWEB)

    Sakmar, Susan

    2010-09-15

    As the world enters the 21st Century, policy makers around the world are grappling with issues related to energy security, energy poverty, global climate change, and the need to reduce greenhouse gas emissions while meeting an expected increase in demand for all energy sources. As a clean burning fuel, many policy leaders have suggested that LNG can play an important role as the world struggles to develop a more environmental sustainable energy future. Others claim that the safety and environmental impact of LNG, including life-cycle emissions, may nullify any clean burning benefit LNG might otherwise provide.

  17. Injector for CESAR (2 MeV electron storage ring): 2-beam, 2 MV van de Graaff generator; tank removed.

    CERN Multimedia

    1968-01-01

    The van de Graaff generator in its tank. For voltage-holding, the tank was filled with pressurized extra-dry nitrogen. 2 beams emanated from 2 separate electron-guns. The left beam, for injection into the CESAR ring, was pulsed at 50 Hz, with currents of up to 1 A for 400 ns. The right beam was sent to a spectrometer line. Its pulselength was also 400 ns, but the pulse current was 12 microA, at a rate variable from 50 kHz to 1 MHz. This allowed stabilization of the top-terminal voltage to an unprecedented stability of +- 100 V, i.e. 6E-5. Although built for a nominal voltage of 2 MV, the operational voltage was limited to 1.75 MV in order to minimize voltage break-down events. CESAR was terminated at the end of 1967 and dismantled in 1968. R.Nettleton (left) and H.Burridge (right) are preparing the van de Graaff for shipment to the University of Swansea.

  18. High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The Quality Assurance Functional Area Requirements Identification Document (RID), addresses the programmatic requirements that ensure risks and environmental impacts are minimized, ensure safety, reliability, and performance are maximized through the application of effective management systems commensurate with the risks posed by the Tank Farm Facility and its operation. This RID incorporates guidance intended to provide Tank Farms management with the necessary requirements information to develop, upgrade, or assess the effectiveness of a Quality Assurance Program in the performance of organizational and functional activities. Quality Assurance is defined as all those planned and systematic actions necessary to provide adequate confidence that a facility, structure, system, or component will perform satisfactorily and safely in service. This document will provide the specific requirements to meet DNFSB recommendations and the guidance provided in DOE Order 5700.6C, utilizing industry codes, standards, regulatory guidelines, and industry good practices that have proven to be essential elements for an effective and efficient Quality Assurance Program as the nuclear industry has matured over the last thirty years.

  19. 水平和竖向地震激励下大型储液罐响应分析%The Response Analysis of Liquid Storage Tank under Horizontal and Vertical Seismic Excitation

    Institute of Scientific and Technical Information of China (English)

    陈贵清; 刘望峰; 赵晓波; 梁乐杰

    2012-01-01

    基于ANSYS软件建立了100km3锚固型大型储液罐模型,并对此进行了水平和竖向地震激励下的地震响应分析,地震波为EL-CENTRO波。计算结果表明,锚固型大型储液罐内液体的晃动、应力和应变在水平地震激励下比竖向地震激励下大很多,这说明水平地震激励是影响储液罐力学性状的主要因素之一。储液罐的应力和应变峰值发生在罐的中下部,而罐口变形较大。%The finite element model of the 1×105 m3 anchored liquid-storage tank was set up based on ANASYS.The response of the tank in horizontal and vertical seismic excitation were analyzed,and the exciting seismic wave was EL-CENTRO wave.The results show that the sloshing of the liquid in the liquid-storage under horizontal seismic excitation is more wildly than that under vertical seismic excitation,and also the stress and strain under horizontal seismic excitation are greater than that under vertical seismic excitation.The result shows that the horizontal seismic excitation is one main factor that affects the mechanical properties of the liquid storage tank when earthquake happened.The peak values of the stress and the strain occurs at the middle or lower parts of the liquid storage tank,and deformation at port of the liquid storage tank is bigger than anywhere else.

  20. The Influence of Chemical Composition on LNG Pool Vaporization

    Directory of Open Access Journals (Sweden)

    Yu Zhidong

    2017-01-01

    Full Text Available A model is used to examine the influence of chemical composition on the vaporization rate of LNG during spreading. Calculations have been performed whereby the vaporization rate of the LNG mixtures has been compared to the vaporization of pure methane under the initial conditions. The detailed results indicate that the vaporization rate LNG mixture is different to that of pure methane. LNG as the liquid mixture gets rich in ethane and isobaric latent heat increases rapidly, leading to the rate vaporization of LNG decrease in compared to pure methane.