WorldWideScience

Sample records for living room floor

  1. Thermal storage in a heat pump heated living room floor for urban district power balancing - effects on thermal comfort, energy loss and costs for residents

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; de Wit, J.B.; Fink, J.; Smit, Gerardus Johannes Maria

    2014-01-01

    For the Dutch smart grid demonstration project Meppelenergie, the effects of controlled thermal energy storage within the floor heating structure of a living room by a heat pump are investigated. Storage possibilities are constrained by room operative and floor temperatures. Simulations indicate

  2. Crack resistance increasing in epoxide-rubber coatings of NPP room floors

    International Nuclear Information System (INIS)

    Khorenzhenko, V.I.

    1986-01-01

    Problems of crack resistance increasing in epoxide-rubber coatings for the floors are considered. Exploitation experience of the floors in the special rooms of NPP is given. Perspectivity of application of the compositions described as the building materials for nuclear power stations is pointed out

  3. Airflow and Heat Transfer in the Slot-Vented Room with Radiant Floor Heating Unit

    Directory of Open Access Journals (Sweden)

    Xiang-Long Liu

    2012-01-01

    Full Text Available Radiant floor heating has received increasing attention due to its diverse advantages, especially the energy saving as compared to the conventional dwelling heating system. This paper presents a numerical investigation of airflow and heat transfer in the slot-vented room with the radiant floor heating unit. Combination of fluid convection and thermal radiation has been implemented through the thermal boundary conditions. Spatial distributions of indoor air temperature and velocity, as well as the heat transfer rates along the radiant floor and the outer wall, have been presented and analyzed covering the domains from complete natural convection to forced convection dominated flows. The numerical results demonstrate that the levels of average temperature in the room with lateral slot-ventilation are higher than those without slot-ventilation, but lower than those in the room with ceiling slot-ventilation. Overall, the slot-ventilation room with radiant floor heating unit could offer better indoor air quality through increasing the indoor air temperature and fresh air exchanging rate simultaneously. Concerning the airborne pollutant transports and moisture condensations, the performance of radiant floor heating unit will be further optimized in our future researches.

  4. Our Urban Living Room

    DEFF Research Database (Denmark)

    Hjortshøj, Rasmus

    2016-01-01

    Our Urban Living Room is an exhibition and a book, created by Cobe. The theme is based on Cobe’s ten years of practice, grounded in social livability and urban democracy, and our aim to create buildings and spaces that invite Copenhageners to use and define them; as an extended living room, where...... the boundaries between private and public space become fluid. Based on specific Cobe projects, Our Urban Living Room tells stories about the architectural development of Copenhagen, while exploring the progression of the Danish Capital - from an industrial city into an urban living room, known as one...... of the world’s most livable places. Photography by Rasmus Hjortshøj....

  5. On buoyancy-driven natural ventilation of a room with a heated floor

    Science.gov (United States)

    Gladstone, Charlotte; Woods, Andrew W.

    2001-08-01

    The natural ventilation of a room, both with a heated floor and connected to a cold exterior through two openings, is investigated by combining quantitative models with analogue laboratory experiments. The heated floor generates an areal source of buoyancy while the openings allow displacement ventilation to operate. When combined, these produce a steady state in which the air in the room is well-mixed, and the heat provided by the floor equals the heat lost by displacement. We develop a quantitative model describing this process, in which the advective heat transfer through the openings is balanced with the heat flux supplied at the floor. This model is successfully tested with observations from small-scale analogue laboratory experiments. We compare our results with the steady-state flow associated with a point source of buoyancy: for a given applied heat flux, an areal source produces heated air of lower temperature but a greater volume flux of air circulates through the room. We generalize the model to account for the effects of (i) a cooled roof as well as a heated floor, and (ii) an external wind or temperature gradient. In the former case, the direction of the flow through the openings depends on the temperature of the exterior air relative to an averaged roof and floor temperature. In the latter case, the flow is either buoyancy dominated or wind dominated depending on the strength of the pressure associated with the wind. Furthermore, there is an intermediate multiple-solution regime in which either flow regime may develop.

  6. Floor cleaning: effect on bacteria and organic materials in hospital rooms.

    Science.gov (United States)

    Andersen, B M; Rasch, M; Kvist, J; Tollefsen, T; Lukkassen, R; Sandvik, L; Welo, A

    2009-01-01

    Routine surface cleaning is recommended to control the spread of pathogens in hospital environments. In Norway, ordinary cleaning of patient rooms is traditionally performed with soap and water. In this study, four floor-mopping methods--dry, spray, moist and wet mopping--were compared by two systems using adenosine triphosphate (ATP) bioluminescence (Hygiena and Biotrace). These systems assess residual organic soil on surfaces. The floor-mopping methods were also assessed by microbiological samples from the floor and air, before and after cleaning. All methods reduced organic material on the floors but wet and moist mopping seemed to be the most effective (P < 0.001, P < 0.011, respectively, ATP Hygiena). The two ATP methods were easy to use, although each had their own reading scales. Cleaning reduced organic material to 5-36% of the level present before cleaning, depending upon mopping method. All four mopping methods reduced bacteria on the floor from about 60-100 to 30-60 colony-forming units (cfu)/20cm2 floor. Wet, moist and dry mopping seemed to be more effective in reducing bacteria on the floor, than the spray mopping (P=0.007, P=0.002 and P=0.011, respectively). The burden of bacteria in air increased for all methods just after mopping. The overall best cleaning methods seemed to be moist and wet mopping.

  7. Efficacy of manual cleaning and an ultraviolet C room decontamination device in reducing health care-associated pathogens on hospital floors.

    Science.gov (United States)

    Mustapha, Aishat; Alhmidi, Heba; Cadnum, Jennifer L; Jencson, Annette L; Donskey, Curtis J

    2018-05-01

    Recent studies suggest that floors may be an underappreciated source for transmission of health care-associated pathogens. However, there are limited data on the effectiveness of current cleaning and disinfection methods in reducing floor contamination. We demonstrated that manual postdischarge cleaning by environmental services personnel significantly reduced floor contamination, and an automated ultraviolet C room disinfection device was effective as an adjunct to manual cleaning. Published by Elsevier Inc.

  8. The Sea Floor: A Living Learning Residential Community

    Science.gov (United States)

    Guentzel, J. L.; Rosch, E.; Stoughton, M. A.; Bowyer, R.; Mortensen, K.; Smith, M.

    2016-02-01

    Living learning communities are collaborations between university housing and academic departments designed to enhance the overall student experience by integrating classroom/laboratory learning, student life and extracurricular activities. At Coastal Carolina University, the residential community associated with the Marine Science program is known as the Sea Floor. Students selected to become members of the Sea Floor remain "in residence" for two consecutive semesters. These students are first-time freshman that share a common course connection. This course is usually Introduction to Marine Science (MSCI 111) or MSCI 399s, which are one credit field/laboratory centered internships. The common course connection is designed so residents can establish and maintain an educational dialog with their peers. Activities designed to enhance the students' networking skills and educational and social development skills include monthly lunches with marine science faculty and dinner seminars with guest speakers from academia, industry and government. Additionally, each semester several activities outside the classroom are planned so that students can more frequently interact with themselves and their faculty and staff partners. These activities include field trips to regional aquariums, local boat trips that include water sample collection and analysis, and an alternative spring break trip to the Florida Keys to study the marine environment firsthand. The resident advisor that supervises the Sea Floor is usually a sophomore or junior marine science major. This provides the residents with daily communication and mentoring from a marine science major that is familiar with the marine science program and residence life. Assessment activities include: a university housing community living survey, student interest housing focus groups, fall to spring and fall to fall retention, and evaluation of program advisors and program activities.

  9. Floor Covering and Surface Identification for Assistive Mobile Robotic Real-Time Room Localization Application

    Directory of Open Access Journals (Sweden)

    Michael Gillham

    2013-12-01

    Full Text Available Assistive robotic applications require systems capable of interaction in the human world, a workspace which is highly dynamic and not always predictable. Mobile assistive devices face the additional and complex problem of when and if intervention should occur; therefore before any trajectory assistance is given, the robotic device must know where it is in real-time, without unnecessary disruption or delay to the user requirements. In this paper, we demonstrate a novel robust method for determining room identification from floor features in a real-time computational frame for autonomous and assistive robotics in the human environment. We utilize two inexpensive sensors: an optical mouse sensor for straightforward and rapid, texture or pattern sampling, and a four color photodiode light sensor for fast color determination. We show how data relating floor texture and color obtained from typical dynamic human environments, using these two sensors, compares favorably with data obtained from a standard webcam. We show that suitable data can be extracted from these two sensors at a rate 16 times faster than a standard webcam, and that these data are in a form which can be rapidly processed using readily available classification techniques, suitable for real-time system application. We achieved a 95% correct classification accuracy identifying 133 rooms’ flooring from 35 classes, suitable for fast coarse global room localization application, boundary crossing detection, and additionally some degree of surface type identification.

  10. A nodal model to predict vertical temperature distribution in a room with floor heating and displacement ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Olesen, Bjarne W.; Fang, Lei

    2013-01-01

    In this paper, the development of a nodal model that predicts vertical temperature distribution in a typical office room with floor heating and displacement ventilation (FHDV) is described. The vertical air flow distribution is first determined according to the principle of displacement ventilati...

  11. Concentration of Radon, thoron and their progeny levels in different types of floorings, walls, rooms and building materials

    International Nuclear Information System (INIS)

    Sathish, L. A.; Nagaraja, K.; Ramanna, H. C.; Nagesh, V.; Sundareshan, S.

    2009-01-01

    Radon, thoron and their progenies are the most important contributions to human exposure from natural sources. Radon exists in soil gas, building materials, Indoor atmosphere etc. Among all the natural sources of radiation dose to human beings, inhalation of radon contributes a lot. The work presented here emphasizes the long term measurements of radon, thoron and their progeny concentrations in about 100 dwellings using solid state nuclear track detectors. Materials and Methods: Measurements were made using dosimeters and the concentrations were estimated by knowing the track density of films through spark counter, and sensitivity factor for bare, filter and membrane films. Results: Presence of radon and thoron in houses is the effect of several aspects such as the activity concentrations of uranium, radium and thorium in the local soil, building materials, ventilation of houses and also entry of radon into houses through the cracks in floor/wall. Conclusion: The observations reveal that the concentrations of radon and/or thoron are relatively higher in granite than in concrete, cement and bricks. In continuation to this the concentration observed in bathrooms is more compared to kitchen bedroom and living rooms. This study discloses that the residential rooms of good ventilation will avoid the health hazards due to radon and its rich materials.

  12. On The Living Room

    Directory of Open Access Journals (Sweden)

    Thomas Richards

    2013-03-01

    Full Text Available This text discusses the work The Living Room, directed by the author, and reflects on its meanings and functions. The article confronts problems performance raises in relation to contemporary social life, bringing forward the isolation of life today and the possibilities performance offers to fight it. We problematise the crisis experienced by the author and the consequent creation of the work as a mobile performative device in relation to the staging space. Finally, the work questions the forms of interaction and type of participation possible in performance.

  13. Influence of staircase ventilation state on the airflow and heat transfer of the heated room on the middle floor of high rise building

    International Nuclear Information System (INIS)

    Shi, W.X.; Ji, J.; Sun, J.H.; Lo, S.M.; Li, L.J.; Yuan, X.Y.

    2014-01-01

    Highlights: • Experiments are conducted in a scaled building model. • The flow and heat transfer in the heated room are investigated. • The staircase ventilation state influence on the heated room. • The results are useful to understand the safety and energy efficiency of building. - Abstract: Safety and energy efficiency of high rise buildings have attracted public attention in recent decades. In this paper, a set of experiments was conducted in a scaled building model with 12 floors to study the influence of the staircase ventilation state on the flow and heat transfer of the heated room on the middle floor. The airflow, room temperature and fuel burning rate were investigated. It is found that when the window above the heated room is opened, the vents state below the heated room has a significant effect on the airflow and heat transfer in the heated room. When the vents below the heated room are closed, the single-directional air flows into the heated room owing to the stronger stack effect. And the flame tilt angle is larger and the upper hot smoke temperature in the heated room is low. However, when the windows above the heated room are closed, the vents state below the heated room has little influence on the airflow and heat transfer in the heated room. And, there is two-directional air flowing through the door of the heated room The burning rate of heat source is also affected by the staircase ventilation state, and the variation trend varies with the opened window position and pool size

  14. Flow patterns and thermal comfort in a room with panel, floor and wall heating

    Energy Technology Data Exchange (ETDEWEB)

    Myhren, Jonn Are; Holmberg, Sture [Fluid and Climate Technology, Department of Constructional Engineering and Design, KTH, School of Technology and Health, Marinens vaeg 30, SE-13640 Haninge-Stockholm (Sweden)

    2008-07-01

    Thermal comfort aspects in a room vary with different space heating methods. The main focus in this study was how different heating systems and their position affect the indoor climate in an exhaust-ventilated office under Swedish winter conditions. The heat emitters used were a high and a medium-high temperature radiator, a floor heating system and large wall heating surfaces at low temperature. Computational fluid dynamics (CFD) simulations were used to investigate possible cold draught problems, differences in vertical temperature gradients, air speed levels and energy consumption. Two office rooms with different ventilation systems and heating needs were evaluated. Both systems had high air exchange rates and cold infiltration air. The general conclusions from this study were that low temperature heating systems may improve indoor climate, giving lower air speeds and lower temperature differences in the room than a conventional high temperature radiator system. The disadvantage with low temperature systems is a weakness in counteracting cold down-flow from ventilation supply units. For that reason the location of heat emitters and the design of ventilation systems proved to be of particular importance. Measurements performed in a test chamber were used to validate the results from the CFD simulations. (author)

  15. Numerical Investigation of Floor Heating Systems in Low Energy Houses

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Kragh, Jesper; Jensen, Claus Franceos

    2002-01-01

    In this paper an investigation of floor heating systems is performed with respect to heating demand and room temperature. Presently (2001) no commercially available building simulation programs that can be used to evaluate heating demand and thermal comfort in buildings with building integrated....... The model calculates heating demand, room temperatures, and thermal comfort parameters for a person in the room. The model is based on a numerical Finite Control Volume (FCV) method for the heat transfer in walls, ceiling, windows and floor. The model uses both convective and radiative heat transfer...... to the room air and between the room surfaces. The simulation model has been used to calculate heating demand and room temperature in a typical well insulated Danish single-family house with a heating demand of approximately 6000 kWh per year, for a 130 m² house. Two different types of floor heating systems...

  16. Distribution of residual long-lived radioactivity in the inner concrete walls of a compact medical cyclotron vault room.

    Science.gov (United States)

    Fujibuchi, Toshioh; Nohtomi, Akihiro; Baba, Shingo; Sasaki, Masayuki; Komiya, Isao; Umedzu, Yoshiyuki; Honda, Hiroshi

    2015-01-01

    Compact medical cyclotrons have been set up to generate the nuclides necessary for positron emission tomography. In accelerator facilities, neutrons activate the concrete used to construct the vault room; this activation increases with the use of an accelerator. The activation causes a substantial radioactive waste management problem when facilities are decommissioned. In the present study, several concrete cores from the walls, ceiling and floor of a compact medical cyclotron vault room were samples 2 years after the termination of operations, and the radioactivity concentrations of radionuclides were estimated. Cylindrical concrete cores 5 cm in diameter and 10 cm in length were bored from the concrete wall, ceiling and floor. Core boring was performed at 18 points. The gamma-ray spectrum of each sample was measured using a high-purity germanium detector. The degree of activation of the concrete in the cyclotron vault room was analyzed, and the range and tendency toward activation in the vault room were examined. (60)Co and (152)Eu were identified by gamma-ray spectrometry of the concrete samples. (152)Eu and (60)Co are produced principally from the stable isotopes of europium and cobalt by neutron capture reactions. The radioactivity concentration did not vary much between the surface of the concrete and at a depth of 10 cm. Although the radioactivity concentration near the target was higher than the clearance level for radioactive waste indicated in IAEA RS-G-1.7, the mean radioactivity concentration in the walls and floor was lower than the clearance level. The radioactivity concentration of the inner concrete wall of the medical cyclotron vault room was not uniform. The areas exceeding the clearance level were in the vicinity of the target, but most of the building did not exceed the clearance levels.

  17. Design And Implementation Of Smart Living Room Wireless Control For Safety Purpose

    OpenAIRE

    Aeindra Myint Lwin; Zaw Min Min Htun; Hla Myo Tun

    2015-01-01

    Abstract This research presents the microcontroller controlled smart living room system using Bluetooth wireless technology from mobile phone.An android apk is created in mobile for controlling the living room system. A 16F877A microcontroller is interfaced serially to a bluetooth module transceiver. It is used for controlling fan speed control dim light control lighting ONOFF and window angle control. An arduino controller is used for keypad control door security. It is connected to DC motor...

  18. Protection of occupants from exhaled infectious agents and floor material emissions in rooms with personalized and underfloor ventilation

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor

    2007-01-01

    the concentration of exhaled air pollution increased in the room. The two types of personalized ventilation performed differently. Subsequent analyses of airborne infection transmission risk indicated that personalized ventilation could become a supplement to traditional methods of infection control....... of pollutants associated with exhaled air and floor material emissions was evaluated at various combinations of personalized and underfloor airflow rates. Compared to underfloor ventilation alone, personalized and underfloor ventilation provided excellent protection Of seated occupants from any pollution, while......The performance of two personalized. ventilation systems supplying air at the breathing zone was tested in conjunction with underfloor ventilation generating two different airflow patterns in a full-scale test room. Two breathing thermal manikins were used to simulate occupants. The distribution...

  19. Simulations of floor cooling system capacity

    International Nuclear Information System (INIS)

    Odyjas, Andrzej; Górka, Andrzej

    2013-01-01

    Floor cooling system capacity depends on its physical and operative parameters. Using numerical simulations, it appears that cooling capacity of the system largely depends on the type of cooling loads occurring in the room. In the case of convective cooling loads capacity of the system is small. However, when radiation flux falls directly on the floor the system significantly increases productivity. The article describes the results of numerical simulations which allow to determine system capacity in steady thermal conditions, depending on the type of physical parameters of the system and the type of cooling load occurring in the room. Moreover, the paper sets out the limits of system capacity while maintaining a minimum temperature of the floor surface equal to 20 °C. The results are helpful for designing system capacity in different type of cooling loads and show maximum system capacity in acceptable thermal comfort condition. -- Highlights: ► We have developed numerical model for simulation of floor cooling system. ► We have described floor system capacity depending on its physical parameters. ► We have described floor system capacity depending on type of cooling loads. ► The most important in the obtained cooling capacities is the type of cooling loads. ► The paper sets out the possible maximum cooling floor system capacity

  20. Floor heating maximizes residents` comfort

    Energy Technology Data Exchange (ETDEWEB)

    Tirkkanen, P.; Wikstroem, T.

    1996-11-01

    Storing heat in floors by using economical night-time electricity does not increase the specific consumption of heating. According to studies done by IVO, the optimum housing comfort is achieved if the room is heated mainly by means of floor heating that is evened out by window or ceiling heating, or by a combination of all three forms of heating. (orig.)

  1. Safety by design: effects of operating room floor marking on the position of surgical devices to promote clean air flow compliance and minimise infection risks

    NARCIS (Netherlands)

    de Korne, Dirk F.; van Wijngaarden, Jeroen D. H.; van Rooij, Jeroen; Wauben, Linda S. G. L.; Hiddema, U. Frans; Klazinga, Niek S.

    2012-01-01

    To evaluate the use of floor marking on the positioning of surgical devices within the clean air flow in an operating room (OR) to minimise infection risk. Laminar flow clean air systems are important in preventing infection in ORs but, for optimal results, surgical devices must be correctly

  2. Investigation of floor Nusselt number in floor heating system for insulated ceiling conditions

    International Nuclear Information System (INIS)

    Karadag, Refet; Teke, Ismail

    2007-01-01

    In this study, in a floor heated room, natural convection heat transfer over the floor is analysed numerically for different thermal conditions. An equation relevant to Nusselt number over the floor has been obtained by using the numerical data. Different equations are given in the literature. They consider the effect of floor Rayleigh number while neglecting the effect of wall and ceiling thermal conditions. Numerical data obtained in this study show that the Nusselt number over the floor depends on not only the floor Rayleigh number but also the wall Rayleigh number (for insulated ceiling conditions). The equations given in the literature are different from each other due to their not considering the effect of wall and ceiling Rayleigh numbers. This difference between the equations may be eliminated by obtaining an equation containing the effect of floor, wall and ceiling Rayleigh numbers. In this new approach, an equation relevant to the floor Nusselt number that depends on the floor and wall Rayleigh numbers has been obtained in the floor heating system for insulated ceiling conditions. The equation obtained in this study has been compared with the equations given in the literature. It has been seen that the equation obtained in this study matches the numerical values under more extensive thermal conditions than the equations given in the literature. The maximum deviation for the equations given in the literature is 35%, but in the current study, the maximum deviation has been found to be 10%. As a result, it is more convenient to use the equation found in the new approach as a function of Rayleigh number over the floor and wall for insulated ceiling conditions

  3. Study protocol for the Flooring for Injury Prevention (FLIP) Study: a randomised controlled trial in long-term care.

    Science.gov (United States)

    Lachance, Chantelle C; Feldman, Fabio; Laing, Andrew C; Leung, Pet Ming; Robinovitch, Stephen N; Mackey, Dawn C

    2016-12-01

    A promising strategy for reducing the incidence and severity of fall-related injuries in long-term care (LTC) is to decrease the ground surface stiffness, and the subsequent forces applied to the body parts at impact, through installation of compliant flooring that does not substantially affect balance or mobility. Definitive evidence of the effects of compliant flooring on fall-related injuries in LTC is lacking. The Flooring for Injury Prevention (FLIP) Study is designed to address this gap. The FLIP Study is a 4-year, parallel-group, 2-arm, randomised controlled superiority trial of flooring in 150 resident rooms at a LTC site. The primary objective is to determine whether compliant flooring reduces serious fall-related injuries relative to control flooring. Intervention (2.54 cm SmartCells compliant; 74 rooms) and control (2.54 cm plywood; 76 rooms) floorings were installed over the top of existing concrete floors and covered with identical 2.00 mm vinyl. The primary outcome is serious fall-related injury, defined as any impact-related injury due to a fall in a study room that results in Emergency Department visit or hospital admission. Secondary outcomes include minor fall-related injury, any fall-related injury, falls, number of fallers, fractures, and healthcare utilisation and costs for serious fall-related injuries. Randomisation of study rooms, and residents in rooms, was stratified by residential unit, and flooring assignments were concealed. Outcome ascertainment began September 2013. Results from the FLIP Study will provide evidence about the effects of compliant flooring on fall-related injuries in LTC and will guide development of safer environments for vulnerable older adults. NCT01618786. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Acoustical Design Guidelines for Living Rooms for Adults with intellectual Disabilities

    NARCIS (Netherlands)

    Saher, K.

    2013-01-01

    The aim of this thesis is to investigate the effects of building design tools on acoustical quality parameters in living rooms for adults with intellectual disabilities (ID) and develop acoustical design guidelines for architects. This study is specifically concerned with the validation of

  5. Does apartment's distance to an in-built transformer room predict magnetic field exposure levels?

    Science.gov (United States)

    Huss, Anke; Goris, Kelly; Vermeulen, Roel; Kromhout, Hans

    2013-01-01

    It has been shown that magnetic field exposure in apartments located directly on top or adjacent to transformer rooms is higher compared with exposure in apartments located further away from the transformer rooms. It is unclear whether this also translates into exposure contrast among individuals living in these apartments. We performed spot measurements of magnetic fields in 35 apartments in 14 apartment buildings with an in-built transformer and additionally performed 24-h personal measurements in a subsample of 24 individuals. Apartments placed directly on top of or adjacent to a transformer room had on average exposures of 0.42 μT, apartments on the second floor on top of a transformer room, or sharing a corner or edge with the transformer room had 0.11 μT, and apartments located further away from the transformer room had levels of 0.06 μT. Personal exposure levels were approximately a factor 2 lower compared with apartment averages, but still showed exposure contrasts, but only for those individuals who live in the apartments directly on top or adjacent to a transformer room compared with those living further away, with 0.23 versus 0.06 μT for personal exposure when indoors, respectively. A classification of individuals into 'high' and 'low' exposed based on the location of their apartment within a building with an in-built transformer is possible and could be applied in future epidemiological studies.

  6. Long term performance of a solar floor and hot water heating house; Taiyonetsu yukadanbo kyuto jutaku no choki seino

    Energy Technology Data Exchange (ETDEWEB)

    Udagawa, M [Kogakuin University, Tokyo (Japan)

    1997-11-25

    Outlined herein are measured energy consumption followed for 12 years for a totally electrified solar house with a floor-heating and hot-water heating system. In the solar system, hot water generated by the solar collector is sent, via a surge tank, to a living room, dining room and study to heat their concrete floors, and recycled back to the collector after heating the heat-storage tank for hot water supply. The collector is of plate type, consisting of 6 units, each with a white glass sheet as the heat-collecting membrane for selectively absorbing heat. Its total heat-collecting area is 11.4m{sup 2}. Long-term performance of the solar system installed for floor and hot-water heating in a totally electrified solar house, is analyzed by the measured results collected for 12 years. The house consumes secondary energy of 11.7MWh/year on the average, which is approximately 20% lower that that required for a house of the equivalent size. The solar system has been operated smoothly, to supply 46 and 35% of the required heat for hot-water and floor heating. It is however estimated that annual heat loss reaches 34% in the hot-water heating system, including that in the electric hot-water generator, and prevention of heat loss is one of the major themes for the future system designs. 4 refs., 5 figs.

  7. An Improved Prediction Model for the Impact Sound Level of Lightweight Floors: Introducing Decoupled Floor-Ceiling and Beam-Plate Moment

    DEFF Research Database (Denmark)

    Mosharrof, Mohammad Sazzad; Brunskog, Jonas; Ljunggren, Fredrik

    2011-01-01

    the impact sound pressure level in a receiving room for a coupled floor structure where floor and ceiling are rigidly connected by beams. A theoretical model for predicting the impact sound level for a decoupled floor structure, which has no rigid mechanical connections between the floor and the ceiling......, is developed. An analytical method has been implemented, where a spatial Fourier transform method as well as the Poisson’s sum formula is applied to model transformed plate displacements. Radiated sound power was calculated from these displacements and normalized sound pressure levels were calculated in one...... and is found to be dependent on frequency, showing significant improvement in predicting impact sound level at high frequency region....

  8. Finite element analysis of high modal dynamic responses of a composite floor subjected to human motion under passive live load

    Directory of Open Access Journals (Sweden)

    Arash Behnia

    Full Text Available Light weight and long span composite floors are common place in modern construction. A critical consequence of this application is undesired vibration which may cause excessive discomfort to occupants. This work investigates the composite floor vibration behavior of an existing building based on a comprehensive study of high modal dynamic responses, the range of which has been absent in previous studies and major analytical templates, of different panels under the influence of loads induced by human motion. The resulting fundamental natural frequency and vibration modes are first validated with respect to experimental and numerical evidences from literature. Departing from close correlation established in comparison, this study explores in detail the effects of intensity of passive live load as additional stationary mass due to crowd jumping as well as considering human structure interaction. From observation, a new approach in the simulation of passive live load through the consideration of human structure interaction and human body characteristics is proposed. It is concluded that higher vibration modes are essential to determine the minimum required modes and mass participation ratio in the case of vertical vibration. The results indicate the need to consider 30 modes of vibration to obtain all possible important excitations and thereby making third harmonic of load frequency available to excite the critical modes. In addition, presence of different intensities of passive live load on the composite floor showed completely different behavior in each particular panel associated with load location of panel and passive live load intensity. Furthermore, implementing human body characteristics in simulation causes an obvious increase in modal damping and hence better practicality and economical presentation can be achieved in structural dynamic behavior.

  9. Prediction on the Enhancement of the Impact Sound Insulation to a Floating Floor with Resilient Interlayer

    Science.gov (United States)

    Huang, Xianfeng; Meng, Yao; Huang, Riming

    2017-10-01

    This paper describes a theoretical method for predicting the improvement of the impact sound insulation to a floating floor with the resilient interlayer. Statistical energy analysis (SEA) model, which is skilful in calculating the floor impact sound, is set up for calculating the reduction in impact sound pressure level in downstairs room. The sound transmission paths which include direct path and flanking paths are analyzed to find the dominant one; the factors that affect impact sound reduction for a floating floor are explored. Then, the impact sound level in downstairs room is determined and comparisons between predicted and measured data are conducted. It is indicated that for the impact sound transmission across a floating floor, the flanking path impact sound level contribute tiny influence on overall sound level in downstairs room, and a floating floor with low stiffness interlayer exhibits favorable sound insulation on direct path. The SEA approach applies to the floating floors with resilient interlayers, which are experimentally verified, provides a guidance in sound insulation design.

  10. Floor heating and cooling combined with displacement ventilation: Possibilities and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Causone, Francesco; Corgnati, Stefano P. [TEBE Research Group, Department of Energetics, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Baldin, Fabio [Department of Applied Physics, University of Padova, via Venezia 1, 35131 Padova (Italy); Olesen, Bjarne W. [ICIEE, Department of Civil Engineering, Technical University of Denmark, Nils Koppels Alle Building 402, 2800 Kgs. Lyngby (Denmark)

    2010-12-15

    Design guidelines envisage that floor heating can be used together with displacement ventilation (DV), provided that the supply air is not overly heated before it can reach heat and contaminant sources. If this is not controlled a mixing flow pattern could occur in the room. The use of floor cooling with DV is also considered possible, although draught risk at ankle level and vertical air temperature differences must be controlled carefully, because they could increase. Few studies on these topics were found in the literature. An indoor environmental chamber was set up to obtain measurements aimed at analysing the possibilities and limitations of combining floor heating/cooling with DV. Air temperature profiles, air velocity profiles, surface temperatures and ventilation effectiveness were measured under different environmental conditions that may occur in practice. These values were compared to equivalent temperature measurements obtained using a thermal manikin. The measurements show that floor heating can be used with DV, obtaining high ventilation effectiveness values. A correlation between the floor heating capacity and the air temperature profile in the room was found. Measurements showed that floor cooling does not increase draught risk at ankle level, although it does increase vertical air temperature differences. (author)

  11. Red photoluminescence of living systems at the room temperature: measurements and results

    International Nuclear Information System (INIS)

    Kudryashova, I S; Rud, V Yu; Shpunt, V Ch; Rud, Yu V; Glinushkin, A P

    2016-01-01

    Presents results of a study of the red luminescence of living plants at room temperature. The analysis of obtained results allows to conclude that the photoluminescence spectra for green leaves in all cases represent the two closely spaced bands. (paper)

  12. Simulation study on single family house with solar floor and domestic hot water heating system by EESLISM; EESLISM ni yoru taiyonetsu danbo kyuto jutaku no simulation

    Energy Technology Data Exchange (ETDEWEB)

    Roh, H; Udagawa, M [Kogakuin University, Tokyo (Japan)

    1997-11-25

    Indoor thermal conditions and energy performance were simulated, by the aid of EESLISM as a common simulation program for indoor thermal conditions and energy systems, for an actual two-storied single family house equipped with solar-heated floors and a domestic hot water (DHW) heating system, in order to investigate applicability of the simulation program. The house, built in Shibuya Ward in Tokyo, has a total floor area of 164m{sup 2}, with a living room, dining room and study heated by the solar system for a total floor area of 35m{sup 2}. A heat-storage tank is provided, dedicated to the DHW system. The solar collector is of flat type, with selectively light-absorbing planes, having a total collector area of 11.46m{sup 2}. The operating conditions of the floor-heating and DHW systems are almost reproduced. It is necessary to take surrounding conditions into consideration; solar radiation in daytime will be overestimated if adjacent buildings are neglected to give higher temperature in the space and on the wall on the south than the observed level. 6 refs., 5 figs., 1 tab.

  13. Vinyl flooring in the home is associated with children's airborne butylbenzyl phthalate and urinary metabolite concentrations.

    Science.gov (United States)

    Just, Allan C; Miller, Rachel L; Perzanowski, Matthew S; Rundle, Andrew G; Chen, Qixuan; Jung, Kyung Hwa; Hoepner, Lori; Camann, David E; Calafat, Antonia M; Perera, Frederica P; Whyatt, Robin M

    2015-01-01

    Prior studies have shown that vinyl flooring as well as the vinyl-softening plasticizers butylbenzyl phthalate (BBzP) and di(2-ethylhexyl) phthalate (DEHP) are associated with asthma and airway inflammation. Although DEHP exposure is primarily dietary, whether home vinyl flooring contributes to indoor air and urinary metabolite concentrations for these two phthalates is unclear. Exposures to BBzP and DEHP were examined in a prospective birth cohort of New York City children (n=239) using: (i) visual observation of potential phthalate containing flooring, (ii) a 2-week home indoor air sample, and (iii) concurrent urinary metabolites in a subset (n=193). The category "vinyl or linoleum" flooring was observed in 135 (56%) of monitored rooms; these rooms had statistically significantly higher indoor air geometric mean concentrations of BBzP (23.9 ng/m(3)) than rooms with wood or carpet flooring (10.6 ng/m(3)). Children from homes with "vinyl or linoleum" flooring also had significantly higher urinary BBzP metabolite concentrations than other children. Indoor air BBzP and urinary metabolite concentrations were correlated positively (Spearman's rho 0.40). By contrast, indoor air DEHP was not associated with flooring type nor with its urinary metabolite concentrations. Vinyl flooring in the home may be an important source of children's exposure to BBzP via indoor air.

  14. Environmental Health and Safety Hazards Experienced by Home Health Care Providers: A Room-by-Room Analysis.

    Science.gov (United States)

    Polivka, Barbara J; Wills, Celia E; Darragh, Amy; Lavender, Steven; Sommerich, Carolyn; Stredney, Donald

    2015-11-01

    The number of personnel providing in-home health care services is increasing substantially. The unique configuration of environmental hazards in individual client homes has a significant impact on the safety and health of home health care providers (HHPs). This mixed-methods study used data from a standardized questionnaire, focus groups, and individual interviews to explore environmental health and safety hazards encountered by HHPs in client homes. The participant sample (N = 68) included nurses, aides, therapists, and owners/managers from a variety of geographic locations. The most often-reported hazards were trip/slip/lift hazards, biohazards, and hazards from poor air quality, allergens, pests and rodents, and fire and burns. Frequency of identified key hazards varied by room, that is, kitchen (e.g., throw rugs, water on floor), bathroom (e.g., tight spaces for client handling), bedroom (e.g., bed too low), living room (e.g., animal waste), and hallway (e.g., clutter). Findings indicate the need for broader training to enable HHPs to identify and address hazards they encounter in client homes. © 2015 The Author(s).

  15. Investigating the fall-injury reducing effect of impact absorbing flooring among female nursing home residents: initial results.

    Science.gov (United States)

    Gustavsson, Johanna; Bonander, Carl; Andersson, Ragnar; Nilson, Finn

    2015-10-01

    Fall-related injuries affect the lives of elderly to a substantial degree. This quasi-experimental study investigates the fall-injury reducing effect of impact absorbing flooring among female nursing home residents. The intervention site is a nursing home in Sweden where impact absorbing flooring was installed in parts of one of six wards (six out of 10 apartments (excluding bathrooms), the communal dining-room and parts of the corridor). The impact absorbing flooring is a 12 mm thick closed cell flexible polyurethane/polyurea composite tile (500×500 mm) with an exterior surface of polyurethane/polyurea. A generalised linear model (log-binomial) was used to calculate the RR of injury from falls on impact absorbing flooring compared to falls on regular flooring, adjusted for age, body mass index, visual and cognitive impairments. During the study period (1 October 2011 to 31 March 2014), 254 falls occurred on regular flooring and 77 falls on impact absorbing flooring. The injury/fall rate was 30.3% for falls on regular flooring and 16.9% for falls on impact absorbing flooring. Adjusted for covariates, the impact absorbing flooring significantly reduced the RR of injury in the event of a fall by 59% (RR 0.41 (95% Cl 0.20 to 0.80)). This is, to our knowledge, the first study evaluating the injury-reducing effect of impact absorbing flooring in a nursing home showing statistically significant effect. The results from this study are promising, indicating the considerable potential of impact absorbing flooring as a fall-related injury intervention among frail elderly. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Vinyl flooring in the home is associated with children’s airborne butylbenzyl phthalate and urinary metabolite concentrations

    Science.gov (United States)

    Just, Allan C.; Miller, Rachel L.; Perzanowski, Matthew S.; Rundle, Andrew G.; Chen, Qixuan; Jung, Kyung Hwa; Hoepner, Lori; Camann, David E.; Calafat, Antonia M.; Perera, Frederica P.; Whyatt, Robin M.

    2015-01-01

    Prior studies have shown that vinyl flooring, as well as the vinyl-softening plasticizers butylbenzyl phthalate (BBzP) and di(2-ethylhexyl) phthalate (DEHP), are associated with asthma and airway inflammation. While DEHP exposure is primarily dietary, whether home vinyl flooring contributes to indoor air and urinary metabolite concentrations for these two phthalates is unclear. Exposures to BBzP and DEHP were examined in a prospective birth cohort of New York City children (n=239) using: (1) visual observation of potential phthalate containing flooring, (2) a two-week home indoor air sample, and (3) concurrent urinary metabolites in a subset (n=193). The category “vinyl or linoleum” flooring was observed in 135 (56%) of monitored rooms; these rooms had statistically significantly higher indoor air geometric mean concentrations of BBzP (23.9 ng/m3) than rooms with wood or carpet flooring (10.6 ng/m3). Children from homes with “vinyl or linoleum” flooring also had significantly higher urinary BBzP metabolite concentrations than other children. Indoor air BBzP and urinary metabolite concentrations were correlated positively (Spearman’s rho 0.40). By contrast, indoor air DEHP was not associated with flooring type nor with its urinary metabolite concentrations. Vinyl flooring in the home may be an important source of children’s exposure to BBzP via indoor air. PMID:25690585

  17. Performance Evaluation of Radiator and Radiant Floor Heating Systems for an Office Room Connected to a Ground-Coupled Heat Pump

    Directory of Open Access Journals (Sweden)

    Ioan Sarbu

    2016-03-01

    Full Text Available A ground-coupled heat pump (GCHP system used to provide the space heating for an office room is a renewable, high performance technology. This paper discusses vapour compression-based HP systems, briefly describing the thermodynamic cycle calculations, as well as the coefficient of performance (COP and CO2 emissions of a HP with an electro-compressor and compares different heating systems in terms of energy consumption, thermal comfort and environmental impact. It is focused on an experimental study performed to test the energy efficiency of the radiator or radiant floor heating system for an office room connected to a GCHP. The main performance parameters (COP and CO2 emissions are obtained for one month of operation of the GCHP system, and a comparative analysis of these parameters is presented. Additionally, two numerical simulation models of useful thermal energy and the system COP in heating mode are developed using the Transient Systems Simulation (TRNSYS software. Finally, the simulations obtained from TRNSYS software are analysed and compared to the experimental data, showing good agreement and thus validating the simulation models.

  18. Design And Implementation Of Smart Living Room Wireless Control For Safety Purpose

    Directory of Open Access Journals (Sweden)

    Aeindra Myint Lwin

    2015-07-01

    Full Text Available Abstract This research presents the microcontroller controlled smart living room system using Bluetooth wireless technology from mobile phone.An android apk is created in mobile for controlling the living room system. A 16F877A microcontroller is interfaced serially to a bluetooth module transceiver. It is used for controlling fan speed control dim light control lighting ONOFF and window angle control. An arduino controller is used for keypad control door security. It is connected to DC motor control circuit and switching circuit for opening and closing of the door keypad for entering password and serial LCD for displaying the update status of the door.User can control the home appliances by using bluetooth connection from mobile phone in its range. User can adjust the dim light fan speed window angle and light bulbs from android apk. An internal EEPROM is built in 16F877A microcontroller and it stores the last requested data of the appliances. If userwants to recover the former conditions of the appliances he can recall them from android apk.

  19. The effects of receiving room dimensions and absorption in the measurement of impact insulation class (IIC) rating

    Science.gov (United States)

    Su, Rose Mary; Tocci, Gregory

    2005-09-01

    The measurement of the Impact Insulation Class (IIC) rating of any floor/ceiling construction requires the use of a certified laboratory space. In a recent investigation into the IIC rating of a new floor system, several tests were conducted in a certified laboratory. In many tests, the IIC rating was controlled by the 100-Hz 1/3-octave frequency band, despite changes in the floor/ceiling construction. The base floor/ceiling construction included a wood structural floor on open-web wood joists and a GWB ceiling below. This paper will investigate the possibility that room resonances influenced the IIC ratings of the several floor systems tested. These data will be compared with IIC data collected for the same floor construction with the GWB ceiling removed. The removal of the GWB ceiling increased the receiver room volume and exposed the glass fiber insulation to the receiver room, thus eliminating the control of the 100-Hz 1/3-octave band over the IIC rating.

  20. Nuclear reactor control room construction

    International Nuclear Information System (INIS)

    Lamuro, R.C.; Orr, R.

    1993-01-01

    A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures

  1. Performance and organ morphology of broilers fed microbial or antimicrobial additives and raised in batteries or floor pens

    Directory of Open Access Journals (Sweden)

    Pedroso AA

    2003-01-01

    Full Text Available This study was conducted to determine the effect of microbial or antimicrobial additives on the performance and organ morphology of broilers raised in batteries or in floor pens. The effect of microbial additives on the presence of oocysts in the litter was also studied. Experiments 1 and 2 consisted of four treatments (non-supplemented control diet or diet supplemented with avilamycin, bacitracin methylene disalicylate or enramycin and six repetitions in a randomized block design. In Experiment 1, 288 day-old chicks were housed in heated batteries in a environmentally controlled room, 12 chicks per cage; in Experiment 2, 1,200 day-old chicks were housed in a curtain-sided experimental house, with concrete floor and rice hulls as litter material, 50 chicks per pen. Experiments 3 and 4 were carried out similarly to Experiments 1 and 2, respectively, but the treatments consisted of microbial additives (non-supplemented control diet or Bacillus subtilis added to the feed plus Lactobacillus reuteri and Lactobacillus johnsonii added to the water, undefined microflora added to the water or live yeast added to the feed. The antibiotics did not affect the performance of birds raised in batteries, but improved feed conversion, weight gain and live weight when chickens were kept on the floor pens. Microbial additives did not affect bird performance in any environment; however, treatments affected liver weight. Microbial agents increased intestinal weight in floor-raised broilers. No relationship was seen between the use of microbial additives and the presence of oocysts in the litter.

  2. Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar ., S. C.; Melikov, Arsen Krikor

    2011-01-01

    A comprehensive study comprising physical measurements and human subject experiments was conducted to explore the potential for improving occupants' thermal comfort and indoor air quality (IAQ) using a personalized ventilation (PV) system combined with an under-floor air distribution(UFAD) system....... The integrated PV-UFAD system, when operated at relatively high temperature of the air supplied from the UFAD system, provided comfortable cooling of the facial region, improved inhaled air quality, and decreased the risk of "cold feet," which is often reported in rooms with UFAD alone. This article explores...... and a secondary AHU for 100% recirculated air that is supplied through UFAD outlets. Velocity and temperature distribution in the chamber were measured. A breathing thermal manikin was used to measure the heat loss from 26 body segments and to determine the equivalent temperature. The responses of 30 human...

  3. Coatings and floor covers for nuclear applications

    International Nuclear Information System (INIS)

    Kunze, S.

    1998-01-01

    To prevent damage to, or even the destruction of, components of very sensitive electrical equipment in rooms in which unsealed radioactive emitters are handled, floors must be antistatic and capable of being decontaminated. Conductive additives to the cover compounds achieve the desired leakage resistance of 5.10 4 to 10 6 Ω. Investigations have shown the decontamination capability of all floor covers and coatings to be excellent in most cases, and good in a few cases. Except for one coating, the coatings examined after radiation exposure also meet the requirements applying to nuclear installations. (orig.) [de

  4. Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    vertical air temperature differences and air velocities for different hybrid systems are less than 3 C and 0.2 m/s when supply air temperature is 19 C, air change rate is 4.2 h-1, and heated surface temperature of floor/ceiling heating system is 25 C. Ventilation effectiveness of mixing ventilation system...... combined with floor/ceiling heating systems is approximately equal to 1.0, and ventilation effectiveness of displacement ventilation system combined with floor/ceiling heating systems ranges from 1.0 to 1.2. The floor/ceiling heating systems combined with mixing ventilation system have more uniform indoor...... air distribution but smaller ventilation effectiveness compared with the floor/ceiling heating systems combined with displacement ventilation system. With regard to the building heat loss increased by non-uniform indoor air distribution and small ventilation effectiveness, there should be an optimal...

  5. Generation of airborne Listeria innocua from model floor drains.

    Science.gov (United States)

    Berrang, Mark E; Frank, Joseph F

    2012-07-01

    Listeria monocytogenes can colonize floor drains in poultry processing and further processing facilities, remaining present even after cleaning and disinfection. Therefore, during wash down, workers exercise caution to avoid spraying hoses directly into drains in an effort to prevent the escape and transfer of drain microflora to food contact surfaces. The objective of this study was to examine the extent to which an inadvertent water spray into a colonized floor drain can cause the spread of airborne Listeria. Listeria innocua was used to inoculate a polyvinyl chloride model floor drain, resulting in approximately 10(8) cells per ml of phosphate-buffered saline and 10(4) attached cells per square centimeter of inner surface. Each model drain was subjected to a 2-s spray of tap water at 68.9 kPa from a distance of 1 m. Drains were sprayed while filled and again after emptying. Airborne cells were collected by using sedimentation plates containing Listeria selective agar which were placed on the floor and walls of a contained room at incremental horizontal and vertical distances of 0.6, 1.2, 2.4, or 4.0 m from the drain. Sedimentation plates were exposed for 10 min. A mechanical sampler was used to also collect air by impaction on the surface of Listeria selective agar to determine the number of cells per liter of air. The experiment was conducted in triplicate rooms for each of four replications. L. innocua was detected on sedimentation plates on the floor as far as 4.0 m from the drain and on walls as high as 2.4 m above the floor and 4 m from the drain. A 2-s spray with a water hose into a contaminated drain can cause airborne spread of Listeria, resulting in the potential for cross-contamination of food contact surfaces, equipment, and exposed product.

  6. Effects of floor cooling during high ambient temperatures on the lying behavior and productivity of growing finishing pigs

    NARCIS (Netherlands)

    Huynh Thi Thanh Thuy,; Aarnink, A.J.A.; Spoolder, H.A.M.; Verstegen, M.W.A.; Kemp, B.

    2004-01-01

    Given that exposing rapidly growing pigs to high ambient temperatures can induce heat stress, which reduces their welfare and production, this study looked at the influence of floor cooling on pigs¿ behavior and performance. Pens in room 1 had a solid floor (60%) and a metal slatted floor (40%). The

  7. Comparison of performance of simulation models for floor heating

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Svendsen, Svend

    2005-01-01

    This paper describes the comparison of performance of simulation models for floor heating with different level of detail in the modelling process. The models are compared in an otherwise identical simulation model containing room model, walls, windows, ceiling and ventilation system. By exchanging...

  8. Evaluation of the thermal comfort of ceramic floor tiles

    Directory of Open Access Journals (Sweden)

    Carmeane Effting

    2007-09-01

    Full Text Available In places where people are bare feet, the thermal sensation of cold or hot depends on the environmental conditions and material properties including its microstructure and crustiness surface. The uncomforting can be characterized by heated floor surfaces in external environments which are exposed to sun radiation (swimming polls areas or by cold floor surfaces in internal environments (bed rooms, path rooms. The property named thermal effusivity which defines the interface temperature when two semi-infinite solids are putted in perfect contact. The introduction of the crustiness surface on the ceramic tiles interferes in the contact temperature and also it can be a strategy to obtain ceramic tiles more comfortable. Materials with low conductivities and densities can be obtained by porous inclusion are due particularly to the processing conditions usually employed. However, the presence of pores generally involves low mechanical strength. This work has the objective to evaluate the thermal comfort of ceramics floor obtained by incorporation of refractory raw materials (residue of the polishing of the porcelanato in industrial atomized ceramic powder, through the thermal and mechanical properties. The theoretical and experimental results show that the porosity and crustiness surface increases; there is sensitive improvement in the comfort by contact.

  9. Experimental evaluation of air distribution in mechanically ventilated residential rooms

    DEFF Research Database (Denmark)

    Tomasi, R.; Krajčík, M.; Simone, A.

    2013-01-01

    The effect of low ventilation rates (1 or 0.5 air change per hour) on thermal comfort and ventilation effectiveness was experimentally studied in a simulated residential room equipped with radiant floor heating/cooling and mixing ventilation systems. The tests were performed for various positions...... of supply and extract air terminals and different winter and summer boundary conditions. Vertical air temperature, operative temperature and air velocity profiles were measured in different positions in the room, and equivalent temperatures were derived, in order to characterize thermal comfort. Contaminant...... with unconditioned outdoor air supply, i.e. at the supply air temperatures higher than the room air temperature. Moreover, low floor temperatures were needed to maintain the desired reference temperature in the stratified thermal environment. Mainly in cooling conditions the ventilation effectiveness depended...

  10. Locating room air-conditioners at floor level for energy saving in residential buildings

    International Nuclear Information System (INIS)

    Gao, C.F.; Lee, W.L.; Chen Hua

    2009-01-01

    Residential air-conditioning becomes a common feature in our daily life. They are typically installed at high level known as ceiling-based system (CAC). With the increasing use of floor-based air-conditioning system in commercial buildings for energy saving, it is proposed in this study to locate a top discharge/front return air-conditioner at floor level to resemble a floor-based air-conditioning system (FAC) to curb energy use in residential buildings. Given the concerns about draught discomfort and thermal stratification associated with floor-based air-conditioning systems, the objective of this study is to evaluate the air distribution performance and to quantify the possible energy benefits. Bedroom was chosen as a sensitive case for detailed air distribution performance evaluation. Experimental study, CFD simulations and energy simulations were conducted in achieving the specific objectives. CAC and FAC were installed in a bedroom-like environmental chamber for experimental study at different indoor and outdoor conditions. The air velocities and temperatures at various positions and levels inside the chamber were measured to determine the air distribution performance indices (ADPI) and airflow draft risk (DR). The cooling output, power consumption and coefficient of performance (COP) of the two units were measured and calculated for comparison. The experimental results show that ADPI of CAC and FAC are 92.3% and 84.6%, respectively. COP of FAC is 8.11% higher than CAC, and the corresponding DR are comparable. The experimental results were used to validate the CFD simulations as well as providing actual performance data for predicting the energy use of applying CAC and FAC in a case-study building. CFD simulations and draught assessment confirmed that there is no potential draught discomfort and thermal stratification associated with the use of FAC. Energy simulations predicted that the associated energy saving is 6.9%. Wider use of FAC in residential

  11. Experimental Investigation of the Influence of Different Flooring Emissivity on Night-Time Cooling using Displacement Ventilation

    DEFF Research Database (Denmark)

    Le Dréau, Jérôme; Karlsen, Line Røseth; Litewnicki, Michal

    2011-01-01

    , but it was seen that the emissivity of the flooring affected the heat transfer ratio at the internal surfaces. The convective heat flux increased at the ceiling and decreased at the floor for experiments with aluminum flooring compared to the experiments with EPS floor. Temperature efficiency was slightly higher......-time ventilation using displacement ventilation. Experimental work was conducted on the basis of the work performed by Artmann et al. (2009) in a similar previous study. An aluminum-foil floor cover was installed in a full scale test room. Experimental results obtained with aluminum flooring were compared...... to results obtained by Artmann et al. with a flooring consisting of expanded polystyrene (EPS). Results showed that the surface temperature of the floor decreased with decreasing emissivity. Mean convective heat fluxes were similar for experiments conducted with both EPS and aluminum-foil floor cover...

  12. Plane Stratified Flow in a Room Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Nickel, J.; Baron, D. J. G.

    2004-01-01

    The air movement in the occupied zone of a room ventilated by displacement ventilation exists as a stratified flow along the floor. This flow can be radial or plane according to the number of wall-mounted diffusers and the room geometry. The paper addresses the situations where plane flow...

  13. Migration of DEHP and DINP into dust from PVC flooring products at different surface temperature.

    Science.gov (United States)

    Jeon, Seunghwan; Kim, Ki-Tae; Choi, Kyungho

    2016-03-15

    Phthalates are important endocrine disrupting chemicals that have been linked to various adverse human health effects. Phthalates are ubiquitously present in indoor environment and could enter humans. Vinyl or PVC floorings have been recognized as one of important sources of phthalate release to indoor environment including house dust. In the present study, we estimated the migration of di(2-ethylhexyl)phthalate (DEHP) and di-isononyl phthalate (DINP) from the flooring materials into the dust under different heating conditions. For this purpose, a small chamber specifically designed for the present study and a Field and Laboratory Emission Cell (FLEC) were used, and four major types of PVC flooring samples including two UV curing paint coated, an uncoated residential, and a wax-coated commercial type were tested. Migration of DEHP was observed for an uncoated residential type and a wax-coated commercial type flooring. After 14 days of incubation, the levels of DEHP in the dust sample was determined at room temperature on average (standard deviation) at 384 ± 19 and 481 ± 53 μg/g, respectively. In contrast, migration of DINP was not observed. The migration of DEHP was strongly influenced by surface characteristics such as UV curing coating. In the residential flooring coated with UV curing paint, migration of DEHP was not observed at room temperature. But under the heated condition, the release of DEHP was observed in the dust in the FLEC. Migration of DEHP from flooring materials increased when the flooring was heated (50 °C). In Korea, heated flooring system, or 'ondol', is very common mode of heating in residential setting, therefore the contribution of PVC flooring to the total indoor DEHP exposure among general population is expected to be greater especially during winter season when the floor is heated. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Floor Heating with Displacement Ventilation: An Experimental and Numerical Analysis

    DEFF Research Database (Denmark)

    Causone, Francesco; Olesen, Bjarne W.; Corgnati, S.P.

    2010-01-01

    The effect of floor heating combined with displacement ventilation (DV) on thermal indoor environments and indoor air quality (IAQ) was studied by means of CFD. The numerical model was validated with experimental data. A typical office room was simulated, and one of the occupants was considered...... to simulate different kinds of contaminant sources, under the same boundary conditions. It was found that DV does not guarantee a better IAQ than full mixing when contaminant sources are not linked to heat sources, even when floor heating is used. Contaminants produced by powerful heat sources require high...

  15. Deflection of resilient materials for reduction of floor impact sound.

    Science.gov (United States)

    Lee, Jung-Yoon; Kim, Jong-Mun

    2014-01-01

    Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor.

  16. Locating room air-conditioners at floor level for energy saving in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gao, C.F.; Lee, Hua; Chen, W.L. [Department of Building Services Engineering, Hong Kong Polytechnic University, Hung Hom (China)

    2009-08-15

    Residential air-conditioning becomes a common feature in our daily life. They are typically installed at high level known as ceiling-based system (CAC). With the increasing use of floor-based air-conditioning system in commercial buildings for energy saving, it is proposed in this study to locate a top discharge/front return air-conditioner at floor level to resemble a floor-based air-conditioning system (FAC) to curb energy use in residential buildings. Given the concerns about draught discomfort and thermal stratification associated with floor-based air-conditioning systems, the objective of this study is to evaluate the air distribution performance and to quantify the possible energy benefits. Bedroom was chosen as a sensitive case for detailed air distribution performance evaluation. Experimental study, CFD simulations and energy simulations were conducted in achieving the specific objectives. CAC and FAC were installed in a bedroom-like environmental chamber for experimental study at different indoor and outdoor conditions. The air velocities and temperatures at various positions and levels inside the chamber were measured to determine the air distribution performance indices (ADPI) and airflow draft risk (DR). The cooling output, power consumption and coefficient of performance (COP) of the two units were measured and calculated for comparison. The experimental results show that ADPI of CAC and FAC are 92.3% and 84.6%, respectively. COP of FAC is 8.11% higher than CAC, and the corresponding DR are comparable. The experimental results were used to validate the CFD simulations as well as providing actual performance data for predicting the energy use of applying CAC and FAC in a case-study building. CFD simulations and draught assessment confirmed that there is no potential draught discomfort and thermal stratification associated with the use of FAC. Energy simulations predicted that the associated energy saving is 6.9%. Wider use of FAC in residential

  17. Navier-Stokes Simulation of Airconditioning Facility of a Large Modem Computer Room

    Science.gov (United States)

    2005-01-01

    NASA recently assembled one of the world's fastest operational supercomputers to meet the agency's new high performance computing needs. This large-scale system, named Columbia, consists of 20 interconnected SGI Altix 512-processor systems, for a total of 10,240 Intel Itanium-2 processors. High-fidelity CFD simulations were performed for the NASA Advanced Supercomputing (NAS) computer room at Ames Research Center. The purpose of the simulations was to assess the adequacy of the existing air handling and conditioning system and make recommendations for changes in the design of the system if needed. The simulations were performed with NASA's OVERFLOW-2 CFD code which utilizes overset structured grids. A new set of boundary conditions were developed and added to the flow solver for modeling the roomls air-conditioning and proper cooling of the equipment. Boundary condition parameters for the flow solver are based on cooler CFM (flow rate) ratings and some reasonable assumptions of flow and heat transfer data for the floor and central processing units (CPU) . The geometry modeling from blue prints and grid generation were handled by the NASA Ames software package Chimera Grid Tools (CGT). This geometric model was developed as a CGT-scripted template, which can be easily modified to accommodate any changes in shape and size of the room, locations and dimensions of the CPU racks, disk racks, coolers, power distribution units, and mass-storage system. The compute nodes are grouped in pairs of racks with an aisle in the middle. High-speed connection cables connect the racks with overhead cable trays. The cool air from the cooling units is pumped into the computer room from a sub-floor through perforated floor tiles. The CPU cooling fans draw cool air from the floor tiles, which run along the outside length of each rack, and eject warm air into the center isle between the racks. This warm air is eventually drawn into the cooling units located near the walls of the room. One

  18. Using a Zonal Model To Assess the Effect of a Heated Floor on Thermal Comfort Quality

    International Nuclear Information System (INIS)

    Boukhris, Yosr; Gharbi, Leila; Ghrab-Morcos, Nadia

    2009-01-01

    People s perceptions of indoor air quality and thermal comfort are affected by air speed and temperature. We have extended the three-dimensional zonal model, ZAER, to be able to predict the temperature fields and the air distributions between and within rooms in the case of natural convection. This paper presents an application of the new zonal model dealing with the influence of a heated floor of one room upon the winter thermal comfort of an unconditioned Tunisian dwelling. Coupling ZAER with a thermal comfort model allows the assessment of the thermal quality of the dwelling through the prediction of a comfort indicator. The obtained results show that a heated floor can be a useful component to improve thermal comfort in the Tunisian context, even in another room

  19. Pelvic Floor Physical Therapy for Vulvodynia: A Clinician's Guide.

    Science.gov (United States)

    Prendergast, Stephanie A

    2017-09-01

    Vulvar pain affects up to 20% of women at some point in their lives, and most women with vulvar pain have associated pelvic floor impairments. Pelvic floor dysfunction is associated with significant functional limitations in women by causing painful intercourse and urinary, bowel, and sexual dysfunction. A quick screening of the pelvic floor muscles can be performed in the gynecology office and should be used when patients report symptoms of pelvic pain. It is now known the vulvar pain syndromes are heterogeneous in origin; therefore, successful treatment plans are multimodal and include physical therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Floor interaction

    DEFF Research Database (Denmark)

    Petersen, Marianne Graves; Krogh, Peter; Ludvigsen, Martin

    2005-01-01

    Within architecture, there is a long tradition of careful design of floors. The design has been concerned with both decorating floors and designing floors to carry information. Ubiquitous computing technology offers new opportunities for designing interactive floors. This paper presents three...... different interactive floor concepts. Through an urban perspective it draws upon the experiences of floors in architecture, and provides a set of design issues for designing interactive floors....

  1. Building for changing-rooms, laundry, laboratories

    International Nuclear Information System (INIS)

    Nemeth, L.; Mezes, J.; Gulyas, F.; Hejj, A.; Matyas, J.

    1979-01-01

    This building accomodates important service sections of the power plant. The changing-rooms of the primary circuit are here, through which the employees, under the supervision of health physics service, pass to the radioactive contaminated jobs. Working-clothes are cleaned in laundries located on the ground-floor. The building houses the health measurement control rooms of the four reactor sets and the control centre of the power plant. The laboratories dealing with process control, electrical engineering, radiology, dosimetry, material tests and reactor physics will be located here. (author)

  2. Modelling of Air Flow trough a Slatted Floor by CFD

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Bjerg, Bjarne; Morsing, Svend

    In this paper two different CFD-approaches are investigated to model the airflow through a slatted floor. Experiments are carried out in a full-scale test room. The computer simulations are carried out with the CFD-code FLOVENT, which solves the time-averaged Navier-Stokes equations by use of the k...

  3. Perceived floor slipperiness and floor roughness in a gait experiment.

    Science.gov (United States)

    Yu, Ruifeng; Li, Kai Way

    2015-01-01

    Slips and falls contribute to occupational injuries and fatalities globally. Both floor slipperiness and floor roughness affect the occurrence of slipping and falling. Investigations on fall-related phenomena are important for the safety and health of workers. The purposes of this study were to: compare the perceived floor slipperiness before and after walking on the floor; compare the perceived floor slipperiness with and without shoes for males and females; discuss the perceived floor roughness based on barefoot walking; and establish regression models to describe the relationship between perceived floor slipperiness and actual friction of the floors. Male and female subjects walked on 3 m walkways with or without shoes. The perceived floor slipperiness ratings both before and after their walk were collected. The perceived floor slipperiness both before and after walking were significantly affected by both floor and surface conditions. Gender, floor, surface, and footwear conditions were all significant factors affecting the adjustment of perceived floor slipperiness. The subjects made more adjustment on perceived floor slipperiness rating when they had shoes on than when they were barefooted. Regression models were established to describe the relationship between perceived floor slipperiness and floor coefficient of friction. These models may be used to estimate perceived floor slipperiness, or in reverse, the coefficient of friction of the floor, so as to prevent slipping and falling in workplaces.

  4. Decontamination of the chemical crane room and decontamination and decommissioning of the extraction chemical room at the West Valley Demonstration Project

    International Nuclear Information System (INIS)

    Phillips, E.C.; Golden, M.P.

    1986-01-01

    This paper describes the decontamination of the Chemical Crane Room (CCR) of the West Valley Plant and the Extraction Chemical Room (XCR) from radioactively contaminated conditions to essentially shirt sleeve environments. In both cases, subsequent use re-contaminated the rooms. Prior to decontamination, general exposure rates in the CCR were 50 to 100 mR/hr with hot spots as high as 2000 mR/hr. Smearable levels on the floor were in the range of 10 5 to 10 6 dpm per 100/cm 2 . Respiratory protection was mandatory for entry. In the Extraction Chemical Room (XCR) prior to decontamination and decommissioning (D/D), radiological surveys indicated a maximum radiation field of 5 mR/hr, due to sources internal to the room, and 20,000 dpm beta/100 cm 2 surface contamination. A radiation source external to the XCR caused a hot spot with a 9 mR/hr exposure rate inside the XCR. The CCR, located at the north end of the Chemical Process Cell (CPC) is for the storage and servicing of two bridge cranes used in the CPC. Decontamination and exposure reduction in the CCR has been completed using vacuum cleaning, damp wipe down, and surface grinding followed by shielding and painting. The decontamination and decommissioning of the Extraction Chemical Room (XCR), located on the fifth floor elevation (160') of the reprocessing plant at the WVDP, has been completed. D/D operations included removal of piping, tanks, supports, and equipment to provide a clean work area of about 3000 square feet and 17 feet high

  5. Dual-stiffness flooring: can it reduce fracture rates associated with falls?

    Science.gov (United States)

    Knoefel, Frank; Patrick, Louise; Taylor, Jodie; Goubran, Rafik

    2013-04-01

    Falls cause significant morbidity and mortality in long term care facilities. Dual-stiffness flooring (DSF) has previously shown promise in reducing such morbidity in experimental models. This study set out to measure the impact of SmartCell flooring on falls-related morbidity in a nursing home. All falls occurring at an Arizona nursing home between July 1, 2008, and December 31, 2010, were reviewed for age, sex, diagnosis of osteoporosis, number of medications, history of previous falls, type of flooring (normal vs DSF), time of day, type of injury, and resulting actions. Fall-related outcomes were compared across room types using chi-square and logistic regression methods. Eighty-two falls on the DSF were compared with 85 falls on the regular floor. There was a tendency for residents falling on DSF to have less bruising and abrasions, while having more redness and cuts. There were 2 fractures on regular flooring (2.4% fracture rate) and none on the DSF flooring (0% fracture rate). The fracture rate of 2.4% of falls on the regular floor is consistent with previous reports in the literature, whereas a 0% rate found on the DSF floor is a clinically significant improvement. This suggests that DSF may be a practical approach for institutions and consumers to reduce fall-related injuries. A larger scale controlled study to confirm these encouraging preliminary findings is warranted. Copyright © 2013 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.

  6. Study on the living environment of semi-underground room with attached green house; Fusetsu onshitsu no aru hanchikashitsu no kyojusei ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T; Tsukayama, N [Ochanomizu University, Tokyo (Japan)

    1996-10-27

    In response to demand for the expansion of living space, the living environment of semi-underground room has been investigated. An attached green house (passive solar house) is adjacent to the semi-underground room. This is reinforced concrete construction, having flat type solar collector on its roof and lighting window in its north side. It does not have artificial air conditioners. Based on the measurements of daylight factor, artificial lighting is not required at the window in the daytime, but it is desirable to use daylight and artificial lighting together at the center. The performance of sound insulation depends on the high performance soundproof sash level. There is less daily temperature variation due to its large heat capacity, and less yearly temperature variation than the outside. By shielding the solar radiation, the insolation in the green house in summer can be restricted in the same as in winter. The insolation can be easily received in winter due to its large vertical intensity of solar radiation. The green house in the south side is useful for improving the living environment of semi-underground room. The temperature rise in the semi-underground room can be restricted by opening window in summer. It is desirable for the comfortable living to use artificial cooling to reduce the daytime temperature by 3 to 4{degree}C. In winter, it is comfortable to heat by 4 to 5{degree}C. 2 refs., 7 figs.

  7. Predicting Residential Exposure to Phthalate Plasticizer Emitted from Vinyl Flooring - A Mechanistic Analysis

    Science.gov (United States)

    A two-room model is developed to estimate the emission rate of di-2-ethylhexyl phthalate (DEHP) from vinyl flooring and the evolving gas-phase and adsorbed surface concentrations in a realistic indoor environment. Adsorption isotherms for phthalates and plasticizers on interior ...

  8. Air distribution and ventilation effectiveness in an occupied room heated by warm air

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Olesen, Bjarne W.

    2012-01-01

    and at different simulated outside conditions, internal heat gains and air change rates. Floor heating was also simulated and compared with the warm air heating system. Vertical air temperature profiles, air velocity profiles and equivalent temperatures were derived in order to describe the thermal environment...... floor heating system was simulated, the cooler ventilation air introduced to the room mixed well and created uniform conditions with a ventilation effectiveness of about 1.......Air distribution, ventilation effectiveness and thermal environment were experimentally studied in a simulated room in a low-energy building heated and ventilated by warm air supplied by a mixing ventilation system. Measurements were performed for various positions of the air terminal devices...

  9. The effect of floor type on the performance, cleanliness, carcass characteristics and meat quality of dairy origin bulls.

    Science.gov (United States)

    Murphy, V S; Lowe, D E; Lively, F O; Gordon, A W

    2018-05-01

    The aim of this study was to evaluate the effect of using different floor types to accommodate growing and finishing beef cattle on their performance, cleanliness, carcass characteristics and meat quality. In total, 80 dairy origin young bulls (mean initial live weight 224 kg (SD=28.4 kg)) were divided into 20 blocks with four animals each according to live weight. The total duration of the experimental period was 204 days. The first 101 days was defined as the growing period, with the remainder of the study defined as the finishing period. Cattle were randomly assigned within blocks to one of four floor type treatments, which included fully slatted flooring throughout the entire experimental period (CS); fully slatted flooring covered with rubber strips throughout the entire experimental period (RS); fully slatted flooring during the growing period and moved to a solid floor covered with straw bedding during the finishing period (CS-S) and fully slatted flooring during the growing period and moved to fully slatted flooring covered with rubber strips during the finishing period (CS-RS). Bulls were offered ad libitum grass silage supplemented with concentrates during the growing period. During the finishing period, bulls were offered concentrates supplemented with chopped barley straw. There was no significant effect of floor type on total dry matter intake (DMI), feed conversion ratio, daily live weight gain or back fat depth during the growing and finishing periods. Compared with bulls accommodated on CS, RS and CS-RS, bulls accommodated on CS-S had a significantly lower straw DMI (Pcarcass characteristics or meat quality. However, bulls accommodated on CS-S had a tendency for less channel, cod and kidney fat (P=0.084) compared with those accommodated on CS, RS and CS-RS. Overall, floor type had no effect on the performance, cleanliness, carcass characteristics or meat quality of growing or finishing beef cattle.

  10. Criteria of choosing building structures for rooftop boiler rooms

    Directory of Open Access Journals (Sweden)

    Plotnikov Artyom

    2018-01-01

    Full Text Available The paper investigates parameters of noise and vibration distribution in the territory of residential area depending on the structural materials and power of independent heat supply systems. Rooftop boiler rooms are decentralized heat supply systems in buildings. Today, residential areas are strongly affected by noise and vibrations. Adverse effects are isolated by buildings materials, protective shields and floating floors. Rooftop boiler rooms located in Tyumen city were investigated within this research. Structures of rooftop boiler rooms were analyzed. Acoustic analysis results and the parameters of equivalent continuous sound level are presented. An option for improvement of rooftop boiler rooms structures is suggested. Comparison of capital investments in construction and installation activities is carried out. Conclusion on capital investments required for noise protection is made.

  11. Asilo de ancianos, en Kressbronn (Alemania

    Directory of Open Access Journals (Sweden)

    Beck-Erlang, Wilfrled

    1965-12-01

    Full Text Available The basement of this building contains the boiler room, the fuel storage, and ancillaries. The ground floor has a main vestibule, offices, guest rooms, general store room. There is also a chapel where 150 people can have seating accommodation. The second floor includes dining room, kitchen, living room, the manager's quarters and three double rooms. Then there are three further floor levels, taken up with single and double rooms, and living room, a small kitchen and various services. All rooms have a fine view over the Constance Lake.En la planta inferior de este edificio están ubicados: el cuarto de calderas, carbonera, etc. Su planta baja alberga: el vestíbulo principal, portería, oficinas de administración, habitaciones para huéspedes, trasteros, etc.; al mismo nivel se encuentra la capilla, con capacidad para 150 feligreses sentados. La primera planta aloja: los comedores, cocinas, salas de estar, vivienda del director, tres habitaciones dobles, etc. Las plantas segunda, tercera y cuarta contienen: las habitaciones individuales y dobles, una sala de estar, pequeña cocina, etc. Todas las habitaciones gozan de una magnífica vista sobre el lago Constanza.

  12. Toolchain for User-Centered Intelligent Floor Heating Control

    DEFF Research Database (Denmark)

    Agesen, Mads Kronborg; Larsen, Kim Guldstrand; Mikučionis, Marius

    2016-01-01

    temperature is below the user defined target temperature, otherwise it closes for the heating in the room. The disadvantage is that the heat exchange among the rooms, outside weather conditions, weather forecast and other factors are not considered. We propose a novel model-driven approach for intelligent...... floor heating control based on a chain of tools that allow us to gather the sensor readings from the actual hardware and use the state-of-the-art controller synthesis tool UPPAAL Stratego in order to synthesise abstract control strategies that are then executed on the real hardware platform provided...... by the company Seluxit. We have built a scaled demonstrator of the system and the experimental results document a 38% to 52 % increase in user satisfaction, moreover with additional energy savings between 2% to 12%....

  13. Polybrominated diphenyl ethers and “novel” brominated flame retardants in floor and elevated surface house dust from Iraq: Implications for human exposure assessment

    Directory of Open Access Journals (Sweden)

    Layla Salih Al-Omran

    2016-03-01

    Full Text Available Concentrations of polybrominated diphenyl ethers (PBDEs and selected novel brominated flame retardants (NBFRs were measured in indoor dust from the living areas of 18 homes in Basrah, Iraq. This is the first report of contamination of the Iraqi environment with these chemicals. To evaluate the implications for human exposure, samples were collected from both the floor and from elevated surfaces like tables, shelves and chairs. When normalised for the organic carbon content of the dust sample, concentrations in elevated surface dust of BDE-99, BDE-209, pentabromoethylbenzene (PBEB, bis (2-ethylhexyl 3,4,5,6-tetrabromophthalate (BEH-TEBP, and decabromodiphenylethane (DBDPE exceeded significantly (p < 0.05 those in floor dust from the same rooms. This suggests that previous studies that base estimates of adult exposure via dust ingestion on floor dust, may underestimate exposure. Such underestimation is less likely for toddlers who are far more likely to ingest floor dust. Concentrations of PBDEs and NBFRs in indoor dust from Basrah, Iraq are at the lower end of levels reported elsewhere. The PBDE contamination pattern in our samples suggests that use in Iraq of the Deca-BDE formulation, exceeds substantially that of Penta-BDE, but that use of the Octa-BDE formulation has been higher in Iraq than in some other regions. Reassuringly, our estimates of exposure to our target BFRs via dust ingestion for the Iraqi population fall well below the relevant health-based limit values.

  14. Effects of activity inhomogeneities in walls on the external gamma doses in rooms

    Energy Technology Data Exchange (ETDEWEB)

    Feher, I; Andrasi, A; Koblinger, L; Zombori, P; Szabo, P P [Hungarian Academy of Sciences, Budapest. Central Research Inst. for Physics

    1984-01-01

    The effects of activity inhomogeneities in the walls of a room on the free-in-air and spherical phantom doses are investigated. Calculations and measurements are carried out in a room where the ratios of the activity concentrations in the upper layer of the ceiling and floor are as large as 20 and 6, for the Ra and Th chains, respectively.

  15. Excavation damage zone tracer experiment in the floor of the room 415 test tunnel

    International Nuclear Information System (INIS)

    Frost, L.H.; Everitt, R.A.

    1997-03-01

    A 3.5-m-diameter test tunnel was constructed on the 420 Level of AECL's Underground Research Laboratory using a mechanical excavation technique. The orientation of the tunnel was chosen to maximize the stress ratio in the plane perpendicular to the tunnel axis in order to promote and study stress-induced excavation damage. The resulting excavation damage zone (EDZ) is characterized by a distinct breakout notch in both the floor and roof of the tunnel. In the floor of the tunnel, the main flow pathway within the EDZ is within a zone of intense grain-size fracturing (process zone) located at the tip of the breakout notch; virtually no flow occurs outside this region. A tracer experiment was performed within the EDZ in the floor of the tunnel to characterize the solute transport properties (permeability, transport porosity and dispersivity) within the process zone, as well as to develop and demonstrate methods for determining the transport properties within EDZs of underground tunnels. The experiment was performed as a constant head test by continuously injecting a constant concentration of iodide tracer into a region of the process zone, and by monitoring tracer breakthrough from the zone at a distance 1.5 m away. An equivalent-porous-media approach was taken in analysing fluid flow and solute transport through the process zone. Based on mass flux calculations, the hydraulic conductivity and transport porosity of the process zone are estimated to be 7.4 x 10 -7 m/s and 2.7 % respectively. Based on an analytic solution that represents tracer transport within the process zone as one-dimensional advective diffusive transport in a finite homogeneous porous medium, the longitudinal dispersivity and transport porosity of the zone are estimated to be 0.60 m and 3.3 % respectively. The transport porosity values estimated by both the mass flux and analytic calculations compare quite well. (author)

  16. SUSTAINABLE TRAILER FLOORING

    Directory of Open Access Journals (Sweden)

    John Lu

    2009-05-01

    Full Text Available Different trailer flooring materials, including wood-based, aluminum, steel, and synthetic plastic floors, were evaluated in accordance with their durability and sustainability to our natural environment. Wood-based trailer flooring is an eco-friendly product. It is the most sustainable trailer flooring material compared with fossil fuel-intensive steel, aluminum, and plastics. It is renewable and recyclable. Oak, hard maple, and apitong are strong and durable hardwood species that are currently extensively used for trailer flooring. For manufacture, wood-based flooring is higher in energy efficiency and lower in carbon emission than steel, aluminum and plastics. Moreover, wood per se is a natural product that sequesters carbon. Accordingly, using more wood-based trailer flooring is effective to reduce global warming.

  17. An assessment of formaldehyde emissions from laminate flooring manufactured in China.

    Science.gov (United States)

    Pierce, Jennifer S; Abelmann, Anders; Lotter, Jason T; Ruestow, Peter S; Unice, Kenneth M; Beckett, Evan M; Fritz, Heidi A; Bare, Jennifer L; Finley, Brent L

    2016-11-01

    Formaldehyde emissions from two laminate flooring products, labeled as California Air Resources Board (CARB) compliant, were evaluated. Passive 24-hr samples (n = 79) and real-time measurements were collected following installation and removal of the products in two rooms of similar size. Mean formaldehyde concentrations following installation were 0.038 and 0.022 ppm for Products 1 and 2 respectively, and 7 days after flooring removal the concentrations returned to background pre-installation levels. Both products were also evaluated in a small chamber (ASTM D6007) using Deconstructive (de-laminated product) and Non-Deconstructive (intact product) methods. Deconstructive testing showed that Product 1 exceeded the applicable CARB emission standard by 4-fold, while Product 2 was equivalent to the standard. Non-Deconstructive measurements were far below the Deconstructive results and were used to predict 24-hr steady-state room air concentrations. Based on the products that we tested (one of which was found to not be compliant with the CARB standard), the airborne formaldehyde concentrations measured following installation in a real-world setting would not be expected to elicit adverse acute health effects. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Floors: Selection and Maintenance.

    Science.gov (United States)

    Berkeley, Bernard

    Flooring for institutional, commercial, and industrial use is described with regard to its selection, care, and maintenance. The following flooring and subflooring material categories are discussed--(1) resilient floor coverings, (2) carpeting, (3) masonry floors, (4) wood floors, and (5) "formed-in-place floors". The properties, problems,…

  19. StreetTiVo: Using a P2P XML Database System to Manage Multimedia Data in Your Living Room

    NARCIS (Netherlands)

    Zhang, Ying; de Vries, A.P.; Boncz, P.; Hiemstra, Djoerd; Ordelman, Roeland J.F.; Li, Qing; Feng, Ling; Pei, Jian; Wang, Sean X.

    StreetTiVo is a project that aims at bringing research results into the living room; in particular, a mix of current results in the areas of Peer-to-Peer XML Database Management System (P2P XDBMS), advanced multimedia analysis techniques, and advanced information re- trieval techniques. The project

  20. Control room philosophy: Principles of control room design and control room work

    International Nuclear Information System (INIS)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla

    2006-01-01

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages

  1. Study on the main control room design for Hamaoka Unit No.5

    International Nuclear Information System (INIS)

    Tsuruta, Tadakazu; Sakamoto, Minoru; Maruyama, Tohru; Saito, Tadashi

    2000-01-01

    The main control room of nuclear power station is important to operate the power station and to promote public acceptance of nuclear power station. To enhance them, there is an idea of high ceiling control room with a gallery room located in backside middle upper floor. The control room is expected to enhance habitability and to offer visitors the fine view of the control room. In this study, psychological and physiological influence of such a high ceiling control room design on operators was investigated first. And then some human engineering requirements for desirable main control room were identified. A control room (ceiling height: about 5 meters) adequate to the requirements was designed, and finally the validity of the design was verified by means of full mockup model room tests. The results of this study are applied to the main control room design of Hamaoka Nuclear Power Station Unit No.5 (Chubu Electric Power Co., Inc.) (author)

  2. Suppress flashover of GRP fire with water mist inside ISO 9705 Room

    Directory of Open Access Journals (Sweden)

    Qiang Xu

    2011-01-01

    Full Text Available Water mist suppression tests for glass-reinforced polyester (GRP panels were conducted in ISO 9705 room. GRP panels covered part of the room and a wood crib fire was used as fire source to ignite GRP fire. A four-nozzle water mist suppression equipment was used inside test room on the time of flashover. Heat release rate of the combustion inside the room, room temperature, surface temperature of GRP panels, total heat flux to wall, ceiling and floor in specific positions were measured. Gas concentration of O2, CO, and CO2 was also measured in the corner of the room at two different levels. A thermal image video was used to record the suppression procedure inside room. Test results show that the water mist system is efficient in suppressing the flashover of GRP fire and cooling the room within short time.

  3. Pelvic floor muscle function in women with pelvic floor dysfunction

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Dehlendorff, Christian

    2014-01-01

    The objectives of this study were to investigate the level of pelvic floor muscle (PFM) function in women with pelvic floor dysfunction (PFD) referred by gynaecologists and urologists for in-hospital pelvic floor muscle training (PFMT), and to identity associated factors for a low level of PFM...

  4. Adaptive Indoor Positioning Model Based on WLAN-Fingerprinting for Dynamic and Multi-Floor Environments

    Directory of Open Access Journals (Sweden)

    Iyad Husni Alshami

    2017-08-01

    Full Text Available The Global Positioning System demonstrates the significance of Location Based Services but it cannot be used indoors due to the lack of line of sight between satellites and receivers. Indoor Positioning Systems are needed to provide indoor Location Based Services. Wireless LAN fingerprints are one of the best choices for Indoor Positioning Systems because of their low cost, and high accuracy, however they have many drawbacks: creating radio maps is time consuming, the radio maps will become outdated with any environmental change, different mobile devices read the received signal strength (RSS differently, and peoples’ presence in LOS between access points and mobile device affects the RSS. This research proposes a new Adaptive Indoor Positioning System model (called DIPS based on: a dynamic radio map generator, RSS certainty technique and peoples’ presence effect integration for dynamic and multi-floor environments. Dynamic in our context refers to the effects of people and device heterogeneity. DIPS can achieve 98% and 92% positioning accuracy for floor and room positioning, and it achieves 1.2 m for point positioning error. RSS certainty enhanced the positioning accuracy for floor and room for different mobile devices by 11% and 9%. Then by considering the peoples’ presence effect, the error is reduced by 0.2 m. In comparison with other works, DIPS achieves better positioning without extra devices.

  5. Towards room temperature solid state quantum devices at the edge of quantum chaos for long-living quantum states

    International Nuclear Information System (INIS)

    Prati, Enrico

    2015-01-01

    Long living coherent quantum states have been observed in biological systems up to room temperature. Light harvesting in chromophoresis realized by excitonic systems living at the edge of quantum chaos, where energy level distribution becomes semi-Poissonian. On the other hand, artificial materials suffer the loss of coherence of quantum states in quantum information processing, but semiconductor materials are known to exhibit quantum chaotic conditions, so the exploitation of similar conditions are to be considered. The advancements of nanofabrication, together with the control of implantation of individual atoms at nanometric precision, may open the experimental study of such special regime at the edge of the phase transitions for the electronic systems obtained by implanting impurity atoms in a silicon transistor. Here I review the recent advancements made in the field of theoretical description of the light harvesting in biological system in its connection with phase transitions at the few atoms scale and how it would be possible to achieve transition point to quantum chaotic regime. Such mechanism may thus preserve quantum coherent states at room temperature in solid state devices, to be exploited for quantum information processing as well as dissipation-free quantum electronics. (paper)

  6. SUSTAINABLE TRAILER FLOORING

    OpenAIRE

    John Lu; Marc Chorney; Lowell Peterson

    2009-01-01

    Different trailer flooring materials, including wood-based, aluminum, steel, and synthetic plastic floors, were evaluated in accordance with their durability and sustainability to our natural environment. Wood-based trailer flooring is an eco-friendly product. It is the most sustainable trailer flooring material compared with fossil fuel-intensive steel, aluminum, and plastics. It is renewable and recyclable. Oak, hard maple, and apitong are strong and durable hardwood species that are curren...

  7. Creating Engaging Escape Rooms for the Classroom

    Science.gov (United States)

    Nicholson, Scott

    2018-01-01

    Escape rooms are "live-action team-based games where players discover clues, solve puzzles, and accomplish tasks in one or more rooms in order to accomplish a specific goal (usually escaping from the room) in a limited amount of time." Escape Rooms are one type of Escape Game, which are narrative-based challenges that use puzzles, tasks,…

  8. 9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.

    Science.gov (United States)

    2010-01-01

    ... rooms shall be well-lighted and have ceilings and walls of a tile surface, enamel paint, or other water-resistant material. (1) The floors shall be free from cracks or rough surfaces where water or dirt could...

  9. Conventional heat distribution systems and their control for room cooling; Konventionelle Waermeabgabesysteme und deren Regulierung fuer die Raumkuehlung - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, J. [Schnyder-Energie, Energie-Dienstleistungen, Bronschhofen (Switzerland); Feger, D.; Graf, J.; Rusterholtz, R. [Interstaatliche Hochschule fuer Technik Buchs NTB, Buchs (Switzerland); Schoeringhumer, D.; Cenci, D. [Arbonia AG, Arbon (Switzerland); Heule, D. [hps energieconsulting ag, Ingenieurbuero fuer nachhaltige Energie- und Gebaeudetechnik, Kuesnacht (Switzerland)

    2009-12-15

    This final report for the Swiss Federal Office of Energy (SFOE) examines how conventional heat distribution systems such as radiators and floor heating systems can be used for room cooling and the appropriate control requirements. Thermostatic valves used 'in reverse', their functional testing and the results obtained are discussed. Possibilities for their optimisation are examined. The apparatus used for the measurements made on both radiator and floor-heating systems is reported on and the results obtained are presented and discussed. Further, simulations used are looked at and examples of the results obtained for rooms with varying glazed surfaces are presented and discussed.

  10. Evaluation of the room shielding thickness of Hi-Art tomotherapy system

    International Nuclear Information System (INIS)

    Liu Haikuan; Wu Jinhai; Gu Naigu; Gao Yiming; Wang Li; Huang Weiqin; Wang Fengxian

    2010-01-01

    In this paper, we calculate and evaluate the room shielding thickness of a Hi-Art tomotherapy system, which is a new type of radiotherapy facility. Due to the self-shielding of the accelerator,only scattered beam and beam leakage were considered in calculating the room shielding thickness. The radiation field of the tomotherapy system was used as the basic data to calculate the shielding thickness of every 15 degree solid angle. The maximum shielding thickness required of each shielding wall was at the position with the angle of 15 degree, and the calculated shielding thickness were 1023, 975, 917, 1460, 1147 and 1189 mm for the east wall,south wall,west wall, north wall, the roof and the floor,respectively. According to the calculation results, all shielding walls, ceiling and floor could meet the requirement of the radiation protection, but the north wall thickness of 1200 mm was a little thinner. (authors)

  11. Reduced energy reqirement for air conditioning by using air diffusion with air flow from floor to ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Dittes, W; Mangelsdorf, R; Detzer, R; Jungbaeck, E; Fitzner, K; Radtke, W; Soethout, F

    1982-02-01

    The condition of the air in the occupied zone in airconditioned rooms is influenced by the mixing of supply air with room air. When supplying air from the ceiling there is a mixing all over the room, when supplying from the floor or from desks there is a mixing region only in the lower area. Above this their is warm air from which the return air is drawn. For air supply from below the cooling load can be decreased. In combination with the possible enthalpy difference between room air and supply air this decrease of the cooling load influences the necessary air rate. The interdependence of various air conditioning systems and various air temperatures is shown with a computer program. The load factor for various air distribution system at various cooling loads have been measured in a room of (8 x 5)m/sup 2/ x 3m. Experiments in a smaller model room (scale 1:3) showed how the heat was transported from the mixing region to the stratification region. The theoretically gained influence of the supply air jets of the height of the mixing region and on the load rate could be verified by the experiments. For the design of the fresh air rate, experience has been gained by measurements with tracegas (N/sub 2/O) in a third room. In comparing calculations the annual energy consumption has been computed for a building assuming various air conditioning systems and typical operation data. From experience with the existing systems the conclusions have been drawn how air distribution from floor to ceiling can be installed and operated.

  12. Calculation of Appropriate Minimum Size of Isolation Rooms based on Questionnaire Survey of Experts and Analysis on Conditions of Isolation Room Use

    Science.gov (United States)

    Won, An-Na; Song, Hae-Eun; Yang, Young-Kwon; Park, Jin-Chul; Hwang, Jung-Ha

    2017-07-01

    After the outbreak of the MERS (Middle East Respiratory Syndrome) epidemic, issues were raised regarding response capabilities of medical institutions, including the lack of isolation rooms at hospitals. Since then, the government of Korea has been revising regulations to enforce medical laws in order to expand the operation of isolation rooms and to strengthen standards regarding their mandatory installation at hospitals. Among general and tertiary hospitals in Korea, a total of 159 are estimated to be required to install isolation rooms to meet minimum standards. For the purpose of contributing to hospital construction plans in the future, this study conducted a questionnaire survey of experts and analysed the environment and devices necessary in isolation rooms, to determine their appropriate minimum size to treat patients. The result of the analysis is as follows: First, isolation rooms at hospitals are required to have a minimum 3,300mm minor axis and a minimum 5,000mm major axis for the isolation room itself, and a minimum 1,800mm minor axis for the antechamber where personal protective equipment is donned and removed. Second, the 15 ㎡-or-larger standard for the floor area of isolation rooms will have to be reviewed and standards for the minimum width of isolation rooms will have to be established.

  13. The Effect of Epoxy Molding Compound Floor Life to Reliability Performance and mold ability for QFN Package

    Science.gov (United States)

    Peanpunga, Udom; Ugsornrat, Kessararat; Thorlor, Panakamol; Sumithpibul, Chalermsak

    2017-09-01

    This research studied about an epoxy molding compound (EMC) floor life to reliability performance of integrated circuit (IC) package. Molding is the process for protecting the die of IC package form mechanical and chemical reaction from external environment by shaping EMC. From normal manufacturing process, the EMC is stored in the frozen at 5oC and left at around room temperature for aging time or floor life before molding process. The EMC floor life effect to its properties and reliability performance of IC package. Therefore, this work interested in varied the floor life of EMC before molding process to analyze properties of EMC such as spiral flow length, gelation time, and viscosity. In experiment, the floor life of EMC was varied to check the effect of its property to reliability performance. The EMC floor life were varied from 0 hours to 60 hours with a step of 12 hours and observed wire sweep, incomplete EMC, and delamination inside the packages for 3x3, 5x5 and 8x8 mm2 of QFN packages. The evaluation showed about clearly effect of EMC floor life to IC packaging reliability. EMC floor life is not any concern for EMC property, moldabilty, and reliability from 0 hours to 48 hours for molding process of 3x3,5x5 and 8x8 mm2 QFN packaging manufacturing

  14. Radioactivity of radon and its short-lived decay products in room air, 2

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Katoh, Takao

    1983-01-01

    In the reactor room of the Kyoto University Research Reactor Institute, the measurements of radon (Rn) and its short-lived decay products (Rn-Dts) were carried out under ventilated and non-ventilated conditions. The indoor activities were equal to outdoor ones under ventilated condition and those activities increased till about 10 times of outdoors under non-ventilated condition. We attempted to explain these results on a basis of a simple model. The calculations were performed taking into account: (1) supply of Rn and Rn-Dts from outdoor, (2) the emanation rate of Rn from the wall materials of building, (3) the removal rate of Rn-Dts by ventilation and wall deposition, and (4) the attachment rate of unattached atom to aerosols. In addition, natural ventilation were considered during periods without artificial ventilation. (author)

  15. Human-Like Room Segmentation for Domestic Cleaning Robots

    Directory of Open Access Journals (Sweden)

    David Fleer

    2017-11-01

    Full Text Available Autonomous mobile robots have recently become a popular solution for automating cleaning tasks. In one application, the robot cleans a floor space by traversing and covering it completely. While fulfilling its task, such a robot may create a map of its surroundings. For domestic indoor environments, these maps often consist of rooms connected by passageways. Segmenting the map into these rooms has several uses, such as hierarchical planning of cleaning runs by the robot, or the definition of cleaning plans by the user. Especially in the latter application, the robot-generated room segmentation should match the human understanding of rooms. Here, we present a novel method that solves this problem for the graph of a topo-metric map: first, a classifier identifies those graph edges that cross a border between rooms. This classifier utilizes data from multiple robot sensors, such as obstacle measurements and camera images. Next, we attempt to segment the map at these room–border edges using graph clustering. By training the classifier on user-annotated data, this produces a human-like room segmentation. We optimize and test our method on numerous realistic maps generated by our cleaning-robot prototype and its simulated version. Overall, we find that our method produces more human-like room segmentations compared to mere graph clustering. However, unusual room borders that differ from the training data remain a challenge.

  16. 27 February 2012- Thai Minister of Science and Technology P. Suraswadi with International Relations Adviser E. Tsesmelis and CMS Collaboration Former Deputy Spokesperson A. De Roeck signing the guest book in the 6th floor conference room, building 60 and visiting CMS underground experimental area at LHC Point 5.

    CERN Multimedia

    Maximilien Brice

    2012-01-01

    27 February 2012- Thai Minister of Science and Technology P. Suraswadi with International Relations Adviser E. Tsesmelis and CMS Collaboration Former Deputy Spokesperson A. De Roeck signing the guest book in the 6th floor conference room, building 60 and visiting CMS underground experimental area at LHC Point 5.

  17. Potential human exposure to halogenated flame-retardants in elevated surface dust and floor dust in an academic environment

    International Nuclear Information System (INIS)

    Allgood, Jaime M.; Jimah, Tamara; McClaskey, Carolyn M.; La Guardia, Mark J.; Hammel, Stephanie C.; Zeineddine, Maryam M.; Tang, Ian W.; Runnerstrom, Miryha G.; Ogunseitan, Oladele A.

    2017-01-01

    Most households and workplaces all over the world possess furnishings and electronics, all of which contain potentially toxic flame retardant chemicals to prevent fire hazards. Indoor dust is a recognized repository of these types of chemicals including polybrominated diphenyl ethers (PBDEs) and non-polybrominated diphenyl ethers (non-PBDEs). However, no previous U.S. studies have differentiated concentrations from elevated surface dust (ESD) and floor dust (FD) within and across microenvironments. We address this information gap by measuring twenty-two flame-retardant chemicals in dust on elevated surfaces (ESD; n=10) and floors (FD; n=10) from rooms on a California campus that contain various concentrations of electronic products. We hypothesized a difference in chemical concentrations in ESD and FD. Secondarily, we examined whether or not this difference persisted: (a) across the studied microenvironments and (b) in rooms with various concentrations of electronics. A Wilcoxon signed-rank test demonstrated that the ESD was statistically significantly higher than FD for BDE-47 (p=0.01), BDE-99 (p=0.01), BDE-100 (p=0.01), BDE-153 (p=0.02), BDE-154 (p=0.02), and 3 non-PBDEs including EH-TBB (p=0.02), BEH-TEBP (p=0.05), and TDCIPP (p=0.03). These results suggest different levels and kinds of exposures to flame-retardant chemicals for individuals spending time in the sampled locations depending on the position of accumulated dust. Therefore, further research is needed to estimate human exposure to flame retardant chemicals based on how much time and where in the room individuals spend their time. Such sub-location estimates will likely differ from assessments that assume continuous unidimensional exposure, with implications for improved understanding of potential health impacts of flame retardant chemicals. - Highlights: • Brominated flame retardants used in electronic products accumulate in room dust • Various chemical moieties of flame retardants leach

  18. Potential human exposure to halogenated flame-retardants in elevated surface dust and floor dust in an academic environment

    Energy Technology Data Exchange (ETDEWEB)

    Allgood, Jaime M.; Jimah, Tamara [Department of Population Health & Disease Prevention, Program in Public Health, University of California, Irvine, CA 92697-3957 (United States); McClaskey, Carolyn M. [Department of Cognitive Sciences, School of Social Sciences, University of California, Irvine, CA 92697-5100 (United States); La Guardia, Mark J. [Department of Aquatic Health Sciences, Virginia Institute of Marine Science, College of William and Mary, Gloucester Point, VA 23062 (United States); Hammel, Stephanie C.; Zeineddine, Maryam M.; Tang, Ian W.; Runnerstrom, Miryha G. [Department of Population Health & Disease Prevention, Program in Public Health, University of California, Irvine, CA 92697-3957 (United States); Ogunseitan, Oladele A., E-mail: Oladele.Ogunseitan@uci.edu [Department of Population Health & Disease Prevention, Program in Public Health, University of California, Irvine, CA 92697-3957 (United States)

    2017-02-15

    Most households and workplaces all over the world possess furnishings and electronics, all of which contain potentially toxic flame retardant chemicals to prevent fire hazards. Indoor dust is a recognized repository of these types of chemicals including polybrominated diphenyl ethers (PBDEs) and non-polybrominated diphenyl ethers (non-PBDEs). However, no previous U.S. studies have differentiated concentrations from elevated surface dust (ESD) and floor dust (FD) within and across microenvironments. We address this information gap by measuring twenty-two flame-retardant chemicals in dust on elevated surfaces (ESD; n=10) and floors (FD; n=10) from rooms on a California campus that contain various concentrations of electronic products. We hypothesized a difference in chemical concentrations in ESD and FD. Secondarily, we examined whether or not this difference persisted: (a) across the studied microenvironments and (b) in rooms with various concentrations of electronics. A Wilcoxon signed-rank test demonstrated that the ESD was statistically significantly higher than FD for BDE-47 (p=0.01), BDE-99 (p=0.01), BDE-100 (p=0.01), BDE-153 (p=0.02), BDE-154 (p=0.02), and 3 non-PBDEs including EH-TBB (p=0.02), BEH-TEBP (p=0.05), and TDCIPP (p=0.03). These results suggest different levels and kinds of exposures to flame-retardant chemicals for individuals spending time in the sampled locations depending on the position of accumulated dust. Therefore, further research is needed to estimate human exposure to flame retardant chemicals based on how much time and where in the room individuals spend their time. Such sub-location estimates will likely differ from assessments that assume continuous unidimensional exposure, with implications for improved understanding of potential health impacts of flame retardant chemicals. - Highlights: • Brominated flame retardants used in electronic products accumulate in room dust • Various chemical moieties of flame retardants leach

  19. Solving decontaminable flooring problems

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Pennsylvania Power and Light wanted to cover deteriorating concrete in unit 2 of its Susquehanna BWR with a smooth, durable, decontaminable coating. Traditionally, floors in the plant had been coated with epoxy paint, but many of these floors suffered delamination, and failed in three to five years. Painting with epoxy would also interrupt operations for as much as three days while the floor dried, yet critical instruments in some areas had to be monitored at least once per shift. In addition, conventional floor surface preparation produced dust and vibration around sensitive equipment. The solution was a dustless scabbling system for surface preparation, followed by the installation of a high-strength acrylic industrial floor known as Silakal. The work was carried out by Pentek. Silikal bonds to the underlying concrete, so that delamination of the floor will not occur even under severe traffic conditions. Another advantage of this type of flooring is that it cures in one hour, so floor resurfacing has only minimal impact on plant operations. (author)

  20. Assessment of slip resistance under footwear materials, tread designs, floor contamination, and floor inclination conditions.

    Science.gov (United States)

    Li, Kai Way; Chen, Chih-Yong; Chen, Ching Chung; Liu, Liwen

    2012-01-01

    Slip and fall incidences are common in our daily lives. They are not only important environmental safety issues but also important occupational safety and health problems. The purpose of this study was to use the Brungraber Mark II to measure the friction so as to investigate the effects of the shoe sole, surface condition and the inclined angle of the floor and their interactions on friction coefficient. The results of the study showed the effects of all the main factors and their interactions were significant (p<0.001). Engineering designs & ergonomic interventions in slip & fall prevention should take these factors in full consideration.

  1. Introductory guide to floors and flooring

    CSIR Research Space (South Africa)

    Billingham, PA

    1977-01-01

    Full Text Available not make use of the warming and cooling effects of direct contact with the ground. Indeed the precautions that are necessary to protect such floors against damp and decay may actually reduce the comfort levels within a house. This is because there is a... with resultant discomfort and extra heating costs. Today, in South Africa, most modern homesareof singlestorey con- struction with aconcrete floor slab in direct contact with theground which once again makes its full contribution to the comfort and structural...

  2. Room source management decontamination in Uruguay

    International Nuclear Information System (INIS)

    Blanco, D.; Montanez, Osvaldo

    1998-01-01

    A surface,work materials and tools contamination it produced for Ra-226 sources management in des use in Uruguayan radioactive waste and sources management and storage room specifically in the Uruguay Republic University in Nuclear Search Center. A surface contamination direct was performed measurement with Eberline alpha particles Contamat FHT 111M with 42 496/30 sounder. It found greater and least contamination grade in all cement floor as well as in tables where was managed with Ra-226 sources. A value measured surface contamination can see in the Room scheme with more 200 Bq/cm in extension small places. A segregation between work materials and tools considerate d free contamination was realized. The contaminated objects was separated for a future treatment. A proceeding followed in the decontamination was inhale, abrasion,sweep essays in different representative zones, obtain decontamination factors and residual activity

  3. Analysis of an Attached Sunspace with a Thermal Inertia Floor

    Directory of Open Access Journals (Sweden)

    María José Suárez López

    2018-05-01

    Full Text Available An attached sunspace is a partially or fully glazed enclosure, usually located on the first floor, facing south (in the Northern Hemisphere and adjacent to a conditioned room. Because of the length and orientation of the glazed area, the temperature in the sunspace is usually higher than outside the building. As a Trombe–Mitchel wall, the sunspace has a considerable mass that accumulates thermal energy, but in this case the thermal mass is located in the floor. This capacity to accumulate thermal energy confers the attached sunspace features beyond passive insulation. The sunspace studied in this paper is part of an experimental building located in the North of Spain that was built in the frame of the so-called ARFRISOL project. It consists of a south-facing glazed exterior wall with both clear glass and semi-transparent photovoltaic panels, an intermediate space with a thick layer of sand over a concrete floor, and a partially glazed interior wall. In this paper, a three-dimensional computational model has been implemented to analyse the thermal behaviour inside the sunspace. This analysis takes into account, among other factors, the effects of sun position, incident solar irradiation and temperature both inside and outside.

  4. Spray washing, absorbent corn starch powder and dry time to reduce bacterial numbers on soiled boiler transport cage flooring

    Science.gov (United States)

    Most broilers in the U.S. are transported live to slaughter facilities in cages with fiberglass floors. Cages are often used repeatedly without washing and fecal matter deposited on the floor surface can transfer Campylobacter from one flock to another. Drying feces out between uses is an effectiv...

  5. Convection From a Slender Cylender in a Ventilated Room

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Sandberg, M.

    1990-01-01

    with measurements in the boundary layer flow around a heated vertical slender cylinder in a full-scale test room with displacement ventilation. Both velocity and temperature profiles in the boundary layer flow were recorded. The room was ventilated by a low velocity diffuser, standing on the floor, from which air......The equations, based on an integral formulation, for turbulent natural boundary layer flow are solved in both the constant temperature case and in the constant heat flux case. Solutions are found. for convection along both flat plates and cylinders. Theoretical predictions are compared...... with a negative buoyancy was supplied. The vertical distribution of both temperature and contamination in the room was measured as a function of the heat load and the air flow rate. The contaminant distribution showed a clear stratification between clean and contaminated air, while the temperature was increasing...

  6. Effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction

    Directory of Open Access Journals (Sweden)

    Shi-Qiong Li

    2017-04-01

    Full Text Available Objective: To explore the effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction and on the sexual life quality. Methods: A total of 286 puerpera with pelvic floor dysfunction who were admitted in our hospital from May, 2014 to May, 2015 42 d after delivery were included in the study, and randomized into the treatment group and the control group with 143 cases in each group. After guidance, the puerpera in the control group were given pelvic floor muscle training by themselves at home. On this basis, the puerpera in the treatment group were treated by the pelvic floor rehabilitation apparatus. The puerpera in the two groups were treated for 4 weeks. The pelvic floor function before treatment, 6 months and 1 year after delivery was detected. The color Doppler ultrasound apparatus was used to detect BSD, PUVA, UVJ-M, and BND 3 months after delivery. Results: BND, PUVA-R, PUVA-S, and UVJ-M 3 months after delivery in the treatment groups were significantly lower than those in the control group, while BSD-S was significantly higher than that in the control group. The improvement of type I and II muscle fiber fatigue (%, POP-Q degree, AP indication point (cm, and vaginal dynamic pressure (cmH2O was significantly superior to that in the control group. The comparison of pelvic floor muscle strength classification before treatment between the two groups was not statistically significant. After treatment, the pelvic floor muscle in the two groups was significantly strengthened, and the proportion of V grade patients was significantly increased when compared with before treatment. Conclusions: The postpartum early pelvic floor rehabilitation technique can effectively enhance the pelvic floor function, and prevent the postpartum pelvic floor dysfunction, with an accurate efficacy; therefore, it deserves to be widely recommended in the clinic.

  7. The Association between Residence Floor Level and Cardiovascular Disease: The Health and Environment in Oslo Study.

    Science.gov (United States)

    Rohde, Mads K; Aamodt, Geir

    2016-01-01

    Background. Increasingly more people live in tall buildings and on higher floor levels. Factors relating to floor level may protect against or cause cardiovascular disease (CVD). Only one previous study has investigated the association between floor level and CVD. Methods. We studied associations between floor of bedroom and self-reported history of stroke, venous thromboembolism (VTE), and intermittent claudication (IC) among 12.525 inhabitants in Oslo, Norway. We fitted multivariate logistic regression models and adjusted for sociodemographic variables, socioeconomic status (SES), and health behaviors. Additionally, we investigated block apartment residents ( N = 5.374) separately. Results. Trend analyses showed that disease prevalence increased by floor level, for all three outcomes. When we investigated block apartment residents alone, the trends disappeared, but one association remained: higher odds of VTE history on 6th floor or higher, compared to basement and 1st floor (OR: 1.504; 95% CI: 1.007-2.247). Conclusion. Floor level is positively associated with CVD, in Oslo. The best-supported explanation may be residual confounding by building height and SES. Another explanation, about the impact of atmospheric electricity, is also presented. The results underline a need to better understand the associations between residence floor level and CVD and multistory housing and CVD.

  8. Effect of floor type (dirt or concrete on litter quality, house environmental conditions, and performance of broilers

    Directory of Open Access Journals (Sweden)

    VMN Abreu

    2011-06-01

    Full Text Available This study was conducted with the objective of evaluating the use of concrete or hard-packed dirt floor in broiler houses. This experiment was carried out in two different phases. The following performance parameters were studied: live weight, feed intake, feed conversion ratio, and mortality. Litter moisture, pH and temperature were measured. Litter residual contamination after cleaning and disinfection was also evaluated. A dry bulb thermometer, a wet bulb thermometer, and a black bulb thermometer were placed inside each broiler house at bird height and outside the broiler house for data collection. Environmental data were collected at 3h intervals from 00:00 to 24:00 hours during weeks 4, 5, and 6 of the grow-out. Based on the collected data, air relative humidity (RH was determined, after which wet bulb globe temperature (WBGT and Radiant Heat Load (RHL were calculated. There were no differences in live performance parameters. However, total mortality and sudden death were higher in birds raised on dirt floor. On days 0, 14 and 35, litter pH was higher in the dirt floor as compared to the concrete floor, but at the end of the grow-out, this difference disappeared. There was a cubic effect of bird age on litter moisture, which increased up to day 28, and then stabilized or decreased. Litter coliform contamination was higher at the end of the grow-out as compared to that found at housing, but it was not influenced by floor type. The general thermal comfort of broiler raised on dirt floor was similar to that of broilers raised on concrete floor.

  9. Decontamination of floor surfaces

    International Nuclear Information System (INIS)

    Smirous, F.

    1983-01-01

    Requirements are presented put on the surfaces of floors of radiochemical workplaces. The mechanism is described of retaining the contaminant in the surface of the flooring, ways of reducing the hazards of floor surface contamination, decontamination techniques and used decontamination agents. (J.P.)

  10. Resident's Floor Level Preference in High-Rise Residential Buildings in China: A Case Study of Shijiazhuang City,Hebei Province

    Institute of Scientific and Technical Information of China (English)

    Sun Pingjun; Wang Ying; Pang Ruiqiu; Song Xinyan

    2016-01-01

    With the constant advance of global urbanization and aggravation of urban construction land scarcity,high-rise residential buildings have become one of the main carriers of urban residential function on account of both land saving and large housing requirement.However,relevant studies on consumers' floor selection preference in high-rise residential buildings,regarding what inherent and regular features and causes it has,are still insufficient,despite that related issues have important practical significance for real estate developers and designers' decision making in terms of dwelling size ratio,floor area,indoor layout,and so on.This study,based on systematic examination of existing domestic and international researches,seeks to make empirical tests and generalization on the above issues from the aspect of"utility function" (safety,comfortableness,accessibility and economic efficiency) of the living environment that impacted by different floor levels,and floor selection features regarding consumers' social and family structure attributes,as well as the intrinsic correlation between them.The results show the existence of floor level preference in high-rise residential buildings.Its essence is a personalized characterization of consumers' social and family structures' attributes in selecting the "utility function" of the living environment,as the preference value differs under various attributes including gender,age,income,family members and others.

  11. Velocity Distribution in a Room Ventilated by Displacement Ventilation and Wall-Mounted Air Terminal Devices

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    2000-01-01

    The article describes experiments with wall-mounted air terminal devices. The airflow from an air terminal device influences the occupants' thermal comfort and, therefore, it is important to develop an expression for this flow in the occupied zone. The velocity at the floor is influenced...... by the flow rate to the room, the temperature difference and the type of diffuser. The flow is stratified at Archimedes numbers larger than four. The article gives expressions for the velocity distribution close to the floor. It is shown that openings between obstacles placed directly on the floor generate...... a flow similar to the air movement in front of a diffuser, and expressions for the velocity distribution in that situation are also given in the article....

  12. Flooring-systems and their interaction with usage of the floor

    DEFF Research Database (Denmark)

    Pedersen, Lars; Frier, Christian; Andersen, Lars Vabbersgaard

    2017-01-01

    Some flooring-system designs might be sensitive to their vibrational performance, as there might be the risk that serviceability-limit-state problems may be encountered. For evaluating the vibrational performance of the flooring-system at the design stage, decisions need to be made by the enginee...

  13. Control room philosophy: Principles of control room design and control room work; Kontrollrumsfilosofi: Principer foer kontrollrumsutformning och kontrollrumsarbete

    Energy Technology Data Exchange (ETDEWEB)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla [Scandpower Risk Management AB, Uppsala (Sweden)

    2006-01-15

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages.

  14. How Clean Are Hotel Rooms? Part I: Visual Observations vs. Microbiological Contamination.

    Science.gov (United States)

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Current evidence of hotel room cleanliness is based on observation rather than empirically based microbial assessment. The purpose of the study described here was to determine if observation provides an accurate indicator of cleanliness. Results demonstrated that visual assessment did not accurately predict microbial contamination. Although testing standards have not yet been established for hotel rooms and will be evaluated in Part II of the authors' study, potential microbial hazards included the sponge and mop (housekeeping cart), toilet, bathroom floor, bathroom sink, and light switch. Hotel managers should increase cleaning in key areas to reduce guest exposure to harmful bacteria.

  15. Fast and Living Ring-Opening Polymerization of α-Amino Acid N-Carboxyanhydrides Triggered by an "Alliance" of Primary and Secondary Amines at Room Temperature

    KAUST Repository

    Zhao, Wei; Gnanou, Yves; Hadjichristidis, Nikolaos

    2015-01-01

    A novel highly efficient strategy, based on an "alliance" of primary and secondary amine initiators, was successfully developed allowing the fast and living ring-opening polymerization (ROP) of α-amino acid N-carboxyanhydrides (NCAs) at room temperature. (Chemical Equation Presented). © 2015 American Chemical Society.

  16. Fast and Living Ring-Opening Polymerization of α-Amino Acid N-Carboxyanhydrides Triggered by an "Alliance" of Primary and Secondary Amines at Room Temperature

    KAUST Repository

    Zhao, Wei

    2015-04-13

    A novel highly efficient strategy, based on an "alliance" of primary and secondary amine initiators, was successfully developed allowing the fast and living ring-opening polymerization (ROP) of α-amino acid N-carboxyanhydrides (NCAs) at room temperature. (Chemical Equation Presented). © 2015 American Chemical Society.

  17. Supporting shop floor intelligence

    DEFF Research Database (Denmark)

    Carstensen, Peter; Schmidt, Kjeld; Wiil, Uffe Kock

    1999-01-01

    Many manufacturing enterprises are now trying to introduce various forms of flexible work organizations on the shop floor. However, existing computer-based production planning and control systems pose severe obstacles for autonomous working groups and other kinds of shop floor control to become r......-to-day production planning by supporting intelligent and responsible workers in their situated coordination activities on the shop floor....

  18. Predictive Control of Hydronic Floor Heating Systems using Neural Networks and Genetic Algorithms

    DEFF Research Database (Denmark)

    Vinther, Kasper; Green, Torben; Østergaard, Søren

    2017-01-01

    This paper presents the use a neural network and a micro genetic algorithm to optimize future set-points in existing hydronic floor heating systems for improved energy efficiency. The neural network can be trained to predict the impact of changes in set-points on future room temperatures. Additio...... space is not guaranteed. Evaluation of the performance of multiple neural networks is performed, using different levels of information, and optimization results are presented on a detailed house simulation model....

  19. Predicting residential exposure to phthalate plasticizer emitted from vinyl flooring: a mechanistic analysis.

    Science.gov (United States)

    Xu, Ying; Hubal, Elaine A Cohen; Clausen, Per A; Little, John C

    2009-04-01

    A two-room model is developed to estimate the emission rate of di-2-ethylhexyl phthalate (DEHP) from vinyl flooring and the evolving gas-phase and adsorbed surface concentrations in a realistic indoor environment. Because the DEHP emission rate measured in a test chamber may be quite different from the emission rate from the same material in the indoor environment the model provides a convenient means to predict emissions and transport in a more realistic setting. Adsorption isotherms for phthalates and plasticizers on interior surfaces, such as carpet, wood, dust, and human skin, are derived from previous field and laboratory studies. Log-linear relationships between equilibrium parameters and chemical vapor pressure are obtained. The predicted indoor air DEHP concentration at steady state is 0.15 microg/m3. Room 1 reaches steady state within about one year, while the adjacent room reaches steady state about three months later. Ventilation rate has a strong influence on DEHP emission rate while total suspended particle concentration has a substantial impact on gas-phase concentration. Exposure to DEHP via inhalation, dermal absorption, and oral ingestion of dust is evaluated. The model clarifies the mechanisms that govern the release of DEHP from vinyl flooring and the subsequent interactions with interior surfaces, airborne particles, dust, and human skin. Although further model development, parameter identification, and model validation are needed, our preliminary model provides a mechanistic framework that elucidates exposure pathways for phthalate plasticizers, and can most likely be adapted to predict emissions and transport of other semivolatile organic compounds, such as brominated flame retardants and biocides, in a residential environment.

  20. Resident’s Floor Level Preference in High-Rise Residential Buildings in China:A Case Study of Shijiazhuang City,Hebei Province

    Institute of Scientific and Technical Information of China (English)

    Sun; Pingjun; Wang; Ying; Pang; Ruiqiu; Song; Xinyan

    2016-01-01

    With the constant advance of global urbanization and aggravation of urban construction land scarcity,high-rise residential buildings have become one of the main carriers of urban residential function on account of both land saving and large housing requirement.However,relevant studies on consumers’ floor selection preference in high-rise residential buildings,regarding what inherent and regular features and causes it has,are still insufficient,despite that related issues have important practical significance for real estate developers and designers’ decision making in terms of dwelling size ratio,floor area,indoor layout,and so on.This study,based on systematic examination of existing domestic and international researches,seeks to make empirical tests and generalization on the above issues from the aspect of "utility function"(safety,comfortableness,accessibility and economic efficiency) of the living environment that impacted by different floor levels,and floor selection features regarding consumers’ social and family structure attributes,as well as the intrinsic correlation between them.The results show the existence of floor level preference in high-rise residential buildings.Its essence is a personalized characterization of consumers’ social and family structures’ attributes in selecting the "utility function" of the living environment,as the preference value differs under various attributes including gender,age,income,family members and others.

  1. When the tendon autograft is dropped accidently on the floor: A study about bacterial contamination and antiseptic efficacy.

    Science.gov (United States)

    Barbier, O; Danis, J; Versier, G; Ollat, D

    2015-10-01

    Inadvertent contamination of the autograft can occur during anterior cruciate ligament (ACL) reconstruction if the autograft is dropped on the floor during surgery. A study was undertaken to determine the incidence of contamination when a graft is dropped on the operating room floor and the efficacy of antimicrobial solutions to decontaminate it. Samples from 25 patients undergoing ACL reconstruction with a hamstring tendon were sectioned and dropped onto the floor. Cultures were taken after immersion in antiseptic solutions (a chlorhexidine gluconate solution (group 1), a povidone-iodine solution (group 2), and a sodium hypochlorite solution (group 3)). A fourth piece (group 0) was cultured without being exposed to any solution. Cultures of a floor swab were taken at the same time. The floor swab cultures were positive in 96% of cases. The rate of contamination was 40% in group 0, 8% in group 1, 4% in group 2, and 16% in group 3. There was a significant difference between groups 1 and 2 and group 0 (p<0.05) but not between groups 3 and 0. Immersing a graft dropped on the floor during surgery in a chlorhexidine gluconate solution or povidone-iodine solution significantly reduces contamination of the graft. Soaking of the hamstring autograft in one of these solutions is recommended in the case of inadvertent contamination. Laboratory investigation (level 2). Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Influence of a protocol of Pilates exercises on the contractility of the pelvic floor muscles of non-institutionalized elderly persons

    OpenAIRE

    Souza, Ligia Muniz de; Pegorare, Ana Beatriz Gomes de Souza; Christofoletti, Gustavo; Barbosa, Suzi Rosa Miziara

    2017-01-01

    Abstract Objective: To investigate the influence of a protocol of Pilates exercises on the functionality and contractility of the pelvic floor muscles (PFM) of older women living in the city of Campo Grande, Mato Grosso, Brazil. Method: Ten women (median age of 63.4±4.5 years) with little or no pelvic floor dysfunction were subjected to 24 sessions of Pilates exercises lasting one hour each, for 12 weeks. The pressure of the pelvic floor muscles (PFM) was assessed using a perineometer (cmH2...

  3. Detailed measurements and modelling of thermo active components using a room size test facility

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Svendsen, Svend

    2005-01-01

    measurements in an office sized test facility with thermo active ceiling and floor as well as modelling of similar conditions in a computer program designed for analysis of building integrated heating and cooling systems. A method for characterizing the cooling capacity of thermo active components is described...... typically within 1-2K of the measured results. The simulation model, whose room model splits up the radiative and convective heat transfer between room and surfaces, can also be used to predict the dynamical conditions, where especially the temperature rise during the day is important for designing...

  4. 17 CFR 3.11 - Registration of floor brokers and floor traders.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Registration of floor brokers and floor traders. 3.11 Section 3.11 Commodity and Securities Exchanges COMMODITY FUTURES TRADING... a contract market or registered as a derivatives transaction execution facility by the Commission...

  5. Recent Development in the ATLAS Control Room

    CERN Document Server

    Armen Vartapetian

    Only recently the name ATLAS Control Room (ACR) was more associated with the building at Point 1 (SCX1) than with the real thing. But just within the last several months, with the installation of the ACR hardware, that perception has changed significantly. The recently furnished ATLAS control room. But first of all, if you are not familiar with the ATLAS experimental site and are interested in visiting the ATLAS control room to see the place that in the near future will become the brain of the detector operations, it is quite easy to do so. You don't even need safety helmet or shoes! The ACR is located on the ground floor of a not so typical, glass-covered building in Point 1. The building number on the CERN map is 3162, or SCX1 as we call it. It is also easy to recognize that building by its shiny appearance within the cluster of Point 1 buildings if you are driving from Geneva. Final design and prototyping of the ACR hardware started at the beginning of 2006. Evaluation of the chosen hardware confi...

  6. Timbral aspects of reproduced sound in small rooms. I

    DEFF Research Database (Denmark)

    Bech, Søren

    1995-01-01

    , has been simulated using an electroacoustic setup. The model included the direct sound, 17 individual reflections, and the reverberant field. The threshold of detection and just-noticeable differences for an increase in level were measured for individual reflections using eight subjects for noise......This paper reports some of the influences of individual reflections on the timbre of reproduced sound. A single loudspeaker with frequency-independent directivity characteristics, positioned in a listening room of normal size with frequency-independent absorption coefficients of the room surfaces...... and speech. The results have shown that the first-order floor and ceiling reflections are likely to individually contribute to the timbre of reproduced speech. For a noise signal, additional reflections from the left sidewall will contribute individually. The level of the reverberant field has been found...

  7. Dry sand as a specialized layer to improve the acoustic insulation between rooms one above another

    Directory of Open Access Journals (Sweden)

    Díaz, C.

    2013-09-01

    Full Text Available This work presents and analyses the experimental field results of the sound insulation from airborne and impact noise of the horizontal separating elements commonly used in the past, in which a uniform layer of sand was placed on top of the floor construction to serve as a base for the ceramic tiling. The results of the acoustic measurements show that when there is an intermediate layer of sand in the horizontal separating element between rooms, the sound insulation is greater than would be obtained with other construction systems with equal mass per unit area, where the floor is joined rigidly to the floor construction. The effect on the sound insulation between the rooms produced by this layer of sand placed between the floor construction and the tiling is that of a cushioning layer, and demonstrates that this type of structure acts as a floating floor.En este trabajo se exponen y se analizan los resultados experimentales in situ del aislamiento acústico a ruido aéreo y a ruido de impactos de elementos de separación horizontales, habituales hace años, en los que sobre el forjado se coloca una capa uniforme de arena que sirve de asiento al suelo cerámico. Los resultados de las mediciones acústicas muestran que, cuando en el elemento de separación horizontal entre los recintos hay una capa intermedia de arena, el aislamiento acústico es mejor que el que se obtendría con otros sistemas constructivos de igual masa por unidad de superficie, con el suelo unido rígidamente al forjado. El efecto de la capa de arena colocada entre el forjado y el suelo, en el aislamiento acústico entre los recintos, es el de una capa amortiguadora, que hace que este tipo de suelo pueda considerarse como flotante.

  8. Floor cooler for floor trough of a nuclear reactor

    International Nuclear Information System (INIS)

    Friedrich, H.J.

    1985-01-01

    Cooling pipes are situated below the floor trough of a BWR, which are connected to the annular distribution or collection pipes. The distribution and collection pipes are connected by parallel hairpin pipes with involute shape to the centre of the floor trough. These hairpin pipes are situated in a lower plane than the annular distribution pipe to the centre and in a higher plane from the centre to the outer annular collector pipe. (orig./HP) [de

  9. [Functional aspects of pelvic floor surgery].

    Science.gov (United States)

    Wagenlehner, F M E; Gunnemann, A; Liedl, B; Weidner, W

    2009-11-01

    Pelvic floor dysfunctions are frequently seen in females. The human pelvic floor is a complex structure and heavily stressed throughout female life. Recent findings in the functional anatomy of the pelvic floor have led to a much better understand-ing, on the basis of which enormous improvements in the therapeutic options have arisen. The pelvic floor activity is regulated by three main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor -organs, bladder and rectum. For different reasons laxity in the vagina or its supporting ligaments as a result of altered connective tissue can distort this functional anatomy. A variety of symptoms can derive from these pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, faecal incontinence, obstructive bowel disease syndrome and pelvic pain. Pelvic floor reconstruction is nowadays driven by the concept that in the case of pelvic floor symptoms restoration of the anatomy will translate into restoration of the physiology and ultimately improve the patients' symptoms. The exact surgical reconstruction of the anatomy is there-fore almost exclusively focused on the restoration of the lax pelvic floor ligaments. An exact identification of the anatomic lesions preoperatively is eminently necessary, to allow for an exact anatomic reconstruction with respect to the muscular forces of the pelvic floor. Georg Thieme Verlag Stuttgart * New York.

  10. Pelvic floor physical therapy in urogynecologic disorders.

    Science.gov (United States)

    Kotarinos, Rhonda K

    2003-08-01

    Physical therapists are uniquely qualified to treat pelvic floor dysfunction with conservative management techniques. Techniques associated with incontinence and support functions of the pelvic floor include bladder training and pelvic floor rehabilitation: pelvic floor exercises, biofeedback therapy, and pelvic floor electrical stimulation. Pain associated with mechanical pelvic floor dysfunction can be treated by physical therapists utilizing various manual techniques and modalities. Research documents that conservative management is effective in treating many conditions associated with pelvic floor dysfunction. Research should be conducted to determine if addressing diastasis recti and contracture of the pelvic floor musculature should be a component of the standard physical therapy protocol.

  11. Reliability and Validity of the Floor Transfer Test as a Measure of Readiness for Independent Living Among Older Adults.

    Science.gov (United States)

    Ardali, Gunay; Brody, Lori T; States, Rebecca A; Godwin, Ellen M

    2017-10-20

    The ability to get up from the floor after a fall is a basic skill required for functional independence. Consequently, the inability to safely get down and up from the floor or to perform a floor transfer (FT) may indicate decreased mobility and/or increased frailty. A reliable and valid test of FT ability is a critical part of the clinical decision-making process. The FT test is a simple, performance-based test that can be administered quickly and easily to determine a patient's ability to safely and successfully get down and up from the floor using any movement strategy and without time restriction. The primary purpose of this cross-sectional study was to determine the intrarater reliability and validity of the FT test as a practical alternative to several widely used yet time-consuming measures of physical disability, frailty, and functional mobility. A total of 61 community-dwelling older adults (65-96 years of age) participated in the study divided into 2 separate subsamples: 15 of them in the intrarater reliability part, while the other 46 in the concurrent validity one. In both subsamples, the participants were stratified on the basis of the self-reported levels of FT ability as independent, assisted, and dependent. Intrarater reliability was assessed in 2 separate occasions and scores were analyzed by intraclass correlation coefficient and κ statistics. Concurrent validity of the FT test was assessed against the self-reported FT ability questionnaire, Physical Functioning Scale, Phenotype of Physical Frailty, and the Short Physical Performance Battery. Known-groups validity was tested by determining whether the FT test distinguished between (1) community-dwelling older adults with physical disabilities versus those who without physical disabilities; and (2) community-dwelling older adults who were functionally dependent versus those who were independent. Participants were also categorized on the basis of FT test outcome as independent, assisted, or

  12. School Flooring Factors

    Science.gov (United States)

    McGrath, John

    2012-01-01

    With all of the hype that green building is receiving throughout the school facility-management industry, it's easy to overlook some elements that may not be right in front of a building manager's nose. It is helpful to examine the role floor covering plays in a green building project. Flooring is one of the most significant and important systems…

  13. Casa Sombrilla

    Directory of Open Access Journals (Sweden)

    Franzen, Ulrich

    1963-05-01

    Full Text Available The building is sited on top of a hill, which commands a magnificent view over the river Connecticut. The house is organised on two floor levels and full use is made of the sloping ground. On the lower floor three bedrooms, a dressing room, bathrooms, washing facilities, wardrobes, stores and the boiler room have been located. The top floor includes the main living zone of the house, namely: living-drawing room, dining room, breakfast room, kitchen and services. The structure is metallic and most ingeniously contrived. The roof consists of nine inverted parasol shapes, interconnected by means of three jointed arches. In the top floor the ceilings are covered with Cyprus wood and the floor surface is oak. The house harmonises well with the surrounding scenery. Both the internal and external aspect of the house is richly impressive, this being enhanced by the great simplicity and originality of its design.Se halla emplazada en la cima de un monte, con magníficas vistas sobre el río Connecticut. Se distribuye en dos plantas, según exige la pendiente del terreno: La baja comprende: tres dormitorios, vestidor, baños, lavadero, guardarropas, almacén y sala de calefacción. La alta aloja la zona representativa de la casa: estar-salón, comedor, comedor de desayunos, cocina y aseo. La estructura es metálica y muy ingeniosa. La cubierta se compone de nueve «sombrillas» invertidas y enlazadas entre sí por medio de tres arcos-bisagras. Los techos son de ciprés y los pisos de roble, en el pabellón superior. El aspecto de la casa es armónico con el paisaje, de gran riqueza exterior e interior, y de gran sencillez y originalidad.

  14. Price floors for emissions trading

    International Nuclear Information System (INIS)

    Wood, Peter John; Jotzo, Frank

    2011-01-01

    Price floors in greenhouse gas emissions trading schemes can guarantee minimum abatement efforts if prices are lower than expected, and they can help manage cost uncertainty, possibly as complements to price ceilings. Provisions for price floors are found in several recent legislative proposals for emissions trading. Implementation however has potential pitfalls. Possible mechanisms are government commitments to buy back permits, a reserve price at auction, or an extra fee or tax on acquittal of emissions permits. Our analysis of these alternatives shows that the fee approach has budgetary advantages and is more compatible with international permit trading than the alternatives. It can also be used to implement more general hybrid approaches to emissions pricing. - Research highlights: → Price floors for emissions trading schemes guarantee a minimum carbon price. → Price floors mean that emissions can be less than specified by the ETS cap. → We examine how price floors can relate to different policy objectives. → We compare different mechanisms for implementing a price floor. → We find that a mechanism where there is an extra tax or fee has advantages.

  15. Floor heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U

    1984-02-01

    The question of whether PPC- and VPE-floor heating pipes can endure damage when incompletely imbedded in the floor finish is investigated in an experimental setup. An expansion of the pipe, caused by a temperature increase from 20/sup 0/C to 50/sup 0/C was measured and considered too small to deduce the degree of danger from the damage.

  16. Dampness in dorm rooms and its associations with allergy and airways infections among college students in China: a cross-sectional study.

    Science.gov (United States)

    Sun, Y; Zhang, Y; Sundell, J; Fan, Z; Bao, L

    2009-08-01

    A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June 10, 2006, to survey the association between dampness in dorms, and allergy and airways infections among college students. The health and dampness conditions were self-reported by 3436 students living in 1511 dorm rooms located in 13 buildings on the campus. The buildings were selected according to their positions, construction periods and occupant densities. The symptoms involved wheezing, dry cough during night, rhinitis, eczema, cold/flu, ear inflammation, pneumonia and tuberculosis. The indoor moisture signs were mould/damp spots on walls, ceilings and floors; suspected or ever happened water damage; condensation on windowpane in winter and odours perceived by subjects themselves. There was a significant positive association between condensation and dry cough. Eczema was often reported in rooms with moisture problem. Dampness was a significant risk factor for common cold. Dampness problems in dorms of Chinese students are a risk factor for allergic symptoms, and hence there is a need for dorm environment improvement. Health problems related to ventilation and microbiology problems in dorms should be further studied.

  17. Pelvic floor and sexual male dysfunction

    Directory of Open Access Journals (Sweden)

    Antonella Pischedda

    2013-04-01

    Full Text Available The pelvic floor is a complex multifunctional structure that corresponds to the genito- urinary-anal area and consists of muscle and connective tissue. It supports the urinary, fecal, sexual and reproductive functions and pelvic statics. The symptoms caused by pelvic floor dysfunction often affect the quality of life of those who are afflicted, worsening significantly more aspects of daily life. In fact, in addition to providing support to the pelvic organs, the deep floor muscles support urinary continence and intestinal emptying whereas the superficial floor muscles are involved in the mechanism of erection and ejaculation. So, conditions of muscle hypotonia or hypertonicity may affect the efficiency of the pelvic floor, altering both the functionality of the deep and superficial floor muscles. In this evolution of knowledge it is possible imagine how the rehabilitation techniques of pelvic floor muscles, if altered and able to support a voiding or evacuative or sexual dysfunction, may have a role in improving the health and the quality of life.

  18. Study on Heat Utilization in an Attached Sunspace in a House with a Central Heating, Ventilation, and Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Qingsong Ma

    2018-05-01

    Full Text Available Based on numerical simulations, the heating load reduction effect of an attached sunspace in winter was determined, and the effective heat utilization method and sunspace design were explored. In this paper, we studied the heating load reduction effect using heat from the sunspace and temperature fluctuation of each room at the time of heat use from the sunspace (sending air from the sunspace to the heating, ventilation, and air conditioning (HVAC machine room and taking the air to the adjacent rooms. In the case of the all-day HVAC system, it was confirmed that a larger capacity of sunspace and not sending air from the sunspace to the adjacent room demonstrated a better heating-load reduction effect. Compared with Model Iw (a house with a window on the exterior of the sunspace opened to external air, Model I (a house with an attached sunspace on the second floor could save approximately 41% of the total energy. Model II (a house with the attached sunspace both on the first and second floors could save approximately 84% of the total energy. Sending heat from the sunspace to the adjacent room led to temperature increases in the adjacent rooms. However, if the construction plan is to have the sunspace only on the second floor, the house should be carefully designed, for example, by placing a living room on the second floor.

  19. Maxillary Sinus Floor Augmentation

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Jensen, Janek Dalsgaard

    2017-01-01

    , radiological and histomorphometric outcome as well as complications are presented after maxillary sinus floor augmentation applying the lateral window technique with a graft material, maxillary sinus membrane elevation without a graft material and osteotome-mediated sinus floor elevation with or without...

  20. The effect of sub-floor heating on house-dust-mite populations on floors and in furniture.

    Science.gov (United States)

    de Boer, Rob

    2003-01-01

    It is well known that dehydrating conditions for house dust mites can be created by simply raising the temperature, causing loss of body water and eventually death. Thus, it can be expected that conditions for dust mites are less favourable on floors supplied with sub-floor heating. This was examined in a study of 16 houses with sub-floor heating and 21 without. The pattern of changes in air humidity and temperature on the floors was investigated and compared to known data of the tolerance of dust mites. Also the resident mite populations were compared. Floors with sub-floor heating had, on average, fewer mites, but the difference with unheated floors was small. It was remarkable that mite numbers were also lower in upholstered furniture. Another important observation was that some houses with sub-floor heating had high mite numbers, indicating that this type of heating is compatible with a thriving mite population. Temperature and humidity conditions of heated floors may allow mites not only to survive, but also to remain active in winter. A moderate increase in temperature, a moderate decrease in (absolute) air humidity, or a combination of both, will suffice to keep the humidity all winter below the Critical Equilibrium Humidity, the level of air humidity that is critical for mite growth and reproduction, hence for allergen production. However, it is argued that measures to suppress allergen production by house dust mites are likely to be far more effective if taken in summer rather than in winter.

  1. Timbral aspects of reproduced sound in small rooms. II

    DEFF Research Database (Denmark)

    Bech, Søren

    1996-01-01

    A single loudspeaker with frequency-dependent directivity characteristics, positioned in a room of normal size with frequency-dependent absorption coefficients of the room surfaces, has been simulated using an electroacoustic setup. The model included the direct sound, seventeen individual...... reflections and the reverberant field. The threshold of detection, and just-noticeable differences for an increase in level were measured for individual reflections. The results have confirmed that the first-order floor reflection is likely to contribute individually to the timbre of reproduced noise. However......, for a speech signal none of the investigated reflections will contribute individually to the timbre. It is suggested that the threshold of detection is determined by the spectral changes in the dominant frequency range of 500 Hz to 2 kHz. For increases in the level of individual reflections, the most likely...

  2. Development of floor smear sampler (floor radioactive contamination measuring instrument) for nuclear facilities

    International Nuclear Information System (INIS)

    Miyagawa, Minoru; Ito, Haruo; Nozawa, Katsuro; Shinohara, Yotaro; Hashimoto, Hiroshi.

    1980-01-01

    The control of the floor contamination with radioactive substances in nuclear facilities is strictly carried out by smear method, in which the contaminants on floor surfaces are wiped off with filter papers or cloths, and the contamination density on the floor surfaces is measured through their intensity of radioactivity. This wiping work is laborious since it is carried out in leaning-over posture when many samples must be taken in wide floor area. Therefore, to achieve labor saving in this work, an automatic sampler was developed. In the floor smear sampler developed, samples are taken on long band type wiping cloths only by handle operation, and the sample numbers are printed. When many samples are taken in wide floor area, this is especially effective, and the labor saving by 1/3 to 1/2 can be achieved. At present, this sampler is put in practical use in Hamaoka Nuclear Power Station. At the time of trial manufacture, the method of wiping, the mechanisms of wiping, cloth feeding and running, the contact pressure and the number of times of wiping affecting wiping efficiency and the required torque of a motor were examined. The developed sampler is that of constant contact pressure, vibration wiping type, and the rate of sampling is 10 sec per one sample. 100 samples can be taken on one roll of wiping cloth. The results of performance test are reported. (Kako, I.)

  3. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Anthony Cuffe; Thomas Oren

    2005-01-01

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on work-flow processes and ergonomic attributes. The renovation was performed in two phases during the summer of 2004, with one phase occurring during machine operations and the latter, more extensive phase, occurring during our semi-annual shutdown period. The new facility takes advantage of advances in display technology, analog and video signal management, server technology, ergonomic workspace design, lighting engineering, acoustic ceilings and raised flooring solutions to provide a marked improvement in the overall environment of machine operations

  4. Linear Alkylbenzenesulfonates in indoor Floor Dust

    DEFF Research Database (Denmark)

    Madsen, Jørgen Øgaard; Wolkoff, Peder; Madsen, Jørgen Øgaard

    1999-01-01

    The amount of Linear Alkylbenzenesulfonates (LAS) in the particle fraction of floor dust sampled from 7 selected public buildings varied between 34 and 1500 microgram per gram dust, while the contents of the fibre fractions generally were higher with up to 3500 microgram LAS/g dust. The use...... of a cleaning agent with LAS resulted in an increase of the amount of LAS in the floor dust after floor wash relative to just before floor wash. However, the most important source of LAS in the indoor floor dust appears to be residues of detergent in clothing. Thus, a newly washed shirt contained 2960 microgram...

  5. Dose field research of analysis room for in-hospital neutron irradiator

    International Nuclear Information System (INIS)

    Zhang Zizhu; Song Mingzhe; Li Wei; Chen Jun; Yang Yong; Li Yiguo

    2012-01-01

    Neutron equivalent dose rate and y ray dose rate inside the analysis room of the in-hospital neutron irradiator (IHNI) and outdoor were measured. The results show that γ ray dose rate inside the analysis room exceeds calculation value many times and γ/ ray dose rate outdoor is higher than supervision region dose limit of 7.5 μSv/h. According to the measurement results and the Monte Carlo simulation, the following shielding plan was adopted. Lead shielding with thickness of 16 cm was installed on the wall, which faces the neutron beam, to shield γ ray, and lithium polyethylene plate with thickness of l cm was installed on all the wall (not including ceiling and floor) to shield scattering neutron. After shielding transformation, the highest γ ray dose rate point inside the analysis room decreased 277 times, the neutron equivalent dose rate decreased 5.8 times, and the outdoor γ/ray dose rate decreased nearly 90 times. (authors)

  6. Effects of Floor Covering Resistance of a Radiant Floor on System Energy and Exergy Performances

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Shukuya, Masanori; Olesen, Bjarne W.

    2016-01-01

    Floor covering resistance (material and thickness) can be influenced by subjective choices (architectural design, interior design, texture, etc.) with significant effects on the performance of a radiant heating and cooling system. To study the effects of floor covering resistance on system...... performance, a water-based radiant floor heating and cooling system (dry, wooden construction) was considered to be coupled to an air-to-water heat pump, and the effects of varying floor covering resistances (0.05 m2K/W, 0.09 m2K/W and 0.15 m2K/W) on system performance were analyzed in terms of energy...... and exergy. In order to achieve the same heating and cooling outputs, higher average water temperatures are required in the heating mode (and lower temperatures in the cooling mode) with increasing floor covering resistance. These temperature requirements decrease the heat pump’s performance (lower...

  7. Effects of flooring on required coefficient of friction: Elderly adult vs. middle-aged adult barefoot gait.

    Science.gov (United States)

    Rozin Kleiner, Ana Francisca; Galli, Manuela; Araujo do Carmo, Aline; Barros, Ricardo M L

    2015-09-01

    The aim of this study was to investigate the effect of flooring on barefoot gait according to age and gender. Two groups of healthy subjects were analyzed: the elderly adult group (EA; 10 healthy subjects) and the middle-aged group (MA; 10 healthy subjects). Each participant was asked to walk at his or her preferred speed over two force plates on the following surfaces: 1) homogeneous vinyl (HOV), 2) carpet, 3) heterogeneous vinyl (HTV) and 4) mixed (in which the first half of the pathway was covered by HOV and the second by HTV). Two force plates (Kistler 9286BA) embedded in the data collection room floor measured the ground reaction forces and friction. The required coefficient of friction (RCOF) was analyzed. For the statistical analysis, a linear mixed-effects model for repeated measures was performed. During barefoot gait, there were differences in the RCOF among the flooring types during the heel contact and toe-off phases. Due to better plantar proprioception during barefoot gait, the EA and MA subjects were able to distinguish differences among the flooring types. Moreover, when the EA were compared with the MA subjects, differences could be observed in the RCOF during the toe-off phase, and gender differences in the RCOF could also be observed during the heel contact phase in barefoot gait. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. Initial decontamination of the equipment decontamination room at the West Valley Demonstration Project. Topical report, September 1983-May 1985

    International Nuclear Information System (INIS)

    Meigs, R.A.

    1985-12-01

    The purpose of this report is to document the initial decontamination of the Equipment Decontamination Room (EDR). The effort spanned a two-year period and included packaging and removal of waste; grinding away contaminated concrete floors; pump-out and spraydown of an equipment soaking pit; washing and painting of walls, equipment, and floors; refurbishment of utilities and various pieces of equipment; and load tests of EDR and Chemical Process Cell (CPC) cranes. After decontamination, the EDR was converted into a waste handling area for the decommissioning of the CPC

  9. Characteristics Air Flow in Room Chamber Test Refrigerator Household Energy Consumption with Inlet Flow Variation

    Science.gov (United States)

    Susanto, Edy; Idrus Alhamid, M.; Nasruddin; Budihardjo

    2018-03-01

    Room Chamber is the most important in making a good Testing Laboratory. In this study, the 2-D modeling conducted to assess the effect placed the inlet on designing a test chamber room energy consumption of household refrigerators. Where the geometry room chamber is rectangular and approaching the enclosure conditions. Inlet varied over the side parallel to the outlet and compared to the inlet where the bottom is made. The purpose of this study was to determine and define the characteristics of the airflow in the room chamber using CFD simulation. CFD method is used to obtain flow characteristics in detail, in the form of vector flow velocity and temperature distribution inside the chamber room. The result found that the position of the inlet parallel to the outlet causes air flow cannot move freely to the side of the floor, even flow of air moves up toward the outlet. While by making the inlet is below, the air can move freely from the bottom up to the side of the chamber room wall as well as to help uniform flow.

  10. A comparative study on thermal efficiency between the present floor and a ceramic floor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y.M.; Kim, K.S. [Korea Institute of Science and Technology, Seoul (Korea, Republic of); Choi, B.S. [Kyung Hee University, Yongin (Korea, Republic of); Ko, J.S.; Park, S.K. [Bomwoo and Co. LTD., Kwangju (Korea, Republic of)

    1999-04-01

    A ceramic floor with improved thermal conductivity and efficiency has been developed in this study. The new ceramic floor minimizes the shrinkage rate to below 0.07% and shows almost no cleavage. There is no need to repair the ceramic floor because its bottom surface is flat. It especially shows an excellent performance in the test of a compressive strength (300 kg/cm{sup 2} based on 28 days), a flexural strength (64 kg/cm{sup 2} based on 28 days), and a convenient pressing. It is lighter than the present floor and it is expected to be applicable for a self-leveling ceramic motar in the residences and apartments. It shows an excellent character in the thermal conductivity and other physical properties compare to the present cement mortar. 5 refs., 3 figs., 2 tabs.

  11. Floors: Care and Maintenance.

    Science.gov (United States)

    Post Office Dept., Washington, DC.

    Guidelines, methods and policies regarding the care and maintenance of post office building floors are overviewed in this handbook. Procedures outlined are concerned with maintaining a required level of appearance without wasting manpower. Flooring types and characteristics and the particular cleaning requirements of each type are given along with…

  12. Building with electromagnetic shield structure for individual floors

    International Nuclear Information System (INIS)

    Takahashi, T.; Nakamura, M.; Yabana, Y.; Ishikawa, T.; Nagata, K.

    1991-01-01

    This invention relates to a building having a floor-by-floor electromagnetic shield structure well-suited for application to an information network system in which an electromagnetically shielded space is divided by individual floors and electric waves are utilized within the building on a floor-by-floor basis. (author). 8 figs

  13. Building with electromagnetic shield structure for individual floors

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, T; Nakamura, M; Yabana, Y; Ishikawa, T; Nagata, K

    1991-09-10

    This invention relates to a building having a floor-by-floor electromagnetic shield structure well-suited for application to an information network system in which an electromagnetically shielded space is divided by individual floors and electric waves are utilized within the building on a floor-by-floor basis. (author). 8 figs.

  14. Evaluation of room-scattered neutrons at the JNC Tokai neutron reference field

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Tadayoshi; Tsujimura, Norio [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan). Tokai Works; Oyanagi, Katsumi [Japan Radiation Engineering Co., Ltd., Hitachi, Ibaraki (Japan)

    2002-09-01

    Neutron reference fields for calibrating neutron-measuring devices in JNC Tokai Works are produced by using radionuclide neutron sources, {sup 241}Am-Be and {sup 252}Cf sources. The reference field for calibration includes scattered neutrons from the material surrounding sources, wall, floor and ceiling of the irradiation room. It is, therefore, necessary to evaluate the scattered neutrons contribution and their energy spectra at reference points. Spectral measurements were performed with a set of Bonner multi-sphere spectrometers and the reference fields were characterized in terms of spectral composition and the fractions of room-scattered neutrons. In addition, two techniques stated in ISO 10647, the shadow-cone method and the polynomial fit method, for correcting the contributions from the room-scattered neutrons to the readings of neutron survey instruments were compared. It was found that the two methods gave an equivalent result within a deviation of 3.3% at a source-to-detector distance from 50cm to 500cm. (author)

  15. Evaluation of room-scattered neutrons at the JNC Tokai neutron reference field

    International Nuclear Information System (INIS)

    Yoshida, Tadayoshi; Tsujimura, Norio

    2002-01-01

    Neutron reference fields for calibrating neutron-measuring devices in JNC Tokai Works are produced by using radionuclide neutron sources, 241 Am-Be and 252 Cf sources. The reference field for calibration includes scattered neutrons from the material surrounding sources, wall, floor and ceiling of the irradiation room. It is, therefore, necessary to evaluate the scattered neutrons contribution and their energy spectra at reference points. Spectral measurements were performed with a set of Bonner multi-sphere spectrometers and the reference fields were characterized in terms of spectral composition and the fractions of room-scattered neutrons. In addition, two techniques stated in ISO 10647, the shadow-cone method and the polynomial fit method, for correcting the contributions from the room-scattered neutrons to the readings of neutron survey instruments were compared. It was found that the two methods gave an equivalent result within a deviation of 3.3% at a source-to-detector distance from 50cm to 500cm. (author)

  16. Live weight and body measurements of male and female native ducks raised in different raising systems

    Directory of Open Access Journals (Sweden)

    Kadir Önk

    2018-05-01

    Full Text Available ABSTRACT The purpose of this study was to determine live weight and body measurements of male and female native ducks raised in different raising systems. One hundred and twenty native ducks (60 males, 60 females were used in the study. The ducks were raised in deep litter floor and cage systems. Live weight and body values were measured every two weeks, until they were 56 days old. Three-parameter logistic regression and Gompertz model were used to determine growth model of male and female ducks. Interactions of time-raising system and time-sex were statistically significant in terms of live weight. At the end of eight weeks, live weights of ducks raised in deep litter floor were higher than ducks raised in cage system. In addition, live weights of male ducks were higher than female ducks. Consequently, deep litter floor is more appropriate for live weight in native ducks. Accuracy rate of Three-parameter Logistic and Gompertz models for estimation of growth in ducks was between 0.91-0.95 and similar results were obtained from both models. The Gompertz model is appropriate for the data structure of this study because it contains fewer iterations than the Three-Parameter Logistic model.

  17. Flooring choices for newborn ICUs.

    Science.gov (United States)

    White, R D

    2007-12-01

    Floors are a major element of newborn intensive care unit (NICU) construction. They provide visual cues, sound control, and with certain materials, some degree of physical comfort for workers. Flooring materials may entail a significant cost for installation and upkeep and can have substantial ecological impact, both in the choice of the flooring itself, as well as the substances used to clean it. In this article the important aspects to consider for each factor are explored and recommendations are offered for appropriate choices in various NICU areas.

  18. Design aspects of the Alpha Repository. VII. Summary of results for the conceptual facility layout, room stability analysis, and equipment selection. Project summary report RSI-0033

    Energy Technology Data Exchange (ETDEWEB)

    Gnirk, P.F.; Grams, W.H.; Zeller, T.J.

    1978-11-03

    In 1975, RE/SPEC Inc. analyzed various design engineering aspects of an Alpha Repository for the disposal and isolation of packages of low-level solid waste and sealed metal canisters of spent fuel cladding waste. The proposed site was located in southeastern New Mexico, with candidate disposal horizons situated in massive bedded salt at depths of 580 to 825 m. The canisters would be emplaced in vertical drillholes in the floors of disposal rooms, and the packages of solid waste subsequently stacked on the floors. Consideration was given to various conceptual facility layouts, the structural stability of the disposal rooms, appropriate excavation/haulage systems, and equipment availability for drilling the canister emplacement holes. This report summarizes the results of the entire study.

  19. Residencia del colegio de Cristo, en Cambridge - Gran Bretaña

    Directory of Open Access Journals (Sweden)

    Denys Lasdun & Partners, Arquitectos

    1973-03-01

    Full Text Available This structure rises by successive terraces, extending from within the existing college onto King's Street but keeping the traditional tone of university isolation from the rest of the city. The main floor contains utility rooms, shops, porter's lodging, sitting rooms, lecture halls, conference rooms, bar, and parking access. The upper floors house the living quarters, i.e. rooms with bath. A reinforced concrete base supports the upper, prefabricated floors.El edificio se levanta —por medio de terrazas sucesivas— desde el colegio existente hasta volar sobre la calle King, recogiendo el tradicional concepto de apertura hacia dentro y aislamiento respecto de la ciudad. La planta baja alberga: - las zonas de instalaciones; - tiendas; - vivienda del conserje; - estancias nobles, tales como salas de lectura, coloquios y bar; - acceso al aparcamiento. En las plantas altas están situadas las habitaciones con baño. La estructura de la planta baja es de hormigón armado y soporta las plantas elevadas, construidas a base de elementos prefabricados.

  20. Formaldehyde and TVOC emission behavior of laminate flooring by structure of laminate flooring and heating condition.

    Science.gov (United States)

    An, Jae-Yoon; Kim, Sumin; Kim, Hyun-Joong

    2011-03-15

    Formaldehyde was measured with a desiccator, a 20 L chamber and the FLEC method. The formaldehyde emission rate from laminate was the highest at 32 °C using the desiccator, which then decreased with time. The formaldehyde emission using the 20 L small chamber and FLEC showed a similar tendency. There was a strong correlation between the formaldehyde and total volatile organic compounds (TVOCs) with both types of floorings using the two different methods. The formaldehyde emission rate and TVOC results were higher when tested using the FLEC method than with the 20 L small chamber method. The emission rate was affected by the joint edge length in laminate flooring. Toluene, ethylbenzene and xylene were the main VOCs emitted from laminate flooring, and there were more unidentified VOCs emitted than identified VOCs. The samples heated with a floor heating system emitted more formaldehyde than those heated using an air circulation system due to the temperature difference between the bottom panel and flooring. The TVOC emission level of the samples was higher when an air circulation system was used than when a floor heating system was used due to the high ventilation rate. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Crustal Ages of the Ocean Floor - Poster

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Crustal Ages of the Ocean Floor Poster was created at NGDC using the Crustal Ages of the Ocean Floor database draped digitally over a relief of the ocean floor...

  2. Improving elasticity and hydroinsulation of supports in an explosives storage room as well as adaptation of its parts for temporary storage room during construction of the Czeczott black coal mine

    Energy Technology Data Exchange (ETDEWEB)

    Janusz, E; Perun, S

    1986-05-01

    Design and construction are discussed of an explosives storage room in sandstone strata at 500 m depth in the Czeczott mine. The storage room has a capacity of 3000 kg of explosives, a volume of 5932 m/sup 3/ and consists of 7 storage chambers. Design of supports and liners was aimed at increasing their elasticity and reducing water hazards. Support system consists of the following elements: LP arched steel supports, a 30-40 cm thick layer of slag, a waterproof layer of textiles with a rubber cover, brick liners 40 cm thick. The roof zone of the brick liners is covered by 2 layers of waterproof mortar. Perforated pipes are installed in the slag layer close to the floor. Use of the slag layer increases elasticity of the support system; waterproof textiles, rubber, waterproof mortar and perforated pipes eliminate water hazards as well as hazards associated with stray currents. Design of the explosive storage room is shown in 5 schemes.

  3. Dos obras de Friedrich F. Haindl, Alemania Federal

    Directory of Open Access Journals (Sweden)

    Editorial, Equipo

    1973-07-01

    Full Text Available The Asylum of Wasserburg. It is a brick construction, faced with pre-manufactured concrete pieces; its plan is rectangular and consists of: cellar (under ground, ground floor and six stories. Arrangement of cellar: kitchen with its accessory rooms, laundry, storing rooms, as well as lavatories and installations. The entry is on the ground floor, with a forged iron front door which communicates with the spacious interior hall. This floor includes: dinnig room, chapel, library and administrative rooms. The first floor is assigned to: personnel and the Sisters' rooms, including a refectory, and the appartment of the janitor. The following four floors contain the total of the residents' rooms, with a common hall on each floor. On the top floor, the centre for medical assistance with rooms of different capacities is installed. The whole is completed by a garage and a garden. The residence for old people of Berchting. It has been installed in an old convent of two floors, adding a new building which consists of: cellar, ground floor, and two and three storeys. Old and new part arc connected by means of a glass aisle. The old building contains: rooms for personnel, Sisters and nurses, the chaplain's appartments; the kitchen, dining-room, refectory and living-room; administrative rooms, lavatories and services, storing rooms and workshops. In the new building are installed the rooms for the old; the rooms for boiler, oil tanks for heating, storing rooms, workshops; dinnig-room and lobby near the connexion aisle; main kitchen and small kitchens on each floor; personnel diningroom, laundry, lavatories, living-rooms and common terrace, as well as the centre for medical assistance with 22 beds. Each bedroom has its washbasin and incorporated closet, and all the resident's rooms have individual balconies. The whole new construction has been buil with concrete, harmonizing with the large glass walls of the aisle, with the common rooms and the bed-rooms

  4. 75 FR 66126 - Multilayered Wood Flooring From China

    Science.gov (United States)

    2010-10-27

    ...)] Multilayered Wood Flooring From China AGENCY: United States International Trade Commission. ACTION: Institution... flooring, provided for in subheadings 4409.10, 4409.29, 4412.31, 4412.32, 4412.39, 4412.94, 4412.99, 4418... multilayered wood flooring. The following companies are members of the CAHP: Anderson Hardwood Floors, LLC...

  5. 75 FR 79019 - Multilayered Wood Flooring From China

    Science.gov (United States)

    2010-12-17

    ...)] Multilayered Wood Flooring From China Determinations On the basis of the record \\1\\ developed in the subject... imports from China of multilayered wood flooring, provided for in subheadings 4409.10, 4409.29, 4412.31... multilayered wood flooring. The following companies are members of the CAHP: Anderson Hardwood Floors, LLC...

  6. Mode of delivery and Pelvic floor disorder

    International Nuclear Information System (INIS)

    Noor, R.; Neelam, H.; Bashir, M.S.

    2017-01-01

    Objective: To compare pelvic floor dysfunction in non pregnant women who had delivered vaginally versus those with cesarean delivery. Methodology: The prevalence of pelvic floor disorders among non pregnant women was assesses by using a standardized tool pelvic floor distress inventory short form (PFDI-20). Data was collected from Jinnah Hospital Lahore, Pakistan. Results: Total numbers of participants were 278. 47.12% subjects had moderate, 36.69% miner and 16.19% had severe pelvic floor dysfunction. The symptoms of pelvic organ prolapse were more prevalent (mean value is 59.1876) than Urinary Distress (mean value is 40.5426), while the Colorectal-Anal Distress (mean value is 35.9150) were least prevalent. Conclusion: Pelvic floor disorders are very common among females and are strongly associated with mode of delivery. Although spontaneous vaginal birth was extensively associated with pelvic floor disorders the instrumental delivery affects most. (author)

  7. Functional anatomy of pelvic floor

    Directory of Open Access Journals (Sweden)

    Salvatore Rocca Rossetti

    2016-03-01

    Full Text Available Generally, descriptions of the pelvic floor are discordant, since its complex structures and the complexity of pathological disorders of such structures; commonly the descriptions are sectorial, concerning muscles, fascial developments, ligaments and so on. On the contrary to understand completely nature and function of the pelvic floor it is necessary to study it in the most unitary view and in the most global aspect, considering embriology, philogenesy, anthropologic development and its multiple activities others than urological, gynaecological and intestinal ones. Recent acquirements succeeded in clarifying many aspects of pelvic floor activity, whose musculature has been investigated through electromyography, sonography, magnetic resonance, histology, histochemistry, molecular research. Utilizing recent research concerning not only urinary and gynecologic aspects but also those regarding statics and dynamics of pelvis and its floor, it is now possible to study this important body part as a unit; that means to consider it in the whole body economy to which maintaining upright position, walking and behavior or physical conduct do not share less than urinary, genital, and intestinal functions. It is today possible to consider the pelvic floor as a musclefascial unit with synergic and antagonistic activity of muscular bundles, among them more or less interlaced, with multiple functions and not only the function of pelvic cup closure.

  8. External Hand Forces Exerted by Long-Term Care Staff to Push Floor-Based Lifts: Effects of Flooring System and Resident Weight.

    Science.gov (United States)

    Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C

    2016-09-01

    The aim of this study was to investigate the effects of flooring type and resident weight on external hand forces required to push floor-based lifts in long-term care (LTC). Novel compliant flooring is designed to reduce fall-related injuries among LTC residents but may increase forces required for staff to perform pushing tasks. A motorized lift may offset the effect of flooring on push forces. Fourteen female LTC staff performed straight-line pushes with two floor-based lifts (conventional, motor driven) loaded with passengers of average and 90th-percentile resident weights over four flooring systems (concrete+vinyl, compliant+vinyl, concrete+carpet, compliant+carpet). Initial and sustained push forces were measured by a handlebar-mounted triaxial load cell and compared to participant-specific tolerance limits. Participants rated pushing difficulty. Novel compliant flooring increased initial and sustained push forces and subjective ratings compared to concrete flooring. Compared to the conventional lift, the motor-driven lift substantially reduced initial and sustained push forces and perceived difficulty of pushing for all four floors and both resident weights. Participants exerted forces above published tolerance limits only when using the conventional lift on the carpet conditions (concrete+carpet, compliant+carpet). With the motor-driven lift only, resident weight did not affect push forces. Novel compliant flooring increased linear push forces generated by LTC staff using floor-based lifts, but forces did not exceed tolerance limits when pushing over compliant+vinyl. The motor-driven lift substantially reduced push forces compared to the conventional lift. Results may help to address risk of work-related musculoskeletal injury, especially in locations with novel compliant flooring. © 2016, Human Factors and Ergonomics Society.

  9. 76 FR 76435 - Multilayered Wood Flooring From China

    Science.gov (United States)

    2011-12-07

    ...)] Multilayered Wood Flooring From China Determinations On the basis of the record \\1\\ developed in the subject... multilayered wood flooring, provided for in subheadings 4409.10, 4409.29, 4412.31, 4412.32, 4412.39, 4412.94... flooring. The following companies are members of the CAHP: Anderson Hardwood Floors, LLC, Fountain Inn, SC...

  10. Effects of different floor housing systems on the welfare of fast-growing broilers with an extended fattening period

    Directory of Open Access Journals (Sweden)

    E. Çavuşoğlu

    2018-01-01

    Full Text Available This study was made to investigate the long-term effects of different floor housing systems on the welfare of fast-growing broilers. The experiment was performed on 210-day-old fast-growing hybrid male chickens with identical conditions until 47 days of age. Animal-based welfare parameters were measured to investigate the welfare level in the group housed on deep litter, a litter and slat system, and a slatted floor, with five replicates for each group. Results showed that the main welfare indicators in live birds, such breast dirtiness, plumage score, footpad lesion, and hock burn lesion, were negatively affected in broilers kept on conventional deep-litter floor housing. But hemorrhage or lesion scores of the breast and shoulder of broilers in slat floor housing were found to be significantly greater than in conventional deep litter as a result of a heavy body weight at a greater slaughter age (p < 0.05. Pathologically, the prevalence of footpad and hock joint dermatitis was very high in the deep-litter housing system. Femoral head necrosis was not observed in any floor housing group. The results indicated that keeping broilers on a slat flooring system is preferable for younger slaughter ages and for a lighter slaughter weight. When considering the relationship between animal welfare and production economy, moving from one floor house system to another floor housing system should be carefully weighted in future decisions. Moreover, further investigations are needed in order to examine the incidence of joint and bone problems with muscle inflammation in heavier broilers in commercial conditions.

  11. PVC--as flooring material--and its association with incident asthma in a Swedish child cohort study.

    Science.gov (United States)

    Larsson, M; Hägerhed-Engman, L; Kolarik, B; James, P; Lundin, F; Janson, S; Sundell, J; Bornehag, C G

    2010-12-01

    The Dampness in Buildings and Health study (DBH) started in the year 2000 in Värmland, Sweden, with a baseline questionnaire sent to all children (n = 14,077) aged 1-6. Five years later, a follow-up questionnaire was sent to the children who were 1-3 years at baseline. A total of 4779 children participated in both the baseline and the follow-up studies and constitute the study population in this cohort study. The aim of this study was to examine the association between exposure to PVC-flooring in the child's and parent's bedroom in homes of children aged 1-3 and the incidence of asthma, rhinitis, and eczema during the following 5-year period. Adjusted analyses showed that the incidence of asthma among children was associated with PVC-flooring in the child's bedroom (AOR 1.52; 95% CI 0.99-2.35) and in the parent's bedroom (1.46; 0.96-2.23). The found risks were on borderline of significance and should therefore be interpreted with caution. There was further a positive relationship between the number of rooms with PVC-flooring and the cumulative incidence of asthma. PVC-flooring was found to be a stronger risk factor for incident asthma in multifamily homes when compared with single-family houses and in smoking families compared with non-smoking families and in women. These longitudinal data from the DBH study found an association between the presence of PVC-flooring in the home and incident asthma in children. However, earlier results from the DBH study have shown that PVC-flooring is one important source for phthalates in indoor dust, and exposure to such phthalates was found to be associated with asthma and allergy among children. This emphasizes the need for prospective studies that focus on the importance of prenatal and neonatal exposure to phthalates in the development of asthma and allergy in children. © 2010 John Wiley & Sons A/S.

  12. Radiant Floor Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2008-01-01

    In many countries, hydronic radiant floor systems are widely used for heating all types of buildings such as residential, churches, gymnasiums, hospitals, hangars, storage buildings, industrial buildings, and smaller offices. However, few systems are used for cooling.This article describes a floor...... cooling system that includes such considerations as thermal comfort of the occupants, which design parameters will influence the cooling capacity and how the system should be controlled. Examples of applications are presented....

  13. Mass concentration and elemental composition of indoor PM 2.5 and PM 10 in University rooms in Thessaloniki, northern Greece

    Science.gov (United States)

    Gemenetzis, Panagiotis; Moussas, Panagiotis; Arditsoglou, Anastasia; Samara, Constantini

    The mass concentration and the elemental composition of PM 2.5 and PM 10 were measured in 40 rooms (mainly offices or mixed office-lab rooms, and photocopying places) of the Aristotle University of Thessaloniki, northern Greece. A total of 27 major, minor and trace elements were determined by ED-XRF analysis. The PM 2.5/PM 10 concentration ratios averaged 0.8±0.2, while the corresponding elemental ratios ranged between 0.4±0.2 and 0.9±0.2. The concentrations of PM 2.5 and PM 10 were significantly higher (by 70% and 50%, respectively) in the smokers' rooms compared to the non-smokers' places. The total elemental concentrations were also higher in the smokers' rooms (11.5 vs 8.2 μg m -3 for PM 2.5, and 10.3 vs 7.6 μg m -3 for PM 2.5-10). Fine particle concentrations (PM 2.5) were found to be quite proportional to smoking strength. On the contrary, the two environments exhibited similar coarse (PM 2.5-10) particle fractions not related to the number of cigarettes smoked. A slight decrease of particle concentrations with increasing the floor level was also observed, particularly for PM 2.5, suggesting that high-level floors are less impacted by near ground-level sources like traffic emissions. Finally, the removal efficiency of air purification systems was evaluated.

  14. Magnetic resonance imaging of pelvic floor dysfunction.

    Science.gov (United States)

    Lalwani, Neeraj; Moshiri, Mariam; Lee, Jean H; Bhargava, Puneet; Dighe, Manjiri K

    2013-11-01

    Pelvic floor dysfunction is largely a complex problem of multiparous and postmenopausal women and is associated with pelvic floor or organ descent. Physical examination can underestimate the extent of the dysfunction and misdiagnose the disorders. Functional magnetic resonance (MR) imaging is emerging as a promising tool to evaluate the dynamics of the pelvic floor and use for surgical triage and operative planning. This article reviews the anatomy and pathology of pelvic floor dysfunction, typical imaging findings, and the current role of functional MR imaging. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. [Continuous improvement of portable domestic pelvic floor neuromuscular electrical stimulation on the pelvic floor function of patients with urinary incontinence].

    Science.gov (United States)

    Sun, Zhijing; Zhu, Lan; Lang, Jinghe; Wang, Wei; Shi, Honghui; Pang, Hongxia; Shi, Xinwen

    2015-12-01

    To evaluate continuous improvement of portable domestic pelvic floor neuromuscular electrical stimulation on the pelvic floor function of patients with stress urinary incontinence after short-term pelvic floor electrophysiological treatment in hospital. Totally 60 women with stress urinary incontinence were recruited for this randomized controlled trial. The control group including a total of 30 patients, only received 4 weeks pelvic floor electrophysiological treatment in the hospital. Family consolidation treatment group (experimental group) including 30 patients, after 4-week treatment in hospital, received 12-week of pelvic floor neuromuscular electrical stimulation using portable electrical stimulator at home under the guidance of doctors. In post-treatment 6 months and 9 months, 1-hour pad test was measured for urine leakage, pelvic floor electrical physiological parameters were assessed, and subjective improvement of symptoms of urinary incontinence were evaluated. All these data were analysed to compare the effect of the two groups. In 9 months after treatment, average change of urine leakage, the control group and experiment group were (75±24)% versus (99±3)%, the difference was statistically significant (Pcontinuous improvement of pelvic floor function.

  16. Modular Flooring System

    Science.gov (United States)

    Thate, Robert

    2012-01-01

    The modular flooring system (MFS) was developed to provide a portable, modular, durable carpeting solution for NASA fs Robotics Alliance Project fs (RAP) outreach efforts. It was also designed to improve and replace a modular flooring system that was too heavy for safe use and transportation. The MFS was developed for use as the flooring for various robotics competitions that RAP utilizes to meet its mission goals. One of these competitions, the FIRST Robotics Competition (FRC), currently uses two massive rolls of broadloom carpet for the foundation of the arena in which the robots are contained during the competition. The area of the arena is approximately 30 by 72 ft (approximately 9 by 22 m). This carpet is very cumbersome and requires large-capacity vehicles, and handling equipment and personnel to transport and deploy. The broadloom carpet sustains severe abuse from the robots during a regular three-day competition, and as a result, the carpet is not used again for competition. Similarly, broadloom carpets used for trade shows at convention centers around the world are typically discarded after only one use. This innovation provides a green solution to this wasteful practice. Each of the flooring modules in the previous system weighed 44 lb (.20 kg). The improvements in the overall design of the system reduce the weight of each module by approximately 22 lb (.10 kg) (50 %), and utilize an improved "module-to-module" connection method that is superior to the previous system. The MFS comprises 4-by-4-ft (.1.2-by- 1.2-m) carpet module assemblies that utilize commercially available carpet tiles that are bonded to a lightweight substrate. The substrate surface opposite from the carpeted surface has a module-to-module connecting interface that allows for the modules to be connected, one to the other, as the modules are constructed. This connection is hidden underneath the modules, creating a smooth, co-planar flooring surface. The modules are stacked and strapped

  17. PVC flooring at home and development of asthma among young children in Sweden, a 10-year follow-up.

    Science.gov (United States)

    Shu, H; Jönsson, B A; Larsson, M; Nånberg, E; Bornehag, C-G

    2014-06-01

    The incidence of asthma and allergy has increased throughout the developed world over the past decades. During the same period of time, the use of industrial chemicals such as phthalates, commonly used as plasticizers in polyvinylchloride (PVC) flooring material, has increased. The aim of this study was to investigate whether PVC flooring in the home of children in the age of 1-5 years is associated with the development of asthma in 5- and 10-year follow-up investigations (n = 3228). Dampness in Buildings and Health Study (DBH Study) commenced in 2000 in Värmland, Sweden. The current analyses included subjects who answered all baseline and follow-up questionnaires. Logistic regression analyses were applied to questionnaire results. Children who had PVC floorings in the bedroom at baseline were more likely to develop doctor-diagnosed asthma during the following 10-year period when compared with children living without. There were indications that PVC flooring in the parents' bedrooms was strongly associated with the new cases of doctor-diagnosed asthma when compared with child's bedroom. Our results suggest that PVC flooring exposure during pregnancy could be a critical period in the development of asthma in children at a later time; prenatal exposure and measurements of phthalate metabolites should be included in the future. This study has found that PVC flooring material in early life was related to incidence of asthma during the following 10 years when compared with other flooring materials and especially when comparing with wood flooring type.The study has further indicated that PVC flooring in the parents’ bedroom (proxy for prenatal exposure) was more associated with the development of asthma than PVC in the child’s bedroom was. Our results suggest that PVC flooring exposure during pregnancy could be a critical period in the development of asthma in children at a later time. In future prospective cohort study, prenatal exposure and measurements of

  18. Knowledge of the pelvic floor in nulliparous women

    OpenAIRE

    Neels, Hedwig; Wyndaele, Jean-Jacques; Tjalma, Wiebren A. A.; De Wachter, Stefan; Wyndaele, Michel; Vermandel, Alexandra

    2016-01-01

    [Purpose] Proper pelvic floor function is important to avoid serious dysfunctions including incontinence, prolapse, and sexual problems. The current study evaluated the knowledge of young nulliparous women about their pelvic floor and identified what additional information they wanted. [Subjects and Methods] In this cross-sectional survey, a validated, 36 item questionnaire was distributed to 212 nulliparous women. The questionnaire addressed demography, pelvic floor muscles, pelvic floor dys...

  19. Container floor at high temperatures

    International Nuclear Information System (INIS)

    Reutler, H.; Klapperich, H.J.; Mueller-Frank, U.

    1978-01-01

    The invention describes a floor for container which is stressed at high, changing temperatures and is intended for use in gas-cooled nuclear reactors. Due to the downward cooling gas flow in these types of reactor, the reactor floor is subjected to considerable dimensional changes during switching on and off. In the heating stage, the whole graphite structure of the reactor core and floor expands. In order to avoid arising constraining forces, sufficiently large expansion spaces must be allowed for furthermore restoring forces must be present to close the gaps again in the cooling phase. These restoring forces must be permanently present to prevent loosening of the core cuits amongst one another and thus uncontrollable relative movement. Spring elements are not suitable due to fast fatigue as a result of high temperatures and radiation exposure. It is suggested to have the floor elements supported on rollers whose rolling planes are downwards inclined to a fixed point for support. The construction is described in detail by means of drawings. (GL) [de

  20. No bulging of floor heating pipes to be expected in case of incomplete floor plastering

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U

    1983-02-01

    According to advertising slogans floor heating pipes are said to be damaged prematurely by bulges if they are not completely surrounded by flooring plaster. The author has thoroughly dealt with this problem and made the respective measurements. He found out that there are so few bulges occurring that they cannot lead to damages.

  1. Thin type inverter for machine-room-less elevator; Machine roomless elevator yo usugata inverter

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-01-10

    In the elevator industry, a machine-room-less elevator, which does not necessitate a machine room usually installed on the roof, has come into the spotlight in the domain of low and intermediate speed elevators. The lack of a machine room, however, will necessarily limit the space for the installation of the traction motor and control panel. Fuji Electric Co., Ltd., in order to properly cope with the situation, has developed in cooperation with Fujitec Co., Ltd., a very thin type inverter installable on an elevator hall floor. The inverter, based on Fuji Electric's high-performance vector control inverter FRENIC5000VG5, is as thin as 100mm, and is available in three series up to 11kW. For the embodiment of such a thin structure, a cooling structure of Fuji Electric's own is employed, and prudence is exercised as required at many locations so that maintainability will not be impaired throughout the very thin control panel design. (translated by NEDO)

  2. Recognition and Management of Nonrelaxing Pelvic Floor Dysfunction

    OpenAIRE

    Faubion, Stephanie S.; Shuster, Lynne T.; Bharucha, Adil E.

    2012-01-01

    Nonrelaxing pelvic floor dysfunction is not widely recognized. Unlike in pelvic floor disorders caused by relaxed muscles (eg, pelvic organ prolapse or urinary incontinence, both of which often are identified readily), women affected by nonrelaxing pelvic floor dysfunction may present with a broad range of nonspecific symptoms. These may include pain and problems with defecation, urination, and sexual function, which require relaxation and coordination of pelvic floor muscles and urinary and ...

  3. Floor-Fractured Craters through Machine Learning Methods

    Science.gov (United States)

    Thorey, C.

    2015-12-01

    Floor-fractured craters are impact craters that have undergone post impact deformations. They are characterized by shallow floors with a plate-like or convex appearance, wide floor moats, and radial, concentric, and polygonal floor-fractures. While the origin of these deformations has long been debated, it is now generally accepted that they are the result of the emplacement of shallow magmatic intrusions below their floor. These craters thus constitute an efficient tool to probe the importance of intrusive magmatism from the lunar surface. The most recent catalog of lunar-floor fractured craters references about 200 of them, mainly located around the lunar maria Herein, we will discuss the possibility of using machine learning algorithms to try to detect new floor-fractured craters on the Moon among the 60000 craters referenced in the most recent catalogs. In particular, we will use the gravity field provided by the Gravity Recovery and Interior Laboratory (GRAIL) mission, and the topographic dataset obtained from the Lunar Orbiter Laser Altimeter (LOLA) instrument to design a set of representative features for each crater. We will then discuss the possibility to design a binary supervised classifier, based on these features, to discriminate between the presence or absence of crater-centered intrusion below a specific crater. First predictions from different classifier in terms of their accuracy and uncertainty will be presented.

  4. Compliant flooring to prevent fall-related injuries: a scoping review protocol.

    Science.gov (United States)

    Lachance, Chantelle C; Jurkowski, Michal P; Dymarz, Ania C; Mackey, Dawn C

    2016-08-16

    Fall-related injuries can have serious consequences for older adults, including increased risk of dependence in daily activities and mortality. Compliant flooring is a passive intervention that may reduce the incidence and severity of fall-related injuries in healthcare settings, including acute and long-term care, but few sites have implemented compliant flooring, in part because synthesised evidence about key performance aspects has not been available. We will conduct a scoping review to address the question: what is presented about the biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety associated with compliant flooring systems that aim to prevent fall-related injuries? We will conduct a comprehensive and systematic literature search of academic databases (AgeLine, CINAHL, EBM Reviews, MEDLINE (Ovid), SportDiscus and Web of Science) and grey literature (clinical trial registries, theses/dissertations, abstracts/conference proceedings and relevant websites). 2 team members will independently screen records (first titles and abstracts, then full text) and extract data from included records. Numerical and narrative analyses will be presented by theme (biomechanical efficacy, clinical effectiveness, cost-effectiveness, workplace safety). This scoping review responds to the information needs of healthcare decision-makers tasked with preventing fall-related injuries. This review will summarise evidence about compliant flooring as a potential intervention for preventing fall-related injuries in older adults and identify gaps in evidence and new avenues for research. Results will be especially useful in long-term care, but also applicable in acute care, assisted living and home care. We will disseminate the review's findings via open-access publications, conference presentations, a webinar, a Stakeholder Symposium and a Knowledge-to-Action Report. Published by the BMJ Publishing Group Limited. For permission to use (where not

  5. Pushover, Response Spectrum and Time History Analyses of Safe Rooms in a Poor Performance Masonry Building

    International Nuclear Information System (INIS)

    Mazloom, M.

    2008-01-01

    The idea of safe room has been developed for decreasing the earthquake casualties in masonry buildings. The information obtained from the previous ground motions occurring in seismic zones expresses the lack of enough safety of these buildings against earthquakes. For this reason, an attempt has been made to create some safe areas inside the existing masonry buildings, which are called safe rooms. The practical method for making these safe areas is to install some prefabricated steel frames in some parts of the existing structure. These frames do not carry any service loads before an earthquake. However, if a devastating earthquake happens and the load bearing walls of the building are destroyed, some parts of the floors, which are in the safe areas, will fall on the roof of the installed frames and the occupants who have sheltered there will survive. This paper presents the performance of these frames located in a destroying three storey masonry building with favorable conclusions. In fact, the experimental pushover diagram of the safe room located at the ground-floor level of this building is compared with the analytical results and it is concluded that pushover analysis is a good method for seismic performance evaluation of safe rooms. For time history analysis the 1940 El Centro, the 2003 Bam, and the 1990 Manjil earthquake records with the maximum peak accelerations of 0.35g were utilized. Also the design spectrum of Iranian Standard No. 2800-05 for the ground kind 2 is used for response spectrum analysis. The results of time history, response spectrum and pushover analyses show that the strength and displacement capacity of the steel frames are adequate to accommodate the distortions generated by seismic loads and aftershocks properly

  6. Comparison of panoramic radiograph with cone-beam computed tomography in assessment of maxillary sinus floor and nasal floor

    Directory of Open Access Journals (Sweden)

    Vijay Kumar Bokkasam

    2015-01-01

    Full Text Available Introduction: Panoramic radiograph is frequently prescribed by dentists for implant planning and, hence, accurate assessment of anatomical structures in panoramic radiograph is of utmost importance. Aims: The aim of the present study is to know the accuracy of panoramic radiograph in assessment of relationship between maxillary sinus floor and posterior teeth roots, and the distance from alveolar crest to nasal floor by comparing it with that of cone-beam computed tomographic (CBCT image. Materials and Methods: Panoramic and CBCT images of 30 patients were analyzed. The topographic relationship of each root of posterior teeth to the maxillary sinus floor was evaluated and classified into three classes. The distance from the peak point on maxillary alveolar crest to nasal floor was measured in panoramic radiograph as well as in CBCT image. All the measurements were made by built-in measurement tools. Results: Class 1 roots in panoramic radiograph showed high agreement (86% with CBCT image, followed by class 0 (76%. There was a significant difference in the measurements of alveolar bone height (ABH in the nasal floor region with a P value of 0.018. Conclusion: Panoramic radiograph is reliable in assessment of nasal floor and maxillary sinus, provided position of the patient, distortion, and the inherent magnification factor are taken into consideration.

  7. Effect of thermal conductivities of shape stabilized PCM on under-floor heating system

    International Nuclear Information System (INIS)

    Cheng, Wenlong; Xie, Biao; Zhang, Rongming; Xu, Zhiming; Xia, Yuting

    2015-01-01

    Highlights: • HCE-SSPCM was prepared and used in under-floor heating system. • Enhancing thermal conductivity improved the efficiency of energy and space. • Too high thermal conductivity over a range was meaningless. • The economic benefits of the phase change energy storage system were the best. - Abstract: A kind of heat conduction-enhanced shape-stabilized PCM (HCE-SSPCM) was utilized in the under-floor heating system for house heating in winter. This system charges heat by using cheap nighttime electricity and provides heating needs throughout all day. The effect of thermal conductivity of the PCM on energy savings and economic benefits of the system were theoretically and experimentally studied. HCE-SSPCM plates, made of (solid paraffin + liquid paraffin)/high density polyethylene/expanded graphite, were introduced to a test room with under-floor heating system. And the operating characteristics of the system were compared with that of the non-phase change energy storage system and the conventional air conditioning system. The results showed that enhancing the thermal conductivity of PCM in a certain range could significantly improve the energy efficiency of the heating system and reduce the thickness of thermal insulating materials. But the improving effect was not obvious when the thermal conductivity was beyond 1.0 W/m K. The phase change energy storage system had a comfortable temperature environment and the best economic benefits among the three different heating types especially when the ratio of peak-valley electric price was high. Therefore, increasing the thermal conductivity of SSPCM will be of great significance for house heating

  8. Imaging pelvic floor disorders. 2. rev. ed.

    International Nuclear Information System (INIS)

    Stoker, Jaap; Taylor, Stuart A.; DeLancey, John O.L.

    2008-01-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  9. Imaging pelvic floor disorders. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Amsterdam Univ. (Netherlands). Dept. of Radiology; Taylor, Stuart A. [University College Hospital, London (United Kingdom). Dept. of Specialist X-Ray; DeLancey, John O.L. (eds.) [Michigan Univ., Ann Arbor, MI (United States). L4000 Women' s Hospital

    2008-07-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  10. 78 FR 30329 - Multilayered Wood Flooring from China

    Science.gov (United States)

    2013-05-22

    ...)] Multilayered Wood Flooring from China AGENCY: United States International Trade Commission. ACTION: Notice of...-1179 (Final) concerning multilayered wood flooring (``MLWF'') from China. For further information... reconsider ``its decision not to investigate domestic producers of hardwood plywood used for flooring'' 2. to...

  11. Pelvic floor function during and after first pregnancy

    NARCIS (Netherlands)

    Brummen, H.J. van

    2006-01-01

    This study evaluated the effects the first pregnancy and childbirth on the pelvic floor. Pregnancy and vaginal delivery can negatively affect pelvic floor function. Micturition symptoms, defecation symptoms and sexual dysfunction are all signs of an impaired pelvic floor function. These symptoms are

  12. Gait of dairy cows on floors with different slipperiness.

    Science.gov (United States)

    Telezhenko, E; Magnusson, M; Bergsten, C

    2017-08-01

    This study assessed the slip resistance of different types of solid flooring in cattle housing using a range of technical tests and gait analysis. Dynamic and static coefficient of friction, skid resistance, and abrasiveness were tested on concrete flooring with a smooth finish, a grooved pattern, or a tamped pattern, acid-resistant mastic asphalt, soft rubber mats, and a worn slatted concrete floor. Coefficients of friction and skid resistance were tested under clean and slurry-soiled conditions. Linear kinematic variables were assessed in 40 cows with trackway measurements after the cows passed over the floors in a straight walk. All gait variables were assessed as deviations from those obtained on the slatted concrete floor, which was used as a baseline. The coefficient of friction tests divided the floors into 3 categories: concrete flooring, which had a low coefficient of friction (0.29-0.41); mastic asphalt flooring, which had medium values (0.38-0.45); and rubber mats, which had high values (0.49-0.57). The highest abrasion (g/10 m) was on the asphalt flooring (4.48), and the concrete flooring with a tamped pattern had significantly higher abrasiveness (2.77) than the other concrete floors (1.26-1.60). Lowest values on the skid-resistance tests (dry/wet) were for smooth concrete (79/35) and mastic asphalt (65/47), especially with a slurry layer on the surface. Gait analysis mainly differentiated floors with higher friction and abrasion by longer strides and better tracking. Step asymmetry was lower on floors with high skid-resistance values. The most secure cow gait, in almost every aspect, was observed on soft rubber mats. Relationships between gait variables and physical floor characteristics ranged from average to weak (partial correlations 0.54-0.16). Thus, none of the physical characteristics alone was informative enough to characterize slip resistance. With reference to gait analysis, the abrasiveness of the hard surfaces was more informative than the

  13. Mapping of multi-floor buildings: A barometric approach

    DEFF Research Database (Denmark)

    Özkil, Ali Gürcan; Fan, Zhun; Xiao, Jizhong

    2011-01-01

    This paper presents a new method for mapping multi5floor buildings. The method combines laser range sensor for metric mapping and barometric pressure sensor for detecting floor transitions and map segmentation. We exploit the fact that the barometric pressure is a function of the elevation......, and it varies between different floors. The method is tested with a real robot in a typical indoor environment, and the results show that physically consistent multi5floor representations are achievable....

  14. Some Passive Damping Sources on Flooring Systems besides the TMD

    DEFF Research Database (Denmark)

    Pedersen, Lars

    2010-01-01

    Impulsive loads and walking loads can generate problematic structural vibrations in flooring-systems. Measures that may be taken to mitigate the problem would often be to consider the implementation of a tuned mass damper or even more advanced vibration control technologies; this in order to add...... damping to the structure. Basically also passive humans on a floor act as a damping source, but it also turns out from doing system identification tests with a floor strip that a quite simple set-up installed on the floor (cheap and readily at hand) might do a good job in terms of reducing vertical floor...... vibrations for some floors. The paper describes the tests with the floor strip, and the results, in terms of dynamic floor behaviour, are compared with what would be expected had the floor instead been equipped with a tuned mass damper....

  15. Life cycle inventory of manufacturing prefinished engineered wood flooring in eastern U.S. with comparison to solid strip wood flooring

    Science.gov (United States)

    Richard D. Bergman; Scott A. Bowe

    2011-01-01

    Building products have come under increased scrutiny because of environmental impacts from their manufacture. Our study followed the life cycle inventory approach for prefinished engineered wood flooring in the eastern US and compared the results with those of solid strip wood flooring. Our study surveyed five engineered wood flooring manufacturers in the eastern US....

  16. Experimental Verification of an Instrument to Test Flooring Materials

    Science.gov (United States)

    Philip, Rony; Löfgren, Hans, Dr

    2018-02-01

    The focus of this work is to validate the fluid model with different flooring materials and the measurements of an instrument to test flooring materials and its force attenuating capabilities using mathematical models to describe the signature and coefficients of the floor. The main contribution of the present work focus on the development of a mathematical fluid model for floors. The aim of the thesis was to analyze, compare different floor materials and to study the linear dynamics of falling impacts on floors. The impact of the hammer during a fall is captured by an accelerometer and response is collected using a picoscope. The collected data was analyzed using matlab least square method which is coded as per the fluid model. The finding from this thesis showed that the fluid model works with more elastic model but it doesn’t work for rigid materials like wood. The importance of parameters like velocity, mass, energy loss and other coefficients of floor which influences the model during the impact of falling on floors were identified and a standardized testing method was set.

  17. Patients with Pelvic Floor Muscle Spasm Have a Superior Response to Pelvic Floor Physical Therapy at Specialized Centers.

    Science.gov (United States)

    Polackwich, Alan Scott; Li, Jianbo; Shoskes, Daniel A

    2015-10-01

    Chronic prostatitis/chronic pelvic pain syndrome is a common condition that often requires multimodal therapy. Patients with chronic pelvic pain syndrome have a high incidence of pelvic floor spasm, which can be treated with pelvic floor physical therapy. However, this is a specialized skill. We compared outcomes of pelvic floor physical therapy as part of multimodal therapy in patients with chronic pelvic pain syndrome between those treated at our institution and elsewhere. We identified patients from our chronic pelvic pain syndrome registry with pelvic floor spasm who were seen between 2010 and 2014 for more than 1 visit. Patient phenotype was assessed with the UPOINT system and symptom severity was determined by the National Institutes of Health CPSI. A 6-point decrease in CPSI was used to define patient improvement. A total of 82 patients fit the study criteria. Mean age was 41.6 years (range 19 to 75) and median symptom duration was 24 months (range 3 to 240). Mean CPSI was 26.8 (range 10 to 41), the median number of positive UPOINT domains was 3 (range 1 to 6) and 27 patients (32.9%) were treated locally. At followup 9 patients had refused pelvic floor physical therapy, and 24 and 48 had undergone pelvic floor physical therapy elsewhere and at CCF, respectively. The mean change in CPSI was 1.11 ± 4.1 in patients who refused, -3.46 ± 6.7 in those treated elsewhere and -11.3 ± 7.0 in those treated at CCF (p physical therapy at CCF (OR 4.23, p = 0.002) and symptom duration (OR 0.52, p = 0.03) predicted improvement. Pelvic floor physical therapy can be effective for chronic pelvic pain syndrome in patients with pelvic floor spasm. However, the outcome depends on specialty training and experience of therapists. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Investigation of Floor Surface Finishes for Optimal Slip Resistance Performance

    Directory of Open Access Journals (Sweden)

    In-Ju Kim

    2018-03-01

    Full Text Available Background: Increasing the slip resistance of floor surfaces would be desirable, but there is a lack of evidence on whether traction properties are linearly correlated with the topographic features of the floor surfaces or what scales of surface roughness are required to effectively control the slipperiness of floors. Objective: This study expands on earlier findings on the effects of floor surface finishes against slip resistance performance and determines the operative ranges of floor surface roughness for optimal slip resistance controls under different risk levels of walking environments. Methods: Dynamic friction tests were conducted among three shoes and nine floor specimens under wet and oily environments and compared with a soapy environment. Results: The test results showed the significant effects of floor surface roughness on slip resistance performance against all the lubricated environments. Compared with the floor-type effect, the shoe-type effect on slip resistance performance was insignificant against the highly polluted environments. The study outcomes also indicated that the oily environment required rougher surface finishes than the wet and soapy ones in their lower boundary ranges of floor surface roughness. Conclusion: The results of this study with previous findings confirm that floor surface finishes require different levels of surface coarseness for different types of environmental conditions to effectively manage slippery walking environments. Collected data on operative ranges of floor surface roughness seem to be a valuable tool to develop practical design information and standards for floor surface finishes to efficiently prevent pedestrian fall incidents. Keywords: floor surface finishes, operational levels of floor surface roughness, slip resistance, wet, soapy and oily environments

  19. An architecture for agile shop floor control systems

    DEFF Research Database (Denmark)

    Langer, Gilad; Alting, Leo

    2000-01-01

    as shop floor control. This paper presents the Holonic Multi-cell Control System (HoMuCS) architecture that allows for design and development of holonic shop floor control systems. The HoMuCS is a shop floor control system which is sometimes referred to as a manufacturing execution system...

  20. Comfort analysis of lightweight floor system

    NARCIS (Netherlands)

    Zegers, S.F.A.J.G.; Herwijnen, van F.; Randall, B.

    2007-01-01

    During the past 60 years, floor systems used in housing and office-buildings in the Netherlands were mostly made of concrete or other similar materials, These floor systems, which can be characterized as heavy, normally posed little problems concerning vibrations. In recent years, in light of

  1. Decontamination and decommissioning of the extraction chemical room at the West Valley Demonstration Project. Final topical report, December 1982-April 1984

    International Nuclear Information System (INIS)

    Phillips, E.C.

    1985-12-01

    The purpose of this report is to describe the preparation of a facility for use in decontaminating and decommissioning (D and D) extraction cells at the West Valley Demonstration Project (WVDP). In order to prepare such a facility, it was necessary to decontaminate, decommission and equip the Extraction Chemical Room (XCR) at the WVDP. This report describes the D and D of the XCR from a radioactively contaminated condition to an essentially shirt sleeve environment. Also included is a description of the changes made to the XCR for use in the D and D of the extraction cells which are located beneath the floor of the XCR. In the XCR prior to D and D, radiological surveys indicated a maximum radiation field of 5 mrad/hr, due to sources internal to the room, and 20,000 dpm beta/100 cm 2 surface contamination. A radiation source external to the XCR caused a hot spot with a 9 mrad/hr exposure rate inside the XCR. The D and D of the XCR, located on the fifth floor elevation 48.8 m of the reprocessing plant at the WVDP, has been completed. D and D operations included removal of piping, tanks, supports, and equipment to provide a clean work area of about 278.7 m 2 and 5.2 m high. Subsequent to the removal of piping and equipment, a new floor was installed in part of the room and equipment for use in the D and D of the extraction cells was added. The equipment included a large containment tent over the extraction cell hatches, a jib crane, two gantries, a monorail crane, an air transporter, and a temporary ventilation system. D and D operations in the XCR were initiated in December 1982 and the completed facility was available for use in February 1984

  2. Floor Vibrations - as Induced and Reduced by Humans

    DEFF Research Database (Denmark)

    Pedersen, Lars

    . As for dynamic loads focus is placed on heel impact excitation and actions of jumping people causing floor vibrations. As for interaction between stationary humans and the vibrating floor focus is on modelling humans as oscillating spring-mass-damper systems attached to the floor rather than as simple added mass...

  3. Decontamination and renovation of the Master/Slave Manipulator Repair Shop and the Chemical Crane Room at the West Valley Demonstration Project. Final topical report, June 1982-June 1983

    International Nuclear Information System (INIS)

    Phillips, E.C.; Golden, M.P.

    1986-01-01

    This report describes the decontamination and renovation of the Master/Slave Manipulator Repair Shop (MSMRS) and the Chemical Crane Room (CCR) at the WVDP from radioactively contaminated conditions to essentially shirt sleeve environments. In both cases, subsequent use recontaminated the rooms. Before decontamination, general exposure rates as high as 20 mrad/hr and surface contamination as high as 10 5 dpm/100 cm 2 were measured in the MSMRS, while general exposure rates in the CCR were 50 to 100 mrad/hr with hot spots as high as 2000 mrad/hr. Smearable levels on the floor in each room were in the range of 10 5 to 10 6 dpm per 100/cm 2 . Respiratory protection was mandatory for entry into the CCR. The MSMRS, located at the north end of the Process Building on ground elevation, is needed for the refurbishment of plant manipulators and other equipment. The MSMRS has been decontaminated and renovated as follows: all tools, equipment and furnishings were removed, the walls were stripped and repainted, and the contaminated concrete floor was removed and disposal of as low-level waste. A new concrete floor was poured and a stainless steel liner covering the entire floor and extending 45.7 cm up the walls was added to provide the WVDP with a shop facility that can be easily decontaminated. Decontamination of the MSMRS has been completed and the facility is available for service. The CCR, located at the north end of the Chemical Process Cell (CPC) is for the storage and servicing of two bridge cranes used in the CPC. Decontamination and exposure reduction in the CCR has been completed using vacuum cleaning, damp wipe down, and surface grinding followed by shielding and painting

  4. Electrotechnical installations. Transformer stations. Construction; transformer rooms. Elektrotechnische Anlagen. Transformatorenstationen. Bauliche Ausfuehrung; Raeume fuer Transformatoren

    Energy Technology Data Exchange (ETDEWEB)

    1976-05-01

    The data sheet to standardize the construction of transformer rooms for stationary transformers and takes into account the replacement of transformers by units made by different manufacturers. It contains information about the position, dimensions, load assumptions, construction of ceilings, walls and floors, cable routes, electric installations for lighting and ventilation systems, windows and doors, venting, paint and surface protection coatings, arrangement and design of oil catch pans, and calculation of the venting cross sections. Pertinent VDE rules are listed.

  5. Flooring-systems and their interaction with furniture and humans

    DEFF Research Database (Denmark)

    Frier, Christian; Pedersen, Lars; Andersen, Lars Vabbersgaard

    2017-01-01

    Flooring-system designs may be sensitive in terms of their vibrational performance due the risk that serviceability-limit-state problems may be encountered. For evaluating the vibrational performance of a flooring system at the design stage, decisions must be made by the engineer in charge...... of computations. Passive humans and/or furniture are often present on a floor. Typically, these masses and their way of interacting with the floor mass are ignored in predictions of vibrational behaviour of the flooring system. Utilizing a shell finite-element model, the paper explores and quantifies how non......-structural mass can influence central parameters describing the dynamic behaviour of the flooring system with focus on elevated non-structural mass. © 2017 The Authors. Published by Elsevier Ltd....

  6. Moisture supply in Danish single-family houses – the influence of occupant behaviour and type of room

    DEFF Research Database (Denmark)

    Møller, Eva B.; Hansen, Ernst Jan de Place

    2017-01-01

    According to ISO 13788, the internal moisture supply in dwellings can be described by humidity classes defined by outdoor temperature, occupancy and ventilation. Hygrothermal measurements in indoor air in 500 Danish single-family houses were made to investigate if this corresponds with reality....... The study focuses on the dependency of number and age of occupants, occupants’ time spent in the house, square meters living space, ventilation habits and type of room. Moisture supply depends on the type of room; bathroom, basement and living room have the highest values. None of the other parameters seems...

  7. Development of floor design response spectra for seismic design of floor-supported equipment or components, Revision 1, February 1978

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This guide presents an acceptable method for developing two horizontal and one vertical floor design response spectra at various floor or other equipment-support locations from the time-history motions resulting from the dynamic analysis of the supporting structure. These floor design response spectra are used in the dynamic analysis of systems or equipment supported at various locations of the supporting structure. Consulation has been provided by the Advisory Committee on Reactor Safeguards

  8. Decontamination of polyvinylchloride- and rubber type flooring

    International Nuclear Information System (INIS)

    Kunze, S.

    1975-01-01

    These types, fabricated by mixing of the basic components, showed no relation between content of fillers and decontamination results. Decontamination results are partly poorer, if the flooring contains a high concentration of the filler, especially if the latter consists mainly of hydrophilic materials. The coloring of the floorings seems to have no influence on the decontamination but floorings with clearly separated patterns can not be recommended for nuclear facilities. Fabricated by chemical reactions between polymeres, vulcanization materials and fillers, the decontamination results depend definitely from the proper choice of the filler. Flooring types, containing lampblack, graphite, kaoline, barium sulfate and titanium oxide are easy to decontamine. Again, increasing contents of hydrophilic filler cause a fall off in the decontamination results. (orig.) [de

  9. Effect of space allowance and floor type on performance, welfare and physiological measurements of finishing beef heifers.

    Science.gov (United States)

    Keane, M P; McGee, M; O'Riordan, E G; Kelly, A K; Earley, B

    2017-12-01

    Accommodating cattle indoors during the winter is widely practiced throughout Europe. There is currently no legislation surrounding the space allowance and floor type that should be provided to cattle during this time, however, concerns have been raised regarding the type of housing systems currently in use. The objective of the study was to investigate the effect of space allowance and floor type on performance and welfare of finishing beef heifers. Continental crossbred heifers (n=240: mean initial live; weight, 504 (SD 35.8) kg) were blocked by breed, weight and age and randomly assigned to one of four treatments; (i) 3.0 m2, (ii) 4.5 m2 and (iii) 6.0 m2 space allowance per animal on a fully slatted concrete floor and (iv) 6.0 m2 space allowance per animal on a straw-bedded floor, for 105 days. Heifers were offered a total mixed ration ad libitum. Dry matter intake was recorded on a pen basis and refusals were weighed back twice weekly. Heifers were weighed, dirt scored and blood sampled every 3 weeks. Whole blood was analysed for complete cell counts and serum samples were assayed for metabolite concentrations. Behaviour was recorded continuously using IR cameras from days 70 to 87. Heifers' hooves were inspected for lesions at the start of the study and again after slaughter. Post-slaughter, carcass weight, conformation and fat scores and hide weight were recorded. Heifers housed at 4.5 m2 had a greater average daily live weight gain (ADG) than those on both of the other concrete slat treatments; however, space allowance had no effect on carcass weight. Heifers accommodated on straw had a greater ADG (0.15 kg) (PSpace allowance and floor type had no effect on the number of hoof lesions gained or on any of the haematological or metabolic variables measured. It was concluded that increasing space allowance above 3.0 m2/animal on concrete slats was of no benefit to animal performance but it did improve animal cleanliness. Housing heifers on straw instead of

  10. A novel technique to optimise the length of a linear accelerator treatment room maze without compromising radiation protection.

    Science.gov (United States)

    Al-Affan, I A M; Evans, S C; Qutub, M; Hugtenburg, R P

    2018-03-01

    Simulations with the FLUktuierende KAskade (FLUKA) Monte Carlo code were used to establish the possibility of introducing lead to cover the existing concrete walls of a linear accelerator treatment room maze, in order to reduce the dose of the scattered photons at the maze entrance. In the present work, a pilot study performed at Singleton Hospital in Swansea was used to pioneer the use of lead sheets of various thicknesses to absorb scattered low energy photons in the maze. The dose reduction was considered to be due to the strong effect of the photoelectric interaction in lead resulting in attenuation of the back-scattered photons. Calculations using FLUKA with mono-energetic photons were used to represent the main components of the x-ray spectrum up to 10 MV. Mono-energetic photons were used to enable the study of the behaviour of each energy component from the associated interaction processes. The results showed that adding lead of 1 to 4 mm thickness to the walls and floor of the maze reduced the dose at the maze entrance by up to 80%. Subsequent scatter dose measurements performed at the maze entrance of an existing treatment room with lead sheet of 1.3 mm thickness added to the maze walls and floor supported the results from the simulations. The dose reduction at the maze entrance with the lead in place was up to 50%. The variation between simulation and measurement was attributed to the fact that insufficient lead was available to completely cover the maze walls and floor. This novel proposal of partly, or entirely, covering the maze walls with lead a few millimetres in thickness has implications for the design of linear accelerator treatment rooms since it has the potential to provide savings, in terms of space and costs, when an existing maze requires upgrading in an environment where space is limited and the maze length cannot be extended sufficiently to reduce the dose.

  11. Historical Cavern Floor Rise for All SPR Sites

    Energy Technology Data Exchange (ETDEWEB)

    Moriarty, Dylan Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-01

    The Strategic Petroleum Reserve (SPR) contains the largest supply is the largest stockpile of government-owned emergency crude oil in the world. The oil is stored in multiple salt caverns spread over four sites in Louisiana and Texas. Cavern infrastructure near the bottom of the cavern can be damaged from vertical floor movement. This report presents a comprehensive history of floor movements in each cavern. Most of the cavern floor rise rates ranged from 0.5-3.5 ft/yr, however, there were several caverns with much higher rise rates. BH103, BM106, and BH105 had the three highest rise rates. Information from this report will be used to better predict future vertical floor movements and optimally place cavern infrastructure. The reasons for floor rise are not entirely understood and should be investigated.

  12. Association between preterm labour and pelvic floor muscle function.

    Science.gov (United States)

    Aran, Turhan; Pekgöz, Ipek; Bozkaya, Hasan; Osmanagaoglu, Mehmet A

    2018-03-23

    We hypothesised that the pressure on the cervix increases with advancing gestation and it may lead to a cervical shortening and cause preterm labour in women with weak pelvic floor muscles. The aim of this prospective study was to measure vaginal resting pressure and pelvic floor muscle strength in the first trimester of pregnancy and to investigate their effects on labour. A study was conducted on the pregnant women with a low risk for preterm birth. The pelvic floor muscle strength and vaginal resting pressure were assessed in 320 pregnant women at their first trimester with a vaginal pressure measurement device. Fifty-two pregnant women were hospitalised for tocolytic therapy because of spontaneous preterm labour. Thirty-two of them (10.2%) had a preterm delivery despite the tocolytic therapy. Both the vaginal resting pressure (p = .009, 95%CI: 0.8; 5.9) and the pelvic floor muscle strength (p = .01, 95%CI: 3.5; 13.1) were significantly lower in the women with a preterm labour. Impact statement What is already known on this subject? The pelvic floor muscles have an essential role in continence and provide support to the pelvic organs. They also have an impact on labour. The pelvic floor muscles should distend to allow the passage of the foetus during labour. The rotation and flexion of the foetal head is due to the pelvic floor resistance. The effect of a vaginal birth on the pelvic floor's function is readily understood. On the other hand, the effect of the pelvic floor muscle function on labour is still controversial. What do the results of this study add? This prospective study showed that there is a negative association between the pelvic floor muscle strength and preterm labour. This is the first clinical study indicating that weak pelvic floor muscles may cause a preterm labour. What are the implications of these findings for clinical practice and/or further research? Pelvic floor physical therapy may be an alternative preventive strategy to reduce

  13. Biomechanics of the pelvic floor musculature

    NARCIS (Netherlands)

    Janda, S.

    2006-01-01

    The present thesis was motivated by two main goals. The first research goal of the thesis was to understand the complex biomechanical behaviour of the pelvic floor muscles. The second goal was to study the mechanism of the pelvic organ prolapse (genital prolapse). The pelvic floor in humans is a

  14. Thermal comfort and ventilation effectiveness in an office room with radiant floor cooling and displacement ventilation

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2016-01-01

    conditions, varying the nominal air change rate from 4.5h-1 down to 1.5h-1. Contaminant removal and mean-age-of-air measurements were performed to characterize the ventilation effectiveness and air velocity; air and operative temperature profiles were measured, together with thermal manikin equivalent...... temperatures, to evaluate the thermal environment. The combined system was able to achieve good ventilation effectiveness close to a heat source, so that in the occupant's breathing zone the ventilation effectiveness was significantly better than for ideal mixing, even at a nominal air change rate as low as 1......% at the highest nominal air change rate of 4.5h-1, even for an occupant sitting 1 meter in front of the supply diffuser, the local thermal discomfort occasioned by the excessive vertical temperature differences gives chilled ceilings the advantage over chilled floors for use with displacement ventilation....

  15. Motor cortical representation of the pelvic floor muscles.

    Science.gov (United States)

    Schrum, A; Wolff, S; van der Horst, C; Kuhtz-Buschbeck, J P

    2011-07-01

    Pelvic floor muscle training involves rhythmical voluntary contractions of the external urethral sphincter and ancillary pelvic floor muscles. The representation of these muscles in the motor cortex has not been located precisely and unambiguously. We used functional magnetic resonance imaging to determine brain activity during slow and fast pelvic floor contractions. Cerebral responses were recorded in 17 healthy male volunteers, 21 to 47 years old, with normal bladder control. Functional magnetic resonance imaging was performed during metronome paced slow (0.25 Hertz) and fast (0.7 Hertz) contractions of the pelvic floor that mimicked the interruption of voiding. To study the somatotopy of the cortical representations, flexion-extension movements of the right toes were performed as a control task. Functional magnetic resonance imaging during pelvic floor contractions detected activity of the supplementary motor area in the medial wall and of the midcingulate cortex, insula, posterior parietal cortex, putamen, thalamus, cerebellar vermis and upper ventral pons. There were no significant differences in activation between slow and fast contractions. Toe movements involved significantly stronger activity of the paracentral lobule (ie the medial primary motor cortex) than did the pelvic floor contractions. Otherwise the areas active during pelvic floor and leg muscle contractions overlapped considerably. The motor cortical representation of pelvic floor muscles is located mostly in the supplementary motor area. It extends further ventrally and anteriorly than the representation of distal leg muscles. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. 9 CFR 91.26 - Concrete flooring.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Concrete flooring. 91.26 Section 91.26... LIVESTOCK FOR EXPORTATION Inspection of Vessels and Accommodations § 91.26 Concrete flooring. (a) Pens aboard an ocean vessel shall have a 3 inch concrete pavement, proportioned and mixed to give 2000 psi...

  17. Surgical reconstruction of pelvic floor descent: anatomic and functional aspects.

    Science.gov (United States)

    Wagenlehner, F M E; Bschleipfer, T; Liedl, B; Gunnemann, A; Petros, P; Weidner, W

    2010-01-01

    The human pelvic floor is a complex structure and pelvic floor dysfunction is seen frequently in females. This review focuses on the surgical reconstruction of the pelvic floor employing recent findings on functional anatomy. A selective literature research was performed by the authors. Pelvic floor activity is regulated by 3 main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor organs, bladder and rectum. A variety of symptoms can derive from pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, fecal incontinence, obstructive bowel disease syndrome and pelvic pain. These symptoms mainly derive, for different reasons, from laxity in the vagina or its supporting ligaments as a result of altered connective tissue. Pelvic floor reconstruction is nowadays driven by the concept that in case of pelvic floor symptoms, restoration of the anatomy will translate into restoration of the physiology and ultimately improve patients' symptoms. The surgical reconstruction of the anatomy is almost exclusively focused on the restoration of the lax pelvic floor ligaments. Exact preoperative identification of the anatomical lesions is necessary to allow for exact anatomical reconstruction with respect to the muscular forces of the pelvic floor. Copyright 2010 S. Karger AG, Basel.

  18. risk factors of active tuberculosis in people living with hiv/aids

    African Journals Online (AJOL)

    Abrham

    2011-07-02

    Jul 2, 2011 ... The objective of this study was to assess distal ... KEYWORDS: Active TB, HIV, risk factors, case control study, Southwest Ethiopia ... and Khat (stimulant plant from Chata Edulis), .... to live in a house made of a cement floor.

  19. Study of peak broadening effect in floor time histories

    International Nuclear Information System (INIS)

    Soni, R.S.; Kushwaha, H.S.; Mahajan, S.C.; Kakodkar, A.

    1996-01-01

    Seismic design of secondary systems such components and piping is usually carried out by using the floor motions at their support points. These floor motions can be in the form of Floor Response Spectra (FRS) or the Floor Time Histories (FTH). In order to account for the various uncertainties in generating these floor motions, these motions should be peak broadened and smoothened as per the regulatory codes. Presented here in this paper is the methodology to account for such peak broadening effect in the FTH. Results of this study have been compared with the FRS approach and various important conclusions have been arrived at based on the study

  20. Comparison of changes in the mobility of the pelvic floor muscle on during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction.

    Science.gov (United States)

    Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho

    2016-01-01

    [Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility was evaluated as the distance from the bladder base using ultrasound. [Results] According to exercise method, bridge exercise and abdominal curl-ups led to significantly different pelvic floor mobility. The pelvic floor muscle was elevated during the abdominal drawing-in maneuver and descended during maximal expiration. Finally, pelvic floor muscle mobility was greater during abdominal curl-up than during the bridge exercise. [Conclusion] According to these results, the abdominal drawing-in maneuver induced pelvic floor muscle contraction, and pelvic floor muscle contraction was greater during the abdominal curl-up than during the bridge exercise.

  1. FLOOR IDENTIFICATION WITH COMMERCIAL SMARTPHONES IN WIFI-BASED INDOOR LOCALIZATION SYSTEM

    Directory of Open Access Journals (Sweden)

    H. J. Ai

    2016-06-01

    Full Text Available In this paper, we utilize novel sensors built-in commercial smart devices to propose a schema which can identify floors with high accuracy and efficiency. This schema can be divided into two modules: floor identifying and floor change detection. Floor identifying module starts at initial phase of positioning, and responsible for determining which floor the positioning start. We have estimated two methods to identify initial floor based on K-Nearest Neighbors (KNN and BP Neural Network, respectively. In order to improve performance of KNN algorithm, we proposed a novel method based on weighting signal strength, which can identify floors robust and quickly. Floor change detection module turns on after entering into continues positioning procedure. In this module, sensors (such as accelerometer and barometer of smart devices are used to determine whether the user is going up and down stairs or taking an elevator. This method has fused different kinds of sensor data and can adapt various motion pattern of users. We conduct our experiment with mobile client on Android Phone (Nexus 5 at a four-floors building with an open area between the second and third floor. The results demonstrate that our scheme can achieve an accuracy of 99% to identify floor and 97% to detecting floor changes as a whole.

  2. The influence of flooring on environmental stressors: a study of three flooring materials in a hospital.

    Science.gov (United States)

    Harris, Debra D

    2015-01-01

    Three flooring materials, terrazzo, rubber, and carpet tile, in patient unit corridors were compared for absorption of sound, comfort, light reflectance, employee perceptions and preferences, and patient satisfaction. Environmental stressors, such as noise and ergonomic factors, effect healthcare workers and patients, contributing to increased fatigue, anxiety and stress, decreased productivity, and patient safety and satisfaction. A longitudinal comparative cohort study comparing three types of flooring assessed sound levels, healthcare worker responses, and patient Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) ratings over 42 weeks. A linear mixed model analysis was conducted to determine significant differences between the means for participant responses and objective sound meter data during all three phases of the study. A significant difference was found for sound levels between flooring type for equivalent continuous sound levels. Carpet tile performed better for sound attenuation by absorption, reducing sound levels 3.14 dBA. Preferences for flooring materials changed over the course of the study. The HCAHPS ratings aligned with the sound meter data showing that patients perceived the noise levels to be lower with carpet tiles, improving patient satisfaction ratings. Perceptions for healthcare staff and patients were aligned with the sound meter data. Carpet tile provides sound absorption that affects sound levels and influences occupant's perceptions of environmental factors that contribute to the quality of the indoor environment. Flooring that provides comfort underfoot, easy cleanability, and sound absorption influence healthcare worker job satisfaction and patient satisfaction with their patient experience. © The Author(s) 2015.

  3. Recognition and Management of Nonrelaxing Pelvic Floor Dysfunction

    Science.gov (United States)

    Faubion, Stephanie S.; Shuster, Lynne T.; Bharucha, Adil E.

    2012-01-01

    Nonrelaxing pelvic floor dysfunction is not widely recognized. Unlike in pelvic floor disorders caused by relaxed muscles (eg, pelvic organ prolapse or urinary incontinence, both of which often are identified readily), women affected by nonrelaxing pelvic floor dysfunction may present with a broad range of nonspecific symptoms. These may include pain and problems with defecation, urination, and sexual function, which require relaxation and coordination of pelvic floor muscles and urinary and anal sphincters. These symptoms may adversely affect quality of life. Focus on the global symptom complex, rather than the individual symptoms, may help the clinician identify the condition. The primary care provider is in a position to intervene early, efficiently, and effectively by (1) recognizing the range of symptoms that might suggest nonrelaxing pelvic floor dysfunction, (2) educating patients, (3) performing selective tests when needed to confirm the diagnosis, and (4) providing early referral for physical therapy. PMID:22305030

  4. Glazed Tiles as Floor Finish in Nigeria

    Directory of Open Access Journals (Sweden)

    Toyin Emmanuel AKINDE

    2013-09-01

    Full Text Available Tile is no doubt rich in antiquity; its primordial  show, came as mosaic with primary prospect in sacred floor finish before its oblivion, courtesy of, later consciousness towards wall finish in banquets, kitchens, toilets, restaurants and even bars. Today, its renaissance as floor finish is apparent in private and public architectural structures with prevalence in residential, recreational, commercial, governmental and other spaces. In Nigeria, the use of glazed tiles as floor finish became apparent, supposedly in mid-twentieth century; and has since, witnessed ever increasing demands from all sundry; a development that is nascent and has necessitated its mass  production locally with pockets of firms in the country. The latter however, is a resultant response to taste cum glazed tiles affordability, whose divergent sophistication in design, colour, size and shape is believed preferred to terrazzo, carpet and floor flex tile. Accessible as glazed tile and production is, in recent times; its dearth of a holistic literature in Nigeria is obvious. In the light of the latter, this paper examine glazed tiles as floor finish in Nigeria, its advent, usage, production, challenge, benefit and prospect with the hope of opening further frontier in discipline specifics.

  5. WOODEN FLOORING – BETWEEN PRESENT AND FUTURE

    Directory of Open Access Journals (Sweden)

    Ivan CISMARU

    2015-06-01

    Full Text Available The paper aims at presenting a systematization of the wood floors, both in terms of the areas of application, and in terms of the fastening solutions and structures in constructions. In this respect, an extensive bibliographic research was achieved, on the researchers’ preoccupations. Starting from the current situation and forecasting the future, from the point of view of the chances held by wooden flooring, in competition with other types of materials, we dare say the wooden flooring or the wood in combination with other materials are not likely to be eliminated from the “civil-engineering market”. The wood floors are likely to develop as an application, especially in the area of the “special floors”, specific to the indoor sports or social halls; and even for some industrial sectors, with strict operating conditions (elasticity, thermal insulation, soundproofing that cannot be provided by other types of materials or structures. Starting from this last observation, the paper also aims at submitting current opinions with respect to this type of floors, both in the light of the current databases and in the light of the future researches, to this end

  6. What Is Low Profile Access Flooring and Why More Businesses Need It

    OpenAIRE

    NetfloorUSA

    2017-01-01

    Low profile access flooring is being commonly used in a variety of businesses today. To understand why more businesses, need this type of flooring, it is essential that we take the time to first understand what is low profile flooring actually is. What Is Low Profile Access Flooring A low profile access floor is a floor that is designed to sit above the original concrete slab flooring installed in any home, business, or public building. The higher floor height creates a space between ...

  7. Polygons on Crater Floor

    Science.gov (United States)

    2003-01-01

    MGS MOC Release No. MOC2-357, 11 May 2003This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) picture shows a pattern of polygons on the floor of a northern plains impact crater. These landforms are common on crater floors at high latitudes on Mars. Similar polygons occur in the arctic and antarctic regions of Earth, where they indicate the presence and freeze-thaw cycling of ground ice. Whether the polygons on Mars also indicate water ice in the ground is uncertain. The image is located in a crater at 64.8oN, 292.7oW. Sunlight illuminates the scene from the lower left.

  8. 17 CFR 240.11a-1 - Regulation of floor trading.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Regulation of floor trading... Securities Exchange Act of 1934 Adoption of Floor Trading Regulation (rule 11a-1) § 240.11a-1 Regulation of floor trading. (a) No member of a national securities exchange, while on the floor of such exchange...

  9. Physical distribution of oak strip flooring 1969

    Science.gov (United States)

    William C. Miller; William C. Miller

    1971-01-01

    As an aid to the marketing of oak strip flooring, a study was made of the distribution process for this product, from manufacture to consumer-where the flooring came from, where it went, how much was shipped, and who handled it.

  10. Pelvic floor muscle training as a persistent nursing intervention: Effect on delivery outcome and pelvic floor myodynamia

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2014-03-01

    Conclusion: Persistent nursing intervention for pregnant/postpartum women helped to shorten the second stage of labour and contributed to the recovery of postpartum pelvic floor myodynamia. The influence of this intervention on the delivery mode, and rates of episiotomy and perineal laceration remains unknown. Medical staff should strengthen health education programmes that involve pelvic floor functional rehabilitation.

  11. 24 CFR 35.110 - Definitions.

    Science.gov (United States)

    2010-04-01

    ..., such as a bedroom wall, an exterior window sill, a baseboard in a living room, a kitchen floor, an... meet applicable local rehabilitation standards; (2) Costs to make essential improvements, including... repair or replace major housing systems in danger of failure; and (3) Costs of non-essential improvements...

  12. Assessment of the effect of pelvic floor exercises on pelvic floor muscle strength using ultrasonography in patients with urinary incontinence: a prospective randomized controlled trial

    OpenAIRE

    Tosun, Ozge Celiker; Solmaz, Ulas; Ekin, Atalay; Tosun, Gokhan; Gezer, Cenk; Ergenoglu, Ahmet Mete; Yeniel, Ahmet Ozgur; Mat, Emre; Malkoc, Mehtap; Askar, Niyazi

    2016-01-01

    [Purpose] The aim of this study was to evaluate whether the effect of pelvic floor exercises on pelvic floor muscle strength could be detected via ultrasonography in patients with urinary incontinence. [Subjects and Methods] Of 282 incontinent patients, 116 participated in the study and were randomly divided into a pelvic floor muscle training (n=65) group or control group (n=51). The pelvic floor muscle training group was given pelvic floor exercise training for 12 weeks. Both groups were ev...

  13. Air gun near the sea floor as shear-wave source?

    NARCIS (Netherlands)

    Drijkoningen, G.G.; Dieulangard, D.; Holicki, M.E.

    2015-01-01

    The feasibility of using an air gun near the sea floor as shear-wave source has been investigated. With an air gun near the sea floor, an evanescent P-wave in the water becomes a propagating S-wave in the sea floor, such that it seems that a pure shear-wave source has been used at the sea floor.

  14. Physiological and subjective responses in the elderly when using floor heating and air conditioning systems.

    Science.gov (United States)

    Hashiguchi, Nobuko; Tochihara, Yutaka; Ohnaka, Tadakatsu; Tsuchida, Chiaki; Otsuki, Tamio

    2004-11-01

    The purpose of this study was to investigate the effects of a floor heating and air conditioning system on thermal responses of the elderly. Eight elderly men and eight university students sat for 90 minutes in a chair under the following 3 conditions: air conditioning system (A), floor heating system (F) and no heating system (C). The air temperature of sitting head height for condition A was 25 degrees C, and the maximum difference in vertical air temperature was 4 degrees C. The air and floor temperature for condition F were 21 and 29 degrees C, respectively. The air temperature for condition C was 15 degrees C. There were no significant differences in rectal temperature and mean skin temperature between condition A and F. Systolic blood pressure of the elderly men in condition C significantly increased compared to those in condition A and F. No significant differences in systolic blood pressure between condition A and F were found. The percentage of subjects who felt comfortable under condition F was higher than that of those under condition A in both age groups, though the differences between condition F and A was not significant. Relationships between thermal comfort and peripheral (e.g., instep, calf, hand) skin temperature, and the relationship between thermal comfort and leg thermal sensation were significant for both age groups. However, the back and chest skin temperature and back thermal sensation for the elderly, in contrast to that for the young, was not significantly related to thermal comfort. These findings suggested that thermal responses and physiological strain using the floor heating system did not significantly differ from that using the air conditioning system, regardless of the subject age and despite the fact that the air temperature with the floor heating system was lower. An increase in BP for elderly was observed under the condition in which the air temperature was 15 degrees C, and it was suggested that it was necessary for the elderly

  15. Ventilation efficiency in a low-energy dwelling setting – a parameter study for larger rooms

    NARCIS (Netherlands)

    Dijkstra, D.; Loomans, M.G.L.C.; Hensen, J.L.M.; Cremers, B.E. (Bart)

    2016-01-01

    Mechanical balanced ventilation systems typically is applied in new and renovated dwellings in The Netherlands. The application assumes an adequate ventilation efficiency but this has not been confirmed for larger rooms (e.g. living rooms with kitchen attached). This study investigates ventilation

  16. Dermoid cyst in the mouth floor

    International Nuclear Information System (INIS)

    Portelles Masso, Ayelen Maria; Torres Inniguez, Ailin Tamara.

    2010-01-01

    The Dermoid cyst account for the 0.01 % of all cysts of buccal cavity. Its more frequent location is in the mouth floor. This is the case of a female patient aged 19 who approximately 7 years noted an increase of volume under tongue growing gradually and noting outside face and the discomfort at to speak and to chew. Complementary studies were conducted and under general anesthesia a surgical exeresis was carried out by intrabuccal approach achieving excellent esthetic and functional results. Histopathologic diagnosis matched with a dermoid cyst of mouth floor. Patient has not lesion recurrence after three years after operation. We conclude that the Dermoid cyst of mouth floor appear as benign tumor of middle line. The intrabuccal exeresis demonstrates esthetic and functional benefits. (author)

  17. Improving the cleaning procedure to make kitchen floors less slippery.

    Science.gov (United States)

    Quirion, F; Poirier, P; Lehane, P

    2008-12-01

    This investigation shows that, in most cases, the floor cleaning procedure of typical restaurants could be improved, resulting in a better cleaning efficiency and a better floor friction. This simple approach could help reduce slips and falls in the workplace. Food safety officers visited ten European style restaurants in the London Borough of Bromley (UK) to identify their floor cleaning procedure in terms of the cleaning method, the concentration and type of floor cleaner and the temperature of the wash water. For all 10 restaurants visited, the cleaning method was damp mopping. Degreasers were used in three sites while neutral floor cleaners were used in seven sites. Typically, the degreasers were over diluted and the neutrals were overdosed. The wash water temperature ranged from 10 to 72 degrees C. The on-site cleaning procedures were repeated in the laboratory for the removal of olive oil from new and sealed quarry tiles, fouled and worn quarry tiles and new porcelain tiles. It is found that in 24 out of 30 cases, cleaning efficiency can be improved by simple changes in the floor cleaning procedure and that these changes result in a significant improvement of the floor friction. The nature of the improved floor cleaning procedure depends on the flooring type. New and properly sealed flooring tiles can be cleaned using damp mopping with a degreaser diluted as recommended by the manufacturer in warm or hot water (24 to 50 degrees C). But as the tiles become worn and fouled, a more aggressive floor cleaning is required such as two-step mopping with a degreaser diluted as recommended by the manufacturer in warm water (24 degrees C).

  18. Nondestructive structural evaluation of wood floor systems with a vibration technique.

    Science.gov (United States)

    Xiping Wang; Robert J. Ross; Lawrence Andrew Soltis

    2002-01-01

    The objective of this study was to determine if transverse vibration methods could be used to effectively assess the structural integrity of wood floors as component systems. A total of 10 wood floor systems, including 3 laboratory-built floor sections and 7 in-place floors in historic buildings, were tested. A forced vibration method was applied to the floor systems...

  19. Improvement of PVC floor tiles by gamma radiation

    International Nuclear Information System (INIS)

    Plessis, T.A. du; Badenhorst, F.

    1988-01-01

    Gamma radiation presents a unique method of transforming highly plasticized PVC floor tiles, manufactured at high speed through injection moulding, into a high quality floor covering at a cost at least 30% less than similarly rated rubber tiles. A specially formulated PVC compound was developed in collaboration with a leading manufacturer of floor tiles. These tiles are gamma crosslinked in its shipping cartons to form a dimensionally stable product which is highly fire resistant and inert to most chemicals and solvents. These crosslinked tiles are more flexible than the highly filled conventional PVC floor tiles, scratch resistant and have a longer lifespan and increased colour fastness. These tiles are also less expensive to install than conventional rubber tiles. (author)

  20. The pelvic floor muscles: muscle thickness in healthy and urinary-incontinent women measured by perineal ultrasonography with reference to the effect of pelvic floor training. Estrogen receptor studies

    DEFF Research Database (Denmark)

    Bernstein, Inge Thomsen

    1997-01-01

    demonstrated that the striated periurethral muscles and the pelvic floor muscles are of paramount importance for the closure function. This emphasizes the importance of well-functioning pelvic floor muscles to obtain continence, and probably explains the rationale for the effect of pelvic floor training...... in treating urinary incontinence. This study presents a review of the literature on female urinary incontinence, continence mechanisms, pelvic floor muscles, and pelvic floor training. Furthermore, a review of the literature on estrogen receptors in the pelvic floor muscles is given. Perineal ultrasonography...... the effect of pelvic floor training. Additionally, a study of the Pelvic floor muscles was performed to assess the presence of estrogen receptors. Muscle thickness seems to decrease with age. In women over age 60 years, a significantly thinner pelvic floor muscle was found compared to younger women...

  1. Piezoelectric energy harvester under parquet floor

    Science.gov (United States)

    Bischur, E.; Schwesinger, N.

    2011-03-01

    The design, fabrication and testing of piezoelectric energy harvesting modules for floors is described. These modules are used beneath a parquet floor to harvest the energy of people walking over it. The harvesting modules consist of monoaxial stretched PVDF-foils. Multilayer modules are built up as roller-type capacitors. The fabrication process of the harvesting modules is simple and very suitable for mass production. Due to the use of organic polymers, the modules are characterized by a great flexibility and the possibility to create them in almost any geometrical size. The energy yield was determined depending on the dynamic loading force, the thickness of piezoelectric active material, the size of the piezoelectric modules, their alignment in the walking direction and their position on the floor. An increase of the energy yield at higher loading forces and higher thicknesses of the modules was observed. It was possible to generate up to 2.1mWs of electric energy with dynamic loads of 70kg using a specific module design. Furthermore a test floor was assembled to determine the influence of the size, alignment and position of the modules on the energy yield.

  2. Successful surgical treatment of intractable hemifacial spasm: A case report and review of cerebellar hamartomas of the floor of the fourth ventricle

    Directory of Open Access Journals (Sweden)

    Joseph H. Miller

    2016-12-01

    Full Text Available Introduction: Hamartomas involving the floor of the fourth ventricle and cerebellum are rare, but can be associated with medically recalcitrant hemifacial spasm. These lesions present early in the neonatal or infantile period and respond well to surgical excision. Case Report: A 3-month-old white male presented with recurrent left hemifacial spasm, left eye deviation, and absent movement of the extremities. The patient was found to have a left eccentric lesion in the floor of the fourth ventricle and cerebellum. The patient showed no improvement with medical therapy by 6 months of age. He was taken to the operating room for suboccipital craniotomy and removal of the posterior arch of C1 followed by intralesional recording of epileptogenic activity and gross total resection of the lesion. After histologic analysis, the lesion was determined to be ectopic cerebral tissue consistent with a hamartoma. Postoperative MRI showed complete removal of the lesion, and the patient exhibited complete remission of his hemifacial spasm and associated symptoms. Conclusions: Hamartomas involving the floor of the fourth ventricle can present with hemifacial spasm and respond well to surgical excision. Keywords: Cerebellar, Seizure, Epilepsy, Hamartoma

  3. 75 FR 70061 - Dealer Floor Plan Pilot Program Meeting

    Science.gov (United States)

    2010-11-16

    ... SMALL BUSINESS ADMINISTRATION Dealer Floor Plan Pilot Program Meeting AGENCY: U.S. Small Business... location, date, time, and agenda for a meeting regarding the Dealer Floor Plan Pilot Program established in the Small Business Jobs Act of 2010. The meeting will be open to the public. DATES: The Dealer Floor...

  4. Synthetic rubber surface as an alternative to concrete to improve welfare and performance of finishing beef cattle reared on fully slatted flooring.

    Science.gov (United States)

    Brscic, M; Ricci, R; Prevedello, P; Lonardi, C; De Nardi, R; Contiero, B; Gottardo, F; Cozzi, G

    2015-08-01

    The aim of this study was to compare a fully slatted concrete floor (concrete slatted (CS)) with the same floor on which synthetic rubber slats were placed on the concrete slats (rubber slatted (RS)) as housing solution for finishing beef cattle. The present study involved five commercial beef cattle farms in which the floor of at least three pens was kept as fully slatted, and in an equal number of pens a rubber cover was placed on the floor, tightly matching the gap profile of the concrete slats to allow the drainage of manure. A total of 326 finishing beef bulls were used (153 on CS and 173 on RS), and regardless of the floor treatment animals were housed in groups of 6 to 12 bulls/pen with a space allowance of 3.1 ± 0.2 m2/bull. Bulls had similar initial live weights (422.3 kg on CS and 425.0 kg on RS), but bulls on RS were heavier at the end of the finishing period with a higher average daily gain than bulls kept on CS (1.53 v. 1.46 kg/day; Pfloor on growth performance and welfare of finishing beef cattle, although compromising cleanliness and hoof overgrowth.

  5. The Combine Use of Semi-destructive and Non-destructive Methods for Tiled Floor Diagnostics

    Science.gov (United States)

    Štainbruch, Jakub; Bayer, Karol; Jiroušek, Tomáš; Červinka, Josef

    2017-04-01

    The combination of semi-destructive and non-destructive methods was used to asset the conditions of a tiled floor in the historical monument Minaret, situated in the park complex of the Chateau Lednice (South Moravia Region, Czech Republic), before its renovation. Another set of measurements is going to be performed after the conservation works are finished. (The comparison of the results collected during pre- and post-remediation measurements will be known and presented during the General Assembly meeting in Wien.) The diagnostic complex of methods consisted of photogrammetry, resistivity drilling and georadar. The survey was aimed to contour extends of air gaps beneath the tiles and the efficiency of filling gaps by means of injection, consolidation and gluing individual layers. The state chateau Lednice creates a part of the Lednice-Valtice precinct, a UNESCO landmark, and belongs among the greatest historic monuments in Southern Moravia. In the chateau park there is a romantic observation tower in the shape of a minaret built according to the plans of Josef Hardtmuth between 1798-1804. The Minaret has been extensively renovated for many decades including the restoration of mosaic floors from Venetian terazzo. During the static works of the Minaret building between 1999-2000, the mosaic floors in the rooms on the second floor were transferred and put back onto concrete slabs. Specifically, the floor was cut up to tiles and these were glued to square slabs which were then attached to the base plate. The transfer was not successful and the floor restoration was finalized between 2016-2017. The damage consisted in separating the original floor from the concrete plate which led to creating gaps. Furthermore, the layers of the floor were not compact. It was necessary to fill the gaps and consolidate and glue the layers. The existence of air gap between individual layers of the tiles and their degradation was detected using two different diagnostic methods: semi

  6. Ploughing the deep sea floor.

    Science.gov (United States)

    Puig, Pere; Canals, Miquel; Company, Joan B; Martín, Jacobo; Amblas, David; Lastras, Galderic; Palanques, Albert

    2012-09-13

    Bottom trawling is a non-selective commercial fishing technique whereby heavy nets and gear are pulled along the sea floor. The direct impact of this technique on fish populations and benthic communities has received much attention, but trawling can also modify the physical properties of seafloor sediments, water–sediment chemical exchanges and sediment fluxes. Most of the studies addressing the physical disturbances of trawl gear on the seabed have been undertaken in coastal and shelf environments, however, where the capacity of trawling to modify the seafloor morphology coexists with high-energy natural processes driving sediment erosion, transport and deposition. Here we show that on upper continental slopes, the reworking of the deep sea floor by trawling gradually modifies the shape of the submarine landscape over large spatial scales. We found that trawling-induced sediment displacement and removal from fishing grounds causes the morphology of the deep sea floor to become smoother over time, reducing its original complexity as shown by high-resolution seafloor relief maps. Our results suggest that in recent decades, following the industrialization of fishing fleets, bottom trawling has become an important driver of deep seascape evolution. Given the global dimension of this type of fishery, we anticipate that the morphology of the upper continental slope in many parts of the world’s oceans could be altered by intensive bottom trawling, producing comparable effects on the deep sea floor to those generated by agricultural ploughing on land.

  7. Relationship between meanings, emotions, product preferences and personal values. Application to ceramic tile floorings.

    Science.gov (United States)

    Agost, María-Jesús; Vergara, Margarita

    2014-07-01

    This work aims to validate a conceptual framework which establishes the main relationships between subjective elements in human-product interaction, such as meanings, emotions, product preferences, and personal values. The study analyzes the relationships between meanings and emotions, and between these and preferences, as well as the influence of personal values on such relationships. The study was applied to ceramic tile floorings. A questionnaire with images of a neutral room with different ceramic tile floorings was designed and distributed via the web. Results from the study suggest that both meanings and emotions must be taken into account in the generation of product preferences. The meanings given to the product can cause the generation of emotions, and both types of subjective impressions give rise to product preferences. Personal reference values influence these relationships between subjective impressions and product preferences. As a consequence, not only target customers' demographic data but specifically their values and criteria must be taken into account from the beginning of the development process. The specific results of this paper can be used directly by ceramic tile designers, who can better adjust product design (and the subjective impressions elicited) to the target market. Consequently, the chance of product success is reinforced. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. Industrial tests of rock consolidation for fighting floor swelling

    Energy Technology Data Exchange (ETDEWEB)

    Pirskii, A A; Stovpnik, S N [KPI (USSR)

    1990-04-01

    Reports on investigations into the mechanism of floor swelling in main roadways and into rock mass stabilization by consolidating fluid injection combined with blasting. The principal cause of deterioration in the stability of workings is considered to be the state of stress in the rock mass, rock destruction in side walls where rock blocks are being pressed into the floor while the floor rock is squeezed out into the working space. A case study of fluid injection combined with blasting applied in several mines in the Donbass is presented where holes were drilled 1.5-3 m deep and explosive charges of 0.07-0.1 kg/hole and injection of hardening solutions (0.56-0.83 m{sup 3}/m of workings) were applied. As a result floor swelling rates were reduced by up to about 5 times (e.g. from 2.5 mm/d to 0.5 mm/d.). The period of maintenence free upkeep of workings was extended to 6-8 years. The economic effect in maintenance of 1 m of workings was 11.7 rubles for floor consolidation without sidewall bolting and 51.4 rubles for floor consolidation combined with sidewall bolting. Recommendations that concern the technology of floor consolidation by fluid injection and blasting are made. 4 refs.

  9. A novel & affordable interactive floor for educational applications

    DEFF Research Database (Denmark)

    Boisen, Ulrik; Hansen, Anders Juul; Knudsen, Lars

    2011-01-01

    This article examines two research areas: How interactive floors can be used beneficially in an educational context, and how an interactive floor can be created which is mobile and relatively inexpensive....

  10. Modern Theories of Pelvic Floor Support : A Topical Review of Modern Studies on Structural and Functional Pelvic Floor Support from Medical Imaging, Computational Modeling, and Electromyographic Perspectives.

    Science.gov (United States)

    Peng, Yun; Miller, Brandi D; Boone, Timothy B; Zhang, Yingchun

    2018-02-12

    Weakened pelvic floor support is believed to be the main cause of various pelvic floor disorders. Modern theories of pelvic floor support stress on the structural and functional integrity of multiple structures and their interplay to maintain normal pelvic floor functions. Connective tissues provide passive pelvic floor support while pelvic floor muscles provide active support through voluntary contraction. Advanced modern medical technologies allow us to comprehensively and thoroughly evaluate the interaction of supporting structures and assess both active and passive support functions. The pathophysiology of various pelvic floor disorders associated with pelvic floor weakness is now under scrutiny from the combination of (1) morphological, (2) dynamic (through computational modeling), and (3) neurophysiological perspectives. This topical review aims to update newly emerged studies assessing pelvic floor support function among these three categories. A literature search was performed with emphasis on (1) medical imaging studies that assess pelvic floor muscle architecture, (2) subject-specific computational modeling studies that address new topics such as modeling muscle contractions, and (3) pelvic floor neurophysiology studies that report novel devices or findings such as high-density surface electromyography techniques. We found that recent computational modeling studies are featured with more realistic soft tissue constitutive models (e.g., active muscle contraction) as well as an increasing interest in simulating surgical interventions (e.g., artificial sphincter). Diffusion tensor imaging provides a useful non-invasive tool to characterize pelvic floor muscles at the microstructural level, which can be potentially used to improve the accuracy of the simulation of muscle contraction. Studies using high-density surface electromyography anal and vaginal probes on large patient cohorts have been recently reported. Influences of vaginal delivery on the

  11. Management of disorders of the posterior pelvic floor.

    Science.gov (United States)

    Berman, Loren; Aversa, John; Abir, Farshad; Longo, Walter E.

    2005-01-01

    INTRODUCTION: Constipation is a relatively common problem affecting 15 percent of adults in the Western world, and over half of these cases are related to pelvic floor disorders. This article reviews the clinical presentation and diagnostic approach to posterior pelvic floor disorders, including how to image and treat them. METHODS: A Pubmed search using keywords "rectal prolapse," "rectocele," "perineal hernia," and "anismus" was performed, and bibliographies of the revealed articles were cross-referenced to obtain a representative cross-section of the literature, both investigational studies and reviews, that are currently available on posterior pelvic floor disorders. DISCUSSION: Pelvic floor disorders can occur with or without concomitant physical anatomical defects, and there are a number of imaging modalities available to detect such abnormalities in order to decide on the appropriate course of treatment. Depending on the nature of the disorder, operative or non-operative therapy may be indicated. CONCLUSION: Correctly diagnosing pelvic floor disorders can be complex and challenging, and the various imaging modalities as well as clinical history and exam must be considered together in order to arrive at a diagnosis. PMID:16720016

  12. Long-term experiment with orchard floor management systems: influence on apple yield and chemical composition.

    Science.gov (United States)

    Slatnar, Ana; Licznar-Malanczuk, Maria; Mikulic-Petkovsek, Maja; Stampar, Franci; Veberic, Robert

    2014-05-07

    The study focuses on the response of apple primary and secondary metabolism and some important quality parameters to three living mulch treatments, classical herbicide fallow, and black polypropylene strip application in two apple cultivars. Primary and secondary metabolites were analyzed after 10 years of ground cover experiments. Soluble solids, firmness, and color measurements indicate differences among orchard floor management treatments. Significantly, lower levels of individual sugars have been measured in fruit of different living mulch treatments compared with fruit harvested from trees subjected to the herbicide strip treatment. Total sugar content was higher in fruit of the herbicide strip treatment in both cultivars analyzed. Significantly higher levels of total organic acids were only detected in 'Pinova' fruit of the Festuca ovina L. treatment. Long-term response of both cultivars to living mulch treatments indicated that apples increase the accumulation of almost all analyzed individual phenolic compounds.

  13. Special aspects of attic floor warming in historic buildings

    Directory of Open Access Journals (Sweden)

    Murgul Vera

    2017-01-01

    Full Text Available This article containsreasoningof the heat transfer performance uniformity factor determination for attic floors of historic residential buildings while energy effective modifying buildings. The numeral value of this heat transfer performance uniformity factor for the wooden attic floor structure was founddurung investigation. It was estimated that there was no moisture condensation in the wooden attic floor structure.

  14. Short communication: Flooring preferences of dairy cows at calving.

    Science.gov (United States)

    Campler, M; Munksgaard, L; Jensen, M B; Weary, D M; von Keyserlingk, M A G

    2014-02-01

    The present study investigated the flooring preference during the 30 h before parturition in Holstein dairy cows housed individually in a maternity pen. Seventeen multiparous cows were moved, on average, 2 d before expected calving date into an individual maternity pen with 3 different flooring surfaces: 10 cm of sand, pebble-top rubber mats, or concrete flooring, each covered with 15 cm of straw. Calving location, lying time, and total time and number of lying bouts on each of the floor types were recorded during 2 periods: precalving (24 to 29 h before calving) and at calving (0 to 5h before calving). Ten cows calved on sand, 6 on concrete, and 1 on the rubber mat. Lying bouts increased during the hours closest to calving, regardless of flooring. The number of lying bouts did not differ between flooring types precalving but cows had more lying bouts on sand and concrete compared with rubber at calving. Cows spent more time lying down on sand and concrete compared with rubber precalving, but lying times did not differ between treatments at calving. Cows that calved on sand spent more time lying on sand at calving compared with the other 2 flooring types. Cows that calved on concrete did not show a flooring preference at calving. These results indicate that rubber mats are the least preferred by dairy cows in the maternity pens, even when covered with a deep layer of straw. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Obtaining and Estimating Low Noise Floors in Vibration Sensors

    DEFF Research Database (Denmark)

    Brincker, Rune; Larsen, Jesper Abildgaard

    2007-01-01

    For some applications like seismic applications and measuring ambient vibrations in structures, it is essential that the noise floors of the sensors and other system components are low and known to the user. Some of the most important noise sources are reviewed and it is discussed how the sensor...... can be designed in order to obtain a low noise floor. Techniques to estimate the noise floors for sensors are reviewed and are demonstrated on a commercial commonly used sensor for vibration testing. It is illustrated how the noise floor can be calculated using the coherence between simultaneous...

  16. CAISSON TYPE HOLLOW FLOOR SLABS OF MONOLITHIC MULTI-STOREYED BUILDINGS

    Directory of Open Access Journals (Sweden)

    Malakhova Anna Nikolaevna

    2016-06-01

    Full Text Available One of the disadvantages of building structures made of reinforced concrete is their considerable weight. One of the trends to decrease the weight of concrete structures, including floor slabs, is the arrangement of voids in the cross-sectional building structures. In Russian and foreign practice paper, cardboard and plastic tubes has been used for creation of voids in the construction of monolithic floor slabs. Lightweight concretes were also used for production of precast hollow core floor slabs. The article provides constructive solutions of precast hollow core floor slabs and solid monolithic slabs that were used in the construction of buildings before wide use of large precast hollow core floor slabs. The article considers the application of caisson hollow core floor slabs for modern monolithic multi-storeyed buildings. The design solutions of such floor slabs, experimental investigations and computer modeling of their operation under load were described in this article. The comparative analysis of the calculation results of computer models of a hollow slabs formed of rod or plastic elements showed the similarity of calculation results.

  17. Global floor planning approach for VLSI design

    International Nuclear Information System (INIS)

    LaPotin, D.P.

    1986-01-01

    Within a hierarchical design environment, initial decisions regarding the partitioning and choice of module attributes greatly impact the quality of the resulting IC in terms of area and electrical performance. This dissertation presents a global floor-planning approach which allows designers to quickly explore layout issues during the initial stages of the IC design process. In contrast to previous efforts, which address the floor-planning problem from a strict module placement point of view, this approach considers floor-planning from an area planning point of view. The approach is based upon a combined min-cut and slicing paradigm, which ensures routability. To provide flexibility, modules may be specified as having a number of possible dimensions and orientations, and I/O pads as well as layout constraints are considered. A slicing-tree representation is employed, upon which a sequence of traversal operations are applied in order to obtain an area efficient layout. An in-place partitioning technique, which provides an improvement over previous min-cut and slicing-based efforts, is discussed. Global routing and module I/O pin assignment are provided for floor-plan evaluation purposes. A computer program, called Mason, has been developed which efficiently implements the approach and provides an interactive environment for designers to perform floor-planning. Performance of this program is illustrated via several industrial examples

  18. Pelvic floor dysfunction, and effects of pregnancy and mode of delivery on pelvic floor

    Directory of Open Access Journals (Sweden)

    Murat Bozkurt

    2014-12-01

    Full Text Available Pelvic floor dysfunction (PFD, although seems to be simple, is a complex process that develops secondary to multifactorial factors. The incidence of PFD is increasing with increasing life expectancy. PFD is a term that refers to a broad range of clinical scenarios, including lower urinary tract excretory and defecation disorders, such as urinary and anal incontinence, overactive bladder, and pelvic organ prolapse, as well as sexual disorders. It is a financial burden on the health care system and disrupts women's quality of life. Strategies applied to decrease PFD are focused on the course of pregnancy, mode and management of delivery, and pelvic exercise methods. Many studies in the literature define traumatic birth, usage of forceps, length of the second stage of delivery, and sphincter damage as modifiable risk factors for PFD. Maternal age, fetal position, and fetal head circumference are nonmodifiable risk factors. Although numerous studies show that vaginal delivery affects pelvic floor structures and their functions in a negative way, there is not enough scientific evidence to recommend elective cesarean delivery in order to prevent development of PFD. PFD is a heterogeneous pathological condition, and the effects of pregnancy, vaginal delivery, cesarean delivery, and possible risk factors of PFD may be different from each other. Observational studies have identified certain obstetrical exposures as risk factors for pelvic floor disorders. These factors often coexist; therefore, the isolated effects of these variables on the pelvic floor are difficult to study. The routine use of episiotomy for many years in order to prevent PFD is not recommended anymore; episiotomy should be used in selected cases, and the mediolateral procedures should be used if needed.

  19. Laparoscopic Pelvic Floor Repair Using Polypropylene Mesh

    Directory of Open Access Journals (Sweden)

    Shih-Shien Weng

    2008-09-01

    Conclusion: Laparoscopic pelvic floor repair using a single piece of polypropylene mesh combined with uterosacral ligament suspension appears to be a feasible procedure for the treatment of advanced vaginal vault prolapse and enterocele. Fewer mesh erosions and postoperative pain syndromes were seen in patients who had no previous pelvic floor reconstructive surgery.

  20. Detection of lunar floor-fractured craters using machine learning methods

    Science.gov (United States)

    Thorey, C.

    2015-10-01

    About 200 Floor Fractured Craters (FFCs) have been identified by Schultz (1976) on the Moon, mainly around the lunar maria. These craters are a class of impact craters that are distinguished by having radi-ally and concentric floor-fractured networks and ab-normally shallow floors. In some cases, the uplift of the crater floor can be as large as 50% of the initial crater depth. These impact craters are interpreted to have undergone endogenous deformations after their formation.

  1. 29 CFR 1910.23 - Guarding floor and wall openings and holes.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Guarding floor and wall openings and holes. 1910.23 Section... floor and wall openings and holes. (a) Protection for floor openings. (1) Every stairway floor opening... opening and hole shall be guarded by a standard skylight screen or a fixed standard railing on all exposed...

  2. Feedback damping of a microcantilever at room temperature to the minimum vibration amplitude limited by the noise level.

    Science.gov (United States)

    Kawamura, Y; Kanegae, R

    2016-06-17

    Cooling the vibration amplitude of a microcantilever as low as possible is important to improve the sensitivity and resolutions of various types of scanning type microscopes and sensors making use of it. When the vibration amplitude is controlled to be smaller using a feed back control system, it is known that the obtainable minimum amplitude of the vibration is limited by the floor noise level of the detection system. In this study, we demonstrated that the amplitude of the thermal vibration of a microcantilever was suppressed to be about 0.15 pmHz(-1/2), which is the same value with the floor noise level, without the assistance of external cryogenic cooling. We think that one of the reason why we could reach the smaller amplitude at room temperature is due to stiffer spring constant of the lever, which leads to higher natural frequency and consequently lower floor noise level. The other reason is considered to be due to the increase in the laser power for the diagnostics, which lead to the decrease in the signal to noise ratio determined by the optical shot noise.

  3. 40 CFR 427.70 - Applicability; description of the asbestos floor tile subcategory.

    Science.gov (United States)

    2010-07-01

    ... asbestos floor tile subcategory. 427.70 Section 427.70 Protection of Environment ENVIRONMENTAL PROTECTION... Asbestos Floor Tile Subcategory § 427.70 Applicability; description of the asbestos floor tile subcategory... manufacture of asbestos floor tile. ...

  4. An education program about pelvic floor muscles improved women's knowledge but not pelvic floor muscle function, urinary incontinence or sexual function: a randomised trial.

    Science.gov (United States)

    de Andrade, Roberta Leopoldino; Bø, Kari; Antonio, Flavia Ignácio; Driusso, Patricia; Mateus-Vasconcelos, Elaine Cristine Lemes; Ramos, Salvador; Julio, Monica Pitanguy; Ferreira, Cristine Homsi Jorge

    2018-04-01

    Does an educational program with instructions for performing 'the Knack' improve voluntary contraction of the pelvic floor muscles, reduce reports of urinary incontinence, improve sexual function, and promote women's knowledge of the pelvic floor muscles? Randomised, controlled trial with concealed allocation, intention-to-treat analysis and blinded assessors. Ninety-nine women from the local community. The experimental group (n=50) received one lecture per week for 4 weeks, and instructions for performing 'the Knack'. The control group (n=49) received no intervention. The primary outcome was maximum voluntary contraction of the pelvic floor muscles measured using manometry. Secondary outcomes were: ability to contract the pelvic floor muscles measured using vaginal palpation; severity of urinary incontinence measured by the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) scored from 0 to 21; self-reported sexual function; and knowledge related to the pelvic floor. Outcomes were measured at baseline and after 4 weeks. The intervention did not significantly improve: maximum voluntary contraction (MD 2.7 cmH 2 O higher in the experimental group, 95% CI -0.5 to 5.9); ability to contract the pelvic floor muscles (RR 2.18, 95% CI 0.49 to 9.65); or self-reported severity of urinary incontinence (MD 1 point greater reduction in the experimental group, 95% CI -3 to 1). Sexual function did not significantly differ between groups, but very few of the women engaged in sexual activity during the study period. The educational program did, however, significantly increase women's knowledge related to the location, functions and dysfunctions of the pelvic floor muscles, and treatment options. Education and teaching women to perform 'the Knack' had no significant effect on voluntary contraction of the pelvic floor muscles, urinary incontinence or sexual function, but it promoted women's knowledge about the pelvic floor. Brazilian Registry of Clinical

  5. The radiation protection environmental assesment for 60Co irradiation room

    International Nuclear Information System (INIS)

    Zheng Meiyang; Jin Guohua; Shen Genfang

    2010-01-01

    60 Co source is applied in the process such as sterilizing agricultural products in irradiation room of some Academy of Agricultural Sciences, which is very effective in agricultural applications. However, 60 Co is highly toxic, once the leak, the consequences would be disastrous. So it is necessary to summarize the radiation protection and safety evaluation of the irradiation room indoor and outdoor, to ensure the health and lives of the staff and the surrounding population. The radiation detectors monitor six points around the irradiation room. Results show that design of irradiation room of Academy of Agricultural Sciences are mostly safe and reliable, regardless of the source in working condition. And consequences also show 60 Co source in the normal operating will not put adverse effects on the surrounding environment. In addition, the outer radiation protective measures are also outlined, in view of 60 Co own identity. (authors)

  6. Generation of floor response spectra for PFBR RCB

    International Nuclear Information System (INIS)

    Sajish, S.D.; Ramakrishna, V.; Chellapandi, P.; Chetal, S.C.

    2003-01-01

    This paper describes the generation of floor time histories and corresponding floor response spectrums at various locations in reactor containment building (RCB) for 500 MWe Prototype Fast Breeder Reactor (PFBR). The RCB and its internal structures are modeled with equivalent 3D-beam elements (stick model), which have got the essential global stiffness and inertial properties of the corresponding building. The main aspect in the simulation of beam model is derivation of equivalent cross sectional properties such as bending, torsional and shear rigidities including shear centers. These properties have been obtained through 3D plate/shell element models with appropriate kinematic constraints, for the zones between floors of corresponding buildings. The stick model includes a set of springs and dampers to simulate soil effects, on which base raft and various sticks are mounted. The soil stiffness and damping values are derived based on equations given in ASCE-98. Time history analysis has been done using three uncorrelated time histories, which are derived from the site dependent design response spectra. Floor time histories (FTH) are extracted at important locations from which the corresponding floor response spectrums (FRS) have been generated for various damping values. Peak broadening of the response spectrums has been done according ASCE criteria. Floor response spectrum corresponds to reactor assembly support shows amplification 2.5 for SSE and 3 for OBE. CASTEM 3M is used for seismic analysis and generation of FRS. (author)

  7. Portable flooring protects finished surfaces, is easily moved

    Science.gov (United States)

    Carmody, R. J.

    1964-01-01

    To protect curved, finished surface and provide support for workmen, portable flooring has been made from rigid plastic foam blocks, faced with aluminum strips. Held together by nylon webbing, the flooring can be rolled up for easy carrying.

  8. Dance floors as injury risk: analysis and evaluation of acute injuries caused by dance floors in professional dance with regard to preventative aspects.

    Science.gov (United States)

    Wanke, Eileen M; Mill, Helmgard; Wanke, Alice; Davenport, Jaqueline; Koch, Franziska; Groneberg, David A

    2012-09-01

    A dance floor is often the only support of movements in dance. A dance floor surface that shows deficiencies, can result in acute injuries and chronic problems. Although the significance of an adequate dance floor is well known, there is still a lack of differentiated analyses of dance floor-related acute injuries. This study presents data on acute injuries exclusively caused by the dance floor. The data were obtained from standardized work accident reports from consultants (F 1000), documentary accident records from all Berlin theatres, a state ballet school (n=2,281), and case records from the Berlin State Accident Insurance (UKB) covering a period of 17 years. All analyses and descriptive statistics were conducted with Excel 2007 and SPSS 18. Dance floor surfaces were the causative factor in 12.8% of all accidents (n=291, female 183, male 108). Almost two thirds (62.6%) of all accidents in professional dancers happened on stage, and almost half (49.5%) occurred during performances. As for causative factors, 53.1% of the professional dancers (P) and 42.5% of the dance students (S) claimed that the floor had been "too slippery," with "getting stuck" or (tripping) as the second most common problem (P 18.4%, S 11.3%). Of the injured dancers, 41.8% were older than 30 years and can therefore be categorized as experienced. Dance floors play a significant role in the occurrence of acute injuries, even in experienced dancers. Performances on stage seem to be a particular risk. However, injury prevention measures should include all work locations (P) as well as non-dance-specific locations (S).

  9. The Influence of Room Colors in A House for Its Occupants

    Directory of Open Access Journals (Sweden)

    Dila Hendrassukma

    2016-01-01

    Full Text Available Home was a place where each individual could go after doing various routine activities. Residential interior design would support the quality of life of its occupants. The majority of the population of Indonesia, especially in Jakarta, had been aware of the importance of design interior of their homes properly. However, the selection of interior elements of color that was supporting the smoothness of the activities in a room was not considered as whole. The research objective was to analyze a great color for every room in the home based on the theory and the psychology of color. This article was expected to be a guide for those who will design an interior room. The method used was qualitative method in the form of observation and study of literature. Results of the study is the choice of a suitable color that fit in any room home, such as the living room, bedroom, kitchen, and bathroom can maximize the function of the room for the occupants. 

  10. 27 CFR 46.195 - Floor stocks requirements.

    Science.gov (United States)

    2010-04-01

    ... Tubes Held for Sale on April 1, 2009 General § 46.195 Floor stocks requirements. (a) Take inventory. The dealer must establish the quantity of articles subject to the floor stocks tax held for sale on April 1, 2009. The dealer may take a physical inventory or may use a record (book) inventory, as specified in...

  11. [Quality of life in women with pelvic floor dysfunction].

    Science.gov (United States)

    Segedi, Ljiljana Mladenović; Ilić, Katarina Parezanović; Curcić, Aleksandar; Visnjevac, Nemanja

    2011-11-01

    Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfaction in adult women with pelvic organ prolapse presenting to tertiary care clinic for surgical treatment. This prospective case-control study included 50 patients who presented to tertiary care gynecology clinic for surgical treatment and 50 controls with normal pelvic floor support and without urinary incontinence who presented tertiary care gynecology clinic for other reasons. Both, patients and controls, completed two quastionnaires recommended for the evaluation of symptoms (Pelvic floor distress inventory - short forms) and quality of life impact (Pelvic floor impact questionnaire - short form) of pelvic organ prolapse, and Body Image Scale. The patients scored significantly worse on the prolapse, urinary, colorectal scales and overall score of Pelvic floor distress inventory--20 than controls subjects (134.91 vs 78.08; p self-conscious (78% vs 42%; p body. There was a positive correlation between decreased quality of life and body image in women with pelvic dysfunction. Women with pelvic floor dysfunction have decreased quality of life and body image.

  12. Anonymous electronic trading versus floor trading

    OpenAIRE

    Franke, Günter; Hess, Dieter

    1995-01-01

    This paper compares the attractiveness of floor trading and anonymous electronic trading systems. It is argued that in times of low information intensity the insight into the order book of the electronic trading system provides more valuable information than floor trading, but in times of high information intensity the reverse is true. Thus, the electronic system's market share in trading activity should decline in times of high information intensity. This hypothesis is tested by data on BUND...

  13. Effect of slatted and solid floors and permeability of floors in pig houses on environment, animal welfare and health and food safety: a review of literature

    NARCIS (Netherlands)

    Vermeij, I.; Enting, J.; Spoolder, H.A.M.

    2009-01-01

    An integrated approach can improve understanding of floor performance. Not only gap width or percentage of slatted floor is important, but a minimum percentage of permeability of the total floor area appears to be decisive

  14. Imaging of the posterior pelvic floor

    International Nuclear Information System (INIS)

    Stoker, Jaap; Bartram, Clive I.; Halligan, Steve

    2002-01-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  15. Imaging of the posterior pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands); Bartram, Clive I.; Halligan, Steve [Intestinal Imaging Centre, St. Mark' s Hospital, London (United Kingdom)

    2002-04-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  16. Predictive multiscale computational model of shoe-floor coefficient of friction.

    Science.gov (United States)

    Moghaddam, Seyed Reza M; Acharya, Arjun; Redfern, Mark S; Beschorner, Kurt E

    2018-01-03

    Understanding the frictional interactions between the shoe and floor during walking is critical to prevention of slips and falls, particularly when contaminants are present. A multiscale finite element model of shoe-floor-contaminant friction was developed that takes into account the surface and material characteristics of the shoe and flooring in microscopic and macroscopic scales. The model calculates shoe-floor coefficient of friction (COF) in boundary lubrication regime where effects of adhesion friction and hydrodynamic pressures are negligible. The validity of model outputs was assessed by comparing model predictions to the experimental results from mechanical COF testing. The multiscale model estimates were linearly related to the experimental results (p < 0.0001). The model predicted 73% of variability in experimentally-measured shoe-floor-contaminant COF. The results demonstrate the potential of multiscale finite element modeling in aiding slip-resistant shoe and flooring design and reducing slip and fall injuries. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  17. Common floor system vertical earthquake-proof structure for reactor equipment

    International Nuclear Information System (INIS)

    Morishita, Masaki.

    1996-01-01

    In an LMFBR type reactor, a reactor container, a recycling pump and a heat exchanger are disposed on a common floor. Vertical earthquake-proof devices which can be stretched only in vertical direction formed by laminating large-sized bellevilles are disposed on a concrete wall at the circumference of each of reactor equipments. A common floor is placed on all of the vertical earthquake-proof devices to support the entire earthquake-proof structure simultaneously. If each of reactor equipments is loaded on the common floor and the common floor is entirely supported against earthquakes altogether, since the movement of each of the reactor equipments loaded on the common floor is identical, relative dislocation is not exerted on the main pipelines which connect the equipments. In addition, since the entire earthquake structure has a flat common floor and each of the reactor equipments is suspended to minimize the distance between a gravitational center and a support point, locking vibration is less caused to the horizontal earthquake. (N.H.)

  18. Functional imaging of the pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Lienemann, Andreas E-mail: andreaslienemann@web.de; Fischer, Tanja

    2003-08-01

    Introduction/Objective: Pelvic floor dysfunction and associated pelvic organ prolapse represent a major problem in our present-day society, mostly afflicting parous women. Magnetic resonance imaging (MRI) is assuming an increasingly important role in the more accurate delineation of the extent of the problem. This article briefly reviews one of the main radiological methods for the dynamic evaluation of the pelvic floor: functional cine MRI. Methods and Material: Out of the literature the smallest common denominator for functional cine MRI can be defined as follows: high field system; patient either in supine or sitting position; fast gradient echo sequence; midsagittal slice orientation; either a stack of slices or repeated measurements at the same slice position with the patient at rest or straining; image analysis using the pubococcygeal reference line. Results: All except two publications stress the usefulness of functional cine MRI in the evaluation of patients with organ descent and prolapse. This well accepted method allows for the visualization of all relevant structures in the anterior, middle and posterior compartment. It is especially useful in the detection of enteroceles, and provides a reliable postoperative follow-up tool. Isolated urinary or stool incontinence are not an indication for functional cine MRI, as is the case in patients with equivocal clinical findings. To date it does not allow for real 3D imaging of the pelvic floor or sufficient determination of fascial defects. Discussion: Functional cine MRI of the pelvic floor is a promising new imaging method for the detection of organ descent and prolapse in patients with equivocal clinical findings. The combination of function and morphology allows for an innovative view of the pelvic floor, and thus adds to our understanding of the various interactions of the structures.

  19. Modelling floor heating systems using a validated two-dimensional ground coupled numerical model

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Kragh, Jesper; Roots, Peter

    2005-01-01

    This paper presents a two-dimensional simulation model of the heat losses and tempera-tures in a slab on grade floor with floor heating which is able to dynamically model the floor heating system. The aim of this work is to be able to model, in detail, the influence from the floor construction...... the floor. This model can be used to design energy efficient houses with floor heating focusing on the heat loss through the floor construction and foundation. It is found that it is impor-tant to model the dynamics of the floor heating system to find the correct heat loss to the ground, and further......, that the foundation has a large impact on the energy consumption of buildings heated by floor heating. Consequently, this detail should be in focus when designing houses with floor heating....

  20. Do women with pelvic floor dysfunction referred by gynaecologists and urologists at hospitals complete a pelvic floor muscle training programme?

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Dehlendorff, Christian

    2013-01-01

    For decades women with pelvic floor dysfunction (PFD) have been referred to pelvic floor muscle training (PFMT), but there is only little information on whether the women complete the programmes and why. The objectives of this study were to investigate to which extent women completed a PFMT...

  1. Radon in Norwegian dwellings

    International Nuclear Information System (INIS)

    Strand, T.; Green, B.M.R; Lomas, P.R.; Mangnus, K.; Stranden, E.

    1991-01-01

    Measurements of radon in indoor air have been made in a total of about 7500 randomly selected dwellings in Norway from all parts of the country. The number of selected dwellings in each municipality is about proportional to its population, except for the two largest municipalities, Oslo and Bergen, where somewhat smaller samples were taken due to the higher population density. The measurements were performed by nuclear track detectors from the National Radiological Protection Boards in United Kingdom, and the integration time for the measurements was 6 months. The detectors were spread evenly over all seasons of the year to eliminate influence from seasonal variation in the radon level. One single measurement was performed in each dwelling: in the main bedroom. The results shows that the distribution of radon concentrations in Norwegian bedrooms is log-normal. The aritmetic mean of the measurements, including all categories of dwellings, is calculated to be 51 Bq/m 3 and the corresponding geometric mean to be 26 Bq/m 3 . In a large proportion of single-family houses the living room and the kitchen are located on the ground floor while the bedrooms are located one floor higher. The results of the study shows that the radon level is somewhat higher at the ground floor than on the first floor, and higher in the basement than on the first floor. Taking this into account, and assuming that measurements in bedrooms on the first floor is a representative average for living room and kitchen, the average radon concentration for Norwegian dwellings is estimated to be between 55-65 Bq/m 3 . In this estimate, possible influences of the fact that the winters 87/88 and 88/89 were much warmer than normal and may therefor have lowered the results, has been taken into account. 15 refs., 9 figs., 15 tabs

  2. Indoor radon seasonal variability at different floors of buildings

    International Nuclear Information System (INIS)

    De Francesco, S.; Tommasone, F. Pascale; Cuoco, E.; Tedesco, D.

    2010-01-01

    Indoor radon concentrations have been measured with the α track etch integrated method in public buildings in the town of Pietramelara, north-western Campania, Southern Italy. In particular, our measurements were part of an environmental monitoring program originally aimed at assessing the range of seasonal fluctuations in indoor radon concentrations, at various floors of the studied buildings. However, subsequent analysis of the data and its comparison with the meteorological data recorded in the same period has shown an unexpected pattern at the different floors. In this report we present data suggesting that, besides the well-known medium and longterm periodicity, there could also be a differentiation in major meteorological controlling factors at the different floors of the buildings, a fact that does not appear to have been reported previously. While the lower floors proved to be markedly affected by rainfall, for the upper floors, instead, a different behaviour has been detected, which could possibly be related to global solar radiation.

  3. Factors controlling indoor radon levels. Annual report, June 1983-May 1984

    International Nuclear Information System (INIS)

    Harley, N.H.

    1984-01-01

    The factors which contribute to indoor radon levels were investigated. Soil moisture content appears to be such a factor and influences indoor radon levels in a subtle way. The single family dwelling studied here is a typical suburban home, with a full basement, two living levels and a full attic. Seasonal data for 1981 to 1983 are shown by hour (about 90 hours in each average) for the basement, first floor and outdoors. A twenty-five story, 225 apartment, high rise building has been under study for about the same time interval. The apartment has five rooms, and is on the 24th floor. Continuous monitors are located in a work room and outdoors on a terrace. Data are available from the summer of 1981. 2 references, 12 figures, 9 tables

  4. Pelvic floor spasm as a cause of voiding dysfunction.

    Science.gov (United States)

    Kuo, Tricia L C; Ng, L G; Chapple, Christopher R

    2015-07-01

    Pelvic floor disorders can present with lower urinary tract symptoms, bowel, sexual dysfunction, and/or pain. Symptoms of pelvic muscle spasm (nonrelaxing pelvic floor or hypertonicity) vary and can be difficult to recognize. This makes diagnosis and management of these disorders challenging. In this article, we review the current evidence on pelvic floor spasm and its association with voiding dysfunction. To distinguish between the different causes of voiding dysfunction, a video urodynamics study and/or electromyography is often required. Conservative measures include patient education, behavioral modifications, lifestyle changes, and pelvic floor rehabilitation/physical therapy. Disease-specific pelvic pain and pain from pelvic floor spasm needs to be differentiated and treated specifically. Trigger point massage and injections relieves pain in some patients. Botulinum toxin A, sacral neuromodulation, and acupuncture has been reported in the management of patients with refractory symptoms. Pelvic floor spasm and associated voiding problems are heterogeneous in their pathogenesis and are therefore often underrecognized and undertreated; it is therefore essential that a therapeutic strategy needs to be personalized to the individual patient's requirements. Therefore, careful evaluation and assessment of individuals using a multidisciplinary team approach including a trained physical therapist/nurse clinician is essential in the management of these patients.

  5. Endoscopic anatomy of the orbital floor and maxillary sinus.

    Science.gov (United States)

    Moore, Corey C; Bromwich, Matthew; Roth, Kathy; Matic, Damir B

    2008-01-01

    Endoscopic repair of orbital blow-out fractures could become a predictable and efficient treatment alternative to traditional methods. However, maxillary sinus endoscopy provides a complex and disorienting view of the orbital floor. To be a useful and consistent technique for providing access to the orbital floor, specific knowledge of maxillary endoscopic anatomy is required. The purpose of the study was to provide an anatomic description of the orbital floor via the endoscopic approach. Objectives include defining consistent landmarks for use in endoscopic repair of orbital floor fractures. Using 0- and 30-degree rigid endoscopes, 6 fresh cadavers (12 maxillary sinuses) were examined via a standard Caldwell-Luc approach. Computed tomographic scans, plastic molds, and digital images were used to compare observable averages within bony anatomy. Potential bony landmarks were correlated with soft-tissue anatomy in fresh specimens. The maxillary ostium, orbital floor, and lateral ethmoid air cells were visualized, and their structures were described. Observations were made in relation to the anatomy of the orbital floor and maxillary sinus, including fracture pattern and force transmission pathways. An "orbitomaxillary" sinus bony thickening was identified and described for the first time. This study provides the basis for further refinement of surgical technique and opens the door for future clinical trials using endoscopic repair.

  6. Nuclear reactor cavity floor passive heat removal system

    Science.gov (United States)

    Edwards, Tyler A.; Neeley, Gary W.; Inman, James B.

    2018-03-06

    A nuclear reactor includes a reactor core disposed in a reactor pressure vessel. A radiological containment contains the nuclear reactor and includes a concrete floor located underneath the nuclear reactor. An ex vessel corium retention system includes flow channels embedded in the concrete floor located underneath the nuclear reactor, an inlet in fluid communication with first ends of the flow channels, and an outlet in fluid communication with second ends of the flow channels. In some embodiments the inlet is in fluid communication with the interior of the radiological containment at a first elevation and the outlet is in fluid communication with the interior of the radiological containment at a second elevation higher than the first elevation. The radiological containment may include a reactor cavity containing a lower portion of the pressure vessel, wherein the concrete floor located underneath the nuclear reactor is the reactor cavity floor.

  7. Comparison of changes in the mobility of the pelvic floor muscle on during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction

    OpenAIRE

    Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho

    2016-01-01

    [Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility...

  8. Validation of the Pelvic Floor Distress Inventory-20 and the Pelvic Floor Impact Questionnaire-7 in Danish women with pelvic organ prolapse

    DEFF Research Database (Denmark)

    Due, Ulla; Brostrøm, Søren; Lose, Gunnar

    2013-01-01

    To translate the Pelvic Floor Distress Inventory-20 (PFDI-20) and the Pelvic Floor Impact Questionnaire-7 (PFIQ-7) and to evaluate their psychometric properties in Danish women with symptomatic pelvic organ prolapse....

  9. Development of rationalized system treating floor drain

    International Nuclear Information System (INIS)

    Nakamura, Yasuyuki; Serizawa, Kenichi; Komatsu, Akihiro; Shimizu, Takayuki

    1998-01-01

    Radioactive liquid wastes generated at BWR plants are collected and treated as required. These days, however, generation of floor drain has deceased and HFF (Hollow Fiber Filter) has experienced a wide applicability to several kinds of liquid wastes. We should consider that the floor drain can be mixed and diluted with equipment drain and be purified by HFF. That enables some of the sumps and long priming pipes to be combined. From this point of view, we have developed a highly rationalized waste liquid system. We have evaluated the applicability of this system after an investigation into the generation and properties of floor drain and equipment drain at the latest BWR'S and an on-site test at a typical BWR. (author)

  10. Room Temperature Magnetic Determination of the Current Center Line for the ITER TF Coils

    CERN Document Server

    Lerch, Philippe; Buzio, Marco; Negrazus, Marco; Baynham, Elwyn; Sanfilippo, Stephane; Foussat, Arnaud

    2014-01-01

    The ITER tokamak includes 18 superconducting D-shaped toroidal field (IT) coils. Unavoidable shape deformations as well as assembly errors will lead to field errors, which can be modeled with the knowledge of the current center line (CCL). Accurate survey during the entire manufacturing and assembly process, including transfer of survey points, is complex. In order to increase the level of confidence, a room temperature magnetic measurement of the CCL on assembled and closed winding packs is foreseen, prior to insertion into their cold case. In this contribution, we discuss the principle of the CCL determination and present a low frequency ac measurement system under development at PSI, within an ITER framework contract. The largest current allowed to flow in the TF coil at room temperature and the precision requirements for the determination of the CCL loci of the coil are hard boundaries. Eddy currents in the radial plates, the winding pack enclosures, and possibly from iron in the reinforced concrete floor...

  11. Help-seeking behaviour for pelvic floor dysfunction in women over 55: drivers and barriers.

    Science.gov (United States)

    Tinetti, Amy; Weir, Nicole; Tangyotkajohn, Usanee; Jacques, Angela; Thompson, Judith; Briffa, Kathy

    2018-03-19

    Our aim was to identify drivers of and barriers to help-seeking behaviour of older women with pelvic floor dysfunction (PFD) living independently in Australia . Women aged ≥55 years were recruited to this cross-sectional study during July and August 2016. Bladder, bowel, pelvic organ prolapse (POP) and sexual dysfunction were assessed with the Australian Pelvic Floor Questionnaire (APFQ). Drivers and barriers were based on the Barriers to Incontinence Care Seeking Questionnaire. Univariate analyses were used to assess any significant relationships between PFD, age, education level, self-reported PFD, barriers and drivers. Of the 376 study participants [mean, standard deviation (SD) age 68.6 (10.5) years], 67% reported symptoms of PFD and 98.7% scored >0 on the APFQ. Women were more likely to seek help if they scored higher on the APFQ (p help was the perception that PFD was a normal part of ageing (22.4%). Of those who did seek help (50%), the main factor was increased level of symptom bother (51.4%). There was no difference in age or education level between women who did and did not seek help. Women are more likely to seek help for PFD if scoring higher on the APFQ or symptoms are becoming more bothersome. They are less likely to seek help if they view their symptoms as normal. Future direction should be taken to raise awareness of normal pelvic floor function as well as the availability of help for PFD.

  12. Radon daughter concentrations in and around dwellings in the northern part of the Netherlands

    International Nuclear Information System (INIS)

    Wolfs, F.; Hofstede, H.; Meijer, R.J. de; Put, L.W.

    1984-01-01

    The concentration of radon daughters in and around 80 dwellings located in the northern part of the Netherlands has been determined using a one-filter method. Median values of 2.0 and 0.4 mWL were measured for the indoor and outdoor concentrations, respectively. The average outdoor concentration was about an order of magnitude higher for wind directions between SE-SW than for SW-NW. On average, dwellings with double pane windows and/or concrete floors were found to have significantly higher radon concentrations than those with single pane windows and/or wooden floors. For the living room of a particular dwelling, 18 measurements were carried out. The data for this dwelling indicate a linear relation between the concentration indoors and outdoors with a slope of 3.8 +- 2.0. This unexpected behaviour is thought to be related to ventilation via the crawl space. Measurements of ventilation patterns and measurements of radon concentrations in the living room and the crawl space are consistent with this picture. (author)

  13. An education program about pelvic floor muscles improved women’s knowledge but not pelvic floor muscle function, urinary incontinence or sexual function: a randomised trial

    Directory of Open Access Journals (Sweden)

    Roberta Leopoldino de Andrade

    2018-04-01

    Full Text Available Question: Does an educational program with instructions for performing ‘the Knack’ improve voluntary contraction of the pelvic floor muscles, reduce reports of urinary incontinence, improve sexual function, and promote women’s knowledge of the pelvic floor muscles? Design: Randomised, controlled trial with concealed allocation, intention-to-treat analysis and blinded assessors. Participants: Ninety-nine women from the local community. Intervention: The experimental group (n = 50 received one lecture per week for 4 weeks, and instructions for performing ‘the Knack’. The control group (n = 49 received no intervention. Outcome measures: The primary outcome was maximum voluntary contraction of the pelvic floor muscles measured using manometry. Secondary outcomes were: ability to contract the pelvic floor muscles measured using vaginal palpation; severity of urinary incontinence measured by the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF scored from 0 to 21; self-reported sexual function; and knowledge related to the pelvic floor. Outcomes were measured at baseline and after 4 weeks. Results: The intervention did not significantly improve: maximum voluntary contraction (MD 2.7 cmH2O higher in the experimental group, 95% CI –0.5 to 5.9; ability to contract the pelvic floor muscles (RR 2.18, 95% CI 0.49 to 9.65; or self-reported severity of urinary incontinence (MD 1 point greater reduction in the experimental group, 95% CI –3 to 1. Sexual function did not significantly differ between groups, but very few of the women engaged in sexual activity during the study period. The educational program did, however, significantly increase women’s knowledge related to the location, functions and dysfunctions of the pelvic floor muscles, and treatment options. Conclusion: Education and teaching women to perform ‘the Knack’ had no significant effect on voluntary contraction of the pelvic floor muscles

  14. Hellish conditions at single-room occupancy hotels.

    Science.gov (United States)

    Foley, D

    1998-08-01

    Poor conditions exist in many of the commercial single-room occupancy (SRO) hotels for people who are HIV-positive. Living conditions are unsanitary, brutal, and dangerous, and occupants often experience harassment from the hotel owners and staff. Many of the occupants are drug abusers or are mentally incapacitated, and therefore may not have the ability to secure better housing. The situation in the California Suites, an SRO in Manhattan, is described.

  15. Integration of RFID and web service for assisted living.

    Science.gov (United States)

    Unluturk, Mehmet S; Kurtel, Kaan

    2012-08-01

    The number of people over 65 years old throughout most stable and prosperous countries in the world is increasing. Availability of their care in their own homes is imperative because of the economic reasons and their choices where to live (World Health Organization, Definition of an older or elderly person. http://www.who.int/healthinfo/survey/ageingdefnolder/en/ ; EQUIP-European Framework for Qualifications in Home Care Services for Older People, http://www.equip-project.com ; Salonen, 2009). "Recent advancement in wireless communications and electronics has enabled the development of low-cost sensor networks. The sensor networks can be utilized in various application areas." (Akyildiz, et al. 2002) These two statements show that there is a great promise in wireless technology and utilizing it in assisted living might be very beneficial to the elderly people. In this paper, we propose software architecture called Location Windows Service (LWS) which integrates the Radio Frequency Identification (RFID) technology and the web service to build an assisted living system for elderly people at home. This architecture monitors the location of elderly people without interfering in their daily activities. Location information messages that are generated as the elderly move from room to room indicate that the elderly person is fit and healthy and going about their normal life. The communication must be timely enough to follow elderly people as they move from room to room without missing a location. Unacknowledged publishing, subscription filtering and short location change messages are also included in this software model to reduce the network traffic in large homes. We propose some defense schemes being applied to the network environment of the assisted living system to prevent any external attacks.

  16. Impact of the wood combustion in an open fireplace on the air quality of a living room: Estimation of the respirable fraction.

    Science.gov (United States)

    Castro, A; Calvo, A I; Blanco-Alegre, C; Oduber, F; Alves, C; Coz, E; Amato, F; Querol, X; Fraile, R

    2018-07-01

    Presently, both in rural areas and in cities open fireplaces are still present and large quantities of wood are combusted every year. The present study aims to characterize aerosol size distribution, chemical composition and deposition in the human respiratory tract of particles emitted during the combustion of logs of oak in an open fireplace installed in the living room of a typical village house. CO 2 and CO levels and aerosol size distribution have been continuously monitored and a PM 10 sampler with two types of filters for chemical and microscopic analysis was also installed. The increment, between the operating periods and the indoor background, in the organic carbon and PM 10 concentration due to the use of the fireplace is 15.7±0.6 (mean±standard deviation) and 58.5±6.2μgm -3 , respectively. The two main polluting processes during the operation of the fireplace are the ignition with the subsequent refueling and the final cleaning of the residual ashes. In both phases mean values around 1800 particles cm -3 with CMD of 0.15μm were measured. However, while PM 10 levels of 130±120μgm -3 were estimated for the ignition stage, values of 200±200μgm -3 were obtained during the final cleaning step. Assessment conducted according to ISO standard 7708:1995, demonstrated that a person who stays in a living room when an open fireplace is lit will inhale, on average, 217μgm -3 and 283μgm -3 during the ignition and the refueling stages, respectively. Subsequent refueling proved to be much less polluting. The ashes removal can also be very polluting and dangerous to health if there are hidden small incandescent embers among the ashes (estimated PM 10 of 132μgm -3 ), reaching a CO 2 level of 1940ppm and a dangerous level of CO of 132ppm. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Pelvic floor dyssynergia: efficacy of biofeedback training.

    Science.gov (United States)

    Gadel Hak, Nabil; El-Hemaly, Mohamed; Hamdy, Emad; El-Raouf, Ahmed Abd; Atef, Ehab; Salah, Tarek; El-Hanafy, Ehab; Sultan, Ahmad; Haleem, Magdy; Hamed, Hala

    2011-03-01

    Paradoxical contraction of the pelvic floor during attempts to defaecate is described as pelvic floor dyssynergia (anismus). It is a behavioural disorder (no associated morphological or neurological abnormalities); consequently, biofeedback training has been recommended as a behavioural therapy for such a disorder. The aim of the present study was to evaluate long-term satisfaction of patients diagnosed with pelvic floor dyssynergia after biofeedback. Sixty patients (35 females and 25 males) with a mean age of 30±12years and a 4year duration of constipation were included. Forty-five patients had normal colonic transit and 15 patients had slow colonic transit. History, physical examination and barium enema were done to exclude constipation secondary to organic causes. Colonic and pelvic floor functions (colon-transit time, anorectal manometry, EMG and defaecography) were performed before and after biofeedback treatments. Patients were treated on a weekly basis with an average of (6±2) sessions. At the end of sessions, 55 out of 60 patients (91.6%) reported a subjectively overall improvement. Symptoms of dyschezia were reported less frequently after biofeedback. Age and gender were not predictive factors of outcome. No symptoms at initial assessment were predictive for patient's satisfaction but the only factor of predictive value was the diagnosis of anismus and the motivated patient who wanted to continue the sessions. Biofeedback remains a morbidity free, low-cost and effective outpatient therapy for well-motivated patients complaining of functional constipation and diagnosed as pelvic floor dyssynergia. Copyright © 2011 Arab Journal of Gastroenterology. Published by Elsevier Ltd. All rights reserved.

  18. Poultry rearing on perforated plastic floors and the effect on air quality, growth performance, and carcass injuries-Experiment 1: Thermal Comfort.

    Science.gov (United States)

    de Almeida, Eduardo Alves; Arantes de Souza, Lilian Francisco; Sant'Anna, Aline Cristina; Bahiense, Raphael Nogueira; Macari, Marcos; Furlan, Renato Luis

    2017-09-01

    The present study investigated the use of perforated plastic floors in the rearing of male and female poultry under thermal comfort conditions. The study was conducted in 2 climate chambers, in one was conventional poultry litter (wood shavings) and in the other was a perforated plastic floor. The experimental design was a completely randomized design with the factors wood shavings and plastic floor. In each chamber, the animals were divided into 16 experimental pens (8 with males and 8 with females) with a density of 12 birds/m2. The poultry rearing effect was evaluated in terms of air quality (% concentration of ammonia [NH3] and carbon dioxide [CO2]); broiler performance, e.g., weight gain (kg), feed intake (kg), feed conversion, carcass yield and parts (%), meat production (kg/m2), and viability (% of live birds at d 42); scores of hygiene and mobility; and injuries in the chest, hocks, and footpads. Treatments affected air quality, with higher concentrations of NH3 on d 42 (25 ppm vs. 2 ppm) and CO2 (1,400 ppm vs. 1,000 ppm) for wood shavings than for perforated plastic floor, respectively. Males showed a better performance (weight gain, feed intake and feed conversion) than females on d 42 in both floor types (wood shavings and plastic floor). Males reared on wood shavings showed a higher meet production (35.992 kg/m2) than females (32.257 kg/m2). On the plastic floor, males showed a better viability (100%) than females (94.05%), as well better meet production for males (38.55 kg·m-2) than females (31.64 kg/m2). There was no incidence of breast lesions in any of the studied systems. The birds reared on the plastic floor had better hygiene scores and lower hock injury rates than birds reared in the wood shavings chambers. The results of the present study show that the use of perforated plastic floors in chicken farming is an efficient method, which promotes a better-quality environment, superior production rates, and reduced incidence of injuries.

  19. 120 Years of U.S. Residential Housing Stock and Floor Space

    Energy Technology Data Exchange (ETDEWEB)

    Pinto de Moura, Maria C.; Smith, Steven J.; Belzer, David B.

    2015-08-11

    Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO2 emissions. Floor space is a major driver of building energy demand. This paper develops a historical time series of total residential floor space for 1891-2010 and examines the role of socio-economic drivers GDP, population and household size on floor space. Using primarily data from the U.S. Census Bureau, we develop new construction and vintage-disaggregated housing stock for three building types, and address various data inconsistency issues. An examination of the long-term relationship of GDP and total residential floor space shows a remarkably constant trend over the period. While population increases five times over the period, a 50% decrease in household size contributes towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. Total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years.

  20. Detection of 210Po on filter papers 16 years after use for the collection of short-lived radon progeny in a room

    International Nuclear Information System (INIS)

    Abu-Jarad, F.; Fazal-ur-Rehman

    2003-01-01

    Radon gas was allowed to accumulate in its radium source and then injected into a 36 m 3 test room, resulting in an initial radon concentration of 15 kBq m -3 . Filter papers were used to collect the short-lived radon progeny and thus to measure the Potential Alpha Energy Concentration (PAEC) in-situ in the year 1984 at different times and conditions according to the experimental design. The radon progeny collected on the filter papers were studied as a function of aerosol particle concentration ranging from 10 2 -10 5 particles cm -3 in three different experiments. The highest aerosol particle concentration was generated by indoor cigarette smoking. Those filters were stored after the experiment, and were used after 16 years to study the activity of the radon long-lived alpha emitter progeny, 210 Po (T 1/2 =138 days). This isotope is separated from the short-lived progeny by 210 Pb beta emitter with 22.3 years half-life. After 16 years' storage of these filters, each filter paper was sandwiched and wrapped between two CR-39 nuclear track detectors, to put the detectors in contact with the surfaces of different filters, for 337 days. Correlation between the PAEC measured using filter papers in the year 1984 and the activity of long-lived alpha emitter 210 Po on the same filter papers measured in the year 2000 were studied. The results of the 210 Po activity showed a very good correlation of 0.92 with the PAEC 16 years ago. The results also depict that the PAEC and 210 Po activity in indoor air increased with the increase of aerosol particle concentration, which shows the attachment of short-lived radon progeny with the aerosol particles. The experiment proves that indoor cigarette smoking is a major source of aerosol particles carrying radon progeny and, thus, indoor cigarette smoking is an additional source of internal radiation hazard to the occupants whether smoker or non-smoker

  1. Aarauerhof Hotel – Suiza

    Directory of Open Access Journals (Sweden)

    Dahinden, J.

    1975-05-01

    Full Text Available The hotel consists of basement, ground floor, first floor and other blocks of different heights, in which there is a total of 80 beds. So as to take advantage of the proximity to the railway station, in front of which the hotel is situated, the gastronomy section has been planned on the ground floor. On the first floor are the living rooms and conference rooms and the main one contains the fashion shops that extend over three floors. The first basement has a discotec; and in the second are situated the storage rooms and the installations of the building. The hotel is further completed by two storeys of subterranean parking space, situated below the square in front of the railway station.Está compuesto por sótanos, planta baja, planta primera y cuerpos elevados de distintas alturas, en los que se distribuyen un total de 80 camas. Para aprovechar la proximidad de la estación de ferrocarril, en cuya plaza se halla este hotel, se ha colocado la sección de gastronomía en la planta baja. En el primer nivel se encuentran las salas de estar y de reunión, y el principal aloja las tiendas de modas, que ocupan tres alturas. El primer sótano contiene una discoteca; y en el segundo se distribuyen los almacenes e instalaciones del edificio. El hotel se completa con dos plantas de aparcamiento subterráneo situadas bajo la plaza de la estación.

  2. Paleodictyon nodosum: A living fossil on the deep-sea floor

    Science.gov (United States)

    Rona, Peter A.; Seilacher, Adolf; de Vargas, Colomban; Gooday, Andrew J.; Bernhard, Joan M.; Bowser, Sam; Vetriani, Costantino; Wirsen, Carl O.; Mullineaux, Lauren; Sherrell, Robert; Frederick Grassle, J.; Low, Stephen; Lutz, Richard A.

    2009-09-01

    We report new in situ observations and laboratory studies of specimens of a small (diameter 2.4-7.5 cm) strikingly hexagonal form originally described from sedimented steps in a wall of the axial valley of the Mid-Atlantic Ridge (water depth 3430-3575 m) near 26°N, 45°W that appears to be identical to the iconic form Paleodictyon nodosum described as a trace fossil from Eocene flysch deposits at sites in Europe and Wales. Our findings follow: The form is apparently agglutinated in sea floor sediment (a veneer of calcareous lutite over red metalliferous sediment) and consists of three equidistant rows of tiny holes (diameter ˜1 mm) that intersect at an angle of 120° and continuously connect through vertical shafts (length 2-3 mm) with an underlying horizontal network of tubes or tunnels identical with the fossil form. The number of rows of holes and spacing of rows increase with overall diameter of the form indicative of organic growth. The form is shaped like a shield surrounded by a lip and moat with surface relief (˜0.5 cm) that is absent in the fossil form. The surface relief exposes the underlying red sediment and may have been produced either by excavation (constructional origin) or by infaunal growth (body form). Protoplasm is absent in recovered specimens, as indicated by negative results of staining techniques, explained by either initial absence or loss. Genetic sequencing of material from the form identified different foraminifera that had settled on the pattern of holes which acts as a baffle to trap organic matter. Models in flume tanks show that the shield-like form deflects flow of ocean currents into a self-ventilating structure capable of aerating and of circulating organic particles through the tubes or tunnels. Microbial counting techniques indicated background abundances within and outside the form. We come to two alternative interpretations of the findings resolvable with further studies: The modern P. nodosum is a burrow consistent with

  3. Effects of dietary coarsely ground corn and 3 bedding floor types on broiler live performance, litter characteristics, gizzard and proventriculus weight, and nutrient digestibility.

    Science.gov (United States)

    Xu, Y; Lin, Y M; Stark, C R; Ferket, P R; Williams, C M; Brake, J

    2017-07-01

    The effects of zero or 50% dietary coarsely ground corn (CC) in pelleted and screened grower and finisher diets on broilers reared on 3 bedding floor types (plastic net [NET], new pine wood shavings litter [NEW], or old pine wood shavings litter [OLD]) on broiler live performance, litter characteristics, gizzard and proventriculus weight, and apparent ileal digestibility (AID) were studied in a 2 × 3 factorial arrangement of treatments. Fine corn was produced with a hammermill (271 μm) and CC with a roller mill (1145 μm). Utilization of CC reduced milling cost by 9.47 cents per MT with similar nutrient content of screened pellets. The 50% CC treatment exhibited improved (P ≤ 0.05) feed intake at 42 d (2.5%) and 49 d (3.0%), and BW (5.4%) and FCR from 28 d (1.4%). Birds on NEW litter exhibited improved (P litter birds exhibited increased (P ≤ 0.05) gizzard weight at 28 d and 49 d and decreased proventriculus weight as compared to NET at 49 days. The 50% CC treatment exhibited decreased (P ≤ 0.05) litter moisture at 35 and 42 d, litter N at 35 and 49 d, and litter pH at 49 days. OLD litter birds exhibited greater (P litter N at 14, 35, and 49 d, as well as litter moisture, pH, and ammonia concentration at 49 days. The 50% CC group also exhibited improved AID of nitrogen (P Broilers fed pelleted and screened diets containing 50% CC exhibited improved live performance and reduced litter moisture while use of NEW litter resulted in a somewhat similar effect, which indicated that consumption of NEW litter also facilitated gastric development and function. © 2017 Poultry Science Association Inc.

  4. 76 FR 7098 - Dealer Floor Plan Pilot Program

    Science.gov (United States)

    2011-02-09

    ... Plan Pilot Program AGENCY: U.S. Small Business Administration (SBA). ACTION: Program implementation with request for comments. SUMMARY: SBA is introducing a new Dealer Floor Plan Pilot Program to make... Plan Pilot Program was created in the Small Business Jobs Act of 2010. Under the new Dealer Floor Plan...

  5. 49 CFR 38.99 - Floors, steps and thresholds.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.99 Section 38.99 Transportation Office of the Secretary of Transportation AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY SPECIFICATIONS FOR TRANSPORTATION VEHICLES Commuter Rail Cars and Systems § 38.99 Floors, steps and thresholds...

  6. "Help Me Pull That Cursor" A Collaborative Interactive Floor Enhancing Community Interaction

    Directory of Open Access Journals (Sweden)

    Peter Krogh

    2004-05-01

    Full Text Available In this paper we describe the development, experiments and evaluation of the iFloor, an interactive floor prototype installed at the local central municipality library. The primary purpose of the iFloor prototype is to support and stimulate community interaction between collocated people. The context of the library demands that any user can walk up and use the prototype without any devices or prior introduction. To achieve this, the iFloor proposes innovative interaction (modes/paradigms/patterns for floor surfaces through the means of video tracking. Browsing and selecting content is done in a collaborative process and mobile phones are used for posting messages onto the floor. The iFloor highlights topics on social issues of ubiquitous computing environments in public spaces, and provides an example of how to exploit human spatial movements, positions and arrangements in interaction with computers.

  7. A Method of Assembling Wall or Floor Elements

    DEFF Research Database (Denmark)

    2002-01-01

    The invention relates to a method of constructing, at the site of use, a building wall (1) or a building floor (1) using a plurality of prefabricated concrete or lightweight concrete plate-shaped wall of floor elements (10), in particular cast elements, which have a front side and a rear side...

  8. 120 Years of U.S. Residential Housing Stock and Floor Space.

    Directory of Open Access Journals (Sweden)

    Maria Cecilia P Moura

    Full Text Available Residential buildings are a key driver of energy consumption and also impact transportation and land-use. Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO2 emissions, with floor space a major driver of building energy demands. In this work a consistent, vintage-disaggregated, annual long-term series of U.S. housing stock and residential floor space for 1891-2010 is presented. An attempt was made to minimize the effects of the incompleteness and inconsistencies present in the national housing survey data. Over the 1891-2010 period, floor space increased almost tenfold, from approximately 24,700 to 235,150 million square feet, corresponding to a doubling of floor space per capita from approximately 400 to 800 square feet. While population increased five times over the period, a 50% decrease in household size contributed towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. GDP and total floor space show a remarkably constant growth trend over the period and total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years, decoupling only within the last decade.

  9. There is more to life than risk avoidance - elderly people's experiences of falls, fall-injuries and compliant flooring.

    Science.gov (United States)

    Gustavsson, Johanna; Jernbro, Carolina; Nilson, Finn

    2018-12-01

    Falls are the most common cause of injury in all ages and are especially difficult to prevent among residential care residents. Compliant flooring that absorbs energy generated within the fall, has been proposed as a measure to prevent fall-injury, however little is known regarding the implementation aspects in clinical settings. The aim of this study is to explore the experiences of falls, the risk of fall-injury, prevention in general and specifically compliant flooring as an injury preventative measure amongst frail elderly people living in a residential care facility with compliant flooring. Through this, generate a theory that further explains the underlying barriers of active prevention amongst elderly people. We used the grounded theory method and conducted semi-structured in-depth interviews with eight elderly people in residential care (data collected between February and December 2017). The identified categories were Falling as a part of life, Fearing the consequences and A wish to prevent falls and injuries. Through the results it was clear that There is more to life than risk avoidance, permeated the interviews, therefore forming the grounded theory. The interviewees viewed falls as something common and normal, and were uninterested in focusing on the risk of falls. Although they wanted to prevent falls, it was often difficult to integrate preventative measures into their everyday life. They embraced the idea of an injury-reducing compliant flooring, however their main interests lay elsewhere, preferring to focus on social interaction and issues concerning daily activities. The theory generated in this paper proposes explanations on the obstacles of implementing fall prevention measures in an elderly frail population. The findings give insights as to why interest and compliance for active fall prevention measures are low. We conclude that complaint flooring, from the perspective of the residents, can work well in residential care.

  10. Vivienda unifamiliar en Aravaca Madrid – España

    Directory of Open Access Journals (Sweden)

    Martín-Artajo, Alberto

    1976-06-01

    Full Text Available This construction, made up of three storeys and basement was situated in one of the corners of the plot and the rest of the area could thus be used for building the following: swimming pool; tennis court; a small vegetable garden with hothouse and a big garden. The basement comprises: a garage with three parking places; boiler room; and living quarters for the staff; further, gymnasium with dressing rooms and sauna; a bar room with wine cellar; and a chapel. On the ground floor are situated: drawing room, living room, dining room and library; kitchen; larder; laundry and ironing room; staff bedroom and a terrace-drying room. The first floor consists of: four bedrooms each of which has a dressing room and bath room; parents bedroom with dressing room and bath room. The top floor holds: a hall for trophies plus an office room; play room; a study. The building is a point structure with screen walls in the basement and is on the outside entirely covered with tiles. The chimneys, the marked wings, as well as the sloping walls form a harmonious unit with a strong personality.El edificio, de tres plantas y sótano, se situó en uno de los extremos del terreno, aprovechándose el resto de la parcela para distribuir: una piscina; una pista de tenis; una pequeña huerta con invernadero, y amplias zonas ajardinadas. El sótano alberga: el garaje de tres plazas; el cuarto de calderas, y una vivienda para el servicio. El resto de la planta la ocupan: un gimnasio con vestuarios y sauna; una pequeña taberna con bodega; una capilla; una cámara acorazada, y un trastero. En la planta baja se sitúan: la zona noble, compuesta por salón, estar, comedor y biblioteca; y la zona de servicio, con oficio, cocina, despensa, lavadero y cuarto de plancha, dormitorio de servicio, y una terraza-tendedero. La planta primera consta de: cuatro dormitorios, cada uno con vestidor y cuarto de baño completo; y el dormitorio de padres, con vestidor, cuarto de ba

  11. Floor-fractured craters on Ceres and implications for interior processes

    Science.gov (United States)

    Buczkowski, Debra; Schenk, Paul M.; Scully, Jennifer E. C.; Park, Ryan; Preusker, Frank; Raymond, Carol; Russell, Christopher T.

    2016-10-01

    Several of the impact craters on Ceres have patterns of fractures on their floors. These fractures appear similar to those found within a class of lunar craters referred to as Floor-Fractured Craters (FFCs) [Schultz, 1976].Lunar FFCs are characterized by anomalously shallow floors cut by radial, concentric, and/or polygonal fractures, and have been classified into crater classes, Types 1 through 6, based on their morphometric properties [Schultz, 1976; Jozwiak et al, 2012, 2015]. Models for their formation have included both floor uplift due to magmatic intrusion below the crater or floor shallowing due to viscous relaxation. However, the observation that the depth versus diameter (d/D) relationship of the FFCs is distinctly shallower than the same association for other lunar craters supports the hypotheses that the floor fractures form due to shallow magmatic intrusion under the crater [Jozwiak et al, 2012, 2015].FFCs have also been identified on Mars [Bamberg et al., 2014]. Martian FFCs exhibit morphological characteristics similar to the lunar FFCs, and analyses suggest that the Martian FCCs also formed due to volcanic activity, although heavily influenced by interactions with groundwater and/or ice.We have cataloged the Ceres FFCs according to the classification scheme designed for the Moon. Large (>50 km) Ceres FFCs are most consistent with Type 1 lunar FFCs, having deep floors, central peaks, wall terraces, and radial and/or concentric fractures. Smaller craters on Ceres are more consistent with Type 4 lunar FFCs, having less-pronounced floor fractures and a v-shaped moats separating the wall scarp from the crater interior.An analysis of the d/D ratio for Ceres craters shows that, like lunar FFCs, the Ceres FFCs are anomalously shallow. This suggests that the fractures on the floor of Ceres FFCs may be due the intrusion of a low-density material below the craters that is uplifting their floors. While on the Moon and Mars the intrusive material is hypothesized

  12. Comparison between dynamic cystocolpoproctography and dynamic pelvic floor MRI: pros and cons: which is the "functional" examination for anorectal and pelvic floor dysfunction?

    Science.gov (United States)

    Maglinte, Dean D T; Hale, Douglass S; Sandrasegaran, Kumar

    2013-10-01

    "Functional" imaging of anorectal and pelvic floor dysfunction has assumed an important role in the diagnosis and management of these disorders. Although defecography has been widely practiced for decades to evaluate the dynamics of rectal emptying, debate concerning its clinical relevance, how it should be done and interpreted continues. Due to the recognition of the association of defecatory disorders with pelvic organ prolapse in women, the need to evaluate the pelvic floor as a unit has arisen. To meet this need, defecography has been extended to include not only evaluation of defecation disorders but also the rest of the pelvic floor by opacifying the small bowel, vagina, and the urinary bladder. The term "dynamic cystocolpoproctography" (DCP) has been appropriately applied to this examination. Rectal emptying performed with DCP provides the maximum stress to the pelvic floor resulting in complete levator ani relaxation. In addition to diagnosing defecatory disorders, this method of examination demonstrates maximum pelvic organ descent and provides organ-specific quantification of organ prolapse, information that is only inferred by means of physical examination. It has been found to be of clinical value in patients with defecation disorders and the diagnosis of associated prolapse in other compartments that are frequently unrecognized by history taking and the limitations of physical examination. Pelvic floor anatomy is complex and DCP does not show the anatomical details pelvic magnetic resonance imaging (MRI) provides. Technical advances allowing acquisition of dynamic rapid MRI sequences has been applied to pelvic floor imaging. Early reports have shown that pelvic MRI may be a useful tool in pre-operative planning of these disorders and may lead to a change in surgical therapy. Predictions of hypothetical increase cancer incidence and deaths in patients exposed to radiation, the emergence of pelvic floor MRI in addition to questions relating to the

  13. Chronic pelvic floor dysfunction.

    Science.gov (United States)

    Hartmann, Dee; Sarton, Julie

    2014-10-01

    The successful treatment of women with vestibulodynia and its associated chronic pelvic floor dysfunctions requires interventions that address a broad field of possible pain contributors. Pelvic floor muscle hypertonicity was implicated in the mid-1990s as a trigger of major chronic vulvar pain. Painful bladder syndrome, irritable bowel syndrome, fibromyalgia, and temporomandibular jaw disorder are known common comorbidities that can cause a host of associated muscular, visceral, bony, and fascial dysfunctions. It appears that normalizing all of those disorders plays a pivotal role in reducing complaints of chronic vulvar pain and sexual dysfunction. Though the studies have yet to prove a specific protocol, physical therapists trained in pelvic dysfunction are reporting success with restoring tissue normalcy and reducing vulvar and sexual pain. A review of pelvic anatomy and common findings are presented along with suggested physical therapy management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Smart Floor with Integrated Triboelectric Nanogenerator As Energy Harvester and Motion Sensor.

    Science.gov (United States)

    He, Chuan; Zhu, Weijun; Chen, Baodong; Xu, Liang; Jiang, Tao; Han, Chang Bao; Gu, Guang Qin; Li, Dichen; Wang, Zhong Lin

    2017-08-09

    A smart floor is demonstrated by integrating a square-frame triboelectric nanogenerator (SF-TENG) into a standard wood floor. The smart floor has two working modes based on two pairs of triboelectric materials: one is purposely chosen polytetrafluoroethylene films and aluminum (Al) balls, and the other is the floor itself and the objects that can be triboelectrically charged, such as basketball, shoe soles, and Scotch tape, etc. Utilizing the Al balls enclosed inside shallow boxes, the smart floor is capable of harvesting vibrational energy and, hence, provides a nonintrusive way to detect sudden falls in elderly people. In addition, when the basketball is bounced repeatedly on the floor, the average output voltage and current are 364 ± 43 V and 9 ± 1 μA, respectively, and 87 serially connected light-emitting diodes can be lit up simultaneously. Furthermore, the friction between the triboelectrically chargeable objects and the floor can also induce an alternating current output in the external circuit without the vibration of the Al balls. Normal human footsteps on the floor produce a voltage of 238 ± 17 V and a current of 2.4 ± 0.3 μA. Therefore, this work presents a smart floor with built-in SF-TENG without compromising the flexibility and stability of the standard wood floor and also demonstrates a way to harvest ambient energy solely by using conventional triboelectric materials in our daily life.

  15. How to live CO{sub 2} neutral in bathrooms, offices, living rooms and kitchens?

    Energy Technology Data Exchange (ETDEWEB)

    Berker, Thomas; Gansmo, Helen Joesok

    2010-07-01

    this task by studies showing that and how human action is embedded in both everyday practices and socio-technical networks. Here we propose to focus on mainly four areas of human activity: relaxing/entertaining (the living room), eating/preparing food (the kitchen), personal/environmental cleanliness (the bath), and clerical work (the office).(We are aware that these areas are neither mutually exclusive nor do they cover all greenhouse gas emitting activities in everyday life. Especially transport deserves a corresponding treatment but is not covered by the funding agency of this workshop.) These areas each consist of activities more directly bound to instrumental concerns, for example the production/reproduction cycle, and the provision of nutrition and basic hygiene. At least as important, however, is that these are some of the most important arenas where social distinction, meaning production and identity formation is taking place. Based on this research and our own studies of the meaning of aesthetics in domestic settings we aim at both broadening the theoretical horizon and deepening our understanding of individual practices and socio-technical networks. Additionally, the development of nonreductionist research on mediations and mediators between micro and macro perspectives on CO{sub 2} emissions is in dire need. (Author)

  16. A prospective study of floor surface, shoes, floor cleaning and slipping in US limited-service restaurant workers.

    Science.gov (United States)

    Verma, Santosh K; Chang, Wen Ruey; Courtney, Theodore K; Lombardi, David A; Huang, Yueng-Hsiang; Brennan, Melanye J; Mittleman, Murray A; Ware, James H; Perry, Melissa J

    2011-04-01

    Slips and falls are a leading cause of injury at work. Few studies, however, have systematically examined risk factors of slipping outside the laboratory environment. This study examined the association between floor surface characteristics, slip-resistant shoes, floor cleaning frequency and the risk of slipping in limited-service restaurant workers. 475 workers from 36 limited-service restaurants from three major chains in six states in the USA were recruited to participate in a prospective cohort study of workplace slipping. Kitchen floor surface roughness and coefficient of friction (COF) were measured in eight working areas and then averaged within each restaurant. The use of slip-resistant shoes was determined by examining the participant's shoes and noting the presence of a 'slip-resistant' marking on the sole. Restaurant managers reported the frequency of daily kitchen floor cleaning. Participants reported their slip experience and work hours weekly for up to 12 weeks. The survey materials were made available in three languages: English, Spanish and Portuguese. The associations between rate of slipping and risk factors were assessed using a multivariable negative binomial generalised estimating equation model. The mean of individual slipping rate varied among the restaurants from 0.02 to 2.49 slips per 40 work hours. After adjusting for age, gender, BMI, education, primary language, job tenure and restaurant chain, the use of slip-resistant shoes was associated with a 54% reduction in the reported rate of slipping (95% CI 37% to 64%), and the rate of slipping decreased by 21% (95% CI 5% to 34%) for each 0.1 increase in the mean kitchen COF. Increasing floor cleaning frequency was significantly associated with a decreasing rate of slipping when considered in isolation but not after statistical adjustment for other factors. These results provide support for the use of slip-resistant shoes and measures to increase COF as preventive interventions to reduce slips

  17. Lead exposures from varnished floor refinishing.

    Science.gov (United States)

    Schirmer, Joseph; Havlena, Jeff; Jacobs, David E; Dixon, Sherry; Ikens, Robert

    2012-01-01

    We evaluated the presence of lead in varnish and factors predicting lead exposure from floor refinishing and inexpensive dust suppression control methods. Lead in varnish, settled dust, and air were measured using XRF, laboratory analysis of scrape and wipe samples, and National Institute for Occupational Safety and Health (NIOSH) Method 7300, respectively, during refinishing (n = 35 homes). Data were analyzed using step-wise logistic regression. Compared with federal standards, no lead in varnish samples exceeded 1.0 mg/cm(2), but 52% exceeded 5000 ppm and 70% of settled dust samples after refinishing exceeded 40 μg/ft(2). Refinishing pre-1930 dwellings or stairs predicted high lead dust on floors. Laboratory analysis of lead in varnish was significantly correlated with airborne lead (r = 0.23, p = 0.014). Adding dust collection bags into drum sanders and HEPA vacuums to edgers and buffers reduced mean floor lead dust by 8293 μg Pb/ft(2) (pairborne lead exposures to less than 50 μg/m(3). Refinishing varnished surfaces in older housing produces high but controllable lead exposures.

  18. Dermatophagoides pteronyssinus (Trouessart, 1897) in mattress and floor dust in a temperate climate (Acari : Pyroglyphidae)

    NARCIS (Netherlands)

    Bronswijk, van J.E.M.H.

    1973-01-01

    The arthropod fauna of mattress dust, bedroom dust and living-room dust was sampled during a 1-year period in a center for asthmatic children (near Nijmegen, The Netherlands) with the aid of a vacuum cleaner, Berlese funnels and a flotation method. Dermatophagoides pteronyssinus was most abundant;

  19. Dance floor mechanical properties and dancer injuries in a touring professional ballet company.

    Science.gov (United States)

    Hopper, Luke S; Allen, Nick; Wyon, Matthew; Alderson, Jacqueline A; Elliott, Bruce C; Ackland, Timothy R

    2014-01-01

    The mechanical properties of the floors used by dancers have often been suggested to be associated with injury, yet limited etiological evidence is available to support this hypothesis. The dance floors at three theatres regularly used by a touring professional ballet company were mechanically quantified with the aim of comparing floor properties with injury incidence in dancers. Cross sectional. Test points on the floors were quantified in accordance with European Sports Surface Standard protocols for force reduction. Injuries and associated variables occurring within the ballet company dancers during activity on the three floors were recorded by the company's medical staff. An injury was recorded if a dancer experienced an incident that restricted the dancer from performing all normal training or performance activities for a 24 h period. Injuries were delimited to those occurring in the lower limbs or lumbar region during non-lifting tasks. Floor construction varied between venues and a range of floor mechanical properties were observed. None of the floors complied with the range of force reduction values required by the European Sport Surface Standards. The highest injury rate was observed on the floor with the greatest variability of force reduction magnitudes. No difference in injury frequency was observed between the venues with the highest and lowest mean force reduction magnitudes. Professional dancers can be required to perform on floors that may be inadequate for safe dance practice. Intra-floor force reduction variability may have a stronger association with injury risk than mean floor force reduction magnitude. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. RadShield: semiautomated shielding design using a floor plan driven graphical user interface.

    Science.gov (United States)

    DeLorenzo, Matthew C; Wu, Dee H; Yang, Kai; Rutel, Isaac B

    2016-09-08

    The purpose of this study was to introduce and describe the development of RadShield, a Java-based graphical user interface (GUI), which provides a base design that uniquely performs thorough, spatially distributed calculations at many points and reports the maximum air-kerma rate and barrier thickness for each barrier pursuant to NCRP Report 147 methodology. Semiautomated shielding design calculations are validated by two approaches: a geometry-based approach and a manual approach. A series of geometry-based equations were derived giv-ing the maximum air-kerma rate magnitude and location through a first derivative root finding approach. The second approach consisted of comparing RadShield results with those found by manual shielding design by an American Board of Radiology (ABR)-certified medical physicist for two clinical room situations: two adjacent catheterization labs, and a radiographic and fluoroscopic (R&F) exam room. RadShield's efficacy in finding the maximum air-kerma rate was compared against the geometry-based approach and the overall shielding recommendations by RadShield were compared against the medical physicist's shielding results. Percentage errors between the geometry-based approach and RadShield's approach in finding the magnitude and location of the maximum air-kerma rate was within 0.00124% and 14 mm. RadShield's barrier thickness calculations were found to be within 0.156 mm lead (Pb) and 0.150 mm lead (Pb) for the adjacent catheteriza-tion labs and R&F room examples, respectively. However, within the R&F room example, differences in locating the most sensitive calculation point on the floor plan for one of the barriers was not considered in the medical physicist's calculation and was revealed by the RadShield calculations. RadShield is shown to accurately find the maximum values of air-kerma rate and barrier thickness using NCRP Report 147 methodology. Visual inspection alone of the 2D X-ray exam distribution by a medical physicist may not

  1. Experiences of incontinence and pelvic floor muscle training after gynaecologic cancer treatment.

    Science.gov (United States)

    Lindgren, Anna; Dunberger, G; Enblom, A

    2017-01-01

    The purpose of the present study is to describe how gynaecological cancer survivors (GCS) experience incontinence in relation to quality of life, their possibilities for physical activity and exercise and their perceptions and experiences of pelvic floor muscle training. This qualitative interview content analysis study included 13 women (48-82 age) with urinary (n = 10) or faecal (n = 3) incontinence after radiation therapy (n = 2), surgery (n = 5) and surgery and radiation therapy (n = 6) for gynaecological cancer, 0.5-21 years ago. Symptoms related to incontinence and restrictions in daily activities reduced physical quality of life. Emotions related to incontinence reduced psychological quality of life and social and existential quality of life, due to restrictions in activity and feelings of exclusion. Practical and mental strategies for maintaining quality of life were described, such as always bringing a change of clothes and accepting the situation. Possibilities for sexual and physical activity as well as exercise were also restricted by incontinence. The women had little or no experience of pelvic floor muscle training but have a positive attitude towards trying it. They also described a lack of information about the risk of incontinence. The women were willing to spend both money and time on an effective treatment for their incontinence. Nine out of 10 were willing to spend at least 7 h a week. GCS experienced that incontinence reduced quality of life and limited possibilities for sexual and physical activity as well as exercise. Coping strategies, both practical and emotional, facilitated living with incontinence. The women had a positive attitude towards pelvic floor muscle training. Lack of information had a negative impact on their way of dealing with the situation.

  2. Awareness and timing of pelvic floor muscle contraction, pelvic exercises and rehabilitation of pelvic floor in lifelong premature ejaculation: 5 years experience

    Directory of Open Access Journals (Sweden)

    Giuseppe La Pera

    2014-06-01

    Full Text Available Objectives: To assess the cure rate of patients with premature ejaculation who underwent a treatment involving: 1 awareness of the pelvic floor muscles 2 learning the timing of execution and maintenance of contraction of the pelvic floor muscles during the sensation of the pre-orgasmic phase 3 pelvic floor rehabilitation (bio feed back, pelvic exercises and electrostimulation. Materials and methods: We recruited 78 patients with lifelong premature ejaculation who completed the training. The patients were informed of the role of the pelvic floor. They were taught to carry out the execution and maintenance of contraction of the pelvic floor muscles during the sensation of the pre-orgasmic phase to control the ejaculatory reflex. In order to improve the awareness, the tone and the endurance of the pelvic floor muscles, patients were treated with the rehabilitation of pelvic floor (RPF consisting mainly in biofeedback, pelvic exercises and in some cases also in electro-stimulation (ES. The training was carried out for a period of about 2-6 months with an average of 2-5 visits per cycle. Results: 54% of patients who completed the training were cured of premature ejaculation and learned over time to be able to postpone the ejaculation reflex. In a subgroup of 26 patients was also measured the IELT which on the average increased from < 2 minutes to >10 minutes. The best results occurred mainly in patients aged less than 35 where the cure rate was 65%. There were no side effects. Conclusions: In this study, approximately half of patients with premature ejaculation were cured after applying the above treatment.This therapy, necessitates a fairly long period of time (2-6 months and a great commitment on the part of the patient, nevertheless it can be a valid and effective treatment for patients with premature ejaculation. This treatment makes the patient independent in that he is not bound to specific times for taking medication. Furthermore there are no

  3. The architectural foundations for agent-based shop floor control

    DEFF Research Database (Denmark)

    Langer, Gilad; Bilberg, Arne

    1998-01-01

    simulation and cell controlenabling technologies. In order to continuethis research effortnew concepts and theories for shop floor control are investigated.This paper reviews the multi-agent concept aimed at investigatingits potential use in shop floor control systems. The paper willalso include a survey...

  4. Detection of {sup 210}Po on filter papers 16 years after use for the collection of short-lived radon progeny in a room

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F. E-mail: falah.abujarad@aramco.com; Fazal-ur-Rehman

    2003-07-01

    Radon gas was allowed to accumulate in its radium source and then injected into a 36 m{sup 3} test room, resulting in an initial radon concentration of 15 kBq m{sup -3}. Filter papers were used to collect the short-lived radon progeny and thus to measure the Potential Alpha Energy Concentration (PAEC) in-situ in the year 1984 at different times and conditions according to the experimental design. The radon progeny collected on the filter papers were studied as a function of aerosol particle concentration ranging from 10{sup 2}-10{sup 5} particles cm{sup -3} in three different experiments. The highest aerosol particle concentration was generated by indoor cigarette smoking. Those filters were stored after the experiment, and were used after 16 years to study the activity of the radon long-lived alpha emitter progeny, {sup 210}Po (T{sub 1/2}=138 days). This isotope is separated from the short-lived progeny by {sup 210}Pb beta emitter with 22.3 years half-life. After 16 years' storage of these filters, each filter paper was sandwiched and wrapped between two CR-39 nuclear track detectors, to put the detectors in contact with the surfaces of different filters, for 337 days. Correlation between the PAEC measured using filter papers in the year 1984 and the activity of long-lived alpha emitter {sup 210}Po on the same filter papers measured in the year 2000 were studied. The results of the {sup 210}Po activity showed a very good correlation of 0.92 with the PAEC 16 years ago. The results also depict that the PAEC and {sup 210}Po activity in indoor air increased with the increase of aerosol particle concentration, which shows the attachment of short-lived radon progeny with the aerosol particles. The experiment proves that indoor cigarette smoking is a major source of aerosol particles carrying radon progeny and, thus, indoor cigarette smoking is an additional source of internal radiation hazard to the occupants whether smoker or non-smoker.

  5. Compliant flooring for fall injury prevention in long-term care

    OpenAIRE

    Lachance, Chantelle

    2017-01-01

    A promising strategy for reducing the incidence and severity of fall-related injuries in long-term care (LTC) is to decrease the ground surface stiffness, and the subsequent forces applied to the body parts at impact, through installation of compliant flooring. Evidence about the feasibility of compliant flooring in LTC is extremely limited. My PhD research addresses this gap by conducting a comprehensive, multimethod evaluation of compliant flooring. Specifically, I investigate the feasibili...

  6. Thermal analysis of a double layer phase change material floor

    International Nuclear Information System (INIS)

    Jin Xing; Zhang Xiaosong

    2011-01-01

    Phase change materials (PCMs) can be used to shift the cooling or heating load from the peak period to the off-peak period. In this paper, a new double layer phase change material (PCM) floor is put forward. The two layers of PCM have different melting temperature. The system is used to store heat or cold energy in the off-peak period and release them in the peak period during heating or cooling. According to the numerical model built in this paper, the thermal performances of the floor are analyzed. The results show that the optimal melting temperatures of PCMs exist. The fluctuations of the floor surface temperatures and the heat fluxes will be reduced and the system still can provide a certain amount of heat or cold energy after the heat pump or chiller has been turned off for a long time. Compared to the floor without PCM, the energy released by the floor with PCM in peak period will be increased by 41.1% and 37.9% during heating and cooling when the heat of fusion of PCM is 150 kJ/kg. - Highlights: → A new double layer phase change material floor is put forward. → The system is used to store heat or cold energy in the off-peak period and release them in the peak period during heating or cooling. → The optimal melting temperatures of PCMs in the system exist. → The heat and cold energy released by the floor with PCM in peak period can be increased by 41.1% and 37.9%.

  7. Vivienda unifamiliar, en Holanda

    Directory of Open Access Journals (Sweden)

    Salomonson, Hein Salomonson

    1968-04-01

    Full Text Available This house has a ground and a top floor. The ground floor comprises an ample entry zone, the living space, with large rooms, and a service section, including kitchen, garage and other ancillary facilities. The top floor involves the sleeping quarters. It is possible to enlarge the capacity of the various rooms of both floors, by incorporating the terraces. This was a necessary requirement, owing to the intensive social life that its occupants anticipate. Basic materials used include steel windows and external doors, travertino floors in the hall, white painted brickwork for the external walls and Oregon pinewood for the internal partition.Consta de dos plantas: baja y primera. La baja comprende: una amplia zona de ingreso; la zona de estar, con amplios salones; la zona de servicio, con la cocina y dependencias anejas, etc.; y el garaje. La planta superior está ocupada por la zona de dormitorios. Existe la posibilidad de ampliar la capacidad de las diferentes habitaciones de ambas plantas, mediante la incorporación de las terrazas exteriores. Esta condición era necesaria, dada la gran vida de relación prevista para la zona noble. Materiales fundamentales: carpintería exterior metálica, de acero; solados de travertine en el hall; fábrica de ladrillo pintada de blanco en los cerramientos y pino de Oregon en el exterior.

  8. Smart Offices and Intelligent Decision Rooms

    Science.gov (United States)

    Ramos, Carlos; Marreiros, Goreti; Santos, Ricardo; Freitas, Carlos Filipe

    Nowadays computing technology research is focused on the development of Smart Environments. Following that line of thought several Smart Rooms projects were developed and their appliances are very diversified. The appliances include projects in the context of workplace or everyday living, entertainment, play and education. These appliances envisage to acquire and apply knowledge about the environment state in order to reason about it so as to define a desired state for its inhabitants and perform adaptation adaptation to these desires and therefore improving their involvement and satisfaction with that environment.

  9. Study of the radiation scattered and produced by concrete shielding of radiotherapy rooms and its effects on equivalent doses in patients' organs

    International Nuclear Information System (INIS)

    Braga, K.L.; Rebello, W.F.; Andrade, E.R.; Gavazza, S.; Medeiros, M.P.C.; Mendes, R.M.S.; Gomes, R.G.; Silva, M.G.; Thalhofer, J.L.; Silva, A.X.; Santos, R.F.G.

    2015-01-01

    Within a radiotherapy room, in addition to the primary beam, there is also secondary radiation due to the leakage of the accelerator head and the radiation scattering from room objects, patient and even the room's shielding itself, which is projected to protect external individuals disregarding its effects on the patient. This work aims to study the effect of concrete shielding wall over the patient, taking into account its contribution on equivalent doses. The MCNPX code was used to model the linear accelerator Varian 2100/2300 C/D operating at 18MeV, with MAX phantom representing the patient undergoing radiotherapy treatment for prostate cancer following Brazilian Institute of Cancer four-fields radiation application protocol (0°, 90°, 180° and 270°). Firstly, the treatment was patterned within a standard radiotherapy room, calculating the equivalent doses on patient's organs individually. In a second step, this treatment was modeled withdrawing the walls, floor and ceiling from the radiotherapy room, and then the equivalent doses calculated again. Comparing these results, it was found that the concrete has an average shielding contribution of around 20% in the equivalent dose on the patient's organs. (author)

  10. DESIGN AND MANUFACTURING OF MODULAR PARQUET FLOORING IN INDUSTRIAL SYSTEM

    Directory of Open Access Journals (Sweden)

    Ivan CISMARU

    2014-09-01

    Full Text Available The paper submits constructive options and methods to design and manufacture modular parquet flooring, as well as fastening methods in constructions. Likewise, it presents the branches of civil engineering where modular parquet flooring may be turned to profit – industrial buildings, company premises or residential premises. The turn towards the achievement of private constructions, such as individual houses, led to losing control of the modular system applied in defining the inner sizes of the constructions and implicitly to the apparition of dimensional incompatibilities between the parquet flooring and the built spaces. The paper sets out (to solve by an individualized design procedure to achieve modular parquet flooring in industrial system, in correspondence with the sizes of the inner spaces afferent to the constructions.

  11. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  12. Room temperature excitation spectroscopy of single quantum dots

    Directory of Open Access Journals (Sweden)

    Christian Blum

    2011-08-01

    Full Text Available We report a single molecule detection scheme to investigate excitation spectra of single emitters at room temperature. We demonstrate the potential of single emitter photoluminescence excitation spectroscopy by recording excitation spectra of single CdSe nanocrystals over a wide spectral range of 100 nm. The spectra exhibit emission intermittency, characteristic of single emitters. We observe large variations in the spectra close to the band edge, which represent the individual heterogeneity of the observed quantum dots. We also find specific excitation wavelengths for which the single quantum dots analyzed show an increased propensity for a transition to a long-lived dark state. We expect that the additional capability of recording excitation spectra at room temperature from single emitters will enable insights into the photophysics of emitters that so far have remained inaccessible.

  13. CAISSON TYPE HOLLOW FLOOR SLABS OF MONOLITHIC MULTI-STOREYED BUILDINGS

    OpenAIRE

    Malakhova Anna Nikolaevna

    2016-01-01

    One of the disadvantages of building structures made of reinforced concrete is their considerable weight. One of the trends to decrease the weight of concrete structures, including floor slabs, is the arrangement of voids in the cross-sectional building structures. In Russian and foreign practice paper, cardboard and plastic tubes has been used for creation of voids in the construction of monolithic floor slabs. Lightweight concretes were also used for production of precast hollow core floor ...

  14. Rollout of quality assurance interventions in labor room in two districts of Bihar, India

    OpenAIRE

    Jyoti Sharma; Sutapa B Neogi; Preeti Negandhi; Monika Chauhan; Siddharth Reddy; Ghanshyam Sethy

    2016-01-01

    Background: Quality of care at the facilities during childbirth remains a major concern. Improved quality could have the greatest dividend in saving maternal and newborn lives. Objective: The objective of this study was to implement quality assurance measures in the labor rooms of select public health facilities in two districts of Bihar. Methods: The labor room quality assurance intervention was implemented in two districts, Gaya and Purnea in Bihar. Health facilities having >200 deliveries/...

  15. Error Floor Analysis of Coded Slotted ALOHA over Packet Erasure Channels

    DEFF Research Database (Denmark)

    Ivanov, Mikhail; Graell i Amat, Alexandre; Brannstrom, F.

    2014-01-01

    We present a framework for the analysis of the error floor of coded slotted ALOHA (CSA) for finite frame lengths over the packet erasure channel. The error floor is caused by stopping sets in the corresponding bipartite graph, whose enumeration is, in general, not a trivial problem. We therefore ...... identify the most dominant stopping sets for the distributions of practical interest. The derived analytical expressions allow us to accurately predict the error floor at low to moderate channel loads and characterize the unequal error protection inherent in CSA.......We present a framework for the analysis of the error floor of coded slotted ALOHA (CSA) for finite frame lengths over the packet erasure channel. The error floor is caused by stopping sets in the corresponding bipartite graph, whose enumeration is, in general, not a trivial problem. We therefore...

  16. Touch Is Everywhere: Floor Surfaces as Ambient Haptic Interfaces.

    Science.gov (United States)

    Visell, Y; Law, A; Cooperstock, J R

    2009-01-01

    Floor surfaces are notable for the diverse roles that they play in our negotiation of everyday environments. Haptic communication via floor surfaces could enhance or enable many computer-supported activities that involve movement on foot. In this paper, we discuss potential applications of such interfaces in everyday environments and present a haptically augmented floor component through which several interaction methods are being evaluated. We describe two approaches to the design of structured vibrotactile signals for this device. The first is centered on a musical phrase metaphor, as employed in prior work on tactile display. The second is based upon the synthesis of rhythmic patterns of virtual physical impact transients. We report on an experiment in which participants were able to identify communication units that were constructed from these signals and displayed via a floor interface at well above chance levels. The results support the feasibility of tactile information display via such interfaces and provide further indications as to how to effectively design vibrotactile signals for them.

  17. Construction and engineering report for advanced nuclear fuel development facility

    International Nuclear Information System (INIS)

    Cho, S. W.; Park, J. S.; Kwon, S.J.; Lee, K. W.; Kim, I. J.; Yu, C. H.

    2003-09-01

    The design and construction of the fuel technology development facility was aimed to accommodate general nuclear fuel research and development for the HANARO fuel fabrication and advanced fuel researches. 1. Building size and room function 1) Building total area : approx. 3,618m 2 , basement 1st floor, ground 3th floor 2) Room function : basement floor(machine room, electrical room, radioactive waste tank room), 1st floor(research reactor fuel fabrication facility, pyroprocess lab., metal fuel lab., nondestructive lab., pellet processing lab., access control room, sintering lab., etc), 2nd floor(thermal properties measurement lab., pellet characterization lab., powder analysis lab., microstructure analysis lab., etc), 3rd floor(AHU and ACU Room) 2. Special facility equipment 1) Environmental pollution protection equipment : ACU(2sets), 2) Emergency operating system : diesel generator(1set), 3) Nuclear material handle, storage and transport system : overhead crane(3sets), monorail hoist(1set), jib crane(2sets), tank(1set) 4) Air conditioning unit facility : AHU(3sets), packaged air conditioning unit(5sets), 5) Automatic control system and fire protection system : central control equipment(1set), lon device(1set), fire hose cabinet(3sets), fire pump(3sets) etc

  18. Robust Floor Determination Algorithm for Indoor Wireless Localization Systems under Reference Node Failure

    Directory of Open Access Journals (Sweden)

    Kriangkrai Maneerat

    2016-01-01

    Full Text Available One of the challenging problems for indoor wireless multifloor positioning systems is the presence of reference node (RN failures, which cause the values of received signal strength (RSS to be missed during the online positioning phase of the location fingerprinting technique. This leads to performance degradation in terms of floor accuracy, which in turn affects other localization procedures. This paper presents a robust floor determination algorithm called Robust Mean of Sum-RSS (RMoS, which can accurately determine the floor on which mobile objects are located and can work under either the fault-free scenario or the RN-failure scenarios. The proposed fault tolerance floor algorithm is based on the mean of the summation of the strongest RSSs obtained from the IEEE 802.15.4 Wireless Sensor Networks (WSNs during the online phase. The performance of the proposed algorithm is compared with those of different floor determination algorithms in literature. The experimental results show that the proposed robust floor determination algorithm outperformed the other floor algorithms and can achieve the highest percentage of floor determination accuracy in all scenarios tested. Specifically, the proposed algorithm can achieve greater than 95% correct floor determination under the scenario in which 40% of RNs failed.

  19. Sea-floor geology in northwestern Block Island Sound, Rhode Island

    Science.gov (United States)

    McMullen, Katherine Y.; Poppe, Lawrence J.; Ackerman, Seth D.; Blackwood, Dann S.; Woods, D.A.

    2014-01-01

    Multibeam-echosounder and sidescan-sonar data, collected by the National Oceanic and Atmospheric Administration in a 69-square-kilometer area of northwestern Block Island Sound, are used with sediment samples, and still and video photography of the sea floor, collected by the U.S. Geological Survey at 43 stations within this area, to interpret the sea-floor features and sedimentary environments. Features on the sea floor include boulders, sand waves, scour depressions, modern marine sediments, and trawl marks. Boulders, which are often several meters wide, are found in patches in the shallower depths and tend to be overgrown with sessile flora and fauna. They are lag deposits of winnowed glacial drift, and reflect high-energy environments characterized by processes associated with erosion and nondeposition. Sand waves and megaripples tend to have crests that either trend parallel to shore with 20- to 50-meter (m) wavelengths or trend perpendicular to shore with several-hundred-meter wavelengths. The sand waves reflect sediment transport directions perpendicular to shore by waves, and parallel to shore by tidal or wind-driven currents, respectively. Scour depressions, which are about 0.5 m lower than the surrounding sea floor, have floors of gravel and coarser sand than bounding modern marine sediments. These scour depressions, which are conspicuous in the sidescan-sonar data because of their more highly reflective coarser sediment floors, are likely formed by storm-generated, seaward-flowing currents and maintained by the turbulence in bottom currents caused by their coarse sediments. Areas of the sea floor with modern marine sediments tend to be relatively flat to current-rippled and sandy.

  20. 17 CFR 155.2 - Trading standards for floor brokers.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Trading standards for floor brokers. 155.2 Section 155.2 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION TRADING STANDARDS § 155.2 Trading standards for floor brokers. Each contract market shall adopt and submit...

  1. Room 209 excavation response test in the underground research laboratory

    International Nuclear Information System (INIS)

    Lang, P.A.

    1989-01-01

    An in situ excavation response test was conducted at the Canadian Underground Research Laboratory (URL) in conjunction with excavation of a tunnel (Room 209) through a near-vertical water-bearing fracture oriented perpendicular to the tunnel axis. Encountering a fracture with such desirable characteristics provided a unique opportunity during construction of the URL to try out instrumentation and analytical methods for use in the Excavation Response Experiment (ERE) planned as one of the major URL experiments. The test has produced a valuable data set for validating numerical models. Four modelling groups predicted the response that would be monitored by the instruments. The predictions of the mechanical response were generally good. However, the predictions of the permeability and hydraulic pressure changes in the fracture, and the water flows into the tunnel, were poor. It is concluded that we may not understand the mechanisms that occur in the fracture in response to excavation. Laboratory testing, and development of a contracting joint code, has been initiated to further investigate this phenomenon. Preliminary results indicate that the excavation damaged zone in the walls and crown is less than 0.5 m thick and has relatively low permeability. The damaged zone in the floor is at least 1 m thick and has relatively high permeability. The damage in the floor could be reduced in future excavations by using controlled blasting methods similar to those used for the walls and crown

  2. Characterization of the protective capacity of flooring systems using force-deflection profiling.

    Science.gov (United States)

    Glinka, Michal N; Karakolis, Thomas; Callaghan, Jack P; Laing, Andrew C

    2013-01-01

    'Safety floors' aim to decrease the risk of fall-related injuries by absorbing impact energy during falls. Ironically, excessive floor deflection during walking or standing may increase fall risk. In this study we used a materials testing system to characterize the ability of a range of floors to absorb energy during simulated head and hip impacts while resisting deflection during simulated single-leg stance. We found that energy absorption for all safety floors (mean (SD)=14.8 (4.9)J) and bedside mats (25.1 (9.3)J) was 3.2- to 5.4-fold greater than the control condition (commercial carpet). While footfall deflections were not significantly different between safety floors (1.8 (0.7)mm) and the control carpet (3.7 (0.6)mm), they were significantly higher for two bedside mats. Finally, all of the safety floors, and two bedside mats, displayed 3-10 times the energy-absorption-to-deflection ratios observed for the baseline carpet. Overall, these results suggest that the safety floors we tested effectively addressed two competing demands required to reduce fall-related injury risk; namely the ability to absorb substantial impact energy without increasing footfall deflections. This study contributes to the literature suggesting that safety floors are a promising intervention for reducing fall-related injury risk in older adults. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Floor response spectra of buildings with uncertain structural properties

    International Nuclear Information System (INIS)

    Chen, P.C.

    1975-01-01

    All Category I equipment, such as reactors, vessels, and major piping systems of nuclear power plants, is required to withstand earthquake loadings in order to minimize risk of seismic damage. The equipment is designed by using response spectra of the floor on which the equipment is mounted. The floor response spectra are constructed usually from the floor response time histories which are obtained through a deterministic dynamic analysis. This analysis assumes that all structural parameters, such as mass, stiffness, and damping have been calculated precisely, and that the earthquakes are known. However, structural parameters are usually difficult to determine precisely if the structures are massive and/or irregular, such as nuclear containments and its internal structures with foundation soil incorporated into the analysis. Faced with these uncertainties, it has been the practice to broaden the floor response spectra peaks by +-10 percent of the peak frequencies on the basis of conservatism. This approach is based on engineering judgement and does not have an analytical basis to provide a sufficient level of confidence in using these spectra for equipment design. To insure reliable design, it is necessary to know structural response variations due to variations in structural properties. This consideration leads to the treatment of structural properties as random variables and the use of probabilistic methods to predict structural response more accurately. New results on floor response spectra of buildings with uncertain structural properties obtained by determining the probabilistic dynamic response from the deterministic dynamic response and its standard deviation are presented. The resulting probabilistic floor response spectra are compared with those obtained deterministically, and are shown to provide a more reliable method for determining seismic forces

  4. Room Acoustics

    Science.gov (United States)

    Kuttruff, Heinrich; Mommertz, Eckard

    The traditional task of room acoustics is to create or formulate conditions which ensure the best possible propagation of sound in a room from a sound source to a listener. Thus, objects of room acoustics are in particular assembly halls of all kinds, such as auditoria and lecture halls, conference rooms, theaters, concert halls or churches. Already at this point, it has to be pointed out that these conditions essentially depend on the question if speech or music should be transmitted; in the first case, the criterion for transmission quality is good speech intelligibility, in the other case, however, the success of room-acoustical efforts depends on other factors that cannot be quantified that easily, not least it also depends on the hearing habits of the listeners. In any case, absolutely "good acoustics" of a room do not exist.

  5. Development of a 3-dimensional seismic isolation floor for computer systems

    International Nuclear Information System (INIS)

    Kurihara, M.; Shigeta, M.; Nino, T.; Matsuki, T.

    1991-01-01

    In this paper, we investigated the applicability of a seismic isolation floor as a method for protecting computer systems from strong earthquakes, such as computer systems in nuclear power plants. Assuming that the computer system is guaranteed for 250 cm/s 2 of input acceleration in the horizontal and vertical directions as the seismic performance, the basic design specification of the seismic isolation floor is considered as follows. Against S 1 level earthquakes, the maximum acceleration response of the seismic isolation floor in the horizontal and vertical directions is kept less than 250 cm/s 2 to maintain continuous computer operation. Against S 2 level earthquakes, the isolation floor allows large horizontal movement and large displacement of the isolation devices to reduce the acceleration response, although it is not guaranteed to be less than 250 cm/s 2 . By reducing the acceleration response, however, serious damage to the computer systems is reduced, so that they can be restarted after an earthquake. Usually, seismic isolation floor systems permit 2-dimensional (horizontal) isolation. However, in the case of just-under-seated earthquakes, which have large vertical components, the vertical acceleration response of this system is amplified by the lateral vibration of the frame of the isolation floor. Therefore, in this study a 3-dimensional seismic isolation floor, including vertical isolation, was developed. This paper describes 1) the experimental results of the response characteristics of the 3-dimensional seismic isolation floor built as a trial using a 3-dimensional shaking table, and 2) comparison of a 2-dimensional analytical model, for motion in one horizontal direction and the vertical direction, to experimental results. (J.P.N.)

  6. Sea-floor morphology and sedimentary environments in southern Narragansett Bay, Rhode Island

    Science.gov (United States)

    McMullen, Katherine Y.; Poppe, Lawrence J.; Blackwood, Dann S.; Nardi, Matthew J.; Andring, Matthew A.

    2015-09-09

    Multibeam echosounder data collected by the National Oceanic and Atmospheric Administration along with sediment samples and still and video photography of the sea floor collected by the U.S. Geological Survey were used to interpret sea-floor features and sedimentary environments in southern Narragansett Bay, Rhode Island, as part of a long-term effort to map the sea floor along the northeastern coast of the United States. Sea-floor features include rocky areas and scour depressions in high-energy environments characterized by erosion or nondeposition, and sand waves and megaripples in environments characterized by coarse-grained bedload transport. Two shipwrecks are also located in the study area. Much of the sea floor is relatively featureless within the resolution of the multibeam data; sedimentary environments in these areas are characterized by processes associated with sorting and reworking. This report releases bathymetric data from the multibeam echosounder, grain-size analyses of sediment samples, and photographs of the sea floor and interpretations of the sea-floor features and sedimentary environments. It provides base maps that can be used for resource management and studies of topics such as benthic ecology, contaminant inventories, and sediment transport.

  7. Pyroclastic Deposits in the Floor-fractured Crater Alphonsus

    Science.gov (United States)

    Allen, Carlton C.; Donaldson-Hanna, Kerri L.; Pieters, Carle M.; Moriarty, Daniel P.; Greenhagen, Benjamin T.; Bennett, Kristen A.; Kramer, Georgiana Y.; Paige, David A.

    2013-01-01

    Alphonsus, the 118 km diameter floor-fractured crater, is located immediately east of Mare Nubium. Eleven pyroclastic deposits have been identified on the crater's floor. Early telescopic spectra suggest that the floor of Alphonsus is noritic, and that the pyroclastic deposits contain mixtures of floor material and a juvenile component including basaltic glass. Head and Wilson contend that Nubium lavas intruded the breccia zone beneath Alphonsus, forming dikes and fractures on the crater floor. In this model, the magma ascended to the level of the mare but cooled underground, and a portion broke thru to the surface in vulcanian (explosive) eruptions. Alternatively, the erupted material could be from a source unrelated to the mare, in the style of regional pyroclastic deposits. High-resolution images and spectroscopy from the Moon Mineralogy Mapper (M3), Diviner Lunar Radiometer, and Lunar Reconnaissance Orbiter Camera Narrow Angle Camera (NAC) provide data to test these formation models. Spectra from M3 confirm that the crater floor is primarily composed of noritic material, and that the Nubium lavas are basaltic. Spectra from the three largest pyroclastic deposits in Alphonsus are consistent with a minor low- Ca pyroxene component in a glass-rich matrix. The centers of the 2 micron absorption bands have wavelengths too short to be of the same origin as the Nubium basalts. Diviner Christiansen feature (CF) values were used to estimate FeO abundances for the crater floor, Nubium soil, and pyroclastic deposits. The estimated abundance for the crater floor (7.5 +/- 1.4 wt.%) is within the range of FeO values for Apollo norite samples. However, the estimated FeO abundance for Nubium soil (13.4 +/- 1.4 wt.%) is lower than those measured in most mare samples. The difference may reflect contamination of the mare soil by highland ejecta. The Diviner-derived FeO abundance for the western pyroclastic deposit is 13.8 +/- 3.3 wt.%. This is lower than the values for mare soil

  8. Older Women in Single Room Occupant (SRO) Hotels: A Seattle Profile.

    Science.gov (United States)

    Lally, Maureen; And Others

    1979-01-01

    Life histories and daily routines of women over the age of 55 living in Seattle single room occupant (SRO) hotels were studied using observational and interviewing methods. Residence in SRO's appears to be part of a natural life history progression for these women rather than a result of social pathology. (Author)

  9. Vivienda residencial, México

    Directory of Open Access Journals (Sweden)

    Artigas, Francisco

    1966-10-01

    Full Text Available This building has two levels, and has the following internal distribution. Ground floor: garage, cellar, service quarters, ironing room, etc. Top floor: living room, dining room, main bedroom, a bedroom with two beds, kitchen, study, etc. Vegetation plays an important role in the aesthetic composition of the external design, as a highly integrated element in the general pattern. The materials employed by the architect are of very fine quality and beauty, and have been chosen with ability and sincerity of purpose.Este edificio, que está desarrollado en dos niveles, presenta la siguiente distribución: En la planta baja: el garaje, bodega, habitaciones del servicio, cuarto de plancha, etc. En la planta superior: la sala de estar, comedor, dormitorio principal, un dormitorio de dos camas, cocina, estudio, etc. En la composición estética de las fachadas juega un papel importante la vegetación, como elemento plenamente integrado en el conjunto. Los materiales empleados, nobles y de gran belleza, lo han sido con acierto y sinceridad notable.

  10. Virtual environment display for a 3D audio room simulation

    Science.gov (United States)

    Chapin, William L.; Foster, Scott

    1992-06-01

    Recent developments in virtual 3D audio and synthetic aural environments have produced a complex acoustical room simulation. The acoustical simulation models a room with walls, ceiling, and floor of selected sound reflecting/absorbing characteristics and unlimited independent localizable sound sources. This non-visual acoustic simulation, implemented with 4 audio ConvolvotronsTM by Crystal River Engineering and coupled to the listener with a Poihemus IsotrakTM, tracking the listener's head position and orientation, and stereo headphones returning binaural sound, is quite compelling to most listeners with eyes closed. This immersive effect should be reinforced when properly integrated into a full, multi-sensory virtual environment presentation. This paper discusses the design of an interactive, visual virtual environment, complementing the acoustic model and specified to: 1) allow the listener to freely move about the space, a room of manipulable size, shape, and audio character, while interactively relocating the sound sources; 2) reinforce the listener's feeling of telepresence into the acoustical environment with visual and proprioceptive sensations; 3) enhance the audio with the graphic and interactive components, rather than overwhelm or reduce it; and 4) serve as a research testbed and technology transfer demonstration. The hardware/software design of two demonstration systems, one installed and one portable, are discussed through the development of four iterative configurations. The installed system implements a head-coupled, wide-angle, stereo-optic tracker/viewer and multi-computer simulation control. The portable demonstration system implements a head-mounted wide-angle, stereo-optic display, separate head and pointer electro-magnetic position trackers, a heterogeneous parallel graphics processing system, and object oriented C++ program code.

  11. Effect of different flooring systems on claw conformation of dairy cows.

    Science.gov (United States)

    Telezhenko, E; Bergsten, C; Magnusson, M; Nilsson, C

    2009-06-01

    The effect of different flooring surfaces in walking and standing areas on claw conformation, claw horn growth, and wear was studied in 2 experiments during 2 consecutive housing seasons in a research dairy herd of 170 cows. In experiment 1, the flooring systems tested were solid rubber mats, mastic asphalt with and without rubber-matted feed-stalls, and aged concrete slats. In experiment 2, slatted concrete flooring was compared with slatted rubber flooring. The cows were introduced to the respective flooring systems in early lactation and their claws were trimmed before the exposure period. Toe length, toe angle, sole concavity, and claw width, as well as claw growth and wear rates were recorded for lateral and medial claws of the left hind limb. Claw asymmetry calculations were based on these claw measurements and on differences in sole protrusion between lateral and medial soles. Asphalt floors caused shorter toe length and steeper toe angle. They also increased wear on rear claws (5.30 +/- 0.31 and 5.95 +/- 0.33 mm/mo for lateral and medial claw, respectively; LSM +/- SE) and horn growth rate (5.12 +/- 0.36 and 5.83 +/- 0.31 mm/mo of lateral and medial claws, respectively). Rubber mats instead of asphalt in walking areas reduced wear (1.36 +/- 0.19 and 2.02 +/- 0.20 mm/mo for lateral and medial claw, respectively) and claw growth (3.83 +/- 0.23 and 3.94 +/- 0.17 mm/mo for lateral and medial claw, respectively). Rubber-matted feed-stalls together with asphalt walkways decreased claw wear (3.29 +/- 0.31 and 4.10 +/- 0.32 mm/mo for lateral and medial claw, respectively). The concavity of claw soles was reduced on asphalt, especially in the lateral rear claws. Rubber matting in feed-stalls prevented loss of sole concavity compared with asphalt. Claw asymmetry did not differ between flooring systems. While different access to abrasive flooring affected claw conformation, there was no evidence that flooring system influenced the disproportion between lateral and

  12. Simulation of a model predictive room temperature control by use of an ideal weather forecast; Simulation einer praediktiven Raumtemperaturregelung unter Verwendung einer idealen Wettervorhersage

    Energy Technology Data Exchange (ETDEWEB)

    Goertler, Gregor [Fachhochschulstudiengaenge Burgenland GesmbH, Pinkafeld (Austria). Kernkompetenzbereich Energie- und Umweltmanagement; Beigelboeck, Barbara

    2010-12-15

    Due to the use of MPC (Model Predictive Control) for room heating applications users and constructors expect nameable energy savings. By usage of a simulation for a special case the energy saving potential of predictive control algorithm for room temperature control in connection with an ideal weather forecast, in comparison to established algorithms (PI-control, two level controller) is estimated. The controlled system with the control variable room temperature is a room with floor heating which was modelled in TRNSYS. A linear state space model of the controlled system was derived with suitable identification methods. This model was used by the predictive control algorithm, which was programmed in MATLAB. The weather data was taken from the TRNSYS library and has been made available also for the control algorithm, so that an ideal weather forecast was established. For the example considered in this paper, the amount of energy saving was 10 % per year with the MPC-controller compared to a PI-controller. (Copyright copyright 2010 Ernst and Sohn Verlag fuer Architektur und technische Wissenschaften GmbH and Co. KG, Berlin)

  13. Laser sheet light flow visualization for evaluating room air flowsfrom Registers

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Claret, Valerie; Smith, Brian

    2006-04-01

    Forced air heating and cooling systems and whole house ventilation systems deliver air to individual rooms in a house via supply registers located on walls ceilings or floors; and occasionally less straightforward locations like toe-kicks below cabinets. Ideally, the air velocity out of the registers combined with the turbulence of the flow, vectoring of air by register vanes and geometry of register placement combine to mix the supply air within the room. A particular issue that has been raised recently is the performance of multiple capacity and air flow HVAC systems. These systems vary the air flow rate through the distribution system depending on the system load, or if operating in a ventilation rather than a space conditioning mode. These systems have been developed to maximize equipment efficiency, however, the high efficiency ratings do not include any room mixing effects. At lower air flow rates, there is the possibility that room air will be poorly mixed, leading to thermal stratification and reduced comfort for occupants. This can lead to increased energy use as the occupants adjust the thermostat settings to compensate and parts of the conditioned space have higher envelope temperature differences than for the well mixed case. In addition, lack of comfort can be a barrier to market acceptance of these higher efficiency systems To investigate the effect on room mixing of reduced air flow rates requires the measurement of mixing of supply air with room air throughout the space to be conditioned. This is a particularly difficult exercise if we want to determine the transient performance of the space conditioning system. Full scale experiments can be done in special test chambers, but the spatial resolution required to fully examine the mixing problem is usually limited by the sheer number of thermal sensors required. Current full-scale laboratory testing is therefore severely limited in its resolution. As an alternative, we used a water-filled scale model

  14. Fast mean and variance computation of the diffuse sound transmission through finite-sized thick and layered wall and floor systems

    Science.gov (United States)

    Decraene, Carolina; Dijckmans, Arne; Reynders, Edwin P. B.

    2018-05-01

    A method is developed for computing the mean and variance of the diffuse field sound transmission loss of finite-sized layered wall and floor systems that consist of solid, fluid and/or poroelastic layers. This is achieved by coupling a transfer matrix model of the wall or floor to statistical energy analysis subsystem models of the adjacent room volumes. The modal behavior of the wall is approximately accounted for by projecting the wall displacement onto a set of sinusoidal lateral basis functions. This hybrid modal transfer matrix-statistical energy analysis method is validated on multiple wall systems: a thin steel plate, a polymethyl methacrylate panel, a thick brick wall, a sandwich panel, a double-leaf wall with poro-elastic material in the cavity, and a double glazing. The predictions are compared with experimental data and with results obtained using alternative prediction methods such as the transfer matrix method with spatial windowing, the hybrid wave based-transfer matrix method, and the hybrid finite element-statistical energy analysis method. These comparisons confirm the prediction accuracy of the proposed method and the computational efficiency against the conventional hybrid finite element-statistical energy analysis method.

  15. Mitigation of houses with extremely high indoor radon concentrations

    International Nuclear Information System (INIS)

    Jiranek, M.; Neznal, M.

    2006-01-01

    Full text of publication follows: The paper reports on the experience of the Czech Technical University in dealing with mitigation of houses in which unusually high indoor radon concentrations were found. The whole process of remediation is illustrated by example of an old single-family house that was built in the area formed by highly permeable soils with high radon content in the soil air. T he house has a small cellar located under 1/5 of the ground floor area. Two types of floors, i.e. timber floors and cracked concrete slabs were found in the house. As a result of extremely high radon concentration in the sub-floor region (up to 600 kBq/m 3 ) and leaky structures in contact with soil, radon concentrations around 100 kBq/m 3 in the cellar and up to 60 kBq/m 3 in the living rooms on the ground floor were measured prior to mitigation. Mitigation measures that were carried out in the house consist of reconstruction of timber floors and installation of active soil depressurization. Timber floors were replaced with concrete slab fitted with damp proof membrane, thermal insulation and floor covering. The soil depressurization system was made up of two sections. The first section is composed of the network of perforated pipes inserted in the drainage layer placed under the new floors and four perforated tubes drilled under the existing floors. The soil air from this section is extracted by means of a roof fan installed at the top of the vertical exhaust pipe running inside the living space and terminating above the roof. The second section was designed to withdraw by means of a small fan radon-laden air from the filling in the floor above the cellar and from perforated tubes drilled into the sub-floor region under the rooms adjacent to the cellar. It serves also for the active ventilation of the cellar. Pressure, temperature and radon concentration sensors were installed into the drainage layer during the reconstruction of floors to record variations in these

  16. Regular exercisers have stronger pelvic floor muscles than nonregular exercisers at midpregnancy.

    Science.gov (United States)

    Bø, Kari; Ellstrøm Engh, Marie; Hilde, Gunvor

    2018-04-01

    Today all healthy pregnant women are encouraged to be physically active throughout pregnancy, with recommendations to participate in at least 30 minutes of aerobic activity on most days of the week in addition to performing strength training of the major muscle groups 2-3 days per week and also pelvic floor muscle training. There is, however, an ongoing debate whether general physical activity enhances or declines pelvic floor muscle function. The objectives of the study were to compare vaginal resting pressure, pelvic floor muscle strength, and endurance in regular exercisers (exercise ≥30 minutes 3 or more times per week) and nonexercisers at midpregnancy. Furthermore, another objective was to assess whether regular general exercise or pelvic floor muscle strength was associated with urinary incontinence. This was a cross-sectional study at mean gestational week 20.9 (±1.4) including 218 nulliparous pregnant women, with a mean age of 28.6 years (range, 19-40 years) and prepregnancy body mass index of 23.9 kg/m 2 (SD, 4.0). Vaginal resting pressure, pelvic floor muscle strength, and pelvic floor muscle endurance were measured by a high-precision pressure transducer connected to a vaginal balloon. The International Consultation on Incontinence Questionnaire Urinary Incontinence Short Form was used to assess urinary incontinence. Differences between groups were analyzed using an independent-sample Student t test. Linear regression analysis was conducted to adjust for prepregnancy body mass index, age, smoking during pregnancy, and regular pelvic floor muscle training during pregnancy. The significance value was set to P ≤ .05. Regular exercisers had statistically significant stronger (mean 6.4 cm H 2 O [95% confidence interval, 1.7-11.2]) and more enduring (mean 39.9 cm H 2 Osec [95% confidence interval, 42.2-75.7]) pelvic floor muscles. Only pelvic floor muscle strength remained statistically significant, when adjusting for possible confounders. Pelvic floor

  17. Clinical functional evaluation of female's pelvic floor: integrative review

    Directory of Open Access Journals (Sweden)

    Ana Carolina Nociti Lopes Fernandes

    2018-06-01

    Full Text Available Abstract Introduction: The effectiveness of pelvic floor muscle training (PFMT depends on the correct prescription of intensity, repetition and endurance of muscle contractions, which are provided by an adequate assessment of pelvic floor muscle. Objective: Verify the techniques, resources and strategies used for clinical functional evaluation of female pelvic floor (PF described in literature. Methods: It’s an integrative review of published studies and books from 2010 until December 2015. Relevant articles with complete description of PF evaluation were found through the use of Scielo, LILACS, PubMed and Medline databases. Results: 34 articles that fulfilled all the criteria were selected. Conclusion: The most used techniques, resources and strategies were: anamnesis, physical examination, measurement of pelvic floor muscle activity using Modified Oxford Scale or perineometry, and use of questionnaires to analyze patient's perspective of their own symptoms. Thus, we could use the parameters obtained in the evaluation to plan an ideal PFMT for each patient, so the physiotherapist would have a good database to analyze the evolution and define the end of therapy.

  18. Physical, Complementary, and Alternative Medicine in the Treatment of Pelvic Floor Disorders.

    Science.gov (United States)

    Arnouk, Alex; De, Elise; Rehfuss, Alexandra; Cappadocia, Carin; Dickson, Samantha; Lian, Fei

    2017-06-01

    The purpose of the study was to catalog the most recent available literature regarding the use of conservative measures in treatment of pelvic floor disorders. Pelvic floor disorders encompass abnormalities of urination, defecation, sexual function, pelvic organ prolapse, and chronic pain, and can have significant quality of life implications for patients. Current guidelines recommend behavioral modifications and conservative treatments as first-line therapy for pelvic floor disorders. We have reviewed the literature for articles published on physical, complementary, and alternative treatments for pelvic floor disorders over the past 5 years. Review of pelvic floor muscle physiotherapy (PFMT) and biofeedback (BF) shows a benefit for patients suffering from bladder dysfunction (incontinence, overactive bladder), bowel dysfunction (constipation, fecal incontinence), pelvic organ prolapse, and sexual dysfunction (pelvic pain). Combination of PFMT and BF has shown improved results compared to PFMT alone, and some studies find that electrical stimulation can augment the benefit of BF and PFMT. Additionally, acupuncture and cognitive behavioral therapy has shown to be an effective treatment for pelvic floor disorders, particularly with respect to pelvic pain. This update highlights beneficial conservative treatments available for pelvic floor dysfunction, and supplements the current literature on treatment options for patients suffering from these disorders.

  19. Floor-Fractured Craters on Ceres and Implications for Internal Composition and Processes

    Science.gov (United States)

    Buczkowski, D.; Schenk, P.; Scully, J. E. C.; Park, R. S.; Preusker, F.; Raymond, C. A.; Russell, C. T.

    2016-12-01

    Several of the impact craters on Ceres have patterns of fractures on their floors. These fractures appear similar to those found within a class of lunar craters referred to as Floor-Fractured Craters (FFCs) [1]. Lunar FFCs are characterized by anomalously shallow floors cut by radial, concentric, and/or polygonal fractures, and have been classified into crater classes, Types 1 through 6, based on their morphometric properties [1,2]. Models for their formation have included both floor uplift due to magmatic intrusion below the crater or floor shallowing due to viscous relaxation. However, the observation that the depth versus diameter (d/D) relationship of the FFCs is distinctly shallower than the same association for other lunar craters supports the hypotheses that the floor fractures form due to shallow magmatic intrusion under the crater [2]. We have cataloged the Ceres FFCs according to the classification scheme designed for the Moon. Large (>50 km) Ceres FFCs are most consistent with Type 1 lunar FFCs, having deep floors, central peaks, wall terraces, and radial and/or concentric fractures. Smaller craters on Ceres are more consistent with Type 4 lunar FFCs, having less-pronounced floor fractures and v-shaped moats separating the wall scarp from the crater interior. An analysis of the d/D ratio for Ceres craters shows that, like lunar FFCs, the Ceres FFCs are anomalously shallow. This suggests that the fractures on the floor of Ceres FFCs may be due the intrusion of a low-density material below the craters that is uplifting their floors. While on the Moon the intrusive material is hypothesized to be silicate magma, this is unlikely for Ceres. However, a cryovolcanic extrusive edifice has been identified on Ceres [3], suggesting that cryomagmatic intrusions could be responsible for the formation of the Ceres FFCs. References: [1] Schultz P. (1976) Moon, 15, 241-273 [2] Jozwiak L.M. et al (2015) JGR 117, doi: 10.1029/2012JE004134 [3] Ruesch O. et al (2016

  20. Assessment of pelvic floor dysfunctions using dynamic magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Hoda Salah Darwish

    2014-03-01

    Conclusion: Dynamic MRI is an ideal, non invasive technique which does not require patient preparation for evaluation of pelvic floor. It acts as one stop shop for diagnosing single or multiple pelvic compartment involvement in patients with pelvic floor dysfunction.

  1. Pelvic floor functional disorders in vaginally delivered primiparae

    OpenAIRE

    Antolic, Andrea

    2011-01-01

    In this study we examined pelvic floor functional disorders in primiparae with single pregnancies, cephalic presentation at term at the Charité delivery department before and during pregnancy as well as after vaginal delivery by means of questionnaire in relation to maternal, neonatal and obstetric risk factors. The pathophysiology of pelvic floor disorders is still not statisfyingly resolved. During pregnancy 74% of primiparae knew about the interrelation between delivery and sexual disorde...

  2. Chemical hazards analysis of resilient flooring for healthcare.

    Science.gov (United States)

    Lent, Tom; Silas, Julie; Vallette, Jim

    2010-01-01

    This article addresses resilient flooring, evaluating the potential health effects of vinyl flooring and the leading alternatives-synthetic rubber, polyolefin, and linoleum-currently used in the healthcare marketplace. The study inventories chemicals incorporated as components of each of the four material types or involved in their life cycle as feedstocks, intermediary chemicals, or emissions. It then characterizes those chemicals using a chemical hazard-based framework that addresses persistence and bioaccumulation, human toxicity, and human exposures.

  3. Quality of life in women with pelvic floor dysfunction

    Directory of Open Access Journals (Sweden)

    Mladenović-Segedi Ljiljana

    2011-01-01

    Full Text Available Background/Aim. Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfaction in adult women with pelvic organ prolapse presenting to tertiary care clinic for surgical treatment. Methods. This prospective case-control study included 50 patients who presented to tertiary care gynecology clinic for surgical treatment and 50 controls with normal pelvic floor support and without urinary incontinence who presented tertiary care gynecology clinic for other reasons. Both, patients and controls, completed two quastionnaires recommended for the evaluation of symptoms (Pelvic floor distress inventory - short forms and quality of life impact (Pelvic floor impact questionnaire - short form of pelvic organ prolapse, and Body Image Scale. Results. The patients scored significantly worse on the prolapse, urinary, colorectal scales and overall score of Pelvic floor distress inventory - 20 than controls subjects (134.91 vs 78.08; p < 0.01. The patients also measured significant decrease in condition- specific quality of life (89.23 vs 3.1; p < 0.01. They were more likely to feel self-conscious (78% vs 42%; p < 0.01, less likely to feel physically attractive (78% vs 22%; p < 0.01, more likely to have difficulty looking at themselves naked (70% vs 42%; p < 0.01, less likely to feel sexually attractive (64% vs 32%; p < 0.01, and less likely to feel feminine (56% vs 16%; p < 0.05, than controls. There were no differencies in their feeling of dissatisfaction with appearance when dressed, avoiding people because of appereance and overall dissatisfaction with

  4. Modelling the cost-effectiveness of impact-absorbing flooring in Swedish residential care facilities.

    Science.gov (United States)

    Ryen, Linda; Svensson, Mikael

    2016-06-01

    Fall-related injuries among the elderly, specifically hip fractures, cause significant morbidity and mortality as well as imposing a substantial financial cost on the health care system. Impact-absorbing flooring has been advocated as an effective method for preventing hip fractures resulting from falls. This study identifies the cost-effectiveness of impact-absorbing flooring compared to standard flooring in residential care facilities for the elderly in a Swedish setting. An incremental cost-effectiveness analysis was performed comparing impact-absorbing flooring to standard flooring using a Markov decision model. A societal perspective was adopted and incremental costs were compared to incremental gains in quality-adjusted life years (QALYs). Data on costs, probability transitions and health-related quality of life measures were retrieved from the published literature and from Swedish register data. Probabilistic sensitivity analysis was performed through a Monte Carlo simulation. The base-case analysis indicates that the impact-absorbing flooring reduces costs and increases QALYs. When allowing for uncertainty we find that 60% of the simulations indicate that impact-absorbing flooring is cost-saving compared to standard flooring and an additional 20% that it has a cost per QALY below a commonly used threshold value : Using a modelling approach, we find that impact-absorbing flooring is a dominant strategy at the societal level considering that it can save resources and improve health in a vulnerable population. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  5. Impact of airflow interaction on inhaled air quality and transport of contaminants in rooms with personalized and total volume ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Cermak, Radim; Kovar, O.

    2003-01-01

    The impact of airflow interaction on inhaled air quality and transport of contaminants between occupants was studied in regard to pollution from floor covering, human bioeffluents and exhaled air, with combinations of two personalized ventilation systems (PV) with mixing and displacement...... quality with personalized and mixing ventilation was higher or at least similar compared to mixing ventilation alone. In the case of PV combined with displacement ventilation, the interaction caused mixing of the room air, an increase in the transport of bioeffluents and exhaled air between occupants and...... ventilation. In total, 80 L/s of clean air supplied at 20°C was distributed between the ventilation systems at different combinations of personalized airflow rate. Two breathing thermal manikins were used to simulate occupants in a full-scale test room. Regardless of the airflow interaction, the inhaled air...

  6. Reaction of calves to two flooring materials offered simultaneously in one pen.

    NARCIS (Netherlands)

    Stefanowska, J.; Swierstra, D.; Smits, A.C.; Berg, van den J.V.; Metz, J.H.M.

    2002-01-01

    Now that group housing is replacing individual crates, so that calves can lie, stand and walk on the pen floor, the quality of the floor for group-housed calves has become the focus of attention. The reaction of two groups of four calves to a double area of floor made from two materials (wooden

  7. Statistical analysis of the variation of floor vibrations in nuclear power plants subject to seismic loads

    International Nuclear Information System (INIS)

    Jussila, Vilho; Li, Yue; Fülöp, Ludovic

    2016-01-01

    Highlights: • Floor flexibility plays a non-negligible role in amplifying horizontal vibrations. • COV of in-floor horizontal and vertical acceleration are 0.15–0.25 and 0.25–0.55. • In-floor variation of vibrations is higher in lower floors. • Floor spectra from limited nodes underestimates vibrations by a factor of 1.5–1.75. - Abstract: Floor vibration of a reactor building subjected to seismic loads was investigated, with the aim of quantifying the variability of vibrations on each floor. A detailed 3D building model founded on the bedrock was excited simultaneously in three directions by artificial accelerograms compatible with Finnish ground response spectra. Dynamic simulation for 21 s was carried out using explicit time integration. The extracted results of the simulation were acceleration in several floor locations, transformed to pseudo-acceleration (PSA) spectra in the next stage. At first, the monitored locations on the floors were estimated by engineering judgement in order to arrive at a feasible number of floor nodes for post processing of the data. It became apparent that engineering judgment was insufficient to depict the key locations with high floor vibrations, which resulted in un-conservative vibration estimates. For this reason, a more systematic approach was later considered, in which nodes of the floors were selected with a more refined grid of 2 m. With this method, in addition to the highest PSA peaks in all directions, the full vibration distribution in each floor can be determined. A statistical evaluation of the floor responses was also carried out in order to define floor accelerations and PSAs with high confidence of non-exceedance. The conclusion was that in-floor variability can be as high as 50–60% and models with sufficiently dense node grids should be used in order to achieve a realistic estimate of floor vibration under seismic action. The effects of the shape of the input spectra, damping, and flexibility of the

  8. Statistical analysis of the variation of floor vibrations in nuclear power plants subject to seismic loads

    Energy Technology Data Exchange (ETDEWEB)

    Jussila, Vilho [VTT Technical Research Centre of Finland Ltd, Kemistintie 3, 02230 Espoo (Finland); Li, Yue [Dept. of Civil Engineering, Case Western Reserve University, Cleveland, OH 44106 (United States); Fülöp, Ludovic, E-mail: ludovic.fulop@vtt.fi [VTT Technical Research Centre of Finland Ltd, Kemistintie 3, 02230 Espoo (Finland)

    2016-12-01

    Highlights: • Floor flexibility plays a non-negligible role in amplifying horizontal vibrations. • COV of in-floor horizontal and vertical acceleration are 0.15–0.25 and 0.25–0.55. • In-floor variation of vibrations is higher in lower floors. • Floor spectra from limited nodes underestimates vibrations by a factor of 1.5–1.75. - Abstract: Floor vibration of a reactor building subjected to seismic loads was investigated, with the aim of quantifying the variability of vibrations on each floor. A detailed 3D building model founded on the bedrock was excited simultaneously in three directions by artificial accelerograms compatible with Finnish ground response spectra. Dynamic simulation for 21 s was carried out using explicit time integration. The extracted results of the simulation were acceleration in several floor locations, transformed to pseudo-acceleration (PSA) spectra in the next stage. At first, the monitored locations on the floors were estimated by engineering judgement in order to arrive at a feasible number of floor nodes for post processing of the data. It became apparent that engineering judgment was insufficient to depict the key locations with high floor vibrations, which resulted in un-conservative vibration estimates. For this reason, a more systematic approach was later considered, in which nodes of the floors were selected with a more refined grid of 2 m. With this method, in addition to the highest PSA peaks in all directions, the full vibration distribution in each floor can be determined. A statistical evaluation of the floor responses was also carried out in order to define floor accelerations and PSAs with high confidence of non-exceedance. The conclusion was that in-floor variability can be as high as 50–60% and models with sufficiently dense node grids should be used in order to achieve a realistic estimate of floor vibration under seismic action. The effects of the shape of the input spectra, damping, and flexibility of the

  9. Low-Impact Flooring: Does It Reduce Fall-Related Injuries?

    Science.gov (United States)

    Hanger, H Carl

    2017-07-01

    To compare fall rates and injuries from falls on low-impact flooring (LIF) compared with a standard vinyl flooring. Prospective, observational, nonrandomized controlled study. Subacute Older Persons Health ward (N = 20 beds). Older inpatients. Three different types of LIF. All falls in the ward were prospectively monitored using incident reporting, noting location and consequences of each fall. Fall rates (per 1000 bed days) and injuries, were compared between bedroom falls on LIF against those occurring on standard vinyl flooring (controls). Over 31 months, there were 278 bedroom falls (from 178 fallers). The bedroom fall rate (falls per 1000 bed days occupied) did not differ between the LIF and control groups (median 15 [IQR 8-18] versus 17 [IQR 9-23], respectively; P = .47). However, fall-related injuries were significantly less frequent when they occurred on LIFs (22% of falls versus 34% of falls on control flooring; P = .02). Fractures occurred in 0.7% of falls in the LIF cohort versus 2.3% in the control cohort. Rolling resistance when moving heavier equipment, such as beds or hoists, was an issue for staff on LIF. LIF significantly reduced fall-related injuries compared with a standard vinyl flooring, whereas they did not alter the overall risk of falling. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  10. Stochastic seismic floor response analysis method for various damping systems

    International Nuclear Information System (INIS)

    Kitada, Y.; Hattori, K.; Ogata, M.; Kanda, J.

    1991-01-01

    A study using the stochastic seismic response analysis method which is applicable for the estimation of floor response spectra is carried out. It is pointed out as a shortcoming in this stochastic seismic response analysis method, that the method tends to overestimate floor response spectra for low damping systems, e.g. 1% of the critical damping ratio. An investigation on the cause of the shortcoming is carried out and a number of improvements in this method were also made to the original method by taking correlation of successive peaks in a response time history into account. The application of the improved method to a typical BWR reactor building is carried out. The resultant floor response spectra are compared with those obtained by deterministic time history analysis. Floor response spectra estimated by the improved method consistently cover the response spectra obtained by the time history analysis for various damping ratios. (orig.)

  11. Hardwood? Carpet? or Tile? A comparison of flooring costs under residential conditions

    Science.gov (United States)

    David G. Martens; David G. Martens

    1971-01-01

    Initial installation cost, annual maintenance cost, and total long-term cost are important in the purchase of flooring products. Before deciding on a flooring material, the prudent buyer will consider each of these in relation to his personal desires. From these evaluations, he will then be able to select the flooring material that is best suited to his individual...

  12. Vision-based overlay of a virtual object into real scene for designing room interior

    Science.gov (United States)

    Harasaki, Shunsuke; Saito, Hideo

    2001-10-01

    In this paper, we introduce a geometric registration method for augmented reality (AR) and an application system, interior simulator, in which a virtual (CG) object can be overlaid into a real world space. Interior simulator is developed as an example of an AR application of the proposed method. Using interior simulator, users can visually simulate the location of virtual furniture and articles in the living room so that they can easily design the living room interior without placing real furniture and articles, by viewing from many different locations and orientations in real-time. In our system, two base images of a real world space are captured from two different views for defining a projective coordinate of object 3D space. Then each projective view of a virtual object in the base images are registered interactively. After such coordinate determination, an image sequence of a real world space is captured by hand-held camera with tracking non-metric measured feature points for overlaying a virtual object. Virtual objects can be overlaid onto the image sequence by taking each relationship between the images. With the proposed system, 3D position tracking device, such as magnetic trackers, are not required for the overlay of virtual objects. Experimental results demonstrate that 3D virtual furniture can be overlaid into an image sequence of the scene of a living room nearly at video rate (20 frames per second).

  13. Three-dimensional point-cloud room model in room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... and rotated around the vertical axis while for the second one the device is moved within the room. Benefits of both approaches were analyzed. The device's depth sensor provides a set of points in a three-dimensional coordinate system which represents scanned surfaces of the room interior. These data are used...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  14. Three-dimensional point-cloud room model for room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... and rotated around the vertical axis while for the second one the device is moved within the room. Benefits of both approaches were analyzed. The device's depth sensor provides a set of points in a three-dimensional coordinate system which represents scanned surfaces of the room interior. These data are used...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  15. Compilation of PRF Canyon Floor Pan Sample Analysis Results

    Energy Technology Data Exchange (ETDEWEB)

    Pool, Karl N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Minette, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wahl, Jon H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Greenwood, Lawrence R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Coffey, Deborah S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Scheele, Randall D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sinkov, Sergey I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Soderquist, Chuck Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brown, Garrett N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clark, Richard A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    On September 28, 2015, debris collected from the PRF (236-Z) canyon floor, Pan J, was observed to exhibit chemical reaction. The material had been transferred from the floor pan to a collection tray inside the canyon the previous Friday. Work in the canyon was stopped to allow Industrial Hygiene to perform monitoring of the material reaction. Canyon floor debris that had been sealed out was sequestered at the facility, a recovery plan was developed, and drum inspections were initiated to verify no additional reactions had occurred. On October 13, in-process drums containing other Pan J material were inspected and showed some indication of chemical reaction, limited to discoloration and degradation of inner plastic bags. All Pan J material was sealed back into the canyon and returned to collection trays. Based on the high airborne levels in the canyon during physical debris removal, ETGS (Encapsulation Technology Glycerin Solution) was used as a fogging/lock-down agent. On October 15, subject matter experts confirmed a reaction had occurred between nitrates (both Plutonium Nitrate and Aluminum Nitrate Nonahydrate (ANN) are present) in the Pan J material and the ETGS fixative used to lower airborne radioactivity levels during debris removal. Management stopped the use of fogging/lock-down agents containing glycerin on bulk materials, declared a Management Concern, and initiated the Potential Inadequacy in the Safety Analysis determination process. Additional drum inspections and laboratory analysis of both reacted and unreacted material are planned. This report compiles the results of many different sample analyses conducted by the Pacific Northwest National Laboratory on samples collected from the Plutonium Reclamation Facility (PRF) floor pans by the CH2MHill’s Plateau Remediation Company (CHPRC). Revision 1 added Appendix G that reports the results of the Gas Generation Rate and methodology. The scope of analyses requested by CHPRC includes the determination of

  16. Seismic isolation floor and vibration control equipment for nuclear power plant

    International Nuclear Information System (INIS)

    Niwa, H.; Fujimoto, S.; Aida, Y.; Miyano, H.

    1996-01-01

    We have developed a seismic isolation floor to improve protection against earthquakes for process computer systems, and a magnetic dynamic damper to reduce the mechanical vibrations of piping systems and pumps in nuclear power plants. Seismic excitation tests of the seismic isolation floor, on which process computer systems were installed, were performed using large earthquake simulators. The test results proved that the seismic isolation floor significantly reduced seismic forces. To control mechanical vibrations, a magnetic dynamic damper was designed using permanent magnets. This magnetic dynamic damper does not require mechanical springs, dampers and supports in the floors and walls of the building. Vibration tests using a rotating machine model confirmed that the magnetic dynamic damper effectively controlled vibrations in such a rotating machine model. (author)

  17. Modal analysis for floors in lightweight buildings

    DEFF Research Database (Denmark)

    Sjökvist, Lars-Göran; Brunskog, Jonas

    2007-01-01

    of acoustical prediction methods for those houses. The calculation standard EN 12354 is under evaluation since it cannot include most of the wooden houses that are built. It is important during such a work to have a great understanding of the acoustical behaviour for the wooden houses. The floors in lightweight...... constructions usually consist of plates that are stiffened by beams and by the dividing walls. In this study the wave equation for a plate is expanded by Fourier series and an analytical solution in terms of the eigenmodes of the entire system is presented. The studied system consists of one lightweigt floor...

  18. Acoustics advances study of sea floor hydrothermal flow

    Science.gov (United States)

    Rona, Peter A.; Jackson, Darrell R.; Bemis, Karen G.; Jones, Christopher D.; Mitsuzawa, Kyohiko; Palmer, David R.; Silver, Deborah

    Sub-sea floor hydrothermal convection systems discharge as plumes from point sources and as seepage from the ocean bottom. The plumes originate as clear, 150-400°C solutions that vent from mineralized chimneys; precipitate dissolved metals as particles to form black or white smokers as they turbulently mix with ambient seawater; and buoyantly rise hundreds of meters to a level of neutral density where they spread laterally. The seepage discharges from networks of fractures at the rock-water interface as clear, diffuse flow, with lower temperatures, metal contents, and buoyancy than the smokers. The diffuse flow may be entrained upward into plumes, or laterally by prevailing currents in discrete layers within tens of meters of the sea floor. The role of these flow regimes in dispersing heat, chemicals, and biological material into the ocean from sub-sea floor hydrothermal convection systems is being studied on a global scale.

  19. Effects of floor eggs on hatchability and later life performance in broiler chickens.

    Science.gov (United States)

    van den Brand, H; Sosef, M P; Lourens, A; van Harn, J

    2016-05-01

    Two experiments were conducted in which effects of floor eggs, washed floor eggs, and clean nest eggs were investigated on incubation characteristics and performance in later life of broiler chickens. In both experiments, a young and an older breeder flock were used in a 3×2 factorial design during incubation. In the second experiment, male and female chickens were reared separately until d 35 of age in floor pens. During this grow out trial, an extra group was created in which chickens obtained from clean nest eggs were mixed with chickens obtained from floor eggs, meaning that grow out period was set up as a 4×2×2 factorial design with 4 egg types, 2 breeder ages, and 2 sexes. In both experiments, fertility and hatchability of fertile eggs were lower in floor and washed eggs than in clean nest eggs (hatchability: experiment 1: 74.4 vs. 70.6 vs. 92.6% for floor eggs, washed floor eggs and clean nest eggs, respectively, P<0.001; experiment 2: 78.3 vs. 81.7 vs. 90.2%, respectively, P<0.001). In experiment 2, BW at d 0 of chickens obtained from clean nest eggs was higher than that of chickens from floor eggs and washed floor eggs (41.5 vs. 40.4 and 40.3 g, respectively; P<0.001). This difference disappeared during the grow out period and was absent at slaughter age at d 35 of age. Feed intake (FI), feed conversion ratio (FCR), and mortality during the grow out period were not affected by egg type. Incidence and severity of hock burns and footpad dermatitis were not affected by egg type or breeder age. Litter friability at d 35 of age tended to be lower in pens with chickens obtained from washed floor eggs compared to clean nest eggs. We conclude that incubation of floor eggs or washed floor eggs resulted in lower fertility and hatchability compared to clean nest eggs, but that performance during the grow out period was not affected. © 2016 Poultry Science Association Inc.

  20. [Perioperative nursing of internal sinus floor elevation surgery with piezosurgery].

    Science.gov (United States)

    He, Jing; Lei, Yiling; Wang, Liqiong

    2013-12-01

    This study aims to summarize the nursing experience in the internal sinus floor elevation surgery with piezosurgery. The medical records of 48 patients who underwent sinus floor elevation surgery with piezosurgery in the Department of Implantation, West China Hospital of Stomatology, Sichuan University, were reviewed. The preoperative, intraoperative, and postoperative nursing methods were summarized. All 48 patients underwent smooth surgeries and did not encounter complications. Careful preoperative preparation, careful and meticulous intraoperative nursing cooperation, and provision of sufficient health education after surgery to the patients are the key factors that ensure the success of internal sinus floor elevation surgery with piezosurgery.

  1. Bacterial Flux by Net Precipitation from the Phyllosphere to the Forest Floor.

    Science.gov (United States)

    Pound, P.; Van Stan, J. T., II; Moore, L. D.; Bittar, T.

    2016-12-01

    Transport pathways of microbes between ecosystem spheres (atmosphere, phyllosphere, and pedosphere) represent major fluxes in nutrient cycles and have the potential to significantly affect microbial ecological processes. We quantified a previously unexamined microbial flux from the phyllosphere to the pedosphere during rainfall and found it to be substantial. Net rainfall bacterial fluxes for throughfall and stemflow were quantified using flow cytometry and a quantitative Polymerase Chain Reaction (qPCR) assay for a Quercus virginiana (Mill., southern live oak) forest with heavy epiphyte cover of Tillandsia usneoides (L., Spanish moss) and Pleopeltis polypodiodes (L., resurrection fern) in coastal Georgia (Southeast USA). Total net precipitation flux of bacteria was 15 quadrillion cells year-1 ha-1, which (assuming a bacterial cell mass of 1 pg) is approximately 15 kg of bacterial biomass supply per year. Stemflow generation was low in this stand (rarely exceeded 10 L storm-1) yet still delivered half the annual net precipitation flux due to high bacterial concentration. The role of this previously unquantified bacterial flux in the forest floor has also been under studied, yet it may be significant by contributing functional community members (if living) or labile lysates (if dead).

  2. Pelvic Muscle Rehabilitation: A Standardized Protocol for Pelvic Floor Dysfunction

    Directory of Open Access Journals (Sweden)

    Rodrigo Pedraza

    2014-01-01

    Full Text Available Introduction. Pelvic floor dysfunction syndromes present with voiding, sexual, and anorectal disturbances, which may be associated with one another, resulting in complex presentation. Thus, an integrated diagnosis and management approach may be required. Pelvic muscle rehabilitation (PMR is a noninvasive modality involving cognitive reeducation, modification, and retraining of the pelvic floor and associated musculature. We describe our standardized PMR protocol for the management of pelvic floor dysfunction syndromes. Pelvic Muscle Rehabilitation Program. The diagnostic assessment includes electromyography and manometry analyzed in 4 phases: (1 initial baseline phase; (2 rapid contraction phase; (3 tonic contraction and endurance phase; and (4 late baseline phase. This evaluation is performed at the onset of every session. PMR management consists of 6 possible therapeutic modalities, employed depending on the diagnostic evaluation: (1 down-training; (2 accessory muscle isolation; (3 discrimination training; (4 muscle strengthening; (5 endurance training; and (6 electrical stimulation. Eight to ten sessions are performed at one-week intervals with integration of home exercises and lifestyle modifications. Conclusions. The PMR protocol offers a standardized approach to diagnose and manage pelvic floor dysfunction syndromes with potential advantages over traditional biofeedback, involving additional interventions and a continuous pelvic floor assessment with management modifications over the clinical course.

  3. A Comparison of Fishes and Invertebrates Living in the Vicinity of Energized and Unenergized Submarine Power Cables and Natural Sea Floor off Southern California, USA

    Directory of Open Access Journals (Sweden)

    Milton S. Love

    2017-01-01

    Full Text Available Increasing reliance on deep-water renewable energy has increased concerns about the effects of the electromagnetic fields (EMFs generated by submarine power cables on aquatic organisms. Off southern California, we conducted surveys of marine organisms living around energized and unenergized submarine power cables and nearby sea floor during 2012–2014 at depths between 76 and 213 m. In general, EMFs declined to background levels about one meter from the cable. We found no statistical difference in species composition between the fish assemblages along the energized and unenergized cables. The natural habitat community statistically differed from both energized and unenergized cable communities. Within species (or species groups, we found no differences in densities between energized and unenergized cables. Total fish densities were significantly higher around the cables than over the natural habitat. We found that invertebrate communities were structured by habitat type and depth and, similar to the fishes, there was no statistical difference between the energized and unenergized cables. Individually, the densities of four invertebrate species or species groups (Metridium farcimen, Luidia spp., unidentified black Crinoidea, and Urticina spp. differed between energized and unenergized cables, but this difference was not significant across all depth strata. The invertebrate community inhabiting the natural habitat strongly differed from the energized and unenergized cable community exhibiting the fewest species and individuals.

  4. Methods and Principles of Determining the Footwear and Floor Tribological Characteristics

    Directory of Open Access Journals (Sweden)

    D. Stamenković

    2017-09-01

    Full Text Available There are many standards relating to the anti-slip properties of footwear and flooring. These standards describe the different test methods and procedures for determining the footwear and floor slip resistance in different conditions. In this paper authors systematize the standards in this field applied in the EU and in Serbia and cite the Serbian institutes which are certified for this type of testing. In addition, the authors have carried out an analysis and comparison of the tests that are defined in these standards, indicating their advantages and disadvantages. Importance of the static and kinetic friction testing in determining the anti-slip properties of footwear and flooring is specifically indicated. Considering the current standards in area of slip resistance of the footwear and floor covering authors have determined the testing conditions for laboratory measuring the friction forces of different floor and footwear materials. The laboratory measurement has carried out at Faculty of Mechanical Engineering in Niš. The measuring results and their analysis are presented in the paper, as well.

  5. Energy analysis of under-floor air distribution (UFAD) system: An office building case study

    International Nuclear Information System (INIS)

    Alajmi, Ali F.; Abou-Ziyan, Hosny Z.; El-Amer, Wid

    2013-01-01

    Highlights: • The key issue for efficient performance of UFAD system is to ensure the thermal stratification establishment. • The unnecessarily excess air supplied to the room deteriorates the thermal stratification. • Improper UFAD operation increases the fan power and HVAC electric demand. • The proper UFAD system is typically more efficient than the existed UFAD system with energy savings of about 23–37%. • UFAD system shows over the CBAD system saving by about 37–39% during the peak months and 51% during October. - Abstract: This paper presents the results of an experimental and theoretical investigation to evaluate an under-floor air distribution (UFAD) system existed in an office building working on hot climate. Air temperature a distribution and supply air velocity are measured in two measuring stations; each consists of eight temperature sensors which were installed to measure room air temperatures along zone height. The obtained data shows an inefficient operation of the UFAD system which deteriorates the advantages of energy saving that presumed by UFAD system. The building energy simulation program, EnergyPlus, was used to identify the best setting of UFAD system and compare it with the existed UFAD and the conventional ceiling based air distribution (CBAD) system. The simulation results show that setting of room thermostat at 26 °C and supply air temperature at 18 °C provides the best efficient UFAD system. Due to improper operation of the tested UFAD system, its actual consumption is found to be higher than the best simulated UFAD by 23–37% during July to October. Also, the simulation results show that the HVAC demand of UFAD is lower than CBAD by 37–39% during July–September and 51% in October

  6. Rubber Flooring Impact on Production and Herdlife of Dairy Cows

    Science.gov (United States)

    Use of rubber flooring in dairies has become popular because of perceived cow comfort. The overall objective of this longitudinal study was to evaluate production, reproduction, and retention of first and second lactations of cows assigned to either rubber (RUB) or concrete (CON) flooring at the fe...

  7. CURB-BASED STREET FLOOR EXTRACTION FROM MOBILE TERRESTRIAL LIDAR POINT CLOUD

    Directory of Open Access Journals (Sweden)

    S. Ibrahim

    2012-07-01

    Full Text Available Mobile terrestrial laser scanners (MTLS produce huge 3D point clouds describing the terrestrial surface, from which objects like different street furniture can be generated. Extraction and modelling of the street curb and the street floor from MTLS point clouds is important for many applications such as right-of-way asset inventory, road maintenance and city planning. The proposed pipeline for the curb and street floor extraction consists of a sequence of five steps: organizing the 3D point cloud and nearest neighbour search; 3D density-based segmentation to segment the ground; morphological analysis to refine out the ground segment; derivative of Gaussian filtering to detect the curb; solving the travelling salesman problem to form a closed polygon of the curb and point-inpolygon test to extract the street floor. Two mobile laser scanning datasets of different scenes are tested with the proposed pipeline. The results of the extracted curb and street floor are evaluated based on a truth data. The obtained detection rates for the extracted street floor for the datasets are 95% and 96.53%. This study presents a novel approach to the detection and extraction of the road curb and the street floor from unorganized 3D point clouds captured by MTLS. It utilizes only the 3D coordinates of the point cloud.

  8. The Role of Pelvic Floor Muscles in Male Sexual Dysfunction and Pelvic Pain.

    Science.gov (United States)

    Cohen, Deborah; Gonzalez, Joshua; Goldstein, Irwin

    2016-01-01

    Sexual function is essential to good health and well-being in men. The relationship between male sexual function, pelvic floor function, and pelvic pain is complex and only beginning to be appreciated. The objectives of the current review are to examine these complex relationships, and to demonstrate how pelvic floor physical therapy can potentially improve the treatment of various male sexual dysfunctions, including erectile dysfunction and dysfunction of ejaculation and orgasm. Contemporary data on pelvic floor anatomy and function as they relate to the treatment of various male sexual dysfunctions were reviewed. Examination of evidence supporting the association between the male pelvic floor and erectile dysfunction, ejaculatory/orgasmic dysfunction, and chronic prostatitis/chronic pelvic pain syndrome, respectively. Evidence suggests a close relationship between the pelvic floor and male sexual dysfunction and a potential therapeutic benefit from pelvic floor therapy for men who suffer from these conditions. Pelvic floor physical therapy is a necessary tool in a more comprehensive bio-neuromusculoskeletal-psychosocial approach to the treatment of male sexual dysfunction and pelvic pain. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  9. Selection criteria and requirements for floors in nuclear facilities

    International Nuclear Information System (INIS)

    Kunze, S.

    1988-01-01

    As a surface protection of floors in nuclear facilities coatings, rubber and PVC coverings, respectively, are normally used, whereas stoneware tiles are still provided in rare cases only. All floor materials must be well decontaminable according to the German standard DIN 25415, Part 1. The general requirement is that low-porous, smooth products with little filler content, made of chemically resistant material, are very well decontaminable. Further investigations will be necessary for heavily loaded floor coatings. They include above all examinations for decontaminability after radiation and for wear and resistance to chemicals. These requirements have been compiled in DIN 55991. The examination of about 212 industrial products has revealed that the decontaminability of covering materials is frequently poor. Investigations have shown that the decontaminability is always deteriorated by additions of hygroscopic fillers. Additions of non-hygroscopic fillers and pigments may result in an excellent to poor decontaminability. The pore-free bonding of the covering materials by welding or jointing is of great importance with respect to the decontaminability of these floors. Care should be taken that the jointing compounds are as well decontaminable as the rubber coverings and stonewares. (orig.) [de

  10. Selection criteria and requirements for floors in nuclear plants

    International Nuclear Information System (INIS)

    Kunze, S.

    1987-01-01

    As a surface protection of floors in nuclear facilities coatings, rubber and PVC coverings, respectively, are normally used, whereas stoneware tiles are still provided in rare cases only. All floor materials must be well decontaminable according to the German standard DIN 25415, Part 1. The general requirement is that low-porous, smooth products with little filler content, made of chemically resistant material, are very well decontaminable. Further investigations will be necessary for heavily loaded floor coatings. They include above all examinations for decontaminability after radiation and for wear and resistance to chemicals. These requirements have been compiled in DIN 55991. The examination of about 200 industrial products has revealed that the decontaminability of covering materials is frequently poor. Investigations have shown that the decontaminability is always deteriorated by additions of hygroscopic fillers. Additions of non-hygroscopic fillers and pigments may result in an excellent to poor decontaminability. The pore-free bonding of the covering materials by welding or jointing is of great importance with respect to the decontaminability of these floors. Care should be taken that the jointing compounds are as well decontaminable as the rubber coverings and stonewares. (orig.) [de

  11. Virtual reality: new method of teaching anorectal and pelvic floor anatomy.

    Science.gov (United States)

    Dobson, Howard D; Pearl, Russell K; Orsay, Charles P; Rasmussen, Mary; Evenhouse, Ray; Ai, Zhuming; Blew, Gregory; Dech, Fred; Edison, Marcia I; Silverstein, Jonathan C; Abcarian, Herand

    2003-03-01

    A clear understanding of the intricate spatial relationships among the structures of the pelvic floor, rectum, and anal canal is essential for the treatment of numerous pathologic conditions. Virtual-reality technology allows improved visualization of three-dimensional structures over conventional media because it supports stereoscopic-vision, viewer-centered perspective, large angles of view, and interactivity. We describe a novel virtual reality-based model designed to teach anorectal and pelvic floor anatomy, pathology, and surgery. A static physical model depicting the pelvic floor and anorectum was created and digitized at 1-mm intervals in a CT scanner. Multiple software programs were used along with endoscopic images to generate a realistic interactive computer model, which was designed to be viewed on a networked, interactive, virtual-reality display (CAVE or ImmersaDesk). A standard examination of ten basic anorectal and pelvic floor anatomy questions was administered to third-year (n = 6) and fourth-year (n = 7) surgical residents. A workshop using the Virtual Pelvic Floor Model was then given, and the standard examination was readministered so that it was possible to evaluate the effectiveness of the Digital Pelvic Floor Model as an educational instrument. Training on the Virtual Pelvic Floor Model produced substantial improvements in the overall average test scores for the two groups, with an overall increase of 41 percent (P = 0.001) and 21 percent (P = 0.0007) for third-year and fourth-year residents, respectively. Resident evaluations after the workshop also confirmed the effectiveness of understanding pelvic anatomy using the Virtual Pelvic Floor Model. This model provides an innovative interactive educational framework that allows educators to overcome some of the barriers to teaching surgical and endoscopic principles based on understanding highly complex three-dimensional anatomy. Using this collaborative, shared virtual-reality environment

  12. Room with a View: Ethical Encounters in Room 13

    Science.gov (United States)

    Grube, Vicky

    2012-01-01

    In this article, the author describes ethical encounters in Room 13, a schoolroom where children made what they wanted, posed their own questions, and ran an art room like a small business. In Room 13 children had the responsibility to maintain all aspects of the art studio. Specific decisions fell to an annually elected management team, a small…

  13. Operating room management and operating room productivity: the case of Germany.

    Science.gov (United States)

    Berry, Maresi; Berry-Stölzle, Thomas; Schleppers, Alexander

    2008-09-01

    We examine operating room productivity on the example of hospitals in Germany with independent anesthesiology departments. Linked to anesthesiology group literature, we use the ln(Total Surgical Time/Total Anesthesiologists Salary) as a proxy for operating room productivity. We test the association between operating room productivity and different structural, organizational and management characteristics based on survey data from 87 hospitals. Our empirical analysis links improved operating room productivity to greater operating room capacity, appropriate scheduling behavior and management methods to realign interests. From this analysis, the enforcing jurisdiction and avoiding advance over-scheduling appear to be the implementable tools for improving operating room productivity.

  14. An experimental investigation of composite floor vibration due to human activities. A case study

    Directory of Open Access Journals (Sweden)

    Yasser G. Mohamed Fahmy

    2012-12-01

    Full Text Available Composite steel floor decks are used in a large variety of constructions with long spans, such as administration and commercial buildings, hotels and bridges. Due to decreased floor mass and longer span lengths, floor vibrations have become an area of concern. Floor decks with low frequencies may be in resonance with the vibrations due to human activities and the resulting acceleration may exceed human comfort levels. The design of slender floor structures, with steel or composite cross sections, is often limited by the serviceability criteria such as deflection limits and vibration behavior, rather than the strength criteria. Control of deflections under AISC specifications requirement is not enough to satisfy the serviceability requirements of the floor systems for vibration. In addition, vibration analysis procedures introduced by AISC design Guide No. 11 are based on regularly-shaped structures and simple boundary conditions. In this paper, a case study for full scale testing of a composite floor system proposed for a tower at Kuwait state that was tested prior to construction. The heel-drop and walking tests are performed on floor systems with and without raised floor respectively. Since heel-drop and walking test results would vary in light of person performance, both tests are carried out three or four times to reduce uncertainty. The fundamental frequencies and damping ratio of the floor system are measured. Comparison of the experimental results with results based on the AISC hand calculations shows that there is no significant difference; therefore the results based on AISC are generally acceptable.

  15. Radon and its short-lived decay nuclides in the living environment

    International Nuclear Information System (INIS)

    Abe, Siro

    1988-01-01

    The problem about radon and its shortlived decay nuclides in the living environment has been frequently closed-up. The problem is focused on the exposure of human being due to radon and its progeny. This paper reports the reason to the occurrence of the problem. Radon source as well as its pathway into our rooms are outlined here. The behavior of radon and its progeny indoors is also shown in this paper in comparison with outdoor situation and from the persons' activity's point of view. (author)

  16. Acoustics. Measurement of sound insulation in buildings and of building elements. Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor

    CERN Document Server

    British Standards Institution. London

    1998-01-01

    Acoustics. Measurement of sound insulation in buildings and of building elements. Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor

  17. Real-time modeling of heat distributions

    Science.gov (United States)

    Hamann, Hendrik F.; Li, Hongfei; Yarlanki, Srinivas

    2018-01-02

    Techniques for real-time modeling temperature distributions based on streaming sensor data are provided. In one aspect, a method for creating a three-dimensional temperature distribution model for a room having a floor and a ceiling is provided. The method includes the following steps. A ceiling temperature distribution in the room is determined. A floor temperature distribution in the room is determined. An interpolation between the ceiling temperature distribution and the floor temperature distribution is used to obtain the three-dimensional temperature distribution model for the room.

  18. Total Strain FE Model for Reinforced Concrete Floors on Piles

    NARCIS (Netherlands)

    Hofmeyer, H.; Bos, van den A.A.

    2008-01-01

    A finite element (FE) model using a total strain material model has been developed to predict the behavior of warehouse reinforced concrete floors on piles. The material model (not the FE model itself) was calibrated to material tests. The FE model for the floor structure was checked with full-scale

  19. Prevalence of claw disorders in Dutch dairy cows exposed to several floor systems

    NARCIS (Netherlands)

    Somers, J.G.C.J.; Frankena, K.; Noordhuizen-Stassen, E.N.; Metz, J.H.M.

    2003-01-01

    Claw health was examined in an observational study on Dutch dairy farms with either a slatted floor (SL), slatted floor with manure scraper (SL-SCR), solid concrete floor (SCF), a straw yard (SY), or a zero-grazing feeding system (ZG). Hooves of cows' hind legs were examined for the presence and

  20. The image acquisition system design of floor grinder

    Science.gov (United States)

    Wang, Yang-jiang; Liu, Wei; Liu, Hui-qin

    2018-01-01

    Based on linear CCD, high resolution image real-time acquisition system serves as designing a set of image acquisition system for floor grinder through the calculation of optical imaging system. The entire image acquisition system can collect images of ground before and after the work of the floor grinder, and the data is transmitted through the Bluetooth system to the computer and compared to realize real-time monitoring of its working condition. The system provides technical support for the design of unmanned ground grinders.

  1. Development of Claw Traits and Claw Lesions in Dairy Cows kept on different floor systems

    NARCIS (Netherlands)

    Somers, J.G.C.J.; Schouten, W.G.P.; Frankena, K.; Noordhuizen-Stassen, E.N.; Metz, J.H.M.

    2005-01-01

    Several claw shape measurements, horn hardness, and horn growth and wear were recorded monthly at 12 dairy farms to investigate the effect of floor type and changes in these traits over time. Herds were either housed on a slatted floor (SL), solid concrete floor (SC), grooved floor (GR), or on a

  2. Vivienda Unifamiliar en Sussex - Gran Bretaña

    Directory of Open Access Journals (Sweden)

    Hancock, Tom

    1978-09-01

    Full Text Available This two-storey home is located in a pleasant, thickly-wooded property overlooking the nearby valley and lake. It replaces an old manor house of the Edwardian period and incorporates existing buildings used for the help living quarters. The ground floor was arranged, distributing the kitchen area and three guest rooms, provided with independent bathrooms at either side of the receptional area, consisting of an ample drawing room and a dining room. The upper floor is reached from the ground floor through two stairways and is divided into two master bedrooms and a study room with the regular associated services. The gallery connecting the two bedrooms in the upper floor creates a double height for the drawing room below, considerably enhancing the decorative possibilities and the creation of the right atmosphere. The façades have been treated with a moderately formalistic approach, reminiscent of the English 18th century architectural style with porticos and columnated arcades.

    Esta vivienda de dos plantas se halla enclavada en una agradable finca, muy poblada de árboles, y dotada de unas magníficas vistas sobre el valle y el lago próximos. Reemplaza a una antigua mansión del período eduardino, e incorpora antiguas construcciones existentes que destina al personal de servicio. La planta baja organiza, a ambos lados de los ambientes principales —consistentes en un amplio salón con estar y un comedor—, los servicios de cocina y tres dormitorios para huéspedes dotados de baños independientes. La planta alta comunicada con la anterior mediante dos escaleras, está ocupada por dos dormitorios principales y un estudio con dependencias anexas. Una galería que da acceso a los dormitorios proporciona doble altura al salón de la planta baja, ampliando considerablemente sus posibilidades decorativas y ambientales. Las fachadas se han tratado con un planteamiento formal moderado que remeda, mediante el uso de pórticos y

  3. Regulatory Guide 1.122: Development of floor design response spectra for seismic design of floor-supported equipment or components

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    ''Reactor Site Criteria,'' requires, in part, that safety-related structures, systems, and components remain functional in the event of a Safe Shutdown Earthquake (SSE). It specifies the use of a suitable dynamic analysis as one method of ensuring that the structures, systems, and components can withstand the seismic loads. Similarly, paragraph (a)(2) of Section VI of the same appendix requires, in part, that the structures, systems, and components necessary for continued operation without undue risk to the health and safety of the public remain functional in the event of an Operating Basis Earthquake (OBE). Again, the use of suitable dynamic analysis is specified as one method of ensuring that the structures, systems, and components can withstand the seismic loads. This guide describes methods acceptable to the NRC staff for developing two horizontal and one vertical floor design response spectra at various floors or other equipment-support locations of interest from the time-history motions resulting from the dynamic analysis of the supporting structure. These floor design response spectra are needed for the dynamic analysis of the systems or equipment supported at various locations of the supporting structure

  4. [Comparison of pelvic floor muscle strength in competition-level athletes and untrained women].

    Science.gov (United States)

    Ludviksdottir, Ingunn; Hardardottir, Hildur; Sigurdardottir, Thorgerdur; Ulfarsson, Gudmundur F

    2018-01-01

    Exercise can stress the pelvic floor muscles. Numerous women experience urinary incontinence while exercising or competing in sports. This study investigated pelvic floor muscle strength, urinary incontinence, and knowledge in contracting pelvic floor muscles among female athletes and untrained women. This was a prospective case-control study measuring pelvic floor muscle strength using vaginal pressure meas-urement. Participants answered questions regarding general health, urinary incontinence, and knowledge on pelvic floor muscles. Partici-pants were healthy nulliparous women aged 18-30 years, athletes and untrained women. The athletes had competed in their sport for at least three years; including handball, soccer, gymnastics, badminton, BootCamp and CrossFit. The women were comparable in age and height. The athletes (n=18) had a body mass index (BMI) of 22.8 kg/m² vs. 25 kg/m² for the untrained (n=16); p<0.05. The athletes trained on average 11.4 hours/week while the untrained women participated in some activity on average for 1.3 hours/week; p< 0.05. Mean pelvic floor strength was 45±2 hPa in the athletes vs. 43±4 hPa in the untrained; p=0.36 for whether the athletes were stronger. Of the athletes, 61.1% experienced urinary incontinence (n=11) compared with 12.5% of the untrained women (n=2); p<0.05. Incontinence usually occurred during high intensity exercise. The athletes were more knowledgeable about the pelvic floor muscles; p<0.05. There was not a significant difference in the strength of pelvic floor muscles of athletes and untrained women. This suggests that pelvic floor muscles are not strengthened during general training but require specific exercises. This holds especially for football, handball and sports with high physical intensity. Coaches need to pay special attention to training and strengthening women's pelvic floor muscles to reduce the occurrence of urinary incontinence.

  5. Effect of pelvic floor muscle exercises on pulmonary function

    OpenAIRE

    Han, DongWook; Ha, Misook

    2015-01-01

    [Purpose] This study aimed to determine the correlation between pelvic floor muscle strength and pulmonary function. In particular, we examined whether pelvic floor muscle exercises can improve pulmonary function. [Subjects] Thirty female college students aged 19?21 with no history of nervous or musculoskeletal system injury were randomly divided into experimental and control groups. [Methods] For the pulmonary function test, spirometry items included forced vital capacity and maximal volunta...

  6. Timber floors strengthened with concrete

    NARCIS (Netherlands)

    Blass, H.J.; Linden, M.L.R. van der; Schlager, M.

    1998-01-01

    Timber-concrete composite (tcc) beams may be used for the renovation of old timber floors. Although these systems are not new (Pokulka, 1997) and form a simple and practical solution, they are not widely adopted. One of the reasons for this is the Jack of uniform design rules. In this research

  7. Timber-concrete composite floor systems

    NARCIS (Netherlands)

    Linden, M.L.R. van der; Blass, H.J.

    1996-01-01

    Timber-concrete composite (tcc) beams may be used for the renovation of old timber floors. Although these systems are a simple and practical solution, they are not widely adopted. One of the reasons for this is the lack of uniform design mies. In this research programme shear tests on four different

  8. Efficacy of hypopressive abdominal gymnastics in rehabilitating the pelvic floor of women: A systematic review.

    Science.gov (United States)

    Ruiz de Viñaspre Hernández, R

    2017-12-13

    Hypopressive abdominal gymnastics has been proposed as a new paradigm in rehabilitating the pelvic floor. Its claims contraindicate the recommendation for pelvic floor muscle training during the postpartum period. To determine whether hypopressive abdominal gymnastics is more effective than pelvic floor muscle training or other alternative conservative treatments for rehabilitating the pelvic floor. We consulted the databases of the Cumulative Index to Nursing and Allied Health Literature (CINAHL), the Cochrane Library, Latin American and Caribbean Health Sciences Literature (LILACS), Physiotherapy Evidence Database (PEDro), PubMed, Scopus, Trip Database and Web of Science. We selected systematic reviews, clinical trials and analytical studies that assessed the efficacy of hypopressive abdominal gymnastics in women. The measured outcomes were the strengthening of the pelvic floor muscles, the incidence of urine incontinence or prolapse and symptom remission. We included 4 clinical trials, whose quality was measured with the PEDro scale. Hypopressive gymnastics is less effective than pelvic floor muscle training for activating pelvic floor muscles, achieving closure of the levator hiatus of the anus and increasing pelvic floor muscle thickness, strength and resistance. The evidence reviewed does not support the recommendation for hypopressive abdominal gymnastics for strengthening the pelvic floor either during the postpartum period or outside that period. Pelvic floor muscle training remains the first-line treatment for pelvic floor dysfunction. There is a lack of quality clinical trials that have evaluated the efficacy of hypopressive abdominal gymnastics. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Vivienda en Oferdingen - Alemania Federal

    Directory of Open Access Journals (Sweden)

    Haug, W.

    1973-04-01

    Full Text Available This house consists of three floors: — ground floor with vertical walls, and — two upper floors with a sloping roofing. The ground floor houses the bedrooms, children's playroom, bathroom and toilet, dining-room, kitchen, drawing-room and a little covered courtyard inside the house. The first floor comprises a big living-room connected with the drawing-room with chimney, as well as the wife's work room. The father's studio-workshop is at the second floor or gallery. Almost all the construction is of wood, with loadbearing units which support a series of roof assymetric trusses in wood. The sloping roof consists of eternit units over wood boarding, with intermediate insulating material. The same type of construction is used for the upper part of exterior walls, and light-weight concrete for the lower part. The floors, chimney and stair wall are of reinforced concrete. Slag-made slabs are used for service area, and sisal-fibre moquette for the rest of the house. Timber is used for ceilings and staircases. The windows are made of fir wood carpentry with insulating panes.Esta vivienda se ha dispuesto en tres niveles: planta baja normal, de paredes verticales, y dos superiores, limitadas por la cubierta inclinada. La planta baja consta de: dormitorios, cuarto de juego para niños, baño y aseo, comedor, cocina, estancia, y un pequeño patio cubierto, en la zona interior de la casa. En la planta superior se ha dispuesto una gran sala de estar comunicada con la estancia de la chimenea, y un cuarto de trabajo para la señora. El último nivel o galería aloja un taller-estudio para el padre. La construcción es, casi en su totalidad, de madera, a base de elementos resistentes, sobre los que apoyan una serie de cerchas asimétricas, también de madera, que sostienen la cubierta inclinada, compuesta por piezas de Eternit sobre entablado de madera, con material aislante intermedio. Este mismo tipo de construcción se emplea en la parte superior de los

  10. Centro escolar para estudiantes. Vancouver

    Directory of Open Access Journals (Sweden)

    Thompson, Berwick & Pratt, Arquitectos

    1965-05-01

    Full Text Available This centre has four storeys. On the same level as the garden, the main building has a large recreation room, the canteen and auxiliary rooms, also the secretary's office, a room for the housekeeper, and washrooms. A carpark, the gardener's house, a workshop and a storehouse are also situated close by. The second floor, which is level with the patio facing the main entrance, has a main hall, a meeting room and offices. The third floor is taken up with the library, a lounge, and bar, as well as secondary rooms. Living quarters are provided in the attic.El edificio se desarrolla en cuatro plantas. En el nivel del jardín el cuerpo de la edificación principal aloja: el salón de recreo, la cantina con sus dependencias auxiliares, la secretaria, una oficina, cuarto del ama de llaves, aseos, etc.; en este nivel han sido construidos asimismo: estacionamiento de coches, la vivienda del jardinero, taller y almacén. La planta a nivel del patio de entrad alberga: el vestíbulo principal, salón de reuniones y una oficina. La plañía principal cobija: la biblioteca, salón, bar con sus correspondientes dependencias anexas—, etc. El ático está ocupado por una vivienda.

  11. Effects of maxillary sinus floor elevation surgery on maxillary sinus physiology

    NARCIS (Netherlands)

    Timmenga, NM; Raghoebar, GM; Liem, RSB; van Weissenbruch, R; Manson, WL; Vissink, A

    In a prospective study, the effects of elevation surgery of the maxillary sinus floor on maxillary sinus physiology were assessed. Seventeen consecutive patients without preoperative anamnestic, clinical and radiological signs of maxillary sinusitis underwent sinus floor elevation surgery with iliac

  12. The influence of body mass index and gender on the impact attenuation properties of flooring systems.

    Science.gov (United States)

    Bhan, Shivam; Levine, Iris; Laing, Andrew C

    2013-12-01

    The biomechanical effectiveness of safety floors has never been assessed during sideways falls with human volunteers. Furthermore, the influence of body mass index (BMI) and gender on the protective capacity of safety floors is unknown. The purpose of this study was to test whether safety floors provide greater impact attenuation compared with traditional flooring, and whether BMI and gender modify their impact attenuation properties. Thirty participants (7 men and 7 women of low BMI; 7 men and 9 women of high BMI) underwent lateral pelvis release trials on 2 common floors and 4 safety floors. As a group, the safety floors reduced peak force (by up to 11.7%), and increased the time to peak force (by up to 25.5%) compared with a traditional institutional grade floor. Force attenuation was significantly higher for the low BMI group, and for males. Force attenuation was greatest for the low BMI males, averaging 26.5% (SD = 3.0) across the safety floors. These findings demonstrate an overall protective effect of safety floors during lateral falls on the pelvis, but also suggest augmented benefits for frail older adults (often with low body mass) who are at an increased risk of hip fracture.

  13. User Identification Using Gait Patterns on UbiFloorII

    Science.gov (United States)

    Yun, Jaeseok

    2011-01-01

    This paper presents a system of identifying individuals by their gait patterns. We take into account various distinguishable features that can be extracted from a user’s gait and then divide them into two classes: walking pattern and stepping pattern. The conditions we assume are that our target environments are domestic areas, the number of users is smaller than 10, and all users ambulate with bare feet considering the everyday lifestyle of the Korean home. Under these conditions, we have developed a system that identifies individuals’ gait patterns using our biometric sensor, UbiFloorII. We have created UbiFloorII to collect walking samples and created software modules to extract the user’s gait pattern. To identify the users based on the gait patterns extracted from walking samples over UbiFloorII, we have deployed multilayer perceptron network, a feedforward artificial neural network model. The results show that both walking pattern and stepping pattern extracted from users’ gait over the UbiFloorII are distinguishable enough to identify the users and that fusing two classifiers at the matching score level improves the recognition accuracy. Therefore, our proposed system may provide unobtrusive and automatic user identification methods in ubiquitous computing environments, particularly in domestic areas. PMID:22163758

  14. A Summary--The Economics of Carpeting and Resilient Flooring. An Evaluation and Comparison.

    Science.gov (United States)

    Parks, George M.

    Of use to those concerned with the economics of flooring selection and maintenance, this comparison may prove useful as an estimating guide in the preparation of cost estimates for any flooring area where economics is a factor in the choice of materials. All costs attributed to carpet or resilient flooring have been obtained either by survey or…

  15. 76 FR 76690 - Multilayered Wood Flooring From the People's Republic of China: Amended Final Determination of...

    Science.gov (United States)

    2011-12-08

    ... construction or locking joints). All multilayered wood flooring is included within the definition of the... DEPARTMENT OF COMMERCE International Trade Administration [A-570-970] Multilayered Wood Flooring... is issuing an antidumping duty order on multilayered wood flooring (``wood flooring'') from the...

  16. Effect of rubber flooring on group-housed sows' gait and claw and skin lesions.

    Science.gov (United States)

    Bos, E-J; van Riet, M M J; Maes, D; Millet, S; Ampe, B; Janssens, G P J; Tuyttens, F A M

    2016-05-01

    This study evaluated the influence of floor type on sow welfare in terms of lameness, claw lesions, and skin lesions. In a 2 × 3 factorial design, we have investigated the effect of rubber coverings on concrete floors and the effect of 3 levels of dietary zinc supplementation on locomotion and claw and skin lesions in group-housed sows. Six groups of 21 ± 4 hybrid sows were monitored during 3 successive reproductive cycles. The sows were group housed from d 28 after insemination (d 0) until 1 wk before expected farrowing date (d 108) in pens with either exposed concrete floors or concrete floors covered with rubber in part of the lying area and the fully slatted area. During each reproductive cycle, locomotion and skin lesions were assessed 4 times (d 28, 50, 108, and 140) and claw lesions were assessed twice (d 50 and 140). Results are given as least squares means ± SE. Locomotion and claw scores were given in millimeters, on analog scales of 150 and 160 mm, respectively. Here, we report on the effect of floor type, which did not interact with dietary zinc concentration ( > 0.10 for all variables). At move to group (d 28) and mid gestation (d 50), no differences between floor treatments were seen in locomotion ( > 0.10). At the end of gestation (d 108), sows housed on rubber flooring scored 9.9 ± 4.1 mm better on gait ( flooring at mid gestation (d 50). However, sows on rubber flooring scored worse for "vertical cracks in the wall horn" (difference of 3.4 ± 1.7 mm; = 0.04). At the end of lactation (d 140), both "white line" (difference of 2.9 ± 1 mm; = 0.02) and "claw length" (difference of 4.7 ± 1.4 mm; flooring. No differences for skin lesions were observed between floor treatments. The improved scores for gait toward the end of gestation and some types of claw disorders at mid gestation suggest that rubber flooring in group housing has a beneficial effect on the overall leg health of sows. The documented increase in vertical cracks in the wall horn at d

  17. Friction between footwear and floor covered with solid particles under dry and wet conditions.

    Science.gov (United States)

    Li, Kai Way; Meng, Fanxing; Zhang, Wei

    2014-01-01

    Solid particles on the floor, both dry and wet, are common but their effects on the friction on the floor were seldom discussed in the literature. In this study, friction measurements were conducted to test the effects of particle size of solid contaminants on the friction coefficient on the floor under footwear, floor, and surface conditions. The results supported the hypothesis that particle size of solids affected the friction coefficient and the effects depended on footwear, floor, and surface conditions. On dry surfaces, solid particles resulted in friction loss when the Neolite footwear pad was used. On the other hand, solid particles provided additional friction when measured with the ethylene vinyl acetate (EVA) footwear pad. On wet surfaces, introducing solid particles made the floors more slip-resistant and such effects depended on particle size. This study provides information for better understanding of the mechanism of slipping when solid contaminants are present.

  18. Analytical model and application of stress distribution on mining coal floor

    Institute of Scientific and Technical Information of China (English)

    ZHU Shu-yun; JIAN Zhen-quan; HOU Hong-liang; XIAO Wei-guo; YAO Pu

    2008-01-01

    Given the analysis of underground pressure, a stress calculation model of coal floor stress has been established based on a theory of elasticity. The model presents the law of stress distribution on the relatively fixed position of the mining coal floor: the extent of stress variation in a fixed floor position decreases gradually along with depth, the decreasing rate of the vertical stress is clearly larger than that of the horizontal stress at a specific depth. The direction of the maximum principal stress changes gradually from a vertical direction to a horizontal direction with the advance of the working face. The deformation and permeability of the rock mass of the coal floor are obtained by contrasting the difference of the principal stress established from theoretical calculations with curves of stress-strain and permeability-strain from tests, which is an important mechanical basis for preventing water inrush from confined aquifers.

  19. Defect characterization, diagnosis and repair of wood flooring based on a field survey

    International Nuclear Information System (INIS)

    Delgado, A.; Pereira, C.; Brito, J. de; Silvestre, J.D.

    2018-01-01

    A statistical characterization of defects in 35 buildings and 98 wood floorings (softwood and hardwood floors, and laminated and engineered wood floors), their diagnostic methods and repair solutions is presented. An expert system for inspecting wood flooring, comprising the classification of defects, their most probable causes, diagnostic methods and repair techniques, was used. Results include age, affected area, severity and frequency of defects and their main causes, as well as appropriate diagnostic methods, preventive and curative repair solutions most prescribed and the most significant correlations. Scratches were detected in more than five sixths of the sample, highly associated with exterior mechanical actions, and with an inadequate finishing layer. Wearing of the finishing layer was detected in a quarter of the inspected floorings. Accordingly, the application of a suitable finishing layer and, alternatively, its replacement are the most prescribed repair techniques. [es

  20. Hypoxia Room

    Data.gov (United States)

    Federal Laboratory Consortium — The Hypoxia Room is a 8x8x8 ft. clear vinyl plastic and aluminum frame construction enclosure located within USAREIM laboratory 028. The Hypoxia Room (manufactured...

  1. Is Pelvic Floor Muscle Training Effective for Men With Poststroke Lower Urinary Tract Symptoms?

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Gard, Gunvor; Dehlendorff, Christian

    2017-01-01

    The aim of the current study was to evaluate the effect of pelvic floor muscle training in men with poststroke lower urinary tract symptoms. Thirty-one poststroke men, median age 68 years, were included in this single-blinded randomized controlled trial. Thirty participants, 15 in each group......, completed the study. The intervention consisted of 3 months (12 weekly sessions) of pelvic floor muscle training in groups and home exercises. The effect was evaluated by the DAN-PSS-1 (Danish Prostate Symptom Score) questionnaire, a voiding diary, and digital anal palpation of the pelvic floor muscle...... that pelvic floor muscle training has an effect for lower urinary tract symptoms, although statistical significance was only seen for pelvic floor muscle....

  2. Evolution Sustainable Green Inner-wall with Flexible Floor Plan

    Directory of Open Access Journals (Sweden)

    Tawil N.M.

    2014-01-01

    Full Text Available The trend of renovate residential houses especially the interior of the house has become a common phenomenon for homeowners nowadays in Malaysia. This scenario is quiet concern because sometimes no modifications to comply with the law and the guidelines set by the government housing. Modifications with not done properly can cause injury and harm to families and the people around. To reduce this problem, the concept of sustainable inner walls with flexible floor plan should be incorporated in every house in Malaysia. This is because the wall is the basic structure of a building and usually serves as the border, supporting structures and dividing the space with another space. Wall also causes an increase of the price of a house. This is due to the increase in raw material costs and labor costs, land subsidence have to bear by the developer. The increasing in house prices is causing among Malaysians, especially young executives cannot afford to buy their first home. To reduce the price of the home, reduction in construction interior wall in wet construction should be done and replaced with the sustainable inner wall. This sustainable inner wall also can save the space and the owner simplify can added or reduced the room according their need without spending too much money for renovation in the future.

  3. Pelvic Floor Muscle Training: Underutilization in the USA.

    Science.gov (United States)

    Lamin, Eliza; Parrillo, Lisa M; Newman, Diane K; Smith, Ariana L

    2016-02-01

    Pelvic floor disorders are highly prevalent in women of all ages and can greatly impair quality of life. Pelvic floor muscle training (PFMT) is a viable treatment option for several pelvic floor conditions including urinary incontinence and pelvic organ prolapse. PFMT is a program of therapy initiated by an experienced clinician (e.g., women's health or urology nurse practitioner (NP), physical therapist (PT)) that involves exercises for women with stress urinary incontinence (UI) and exercises combined with behavioral or conservative treatments (lifestyle changes, bladder training with urge suppression) for women with urgency or mixed UI. These exercise programs are more comprehensive than simple Kegel exercises. Despite evidence-based research indicating the efficacy and cost-effectiveness for treatment of urinary incontinence, PFMT is not commonly used as a first-line treatment in clinical practice in the USA (Abrams et al., 2012). This article will review PFMT for the treatment of UI and pelvic organ prolapse (POP) and theorize how this conservative therapy can be utilized more effectively in the USA.

  4. Maxillary sinus floor elevation surgery - A clinical, radiographic and endoscopic evaluation

    NARCIS (Netherlands)

    Timmenga, NM; Raghoebar, GM; van Weissenbruch, R; Vissink, A

    Although augmentation of the maxillary sinus floor with autogenous bone grafts has become a well established preimplantology procedure, its effect on the function of the maxillary sinus has not been the subject of prospective human studies. In this prospective study the effects of sinus floor

  5. Reconstruction of Orbital Floor With Auricular Concha.

    Science.gov (United States)

    Seven, Ergin; Tellioglu, Ali Teoman; Inozu, Emre; Ozakpinar, Hulda Rifat; Horoz, Ugur; Eryilmaz, Avni Tolga; Karamursel, Sebat

    2017-10-01

    Orbital floor fractures of varying sizes commonly occur after orbital injuries and remain a serious challenge. Serious complications of such fractures include enopthalmos, restriction of extraocular movement, and diplopia. There is a dearth of literature that can be applied widely, easily, and successfully in all such situations, and therefore there is no consensus on the treatment protocol of this pathology yet. Autogenous grafts and alloplastic and allogenic materials with a wide variety of advantages and disadvantages have been discussed. The value of preoperative and postoperative ophthalmological examination should be standard of care in all orbital fracture patients. An ideal reconstructed orbital floor fracture should accelerate the restoration of orbital function with acceptable cosmetic results. Management parameters of orbital fractures such as timing of surgery, incision type, and implant materials, though widely discussed, remain controversial. In this study, 55 patients with orbital floor fractures surgically reconstructed with conchal cartilage grafts between 2008 and 2014 were retrospectively evaluated. Complications and long-time follow-up visit results have been reported with clinical and radiographic findings. The aim of this study was to present the authors' clinical experiences of reconstruction of blow-out fractures with auricular conchal graft and to evaluate the other materials available for use.

  6. Correlation study regarding the pelvic floor hypotonia in relation to labour, age and number of births

    Directory of Open Access Journals (Sweden)

    Doriana Ioana CIOBANU

    2017-03-01

    Full Text Available Background. During pregnancy, there is an increased pressure on pelvic floor. During labour and delivery the pelvic floor is stretched and can be damaged, leading to urine leakage, mostly during laughing, sneezing, coughing, running. This condition is called urinary incontinence. Aim. This paperwork aims to emphasize if there is a significant correlation between labor parameters, age, number of deliveries and the presence of pelvic floor hypotonia and urinary incontinence in women, after delivery. Material and method. Study was made on 24 women in the first days after delivery, ages between 21- 42 years old. 66,7% are primiparous, 33,3% are multiparous. As the assessment tools were used: stop urine test, number of perineal muscle contractions, questionnaire regarding the presence of urge urinary incontinence. Results. From the total number of subjects, 33.3% have stress incontinence and 29.2% have urge incontinence. There is a significant correlation between the presence of urinary incontinence and living environment [p = 0,014, (df. = 1], smoking [p = 0,014], the onset of labor [p = 0,014], administration of antispaspasmodic medication in labor [p = 0,010], administration of antialgic medication [p = 0,014] and the duration of delivery period [p = 0,028]. Conclusions. From the 24 subjects, 62,5% of them have urinary incontinence after labor and delivery. From these, 33.3% have stress incontinence, and 29.2% have urge incontinence. After labor and delivery more affected are fast fibers of perineal muscles, responsible withholding the urine during coughing, sneezing, lifting objects, going upstairs, as well as withholding the urine in case of overflow bladder. After labor and delivery, most women have hypotonia of perineal muscles.

  7. Maple Flooring - How Architects View it

    Science.gov (United States)

    Gary R. Lindell

    1971-01-01

    In a study of architects'' opinions of maple flooring versus vinyl asbestos tile for school gymnasuims, resiliency and durability were found to be important factors favoring maple whereas vinyl asbestos tile was felt to be less costly and more dimesionally stable.

  8. Radiant floor cooling coupled with dehumidification systems in residential buildings: A simulation-based analysis

    International Nuclear Information System (INIS)

    Zarrella, Angelo; De Carli, Michele; Peretti, Clara

    2014-01-01

    Highlights: • The floor radiant cooling in a typical apartment is analyzed. • Dehumidification devices, fan-coil and mechanical ventilation are compared. • The results are analyzed in terms of both thermal comfort and energy consumption. • The energy consumption of the dehumidifiers is higher than that of other systems. • The mechanical ventilation decreases the moisture level better than other systems. - Abstract: The development of radiant cooling has stimulated an interest in new systems based on coupling ventilation with radiant cooling. However, radiant cooling systems may cause condensation to form on an active surface under warm and humid conditions during the cooling season. This phenomenon occurs when surface temperature falls below dew point. To prevent condensation, air humidity needs to be reduced with a dehumidification device or a mechanical ventilation system. There are two main options to achieve this. The first is to use dehumidification devices that reduce humidity, but are not coupled with ventilation, i.e. devices that handle room air and leave air change to infiltrations. The second is to combine a mechanical ventilation system with dehumidifying finned coils. This study analyzes the floor radiant cooling of a typical residential apartment within a multi-storey building in three Italian climate zones by means of a detailed simulation tool. Five systems were compared in terms of both indoor thermal comfort and energy consumption: radiant cooling without dehumidification; radiant cooling with a soft dehumidification device; radiant cooling with a dehumidification device which also supplies sensible cooling; radiant cooling coupled with fan coils; and radiant cooling with a mechanical ventilation system which dehumidifies and cools

  9. Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

    Science.gov (United States)

    Geertsema, Roger S; Lindsell, Claire E

    2015-09-01

    When IVC are directly exhausted from a rodent housing room, the air quality of the room can become independent of the intracage air quality and may reduce the need for high room ventilation rates. This study assessed the effect of decreasing the ventilation rate in rodent rooms using direct-exhaust IVC systems. The study was conducted over 16 wk and compared conditions in 8 rodent rooms that had ventilation rates of 5 to 6 air changes per hour (ACH) with those in rooms at 10 to 12 ACH. At the low ventilation rate, rooms had higher CO₂ concentrations, higher dew point temperature, and lower particulate levels and spent a greater percentage of time above the temperature set point than did rooms at the high rate. The levels of allergens and endotoxins in room air were the same regardless of the ventilation rate. Differences seen in parameters within cages at the 2 ventilation rates were operationally irrelevant. We detected no total volatile organic compounds in the room that were attributable to ammonia, regardless of the ventilation rate. Clearing the air of ethanol after a spill took longer at the low compared with high rate. However, ethanol clearance was faster at the low rate when the demand-control system was activated than at the high ventilation rate alone. Air quality in the room and in the cages were acceptable with room ventilation rates of 5 to 6 ACH in rodent rooms that use direct-exhaust IVC systems.

  10. Use of radiometer to reform and repair an old living house to passive solar one

    Science.gov (United States)

    Okamoto, Yoshizo; Inagaki, Terumi; Suzuki, Takakazu; Kurokawa, Takashi

    1994-03-01

    Japanese living houses mainly consist of wooden elements in high-temperature and moist conditions. To modify the hot and humid environment, a conventional old house was partially rebuilt and repaired. Especially in the winter season, a diagnostic thermographic test was used to find deteriorated and leaking parts of interior and exterior walls. Macroscopic deteriorated parts were checked again in detail. The deteriorated element was then removed. During the reconstruction process, a new solar heat and air conditioning system using a silica-gel adsorber and underground water was installed to cool and warm up the living room. Thermography tests of this remodeled house show that room temperature is always constant and mild to human beings, especially in the winter. Temperature and heat flow distribution of flowing air in the living room was measured using thermal net and wire methods. Leaking thermal streak flow of the gap was locally visualized by the IR radiometer and a highly sensitive video camera. It was verified that IR thermography is a useful measuring instrument to check thermal defects of a house.

  11. Pelvic Floor Physical Therapy as Primary Treatment of Pelvic Floor Disorders With Urinary Urgency and Frequency-Predominant Symptoms.

    Science.gov (United States)

    Adams, Sonia R; Dessie, Sybil G; Dodge, Laura E; Mckinney, Jessica L; Hacker, Michele R; Elkadry, Eman A

    2015-01-01

    To assess the efficacy of pelvic floor physical therapy (PFPT) as primary treatment of urinary urgency and frequency symptoms We conducted a prospective cohort study of women with urinary urgency and frequency symptoms. Participants underwent PFPT once or twice per week for 10 weeks. Symptom improvement was assessed by validated questionnaires (Pelvic Floor Distress Inventory-Short Form 20 and Patient Global Impression of Improvement), voiding diaries, and subjective measures. Fifty-seven participants enrolled; 21 (36.8%) withdrew or completed less than 5 weeks of PFPT. Thirty-one (54.4%) of the remaining 36 participants completed 10 weeks of PFPT. The mean age of the study group (n = 36) was 48.9 ± 15.0 years. The primary diagnoses were overactive bladder syndrome (n = 24, 66.7%) and painful bladder syndrome (n = 12, 33.3%). Women attended a median of 14.0 (interquartile range [IQR], 8.0-16.0) PFPT visits over a median of 11.9 weeks (IQR, 10.0-18.1). At baseline, the median Pelvic Floor Distress Inventory-Short Form 20 score was 79.2 (IQR, 53.1-122.9), and decreased to 50.0 (IQR, 25.0-88.5; P therapies. The high dropout rates suggest that motivation or logistic factors may play a significant role in the utilization and success of this treatment option.

  12. Pelvic floor muscle problems mediate sexual problems in young adult rape victims.

    Science.gov (United States)

    Postma, Riemke; Bicanic, Iva; van der Vaart, Huub; Laan, Ellen

    2013-08-01

    Prior studies have addressed sexual abuse and sexual function in adult women. No studies have focused on the effect of adolescence rape on sexual functioning. To investigate the effect of rape on sexual problems and on pelvic floor problems, as well as the mediating role of pelvic floor problems on sexual problems, in a homogenous group of victims of adolescence rape without a history of childhood sexual, physical, and/or emotional abuse. Sexual functioning and pelvic floor functioning were assessed using self-report questionnaires. In this cross-sectional study, a group of 89 young women aged 18-25 years who were victimized by rape in adolescence was compared with a group of 114 nonvictimized controls. The rape victims were treated for posttraumatic stress disorder (PTSD) 3 years prior to participation in the study. Three years posttreatment, rape victims were 2.4 times more likely to have a sexual dysfunction (lubrication problems and pain) and 2.7 times more likely to have pelvic floor dysfunction (symptoms of provoked vulvodynia, general stress, lower urinary tract, and irritable bowel syndrome) than nonvictimized controls. The relationship between rape and sexual problems was partially mediated by the presence of pelvic floor problems. Rape victims and controls did not differ with regard to sexual activities. Rape victims suffer significantly more from sexual dysfunction and pelvic floor dysfunction when compared with nontraumatized controls, despite the provision of treatment for PTSD. Possibly, physical manifestations of PTSD have been left unaddressed in treatment. Future treatment protocols should consider incorporating (physical or psychological) treatment strategies for sexual dysfunction and/or pelvic floor dysfunction into trauma exposure treatments. © 2013 International Society for Sexual Medicine.

  13. Contribution of pelvic floor muscles to stiffness of the pelvic ring

    NARCIS (Netherlands)

    Pool-Goudzwaard, A.L.; Hoek van Dijke, G; van Gurp, M; Mulder, P; Snijders, C.J.; Stoeckart, R.

    2004-01-01

    STUDY DESIGN: A biomechanical study in embalmed specimens, on the relation between applied tension in the pelvic floor muscles, stiffness of the pelvic ring and generation of movement in the sacroiliac joints. OBJECTIVE: To gain insight into the effect of tension in the pelvic floor muscles on

  14. Statistical Analysis Of Tank 19F Floor Sample Results

    International Nuclear Information System (INIS)

    Harris, S.

    2010-01-01

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 19F as per the statistical sampling plan developed by Harris and Shine. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL95%) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current scrape sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 19F. The uncertainty is quantified in this report by an UCL95% on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL95% was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  15. Room temperature superconductors

    International Nuclear Information System (INIS)

    Sleight, A.W.

    1995-01-01

    If the Holy Grail of room temperature superconductivity could be achieved, the impact on could be enormous. However, a useful room temperature superconductor for most applications must possess a T c somewhat above room temperature and must be capable of sustaining superconductivity in the presence of magnetic fields while carrying a significant current load. The authors will return to the subject of just what characteristics one might seek for a compound to be a room temperature superconductor. 30 refs., 3 figs., 1 tab

  16. Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?

    Science.gov (United States)

    Stella, Judith; Hurt, Moriah; Bauer, Amy; Croney, Candace

    2018-01-01

    Simple Summary It is important to understand how the flooring substrate used in dog housing impacts dog health and well-being. Aspects to consider include paw, elbow, and hock health, the cleanliness of the dog, and the ability of the floors to be cleaned easily and thoroughly. This pilot study assessed the health and cleanliness of 118 dogs housed on three different types of flooring commonly found in commercial breeding kennels. No serious paw, elbow, or hock problems were identified. Thirty-one percent or fewer kennels at each facility were found to have fecal contamination after routine cleaning and the majority of dogs were clean. These findings indicate that a well-managed kennel can maintain clean, healthy dogs on different types of flooring substrates. Abstract Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli. Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring

  17. Myofascial pain and pelvic floor dysfunction in patients with interstitial cystitis.

    Science.gov (United States)

    Bassaly, Renee; Tidwell, Natalie; Bertolino, Siobhan; Hoyte, Lennox; Downes, Katheryne; Hart, Stuart

    2011-04-01

    The objectives of this study are to investigate myofascial pain in patients with interstitial cystitis (IC) and to correlate myofascial exam findings with validated questionnaires. A retrospective chart review was performed on 186 patients with a diagnosis of IC from April 2007 to December 2008. Demographics, history and physical examination, and validated pelvic floor dysfunction questionnaire scores were extracted. The data was evaluated with SPSS for Windows using Spearman's rho, Mann-Whitney, and Kruskal-Wallis statistical analyses. Myofascial pain was demonstrated in 78.3% of IC patients with at least one myofascial trigger point, and 67.9% of patients had numerous areas of trigger points. Mild correlations were seen with trigger points and scores from the PUF, PFDI-20, and PFIQ-7 questionnaires. Myofascial pain is prevalent among IC patients and positively correlated with pelvic floor dysfunction scores. These findings support evaluation of pelvic floor myofascial pain in IC patients and suggest a possible benefit from pelvic floor therapy.

  18. Flooring for Schools: Unsightly Walkways

    Science.gov (United States)

    Baxter, Mark

    2011-01-01

    Many mattress manufacturers recommend that consumers rotate their mattresses at least twice a year to help prevent soft spots from developing and increase the product's life span. It's unfortunate that the same kind of treatment can't be applied to flooring for schools, such as carpeting, especially in hallways. Being able to flip or turn a carpet…

  19. Bioelectrical activity of the pelvic floor muscles after 6-week biofeedback training in nulliparous continent women.

    Science.gov (United States)

    Chmielewska, Daria; Stania, Magdalena; Smykla, Agnieszka; Kwaśna, Krystyna; Błaszczak, Edward; Sobota, Grzegorz; Skrzypulec-Plinta, Violetta

    2016-01-01

    The aim of the study was to evaluate the effects of a 6-week sEMG-biofeedback-assisted pelvic floor muscle training program on pelvic floor muscle activity in young continent women. Pelvic floor muscle activity was recorded using a vaginal probe during five experimental trials. Biofeedback training was continued for 6 weeks, 3 times a week. Muscle strenghtening and endurance exercises were performed alternately. SEMG (surface electromyography) measurements were recorded on four different occasions: before training started, after the third week of training, after the sixth week of training, and one month after training ended. A 6-week sEMG-biofeedback-assisted pelvic floor muscle training program significantly decreased the resting activity of the pelvic floor muscles in supine lying and standing. The ability to relax the pelvic floor muscles after a sustained 60-second contraction improved significantly after the 6-week training in both positions. SEMG-biofeedback training program did not seem to affect the activity of the pelvic floor muscles or muscle fatigue during voluntary pelvic floor muscle contractions. SEMG-biofeedback-assisted pelvic floor muscle training might be recommended for physiotherapists to improve the effectiveness of their relaxation techniques.

  20. Physical activity and the pelvic floor.

    Science.gov (United States)

    Nygaard, Ingrid E; Shaw, Janet M

    2016-02-01

    Pelvic floor disorders are common, with 1 in 4 US women reporting moderate to severe symptoms of urinary incontinence, pelvic organ prolapse, or fecal incontinence. Given the high societal burden of these disorders, identifying potentially modifiable risk factors is crucial. Physical activity is one such potentially modifiable risk factor; the large number of girls and women participating in sport and strenuous training regimens increases the need to understand associated risks and benefits of these exposures. The aim of this review was to summarize studies reporting the association between physical activity and pelvic floor disorders. Most studies are cross-sectional and most include small numbers of participants. The primary findings of this review include that urinary incontinence during exercise is common and is more prevalent in women during high-impact sports. Mild to moderate physical activity, such as brisk walking, decreases both the odds of having and the risk of developing urinary incontinence. In older women, mild to moderate activity also decreases the odds of having fecal incontinence; however, young women participating in high-intensity activity are more likely to report anal incontinence than less active women. Scant data suggest that in middle-aged women, lifetime physical activity increases the odds of stress urinary incontinence slightly and does not increase the odds of pelvic organ prolapse. Women undergoing surgery for pelvic organ prolapse are more likely to report a history of heavy work than controls; however, women recruited from the community with pelvic organ prolapse on examination report similar lifetime levels of strenuous activity as women without this examination finding. Data are insufficient to determine whether strenuous activity while young predisposes to pelvic floor disorders later in life. The existing literature suggests that most physical activity does not harm the pelvic floor and does provide numerous health benefits for

  1. Room acoustics modeling using a point-cloud representation of the room geometry

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    Room acoustics modeling is usually based on the room geometry that is parametrically described prior to a sound transmission calculation. This is a highly room-specific task and rather time consuming if a complex geometry is to be described. Here, a run time generic method for an arbitrary room...... geometry acquisition is presented. The method exploits a depth sensor of the Kinect device that provides a point based information of a scanned room interior. After post-processing of the Kinect output data, a 3D point-cloud model of the room is obtained. Sound transmission between two selected points...... level of user immersion by a real time acoustical simulation of a dynamic scenes....

  2. Biomimetic matrices for pelvic floor repair

    NARCIS (Netherlands)

    Vashaghian, M.

    2017-01-01

    Pelvic organ prolapsed (POP) is a dysfunctional disease in female pelvic floor that affects a lot of women worldwide, and reduces their quality of life. Currently, trans-vaginal knitted polypropylene meshes are used as secondary treatment, for anatomical correction of the dysfunctional tissues.

  3. The floor effect: impoverished spatial memory for elevator buttons.

    Science.gov (United States)

    Vendetti, Michael; Castel, Alan D; Holyoak, Keith J

    2013-05-01

    People typically remember objects to which they have frequently been exposed, suggesting that memory is a by-product of perception. However, prior research has shown that people have exceptionally poor memory for the features of some objects (e.g., coins) to which they have been exposed over the course of many years. Here, we examined how people remember the spatial layout of the buttons on a frequently used elevator panel, to determine whether physical interaction (rather than simple exposure) would ensure the incidental encoding of spatial information. Participants who worked in an eight-story office building displayed very poor recall for the elevator panel but above-chance performance on a recognition test. Performance was related to how often and how recently the person had used the elevator. In contrast to their poor memory for the spatial layout of the elevator buttons, most people readily recalled small distinctive graffiti on the elevator walls. In a more implicit test, the majority were able to locate their office floor and the eighth floor button when asked to point toward these buttons when in the actual elevator, with the button labels covered. However, identification was very poor for other floors (including the first floor), suggesting that even frequent interaction with information does not always lead to accurate spatial memory. These findings have implications for understanding the complex relationships among attention, expertise, and memory.

  4. TUGAS ROOM ATTENDANT DALAM MENANGANI COMPLAINT TAMU DELUXE ROOM HOTEL HYAAT REGENCY BANDUNG

    Directory of Open Access Journals (Sweden)

    Reza Gustia Purnama

    2016-05-01

    Full Text Available Abstract - The problem is how meticulous the duties and responsibilities of the room attendant in the deluxe room Hotel Hyatt Regency Bandung, standard operational procedures in the deluxe room Hotel Hyatt Regency Bandung, and handling guest complaint in deluxe room Hotel Hyatt Regency Bandung. Author uses descriptive analysis, which is a form of writing in the actual situation describes strive about the object of research, then the data obtained in the form of a report compiled in. Based on the results of observation it can be concluded that the task and responsibility of the room attendant in the deluxe room Hyatt Regency Bandung already carry it out in accordance with standard operational procedures (SOP which is divided into two shifts, morning and evening shift which has a slightly different task, standard operational procedures in the deluxe room Hyatt Regency Bandung has been standard operating procedure in applying it at the hotel Hyatt Regency Bandung, and Guest complaint handling in deluxe room Hyatt Regency Bandung Hotel how to deal with and resolve the complaint vary slightly in view of the type of complaint. Based on the results of observation and discussion, the authors conclude that the Duty room attendant in handling customers compaint deluxe room in the Hyatt Regency Bandung Hotel when his handlers was conducted appropriately and propesional effects will be good for the image of the hyatt regency hotel bandung.   Keywords: Room Attendant, Complaint, Deluxe room   Abstraksi - Masalah yang di teliti adalah tugas dan tanggung jawab room attendant di deluxe room Hotel Hyatt Regency Bandung, standar operasional prosedur di deluxe room Hotel Hyatt Regency Bandung, dan penanganan complaint tamu di deluxe room Hotel Hyatt Regency Bandung.  Metode yang di gunakan menggunakan analisis deskriptif, yaitu bentuk penulisan yang di upayakan menggambarkan keadaan yang sebenarnya tetang objek penelitian,kemudian data yang di peroleh disusun

  5. Introduction to the feature section on functional imaging of the pelvic floor.

    Science.gov (United States)

    Maccioni, Francesca

    2013-10-01

    This is the introduction to the feature section of functional imaging of the pelvic floor, which includes 6 articles, two focused on clinical issues, while four on radiological aspects, mostly on dynamic pelvic floor MRI.

  6. Test plan for K Basin Sludge Canister and Floor Sampling Device

    International Nuclear Information System (INIS)

    Meling, T.A.

    1995-01-01

    This document provides the test plan and procedure forms for conducting the functional and operational acceptance testing of the K Basin Sludge Canister and Floor Sampling Device(s). These samplers samples sludge off the floor of the 100K Basins and out of 100K fuel storage canisters

  7. Pelvic floor exercises during and after pregnancy: a systematic review of their role in preventing pelvic floor dysfunction.

    Science.gov (United States)

    Harvey, Marie-Andrée

    2003-06-01

    To review the literature on the origin, anatomical rationale, techniques, and evidence-based effectiveness of peripartum pelvic floor exercises (PFEs) in the prevention of pelvic floor problems including urinary and anal incontinence, and prolapse. Literature was reviewed for background information. MEDLINE, EMBASE, CINAHL, and proceedings of scientific meetings were searched for evidence-based data. A comprehensive literature search was performed to find all studies that involved the use of antepartum and/or postpartum PFEs. For the MEDLINE (1966 to 2002) and CINAHL (1980 to 2002) searches, the following key words were used: urinary incontinence (prevention and control, rehabilitation, therapy), fecal incontinence, exercise or exercise therapy, Kegel, muscle contraction, muscle tonus, muscle development, pelvic floor, pregnancy, puerperium, puerperal disorders. For the EMBASE (1980 to 2002) search, the following key words were used: micturition disorder (prevention, rehab, disease management, therapy), fecal incontinence, labour complication, pregnancy disorder, puerperal disorder, antepartum care, pregnancy, kinesiotherapy, exercise, pelvic floor, bladder. A manual search was performed of available abstracts presented at the annual scientific meetings of the International Continence Society (1997, 1999 to 2002), American Urogynecologic Association (1997 to 1998, 2000 to 2002), and International Urogynecological Association (1997, 1999 to 2002). Twelve studies evaluating the role of antepartum PFE were found, of which 3 randomized controlled trials (RCTs) comparing PFEs for the prevention of urinary incontinence to controls were included. Twelve studies evaluating postpartum PFEs for prevention of urinary incontinence were reviewed, of which 4 RCTs were included. Five studies evaluating postpartum PFEs for the prevention of anal incontinence were reviewed, of which 4 RCTs were included. Participants in the studies were primiparous women. DATA TABULATION AND

  8. Quality of life in women with pelvic floor dysfunction

    OpenAIRE

    Mladenović-Segedi Ljiljana; Parezanović-Ilić Katarina; Ćurčić Aleksandar; Višnjevac Nemanja

    2011-01-01

    Background/Aim. Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfac...

  9. PELVIC FLOOR MUSCLE TRAINING IN THE TREATMENT OF URINARY INCONTINENCE AFTER RADICAL PROSTATECTOMY

    Directory of Open Access Journals (Sweden)

    Yu. L. Demidko

    2014-07-01

    Full Text Available The incidence of urinary incontinence after radical prostatectomy is 0.8 to 87%. This category of patients has pelvic floor muscle weakness and reduced perineal reflex. The treatment of these patients uses a pelvic floor exercise system that is to enhance muscle tone and to develop strong reflex contraction in response to a sudden rise in intraabdominal pressure. Pelvic floor muscle training belongs to first-line therapy for urinary incontinence occurring within 6 to 12 months after prostatectomy. The ability to control pelvic floor muscle knowingly and to train them allows one not only to increase the closing capability of sphincter mechanisms, but also to suppress involuntary detrusor contractions. We used this method in 9 patients who had undergone radical prostatectomy. The duration of pelvic floor muscle training under control was up to 25 weeks. During this period, the symptoms of incontinence were relieved. No contraindications or adverse reactions have put this method in first-line therapy for post-prostatectomy urinary incontinence.

  10. PELVIC FLOOR MUSCLE TRAINING IN THE TREATMENT OF URINARY INCONTINENCE AFTER RADICAL PROSTATECTOMY

    Directory of Open Access Journals (Sweden)

    Yu. L. Demidko

    2010-01-01

    Full Text Available The incidence of urinary incontinence after radical prostatectomy is 0.8 to 87%. This category of patients has pelvic floor muscle weakness and reduced perineal reflex. The treatment of these patients uses a pelvic floor exercise system that is to enhance muscle tone and to develop strong reflex contraction in response to a sudden rise in intraabdominal pressure. Pelvic floor muscle training belongs to first-line therapy for urinary incontinence occurring within 6 to 12 months after prostatectomy. The ability to control pelvic floor muscle knowingly and to train them allows one not only to increase the closing capability of sphincter mechanisms, but also to suppress involuntary detrusor contractions. We used this method in 9 patients who had undergone radical prostatectomy. The duration of pelvic floor muscle training under control was up to 25 weeks. During this period, the symptoms of incontinence were relieved. No contraindications or adverse reactions have put this method in first-line therapy for post-prostatectomy urinary incontinence.

  11. Analysis of Home Safety of the Elderly Living in City and Rural Areas

    Directory of Open Access Journals (Sweden)

    Nihal Buker

    2008-08-01

    Full Text Available BACKGROUND: Physiological changes and chronic diseases arising during aging process increase risk of accident of the elderly, especially the elderly living alone at their homes. Home accidents are the most commonly health problem in the elderly. This study was carried out to describe home safety of the elderly living in a city or rural area using a home safety checklist. MEDHODS: 512 living in Turkey (330 in city; 182 in rural area were evaluated via face-to-face interview using a home safety checklist during a period between December and March in 2007. In addition to sociodemographics, a questionnaire including home characteristics and life style of participants was applied. To describe home safety level, Home Safety Checklist was used. RESULTS: 51.8% of the participants living in a city and 42.8% living in rural area were aged 65-69 years. Of the participants living in a city, 59.4% were living with their partners (61.5% of the participants living in rural area. While 63.9% of the participants living in a city reported that they had a private room in their homes, 53.8% of the participants living in rural area reported that they had a private room in their homes. 2.1% of participants living in a city had an excellent home safety score. Percentage for participants living in rural area was 0.5. CONCLUSION: The results obtained from this study show that majority of houses of the elderly living in Turkey were unsafe and hazardous. Therefore, health providers and architects should work together to prevent home accidents. [TAF Prev Med Bull 2008; 7(4.000: 297-300

  12. Carbon and nitrogen in forest floor and mineral soil under six common European tree species

    DEFF Research Database (Denmark)

    Vesterdal, Lars; Schmidt, Inger K.; Callesen, Ingeborg

    2007-01-01

    The knowledge of tree species effects on soil C and N pools is scarce, particularly for European deciduous tree species. We studied forest floor and mineral soil carbon and nitrogen under six common European tree species in a common garden design replicated at six sites in Denmark. Three decades...... on forest floor C and N content was primarily attributed to large differences in turnover rates as indicated by fractional annual loss of forest floor C and N. The C/N ratio of foliar litterfall was a good indicator of forest floor C and N contents, fractional annual loss of forest floor C and N...

  13. 76 FR 92 - Multilayered Wood Flooring From the People's Republic of China: Postponement of Preliminary...

    Science.gov (United States)

    2011-01-03

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-570-971] Multilayered Wood Flooring... Department'') initiated an investigation of multilayered wood flooring from the People's Republic of China (``PRC''). See Multilayered Wood Flooring From the People's Republic of China: Initiation of...

  14. State-of-the-art of development of floor spectra

    International Nuclear Information System (INIS)

    Singh, M.P.

    1984-01-01

    Floor spectra are used as seismic inputs for the design and qualification of subsystems and equipment. Until very recently, the time history analyses with single acceleration time history as input were very commonly used. However, this approach has been observed to give nonunique floor spectrum curves. Thus, as alternatives several direct approaches have been developed. The approaches which are based on the random vibration principles but employ response spectra directly have more rational appeal. Several such approaches are available. Four different approaches, employing the mode displacement and mode acceleration formulations, covering the proportionally as well as nonproportionally damped structures, are presented. The mode displacement formulations are most commonly used, although the mode acceleration formulations seem to be the better alternatives, both for the proportionally and nonproportionally damped structures. The need for the development of other forms of floor response spectra such as the relative velocity and relative acceleration spectra is also identified

  15. Pelvic floor disorders in gynecological malignancies. An overlooked problem?

    Directory of Open Access Journals (Sweden)

    Oana M. Bodean

    2018-04-01

    Full Text Available Cervical, endometrial, ovarian, vulvar, and vaginal cancers affect women of a broad age spectrum. Many of these women are still sexually active when their cancer is diagnosed. Treatment options for gynecological malignancies, such as gynecological surgery, radiation, and chemotherapy, are proven risk factors for pelvic floor dysfunction. The prevalence of urinary incontinence, fecal incontinence, and sexual dysfunction before cancer treatment is still unclear. Hypotheses have been raised in the literature that these manifestations could represent early symptoms of pelvic cancers, but most remain overlooked even in cancer surviving patients. The primary focus of therapy is always cancer eradication, but as oncological and surgical treatment options become more successful, the number of cancer survivors increases. The quality of life of patients with gynecological cancers often remains an underrated subject. Pelvic floor disorders are not consistently reported by patients and are frequently overlooked by many clinicians. In this brief review we discuss the importance of pelvic floor dysfunction in patients with gynecological malignant tumors.

  16. Relationship between female pelvic floor dysfunction and sexual dysfunction: an observational study.

    Science.gov (United States)

    Bortolami, Arianna; Vanti, Carla; Banchelli, Federico; Guccione, Andrew A; Pillastrini, Paolo

    2015-05-01

    The ability to express one's sexuality and engage in sexual activity requires multisystemic coordination involving many psychological functions as well as the integrity of the nervous, hormonal, vascular, immune, and neuromuscular body structures and functions. The purpose of this study was to investigate the associations among pelvic floor function, sexual function, and demographic and clinical characteristics in a population of women initiating physical therapy evaluation and treatment for pelvic floor-related dysfunctions (urinary incontinence, pelvic organ prolapse, vulvodynia, vaginismus, and constipation). We consented and collected completed demographic data and data related to symptoms and clinical condition on 85 consecutive patients in an outpatient physical therapy clinic. Clinical and anthropometric characteristics were analyzed descriptively. Analysis of variance and linear regression analyses were used to analyze Female Sexual Function Index (FSFI) scale ratings, whereas zero-inflated beta-binomial regression was applied to the pain subscale. Main outcome measure was FSFI score, whereas the secondary outcome measure was the FSFI subscale score related to pain. Women in our sample were 38 years old on average, 33% of whom had given birth and 82% of whom had high tone pelvic floor. Being in the middle-tercile age group and exhibiting low pelvic floor tone (Beta = 6.8; 95% confidence interval [CI] = [1.4; 12.0]) were significantly associated with lower levels of sexual dysfunction. Women with low tone pelvic floor also reported lower pain (odds ratio = 4.0; 95% CI = [1.6; 9.6]), whereas younger aged and physically unsatisfied subjects were more likely not to have sexual activity in the month prior to scale measurement. In female patients with pelvic floor muscle dysfunction undergoing physical therapy and rehabilitation, sexual dysfunction appears to be significantly correlated with age and high pelvic floor muscle tone. © 2015

  17. Seismic proving test of process computer systems with a seismic floor isolation system

    International Nuclear Information System (INIS)

    Fujimoto, S.; Niwa, H.; Kondo, H.

    1995-01-01

    The authors have carried out seismic proving tests for process computer systems as a Nuclear Power Engineering Corporation (NUPEC) project sponsored by the Ministry of International Trade and Industry (MITI). This paper presents the seismic test results for evaluating functional capabilities of process computer systems with a seismic floor isolation system. The seismic floor isolation system to isolate the horizontal motion was composed of a floor frame (13 m x 13 m), ball bearing units, and spring-damper units. A series of seismic excitation tests was carried out using a large-scale shaking table of NUPEC. From the test results, the functional capabilities during large earthquakes of computer systems with a seismic floor isolation system were verified

  18. Effect of space allowance and flooring on the behavior of pregnant ewes.

    Science.gov (United States)

    Vik, S G; Øyrehagen, O; Bøe, K E

    2017-05-01

    Space allowance recommendations for pregnant ewes vary considerably. The aim of this experiment was to investigate the effect of space allowance and floor type on activity, lying position, displacements, and aggressive interactions in pregnant ewes. A 3 × 2 factorial experiment was conducted with space allowance (0.75, 1.50, and 2.25 m/ewe) and type of flooring (straw bedding and expanded metal flooring) as the main factors. A total of 48 pregnant ewes were randomly assigned to 6 groups with 8 ewes in each group. All groups were exposed to each treatment for 7 d. The ewes were video recorded for 24 h at the end of each treatment period and general activity, lying position in the pen, and social lying position were scored every 15 min. Displacements and aggressive interactions were scored continuously from 1030 to 1430 h. Mean lying time ( flooring had no significant effect on general activity. Ewes in the straw bedding treatment spent more time lying in the middle of the pen than ewes on expanded metal ( flooring. Hence, recommended space allowance for pregnant ewes should not be lower than 1.50 m/ewe.

  19. Floor surface decontaminating device for use in nuclear power plants

    International Nuclear Information System (INIS)

    Yoshida, Tomiji; Ue, Tatsuyuki; Omori, Nobuya; Okuzawa, Tsutomu.

    1987-01-01

    Purpose: To obtain a device for decontaminating the floor surfaces contaminated with radioactive materials in nuclear power plants or the likes, mechanically, automatically and effectively. Constitution: During running of the device by means of running wheels and castors, a decontaminating head is always applied with vibrations by a vibrator. In this state, wiping members are sent from a delivery roll, applied with vibrations at the decontaminating head. The members wipe off contamination products while in frictional contact with the floor surface and are then taken up to a winding roll with the contamination products deposited thereto. In this case, since the vibrations from the decontaminating head are transmitted by way of a resilient portion thereof to the wiping members, the vibrations transmitted from the wiping members to the floor surface are somewhat buffered. (Kawakami, Y.)

  20. The effect of pelvic floor physical therapy on sexual function in women complaining dyspareunia

    Directory of Open Access Journals (Sweden)

    Parvin Bastani

    2016-10-01

    Full Text Available Background: Dyspareunia is a pain that is occurs in the genital area before, during or after intercourse and is an important factor for sexual dysfunction. The aim of this study was to evaluate the effect of pelvic floor physical therapy on sexual function and muscle strength and endurance of pelvic floor (as a non-invasive therapy in women with dyspareunia. Methods: In this clinical trial study, 32 women in the age range of 20-50-year-old and sexually active with complaints of dyspareunia, before the investigation were examined in terms of genital health and strength and endurance of the pelvic floor muscles. After the confidence of mental health, patients underwent pelvic floor rehabilitation for 10 sessions during 3 months. After assessment, myofascial release techniques and progressive pelvic floor muscles exercise was performed for patients based on their primary strength. Finally, patients were compared in terms of the severity of dyspareunia, sexual performance status (by using female sexual function index questionnaire, improvement of symptoms, pelvic floor muscle strength and endurance before (first session of physiotherapy and after (after 3 months investigation. Results: In the remaining 32 patients with dyspareunia with a mean age of 38±1.24 years, desire index score 0.95 unit, arousal index score 1.01 unit, lubrication index score 0.67 unit, orgasm index score 0.71 unit, satisfaction index score 1.03 unit, pain index score was increased 1.05 unit, strength index score 2.44 unit, endurance index score 7.06 unit were increased in comparison to before the investigation that showed a significant different with P< 0.0001. Conclusion: According to obtained results, pelvic floor physical therapy had a significant effect in women with dyspareunia. So that the severity of dyspareunia, pelvic floor muscle strength and endurance had clinically significant improvement after pelvic floor physiotherapy.

  1. Postdischarge decontamination of MRSA, VRE, and Clostridium difficile isolation rooms using 2 commercially available automated ultraviolet-C-emitting devices.

    Science.gov (United States)

    Wong, Titus; Woznow, Tracey; Petrie, Mike; Murzello, Elena; Muniak, Allison; Kadora, Amin; Bryce, Elizabeth

    2016-04-01

    Two ultraviolet-C (UVC)-emitting devices were evaluated for effectiveness in reducing methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), and Clostridium difficile (CD). Six surfaces in rooms previously occupied by patients with MRSA, VRE, or CD were cultured before and after cleaning and after UVC disinfection. In a parallel laboratory study, MRSA and VRE suspended in trypticase soy broth were inoculated onto stainless steel carriers in triplicate, placed in challenging room areas, subjected to UVC, and subcultured to detect growth. Sixty-one rooms and 360 surfaces were assessed. Before cleaning, MRSA was found in 34.4%, VRE was found in 29.5%, and CD was found in 31.8% of rooms. Cleaning reduced MRSA-, VRE-, and CD-contaminated rooms to 27.9%, 29.5%, and 22.7%, respectively (not statistically significant). UVC disinfection further reduced MRSA-, VRE-, and CD-contaminated rooms to 3.3% (P = .0003), 4.9% (P = .0003), and 0% (P = .0736), respectively. Surface colony counts (excluding floors) decreased from 88.0 to 19.6 colony forming units (CFU) (P < .0001) after manual cleaning; UVC disinfection further reduced it to 1.3 CFU (P = .0013). In a multivariable model of the carrier study, the odds of detecting growth in broth suspensions after UVC disinfection were 7 times higher with 1 machine (odds ratio, 6.96; 95% confidence interval, 3.79-13.4) for a given organism, surface, and concentration. UVC devices are effective adjuncts to manual cleaning but vary in their ability to disinfect high concentrations of organisms in the presence of protein. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Comparative study on the physico-mechanical characteristics for five types of wood flooring

    Directory of Open Access Journals (Sweden)

    Gabriela CĂLĂTAN

    2014-12-01

    Full Text Available During the period 1600-1700, the first works with parquet elements at Versailles Palace were performed, but the high cost has made that the wooden floor to be an exclusivist product for a long time. Currently, in the last 30 years, the most innovations in flooring industry were aimed to improve the technological process, the easing of work, to reduce the losses of raw materials and to reduce the production costs. The experimental research conducted worldwide has shown that the wood processing technology, up to the flooring finite element, plays an important role in achieving a superior quality and durability and that the finishing systems have to be applied depending on the conditions of the area of use. This paper is a comparative study regarding the physico-mechanical characteristics for five types of wood flooring manufactured and marketed in Romania. In the experimental research, there were analyzed: the behavior of the floor assemblies under linearly distributed and concentrated loads, the thermal insulation characteristics and the slip resistance. The experimental results have shown that these characteristics are influenced by the wood species, the type of product (massive one or subjected to stratification technological processing, the thickness of lamellar flooring elements, and the chosen finishing method (varnishing, oiling.

  3. MODELING AND IMPLEMENTATION OF A DISTRIBUTED SHOP FLOOR MANAGEMENT AND CONTROL SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Adopting distributed control architecture is the important development direction for shop floor management and control system,is also the requirement of making it agile,intelligent and concurrent. Some key problems in achieving distributed control architecture are researched. An activity model of shop floor is presented as the requirement definition of the prototype system. The multi-agent based software architecture is constructed. How the core part in shop floor management and control system,production plan and scheduling is achieved. The cooperation of different agents is illustrated. Finally,the implementation of the prototype system is narrated.

  4. Mechanical decontamination techniques for floor drain systems

    International Nuclear Information System (INIS)

    Palau, G.L.

    1987-01-01

    The unprecedented nature of cleanup activities at Three Mile Island Unit 2 (TMI-2) following the 1979 accident has necessitated the development of new techniques to deal with radiation and contamination in the plant. One of these problems was decontamination of floor drain systems, which had become highly contaminated with various forms of dirt and sludge containing high levels of fission products and fuel from the damaged reactor core. The bulk of this contamination is loosely adherent to the drain pipe walls; however, significant amounts of contamination have become incorporated into pipe wall oxide and corrosion layers and embedded in microscopic pits and fissures in the pipe wall material. The need to remove this contamination was recognized early in the TMI-2 cleanup effort. A program consisting of development and laboratory testing of floor drain decontamination techniques was undertaken early in the cleanup with support from the Electric Power Research Institute (EPRI). Based on this initial research, two techniques were judged to show promise for use at TMI-2: a rotating brush hone system and a high-pressure water mole nozzle system. Actual use of these devices to clean floor drains at TMI-2 has yielded mixed decontamination results. The decontamination effectiveness that has been obtained is highly dependent on the nature of the contamination in the drain pipe and the combination of decontamination techniques used

  5. SIMON: A mobile robot for floor contamination surveys

    International Nuclear Information System (INIS)

    Dudar, E.; Teese, G.; Wagner, D.

    1991-01-01

    The Robotics Development group at the Savannah River Site is developing an autonomous robot to perform radiological surveys of potentially contaminated floors. The robot scans floors at a speed of one-inch/second and stops, sounds an alarm, and flashes lights when contamination in a certain area is detected. The contamination of interest here is primarily alpha and beta-gamma. The contamination levels are low to moderate. The robot, a Cybermotion K2A, is radio controlled, uses dead reckoning to determine vehicle position, and docks with a charging station to replenish its batteries and calibrate its position. It has an ultrasonic collision avoidance system as well as two safety bumpers that will stop the robot's motion when they are depressed. Paths for the robot are preprogrammed and the robot's motion can be monitored on a remote screen which shows a graphical map of the environment. The radiation instrument being used is an Eberline RM22A monitor. This monitor is microcomputer based with a serial I/O interface for remote operation. Up to 30 detectors may be configured with the RM22A. For our purposes, two downward-facing gas proportional detectors are used to scan floors, and one upward-facing detector is used for radiation background compensation. SIMON is interfaced with the RM22A in such a way that it scans the floor surface at one-inch/second, and if contamination is detected, the vehicle stops, alarms, and activates a voice synthesizer. Future development includes using the contamination data collected to provide a graphical contour map of a contaminated area. 3 refs

  6. Perforation of the sinus membrane during sinus floor elevation

    DEFF Research Database (Denmark)

    von Arx, Thomas; Fodich, Ivo; Bornstein, Michael M

    2014-01-01

    PURPOSE: To analyze the frequency of perforation of the sinus membrane during maxillary sinus floor elevation (SFE) and to assess possible risk factors. MATERIALS AND METHODS: Seventy-seven cases of SFE performed with a lateral window approach were evaluated retrospectively. Clinical and radiogra......PURPOSE: To analyze the frequency of perforation of the sinus membrane during maxillary sinus floor elevation (SFE) and to assess possible risk factors. MATERIALS AND METHODS: Seventy-seven cases of SFE performed with a lateral window approach were evaluated retrospectively. Clinical...

  7. Pulse on pulse: modulation and signification in Rafael Lozano-Hemmer's Pulse Room

    Directory of Open Access Journals (Sweden)

    Merete Carlson

    2012-06-01

    Full Text Available This article investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006 by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy of the visitor's beating heart to the flashing of a fragile light bulb, thereby transforming each light bulb into a register of individual life. But at the same time the flashing light bulbs together produce a chaotically flickering light environment composed by various layers of repetitive rhythms, a vibrant and pulsating “room”. Hence, the visitor in Pulse Room is invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic “rhythm of life” and instants of pure material processuality (flickering light bulbs; polyrhythmic layers. Taking our point of departure in a discussion of Gilles Deleuze's concepts of modulation and signaletic material in relation to electronic media, we examine how the complex orchestration of pulsation between signification and material modulation produces a multilayered sense of time and space that is central to the sensory experience of Pulse Room as a whole. Pulse Room is, at the very same time, a relational subject–object intimacy and an all-encompassing immersive environment modulating continuously in real space-time.

  8. 76 FR 76693 - Multilayered Wood Flooring From the People's Republic of China: Countervailing Duty Order

    Science.gov (United States)

    2011-12-08

    ..., tongue-and-groove construction or locking joints). All multilayered wood flooring is included within the... DEPARTMENT OF COMMERCE International Trade Administration [C-570-971] Multilayered Wood Flooring...''), the Department is issuing a countervailing duty (``CVD'') order on multilayered wood flooring from the...

  9. AIRBORNE ASBESTOS CONCENTRATIONS DURING BUFFING, BURNISHING, AND STRIPPING OF RESILIENT FLOOR TILE

    Science.gov (United States)

    The study was conducted to evaluate airborne asbestos concentrations during low-speed spray-buffing, ultra high-speed burnishing, and wet-stripping of asbestos-containing resilient floor tile under pre-existing and prepared levels of floor care maintenance. Low-speed spray-buffin...

  10. Tuberculosis screening among homeless persons with AIDS living in single-room-occupancy hotels.

    Science.gov (United States)

    Layton, M C; Cantwell, M F; Dorsinville, G J; Valway, S E; Onorato, I M; Frieden, T R

    1995-11-01

    Congregate facilities for homeless persons with the acquired immunodeficiency syndrome (AIDS) are often endemic for tuberculosis. We evaluated tuberculosis screening methods at single-room-occupancy hotels housing persons with AIDS. Residents were screened by cross matching the New York City Tuberculosis Registry, interviewing for tuberculosis history, skin testing, and chest radiography. Cases were classified as either previously or newly diagnosed. Among the 106 participants, 16 (15%) previously diagnosed tuberculosis cases were identified. Participants' tuberculosis histories were identified by the questionnaire (100%) or by registry match (69%). Eight participants (50%) were noncompliant with therapy. These findings prompted the establishment of a directly observed therapy program on site.

  11. Active charge, passive discharge floor space heating system

    Energy Technology Data Exchange (ETDEWEB)

    Salt, H.; Mahoney, K.J.

    1987-01-01

    This space heating system has a rockbed beneath and in contact with the floor of a dwelling, which is heated by radiation and convection from the floor. The ability of the heating system to maintain comfort conditions with no additional energy input is discussed and it is shown that the system is more suitable for use in mild climates than severe ones. Experimental work on horizontal air flow rockbeds is reported and shows that shallow beds can be designed in the same way as vertical air flow beds. The influence of natural convection on the effective thermal conductivity of the experimental rockbeds is reported.

  12. Carbon dioxide flux measurements from a coastal Douglas-fir forest floor

    International Nuclear Information System (INIS)

    Drewitt, G.B.

    2002-01-01

    This thesis examined the process that affects the exchange of carbon between the soil and the atmosphere with particular attention to the large amounts of carbon stored in soils in the form of decaying organic matter. This forest floor measuring study was conducted in 2000 at a micro-meteorological tower flux site in a coastal temperature Douglas-fir forest. The measuring study involved half hourly measurements of both carbon dioxide and below-ground carbon dioxide storage. Measurements were taken at 6 locations between April and December to include a large portion of the growing season. Eddy covariance (EC) measurements of carbon dioxide flux above the forest floor over a two month period in the summer and the autumn were compared with forest floor measurements. Below-ground carbon dioxide mixing ratios of soil air were measured at 6 depths between 0.02 to 1 m using gas diffusion probes and a syringe sampling method. Maximum carbon dioxide fluxes measured by the soil chambers varied by a factor of 3 and a high spatial variability in soil carbon dioxide flux was noted. Forest floor carbon dioxide fluxes measured by each of the chambers indicated different sensitivities to soil temperature. Hysteresis in the flux temperature relationship over the year was evident. Reliable below-canopy EC measurements of the forest floor carbon dioxide flux were difficult to obtain because of the every low wind speeds below the forest canopy. The amount of carbon dioxde present in the soil increased rapidly with depth near the surface but less rapidly deeper in the soil. It was suggested that approximately half of the carbon dioxide produced below-ground comes from between the soil surface and the first 0.15 m of depth. Carbon dioxide fluxes from the floor of a Douglas-fir forest were found to be large compared to other, less productive ecosystems

  13. Impact of vaginal parity and aging on the architectural design of pelvic floor muscles.

    Science.gov (United States)

    Alperin, Marianna; Cook, Mark; Tuttle, Lori J; Esparza, Mary C; Lieber, Richard L

    2016-09-01

    Vaginal delivery and aging are key risk factors for pelvic floor muscle dysfunction, which is a critical component of pelvic floor disorders. However, alterations in the pelvic floor muscle intrinsic structure that lead to muscle dysfunction because of childbirth and aging remain elusive. The purpose of this study was to determine the impact of vaginal deliveries and aging on human cadaveric pelvic floor muscle architecture, which is the strongest predictor of active muscle function. Coccygeus, iliococcygeus, and pubovisceralis were obtained from younger donors who were ≤51 years old, vaginally nulliparous (n = 5) and vaginally parous (n = 6) and older donors who were >51 years old, vaginally nulliparous (n = 6) and vaginally parous (n = 6), all of whom had no history of pelvic floor disorders. Architectural parameters, which are predictive of muscle's excursion and force-generating capacity, were determined with the use of validated methods. Intramuscular collagen content was quantified by hydroxyproline assay. Main effects of parity and aging and the interactions were determined with the use of 2-way analysis of variance, with Tukey's post-hoc testing and a significance level of .05. The mean age of younger and older donors differed by approximately 40 years (P = .001) but was similar between nulliparous and parous donors within each age group (P > .9). The median parity was 2 (range, 1-3) in younger and older vaginally parous groups (P = .7). The main impact of parity was increased fiber length in the more proximal coccygeus (P = .03) and iliococcygeus (P = .04). Aging changes manifested as decreased physiologic cross-sectional area across all pelvic floor muscles (P < .05), which substantially exceeded the age-related decline in muscle mass. The physiologic cross-sectional area was lower in younger vaginally parous, compared with younger vaginally nulliparous, pelvic floor muscles; however, the differences did not reach statistical significance

  14. Magnetic Resonance Imaging (MRI): Dynamic Pelvic Floor

    Science.gov (United States)

    ... to a CD or uploaded to a digital cloud server. Dynamic pelvic floor MRI provides detailed pictures ... with you. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  15. One-floor building as elasto-plastic oscillator subject to and interacting with Gaussian base motion

    DEFF Research Database (Denmark)

    Randrup-Thomsen, Søren; Ditlevsen, Ove Dalager

    1997-01-01

    vibration of the (n-1)th floor. Moreover the model simulates the soil-structure interaction through the exchange of energy between the top floor and the elastic structure below the top floor. The obtained distribution approximations are checked by comparison with direct simulation results using...

  16. Divergent axial morphogenesis and early shh expression in vertebrate prospective floor plate

    Directory of Open Access Journals (Sweden)

    Stanislav Kremnyov

    2018-01-01

    Full Text Available Abstract Background The notochord has organizer properties and is required for floor plate induction and dorsoventral patterning of the neural tube. This activity has been attributed to sonic hedgehog (shh signaling, which originates in the notochord, forms a gradient, and autoinduces shh expression in the floor plate. However, reported data are inconsistent and the spatiotemporal development of the relevant shh expression domains has not been studied in detail. We therefore studied the expression dynamics of shh in rabbit, chicken and Xenopus laevis embryos (as well as indian hedgehog and desert hedgehog as possible alternative functional candidates in the chicken. Results Our analysis reveals a markedly divergent pattern within these vertebrates: whereas in the rabbit shh is first expressed in the notochord and its floor plate domain is then induced during subsequent somitogenesis stages, in the chick embryo shh is expressed in the prospective neuroectoderm prior to the notochord formation and, interestingly, prior to mesoderm immigration. Neither indian hedgehog nor desert hedgehog are expressed in these midline structures although mRNA of both genes was detected in other structures of the early chick embryo. In X. laevis, shh is expressed at the beginning of gastrulation in a distinct area dorsal to the dorsal blastopore lip and adjacent to the prospective neuroectoderm, whereas the floor plate expresses shh at the end of gastrulation. Conclusions While shh expression patterns in rabbit and X. laevis embryos are roughly compatible with the classical view of “ventral to dorsal induction” of the floor plate, the early shh expression in the chick floor plate challenges this model. Intriguingly, this alternative sequence of domain induction is related to the asymmetrical morphogenesis of the primitive node and other axial organs in the chick. Our results indicate that the floor plate in X. laevis and chick embryos may be initially

  17. Improving operating room safety

    Directory of Open Access Journals (Sweden)

    Garrett Jill

    2009-11-01

    Full Text Available Abstract Despite the introduction of the Universal Protocol, patient safety in surgery remains a daily challenge in the operating room. This present study describes one community health system's efforts to improve operating room safety through human factors training and ultimately the development of a surgical checklist. Using a combination of formal training, local studies documenting operating room safety issues and peer to peer mentoring we were able to substantially change the culture of our operating room. Our efforts have prepared us for successfully implementing a standardized checklist to improve operating room safety throughout our entire system. Based on these findings we recommend a multimodal approach to improving operating room safety.

  18. Prefabricated floor panels composed of fiber reinforced concrete and a steel substructure

    DEFF Research Database (Denmark)

    Lárusson, Lárus H.; Fischer, Gregor; Jönsson, Jeppe

    2013-01-01

    This paper reports on a study on prefabricated composite and modular floor deck panels composed of relatively thin fiber reinforced concrete slabs connected to steel substructures. The study focuses on the design, manufacturing, structural improvements and behavior of the floor systems during...

  19. Comparison of slime-producing coagulase-negative Staphylococcus colonization rates on vinyl and ceramic tile flooring materials.

    Science.gov (United States)

    Yazgi, H; Uyanik, M H; Ayyildiz, A

    2009-01-01

    This study investigated the colonization of slime-producing coagulase-negative Staphylococcus (CoNS) in 80 patient wards in Turkey (40 vinyl and 40 ceramic tile floors). A total of 480 samples that included 557 CoNS isolates were obtained. Slime production was investigated with the Christensen method and methicillin-susceptibility was tested by the disk-diffusion method. There was a significant difference in the percentage of slime-producing CoNS isolates on vinyl (12.4%) versus ceramic tile flooring (4.4%). From vinyl flooring, the percentage of slime producing methicillin-resistant CoNS (MRCoNS) (8.9%) was significantly higher than for methicillin-sensitive CoNS (MSCoNS) (3.6%), whereas there was no difference from ceramic tile flooring (2.5% MRCoNS versus 1.8% MSCoNS). The most commonly isolated slime-producing CoNS species was S. epidermidis on both types of flooring. It is concluded that vinyl flooring seems to be a more suitable colonization surface for slime-producing CoNS than ceramic tile floors. Further studies are needed to investigate bacterial strains colonized on flooring materials, which are potential pathogens for nosocomial infections.

  20. The Design of a Semi-Prefabricated LVL-Concrete Composite Floor

    Directory of Open Access Journals (Sweden)

    David Yeoh

    2012-01-01

    Full Text Available This paper describes the design of a novel semi-prefabricated LVL-concrete composite floor that has been developed in New Zealand. In this solution, the floor units made from LVL joists and plywood are prefabricated in the factory and transported to the building site. The units are then lifted onto the supports and connected to the main frames of the building and to the adjacent units. Finally, a concrete topping is poured on top of the units in order to form a continuous slab connecting all the units. Rectangular notches cut from the LVL joists and reinforced with coach screws provide the composite action between the concrete slab and the LVL joists. This system proved to be an effective modular solution that ensures rapid construction. A design procedure based on the use of the effective flexural stiffness method, also known as the “gamma method” is proposed for the design of the composite floor at ultimate and serviceability limit states, in the short and long term. By comparison with the experimental results, it is shown that the proposed method leads to conservative design. A step-by-step design worked example of this novel semi-prefabricated composite floor concludes the paper.

  1. Reliability of estimating the room volume from a single room impulse response

    OpenAIRE

    Kuster, M.

    2008-01-01

    The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and acoustic characteristics. The limitations in identifying the pivotal specular reflections of the geometrical acoustics model in measured room impulse responses are examined both theoretically and expe...

  2. Morphological changes after pelvic floor muscle training measured by 3-dimensional ultrasonography: a randomized controlled trial.

    Science.gov (United States)

    Braekken, Ingeborg Hoff; Hoff Braekken, Ingeborg; Majida, Memona; Engh, Marie Ellström; Bø, Kari

    2010-02-01

    To investigate morphological and functional changes after pelvic floor muscle training in women with pelvic organ prolapse. This randomized controlled trial was conducted at a university hospital and a physical therapy clinic. One hundred nine women with pelvic organ prolapse stages I, II, and III were randomly allocated by a computer-generated random number system to pelvic floor muscle training (n=59) or control (n=50). Both groups received lifestyle advice and learned to contract the pelvic floor muscles before and during increases in intraabdominal pressure. In addition the pelvic floor muscle training group did individual strength training with a physical therapist and daily home exercise for 6 months. Primary outcome measures were pelvic floor muscle (pubovisceral muscle) thickness, levator hiatus area, pubovisceral muscle length at rest and Valsalva, and resting position of bladder and rectum, measured by three-dimensional ultrasonography. Seventy-nine percent of women in the pelvic floor muscle training group adhered to at least 80% of the training protocol. Compared with women in the control group, women in the pelvic floor muscle training group increased muscle thickness (difference between groups: 1.9 mm, 95% confidence interval [CI] 1.1-2.7, Ppelvic floor muscle stiffness. Supervised pelvic floor muscle training can increase muscle volume, close the levator hiatus, shorten muscle length, and elevate the resting position of the bladder and rectum. www.clinicaltrials.gov, NCT00271297. I.

  3. Sand Floor for Farmed Blue Foxes: Effects on Claws, Adrenal Cortex Function, Growth and Fur Properties

    Directory of Open Access Journals (Sweden)

    Leena Ahola

    2009-01-01

    Full Text Available Farmed blue foxes (Vulpes lagopus are traditionally housed on mesh floors where they are unable to perform certain species-specific behaviours, such as digging, which may compromise the animals' welfare. This study describes how a possibility to use in-cage sand floor affects welfare-related variables like growth of the claws, adrenal cortex function, and fur properties in juvenile blue foxes. The foxes (N=32 were housed in male-female sibling pairs in an outdoor fur animal shed in cage systems consisting of two traditional fox cages. For the eight male-female sibling pairs of the Control group, there was a mesh floor in both cages of each cage system, whereas for the eight pairs of the Sand group there was a mesh floor in one cage and a 30–40 cm deep earth floor in the other cage. The results show that sand floor is beneficial for the wearing of the claws of foxes. Furthermore, an early experience of sand floor may have positive effects on the foxes' fur development. The results, however, also suggest that there might appear welfare problems observed as disturbed claw growth and increased adrenal cortex activation if foxes that are once provided with clean and unfrozen sand floor are not allowed to enjoy this floor all the time.

  4. Pelvic floor electrophysiology patterns associated with faecal ...

    African Journals Online (AJOL)

    Hussein Al-Moghazy Sultan

    2012-12-28

    Dec 28, 2012 ... pelvic floor electrophysiological abnormalities associated with. FI were illustrated in ... detection of a localized anal sphincter defect clinically and ..... Woods R, Voyvodic F, Schloithe A, Sage M, Wattchow D. Anal sphincter ...

  5. Applicability of the Environmental Relative Moldiness Index for Quantification of Residential Mold Contamination in an Air Pollution Health Effects Study

    Directory of Open Access Journals (Sweden)

    Ali Kamal

    2014-01-01

    Full Text Available The Near-Road Exposures and Effects of Urban Air Pollutants Study (NEXUS investigated the impact of exposure to traffic-related air pollution on the respiratory health of asthmatic children in Detroit, Michigan. Since indoor mold exposure may also contribute to asthma, floor dust samples were collected in participants homes (n=112 to assess mold contamination using the Environmental Relative Moldiness Index (ERMI. The repeatability of the ERMI over time, as well as ERMI differences between rooms and dust collection methods, was evaluated for insights into the application of the ERMI metric. ERMI values for the standard settled floor dust samples had a mean ± standard deviation of 14.5±7.9, indicating high levels of mold contamination. ERMI values for samples collected from the same home 1 to 7 months apart (n=52 were consistent and without systematic bias. ERMI values for separate bedroom and living room samples were highly correlated (r=0.69, n=66. Vacuum bag dust ERMI values were lower than for floor dust but correlated (r=0.58, n=28. These results support the use of the ERMI to evaluate residential mold exposure as a confounder in air pollution health effects studies.

  6. Developing a System Architecture for Holonic Shop Floor Control

    DEFF Research Database (Denmark)

    Sørensen, Christian; Langer, Gilad; Alting, Leo

    1998-01-01

    This paper describes the results of research regarding the emerging theory of Holonic Manufacturing Systems. This theory and in particular its corresponding reference architecture serves as the basis for the development of a system-architecture for shop floor control systems in a multi-cellular c......This paper describes the results of research regarding the emerging theory of Holonic Manufacturing Systems. This theory and in particular its corresponding reference architecture serves as the basis for the development of a system-architecture for shop floor control systems in a multi...

  7. Assessment of a semiautomated pelvic floor measurement model for evaluating pelvic organ prolapse on MRI.

    Science.gov (United States)

    Onal, S; Lai-Yuen, S; Bao, P; Weitzenfeld, A; Greene, K; Kedar, R; Hart, S

    2014-06-01

    The objective of this study was to assess the performance of a semiautomated pelvic floor measurement algorithmic model on dynamic magnetic resonance imaging (MRI) images compared with manual pelvic floor measurements for pelvic organ prolapse (POP) evaluation. We examined 15 MRIs along the midsagittal view. Five reference points used for pelvic floor measurements were identified both manually and using our semiautomated measurement model. The two processes were compared in terms of accuracy and precision. The semiautomated pelvic floor measurement model provided highly consistent and accurate locations for all reference points on MRI. Results also showed that the model can identify the reference points faster than the manual-point identification process. The semiautomated pelvic floor measurement model can be used to facilitate and improve the process of pelvic floor measurements on MRI. This will enable high throughput analysis of MRI data to improve the correlation analysis with clinical outcomes and potentially improve POP assessment.

  8. Muscle function of the pelvic floor in healthy, puerperal women with pelvic floor dysfunction.

    Science.gov (United States)

    Castro-Pardiñas, M A; Torres-Lacomba, M; Navarro-Brazález, B

    2017-05-01

    To understand the function of the pelvic floor muscles (PFM) at different ages in healthy women and in puerperal women with pelvic floor dysfunctions (PFD) and to ascertain whether there are differences among them. A descriptive cross-sectional study was conducted between June 2014 and September 2016 and included 177 women, 70 of whom had no symptoms of PFD, 53 primiparous mothers in late postpartum and 54 with PFD. The function of the PFM was measured through vaginal palpation (quality of the contraction); manometry (force); dynamometer (tone, strength, and response to stretching), and surface electromyography (neuromuscular activity and resistance). The healthy women showed superior values for PFM tone, maximum strength, neuromuscular activity and resistance than the puerperal mothers and the women with PFD (P.05). The muscle function of the healthy women did not vary significantly with age, except in the case of tone, which was lower in the women older than 46 years (P=.004). Age and births decrease the baseline tone of the PFM in healthy women. Therefore, lower strength, resistance and neuromuscular activity appear to be the main difference between the PFM of women with PFD and the PFM of healthy women. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. PCB-containing wood floor finish is a likely source of elevated PCBs in residents' blood, household air and dust: a case study of exposure

    Directory of Open Access Journals (Sweden)

    Seryak Liesel M

    2008-01-01

    Full Text Available Abstract Background Polychlorinated biphenyls (PCBs are persistent pollutants identified worldwide as human blood and breast milk contaminants. Because they bioaccumulate, consumption of meat, fish, and dairy products predicts human blood concentrations. PCBs were also used widely in building materials, including caulks and paints, but few studies have evaluated the contribution of these exposures to body burden. Methods In an earlier study, we detected PCBs in indoor air in 31% of 120 homes on Cape Cod, MA. Two of the homes had much higher concentrations than the rest, so we retested to verify the initial finding, evaluate blood PCB concentrations of residents, and identify the PCB source. Results Air and dust concentrations remained elevated over 5 years between initial and follow-up sampling. Blood serum concentrations of PCBs in residents of the homes were generally elevated above the 95th percentile of a representative sample of the US population. Serum concentrations in residents and air and dust concentrations were especially high in a home where a resident reported use of PCB-containing floor finish in the past, and where the floor of one room was sanded and refinished just prior to sample collection. Conclusion This case-study suggests that PCB residues in homes may be more significant contributors to overall exposure than diet for some people, and that use of a commercially-available PCB-containing wood floor finish in residences during the 1950s and 1960s is an overlooked but potentially important source of current PCB exposure in the general population.

  10. STATISTICAL ANALYSIS OF TANK 18F FLOOR SAMPLE RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Harris, S.

    2010-09-02

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 18F as per the statistical sampling plan developed by Shine [1]. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL [2]. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results [3] to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL{sub 95%}) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 18F. The uncertainty is quantified in this report by an upper 95% confidence limit (UCL{sub 95%}) on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL{sub 95%} was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  11. Antibacterial efficacy of commercial disinfectants on dirt floor used in poultry breeder houses

    Directory of Open Access Journals (Sweden)

    F Pilotto

    2007-06-01

    Full Text Available Dirt floors are used on most Brazilian poultry farms since the construction of concrete floors is very expensive. In vitro tests carried out to verify the effectiveness of disinfectants do not consider the adverse conditions found in poultry farms. Therefore, the present study aimed at evaluating the effect of six commercial disinfectants on the reduction of total and fecal coliforms on the dirt floor of breeder houses. The amount of disinfectant solution to be used per square meter was defined by counting total and fecal coliforms at different soil depths and by analyzing soil physical properties. Coliforms were detected at 0.5 cm, and one liter of disinfectant solution was sufficient for soil saturation at this depth. After that, the efficacy of six commercial products (caustic soda, hydrated lime, phenols 1 and 2, iodine, glutaraldehyde, and quaternary ammonium in reducing the number of coliforms, after six hours of contact with the dirt floor, was assessed using the most probable number (MPN method. Escherichia coli specimens isolated from the dirt floor were used to evaluate in vitro effectiveness of disinfectants. Products that yielded the best results in the MPN method were also effective in the in vitro tests. Among the tested disinfectants, hydrated lime was the most efficient, reducing the initial contamination by 2.9 log after six hours of contact with the dirt floor.

  12. Dynamic magnetic resonance imaging for assessment of minimally invasive pelvic floor reconstruction with polypropylene implant

    International Nuclear Information System (INIS)

    Siegmann, Katja C.; Reisenauer, Christl; Speck, Sina; Barth, Sonja; Kraemer, Bernhard; Claussen, Claus D.

    2011-01-01

    Introduction: The purpose of the study was to assess the usefulness of dynamic MRI in patients with pelvic organ prolapse after pelvic floor repair with polypropylene mesh. Materials and methods: Fifteen consecutive patients (mean age 66.5 years) who were scheduled for either anterior (n = 9) or posterior (n = 6) pelvic floor repair were prospectively evaluated by clinical assessment and dynamic MRI 1 day before and 3 months after surgery. MRI diagnoses and MRI measurements of relevant anatomical points at rest and on straining were analysed before and after surgery. Results: At follow-up assessment 93.3% of all patients were clinically cured. Dynamic MRI showed newly developed (n = 6) or increased (n = 6) pelvic organ prolapse in 80% (n = 12) of all patients 3 months after pelvic floor repair. Most of them (n = 11; 91.7%) affected the untreated pelvic floor compartment. On straining anatomical points of reference in the anterior pelvic floor compartment were significantly (p < 0.05) elevated after anterior repair and rectal bulging was significantly (p = 0.036) reduced after posterior pelvic floor repair. Conclusions: In this study dynamic MRI could verify the effective support of anterior and posterior pelvic floor structures by anterior and posterior polypropylene implant respectively. But dynamic MRI demonstrates if one compartment of the pelvic floor is repaired another compartment frequently (73.3%) develops dysfunction. These results did not correspond to clinical symptoms on short-term follow-up (3 months). Studies with long-term follow-up are necessary to prove if dynamic MRI can reliably identify clinically significant pelvic organ prolapse after pelvic floor repair before the onset of symptoms.

  13. Seeing Results in Flooring for Schools

    Science.gov (United States)

    Simmons, Brian

    2011-01-01

    Operations staffs at education facilities of all sizes are tasked with selecting a hard floor cleaning program that is cost-effective, efficient and highly productive. With an increased focus on the sustainability of an environment, facility managers also must select a program that meets sustainability goals while maintaining a healthful, safe…

  14. Urinary incontinence, pelvic floor dysfunction, exercise and sport.

    Science.gov (United States)

    Bø, Kari

    2004-01-01

    Urinary incontinence is defined as "the complaint of any involuntary leakage of urine" and is a common problem in the female population with prevalence rates varying between 10% and 55% in 15- to 64-year-old women. The most frequent form of urinary incontinence in women is stress urinary incontinence, defined as "involuntary leakage on effort or exertion, or on sneezing or coughing". The aim of this article is to systematically review the literature on urinary incontinence and participation in sport and fitness activities with a special emphasis on prevalence and treatment in female elite athletes. Stress urinary incontinence is a barrier to women's participation in sport and fitness activities and, therefore, it may be a threat to women's health, self-esteem and well-being. The prevalence during sports among young, nulliparous elite athletes varies between 0% (golf) and 80% (trampolinists). The highest prevalence is found in sports involving high impact activities such as gymnastics, track and field, and some ball games. A 'stiff' and strong pelvic floor positioned at an optimal level inside the pelvis may be a crucial factor in counteracting the increases in abdominal pressure occurring during high-impact activities. There are no randomised controlled trials or reports on the effect of any treatment for stress urinary incontinence in female elite athletes. However, strength training of the pelvic floor muscles has been shown to be effective in treating stress urinary incontinence in parous females in the general population. In randomised controlled trials, reported cure rates, defined as athletes than in other women. There is a need for more basic research on pelvic floor muscle function during physical activity and the effect of pelvic floor muscle training in female elite athletes.

  15. Symptomatic knee disorders in floor layers and graphic designers. A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Jensen Lilli

    2012-09-01

    Full Text Available Abstract Background Previous studies have described an increased risk of developing tibio-femoral osteoarthritis (TF OA, meniscal tears and bursitis among those with a trade as floor layers. The purpose of this study was to analyse symptomatic knee disorders among floor layers that were highly exposed to kneeling work tasks compared to graphic designers without knee-demanding work tasks. Methods Data on the Knee injury and Osteoarthritis Outcome Score (KOOS were collected by questionnaires. In total 134 floor layers and 120 graphic designers had a bilateral radiographic knee examination to detect TF OA and patella-femoral (PF OA. A random sample of 92 floor layers and 49 graphic designers had Magnetic Resonance Imaging (MRI of both knees to examine meniscal tears. Means of the subscales of KOOS were compared by analysis of variance. The risk ratio of symptomatic knee disorders defined as a combination of radiological detected knee OA or MRI-detected meniscal tears combined with a low KOOS score was estimated by logistic regression in floor layers with 95% confidence interval (CI and adjusted for age, body mass index, traumas, and knee-straining sports activities. Symptomatic knee OA or meniscal tears were defined as a combination of low KOOS-scores and radiographic or MRI pathology. Results Symptomatic TF and medial meniscal tears were found in floor layers compared to graphic designers with odds ratios 2.6 (95%CI 0.99-6.9 and 2.04 (95% CI 0.77-5.5, respectively. There were no differences in PF OA. Floor layers scored significantly lower on all KOOS subscales compared to graphic designers. Significantly lower scores on the KOOS subscales were also found for radiographic TF and PF OA regardless of trade but not for meniscal tears. Conclusions The study showed an overall increased risk of developing symptomatic TF OA in a group of floor layers with a substantial amount of kneeling work positions. Prevention would be appropriate to reduce the

  16. Study on in-service inspection methods for the above-ground oil tanks floors

    Energy Technology Data Exchange (ETDEWEB)

    Min Xiong; Yewei Kang; Mingchun, Lin; Yi Sun [PetroChina Pipeline R and D Center, Langfang (China)

    2009-07-01

    It is very dangerous to the environment when oil tank floors get corrosion or leak during its long-time service. The traditional inspection methods need to shut down a tank and to empty it, then to clean it in order to inspect the floor. Comparing with the traditional methods, the in-service methods can inspect tank floors rapidly without removing product and opening the tank and can save many costs of tank emptying and cleaning. This paper explores three up-to date in-service inspection methods for the oil tank floors which are acoustic emission technology ultrasonic guided wave technology and mobile robot technology. The theoretic foundation and application status of each method is described. The advantage and disadvantage of each in-service detection technology is concluded. At last some proposals are made. (author)

  17. Economic Analysis Of Radiation Surface Coating Of Parquet Flooring

    International Nuclear Information System (INIS)

    Danu, S.

    1989-01-01

    The surface coating of mosaic parquet flooring has been done using electron beam and UV irradiation in a pilot scale and technically successful. Economic analysis of the coating process will be discussed in this paper. Four kinds of irradiated parquet flooring were used for comparing costs and important factors on the analysis such as capital, production cost, selling price, break-event point, payout time and internal rate of return. The results showed there the higher quality of the products, the higher are its production cost and selling price. The selling price of irradiated parquet flooring per m2 for process A, B, C and D were Rp. 20,700; Rp. 23,900; Rp. 24,500; and Rp. 25,000 at the lowest profit level of 10% and RP. 25,500; Rp. 34,700; Rp. 35,500; and Rp. 36,400 at the highest profit level of 150% of the fixed capital. The total capital required were Rp. 1.9 billion up to 3.3 billion. (author). 5 refs, 9 tabs

  18. Using Masculine Capital to Understand the Role of a Sport Program in the Lives of Men From a Western Canadian Inner City.

    Science.gov (United States)

    Holt, Nicholas L; Scherer, Jay; Koch, Jordan

    2015-10-01

    The purpose of this study was to examine the role of a sport program in the lives of homeless men with severe mental illnesses and addictions. Interviews were conducted with eight men who attended a floor hockey program, and data examined using categorical-content narrative methodology. Five themes captured the role of the floor hockey program in the men's lives: (a) relationships with program leader, (b) therapy, (c) community, (d) action, and (e) achievement. These themes were interpreted using theories of masculinity (Connell, 1995; Gough, 2014). Relationships with the program leader and other men, and ways in which they were allowed to play with physicality, provided opportunities to accumulate masculine capital (i.e., ways in which competence in traditionally masculine behaviors provides masculine credit). Practically, the findings suggest that sport program delivery for men such as those in this study can be enhanced by providing opportunities for accruing masculine capital.

  19. Evaluation of pelvic floor anatomy with MR imaging

    International Nuclear Information System (INIS)

    Sato, Y.; Pringle, K.C.; Bergman, R.A.; Yuh, W.T.C.; Smith, W.C.; Franken, E.A. Jr.; Schreiber, A.E.

    1987-01-01

    MR imaging allows direct diagnostic imaging of the anorectal sphincter. This report reviews the normal anatomy of the musculature of the pelvic floor as demonstrated by MR imaging with emphasis on its relationship to the rectum and anal canal correlating with cadaver dissection. Anatomic landmarks routinely depicted by MR imaging include the levator ani, striated muscle complex, superficial transverse perineal muscle, and the urogenital diaphragm. The following abnormalities of the sphincteric musculature were also studied: hindgut duplication, hypoplasia, both abnormal and normal placement of the rectum after surgical procedures for anorectal anomalies, rectal inflammation, and displacement of the musculature by mass lesions. MR imaging plays an important role for the preoperative and postoperative evaluation of pelvic floor pathology

  20. Seismic analysis and design of steel beam - thick slab floor systems

    International Nuclear Information System (INIS)

    Reed, P.W.

    1981-01-01

    This paper presents a method for seismic analysis and design of floor systems composed of thick reinforced concrete slabs supported by steel beams. The response spectrum modal analysis is used to determine the dynamic response of an orthotropic finite element model. An approximate approach to find the fundamental frequency is explained, allowing an actual acceleration to be determined. The fundamental mode is found to be a major portion of the overall response, whereas the secondary modes are shown to result in a very small portion of the overall response. Dynamic multipliers for the fundamental mode and significant secondary modes are given for several typical floor layouts. These would be used to find equivalent static stress resultants which are used to design the floor. (orig.)