WorldWideScience

Sample records for lens system cesium

  1. Quaternary system of cesium halides

    International Nuclear Information System (INIS)

    Bukhalova, G.A.; Shegurova, G.A.; Yagub'yan, E.S.; Zaporozhets, E.G.

    1977-01-01

    The state diagram of the quaternary system consisting of fluorides, chlorides, bromides, and iodides of cesium has been studied by visual-polythermal, partially X-ray phase and thermographical analyses. The crystallization volume of the quaternary system involves the crystallization volume of cesium fluoride and the crystallization volume of the ternary solid solutions of the rest cesium halides. A quaternary nonvariant point corresponding to melting point 360 deg C appears on the crystallization surface which separates the cesium fluoride volume from the volume of the ternary solid solutions

  2. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  3. Novel matching lens and spherical ionizer for a cesium sputter ion ...

    Indian Academy of Sciences (India)

    Department of Nuclear Physics, Research School of Physical Sciences and Engineering,. Australian National University ... ionizer power and Cs reservoir temperature are shown. The three curves correspond to .... Cesium sputter ion source. One could gain the benefits of the higher C energy by just increasing the extractor.

  4. System of fluorides and chromates of cesium and lead

    International Nuclear Information System (INIS)

    Belyaev, I.N.; Revina, O.Ya.

    1980-01-01

    The triple mutual system of CsF-Cs 2 CrO 4 -PbF 2 -PbCrO 4 hav been investigated by the visual-polythermal and, in part, by the thermographical methods with a view to find out the nature of reactions occurring in recrystallization of cesium and lead fluorides and chromates from a melt. The parameters of six nonvariant points have been determined. The system may be classified as an irreversibly-mutual stable cross-section diagonal analysis [ru

  5. Corrected electrostatic lens systems for ion beams

    International Nuclear Information System (INIS)

    Dalgish, R.L.

    1981-01-01

    Recent work in our laboratory has introduced a new class of electrostatic focus forming element for beams, the ELCO lens. It compares favourably with the electrostatic and magnetic quadrupole elements conventionally used for microbeam formation. The ELCO lens does however have disadvantages associated with apertures and alignment. We have continued with the development of ion beam lenses and have evolved a further class of lens element which eliminates aperture and alignment problems. This new element can be combined like optical lenses into an aberration corrected system. Experimental measurement on the basic lens element has confirmed mathematical analysis of ion trajectories through the element. This mathematical analysis predicts that the basic element can be combined into a corrected lens system for, either: (1) high resolution microprobe formation with intrinsic rastering ability, the spot size limited only by the beam properties; or (2) high quality image formation with large magnification/demagnification ratio and wide angular aperture. (orig.)

  6. Modelling the transport of radioactive cesium released from the Fukushima Dai-ichi NPP with sediments through the hydrologic system

    Science.gov (United States)

    Kinouchi, T.; Omata, T.; Wei, L.; Liu, T.; Araya, M.

    2013-12-01

    Due to the accident of the Fukushima Dai-ichi Nuclear Power Plant on March 2011, a huge amount of radionuclides including Cesium-134 and Cesium-137 was deposited over the main island of Japan and the Pacific Ocean, resulting in further transfer and diffusion of Cesium through the atmospheric flow, watershed hydrological processes, and terrestrial ecosystem. Particularly, for the transfer of Cesium-134 and Cesium-137, sediments eroded and transported by the rainfall-runoff processes play an important role as Cesium tends to be strongly adsorbed to soil particles such as clay and silt. In this study, we focus on the transport of sediment and adsorbed Cesium in the watershed-scale hydrologic system to predict the long-term change of distribution of Cesium and its discharge to rivers and ocean. We coupled a physically-based distributed hydrological model with the modules of erosion and transport of sediments and adsorbed Cesium, and applied the coupled model to the Abukuma River watershed, which is located over the area of higher deposition of Cesium. In the model, complex land use and land cover distributions, and the effect of human activities such as irrigation, dam control and urban drainage system are taken into accounts. Simulation was conducted for the period of March 2011 until August 2012, with initial spatial distribution of Cesium-134 and Cesium-137 obtained by the airborne survey. Simulated flow rates and sediment concentrations agreed well with observed, and found that since the accident, two major storms in July and September 2011 transported about 50% of total sediments transported during the simulated periods. Cesium concentration in the sediment was reproduced well except for the difference in the initial periods. This difference is attributable to the uncertainty arisen from the initial distribution of Cesium in the soil and the transfer of Cesium from the forest canopy.

  7. Characterization of lens based photoacoustic imaging system

    Directory of Open Access Journals (Sweden)

    Kalloor Joseph Francis

    2017-12-01

    Full Text Available Some of the challenges in translating photoacoustic (PA imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF. Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  8. Solar powered desalination system using Fresnel lens

    Science.gov (United States)

    Sales, M. T. B. F.

    2016-11-01

    The Philippines is surrounded by coastal areas and these areas can be a potential source for potable water. This study aims to design and construct a solar powered desalination system using Fresnel lens. The experimental study was conducted using polluted salt water for the sample and desalination was carried out using the designed system. The desalination system was composed of the solar concentrator, solar still and the condenser system. The Fresnel lens was made of acrylic plastic and was an effective solar concentrator. Solar stills made of dark colored glass bottles were effective in absorbing the solar energy. The condenser system made of polybutylene and polystyrene were effective in condensing the vapor at ambient temperature. The shortest time of vaporization of the salt water was at 293 sec and the optimum angle of position of the lens was 36.42°. The amount of condensate collected was directly proportional to the amount of salt water in the solar still. The highest mean efficiency of the designed set-up was 34.82%. The water produced by the solar powered desalination system using Fresnel lens passed the standards set by WHO (World Health Organization) for drinking water.

  9. Alkali-iodide/urania systems at high temperatures. 1. Cesium uranate chemistry

    International Nuclear Information System (INIS)

    McFarlane, J.; LeBlanc, J.C.

    1994-09-01

    Uranate compounds are likely to form in irradiated fuel from the reaction between UO 2 and fission products along UO 2 grain boundaries and in the fuel-cladding gap. Literature on the high-temperature chemistry of cesium and rubidium uranates was reviewed. Results from Knudsen cell experiments from 900 to 2600 K on cesium uranates are discussed. These studies indicate that the uranate phases formed depend on the oxygen potential of the system, which varies with the composition of the condensed phase. 62 refs., 12 figs., 6 tabs., 2 appendices

  10. Selective removal of cesium ions from wastewater using copper hexacyanoferrate nanofilms in an electrochemical system

    International Nuclear Information System (INIS)

    Chen, Rongzhi; Tanaka, Hisashi; Kawamoto, Tohru; Asai, Miyuki; Fukushima, Chikako; Na, Haitao; Kurihara, Masato; Watanabe, Masayuki; Arisaka, Makoto; Nankawa, Takuya

    2013-01-01

    Highlights: ► Cu II HCF III film was developed for Cs removal in an electrochemical adsorption system (EAS). ► Hydrophilic coating was achieved by covering ferrocyanide ions on Cu II HCF III nanoparticles. ► Cs uptake and elution can be simply controlled by the EAS. ► EAS can selectively separate Cs in the presence of coexisting alkaline cations. ► Effective Cs removal can be adopted in a large pH range of 0.3–9.2. - Abstract: A novel electrochemical adsorption system using a nanoparticle film of copper (II) hexacyanoferrate (III) was proposed for selectively removing cesium from wastewater. This system can be used for cesium separation without extra chemical reagents or any filtration treatment. Cesium uptake and elution can be simply controlled by switching the applied potentials between anodes and cathodes. Data from batch kinetic studies well fitted the intraparticle diffusion equation, reflecting a two-step process: a steepest ascent portion followed by a plateau extending to the equilibrium. The effective cesium removal with a high distribution coefficient (K d > 5 × 10 5 mL/g) can be adopted in a large pH range from 0.3 to 9.2, and in the presence of several diverse coexisting alkaline cations, suggesting it can be taken as a promising technology for actual nuclear wastewater treatment.

  11. Magnetic system of the Tevatron electron lens

    International Nuclear Information System (INIS)

    Bogdanov, I.; Kozub, S.; Pleskach, V.; Sytnik, V.; Tkachenko, L.; Zintchenko, S.; Zubko, V.; Kuznetsov, G.; Sery, A.; Shiltsev, V.

    2000-01-01

    The Tevatron Electron Lens (TEL) system consisting of seven SC and four conventional magnets has been developed and fabricated in IHEP for increase of luminosity in Tevatron. The SC cable tension and preload of SC coils are calculated. The chosen cable design and cooling of the SC magnets ensure sufficient temperature margin for operating of SC magnets and their safety during quench. The system of conventional and SC solenoids create necessary trajectory of magnetic field lines for the TEL electron beam motion. SC dipoles and warm correctors permit to carry out correction of the electron beam motion [ru

  12. The effectiveness of soft contact lens disinfection systems against Acanthamoeba on the lens surface.

    Science.gov (United States)

    Liedel, K K; Begley, C G

    1996-03-01

    This investigation compared the efficacy of three widely used contact lens disinfection systems against an ocular isolate of Acanthamoeba polyphaga. Twenty-seven worn Ciba NewVues lenses were quartered, heat sterilized and inoculated with Acanthamoeba. Lens quarters were then randomly assigned to three experimental groups, with Group A lenses exposed to cleaner and saline rinse only, Group B to disinfection only, and Group C to both cleaner and disinfection. One quarter of each lens served as a control and the other three quarters were experimental. Quantification of viable Acanthamoeba remaining on the lens was performed after each step of the disinfection process. Group A lenses showed no significant difference between the treatments, or the treatments and the control. Group B lenses demonstrated a significant difference (p = 0.0001) between the treatments and the control. In Group C (cleaning and disinfection), the control lens quarters were significantly different (p = 0.037) from the experimental group, but there was no significant difference between the treatments. All three disinfection regimens were very effective in reducing the number of viable Acanthamoeba on the contact lens surface. In the absence of proper cleaning (Group B), AOSept was the most effective of the three. These results also show the importance of thoroughly rubbing the contact lens surface to decrease the number of Acanthamoeba.

  13. An expander system of high stable laser beam for cesium atomic fountain clocks

    Science.gov (United States)

    Chen, Jiang; Lin, Rui; Liu, Dandan; Zhang, Hui; Ruan, Jun; Shi, Junru; Yu, Fengxiang; Zhang, Shougang

    2017-10-01

    The quality of the cold atoms sample plays an important role to improve the performance of cesium atomic fountain clocks. The preparation of cold atoms sample has a strict requirement for cooling lasers characteristics such as power stability, polarization, collimation, uniformity and verticality. This work implements a design of an expander system of high stable laser beam for the cold atom preparation. The cooling laser characteristics can be adjusted by the design, and the use of non-magnetic materials to avoid the magnetic field on the impact of cold atom. The cold atom sample with the number of 2×108 and temperature of 5μk was obtained by expander system. The result meets the requirements of the preparation of cold atoms for cesium atomic fountain clocks.

  14. Cesium selenatoindiates

    International Nuclear Information System (INIS)

    Kadoshnikova, N.V.; Dejchman, Eh.N.; Tananaev, I.V.

    1977-01-01

    The system Cs 2 SeO 4 -In 2 (SeO 4 ) 3 -H 2 O has been studied by the isothermal solubility method at 20 deg C. Crystal optical analysis of CsIn(SeO 4 ) 2 x2H 2 O has been conducted. CsIn(SeO 4 ) 2 x12H 2 O has been synthesized at 0-+5 deg C. The individual structure of dihydrate and non-aqueous cesium selenateindiates has been confirmed by X-ray phase analysis

  15. Characterization of cesium uptake mediated by a potassium transport system of bacteria in a soil conditioner

    International Nuclear Information System (INIS)

    Zhang, Pengyao; Idota, Yoko; Yano, Kentaro; Negishi, Masayuki; Kawabata, Hideaki; Arakawa, Hiroshi; Ogihara, Takuo; Morimoto, Kaori; Tsuji, Akira

    2014-01-01

    We found that bacteria in a commercial soil conditioner sold in Ishinomaki, Miyagi, exhibited concentrative and saturable cesium ion (Cs + ) uptake in the natural range of pH and temperature. The concentration of intracellular Cs + could be condensed at least a few times higher compared with the outside medium of the cells. This uptake appeared to be mediated by a K + transport system, since Cs + uptake was dose-dependently inhibited by potassium ion (K + ). Eadie-Hofstee plot analysis indicated that the Cs + uptake involved a single saturable process. The maximum uptake amount (J max ) was the same in the presence and absence of K + , suggesting that Cs + and K + uptakes were competitive with respect to each other. These bacteria might be useful for bioremediation of cesium-contaminated soil. (author)

  16. Ternary system of cesium, rubidium and lead iodides

    International Nuclear Information System (INIS)

    Volchanskaya, V.V.; Dunaeva, T.I.; Il'yasov, I.I.

    1990-01-01

    Meltability diagram of ternary system (CsI) 2 -(RbI) 2 -PbI 2 has been studied. The liquidus of the given system consists of crystallization fields of solid solutions (CsI-RbI) and (CsI·PbI 2 -RbI-PbI 2 ), fields of incongruently melting compounds 9RbI·PbI 2 , 4CsI·PbI 2 and field of PbI 2 component. In the system two nonvariant points at 410 and 380 deg C are detected

  17. Effects of x-irradiation on lens reducing systems. [Rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Giblin, F.J.; Chakrapani, B.; Reddy, V.N.

    1978-01-01

    Studies have been made of the effects of x ray on various lens reducing systems including the levels of NADPH and glutathione (GSH), the activity of the hexose monophosphate shunt (HMS), and the activities of certain enzymes including glutathion reductase, glutathione peroxidase, and glucose-6-phosphate dehydrogenase (G-6-PD). It was found that during several weeks following x irradiation but prior to cataract formation there was very little change in the number of reduced -SH groups per unit weight of lens protein but that, with the appearance of cataract, there was a sudden loss of protein -SH groups. In contrast, the concentration of GSH in the x-rayed lens decreased throughout the experimental period. Similarly, the concentration of NADPH in the x-rayed lens was found to decrease significantly relative to controls one week prior to cataract formation and the ratio of NADPH to NADP/sup +/ in the lens shifted at this time period from a value greater than 1.0 in the control lens to less than 1.0 in the x-rayed lens. A corresponding decrease occurred in the activity of the HMS in x-rayed lenses as measured by culture in the presence of 1-/sup 14/C-labelled glucose. G-6-PD was partially inactivated in the x-rayed lens. Of the eight enzymes studied, G-6-PD appeared to be the most sensitive to x-irradiation. The data indicate that x-irradiation results in a steady decrease in the effectiveness of lens reducing systems and that, when these systems reach a critically low point, sudden oxidation of protein -SH groups and formation of high molecular weight protein aggregates may be initiated.

  18. Effects of x-irradiation on lens reducing systems

    International Nuclear Information System (INIS)

    Giblin, F.J.; Chakrapani, B.; Reddy, V.N.

    1978-01-01

    Studies have been made of the effects of x ray on various lens reducing systems including the levels of NADPH and glutathione (GSH), the activity of the hexose monophosphate shunt (HMS), and the activities of certain enzymes including glutathion reductase, glutathione peroxidase, and glucose-6-phosphate dehydrogenase (G-6-PD). It was found that during several weeks following x irradiation but prior to cataract formation there was very little change in the number of reduced -SH groups per unit weight of lens protein but that, with the appearance of cataract, there was a sudden loss of protein -SH groups. In contrast, the concentration of GSH in the x-rayed lens decreased throughout the experimental period. Similarly, the concentration of NADPH in the x-rayed lens was found to decrease significantly relative to controls one week prior to cataract formation and the ratio of NADPH to NADP + in the lens shifted at this time period from a value greater than 1.0 in the control lens to less than 1.0 in the x-rayed lens. A corresponding decrease occurred in the activity of the HMS in x-rayed lenses as measured by culture in the presence of 1- 14 C-labelled glucose. G-6-PD was partially inactivated in the x-rayed lens. Of the eight enzymes studied, G-6-PD appeared to be the most sensitive to x-irradiation. The data indicate that x-irradiation results in a steady decrease in the effectiveness of lens reducing systems and that, when these systems reach a critically low point, sudden oxidation of protein -SH groups and formation of high molecular weight protein aggregates may be initiated

  19. Adaptive neuro-fuzzy estimation of optimal lens system parameters

    Science.gov (United States)

    Petković, Dalibor; Pavlović, Nenad T.; Shamshirband, Shahaboddin; Mat Kiah, Miss Laiha; Badrul Anuar, Nor; Idna Idris, Mohd Yamani

    2014-04-01

    Due to the popularization of digital technology, the demand for high-quality digital products has become critical. The quantitative assessment of image quality is an important consideration in any type of imaging system. Therefore, developing a design that combines the requirements of good image quality is desirable. Lens system design represents a crucial factor for good image quality. Optimization procedure is the main part of the lens system design methodology. Lens system optimization is a complex non-linear optimization task, often with intricate physical constraints, for which there is no analytical solutions. Therefore lens system design provides ideal problems for intelligent optimization algorithms. There are many tools which can be used to measure optical performance. One very useful tool is the spot diagram. The spot diagram gives an indication of the image of a point object. In this paper, one optimization criterion for lens system, the spot size radius, is considered. This paper presents new lens optimization methods based on adaptive neuro-fuzzy inference strategy (ANFIS). This intelligent estimator is implemented using Matlab/Simulink and the performances are investigated.

  20. A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system

    Science.gov (United States)

    Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi

    2018-03-01

    This paper describes the design of a new probe forming lens system consisting of a high excitation magnetic quadrupole lens quadruplet that incorporates a single magnetic octupole lens. This system achieves both a high demagnification and a low spherical aberration compared to conventional high excitation systems and is intended for deployment for the Harbin 300 MeV proton microprobe for applications in space science and ion beam therapy. This relative simplicity of the ion optical design to include a single octupole lens minimizes the risks associated with the constructional and operational precision usually needed for the probe forming lens system and this system could also be deployed in microprobe systems that operate with less magnetically rigid ions. The design of the new system is validated with reference to two independent ion optical computer codes.

  1. 1600+434 - A NEW GRAVITATIONAL LENS SYSTEM

    NARCIS (Netherlands)

    JACKSON, N; DEBRUYN, AG; MYERS, S; BREMER, MN; MILEY, GK; SCHILIZZI, RT; BROWNE, IWA; NAIR, S; WILKINSON, PN; BLANDFORD, RD; PEARSON, TJ; READHEAD, ACS

    1995-01-01

    We report the discovery of a new gravitational lens system associated with the flat-spectrum radio source 1600+434. The system has been found in a new large survey of such radio sources. It consists of a 1.4-arcsec double radio source with an associated optical double at the same position and

  2. Innovative light collimator with afocal lens and total internal reflection lens for daylighting system.

    Science.gov (United States)

    Chen, Bo-Jian; Chen, Yin-Ti; Ullah, Irfan; Chou, Chun-Han; Chan, Kai-Cyuan; Lai, Yi-Lung; Lin, Chia-Ming; Chang, Cheng-Ming; Whang, Allen Jong-Woei

    2015-10-01

    This research presents a novel design of the collimator, which uses total internal reflection (TIR), convex, and concave lenses for the natural light illumination system (NLIS). The concept of the NLIS is to illuminate building interiors with natural light, which saves energy consumption. The TIR lens is used to collimate the light, and convex and concave lenses are used to converge the light to the required area. The results have shown that the efficiency in terms of achieving collimated light using the proposed collimator at the output of the light collector is better than that of a previous system without a collimator.

  3. Lens refracting cost effective photovoltaic solar energy concentrating systems

    International Nuclear Information System (INIS)

    Pilawjian, G.A.

    2014-01-01

    The overall cost reduction task is studied for photovoltaic (PV) solar energy systems. For that purpose, a new, cost effective lens refracting system is developed. The concentrating system consists of Fresnel lenses placed under different facet angles refracting the sun light onto the solar cells placed along a line. The developed photovoltaic concentrating system uses the mathematical model of Fresnel lens concentrating optics for photovoltaic systems used to optimize the system by cost. A computer program FLCPVSys2.1 for the new concentrating system is developed allowing to design a photovoltaic system of the required power with the minimum cost. The program can be used for designing a cost effective photovoltaic solar concentrating system

  4. Electrochemical assessment of water|ionic liquid biphasic systems towards cesium extraction from nuclear waste

    International Nuclear Information System (INIS)

    Stockmann, T. Jane; Zhang, Jing; Montgomery, Anne-Marie; Ding, Zhifeng

    2014-01-01

    Highlights: • Electroanalytical chemistry was employed to assess cesium ion extraction in biphasic systems. • Water|ionic liquid systems are much more efficient than traditional water|organic ones. • The metal ion to ligand stoichiometry and overall complexation constant were determined. • The stoichiometry was confirmed by mass spectrometry. • The ligand CMPO used in TRUEX processes was found to be effective for the FIT. - Abstract: A room temperature ionic liquid (IL) composed of a quaternary alkylphosphonium (trihexyltetradecylphosphonium, P 66614 + ) and tetrakis(pentafluorophenyl)borate anion (TB − ) was employed within a water|P 66614 TB (w|P 66614 TB or w|IL) biphasic system to evaluate cesium ion extraction in comparison to that with a traditional water|organic solvent (w|o) combination. 137 Cs is a major contributor to the radioactivity of spent nuclear fuel as it leaves the reactor, and its extraction efficiency is therefore of considerable importance. The extraction was facilitated by the ligand octyl(phenyl)-N,N′-diisobutylcarbamoylphosphine oxide (CMPO) used in TRans-Uranium EXtraction processes and investigated through well established liquid|liquid electrochemistry. This study gave access to the metal ion to ligand (1:n) stoichiometry and overall complexation constant, β, of the interfacial complexation reaction which were determined to be 1:3 and 1.6 × 10 11 at the w|P 66614 TB interface while the study at w|o elicited an n equal to 1 with β equal to 86.5. Through a straightforward relationship, these complexation constant values were converted to distribution coefficients, δ α , with the ligand concentrations studied for comparison to other studies present in the literature; the w|o and w|IL systems gave δ α of 2 and 8.2 × 10 7 , respectively, indicating a higher overall extraction efficiency for the latter. For the w|o system, the metal ion-ligand stoichiometries were confirmed through isotopic distribution analysis of mass

  5. Lens subluxation grading system: predictive value for ectopia lentis surgical outcomes

    OpenAIRE

    Mauro Waiswol; Niro Kasahara

    2009-01-01

    Objective: To present a classification system to grade ectopia lentis and to assess its usefulness as a predictor for surgical outcomes. Methods: Fifty-one eyes of 28 patients with either simple (19 patients) or Marfan syndrome-associated ectopia lentis (nine patients) with variable degrees of subluxation were operated on. Lens subluxation intensity was graded according to the lens subluxation grading system (LSGS) from grade 1 (lens on the whole pupillary area) up to grade 4 (lens absent fro...

  6. Creative optomechanical tolerancing in lens systems

    Science.gov (United States)

    Lee, Kim H.; Yoon, Youngshik; Maxwell, Jonathan

    1998-09-01

    The interface between optical design and fine-mechanical design is a creatively fertile stage in the design of an optical system. The optical designer learns `What the system is all about' and the fine-mechanical engineer is liberated creatively by finding out what the priorities are. On the other hand, optical tolerancing as a discipline, which is an attractive mix of optical physics at one end and hard-nosed mechanical pragmatism at the other, has a relatively fragmented literature. It is the purpose of this paper to (1) Point out some cultural contrasts between optical engineers, mechanical engineers and physicists in this context, (2) To present a new method of displaying the optical surface sensitivities so that one may identify datum surfaces in an intuitive way and (3) To summarize some useful formulae which provide a key to the mounting of optical components. Together these three aspects illustrate the scenery of this fertile terrain.

  7. Calculation of lens alignment errors using the ray transfer matrices for the lens assembly system with an autocollimator and a rotation stage

    Science.gov (United States)

    Chu, Jiyoung; Cho, Sungwhi; Joo, Won Don; Jang, Sangdon

    2017-08-01

    One of the most popular methods for high precision lens assembly of an optical system is using an autocollimator and a rotation stage. Some companies provide software for calculating the state of the lens along with their lens assembly systems, but the calculation algorithms used by the software are unknown. In this paper, we suggest a calculation method for lens alignment errors using ray transfer matrices. Alignment errors resulting from tilting and decentering of a lens element can be calculated from the tilts of the front and back surfaces of the lens. The tilt of each surface can be obtained from the position of the reticle image on the CCD camera of the autocollimator. Rays from a reticle of the autocollimator are reflected from the target surface of the lens, which rotates with the rotation stage, and are imaged on the CCD camera. To obtain a clear image, the distance between the autocollimator and the first lens surface should be adjusted according to the focusing lens of the autocollimator and the lens surfaces from the first to the target surface. Ray propagations for the autocollimator and the tilted lens surfaces can be expressed effectively by using ray transfer matrices and lens alignment errors can be derived from them. This method was compared with Zemax simulation for various lenses with spherical or flat surfaces and the error was less than a few percent.

  8. Highly sensitive straightness measurement system using a ball-lens

    International Nuclear Information System (INIS)

    Lee, Minho; Yang, Hyun-Ik; Cho, Nahm-Gyoo

    2016-01-01

    In this paper, a new and simple optical technique to accurately measure the straightness errors of a linear stage is proposed. To improve the performance, including the measurement sensitivity and resolution of the measurement system, and to simultaneously measure two-dimensional straightness errors (2D straightness errors), an optical system was designed using a laser, a retro-reflector, a ball-lens, and a two-dimensional position sensitive detector (2D PSD). The characteristics of the measurement system were analytically and experimentally investigated. A prototype measurement system was manufactured based on the investigated results, and the performances of this system have been tested. The measuring performance of the system was easily improved by about 12 times using the proposed technique and it can be further improved. It is shown that the proposed technique can easily and effectively improve the performance of a conventional straightness measurement system based on the geometric optical method using a PSD. (paper)

  9. Process for recovering cesium from cesium alum

    International Nuclear Information System (INIS)

    Mein, P.G.

    1984-01-01

    Cesium is recovered from cesium alum, CsAl(SO 4 ) 2 , by a two-reaction sequence in which the cesium alum is first dissolved in an aqueous hydroxide solution to form cesium alum hydroxide, CsAl(OH) 3 , and potassium sulfate, K 2 SO 4 . Part of the K 2 SO 4 precipitates and is separated from the supernatant solution. In the second reaction, a water-soluble permanganate, such as potassium permanganate, KMnO 4 , is added to the supernatant. This reaction forms a precipitate of cesium permanganate, CsMnO 4 . This precipitate may be separated from the residual solution to obtain cesium permanganate of high purity, which can be sold as a product or converted into other cesium compounds

  10. Chronic effects of cesium-137 ingestion on physiological systems in rat

    International Nuclear Information System (INIS)

    Voisin, Philippe; Grignard, Elise; Souidi, Maamar; Gueguen, Yann; Lestaevel, Philippe; Grandcolas, Line; Grison, Stephane; Dublineau, Isabelle; Gourmelon, Patrick

    2008-01-01

    Full text: The post-Chernobyl contamination by cesium-137 is of particular concern for public health. Several diseases have been reported in populations living in contaminated territories, such as behavior disorders, anxiety symptoms, cardiovascular diseases, perturbations of endocrine and reproductive status, immunity disturbances. The objective of this study was to determine in a rat model the effects of 137 Cs contamination by ingestion of post-accidental dose (6500 Bq/L) on several physiological systems, central nervous system, cardiovascular system, steroidogenesis, intestinal functions, and metabolism of cholesterol and of vitamin D. The animals were chronically and sub chronically contaminated via drinking water (∼150Bq per day). These experiments demonstrated that chronic ingestion of 137 Cs induced modifications of these physiological systems. A decrease in blood pressure was observed in contaminated animals. At the same time, changes in cardiac function were evidenced via increased plasma levels of CK and CK-MB and variations in gene expression of proteins involved in vascular tonus and of K + channels in cardiac left ventricle. Vitamin D metabolism was also modified by 137 Cs with a diminution of plasma level of Vitamin D (1,25(OH)D3), and changes in mRNA levels of cytochrome P450 CYP27B1 and CYP2R1 in brain and liver. Concerning cholesterol metabolism, no changes in plasma lipid levels were noted, although increased gene expression of liver X receptor α (LXRα), low-density lipoprotein receptor (LDLr) and apolipoprotein B (ApoB). In addition, steroidogenesis seemed to be modified, since decreased plasma level of 17β-estradiol and increased corticosterone plasma level were observed following chronic 137 Cs ingestion. These changes were associated with modification of mRNA levels of nuclear receptors in testis and of cytochrome P450 CYP11a1 in adrenal. Evaluation of intestine function demonstrated few effects of 137 Cs after chronic ingestion, except

  11. Cesium-137

    International Nuclear Information System (INIS)

    Ammerich, Marc; Frot, Patricia; Gambini, Denis-Jean; Gauron, Christine; Moureaux, Patrick; Herbelet, Gilbert; Lahaye, Thierry; Pihet, Pascal; Rannou, Alain

    2014-06-01

    This sheet belongs to a collection which relates to the use of radionuclides essentially in unsealed sources. Its goal is to gather on a single document the most relevant information as well as the best prevention practices to be implemented. These sheets are made for the persons in charge of radiation protection: users, radioprotection-skill persons, labor physicians. Each sheet treats of: 1 - the radio-physical and biological properties; 2 - the main uses; 3 - the dosimetric parameters; 4 - the measurement; 5 - the protection means; 6 - the areas delimitation and monitoring; 7 - the personnel classification, training and monitoring; 8 - the effluents and wastes; 9 - the authorization and declaration administrative procedures; 10 - the transport; and 11 - the right conduct to adopt in case of incident or accident. This sheet deals specifically with Cesium-137

  12. The NSLS-II Multilayer Laue Lens Deposition System

    International Nuclear Information System (INIS)

    Conley, R.; Bouet, N.; Biancarosa, J.; Shen, Q.; Boas, L.; Feraca, J.; Rosenbaum, L.

    2009-01-01

    The NSLS-II(1) program has a requirement for an unprecedented level of x-ray nanofocusing and has selected the wedged multilayer Laue lens(2,3) (MLL) as the optic of choice to meet this goal. In order to fabricate the MLL a deposition system is required that is capable of depositing depth-graded and laterally-graded multilayers with precise thickness control over many thousands of layers, with total film growth in one run up to 100 m thick or greater. This machine design expounds on the positive features of a rotary deposition system(4) constructed previously for MLLs and will contain multiple stationary, horizontally-oriented magnetron sources where a transport will move a substrate back and forth in a linear fashion over shaped apertures at well-defined velocities to affect a multilayer coating.

  13. A panoramic imaging system based on fish-eye lens

    Science.gov (United States)

    Wang, Ye; Hao, Chenyang

    2017-10-01

    Panoramic imaging has been closely watched as one of the major technologies of AR and VR. Mainstream panoramic imaging techniques lenses include fish-eye lenses, image splicing, and catadioptric imaging system. Meanwhile, fish-eyes are widely used in the big picture video surveillance. The advantage of fish-eye lenses is that they are easy to operate and cost less, but how to solve the image distortion of fish-eye lenses has always been a very important topic. In this paper, the image calibration algorithm of fish-eye lens is studied by comparing the method of interpolation, bilinear interpolation and double three interpolation, which are used to optimize the images.

  14. A New Optical System for Holographic Memory Applying a Finite Objective Lens

    Science.gov (United States)

    Yamakage, Yuzuru; Uno, Kazushi; Iwamura, Yasumasa; Shimokawa, Satoshi; Yoshikawa, Hiroyasu; Tezuka, Koichi; Ozaki, Kazuyuki

    2008-07-01

    We have developed a new objective lens for a holographic storage system to increase areal density. To balance focal length and working distance, we adopted a finite objective lens. By incorporating phase conjugate reproduction into the finite objective lens, we obtained practically applicable and adequate signal quality. We measured shift selectivity and the effect of crosstalk and evaluated book size, which was reduced by ca. 0.8. The areal density was estimated to increase by about 1.6 times when using the new objective lens.

  15. CLASS B2108+213 : a new wide-separation gravitational lens system

    NARCIS (Netherlands)

    McKean, JP; Browne, IWA; Jackson, NJ; Koopmans, LVE; Norbury, MA; Treu, T; York, TD; Biggs, AD; Blandford, RD; de Bruyn, AG; Fassnacht, CD; Mao, S; Myers, ST; Pearson, TJ; Phillips, PM; Readhead, ACS; Rusin, D; Wilkinson, PN

    2005-01-01

    We present observations of CLASS B2108 + 213, the widest separation gravitational lens system discovered by the Cosmic Lens All-Sky Survey. Radio imaging using the VLA at 8.46 GHz and MERLIN at 5 GHz shows two compact components separated by 4.56 arcsec with a faint third component in between which

  16. Class B0739+366 : A new two-image gravitational lens system

    NARCIS (Netherlands)

    Marlow, DR; Rusin, D; Norbury, M; Jackson, N; Browne, IWA; Wilkinson, PN; Fassnacht, CD; Myers, ST; Koopmans, LVE; Blandford, RD; Pearson, TJ; Readhead, ACS; de Bruyn, AG

    We present the discovery of CLASS B0739 + 366, a new gravitational lens system from the Cosmic Lens All-Sky Survey. Radio imaging of the source with the Very Large Array shows two compact components separated by with a flux density ratio of similar to6:1. High-resolution follow-up observations using

  17. Viewing Uganda's mental health system through a human rights lens.

    Science.gov (United States)

    Cooper, Sara; Ssebunnya, Joshua; Kigozi, Fred; Lund, Crick; Flisher, Alan

    2010-01-01

    There has been increased global concern about the human rights violations experienced by people with mental disorders. The aim of this study was to analyse Uganda's mental health care system through a human rights lens. A survey of the existing mental health system in Uganda was conducted using the WHO Assessment Instrument for Mental Health Systems. In addition, 62 interviews and six focus groups were conducted with a broad range of mental health stakeholders at the national and district levels. Despite possessing a draft mental health policy that is in line with many international human rights standards, Uganda's mental health system inadequately promotes and protects, and frequently violates the human rights of people with mental disorders. The mental health legislation is offensive and stigmatizing. It is common for people accessing mental health services to encounter physical and emotional abuse and an inadequate quality of care. Mental health services are inequitably distributed. Within Ugandan society, people with mental disorders also frequently experience widespread stigma and discrimination, and limited support. Promoting and protecting the rights of people with mental disorders has ethical and public health imperatives. A number of policy, legislative and service development initiatives are required.

  18. The Role of Chromohalobacter on Transport of Lanthanides and Cesium in the Dolomite Mineral System

    Energy Technology Data Exchange (ETDEWEB)

    Zengotita, Frances [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Emerson, Hilary Palmer [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dittrich, Timothy M. [Wayne State Univ., Detroit, MI (United States); Swanson, Juliet S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reed, Donald T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-01

    The chemical behavior of actinide series elements and fission products is a concern for the Waste Isolation Pilot Plant repository due to their uncertain mobility in the subsurface salt formation. In this work, we are observing the behavior of the halophilic bacterium, Chromohalobacter, and its effect on the mobility of lanthanides and cesium in the presence of dolomite. Batch and minicolumn experiments were conducted with Cs+ and lanthanides (Nd3+, Eu3+) to quantify potential transport with bacteria. Preliminary results show that Cs does not interact strongly with dolomite or Chromohalobacter, while the lanthanides can interact strongly with both minerals and bacteria depending on which the Ln contacts first.

  19. Lateral refraction and reflection of light polarized lenses principle. Coplanar lens systems

    International Nuclear Information System (INIS)

    Miranda, L.

    2012-01-01

    Studying the behavior of the linearly polarized light to impact a lens and in the lens itself, resulted in the discovery of a physical principle of optics, not mentioned or used so far. This phenomenon is very useful in practice. Perhaps the manifestation of the phenomenon occurs in the plane perpendicular to the road or optical axis, is due the reason that was not seen before, but it has always been there when polarized light passes through a lens. Known and mastered the principle has been manipulated for better research results, using for the first time a planar lens system, which according to the placement of the lens allows for accurate lags between the light beams ar the exits the system. (Author)

  20. A novel role for methyl cysteinate, a cysteine derivative, in cesium accumulation in Arabidopsis thaliana

    DEFF Research Database (Denmark)

    Adams, Eri; Miyazaki, Takae; Hayaishi-Satoh, Aya

    2017-01-01

    Phytoaccumulation is a technique to extract metals from soil utilising ability of plants. Cesium is a valuable metal while radioactive isotopes of cesium can be hazardous. In order to establish a more efficient phytoaccumulation system, small molecules which promote plants to accumulate cesium were...... investigated. Through chemical library screening, 14 chemicals were isolated as 'cesium accumulators' in Arabidopsis thaliana. Of those, methyl cysteinate, a derivative of cysteine, was found to function within the plant to accumulate externally supplemented cesium. Moreover, metabolite profiling demonstrated...

  1. Symmetrical optical imaging system with bionic variable-focus lens for off-axis aberration correction

    Science.gov (United States)

    Wang, Xuan-Yin; Du, Jia-Wei; Zhu, Shi-Qiang

    2017-09-01

    A bionic variable-focus lens with symmetrical layered structure was designed to mimic the crystalline lens. An optical imaging system based on this lens and with a symmetrical structure that mimics the human eye structure was proposed. The refractive index of the bionic variable-focus lens increases from outside to inside. The two PDMS lenses with a certain thickness were designed to improve the optical performance of the optical imaging system and minimise the gravity effect of liquid. The paper presents the overall structure of the optical imaging system and the detailed description of the bionic variable-focus lens. By pumping liquid in or out of the cavity, the surface curvatures of the rear PDMS lens were varied, resulting in a change in the focal length. The focal length range of the optical imaging system was 20.71-24.87 mm. The optical performance of the optical imaging system was evaluated by imaging experiments and analysed by ray tracing simulations. On the basis of test and simulation results, the optical performance of the system was quite satisfactory. Off-axis aberrations were well corrected, and the image quality was greatly improved.

  2. Optimization of a multilayer Laue lens system for a hard x-ray nanoprobe

    International Nuclear Information System (INIS)

    Jiang, Hui; Wang, Hua; Mao, Chengwen; Li, Aiguo; He, Yan; Dong, Zhaohui; Zheng, Yi

    2014-01-01

    Detailed designs of a multilayer Laue lens system for a hard x-ray nanoprobe, including flat and wedged types, are presented, to realize nanoscale point focus and high diffraction efficiency simultaneously. The difficulty of movement and alignment for lens, aperture and sample are considered in the optimization process. Considering the practical requirements of future experiments, the features of the beamline and the structural imperfections, the working energy range, the beam vibration and structural errors are estimated and discussed. (paper)

  3. Computerized method and system for designing an aerodynamic focusing lens stack

    Science.gov (United States)

    Gard, Eric [San Francisco, CA; Riot, Vincent [Oakland, CA; Coffee, Keith [Diablo Grande, CA; Woods, Bruce [Livermore, CA; Tobias, Herbert [Kensington, CA; Birch, Jim [Albany, CA; Weisgraber, Todd [Brentwood, CA

    2011-11-22

    A computerized method and system for designing an aerodynamic focusing lens stack, using input from a designer related to, for example, particle size range to be considered, characteristics of the gas to be flowed through the system, the upstream temperature and pressure at the top of a first focusing lens, the flow rate through the aerodynamic focusing lens stack equivalent at atmosphere pressure; and a Stokes number range. Based on the design parameters, the method and system determines the total number of focusing lenses and their respective orifice diameters required to focus the particle size range to be considered, by first calculating for the orifice diameter of the first focusing lens in the Stokes formula, and then using that value to determine, in iterative fashion, intermediate flow values which are themselves used to determine the orifice diameters of each succeeding focusing lens in the stack design, with the results being output to a designer. In addition, the Reynolds numbers associated with each focusing lens as well as exit nozzle size may also be determined to enhance the stack design.

  4. Single-stage quintuplet for upgrading triplet based lens system: Simulation for Atomki microprobe

    Science.gov (United States)

    Ponomarov, Artem; Rajta, Istvan; Nagy, Gyula; Romanenko, Oleksandr V.

    2017-08-01

    Among different configurations of lens systems for nuclear microprobes, the most common one is a triplet of magnetic quadrupole lenses. Nowadays, microanalysis and material modification will undoubtedly benefit from an improvement in spatial resolution. This work presents the results of simulations for improvement of the Oxford Triplet lens system at the Atomki microprobe with consideration of its system parameters and measured beam brightness distribution. For this purpose, an additional single-unit doublet of lenses with two power supplies was introduced. Using earlier developed methods, such a quintuplet system was optimized in order to determine the parameters which provided the highest resolution for different current operational modes with the same microprobe geometry. The tolerances for lens positioning accuracy were also calculated. The obtained quintuplet parameters indicate a resolution improvement for the Atomki microprobe compared to the Oxford Triplet system and these results validate further experimental testing of the proposed quintuplet.

  5. [Contact lens dynamometry influences the systemic blood circulation: clinical significance].

    Science.gov (United States)

    Rüfer, F; Köpke, B

    2014-11-01

    The diastolic and systolic pressure in the ophthalmic artery (OAPdia, OAPsys) as well as the venous pulsation pressure (VPP) can be determined by contact lens dynamometry (CLD). With these parameters, carotid artery stenosis, ocular perfusion, e.g., in glaucoma patients and the cerebrospinal pressure can be examined indirectly. In the underlying study comparative data were collected and it was investigated to what extent CLD itself leads to changes of the systemic blood pressure. In the course of a prospective trial CLD was performed in 162 eyes of 81 healthy volunteers (mean age 41.0 ± 17.3 years). VPP, OAPdia and OAPsys were measured. A mean was calculated from 5 single readings. Directly before and after CLD automated blood pressure measurements according to Riva-Rocci (RR) and the heart rate were obtained in both arms. In the entire group, the mean VPP was 21 ± 9 mmHg on the right side and 19 ± 8 mmHg on the left side. The mean OAPdia was 60 ± 14 mmHg on the right and 67 ± 14 mmHg on the left side. The mean OAPsys was 91 ± 17 and 101 ± 21 mmHg, respectively. The mean variation coefficient from 5 single readings was 13/16 % for VPP (right/left), 7.4/8.2 % for OAPdia and 6.2/6.2 % for OAPsys. The difference between right and left eyes concerning OAPdia and OAPsys was statistically significant (Wilcoxon test; p < 0.001). VPP and OAPsys were not correlated with age, OAPdia showed a weak correlation with age on the right side (Spearman R = 0.23; p = 0.03). Blood pressure (RR) dropped from a mean 137/84 to 135/82 mmHg in the right arm and from 135/84 to 132/83 mmHg in the left arm. The change of the diastolic values of the right side and of the systolic values of the left side reached statistical significance (p < 0.05). The difference of the systolic blood pressure and the heart rate before and after CLD were weakly correlated (Spearman R = - 0.28; p = 0.01). The extent of the systemic

  6. Construction of a 300-keV compact ion microbeam system with a three-stage acceleration lens

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Yasuyuki, E-mail: ishii.yasuyuki@jaea.go.jp; Ohkubo, Takeru; Kojima, Takuji; Kamiya, Tomihiro

    2014-08-01

    Hydrogen ion microbeams were experimentally formed at beam energies below 150 keV using a 300-keV compact microbeam system that was constructed at the Japan Atomic Energy Agency. This paper is a preliminary report on the performance of the three-stage acceleration lens used in the compact microbeam system. This system consists of a three-stage acceleration lens and a plasma-type ion source. Since the three-stage acceleration lens was designed to simultaneously accelerate and focus the ion beam, the compact microbeam system is only about 1-m high and can be placed in a small experimental room. To evaluate the effectiveness of the three-stage acceleration lens, experimentally measured beam sizes are compared with theoretically calculated ones. The calculated and measured beam sizes were consistent within 10%. This shows that the three-stage acceleration lens is effective as a focusing lens for forming microbeams.

  7. Systemic arterial hypertension in patients exposed to Cesium-137 in Goiânia-GO: prevalence study

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, José Victor Rabelo; Pinto, Murillo Macêdo; Figueredo, Roberto Miller Pires; Lima, Helen de; Sacchetim, Sylvana de Castro, E-mail: murillo_bb@hotmail.com [Centro Universitário de Anápolis (UniEVANGÉLICA), Goiania, GO (Brazil); Souto, Rafael [Secretaria da Saúde do Estado de Goiás, GO (Brazil)

    2017-06-15

    Background: Systemic Arterial Hypertension (SAH) in the Brazilian population, in populations not exposed to Césium-137, presents a prevalence of 28% nationwide. However, in the group of radioactivity victims, these values are unknown. Objective: To analyze the prevalence of hypertension in patients exposed to Cesium-137 in Goiânia, enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) (Radioactivity Victims Monitoring System) of the Centro de Assistência aos Radioacidentados (C.A.R.A) (Assistance Center for Radioactivity Victims). Methods: This is a descriptive, observational cross-sectional epidemiological study carried out in Goiânia-Goiás, from August 2013 to October 2014, with a group of patients enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) of the Centro de Assistência a Radioacidentados (C.A.R.A.). A total of 102 radioactive patients were divided into two groups: group 1 with 40 and group 2 with 62 participants. A field survey was conducted with a closed and semi-structured questionnaire in which the following contexts were addressed: sociodemographic profile, life habits and personal background. A database was created using the Google Forms application from the Google Web technologies company. The duly collected and stored data were imported and analyzed in the statistical software SPSS, version 21. Results: The prevalence of SAH reached a total of 25% (12 individuals) of the 48 interviewees, 50% of women (24) and 50% of men (24), of which 22.9% (11) of the radioactivity victims revealed to be smokers. Conclusion: The prevalence of SAH in the radioactivity victims population is similar to that of the population in general. (author)

  8. Systemic arterial hypertension in patients exposed to Cesium-137 in Goiânia-GO: prevalence study

    International Nuclear Information System (INIS)

    Rodrigues, José Victor Rabelo; Pinto, Murillo Macêdo; Figueredo, Roberto Miller Pires; Lima, Helen de; Sacchetim, Sylvana de Castro; Souto, Rafael

    2017-01-01

    Background: Systemic Arterial Hypertension (SAH) in the Brazilian population, in populations not exposed to Césium-137, presents a prevalence of 28% nationwide. However, in the group of radioactivity victims, these values are unknown. Objective: To analyze the prevalence of hypertension in patients exposed to Cesium-137 in Goiânia, enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) (Radioactivity Victims Monitoring System) of the Centro de Assistência aos Radioacidentados (C.A.R.A) (Assistance Center for Radioactivity Victims). Methods: This is a descriptive, observational cross-sectional epidemiological study carried out in Goiânia-Goiás, from August 2013 to October 2014, with a group of patients enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) of the Centro de Assistência a Radioacidentados (C.A.R.A.). A total of 102 radioactive patients were divided into two groups: group 1 with 40 and group 2 with 62 participants. A field survey was conducted with a closed and semi-structured questionnaire in which the following contexts were addressed: sociodemographic profile, life habits and personal background. A database was created using the Google Forms application from the Google Web technologies company. The duly collected and stored data were imported and analyzed in the statistical software SPSS, version 21. Results: The prevalence of SAH reached a total of 25% (12 individuals) of the 48 interviewees, 50% of women (24) and 50% of men (24), of which 22.9% (11) of the radioactivity victims revealed to be smokers. Conclusion: The prevalence of SAH in the radioactivity victims population is similar to that of the population in general. (author)

  9. Millimeter Wave Imaging System Using Monopole Antenna with Cylindrical Reflector and Silicon Lens

    Science.gov (United States)

    Mizuno, Maya; Fukunaga, Kaori; Suzuki, Masaki; Saito, Shingo; Fujii, Katsumi; Hosako, Iwao; Yamanaka, Yukio

    2011-04-01

    We built a reflection imaging system that uses a monopole antenna with a cylindrical reflector and silicon semi-spherical lens for millimeter waves to identify detachments of alabaster from support material such as wood and stone, which can be subject to painting deterioration. Based on the electric field property near the monopole antenna in the system and the lens effect, the system was able to clearly image a test sample made of 2-mm width aluminium tape, which was placed within a range of approximately 10 mm from the lens. In practical imaging testing using a detachment model, which consists of alabaster and wood plating, the result also showed the possibility of observing slight detachment of the alabaster from the wood more easily than an imaging with large numerical aperture.

  10. Fast Tomography Imaging System for Material Surface Based on Doublet-cylinder-lens in Intelligent OCT

    Directory of Open Access Journals (Sweden)

    Xu Shijun

    2017-01-01

    Full Text Available A fast lateral line-scan mode in OCT was investigated. The elimination of spherical aberration, the beam mode and the focus of doublet-cylinder-lens, were theoretically analyzed. The parameters and signal characteristics of the confocus microscopy system with doublet-cylinder-lens were analyzed and simulated. The relation between the transverse resolution and the numerical aperture and the depth of focus (DOF was discussed in the OCT. Our results show that the spherical aberration and the sine aberration are effectively eliminated in the doublet-cylinder-lens with K9-ZF2 glass. The beam is uniformly focused on the arc-sagitta-plane of cylinder lens, and the parallel interference pattern with axial symmetry is in favor of improving transverse resolution. The transverse resolution depends upon the numerical aperture and the DOF. The scanning velocity of doublet-cylinder-lens confocus microscopy system is 103 times faster than the traditional spot-scan, while the transverse resolution is 15μm and the constraints of aperture 50.8 mm. This advanced system will be valuable in real-time imaging to material surface.

  11. Surface interactions of cesium and boric acid with stainless steel

    International Nuclear Information System (INIS)

    Grossman-Canfield, N.

    1995-08-01

    In this report, the effects of cesium hydroxide and boric acid on oxidized stainless steel surfaces at high temperatures and near one atmosphere of pressure are investigated. This is the first experimental investigation of this chemical system. The experimental investigations were performed using a mass spectrometer and a mass electrobalance. Surfaces from the different experiments were examined using a scanning electron microscope to identify the presence of deposited species, and electron spectroscopy for chemical analysis to identify the species deposited on the surface. A better understanding of the equilibrium thermodynamics, the kinetics of the steam-accelerated volatilizations, and the release kinetics are gained by these experiments. The release rate is characterized by bulk vaporization/gas-phase mass transfer data. The analysis couples vaporization, deposition, and desorption of the compounds formed by cesium hydroxide and boric acid under conditions similar to what is expected during certain nuclear reactor accidents. This study shows that cesium deposits on an oxidized stainless steel surface at temperatures between 1000 and 1200 Kelvin. Cesium also deposits on stainless steel surfaces coated with boric oxide in the same temperature ranges. The mechanism for cesium deposition onto the oxide layer was found to involve the chemical reaction between cesium and chromate. Some revaporization in the cesium hydroxide-boric acid system was observed. It has been found that under the conditions given, boric acid will react with cesium hydroxide to form cesium metaborate. A model is proposed for this chemical reaction

  12. A new quadruple gravitational lens system : CLASS B0128+437

    NARCIS (Netherlands)

    Phillips, PM; Norbury, MA; Koopmans, LVE; Browne, IWA; Jackson, NJ; Wilkinson, PN; Biggs, AD; Blandford, RD; de Bruyn, AG; Fassnacht, CD; Helbig, P; Mao, S; Marlow, DR; Myers, ST; Pearson, TJ; Readhead, ACS; Rusin, D; Xanthopoulos, E

    2000-01-01

    High-resolution MERLIN observations of a newly discovered four-image gravitational lens system, B0128+437, are presented. The system was found after a careful re-analysis of the entire CLASS data set. The MERLIN observations resolve four components in a characteristic quadruple-image configuration;

  13. Electrically switched cesium ion exchange

    International Nuclear Information System (INIS)

    Lilga, M.A.; Orth, R.J.; Sukamto, J.P.H.; Schwartz, D.T.; Haight, S.M.; Genders, J.D.

    1997-04-01

    Electrically Switched Ion Exchange (ESIX) is a separation technology being developed as an alternative to conventional ion exchange for removing radionuclides from high-level waste. The ESIX technology, which combines ion exchange and electrochemistry, is geared toward producing electroactive films that are highly selective, regenerable, and long lasting. During the process, ion uptake and elution are controlled directly by modulating the potential of an ion exchange film that has been electrochemically deposited onto a high surface area electrode. This method adds little sodium to the waste stream and minimizes the secondary wastes associated with traditional ion exchange techniques. Development of the ESIX process is well underway for cesium removal using ferrocyanides as the electroactive films. Films having selectivity for perrhenate (a pertechnetate surrogate) over nitrate also have been deposited and tested. A case study for the KE Basin on the Hanford Site was conducted based on the results of the development testing. Engineering design baseline parameters for film deposition, film regeneration, cesium loading, and cesium elution were used for developing a conceptual system. Order of magnitude cost estimates were developed to compare with conventional ion exchange. This case study demonstrated that KE Basin wastewater could be processed continuously with minimal secondary waste and reduced associated disposal costs, as well as lower capital and labor expenditures

  14. Radioactive source control and electronics for the ATLAS tile calorimeter cesium calibration system

    CERN Document Server

    Shalanda, N A; Kopikov, S; Shalimov, A; Soldatov, M; Solodkov, A; Starchenko, E A

    2003-01-01

    A system using a radioactive /sup 137/Cs source to calibrate and monitor the Hadron Calorimeter (TileCal) of the ATLAS experiment at the LHC is described. The system includes a set of sensors to monitor the position of the source which moves via hydraulic propulsion. The design of the sensors, the corresponding electronic modules and their performance are detailed. (6 refs).

  15. Lens subluxation grading system: predictive value for ectopia lentis surgical outcomes

    Directory of Open Access Journals (Sweden)

    Mauro Waiswol

    2009-03-01

    Full Text Available Objective: To present a classification system to grade ectopia lentis and to assess its usefulness as a predictor for surgical outcomes. Methods: Fifty-one eyes of 28 patients with either simple (19 patients or Marfan syndrome-associated ectopia lentis (nine patients with variable degrees of subluxation were operated on. Lens subluxation intensity was graded according to the lens subluxation grading system (LSGS from grade 1 (lens on the whole pupillary area up to grade 4 (lens absent from the pupillary area. Thirty eyes underwent cataract extraction (“dry” aspiration with endocapsular ring and in-the-bag intraocular lens (IOL implantation. Twenty-one eyes underwent cataract extraction (“dry” aspiration with scleral fixation of the IOL. The predictive value of the LSGS was assessed by analyzing the post-operative outcomes, including visual acuity (VA, endothelial cell loss, and complications for each grade on the grading system. Rresults: Patients were classified into grade 1 (19.6%, grade 2 (51% and grade 3 (29.4%. Post-operative VA was lower for eyes with larger degrees of subluxation. The higher the subluxation grade, the higher the endothelial cell loss, as well as, the frequency of vitreous loss and surgical time. Higher subluxation grades prevented optimal surgical outcomes with endocapsular ring and in-the-bag IOL implantation. Cconclusions: The LSGS provides an estimate of the surgical success of ectopia lentis. Adequate standardization of lens subluxation is crucial for understanding studies dealing with the surgical correction of this disorder.

  16. Single-lens 3D digital image correlation system based on a bilateral telecentric lens and a bi-prism: validation and application.

    Science.gov (United States)

    Wu, Lifu; Zhu, Jianguo; Xie, Huimin

    2015-09-10

    By using the principle of stereovision, 3D digital image correlation (3D-DIC) can determine the 3D morphology and deformation of a target and has been widely used in experimental mechanics as a noncontact 3D measurement technique. To eliminate the limitations of the conventional 3D-DIC system, this study proposes a calibration-free single-lens 3D-DIC system based on a bilateral telecentric lens and a bi-prism. The performance of the proposed system is verified by tests of rigid-body translation along the out-of-plane direction. As a comparison, the same rigid-body translations are measured using a single-entocentric-lens 3D-DIC system. The results show that the measurement accuracy of the proposed system is higher than that of the entocentric-lens-based one. As an application, the proposed system is used to measure the thermal linear expansion of a ceramic plate at elevated temperatures. The reasonable measurement results verify its applicability in deformation measurements, even in high-temperature environments.

  17. Colloid-Facilitated Cesium Transport in the Vadose Zone at the Hanford Site

    Science.gov (United States)

    Chen, G.; Flury, M.; Harsh, J. B.

    2002-12-01

    Transport of 137Cs and colloids through a Hanford sediment column under unsaturated conditions was investigated. The movement of cesium and colloids followed the convective-dispersive solute transport equation and the mass transfer processes governing colloid-facilitated cesium transport were colloidal deposition, cesium sorption to the medium, and cesium sorption to colloids. It was found that cesium was strongly adsorbed to Hanford sediments and only colloid-bound cesium could breakthrough. Cesium experienced a greater facilitated transport at higher saturation than at low saturation and the migration of cesium was more a function of the behavior of colloids than of dissolved cesium. A two-region model was used in describing colloid-facilitated cesium migration and the influence of the system saturation was examined by relating to the variation of simulated model parameters. Hanford native colloids, i.e., \\textit{in-situ} colloids from the Hanford site, and modified colloids, i.e., \\textit{in-situ} colloids subject to chemical treatment, were used as model colloids to study facilitated cesium transport in this research. The results of this study will be of help in understanding the response of colloid-facilitated cesium migration to variation of saturation at the Hanford site. Key words: cesium; colloid; facilitated transport; saturation; and Hanford sediment.

  18. Student Satisfaction with Learning Management Systems: A Lens of Critical Success Factors

    Science.gov (United States)

    Naveh, Gali; Tubin, Dorit; Pliskin, Nava

    2012-01-01

    Institutions of higher education have invested heavily in learning management systems (LMS) for creating course websites. Yet, how to assess LMS effectiveness is not fully agreed upon. Based on institutional theory, this article considers student satisfaction as indicative of LMS success and proposes a lens of critical success factors (CSF) as a…

  19. Biaxial-Type Concentrated Solar Tracking System with a Fresnel Lens for Solar-Thermal Applications

    OpenAIRE

    Tsung Chieh Cheng; Chao Kai Yang; I Lin

    2016-01-01

    In this paper, an electromechanical, biaxial-type concentrated solar tracking system was designed for solar-thermal applications. In our tracking system, the sunlight was concentrated by the microstructure of Fresnel lens to the heating head of the Stirling engine and two solar cells were installed to provide the power for tracking system operation. In order to obtain the maximum sun power, the tracking system traces the sun with the altitude-azimuth biaxial tracing method and accurately main...

  20. Effects of chronic cesium-137 ingestion on physiological system in rat

    International Nuclear Information System (INIS)

    Voisin, Philippe; Grignard, Elise; Souidi, Maamar; Gueguen, Yann; Lestaevel, Philippe; Grandcolas, Line; Grison, Stephane; Dublineau, Isabelle; Gourmelon, Patrick

    2008-01-01

    Full text: Several diseases have been reported in populations living in contaminated territories in the vicinity of Chernobyl, such as behavior disorders, anxiety symptoms, cardiovascular diseases, perturbations of endocrine and reproductive status, immunity disturbances. Therefore, the post-Chernobyl contamination by 137 Cs is of particular concern for public health. The objective of this study was to determine in a rat model the effects of 137 Cs contamination by ingestion of 6500 Bq/L on several physiological systems, central nervous system, cardiovascular system, steroidogenesis, intestinal functions, metabolism of cholesterol and of vitamin D. The animals were chronically and sub-chronically contaminated via drinking water (∼150 Bq per day) at a post-accidental dose level. Our experiments demonstrated that chronic ingestion of 137 Cs induced some disturbances of these systems. A decrease in blood pressure was observed in contaminated animals. At the same time, changes in cardiac function were evidenced via increased plasma levels of CK and CK-MB and variations in gene expression of proteins involved in vascular tonus (Gueguen et al. Toxicol Lett 2007), and of K + channels in cardiac left ventricle. Vitamin D metabolism was also modified by 137 Cs with a diminution of plasma level of Vitamin D (1,25(OH)D3), and changes in mRNA levels of cytochrome P450 CYP27B1 and CYP2R1 in brain and liver (Tissandie et al. Toxicology 2006). Concerning cholesterol metabolism, no changes in plasma lipid levels were noted, although increased gene expression of liver X receptor α (LXRα), low-density lipoprotein receptor (LDLr) and apolipoprotein B (ApoB) (Souidi et al. Int J Toxicol 2006). In addition, steroidogenesis seemed to be modified, since decreased plasma level of 17β-estradiol and increased corticosterone plasma level were observed following chronic 137 Cs ingestion. These changes were associated with modification of mRNA levels of nuclear receptors in testis and of

  1. The use of contact lens telescopic systems in low vision rehabilitation.

    Science.gov (United States)

    Vincent, Stephen J

    2017-06-01

    Refracting telescopes are afocal compound optical systems consisting of two lenses that produce an apparent magnification of the retinal image. They are routinely used in visual rehabilitation in the form of monocular or binocular hand held low vision aids, and head or spectacle-mounted devices to improve distance visual acuity, and with slight modifications, to enhance acuity for near and intermediate tasks. Since the advent of ground glass haptic lenses in the 1930's, contact lenses have been employed as a useful refracting element of telescopic systems; primarily as a mobile ocular lens (the eyepiece), that moves with the eye. Telescopes which incorporate a contact lens eyepiece significantly improve the weight, comesis, and field of view compared to traditional spectacle-mounted telescopes, in addition to potential related psycho-social benefits. This review summarises the underlying optics and use of contact lenses to provide telescopic magnification from the era of Descartes, to Dallos, and the present day. The limitations and clinical challenges associated with such devices are discussed, along with the potential future use of reflecting telescopes incorporated within scleral lenses and tactile contact lens systems in low vision rehabilitation. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Erosion and deposition in a field/forest system estimated using cesium-137 activity

    International Nuclear Information System (INIS)

    Lowrance, R.; McIntyre, S.; Lance, C.

    1988-01-01

    Soil erosion and deposition were estimated using Cs-137 activity within a 7.25-ha field/forest system in the southeastern coastal plain. Sol eroded from the field was deposited both in the riparian forest ecosystem and in downslope areas of the field. Total activity, depth to peak activity, and depth to zero activity increased downslope from field to stream. Erosion and deposition rates, estimated by changes in activity per unit area from a reference undisturbed forest site, showed that about twice as much total deposition had taken place as total erosion. Excess deposition was attributed to deposition from the upstream portions of the watershed. Erosion and deposition rates estimated with this method were about 63 and 256 Mg/ha/yr, respectively. Erosion and deposition rates estimated by two different calculation techniques were nearly identical. These rates were considerably higher than rates estimated in an earlier study. The rates may be overestimated because the differential rates of Cs-137 movement on clay particles were not considered. The riparian ecosystem acted as a very efficient sediment trap. 19 refs., 5 figs., 3 tabs

  3. Design study for a 16x zoom lens system for visible surveillance camera

    Science.gov (United States)

    Vella, Anthony; Li, Heng; Zhao, Yang; Trumper, Isaac; Gandara-Montano, Gustavo A.; Xu, Di; Nikolov, Daniel K.; Chen, Changchen; Brown, Nicolas S.; Guevara-Torres, Andres; Jung, Hae Won; Reimers, Jacob; Bentley, Julie

    2015-09-01

    *avella@ur.rochester.edu Design study for a 16x zoom lens system for visible surveillance camera Anthony Vella*, Heng Li, Yang Zhao, Isaac Trumper, Gustavo A. Gandara-Montano, Di Xu, Daniel K. Nikolov, Changchen Chen, Nicolas S. Brown, Andres Guevara-Torres, Hae Won Jung, Jacob Reimers, Julie Bentley The Institute of Optics, University of Rochester, Wilmot Building, 275 Hutchison Rd, Rochester, NY, USA 14627-0186 ABSTRACT High zoom ratio zoom lenses have extensive applications in broadcasting, cinema, and surveillance. Here, we present a design study on a 16x zoom lens with 4 groups (including two internal moving groups), designed for, but not limited to, a visible spectrum surveillance camera. Fifteen different solutions were discovered with nearly diffraction limited performance, using PNPX or PNNP design forms with the stop located in either the third or fourth group. Some interesting patterns and trends in the summarized results include the following: (a) in designs with such a large zoom ratio, the potential of locating the aperture stop in the front half of the system is limited, with ray height variations through zoom necessitating a very large lens diameter; (b) in many cases, the lens zoom motion has significant freedom to vary due to near zero total power in the middle two groups; and (c) we discuss the trade-offs between zoom configuration, stop location, packaging factors, and zoom group aberration sensitivity.

  4. Decorporation of cesium-137

    International Nuclear Information System (INIS)

    Le Fleche, Ph.; Destombe, C.; Grasseau, A.; Mathieu, J.; Chancerelle, Y.; Mestries, J.C.

    1997-01-01

    Cesium radio-isotopes, especially cesium-137 ( 137 Cs) are among the radionuclides of main importance produced by a fission reaction in reactor or a nuclear weapon explosion. In the environment, 137 Cs is a major contaminant which can cause severe β, γirradiations and contaminations. 137 Cs is distributed widely and relatively uniformly throughout the body with the highest concentration in skeletal muscles. A treatment becomes difficult afterwards. The purposes of this report are Firstly to compare the Prussian blue verses cobalt and potassium ferrocyanide (D.I. blue) efficiency for the 137 Cs decorporation and secondly to assess a chronological treatment with D.I. blue. (author)

  5. GOLDEN GRAVITATIONAL LENSING SYSTEMS FROM THE SLOAN LENS ACS SURVEY. I. SDSS J1538+5817: ONE LENS FOR TWO SOURCES ,

    International Nuclear Information System (INIS)

    Grillo, C.; Seitz, S.; Bender, R.; Eichner, T.; Bauer, A.; Lombardi, M.; Gobat, R.

    2010-01-01

    We present a gravitational lensing and photometric study of the exceptional strong lensing system SDSS J1538+5817, identified by the Sloan Lens Advanced Camera for Survey. The lens is a luminous elliptical galaxy at redshift z l = 0.143. Using Hubble Space Telescope public images obtained with two different filters, the presence of two background sources lensed, respectively, into an Einstein ring and a double system is ascertained. Our new spectroscopic observations, performed at the Nordic Optical Telescope, reveal unequivocally that the two sources are located at the same redshift z s = 0.531. We investigate the total (luminous and dark) mass distribution of the lens between 1 and 4 kpc from the galaxy center by means of parametric and non-parametric lensing codes that describe the multiple images as point-like objects. Bootstrapping and Bayesian analyses are performed to determine the uncertainties on the quantities relevant to the lens mass characterization. Several disparate lensing models provide results that are consistent, given the errors, with those obtained from the best-fit model of the lens mass distribution in terms of a singular power-law ellipsoid model. In particular, the lensing models agree on: (1) reproducing accurately the observed positions of the images; (2) predicting a nearly axisymmetric total mass distribution, centered and oriented as the light distribution; (3) measuring a value of 8.11 +0.27 -0.59 x 10 10 M sun for the total mass projected within the Einstein radius of 2.5 kpc; and (4) estimating a total mass density profile slightly steeper than an isothermal one (ρ(r)∝r -2.33 +0.43 -0.20 ). A fit of the Sloan Digital Sky Survey multicolor photometry with composite stellar population models provides a value of 20 +1 -4 x 10 10 M sun for the total mass of the galaxy in the form of stars and of 0.9 +0.1 -0.2 for the fraction of projected luminous over total mass enclosed inside the Einstein radius. By combining lensing (total) and

  6. Effect of Cesium Pressure on Thermionic Stability

    Energy Technology Data Exchange (ETDEWEB)

    Schock, Alfred

    1969-08-01

    It is shown that under certain conditions of heat input, reservoir temperature, and load voltage or resistance a thermionic converter can equilibrate at two radically different operation points, corresponding to conditions of high and low cesium coverage. Moreover, abrupt transitions between these operating regimes, accompanied by a temperature rise of hundreds of degrees, can occur whenever the critical heat generation rate for a given reservoir temperature is exceeded. To provide an adequate safety margin against such an occurrence, thermionic systems must be operated at relatively high cesium pressures, even though this may cause some performance degradation. This paper consists of two parts. The first explains the above effect with reference to a single converter. The second part illustrates the effect of cesium reservoir temperatures on the dynamic behavior of an open-loop thermionic reactor following a small reactivity perturbation.

  7. A mass spectrometric system for analyzing thermal desorption spectra of ion-implanted argon and cesium in tungsten. Ph.D. Thesis

    Science.gov (United States)

    Wood, G. M., Jr.

    1974-01-01

    A mass spectrometric system for determining the characteristics of materials used in instrumental development and aerospace applications was developed. The desorption spectra of cesium that was ion-implanted into polycrystalline tungsten and the effects on the spectra of bombardment of the tungsten by low energy (70 eV) electrons were investigated. Work function changes were measured by the retarding potential diode method. Flash desorption characteristics were observed and gas-reaction mechanisms of the surface of heated metal filaments were studied. Desorption spectra were measured by linearly increasing the sample temperature at a selected rate, the temperature cycling being generated from a ramp-driven dc power supply, with the mass spectrometer tuned to a mass number of interest. Results of the study indicate an anomolous desorption mechanism following an electron bombardment of the sample surface. The enhanced spectra are a function of the post-bombardment time and energy and are suggestive of an increased concentration of cesium atoms, up to 10 or more angstroms below the surface.

  8. Non-Linear Beam Transport System for the LENS 7 MeV Proton Beam

    CERN Document Server

    Jones, William P; Derenchuk, Vladimir Peter; Rinckel, Thomas; Solberg, Keith

    2005-01-01

    A beam transport system has been designed to carry a high-intensity low-emittance proton beam from the exit of the RFQ-DTL acceleration system of the Indiana University Low Energy Neutron System (LENS)* to the neutron production target. The goal of the design was to provide a beam of uniform density over a 3cm by 3cm area at the target. Two octupole magnets** are employed in the beam line to provide the necessary beam phase space manipulations to achieve this goal. First order calculations were done using TRANSPORT and second order calculations have been performed using TURTLE. Second order simulations have been done using both a Gaussian beam distribution and a particle set generated by calculations of beam transport through the RFQ-DTL using PARMILA. Comparison of the design characteristics with initial measurements from the LENS commissioning process will be made.

  9. Corneo-scleral contact lens in a piggyback system for keratoconus: A case report.

    Science.gov (United States)

    Porcar, Esteban; Montalt, Juan Carlos; España-Gregori, Enrique; Peris-Martínez, Cristina

    2017-06-01

    We describe a case of fitting a corneo-scleral contact lens with a multi-aspheric geometry design (MAGD CScL) on top of a daily silicone hydrogel lens (piggyback system) for keratoconus management. A 48-year-old man using soft toric contact lenses required an improvement in the unsatisfactory quality of his vision. He presented with bilateral asymmetric keratoconus with high myopia in the right eye (RE) and severe myopia in the left eye (LE). In addition, he had low vision in his LE because of a maculopathy. He was fitted with MAGD CScL to correct his irregular astigmatism. A diagnostic trial set was used in the fitting process and the patient was assessed according to a standardised fitting methodology. Visual acuity, corneal topography and contrast sensitivity were evaluated. The follow-up period was 1year. The best spectacle-corrected visual acuity was 0.5 logMAR for the RE with -10 D/-5 D×60° and 2 logMAR for the LE with -20 D/-3 D×105°. After fitting MAGD CScL, visual acuity improved significantly to 0.1 logMAR for the RE and 1.3 logMAR for the LE, as well as contrast sensitivity. The fitting parameters of the base curve, diameter, and power were 7.05mm, 12.60mm, -18.50 D and 7.15mm, 12.60mm, -19 D for the RE and LE, respectively. Optimal fitting characteristics were found in terms of lens position and lens movement. To increase the time of MAGD CScL wear, they piggybacked on daily silicone hydrogel lenses of low power (-0.5 D). The patient reported being comfortable with this piggyback system for approximately 15h a day. After 1year of using the piggyback system, visual quality and wearing time were maintained. In addition, no adverse ocular effects were found during this period. This case report shows that in this patient a MAGD CScL could be fitted successfully on a daily silicone hydrogel lens in a piggyback system for keratoconus management, providing good visual quality along with prolonged use times and without adverse effects on the cornea

  10. Systemic Arterial Hypertension in Patients Exposed to Cesium-137 in Goiânia-GO: Prevalence Study.

    Science.gov (United States)

    Rodrigues, José Victor Rabelo; Pinto, Murillo Macêdo; Figueredo, Roberto Miller Pires; Lima, Helen de; Souto, Rafael; Sacchetim, Sylvana de Castro

    2017-01-01

    Systemic Arterial Hypertension (SAH) in the Brazilian population, in populations not exposed to Césio-137, presents a prevalence of 28% nationwide. However, in the group of radioactivity victims, these values are unknown. To analyze the prevalence of hypertension in patients exposed to Cesium-137 in Goiânia, enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) (Radioactivtity Victims Monitoring System) of the Centro de Assistência aos Radioacidentados (C.A.R.A) (Assistence Center for Radioactivity Victims). This is a descriptive, observational cross-sectional epidemiological study carried out in Goiânia-Goiás, from August 2013 to October 2014, with a group of patients enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) of the Centro de Assistência a Radioacidentados (C.A.R.A.). A total of 102 radioactive patients were divided into two groups: group 1 with 40 and group 2 with 62 participants. A field survey was conducted with a closed and semi-structured questionnaire in which the following contexts were addressed: sociodemographic profile, life habits and personal background. A database was created using the Google Forms application from the Google Web technologies company. The duly collected and stored data were imported and analyzed in the statistical software SPSS, version 21. The prevalence of SAH reached a total of 25% (12 individuals) of the 48 interviewees, 50% of women (24) and 50% of men (24), of which 22.9% (11) of the radioactivity victims revealed to be smokers. The prevalence of SAH in the radioactivity victims population is similar to that of the population in general. A Hipertensão Arterial Sistêmica (HAS) na população brasileira, em populações não expostas ao Césio-137, apresenta prevalência de 28% em âmbito nacional. Porém, no grupo de radioacidentados, esses valores são desconhecidos. Analisar a prevalência da HAS em pacientes expostos ao Césio-137 ocorrido em Goiânia, cadastrados no

  11. A wide-FoV athermalized infrared imaging system with a two-element lens

    Science.gov (United States)

    Feng, Bin; Shi, Zelin; Zhao, Yaohong; Liu, Haizheng; Liu, Li

    2017-12-01

    For infrared imaging systems to achieve wide field of view (FoV), wide operating temperature and low weight, this work designs a wide-FoV athermalized infrared imaging system (AIIS) with a two-element lens. Its principle, design, manufacture, measurement and performance validation are successively discussed. The two-element lens contains four surfaces, where three aspheric surfaces are introduced to reduce optical off-axis aberrations and a cubic surface is introduced to achieve athermalization. The key coding mask containing an aspheric surface and a cubic surface is manufactured by nano-metric machining of ion implanted material (NiIM). Experimental results validate that our wide-FoV wavefront coding AIIS has a full FoV of 26.10° and an operating temperature over -20 °C to +70 °C.

  12. Frequency Invariant Beam Steering for Short-Pulse Systems with a Rotman Lens

    Directory of Open Access Journals (Sweden)

    Andreas Lambrecht

    2010-01-01

    Full Text Available A promising approach for beam steering of high-voltage transient signals for HPEM-systems (High Power Electro Magnetic is presented. The inherent capability of the Rotman lens to provide true time delays is used to develop a prototype beam steering device for an antielectronics HPEM system in the frequency range from 350 MHz to 5 GHz. Results of analytical calculations, simulations, and measurements from a hardware prototype are presented. The detailed mechanical setup of the Rotman lens is presented. Additionally the output pulses are investigated when inputting a Gaussian-like transient signal. Then time domain measures of quality (full width at half maximum, ringing, delay spread, maximum of transfer function are investigated for these output transients, and the simulation and measurement results are compared. A concluding analysis of the realizable time domain array pattern shows the radiated pulse form.

  13. Conceptualizing HRM system strength through a cross-cultural lens

    NARCIS (Netherlands)

    Farndale, E.; Sanders, K.

    2017-01-01

    To date, literature on HRM system strength has been largely universalistic, that is, it has not considered the implications of context. This is problematic as it overlooks a more detailed exploration of the outcomes of HRM system strength in different situational settings. Adopting a contingency

  14. The equity lens in the health care performance evaluation system.

    Science.gov (United States)

    Barsanti, Sara; Nuti, Sabina

    2014-01-01

    The main objective of this paper is to describe how indicators of the equity of access to health care according to socioeconomic conditions may be included in a performance evaluation system (PES) in the regional context level and in the planning and strategic control system of healthcare organisations. In particular, the paper investigates how the PES adopted, in the experience of the Tuscany region in Italy, indicators of vertical equity over time. Studies that testify inequality of access to health services often remain just a research output and are not used as targets and measurements in planning and control systems. After a brief introduction to the concept of horizontal and vertical equity in health care systems and equity measures in PES, the paper describes the 'equity process' by which selected health indicators declined by socioeconomic conditions were shared and used in the evaluation of health care institutions and in the CEOs' rewarding system, and subsequently analyses the initial results. Results on the maternal and child path and the chronicity care path not only show improvements in addressing health care inequalities, but also verify whether the health system responds appropriately to different population groups. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Investigation of a metamaterial slab lens and an imaging system based on an ellipsoidal cavity.

    Science.gov (United States)

    Kordi, Mahdi; Mirsalehi, Mir Mojtaba

    2017-06-01

    A slab metamaterial lens with a refractive index of -1 is capable of producing a perfect image, since it transfers all the plane waves from the object plane to the image plane without creating any distortion in their amplitudes and phases. However, its practical implementation encounters several challenges. In this paper, a lossless slab metamaterial lens is investigated using the ray-tracing technique. We also discuss propagating waves and evanescent waves and investigate an imaging system based on an ellipsoidal cavity. It is shown that since an ellipsoidal cavity transfers the beams from one of its foci to the other with the same amplitude and phase, it acts similarly to a metamaterial slab lens of n=-1. Therefore, this structure can be used as a subwavelength resolution imaging system. Also, it does not suffer from chromatic aberration, since all the rays transmitted from one focus pass through the other independent of the wavelength. Another important advantage of this system, compared to metamaterial-based superlenses, is that it can operate at any frequency as long as the dimensions of the cavity are much larger than the wavelength.

  16. Design and optimization of multipole lens and Wien filter systems

    Energy Technology Data Exchange (ETDEWEB)

    Liu Haoning, E-mail: haoning@mebs.co.uk [Munro' s Electron Beam Software Ltd., 14 Cornwall Gardens, London SW7 4AN (United Kingdom); Wang Liping; Rouse, John; Munro, Eric [Munro' s Electron Beam Software Ltd., 14 Cornwall Gardens, London SW7 4AN (United Kingdom)

    2011-07-21

    The differential algebra (DA) method has been employed to compute the optical properties and aberrations up to the fifth order of multipole systems containing electrostatic and magnetic round, quadrupole, hexapole and octopole lenses, and Wien filters. A new software package has been developed, which computes the geometrical and chromatic aberrations up to the fifth order by using a single DA ray trace. It also has an optimization module where a weighted set of aberrations can be minimized by the automatic adjustment of a set of user-defined system variables. In this paper, we present our new method for designing and optimizing multipole systems including Wien filters, and illustrate its application with three relevant examples.

  17. Design and optimization of multipole lens and Wien filter systems

    Science.gov (United States)

    Liu, Haoning; Wang, Liping; Rouse, John; Munro, Eric

    2011-07-01

    The differential algebra (DA) method has been employed to compute the optical properties and aberrations up to the fifth order of multipole systems containing electrostatic and magnetic round, quadrupole, hexapole and octopole lenses, and Wien filters. A new software package has been developed, which computes the geometrical and chromatic aberrations up to the fifth order by using a single DA ray trace. It also has an optimization module where a weighted set of aberrations can be minimized by the automatic adjustment of a set of user-defined system variables. In this paper, we present our new method for designing and optimizing multipole systems including Wien filters, and illustrate its application with three relevant examples.

  18. Reducing aberration effect of Fourier transform lens by modifying Fourier spectrum of diffractive optical element in beam shaping optical system.

    Science.gov (United States)

    Zhang, Fang; Zhu, Jing; Song, Qiang; Yue, Weirui; Liu, Jingdan; Wang, Jian; Situ, Guohai; Huang, Huijie

    2015-10-20

    In general, Fourier transform lenses are considered as ideal in the design algorithms of diffractive optical elements (DOEs). However, the inherent aberrations of a real Fourier transform lens disturb the far field pattern. The difference between the generated pattern and the expected design will impact the system performance. Therefore, a method for modifying the Fourier spectrum of DOEs without introducing other optical elements to reduce the aberration effect of the Fourier transform lens is proposed. By applying this method, beam shaping performance is improved markedly for the optical system with a real Fourier transform lens. The experiments carried out with a commercial Fourier transform lens give evidence for this method. The method is capable of reducing the system complexity as well as improving its performance.

  19. Thermal properties of cesium molybdate

    International Nuclear Information System (INIS)

    Minato, Kazuo; Fukuda, Kousaku; Takano, Masahide; Sato, Seichi; Ohashi, Hiroshi

    1996-01-01

    Cesium is one of the most important fission products to aid in the understanding and prediction of the behavior of oxide nuclear fuels because of its high mobility, chemical reactivity, and large yield. In postirradiation examinations of the Phoenix reactor fuel pins, the accumulation of cesium and molybdenum between the fuel pellet and cladding was observed, though the chemical form was not determined. In the thermodynamic analyses of chemical states of fission products, Cs 2 MoO 4 was often predicted to exist as a stable compound in oxide fuels. The Cs 2 MoO 4 compound is thermodynamically stable under the conditions of light water reactors, fast breeder reactors, and high-temperature gas-cooled reactors. In the Cs-Mo-O system several phases have been found, and the structural and thermodynamic properties were studied. At room temperature, Cs 2 MoO 4 has an orthorhombic structure and a phase transition occurs at 841 K to a hexagonal structure. Both structures are expected to exist in the fuel, depending on the fuel temperature. However, no data has been available on the thermal properties of CS 2 MoO 4 . In the current work, the thermal expansion and thermal conductivity of Cs 2 MoO 4 were determined, which are the basic data needed to understand and predict the fuel/clad mechanical interaction and fuel temperature

  20. A new lens for supporting and studying science teacher reflections: situating the self in the [activity] system

    Science.gov (United States)

    Criswell, Brett; Calandra, Brendan; Puvirajah, Anton; Brantley-Dias, Laurie

    2015-12-01

    This paper presents a new lens for analyzing written reflections on the teaching experiences of pre-service [science] teachers. The lens, which borrows heavily from Activity Theory, allows science education researchers and teacher educators to identify tensions, disturbances, conflicts, and contradictions within teachers' written reflections as a means to help the participants situate their successes and challenges within the activity systems in which they operate. This paper describes the process through which the lens was crafted, defines the key constructs comprising the lens, applies the lens to the analysis of two purposefully selected reflection documents, and then considers the affordances of the lens. It also discusses how the insights gained from this lens have lead to new ways of facilitating reflection in pre-service science teachers, including the use of Kenneth Snelson's tensegrity sculptures as a metaphor for the goal of reflection. Finally, it connects the tensions identified in the individual reflections of two pre-service science teachers to broader issues being addressed in science education.

  1. Polarization Monitoring of the Lens System JVAS B0218+357

    Directory of Open Access Journals (Sweden)

    Andrew Biggs

    2017-10-01

    Full Text Available Monitoring of the lens system JVAS B0218+357 with the Fermi Gamma-ray Space Telescope measured a different time delay to that derived from radio observations. We have re-analysed three months of archival Very Large Array data to produce variability curves with an average sampling of one epoch per day in total flux, polarized flux and polarization position angle (PPA at 15, 8.4 and 5 GHz. The variability is particularly strong in polarized flux. Dense sampling and improved subtraction of the Einstein ring has allowed us to produce superior variability curves and a preliminary analysis has resulted in a time delay (11.5 days which agrees well with the γ -ray value. Both images of 0218+357 are subject to strong Faraday rotation and depolarization as a result of the radio waves passing through the interstellar medium of the spiral lens galaxy. Our data reveal frequency-dependent variations in the PPA that are different in each image and which must therefore result from variable Faraday rotation in the lens galaxy on timescales of a few days. Our analysis has revealed systematic errors in the polarization position angle measurements that strongly correlate with hour angle. Although we have been able to correct for these, we caution that all VLA polarization observations are potentially affected.

  2. Golden Gravitational Lensing Systems from the Sloan Lens ACS Survey. I. SDSS J1538+5817: One Lens for Two Sources

    Science.gov (United States)

    Grillo, C.; Eichner, T.; Seitz, S.; Bender, R.; Lombardi, M.; Gobat, R.; Bauer, A.

    2010-02-01

    We present a gravitational lensing and photometric study of the exceptional strong lensing system SDSS J1538+5817, identified by the Sloan Lens Advanced Camera for Survey. The lens is a luminous elliptical galaxy at redshift zl = 0.143. Using Hubble Space Telescope public images obtained with two different filters, the presence of two background sources lensed, respectively, into an Einstein ring and a double system is ascertained. Our new spectroscopic observations, performed at the Nordic Optical Telescope, reveal unequivocally that the two sources are located at the same redshift zs = 0.531. We investigate the total (luminous and dark) mass distribution of the lens between 1 and 4 kpc from the galaxy center by means of parametric and non-parametric lensing codes that describe the multiple images as point-like objects. Bootstrapping and Bayesian analyses are performed to determine the uncertainties on the quantities relevant to the lens mass characterization. Several disparate lensing models provide results that are consistent, given the errors, with those obtained from the best-fit model of the lens mass distribution in terms of a singular power-law ellipsoid model. In particular, the lensing models agree on: (1) reproducing accurately the observed positions of the images; (2) predicting a nearly axisymmetric total mass distribution, centered and oriented as the light distribution; (3) measuring a value of 8.11+0.27 -0.59 × 1010 M sun for the total mass projected within the Einstein radius of 2.5 kpc; and (4) estimating a total mass density profile slightly steeper than an isothermal one (ρ (r) ∝ r^{-2.33^{+0.43}_{-0.20}}). A fit of the Sloan Digital Sky Survey multicolor photometry with composite stellar population models provides a value of 20+1 -4 × 1010 M sun for the total mass of the galaxy in the form of stars and of 0.9+0.1 -0.2 for the fraction of projected luminous over total mass enclosed inside the Einstein radius. By combining lensing (total

  3. Cesium-137: A physiological disruptor?

    International Nuclear Information System (INIS)

    Souidi, Maamar; Grison, Stephane; Dublineau, Isabelle; Aigueperse, Jocelyne; Lestaevel, Philippe

    2013-01-01

    Today, radiation protection is a major issue for the nuclear industry throughout the world, particularly in France. The 2011 disaster of Fukushima Dai-ichi has brought back to public attention questions about the risks associated with nuclear power for civilian purposes. The risk of accidental release of radioactive molecules, including cesium-137 ( 137 Cs), from these facilities cannot be completely eliminated. The non-cancer-related health consequences of chronic exposure to this radionuclide remain poorly understood. After absorption, cesium is distributed throughout the body. The toxicity of 137 Cs is due mainly to its radiological properties. Studies in humans report that 137 Cs impairs the immune system and induces neurological disorders. Children appear more susceptible than adults to its toxic effects. In animals, and most particularly in rodents, low-dose internal contamination disrupts the sleep-wake cycle, but without behavioural disorders. Impairment of the cardiovascular system has also been observed. Physiologic systems such as the metabolism of vitamin D, cholesterol and steroid hormones are altered, although without leading to the emergence of diseases with clinical symptoms. Recently, a metabolomics study based on contamination levels comparable to those around Chernobyl after the accident showed that it is possible to identify individual rats chronically exposed to low doses of 137 Cs, even though the exposure was too low to affect the standard clinical markers. In conclusion, the scientific evidence currently available, particularly that from experimental animal models exposed to chronic contamination, suggests that 137 Cs is likely to affect many physiologic and metabolic functions. Thus, it could contribute, with other artificial substances in the environment, to increasing the risk of developing non-cancer diseases in some regions. (authors)

  4. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N. N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  5. Biosorption of stable cesium by chemically modified biomass of Sargassum glaucescens and Cystoseira indica in a continuous flow system.

    Science.gov (United States)

    Dabbagh, R; Ebrahimi, M; Aflaki, F; Ghafourian, H; Sahafipour, M H

    2008-11-30

    Pretreatment of biosorbents have been suggested to modify the surface characteristics which could improve biosorption process. Stable cesium biosorption was studied in continuous fixed-bed column by chemically modified biosorbents. Two kinds of brown algae (Sargassum glaucescens and Cystoseira indica) were treated with chemical agents including formaldehyde (FA), glutaraldehyde (GA), potassium hexacyanoferrate (HCF), FA and HCF, and GA and HCF. The highest biosorption capacity (BC) was obtained from C. indica treated with FA (63.5 mg Cs/g biomass) and S. glaucescens treated with FA and HCF (62 mg Cs/g biomass). To study the effect of the best treatments on the BC, the concentration of each treatment agent was decreased. With decreasing FA agent for C. indica treatment, the BC dropped. Treatment of 1g S. glaucescens biomass with 2.2g FA and then 0.18 g HCF resulted in the highest BC (73.08 mg Cs/g dry biomass) which was 35.8 times higher than intact S. glaucescens.

  6. Biosorption of stable cesium by chemically modified biomass of Sargassum glaucescens and Cystoseira indica in a continuous flow system

    Energy Technology Data Exchange (ETDEWEB)

    Dabbagh, R. [Nuclear Science Research School, Nuclear Science Technology Research Institute, Tehran (Iran, Islamic Republic of)], E-mail: rdabagh@yahoo.com; Ebrahimi, M.; Aflaki, F.; Ghafourian, H.; Sahafipour, M.H. [Nuclear Science Research School, Nuclear Science Technology Research Institute, Tehran (Iran, Islamic Republic of)

    2008-11-30

    Pretreatment of biosorbents have been suggested to modify the surface characteristics which could improve biosorption process. Stable cesium biosorption was studied in continuous fixed-bed column by chemically modified biosorbents. Two kinds of brown algae (Sargassum glaucescens and Cystoseira indica) were treated with chemical agents including formaldehyde (FA), glutaraldehyde (GA), potassium hexacyanoferrate (HCF), FA and HCF, and GA and HCF. The highest biosorption capacity (BC) was obtained from C. indica treated with FA (63.5 mg Cs/g biomass) and S. glaucescens treated with FA and HCF (62 mg Cs/g biomass). To study the effect of the best treatments on the BC, the concentration of each treatment agent was decreased. With decreasing FA agent for C. indica treatment, the BC dropped. Treatment of 1 g S. glaucescens biomass with 2.2 g FA and then 0.18 g HCF resulted in the highest BC (73.08 mg Cs/g dry biomass) which was 35.8 times higher than intact S. glaucescens.

  7. Cesium pre-implantation of embedded biological sections

    International Nuclear Information System (INIS)

    Galle, Pierre; Levi-Setti, Riccardo; Labejof, Lise; Kaitasov, Odile

    2008-01-01

    An ion implantation system which allows the implantation of a large surface of a specimen has been used to obtain an homogeneous enrichment with cesium of embedded biological tissues sections. In such a specimen, containing already oxygen at a high concentration, the addition of cesium allows both positive and negative secondary ions to be studied with the highest sensitivity, using the same primary ion source.

  8. Resolution limit of probe-forming systems with magnetic quadrupole lens triplets and quadruplets

    International Nuclear Information System (INIS)

    Ponomarev, A.G.; Melnik, K.I.; Miroshnichenko, V.I.; Storizhko, V.E.; Sulkio-Cleff, B.

    2003-01-01

    Over the past decade, in MeV ion beam microanalysis efforts to achieve a spatial resolution better than 0.1 μm with a beam current of ∼100 pA have been connected with microprobes of new generation where the probe is formed by means of separated magnetic quadrupole lens structures . However, as was pointed out in , no dramatic improvements in spatial resolution have been produced so far. For better understanding of the situation the authors carried out theoretical studies of multiparameter sets of probe-forming systems based on separated triplets and quadruplets of magnetic quadrupole lenses. Comparisons were made between the highest current values attained at different systems for a given beam spot size. The maximum parasitic sextupole and octupole field components were found whose contributions to spot broadening are tolerable. It is shown that the use of modern electrostatic accelerators and precision magnetic quadrupole lenses makes it possible to eliminate the effect of chromatic aberrations and second- and third-order parasitic aberrations resulting from distortions of the quadrupole lens symmetry. Therefore probe-forming systems with triplets and quadruplets of magnetic quadrupole lenses have a lower theoretical spatial resolution limit which is restricted mainly by intrinsic spherical third-order aberrations in state-of-the-art microprobes

  9. Progress toward Brazilian cesium fountain second generation

    Science.gov (United States)

    Bueno, Caio; Rodriguez Salas, Andrés; Torres Müller, Stella; Bagnato, Vanderlei Salvador; Varela Magalhães, Daniel

    2018-03-01

    The operation of a Cesium fountain primary frequency standard is strongly influenced by the characteristics of two important subsystems. The first is a stable frequency reference and the second is the frequency-transfer system. A stable standard frequency reference is key factor for experiments that require high accuracy and precision. The frequency stability of this reference has a significant impact on the procedures for evaluating certain systematic biases in frequency standards. This paper presents the second generation of the Brazilian Cesium Fountain (Br-CsF) through the opto-mechanical assembly and vacuum chamber to trap atoms. We used a squared section glass profile to build the region where the atoms are trapped and colled by magneto-optical technique. The opto-mechanical system was reduced to increase stability and robustness. This newest Atomic Fountain is essential to contribute with time and frequency development in metrology systems.

  10. Irreversible Wash Aid Additive for Cesium Mitigation: Phase II. Selection and/or Modification of COTS Field Portable Waste Water Systems

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Michael [Argonne National Lab. (ANL), Argonne, IL (United States); Mertz, Carol [Argonne National Lab. (ANL), Argonne, IL (United States); Kivenas, Nadia [Argonne National Lab. (ANL), Argonne, IL (United States); Magnuson, Matthew [US Environmental Protection Agency (EPA), Cincinnati, OH (United States).

    2015-01-01

    After an accidental or malicious release of radioactivity, large urban areas may be contaminated, compromising response efforts by first responders and law enforcement officials. In addition, some public services (e.g., drinking water and wastewater treatment, electrical power distribution, etc.) may be disrupted. In such an event, it may be important to deploy mitigation efforts in certain areas to restore response activities and public services (Fig. S-1). This report explores the state-of-the-art approach for a system to rapidly return critical infrastructure components to service following a cesium-137 (Cs-137) radiological dispersal device (RDD) release while avoiding the spread of Cs-137 beyond its original deposition area and minimizing the amount of Cs-137-contaminated wastewater. Specifically, we describe a wash system consisting of chemical additives added to fire hydrant water and irreversible solid sequestering agents added as the water is collected and treated for recycle in situ. The wash system is intended to be a rapidly deployable, cost-effective means of mitigating an urban setting for the purpose of restoring critical infrastructure and operational activities after a radiological release.

  11. Lamp system with a single second-lens newly designed by using the least square method for 4 LEDs

    Science.gov (United States)

    Jo, Jae Heung; Ryu, Jae Myung; Hong, Chun Gang

    2014-05-01

    It is common for many companies to use multiple LEDs to enhance the brightness of a LED lamp and, in general, four LEDs are used in the LED lamp systems. Moreover, the second-lens must be used to obtain a straight uniform illumination from LED lights. Where four LEDs are used, four second-lenses are also assembled conventionally and those four units of second-lenses are manufactured from a single mold and assembled together with the LEDs. However, this study introduces a new method of using the Least Square Method to get a uniform illumination with the divergence angle of 40 degrees with a new single injection molded lens. Thanks to this optical design with a single lens, the assembling process of LED lamp system was simplified by eliminating the complicated assembly procedure. Also, the uniformity of illumination of this newly designed lamp system was less than 14.1%.

  12. Metrology of cesium ion thrusters

    International Nuclear Information System (INIS)

    Benoist, Roger; Labbe, Jean; Le Grives, Emile

    1974-01-01

    The various controls necessary to characterize cesium ion thrusters are presented. The following metrological process was developed by the ONERA: control of the thermal equilibrium and regulation of the temperature of the ionizer and of the cesium supply device, control of the ion current emission characterized both globally and locally, control of the ionization yield by the determination of the number of neutral cesium atoms by means of an appropriate detector and analysis of the structure of the beam by mapping the ionic current density. This characterization is completed by the results of cyclic regime tests runs reproducing the working conditions in satellites [fr

  13. Cesium migration experiments in different media

    International Nuclear Information System (INIS)

    Tello, C.C.O. de

    1992-01-01

    The environmental impact caused by the radioactive waste disposal depends on many factors, mainly on the release pathways of the radionuclides from the waste product to the environment. The migration of the radioelements through the different barriers, which compose the disposal system, is considered the main via for this release. This paper describes the experiments carried out to improve the cemented waste quality, as well to assess the cesium migration in different media. (author)

  14. Compliance among soft contact lens wearers.

    OpenAIRE

    Kuzman, Tomislav; Barišić Kutija, Marija; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurišić, Darija; Škegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-01-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in ...

  15. Preparation, Characterization, and In Vivo Pharmacoscintigraphy Evaluation of an Intestinal Release Delivery System of Prussian Blue for Decorporation of Cesium and Thallium

    Directory of Open Access Journals (Sweden)

    Nidhi Sandal

    2017-01-01

    Full Text Available Background. Prussian blue (PB, ferric hexacyanoferrate is approved by US-FDA for internal decorporation of Cesium-137 (137Cs and Thallium-201 (201Tl. Aim. Since PB is a costly drug, pH-dependent oral delivery system of PB was developed using calcium alginate matrix system. Methods. Alginate (Alg beads containing PB were optimized by gelation of sodium alginate with calcium ions and effect of varying polymer concentration on encapsulation efficiency and release profile was investigated. Scanning electron microscopy (SEM was carried out to study surface morphology. Adsorption efficacy of Alg-PB beads for 201Tl was evaluated and compared with native PB. In vivo pH-dependent release of the formulation was studied in humans using gamma scintigraphy. Results. Encapsulation efficiencies of Alg-PB beads with 0.5, 1.0, 1.5, and 2.0% polymer solution were 99.9, 91, 92, and 93%, respectively. SEM and particle size analysis revealed differences between formulations in their appearance and size distribution. No drug release was seen in acidic media (pH of 1-2 while complete release was observed at pH of 6.8. Dissolution data was fitted to various mathematical models and beads were found to follow Hixson-Crowell mechanism of release. The pH-dependent release of beads was confirmed in vivo by pharmacoscintigraphy in humans.

  16. Cesium diffusion in graphite

    International Nuclear Information System (INIS)

    Evans, R.B. III; Davis, W. Jr.; Sutton, A.L. Jr.

    1980-05-01

    Experiments on diffusion of 137 Cs in five types of graphite were performed. The document provides a completion of the report that was started and includes a presentation of all of the diffusion data, previously unpublished. Except for data on mass transfer of 137 Cs in the Hawker-Siddeley graphite, analyses of experimental results were initiated but not completed. The mass transfer process of cesium in HS-1-1 graphite at 600 to 1000 0 C in a helium atmosphere is essentially pure diffusion wherein values of (E/epsilon) and ΔE of the equation D/epsilon = (D/epsilon) 0 exp [-ΔE/RT] are about 4 x 10 -2 cm 2 /s and 30 kcal/mole, respectively

  17. Research on the processing technology of medium-caliber aspheric lens in the optoelectronic integrated test system

    Science.gov (United States)

    Liu, Dan; Yu, Xin-ying; Wang, Wei

    2016-10-01

    In the optoelectronic integrated test system, surface profile and finish of the optical element are put forward higher request. Taking an aspherical quartz glass lens with a diameter of 200mm as example, taking Preston hypothesis as the theoretical basis, analyze the influence of surface quality of various process parameters, including the workpiece and the tool axis spindle speed, wheel type, concentration polishing, polishing mold species, dwell time, polishing pressure and other parameters. Using CNC method for the surface profile and surface quality of the lens were investigated. Taking profilometer measurement results as a guide, by testing and simulation analysis, process parameters were improved constantly in the process of manufacturing. Mid and high frequency error were trimmed and improved so that the surface form gradually converged to the required accuracy. The experimental results show that the final accuracy of the surface is less than 2µm and the surface finish is, which fulfils the accuracy requirement of aspherical focusing lens in optical system.

  18. Acanthamoeba keratitis: synergy between amebic and bacterial cocontaminants in contact lens care systems as a prelude to infection.

    Science.gov (United States)

    Bottone, E J; Madayag, R M; Qureshi, M N

    1992-01-01

    We encountered a patient with Acanthamoeba keratitis whose contact lens care solution contained numerous trophozoites and cysts admixed with Xanthomonas maltophilia organisms, many of which were adherent to the trophozoite surface and internalized within endocytic vacuoles. Because of this finding, we investigated the role of bacterial cocontaminants in contact lens care systems as substrates for the growth of Acanthamoeba spp. Individual cocultivation of Acanthamoeba castellanii and A. polyphaga with X. maltophilia, Flavobacterium breve, and Pseudomonas paucimobilis showed better enhancement (1.5x) of ameba growth after 96 h than that obtained in the presence of Staphylococcus aureus, S. epidermidis, and Escherichia coli, the standard cocultivation species used for isolation of amebae from clinical specimens. Our data suggest that contamination of contact lens care systems with Acanthamoeba spp. and a bacterial species capable of supporting amebic growth may be the first step in the pathogenesis of ameba-induced keratitis by the provision of large inocula of amebae. Images PMID:1401013

  19. The simulation of three-dimensional ray tracing and parameters optimization in DPL lens duct coupling system

    Science.gov (United States)

    Fan, Shuwei; Zhang, Yan; Shen, Yuting

    2010-06-01

    DPL coupling system was researched in this paper. First, the mathematic model of 3D and 2D light transmission in hollow duct was analyzed and compared. Then the 3D simulation software for all rays of the coupling system -lens duct was developed. The influence of various structural parameters of the hollow lens duct to the energy and the beam distribution were discussed with the help of developed software. The structural parameters such as the duct length, the lens radius, the size of the input and output ends were researched and were optimized to get higher efficiency and better beam distribution. Finally, the energy conversion efficiency and the beam spatial distribution of before and after optimization were compared. The results showed that the efficiency and the distribution of energy were well improved after the optimization.

  20. Design and Tests of a High-Performance Long-Wave Infrared Refractive Thermal Imager: Freeform Lens in Coaxial System

    Directory of Open Access Journals (Sweden)

    Jinjin Chen

    2017-11-01

    Full Text Available In this paper, we used a freeform lens in a long-wave, un-cooled, refractive infrared (IR thermal imager and present the design strategy and test results. This optical system is composed of only one freeform lens and several spheres. It can correct the distortion issue inherent to wide field-of-view systems more effectively, and achieve a better thermal imaging performance simultaneously compared to traditional aspheric optical lenses. Such a design model can alleviate the calculation load and cater for the demand of the ultra-precision turning on single crystal germanium. It satisfies the design idea of freeform surfaces with machining feasibility. The refractive freeform IR imager can be realized from the theoretical design to the engineering applications. The research contents of this paper are helpful for the further application of the freeform lens to a more complex cooled infrared refractive thermal imager.

  1. A new highly integrated design and novel lens system for the CSIRO/GEMOC nuclear probe

    International Nuclear Information System (INIS)

    Ryan, C.G.; Griffin, W.L.; Sie, S.H.; Cripps, G.; Suter, G.F.; Jamieson, D.N.; Ryan, C.G.; Griffin, W.L.

    1998-01-01

    The landscape of microanalysis in the geosciences has changed dramatically in the past few years, and with it the role of the Nuclear Microprobe (NMP). The emphasis of NMP applications has shifted to the advanced complementary techniques of quantitative trace-element imaging, in situ non-destructive fluid and solid inclusion analysis, light element microanalysis using PIGE, lattice location using ion micro-channeling, and to applications requiring finer spatial resolution. Recent success of a collaborative ARC bid by the National Key Centre for the Geochemical Evolution and Metallogeny of Continents (GEMOC) and the CSIRO has enabled the development of a new Nuclear Microprobe at the CSIRO designed to meet this challenge and to fully exploit the potential of the NMP in geology. The instrument and some of its features are described. It uses a novel quintuplet magnetic quadrupole lens system, computer controlled beam-shaping, high-resolution microscope optics and a close geometry detector system

  2. The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery.

    Science.gov (United States)

    Jones, Jason J; Chu, Jeffrey; Graham, Jacob; Zaluski, Serge; Rocha, Guillermo

    2016-01-01

    The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%-12.0% (Psystem also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity.

  3. Decision Support System to Choose Digital Single Lens Camera with Simple Additive Weighting Method

    Directory of Open Access Journals (Sweden)

    Tri Pina Putri

    2016-11-01

    Full Text Available One of the technologies that evolve today is Digital Single Lens Reflex (DSLR camera. The number of products makes users have difficulties to choose the appropriate camera based on their criteria. Users may utilize several ways to help them choosing the intended camera such as using magazine, internet, and other media. This paper discusses about a web based decision support system to choose cameras by using SAW (Simple Additive Weighting method in order to make the decision process more effective and efficient. This system is expected to give recommendations about the camera which is appropriate with the user’s need and criteria based on the cost, the resolution, the feature, the ISO, and the censor. The system was implemented by using PHP and MySQL. Based on the result of questionnaire distributed to 20 respondents, 60% respondents agree that this decision support system can help users to choose the appropriate camera DSLR in accordance with the user’s need, 60% of respondents agree that this decision support system is more effective to choose DSLR camera and 75% of respondents agree that this system is more efficient. In addition, 60.55% of respondents agree that this system has met 5 Es Usability Framework.

  4. Simulation model of a new solar laser system of Fresnel lens according to real observed solar radiation data in

    Directory of Open Access Journals (Sweden)

    Yasser A. Abdel-Hadi

    2015-12-01

    Full Text Available A new simulation model of a new solar pumped laser system was tested to be run in Helwan in Egypt (latitude φ = 29°52′N, longitude λ = 31°21′E and elevation = 141 m as an example of an industrial polluted area. The system is based on concentrating the solar radiation using a Fresnel lens on a laser head fixed on a mount tracking the sun during the day and powered by a DC battery. Two cases of this model are tested; the first one is the model consisting of a Fresnel lens and a two-dimensional Compound Parabolic Concentrator (CPC, while the other is the model consisting of a Fresnel lens and a three-dimensional Compound Parabolic Concentrator (CPC. The model is fed by real actual solar radiation data taken in Helwan Solar Radiation Station at NRIAG in the various seasons in order to know the laser power got from such a system in those conditions. For the system of Fresnel lens and 2D-CPC, an average laser output power of 1.27 W in Winter, 2 W in Spring, 5 W in Summer and 4.68 W in Autumn respectively can be obtained. Accordingly, the annual average output power for this system is 3.24 W. For the system of Fresnel lens and 3D-CPC, an average laser output power of 3.28 W in Winter, 3.55 W in Spring, 7.56 W in Summer and 7.13 W in Autumn respectively can be obtained. Accordingly, the annual average output power for this system is 5.38 W.

  5. Simulation model of a new solar laser system of Fresnel lens according to real observed solar radiation data in

    Science.gov (United States)

    Abdel-Hadi, Yasser A.; Ghitas, A.; Abulwfa, A.; Sabry, M.

    2015-12-01

    A new simulation model of a new solar pumped laser system was tested to be run in Helwan in Egypt (latitude φ = 29°52‧N, longitude λ = 31°21‧E and elevation = 141 m) as an example of an industrial polluted area. The system is based on concentrating the solar radiation using a Fresnel lens on a laser head fixed on a mount tracking the sun during the day and powered by a DC battery. Two cases of this model are tested; the first one is the model consisting of a Fresnel lens and a two-dimensional Compound Parabolic Concentrator (CPC), while the other is the model consisting of a Fresnel lens and a three-dimensional Compound Parabolic Concentrator (CPC). The model is fed by real actual solar radiation data taken in Helwan Solar Radiation Station at NRIAG in the various seasons in order to know the laser power got from such a system in those conditions. For the system of Fresnel lens and 2D-CPC, an average laser output power of 1.27 W in Winter, 2 W in Spring, 5 W in Summer and 4.68 W in Autumn respectively can be obtained. Accordingly, the annual average output power for this system is 3.24 W. For the system of Fresnel lens and 3D-CPC, an average laser output power of 3.28 W in Winter, 3.55 W in Spring, 7.56 W in Summer and 7.13 W in Autumn respectively can be obtained. Accordingly, the annual average output power for this system is 5.38 W.

  6. Distribution of cesium between colloid-rock phases-establishment of experimental system and investigation of Cs distribution between colloid and rock

    International Nuclear Information System (INIS)

    Nakata, Kotaro

    2006-01-01

    Distribution and re-distribution of cesium between 3-phases (colloid, rock and water) was investigated. Analcite and bentonite colloid ware used as colloid phase and muscovite was used as rock phase. Before investigating the distribution between 3-phases, sorption and desorption behavior of Cs on analcite colloid, bentonite colloid and muscovite was investigated. It was found some fraction of Cs sorbed irreversibly on analcite colloid, while Cs sorbed reversibly on bentonite colloid. The experimental system was established for assessment of the distribution of nuclides between 3-phases by using combination of membrane filter and experimental cell. Since colloid and muscovite were separated by membrane filter, sorption of colloid on muscovite could be prevented and we could obtain distribution of Cs as ion. The distribution of Cs between 3-phases were obtained by this experimental system. Furthermore, re-distribution experiment was also carried out by using this system. After 7 days contact of colloid with Cs, distribution of sorbed Cs on colloid to liquid or muscovite phase was investigated. Comparing sorption and desorption isotherm with the distribution of Cs between 3-phases, it was found that Kd value of colloid (ratio of Cs concentration in liquid phase to amount of sorbed Cs on colloid phase) estimated in 2-phases (water and colloid) is different from that in 3-phases. Furthermore, in the case of analcite colloid, Kd value of colloid obtained in 3-phases distribution experiment was different from that obtained in re-distribution experiment. This is considered because of the irreversibility of Cs sorption on analcite colloid. Thus, it was found distribution of Cs in 3-phases was not predictable from sorption and desorption isotherm or Kd value of 2-phases (water-rock, water-colloid). (author)

  7. Off-axis holographic lens spectrum-splitting photovoltaic system for direct and diffuse solar energy conversion.

    Science.gov (United States)

    Vorndran, Shelby D; Chrysler, Benjamin; Wheelwright, Brian; Angel, Roger; Holman, Zachary; Kostuk, Raymond

    2016-09-20

    This paper describes a high-efficiency, spectrum-splitting photovoltaic module that uses an off-axis volume holographic lens to focus and disperse incident solar illumination to a rectangular shaped high-bandgap indium gallium phosphide cell surrounded by strips of silicon cells. The holographic lens design allows efficient collection of both direct and diffuse illumination to maximize energy yield. We modeled the volume diffraction characteristics using rigorous coupled-wave analysis, and simulated system performance using nonsequential ray tracing and PV cell data from the literature. Under AM 1.5 illumination conditions the simulated module obtained a 30.6% conversion efficiency. This efficiency is a 19.7% relative improvement compared to the more efficient cell in the system (silicon). The module was also simulated under a typical meteorological year of direct and diffuse irradiance in Tucson, Arizona, and Seattle, Washington. Compared to a flat panel silicon module, the holographic spectrum splitting module obtained a relative improvement in energy yield of 17.1% in Tucson and 14.0% in Seattle. An experimental proof-of-concept volume holographic lens was also fabricated in dichromated gelatin to verify the main characteristics of the system. The lens obtained an average first-order diffraction efficiency of 85.4% across the aperture at 532 nm.

  8. Hydrogeology in the area of a freshwater lens in the Floridan aquifer system, northeast Seminole County, Florida

    Science.gov (United States)

    Phelps, G.G.; Rohrer, K.P.

    1987-01-01

    Northeast Seminole County, Florida, contains an isolated recharge area of the Floridan aquifer system that forms a freshwater lens completely surrounded by saline water. The freshwater lens covers an area of about 22 sq mi surrounding the town of Geneva, and generally is enclosed by the 25 ft land surface altitude contour. Thickness of the lens is about 350 ft in the center of the recharge area. The geohydrologic units in descending order consist of the post-Miocene sand and shell of the surficial aquifer; Miocene clay, sand, clay, and shell that form a leaky confining bed; and permeable Eocene limestones of the Floridan aquifer system. The freshwater lens is the result of local rainfall flushing ancient seawater from the Floridan aquifer system. Sufficient quantities of water for domestic and small public supply systems are available from the Floridan aquifer system in the Geneva area. The limiting factor for water supply in the area is the chemical quality of the water. Chloride concentrations range from < 20 mg/L in the center of the recharge area to about 5,100 mg/L near the St. Johns River southeast of Geneva. Constituents analyzed included sulfate (range 1 to 800 mg/L), hardness (range 89 to 2,076 mg/L), and iron (range 34 to 6,600 mg/L). Because the freshwater lens results entirely from local recharge, the long-term sustained freshwater yield of the aquifer in the Geneva area depends on the local recharge rate. In 1982, recharge was about 13 inches (13.8 million gal/day). Average recharge for 1941 through 1970 was estimated to be about 11 inches (11.3 million gal/day). Freshwater that recharges the aquifer in the Geneva area is either pumped out or flows north and northeast to discharge near or in the St. Johns River. Average annual outflow from the lens is about 10 in/yr. No measurable change in the size or location of the freshwater lens has occurred since studies in the early 1950's. (Lantz-PTT)

  9. Biaxial-Type Concentrated Solar Tracking System with a Fresnel Lens for Solar-Thermal Applications

    Directory of Open Access Journals (Sweden)

    Tsung Chieh Cheng

    2016-04-01

    Full Text Available In this paper, an electromechanical, biaxial-type concentrated solar tracking system was designed for solar-thermal applications. In our tracking system, the sunlight was concentrated by the microstructure of Fresnel lens to the heating head of the Stirling engine and two solar cells were installed to provide the power for tracking system operation. In order to obtain the maximum sun power, the tracking system traces the sun with the altitude-azimuth biaxial tracing method and accurately maintains the sun’s radiation perpendicular to the plane of the heating head. The results indicated that the position of heating head is an important factor for power collection. If the sunlight can be concentrated to completely cover the heating head with small heat loss, we can obtain the maximum temperature of the heating head of the Stirling engine. Therefore, the temperature of heating head can be higher than 1000 °C in our experiment on a sunny day. Moreover, the results also revealed that the temperature decrease of the heating head is less than the power decrease of solar irradiation because of the latent heat of copper and the small heat loss from the heating head.

  10. Improvement of cesium retention in uranium dioxide by additional phases

    International Nuclear Information System (INIS)

    Gamaury Dubois, S.

    1995-01-01

    The objective of this study is to improve the cesium retention in nuclear fuel. A bibliographic survey indicates that cesium is rapidly released from uranium dioxide in an accident condition. At temperatures higher than 1500 deg C or in oxidising conditions, our experiments show the difficulty of maintaining cesium inside simulated fuel. Two ternary systems are potentially interesting for the retention of cesium and to reduce the kinetics of release from the fuel: Cs 2 O-Al 2 O 3 -SiO 2 et Cs 2 O-ZrO 2 -SO 2 . The compounds CsAISi 2 O 6 and Cs 2 ZrSi 6 O 15 were studied from 1200 deg C to 2000 deg C by thermogravimetric analysis. The volumetric diffusion coefficients of cesium in these structures, in solid state as well as in liquid one, were measured. A fuel was sintered with (Al 2 O 3 + SiO 2 ) or (ZrO 2 + SiO 2 ) and the intergranular phase was characterized. In the presence of (Al 2 O 3 + SiO 2 ), the sintering is realized at 1610 deg C in H 2 . It is a liquid phase sintering. On the other end, with (ZrO 2 + SiO 2 ), the sintering is a low temperature one in oxidising atmosphere. Finally, cesium containing simulated fuels were produced with these additives. According to the effective diffusion coefficients that were measured, the additives improved the retention of cesium. We have predicted the improvement that could be hoped for in a nuclear reactor, depending on the dispersion of the intergranular additives, the temperature and the degree of oxidation of the UO 2+x . We wait for a factor of 2 for x=0 and more than 8 for x=0.05, up to 2000 deg C. (author). 148 refs., 122 figs., 34 tabs

  11. Electrostatic Focusing of Cesium Atoms in a Fountain

    Science.gov (United States)

    Gould, Harvey; Amini, Jason; Kalnins, Juris

    2004-05-01

    We have used a three element electrostatic lens, based upon the design in Ref. 1, to transversely focus a fountain of neutral cesium atoms (strong-field seeking) launched from a magneto-optic trap. Each of the three lens elements focuses in one transverse direction and defocuses in the other. Combined, the elements generate a net focusing in both transverse directions. Observations are compared with calculations. Collisional shifts in atomic fountain clocks could be significantly reduced, without loss of signal, by using electrostatic lenses and collimation. Focusing and collimation allows only atoms that will reach the detector to enter the interaction region, excluding atoms that contribute solely to collisional shifts. [1] J.G. Kalnins, G. Lambertson, and H. Gould, Rev. Sci. Instr. 73, 2557 (2002)

  12. Process for cesium decontamination and immobilization

    Science.gov (United States)

    Komarneni, Sridhar; Roy, Rustum

    1989-01-01

    Cesium can be selectively recovered from a nuclear waste solution containing cesium together with other metal ions by contact with a modified phlogopite which is a hydrated, sodium phlogopite mica. Once the cesium has entered the modified phlogopite it is fixed and can be safely stored for long periods of time.

  13. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  14. Single Lens Dual-Aperture 3D Imaging System: Color Modeling

    Science.gov (United States)

    Bae, Sam Y.; Korniski, Ronald; Ream, Allen; Fritz, Eric; Shearn, Michael

    2012-01-01

    In an effort to miniaturize a 3D imaging system, we created two viewpoints in a single objective lens camera. This was accomplished by placing a pair of Complementary Multi-band Bandpass Filters (CMBFs) in the aperture area. Two key characteristics about the CMBFs are that the passbands are staggered so only one viewpoint is opened at a time when a light band matched to that passband is illuminated, and the passbands are positioned throughout the visible spectrum, so each viewpoint can render color by taking RGB spectral images. Each viewpoint takes a different spectral image from the other viewpoint hence yielding a different color image relative to the other. This color mismatch in the two viewpoints could lead to color rivalry, where the human vision system fails to resolve two different colors. The difference will be closer if the number of passbands in a CMBF increases. (However, the number of passbands is constrained by cost and fabrication technique.) In this paper, simulation predicting the color mismatch is reported.

  15. Resolution limit of probe-forming systems with magnetic quadrupole lens triplets and quadruplets

    CERN Document Server

    Ponomarev, A G; Miroshnichenko, V I; Storizhko, V E; Sulkio-Cleff, B

    2003-01-01

    Over the past decade, in MeV ion beam microanalysis efforts to achieve a spatial resolution better than 0.1 mu m with a beam current of approx 100 pA have been connected with microprobes of new generation where the probe is formed by means of separated magnetic quadrupole lens structures . However, as was pointed out in , no dramatic improvements in spatial resolution have been produced so far. For better understanding of the situation the authors carried out theoretical studies of multiparameter sets of probe-forming systems based on separated triplets and quadruplets of magnetic quadrupole lenses. Comparisons were made between the highest current values attained at different systems for a given beam spot size. The maximum parasitic sextupole and octupole field components were found whose contributions to spot broadening are tolerable. It is shown that the use of modern electrostatic accelerators and precision magnetic quadrupole lenses makes it possible to eliminate the effect of chromatic aberrations and s...

  16. Adsorption of Radioactive Cesium to Illite-Sericite Mixed Clays

    Science.gov (United States)

    Hwang, J. H.; Choung, S.; Park, C. S.; Jeon, S.; Han, J. H.; Han, W. S.

    2016-12-01

    Once radioactive cesium is released into aquatic environments through nuclear accidents such as Chernobyl and Fukushima, it is harmful to human and ecological system for a long time (t1/2 = 30.2 years) because of its chemical toxicity and γ-radiation. Sorption mechanism is mainly applied to remove the cesium from aquatic environments. Illite is one of effective sorbent, considering economical cost for remediation. Although natural illite is typically produced as a mixture with sericite formed by phyllic alteration in hydrothermal ore deposits, the effects of illite-sericite mixed clays on cesium sorption was rarely studied. This study evaluated the sorption properties of cesium to natural illite collected at Yeongdong in Korea as the world-largest illite producing areas (termed "Yeongdong illite"). The illite samples were analyzed by XRF, XRD, FT-IR and SEM-EDX to determine mineralogy, chemical composition, and morphological characteristics, and used for batch sorption experiments. Most of "Yeongdong illite" samples predominantly consist of sericite, quartz, albite, plagioclase feldspar and with minor illite. Cesium sorption distribution coefficients (Kd,Cs) of various "Yeongdong illite" samples ranged from 500 to 4000 L/kg at low aqueous concentration (Cw 10-7 M). Considering Kd,Cs values were 400 and 6000 using reference sericite and illite materials, respectively, in this study, these results suggested that high contents of sericite significantly affect the decrease of sorption capabilities for radiocesium by natural illite (i.e., illite-sericite mixed clay).

  17. Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies.

    Science.gov (United States)

    Hura, Arjan S; Osher, Robert H

    2017-07-01

    To compare the alignment meridian generated by the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA) and the Alcon Verion Image Guided System (Alcon Laboratories, Inc., Fort Worth, TX). In this retrospective comparative evaluation of technology, intraoperative images were captured at different steps in the same surgery, allowing the comparison of the guidance lines generated by the Verion system to the parallel guidance lines generated by the Callisto Eye system. Measurements of each hemi-meridian were quantified using Adobe Photoshop 2015 CC software (Adobe Systems, San Jose, CA). The numbers of degrees separating these alignment meridians were calculated, entered into a database, and analyzed. The authors found that of 98 captured images of 16 eyes, the two technologies were identical in 0 eyes (θ 1 = θ 2 = 0), similar by 3° in 52 (53%) captured images (θ 1 ≠ θ 2 ≠ 0), and different by at least 3° in 46 (47%) captured images (θ 1 ≠ θ 2 ≠ 0). The target meridians were superimposed, the target lines were minimally separated, and the target lines were dissimilar. It was noted that some intraoperative variation occurred from measurement to measurement. Within the small group of 16 cases of routine toric lens implantation in this study, the absolute average number of degrees of misalignment between the Verion and Callisto Eye systems was 3.355 for θ 1 and 3.838 for θ 2 . On average, the intraoperative variation termed "drift" was noted to be 3.963° for θ 1 , and 4.557° for θ 2 . The authors found that small deviations were frequent when comparing two sophisticated technologies. Although deviations greater than 3° occurred in less than 47% of captured images from 16 eyes, smaller but significant variations of less than 3° occurred in 53% of captured images from 16 eyes. It was rare to identify a large deviation. However, the authors identified "drift" in the same eye when measurements were taken at different times. The results indicate that the two

  18. Transport and accumulation of cesium-137 and mercury in the Clinch River and Watts Bar Reservoir system

    International Nuclear Information System (INIS)

    Olsen, C.R.; Larsen, I.L.; Lowry, P.D.; Moriones, C.R.; Ford, C.J.; Dearstone, K.C.; Turner, R.R.; Kimmel, B.L.; Brandt, C.C.

    1992-06-01

    Operations and waste disposal activities at the Oak Ridge Y-12 Plant, the Oak Ridge National Laboratory (ORNL), and the Oak Ridge K-25 Site (formerly the Oak Ridge Gaseous Diffusion Plant) on the US Department of Energy (DOE) Oak Ridge Reservation (ORR) have introduced a variety of airborne, liquid, and solid wastes into the surrounding environment. Some of these wastes may affect off-site areas by entering local streams, which ultimately drain into the Clinch and Tennessee river system. Previously reported concentrations of radionuclides, metals and organic compounds in water, sediment, and biota of the Clinch River and Watts Bar Reservoir suggest the presence of a variety of contaminants of possible concern to the protection of human health and the environment. The work reported here represents part of the initial scoping phase for the Clinch River RCRA Facility Investigation. In this work, the distribution of 137 Cs is used to identify contaminant accumulation patterns and potential problem, or ''hot-spot,'' areas with regard to environmental hazard or human health. Radiocesium was chosen for this scoping effort because (1) its history of release into the Clinch River is reasonably well documented, (2) it is easy and inexpensive to measure by gamma spectrometry, and (3) it is rapidly sorbed to particulate matter and thus serves as a cost-effective tracer for identifying the transport and accumulation patterns of many other particle-reactive contaminants, such as mercury (Hg), lead (Pb), and plutonium (Pu), and polychlorinated biphenyls (PCBs)

  19. Design and Optimization of Fresnel Lens for High Concentration Photovoltaic System

    Directory of Open Access Journals (Sweden)

    Lei Jing

    2014-01-01

    Full Text Available A practical optimization design is proposed, in which the solar direct light spectrum and multijunction cell response range are taken into account in combination, particularly for the Fresnel concentrators with a high concentration and a small aspect ratio. In addition, the change of refractive index due to temperature variation in outdoor operation conditions is also considered in the design stage. The calculation results show that this novel Fresnel lens achieves an enhancement of energy efficiency of about 10% compared with conventional Fresnel lens for a given solar spectrum, solar cell response, and corrected sunshine hours of different ambient temperature intervals.

  20. Decorporation of cesium-137; Decorporation du cesium-137

    Energy Technology Data Exchange (ETDEWEB)

    Le Fleche, Ph.; Destombe, C.; Grasseau, A.; Mathieu, J.; Chancerelle, Y.; Mestries, J.C. [GMR, Direction des Recherches, Etudes et Techniques, 94 - Arcueil (France)

    1997-12-31

    Cesium radio-isotopes, especially cesium-137 ({sup 137}Cs) are among the radionuclides of main importance produced by a fission reaction in reactor or a nuclear weapon explosion. In the environment, {sup 137}Cs is a major contaminant which can cause severe {beta}, {gamma}irradiations and contaminations. {sup 137}Cs is distributed widely and relatively uniformly throughout the body with the highest concentration in skeletal muscles. A treatment becomes difficult afterwards. The purposes of this report are Firstly to compare the Prussian blue verses cobalt and potassium ferrocyanide (D.I. blue) efficiency for the {sup 137}Cs decorporation and secondly to assess a chronological treatment with D.I. blue. (author)

  1. Unique rod lens/video system designed to observe flow conditions in emergency core coolant loops of pressurized water reactors

    International Nuclear Information System (INIS)

    Carter, G.W.

    1979-01-01

    Techniques and equipment are described which are used for video recordings of the single- and two-phase fluid flow tests conducted with the PKL Spool Piece Measurement System designed by Lawrence Livermore Laboratory and EG and G Inc. The instrumented spool piece provides valuable information on what would happen in pressurized water reactor emergency coolant loops should an accident or rupture result in loss of fluid. The complete closed-circuit television video system, including rod lens, light supply, and associated spool mounting fixtures, is discussed in detail. Photographic examples of test flows taken during actual spool piece system operation are shown

  2. Eye evolution: lens and cornea as an upgrade of animal visual system

    Czech Academy of Sciences Publication Activity Database

    Jonášová, Kristýna; Kozmik, Zbyněk

    2008-01-01

    Roč. 19, č. 2 (2008), s. 71-81 ISSN 1084-9521 R&D Projects: GA AV ČR IAA500520604; GA MŠk(CZ) 1M0520 Institutional research plan: CEZ:AV0Z50520514 Keywords : eye * lens * cornea Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 4.528, year: 2008

  3. The gravitational lens candidate HE 1104-1805 and the size of absorption systems

    NARCIS (Netherlands)

    Smette, A; Robertson, JG; Shaver, PA; Reimers, D; Wisotzki, L; Kohler, T; Kochanek, CS; Hewitt, JN

    1996-01-01

    We obtained 1.2 Angstrom resolution spectra over the range 3175 - 7575 Angstrom for the two components of the gravitational lens candidate HE 1104-1805 (z = 2.31, m(B) = 16.7 and 18.6, separation = 3.0 arcsec; cf. Wisotzki et al. 1993), with the aim of setting limits on the sizes of the clouds

  4. CNN-coupled Humanoid Panoramic Annular Lens (PAL)-Optical System for Military Applications (Feasibility Study)

    National Research Council Canada - National Science Library

    Greguss, Pal

    2002-01-01

    ...) and the CNN chip for a few military applications. A polar beam splitter will be placed immediately after the relay lens to obtain two image planes, one will be used by the existing 64X64 CNN-UM focal plane array processor chip...

  5. Cesium-137, a drama recounted

    International Nuclear Information System (INIS)

    Vieira, Suzane de Alencar

    2013-01-01

    The radiological accident with Cesium-137, which started on Goiania in 1987, did not stop with the end of radiological contamination and continues in a judicial, scientific and narrative process of identification and recognition of new victims. The drama occupies a central place on the dynamics of radiological event, as it extends its limits, inflects its intensity and updates the event. As a narrative of the event, the ethnography incorporates and brings up to date the drama as an analysis landmark and the description of the theme as it is absorbed by a dramatic process. Cesium-137, a drama recounted is a textual experimentation based on real events and characters picked out from statements reported in various narratives about the radiological accident. (author)

  6. Accumulation and mobility of cesium in roots of tulip popular seedlings

    International Nuclear Information System (INIS)

    Cox, T.L.

    1975-01-01

    Tulip poplar, Liriodendron tulipifera L., seedlings were stem-well tagged with cesium, periodically harvested, and separated into root and shoot compartments to determine seasonal cesium distributions in different root-diameter classes and to delineate element pathways to forest soils. The cesium concentration (μCi/g) in roots less than 0.1 cm in diameter averaged 1.5 and 3.0 times greater than in roots in the 0.5- to 0.1-cm- and 1.0- to 0.5-cm-diameter classes, respectively. Roots contained 24 percent of the seedling pool of cesium in 1 week and about 40 percent in 7 weeks after inoculation. Sixty-five percent of the seedling content was in the root system 8 months after tagging. On an annual basis, roots of the less than 0.5-cm-diameter classes contained an average of 36 percent of the seedling pool (root and shoot) and 72 percent of the root pool of cesium. This is important because small roots constituted a considerable portion of the annual turnover in these root systems. Soil content of cesium (3.37 μCi) at the termination of the study and analysis of treatment effects (aboveground inputs to soil allowed or not allowed) indicated that root processes contributed twice as much cesium to the soil during the study period as the combined aboveground processes contributed

  7. Extraction of radioactive cesium from tea leaves

    International Nuclear Information System (INIS)

    Yano, Yukiko; Kubo, M. Kenya; Higaki, Shogo; Hirota, Masahiro; Nomura, Kiyoshi

    2011-01-01

    Radioactive contamination of foodstuffs attributed to the Fukushima Daiichi nuclear disaster has become a social problem. This study investigated the extraction of radioactive cesium from the contaminated leaves to the tea. The green tea was brewed twice reusing the same leaves to study the difference in extraction of cesium between the first and second brew. Moreover, the extraction of cesium was studied in correlation to brewing time. The concentration of radioactive cesium was determined with gamma spectrometry, and the concentration of caffeine was determined with absorption spectrometry. About 40% of cesium was extracted from leaves in the first brew, and about 80% was extracted in the second brew. The extraction of cesium increased over time, and it reached about 80% after 10 minutes brew. The ratio of radioactive cesium to caffeine decreased linearly over time. This study revealed that the extraction of cesium was higher for the second brew, and a rapid increase in extraction was seen as the tea was brewed for 6 minutes and more. Therefore, the first brew of green tea, which was brewed within 5 minutes, contained the least extraction of radioactive cesium from the contaminated leaves. (author)

  8. Absolute coverage of the saturated cesium silicon interfaces

    Science.gov (United States)

    Sherman, William Benjamin

    Metal/semiconductor interfaces are of great interest for a variety of reasons. They shed light on surface metal/semiconductor transitions, and they form Schottky barriers, which are of scientific as well as significant technological importance (primarily for the production of high speed, low-power logic circuitry). The cesium/silicon interfaces are of particular interest since the oxide forms a Negative Electron Affinity state. Cesium does not mix with the bulk silicon, so the interface is very abrupt, and the electronic structure of cesium is easier to understand than that of the transition metals. Further, cesium (like other alkali metals at room temperature) forms a single atomic layer on the various silicon faces and then the coverage saturates (i.e. atoms stop sticking to the surface). This makes the cesium/silicon interfaces ideal model systems of the metal/semiconductor interface. In spite of their importance, the detailed structures of the cesium saturated silicon faces are still uncertain. Numerous structural models have been proposed and many of them have quite different absolute coverages. Thus absolute coverage measurements can effectively distinguish between the various models. Rutherford Backscattering Spectrometry (RBS) provides an ideal measurement of absolute coverage since its results can be directly interpreted without dependence upon any structural model. A new beam line has been set up on the Laboratory for Research on the Structure of Matter's tandem accelerator. The Ultrahigh Vacuum system is equipped with an Auger Electron Spectrometer, a Low Energy Electron Diffraction system, a retarding field method work function analyzer, a cesium doser, a Medium Energy Ion Scattering two dimensional toroidal analyzer and a Rutherford Backscattering: Spectrometry (RBS) solid state ion detector. It has been used to manufacture saturated Cs/Si(100)-2 x 1 and Cs/Si(111)-7 x 7 interfaces and measure their absolute coverage via RBS. The coverage for the Si

  9. Advance in the study of removal of cesium from radioactive wastewater by inorganic ion exchangers

    International Nuclear Information System (INIS)

    Wang Songping; Wang Xiaowei; Du Zhihui

    2014-01-01

    The excellent performance in the removal of cesium from radioactive wastewater by inorganic ion exchangers has received extensive attention due to their characteristic physico-chemical features. The paper summarized research progress of removal of cesium by different inorganic ion exchangers such as silicoaluminate, salts of hetero polyacid, hexacyanoferrate, insoluble salts of acid with multivalent metals, insoluble hydrous oxides of multivalent metals and silicotitanate and reviewed several removal systems of cesium by inorganic ion exchangers which might offer China some reference in treatment and disposal of radioactive wastewater. (authors)

  10. Calibration for medium resolution off-axis electron holography using a flexible dual-lens imaging system in a JEOL ARM 200F microscope

    International Nuclear Information System (INIS)

    Cantu-Valle, Jesus; Ruiz-Zepeda, Francisco; Mendoza-Santoyo, Fernando; Jose-Yacaman, Miguel; Ponce, Arturo

    2014-01-01

    In this work the calibration of a medium resolution off-axis electron holography using a dual-lens imaging system in a JEOL ARM 200F is shown. The objective dual-lens configuration allows adjusting the field of view from 35 nm to 2.5 μm. Subsequently, the parameters used in phase shift reconstruction were calibrated considering biprism voltage versus fringe spacing (σ) and versus fringe width (W). The reliability of the transmission electron microscope performance using these parameters was achieved using gold nanoparticles of known size and adjusting the excitation voltage of the lenses. - Highlights: • We presented the off-axis electron holography calibration in dual-lens mode of a JEOL ARM 200F. • We provide optimal conditions for a wide field of views varying the objective lens excitation. • The calibration was made using Au-nanoparticles controlling fringe width, spacing and contrast. • Application of electron holography to nanoparticles is also shown

  11. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  12. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient

  13. Using a complex adaptive system lens to understand family caregiving experiences navigating the stroke rehabilitation system.

    Science.gov (United States)

    Ghazzawi, Andrea; Kuziemsky, Craig; O'Sullivan, Tracey

    2016-10-01

    Family caregivers provide the stroke survivor with social support and continuity during the transition home from a rehabilitation facility. In this exploratory study we examined family caregivers' perceptions and experiences navigating the stroke rehabilitation system. The theories of continuity of care and complex adaptive systems were integrated to examine the transition from a stroke rehabilitation facility to the patient's home. This study provides an understanding of the interacting complexities at the macro and micro levels. A convenient sample of family caregivers (n = 14) who provide care for a stroke survivor were recruited 4-12 weeks following the patient's discharge from a stroke rehabilitation facility in Ontario, Canada. Interviews were conducted with family caregivers to examine their perceptions and experiences navigating the stroke rehabilitation system. Directed and inductive content analysis and the theory of Complex Adaptive Systems were used to interpret the perceptions of family caregivers. Health system policies and procedures at the macro-level determined the types and timing of information being provided to caregivers, and impacted continuity of care and access to supports and services at the micro-level. Supports and services in the community, such as outpatient physiotherapy services, were limited or did not meet the specific needs of the stroke survivors or family caregivers. Relationships with health providers, informational support, and continuity in case management all influence the family caregiving experience and ultimately the quality of care for the stroke survivor, during the transition home from a rehabilitation facility.

  14. Kiloparsec Mass/Light Offsets in the Galaxy Pair-Lyα Emitter Lens System SDSS J1011+0143

    Science.gov (United States)

    Shu, Yiping; Bolton, Adam S.; Moustakas, Leonidas A.; Stern, Daniel; Dey, Arjun; Brownstein, Joel R.; Burles, Scott; Spinrad, Hyron

    2016-03-01

    We report the discovery of significant mass/light offsets in the strong gravitational lensing system SDSS J1011+0143. We use the high-resolution Hubble Space Telescope (HST) F555W- and F814W-band imaging and Sloan Digital Sky Survey (SDSS) spectroscopy of this system, which consists of a close galaxy pair with a projected separation of ≈ 4.2 {{kpc}} at zlens ˜ 0.331 lensing an Lyα emitter (LAE) at zsource = 2.701. Comparisons between the mass peaks inferred from lens models and light peaks from HST imaging data reveal significant spatial mass/light offsets as large as 1.72 ± 0.24 ± 0.34 kpc in both filter bands. Such large mass/light offsets, not seen in isolated field lens galaxies and relaxed galaxy groups, may be related to the interactions between the two lens galaxies. The detected mass/light offsets can potentially serve as an important test for the self-interacting dark matter model. However, other mechanisms such as dynamical friction on spatially differently distributed dark matter and stars could produce similar offsets. Detailed hydrodynamical simulations of galaxy-galaxy interactions with self-interacting dark matter could accurately quantify the effects of different mechanisms. The background LAE is found to contain three distinct star-forming knots with characteristic sizes from 116 to 438 pc. It highlights the power of strong gravitational lensing in probing the otherwise too faint and unresolved structures of distance objects below subkiloparsec or even 100 pc scales through its magnification effect. Based on observations made with the NASA/ESA Hubble Space Telescope, obtained from the Data Archive at the Space Telescope Science Institute, which is operated by AURA, Inc., under NASA contract NAS 5-26555. These observations are associated with program #10831.

  15. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  16. Decontamination of radioactive cesium in the soil

    International Nuclear Information System (INIS)

    Yanaga, Makoto; Oishi, Ayumi

    2013-01-01

    Decontamination of radioactive cesium from the agricultural soil was attempted by extraction method using potassium solution. The result of experiments using the soil artificially contaminated with 137 Cs showed that radioactive cesium was extracted by potassium solution. However, the extraction rate decreased when time after contamination passed. (author)

  17. Radiochemical determination of cesium-137 in seawater

    International Nuclear Information System (INIS)

    Cunha, I.I.L.; Munita, C.S.; Paiva, R.P.

    1990-01-01

    Seawater samples were collected from the Atlantic Ocean, in the vicinity of Ubatuba (Sao Paulo State - Brazil), acidified to pH 1 and stored in polyethylene containers. Cesium was precipitated with ammonium phospho molybdate (AMP), synthesized in our laboratory. The elements potassium and rubidium present in the seawater are also coprecipitated by AMP and adequate decontamination of the cesium is made by preparing a column by mixing Cs-137 AMP precipitate and asbestos. The interfering elements were eluted with 1.0 M ammonium nitrate solution whereas cesium was eluted with 1.0 M sodium hydroxide solution. Cesium was reprecipitated by acidifying the solution with concentrated hydrochloric acid. The overall chemical yield of cesium was of 75%. (author)

  18. Potential resistant morphotypes of Acanthamoeba castellanii expressed in multipurpose contact lens disinfection systems.

    Science.gov (United States)

    Ahearn, Donald G; Simmons, Robert B; Ward, Michael A; Stulting, R Doyle

    2012-11-01

    The free-living amoeba Acanthamoeba castellanii is a rare cause of contact lens-associated microbial keratitis. The cyst stage of this amoeba is noted for its resistance to disinfection by multipurpose contact lens solutions (MPS). This report examines and reviews the potential survival modes of A. castellanii in MPS. Trophozoites of A. castellanii (ATCC 30234) at densities from 10 to near 10 were incubated in 3 different MPS in a laminar flow hood for 24 hours at ambient temperatures. The dried films of MPS and phosphate-buffered saline (PBS) controls were examined before and after the addition of a peptone-yeast extract-glucose recovery broth (PYG) for the presence of amoeboid trophozoites and resistance stages over at least 7 days. The parallel exposure of trophozoites to MPS without evaporation or addition of PYG was similarly examined. Amoeboid trophozoites were not recovered in PYG nor were cyst-like structures observed in any MPS with near 10 densities. Progressively with 10 to 10 trophozoites, varied survival modes, particularly aggregates of trophozoites associated with cyst-like structures and occasional amoeboid forms and double-walled cysts with ostioles, became more evident. These morphotypes were most prominent after evaporation and typically first observed in the PYG. Trophozoites of A. castellanii near 10 and progressively to 10 densities are capable of expressing a variety of "short-term" survival modes in MPS, notably with the added stress of evaporation. Expression of these alternate survival modes in MPS may relate, in part, to contamination of contact lens cases and difficulties in developing standardized MPS efficacy tests.

  19. Investigations on cesium uranates and related compounds

    International Nuclear Information System (INIS)

    Egmond, A.B. van

    1976-01-01

    Crystal structures of cesium uranate are determined mainly by X-ray diffraction techniques. From phase studies it is concluded that of the Cs-U-O system, Cs 2 U 4 O 12 will play a prominent role in fuel elements of fast reactors due to fission product-fuel reactions causing swelling of the fuel and fuel-element failure. Crystal structures and lattice parameters are determined from Cs 2 U 4 O 12 , Cs 2 U 4 O 13 , Cs 2 U 5 O 16 , Cs 4 U 5 O 17 , Cs 2 U 7 O 22 , Cs 2 U 15 O 46 , Cs 2 UO 4 and Cs 2 U 2 O 7 . Finally some crystal structures of potassium and rubidium uranates are measured and a comparison of all available data on alkali uranates is made

  20. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

    International Nuclear Information System (INIS)

    Deng Hua; Kennedy, Christopher W; Armour, Elwood; Tryggestad, Erik; Ford, Eric; McNutt, Todd; Jiang Licai; Wong, John

    2007-01-01

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min -1 at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of ±5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD

  1. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

    Energy Technology Data Exchange (ETDEWEB)

    Deng Hua [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Kennedy, Christopher W [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Armour, Elwood [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Tryggestad, Erik [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Ford, Eric [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); McNutt, Todd [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Jiang Licai [OSMIC Inc., 1900 Taylor Rd., Auburn Hills, MI (United States); Wong, John [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States)

    2007-05-21

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min{sup -1} at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of {+-}5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.

  2. Off-axis electron holography with a dual-lens imaging system and its usefulness in 2-D potential mapping of semiconductor devices.

    Science.gov (United States)

    Wang, Y Y; Kawasaki, M; Bruley, J; Gribelyuk, M; Domenicucci, A; Gaudiello, J

    2004-11-01

    A variable magnification electron holography, applicable for two-dimensional (2-D) potential mapping of semiconductor devices, employing a dual-lens imaging system is described. Imaging operation consists of a virtual image formed by the objective lens (OL) and a real image formed in a fixed imaging plane by the objective minilens. Wide variations in field of view (100-900 nm) and fringe spacing (0.7-6 nm) were obtained using a fixed biprism voltage by varying the total magnification of the dual OL system. The dual-lens system allows fringe width and spacing relative to the object to be varied roughly independently from the fringe contrast, resulting in enhanced resolution and sensitivity. The achievable fringe width and spacing cover the targets needed for devices in the semiconductor technology road map from the 350 to 45 nm node. Two-D potential maps for CMOS devices with 220 and 70 nm gate lengths were obtained.

  3. Intense nonrelativistic cesium ion beam

    International Nuclear Information System (INIS)

    Lampel, M.C.

    1984-01-01

    The Heavy Ion Fusion group at Lawrence Berkeley Laboratory has constructed the One Ampere Cesium injector as a proof of principle source to supply an induction linac with a high charge density and high brightness ion beam. This is studied here. An electron beam probe was developed as the major diagnostic tool for characterizing ion beam space charge. Electron beam probe data inversion is accomplished with the EBEAM code and a parametrically adjusted model radial charge distribution. The longitudinal charge distribution was not derived, although it is possible to do so. The radial charge distribution that is derived reveals an unexpected halo of trapped electrons surrounding the ion beam. A charge fluid theory of the effect of finite electron temperature on the focusing of neutralized ion beams (Nucl Fus. 21, 529(1981)) is applied to the problem of the cesium beam final focus at the end of the injector. It is shown that the theory's predictions and assumptions are consistent with the experimental data, and that it accounts for the observed ion beam radius of approx.5 cm and the electron halo, including the determination of an electron Debye length of approx.10 cm

  4. Multiphoton ionization of atomic cesium

    International Nuclear Information System (INIS)

    Compton, R.N.; Klots, C.E.; Stockdale, J.A.D.; Cooper, C.D.

    1984-01-01

    We describe experimental studies of resonantly enhanced multi-photon ionization (MPI) of cesium atoms in the presence and absence of an external electric field. In the zero-field studies, photo-electron angular distributions for one- and two-photon resonantly enhanced MPI are compared with the theory of Tang and Lambropoulos. Deviations of experiment from theory are attributed to hyperfine coupling effects in the resonant intermediate state. The agreement between theory and experiment is excellent. In the absence of an external electric field, signal due to two-photon resonant three-photon ionization of cesium via np states is undetectable. Application of an electric field mixes nearby nd and ns levels, thereby inducing excitation and subsequent ionization. Signal due to two-photon excitation of ns levels in field-free experiments is weak due to their small photoionization cross section. An electric field mixes nearby np levels which again allows detectable photo-ionization signal. For both ns and np states the ''field induced'' MPI signal increases as the square of the electric field for a given principal quantum number and increases rapidly with n for a given field strength

  5. Heat capacity data for selected cesium- and iodine-containing electrolytes in water at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Saluja, P.P.S.; LeBlanc, J.C.

    1985-09-01

    The results of heat capacity measurements are presented for cesium halides and cesium iodate in water at 0.6 MPa and in the temperature range 25 to 100/sup 0/C. Partial molar heat capacity functions, partial molar heat capacity were evaluated by applying Pitzer's ion-interaction model for the extrapolation of calculated apparent molal heat capacity data, phi/sub c/, to infinite dilution. The partial molar heat capacity values in water depend strongly on the cesium salt and the temperature. For all salts, the partial molar heat capacity functions show maxima in the 75 to 93/sup 0/C range. These data can be used to determine various thermodynamic properties of aqueous cesium and iodine systems at elevated temperatures. 27 refs., 7 figs., 11 tabs.

  6. Volatilization characteristics of cesium according to the waste melting method in a plasma torch melter

    International Nuclear Information System (INIS)

    Kim, T. W.; Cho, H. Z.; Park, S. C.; Park, J. K.; Shin, S. W.

    2001-01-01

    By using a batch type plasma torch melting system, melting tests of non-combustible waste were conducted. The relationship between the volatility of cesium and torch power was evaluated. The surrogates used in the tests were natural soil with 0.5 g of non-radioactive cesium (CsCl) per 1 kg of soil. The moisture content of soil was 9.5 wt%. No significant difference in retention ratio (86 ∼ 90 wt%) of cesium in molten slag was founded according to the torch power. The faster melting with high power, the more retentions of cesium into the slag was obtained. Reaching test (TCLP) results for all waste forms were low enough to meet the EPA criteria

  7. Suicide with 137 cesium

    International Nuclear Information System (INIS)

    Vasileva, B.

    1976-01-01

    A case report is presented of suicide by radiation exposure after a preceding attempt with potassium ferrocyanide. The subject, a 30-year-old nondestructive-testing technician, held with his right fingers and then placed in his left shirt pocket a metal-canned 5,3-Ci 137 Cs source. Despite appearance of signs of severe topical injury by day 3 after the incident and development of systemic toxicity symptoms with indications of affection of internal organs by day 16, medical aid was not sought until day 21 when efforts at management proved unable to prevent fatal outcome. A prominent distinguishing characteristic of this mode of suicide is that the deed's sequelae are delayed in coming into effect. Cases known to have occurred are extremely rare (only two have been described in the literature). This is likely to be related to a distinct unpopularity of radioactive materials as well as their limited availability to the general public. The subjects that did use them were radiation workers having access to such substances; being acquainted with the biological effects of radiation, they, nevertheless, have chosen this protracted and distressful way of taking their lives. (A.B.)

  8. Objective-lens-free Fiber-based Position Detection with Nanometer Resolution in a Fiber Optical Trapping System.

    Science.gov (United States)

    Ti, Chaoyang; Ho-Thanh, Minh-Tri; Wen, Qi; Liu, Yuxiang

    2017-10-13

    Position detection with high accuracy is crucial for force calibration of optical trapping systems. Most existing position detection methods require high-numerical-aperture objective lenses, which are bulky, expensive, and difficult to miniaturize. Here, we report an affordable objective-lens-free, fiber-based position detection scheme with 2 nm spatial resolution and 150 MHz bandwidth. This fiber based detection mechanism enables simultaneous trapping and force measurements in a compact fiber optical tweezers system. In addition, we achieved more reliable signal acquisition with less distortion compared with objective based position detection methods, thanks to the light guiding in optical fibers and small distance between the fiber tips and trapped particle. As a demonstration of the fiber based detection, we used the fiber optical tweezers to apply a force on a cell membrane and simultaneously measure the cellular response.

  9. Sorption of cesium on Latvian clays

    International Nuclear Information System (INIS)

    Viss, R.; Drille, M.

    2004-01-01

    Cesium is like potassium - good solubility and mobile in a ground, easily assimilate in organism expressly brawn woof. It is a problem if pollutant is a radioactive 137 Cs. We made experiments to sorption a 2M CsF solution on some Latvian clays which mainly contain hydro micas (cesium content after good elute of clays are in table). We establish, that clay treated with 25 % sulfuric acid adsorb cesium two times more that waste clay. Hereto unstuck elute Cs from clays. (author)

  10. Application of Cesium isotopes in daily life

    International Nuclear Information System (INIS)

    Jordao, B.O.; Quaresma, D.S.; Carvalho, R.J.; Peixoto, J.G.P.

    2014-01-01

    In the world of science, the desire of the scientific community to discover new chemical elements is crucial for the development of new technologies in various fields of knowledge. And the main chemical element addressed by this article is Cesium, but specifically 133 Cesium isotope and radioisotope 137 Cesium, exemplifying their physical and chemical characteristics, and their applications. This article will also show how these isotopes have provided researchers a breakthrough in the field of radiological medicine and in time and frequency metrology. (author)

  11. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  12. Demonstration of fly-ash filter for trapping volatile radioactive cesium in off-gas stream

    International Nuclear Information System (INIS)

    Chun, K. S.; Park, J. J.; Shon, J. S.; Shin, J. M.; Choi, K. W.

    2000-02-01

    The object of this study is to design and operate the fly ash filter unit for trapping cesium in the vitrification pilot process of radioactive waste in the low and medium level. It is necessary to reuse fly ash, which is a kind of waste from coal fired power plant, in trapping cesium generated from vitrification process and improving safety and removal efficiency of off gas treatment system. According to the XRD analysis on the trapping cesium compounds by the fly ash filter, the thermally stable pollucite phase was formed when the SO x or NO x was used as the carrier gas. The trapping efficiency of volatile cesium by the fly ash filter was decreased with the increase of face velocity, whereas the efficiency was increased with the increase of the reaction temperature. And also, by increasing the reaction time, the efficiency was decreased. The trapping efficiency of volatile cesium by the fly ash filter was higher than 99.5 percent under the air or NO x /air as a carrier gas, however, the efficiency was decreased to 99.0 percent under the NO x /N 2 as a carrier gas. By the way, the effect of NO x in the vitrification pilot process might be negligible due to the supply of the significant amount of oxygen. However, because using the SO x as the carrier gas the efficiency was slightly decreased to 93.5 percent, the influence of the SO x on the trapping cesium by the fly ash filter seems to be concerned in that pilot process. The fly ash filter unit was performed in the vitrification pilot process, but the trapping efficiency of cesium by that filter could not measured because analytical instruments can not detect the cesium. However, it is confirmed that the the stainless steel 310 can be used for the material of filter frame and housing and shows the corrosion resistance at high temperature (1000 deg C). (author)

  13. Demonstrating H- beam focusing using an elliptical einzel lens

    Science.gov (United States)

    Lawrie, S. R.; Faircloth, D. C.; Letchford, A. P.; Whitehead, M. O.; Wood, T.

    2017-08-01

    H- ion source research is being performed at the ISIS spallation neutron and muon facility on a dedicated Vessel for Extraction and Source Plasma Analyses (VESPA). The ion extraction and optics system presently being used on ISIS is centered on a combined-function sector dipole magnet. This traps cesium vapor escaping the ion source; mass-separates co-extracted electrons and stripped neutrals, and weak-focusses the highly asymmetric slit-shaped ion beam. Unfortunately the added drift length through the magnet under strong space-charge forces means up to 50% of the beam is collimated on the magnet. The VESPA has shown that the ISIS ion source actually produces 80 mA of beam current at standard settings, but because of magnet collimation only 55 mA is injected into the solenoid Low Energy Beam Transport (LEBT). A new purely electrostatic post-extraction system incorporating an einzel lens with an elliptical aperture is currently under test. This allows much greater flexibility of perveance and phase space matching for injection into the LEBT and Radio Frequency Quadrupole (RFQ). This paper discusses high voltage breakdown mitigation strategies and presents the first results of the novel elliptical transport system. So far, 70 mA of beam has been transported through the new system with a normalized transverse RMS emittance of 0.2 π mm mrad.

  14. Sintered wire cesium dispenser photocathode

    Science.gov (United States)

    Montgomery, Eric J; Ives, R. Lawrence; Falce, Louis R

    2014-03-04

    A photoelectric cathode has a work function lowering material such as cesium placed into an enclosure which couples a thermal energy from a heater to the work function lowering material. The enclosure directs the work function lowering material in vapor form through a low diffusion layer, through a free space layer, and through a uniform porosity layer, one side of which also forms a photoelectric cathode surface. The low diffusion layer may be formed from sintered powdered metal, such as tungsten, and the uniform porosity layer may be formed from wires which are sintered together to form pores between the wires which are continuous from the a back surface to a front surface which is also the photoelectric surface.

  15. Cesium Eluate Analytical Data Evaluation

    International Nuclear Information System (INIS)

    Pierce, R.A.

    2003-01-01

    Bechtel National Inc. (BNI) is using IBC Company's SuperLigand ion exchange resins to separate Cs and Tc from low-activity waste (LAW) solutions (IBC-1996). Cesium is removed using the SuperLig(R) 644 resin. The resin is then eluted after each use cycle with 0.5M nitric acid solution. BNI is planning to evaporate the Cs eluate solution to reduce the storage volume and recover eluate for re-use. The primary issue associated with evaporation is end point, or salt matrix solubility. To preclude formation of solids during the storage of evaporator products, an additional criteria has been set that limits the concentration of the evaporator bottoms to 80 percent of saturation at 25 degrees C. As a result, an understanding of the effects of constituent species on the bulk solubility must be developed prior to effective evaporator operations

  16. Interim report of the DOE [Department of Energy] Type B Investigation Group: Cesium-137, a systems evaluation, encapsulation to release at Radiation Sterilizers, Inc., Decatur, Georgia

    International Nuclear Information System (INIS)

    Hultgren, R.O.

    1990-07-01

    Sometime between April 28, 1988, and June 5, 1988, a 22-inch long by 2.625-inch diameter doubly encapsulated cesium-137 irradiation source began leaking in the RSI-Decatur, Georgia, irradiation facility. By November 1988 when the source was isolated, between 7 and 8 curies (0.4 grams) leaked. This source was one of 1576 produced at Hanford to isolate the highly radioactive elements of wastes stored in single-walled tanks there. The capsule was designed for long term storage in a benign controlled pool environment on the Hanford reservation. This investigation evaluates the cause of the incident, the management and administrative matters including leasing and licensing, the capable design and manufacture, and the capsule qualification process. As a result, only two post-incident activities are discussed in the report. The first is the administrative characteristics of the early incident response, and the second is the results of the evaluation to date of the failed and other capsules from the RSI facility. 11 figs., 10 tabs

  17. A Constructive Reframing of Student Roles and Systems Learning in Medical Education Using a Communities of Practice Lens.

    Science.gov (United States)

    Gonzalo, Jed D; Thompson, Britta M; Haidet, Paul; Mann, Karen; Wolpaw, Daniel R

    2017-12-01

    Health systems are in the midst of a transformation that is being driven by a variety of forces. This has important implications for medical educators because clinical practice environments play a key role in learning and professional development, and evolving health systems are beginning to demand that providers have "systems-ready" knowledge, attitudes, and skills. Such implications provide a clear mandate for medical schools to modify their goals and prepare physicians to practice flexibly within teams and effectively contribute to the improvement of health care delivery. In this context, the concepts of value-added medical education, authentic student roles, and health systems science are emerging as increasingly important. In this Article, the authors use a lens informed by communities of practice theory to explore these three concepts, examining the implications that the communities of practice theory has in the constructive reframing of educational practices-particularly common student roles and experiences-and charting future directions for medical education that better align with the needs of the health care system. The authors apply several key features of the communities of practice theory to current experiential roles for students, then propose a new approach to students' clinical experiences-value-added clinical systems learning roles-that provides students with opportunities to make meaningful contributions to patient care while learning health systems science at the patient and population level. Finally, the authors discuss implications for professional role formation and anticipated challenges to the design and implementation of value-added clinical systems learning roles.

  18. Calibration for medium resolution off-axis electron holography using a flexible dual-lens imaging system in a JEOL ARM 200F microscope.

    Science.gov (United States)

    Cantu-Valle, Jesus; Ruiz-Zepeda, Francisco; Mendoza-Santoyo, Fernando; Jose-Yacaman, Miguel; Ponce, Arturo

    2014-12-01

    In this work the calibration of a medium resolution off-axis electron holography using a dual-lens imaging system in a JEOL ARM 200F is shown. The objective dual-lens configuration allows adjusting the field of view from 35nm to 2.5μm. Subsequently, the parameters used in phase shift reconstruction were calibrated considering biprism voltage versus fringe spacing (σ) and versus fringe width (W). The reliability of the transmission electron microscope performance using these parameters was achieved using gold nanoparticles of known size and adjusting the excitation voltage of the lenses. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Propagation of flat-topped multi-Gaussian beams through a double-lens system with apertures.

    Science.gov (United States)

    Gao, Yanqi; Zhu, Baoqiang; Liu, Daizhong; Lin, Zunqi

    2009-07-20

    A general model for different apertures and flat-topped laser beams based on the multi-Gaussian function is developed. The general analytical expression for the propagation of a flat-topped beam through a general double-lens system with apertures is derived using the above model. Then, the propagation characteristics of the flat-topped beam through a spatial filter are investigated by using a simplified analytical expression. Based on the Fluence beam contrast and the Fill factor, the influences of a pinhole size on the propagation of the flat-topped multi-Gaussian beam (FMGB) through the spatial filter are illustrated. An analytical expression for the propagation of the FMGB through the spatial filter with a misaligned pinhole is presented, and the influences of the pinhole offset are evaluated.

  20. Cesium ion bombardment of metal surfaces

    International Nuclear Information System (INIS)

    Tompa, G.S.

    1986-01-01

    The steady state cesium coverage due to cesium ion bombardment of molybdenum and tungsten was studied for the incident energy range below 500 eV. When a sample is exposed to a positive ion beam, the work function decreases until steady state is reached with a total dose of less than ≅10 16 ions/cm 2 , for both tungsten and molybdenum. A steady state minimum work function surface is produced at an incident energy of ≅100 eV for molybdenum and at an incident energy of ≅45 eV for tungsten. Increasing the incident energy results in an increase in the work function corresponding to a decrease in the surface coverage of cesium. At incident energies less than that giving the minimum work function, the work function approaches that of cesium metal. At a given bombarding energy the cesium coverage of tungsten is uniformly less than that of molybdenum. Effects of hydrogen gas coadsorption were also examined. Hydrogen coadsorption does not have a large effect on the steady state work functions. The largest shifts in the work function due to the coadsorption of hydrogen occur on the samples when there is no cesium present. A theory describing the steady-state coverage was developed is used to make predictions for other materials. A simple sticking and sputtering relationship, not including implantation, cannot account for the steady state coverage. At low concentrations, cesium coverage of a target is proportional to the ratio of (1 - β)/γ where β is the reflection coefficient and γ is the sputter yield. High coverages are produced on molybdenum due to implantation and low backscattering, because molybdenum is lighter than cesium. For tungsten the high backscattering and low implantation result in low coverages

  1. Electrically switched cesium ion exchange. FY 1997 annual report

    International Nuclear Information System (INIS)

    Lilga, M.A.; Orth, R.J.; Sukamto, J.P.H.

    1997-09-01

    This paper describes the Electrically Switched Ion Exchange (ESIX) separation technology being developed as an alternative to ion exchange for removing radionuclides from high-level waste. Progress in FY 1997 for specific applications of ESIX is also outlined. The ESIX technology, which combines ion exchange and electrochemistry, is geared toward producing electroactive films that are highly selective, regenerable, and long lasting. During the process, ion uptake and elution can be controlled directly by modulating the potential of an ion exchange film that has been electrochemically deposited onto a high surface area electrode. This method adds little sodium to the waste stream and minimizes the secondary wastes associated with traditional ion exchange techniques. Development of the ESIX process is well underway for cesium removal using ferrocyanides as the electroactive films. Films having selectivity for perrhenate (a pertechnetate surrogate) over nitrate also have been deposited and tested. Based on the ferrocyanide film capacity, stability, rate of uptake, and selectivity shown during performance testing, it appears possible to retain a consistent rate of removal and elute cesium into the same elution solution over several load/unload cycles. In batch experiments, metal hexacyanoferrate films showed high selectivities for cesium in concentrated sodium solutions. Cesium uptake was unaffected by Na/Cs molar ratios of up to 2 x 10 4 , and reached equilibrium within 18 hours. During engineering design tests using 60 pores per inch, high surface area nickel electrodes, nickel ferrocyanide films displayed continued durability. losing less than 20% of their capacity after 1500 load/unload cycles. Bench-scale flow system studies showed no change in capacity or performance of the ESIX films at a flow rate up to 13 BV/h, the maximum flow rate tested, and breakthrough curves further supported once-through waste processing. 9 refs., 24 figs

  2. Example of cesium sorption database in natural minerals

    International Nuclear Information System (INIS)

    Yokoyama, Shingo; Nakata, Kotaro; Yamada, Hirohisa; Tamura, Kenji; Watanabe, Yujiro; Sato, Tsutomu; Ito, Kenichi; Hatta, Tamao

    2013-01-01

    In the database of the National Institute for Materials Science (MatNavi), the adsorption data of cesium, strontium, and iodine have been published. Among these data, the authors picked up the data of cesium adsorption against natural ores, which were measured and compiled by the authors, graphically expressed them for clarifying the overall trends, and described each mineral’s adsorption characteristics and future challenges. The partition coefficients for the following minerals are compiled: bentonite, acid clay, montmorillonite, beidellite, vermiculite, illite, mordenite, zeolite, etc. Many of the recorded data in MatNavi are the data obtained in the systems without existence of a large amount of competing ions. On the other hand, in the accumulated water at the Fukushima Daiichi Nuclear Power Station, competing ions due to seawater are contained. In the immersion liquid of incineration fly ash and the immersion liquid of plants/vegetation, too, competing ions are considered to be contained. Accumulation of adsorption data under different solution conditions are considered important. In addition, the concentrations of radioactive cesium in decontamination target are lower values by 5-7 orders, compared with the lower limit of 0.01 ppm in the existing data. In face of experiments, the influence of adsorption to containers and filters cannot be neglected. (A.O.)

  3. The SADI Personal Health Lens: A Web Browser-Based System for Identifying Personally Relevant Drug Interactions.

    Science.gov (United States)

    Vandervalk, Ben; McCarthy, E Luke; Cruz-Toledo, José; Klein, Artjom; Baker, Christopher J O; Dumontier, Michel; Wilkinson, Mark D

    2013-04-05

    The Web provides widespread access to vast quantities of health-related information that can improve quality-of-life through better understanding of personal symptoms, medical conditions, and available treatments. Unfortunately, identifying a credible and personally relevant subset of information can be a time-consuming and challenging task for users without a medical background. The objective of the Personal Health Lens system is to aid users when reading health-related webpages by providing warnings about personally relevant drug interactions. More broadly, we wish to present a prototype for a novel, generalizable approach to facilitating interactions between a patient, their practitioner(s), and the Web. We utilized a distributed, Semantic Web-based architecture for recognizing personally dangerous drugs consisting of: (1) a private, local triple store of personal health information, (2) Semantic Web services, following the Semantic Automated Discovery and Integration (SADI) design pattern, for text mining and identifying substance interactions, (3) a bookmarklet to trigger analysis of a webpage and annotate it with personalized warnings, and (4) a semantic query that acts as an abstract template of the analytical workflow to be enacted by the system. A prototype implementation of the system is provided in the form of a Java standalone executable JAR file. The JAR file bundles all components of the system: the personal health database, locally-running versions of the SADI services, and a javascript bookmarklet that triggers analysis of a webpage. In addition, the demonstration includes a hypothetical personal health profile, allowing the system to be used immediately without configuration. Usage instructions are provided. The main strength of the Personal Health Lens system is its ability to organize medical information and to present it to the user in a personalized and contextually relevant manner. While this prototype was limited to a single knowledge domain

  4. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  5. Contact lens in keratoconus

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL. PMID:23925325

  6. Measurement of cesium and mercury emissions from the vitrification of simulated high level radioactive waste

    International Nuclear Information System (INIS)

    Zamecnik, J.R.

    1992-01-01

    In the Defense Waste Processing Facility at the Savannah River Site, it is desired to measure non-radioactive cesium in the offgas system from the glass melter. From a pilot scale melter system, offgas particulate samples were taken on filter paper media and analyzed by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The ICP-MS method proved to be sufficiently sensitive to measure cesium quantities as low as 0.135 μg, with the sensitivity being limited by the background cesium present in the filter paper. This sensitivity allowed determination of cesium decontamination factors for four of the five major components of the offgas system. In addition, total particulate measurements were also made. Measurements of mercury decontamination factors were made on the same equipment; the results indicate that most of the mercury in the offgas system probably exists as elemental mercury and HgCl 2 , with some HgO and Hg 2 Cl 2 . The decontamination factors determined for cesium, total particulate, and mercury all compared favorably with the design values

  7. Exploring the effects of task shifting for HIV through a systems thinking lens: the case of Burkina Faso.

    Science.gov (United States)

    Yaya Bocoum, Fadima; Kouanda, Seni; Kouyaté, Bocar; Hounton, Sennen; Adam, Taghreed

    2013-10-22

    While the impact of task shifting on quality of care and clinical outcomes has been demonstrated in several studies, evidence on its impact on the health system as a whole is limited. This study has two main objectives. The first is to conceptualize the wider range of effects of task shifting through a systems thinking lens. The second is to explore these effects using task shifting for HIV in Burkina Faso as a case study. We used a case study approach, using qualitative research methods. Data sources included document reviews, reviews of available data and records, as well as interviews with key informants and health workers. In addition to the traditional measures of impact of task shifting on health outcomes, our study identified 20 possible effects of the strategy on the system as a whole. Moreover, our analysis highlighted the importance of differentiating between two types of health systems effects. The first are effects inherent to the task shifting strategy itself, such as job satisfaction or better access to health services. The second are effects due to health system barriers, for example the unavailability of medicines and supplies, generating a series of effects on the various components of the health system, e.g., staff frustration.Among the health systems effects that we found are positive, mostly unintended, effects and synergies such as increased health workers' sense of responsibility and worthiness, increased satisfaction due to using the newly acquired skills in other non-HIV tasks, as well as improved patient-provider relationships. Among the negative unintended effects are staff frustration due to lack of medicines and supplies or lack of the necessary infrastructure to be able to perform the new tasks. Our analysis highlights the importance of adopting a systems thinking approach in designing, implementing and evaluating health policies to mitigate some of the design issues or system bottle-necks that may impede their successful implementation

  8. Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system.

    Science.gov (United States)

    Sookpeng, Supawitoo; Butdee, Chitsanupong

    2017-06-01

    The study aimed to evaluate the image quality in terms of signal-to-noise ratio (SNR) and dose to the lens of the eye and the other nearby organs from the CT brain scan using an automatic tube current modulation (ATCM) system with or without CT gantry tilt is needed. An anthropomorphic phantom was scanned with different settings including use of different ATCM, fixed tube current time product (mAs) settings and degree angles of gantry tilt. Gafchromic film XR-QA2 was used to measure absorbed dose of the organs. Relative doses and SNR for the various scan settings were compared with the reference setting of the fixed 330 mAs. Average absorbed dose for the lens of the eyes varied from 8.7 to 21.7 mGy. The use of the ATCM system with the gantry tilt resulted in up to 60% decrease in the dose to the lens of the eye. SNR significantly decreased while tilting the gantry using the fixed mAs techniques, compared to that of the reference setting. However, there were no statistical significant differences for SNRs between the reference setting and all ATCM settings. Compared to the reference setting of the fixed effective mAs, using the ATCM system and appropriate tilting, the gantry resulted in a substantial decrease in the dose to the lens of the eye while preserving signal-to-noise ratio. CT brain examination should be carefully controlled to optimize dose for lens of the eye and image quality of the examination.

  9. [Acanthamoeba isolation from contact lens solution of contact lens wearers without keratitis].

    Science.gov (United States)

    Watanabe, R; Ishibashi, Y; Hommura, S; Ishii, K

    1994-05-01

    Acanthamoeba keratitis seems to be associated with wearing contact lenses. As controls, we surveyed contact lens wearers without keratitis. Contact lens solutions of 93 persons were examined in order to identify risk factors for contamination by Acanthamoeba. Therefore, the contact lens disinfection system and storage schedules were studied in each case. Acanthamoeba organisms were isolated from 4 specimens (4.3%). The incidence of Acanthamoeba was higher in specimens of soft contact lens solution than in those of hard contact lens solution, and all the Acanthamoeba positive cases had been using tap water.

  10. Radioactive cesium in Finnish mushrooms; Radioaktiivinen cesium Suomen ruokasienissae

    Energy Technology Data Exchange (ETDEWEB)

    Kostiainen, E.; Ylipieti, J.

    2010-02-15

    Surveillance of radioactive cesium in Finnish mushrooms was started in 1986 at STUK. Results of the surveillance programs carried out in Lapland and other parts of Finland are given in this report. More than 2000 samples of edible mushrooms have been analysed during 1986-2008. The 137Cs detected in the mushrooms mainly originates from the 137Cs deposition due to the accident at the Chernobyl nuclear power plant in 1986. The 137Cs concentrations of mushrooms in the end of 1970s and in the beginning of 1980s varied from some ten to two hundred becquerels per kilogram originating from the nuclear weapon test period. The uneven division of the Chernobyl fallout is seen in the areal variation of 137Cs concentrations of mushrooms, the 137Cs concentrations being about tenfold in the areas with the highest deposition compared to those where the deposition was lowest. After the Chernobyl accident the maximum values in the 137Cs concentrations were reached during 1987-88 among most species of mushrooms. The 137Cs concentrations have decreased slowly, being in 2008 about 40 per cent of the maximum values. The 137Cs concentrations may be tenfold in the mushroom species with high uptake of cesium (Rozites caperatus, Hygrophorus camarophyllus, Lactarius trivialis) compared to the species with low uptake (Albatrellus ovinus, Leccinum sp.) picked in the same area. The 137Cs contents in certain species of commercial mushrooms in Finland still exceed the maximum permitted level, 600 Bq/kg, recommended to be respected when placing wild game, wild berries, wild mushrooms and lake fish on the market (Commission recommendation 2003/274/Euratom). Therefore, the 137Cs concentrations of mushrooms should be measured before placing them on the market in the areas of the highest 137Cs deposition, except for Albatrellus ovinus, Boletus sp. and Cantharellus cibarius. The 137Cs concentrations of common commercial mushroom species, Cantharellus tubaeformis and Craterellus cornucopioides often

  11. Separation of cesium from aqueous solutions using alkylated tetraaryl borates

    International Nuclear Information System (INIS)

    Feldmaier, F.

    1991-01-01

    The water solubility of cesium tetraaryl borates was lowered by introducing hydrophobic aliphatic side chains into corresponding acid-resistant fluorosubstituted tetraaryl borates. This improved cesium spearability both in precipitation and in extraction from aqueous solutions. (orig.) [de

  12. Preparation and characterization of cesium-137 aluminosilicate pellets for radioactive source applications

    International Nuclear Information System (INIS)

    Schultz, F.J.; Tompkins, J.A.; Haff, K.W.; Case, F.N.

    1981-07-01

    Twenty-seven fully loaded 137 Cs aluminosilicate pellets were fabricated in a hot cell by the vacuum hot pressing of a cesium carbonate/montmorillonite clay mixture at 1500 0 C and 570 psig. Four pellets were selected for characterization studies which included calorimetric measurements, metallography, scanning electron microscope and electron backscattering (SEM-BSE), electron microprobe, x-ray diffraction, and cesium ion leachability measurements. Each test pellet contained 437 to 450 curies of 137 Cs as determined by calorimetric measurements. Metallographic examinations revealed a two-phase system: a primary, granular, gray matrix phase containing large and small pores and small pore agglomerations, and a secondary fused phase interspersed throughout the gray matrix. SEM-BSE analyses showed that cesium and silicon were uniformly distributed throughout both phases of the pellet. This indicated that the cesium-silicon-clay reaction went to completion. Aluminum homogeneity was unconfirmed due to the high background noise associated with the inherent radioactivity of the test specimens. X-ray diffraction analyses of both radioactive and non-radioactive aluminosilicate pellets confirmed the crystal lattice structure to be pollucite. Cesium ion quasistatic leachability measurements determined the leach rates of fully loaded 137 Cs sectioned pollucite pellets to date to be 4.61 to 34.4 x 10 -10 kg m -2 s -1 , while static leach tests performed on unsectioned fully loaded pellets showed the leach rates of the cesium ion to date to be 2.25 to 3.41 x 10 -12 kg m -2 s -1 . The cesium ion diffusion coefficients through the pollucite pellet were calculated using Fick's first and second laws of diffusion. The diffusion coefficients calculated for three tracer level 137 Cs aluminosilicate pellets were 1.29 x 10 -16 m 2 s -1 , 6.88 x 10 -17 m 2 s -1 , and 1.35 x 10 -17 m 2 s -1 , respectively

  13. The Impact of Lens Opacity on SD-OCT Retinal Nerve Fiber Layer and Bruch's Membrane Opening Measurements Using the Anatomical Positioning System (APS).

    Science.gov (United States)

    Mauschitz, Matthias M; Roth, Felix; Holz, Frank G; Breteler, Monique M B; Finger, Robert P

    2017-05-01

    To evaluate the impact of lens opacity on retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening (BMO) measurements. Fifty-nine randomly selected patients without any other relevant ocular pathology undergoing elective routine cataract surgery in two specialized eye clinics were enrolled. RNFLT, BMO area, and BMO minimum rim width (BMO-MRW) were assessed with the Heidelberg Engineering Spectralis OCT using the anatomical positioning system (APS) prior to and 1 day after cataract surgery using a ring scan at different eccentricities of the disc (3.5, 4.1 and 4.7 mm). Lens opacity was quantified using densitometry based on Scheimpflug images (Oculus Pentacam AXL). RNFLT, BMO area, and BMO-MRW were virtually identical before and following removal of the cataractous lens. This held when assessed overall, within the six sectors for the 3.5-mm scan, or at any other eccentricity. Baseline RNFLT was not associated with lens opacity. Using the APS, RNFLT remained unchanged following cataract surgery, contrary to results reported by previous studies. Our results imply that the APS may have contributed to more precise spectral-domain optical coherence measurements, minimizing the influence of cataract on RNFLT and BMO assessments in our cohort.

  14. Eye lens dose correlations with personal dose equivalent and patient exposure in paediatric interventional cardiology performed with a fluoroscopic biplane system.

    Science.gov (United States)

    Alejo, L; Koren, C; Corredoira, E; Sánchez, F; Bayón, J; Serrada, A; Guibelalde, E

    2017-04-01

    To analyse the correlations between the eye lens dose estimates performed with dosimeters placed next to the eyes of paediatric interventional cardiologists working with a biplane system, the personal dose equivalent measured on the thorax and the patient dose. The eye lens dose was estimated in terms of H p (0.07) on a monthly basis, placing optically stimulated luminescence dosimeters (OSLDs) on goggles. The H p (0.07) personal dose equivalent was measured over aprons with whole-body OSLDs. Data on patient dose as recorded by the kerma-area product (P KA ) were collected using an automatic dose management system. The 2 paediatric cardiologists working in the facility were involved in the study, and 222 interventions in a 1-year period were evaluated. The ceiling-suspended screen was often disregarded during interventions. The annual eye lens doses estimated on goggles were 4.13±0.93 and 4.98±1.28mSv. Over the aprons, the doses obtained were 10.83±0.99 and 11.97±1.44mSv. The correlation between the goggles and the apron dose was R 2 =0.89, with a ratio of 0.38. The correlation with the patient dose was R 2 =0.40, with a ratio of 1.79μSvGy -1 cm -2 . The dose per procedure obtained over the aprons was 102±16μSv, and on goggles 40±9μSv. The eye lens dose normalized to P KA was 2.21±0.58μSvGy -1 cm -2 . Measurements of personal dose equivalent over the paediatric cardiologist's apron are useful to estimate eye lens dose levels if no radiation protection devices are typically used. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  16. Illumination uniformity issue explored via two-stage solar concentrator system based on Fresnel lens and compound flat concentrator

    International Nuclear Information System (INIS)

    Yeh, Naichia

    2016-01-01

    This paper illustrates details about the solar radiation distribution on the target of a two-stage solar concentrator that combines the Fresnel lens (FL) and the compound flat concentrator (CFC). The paper starts with a review of some FL development milestones such as the two-stage systems and the comparisons of flat vs. curved lenses in addition to the most noteworthy FL-based solar energy application, concentration photovoltaic (CPV). Through the review of the FL based CPV and two-stage concentrators, this study leads to the development of an algorithm to explore the spectrum distribution insight on the receiver of a two-stage (FL plus CFC) solar concentration system. It established the potential for using a correctly positioned 2nd stage reflector of right dimension to selectively redirect the desired spectrum on the target area so as to enhance the concentration flux intensity and uniformity at the same time. The study also helped to chart out the approximate locations of certain spectrum segments on the FL's target area, which is useful for exploring the spectrum control mechanism via the Fresnel lenses. - Highlights: • Map out the approximate locations of spectrum segments on FL's focal area. • Use the 2nd stage reflector to selectively reflect the desired spectrum on target. • Explore the spectrum distribution insight on FL solar concentrators' target area.

  17. VizieR Online Data Catalog: LCs & spectra of SDSS J1515+1511 lens system (Shalyapin+, 2017)

    Science.gov (United States)

    Shalyapin, V. N.; Goicoechea, L. J.

    2017-09-01

    We conducted a photometric monitoring campaign of SDSS J1515+1511 from early February of 2014 to mid September of 2016, i.e., for 2.6yr with an average sampling rate of about two nights every week. All optical observations were performed with the 2.0m fully robotic Liverpool Telescope (LT) at the Roque de los Muchachos Observatory, Canary Islands (Spain). Deep long-slit spectra of SDSS J1515+1511 were obtained using the R500B and R500R grisms in the OSIRIS spectrograph on the 10.4m Gran Telescopio Canarias (GTC). We took a single 1800s exposure with the blue grism (R500B) on 2015 April 15. We also observed the lens system with the red grism (R500R) on 2015 April 16. Hence, the new data cover a wavelength range of 3570-9250Å with a resolving power of ~300-400. We observed SDSS J1515+1511 with the SPRAT long-slit spectrograph on 2015 August 16 (red grating) and 2015 August 18 (blue). We have re-observed the system on 2016 March 17 (blue). (5 data files).

  18. Cesium Salts of Phosphotungstic Acid: Comparison of Surface ...

    African Journals Online (AJOL)

    NICO

    acidity and lowest solubility in reaction media in comparison with the other cesium content salts. KEYWORDS. Polyoxometalates, cesium ... insoluble salt of HPA is cesium salt of tungstophosphoric acid,. CsxH3-xPW12O40 (CsxPW), a ... of Cs2CO3, very fine particles (precipitates) were formed to make the solution milky.

  19. Radioactive cesium in Finnish mushrooms

    International Nuclear Information System (INIS)

    Kostiainen, E.; Ylipieti, J.

    2010-02-01

    Surveillance of radioactive cesium in Finnish mushrooms was started in 1986 at STUK. Results of the surveillance programs carried out in Lapland and other parts of Finland are given in this report. More than 2000 samples of edible mushrooms have been analysed during 1986-2008. The 137 Cs detected in the mushrooms mainly originates from the 137 Cs deposition due to the accident at the Chernobyl nuclear power plant in 1986. The 137 Cs concentrations of mushrooms in the end of 1970s and in the beginning of 1980s varied from some ten to two hundred becquerels per kilogram originating from the nuclear weapon test period. The uneven division of the Chernobyl fallout is seen in the areal variation of 137 Cs concentrations of mushrooms, the 137 Cs concentrations being about tenfold in the areas with the highest deposition compared to those where the deposition was lowest. After the Chernobyl accident the maximum values in the 137 Cs concentrations were reached during 1987-88 among most species of mushrooms. The 137 Cs concentrations have decreased slowly, being in 2008 about 40 per cent of the maximum values. The 137 Cs concentrations may be tenfold in the mushroom species with high uptake of cesium (Rozites caperatus, Hygrophorus camarophyllus, Lactarius trivialis) compared to the species with low uptake (Albatrellus ovinus, Leccinum sp.) picked in the same area. The 137 Cs contents in certain species of commercial mushrooms in Finland still exceed the maximum permitted level, 600 Bq/kg, recommended to be respected when placing wild game, wild berries, wild mushrooms and lake fish on the market (Commission recommendation 2003/274/Euratom). Therefore, the 137 Cs concentrations of mushrooms should be measured before placing them on the market in the areas of the highest 137 Cs deposition, except for Albatrellus ovinus, Boletus sp. and Cantharellus cibarius. The 137 Cs concentrations of common commercial mushroom species, Cantharellus tubaeformis and Craterellus

  20. Partitioning of cesium in hydrofracture grouts

    International Nuclear Information System (INIS)

    Stinton, D.P.; McDaniel, E.W.; Weeren, H.O.

    1983-01-01

    Phase characterization of hydrofracture grouts was accomplished with the use of optical microscopy, scanning electron microscopy, x-ray diffraction, and β-γ autoradiography. A laboratory-produced sample containing 1 wt % stable cesium and an actual hydrofracture grout sheet obtained by core dirlling were examined during this work. The phases present in these samples were identified and cesium was found to be absorbed almost entirely by illite clay agglomerates. These clay agglomerates were tightly bound within the grout structure by hydrated calcium silicates. The β-γ autoradiography of the core-drilled sample verified that cesium and other radionuclides were trapped within the 20-year-old grout and had not migrated into trapped shale fragments. 14 references, 3 figures, 1 table

  1. Hanford waste encapsulation: strontium and cesium

    International Nuclear Information System (INIS)

    Jackson, R.R.

    1976-06-01

    The strontium and cesium fractions separated from high radiation level wastes at Hanford are converted to the solid strontium fluoride and cesium chloride salts, doubly encapsulated, and stored underwater in the Waste Encapsulation and Storage Facility (WESF). A capsule contains approximately 70,000 Ci of 137 Cs or 70,000 to 140,000 Ci of 90 Sr. Materials for fabrication of process equipment and capsules must withstand a combination of corrosive chemicals, high radiation dosages and frequently, elevated temperatures. The two metals selected for capsules, Hastelloy C-276 for strontium fluoride and 316-L stainless steel for cesium chloride, are adequate for prolonged containment. Additional materials studies are being done both for licensing strontium fluoride as source material and for second generation process equipment

  2. Microbial accumulation of uranium, radium, and cesium

    International Nuclear Information System (INIS)

    Strandberg, G.W.; Shumate, S.E. II; Parrott, J.R. Jr.; North, S.E.

    1981-05-01

    Diverse microbial species varied considerably in their ability to accumulate uranium, cesium, and radium. Mechanistic differences in uranium uptake by Saccharomyces cerevisiae and Pseudomonas aeruginosa were indicated. S. serevisiae exhibited a slow (hours) surface accumulation of uranium which was subject to environmental factors, while P. aeruginosa accumulated uranium rapidly (minutes) as dense intracellular deposits and did not appear to be affected by environmental parameters. Metabolism was not required for uranium uptake by either organism. Cesium and radium were concentrated to a considerably lesser extent than uranium by the several species tested

  3. Efficiency of fly ash belite cement and zeolite matrices for immobilizing cesium

    International Nuclear Information System (INIS)

    Goni, S.; Guerrero, A.; Lorenzo, M.P.

    2006-01-01

    The efficiency of innovative matrices for immobilizing cesium is presented in this work. The matrix formulation included the use of fly ash belite cement (FABC-2-W) and gismondine-type Na-P1 zeolite, both of which are synthesized from fly ash of coal combustion. The efficiency for immobilizing cesium is evaluated from the leaching test ANSI/ANS 16.1-1986 at the temperature of 40 deg. C, from which the apparent diffusion coefficient of cesium is obtained. Matrices with 100% of FABC-2-W are used as a reference. The integrity of matrices is evaluated by porosity and pore-size distribution from mercury intrusion porosimetry, X-ray diffraction and nitrogen adsorption analyses. Both matrices can be classified as good solidify systems for cesium, specially the FABC-2-W/zeolite matrix in which the replacement of 50% of belite cement by the gismondine-type Na-P1 zeolite caused a decrease of two orders of magnitude of cesium mean Effective Diffusion Coefficient (D e ) (2.8e-09 cm 2 /s versus 2.2e-07 cm 2 /s, for FABC-2-W/zeolite and FABC-2-W matrices, respectively)

  4. Modulation transfer function estimation of optical lens system by adaptive neuro-fuzzy methodology

    Science.gov (United States)

    Petković, Dalibor; Shamshirband, Shahaboddin; Pavlović, Nenad T.; Anuar, Nor Badrul; Kiah, Miss Laiha Mat

    2014-07-01

    The quantitative assessment of image quality is an important consideration in any type of imaging system. The modulation transfer function (MTF) is a graphical description of the sharpness and contrast of an imaging system or of its individual components. The MTF is also known and spatial frequency response. The MTF curve has different meanings according to the corresponding frequency. The MTF of an optical system specifies the contrast transmitted by the system as a function of image size, and is determined by the inherent optical properties of the system. In this study, the adaptive neuro-fuzzy (ANFIS) estimator is designed and adapted to estimate MTF value of the actual optical system. Neural network in ANFIS adjusts parameters of membership function in the fuzzy logic of the fuzzy inference system. The back propagation learning algorithm is used for training this network. This intelligent estimator is implemented using Matlab/Simulink and the performances are investigated. The simulation results presented in this paper show the effectiveness of the developed method.

  5. Optical tweezers and surface plasmon resonance combination system based on the high numerical aperture lens

    Science.gov (United States)

    Shan, Xuchen; Zhang, Bei; Lan, Guoqiang; Wang, Yiqiao; Liu, Shugang

    2015-11-01

    Biology and medicine sample measurement takes an important role in the microscopic optical technology. Optical tweezer has the advantage of accurate capture and non-pollution of the sample. The SPR(surface plasmon resonance) sensor has so many advantages include high sensitivity, fast measurement, less consumption of sample and label-free detection of biological sample that the SPR sensing technique has been used for surface topography, analysis of biochemical and immune, drug screening and environmental monitoring. If they combine, they will play an important role in the biological, chemical and other subjects. The system we propose use the multi-axis cage system, by using the methods of reflection and transmiss ion to improve the space utilization. The SPR system and optical tweezer were builtup and combined in one system. The cage of multi-axis system gives full play to its accuracy, simplicity and flexibility. The size of the system is 20 * 15 * 40 cm3 and thus the sample can be replaced to switch between the optical tweezers system and the SPR system in the small space. It means that we get the refractive index of the sample and control the particle in the same system. In order to control the revolving stage, get the picture and achieve the data stored automatically, we write a LabVIEW procedure. Then according to the data from the back focal plane calculate the refractive index of the sample. By changing the slide we can trap the particle as optical tweezer, which makes us measurement and trap the sample at the same time.

  6. A reflective lens: applying critical systems thinking and visual methods to ecohealth research.

    Science.gov (United States)

    Cleland, Deborah; Wyborn, Carina

    2010-12-01

    Critical systems methodology has been advocated as an effective and ethical way to engage with the uncertainty and conflicting values common to ecohealth problems. We use two contrasting case studies, coral reef management in the Philippines and national park management in Australia, to illustrate the value of critical systems approaches in exploring how people respond to environmental threats to their physical and spiritual well-being. In both cases, we used visual methods--participatory modeling and rich picturing, respectively. The critical systems methodology, with its emphasis on reflection, guided an appraisal of the research process. A discussion of these two case studies suggests that visual methods can be usefully applied within a critical systems framework to offer new insights into ecohealth issues across a diverse range of socio-political contexts. With this article, we hope to open up a conversation with other practitioners to expand the use of visual methods in integrated research.

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lens because they can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, ... Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes ...

  8. Physical Property Modeling of Concentrated Cesium Eluate Solutions, Part I - Derivation of Models

    Energy Technology Data Exchange (ETDEWEB)

    Choi, A.S.; Pierce, R. A.; Edwards, T. B.; Calloway, T. B.

    2005-09-15

    Major analytes projected to be present in the Hanford Waste Treatment Plant cesium ion-exchange eluate solutions were identified from the available analytical data collected during radioactive bench-scale runs, and a test matrix of cesium eluate solutions was designed within the bounding concentrations of those analytes. A computer model simulating the semi-batch evaporation of cesium eluate solutions was run in conjunction with a multi-electrolyte aqueous system database to calculate the physical properties of each test matrix solution concentrated to the target endpoints of 80% and 100% saturation. The calculated physical properties were analyzed statistically and fitted into mathematical expressions for the bulk solubility, density, viscosity, heat capacity and volume reduction factor as a function of temperature and concentration of each major analyte in the eluate feed. The R{sup 2} of the resulting physical property models ranged from 0.89 to 0.99.

  9. Climate impacts, climate policies, and the role of adaptation through the lens of water systems

    Science.gov (United States)

    Hejazi, M. I.

    2016-12-01

    Recognizing the critical role of water in human-Earth system interactions, most integrated assessment models are moving to incorporate water within their modeling frameworks and climate change impacts more broadly. However, none of the IA models used in generating the four representative concentration pathways (RCPs) incorporated the potential feedbacks of water limitations on other modeled systems, meaning that these assessments did not consider the joint interactions between hydrologic and human systems simultaneously adapting to and mitigating climate change. Yet, hydrologic systems could impose severe limitations on both energy and land decisions. Also, previous efforts have been limited to taking information from IA and Earth system models and passing that information to global water management and hydrologic models with the implicit assumption that all unmet water demands are taken from non-renewable water resources, generally fossil groundwater. However, extracting and depleting water resources (e.g., aquifers) could have drastic impacts on both energy and land use systems and the ability to mitigate climate change. In this study, we use the Global Change Assessment Model (GCAM), where interactions between population, economic growth, energy, land and water resources interact simultaneously in a dynamically evolving system, to investigate: 1) how water scarcity affects energy and land use decisions as well as mitigation policies, 2) the effects of climate change impacts on the food-energy-water nexus, 3) how these impacts evolve in the context of the shared socioeconomic pathways (SSPs) with specific details on water technologies, 4) the effects of different adaptation measures and their associate investment costs, and 5) the relative contributions of climate and human systems on water scarcity. We find that previous estimates of global water withdrawal projections are overestimated, as our simulations show that it is more economical in some basins to alter

  10. A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery.

    Science.gov (United States)

    Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi

    2016-03-01

    The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.

  11. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    Science.gov (United States)

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  12. RETRACTED: Adaptive neuro-fuzzy prediction of modulation transfer function of optical lens system

    Science.gov (United States)

    Petković, Dalibor; Shamshirband, Shahaboddin; Anuar, Nor Badrul; Md Nasir, Mohd Hairul Nizam; Pavlović, Nenad T.; Akib, Shatirah

    2014-07-01

    This article has been retracted: please see Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). This article has been retracted at the request of the Editor. Sections ;1. Introduction; and ;2. Modulation transfer function;, as well as Figures 1-3, plagiarize the article published by N. Gül and M. Efe in Turk J Elec Eng & Comp Sci 18 (2010) 71 (http://journals.tubitak.gov.tr/elektrik/issues/elk-10-18-1/elk-18-1-6-0811-9.pdf). Sections ;4. Adaptive neuro-fuzzy inference system; and ;6. Conclusion; duplicate parts of the articles previously published by the corresponding author et al in ;Expert Systems with Applications; 39 (2012) 13295-13304, http://dx.doi.org/10.1016/j.eswa.2012.05.072 and ;Expert Systems with Applications; 40 (2013) 281-286, http://dx.doi.org/10.1016/j.eswa.2012.07.076. One of the conditions of submission of a paper for publication is that authors declare explicitly that the paper is not under consideration for publication elsewhere. Re-use of any data should be appropriately cited. As such this article represents an abuse of the scientific publishing system. The scientific community takes a very strong view on this matter and apologies are offered to readers of the journal that this was not detected during the submission process.

  13. Using the Lens of Social Capital to Understand Diversity in the Earth System Sciences Workforce

    Science.gov (United States)

    Callahan, Caitlin N.; Libarkin, Julie C.; McCallum, Carmen M.; Atchison, Christopher L.

    2015-01-01

    In this commentary, we argue that social capital theory, the idea that membership in a group creates opportunities to acquire valuable information and resources from other group members, is a useful framework in which to consider ways to increase diversity in the Earth System Sciences (ESS) and in the science, technology, engineering, and…

  14. Cesium and Strontium Separation Technologies Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    T. A. Todd; T. A. Todd; J. D. Law; R. S. Herbst

    2004-03-01

    Integral to the Advanced Fuel Cycle Initiative (AFCI) Program’s proposed closed nuclear fuel cycle, the fission products cesium and strontium in the dissolved spent nuclear fuel stream are to be separated and managed separately. A comprehensive literature survey is presented to identify cesium and strontium separation technologies that have the highest potential and to focus research and development efforts on these technologies. Removal of these high-heat-emitting fission products reduces the radiation fields in subsequent fuel cycle reprocessing streams and provides a significant short-term (100 yr) heat source reduction in the repository. This, along with separation of actinides, may provide a substantial future improvement in the amount of fuel that could be stored in a geologic repository. The survey and review of the candidate cesium and strontium separation technologies are presented herein. Because the AFCI program intends to manage cesium and strontium together, technologies that simultaneously separate both elements are of the greatest interest, relative to technologies that separate only one of the two elements.

  15. Sensitivity of cesium chemistry to the O/U radio in UO2+x

    International Nuclear Information System (INIS)

    McFarlane, J.; LeBlanc, J.C.; Owen, D.G.

    1995-01-01

    The effect of O/U ratio on chemical reactivity was investigated in a cesium-iodide/uranium/tungsten system at temperatures up to 2200 K. It was found that slight changes in the oxidation of the urania had a large effect on reactivity. Crushed fresh fuel samples showed little reaction with CsI; however, slightly hyperstoichiometric fuel showed considerable reaction. The tungsten participated in the reaction by removing excess oxygen from the urania, eventually leading to a cesium tungstate species that was analyzed by Fourier Transform Infrared (FTIR) and X-ray diffraction (XRD) techniques. (author)

  16. Decision document for the final disposition of cesium and strontium capsules

    Energy Technology Data Exchange (ETDEWEB)

    Claghorn, R.D., Fluor Daniel Hanford

    1997-03-01

    This report was prepared to document decisions regarding the disposition of cesium and strontium capsules. A Decision Support Board was established to consider the multiple drivers for decisions regarding disposition of cesium and strontium capsules and make decisions that form the near-term guidance for the project. The decision process included several Decision Board meetings, documented in this report, in which technical and programmatic information was presented by Tank Waste Remediation System (TWRS) technical staff and considered by the Decision Board. The process also included preparation of the decision documentation, which is presented in this report.

  17. Heat Transfer During Evaporation of Cesium From Graphite Surface in an Argon Environment

    Directory of Open Access Journals (Sweden)

    Bespala Evgeny

    2016-01-01

    Full Text Available The article focuses on discussion of problem of graphite radioactive waste formation and accumulation. It is shown that irradiated nuclear graphite being inalienable part of uranium-graphite reactor may contain fission and activation products. Much attention is given to the process of formation of radioactive cesium on the graphite element surface. It is described a process of plasma decontamination of irradiated graphite in inert argon atmosphere. Quasi-one mathematical model is offered, it describes heat transfer process in graphite-cesium-argon system. Article shows results of calculation of temperature field inside the unit cell. Authors determined the factors which influence on temperature change.

  18. Microbiomes: unifying animal and plant systems through the lens of community ecology theory

    OpenAIRE

    Christian, Natalie; Whitaker, Briana K.; Clay, Keith

    2015-01-01

    The field of microbiome research is arguably one of the fastest growing in biology. Bacteria feature prominently in studies on animal health, but fungi appear to be the more prominent functional symbionts for plants. Despite the similarities in the ecological organization and evolutionary importance of animal-bacterial and plant–fungal microbiomes, there is a general failure across disciplines to integrate the advances made in each system. Researchers studying bacterial symbionts in animals b...

  19. Microbiomes: unifying animal and plant systems through the lens of community ecology theory.

    Science.gov (United States)

    Christian, Natalie; Whitaker, Briana K; Clay, Keith

    2015-01-01

    The field of microbiome research is arguably one of the fastest growing in biology. Bacteria feature prominently in studies on animal health, but fungi appear to be the more prominent functional symbionts for plants. Despite the similarities in the ecological organization and evolutionary importance of animal-bacterial and plant-fungal microbiomes, there is a general failure across disciplines to integrate the advances made in each system. Researchers studying bacterial symbionts in animals benefit from greater access to efficient sequencing pipelines and taxonomic reference databases, perhaps due to high medical and veterinary interest. However, researchers studying plant-fungal symbionts benefit from the relative tractability of fungi under laboratory conditions and ease of cultivation. Thus each system has strengths to offer, but both suffer from the lack of a common conceptual framework. We argue that community ecology best illuminates complex species interactions across space and time. In this synthesis we compare and contrast the animal-bacterial and plant-fungal microbiomes using six core theories in community ecology (i.e., succession, community assembly, metacommunities, multi-trophic interactions, disturbance, restoration). The examples and questions raised are meant to spark discussion amongst biologists and lead to the integration of these two systems, as well as more informative, manipulatory experiments on microbiomes research.

  20. Microbiomes: unifying animal and plant systems through the lens of community ecology theory

    Directory of Open Access Journals (Sweden)

    Natalie eChristian

    2015-09-01

    Full Text Available The field of microbiome research is arguably one of the fastest growing in biology. Bacteria feature prominently in studies on animal health, but fungi appear to be the more prominent functional symbionts for plants. Despite the similarities in the ecological organization and evolutionary importance of animal-bacterial and plant-fungal microbiomes, there is a general failure across disciplines to integrate the advances made in each system. Researchers studying bacterial symbionts in animals benefit from greater access to efficient sequencing pipelines and taxonomic reference databases, perhaps due to high medical and veterinary interest. However, researchers studying plant-fungal symbionts benefit from the relative tractability of fungi under laboratory conditions and ease of cultivation. Thus each system has strengths to offer, but both suffer from the lack of a common conceptual framework. We argue that community ecology best illuminates complex species interactions across space and time. In this synthesis we compare and contrast the animal-bacterial and plant-fungal microbiomes using six core theories in community ecology (i.e., succession, community assembly, metacommunities, multi-trophic interactions, disturbance, restoration. The examples and questions raised are meant to spark discussion amongst biologists and lead to the integration of these two systems, as well as more informative, manipulatory experiments on microbiomes research.

  1. Applying a global justice lens to health systems research ethics: an initial exploration.

    Science.gov (United States)

    Pratt, Bridget; Hyder, Adnan A

    2015-03-01

    Recent scholarship has considered what, if anything, rich people owe to poor people to achieve justice in global health and the implications of this for international research. Yet this work has primarily focused on international clinical research. Health systems research is increasingly being performed in low and middle income countries and is essential to reducing global health disparities. This paper provides an initial description of the ethical issues related to priority setting, capacity-building, and the provision of post-study benefits that arise during the conduct of such research. It presents a selection of issues discussed in the health systems research literature and argues that they constitute ethical concerns based on their being inconsistent with a particular theory of global justice (the health capability paradigm). Issues identified include the fact that priority setting for health systems research at the global level is often not driven by national priorities and that capacity-building efforts frequently utilize one-size-fits-all approaches.

  2. Microbiomes: unifying animal and plant systems through the lens of community ecology theory

    Science.gov (United States)

    Christian, Natalie; Whitaker, Briana K.; Clay, Keith

    2015-01-01

    The field of microbiome research is arguably one of the fastest growing in biology. Bacteria feature prominently in studies on animal health, but fungi appear to be the more prominent functional symbionts for plants. Despite the similarities in the ecological organization and evolutionary importance of animal-bacterial and plant–fungal microbiomes, there is a general failure across disciplines to integrate the advances made in each system. Researchers studying bacterial symbionts in animals benefit from greater access to efficient sequencing pipelines and taxonomic reference databases, perhaps due to high medical and veterinary interest. However, researchers studying plant–fungal symbionts benefit from the relative tractability of fungi under laboratory conditions and ease of cultivation. Thus each system has strengths to offer, but both suffer from the lack of a common conceptual framework. We argue that community ecology best illuminates complex species interactions across space and time. In this synthesis we compare and contrast the animal-bacterial and plant–fungal microbiomes using six core theories in community ecology (i.e., succession, community assembly, metacommunities, multi-trophic interactions, disturbance, restoration). The examples and questions raised are meant to spark discussion amongst biologists and lead to the integration of these two systems, as well as more informative, manipulatory experiments on microbiomes research. PMID:26441846

  3. Cesium removal from high-pH, high-salt wastwater using crystalline silicotitanate sorbent

    Energy Technology Data Exchange (ETDEWEB)

    Walker, J.F. Jr.; Taylor, P.A.; Lee, D.D.

    1997-11-01

    Treatment and disposal options for Department of Energy (DOE) underground storage tank waste at Hanford, Savannah River, and Oak Ridge National Laboratory (ORNL) are limited by high gamma radiation fields that are produced by high concentrations of cesium in the waste. Treatment methods are needed to remove the cesium from the liquid waste and thus concentrate the cesium into high-activity, remote-handled waste forms. The treated liquids could then be processed and disposed of by more cost-effective means with less radiation exposure to workers. A full-scale demonstration of one cesium removal technology is currently being conducted at ORNL. This demonstration utilizes a modular, mobile ion-exchange system and existing facilities for the off-gas system, secondary containment, and utilities. The ion-exchange material, crystalline silicotitanate (CST), was chosen on the basis of its effectiveness in laboratory tests. The CST, which was developed through a Cooperative Research and Development Agreement between DOE and private industry, has several advantages over current organic ion-exchange technologies. These advantages include (1) the ability to remove cesium in the presence of high concentrations of potassium, (2) a high affinity for cesium in both alkaline and acidic conditions, (3) physical stability over wide alkaline and acidic ranges, and (4) the elimination of large volumes of secondary waste required for regeneration of organic ion exchangers. Approximately 100,000 L of wastewater will be processed during the demonstration. The wastewater being processed has a high salt content, about 4 M NaNO{sub 3}, and a pH of 12 to 13. This paper discusses the results of the full-scale demonstration and compares these results with data from the laboratory tests.

  4. Distribution of radioactive cesium and stable cesium in cattle kept on a highly contaminated area of Fukushima nuclear accident.

    Science.gov (United States)

    Sato, Itaru; Okada, Keiji; Sasaki, Jun; Chida, Hiroyuki; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Sato, Shusuke

    2015-07-01

    Radioactivity inspection of slaughtered cattle is generally conducted using a portion of the neck muscle; however, there is limited information about the distribution of radioactive cesium in cattle. In this study, therefore, we measured not only radioactive cesium but also stable cesium in various tissues of 19 cattle that had been kept in the area highly contaminated by the Fukushima nuclear accident. Skeletal muscles showed approximately 1.5-3.0 times higher concentration of radioactive cesium than internal organs. Radioactive cesium concentration in the tenderloin and top round was about 1.2 times as high as that in the neck muscle. The kidney showed the highest concentration of radioactive cesium among internal organs, whereas the liver was lowest. Radioactive cesium concentration in the blood was about 8% of that in the neck muscle. Characteristics of stable cesium distribution were almost the same as those of radioactive cesium. Correlation coefficient between radioactive cesium and stable cesium in tissues of individual cattle was 0.981 ± 0.012. When a suspicious level near 100 Bq/kg is detected in the neck of slaughtered cattle, re-inspection should be conducted using a different region of muscle, for example top round, to prevent marketing of beef that violates the Food Sanitation Act. © 2014 Japanese Society of Animal Science.

  5. KNOWLEDGE CONVERSION PADA PROSES PERENCANAAN PROYEK DI PT. LEN RAILWAY SYSTEM UNTUK STANDARDISASI PROSES DENGAN METODE SECI

    Directory of Open Access Journals (Sweden)

    Atikah Sayyidatu Nisaa

    2013-04-01

    Full Text Available PT LEN Railway System bergerak pada pembangunan proyek pensinyalan kereta api, namun pada proses perencanaan proyek pada perusahaan tersebut masih berupa tacit knowledge (pengalaman pekerja yang akan hilang. Oleh karena itu, diperlukan adanya konversi knowledge pekerja yang masih berbentuk tacit knowledge menjadi knowledge yang terdokumentasikan ke dalam bentuk explicit knowledge. Penelitian ini menggunakan metode SECI (Socialization, Externalization, Combination, Internalization. Pada tahap socialization dilakukan eksplorasi data kepada pelaku proyek yang bersangkutan mengenai proses bisnis suatu aktivitas maupun tacit dan explicit knowledge dari masing-masing aktivitas. Pada tahap externalization dilakukan pendokumentasian dari hasil eksplorasi data. Pada tahap combination dilakukan pemilihan best practice dengan menggunakan beberapa tools yaitu: metode Delphi, metode AHP dan pemilihan best practice menggunakan metode factor rating. Best practice yang didapatkan akan dikombinasikan dengan proses aktivitas dari PMBOK. Pada tahap internalization dilakukan penginformasian kepada pekerja mengenai best practice yang telah didapatkan dari hasil penelitian. Best practice yang terpilih dari hasil perhitungan factor rating didapatkan sebagai berikut best practice pembuatan WBS adalah proses bisnis dari responden 2 dengan nilai sebesar 8,710, untuk penentuan jadwal proyek dari responden 2 dengan nilai sebesar 8,067, untuk penentuan biaya proyek dari responden 3 sebesar 9,554, untuk pemilihan supplier dari responden 1 sebesar 8,330, untuk pembuatan desain proyek dari responden 1 sebesar 8,368 dan untuk pengadaan barang dari responden 1 dengan nilai sebesar 8,195. Kata Kunci : knowledge conversion, knowledge management, metode SECI Abstract The economic foundation movement of industrial era into the knowledge era has involved the project PT LEN Railway System which operates in the construction of the railway signaling project. This research uses SECI

  6. [Contact lens care and maintenance].

    Science.gov (United States)

    Bloise, L

    2017-04-01

    All contact lenses with replacement schedules longer than daily must be maintained. At each step of their use, the lenses may be contaminated. Contact lens solutions perform the essential functions of cleaning, decontaminating and preserving the lenses to prevent infectious problems and improve wearing comfort. Contact lens contamination essentially comes from hands, cleaning solutions, cases, water and the environment. The pathogenic microorganisms are mainly Gram-negative bacteria, fungi and amoebae. Contact lens deposits may or may not have an organic origin. Their presence increases the risk of infection because they serve as a nutrient matrix for microbes, and they are responsible for wearing discomfort. Contact lens solutions differ in their composition, their mechanism of action and the concentration of the various agents. To prescribe the best lens care system to each wearer and for each material, it is necessary to be very familiar with them. Maintenance is the main cause of discomfort with contact lenses, either through improper use, solution-material incompatibility, or a reaction of the wearer to the components. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Ontogeny and Evolution Through the Lens of the Developmental Systems Theory (DST

    Directory of Open Access Journals (Sweden)

    Vicente Dressino

    2017-09-01

    Full Text Available The Developmental Systems Theory (DST intends to make a conceptual summary that links ontogenic development to evolution. This theory’s background may be found in the works of Waddington and Bertalanffy, who provided the foundations for the canalization of development and the biological systems theory, respectively. The aim of this work is to make a preliminary conceptual analysis of DST as a theoretical framework for developmental biology in particular and for evolutionary biology in general. For that purpose, we will take into account some of the concepts and proposals that constitute this framework, and we will work with secondary data obtained from the bibliography. We conclude that: 1. DST is able to argue against the gene centrist vision about the explanations that try to justify biological and evolutionary development; 2. DST argues coherently in favor of the role of Epigenetics in ontogeny and evolution; 3. In connection to that, the role of natural selection is restricted to a secondary plane; 4. DST proposes that the nature/nurture dichotomy must be overcome; and 5. DST constitutes a possible methodological research program composed of a series of not necessarily related hypothesis, theories, and methods that may be confirmed in a relatively independent manner from the rest of the theoretical network.

  8. Clustering Algorithms in Hybrid Recommender System on MovieLens Data

    Directory of Open Access Journals (Sweden)

    Kuzelewska Urszula

    2014-08-01

    Full Text Available Decisions are taken by humans very often during professional as well as leisure activities. It is particularly evident during surfing the Internet: selecting web sites to explore, choosing needed information in search engine results or deciding which product to buy in an on-line store. Recommender systems are electronic applications, the aim of which is to support humans in this decision making process. They are widely used in many applications: adaptive WWW servers, e-learning, music and video preferences, internet stores etc. In on-line solutions, such as e-shops or libraries, the aim of recommendations is to show customers the products which they are probably interested in. As input data the following are taken: shopping basket archives, ratings of the products or servers log files.

  9. Computer simulations for intense continuous beam transport in electrostatic lens systems

    International Nuclear Information System (INIS)

    Zhao Xiaosong; Lv Jianqin

    2008-01-01

    A code LEADS based on the Lie algebraic analysis for the continuous beam dynamics with space charge effect in beam transport has been developed. The program is used for the simulations of axial-symmetric and unsymmetrical intense continuous beam in the channels including drift spaces, electrostatic lenses and DC electrostatic accelerating tubes. In order to get the accuracy required, all elements are divided into many small segments, and the electric field in the segments is regarded as uniform field, and the dividing points are treated as thin lenses. Iteration procedures are adopted in the program to obtain self-consistent solutions. The code can be used in the designs of low energy beam transport systems, electrostatic accelerators and ion implantation machines. (authors)

  10. Activity systems modeling as a theoretical lens for social exchange studies

    Directory of Open Access Journals (Sweden)

    Ernest Jones

    2016-01-01

    Full Text Available The social exchange perspective seeks to acknowledge, understand and predict the dynamics of social interactions. Empirical research involving social exchange constructs have grown to be highly technical including confirmatory factor analysis to assess construct distinctiveness and structural equation modeling to assess construct causality. Each study seemingly strives to assess how underlying social exchange theoretic constructs interrelate. Yet despite this methodological depth and resultant explanatory and predictive power, a significant number of studies report findings that, once synthesized, suggest an underlying persistent threat of conceptual or construct validity brought about by a search for epistemological parsimony. Further, it is argued that a methodological approach that embraces inherent complexity such as activity systems modeling facilitates the search for simplified models while not ignoring contextual factors.

  11. Tungsten bronze-based nuclear waste form ceramics. Part 3: The system Cs 0.3M xW 1- xO 3 for the immobilization of radio cesium

    Science.gov (United States)

    Luca, Vittorio; Drabarek, Elizabeth; Chronis, Harriet; McLeod, Terry

    2006-11-01

    Previous studies in this series have indicated that Cs- and Sr-loaded Mo-doped hexagonal tungsten bronze (MoW-HTB) oxides, either in the form of fine grained powders, or as composite granules, can be converted to leach resistant ceramics at modest temperatures in the range 600-1200 °C. In the present study it has been shown that such waste form ceramics can also be readily prepared through very simple conventional routes involving the blending of cesium nitrate with tungstic acid and other oxide components followed by heating in air. The phase chemistry resulting from the blending of these oxides has been explored. In the Cs 0.3M xW 1- xO 3 compositional system where x = Ti, Zr, Nb and Ta the solid solution limit has been found to be where x = 0.2. For all values of x between 0 and 0.2 mixed phase materials of HTB and WO 3 were obtained and Cs was found associated with HTB phases that are both rich and depleted in M element. At temperatures above about 1000 °C, phase pure HTB compounds in the space group P63/ mcm were obtained. Even when x greatly exceeds 0.2, the additional oxide content did not interfere with the formation of the HTB phase. Durability of the Cs 0.3M xW 1- xO 3 compositions as gauged by the fractional Cs loss in de-mineralized water was lowest when M = Ti and Nb, and greatest when M = Zr. From these results the durability appears intimately linked with the unit cell a-dimension which in turn varies with M cation radius.

  12. Design alternatives report for the cesium removal demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Walker, J.F. Jr.; Youngblood, E.L.

    1995-09-01

    The Cesium Removal Demonstration (CRD) project will use liquid low-level waste (LLLW) stored in the Oak Ridge National Laboratory Melton Valley Storage Tanks to demonstrate cesium removal from sodium nitrate-based supernates. This report presents the results of a conceptual design study to scope the alternatives for conducting the demonstration at ORNL. Factors considered included (1) sorbent alternatives, (2) facility alternatives, (3) process alternatives, (4) process disposal alternatives, and (5) relative cost comparisons. Recommendations included (1) that design of the CRD system move forward based on information obtained to date from tests with Savannah River Resin, (2) that the CRD system be designed so it could use crystalline silicotitanates (CST) if an engineered form of CST becomes available prior to the CRD, (3) that the system be designed without the capability for resin regeneration, (4) that the LLLW solidification facility be used for the demonstration (5) that vitrification of the loaded resins from the CRD be demonstrated at the Savannah River Site, and (6) that permanent disposal of the loaded and/or vitrified resin at the Nevada Test Site be pursued.

  13. Design alternatives report for the cesium removal demonstration

    International Nuclear Information System (INIS)

    Walker, J.F. Jr.; Youngblood, E.L.

    1995-09-01

    The Cesium Removal Demonstration (CRD) project will use liquid low-level waste (LLLW) stored in the Oak Ridge National Laboratory Melton Valley Storage Tanks to demonstrate cesium removal from sodium nitrate-based supernates. This report presents the results of a conceptual design study to scope the alternatives for conducting the demonstration at ORNL. Factors considered included (1) sorbent alternatives, (2) facility alternatives, (3) process alternatives, (4) process disposal alternatives, and (5) relative cost comparisons. Recommendations included (1) that design of the CRD system move forward based on information obtained to date from tests with Savannah River Resin, (2) that the CRD system be designed so it could use crystalline silicotitanates (CST) if an engineered form of CST becomes available prior to the CRD, (3) that the system be designed without the capability for resin regeneration, (4) that the LLLW solidification facility be used for the demonstration (5) that vitrification of the loaded resins from the CRD be demonstrated at the Savannah River Site, and (6) that permanent disposal of the loaded and/or vitrified resin at the Nevada Test Site be pursued

  14. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  15. Metabolism of 137cesium, 137barium in the rat. Therapeutics of the contamination

    International Nuclear Information System (INIS)

    Remy, J.; Philippon, A.; Lafuma, J.; Walter, C.

    1967-01-01

    The authors carry out research into the distribution kinetics, the metabolism and the excretion of 137 Cs - 137 Ba in the rat. They show that these phenomena are independent of the method of applying a single dose. The distribution tends to adopt in all cases a typical shape which remains the same depending on the body burden. Biological analysis of the state of the cesium in the biological media shows that it is transported in the free and ionised form. Considering the problem of the method of penetration of the cesium ion in the intracellular medium, and in particular by the in vivo and in vitro kinetic study of the plasma - red cell system, the authors make the assumption that an active transport of cesium occurs by the cell membrane. They thus arrive at an overall picture of the cesium distribution in the organism which is essentially characterized by a dynamic distribution equilibrium between two compartments: 99 per cent of the cesium accumulates in the intracellular pool, 1 per cent in the extracellular liquids. This latter compartment is open to the emunctories. Because, of the active transport by the cell membranes, the intracellular pool is filled rapidly but discharge is slow. This phenomenon is the limiting factor in the decrease of the body burden. From this representation, the authors deduce the reasons for the relative failure of the various therapeutic methods examined up till now by themselves or by other authors. The stimulation of the natural emunctories in the case of diuretics for example, can only improve the purification of the extracellular compartment. Now this latter contains only 1 per cent of the body burden and recharging is slow. Furthermore the methods designed to counteract or inhibit the active transport of cesium by the cell membrane are still at the present time incompatible with the survival of the cell. (authors) [fr

  16. Small-Column Cesium Ion Exchange Elution Testing of Spherical Resorcinol-Formaldehyde

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Garrett N.; Russell, Renee L.; Peterson, Reid A.

    2011-10-21

    This report summarizes the work performed to evaluate multiple, cesium loading, and elution cycles for small columns containing SRF resin using a simple, high-level waste (HLW) simulant. Cesium ion exchange loading and elution curves were generated for a nominal 5 M Na, 2.4E-05 M Cs, 0.115 M Al loading solution traced with 134Cs followed by elution with variable HNO3 (0.02, 0.07, 0.15, 0.23, and 0.28 M) containing variable CsNO3 (5.0E-09, 5.0E-08, and 5.0E-07 M) and traced with 137Cs. The ion exchange system consisted of a pump, tubing, process solutions, and a single, small ({approx}15.7 mL) bed of SRF resin with a water-jacketed column for temperature-control. The columns were loaded with approximately 250 bed volumes (BVs) of feed solution at 45 C and at 1.5 to 12 BV per hour (0.15 to 1.2 cm/min). The columns were then eluted with 29+ BVs of HNO3 processed at 25 C and at 1.4 BV/h. The two independent tracers allowed analysis of the on-column cesium interaction between the loading and elution solutions. The objective of these tests was to improve the correlation between the spent resin cesium content and cesium leached out of the resin in subsequent loading cycles (cesium leakage) to help establish acid strength and purity requirements.

  17. Experimental investigation of a multi-stage humidification-dehumidification desalination system heated directly by a cylindrical Fresnel lens solar concentrator

    International Nuclear Information System (INIS)

    Wu, Gang; Zheng, Hongfei; Ma, Xinglong; Kutlu, Cagri; Su, Yuehong

    2017-01-01

    Highlights: • A solar desalination system heated directly by curved Fresnel lens concentrator. • Desalination system is based on the humidification-dehumidification process. • Four-stage multi-effect desalination system is proposed. • Condensation latent heat and residual heat in the brine are recycled and reutilized. • The maximum yield and GOR of the unit can reach 3.4 kg/h and 2.1, respectively. - Abstract: This study demonstrates a multi-stage humidification-dehumidification (HDH) solar desalination system heated directly by a cylindrical Fresnel lens concentrator. In this novel system, the solar radiation is sent directly into desalination unit. That is to say, the solar receiver and the evaporator of the system are a whole in which the black fillers in seawater directly absorb the concentrated solar lights to heat the seawater film to produce the evaporation. The configuration and working processes of the proposed design are described in detail. In order to analyze its performance, a small solar desalination prototype unit incorporated with a cylindrical Fresnel lens concentrator was designed and built in our laboratory. Using three-stage isothermal tandem heating mode, the variation of the fresh water yield rate and the absorber temperature with time were measured experimentally and were compared with theoretical calculations. The experimental results show that the maximum yield of the unit is about 3.4 kg/h, the maximum gained output ratio (GOR) is about 2.1, when the average intensity of solar radiation is about 867 W/m 2 . This study indicates that the proposed system has the characteristics of compact structure and GOR high. It still can be improved when the design and operation are optimized further.

  18. Improvement of cesium retention in uranium dioxide by additional phases; Amelioration de la retention du cesium dans le dioxyde d`uranium au moyen de phases exogenes

    Energy Technology Data Exchange (ETDEWEB)

    Gamaury Dubois, S.

    1995-09-19

    The objective of this study is to improve the cesium retention in nuclear fuel. A bibliographic survey indicates that cesium is rapidly released from uranium dioxide in an accident condition. At temperatures higher than 1500 deg C or in oxidising conditions, our experiments show the difficulty of maintaining cesium inside simulated fuel. Two ternary systems are potentially interesting for the retention of cesium and to reduce the kinetics of release from the fuel: Cs{sub 2}O-Al{sub 2}O{sub 3}-SiO{sub 2} et Cs{sub 2}O-ZrO{sub 2}-SO{sub 2}. The compounds CsAISi{sub 2}O{sub 6} and Cs{sub 2}ZrSi{sub 6}O{sub 15} were studied from 1200 deg C to 2000 deg C by thermogravimetric analysis. The volumetric diffusion coefficients of cesium in these structures, in solid state as well as in liquid one, were measured. A fuel was sintered with (Al{sub 2}O{sub 3} + SiO{sub 2}) or (ZrO{sub 2} + SiO{sub 2}) and the intergranular phase was characterized. In the presence of (Al{sub 2}O{sub 3} + SiO{sub 2}), the sintering is realized at 1610 deg C in H{sub 2}. It is a liquid phase sintering. On the other end, with (ZrO{sub 2} + SiO{sub 2}), the sintering is a low temperature one in oxidising atmosphere. Finally, cesium containing simulated fuels were produced with these additives. According to the effective diffusion coefficients that were measured, the additives improved the retention of cesium. We have predicted the improvement that could be hoped for in a nuclear reactor, depending on the dispersion of the intergranular additives, the temperature and the degree of oxidation of the UO{sub 2+x}. We wait for a factor of 2 for x=0 and more than 8 for x=0.05, up to 2000 deg C. (author). 148 refs., 122 figs., 34 tabs.

  19. Thermal stability and expansion studies of cesium molybdates and cesium thorium molybdates

    Energy Technology Data Exchange (ETDEWEB)

    Keskar, Meera, E-mail: meerakeskar@yahoo.com; Sali, S.K.; Dahale, N.D.; Krishnan, K.; Kulkarni, N.K.; Phatak, R.; Kannan, S.

    2013-07-15

    In Cs–Mo–O system, Cs{sub 2}Mo{sub n}O{sub 3n+1} (n = 1, 3, 5 and 7) were prepared by solid state route and n = 7 was established as the highest stable analog. Differential thermal analysis of the compound Cs{sub 2}MoO{sub 4} (n = 1) in air showed a reversible phase transition followed by melting whereas compounds with n = 3, 5 and 7 did not show any phase transition up to their melting temperatures. Thermal expansion of all the molybdates were studied in vacuum using high temperature X-ray diffraction method. In quaternary Cs–Th–Mo–O system, Cs{sub 2}Th(MoO{sub 4}){sub 3} and Cs{sub 4}Th(MoO{sub 4}){sub 4} were synthesized by reacting cesium molybdate and thorium molybdate in 1:1 and 2:1 M ratios, respectively, at 873 K in air. Both compounds did not show any phase transition up to the melting and the compounds showed positive thermal expansion when heated in vacuum in the temperature range of 298–873 K.

  20. Complexation of the cesium cation with lithium ionophore VIII: extraction and DFT study

    Czech Academy of Sciences Publication Activity Database

    Makrlík, E.; Novák, Vít; Vaňura, P.; Bouř, Petr

    2013-01-01

    Roč. 298, č. 3 (2013), s. 2065-2068 ISSN 0236-5731 Institutional support: RVO:61388963 Keywords : cesium cation * lithium ionophore VIII * complexation * extraction and stability constants * water-nitrobenzene system * DFT calculations * structures Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 1.415, year: 2013

  1. Acanthamoeba, bacterial, and fungal contamination of contact lens storage cases.

    Science.gov (United States)

    Gray, T B; Cursons, R T; Sherwan, J F; Rose, P R

    1995-01-01

    BACKGROUND--Microbial corneal infection is the most serious complication of contact lens wear. Contact lens cases are a recognised potential source of pathogens associated with corneal ulcers. METHODS--This survey established the incidence of protozoal, bacterial, and fungal contact lens case contamination in 101 asymptomatic daily wear cosmetic contact lens wearers from a domiciliary contact lens practice. RESULTS--Eighty two (81%) contact lens cases were found to be contaminated, with 19 (19%) sterile. Of all contact lens cases, 78 (77%) grew bacteria, 24 (24%) fungi, and 20 (20%) protozoa. Acanthamoeba spp were isolated from eight (8%) contact lens cases. Fifty six (55%) contact lens cases yielded mixed bacterial contamination. This is the first contact lens case survey in which hydrogen peroxide disinfection was the major method of contact lens disinfection (75% of subjects) and no home made saline was used. All the contaminating organisms were shown to possess the enzyme catalase that breaks down hydrogen peroxide to oxygen and water. The polymicrobial nature of the biofilms found in many contact lens cases is illustrated electron micrographically. CONCLUSION--Based on data from this and previous studies, the authors conclude with recommendations for contact lens wearers: (1) regular scrubbing of contact lens case interior to disrupt biofilms; (2) exposure of contact lens case to very hot water (> or = 70 degrees C) will kill Acanthamoeba contaminants; (3) allow contact lens case to air dry between uses; (4) if hydrogen peroxide disinfection is preferred, use a two step system; (5) replace contact lens case regularly. Images PMID:7626578

  2. Kiloparsec Mass/Light Offsets in the Galaxy Pair-Ly$\\alpha$ Emitter Lens System SDSS\\,J1011$+$0143

    OpenAIRE

    Shu, Yiping; Bolton, Adam S.; Moustakas, Leonidas A.; Stern, Daniel; Dey, Arjun; Brownstein, Joel R.; Burles, Scott; Spinrad, Hyron

    2016-01-01

    We report the discovery of significant mass/light offsets in the strong gravitational lensing system SDSS\\,J1011$+$0143. We use the high-resolution \\textsl{Hubble Space Telescope} (\\textsl{HST}) F555W- and F814W-band imaging and Sloan Digital Sky Survey (SDSS) spectroscopy of this system, which consists of a close galaxy pair with a projected separation of $\\approx 4.2$ kpc at $z_{\\rm lens} \\sim 0.331$ lensing a Ly$\\alpha$ emitter (LAE) at $z_{\\rm source} = 2.701$. Comparisons between the mas...

  3. Thermochemical evaluation and preparation of cesium uranates

    International Nuclear Information System (INIS)

    Takano, Masahide; Minato, Kazuo; Fukuda, Kousaku; Sato, Seichi; Ohashi, Hiroshi.

    1997-03-01

    Two kinds of cesium uranates, Cs 2 UO 4 and Cs 2 U 2 O 7 , which are predicted by thermochemical estimation to be formed in irradiated oxide fuels, were prepared from U 3 O 8 and Cs 2 CO 3 for measurements of the thermal expansions and thermal conductivities. In advance of the preparation, thermochemical calculations for the formation and decomposition of these cesium uranates were performed by Gibbs free energy minimizer. The preparation temperatures for Cs 2 UO 4 and Cs 2 U 2 O 7 were determined from the results of the thermochemical calculations. The prepared samples were analyzed by X-ray diffraction, which showed that the single phases of Cs 2 UO 4 and Cs 2 U 2 O 7 were formed. Thermogravimetry and differential thermal analysis were also performed on these samples, and the decomposition temperatures were evaluated. The experimental results were in good agreement with those of the thermochemical calculations. (author)

  4. Photon interactions in a cesium beam

    International Nuclear Information System (INIS)

    Nygaard, K.J.; Jones, J.D.; Hebner, R.E. Jr

    1974-01-01

    Photoionization of excited cesium atoms in the 6 2 P3/2 - state has been studied in a triple crossed-beam experiment. A thermal beam of cesium atoms was intersected by one photon beam of wavelength 8521A that served to excite the atoms and another photon beam with wavelengths below 5060A that served to ionize the excited atoms. The resulting ions were detected with a channel electron multiplier. All background effects were discriminated against by chopping the beam of exciting radiation and by analyzing the net count rate with digital synchronous techniques. The relative cross section for photoionization fo Cs(6 2 P3/2) has been measured from threshold (5060A) to 2500A. The results fall off faster than the theoretical calculations of Weisheit and Norcross

  5. Synthesis and properties of cesium metaarsenate vanadate

    Energy Technology Data Exchange (ETDEWEB)

    Golovkin, B.G.; Slepukhin, V.K.; Volkov, V.L.

    1988-12-01

    The aim of this study was to synthesize mixed cesium vanadatoarsenate and to determine its x-ray and luminescent characteristics. Cesium metavanadate and metaarsenate were prepared from chemically pure CsNO/sub 3/ and V/sub 2/O/sub 5/ and arsenic pentoxide. The compound Cs/sub 3/(AsO/sub 3/)(VO/sub 3/)/sub 2/ was obtained by sintering stoichiometric quantities of Cs/sub 3/AsO/sub 4/ and V/sub 2/O/sub 5/ and its thermal and optical properties were studied. Upon being subjected to photoexcitation Cs/sub 3/(AsO/sub 3/)(VO/sub 3/)/sub 2/ displays strong greenish-yellow luminescence with a brightness that is 66% of that of CsVO/sub 3/ luminescence.

  6. Synthesis of double condensed cesium gallium phosphates

    Energy Technology Data Exchange (ETDEWEB)

    Chudinova, N.N.; Grunze, I.; Guzeeva, L.S.; Avaliani, M.A.

    1987-09-01

    By crystallization from melts of polyphosphoric acids there are obtained double condensed phosphates of cesium and gallium of the following compositions: Cs/sub 2/GaH/sub 3/(P/sub 2/O/sub 7/)/sub 2/, CsGaHP/sub 3/O/sub 10/, Cs/sub 3/Ga/sub 3/P/sub 12/O/sub 36/. Their x-ray characteristics are given.

  7. Transfer studies of cesium-137 in marine trophic chain

    International Nuclear Information System (INIS)

    Marchese, S.R.M.; Cunha, I.I.L.

    1994-01-01

    The both concentration factor and elimination factor of cesium-137 by the food chain: Tetraselmis gracilis, Artemia salina e Abdefduf saxatilis, were determined in laboratory conditions. The results of laboratory experiments on the uptake, accumulation and elimination of cesium-137 by the species above mentioned are described. The concentration factor determination is important to the study of cesium-137 transfer through food-chain. (author). 5 refs, 3 tabs

  8. Cesium-137 retention in irops obtained from various soils

    International Nuclear Information System (INIS)

    Gulyakin, I.V.; Yudintseva, E.V.; Gorina, L.I.

    1974-01-01

    A non-station experiment has shown that the accumulation of cesium-137 in a plant yield depends on the type of soil. The highest contents of cesium-137 were found in the yield of plants from soddy-podzolic sandy loam soils, and the lowest- in those from leached chernozem. The accumulation of radiocesium in the yield of the basic produce strongly depended on the plant species. The amount of cesium-137 differed 5- to 7-fold in different crops

  9. Structural Conditions for Collaboration and Learning in Innovation Networks: Using an Innovation System Performance Lens to Analyse Agricultural Knowledge Systems

    NARCIS (Netherlands)

    Hermans, F.; Klerkx, L.W.A.; Roep, D.

    2015-01-01

    Purpose: We investigate how the structural conditions of eight different European agricultural innovation systems can facilitate or hinder collaboration and social learning in multidisciplinary innovation networks. Methodology: We have adapted the Innovation System Failure Matrix to investigate the

  10. Cesium-137 as a radiation source

    International Nuclear Information System (INIS)

    McMullen, W.H.; Sloan, D.P.

    1985-01-01

    The U.S. Department of Energy (DOE) Byproducts Utilization Program (BUP) seeks to develop and encourage widespread commercial use of defense byproducts that are produced by DOE. Cesium-l37 is one such byproduct that is radioactive and decays with emission of gamma rays. The beneficial use of this radiation to disinfect sewage sludge or disinfest food commodities is actively being pursued by the program. The radiation produced by cesium-l37(Cs-l37) is identical in form to that produced by cobalt-60(Co-60), an isotope that is widely used in commercial applications such as medical product sterilization. The choice of isotope to use depends on several factors ranging from inherent properties of the isotopes to availability and cost. The BUP, although centrally concerned with the beneficial use of Cs-l37, by investigating and assessing the feasibility of various uses hopes to define appropriate circumstances where cesium or cobalt might best be used to accomplish specific objectives. This paper discusses some of the factors that should be considered when evaluating potential uses for isotopic sources

  11. Quantum-degenerate cesium. Atoms and molecules

    International Nuclear Information System (INIS)

    Herbig, J.

    2005-04-01

    A Bose-Einstein condensate (BEC) of cesium atoms features the possibility to control the interatomic interaction. This outstanding property results from various couplings to molecular states, which show up in a rich spectrum of Feshbach resonances at easily accessible magnetic fields. In the frame of this thesis, we create a BEC of cesium and exploit its tunability for new experiments on Cs atoms and in the creation of Cs molecules. To produce the BEC we employ a sequence of two optical traps to realize good loading conditions as well as efficient evaporation. With this strategy we were able to create the first BEC of cesium. Optimization yields more than 100000 condensed atoms. We demonstrate the tunability of the mean-field interaction in the condensate by measuring the release energy as a function of the scattering lengths. By switching the scattering length to zero, we realize a non-expanding 'frozen condensate'. We use the BEC to create ultracold Cs 2 molecules by applying a magnetic field ramp over a Feshbach resonance. We separate atoms from molecules in a Stern-Gerlach type scheme. We observe ultra-low molecular expansion energies, consistent with the presence of a macroscopic molecular matter wave. Using a novel magnetic field ramping scheme we can greatly improve the achieved conversion efficiencies. In first experiments we transfer molecules to different internal molecular states using avoided level crossings. Finally, we demonstrate trapping of molecules in a CO 2 -laser trap, which offers a prospect for a trapped molecular BEC. (author)

  12. Contact lens in keratoconus

    OpenAIRE

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  13. Lanthanide doped strontium-barium cesium halide scintillators

    Science.gov (United States)

    Bizarri, Gregory; Bourret-Courchesne, Edith; Derenzo, Stephen E.; Borade, Ramesh B.; Gundiah, Gautam; Yan, Zewu; Hanrahan, Stephen M.; Chaudhry, Anurag; Canning, Andrew

    2015-06-09

    The present invention provides for a composition comprising an inorganic scintillator comprising an optionally lanthanide-doped strontium-barium, optionally cesium, halide, useful for detecting nuclear material.

  14. Effective X-ray beam size measurements of an X-ray tube and polycapillary X-ray lens system using a scanning X-ray fluorescence method

    Energy Technology Data Exchange (ETDEWEB)

    Gherase, Mihai R., E-mail: mgherase@csufresno.edu; Vargas, Andres Felipe

    2017-03-15

    Size measurements of an X-ray beam produced by an integrated polycapillary X-ray lens (PXL) and X-ray tube system were performed by means of a scanning X-ray fluorescence (SXRF) method using three different metallic wires. The beam size was obtained by fitting the SXRF data with the analytical convolution between a Gaussian and a constant functions. For each chemical element in the wire an effective energy was calculated based on the incident X-ray spectrum and its photoelectric cross section. The proposed method can be used to measure the effective X-ray beam size in XRF microscopy studies.

  15. Improvement of Varioptic's liquid lens based on electrowetting: how to obtain a short response time and its application in the design of a high resolution iris biometric system

    Science.gov (United States)

    Burger, Benjamin; Meimon, Serge C.; Petit, Cyril; Nguyen, Minh Chau

    2015-02-01

    This communication presents the results obtained for decreasing the response time of electrowetting-based real time focus correctors (liquid lenses). In order to provide a compact iris biometric system demonstrator, we have achieved a response time at 90% of 7.5 ms for a change in focalization from 0 diopter to 10 diopter with a liquid lens having an aperture of 1.9 mm. We have used a hydrodynamic fluid reorganization model to predict the features of these fast liquid lenses and evaluated the sensivity of the response time to the different conception parameters.

  16. Americium, Cesium, and Plutonium Colloid-Facilitated Transport in a Groundwater/Bentonite/Fracture Fill Material System: Column Experiments and Model Results

    Science.gov (United States)

    Dittrich, T. M.; Boukhalfa, H.; Reimus, P. W.

    2014-12-01

    The objective of this study was to investigate and quantify the effects of desorption kinetics and colloid transport on radionuclides with different sorption affinities. We focused on quantifying transport mechanisms important for upscaling in time and distance. This will help determine the long-term fate and transport of radionuclides to aid in risk assessments. We selected a fractured/weathered granodiorite at the Grimsel Test Site (GTS) in Switzerland as a model crystalline rock repository system because the system has been thoroughly studied and field experiments involving radionuclides have already been conducted. Working on this system provides a unique opportunity to compare lab experiments with field-scale observations. Weathered fracture fill material (FFM) and bentonite used as backfill at the GTS were characterized (e.g., BET, SEM/EDS, QXRD), and batch and breakthrough column experiments were conducted. Solutions were prepared in synthetic groundwaters that matched the natural water chemistry. FFM samples were crushed, rinsed, sieved (150-355 μm), and equilibrated with synthetic groundwater. Bentonite was crushed, sodium-saturated, equilibrated with synthetic groundwater, and settled to yield a stable suspension. Suspensions were equilibrated with Am, Cs, or Pu. All experiments were conducted with Teflon®materials to limit sorption to system components. After radionuclide/colloid injections reached stability, radionuclide-free solutions were injected to observe the desorption and release behavior. Aliquots of effluent were measured for pH, colloid concentration, and total and dissolved radionuclides. Unanalyzed effluent from the first column was then injected through a second column of fresh material. The process was repeated for a third column and the results of all three breakthrough curves were modeled with a multi-site/multi-rate MATLAB code to elucidate the sorption rate coefficients and binding site densities of the bentonite colloids and

  17. Structural Conditions for Collaboration and Learning in Innovation Networks: Using an Innovation System Performance Lens to Analyse Agricultural Knowledge Systems

    Science.gov (United States)

    Hermans, Frans; Klerkx, Laurens; Roep, Dirk

    2015-01-01

    Purpose: We investigate how the structural conditions of eight different European agricultural innovation systems can facilitate or hinder collaboration and social learning in multidisciplinary innovation networks. Methodology: We have adapted the Innovation System Failure Matrix to investigate the main barriers and enablers eight countries…

  18. Dual cesium and rubidium atomic fountain with a 10-16 level accuracy and applications

    International Nuclear Information System (INIS)

    Chapelet, F.

    2008-05-01

    Atomic fountains are the most accomplished development of the atomic clocks based on the cesium atom whose hyperfine resonance defines the SI second since 1967. Today these systems are among those which realize the second with the best accuracy. We present the last developments of the cold cesium and rubidium atom dual fountain experiment at LNE-SYRTE. This unique dual setup would allow to obtain an outstanding resolution in fundamental physics tests based on atomic transition frequency comparisons. In order to enable operation with both atomic species simultaneously, we designed, tested and implemented on the fountain new collimators which combine the laser lights corresponding to each atom. By comparing our rubidium fountain to another cesium fountain over a decade, we performed a test of the stability of the fine structure constant at the level of 5 * 10 -16 per year. We carried on the work on the clock accuracy and we focused on the phase gradients effects in the interrogation cavity and on the microwave leakage. The fountain accuracy has been evaluated to 4 * 10 -16 for the cesium clock and to 5 * 10 -16 for the refurbished rubidium clock. As a powerful instrument of metrology, our fountain was implicated in many clock comparisons and contributed many times to calibrate the International Atomic Time. Furthermore, we used the fountain to perform a new test of Lorentz local invariance. (author)

  19. Assessment of commercially available ion exchange materials for cesium removal from highly alkaline wastes

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, K.P.; Kim, A.Y.; Kurath, D.E.

    1996-04-01

    Approximately 61 million gallons of nuclear waste generated in plutonium production, radionuclide removal campaigns, and research and development activities is stored on the Department of Energy`s Hanford Site, near Richland, Washington. Although the pretreatment process and disposal requirements are still being defined, most pretreatment scenarios include removal of cesium from the aqueous streams. In many cases, after cesium is removed, the dissolved salt cakes and supernates can be disposed of as LLW. Ion exchange has been a leading candidate for this separation. Ion exchange systems have the advantage of simplicity of equipment and operation and provide many theoretical stages in a small space. The organic ion exchange material Duolite{trademark} CS-100 has been selected as the baseline exchanger for conceptual design of the Initial Pretreatment Module (IPM). Use of CS-100 was chosen because it is considered a conservative, technologically feasible approach. During FY 96, final resin down-selection will occur for IPM Title 1 design. Alternate ion exchange materials for cesium exchange will be considered at that time. The purpose of this report is to conduct a search for commercially available ion exchange materials which could potentially replace CS-100. This report will provide where possible a comparison of these resin in their ability to remove low concentrations of cesium from highly alkaline solutions. Materials which show promise can be studied further, while less encouraging resins can be eliminated from consideration.

  20. Removal of cesium and strontium from low active waste solutions by zeolites

    International Nuclear Information System (INIS)

    Jain, Savita; Ramaswamy, M.; Theyyunni, T.K.

    1994-01-01

    Ion exchange, crystallographic and thermal characteristics of sodium, cesium and strontium forms of locally available synthetic zeolites have been investigated. X-ray and differential thermal analyses have confirmed that the synthetic materials AR1 and 4A belonged to the mordenite and A type families of zeolites respectively. Equilibrium uptake of cesium and strontium ions by sodium forms of zeolite was studied as a function of time, pH and sodium concentration. It was found that the rate of sorption by AR1 was higher than that by 4A. In regard to pH, distribution of nuclides on zeolites was found to pass through maxima at a pH value of around 9. Sodium ion interfered with the sorption of cesium and strontium by zeolites. However, at sodium concentration ≤ 0.01 M, distribution coefficient values for these nuclides were sufficiently high to merit consideration of these zeolites for low level waste treatment. Lab-scale column runs using 5 ml beds of materials showed that the zeolites AR1 and 4A were very effective in removing cesium and strontium nuclides respectively from large volumes (a decontamination factor of 50 for a throughput of 6000 bed volumes) of actual low level waste solutions. Thus, the zeolite system has a potential future for large scale application in the treatment of low level wastes. (author). 6 refs., 5 figs., 6 tabs

  1. Assessment of commercially available ion exchange materials for cesium removal from highly alkaline wastes

    International Nuclear Information System (INIS)

    Brooks, K.P.; Kim, A.Y.; Kurath, D.E.

    1996-04-01

    Approximately 61 million gallons of nuclear waste generated in plutonium production, radionuclide removal campaigns, and research and development activities is stored on the Department of Energy's Hanford Site, near Richland, Washington. Although the pretreatment process and disposal requirements are still being defined, most pretreatment scenarios include removal of cesium from the aqueous streams. In many cases, after cesium is removed, the dissolved salt cakes and supernates can be disposed of as LLW. Ion exchange has been a leading candidate for this separation. Ion exchange systems have the advantage of simplicity of equipment and operation and provide many theoretical stages in a small space. The organic ion exchange material Duolite trademark CS-100 has been selected as the baseline exchanger for conceptual design of the Initial Pretreatment Module (IPM). Use of CS-100 was chosen because it is considered a conservative, technologically feasible approach. During FY 96, final resin down-selection will occur for IPM Title 1 design. Alternate ion exchange materials for cesium exchange will be considered at that time. The purpose of this report is to conduct a search for commercially available ion exchange materials which could potentially replace CS-100. This report will provide where possible a comparison of these resin in their ability to remove low concentrations of cesium from highly alkaline solutions. Materials which show promise can be studied further, while less encouraging resins can be eliminated from consideration

  2. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  3. The correct lens mount lightweighting design and thermal stress OPD analysis in Cassegrain telescope

    Science.gov (United States)

    Hsu, Ming-Ying; Chan, Chia-Yen; Lin, Wei-Cheng; Chang, Shenq-Tsong; Huang, Ting-Ming

    2013-09-01

    This study is trying to evaluate different lens barrel material, caused lens stress OPD (Optical Path Different) in different temperature condition. The Cassegrain telescope's correct lens assembly are including as correct lens, lens mount, spacer, mount barrel and retainer. The lens barrel initial design is made by invar, but system mass limit is need to lightweighting to meet requirement. Therefore, the lens barrel material is tried to replace to lower density material, such as aluminum and titanium alloy. Meanwhile, the aluminum or titanium alloy material properties CTE (Coefficient of Thermal Expansion) are larger then invar. Thus, the high CTE material will introduce larger thermal stress into the optical system in different temperature condition. This article is analysis the correct lens assembly thermal stress and optical performance in different lens mount material. From above conditions, using FEM (Finite Element Method) and optical software, simulation and optimization the lens mount to achieve system mass requirement.

  4. Experimental Investigation on the Feasibility of Using a Fresnel Lens as a Solar-Energy Collection System for Enhancing On-Orbit Power Generation Performance

    Directory of Open Access Journals (Sweden)

    Tae-Yong Park

    2017-01-01

    Full Text Available Cube satellites have a limitation for generating power because of their cubic structure and extremely small size. In addition, the incidence angle between the sun and the solar panels continuously varies owing to the revolution and rotation of the satellite according to the attitude control strategy. This angle is an important parameter for determining the power generation performance of the cube satellite. In this study, we performed an experimental feasibility study that uses a Fresnel lens as a solar-energy collection system for cube satellite applications, so that the power generation efficiency can be enhanced under the worst incidence angle condition between the sun and solar panels by concentrating and redirecting solar energy onto the solar panels with a commercial Fresnel lens. To verify the effectiveness of the proposed system, we conducted a power-measurement test using a solar simulator and Fresnel lenses at various angles to the light source. In addition, we predicted the on-orbit power-generation enhancement achieved by employing the solar-energy collection system with various attitude control strategies.

  5. Sympathetic cooling in a rubidium cesium mixture: Production of ultracold cesium atoms; Sympathetisches Kuehlen in einer Rubidium-Caesium-Mischung: Erzeugung ultrakalter Caesiumatome

    Energy Technology Data Exchange (ETDEWEB)

    Haas, M.

    2007-07-01

    This thesis presents experiments for the production of ultracold rubidium cesium mixture in a magnetic trap. The long-termed aim of the experiment is the study of the interaction of few cesium atoms with a Bose-Einstein condensate of rubidium atoms. Especially by controlled variation of the cesium atom number the transition in the description of the interaction by concepts of the one-particle physics to the description by concepts of the many-particle physics shall be studied. The rubidium atoms are trapped in a magneto-optical trap (MOT) and from there reloaded into a magnetic trap. In this the rubidium atoms are stored in the state vertical stroke f=2,m{sub f}=2 right angle of the electronic ground state and evaporatively cooled by means of microwave-induced transitions into the state vertical stroke f=1,m{sub f}=1] (microwave cooling). The cesium atoms are also trppaed in a MOT and into the same magnetic trap reloaded, in which they are stored in the state vertical stroke f=4,m{sub f}=4 right angle of the electronic ground state together with rubidium. Because of the different hyperfine splitting only rubidium is evaporatively cooled, while cesium is cooled jointly sympathetically - i.e. by theramal contact via elastic collisions with rubidium atoms. The first two chapters contain a description of interatomic interactions in ultracold gases as well as a short summary of theoretical concepts in the description of Bose-Einstein condensates. The chapters 3 and 4 contain a short presentation of the methods applied in the experiment for the production of ultracold gases as well as the experimental arrangement; especially in the framework of this thesis a new coil system has been designed, which offers in view of future experiments additionally optical access for an optical trap. Additionally the fourth chapter contains an extensive description of the experimental cycle, which is applied in order to store rubidium and cesium atoms together into the magnetic trap. The

  6. Numerical studies of triplet and Russian quadruplet quadrupole lens systems with the given spot size on the target, for use in a microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Brazhnik, V.A.; Lebed, S.A.; Ponomarev, A.G.; Storizhko, V.E. [Ukrainian Academy of Sciences, Sumy (Ukraine). Applied Physics Institute; Dymnikov, A.D. [University of St Petersburg, Stary (Russian Federation). Institute of Computational Mathematics and Control Processes; Jamieson, D.N.; Legge, S.A. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1993-12-31

    In a nuclear microprobe the focusing system is an essential component which determines the beam spot size, i.e. the microprobe resolution. A small beam cross section at the target is the most important of the many conflicting requirements imposed on the beam The second most important factor is the current of the beam which at the given brightness is proportional to the phase volume (or emittance) of the beam. Existing microprobes frequently use a triplet or a Russian quadruplet as the focusing systems. This paper describes the numerical studies of some optimal quadrupole lens systems consisting of three or four lenses suitable for use in a nuclear microprobe taking into account geometrical aberrations of third order. The maximum emittance of changed particle beams for these systems has been found. It is shown how the maximum emittance depends on the spot size. 2 refs., 2 figs.

  7. Numerical studies of triplet and Russian quadruplet quadrupole lens systems with the given spot size on the target, for use in a microprobe

    International Nuclear Information System (INIS)

    Brazhnik, V.A.; Lebed, S.A.; Ponomarev, A.G.; Storizhko, V.E.; Dymnikov, A.D.; Jamieson, D.N.; Legge, S.A.

    1993-01-01

    In a nuclear microprobe the focusing system is an essential component which determines the beam spot size, i.e. the microprobe resolution. A small beam cross section at the target is the most important of the many conflicting requirements imposed on the beam The second most important factor is the current of the beam which at the given brightness is proportional to the phase volume (or emittance) of the beam. Existing microprobes frequently use a triplet or a Russian quadruplet as the focusing systems. This paper describes the numerical studies of some optimal quadrupole lens systems consisting of three or four lenses suitable for use in a nuclear microprobe taking into account geometrical aberrations of third order. The maximum emittance of changed particle beams for these systems has been found. It is shown how the maximum emittance depends on the spot size. 2 refs., 2 figs

  8. Strontium-90 and cesium-137 in powdered milk

    International Nuclear Information System (INIS)

    1977-01-01

    Japan Chemical Analysis Center has analysed the strontium-90 and cesium-137 content in powdered milk. The samples were purchased on the open market in Tokyo from the powdered milk producers. The analysis of Strontium-90 and Cesium-137 content was carried out using the method recommended by Science and Technology Agency. (author)

  9. Subjective assessment of contact lens wear by army aircrew.

    Science.gov (United States)

    Lattimore, M R; Cornum, R L

    1993-07-01

    Because 23% of Army aviators are ametropic, contact lenses have drawn increased attention as a spectacle substitute to solve system compatibility problems. From November 1988 until October 1991, a series of contact lens research protocols were conducted to develop a comprehensive database on contact lens wear in varied environments. Questionnaires were used to assess suitability and acceptability of routine contact lens wear. Responses from 202 subjects were obtained from September 1989 through September 1991. The questions explored operational and safety of flight issues of contact lens wear. Subjects overwhelmingly approved of contact lens use in all settings: 95% expressed greater combat readiness and effectiveness with contact lenses, 98% felt contact lens use (and maintenance) in the cockpit had no adverse impact on safety of flight, and 98% endorsed the routine use of contact lenses. These data highlight Army aircrew acceptance of contact lens use.

  10. Web-Based Geospatial Visualization of GPM Data with CesiumJS

    Science.gov (United States)

    Lammers, Matt

    2018-01-01

    Advancements in the capabilities of JavaScript frameworks and web browsing technology have made online visualization of large geospatial datasets such as those coming from precipitation satellites viable. These data benefit from being visualized on and above a three-dimensional surface. The open-source JavaScript framework CesiumJS (http://cesiumjs.org), developed by Analytical Graphics, Inc., leverages the WebGL protocol to do just that. This presentation will describe how CesiumJS has been used in three-dimensional visualization products developed as part of the NASA Precipitation Processing System (PPS) STORM data-order website. Existing methods of interacting with Global Precipitation Measurement (GPM) Mission data primarily focus on two-dimensional static images, whether displaying vertical slices or horizontal surface/height-level maps. These methods limit interactivity with the robust three-dimensional data coming from the GPM core satellite. Integrating the data with CesiumJS in a web-based user interface has allowed us to create the following products. We have linked with the data-order interface an on-the-fly visualization tool for any GPM/partner satellite orbit. A version of this tool also focuses on high-impact weather events. It enables viewing of combined radar and microwave-derived precipitation data on mobile devices and in a way that can be embedded into other websites. We also have used CesiumJS to visualize a method of integrating gridded precipitation data with modeled wind speeds that animates over time. Emphasis in the presentation will be placed on how a variety of technical methods were used to create these tools, and how the flexibility of the CesiumJS framework facilitates creative approaches to interact with the data.

  11. Magnetic circular Dichroism and Faraday rotation of cesium-argon excimers and cesium dimers

    International Nuclear Information System (INIS)

    Islam, M.A.

    1981-01-01

    Magnetic Circular Dichroism (MCD) and Faraday Rotation (FR) of excimer absorption bands in gases are measured to obtain the first direct information about the angular momentum quantum numbers and the angular momentum coupling schemes of excimer molecules. So far, there has been no experimental method to obtain information about the axial angular momentum and the angular momentum coupling schemes of excimer molecules. In this experiment, the MCD and the FR of cesium-argon excimer and cesium dimer absorption bands between 5000 A and 10,000 A are measured for the range of temperature from 116 0 to 355 0 C. Of particular interest is the blue wing of D 2 line in cesium which has been the subject of vigorous investigation. The measured MCD data at the blue wing of D 2 line clearly shows that the assignment of 2 μ/sub 1/2/ to this excited state assuming Hund's case (b) is a poor approximation. By a simple inspection of the MCD data, it is found that the coupling scheme is more nearly Hund's case (c) than Hynd's case (b). Several other new and interesting results are obtained. The blue wing associated with 5D transition in atomic cesium is devoid of MCD and exhibits strong MCD in the red wings. Thus, the assignment of 2 μ/sub 1/2/ and 2 π to the blue and red wings, respectively, assuming Hund's case (a) and (b), is a very good approximation. Again the yellow-green band associated with 7s-6s transition in atomic cesium shows no MCD. It is therefore also a good approximation to assign 2 μ/sub 1/2/ to the upper state assuming Hund's case (b). Much more information can be obtained by a detailed analysis of the MCD data

  12. A combined cesium-strontium extraction/recovery process

    International Nuclear Information System (INIS)

    Horwitz, E.P.; Dietz, M.L.; Jensen, M.P.

    1996-01-01

    A new solvent extraction process for the simultaneous extraction of cesium and strontium from acidic nitrate media is described. This process uses a solvent formulation comprised of 0.05 M di-t-butylcyclohexano-18-crown-6 (DtBuCH18C6), 0.1 M Crown 100' (a proprietary, cesium-selective derivative of dibenzo-18-crown-6), 1.2 M tributyl phosphate (TBP), and 5% (v/v) lauryl nitrile in an isoparaffinic hydrocarbon diluent. Distribution ratios for cesium and strontium from 4 M nitric acid are 4.13 and 3.46, respectively. A benchtop batch countercurrent extraction experiment indicates that >98% of the cesium and strontium initially present in the feed solution can be removed in only four extraction stages. Through proper choice of extraction and strip conditions, extracted cesium and strontium can be recovered either together or individually

  13. Radiation safety for incineration of radioactive waste contaminated by cesium

    International Nuclear Information System (INIS)

    Veryuzhs'kij, Yu.V.; Gryin'ko, O.M.; Tokarevs'kij, V.V.

    2016-01-01

    Problems in the treatment of radioactive waste contaminated by cesium nuclides are considered in the paper. Chornobyl experience in the management of contaminated soil and contaminated forests is analyzed in relation to the accident at Fukushima-1. The minimization of release of cesium aerosols into atmosphere is very important. Radiation influence of inhaling atmosphere aerosols polluted by cesium has damage effect for humans. The research focuses on the treatment of forests contaminated by big volumes of cesium. One of the most important technologies is a pyro-gasification incineration with chemical reactions of cesium paying attention to gas purification problems. Requirements for process, physical and chemical properties of treatment of radioactive waste based on the dry pyro-gasification incineration facilities are considered in the paper together with the discussion of details related to incineration facilities. General similarities and discrepancies in the environmental pollution caused by the accidents at Chornobyl NPP and Fukushima-1 NPP in Japan are analyzed

  14. Cesium-137 in grass from Chernobyl fallout

    International Nuclear Information System (INIS)

    Papastefanou, C.; Manolopoulou, M.; Stoulos, S.; Ioannidou, A.; Gerasopoulos, E.

    2005-01-01

    Grass ecosystem was monitored for 137 Cs, a relatively long-lived radionuclide, for about 16 years since the Chernobyl reactor accident occurred on April 26, 1986. Cesium-137 in grass gramineae or poaceae the species, ranged from 122.9 Bq kg -1 (September 4, 1986) to 5.8 mBq kg -1 (October 16, 2001) that is a range of five orders of magnitude. It was observed that there was a trend of decreasing 137 Cs with time reflecting a removal half-time of 40 months (3 1/3 years), which is the ecological half-life, T ec of 137 Cs in grassland

  15. Test for radioactive cesium in water - 1973

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Radioactive cesium in water in concentrations >1 μCi/1 is determined by gamma counting of a Cs-tetraphenylborate solution in amyl acetate. The method is limited to Cs isotopes of mass 134, 136, 137, and 138. Fission product extraction is prevented by the presence of EDTA in the solution to be extracted. Macro amounts of NH 4 + , Rb + , K + , Ag + , and Na + interfere with the determination. After the extraction and measurement of the gamma spectrum, the spectrum is resolved into its components by graphical or algebraic methods, and the count rate due to each isotope is obtained. For a single operator, precision of the method is better than +-1%

  16. Adsorption of cesium on cement mortar from aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Volchek, Konstantin, E-mail: konstantin.volchek@ec.gc.ca [Emergencies Science and Technology Section, Environment Canada, 335 River Road, Ottawa, Ontario, Canada K1A 0H3 (Canada); Miah, Muhammed Yusuf [Emergencies Science and Technology Section, Environment Canada, 335 River Road, Ottawa, Ontario, Canada K1A 0H3 (Canada); Department of Applied Chemistry and Chemical Technology, Noakhali Science and Technology University (Bangladesh); Kuang, Wenxing; DeMaleki, Zack [Emergencies Science and Technology Section, Environment Canada, 335 River Road, Ottawa, Ontario, Canada K1A 0H3 (Canada); Tezel, F. Handan [Department of Chemical and Biological Engineering, University of Ottawa, 161 Louis-Pasteur, Ottawa, Ontario, Canada K1N 6N5 (Canada)

    2011-10-30

    Highlights: {yields} The adsorption of cesium on cement mortar was investigated in a range of temperatures and cesium concentrations. {yields} The pseudo-second order kinetic model produced a good fit with the experimental kinetic data. {yields} Equilibrium test results correlated well with the Freundlich isotherm adsorption model. {yields} The interaction between cesium ions and cement mortar was dominated by chemical adsorption. - Abstract: The adsorption of cesium on cement mortar from aqueous solutions was studied in series of bench-scale tests. The effects of cesium concentration, temperature and contact time on process kinetics and equilibrium were evaluated. Experiments were carried out in a range of initial cesium concentrations from 0.0103 to 10.88 mg L{sup -1} and temperatures from 278 to 313 K using coupons of cement mortar immersed in the solutions. Non-radioactive cesium chloride was used as a surrogate of the radioactive {sup 137}Cs. Solution samples were taken after set periods of time and analyzed by inductively coupled plasma mass spectroscopy. Depending on the initial cesium concentration, its equilibrium concentration in solution ranged from 0.0069 to 8.837 mg L{sup -1} while the respective surface concentration on coupons varied from 0.0395 to 22.34 {mu}g cm{sup -2}. Equilibrium test results correlated well with the Freundlich isotherm model for the entire test duration. Test results revealed that an increase in temperature resulted in an increase in adsorption rate and a decrease in equilibrium cesium surface concentration. Among several kinetic models considered, the pseudo-second order reaction model was found to be the best to describe the kinetic test results in the studied range of concentrations. The adsorption activation energy determined from Arrhenius equation was found to be approximately 55.9 kJ mol{sup -1} suggesting that chemisorption was the prevalent mechanism of interaction between cesium ions and cement mortar.

  17. Particle swarm optimization applied to automatic lens design

    Science.gov (United States)

    Qin, Hua

    2011-06-01

    This paper describes a novel application of Particle Swarm Optimization (PSO) technique to lens design. A mathematical model is constructed, and merit functions in an optical system are employed as fitness functions, which combined radiuses of curvature, thicknesses among lens surfaces and refractive indices regarding an optical system. By using this function, the aberration correction is carried out. A design example using PSO is given. Results show that PSO as optical design tools is practical and powerful, and this method is no longer dependent on the lens initial structure and can arbitrarily create search ranges of structural parameters of a lens system, which is an important step towards automatic design with artificial intelligence.

  18. Thermochemical evaluation and preparation of cesium uranates

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Masahide; Minato, Kazuo; Fukuda, Kousaku [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Sato, Seichi; Ohashi, Hiroshi

    1997-03-01

    Two kinds of cesium uranates, Cs{sub 2}UO{sub 4} and Cs{sub 2}U{sub 2}O{sub 7}, which are predicted by thermochemical estimation to be formed in irradiated oxide fuels, were prepared from U{sub 3}O{sub 8} and Cs{sub 2}CO{sub 3} for measurements of the thermal expansions and thermal conductivities. In advance of the preparation, thermochemical calculations for the formation and decomposition of these cesium uranates were performed by Gibbs free energy minimizer. The preparation temperatures for Cs{sub 2}UO{sub 4} and Cs{sub 2}U{sub 2}O{sub 7} were determined from the results of the thermochemical calculations. The prepared samples were analyzed by X-ray diffraction, which showed that the single phases of Cs{sub 2}UO{sub 4} and Cs{sub 2}U{sub 2}O{sub 7} were formed. Thermogravimetry and differential thermal analysis were also performed on these samples, and the decomposition temperatures were evaluated. The experimental results were in good agreement with those of the thermochemical calculations. (author)

  19. Integral cesium reservoir: Design and transient operation

    Science.gov (United States)

    Smith, Joe N., Jr.; Horner, M. Harlan; Begg, Lester L.; Wrobleski, William J.

    An electrically heated thermionic converter has been designed built and successfully tested in air. One of the unique features of this converter was an integral cesium reservoir thermally coupled to the emitter. The reservoir consisted of fifteen cesiated graphite pins located in pockets situated in the emitter lead with thermal coupling to the emitter, collector and the emitter terminal; there were no auxiliary electric heaters on the reservoir. Test results are described for conditions in which the input thermal power to the converter was ramped up and down between 50% and 100% of full power in times as short as 50 sec, with data acquisition occurring every 12 sec. During the ramps the emitter and collector temperature profiles. the reservoir temperature and the electric output into a fixed load resistor are reported. The converter responded promptly to the power ramps without excessive overshoot and with no tendency to develop instabilities. This is the rust demonstration of the performance of a cesium-graphite integral reservoir in a fast transient.

  20. Intense non-relativistic cesium ion beam

    International Nuclear Information System (INIS)

    Lampel, M.C.

    1984-02-01

    The Heavy Ion Fusion group at Lawrence Berkeley Laboratory has constructed the One Ampere Cesium Injector as a proof of principle source to supply an induction linac with a high charge density and high brightness ion beam. This is studied here. An electron beam probe was developed as the major diagnostic tool for characterizing ion beam space charge. Electron beam probe data inversion is accomplished with the EBEAM code and a parametrically adjusted model radial charge distribution. The longitudinal charge distribution was not derived, although it is possible to do so. The radial charge distribution that is derived reveals an unexpected halo of trapped electrons surrounding the ion beam. A charge fluid theory of the effect of finite electron temperature on the focusing of neutralized ion beams (Nucl. Fus. 21, 529 (1981)) is applied to the problem of the Cesium beam final focus at the end of the injector. It is shown that the theory's predictions and assumptions are consistent with the experimental data, and that it accounts for the observed ion beam radius of approx. 5 cm, and the electron halo, including the determination of an electron Debye length of approx. 10 cm

  1. Microbial uptake of uranium, cesium, and radium

    Energy Technology Data Exchange (ETDEWEB)

    Strandberg, G.W.; Shumate, S.E. II; Parrott, J.R. Jr.; McWhirter, D.A.

    1980-01-01

    The ability of diverse microbial species to concentrate uranium, cesium, and radium was examined. Saccharomyces cerevisiae, Pseudomonas aeruginosa, and a mixed culture of denitrifying bacteria accumulated uranium to 10 to 15% of the dry cell weight. Only a fraction of the cells in a given population had visible uranium deposits in electron micrographs. While metabolism was not required for uranium uptake, mechanistic differences in the metal uptake process were indicated. Uranium accumulated slowly (hours) on the surface of S. cerevisiae and was subject to environmental factors (i.e., temperature, pH, interfering cations and anions). In contrast, P. aeruginosa and the mixed culture of denitrifying bacteria accumulated uranium rapidly (minutes) as dense, apparently random, intracellular deposits. This very rapid accumulation has prevented us from determining whether the uptake rate during the transient between the initial and equilibrium distribution of uranium is affected by environmental conditions. However, the final equilibrium distributions are not affected by those conditions which affect uptake by S. cerevisiae. Cesium and radium were concentrated to a considerably lesser extent than uranium by the several microbial species tested. The potential utility of microorganisms for the removal and concentration of these metals from nuclear processing wastes and several bioreactor designs for contacting microorganisms with contaminated waste streams will be discussed.

  2. Microbial uptake of uranium, cesium, and radium

    International Nuclear Information System (INIS)

    Strandberg, G.W.; Shumate, S.E. II; Parrott, J.R. Jr.; McWhirter, D.A.

    1980-01-01

    The ability of diverse microbial species to concentrate uranium, cesium, and radium was examined. Saccharomyces cerevisiae, Pseudomonas aeruginosa, and a mixed culture of denitrifying bacteria accumulated uranium to 10 to 15% of the dry cell weight. Only a fraction of the cells in a given population had visible uranium deposits in electron micrographs. While metabolism was not required for uranium uptake, mechanistic differences in the metal uptake process were indicated. Uranium accumulated slowly (hours) on the surface of S. cerevisiae and was subject to environmental factors (i.e., temperature, pH, interfering cations and anions). In contrast, P. aeruginosa and the mixed culture of denitrifying bacteria accumulated uranium rapidly (minutes) as dense, apparently random, intracellular deposits. This very rapid accumulation has prevented us from determining whether the uptake rate during the transient between the initial and equilibrium distribution of uranium is affected by environmental conditions. However, the final equilibrium distributions are not affected by those conditions which affect uptake by S. cerevisiae. Cesium and radium were concentrated to a considerably lesser extent than uranium by the several microbial species tested. The potential utility of microorganisms for the removal and concentration of these metals from nuclear processing wastes and several bioreactor designs for contacting microorganisms with contaminated waste streams will be discussed

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non-Prescription Contact Lens Laura: Vision ... Robyn: Blurry Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... in a pair of colored contact lenses, Laura Butler of Parkersburg, W.Va., had "extreme pain in ... to wear any kind of contact lens. In Butler's case, the lenses caused an infection and left ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an impulsive buy from a souvenir shop, but 10 hours after she first put in a pair ... Prescription Contact Lens Laura: Vision Loss After Just 10 Hours Robyn: Blurry Vision and Daily Eye Drops ...

  13. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over- ... without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... an ophthalmologist — an eye medical doctor — who will measure each eye and talk to you about proper ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  18. Vitrification of cesium-contaminated organic ion exchange resin

    International Nuclear Information System (INIS)

    Sargent, T.N. Jr.

    1994-08-01

    Vitrification has been declared by the Environmental Protection Agency (USEPA) as the Best Demonstrated Available Technology (BDAT) for the permanent disposal of high-level radioactive waste. Savannah River Site currently uses a sodium tetraphenylborate (NaTPB) precipitation process to remove Cs-137 from a wastewater solution created from the processing of nuclear fuel. This process has several disadvantages such as the formation of a benzene waste stream. It has been proposed to replace the precipitation process with an ion exchange process using a new resorcinol-formaldehyde resin developed by Savannah River Technical Center (SRTC). Preliminary tests, however, showed that problems such as crust formation and a reduced final glass wasteform exist when the resin is placed in the melter environment. The newly developed stirred melter could be capable of overcoming these problems. This research explored the operational feasibility of using the stirred tank melter to vitrify an organic ion exchange resin. Preliminary tests included crucible studies to determine the reducing potential of the resin and the extent of oxygen consuming reactions and oxygen transfer tests to approximate the extent of oxygen transfer into the molten glass using an impeller and a combination of the impeller and an external oxygen transfer system. These preliminary studies were used as a basis for the final test which was using the stirred tank melter to vitrify nonradioactive cesium loaded organic ion exchange resin. Results from this test included a cesium mass balance, a characterization of the semi-volatile organic compounds present in the off gas as products of incomplete combustion (PIC), a qualitative analysis of other volatile metals, and observations relating to the effect the resin had on the final redox state of the glass

  19. Vitrification of cesium-contaminated organic ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Sargent, Jr., Thomas N. [Clemson Univ., SC (United States)

    1994-08-01

    Vitrification has been declared by the Environmental Protection Agency (USEPA) as the Best Demonstrated Available Technology (BDAT) for the permanent disposal of high-level radioactive waste. Savannah River Site currently uses a sodium tetraphenylborate (NaTPB) precipitation process to remove Cs-137 from a wastewater solution created from the processing of nuclear fuel. This process has several disadvantages such as the formation of a benzene waste stream. It has been proposed to replace the precipitation process with an ion exchange process using a new resorcinol-formaldehyde resin developed by Savannah River Technical Center (SRTC). Preliminary tests, however, showed that problems such as crust formation and a reduced final glass wasteform exist when the resin is placed in the melter environment. The newly developed stirred melter could be capable of overcoming these problems. This research explored the operational feasibility of using the stirred tank melter to vitrify an organic ion exchange resin. Preliminary tests included crucible studies to determine the reducing potential of the resin and the extent of oxygen consuming reactions and oxygen transfer tests to approximate the extent of oxygen transfer into the molten glass using an impeller and a combination of the impeller and an external oxygen transfer system. These preliminary studies were used as a basis for the final test which was using the stirred tank melter to vitrify nonradioactive cesium loaded organic ion exchange resin. Results from this test included a cesium mass balance, a characterization of the semi-volatile organic compounds present in the off gas as products of incomplete combustion (PIC), a qualitative analysis of other volatile metals, and observations relating to the effect the resin had on the final redox state of the glass.

  20. Double lens collimator solar feedback sensor and master slave configuration: Development of compact and low cost two axis solar tracking system for CPV applications

    KAUST Repository

    Burhan, Muhammad

    2016-08-31

    The conventional CPV systems, as big unit design, are only suitable to be installed in the open regions, like desert areas. This gigantic system design restricts their use on the rooftop of commercial and residential buildings, unlike the conventional PV systems. This paper proposes a compact but highly accurate and cheap two axis solar tracking system, designed for CPV system field operation. The proposed system is designed and verified for tracking accuracy requirement of 0.3 degrees, and has maximum capability of as high as 0.1 degrees tracking accuracy. High tracking accuracy is ensured using in-house built double lens collimator solar feedback sensor, within a fraction of the cost of commercial solar tracking sensors. A hybrid tracking algorithm is developed in C-programming using astronomical and optical solar tracking methods. As compact CPV system design demands larger number of tracking units, for same power capacity of system. Therefore, a master slave control configuration is also proposed for the CPV field operation. Only master tracker will be equipped with the expensive tracking devices, while the required tracking information will be sent to all of the slave trackers using wireless communication through ZigBee devices. With detailed optical design, simulation and control strategy, a prototype of the proposed CPV tracking system is developed, experimentally investigated and verified for tracking accuracy for outdoor operation at the rooftop. (C) 2016 Elsevier Ltd. All rights reserved.

  1. Viscous froth lens

    Science.gov (United States)

    Green, T. E.; Bramley, A.; Lue, L.; Grassia, P.

    2006-11-01

    Microscale models of foam structure traditionally incorporate a balance between bubble pressures and surface tension forces associated with curvature of bubble films. In particular, models for flowing foam microrheology have assumed this balance is maintained under the action of some externally imposed motion. Recently, however, a dynamic model for foam structure has been proposed, the viscous froth model, which balances the net effect of bubble pressures and surface tension to viscous dissipation forces: this permits the description of fast-flowing foam. This contribution examines the behavior of the viscous froth model when applied to a paradigm problem with a particularly simple geometry: namely, a two-dimensional bubble “lens.” The lens consists of a channel partly filled by a bubble (known as the “lens bubble”) which contacts one channel wall. An additional film (known as the “spanning film”) connects to this bubble spanning the distance from the opposite channel wall. This simple structure can be set in motion and deformed out of equilibrium by applying a pressure across the spanning film: a rich dynamical behavior results. Solutions for the lens structure steadily propagating along the channel can be computed by the viscous froth model. Perturbation solutions are obtained in the limit of a lens structure with weak applied pressures, while numerical solutions are available for higher pressures. These steadily propagating solutions suggest that small lenses move faster than large ones, while both small and large lens bubbles are quite resistant to deformation, at least for weak applied back pressures. As the applied back pressure grows, the structure with the small lens bubble remains relatively stiff, while that with the large lens bubble becomes much more compliant. However, with even further increases in the applied back pressure, a critical pressure appears to exist for which the steady-state structure loses stability and unsteady

  2. Modeling of a diode-pumped thin-disk cesium vapor laser

    Science.gov (United States)

    An, Guofei; Cai, He; Liu, Xiaoxu; Han, Juhong; Zhang, Wei; Wang, Hongyuan; Wang, You

    2018-03-01

    A diode pumped alkali laser (DPAL) provides a significant potential for construction of high-powered lasers. Until now, a series of models have been established to analyze the kinetic process and most of them are based on the end-pumped alkali laser system in which the vapor cell are usually cylindrical and cuboid. In this paper, a mathematic model is constructed to investigate the kinetic processes of a diode pumped thin-disk cesium vapor laser, in which the cesium vapor and the buffer gases are beforehand filled in a sealed glass cell with a thin-disk structure. We systemically study the influences of the cell temperature and cell thickness on the output features of a thin-disk DPAL. Further, we study the thin-disk DPAL with the W-shaped resonator and multiple-disk configuration. To the best of our knowledge, there have not been any similar reports so far.

  3. Projection-type integral imaging system using a three-dimensional screen composed of a lens array and a retroreflector film.

    Science.gov (United States)

    Kim, Young Min; Song, Byoungsub; Min, Sung-Wook

    2017-05-01

    We propose an improved projection-type integral imaging system using a three-dimensional (3D) screen consisting of a lens array and a retroreflector film in this paper. The projection-type integral imaging system suffers from the disadvantage of low-visibility images because of the inherently small exit pupil size of the projector. In order to resolve this problem, we adopt a 3D screen to avoid the demerits of a diffuser screen, such as off-screen image blur and loss of parallax. To determine the appropriate configuration of the 3D screen in the system, a simulation based on a ray transfer matrix analysis method was performed. The results show that the 3D screen should be located near the central depth plane of the integral imaging system, which leads to the conclusion that only the real mode is available for the proposed system. Experiments to verify this configuration and the feasibility of the proposed system were conducted using a system constructed with a real mode integral imaging system including a convex mirror array, which can fundamentally eliminate the pseudoscopic problem.

  4. Thermodynamics of soluble fission products cesium and iodine in the Molten Salt Reactor

    Science.gov (United States)

    Capelli, E.; Beneš, O.; Konings, R. J. M.

    2018-04-01

    The present study describes the full thermodynamic assessment of the Li,Cs,Th//F,I system. The existing database for the relevant fluoride salts considered as fuel for the Molten Salt Reactor (MSR) has been extended with two key fission products, cesium and iodine. A complete evaluation of all the common-ion binary and ternary sub-systems of the LiF-ThF4-CsF-LiI-ThI4-CsI system has been performed and the optimized parameters are presented in this work. New equilibrium data have been measured using Differential Scanning Calorimetry and were used to assess the reciprocal ternary systems and confirm the extrapolated phase diagrams. The developed database significantly contributes to the understanding of the behaviour of cesium and iodine in the MSR, which strongly depends on their concentration and chemical form. Cesium bonded with fluorine is well retained in the fuel mixture while in the form of CsI the solubility of these elements is very limited. Finally, the influence of CsI and CsF on the physico-chemical properties of the fuel mixture was calculated as function of composition.

  5. Seaweed against strontium and preussian blue against cesium

    Directory of Open Access Journals (Sweden)

    G Michanek

    1988-06-01

    Full Text Available The fact that alginates bind strontium and cyanates bind cesium and are capable of removing these elements from living organisms is scientifically verified. Zeolites offer another possibility for exchange of these ions. Practical research should be initiated to find the right doses and procedure to decrease the body burden of radioactive isotopes in reindeer.Alger mot strontium och berlinerblått mot cesium.Abstract in Swedish / Sammanfattning: Mitt budskap år kort: Alger binder strontium, Berlinerblått binder cesium, Sätt fart på forskning och forsök!

  6. On the cesium-rich part of the Cs-Te phase diagram

    International Nuclear Information System (INIS)

    Boer, R. de; Cordfunke, E.H.P.

    1995-03-01

    The cesium-tellurium system in the region between 33 and 55 at.% Te has been investigated with X-ray diffraction and DSC. The existence of the compounds Cs 5 Te 3 and CsTe is demonstrated. The latter compound exhibits a structural transition at elevated temperature, as does the compound Cs 2 Te. The earlier reported compounds Cs 3 Te 2 and Cs 5 Te 4 do not exist. (orig.)

  7. Management of cesium loaded AMP- Part I preparation of 137Cesium concentrate and cementation of secondary wastes

    International Nuclear Information System (INIS)

    Singh, I.J.; Sathi Sasidharan, N.; Yalmali, Vrunda S.; Deshingkar, D.S.; Wattal, P.K.

    2005-11-01

    Separation of 137 cesium from High Level Waste can be achieved by use of composite-AMP, an engineered form of Ammonium Molybdo-Phosphate(AMP). Direct vitrification of cesium loaded composite AMP in borosilicate glass matrix leads to separation of water soluble molybdate phase. A proposed process describes two different routes of selective separation of molybdates and phosphate to obtain solutions of cesium concentrates. Elution of 137 Cesium from composite-AMP by decomposing it under flow conditions using saturated barium hydroxide was investigated. This method leaves molybdate and phosphate embedded in the column but only 70% of total cesium loaded on column could be eluted. Alternatively composite-AMP was dissolved in sodium hydroxide and precipitation of barium molybdate-phosphate from the resultant solution, using barium nitrate was investigated by batch methods. The precipitation technique gave over 99.9% of 137 Cesium activity in solutions, free of molybdates and phosphates, which is ideally suited for immobilization in borosilicate glass matrix. Detailed studies were carried out to immobilize secondary waste of 137 Cesium contaminated barium molybdate-phosphate precipitates in the slag cement matrix using vermiculite and bentonite as admixtures. The cumulative fraction of 137 Cs leached from the cement matrix blocks was 0.05 in 140 days while the 137 Cs leach rate was 0.001 gm/cm 2 /d. (author)

  8. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  9. Cesium removal demonstration utilizing crystalline silicotitanate sorbent for processing Melton Valley Storage Tank supernate: Final report

    International Nuclear Information System (INIS)

    Walker, J.F. Jr.; Taylor, P.A.; Cummins, R.L.

    1998-03-01

    This report provides details of the Cesium Removal Demonstration (CsRD), which was conducted at Oak Ridge National Laboratory (ORNL) on radioactive waste from the Melton Valley Storage Tanks. The CsRD was the first large-scale use of state-of-the-art sorbents being developed by private industry for the selective removal of cesium and other radionuclides from liquid wastes stored across the DOE complex. The crystalline silicotitanate sorbent used in the demonstration was chosen because of its effectiveness in laboratory tests using bench-scale columns. The demonstration showed that the cesium could be removed from the supernate and concentrated on a small-volume, solid waste form that would meet the waste acceptance criteria for the Nevada Test Site. During this project, the CsRD system processed > 115,000 L (30,000 gal) of radioactive supernate with minimal operational problems. Sluicing, drying, and remote transportation of the sorbent, which could not be done on a bench scale, were successfully demonstrated. The system was then decontaminated to the extent that it could be contact maintained with the use of localized shielding only. By utilizing a modular, transportable design and placement within existing facilities, the system can be transferred to different sites for reuse. The initial unit has now been removed from the process building and is presently being reinstalled for use in baseline operations at ORNL

  10. Cesium removal demonstration utilizing crystalline silicotitanate sorbent for processing Melton Valley Storage Tank supernate: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Walker, J.F. Jr.; Taylor, P.A.; Cummins, R.L. [and others

    1998-03-01

    This report provides details of the Cesium Removal Demonstration (CsRD), which was conducted at Oak Ridge National Laboratory (ORNL) on radioactive waste from the Melton Valley Storage Tanks. The CsRD was the first large-scale use of state-of-the-art sorbents being developed by private industry for the selective removal of cesium and other radionuclides from liquid wastes stored across the DOE complex. The crystalline silicotitanate sorbent used in the demonstration was chosen because of its effectiveness in laboratory tests using bench-scale columns. The demonstration showed that the cesium could be removed from the supernate and concentrated on a small-volume, solid waste form that would meet the waste acceptance criteria for the Nevada Test Site. During this project, the CsRD system processed > 115,000 L (30,000 gal) of radioactive supernate with minimal operational problems. Sluicing, drying, and remote transportation of the sorbent, which could not be done on a bench scale, were successfully demonstrated. The system was then decontaminated to the extent that it could be contact maintained with the use of localized shielding only. By utilizing a modular, transportable design and placement within existing facilities, the system can be transferred to different sites for reuse. The initial unit has now been removed from the process building and is presently being reinstalled for use in baseline operations at ORNL.

  11. Cesium and strontium in Black Sea macroalgae.

    Science.gov (United States)

    Nonova, Tzvetana; Tosheva, Zornitza

    2014-03-01

    The trace level of metals and particularly radioactive ones should be monitored to evaluate the transfer along the trophic chain, assess the risk for biota and can be used for global changes assessment. Plants respond rapidly to all changes in the ecosystem conditions and are widely used as indicators and predictors for changes in hydrology and geology. In this work we represent our successful development and applications of a methodology for monitoring of stable and radioactive strontium and cesium in marine biota (Black Sea algae's). In case of radioactive release they are of high interest. We use ED-XRF, gamma spectrometers and LSC instrumentation and only 0.25 g sample. Obtained results are compared with those of other authors in same regions. The novelty is the connection between the radioactive isotopes and their stable elements in algae in time and space scale. All our samples were collected from Bulgarian Black Sea coast. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Biosorption of uranium, radium, and cesium

    International Nuclear Information System (INIS)

    Strandberg, G.W.

    1982-01-01

    Some fundamental aspects of the biosorption of metals by microbial cells were investigated. These studies were carried out in conjunction with efforts to develop a process to utilize microbial cells as biosorbents for the removal of radionuclides from waste streams generated by the nuclear fuel cycle. It was felt that an understanding of the mechanism(s) of metal uptake would potentially enable the enhancement of the metal uptake phenomenon through environmental or genetic manipulation of the microorganisms. Also presented are the results of a preliminary investigation of the applicability of microorganisms for the removal of 137 cesium and 226 radium from existing waste solutions. The studies were directed primarily at a characterization of uranium uptake by the yeast, Saccharomyces cerevisiae, and the bacterium, Pseudomonas aeruginosa

  13. Social aspects concerning the cesium-137 accident

    International Nuclear Information System (INIS)

    Chaves, Elza Guedes

    1997-01-01

    The present work aims to understand how social representations constructed upon nuclear energy have influenced on molding and orienting public's behavior in the presence of the accident that occurred in Goiania with the capsule of Cesium-137. As a starting point, it is accepted here that panic caused by that accident could be properly understood only if dimension of subjectivity is taken into consideration. This perspective is required whenever events that put human life and environment in risk happen. Facing the accident, people internalized radioactivity, an unknown element, as certainty of cancer and death despite the fact that cancer and death could only outcome in case there had been excessive exposure to radioactivity. (author)

  14. On mobility of cesium-137, sodium, potassium in various types of soils and prediction of cesium-137 cumulation in agricultural plants

    International Nuclear Information System (INIS)

    Ashkinazi, Eh.I.

    1990-01-01

    Mobility of cesium-137, sodium and potassium in the natural environment in podzolic gray and chernozem medium-loamy, sward podzolic sandy soils and chernozem has been studied. Durability of fixation of cesium-137 increases in a number of soils and increase of the level of metabolic potassium. Coefficient of transition of level of metabolic cesium-137 by potassium and sodium, and of sodium by potassium. The mentioned above coefficients can be used for the prediction of cesium-137 cumulation in plants

  15. Hyperfine structure, nuclear spins and magnetic moments of some cesium isotopes

    International Nuclear Information System (INIS)

    Ekstroem, C.; Ingelman, S.; Wannberg, G.

    1977-03-01

    Using an atomic-beam magnetic resonance apparatus connected on-line with the ISOLDE isotope separator, CERN, hyperfine structure measurements have been performed in the 2 Ssub(1/2) electronic ground state of some cesium isotopes. An on-line oven system which efficiently converts a mass separated ion-beam of alkali isotopes to an atomic beam is described in some detail. Experimentally determined nuclear spins of sup(120, 121, 121m, 122, 122m, 123, 124, 126, 128, 130m, 135m)Cs and magnetic moments of sup(122, 123, 124, 126, 128, 130)Cs are reported and discussed in terms of different nuclear models. The experimental data indicate deformed nuclear shapes of the lightest cesium isotopes. (Auth.)

  16. Influence of metallic silver and oxygen on the radiolysis of cesium iodide solutions

    International Nuclear Information System (INIS)

    Furrer, M.; Gloor, T.

    1988-01-01

    Silver iodide formation by radiolysis has been studied in the system water/cesium iodide/silver metal. In a number of scenarios for hypothetical core melt accidents, silver iodide has been considered as an effective scavenger for fission product iodine. The influence of dissolved oxygen and the consequences of a variable silver/cesium iodide ratio are shown in detail. Partial kinetic reaction constants for the different parameters are presented and it is shown that they can be simply added together to form an overall reaction rate constant. In a radiation field just short of 5 kGy/h, the influences of oxygen (air) and of the radiation are of the same order of magnitude. A linear relation is shown between specific metal surface and reaction rates. Data shown are compatible with earlier measurements made at Oak Ridge National Laboratory, US

  17. Cesium carbonate mediated exclusive dialkylation of active methylene compounds

    Directory of Open Access Journals (Sweden)

    Ulaganathan Sankar

    2012-07-01

    Full Text Available Active methylene compounds are regioselectively dialkylated by variety of alkyl halides using cesium carbonate in quantitative yield. The reaction yielded exclusively dialkylated products with no intermediate monoalkyaltion or mixture of products.

  18. A model for radial cesium transport in a fuel pellet

    International Nuclear Information System (INIS)

    Imoto, Shosuke

    1989-01-01

    In order to explain the radial redistribution of cesium in an irradiated pellet, a two-step release model is proposed. The first step involves the migration of cesium by atomic diffusion to some channels, such as grain boundaries and cracks, and the second step assumes a thermomigration down along the temperature gradient. Distribution profiles of cesium are obtained by numerical calculation with the present model assuming a constant and spatially uniform birth rate of cesium in the pellet. The result agrees well with the profile observed by micro-gamma scanning for the LWR fuel in the outer region of the pellet but diverges from it at the inner region. Discussion is made on the steady-state model hitherto generally utilized. (orig.)

  19. Low-energy vibrational dynamics of cesium borate glasses.

    Science.gov (United States)

    Crupi, C; D'Angelo, G; Vasi, C

    2012-06-07

    Low-temperature specific heat and inelastic light scattering experiments have been performed on a series of cesium borate glasses and on a cesium borate crystal. Raman measurements on the crystalline sample have revealed the existence of cesium rattling modes in the same frequency region where glasses exhibit the boson peak (BP). These localized modes are supposed to overlap with the BP in cesium borate glasses affecting its magnitude. Their influence on the low frequency vibrational dynamics in glassy samples has been considered, and their contribution to the specific heat has been estimated. Evidence for a relation between the changes of the BP induced by the increased amount of metallic oxide and the variations of the elastic medium has been provided.

  20. Strontium-90 and cesium-137 in tea (Japanese tea)

    International Nuclear Information System (INIS)

    1982-01-01

    Strontium-90 and cesium-137 in tea (Japanese tea) were determined. Five hundred grams of manufactured green tea was collected from six sampling locations in Japan. The results are shown in a table. (Namekawa, K.)

  1. Zirconium phosphate waste forms for low-temperature stabilization of cesium-137-containing waste streams

    International Nuclear Information System (INIS)

    Singh, D.; Wagh, A.S.; Tlustochowicz.

    1996-04-01

    Novel chemically bonded phosphate ceramics are being developed and fabricated for low-temperature stabilization and solidification of waste streams that are not amenable to conventional high-temperature stabilization processes because volatiles are present in the wastes. A composite of zirconium-magnesium phosphate has been developed and shown to stabilize ash waste contaminated with a radioactive surrogate of 137 Cs. Excellent retainment of cesium in the phosphate matrix system was observed in Toxicity Characteristic Leaching Procedure tests. This was attributed to the capture of cesium in the layered zirconium phosphate structure by intercalation ion-exchange reaction. But because zirconium phosphate has low strength, a novel zirconium/magnesium phosphate composite waste form system was developed. The performance of these final waste forms, as indicated by compression strength and durability in aqueous environments, satisfy the regulatory criteria. Test results indicate that zirconium-magnesium-phosphate-based final waste forms present a viable technology for treatment and solidification of cesium-contaminated wastes

  2. Cesium powder and pellets inner container decontamination method determination

    International Nuclear Information System (INIS)

    Ferrell, P.C.

    1998-01-01

    The cesium powder and pellets inner container is to be performance tested per the criteria specified in Section 4.0 of HNF-2399, ''Design, Fabrication, and Assembly Criteria for Cesium Powder and Pellet Inner Container.'' The test criteria specifies that the inner container be water tight during decontamination of the exterior surface. Three prototypes will be immersed into a pool of water to simulate a water decontamination process

  3. Study of strontium and cesium migration in fractured crystalline rock

    International Nuclear Information System (INIS)

    Gustafsson, E.; Klockars, C.E.

    1984-01-01

    The purpose of this investigation has been to study the retardation and dilution of non-active strontium and cesium relative to a non-absorbing substance (iodide) in a well-defined fracture zone in the Finnsjoen field research area. The investigation was carried out in a previously tracer-tested fracture zone. The study has encompassed two separate test runs with prolonged injection of strontium and iodide and of cesium and iodide. The test have shown that: - Strontium is not retarded, but rather absorbed to about 40% at equilibrium. - At injection stop, 36.3% of the injected mass of strontium has been absorbed and there is no deabsorption. -Cesium is retarded a factor of 2-3 and absorbed to about 30% at equilibrium. - At injection stop, 39.4% of the injected mass of cesium has been absorbed. Cesium is deabsorbed after injection stop (400h) and after 1300 hours, only 22% of the injected mass of cesium is absorbed. (author)

  4. Novel matching lens and spherical ionizer for a cesium sputter ion ...

    Indian Academy of Sciences (India)

    Department of Nuclear Physics, Research School of Physical Sciences and Engineering,. Australian National University ... plishing the acceleration of beam particles from eV to keV energy, minimizing space charge effects and interactions .... One could gain the benefits of the higher C energy by just increasing the extractor.

  5. Novel matching lens and spherical ionizer for a cesium sputter ion ...

    Indian Academy of Sciences (India)

    The beam optics of a multi-sample sputter ion source, based on the NEC MCSNICS, has been modified to accommodate cathode voltages higher than 5 kV and dispenses with the nominal extractor. The cathode voltage in Cs sputter sources plays the role of the classical extractor accomplishing the acceleration of beam ...

  6. Seasonal variation of cesium 134 and cesium 137 in semidomestic reindeer in Norway after the Chernobyl accident

    Directory of Open Access Journals (Sweden)

    I.M. H. Eikelmann

    1990-09-01

    Full Text Available The Chernobyl accident had a great impact on the semidomestic reindeer husbandry in central Norway. Seasonal differences in habitat and diet resulted in large variations in observed radiocesium concentrations in reindeer after the Chernobyl accident. In three areas with high values of cesium-134 and cesium-137 in lichens, the main feed for reindeer in winter, reindeer were sampled every second month to monitor the seasonal variation and the decrease rate of the radioactivity. The results are based on measurements of cesium-134 and cesium-137 content in meat and blood and by whole-body monitoring of live animals. In 1987 the increase of radiocesium content in reindeer in Vågå were 4x from August to January. The mean reductions in radiocesium content from the winter 1986/87 to the winter 1987/88 were 32%, 50% and 43% in the areas of Vågå, Østre-Namdal and Lom respectively.

  7. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  8. Prussian blue as an antidote for radioactive thallium and cesium poisoning

    Directory of Open Access Journals (Sweden)

    Altagracia-Martinez M

    2012-06-01

    Full Text Available Marina Altagracia-Martínez, Jaime Kravzov-Jinich, Juan Manuel Martínez-Núñez, Camilo Ríos-Castañeda, Francisco López-NaranjoDepartments of Biological Systems and Health Care, Biological and Health Sciences Division, Universidad Autónoma Metropolitana-Xochimilco, Mexico DF, MexicoBackground: Following the attacks on the US on September 11, 2001, potentially millions of people might experience contamination from radioactive metals. However, before the specter of such accidents arose, Prussian blue was known only as an investigational agent for accidental thallium and cesium poisoning. The purpose of this review is to update the state of the art concerning use of Prussian blue as an effective and safe drug against possible bioterrorism attacks and to disseminate medical information in order to contribute to the production of Prussian blue as a biodefense drug.Methods: We compiled articles from a systematic review conducted from January 1, 1960 to March 30, 2011. The electronic databases consulted were Medline, PubMed, the Cochrane Library, and Scopus.Results: Prussian blue is effective and safe for use against radioactive intoxications involving cesium-137 and thallium. The US Food and Drug Administration has approved Prussian blue as a drug, but there is only one manufacturer providing Prussian blue to the US. Based on the evidence, Prussian blue is effective for use against radioactive intoxications involving cesium-137 and thallium, but additional clinical research on and production of Prussian blue are needed.Keywords: Prussian blue, radioactive cesium, thallium, intoxication, biodefense drug

  9. Hepatic cholesterol metabolism following a chronic ingestion of cesium-137 starting at fetal stage in rats

    International Nuclear Information System (INIS)

    Racine, R.; Grandcolas, L.; Blanchardon, E.; Gourmelon, P.; Souidi, M.; Veyssiere, G.

    2010-01-01

    The Chernobyl accident released many radionuclides in the environment. Some are still contaminating the ground and thus the people through dietary intake. The long-term sanitary consequences of this disaster are still unclear and several biological systems remain to be investigated. Cholesterol metabolism is of particular interest, with regard to the link established between atherosclerosis and exposure to high-dose ionizing radiations. This study assesses the effect of cesium-137 on cholesterol metabolism in rats, after a chronic exposure since fetal life. To achieve this, rat dams were contaminated with cesium-137-supplemented water from two weeks before mating until the weaning of the pups. Thereafter, the weaned rats were given direct access to the contaminated drinking water until the age of 9 months. After the sacrifice, cholesterol metabolism was investigated in the liver at gene expression and protein level. The cholesterolemia was preserved, as well as the cholesterol concentration in the liver. At molecular level, the gene expressions of ACAT 2 (a cholesterol storage enzyme), of Apolipoprotein A-I and of RXR (a nuclear receptor involved in cholesterol metabolism) were significantly decreased. In addition, the enzymatic activity of CYP27A1, which catabolizes cholesterol, was increased. The results indicate that the rats seem to adapt to the cesium-137 contamination and display modifications of hepatic cholesterol metabolism only at molecular level and within physiological range. (author)

  10. Cesium Accumulation and Growth Characteristics of Rhodococcus erythropolis CS98 and Rhodococcus sp. Strain CS402

    OpenAIRE

    Tomioka, Noriko; Uchiyama, Hiroo; Yagi, Osami

    1994-01-01

    Growth and cesium accumulation characteristics of two cesium-accumulating bacteria isolated from soils were investigated. Rhodococcus erythropolis CS98 and Rhodococcus sp. strain CS402 accumulated high levels of cesium (approximately 690 and 380 μmol/g [dry weight] of cells or 92 and 52 mg/g [dry weight] of cells, respectively) after 24 h of incubation in the presence of 0.5 mM cesium. The optimum pH for cesium uptake by both Rhodococcus strains was 8.5. Rubidium and cesium assumed part of th...

  11. Disposable contact lenses vs. contact lens maintenance for extended wear.

    Science.gov (United States)

    Josephson, J E; Caffery, B E; Campbell, I; Slomovic, A R

    1990-01-01

    We compared a disposable extended wear contact lens modality with conventional extended wear over a 6-week period. To do so, we refit 31 patients who had successfully worn conventional extended wear contact lenses for more than 1 year. One eye was fit with the AcuvueR disposable contact lens, and a new extended wear lens of the type the patient had been wearing was placed on the other eye. At weekly intervals the disposable lens was discarded and a new disposable lens inserted. At the same time, the conventional lens on the fellow eye was cleaned, disinfected, and reinserted. After 6 weeks the ocular response, subjective impressions, and condition of the lenses in the two eyes were compared. Both lenses were then cultured. Three subjects had to discontinue disposable lens wear because of adverse reactions to trapped cellular debris and corneal microcysts. Although the results were not statistically significant, the Acuvue lens appeared to perform better than or equal to the conventional lens in biomicroscopic observation, visual acuity measurement, and subjective patient preference. Eighty-seven percent of patients preferred to continue with the disposable system. There were no differences found in the type or degree of microbial contamination of the lenses.

  12. Introduction to designing information and organizations with a positive lens

    NARCIS (Netherlands)

    Avital, M.; Boland, R.J.; Lyytinen, K.

    2009-01-01

    The role and potential contribution of a positive lens to the design of systems and organizations is the focus of this introductory essay. The positive lens refers to a perspective in the social sciences that emphasizes the capacity of people and organizations to construct better work environments,

  13. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ...

  16. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  17. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  19. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  20. Thermal Lens Microscope

    Science.gov (United States)

    Uchiyama, Kenji; Hibara, Akihide; Kimura, Hiroko; Sawada, Tsuguo; Kitamori, Takehiko

    2000-09-01

    We developed a novel laser microscope based on the thermal lens effect induced by a coaxial beam comprised of excitation and probe beams. The signal generation mechanism was confirmed to be an authentic thermal lens effect from the measurement of signal and phase dependences on optical configurations between the sample and the probe beam focus, and therefore, the thermal lens effect theory could be applied. Two-point spatial resolution was determined by the spot size of the excitation beam, not by the thermal diffusion length. Sensitivity was quite high, and the detection ability, evaluated using a submicron microparticle containing dye molecules, was 0.8 zmol/μm2, hence a distribution image of trace chemical species could be obtained quantitatively. In addition, analytes are not restricted to fluorescent species, therefore, the thermal lens microscope is a promising analytical microscope. A two-dimensional image of a histamine molecule distribution, which was produced in mast cells at the femtomole level in a human nasal mucous polyp, was obtained.

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact ... After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter ...

  2. Simulation of Sediment and Cesium Transport in the Ukedo River and the Ogi Dam Reservoir during a Rainfall Event using the TODAM Code

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Yasuo; Yokuda, Satoru T.; Kurikami, Hiroshi

    2014-03-28

    flow moving through these reservoirs. • The reservoirs play a major role as a sink of sediment and cesium in the river systems. Some amounts of sediment pass through them along with cesium in dissolved and clay-sorbed cesium forms. • Effects of countermeasures such as overland decontamination, dam control and sorbent injection were tentatively estimated. The simulation suggested that overland decontamination and sorbent injection would be effective for decreasing the contamination of water in the reservoir and in the river below the dam.

  3. Biopsy Diagnosis of Oral Carcinoma by the Combination of Morphological and Spectral Methods Based on Embedded Relay Lens Microscopic Hyperspectral Imaging System.

    Science.gov (United States)

    Ou-Yang, Mang; Hsieh, Yao-Fang; Lee, Cheng-Chung

    Cytopathological examination through biopsy is very important for carcinoma detection. The embedded relay lens microscopic hyperspectral imaging system (ERL-MHIS) provides a morphological image of a biopsy sample and the spectrum of each pixel in the image simultaneously. Based on the ERL-MHIS, this work develops morphological and spectral methods to diagnose oral carcinoma biopsy. In morphological discrimination, the fractal dimension method is applied to differentiate between normal and abnormal tissues. In spectral identification, normal and cancerous cells are distinguished using five methods. However, the spectra of normal and cancerous cells vary with patient. The diagnostic performances of the five methods are thus not ideal. Hence, the proposed cocktail approach is used to determine the effectiveness of the spectral methods in correlating with the sampling conditions. And then we use a combination of effective spectral methods according to the sample conditions for diagnosing a sample. A total of 68 biopsies from 34 patients are analyzed using the ERL-MHIS. The results demonstrate a sensitivity of 90 ± 4.53 % and a specificity of 87.8 ± 5.21 %. Furthermore, in our survey, this system is the first time utilized to study oral carcinoma biopsies.

  4. Outdoor overall performance of a novel air-gap-lens-walled compound parabolic concentrator (ALCPC) incorporated with photovoltaic/thermal system

    International Nuclear Information System (INIS)

    Li, Guiqiang; Pei, Gang; Ji, Jie; Su, Yuehong

    2015-01-01

    Highlights: • A prototype of an ALCPC-PV/T system was designed and set up. • Good optical agreements were observed between simulation and experiment. • The effects of the temperature on the electrical characteristics were discussed. • The thermal performance for circulating cooling was analyzed. • The system efficiency was calculated to present the overall performance. - Abstract: A novel air-gap-lens-walled compound parabolic concentrator incorporated with photovoltaic/thermal system (ALCPC-PV/T) was proposed. The optical, electrical and thermal performances of the ALCPC-PV/T under the outdoor condition were analyzed for building integrated concentrating photovoltaic/thermal application. The simulation and experiment were carried out to reveal the optical characteristics of ALCPC-PV/T on two typical days. The experiment results verified the optical simulation results that the ALCPC-PV/T system had a half acceptance angle of 35° and an average optical efficiency of 83.0% within the half acceptance angle for direct incidence. Furthermore, the average optical efficiencies on the two typical days were all above 60% under the actual outdoor condition considering direct and diffuse solar radiation. Details of electrical characteristics affected by the temperature of circulating cooling water were also displayed. The electrical and thermal efficiencies of the ALCPC-PV/T system during the test were 6.0% and 35.0% respectively with the final water temperature of 70 °C. In addition, the fitted results indicated that under the zero reduced temperature condition, the thermal efficiency of the ALCPC PV/T system was 52.0%, and the corresponding electrical efficiency was 6.6%

  5. Clinical survey of lens care in contact lens patients.

    Science.gov (United States)

    Ky, W; Scherick, K; Stenson, S

    1998-10-01

    Overall, contact lenses provide a safe and effective modality for vision correction. However, problems do occasionally arise. Up to 80% of contact lens complications can be traced to poor patient compliance with recommended lens care guidelines. We conducted a survey to evaluate the level of patient compliance in specific areas of lens care and maintenance and to assess patient knowledge of basic contact lens information. Patients were asked to complete an anonymous 15 question survey that focused on lens care--specifically the use of contact lens cleaners, methods of disinfection, enzyme treatments, use of rewetting drops, and the frequency of follow-up exams. In addition, the survey included six true/false questions relating to contact lens care and safety. There were a total of 103 participants in the study. Approximately 24% of patients stated they never cleaned their lenses prior to disinfection, and 5% used saline solutions as their primary mode of disinfection. A sizable portion of those surveyed (43% of soft lens wearers and 71% of rigid gas permeable lens wearers) either never used enzyme cleaners or used them less than once a month. Seventy percent of patients either never used rewetting drops or used them less than once a day. Twenty-nine percent of patients consulted their eye care professionals every 2 years and 6% less often than every two years. Six questions assessed patient knowledge of contact lens care safety. Of a possible six out of six correct answers, the mean number of correct responses was 3.74. A sizable proportion of contact lens wearers do not adequately adhere to recommended contact lens care, and many have an inadequate understanding of contact lens care guidelines. Therefore, it is important that practitioners place more emphasis on patient education at the time of initial contact lens fitting and reinforce such instruction during follow-up visits.

  6. A lazy way to design infrared lens

    Science.gov (United States)

    Qiu, RongSheng; Wu, JianDong; Chen, LongJiang; Yu, Kun; Pang, HaoJun; Hu, BaiZhen

    2017-08-01

    We designed a compact middle-wave infrared (MWIR) lens with a large focal length ratio (about 1.5:1), used in the 3.7 to 4.8 μm range. The lens is consisted of a compact front group and a re-imaging group. Thanks to the compact front group configuration, it is possible to install a filter wheel mechanism in such a tight space. The total track length of the lens is about 50mm, which includes a 2mm thick protective window and a cold shield of 12mm. The full field of view of the lens is about 3.6°, and F number is less than 1.6, the image circle is about 4.6mm in diameter. The design performance of the lens reaches diffraction limitation, and doesn't change a lot during a temperature range of -40°C +60°C. This essay proposed a stepwise design method of infrared optical system guided by the qualitative approach. The method fully utilize the powerful global optimization ability, with a little effort to write code snippet in optical design software, frees optical engineer from tedious calculation of the original structure.

  7. Candidate gravitational microlensing events for future direct lens imaging

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, C. B.; Gould, A.; Gaudi, B. S. [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Park, H.; Han, C. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Sumi, T.; Koshimoto, N. [Department of Earth and Space Science, Osaka University, Osaka 560-0043 (Japan); Udalski, A. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Bozza, V. [Department of Physics, University of Salerno, I-84084 Fisciano (Italy); Abe, F.; Fukunaga, D.; Itow, Y.; Masuda, K. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Bennett, D. P. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556-5670 (United States); Bond, I. A.; Ling, C. H. [Institute of Information and Mathematical Sciences, Massey University, Private Bag 102-904, North Shore Mail Centre, Auckland 0745 (New Zealand); Botzler, C. S.; Freeman, M. [Department of Physics, University of Auckland, Private Bag 92-019, Auckland 1001 (New Zealand); Fukui, A. [School of Chemical and Physical Sciences, Victoria University, Wellington 6140 (New Zealand); Collaboration: MOA Collaboration; OGLE Collaboration; μFUN Collaboration; RoboNet Collaboration; and others

    2014-10-10

    The mass of the lenses giving rise to Galactic microlensing events can be constrained by measuring the relative lens-source proper motion and lens flux. The flux of the lens can be separated from that of the source, companions to the source, and unrelated nearby stars with high-resolution images taken when the lens and source are spatially resolved. For typical ground-based adaptive optics (AO) or space-based observations, this requires either inordinately long time baselines or high relative proper motions. We provide a list of microlensing events toward the Galactic bulge with high relative lens-source proper motion that are therefore good candidates for constraining the lens mass with future high-resolution imaging. We investigate all events from 2004 to 2013 that display detectable finite-source effects, a feature that allows us to measure the proper motion. In total, we present 20 events with μ ≳ 8 mas yr{sup –1}. Of these, 14 were culled from previous analyses while 6 are new, including OGLE-2004-BLG-368, MOA-2005-BLG-36, OGLE-2012-BLG-0211, OGLE-2012-BLG-0456, MOA-2012-BLG-532, and MOA-2013-BLG-029. In ≲12 yr from the time of each event the lens and source of each event will be sufficiently separated for ground-based telescopes with AO systems or space telescopes to resolve each component and further characterize the lens system. Furthermore, for the most recent events, comparison of the lens flux estimates from images taken immediately to those estimated from images taken when the lens and source are resolved can be used to empirically check the robustness of the single-epoch method currently being used to estimate lens masses for many events.

  8. Preliminary Ion Exchange Modeling for Removal of Cesium from Hanford Waste Using SuperLig 644 Resin

    International Nuclear Information System (INIS)

    Hamm, L.L.

    2000-01-01

    A proposed facility is being designed for the immobilization of Hanford high-level radioactive waste. One unit process in the facility is designed to remove radioactive cesium by ion-exchange from the strongly alkaline aqueous phase. A resin specifically designed with high selectivity of cesium under alkaline conditions is being investigated. The resin also is elutable under more acidic conditions. The proposed design of the facility consists of two sets of two packed columns placed in series (i.e., a lead column followed by a lag (guard) column configuration). During operation, upon reaching a specified cesium concentration criterion at the exit of the lag column, operation is switched to the second set of lead and lag columns. The cesium-loaded lead column is processed (i.e., washed and eluted) and switched to the lag position. the previous lag column is then placed in the lead position (without eluting) and the system is ready for use in the next cycle. For a well designed process, the loading and elution processes result in significant volume reductions in aqueous high-level waste

  9. Weather from 250 Miles Up: Visualizing Precipitation Satellite Data (and Other Weather Applications) Using CesiumJS

    Science.gov (United States)

    Lammers, Matt

    2017-01-01

    Geospatial weather visualization remains predominately a two-dimensional endeavor. Even popular advanced tools like the Nullschool Earth display 2-dimensional fields on a 3-dimensional globe. Yet much of the observational data and model output contains detailed three-dimensional fields. In 2014, NASA and JAXA (Japanese Space Agency) launched the Global Precipitation Measurement (GPM) satellite. Its two instruments, the Dual-frequency Precipitation Radar (DPR) and GPM Microwave Imager (GMI) observe much of the Earth's atmosphere between 65 degrees North Latitude and 65 degrees South Latitude. As part of the analysis and visualization tools developed by the Precipitation Processing System (PPS) Group at NASA Goddard, a series of CesiumJS [Using Cesium Markup Language (CZML), JavaScript (JS) and JavaScript Object Notation (JSON)] -based globe viewers have been developed to improve data acquisition decision making and to enhance scientific investigation of the satellite data. Other demos have also been built to illustrate the capabilities of CesiumJS in presenting atmospheric data, including model forecasts of hurricanes, observed surface radar data, and gridded analyses of global precipitation. This talk will present these websites and the various workflows used to convert binary satellite and model data into a form easily integrated with CesiumJS.

  10. Dosimetry of a Cesium 137 source

    International Nuclear Information System (INIS)

    Torres R, J.G.; Manzanares A, E.; Vega C, H.R.

    2005-01-01

    It was carried out a dosimetric study of a source of Cesium 137 used in investigations of Radiobiology. This radionuclide has a half life of 30.07 years and it emits photons of 661.657 keV with a probability of 85.2%. The source has been used in a series of experiments trending to observe the cellular response before the gamma rays, as well as for the calibration of equipment of radiological protection. For such reason it is important to determine the dosimetric properties. In this work it was determined the absorbed dose that this source takes when being placed in the center from a methylmethacrylate badge to three distances, 5, 10 and 15 cm. The dose was measured with thermoluminescent dosemeters and it was calculated by means of Monte Carlo method, also was derived an expression that allows to determine the dose starting from the information of the activity of the source and of the distance regarding the same one. (Author)

  11. Rotman lens for mm-wavelengths

    Science.gov (United States)

    Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek

    2002-11-01

    The 77 GHz band has been reserved for intelligent cruise control in luxury cars and some public transport services in America and the United Kingdom. The Rotman lens offers a cheap and compact means to extend the single beam systems generally used, to fully functional beam staring arrangements. Rotman lenses have been built for microwave frequencies with limited success. The flexibility of microstrip transmission lines and the advent of fast accurate simulation packages allow practical Rotman lenses to be designed at mm-wavelengths. This paper discusses the limitations of the conventional design approach and predicts the performance of a new Rotman lens designed at 77 GHz.

  12. Developing the Regulatory Utility of the Exposome: Mapping Exposures for Risk Assessment through Lifestage Exposome Snapshots (LEnS).

    Science.gov (United States)

    Shaffer, Rachel M; Smith, Marissa N; Faustman, Elaine M

    2017-08-07

    Exposome-related efforts aim to document the totality of human exposures across the lifecourse. This field has advanced rapidly in recent years but lacks practical application to risk assessment, particularly for children's health. Our objective was to apply the exposome to children's health risk assessment by introducing the concept of Lifestage Exposome Snapshots (LEnS). Case studies are presented to illustrate the value of the framework. The LEnS framework encourages organization of exposome studies based on windows of susceptibility for particular target organ systems. Such analyses will provide information regarding cumulative impacts during specific critical periods of the life course. A logical extension of this framework is that regulatory standards should analyze exposure information by target organ, rather than for a single chemical only or multiple chemicals grouped solely by mechanism of action. The LEnS concept is a practical refinement to the exposome that accounts for total exposures during particular windows of susceptibility in target organ systems. Application of the LEnS framework in risk assessment and regulation will improve protection of children's health by enhancing protection of sensitive developing organ systems that are critical for lifelong health and well-being. https://doi.org/10.1289/EHP1250.

  13. Measurements of cesium and strontium diffusion in biotite gneiss

    International Nuclear Information System (INIS)

    Skagius, K.; Neretnieks, I.

    1988-01-01

    A significant retardation of radionuclides transported by flowing water from an underground repository can be expected if the nuclides are able to diffuse into the water filled micropores in the rock. This diffusion into the pores will also increase the surface available to interactions between the nuclides in the ground water and the rock material, such as sorption. To calculate the retardation, it is necessary to know the sorption properties and the diffusivities in the rock matrix for the radionuclides. Diffusion experiments with cesium and strontium in biotite gneiss samples have been performed. Both the transport of strontium and cesium through rock samples and the concentration profiles of cesium and strontium inside rock samples have been determined. The result shows that diffusion of cesium and strontium occurs in the rock material. A diffusion model has been used to evaluate the diffusivity. Both pore diffusion and surface diffusion had to be included in the model to give good agreement with the experimental data. If surface diffusion is not included in the model, the effective pore diffusivity that gives the best fit to the experimental data is found to be higher than expected from earlier measurement of iodide diffusion in the same type of rock material. This indicates that the diffusion of cesium and strontium (sorbing components) in rock material is caused by both pore diffusion and surface diffusion acting in parallel

  14. Accumulation of strontium 90 and cesium 137 in some hydrobionts

    International Nuclear Information System (INIS)

    Boyadzhiev, A.; Keslev, D.; Kerteva, A.; Novakova, E.

    1974-01-01

    Factors responsible for the accumulation of strontium 90 and cesium 137 in some plant organisms, characteristic for fishes in Bulgarian fresh-water reservoirs and in Black Seawater, were examined. The investigated samples were taken during spring, summer and autumn-winter seasons 1967/1968. Each sample burnt to ashes at 450 0 C was examined for strontium 90 and cesium 137 content as well as stable isotopes of calcuim and potassium. Accumulation factors for strontium 90 and cesium 137 were significantly higher in freshwater hydrobionts than in seawater hydrobionts. This could be explained by variations in the concentration of stable isotopes of calcium and potassium from freshwater reservoirs and from seawater. Potassium and calcium concentrations were relatively constant in seawater while in freshwater they were significantly variable. Accumulation factors for these radionuclides increased according to the amount of rain and the altitude above sea level. Strontium 90 was deposited mostly in fins, less in scales and least in the meat of fishes; cesium 137 was mainly deposited in the meat and less in the other parts of fishes. The highest accumulation factors for strontium 90 were determined in fishes and for cesium 137 in plant organisms. The most convenient plant and fish species for tracing radioactive contamination of freshwater reservoirs and in the Black Sea were indicated. (A.B.)

  15. T1 nuclear magnetic relaxation dispersion of hyperpolarized sodium and cesium hydrogencarbonate-13 C.

    Science.gov (United States)

    Martínez-Santiesteban, Francisco M; Dang, Thien Phuoc; Lim, Heeseung; Chen, Albert P; Scholl, Timothy J

    2017-09-01

    In vivo pH mapping in tissue using hyperpolarized hydrogencarbonate- 13 C has been proposed as a method to study tumor growth and treatment and other pathological conditions related to pH changes. The finite spin-lattice relaxation times (T 1 ) of hyperpolarized media are a significant limiting factor for in vivo imaging. Relaxation times can be measured at standard magnetic fields (1.5 T, 3.0 T etc.), but no such data are available at low fields, where T 1 values can be significantly shorter. This information is required to determine the potential loss of polarization as the agent is dispensed and transported from the polarizer to the MRI scanner. The purpose of this study is to measure T 1 dispersion from low to clinical magnetic fields (0.4 mT to 3.0 T) of different hyperpolarized hydrogencarbonate formulations previously proposed in the literature for in vivo pH measurements. 13 C-enriched cesium and sodium hydrogencarbonate preparations were hyperpolarized using dynamic nuclear polarization, and the T 1 values of different samples were measured at different magnetic field strengths using a fast field-cycling relaxometer and a 3.0 T clinical MRI system. The effects of deuterium oxide as a dissolution medium for sodium hydrogencarbonate were also analyzed. This study finds that the cesium formulation has slightly shorter T 1 values compared with the sodium preparation. However, the higher solubility of cesium hydrogencarbonate- 13 C means it can be polarized at greater concentration, using less trityl radical than sodium hydrogencarbonate- 13 C. This study also establishes that the preparation and handling of sodium hydrogencarbonate formulations in relation to cesium hydrogencarbonate is more difficult, due to the higher viscosity and lower achievable concentrations, and that deuterium oxide significantly increases the T 1 of sodium hydrogencarbonate solutions. Finally, this work also investigates the influence of pH on the spin-lattice relaxation of cesium

  16. Simultaneous Scanning Electron Microscope Imaging of Topographical and Chemical Contrast Using In-Lens, In-Column, and Everhart-Thornley Detector Systems.

    Science.gov (United States)

    Zhang, Xinming; Cen, Xi; Ravichandran, Rijuta; Hughes, Lauren A; van Benthem, Klaus

    2016-06-01

    The scanning electron microscope provides a platform for subnanometer resolution characterization of material morphology with excellent topographic and chemical contrast dependent on the used detectors. For imaging applications, the predominantly utilized signals are secondary electrons (SEs) and backscattered electrons (BSEs) that are emitted from the sample surface. Recent advances in detector technology beyond the traditional Everhart-Thornley geometry have enabled the simultaneous acquisition and discrimination of SE and BSE signals. This study demonstrates the imaging capabilities of a recently introduced new detector system that consists of the combination of two in-lens (I-L) detectors and one in-column (I-C) detector. Coupled with biasing the sample stage to reduce electron-specimen interaction volumes, this trinity of detector geometry allows simultaneous acquisition of signals to distinguish chemical contrast from topographical changes of the sample, including the identification of surface contamination. The I-C detector provides 4× improved topography, whereas the I-L detector closest to the sample offers excellent simultaneous chemical contrast imaging while not limiting the minimization of working distance to obtain optimal lateral resolution. Imaging capabilities and contrast mechanisms for all three detectors are discussed quantitatively in direct comparison to each other and the conventional Everhart-Thornley detector.

  17. Primary standardization of cesium-137 for international intercomparison

    International Nuclear Information System (INIS)

    Srivastava, P.K.

    1977-01-01

    Primary standards of cesium-137 are of great importance for precise radiation measurements because, due to its simple decay-scheme and long half-life, it is widely used for the calibration of radiation detectors. Also 137 Cs is used for the measurement of fission-yield and uranium burn-up in reactor engineering studies. In view of these, an international intercomparison was organised on a limited scale to correlate the standards established at the Bhabha Atomic Research Centre (BARC), Bombay(India) and Physikalisch-Technische Bundesanstalt (PTB), West Germany. The ''efficiency tracing technique'' was developed at BARC for the primary standardization of 137 Cs for this intercomparison. Two tracers, namely 82 Br and 60 Co, were employed to trace the beta efficiency of the 4 πβ-γ coincidence counting system. It is shown that this technique offers high accuracy and inherent reliability. The ''tracing-technique'' for 137 Cs standardization is briefly described. The gravimetric method of dilution and preparation of mixed sources of 137 Cs - 82 Br and 137 Cs - 60 Co are given. The various counting parameters and settings are included. Data reduction and the estimation of systematic and statistical errors are discussed. The results of the intercomparison, which are also included, show that the agreement between the measurments of BARC and PTB is within 0.5%. (author)

  18. International survey of contact lens prescribing for extended wear.

    Science.gov (United States)

    Efron, Nathan; Morgan, Philip B; Woods, Craig A

    2012-02-01

    To determine the extent of extended wear (EW) contact lens prescribing worldwide and to characterize the associated demographics and fitting patterns. Up to 1000 survey forms were sent to contact lens fitters in up to 39 countries between January and March every year for five consecutive years (2006-2010). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Survey data collected since 1997 was also analyzed to assess EW fitting trends since that time. Details for lens modality were received for 107,094 rigid and soft lens fits of which 88,392 were for soft lens daily wear (DW) and 7470 were for soft lens EW. Overall, EW represents 7.8% of all soft lens fits, ranging from 0.6% in Malaysia to 27% Norway. Compared with DW fittings, EW fittings can be characterized as follows: older age (32.7 ± 13.6 vs. 29.4 ± 12.0 years for DW); males are over-represented; greater proportion of refits; 72% silicone hydrogel; higher proportion of presbyopia and spherical designs; and higher proportion of monthly lens replacement. Of those wearing EW lenses, 80% use multipurpose solutions, whereas 9% do not use any care system. Between 1997 and 1999, the rate of EW prescribing decreased from 5 to 1% of all soft lens fits; it increased to a peak of 12% in 2006, and settled back to 8% by 2010. EW prescribing has failed to break through the "glass ceiling" of 15% and is unlikely to become a mainstream lens wearing modality until the already low risks of ocular complications can be reduced to be equivalent to that for DW.

  19. [Correct contact lens hygiene].

    Science.gov (United States)

    Blümle, S; Kaercher, T; Khaireddin, R

    2013-06-01

    Although contact lenses have long been established in ophthalmology, practical aspects of handling contact lenses is becoming increasingly less important in the clinical training as specialist for ophthalmology. Simultaneously, for many reasons injuries due to wearing contact lenses are increasing. In order to correct this discrepancy, information on contact lenses and practical experience with them must be substantially increased from a medical perspective. This review article deals with the most important aspects for prevention of complications, i.e. contact lens hygiene.

  20. Removal of cesium ions from clays by cationic surfactant intercalation.

    Science.gov (United States)

    Park, Chan Woo; Kim, Bo Hyun; Yang, Hee-Man; Seo, Bum-Kyoung; Moon, Jei-Kwon; Lee, Kune-Woo

    2017-02-01

    We propose a new approach to remediate cesium-contaminated clays based on intercalation of the cationic surfactant dodecyltrimethylammonium bromide (DTAB) into clay interlayers. Intercalation of DTAB was found to occur very rapidly and involved exchanging interlayer cations. The reaction yielded efficient cesium desorption (∼97%), including of a large amount of otherwise non-desorbable cesium ions by cation exchange with ammonium ions. In addition, the intercalation of DTAB afforded an expansion of the interlayers, and an enhanced desorption of Cs by cation exchange with ammonium ions even at low concentrations of DTAB. Finally, the residual intercalated surfactants were easily removed by a decomposition reaction with hydrogen peroxide in the presence of Cu 2+ /Fe 2+ catalysts. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Controllable evaporation of cesium from a dispenser oven.

    Science.gov (United States)

    Fantz, U; Friedl, R; Fröschle, M

    2012-12-01

    This instrument allows controlled evaporation of the alkali metal cesium over a wide range of evaporation rates. The oven has three unique features. The first is an alkali metal reservoir that uses a dispenser as a cesium source. The heating current of the dispenser controls the evaporation rate allowing generation of an adjustable and stable flow of pure cesium. The second is a blocking valve, which is fully metallic as is the body of the oven. This construction both reduces contamination of the dispenser and enables the oven to be operated up to 300 °C, with only small temperature variations (dispenser oven can be easily transferred to the other alkali-metals.

  2. Sorption kinetics of cesium on hydrous titanium dioxide

    International Nuclear Information System (INIS)

    Altas, Y.; Tel, H.; Yaprak, G.

    2003-01-01

    Two types of hydrous titanium dioxide possessing different surface properties were prepared and characterized to study the sorption kinetics of cesium. The effect of pH on the adsorption capacity were determined in both type sorbents and the maximum adsorption percentage of cesium were observed at pH 12. To elucidate the kinetics of ion-exchange reaction on hydrous titanium dioxide, the isotopic exchange rates of cesium ions between hydrous titanium dioxides and aqueous solutions were measured radiochemically and compared with each other. The diffusion coefficients of Cs + ion for Type1 and Type2 titanium dioxides at pH 12 were calculated as 2.79 x 10 -11 m 2 s -1 and 1.52 x 10 -11 m 2 s -1 , respectively, under particle diffusion controlled conditions. (orig.)

  3. Cesium 137 in oils and plants from Guatemala

    International Nuclear Information System (INIS)

    Ayala, R.E.; Perez, J.F.

    1993-01-01

    Since 1990 the project of radioactive and environmental contamination started in Guatemala. Studies about the radioactive contamination levels are made within the framework of this project. Cesium-137 has been an interest radionuclide, because it is a fission product released to the environment by the use of nuclear weapons and nuclear power plants accidents. The sampling consisted in collection of soil and grass in 20 provinces of Guatemala, one point by province, and it was made in 1990. The cesium-137 concentration in the samples, was determined by gamma spectrometry, using an hyper pure germanium detector. The results show the presence of radioactive contamination in soil and grass due to cesium-137, at levels that might be considered as normal. The levels found are not harmful for human health, and its importance is the fact that can be used as reference levels for the environmental radioactivity monitoring in Guatemala

  4. Cesium in the Savannah River Site environment

    Energy Technology Data Exchange (ETDEWEB)

    Carlton, W.H.; Bauer, L.R.; Evans, A.G.; Geary, L.A.; Murphy, C.E. Jr.; Pinder, J.E.; Strom, R.N.

    1992-03-01

    Cesium in the Savannah River Site Environment is published as a part of the Radiological Assessment Program (RAP). It is the fourth in a series of eight documents on individual radioisotopes released to the environment as a result of Savannah River Site (SRS) operations. The earlier documents describe the environmental consequences of tritium, iodine, and uranium. Documents on plutonium, strontium, carbon, and technetium will be published in the future. These are dynamic documents and current plans call for revising and updating each one on a two-year schedule.Radiocesium exists in the environment as a result of above-ground nuclear weapons tests, the Chernobyl accident, the destruction of satellite Cosmos 954, small releases from reactors and reprocessing plants, and the operation of industrial, medical, and educational facilities. Radiocesium has been produced at SRS during the operation of five production reactors. Several hundred curies of [sup 137]Cs was released into streams in the late 50s and 60s from leaking fuel elements. Smaller quantities were released from the fuel reprocessing operations. About 1400 Ci of [sup 137]Cs was released to seepage basins where it was tightly bound by clay in the soil. A much smaller quantity, about four Ci. was released to the atmosphere. Radiocesium concentration and mechanisms for atmospheric, surface water, and groundwater have been extensively studied by Savannah River Technology Center (SRTC) and ecological mechanisms have been studied by Savannah River Ecology Laboratory (SREL). The overall radiological impact of SRS releases on the offsite maximum individual can be characterized by total doses of 033 mrem (atmospheric) and 60 mrem (liquid), compared with a dose of 12,960 mrem from non-SRS sources during the same period of time. Isotope [sup 137]Cs releases have resulted in a negligible risk to the environment and the population it supports.

  5. Cesium in the Savannah River Site environment

    Energy Technology Data Exchange (ETDEWEB)

    Carlton, W.H.; Bauer, L.R.; Evans, A.G.; Geary, L.A.; Murphy, C.E. Jr.; Pinder, J.E.; Strom, R.N.

    1992-03-01

    Cesium in the Savannah River Site Environment is published as a part of the Radiological Assessment Program (RAP). It is the fourth in a series of eight documents on individual radioisotopes released to the environment as a result of Savannah River Site (SRS) operations. The earlier documents describe the environmental consequences of tritium, iodine, and uranium. Documents on plutonium, strontium, carbon, and technetium will be published in the future. These are dynamic documents and current plans call for revising and updating each one on a two-year schedule.Radiocesium exists in the environment as a result of above-ground nuclear weapons tests, the Chernobyl accident, the destruction of satellite Cosmos 954, small releases from reactors and reprocessing plants, and the operation of industrial, medical, and educational facilities. Radiocesium has been produced at SRS during the operation of five production reactors. Several hundred curies of {sup 137}Cs was released into streams in the late 50s and 60s from leaking fuel elements. Smaller quantities were released from the fuel reprocessing operations. About 1400 Ci of {sup 137}Cs was released to seepage basins where it was tightly bound by clay in the soil. A much smaller quantity, about four Ci. was released to the atmosphere. Radiocesium concentration and mechanisms for atmospheric, surface water, and groundwater have been extensively studied by Savannah River Technology Center (SRTC) and ecological mechanisms have been studied by Savannah River Ecology Laboratory (SREL). The overall radiological impact of SRS releases on the offsite maximum individual can be characterized by total doses of 033 mrem (atmospheric) and 60 mrem (liquid), compared with a dose of 12,960 mrem from non-SRS sources during the same period of time. Isotope {sup 137}Cs releases have resulted in a negligible risk to the environment and the population it supports.

  6. Cesium in the Savannah River Site environment

    International Nuclear Information System (INIS)

    Carlton, W.H.; Bauer, L.R.; Evans, A.G.; Geary, L.A.; Murphy, C.E. Jr.; Pinder, J.E.; Strom, R.N.

    1992-03-01

    Cesium in the Savannah River Site Environment is published as a part of the Radiological Assessment Program (RAP). It is the fourth in a series of eight documents on individual radioisotopes released to the environment as a result of Savannah River Site (SRS) operations. The earlier documents describe the environmental consequences of tritium, iodine, and uranium. Documents on plutonium, strontium, carbon, and technetium will be published in the future. These are dynamic documents and current plans call for revising and updating each one on a two-year schedule.Radiocesium exists in the environment as a result of above-ground nuclear weapons tests, the Chernobyl accident, the destruction of satellite Cosmos 954, small releases from reactors and reprocessing plants, and the operation of industrial, medical, and educational facilities. Radiocesium has been produced at SRS during the operation of five production reactors. Several hundred curies of 137 Cs was released into streams in the late 50s and 60s from leaking fuel elements. Smaller quantities were released from the fuel reprocessing operations. About 1400 Ci of 137 Cs was released to seepage basins where it was tightly bound by clay in the soil. A much smaller quantity, about four Ci. was released to the atmosphere. Radiocesium concentration and mechanisms for atmospheric, surface water, and groundwater have been extensively studied by Savannah River Technology Center (SRTC) and ecological mechanisms have been studied by Savannah River Ecology Laboratory (SREL). The overall radiological impact of SRS releases on the offsite maximum individual can be characterized by total doses of 033 mrem (atmospheric) and 60 mrem (liquid), compared with a dose of 12,960 mrem from non-SRS sources during the same period of time. Isotope 137 Cs releases have resulted in a negligible risk to the environment and the population it supports

  7. Thermal Performance Analysis For Small Ion-Exchange Cesium Removal Process

    International Nuclear Information System (INIS)

    Lee, S.; King, W.

    2009-01-01

    The In-Riser Ion Exchange program focuses on the development of in-tank systems to decontaminate high level waste (HLW) salt solutions at the Savannah River Site (SRS) and the Hanford Site. Small Column Ion Exchange (SCIX) treatment for cesium removal is a primary in-riser technology for decontamination prior to final waste immobilization in Saltstone. Through this process, radioactive cesium from the salt solution is adsorbed onto the ion exchange media which is packed within a flow-through column. Spherical Resorcinol-Formaldehyde (RF) is being considered as the ion exchange media for the application of this technology at both sites. A packed column loaded with media containing radioactive cesium generates significant heat from radiolytic decay. Under normal operating conditions, process fluid flow through the column can provide adequate heat removal from the columns. However, in the unexpected event of loss of fluid flow or fluid drainage from the column, the design must be adequate to handle the thermal load to avoid unacceptable temperature excursions. Otherwise, hot spots may develop locally which could degrade the performance of the ion-exchange media or the temperature could rise above column safety limits. Data exists which indicates that performance degradation with regard to cesium removal occurs with RF at 65C. In addition, the waste supernate solution will boil around 130C. As a result, two temperature limits have been assumed for this analysis. An additional upset scenario was considered involving the loss of the supernate solution due to inadvertent fluid drainage through the column boundary. In this case, the column containing the loaded media could be completely dry. This event is expected to result in high temperatures that could damage the column or cause the RF sorbent material to undergo undesired physical changes. One objective of these calculations is to determine the range of temperatures that should be evaluated during testing with the RF

  8. Design of LED projector based on gradient-index lens

    Science.gov (United States)

    Qian, Liyong; Zhu, Xiangbing; Cui, Haitian; Wang, Yuanhang

    2018-01-01

    In this study, a new type of projector light path is designed to eliminate the deficits of existing projection systems, such as complex structure and low collection efficiency. Using a three-color LED array as the lighting source, by means of the special optical properties of a gradient-index lens, the complex structure of the traditional projector is simplified. Traditional components, such as the color wheel, relay lens, and mirror, become unnecessary. In this way, traditional problems, such as low utilization of light energy and loss of light energy, are solved. With the help of Zemax software, the projection lens is optimized. The optimized projection lens, LED, gradient-index lens, and digital micromirror device are imported into Tracepro. The ray tracing results show that both the utilization of light energy and the uniformity are improved significantly.

  9. Planar optical correlators integrated with binary optical lens.

    Science.gov (United States)

    Xu, Ping; Hong, Chunquan; Cheng, Guanxiao; Zhou, Liang; Sun, Zhilong

    2015-03-09

    Planar optical correlators (POCs) can achieve smaller volume of optical system and hence have important applications to identify dynamic targets in complex scenarios. POCs, however, generally have serious astigmatism and optical efficiency loss introduced by its refractive lens with a zigzag optical beam. To conquer the disadvantages of POCs, we propose a type of binary optical planar-integrated optical correlator. The correlator incorporates two pieces of reflective binary optical lens as Fourier transform lens and one spatial light modulator as a programmable filter. The off-axis aberrations commonly occurred in POCs can be corrected by using reflective binary optical lens instead of refractive lens. As a model of hybrid numerical-optical correlator using optoelectronic interface, the proposal is helpful to improve the integration and flexibility and robustness of POCs.

  10. Dielectrically embedded flat mesh lens for millimeter waves applications.

    Science.gov (United States)

    Pisano, Giampaolo; Ng, Ming Wah; Ozturk, Fahri; Maffei, Bruno; Haynes, Vic

    2013-04-10

    A flat lens based on subwavelength periodic metal meshes has been developed using photolithographic techniques. These mesh grids are stacked at specific distances and embedded in polypropylene. A code was developed to optimize more than 1000 transmission line circuits required to vary the device phase shift across the lens flat surface, mimicking the behavior of a classical lens. A W-band mesh-lens prototype was successfully manufactured and its RF performance characterized using a vector network analyzer coupled to corrugated horn antennas. Co-polarization far-field beam patterns were measured and compared with finite-element method models. The excellent agreement between data and simulations validated our designing tools and manufacturing procedures. This mesh lens is a low-loss, robust, light, and compact device that has many potential applications including millimeter wave quasi-optical systems for future cosmic microwave background polarization instruments.

  11. Sericitization of illite decreases sorption capabilities for cesium

    Science.gov (United States)

    Choung, S.; Hwang, J.; Han, W.; Shin, W.

    2017-12-01

    Release of radioactive cesium (137Cs) to environment occurs through nuclear accidents such as Chernobyl and Fukushima. The concern is that 137Cs has long half-life (t1/2 = 30.2 years) with chemical toxicity and γ-radiation. Sorption techniques are mainly applied to remove 137Cs from aquatic environment. In particular, it has been known well that clay minerals (e.g, illite) are effective and economical sorbents for 137Cs. Illite that was formed by hydrothermal alteration exist with sericite through "sericitization" processes. Although sericite has analogous composition and lattice structure with illite, the sorptive characteristics of illite and sericite for radiocesium could be different. This study evaluated the effects of hydrothermal alteration and weathering process on illite cesium sorption properties. Natural illite samples were collected at Yeongdong area in Korea as the world-largest hydrothermal deposits for illite. The samples were analyzed by XRF, XRD and SEM-EDX to determine mineralogy, chemical compositions and morphological characteristics, and used for batch sorption experiments. The Yeongdong illites predominantly consist of illite, sericite, quartz, and albite. The measured cesium sorption distribution coefficients (Kd,Cs) of reference illite and sericite were approximately 6000 and 400 L kg-1 at low aqueous concentration (Cw 10-7 M), respectively. In contrast, Kd,Cs values for the Yeongdong illite samples ranged from 500 to 4000 L kg-1 at identical concentration. The observed narrow and sharp XRD peak of sericite indicated that the sericite has better crystallinity compared to illite. These experimental results suggested that sericitization processes of illite can decline the sorption capabilities of illite for cesium under various hydrothermal conditions. In particular, weathering experiments raised the cesium sorption to illite, which seems to be related to the increase of preferential sorption sites for cesium through crystallinity destruction

  12. An adjustable electron achromat for cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M., E-mail: rtromp@us.ibm.com [IBM T.J. Watson Research Center, 1101 Kitchawan Road, Yorktown Heights, NY 10598 (United States); Leiden Institute of Physics, Kamerlingh Onnes Laboratory, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-12-15

    Chromatic aberration correction in light optics began with the invention of a two-color-corrected achromatic crown/flint lens doublet by Chester Moore Hall in 1730. Such color correction is necessary because any single glass shows dispersion (i.e. its index of refraction changes with wavelength), which can be counteracted by combining different glasses with different dispersions. In cathode lens microscopes (such as Photo Electron Emission Microscopy – PEEM) we encounter a similar situation, where the chromatic aberration coefficient of the cathode lens shows strong dispersion, i.e. depends (non-linearly) on the energy with which the electrons leave the sample. Here I show how a cathode lens in combination with an electron mirror can be configured as an adjustable electron achromat. The lens/mirror combination can be corrected at two electron energies by balancing the settings of the electron mirror against the settings of the cathode lens. The achromat can be adjusted to deliver optimum performance, depending on the requirements of a specific experiment. Going beyond the achromat, an apochromat would improve resolution and transmission by a very significant margin. I discuss the requirements and outlook for such a system, which for now remains a wish waiting for fulfilment. - Highlights: • The properties of cathode objective lens plus electron mirror are discussed. • In analogy with light-optical achromats, cathode lens plus mirror can be configured as an electron achromat. • Unlike light optics, the electron achromat can be adjusted to best fulfill experimental requirements.

  13. THE BOSS EMISSION-LINE LENS SURVEY. IV. SMOOTH LENS MODELS FOR THE BELLS GALLERY SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Yiping [National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, Chaoyang District, Beijing 100012 (China); Bolton, Adam S.; Montero-Dorta, Antonio D.; Cornachione, Matthew A.; Zheng, Zheng; Brownstein, Joel R. [Department of Physics and Astronomy, University of Utah, 115 South 1400 East, Salt Lake City, UT 84112 (United States); Mao, Shude [Physics Department and Tsinghua Centre for Astrophysics, Tsinghua University, Beijing 100084 (China); Kochanek, Christopher S. [Department of Astronomy and Center for Cosmology and Astroparticle Physics, Ohio State University, Columbus, OH 43210 (United States); Pérez-Fournon, Ismael; Marques-Chaves, Rui [Instituto de Astrofísica de Canarias, C/Vía Láctea, s/n, E-38205 San Cristóbal de La Laguna, Tenerife (Spain); Oguri, Masamune [Research Center for the Early Universe, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Ménard, Brice, E-mail: yiping.shu@nao.cas.cn [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218 (United States)

    2016-12-20

    We present Hubble Space Telescope F606W-band imaging observations of 21 galaxy-Ly α emitter lens candidates in the Baryon Oscillation Spectroscopic Survey Emission-Line Lens Survey (BELLS) for the GALaxy-Ly α EmitteR sYstems (BELLS GALLERY) survey. Seventeen systems are confirmed to be definite lenses with unambiguous evidence of multiple imaging. The lenses are primarily massive early-type galaxies (ETGs) at redshifts of approximately 0.55, while the lensed sources are Ly α emitters (LAEs) at redshifts from two to three. Although most of the lens systems are well fit by smooth lens models consisting of singular isothermal ellipsoids in an external shear field, a thorough exploration of dark substructures in the lens galaxies is required. The Einstein radii of the BELLS GALLERY lenses are, on average, 60% larger than those of the BELLS lenses because of the much higher source redshifts. This will allow for a detailed investigation of the radius evolution of the mass profile in ETGs. With the aid of the average ∼13× lensing magnification, the LAEs are frequently resolved into individual star-forming knots with a wide range of properties. They have characteristic sizes from less than 100 pc to several kiloparsecs, rest-frame far-UV apparent AB magnitudes from 29.6 to 24.2, and typical projected separations of 500 pc to 2 kpc.

  14. Different effects of the hypolipidemic drugs pravastatin and lovastatin on the cholesterol biosynthesis of the human ocular lens in organ culture and on the cholesterol content of the rat lens in vivo

    NARCIS (Netherlands)

    Vries, A.C.J. de; Cohen, L.H.

    1993-01-01

    This study aimed to investigate the influence of the hypocholesterolemic drugs pravastatin and lovastatin on the cholesterol biosynthesis in the ocular lens. Two model systems were used: a human lens organ culture system and an in vivo rat lens system. For measurements of cholesterol and fatty acid

  15. Prolonging contact lens wear and making contact lens wear safer.

    Science.gov (United States)

    Foulks, Gary N

    2006-02-01

    To summarize the present status of safety and efficacy of contact lens wear. Literature review. Ovid Medline searches were performed on records from 1966 through 2005 using keywords: keratitis, contact lens complications, extended-wear contact lenses, and silicone-hydrogel contact lenses. Patients desire comfort, clarity of vision, and prolonged contact lens wear when contact lenses are used to correct refractive error. Practitioners desire patient satisfaction but also require maintenance of the integrity of the eye and no complications that jeopardize vision or health of the eye. Improvements in the oxygen permeability of the contact lens materials, design of the contact lens and its surface, and solutions for the maintenance of the lens have reduced but not eliminated the risks of infection, inflammation, and conjunctival papillary reaction associated with contact lens wear. The lessons of past and recent history suggest that patient education and practitioner participation in the management of contact lens wear continue to be critical factors for patient satisfaction and safety in the extended wear of contact lenses. The availability of highly oxygen permeable contact lenses has increased the tolerance and safety of extended contact lens wear, but patient instruction and education in proper use and care of lenses is required and caution is advised.

  16. Adsorption of iodine and cesium onto some cement materials

    Energy Technology Data Exchange (ETDEWEB)

    Mine, Tatsuya [Mitsui Shipbuilding and Engineering Co. Ltd., Tokyo (Japan); Mihara, Morihiro; Ito, Masaru [Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works; Kato, Hiroshige [IDC, Tokai, Ibaraki (Japan)

    1997-06-01

    Cement materials, being expected to be used in structural materials in underground disposals of radioactive wastes, may adsorb nuclides resulting in retardation of their migration in environment. In this report adsorption behaviors of cement pastes toward iodine (as anion) and cesium (as cation) were studied. Adsorption of iodine was remarkable for OPC and MHP pastes that are known to have high molar ratio CaO/SiO{sub 2}, partition coefficient being 100 ml/g for initial tracer concentration of 10{sup -5} mol/l. Partition coefficient for cesium for PFA paste was found to be 5 ml/g on average. (S. Ohno)

  17. Strontium-90 and cesium-137 in freshwater from May 1984

    International Nuclear Information System (INIS)

    1984-01-01

    Strontium-90 and cesium-137 in freshwater measured in May 1984 are given in pCi/l. The sampling point is 1, Kasumigaura-Lake (Ibaraki). Collection and pretreatment of samples, preparation of samples for analysis, separation of strontium-90 and cesium-137, determination of stable strontium, calcium and potassium, and counting are described. The sample was passed through a cation exchange column. After the radiochemical separation, the mounted precipitates were counted for activity using low background beta counters normally for 60 minutes. (Mori, K.)

  18. Cesium-137: psychological and social consequences of the Goiania's accident

    International Nuclear Information System (INIS)

    Helou, Suzana; Costa Neto, Sebastiao Benicio da

    1995-01-01

    The book care for radioactive accident occurred in 1987 in Goiania - brazilian city. The accident had origin by the hospitable equipment incorrect handling which contained a stainless steel capsule, in which interior there was cesium-137 chloride. The main boarded aspects are: psychological and social aspects verified after the accident; psychological and social analysis of population of Goiania three years after the accident; essay on the pertinence of Luscher's abbreviate test in psychological evaluation of the radioactive accident victims of Goiania; and psychological and mobile evaluation of intra-uterus children exposed to the radiation with cesium-137

  19. School Systems' Practices of Controlling Socialization during Principal Succession: Looking through the Lens of an Organizational Socialization Theory

    Science.gov (United States)

    Bengtson, Ed; Zepeda, Sally J.; Parylo, Oksana

    2013-01-01

    The importance of effective school leadership is well known. The inevitable changing of school leaders raises concerns over the successfulness of the succession process. Directly linked to leader succession is socialization; therefore, the purpose of this study was to examine the processes and practices of school systems that control the…

  20. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  1. Design and analysis of an adaptive lens that mimics the performance of the crystalline lens in the human eye

    Science.gov (United States)

    Santiago-Alvarado, Agustin; Cruz-Félix, Angel S.; Iturbide-Jiménez, F.; Martínez-López, M.; Ramírez-Como, M.; Armengol-Cruz, V.; Vásquez-Báez, I.

    2014-09-01

    Tunable lenses are optical systems that have attracted much attention due to their potential applications in such areas like ophthalmology, machine vision, microscopy and laser processing. In recent years we have been working in the analysis and performance of a liquid-filled variable focal length lens, this is a lens that can modify its focal length by changing the amount of water within it. Nowadays we extend our study to a particular adaptive lens known as solid elastic lens (SEL) that it is formed by an elastic main body made of Polydimethylsiloxane (PDMS Sylgard 184). In this work, we present the design, simulation and analysis of an adaptive solid elastic lens that in principle imitates the accommodation process of the crystalline lens in the human eye. For this work, we have adopted the parameters of the schematic eye model developed in 1985 by Navarro et al.; this model represents the anatomy of the eye as close as possible to reality by predicting an acceptable and accurate quantity of spherical and chromatic aberrations without any shape fitting. An opto-mechanical analysis of the accommodation process of the adaptive lens is presented, by simulating a certain amount of radial force applied onto the SEL using the finite element method with the commercial software SolidWorks®. We also present ray-trace diagrams of the simulated compression process of the adaptive lens using the commercial software OSLO®.

  2. Pilot unit for cesium-137 separation; Unite pilote de separation du cesium-137

    Energy Technology Data Exchange (ETDEWEB)

    Raggenbass, A.; Quesney, M.; Fradin, J.; Dufrene, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Users of radiation are becoming increasingly interested in cesium-137. At the same time the starting up of the industrial plant at Marcoule will make available in the near future large stocks of fission products which should be made use of as quickly as possible. The installation described is a pilot plant for cesium-137 production which should make it possible: - to verify the chemical method on actual solutions of fission products, by treating about 100 curies of {sup 137}Cs by operation, - to obtain technical information on the chemical equipment (tele-commands, corrosion, maintenance, etc...), - to obtain {sup 137}Cs in sufficient quantity to perfect the technique of the manufacture of sealed sources. (author)Fren. [French] L'interet des utilisateurs de rayonnement se porte de plus en plus vers le caesium-137. Parallelement, la mise en oeuvre de l'ensemble industriel de Marcoule nous permettra de disposer dans un avenir proche de stocks importants de produits de fission qu'il sera interessant de valoriser au plus vite. L'installation que nous decrivons est un pilote de production de caesium-137 qui doit nous permettre: - de verifier la methode chimique sur des solutions de produits de fission reelles en traitant environ 100 curies de {sup 137}Cs par operation; - d'obtenir des renseignements techniques sur l'appareillage chimique (telecommandes, corrosion, entretien, etc...); - d'obtenir du {sup 137}Cs en quantite suffisante pour mettre au point la technique de fabrication des sources scellees. (auteur)

  3. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  4. Cesium-134 and strontium-85 turnover rates in the centipede Scolopocryptops nigridia McNeill

    International Nuclear Information System (INIS)

    Yates, L.R.; Crossley, D.A. Jr.

    1979-07-01

    Radioactive tracers are providing significant information about the ecology of food chains, including such phenomena as accumulation of radioactive fission products, movement of materials along food chains, assimilation and ingestion rates, and nutrient accumulation and turnover. In this study the ingestion, assimilation and turnover to two radioactive tracers were investigated for Scolopocryptops nigridia, an abundant species in forests of the southeastern United States. The two tracers utilized, cesium-134 and strontium-85, are metabolic analogs of potassium and calcium, respectively. The research was performed as part of a larger investigation on the population ecology of the centipede species, emphasizing its relations to nutrient cycling and energy flow in a forest floor system

  5. Cesium-134 and strontium-85 turnover rates in the centipede Scolopocryptops nigridia McNeill

    Energy Technology Data Exchange (ETDEWEB)

    Yates, L R; Crossley, Jr, D A

    1979-07-01

    Radioactive tracers are providing significant information about the ecology of food chains, including such phenomena as accumulation of radioactive fission products, movement of materials along food chains, assimilation and ingestion rates, and nutrient accumulation and turnover. In this study the ingestion, assimilation and turnover to two radioactive tracers were investigated for Scolopocryptops nigridia, an abundant species in forests of the southeastern United States. The two tracers utilized, cesium-134 and strontium-85, are metabolic analogs of potassium and calcium, respectively. The research was performed as part of a larger investigation on the population ecology of the centipede species, emphasizing its relations to nutrient cycling and energy flow in a forest floor system.

  6. Precision diagnosis: a view of the clinical decision support systems (CDSS) landscape through the lens of critical care.

    Science.gov (United States)

    Belard, Arnaud; Buchman, Timothy; Forsberg, Jonathan; Potter, Benjamin K; Dente, Christopher J; Kirk, Allan; Elster, Eric

    2017-04-01

    Improving diagnosis and treatment depends on clinical monitoring and computing. Clinical decision support systems (CDSS) have been in existence for over 50 years. While the literature points to positive impacts on quality and patient safety, outcomes, and the avoidance of medical errors, technical and regulatory challenges continue to retard their rate of integration into clinical care processes and thus delay the refinement of diagnoses towards personalized care. We conducted a systematic review of pertinent articles in the MEDLINE, US Department of Health and Human Services, Agency for Health Research and Quality, and US Food and Drug Administration databases, using a Boolean approach to combine terms germane to the discussion (clinical decision support, tools, systems, critical care, trauma, outcome, cost savings, NSQIP, APACHE, SOFA, ICU, and diagnostics). References were selected on the basis of both temporal and thematic relevance, and subsequently aggregated around four distinct themes: the uses of CDSS in the critical and surgical care settings, clinical insertion challenges, utilization leading to cost-savings, and regulatory concerns. Precision diagnosis is the accurate and timely explanation of each patient's health problem and further requires communication of that explanation to patients and surrogate decision-makers. Both accuracy and timeliness are essential to critical care, yet computed decision support systems (CDSS) are scarce. The limitation arises from the technical complexity associated with integrating and filtering large data sets from diverse sources. Provider mistrust and resistance coupled with the absence of clear guidance from regulatory bodies further retard acceptance of CDSS. While challenges to develop and deploy CDSS are substantial, the clinical, quality, and economic impacts warrant the effort, especially in disciplines requiring complex decision-making, such as critical and surgical care. Improving diagnosis in health care

  7. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. [Seoul National University Hospital (Korea, Republic of)

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  8. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  9. Narrative change in emotion-focused therapy: how is change constructed through the lens of the innovative moments coding system?

    Science.gov (United States)

    Mendes, Inês; Ribeiro, António P; Angus, Lynne; Greenberg, Leslie S; Sousa, Inês; Gonçalves, Miguel M

    2010-11-01

    The aim of this study was to advance understanding of how clients construct their own process of change in effective therapy sessions. Toward this end, the authors applied a narrative methodological tool for the study of the change process in emotion-focused therapy (EFT), replicating a previous study done with narrative therapy (NT). The Innovative Moments Coding System (IMCS) was applied to three good-outcome and three poor-outcome cases in EFT for depression to track the innovative moments (IMs), or exceptions to the problematic self-narrative, in the therapeutic conversation. IMCS allows tracking of five types of IMs events: action, reflection, protest, reconceptualization, and performing change. The analysis revealed significant differences between the good-outcome and poor-outcome groups regarding reconceptualization and performing change IMs, replicating the findings from a previous study. Reconceptualization and performing change IMs seem to be vital in the change process.

  10. Caustic-Side Solvent Extraction: Anti-Caking Surfactants Found to be Cause of Apparent Effect of High Nitrite Concentration on Cesium Stripping

    Energy Technology Data Exchange (ETDEWEB)

    Delmau, L.H.

    2002-06-13

    Experiments conducted in FY01 previously indicated a potential cesium stripping problem in the CSSX process due to the presence of nitrite in the waste simulant. The stripping issue seemed all the more important as the nitrite concentration increased. Experiments presented in this work have demonstrated that the true reason for the cesium stripping problem was in fact the presence of an anti-caking agent in the,sodium nitrite. used for the preparation of the simulants. The anti-caking agent is actually a mixture of well-known surfactants, sodium mono- and di-methyl naphthalene sulfonate that can partition into the organic-phase on extraction, then retain cesium upon stripping. The effect was demonstrated by adding known amounts of the anti-caking agent to clean systems. Data suggest that rejuvenation of the solvent can be obtained by a caustic wash following the stripping stage.

  11. Solubility of cesium iodide crystals in aliphatic alchohols

    International Nuclear Information System (INIS)

    Kulikova, N.V.; Kulikov, B.A.

    1988-01-01

    Solubility of cesium iodide crystals in CH 3 OH, C 2 H 5 OH, C 3 H 7 OH, C 4 H 9 OH, C 5 H 11 OH, C 8 H 17 OH aliphatic alcohols at 20, 40, 60 and 80 deg C is determined by conductometric and potentiometric techniques. Equations of solubility correlation with solvent permittivity are presented

  12. Strontium-90 and cesium-137 in fresh water

    International Nuclear Information System (INIS)

    1978-01-01

    Japan Chemical Analysis Center has analysed the strontium-90 and Cesium-137 contents in fresh water from 7 prefectures in Japan by the commission of Science and Technology Agency of Japanese Government. The method described in ''Radioactivity Survey Data in Japan No. 43 (NIRS-RSD-43, 1977) was applied to the analysis of these two radionuclides in samples. (author)

  13. Preparation of cesium targets for gamma-spectroscopic studies

    Science.gov (United States)

    Bhattacharyya, S.; Basu, S. K.; Chanda, S.; Deb, P.; Eqbal, Md; Kundu, S.; Joseph, D.

    2000-11-01

    A procedure to prepare monoisotopic cesium compound targets for gamma-spectroscopic experiments is described. Using this procedure, uniform targets up to thicknesses of 0.6-1.2 mg/cm 2 were prepared and used for in-beam spectroscopic studies. The purity of the target was tested by energy dispersive X-ray fluorescence (EDXRF) measurements.

  14. Fission-product tellurium and cesium telluride chemistry revisited

    International Nuclear Information System (INIS)

    McFarlane, J.; LeBlanc, J.C.

    1996-11-01

    The chemistry of fission-product tellurium is discussed with a focus on conditions in an operating CANDU reactor and in an accident scenario, i.e., a loss of coolant accident (LOCA). Cesium telluride, Cs 2 Te, is likely to be one of the most abundant tellurium species released to containment. Available thermodynamic data on gas phase Cs 2 Te is not complete; hence the volatility of cesium telluride was studied by Knudsen-cell mass spectrometry. Cesium telluride was found to vapourize incongruently, becoming more tellurium-rich in the condensed phase as vapourization progressed. Vapour-phase species that were observed were elemental cesium and tellurium, CsTe, Cs 2 Te, Cs 2 Te 2 and Cs 2 Te 3 . Second-law enthalpies and entropies were obtained for many of these species, and a third-law value, ΔH 298 o , of 186 ± 2 kJ·mol -1 was obtained for Cs 2 Te. (author)

  15. Behaviour of cesium 134 and 137 in lake ecosystems

    International Nuclear Information System (INIS)

    Huebel, K.; Saenger, W.; Luensmann, W.

    1989-01-01

    The time dependent cesium activity concentration observed in surface water samples from South Bavarian lakes after the Chernobyl accident is analysed by use of a two-compartment model simulating the accidental transport of radiocesium from surface water to suspended particles. (orig.)

  16. Cesium-137 accumulation in higher plants before and after Chernobyl

    International Nuclear Information System (INIS)

    Sawidis, T.; Drossos, E.; Papastefanou, C.; Heinrick, G.

    1990-01-01

    Cesium-137 concentrations in plant species of three biotypes of northern Greece, differing in location as well as in vegetation, are reported following the Chernobyl reactor accident. The cesium uptake by plants was due to the foliar deposition rather than the root uptake. The highest level of cesium in plants was found in Ranunculus sardous, a pubescent plant. The 137 Cs concentration was about 22kBq kg -1 d.w. A high level of cesium was also found in Salix alba ( 137 Cs: 19.6 kBq kg -1 d.w.), a deciduous tree showing that hairy leaves or leaves having rough and large surfaces can absorb greater amounts of radioactivity (surface effect). A comparison is also made between the results of measurements of the present study and the results of measurements of some herbarium plants collected one year before the accident as well as the results of measurements of some new plants grown and collected one year after the accident resulting in a natural removal rate of 137 Cs in plants varying from 14 to 130 days

  17. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  18. The Role of Partially-Saturated Conditions, Physical Heterogeneity, and Desorption Kinetics on Colloid-Facilitated Transport of Cesium and Strontium by Illite in Quartz Sand

    Science.gov (United States)

    Dittrich, T. M.; Ryan, J. N.; Saiers, J. E.

    2009-12-01

    In many soil and groundwater systems, colloids are present, mobile, and capable of enhancing the transport of some contaminants if the rate of contaminant desorption from the contaminants is slow relative to the rate of colloid and contaminant transport. The importance of contaminant desorption kinetics has been well illustrated in saturated porous media systems, but not in partially-saturated systems. The goal of this research project was to examine and quantify the effects of contaminant desorption kinetics on colloid-facilitated transport under partially-saturated conditions. Laboratory breakthrough experiments were conducted using a column (12.7 cm diameter and 33.5 cm length) packed with (1) quartz sand of uniform size and (2) quartz sand of two different sizes packed as a central tube simulating a macropore (coarse sand) and surrounding matrix (fine sand). Illite was used as the colloids. Cesium and strontium were chosen as model contaminants because their mechanisms of adsorption to illite result in slower desorption of cesium than of strontium and because these cations are found in their radioactive forms at contaminated Department of Energy sites. In the partially saturated columns of uniform sand, the illite colloids facilitated the transport of both cesium and strontium; however, the transport of cesium was facilitated to a greater extent than strontium because cesium binds strongly to the frayed edge sites on the illite colloids. Compared to saturated conditions, partially-saturated conditions increased the transport of cesium and strontium due to the decreased effective surface area of the quartz sand. At moisture contents near saturation, addition of a macropore increased transport of cesium and strontium due to increased porewater movement through the macropore. At lower moisture contents, less porewater was transported through the macropore and cesium and strontium transport was similar to the uniform sand experiments. A model for colloid

  19. Electrostatic plasma lens for focusing negatively charged particle beams.

    Science.gov (United States)

    Goncharov, A A; Dobrovolskiy, A M; Dunets, S M; Litovko, I V; Gushenets, V I; Oks, E M

    2012-02-01

    We describe the current status of ongoing research and development of the electrostatic plasma lens for focusing and manipulating intense negatively charged particle beams, electrons, and negative ions. The physical principle of this kind of plasma lens is based on magnetic isolation electrons providing creation of a dynamical positive space charge cloud in shortly restricted volume propagating beam. Here, the new results of experimental investigations and computer simulations of wide-aperture, intense electron beam focusing by plasma lens with positive space charge cloud produced due to the cylindrical anode layer accelerator creating a positive ion stream towards an axis system is presented.

  20. Microcrystalline hexagonal tungsten bronze. 1. Basis of ion exchange selectivity for cesium and strontium.

    Science.gov (United States)

    Griffith, Christopher S; Luca, Vittorio; Hanna, John V; Pike, Kevin J; Smith, Mark E; Thorogood, Gordon S

    2009-07-06

    The structural basis of selectivity for cesium and strontium of microcrystalline hexagonal tungsten bronze (HTB) phase Na(x)WO(3+x/2).zH(2)O has been studied using X-ray and neutron diffraction techniques, 1D and 2D (23)Na magic angle spinning (MAS) nuclear magnetic resonance (NMR) spectroscopy, and radiochemical ion exchange investigations. For the HTB system, this study has shown that scattering techniques alone provide an incomplete description of the disorder and rapid exchange of water (with tunnel cations) occurring in this system. However, 1D and 2D (23)Na MAS NMR has identified three sodium species within the HTB tunnels-species A, which is located at the center of the hexagonal window and is devoid of coordinated water, and species B and C, which are the di- and monohydrated variants, respectively, of species A. Although species B accords with the traditional crystallographic model of the HTB phase, this work is the first to propose and identify the anhydrous species A and monohydrate species C. The population (total) of species B and C decreases in comparison to that of species A with increasing exchange of either cesium or strontium; that is, species B and C appear more exchangeable than species A. Moreover, a significant proportion of tunnel water is redistributed by these cations. Multiple ion exchange investigations with radiotracers (137)Cs and (85)Sr have shown that for strontium there is a definite advantage in ensuring that any easily exchanged sodium is removed from the HTB tunnels prior to exchange. The decrease in selectivity (wrt cesium) is most probably due to the slightly smaller effective size of Sr(2+); namely, it is less of a good fit for the hexagonal window, ion exchange site. The selectivity of the HTB framework for cesium has been shown unequivocally to be defined by the structure of the hexagonal window, ion exchange site. Compromising the geometry of this window even in the slightest way by either (1) varying the cell volume through

  1. Functionalized magnetic nanoparticles for the decontamination of water polluted with cesium

    Directory of Open Access Journals (Sweden)

    Ahmed S. Helal

    2016-05-01

    Full Text Available Magnetic nanoparticles are attracting considerable interest because of their potential applications in practically all fields of science and technology, including the removal of heavy metals from contaminated waters. It is, therefore, of great importance to adapt the surfaces of these nanoparticles according to the application. In this work advanced nanoparticles (NPs with well-tailored surface functionalities were synthesized using the polyol method. The efficiency of a chelating agent, succinyl-β-cyclodextrin (SBCD, was first investigated spectrophotometrically and by Isothermal Titration Calorimetry (ITC. SBCD was then grafted onto nanoparticles previously functionalized with 3-aminopropyl triethoxsilane (NP-APTES. The resulting NP-SBCD system was then incubated with a solution of cesium. After magnetic separation, the solid residue was removed from the supernatant and characterized by X-Ray Photoelectron spectrometry (XPS, X-Ray Fluorescence spectrometry (XRF and Superconducting QUantum Interference Device (SQUID magnetometry. These characterizations show the presence of cesium in the solid residue, which indicates Cs uptake by the NP-SBCD system. This nanohybrid system constitutes a promising model for heavy metal decontamination.

  2. Lens dislocation has a possible relationship with laser iridotomy

    Directory of Open Access Journals (Sweden)

    Mutoh T

    2012-12-01

    Full Text Available Tetsuya Mutoh,1,2 Kevin F Barrette,2 Yukihiro Matsumoto,1 Makoto Chikuda11Department of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Koshigaya City, Saitama, Japan; 2Department of Ophthalmology, Boston University School of Medicine, Boston, MA, USAAbstract: We report our recent experience of four eyes with spontaneous lens dislocation in four patients with no history of trauma or any systemic disease associated with zonular dialysis. Lens dislocation developed with 0.5 to 6 months following laser iridotomy. All patients were male and two eyes were complicated with acute primary angle closure glaucoma preoperatively. Case 1 showed bilateral lens dislocation, while cases 2 and 3 involved unilateral lens dislocation. Cases 2 and 3 showed lenses completely dislocated into the vitreous cavity. All cases needed lens removal and scleral fixation of intraocular lenses. Final visual acuity was 1.2 in all cases. We suspect that laser iridotomy may induce localized zonular dialysis that results in progressive zonular weakness, leading to lens dislocation.Keywords: lens dislocation, laser iridotomy, primary angle closure glaucoma

  3. Contact lens surface changes after exposure to surfactant and abrasive cleaning procedures.

    Science.gov (United States)

    Doell, G B; Palombi, D L; Egan, D J; Huff, J W

    1986-06-01

    Proper lens maintenance is required if contact lens wear is to be successful. Poor compliance or inadequate cleaning may lead to contact lens failures and potentially damage to the eye. With phase contrast microscopy, we addressed the effect of cleaning systems on the physical integrity of a surface-modified lens--the Silcon contact lens. Several cleaners were evaluated for their ability to clean Silcon lenses with minimal damage to the lens surface. The data demonstrated that: all cleaning techniques alter the surface appearance; scratches develop more readily on lenses received with surface irregularities; wettability does not correlate with the extent of surface scratching; recommended cleaning procedures do not directly alter the wettability of the contact lens material; and phase contrast microscopy may be a useful addition to laboratory quality control.

  4. Dynamic metasurface lens based on MEMS technology

    Directory of Open Access Journals (Sweden)

    Tapashree Roy

    2018-02-01

    Full Text Available In the recent years, metasurfaces, being flat and lightweight, have been designed to replace bulky optical components with various functions. We demonstrate a monolithic Micro-Electro-Mechanical System (MEMS integrated with a metasurface-based flat lens that focuses light in the mid-infrared spectrum. A two-dimensional scanning MEMS platform controls the angle of the lens along two orthogonal axes by ±9°, thus enabling dynamic beam steering. The device could be used to compensate for off-axis incident light and thus correct for aberrations such as coma. We show that for low angular displacements, the integrated lens-on-MEMS system does not affect the mechanical performance of the MEMS actuators and preserves the focused beam profile as well as the measured full width at half maximum. We envision a new class of flat optical devices with active control provided by the combination of metasurfaces and MEMS for a wide range of applications, such as miniaturized MEMS-based microscope systems, LIDAR scanners, and projection systems.

  5. Dynamic metasurface lens based on MEMS technology

    Science.gov (United States)

    Roy, Tapashree; Zhang, Shuyan; Jung, Il Woong; Troccoli, Mariano; Capasso, Federico; Lopez, Daniel

    2018-02-01

    In the recent years, metasurfaces, being flat and lightweight, have been designed to replace bulky optical components with various functions. We demonstrate a monolithic Micro-Electro-Mechanical System (MEMS) integrated with a metasurface-based flat lens that focuses light in the mid-infrared spectrum. A two-dimensional scanning MEMS platform controls the angle of the lens along two orthogonal axes by ±9°, thus enabling dynamic beam steering. The device could be used to compensate for off-axis incident light and thus correct for aberrations such as coma. We show that for low angular displacements, the integrated lens-on-MEMS system does not affect the mechanical performance of the MEMS actuators and preserves the focused beam profile as well as the measured full width at half maximum. We envision a new class of flat optical devices with active control provided by the combination of metasurfaces and MEMS for a wide range of applications, such as miniaturized MEMS-based microscope systems, LIDAR scanners, and projection systems.

  6. Gravitational Lens Time Delays Using Polarization Monitoring

    Directory of Open Access Journals (Sweden)

    Andrew Biggs

    2017-11-01

    Full Text Available Gravitational lens time delays provide a means of measuring the expansion of the Universe at high redshift (and therefore in the ‘Hubble flow’ that is independent of local calibrations. It was hoped that many of the radio lenses found in the JVAS/CLASS survey would yield time delays as these were selected to have flat spectra and are dominated by multiple compact components. However, despite extensive monitoring with the Very Large Array (VLA, time delays have only been measured for three of these systems (out of 22. We have begun a programme to reanalyse the existing VLA monitoring data with the goal of producing light curves in polarized flux and polarization position angle, either to improve delay measurements or to find delays for new sources. Here, we present preliminary results on the lens system B1600+434 which demonstrate the presence of correlated and substantial polarization variability in each image.

  7. Intraocular lens implantation in microphthalmic patients.

    Science.gov (United States)

    Sinskey, R M; Amin, P; Stoppel, J

    1992-09-01

    Microphthalmos is a developmental disorder of the eye consisting of a smaller than normal eye. This disorder can present as an isolated condition or associated with other systemic alterations. It is not uncommon for patients with microphthalmos to have congenital cataracts along with other ocular and systemic abnormalities. This paper reports the experience with 11 microphthalmic eyes of seven patients who had primary or secondary intraocular lens (IOL) implantation over a six-year period from 1985 to 1991. In all cases the IOL had a 13.5 mm or 14.0 mm overall diameter and a 6.0 mm or 6.5 mm optic. It was difficult to obtain documentation of objective visual improvement in many of these cases because of the associated nystagmus. However, all patients reported subjective improvements. These results suggest that with proper technique and lens selection microphthalmic patients should be considered for IOL implantation with relative safety and success.

  8. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  9. Strontium and cesium radionuclide leak detection alternatives in a capsule storage pool

    International Nuclear Information System (INIS)

    Larson, D.E.; Crawford, T.W.; Joyce, S.M.

    1981-08-01

    A study was performed to assess radionuclide leak-detection systems for use in locating a capsule leaking strontium-90 or cesium-137 into a water-filled pool. Each storage pool contains about 35,000 L of water and up to 715 capsules, each of which contains up to 150 kCi strontium-90 or 80 kCi cesium-137. Potential systems assessed included instrumental chemical analyses, radionuclide detection, visual examination, and other nondestructive nuclear-fuel examination techniques. Factors considered in the assessment include: cost, simplicity of maintenance and operation, technology availability, reliability, remote operation, sensitivity, and ability to locate an individual leaking capsule in its storage location. The study concluded that an adaption of the spent nuclear-fuel examination technique of wet sipping be considered for adaption. In the suggested approoch, samples would be taken continuously from pool water adjacent to the capsule(s) being examined for remote radiation detection. In-place capsule isolation and subsequent water sampling would confirm that a capsule was leaking radionuclides. Additional studies are needed before implementing this option. Two other techniques that show promise are ultrasonic testing and eddy-current testing

  10. Lens dislocation has a possible relationship with laser iridotomy

    OpenAIRE

    Mutoh, Tetsuya; Barrette, Kevin F; Matsumoto, Yukihiro; Chikuda, Makoto

    2012-01-01

    Tetsuya Mutoh,1,2 Kevin F Barrette,2 Yukihiro Matsumoto,1 Makoto Chikuda11Department of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Koshigaya City, Saitama, Japan; 2Department of Ophthalmology, Boston University School of Medicine, Boston, MA, USAAbstract: We report our recent experience of four eyes with spontaneous lens dislocation in four patients with no history of trauma or any systemic disease associated with zonular dialysis. Lens dislocation developed with 0.5 to 6 mo...

  11. The correct lens mount lightweighting design of thermal cycle stress in Cassegrain telescope

    Science.gov (United States)

    Hsu, M. Y.; Chang, S. T.; Huang, T. M.; Hsu, Ming-Ying

    2011-10-01

    The Cassegrain telescope system was design for space environment. The correct lens mount assembly is included as correct lens, lens mount, spacer, mount barrel and retainer. The system mass budget allocated to correct lens assembly was 5 Kg. Meanwhile, according to optical design the correct lens is made from fused silica, the lens diameter is 130 mm, and the mass is 2.3 Kg. Therefore, remain mass budget is 2.7 Kg; including the lens mount, spacer, mount barrel and retainer. The telescope system deformation is mainly caused by thermal deformation on space orbit. The correct lens mount was made from invar material in initial design. The CTE (Coefficient of Thermal Expansion) of invar is only 1* 10-6/°C, low CTE would be resistant to thermal deformation, but invar density is 8* 10-6 kg/mm3. If all components were made from invar, the total mass was over 2.7 kg. Thus, the components material would consider titanium alloy (CTE is 8.6* 10-6/°C, density is 4.43* 10-6 kg/mm3) or aluminum alloy (CTE is 23.6* 10-6/°C, density is 2.81* 10-6 kg/mm3). The titanium alloy density is 1.83 times lighter than invar, but CTE is 8.6 times higher. The aluminum alloy density is 2.84 times lighter then invar, but CTE is 23.6 times higher. The lens mount thermal deformation would effect correct lens surface wavefront error and introduce optical aberration. This article analyzes the correct lens assembly thermal deformation and optical performance in different lens mount material. From above conditions, using FEM (Finite Element Method) and optical software, simulation and optimization on the lens mount design have been performed to achieve system mass requirement.

  12. Chitah: Strong-gravitational-lens hunter in imaging surveys

    Energy Technology Data Exchange (ETDEWEB)

    Chan, James H. H.; Suyu, Sherry H.; Chiueh, Tzihong; More, Anupreeta; Marshall, Philip J.; Coupon, Jean; Oguri, Masamune; Price, Paul

    2015-07-07

    Strong gravitationally lensed quasars provide powerful means to study galaxy evolution and cosmology. Current and upcoming imaging surveys will contain thousands of new lensed quasars, augmenting the existing sample by at least two orders of magnitude. To find such lens systems, we built a robot, Chitah, that hunts for lensed quasars by modeling the configuration of the multiple quasar images. Specifically, given an image of an object that might be a lensed quasar, Chitah first disentangles the light from the supposed lens galaxy and the light from the multiple quasar images based on color information. A simple rule is designed to categorize the given object as a potential four-image (quad) or two-image (double) lensed quasar system. The configuration of the identified quasar images is subsequently modeled to classify whether the object is a lensed quasar system. We test the performance of Chitah using simulated lens systems based on the Canada–France–Hawaii Telescope Legacy Survey. For bright quads with large image separations (with Einstein radius ${r}_{\\mathrm{ein}}\\gt 1\\buildrel{\\prime\\prime}\\over{.} 1$) simulated using Gaussian point-spread functions, a high true-positive rate (TPR) of $\\sim 90\\%$ and a low false-positive rate of $\\sim 3\\%$ show that this is a promising approach to search for new lens systems. We obtain high TPR for lens systems with ${r}_{\\mathrm{ein}}\\gtrsim 0\\buildrel{\\prime\\prime}\\over{.} 5$, so the performance of Chitah is set by the seeing. We further feed a known gravitational lens system, COSMOS 5921+0638, to Chitah, and demonstrate that Chitah is able to classify this real gravitational lens system successfully. Our newly built Chitah is omnivorous and can hunt in any ground-based imaging surveys.

  13. Development of high precision and cryogenic lens holders

    Science.gov (United States)

    Reutlinger, A.; Boesz, Anton; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2017-11-01

    The optical system of the Near Infrared Spectrometer and Photometer (NISP) of the EUCLID mission consists mainly of a filter and grism wheel and 4 aspherical lenses with large diameters up to 170 mm. The single lenses require a high precision positioning at the operational temperature of 150 K. An additional design driver represents the CaF2 material of a lens, which is very sensitive wrt brittleness. The technical maturity of the combination of single features such as CaF2, large diameter (and mass), high precision and cryogenic conditions is considered as low. Therefore, a dedicated pre-development program has been launched to design and develop a first prototype of lens holder and to demonstrate the functional performance at representative operational conditions. The 4 lenses are divided into 3x lenses for the Camera Lens Assembly (CaLA) and 1x lens for the Corrector Lens Assembly (CoLA). Each lens is glue mounted onto solid state springs, part of an adaption ring. The adaption ring shall provide protection against vibration loads, high accuracy positioning, as well as quasi load free mounting of the lens under operational conditions. To reduce thermomechanical loads on the lens, the CTE of the adaption ring is adapted to that of the lens. The glue between lens and solid state spring has to withstand high tension loads during vibration. At the operational temperature the deviating CTE between glue and lens/adaption ring introduces shear loads into the glue interface, which are critical, in particular for the fragile CaF2 lens material. For the case of NISP the shear loads are controlled with the glue pad diameter and the glue thickness. In the context of the development activity many technology aspects such as various solid state spring designs, glue selection and glue handling have been investigated. A parametric structural model was developed to derive the specific design feature of each ring, such as spring force, number of springs, eigenfrequency, etc. This

  14. Contact Lens Wear at Altitude: Subcontact Lens Bubble Formation

    Science.gov (United States)

    1987-11-01

    incidence of (PMMA) lenses . Reported here are the results of contact lens subcontact lens bubble formation under scleral lenses at bubble studies with soft...vision from formation of large bubbles greater than 6,096 m (20,000 It). With soft contact lenses , bubble under their contact lenses . They also found...always located at the limbus and were without sequela to vision or corneal epithelial integrity. scleral lenses used by Jaeckle were permeable to gases

  15. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  16. Strontium-90 and cesium-137 in total diet

    International Nuclear Information System (INIS)

    1977-01-01

    Under the commission of Science and Technology Agency, Japan Chemical Analysis Center has analysed total diet samples collected from 30 prefectures (2 times per year), and determined to content of strontium-90 and cesium-137 in these samples. Each Prefectural public health laboratories and institutes have collected all the daily regular diet consumed for five persons, namely three meals and other eating between meals, for radiochemical analysis in polyethylene containers. These samples were collected to Japan Chemical Analysis Center after carbonization without smoke rising in the large stainless dish. At Japan Chemical Analysis Center, these samples were asked in an electric muffle furnance. And the ask to which both some carriers and hydrochloric acid were added, was destroyed under heating. The nuclides were dissolved into hydrochloric acid and filtrated, after it was added with nitric acid and heated to dryness. The filtrates was analysed for strontium-90 and cesium-137 using the method recommended by Science and Technology Agency. (author)

  17. Strontium-90 and cesium-137 in service water

    International Nuclear Information System (INIS)

    1979-01-01

    Prefectural public health laboratories and institutes and Japan Chemical Analysis Center have analysed the contents of strontium-90 and cesium-137 in service water under the commission of Science and Technology Agency. At each prefectural public health laboratories and institutes, 100 literes of service water (8 prefectures, water from the intake of each station of water works) and tap water (32 prefectures) were collected as sample twice a year. The samples were filtrated with large filter papers after addition and mixture of both some carries. The filtration was then applied on a column filled the sodium cation exchange resin, and all the cations were absorbed on it. These resin and filter papers were collected at Japan Chemical Analysis Center. At Japan Chemical Analysis Center, these collected samples were radiochemically analysed for strontium-90 and cesium-137 using the method applied for the analysis of rain and dry fallout materials. (author)

  18. Cesium-137, a drama recounted; Cesio-137, um drama recontado

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Suzane de Alencar

    2013-01-15

    The radiological accident with Cesium-137, which started on Goiania in 1987, did not stop with the end of radiological contamination and continues in a judicial, scientific and narrative process of identification and recognition of new victims. The drama occupies a central place on the dynamics of radiological event, as it extends its limits, inflects its intensity and updates the event. As a narrative of the event, the ethnography incorporates and brings up to date the drama as an analysis landmark and the description of the theme as it is absorbed by a dramatic process. Cesium-137, a drama recounted is a textual experimentation based on real events and characters picked out from statements reported in various narratives about the radiological accident. (author)

  19. A cesium-sputtering negative ion source for AMS investigations

    Science.gov (United States)

    Håkansson, K.; Hellborg, R.; Erlandsson, B.; Skog, G.; Stenström, K.; Wiebert, A.

    1996-02-01

    Accelerator mass spectrometry (AMS) requires ion sources delivering intense negative ion beams of high stability. At the Lund 3 MV Pelletron tandem accelerator a new Cs-sputtering source has therefore been constructed and installed. The source is equipped with a mechanism for automatically cracking the cesium galss ampoule inside the oven when the source is evacuated. The source is also equipped with a multiple sample holder which permits on-line sample changing without disrupting the operation of the electrostatic accelerator. In order to maximise the negative ion beam current the sample holder has a mechanism for moving the sample relative to the cesium beam. By doing this the lifetime of the samples can be increased.

  20. High temperature thermodynamic properties of the fission product compounds of cesium and rubidium

    International Nuclear Information System (INIS)

    Kohli, R.; Lacom, W.

    1986-01-01

    A variety of fission product chemical interactions occurs in the complex fuel/fission products/cladding system in a reactor fuel rod. Of these, the reactions of the chemically active, high yield, volatile fission products, cesium and rubidium, are of particular interest. To understand their chemistry, high temperature thermodynamic data are needed for various compounds of cesium and rubidium. An experimental research program has been initiated to obtain reliable thermodynamic data on various Cs and Rb compounds. To date, heat capacity measurements have been made on Cs and Rb chromates, molybdates, dichromate, dimolybdates and rubidium zirconate in the temperature range 300-800 K. In addition, measurements are currently in progress on Cs and Rb chalcogenides, halides, aluminates and silicates. The measured heat capacity data has been combined with published enthalpy and entropy values to obtain a complete set of thermodynamic functions for some of these compounds to 800 K. The data have been used to reanalyze the chemical state of irradiated UO 2 fuel and the chemistry of PCI failure of the cladding by halogen stress corrosion cracking of Zircaloy in Light Water Reactors (LWRs). (author)

  1. Water-soluble molecular capsule for the complexation of cesium and thallium cations.

    Science.gov (United States)

    Brotin, Thierry; Cavagnat, Dominique; Berthault, Patrick; Montserret, Roland; Buffeteau, Thierry

    2012-09-06

    Binding properties of cesium and thallium cations by an enantiopure cryptophane derivative PP-1 have been investigated in water under basic conditions. The binding process has been evidenced using electronic circular dichroism (ECD), and binding constants of the Cs(+)@PP-1 and Tl(+)@PP-1 complexes have been determined from isothermal titration calorimetry (ITC) experiments in LiOH/H(2)O, NaOH/H(2)O, and KOH/H(2)O solutions. In addition, Tl(+)@PP-1 complex has been characterized for the first time by (205)Tl NMR spectroscopy. Cryptophane 1 exhibits an exceptionally high affinity for thallium and cesium cations in a large range of experimental conditions (nature, concentration of the counterion, and temperature). For example, binding constants as high as 2.9 × 10(9) M(-1) and 5.3 × 10(8) M(-1) have been measured by ITC at 298 K in NaOH/H(2)O (0.1 M) solution, for the Tl(+)@PP-1 and Cs(+)@PP-1 complexes, respectively. The high affinity of cryptophane 1 for Cs(+) and Tl(+) cations is preserved at higher LiOH, NaOH, and KOH concentrations and under extreme basic conditions, revealing the stability and the great selectivity of this supramolecular system toward Li(+), Na(+), and K(+) cations.

  2. ScanSort{sup SM} at Whiteshell Laboratories for sorting of experimental cesium pond soil

    Energy Technology Data Exchange (ETDEWEB)

    Downey, H., E-mail: heath.downey@amecfw.com [Amec Foster Wheeler, Portland, ME (United States)

    2015-07-01

    The ScanSort{sup SM} soil sorting system is a unique and efficient radiological instrument used for measuring and sorting bulk soils and volumetric materials. The system performs automatic radioassay and segregation of preconditioned material using a gamma spectroscopy system mounted above a conveyor belt. It was deployed to the Whiteshell Laboratories site to process the excavated soils generated during the decommissioning of the former Experimental Cesium Pond. The ScanSort{sup SM} system was utilized to segregate material with Cs-137 concentrations above the established site unrestricted release and restricted site reuse levels as well as demonstrated the ability to accurately determine the radioactivity concentrations of the radiologically-impacted material and to confidently segregate volumes of that material for appropriate final disposition. (author)

  3. Extraction of cesium and strontium from nuclear waste

    Science.gov (United States)

    Davis, Jr., Milton W.; Bowers, Jr., Charles B.

    1988-01-01

    Cesium is extracted from acidified nuclear waste by contacting the waste with a bis 4,4'(5) [1-hydroxy-2-ethylhexyl]benzo 18-crown-6 compound and a cation exchanger in a matrix solution. Strontium is extracted from acidified nuclear waste by contacting the waste with a bis 4,4'(5') [1-hydroxyheptyl]cyclohexo 18-crown-6 compound, and a cation exchanger in a matrix solution.

  4. Percutaneous radiation therapy of peyronie's disease with 137cesium

    International Nuclear Information System (INIS)

    Schreiber, B.; Rossbach, T.; Schmitt, G.; Essen Univ.

    1978-01-01

    From 1966 to 1977, 49 patients suffering from Peyronie's disease received percutaneous radiation treatment with 137 Cesium ( 137 Cs). Therapy results were followed up for a period of from 2 months to 11 years. The method of 137 Cs radiation is described and the results compared with other forms of therapy. Percutaneous radiation therapy with 137 Cs seems to be the preferred treatment of Peyronie's disease because of its few side effects, rapid effectiveness, and low cost. (orig.) [de

  5. Cesium contamination of mosses in county Vas, Hungary

    International Nuclear Information System (INIS)

    Golya, I.; Sebestyen, R.

    1993-01-01

    Two species of mosses were examined to assess radiocesium contamination of Vas county, and to analyse some aspects of mosses for use as indicator of radioactive contamination. Experimental results demonstrated that the distribution of contamination in a given region could be characterized by the cesium contamination of mosses. Sampling sites should be selected with special attention paid to spots with high contamination. Regression analysis proved that the contamination of mosses originated from Chernobyl fallout. (author) 4 refs.; 2 figs

  6. Stretched Lens Array Photovoltaic Concentrator Technology Developed

    Science.gov (United States)

    Piszczor, Michael F., Jr.; O'Neill, Mark J.

    2004-01-01

    Solar arrays have been and continue to be the mainstay in providing power to nearly all commercial and government spacecraft. Light from the Sun is directly converted into electrical energy using solar cells. One way to reduce the cost of future space power systems is by minimizing the size and number of expensive solar cells by focusing the sunlight onto smaller cells using concentrator optics. The stretched lens array (SLA) is a unique concept that uses arched Fresnel lens concentrators to focus sunlight onto a line of high-efficiency solar cells located directly beneath. The SLA concept is based on the Solar Concentrator Array with Refractive Linear Element Technology (SCARLET) design that was used on NASA's New Millennium Deep Space 1 mission. The highly successful asteroid/comet rendezvous mission (1998 to 2001) demonstrated the performance and long-term durability of the SCARLET/SLA solar array design and set the foundation for further improvements to optimize its performance.

  7. Pulser for the Tevatron electron lens gun

    Energy Technology Data Exchange (ETDEWEB)

    Iouri Terechkine et al.

    2004-05-18

    To compensate for beam-beam interaction in Tevatron, an ''electron lens'' is considered to be an effective instrument. When a bunch of electrons with energy in the range (10-16) kV is overlapping with a bunch of antiprotons, the resulting focusing force for antiprotons can be adjusted by changing the electron beam current and by profiling its radial distribution. There exist several scenarios of how the system must function. According to one of them, an electron gun that supplies electrons must be fed by voltage pulses that follow with the frequency of antiproton bunches circulating in the Tevatron, which is about 2.5 MHz. To provide focusing tailored for each individual antiproton bunch, a modulator of the gun (pulser) must allow pulse-to-pulse voltage change. This report will cover main approaches to a design of a pulser for use with the gun of the Tevatron Electron Lens.

  8. Test procedures and instructions for Hanford complexant concentrate supernatant cesium removal using CST

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickson, D.W.

    1997-01-08

    This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test, using Hanford Complexant Concentrate supernatant liquor from tank 241-AN-107, in a bench-scale column. The cesium sorbent to be tested is crystalline silicotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-023, Hanford Complexant Concentrate Supernatant Cesium Removal Test Plan.

  9. Test procedures and instructions for Hanford tank waste supernatant cesium removal

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickson, D.W., Westinghouse Hanford

    1996-05-31

    This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test using Hanford Double-Shell Slurry Feed supernatant liquor from tank 251-AW-101 in a bench-scale column.Cesium sorbents to be tested include resorcinol-formaldehyde resin and crystalline silicotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-022, Hanford Tank Waste Supernatant Cesium Removal Test Plan.

  10. Separation of radio cesium from PUREX feed solution by sorption on composite ammonium molybdo phosphate (AMP)

    International Nuclear Information System (INIS)

    Singh, I.J.; Achuthan, P.V.; Jain, S.; Janardanan, C.; Gopalakrishnan, V.; Wattal, P.K.; Ramanujam, A.

    2001-01-01

    Composite AMP exchanger was developed and evaluated for separation of radio cesium from dissolver solutions of PUREX process using a column experiment. The composite shows excellent sorption of radio cesium from dissolver solutions without any loss of plutonium and uranium. The removal of radio cesium from dissolver solutions will help in lowering the degradation of tri-n-butyl phosphate (TBP) in the solvent extraction process and will also help in reducing the radiation related problems. (author)

  11. The pupil can control an artificial lens intuitively.

    Science.gov (United States)

    Fliedner, Jan; Heine, Christian; Bretthauer, Georg; Wilhelm, Helmut

    2014-02-04

    After cataract surgery, the ability to accommodate is lost. For this reason, a mechatronic IOL is being developed at the moment: The Artificial Accommodation System. This device requires an easily measureable indicator of the distance of the observed object to determine the demand of accommodation. As the pupil constricts with near vision, pupil size might be such an indicator. Our research focused on whether the pupil can control an artificial lens. A study with 14 healthy subjects aged between 24 and 64 years was conducted. An artificial lens with variable refractive power was mounted in front of one eye. In this eye, natural accommodation was greatly reduced or absent due to presbyopia, pseudophakia, or iatrogenic cycloplegia. The lens' refractive power was changed in a computer-controlled manner depending on changes in the pupil diameter of the second eye, which could not see the fixation stimulus. The subject's task was to get a clear focused image of the target in different distances. The lens can be controlled by the pupil intuitively (P < 1.8 × 10(-18)). Without prior knowledge, 11/14 subjects passed the first trial, and 31/41 trials were successful. Only one subject was not able to control the lens at all. Most subjects comprehended instantly how to use the unfamiliar lens control to bring a target into focus. This study emphasizes the plasticity of the visual control system. Positioning accuracy was acceptable, but the control must be optimized to facilitate maintaining a defined refractive power.

  12. Adaptive Liquid Lens Actuated by Droplet Movement

    Directory of Open Access Journals (Sweden)

    Chao Liu

    2014-08-01

    Full Text Available In this paper we report an adaptive liquid lens actuated by droplet movement. Four rectangular PMMA (Polymethyl Methacrylate substrates are stacked to form the device structure. Two ITO (Indium Tin Oxide sheets stick on the bottom substrate. One PMMA sheet with a light hole is inserted in the middle of the device. A conductive droplet is placed on the substrate and touches the PMMA sheet to form a small closed reservoir. The reservoir is filled with another immiscible non-conductive liquid. The non-conductive liquid can form a smooth concave interface with the light hole. When the device is applied with voltage, the droplet stretches towards the reservoir. The volume of the reservoir reduces, changing the curvature of the interface. The device can thus achieve the function of an adaptive lens. Our experiments show that the focal length can be varied from −10 to −159 mm as the applied voltage changes from 0 to 65 V. The response time of the liquid lens is ~75 ms. The proposed device has potential applications in many fields such as information displays, imaging systems, and laser scanning systems.

  13. Metabolism of {sup 137}cesium, {sup 137}barium in the rat. Therapeutics of the contamination; Metabolisme du {sup 137}cesium, {sup 137}baryum chez le rat. Therapeutique de la contamination

    Energy Technology Data Exchange (ETDEWEB)

    Remy, J.; Philippon, A.; Lafuma, J.; Walter, C. [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires. Departement de la Protection Sanitaire, Laboratoire de Radiopathologie

    1967-07-01

    The authors carry out research into the distribution kinetics, the metabolism and the excretion of {sup 137}Cs - {sup 137}Ba in the rat. They show that these phenomena are independent of the method of applying a single dose. The distribution tends to adopt in all cases a typical shape which remains the same depending on the body burden. Biological analysis of the state of the cesium in the biological media shows that it is transported in the free and ionised form. Considering the problem of the method of penetration of the cesium ion in the intracellular medium, and in particular by the in vivo and in vitro kinetic study of the plasma - red cell system, the authors make the assumption that an active transport of cesium occurs by the cell membrane. They thus arrive at an overall picture of the cesium distribution in the organism which is essentially characterized by a dynamic distribution equilibrium between two compartments: 99 per cent of the cesium accumulates in the intracellular pool, 1 per cent in the extracellular liquids. This latter compartment is open to the emunctories. Because, of the active transport by the cell membranes, the intracellular pool is filled rapidly but discharge is slow. This phenomenon is the limiting factor in the decrease of the body burden. From this representation, the authors deduce the reasons for the relative failure of the various therapeutic methods examined up till now by themselves or by other authors. The stimulation of the natural emunctories in the case of diuretics for example, can only improve the purification of the extracellular compartment. Now this latter contains only 1 per cent of the body burden and recharging is slow. Furthermore the methods designed to counteract or inhibit the active transport of cesium by the cell membrane are still at the present time incompatible with the survival of the cell. (authors) [French] Les auteurs etudient experimentalement la cinetique de distribution, le metabolisme et l

  14. Transition of cesium in food chains [after Chernobyl catastrophe

    International Nuclear Information System (INIS)

    Procházka, H.; Brunclík, T.; Jandl, J.; Jirásek, V.; Novosad, J.; Hampl, J.

    1990-01-01

    An investigation of 25,000 samples of foodstuffs and feedstuffs in Czechoslovakia, contaminated by fall-out cesium after the accident in the Chernobyl nuclear power plant, performed from May 5, 1986 to March 31, 1988, revealed that both the values of cesium transfer-factors in food--animal tissues--milk transitions and the values of biological half-life of cesium are functions of internal and external conditions of contamination. Organism individuality as the main internal condition causes the variance of about +/- 50% of the mean value of the respective transfer-factor. Through the external conditions, mainly the environmental contamination level, type of ingested food and time of ingestion, the mean values of transfer-factors are influenced up to 500%, e.g. to the value of 0.5. But this value converges with growing up contamination of food and environment to the limit of 0.3. The first two to three biological half-lives after the last ingestion of contaminated food are up to ten-times shorter than those at stabilized state

  15. Mineral-deposit model for lithium-cesium-tantalum pegmatites

    Science.gov (United States)

    Bradley, Dwight C.; McCauley, Andrew D.; Stillings, Lisa L.

    2017-06-20

    Lithium-cesium-tantalum (LCT) pegmatites comprise a compositionally defined subset of granitic pegmatites. The major minerals are quartz, potassium feldspar, albite, and muscovite; typical accessory minerals include biotite, garnet, tourmaline, and apatite. The principal lithium ore minerals are spodumene, petalite, and lepidolite; cesium mostly comes from pollucite; and tantalum mostly comes from columbite-tantalite. Tin ore as cassiterite and beryllium ore as beryl also occur in LCT pegmatites, as do a number of gemstones and high-value museum specimens of rare minerals. Individual crystals in LCT pegmatites can be enormous: the largest spodumene was 14 meters long, the largest beryl was 18 meters long, and the largest potassium feldspar was 49 meters long.Lithium-cesium-tantalum pegmatites account for about one-fourth of the world’s lithium production, most of the tantalum production, and all of the cesium production. Giant deposits include Tanco in Canada, Greenbushes in Australia, and Bikita in Zimbabwe. The largest lithium pegmatite in the United States, at King’s Mountain, North Carolina, is no longer being mined although large reserves of lithium remain. Depending on size and attitude of the pegmatite, a variety of mining techniques are used, including artisanal surface mining, open-pit surface mining, small underground workings, and large underground operations using room-and-pillar design. In favorable circumstances, what would otherwise be gangue minerals (quartz, potassium feldspar, albite, and muscovite) can be mined along with lithium and (or) tantalum as coproducts.Most LCT pegmatites are hosted in metamorphosed supracrustal rocks in the upper greenschist to lower amphibolite facies. Lithium-cesium-tantalum pegmatite intrusions generally are emplaced late during orogeny, with emplacement being controlled by pre-existing structures. Typically, they crop out near evolved, peraluminous granites and leucogranites from which they are inferred to be

  16. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  17. Cesium Toxicity Alters MicroRNA Processing and AGO1 Expressions in Arabidopsis thaliana.

    Directory of Open Access Journals (Sweden)

    Il Lae Jung

    Full Text Available MicroRNAs (miRNAs are short RNA fragments that play important roles in controlled gene silencing, thus regulating many biological processes in plants. Recent studies have indicated that plants modulate miRNAs to sustain their survival in response to a variety of environmental stimuli, such as biotic stresses, cold, drought, nutritional starvation, and toxic heavy metals. Cesium and radio-cesium contaminations have arisen as serious problems that both impede plant growth and enter the food chain through contaminated plants. Many studies have been performed to define plant responses against cesium intoxication. However, the complete profile of miRNAs in plants during cesium intoxication has not been established. Here we show the differential expression of the miRNAs that are mostly down-regulated during cesium intoxication. Furthermore, we found that cesium toxicity disrupts both the processing of pri-miRNAs and AGONOUTE 1 (AGO1-mediated gene silencing. AGO 1 seems to be especially destabilized by cesium toxicity, possibly through a proteolytic regulatory pathway. Our study presents a comprehensive profile of cesium-responsive miRNAs, which is distinct from that of potassium, and suggests two possible mechanisms underlying the cesium toxicity on miRNA metabolism.

  18. Removal of radioactive cesium from soil by ammonium citrate solution and ionic liquid

    International Nuclear Information System (INIS)

    Ishiwata, Shunji; Kitakouji, Manabu; Taga, Atsushi; Ogata, Fumihiko; Ouchi, Hidekazu; Yamanishi, Hirokuni; Inagaki, Masayo

    2015-01-01

    Radioactive cesium has strongly bound soil as time proceeded, which could not be cleaved in mild condition. We have found that serial treatment of ammonium citrate solution and ionic liquid removed radioactive cesium from soil effectively. The sequence of the treatment is crucial, since inverse serial treatment or mixture of two kinds of solution did not show such an effect, which suggested that ammonium citrate unlocked trapped cesium in soil and ionic liquid solved it. We also found that repeating serial treatment and prolonged treatment time additively removed cesium from soil. (author)

  19. Structure of cesium loaded iron phosphate glasses: An infrared and Raman spectroscopy study

    International Nuclear Information System (INIS)

    Joseph, Kitheri; Premila, M.; Amarendra, G.; Govindan Kutty, K.V.; Sundar, C.S.; Vasudeva Rao, P.R.

    2012-01-01

    The structure of cesium loaded iron phosphate glasses (IPG) was investigated using infrared and Raman spectroscopy. The spectra of the cesium doped samples revealed a structural modification of the parent glass owing to the incorporation of cesium. The structural changes could be correlated with the variation observed in the glass transition temperature of these glasses. Increased Cs-mediated cationic cross linking appears to be the reason for the initial rise in glass transition temperature up to 21 mol% Cs 2 O in IPG; while, breakdown of the phosphate network with increasing cesium content, brings down the glass transition temperature.

  20. Desorption of radioactive cesium by seawater from the suspended particles in river water.

    Science.gov (United States)

    Onodera, Masaki; Kirishima, Akira; Nagao, Seiya; Takamiya, Kouichi; Ohtsuki, Tsutomu; Akiyama, Daisuke; Sato, Nobuaki

    2017-10-01

    In 2011, the accident at the Fukushima-Daiichi nuclear power plant dispersed radioactive cesium throughout the environment, contaminating the land, rivers, and sea. Suspended particles containing clay minerals are the transportation medium for radioactive cesium from rivers to the ocean because cesium is strongly adsorbed between the layers of clay minerals, forming inner sphere complexes. In this study, the adsorption and desorption behaviors of radioactive cesium from suspended clay particles in river water have been investigated. The radioactive cesium adsorption and desorption experiments were performed with two kinds of suspended particulate using a batch method with 137 Cs tracers. In the cesium adsorption treatment performed before the desorption experiments, simulated river water having a total cesium concentration ([ 133+137 Cs + ] total ) of 1.3 nM (10 -9  mol/L) was used. The desorption experiments were mainly conducted at a solid-to-liquid ratio of 0.17 g/L. The desorption agents were natural seawater collected at 10 km north of the Fukushima-Daiichi nuclear power plant, artificial seawater, solutions of NaCl, KCl, NH 4 Cl, and 133 CsCl, and ultrapure water. The desorption behavior, which depends on the preloaded cesium concentration in the suspended particles, was also investigated. Based on the cesium desorption experiments using suspended particles, which contained about 1000 ng/g loaded cesium, the order of cesium desorption ratios for each desorption agent was determined as 1 M NaCl (80%) > 470 mM NaCl (65%) > 1 M KCl (30%) ≈ seawater (natural seawater and Daigo artificial seawater) > 1 M NH 4 Cl (20%) > 1 M 133 CsCl (15%) ≫ ultrapure water (2%). Moreover, an interesting result was obtained: The desorption ratio in the 470 mM NaCl solution was much higher than that in seawater, even though the Na + concentrations were identical. These results indicate that the cesium desorption mechanism is not a simple ion exchange reaction

  1. Gabor lens theory

    International Nuclear Information System (INIS)

    Irani, A.A.

    1978-01-01

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  2. Radioactive cesium. Dynamics and transport in forestal food-webs; Radioaktivt cesium. Dynamik och transport i skogliga naeringsvaevar

    Energy Technology Data Exchange (ETDEWEB)

    Palo, T.; Nelin, P. [Swedish Univ. of Agricultural Sciences, Umeaa (Sweden). Dept. of Animal Ecology; Bergman, R.; Nylen, T. [FOA NBC Defence, Umeaa (Sweden)

    1995-12-01

    This report summarises results from a radioecological study during 1994-1995 concerning turnover, redistribution and loss of radioactive Cesium (134 and 137) in boreal forest ecosystems, as well as uptake and transfer in important food-chains over moose, vole and vegetation. The basis for this report are 9 publications published 1994-95. These reports are presented in summary form. 9 refs, 17 figs.

  3. Reduction of the divergence angle of an incident beam to enhance the demagnification factor of a two-stage acceleration lens in a gas ion nanobeam system of several tens of keV

    Science.gov (United States)

    Ishii, Yasuyuki; Kojima, Takuji

    2018-04-01

    The demagnification factor of a two-stage acceleration lens in a gas ion nanobeam system that produces ion beams with energies in the order of 10 keV was enhanced in this study so that a hydrogen ion beam with a diameter of 115 nm could be produced. The reduction of the divergence angle of the incident beam into the two-stage acceleration lens is the effective method for enhancing the demagnification factor. The divergence angle has been gradually reduced by firstly introducing the preacceleration electrodes to control the divergence angle, namely divergence-angle-control electrodes, and secondly replacing an anode with a modified anode that possesses a Pierce electrode, both of which were in an ion source directly connected to the lens. In this study, the divergence angle of less than 3.6 × 10-4 rad that was previously used to produce a 160-nm hydrogen ion beam with the energy of 46 keV by the above procedure was numerically determined using an ion beam extraction simulation code. The determined minimum divergence angle of the incident ion beam was calculated to be 2.0 × 10-4 rad, which was about half of the previously obtained divergence angle; this was used to experimentally form a hydrogen beam with a diameter of 115 ± 10 nm and the energy of 47 keV. The demagnification factor was estimated to be 1,739 using the newly formed hydrogen beam, which was similar to the simulation result.

  4. Solid state cesium ion guns for surface studies

    International Nuclear Information System (INIS)

    Souzis, A.E.; Carr, W.E.; Kim, S.I.; Seidl, M.

    1990-01-01

    Three cesium ion guns covering the energy range of 5--5000 V are described. These guns use a novel source of cesium ions that combine the advantages of porous metal ionizers with those of aluminosilicate emitters. Cesium ions are chemically stored in a solid electrolyte pellet and are thermionically emitted from a porous thin film of tungsten at the surface. Cesium supply to the emitting surface is controlled by applying a bias across the pellet. A total charge of 10.0 C can be extracted, corresponding to greater than 2000 h of lifetime with an extraction current of 1.0 μA. This source is compact, stable, and easy to use, and produces a beam with >99.5% purity. It requires none of the differential pumping or associated hardware necessary in designs using cesium vapor and porous tungsten ionizers. It has been used in ultrahigh-vacuum (UHV) experiments at pressures of -10 Torr with no significant gas load. Three different types of extraction optics are used depending on the energy range desired. For low-energy deposition, a simple space-charge-limited planar diode with a perveance of 1x10 -7 A/V 3/2 is used. Current densities of 10.0 μA/cm 2 at the exit aperture for energies ≤20 V are typical. This type of source provides an alternative to vapor deposition with the advantage of precise flux calibration by integration of the ion current. For energies from 50 to 500 V and typical beam radii of 0.5 to 0.2 mm, a high perveance Pierce-type ion gun is used. This gun was designed with a perveance of 1x10 -9 A/V 3/2 and produces a beam with an effective temperature of 0.35 eV. For the energy range of 0.5 to 5 keV, the Pierce gun is used in conjunction with two Einzel lenses, enabling a large range of imaging ratios to be obtained. Beam radii of 60 to 300 μm are typical for beam currents of 50 nA to 1.0 μA

  5. Presbyopia and heat: changes associated with aging of the human lens suggest a functional role for the small heat shock protein, alpha-crystallin, in maintaining lens flexibility.

    Science.gov (United States)

    Heys, Karl R; Friedrich, Michael G; Truscott, Roger J W

    2007-12-01

    Presbyopia, the inability to focus up close, affects everyone by age 50 and is the most common eye condition. It is thought to result from changes to the lens over time making it less flexible. We present evidence that presbyopia may be the result of age-related changes to the proteins of the lens fibre cells. Specifically, we show that there is a progressive decrease in the concentration of the chaperone, alpha-crystallin, in human lens nuclei with age, as it becomes incorporated into high molecular weight aggregates and insoluble protein. This is accompanied by a large increase in lens stiffness. Stiffness increases even more dramatically after middle age following the disappearance of free soluble alpha-crystallin from the centre of the lens. These alterations in alpha-crystallin and aggregated protein in human lenses can be reproduced simply by exposing intact pig lenses to elevated temperatures, for example, 50 degrees C. In this model system, the same protein changes are also associated with a progressive increase in lens stiffness. These data suggest a functional role for alpha-crystallin in the human lens acting as a small heat shock protein and helping to maintain lens flexibility. Presbyopia may be the result of a loss of alpha-crystallin coupled with progressive heat-induced denaturation of structural proteins in the lens during the first five decades of life.

  6. Laboratory Demonstration of Axicon-Lens Coronagraph

    Science.gov (United States)

    Choi, Jaeho; Jea, Geonho

    2018-01-01

    The results of laboratory based experiments of the proposed coronagraph using axicon-lenses that is conjunction with a method of noninterferometric quantitative phase imaging for direct imaging of exoplanets is will present. The light source is passing through tiny holes drilled on the thin metal plate is used as the simulated stellar and its companions. Those diffracted light at the edge of the holes bears a similarity to the light from the bright stellar. Those images are evaginated about the optical axis after the maximum focal length of the first axicon lens. Then the evaginated images of have cut off using the motorized iris which means the suppressed the central stellar light preferentially. Various length between the holes which represent the angular distance are examined. The laboratory experimental results are shown that the axicon-lens coronagraph has feature of ability to achieve the smaller IWA than l/D and high-contrast direct imaging. The laboratory based axicon-lens coronagraph imaging support the symbolic computation results which has potential in direct imaging for finding exoplanet and various astrophysical activities. The setup of the coronagraph is simple to build and is durable to operate. Moreover it can be transported the planets images to a broadband spectrometric instrument that able to investigate the constituent of the planetary system.

  7. Cesium removal from the fuel storage water at the Savannah River Site R-Building Disassembly Basin using 3M Empore reg-sign-membrane filter technology

    International Nuclear Information System (INIS)

    Oji, L.N.; Thompson, M.C.; Peterson, K.; May, C.; Kafka, T.M.

    1998-01-01

    This report describes results from a seven-day demonstration of the use of 3M Empore membrane filter loaded with ion exchange material (potassium cobalt hexacynoferrate (CoHex)) for cesium uptake from the R-Disassembly Basin at the Savannah River Site. The goal of the demonstration was to evaluate the ability of the Process Absorber Development unit (PADU), a water pre-filtration /CoHex configuration on a skid, to remove cesium from R-Disassembly Basin at a linear processing flow rate of 22.7 liters per minute (1,195.8 liters/minute/m 2 or 29.35 gallons/minute/ft 2 ). Over 210,000 liters (> 55,500 gallons) of R-Disassembly Basin water was processed through the PADU without a cesium breakthrough, that is, the effluent after treatment with CoHex, contained less than detectable amounts of radioactive cesium. Some of the observed advantages of the Empore membrane filter technology over conventional packed column ion exchange systems includes rapid flow rates without channeling effects, low volume secondary waste and fast extraction or rapid kinetics per unit of flow

  8. Polarization response of RHIC electron lens lattices

    Directory of Open Access Journals (Sweden)

    V. H. Ranjbar

    2016-10-01

    Full Text Available Depolarization response for a system of two orthogonal snakes at irrational tunes is studied in depth using lattice independent spin integration. In particular we consider the effect of overlapping spin resonances in this system, to understand the impact of phase, tune, relative location and threshold strengths of the spin resonances. These results are benchmarked and compared to two dimensional direct tracking results for the RHIC e-lens lattice and the standard lattice. Finally we consider the effect of longitudinal motion via chromatic scans using direct six dimensional lattice tracking.

  9. Athermal design and analysis of glass-plastic hybrid lens

    Science.gov (United States)

    Yang, Jian; Cen, Zhaofeng; Li, Xiaotong

    2018-01-01

    With the rapid development of security market, the glass-plastic hybrid lens has gradually become a choice for the special requirements like high imaging quality in a wide temperature range and low cost. The reduction of spherical aberration is achieved by using aspherical surface instead of increasing the number of lenses. Obviously, plastic aspherical lens plays a great role in the cost reduction. However, the hybrid lens has a priority issue, which is the large thermal coefficient of expansion of plastic, causing focus shift and seriously affecting the imaging quality, so the hybrid lens is highly sensitive to the change of temperature. To ensure the system operates normally in a wide temperature range, it is necessary to eliminate the influence of temperature on the hybrid lens system. A practical design method named the Athermal Material Map is summarized and verified by an athermal design example according to the design index. It includes the distribution of optical power and selection of glass or plastic. The design result shows that the optical system has excellent imaging quality at a wide temperature range from -20 ° to 70 °. The method of athermal design in this paper has generality which could apply to optical system with plastic aspherical surface.

  10. Predicting scleral GP lens entrapped tear layer oxygen tensions.

    Science.gov (United States)

    Jaynes, Jared M; Edrington, Timothy B; Weissman, Barry A

    2015-02-01

    Over the past decade, utilization of scleral gas permeable (GP) contact lenses has steadily increased. Scleral GP lenses offer yet another option for patients suffering from visually debilitating corneal and tear conditions. Oxygen delivery to the cornea in the presence of a contact lens system continues to be a subject of interest, and scleral GP lenses are no exception. This paper utilizes an existing model based on simultaneous two lens systems (piggyback lenses) as a resistance to oxygen in series, and applies this model to scleral GP lens systems. Theoretical oxygen tensions are calculated for tear layers trapped beneath scleral contact lens systems and the anterior corneal surface with a simple single chamber corneal model using a computer software spreadsheet. Only the best case scenario for current scleral gas permeable lenses (thickness and Dk)/tear layer values allow sufficient tear layer oxygen tension (approximately 100 mmHg) to preclude corneal hypoxia. The results of the spreadsheet model suggest that clinicians would be prudent to prescribe scleral GP lenses manufactured in the highest Dk materials available and to fit without excessive corneal clearance to minimize anterior segment hypoxia. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  11. Cesium Carbonate-Catalyzed α-Phenylchalcogenation of Carbonyl Compounds with Diphenyl Dichalcogenide

    Directory of Open Access Journals (Sweden)

    Yutaka Nishiyama

    2009-09-01

    Full Text Available It was found that cesium carbonate has a unique catalytic ability on the reaction of carbonyl compounds with diphenyl diselenide to give the corresponding α-phenylseleno carbonyl compounds in moderate to good yields. Similarly, the α-phenylthiolation of carbonyl compounds with diphenyl disulfide was promoted by the cesium carbonate catalyst.

  12. Utilization of cesium-137 environmental contamination from fallout in erosion and sedimentation studies

    International Nuclear Information System (INIS)

    Guimaraes, M.F. da; Pessenda, L.C.R.; Fernandes, E.A.N.; Freire, O.; Nascimento Filho, V.F. do; Ferraz, E.S.B.

    1988-01-01

    The radioactivity of cesium-137 from fallout in different soils profiles for erosion and sedimentation studies are described. The potential of this technique for hydrographic basin in Piracicaba/Sao Paulo is evaluated. Due to the existence of natural radionuclides in soil, with energy near to cesium-137, the soil samples are determined by a high-purity Ge detectors. (author)

  13. Decorporation of mixture of strontium and cesium isotopes with domestic mineral waters

    International Nuclear Information System (INIS)

    Slavov, S.; Filev, G.; Kiradzhiev, G.

    1990-01-01

    The possibilities of Bulgarian mineral waters to decorporate mixtures of strontium and cesium radioisotopes, simultaneous entering the body, were studied. A modified effect in respect to radioactive strontium was found. Modification of the effect of mixing two diferent types of mineral waters was not proven. No effect was found of potassium-containing mineral water on radioactive cesium kinetics. 1 tab., 7 refs

  14. The effect of fertilizer application on 137 cesium accumulation in lucerne grown on a leached chernozem

    International Nuclear Information System (INIS)

    Konstantinov, G.; Kovachev, K.; Penchev, D.; Ermolaev, I.; Mirchev, M.

    1974-01-01

    On the basis of pot experiments, carried out in a glass-house the following conclusions on the effect of fertilizer application are made: nitrogen fertilizer application increases the amount of radioactive cesium in lucerne plants. Phosphorus fertilizer introduction, similarly to potassium fertilizer application decreases cesium uptake, resulting in an increase in available phosphorus in the soil. (M.Ts.)

  15. Cesium-137 uptake studies on ammonium phospho molybdate irradiated with electrons

    International Nuclear Information System (INIS)

    Rao, K.L.N.; Balasubramanian, K.R.; Shukla, J.P.

    1992-01-01

    Ammonium phospho molybdate is an important inorganic ion exchanger having high selectivity for cesium. This paper discusses the effects of electron irradiation to a dose of 1 mGy on this exchanger with special reference to its ion exchange performance using cesium-137 as a tracer. An explanation is attempted for the slight increase in the distribution coefficients. (author). 5 refs., 1 tab

  16. Determination of optical parameters of a GRIN lens by intercept measurement

    Science.gov (United States)

    Zhang, Yufei; Xiong, Baoxing; Xu, Qinfeng; Guo, Changwei; Zhang, Guiju; Xu, Feng; Zou, Kuaisheng

    2018-03-01

    An experimental method is used to measure the optical parameters of a GRIN lens. The intrinsic properties of the lens are well characterized by measuring the intercept values of the different GRIN lenses. Firstly, the intercept equation is derived from the transmission matrix of the GRIN lens, and the measurement method is described in detail. Secondly, we design and make the optical path measuring system. Finally, the error analysis of the experimental results is presented, which shows the feasibility of the working principle and the experiment operation. The principle and equipment of this measuring method are relatively effective, which affords great practical significance for the measurement of the GRIN lens.

  17. [Current quality management situation and administration countermeasure study of enterprises marketing corneal contact lens].

    Science.gov (United States)

    Liu, Yungui; Yao, Ying; Shangguan, Shihao; Gu, Qun; Gao, Wuming; Chen, Yaoshui

    2014-05-01

    Study the current quality management situation of enterprises marketing corneal contact lens via systemic investigations and explore effective administration countermeasures in the future. The quality management indicators of sixty-two corneal contact lens marketing enterprises in Xuhui district of Shanghai were systematically investigated and enterprises of different operation models was compared and analyzed. Wholesale enterprises and retail chain enterprises are apparently better than independent enterprises almost in all facets. Facilitate market accession of corneal contact lens marketing enterprises, encourage the business model of retail chain, enhance supervision of corneal contact lens marketing enterprises, especially independent franchisors.

  18. Study of the thermal diffusion of ion-alloyed cesium in aluminium, silicon and titanium by the Rutherford backscattering method

    International Nuclear Information System (INIS)

    Bulgakov, Yu.V.; Savel'eva, L.M.

    1987-01-01

    Thermal diffusion of cesium implanted at 120 keV energy in monocrystal silicon and in polycrystal aluminium and titanium is investigated by the method of Rutherford backscattering (RBS). Parameters of temperature dependence of the cesium diffusion coefficient in materials given above are determined. Cesium is shown to be one of the most movable impurities

  19. Hyperchromatic lens for recording time-resolved phenomena

    Science.gov (United States)

    Frayer, Daniel K.

    2017-07-11

    A method and apparatus for the capture of a high number of quasi-continuous effective frames of 2-D data from an event at very short time scales (from less than 10.sup.-12 to more than 10.sup.-8 seconds) is disclosed which allows for short recording windows and effective number of frames. Active illumination, from a chirped laser pulse directed to the event creates a reflection where wavelength is dependent upon time and spatial position is utilized to encode temporal phenomena onto wavelength. A hyperchromatic lens system receives the reflection and maps wavelength onto axial position. An image capture device, such as holography or plenoptic imaging device, captures the resultant focal stack from the hyperchromatic lens system in both spatial (imaging) and longitudinal (temporal) axes. The hyperchromatic lens system incorporates a combination of diffractive and refractive components to maximally separate focal position as a function of wavelength.

  20. Optical architecture of HoloLens mixed reality headset

    Science.gov (United States)

    Kress, Bernard C.; Cummings, William J.

    2017-06-01

    HoloLens by Microsoft Corp. is the world's first untethered Mixed Reality (MR) Head Mounted Display (HMD) system, released to developers in March 2016 as a Development Kit. We review in this paper the various display requirements and subsequent optical hardware choices we made for HoloLens. Its main achievements go along performance and comfort for the user: it is the first fully untethered MR headset, with the highest angular resolution and the industry's largest eyebox. It has the first inside-out global sensor fusion system including precise head tracking and 3D mapping all controlled by a fully custom on-board GPU. Based on such achievements, HoloLens came out as the most advanced MR system today. Additional features may be implemented in next generations MR headsets, leading to the ultimate experience for the user, and securing the upcoming fabulous AR/MR market predicted by most analysts.

  1. A framework of cloud supported collaborative design in glass lens moulds based on aspheric measurement

    Science.gov (United States)

    Zhu, Yongjian; Wang, Yu; Na, Jingxin; Zhi, Yanan; Fan, Yufeng

    2013-09-01

    Aspheric mould design includes the top-down design and reversal design. In this paper, a new framework of reversal design is proposed combining with cloud supported collaborative design (CSCD) based on aspheric measurement. The framework is a kind of collaborative platform, which is composed of eight modules, including the computerized aspheric precision measurement module (CAPM), computer-aided optical design of aspheric lens system (CAOD), computer-aided design of lens mould (CADLM), FEM(finite element method) simulation of lens molding module (FEMLM), computer-aided manufacture of lens and moulds (CAMLM), measurement data analysis module (MDAM), optical product lifecycle management module (OPLM) and cloud computing network module (CCNM). In this framework, the remote clients send an improved requirement or fabrication demand about optical lens system through CCNM, which transfers this signal to OPLM. In OPLM, one main server is in charge of the task distribution and collaborative work of other six modules. The first measurement data of aspheric lens are produced by clients or our proposed platform CAPM, then are sent to CAOD for optimization and the electronic drawings of lens moulds are generated in CADLM module. According the design drawings, the FEMLM could give the lens-molding simulation parameters through FEM software. The simulation data are used for the second design of moulds in CADLM module. In this case, the moulds could be fabricated in CAMLM by ultra-precision machine, and the aspheric lens could be also produced by lens-molding machine in CAMLM. At last, the final shape of aspheric lens could be measured in CAPM and the data analysis could be conducted in MDAM module. Through the proposed framework, all the work described above could be performed coordinately. And the optimum design data of lens mould could be realized and saved, then shared by all the work team.

  2. Cesium Eluate Evaporation Solubility and Physical Property Behavior

    International Nuclear Information System (INIS)

    Pierce, R.A.

    2003-01-01

    The baseline flowsheet for low activity waste (LAW) in the Hanford River Protection Project (RPP) Waste Treatment Plant (WTP) includes pretreatment of supernatant by removing cesium using ion exchange. When the ion exchange column is loaded, the cesium will be eluted with a 0.5M nitric acid (HNO3) solution to allow the column to be conditioned for re-use. The cesium eluate solution will then be concentrated in a vacuum evaporator to minimize storage volume and recycle HNO3. To prevent the formation of solids during storage of the evaporator bottoms, criteria have been set for limiting the concentration of the evaporator product to 80 percent of saturation at 25 degrees C. A fundamental element of predicting evaporator product solubility is to collect data that can be used to estimate key operating parameters. The data must be able to predict evaporator behavior for a range of eluate concentrations that are evaporated to the point of precipitation. Parameters that were selected for modeling include solubility, density, viscosity, thermal conductivity, and heat capacity. Of central importance is identifying the effect of varying feed components on overall solubility. The point of solubility defines the upper limit for eluate evaporation operations and liquid storage. The solubility point also defines those chemical compounds that have the greatest effects on physical properties. Third, solubility behavior identifies intermediate points where physical property data should be measured for the database. Physical property data (density, viscosity, thermal conductivity, and heat capacity) may be an integral part of tracking evaporator operations as they progress toward their end point. Once the data have been collected, statistical design software can develop mathematical equations that estimate solubility and other physical properties

  3. Cesium ion exchange using actual waste: Column size considerations

    International Nuclear Information System (INIS)

    Brooks, K.P.

    1996-04-01

    It is presently planned to remove cesium from Hanford tank waste supernates and sludge wash solutions using ion exchange. To support the development of a cesium ion exchange process, laboratory experiments produced column breakthrough curves using wastes simulants in 200 mL columns. To verify the validity of the simulant tests, column runs with actual supernatants are being planned. The purpose of these actual waste tests is two-fold. First, the tests will verify that use of the simulant accurately reflects the equilibrium and rate behavior of the resin compared to actual wastes. Batch tests and column tests will be used to compare equilibrium behaviors and rate behaviors, respectively. Second, the tests will assist in clarifying the negative interactions between the actual waste and the ion exchange resin, which cannot be effectively tested with simulant. Such interactions include organic fouling of the resin and salt precipitation in the column. These effects may affect the shape of the column breakthrough curve. The reduction in column size also may change the shape of the curve, making the individual effects even more difficult to sort out. To simplify the evaluation, the changes due to column size must be either understood or eliminated. This report describes the determination of the column size for actual waste testing that best minimizes the effect of scale-down. This evaluation will provide a theoretical basis for the dimensions of the column. Experimental testing is still required before the final decision can be made. This evaluation will be confined to the study of CS-100 and R-F resins with NCAW simulant and to a limited extent DSSF waste simulant. Only the cesium loading phase has been considered

  4. The Effect of a Simulated Macropore on the Colloid-Facilitated Transport of Cesium and Strontium: Experiment and Model Results

    Science.gov (United States)

    Dittrich, T. M.; Ryan, J. N.; Saiers, J. E.

    2011-12-01

    The sorption of contaminants to mobile colloids has been shown to increase the transport of the contaminants in a process known as colloid-facilitated transport. Many laboratory experiments and computer model simulations have shown that enhanced transport can occur when a contaminant strongly associates with mobile colloids and release kinetics are slow relative to the rate of flow. Knowing when colloid-facilitated transport will affect field-scale situations and risk assessment decisions has been difficult. The three parts of our research were (1) conduct a set of isotherms and breakthrough curves for a well-characterized system (illite colloids, homogeneous quartz sand, saturated and unsaturated conditions), (2) conduct breakthrough experiments with the addition of a central macropore and, (3) model the results to identify and quantify the effects of desorption kinetics and unsaturated conditions on colloid-facilitated transport with a macropore. Breakthrough experiments used a 12.7 cm diameter and 33.5 cm long column packed with cleaned and sieved quartz sand. The homogeneous experiments used sand with a median grain size of 0.325 mm. For macropore experiments, a 2 cm diameter tube of 1.6 mm sand (about 5× the size of the matrix sand) was packed in the center of the column. A rainfall simulator was suspended over the column and a relative saturation of 1.0, 0.80, or 0.33 was established. Three moisture sensors and three tensiometers monitored the flow conditions. Effluent was collected with a peristaltic pump and a fraction collector and measured for total and dissolved ions, pH, and colloid concentration. Cesium and strontium were used as model contaminants because they are common contaminants found on Department of Energy sites in the United States and because they have contrasting sorption kinetics with illite. A previously developed model for saturated colloid-facilitated transport of cesium and strontium was extended to accommodate unsaturated conditions

  5. Cesium fallout in Norway after the Chernobyl accident

    International Nuclear Information System (INIS)

    Backe, S.; Bjerke, H.; Rudjord, A.L.; Ugletveit, F.

    1986-01-01

    Results of country-wide measurements of 137 Cs and 134 Cs in soil samples in Norway after the Chernobyl accident are reported. The results clearly demonstrates that municipalities in the central part of southern Norway, Troendelag and the southern part of Nordland, have been rather heavily contaminated. The total fallout of 137 Cs and 134 Cs from the Chernobyl accident in Norway is estimated to 2300 TBq and 1200 TBq, respectively. This is approximately 6% of the cesium activity released from the reactor

  6. Effect of illite particle shape on cesium sorption

    Science.gov (United States)

    Rajec, Pavol; Šucha, Vladimír; Eberl, Dennis D.; Środoń, Jan; Elsass, Françoise E.

    1999-01-01

    Samples containing illite and illite-smectite, having different crystal shapes (plates, “barrels”, and filaments), were selected for sorption experiments with cesium. There is a positive correlation between total surface area and Cs-sorption capacity, but no correlation between total surface area and the distribution coefficient, Kd. Generally Kd increases with the edge surface area, although “hairy” (filamentous) illite does not fit this pattern, possibly because elongation of crystals along one axis reduces the number of specific sorption sites.

  7. Low-temperature phase transformation in rubidium and cesium superoxides

    International Nuclear Information System (INIS)

    Alikhanov, R.A.; Toshich, B.S.; Smirnov, L.S.

    1980-01-01

    Crystal structures of rubidium and cesium superoxides which are two interpenetrating lattices of metal ions and oxygen molecule ions reveal a number of phase transformations with temperature decrease. Crystal-phase transformations in CsO 2 are 1-2, 2-3 and low temperature one 3-4 at 378, 190 and 10 K. Low temperature transition is considered as the instability of lattice quadrupoles of oxygen molecule ions to phase transformation of the order-disorder type. Calculated temperatures of low temperature phase transformations in PbO 2 and CsO 2 agree with experimental calculations satisfactory [ru

  8. Ternary phosphates of rubidium-cesium-rare earth element

    International Nuclear Information System (INIS)

    Mel'nikov, P.P.; Carrillo-Eredero, H.D.; Efremov, V.A.; Komissarova, L.N.; Quiroga, E.

    1986-01-01

    This article examines the possibility of the existence of ternary phosphates of the rare earth elements (REE) containing two large alkali cations in order to establish the morphological and physicochemical characteristics in the entire group of ternary REE phosphates. The synthesis of the ternary rubidium-cesium-REE phosphates was carried out with molten charges that did not contain an excess of components. Analysis for the uncommon alkali cations was done by the atomic absorption technique; for holmium, by complexometric titration; and for phosphorus, by gravimetry as NH 4 CdPO 4 . The data obtained fully confirm the composition of Rb 2 CsLn(PO 4 ) 2

  9. Standard method of test for radioactive cesium in water

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Concentrations of radioactive Cs greater than 1 μCi/l in water were determined by gamma counting after separation by extraction. The method is limited to 134 Cs, 136 Cs, 137 Cs, and 138 Cs. The radioactive Cs is extracted at pH 7.0 as cesium tetraphenylborate in amyl acetate with EDTA present to prevent the extraction of undesirable fission products. The γ activity of a sample of the organic phase is determined by γ spectroscopy. Large amounts of Na + , K + , Cs + , Rb + , NH 4 + , Ag + , and free acid interfere with the separation process in the procedure. The overall precision of the method is +-5 percent

  10. Sorption of trace cesium on 21 Hanford Site sediment types

    International Nuclear Information System (INIS)

    Routson, R.C.; Barney, G.S.; Smith, R.M.; Delegard, C.A.

    1980-03-01

    Sorption of trace cesium (Cs) was measured on 21 Hanford Site sediment types. A Box-Behnken statistical design was used to develop empirical-statistical equations predicting 137 Cs sorption as a function of the equilibrium concentrations of macroions Na + , K + , and Ca +2 in solution over the concentration ranges of 3.0 to 0.001M, 0.2 to 0.002M, and 0.2 to 0.002M, respectively. These equations are required to estimate trace Cs transport from Hanford ground disposal sites. Average Cs sorption equations for the 21 sediments will be presented and discussed

  11. Dissecting the Gravitational lens B1608+656 : II. Precision Measurements of the Hubble Constant, Spatial Curvature, and the Dark Energy Equation of State

    NARCIS (Netherlands)

    Suyu, S. H.; Marshall, P. J.; Auger, M. W.; Hilbert, S.; Blandford, R. D.; Koopmans, L. V. E.; Fassnacht, C. D.; Treu, T.

    2010-01-01

    Strong gravitational lens systems with measured time delays between the multiple images provide a method for measuring the "time-delay distance" to the lens, and thus the Hubble constant. We present a Bayesian analysis of the strong gravitational lens system B1608+656, incorporating (1) new, deep

  12. Computer-aided lens assembly

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-01

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet.

  13. Cesium Isotherm Testing with Spherical Resorcinol-Formaldehyde Resin at High Sodium Concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smoot, Margaret R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rinehart, Donald E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-04-01

    Washington River Protection Solutions (WRPS) is developing a Low-Activity Waste Pretreatment System (LAWPS) to provide low-activity waste (LAW) directly to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste Facility for immobilization. The pretreatment that will be conducted on tank waste supernate at the LAWPS facility entails filtration to remove entrained solids and cesium (Cs) ion exchange to remove Cs from the product sent to the WTP. Currently, spherical resorcinol-formaldehyde (sRF) resin (Microbeads AS, Skedsmokorset, Norway) is the Cs ion exchange resin of choice. Most work on Cs ion exchange efficacy in Hanford tank waste has been conducted at nominally 5 M sodium (Na). WRPS is examining the possibility of processing supernatant at high Na concentrations—up to 8 M Na—to maximize processing efficiency through the LAWPS. Minimal Cs ion exchange work has been conducted at 6 M and 8 M Na concentrations..

  14. Electron electric dipole moment experiment using electric-fieldquantized slow cesium atoms

    Energy Technology Data Exchange (ETDEWEB)

    Amini, Jason M.; Munger Jr., Charles T.; Gould, Harvey.

    2007-04-05

    A proof-of-principle electron electric dipole moment (e-EDM)experiment using slow cesium atoms, nulled magnetic fields, and electricfield quantization has been performed. With the ambient magnetic fieldsseen by the atoms reduced to less than 200 pT, an electric field of 6MV/m lifts the degeneracy between states of unequal lbar mF rbar and,along with the low (approximately 3 m/s) velocity, suppresses thesystematic effect from the motional magnetic field. The low velocity andsmall residual magnetic field have made it possible to induce transitionsbetween states and to perform state preparation, analysis, and detectionin regions free of applied static magnetic and electric fields. Thisexperiment demonstrates techniques that may be used to improve the e-EDMlimit by two orders of magnitude, but it is not in itself a sensitivee-EDM search, mostly due to limitations of the laser system.

  15. Accumulation of cesium-137 by different species of plants in the zone of floods

    International Nuclear Information System (INIS)

    Matsko, V.P.; Gaponenko, V.I.; Sukhover, L.K.

    2000-01-01

    Study was carried out in some areas of Brest, Gomel and Mogilev regions suffering from periodical floods. Cesium-137 accumulation by plants of various species and families differing phylogenetically and with different root systems has been investigated. The specific activity of soil (SAS) for Cs137 varied within the range of 190...154700 Bq/kg and that of overground phytomass was within 20...28000 Bq/kg. The inverse relationship was found between SAS and the values of radionuclide accumulation factor (RAF) by plants, the correlation of SAP (Bq/kg) and SAS (Bq/kg) as well as great importance of morpho-physiological characteristics in this process. RAF in higly organized species (angiospermous) is lower than in phylogenetically older plants (lichens, mosses)

  16. Criteria for cesium capsules to be shipped as special form radioactive material

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this report is to compile all the documentation which defines the criteria for Waste Encapsulation and Storage Facility (WESF) cesium capsules at the IOTECH facility and Applied Radiant Energy Corporation (ARECO) to be shipped as special form radioactive material in the Beneficial Uses Shipping System (BUSS) Cask. The capsules were originally approved as special form in 1975, but in 1988 the integrity of the capsules came into question. WHC developed the Pre-shipment Acceptance Test Criteria for capsules to meet in order to be shipped as special form material. The Department of Energy approved the criteria and directed WHC to ship the capsules at IOTECH and ARECO meeting this criteria to WHC as special form material

  17. Acanthamoeba keratitis. Contact lens and noncontact lens characteristics.

    Science.gov (United States)

    Chynn, E W; Lopez, M A; Pavan-Langston, D; Talamo, J H

    1995-09-01

    To identify potential differences in time to diagnosis and final visual outcome between contact lens and noncontact lens users with Acanthamoeba keratitis. Prior studies have shown early diagnosis and therapy to be related to outcome but have not analyzed differences among patients with and without contact lenses. A retrospective analysis of 11 consecutive cases (involving 13 eyes) of Acanthamoeba keratitis diagnosed at one institution over a 3-year period. Mean time to diagnosis was significantly longer in noncontact lens users versus those who wore contact lenses (mean, 5.8 versus 3.3 weeks). Fifty percent of patients who did not wear contact lenses had a poor outcome (visual acuity worse than 20/40 or penetrating keratoplasty) versus 14% of patients who wore contact lenses. Diagnoses were made later in patients without contact lenses, and these patients had a worse visual outcome than those with Acanthamoeba keratitis who wore contact lenses. All patients with unresponsive microbial keratitis, even those without contact lens use, should be evaluated for Acanthamoeba.

  18. Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading

    Directory of Open Access Journals (Sweden)

    You Na Kim

    2016-01-01

    Full Text Available Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III lens grading and corrected distance visual acuity (BCVA. Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were analyzed using ImageJ software. The lens grade and nuclear density were represented in pixel intensity units (PIU and correlations between PIU, BCVA, and LOCS III were assessed. Results. Forty-seven eyes were analyzed. The mean whole lens and lens nuclear densities were 26.99 ± 5.23 and 19.43 ± 6.15 PIU, respectively. A positive linear correlation was observed between lens opacities (R2 = 0.187, p<0.01 and nuclear density (R2 = 0.316, p<0.01 obtained from OCT images and LOCS III. Preoperative BCVA and LOCS III were also positively correlated (R2 = 0.454, p<0.01. Conclusions. Whole lens and lens nuclear densities obtained from OCT correlated with LOCS III. Nuclear density showed a higher positive correlation with LOCS III than whole lens density. OCT with a liquid optics interface is a potential quantitative method for lens grading and can aid in monitoring and managing age-related cataracts.

  19. [Contact lens-associated Paecilomyces lilacinus keratitis].

    Science.gov (United States)

    Mihailovic, N; Alnawaiseh, M; Zumhagen, L; Eter, N

    2017-01-01

    We present the case of a 23-year-old otherwise healthy female patient with contact lens-associated Paecilomyces lilacinus keratitis. The clinical findings stabilized after initial local antimycotic and antibacterial treatment; however, in the further course of local therapy an extensive relapse occurred which required treatment by perforating keratoplasty à chaud due to a penetrating corneal ulcer. The patient responded well to subsequent treatment with systemic and local antimycotic medication. After a few months HLA-matched keratoplasty was performed. During the follow-up time of 14 months there were no signs of recurrence of the infection.

  20. An integral-field spectroscopic strong lens survey

    Energy Technology Data Exchange (ETDEWEB)

    Bolton, Adam S [Harvard-Smithsonian Center for Astrophysics, 60 Garden St. MS-20, Cambridge, MA 02138 (United States); Burles, Scott [Department of Physics and Kavli Institute, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA 02139 (United States)

    2007-12-15

    We present the observational results of a survey for strong gravitational lens systems consisting of extended emission-line galaxies lensed by intervening early-type galaxies, conducted using integral field units (IFUs) of the Magellan IMACS and Gemini GMOS-N spectrographs. These data are highly valuable for corroborating the lensing interpretation of Hubble Space Telescope imaging data. We show that in many cases, ground-based IFU spectroscopy is in fact competitive with space-based imaging for the measurement of the mass model parameters of the lensing galaxy. We demonstrate a novel technique of three-dimensional gravitational lens modeling for a single lens system with a resolved lensed rotation curve. We also describe the details of our custom IFU data analysis software, which performs optimal multi-fiber extraction, relative and absolute wavelength calibration to a few hundredths of a pixel RMS and nearly Poisson-limited sky subtraction.

  1. An integral-field spectroscopic strong lens survey

    International Nuclear Information System (INIS)

    Bolton, Adam S; Burles, Scott

    2007-01-01

    We present the observational results of a survey for strong gravitational lens systems consisting of extended emission-line galaxies lensed by intervening early-type galaxies, conducted using integral field units (IFUs) of the Magellan IMACS and Gemini GMOS-N spectrographs. These data are highly valuable for corroborating the lensing interpretation of Hubble Space Telescope imaging data. We show that in many cases, ground-based IFU spectroscopy is in fact competitive with space-based imaging for the measurement of the mass model parameters of the lensing galaxy. We demonstrate a novel technique of three-dimensional gravitational lens modeling for a single lens system with a resolved lensed rotation curve. We also describe the details of our custom IFU data analysis software, which performs optimal multi-fiber extraction, relative and absolute wavelength calibration to a few hundredths of a pixel RMS and nearly Poisson-limited sky subtraction

  2. Technical Approach for the Development of a Near Tank Cesium Removal Process

    International Nuclear Information System (INIS)

    Sams, T.L.; Miller, Ch.E.; Kurath, D.E.; Blanchard, D.L.

    2009-01-01

    Parsons has been selected for development of two Advanced Remediation Technology (ART) projects. One of these projects is the Near Tank Cesium Removal (NTCR) project. The NTCR system uses the same basic ion exchange approach for Cs removal that has been used for decades in the nuclear industry. The essential difference in this approach is the development of a modular, mobile design concept based on a simplified process employing an advanced resin media and the use of cool nitric acid for elution and heated nitric acid for resin digestion. Under these conditions, the NTCR process shows significant improvements over the baseline ion exchange technology. These improvements will allow DOE to deploy a NTCR, free up tank space and accelerate closure of SSTs prior to Waste Treatment Plant Pretreatment Facility startup (WTP PTF). Current estimates indicate that the Hanford tank farm system will run out of available storage space prior to startup of the WTP PTF currently scheduled for 2019. The lack of tank space will constrain the near-term goal of retrieving waste from single-shell tanks prior to full operation of the WTP. A deployment of an NTCR system will allow LAW processing to begin as soon as supplemental treatment (e.g. Bulk Vitrification) or the WTP LAW Vitrification Facility becomes available. The NTCR system is a self contained modular, transportable system that requires only limited process chemicals and separates the HLW into two process streams. Once the cesium is removed, the low activity waste stream can be vitrified. The high activity stream would be stored in the DST system until vitrified by the WTP High Level Waste (HLW) Facility. This technology can be sized to feed the WTP LAW melters at the nominal operating capacity (30 MT glass per day. Alternatively, it could be sized to feed a supplemental treatment system such the Bulk Vitrification process. The NTCR system is based on an elutable ion exchange system using the Spherical Resorcinol Formaldehyde

  3. 137Cesium and soil carbon in a small agricultural watershed

    International Nuclear Information System (INIS)

    Ritchie, J.C.; McCarty, G.W.

    2003-01-01

    Scientific, political, and social interests have developed recently in the concept of using agricultural soils to sequester carbon. Studies supporting this concept indicate that soil erosion and subsequent redeposition of eroded soils in the same field may establish an ecosystem disequilibrium that promotes the buildup of carbon on agricultural landscapes. The problem is to determine the patterns of soil erosion and redeposition on the landscape and to relate these to soil carbon patterns. Radioactive 137 cesium ( 137 Cs) can be used to estimate soil erosion patterns and, more importantly, redeposition patterns at the field level. The purpose of this study was to determine the relationship between 137 Cs, soil erosion, and soil carbon patterns on a small agricultural watershed. Profiles of soils from an upland area and soils in an adjacent riparian system were collected in 5 cm increments and the concentrations of 137 Cs and carbon were determined. 137 Cs and carbon were uniformly mixed in the upper 15-20 cm of upland soils. 137 Cs (Bq g -1 ) and carbon (%) in the upland soils were significantly correlated (r 2 =0.66). Carbon content of the 0-20 cm layer was higher (1.4±0.3%) in areas of soil deposition than carbon content (1.1±0.3%) in areas of soil erosion as determined by the 137 Cs technique. These data suggest that measurements of 137 Cs in the soils can be useful for understanding carbon distribution patterns in surface soil. Carbon content of the upland soils ranged from 0.5 to 1.9% with an average of 1.2±0.4% in the 0-20 cm layer while carbon below this upper tilled layer (20-30 cm) ranged from 0.2 to 1.5% with an average of 0.5±0.3%. Total carbon was 2.66 and 3.20 kg m -2 in the upper 20 cm and upper 30 cm of the upland soils, respectively. Carbon content of the 0-20 cm layer in the riparian system ranged from 1.1 to 67.0% with an average 11.7±17.1%. Carbon content below 20 cm ranged from 1.8 to 79.3% with an average of 18.3±17.5%. Soil carbon in the

  4. A microcapillary lens for X-rays

    CERN Document Server

    Dudchik, Y I

    1999-01-01

    A new design of a compound refractive lens for X-rays is proposed. The lens is made as a set of glue microlenses placed in a glass capillary. The technique of lens fabrication is described. Results of ray tracing calculations for 8 and 15 keV photons are represented.

  5. An Experimental Study of the Fluorescence Spectrum of Cesium Atoms in the Presence of a Buffer Gas

    Science.gov (United States)

    Davydov, V. G.; Kulyasov, V. N.

    2018-01-01

    A direct experiment is performed to determine the quantum efficiency of a cesium fluorescence filter. The fluorescence spectra of cesium atoms are recorded under excitation of the upper states of the second resonance doublet with a Bell-Bloom cesium lamp. Introduction of different noble gases into the cell with cesium leads to the appearance of additional fluorescence photons. It is found that a fluorescence filter based on atomic cesium vapor with addition of helium in the working cell has the highest efficiency and response rate of all known fluorescence filters based on alkali-metal atomic vapors.

  6. Kelvin probe studies of cesium telluride photocathode for AWA photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Wisniewski, Eric E., E-mail: ewisniew@anl.gov [High Energy Physics Division, Argonne National Laboratory, 9700 S. Cass, Lemont, IL 60439 (United States); Physics Department, Illinois Institute of Technology, 3300 South Federal Street, Chicago, IL 60616 (United States); Velazquez, Daniel [High Energy Physics Division, Argonne National Laboratory, 9700 S. Cass, Lemont, IL 60439 (United States); Physics Department, Illinois Institute of Technology, 3300 South Federal Street, Chicago, IL 60616 (United States); Yusof, Zikri, E-mail: zyusof@hawk.iit.edu [High Energy Physics Division, Argonne National Laboratory, 9700 S. Cass, Lemont, IL 60439 (United States); Physics Department, Illinois Institute of Technology, 3300 South Federal Street, Chicago, IL 60616 (United States); Spentzouris, Linda; Terry, Jeff [Physics Department, Illinois Institute of Technology, 3300 South Federal Street, Chicago, IL 60616 (United States); Sarkar, Tapash J. [Rice University, 6100 Main, Houston, TX 77005 (United States); Harkay, Katherine [Accelerator Science Division, Argonne National Laboratory, 9700 S. Cass, Lemont, IL 60439 (United States)

    2013-05-21

    Cesium telluride is an important photocathode as an electron source for particle accelerators. It has a relatively high quantum efficiency (>1%), is sufficiently robust in a photoinjector, and has a long lifetime. This photocathode is grown in-house for a new Argonne Wakefield Accelerator (AWA) beamline to produce high charge per bunch (≈50nC) in a long bunch train. Here, we present a study of the work function of cesium telluride photocathode using the Kelvin probe technique. The study includes an investigation of the correlation between the quantum efficiency and the work function, the effect of photocathode aging, the effect of UV exposure on the work function, and the evolution of the work function during and after photocathode rejuvenation via heating. -- Highlights: ► The correlation between Quantum Efficiency (QE) and work function. ► How QE and work function evolve together. ► Rejuvenation of the photocathode via heating and the effect on work function. ► The effects on the work function due to exposure to UV light.

  7. Lasing in robust cesium lead halide perovskite nanowires

    Science.gov (United States)

    Eaton, Samuel W.; Lai, Minliang; Gibson, Natalie A.; Wong, Andrew B.; Dou, Letian; Ma, Jie; Wang, Lin-Wang; Leone, Stephen R.; Yang, Peidong

    2016-01-01

    The rapidly growing field of nanoscale lasers can be advanced through the discovery of new, tunable light sources. The emission wavelength tunability demonstrated in perovskite materials is an attractive property for nanoscale lasers. Whereas organic–inorganic lead halide perovskite materials are known for their instability, cesium lead halides offer a robust alternative without sacrificing emission tunability or ease of synthesis. Here, we report the low-temperature, solution-phase growth of cesium lead halide nanowires exhibiting low-threshold lasing and high stability. The as-grown nanowires are single crystalline with well-formed facets, and act as high-quality laser cavities. The nanowires display excellent stability while stored and handled under ambient conditions over the course of weeks. Upon optical excitation, Fabry–Pérot lasing occurs in CsPbBr3 nanowires with an onset of 5 μJ cm−2 with the nanowire cavity displaying a maximum quality factor of 1,009 ± 5. Lasing under constant, pulsed excitation can be maintained for over 1 h, the equivalent of 109 excitation cycles, and lasing persists upon exposure to ambient atmosphere. Wavelength tunability in the green and blue regions of the spectrum in conjunction with excellent stability makes these nanowire lasers attractive for device fabrication. PMID:26862172

  8. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  9. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available , there is little information on optical phase aberrations and no study to date on the propagation parameters of the laser beam, but has rather remained rooted in the domain of ray optics. Researchers revisit the spinning pipe gas lens in this paper with new...

  10. Tube entrance lens focus control

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; Kitchen, T. F. G.; Tunningley, T. B.; Lobanov, N. R.; Muirhead, A. G.

    2013-02-01

    The entrance of the accelerator tube in a large electrostatic accelerator imposes a strong lens that dominates the beam optics. The magnification of the lens is large because of the low injection energy, the high voltage gradient of the acceleration tube and the long distance to the terminal. In the absence of the acceleration, the magnification would produce an unacceptably large beam spot at the terminal. The tyranny of the lens is especially irksome when the accelerator is required to operate at a lower terminal voltage than the one corresponding to the nominal gradient at high voltage. One way around the difficulty, used in NEC Pelletron accelerators, is to insert a series of nylon and steel rods that short together units of the acceleration structure at the terminal leaving the ones near the entrance close to the nominal gradient for optimum transmission. This operation takes time and risks the loss of insulating gas. Another alternative used in the 25URC at Oak Ridge National Laboratory, is to focus the beam at the tube entrance, substantially diluting the effect of the entrance lens. The beam then diverges and so requires an additional lens part way to the terminal. This solution is only partially effective and still necessitates use of shorting rods for low voltage operation. The fact that these elaborate strategies are used is evidence that the alternative of lowering the injection energy as the terminal voltage is lowered imposes enough problems that it is not used in practice. We have modeled a solution that controls the voltage gradient at the tube entrance using an external power supply. This not only maintains the focusing effect of the lens but provides the opportunity to tune the beam by adjusting the entrance lens. A 150 kV power supply outside the pressure vessel feeds a controllable voltage through a high voltage feed-through to the fifth electrode of the accelerator tube. Thus 150 kV on this electrode creates the nominal gradient of 30 kV per

  11. Sorption behavior of cesium onto bentonite colloid

    International Nuclear Information System (INIS)

    Iijima, Kazuki; Masuda, Tsuguya; Tomura, Tsutomu

    2004-01-01

    It is considered that bentonite colloid might be generated from bentonite which will be used as buffer material in geological disposal system, and can facilitate the migration of radionuclides by means of sorption. In order to examine this characteristic, sorption and desorption experiments of Cs onto bentonite colloid were carried out to obtain its distribution coefficient (Kd) and information on the reversibility of its sorption. In addition, particle size distribution and shape of colloid were investigated and their effect on the sorption behavior was discussed. Kds for Cs were around 20 m 3 /kg for sorption and 30 m 3 /kg for desorption, in which sorbed Cs was desorbed by 8.4x10 -4 mol/l of NaCl solution. These values did not show any dependencies on Cs concentration and duration of sorption and desorption. The first 20% of sorbed Cs was desorbed reversibly at least. Most of colloidal particles were larger than 200 nm and TEM micrographs showed they had only several sheets of the clay crystal. Obtained Kds for colloidal bentonite were larger than those for powdered bentonite. This can be caused by difference of competing ions in the solution, characteristics of contained smectite, or sorption site density. (author)

  12. Cesium chemistry in GCFR fuel pins

    International Nuclear Information System (INIS)

    Fee, D.C.; Johnson, C.E.

    1979-01-01

    The fuel rod design for the Gas Cooled Fast-Breeder Reactor (GCFR) is similar to that employed for the Liquid Metal Fast Breeder Reactor (LMFBR) with the exception of the unique features inherent to the use of helium as the coolant. These unique design features include the use of (1) vented and pressure-equalized fuel rods, and (2) ribbed cladding along 75% of the fuel section. The former design feature enables reduction in cladding thickness and prevention of possible creep collapse of the cladding due to the high coolant pressure (8.5 MPa). The latter design feature brings about improved heat transfer characteristics. Each GCFR fuel rod is vented to a manifold whereby gaseous fission products diffusing out of the fuel pin are retained on charcoal traps. As a result, the internal pressure of a GCFR fuel pin does not increase during irradiation. In addition, the venting system also maintains the pressure within the fuel pin slightly below (0.3 to 0.5 MPa) the coolant pressure outside the fuel pin. Consequently, should a breach occur in the cladding, helium flows into the breached fuel pin thereby minimizing fission product contamination of the coolant. These desirable aspects of a GCFR fuel pin can be maintained only as long as axial gas transport paths are available and operating within the fuel pin

  13. Sterility and the disinfection potential of Indian contact lens solutions

    Directory of Open Access Journals (Sweden)

    Gopinathan Usha

    1994-01-01

    Full Text Available Ocular infection associated with microbial contamination of contact lens care products is a major problem in contact lens wearers. The sterility and the antimicrobial activity of contact lens care systems reflect their suitability for disinfection of contact lenses. These factors remain to be evaluated for the various newer contact lens care products manufactured in India. In this study, 35 bottles of contact lens solutions marketed by different manufacturing units in India were tested for sterility. Seven solutions were tested for antimicrobial effectiveness employing the D value method of analysis. The D value is defined as the time required to reduce a population of organisms by 90% (one log unit. A standard inoculum of the ocular isolates of Staphylococcus aureus, Pseudomonas aeruginosa, Serratia marcescens, Aspergillus fumigatus, Fusarium solani, and Acanthamoeba castellanii were used as challenge organisms. Bacterial contamination was detected in 20 (57.1% solution bottles and none yielded fungus or Acanthamoeba. Pseudomonas species were the most commonly encountered contaminant (11/20; 55%. Only sterile solutions were analyzed for antimicrobial activity. D values ranging between 12 and 20 minutes were demonstrated by six of the seven solutions against bacterial challenge. Good antifungal activity was noticed in five solutions against Fusarium solani though results varied with Aspergillus flavus and Candida albicans. All solutions were adequately effective against Acanthamoeba.

  14. Review of the Experimental Background and Implementation of Computational Models of the Ocular Lens Microcirculation.

    Science.gov (United States)

    Wu, Ho-Ting D; Donaldson, Paul J; Vaghefi, Ehsan

    2016-01-01

    Our sense of vision is critically dependent on the clarity of the crystalline lens. The most common cause of transparency loss in the lens is age-related nuclear cataract, which is due to accumulative oxidative damage to this tissue. Since the ocular lens is an avascular tissue, it has to maintain its physiological homeostasis and antioxidant levels using a system of water microcirculation. This system has been experimentally imaged in animal lenses using different modalities. Based on these data, computational models have been developed to predict the properties of this system in human lenses and its changes due to aging. Although successful in predicting many aspects of lens fluid dynamics, at least in animal models, these in-silica models still need further improvement to become more accurate and representative of human ocular lens. We have been working on gathering experimental data and simultaneously developing computational models of lens microcirculation for the past decade. This review chronologically looks at the development of data-driven computational foundations of lens microcirculation model, its current state, and future advancement directions. A comprehensive model of lens fluid dynamics is essential to understand the physiological optics of this tissue and ultimately the underlying mechanisms of cataract onset and progression.

  15. Electrowetting liquid lens array on curved substrates for wide field of view image sensor

    Science.gov (United States)

    Bang, Yousung; Lee, Muyoung; Won, Yong Hyub

    2016-03-01

    In this research, electrowetting liquid lens array on curved substrates is developed for wide field of view image sensor. In the conventional image sensing system, this lens array is usually in the form of solid state. However, in this state, the lens array which is similar to insect-like compound eyes in nature has several limitations such as degradation of image quality and narrow field of view because it cannot adjust focal length of lens. For implementation of the more enhanced system, the curved array of lenses based on electrowetting effect is developed in this paper, which can adjust focal length of lens. The fabrication of curved lens array is conducted upon the several steps, including chamber fabrication, electrode & dielectric layer deposition, liquid injection, and encapsulation. As constituent materials, IZO coated convex glass, UV epoxy (NOA 68), DI water, and dodecane are used. The number of lenses on the fabricated panel is 23 by 23 and each lens has 1mm aperture with 1.6mm pitch between adjacent lenses. When the voltage is applied on the device, it is observed that each lens is changed from concave state to convex state. From the unique optical characteristics of curved array of liquid lenses such as controllable focal length and wide field of view, we can expect that it has potential applications in various fields such as medical diagnostics, surveillance systems, and light field photography.

  16. Oral Morphine Consumption Reduces Lens Development in Rat Embryos

    Directory of Open Access Journals (Sweden)

    Hossein Bahadoran

    2012-07-01

    Full Text Available Objective: Consumption of morphine, during pregnancy, in addition to inducing defects in the mother’s nervous system function, caused defects or delays in the formation and evolution of embryonic visual system. In the present study, changes in lens development was assessed in embryos exposed in utero to morphine. Material and Methods: Female Wistar rats (250-300 g were mated with male rats and pregnancy was determined by sperm observation in vaginal smear. This day was considered as embryonic day zero (E0. The females were then divided randomly into the experimental and the control groups. The control group received tap water and the experimental group received morphine (0.05 mg/ml in their water. On embryonic day 13 ( E13, blood samples were collected from the retro-orbital sinus of all animals for plasma corticosterone detection. On embryonic day 17(E17, the animals were killed by an overdose of chloroform and the embryos were taken out surgically. The embryos were fixed in 10% formalin for 30 days. At this time, the head of the embryos were removed for tissue processing and Hematoxylin- Eosin (H&E staining. The samples were evaluated using light microscope and MOTIC software. Results: Our data indicated that plasma corticosterone level was dramatically increased and the lens was thinner in the experimental group. (Although the proliferation of lens cells increased in the experiment group but that lens had delay in removing the proliferated and elongation cells with abnormal density in the lateral part of the lens in compare with control group. I have no idea what the authors are stating here. Moreover, the opening of the eyelids was delayed in the off springs of the mothers who received morphine. Conclusions: This study showed that morphine consumption during pregnancy leads to defects in fetal visual system development, particularly in the lens, and eyelids.

  17. Measurements of the cesium flow from a surface-plasma H- ion source

    International Nuclear Information System (INIS)

    Smith, H.V.; Allison, P.W.

    1979-01-01

    A surface ionization gauge (SIG) was constructed and used to measure the Cs 0 flow rate through the emission slit of a surface-plasma source (SPS) of H - ions with Penning geometry. The equivalent cesium density in the SPS discharge is deduced from these flow measurements. For dc operation the optimum H - current occurs at an equivalent cesium density of approx. 7 x 10 12 cm -3 (corresponding to an average cesium consumption rate of 0.5 mg/h). For pulsed operation the optimum H - current occurs at an equivalent cesium density of approx. 2 x 10 13 cm -3 (1-mg/h average cesium consumption rate). Cesium trapping by the SPS discharge was observed for both dc and pulsed operation. A cesium energy of approx. 0.1 eV is deduced from the observed time of flight to the SIG. In addition to providing information on the physics of the source, the SIG is a useful diagnostic tool for source startup and operation

  18. Equilibrium, kinetic and thermodynamic study of cesium adsorption onto nanocrystalline mordenite from high-salt solution.

    Science.gov (United States)

    Lee, Keun-Young; Park, Minsung; Kim, Jimin; Oh, Maengkyo; Lee, Eil-Hee; Kim, Kwang-Wook; Chung, Dong-Yong; Moon, Jei-Kwon

    2016-05-01

    In this study, the equilibrium, kinetics and thermodynamics of cesium adsorption by nanocrystalline mordenite were investigated under cesium contamination with high-salt solution, simulating the case of an operation and decommissioning of nuclear facilities or an accident during the processes. The adsorption rate constants were determined using a pseudo second-order kinetic model. The kinetic results strongly demonstrated that the cesium adsorption rate of nano mordenite is extremely fast, even in a high-salt solution, and much faster than that of micro mordenite. In the equilibrium study, the Langmuir isotherm model fit the cesium adsorption data of nano mordenite better than the Freundlich model, which suggests that cesium adsorption onto nano mordenite is a monolayer homogeneous adsorption process. The obtained thermodynamic parameters indicated that the adsorption involved a very stable chemical reaction. In particular, the combination of rapid particle dispersion and rapid cesium adsorption of the nano mordenite in the solution resulted in a rapid and effective process for cesium removal without stirring, which may offer great advantages for low energy consumption and simple operation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Fast concentration of dissolved forms of cesium radioisotopes from large seawater samples

    International Nuclear Information System (INIS)

    Jan Kamenik; Henrieta Dulaiova; Ferdinand Sebesta; Kamila St'astna; Czech Technical University, Prague

    2013-01-01

    The method developed for cesium concentration from large freshwater samples was tested and adapted for analysis of cesium radionuclides in seawater. Concentration of dissolved forms of cesium in large seawater samples (about 100 L) was performed using composite absorbers AMP-PAN and KNiFC-PAN with ammonium molybdophosphate and potassium–nickel hexacyanoferrate(II) as active components, respectively, and polyacrylonitrile as a binding polymer. A specially designed chromatography column with bed volume (BV) 25 mL allowed fast flow rates of seawater (up to 1,200 BV h -1 ). The recovery yields were determined by ICP-MS analysis of stable cesium added to seawater sample. Both absorbers proved usability for cesium concentration from large seawater samples. KNiFC-PAN material was slightly more effective in cesium concentration from acidified seawater (recovery yield around 93 % for 700 BV h -1 ). This material showed similar efficiency in cesium concentration also from natural seawater. The activity concentrations of 137 Cs determined in seawater from the central Pacific Ocean were 1.5 ± 0.1 and 1.4 ± 0.1 Bq m -3 for an offshore (January 2012) and a coastal (February 2012) locality, respectively, 134 Cs activities were below detection limit ( -3 ). (author)

  20. Development of a 3D finite element model of lens microcirculation

    Directory of Open Access Journals (Sweden)

    Vaghefi Ehsan

    2012-09-01

    Full Text Available Abstract Background It has been proposed that in the absence of a blood supply, the ocular lens operates an internal microcirculation system. This system delivers nutrients, removes waste products and maintains ionic homeostasis in the lens. The microcirculation is generated by spatial differences in membrane transport properties; and previously has been modelled by an equivalent electrical circuit and solved analytically. While effective, this approach did not fully account for all the anatomical and functional complexities of the lens. To encapsulate these complexities we have created a 3D finite element computer model of the lens. Methods Initially, we created an anatomically-correct representative mesh of the lens. We then implemented the Stokes and advective Nernst-Plank equations, in order to model the water and ion fluxes respectively. Next we complemented the model with experimentally-measured surface ionic concentrations as boundary conditions and solved it. Results Our model calculated the standing ionic concentrations and electrical potential gradients in the lens. Furthermore, it generated vector maps of intra- and extracellular space ion and water fluxes that are proposed to circulate throughout the lens. These fields have only been measured on the surface of the lens and our calculations are the first 3D representation of their direction and magnitude in the lens. Conclusion Values for steady state standing fields for concentration and electrical potential plus ionic and fluid fluxes calculated by our model exhibited broad agreement with observed experimental values. Our model of lens function represents a platform to integrate new experimental data as they emerge and assist us to understand how the integrated structure and function of the lens contributes to the maintenance of its transparency.

  1. Time lens assisted photonic sampling extraction

    Science.gov (United States)

    Petrillo, Keith Gordon

    Telecommunication bandwidth demands have dramatically increased in recent years due to Internet based services like cloud computing and storage, large file sharing, and video streaming. Additionally, sensing systems such as wideband radar, magnetic imaging resonance systems, and complex modulation formats to handle large data transfer in telecommunications require high speed, high resolution analog-to-digital converters (ADCs) to interpret the data. Accurately processing and acquiring the information at next generation data rates from these systems has become challenging for electronic systems. The largest contributors to the electronic bottleneck are bandwidth and timing jitter which limit speed and reduce accuracy. Optical systems have shown to have at least three orders of magnitude increase in bandwidth capabilities and state of the art mode locked lasers have reduced timing jitters into thousands of attoseconds. Such features have encouraged processing signals without the use of electronics or using photonics to assist electronics. All optical signal processing has allowed the processing of telecommunication line rates up to 1.28 Tb/s and high resolution analog-to-digital converters in the 10s of gigahertz. The major drawback to these optical systems is the high cost of the components. The application of all optical processing techniques such as a time lens and chirped processing can greatly reduce bandwidth and cost requirements of optical serial to parallel converters and push photonically assisted ADCs into the 100s of gigahertz. In this dissertation, the building blocks to a high speed photonically assisted ADC are demonstrated, each providing benefits to its own respective application. A serial to parallel converter using a continuously operating time lens as an optical Fourier processor is demonstrated to fully convert a 160-Gb/s optical time division multiplexed signal to 16 10-Gb/s channels with error free operation. Using chirped processing, an

  2. Development of a Laue lens for nuclear astrophysics

    International Nuclear Information System (INIS)

    Barriere, N.

    2008-04-01

    The Laue lenses we study focuses in the domain of 0.1-1 MeV thanks to Bragg diffraction in the volume of a large number of small crystal tiles. The focal length of a typical Laue lens system is of the order of 100 m. This requirement calls for two formation flying satellites maintaining lens and detector at the focal distance. The major breakthrough of Laue lenses is to decouple collecting area from detector area. Concentrating a signal from the large area of a Laue lens onto a small focal spot dramatically increases the signal over background ratio with respect to present technologies. Here is the reason for the long awaited leap in sensitivity. The objective of the present thesis was to improve the concept, finding viable technical solutions towards a future space mission. Two aspects of the lens development have been highlighted in this thesis: the first one is an analytical model of the lens that is used to calculate and improve the performance of a certain configuration, the second aspect concerns the search and the characterization of diffracting media of interest. The lens model developed relies on a fast semi-analytical simulation library, permitting to build several design- and optimisation-tools. For the configuration of a given lens, this code computes the resulting effective area and point spread function in a handful of seconds. The model helps finding lens configurations (mass, pack ratio of the lens rings,...) which are automatically refined to match with effective area and energy coverage constraints. These tools have been used to investigate various design aspects, such as the influence of focal length, size, mosaic spread, structure and materials of crystals, etc... The central evaluation criterion in the model is a figure of merit, based on the compactness of the focal spot and the intensity of the collected signal. The second part of this work addresses the actual search and characterization of crystals potentially interesting for Laue lenses

  3. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  4. Bilateral ectopia lentis with isolated lens coloboma in Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Sahu, Sabin

    2016-12-01

    Full Text Available A rare case of bilateral ectopia lentis with isolated lens coloboma in Marfan syndrome is reported. A 21-year-old female presented with decreased vision in both eyes. Her unaided visual acuity was 20/200 and 20/400 in the right and left eye, respectively, improving to 20/40 with –4.5 DS/–3.0 DC x 10° correction in the right eye and 20/80 with –10.0 DS/–6.5 Dc x10° correction in the left eye. On slit lamp examination under mydriasis, both eyes revealed ectopia lentis with lens coloboma and stretched zonules. Fundus examination revealed pigmentary changes at the fovea. On systemic evaluation, she was diagnosed with Marfan syndrome. She was prescribed a refractive correction in form of a contact lens and kept under observation.

  5. Laser Tweezer Controlled Solid Immersion Lens for High Resolution Imaging in Microfluidic and Biological Samples

    National Research Council Canada - National Science Library

    Birkbeck, Aaron L; Zlatanovic, Sanja; Ozkan, Mihrimah; Esener, Sadik C

    2005-01-01

    ...). Up to now, solid immersion lens imaging systems have relied upon cantilever-mounted SILs that are difficult to integrate into microfluidic systems and require an extra alignment step with external optics...

  6. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  7. Test procedures and instructions for single shell tank saltcake cesium removal with crystalline silicotitanate

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, J.B.

    1997-01-07

    This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test, using Hanford Single Shell Tank Saltcake from tanks 24 t -BY- I 10, 24 1 -U- 108, 24 1 -U- 109, 24 1 -A- I 0 1, and 24 t - S-102, in a bench-scale column. The cesium sorbent to be tested is crystalline siticotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-024, Hanford Single Shell Tank Saltcake Cesium Removal Test Plan.

  8. Historical Cost Curves for Hydrogen Masers and Cesium Beam Frequency and Timing Standards

    Science.gov (United States)

    Remer, D. S.; Moore, R. C.

    1985-01-01

    Historical cost curves were developed for hydrogen masers and cesium beam standards used for frequency and timing calibration in the Deep Space Network. These curves may be used to calculate the cost of future hydrogen masers or cesium beam standards in either future or current dollars. The cesium beam standards are decreasing in cost by about 2.3% per year since 1966, and hydrogen masers are decreasing by about 0.8% per year since 1978 relative to the National Aeronautics and Space Administration inflation index.

  9. Effects of mineralogy on sorption of strontium and cesium onto Calico Hills Tuff

    International Nuclear Information System (INIS)

    Meyer, R.E.; Arnold, W.D.; Case, F.I.; O'Kelley, G.D.; Land, J.F.

    1990-04-01

    The sorption properties of tuff formations at the proposed site for the high-level nuclear waste repository at Yucca Mountain, Nevada, have been extensively studied. Sorption and desorption measurements were made of strontium and cesium onto clinoptilolite and Calico Hills Tuff. The object was to see whether there was a correlation between sorption of strontium and cesium onto Calico Hills Tuff and the sorption of strontium and cesium onto clinoptilolite based on the content of clinoptilolite in the Calico Hills Tuff. 13 refs., 10 figs., 6 tabs

  10. First-principles study of cesium adsorption to weathered micaceous clay minerals

    Science.gov (United States)

    Okumura, Masahiko; Nakamura, Hiroki; Machida, Masahiko

    2014-05-01

    A large amount of radioactive nuclides was produced into environment due to the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident. Residents near FDNPP were suffering from radioactive cesium and then evacuated, because which has long half-life and is retained by surface soil for long time. The Japanese government has been decontaminating the cesium by removing the surface soil in order to return them to their home. This decontamination method is very effective, but which produces huge amount of waste soil. This becomes another big problem in Fukushima, because it is not easy to find large storage sites. Then effective and economical methods to reduce the volume of the waste soil are needed. However, it has not been invented yet. One of the reasons is lack of knowledge about microscopic process of adsorption/desorption of cesium to/from soil. It is known that weathered micaceous clay minerals play crucial role on adsorption and retention of cesium. They are expected to have special sorption sites, called frayed edge sites (FESs), which adsorb cesium selectively and irreversibly. Properties of FES have been intensely investigated by experiments. But microscopic details of the adsorption process on FES are still unclear. Because direct observation of the process with current experimental techniques is quite difficult. We investigated the adsorption of cesium to FES in muscovite, which is a typical micaceous clay mineral, via first-principles calculations (density functional theory). We made a minimal model of FES and evaluate the energy difference before and after cesium adsorption to FES. This is the first numerical modeling of FES. It was shown that FES does adsorb cesium if the weathering of muscovite has been weathered. In addition, we revealed the mechanism of cesium adsorption to FES, which is competition between ion radius of cesium and the degree of weathering. I plan to discuss volume reduction of the waste soil based on our result. Reference M. Okumura

  11. Radioactive and Stable Cesium Distributions in Fukushima Forests

    Science.gov (United States)

    Ioshchenko, V.; Kivva, S.; Konoplev, A.; Nanba, K.; Onda, Y.; Takase, T.; Zheleznyak, M.

    2015-12-01

    Fukushima Dai-ichi NPP accident has resulted in release into the environment of large amounts of 134Cs and 137Cs and in radioactive contamination of terrestrial and aquatic ecosystems. In Fukushima prefecture up to 2/3 of the most contaminated territory is covered with forests, and understanding of its further fate in the forest ecosystems is essential for elaboration of the long-term forestry strategy. At the early stage, radiocesium was intercepted by the trees' canopies. Numerous studies reported redistribution of the initial fallout in Fukushima forests in the followed period due to litterfall and leaching of radiocesium from the foliage with precipitations. By now these processes have transported the major part of deposited radiocesium to litter and soil compartments. Future levels of radiocesium activities in the aboveground biomass will depend on relative efficiencies of the radiocesium root uptake and its return to the soil surface with litterfall and precipitations. Radiocesium soil-to-plant transfer factors for typical tree species, soil types and landscape conditions of Fukushima prefecture have not been studied well; moreover, they may change in time with approaching to the equilibrium between radioactive and stable cesium isotopes in the ecosystem. The present paper reports the results of several ongoing projects carried out by Institute of Environmental Radioactivity of Fukushima University at the experimental sites in Fukushima prefecture. For typical Japanese cedar (Cryptomeria japonica) forest, we determined distributions of radiocesium in the ecosystem and in the aboveground biomass compartments by the end of 2014; available results for 2015 are presented, too, as well as the results of test application of D-shuttle dosimeters for characterization of seasonal variations of radiocesium activity in wood. Based on the radiocesium activities in biomass we derived the upper estimates of its incorporation and root uptake fluxes, 0.7% and 3% of the total

  12. Qualification of a Null Lens Using Image-Based Phase Retrieval

    Science.gov (United States)

    Bolcar, Matthew R.; Aronstein, David L.; Hill, Peter C.; Smith, J. Scott; Zielinski, Thomas P.

    2012-01-01

    In measuring the figure error of an aspheric optic using a null lens, the wavefront contribution from the null lens must be independently and accurately characterized in order to isolate the optical performance of the aspheric optic alone. Various techniques can be used to characterize such a null lens, including interferometry, profilometry and image-based methods. Only image-based methods, such as phase retrieval, can measure the null-lens wavefront in situ - in single-pass, and at the same conjugates and in the same alignment state in which the null lens will ultimately be used - with no additional optical components. Due to the intended purpose of a Dull lens (e.g., to null a large aspheric wavefront with a near-equal-but-opposite spherical wavefront), characterizing a null-lens wavefront presents several challenges to image-based phase retrieval: Large wavefront slopes and high-dynamic-range data decrease the capture range of phase-retrieval algorithms, increase the requirements on the fidelity of the forward model of the optical system, and make it difficult to extract diagnostic information (e.g., the system F/#) from the image data. In this paper, we present a study of these effects on phase-retrieval algorithms in the context of a null lens used in component development for the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission. Approaches for mitigation are also discussed.

  13. A theoretical lens for revealing the complexity of chronic care

    NARCIS (Netherlands)

    Borgermans, L.; de Maeseneer, J.; Wollersheim, H.; Vrijhoef, H.J.M.; Devroey, D.

    2013-01-01

    The increasing prevalence of co-occurring multiple chronic conditions in an aging population has influenced the debate on complexity in chronic care and nowadays provides an impetus to the reform of numerous health systems. This article presents a theoretical lens for understanding the complexity of

  14. Forgotten Forests? Food Potential of Ancient Coffee Forests and Agroforestry Systems in the Southwestern Ethiopian Mountains, Seen Through a Gender Lens

    Directory of Open Access Journals (Sweden)

    Sarah Marie Nischalke

    2017-08-01

    Full Text Available Forests play an important role in the provision of food and livelihoods across the globe. Thus, forest protection contributes to a diverse set of Sustainable Development Goals. The Yayu Coffee Forest Biosphere Reserve in the southwestern Ethiopian mountains (elevation 1100–2300 m above sea level hosts an ancient coffee forest with high biodiversity and a large nutritional potential. It is managed in zones, and smallholder farmers can still use forest resources in the buffer and transitional zones in a sustainable manner. The forest is rarely used as a food source, although a large majority of the population in this area suffers from micronutrient deficiencies. This article investigates whether sustainable use of forest resources can contribute to the achievement of different Sustainable Development Goals by looking, through a gender lens, at which forest ecosystem services the community uses; traditional coffee farmers' perceptions of wild edible plants, agricultural territories, and labor divisions; and the constraining factors for forest conservation and sustainable agroforestry on private forest plots. Data for this study were collected through ethnography, transect walks, a sex-disaggregated household survey (n = 334, 32 semistructured interviews, 40 focus groups, and 13 key stakeholder interviews. One reason for neglecting the forest as a food source is that forests are considered a male territory, while vegetable raising and nutrition are female responsibilities. In addition, the collection of wild foods is perceived as a last resort during a famine and as a practice of tribal groups. Because coffee production represents the traditional livelihood source, farmers accept the need to conserve the forest, which is necessary to achieve the Sustainable Development Goals. While it may have negative implications for food security, the absence of a tradition of collecting wild plants is positive news for forest conservation.

  15. Resistance force for intraocular lens insertion through lens cartridges and syringe-type injectors.

    Science.gov (United States)

    Usui, Masahiko; Tanaka, Takao

    2015-08-01

    To measure and compare the resistance force for intraocular lens (IOL) insertion using 5 syringe-type injector systems. Tokyo Medical University and laboratory in Kowa Co., Tokyo, Japan. Experimental study. Intraocular lenses were inserted into the lens capsular bag of porcine eyes after phacoemulsification using 5 implantation systems (Groups A, B, C, D, and E). For each system, the resistance force for IOL insertion to the lens capsular bag of porcine eyes was measured using an automated force gauge system. For control, the resistance force for IOL delivery into a plastic dish was measured. Changes in the resistance force and its curve and maximum value were evaluated. The mean total area under the curve (AUC) was compared. Data were statistically analyzed. For all groups, the mean resistance forces were 17.2, 6.3, 4.2, 20.7, and 2.3 newtons (N), respectively, in porcine eyes, and 14.4, 5.8, 4.5, 12.6, and 2.2 N in controls. The mean sizes of the total AUC were 43 371, 8465, 6771, 30 306, and 2334 pixels in porcine eyes and 40 940, 7080, 6876, 20 710, and 2215 pixels in controls; the correlation coefficients between the resistance forces and the sizes of the total area were 0.576, 0.113, 0.346, 0.726, and 0.933 in porcine eyes and 0.707, 0.557, 0.914, 0.951, and 0.893 in controls. Resistance force and its curve were clarified in 5 IOL implantation systems. Appropriate IOL and injector selection may be achieved after clarifying resistance force and its waveform during IOL insertion. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015. Published by Elsevier Inc.

  16. Norbadione A: synthetic approach and cesium complexation studies

    International Nuclear Information System (INIS)

    Desage - El Murr, M.

    2003-10-01

    This work was dedicated to the study of the synthesis and complexation studies of norbadione A: a pigment originating from a mushroom. A synthetic approach, based on a double Suzuki-Miyaura coupling, was developed. This strategy was applied with high yields to the synthesis of various norbadione A analogues, as well as to the synthesis of simple pulvinic acids. Access to functionalized precursors of the molecule was also studied and the final coupling remains to be done. Besides, a speciation study based on electro-spray ionization mass spectrometry was conducted with norbadione A and one of the analogues. This study allowed the assessment of the cesium complexation abilities of each molecule. Structural data was also obtained and complexation constants were calculated. Finally, norbadione A and various synthetic products have been tested via high-throughput screening methods and strong antioxidant properties were observed. Other biological results are also reported. (author)

  17. Decreasing radioactive cesium in lodged buckwheat grain after harvest

    Directory of Open Access Journals (Sweden)

    Katashi Kubo

    2016-01-01

    Full Text Available This study assessed soil contamination with high radioactive cesium (R–Cs concentration in buckwheat grains by lodging, and assessed the possibility of R–Cs reduction in grain through post-harvest preparation. Analysis of buckwheat grain produced in farmers’ fields and reports from farmers indicated that grain from fields that had lodging showed higher R–Cs than grain from fields with no lodging. A field experiment demonstrated that R–Cs in grain after threshing and winnowing (TW was about six times higher in lodged plants than in nonlodged plants. In lodged plants, R–Cs in grain was decreased to about one-fourth by polishing, and was decreased to about one-seventh by ultrasonic cleaning, compared with R–Cs in grain after TW. These results demonstrate that R–Cs of buckwheat grain of lodged plants can be decreased by removing soil from the grain surface by polishing and winnowing.

  18. Quality assurance program plan for cesium legacy project

    International Nuclear Information System (INIS)

    Tanke, J.M.

    1997-01-01

    This Quality Assurance Program Plan (QAPP) provides information on how the Quality Assurance Program is implemented for the Cesium Legacy Project. It applies to those items and tasks which affect the completion of activities identified in the work breakdown structure of the Project Management Plan (PMP). These activities include all aspects of cask transportation, project related operations within the 324 Building, and waste management as it relates to the specific activities of this project. General facility activities (i.e. 324 Building Operations, Central Waste Complex Operations, etc.) are covered in other appropriate QAPPs. The 324 Building is currently transitioning from being a Pacific Northwest National Laboratory (PNNL) managed facility to a B and W Hanford Company (BWHC) managed facility. During this transition process existing PNNL procedures and documents will be utilized until replaced by BWHC procedures and documents

  19. Estimating soil erosion losses in Korea with fallout cesium-137

    International Nuclear Information System (INIS)

    Menzel, R.G.; Pilkyun Jung; Kwanshig Ryu; Kitai Um

    1987-01-01

    The contents of fallout 137 Cs in soil profiles were used to estimate erosion losses from steeply sloping croplands in Korea. Seven undisturbed sites with no apparent erosion or deposition, and 15 cropland sites were examined to a depth of 30 cm. The cropland sites had been cultivated for periods ranging from 5 to more than 80 y (median 10 y), and their slopes ranged from 5 to 26% (median 13%). All except one of the cropland sites contained less 137 Cs than undisturbed sites in the same area. Three cropland sites contained essentially no 137 Cs, indicating erosion of the entire cultivated layer of soil in from 6 to 10 years. Other cropland sites, particularly those with sandy texture, showed little loss of 137 Cs over longer periods of cultivation. Cesium-137 measurements may be useful in identifying site characteristics that reduce the vulnerability of sloping soils to erosion damage. (author)

  20. Cesium-137 accident lessons in Goiania, Goias State, Brazil

    International Nuclear Information System (INIS)

    1990-11-01

    This document relates the experience obtained by several professionals which had an important role in the cesium-137 accident occurred in Goiania, Goias State, Brazil in September, 1987. It's divided into chapters, according to the action area - medical, nursing, social assistance, odontological and psychological. At first, some notions of radioprotection are explained, followed by the accident history and by the doctors and nurses action during the emergency phase and the medical, odontological, social and psychological assistance to the victims. The social assistance report shows some statistical data about the economic, occupational and social conditions of the accident victims. It is shown some information about the health institutions and the sanitary care in the ionizing radiation and about the occupational radiological protection in Goiania