WorldWideScience

Sample records for light source synchrontron

  1. Advanced Light Source (ALS)

    Data.gov (United States)

    Federal Laboratory Consortium — The Advanced Light Source (ALS), a world leader in soft x-ray science, generates light in the wavelengths needed for examining the atomic and electronic structure of...

  2. Light Sources and Lighting Circuits

    Science.gov (United States)

    Honda, Hisashi; Suwa, Takumi; Yasuda, Takeo; Ohtani, Yoshihiko; Maehara, Akiyoshi; Okada, Atsunori; Komatsu, Naoki; Mannami, Tomoaki

    According to the Machinery Statistics of the Ministry of Economy, Trade and Industry, the production of incandescent lamps in Japan in 2007 was 990 million units (90.0% of the previous year's total), in which the production of incandescent lamps for general lighting was 110 million units (90.0% of the previous year's total) and of tungsten-halogen lamps was 44 million units (96.6% of the previous year's total). The production of fluorescent lamps was 927 million units (93.9% of the previous year's total), in which general fluorescent lamps, excluding those for LCD back lighting, was 320 million units (87.2% of the previous year's total). Also, the production of HID lamps was 10 million units (101.5% of the previous year's total). On the other hand, when the numbers of sales are compared with the sales of the previous year, incandescent lamps for general use was 99.8%, tungsten-halogen lamps was 96.9%, fluorescent lamps was 95.9%, and HID lamps was 98.9%. Self-ballasted fluorescent lamps alone showed an increase in sales as strong as 29 million units, or 121.7% of the previous year's sales. It is considered that the switchover of incandescent lamps to HID lamps was promoted for energy conservation and carbon dioxide reduction with the problem of global warming in the background. In regard to exhibitions, Lighting Fair 2007 was held in Tokyo in March, and LIGHTFAIR INTERNATIONAL 2007 was held in New York in May. Regarding academic conferences, LS:11 (the 11th International Symposium on the Science & Technology of Light Sources) was held in Shanghai in May, and the First International Conference on White LEDs and Solid State Lighting was held in Tokyo in November. Both conferences suggested that there are strong needs and concerns now about energy conservation, saving natural resources, and restrictions of hazardous materials. In regard to incandescent lamps, the development of products aiming at higher efficacy, electric power savings, and longer life was advanced by

  3. Fifth generation light sources

    Science.gov (United States)

    Romaniuk, Ryszard S.

    2016-12-01

    Coherent light sources are one of the most fundamental research tools in biology, technology and in other areas. Synchrotron light source consists of a few basic parts: energy source - which is an electron beam accelerator, energy converter between electron and photon beams - which is an undulator, and photon user experimental lines. Each of these parts is separately a complex system, which is currently a subject to fast technological development. Future light sources of the fifth generation are based on completely new solutions of these fundamental parts, in comparison with the sources of the previous generations. Energy source is a new generation laser - plasma accelerator with electrical field in the area of multiple GV/m. A miniature undulator is tested in the MEMS technology from new materials. Classical light beam lines, vacuum, and difficult for management and beam distribution, change their meaning in the case of availability of miniature undulators positioned immediately at or even inside the experimental stations. After an introduction concerning the light sources of the previous generations, the article shows current research efforts on the mentioned key components of the fifth generation light sources. In some cases this is a continuation and modernization of the previous technologies, in the majority it is a brave endeavour to apply completely new technologies, like laser - plasma acceleration.

  4. Thermoelectricity Light Sources

    Institute of Scientific and Technical Information of China (English)

    SHIYongji

    1997-01-01

    A thermoelectricity light source in a gaseous plasma discharge between two electrodes is described,one of which emits electrons thermoionically.The analytical model describing basic physical phenomena is developed.The results are excellent agreement with simulated test.

  5. Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Sah, R.C.

    1983-03-01

    The Advanced Light Source (ALS) is a new synchrotron radiation source which has been proposed by Lawrence Berkeley Laboratory. The ALS will be a key component in a major new research facility, the National Center for Advanced Materials. The ALS will consist of an electron linear accelerator, a booster synchrotron, a 1.3-GeV electron storage ring, and a number of photon beam lines. Most or all photon beam lines will originate from wiggler and undulator magnets placed in the 12 long straight sections of the ALS. A very low electron beam emittance will provide photon beams of unsurpassed spectral brilliance from specially-designed undulators, and a high radiofrequency will produce very short pulse lengths.

  6. Nitride quantum light sources

    Science.gov (United States)

    Zhu, T.; Oliver, R. A.

    2016-02-01

    Prototype nitride quantum light sources, particularly single-photon emitters, have been successfully demonstrated, despite the challenges inherent in this complex materials system. The large band offsets available between different nitride alloys have allowed device operation at easily accessible temperatures. A wide range of approaches has been explored: not only self-assembled quantum dot growth but also lithographic methods for site-controlled nanostructure formation. All these approaches face common challenges, particularly strong background signals which contaminate the single-photon stream and excessive spectral diffusion of the quantum dot emission wavelength. If these challenges can be successfully overcome, then ongoing rapid progress in the conventional III-V semiconductors provides a roadmap for future progress in the nitrides.

  7. Swiss Light Source SLS

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-09-01

    The Paul Scherrer Institute has begun work on the implementation of the Swiss Synchrotron Light Source (SLS). The construction of this facility, which will have international scope, is intended to provide a national focus for co-operation between various disciplines and for research in material sciences. Although basic research in physics and chemistry, biology, medicine and environmental sciences would seem to be in the foreground, industrial users also have an interest in the SLS. At present, this mainly centres on investigations into the structure of biological and chemical molecules, the use of high-performance methods of analysis, and the manufacture and investigation of microstructures. SLS is planned to be taken into service with an initial experimental installation by the middle of 2001. In this brochure an overview is presented on the main characteristics of the SLS facility and on its significance as a tool for interdisciplinary research.

  8. Casimir light: the source.

    OpenAIRE

    1993-01-01

    The release of Casimir energy in filling a dielectric hole is identified as the source of coherent sonoluminescence. Qualitative agreement with recently acquired data is found for the magnitude and shape of the spectrum.

  9. Intermediate-energy light sources

    CERN Document Server

    Corbett, W

    2003-01-01

    Increasingly, atomic scale information underlies scientific and technological progress in disciplines ranging from pharmaceutical development to materials synthesis to environmental remediation. While a variety of research tools are used to provide atomic scale information, synchrotron radiation has proved invaluable in this quest. The rapid growth of soft- and hard X-ray synchrotron light sources stands as stark testimony to the importance and utility of synchrotron radiation. Starting from just a handful of synchrotron light sources in the early 1970s, this burgeoning field now includes over 70 proposed, in-construction, or operating facilities in 23 countries on five continents. Along the way, synchrotron light facilities have evolved from small laboratories extracting light parasitically from storage rings designed for high-energy physics research to large, dedicated sources using the latest technology to produce extraordinarily bright photon beams. The basic layout of a multi-GeV storage ring light sourc...

  10. Compact synchrotron light sources

    CERN Document Server

    Weihreter, Ernst

    1996-01-01

    This book covers a new niche in circular accelerator design, motivated by the promising industrial prospects of recent micromanufacturing methods - X-ray lithography, synchrotron radiation-based micromachining and microanalysis techniques. It describes the basic concepts and the essential challenges for the development of compact synchrotron radiation sources from an accelerator designer's point of view and gives an outline of the actual state of the art. The volume is intended as an introduction and as a reference for physicists, engineers and managers involved in this rapidly developing fiel

  11. Light source modeling for automotive lighting devices

    Science.gov (United States)

    Zerhau-Dreihoefer, Harald; Haack, Uwe; Weber, Thomas; Wendt, Dierk

    2002-08-01

    Automotive lighting devices generally have to meet high standards. For example to avoid discomfort glare for the oncoming traffic, luminous intensities of a low beam headlight must decrease by more than one order of magnitude within a fraction of a degree along the horizontal cutoff-line. At the same time, a comfortable homogeneous illumination of the road requires slowly varying luminous intensities below the cutoff line. All this has to be realized taking into account both, the legal requirements and the customer's stylistic specifications. In order to be able to simulate and optimize devices with a good optical performance different light source models are required. In the early stage of e.g. reflector development simple unstructured models allow a very fast development of the reflectors shape. On the other hand the final simulation of a complex headlamp or signal light requires a sophisticated model of the spectral luminance. In addition to theoretical models based on the light source's geometry, measured luminance data can also be used in the simulation and optimization process.

  12. LIGHT SOURCE: Conceptual design of Hefei advanced light source

    Science.gov (United States)

    Li, Wei-Min; Wang, Lin; Feng, Guang-Yao; Zhang, Shan-Cai; Wu, Cong-Feng; Xu, Hong-Liang; Liu, Zu-Ping

    2009-06-01

    The conceptual of Hefei Advanced Light Source, which is an advanced VUV and Soft X-ray source, was developed at NSRL of USTC. According to the synchrotron radiation user requirements and the trends of SR source development, some accelerator-based schemes were considered and compared; furthermore storage ring with ultra low emittance was adopted as the baseline scheme of HALS. To achieve ultra low emittance, some focusing structures were studied and optimized in the lattice design. Compromising of emittance, on-momentum and off-momentum dynamic aperture and ring scale, five bend acromat (FBA) was employed. In the preliminary design of HALS, the emittance was reduced to sub nm · rad, thus the radiation up to water window has full lateral coherence. The brilliance of undulator radiation covering several eVs to keVs range is higher than that of HLS by several orders. The HALS should be one of the most advanced synchrotron radiation light sources in the world.

  13. Synchrontron VUV and Soft X-Ray Radiation Effects on Aluminized Teflon FEP

    Science.gov (United States)

    Dever, Joyce A.; Townsend, Jacqueline A.; Gaier, James R.; Jalics, Alice I.

    1998-01-01

    Surfaces of the aluminized Teflon FEP multi-layer thermal insulation on the Hubble Space Telescope (HST) were found to be cracked and curled in some areas at the time of the second servicing, mission in February 1997, 6.8 years after HST was deployed in low Earth orbit (LEO). As part of a test program to assess environmental conditions which would produce embrittlement sufficient to cause cracking of Teflon on HST, samples of Teflon FEP with a backside layer of vapor deposited aluminum were exposed to vacuum ultraviolet (VUV) and soft x-ray radiation of various energies using facilities at the National Synchrotron Light Source. Brookhaven National Laboratory. Samples were exposed to synchrotron radiation of narrow energy bands centered on energies between 69 eV and 1900 eV. Samples were analyzed for ultimate tensile strength and elongation. Results will be compared to those of aluminized Teflon FEP retrieved from HST after 3.6 years and 6.8 years on orbit and will he referenced to estimated HST mission doses of VUV and soft x-ray radiation.

  14. INTERMEDIATE-ENERGY LIGHT SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, William

    2002-11-25

    Increasingly, atomic scale information underlies scientific and technological progress in disciplines ranging from pharmaceutical development to materials synthesis to environmental remediation. While a variety of research tools are used to provide atomic scale information, synchrotron radiation has proved invaluable in this quest. The rapid growth of soft- and hard X-ray synchrotron light sources stands as stark testimony to the importance and utility of synchrotron radiation. Starting from just a handful of synchrotron light sources in the early 1970s, this burgeoning field now includes over 70 proposed, in-construction, or operating facilities in 23 countries on five continents. Along the way, synchrotron light facilities have evolved from small laboratories extracting light parasitically from storage rings designed for high-energy physics research to large, dedicated sources using the latest technology to produce extraordinarily bright photon beams. The basic layout of a multi-GeV storage ring light source employs periodic bending magnets to guide a charged particle beam around the storage ring. As the charged beam is accelerated in an arc, it produces a sweeping fan of synchrotron radiation that extends from the infrared part of the electromagnetic spectrum (<1 eV) to hard X rays (>20 keV). Quadrupole magnets keep the electrons tightly focused, and a radio-frequency acceleration system replenishes beam energy lost to radiation emission. To optimize the output radiation, a premium is placed on high current electron beams with small cross section and extreme position stability. Magnetic insertion devices are used to further enhance radiation output by a factor of 10 or more over bend magnet sources. The storage ring vacuum chamber includes exit ports to allow portions of the radiation fan to propagate down photon beam transport lines to optical systems and experimental stations. A typical storage ring features 10 or more such radiation ports. The photon beam

  15. Iranian Light Source Facility, A third generation light source laboratory

    Directory of Open Access Journals (Sweden)

    J Rahighi

    2015-09-01

    Full Text Available The Iranian Light Source Facility (ILSF project is the first large scale accelerator facility which is currently under planning in Iran. On the basis of the present design, circumference of the 3 GeV storage ring is 528 m. Beam current and natural beam emittance are 400 mA and 0.477 nm.rad, respectively. Some prototype accelerator components such as high power solid state radio frequency amplifiers, low level RF system, thermionic RF gun, H-type dipole and quadruple magnets, magnetic measurement laboratory and highly stable magnet power supplies have been constructed at ILSF R&D laboratory

  16. Solid-State Light Sources Getting Smart

    National Research Council Canada - National Science Library

    E. Fred Schubert; Jong Kyu Kim

    2005-01-01

    .... Such "smart" light sources can adjust to specific environments and requirements, a property that could result in tremendous benefits in lighting, automobiles, transportation, communication, imaging, agriculture, and medicine.

  17. Driver circuit for solid state light sources

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, Fred; Denvir, Kerry; Allen, Steven

    2016-02-16

    A driver circuit for a light source including one or more solid state light sources, a luminaire including the same, and a method of so driving the solid state light sources are provided. The driver circuit includes a rectifier circuit that receives an alternating current (AC) input voltage and provides a rectified AC voltage. The driver circuit also includes a switching converter circuit coupled to the light source. The switching converter circuit provides a direct current (DC) output to the light source in response to the rectified AC voltage. The driver circuit also includes a mixing circuit, coupled to the light source, to switch current through at least one solid state light source of the light source in response to each of a plurality of consecutive half-waves of the rectified AC voltage.

  18. Advanced Light Source control system

    Energy Technology Data Exchange (ETDEWEB)

    Magyary, S.; Chin, M.; Cork, C.; Fahmie, M.; Lancaster, H.; Molinari, P.; Ritchie, A.; Robb, A.; Timossi, C.

    1989-03-01

    The Advanced Light Source (ALS) is a third generation 1--2 GeV synchrotron radiation source designed to provide ports for 60 beamlines. It uses a 50 MeV electron linac and 1.5 GeV, 1 Hz, booster synchrotron for injection into a 1--2 GeV storage ring. Interesting control problems are created because of the need for dynamic closed beam orbit control to eliminate interaction between the ring tuning requirements and to minimize orbit shifts due to ground vibrations. The extremely signal sensitive nature of the experiments requires special attention to the sources of electrical noise. These requirements have led to a control system design which emphasizes connectivity at the accelerator equipment end and a large I/O bandwidth for closed loop system response. Not overlooked are user friendliness, operator response time, modeling, and expert system provisions. Portable consoles are used for local operation of machine equipment. Our solution is a massively parallel system with >120 Mbits/sec I/O bandwidth and >1500 Mips computing power. At the equipment level connections are made using over 600 powerful Intelligent Local Controllers (ILC-s) mounted in 3U size Eurocard slots using fiber-optic cables between rack locations. In the control room, personal computers control and display all machine variables at a 10 Hz rate including the scope signals which are collected though the control system. Commercially available software and industry standards are used extensively. Particular attention is paid to reliability, maintainability and upgradeability. 10 refs., 11 figs.

  19. Imitating Broadband Diurnal Light Variations Using Solid State Light Sources

    Science.gov (United States)

    Ferguson, Ian; Melton, Andrew; Li, Nola; Nicol, David; Park, Eun Hyun; Tosini, Gianluca

    Many studies have documented the success of light therapy in treating disorders of the human internal clock (circadian rhythm). Recent biological research has shown the importance of developing light sources that are tunable in the blue region of the spectrum for treatment to be safe and effective. A novel tunable broadband solid-state light source is presented here that mimics the diurnal variation in sunlight by modulating the intensity of blue light emission.

  20. The Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Galayda, John N

    2003-05-21

    A collaboration of scientists from SLAC, UCLA, Los Alamos National Laboratory, Brookhaven National Laboratory, and Argonne National Laboratory have proposed to build the Linac Coherent Light Source (LCLS) facility, a free-electron laser (FEL) on the SLAC site, spanning photon energies 0.8-8 keV. The laser output will be 8-10 GW with pulse lengths 230 fsec or less. The LCLS will offer unprecedented experimental opportunities in the areas of atomic physics, chemical dynamics, plasma physics, nanoscale dynamics, and biomolecular imaging. SLAC has proposed to begin engineering design of the laser in 2003, leading to project completion in 2008. The laser produces x-rays by the self-amplified spontaneous emission (SASE) process: an intense, highly collimated pulse of 14.5 GeV electrons, traveling through a 122 m-long undulator magnet system, is induced by its own synchrotron radiation to form sub-nanometer-scale bunches. The bunching process enhances the coherence and hence the intensity of the emitted synchrotron radiation. The process is analogous to the instability of a high-gain amplifier; the ''noise'' signal that seeds the instability is the shot noise in the electron beam.

  1. Commissioning of SAGA Light Source

    CERN Document Server

    Tomimasu, Takio; Koda, Shigeru; Ohgaki, Hideaki; Takabayashi, Yuichi; Toyokawa, Hiroyuki; Yasumoto, Masato; Yoshida, Katuhide

    2005-01-01

    The SAGA Light Source (SAGA-LS) consists of a 250-MeV electron linac injector and an eight-hold symmetry 1.4-GeV storage ring with eight double-bend (DB) cell and eight 2.93-m long straight sections. The DB cell structure with a distributed dispersion system was chosen to produce a compact ring of 75.6-m long circumference. The machine construction begun September 29, 2003. The ring magnets of steel laminated structure, vacuum chambers made of aluminum alloy, pumping systems and four temperature controlled cooling water systems for the linac accelerating wave guides etc. were installed in March, 2004. The injector, a 500-MHz ring rf damped cavity, rf klystrons, beam transport systems for injection and their controlled systems were installed in July, 2004. The commissioning begun August 25, 2004. A 250-MeV beam was accelerated on September 29. The beam size is 1-mm in diameter and the energy spread is 0.8 % (FWHM). The first revolution of 250-MeV beam around the ring took place October 22. Beam was stored on N...

  2. EDITORIAL: LED light sources (light for the future) LED light sources (light for the future)

    Science.gov (United States)

    Grandjean, N.

    2010-09-01

    comprehensive review of the different localization mechanisms and their implication for internal quantum efficiency (IQE) is proposed by Oliver and co-workers from Cambridge University. When discussing IQE in InGaN-based LEDs, the efficiency droop at high-current injection always emerges, which is a major concern for the future of SSL technology. Here, a collaborative work between Samsung and the Gwangju Institute of Science and Technology (Korea) proves that a specific design of the active region can limit this detrimental effect. Once the issue of the IQE is solved, one still has to let the photons out of the chip. Matioli and Weisbuch from the University of California at Santa Barbara introduce the use of photonic crystals (PhCs) to improve light extraction efficiency. They describe different approaches to overcoming the main limitation of LEDs when implementing surface PhCs. The technology of SSL, and in particular of colour rendering, is tackled by Zukauskas et al who studied in detail different white light sources. They show that extreme colour-fidelity indices need to cover the entire spectrum, with a broad-band at 530-610 nm and a component beyond 610 nm. Then, the reliability of GaN-based LEDs is discussed in the paper of Meneghesso and co-workers. The authors consider the most important physical mechanisms that are (i) the degradation of the active layer of LEDs, (ii) the degradation of the package/phosphor system, (iii) the failure of GaN-based LEDs against electrostatic discharge. Finally, GaN LEDs on silicon developed in the group of Egawa at the Nagoya Institute of Technology are presented. This technology could allow a significant decrease in the fabrication cost of white LEDs.

  3. Increasing the brightness of light sources

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Ling

    2006-11-16

    In this work the principle of light recycling is applied to artificial light sources in order to achieve brightness enhancement. Firstly, the feasibilities of increasing the brightness of light sources via light recycling are examined theoretically, based on the fundamental laws of thermodynamics including Kirchhoff's law on radiation, Planck's law, Lambert-Beer's law, the etendue conservation and the brightness theorem. From an experimental viewpoint, the radiation properties of three different kinds of light sources including short-arc lamps, incandescent lamps and LEDs characterized by their light-generating mechanisms are investigated. These three types of sources are used in light recycling experiments, for the purpose of 1. validating the intrinsic light recycling effect in light sources, e. g. the intrinsic light recycling effect in incandescent lamps stemming from the coiled filament structure. 2. acquiring the required parameters for establishing physical models, e.g. the emissivity/absorptivity of the short-arc lamps, the intrinsic reflectivity and the external quantum efficiency of LEDs. 3. laying the foundations for designing optics aimed at brightness enhancement according to the characteristics of the sources and applications. Based on the fundamental laws and experiments, two physical models for simulating the radiance distribution of light sources are established, one for thermal filament lamps, the other for luminescent sources, LEDs. As validation of the theoretical and experimental investigation of the light recycling effect, an optical device, the Carambola, is designed for achieving deterministic and multiple light recycling. The Carambola has the function of a concentrator. In order to achieve the maximum possible brightness enhancement with the Carambola, several combinations of sources and Carambolas are modelled in ray-tracing simulations. Sources with different light-emitting mechanisms and different radiation properties

  4. Development of a circadian light source

    Science.gov (United States)

    Nicol, David B.; Ferguson, Ian T.

    2002-11-01

    Solid state lighting presents a new paradigm for lighting - controllability. Certain characteristics of the lighting environment can be manipulated, because of the possibility of using multiple LEDs of different emission wavelengths as the illumination source. This will provide a new, versatile, general illumination source due to the ability to vary the spectral power distribution. New effects beyond the visual may be achieved that are not possible with conventional light sources. Illumination has long been the primary function of lighting but as the lighting industry has matured the psychological aspects of lighting have been considered by designers; for example, choosing a particular lighting distribution or color variation in retail applications. The next step in the evolution of light is to consider the physiological effects of lighting that cause biological changes in a person within the environment. This work presents the development of a source that may have important bearing on this area of lighting. A circadian light source has been developed to provide an illumination source that works by modulating its correlated color temperature to mimic the changes in natural daylight through the day. In addition, this source can cause or control physiological effects for a person illuminated by it. The importance of this is seen in the human circadian rhythm's peak response corresponding to blue light at ~460 nm which corresponds to the primary spectral difference in increasing color temperature. The device works by adding blue light to a broadband source or mixing polychromatic light to mimic the variation of color temperature observed for the Planckian Locus on the CIE diagram. This device can have several applications including: a tool for researchers in this area, a general illumination lighting technology, and a light therapy device.

  5. The First Sources of Light

    Science.gov (United States)

    Loeb, Avi

    2011-09-01

    Looking deep into the Universe through powerful telescopes, we can see images of the Universe when it was younger because of the finite time it takes light to travel to us from distant sources. Existing data sets include an image of the Universe when it was 0.4 million years old (in the form of the cosmic microwave background), as well as images of individual galaxies when the Universe was older than a billion years. But there is a serious challenge: in between these two epochs was a period when the Universe was dark, stars had not yet formed, and the cosmic microwave background no longer traced the distribution of matter. And this is precisely the most interesting period, when the primordial soup evolved into the rich zoo of objects we now see. The observers are moving ahead along several fronts. The first involves the construction of large infrared telescopes on the ground and in space, that will provide us with new photos of the first galaxies. Current plans include ground-based telescopes which are 24-42 meter in diameter, and NASA's successor to the Hubble Space Telescope, called the James Webb Space Telescope. In addition, several observational groups around the globe are constructing radio arrays that will be capable of mapping the three-dimensional distribution of cosmic hydrogen in the infant Universe. These arrays are aiming to detect the long-wavelength (redshifted 21-cm) radio emission from hydrogen atoms. The images from these antenna arrays will reveal how the non-uniform distribution of neutral hydrogen evolved with cosmic time and eventually was extinguished by the ultra-violet radiation from the first galaxies. Theoretical research has focused in recent years on predicting the expected signals for the above instruments and motivating these ambitious observational projects.

  6. A compact, coherent light source system architecture

    Science.gov (United States)

    Biedron, S. G.; Dattoli, G.; DiPalma, E.; Einstein, J.; Milton, S. V.; Petrillo, V.; Rau, J. V.; Sabia, E.; Spassovsky, I. P.; van der Slot, P. J. M.

    2016-09-01

    Our team has been examining several architectures for short-wavelength, coherent light sources. We are presently exploring the use and role of advanced, high-peak power lasers for both accelerating the electrons and generating a compact light source with the same laser. Our overall goal is to devise light sources that are more accessible by industry and in smaller laboratory settings. Although we cannot and do not want to compete directly with sources such as third-generation light sources or that of national-laboratory-based free-electron lasers, we have several interesting schemes that could bring useful and more coherent, short-wavelength light source to more researchers. Here, we present and discuss several results of recent simulations and our future steps for such dissemination.

  7. Light Sources Technologies and Applications

    CERN Document Server

    Kitsinelis, Spyridon

    2010-01-01

    From the dialogues of the ancient Greek philosophers right up through the physical laws of Newton, the experiments of Thomas Young and the quantum physics pioneers, the study of light was all about observing its characteristics and defining its behavior. At the end of the 19th century, wicks, wax, and oil gave way to electricity, filaments, and gases, and scientific minds began to focus on the technological creation of light, as well as its control and diverse uses. Yet, despite more than a century of profound research and development, until now, the most complete resources on lighting technol

  8. High-Energy Compton Scattering Light Sources

    CERN Document Server

    Hartemann, Fred V; Barty, C; Crane, John; Gibson, David J; Hartouni, E P; Tremaine, Aaron M

    2005-01-01

    No monochromatic, high-brightness, tunable light sources currently exist above 100 keV. Important applications that would benefit from such new hard x-ray sources include: nuclear resonance fluorescence spectroscopy, time-resolved positron annihilation spectroscopy, and MeV flash radiography. The peak brightness of Compton scattering light sources is derived for head-on collisions and found to scale with the electron beam brightness and the drive laser pulse energy. This gamma 2

  9. Towards the Optimum Light Source Spectrum

    Directory of Open Access Journals (Sweden)

    Andrew Chalmers

    2010-01-01

    Full Text Available This paper is concerned with designing light source spectra for optimum luminous efficacy and colour rendering. We demonstrate that it is possible to design light sources that can provide both good colour rendering and high luminous efficacy by combining the outputs of a number of narrowband spectral constituents. Also, the achievable results depend on the numbers and wavelengths of the different spectral bands utilized in the mixture. Practical realization of these concepts has been demonstrated in this pilot study which combines a number of simulations with tests using real LEDs (light emitting diodes. Such sources are capable of providing highly efficient lighting systems with good energy conservation potential. Further research is underway to investigate the practicalities of our proposals in relation to large-scale light source production.

  10. Supercontinuum light sources for food analysis

    DEFF Research Database (Denmark)

    Møller, Uffe Visbech; Petersen, Christian Rosenberg; Kubat, Irnis

    2014-01-01

    . One track of Light & Food will target the mid-infrared spectral region. To date, the limitations of mid-infraredlight sources, such as thermal emitters, low-power laser diodes, quantum cascade lasers and synchrotron radiation, have precluded mid-IR applications where the spatial coherence, broad...... and in the factory. These solutions will combine bright and broadband infrared light sources, so-called supercontinuum light sources,with spectroscopy, chemometrics and processing expertise and thereby contribute to increased food quality through faster and more precise analysis of grains, soils and dairy products...

  11. COMPARATIVE STUDY OF LIGHT SOURCES FOR HOUSEHOLD

    Directory of Open Access Journals (Sweden)

    Andrzej PAWLAK

    2017-01-01

    Full Text Available The article describes test results that provided the ground to define and evaluate basic photometric, colorimetric and electric parameters of selected, widely available light sources, which are equivalent to a traditional incandescent 60-Watt light bulb. Overall, one halogen light bulb, three compact fluorescent lamps and eleven LED light sources were tested. In general, it was concluded that in most cases (branded products, in particular the measured and calculated parameters differ from the values declared by manufacturers only to a small degree. LED sources prove to be the most beneficial substitute for traditional light bulbs, considering both their operational parameters and their price, which is comparable with the price of compact fluorescent lamps or, in some instances, even lower.

  12. Advanced Light Source Activity Report 2002

    Energy Technology Data Exchange (ETDEWEB)

    Duque, Theresa; Greiner, Annette; Moxon, Elizabeth; Robinson, Arthur; Tamura, Lori (Editors)

    2003-06-12

    This annual report of the Advanced Light Source details science highlights and facility improvements during the year. It also offers information on events sponsored by the facility, technical specifications, and staff and publication information.

  13. National Synchrotron Light Source annual report 1988

    Energy Technology Data Exchange (ETDEWEB)

    Hulbert, S.; Lazarz, N.; Williams, G. (eds.)

    1988-01-01

    This report discusses the experiment done at the National Synchrotron Light Source. Most experiments discussed involves the use of the x-ray beams to study physical properties of solid materials. (LSP)

  14. Advanced Light Source Activity Report 2000

    Energy Technology Data Exchange (ETDEWEB)

    Greiner, A.; Moxon, L.; Robinson, A.; Tamura, L.

    2001-04-01

    This is an annual report, detailing activities at the Advanced Light Source for the year 2000. It includes highlights of scientific research by users of the facility as well as information about the development of the facility itself.

  15. Synchrotron Light Sources in Developing Countries

    Science.gov (United States)

    Winick, Herman; Pianetta, Piero

    2017-01-01

    The more than 50 light sources now in operation around the world include facilities in Brazil, Korea, and Taiwan which started their programs in the 1980's when they were developing countries. They came on line in the 1990's and have since trained hundreds of graduate students locally, without sending them abroad and losing many of them. They have also attracted dozens of mid-career diaspora scientists to return. Their growing user communities have demanded more advanced facilities, leading to the funding of higher performance new light sources that are now coming into operation. Light sources in the developing world now include the following: SESAME in the Middle East which is scheduled to start research in 2017 (www.sesame.org); The African Light Source, in the planning stage (www.africanlightsource.org); and The Mexican Light Source, in the planning stage (http://www.aps.org/units/fip/newsletters/201509/mexico.cfm). See: http://wpj.sagepub.com/content/32/4/92.full.pdf +html; http://www.lightsources.org/press-release/2015/11/20/grenoble-resolutions-mark-historical-step-towards-african-light-source. SLAC National Accelerator Laboratory, is supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Contract No. DE-AC02-76SF00515.

  16. GPC light shaping a supercontinuum source

    DEFF Research Database (Denmark)

    Kopylov, Oleksii; Bañas, Andrew Rafael; Villangca, Mark Jayson;

    2015-01-01

    incorporating various multi-wavelength approaches into spatially shaped excitations that can enable new broadband light applications. We verify this new approach using a supercontinuum light source, interfaced with a compact GPC light shaper. Our experiments give ~70% efficiency, ~3x intensity gain, and ~85......Generalized Phase Contrast (GPC) is a versatile tool for efficiently rerouting and managing photon energy into speckle-free contiguous spatial light distributions. We have previously shown theoretically and numerically that a GPC Light Shaper shows robustness to shift in wavelength and can maintain...... both projection length scale and high efficiency over a range [0.75λ0; 1.5λ0] with λ0 as the characteristic design wavelength. With this performance across multiple wavelengths and the recent availability of tabletop supercontinuum lasers, GPC light shaping opens the possibility for creatively...

  17. IR microscopy utilizing intense supercontinuum light source

    DEFF Research Database (Denmark)

    Dupont, Sune; Petersen, Christian; Thøgersen, Jan;

    2012-01-01

    . The supercontinuum light source has a high brightness and spans the infrared region from 1400 nm to 4000 nm. This combination allows contact free high resolution hyper spectral infrared microscopy. The microscope is demonstrated by imaging an oil/water sample with 20 μm resolution.......Combining the molecular specificity of the infrared spectral region with high resolution microscopy has been pursued by researchers for decades. Here we demonstrate infrared supercontinuum radiated from an optical fiber as a promising new light source for infrared microspectroscopy...

  18. Behavior of Layers under Different Light Sources

    Directory of Open Access Journals (Sweden)

    BO Tavares

    2015-12-01

    Full Text Available ABSTRACT Light is an important factor in the management of laying poultry. The ideal lamp spectrum that provides the best welfare conditions still needs to be determined. Wavelength and light intensity influence poultry behavior and their welfare. This study evaluated the influence of four lamps types with different light spectra on the behavior of seventy 52-week laying hens. Incandescent, fluorescent, and sodium and mercury vapor lamps were set in a different poultry house each and supplied similar light intensities. Layer behavior was video-recorded three times weekly using video cameras installed on the ceiling. The effects of different wavelengths emitted by the light sources on layer behavior were evaluated by the Kruskal-Wallis median test. Results indicated that incandescent and sodium vapor lamps increased the occurrence of nesting, and of active behaviors, such as floor-scratching and pecking.

  19. Solid-State Spectral Light Source System

    Science.gov (United States)

    Maffione, Robert; Dana, David

    2011-01-01

    A solid-state light source combines an array of light-emitting diodes (LEDs) with advanced electronic control and stabilization over both the spectrum and overall level of the light output. The use of LEDs provides efficient operation over a wide range of wavelengths and power levels, while electronic control permits extremely stable output and dynamic control over the output. In this innovation, LEDs are used instead of incandescent bulbs. Optical feedback and digital control are used to monitor and regulate the output of each LED. Because individual LEDs generate light within narrower ranges of wavelengths than incandescent bulbs, multiple LEDs are combined to provide a broad, continuous spectrum, or to produce light within discrete wavebands that are suitable for specific radiometric sensors.

  20. Coherent Light Sources at the Nanoscale

    Science.gov (United States)

    Yang, Ankun; Wang, Danqing; Wang, Weijia; Odom, Teri W.

    2017-05-01

    This review focuses on coherent light sources at the nanoscale, and specifically on lasers exploiting plasmonic cavities that can beat the diffraction limit of light. Conventional lasers exhibit coherent, intense, and directional emission with cavity sizes much larger than their operating wavelength. Plasmon lasers show ultrasmall mode confinement, support strong light-matter interactions, and represent a class of devices with extremely small sizes. We discuss the differences between plasmon lasers and traditional ones, and we highlight advances in directionality and tunability through innovative cavity designs and new materials. Challenges and future prospects are also discussed.

  1. Intrinsically stable light source at telecom wavelengths

    CERN Document Server

    Monteiro, Fernando; Sanguinetti, Bruno; Zbinden, Hugo

    2013-01-01

    We present a highly stable light source at telecom wavelengths, based on a short erbium doped fiber. The high stability arises from the high inversion of the Er3+ion population. This source is developed to work as a stable reference in radiometric applications and is useful in any application where high stability and/or a large bandwidth are necessary. The achieved long-term stability is 10 ppm.

  2. Diamond Light Source: status and perspectives

    OpenAIRE

    Materlik, Gerhard; Rayment, Trevor; Stuart, David I.

    2015-01-01

    Diamond Light Source, a third-generation synchrotron radiation (SR) facility in the UK, celebrated its 10th anniversary in 2012. A private limited company was set up in April 2002 to plan, construct and operate the new user-oriented SR facility, called in brief Diamond. It succeeded the Synchrotron Radiation Source in Daresbury, a second-generation synchrotron that opened in 1980 as the world's first dedicated X-ray-providing facility, closing finally in 2008, by which time Diamond's accelera...

  3. Long-pulse Supercontinuum Light Sources

    DEFF Research Database (Denmark)

    Moselund, Peter M.

    A Supercontinuum (SC) is a broad spectrum generated from a narrow light source through non-linear effects. This thesis describes SC generation based on 1064 nm ps pulses in PCF fibres. We investigate how the SC spectrum can be modified and intensity noise reduced by feeding back part of the SC...

  4. Integrated source of broadband quadrature squeezed light

    DEFF Research Database (Denmark)

    Hoff, Ulrich Busk; Nielsen, Bo Melholt; Andersen, Ulrik Lund

    2015-01-01

    An integrated silicon nitride resonator is proposed as an ultracompact source of bright single-mode quadrature squeezed light at 850 nm. Optical properties of the device are investigated and tailored through numerical simulations, with particular attention paid to loss associated with interfacing...

  5. Momentum aperture of the advanced light source

    Science.gov (United States)

    Decking, W.; Robin, D.

    1999-04-01

    This paper shows measurements of the momentum aperture of the Advanced Light Source (ALS) based on Touschek lifetime measurements. The measured data is compared with tracking simulations and a simple model for the apertures will help to explain the observed effects.

  6. A directly phase-modulated light source

    CERN Document Server

    Yuan, Z L; Lucamarini, M; Roberts, G L; Dynes, J F; Shields, A J

    2016-01-01

    The art of imparting information onto a light wave by optical signal modulation is fundamental to all forms of optical communication. Among many schemes, direct modulation of laser diodes stands out as a simple, robust, and cost effective method. However, the simultaneous changes in intensity, frequency and phase are a drawback which has prevented its application in the field of secure quantum communication. Here, we propose and experimentally demonstrate a directly phase-modulated light source which overcomes the main disadvantages associated with direct modulation and is suitable for diverse applications such as coherent communications and quantum cryptography. The source separates the tasks of phase preparation and pulse generation between a pair of semiconductor lasers leading to very pure phase states. Moreover, the cavity enhanced electro-optic effect enables the first example of sub-volt halfwave phase modulation at high signal rates. The source is compact, stable and versatile, and we show its potenti...

  7. Superluminescent Diode Light Sources for OCT

    Science.gov (United States)

    Shidlovski, Vladimir R.

    Contrary to laser diodes, the path of superluminescent diodes (SLDs) to widespread practical use was much longer. There was always a scientific interest in "superluminescent" light output from laser diode structures slightly below threshold that might be considerably enhanced by "damping" of the laser resonator. SLD design efforts were intensified in early 1980s when it was proved that they are "light sources of choice" for fiber-optic gyroscopes. The next wave of interest to SLDs as a "stand-alone" type of semiconductor emitters was related to advances in OCT technologies. Challenging OCT requirements, e.g. simultaneous high-power, high brightness and very low coherence length of a light source, resulted in the development of new generation of SLDs characterized by output power and brightness the same as that of medium-to-high power laser diodes, but with the spectral width and flatness of edge-emitting LEDs. In this chapter, the main principles of the development of powerful broadband SLDs and ultra-low-coherence SLD-based light sources in 650-1600 nm spectral range, and the main parameters reported to date, are reviewed. Important aspects of SLD use in practice are discussed.

  8. Pioneering SESAME light source officially opened

    CERN Multimedia

    Caraban Gonzalez, Noemi

    2017-01-01

    Allan, Jordan, 16 May 2017. The SESAME light source was today officially opened by His Majesty King Abdullah II. An intergovernmental organization, SESAME is the first regional laboratory for the Middle East and neighbouring regions The laboratory’s official opening ushers in a new era of research covering fields ranging from medicine and biology, through materials science, physics and chemistry to healthcare, the environment, agriculture and archaeology.

  9. RF Sources for 3rd & 4th Generation Light Sources

    CERN Document Server

    Lenci, Stephan; Bohlen, Heinz Peter; Mizuhara, Albert; Wright, Edward L

    2004-01-01

    The growing number of third and fourth generation light sources has resulted in an increase of the available rf sources to power them. Single beam klystrons are the traditional power source, but the development of IOT’s and multiple-beam klystrons (MBK’s) in L-Band have increased the options for these machines. The Eimac division of CPI has recently built and tested a prototype L-Band IOT, which delivered 30 kW CW at 1.3 GHz. Future work includes the building of an IOT at 1.5 GHz. Meanwhile the MPP division of CPI is currently testing the prototype 10 MW peak, 1.3 GHz MBK for the TESLA x-ray free-electron laser (XFEL). Test results for these new products as well as information on all CPI products at 500 MHz, 1.3 GHz, and 1.5 GHz will be presented.

  10. The JLab high power ERL light source

    Energy Technology Data Exchange (ETDEWEB)

    G.R. Neil; C. Behre; S.V. Benson; M. Bevins; G. Biallas; J. Boyce; J. Coleman; L.A. Dillon-Townes; D. Douglas; H.F. Dylla; R. Evans; A. Grippo; D. Gruber; J. Gubeli; D. Hardy; C. Hernandez-Garcia; K. Jordan; M.J. Kelley; L. Merminga; J. Mammosser; W. Moore; N. Nishimori; E. Pozdeyev; J. Preble; R. Rimmer; Michelle D. Shinn; T. Siggins; C. Tennant; R. Walker; G.P. Williams and S. Zhang

    2005-03-19

    A new THz/IR/UV photon source at Jefferson Lab is the first of a new generation of light sources based on an Energy-Recovered, (superconducting) Linac (ERL). The machine has a 160 MeV electron beam and an average current of 10 mA in 75 MHz repetition rate hundred femtosecond bunches. These electron bunches pass through a magnetic chicane and therefore emit synchrotron radiation. For wavelengths longer than the electron bunch the electrons radiate coherently a broadband THz {approx} half cycle pulse whose average brightness is > 5 orders of magnitude higher than synchrotron IR sources. Previous measurements showed 20 W of average power extracted[1]. The new facility offers simultaneous synchrotron light from the visible through the FIR along with broadband THz production of 100 fs pulses with >200 W of average power. The FELs also provide record-breaking laser power [2]: up to 10 kW of average power in the IR from 1 to 14 microns in 400 fs pulses at up to 74.85 MHz repetition rates and soon will produce similar pulses of 300-1000 nm light at up to 3 kW of average power from the UV FEL. These ultrashort pulses are ideal for maximizing the interaction with material surfaces. The optical beams are Gaussian with nearly perfect beam quality. See www.jlab.org/FEL for details of the operating characteristics; a wide variety of pulse train configurations are feasible from 10 microseconds long at high repetition rates to continuous operation. The THz and IR system has been commissioned. The UV system is to follow in 2005. The light is transported to user laboratories for basic and applied research. Additional lasers synchronized to the FEL are also available. Past activities have included production of carbon nanotubes, studies of vibrational relaxation of interstitial hydrogen in silicon, pulsed laser deposition and ablation, nitriding of metals, and energy flow in proteins. This paper will present the status of the system and discuss some of the discoveries we have made

  11. Directly Phase-Modulated Light Source

    Science.gov (United States)

    Yuan, Z. L.; Fröhlich, B.; Lucamarini, M.; Roberts, G. L.; Dynes, J. F.; Shields, A. J.

    2016-07-01

    The art of imparting information onto a light wave by optical signal modulation is fundamental to all forms of optical communication. Among many schemes, direct modulation of laser diodes stands out as a simple, robust, and cost-effective method. However, the simultaneous changes in intensity, frequency, and phase have prevented its application in the field of secure quantum communication. Here, we propose and experimentally demonstrate a directly phase-modulated light source which overcomes the main disadvantages associated with direct modulation and is suitable for diverse applications such as coherent communications and quantum cryptography. The source separates the tasks of phase preparation and pulse generation between a pair of semiconductor lasers leading to very pure phase states. Moreover, the cavity-enhanced electro-optic effect enables the first example of subvolt half-wave phase modulation at high signal rates. The source is compact, stable, and versatile, and we show its potential to become the standard transmitter for future quantum communication networks based on attenuated laser pulses.

  12. Superbend upgrade on the Advanced Light Source

    Science.gov (United States)

    Robin, D.; Krupnick, J.; Schlueter, R.; Steier, C.; Marks, S.; Wang, B.; Zbasnik, J.; Benjegerdes, R.; Biocca, A.; Bish, P.; Brown, W.; Byrne, W.; Chen, J.; Decking, W.; DeVries, J.; DeMarco, W. R.; Fahmie, M.; Geyer, A.; Harkins, J.; Henderson, T.; Hinkson, J.; Hoyer, E.; Hull, D.; Jacobson, S.; McDonald, J.; Molinari, P.; Mueller, R.; Nadolski, L.; Nishimura, H.; Nishimura, K.; Ottens, F.; Paterson, J. A.; Pipersky, P.; Portmann, G.; Ritchie, A.; Rossi, S.; Salvant, B.; Scarvie, T.; Schmidt, A.; Spring, J.; Taylor, C.; Thur, W.; Timossi, C.; Wandesforde, A.

    2005-02-01

    The Advanced Light Source (ALS) is a third generation synchrotron light source at Lawrence Berkeley National Laboratory (LBNL). There was an increasing demand for additional high brightness hard X-ray beamlines in the 7-40 keV range, so in August 2001, three 1.3 T normal conducting bending magnets were removed from the storage ring and replaced with 5 T superconducting magnets (Superbends). The radiation produced by these Superbends is an order of magnitude higher in photon brightness and flux at 12 keV, making them excellent sources of hard X-rays for protein crystallography and other hard X-ray applications. The Superbends did not compromise the performance of the facility in the VUV and soft X-ray regions of the spectrum. The Superbends will eventually feed 12 new beam lines, greatly enhancing the facility's capability and capacity in the hard X-ray region. The Superbend project is the biggest upgrade since the ALS storage ring was commissioned in 1993. In this paper we present an overview of the Superbend project, its challenges and the resulting impact on the ALS.

  13. Plasma-based EUV light source

    Science.gov (United States)

    Shumlak, Uri; Golingo, Raymond; Nelson, Brian A.

    2010-11-02

    Various mechanisms are provided relating to plasma-based light source that may be used for lithography as well as other applications. For example, a device is disclosed for producing extreme ultraviolet (EUV) light based on a sheared plasma flow. The device can produce a plasma pinch that can last several orders of magnitude longer than what is typically sustained in a Z-pinch, thus enabling the device to provide more power output than what has been hitherto predicted in theory or attained in practice. Such power output may be used in a lithography system for manufacturing integrated circuits, enabling the use of EUV wavelengths on the order of about 13.5 nm. Lastly, the process of manufacturing such a plasma pinch is discussed, where the process includes providing a sheared flow of plasma in order to stabilize it for long periods of time.

  14. Chemical Dynamics at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Baer, T.; Berrah, N.; Fadley, C.; Moore, C.B.; Neumark, D.M.; Ng, C.Y.; Ruscic, B.; Smith, N.V.; Suits, A.G.; Wodtke, A.M.

    1999-02-02

    A day-long retreat was held January 15, 1999 to chart the future directions for chemical dynamics studies at the Advanced Light Source. This represents an important period for the Chemical Dynamics Beamline, as the hardware is well-developed, most of the initial experimental objectives have been realized and the mission is now to identify the future scientific priorities for the beamline and attract users of the highest caliber. To this end, we have developed a detailed scientific program for the near term; identified and prioritized the long range scientific opportunities, identified essential new hardware, and outlined an aggressive outreach program to involve the chemical physics community.

  15. Fundamentals of light sources and lasers

    CERN Document Server

    Csele, Mark

    2011-01-01

    A comprehensive introduction to the burgeoning field of photonicsThe field of photonics is finding increasing applications across a broad range of industries. While many other books provide an overview of the subject, Fundamentals of Light Sources and Lasers closes a clear gap in the current literature by concentrating on the principles of laser operation as well as providing coverage of important concepts necessary to fully understand the principles involved. The scope of the book includes everything a professional needs to get up to speed in the field, as well as all the material necessa

  16. Integrated source of broadband quadrature squeezed light

    DEFF Research Database (Denmark)

    Hoff, Ulrich Busk; Nielsen, Bo Melholt; Andersen, Ulrik Lund

    2015-01-01

    An integrated silicon nitride resonator is proposed as an ultracompact source of bright single-mode quadrature squeezed light at 850 nm. Optical properties of the device are investigated and tailored through numerical simulations, with particular attention paid to loss associated with interfacing...... squeezing spectrum for intra-cavity pump self-phase modulation. Subject to standard material loss and detection efficiencies, we find that the device holds promises for generating substantial quantum noise squeezing over a bandwidth exceeding 1 GHz. In the low-propagation loss regime, approximately -6 d...

  17. Status of the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Galayda, John N.; /SLAC

    2011-11-04

    The Linac Coherent Light Source (LCLS) is a free electron laser facility in construction at Stanford Linear Accelerator Center. It is designed to operate in the wavelength range 0.15-1.5 nanometers. At the time of this conference, civil construction of new tunnels and buildings is complete, the necessary modifications to the SLAC linac are complete, and the undulator system and x-ray optics/diagnostics are being installed. The electron gun, 135 MeV injector linac and 250 MeV bunch compressor were commissioned in 2007. Accelerator commissioning activities are presently devoted to the achievement of performance goals for the completed 14 GeV linac.

  18. Coded source imaging simulation with visible light

    Science.gov (United States)

    Wang, Sheng; Zou, Yubin; Zhang, Xueshuang; Lu, Yuanrong; Guo, Zhiyu

    2011-09-01

    A coded source could increase the neutron flux with high L/ D ratio. It may benefit a neutron imaging system with low yield neutron source. Visible light CSI experiments were carried out to test the physical design and reconstruction algorithm. We used a non-mosaic Modified Uniformly Redundant Array (MURA) mask to project the shadow of black/white samples on a screen. A cooled-CCD camera was used to record the image on the screen. Different mask sizes and amplification factors were tested. The correlation, Wiener filter deconvolution and Richardson-Lucy maximum likelihood iteration algorithm were employed to reconstruct the object imaging from the original projection. The results show that CSI can benefit the low flux neutron imaging with high background noise.

  19. Wavelength-tunable duplex integrated light source

    Science.gov (United States)

    Okamoto, Hiroshi; Yasaka, Hiroshi; Oe, Kunishige

    1996-04-01

    A monolithically integrated opto-electronic device is proposed as a fast wavelength-switching light source. This tunable duplex integrated light source comprises two wavelength-tunable distributed Bragg reflector (DBR) laser diodes (LDs), two MQW-electro-absorption optical switches, a Y-shaped waveguide coupler, a MQW-electro-absorption modulator, and two thermal drift compensators (TDCs). The wavelength-switching time of the optical switches was estimated to be 60 ps including a 50-ps rise time for the electrical-pulse generator. The wavelength of a 10-Gbit/s NRZ-modulated optical signal can be switched without bit loss. The function of the TDCs is to keep the device-chip temperature constant. Thermal-transient- induced wavelength drift with a millisecond-order time constant, which has been reported for DBR-LDs, and thermal crosstalk between the tuning regions of the integrated LDs, which causes wavelength fluctuation, are effectively suppressed by thermal-drift-compensation operation using the TDCs.

  20. A novel amblyopia treatment system based on LED light source

    Science.gov (United States)

    Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling

    2011-05-01

    A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.

  1. The Linac Coherent Light Source Project

    Energy Technology Data Exchange (ETDEWEB)

    Galayda, John N

    2003-08-11

    The Linac Coherent Light Source Project will make use of the last kilometer of the SLAC Linac to create the world's first ''hard'' x-ray laser. A high-brightness photocathode gun and 150 MeV pre-accelerator will be installed in an alcove adjoining the main linac tunnel. It will provide 1 nanocoulomb electron bunches at 120 Hz. The main linac will be modified to incorporate two chicane bunch compressors. Electron bunches with 230 fsec FWHM duration and 3400 ampere peak current will be delivered to the enclosure presently housing the Final Focus Test Beam Facility. These electron bunches will pass through a 122-meter undulator channel, producing a burst of coherent x-rays with peak brightness ten orders of magnitude higher than is presently available from the brightest third-generation storage ring sources. This extraordinary brightness and coherence is the result of the ''self-amplified spontaneous emission'' (SASE) process. The LCLS Project will include x-ray optics, diagnostics and beamline facilities in two experiment halls, respectively located 40 meters and 322 meters from the source of x-rays. The LCLS will be constructed by a collaboration of US laboratories: Argonne National Labs, Lawrence Livermore National Lab, and SLAC. A conceptual design has been completed and funds for a more complete design are expected in October 2002. The Project completion date is September 2008.

  2. Energy Recovery Linacs for Light Source Applications

    Energy Technology Data Exchange (ETDEWEB)

    George Neil

    2011-04-01

    Energy Recovery Linacs are being considered for applications in present and future light sources. ERLs take advantage of the continuous operation of superconducting rf cavities to accelerate high average current beams with low losses. The electrons can be directed through bends, undulators, and wigglers for high brightness x ray production. They are then decelerated to low energy, recovering power so as to minimize the required rf drive and electrical draw. When this approach is coupled with advanced continuous wave injectors, very high power, ultra-short electron pulse trains of very high brightness can be achieved. This paper will review the status of worldwide programs and discuss the technology challenges to provide such beams for photon production.

  3. Nonclassical light sources for silicon photonics

    Science.gov (United States)

    Bajoni, Daniele; Galli, Matteo

    2017-09-01

    Quantum photonics has recently attracted a lot of attention for its disruptive potential in emerging technologies like quantum cryptography, quantum communication and quantum computing. Driven by the impressive development in nanofabrication technologies and nanoscale engineering, silicon photonics has rapidly become the platform of choice for on-chip integration of high performing photonic devices, now extending their functionalities towards quantum-based applications. Focusing on quantum Information Technology (qIT) as a key application area, we review recent progress in integrated silicon-based sources of nonclassical states of light. We assess the state of the art in this growing field and highlight the challenges that need to be overcome to make quantum photonics a reliable and widespread technology.

  4. LED intense headband light source for fingerprint analysis

    Energy Technology Data Exchange (ETDEWEB)

    Villa-Aleman, Eliel

    2005-03-08

    A portable, lightweight and high-intensity light source for detecting and analyzing fingerprints during field investigation. On-site field analysis requires long hours of mobile analysis. In one embodiment, the present invention comprises a plurality of light emitting diodes; a power source; and a personal attachment means; wherein the light emitting diodes are powered by the power source, and wherein the power source and the light emitting diodes are attached to the personal attachment means to produce a personal light source for on-site analysis of latent fingerprints. The present invention is available for other applications as well.

  5. LED intense headband light source for fingerprint analysis

    Science.gov (United States)

    Villa-Aleman, Eliel

    2005-03-08

    A portable, lightweight and high-intensity light source for detecting and analyzing fingerprints during field investigation. On-site field analysis requires long hours of mobile analysis. In one embodiment, the present invention comprises a plurality of light emitting diodes; a power source; and a personal attachment means; wherein the light emitting diodes are powered by the power source, and wherein the power source and the light emitting diodes are attached to the personal attachment means to produce a personal light source for on-site analysis of latent fingerprints. The present invention is available for other applications as well.

  6. Spectral design of new dynamic LED light sources

    DEFF Research Database (Denmark)

    Thorseth, Anders

    The use of LED technology in lighting applications, termed Solid State Lighting, is increasing drastically these years due to increasing flux and efficiency of LED components. The advantages of using Solid State Lighting is not only energy savings but the possibility to create new dynamic light...... sources that can be varied in color temperature and achieving color rendering properties. New LED light sources are constructed as clusters of colored LEDs. Modeling and optimization of the control of the light from the individual LEDs is a necessity for the desired operation of the new dynamic light...... source. Detailed knowledge of the spectral power distribution as a function of operating current and temperature is required for the modeling and optimization. Examples of new high color quality dynamic white light sources that can be tuned from warm white light at 2700 K to cold white light at 6500 K...

  7. Status of the Metrology Light Source

    Science.gov (United States)

    Klein, R.; Ulm, G.; Feikes, J.; Hartrott, M. v.; Wüstefeld, G.

    2010-06-01

    The Physikalisch-Technische Bundesanstalt (PTB), the German national metrology institute, has set up the low-energy electron storage ring Metrology Light Source (MLS) in close cooperation with the Helmholtz-Zentrum Berlin (HZB, formerly BESSY). This new storage ring has been in regular user operation since April 2008 and is dedicated to synchrotron-radiation-based metrology and technological developments in the far-IR/THz, IR, UV, VUV and EUV spectral range. The MLS has a double-bend-achromate lattice structure, injection is from a 105 MeV racetrack microtron. The electron energy can be ramped to any value from 105 MeV up to 630 MeV and the electron beam current covers the range from one stored electron (1 pA) up to 200 mA. The MLS is the first electron storage ring optimized for the generation of coherent synchrotron radiation, based on an electron bunch shortening mode. In this mode, MLS delivers coherent radiation in the far-IR/THz spectral range with enhanced intensity as compared to the normal mode of operation. Several beamlines are in operation or in construction, including one undulator beamline, bending magnet beamlines for the calibration of radiation sources and detectors and for reflectometry, an EUV metrology beamline and three IR/THz beamlines.

  8. Diamond Light Source: status and perspectives.

    Science.gov (United States)

    Materlik, Gerhard; Rayment, Trevor; Stuart, David I

    2015-03-06

    Diamond Light Source, a third-generation synchrotron radiation (SR) facility in the UK, celebrated its 10th anniversary in 2012. A private limited company was set up in April 2002 to plan, construct and operate the new user-oriented SR facility, called in brief Diamond. It succeeded the Synchrotron Radiation Source in Daresbury, a second-generation synchrotron that opened in 1980 as the world's first dedicated X-ray-providing facility, closing finally in 2008, by which time Diamond's accelerators and first beamlines were operating and user experiments were under way. This theme issue of Philosophical Transactions of the Royal Society A gives some examples of the rich diversity of research done in the initial five years, with some glimpses of activity up to 2014. Speakers at the 10 year anniversary symposium were drawn from a small number of major thematic areas and each theme was elaborated by a few speakers whose contributions were placed into a broader context by a leading member of the UK academic community in the role of rapporteur. This introduction gives a summary of the design choices and strategic planning of Diamond as a coherent user facility, a snapshot of its present status and some consideration of future perspectives.

  9. The 4th Generation Light Source at Jefferson Lab

    Energy Technology Data Exchange (ETDEWEB)

    Stephen Benson; George Biallas; James Boyce; Donald Bullard; James Coleman; David Douglas; H. Dylla; Richard Evans; Pavel Evtushenko; Albert Grippo; Christopher Gould; Joseph Gubeli; David Hardy; Carlos Hernandez-Garcia; Kevin Jordan; John Klopf; Steven Moore; George Neil; Thomas Powers; Joseph Preble; Daniel Sexton; Michelle D. Shinn; Christopher Tennant; Richard Walker; Shukui Zhang; Gwyn Williams

    2007-04-25

    A number of "Grand Challenges" in Science have recently been identified in reports from The National Academy of Sciences, and the U.S. Dept. of Energy, Basic Energy Sciences. Many of these require a new generation of linac-based light source to study dynamical and non-linear phenomena in nanoscale samples. In this paper we present a summary of the properties of such light sources, comparing them with existing sources, and then describing in more detail a specific source at Jefferson Lab. Importantly, the JLab light source has developed some novel technology which is a critical enabler for other new light sources.

  10. National Synchrotron Light Source 2008 Activity Report

    Energy Technology Data Exchange (ETDEWEB)

    Nasta,K.

    2009-05-01

    Funded by the U.S. Department of Energy's Office of Basic Energy Sciences, the National Synchrotron Light Source (NSLS) is a national user facility that operates two electron storage rings: X-Ray (2.8 GeV, 300 mA) and Vacuum Ultraviolet (VUV) (800 mev, 1.0A). These two rings provide intense light spanning the electromagnetic spectrum -- from very long infrared rays to ultraviolet light and super-short x-rays -- to analyze very small or highly dilute samples. The properties of this light, and the specially designed experimental stations, called beamlines, allow scientists in many diverse disciplines of research to perform experiments not possible at their own laboratories. Each year, about 2,200 scientists from more than 400 universities and companies use the NSLS for research in such diverse fields as biology, physics, chemistry, geology, medicine, and environmental and materials sciences. For example, researchers have used the NSLS to examine the minute details of computer chips, decipher the structures of viruses, probe the density of bone, determine the chemical composition of moon rocks, and reveal countless other mysteries of science. The facility has 65 operating beamlines, with 51 beamlines on the X-Ray Ring and 14 beamlines on the VUV-Infrared Ring. It runs seven days a week, 24 hours a day throughout the year, except during periods of maintenance and studies. Researchers are not charged for beam time, provided that the research results are published in open literature. Proprietary research is conducted on a full-cost-recovery basis. With close to 1,000 publications per year, the NSLS is one of the most prolific scientific facilities in the world. Among the many accolades given to its users and staff, the NSLS has won nine R&D 100 Awards for innovations ranging from a closed orbit feedback system to the first device able to focus a large spread of high-energy x-rays. In addition, a visiting NSLS researcher shared the 2003 Nobel Prize in Chemistry for

  11. The Sun: the Earth light source

    Science.gov (United States)

    Berrilli, Francesco; Giovannelli, Luca; Del Moro, Dario; Piazzesi, Roberto; Catena, Liu` Maria; Amicucci, Giordano; Vittorio, Nicola

    2015-04-01

    We have implemented at Department of Physics of University of Rome Tor Vergata a project called "The Sun: the Earth light source". The project obtained the official endorsement from the IAU Executive Committee Working Group for the International Year of Light. The project, specifically designed for high school students, is focused on the "scientific" study of Sun light by means of a complete acquisition system based on "on the shelf" appropriately CMOS low-cost sensor with free control s/w and self-assembled telescopes. The project (hereafter stage) plan is based on a course of two weeks (60 hours in total). The course contains 20 hours of theoretical lectures, necessary to learn basics about Sun, optics, telescopes and image sensors, and 40 hours of laboratory. During the course, scientists and astronomers share with high schools students, work activities in real research laboratories. High schools teachers are intensely involved in the project. Their role is to share activities with university teachers and realize outreach actions in the home institutions. Simultaneously, they are introduced to innovative teaching methods and the project in this way is regarded as a professional development course. Sun light analysis and Sun-Earth connection through light are the main scientific topics of this project. The laboratory section of the stage is executed in two phases (weeks): First phase aims are the realization of a keplerian telescope and low-cost acquisition system. During this week students are introduced to astronomical techniques used to safety collect and acquire solar light; Second phase aims is the realization of a low-cost instrument to analyse sunlight extracting information about the solar spectrum, solar irradiance and Sun-Earth connection. The proposed stage has been already tested in Italy reached the fifth edition in 2014. Since 2010, the project has been a cornerstone outreach program of the University of Rome Tor Vergata, the Italian Ministry of

  12. LIGHT SOURCE: TW Laser system for Thomson scattering X-ray light source at Tsinghua University

    Science.gov (United States)

    Yan, Li-Xm; Du, Ying-Chao; Du, Qiang; Li, Ren-Kai; Hua, Jian-Fei; Huang, Wen-Hui; Tang, Chuan-Xiang

    2009-06-01

    A TW (Tera Watt) laser system based on Ti:sapphire mainly for the Tsinghua Thomson scattering X-ray light source (TTX) is being built. Both UV (ultraviolet) laser pulse for driving the photocathode radio-frequency (RF) gun and the IR (infrared) laser pulse as the electron-beam-scattered-light are provided by the system. Efforts have also been made in laser pulse shaping and laser beam transport to optimize the high-brightness electron beam production by the photocathode RF gun.

  13. The Jefferson Lab High Power Light Source

    Energy Technology Data Exchange (ETDEWEB)

    James R. Boyce

    2006-01-01

    Jefferson Lab has designed, built and operated two high average power free-electron lasers (FEL) using superconducting RF (SRF) technology and energy recovery techniques. Between 1999-2001 Jefferson Lab operated the IR Demo FEL. This device produced over 2 kW in the mid-infrared, in addition to producing world record average powers in the visible (50 W), ultraviolet (10 W) and terahertz range (50 W) for tunable, short-pulse (< ps) light. This FEL was the first high power demonstration of an accelerator configuration that is being exploited for a number of new accelerator-driven light source facilities that are currently under design or construction. The driver accelerator for the IR Demo FEL uses an Energy Recovered Linac (ERL) configuration that improves the energy efficiency and lowers both the capital and operating cost of such devices by recovering most of the power in the spent electron beam after optical power is extracted from the beam. The IR Demo FEL was de-commissioned in late 2001 for an upgraded FEL for extending the IR power to over 10 kW and the ultraviolet power to over 1 kW. The FEL Upgrade achieved 10 kW of average power in the mid-IR (6 microns) in July of 2004, and its IR operation currently is being extended down to 1 micron. In addition, we have demonstrated the capability of on/off cycling and recovering over a megawatt of electron beam power without diminishing machine performance. A complementary UV FEL will come on-line within the next year. This paper presents a summary of the FEL characteristics, user community accomplishments with the IR Demo, and planned user experiments.

  14. LIGHT SOURCE: Conceptual design of Hefei Advanced Light Source (HALS) injection system

    Science.gov (United States)

    Zhang, Shan-Cai; Wang, Lin; Feng, Guang-Yao; Wu, Cong-Feng; Li, Wei-Min; Xu, Hong-Liang; Liu, Zu-Ping

    2009-06-01

    The Hefei Advanced Light Source(HALS) is a super low emittance storage ring and has a very short beam life time. In order to run the ring stablely, top-up injection will be necessary. The injection system will greatly affect the quality of beam. This article first gives a physics design of the injecting system. Then the injecting system is tracked under different errors. The responses of storage beam and injecting beam are given in the article.

  15. Progress of the Synchrotron Light Source ALBA

    CERN Document Server

    Einfeld, Dieter; Campmany, Josep; Muñoz, Marc; Pont, Montserrat

    2005-01-01

    ALBA will be a third generation synchrotron light source built in Spain near Barcelona. Commissioning of the storage ring is foreseen to start at the end of 2008. The design phase of ALBA is almost completed and the first components are ready to be ordered. A 100 MeV LINAC will inject electrons into a nominal energy booster synchrotron of similar circumference as the storage ring, so that both accelerators will share the same tunnel. The storage ring, working at 3 GeV with a circumference of 268.8 m, has been designed for a maximum current of 400 mA. The lattice is based on an extended DBA structure and has a nominal emittance of 4 nm.rad.The machine has a four fold symmetry with 4 long straight sections (8 m), 12 medium (4.2 m) and 8 short (2.6 m). This report concentrates on recent design developments, component choices and current status. Another paper at this conference deals with accelerator physics issues.

  16. Matrix light and pixel light: optical system architecture and requirements to the light source

    Science.gov (United States)

    Spinger, Benno; Timinger, Andreas L.

    2015-09-01

    Modern Automotive headlamps enable improved functionality for more driving comfort and safety. Matrix or Pixel light headlamps are not restricted to either pure low beam functionality or pure high beam. Light in direction of oncoming traffic is selectively switched of, potential hazard can be marked via an isolated beam and the illumination on the road can even follow a bend. The optical architectures that enable these advanced functionalities are diverse. Electromechanical shutters and lens units moved by electric motors were the first ways to realize these systems. Switching multiple LED light sources is a more elegant and mechanically robust solution. While many basic functionalities can already be realized with a limited number of LEDs, an increasing number of pixels will lead to more driving comfort and better visibility. The required optical system needs not only to generate a desired beam distribution with a high angular dynamic, but also needs to guarantee minimal stray light and cross talk between the different pixels. The direct projection of the LED array via a lens is a simple but not very efficient optical system. We discuss different optical elements for pre-collimating the light with minimal cross talk and improved contrast between neighboring pixels. Depending on the selected optical system, we derive the basic light source requirements: luminance, surface area, contrast, flux and color homogeneity.

  17. National Synchrotron Light Source 2010 Activity Report

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, M.; Snyder, K. J.

    2010-12-29

    This is a very exciting period for photon sciences at Brookhaven National Laboratory. It is also a time of unprecedented growth for the Photon Sciences Directorate, which operates the National Synchrotron Light Source (NSLS) and is constructing NSLS-II, both funded by the Department of Energy's Office of Science. Reflecting the quick pace of our activities, we chose the theme 'Discovery at Light Speed' for the directorate's 2010 annual report, a fiscal year bookended by October 2009 and September 2010. The year began with the news that NSLS users Venki Ramakrishnan of Cambridge University (also a former employee in Brookhaven's biology department) and Thomas A. Steitz of Yale University were sharing the 2009 Nobel Prize in Chemistry with Ada E. Yonath of the Weizmann Institute of Science. Every research project has the potential for accolades. In 2010, NSLS users and staff published close to 900 papers, with about 170 appearing in premiere journals. Those are impressive stats for a facility nearly three decades old, testament to the highly dedicated team keeping NSLS at peak performance and the high quality of its user community. Our NSLS users come from a worldwide community of scientists using photons, or light, to carry out research in energy and environmental sciences, physics, materials science, chemistry, biology and medicine. All are looking forward to the new capabilities enabled by NSLS-II, which will offer unprecedented resolution at the nanoscale. The new facility will produce x-rays more than 10,000 times brighter than the current NSLS and host a suite of sophisticated instruments for cutting-edge science. Some of the scientific discoveries we anticipate at NSLS-II will lead to major advances in alternative energy technologies, such as hydrogen and solar. These discoveries could pave the way to: (1) catalysts that split water with sunlight for hydrogen production; (2) materials that can reversibly store large quantities of

  18. Study and Application of Foreign Gaseous Tritium Light Sources

    Institute of Scientific and Technical Information of China (English)

    DENG; Bei; LI; Si-jie; ZHANG; Li-feng; SUN; Yu-hua; HAN; Shi-quan

    2013-01-01

    Light is given out by the phosphor material which is excited by theβrays from tritium,as is the way tritium light sources work.For tritium light sources,there is no need for maintenance and additional power,and it is not affected by temperature,humidity,altitude and use technology,which makes it widely used in some special areas of national economy,just like the sight lighting of varieties of instrument panel,

  19. Intermediate energy light sources and the SSRF project

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Advances in insertion device technology, top-up operation and superconducting RF cavities make it possible to generate high brightness X-ray with intermediate energy light sources, which leads a new trend in designing and constructing third generation light sources around the world. The development status and the remarkable technical features of intermediate energy light sources are reviewed, and the main SSRF properties are described in this paper.

  20. Behavior of Layers under Different Light Sources

    OpenAIRE

    2015-01-01

    ABSTRACT Light is an important factor in the management of laying poultry. The ideal lamp spectrum that provides the best welfare conditions still needs to be determined. Wavelength and light intensity influence poultry behavior and their welfare. This study evaluated the influence of four lamps types with different light spectra on the behavior of seventy 52-week laying hens. Incandescent, fluorescent, and sodium and mercury vapor lamps were set in a different poultry house each and supplied...

  1. LAT Monitored Source List Light Curves

    Data.gov (United States)

    National Aeronautics and Space Administration — The LAT team monitors flux values for a number of bright sources and transient sources that have shown flares during the mission. (See up-to-date weekly reports on...

  2. Perception of light source distance from shading patterns.

    Science.gov (United States)

    Schütt, Heiko H; Baier, Franziska; Fleming, Roland W

    2016-01-01

    Varying the distance of a light source from an object alters both the intensity and spatial distribution of surface shading patterns. We tested whether observers can use such cues to infer light source distance. Participants viewed stereoscopic renderings of rough objects with diffuse and glossy surfaces, which were illuminated by a point source at a range of distances. In one task, they adjusted the position of a small probe dot in three dimensions to report the apparent location of the light in the scene. In a second task, they adjusted the shading on one object (by moving an invisible light source) until it appeared to be illuminated from the same distance as another object. Participants' responses increased linearly with the true light source distance, suggesting that they have clear intuitions about how light source distance affects shading patterns for a variety of different surfaces. However, there were also systematic errors: Subjects overestimated light source distance in the probe adjustment task, and in both experiments, roughness and glossiness affected responses. We find the pattern of results is predicted surprisingly well by a simplistic model based only on the area of the image that exceeds a certain intensity threshold. Thus, although subjects can report light source distance, they may rely on simple--sometimes erroneous--heuristics to do so.

  3. Phosphor-Free Solid State Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Nause, Jeff E; Ferguson, Ian; Doolittle, Alan

    2007-02-28

    The objective of this work was to demonstrate a light emitting diode that emitted white light without the aid of a phosphor. The device was based on the combination of a nitride LED and a fluorescing ZnO substrate. The early portion of the work focused on the growth of ZnO in undoped and doped form. The doped ZnO was successfully engineered to emit light at specific wavelengths by incorporating various dopants into the crystalline lattice. Thereafter, the focus of the work shifted to the epitaxial growth of nitride structures on ZnO. Initially, the epitaxy was accomplished with molecular beam epitaxy (MBE). Later in the program, metallorganic chemical vapor deposition (MOCVD) was successfully used to grow nitrides on ZnO. By combining the characteristics of the doped ZnO substrate with epitaxially grown nitride LED structures, a phosphor-free white light emitting diode was successfully demonstrated and characterized.

  4. Study on paper moisture measurement method by monochromatic light sources

    Science.gov (United States)

    Mo, Changtao; Du, Xin; He, Ping; Zhang, Lili; Li, Nan; Wang, Ming

    2010-10-01

    We design the emission and detection optical paths of three monochromatic infrared light sources with different wavelength. The three light sources are placed according to the different angles, so that the three kinds of monochromatic lights are converged on the same point of the sample. Using the method, we can detect the same point and improve the measurement accuracy. We choose the standard near-infrared monochromatic light source, so that we can save some equipments, such as tungsten- halogen lamp, filtered wheel, collimation focalizer, electric machine, and so on. In particular, we save the cumbersome cooling system, reduce the volume of the instrument greatly and reduce the cost. The three monochromatic light sources are supplied by the same pulse power source, to ensure their synchronous working.

  5. New results in atomic physics at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Schlachter, A.S.

    1995-01-01

    The Advanced Light Source is the world's first low-energy third-generation synchrotron radiation source. It has been running reliably and exceeding design specifications since it began operation in October 1993. It is available to a wide community of researchers in many scientific fields, including atomic and molecular science and chemistry. Here, new results in atomic physics at the Advanced Light Source demonstrate the opportunities available in atomic and molecular physics at this synchrotron light source. The unprecedented brightness allows experiments with high flux, high spectral resolution, and nearly 100% linear polarization.

  6. Development of implantable light source for optogenetics

    Science.gov (United States)

    Rusakov, Konstantin; Radzewicz, Czesław

    2016-09-01

    The research described here aims at a design and fabrication of a light emitting module for a mobile optogenetic device for animals that are freely moving in the IntelliCage system cages. The device is designed to stimulate selected brain areas of the animal with light. The approach described here is based on a LED chip attached to the tip of a cannula which will be directly implanted into a mouse's brain. The device has been fabricated and tested in a laboratory. In addition, we have observed optogenetic effect on the slice of mice brain tissue in vitro stimulated with our implants.

  7. A new storage-ring light source

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alex [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-06-01

    A recently proposed technique in storage ring accelerators is applied to provide potential high-power sources of photon radiation. The technique is based on the steady-state microbunching (SSMB) mechanism. As examples of this application, one may consider a high-power DUV photon source for research in atomic and molecular physics or a high-power EUV radiation source for industrial lithography. A less challenging proof-of-principle test to produce IR radiation using an existing storage ring is also considered.

  8. An experiment on the color rendering of different light sources

    Science.gov (United States)

    Fumagalli, Simonetta; Bonanomi, Cristian; Rizzi, Alessandro

    2013-02-01

    The color rendering index (CRI) of a light source attempts to measure how much the color appearance of objects is preserved when they are illuminated by the given light source. This problem is of great importance for various industrial and scientific fields, such as lighting architecture, design, ergonomics, etc. Usually a light source is specified through the Correlated Color Temperature or CCT. However two (or more) light sources with the same CCT but different spectral power distribution can exist. Therefore color samples viewed under two light sources with equal CCTs can appear different. Hence, the need for a method to assess the quality of a given illuminant in relation to color. Recently CRI has had a renewed interest because of the new LED-based lighting systems. They usually have a color rendering index rather low, but good preservation of color appearance and a pleasant visual appearance (visual appeal). Various attempts to develop a new color rendering index have been done so far, but still research is working for a better one. This article describes an experiment performed by human observers concerning the appearance preservation of color under some light sources, comparing it with a range of available color rendering indices.

  9. A numerical experiment on light pollution from distant sources

    Science.gov (United States)

    Kocifaj, M.

    2011-08-01

    To predict the light pollution of the night-time sky realistically over any location or measuring point on the ground presents quite a difficult calculation task. Light pollution of the local atmosphere is caused by stray light, light loss or reflection of artificially illuminated ground objects or surfaces such as streets, advertisement boards or building interiors. Thus it depends on the size, shape, spatial distribution, radiative pattern and spectral characteristics of many neighbouring light sources. The actual state of the atmospheric environment and the orography of the surrounding terrain are also relevant. All of these factors together influence the spectral sky radiance/luminance in a complex manner. Knowledge of the directional behaviour of light pollution is especially important for the correct interpretation of astronomical observations. From a mathematical point of view, the light noise or veil luminance of a specific sky element is given by a superposition of scattered light beams. Theoretical models that simulate light pollution typically take into account all ground-based light sources, thus imposing great requirements on CPU and MEM. As shown in this paper, a contribution of distant sources to the light pollution might be essential under specific conditions of low turbidity and/or Garstang-like radiative patterns. To evaluate the convergence of the theoretical model, numerical experiments are made for different light sources, spectral bands and atmospheric conditions. It is shown that in the worst case the integration limit is approximately 100 km, but it can be significantly shortened for light sources with cosine-like radiative patterns.

  10. NATIONAL SYNCHROTRON LIGHT SOURCE ACTIVITY REPORT 1998.

    Energy Technology Data Exchange (ETDEWEB)

    ROTHMAN,E.

    1999-05-01

    provided thereafter for half of the running time in FY 1998. In combination with the development of narrow gap undulators this mode opens the possibility of new undulators which could produce hard X-rays in the fundamental, perhaps up to 10 keV. On 27 September 1998, a low horizontal emittance lattice became operational at 2.584 GeV. This results in approximately a 50% decrease in the horizontal beam-size on dipole bending magnet beamlines, and somewhat less of a decrease on the insertion device lines. The beam lifetime is not degraded by the low emittance lattice. This represents an important achievement, enhancing for all users the x-ray ring brightness. The reduced horizontal emittance electron beam will produce brighter x-ray beams for all the beamlines, both bending magnets and insertion devices, adding to other recent increases in the X-Ray ring brightness. During FY 1999 users will gain experience of the new running mode and plans are in place to do the same at 2.8GeV during further studies sessions. Independent evidence of the reduced emittance is shown in Figure 2. This is a pinhole camera scan showing the X-ray beam profile, obtained on the diagnostic beamline X28. Finally, work has begun to update and refine the proposal of the Phase III upgrade endorsed by the Birgeneau panel and BESAC last year. With the whole NSLS facility in teenage years and with many demonstrated enhancements available, the time has come to herald in the next stage of life at the Light Source.

  11. Holographic free-electron light source

    Science.gov (United States)

    Li, Guanhai; Clarke, Brendan P.; So, Jin-Kyu; MacDonald, Kevin F.; Zheludev, Nikolay I.

    2016-12-01

    Recent advances in the physics and technology of light generation via free-electron proximity and impact interactions with nanostructures (gratings, photonic crystals, nano-undulators, metamaterials and antenna arrays) have enabled the development of nanoscale-resolution techniques for such applications as mapping plasmons, studying nanoparticle structural transformations and characterizing luminescent materials (including time-resolved measurements). Here, we introduce a universal approach allowing generation of light with prescribed wavelength, direction, divergence and topological charge via point-excitation of holographic plasmonic metasurfaces. It is illustrated using medium-energy free-electron injection to generate highly-directional visible to near-infrared light beams, at selected wavelengths in prescribed azimuthal and polar directions, with brightness two orders of magnitude higher than that from an unstructured surface, and vortex beams with topological charge up to ten. Such emitters, with micron-scale dimensions and the freedom to fully control radiation parameters, offer novel applications in nano-spectroscopy, nano-chemistry and sensing.

  12. Potential Sources of Polarized Light from a Plant Canopy

    Science.gov (United States)

    Vanderbilt, Vern; Daughtry, Craig; Dahlgren, Robert

    2016-01-01

    Field measurements have demonstrated that sunlight polarized during a first surface reflection by shiny leaves dominates the optical polarization of the light reflected by shiny-leafed plant canopies having approximately spherical leaf angle probability density functions ("Leaf Angle Distributions" - LAD). Yet for other canopies - specifically those without shiny leaves and/or spherical LADs - potential sources of optically polarized light may not always be obvious. Here we identify possible sources of polarized light within those other canopies and speculate on the ecologically important information polarization measurements of those sources might contain.

  13. The Nanohana 2 GeV Synchrotron light source

    CERN Document Server

    Korchuganov, V; Mezentsev, N A; Sajaev, Vadim; Takahashi, K; Aizawa, K; Kamiya, S; Oku, Y; Ohwaki, K

    2000-01-01

    Nanohana SR light source has been planned to be constructed in Chiba prefecture, Japan. The Nanohana is a synchrotron light source proposed for mainly industrial users. The electron storage ring has been designed to operate at injection energy of 500 MeV with a nominal energy of 2 GeV. The lattice is a Chasman-Green type with straight sections for up to six insertion devices. Several modes of operation are optimized to accommodate high-field superconducting wigglers, mini-pole undulators and VUV/SX undulators. Conceptual design of the synchrotron light source is presented.

  14. Synchronization System for Next Generation Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Zavriyev, Anton

    2014-03-27

    An alternative synchronization technique – one that would allow explicit control of the pulse train including its repetition rate and delay is clearly desired. We propose such a scheme. Our method is based on optical interferometry and permits synchronization of the pulse trains generated by two independent mode-locked lasers. As the next generation x-ray sources will be driven by a clock signal derived from a mode-locked optical source, our technique will provide a way to synchronize x-ray probe with the optical pump pulses.

  15. Comparative study of energy saving light sources

    Energy Technology Data Exchange (ETDEWEB)

    Khan, N.; Abas, N. [Department of Electrical Engineering, Comsats Institute of Information technology, Park Road, Islamabad (Pakistan)

    2011-01-15

    Techno-economic performance comparison of compact fluorescent lamps (CFL) with light emitting diodes (LED), electrode less fluorescent lamps (EEFL), fluorescent tubes, incandescent bulbs, photovoltaic (PV) and fiber optic lighting systems was carried out in view of worsening power and energy crisis in Pakistan. Literature survey showed 23 W CFL, 21 W EEFL, 18 W fluorescent tube or 15 W LED lamps emit almost same quantity of luminous flux (lumens) as a standard 100 W incandescent lamp. All inclusive, operational costs of LED lamps were found 1.21, 1.62. 1.69, 6.46, 19.90 and 21.04 times lesser than fluorescent tubes, CFL, EEFL, incandescent bulbs, fiber optic solar lighting and PV systems, respectively. However, tubes, LED, CFL and EEFL lamps worsen electric power quality of low voltage networks due to high current harmonic distortions (THD) and poor power factors (PF). Fluorescent lamps emit UV and pollute environment by mercury and phosphors when broken or at end of their life cycle. Energy consumption, bio-effects, and environmental concerns prefer LED lamps over phosphor based lamps but power quality considerations prefer EEFL. CFL and EEFL manufacturers claim operating temperatures in range of -20 C < T{sub CFL} < 60 C and -30 C < T{sub CFL} < 50 C but CFL frequently damage in wet and damp locations. Costs of low THD and high PF CFL, EEFL and LED lamps may be five to ten times higher that high THD and low PF lamps. Choice of a lamp depends upon its current THD, PF, life span, energy consumption, efficiency, efficacy, color rendering index (CRI) and associated physical effects. This work proposes manufacturing and user level innovations to get rid of low PF problems. Keeping in view downside of phosphor based lamps our research concludes widespread adoption of LED lamps. Government and commercial buildings may consider full spectrum hybrid thermal photovoltaic and solar fiber optic illumination systems. (author)

  16. Different light sources in photodynamic therapy for use in photorejuvenation

    CSIR Research Space (South Africa)

    Van Kets, V

    2010-09-01

    Full Text Available Photodynamic therapy (PDT) has recently emerged as a treatment modality for photorejuvenation of the skin. This study is a preliminary investigation into the effect of different light sources to activate hypericin, a plant-derived photosensitizer...

  17. Science and Technology of Future Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Dierker,S.; Bergmann, U.; Corlett, J.; Dierker, S.; Falcone, R.; Galayda, J.; Gibson, M.; Hastings, J.; Hettel, B.; Hill, J.; Hussain, Z.; Kao, C.-C.; Kirx, J.; Long, G.; McCurdy, B.; Raubenheimer, T.; Sannibale, F.; Seeman, J.; Shen, Z.-X.; Shenoy, g.; Schoenlein, B.; Shen, Q.; Stephenson, B.; Stohr, J.; Zholents, A.

    2008-12-01

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects. The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of

  18. Science and Technology of Future Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, Uwe; Corlett, John; Dierker, Steve; Falcone, Roger; Galayda, John; Gibson, Murray; Hastings, Jerry; Hettel, Bob; Hill, John; Hussain, Zahid; Kao, Chi-Chang; Kirz, Janos; Long, Danielle; McCurdy, Bill; Raubenheimer, Tor; Sannibale, Fernando; Seeman, John; Shen, Z. -X.; Schenoy, Gopal; Schoenlein, Bob; Shen, Qun; Stephenson, Brian; Stohr, Joachim; Zholents, Alexander

    2009-01-28

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of

  19. Performance of single mechanoluminescent particle as ubiquitous light source.

    Science.gov (United States)

    Terasaki, Nao; Xu, Chao-Nan

    2014-08-01

    In this study, we have investigated mechanoluminescent (ML) performance of single ML particle as ubiquitous light source. When using high-speed CCD camera with image intensifier and microscopic equipment, mechanoluminescence from single particle was observed. As to the quantitative ML evaluation of the single ML particle was carried out using photomultiplier, and successfully estimated the performance of the single ML particle as an intensity controllable light source in nW order.

  20. A new LED light source for display cases

    DEFF Research Database (Denmark)

    Dam-Hansen, Carsten; Petersen, Paul Michael

    Abstract: We report a new LED light source suitable for illumination of gold objects. It has a variable correlated color temperature from 2760 K to 2200 K with a high color rendering index up to 97.......Abstract: We report a new LED light source suitable for illumination of gold objects. It has a variable correlated color temperature from 2760 K to 2200 K with a high color rendering index up to 97....

  1. Modification of light sources for appropriate biological action

    Energy Technology Data Exchange (ETDEWEB)

    Kozakov, R; Schoepp, H; Franke, St [Leibniz Institute of Plasma Science and Technology, Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany); Stoll, C; Kunz, D, E-mail: kozakov@inp-greifswald.d [Charite-Universitymedicine Berlin, Sleep Research and Clinical Chronobiology, Gr. Hamburger Str. 5-11, D-10115 Berlin (Germany)

    2010-06-16

    The impact of the non-visual action of light on the design of novel light sources is discussed. Therefore possible modifications of lamps dealing with spectral tailoring and their action on melatonin suppression in usual life situations are investigated. The results of melatonin suppression by plasma lamps are presented. It is shown that even short-time exposure to usual light levels in working areas has an influence on the melatonin onset.

  2. Visible and ultraviolet light sources based nonlinear interaction of lasers

    DEFF Research Database (Denmark)

    Andersen, Martin Thalbitzer; Tidemand-Lichtenberg, Peter; Jain, Mayank;

    Different light sources can be used for optically stimulated luminescence measurements and usually a halogen lamp in combination with filters or light emitting diodes (LED’s) are used to provide the desired stimulation wavelength. However lasers can provide a much more well-defined beam, very...

  3. Advanced light source, User`s Handbook, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Advanced Light Source (ALS) is a national facility for scientific research and development located at the Lawrence Berkeley National Laboratory (LBNL) of the University of California. Its purpose is to generate beams of very bright light in the ultraviolet and soft x-ray regions of the spectrum. The facility is open to researchers from industry, universities, and government laboratories.

  4. Hyperspectral microscopy to identify foodborne bacteria with optimum lighting source

    Science.gov (United States)

    Hyperspectral microscopy is an emerging technology for rapid detection of foodborne pathogenic bacteria. Since scattering spectral signatures from hyperspectral microscopic images (HMI) vary with lighting sources, it is important to select optimal lights. The objective of this study is to compare t...

  5. Coherent broadband light source for parallel optical coherence tomography

    NARCIS (Netherlands)

    Rivier, S.; Laversenne, L.; Bourquin, S.; Salathé, R.P.; Pollnau, M.; Grivas, C.; Shepherd, D.P.; Eason, R.W.; Flury, M.; Philipoussis, I.; Herzig, H.P.

    2004-01-01

    A Ti:sapphire planar waveguide is rib structured by Ar ion milling to provide parallel channel waveguides. By coupling high-power pump light through a microlens array into the waveguides, a novel broadband luminescent parallel emitter is demonstrated as a light source for parallel optical coherence

  6. Compact synchrotron light source of the HSRC.

    Science.gov (United States)

    Yoshida, K; Takayama, T; Hori, T

    1998-05-01

    A 700 MeV synchrotron radiation source optimized in order to be incorporated in the university laboratory is under commissioning at Hiroshima University. The storage ring is of a racetrack type with two long straight sections for installing undulators. The bending field is as strong as 2.7 T, produced by normal-conducting magnet technology, and delivers synchrotron radiation with a critical wavelength of 1.42 nm. The strong magnetic field also enables a low-energy injection scheme to be employed owing to the fast radiation damping. A 150 MeV microtron has been adopted as the injector.

  7. Polarized light source based on graphene-nanoribbon hybrid structure

    Science.gov (United States)

    Xu, Pengfei; Zhang, Han; Qian, Haoliang; Chen, Bigeng; Jiang, Xiaoshun; Wu, Yuanpeng; Liu, Xiaowei; Liu, Xu; Yang, Qing

    2017-07-01

    Nanoscale light source is the key element for on-chip integrated optical communication system. As an important property of light source, polarization can be exploited to improve the information capacity of optical communication and the sensitivity of optical sensing. We demonstrate a novel TE-polarized light source based on graphene-nanoribbon (G-NR) hybrid structure. Thanks to the polarizing dependent absorption along graphene layer, the random polarized emission of nanoribbon (NR) can be transferred into the same TE polarization. In addition, lasing action in G-NR hybrid structure is also investigated. We attribute the polarization control to the differential attenuation of electromagnetic modes in graphene. Our simulation revealed electromagnetic field distribution and far field polar images of TE and TM modes in nanoribbon, which is consistent with experimental results. The compact G-NR hybrid structure light source offers a new way to realize the polarization controllable nanoscale light source and facilitate the practical applications of nanowire or nanoribbon light source.

  8. National Synchrotron Light Source annual report 1991

    Energy Technology Data Exchange (ETDEWEB)

    Hulbert, S.L.; Lazarz, N.M. (eds.)

    1992-04-01

    This report discusses the following research conducted at NSLS: atomic and molecular science; energy dispersive diffraction; lithography, microscopy and tomography; nuclear physics; UV photoemission and surface science; x-ray absorption spectroscopy; x-ray scattering and crystallography; x-ray topography; workshop on surface structure; workshop on electronic and chemical phenomena at surfaces; workshop on imaging; UV FEL machine reviews; VUV machine operations; VUV beamline operations; VUV storage ring parameters; x-ray machine operations; x-ray beamline operations; x-ray storage ring parameters; superconducting x-ray lithography source; SXLS storage ring parameters; the accelerator test facility; proposed UV-FEL user facility at the NSLS; global orbit feedback systems; and NSLS computer system.

  9. Control and Driving Methods for LED Based Intelligent Light Sources

    DEFF Research Database (Denmark)

    Beczkowski, Szymon

    High power light-emitting diodes allow the creation of luminaires capable of generating saturated colour light at very high efficacies. Contrary to traditional light sources like incandescent and high-intensity discharge lamps, where colour is generated using filters, LEDs use additive light mixing......, where the intensity of each primary colour diode has to be adjusted to the needed intensity to generate specified colour. The function of LED driver is to supply the diode with power needed to achieve the desired intensity. Typically, the drivers operate as a current source and the intensity...... current. The model can also be used to create highly accurate luminaire model. Finally, a dual interleaved buck converter has been proposed for driving high power light-emitting diodes. Interleaving two converters lowers the output ripple current thus lowering the requirement on the output capacitor...

  10. Visible light scatter as quantitative information source on milk constituents

    DEFF Research Database (Denmark)

    Melentieva, Anastasiya; Kucheryavskiy, Sergey; Bogomolov, Andrey

    2012-01-01

    -time monitoring of processes and products. Optical analysis is generally performed in near and middle infrared (NIR and MIR) regions and relies on the component absorbance and Beer’s Law. The light scatter effect is therefore considered as a disturbance to be avoided during the measurement or eliminated...... at the data analysis stage. The region of visible (Vis) light (400-800 nm) is economically attractive, because it offers a range of inexpensive light sources, optics and detectors. At present, however, it is commonly considered useless, because of the light scatter by fat globules (1-10 μm) and protein...

  11. The Materials Science beamline upgrade at the Swiss Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Willmott, P. R., E-mail: philip.willmott@psi.ch; Meister, D.; Leake, S. J.; Lange, M.; Bergamaschi, A. [Swiss Light Source, Paul Scherrer Institut, CH-5232 Villigen (Switzerland); and others

    2013-07-16

    The wiggler X-ray source of the Materials Science beamline at the Swiss Light Source has been replaced with a 14 mm-period cryogenically cooled in-vacuum undulator. In order to best exploit the increased brilliance of this new source, the entire front-end and optics have been redesigned. The Materials Science beamline at the Swiss Light Source has been operational since 2001. In late 2010, the original wiggler source was replaced with a novel insertion device, which allows unprecedented access to high photon energies from an undulator installed in a medium-energy storage ring. In order to best exploit the increased brilliance of this new source, the entire front-end and optics had to be redesigned. In this work, the upgrade of the beamline is described in detail. The tone is didactic, from which it is hoped the reader can adapt the concepts and ideas to his or her needs.

  12. Light Source Matters--Students' Explanations about the Behavior of Light When Different Light Sources Are Used in Task Assignments of Optics

    Science.gov (United States)

    Kesonen, Mikko Henri Petteri; Asikainen, Mervi Anita; Hirvonen, Pekka Emil

    2017-01-01

    In the present article, the context-dependency of student reasoning is studied in a context of optics. We investigated introductory students' explanations about the behavior of light when different light sources, namely a small light bulb and a laser, were used in otherwise identical task assignments. The data was gathered with the aid of pretest…

  13. The Munich Compact Light Source: initial performance measures.

    Science.gov (United States)

    Eggl, Elena; Dierolf, Martin; Achterhold, Klaus; Jud, Christoph; Günther, Benedikt; Braig, Eva; Gleich, Bernhard; Pfeiffer, Franz

    2016-09-01

    While large-scale synchrotron sources provide a highly brilliant monochromatic X-ray beam, these X-ray sources are expensive in terms of installation and maintenance, and require large amounts of space due to the size of storage rings for GeV electrons. On the other hand, laboratory X-ray tube sources can easily be implemented in laboratories or hospitals with comparatively little cost, but their performance features a lower brilliance and a polychromatic spectrum creates problems with beam hardening artifacts for imaging experiments. Over the last decade, compact synchrotron sources based on inverse Compton scattering have evolved as one of the most promising types of laboratory-scale X-ray sources: they provide a performance and brilliance that lie in between those of large-scale synchrotron sources and X-ray tube sources, with significantly reduced financial and spatial requirements. These sources produce X-rays through the collision of relativistic electrons with infrared laser photons. In this study, an analysis of the performance, such as X-ray flux, source size and spectra, of the first commercially sold compact light source, the Munich Compact Light Source, is presented.

  14. Suboptimal light conditions influence source-sink metabolism during flowering

    Directory of Open Access Journals (Sweden)

    Annelies eChristiaens

    2016-03-01

    Full Text Available Reliance on carbohydrates during flower forcing was investigated in one early and one late flowering cultivar of azalea (Rhododendron simsii hybrids. Carbohydrate accumulation, invertase activity, and expression of a purported sucrose synthase gene (RsSUS was monitored during flower forcing under suboptimal (natural and optimal (supplemental light light conditions, after a cold treatment (7°C + dark to break flower bud dormancy. Post-production sucrose metabolism and flowering quality was also assessed. Glucose and fructose concentrations and invertase activity increased in petals during flowering, while sucrose decreased. In suboptimal light conditions RsSUS expression in leaves increased as compared to optimal light conditions, indicating that plants in suboptimal light conditions have a strong demand for carbohydrates. However, carbohydrates in leaves were markedly lower in suboptimal light conditions compared to optimal light conditions. This resulted in poor flowering of plants in suboptimal light conditions. Post-production flowering relied on the stored leaf carbon, which could be accumulated under optimal light conditions in the greenhouse. These results show that flower opening in azalea relies on carbohydrates imported from leaves and is source-limiting under suboptimal light conditions.

  15. Powerful nanosecond light sources based on LEDs for astroparticle physics experiments

    OpenAIRE

    Lubsandorzhiev, B. K.; Poleshuk, R. V.; Shaibonov, B. A. J.; Vyatchin, Y. E.

    2007-01-01

    Powerful nanosecond light sources based on LEDs have been developed for use in astroparticle physics experiments. The light sources use either matrixes of ultra bright blue LEDs or a new generation high power blue LEDs. It's shown that such light sources have light yield of up to 10**10 - 10**12 photons per pulse with very fast light emission kinetics. The described light sources are important for use in calibration systems of Cherenkov and scintillator detectors. The developed light sources ...

  16. Increased collection efficiency of LIFI high intensity electrodeless light source

    Science.gov (United States)

    Hafidi, Abdeslam; DeVincentis, Marc; Duelli, Markus; Gilliard, Richard

    2008-02-01

    Recently, RF driven electrodeless high intensity light sources have been implemented successfully in the projection display systems for HDTV and videowall applications. This paper presents advances made in the RF waveguide and electric field concentrator structures with the purpose of reducing effective arc size and increasing light collection. In addition, new optical designs are described that further improve system efficiency. The results of this work demonstrate that projection system light throughput is increased relative to previous implementations and performance is optimized for home theater and other front projector applications that maintain multi-year lifetime without re-lamping, complete spectral range, fast start times and high levels of dynamic contrast due to dimming flexibility in the light source system.

  17. Electrodeless lighting RF power source development. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-30

    An efficient, solid state RF power source has been developed on this NICE project for exciting low power electrodeless lamp bulbs. This project takes full advantage of concurrent advances in electrodeless lamp technology. Electrodeless lamp lighting systems utilizing the sulfur based bulb type developed by Fusion Lighting, Inc., is an emerging technology which is based on generating light in a confined plasma created and sustained by RF excitation. The bulb for such a lamp is filled with a particular element and inert gas at low pressure when cold. RF power from the RF source creates a plasma within the bulb which reaches temperatures approaching those of high pressure discharge lamp plasmas. At these temperatures the plasma radiates substantial visible light with a spectrum similar to sunlight.

  18. Tunable light source for use in photoacoustic spectrometers

    Science.gov (United States)

    Bisson, Scott E.; Kulp, Thomas J.; Armstrong, Karla M.

    2005-12-13

    The present invention provides a photoacoustic spectrometer that is field portable and capable of speciating complex organic molecules in the gas phase. The spectrometer has a tunable light source that has the ability to resolve the fine structure of these molecules over a large wavelength range. The inventive light source includes an optical parametric oscillator (OPO) having combined fine and coarse tuning. By pumping the OPO with the output from a doped-fiber optical amplifier pumped by a diode seed laser, the inventive spectrometer is able to speciate mixtures having parts per billion of organic compounds, with a light source that has a high efficiency and small size, allowing for portability. In an alternative embodiment, the spectrometer is scanned by controlling the laser wavelength, thus resulting in an even more compact and efficient design.

  19. Solid state light source driver establishing buck or boost operation

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, Fred

    2017-08-29

    A solid state light source driver circuit that operates in either a buck convertor or a boost convertor configuration is provided. The driver circuit includes a controller, a boost switch circuit and a buck switch circuit, each coupled to the controller, and a feedback circuit, coupled to the light source. The feedback circuit provides feedback to the controller, representing a DC output of the driver circuit. The controller controls the boost switch circuit and the buck switch circuit in response to the feedback signal, to regulate current to the light source. The controller places the driver circuit in its boost converter configuration when the DC output is less than a rectified AC voltage coupled to the driver circuit at an input node. The controller places the driver circuit in its buck converter configuration when the DC output is greater than the rectified AC voltage at the input node.

  20. Does the light source affect the repairability of composite resins?

    Directory of Open Access Journals (Sweden)

    Emel KARAMAN

    2014-08-01

    Full Text Available The aim of this study was to examine the effect of the light source on the microshear bond strength of different composite resins repaired with the same substrate. Thirty cylindrical specimens of each composite resin—Filtek Silorane, Filtek Z550 (3M ESPE, Gradia Direct Anterior (GC, and Aelite Posterior (BISCO—were prepared and light-cured with a QTH light curing unit (LCU. The specimens were aged by thermal cycling and divided into three subgroups according to the light source used—QTH, LED, or PAC (n = 10. They were repaired with the same substrate and a Clearfil Repair Kit (Kuraray. The specimens were light-cured and aged for 1 week in distilled water at 37 °C. The microshear bond strength and failure modes were assessed. There was no significant difference in the microshear bond strength values among the composite resins, except for the Filtek Silorane group that showed significantly lower bond strength values when polymerized with the PAC unit compared to the QTH or LED unit. In conclusion, previously placed dimethacrylate-based composites can be repaired with different light sources; however, if the composite to be repaired is silorane-based, then using a QTH or LED device may be the best option.

  1. The Advanced Light Source (ALS) Radiation Safety System. Revised

    Energy Technology Data Exchange (ETDEWEB)

    Ritchie, A.L.; Oldfather, D.E.; Lindner, A.F.

    1993-08-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory (LBL) is a 1.5 Gev synchrotron light source facility consisting of a 120 kev electron gun, 50 Mev linear accelerator, 1.5 Gev booster synchrotron, 200 meter circumference electron storage ring, and many photon beamline transport systems for research. Figure 1. ALS floor plan. Pairs of neutron and gamma radiation monitors are shown as dots numbered from 1 to 12. The Radiation Safety System for the ALS has been designed and built with a primary goal of providing protection against inadvertent personnel exposure to gamma and neutron radiation and, secondarily, to enhance the electrical safety of select magnet power supplies.

  2. Ultrahigh resolution optical coherence tomography using a superluminescent light source.

    Science.gov (United States)

    Kowalevicz, Andrew; Ko, Tony; Hartl, Ingmar; Fujimoto, James; Pollnau, Markus; Salathé, René

    2002-04-08

    A superluminescent Ti:Al2O(3) crystal is demonstrated as a light source for ultrahigh resolution optical coherence tomography (OCT). Single spatial mode, fiber coupled output powers of ~40 microW can be generated with 138 nm bandwidth using a 5 W frequency doubled, diode pumped laser, pumping a thin Ti:Al2O(3) crystal. Ultrahigh resolution OCT imaging is demonstrated with 2.2 microm axial resolution in air, or 1.7 microm in tissue, with >86 dB sensitivity. This light source provides a simple and robust alternative to femtosecond lasers for ultrahigh resolution OCT imaging.

  3. Survey and alignment for the Swiss Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Wei, F.Q.; Dreyer, K.; Fehlmann, U.; Pochon, J.L.; Wrulich, A. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-07-01

    The Swiss Light Source (SLS) is a dedicated high brightness synchrotron light source currently under construction at the Paul Scherrer Institute (PSI) in Villigen. It will be commissioned in 2001. The accelerator complex includes a 2.4 GeV electron storage ring (SR) with 288 in circumference, a full energy injection booster synchrotron (Booster) and a 100 MeV linear pre-accelerator. The general alignment method and first results of the network measurements are presented. A laser tracker LTD500 is mainly adopted for network measurements and the alignment of storage ring components. (authors)

  4. Generating polarization controllable FELs at Dalian coherent light source

    CERN Document Server

    Zhang, T; Wang, D; Zhao, Z T; Zhang, W Q; Wu, G R; Dai, D X; Yang, X M

    2013-01-01

    The property of the FEL polarization is of great importance to the user community. FEL pulses with ultra-high intensity and flexible polarization control ability will absolutely open up new scientific realms. In this paper, several polarization control approaches are presented to investigate the great potential on Dalian coherent light source, which is a government-approved novel FEL user facility with the capability of wavelength continuously tunable in the EUV regime of 50-150 nm. The numerical simulations show that both circularly polarized FELs with highly modulating frequency and 100 microjoule level pulse energy could be generated at Dalian coherent light source.

  5. Laser wakefield accelerator based light sources: potential applications and requirements

    Energy Technology Data Exchange (ETDEWEB)

    Albert, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). NIF and Photon Sciences; Thomas, A. G. [Univ. of Michigan, Ann Arbor, MI (United States). Dept. of Nuclear Engineering and Radiological Sciences; Mangles, S. P.D. [Imperial College, London (United Kingdom). Blackett Lab.; Banerjee, S. [Univ. of Nebraska, Lincoln, NE (United States); Corde, S. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Flacco, A. [ENSTA, CNRS, Ecole Polytechnique, Palaiseau (France); Litos, M. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Neely, D. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Viera, J. [Univ. of Lisbon (Portugal). GoLP-Inst. de Plasmas e Fusao Nuclear-Lab. Associado; Najmudin, Z. [Imperial College, London (United Kingdom). Blackett Lab.; Bingham, R. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Joshi, C. [Univ. of California, Los Angeles, CA (United States). Dept. of Electrical Engineering; Katsouleas, T. [Duke Univ., Durham, NC (United States). Platt School of Engineering

    2015-01-15

    In this article we review the prospects of laser wakefield accelerators as next generation light sources for applications. This work arose as a result of discussions held at the 2013 Laser Plasma Accelerators Workshop. X-ray phase contrast imaging, X-ray absorption spectroscopy, and nuclear resonance fluorescence are highlighted as potential applications for laser-plasma based light sources. We discuss ongoing and future efforts to improve the properties of radiation from plasma betatron emission and Compton scattering using laser wakefield accelerators for these specific applications.

  6. Synchrotron radiation as a light source in confocal microscopy

    Energy Technology Data Exchange (ETDEWEB)

    van der Oord, C.J.R.; Gerritsen, H.C.; Levine, Y.K. (University of Utrecht, P.O. Box 80.000, 3508 TA Utrecht (Netherlands)); Myring, W.J.; Jones, G.R.; Munro, I.H. (Daresbury Laboratory (United Kingdom))

    1992-01-01

    The optical properties of a confocal scanning microscope that was designed to utilize a synchrotron as light source are presented. The usable spectral range is from 200 nm up to 700 nm. Using 325-nm laser light, it is shown that the lateral resolution is about 125 nm, and the axial resolution better than 250 nm. After transport of the microscope from Utrecht to the Daresbury Synchrotron Source, 200-nm excitation can be applied, and the lateral resolution will drop to below 100 nm.

  7. Applications of laser wakefield accelerator-based light sources

    Science.gov (United States)

    Albert, Félicie; Thomas, Alec G. R.

    2016-11-01

    Laser-wakefield accelerators (LWFAs) were proposed more than three decades ago, and while they promise to deliver compact, high energy particle accelerators, they will also provide the scientific community with novel light sources. In a LWFA, where an intense laser pulse focused onto a plasma forms an electromagnetic wave in its wake, electrons can be trapped and are now routinely accelerated to GeV energies. From terahertz radiation to gamma-rays, this article reviews light sources from relativistic electrons produced by LWFAs, and discusses their potential applications. Betatron motion, Compton scattering and undulators respectively produce x-rays or gamma-rays by oscillating relativistic electrons in the wakefield behind the laser pulse, a counter-propagating laser field, or a magnetic undulator. Other LWFA-based light sources include bremsstrahlung and terahertz radiation. We first evaluate the performance of each of these light sources, and compare them with more conventional approaches, including radio frequency accelerators or other laser-driven sources. We have then identified applications, which we discuss in details, in a broad range of fields: medical and biological applications, military, defense and industrial applications, and condensed matter and high energy density science.

  8. High efficiency light source using solid-state emitter and down-conversion material

    Science.gov (United States)

    Narendran, Nadarajah; Gu, Yimin; Freyssinier, Jean Paul

    2010-10-26

    A light emitting apparatus includes a source of light for emitting light; a down conversion material receiving the emitted light, and converting the emitted light into transmitted light and backward transmitted light; and an optic device configured to receive the backward transmitted light and transfer the backward transmitted light outside of the optic device. The source of light is a semiconductor light emitting diode, a laser diode (LD), or a resonant cavity light emitting diode (RCLED). The down conversion material includes one of phosphor or other material for absorbing light in one spectral region and emitting light in another spectral region. The optic device, or lens, includes light transmissive material.

  9. Seeing "the Dress" in the Right Light: Perceived Colors and Inferred Light Sources.

    Science.gov (United States)

    Chetverikov, Andrey; Ivanchei, Ivan

    2016-08-01

    In the well-known "dress" photograph, people either see the dress as blue with black stripes or as white with golden stripes. We suggest that the perception of colors is guided by the scene interpretation and the inferred positions of light sources. We tested this hypothesis in two online studies using color matching to estimate the colors observers see, while controlling for individual differences in gray point bias and color discrimination. Study 1 demonstrates that the interpretation of the dress corresponds to differences in perceived colors. Moreover, people who perceive the dress as blue-and-black are two times more likely to consider the light source as frontal, than those who see the white-and-gold dress. The inferred light sources, in turn, depend on the circadian changes in ambient light. The interpretation of the scene background as a wall or a mirror is consistent with the perceived colors as well. Study 2 shows that matching provides reliable results on differing devices and replicates the findings on scene interpretation and light sources. Additionally, we show that participants' environmental lighting conditions are an important cue for perceiving the dress colors. The exact mechanisms of how environmental lighting and circadian changes influence the perceived colors of the dress deserve further investigation.

  10. Determining and quantifying specific sources of light alkane

    Science.gov (United States)

    Bill, M.; Conrad, M. E.

    2015-12-01

    Determining and quantifying specific sources of emission of methane (an important greenhouse gas) and light alkanes from abandoned gas and oil wells, hydraulic fracturing or associated with CO2 sequestration are a challenge in determining their contribution to the atmospheric greenhouse gas budget or to identify source of groundwater contamination. Here, we review organic biogeochemistry proprieties and isotopic fingerprinting of C1-C5 alkanes to address this problem. For instance, the concentration ratios of CH4 to C2-C5 alkanes can be used to distinguish between thermogenic and microbial generated CH4. Together C and H isotopes of CH4 are used to differentiate bacterial generated sources and thermogenic CH4 and may also identify processes such as alteration and source mixing. Carbon isotope ratios pattern of C1-C5 alkanes highlight sources and oxidation processes in the gas reservoirs. Stable carbon isotope measurements are a viable tool for monitoring the degradation progress of methane and light hydrocarbons. The carbon isotope ratios of the reactants and products are independent of the concentration and only depend on the relative progress of the particular reaction. Oxidation/degradation of light alkanes are typically associated with increasing ð13C values. Isotopic mass balances offer the possibility to independently determine the fractions coming from microbial versus thermogenic and would also permit differentiation of the isotope fractionations associated with degradation. Unlike conventional concentration measurements, this approach is constrained by the different isotopic signatures of various sources and sinks.

  11. Correlated Color Temperature Tunable Multi-chip Light Emitting Diodes Light Source Design

    Institute of Scientific and Technical Information of China (English)

    SHEN Hai-ping; PAN Jian-gen; FENG Hua-jun

    2008-01-01

    One of the methods to derive white light from light emitting diodes(LEDs) is the multi-chip white LED technology, which mixes the light from red, green and blue LEDs. Introduced is an optimal algorithm for the spectrum design of the multi-chip white LEDs in this paper. It optimizes the selection of single color LEDs and drive current controlling, so that the multi-chip white LED achieves the target correlated color temperature(CCT), as well as high luminous efficacy and good color rendering. A CCT tunable LED light source with four high-power LEDs is realized based on the above optimal design. Test results show that it maintains satisfactory color rendering and stable luminous efficacy across the whole CCT tuning range. Finally, discussed are the design improvement and the prospect of the future applications of the CCT tunable LED light source.

  12. Statistical evaluation of alternative light sources for bloodstain photography.

    Science.gov (United States)

    Lee, Wee Chuen; Khoo, Bee Ee; Bin Abdullah, Ahmad Fahmi Lim; Abdul Aziz, Zalina Binti

    2013-05-01

    Bloodstain photography is important in forensic applications, especially for bloodstain pattern analysis. This study compares the enhancement effect of bloodstain photography using three different types of light source: fluorescent white light, near-ultraviolet (UV) light-emitting diode (LED) light, and 410 nm LED light. Randomized complete block designs were implemented to identify the lighting that would statistically produce the best enhancement results for bloodstains on different types of surfaces. Bloodstain samples were prepared on white cotton, brown carpet, tar road, and wood. These samples were photographed in darkroom conditions using a Canon EOS 50D digital SLR camera, with Canon EFS 60 mm f/2.8 Macro USM lens. Two-way analysis of variance and Fisher's least significant difference test were used to analyze the contrast of the images. The statistical analysis showed that 410 nm light is the best among the tested lights for enhancing bloodstains on the tested surfaces, where the contrast of bloodstain to background was the highest.

  13. Retinal endoilluminator toxicity of xenon and light-emitting diode (LED) light source: rabbit model.

    Science.gov (United States)

    Aydin, Bahri; Dinç, Erdem; Yilmaz, S Necat; Altiparmak, U Emrah; Yülek, Fatma; Ertekin, Sevda; Yilmaz, Mustafa; Yakın, Mehmet

    2014-09-01

    This study evaluates retinal toxicity due to endoillumination with the light-emitting diode (LED) light source in comparison to endoillumination with xenon light source. Twenty-five eyes of 14 New Zealand pigmented rabbits were used in the study. The LED light (Omesis Medical Systems, Turkey) group was composed of 7 right eyes, while the other 7 right eyes constituted the xenon group (420 nm filter, 357mW/cm(2)) (Bright Star; DORC, Zuidland, Netherlands). Eleven untreated left eyes composed the control group. Twenty gauge pars plana incision 1.5 mm behind the limbus was performed in the right eyes. Twenty gauge bullet type fiberoptic endoilluminator was inserted into the eye from the incision without any pars plana vitrectomy. Fiberoptic endoilluminator was placed in such a way that it was directed toward visual streak of the rabbit retina with a 5 mm distance to retinal surface. Endoillumination was then applied for 20 min with a maximum light intensity for LED and xenon light. In left control eyes, no surgical procedure and no endoillumination were performed. One week after the endoillumination procedure, both eyes of the rabbits were enucleated following electroretinography. Sections stained with hematoxylin and eosin to evaluate morphologic changes. Retina tissues were assessed by active caspase-3 staining. There was no difference in the shape of the waveforms recorded in the eyes endoilluminated with LED light and xenon light sources compared to control eyes both before and after endoillumination application (p > 0.05). Microscopic evaluation of the retinas with hematoxylin and eosin staining demonstrated that all study groups have normal histologic properties similar to control group. No apoptosis positive cells were found within all sections in all groups. When the LED light source is used with maximum power and limited duration for endoillumination in rabbit eyes it does not produce phototoxic effects that may be detectable by electrophysiology

  14. PREFACE: Diagnostics for electrical discharge light sources: pushing the limits Diagnostics for electrical discharge light sources: pushing the limits

    Science.gov (United States)

    Zissis, Georges; Haverlag, Marco

    2010-06-01

    Light sources play an indispensable role in the daily life of any human being. Quality of life, health and urban security related to traffic and crime prevention depend on light and on its quality. In fact, every day approximately 30 billion electric light sources operate worldwide. These electric light sources consume almost 19% of worldwide electricity production. Finding new ways to light lamps is a challenge where the stakes are scientific, technological, economic and environmental. The production of more efficient light sources is a sustainable solution for humanity. There are many opportunities for not only enhancing the efficiency and reliability of lighting systems but also for improving the quality of light as seen by the end user. This is possible through intelligent use of new technologies, deep scientific understanding of the operating principles of light sources and knowledge of the varied human requirements for different types of lighting in different settings. A revolution in the domain of light source technology is on the way: high brightness light emitting diodes arriving in the general lighting market, together with organic LEDs (OLEDs), are producing spectacular advances. However, unlike incandescence, electrical discharge lamps are far from disappearing from the market. In addition, new generations of discharge lamps based on molecular radiators are becoming a reality. There are still many scientific and technological challenges to be raised in this direction. Diagnostics are important for understanding the fundamental mechanisms taking place in the discharge plasma. This understanding is an absolute necessity for system optimization leading to more efficient and high quality light sources. The studied medium is rather complex, but new diagnostic techniques coupled to innovative ideas and powerful tools have been developed in recent years. This cluster issue of seven papers illustrates these efforts. The selected papers cover all domains, from

  15. The effect of light-activation sources on tooth bleaching

    Directory of Open Access Journals (Sweden)

    Kusai Baroudi

    2014-01-01

    Full Text Available Vital bleaching is one of the most requested cosmetic dental procedures asked by patients who seek a more pleasing smile. This procedure consists of carbamide or hydrogen peroxide gel applications that can be applied in-office or by the patient (at-home/overnight bleaching system. Some in-office treatments utilise whitening light with the objective of speeding up the whitening process. The objective of this article is to review and summarise the current literature with regard to the effect of light-activation sources on in-office tooth bleaching. A literature search was conducted using Medline, accessed via the National Library of Medicine Pub Med from 2003 to 2013 searching for articles relating to effectiveness of light activation sources on in-office tooth bleaching. This study found conflicting evidence on whether light truly improve tooth whitening. Other factors such as, type of stain, initial tooth colour and subject age which can influence tooth bleaching outcome were discussed. Conclusions: The use of light activator sources with in-office bleaching treatment of vital teeth did not increase the efficacy of bleaching or accelerate the bleaching.

  16. VCSELs and silicon light sources exploiting SOI grating mirrors

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper

    2012-01-01

    In this talk, novel vertical-cavity laser structure consisting of a dielectric Bragg reflector, a III-V active region, and a high-index-contrast grating made in the Si layer of a silicon-on-insulator (SOI) wafer will be presented. In the Si light source version of this laser structure, the SOI gr...

  17. Advanced Light Source Activity Report 1997/1998

    Energy Technology Data Exchange (ETDEWEB)

    Greiner, Annette (ed.)

    1999-03-01

    This Lawrence Berkeley National Laboratory, Advanced Light Source (ALS) activity report for 1997/98 discusses the following topics: Introduction and Overview; Science Highlights; Facility Report; Special Events; ALS Advisory Panels 1997/98; ALS Staff 1997/98 and Facts and Figures for the year.

  18. Ultrahigh resolution optical coherence tomography using a superluminescent light source

    NARCIS (Netherlands)

    Kowalevicz, Andrew M.; Ko, Tony; Hartl, Ingmar; Fujimoto, James G.; Pollnau, Markus; Salathé, René P.

    2002-01-01

    A superluminescent Ti:Al2O3 crystal is demonstrated as a light source for ultrahigh resolution optical coherence tomography (OCT). Single spatial mode, fiber coupled output powers of ~40 μW can be generated with 138 nm bandwidth using a 5 W frequency doubled, diode pumped laser, pumping a thin Ti:Al

  19. Rare-earth plasma light source for VUV applications.

    Science.gov (United States)

    O'Sullivan, G; Carroll, P K; McLlrath, T J; Ginter, M L

    1981-09-01

    A compact versatile light source for producing VUV radiation from laser produced plasmas is described. Measurements of the spectral irradiance from CO(2) laser-produced plasmas on targets of gadolinium and ytterbium in the 115-220-nm range are given, and a comparison is made with analogous results obtained using a ruby laser.

  20. Enabling instrumentation and technology for 21st century light sources

    Energy Technology Data Exchange (ETDEWEB)

    Byrd, J.M.; Shea, T.J.; Denes, P.; Siddons, P.; Attwood, D.; Kaertner, F.; Moog, L.; Li, Y.; Sakdinawat, A.; Schlueter, R.

    2010-06-01

    We present the summary from the Accelerator Instrumentation and Technology working group, one of the five working groups that participated in the BES-sponsored Workshop on Accelerator Physics of Future Light Sources held in Gaithersburg, MD September 15-17, 2009. We describe progress and potential in three areas: attosecond instrumentation, photon detectors for user experiments, and insertion devices.

  1. Compact X-ray Light Source Workshop Report

    Energy Technology Data Exchange (ETDEWEB)

    Thevuthasan, Suntharampillai; Evans, James E.; Terminello, Louis J.; Koppenaal, David W.; Manke, Kristin L.; Plata, Charity

    2012-12-01

    This report, produced jointly by EMSL and FCSD, is the result of a workshop held in September 2011 that examined the utility of a compact x-ray light source (CXLS) in addressing many scientific challenges critical to advancing energy science and technology.

  2. The Pre-Injector Linac for the Diamond Light Source

    CERN Document Server

    Christou, C

    2004-01-01

    The Diamond Light Source is a new medium-energy high brightness synchrotron light facility which is under construction on the Rutherford Appleton Laboratory site in the U.K. The accelerator facility can be divided into three major components; a 3 GeV 561 m circumference storage ring, a full-energy booster synchrotron and a 100 MeV pre-injector linac. This paper describes the linac design and plans for operation. The linac is supplied by ACCEL Instruments GmbH under a turn-key contract, with Diamond Light Source Ltd. providing linac beam diagnostics, control system hardware and standard vacuum components. Commissioning of the linac will take place in early 2005 and user operation of the facility will commence in 2007.

  3. Towards monolithic integration of germanium light sources on silicon chips

    Science.gov (United States)

    Saito, Shinichi; Zaher Al-Attili, Abdelrahman; Oda, Katsuya; Ishikawa, Yasuhiko

    2016-04-01

    Germanium (Ge) is a group-IV indirect band gap semiconductor, and therefore bulk Ge cannot emit light efficiently. However, the direct band gap energy is close to the indirect one, and significant engineering efforts are being made to convert Ge into an efficient gain material monolithically integrated on a Si chip. In this article, we will review the engineering challenges of developing Ge light sources fabricated using nano-fabrication technologies compatible with complementary metal-oxide-semiconductor processes. In particular, we review recent progress in applying high-tensile strain to Ge to reduce the direct band gap. Another important technique is doping Ge with donor impurities to fill the indirect band gap valleys in the conduction band. Realization of carrier confinement structures and suitable optical cavities will be discussed. Finally, we will discuss possible applications of Ge light sources in potential photonics-electronics convergent systems.

  4. Does the velocity of light depend on the source movement?

    CERN Document Server

    Bilbao, Luis

    2016-01-01

    Data from spacecrafts tracking exhibit many anomalies that suggest the dependence of the speed of electromagnetic radiation with the motion of its source. This dependence is different from that predicted from emission theories that long ago have been demonstrated to be wrong. By relating the velocity of light and the corresponding Doppler effect with the velocity of the source at the time of detection, instead of the time of emission, it is possible to explain quantitatively and qualitatively the spacecraft anomalies. Also, a formulation of electromagnetism compatible with this conception is possible (and also compatible with the known electromagnetic phenomena). Under this theory the influence of the velocity of the source in the speed of light is somewhat subtle in many practical situations and probably went unnoticed in other phenomena.

  5. Does the Velocity of Light Depend on the Source Movement?

    Science.gov (United States)

    Bilbao, Luis

    2016-10-01

    Data from spacecrafts tracking exhibit many anomalies that suggest the dependence of the speed of electromagnetic radiation with the motion of its source. This dependence is different from that predicted from emission theories that long ago have been demonstrated to be wrong. By relating the velocity of light and the corresponding Doppler effect with the velocity of the source at the time of detection, instead of the time of emission, it is possible to explain quantitatively and qualitatively the spacecraft anomalies. Also, a formulation of electromagnetism compatible with this conception is possible (and also compatible with the known electromagnetic phenomena). Under this theory the influence of the velocity of the source in the speed of light is somewhat subtle in many practical situations and probably went unnoticed in other phenomena.

  6. Performance characteristics of white light sources consisting of multiple light-emitting diodes

    Science.gov (United States)

    Li, Yun-Li; Shah, Jay M.; Leung, P.-H.; Gessmann, Thomas; Schubert, E. F.

    2004-01-01

    The performance characteristics of white light sources based on a multiple-LED approach, in particular dichromatic and trichromatic sources are analyzed in detail. Figures of merit such as the luminous efficacy, color temperature, and color rendering capabilities are provided for a wide range of primary emission wavelengths. Spectral power density functions of LEDs are assumed to be thermally and inhomogeneously broadened to a full width at half maximum of several kT, in agreement with experimental results. A gaussian line shape is assumed for each of the emission bands. It is shown that multi-LED white light sources have the potential for luminous efficacies greater than 400 lm/W (dichromatic source) and color rendering indices of greater than 90 (trichromatic source). Contour maps for the color rendering indices and luminous efficacies versus three wavelengths are given.

  7. Miniature field emission light sources for bio-chips

    Energy Technology Data Exchange (ETDEWEB)

    Cichy, Bartlomiej; Gorecka-Drzazga, Anna; Dziuban, Jan A [Faculty of Microsystem Electronics and Photonics, Wroclaw University of Technology, Janiszewskiego 11/17, 50-372 Wroclaw (Poland)], E-mail: bartlomiej.cichy@pwr.wroc.pl

    2009-01-01

    A concept based on preparation of miniature field emission light sources (FELS) for integration with bio-chips is presented. Glass and silicon-glass micro-fluidic systems (biochips) with spectrofluorometric detection are designated for this solution. Planar, miniature silicon-glass field emission light sources were designed and fabricated for this conception. Carbon nanotubes (CNTs) have been used as a low-voltage electron emissive layer. Nanocrystalline yttria matrices doped with rare earth (Re) ions (Re: Eu{sup 3+}, Tb{sup 3+}) have been synthesized and utilized as phosphor layers. Light emission spectral characteristics of fabricated sources allow to couple them with typical fluorescent markers as e.g. Alexa, Fluorescein or TO-PRO, used on the wide scale in biochemical researches. Fabricated FELSs are characterized by the intensive and homogenous light emission with well defined sharp emission lines. The efficient and stable field emission from carbon nanotubes has also been noticed. Fabricated FELS are technologically compatible with highly developing micromachined fluidic systems and are able to direct on-chip integration with these microsystems.

  8. Narrow-Bandwidth Diode-Laser-Based Ultraviolet Light Source

    Institute of Scientific and Technical Information of China (English)

    PENG Yu; FANG Zhan-Jun; ZANG Er-Jun

    2011-01-01

    A compact, tunable and narrow-bandwidth laser source for ultraviolet radiation is presented. A grating stabilized diode laser at 1064 nm is frequency-stabilized to below 10 kHz by using a ultra low expansion (ULE) cavity. Injecting light of the diode laser into a tapered amplifier yields a power of 290mW. In a first frequency-doubling stage, about 47 mW of green light at 532nm is generated by using a periodical// poled KTP crystal. Subsequent second-harwonic generation employing a BBO crystal leads to about 30μW of ultraviolet light at 266nm.%A compact,tunable and narrow-bandwidth laser source for ultraviolet radiation is presented.A grating stabilized diode laser at 1064nm is frequency-stabilized to below 10kHz by using a ultra low expansion (ULE) cavity.Injecting light of the diode laser into a tapered amplifier yields a power of 290 mW.In a first frequency-doubling stage,about 47mW of green light at 532nm is generated by using a periodically poled KTP crystal.Subsequent second-harmonic generation employing a BBO crystal leads to about 30 μ W of ultraviolet light at 266nm.Hg is,so far,the heaviest nonradioactive atom that has been laser-cooled and trapped.Systematic evaluation of various sources of uncertainty for the Hg-based optical lattice clock is obtained and an accuracy of better than 10-1s is attainable,which is an order of magnitude of improvement over Sr or Yb based clocks because of the reduced susceptibility to the blackbody radiation field,which sets a major limitation on the accuracy of atomic clocks.[1] The 1S0-3p0 transition at 265.6 nm will be exploited as a clock transition.

  9. Silicon-Based Light Sources for Silicon Integrated Circuits

    Directory of Open Access Journals (Sweden)

    L. Pavesi

    2008-01-01

    Full Text Available Silicon the material per excellence for electronics is not used for sourcing light due to the lack of efficient light emitters and lasers. In this review, after having introduced the basics on lasing, I will discuss the physical reasons why silicon is not a laser material and the approaches to make it lasing. I will start with bulk silicon, then I will discuss silicon nanocrystals and Er3+ coupled silicon nanocrystals where significant advances have been done in the past and can be expected in the near future. I will conclude with an optimistic note on silicon lasing.

  10. Excitation of anodized alumina films with a light source

    DEFF Research Database (Denmark)

    Aggerbeck, Martin; Canulescu, Stela; Rechendorff, K.;

    . The UV-VIS reflectance of Ti-doped anodized aluminium films was measured over the wavelength range of 200 nm to 900 nm. Titanium doped-anodized aluminium films with 5-15 wt% Ti were characterized. Changes in the diffuse light scattering of doped anodized aluminium films, and thus optical appearance......Optical properties of anodized aluminium alloys were determined by optical diffuse reflectance spectroscopy of such films. Samples with different concentrations of dopants were excited with a white-light source combined with an integrating sphere for fast determination of diffuse reflectance...

  11. Direct Seeded Single Frequency mid-IR OPA all Passive Light Source

    DEFF Research Database (Denmark)

    Høgstedt, Lasse; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2013-01-01

    We present a two stage pulsed mid-infrared light source based on nonlinear downconversion of light. The light source is single frequency, tunable, all passive, single moded and build with standard optical components.......We present a two stage pulsed mid-infrared light source based on nonlinear downconversion of light. The light source is single frequency, tunable, all passive, single moded and build with standard optical components....

  12. The advanced light source: America`s brightest light for science and industry

    Energy Technology Data Exchange (ETDEWEB)

    Cross, J.; Lawler, G.

    1994-03-01

    America`s brightest light comes from the Advanced Light Source (ALS), a national facility for scientific research, product development, and manufacturing. Completed in 1993, the ALS produces light in the ultraviolet and x-ray regions of the spectrum. Its extreme brightness provides opportunities for scientific and technical progress not possible anywhere else. Technology is poised on the brink of a major revolution - one in which vital machine components and industrial processes will be drastically miniaturized. Industrialized nations are vying for leadership in this revolution - and the huge economic rewards the leaders will reap.

  13. Current schemes for National Synchrotron Light Source UV beamlines

    Energy Technology Data Exchange (ETDEWEB)

    Williams, G.P.; Howells, M.R.; McKinney, W.R.

    1979-01-01

    We describe in some detail four beamlines proposed for the National Synchrotron Light Source uv ring at Brookhaven National Laboratory. Three grazing-incidence instruments, one of the plane grating Mijake type and two with toroidal gratings at grazing angles of 2-1/2/sup 0/ and 15/sup 0/ are described. Two normal incidence instruments, one using the source as entrance slit and accepting 75 milliradians horizontally are also discussed. In each case we have estimated the output fluxes expected from such beamlines.

  14. Calibration of space instruments at the Metrology Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Klein, R., E-mail: roman.klein@ptb.de; Fliegauf, R.; Gottwald, A.; Kolbe, M.; Paustian, W.; Reichel, T.; Richter, M.; Thornagel, R.; Ulm, G. [Physikalisch-Technische Bundesanstalt (PTB), Berlin (Germany)

    2016-07-27

    PTB has more than 20 years of experience in the calibration of space-based instruments using synchrotron radiation to cover the UV, VUV and X-ray spectral range. New instrumentation at the electron storage ring Metrology Light Source (MLS) opens up extended calibration possibilities within this framework. In particular, the set-up of a large vacuum vessel that can accommodate entire space instruments opens up new prospects. Moreover, a new facility for the calibration of radiation transfer source standards with a considerably extended spectral range has been put into operation. Besides, characterization and calibration of single components like e.g. mirrors, filters, gratings, and detectors is continued.

  15. Development of 250W EUV light source for HVM lithography

    Science.gov (United States)

    Mizoguchi, Hakaru; Nakarai, Hiroaki; Abe, Tamotsu; Nowak, Krzysztof M.; Kawasuji, , Yasufumi; Tanaka, Hiroshi; Watanabe, Yukio; Hori, Tsukasa; Kodama, Takeshi; Shiraishi, Yutaka; Yanagida, Tatsuya; Yamada, Tsuyoshi; Yamazaki, Taku; Okazaki, Shinji; Saitou, Takashi

    2017-02-01

    We have been developing CO2-Sn-LPP EUV light source which is the most promising solution as the 13.5nm high power light source for HVM EUVL since 2003. Unique original technologies such as; combination of pulsed CO2 laser and Sn droplets, dual wavelength laser pulse shooting and mitigation with magnetic field have been developed in Gigaphoton Inc.. The theoretical and experimental data have clearly showed the advantage of our proposed strategy. We demonstrated 117W EUV power (I/F clean in burst), 50 kHz, 22 hours stable operation at Pilot #1 device. Target of this device is 250 W EUV power by 27 kW pulsed CO2 driver laser system.

  16. Intensity noise and spontaneous emission coupling in superluminescent light sources

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, H.F. (Dept. of Electrical Engineering, Texas A and M Univ., College Station, TX (US))

    1990-01-01

    A simple expression for the noise in the photocurrent generated by the detection of light from an ideal superluminescent source is derived using a quantum amplifier model. The excess noise factor {ital X} is found to be related to the photocurrent {ital I{sub d}}, electronic charge, {ital e}, spontaneous emission coupling factor {ital K}, and full width at half maximum power of the emission spectrum {Delta}{ital v}{sub 1/2} by the expression {ital X} = 0.664 {ital I{sub d}/eK}{Delta}{ital v}{sub 1/2}. Implications of this result for the performance of fiberoptic gyroscopes using superluminescent diode (SLD) light sources and for the design of low-noise SLD's are discussed.

  17. X-ray detectors at the Linac Coherent Light Source.

    Science.gov (United States)

    Blaj, Gabriel; Caragiulo, Pietro; Carini, Gabriella; Carron, Sebastian; Dragone, Angelo; Freytag, Dietrich; Haller, Gunther; Hart, Philip; Hasi, Jasmine; Herbst, Ryan; Herrmann, Sven; Kenney, Chris; Markovic, Bojan; Nishimura, Kurtis; Osier, Shawn; Pines, Jack; Reese, Benjamin; Segal, Julie; Tomada, Astrid; Weaver, Matt

    2015-05-01

    Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a new generation of cameras under development at SLAC, is introduced.

  18. Cathode R&D for Future Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, D.H.; /SLAC; Bazarov, I.; Dunham, B.; /Cornell U., CLASSE; Harkay, K.; /Argonne; Hernandez-Garcia; /Jefferson Lab; Legg, R.; /Wisconsin U., SRC; Padmore, H.; /LBL, Berkeley; Rao, T.; Smedley, J.; /Brookhaven; Wan, W.; /LBL, Berkeley

    2010-05-26

    This paper reviews the requirements and current status of cathodes for accelerator applications, and proposes a research and development plan for advancing cathode technology. Accelerator cathodes need to have long operational lifetimes and produce electron beams with a very low emittance. The two principal emission processes to be considered are thermionic and photoemission with the photocathodes being further subdivided into metal and semi-conductors. Field emission cathodes are not included in this analysis. The thermal emittance is derived and the formulas used to compare the various cathode materials. To date, there is no cathode which provides all the requirements needed for the proposed future light sources. Therefore a three part research plan is described to develop cathodes for these future light source applications.

  19. The Development of the Linac Coherent Light Source RF Gun

    CERN Document Server

    Dowell, David H; Lewandowski, James; Limborg-Deprey, Cecile; Li, Zenghai; Schmerge, John; Vlieks, Arnold; Wang, Juwen; Xiao, Liling

    2015-01-01

    The Linac Coherent Light Source (LCLS) is the first x-ray laser user facility based upon a free electron laser (FEL). In addition to many other stringent requirements, the LCLS XFEL requires extraordinary beam quality to saturate at 1.5 angstroms within a 100 meter undulator.[1] This new light source is using the last kilometer of the three kilometer linac at SLAC to accelerate the beam to an energy as high as 13.6 GeV and required a new electron gun and injector to produce a very bright beam for acceleration. At the outset of the project it was recognized that existing RF guns had the potential to produce the desired beam but none had demonstrated it. This paper describes the analysis and design improvements of the BNL/SLAC/UCLA s-band gun leading to achievement of the LCLS performance goals.

  20. Insertion devices at the Swiss Light Source (phase I)

    CERN Document Server

    Schmidt, T; Imhof, A; Patterson, B D; Patthey, L; Quitmann, C; Schulze-Briese, C; Abela, R

    2001-01-01

    The insertion devices under construction for phase I of the Swiss Light Source (SLS) are described. Five undulators and one wiggler will be installed in four straight sections of the third generation 2.4 GeV SLS storage ring, under construction at the Paul Scherrer Institute. To provide undulator radiation in the energy range from 10 eV to 18 keV, both long period and short period, small gap undulators will be installed.

  1. Electron Beam Collimation for the Next Generation Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Steier, C.; Emma, P.; Nishimura, H.; Papadopoulos, C.; Sannibale, F.

    2013-05-20

    The Next Generation Light Source will deliver high (MHz) repetition rate electron beams to an array of free electron lasers. Because of the significant average current in such a facility, effective beam collimation is extremely important to minimize radiation damage to undulators, prevent quenches of superconducting cavities, limit dose rates outside of the accelerator tunnel and prevent equipment damage. This paper describes the early conceptual design of a collimation system, as well as initial results of simulations to test its effectiveness.

  2. Lasers or light sources for treating port-wine stains

    DEFF Research Database (Denmark)

    Faurschou, Annesofie; Olesen, Anne Braae; Leonardi-Bee, Jo;

    2011-01-01

    Port-wine stains are birthmarks caused by malformations of blood vessels in the skin. Port-wine stains manifest themselves in infancy as a flat, red mark and do not regress spontaneously but may, if untreated, become darker and thicker in adult life. The profusion of various lasers and light...... sources makes it difficult to decide which equipment is the best for treating port-wine stains....

  3. Minimum emittance of isochronus rings for synchrotron light source

    CERN Document Server

    Shoji, Y

    1999-01-01

    Theoretically achievable minimum emittances of isochronus rings for synchrotron light source are calculated. The rings discussed in this paper consist of isochronus and achromatic bending cells, isochronus TBA (triple bend achromat) cells with negative dispersion, isochronus TBA cells with inverse bends or isochronus QBA (four bend achromat) cells. We show that the minimum emittances of these rings are roughly 2 or 3 times of those of the optimized non-isochronus rings.

  4. Visible light scatter as quantitative information source on milk constituents

    DEFF Research Database (Denmark)

    Melentieva, Anastasiya; Kucheryavskiy, Sergey; Bogomolov, Andrey

    2012-01-01

    VISIBLE LIGHT SCATTER AS A QUANTITATIVE INFORMATION SOURCE ON MILK CONSTITUENTS A. Melenteva 1, S. Kucheryavski 2, A. Bogomolov 1,31Samara State Technical University, Molodogvardeyskaya Street 244, 443100 Samara, Russia. 2Aalborg University, campus Esbjerg, Niels Bohrs vej 8, 6700 Esbjerg, Denmar...... research area are presented and discussed. References: [1] A. Bogomolov, S. Dietrich, B. Boldrini, R.W. Kessler, Food Chemistry (2012), doi:10.1016/j.foodchem.2012.02.077....

  5. Application research of tune measurement system in Hefei light source

    CERN Document Server

    Sun Bao Gen; Xu Hong Liang; Lu Ping; Wang Jun; Gao Yun Feng; Wang Li; LiuJinYing

    2002-01-01

    The author introduces the measurement and research of some beam parameters using tune measurement system for Hefei Light Source (HLS), which include the betatron tune, beta function, natural chromaticity, corrected chromaticity, and central frequency. Additionally, it also describes the measurement of the influence of DC clearing electrodes on the betatron tune shift and gives some measurement results. The measurement results are compared with the theoretical values and they are in good agreement

  6. Experimental stations at I13 beamline at Diamond Light Source

    Science.gov (United States)

    Pešić, Z. D.; De Fanis, A.; Wagner, U.; Rau, C.

    2013-03-01

    The I13 beamline of Diamond Light Source has been operational since December 2011. The beamline encompass two fully independent branches devoted to coherent imaging experiments (coherent x-ray diffraction, coherent diffraction imaging and ptychography) and x-ray imaging (in-line phase contrast imaging, tomography and full-field microscopy). This paper gives an overview of the current status of experimental stations on both branches and outlines planned developments.

  7. Circular dichroism beamline B23 at the Diamond Light Source.

    Science.gov (United States)

    Hussain, Rohanah; Jávorfi, Tamás; Siligardi, Giuliano

    2012-01-01

    Synchrotron radiation circular dichroism (SRCD) is a well established technique in structural biology. The first UV-VIS beamline, dedicated to circular dichroism, at Diamond Light Source Ltd, a third-generation synchrotron facility in south Oxfordshire, UK, has recently become operational and it is now available for the user community. Herein the main characteristics of the B23 SRCD beamline, the ancillary facilities available for users, and some of the recent advances achieved are summarized.

  8. Harmonic sextupoles for the Advanced Light Source low emittance upgrade

    Science.gov (United States)

    Madur, A.; Arbelaez, D.; Marks, S.; Prestemon, S.; Robin, D.; Schlueter, R.; Steier, C.; Wan, W.

    2011-09-01

    The Advanced Light Source is a 3rd generation light source in operation since 1993. This light source is providing state of the art performance to more than 40 beamlines and their users thanks to the upgrades that have been completed over the last few years. Higher photon beam brightness is expected to become available to users in the near future through a new upgrade with the introduction of 48 sextupoles in the ALS lattice. Introducing new combined function magnets in an existing storage ring is a challenge due to the limited space available and a balance had to be found between magnet performance and spatial constraints. Moreover, the existing steering magnets will be replaced by the harmonic sextupoles. Therefore predicting the hysteresis behavior of the harmonic sextupole steering functions became critical for those included in the fast-orbit feedback loop (22 of them). After a brief introduction to the motivation for the upgrade and the scope of the project, we develop in this paper the different constraints driving the three required combined function magnet designs as well as their expected performance.

  9. High-performance next-generation EUV lithography light source

    Science.gov (United States)

    Choi, Peter; Zakharov, Sergey V.; Aliaga-Rossel, Raul; Benali, Otman; Duffy, Grainne; Sarroukh, Ouassima; Wyndham, Edmund; Zakharov, Vasily S.

    2009-03-01

    EUVL solution for HVM at the 22 nm node requires a high power long-term EUV source operation with hundreds of watts at the intermediate focus output. EUV mask blank and mask defects inspections require at-wavelength tools with high brightness. Theoretical analysis with a 2-D radiation MHD code Z* has been performed to address key issues in EUV plasma sources with radiation transfer. The study shows that self-absorption defines the limiting brightness of a single EUV source, which cannot meet the requirements of the HVM tool with high efficiency and is not sufficient for critical metrology applications, given the limiting etendue of the optics. It is shown that the required irradiance can be achieved by spatial multiplexing, using multiple small sources. We present here details of the study, as well as experimental results from a novel EUV light source with an intrinsic photon collector demonstrating high brightness, the i-SoCoMo concept, where an impulse micro discharge plasma source is integrated to a photon collector based on an active plasma structure. The small physical size and low etendue properties of the i-SoCoMo unit allows a large number of such sources to be put together in one physical package and be operated in a multiplexed fashion to meet necessary power requirements.

  10. A novel photocatalytic conversion of Tryptophan to Kynurenine using black light as a light source

    NARCIS (Netherlands)

    Hamdy Mohamed Saad, M.S.; Scott, E.L.; Carr, R.H.; Sanders, J.P.M.

    2012-01-01

    The photocatalytic conversion of an aqueous solution of l-tryptophan (Trp) to kynurenine (KN) was investigated under the illumination of different light sources. Results show that Trp converted to KN with a selectivity of 64% under the illumination of a medium pressure (MP) Hg lamp. KN selectivity w

  11. Stray light in cone beam optical computed tomography: II. Reduction using a convergent light source.

    Science.gov (United States)

    Dekker, Kurtis H; Battista, Jerry J; Jordan, Kevin J

    2016-04-07

    Optical cone beam computed tomography (CBCT) using a broad beam and CCD camera is a fast method for densitometry of 3D optical gel dosimeters. However, diffuse light sources introduce considerable stray light into the imaging system, leading to underestimation of attenuation coefficients and non-uniformities in CT images unless corrections are applied to each projection image. In this study, the light source of a commercial optical CT scanner is replaced with a convergent cone beam source consisting of almost exclusively image forming primary rays. The convergent source is achieved using a small isotropic source and a Fresnel lens. To characterize stray light effects, full-field cone beam CT imaging is compared to fan beam CT (FBCT) using a 1 cm high fan beam aperture centered on the optic axis of the system. Attenuating liquids are scanned within a large 96 mm diameter uniform phantom and in a small 13.5 mm diameter finger phantom. For the uniform phantom, cone and fan beam CT attenuation coefficients agree within a maximum deviation of (1  ±  2)% between mean values over a wide range from 0.036 to 0.43 cm(-1). For the finger phantom, agreement is found with a maximum deviation of (4  ±  2)% between mean values over a range of 0.1-0.47 cm(-1). With the convergent source, artifacts associated with refractive index mismatch and vessel optical features are more pronounced. Further optimization of the source size to achieve a balance between quantitative accuracy and artifact reduction should enable practical, accurate 3D dosimetry, avoiding time consuming 3D scatter measurements.

  12. Stray light in cone beam optical computed tomography: II. Reduction using a convergent light source

    Science.gov (United States)

    Dekker, Kurtis H.; Battista, Jerry J.; Jordan, Kevin J.

    2016-04-01

    Optical cone beam computed tomography (CBCT) using a broad beam and CCD camera is a fast method for densitometry of 3D optical gel dosimeters. However, diffuse light sources introduce considerable stray light into the imaging system, leading to underestimation of attenuation coefficients and non-uniformities in CT images unless corrections are applied to each projection image. In this study, the light source of a commercial optical CT scanner is replaced with a convergent cone beam source consisting of almost exclusively image forming primary rays. The convergent source is achieved using a small isotropic source and a Fresnel lens. To characterize stray light effects, full-field cone beam CT imaging is compared to fan beam CT (FBCT) using a 1 cm high fan beam aperture centered on the optic axis of the system. Attenuating liquids are scanned within a large 96 mm diameter uniform phantom and in a small 13.5 mm diameter finger phantom. For the uniform phantom, cone and fan beam CT attenuation coefficients agree within a maximum deviation of (1  ±  2)% between mean values over a wide range from 0.036 to 0.43 cm-1. For the finger phantom, agreement is found with a maximum deviation of (4  ±  2)% between mean values over a range of 0.1-0.47 cm-1. With the convergent source, artifacts associated with refractive index mismatch and vessel optical features are more pronounced. Further optimization of the source size to achieve a balance between quantitative accuracy and artifact reduction should enable practical, accurate 3D dosimetry, avoiding time consuming 3D scatter measurements.

  13. Sole-Source Lighting for Controlled-Environment Agriculture

    Science.gov (United States)

    Mitchell.Cary; Stutte, Gary W.

    2015-01-01

    Since plants on Earth evolved under broad-spectrum solar radiation, anytime they are grown exclusively under electric lighting that does not contain all wavelengths in similar proportion to those in sunlight, plant appearance and size could be uniquely different. Nevertheless, plants have been grown for decades under fluorescent (FL) (1) + incandescent (IN) (2) lamps as a sole source of lighting (SSL), and researchers have become comfortable that, in certain proportions of FL + IN for a given species, plants can appear "normal" relative to their growth outdoors. The problem with using such traditional SSLs for commercial production typically is short lamp lifespans and not obtaining enough photosynthetically active radiation (PAR, 400-700 nm) when desired. These limitations led to supplementation of FL + IN lamp outputs with longer-lived, high-intensity discharge (HID) lamps in growth chambers (3). As researchers became comfortable that mixes of orange-biased high-pressure sodium (HPS) and blue-biased metal halide (MH) HIDs together also could give normal plant growth at higher intensities, growth chambers and phytotrons subsequently were equipped mainly with HID lamps, with their intense thermal output filtered out by ventilated light caps or thermal-controlled water barriers. For the most part, IN and HID lamps have found a home in commercial protected horticulture, usually for night-break photoperiod lighting (IN) or for seasonal supplemental lighting (mostly HPS) in greenhouses. However, lack of economically viable options for SSL have held back aspects of year-round indoor agriculture from taking off commercially.

  14. Precision Calibration via Artificial Light Sources Above the Atmosphere

    Science.gov (United States)

    Albert, J. E.; Fagin, M. H.; Brown, Y. J.; Stubbs, C. W.; Kuklev, N. A.; Conley, A. J.

    2016-05-01

    Deeper understanding of the properties of dark energy via SNIa surveys, and to a large extent other methods as well, will require unprecedented photometric precision. Laboratory and solar photometry and radiometry regularly achieve precisions on the order of parts in ten thousand, but photometric calibration for non-solar astronomy presently remains stuck at the percent or greater level. We discuss our project to erase this discrepancy, and our steps toward achieving laboratory-level photometric precision for surveys late this decade. In particular, we show near-field observations of the balloon-borne light source we are presently testing, in addition to previous work with a calibrated laser source presently in low-Earth orbit. Our technique is additionally applicable to microwave astronomy. Observation of gravitational waves in the polarized CMB will similarly require unprecedented polarimetric and radiometric precision, and we briefly discuss our plans for a calibrated microwave source above the atmosphere as well.

  15. Linac Coherent Light Source: The first five years

    Science.gov (United States)

    Bostedt, Christoph; Boutet, Sébastien; Fritz, David M.; Huang, Zhirong; Lee, Hae Ja; Lemke, Henrik T.; Robert, Aymeric; Schlotter, William F.; Turner, Joshua J.; Williams, Garth J.

    2016-01-01

    A new scientific frontier opened in 2009 with the start of operations of the world's first x-ray free-electron laser (FEL), the Linac Coherent Light Source (LCLS), at SLAC National Accelerator Laboratory. LCLS provides femtosecond pulses of x rays (270 eV to 11.2 keV) with very high peak brightness to access new domains of ultrafast x-ray science. This article presents the fundamental FEL physics and outlines the LCLS source characteristics along with the experimental challenges, strategies, and instrumentation that accompany this novel type of x-ray source. The main part of the article reviews the scientific achievements since the inception of LCLS in the five primary areas it serves: atomic, molecular, and optical physics; condensed matter physics; matter in extreme conditions; chemistry and soft matter, and biology.

  16. Beacon system based on light-emitting diode sources for runways lighting

    Science.gov (United States)

    Montes, Mario González; Vázquez, Daniel; Fernandez-Balbuena, Antonio A.; Bernabeu, Eusebio

    2014-06-01

    New aeronautical ground lighting techniques are becoming increasingly important to ensure the safety and reduce the maintenance costs of the plane's tracks. Until recently, tracks had embedded lighting systems whose sources were based on incandescent lamps. But incandescent lamps have several disadvantages: high energy consumption and frequent breakdowns that result in high maintenance costs (lamp average life-time is ˜1500 operating hours) and the lamp's technology has a lack of new lighting functions, such as signal handling and modification. To solve these problems, the industry has developed systems based on light-emitting diode (LED) technology with improved features: (1) LED lighting consumes one tenth the power, (2) it improves preventive maintenance (an LED's lifetime range is between 25,000 and 100,000 hours), and (3) LED lighting technology can be controlled remotely according to the needs of the track configuration. LEDs have been in use for more than three decades, but only recently, around 2002, have they begun to be used as visual aids, representing the greatest potential change for airport lighting since their inception in the 1920s. Currently, embedded LED systems are not being broadly used due to the specific constraints of the rules and regulations of airports (beacon dimensions, power system technology, etc.). The fundamental requirements applied to embedded lighting systems are to be hosted on a volume where the dimensions are usually critical and also to integrate all the essential components for operation. An embedded architecture that meets the lighting regulations for airport runways is presented. The present work is divided into three main tasks: development of an optical system to optimize lighting according to International Civil Aviation Organization, manufacturing prototype, and model validation.

  17. Light source comprising a common substrate, a first led device and a second led device

    Science.gov (United States)

    Choong, Vi-En

    2010-02-23

    At least one stacked organic or polymeric light emitting diode (PLEDs) devices to comprise a light source is disclosed. At least one of the PLEDs includes a patterned cathode which has regions which transmit light. The patterned cathodes enable light emission from the PLEDs to combine together. The light source may be top or bottom emitting or both.

  18. Linac Coherent Light Source (LCLS) Design Study Report

    Energy Technology Data Exchange (ETDEWEB)

    Cornacchia, Massimo

    1998-12-04

    The Stanford Linear Accelerator Center, in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the wavelength range 1.5-15 {angstrom}. This FEL, called the ''Linac Coherent Light Source'' (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. Starting in FY 1998, the first two-thirds of the SLAC linac will be used for injection into the B factory. This leaves the last one-third free for acceleration to 15 GeV. The LCLS takes advantage of this opportunity, opening the way for the next generation of synchrotron light sources with largely proven technology and cost effective methods. This proposal is consistent with the recommendations of the Report of the Basic Energy Sciences Advisory Committee (Synchrotron Radiation Light Source Working Group, October 18-19, 1997). The report recognizes that ''fourth-generation x-ray sources...will in all likelihood be based on the free electron laser concepts. If successful, this technology could yield improvements in brightness by many orders of magnitude.'' This Design Study, the authors believe, confirms the feasibility of constructing an x-ray FEL based on the SLAC linac. Although this design is based on a consistent and feasible set of parameters, some components require more research and development to guarantee the performance. Given appropriate funding, this R and D phase can be completed in 2 years.

  19. The Use of Light-Emitting Diodes (LEDs) as Green and Red/Far-Red Light Sources in Plant Physiology.

    Science.gov (United States)

    Jackson, David L.; And Others

    1985-01-01

    The use of green, red, and far-red light-emitting diodes (LEDs) as light sources for plant physiological studies is outlined and evaluated. Indicates that LED lamps have the advantage over conventional light sources in that they are lightweight, low-cost, portable, easily constructed, and do not require color filters. (Author/DH)

  20. Revised accident source terms for light-water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Soffer, L. [Nuclear Regulatory Commission, Washington, DC (United States)

    1995-02-01

    This paper presents revised accident source terms for light-water reactors incorporating the severe accident research insights gained in this area over the last 15 years. Current LWR reactor accident source terms used for licensing date from 1962 and are contained in Regulatory Guides 1.3 and 1.4. These specify that 100% of the core inventory of noble gases and 25% of the iodine fission products are assumed to be instantaneously available for release from the containment. The chemical form of the iodine fission products is also assumed to be predominantly elemental iodine. These assumptions have strongly affected present nuclear air cleaning requirements by emphasizing rapid actuation of spray systems and filtration systems optimized to retain elemental iodine. A proposed revision of reactor accident source terms and some im implications for nuclear air cleaning requirements was presented at the 22nd DOE/NRC Nuclear Air Cleaning Conference. A draft report was issued by the NRC for comment in July 1992. Extensive comments were received, with the most significant comments involving (a) release fractions for both volatile and non-volatile species in the early in-vessel release phase, (b) gap release fractions of the noble gases, iodine and cesium, and (c) the timing and duration for the release phases. The final source term report is expected to be issued in late 1994. Although the revised source terms are intended primarily for future plants, current nuclear power plants may request use of revised accident source term insights as well in licensing. This paper emphasizes additional information obtained since the 22nd Conference, including studies on fission product removal mechanisms, results obtained from improved severe accident code calculations and resolution of major comments, and their impact upon the revised accident source terms. Revised accident source terms for both BWRS and PWRS are presented.

  1. An Optically Stabilized Fast-Switching Light Emitting Diode as a Light Source for Functional Neuroimaging

    Science.gov (United States)

    Wagenaar, Daniel A.

    2012-01-01

    Neuroscience research increasingly relies on optical methods for evoking neuronal activity as well as for measuring it, making bright and stable light sources critical building blocks of modern experimental setups. This paper presents a method to control the brightness of a high-power light emitting diode (LED) light source to an unprecedented level of stability. By continuously monitoring the actual light output of the LED with a photodiode and feeding the result back to the LED's driver by way of a proportional-integral controller, drift was reduced to as little as 0.007% per hour over a 12-h period, and short-term fluctuations to 0.005% root-mean-square over 10 seconds. The LED can be switched on and off completely within 100 s, a feature that is crucial when visual stimuli and light for optical recording need to be interleaved to obtain artifact-free recordings. The utility of the system is demonstrated by recording visual responses in the central nervous system of the medicinal leech Hirudo verbana using voltage-sensitive dyes. PMID:22238663

  2. An optically stabilized fast-switching light emitting diode as a light source for functional neuroimaging.

    Directory of Open Access Journals (Sweden)

    Daniel A Wagenaar

    Full Text Available Neuroscience research increasingly relies on optical methods for evoking neuronal activity as well as for measuring it, making bright and stable light sources critical building blocks of modern experimental setups. This paper presents a method to control the brightness of a high-power light emitting diode (LED light source to an unprecedented level of stability. By continuously monitoring the actual light output of the LED with a photodiode and feeding the result back to the LED's driver by way of a proportional-integral controller, drift was reduced to as little as 0.007% per hour over a 12-h period, and short-term fluctuations to 0.005% root-mean-square over 10 seconds. The LED can be switched on and off completely within 100 μs, a feature that is crucial when visual stimuli and light for optical recording need to be interleaved to obtain artifact-free recordings. The utility of the system is demonstrated by recording visual responses in the central nervous system of the medicinal leech Hirudo verbana using voltage-sensitive dyes.

  3. JLab CW Cryomodules for 4th Generation Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Rimmer, Robert; Bundy, Richard; Cheng, Guangfeng; Ciovati, Gianluigi; Clemens, William; Daly, Edward; Henry, James; Hicks, William; Kneisel, Peter; Manning, Stephen; Manus, Robert; Marhauser, Frank; Preble, Joseph; Reece, Charles; Smith, Karl; Stirbet, Mircea; Turlington, Larry; Wang, Haipeng; Wilson, Katherine

    2008-01-23

    Fourth generation light sources hold the prospect of unprecedented brightness and optical beam quality for a wide range of scientific applications. Many of the proposed new facilities will rely on large superconducting radio frequency (SRF) based linacs to provide high energy, low emittance CW electron beams. For high average power applications there is a growing acceptance of energy recovery linac (ERL) technology as the way to support large recirculating currents with modest RF power requirements. CW SRF and high current ERLs are two core competencies at Jefferson Lab. JLab has designed and built a number of CW cryomodules of several different types starting with the original CEBAF design, with variations for higher current in the two generations of JLab’s free-electron laser (FEL), through two intermediate prototypes to the final high-performance module for the 12 GeV upgrade. Each of these represent fully engineered and tested configurations with a variety of specifications that could be considered for possible use in fourth generation light sources. Furthermore JLab has been actively pursuing advanced concepts for highcurrent high-efficiency cryomodules for next generation ERL based FEL’s. These existing and proposed designs span the range from about 1mA single-pass to over 100 mA energy recovered current capability. Specialized configurations also exist for high-current non-energy recovered sections such as the injector region where very high RF power is required. We discuss the performance parameters of these existing and proposed designs and their suitability to different classes of fourth generation light sources.

  4. Producing Terahertz Conherent Synchrotron Radiation Based On Hefei Light Source

    CERN Document Server

    De-Rong, Xu; Yan, Shao

    2014-01-01

    This paper theoretically proves that an electron storage ring can generate coherent radiation in THz region using a quick kicker magnet and an ac sextupole magnet. When the vertical chromaticity is modulated by the ac sextupole magnet, the vertical beam collective motion excited by the kicker produces a wavy spatial structure after a number of longitudinal oscillation periods. We calculate the radiation spectral distribution from the wavy bunch in Hefei Light Source(HLS). If we reduce electron energy to 400MeV, it can produce extremely strong coherent synchrotron radiation(CSR) at 0.115THz.

  5. Satellite-Mounted Light Sources as Photometric Calibration Standards

    CERN Document Server

    Albert, Justin; Battat, James; Dupuis, Grace; Fransham, Kyle; Koopmans, Kristin; Jarrett, Michael

    2009-01-01

    A significant and growing portion of systematic error on a number of fundamental parameters in astrophysics and cosmology is due to uncertainties from absolute photometric and flux standards. A path toward achieving major reduction in such uncertainties may be provided by satellite-mounted light sources, resulting in improvement in the ability to precisely characterize atmospheric extinction, and thus helping to usher in the coming generation of precision results in astronomy. Toward this end, we have performed a campaign of observations of the 532 nm pulsed laser aboard the CALIPSO satellite, using a portable network of cameras and photodiodes, to precisely measure atmospheric extinction.

  6. Singapore Synchrotron Light Source - Status, first results, program

    CERN Document Server

    Moser, H O; Kempson, V C; Kong, J R; Li, Z W; Nyunt, T; Qian, H J; Rossmanith, R; Tor, P H; Wilhelmi, O; Yang, P; Zheng, H W; Underhay, I J

    2003-01-01

    The Singapore Synchrotron Light Source is a general-purpose synchrotron radiation facility serving research organisations and industry. Beamlines active or coming up within 2002 include lithography for micro/nanofabrication, phase contrast imaging, surface science, and X-ray diffraction and absorption. An infrared spectro/microscopy beamline is expected to become operational in 2003. Further beamlines are under discussion with user groups. The Microtron Undulator Radiation Facility (MURF) is under development to provide brilliant VUV radiation and to prepare for subsequent development of an EUV and X-ray FEL.

  7. The Digital Camera Application in the Taiwan Light Source

    CERN Document Server

    Kuo, C H; Hsu, K T; Hsu, S Y; Hu, K H; Lee, D; Wang, C J; Yang, Y T

    2005-01-01

    Digital camera has been adopted for the booster, storage ring and transport-line diagnostic recently at the Taiwan Light Source. The system provides low image distortion transmission over long distance. The system is integrated with control system. Each screen monitor equip with a digital camera. These screen monitors are used for beam profile measurement and help injection condition optimization. Wider dynamic range and highly flexibility of the digital gated camera provide various functional enhancements. System configuration and present status will be summary in this report.

  8. Future Possibilities of the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Cornacchia, M

    2003-12-02

    A study of the potential for the development of the Linac Coherent Light Source beyond the specifications of the baseline design is presented. These future developments include delivery of x-ray pulses in the one femtosecond regime, extension of the spectral range, increase of the FEL power, exploitation of the spontaneous emission, and a more flexible time structure. As this potential is exploited, the LCLS can maintain its role as a world leading instrument for many years beyond its commissioning in 2008 and initial operation as the world's first x-ray free-electron laser.

  9. The risk of retina damage from high intensity light sources.

    Science.gov (United States)

    Pollak, V A; Romanchuk, K G

    1980-05-01

    The risk of thermal damage to the retina of the eye by exposure to excessive light intensities from continuous and pulsed man-made sources is discussed. The probability of injury increases, the larger the radiant power absorbed by the retina and the smaller the size of the retinal image of the source. A mehtod of estimating the temperature increase of the immediately affected area of the retina is presented. The time constants involved are also briefly considered. Using numerical values from literature for the relevant parameters of the eye, threshold values for a variety of conditions can be established. Below these values little risk of retina damage should exist. The degree of hazard when these values are exceeded depends upon the circumstances. A case study of a welding accident showed good agreement between the conclusions of the theoretical analysis and clinical findings.

  10. Inverse free electron laser accelerator for advanced light sources

    Directory of Open Access Journals (Sweden)

    J. P. Duris

    2012-06-01

    Full Text Available We discuss the inverse free electron laser (IFEL scheme as a compact high gradient accelerator solution for driving advanced light sources such as a soft x-ray free electron laser amplifier or an inverse Compton scattering based gamma-ray source. In particular, we present a series of new developments aimed at improving the design of future IFEL accelerators. These include a new procedure to optimize the choice of the undulator tapering, a new concept for prebunching which greatly improves the fraction of trapped particles and the final energy spread, and a self-consistent study of beam loading effects which leads to an energy-efficient high laser-to-beam power conversion.

  11. Penning plasma based simultaneous light emission source of visible and VUV lights

    Science.gov (United States)

    Vyas, G. L.; Prakash, R.; Pal, U. N.; Manchanda, R.; Halder, N.

    2016-06-01

    In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20-106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.

  12. Penning plasma based simultaneous light emission source of visible and VUV lights

    Energy Technology Data Exchange (ETDEWEB)

    Vyas, G. L., E-mail: glvyas27@gmail.com [Manipal University Jaipur (India); Prakash, R.; Pal, U. N. [CSIR-Central Electronics and Engineering Research Institute, Microwave Tubes Division (India); Manchanda, R. [Institute for Plasma Research (India); Halder, N. [Manipal University Jaipur (India)

    2016-06-15

    In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20–106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.

  13. Composite-Light-Source Interferometer for Real-Time Micro-Vibration Measurements

    Institute of Scientific and Technical Information of China (English)

    Dailin Li; Xiangzhao Wang

    2003-01-01

    A novel interferometer using a composite light source for real time measurements of micro-vibrations is proposed.The experimental results make it clear that it is insensitive to external disturbances and intensity fluctuations of the source light.

  14. Composite-Light-Source Interferometer for Real-Time Micro-Vibration Measurements

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A novel interferometer using a composite light source for real time measurements of micro-vibrations is proposed. The experimental results make it clear that it is insensitive to external disturbances and intensity fluctuations of the source light.

  15. Supercontinuum Light Sources for Hyperspectral Subsurface Laser Scattering

    DEFF Research Database (Denmark)

    Nielsen, Otto Højager Attermann; Dahl, Anders Lindbjerg; Larsen, Rasmus;

    2011-01-01

    A materials structural and chemical composition influences its optical scattering properties. In this paper we investigate the use of subsurface laser scattering (SLS) for inferring structural and chemical information of food products. We have constructed a computer vision system based on a super......A materials structural and chemical composition influences its optical scattering properties. In this paper we investigate the use of subsurface laser scattering (SLS) for inferring structural and chemical information of food products. We have constructed a computer vision system based...... on a supercontinuum laser light source and an Acousto- Optic Tunable Filter (AOTF) to provide a collimated light source, which can be tuned to any wavelength in the range from 480 to 900 nm. We present the newly developed hyperspectral vision system together with a proof-of-principle study of its ability...... to discriminate between dairy products with either similar chemical or structural composition. The combined vision system is a new way for industrial food inspection allowing non-intrusive online process inspection of parameters that is hard with existing technology....

  16. SESAME -- A light source for the Middle East

    Science.gov (United States)

    Winick, Herman

    2012-02-01

    Developed under UNESCO and modelled on CERN, SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) is an international research centre in construction in Jordan, enabling world-class research while promoting peace through scientific cooperation. Its centerpiece, a new 2.5 GeV 3rd Generation Electron Storage Ring (133m circumference, 26nm-rad emittance, 12 places for insertion devices), will provide intense light from infra-red to hard X-rays. The Council (Bahrain, Cyprus, Egypt, Iran, Israel, Jordan, Pakistan, Palestinian Authority, Turkey), provides the annual budget. Concrete shielding is complete, and a staff of 21 is installing the refurbished 0.8 GeV BESS Y I injector system, a gift from Germany. The facility can serve 25 simultaneous experiments. Beamline equipment has been provided by Daresbury (UK), the Helmholtz Assoc. (Germany), the Swiss Light Source, LURE (France), the Univ. of Liverpool, Elettra (Italy) and US labs. Jordan has contributed 3.3M, in addition to a building and land. The EU has contributed 4.8M. Commitments confirmed by Members look set to provide most of 35M needed to complete construction of the ring and 3 beamlines. A training program has been underway since 2000. See www.sesame.org.jo

  17. A squeezed light source operated under high vacuum

    Science.gov (United States)

    Wade, Andrew R.; Mansell, Georgia L.; Chua, Sheon S. Y.; Ward, Robert L.; Slagmolen, Bram J. J.; Shaddock, Daniel A.; McClelland, David E.

    2015-01-01

    Non-classical squeezed states of light are becoming increasingly important to a range of metrology and other quantum optics applications in cryptography, quantum computation and biophysics. Applications such as improving the sensitivity of advanced gravitational wave detectors and the development of space-based metrology and quantum networks will require robust deployable vacuum-compatible sources. To date non-linear photonics devices operated under high vacuum have been simple single pass systems, testing harmonic generation and the production of classically correlated photon pairs for space-based applications. Here we demonstrate the production under high-vacuum conditions of non-classical squeezed light with an observed 8.6 dB of quantum noise reduction down to 10 Hz. Demonstration of a resonant non-linear optical device, for the generation of squeezed light under vacuum, paves the way to fully exploit the advantages of in-vacuum operations, adapting this technology for deployment into new extreme environments. PMID:26657616

  18. Future Synchrotron Light Sources Based on Ultimate Storage Rings

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Yunhai; /SLAC

    2012-04-09

    The main purpose of this talk is to describe how far one might push the state of the art in storage ring design. The talk will start with an overview of the latest developments and advances in the design of synchrotron light sources based on the concept of an 'ultimate' storage ring. The review will establish how bright a ring based light source might be, where the frontier of technological challenges are, and what the limits of accelerator physics are. Emphasis will be given to possible improvements in accelerator design and developments in technology toward the goal of achieving an ultimate storage ring. An ultimate storage ring (USR), defined as an electron ring-based light source having an emittance in both transverse planes at the diffraction limit for the range of X-ray wavelengths of interest for a scientific community, would provide very high brightness photons having high transverse coherence that would extend the capabilities of X-ray imaging and probe techniques beyond today's performance. It would be a cost-effective, high-coherence 4th generation light source, competitive with one based on energy recovery linac (ERL) technology, serving a large number of users studying material, chemical, and biological sciences. Furthermore, because of the experience accumulated over many decades of ring operation, it would have the great advantage of stability and reliability. In this paper we consider the design of an USR having 10-pm-rad emittance. It is a tremendous challenge to design a storage ring having such an extremely low emittance, a factor of 100 smaller than those in existing light sources, especially such that it has adequate dynamic aperture and beam lifetime. In many ultra-low emittance designs, the injection acceptances are not large enough for accumulation of the electron beam, necessitating on-axis injection where stored electron bunches are completely replaced with newly injected ones. Recently, starting with the MAX-IV 7-bend

  19. Terahertz Light Source and User Area at FACET

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Z.; Li, S.Z.; Litos, M.; Fisher, A.D.; Hogan, M.J.; /SLAC

    2011-11-08

    FACET at SLAC provides high charge, high peak current, low emittance electron beam that is bunched at THz wavelength scale during its normal operation. A THz light source based coherent transition radiation (CTR) from this beam would potentially be the brightest short-pulse THz source ever constructed. Efforts have been put into building this photon source together with a user area, to provide a platform to utilize this unique THz radiation for novel nonlinear and ultrafast phenomena researches and experiments. Being a long-time underutilized portion of the electromagnetic spectrum, terahertz (100 GHz {approx} 10 THz) spectral range is experiencing a renaissance in recent years, with broad interests from chemical and biological imaging, material science, telecommunication, semiconductor and superconductor research, etc. Nevertheless, the paucity of THz sources especially strong THz radiation hinders both its commercial applications and nonlinear processes research. FACET - Facilities for Accelerator science and Experimental Test beams at SLAC - provides 23 GeV electron beam with peak currents of {approx} 20 kA that can be focused down to 100 {mu}m{sup 2} transversely. Such an intense electron beam, when compressed to sub-picosecond longitudinal bunch length, coherently radiates high intensity EM fields well within THz frequency range that are orders of magnitude stronger than those available from laboratory tabletop THz sources, which will enable a wide variety of THz related research opportunities. Together with a description of the FACET beamline and electron beam parameters, this paper will report FACET THz radiation generation via coherent transition radiation and calculated photon yield and power spectrum. A user table is being set up along the THz radiation extraction sites, and equipped with various signal diagnostics including THz power detector, Michelson interferometer, sample stages, and sets of motorized optical components. This setup will also be

  20. Real-time tunability of chip-based light source enabled by microfluidic mixing

    DEFF Research Database (Denmark)

    Olsen, Brian Bilenberg; Rasmussen, Torben; Balslev, Søren

    2006-01-01

    We demonstrate real-time tunability of a chip-based liquid light source enabled by microfluidic mixing. The mixer and light source are fabricated in SU-8 which is suitable for integration in SU-8-based laboratory-on-a-chip microsystems. The tunability of the light source is achieved by changing...

  1. EDITORIAL: Special Issue on advanced and emerging light sources Special Issue on advanced and emerging light sources

    Science.gov (United States)

    Haverlag, Marco; Kroesen, Gerrit; Ferguson, Ian

    2011-06-01

    The papers in this special issue of Journal of Physics D: Applied Physics (JPhysD) originate from the 12th International Symposium on the Science and Technology of Light Sources and the 3rd International Conference on White LEDs and Solid State Lighting, held 11-16 July 2010 at Eindhoven University. Abstracts of all papers presented at this combined conference were published in the Conference Proceedings LS-WLED 2010 by FAST-LS, edited by M Haverlag, G M W Kroesen and T Taguchi. Special issues of the previous three LS conferences have been well-cited and have proven to be an important source of information for the lighting community. The 2010 LS-Symposium was a combined conference with the White LED Conference in order to enhance the scope of this conference series towards new light source technologies such as LEDs and OLEDs, and this co-operation will be continued in the future. Given the faster technology development in these areas it was also decided to shorten the interval between conferences from three to two years. Well over 200 invited presentations, landmark presentations and poster contributions were presented at the 2010 LS-Symposium. The organizing committee have selected from these a number of outstanding contributions with a high technological content and invited the authors to submit a full paper in JPhysD. The criteria were that the work should not be a repetition of the work already published in the Proceedings, but should be new, complete, within the scope of JPhysD, and meeting the normal quality standards of this journal. After peer review a combined set of 18 papers is published in this JPhysD special issue. In addition, a number of lighting-application-orientated papers will be published in a special issue of Journal of Light & Visual Environment later in 2011. The papers in this special issue of JPhysD show that research in the science and technology of light sources still covers a broad set of subject areas which includes both 'classical

  2. Optical Pumping Experiments on Next Generation Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Moon, S J; Fournier, K B; Scott, H; Chung, H K; Lee, R W

    2004-07-29

    Laser-based plasma spectroscopic techniques have been used with great success to determine the line shapes of atomic transitions in plasmas, study the population kinetics of atomic systems embedded in plasmas, and look at the redistribution of radiation. However, the possibilities for optical lasers end for plasmas with n{sub e}>10{sup 22}cm{sup -3} as light propagation is severely altered by the plasma. The construction of the Tesla Test Facility(TTF) at DESY(Deutsche Elektronen-Synchrotron), a short pulse tunable free electron laser in the vacuum-ultraviolet and soft X-ray regime (VUV FEL), based on the SASE(self amplified spontaneous emission) process, will provide a major advance in the capability for dense plasma-related research. This source will provide 10{sup 13} photons in a 200 fs duration pulse that is tunable from {approx} 6nm to 100nm. Since an VUV FEL will not have the limitation associated with optical lasers the entire field of high density plasmas kinetics in laser produced plasma will then be available to study with tunable source. Thus, one will be able to use this and other FEL x-ray sources to pump individual transitions creating enhanced population in the excited states that can easily be monitored. We show two case studies illuminating different aspects of plasma spectroscopy.

  3. State of Art in the Science and Technology of Electrical Discharge Light Sources

    Science.gov (United States)

    Zissis, Georges; Rouffet, Jean-Baptiste

    Light is vital for life: Light sources play an indispensable role to daily life of any Human being. Our World cannot be conceived without light. Quality of life, health and, somehow, urban security related with traffic and crime prevention measures depend on light and on its quality. The lighting industry is an important economic factor in Europe, USA and many Asiatic Countries. All in all, lighting is an important socio-economic factor and lighting system development should be an integral part of any Sustainable Development and of any program of improvement of Quality of Life. This presentation provides an overview of the present state of research in the science and technology of light sources. Existing technologies and future challenges for the lighting industry will be presented. To better understanding the light source technology an part of this presentation will be devoted to the physics of light sources.

  4. Light-assisted drying (LAD) of small volume biologics: a comparison of two IR light sources

    Science.gov (United States)

    Young, Madison A.; Van Vorst, Matthew; Elliott, Gloria D.; Trammell, Susan R.

    2016-03-01

    Protein therapeutics have been developed to treat diseases ranging from arthritis and psoriasis to cancer. A challenge in the development of protein-based drugs is maintaining the protein in the folded state during processing and storage. We are developing a novel processing method, light-assisted drying (LAD), to dehydrate proteins suspended in a sugar (trehalose) solution for storage at supra-zero temperatures. Our technique selectively heats the water in small volume samples using near-IR light to speed dehydration which prevents sugar crystallization that can damage embedded proteins. In this study, we compare the end moisture content (EMC) as a function of processing time of samples dried with two different light sources, Nd:YAG (1064 nm) and Thulium fiber (1850 nm) lasers. EMC is the ratio of water to dry weight in a sample and the lower the EMC the higher the possible storage temperature. LAD with the 1064 and 1850 nm lasers yielded 78% and 65% lower EMC, respectively, than standard air-drying. After 40 minutes of LAD with 1064 and 1850 nm sources, EMCs of 0.27+/-.27 and 0.15+/-.05 gH2O/gDryWeight were reached, which are near the desired value of 0.10 gH2O/gDryWeight that enables storage in a glassy state without refrigeration. LAD is a promising new technique for the preparation of biologics for anhydrous preservation.

  5. X-ray Optics for BES Light Source Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Dennis [Argonne National Lab. (ANL), Argonne, IL (United States); Padmore, Howard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lessner, Eliane [Dept. of Energy (DOE), Washington DC (United States). Office of Science

    2013-03-27

    potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of

  6. X-ray Optics for BES Light Source Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Dennis [Argonne National Lab. (ANL), Argonne, IL (United States); Padmore, Howard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lessner, Eliane [Dept. of Energy (DOE), Washington DC (United States). Office of Science

    2013-03-27

    potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of

  7. LED based powerful nanosecond light sources for calibration systems of deep underwater neutrino telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Lubsandorzhiev, B.K. [Institute for Nuclear Research of the Russian Academy of Sciences (Russian Federation); Kepler Center for Astro and Particle Physics, University of Tuebingen (Germany)], E-mail: lubsand@pcbai10.inr.ruhep.ru; Poleshuk, R.V.; Shaibonov, B.A.J.; Vyatchin, Y.E. [Institute for Nuclear Research of the Russian Academy of Sciences (Russian Federation)

    2009-04-11

    Powerful nanosecond light sources based on LEDs have been developed for use in calibration systems of deep underwater neutrino telescopes. The light sources use either matrixes of ultra bright blue InGaN LEDs or new generation high power blue LEDs. It is shown that such light sources have light yield of up to 10{sup 10}-10{sup 12} photons per pulse with very fast light emission kinetics. The developed light sources are currently used in a number of astroparticle physics experiments, namely: the lake Baikal neutrino experiment, the TUNKA EAS experiment, etc.

  8. Highlights from e-EPS: Coordinated Access to Light sources

    CERN Multimedia

    e-EPS News

    2014-01-01

    The CALIPSO project, which runs until May 2015, will contribute to the effective exploitation of European synchrotrons and free electron lasers. CALIPSO (Coordinated Access to Light sources to Promote Standards and Optimisation) includes 20 partners forming one of the largest Research Networks in the world.   e-EPS interviewed M. Bertolo, CALIPSO project manager and his assistant C. Blasetti. Which challenges are addressed by CALIPSO? CALIPSO’s goal is to optimize the exploitation of the European synchrotrons and Free Electron Lasers. With respect to previous projects funded by the European Commission, it foresees significant improvements in integration, innovation and user-friendliness in all three areas of networking, transnational access and instrumentation. The Transnational Access program potentially benefits a community of 25,000 estimated users offering free open access to 12 synchrotrons and 5 free electron lasers solely based on scientific merit. In ad...

  9. Semiconductor light source with electrically tunable emission wavelength

    Energy Technology Data Exchange (ETDEWEB)

    Belenky, Gregory (Port Jefferson, NY); Bruno, John D. (Bowie, MD); Kisin, Mikhail V. (Centereach, NY); Luryi, Serge (Setauket, NY); Shterengas, Leon (Centereach, NY); Suchalkin, Sergey (Centereach, NY); Tober, Richard L. (Elkridge, MD)

    2011-01-25

    A semiconductor light source comprises a substrate, lower and upper claddings, a waveguide region with imbedded active area, and electrical contacts to provide voltage necessary for the wavelength tuning. The active region includes single or several heterojunction periods sandwiched between charge accumulation layers. Each of the active region periods comprises higher and lower affinity semiconductor layers with type-II band alignment. The charge carrier accumulation in the charge accumulation layers results in electric field build-up and leads to the formation of generally triangular electron and hole potential wells in the higher and lower affinity layers. Nonequillibrium carriers can be created in the active region by means of electrical injection or optical pumping. The ground state energy in the triangular wells and the radiation wavelength can be tuned by changing the voltage drop across the active region.

  10. Workshop on scientific applications of short wavelength coherent light sources

    Energy Technology Data Exchange (ETDEWEB)

    Spicer, W.; Arthur, J.; Winick, H.

    1993-02-01

    This report contains paper on the following topics: A 2 to 4nm High Power FEL On the SLAC Linac; Atomic Physics with an X-ray Laser; High Resolution, Three Dimensional Soft X-ray Imaging; The Role of X-ray Induced Damage in Biological Micro-imaging; Prospects for X-ray Microscopy in Biology; Femtosecond Optical Pulses ; Research in Chemical Physics Surface Science, and Materials Science, with a Linear Accelerator Coherent Light Source; Application of 10 GeV Electron Driven X-ray Laser in Gamma-ray Laser Research; Non-Linear Optics, Fluorescence, Spectromicroscopy, Stimulated Desorption: We Need LCLS' Brightness and Time Scale; Application of High Intensity X-rays to Materials Synthesis and Processing; LCLS Optics: Selected Technological Issues and Scientific Opportunities; Possible Applications of an FEL for Materials Studies in the 60 eV to 200 eV Spectral Region.

  11. Workshop on scientific applications of short wavelength coherent light sources

    Energy Technology Data Exchange (ETDEWEB)

    Spicer, W.; Arthur, J.; Winick, H.

    1993-02-01

    This report contains paper on the following topics: A 2 to 4nm High Power FEL On the SLAC Linac; Atomic Physics with an X-ray Laser; High Resolution, Three Dimensional Soft X-ray Imaging; The Role of X-ray Induced Damage in Biological Micro-imaging; Prospects for X-ray Microscopy in Biology; Femtosecond Optical Pulses?; Research in Chemical Physics Surface Science, and Materials Science, with a Linear Accelerator Coherent Light Source; Application of 10 GeV Electron Driven X-ray Laser in Gamma-ray Laser Research; Non-Linear Optics, Fluorescence, Spectromicroscopy, Stimulated Desorption: We Need LCLS` Brightness and Time Scale; Application of High Intensity X-rays to Materials Synthesis and Processing; LCLS Optics: Selected Technological Issues and Scientific Opportunities; Possible Applications of an FEL for Materials Studies in the 60 eV to 200 eV Spectral Region.

  12. Suppression of microbunching instability in the linac coherent light source

    Directory of Open Access Journals (Sweden)

    Z. Huang

    2004-07-01

    Full Text Available A microbunching instability driven by longitudinal space charge, coherent synchrotron radiation, and linac wakefields is studied for the linac coherent light source (LCLS accelerator system. Since the uncorrelated (local energy spread of electron beams generated from a photocathode rf gun is very small, the microbunching gain may be large enough to significantly amplify rf-gun generated modulations or even shot-noise fluctuations of the electron beam. The uncorrelated energy spread can be increased by an order of magnitude to provide strong Landau damping against the instability without degrading the free-electron laser performance. We study different damping options in the LCLS and discuss an effective laser heater to minimize the impact of the instability on the quality of the electron beam.

  13. Neon reduction program on Cymer ArF light sources

    Science.gov (United States)

    Kanawade, Dinesh; Roman, Yzzer; Cacouris, Ted; Thornes, Josh; O'Brien, Kevin

    2016-03-01

    In response to significant neon supply constraints, Cymer has responded with a multi-part plan to support its customers. Cymer's primary objective is to ensure that reliable system performance is maintained while minimizing gas consumption. Gas algorithms were optimized to ensure stable performance across all operating conditions. The Cymer neon support plan contains four elements: 1. Gas reduction program to reduce neon by >50% while maintaining existing performance levels and availability; 2. short-term containment solutions for immediate relief. 3. qualification of additional gas suppliers; and 4. long-term recycling/reclaim opportunity. The Cymer neon reduction program has shown excellent results as demonstrated through the comparison on standard gas use versus the new >50% reduced neon performance for ArF immersion light sources. Testing included stressful conditions such as repetition rate, duty cycle and energy target changes. No performance degradation has been observed over typical gas lives.

  14. NATIONAL SYNCHROTRON LIGHT SOURCE MEDICAL PERSONNEL PROTECTION INTERLOCK

    Energy Technology Data Exchange (ETDEWEB)

    BUDA,S.; GMUR,N.F.; LARSON,R.; THOMLINSON,W.

    1998-11-03

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated.

  15. Pixel detector system development at Diamond Light Source

    Science.gov (United States)

    Marchal, J.; Horswell, I.; Gimenez, E. N.; Tartoni, N.

    2010-10-01

    Hybrid pixel detectors consisting of an array of silicon photodiodes bump-bonded to CMOS read-out chips provide high signal-to-noise ratio and high dynamic range compared to CCD-based detectors and Image Plates. These detector features are important for SAXS experiments where a wide range of intensities are present in the images. For time resolved SAXS experiments, high frame rates are compulsory. The latest CMOS read-out chip developed by the MEDIPIX collaboration provides high frame rate and continuous acquisition mode. A read-out system for an array of MEDIPIX3 sensors is under development at Diamond Light Source. This system will support a full resolution frame rate of 1 kHz at a pixel counter depth of 12-bit and a frame rate of 30 kHz at a counter depth of 1 bit. Details concerning system design and MEDIPIX sensors characterization are presented.

  16. An integrated source of broadband quadrature squeezed light

    CERN Document Server

    Hoff, Ulrich B; Andersen, Ulrik L

    2015-01-01

    An integrated silicon nitride resonator is proposed as an ultra-compact source of bright single-mode quadrature squeezed light at 850 nm. Optical properties of the device are investigated and tailored through numerical simulations, with particular attention paid to loss associated with interfacing the device. An asymmetric double layer stack waveguide geometry with inverse vertical tapers is proposed for efficient and robust fibre-chip coupling, yielding a simulated total loss of -0.75 dB/facet. We assess the feasibility of the device through a full quantum noise analysis and derive the output squeezing spectrum for intra-cavity pump self-phase modulation. Subject to standard material loss and detection efficiencies, we find that the device holds promises for generating substantial quantum noise squeezing over a bandwidth exceeding 1 GHz. In the low-propagation loss regime, approximately -7 dB squeezing is predicted for a pump power of only 50 mW.

  17. Suppression of Microbunching Instability in the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Z

    2004-03-02

    A microbunching instability driven by longitudinal space charge, coherent synchrotron radiation, and linac wakefields is studied for the linac coherent light source (LCLS) accelerator system. Since the uncorrelated (local) energy spread of electron beams generated from a photocathode rf gun is very small, the microbunching gain may be large enough to significantly amplify rf-gun generated modulations or even shot-noise fluctuations of the electron beam. The uncorrelated energy spread can be increased by an order of magnitude to provide strong Landau damping against the instability without degrading the free-electron laser performance. We study different damping options in the LCLS and discuss an effective laser heater to minimize the impact of the instability on the quality of the electron beam.

  18. A Next Generation Light Source Facility at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    Corlett, J.N.; Austin, B.; Baptiste, K.M.; Byrd, J.M.; Denes, P.; Donahue, R.; Doolittle, L.; Falcone, R.W.; Filippetto, D.; Fournier, S.; Li, D.; Padmore, H.A.; Papadopoulos, C.; Pappas, C.; Penn, G.; Placidi, M.; Prestemon, S.; Prosnitz, D.; Qiang, J.; Ratti, A.; Reinsch, M.; Sannibale, F.; Schlueter, R.; Schoenlein, R.W.; Staples, J.W.; Vecchione, T.; Venturini, M.; Wells, R.; Wilcox, R.; Wurtele, J.; Charman, A.; Kur, E.; Zholents, A.A.

    2011-03-23

    The Next Generation Light Source (NGLS) is a design concept, under development at LBNL, for a multibeamline soft x-ray FEL array powered by a ~;;2 GeV superconducting linear accelerator, operating with a 1 MHz bunch repetition rate. The CW superconducting linear accelerator is supplied by a high-brightness, highrepetition- rate photocathode electron gun. Electron bunches are distributed from the linac to the array of independently configurable FEL beamlines with nominal bunch rates up to 100 kHz in each FEL, and with even pulse spacing. Individual FELs may be configured for EEHG, HGHG, SASE, or oscillator mode of operation, and will produce high peak and average brightness x-rays with a flexible pulse format, with pulse durations ranging from sub-femtoseconds to hundreds of femtoseconds.

  19. VCSELs as light source for time-of-flight sensors

    Science.gov (United States)

    Moench, Holger; Frey, Manuel; Grabherr, Martin; Gronenborn, Stephan; Gudde, Ralph; Kolb, Johanna; Miller, Michael; Weigl, Alexander

    2017-02-01

    VCSELs and VCSEL arrays are an ideal light source for time-of-flight based sensors. The narrow emission spectrum and the ability for short pulses make them superior to LEDs. Combined with fast photodiodes or special camera chips spatial 3D information can be obtained which is needed in diverse applications like camera autofocus, indoor navigation, 3Dobject recognition or even autonomously driving vehicles. VCSEL arrays are the way to tailor the output power. For pulse operation at low duty cycle average heat dissipation is no longer the upper limit to the operating point of VCSELs but over-pulsing becomes possible. Taking into account electrical boundary conditions and optimum conversion efficiency arrays can be designed for specific operating conditions. Measurements of arrays under short pulse operation are presented using a package with integrated driver.

  20. Observation of nonlinear resonances in the advanced light source

    Science.gov (United States)

    Robin, D.; Collins, H.; Decking, W.; Portmann, G.; Schachinger, L.; Zholents, A.

    1995-09-01

    Observations of nonlinear resonances in the Advanced Light Source have been made by scanning betatron tunes and observing count rates in a beam-loss radiation monitor placed down stream of a beam scraper. We have found that it is possible to see structural resonances which are unallowed as well as those which are allowed by the ring's natural 12-fold symmetry. By systematically breaking the amount of symmetry we see that the widths of the unallowed resonances grow while the widths of the allowed resonances do not. In this paper we briefly discuss the importance of symmetry and its effect on resonances in the design of the ALS. Next we describe our experimental setup and discuss the performance of the beam loss monitor which we used to view the resonances. We then present scans of the tune space where one can see the presence of the structural resonances and their evolution when the lattice symmetry is systematically broken.

  1. The macromolecular crystallography facility at the advanced light source

    Science.gov (United States)

    Earnest, Thomas; Padmore, Howard; Cork, Carl; Behrsing, Rolf; Kim, Sung-Hou

    1996-10-01

    Synchrotron radiation offers several advantages over the use of rotating anode sources for biological crystallography, which allow for the collection of higher-resolution data, substantially more rapid data collection, phasing by multiwavelength anomalous diffraction (MAD) techniques, and time-resolved experiments using polychromatic radiation (Laue diffraction). The use of synchrotron radiation is often necessary to record useful data from crystals which diffract weakly or have very large unit cells. The high brightness and stability characteristics of the advanced light source (ALS) at Lawrence Berkeley National Laboratory, along with the low emittance and long straight sections to accommodate insertion devices present in third generation synchrotrons like the ALS, lead to several advantages in the field of macromolecular crystallography. We are presently constructing a macromolecular crystallography facility at the ALS which is optimized for user-friendliness and high-throughput data collection, with advanced capabilities for MAD and Laue experiments. The X-rays will be directed to three branchlines. A well-equipped support lab will be available for biochemistry, crystal mounting and sample storage, as well as computer hardware and software available, along with staff support, allowing for the complete processing of data on site.

  2. Status of PEP-X Light Source Design Study

    Energy Technology Data Exchange (ETDEWEB)

    Bane, K.L.F.; Bertsche, K.J.; Cai, Y.; Chao, A.; Huang, X.; Jiao, Y.; Ng, C.-K.; Nosochkov, Y.; Novokhatski, A.; Rivetta, C.H.; Safranek, J.A.; Stupakov, G.V.; Wang, L.; Wang, M.-H.; Xiao, L.; /SLAC; Hettel, R.O.; /SLAC; Rabedeau, T.; /SLAC

    2011-12-14

    The SLAC Beam Physics group and other SLAC collaborators continue to study options for implementing a near diffraction-limited ring-based light source in the 2.2-km PEP-II tunnel that will serve the SSRL scientific program in the future. The study team has completed the baseline design for a 4.5-GeV storage ring having 160 pm-rad emittance with stored beam current of 1.5 A, providing >10{sup 22} brightness for multi-keV photon beams from 3.5-m undulator sources. The team has also investigated possible 5-GeV ERL configurations which, similar to the Cornell and KEK ERL plans, would have {approx}30 pm-rad emittance with 100 mA current, and {approx}10 pm-rad emittance with 25 mA or less. Now a 4.5-GeV 'ultimate' storage ring having emittance similar to the ERL and operating with {approx}200 mA is under study. An overview of the progress of the PEP-X design study and SSRL's plans for defining performance parameters that will guide the choice of ring options is presented.

  3. RF Design for the Linac Coherent Light Source (LCLS) Injector

    CERN Document Server

    Dowell, D H; Boyce, Richard F; Hodgson, J A; Li, Zenghai; Limborg-Deprey, C; Xiao, Liling; Yu, Nancy

    2004-01-01

    The Linac Coherent Light Source (LCLS) will be the world’s first free electron laser, and the successful operation of this very short-wavelength FEL will require excellent beam quality from its electron source. Therefore a critical component is the RF photocathode injector. This paper describes the design issues of the LCLS RF gun and accelerator structures. The injector consists of a 1.6 cell s-band gun followed by two 3-meter SLAC sections. The gun and the first RF section will have dual RF feeds both to eliminate transverse RF kicks and to reduce the pulsed heating of the coupling ports. In addition, the input coupler cavity of the first accelerator section will be specially shaped to greatly reduce the RF quadrupole fields. The design for the accelerator section is now complete, and the RF design of the gun’s dual coupler and the full cell shape is in progress. These and other aspects of the gun and structure designs will be discussed.

  4. National Synchrotron Light Source guidelines for the conduct of operations

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, M. [Brookhaven National Lab., Upton, NY (United States). National Synchrotron Light Source

    1998-01-01

    To improve the quality and uniformity of operations at the Department of Energy`s facilities, the DOE issued Order 5480.19 ``Conduct of Operations Requirements at DOE facilities.`` This order recognizes that the success of a facilities mission critically depends upon a high level of performance by its personnel and equipment. This performance can be severely impaired if the facility`s Conduct of Operations pays inadequate attention to issues of organization, safety, health, and the environment. These guidelines are Brookhaven National Laboratory`s and the National Synchrotron Light Source`s acknowledgement of the principles of Conduct of Operations and the response to DOE Order 5480.19. These guidelines cover the following areas: (1) operations organization and administration; (2) shift routines and operating practices; (3) control area activities; (4) communications; (5) control of on-shift training; (6) investigation of abnormal events; (7) notifications; (8) control of equipment and system studies; (9) lockouts and tagouts; (10) independent verification; (11) log-keeping; (12) operations turnover; (13) operations aspects of facility process control (14) required reading; (15) timely orders to operators; (16) operations procedures; (17) operator aid posting; and (18) equipment sizing and labeling.

  5. Perspectives for future light source lattices incorporating yet uncommon magnets

    Directory of Open Access Journals (Sweden)

    S. C. Leemann

    2011-03-01

    Full Text Available Although octupoles, decapoles, and longitudinal gradient bending magnets (LGB have been studied for many years, they are not usually included in light source lattices. They can, however, be beneficial in order to realize ultralow emittance and attain sufficient dynamic aperture. We present methods for achieving ultralow emittance and discuss optimization of the nonlinear dynamics with multipoles. We demonstrate how control of amplitude-dependent tune shift makes octupoles a powerful tool for dynamic aperture optimization. Control of higher-order chromaticity by octupoles and decapoles is straightforward; however, since this turns out to be not quite as efficient in high-brightness lattices with low arc dispersion, we apply it to a conventional lattice to demonstrate the potential. This paper also illustrates how high-field LGBs can be used to build a compact, bright hard x-ray source. Finally, we demonstrate in detail the application of octupoles as integral components of the MAX IV 3 GeV storage ring lattice.

  6. Linac Coherent Light Source (LCLS) Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Nuhn, Heinz-Dieter

    2002-11-25

    The Stanford Linear Accelerator Center, in collaboration with Argonne National Laboratory, Brookhaven National Laboratory, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, have collaborated to create a conceptual design for a Free-Electron-Laser (FEL) R&D facility operating in the wavelength range 1.5-15 {angstrom}. This FEL, called the ''Linac Coherent Light Source'' (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. The first two-thirds of the SLAC linac are used for injection into the PEP-II storage rings. The last one-third will be converted to a source of electrons for the LCLS. The electrons will be transported to the SLAC Final Focus Test Beam (FFTB) Facility, which will be extended to house a 122-m undulator system. In passing through the undulators, the electrons will be bunched by the force of their own synchrotron radiation to produce an intense, spatially coherent beam of x-rays, tunable in energy from 0.8 keV to 8 keV. The LCLS will include two experiment halls as well as x-ray optics and infrastructure necessary to make use of this x-ray beam for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of constructing an x-ray FEL based on the SLAC linac.

  7. Feasibility of Ultraviolet Light Emitting Diodes as an Alternative Light Source for Photocatalysis

    Science.gov (United States)

    Levine, Langanf H.; Richards, Jeffrey T.; Soler, Robert; Maxik, Fred; Coutts, Janelle; Wheeler, Raymond M.

    2011-01-01

    The objective of this study was to determine whether ultraviolet light emitting diodes (UV-LEDs) could serve as an alternative photon source efficiently for heterogeneous photocatalytic oxidation (PCO). An LED module consisting of 12 high-power UV-A LEDs was designed to be interchangeable with a UV-A fluorescent black light blue (BLB) lamp in a Silica-Titania Composite (STC) packed bed annular reactor. Lighting and thermal properties were characterized to assess the uniformity and total irradiant output. A forward current of (I(sub F)) 100 mA delivered an average irradiance of 4.0 m W cm(exp -2), which is equivalent to the maximum output of the BLB, but the irradiance of the LED module was less uniform than that of the BLB. The LED- and BLB-reactors were tested for the oxidization of 50 ppmv ethanol in a continuous flow-through mode with 0.94 sec space time. At the same irradiance, the UV-A LED reactor resulted in a lower PCO rate constant than the UV-A BLB reactor (19.8 vs. 28.6 nM CO2 sec-I), and consequently lower ethanol removal (80% vs. 91%) and mineralization efficiency (28% vs. 44%). Ethanol mineralization increased in direct proportion to the irradiance at the catalyst surface. This result suggests that reduced ethanol mineralization in the LED- reactor could be traced to uneven irradiance over the photocatalyst, leaving a portion of the catalyst was under-irradiated. The potential of UV-A LEDs may be fully realized by optimizing the light distribution over the catalyst and utilizing their instantaneous "on" and "off' feature for periodic irradiation. Nevertheless, the current UV-A LED module had the same wall plug efficiency (WPE) of 13% as that of the UV-A BLB. These results demonstrated that UV-A LEDs are a viable photon source both in terms of WPE and PCO efficiency.

  8. Linac Coherent Light Source (LCLS) design study report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    The Stanford Linear Accelerator Center (SLAC), in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the self-amplified spontaneous emission (SASE) mode in the wavelength range 1.5--15 {angstrom}. This FEL, called Linac Coherent Light Source (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. In this report, the Design Team has established performance parameters for all the major components of the LCLS and developed a layout of the entire system. Chapter 1 is the Executive Summary. Chapter 2 (Overview) provides a brief description of each of the major sections of the LCLS, from the rf photocathode gun, through the experimental stations and electron beam dump. Chapter 3 describes the scientific case for the LCLS. Chapter 4 provides a review of the principles of the FEL physics that the LCLS is based on, and Chapter 5 discusses the choice of the system's physical parameters. Chapters 6 through 10 describe in detail each major element of the system. Chapters 11 through 13 respectively cover undulator controls, mechanical alignment, and radiation issues.

  9. Use of an alternative light source to assess strangulation victims.

    Science.gov (United States)

    Holbrook, Debra S; Jackson, M Christine

    2013-01-01

    Alternative light sources (ALSs) are commonly used at crime scenes and in forensic laboratories to collect evidence such as latent fingerprints, body fluids, hair, and fibers. This article describes the use of this technology to reveal soft tissue injuries that are not visible to the naked or unaided eye in patients who report strangulation. The value of this information to the medical, nursing, and judicial systems is discussed. The records of the 172 strangulation patients seen in our forensic nurse examiner program between 2009 and 2010 were reviewed. The SPEX Crimescope (SPEX Forensics, Edison, New Jersey) was used during the assessment of all of them. Ninety-three percent of the patients had no visible evidence of external injuries on physical examination. The ALS revealed positive findings of intradermal injuries in 98% of that group. Information obtained with ALS devices helps medical and nursing practitioners understand the gravity of patients' injuries, influences medical treatment decisions and follow-up care, and supports the prosecution of the perpetrators of crimes of violence. Educational programs about the application of ALS and the interpretation of its findings are valuable for medical, nursing, and other forensic disciplines.

  10. Handling high data rate detectors at Diamond Light Source

    Science.gov (United States)

    Pedersen, U. K.; Rees, N.; Basham, M.; Ferner, F. J. K.

    2013-03-01

    An increasing number of area detectors, in use at Diamond Light Source, produce high rates of data. In order to capture, store and process this data High Performance Computing (HPC) systems have been implemented. This paper will present the architecture and usage for handling high rate data: detector data capture, large volume storage and parallel processing. The EPICS area Detector frame work has been adopted to abstract the detectors for common tasks including live processing, file format and storage. The chosen data format is HDF5 which provides multidimensional data storage and NeXuS compatibility. The storage system and related computing infrastructure include: a centralised Lustre based parallel file system, a dedicated network and a HPC cluster. A well defined roadmap is in place for the evolution of this to meet demand as the requirements and technology advances. For processing the science data the HPC cluster allow efficient parallel computing, on a mixture of ×86 and GPU processing units. The nature of the Lustre storage system in combination with the parallel HDF5 library allow efficient disk I/O during computation jobs. Software developments, which include utilising optimised parallel file reading for a variety of post processing techniques, are being developed in collaboration as part of the Pan-Data EU Project (www.pan-data.eu). These are particularly applicable to tomographic reconstruction and processing of non crystalline diffraction data.

  11. Final Report, Photocathodes for High Repetition Rate Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, Ilan [Stony Brook University

    2014-04-20

    This proposal brought together teams at Brookhaven National Laboratory (BNL), Lawrence Berkeley National Laboratory (LBNL) and Stony Brook University (SBU) to study photocathodes for high repetition rate light sources such as Free Electron Lasers (FEL) and Energy Recovery Linacs (ERL). The work done under this grant comprises a comprehensive program on critical aspects of the production of the electron beams needed for future user facilities. Our program pioneered in situ and in operando diagnostics for alkali antimonide growth. The focus is on development of photocathodes for high repetition rate Free Electron Lasers (FELs) and Energy Recovery Linacs (ERLs), including testing SRF photoguns, both normal-conducting and superconducting. Teams from BNL, LBNL and Stony Brook University (SBU) led this research, and coordinated their work over a range of topics. The work leveraged a robust infrastructure of existing facilities and the support was used for carrying out the research at these facilities. The program concentrated in three areas: a) Physics and chemistry of alkali-antimonide cathodes b) Development and testing of a diamond amplifier for photocathodes c) Tests of both cathodes in superconducting RF photoguns and copper RF photoguns

  12. High Energy Density Science at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, R W

    2007-10-19

    High energy density science (HEDS), as a discipline that has developed in the United States from National Nuclear Security Agency (NNSA)-sponsored laboratory research programs, is, and will remain, a major component of the NNSA science and technology strategy. Its scientific borders are not restricted to NNSA. 'Frontiers in High Energy Density Physics: The X-Games of Contemporary Science' identified numerous exciting scientific opportunities in this field, while pointing to the need for a overarching interagency plan for its evolution. Meanwhile, construction of the first x-ray free-electron laser, the Office-of-Science-funded Linear Coherent Light Source-LCLS: the world's first free electron x-ray laser, with 100-fsec time resolution, tunable x-ray energies, a high rep rate, and a 10 order-of-magnitude increase in brightness over any other x-ray source--led to the realization that the scientific needs of NNSA and the broader scientific community could be well served by an LCLS HEDS endstation employing both short-pulse and high-energy optical lasers. Development of this concept has been well received in the community. NNSA requested a workshop on the applicability of LCLS to its needs. 'High Energy Density Science at the LCLS: NNSA Defense Programs Mission Need' was held in December 2006. The workshop provided strong support for the relevance of the endstation to NNSA strategic requirements. The range of science that was addressed covered a wide swath of the vast HEDS phase space. The unique possibilities provided by the LCLS in areas of intense interest to NNSA Defense Programs were discussed. The areas of focus included warm dense matter and equations of state, hot dense matter, and behavior of high-pressure materials under conditions of high strain-rate and extreme dynamic loading. Development of new and advanced diagnostic techniques was also addressed. This report lays out the relevant science, as brief summaries (Ch. II), expanded

  13. Classification of light sources and their interaction with active and passive environments

    CERN Document Server

    El-Dardiry, Ramy G S; Lagendijk, Ad

    2010-01-01

    The emission properties of a molecular light source depend on its optical and chemical environment. This dependence, however, is different for various light sources. We present a general classification of sources by introducing the concepts of Constant Amplitude and Constant Power Sources. The unforeseen consequences of this classification are illustrated for photonic studies by random laser experiments. Comparison of the experimental results with properly customized rate equations identifies the type of light source in the gain medium and an estimate for its quantum efficiency. Our results require a major revision of source studies in multiple scattering media.

  14. A new type of white light-emitting diode light source basing on fluorescent SiC

    DEFF Research Database (Denmark)

    Ou, Haiyan; Ou, Yiyu; Lu, Weifang

    Most of the commercial white light-emitting diode (LED) light sources are made from phosphor coated blue-emitting gallium nitride (GaN) chips. This type white LED light source always has tradeoff between luminous efficacy and color rendering index (CRI). Furthermore, yellow-emitting phosphor decays...... much faster than the semiconductor chip, so the white color will turn into bluish over the time. This paper will propose a new type white LED light source: using fluorescent silicon carbide (SiC) to take the place of phosphor. This new type LED has the following advantages: a) SiC is a wide bandgap...... semiconductor material , so it is stable; b) Fluorescent SiC has very wide emission spectrum, and it could generate white light with very high CRI; c) It is a better substrate than sapphire for the GaN growth in terms of lattice match and thermal conductivity. This paper will cover: the growth of fluorescent Si...

  15. Two-function light source in a FBG multi-point sensing system

    Institute of Scientific and Technical Information of China (English)

    HE Shi-ya; DENG Yan-hao; YU Yang; HU Shu-yang; GUAN Zheng

    2007-01-01

    In this paper, a two-function light source is recommended. It can both amplify the light power and demodulate the wavelength signal. Its output power is 1000 times as high as traditional broadband light source (BBS) and it can demodulate the signal by scanning wavelength in 30 nmof bandwidth range in the situation of 1550 nm central wavelength. This kind of light source effectively solves the problem of light energy supply in more-point measurement of FBG and simplifies the structure of sensing measurement.

  16. Advanced Light Source activity report 1996/97

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    Ten years ago, the Advanced Light Source (ALS) existed as a set of drawings, calculations, and ideas. Four years ago, it stored an electron beam for the first time. Today, the ALS has moved from those ideas and beginnings to a robust, third-generation synchrotron user facility, with eighteen beam lines in use, many more in planning or construction phases, and hundreds of users from around the world. Progress from concepts to realities is continuous as the scientific program, already strong in many diverse areas, moves in new directions to meet the needs of researchers into the next century. ALS staff members who develop and maintain the infrastructure for this research are similarly unwilling to rest on their laurels. As a result, the quality of the photon beams the authors deliver, as well as the support they provide to users, continues to improve. The ALS Activity Report is designed to share the results of these efforts in an accessible form for a broad audience. The Scientific Program section, while not comprehensive, shares the breadth, variety, and interest of recent research at the ALS. (The Compendium of User Abstracts and Technical Reports provides a more comprehensive and more technical view.) The Facility Report highlights progress in operations, ongoing accelerator research and development, and beamline instrumentation efforts. Although these Activity Report sections are separate, in practice the achievements of staff and users at the ALS are inseparable. User-staff collaboration is essential as they strive to meet the needs of the user community and to continue the ALS's success as a premier research facility.

  17. Shielding synchrotron light sources: Advantages of circular shield walls tunnels

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, S.L. [Design and Accelerator Operations Consulting, 568 Wintergreen Ct Ridge, NY 11961 (United States); Ghosh, V.J.; Breitfeller, M. [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2016-08-11

    Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produce significantly higher neutron component dose to the experimental floor than lower energy injection and ramped operations. High energy neutrons produced in the forward direction from thin target beam losses are a major component of the dose rate outside the shield walls of the tunnel. The convention has been to provide thicker 90° ratchet walls to reduce this dose to the beam line users. We present an alternate circular shield wall design, which naturally and cost effectively increases the path length for this forward radiation in the shield wall and thereby substantially decreasing the dose rate for these beam losses. This shield wall design will greatly reduce the dose rate to the users working near the front end optical components but will challenge the beam line designers to effectively utilize the longer length of beam line penetration in the shield wall. Additional advantages of the circular shield wall tunnel are that it's simpler to construct, allows greater access to the insertion devices and the upstream in tunnel beam line components, as well as reducing the volume of concrete and therefore the cost of the shield wall.

  18. Shielding synchrotron light sources: Advantages of circular shield walls tunnels

    Science.gov (United States)

    Kramer, S. L.; Ghosh, V. J.; Breitfeller, M.

    2016-08-01

    Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produce significantly higher neutron component dose to the experimental floor than lower energy injection and ramped operations. High energy neutrons produced in the forward direction from thin target beam losses are a major component of the dose rate outside the shield walls of the tunnel. The convention has been to provide thicker 90° ratchet walls to reduce this dose to the beam line users. We present an alternate circular shield wall design, which naturally and cost effectively increases the path length for this forward radiation in the shield wall and thereby substantially decreasing the dose rate for these beam losses. This shield wall design will greatly reduce the dose rate to the users working near the front end optical components but will challenge the beam line designers to effectively utilize the longer length of beam line penetration in the shield wall. Additional advantages of the circular shield wall tunnel are that it's simpler to construct, allows greater access to the insertion devices and the upstream in tunnel beam line components, as well as reducing the volume of concrete and therefore the cost of the shield wall.

  19. LNLS: light source, beamlines, end stations and scientific instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Vicentin, Flavio Cesar [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, SP (Brazil)

    2012-07-01

    Full text: The LNLS is operational since 1997 and has a second-generation light source with a 1,37GeV electron storage ring and 2,08 keV critical energy. Besides the storage ring there are various beamlines installed mainly in magnetic dipoles, however were opened three beamlines based in insertion devices, wiggler and undulator. The LNLS is now operating with 16 beamlines which are open to the external user community: 9 of them are dedicated to structural studies and the other 7 to spectroscopic techniques. The beamlines devoted to structural studies involve X-ray diffraction (XRD1, XRD2, XPD and XDS), small-angle X-ray scattering (SAXS1 and SAXS2), protein crystallography (MX1 and MX2) and X-ray fluorescence (XRF). The beamlines dedicated to spectroscopic studies are X-ray absorption fine structure (XAFS1, XAFS2 and DXAS), soft X-ray spectroscopy (SXS), spherical grating monochromator (SGM), plane grating monochromator (PGM) and toroidal grating monochromator (TGM). Two more beamlines are expected to begin their operation in 2012: X-ray tomography and infrared spectroscopy. Each beamline has its own characteristics in terms of photon energy range, flux, resolution and beam size, but many of the optical elements and instrumentation are common to various beamlines and the main are mirrors, monochromators (crystal and diffraction grating), slits and filters. For X-ray and VUV spectroscopy, several experimental techniques can be explored including XAS, XMCD, XMLD, XPS, AES, UPS, XEOL, reflectivity and PePiCo. For that, these beamlines share different end stations and instrumentation that can be easily installed and commissioned for attend a specific experiment. (author)

  20. Dielectric Wakefield Accelerator to drive the future FEL Light Source.

    Energy Technology Data Exchange (ETDEWEB)

    Jing, C.; Power, J.; Zholents, A. (Accelerator Systems Division (APS)); ( HEP); (LLC)

    2011-04-20

    X-ray free-electron lasers (FELs) are expensive instruments and a large part of the cost of the entire facility is driven by the accelerator. Using a high-energy gain dielectric wake-field accelerator (DWA) instead of the conventional accelerator may provide a significant cost saving and reduction of the facility size. In this article, we investigate using a collinear dielectric wakefield accelerator to provide a high repetition rate, high current, high energy beam to drive a future FEL x-ray light source. As an initial case study, a {approx}100 MV/m loaded gradient, 850 GHz quartz dielectric based 2-stage, wakefield accelerator is proposed to generate a main electron beam of 8 GeV, 50 pC/bunch, {approx}1.2 kA of peak current, 10 x 10 kHz (10 beamlines) in just 100 meters with the fill factor and beam loading considered. This scheme provides 10 parallel main beams with one 100 kHz drive beam. A drive-to-main beam efficiency {approx}38.5% can be achieved with an advanced transformer ratio enhancement technique. rf power dissipation in the structure is only 5 W/cm{sup 2} in the high repetition rate, high gradient operation mode, which is in the range of advanced water cooling capability. Details of study presented in the article include the overall layout, the transform ratio enhancement scheme used to increase the drive to main beam efficiency, main wakefield linac design, cooling of the structure, etc.

  1. Polymer and small molecule based hybrid light source

    Science.gov (United States)

    Choong, Vi-En; Choulis, Stelios; Krummacher, Benjamin Claus; Mathai, Mathew; So, Franky

    2010-03-16

    An organic electroluminescent device, includes: a substrate; a hole-injecting electrode (anode) coated over the substrate; a hole injection layer coated over the anode; a hole transporting layer coated over the hole injection layer; a polymer based light emitting layer, coated over the hole transporting layer; a small molecule based light emitting layer, thermally evaporated over the polymer based light emitting layer; and an electron-injecting electrode (cathode) deposited over the electroluminescent polymer layer.

  2. Current-voltage model of LED light sources

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2012-01-01

    Amplitude modulation is rarely used for dimming light-emitting diodes in polychromatic luminaires due to big color shifts caused by varying magnitude of LED driving current and nonlinear relationship between intensity of a diode and driving current. Current-voltage empirical model of light...

  3. Organic Light Emitting Device as a fluorescence spectroscopy's light source : one step towards the lab-on-a-chip device

    Science.gov (United States)

    Camou, S.; Kitamura, M.; Gouy, Jean-Philippe; Fujita, Hiroyuki; Arakawa, Yasuhiko; Fujii, Teruo

    2003-02-01

    Many papers were recently dedicated to the lab-on-a-chip applications, where all the basic elements should be integrated directly onto the microchip. The fluorescence spectroscopy is mostly used as a detection method due to its high reliability and sensitivity, but requires light source and photo-detector. For the first time, we then propose to use Organic material Light Emitting Diode (OLED) to supply a light source for the optical detection based on fluorescence spectroscopy. By combining this OLED with micro-fluidic channels patterned in PDMS layer, the integration of light source on the chip is then achieved. First, the ability of Organic Material to excite fluorescent response from dye is demonstrated. Then, some configurations are described in order to decrease the major drawbacks that have to be solved before applying such kind of devices.

  4. CURRENT STATE OF AUTOMOTIVE LIGHTING EQUIPMENT WITH NON-REPLACEABLE LIGHT SOURCES ON BASIS OF LIGHT-EMITTING DIODE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    S. Sernov

    2012-01-01

    Full Text Available The paper contains information on the current state of automotive lighting equipment. Different designs of automotive lighting devices, their merits and demerits are described in the paper. The paper includes a substantiation of expediency of developing light-emitting diode lighting and proposes recommendations about optimization of their design.

  5. Operation of the Metrology Light Source as a primary radiation source standard

    Directory of Open Access Journals (Sweden)

    Roman Klein

    2008-11-01

    Full Text Available The Metrology Light Source (MLS, the new electron storage ring of the Physikalisch-Technische Bundesanstalt (PTB located in Berlin, is dedicated to metrology and technological developments in the UV and extreme UV spectral range as well as in the IR and THz region. The MLS can be operated at any electron beam energy between 105 and 630 MeV and at electron beam currents varying from 1 pA (one stored electron up to 200 mA. Moreover, it is optimized for the generation of coherent synchrotron radiation in the far IR/THz range. Of special interest for PTB is the operation of the MLS as a primary radiation source standard from the near IR up to the soft x-ray region. Therefore, the MLS is equipped with all the instrumentation necessary to measure the storage ring parameters and geometrical parameters needed for the calculation of the spectral photon flux according to the Schwinger theory with low uncertainty.

  6. A new small-package super-continuum light source for optical coherence tomography

    Science.gov (United States)

    Meissner, Sven; Cimalla, Peter; Fischer, Björn; Taudt, Christopher; Baselt, Tobias; Hartmann, Peter; Koch, Edmund

    2013-03-01

    Broadband light sources provide a significant benefit for optical coherence tomography (OCT) imaging concerning the axial resolution. Light sources with bandwidths over 200 nm result in an axial resolution up to 2 microns. Such broad band OCT imaging can be achieved utilizing super continuum (SC) light sources. The main important disadvantage of commercial SC light sources is the overall size and the high costs. Therefore, the use of SC light sources in small OCT setups and applications is limited. We present a new small housing and costeffective light source, which is suitable for OCT imaging. The used light source has dimensions of 110 x 160 x 60 mm and covers a wavelength range from 390 nm up to 2500 nm. The light source was coupled in a dual band OCT system. The light is guided into the interferometer and split in reference and sample beam. The superimposed signal is guided to the spectrometer unit, which consists of two spectrometers. This spectrometer system separates the light. One band centered at 800 nm with a full bandwidth of 176 nm and a second band centered at 1250 nm with a full spectral width of 300 nm was extracted. The 800 nm interference signal is detected by a silicon line scan camera and the 1250 nm signal by an indium gallium arsenide linear image sensor. In this test measurement a plastic foil was used as a sample, which is composed of several plastic film layers. Three dimensional images were acquired simultaneous with the dual band OCT setup. The images were acquired at an A-scan rate of 1 kHz. The 1 kHz A-line rate was chosen because so far the optical power of the light source is not optimal for high speed OCT imaging. The source provides 2 mW in the range of 390 nm to 800 nm and 25 mW in the range from 390 nm to 1650 nm. Furthermore, we coupled the light source by a 50:50 optical fiber coupler, which also reduces the overall optical power of the light source within the OCT setup. Nevertheless, we demonstrated that this new small

  7. 49 CFR Appendix A to Part 564 - Information To Be Submitted for Replaceable Light Sources

    Science.gov (United States)

    2010-10-01

    ... information required by paragraphs A, B, and C of this section I for light sources using a resistive type... 49 Transportation 6 2010-10-01 2010-10-01 false Information To Be Submitted for Replaceable Light Sources A Appendix A to Part 564 Transportation Other Regulations Relating to Transportation (Continued...

  8. 21 CFR 874.4350 - Ear, nose, and throat fiberoptic light source and carrier.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear, nose, and throat fiberoptic light source and... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4350 Ear, nose, and throat fiberoptic light source and carrier. (a) Identification. An ear, nose, and...

  9. lightsources.org: An Internet Site for Light SourceCommunication

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Art

    2004-10-04

    Research at the world's accelerator- (storage-ring and linac) based light sources is one of the most dynamic and rapidly growing fields of science. It frequently results in direct benefits to society, thereby demonstrating the value of the research with very concrete examples, but this is not widely understood or appreciated outside of the immediate user community. Our growing group of light source communicators from facilities in Europe, Asia, and the Americas, inspired by the Interactions.org Web site created by high-energy (elementary-particle)physics communicators, concluded that a light source community Web site (lightsources.org) would be the best tool for establishing effective collaboration between the communications offices of the world's light sources and to maximize the impact of our efforts. We envision lightsources.org to serve as a one-stop-shopping site for information about all aspects of light sources and the research they make possible. Audiences to be served include science communicators, the press, policymakers, the light source community, the wider scientific community, the science-interested public, and students and educators. Our proposal has been sent to the world's light source facility directors by J. Murray Gibson (APS) and William G. Stirling (ESRF). As a result,light sources.org is now being supported by a growing list of facilities from Europe, North America, and Asia. We hope to launch lightsources.org before the end of 2004.

  10. Investigation of a scanning laser projector as an energy-efficient light source in plant production

    NARCIS (Netherlands)

    Murase, Haruhiko; Helm, van der Bob; Oke, Satoshi

    2015-01-01

    The energy costs for artificial lighting in plant factories are very high, but may be decreased by introducing more efficient light sources. Light absorption in plants takes place in the order of a femtosecond, while the chemical reactions for carbon fixation of 5 milliseconds are limiting the

  11. Optical coupling of flexible microstructured organic light sources for automotive applications

    NARCIS (Netherlands)

    Melpignano, P.; Sinesi, S.; Rotaris, G.; Antonipieri, M.; Cicoira, F.; Loi, M.A.; Muccini, M.; Zamboni, R.; Gale, M.T.; Westenhöfer, S.

    2003-01-01

    In this paper, we report on modelling and processing of customised optical patterns coupled with microstructured large area organic light emitting device (OLED) sources for automotive lighting. Different approaches for the optical control of the light emitted from an OLED are discussed and compared

  12. Inferred motion perception of light sources in 3D scenes is color-blind.

    Science.gov (United States)

    Gerhard, Holly E; Maloney, Laurence T

    2013-01-01

    In everyday scenes, the illuminant can vary spatially in chromaticity and luminance, and change over time (e.g. sunset). Such variation generates dramatic image effects too complex for any contemporary machine vision system to overcome, yet human observers are remarkably successful at inferring object properties separately from lighting, an ability linked with estimation and tracking of light field parameters. Which information does the visual system use to infer light field dynamics? Here, we specifically ask whether color contributes to inferred light source motion. Observers viewed 3D surfaces illuminated by an out-of-view moving collimated source (sun) and a diffuse source (sky). In half of the trials, the two sources differed in chromaticity, thereby providing more information about motion direction. Observers discriminated light motion direction above chance, and only the least sensitive observer benefited slightly from the added color information, suggesting that color plays only a very minor role for inferring light field dynamics.

  13. Inferred Motion Perception of Light Sources in 3D Scenes is Color-Blind

    Directory of Open Access Journals (Sweden)

    Holly E. Gerhard

    2013-04-01

    Full Text Available In everyday scenes, the illuminant can vary spatially in chromaticity and luminance, and change over time (e.g. sunset. Such variation generates dramatic image effects too complex for any contemporary machine vision system to overcome, yet human observers are remarkably successful at inferring object properties separately from lighting, an ability linked with estimation and tracking of light field parameters. Which information does the visual system use to infer light field dynamics? Here, we specifically ask whether color contributes to inferred light source motion. Observers viewed 3D surfaces illuminated by an out-of-view moving collimated source (sun and a diffuse source (sky. In half of the trials, the two sources differed in chromaticity, thereby providing more information about motion direction. Observers discriminated light motion direction above chance, and only the least sensitive observer benefited slightly from the added color information, suggesting that color plays only a very minor role for inferring light field dynamics.

  14. Potential sustainable energy source: Pheroid™ with incorporated light harvesting materials

    CSIR Research Space (South Africa)

    Smit, Jacoba E

    2010-09-01

    Full Text Available . In the photosynthetic system light energy is absorbed by antenna chlorophylls and this energy is then passed onto a reaction centre chlorophyll molecule where charge separation occurs [1] in less than 100 ps and at about 95% efficiency [2]. It has been shown...-based combinations, which enables the production of small, elastic artificial vesicles, called Pheroid™. Previous work has shown that photosynthetic light harvesting material can be incorporated into the Pheroid™ (Figure 1). Figure 1: Examples of photosynthetic...

  15. Contributions of artificial lighting sources on light pollution in Hong Kong measured through a night sky brightness monitoring network

    CERN Document Server

    Pun, Chun Shing Jason; Leung, Wai Yan; Wong, Chung Fai

    2014-01-01

    Light pollution is a form of environmental degradation in which excessive artificial outdoor lighting, such as street lamps, neon signs, and illuminated signboards, affects the natural environment and the ecosystem. Poorly designed outdoor lighting not only wastes energy, money, and valuable Earth resources, but also robs us of our beautiful night sky. Effects of light pollution on the night sky can be evaluated by the skyglow caused by these artificial lighting sources, through measurements of the night sky brightness (NSB). The Hong Kong Night Sky Brightness Monitoring Network (NSN) was established to monitor in detail the conditions of light pollution in Hong Kong. Monitoring stations were set up throughout the city covering a wide range of urban and rural settings to continuously measure the variations of the NSB. Over 4.6 million night sky measurements were collected from 18 distinct locations between May 2010 and March 2013. This huge dataset, over two thousand times larger than our previous survey, for...

  16. Paul Scherrer Institute Scientific Report 1998. Volume VII: Swiss Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Weyer, Heinz Josef; Bugmann, Marlen; Neuhaus, Sibylle [eds.

    1999-09-01

    The Swiss Light Source (SLS) is a medium energy range light source that also provides light with high brilliance in the regime of hard X-rays. It is being constructed at PSI and scheduled to be operational in 2001. A series of new features that were adopted for the design and operation of this machine, is described in this annual report for 1998 figs., tabs., refs.

  17. National synchrotron light source in the infra-red region

    Energy Technology Data Exchange (ETDEWEB)

    Williams, G.P.

    1981-01-01

    A discussion of the utilization of the NSLS in the 1 to 100 micron infra-red spectral region is presented. A comparison is made of the respective brightnesses of the NSLS and of black-body sources. The way in which each source may be utilized with a monochromator is discussed and comparative exit slit brightnesses are calculated for selected cases.

  18. Light intensity and quality from sole-source light-emitting diodes impact growth, morphology, and nutrient content of Brassica microgreens

    Science.gov (United States)

    Multi-layer vertical production systems using sole-source (SS) lighting can be used for microgreen production; however, traditional SS lighting can consume large amounts of electrical energy. Light-emitting diodes (LEDs) offer many advantages over conventional light sources including: high photoelec...

  19. Influence of light sources on the migration of polymorphonuclear leukocytes

    Science.gov (United States)

    DellaVecchia, Michael A.; Beard, Richard B.; Dai, Xiaoyan

    1995-05-01

    In the process of inflammation, leukocytes must travel from the intraluminal space of the capillary to the interstitial space in order to reach the site of the inflammation. The two major populations of mature human leukocytes based on the morphology are the polymorphonuclear leukocytes (PMN), and mononuclear leukocytes (MNL). Previous research on PMNs and MNLs at the Biomedical Engineering and Science Institute of Drexel University have shown that their migration can be markedly enhanced by excitation with electric and magnetic fields. This presentation demonstrates that the migration of PMNs under excitation of photons is enhanced in the red light region of (lambda) equals 660 nm and inhibited in the green light region of (lambda) equals 565 nm. There is an intensity threshold at which red light enhances migration and an intensity threshold at which green light inhibits migration. In these experiments the Boyden technique was used with the distance of the cell migration through a cellulose filter measured in terms of the leading edge. The comparison of the relative value of the distance to cell migration under a light to cell migration without a light stimulus was recorded as a cytokinetic index, K.I.. K.I. is a measure of the cytokinesis which is the progress of the cell movement in which the migration is enhanced by substances in the cell environment irrespective of a concentration gradient. The cytotactic index is a measure of cytotaxis which is the directional movement along a chemical gradient formed by a chemotactic factor. A Russian pulsed commercial laser biostimulator in the near infrared wavelength above an intensity threshold enhances PMN migration. Intermittent green and red stimulators below the intensity threshold markedly influence the cytokinetic index of PMNs while above the intensity threshold, this influence is deminished.

  20. Mono-energy coronary angiography with a compact light source

    Science.gov (United States)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noël, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-03-01

    While conventional x-ray tube sources reliably provide high-power x-ray beams for everyday clinical practice, the broad spectra that are inherent to these sources compromise the diagnostic image quality. For a monochromatic x-ray source on the other hand, the x-ray energy can be adjusted to optimal conditions with respect to contrast and dose. However, large-scale synchrotron sources impose high spatial and financial demands, making them unsuitable for clinical practice. During the last decades, research has brought up compact synchrotron sources based on inverse Compton scattering, which deliver a highly brilliant, quasi-monochromatic, tunable x-ray beam, yet fitting into a standard laboratory. One application that could benefit from the invention of these sources in clinical practice is coronary angiography. Being an important and frequently applied diagnostic tool, a high number of complications in angiography, such as renal failure, allergic reaction, or hyperthyroidism, are caused by the large amount of iodine-based contrast agent that is required for achieving sufficient image contrast. Here we demonstrate monochromatic angiography of a porcine heart acquired at the MuCLS, the first compact synchrotron source. By means of a simulation, the CNR in a coronary angiography image achieved with the quasi-mono-energetic MuCLS spectrum is analyzed and compared to a conventional x-ray-tube spectrum. The results imply that the improved CNR achieved with a quasi-monochromatic spectrum can allow for a significant reduction of iodine contrast material.

  1. Artificial algae algorithm with multi-light source for numerical optimization and applications.

    Science.gov (United States)

    Uymaz, Sait Ali; Tezel, Gulay; Yel, Esra

    2015-12-01

    Artificial algae algorithm (AAA), which is one of the recently developed bio-inspired optimization algorithms, has been introduced by inspiration from living behaviors of microalgae. In AAA, the modification of the algal colonies, i.e. exploration and exploitation is provided with a helical movement. In this study, AAA was modified by implementing multi-light source movement and artificial algae algorithm with multi-light source (AAAML) version was established. In this new version, we propose the selection of a different light source for each dimension that is modified with the helical movement for stronger balance between exploration and exploitation. These light sources have been selected by tournament method and each light source are different from each other. This gives different solutions in the search space. The best of these three light sources provides orientation to the better region of search space. Furthermore, the diversity in the source space is obtained with the worst light source. In addition, the other light source improves the balance. To indicate the performance of AAA with new proposed operators (AAAML), experiments were performed on two different sets. Firstly, the performance of AAA and AAAML was evaluated on the IEEE-CEC'13 benchmark set. The second set was real-world optimization problems used in the IEEE-CEC'11. To verify the effectiveness and efficiency of the proposed algorithm, the results were compared with other state-of-the-art hybrid and modified algorithms. Experimental results showed that the multi-light source movement (MLS) increases the success of the AAA.

  2. Lasers or light sources for treating port-wine stains

    DEFF Research Database (Denmark)

    Faurschou, Annesofie; Olesen, Anne Braae; Leonardi-Bee, Jo;

    2011-01-01

    Port-wine stains are birthmarks caused by malformations of blood vessels in the skin. Port-wine stains manifest themselves in infancy as a flat, red mark and do not regress spontaneously but may, if untreated, become darker and thicker in adult life. The profusion of various lasers and light...

  3. Microwave Oven Experiments with Metals and Light Sources

    Science.gov (United States)

    Vollmer, Michael; Mollmann, Klaus-Peter; Karstadt, Detlef

    2004-01-01

    "Don't put metal objects in the microwave" is common safety advice. But why? Here we describe demonstration experiments involving placing household metallic objects in a microwave oven. These allow a better understanding of the interaction of microwaves with materials. Light bulbs and discharge lamps can also be used in instructive demonstrations.

  4. Microwave Oven Experiments with Metals and Light Sources

    Science.gov (United States)

    Vollmer, Michael; Mollmann, Klaus-Peter; Karstadt, Detlef

    2004-01-01

    "Don't put metal objects in the microwave" is common safety advice. But why? Here we describe demonstration experiments involving placing household metallic objects in a microwave oven. These allow a better understanding of the interaction of microwaves with materials. Light bulbs and discharge lamps can also be used in instructive demonstrations.

  5. Playing the tricks of numbers of light sources

    Science.gov (United States)

    Chen, Huanyang; Xu, Yadong; Li, Hui; Tyc, Tomáš

    2013-09-01

    Transformation optics has demonstrated its ability to design various novel devices, for example, to change objects' sizes, positions or even shapes. This time we come to another magical manipulation: to change the numbers of sources. In this paper, we will design a new class of gradient index lenses from multivalued optical conformal mapping. We shall call them the conformal lenses. Such lenses can make one active source appear omnidirectionally as two (or many) in-phase sources, each interfering with others. As a self-interference phenomenon, this has not been discussed before. Meanwhile, they can transform multiple in-phase sources into one. Other intriguing illusion effects are also demonstrated. Based on the Riemann sheet analysis, the physics mechanism of such effects are well explained. Finally, we apply transmutation methods to design lenses without any singular material parameters.

  6. In situ calibration of a light source in a sensor device

    Energy Technology Data Exchange (ETDEWEB)

    Okandan, Murat; Serkland, Darwin k.; Merchant, Bion J.

    2015-12-29

    A sensor device is described herein, wherein the sensor device includes an optical measurement system, such as an interferometer. The sensor device further includes a low-power light source that is configured to emit an optical signal having a constant wavelength, wherein accuracy of a measurement output by the sensor device is dependent upon the optical signal having the constant wavelength. At least a portion of the optical signal is directed to a vapor cell, the vapor cell including an atomic species that absorbs light having the constant wavelength. A photodetector captures light that exits the vapor cell, and generates an electrical signal that is indicative of intensity of the light that exits the vapor cell. A control circuit controls operation of the light source based upon the electrical signal, such that the light source emits the optical signal with the constant wavelength.

  7. White LED compared with other light sources: age-dependent photobiological effects and parameters for evaluation.

    Science.gov (United States)

    Rebec, Katja Malovrh; Klanjšek-Gunde, Marta; Bizjak, Grega; Kobav, Matej B

    2015-01-01

    Ergonomic science at work and living places should appraise human factors concerning the photobiological effects of lighting. Thorough knowledge on this subject has been gained in the past; however, few attempts have been made to propose suitable evaluation parameters. The blue light hazard and its influence on melatonin secretion in age-dependent observers is considered in this paper and parameters for its evaluation are proposed. New parameters were applied to analyse the effects of white light-emitting diode (LED) light sources and to compare them with the currently applied light sources. The photobiological effects of light sources with the same illuminance but different spectral power distribution were determined for healthy 4-76-year-old observers. The suitability of new parameters is discussed. Correlated colour temperature, the only parameter currently used to assess photobiological effects, is evaluated and compared to new parameters.

  8. Modelling of a laser-pumped light source for endoscopic surgery

    Science.gov (United States)

    Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.

    2008-09-01

    A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.

  9. Effect of color temperature of light sources on slow-wave sleep.

    Science.gov (United States)

    Kozaki, Tomoaki; Kitamura, Shingo; Higashihara, Yuichi; Ishibashi, Keita; Noguchi, Hiroki; Yasukouchi, Akira

    2005-03-01

    In order to examine whether the spectral compositions of light source may affect sleep quality, sleep architecture under different color temperatures of light sources was evaluated. Seven healthy males were exposed to the light sources of different color temperatures (3000 K, 5000 K and 6700 K) for 6.5 h before sleep. The horizontal illuminance level was kept at 1000 lux. Subjects slept on a bed in near darkness (light, and polysomnograms recorded the sleep parameters. In the early phase of the sleep period, the amount of stage-4 sleep (S4-sleep) was significantly attenuated under the higher color temperature of 6700 K compared with the lower color temperature of 3000 K. Present findings suggest that light sources with higher color temperatures may affect sleep quality in a view that S4-sleep period is important for sleep quality.

  10. High-Efficiency Nitride-Base Photonic Crystal Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    James Speck; Evelyn Hu; Claude Weisbuch; Yong-Seok Choi; Kelly McGroddy; Gregor Koblmuller; Elison Matioli; Elizabeth Rangel; Fabian Rol; Dobri Simeonov

    2010-01-31

    The research activities performed in the framework of this project represent a major breakthrough in the demonstration of Photonic Crystals (PhC) as a competitive technology for LEDs with high light extraction efficiency. The goals of the project were to explore the viable approaches to manufacturability of PhC LEDS through proven standard industrial processes, establish the limits of light extraction by various concepts of PhC LEDs, and determine the possible advantages of PhC LEDs over current and forthcoming LED extraction concepts. We have developed three very different geometries for PhC light extraction in LEDs. In addition, we have demonstrated reliable methods for their in-depth analysis allowing the extraction of important parameters such as light extraction efficiency, modal extraction length, directionality, internal and external quantum efficiency. The information gained allows better understanding of the physical processes and the effect of the design parameters on the light directionality and extraction efficiency. As a result, we produced LEDs with controllable emission directionality and a state of the art extraction efficiency that goes up to 94%. Those devices are based on embedded air-gap PhC - a novel technology concept developed in the framework of this project. They rely on a simple and planar fabrication process that is very interesting for industrial implementation due to its robustness and scalability. In fact, besides the additional patterning and regrowth steps, the process is identical as that for standard industrially used p-side-up LEDs. The final devices exhibit the same good electrical characteristics and high process yield as a series of test standard LEDs obtained in comparable conditions. Finally, the technology of embedded air-gap patterns (PhC) has significant potential in other related fields such as: increasing the optical mode interaction with the active region in semiconductor lasers; increasing the coupling of the incident

  11. Optical-Fiber Fluorosensors With Polarized Light Sources

    Science.gov (United States)

    Egalon, Claudio O.; Rogowski, Robert S.

    1995-01-01

    Chemiluminescent and/or fluorescent molecules in optical-fiber fluorosensors oriented with light-emitting dipoles along transverse axis. Sensor of proposed type captures greater fraction of chemiluminescence or fluorescence and transmits it to photodetector. Transverse polarization increases sensitivity. Basic principles of optical-fiber fluorosensors described in "Making Optical-Fiber Chemical Sensors More Sensitive" (LAR-14525), "Improved Optical-Fiber Chemical Sensors" (LAR-14607), and "Improved Optical-Fiber Temperature Sensors" (LAR-14647).

  12. Optical-Fiber Fluorosensors With Polarized Light Sources

    Science.gov (United States)

    Egalon, Claudio O.; Rogowski, Robert S.

    1995-01-01

    Chemiluminescent and/or fluorescent molecules in optical-fiber fluorosensors oriented with light-emitting dipoles along transverse axis. Sensor of proposed type captures greater fraction of chemiluminescence or fluorescence and transmits it to photodetector. Transverse polarization increases sensitivity. Basic principles of optical-fiber fluorosensors described in "Making Optical-Fiber Chemical Sensors More Sensitive" (LAR-14525), "Improved Optical-Fiber Chemical Sensors" (LAR-14607), and "Improved Optical-Fiber Temperature Sensors" (LAR-14647).

  13. User evaluation of eight led light sources with different special colour rendering indices R9

    DEFF Research Database (Denmark)

    Markvart, Jakob; Iversen, Anne; Logadottir, Asta

    2013-01-01

    In this study we evaluated the influence of the special colour rendering index R9 on subjective red colour perception and Caucasian skin appearance among untrained test subjects. The light sources tested are commercially available LED based light sources with similar correlated colour temperature...... and general colour rendering index, but with varying R9. It was found that the test subjects in general are more positive towards light sources with higher R9. The shift from a majority of negative responses to a majority of positive responses is found to occur at R9 values of ~20....

  14. USER EVALUATION OF EIGHT LED LIGHT SOURCES WITH DIFFERENTSPECIAL COLOUR RENDERING INDICES R9

    DEFF Research Database (Denmark)

    Markvart, Jakob; Iversen, Anne; Logadóttir, Ásta;

    2013-01-01

    In this study we evaluated the influence of the special colour rendering index R9 on subjective red colour perception and Caucasian skin appearance among untrained test subjects. The light sources tested are commercially available LED based light sources with similar correlated colour temperature...... and general colour rendering index, but with varying R9. It was found that the test subjects in general are more positive towards light sources with higher R9. The shift from a majority of negative responses to a majority of positive responses is found to occur at R9 values of ~20....

  15. Optical Systems for the Fourth Generation Light Source, 4GLS

    CERN Document Server

    Quinn, Frances; MacDonald, Mike; Roper, Mark

    2004-01-01

    4GLS is a multi-user, multi-source facility proposed for construction at Daresbury Laboratory in the UK. By exploiting super-conducting linac technology with energy recovery, it will combine three free electron lasers and a range of conventional synchrotron radiation sources covering the THz to SXR region. The facility will provide femtosecond pulses at high repetition rate, with the FELs delivering GW power in the VUV and XUV region. This paper discusses the options and challenges for the optical systems associated with the suite of photon sources. The beamlines will need to operate both independently and in flexible, synchronised combinations. Together with the requirements for preserving the ultra-bright, fast pulse properties, this places unique demands on the design, layout and operational modes. The paper summarises current technical achievements and identifies the research and development necessary before detailed design of the 4GLS optical systems.

  16. Dazzling new light source opens at Stanford synchrotron radiation laboratory

    CERN Multimedia

    2004-01-01

    SPEAR3, the Stanford Positron Electron Asymmetric Ring, was formally opened at a dedication ceremony at the Stanford Linear Accelerator Center on Jan. 29. It incorporates the latest technology to make it competitive with the best synchrotron sources in the world (1/2 page)

  17. Development of a clockwork light source to enable cervical inspection by village health workers

    Directory of Open Access Journals (Sweden)

    Steventon Richard

    2002-12-01

    Full Text Available Abstract Background Cervical cancer can often be prevented by screening and may be curable if identified and treated in its early stages. However, 80% of new cases occur in less-developed countries where cervical cancer screening programmes are small-scale or non-existent. This is a human tragedy of great proportion, with many of those affected being young mothers. There is some evidence that cancerous or precancerous lesions may be detected by visual inspection with acetic acid (VIA and field studies indicate that this technique is effective, safe and acceptable to women. However, the provision of a light source for inspection of the cervix presents a major problem in less-developed countries, where candles and torches often provide the only means of illumination. Our objective was to develop a light source based on clockwork technology, that required no batteries or external power source. Methods We adapted the design of a commercially available clockwork torch to provide a light source for cervical inspection. The light source was then tested under laboratory conditions in a comparison with other illumination methods typically used in this application. Results The light source gave illuminance levels greater than those produced by any other method tested, and also had considerable advantages in terms of ease of use and safety. Conclusion This design is small, compact, effective and safe to use and promises a better and more affordable means of visualising the cervix. Further field trials of VIA are now required which incorporate this light source.

  18. A holographic display system based on DMD using LED as light source

    Science.gov (United States)

    Su, Ping; Cheng, Bingchao; Cao, Wenbo; Ma, Jianshe; Cao, Liangcai

    2016-09-01

    Digital Micro-mirror Device (DMD) is an important tool in holographic display owning high-speed refresh rate and good diffraction efficiency. However, the reconstruction light source has great impact to image quality. A new holographic display system based on DMD for using light-emitting diodes (LEDs), is proposed in this paper. LEDs are chosen as light source to replace the laser, since it can reduce the speckle noise effectively, which is caused by both temporal and spatial coherence of laser. In order to solve the problem using LED as DMD holographic display light source, the characteristics of DMD as the display device for holographic displays are studied. An aspheric collimator for LED is used to improve the optical efficiency. A spatial filter is used to improve the coherence. The experimental results show that this lighting system has a good display quality.

  19. 2-10 μm Mid-infrared Supercontinuum Light Sources

    DEFF Research Database (Denmark)

    Petersen, Christian Rosenberg; Møller, Uffe Visbech

    and using the light in different applications. This dissertation presents the past three years of my work with developing an alternative light source that has the broad spectral bandwidth of a lamp, and high power focused in a tight spot similar to a laser. Such a mid‐infrared light source can be achieved...... of the spectrum, is of interest because almost all molecules display distinct absorption fingerprints in this region. Current instrumentation however relies on thermal light sources, much like the wellknown incandescent light bulb, which has very limited brightness and limited possibilities for manipulating...... as well as experimental and numerical results. Several different configurations of lasers and fibers are investigated, together with techniques for increasing the power, such as imprinting of anti‐reflective structures and reducing the diameter of the fiber to increase the nonlinearity and thus efficiency...

  20. SIMEX: Simulation of Experiments at Advanced Light Sources

    CERN Document Server

    Fortmann-Grote, C; Briggs, R; Bussmann, M; Buzmakov, A; Garten, M; Grund, A; Hübl, A; Hauff, S; Joy, A; Jurek, Z; Loh, N D; Rüter, T; Samoylova, L; Santra, R; Schneidmiller, E A; Sharma, A; Wing, M; Yakubov, S; Yoon, C H; Yurkov, M V; Ziaja, B; Mancuso, A P

    2016-01-01

    Realistic simulations of experiments at large scale photon facilities, such as optical laser laboratories, synchrotrons, and free electron lasers, are of vital importance for the successful preparation, execution, and analysis of these experiments investigating ever more complex physical systems, e.g. biomolecules, complex materials, and ultra-short lived states of highly excited matter. Traditional photon science modelling takes into account only isolated aspects of an experiment, such as the beam propagation, the photon-matter interaction, or the scattering process, making idealized assumptions about the remaining parts, e.g.\\ the source spectrum, temporal structure and coherence properties of the photon beam, or the detector response. In SIMEX, we have implemented a platform for complete start-to-end simulations, following the radiation from the source, through the beam transport optics to the sample or target under investigation, its interaction with and scattering from the sample, and its registration in...

  1. Characterization of germanium linear kinoform lenses at Diamond Light Source.

    Science.gov (United States)

    Alianelli, L; Sawhney, K J S; Tiwari, M K; Dolbnya, I P; Stevens, R; Jenkins, D W K; Loader, I M; Wilson, M C; Malik, A

    2009-05-01

    The unprecedented brilliance achieved by third-generation synchrotron sources and the availability of improved optics have opened up new opportunities for the study of materials at the micrometre and nanometre scale. Focusing the synchrotron radiation to smaller and smaller beams is having a huge impact on a wide research area at synchrotrons. The key to the exploitation of the improved sources is the development of novel optics that deliver narrow beams without loss of brilliance and coherence. Several types of synchrotron focusing optics are successfully fabricated using advanced miniaturization techniques. Kinoform refractive lenses are being developed for hard X-ray beamlines, and the first test results at Diamond are discussed in this paper.

  2. Effects and Control of the Correlation Properties of Light Sources

    Science.gov (United States)

    1990-05-01

    frequency of interest. The mutual coherence function is related by a linear transform to the cross- spectral density function which describes the...Another important note here is that although there exists a simple relationship between the mutual coherence function and the cross- spectral density function , the...homogeneous, planar, secondary source can be characterized by a cross- spectral density function given by16 W(r,r 2 ;o) = G(r1 - r2 ;o) , (1.2.1) where

  3. National synchrotron light source. [Annual report], October 1, 1992--September 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Rothman, E.Z.; Hulbert, S.L.; Lazarz, N.M. [eds.

    1994-04-01

    This report contains brief discussions on the research being conducted at the National Synchrotron Light source. Some of the topics covered are: X-ray spectroscopy; nuclear physics; atomic and molecular science; meetings and workshops; operations; and facility improvements.

  4. Biomass and pigments production in photosynthetic bacteria wastewater treatment: effects of light sources.

    Science.gov (United States)

    Zhou, Qin; Zhang, Panyue; Zhang, Guangming

    2015-03-01

    This study is aimed at enhancing biomass and pigments production together with pollution removal in photosynthetic bacteria (PSB) wastewater treatment via different light sources. Red, yellow, blue, white LED and incandescent lamp were used. Results showed different light sources had great effects on the PSB. PSB had the highest biomass production, COD removal and biomass yield with red LED. The corresponding biomass, COD removal and biomass yield reached 2580 mg/L, 88.6% and 0.49 mg-biomass/mg-COD-removal, respectively. The hydraulic retention time of wastewater treatment could be shortened to 72 h with red LED. Mechanism analysis showed higher ATP was produced with red LED than others. Light sources could significantly affect the pigments production. The pigments productions were greatly higher with LED than incandescent lamp. Yellow LED had the highest pigments production while red LED produced the highest carotenoid/bacteriochlorophyll ratio. Considering both efficiency and energy cost, red LED was the optimal light source.

  5. Design and Optimisation Strategies of Nonlinear Dynamics for Diffraction Limited Synchrotron Light Source

    CERN Document Server

    Bartolini, R.

    2016-01-01

    This paper introduces the most recent achievements in the control of nonlinear dynamics in electron synchrotron light sources, with special attention to diffraction limited storage rings. Guidelines for the design and optimization of the magnetic lattice are reviewed and discussed.

  6. Vacuum Ultraviolet Xenon Excimer Light Source Excited by a Pulsed Jet Discharge

    National Research Council Canada - National Science Library

    Eiji FUTAGAMI; Toshiaki TAKADA; Junji KAWANAKA; Shoichi KUBODERA; Wataru SASAKI; Kou KUROSAWA; Kenichi MITSUHASHI; Tatsushi IGARASHI

    1995-01-01

      We have developed a new xenon excimer light source in vacuum ultraviolet (VUV). The use of a pulsed gas jet discharge realized efficient cluster excitation and spatially localized emission in VUV with an extremely long pulse duration...

  7. Microdischarge Array Flexible Light Source for High-Efficiency Irradiation of Spaced-Based Crops Project

    Data.gov (United States)

    National Aeronautics and Space Administration — It is desirable to develop a high-efficiency lighting source for large-area irradiation of space-based crops. The key requirements for such a system include high...

  8. Local transverse coupling impedance measurements in a synchrotron light source from turn-by-turn acquisitions

    National Research Council Canada - National Science Library

    Carlà, Michele; Benedetti, Gabriele; Günzel, Thomas; Iriso, Ubaldo; Martí, Zeus

    2016-01-01

    .... Beam position monitor turn-by-turn analysis for impedance characterization has been usually employed in large circumference machines, while synchrotron light sources have mainly used slow orbit based techniques...

  9. Pulsed-laser micropatterned quantum-dot array for white light source

    Science.gov (United States)

    Wang, Sheng-Wen; Lin, Huang-Yu; Lin, Chien-Chung; Kao, Tsung Sheng; Chen, Kuo-Ju; Han, Hau-Vei; Li, Jie-Ru; Lee, Po-Tsung; Chen, Huang-Ming; Hong, Ming-Hui; Kuo, Hao-Chung

    2016-03-01

    In this study, a novel photoluminescent quantum dots device with laser-processed microscale patterns has been demonstrated to be used as a white light emitting source. The pulsed laser ablation technique was employed to directly fabricate microscale square holes with nano-ripple structures onto the sapphire substrate of a flip-chip blue light-emitting diode, confining sprayed quantum dots into well-defined areas and eliminating the coffee ring effect. The electroluminescence characterizations showed that the white light emission from the developed photoluminescent quantum-dot light-emitting diode exhibits stable emission at different driving currents. With a flexibility of controlling the quantum dots proportions in the patterned square holes, our developed white-light emitting source not only can be employed in the display applications with color triangle enlarged by 47% compared with the NTSC standard, but also provide the great potential in future lighting industry with the correlated color temperature continuously changed in a wide range.

  10. Science and Technology of Future Light Sources: A White Paper

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, Uwe; Corlett, John; Dierker, Steve; Falcone, Roger; Galayda, John; Gibson, Murray; Hastings, Jerry; Hettel, Bob; Hill, John; Hussain, Zahid; Kao, Chi-Chang; Kirz, a= Janos; Long, Gabrielle; McCurdy, Bill; Raubenheimer, Tor; Sannibale, Fernando; Seeman, John; Shen, Z.-X.; Shenoy, Gopal; Schoenlein, Bob; Shen, Qun; /Argonne /Brookhaven /LBL, Berkeley /SLAC, SSRL

    2009-02-03

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects (Figure 1.1). The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter

  11. Validation of alternate light sources for detection of bruises in non-embalmed and embalmed cadavers.

    Science.gov (United States)

    Olds, Kelly; Byard, Roger W; Winskog, Calle; Langlois, Neil E I

    2017-03-01

    Bruising is frequently documented in cases of violence for use as forensic evidence. However, bruises can be overlooked if they are not visible to the naked eye. Alternate light sources such as ultraviolet, narrow band, and infrared have been used in an attempt to reveal the presence of bruising that is not otherwise apparent. However, there is a significant gap in knowledge surrounding this technique as it has not been validated against histology to confirm that bruising is genuinely being enhanced. A recent study evaluated the ability of alternate light sources to enhance visibility of bruises using a pigskin model. However, histological confirmation of bruising in humans using these light sources has not yet been performed. In this study, embalmed and non-embalmed human cadavers were used. Bodies were surveyed with alternate light sources, and enhanced regions that were unapparent under white light were photographed with the alternate light sources and sampled for histological assessment. Immunohistochemical staining for the red blood cell surface protein glycophorin was used determine if the enhanced area was a bruise (defined by the presence of extravasated erythrocytes). Photographs of areas confirmed to be bruises were analyzed using the program Fiji to measure enhancement, which was defined as an increase in the measured transverse diameter. In the non-embalmed and the embalmed cadavers violet alternate light produced the greatest enhancement of histologically confirmed bruises, followed by blue (both p light sources may not be specific. This suggests that the use of light sources to enhance the visibility of bruising should be undertaken with caution and further studies are required.

  12. My Precious! The Location and Diffusion of Scientific Research: Evidence from the Synchrotron Diamond Light Source

    OpenAIRE

    2013-01-01

    We analyze the impact of the establishment of a GBP 380 million basic scientific research facility in the UK on the geographical distribution of related research. We investigate whether the siting of the Diamond Light Source, a 3rd generation synchrotron light source, in Oxfordshire induced a clustering of related research in its geographic proximity. To account for the potentially endogenous location choice of the synchrotron, we exploit the availability of a 'runner-up' site near Manchester...

  13. Imaging spectroscopic analysis at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    MacDowell, A. A.; Warwick, T.; Anders, S.; Lamble, G.M.; Martin, M.C.; McKinney, W.R.; Padmore, H.A.

    1999-05-12

    One of the major advances at the high brightness third generation synchrotrons is the dramatic improvement of imaging capability. There is a large multi-disciplinary effort underway at the ALS to develop imaging X-ray, UV and Infra-red spectroscopic analysis on a spatial scale from. a few microns to 10nm. These developments make use of light that varies in energy from 6meV to 15KeV. Imaging and spectroscopy are finding applications in surface science, bulk materials analysis, semiconductor structures, particulate contaminants, magnetic thin films, biology and environmental science. This article is an overview and status report from the developers of some of these techniques at the ALS. The following table lists all the currently available microscopes at the. ALS. This article will describe some of the microscopes and some of the early applications.

  14. The synchrotron light source as a tool for microtechnology

    CERN Document Server

    Harvey, E C

    2002-01-01

    We are all familiar with lathes and milling machines for shaping parts in machine shops and factories. But what if the parts we need to make are significantly smaller than a millimetre, and featuring details even smaller? Semiconductor chip manufacturers have faced these problems and have learnt to use new ways to make devices. No longer are transistors made one at a time, but rather are 'printed' millions at a time, together with their interconnection wiring in a process called photolithography. Light from an excimer laser is directed through masks that incorporate the patterns required and photoexposes surfaces positioned behind the masks. This form of photolithography is today a standard process in semiconductor FAB plants and has several critical advantages in terms of cost, reproducibility, reliability and its ability to scale towards ever smaller and more complex systems

  15. Microlensing light curve of a source on the other side of a wormhole

    CERN Document Server

    Tsukamoto, Naoki

    2016-01-01

    The observation of microlensing is a good probe into the topological structure of dark gravitating celestial objects. In this paper, we study the microlensing light curves due to light rays emitted by a source on the other side of a traversable wormhole. The present method will apply for general spherically symmetric traversable wormholes. Based on the obtained light curves, we discuss a possibility to observationally distinguish traversable wormholes with nontrivial topology from usual positive masses and other exotic objects without nontrivial topology.

  16. Volume-scalable high-brightness three-dimensional visible light source

    Science.gov (United States)

    Subramania, Ganapathi; Fischer, Arthur J; Wang, George T; Li, Qiming

    2014-02-18

    A volume-scalable, high-brightness, electrically driven visible light source comprises a three-dimensional photonic crystal (3DPC) comprising one or more direct bandgap semiconductors. The improved light emission performance of the invention is achieved based on the enhancement of radiative emission of light emitters placed inside a 3DPC due to the strong modification of the photonic density-of-states engendered by the 3DPC.

  17. Performance of light sources and radiation sensors under low gravity realized by parabolic airplane flights

    Science.gov (United States)

    Hirai, Hiroaki; Kitaya, Yoshiaki; Hirai, Takehiro

    A fundamental study was conducted to establish an experimental system for space farming. Since to ensure optimal light for plant cultivation in space is of grave importance, this study examined the performance of light sources and radiation sensors under microgravity conditions created during the parabolic airplane flight. Three kinds of light sources, a halogen bulb, a fluorescent tube, and blue and red LEDs, and ten models of radiation sensors available in the market were used for the experiment. Surface temperature of the light sources, output signals from the radiation sensors, spectroscopic characteristics were measured at the gravity levels of 0.01, 1.0 and 1.8 G for 20 seconds each during parabolic airplane flights. As a result, the performance of the halogen lamp was affected the most by the gravity level among the three light sources. Under the microgravity conditions which do not raise heat convection, the temperature of the halogen lamp rose and the output of the radiation sensors increased. Spectral distributions of the halogen lamp indicated that peak wavelength appeared the highest at the level of 0.01G, which contributed to the increase in light intensity. In the case of red and blue LEDs, which are promising light sources in space farming, the temperature of both LED chips rose but irradiance from red LED increased and that from blue LED decreased under microgravity conditions due to the different thermal characteristics.

  18. Alternatives to Outdoor Daylight Illumination for Photodynamic Therapy--Use of Greenhouses and Artificial Light Sources

    DEFF Research Database (Denmark)

    Lerche, Catharina M; Heerfordt, Ida M; Heydenreich, Jakob

    2016-01-01

    -emitting diode (LED) lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse...

  19. A novel semiconductor-based, fully incoherent amplified spontaneous emission light source for ghost imaging

    Science.gov (United States)

    Hartmann, Sébastien; Elsäßer, Wolfgang

    2017-01-01

    Initially, ghost imaging (GI) was demonstrated with entangled light from parametric down conversion. Later, classical light sources were introduced with the development of thermal light GI concepts. State-of-the-art classical GI light sources rely either on complex combinations of coherent light with spatially randomizing optical elements or on incoherent lamps with monochromating optics, however suffering strong losses of efficiency and directionality. Here, a broad-area superluminescent diode is proposed as a new light source for classical ghost imaging. The coherence behavior of this spectrally broadband emitting opto-electronic light source is investigated in detail. An interferometric two-photon detection technique is exploited in order to resolve the ultra-short correlation timescales. We thereby quantify the coherence time, the photon statistics as well as the number of spatial modes unveiling a complete incoherent light behavior. With a one-dimensional proof-of-principle GI experiment, we introduce these compact emitters to the field which could be beneficial for high-speed GI systems as well as for long range GI sensing in future applications. PMID:28150737

  20. Second-order spatial correlation in the far-field: Comparing entangled and classical light sources

    Science.gov (United States)

    Zhang, Erfeng; Liu, Weitao; Lin, Huizu; Chen, Pingxing

    2016-02-01

    We consider second-order spatial correlation with entangled and classical light in the far-field. The quantum theory of second-order spatial correlation is analyzed, and the role of photon statistics and detection mode in the second-order spatial correlation are discussed. Meanwhile, the difference of second-order spatial correlation with entangled and classical light sources is deduced.

  1. A novel semiconductor-based, fully incoherent amplified spontaneous emission light source for ghost imaging

    Science.gov (United States)

    Hartmann, Sébastien; Elsäßer, Wolfgang

    2017-02-01

    Initially, ghost imaging (GI) was demonstrated with entangled light from parametric down conversion. Later, classical light sources were introduced with the development of thermal light GI concepts. State-of-the-art classical GI light sources rely either on complex combinations of coherent light with spatially randomizing optical elements or on incoherent lamps with monochromating optics, however suffering strong losses of efficiency and directionality. Here, a broad-area superluminescent diode is proposed as a new light source for classical ghost imaging. The coherence behavior of this spectrally broadband emitting opto-electronic light source is investigated in detail. An interferometric two-photon detection technique is exploited in order to resolve the ultra-short correlation timescales. We thereby quantify the coherence time, the photon statistics as well as the number of spatial modes unveiling a complete incoherent light behavior. With a one-dimensional proof-of-principle GI experiment, we introduce these compact emitters to the field which could be beneficial for high-speed GI systems as well as for long range GI sensing in future applications.

  2. Solution of multi-element LED light sources development automation problem

    Science.gov (United States)

    Chertov, Aleksandr N.; Gorbunova, Elena V.; Korotaev, Valery V.; Peretyagin, Vladimir S.

    2014-09-01

    The intensive development of LED technologies resulted in the creation of multicomponent light sources in the form of controlled illumination devices based on usage of mentioned LED technologies. These light sources are used in different areas of production (for example, in the food industry for sorting products or in the textile industry for quality control, etc.). The use of LED lighting products in the devices used in specialized lighting, became possible due to wide range of colors of light, LED structures (which determines the direction of radiation, the spatial distribution and intensity of the radiation, electrical, heat, power and other characteristics), and of course, the possibility of obtaining any shade in a wide dynamic range of brightness values. LED-based lighting devices are notable for the diversity of parameters and characteristics, such as color radiation, location and number of emitters, etc. Although LED technologies have several advantages, however, they require more attention if you need to ensure a certain character of illumination distribution and/or distribution of the color picture at a predetermined distance (for example, at flat surface, work zone, area of analysis or observation). This paper presents software designed for the development of the multicomponent LED light sources. The possibility of obtaining the desired color and energy distribution at the zone of analysis by specifying the spatial parameters of the created multicomponent light source and using of real power, spectral and color parameters and characteristics of the LEDs is shown as well.

  3. Monochromatic light-emitting diode (LED source in layers hens during the second production cycle

    Directory of Open Access Journals (Sweden)

    Rodrigo Borille

    2015-09-01

    Full Text Available ABSTRACTLight is an important environmental factor for birds, allowing not only their vision, but also influencing their physiological responses, such as behavioral and reproductive activity. The objective of this experiment was to evaluate the impact of different colors of monochromatic light (LED sources in laying hens production during the second laying cycle. The study was conducted in an experimental laying house during 70 days. A total of 300 laying hens Isa Brown® genetic strain, aged 95 weeks, in the second laying cycle were used in the study. The artificial light sources used were blue, yellow, green, red and white. The light regimen was continuous illumination of 17 h per day (12 h natural and 5 h artificial in a daily light regimen of 17L:5D (light: dark. The Latin Square design was adopted with five treatments (five colors divided into five periods, and five boxes, with six replicates of ten birds in each box. The production and egg quality were evaluated. The different colors of light source did not affect production parameters or egg quality (p > 0.05. The monochromatic light source may be considered as an alternative to artificial lighting in laying hens during the second production cycle.

  4. Development of tunable Fabry-Perot spectral camera and light source for medical applications

    Science.gov (United States)

    Kaarre, M.; Kivi, S.; Panouillot, P. E.; Saari, H.; Mäkynen, J.; Sorri, I.; Juuti, M.

    2013-05-01

    VTT has developed a fast, tunable Fabry-Perot (FP) filter component and applied it in making small, lightweight spectral cameras and light sources. One application field where this novel technology is now tested is medical field. A demonstrator has been made to test the applicability of FP based spectral filtering in the imaging of retina in visible light wavelength area.

  5. Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay.

    Science.gov (United States)

    Delferrière, O; Gobin, R; Harrault, F; Nyckees, S; Sauce, Y; Tuske, O

    2012-02-01

    One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

  6. Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclaya)

    Science.gov (United States)

    Delferrière, O.; Gobin, R.; Harrault, F.; Nyckees, S.; Sauce, Y.; Tuske, O.

    2012-02-01

    One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

  7. Antibacterial photodynamic therapy for dental caries: evaluation of the photosensitizers used and light source properties.

    Science.gov (United States)

    Nagata, Juliana Yuri; Hioka, Noboru; Kimura, Elza; Batistela, Vagner Roberto; Terada, Raquel Sano Suga; Graciano, Ariane Ximenes; Baesso, Mauro Luciano; Hayacibara, Mitsue Fujimaki

    2012-06-01

    Photodynamic therapy studies have shown promising results for inactivation of microorganisms related to dental caries. A large number of studies have used a variety of protocols, but few studies have analyzed photosensitizers and light source properties to obtain the best PDT dose response for dental caries. This study aims to discuss the photosensitizers and light source properties employed in PDT studies of dental caries. Three questions were formulated to discuss these aspects. The first involves the photosensitizer properties and their performance against Gram positive and Gram negative bacteria. The second discusses the use of light sources in accordance with the dye maximum absorbance to obtain optimal results. The third looks at the relevance of photosensitizer concentration, the possible formation of self-aggregates, and light source effectiveness. This review demonstrated that some groups of photosensitizers may be more effective against either Gram positive or negative bacteria, that the light source must be appropriate for dye maximum absorbance, and that some photosensitizers may have their absorbance modified with their concentration. For the best results of PDT against the main cariogenic bacteria (Streptococcus mutans), a variety of aspects should be taken into account, and among the analyzed photosensitizer, erythrosin seems to be the most appropriate since it acts against this Gram positive bacteria, has a hydrophilic tendency and even at low concentrations may have photodynamic effects. Considering erythrosin, the most appropriate light source should have a maximum emission intensity at a wavelength close to 530 nm, which may be achieved with low cost LEDs.

  8. Light inactivation of food-related pathogenic bacteria using a pulsed power source.

    Science.gov (United States)

    MacGregor, S J; Rowan, N J; Mcllvaney, L; Anderson, J G; Fouracre, R A; Farish, O

    1998-08-01

    The effects of high intensity light emissions, produced by a novel pulsed power energization technique (PPET), on the survival of bacterial populations of verocytotoxigenic Escherichia coli (serotype 0157:H7) and Listeria monocytogenes (serotype 4b) were investigated. Using this PPET approach, many megawatts (MW) of peak electrical power were dissipated in the light source in an extremely short energization time (about 1 microsecond). The light source was subjected to electric field levels greater than could be achieved under conventional continuous operation, which led to a greater production of the shorter bacteriocidal wavelengths of light. In the exposure experiments, pre-determined bacterial populations were spread onto the surface of Trypone Soya Yeast Extract Agar and were then treated to a series of light pulses (spectral range of 200-530 nm) with an exposure time ranging from 1 to 512 microseconds. While results showed that as few as 64 light pulses of 1 microsecond duration were required to reduce E. coli 0157:H7 populations by 99.9% and Listeria populations by 99%, the greater the number of light pulses the larger the reduction in cell numbers (P pulsed light emissions can significantly reduce populations of E. coli 0157:H7 and L. monocytogenes on exposed surfaces with exposure times which are 4-6 orders of magnitude lower than those required using continuous u.v. light sources.

  9. EDITORIAL: Extreme Ultraviolet Light Sources for Semiconductor Manufacturing

    Science.gov (United States)

    Attwood, David

    2004-12-01

    The International Technology Roadmap for Semiconductors (ITRS) [1] provides industry expectations for high volume computer chip fabrication a decade into the future. It provides expectations to anticipated performance and requisite specifications. While the roadmap provides a collective projection of what international industry expects to produce, it does not specify the technology that will be employed. Indeed, there are generally several competing technologies for each two or three year step forward—known as `nodes'. Recent successful technologies have been based on KrF (248 nm), and now ArF (193 nm) lasers, combined with ultraviolet transmissive refractive optics, in what are known as step and scan exposure tools. Less fortunate technologies in the recent past have included soft x-ray proximity printing and, it appears, 157 nm wavelength F2 lasers. In combination with higher numerical aperture liquid emersion optics, 193 nm is expected to be used for the manufacture of leading edge chip performance for the coming five years. Beyond that, starting in about 2009, the technology to be employed is less clear. The leading candidate for the 2009 node is extreme ultraviolet (EUV) lithography, however this requires that several remaining challenges, including sufficient EUV source power, be overcome in a timely manner. This technology is based on multilayer coated reflective optics [2] and an EUV emitting plasma. Following Moore's Law [3] it is expected, for example, that at the 2009 `32 nm node' (printable patterns of 32 nm half-pitch), isolated lines with 18 nm width will be formed in resist (using threshold effects), and that these will be further narrowed to 13 nm in transfer to metalized electronic gates. These narrow features are expected to provide computer chips of 19 GHz clock frequency, with of the order of 1.5 billion transistors per chip [1]. This issue of Journal of Physics D: Applied Physics contains a cluster of eight papers addressing the critical

  10. High Power Light Gas Helicon Plasma Source For VASMIR

    Science.gov (United States)

    Squire, J. P.; Chang-Diaz, F. R.; Glover, T. W.; Jacobson, V. T.; McCaskill, G. E.; Winter, D. S.; Baity, F. W.; Carter, M. D.; Goulding, R. H.

    2004-01-01

    The VASIMR space propulsion development effort relies on a high power (greater than 10kW) helicon source to produce a dense flowing plasma (H, D and He) target for ion cyclotron resonance (ICR) acceleration of the ions. Subsequent expansion in an expanding magnetic field (magnetic nozzle) converts ion lunetic energy to directed momentum. This plasma source must have critical features to enable an effective propulsion device. First, it must ionize most of the input neutral flux of gas, thus producing a plasma stream with a high degree of ionization for application of ICR power. This avoids propellant waste and potential power losses due to charge exchange. Next, the plasma stream must flow into a region of high magnetic field (approximately 0.5 T) for efficient ICR acceleration. Third, the ratio of input power to plasma flux must be low, providing an energy per ion-electron pair approaching 100 eV. Lastly, the source must be robust and capable of very long life-times (years). In our helicon experiment (VX-10) we have measured a ratio of input gas to plasma flux near 100%. The plasma flows from the helicon region (B approximately 0.1 T) into a region with a peak magnetic field of 0.8 T. The energy input per ion-electron pair has been measured at 300 plus or minus 100 eV. Recent results at Oak Ridge National Laboratory (ORNL) show an enhanced efficiency mode of operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 3.5 kW of input power. An upgrade to a power level of 10 kW is underway. Much of our recent work has been with a Boswell double-saddle antenna design. We are also converting the antenna design to a helical type. With these modifications, we anticipate an improvement in the ionization efficiency. This paper presents the results from scaling the helicon in the VX-10 device from 3.5 to 10 kW. We also compare the operation with a double-saddle to a helical antenna design. Finally, we

  11. High Power Light Gas Helicon Plasma Source For VASMIR

    Science.gov (United States)

    Squire, J. P.; Chang-Diaz, F. R.; Glover, T. W.; Jacobson, V. T.; McCaskill, G. E.; Winter, D. S.; Baity, F. W.; Carter, M. D.; Goulding, R. H.

    2004-01-01

    The VASIMR space propulsion development effort relies on a high power (greater than 10kW) helicon source to produce a dense flowing plasma (H, D and He) target for ion cyclotron resonance (ICR) acceleration of the ions. Subsequent expansion in an expanding magnetic field (magnetic nozzle) converts ion lunetic energy to directed momentum. This plasma source must have critical features to enable an effective propulsion device. First, it must ionize most of the input neutral flux of gas, thus producing a plasma stream with a high degree of ionization for application of ICR power. This avoids propellant waste and potential power losses due to charge exchange. Next, the plasma stream must flow into a region of high magnetic field (approximately 0.5 T) for efficient ICR acceleration. Third, the ratio of input power to plasma flux must be low, providing an energy per ion-electron pair approaching 100 eV. Lastly, the source must be robust and capable of very long life-times (years). In our helicon experiment (VX-10) we have measured a ratio of input gas to plasma flux near 100%. The plasma flows from the helicon region (B approximately 0.1 T) into a region with a peak magnetic field of 0.8 T. The energy input per ion-electron pair has been measured at 300 plus or minus 100 eV. Recent results at Oak Ridge National Laboratory (ORNL) show an enhanced efficiency mode of operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 3.5 kW of input power. An upgrade to a power level of 10 kW is underway. Much of our recent work has been with a Boswell double-saddle antenna design. We are also converting the antenna design to a helical type. With these modifications, we anticipate an improvement in the ionization efficiency. This paper presents the results from scaling the helicon in the VX-10 device from 3.5 to 10 kW. We also compare the operation with a double-saddle to a helical antenna design. Finally, we

  12. 49 CFR Appendix B to Part 564 - Information To Be Submitted for Long Life Replaceable Light Sources of Limited Definition

    Science.gov (United States)

    2010-10-01

    ... TRANSPORTATION REPLACEABLE LIGHT SOURCE INFORMATION (Eff. until 12-01-12) Pt. 564, App. B Appendix B to Part 564—Information To Be Submitted for Long Life Replaceable Light Sources of Limited Definition I. Filament or... plane. D. For a light source using excited gas mixtures as a filament, necessary fiducial information...

  13. Long lifetime, low intensity light source for use in nighttime viewing of equipment maps and other writings

    Science.gov (United States)

    Frank, Alan M.; Edwards, William R.

    1983-01-01

    A long-lifetime light source with sufficiently low intensity to be used for reading a map or other writing at nighttime, while not obscuring the user's normal night vision. This light source includes a diode electrically connected in series with a small power source and a lens properly positioned to focus at least a portion of the light produced by the diode.

  14. Gallium Nitride Nanowires and Heterostructures: Toward Color-Tunable and White-Light Sources.

    Science.gov (United States)

    Kuykendall, Tevye R; Schwartzberg, Adam M; Aloni, Shaul

    2015-10-14

    Gallium-nitride-based light-emitting diodes have enabled the commercialization of efficient solid-state lighting devices. Nonplanar nanomaterial architectures, such as nanowires and nanowire-based heterostructures, have the potential to significantly improve the performance of light-emitting devices through defect reduction, strain relaxation, and increased junction area. In addition, relaxation of internal strain caused by indium incorporation will facilitate pushing the emission wavelength into the red. This could eliminate inefficient phosphor conversion and enable color-tunable emission or white-light emission by combining blue, green, and red sources. Utilizing the waveguiding modes of the individual nanowires will further enhance light emission, and the properties of photonic structures formed by nanowire arrays can be implemented to improve light extraction. Recent advances in synthetic methods leading to better control over GaN and InGaN nanowire synthesis are described along with new concept devices leading to efficient white-light emission.

  15. Organic light sources look forward to optimize the photosynthesis process

    Science.gov (United States)

    Fattori, Valeria; Williams, J. A. Gareth; Murphy, Lisa; Cocchi, Massimo; Kalinowski, Jan

    2008-12-01

    We introduce a series of organic LEDs that exploit the monomer and excimer emissions from single phosphor dopant emitters. These organic LEDs were found to be effective in the simultaneous creation of blue and red emission bands essential for plant growth. By varying the concentration of novel phosphorescent dopants selected from a series of newly synthesized platinum complexes [Pt L22-25Cl], we have manufactured the blue-biased LEDs [with the Commission Internationale de L’Eclairage (CIE) coordinates ( x, y) (0.27, 0.37)] and the red-biased LEDs [CIE coordinates (0.53, 0.38)], at a high luminance of ≈500 cd/m 2 and with external electroluminescence (EL) quantum efficiency of 15-18% photon/electron (→ power efficiency 8-12 lm/W). The EL spectrum most suitable for the action spectrum of photosynthesis yield was that of a device incorporating 20 wt.% content of [Pt L23Cl]. This LED yielded photosynthetic photon flux (PPF) approaching 10 μmol s -1 W -1 of the electrical power, a value which significantly exceeds that for the professional lamps used commonly for horticultural lighting.

  16. Compact excimer laser light source for optical (mask) inspection systems

    Science.gov (United States)

    Pflanz, Tobias; Huber, Heinz

    2001-04-01

    The discharge pumped excimer laser is a gas laser providing ultra violet radiation with well defined spectral, temporal and spatial properties. The fast development of excimer lasers in recent years has succeeded in designing very compact, turn-key systems delivering up to 10 W of radiation at 248 nm (5 W at 193 nm and 1 W at 157 nm) with repetition rates up to 1000 Hz. Experimental data on important beam properties of excimer lasers in the field of mask inspection are being presented and discussed. Relevant parameters are spectral bandwidth, energetic pulse-to-pulse stability, pulse duration, beam pointing stability, beam direction stability, beam dimension, beam profile and coherence. We will compare the excimer laser with lamp sources and continuous wave lasers in the framework of these parameters. The discussion will show future opportunities of compact excimer lasers in optical inspection as well as in mask writing systems, improving resolution and throughput.

  17. Report of the Basic Energy Sciences Workshop on Compact Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Barletta, William A. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Borland, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2010-05-11

    This report is based on a BES Workshop on Compact Light Sources, held May 11-12, 2010, to evaluated the advantages and disadvantages of compact light source approaches and compared their performance to the third generation storage rings and free-electron lasers. The workshop examined the state of the technology for compact light sources and their expected progress. The workshop evaluated the cost efficiency, user access, availability, and reliability of such sources. Working groups evaluated the advantages and disadvantages of Compact Light Source (CLS) approaches, and compared their performance to the third-generation storage rings and free-electron lasers (FELs). The primary aspects of comparison were 1) cost effectiveness, 2) technical availability v. time frame, and 3) machine reliability and availability for user access. Five categories of potential sources were analyzed: 1) inverse Compton scattering (ICS) sources, 2) mini storage rings, 3) plasma sources, 4) sources using plasma-based accelerators, and 5) laser high harmonic generation (HHG) sources. Compact light sources are not a substitute for large synchrotron and FEL light sources that typically also incorporate extensive user support facilities. Rather they offer attractive, complementary capabilities at a small fraction of the cost and size of large national user facilities. In the far term they may offer the potential for a new paradigm of future national user facility. In the course of the workshop, we identified overarching R&D topics over the next five years that would enhance the performance potential of both compact and large-scale sources: Development of infrared (IR) laser systems delivering kW-class average power with femtosecond pulses at kHz repetition rates. These have application to ICS sources, plasma sources, and HHG sources. Development of laser storage cavities for storage of 10-mJ picosecond and femtosecond pulses focused to micron beam sizes. Development of high-brightness, high

  18. A compact 3.5-dB squeezed light source with atomic ensembles

    CERN Document Server

    Bao, Guzhi; Chen, Bing; Guo, Jinxian; Shen, Heng; Chen, Liqing; Zhang, Weiping

    2015-01-01

    We reported a compact squeezed light source consisting of an diode laser near resonant on 87Rb optical D1 transition and an warm Rubidium vapor cell. The -4dB vacuum squeezing at 795 nm via nonlinear magneto-optical rotation was observed when applying the magnetic field orthogonal to the propagation direction of the light beam. This compact squeezed light source can be potentially utilized in the quantum information protocols such as quantum repeater and memory, and quantum metrology such as atomic magnetometer.

  19. Comparison of stray light in spectrometer systems using a low cost monochromatic light source

    DEFF Research Database (Denmark)

    Thorseth, Anders; Lindén, Johannes; Dam-Hansen, Carsten

    2014-01-01

    We present an experimental setup that is under development for automated stray light characterization of spectrometers. The setup uses a tuneable monochromator which enables this characterization on relatively cost low equipment. We present the measured line spread functions for two spectrometers...

  20. Light source design using Kagome-lattice hollow core photonic crystal fibers

    Science.gov (United States)

    Hossain, Md. Anwar; Namihira, Yoshinori

    2014-09-01

    Supercontinuum (SC) light source is designed using high pressure Xe-filled hollow core Kagome-lattice photonic crystal fiber. Using finite element method with perfectly matched layer, SC spectra in normal chromatic dispersion region have been generated using picosecond optical pulses from relatively less expensive laser sources.

  1. Surface hardness comparison of resins polymerized by argon, xenon, and conventional light sources

    Science.gov (United States)

    Blankenau, Richard J.; Pace, Scott; Powell, G. L.; Wilwerding, Terry

    1996-04-01

    A great deal of discussion has taken place regarding how to properly polymerize light activated resins. Claims are made that effective testing can be made by using surface hardness tests on samples with various dental instruments. Although these tests would probably identify a material that had been very poorly polymerized it would not identify materials that were properly polymerized. The lack of consistent, reproducible forces and evaluation of the results make these test practically worthless. Surface hardness which is important clinically has value when combined with evaluation of the surface immediately adjacent to the light source and the surface adjacent to the tooth. Also immediate and 24 hour testing to allow for continued polymerization is helpful in determining how to achieve best results for our patients. A variety of new light sources have been introduced to dentistry with claims of faster and better polymerizations. The visible light units are also undergoing improvements to include built in meters to monitor light output. The purpose of this study was to evaluate the top and bottom surface hardness of a composite resin using the following light sources: argon, xenon, and two visible light sources.

  2. Potential diagnostics for the next-generation light sources

    CERN Document Server

    Lumpkin, Alex H

    1999-01-01

    There is continued interest in developing a diffraction-limited soft or hard X-ray source. Candidate paths include the storage-ring-based free-electron laser (FEL) and the linac-based self-amplified spontaneous emission (SASE) FEL for the two regimes, respectively. As previously discussed, target beam parameters are sigma sub x sub , sub y approx 10 mu m, sigma sub x sub ' sub , sub y sub ' =1 mu rad, and sigma sub t approx 1 ps (0.1 ps for the linac case). We report the use of few- to sub-angstrom radiation emitted by a 7-GeV beam transitting a 198-period diagnostics undulator and a bending magnet to characterize the particle beam. A particle beam divergence as low as sigma sub y sub ' =3.3 mu rad was measured using an X-ray monochromator. Additionally, a particle beam size of sigma sub y <45 mu m and a bunch length of sigma sub t =28 ps with 4-ps resolution were measured using an X-ray pinhole camera with a unique synchroscan and dual-sweep X-ray streak camera as the detector. The adjustable pinhole aper...

  3. Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source.

    Science.gov (United States)

    Ko, Tony; Adler, Desmond; Fujimoto, James; Mamedov, Dmitry; Prokhorov, Viatcheslav; Shidlovski, Vladimir; Yakubovich, Sergei

    2004-05-17

    Ultrahigh resolution optical coherence tomography imaging is performed with a compact broadband superluminescent diode light source. The source consists of two multiplexed broadband superluminescent diodes and has a power output of 4 mW with a spectral bandwidth of 155 nm, centered at a wavelength of 890 nm. In vivo imaging was performed with approximately 2.3 microm axial resolution in scattering tissue and approximately 3.2 microm axial resolution in the retina. These results demonstrate that it is possible to perform in vivo ultrahigh resolution optical coherence tomography imaging using a superluminescent diode light source that is inexpensive, compact, and easy to operate.

  4. Synchrotron light source data book: Version 4, Revision 05/96

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, J.B.

    1996-05-01

    This book is as its name implies a collection of data on existing and planned synchrotron light sources. The intention was to provide a compendium of tools for the design of electron storage rings as synchrotron radiation sources. The slant is toward the accelerator physicist as other booklets such as the X-Ray Data Booklet address the use of synchrotron radiation. It is hoped that the booklet serves as a pocket sized reference to facilitate back of the envelope type calculations. It contains some useful formulae in practical units and a brief description of many of the existing and planned light source lattices.

  5. MEDICAL ENTITIES –FINANCING TYPES AND SOURCES IN LIGHT OF THE ACT ON MEDICAL ACTIVITY

    Directory of Open Access Journals (Sweden)

    Małgorzata Paszkowska

    2014-04-01

    Full Text Available Defining legally permitted financing sources is fundamental for each medical entity. The act on medical activity of 15th April 2011introduced many changes for medical service suppliers also as concerns the permitted financing sources. This paper aims to present the types of medical entities and their financing sources in the light of the new regulations, i.e. the act on medical activity.

  6. Frequency-swept Light Sources for Optical Coherence Tomography in the 1060nm range

    DEFF Research Database (Denmark)

    Marschall, Sebastian

    by cataract. For the 1060nm band, rapidly tunable lasers|so-called swept sources|are available which enable ultra-high speed acquisition of large three-dimensional datasets. However, these light sources require further improvements: higher output power for sufficient signal quality and wider tuning bandwidth...... of retinal imaging. Our simulation reveals a general relationship between the light source bandwidth and the optimal center wavelength, which is supported by our experimental results. This relationship constitutes an important design criterion for future development of high-speed broadband swept sources....... instrument in the biomedical eld, especially in ophthalmology, where it is used for diagnosing retinal diseases. Using light at 1060nm permits deep penetration into the retina and into the layers beneath, the choroid and the sclera. This wavelength range is also benecial for imaging in eyes affected...

  7. Photoacoustic thermal flowmetry with a single light source.

    Science.gov (United States)

    Liu, Wei; Lan, Bangxin; Hu, Leo; Chen, Ruimin; Zhou, Qifa; Yao, Junjie

    2017-09-01

    We report a photoacoustic thermal flowmetry based on optical-resolution photoacoustic microscopy (OR-PAM) using a single laser source for both thermal tagging and photoacoustic excitation. When an optically absorbing medium is flowing across the optical focal zone of OR-PAM, a small volume of the medium within the optical focus is repeatedly illuminated and heated by a train of laser pulses with a high repetition rate. The average temperature of the heated volume at each laser pulse is indicated by the photoacoustic signal excited by the same laser pulse due to the well-established linear relationship between the Grueneisen coefficient and the local temperature. The thermal dynamics of the heated medium volume, which are closely related to the flow speed, can therefore be measured from the time course of the detected photoacoustic signals. Here, we have developed a lumped mathematical model to describe the time course of the photoacoustic signals as a function of the medium's flow speed. We conclude that the rising time constant of the photoacoustic signals is linearly dependent on the flow speed. Thus, the flow speed can be quantified by fitting the measured photoacoustic signals using the derived mathematical model. We first performed proof-of-concept experiments using defibrinated bovine blood flowing in a plastic tube. The experiment results have demonstrated that the proposed method has high accuracy (∼±6%) and a wide range of measurable flow speeds. We further validated the method by measuring the blood flow speeds of the microvasculature in a mouse ear in vivo. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  8. Source attribution of light-absorbing impurities in seasonal snow across northern China

    Directory of Open Access Journals (Sweden)

    R. Zhang

    2013-01-01

    Full Text Available Seasonal snow samples obtained at 46 sites in 6 provinces of China in January and February 2010 were analyzed for a suite of chemical species and these data are combined with previously determined concentrations of light-absorbing impurities (LAI, including all particles that absorb light in the 650–700 nm wavelength interval. The LAI, together with 14 other analytes, are used as input to a positive matrix factorization (PMF receptor model to explore the sources of the LAI in the snow. The PMF analysis for the LAI sources is augmented with backward trajectory cluster analysis and the geographic locations of major source areas for the three source types. The two analyses are consistent and indicate that three factors/sources were responsible for the measured snow light absorption: a soil dust source, an industrial pollution source, and a biomass and biofuels burning source. Soil dust was the main source of the LAI, accounting for ~ 53% of the LAI on average.

  9. Source attribution of insoluble light-absorbing particles in seasonal snow across northern China

    Directory of Open Access Journals (Sweden)

    R. Zhang

    2013-06-01

    Full Text Available Seasonal snow samples obtained at 46 sites in 6 provinces of China in January and February 2010 were analyzed for a suite of chemical species and these data are combined with previously determined concentrations of insoluble light-absorbing particles (ILAP, including all particles that absorb light in the 650–700 nm wavelength interval. The ILAP, together with 14 other analytes, are used as input to a positive matrix factorization (PMF receptor model to explore the sources of ILAP in the snow. The PMF analysis for ILAP sources is augmented with backward trajectory cluster analysis and the geographic locations of major source areas for the three source types. The two analyses are consistent and indicate that three factors/sources were responsible for the measured light absorption of snow: a soil dust source, an industrial pollution source, and a biomass and / or biofuel burning source. Soil dust was the main source of the ILAP, accounting for ~53% of ILAP on average.

  10. Light Drag Effect of Vacuum Tube Versus Light Propagation in Stationary Vacuum Tube with Moving Source and Receiver

    CERN Document Server

    Wang, Ruyong; He, Le; Zhang, Wenyan; Zhang, Liang

    2016-01-01

    We presented a new way to examine the principle of relativity of Special Relativity. According to the principle of relativity, the light dragging by moving media and the light propagation in stationary media with moving source and receiver should be two totally equivalent phenomena. We select a vacuum tube with two glass rods at two ends as the optical media. The length of the middle vacuum cell is L and the thicknesses of the glass rods with refractive index n are D1 and D2. The light drag effect of the moving vacuum tube with speed v is a first-order effect, delta t = 2(n-1)(D1+D2)v/c^2, which is independent of L because vacuum does not perform a drag effect. Predicted by the principle of relativity, the change of the light propagation time interval with stationary vacuum tube and moving source and receiver must be the same, i.e., delta tao = delta t = 2(n-1)(D1+D2)v/c^2. However all analyses have shown that the change of the propagation time interval delta tao is caused by the motion of the receiver during...

  11. Measuring light spectrum as a main indicator of artificial sources quality

    Institute of Scientific and Technical Information of China (English)

    Piotr Dbrowski; Magdalena Danuta Cetner; IzabelaAnna Samborska; Mohamed Hazem Kalaji

    2015-01-01

    Objective: To compare different artificial light sources in different places where plant breeding is conduced. Methods: Measurements were conducted outdoor, in room, in greenhouse, under four panels with light emitting diodes, in phytotron, in dark room with various light sources and inside Sanyo versatile environmental chamber. The measurements were made by using SpectraPen SP100 (PSI, Czech Republic) device. Results: Our result showed that spectrum measured outdoor during sunny day had only one peak at the wavelength of 485 nm (ca. 60000 relative units). On cloudy day, the trend of light spectrum curve was similar, but with lower values. At room conditions, the curve was more flat than outdoor. Under greenhouse conditions, the curve was similar to that measured outdoor. A few additional peaks on the curve appeared by adding high pressure sodium lamp. There were changes of curve under LED panels. Conclusions: It must be underlined that the most similar spectrum curve to daylight light has incandescent bulb and this light source should be preferred as support of daylight in greenhouses and as main source in phytotrons. Using high pressure sodium lamp in greenhouses as support of daylight cause increase in the red/far-red ratio and occurrence of a new peak on spectrum curve. The new possibilities are creating by LED panels with red and blue diodes.

  12. Environmental remediation and superhydrophilicity of ultrafine antibacterial tungsten oxide-based nanofibers under visible light source

    Energy Technology Data Exchange (ETDEWEB)

    Srisitthiratkul, Chutima; Yaipimai, Wittaya [Nano Functional Textile Laboratory, National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), 111 Thailand Science Park, Phahonyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 (Thailand); Intasanta, Varol, E-mail: varol@nanotec.or.th [Nano Functional Textile Laboratory, National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), 111 Thailand Science Park, Phahonyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 (Thailand)

    2012-10-15

    Graphical abstract: Nanosilver-decorated WO{sub 3} photocatalytic nanofibers are antibacterial and superhydrophilic under a visible light source. Highlights: Black-Right-Pointing-Pointer Deposition of nanosilver onto electrospun WO{sub 3} nanofibers' surface was done exploiting visible or UV light driven photoreduction of silver ion. Black-Right-Pointing-Pointer Nanofibers showed antibacterial characteristics. Black-Right-Pointing-Pointer Nanofibers degraded a model toxin effectively. Black-Right-Pointing-Pointer Nanofibers showed superhydrophilicity under a visible light source. - Abstract: Fabrication of nanosilver-decorated WO{sub 3} nanofibers was successfully performed. First, deposition of nanosilver onto electrospun WO{sub 3} nanofibers' surface was done via photoreduction of silver ion under visible or UV light. The resulting hybrid nanofibers not only revealed antibacterial characteristics but also maintained their photocatalytic performance towards methylene blue decomposition. Unexpectedly, the nanofibrous layers prepared from these nanofibers showed superhydrophilicity under a visible light source. The nanofibers might be advantageous in environmental and hygienic nanofiltration under natural light sources, where the self-cleaning characteristics could be valuable in maintenance processes.

  13. Multi-wavelength mid-IR light source for gas sensing

    Science.gov (United States)

    Karioja, Pentti; Alajoki, Teemu; Cherchi, Matteo; Ollila, Jyrki; Harjanne, Mikko; Heinilehto, Noora; Suomalainen, Soile; Viheriälä, Jukka; Zia, Nouman; Guina, Mircea; Buczyński, Ryszard; Kasztelanic, Rafał; Kujawa, Ireneusz; Salo, Tomi; Virtanen, Sami; Kluczyński, Paweł; Sagberg, Hâkon; Ratajczyk, Marcin; Kalinowski, Przemyslaw

    2017-02-01

    Cost effective multi-wavelength light sources are key enablers for wide-scale penetration of gas sensors at Mid-IR wavelength range. Utilizing novel Mid-IR Si-based photonic integrated circuits (PICs) filter and wide-band Mid-IR Super Luminescent Light Emitting Diodes (SLEDs), we show the concept of a light source that covers 2.5…3.5 μm wavelength range with a resolution of price can be lowered in high volumes by utilizing tailored molded IR lens technology and automated packaging and assembling technologies. The status of the development of the key components of the light source are reported. The PIC is based on the use of micron-scale SOI technology, SLED is based on AlGaInAsSb materials and the lenses are tailored heavy metal oxide glasses fabricated by the use of hot-embossing. The packaging concept utilizing automated assembly tools is depicted. In safety and security applications, the Mid-IR wavelength range covered by the novel light source allows for detecting several harmful gas components with a single sensor. At the moment, affordable sources are not available. The market impact is expected to be disruptive, since the devices currently in the market are either complicated, expensive and heavy instruments, or the applied measurement principles are inadequate in terms of stability and selectivity.

  14. EFFECT OF ENERGY EFFICIENT LIGHT SOURCES ON READABILITY OF STUDENTS – AN EXPERIMENTAL APPROACH

    Directory of Open Access Journals (Sweden)

    SATHYA P.

    2016-01-01

    Full Text Available The objective of this paper is to investigate the effect of light sources on readability of students using psychophysical methods. Light sources such as Compact Fluorescent Lamp (CFL and Light Emitting Diode lamp (LED of same power rating were used in this research work because of their high lighting efficiency and uniformity of illuminance compared to that of Incandescent lamp (IL and florescent lamp (FL. A group of prospective students having normal vision, and abnormal vision like myopia, hypermetropia and astigmatism were involved in the test process. Three types of test like Snellen visual acuity, Color contrast test and Readability test were conducted on student participants under different lighting conditions. Test results showed the visibility and color contrast sensitivity of the students were high in the LED illumination. The quantitative measure of readability under different circumstances showed that the lightness difference on text under different color combination and font size, affected their readability. The computed average results confirmed that the luminance and color contrast were improved in LED illumination and also proved a high readability measure in the experimentation. Both the results of psychophysical test were proven that LED lighting was the best lighting system suitable for color distinction and readability.

  15. Second-order spatial correlation in the far-field: Comparing entangled and classical light sources

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Erfeng, E-mail: efzhang@163.com; Liu, Weitao; Lin, Huizu; Chen, Pingxing

    2016-02-15

    Highlights: • Second-order spatial correlation with entangled and classical light in the far-field is investigated. • The role of photon statistics and detection mode in the second-order spatial correlation are discussed. • The difference of second-order spatial correlation with entangled and classical light sources is deduced. - Abstract: We consider second-order spatial correlation with entangled and classical light in the far-field. The quantum theory of second-order spatial correlation is analyzed, and the role of photon statistics and detection mode in the second-order spatial correlation are discussed. Meanwhile, the difference of second-order spatial correlation with entangled and classical light sources is deduced.

  16. High-Power, Computer-Controlled, Light-Emitting Diode–Based Light Sources for Fluorescence Imaging and Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Sylvain Gioux

    2009-05-01

    Full Text Available Optical imaging requires appropriate light sources. For image-guided surgery, in particular fluorescence-guided surgery, a high fluence rate, a long working distance, computer control, and precise control of wavelength are required. In this article, we describe the development of light-emitting diode (LED-based light sources that meet these criteria. These light sources are enabled by a compact LED module that includes an integrated linear driver, heat dissipation technology, and real-time temperature monitoring. Measuring only 27 mm wide by 29 mm high and weighing only 14.7 g, each module provides up to 6,500 lx of white (400–650 nm light and up to 157 mW of filtered fluorescence excitation light while maintaining an operating temperature ≤ 50°C. We also describe software that can be used to design multimodule light housings and an embedded processor that permits computer control and temperature monitoring. With these tools, we constructed a 76-module, sterilizable, three-wavelength surgical light source capable of providing up to 40,000 lx of white light, 4.0 mW/cm2 of 670 nm near-infrared (NIR fluorescence excitation light, and 14.0 mW/cm2 of 760 nm NIR fluorescence excitation light over a 15 cm diameter field of view. Using this light source, we demonstrated NIR fluorescence–guided surgery in a large-animal model.

  17. LIGHT SOURCE: Spot size diagnostics for flash radiographic X-ray sources at LAPA

    Science.gov (United States)

    Li, Cheng-Gang; Li, Qin; Shi, Jin-Shui; Deng, Jian-Jun

    2009-06-01

    Spot size is one of the parameters to characterize the performance of a radiographic X-ray source. It determines the degree of blurring due to magnification directly. In recent years, a variety of measurement methods have been used to diagnose X-ray spot size at Laboratory of Accelerator Physics and Application (LAPA). Computer simulations and experiments showed that using a rolled-edge to measure the spot size are more accurate, and the intensity distribution of X-ray source was obtained by a device with a square aperture. Experimental and simulation results on a flash X-ray source at our laboratory are presented and discussed in this paper. In addition, a new method for time resolved diagnostics of X-ray spot size is introduced too.

  18. Recent Beam Measurements and New Instrumentation at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, F.; Baptiste, K.; Barry, W.; Chin, M.; /LBL, Berkeley; Filippetto, D.; /Frascati; Jaegerhofer, L.; /Vienna, Tech. U.; Julian, J.; Kwiatkowski, S.; Low, R.; Plate, D.; Portmann, G.; Robin, D.; Scarvie, T.; /LBL, Berkeley; Stupakov, G.; /SLAC; Weber, J.; Zolotorev, M.; /LBL, Berkeley

    2012-04-11

    The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.

  19. Advances in broad bandwidth light sources for ultrahigh resolution optical coherence tomography.

    Science.gov (United States)

    Unterhuber, A; Povazay, B; Bizheva, K; Hermann, B; Sattmann, H; Stingl, A; Le, T; Seefeld, M; Menzel, R; Preusser, M; Budka, H; Schubert, Ch; Reitsamer, H; Ahnelt, P K; Morgan, J E; Cowey, A; Drexler, W

    2004-04-07

    Novel ultra-broad bandwidth light sources enabling unprecedented sub-2 microm axial resolution over the 400 nm-1700 nm wavelength range have been developed and evaluated with respect to their feasibility for clinical ultrahigh resolution optical coherence tomography (UHR OCT) applications. The state-of-the-art light sources described here include a compact Kerr lens mode locked Ti:sapphire laser (lambdaC = 785 nm, delta lambda = 260 nm, P(out) = 50 mW) and different nonlinear fibre-based light sources with spectral bandwidths (at full width at half maximum) up to 350 nm at lambdaC = 1130 nm and 470 nm at lambdaC = 1375 nm. In vitro UHR OCT imaging is demonstrated at multiple wavelengths in human cancer cells, animal ganglion cells as well as in neuropathologic and ophthalmic biopsies in order to compare and optimize UHR OCT image contrast, resolution and penetration depth.

  20. Enhancement for Φ-OTDR performance by using narrow linewidth light source and signal processing

    Science.gov (United States)

    Zhang, Meng; Wang, Song; Zheng, Yuanwei; Yang, Yao; Sa, Xingjie; Zhang, Li

    2016-03-01

    In order to enhance the signal-to-noise-ratio of a distributed acoustic sensing system based on phase-sensitive optical time-domain reflectometry (Φ-OTDR), we have proposed a combination of segmented unwrapping algorithm, averaging estimation of phase difference, and infinite impulse response (IIR) filtering method. The enhancement of signal quality is numerically demonstrated. Moreover, we have studied the influence resulted from the light source noise on the Φ-OTDR performance. The result has shown that when the linewidth of light source used in the Φ-OTDR system is narrower, the performance of the system is better. In a word, such a Φ-OTDR system could obtain higher quality demodulated signals when the narrower linewidth light source is chosen and the method of averaging estimation phase difference is used.

  1. Beam-based model of broad-band impedance of the Diamond Light Source

    Science.gov (United States)

    Smaluk, Victor; Martin, Ian; Fielder, Richard; Bartolini, Riccardo

    2015-06-01

    In an electron storage ring, the interaction between a single-bunch beam and a vacuum chamber impedance affects the beam parameters, which can be measured rather precisely. So we can develop beam-based numerical models of longitudinal and transverse impedances. At the Diamond Light Source (DLS) to get the model parameters, a set of measured data has been used including current-dependent shift of betatron tunes and synchronous phase, chromatic damping rates, and bunch lengthening. A matlab code for multiparticle tracking has been developed. The tracking results and analytical estimations are quite consistent with the measured data. Since Diamond has the shortest natural bunch length among all light sources in standard operation, the studies of collective effects with short bunches are relevant to many facilities including next generation of light sources.

  2. New horizons for Supercontinuum light sources: from UV to mid-IR

    DEFF Research Database (Denmark)

    Thomsen, Carsten L.; Nielsen, Frederik Donbæk; Johansen, Jeppe;

    2013-01-01

    Commercially available supercontinuum sources continue to experience a strong growth in a wide range of industrial and scientific applications. In addition, there is a significant research effort focused on extending the wavelength coverage both towards UV and Mid-IR. Broadband sources covering...... these wavelength regions have received significant attention from potential users, as there is a wide array of applications for which there are few suitable alternative light sources – if any. Our developments in the field of Mid-IR supercontinuum sources have been based on radical approaches; such as soft glasses...

  3. Quantum Rod Emission Coupled to Plasmonic Lattice Resonances: A Collective Directional Source of Polarized Light

    CERN Document Server

    Rodriguez, S R K; Verschuuren, M A; Gomes, R; Lambert, K; De Geyter, B; Hassinen, A; Van Thourhout, D; Hens, Z; Rivas, J Gomez

    2013-01-01

    We demonstrate that an array of optical antennas may render a thin layer of randomly oriented semiconductor nanocrystals into an enhanced and highly directional source of polarized light. The array sustains collective plasmonic lattice resonances which are in spectral overlap with the emission of the nanocrystals over narrow angular regions. Consequently, di?fferent photon energies of visible light are enhanced and beamed into def?nite directions.

  4. Influence of the Light Source and Curing Parameters on Microhardness of a Silorane-Based Dental Composite Material

    OpenAIRE

    Malara P.; Czech Z.; Świderski W.

    2016-01-01

    The aim of the study was to determine the influence of the light source and the light-curing parameters (the distance of the material from the light source and time of light-curing) on microhardness of Flitek Silorane dental composite material. Standardized samples of Filtek Silorane material were cured using two types of Light Curing Units (LCUs) – halogen and LED. The distance of the light source and time of curing differed between samples. The Knoop’s microhardness was tested using microha...

  5. A novel method for detecting light source for digital images forensic

    Science.gov (United States)

    Roy, A. K.; Mitra, S. K.; Agrawal, R.

    2011-06-01

    Manipulation in image has been in practice since centuries. These manipulated images are intended to alter facts — facts of ethics, morality, politics, sex, celebrity or chaos. Image forensic science is used to detect these manipulations in a digital image. There are several standard ways to analyze an image for manipulation. Each one has some limitation. Also very rarely any method tried to capitalize on the way image was taken by the camera. We propose a new method that is based on light and its shade as light and shade are the fundamental input resources that may carry all the information of the image. The proposed method measures the direction of light source and uses the light based technique for identification of any intentional partial manipulation in the said digital image. The method is tested for known manipulated images to correctly identify the light sources. The light source of an image is measured in terms of angle. The experimental results show the robustness of the methodology.

  6. Designing display primaries with currently available light sources for UHDTV wide-gamut system colorimetry.

    Science.gov (United States)

    Masaoka, Kenichiro; Nishida, Yukihiro; Sugawara, Masayuki

    2014-08-11

    The wide-gamut system colorimetry has been standardized for ultra-high definition television (UHDTV). The chromaticities of the primaries are designed to lie on the spectral locus to cover major standard system colorimetries and real object colors. Although monochromatic light sources are required for a display to perfectly fulfill the system colorimetry, highly saturated emission colors using recent quantum dot technology may effectively achieve the wide gamut. This paper presents simulation results on the chromaticities of highly saturated non-monochromatic light sources and gamut coverage of real object colors to be considered in designing wide-gamut displays with color filters for the UHDTV.

  7. Development of terminal hair following skin lesion treatments with an intense pulsed light source.

    Science.gov (United States)

    Vlachos, Spiros P; Kontoes, Paraskevas P

    2002-01-01

    Laser and other light sources have been used to treat vascular and pigmented skin lesions and to remove tattoos and unwanted hair, with varying degrees of success and various side effects. It has not yet been reported that hair growth can occur as a side effect of such treatments. In this paper two cases are presented, one port wine stain and one tattoo, that were each treated several times with an intense pulsed light source (IPLS) for removal. Terminal hair, not present before treatment, partially developed in treated areas of both lesions. Local inflammatory reactions are believed to trigger such outcomes.

  8. Energy feedback freeform lenses for uniform illumination of extended light source LEDs.

    Science.gov (United States)

    Li, Zongtao; Yu, Shudong; Lin, Liwei; Tang, Yong; Ding, Xinrui; Yuan, Wei; Yu, Binhai

    2016-12-20

    Using freeform lenses to construct uniform illumination systems is important in light-emitting diode (LED) devices. In this paper, the energy feedback design is used for freeform lens (EFFL) constructions by solving a set of partial differential equations that describe the mapping relationships between the source and the illumination pattern. The simulation results show that the method can overcome the illumination deviation caused by the extended light source (ELS) problem. Furthermore, a uniformity of 95.6% is obtained for chip-on-board (COB) compact LED devices. As such, prototype LEDs manufactured with the proposed freeform lenses demonstrate significant improvements in luminous efficiency and emission uniformity.

  9. Intelligent pulse light source in the performance calibration system of two-dimensional neutron detector

    Science.gov (United States)

    Yang, Lei; Zhao, Xiao-Fang

    2017-07-01

    Chinese Spallation Neutron Source (CSNS) project will use numerous two-dimensional (2D) neutron detectors whose ZnS (Ag) scintillator is doped with 6Li. To ensure the consistency of all neutron detectors, a calibration system for the performance of 2D neutron detectors is designed. For radiation protection, the state control of the radiation source gets more and more strict. It is impossible to directly carry out experiments with massive radioactive particles. Thus, the following scheme has been designed. The controlled pulsed laser light source on a 2D mobile platform is used to replace the neutron bombardment to generate the photon. The pulse signal drives the laser diode to generate pulse light. The pulse light source located on the 2D platform is controlled by the core controller, and goes to the wavelength shift fiber through the optical fiber. The host computer (PC) receives the signal from the electronics system, processes data, and automatically calibrates the performance parameters. As shown by the experimental results, the pulse light source can perfectly meet all requirements of 2D neutron detector calibration system.

  10. Biological stimulation of the Human skin applying health promoting light and plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Awakowicz, P.; Bibinov, N. [Center for Plasma Science and Technology, Ruhr-University, Bochum (Germany); Born, M.; Niemann, U. [Philips Research, Aachen (Germany); Busse, B. [Zell-Kontakt GmbH, Noerten-Hardenberg (Germany); Gesche, R.; Kuehn, S.; Porteanu, H.E. [Ferdinand-Braun-Institut fuer Hoechstfrequenztechnik, Berlin (Germany); Helmke, A. [University of Applied Sciences and Arts, Goettingen (Germany); Kaemling, A.; Wandke, D. [CINOGY GmbH, Duderstadt (Germany); Kolb-Bachofen, V.; Liebmann, J. [Institute for Immunobiology, Heinrich-Heine University, Duesseldorf (Germany); Kovacs, R.; Mertens, N.; Scherer, J. [Aurion Anlagentechnik GmbH, Seligenstadt (Germany); Oplaender, C.; Suschek, C. [Clinic for Plastic Surgery, University Clinic, Aachen (Germany); Vioel, W. [Laser-Laboratorium, Goettingen (Germany); University of Applied Sciences and Arts, Goettingen (Germany)

    2009-10-15

    In the frame of BMBF project ''BioLiP'', new physical treatment techniques aiming at medical treatment of the human skin have been developed. The acronym BioLiP stands for ''Desinfektion, Entkeimung und biologische Stimulation der Haut durch gesundheitsfoerdernde Licht- und Plasmaquellen'' (Disinfection, germ reduction and biological stimulation of the human skin by health promoting light and plasma sources). A source applying a low-temperature dielectric barrier discharge plasma (DBD) has been investigated on its effectiveness for skin disinfection and stimulation of biological material. Alternatively an atmospheric plasma source consisting of a microwave resonator combined with a solid state power oscillator has been examined. This concept which allows for a compact and efficient design avoiding external microwave power supply and matching units has been optimized with respect to nitrogen monoxide (NO) production in high yields. In both cases various application possibilities in the medical and biological domain are opened up. Light sources in the visible spectral range have been investigated with respect to the proliferation of human cell types. Intensive highly selective blue light sources based on LED technology can slow down proliferation rates without inducing toxic effects which offers new opportunities for treatments of so-called hyperproliferative skin conditions (e.g. with psoriasis or in wound healing) using UV-free light. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  11. Simulation of multicomponent light source for optical-electronic system of color analysis objects

    Science.gov (United States)

    Peretiagin, Vladimir S.; Alekhin, Artem A.; Korotaev, Valery V.

    2016-04-01

    Development of lighting technology has led to possibility of using LEDs in the specialized devices for outdoor, industrial (decorative and accent) and domestic lighting. In addition, LEDs and devices based on them are widely used for solving particular problems. For example, the LED devices are widely used for lighting of vegetables and fruit (for their sorting or growing), textile products (for the control of its quality), minerals (for their sorting), etc. Causes of active introduction LED technology in different systems, including optical-electronic devices and systems, are a large choice of emission color and LED structure, that defines the spatial, power, thermal and other parameters. Furthermore, multi-element and color devices of lighting with adjustable illumination properties can be designed and implemented by using LEDs. However, devices based on LEDs require more attention if you want to provide a certain nature of the energy or color distribution at all the work area (area of analysis or observation) or surface of the object. This paper is proposed a method of theoretical modeling of the lighting devices. The authors present the models of RGB multicomponent light source applied to optical-electronic system for the color analysis of mineral objects. The possibility of formation the uniform and homogeneous on energy and color illumination of the work area for this system is presented. Also authors showed how parameters and characteristics of optical radiation receiver (by optical-electronic system) affect on the energy, spatial, spectral and colorimetric properties of a multicomponent light source.

  12. Synchrotron light sources and free-electron lasers accelerator physics, instrumentation and science applications

    CERN Document Server

    Khan, Shaukat; Schneider, Jochen; Hastings, Jerome

    2016-01-01

    Hardly any other discovery of the nineteenth century did have such an impact on science and technology as Wilhelm Conrad Röntgen’s seminal find of the X-rays. X-ray tubes soon made their way as excellent instruments for numerous applications in medicine, biology, materials science and testing, chemistry and public security. Developing new radiation sources with higher brilliance and much extended spectral range resulted in stunning developments like the electron synchrotron and electron storage ring and the freeelectron laser. This handbook highlights these developments in fifty chapters. The reader is given not only an inside view of exciting science areas but also of design concepts for the most advanced light sources. The theory of synchrotron radiation and of the freeelectron laser, design examples and the technology basis are presented. The handbook presents advanced concepts like seeding and harmonic generation, the booming field of Terahertz radiation sources and upcoming brilliant light sources dri...

  13. Matter from light-light scattering via Breit-Wheeler events produced by two interacting Compton sources

    Science.gov (United States)

    Drebot, Illya; Micieli, D.; Milotti, E.; Petrillo, V.; Tassi, E.; Serafini, L.

    2017-04-01

    We present the dimensioning of a photon-photon collider based on Compton gamma sources for the observation of Breit-Wheeler pair production and QED γ γ events. Two symmetric electron beams, generated by photocathodes and accelerated in linacs, produce two gamma ray beams through Compton back scattering with two J-class lasers. Tuning the system energy above the Breit-Wheeler cross section threshold, a flux of electron-positron pairs is generated out of light-light interaction. The process is analyzed by start-to-end simulations. Realistic numbers of the secondary particle yield, referring to existing state-of-the-art set-ups and a discussion of the feasibility of the experiment taking into account the background signal are presented.

  14. The study of LED light source illumination conditions for ideal algae cultivation

    Science.gov (United States)

    Tsai, Chun-Chin; Huang, Chien-Fu; Chen, Cin-Fu; Yue, Cheng-Feng

    2017-02-01

    Utilizing LED light source modules with 3 different RGB colors, the illumination effect of different wavelengths had been investigated on the growth curve of the same kind of micro algae. It was found that the best micro algae culturing status came out with long wavelength light such as red light (650 670 nm). Based on the same condition for a period of 3 weeks , the grown micro algae population density ratio represented by Optical Density (O.D.) ratio is 1?0.4?0.7 corresponding to growth with Red, Green, Blue light sources, respectively. Mixing 3 types and 2 types of LEDs with different parameters, the grown micro algae population densities were compared in terms of O.D. Interestingly enough, different light sources resulted in significant discoloration on micro algae growth, appearing yellow, brown, green, etc. Our experiments results showed such discoloration effect is reversible. Based on the same lighting condition, micro algae growth can be also affected by incubator size, nutrition supply, and temperature variation. In recent years, micro algae related technologies have been international wise a hot topic of energy and environmental protection for research and development institutes, and big energy companies among those developed countries. There will be an economically prosperous future. From this study of LED lighting to ideal algae cultivation, it was found that such built system would be capable of optimizing artificial cultivation system, leading to economic benefits for its continuous development. Since global warming causing weather change, accompanying with reducing energy sources and agriculture growth shortage are all threatening human being survival.

  15. Spectral composition of light sources and insect phototaxis, with an evaluation of existing spectral response models. Journal of Insect Conservation

    NARCIS (Netherlands)

    Grunsven, van R.H.A.; Donners, M.; Boekee, K.; Tichelaar, I.; Geffen, van K.G.; Groenendijk, D.; Berendse, F.; Veenendaal, E.M.

    2014-01-01

    Artificial illumination attracts insects, but to what extent light attracts insects, depends on the spectral composition of the light. Response models have been developed to predict the attractiveness of artificial light sources. In this study we compared attraction of insects by existing light sour

  16. Production of reactive oxygen species from photosensitizers activated with visible light sources available in dental offices.

    Science.gov (United States)

    Bouillaguet, Serge; Wataha, John C; Zapata, Oscar; Campo, Marino; Lange, Norbert; Schrenzel, Jacques

    2010-08-01

    The aim of this study was to assess the ability of commonly available red- or blue-light dental sources to generate reactive oxygen species (ROS) from photosensitive chemicals that might be useful for photodynamic antimicrobial chemotherapy (PACT). Although the use of red diode lasers is well documented, there is limited information on how useful blue-light sources might be for PACT in dental contexts. A diode laser (Periowave; see Table 1 for material and equipment sources) emitting red light (660-675 nm) was used to activate toluidine blue; riboflavin and pheophorbide-a polylysine (pheophorbide-a-PLL) were photoactivated using an Optilux 501 curing unit emitting blue light (380-500 nm). Ozone gas (generated by OzoTop, Tip Top Tips, Rolle, Switzerland), sodium hypochlorite, and hydrogen peroxide were used for comparison. ROS production was estimated using an iodine-triiodide colorimetric assay, and ROS levels were plotted versus concentration of chemicals to determine each chemical's efficiency in ROS production. One-way ANOVA with Tukey post hoc analysis (alpha = 0.05) was used to compare the efficiencies of ROS production for the various chemicals. Sodium hypochlorite, hydrogen peroxide, and ozone gas produced ROS spontaneously, whereas pheophorbide-a-PLL, riboflavin, and toluidine blue required light exposure. The efficiency of ROS production was higher for pheophorbide-a-PLL and toluidine blue than for ozone gas or riboflavin (p < 0.05). Hydrogen peroxide was the least efficient ROS producer. The results of the current study support the use of blue- or red-light-absorbing photosensitizers as candidates to produce ROS for clinical applications. Blue-light photosensitizers were as efficient as red-light photosensitizers in producing ROS and more efficient than the oxidant chemicals currently used for dental disinfection.

  17. Feasibility study of PDT light sources based on lasing action in strongly scattering media

    Science.gov (United States)

    Lilge, Lothar D.; Pang, Gendi; Jonkman, James; Wilson, Brian C.

    1997-05-01

    Lasing action in strongly scattering media containing a fluorescent dye and pumped by a pulsed high peak power laser can be used to produce light sources which may be suitable for surface or intracavity light delivery in photodynamic therapy, eliminating the need for a dye laser to obtain selectable treatment wavelengths. The present study focuses on evaluating the effects, in cylindrical fiber tip sources for interstitial light delivery, of fluorophore concentration and scattering particle density on lasing peak power, emission wavelength and maximum deliverable, clinically useful fluence-rate and radiant exposure. The sources tested are comprised of Rhodamine 640 perchloride incorporated into a TiO2 based scattering matrix in either ethylene glycol or methanol. The cylindrical fiber tips, 10 mm long and 2 mm in diameter, were pumped via a 320 micrometers diameter multimode optical fiber, achieving line narrowing to approximately 7 nm FWHM at approximately 617 nm, using pulse energies of 1.7 mJ, delivered in 10 nsec from a Q-switched, frequency doubled Nd:YAG laser. The results showed the dependence of the total gain length in the pump volume and reabsorption effects in the remaining volume of the fiber tip. Sources capable of delivering sufficient radiant exposure for clinical use were achieved. While these sources are promising, for clinical use of these fiber sources pump lasers delivering MW pulses at high repetition rates are required to achieve acceptable total irradiation times.

  18. LIGHT SOURCE: Design of a new compact THz source based on Smith-Purcell radiation

    Science.gov (United States)

    Dai, Dong-Dong; Bei, Hua; Dai, Zhi-Min

    2009-06-01

    In recent years, people are dedicated to the research work of finding compact THz sources with high emission power. Smith-Purcell radiation is qualified for the possibility of coherent enhancement due to the effect of FEL mechanism. The compact experiment device is expected to produce hundreds mW level THz ray. The electron beam with good quality is provided under the optimized design of the electron gun. Besides, the grating is designed as an oscillator without any external feedbacks. While the beam passes through the grating surface, the beam bunching will be strong and the second harmonics enhancement will be evident, as is seen from the simulation results.

  19. LIGHT SOURCE: A simulation study of Tsinghua Thomson scattering X-ray source

    Science.gov (United States)

    Tang, Chuan-Xiang; Li, Ren-Kai; Huang, Wen-Hui; Chen, Huai-Bi; Du, Ying-Chao; Du, Qiang; Du, Tai-Bin; He, Xiao-Zhong; Hua, Jian-Fei; Lin, Yu-Zhen; Qian, Hou-Jun; Shi, Jia-Ru; Xiang, Dao; Yan, Li-Xin; Yu, Pei-Cheng

    2009-06-01

    Thomson scattering X-ray sources are compact and affordable facilities that produce short duration, high brightness X-ray pulses enabling new experimental capacities in ultra-fast science studies, and also medical and industrial applications. Such a facility has been built at the Accelerator Laboratory of Tsinghua University, and upgrade is in progress. In this paper, we present a proposed layout of the upgrade with design parameters by simulation, aiming at high X-ray pulses flux and brightness, and also enabling advanced dynamics studies and applications of the electron beam. Design and construction status of main subsystems are also presented.

  20. Energy efficiency and color quality limits in artificial light sources emulating natural illumination.

    Science.gov (United States)

    Hertog, Wim; Llenas, Aleix; Quintero, Jesús M; Hunt, Charles E; Carreras, Josep

    2014-12-15

    We present in this work a calculation of the theoretical limits attainable for natural light emulation with regard to the joint optimization of the Luminous Efficacy of Radiation and color fidelity by using multiple reflectance spectra datasets, along with an implementation of a physical device that approaches these limits. A reduced visible spectrum of blackbody radiators is introduced and demonstrated which allows lamps designed to emulate natural light to operate with excellent color fidelity and higher efficiency as compared to full visible spectrum sources. It is shown that even though 3,000K and 5,500K blackbody sources have maximum efficacies of 21 lm/W and 89 lm/W, respectively, reduced-spectrum artificial light sources can exceed those values up to 363 lm/W and 313 lm/W, respectively, while retaining excellent color fidelity. Experimental demonstration approaching these values is accomplished through the design and implementation of a 12-channel light engine which emits arbitrarily-tunable spectra. The color fidelity of the designed spectra is assessed through Color Rendering Maps, showing that color fidelity is preserved uniformly over a large spectral reflectance dataset, unlike other approaches to generate white light.

  1. Optical pumping in a microfabricated Rb vapor cell using a microfabricated Rb discharge light source

    Energy Technology Data Exchange (ETDEWEB)

    Venkatraman, V.; Kang, S.; Affolderbach, C.; Mileti, G., E-mail: gaetano.mileti@unine.ch [Laboratoire Temps-Fréquence, University of Neuchâtel, Neuchâtel 2000 (Switzerland); Shea, H. [Microsystems for Space Technologies Laboratory, Ecole Polytechnique Fédérale de Lausanne (EPFL), Neuchâtel 2002 (Switzerland)

    2014-02-03

    Miniature (light sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm{sup 3} as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm{sup 3} volume) test setup based on the M{sub z} magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors.

  2. Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

    DEFF Research Database (Denmark)

    Zhu, Diling; Feng, Yiping; Stoupin, Stanislav

    2014-01-01

    A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressu...

  3. Finite-key security analysis of quantum key distribution with imperfect light sources

    Science.gov (United States)

    Mizutani, Akihiro; Curty, Marcos; Lim, Charles Ci Wen; Imoto, Nobuyuki; Tamaki, Kiyoshi

    2015-09-01

    In recent years, the gap between theory and practice in quantum key distribution (QKD) has been significantly narrowed, particularly for QKD systems with arbitrarily flawed optical receivers. The status for QKD systems with imperfect light sources is however less satisfactory, in the sense that the resulting secure key rates are often overly dependent on the quality of state preparation. This is especially the case when the channel loss is high. Very recently, to overcome this limitation, Tamaki et al proposed a QKD protocol based on the so-called ‘rejected data analysis’, and showed that its security—in the limit of infinitely long keys—is almost independent of any encoding flaw in the qubit space, being this protocol compatible with the decoy state method. Here, as a step towards practical QKD, we show that a similar conclusion is reached in the finite-key regime, even when the intensity of the light source is unstable. More concretely, we derive security bounds for a wide class of realistic light sources and show that the bounds are also efficient in the presence of high channel loss. Our results strongly suggest the feasibility of long distance provably secure communication with imperfect light sources.

  4. Application of electron linacs in medicine, food sterilization and synchrotron light sources

    Science.gov (United States)

    Tran, Duc-Tien

    1989-04-01

    A review of the state of the art and new trends in electron linac technology is given with emphasis on three particular applications: radiotherapy, food sterilization and synchrotron light sources. The requirements on linac performances that these applications call for, namely energy variation flexibility, high power, high energy and low cost, will open linacs to new applications to come.

  5. Application of electron linacs in medicine, food sterilization and synchrotron light sources

    Energy Technology Data Exchange (ETDEWEB)

    Tran, D.T. (General Electric - CGR MeV, 78 - Buc (France))

    1989-04-01

    A review of the state of the art and new trends in electron linac technology is given with emphasis on three particular applications: radiotherapy, food sterilization and synchrotron light sources. The requirements on linac performances that these applications call for, namely energy variation flexibility, high power, high energy and lost cost, will open lincas to new applications to come. (orig.).

  6. SLStudio: Open-source framework for real-time structured light

    DEFF Research Database (Denmark)

    Wilm, Jakob; Olesen, Oline Vinter; Larsen, Rasmus

    2014-01-01

    An open-source framework for real-time structured light is presented. It is called “SLStudio”, and enables real-time capture of metric depth images. The framework is modular, and extensible to support new algorithms for scene encoding/decoding, triangulation, and aquisition hardware. It is the ai...

  7. 1994 Activity Report, National Synchrotron Light Source. Annual report, October 1, 1993-September 30, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Rothman, E.Z. [ed.

    1995-05-01

    This report is a summary of activities carried out at the National Synchrotron Light Source during 1994. It consists of sections which summarize the work carried out in differing scientific disciplines, meetings and workshops, operations experience of the facility, projects undertaken for upgrades, administrative reports, and collections of abstracts and publications generated from work done at the facility.

  8. Efficient all solid-state continuous-wave yellow-orange light source

    DEFF Research Database (Denmark)

    Janousek, Jiri; Johansson, Sandra; Tidemand-Lichtenberg, Peter;

    2005-01-01

    We present highly efficient sum-frequency generation between two CW IR lasers using periodically poled KTP. The system is based on the 1064 and 1342 nm laser-lines of two Nd:YVO4 lasers. This is an all solid-state light source in the yellow-orange spectral range. The system is optimized in terms...

  9. Cost-effective wavelength selectable light source using DFB fiber laser array

    DEFF Research Database (Denmark)

    Liu, Fenghai; Xueyan, Zheng; Pedersen, Rune Johan Skullerud

    2000-01-01

    A cost-effective wavelength selectable light source comprising a distributed feedback (DFB) fibre laser array is proposed. A large number of wavelengths can be selected via optical space switches using only one shared pump laser. The structure is a good candidate for use as a wavelength selectabl...

  10. Innovative Development of Next Generation and Energy Efficient Solid State Light Sources for General Illumination

    Energy Technology Data Exchange (ETDEWEB)

    Ian Ferguson

    2006-07-31

    This two year program resulted in a novel broadband spectrally dynamic solid state illumination source (BSDLED) that uses a dual wavelength light emitting diode (LED) and combinations of phosphors to create a broadband emission that is real-time controllable. Four major focuses of this work were as follows: (1) creation of a two terminal dual wavelength LED with control of the relative intensities of the two emission peaks, (2) bandgap modeling of the two terminal dual LED to explain operation based on the doping profile, (3) novel use of phosphor combinations with dual LEDs to create a broadband spectral power distribution that can be varied to mimic a blackbody radiator over a certain range and (4) investigation of novel doping schemes to create tunnel junctions or equivalent buried current spreading layers in the III-nitrides. Advances were achieved in each of these four areas which could lead to more efficient solid state light sources with greater functionality over existing devices. The two-terminal BSDLED is an important innovation for the solid-state lighting industry as a variable spectrum source. A three-terminal dual emitter was also investigated and appears to be the most viable approach for future spectrally dynamic solid state lighting sources. However, at this time reabsorption of emission between the two active regions limits the usefulness of this device for illumination applications.

  11. Remote-Time Division Multiplexing of Bending Sensors Using a Broadband Light Source

    Directory of Open Access Journals (Sweden)

    Mikel Bravo

    2012-01-01

    Full Text Available This work experimentally demonstrates a remote sensing network which interrogates bending sensors using time-division multiplexing techniques and a broadband light source. The bending sensors are located 50 km away from the monitoring station. They are based on a simple tie displacement sensor and offer high-resolution measurements of displacement.

  12. Paul Scherrer Institute Scientific Report 1999. Volume VII: Swiss Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Weyer, Heinz Josef; Bugmann, Marlen; Schuetz, Christine [eds.

    2000-07-01

    The Swiss Synchrotron Light Source (SLS) is a medium energy range light source that also provides light with high brilliance in the regime of hard X-rays. It is being constructed at PSI and scheduled to be operational in 2001. The progress of the construction of pre-injector, booster and storage ring as well as some of the details of new features that were adopted for the design and operation of this machine, are described in this annual report for 1999. An overview of the concept and status of the four SLS beamlines and the related infrastructure is also given. The last chapter contains 11 contributions which report on scientific activities of SLS staff members at synchrotron radiation facilities all over the world.

  13. Propagation characteristics of Bessel beams generated by continuous, incoherent light sources.

    Science.gov (United States)

    Altıngöz, Ceren; Yalızay, Berna; Akturk, Selcuk

    2015-08-01

    We investigate the propagation behavior of Bessel beams generated by incoherent, continuous light sources. We perform experiments with narrowband and broadband light emitting diodes, and, for comparison, with a laser diode. We observe that the formation of Bessel beams is affected minimally by temporal coherence, while spatial coherence determines the longitudinal evolution of the beam profile. With spatially incoherent beams, the fringe contrast is comparable to the coherent case at the beginning of the Bessel zone, while it completely fades away by propagation, turning into a cylindrical light pipe. Our results show that beam shaping methods can be extended to cases of limited spatial coherence, paving the way for potential new uses and applications of such sources.

  14. Color holographic display with white light LED source and single phase only SLM.

    Science.gov (United States)

    Kozacki, Tomasz; Chlipala, Maksymilian

    2016-02-08

    This work presents color holographic display, which is based on a single phase only spatial light modulator (SLM). In the display entire area of the SLM is illuminated by an on-axis white light beam generated by a single large LED. The holographic display fully utilizes SLM bandwidth and has capability of full-color, full frame rate imaging of outstanding quality. This is achieved through: (i) optimal use of the source coherence volume, (ii) application of the single white light LED source, (iii) a development of a novel concept of color multiplexing technique with color filter mask in Fourier plane of the SLM, (iv) and a complex coding with improved diffraction efficiency. Within experimental part of the paper we show single color, full-color holographic 2D and 3D images generated for reconstruction depth exceeding 10 cm.

  15. Fully integrated quantum photonic circuit with an electrically driven light source

    Science.gov (United States)

    Khasminskaya, Svetlana; Pyatkov, Felix; Słowik, Karolina; Ferrari, Simone; Kahl, Oliver; Kovalyuk, Vadim; Rath, Patrik; Vetter, Andreas; Hennrich, Frank; Kappes, Manfred M.; Gol'Tsman, G.; Korneev, A.; Rockstuhl, Carsten; Krupke, Ralph; Pernice, Wolfram H. P.

    2016-11-01

    Photonic quantum technologies allow quantum phenomena to be exploited in applications such as quantum cryptography, quantum simulation and quantum computation. A key requirement for practical devices is the scalable integration of single-photon sources, detectors and linear optical elements on a common platform. Nanophotonic circuits enable the realization of complex linear optical systems, while non-classical light can be measured with waveguide-integrated detectors. However, reproducible single-photon sources with high brightness and compatibility with photonic devices remain elusive for fully integrated systems. Here, we report the observation of antibunching in the light emitted from an electrically driven carbon nanotube embedded within a photonic quantum circuit. Non-classical light generated on chip is recorded under cryogenic conditions with waveguide-integrated superconducting single-photon detectors, without requiring optical filtering. Because exclusively scalable fabrication and deposition methods are used, our results establish carbon nanotubes as promising nanoscale single-photon emitters for hybrid quantum photonic devices.

  16. Theory of light emission from a dipole source embedded in a chiral sculptured thin film.

    Science.gov (United States)

    Mackay, Tom G; Lakhtakia, Akhlesh

    2007-10-29

    Developing a theory based on a spectral Green function for light emission from a point-dipole source embedded in a chiral sculptured thin film (CSTF), we found that the intensity and polarization of the emitted light are strongly influenced by the structural handedness of the CSTF as well as the placement and orientation of the source dipole. The emission patterns across both pupils of the dipole-containing CSTF can be explained in terms of the circular Bragg phenomenon exhibited by CSTFs when illuminated by normally as well as obliquely incident plane waves. The emission characteristics augur well for the future of CSTFs as optical biosensors as well as light emitters with controlled circular polarization and bandwidth.

  17. Light sources for high-volume manufacturing EUV lithography: technology, performance, and power scaling

    Science.gov (United States)

    Fomenkov, Igor; Brandt, David; Ershov, Alex; Schafgans, Alexander; Tao, Yezheng; Vaschenko, Georgiy; Rokitski, Slava; Kats, Michael; Vargas, Michael; Purvis, Michael; Rafac, Rob; La Fontaine, Bruno; De Dea, Silvia; LaForge, Andrew; Stewart, Jayson; Chang, Steven; Graham, Matthew; Riggs, Daniel; Taylor, Ted; Abraham, Mathew; Brown, Daniel

    2017-06-01

    Extreme ultraviolet (EUV) lithography is expected to succeed in 193-nm immersion multi-patterning technology for sub-10-nm critical layer patterning. In order to be successful, EUV lithography has to demonstrate that it can satisfy the industry requirements in the following critical areas: power, dose stability, etendue, spectral content, and lifetime. Currently, development of second-generation laser-produced plasma (LPP) light sources for the ASML's NXE:3300B EUV scanner is complete, and first units are installed and operational at chipmaker customers. We describe different aspects and performance characteristics of the sources, dose stability results, power scaling, and availability data for EUV sources and also report new development results.

  18. Photodegradation of Timber of Three Hardwood Species Caused by Different Light Sources

    Directory of Open Access Journals (Sweden)

    TOLVAJ, László

    2012-01-01

    Full Text Available In this study, resistance of black locust, beech and poplar wood to photodegradation was tested, applying sunlight, a xenon lamp and a mercury vapour lamp. The irradiation time was 200 hours for sunlight and the xenon light and 20 hours for the mercury light. The changes were monitored by colour measurements and infrared spectroscopy. The colour change of black locust was more intensive at the beginning of the irradiation than that of the beech and poplar. The degradation of aromatic structure of lignin (absorbing at 1510 and 1596 cm-1 in black locust was minor compared to the same changes of beech and poplar during the first 10 hours. The mercury lamp induced more intensive changes both in colour and in infrared spectrum than the other two light sources. The results show that the high extractive content of black locust absorbs a considerable amount of light radiation protecting the main chemical components of wood.

  19. Integrated Quantum Optics: Experiments towards integrated quantum-light sources and quantum-enhanced sensing

    DEFF Research Database (Denmark)

    Hoff, Ulrich Busk

    The work presented in this thesis is focused on experimental application and generation of continuous variable quantum correlated states of light in integrated dielectric structures. Squeezed states are among the most exploited continuous variable optical states for free-space quantum-enhanced se......The work presented in this thesis is focused on experimental application and generation of continuous variable quantum correlated states of light in integrated dielectric structures. Squeezed states are among the most exploited continuous variable optical states for free-space quantum...... in this thesis: Firstly, we present proof-of-principle demonstration of interfacing squeezed light with an on-chip optomechanical resonator, demonstrating a quantum-enhanced sensitivity to the vibrations of the micromechanical object. Secondly, work on developing an integrated source of squeezed light...

  20. The X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Alonso-Mori, Roberto; Caronna, Chiara; Chollet, Matthieu; Curtis, Robin; Damiani, Daniel S.; Defever, Jim; Feng, Yiping; Flath, Daniel L.; Glownia, James M. [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Lee, Sooheyong [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Hasylab at DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Lemke, Henrik T.; Nelson, Silke; Bong, Eric; Sikorski, Marcin; Song, Sanghoon; Srinivasan, Venkat; Stefanescu, Daniel; Zhu, Diling; Robert, Aymeric, E-mail: aymeric@slac.stanford.edu [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-14

    A description of the X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source is presented. Recent highlights illustrate the coherence properties of the source as well as some recent dynamics measurements and future directions. The X-ray Correlation Spectroscopy instrument is dedicated to the study of dynamics in condensed matter systems using the unique coherence properties of free-electron lasers. It covers a photon energy range of 4–25 keV. The intrinsic temporal characteristics of the Linac Coherent Light Source, in particular the 120 Hz repetition rate, allow for the investigation of slow dynamics (milliseconds) by means of X-ray photon correlation spectroscopy. Double-pulse schemes could probe dynamics on the picosecond timescale. A description of the instrument capabilities and recent achievements is presented.

  1. Mid-IR fiber optic light source around 6 micron through parametric wavelength translation

    CERN Document Server

    Barh, A; Varshney, R K; Pal, B P; Sanghera, J; Shaw, L B; Aggarwal, I D

    2014-01-01

    We report numerically designed highly nonlinear all glass chalcogenide microstructured optical fiber for efficient generation of light around 6 micron through degenerate four wave mixing by considering continuous wave CO laser of 5 to 10 Watts power emitting at 5.6 micron as the pump. By tuning the pump wavelength, pump power, fiber dispersion and nonlinear properties, narrow and broad band mid-IR all-fiber light source could be realized. Parametric amplification of more than 20 decibel is achievable for the narrow band source at 6.46 micron with a maximum power conversion efficiency of 33 percent while amplification of 22 decibel is achievable for a B-band source over the wavelength range of 5 to 6.3 micron with a conversion efficiency of 40 percent.

  2. Influence of Peak Wavelengths on Properties of Mixed-LED White-Light Sources

    Directory of Open Access Journals (Sweden)

    Snjezana Soltic

    2010-01-01

    Full Text Available The purpose of this investigation is to quantify the influence of the peak wavelength shifts in commercially available LEDs on the characteristics of the mixed-LED white-light sources. For this purpose, a tetrachromatic spectrum was optimized and then subjected to deviations in the peak wavelengths. A total of 882 combinations of peak wavelength values were evaluated, and the results are reported in terms of correlated colour temperature, colour-rendering properties, and radiant luminous efficacy. The results show that there can be significant changes in the characteristics of the source under these conditions. Such changes are highly likely to present problems when dealing with applications where an effective and accurate white-light source is important.

  3. The resolution of point sources of light as analyzed by quantum detection theory

    Science.gov (United States)

    Helstrom, C. W.

    1972-01-01

    The resolvability of point sources of incoherent light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

  4. Resolution of point sources of light as analyzed by quantum detection theory.

    Science.gov (United States)

    Helstrom, C. W.

    1973-01-01

    The resolvability of point sources of incoherent thermal light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

  5. Generation of Vector Partially Coherent Optical Sources Using Phase-Only Spatial Light Modulators

    Science.gov (United States)

    Hyde, Milo W.; Bose-Pillai, Santasri; Voelz, David G.; Xiao, Xifeng

    2016-12-01

    A simple and flexible optical system for generating electromagnetic or vector partially coherent sources or beams is presented. The alternative design controls field amplitude (beam shape), coherence, and polarization using only spatial light modulators. This improvement makes the apparatus simpler to construct and significantly increases the flexibility of vector partially coherent source generators by allowing many different types of sources to be produced without changing the physical setup. The system's layout and theoretical foundations are thoroughly discussed. The utility and flexibility of the proposed system are demonstrated by producing a vector Schell-model and non-Schell-model source. The experimental results are compared to theoretical predictions to validate the design. Lastly, design aspects, which must be considered when building a vector partially coherent source generator for a specific application, are discussed.

  6. Comparison of different light sources for trapping Culicoides biting midges, mosquitoes and other dipterans.

    Science.gov (United States)

    González, Mikel; Alarcón-Elbal, Pedro María; Valle-Mora, Javier; Goldarazena, Arturo

    2016-08-15

    The response of Culicoides biting midges, mosquitoes and other dipterans to different wavelengths was evaluated in a farm meadow in northern Spain. A total of 9449 specimens of 23 species of Culicoides, 5495 other ceratopogonids (non-biting midges), 602 culicids and 12428 other mixed dipterans were captured. Centers for Disease Control and Prevention (CDC) suction light traps fitted with five light emitting diodes (LEDs) (white, green, red, blue, ultraviolet) were run for 15 consecutive nights. Significantly more Culicoides were collected in those traps fitted with green, blue or ultraviolet (UV) lights than in red and white-baited LED traps for the most abundant species captured: C. punctatus (37.5%), C. cataneii (26.5%) and C. obsoletus/C. scoticus (20.4%). Similar results were obtained for non-Culicoides ceratopogonids, mosquitoes and other mixed dipterans. Wavelengths in green (570nm) resulted effective for targeting some Culicoides species, culicids and other midges. In a second trial, the effectiveness of 4-W white and UV tubes was compared to traps fitted with UV LED and a standard incandescent light bulb. More specimens of all taxa were collected with fluorescent black light (UV) traps than with the other light sources, except culicids, which were recovered in high numbers from fluorescent white light traps.

  7. Quantitative Analysis of VIIRS DNB Nightlight Point Source for Light Power Estimation and Stability Monitoring

    Directory of Open Access Journals (Sweden)

    Changyong Cao

    2014-12-01

    Full Text Available The high sensitivity and advanced onboard calibration on the Visible Infrared Imaging Radiometer Suite (VIIRS Day/Night Band (DNB enables accurate measurements of low light radiances which leads to enhanced quantitative applications at night. The finer spatial resolution of DNB also allows users to examine social economic activities at urban scales. Given the growing interest in the use of the DNB data, there is a pressing need for better understanding of the calibration stability and absolute accuracy of the DNB at low radiances. The low light calibration accuracy was previously estimated at a moderate 15% using extended sources while the long-term stability has yet to be characterized. There are also several science related questions to be answered, for example, how the Earth’s atmosphere and surface variability contribute to the stability of the DNB measured radiances; how to separate them from instrument calibration stability; whether or not SI (International System of Units traceable active light sources can be designed and installed at selected sites to monitor the calibration stability, radiometric and geolocation accuracy, and point spread functions of the DNB; furthermore, whether or not such active light sources can be used for detecting environmental changes, such as aerosols. This paper explores the quantitative analysis of nightlight point sources, such as those from fishing vessels, bridges, and cities, using fundamental radiometry and radiative transfer, which would be useful for a number of applications including search and rescue in severe weather events, as well as calibration/validation of the DNB. Time series of the bridge light data are used to assess the stability of the light measurements and the calibration of VIIRS DNB. It was found that the light radiant power computed from the VIIRS DNB data matched relatively well with independent assessments based on the in situ light installations, although estimates have to be

  8. Ultrahigh speed endoscopic swept source optical coherence tomography using a VCSEL light source and micromotor catheter

    Science.gov (United States)

    Tsai, Tsung-Han; Ahsen, Osman O.; Lee, Hsiang-Chieh; Liang, Kaicheng; Giacomelli, Michael G.; Potsaid, Benjamin M.; Tao, Yuankai K.; Jayaraman, Vijaysekhar; Kraus, Martin F.; Hornegger, Joachim; Figueiredo, Marisa; Huang, Qin; Mashimo, Hiroshi; Cable, Alex E.; Fujimoto, James G.

    2014-03-01

    We developed an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor based imaging catheter, which provided an imaging speed of 600 kHz axial scan rate and 8 μm axial resolution in tissue. The micromotor catheter was 3.2 mm in diameter and could be introduced through the 3.7 mm accessory port of an endoscope. Imaging was performed at 400 frames per second with an 8 μm spot size using a pullback to generate volumetric data over 16 mm with a pixel spacing of 5 μm in the longitudinal direction. Three-dimensional OCT (3D-OCT) imaging was performed in patients with a cross section of pathologies undergoing standard upper and lower endoscopy at the Veterans Affairs Boston Healthcare System (VABHS). Patients with Barrett's esophagus, dysplasia, and inflammatory bowel disease were imaged. The use of distally actuated imaging catheters allowed OCT imaging with more flexibility such as volumetric imaging in the terminal ileum and the assessment of the hiatal hernia using retroflex imaging. The high rotational stability of the micromotor enabled 3D volumetric imaging with micron scale volumetric accuracy for both en face and cross-sectional imaging. The ability to perform 3D OCT imaging in the GI tract with microscopic accuracy should enable a wide range of studies to investigate the ability of OCT to detect pathology as well as assess treatment response.

  9. The novel stable control scheme of the light source power in the closed-loop fiber optic gyroscope

    Energy Technology Data Exchange (ETDEWEB)

    Ji Zhongxiao [Graduate University of the Chinese Academy of Sciences, Beijing (China); Ma Caiwen, E-mail: jzx@opt.ac.cn [Xi' an Institute of Optics and Precision Mechanics of the Chinese Academy of Sciences, NO.17 Xinxi Road, New Industrial Park, Xi' an Hi-Tech Industrial Development Zone, Xi' an, Shaanxi (China)

    2011-02-01

    The light source power stability of the Fiber-Optic Gyroscope (FOG) affects directly the scale factor and bias stability of FOG. The typical control scheme of the light source power employs an additional photodetector to detect the output power of the light source. When the fiber loss of FOG varied due to the temperature change, the light power in the additional photodetector did not indicate this change, which decreased the control effect. The spike pulse overlapping on the gyro signal denotes potentially the change of the light power and fiber loss. In the novel scheme, the spike pulse is extracted from the gyro signal, and is transformed into the square wave by the differential circuit. According to the change of the square wave amplitude, FOG adjusts the bias current of the light source to keep the stable light power in the signal photodetector. It is a simple and low-cost scheme without an additional photodetector.

  10. Development of a microsecond X-ray protein footprinting facility at the Advanced Light Source

    Science.gov (United States)

    Gupta, Sayan; Celestre, Richard; Petzold, Christopher J.; Chance, Mark R.; Ralston, Corie

    2014-01-01

    X-ray footprinting (XF) is an important structural biology tool used to determine macromolecular conformations and dynamics of both nucleic acids and proteins in solution on a wide range of timescales. With the impending shut-down of the National Synchrotron Light Source, it is ever more important that this tool continues to be developed at other synchrotron facilities to accommodate XF users. Toward this end, a collaborative XF program has been initiated at the Advanced Light Source using the white-light bending-magnet beamlines 5.3.1 and 3.2.1. Accessibility of the microsecond time regime for protein footprinting is demonstrated at beamline 5.3.1 using the high flux density provided by a focusing mirror in combination with a micro-capillary flow cell. It is further reported that, by saturating samples with nitrous oxide, the radiolytic labeling efficiency is increased and the imprints of bound versus bulk water can be distinguished. These results both demonstrate the suitability of the Advanced Light Source as a second home for the XF experiment, and pave the way for obtaining high-quality structural data on complex protein samples and dynamics information on the microsecond timescale. PMID:24971962

  11. Realizing the benefits of restored periodicity in the advanced light source

    Science.gov (United States)

    Robin, D.; Safranek, J.; Decking, W.

    1999-04-01

    An essential feature of third generation storage ring based light sources is the magnetic lattice is designed with a high degree of periodicity. Tracking simulations show that if the periodicity is perturbed (by focusing errors, for example), nonlinear resonances become excited, which causes a reduction in the dynamic aperture. Therefore it is important to have a method to measure and correct perturbed periodicity. In this paper we study the effect of broken and restored periodicity at an actual third generation light source: the Advanced Light Source at Lawrence Berkeley National Laboratory. First, we show that it is possible to accurately determine the storage ring optic and thus the perturbation of the periodicity by fitting measured orbit response matrices. This method allows us to determine individual field gradient errors in quadrupoles and closed orbit errors in sextupoles. By varying individual quadrupole field strengths it is possible to correct the optic, largely restoring the lattice periodicity. A comparison is made of the performance of the storage ring before and after the optic is corrected. Measurements of the electron beam tails and the synchrotron light image reveal a large suppression in resonance excitation after the optic is corrected. Correcting the optic also improves the injection efficiency.

  12. Enhanced Performance of the Advanced Light Source through Periodicity Restoration of the Linear Lattice

    Science.gov (United States)

    Robin, D.; Steier, C.; Safranek, J.; Decking, W.

    2002-01-01

    An essential feature of third generation storage ring based light sources is the magnetic lattice is designed with a high degree of periodicity. Tracking simulations show that if the periodicity is perturbed (by focusing errors for example), non-linear resonances become excited, which causes a reduction in the dynamic aperture. Therefore it is important to have a method to measure and correct perturbed periodicity. In this paper we study the effect of broken and restored periodicity at an actual third generation light source: the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory. First we show that it is possible to accurately determine the storage ring optic and thus the perturbation of the periodicity by fitting measured orbit response matrices. This method allows us to determine individual field gradient errors in quadrupoles and closed orbit errors in sextupoles. By varying individual quadrupole field strengths it is possible to correct the optic, largely restoring the lattice periodicity. A comparison is made of the performance of the ALS before and after the optic is corrected. Measurements of the electron beam tails and the synchrotron light image reveal a large suppression in resonance excitation after the optic is corrected. Correcting the optic also improves the injection efficiency and lifetime.

  13. Wavelength-Tunable Electroluminescent Light Sources from Individual Ga-Doped ZnO Microwires.

    Science.gov (United States)

    Jiang, Mingming; He, Gaohang; Chen, Hongyu; Zhang, Zhenzhong; Zheng, Lingxia; Shan, Chongxin; Shen, Dezhen; Fang, Xiaosheng

    2017-03-07

    Electrically driven wavelength-tunable light emission from biased individual Ga-doped ZnO microwires (ZnO:Ga MWs) is demonstrated. Single crystalline ZnO:Ga MWs with different Ga-doping concentrations have been synthesized using a one-step chemical vapor deposition method. Strong electrically driven light emission from individual ZnO:Ga MW based devices is realized with tunable colors, and the emission region is localized toward the center of the wires. Increasing Ga-doping concentration in the MWs can lead to the redshift of electroluminescent emissions in the visible range. Interestingly, owing to the lack of rectification characteristics, relevant electrical measurement results show that the alternating current-driven light emission functions excellently on the ZnO:Ga MWs. Consequently, individual ZnO:Ga MWs, which can be analogous to incandescent sources, offer unique possibilities for future electroluminescence light sources. This typical multicolor emitter can be used to rival and complement other conventional semiconductor devices in displays and lighting.

  14. Alternatives to Outdoor Daylight Illumination for Photodynamic Therapy—Use of Greenhouses and Artificial Light Sources

    Directory of Open Access Journals (Sweden)

    Catharina M. Lerche

    2016-02-01

    Full Text Available Daylight-mediated photodynamic therapy (daylight PDT is a simple and pain free treatment of actinic keratoses. Weather conditions may not always allow daylight PDT outdoors. We compared the spectrum of five different lamp candidates for indoor “daylight PDT” and investigated their ability to photobleach protoporphyrin IX (PpIX. Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector, white light-emitting diode (LED lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation (UVB radiation passes through the greenhouse glass, so sun protection is not needed.

  15. Alternatives to Outdoor Daylight Illumination for Photodynamic Therapy--Use of Greenhouses and Artificial Light Sources.

    Science.gov (United States)

    Lerche, Catharina M; Heerfordt, Ida M; Heydenreich, Jakob; Wulf, Hans Christian

    2016-02-29

    Daylight-mediated photodynamic therapy (daylight PDT) is a simple and pain free treatment of actinic keratoses. Weather conditions may not always allow daylight PDT outdoors. We compared the spectrum of five different lamp candidates for indoor "daylight PDT" and investigated their ability to photobleach protoporphyrin IX (PpIX). Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector), white light-emitting diode (LED) lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation (UVB) radiation passes through the greenhouse glass, so sun protection is not needed.

  16. On the comparison of energy sources: feasibility of radio frequency and ambient light harvesting

    CERN Document Server

    Korotkevich, Alexander O; Lavrova, Olga; Coutsias, Evangelos

    2015-01-01

    With growing interest in multi source energy harvesting including integrated microchips we propose a comparison of radio frequency (RF) and solar energy sources in a typical city. Harvesting devices for RF and solar energy will be competing for space of a compact micro or nano device as well as for orientation with respect to the energy source. This is why it is important to investigate importance of every source of energy and make a decision whether it will be worthwhile to include such harvesters. We considered theoretically possible irradiance by RF signal in different situations, typical for the modern urban environment and compared it with ambient solar energy sources available through the night, including moon light. Our estimations show that solar light energy dominates by far margin practically all the time, even during the night, if there is a full moon in the absence of clouds. At the same time, in the closed compartments or at the new moon RF harvesting can be beneficial as a source of "free" energ...

  17. Forest Fires as a Possible Source of Isotopically Light Marine Fe Aerosols

    Science.gov (United States)

    Tegler, L. A.; Sherry, A. M.; Romaniello, S. J.; Anbar, A. D.

    2016-12-01

    Iron (Fe) is an important limiting micronutrient for primary productivity in many high-nutrient, low-chlorophyll (HNLC) regions of the ocean. These marine systems receive a significant fraction of their Fe from atmospheric deposition, which is thought to be dominated by mineral dust with an Fe isotopic composition at or above 0‰. However, Mead et al. (2013) observed isotopically light Fe in marine aerosols smaller than 2.5 μm, which is difficult to reconcile with known sources of marine aerosols. Based on previous experimental work, we hypothesize that biomass burning is the source of isotopically light Fe in atmospheric particles and suggest that biomass burning might represent an underappreciated source of Fe to marine ecosystems. While Guelke et al (2007) demonstrated that Fe in agricultural plants is isotopically light, few studies have examined the Fe isotope composition of naturally occurring forests likely to be a significant source of Fe during forest fires. To address this question, we measured the isotopic composition of Ponderosa pine growing in northern Arizona. Ponderosa pine is one the most common forest types in the western US and thus representative of an important North American fire region. Pine needles were chosen because they are susceptible to complete combustion during biomass burning events. To determine the Fe isotopic composition of pine trees, pine needles were sampled at various tree heights. We found that these samples had δ56Fe values between -1.5 and 0‰, indicating that pine needles can be isotopically light compared to local grasses and soil. These results support the hypothesis that biomass burning may contribute isotopically light Fe to marine aerosols.

  18. High-current quasi-square-wave millisecond light source for high-speed photography

    Science.gov (United States)

    Lin, Wenzheng; Jiang, Aibao; Zhuo, Meizhen

    1993-01-01

    A novel powerful strobe for high-speed photography is described which can replace the high power cw light source, to save energy and synchroflash with the camera. In this strobe, three- phase transformerless direct rectifier, high current SCR switch and pre-ionization technique are used so that the energy consumption goes down greatly, and its total weight is less than 25 Kg. Its principal parameters are as follows: average power, 50 KW; light emitting pulse width, 1 - 100 ms; pulse rise time, less than 0.05 ms; pulse fall time, less than 0.1 ms.

  19. Vacuum ultraviolet light source utilizing rare gas scintillation amplification sustained by photon positive feedback

    Science.gov (United States)

    Aprile, Elena (Inventor); Chen, Danli (Inventor)

    1995-01-01

    A source of light in the vacuum ultraviolet (VUV) spectral region includes a reflective UV-sensitive photocathode supported in spaced parallel relationship with a mesh electrode within a rare gas at low pressure. A high positive potential applied to the mesh electrode creates an electric field which causes drifting of free electrons occurring between the electrodes and producing continuous VUV light output by electric field-driven scintillation amplification sustained by positive photon feedback mediated by photoemission from the photocathode. In one embodiment the lamp emits a narrow-band continuum peaked at 175 nm.

  20. LED arrays as cost effective and efficient light sources for widefield microscopy.

    Directory of Open Access Journals (Sweden)

    Dinu F Albeanu

    Full Text Available New developments in fluorophores as well as in detection methods have fueled the rapid growth of optical imaging in the life sciences. Commercial widefield microscopes generally use arc lamps, excitation/emission filters and shutters for fluorescence imaging. These components can be expensive, difficult to maintain and preclude stable illumination. Here, we describe methods to construct inexpensive and easy-to-use light sources for optical microscopy using light-emitting diodes (LEDs. We also provide examples of its applicability to biological fluorescence imaging.

  1. Dual-etalon cavity ring-down frequency-comb spectroscopy with broad band light source

    Science.gov (United States)

    Chandler, David W; Strecker, Kevin E

    2014-04-01

    In an embodiment, a dual-etalon cavity-ring-down frequency-comb spectrometer system is described. A broad band light source is split into two beams. One beam travels through a first etalon and a sample under test, while the other beam travels through a second etalon, and the two beams are recombined onto a single detector. If the free spectral ranges ("FSR") of the two etalons are not identical, the interference pattern at the detector will consist of a series of beat frequencies. By monitoring these beat frequencies, optical frequencies where light is absorbed may be determined.

  2. Full parallax multifocus three-dimensional display using a slanted light source array

    Science.gov (United States)

    Kim, Sung-Kyu; Kim, Eun-Hee; Kim, Dong-Wook

    2011-11-01

    A new multifocus three-dimensional display which gives full parallax monocular depth cue and omni-directional focus is developed with the least parallax images. The key factor of this display system is a slanted array of light-emitting diode light source, not a horizontal array. In this system, defocus effects are experimentally achieved and the monocular focus effect is tested by four parallax images and even two parallax images. The full parallax multifocus three-dimensional display is more applicable to monocular or binocular augmented reality three-dimensional display in the modification to a see-through type.

  3. Automated in-situ optimization of bimorph mirrors at Diamond Light Source

    Science.gov (United States)

    Sutter, John P.; Alcock, Simon G.; Sawhney, Kawal J. S.

    2011-09-01

    Bimorph mirrors are used on many synchrotron beamlines to focus or collimate light. They are highly adaptable because not only their overall figure but also their local slope errors can be corrected. However, the optimization procedure is complex. At Diamond Light Source, highly repeatable and accurate pencil beam measurements are used to determine a mirror's slope errors. These data are then used by automated scripts to calculate the necessary corrections. This procedure may be applied to any type of active mirror, but for hard X-ray mirrors, diffraction from the slits must be considered.

  4. TW Laser system for Thomson scattering X-ray light source at Tsinghua University

    Institute of Scientific and Technical Information of China (English)

    YAN Li-Xin; DU Ying-Chao; DU Qiang; LI Ren-Kai; HUA Jian-Fei; HUANG Wen-Hui; TANG Chuan-Xiang

    2009-01-01

    A TW(Tera Watt)laser system based on Ti:sapphire mainly for the Tsinghua Thomson scattering X-ray light source(TTX)is being built.Both UV(ultraviolet)laser pulse for driving the photocathode radiofrequency(RF)gun and the IR(infrared)laser pulse as the electron-beam-scattered-light are provided by the system.Efforts have also been made in laser pulse shaping and laser beam transport to optimize the high-brightness electron beam production by the photocathode RF gun.

  5. New scheme of the Discrete Sources Method for light scattering analysis of a particle breaking interface

    Science.gov (United States)

    Eremin, Yuri; Wriedt, Thomas

    2014-12-01

    The Discrete Sources Method (DSM) has been modified to analyze polarized light scattering by an axial symmetric penetrable nanoparticle partially embedded into a substrate. The new numerical scheme of the DSM enables to consider scattering from such substrate defects as flat particles, mounds, pits and voids. A detailed description of the numerical scheme is provided. The developed computer model has been employed to investigate scattering from a shallow particle and pit. Simulation results corresponding to the Differential Scattering Cross-Section and the integral response for P/S polarized light are presented.

  6. Physiological and genetic characterization of plant growth and gravitropism in LED light sources

    Science.gov (United States)

    Deitzer, Gerald F.

    1994-01-01

    Among the many problems of growing plants in completely controlled environments, such as those anticipated for the space station and the CELSS program, is the need to provide light that is both adequate for photosynthesis and of proper quality for normal growth and development. NASA scientists and engineers have recently become interested in the possibility of utilizing densely packed, solid state, light emitting diodes (LED's) as a source for this light. Unlike more conventional incandescent or electrical discharge lamps, these sources are highly monochromatic and lack energy in spectral regions thought to be important for normal plant development. In addition, a recent observation by NASA scientist has suggested that infra-red LED's, that are routinely used as photographic safelights for plants grown in darkness, may interact with the ability of plants to detect gravity. In order to establish how plants respond to light from these LED light sources we carried out a series of experiments with known pigment mutants of the model mustard plant, Arabidopsis thaliana, growing in either a gravity field or on a clinostat to simulate a micro-gravity environment. Results indicate that only red light from the 665 nm LED's disrupts the ability of normal wildtype seedlings to detect a gravity stimulus. There was no consistent effect found for the far-red (735 nm) LED's or either of the infrared (880 nm or 935 nm) LED sources but both showed some effect in one or more of the genotypes tested. Of these five members of the phytochrome multigene family in Arabidopsis, only the phytochrome B pigment mutant (hy3) lacked the ability to detect gravity under all conditions. There was no effect of either micro-gravity (clinostat) or the infra-red LED's on the light induced inhibition of hypocotyl elongation. Measurements of the pigment phytochrome in oats also showed no photoconversion by 15 min irradiations with the infra-red LED's. We conclude that phytochrome B is required for the

  7. Analysis of Light Scattering by Nanoobjects on a Plane Surface via Discrete Sources Method

    Science.gov (United States)

    Eremina, Elena; Eremin, Yuri; Wriedt, Thomas

    2012-12-01

    In the last years light scattering by nanostructures is of interest in different areas of science and technology. Analysis of light scattered by nanostructures is an effective tool for a better understanding of their properties. In this work the Discrete Sources Method (DSM) is applied to model light scattering by nanoparticles on a surface. One of attractive features of the DSM is an ability to account for all the features of the modeled system, such as complex refractive index with frequency dispersion of particles and a substrate, scattering interaction of particle and an interface. To demonstrate the variety of possible applications for the DSM, we concentrated on two practical applications. First is light scattering by a nanorod on a surface, which requires the use of a general 3D version of the DSM. The second case discussed in this chapter is light scattering by a nanoshell, which allows the accounting for the axial symmetry of the problem and essential reduction of calculation time. In both cases light scattering characteristics and their dependence on nanostructure characteristics like size, symmetry, incident angle, particle orientation, refractive index and wavelength are analyzed and discussed.

  8. The efficiency of different light sources to polymerize resin cement beneath porcelain laminate veneers.

    Science.gov (United States)

    Usumez, A; Ozturk, A N; Usumez, S; Ozturk, B

    2004-02-01

    Plasma arc light units for curing resin composites have been introduced with the claim of relatively short curing times. The purpose of this study was to evaluate the efficiency of two different light sources to polymerize dual curing resin cement beneath porcelain laminate veneers. Twenty extracted healthy human maxillary centrals were used. Teeth were sectioned 2 mm below the cemento-enamel junction and crown parts were embedded into self-cure acrylic resin, labial surface facing up. Cavity preparation was carried out on labial surfaces. These teeth were divided into two groups of 10 each. The resin cement/veneer combination was exposed to two different photo polymerization units. A conventional halogen light (Hilux 350, Express Dental Products) and a plasma arc light (Power PAC, ADT) were used to polymerize resin cement. Ten specimens were polymerized conventionally (40 s) and the other specimens by plasma arc curing (PAC) (6 s). Two samples from each tooth measuring 1.2 x 1.2 x 5 mm were prepared. These sections were subjected to microshear testing and failure values were recorded. Statistically significant differences were found between the bond strength of veneers exposed to conventional light and PAC unit (P < 0.001). Samples polymerized with halogen light showed better bond strength. The results of this study suggest that the curing efficiency of PAC through ceramic was lower compared with conventional polymerization for the exposure durations tested in this study.

  9. High-power, computer-controlled, light-emitting diode-based light sources for fluorescence imaging and image-guided surgery.

    Science.gov (United States)

    Gioux, Sylvain; Kianzad, Vida; Ciocan, Razvan; Gupta, Sunil; Oketokoun, Rafiou; Frangioni, John V

    2009-01-01

    Optical imaging requires appropriate light sources. For image-guided surgery, in particular fluorescence-guided surgery, a high fluence rate, a long working distance, computer control, and precise control of wavelength are required. In this article, we describe the development of light-emitting diode (LED)-based light sources that meet these criteria. These light sources are enabled by a compact LED module that includes an integrated linear driver, heat dissipation technology, and real-time temperature monitoring. Measuring only 27 mm wide by 29 mm high and weighing only 14.7 g, each module provides up to 6,500 lx of white (400-650 nm) light and up to 157 mW of filtered fluorescence excitation light while maintaining an operating temperature mW/cm2 of 670 nm near-infrared (NIR) fluorescence excitation light, and 14.0 mW/cm2 of 760 nm NIR fluorescence excitation light over a 15 cm diameter field of view. Using this light source, we demonstrated NIR fluorescence-guided surgery in a large-animal model.

  10. Total radiated power, infrared output, and heat generation by cold light sources at the distal end of endoscopes and fiber optic bundle of light cables.

    Science.gov (United States)

    Hensman, C; Hanna, G B; Drew, T; Moseley, H; Cuschieri, A

    1998-04-01

    Skin burns and ignition of drapes have been reported with the use of cold light sources. The aim of the study was to document the temperature generated by cold light sources and to correlate this with the total radiated power and infrared output. The temperature, total radiated power, and infrared output were measured as a function of time at the end of the endoscope (which is inserted into the operative field) and the end of the fiber optic bundle of the light cable (which connects the cable to the light port of the endoscope) using halogen and xenon light sources. The highest temperature recorded at the end of the endoscope was 95 degrees C. The temperature measured at the optical fiber location of the endoscope was higher than at its lens surface (p cables, the temperature reached 225 degrees C within 15 s. The temperature recorded at the optical fiber location of all endoscopes and light cables studied rose significantly over a period of 10 min to reach its maximum (p power. High temperatures are reached by 10 min at the end of fiber optic bundle of light cables and endoscopes with both halogen and xenon light sources. This heat generation is largely due to the radiated power in the visible light spectrum.

  11. Local transverse coupling impedance measurements in a synchrotron light source from turn-by-turn acquisitions

    Science.gov (United States)

    Carlà, Michele; Benedetti, Gabriele; Günzel, Thomas; Iriso, Ubaldo; Martí, Zeus

    2016-12-01

    Transverse beam coupling impedance is a source of beam instabilities that limits the machine performance in circular accelerators. Several beam based techniques have been used to measure the transverse impedance of an accelerator, usually based on the optics distortion produced by the impedance source itself. Beam position monitor turn-by-turn analysis for impedance characterization has been usually employed in large circumference machines, while synchrotron light sources have mainly used slow orbit based techniques. Instead, the work presented in this paper uses for the first time turn-by-turn data at ALBA to advance the measurement technique into the range of the typically small impedance values of modern light sources. We have measured local impedance contributions through the observation of phase advance versus bunch charge using the betatron oscillations excited with a fast dipole kicker. The ALBA beam position monitor system and the precision of the turn-by-turn analysis allowed to characterize the main sources of transverse impedance, in good agreement with the model values, including the impedance of an in-vacuum undulator.

  12. Local transverse coupling impedance measurements in a synchrotron light source from turn-by-turn acquisitions

    Directory of Open Access Journals (Sweden)

    Michele Carlà

    2016-12-01

    Full Text Available Transverse beam coupling impedance is a source of beam instabilities that limits the machine performance in circular accelerators. Several beam based techniques have been used to measure the transverse impedance of an accelerator, usually based on the optics distortion produced by the impedance source itself. Beam position monitor turn-by-turn analysis for impedance characterization has been usually employed in large circumference machines, while synchrotron light sources have mainly used slow orbit based techniques. Instead, the work presented in this paper uses for the first time turn-by-turn data at ALBA to advance the measurement technique into the range of the typically small impedance values of modern light sources. We have measured local impedance contributions through the observation of phase advance versus bunch charge using the betatron oscillations excited with a fast dipole kicker. The ALBA beam position monitor system and the precision of the turn-by-turn analysis allowed to characterize the main sources of transverse impedance, in good agreement with the model values, including the impedance of an in-vacuum undulator.

  13. Low Temperature Epitaxial Growth of Semiconductors Using Synchrotron Radiation as a Light Source

    Institute of Scientific and Technical Information of China (English)

    Qixin GUO; Mitsuhiro NISHIO; Hiroshi OGAWA

    2000-01-01

    Results of our recent experiments relating to the synchrotron radiation (SR) excited growth of Ⅱ-V compounds using metalorganic sources are described. We discuss mainly the growth characteristics of films in addition to the characterization of the deposited films. ZnTe epitaxial layer without carbon and oxygen contamination is attainable even at room temperature using SR as a light source. The quantum yield for forming ZnTe molecules was estimated to be higher than 3%. Through these experiments, we propose that the SR-excited growth is a powerful technique for a novel low temperature growth of compounds.

  14. Omega Dante Soft X-Ray Power Diagnostic Component Calibration at the National Synchrotron Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, K; Weber, F; Dewald, E; Glenzer, S; Landen, O; Turner, R; Waide, P

    2004-04-15

    The Dante soft x-ray spectrometer installed on the Omega laser facility at the Laboratory for Laser Energetics, University of Rochester is a twelve-channel filter-edge defined x-ray power diagnostic. It is used to measure the absolute flux from direct drive, indirect drive (hohlraums) and other plasma sources. Calibration efforts using two beam lines, U3C (50eV-1keV) and X8A (1keV-6keV) at the National Synchrotron Light Source (NSLS) have been implemented to insure the accuracy of these measurements. We have calibrated vacuum x-ray diodes, mirrors and filters.

  15. Omega Dante soft x-ray power diagnostic component calibration at the National Synchrotron Light Source

    Science.gov (United States)

    Campbell, K. M.; Weber, F. A.; Dewald, E. L.; Glenzer, S. H.; Landen, O. L.; Turner, R. E.; Waide, P. A.

    2004-10-01

    The Dante soft x-ray spectrometer, installed on the Omega laser facility at the Laboratory for Laser Energetics, University of Rochester, is a 12-channel filter-edge defined soft x-ray power diagnostic. It is used to measure the spectrally resolved, absolute flux from direct drive, indirect drive (hohlraums) and other plasma sources. Dante component calibration efforts using two beam lines, U3C (50 eV-1 keV) and X8A (1-6 keV) at the National Synchrotron Light Source have been implemented to improve the accuracy of these measurements. We have calibrated metallic vacuum x-ray diodes, mirrors and filters.

  16. Injector Beam Dynamics for a High-Repetition Rate 4th-Generation Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulos, C. F.; Corlett, J.; Emma, P.; Filippetto, D.; Penn, G.; Qiang, J.; Reinsch, M.; Sannibale, F.; Steier, C.; Venturini, M.; Wells, R.

    2013-05-20

    We report on the beam dynamics studies and optimization methods for a high repetition rate (1 MHz) photoinjector based on a VHF normal conducting electron source. The simultaneous goals of beamcompression and reservation of 6-dimensional beam brightness have to be achieved in the injector, in order to accommodate a linac driven FEL light source. For this, a parallel, multiobjective optimization algorithm is used. We discuss the relative merits of different injector design points, as well as the constraints imposed on the beam dynamics by technical considerations such as the high repetition rate.

  17. In situ image segmentation using the convexity of illumination distribution of the light sources.

    Science.gov (United States)

    Zhang, Li

    2008-10-01

    When separating objects from a background in an image, we often meet difficulties in obtaining the precise output due to the unclear edges of the objects, as well as the poor or nonuniform illumination. In order to solve this problem, this paper presents an in situ segmentation method which takes advantages of the distribution feature of illumination of light sources, rather than analyzing the image pixels themselves. After analyzing the convexity of illumination distribution (CID) of point and linear light sources, the paper makes use of the CID features to find pixels belonging to the background. Then some background pixels are selected as control points to reconstruct the image background by means of B-spline; finally, by subtracting the reconstructed background from the original image, global thresholding can be employed to make the final segmentation. Quantitative evaluation experiments are made to test the performance of the method.

  18. Super-resolving multi-photon interferences with independent light sources

    CERN Document Server

    Oppel, Steffen; Kok, Pieter; von Zanthier, Joachim

    2012-01-01

    Multi-photon interferences with indistinguishable photons from independent light sources are at the focus of current research owing to their potential in optical quantum computing, creating remote entanglement for quantum computation and communication, and quantum metrology. The paradigmatic states for multi-photon interference are the highly entangled NOON states, which can be used to achieve increased resolution in spectroscopy, interferometry, lithography, and microscopy. Multi-photon interferences from independent, uncorrelated emitters can also lead to enhanced resolution in metrology and imaging. So far, such interferences have been observed with maximally two independent emitters. Here, we report multi-photon interferences with up to five independent emitters, displaying interference patterns equivalent to those of NOON states. Experimental results with independent thermal light sources confirm this NOON-like modulation. The experiment is an extension of the landmark measurement by Hanbury Brown and Tw...

  19. Single particle imaging with soft x-rays at the Linac Coherent Light Source

    Science.gov (United States)

    Martin, Andrew V.; Andreasson, Jakob; Aquila, Andrew; Bajt, Saša; Barends, Thomas R. M.; Barthelmess, Miriam; Barty, Anton; Benner, W. Henry; Bostedt, Christoph; Bozek, John D.; Bucksbaum, Phillip; Caleman, Carl; Coppola, Nicola; DePonte, Daniel P.; Ekeberg, Tomas; Epp, Sascha W.; Erk, Benjamin; Farquar, George R.; Fleckenstein, Holger; Foucar, Lutz; Frank, Matthias; Gumprecht, Lars; Hampton, Christina Y.; Hantke, Max; Hartmann, Andreas; Hartmann, Elisabeth; Hartmann, Robert; Hau-Riege, Stephan P.; Hauser, Günther; Holl, Peter; Hoemke, André; Jönsson, Olof; Kassemeyer, Stephan; Kimmel, Nils; Kiskinova, Maya; Krasniqi, Faton; Krzywinski, Jacek; Liang, Mengning; Loh, Ne-Te Duane; Lomb, Lukas; Maia, Filipe R. N. C.; Marchesini, Stefano; Messerschmidt, Marc; Nass, Karol; Odic, Duško; Pedersoli, Emanuele; Reich, Christian; Rolles, Daniel; Rudek, Benedikt; Rudenko, Artem; Schmidt, Carlo; Schultz, Joachim; Seibert, M. Marvin; Shoeman, Robert L.; Sierra, Raymond G.; Soltau, Heike; Starodub, Dmitri; Steinbrener, Jan; Stellato, Francesco; Strüder, Lothar; Svenda, Martin; Tobias, Herbert; Ullrich, Joachim; Weidenspointner, Georg; Westphal, Daniel; White, Thomas A.; Williams, Garth; Hajdu, Janos; Schlichting, Ilme; Bogan, Michael J.; Chapman, Henry N.

    2011-06-01

    Results of coherent diffractive imaging experiments performed with soft X-rays (1-2 keV) at the Linac Coherent Light Source are presented. Both organic and inorganic nano-sized objects were injected into the XFEL beam as an aerosol focused with an aerodynamic lens. The high intensity and femtosecond duration of X-ray pulses produced by the Linac Coherent Light Source allow structural information to be recorded by X-ray diffraction before the particle is destroyed. Images were formed by using iterative methods to phase single shot diffraction patterns. Strategies for improving the reconstruction methods have been developed. This technique opens up exciting opportunities for biological imaging, allowing structure determination without freezing, staining or crystallization.

  20. Simulation of the Recharging Method of Implantable Biosensors Based on a Wearable Incoherent Light Source

    Directory of Open Access Journals (Sweden)

    Yong Song

    2014-11-01

    Full Text Available Recharging implantable electronics from the outside of the human body is very important for applications such as implantable biosensors and other implantable electronics. In this paper, a recharging method for implantable biosensors based on a wearable incoherent light source has been proposed and simulated. Firstly, we develop a model of the incoherent light source and a multi-layer model of skin tissue. Secondly, the recharging processes of the proposed method have been simulated and tested experimentally, whereby some important conclusions have been reached. Our results indicate that the proposed method will offer a convenient, safe and low-cost recharging method for implantable biosensors, which should promote the application of implantable electronics.

  1. National Synchrotron Light Source users manual: Guide to the VUV and x-ray beam lines

    Energy Technology Data Exchange (ETDEWEB)

    Gmuer, N.F.; White-DePace, S.M. (eds.)

    1987-08-01

    The success of the National Synchrotron Light Source in the years to come will be based, in large part, on the size of the users community and the diversity of the scientific disciplines represented by these users. In order to promote this philosophy, this National Synchrotron Light Source (NSLS) Users Manual: Guide to the VUV and X-Ray Beam Lines, has been published. This manual serves a number of purposes. In an effort to attract new research, it will present to the scientific community-at-large the current and projected architecture and capabilities of the various VUV and x-ray beam lines and storage rings. We anticipate that this publication will be updated periodically in order to keep pace with the constant changes at the NSLS.

  2. Evaluating Light Source Color Rendition using the IES TM-30-15 Method

    Energy Technology Data Exchange (ETDEWEB)

    Houser, Kevin W.; Royer, Michael P.; David, Aurelien

    2015-11-30

    A system for evaluating the color rendition of light sources was recently published as IES TM-30-15 IES Method for Evaluating Light Source Color Rendition. The system includes a fidelity index (Rf) to quantify similarity to a reference illuminant, a relative-gamut index (Rg) to quantify saturation relative to a reference illuminant, and a color vector icon that visually presents information about color rendition. The calculation employs CAM02-UCS and uses a newly-developed set of reflectance functions, comprising 99 color evaluation samples (CES). The CES were down-selected from 105,000 real object samples and are uniformly distributed in color space (fairly representing different colors) and wavelength space (avoiding artificial increase of color rendition values by selective optimization).

  3. The use of lasers and intense pulsed light sources for the treatment of pigmentary lesions.

    Science.gov (United States)

    Chan, H H L; Kono, T

    2004-10-01

    Lasers and intense pulsed light sources are frequently used for the treatment of pigmented lesions, and the appropriate selection of devices for different lesions is vital to achieving satisfactory clinical outcomes. In dark-skinned patients, the risk of post-inflammatory hyperpigmentation is of particular importance. In general, long-pulse laser and intense pulsed light sources can be effective with a low risk of post-inflammatory hyperpigmentation (PIH) when used for the treatment of lentigines. However, for dermal pigmentation and tattoo, Q-switched lasers are effective, with a lower risk of complications. In the removal of melanocytic nevi, a combined approach with a long-pulse pigmented laser and a Q-switched laser is particularly applicable.

  4. Refurbishment of a used in-vacuum undulator from the National Synchrotron Light Source for the National Synchrotron Light Source-II ring.

    Science.gov (United States)

    Tanabe, Toshiya; Bassan, Harmanpreet; Broadbent, Andrew; Cappadoro, Peter; Escallier, John; Harder, David; Hetzel, Charles; Hidas, Dean; Kitegi, Charles; Kosciuk, Bernard; Musardo, Marco; Kirkland, Johnny

    2017-09-01

    The National Synchrotron Light Source (NSLS) ceased operation in September 2014 and was succeeded by NSLS-II. There were four in-vacuum undulators (IVUs) in operation at NSLS. The most recently constructed IVU for NSLS was the mini-gap undulator (MGU-X25, to be renamed IVU18 for NSLS-II), which was constructed in 2006. This device was selected to be reused for the New York Structural Biology Consortium Microdiffraction beamline at NSLS-II. At the time of construction, IVU18 was a state-of-the-art undulator designed to be operated as a cryogenic permanent-magnet undulator. Due to the more stringent field quality and impedance requirements of the NSLS-II ring, the transition region was redesigned. The control system was also updated to NSLS-II specifications. This paper reports the details of the IVU18 refurbishment activities including additional magnetic measurement and tuning.

  5. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Liang Ying; Zhu, R Y; Liu, D T

    2001-01-01

    Light monitoring will serve as an intercalibration for Compact Muon Solenoid (CMS) lead tungstate crystals in situ at the Large Hadronic Collider, which is crucial for maintaining crystal calorimeter's subpercent constant term in the energy resolution. This paper presents the design of the CMS electromagnetic calorimeter monitoring light source and high-level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of yttrium-doped PbWO/sub 4/ crystals were investigated and were used to study monitoring linearity and sensitivity as a function of wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. (12 refs).

  6. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Li Yuan Zhang; Ren Yuan Zhu; Duncan, Liu

    2000-01-01

    Light monitoring will serve as an inter calibration for the CMS lead tungstate crystals in situ at LHC, which is crucial for maintaining the crystal calorimeter's sub percent constant term in energy resolution. This paper presents the design of the CMS ECAL monitoring light source and high level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of Y doped PbWO/sub 4/ crystals were investigated, and were used to study monitoring linearity and sensitivity as a function of the wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. (13 refs).

  7. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang, L; Wei, Q; Zhu, R Y; Liu, D T

    2002-01-01

    Light monitoring will track variations of the calibration of the CMS lead tungstate crystals in situ at LHC, which is crucial for maintaining crystal calorimeter's subpercent constant term in the energy resolution. This paper presents the design of the CMS ECAL monitoring light source and high level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of yttrium doped PbWO/sub 4/ crystals were investigated, and were used to study monitoring linearity and sensitivity as a function of wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. (13 refs).

  8. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Li Yuan; Zhu Ren Yuan; Liu Dun Can

    2000-01-01

    Light monitoring will serve as an inter calibration for CMS lead tungstate crystals in situ at LHC, which is crucial for maintaining crystal calorimeter's sub percent constant term in the energy resolution. This paper presents the design of the CMS ECAL monitoring light source and high level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of Y doped PbWO//4 crystals were investigated, and were used to study monitoring linearity and sensitivity as a function of the wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. 29 Refs.

  9. Effect of photoperiod, light intensity and carbon sources on biomass and lipid productivities of Isochrysis galbana.

    Science.gov (United States)

    Babuskin, Srinivasan; Radhakrishnan, Kesavan; Babu, Packirisamy Azhagu Saravana; Sivarajan, Meenakshisundaram; Sukumar, Muthusamy

    2014-08-01

    Biomass and lipid productivities of Isochrysis galbana were optimized using nutrients of molasses (4, 8, 12 g l(-1)), glucose (4, 8, 12 g l(-1)), glycerol (4, 8, 12 g l(-1)) and yeast extract (2 g l(-1)). Combinations of carbon sources at different ratios were evaluated in which the alga was grown at three different light intensities (50, 100 and 150 μmol m(-2) s(-1)) under the influence of three different photoperiod cycles (12/12, 18/6 and 24/0 h light/dark). A maximum cell density of 8.35 g l(-1) with 32 % (w/w) lipid was achieved for mixotrophic growth at 100 μmol m(-2) s(-1) and 18/6 h light/dark with molasses/glucose (20:80 w/w). Mixotrophic cultivation using molasses, glucose and glycerol was thus effective for the cultivation of I. galbana.

  10. A Novel Light Source Design for Spectral Tuning in Biomedical Imaging

    CERN Document Server

    Basu, Chandrajit; Meinhardt-Wollweber, Merve; Roth, Bernhard

    2014-01-01

    We propose a novel architecture with a remote phosphor based modular and compact light source in a non-contact dermoscope prototype for skin cancer screening. The spectrum and color temperature of the output light can easily and significantly be changed depending on spectral absorption characteristics of the tissues being imaged. The new system has several advantages compared to state-of-the-art phosphor converted ultra-bright white LEDs, used in a wide range of medical imaging devices, which have a fixed spectrum and color temperature at a given operating point. In particular, the system can more easily be adapted to the requirements originating from different tissues in the human body which have wavelength dependent absorption and reflectivity. This leads to improved contrast for different kinds of imaged tissue components. The concept of such a lighting architecture can be vastly utilized in many other medical imaging devices including endoscopic systems.

  11. Electrically switchable organo-inorganic hybrid for a white-light laser source

    Science.gov (United States)

    Huang, Jui-Chieh; Hsiao, Yu-Cheng; Lin, Yu-Ting; Lee, Chia-Rong; Lee, Wei

    2016-06-01

    We demonstrate a spectrally discrete white-light laser device based on a photonic bandgap hybrid, which is composed of a soft photonic crystal; i.e., a layer of dye-doped cholesteric liquid crystal (CLC), sandwiched between two imperfect but identical, inorganic multilayer photonic crystals. With a sole optical pump, a mono-, bi-, or tri-chromatic laser can be obtained and, through the soft photonic crystal regulated by an applied voltage, the hybrid possesses electrical tunability in laser wavelength. The three emitted spectral peaks originate from two bandedges of the CLC reflection band as well as one of the photonic defect modes in dual-mode lasing. Thanks to the optically bistable nature of CLC, such a white-light laser device can operate in quite an energy-saving fashion. This technique has potential to fulfill the present mainstream in the coherent white-light source.

  12. Concepts for a low emittance-high capacity storage ring for the diamond light source

    CERN Document Server

    Bartolini, Riccardo; Evans, Gwyndaf; Sawhney, Kawal; Zegenhagen, Joerg

    2017-01-01

    The Diamond Light Source is investigating several paths for a possible machine upgrade to Diamond II. The exercise is driven by a joint assessment of the science capabilities opened by a very low emittance ring and the machine design that will underpin them. The consultation is made on a beamline-by-beamline basis and has highlighted a significant preference for lattices that combine both a low emittance and large capacity for IDs.

  13. Low power microwave tests on RF gun prototype of the Iranian Light Source Facility

    Directory of Open Access Journals (Sweden)

    A Sadeghipanah

    2017-08-01

    Full Text Available In this paper, we introduce RF electron gun of Iranian Light Source Facility (ILSF pre-injection system. Design, fabrication and low-power microwave tests results of the prototype RF electron gun have been described in detail. This paper also explains the tuning procedure of the prototype RF electron gun to the desired resonant frequency. The outcomes of this project brighten the path to the fabrication of the RF electron gun by the local industries  

  14. Supercontinuum optimization for dual-soliton based light sources using genetic algorithms in a grid platform

    OpenAIRE

    ARTEAGA SIERRA, FRANCISCO RODRIGO; Milián Enrique, Carles; I. Torres-Gómez; M. Torres-Cisneros; Moltó, Germán; Ferrando Cogollos, Albert

    2014-01-01

    © 2014 Optical Society of America. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modifications of the content of this paper are prohibited We present a numerical strategy to design fiber based dual pulse light sources exhibiting two predefined spectral peaks in the anomalous group velocity dispersion regime. The frequency conversion is based on t...

  15. Simplified Daylight Spectrum Approximation by Blending Two Light Emitting Diode Sources

    Science.gov (United States)

    2012-03-01

    consideration. The coordinates of each reflected spectra within the 1964 CIE W*U*V* uniform color space are then computed. For each standard color patch, a...more current color space, namely the 1976 CIE L*a*b* uniform color space. Finally, the Root Mean Square Error (RMSE) of the Euclidean distances...2] CIE . Method of measuring and specifying color rendering properties of light sources. in CIE Publication 13.3, Vienna, Austria; 1974. [3

  16. Beam heat load investigations with a cold vacuum chamber for diagnostics in a synchrotron light source

    Energy Technology Data Exchange (ETDEWEB)

    Voutta, Robert

    2016-04-22

    The beam heat load is a crucial input parameter for the cryogenic design of superconducting insertion devices. To understand the discrepancies between the predicted heat load of an electron beam to a cold bore and the heat load observed in superconducting devices, a cold vacuum chamber for diagnostics has been built. Extensive beam heat load measurements were performed at the Diamond light source. They are analysed systematically and combined with complementary impedance bench measurements.

  17. Beam heat load investigations with a cold vacuum chamber for diagnostics in a synchrotron light source

    OpenAIRE

    Voutta, Robert

    2016-01-01

    The beam heat load is a crucial input parameter for the cryogenic design of superconducting insertion devices. To understand the discrepancies between the predicted heat load of an electron beam to a cold bore and the heat load observed in superconducting devices, a cold vacuum chamber for diagnostics has been built. Extensive beam heat load measurements were performed at the Diamond light source. They are analysed systematically and combined with complementary impedance bench measurements.

  18. Development of liquid-jet laser-produced plasma light source for EUV lithography

    Science.gov (United States)

    Abe, Tamotsu; Suganuma, Takashi; Imai, Yousuke; Sugimoto, Yukihiko; Someya, Hiroshi; Hoshino, Hideo; Soumagne, Georg; Komori, Hiroshi; Mizoguchi, Hakaru; Endo, Akira; Toyoda, Koichi

    2003-06-01

    The Extreme UV Lithography System Development Association (EUVA) was established in Japan in May 2002 and is supported by the Ministry of Economy, Trade and Industry (METI). EUVA started the light soruce development in September 2002. This development is done by the assocaition members Gigaphoton, Ushio, Komatsu, Canon, Nikon, the National Institute of Advanced Industrial Sciecne and Technology (AIST) and several Japanese universities. The target of the four-year project is the development of a EUV light source with 10W clean focus point power. For the end of the fiscal year 2003 the development of a 4W EUV light source (clean focus point power) is planned. Both, Laser-Produced-Plasma (LPP) and Discharge-Produced-Plasma (DPP) EUV light sources are investigated at first. Our group at the EUVA Hiratsuka R&D Center is working on LPP sources. We are currently focusing on the development of a driver laser and a liquid Xenon plasma target. The laser is a Nd:YAG MOPA (Master Oscillator and Power Amplifier) system oscillating at 1064 nm. Average power, repetition rate and pulse duration of the laser system are 500 Watt, 10 kHa and 30nsec, respectively. The Xenon liquefication system operates at a maximum pressure of 5MPa and a temperature range between 160 K and 190 K. The pressure inside the vacuum chamber is below 0.1Pa during system operation. This paper presents the current status of the EUV system component development as well as first experimental results of generated EUV radiation.

  19. SESAME-A 3rd Generation Synchrotron Light Source for the Middle East

    Science.gov (United States)

    Winick, Herman

    2010-02-01

    Developed under the auspices of UNESCO and modeled on CERN, SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) is an international research center in construction in Jordan. It will enable world class research by scientists from the region, reversing the brain drain. It will also build bridges between diverse societies, contributing to a culture of peace through international cooperation in science. The centerpiece is a synchrotron light source originating from BESSY I, a gift by Germany. The upgraded machine, a 2.5 GeV 3rd Generation Light Source (133m circumference, 26nm-rad emittance and 12 places for insertion devices), will provide light from infra-red to hard X-rays, offering excellent opportunities to train local scientists and attract those working abroad to return. The SESAME Council meets twice each year and presently has nine Members (Bahrain, Cyprus, Egypt, Iran, Israel, Jordan, Pakistan, Palestinian Authority, Turkey). Members have responsibility for the project and provide the annual operations budget (1.5M US dollars in 2009, expected to rise to about 5M when operation starts in 2012-13). Jordan provided the site, building, and infrastructure. A staff of 20 is installing the 0.8 GeV BESSY I injection system. The facility will have the capacity to serve 30 or more experiments operating simultaneously. See www.sesame.org.jo )

  20. Paul Scherrer Institute Scientific Report 2000. Volume VII: Swiss Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Weyer, Heinz Josef; Bugmann, Marlen; Schuetz, Christine [eds.

    2001-07-01

    The Swiss Synchrotron Light Source (SLS) is a medium energy range light source that also provides light with high brilliance in the regime of hard X-rays. It is presently being constructed at PSI. The year 2000 was crucial for maintaining the project milestones with the start of storage ring commissioning for beginning of 2001 and first light on the probe at the four beamlines of phase I for August 2001. The major goals of 2000 were the completion of accelerator installation, the commissioning of linac and booster and the beginning of beamline assembly. In the first half of the year in parallel to the installation, major fabrication procedures were going on, that had to be thoroughly followed up in order to guarantee their completion in time. The overview and detailed description of these developments is supplemented in this annual report by 8 contributions on scientific activities of SLS staff members at synchrotron radiation facilities all over the world. A list of scientific publications in 2000 is also provided.

  1. Progress in characterizing the multidimensional color quality properties of white LED light sources

    Science.gov (United States)

    Teunissen, Kees; Hoelen, Christoph

    2016-03-01

    With the introduction of solid state light sources, the variety in emission spectra is almost unlimited. However, the set of standardized parameters to characterize a white LED light source, such as correlated color temperature (CCT) and CIE general color rendering index (Ra), is known to be limited and insufficient for describing perceived differences between light sources. Several characterization methods have been proposed over the past decades, but their contribution to perceived color quality has not always been validated. To gain more insight in the relevant characteristics of the emission spectra for specific applications, we have conducted a perception experiment to rate the attractiveness of three sets of objects, including fresh food, packaging materials and skin tones. The objects were illuminated with seven different combinations of Red, Green, Blue, Amber and White LEDs, all with the same CCT and illumination level, but with differences in Ra and color saturation. The results show that, in general, object attractiveness does not correlate well with Ra, but shows a positive correlation with saturation increase for two out of three applications. There is no clear relation between saturation and skin tone attractiveness, partly due to differences in preference between males and females. A relative gamut area index (Ga) represents the average change in saturation and a complementary color vector graphic shows the direction and magnitude of chromatic differences for the eight CIE-1974 test-color samples. Together with the CIE general color rendering index (Ra) they provide useful information for designing and optimizing application specific emission spectra.

  2. New ambient pressure photoemission endstation at Advanced Light Source beamline 9.3.2

    KAUST Repository

    Grass, Michael E.

    2010-01-01

    During the past decade, the application of ambient pressure photoemission spectroscopy (APPES) has been recognized as an important in situ tool to study environmental and materials science, energy related science, and many other fields. Several APPES endstations are currently under planning or development at the USA and international light sources, which will lead to a rapid expansion of this technique. The present work describes the design and performance of a new APPES instrument at the Advanced Light Source beamline 9.3.2 at Lawrence Berkeley National Laboratory. This new instrument, Scienta R4000 HiPP, is a result of collaboration between Advanced Light Source and its industrial partner VG-Scienta. The R4000 HiPP provides superior electron transmission as well as spectromicroscopy modes with 16 μm spatial resolution in one dimension and angle-resolved modes with simulated 0.5° angular resolution at 24° acceptance. Under maximum transmission mode, the electron detection efficiency is more than an order of magnitude better than the previous endstation at beamline 9.3.2. Herein we describe the design and performance of the system, which has been utilized to record spectra above 2 mbar. © 2010 American Institute of Physics.

  3. Generating Picosecond X-Ray Pulses with Beam Manipulation in Synchrotron Light Sources

    CERN Document Server

    Guo, Weiming; Harkay, Katherine C; Sajaev, Vadim; Yang Bing Xin

    2005-01-01

    The length of x-ray pulses generated by storage ring light sources is usually tens of picoseconds. For example, the value is 40 ps rms at the Advanced Photon Source (APS). Methods of x-ray pulse compression are of great interest at the APS. One possible method, per Zholents et al., is to tilt the electron bunch with deflecting rf cavities.* Alternately, we found that the electron bunch can develop a tilt after application of a vertical kick in the presence of nonzero chromaticity. After slicing, the x-ray pulse length is determined by the tilt angle and the vertical beam size. In principal, sub-picosecond pulses can be obtained at APS. To date we have observed 6 ps rms visible light pulses with a streak camera. Efforts are underway to attempt further compression of the x-ray pulse and to increase the brilliance. This method can be easily applied to any storage ring light sources to generate x-ray pulses up to two orders of magnitude shorter than the electron bunch length. In this paper, we will present the th...

  4. Shifted excitation resonance Raman difference spectroscopy using a microsystem light source at 488 nm

    Science.gov (United States)

    Maiwald, M.; Sowoidnich, K.; Schmidt, H.; Sumpf, B.; Erbert, G.; Kronfeldt, H.-D.

    2010-04-01

    Experimental results in shifted excitation resonance Raman difference spectroscopy (SERRDS) at 488 nm will be presented. A novel compact diode laser system was used as excitation light source. The device is based on a distributed feedback (DFB) diode laser as a pump light source and a nonlinear frequency doubling using a periodically poled lithium niobate (PPLN) waveguide crystal. All elements including micro-optics are fixed on a micro-optical bench with a footprint of 25 mm × 5 mm. An easy temperature management of the DFB laser and the crystal was used for wavelength tuning. The second harmonic generation (SHG) provides an additional suppression of the spontaneous emission. Raman spectra of polystyrene demonstrate that no laser bandpass filter is needed for the Raman experiments. Resonance-Raman spectra of the restricted food colorant Tartrazine (FD&C Yellow 5, E 102) in distilled water excited at 488 nm demonstrate the suitability of this light source for SERRDS. A limit of detection (LOD) of 0.4 μmol.l-1 of E102 enables SERRDS at 488 nm for trace detection in e.g. food safety control as an appropriate contactless spectroscopic technique.

  5. Acoustic beam steering by light refraction: illustration with directivity patterns of a tilted volume photoacoustic source.

    Science.gov (United States)

    Raetz, Samuel; Dehoux, Thomas; Perton, Mathieu; Audoin, Bertrand

    2013-12-01

    The symmetry of a thermoelastic source resulting from laser absorption can be broken when the direction of light propagation in an elastic half-space is inclined relatively to the surface. This leads to an asymmetry of the directivity patterns of both compressional and shear acoustic waves. In contrast to classical surface acoustic sources, the tunable volume source allows one to take advantage of the mode conversion at the surface to control the directivity of specific modes. Physical interpretations of the evolution of the directivity patterns with the increasing light angle of incidence and of the relations between the preferential directions of compressional- and shear-wave emission are proposed. In order to compare calculated directivity patterns with measurements of normal displacement amplitudes performed on plates, a procedure is proposed to transform the directivity patterns into pseudo-directivity patterns representative of the experimental conditions. The comparison of the theoretical with measured pseudo-directivity patterns demonstrates the ability to enhance bulk-wave amplitudes and to steer specific bulk acoustic modes by adequately tuning light refraction.

  6. The Potential of an Ultimate Storage Ring for Future Light Sources

    Science.gov (United States)

    Bei, M.; Borland, M.; Cai, Y.; Elleaume, P.; Gerig, R.; Harkay, K.; Emery, L.; Hutton, A.; Hettel, R.; Nagaoka, R.; Robin, D.; Steier, C.

    2010-10-01

    This paper is the report of the working group on Ultimate Storage Rings at the Department of Energy's Basic Energy Sciences Workshop on Physics of Future Light Sources, which took place in Gaithersburg, Maryland on September 15-17, 2009. In this report we address the accelerator design issues related to the next generation of storage ring light sources, deemed "ultimate" storage rings. In our estimation, storage rings have the potential to provide an increase in photon brightness and coherent flux that is two orders of magnitude above that projected for rings currently under construction. In addition to photon brightness and coherent flux, we discuss other directions, such as shorter pulses, tailored bunches, and partial lasing, in which rings could evolve. For the most part we envision ultimate storage rings as an evolutionary advance from existing rings that faces no fundamental technological obstacles. Nevertheless we identify several important areas of R&D that should be pursued to enable the realization of the full potential of ultimate ring light sources.

  7. HIGH-PRECISION DETERMINATION OF THE ANGULAR POSITION FOR POINT LIGHT SOURCE WITH CCD-ARRAYS

    Directory of Open Access Journals (Sweden)

    Y. G. Lebedko

    2015-05-01

    Full Text Available Subject of study. A method of angular position measuring for point light source in the system with CCD arrays is proposed by converting of angle – time – code in low light conditions and at high signal / noise ratio. Assessment of the method potential accuracy is given. It is determined by instrumental irremovable random errors of measurement in terms of optimal processing of incoming information with a single reading it with CCD – arrays. Method. This work introduces an optoelectronic system circuit with CCD arrays with stretched sensing elements and a point of reference for angular position measuring. In this case the arrays have images projections of both the reference point source and the target point source, which angular position is measured with high precision. From the CCD array output the signals arrive at an optimal (or apt linear filter, and then to the signal peak position detection circuit. The scheme provides minimum error due to the influence of noise. Pulse edges, corresponding to the signals maximum, make a time interval filled with high-frequency counting pulses. The number of pulses in this interval will correspond to the measured angular position of the target point source. Main results. Analysis of random errors has been carried out in terms of statistical decision theory. Analysis takes into account the spectral function of the signals defined by transfer functions of the optical system and a CCD array as an image analyzer. Research of measurement accuracy is carried out depending on the clock frequency of reading information from CCD arrays for different values of signal-to-noise ratio. It has been shown that even with a single readout with CCD array by the proposed opto-electronic circuit measuring error does not exceed 0.01 of the sensing element size. Practical significance. The results are usable in high-precision measuring opto-electronic systems of star sensors for determining the angular position of the low

  8. Photocatalytic Performance of ZnO: Al Films under Different Light Sources

    Directory of Open Access Journals (Sweden)

    Prashant Pradhan

    2012-01-01

    Full Text Available ZnO and Al doped ZnO films were produced by spray pyrolysis. The films were characterized by X-ray diffraction (XRD, scanning electron microscopy (SEM, UV-vis spectroscopy, and photoluminescence. Their photocatalytic activity was evaluated by the decomposition of the methyl orange dye using different light sources: ultraviolet light, artificial white light, and direct sunlight. The films were also tested under darkness for comparison. The ZnO films were able to degrade the test pollutant under UV and sunlight in more than a 60% after 180 min of irradiation and a scarce degradation was obtained using white light. However, the Al doped ZnO films presented a very high degradation rate not only under UV and sunlight (100% degradation, but also under white light (90% degradation after the same irradiation time. An unexpected high degradation was also obtained in the dark, which indicates that a nonphotonic process is taking place parallel to the photocatalytic process. This can be due to the extra electrons—provided by the aluminum atoms—that migrate to the surface and produce radicals favoring the decomposition process even in the dark. The high activity achieved by the ZnO: Al films under natural conditions can be potentially applied to water treatment processes.

  9. Colored dissolved organic matter in shallow estuaries: relationships between carbon sources and light attenuation

    Science.gov (United States)

    Oestreich, W.K.; Ganju, Neil Kamal; Pohlman, John; Suttles, Steven

    2016-01-01

    Light availability is of primary importance to the ecological function of shallow estuaries. For example, benthic primary production by submerged aquatic vegetation is contingent upon light penetration to the seabed. A major component that attenuates light in estuaries is colored dissolved organic matter (CDOM). CDOM is often measured via a proxy, fluorescing dissolved organic matter (fDOM), due to the ease of in situ fDOM sensor measurements. Fluorescence must be converted to CDOM absorbance for use in light attenuation calculations. However, this CDOM–fDOM relationship varies among and within estuaries. We quantified the variability in this relationship within three estuaries along the mid-Atlantic margin of the eastern United States: West Falmouth Harbor (MA), Barnegat Bay (NJ), and Chincoteague Bay (MD/VA). Land use surrounding these estuaries ranges from urban to developed, with varying sources of nutrients and organic matter. Measurements of fDOM (excitation and emission wavelengths of 365 nm (±5 nm) and 460 nm (±40 nm), respectively) and CDOM absorbance were taken along a terrestrial-to-marine gradient in all three estuaries. The ratio of the absorption coefficient at 340 nm (m−1) to fDOM (QSU) was higher in West Falmouth Harbor (1.22) than in Barnegat Bay (0.22) and Chincoteague Bay (0.17). The CDOM : fDOM absorption ratio was variable between sites within West Falmouth Harbor and Barnegat Bay, but consistent between sites within Chincoteague Bay. Stable carbon isotope analysis for constraining the source of dissolved organic matter (DOM) in West Falmouth Harbor and Barnegat Bay yielded δ13C values ranging from −19.7 to −26.1 ‰ and −20.8 to −26.7 ‰, respectively. Concentration and stable carbon isotope mixing models of DOC (dissolved organic carbon) indicate a contribution of 13C-enriched DOC in the estuaries. The most likely source of 13C-enriched DOC for the systems we investigated is Spartina cordgrass. Comparison of

  10. On the efficiency of stochastic volume sources for the determination of light meson masses

    CERN Document Server

    Endress, E; Wittig, H

    2011-01-01

    We investigate the efficiency of single timeslice stochastic sources for the calculation of light meson masses on the lattice as one varies the quark mass. Simulations are carried out with Nf = 2 flavours of non-perturbatively O(a) improved Wilson fermions for pion masses in the range of 450 - 760 MeV. Results for pseudoscalar and vector meson two-point correlation functions computed using stochastic as well as point sources are presented and compared. At fixed computational cost the stochastic approach reduces the variance considerably in the pseudoscalar channel for all simulated quark masses. The vector channel is more affected by the intrinsic stochastic noise. In order to obtain stable estimates of the statistical errors and a more pronounced plateau for the effective vector meson mass, a relatively large number of stochastic sources must be used.

  11. Source Attribution of Light-absorbing Aerosols in Arctic Snow (Invited)

    Science.gov (United States)

    Hegg, D.; Warren, S. G.; Grenfell, T. C.; Doherty, S. J.; Larson, T. V.; Clarke, A. D.

    2010-12-01

    Light-absorbing aerosols (LAA) deposited on the arctic snow pack, in particular black carbon (BC), contribute appreciably to the arctic radiation budget and their reduction has been suggested as a means to attenuate warming in the arctic. Effective prediction and mitigation of Arctic snow LAA requires that the sources of the LAA be elucidated. To this end, receptor modeling in the form of Positive Matrix Factorization (PMF) has been exercised on a data set of chemical concentrations in snow of various species (including inorganic and organic acids, carbohydrates and selected other organics as well as LAA) derived from an extensive set of snow samples from locations in Russia (including Siberia), Canada, Greenland, the Arctic Ocean and Svalbard. The data were obtained in three distinct periods: spring of 2007, spring of 2008, and spring of 2009. Data from each period were analyzed separately (note that the Svalbard data were analyzed only recently and were not included in the published 2007 analysis). Aerosol light absorption was determined spectrophotometrically at multiple wavelengths on filters through which melted snow was filtered. Based on the Angstrom exponent of the light absorption, partitioning of the absorption between BC and other LAA species was estimated. Statistics of the LAA concentrations for the Arctic as a whole and the geographic distribution of BC and other LAA species are presented. PMF analysis of the filtrate and filters from the 2007 data set from western Siberia, the Canadian lower arctic and Greenland revealed four factors or sources: two distinct biomass burning sources, a pollution source and a marine source. The first three of these were responsible for essentially all of the black carbon, with the two biomass sources together accounting for > 90% of the black carbon. Geographically, the biomass sources were dominant for all regions except the Arctic Ocean near the North Pole. For the 2008 and 2009 data sets, from eastern Siberia and

  12. ECR Light Ion Sources at CEA/Saclay%CEA/Saclay的ECR轻离子离子源

    Institute of Scientific and Technical Information of China (English)

    R.Gobin; P-A.Leroy; O.Tuske; D.Uriot; P-Y.Beauvais; A.Ben Ismail; D.Bogard; O.Delferriere; D.de Menezes; R.Duperrier; Y.Gauthier; F.Harrault

    2007-01-01

    In the beginning of the 90s,T.Taylor and his collaborators demonstrated ECR sources operating at low frequency (I.e.2.45GHz) are able to produce very intense single charge light ion beams.At CEA/Saclay,the SILHI source developments started in 1995.Since 1997 more than 100mA proton or deuteron beams are routinely produced in pulsed or continuous mode.To comply with ADS reliability constraint,important improvements have been performed to increase the installation reliability.Moreover,to optimize the beam transport in the low energy beam line,the extraction system was carefully designed and space charge compensation studies were undertaken.An important step has been reached in 2005 with the development of a permanent magnet source able to produce a total beam of 109mA at 85kV.A new test bench named BETSI,especially dedicated to permanent magnet source developments,is presently under construction.It will allow analysing positive or negative extracted beams up to 50keV and 100mA.In addition,for several years work has been done to optimize the production of negative hydrogen ion beam with such an ECR source.Recent analysis pushed towards the construction of a new set up based on a multicusp magnetic configuration.After a brief overview of the CEA/Saclay source developments,this article will point out on the recent results and present status.

  13. A virtual source pattern method for fluorescence tomography with structured light.

    Science.gov (United States)

    Ducros, Nicolas; D'Andrea, Cosimo; Bassi, Andrea; Valentini, Gianluca; Arridge, Simon

    2012-06-21

    In order to reduce both acquisition and reconstruction times, illumination and detection in fluorescence diffuse optical tomography (FDOT) have recently evolved from a point-based to a pattern-based approach. The use of structured illumination, offering the ability to project any pattern of light onto the object, associated with the compression of the acquired fluorescence images has paved the way for a new generation of fast reconstruction algorithms for FDOT. However, the choice of the most appropriate set of source patterns is still an open problem. Here, the use of typical source patterns is investigated on experimental data. Reconstructions of similar qualities are obtained for the different types of source patterns. We found that the performances of structured illumination are limited by the required positivity of the source patterns. To alleviate this problem, we introduce a novel method, namely the virtual source pattern method, which allows for considering any kind of patterns, e.g., with negative and complex intensities. This new method provides a significant increase of the contrast of the reconstruction and also a reduction of the reconstruction error, especially when virtual wavelet source patterns are considered.

  14. Non-imaging Optics of multi-LED light source for hyperspectral imaging

    Science.gov (United States)

    Islam, Kashif; Gosnell, Martin E.; Ploschner, Martin; Anwer, Ayad G.; Goldys, Ewa M.

    2016-12-01

    The main objective of our work was to design a light source which should be capable to collect and illuminate light of LEDs at the smaller aperture of cone (9mm) which could be either coupled with secondary optics of a microscope or utilized independently for hyperspectral studies. Optimized performance of cone was assessed for different substrates (diffused glass silica, Alumina, Zerodur glass, acrylic plastic) and coating surfaces (white diffused, flat white paint, standard mirror) using a simulation software. The parameters optimized for truncated cone include slanting length and Top Major R (Larger diameter of cone) which were also varied from 10 to 350 mm and 10 to 80 mm respectively. In order to see affect of LED positions on cone efficiency, the positions of LED were varied from central axis to off-axis. Similarly, interLED distance was varied from 2 mm to 6 mm to reckon its effect on the performance of cone. The optimized Slant length (80 mm) and Top Major R (50 mm) were determined for substrates (glass zerodur or acrylic plastic) and coating surface (standard mirror). The output profile of truncated source was found non uniform, which is a typical presentation of non imaging optics problem. The maximum efficiency of cone has been found for LED at the centre and it was found decreasing as LED moves away from the central axis. Moreover, shorter the interLED distance, better is the performance of cone. The primary optics of cone shaped light source is capable to lit visible and UV LEDs in practical design. The optimum parameters obtained through simulations could be implemented in the fabrication procedure if the reflectance of source would have been maintained upto finish level of a standard mirror.

  15. SESAME — A 3rd Generation Synchrotron Light Source for the Middle East

    Science.gov (United States)

    Å°lkü, Dinçer; Rahighi, Javad; Winick, Herman

    2007-01-01

    SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) will be the Middle East's first international research center. It is a cooperative venture by the scientists and governments of the region with founding members Bahrain, Egypt, Israel, Jordan, Pakistan, Palestine Authority, and Turkey. Iran is in the process of finalizing its formal membership. Other countries (Cyprus, Morocco, and the United Arab Emirates) are also expected to join. The permanent Council of member states has full responsibility for the project. Members provide the annual operating budget. Observer countries are Germany, Greece, Italy, Kuwait, Portugal, Russian Federation, Sweden, the UK, and the US. SESAME is being developed under the umbrella of UNESCO. Jordan was selected as the building site. SESAME will offer excellent opportunities for training of Middle East scientists and attract those working abroad to consider returning. SESAME will be a 2.5GeV 3rd Generation light source (emittance 26nm-rad, circumference ˜133m), providing excellent performance for structural molecular biology, molecular environmental science, surface and interface science, microelectromechanical devices, x-ray imaging, archaeological microanalysis, and materials characterization. It will cover a broad spectral range from the infrared to hard x-rays and will have 12 straight sections for insertion devices (average length 2.75m). The injector will be the BESSY I 0.8 GeV booster synchrotron which has been given as a gift from Germany. Four committees advise the Council and assist in developing the technical design, beam lines, user community, and scientific Program. The SESAME building, now in construction with funds and a site provided by Jordan, is scheduled for completion in late 2006 after which the BESSY I injector will be installed. First stored beam in the new 2.5 GeV ring is planned for 2009 with six initial beamlines planned. Some beamlines will be built by member countries

  16. SESAME - A 3rd Generation Synchrotron Light Source for the Middle East

    Science.gov (United States)

    U˝Lkü, Dinçer; Rahighi, Javad; Winick, Herman

    2007-01-01

    SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) will be the Middle East's first international research center. It is a cooperative venture by the scientists and governments of the region with founding members Bahrain, Egypt, Israel, Jordan, Pakistan, Palestine Authority, and Turkey. Iran is in the process of finalizing its formal membership. Other countries (Cyprus, Morocco, and the United Arab Emirates) are also expected to join. The permanent Council of member states has full responsibility for the project. Members provide the annual operating budget. Observer countries are Germany, Greece, Italy, Kuwait, Portugal, Russian Federation, Sweden, the UK, and the US. SESAME is being developed under the umbrella of UNESCO. Jordan was selected as the building site. SESAME will offer excellent opportunities for training of Middle East scientists and attract those working abroad to consider returning. SESAME will be a 2.5GeV 3rd Generation light source (emittance 26nm-rad, circumference ~133m), providing excellent performance for structural molecular biology, molecular environmental science, surface and interface science, microelectromechanical devices, x-ray imaging, archaeological microanalysis, and materials characterization. It will cover a broad spectral range from the infrared to hard x-rays and will have 12 straight sections for insertion devices (average length 2.75m). The injector will be the BESSY I 0.8 GeV booster synchrotron which has been given as a gift from Germany. Four committees advise the Council and assist in developing the technical design, beam lines, user community, and scientific Program. The SESAME building, now in construction with funds and a site provided by Jordan, is scheduled for completion in late 2006 after which the BESSY I injector will be installed. First stored beam in the new 2.5 GeV ring is planned for 2009 with six initial beamlines planned. Some beamlines will be built by member countries

  17. Simple and effective calculations about spectral power distributions of outdoor light sources for computer vision.

    Science.gov (United States)

    Tian, Jiandong; Duan, Zhigang; Ren, Weihong; Han, Zhi; Tang, Yandong

    2016-04-04

    The spectral power distributions (SPD) of outdoor light sources are not constant over time and atmospheric conditions, which causes the appearance variation of a scene and common natural illumination phenomena, such as twilight, shadow, and haze/fog. Calculating the SPD of outdoor light sources at different time (or zenith angles) and under different atmospheric conditions is of interest to physically-based vision. In this paper, for computer vision and its applications, we propose a feasible, simple, and effective SPD calculating method based on analyzing the transmittance functions of absorption and scattering along the path of solar radiation through the atmosphere in the visible spectrum. Compared with previous SPD calculation methods, our model has less parameters and is accurate enough to be directly applied in computer vision. It can be applied in computer vision tasks including spectral inverse calculation, lighting conversion, and shadowed image processing. The experimental results of the applications demonstrate that our calculation methods have practical values in computer vision. It establishes a bridge between image and physical environmental information, e.g., time, location, and weather conditions.

  18. Effect of different light sources on reproductive anatomy and physiology of Japanese quail (Coturnix coturnix japonica).

    Science.gov (United States)

    Bobadilla-Mendez, M F; Rojas-Granados, C P; Andrade, E F; Retes, P L; Ferreira, L G; Alvarenga, R R; Rodriguez-Gil, J E; Fassani, E J; Zangeronimo, M G

    2016-05-01

    Artificial lights are essential for controlling the reproductive tract development of birds during puberty and therefore influence reproductive quality. The aim of this study was to evaluate the effect of different light sources on reproductive anatomic and physiological characteristics of female Japanese quail (Coturnix coturnix japonica). A total of 270 birds from one day of age were housed in a masonry shed divided into six rooms with light isolation. Each room was equipped with a different type of light bulb and contained seven cages with five birds in each. The light bulbs tested were: incandescent; compact fluorescent; and light-emitting diode (LED) in the colors white, blue, red and green. The experimental design was completely randomized with six treatments and seven replications of individual birds each. The anatomic and physiological condition of the birds was evaluated at four, eight and 12 weeks of age. The white LED bulb advanced (P<0.05) the sexual maturity by one week, resulted (P<0.05) in higher live weights and greater weight and relative percentage of ovarian stroma, oviduct and ovarian tissue at eight weeks of age. Higher plasma concentrations of estradiol and lipids were also observed (P<0.05) at eight weeks under the white LED bulb. At 12 weeks of age, the magnum and isthmus folding characteristics were better (P<0.05) with the red LED bulb. In conclusion, the photostimulation with the white LED bulb was more efficient at activating the reproductive cycle, hastening the onset of sexual maturity and increasing the development of reproductive organs after puberty.

  19. A Combined Multiple-SLED Broadband Light Source at 1300 nm for High Resolution Optical Coherence Tomography.

    Science.gov (United States)

    Wang, Hui; Jenkins, Michael W; Rollins, Andrew M

    2008-04-01

    We demonstrate a compact, inexpensive, and reliable fiber-coupled light source with broad bandwidth and sufficient power at 1300 nm for high resolution optical coherence tomography (OCT) imaging in real-time applications. By combining four superluminescent diodes (SLEDs) with different central wavelengths, the light source has a bandwidth of 145 nm centered at 1325 nm with over 10 mW of power. OCT images of an excised stage 30 embryonic chick heart acquired with our combined SLED light source (<5 μm axial resolution in tissue) are compared with images obtained with a single SLED source (~10 μm axial resolution in tissue). The high resolution OCT system with the combined SLED light source provides better image quality (smaller speckle noise) and a greater ability to observe fine structures in the embryonic heart.

  20. A Combined Multiple-SLED Broadband Light Source at 1300 nm for High Resolution Optical Coherence Tomography

    Science.gov (United States)

    Wang, Hui; Jenkins, Michael W.; Rollins, Andrew M.

    2013-01-01

    We demonstrate a compact, inexpensive, and reliable fiber–coupled light source with broad bandwidth and sufficient power at 1300 nm for high resolution optical coherence tomography (OCT) imaging in real-time applications. By combining four superluminescent diodes (SLEDs) with different central wavelengths, the light source has a bandwidth of 145 nm centered at 1325 nm with over 10 mW of power. OCT images of an excised stage 30 embryonic chick heart acquired with our combined SLED light source (<5 μm axial resolution in tissue) are compared with images obtained with a single SLED source (~10 μm axial resolution in tissue). The high resolution OCT system with the combined SLED light source provides better image quality (smaller speckle noise) and a greater ability to observe fine structures in the embryonic heart. PMID:24347689

  1. Harnessing structural darkness in the visible and infrared wavelengths for a new source of light

    KAUST Repository

    Huang, Jianfeng

    2015-10-19

    Engineering broadband light absorbers is crucial to many applications, including energy-harvesting devices and optical interconnects. The performances of an ideal absorber are that of a black body, a dark material that absorbs radiation at all angles and polarizations. Despite advances in micrometre-thick films, the absorbers available to date are still far from an ideal black body. Here, we describe a disordered nanostructured material that shows an almost ideal black-body absorption of 98-99% between 400 and 1,400 nm that is insensitive to the angle and polarization of the incident light. The material comprises nanoparticles composed of a nanorod with a nanosphere of 30 nm diameter attached. When diluted into liquids, a small concentration of nanoparticles absorbs on average 26% more than carbon nanotubes, the darkest material available to date. By pumping a dye optical amplifier with nanosecond pulses of 100 mW power, we harness the structural darkness of the material and create a new type of light source, which generates monochromatic emission (5 nm wide) without the need for any resonance. This is achieved through the dynamics of light condensation in which all absorbed electromagnetic energy spontaneously generates single-colour energy pulses. © 2016 Macmillan Publishers Limited. All rights reserved.

  2. Evaluation of Vickers hardness of bulk-fill composites cured by different light sources

    Science.gov (United States)

    Bakhsh, Turki A.; Yagmoor, Mohammed A.; Alsadi, Fahad M.; Jamleh, Ahmad

    2016-02-01

    [Objective] The current in vitro study was performed to evaluate Vickers hardness (VHN) of two different composite resins that were cured by using two different light curing units. [Materials and Methods] Porcelain tube samplers were used to fabricate composite cylinders from either Tetric Evoceram BulkFill (BF; Ivoclar/Vivadent, USA) or SonicFill composite (SF; Kerr, USA). Each composite type had 12 cylindrical specimens, and each specimen was cured with either Blue-phase N light-cure (Bp; Polywave, Ivoclar/Vivadent, USA) or Elipar S10 (El; Monowave, 3M ESPE, Germany). The VHN data were analyzed and tested by using Mann-Whitney U test at a significance level of 5%. [Results] Statistical analyses demonstrated an interaction between the type of composite and the type of light curing source. Significant differences (Phardness of SF-El and lowest for BF-El. [Conclusions] It can be concluded that the surface hardness of bulk-fill composite is not dependent on the type of light-cure. This research was supported by King Abdulaziz University.

  3. Harnessing structural darkness in the visible and infrared wavelengths for a new source of light

    Science.gov (United States)

    Huang, Jianfeng; Liu, Changxu; Zhu, Yihan; Masala, Silvia; Alarousu, Erkki; Han, Yu; Fratalocchi, Andrea

    2016-01-01

    Engineering broadband light absorbers is crucial to many applications, including energy-harvesting devices and optical interconnects. The performances of an ideal absorber are that of a black body, a dark material that absorbs radiation at all angles and polarizations. Despite advances in micrometre-thick films, the absorbers available to date are still far from an ideal black body. Here, we describe a disordered nanostructured material that shows an almost ideal black-body absorption of 98-99% between 400 and 1,400 nm that is insensitive to the angle and polarization of the incident light. The material comprises nanoparticles composed of a nanorod with a nanosphere of 30 nm diameter attached. When diluted into liquids, a small concentration of nanoparticles absorbs on average 26% more than carbon nanotubes, the darkest material available to date. By pumping a dye optical amplifier with nanosecond pulses of ˜100 mW power, we harness the structural darkness of the material and create a new type of light source, which generates monochromatic emission (˜5 nm wide) without the need for any resonance. This is achieved through the dynamics of light condensation in which all absorbed electromagnetic energy spontaneously generates single-colour energy pulses.

  4. Quantum emitters coupled to circular nanoantennas for high-brightness quantum light sources

    Science.gov (United States)

    Abudayyeh, Hamza A.; Rapaport, Ronen

    2017-09-01

    Engineering the directionality and emission rate of quantum light sources is essential in the development of modern quantum applications. In this work we use numerical calculations to optimise the brightness of a broadband quantum emitter positioned in a hybrid metal-dielectric circular periodic nanoantenna. The optimised structure features a photon collection efficiency of 74 % (82 % ) and a photon flux enhancement of over 10 (6) into a numerical aperture of 0.22 (0.50), respectively, corresponding to a direct coupling into two types of multi-mode fibres. To enhance the emission rate, we present a new circular nanoantenna design where a quantum emitter is attached to a silver nanocone at the centre of the antenna. After optimisation, we find a collection efficiency of 61 % (78 % ) into a numerical aperture of 0.22 (0.50), giving a brightness enhancement of 1000 (600) for an unpolarised emitter. The enhancements in both structures are broadband due to the low-quality factor of the device and are therefore ideal for room-temperature sources. This type of a scalable design can be utilised towards on-chip, high-brightness quantum light sources operating at room temperature.

  5. Evaluating scintillator performance in time-resolved hard X-ray studies at synchrotron light sources

    Energy Technology Data Exchange (ETDEWEB)

    Rutherford, Michael E.; Chapman, David J.; White, Thomas G. [Imperial College London, London (United Kingdom); Drakopoulos, Michael [Diamond Light Source, I12 Joint Engineering, Environmental, Processing (JEEP) Beamline, Didcot, Oxfordshire (United Kingdom); Rack, Alexander [European Synchrotron Radiation Facility, Grenoble (France); Eakins, Daniel E., E-mail: d.eakins@imperial.ac.uk [Imperial College London, London (United Kingdom)

    2016-03-24

    Scintillator performance in time-resolved, hard, indirect detection X-ray studies on the sub-microsecond timescale at synchrotron light sources is reviewed, modelled and examined experimentally. LYSO:Ce is found to be the only commercially available crystal suitable for these experiments. The short pulse duration, small effective source size and high flux of synchrotron radiation is ideally suited for probing a wide range of transient deformation processes in materials under extreme conditions. In this paper, the challenges of high-resolution time-resolved indirect X-ray detection are reviewed in the context of dynamic synchrotron experiments. In particular, the discussion is targeted at two-dimensional integrating detector methods, such as those focused on dynamic radiography and diffraction experiments. The response of a scintillator to periodic synchrotron X-ray excitation is modelled and validated against experimental data collected at the Diamond Light Source (DLS) and European Synchrotron Radiation Facility (ESRF). An upper bound on the dynamic range accessible in a time-resolved experiment for a given bunch separation is calculated for a range of scintillators. New bunch structures are suggested for DLS and ESRF using the highest-performing commercially available crystal LYSO:Ce, allowing time-resolved experiments with an interframe time of 189 ns and a maximum dynamic range of 98 (6.6 bits)

  6. Steady State Microbunching for High Brilliance and High Repetition Rate Storage Ring-Based Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alex; Ratner, Daniel; /SLAC; Jiao, Yi; /Beijing, Inst. High Energy Phys.

    2012-09-06

    Electron-based light sources have proven to be effective sources of high brilliance, high frequency radiation. Such sources are typically either linac-Free Electron Laser (FEL) or storage ring types. The linac-FEL type has high brilliance (because the beam is microbunched) but low repetition rate. The storage ring type has high repetition rate (rapid beam circulation) but comparatively low brilliance or coherence. We propose to explore the feasibility of a microbunched beam in a storage ring that promises high repetition rate and high brilliance. The steady-state-micro-bunch (SSMB) beam in storage ring could provide CW sources for THz, EUV, or soft X-rays. Several SSMB mechanisms have been suggested recently, and in this report, we review a number of these SSMB concepts as promising directions for high brilliance, high repetition rate light sources of the future. The trick of SSMB lies in the RF system, together with the associated synchrotron beam dynamics, of the storage ring. Considering various different RF arrangements, there could be considered a number of scenarios of the SSMB. In this report, we arrange these scenarios more or less in order of the envisioned degree of technical challenge to the RF system, and not in the chronological order of their original references. Once the stored beam is steady-state microbunched in a storage ring, it passes through a radiator repeatedly every turn (or few turns). The radiator extracts a small fraction of the beam energy as coherent radiation with a wavelength corresponding to the microbunched period of the beam. In contrast to an FEL, this radiator is not needed to generate the microbunching (as required e.g. by SASE FELs or seeded FELs), so the radiator can be comparatively simple and short.

  7. Steady State Microbunching for High Brilliance and High Repetition Rate Storage Ring-Based Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alex; Ratner, Daniel; /SLAC; Jiao, Yi; /Beijing, Inst. High Energy Phys.

    2012-09-06

    Electron-based light sources have proven to be effective sources of high brilliance, high frequency radiation. Such sources are typically either linac-Free Electron Laser (FEL) or storage ring types. The linac-FEL type has high brilliance (because the beam is microbunched) but low repetition rate. The storage ring type has high repetition rate (rapid beam circulation) but comparatively low brilliance or coherence. We propose to explore the feasibility of a microbunched beam in a storage ring that promises high repetition rate and high brilliance. The steady-state-micro-bunch (SSMB) beam in storage ring could provide CW sources for THz, EUV, or soft X-rays. Several SSMB mechanisms have been suggested recently, and in this report, we review a number of these SSMB concepts as promising directions for high brilliance, high repetition rate light sources of the future. The trick of SSMB lies in the RF system, together with the associated synchrotron beam dynamics, of the storage ring. Considering various different RF arrangements, there could be considered a number of scenarios of the SSMB. In this report, we arrange these scenarios more or less in order of the envisioned degree of technical challenge to the RF system, and not in the chronological order of their original references. Once the stored beam is steady-state microbunched in a storage ring, it passes through a radiator repeatedly every turn (or few turns). The radiator extracts a small fraction of the beam energy as coherent radiation with a wavelength corresponding to the microbunched period of the beam. In contrast to an FEL, this radiator is not needed to generate the microbunching (as required e.g. by SASE FELs or seeded FELs), so the radiator can be comparatively simple and short.

  8. Environmental friendly high efficient light source. Plasma lamp. 2006 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Courret, G.

    2006-07-01

    This annual report for 2006 for the Swiss Federal Office of Energy (SFOE) reports on work being done on the development of a high-efficiency source of light based on the light emission of a plasma. The report presents a review of work done in 2006, including thermodynamics and assessment of the efficiency of the magnetron, tests with small bulbs, study of the standing wave ratio (microwave fluxes) and the development of a new coupling system to allow ignition in very small bulbs. Also, knowledge on the fillings of the bulb and induced effects of the modulator were gained. The development of a second generation of modulator to obtain higher efficiency at lower power is noted.

  9. Development of Laser Light Sources for Trapping Radioactive Francium Atoms Toward Tests of Fundamental Symmetries

    Science.gov (United States)

    Harada, Ken-ichi; Ezure, Saki; Hayamizu, Tomohiro; Kato, Ko; Kawamura, Hirokazu; Inoue, Takeshi; Arikawa, Hiroshi; Ishikawa, Taisuke; Aoki, Takahiro; Uchiyama, Aiko; Itoh, Masatoshi; Ando, Shun; Aoki, Takatoshi; Hatakeyama, Atsushi; Hatanaka, Kichiji; Imai, Kenichi; Murakami, Tetsuya; Shimizu, Yasuhiro; Sato, Tomoya; Wakasa, Tomotsugu; Yoshida, Hidetomo P.; Sakemi, Yasuhiro

    We have developed laser light sources and a magneto-optical trap system for cooling and trapping radioactive francium (Fr) atoms. Because Fr is the heaviest alkali element, a Fr atom exhibits high sensitivity to symmetry violation effects such as atomic parity nonconservation (APNC) and the electron electric dipole moment (eEDM). A laser cooling and trapping technique reduces the systematic errors due to the Doppler effect and the motion-induced magnetic field effect caused by the velocity of atoms. Thus, optically cooled and trapped Fr atoms are among a few promising candidates considered for APNC and eEDM measurements. Frequency stabilization of laser light is required for any stable measurement involving trapped radioactive atoms, including Fr. Since the hyperfine splitting in iodine molecules (127I2) is close to the resonance frequency of the Fr D2 line, we performed frequency modulation spectroscopy of hyperfine structures of I2.

  10. A nano-graphite cold cathode for an energy-efficient cathodoluminescent light source

    Directory of Open Access Journals (Sweden)

    Alexander N. Obraztsov

    2013-08-01

    Full Text Available The development of new types of light sources is necessary in order to meet the growing demands of consumers and to ensure an efficient use of energy. The cathodoluminescence process is still under-exploited for light generation because of the lack of cathodes suitable for the energy-efficient production of electron beams and appropriate phosphor materials. In this paper we propose a nano-graphite film material as a highly efficient cold cathode, which is able to produce high intensity electron beams without energy consumption. The nano-graphite film material was produced by using chemical vapor deposition techniques. Prototypes of cathodoluminescent lamp devices with a construction optimized for the usage of nano-graphite cold cathodes were developed, manufactured and tested. The results indicate prospective advantages of this type of lamp and the possibility to provide advanced power efficiency as well as enhanced spectral and other characteristics.

  11. Spectroscopic and mechanical properties of dental resin composites cured with different light sources

    Science.gov (United States)

    Conti, C.; Giorgini, E.; Landi, L.; Putignano, A.; Tosi, Giorgio

    2005-06-01

    The aim of this study was to determine the effectiveness of polymerization in order to achieve an adequate clinical composite filling. Photopolymerization of new micro matrix restorative resin composite, Esthet-x, shade A3, from Dentsply Corp., was performed with plasma xenon, halogen and light emitting diode (LED) lamps. The degree of conversion (DC) of the resins was determined by means of middle, near infrared and Raman spectroscopy in transmittance and in DRIFT modes. The resin conversion was influenced by the nature of the light source, the distance from the irradiated surface, the exposure time and the depth from the surface. High DC values were obtained with all lamps but they resulted almost constant with the depth only in the LED unit. Micro-hardness and differential thermal analysis were in satisfactory agreement with DC data.

  12. ESS-Bilbao light-ion linear accelerator and neutron source: design and applications

    Science.gov (United States)

    Abad, E.; Arredondo, I.; Badillo, I.; Belver, D.; Bermejo, F. J.; Bustinduy, I.; Cano, D.; Cortazar, D.; de Cos, D.; Djekic, S.; Domingo, S.; Echevarria, P.; Eguiraun, M.; Etxebarria, V.; Fernandez, D.; Fernandez, F. J.; Feuchtwanger, J.; Garmendia, N.; Harper, G.; Hassanzadegan, H.; Jugo, J.; Legarda, F.; Magan, M.; Martinez, R.; Megia, A.; Muguira, L.; Mujika, G.; Muñoz, J. L.; Ortega, A.; Ortega, J.; Perlado, M.; Portilla, J.; Rueda, I.; Sordo, F.; Toyos, V.; Vizcaino, A.

    2011-10-01

    The baseline design for the ESS-Bilbao light-ion linear accelerator and neutron source has been completed and the normal conducting section of the linac is at present under construction. The machine has been designed to be compliant with ESS specifications following the international guidelines of such project as described in Ref. [1]. The new accelerator facility in Bilbao will serve as a base for support of activities on accelerator physics carried out in Spain and southern Europe in the frame of different ongoing international collaborations. Also, a number of applications have been envisaged in the new Bilbao facility for the outgoing light ion beams as well as from fast neutrons produced by low-energy neutron-capture targets, which are briefly described.

  13. Ikeda-like chaos on a dynamically filtered supercontinuum light source

    Science.gov (United States)

    Chembo, Yanne K.; Jacquot, Maxime; Dudley, John M.; Larger, Laurent

    2016-08-01

    We demonstrate temporal chaos in a color-selection mechanism from the visible spectrum of a supercontinuum light source. The color-selection mechanism is governed by an acousto-optoelectronic nonlinear delayed-feedback scheme modeled by an Ikeda-like equation. Initially motivated by the design of a broad audience live demonstrator in the framework of the International Year of Light 2015, the setup also provides a different experimental tool to investigate the dynamical complexity of delayed-feedback dynamics. Deterministic hyperchaos is analyzed here from the experimental time series. A projection method identifies the delay parameter, for which the chaotic strange attractor originally evolving in an infinite-dimensional phase space can be revealed in a two-dimensional subspace.

  14. Counter-facing plasma focus system as an efficient and long-pulse EUV light source

    Science.gov (United States)

    Kuwabara, H.; Hayashi, K.; Kuroda, Y.; Nose, H.; Hotozuka, K.; Nakajima, M.; Horioka, K.

    2011-04-01

    A plasma focus system composed of a pair of counter-facing coaxial plasma guns is proposed as a long-pulse and efficient EUV light source. A proof-of-concept experiment demonstrated that with an assist of breakdown and outer electrode connections, current sheets evolved into a configuration for stable plasma confinement at the center of the electrode. The current sheets could successively compress and confine the high energy density plasma every half period of the discharge current, enabling highly repetitive light emissions in extreme ultraviolet region with time duration in at least ten microseconds for Xe plasma. Also, we confirmed operations of our system for Li plasma. We estimated the highest EUV energy in Li plasma operation at 93mJ/4π sr per 2% bandwidth per pulse.

  15. Influence of the correlated color temperature of a light source on the color discrimination capacity of the observer.

    Science.gov (United States)

    Pardo, Pedro J; Cordero, Eduardo M; Suero, María Isabel; Pérez, Ángel L

    2012-02-01

    It is well known that there are different preferences in correlated color temperature of light sources for daily living activities or for viewing artistic paintings. There are also data relating the capacity of observers to make judgments on color differences with the spectral power distribution of the light source used. The present work describes a visual color discrimination experiment whose results confirm the existence of a relationship between the correlated color temperature of a light source and the color discrimination capacities of the observers.

  16. Lighting

    Data.gov (United States)

    Federal Laboratory Consortium — Lighting Systems Test Facilities aid research that improves the energy efficiency of lighting systems. • Gonio-Photometer: Measures illuminance from each portion of...

  17. High flux, narrow bandwidth compton light sources via extended laser-electron interactions

    Science.gov (United States)

    Barty, V P

    2015-01-13

    New configurations of lasers and electron beams efficiently and robustly produce high flux beams of bright, tunable, polarized quasi-monoenergetic x-rays and gamma-rays via laser-Compton scattering. Specifically, the use of long-duration, pulsed lasers and closely-spaced, low-charge and low emittance bunches of electron beams increase the spectral flux of the Compton-scattered x-rays and gamma rays, increase efficiency of the laser-electron interaction and significantly reduce the overall complexity of Compton based light sources.

  18. Overview of Accelerator Physics Studies and High Level Software for the Diamond Light Source

    CERN Document Server

    Bartolini, Riccardo; Belgroune, Mahdia; Christou, Chris; Holder, David J; Jones, James; Kempson, Vince; Martin, Ian; Rowland, James H; Singh, Beni; Smith, Susan L; Varley, Jennifer Anne; Wyles, Naomi

    2005-01-01

    DIAMOND is a 3 GeV synchrotron light source under construction at Rutherford Appleton Laboratory in Oxfordshire (UK). The accelerators complex consists of a 100 MeV LINAC, a full energy booster and a 3GeV storage ring with 22 straight sections available for IDs. Installation of all three accelerators has begun, and LINAC commissioning is due to start in Spring 2005. This paper will give an overview of the accelerator physics activity to produce final layouts and prepare for the commissioning of the accelerator complex. The DIAMOND facility is expected to be operational for users in 2007

  19. The Coherent X-ray Imaging instrument at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Mengning; Williams, Garth J.; Messerschmidt, Marc; Seibert, M. Marvin; Montanez, Paul A.; Hayes, Matt; Milathianaki, Despina; Aquila, Andrew; Hunter, Mark S.; Koglin, Jason E.; Schafer, Donald W.; Guillet, Serge; Busse, Armin; Bergan, Robert; Olson, William; Fox, Kay; Stewart, Nathaniel; Curtis, Robin; Miahnahri, Alireza Alan; Boutet, Sébastien, E-mail: sboutet@slac.stanford.edu [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-15

    Description of the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source. Recent scientific highlights illustrate the femtosecond crystallography, high power density and extreme matter capabilities of the CXI instrument. The Coherent X-ray Imaging (CXI) instrument specializes in hard X-ray, in-vacuum, high power density experiments in all areas of science. Two main sample chambers, one containing a 100 nm focus and one a 1 µm focus, are available, each with multiple diagnostics, sample injection, pump–probe and detector capabilities. The flexibility of CXI has enabled it to host a diverse range of experiments, from biological to extreme matter.

  20. Efficiency and stability of a phosphor-conversion white light source using a blue laser diode

    Directory of Open Access Journals (Sweden)

    G. Ledru

    2014-10-01

    Full Text Available A white light source using direct phosphor-conversion excited by a blue laser diode is presented. In this preliminary study we have investigated the influence of phosphor’s thickness and operating current of the laser diode over the (x, y chromaticity coordinates, Correlated Color Temperature (CCT and Color Rendering Index (CRI. The best values found were 4000 K and 94. A 40 lm/W luminous efficacy was achieved together with a CRI close to 90 for an operating current of 0.8 A. Those values, to the best of our knowledge, were not previously reported in the literature.

  1. Beam shaping to improve the free-electron laser performance at the Linac Coherent Light Source

    Science.gov (United States)

    Ding, Y.; Bane, K. L. F.; Colocho, W.; Decker, F.-J.; Emma, P.; Frisch, J.; Guetg, M. W.; Huang, Z.; Iverson, R.; Krzywinski, J.; Loos, H.; Lutman, A.; Maxwell, T. J.; Nuhn, H.-D.; Ratner, D.; Turner, J.; Welch, J.; Zhou, F.

    2016-10-01

    A new operating mode has been developed for the Linac Coherent Light Source (LCLS) in which we shape the longitudinal phase space of the electron beam. This mode of operation is realized using a horizontal collimator located in the middle of the first bunch compressor to truncate the head and tail of the beam. With this method, the electron beam longitudinal phase space and current profile are reshaped, and improvement in lasing performance can be realized. We present experimental studies at the LCLS of the beam shaping effects on the free-electron laser performance.

  2. Measurements and simulations of ultralow emittance and ultrashort electron beams in the linac coherent light source.

    Science.gov (United States)

    Ding, Y; Brachmann, A; Decker, F-J; Dowell, D; Emma, P; Frisch, J; Gilevich, S; Hays, G; Hering, Ph; Huang, Z; Iverson, R; Loos, H; Miahnahri, A; Nuhn, H-D; Ratner, D; Turner, J; Welch, J; White, W; Wu, J

    2009-06-26

    The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser project presently in a commissioning phase at the SLAC National Accelerator Laboratory. We report here on very low-emittance measurements made at low bunch charge, and a few femtosecond bunch length produced by the LCLS bunch compressors. Start-to-end simulations associated with these beam parameters show the possibilities of generating hundreds of GW at 1.5 A x-ray wavelength and nearly a single longitudinally coherent spike at 1.5 nm with 2-fs duration.

  3. Structural color analysis of the photoresist grating influenced by the light source and its parameters.

    Science.gov (United States)

    Zeng, Siwei; Liu, Zhengkun; Qiu, Keqiang; Liu, Ying; Xu, Xiangdong; Fu, Shaojun

    2017-03-01

    The basic principle and method to generate structural color from the photoresist grating of the multilayer dielectric diffraction grating are introduced. Rigorous coupled-wave analysis is used for computation with the open software RCWA-1D. The relationships between the characteristics of the photoresist and the structural color are explained. This paper discusses the effect of light source characteristics on the duty cycle color resolution, indicating that TE polarization is better than TM polarization, and the FWHM should be sufficiently large with an optimized value for the incident angle.

  4. Scanning soft X-ray spectromicroscopy at the Pohang Light Source: commissioning results

    CERN Document Server

    Shin, H J

    2001-01-01

    A scanning spectromicroscopy facility has been installed at the undulator radiation beamline at the Pohang Light Source. The spectromicroscopy is operational in both the scanning transmission X-ray microscopy (STXM) and the scanning photoelectron microscopy (SPEM) modes. Currently, the measured X-ray spot size on the sample is about 0.4 mu m. The effective photon energy range of the STXM is 250-1000 eV and that of the SPEM is 400-1000 eV. The performance of the facility is presented in this report.

  5. Supercontinuum optimization for dual-soliton based light sources using genetic algorithms in a Grid platform

    CERN Document Server

    Arteaga-Sierra, F R; Torres-Gómez, I; Torres-Cisneros, M; Moltó, G; Ferrando, A

    2014-01-01

    We present a numerical strategy to design fiber based dual pulse light sources exhibiting two predefined spectral peaks in the anomalous group velocity dispersion regime. The frequency conversion is based on the soliton fission and soliton self-frequency shift occurring during supercontinuum generation. The optimization process is carried out by a genetic algorithm that provides the optimum input pulse parameters: wavelength, temporal width and peak power. This algorithm is implemented in a Grid platform in order to take advantage of distributed computing. These results are useful for optical coherence tomography applications where bell-shaped pulses located in the second near-infrared window are needed.

  6. SUNY beamline facilities at the National Synchrotron Light Source (Final Report)

    Energy Technology Data Exchange (ETDEWEB)

    Coppens, Philip

    2003-06-22

    The DOE sponsored SUNY synchrotron project has involved close cooperation among faculty at several SUNY campuses. A large number of students and postdoctoral associates have participated in its operation which was centered at the X3 beamline of the National Synchrotron Light Source at Brookhaven National Laboratory. Four stations with capabilities for Small Angle Scattering, Single Crystal and Powder and Surface diffraction and EXAFS were designed and operated with capability to perform experiments at very low as well as elevated temperatures and under high vacuum. A large amount of cutting-edge science was performed at the facility, which in addition provided excellent training for students and postdoctoral scientists in the field.

  7. Long distance active hyperspectral sensing using high-power near-infrared supercontinuum light source.

    Science.gov (United States)

    Manninen, Albert; Kääriäinen, Teemu; Parviainen, Tomi; Buchter, Scott; Heiliö, Miika; Laurila, Toni

    2014-03-24

    A hyperspectral remote sensing instrument employing a novel near-infrared supercontinuum light source has been developed for active illumination and identification of targets. The supercontinuum is generated in a standard normal dispersion multi-mode fiber and has 16 W total optical output power covering 1000 nm to 2300 nm spectral range. A commercial 256-channel infrared spectrometer was used for broadband infrared detection. The feasibility of the presented hyperspectral measurement approach was investigated both indoors and in the field. Reflection spectra from several diffusive targets were successfully measured and a measurement range of 1.5 km was demonstrated.

  8. Lattice Design for PEP-X Ultimate Storage Ring Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Bane, K.L.F.; Cai, Y.; Nosochkov, Y.; Wang, M.-H.; /SLAC; Hettel, R.O.; /SLAC

    2011-12-13

    SLAC expertise in designing and operating high current storage rings and the availability of the 2.2-km PEP-II tunnel present an opportunity for building a next generation light source - PEP-X - that would replace the SPEAR3 storage ring in the future. The PEP-X 'baseline' design, with 164 pm-rad emittance at 4.5 GeV beam energy and a current of 1.5 A, was completed in 2010. As a next step, a so-called 'ultimate' PEP-X lattice, reducing the emittance to 11 pm-rad at zero current, has been designed. This emittance approaches the diffraction limited photon emittance for multi-keV photons, providing near maximum photon brightness and high coherence. It is achieved by using 7-bend achromat cells in the ring arcs and a 90-m damping wiggler in one of the 6 long straight sections. Details of the lattice design, dynamic aperture, and calculations of the intra-beam scattering effect and Touschek lifetime at a nominal 0.2 A current are presented. Accelerator-based light sources are in high demand for many experimental applications. The availability of the 2.2-km PEP-II tunnel at SLAC presents an opportunity for building a next generation light source - PEP-X - that would replace the existing SPEAR3 light source in the future. The PEP-X study started in 2008, and the 'baseline' design, yielding 164 pm-rad emittance at 4.5 GeV beam energy and a current of 1.5 A, was completed in 2010. This relatively conservative design can be built using existing technology. However, for a long term future, it is natural to investigate a more aggressive, so-called 'ultimate' ring design. The goal is to reduce the electron emittance in both x and y planes to near the diffraction limited photon emittance of 8 pm-rad at hard X-ray photon wavelength of 0.1 nm. This would provide a near maximum photon brightness and significant increase in photon coherence. This study was motivated by the advances in low emittance design at MAX-IV. The latter was used as a

  9. Low emittance pre-injection system for Iranian Light Source Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghipanah, A., E-mail: a.sadeghipanah@ipm.ir [Radiation Applications Department, Shahid Beheshti University, G. C., Tehran (Iran, Islamic Republic of); Feghhi, A.H. [Radiation Applications Department, Shahid Beheshti University, G. C., Tehran (Iran, Islamic Republic of); Rahighi, J. [Iranian Light Source Facility (ILSF), Institute for Research in Fundamental Sciences (IPM), Tehran (Iran, Islamic Republic of); Ghasem, H. [Iranian Light Source Facility (ILSF), Institute for Research in Fundamental Sciences (IPM), Tehran (Iran, Islamic Republic of); School of Particles and Accelerators, Institute for Research in Fundamental Sciences (IPM), Tehran (Iran, Islamic Republic of)

    2016-01-11

    In this paper, we introduce the Iranian Light Source Facility (ILSF) pre-injection system. The optimized parameters of its components, the related beam dynamics issues and the expected performance of the designed system have been described with detail. This paper explains fabrication procedures of some main components and gives the low power microwave measurement results of the constructed RF electron gun. The outcome bunches at the end of the ILSF pre-injection system will have the normalized emittance of 6 mm mrad, length of 1.55 ps and energy spread of 0.06%.

  10. Searching for biological traces on different materials using a forensic light source and infrared photography.

    Science.gov (United States)

    Sterzik, V; Panzer, S; Apfelbacher, M; Bohnert, M

    2016-05-01

    Because biological traces often play an important role in the investigation process of criminal acts, their detection is essential. As they are not always visible to the human eye, tools like a forensic light source or infrared photography can be used. The intention of the study presented was to give advice how to visualize biological traces best. Which wavelengths and/or filters give the best results for different traces on different fabrics of different colors? Therefore, blood (undiluted and diluted), semen, urine, saliva, and perspiration have been examined on 29 different materials.

  11. Short X-ray pulses from third-generation light sources.

    Science.gov (United States)

    Stepanov, A G; Hauri, C P

    2016-01-01

    High-brightness X-ray radiation produced by third-generation synchrotron light sources (TGLS) has been used for numerous time-resolved investigations in many different scientific fields. The typical time duration of X-ray pulses delivered by these large-scale machines is about 50-100 ps. A growing number of time-resolved studies would benefit from X-ray pulses with two or three orders of magnitude shorter duration. Here, techniques explored in the past for shorter X-ray pulse emission at TGLS are reviewed and the perspective towards the realisation of picosecond and sub-picosecond X-ray pulses are discussed.

  12. CDApps: integrated software for experimental planning and data processing at beamline B23, Diamond Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Hussain, Rohanah, E-mail: rohanah.hussain@diamond.ac.uk; Benning, Kristian; Javorfi, Tamas; Longo, Edoardo; Rudd, Timothy R.; Pulford, Bill; Siligardi, Giuliano, E-mail: rohanah.hussain@diamond.ac.uk [Diamond Light Source Ltd, Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2015-01-31

    CDApps software at Diamond B23 SRCD beamline is presented. The B23 Circular Dichroism beamline at Diamond Light Source has been operational since 2009 and has seen visits from more than 200 user groups, who have generated large amounts of data. Based on the experience of overseeing the users’ progress at B23, four key areas requiring the most assistance are identified: planning of experiments and note-keeping; designing titration experiments; processing and analysis of the collected data; and production of experimental reports. To streamline these processes an integrated software package has been developed and made available for the users. The subsequent article summarizes the main features of the software.

  13. Optical properties of organic-silicon photonic crystal nanoslot cavity light source

    Science.gov (United States)

    Yang, Ming-Jay; Lin, Chun-Chi; Wu, Yu-Shu; Wang, Likarn; Na, Neil

    2017-03-01

    We theoretically study a dielectric photonic crystal nanoslot cavity immersed in an organic fluid containing near-infrared dyes by means of a full rate equation model including the complete cavity QED effects. Based on the modeling results, we numerically design an organic-silicon cavity light source in which its mode volume, quality factor, and far-field emission pattern are optimized for energy-efficient, high-speed applications. Dye quantum efficiency improved by two orders of magnitude and 3dB modulation bandwidth of a few hundred GHz can be obtained.

  14. Development of at-wavelength metrology using grating-based shearing interferometry at Diamond Light Source

    Science.gov (United States)

    Wang, Hongchang; Berujon, Sebastien; Sawhney, Kawal

    2013-03-01

    The grating-based shearing interferometer has been established and further developed on B16 at Diamond Light Source. The beamline performances of both an X-ray plane mirror and a compound refractive lens (CRL) have been investigated using this technique. The slope error of the X-ray mirror was retrieved from the wavefront phase gradient, which was measured using two different processing schemes: phase stepping and moiré fringe analysis. The interferometer has demonstrated a high sensitivity with sub-microradian accuracy. Some of the advantages, disadvantages and limitations for the two approaches will also be presented.

  15. Experience with low-alpha lattices at the Diamond Light Source

    Science.gov (United States)

    Martin, I. P. S.; Rehm, G.; Thomas, C.; Bartolini, R.

    2011-04-01

    In this paper we present the experience at Diamond Light Source in the design, implementation, and operation of low momentum compaction factor lattices for the generation of short x-ray pulses and coherent THz radiation. The effects of higher-order terms in the expansion of the momentum compaction factor on beam dynamics are reviewed from a theoretical point of view, and the details of both high- and low-emittance solutions at Diamond are discussed. Measurements taken to characterize the lattices under a variety of machine conditions are presented, along with the practical limitations that exist as the momentum compaction factor is made to approach zero.

  16. CDApps: integrated software for experimental planning and data processing at beamline B23, Diamond Light Source.

    Science.gov (United States)

    Hussain, Rohanah; Benning, Kristian; Javorfi, Tamas; Longo, Edoardo; Rudd, Timothy R; Pulford, Bill; Siligardi, Giuliano

    2015-03-01

    The B23 Circular Dichroism beamline at Diamond Light Source has been operational since 2009 and has seen visits from more than 200 user groups, who have generated large amounts of data. Based on the experience of overseeing the users' progress at B23, four key areas requiring the most assistance are identified: planning of experiments and note-keeping; designing titration experiments; processing and analysis of the collected data; and production of experimental reports. To streamline these processes an integrated software package has been developed and made available for the users. The subsequent article summarizes the main features of the software.

  17. Microbunch Instability Observations from a THz Detector at Diamond Light Source

    Science.gov (United States)

    Shields, W.; Bartolini, R.; Boorman, G.; Karataev, P.; Lyapin, A.; Puntree, J.; Rehm, G.

    2012-05-01

    Diamond Light source is a third generation synchrotron facility dedicated to producing radiation of outstanding brightness, ranging from infra-red to x-rays. The short electron bunches that are accelerated around the storage ring are susceptible to the phenomenon of microbunching instabilities when the bunch charge exceeds a threshold. The primary feature of the microbunch instabilities is the onset of bursts of radiation in the THz range. The high frequencies involved in the emissions make detection and analysis challenging. A 60-90 GHz Schottky Barrier Diode detector was installed to investigate turn by turn evolution of the instabilities.

  18. Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

    OpenAIRE

    Zhu, Diling; Feng, Yiping; Stoupin, Stanislav; Terentyev, Sergey A.; Lemke, Henrik T.; Fritz, David M.; Chollet, Matthieu; Glownia, J. M.; Alonso-Mori, Roberto; Sikorski, Marcin; Song, Sanghoon; Brandt van Driel, Tim; Williams, Garth J; Messerschmidt, Marc; Boutet, Sébastien

    2014-01-01

    A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressure High-Temperature grown type-IIa diamond crystal plates with the (111) orientation. The first crystal has a thickness of ∼100 μm to allow high reflectivity within the Bragg bandwidth and good transm...

  19. Advanced Light Source Compendium of User Abstracts andTechnical Reports 1997

    Energy Technology Data Exchange (ETDEWEB)

    Cross, J.; Devereaux, M.K.; Dixon, D.J.; Greiner, A.; editors

    1998-07-01

    The Advanced Light Source (ALS), a national user facility located at Ernest Orlando Lawrence Berkeley National Laboratory of the University of California is available to researchers from academia, industry, and government laboratories. Operation of the ALS is funded by the Department of Energy's Office of Basic Energy Sciences. This Compendium contains abstracts written by users summarizing research completed or in progress during 1997, ALS technical reports describing ongoing efforts related to improvement in machine operations and research and development projects, and information on ALS beamlines planned through 1998.

  20. The Soft X-ray Research instrument at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Dakovski, Georgi L., E-mail: dakovski@slac.stanford.edu; Heimann, Philip; Holmes, Michael [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Krupin, Oleg [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); European XFEL, Notkestrasse 85, 22607 Hamburg (Germany); Minitti, Michael P.; Mitra, Ankush; Moeller, Stefan; Rowen, Michael; Schlotter, William F.; Turner, Joshua J. [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-02

    A description of the Soft X-ray Research instrument (SXR) at the Linac Coherent Light Source is given. Recent scientific highlights illustrate the wide variety of experiments and detectors that can be accommodated at SXR. The Soft X-ray Research instrument provides intense ultrashort X-ray pulses in the energy range 280–2000 eV. A diverse set of experimental stations may be installed to investigate a broad range of scientific topics such as ultrafast chemistry, highly correlated materials, magnetism, surface science, and matter under extreme conditions. A brief description of the main instrument components will be given, followed by some selected scientific highlights.