WorldWideScience

Sample records for length measurement system

  1. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  2. An Imaging System for Automated Characteristic Length Measurement of Debrisat Fragments

    Science.gov (United States)

    Moraguez, Mathew; Patankar, Kunal; Fitz-Coy, Norman; Liou, J.-C.; Sorge, Marlon; Cowardin, Heather; Opiela, John; Krisko, Paula H.

    2015-01-01

    The debris fragments generated by DebriSat's hypervelocity impact test are currently being processed and characterized through an effort of NASA and USAF. The debris characteristics will be used to update satellite breakup models. In particular, the physical dimensions of the debris fragments must be measured to provide characteristic lengths for use in these models. Calipers and commercial 3D scanners were considered as measurement options, but an automated imaging system was ultimately developed to measure debris fragments. By automating the entire process, the measurement results are made repeatable and the human factor associated with calipers and 3D scanning is eliminated. Unlike using calipers to measure, the imaging system obtains non-contact measurements to avoid damaging delicate fragments. Furthermore, this fully automated measurement system minimizes fragment handling, which reduces the potential for fragment damage during the characterization process. In addition, the imaging system reduces the time required to determine the characteristic length of the debris fragment. In this way, the imaging system can measure the tens of thousands of DebriSat fragments at a rate of about six minutes per fragment, compared to hours per fragment in NASA's current 3D scanning measurement approach. The imaging system utilizes a space carving algorithm to generate a 3D point cloud of the article being measured and a custom developed algorithm then extracts the characteristic length from the point cloud. This paper describes the measurement process, results, challenges, and future work of the imaging system used for automated characteristic length measurement of DebriSat fragments.

  3. Microscopic optical path length difference and polarization measurement system for cell analysis

    Science.gov (United States)

    Satake, H.; Ikeda, K.; Kowa, H.; Hoshiba, T.; Watanabe, E.

    2018-03-01

    In recent years, noninvasive, nonstaining, and nondestructive quantitative cell measurement techniques have become increasingly important in the medical field. These cell measurement techniques enable the quantitative analysis of living cells, and are therefore applied to various cell identification processes, such as those determining the passage number limit during cell culturing in regenerative medicine. To enable cell measurement, we developed a quantitative microscopic phase imaging system based on a Mach-Zehnder interferometer that measures the optical path length difference distribution without phase unwrapping using optical phase locking. The applicability of our phase imaging system was demonstrated by successful identification of breast cancer cells amongst normal cells. However, the cell identification method using this phase imaging system exhibited a false identification rate of approximately 7%. In this study, we implemented a polarimetric imaging system by introducing a polarimetric module to one arm of the Mach-Zehnder interferometer of our conventional phase imaging system. This module was comprised of a quarter wave plate and a rotational polarizer on the illumination side of the sample, and a linear polarizer on the optical detector side. In addition, we developed correction methods for the measurement errors of the optical path length and birefringence phase differences that arose through the influence of elements other than cells, such as the Petri dish. As the Petri dish holding the fluid specimens was transparent, it did not affect the amplitude information; however, the optical path length and birefringence phase differences were affected. Therefore, we proposed correction of the optical path length and birefringence phase for the influence of elements other than cells, as a prerequisite for obtaining highly precise phase and polarimetric images.

  4. Round-Trip System Available to Measure Path Length Variation in Korea VLBI System for Geodesy

    Science.gov (United States)

    Oh, Hongjong; Kondo, Tetsuro; Lee, Jinoo; Kim, Tuhwan; Kim, Myungho; Kim, Suchul; Park, Jinsik; Ju, Hyunhee

    2010-01-01

    The construction project of Korea Geodetic VLBI officially started in October 2008. The construction of all systems will be completed by the end of 2011. The project was named Korea VLBI system for Geodesy (KVG), and its main purpose is to maintain the Korea Geodetic Datum. In case of the KVG system, an observation room with an H-maser frequency standard is located in a building separated from the antenna by several tens of meters. Therefore KVG system will adopt a so-called round-trip system to transmit reference signals to the antenna with reduction of the effect of path length variations. KVG s round-trip system is designed not only to use either metal or optical fiber cables, but also to measure path length variations directly. We present this unique round trip system for KVG.

  5. Laser interferometry in length measurement. Proceedings. Laserinterferometrie in der Laengenmesstechnik. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    Wavelength-stabilized lasers for length measurement, measurements of the refractive index of air, laser interferometers, acceptance tests of laser interferometer systems, the Michelson interferometer with semiconductor laser, and the state of the art of optical gyroscopes for angular position measurement are described in the general section. The examples of laser interferometer applications in production engineering comprise automatic acceptance testing of coordinate measuring systems, simultaneous laser measurements of the position and the pitching, yansing and rolling angles along a measuring line, a 3D-interferometer length measuring system, the calibration of standard measures, angular position measurements, straightness measurements, and laser interferometers as installed length measuring systems in machine tools and measuring machinery. There are no separate records of the 13 lectures presented at the meeting. (DG).

  6. Bunch length measurements in the SLC damping ring

    International Nuclear Information System (INIS)

    Decker, F.J.; Limberg, T.; Minty, M.; Ross, M.

    1993-05-01

    The synchrotron light of the SLC damping ring was used to measure the bunch length with a streak camera at different times in the damping cycle. There are bunch length oscillations after injection, different equilibrium length during the cycle due to rf manipulations to avoid microwave instability oscillations, and just before extraction there is a longitudinal phase space rotation (bunch muncher) to shorten the bunch length. Measurements under these different conditions are presented and compared with BPM pulse height signals. Calibration and adjustment issues and the connection of the streak camera to the SLC control system are also discussed

  7. Microcomputer system for controlling fuel rod length

    International Nuclear Information System (INIS)

    Meyer, E.R.; Bouldin, D.W.; Bolfing, B.J.

    1979-01-01

    A system is being developed at the Oak Ridge National Laboratory (ORNL) to automatically measure and control the length of fuel rods for use in a high temperature gas-cooled reactor (HTGR). The system utilizes an LSI-11 microcomputer for monitoring fuel rod length and for adjusting the primary factor affecting length. Preliminary results indicate that the automated system can maintain fuel rod length within the specified limits of 1.940 +- 0.040 in. This system provides quality control documentation and eliminates the dependence of the current fuel rod molding process on manual length control. In addition, the microcomputer system is compatible with planned efforts to extend control to fuel rod fissile and fertile material contents

  8. Electron Bunch Length Measurement for LCLS at SLAC

    International Nuclear Information System (INIS)

    Zelazny, M.; Allison, S.; Chevtsov, Sergei; Emma, P.; Kotturi, K.d.; Loos, H.; Peng, S.; Rogind, D.; Straumann, T.

    2007-01-01

    At Stanford Linear Accelerator Center (SLAC) a Bunch Length Measurement system has been developed to measure the length of the electron bunch for its new Linac Coherent Light Source (LCLS). This destructive measurement uses a transverse-mounted RF deflector (TCAV) to vertically streak the electron beam and an image taken with an insertable screen and a camera. The device control software was implemented with the Experimental Physics and Industrial Control System (EPICS) toolkit. The analysis software was implemented in Matlab(trademark) using the EPICS/Channel Access Interface for Scilab(trademark) and Matlab(trademark) (labCA). This architecture allowed engineers and physicists to develop and integrate their control and analysis without duplication of effort

  9. Automated path length and M56 measurements at Jefferson Lab

    International Nuclear Information System (INIS)

    Hardy, D.; Tang, J.; Legg, R.

    1997-01-01

    Accurate measurement of path length and path length changes versus momentum (M 56 ) are critical for maintaining minimum beam energy spread in the CEBAF (Continuous Electron Beam Accelerator Facility) accelerator at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The relative path length for each circuit of the beam (1256m) must be equal within 1.5 degrees of 1497 MHz RF phase. A relative path length measurement is made by measuring the relative phases of RF signals from a cavity that is separately excited for each pass of a 4.2 μs pulsed beam. This method distinguishes the path length to less than 0.5 path length error. The development of a VME based automated measurement system for path length and M 56 has contributed to faster machine setup time and has the potential for use as a feedback parameter for automated control

  10. The Accuracy of the Digital imaging system and the frequency dependent type apex locator in root canal length measurement

    International Nuclear Information System (INIS)

    Lee, Byoung Rib; Park, Chang Seo

    1998-01-01

    In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora (digital imaging system) and Root ZX (the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems, whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with no 15, no 20, no 25 files by 3 different dentists each using the periapical radiography, Digora and Root ZX. The measurements were then compared with the true length. The results were as follows ; 1. In comparing mean discrepancies between measurements obtained by using periapical radiography (mean error : -0.449 ± 0.444 mm), Digora (mean error : -0.417 ± 0.415 mm) and Root ZX (mean error : 0.123 ± 0.458 mm) with true length, periapical radiography and Digora system had statistically significant differences (p 0.05). 2. By subtracting values obtained by using periapical radiography, Digora and Root ZX from the true length and making a distribution table of their absolute values, the following analysis was possible. In the case of periapical film, 140 out of 261 (53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm, 151 out of 261 (53,6%) were acceptable in the Digora system while Root ZX had 197 out of 261 (75.5%) within the limits of 0.5 mm margin of error. 3. In determining whether the thickness of

  11. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    Science.gov (United States)

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. CEBAF Upgrade Bunch Length Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Mahmoud [Old Dominion Univ., Norfolk, VA (United States)

    2016-05-01

    Many accelerators use short electron bunches and measuring the bunch length is important for efficient operations. CEBAF needs a suitable bunch length because bunches that are too long will result in beam interruption to the halls due to excessive energy spread and beam loss. In this work, bunch length is measured by invasive and non-invasive techniques at different beam energies. Two new measurement techniques have been commissioned; a harmonic cavity showed good results compared to expectations from simulation, and a real time interferometer is commissioned and first checkouts were performed. Three other techniques were used for measurements and comparison purposes without modifying the old procedures. Two of them can be used when the beam is not compressed longitudinally while the other one, the synchrotron light monitor, can be used with compressed or uncompressed beam.

  13. Electro-Magnetic Bunch Length Measurement in LEP

    CERN Document Server

    Vos, L

    1998-01-01

    Bunch lengths between 3 and 12 mm have been measured routinely in LEP in 1997 with a small (7 mm diameter) button electrode. The measurement method is based on the spectral analysis of the electrode signal and relies on the fact that the transfer function of the complete set-up, including the signal cable, can be computed rather exactly thus eliminating the need for external calibration. The information of beam intensity is recovered as a by-product. It provides an interesting internal validation of the measurement by comparison with the normal intensity measurement. The system has been used to detect subtle but real bunch length changes with bunch intensity which can be attributed to the inductive impedance in LEP. A value for the imaginary (inductive) longitudinal impedance is derived from the observations. An indication for the resistive part of the impedance is given as well.

  14. Water absorption length measurement with the ANTARES optical beacon system

    International Nuclear Information System (INIS)

    Yepes-Ramirez, Harold

    2011-01-01

    ANTARES is a neutrino telescope located in the Mediterranean Sea with the aim of detecting high energy neutrinos of extra-terrestrial origin. It consists of a three dimensional array on 12 detection lines of photomultiplier tubes (PMTs) able to detect the Cherenkov light induced by muons produced in the interaction of neutrinos with the surrounding water and seabed. To reach the best angular resolution, good time and positioning calibrations are required. The propagation of Cherenkov photons strongly depends on the optical properties of the sea water, which has an impact on the reconstruction efficiency. The determination of the optical parameters, as the absorption and scattering lengths, is crucial to calculate properly the effective area and the angular resolution of the detector. The ANTARES optical beacon system consists of pulsed and fast, well controlled light sources distributed throughout the detector to carry out in situ the relative time calibration of the detector components. In this contribution we show some results on the sea water optical properties and their stability measured with the optical beacon system.

  15. Overview of bunch length measurements

    International Nuclear Information System (INIS)

    Lumpkin, A. H.

    1999-01-01

    An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed

  16. Measuring Crack Length in Coarse Grain Ceramics

    Science.gov (United States)

    Salem, Jonathan A.; Ghosn, Louis J.

    2010-01-01

    Due to a coarse grain structure, crack lengths in precracked spinel specimens could not be measured optically, so the crack lengths and fracture toughness were estimated by strain gage measurements. An expression was developed via finite element analysis to correlate the measured strain with crack length in four-point flexure. The fracture toughness estimated by the strain gaged samples and another standardized method were in agreement.

  17. Design and validation of a 3D virtual reality desktop system for sonographic length and volume measurements in early pregnancy evaluation.

    Science.gov (United States)

    Baken, Leonie; van Gruting, Isabelle M A; Steegers, Eric A P; van der Spek, Peter J; Exalto, Niek; Koning, Anton H J

    2015-03-01

    To design and validate a desktop virtual reality (VR) system, for presentation and assessment of volumetric data, based on commercially off-the-shelf hardware as an alternative to a fully immersive CAVE-like I-Space VR system. We designed a desktop VR system, using a three-dimensional (3D) monitor and a six degrees-of-freedom tracking system. A personal computer uses the V-Scope (Erasmus MC, Rotterdam, The Netherlands) volume-rendering application, developed for the I-Space, to create a hologram of volumetric data. Inter- and intraobserver reliability for crown-rump length and embryonic volume measurements are investigated using Bland-Altman plots and intraclass correlation coefficients. Time required for the measurements was recorded. Comparing the I-Space and the desktop VR system, the mean difference for crown-rump length is -0.34% (limits of agreement -2.58-1.89, ±2.24%) and for embryonic volume -0.92% (limits of agreement -6.97-5.13, ±6.05%). Intra- and interobserver intraclass correlation coefficients of the desktop VR system were all >0.99. Measurement times were longer on the desktop VR system compared with the I-Space, but the differences were not statistically significant. A user-friendly desktop VR system can be put together using commercially off-the-shelf hardware at an acceptable price. This system provides a valid and reliable method for embryonic length and volume measurements and can be used in clinical practice. © 2014 Wiley Periodicals, Inc.

  18. Impact of Cyclic Prefix length on OFDM system Capacity

    DEFF Research Database (Denmark)

    Rom, Christian; Sørensen, Troels Bundgaard; Mogensen, Preben Elgaard

    2005-01-01

    This paper is a study on the impact of the Cyclic Prefix (CP) length on the downlink Capacity in a base-band synchronized SISO-OFDM context. To measure this impact, the capacity, measured in bits per second per hertz, is chosen as quality parameter. The study shows how the lengthening of the CP......) the useful OFDM symbol duration, 2) the Signal to Noise Ratio (SNR) at the receiver and 3) the channel Power Delay Profile (PDP). Depending on the values of these parameters different optimum CP lengths are obtained. For a system using only one value of CP length we suggest an optimum value to be 4us...... for an OFDM symbol length of 40us and 6us for an OFDM symbol length of 80us....

  19. Tree Diamter Effects on Cost and Productivity of Cut-to-Length Systems

    Science.gov (United States)

    Matthew A. Holtzscher; Bobby L. Lanford

    1997-01-01

    Currently, there is a lack of economic information concerning cut-to-length harvesting systems. This study examined and measured the different costs of operating cut-to-length logging equipment over a range of average stand diameters at breast height. Three different cut-to-length logging systems were examined in this study. Systems included: 1) felier-buncher/manual/...

  20. Precise NMR measurement and stabilization system of magnetic field of a superconducting 7 T wave length shifter

    CERN Document Server

    Borovikov, V M; Karpov, G V; Korshunov, D A; Kuper, E A; Kuzin, M V; Mamkin, V R; Medvedko, A S; Mezentsev, N A; Repkov, V V; Shkaruba, V A; Shubin, E I; Veremeenko, V F

    2001-01-01

    The system of measurement and stabilization of the magnetic field in the superconducting 7 T wave length shifter (WLS), designed at Budker Institute of Nuclear Physics are described. The measurements are performed by nuclear magnetic resonance (NMR) magnetometer at two points of the WLS magnetic field. Stabilization of the field is provided by the current pumping system. The stabilization system is based on precise NMR measurement of magnetic field as a feedback signal for computer code which control currents inside the superconducting coils. The problem of the magnetic field measurements with NMR method consists in wide spread of field in the measured area (up to 50 Gs/mm), wide temperature range of WLS operating, small space for probe and influence of iron hysteresis. Special solid-state probes were designed to satisfy this requirements. The accuracy of magnetic field measurements at probe locations is not worse than 20 ppm. For the WLS field of 7 T the reproducibility of the magnetic field of 30 ppm has be...

  1. The accuracy of the radiographic method in root canal length measurement

    International Nuclear Information System (INIS)

    Jo, Eun Young; Park, Chang Seo

    1998-01-01

    For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems (p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems (p>0.05). 2. In Digora system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques (p 0.05). In conclusion, the determination of the root canal length by using the

  2. Development of a scanning tunneling potentiometry system for measurement of electronic transport at short length scales

    Science.gov (United States)

    Rozler, Michael

    It is clear that complete understanding of macroscopic properties of materials is impossible without a thorough knowledge of behavior at the smallest length scales. While the past 25 years have witnessed major advances in a variety of techniques that probe the nanoscale properties of matter, electrical transport measurements -- the heart of condensed matter research -- have lagged behind, never progressing beyond bulk measurements. This thesis describes a scanning tunneling potentiometry (STP) system developed to simultaneously map the transport-related electrochemical potential distribution of a biased sample along with its surface topography, extending electronic transport measurements to the nanoscale. Combining a novel sample biasing technique with a continuous current-nulling feedback scheme pushes the noise performance of the measurement to its fundamental limit - the Johnson noise of the STM tunnel junction. The resulting 130 nV voltage sensitivity allows us to spatially resolve local potentials at scales down to 2 nm, while maintaining atomic scale STM imaging, all at scan sizes of up to 15 microns. A mm-range two-dimensional coarse positioning stage and the ability to operate from liquid helium to room temperature with a fast turn-around time greatly expand the versatility of the instrument. Use of carefully selected model materials, combined with excellent topographic and voltage resolution has allowed us to distinguish measurement artifacts caused by surface roughness from true potentiometric features, a major problem in previous STP measurements. The measurements demonstrate that STP can produce physically meaningful results for homogeneous transport as well as non-uniform conduction dominated by material microstructures. Measurements of several physically interesting materials systems are presented as well, revealing new behaviors at the smallest length sales. The results establish scanning tunneling potentiometry as a useful tool for physics and

  3. Bunch Length Measurements in SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, W.J.; Fisher, A.; Huang, X.; Safranek, J.; Sebek, J.; /SLAC; Lumpkin, A.; /Argonne; Sannibale, F.; /LBL, Berkeley; Mok, W.; /Unlisted

    2007-11-28

    A series of bunch length measurements were made in SPEAR3 for two different machine optics. In the achromatic optics the bunch length increases from the low-current value of 16.6ps rms to about 30ps at 25ma/bunch yielding an inductive impedance of -0.17{Omega}. Reducing the momentum compaction factor by a factor of {approx}60 [1] yields a low-current bunch length of {approx}4ps rms. In this paper we review the experimental setup and results.

  4. Stride length: measuring its instantaneous value

    International Nuclear Information System (INIS)

    Campiglio, G C; Mazzeo, J R

    2007-01-01

    Human gait has been studied from different viewpoints: kinematics, dynamics, sensibility and others. Many of its characteristics still remain open to research, both for normal gait and for pathological gait. Objective measures of some of its most significant spatial/temporal parameters are important in this context. Stride length, one of these parameters, is defined as the distance between two consecutive contacts of one foot with ground. On this work we present a device designed to provide automatic measures of stride length. Its features make it particularly appropriate for the evaluation of pathological gait

  5. Minimal Length, Measurability and Gravity

    Directory of Open Access Journals (Sweden)

    Alexander Shalyt-Margolin

    2016-03-01

    Full Text Available The present work is a continuation of the previous papers written by the author on the subject. In terms of the measurability (or measurable quantities notion introduced in a minimal length theory, first the consideration is given to a quantum theory in the momentum representation. The same terms are used to consider the Markov gravity model that here illustrates the general approach to studies of gravity in terms of measurable quantities.

  6. Assessment of colorectal length using the electromagnetic capsule tracking system

    DEFF Research Database (Denmark)

    Mark, E B; Poulsen, J L; Haase, A M

    2017-01-01

    AIM: We aimed to determine colorectal length with the 3D-Transit system by describing a 'centerline' of capsule movement and compare it to known anatomy, as determined by magnetic resonance imaging (MRI). Further, we aimed to test the day-to-day variation of colorectal length assessed......: Computation of colorectal length from capsule passage was possible in 60 of the 67 3D-Transit recordings. Length of the colorectum measured with MRI and 3D-Transit was respectively 95 cm (75-153 cm) and 99 cm (77-147 cm), P = 0.15. Coefficient of variation (CV) between MRI and 3D-Transit was 7.8%. Apart from...... the cecum / ascending colon being 26% (P = 0.002) shorter on MRI, there were no other differences in total or segmental colorectal lengths between methods (all P > 0.05). Length of the colorectum measured with 3D-Transit on two consecutive days was 102 cm (73-119 cm) and 103 cm (75-123 cm), P = 0.67. CV...

  7. From Concrete to Abstract in the Measurement of Length

    International Nuclear Information System (INIS)

    Stephanou, Andreas; Fisher, William P Jr

    2013-01-01

    The concatenation of units of length is widely viewed as the paradigmatic expression of fundamental measurement. Survey, assessment, and test scores in educational and psychological measurement are often interpreted in ways that assume a concatenation of units to have been established, even though these assumptions are rarely stated or tested. A concatenation model for measurement is shown to be equivalent to a Rasch model: any two units of measurement placed end to end must together be of the same length as either one of them added to itself. This additive principle and a concatenation model of measurement together serve as a heuristic guide for organizing two experimental approaches to calibrating instruments for measuring length. The capacity to reproduce the unit of measurement from theory with no need for repeated empirical calibration experiments, as in the geometrical bisection of the line and the resultant halving of the length measure, is highlighted as essential to demonstrating a thorough understanding of the construct

  8. Validity of plant fiber length measurement : a review of fiber length measurement based on kenaf as a model

    Science.gov (United States)

    James S. Han; Theodore. Mianowski; Yi-yu. Lin

    1999-01-01

    The efficacy of fiber length measurement techniques such as digitizing, the Kajaani procedure, and NIH Image are compared in order to determine the optimal tool. Kenaf bast fibers, aspen, and red pine fibers were collected from different anatomical parts, and the fiber lengths were compared using various analytical tools. A statistical analysis on the validity of the...

  9. Diameter sensors for tree-length harvesting systems

    Science.gov (United States)

    T.P. McDonald; Robert B. Rummer; T.E. Grift

    2003-01-01

    Most cut-to-length (CTL) harvesters provide sensors for measuring diameter of trees as they are cut and processed. Among other uses, this capability provides a data collection tool for marketing of logs in real time. Logs can be sorted and stacked based on up-to-date market information, then transportation systems optimized to route wood to proper destinations at...

  10. Spherical aberration compensation method for long focal-length measurement based on Talbot interferometry

    Science.gov (United States)

    Luo, Yupeng; Huang, Xiao; Bai, Jian; Du, Juan; Liu, Qun; Luo, Yujie; Luo, Jia

    2017-08-01

    Large-aperture and long focal-length lens is widely used in high energy laser system. The method based on Talbot interferometry is a reliable method to measure the focal length of such elements. By employing divergent beam and two gratings of different periods, this method could realize full-aperture measurement, higher accuracy and better repeatability. However, it does not take into account the spherical aberration of the measured lens resulting in the moiré fringes bending, which will introduce measurement error. Furthermore, in long-focal measurement with divergent beam, this error is an important factor affecting the measurement accuracy. In this paper, we propose a new spherical aberration compensation method, which could significantly reduce the measurement error. Characterized by central-symmetric scanning window, the proposed method is based on the relationship between spherical aberration and the lens aperture. Angle data of moiré fringes in each scanning window is retrieved by Fourier analysis and statistically fitted to estimate a globally optimum value for spherical-aberration-free focal length calculation. Simulation and experiment have been carried out. Compared to the previous work, the proposed method is able to reduce the relative measurement error by 50%. The effect of scanning window size and shift step length on the results is also discussed.

  11. Tyre contact length on dry and wet road surfaces measured by three-axial accelerometer

    Science.gov (United States)

    Matilainen, Mika; Tuononen, Ari

    2015-02-01

    We determined the tyre contact length on dry and wet roads by measuring the accelerations of the inner liner with a three-axial accelerometer. The influence of the tyre pressure, driving velocity, and tread depth on the contact length was studied in both types of road surface conditions. On dry asphalt the contact length was almost constant, regardless of the driving velocity. On wet asphalt the presence of water could be detected even at low driving velocities (e.g. 20 km/h for a worn tyre) as the contact length began to decrease from that found in the dry asphalt situation. In addition to improving the performance of active safety systems and driver warning systems, the contact length information could be beneficial for classifying and studying the aquaplaning behaviour of tyres.

  12. Sonographic Measurement of Normal Splenic Length in Korean Adults

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sang Bum; Cheon, Byung Kook; Kim, Jong Min; Oh, Kyung Seoung; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk [Kosin University College of Medicine, Busan (Korea, Republic of)

    1996-12-15

    To establish upper limit of normal splenic length of Korean adults on ultrasonography and to determice the degree of interobserver and intraobserver variation. Ultrasonographic scans were performed to measure the maximum length of spleen in 105 of 150 adults selected by convenience sampling. Remained 45 cases with any conditions that could alter splenic size were excluded from this study. The maximum length of spleen was measured and correlated with body surface area, patient height, weight, age and sex. In 31 of the 105 adults we evaluated the interobserver and intraobserver variations in sonographic measurements of splenic length obtained by three radiologists in blind fashion. The mean splenic length in 105 adults was 8.56cm ({+-} 0.95). The splenic length positively correlated with body surface area, patient height and weight (P <0.001), and negatively correlated with patient age (P < 0.01). Male spleen (8.87 cm {+-} 1.07) was longer than female spleen (8.35 cm {+-} 0.81) (P < 0.05). The following guidelines are proposed for the upper limit of normal splenic length at different groups of body surface area: no longer than 10 cm at 1.20{approx}1.59 m{sup 2}, 11 cm at1.60{approx}1.79 m{sup 2}, and 12 cm at 1.80{approx}1.99 m{sup 2}. The mean interobserver variation between any two radiologists ranged from 0.32 cm ({+-} 0.29) to 0.39 cm ({+-} 0.33) and interobserver variations were within 1 cm in 96%. The mean intraobserver variations were within 0.5 cm in 91%. The splenic length closely correlated with body surface area, patient height, weight and age. Particularly the upper limit of normal splenic length changed according to body surface area. Interobserver variation about 1 cm and intraobserver variation about 0.5 cm should be considered in the measurement of the splenic length on ultrasonography

  13. Interobserver Variation of the Renal Length Measurement on Ultrasonography

    International Nuclear Information System (INIS)

    Jeong, Yoong Ki; Chung, Hye Weon; Kim, Tae Sung; Ryoo, Jae Wook; Kim, Tae Kyoung; Kim, Seung Hyup

    1995-01-01

    We assessed interobserver variation in the measurement of the renal length on ultrasonography. Ultrasonographic examinations were performed in randomly selected 50 patients. The maximallenhths of both kidneys were measured with calipers during the scanning from frozen images by three observers in a blinded fashion. There was a relatively constant tendency of an observer to measure a renal length either longer or shorter than the other observer(Kendall coefficient>0.05). Average interobserver variations were 0.51 cm (±0.42 cm) in right kidney and 0.53 cm (±0.41 cm) in left kidney and were within 1 cm in 91% right and 89% of left kidney. Interobserver variation about 1cm should be considered in the measurement of the renal length on ultrasonography

  14. Sonographic Measurement of Fetal Ear Length in Turkish Women with a Normal Pregnancy

    Directory of Open Access Journals (Sweden)

    Mucize Eriç Özdemir

    2014-12-01

    Full Text Available Background: Abnormal fetal ear length is a feature of chromosomal disorders. Fetal ear length measurement is a simple measurement that can be obtained during ultrasonographic examinations. Aims: To develop a nomogram for fetal ear length measurements in our population and investigate the correlation between fetal ear length, gestational age, and other standard fetal biometric measurements. Study Design: Cohort study. Methods: Ear lengths of the fetuses were measured in normal singleton pregnancies. The relationship between gestational age and fetal ear length in millimetres was analysed by simple linear regression. In addition, the correlation of fetal ear length measurements with biparietal diameter, head circumference, abdominal circumference, and femur length were evaluated.Ear length measurements were obtained from fetuses in 389 normal singleton pregnancies ranging between 16 and 28 weeks of gestation. Results: A nomogram was developed by linear regression analysis of the parameters ear length and gestational age. Fetal ear length (mm = y = (1.348 X gestational age-12.265, where gestational ages is in weeks. A high correlation was found between fetal ear length and gestational age, and a significant correlation was also found between fetal ear length and the biparietal diameter (r=0.962; p<0.001. Similar correlations were found between fetal ear length and head circumference, and fetal ear length and femur length. Conclusion: The results of this study provide a nomogram for fetal ear length. The study also demonstrates the relationship between ear length and other biometric measurements.

  15. Bunch Length Measurements using Coherent Radiation

    CERN Document Server

    Ischebeck, Rasmus; Barnes, Christopher; Blumenfeld, Ian; Clayton, Chris; Decker, Franz Josef; Deng, Suzhi; Hogan, Mark; Huang Cheng Kun; Iverson, Richard; Johnson, Devon K; Krejcik, Patrick; Lu, Wei; Marsh, Kenneth; Oz, Erdem; Siemann, Robert; Walz, Dieter

    2005-01-01

    The accelerating field that can be obtained in a beam-driven plasma wakefield accelerator depends on the current of the electron beam that excites the wake. In the E-167 experiment, a peak current above 10kA will be delivered at a particle energy of 28GeV. The bunch has a length of a few ten micrometers and several methods are used to measure its longitudinal profile. Among these, autocorrelation of coherent transition radiation (CTR) is employed. The beam passes a thin metallic foil, where it emits transition radiation. For wavelengths greater than the bunch length, this transition radiation is emitted coherently. This amplifies the long-wavelength part of the spectrum. A scanning Michelson interferometer is used to autocorrelate the CTR. However, this method requires the contribution of many bunches to build an autocorrelation trace. The measurement is influenced by the transmission characteristics of the vacuum window and beam splitter. We present here an analysis of materials, as well as possible layouts ...

  16. Measuring minority-carrier diffusion length using a Kelvin probe force microscope

    International Nuclear Information System (INIS)

    Shikler, R.; Fried, N.; Meoded, T.; Rosenwaks, Y.

    2000-01-01

    A method based on Kelvin probe force microscopy for measuring minority-carrier diffusion length in semiconductors is described. The method is based on measuring the surface photovoltage between the tip of an atomic force microscope and the surface of an illuminated semiconductor junction. The photogenerated carriers diffuse to the junction and change the contact potential difference between the tip and the sample, as a function of the distance from the junction. The diffusion length L is then obtained by fitting the measured contact potential difference using the minority-carrier continuity equation. The method was applied to measurements of electron diffusion length in GaP pn and Schottky junctions. The measured diffusion length was found to be ∼2 μm, in good agreement with electron beam induced current measurements

  17. Coupling of relative intensity noise and pathlength noise to the length measurement in the optical metrology system of LISA Pathfinder

    Science.gov (United States)

    Wittchen, Andreas; the LPF Collaboration

    2017-05-01

    LISA Pathfinder is a technology demonstration mission for the space-based gravitational wave observatory, LISA. It demonstrated that the performance requirements for the interferometric measurement of two test masses in free fall can be met. An important part of the data analysis is to identify the limiting noise sources. [1] This measurement is performed with heterodyne interferometry. The performance of this optical metrology system (OMS) at high frequencies is limited by sensing noise. One such noise source is Relative Intensity Noise (RIN). RIN is a property of the laser, and the photodiode current generated by the interferometer signal contains frequency dependant RIN. From this electric signal the phasemeter calculates the phase change and laser power, and the coupling of RIN into the measurement signal depends on the noise frequency. RIN at DC, at the heterodyne frequency and at two times the heterodyne frequency couples into the phase. Another important noise at high frequencies is path length noise. To reduce the impact this noise is suppressed with a control loop. Path length noise not suppressed will couple directly into the length measurement. The subtraction techniques of both noise sources depend on the phase difference between the reference signal and the measurement signal, and thus on the test mass position. During normal operations we position the test mass at the interferometric zero, which is optimal for noise subtraction purposes. This paper will show results from an in-flight experiment where the test mass position was changed to make the position dependant noise visible.

  18. The reliability of transabdominal cervical length measurement in a low-risk obstetric population: Comparison with transvaginal measurement.

    Science.gov (United States)

    Peng, Cheng-Ran; Chen, Chie-Pein; Wang, Kuo-Gon; Wang, Liang-Kai; Chen, Chen-Yu; Chen, Yi-Yung

    2015-04-01

    To determine the correlation between transabdominal (TA) and transvaginal (TV) cervical length measurement in a low-risk obstetric population in Taiwan. Women with a singleton pregnancy between 20 weeks and 24 weeks of gestation underwent postvoid TA and TV cervical length measurements. Differences between the measurements obtained using the two methods were evaluated. Two hundred and five women agreed to participate in the study. Paired TA and TV measurements were obtained in 174 women. The mean TA cervical length was 36.0 ± 4.9 mm and the mean TV cervical length was 37.6 ± 5.4 mm. The mean TA cervical length was shorter than the mean TV cervical length by 1.6 mm. The 5(th) percentile of TA and TV cervical length was 29 mm and 29.1 mm, respectively. The discrepancies between the two methods were not significantly correlated with maternal body mass index (BMI). All women with TV cervical length women in the present study, and the TA cervical length was closely correlated with the TV cervical length. The use of TA ultrasound could be an effective initial tool for cervical length screening in low-risk pregnant women. TA cervical length TV ultrasound. Copyright © 2015. Published by Elsevier B.V.

  19. Study on dynamic measurement of fuel pellet length during loading into cladding tube

    International Nuclear Information System (INIS)

    Zhang Kai

    1993-09-01

    Various methods are presented for measuring the pellet length in the cladding tube (zirconium tube) during the loading process of the preparation of single rod of nuclear fuel assembly. These methods are used in former Soviet Union, west European countries and China in the manufacturing of nuclear power plant element. Different methods of dynamic measurement by using mechanics, optics and electricity and their special features are analysed and discussed. The structure and measuring principle of a developed measuring device,and its measuring precision and system deviation are also introduced. Finally, the length of loaded pellets is checked with analog pellets. The results are as expected and show that the method and principle used in the measuring device are feasible. It is an ideal and advanced method for the pellet loading of single cladding tube. The principle mentioned above can also be used in other industries

  20. Cervical length measurement: comparison of transabdominal and transvaginal approach

    DEFF Research Database (Denmark)

    Westerway, Sue C; Pedersen, Lars Henning; Hyett, Jon

    2015-01-01

    to external cervical os. Bland- Altman plots and Wilcoxon signed rank test were used to evaluate differences between TA and TV measurements. Results: The validity of the TA method depended on cervical length. Although the TA method underestimated cervical length by 2.0 mm on average (P ... plots showed an inverse trend with shorter cervixes. In women with a cervix test to detect cervical length

  1. [Shushu (ancient Chinese numerology) in Lingshu: Gudu (Miraculous Pivot: Bone-Length Measurement)].

    Science.gov (United States)

    Zhuo, Lian-Shi

    2010-10-01

    Lingshu: Gudu (Miraculous Pivot: Bone-Length Measurement) is compared with literatures concerning the Shushu (ancient Chinese numerology) of the Qin Dynasty (221 B. C. - 206 B. C. ) and the Han Dynasty (206 B. C.-220 A. D.) in this article. And it is discovered that "the number of heaven and earth" in Yijing (The Book of Change) was implied in the bone-length measurement. The theory of Shushu is hidden in the sized of head, neck, chest, abdomen, back and 4 extremities according to the measurement. The meaning of establishment of bone-length measurement, which is found to have universality, laid in setting down the measurement of meridians. And it is the origin of the proportional measurement of locating acupoints. Checked with the theory of Shushu, errors in the description of bone-length measurement could also be found in Lingshu: Gudu (Miraculous Pivot: Bone-Length Measurement) of the present edition, which is helpful for the modern study on the measurement.

  2. Young Children's Understandings of Length Measurement: Evaluating a Learning Trajectory

    Science.gov (United States)

    Szilagyi, Janka; Clements, Douglas H.; Sarama, Julie

    2013-01-01

    This study investigated the development of length measurement ideas in students from prekindergarten through 2nd grade. The main purpose was to evaluate and elaborate the developmental progression, or levels of thinking, of a hypothesized learning trajectory for length measurement to ensure that the sequence of levels of thinking is consistent…

  3. In vivo myograph measurement of muscle contraction at optimal length

    Directory of Open Access Journals (Sweden)

    Ahmed Aminul

    2007-01-01

    Full Text Available Abstract Background Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. Methods We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. Results In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. Conclusion We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

  4. Statistical length of DNA based on AFM image measured by a computer

    International Nuclear Information System (INIS)

    Chen Xinqing; Qiu Xijun; Zhang Yi; Hu Jun; Wu Shiying; Huang Yibo; Ai Xiaobai; Li Minqian

    2001-01-01

    Taking advantage of image processing technology, the contour length of DNA molecule was measured automatically by a computer. Based on the AFM image of DNA, the topography of DNA was simulated into a curve. Then the DNA length was measured automatically by inserting mode. It was shown that the experimental length of a naturally deposited DNA (180.4 +- 16.4 nm) was well consistent with the theoretical length (185.0 nm). Comparing to other methods, the present approach had advantages of precision and automatism. The stretched DNA was also measured. It present approach had advantages of precision and automatism. The stretched DNA was also measured. It was shown that the experimental length (343.6 +- 20.7 nm) was much longer than the theoretical length (307.0 nm). This result indicated that the stretching process had a distinct effect on the DNA length. However, the method provided here avoided the DNA-stretching effect

  5. Measurement of clavicular length and shortening after a midshaft clavicular fracture: Spatial digitization versus planar roentgen photogrammetry.

    Science.gov (United States)

    Stegeman, Sylvia A; de Witte, Pieter Bas; Boonstra, Sjoerd; de Groot, Jurriaan H; Nagels, Jochem; Krijnen, Pieta; Schipper, Inger B

    2016-08-01

    Clavicular shortening after fracture is deemed prognostic for clinical outcome and is therefore generally assessed on radiographs. It is used for clinical decision making regarding operative or non-operative treatment in the first 2weeks after trauma, although the reliability and accuracy of the measurements are unclear. This study aimed to assess the reliability of roentgen photogrammetry (2D) of clavicular length and shortening, and to compare these with 3D-spatial digitization measurements, obtained with an electromagnetic recording system (Flock of Birds). Thirty-two participants with a consolidated non-operatively treated two or multi-fragmented dislocated midshaft clavicular fracture were analysed. Two observers measured clavicular lengths and absolute and proportional clavicular shortening on radiographs taken before and after fracture consolidation. The clavicular lengths were also measured with spatial digitization. Inter-observer agreement on the radiographic measurements was assessed using the Intraclass Correlation Coefficient (ICC). Agreement between the radiographic and spatial digitization measurements was assessed using a Bland-Altman plot. The inter-observer agreement on clavicular length, and absolute and proportional shortening on trauma radiographs was almost perfect (ICC>0.90), but moderate for absolute shortening after consolidation (ICC=0.45). The Bland-Altman plot compared measurements of length on AP panorama radiographs with spatial digitization and showed that planar roentgen photogrammetry resulted in up to 37mm longer and 34mm shorter measurements than spatial digitization. Measurements of clavicular length on radiographs are highly reliable between observers, but may not reflect the actual length and shortening of the clavicle when compared to length measurements with spatial digitization. We recommend to use proportional shortening when measuring clavicular length or shortening on radiographs for clinical decision making. Copyright

  6. Effective Debye length in closed nanoscopic systems: a competition between two length scales.

    Science.gov (United States)

    Tessier, Frédéric; Slater, Gary W

    2006-02-01

    The Poisson-Boltzmann equation (PBE) is widely employed in fields where the thermal motion of free ions is relevant, in particular in situations involving electrolytes in the vicinity of charged surfaces. The applications of this non-linear differential equation usually concern open systems (in osmotic equilibrium with an electrolyte reservoir, a semi-grand canonical ensemble), while solutions for closed systems (where the number of ions is fixed, a canonical ensemble) are either not appropriately distinguished from the former or are dismissed as a numerical calculation exercise. We consider herein the PBE for a confined, symmetric, univalent electrolyte and quantify how, in addition to the Debye length, its solution also depends on a second length scale, which embodies the contribution of ions by the surface (which may be significant in high surface-to-volume ratio micro- or nanofluidic capillaries). We thus establish that there are four distinct regimes for such systems, corresponding to the limits of the two parameters. We also show how the PBE in this case can be formulated in a familiar way by simply replacing the traditional Debye length by an effective Debye length, the value of which is obtained numerically from conservation conditions. But we also show that a simple expression for the value of the effective Debye length, obtained within a crude approximation, remains accurate even as the system size is reduced to nanoscopic dimensions, and well beyond the validity range typically associated with the solution of the PBE.

  7. Microdose acquisition in adolescent leg length discrepancy using a low-dose biplane imaging system.

    Science.gov (United States)

    Jensen, Janni; Mussmann, Bo R; Hjarbæk, John; Al-Aubaidi, Zaid; Pedersen, Niels W; Gerke, Oke; Torfing, Trine

    2017-09-01

    Background Children with leg length discrepancy often undergo repeat imaging. Therefore, every effort to reduce radiation dose is important. Using low dose preview images and noise reduction software rather than diagnostic images for length measurements might contribute to reducing dose. Purpose To compare leg length measurements performed on diagnostic images and low dose preview images both acquired using a low-dose bi-planar imaging system. Material and Methods Preview and diagnostic images from 22 patients were retrospectively collected (14 girls, 8 boys; mean age, 12.8 years; age range, 10-15 years). All images were anonymized and measured independently by two musculoskeletal radiologists. Three sets of measurements were performed on all images; the mechanical axis lines of the femur and the tibia as well as the anatomical line of the entire extremity. Statistical significance was tested with a paired t-test. Results No statistically significant difference was found between measurements performed on the preview and on the diagnostic image. The mean tibial length difference between the observers was -0.06 cm (95% confidence interval [CI], -0.12 to 0.01) and -0.08 cm (95% CI, -0.21 to 0.05), respectively; 0.10 cm (95% CI, 0.02-0.17) and 0.06 cm (95% CI, -0.02 to 0.14) for the femoral measurements and 0.12 cm (95% CI, -0.05 to 0.26) and 0.08 cm (95% CI, -0.02 to 0.19) for total leg length discrepancy. ICCs were >0.99 indicating excellent inter- and intra-rater reliability. Conclusion The data strongly imply that leg length measurements performed on preview images from a low-dose bi-planar imaging system are comparable to measurements performed on diagnostic images.

  8. Measurement of Debye length in laser-produced plasma.

    Science.gov (United States)

    Ehler, W.

    1973-01-01

    The Debye length of an expanded plasma created by placing an evacuated chamber with an entrance slit in the path of a freely expanding laser produced plasma was measured, using the slab geometry. An independent measurement of electron density together with the observed value for the Debye length also provided a means for evaluating the plasma electron temperature. This temperature has applications in ascertaining plasma conductivity and magnetic field necessary for confinement of the laser produced plasma. Also, the temperature obtained would be useful in analyzing electron-ion recombination rates in the expanded plasma and the dynamics of the cooling process of the plasma expansion.

  9. Utility of telomere length measurements for age determination of humpback whales

    Directory of Open Access Journals (Sweden)

    Morten Tange Olsen

    2014-12-01

    Full Text Available This study examines the applicability of telomere length measurements by quantitative PCR as a tool for minimally invasive age determination of free-ranging cetaceans. We analysed telomere length in skin samples from 28 North Atlantic humpback whales (Megaptera novaeangliae, ranging from 0 to 26 years of age. The results suggested a significant correlation between telomere length and age in humpback whales. However, telomere length was highly variable among individuals of similar age, suggesting that telomere length measured by quantitative PCR is an imprecise determinant of age in humpback whales. The observed variation in individual telomere length was found to be a function of both experimental and biological variability, with the latter perhaps reflecting patterns of inheritance, resource allocation trade-offs, and stochasticity of the marine environment.

  10. Radial correlation length measurements on ASDEX Upgrade using correlation Doppler reflectometry

    International Nuclear Information System (INIS)

    Schirmer, J; Conway, G D; Holzhauer, E; Suttrop, W; Zohm, H

    2007-01-01

    The technique of correlation Doppler reflectometry for providing radial correlation length L r measurements is explored in this paper. Experimental L r measurements are obtained using the recently installed dual channel Doppler reflectometer system on ASDEX Upgrade. The experimental measurements agree well with theory and with L r measured on other fusion devices using different diagnostic techniques. A strong link between L r and plasma confinement could be observed. From the L- to the H-mode, an increase in the absolute value of E r shear was detected at the same plasma edge region where a decrease in L r was measured. This observation is in agreement with theoretical models which predict that an increase in the absolute shear suppresses turbulent fluctuations in the plasma, leading to a reduction in L r . Furthermore, L r decreases from the plasma core to the edge and decreases with increasing plasma triangularity δ. The experimental results have been extensively modelled using a 2-dimensional finite difference time domain code. The simulations confirm that Doppler reflectometry provides robust radial correlation lengths of the turbulence with high resolution and suggests that L r is independent of the turbulence wavenumber k p erpendicular and its fluctuation level

  11. Utilization of coincidence criteria in absolute length measurements by optical interferometry in vacuum and air

    International Nuclear Information System (INIS)

    Schödel, R

    2015-01-01

    Traceability of length measurements to the international system of units (SI) can be realized by using optical interferometry making use of well-known frequencies of monochromatic light sources mentioned in the Mise en Pratique for the realization of the metre. At some national metrology institutes, such as Physikalisch-Technische Bundesanstalt (PTB) in Germany, the absolute length of prismatic bodies (e.g. gauge blocks) is realized by so-called gauge-block interference comparators. At PTB, a number of such imaging phase-stepping interference comparators exist, including specialized vacuum interference comparators, each equipped with three highly stabilized laser light sources. The length of a material measure is expressed as a multiple of each wavelength. The large number of integer interference orders can be extracted by the method of exact fractions in which the coincidence of the lengths resulting from the different wavelengths is utilized as a criterion. The unambiguous extraction of the integer interference orders is an essential prerequisite for correct length measurements. This paper critically discusses coincidence criteria and their validity for three modes of absolute length measurements: 1) measurements under vacuum in which the wavelengths can be identified with the vacuum wavelengths, 2) measurements under air in which the air refractive index is obtained from environmental parameters using an empirical equation, and 3) measurements under air in which the air refractive index is obtained interferometrically by utilizing a vacuum cell placed along the measurement pathway. For case 3), which corresponds to PTB’s Kösters-Comparator for long gauge blocks, the unambiguous determination of integer interference orders related to the air refractive index could be improved by about a factor of ten when an ‘overall dispersion value,’ suggested in this paper, is used as coincidence criterion. (paper)

  12. Spectral interferometric length measurement and tomography

    International Nuclear Information System (INIS)

    Pinkl, W.

    1998-01-01

    This work presents a new method for optical length measurement using the principles of spectral interferometry. Results of thickness measurements on glass plates, the human cornea in vivo and human finger and toe nails in vivo and in vitro are discussed. It could be demonstrated that the absorption coefficient of red and green ink can be measured depth sensitive. Another chapter describes a new technique to measure a thickness profile of a sample within the illuminating beam. It could be demonstrated that a thickness profile over a distance of a few millimeters can be measured with one single measurement. At the Institute of Medical Physics of the University of Vienna a method to measure intraocular distances by the means of interferometry has been developed during the last ten years. Basing on this method (dual beam interferometry) an optical in vivo tomography experiment could be established. A thickness map of the retina of a human eye in vivo can be easily measured. The dual beam technique uses a Michelson interferometer with a moving mirror to adjust the length of the interferometer arms. The mirror is moved by a stepper motor. This movement induces vibrations, misalignment and other disadvantages. So mechanically moved parts as reasons for possible errors should be eliminated. This work shows one possible solution - using the principle of spectral interferometry. A spectral interferometry experiment is a static experiment, no moving parts are used. A spectral interferometry experiment has been used to measure the thickness of glass plates and stacks of glass plates. Using two light sources of different wavelengths spectral absorption properties of a sample can be measured depth sensitive. This could be demonstrated with stacks of glass plates and the use of red and green ink between two plates. The obtained results are compared to the results of a computer simulation. To demonstrate the ability of spectral interferometry to measure the thickness of biologic

  13. A simple method for estimating the length density of convoluted tubular systems.

    Science.gov (United States)

    Ferraz de Carvalho, Cláudio A; de Campos Boldrini, Silvia; Nishimaru, Flávio; Liberti, Edson A

    2008-10-01

    We present a new method for estimating the length density (Lv) of convoluted tubular structures exhibiting an isotropic distribution. Although the traditional equation Lv=2Q/A is used, the parameter Q is obtained by considering the collective perimeters of tubular sections. This measurement is converted to a standard model of the structure, assuming that all cross-sections are approximately circular and have an average perimeter similar to that of actual circular cross-sections observed in the same material. The accuracy of this method was tested in eight experiments using hollow macaroni bent into helical shapes. After measuring the length of the macaroni segments, they were boiled and randomly packed into cylindrical volumes along with an aqueous suspension of gelatin and India ink. The solidified blocks were cut into slices 1.0 cm thick and 33.2 cm2 in area (A). The total perimeter of the macaroni cross-sections so revealed was stereologically estimated using a test system of straight parallel lines. Given Lv and the reference volume, the total length of macaroni in each section could be estimated. Additional corrections were made for the changes induced by boiling, and the off-axis position of the thread used to measure length. No statistical difference was observed between the corrected estimated values and the actual lengths. This technique is useful for estimating the length of capillaries, renal tubules, and seminiferous tubules.

  14. Foot length measurements of newborns of high and low risk pregnancies

    Directory of Open Access Journals (Sweden)

    Ana Karina Marques Salge

    Full Text Available Abstract OBJECTIVE Comparing foot length measurements of newborns in high and low risk pregnancies at a public hospital in Goiânia, GO, Brazil. METHOD A cross-sectional study carried out between April, 2013 and May, 2015, with a sample consisting of 180 newborns; 106 infants of women from high-risk pregnancies and 74 of women from low-risk pregnancies. Data were descriptively analyzed. Foot length measurement was performed using a stiff transparent plastic ruler, graduated in millimeters. The length of both feet was measured from the tip of the hallux (big toe to the end of the heel. RESULTS A statistically significant relationship was found between the foot length and newborn’s weight, between the cephalic and thoracic perimeters in the high-risk group and between the cephalic perimeter in the control group. CONCLUSION There is a need for creating cut-off points to identify newborns with intrauterine growth disorders using foot length.

  15. Slip length measurement of confined air flow on three smooth surfaces.

    Science.gov (United States)

    Pan, Yunlu; Bhushan, Bharat; Maali, Abdelhamid

    2013-04-02

    An experimental measurement of the slip length of air flow close to three different solid surfaces is presented. The substrate was driven by a nanopositioner moving toward an oscillating glass sphere glued to an atomic force microscopy (AFM) cantilever. A large separation distance was used to get more effective data. The slip length value was obtained by analyzing the amplitude and phase data of the cantilever. The measurements show that the slip length does not depend on the oscillation amplitude of the cantilever. Because of the small difference among the slip lengths of the three surfaces, a simplified analysis method was used. The results show that on glass, graphite, and mica surfaces the slip lengths are 98, 234, and 110 nm, respectively.

  16. MARBLE (Multiple Antenna Radio-interferometry for Baseline Length Evaluation): Development of a Compact VLBI System for Calibrating GNSS and Electronic Distance Measurement Devices

    Science.gov (United States)

    Ichikawa, R.; Ishii, A.; Takiguchi, H.; Kimura, M.; Sekido, M.; Takefuji, K.; Ujihara, H.; Hanado, Y.; Koyama, Y.; Kondo, T.; Kurihara, S.; Kokado, K.; Kawabata, R.; Nozawa, K.; Mukai, Y.; Kuroda, J.; Ishihara, M.; Matsuzaka, S.

    2012-12-01

    We are developing a compact VLBI system with a 1.6-m diameter aperture dish in order to provide reference baseline lengths for calibration. The reference baselines are used to validate surveying instruments such as GPS and EDM and is maintained by the Geospatial Information Authority of Japan (GSI). The compact VLBI system will be installed at both ends of the reference baseline. Since the system is not sensitive enough to detect fringes between the two small dishes, we have designed a new observation concept including one large dish station. We can detect two group delays between each compact VLBI system and the large dish station based on conventional VLBI measurement. A group delay between the two compact dishes can be indirectly calculated using a simple equation. We named the idea "Multiple Antenna Radio-interferometry for Baseline Length Evaluation", or MARBLE system. The compact VLBI system is easy transportable and consists of the compact dish, a new wide-band front-end system, azimuth and elevation drive units, an IF down-converter unit, an antenna control unit (ACU), a counterweight, and a monument pillar. Each drive unit is equipped with a zero-backlash harmonic drive gearing component. A monument pillar is designed to mount typical geodetic GNSS antennas easily and an offset between the GNSS antenna reference point. The location of the azimuth-elevation crossing point of the VLBI system is precisely determined with an uncertainty of less than 0.2 mm. We have carried out seven geodetic VLBI experiments on the Kashima-Tsukuba baseline (about 54 km) using the two prototypes of the compact VLBI system between December 2009 and December 2010. The average baseline length and repeatability of the experiments is 54184874.0 ± 2.4 mm. The results are well consistent with those obtained by GPS measurements. In addition, we are now planning to use the compact VLBI system for precise time and frequency comparison between separated locations.

  17. Normal standards for kidney length as measured with US in premature infants

    International Nuclear Information System (INIS)

    Schlesinger, A.E.; Hedlund, G.L.; Pierson, W.P.; Null, D.M.

    1986-01-01

    In order to develop normal standards for kidney length in premature infants, the authors measured kidney length by US imaging in 39 (to date) premature infants less than 72 hours old and without known renal disease. Kidney length was compared with four different parameters of body size, including gestational age, birth weight, birth length, and body surface area. Similar standards have been generated previously for normal renal length as measured by US imaging in full-term infants and older children. These standards have proven utility in cases of congenital and acquired disorders that abnormally increase or decrease renal size. Scatter plots of kidney length versus body weight and kidney length versus body surface area conformed well to a logarithmic distribution, with a high correlation coefficient and close-fitting 95% confidence limits (SEE = 2.05)

  18. Length-free near infrared measurement of newborn malnutrition

    Science.gov (United States)

    Mustafa, Fatin Hamimi; Bek, Emily J.; Huvanandana, Jacqueline; Jones, Peter W.; Carberry, Angela E.; Jeffery, Heather E.; Jin, Craig T.; McEwan, Alistair L.

    2016-11-01

    Under-nutrition in neonates can cause immediate mortality, impaired cognitive development and early onset adult disease. Body fat percentage measured using air-displacement-plethysmography has been found to better indicate under-nutrition than conventional birth weight percentiles. However, air-displacement-plethysmography equipment is expensive and non-portable, so is not suited for use in developing communities where the burden is often the greatest. We proposed a new body fat measurement technique using a length-free model with near-infrared spectroscopy measurements on a single site of the body - the thigh. To remove the need for length measurement, we developed a model with five discrete wavelengths and a sex parameter. The model was developed using air-displacement-plethysmography measurements in 52 neonates within 48 hours of birth. We identified instrumentation required in a low-cost LED-based screening device and incorporated a receptor device that can increase the amount of light collected. This near-infrared method may be suitable as a low cost screening tool for detecting body fat levels and monitoring nutritional interventions for malnutrition in neonates and young children in resource-constrained communities.

  19. Electron bunch length measurement with a wakefield radiation decelerator

    Directory of Open Access Journals (Sweden)

    Weiwei Li

    2014-03-01

    Full Text Available In this paper, we propose a novel method to measure the electron bunch length with a dielectric wakefield radiation (DWR decelerator which is composed of two dielectric-lined waveguides (DLWs and an electron spectrometer. When an electron beam passes through a DLW, the DWR is excited which leads to an energy loss of the electron beam. The energy loss is found to be largely dependent on the electron bunch length and can be easily measured by an electron spectrometer which is essential for a normal accelerator facility. Our study shows that this method has a high resolution and a great simplicity.

  20. Observers' measurements in premetric electrodynamics: Time and radar length

    Science.gov (United States)

    Gürlebeck, Norman; Pfeifer, Christian

    2018-04-01

    The description of an observer's measurement in general relativity and the standard model of particle physics is closely related to the spacetime metric. In order to understand and interpret measurements, which test the metric structure of the spacetime, like the classical Michelson-Morley, Ives-Stilwell, Kennedy-Thorndike experiments or frequency comparison experiments in general, it is necessary to describe them in theories, which go beyond the Lorentzian metric structure. However, this requires a description of an observer's measurement without relying on a metric. We provide such a description of an observer's measurement of the fundamental quantities time and length derived from a premetric perturbation of Maxwell's electrodynamics and a discussion on how these measurements influence classical relativistic observables like time dilation and length contraction. Most importantly, we find that the modification of electrodynamics influences the measurements at two instances: the propagation of light is altered as well as the observer's proper time normalization. When interpreting the results of a specific experiment, both effects cannot be disentangled, in general, and have to be taken into account.

  1. Automatic measurement of axial length of human eye using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Kiryu, Tohru

    2011-01-01

    The measurement of axial length and the evaluation of three dimensional (3D) form of an eye are essential to evaluate the mechanism of myopia progression. We propose a method of automatic measurement of axial length including adjustment of the pulse sequence of short-term scan which could suppress influence of eyeblink, using a magnetic resonance imaging (MRI) which acquires 3D images noninvasively. Acquiring T 2 -weighted images with 3.0 tesla MRI device and eight-channel phased-array head coil, we extracted left and right eye ball images, and then reconstructed 3D volume. The surface coordinates were calculated from 3D volume, fitting the ellipsoid model coordinates with the surface coordinates, and measured the axial length automatically. Measuring twenty one subjects, we compared the automatically measured values of axial length with the manually measured ones, then confirmed significant elongation in the axial length of myopia compared with that of emmetropia. Furthermore, there were no significant differences (P<0.05) between the means of automatic measurements and the manual ones. Accordingly, the automatic measurement process of axial length could be a tool for the elucidation of the mechanism of myopia progression, which would be suitable for evaluating the axial length easily and noninvasively. (author)

  2. Technique for the focal-length measurement of positive lenses using Fizeau interferometry

    International Nuclear Information System (INIS)

    Pavan Kumar, Yeddanapudi; Chatterjee, Sanjib

    2009-01-01

    We present what we believe is a new technique for the focal-length measurement of positive lenses using Fizeau interferometery. The technique utilizes the Gaussian lens equation. The image distance is measured interferometrically in terms of the radius of curvature of the image-forming wavefront emerging from the lens. The radii of curvature of the image-forming wavefronts corresponding to two different axial object positions of known separation are measured. The focal length of the lens is determined by solving the equations obtained using the Gaussian lens equation for the two object positions. Results obtained for a corrected doublet lens of a nominal focal length of 200.0 mm with a measurement uncertainty of ±2.5% is presented

  3. A radiographic method for measurement of leg length inequality.

    Science.gov (United States)

    Friberg, O; Koivisto, E; Wegelius, C

    1985-01-01

    An accurate and simple radiographic method for the measurement of weight-bearing leg length inequality with a minimum of radiated body area is described. The measurement can be made in a conventional chest X-ray unit without other extra equipment than a gonad shield described here.

  4. Low-power grating detection system chip for high-speed low-cost length and angle precision measurement

    Science.gov (United States)

    Hou, Ligang; Luo, Rengui; Wu, Wuchen

    2006-11-01

    This paper forwards a low power grating detection chip (EYAS) on length and angle precision measurement. Traditional grating detection method, such as resister chain divide or phase locked divide circuit are difficult to design and tune. The need of an additional CPU for control and display makes these methods' implementation more complex and costly. Traditional methods also suffer low sampling speed for the complex divide circuit scheme and CPU software compensation. EYAS is an application specific integrated circuit (ASIC). It integrates micro controller unit (MCU), power management unit (PMU), LCD controller, Keyboard interface, grating detection unit and other peripherals. Working at 10MHz, EYAS can afford 5MHz internal sampling rate and can handle 1.25MHz orthogonal signal from grating sensor. With a simple control interface by keyboard, sensor parameter, data processing and system working mode can be configured. Two LCD controllers can adapt to dot array LCD or segment bit LCD, which comprised output interface. PMU alters system between working and standby mode by clock gating technique to save power. EYAS in test mode (system action are more frequently than real world use) consumes 0.9mw, while 0.2mw in real world use. EYAS achieved the whole grating detection system function, high-speed orthogonal signal handling in a single chip with very low power consumption.

  5. Measuring digit lengths with 3D digital stereophotogrammetry: A comparison across methods.

    Science.gov (United States)

    Gremba, Allison; Weinberg, Seth M

    2018-05-09

    We compared digital 3D stereophotogrammetry to more traditional measurement methods (direct anthropometry and 2D scanning) to capture digit lengths and ratios. The length of the second and fourth digits was measured by each method and the second-to-fourth ratio was calculated. For each digit measurement, intraobserver agreement was calculated for each of the three collection methods. Further, measurements from the three methods were compared directly to one another. Agreement statistics included the intraclass correlation coefficient (ICC) and technical error of measurement (TEM). Intraobserver agreement statistics for the digit length measurements were high for all three methods; ICC values exceeded 0.97 and TEM values were below 1 mm. For digit ratio, intraobserver agreement was also acceptable for all methods, with direct anthropometry exhibiting lower agreement (ICC = 0.87) compared to indirect methods. For the comparison across methods, the overall agreement was high for digit length measurements (ICC values ranging from 0.93 to 0.98; TEM values below 2 mm). For digit ratios, high agreement was observed between the two indirect methods (ICC = 0.93), whereas indirect methods showed lower agreement when compared to direct anthropometry (ICC < 0.75). Digit measurements and derived ratios from 3D stereophotogrammetry showed high intraobserver agreement (similar to more traditional methods) suggesting that landmarks could be placed reliably on 3D hand surface images. While digit length measurements were found to be comparable across all three methods, ratios derived from direct anthropometry tended to be higher than those calculated indirectly from 2D or 3D images. © 2018 Wiley Periodicals, Inc.

  6. Design and construction of an optical test bed for LISA imaging systems and tilt-to-length coupling

    International Nuclear Information System (INIS)

    Chwalla, M; Fitzsimons, E; Danzmann, K; Fernández Barranco, G; Gerberding, O; Heinzel, G; Lieser, M; Schuster, S; Schwarze, T S; Tröbs, M; Zwetz, M; Killow, C J; Perreur-Lloyd, M; Robertson, D I; Ward, H

    2016-01-01

    The laser interferometer space antenna (LISA) is a future space-based interferometric gravitational-wave detector consisting of three spacecraft in a triangular configuration. The interferometric measurements of path length changes between satellites will be performed on optical benches in the satellites. Angular misalignments of the interfering beams couple into the length measurement and represent a significant noise source. Imaging systems will be used to reduce this tilt-to-length coupling. We designed and constructed an optical test bed to experimentally investigate tilt-to-length coupling. It consists of two separate structures, a minimal optical bench and a telescope simulator. The minimal optical bench comprises the science interferometer where the local laser is interfered with light from a remote spacecraft. In our experiment, a simulated version of this received beam is generated on the telescope simulator. The telescope simulator provides a tilting beam, a reference interferometer and an additional static beam as a phase reference. The tilting beam can either be a flat-top beam or a Gaussian beam. We avoid tilt-to-length coupling in the reference interferometer by using a small photo diode placed at an image of the beam rotation point. We show that the test bed is operational with an initial measurement of tilt-to-length coupling without imaging systems. Furthermore, we show the design of two different imaging systems whose performance will be investigated in future experiments. (paper)

  7. Influence of Landscape Coverage on Measuring Spatial and Length Properties of Rock Fracture Networks: Insights from Numerical Simulation

    Science.gov (United States)

    Cao, Wenzhuo; Lei, Qinghua

    2018-01-01

    Natural fractures are ubiquitous in the Earth's crust and often deeply buried in the subsurface. Due to the difficulty in accessing to their three-dimensional structures, the study of fracture network geometry is usually achieved by sampling two-dimensional (2D) exposures at the Earth's surface through outcrop mapping or aerial photograph techniques. However, the measurement results can be considerably affected by the coverage of forests and other plant species over the exposed fracture patterns. We quantitatively study such effects using numerical simulation. We consider the scenario of nominally isotropic natural fracture systems and represent them using 2D discrete fracture network models governed by fractal and length scaling parameters. The groundcover is modelled as random patches superimposing onto the 2D fracture patterns. The effects of localisation and total coverage of landscape patches are further investigated. The fractal dimension and length exponent of the covered fracture networks are measured and compared with those of the original non-covered patterns. The results show that the measured length exponent increases with the reduced localisation and increased coverage of landscape patches, which is more evident for networks dominated by very large fractures (i.e. small underlying length exponent). However, the landscape coverage seems to have a minor impact on the fractal dimension measurement. The research findings of this paper have important implications for field survey and statistical analysis of geological systems.

  8. The accuracy of axial length measurements in cases of macula-off retinal detachment.

    Science.gov (United States)

    Abou-Shousha, Mohsen; Helaly, Hany Ahmed; Osman, Ihab Mohamed

    2016-04-01

    To assess the accuracy of axial length measurements in cases of macula-off retinal detachment using different methods (optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry). This prospective clinical study included 100 eyes of 100 patients who underwent vitrectomy alone or phacovitrectomy for macula-off retinal detachment. All patients included signed an informed consent. Preoperative examination of the patients included recording the axial length measurements using optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry. The mean postoperative IOLMaster axial length after macular reattachment was 26.11 ± 2.91 mm. The mean preoperative IOLMaster axial length with macula-off was 25.32 ± 2.72 mm. The mean preoperative A-scan axial length with macula-off was 25.29 ± 2.80 mm. The mean preoperative vector-A/B-scan axial length with macula-off was 26.03 ± 2.90 mm. The preoperative vector-A/B-scan mean absolute error was 0.59 ± 0.48 D (range, 0.10-2.25 D). Regular methods (optical biometry and A-scan biometry) of measuring the axial length in cases with a detached macula proved to be variable and less accurate. The vector-A/B-scan offered good measurements of the actual axial length in the patients. This was reflected on more accurate postoperative refractive outcome. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  9. Measurement of the dechanneling length for high-energy negative pions

    International Nuclear Information System (INIS)

    Scandale, W.; Losito, R.; Bagli, E.; Bandiera, L.; Dalpiaz, P.; Fiorini, M.; Guidi, V.; Mazzolari, A.; Vincenzi, D.; Della Mea, G.; Vallazza, E.; Afonin, A.G.; Chesnokov, Yu.A.; Maisheev, V.A.; Yazynin, I.A.; Kovalenko, A.D.; Taratin, A.M.; Denisov, A.S.; Gavrikov, Yu.A.; Ivanov, Yu.M.

    2013-01-01

    We studied the dechanneling length of 150 GeV/cπ − interacting with a short bent silicon crystal. Dechanneling length measures the rate and the strength of incoherent interactions of channeled particles in a crystal. The mechanism of dechanneling of negatively charged particles has been elucidated through simulation and experiment. It was found that the dechanneling length for negative particles is comparable to the nuclear dechanneling length for positive charges. Indeed, dechanneling of negative particles occurs as a result of incoherent interactions with the nuclei because the trajectories of such particles always intersect atomic planes, explaining the lower channeling efficiency for such particles. Obtained results can be useful for the design of crystals for manipulating high-energy negative particle beams through channeling

  10. Measurement of the diffusion length of thermal neutrons inside graphite

    International Nuclear Information System (INIS)

    Ertaud, A.; Beauge, R.; Fauquez, H.; De Laboulay, H.; Mercier, C.; Vautrey, L.

    1948-11-01

    The diffusion length of thermal neutrons inside a given industrial graphite is determined by measuring the neutron density inside a parallelepipedal piling up of graphite bricks (2.10 x 2.10 x 2.442 m). A 3.8 curies (Ra α → Be) source is placed inside the parallelepipedal block of graphite and thin manganese detectors are used. Corrections are added to the unweighted measurements to take into account the effects of the damping of supra-thermal neutrons in the measurement area. These corrections are experimentally deduced from the differential measurements made with a cadmium screen interposed between the source and the first plane of measurement. An error analysis completes the report. The diffusion length obtained is: L = 45.7 cm ± 0.3. The average density of the graphite used is 1.76 and the average apparent density of the piling up is 1.71. (J.S.)

  11. Utility of telomere length measurements for age determination of humpback whales

    NARCIS (Netherlands)

    Olsen, Morten T.; Robbins, Jooke; Bérubé, Martine; Rew, Mary Beth; Palsboll, Per

    2014-01-01

    This study examines the applicability of telomere length measurements by quantitative PCR as a tool for minimally invasive age determination of free-ranging cetaceans. We analysed telomere length in skin samples from 28 North Atlantic humpback whales (Megaptera novaeangliae), ranging from 0 to 26

  12. Preliminary result of bunch length measurement using a modified Michelson interferometer

    International Nuclear Information System (INIS)

    Lin Xuling; Luo Feng; Bei Hua; Dai Zhimin; Chinese Academy of Sciences, Beijing; Zhang Jianbing; Lu Shanliang; Yu Tiemin

    2009-01-01

    Based on the femtosecond accelerator device which was built at the Shanghai Institute of Applied Physics (SINAP), recently a modified far infrared Michelson interferometer has been developed to measure the length of electron bunches via the optical autocorrelation method. Compared with our former normal Michelson interferometer, we use a hollow retroreflector instead of a flat mirror as the reflective mirror. The experimental setup and results of the bunch length measurement will be described in this paper. (authors)

  13. Optical Arc-Length Sensor For TIG Welding

    Science.gov (United States)

    Smith, Matthew A.

    1990-01-01

    Proposed subsystem of tungsten/inert-gas (TIG) welding system measures length of welding arc optically. Viewed by video camera, in one of three alternative optical configurations. Length of arc measured instead of inferred from voltage.

  14. Blood and dried blood spot telomere length measurement by qPCR: assay considerations.

    Directory of Open Access Journals (Sweden)

    DeAnna L Zanet

    Full Text Available Measurement of telomere length is crucial for the study of telomere maintenance and its role in molecular pathophysiology of diseases and in aging. Several methods are used to measure telomere length, the choice of which usually depends on the type and size of sample to be assayed, as well as cost and throughput considerations. The goal of this study was to investigate the factors that may influence the reliability of qPCR-based relative telomere length measurements in whole blood. Day to day intra-individual variability, types of blood anticoagulant, sample storage conditions, processing and site of blood draw were investigated. Two qPCR-based methods to measure telomere length (monoplex vs. multiplex were also investigated and showed a strong correlation between them. Freezing and thawing of the blood and storage of the blood at 4°C for up to 4 days did not affect telomere length values. Telomere lengths in dried blood spots were significantly higher than both whole blood and peripheral mononuclear blood cells, and were highly correlated with both. We found that telomere length measurements were significantly higher in dried blood spots collected directly from fingertip prick compared to dried blood spots prepared with anticoagulated whole blood collected from the finger, and non-blotted whole blood taken from both finger and arm venipuncture. This suggests that DNA from cells blotted on paper is not equivalent to that collected from venipuncture whole blood, and caution should be taken when comparing between blood sample types.

  15. Assessment of colorectal length using the electromagnetic capsule tracking system: a comparative validation study in healthy subjects.

    Science.gov (United States)

    Mark, E B; Poulsen, J L; Haase, A M; Frøkjaer, J B; Schlageter, V; Scott, S M; Krogh, K; Drewes, A M

    2017-09-01

    We aimed to determine colorectal length with the 3D-Transit system by describing a 'centreline' of capsule movement and comparing it with known anatomy, as determined by magnetic resonance imaging (MRI). Further, we aimed to test the day-to-day variation of colorectal length assessed with the system. The 3D-Transit system consists of electromagnetic capsules that can be tracked as they traverse the gastrointestinal tract. Twenty-five healthy subjects were examined with both 3D-Transit and MRI. Another 21 healthy subjects were examined with 3D-Transit on two consecutive days. Computation of colorectal length from capsule passage was possible for 60 of the 67 3D-Transit recordings. The length of the colorectum measured with MRI and 3D-Transit was 95 (75-153) cm and 99 (77-147) cm, respectively (P = 0.15). The coefficient of variation (CV) between MRI and 3D-Transit was 7.8%. Apart from the caecum/ascending colon being 26% (P = 0.002) shorter on MRI, there were no other differences in total or segmental colorectal lengths between methods (all P > 0.05). The length of the colorectum measured with 3D-Transit on two consecutive days was 102 (73-119) cm and 103 (75-123) cm (P = 0.67). The CV between days was 7.3%. The 3D-Transit system allows accurate and reliable determination of colorectal length compared with MRI-derived colorectal length and between days. Antegrade or retrograde capsule movement relative to this centreline, as well as the length and speed of movements, may be determined by future studies to allow better classification and treatment in patients with dysmotility. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  16. Machine vision system for measuring conifer seedling morphology

    Science.gov (United States)

    Rigney, Michael P.; Kranzler, Glenn A.

    1995-01-01

    A PC-based machine vision system providing rapid measurement of bare-root tree seedling morphological features has been designed. The system uses backlighting and a 2048-pixel line- scan camera to acquire images with transverse resolutions as high as 0.05 mm for precise measurement of stem diameter. Individual seedlings are manually loaded on a conveyor belt and inspected by the vision system in less than 0.25 seconds. Designed for quality control and morphological data acquisition by nursery personnel, the system provides a user-friendly, menu-driven graphical interface. The system automatically locates the seedling root collar and measures stem diameter, shoot height, sturdiness ratio, root mass length, projected shoot and root area, shoot-root area ratio, and percent fine roots. Sample statistics are computed for each measured feature. Measurements for each seedling may be stored for later analysis. Feature measurements may be compared with multi-class quality criteria to determine sample quality or to perform multi-class sorting. Statistical summary and classification reports may be printed to facilitate the communication of quality concerns with grading personnel. Tests were conducted at a commercial forest nursery to evaluate measurement precision. Four quality control personnel measured root collar diameter, stem height, and root mass length on each of 200 conifer seedlings. The same seedlings were inspected four times by the machine vision system. Machine stem diameter measurement precision was four times greater than that of manual measurements. Machine and manual measurements had comparable precision for shoot height and root mass length.

  17. Measuring Clearance Mechanics Based on Dynamic Leg Length

    Science.gov (United States)

    Khamis, Sam; Danino, Barry; Hayek, Shlomo; Carmeli, Eli

    2018-01-01

    The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant…

  18. Simultaneous Water Vapor and Dry Air Optical Path Length Measurements and Compensation with the Large Binocular Telescope Interferometer

    Science.gov (United States)

    Defrere, D.; Hinz, P.; Downey, E.; Boehm, M.; Danchi, W. C.; Durney, O.; Ertel, S.; Hill, J. M.; Hoffmann, W. F.; Mennesson, B.; hide

    2016-01-01

    The Large Binocular Telescope Interferometer uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI/MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current performance of the system for dry air seeing compensation, we present simultaneous H-, K-, and N-band observations that illustrate the feasibility of our feed forward approach to stabilize the path length fluctuations seen by the LBTI nuller uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current

  19. Electron bunch length measurement at the Vanderbilt FEL

    Energy Technology Data Exchange (ETDEWEB)

    Amirmadhi, F.; Brau, C.A.; Mendenhall, M. [Vanderbilt Free-Electron-Laser Center, Nashville, TN (United States)] [and others

    1995-12-31

    During the past few years, a number of experiments have been performed to demonstrate the possibility to extract the longitudinal charge distribution from spectroscopic measurements of the coherent far-infrared radiation emitted as transition radiation or synchrotron radiation. Coherent emission occurs in a spectral region where the wavelength is comparable to or longer than the bunch length, leading to an enhancement of the radiation intensity that is on the order of the number of particles per bunch, as compared to incoherent radiation. This technique is particularly useful in the region of mm and sub-mm bunch lengths, a range where streak-cameras cannot be used for beam diagnostics due to their limited time resolution. Here we report on experiments that go beyond the proof of principle of this technique by applying it to the study and optimization of FEL performance. We investigated the longitudinal bunch length of the Vanderbilt FEL by analyzing the spectrum of coherent transition radiation emitted by the electron bunches. By monitoring the bunch length while applying a bunch-compression technique, the amount of the compression could be easily observed. This enabled us to perform a systematic study of the FEL performance, especially gain and optical pulse width, as a function of the longitudinal electron distribution in the bunch. The results of this study will be presented and discussed.

  20. Single-Camera-Based Method for Step Length Symmetry Measurement in Unconstrained Elderly Home Monitoring.

    Science.gov (United States)

    Cai, Xi; Han, Guang; Song, Xin; Wang, Jinkuan

    2017-11-01

    single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring. To build unconstrained monitoring environments, we propose a method to measure step length symmetry ratio (a useful gait parameter representing gait symmetry without significant relationship with age) from unconstrained straight walking using a single camera, without strict restrictions on walking directions or routes. according to projective geometry theory, we first develop a calculation formula of step length ratio for the case of unconstrained straight-line walking. Then, to adapt to general cases, we propose to modify noncollinear footprints, and accordingly provide general procedure for step length ratio extraction from unconstrained straight walking. Our method achieves a mean absolute percentage error (MAPE) of 1.9547% for 15 subjects' normal and abnormal side-view gaits, and also obtains satisfactory MAPEs for non-side-view gaits (2.4026% for 45°-view gaits and 3.9721% for 30°-view gaits). The performance is much better than a well-established monocular gait measurement system suitable only for side-view gaits with a MAPE of 3.5538%. Independently of walking directions, our method can accurately estimate step length ratios from unconstrained straight walking. This demonstrates our method is applicable for elders' daily gait monitoring to provide valuable information for elderly health care, such as abnormal gait recognition, fall risk assessment, etc. single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring

  1. The elementary school teachers’ ability in the length measurement

    Science.gov (United States)

    Julie, Hongki

    2017-09-01

    The purpose of this study was to describe the elementary school teachers' mathematical ability (1) to develop students’ activities which constructed longer than, shorter than, and as long as concepts, (2) to develop students’ activities which constructed standard unit on the length measurement, and (3) to develop a problem which used by student to construct why a conversion activity on the unit of the length was useful in the daily life after they have participated in the Realistic Mathematics Education (RME) workshops. Curry and Outhread said if teachers knew more about the growth of students’ conceptual understanding of the length, they would be better able to teach that topic [4]. Therefore, in the workshop, teachers were asked to learn more on the stages of the measurement teaching and learning process and why each stage was important. This capability was described by the results of a test which was content of four problems given to teachers after they have attended the workshop. Research subjects in this study were 14 elementary school teachers at Yogyakarta. The results of the study were as follows: (1) only four of 14 teachers who had the first ability; (2) all teachers had the second ability; and (3) all the teachers did not have the third ability.

  2. Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device

    International Nuclear Information System (INIS)

    Gao Long; Yu Boxiang; Ding Yayun

    2013-01-01

    An attenuation length measurement device was constructed using an oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested in a variety of ways. The test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent). Besides, the accuracy of the measurement system will decrease by about 17 percent if a filter is used. The attenuation length of a gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10±0.35 m where Gd-LS was heavily used in the Daya Bay Neutrino Experiment. In addition, one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device, the R-square reached 0.9995. Moreover, three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment. (authors)

  3. Bunch length measurements using electro-optical sampling at the SLS linac

    International Nuclear Information System (INIS)

    Winter, A.

    2004-07-01

    A mode-locked titanium-sapphire laser with 15 fs pulse width is used to determine the time profile of the picosecond electron bunches in the Swiss light source linac of the Paul Scherrer Institute, Villigen Switzerland. This was done using the electro-optic effect in Zinc-Telluride crystals and sampling the change induced by coherent transition radiation with the TiSa laser. The development, implementation and results of an analogue synchronisation system to synchronise the repetition rate of the TiSa laser to the radio frequency of the accelerator with a short term stability of 40 fs is presented. The experimental setup of the bunch length measurements is described and results are presented on the coincidence measurements between the laser pulses and the coherent transition radiation pulses generated by the electron bunches. (orig.)

  4. The Chain-Length Distribution in Subcritical Systems

    International Nuclear Information System (INIS)

    Nolen, Steven Douglas

    2000-01-01

    The individual fission chains that appear in any neutron multiplying system provide a means, via neutron noise analysis, to unlock a wealth of information regarding the nature of the system. This work begins by determining the probability density distributions for fission chain lengths in zero-dimensional systems over a range of prompt neutron multiplication constant (K) values. This section is followed by showing how the integral representation of the chain-length distribution can be used to obtain an estimate of the system's subcritical prompt multiplication (MP). The lifetime of the chains is then used to provide a basis for determining whether a neutron noise analysis will be successful in assessing the neutron multiplication constant, k, of the system in the presence of a strong intrinsic source. A Monte Carlo transport code, MC++, is used to model the evolution of the individual fission chains and to determine how they are influenced by spatial effects. The dissertation concludes by demonstrating how experimental validation of certain global system parameters by neutron noise analysis may be precluded in situations in which the system K is relatively low and in which realistic detector efficiencies are simulated

  5. The Chain-Length Distribution in Subcritical Systems

    Energy Technology Data Exchange (ETDEWEB)

    Nolen, Steven Douglas [Texas A & M Univ., College Station, TX (United States)

    2000-06-01

    The individual fission chains that appear in any neutron multiplying system provide a means, via neutron noise analysis, to unlock a wealth of information regarding the nature of the system. This work begins by determining the probability density distributions for fission chain lengths in zero-dimensional systems over a range of prompt neutron multiplication constant (K) values. This section is followed by showing how the integral representation of the chain-length distribution can be used to obtain an estimate of the system's subcritical prompt multiplication (MP). The lifetime of the chains is then used to provide a basis for determining whether a neutron noise analysis will be successful in assessing the neutron multiplication constant, k, of the system in the presence of a strong intrinsic source. A Monte Carlo transport code, MC++, is used to model the evolution of the individual fission chains and to determine how they are influenced by spatial effects. The dissertation concludes by demonstrating how experimental validation of certain global system parameters by neutron noise analysis may be precluded in situations in which the system K is relatively low and in which realistic detector efficiencies are simulated.

  6. Association between objectively measured physical activity, chronic stress and leukocyte telomere length.

    Science.gov (United States)

    von Känel, Roland; Bruwer, Erna J; Hamer, Mark; de Ridder, J Hans; Malan, Leoné

    2017-10-01

    Physical activity (PA) attenuates chronic stress and age-related and cardiovascular disease risks, whereby potentially slowing telomere shortening. We aimed to study the association between seven-day objectively measured habitual PA, chronic stress and leukocyte telomere length. Study participants were African (N.=96) and Caucasian (N.=107) school teachers of the Sympathetic activity and Ambulatory Blood Pressure in Africans study. All lifestyle characteristics (including PA) were objectively measured. The general health questionnaire and serum cortisol were assessed as psychological and physical measures of chronic stress. Leukocyte telomere length was measured using the quantitative real-time polymerase chain reaction. Africans had significantly shorter telomeres (Pstress or telomere length. However, more time spent with light intensity PA time was significantly and independently correlated with lower waist circumference (r=-0.21, P=0.004); in turn, greater waist circumference was significantly associated shorter telomeres (β=-0.17 [-0.30, -0.03], P=0.017). Habitual PA of different intensity was not directly associated with markers of chronic stress and leukocyte telomere length in this biethnic cohort. However, our findings suggest that light intensity PA could contribute to lowered age-related disease risk and healthy ageing by facilitating maintenance of a normal waist circumference.

  7. [Renal length measured by ultrasound in adult mexican population].

    Science.gov (United States)

    Oyuela-Carrasco, J; Rodríguez-Castellanos, F; Kimura, E; Delgado-Hernández, R; Herrera-Félix, J P

    2009-01-01

    Renal length estimation by ultrasound is an important parameter in clinical evaluation of kidney disease and healthy donors. Changes in renal volume may be a sign of kidney disease. Correct interpretation of renal length requires the knowledge of normal limits, these have not been described for Latin American population. To describe normal renal length (RL) by ultrasonography in a group of Mexican adults. Ultrasound measure of RL in 153 healthy Mexican adults stratified by age. Describe the association of RL to several anthropometric variables. A total of 77 males and 76 females were scanner. The average age for the group was 44.12 +/- 15.44 years. The mean weight, body mass index (BMI) and height were 68.87 +/- 11.69 Kg, 26.77 +/- 3.82 kg/m2 and 160 +/- 8.62 cm respectively. Dividing the population by gender, showed a height of 166 +/- 6.15 cm for males and 154.7 +/- 5.97 cm for females (p =0.000). Left renal length (LRL) in the whole group was 105.8 +/- 7.56 mm and right renal length (RRL) was 104.3 +/- 6.45 mm (p = 0.000.) The LRL for males was 107.16 +/- 6.97 mm and for females was 104.6 +/- 7.96 mm. The average RRL for males was 105.74 +/- 5.74 mm and for females 102.99 +/- 6.85 mm (p = 0.008.) We noted that RL decreased with age and the rate of decline accelerates alter 60 years of age. Both lengths correlated significantly and positively with weight, BMI and height. The RL was significantly larger in males than in females in both kidneys (p = 0.036) in this Mexican population. Renal length declines after 60 years of age and specially after 70 years.

  8. Reliability of length measurements collected by community nurses and health volunteers in rural growth monitoring and promotion services.

    Science.gov (United States)

    Laar, Matilda E; Marquis, Grace S; Lartey, Anna; Gray-Donald, Katherine

    2018-02-17

    Length measurements are important in growth, monitoring and promotion (GMP) for the surveillance of a child's weight-for-length and length-for-age. These two indices provide an indication of a child's risk of becoming wasted or stunted, and are more informative about a child's growth than the widely used weight-for-age index (underweight). Although the introduction of length measurements in GMP is recommended by the World Health Organization, concerns about the reliability of length measurements collected in rural outreach settings have been expressed by stakeholders. Our aim was to describe the reliability and challenges associated with community health personnel measuring length for rural outreach GMP activities. Two reliability studies (A and B), using 10 children less than 24 months each, were conducted in the GMP services of a rural district in Ghana. Fifteen nurses and 15 health volunteers (HV) with no prior experience in length measurements were trained. Intra- and inter-observer technical error of measurement (TEM), average bias from expert anthropometrist, and coefficient of reliability (R) of length measurements were assessed and compared across sessions. Observations and interviews were used to understand the ability and experiences of health personnel with measuring length at outreach GMP. Inter-observer TEM was larger than intra-observer TEM for both nurses and HV at both sessions and was unacceptably (compared to error standards) high in both groups at both time points. Average biases from expert's measurements were within acceptable limits, however, both groups tended to underestimate length measurements. The R for lengths collected by nurses (92.3%) was higher at session B compared to that of HV (87.5%). Length measurements taken by nurses and HV, and those taken by an experienced anthropometrist at GMP sessions were of moderate agreement (kappa = 0.53, p reliability of length measurements improved after two refresher trainings for nurses but

  9. Validation of Navigation Ultrasound for Clavicular Length Measurement

    DEFF Research Database (Denmark)

    Høj, Anders Thorsmark; Villa, Chiara; Christensen, Ole M.

    2017-01-01

    interval): approximately ± 7.5 mm, Pearson's correlation R: 0.948-0.974). Navigation ultrasound can measure clavicular length with an intra-rater reliability matching that of 3-D rendered computed tomography scans and with high validity. Its use could spread to other fields requiring accurate...... of 52.5 (range: 21-78 y) were included. Navigation ultrasound exhibited high reliability (intra-class correlation coefficient: 0.942-0.997, standard error of the mean: 0.7-2.9 mm, minimal detectable change: 2.3-8.1 mm) and validity (measurement error: 1.3%-1.8%, limits of agreement (95% confidence...

  10. Reliability and short-term intra-individual variability of telomere length measurement using monochrome multiplexing quantitative PCR.

    Directory of Open Access Journals (Sweden)

    Sangmi Kim

    Full Text Available Studies examining the association between telomere length and cancer risk have often relied on measurement of telomere length from a single blood draw using a real-time PCR technique. We examined the reliability of telomere length measurement using sequential samples collected over a 9-month period.Relative telomere length in peripheral blood was estimated using a single tube monochrome multiplex quantitative PCR assay in blood DNA samples from 27 non-pregnant adult women (aged 35 to 74 years collected in 7 visits over a 9-month period. A linear mixed model was used to estimate the components of variance for telomere length measurements attributed to variation among women and variation between time points within women. Mean telomere length measurement at any single visit was not significantly different from the average of 7 visits. Plates had a significant systematic influence on telomere length measurements, although measurements between different plates were highly correlated. After controlling for plate effects, 64% of the remaining variance was estimated to be accounted for by variance due to subject. Variance explained by time of visit within a subject was minor, contributing 5% of the remaining variance.Our data demonstrate good short-term reliability of telomere length measurement using blood from a single draw. However, the existence of technical variability, particularly plate effects, reinforces the need for technical replicates and balancing of case and control samples across plates.

  11. Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP

    CERN Document Server

    Boccard, C; Papis, J P; Vos, L

    1995-01-01

    We describe a system which is used operationally to measure the absolute intensity of single lepton bunches in a beam transfer line. It is based on the detailed knowledge of every single item of a complex measuring chain that comprises a beam coupler on one end and an acquisition system on the other end. This knowledge can be acquired by a well tested theoretical model and careful measurement of the transfer function of each processing module. A precision better than 3 % can be obtained and no external calibration is required. A value for the bunch length can be deduced from a spectral intensity measurement at two well chosen frequencies.

  12. Microdose acquisition in adolescent leg length discrepancy using a low-dose biplane imaging system

    DEFF Research Database (Denmark)

    Jensen, Janni; Mussmann, Bo Redder; Hjarbæk, John

    2017-01-01

    To compare leg length measurements performed on diagnostic images and low dose preview images both acquired using a low-dose bi-planar imaging system. Material and Methods Preview and diagnostic images from 22 patients were retrospectively collected (14 girls, 8 boys; mean age, 12.8 years; age range, 10......-15 years). All images were anonymized and measured independently by two musculoskeletal radiologists. Three sets of measurements were performed on all images; the mechanical axis lines of the femur and the tibia as well as the anatomical line of the entire extremity. Statistical significance was tested...... with a paired t-test. Results No statistically significant difference was found between measurements performed on the preview and on the diagnostic image. The mean tibial length difference between the observers was -0.06 cm (95% confidence interval [CI], -0.12 to 0.01) and -0.08 cm (95% CI, -0.21 to 0...

  13. Ultrashort electron bunch length measurement with diffraction radiation deflector

    Science.gov (United States)

    Xiang, Dao; Huang, Wen-Hui

    2007-01-01

    In this paper, we propose a novel method to measure electron bunch length with a diffraction radiation (DR) deflector which is composed of a DR radiator and three beam position monitors (BPMs). When an electron beam passes through a metallic aperture which is tilted by 45 degrees with respect to its trajectory, backward DR that propagates perpendicular to the beam’s trajectory is generated which adds a transverse deflection to the beam as a result of momentum conservation. The deflection is found to be largely dependent on the bunch length and could be easily observed with a downstream BPM. Detailed investigations show that this method has wide applicability, high temporal resolution, and great simplicity.

  14. Ultrashort electron bunch length measurement with diffraction radiation deflector

    Directory of Open Access Journals (Sweden)

    Dao Xiang

    2007-01-01

    Full Text Available In this paper, we propose a novel method to measure electron bunch length with a diffraction radiation (DR deflector which is composed of a DR radiator and three beam position monitors (BPMs. When an electron beam passes through a metallic aperture which is tilted by 45 degrees with respect to its trajectory, backward DR that propagates perpendicular to the beam’s trajectory is generated which adds a transverse deflection to the beam as a result of momentum conservation. The deflection is found to be largely dependent on the bunch length and could be easily observed with a downstream BPM. Detailed investigations show that this method has wide applicability, high temporal resolution, and great simplicity.

  15. Reliability of linear distance measurement for dental implant length with standardized periapical radiographs

    International Nuclear Information System (INIS)

    Wakoh, Mamoru; Harada, Takuya; Otonari, Takamichi

    2006-01-01

    The purpose of this study was to investigate the accuracy of distance measurements of implant length based on periapical radiographs compared with that of other modalities. We carried out an experimental trial to compare precision in distance measurement. Dental implant fixtures were buried in the canine and first molar regions. These were then subjected to periapical (PE) radiography, panoramic (PA) radiography conventional (CV) and medical computed (CT) tomography. The length of the implant fixture on each film was measured by nine observers and degree of precision was statistically analyzed. The precision of both PE radiographs and CT tomograms was closest at the highest level. Standardized PE radiography, in particular, was superior to CT tomography in the first molar region. This suggests that standardized PE radiographs should be utilized as a reliable modality for longitudinal and linear distance measurement, depending on implant length at local implantation site. (author)

  16. Fully automated system for pulsed NMR measurements

    International Nuclear Information System (INIS)

    Cantor, D.M.

    1977-01-01

    A system is described which places many of the complex, tedious operations for pulsed NMR experiments under computer control. It automatically optimizes the experiment parameters of pulse length and phase, and precision, accuracy, and measurement speed are improved. The hardware interface between the computer and the NMR instrument is described. Design features, justification of the choices made between alternative design strategies, and details of the implementation of design goals are presented. Software features common to all the available experiments are discussed. Optimization of pulse lengths and phases is performed via a sequential search technique called Uniplex. Measurements of the spin-lattice and spin-spin relaxation times and of diffusion constants are automatic. Options for expansion of the system are explored along with some of the limitations of the system

  17. Two independent measurements of Debye lengths in doped nonpolar liquids.

    Science.gov (United States)

    Prieve, D C; Hoggard, J D; Fu, R; Sides, P J; Bethea, R

    2008-02-19

    Electric current measurements were performed between 2.5 cm x 7.5 cm parallel-plate electrodes separated by 1.2 mm of heptane doped with 0-15% w/w poly(isobutylene succinimide) (PIBS) having a molecular weight of about 1700. The rapid (microsecond) initial charging of the capacitor can be used to infer the dielectric constant of the solution. The much slower decay of current arising from the polarization of electrodes depends on the differential capacitance of the diffuse clouds of charge carriers accumulating next to each electrode and on the ohmic resistance of the fluid. Using the Gouy-Chapman model for the differential capacitance, Debye lengths of 80-600 nm were deduced that decrease with increasing concentration of PIBS. Values of the Debye lengths were confirmed by performing independent measurements of double-layer repulsion between a 6 microm polystyrene (PS) latex sphere and a PS-coated glass plate using total internal reflection microscopy in the same solutions. The charge carriers appear to be inverted PIBS micelles having apparent Stokes diameters of 20-40 nm. Dynamic light scattering reveals a broad distribution of sizes having an intensity-averaged diameter of 15 nm. This smaller size might arise (1) from overestimating the electrophoretic mobility of micelles by treating them as point charges or (2) because charged micelles are larger on average than uncharged micelles. When Faradaic reactions and zeta potentials on the electrodes can be neglected, such current versus time experiments yield values for the Debye length and ionic strength with less effort than force measurements. To obtain the concentration of charge carriers from measurements of conductivity, the mobility of the charge carriers must be known.

  18. Measurement of the length and position of the lower oesophageal sphincter by correlation of external measurements and radiographic estimations in dogs

    International Nuclear Information System (INIS)

    Waterman, A.E.; Hashim, M.A.

    1991-01-01

    Fifty dogs were investigated in order to correlate the length and position of the lower oesophageal sphincter (LOS) with external measurements. Various external measurements were taken while the dogs were anaesthetised and positioned in lateral recumbency. An oesophageal tube was then introduced into the oesophagus and thoracic radiographs were taken. The 'real internal length of the oesophagus' was calculated as the length from the lower jaw incisor tooth to the position of the oesophageal tube at the costal border of the diaphragm. A highly significant linear correlation was found between this internal length and the external length from lower jaw incisor tooth to the anterior border of the head of the 10th rib. Using oesophageal manometry, the length and position of the LOS was also studied in 25 clinically normal bitches. The mean length of the LOS was found to be 4.6 +/- 0.92 cm. The position of the LOS was a mean of 4.4 +/- 1.69 cm cranial to the costal border of the diaphragm. The findings of this study indicate that the external measurements can be used to position catheters for accurate oesophageal manometry in the dog

  19. Effect of e-learning on quality of cervical-length measurements.

    Science.gov (United States)

    van Os, M A; van der Ven, A J; Bloemendaal, P M; Pajkrt, E; de Groot, C J M; Mol, B W J; Haak, M C

    2015-09-01

    To assess the effect of implementation of a newly developed e-learning module on the quality of cervical-length measurements. With the introduction of cervical-length (CL) measurement in a research setting, a CL measurement e-learning module (CLEM) was developed with the purpose to enhance the knowledge and skills of experienced ultrasonographers. CLEM was designed specifically for ultrasonographers who perform ultrasound in a general obstetrical practice but who do not regularly perform CL measurements. CLEM consists of five theoretical questions and three caliper-placement tests to learn the CL measurement technique. The quality of the CL measurements of CLEM participants was compared with images of non-participants using a CL measurement image score (CIS), defined as the sum of six items which assess the quality of the image. Each CLEM participant submitted five CL images and the images of non-CLEM participants were selected randomly from an ultrasound database. The CIS of the CLEM participants (n = 61) were significantly higher than those of non-CLEM participants (n = 23) (164.9 vs 155.6, respectively; P = 0.03). Visualization of the internal os and positioning of the calipers on the internal and external ora were found to have significantly higher CIS among the CLEM participants than among the non-CLEM participants (P = 0.001 and P < 0.001, respectively). Introducing CLEM may improve the quality of CL measurements obtained by trained and untrained sonographers. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  20. Length scales in glass-forming liquids and related systems: a review

    International Nuclear Information System (INIS)

    Karmakar, Smarajit; Dasgupta, Chandan; Sastry, Srikanth

    2016-01-01

    The central problem in the study of glass-forming liquids and other glassy systems is the understanding of the complex structural relaxation and rapid growth of relaxation times seen on approaching the glass transition. A central conceptual question is whether one can identify one or more growing length scale(s) associated with this behavior. Given the diversity of molecular glass-formers and a vast body of experimental, computational and theoretical work addressing glassy behavior, a number of ideas and observations pertaining to growing length scales have been presented over the past few decades, but there is as yet no consensus view on this question. In this review, we will summarize the salient results and the state of our understanding of length scales associated with dynamical slow down. After a review of slow dynamics and the glass transition, pertinent theories of the glass transition will be summarized and a survey of ideas relating to length scales in glassy systems will be presented. A number of studies have focused on the emergence of preferred packing arrangements and discussed their role in glassy dynamics. More recently, a central object of attention has been the study of spatially correlated, heterogeneous dynamics and the associated length scale, studied in computer simulations and theoretical analysis such as inhomogeneous mode coupling theory. A number of static length scales have been proposed and studied recently, such as the mosaic length scale discussed in the random first-order transition theory and the related point-to-set correlation length. We will discuss these, elaborating on key results, along with a critical appraisal of the state of the art. Finally we will discuss length scales in driven soft matter, granular fluids and amorphous solids, and give a brief description of length scales in aging systems. Possible relations of these length scales with those in glass-forming liquids will be discussed. (review article)

  1. Influence of crack length on crack depth measurement by an alternating current potential drop technique

    International Nuclear Information System (INIS)

    Raja, Manoj K; Mahadevan, S; Rao, B P C; Behera, S P; Jayakumar, T; Raj, Baldev

    2010-01-01

    An alternating current potential drop (ACPD) technique is used for sizing depth of surface cracks in metallic components. Crack depth estimations are prone to large deviations when ACPD measurements are made on very shallow and finite length cracks, especially in low conducting materials such as austenitic stainless steel (SS). Detailed studies have been carried out to investigate the influence of crack length and aspect ratio (length to depth) on depth estimation by performing measurements on electric discharge machined notches with the aspect ratio in the range of 1 to 40 in SS plates. In notches with finite length, an additional path for current to flow through the surface along the length is available causing the notch depths to be underestimated. The experimentally observed deviation in notch depth estimates is explained from a simple mathematical approach using the equivalent resistive circuit model based on the additional path available for the current to flow. A scheme is proposed to accurately measure the depth of cracks with finite lengths in SS components

  2. Measurement of Telomere Length in Colorectal Cancers for Improved Molecular Diagnosis

    Directory of Open Access Journals (Sweden)

    Eric Le Balc’h

    2017-08-01

    Full Text Available All tumors have in common to reactivate a telomere maintenance mechanism to allow for unlimited proliferation. On the other hand, genetic instability found in some tumors can result from the loss of telomeres. Here, we measured telomere length in colorectal cancers (CRCs using TRF (Telomere Restriction Fragment analysis. Telomeric DNA content was also quantified as the ratio of total telomeric (TTAGGG sequences over that of the invariable Alu sequences. In most of the 125 CRCs analyzed, there was a significant diminution in telomere length compared with that in control healthy tissue. Only 34 tumors exhibited no telomere erosion and, in some cases, a slight telomere lengthening. Telomere length did not correlate with age, gender, tumor stage, tumor localization or stage of tumor differentiation. In addition, while telomere length did not correlate with the presence of a mutation in BRAF (V-raf murine sarcoma viral oncogene homolog B, PIK3CA (phosphatidylinositol 3-kinase catalytic subunit, or MSI status, it was significantly associated with the occurrence of a mutation in KRAS. Interestingly, we found that the shorter the telomeres in healthy tissue of a patient, the larger an increase in telomere length in the tumor. Our study points to the existence of two types of CRCs based on telomere length and reveals that telomere length in healthy tissue might influence telomere maintenance mechanisms in the tumor.

  3. Stability of measures from children's interviews: the effects of time, sample length, and topic.

    Science.gov (United States)

    Heilmann, John; DeBrock, Lindsay; Riley-Tillman, T Chris

    2013-08-01

    The purpose of this study was to examine the reliability of, and sources of variability in, language measures from interviews collected from young school-age children. Two 10-min interviews were collected from 20 at-risk kindergarten children by an examiner using a standardized set of questions. Test-retest reliability coefficients were calculated for 8 language measures. Generalizability theory (G-theory) analyses were completed to document the variability introduced into the measures from the child, session, sample length, and topic. Significant and strong reliability correlation coefficients were observed for most of the language sample measures. The G-theory analyses revealed that most of the variance in the language measures was attributed to the child. Session, sample length, and topic accounted for negligible amounts of variance in most of the language measures. Measures from interviews were reliable across sessions, and the sample length and topic did not have a substantial impact on the reliability of the language measures. Implications regarding the clinical feasibility of language sample analysis for assessment and progress monitoring are discussed.

  4. Measurement of molecular length of self-assembled monolayer probed by localized surface plasmon resonance

    Science.gov (United States)

    Ito, Juri; Kajikawa, Kotaro

    2016-02-01

    We propose a method to measure the variation of the molecular length of self-assembled monolayers (SAMs) when it is exposed to solutions at different pH conditions. The surface immobilized gold nanospheres (SIGNs) shows strong absorption peak at the wavelengths of 600-800 nm when p-polarized light is illuminated. The peak wavelength depends on the length of the gap distance between the SIGNs and the substrate. The gap is supported by the SAM molecules. According to the analytical calculation based on multiple expansion, the relation between the peak wavelength of the SIGN structures and the gap distance is calculated, to evaluate the molecular length of the SAM through the optical absorption spectroscopy for the SIGN structures. The molecular length of the SIGN structure was measured in air, water, acidic, and basic solutions. It was found that the molecular lengths are longer in acidic solutions.

  5. An Air Bearing Rotating Coil Magnetic Measurement System

    CERN Document Server

    Gottschalk, Stephen C; Taylor, David J; Thayer, William

    2005-01-01

    This paper describes a rotating coil magnetic measurement system supported on air bearings. The design is optimized for measurements of 0.1micron magnetic centerline changes on long, small aperture quadrupoles. Graphite impregnated epoxy resin is used for the coil holder and coil winding forms. Coil holder diameter is 11 mm with a length between supports of 750mm. A pair of coils is used to permit quadrupole bucking during centerline measurements. Coil length is 616mm, inner radius 1.82mm, outer radius 4.74mm. The key features of the mechanical system are simplicity; air bearings for accurate, repeatable measurements without needing warm up time and a vibration isolated stand that uses a steel-topped Newport optical table with air suspension. Coil rotation is achieved by a low noise servo motor controlled by a standalone Ethernet servo board running custom servo software. Coil calibration procedures that correct wire placement errors, tests for mechanical resonances, and other system checks will also be discu...

  6. Quantum discord length is enhanced while entanglement length is not by introducing disorder in a spin chain.

    Science.gov (United States)

    Sadhukhan, Debasis; Roy, Sudipto Singha; Rakshit, Debraj; Prabhu, R; Sen De, Aditi; Sen, Ujjwal

    2016-01-01

    Classical correlation functions of ground states typically decay exponentially and polynomially, respectively, for gapped and gapless short-range quantum spin systems. In such systems, entanglement decays exponentially even at the quantum critical points. However, quantum discord, an information-theoretic quantum correlation measure, survives long lattice distances. We investigate the effects of quenched disorder on quantum correlation lengths of quenched averaged entanglement and quantum discord, in the anisotropic XY and XYZ spin glass and random field chains. We find that there is virtually neither reduction nor enhancement in entanglement length while quantum discord length increases significantly with the introduction of the quenched disorder.

  7. Paediatric renal length measurements from ultrasound and DMSA scans: does clinical practice reflect theoretical normal values?

    International Nuclear Information System (INIS)

    Que, L.; Rutland, M.D.; Hassan, I.M.

    1999-01-01

    Full text: Renal length measurement is a routine part of ultrasound examination in children and those results are plotted on a normogram style graph, so that each child's results are compared to a normal range (mean ± 2 S.D.). Renal length measurements from the posterior oblique views of dimercaptosuccinic acid (DMSA) scans in our department have not always correlated well with the ultrasound measurements on the same patients. Renal lengths from the DMSA scans of 120 patients with apparently normal kidneys were recorded and used to generate a normogram of renal length at different ages (0.5-7 years). This DMSA normogram was compared to the ultrasound (US) normogram used in the Paediatric Radiology Department, and it showed slight differences in renal lengths (3-8 mm), but that the US normogram had smaller coefficients of variation (US = 6.6%, NM 8.3%), implying a 'tighter' normal range. 39 of these patients had DMSA and ultrasound measurements of renal length within 3 months, and these were studied first by calculating the mean and CV values for different age groups, and then by plotting individual renal lengths on the appropriate normograms. The measured data produced much greater variability in the ultrasound measurements than the DTPA measurements, and the individual points produced 4/78 (5.1%) abnormal results for DMSA, but 21/78 (26.9%) abnormal results for ultrasound. Thus, in routine clinical use, using patients with apparently normal kidneys, ultrasound was unable to match the 'normal range' set by their current normogram, but the nuclear medicine showed 5.1% of values outside the normal (DMSA) range, which was completely appropriate for a range of ± 2 standard deviations

  8. Measurements of electric charge and screening length of microparticles in a plasma sheath

    International Nuclear Information System (INIS)

    Nakamura, Y.; Ishihara, O.

    2009-01-01

    An experiment is described in which microparticles are levitated within a rf sheath above a conducting plate in argon plasma. The microparticles forming a two-dimensional crystal structure are considered to possess Debye screening Coulomb potential φ(r)=(Q/4πε 0 r)exp(-r/λ), where Q is the electric charge, r is distance, and λ is the screening length. When the crystal structure is slanted with an angle θ, a particle experiences a force Mg sin θ, where M is the mass of the particle and g is acceleration due to gravity, which must be equal to the Debye screened Coulomb force from other particles. By changing θ, relations for λ(Q) are measured. The screening length λ and Q are determined uniquely from the crossing points of several relations. The electric charge Q is also estimated from a floating potential measured with a probe. The measured λ is nearly equal to an ion Debye length.

  9. Dynamic Length Metrology (DLM) for measurements with sub-micrometre uncertainty in a production environment

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Hansen, Hans Nørgaard; Hattel, Jesper Henri

    2016-01-01

    Conventional length metrology for traceable accurate measurements requires costly temperature controlled facilities, long waiting time for part acclimatisation, and separate part material characterisation. This work describes a method called Dynamic Length Metrology (DLM) developed to achieve sub...

  10. [Methods of measuring telomere length and telomerase activity--practice and problems].

    Science.gov (United States)

    Saito, Y; Suda, T; Hatakeyama, K

    1998-05-01

    The development of a highly sensitive method for detection of telomerase activity, telomeric repeat amplification protocol (TRAP), has provided knowledge on telomerase activity in normal and cancer tissues. Subsequent several modifications have been achieved, including an introduction of the internal standard and hybridization protection technique that leads to simplicity and improvement of reproducibility and linearity of this method, and application of TRAP to in situ analysis to identify the cells responsible for telomerase activity. As for measurement of telomere length, fluorescence in situ hybridization technique appeared to give an information of telomere length on an individual chromosome in contrast to analysis of terminal restriction fragment, a conventional method which can express mean telomere length of all chromosomes. Further methodological improvement in this field is ongoing and showing a new sight on cell mortality and immortality.

  11. Individual stem value recovery of modified and conventional tree-length systems in the southeastern United States

    Science.gov (United States)

    Amanda H. Lang; Shawn A. Baker; W. Dale Greene; Glen E. Murphy

    2010-01-01

    We compared value recovery of a modified treelength (MTL) logging system that measures product diameter and length using a Waratah 626 harvester head to that of a treelength (TL) system that estimates dimensions. A field test compared the actual value cut to the maximum potential value suggested by the log bucking optimization program Assessment of Value by Individual...

  12. Automatic Control Of Length Of Welding Arc

    Science.gov (United States)

    Iceland, William F.

    1991-01-01

    Nonlinear relationships among current, voltage, and length stored in electronic memory. Conceptual microprocessor-based control subsystem maintains constant length of welding arc in gas/tungsten arc-welding system, even when welding current varied. Uses feedback of current and voltage from welding arc. Directs motor to set position of torch according to previously measured relationships among current, voltage, and length of arc. Signal paths marked "calibration" or "welding" used during those processes only. Other signal paths used during both processes. Control subsystem added to existing manual or automatic welding system equipped with automatic voltage control.

  13. Stern potential and Debye length measurements in dilute ionic solutions with electrostatic force microscopy.

    Science.gov (United States)

    Kumar, Bharat; Crittenden, Scott R

    2013-11-01

    We demonstrate the ability to measure Stern potential and Debye length in dilute ionic solution with atomic force microscopy. We develop an analytic expression for the second harmonic force component of the capacitive force in an ionic solution from the linearized Poisson-Boltzmann equation. This allows us to calibrate the AFM tip potential and, further, obtain the Stern potential of sample surfaces. In addition, the measured capacitive force is independent of van der Waals and double layer forces, thus providing a more accurate measure of Debye length.

  14. Neutron chain length distributions in subcritical systems

    International Nuclear Information System (INIS)

    Nolen, S.D.; Spriggs, G.

    1999-01-01

    In this paper, the authors present the results of the chain-length distribution as a function of k in subcritical systems. These results were obtained from a point Monte Carlo code and a three-dimensional Monte Carlo code, MC++. Based on these results, they then attempt to explain why several of the common neutron noise techniques, such as the Rossi-α and Feynman's variance-to-mean techniques, are difficult to perform in highly subcritical systems using low-efficiency detectors

  15. Standardization of methods of expressing lengths and weights of fish

    Science.gov (United States)

    Hile, Ralph

    1948-01-01

    Fishery workers in the United States and Canada are unable to think readily in terms of the metric system of weights and measurements. Even long experience does not make it possible to form a clear idea as to the actual size of fish for which lengths and weights are given in metric units, without first converting to the English system. A more general adoption of the English system of weights and measurements in fishery work is recommended. The use of English units exclusively is suggested for articles of a popular or semi-popular nature, but in more formal publications the key information, at least, should be recorded in both systems. In highly technical papers metric units alone may prove satisfactory. Agreement is also lacking as to which length measurement of fish is suited best for uniform adoption. The total length is recommended here for the reason that it is the only measurement that includes all of the fish. This length is defined as the distance from the tip of the head (jaws closed) to the tip of the tail with the lobes compressed so as to give the maximum possible measurement.

  16. Air refractometry in a length comparator and the response to changes in the measurement environment

    Energy Technology Data Exchange (ETDEWEB)

    Pieles, H

    1998-11-01

    Two different interference refractometers and one air parameter set-up are simultaneously operated in a temperature-stabilized casing of a length comparator. They allow absolute and relative measurements and calculations, respectively of the refractive index of air to be carried out for continuous interferometric length measurements. Measurement results are presented which were obtained under optimized environmental conditions. In addition, sources of disturbances are described which can significantly influence the measurements of the refractive index of air, and consequently may influence the accuracy of interferometric displacement measurements. (orig.)

  17. Frequency dependence of localization length of an electromagnetic wave in a one-dimensional system

    International Nuclear Information System (INIS)

    Vinogradov, A.P.; Merzlikin, A.M.

    2003-01-01

    It is shown that the existence in the high-frequency limit of the localization length of an electromagnetic wave in a randomly layered system requires the presence of an infinitely large number of layers with different incommensurable optical paths. Moreover, the measure of the layers with optical paths that are multiples of any real number should equal zero. The localization length in the high-frequency limit is determined by the mean value of the layer thickness and impedance distribution only. The scaling behavior L loc (k 0 )∼k 0 -2 is observed only if the mean value tends to zero (corresponding to a delta-correlated process)

  18. Bunch length and impedance measurements in SPEAR

    International Nuclear Information System (INIS)

    Bane, K.; Donald, M.; Hofmann, A.; Jowett, J.; Lockman, W.; Morton, P.; Stege, R.; Spence, W.; Wilson, P.

    1988-05-01

    Subsequent to an extensive smoothing of the vacuum chamber a comprehensive study of the SPEAR impedance was undertaken. Bunch length, synchrotron quadrupole mode frequency, and parasitic mode loss were measured as functions of beam current. The results showed that, although the gross longitudinal impedance had indeed been reduced, the 'capacitive' component had also decreased relative to the 'inductive'--to the extent that previously compensated potential well distortion now induced bunch lengthening at low currents, and the turbulent threshold had actually been lowered. A specially designed multi-cell disc-loaded 'capacitor' cavity was shown to be capable of removing this effect by restoring the original compensation. A model of the new SPEAR impedance is also obtained. 7 refs., 6 figs

  19. Bunch length and impedance measurements in SPEAR

    International Nuclear Information System (INIS)

    Bane, K.; Donald, M.; Morton, P.; Stege, R.; Spence, W.; Wilson, P.; Hofmann, A.; Jowett, J.; Lockman, W.

    1988-01-01

    Subsequent to an extensive smoothing of the vacuum chamber a comprehensive study of the SPEAR impedance was undertaken. Bunch length, synchrotron quadrupole mode frequency, and parasitic mode loss were measured as functions of beam current. This paper shows that although the gross longitudinal impedance had indeed been reduced, the capacitive component had also decreased relative to the inductive - to the extent that previously compensated potential well distortion now induced bunch lengthening at low currents, and the turbulent threshold had actually been lowered. A specially designed multi-cell disc-loaded capacitor cavity was shown to be capable of removing this effect by restoring the original compensation. A model of the new SPEAR impedance is also obtained

  20. Measurement of neutron diffusion length in heavy concrete

    International Nuclear Information System (INIS)

    Krejci, D.

    2007-04-01

    Using an aluminium sampler filled with heavy concrete the neutron diffusion length was determined, measuring thermal and fast neutrons over the whole beam hole with various threshold detectors using gold samples. These calculations should describe the neutron distribution in the whole concrete shield of the reactor and contribute to the investigation of the activation of the concrete shield using reactor parameters like operating time, power and neutron flux. Instrumentation, activation and positioning of the samples in the beam hole of the TRIGA Mark II reactor are described. (nevyjel)

  1. Stern potential and Debye length measurements in dilute ionic solutions with electrostatic force microscopy

    International Nuclear Information System (INIS)

    Kumar, Bharat; Crittenden, Scott R

    2013-01-01

    We demonstrate the ability to measure Stern potential and Debye length in dilute ionic solution with atomic force microscopy. We develop an analytic expression for the second harmonic force component of the capacitive force in an ionic solution from the linearized Poisson–Boltzmann equation. This allows us to calibrate the AFM tip potential and, further, obtain the Stern potential of sample surfaces. In addition, the measured capacitive force is independent of van der Waals and double layer forces, thus providing a more accurate measure of Debye length. (paper)

  2. Computer controlled scanning systems for quantitative track measurements

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Preston, C.C.; Ruddy, F.H.

    1982-01-01

    The status of three computer cntrolled systems for quantitative track measurements is described. Two systems, an automated optical track scanner (AOTS) and an automated scanning electron microscope (ASEM) are used for scanning solid state track recorders (SSTR). The third system, the emulsion scanning processor (ESP), is an interactive system used to measure the length of proton tracks in nuclear research emulsions (NRE). Recent advances achieved with these systems are presented, with emphasis placed upon the current limitation of these systems for reactor neutron dosimetry

  3. Cervical Length & Leading Placental Edge to Internal OS Measurements - TA vs TV

    DEFF Research Database (Denmark)

    Westerway, Sue Campbell; Pedersen, Lars Henning; Hyett, Jon

    Brief Description of the Purpose of the Study: To compare cervical length/leading placental edge from the internal cervical os measurements obtained by both transabdominal (TA) and transvaginal (TV) approach and to assess intra / inter-observer variation for these measurements. Methods: Cross...... sectional study of 374 consecutive pregnancies with gestation 12 weeks to term. The cervical length was estimated as the distance from internal to external os, and the placenta / cervix distance as the leading placental edge to internal cervical os. Bland-Altman plots were used to evaluate the two methods....... Importance of the Conclusions: TA estimates of cervix and placental edge position did not reflect the estimates obtained by TV assessment. As both measures are important markers of pregnancy outcome and management, the transabdominal method in the present form is insuffi- cient in clinical management....

  4. Assessing thermally induced errors of machine tools by 3D length measurements

    NARCIS (Netherlands)

    Florussen, G.H.J.; Delbressine, F.L.M.; Schellekens, P.H.J.

    2003-01-01

    A new measurement technique is proposed for the assessment of thermally induced errors of machine tools. The basic idea is to measure changes of length by a telescopic double ball bar (TDEB) at multiple locations in the machine's workspace while the machine is thermally excited. In addition thermal

  5. 16 CFR 500.12 - Measurement of commodities by length and width, how expressed.

    Science.gov (United States)

    2010-01-01

    ... square foot (929 cm2) be expressed in terms of length and width in linear measure. The customary inch... of 1 square foot (929 cm2) or more, but less than 4 square feet (37.1 dm2), be expressed in terms of... (10.16 cm) or less, the declaration of net quantity shall be expressed in terms of width and length in...

  6. The Length of a Pestle: A Class Exercise in Measurement and Statistical Analysis.

    Science.gov (United States)

    O'Reilly, James E.

    1986-01-01

    Outlines the simple exercise of measuring the length of an object as a concrete paradigm of the entire process of making chemical measurements and treating the resulting data. Discusses the procedure, significant figures, measurement error, spurious data, rejection of results, precision and accuracy, and student responses. (TW)

  7. A robotic vision system to measure tree traits

    Science.gov (United States)

    The autonomous measurement of tree traits, such as branching structure, branch diameters, branch lengths, and branch angles, is required for tasks such as robotic pruning of trees as well as structural phenotyping. We propose a robotic vision system called the Robotic System for Tree Shape Estimati...

  8. The influence of humidity on accuracy length measurement on polymer parts

    DEFF Research Database (Denmark)

    Madruga, Daniel González; Alexiou, A.; Dalla Costa, Giuseppe

    2016-01-01

    The work deals with an experimental study of the influence of humidity on accurate length measurements on ABS parts. Polymer parts absorb water from the ambient until they reach hygroscopic equilibrium. Water content causes an expansion of the polymer part. The relationship between the water cont...

  9. Measurements of fatigue crack length at elevated temperature by D. C. electrical potential method

    International Nuclear Information System (INIS)

    Matsumoto, Masakatsu; Yamauchi, Isamu; Kodaira, Tsuneo

    1982-07-01

    The direct current (d.c.) electrical potential method was used to automatically and continuously measure the crack length in cyclic crack growth test at elevated temperature. This report describes some results concerning the calibration curves, i.e. the relation between electrical potential change and amount of crack extention, using SUS 304 and 2 1/4Cr-1Mo steels. It can be concluded that the measurements of fatigue crack length is possible even at elevated temperature as well as at room temperature with the equivalent accuracy. (author)

  10. [Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

    Science.gov (United States)

    Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel

    2013-01-01

    This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.

  11. Effects of energy chirp on bunch length measurement in linear accelerator beams

    Science.gov (United States)

    Sabato, L.; Arpaia, P.; Giribono, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Vaccarezza, C.; Variola, A.

    2017-08-01

    The effects of assumptions about bunch properties on the accuracy of the measurement method of the bunch length based on radio frequency deflectors (RFDs) in electron linear accelerators (LINACs) are investigated. In particular, when the electron bunch at the RFD has a non-negligible energy chirp (i.e. a correlation between the longitudinal positions and energies of the particle), the measurement is affected by a deterministic intrinsic error, which is directly related to the RFD phase offset. A case study on this effect in the electron LINAC of a gamma beam source at the Extreme Light Infrastructure-Nuclear Physics (ELI-NP) is reported. The relative error is estimated by using an electron generation and tracking (ELEGANT) code to define the reference measurements of the bunch length. The relative error is proved to increase linearly with the RFD phase offset. In particular, for an offset of {{7}\\circ} , corresponding to a vertical centroid offset at a screen of about 1 mm, the relative error is 4.5%.

  12. Concordance and interchangeability of biometric measurements of ocular axial length in patients awaiting cataract surgery.

    Science.gov (United States)

    Martín-Serrano, María José; Roman-Ortiz, Carmen; Villa-Sáez, M Luz; Labrador-Castellanos, M Purificación; Blanco-Carrasco, Rosario; Lozano-Ballesteros, Felicidad; Pedraza-Martín, Carmen; José-Herrero, M Teresa San; López-Ropero, Ana M; Tenías Burillo, José María

    2014-01-01

    To estimate in patients awaiting cataract surgery the concordance and interchangeability of axial eye length measurements performed with the aid of various biometric methods (optical or ultrasonic) by different operators (nurses) at different times during the period prior to surgery. We selected 182 consecutive eyes from 91 patients.Ocular axial length was measured with the aid of 2 methods (IOLMaster® and Ocuscan®) by 9 randomly allocated technicians at 2 different times during the waiting period. The concordance between measurements was evaluated by means of the intraclass correlation coefficient (ICC); the interchangeability of the results was assessed with Bland Altman plots and Passing and Bablok regression. The measurements were consistent between biometric methods (ICC 0.975, 95% confidence interval [CI] 0.968 to 0.980) and measurement dates (ICC 0.996, 95% CI 0.995 to 0.997). Interobserver agreement was more heterogeneous (ICC range 0.844 to 0.998). No systematic errors were observed among the various biometric methods and measurement dates. Because measurement of axial length in phakic patients may be technician-dependent, the technician's experience should be noted in the protocols of ophthalmology services.

  13. Absolute Bunch Length Measurements by Incoherent Radiation Fluctuation Analysis

    International Nuclear Information System (INIS)

    Sannibale, F.; Stupakov, G.V.; Zolotorev, M.S.; Filippetto, D.; Jagerhofer, L.

    2009-01-01

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  14. Effects of diffraction and target finite size on coherent transition radiation spectra in bunch length measurements

    Energy Technology Data Exchange (ETDEWEB)

    Castellano, M.; Cianchi, A.; Verzilov, V.A. [Istituto Nazionale di Fisica Nucleare, Frascati, RM (Italy). Laboratori Nazionali di Frascati; Orlandi, G. [Istituto Nazionale di Fisica Nucleare, Rome (Italy)]|[Rome Univ., Tor Vergata, Rome (Italy)

    1999-07-01

    Effects of diffraction and the size of the target on TR in the context of CTR-based bunch length measurements are studied on the basis of Kirchhoff diffraction theory. Spectra of TR from the finite-size target for several schemes of measurements are calculated in the far-infrared region showing strong distortion at low frequencies. Influence of the effect on the accuracy of bunch length measurements is estimated.

  15. Effect of operational cycle time length on nitrogen removal in an alternating oxidation ditch system.

    Science.gov (United States)

    Mantziaras, I D; Stamou, A; Katsiri, A

    2011-06-01

    This paper refers to nitrogen removal optimization of an alternating oxidation ditch system through the use of a mathematical model and pilot testing. The pilot system where measurements have been made has a total volume of 120 m(3) and consists of two ditches operating in four phases during one cycle and performs carbon oxidation, nitrification, denitrification and settling. The mathematical model consists of one-dimensional mass balance (convection-dispersion) equations based on the IAWPRC ASM 1 model. After the calibration and verification of the model, simulation system performance was made. Optimization is achieved by testing operational cycles and phases with different time lengths. The limits of EU directive 91/271 for nitrogen removal have been used for comparison. The findings show that operational cycles with smaller time lengths can achieve higher nitrogen removals and that an "equilibrium" between phase time percentages in the whole cycle, for a given inflow, must be achieved.

  16. Realization of the Zone Length Measurement during Zone Refining Process via Implementation of an Infrared Camera

    Directory of Open Access Journals (Sweden)

    Danilo C. Curtolo

    2018-05-01

    Full Text Available Zone refining, as the currently most common industrial process to attain ultrapure metals, is influenced by a variety of factors. One of these parameters, the so-called “zone length”, affects not only the ultimate concentration distribution of impurities, but also the rate at which this distribution is approached. This important parameter has however neither been investigated experimentally, nor ever varied for the purpose of optimization. This lack of detections may be due to the difficult temperature measurement of a moving molten area in a vacuum system, of which the zone refining methodology is comprised. Up to now, numerical simulation as a combination of complex mathematical calculations, as well as many assumptions has been the only way to reveal it. This paper aims to propose an experimental method to accurately measure the molten zone length and to extract helpful information on the thermal gradient, temperature profile and real growth rate in the zone refining of an exemplary metal, in this case aluminum. This thermographic method is based on the measurement of the molten surface temperature via an infrared camera, as well as further data analysis through the mathematical software MATLAB. The obtained results show great correlation with the visual observations of zone length and provide helpful information to determine the thermal gradient and real growth rate during the whole process. The investigations in this paper approved the application of an infrared camera for this purpose as a promising technique to automatically control the zone length during a zone refining process.

  17. discouraged by queue length

    Directory of Open Access Journals (Sweden)

    P. R. Parthasarathy

    2001-01-01

    Full Text Available The transient solution is obtained analytically using continued fractions for a state-dependent birth-death queue in which potential customers are discouraged by the queue length. This queueing system is then compared with the well-known infinite server queueing system which has the same steady state solution as the model under consideration, whereas their transient solutions are different. A natural measure of speed of convergence of the mean number in the system to its stationarity is also computed.

  18. An experimental verification of the compensation of length change of line scales caused by ambient air pressure

    International Nuclear Information System (INIS)

    Takahashi, Akira; Miwa, Nobuharu

    2010-01-01

    Line scales are used as a working standard of length for the calibration of optical measuring instruments such as profile projectors, measuring microscopes and video measuring systems. The authors have developed a one-dimensional calibration system for line scales to obtain a lower uncertainty of measurement. The scale calibration system, named Standard Scale Calibrator SSC-05, employs a vacuum interferometer system for length measurement, a 633 nm iodine-stabilized He–Ne laser to calibrate the oscillating frequency of the interferometer laser light source and an Abbe's error compensation structure. To reduce the uncertainty of measurement, the uncertainty factors of the line scale and ambient conditions should not be neglected. Using the length calibration system, the expansion and contraction of a line scale due to changes in ambient air pressure were observed and the measured scale length was corrected into the length under standard atmospheric pressure, 1013.25 hPa. Utilizing a natural rapid change in the air pressure caused by a tropical storm (typhoon), we carried out an experiment on the length measurement of a 1000 mm long line scale made of glass ceramic with a low coefficient of thermal expansion. Using a compensation formula for the length change caused by changes in ambient air pressure, the length change of the 1000 mm long line scale was compensated with a standard deviation of less than 1 nm

  19. Accuracy of Jump-Mat Systems for Measuring Jump Height.

    Science.gov (United States)

    Pueo, Basilio; Lipinska, Patrycja; Jiménez-Olmedo, José M; Zmijewski, Piotr; Hopkins, Will G

    2017-08-01

    Vertical-jump tests are commonly used to evaluate lower-limb power of athletes and nonathletes. Several types of equipment are available for this purpose. To compare the error of measurement of 2 jump-mat systems (Chronojump-Boscosystem and Globus Ergo Tester) with that of a motion-capture system as a criterion and to determine the modifying effect of foot length on jump height. Thirty-one young adult men alternated 4 countermovement jumps with 4 squat jumps. Mean jump height and standard deviations representing technical error of measurement arising from each device and variability arising from the subjects themselves were estimated with a novel mixed model and evaluated via standardization and magnitude-based inference. The jump-mat systems produced nearly identical measures of jump height (differences in means and in technical errors of measurement ≤1 mm). Countermovement and squat-jump height were both 13.6 cm higher with motion capture (90% confidence limits ±0.3 cm), but this very large difference was reduced to small unclear differences when adjusted to a foot length of zero. Variability in countermovement and squat-jump height arising from the subjects was small (1.1 and 1.5 cm, respectively, 90% confidence limits ±0.3 cm); technical error of motion capture was similar in magnitude (1.7 and 1.6 cm, ±0.3 and ±0.4 cm), and that of the jump mats was similar or smaller (1.2 and 0.3 cm, ±0.5 and ±0.9 cm). The jump-mat systems provide trustworthy measurements for monitoring changes in jump height. Foot length can explain the substantially higher jump height observed with motion capture.

  20. Distance Between the Malleoli and the GroundA New Clinical Method to Measure Leg-Length Discrepancy.

    Science.gov (United States)

    Aguilar, Estela Gomez; Domínguez, Águeda Gómez; Peña-Algaba, Carolina; Castillo-López, José M

    2017-03-01

    The aim of this work is to introduce a useful method for the clinical diagnosis of leg-length inequality: distance between the malleoli and the ground (DMG). A transversal observational study was performed on 17 patients with leg-length discrepancy. Leg-length inequality was determined with different clinical methods: with a tape measure in a supine position from the anterior superior iliac spine (ASIS) to the internal and external malleoli, as the difference between the iliac crests when standing (pelvimeter), and as asymmetry between ASISs (PALpation Meter [PALM]; A&D Medical Products Healthcare, San Jose, California). The Foot Posture Index (FPI) and the navicular drop test were also used. The DMG with Perthes rule (perpendicular to the foot when standing), the distance between the internal malleolus and the ground (DIMG), and the distance between the external malleolus and the ground were designed by the authors. The DIMG is directly related to the traditional ASIS-external malleolus measurement (P = .003), the FPI (P = .010), and the navicular drop test (P DMG) is useful for diagnosing leg-length discrepancy and is related to the ASIS-external malleolus measurement. The DIMG is significantly inversely proportional to the degree of pronation according to the FPI. Conversely, determination of leg-length discrepancy with a tape measure from the ASIS to the malleoli cannot be performed interchangeably at the level of the internal or external malleolus.

  1. Measurements of Turbulent Flame Speed and Integral Length Scales in a Lean Stationary Premixed Flame

    OpenAIRE

    Klingmann, Jens; Johansson, Bengt

    1998-01-01

    Turbulent premixed natural gas - air flame velocities have been measured in a stationary axi-symmetric burner using LDA. The flame was stabilized by letting the flow retard toward a stagnation plate downstream of the burner exit. Turbulence was generated by letting the flow pass through a plate with drilled holes. Three different hole diameters were used, 3, 6 and 10 mm, in order to achieve different turbulent length scales. Turbulent integral length scales were measured using two-point LD...

  2. Comparison of Echo 7 field line length measurements to magnetospheric model predictions

    International Nuclear Information System (INIS)

    Nemzek, R.J.; Winckler, J.R.; Malcolm, P.R.

    1992-01-01

    The Echo 7 sounding rocket experiment injected electron beams on central tail field lines near L = 6.5. Numerous injections returned to the payload as conjugate echoes after mirroring in the southern hemisphere. The authors compare field line lengths calculated from measured conjugate echo bounce times and energies to predictions made by integrating electron trajectories through various magnetospheric models: the Olson-Pfitzer Quiet and Dynamic models and the Tsyganenko-Usmanov model. Although Kp at launch was 3-, quiet time magnetic models est fit the echo measurements. Geosynchronous satellite magnetometer measurements near the Echo 7 field lies during the flight were best modeled by the Olson-Pfitzer Dynamic Model and the Tsyganenko-Usmanov model for Kp = 3. The discrepancy between the models that best fit the Echo 7 data and those that fit the satellite data was most likely due to uncertainties in the small-scale configuration of the magnetospheric models. The field line length measured by the conjugate echoes showed some temporal variation in the magnetic field, also indicated by the satellite magnetometers. This demonstrates the utility an Echo-style experiment could have in substorm studies

  3. Measuring telomere length for the early detection of precursor lesions of esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Lin, Shih-Wen; Wang, Guo-Qing; Wei, Wen-Qiang; Lu, Ning; Taylor, Philip R; Qiao, You-Lin; Dawsey, Sanford M; Abnet, Christian C; Freedman, Neal D; Murphy, Gwen; Risques, Rosana; Prunkard, Donna; Rabinovitch, Peter; Pan, Qin-Jing; Roth, Mark J

    2013-01-01

    Esophageal cancer is the sixth leading cause of cancer death worldwide; current early detection screening tests are inadequate. Esophageal balloon cytology successfully retrieves exfoliated and scraped superficial esophageal epithelial cells, but cytologic reading of these cells has poor sensitivity and specificity for detecting esophageal squamous dysplasia (ESD), the precursor lesion of esophageal squamous cell carcinoma (ESCC). Measuring telomere length, a marker for chromosomal instability, may improve the utility of balloon cytology for detecting ESD and early ESCC. We examined balloon cytology specimens from 89 asymptomatic cases of ESD (37 low-grade and 52 high-grade) and 92 age- and sex-matched normal controls from an esophageal cancer early detection screening study. All subjects also underwent endoscopy and biopsy, and ESD was diagnosed histopathologically. DNA was extracted from the balloon cytology cells, and telomere length was measured by quantitative PCR. A receiver operating characteristic (ROC) curve was plotted for telomere length as a diagnostic marker for high-grade dysplasia. Telomere lengths were comparable among the low- and high-grade dysplasia cases and controls, with means of 0.96, 0.96, and 0.92, respectively. The area under the ROC curve was 0.55 for telomere length as a diagnostic marker for high-grade dysplasia. Further adjustment for subject characteristics, including sex, age, smoking, drinking, hypertension, and body mass index did not improve the use of telomere length as a marker for ESD. Telomere length of esophageal balloon cytology cells was not associated with ESCC precursor lesions. Therefore, telomere length shows little promise as an early detection marker for ESCC in esophageal balloon samples

  4. Advanced Active-Magnetic-Bearing Thrust-Measurement System

    Science.gov (United States)

    Imlach, Joseph; Kasarda, Mary; Blumber, Eric

    2008-01-01

    -magnetic-bearing force-measurement systems is to calculate levitation forces on the basis of simple proportionalities between changes in those forces and changes in feedback-controlled currents applied to levitating electromagnetic coils. In the prior systems, the effects of gap lengths on fringing magnetic fields and the concomitant effects on magnetic forces were neglected. In the present system, the control subsystems of the active magnetic bearings are coupled with a computer-based automatic calibration system running special-purpose software wherein gap-length-dependent fringing factors are applied to current and magnetic-flux-based force equations and combined with a multipoint calibration method to obtain greater accuracy.

  5. Scattering length measurements from radiative pion capture and neutron-deuteron breakup

    International Nuclear Information System (INIS)

    Gibson, B.F.; Tornow, W.; Carman, T.S.

    1997-07-01

    The neutron-neutron and neutron-proton 1 S 0 scattering lengths a nn and a np , respectively, were determined simultaneously from the neutron-deuteron breakup reaction. Their comparison with the recommended values obtained from two body reactions gives a measure of the importance of three-nucleon force effects in the three-nucleon continuum. In order to check on the result obtained for a nn from the two-body π - -d capture reaction, a new measurement was performed at LANL. Preliminary results of the three experiments are given

  6. Natural Length Scales of Ecological Systems: Applications at Community and Ecosystem Levels

    Directory of Open Access Journals (Sweden)

    Craig R. Johnson

    2009-06-01

    Full Text Available The characteristic, or natural, length scales of a spatially dynamic ecological landscape are the spatial scales at which the deterministic trends in the dynamic are most sharply in focus. Given recent development of techniques to determine the characteristic length scales (CLSs of real ecological systems, I explore the potential for using CLSs to address three important and vexing issues in applied ecology, viz. (i determining the optimum scales to monitor ecological systems, (ii interpreting change in ecological communities, and (iii ascertaining connectivity between species in complex ecologies. In summarizing the concept of characteristic length scales as system-level scaling thresholds, I emphasize that the primary CLS is, by definition, the optimum scale at which to monitor a system if the objective is to observe its deterministic dynamics at a system level. Using several different spatially explicit individual-based models, I then explore predictions of the underlying theory of CLSs in the context of interpreting change and ascertaining connectivity among species in ecological systems. Analysis of these models support predictions that systems with strongly fluctuating community structure, but an otherwise stable long-term dynamic defined by a stationary attractor, indicate an invariant length scale irrespective of community structure at the time of analysis, and irrespective of the species analyzed. In contrast, if changes in the underlying dynamic are forcibly induced, the shift in dynamics is reflected by a change in the primary length scale. Thus, consideration of the magnitude of the CLS through time enables distinguishing between circumstances where there are temporal changes in community structure but not in the long-term dynamic, from that where changes in community structure reflect some kind of fundamental shift in dynamics. In this context, CLSs emerge as a diagnostic tool to identify phase shifts to alternative stable states

  7. Effects of tubing length and coupling method on hearing threshold and real-ear to coupler difference measures.

    Science.gov (United States)

    Gustafson, Samantha; Pittman, Andrea; Fanning, Robert

    2013-06-01

    This tutorial demonstrates the effects of tubing length and coupling type (i.e., foam tip or personal earmold) on hearing threshold and real-ear-to-coupler difference (RECD) measures. Hearing thresholds from 0.25 kHz through 8 kHz are reported at various tubing lengths for 28 normal-hearing adults between the ages of 22 and 31 years. RECD values are reported for 14 of the adults. All measures were made with an insert earphone coupled to a standard foam tip and with an insert earphone coupled to each participant's personal earmold. Threshold and RECD measures obtained with a personal earmold were significantly different from those obtained with a foam tip on repeated measures analyses of variance. One-sample t tests showed these differences to vary systematically with increasing tubing length, with the largest average differences (7-8 dB) occurring at 4 kHz. This systematic examination demonstrates the equal and opposite effects of tubing length on threshold and acoustic measures. Specifically, as tubing length increased, sound pressure level in the ear canal decreased, affecting both hearing thresholds and the real-ear portion of the RECDs. This demonstration shows that when the same coupling method is used to obtain the hearing thresholds and RECD, equal and accurate estimates of real-ear sound pressure level are obtained.

  8. CT measurements of torsion and length in the lower extremities

    International Nuclear Information System (INIS)

    Waidelich, H.A.; Strecker, W.; Schneider, E.

    1992-01-01

    Complex corrective osteotomies in the lower extremities require precise preoperative planning. Fifty patients who had suffered fractures of the lower limbs and had been treated by osteosynthetic or conservative methods were studied, using a GE 9800 Quick CT; accurate and reproducible measurements of the angles of torsion of the femur and tibia were obtained. Digital images were produced to standardise the planes of measurement and to measure the length of the limb. The most important clinical measurement is the intra-individual difference of the torsional angles. Amongst normals this is 4.3 ± 2.3deg in the femur and 6.1 ± 4.5deg in the tibia. Radiation exposure was measured by a LiF-thermoluminescence dosimeter on an Alderson phantom. Skin dose was 6.3 ± 1.2 mGy and gonadal dose for females was 2.5 ± 0.3 mGy and for males 0.7 ± 0.1 mGy. (orig./GDG) [de

  9. Anthropometric measurements of foot length and shape in children 2 to 7 years of age

    OpenAIRE

    Vrdoljak, Ozren; Kujundžić Tiljak, Mirjana; Čimić, Mislav

    2017-01-01

    Background and purpose: A child’s foot changes shape and proportions during growth so that it adapts to function. The purpose of this article is to determine foot length in children aged 2-7 years as a fundamental unit for measuring the growth of the foot, with which it will be able to compare other anthropometric measures of the foot. Determination of the shape of the foot and interpretation of the growth curve of the foot in length are important for standardization of the foot.Materials and...

  10. Air method measurements of apple vessel length distributions with improved apparatus and theory

    Science.gov (United States)

    Shabtal Cohen; John Bennink; Mel Tyree

    2003-01-01

    Studies showing that rootstock dwarfing potential is related to plant hydraulic conductance led to the hypothesis that xylem properties are also related. Vessel length distribution and other properties of apple wood from a series of varieties were measured using the 'air method' in order to test this hypothesis. Apparatus was built to measure and monitor...

  11. Spatial correlation length of normalized cone data in sand

    DEFF Research Database (Denmark)

    Firouzianbandpey, Sarah; Griffiths, D. V.; Ibsen, Lars Bo

    2014-01-01

    The main topic of this study is to assess the anisotropic spatial correlation lengths of a sand layer deposit based on cone penetration testing with pore pressure measurement (CPTu) data. Spatial correlation length can be an important factor in reliability analysis of geotechnical systems, yet it...

  12. Activity-dependent self-regulation of viscous length scales in biological systems

    Science.gov (United States)

    Nandi, Saroj Kumar

    2018-05-01

    The cellular cortex, which is a highly viscous thin cytoplasmic layer just below the cell membrane, controls the cell's mechanical properties, which can be characterized by a hydrodynamic length scale ℓ . Cells actively regulate ℓ via the activity of force-generating molecules, such as myosin II. Here we develop a general theory for such systems through a coarse-grained hydrodynamic approach including activity in the static description of the system providing an experimentally accessible parameter and elucidate the detailed mechanism of how a living system can actively self-regulate its hydrodynamic length scale, controlling the rigidity of the system. Remarkably, we find that ℓ , as a function of activity, behaves universally and roughly inversely proportional to the activity of the system. Our theory rationalizes a number of experimental findings on diverse systems, and comparison of our theory with existing experimental data shows good agreement.

  13. Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurments of diffuse light

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton; Steenbergen, Wiendelt

    2007-01-01

    The performance of a graded index multimode fiber optic low coherence Mach-Zehnder interferometer with phase modulation is analyzed. Investigated aspects were its ability to measure path length distributions and to perform path length resolved Doppler measurements of multiple scattered photons in a

  14. Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurements of diffuse light

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton G.; Steenbergen, Wiendelt

    2007-01-01

    The performance of a graded index multimode fiber optic low coherence Mach-Zehnder interferometer with phase modulation is analyzed. Investigated aspects were its ability to measure path length distributions and to perform path length resolved Doppler measurements of multiple scattered photons in a

  15. Measurement of the diffusion length of thermal neutrons in the beryllium oxide

    International Nuclear Information System (INIS)

    Koechlin, J.C.; Martelly, J.; Duggal, V.P.

    1955-01-01

    The diffusion length of thermal neutrons in the beryllium oxide has been obtained while studying the spatial distribution of the neutrons in a massive parallelepiped of this matter placed before the thermal column of the reactor core of Saclay. The mean density of the beryllium oxide (BeO) is 2,95 gr/cm 3 , the mean density of the massif is 2,92 gr/cm 3 . The value of the diffusion length, deducted of the done measures, is: L = 32,7 ± 0,5 cm (likely gap). Some remarks are formulated about the influence of the spectral distribution of the neutrons flux used. (authors) [fr

  16. Acoustic Measurement of the Length of Air-plasma Filament Induced by an Intense Femtosecond Laser Pulse

    Directory of Open Access Journals (Sweden)

    Wu Si-Qing

    2017-01-01

    Full Text Available The paper studies acoustic emission from air-plasma filament induced by a strong femtosecond laser pulse. Acoustic signal is detected with a sensitive directional microphone. Acoustic measurement provides a new method to determine the length of a filament. Compared with other methods, acoustic measurement is simpler, more sensitive, and with higher spatial resolution. Information of filament length is experimentally acquired through measuring acoustic pressure at different position of filament. On the basis of the relationship between acoustic signal and free-electron density in filament, profile of free-electron density is demonstrated

  17. Assessing Leg length Discrepancy Using a Biplane Low Dose Imaging System. A Comparative Diagnostic Study

    DEFF Research Database (Denmark)

    Jensen, Janni; Mussmann, Bo Redder; Torfing, Trine

    study was to evaluate the diagnostic accuracy of leg length (LL) measurements performed on low dose pre-view images acquired using a new bi-planar imaging system. The administered radiation dose from the pre-view image is approximately 20,17μGycm2 vs. 2670μGycm2 when acquiring the diagnostic image.......84) for the tibial measurements and the mean difference for total LLD was 0.01cm (p=0.92) and 0.03cm (p=0.73). All ICC calculations were >.99 indicating excellent inter- and intra-rater reliability. Conclusion. The results strongly imply that LL measurements performed on pre-view images acquired with a new bi...

  18. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    International Nuclear Information System (INIS)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F.

    2015-01-01

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length

  19. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length.

    Science.gov (United States)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F

    2015-09-01

    Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as -0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31 μl/min among four wild-type rats. The authors' measured flow rates were consistent with results in the literature. By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  20. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Jiao, Shuliang [Department of Biomedical Engineering, Florida International University, Miami, Florida 33174 (United States); Zhang, Hao F., E-mail: hfzhang@northwestern.edu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 and Department of Ophthalmology, Northwestern University, Chicago, Illinois 60611 (United States)

    2015-09-15

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  1. A 7MeV S-Band 2998MHz Variable Pulse Length Linear Accelerator System

    CERN Document Server

    Hernandez, Michael; Mishin, Andrey V; Saverskiy, Aleksandr J; Skowbo, Dave; Smith, Richard

    2005-01-01

    American Science and Engineering High Energy Systems Division (AS&E HESD) has designed and commissioned a variable pulse length 7 MeV electron accelerator system. The system is capable of delivering a 7 MeV electron beam with a pulse length of 10 nS FWHM and a peak current of 1 ampere. The system can also produce electron pulses with lengths of 20, 50, 100, 200, 400 nS and 3 uS FWHM with corresponding lower peak currents. The accelerator system consists of a gridded electron gun, focusing coil, an electrostatic deflector system, Helmholtz coils, a standing wave side coupled S-band linac, a 2.6 MW peak power magnetron, an RF circulator, a fast toroid, vacuum system and a PLC/PC control system. The system has been operated at repetition rates up to 250pps. The design, simulations and experimental results from the accelerator system are presented in this paper.

  2. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    International Nuclear Information System (INIS)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung; Kim, Ji Eun

    2013-01-01

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm 3 ). Anthropometric indices including height (cm), weight (kg) and body mass index (m 2 /kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  3. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Ji Eun [Biostatistics Collaboration Unit, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2013-08-15

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm{sup 3}). Anthropometric indices including height (cm), weight (kg) and body mass index (m{sup 2}/kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  4. Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement.

    Science.gov (United States)

    Liu, Chengyu; Griffiths, Clive; Murray, Alan; Zheng, Dingchang

    2016-06-01

    This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant.

  5. The validity of cone-beam computed tomography in measuring root canal length using a gold standard

    NARCIS (Netherlands)

    Liang, Y.H.; Jiang, L.; Chen, C.; Gao, X.J.; Wesselink, P.R.; Wu, M.K.; Shemesh, H.

    2013-01-01

    Introduction The distance between a coronal reference point and the major apical foramen is important for working length determination. The aim of this in vitro study was to determine the accuracy of root canal length measurements performed with cone-beam computed tomographic (CBCT) scans using a

  6. Scattering length measurements from radiative pion capture and neutron-deuteron breakup

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W.; Chen, Q. [Duke Univ., Durham, NC (United States). Dept. of Physics; Carman, T.S. [Lawrence Livermore National Lab., CA (United States). Program for Climate Model Diagnosis and Intercomparison] [and others

    1998-03-02

    The neutron-neutron and neutron-proton {sup 1}S{sub 0} scattering lengths a{sub nn} and a{sub np}, respectively, were determined simultaneously from the neutron-deuteron breakup reaction. Their comparison with the recommended values obtained from ``two-body`` reactions gives a measure of the importance of three-nucleon force effects in the three-nucleon continuum. In order to check on the result obtained for a{sub nn} from the ``two-body`` {pi}{sup -}-d capture reaction, a new measurement was performed at LANL. Preliminary results of the three experiments are given. (orig.). 5 refs.

  7. The accuracy of three-dimensional fused deposition modeling (FDM) compared with three-dimensional CT-Scans on the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle

    Science.gov (United States)

    Savitri, I. T.; Badri, C.; Sulistyani, L. D.

    2017-08-01

    Presurgical treatment planning plays an important role in the reconstruction and correction of defects in the craniomaxillofacial region. The advance of solid freeform fabrication techniques has significantly improved the process of preparing a biomodel using computer-aided design and data from medical imaging. Many factors are implicated in the accuracy of the 3D model. To determine the accuracy of three-dimensional fused deposition modeling (FDM) models compared with three-dimensional CT scans in the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle. Eight 3D models were produced from the CT scan data (DICOM file) of eight patients at the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Indonesia, Cipto Mangunkusumo Hospital. Three measurements were done three times by two examiners. The measurements of the 3D CT scans were made using OsiriX software, while the measurements of the 3D models were made using a digital caliper and goniometry. The measurement results were then compared. There is no significant difference between the measurements of the mandibular ramus vertical length, gonion-menton length, and gonial angle using 3D CT scans and FDM 3D models. FDM 3D models are considered accurate and are acceptable for clinical applications in dental and craniomaxillofacial surgery.

  8. The value of Sonographic measurement of cervical length and fetal fibronectin testing in predicting preterm delivery

    Directory of Open Access Journals (Sweden)

    Zeki Salar

    2007-03-01

    Full Text Available OBJECTIVE: The aim of this study was to determine whether the combination of both fetal fibronectin and sonographic measurement of cervical length in women with preterm labor provides a better prediction than the individual tests alone.\tMETHODS: We examined 40 women with singleton pregnancies presenting at 24–35 (median 31 weeks of gestation with regular and painful uterine contractions, intact membranes and cervical dilatation of less than 3 cm. On admission to the hospital, fetal fibronectin positivity in cervicovaginal secretions was determined and transvaginal sonographic measurement of cervical length was carried out. The primary outcome measure was delivery within 14 days of presentation.\tRESULTS: Total of 40 eligible women at a mean gestational age of 28,3±4,8 weeks were enrolled from a population of 196 subjects screened. The overall prevalence of preterm delivery CONCLUSIONS: Combined the assessment of fetal fibronectin in cervico-vaginal secretions and the sonographic cervical length measurement improve the prediction of preterm delivery within 14 days in women with threatened preterm labor

  9. Analytical model and error analysis of arbitrary phasing technique for bunch length measurement

    Science.gov (United States)

    Chen, Qushan; Qin, Bin; Chen, Wei; Fan, Kuanjun; Pei, Yuanji

    2018-05-01

    An analytical model of an RF phasing method using arbitrary phase scanning for bunch length measurement is reported. We set up a statistical model instead of a linear chirp approximation to analyze the energy modulation process. It is found that, assuming a short bunch (σφ / 2 π → 0) and small relative energy spread (σγ /γr → 0), the energy spread (Y =σγ 2) at the exit of the traveling wave linac has a parabolic relationship with the cosine value of the injection phase (X = cosφr|z=0), i.e., Y = AX2 + BX + C. Analogous to quadrupole strength scanning for emittance measurement, this phase scanning method can be used to obtain the bunch length by measuring the energy spread at different injection phases. The injection phases can be randomly chosen, which is significantly different from the commonly used zero-phasing method. Further, the systematic error of the reported method, such as the influence of the space charge effect, is analyzed. This technique will be especially useful at low energies when the beam quality is dramatically degraded and is hard to measure using the zero-phasing method.

  10. Assessing Children's Understanding of Length Measurement: A Focus on Three Key Concepts

    Science.gov (United States)

    Bush, Heidi

    2009-01-01

    In this article, the author presents three different tasks that can be used to assess students' understanding of the concept of length. Three important measurement concepts for students to understand are transitive reasoning, use of identical units, and iteration. In any teaching and learning process it is important to acknowledge students'…

  11. A noncontact laser system for measuring soil surface topography

    International Nuclear Information System (INIS)

    Huang, C.; White, I.; Thwaite, E.G.; Bendeli, A.

    1988-01-01

    Soil surface topography profoundly influences runoff hydrodynamics, soil erosion, and surface retention of water. Here we describe an optical noncontact system for measuring soil surface topography. Soil elevation is measured by projecting a laser beam onto the surface and detecting the position of the interception point. The optical axis of the detection system is oriented at a small angle to the incident beam. A low-power HeNe (Helium-Neon) laser is used as the laser source, a photodiode array is used as the laser image detector and an ordinary 35-mm single lens reflex camera provides the optical system to focus the laser image onto the diode array. A wide spectrum of measurement ranges (R) and resolutions are selectable, from 1 mm to 1 m. These are determined by the laser-camera distance and angle, the focal length of the lens, and the sensing length of the diode array and the number of elements (N) contained in the array. The resolution of the system is approximately R/2N. We show for the system used here that this resolution is approximately 0.2%. In the configuration selected, elevation changes of 0.16 mm could be detected over a surface elevation range of 87 mm. The sampling rate of the system is 1000 Hz, which permits soil surfaces to be measured at speeds of up to 1 m s −1 with measurements taken at 1-mm spacing. Measurements of individual raindrop impacts on the soil and of soil surfaces before and after rain show the versatility of the laser surface profiler, which has applications in studies of erosion processes, surface storage and soil trafficability

  12. Path-length-resolved measurements of multiple scattered photons in static and dynamic turbid media using phase-modulated low-coherence interferometry

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton G.; Steenbergen, Wiendelt

    2007-01-01

    In optical Doppler measurements, the path length of the light is unknown. To facilitate quantitative measurements, we develop a phase-modulated Mach-Zehnder interferometer with separate fibers for illumination and detection. With this setup, path-length-resolved dynamic light scattering measurements

  13. Photon path length distributions for cloudy skies – oxygen A-Band measurements and model calculations

    Directory of Open Access Journals (Sweden)

    O. Funk

    2003-03-01

    Full Text Available This paper addresses the statistics underlying cloudy sky radiative transfer (RT by inspection of the distribution of the path lengths of solar photons. Recent studies indicate that this approach is promising, since it might reveal characteristics about the diffusion process underlying atmospheric radiative transfer (Pfeilsticker, 1999. Moreover, it uses an observable that is directly related to the atmospheric absorption and, therefore, of climatic relevance. However, these studies are based largely on the accuracy of the measurement of the photon path length distribution (PPD. This paper presents a refined analysis method based on high resolution spectroscopy of the oxygen A-band. The method is validated by Monte Carlo simulation atmospheric spectra. Additionally, a new method to measure the effective optical thickness of cloud layers, based on fitting the measured differential transmissions with a 1-dimensional (discrete ordinate RT model, is presented. These methods are applied to measurements conducted during the cloud radar inter-comparison campaign CLARE’98, which supplied detailed cloud structure information, required for the further analysis. For some exemplary cases, measured path length distributions and optical thicknesses are presented and backed by detailed RT model calculations. For all cases, reasonable PPDs can be retrieved and the effects of the vertical cloud structure are found. The inferred cloud optical thicknesses are in agreement with liquid water path measurements. Key words. Meteorology and atmospheric dynamics (radiative processes; instruments and techniques

  14. Photon path length distributions for cloudy skies – oxygen A-Band measurements and model calculations

    Directory of Open Access Journals (Sweden)

    O. Funk

    Full Text Available This paper addresses the statistics underlying cloudy sky radiative transfer (RT by inspection of the distribution of the path lengths of solar photons. Recent studies indicate that this approach is promising, since it might reveal characteristics about the diffusion process underlying atmospheric radiative transfer (Pfeilsticker, 1999. Moreover, it uses an observable that is directly related to the atmospheric absorption and, therefore, of climatic relevance. However, these studies are based largely on the accuracy of the measurement of the photon path length distribution (PPD. This paper presents a refined analysis method based on high resolution spectroscopy of the oxygen A-band. The method is validated by Monte Carlo simulation atmospheric spectra. Additionally, a new method to measure the effective optical thickness of cloud layers, based on fitting the measured differential transmissions with a 1-dimensional (discrete ordinate RT model, is presented. These methods are applied to measurements conducted during the cloud radar inter-comparison campaign CLARE’98, which supplied detailed cloud structure information, required for the further analysis. For some exemplary cases, measured path length distributions and optical thicknesses are presented and backed by detailed RT model calculations. For all cases, reasonable PPDs can be retrieved and the effects of the vertical cloud structure are found. The inferred cloud optical thicknesses are in agreement with liquid water path measurements.

    Key words. Meteorology and atmospheric dynamics (radiative processes; instruments and techniques

  15. The measurement of the optical cavity length for the infrared free electron laser

    International Nuclear Information System (INIS)

    Curtis, C.J.; Dahlberg, J.C.; Oren, W.A.; Tremblay, K.J.

    1999-01-01

    One of the final tasks involved in the alignment of the newly constructed Free Electron Laser at the Thomas Jefferson National Accelerator Facility was to accurately measure the length between two mirrors which make up the optical cavity. This presentation examines the survey techniques and equipment assembled in order to complete these measurements, together with the possible sources of error, and the accuracy achieved. (authors)

  16. Measuring the attenuation length of water in the CHIPS-M water Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Amat, F.; Bizouard, P. [Aix Marseille University Saint-Jerome, 13013 Marseille (France); Bryant, J. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Carroll, T.J.; Rijck, S. De [Department of Physics, University of Texas at Austin, Austin, TX 78712 (United States); Germani, S. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Joyce, T. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Kriesten, B. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Marshak, M.; Meier, J. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Nelson, J.K. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Perch, A.J.; Pfützner, M.M. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Salazar, R. [Department of Physics, University of Texas at Austin, Austin, TX 78712 (United States); Thomas, J., E-mail: jennifer.thomas@ucl.ac.uk [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Trokan-Tenorio, J. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Vahle, P. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Wade, R. [Avenir Consulting, Abingdon, Oxfordshire (United Kingdom); Wendt, C. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Whitehead, L.H. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); and others

    2017-02-01

    The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2 m vertical column filled with this water, was used to study the transmission of 405 nm laser light. Results consistent with attenuation lengths of up to 100 m were observed for this wavelength with filtration and UV sterilization alone.

  17. Tubing length for long-term oxygen therapy.

    Science.gov (United States)

    Aguiar, Carolina; Davidson, Josy; Carvalho, Andréa K; Iamonti, Vinícius C; Cortopassi, Felipe; Nascimento, Oliver A; Jardim, José R

    2015-02-01

    Most patients on long-term oxygen therapy use stationary oxygen delivery systems. It is not uncommon for guidelines to instruct patients to use tubing lengths no longer than 19.68 ft (6 m) when using an oxygen concentrator and 49.21 ft (15 m) when using cylinders. However, these concepts are not based on sufficient evidence. Thus, our objective was to evaluate whether a 98.42-ft (30-m) tubing length affects oxygen flow and FIO2 delivery from 1 cylinder and 2 oxygen concentrators. The 3 oxygen delivery systems were randomly selected, and 1, 3, and 5 L/min flows and FIO2 were measured 5 times at each flow at the proximal and distal outlets of the tubing by a gas-flow analyzer. Paired Student t test was used to analyze the difference between flows and FIO2 at proximal and distal outlets of tubing length. A total of 45 flows were measured between proximal and distal outlets of the 98.42-ft (30-m) tubing. Flows were similar for 1 and 3 L/min, but distal flow was higher than proximal flow at 5 L/min (5.57×5.14 L/min, Ptubing at flows 1, 3, and 5 L/min, but the mean difference between measurements was less than 1%. Tubing length of 98.42 ft (30 m) may be used by patients for home delivery oxygen with flows up to 5 L/min, as there were no important changes in flows or FIO2. Copyright © 2015 by Daedalus Enterprises.

  18. Predicted singers' vocal fold lengths and voice classification-a study of x-ray morphological measures.

    Science.gov (United States)

    Roers, Friederike; Mürbe, Dirk; Sundberg, Johan

    2009-07-01

    Students admitted to the solo singing education at the University of Music Dresden, Germany have been submitted to a detailed physical examination of a variety of factors with relevance to voice function since 1959. In the years 1959-1991, this scheme of examinations included X-ray profiles of the singers' vocal tracts. This material of 132 X-rays of voice professionals was used to investigate different laryngeal morphological measures and their relation to vocal fold length. Further, the study aimed to investigate if there are consistent anatomical differences between singers of different voice classifications. The study design used was a retrospective analysis. Vocal fold length could be measured in 29 of these singer subjects directly. These data showed a strong correlation with the anterior-posterior diameter of the subglottis and the trachea as well as with the distance from the anterior contour of the thyroid cartilage to the anterior contour of the spine. These relations were used in an attempt to predict the 132 singers' vocal fold lengths. The results revealed a clear covariation between predicted vocal fold length and voice classification. Anterior-posterior subglottic-tracheal diameter yielded mean vocal fold lengths of 14.9, 16.0, 16.6, 18.4, 19.5, and 20.9mm for sopranos, mezzo-sopranos, altos, tenors, baritones, and basses, respectively. The data support the assumption that there are consistent anatomical laryngeal differences between singers of different voice classifications, which are of relevance to pitch range and timbre of the voice.

  19. Contribution of BeiDou satellite system for long baseline GNSS measurement in Indonesia

    Science.gov (United States)

    Gumilar, I.; Bramanto, B.; Kuntjoro, W.; Abidin, H. Z.; Trihantoro, N. F.

    2018-05-01

    The demand for more precise positioning method using GNSS (Global Navigation Satellite System) in Indonesia continue to rise. The accuracy of GNSS positioning depends on the length of baseline and the distribution of observed satellites. BeiDou Navigation Satellite System (BDS) is a positioning system owned by China that operating in Asia-Pacific region, including Indonesia. This research aims to find out the contribution of BDS in increasing the accuracy of long baseline static positioning in Indonesia. The contributions are assessed by comparing the accuracy of measurement using only GPS (Global Positioning System) and measurement using the combination of GPS and BDS. The data used is 5 days of GPS and BDS measurement data for baseline with 120 km in length. The software used is open-source RTKLIB and commercial software Compass Solution. This research will explain in detail the contribution of BDS to the accuracy of position in long baseline static GNSS measurement.

  20. Diffusion length measurements in bulk and epitaxially grown 3-5 semiconductors using charge collection microscopy

    Science.gov (United States)

    Leon, R. P.

    1987-01-01

    Diffusion lengths and surface recombination velocities were measured in GaAs diodes and InP finished solar cells. The basic techniques used was charge collection microscopy also known as electron beam induced current (EBIC). The normalized currents and distances from the pn junction were read directly from the calibrated curves obtained while using the line scan mode in an SEM. These values were then equated to integral and infinite series expressions resulting from the solution of the diffusion equation with both extended generation and point generation functions. This expands previous work by examining both thin and thick samples. The surface recombination velocity was either treated as an unknown in a system of two equations, or measured directly using low e(-) beam accelerating voltages. These techniques give accurate results by accounting for the effects of surface recombination and the finite size of the generation volume.

  1. A queueing system with queue length dependent service times, with applications to cell discarding in ATM networks

    Directory of Open Access Journals (Sweden)

    Doo Il Choi

    1999-01-01

    Full Text Available A queueing system (M/G1,G2/1/K is considered in which the service time of a customer entering service depends on whether the queue length, N(t, is above or below a threshold L. The arrival process is Poisson, and the general service times S1 and S2 depend on whether the queue length at the time service is initiated is systems. Asymptotic approximations of the solutions are given, which yield simple formulas for performance measures such as loss rates and tail probabilities. The numerical accuracy of the asymptotic results is tested.

  2. Remote-controlled flexible pose measurement system and method for a moving target in wind tunnel

    Directory of Open Access Journals (Sweden)

    Wei LIU

    2018-01-01

    Full Text Available The measurement of position and attitude parameters for the isolated target from a high-speed aircraft is a great challenge in the field of wind tunnel simulation technology. This paper proposes a remote-controlled flexible pose measurement system in wind tunnel conditions for the separation of a target from an aircraft. The position and attitude parameters of a moving object are obtained by utilizing a single camera with a focal length and camera orientation that can be changed based on different measurement conditions. Using this proposed system and method, both the flexibility and efficiency of the pose measurement system can be enhanced in wind tunnel conditions to meet the measurement requirements of different objects and experiments, which is also useful for the development of an intelligent position and attitude measurement system. The position and the focal length of the camera also can be controlled remotely during measurements to enlarge both the vertical and horizontal measurement range of this system. Experiments are conducted in the laboratory to measure the position and attitude of moving objects with high flexibility and efficiency, and the measurement precision of the measurement system is also verified through experiments.

  3. Universality in few-body systems with large scattering length

    International Nuclear Information System (INIS)

    Hammer, H.-W.

    2005-01-01

    Effective Field Theory (EFT) provides a powerful framework that exploits a separation of scales in physical systems to perform systematically improvable, model-independent calculations. Particularly interesting are few-body systems with short-range interactions and large two-body scattering length. Such systems display remarkable universal features. In systems with more than two particles, a three-body force with limit cycle behavior is required for consistent renormalization already at leading order. We will review this EFT and some of its applications in the physics of cold atoms and nuclear physics. In particular, we will discuss the possibility of an infrared limit cycle in QCD. Recent extensions of the EFT approach to the four-body system and N-boson droplets in two spatial dimensions will also be addressed

  4. Crack Length Detection by Digital Image Processing

    DEFF Research Database (Denmark)

    Lyngbye, Janus; Brincker, Rune

    1990-01-01

    It is described how digital image processing is used for measuring the length of fatigue cracks. The system is installed in a Personal Computer equipped with image processing hardware and performs automated measuring on plane metal specimens used in fatigue testing. Normally one can not achieve...... a resolution better then that of the image processing equipment. To overcome this problem an extrapolation technique is used resulting in a better resolution. The system was tested on a specimen loaded with different loads. The error σa was less than 0.031 mm, which is of the same size as human measuring...

  5. [A focused sound field measurement system by LabVIEW].

    Science.gov (United States)

    Jiang, Zhan; Bai, Jingfeng; Yu, Ying

    2014-05-01

    In this paper, according to the requirement of the focused sound field measurement, a focused sound field measurement system was established based on the LabVIEW virtual instrument platform. The system can automatically search the focus position of the sound field, and adjust the scanning path according to the size of the focal region. Three-dimensional sound field scanning time reduced from 888 hours in uniform step to 9.25 hours in variable step. The efficiency of the focused sound field measurement was improved. There is a certain deviation between measurement results and theoretical calculation results. Focal plane--6 dB width difference rate was 3.691%, the beam axis--6 dB length differences rate was 12.937%.

  6. Photoluminescence decay lifetime measurements of hemicyanine derivatives of different alkyl chain lengths

    International Nuclear Information System (INIS)

    Shim, Taekyu; Lee, Myounghee; Kim, Sungho; Sung, Jaeho; Rhee, Bum Ku; Kim, Doseok; Kim, Hyunsung; Yoon, Kyung Byung

    2004-01-01

    The fluorescence upconversion setup for the detection of photoluminescence (PL) decay lifetime with subpicosecond time resolution was constructed, and the photoluminescence phenomena of several hemicyanine dyes with alkyl chains of different chain lengths tethered to the N atom of the pyridine moiety (HC-n, n=6, 15, 22) in methanol were investigated. The average decay lifetimes of the solutions determined from the measured data by multi-order exponential decay curve fitting were ∼27 ps at the PL peak wavelength. It was found that the PL decay properties did not depend on the alkyl chain length in the molecule, implying that the twist of the alkylpyridinium ring of the molecule is not possible as a nonfluorescing relaxation pathway. The time-dependent PL spectra constructed from the PL lifetime data showed the dynamic Stokes shift of ∼1000 cm -1

  7. Sperm length, sperm storage and mating system characteristics in bumblebees

    DEFF Research Database (Denmark)

    Baer, Boris; Schmid-Hempel, Paul; Høeg, Jens Thorvald

    2003-01-01

    -term storage of sperm, using three bumblebee species with different mating systems as models. We show that individual males produce only one size-class of sperm, but that sperm length is highly variable among brothers, among unrelated conspecific males, and among males of different species. Males of Bombus...

  8. Prediction of the mixing length in effluent transport in rivers

    International Nuclear Information System (INIS)

    Szpilowski, S.

    1983-01-01

    Studies have been performed on estimating the transverse mixing length of effluents discharged into rivers. The proposed method is based on measured values of the dispersion coefficient. Field investigations were carried out in the River Vistula in the Warsaw area using radiotracer methods. The procedure can be used for predicting the mixing length in designing sewage systems. (author)

  9. Determination of the paraxial focal length using Zernike polynomials over different apertures

    Science.gov (United States)

    Binkele, Tobias; Hilbig, David; Henning, Thomas; Fleischmann, Friedrich

    2017-02-01

    The paraxial focal length is still the most important parameter in the design of a lens. As presented at the SPIE Optics + Photonics 2016, the measured focal length is a function of the aperture. The paraxial focal length can be found when the aperture approaches zero. In this work, we investigate the dependency of the Zernike polynomials on the aperture size with respect to 3D space. By this, conventional wavefront measurement systems that apply Zernike polynomial fitting (e.g. Shack-Hartmann-Sensor) can be used to determine the paraxial focal length, too. Since the Zernike polynomials are orthogonal over a unit circle, the aperture used in the measurement has to be normalized. By shrinking the aperture and keeping up with the normalization, the Zernike coefficients change. The relation between these changes and the paraxial focal length are investigated. The dependency of the focal length on the aperture size is derived analytically and evaluated by simulation and measurement of a strong focusing lens. The measurements are performed using experimental ray tracing and a Shack-Hartmann-Sensor. Using experimental ray tracing for the measurements, the aperture can be chosen easily. Regarding the measurements with the Shack-Hartmann- Sensor, the aperture size is fixed. Thus, the Zernike polynomials have to be adapted to use different aperture sizes by the proposed method. By doing this, the paraxial focal length can be determined from the measurements in both cases.

  10. Non-dispersive method for measuring longitudinal neutron coherence length using high frequency cold neutron pulser

    International Nuclear Information System (INIS)

    Kawai, T.; Tasaki, S.; Ebisawa, T.; Hino, M.; Yamazaki, D.; Achiwa, N.

    1999-01-01

    Complete text of publication follows. A non-dispersive method is proposed for measuring the longitudinal coherence length of a neutron using a high frequency cold neutron pulser (hf-CNP) placed between two multilayer spin splitters (MSS) which composes the cold neutron spin interferometer. Two spin eigenstates of a neutron polarized x-y plane are split non-dispersively and longitudinally in time by the hf-CNP which could reflect two components alternatively in time. The reduction of the visibility of interference fringes after being superposed by the second MSS is measured as a function of the frequency of the pulser by TOF method. From the zero visibility point obtained by extrapolation one could obtain the longitudinal coherence length of the neutron. (author)

  11. Foot length measurements of newborns of high and low risk pregnancies.

    Science.gov (United States)

    Salge, Ana Karina Marques; Rocha, Érika Lopes; Gaíva, Maria Aparecida Munhoz; Castral, Thaíla Correa; Guimarães, Janaína Valadares; Xavier, Raphaela Maioni

    2017-03-09

    Comparing foot length measurements of newborns in high and low risk pregnancies at a public hospital in Goiânia, GO, Brazil. A cross-sectional study carried out between April, 2013 and May, 2015, with a sample consisting of 180 newborns; 106 infants of women from high-risk pregnancies and 74 of women from low-risk pregnancies. Data were descriptively analyzed. Foot length measurement was performed using a stiff transparent plastic ruler, graduated in millimeters. The length of both feet was measured from the tip of the hallux (big toe) to the end of the heel. A statistically significant relationship was found between the foot length and newborn's weight, between the cephalic and thoracic perimeters in the high-risk group and between the cephalic perimeter in the control group. There is a need for creating cut-off points to identify newborns with intrauterine growth disorders using foot length. Comparar as medidas do comprimento hálux-calcâneo de recém-nascidos em gestações de alto e baixo risco em um hospital público de Goiânia, GO. Estudo transversal, realizado no período de abril de 2013 a maio de 2015, cuja amostra constituiu-se de 180 recém-nascidos, 106 filhos de mulheres com gestação de alto risco e 74 de mulheres com gestação de baixo risco. Os dados foram analisados descritivamente. A medida do comprimento hálux-calcâneo foi realizada utilizando-se de régua plástica transparente rígida, graduada em milímetros. Foram medidos ambos os pés, aferindo-se o comprimento da ponta do hálux até a extremidade do calcâneo. Foi encontrada relação estatisticamente significante entre o comprimento hálux-calcâneo e o peso do recém-nascido, entre os perímetros cefálico e torácico no grupo de alto risco e entre o perímetro cefálico no grupo controle. Existe necessidade da criação de pontos de corte para identificar recém-nascidos com desvios de crescimento intrauterino utilizando-se do comprimento hálux-calcâneo. Comparar las mediciones

  12. Energy levels of one-dimensional systems satisfying the minimal length uncertainty relation

    Energy Technology Data Exchange (ETDEWEB)

    Bernardo, Reginald Christian S., E-mail: rcbernardo@nip.upd.edu.ph; Esguerra, Jose Perico H., E-mail: jesguerra@nip.upd.edu.ph

    2016-10-15

    The standard approach to calculating the energy levels for quantum systems satisfying the minimal length uncertainty relation is to solve an eigenvalue problem involving a fourth- or higher-order differential equation in quasiposition space. It is shown that the problem can be reformulated so that the energy levels of these systems can be obtained by solving only a second-order quasiposition eigenvalue equation. Through this formulation the energy levels are calculated for the following potentials: particle in a box, harmonic oscillator, Pöschl–Teller well, Gaussian well, and double-Gaussian well. For the particle in a box, the second-order quasiposition eigenvalue equation is a second-order differential equation with constant coefficients. For the harmonic oscillator, Pöschl–Teller well, Gaussian well, and double-Gaussian well, a method that involves using Wronskians has been used to solve the second-order quasiposition eigenvalue equation. It is observed for all of these quantum systems that the introduction of a nonzero minimal length uncertainty induces a positive shift in the energy levels. It is shown that the calculation of energy levels in systems satisfying the minimal length uncertainty relation is not limited to a small number of problems like particle in a box and the harmonic oscillator but can be extended to a wider class of problems involving potentials such as the Pöschl–Teller and Gaussian wells.

  13. An automated A-value measurement tool for accurate cochlear duct length estimation.

    Science.gov (United States)

    Iyaniwura, John E; Elfarnawany, Mai; Ladak, Hanif M; Agrawal, Sumit K

    2018-01-22

    There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values (r = 0.70, p value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual measurements by experts. This open-source tool has the potential to benefit

  14. Variable-length code construction for incoherent optical CDMA systems

    Science.gov (United States)

    Lin, Jen-Yung; Jhou, Jhih-Syue; Wen, Jyh-Horng

    2007-04-01

    The purpose of this study is to investigate the multirate transmission in fiber-optic code-division multiple-access (CDMA) networks. In this article, we propose a variable-length code construction for any existing optical orthogonal code to implement a multirate optical CDMA system (called as the multirate code system). For comparison, a multirate system where the lower-rate user sends each symbol twice is implemented and is called as the repeat code system. The repetition as an error-detection code in an ARQ scheme in the repeat code system is also investigated. Moreover, a parallel approach for the optical CDMA systems, which is proposed by Marić et al., is also compared with other systems proposed in this study. Theoretical analysis shows that the bit error probability of the proposed multirate code system is smaller than other systems, especially when the number of lower-rate users is large. Moreover, if there is at least one lower-rate user in the system, the multirate code system accommodates more users than other systems when the error probability of system is set below 10 -9.

  15. Telomere length and depression

    DEFF Research Database (Denmark)

    Wium-Andersen, Marie Kim; Ørsted, David Dynnes; Rode, Line

    2017-01-01

    BACKGROUND: Depression has been cross-sectionally associated with short telomeres as a measure of biological age. However, the direction and nature of the association is currently unclear. AIMS: We examined whether short telomere length is associated with depression cross-sectionally as well...... as prospectively and genetically. METHOD: Telomere length and three polymorphisms, TERT, TERC and OBFC1, were measured in 67 306 individuals aged 20-100 years from the Danish general population and associated with register-based attendance at hospital for depression and purchase of antidepressant medication....... RESULTS: Attendance at hospital for depression was associated with short telomere length cross-sectionally, but not prospectively. Further, purchase of antidepressant medication was not associated with short telomere length cross-sectionally or prospectively. Mean follow-up was 7.6 years (range 0...

  16. Quantum scattering in one-dimensional systems satisfying the minimal length uncertainty relation

    Energy Technology Data Exchange (ETDEWEB)

    Bernardo, Reginald Christian S., E-mail: rcbernardo@nip.upd.edu.ph; Esguerra, Jose Perico H., E-mail: jesguerra@nip.upd.edu.ph

    2016-12-15

    In quantum gravity theories, when the scattering energy is comparable to the Planck energy the Heisenberg uncertainty principle breaks down and is replaced by the minimal length uncertainty relation. In this paper, the consequences of the minimal length uncertainty relation on one-dimensional quantum scattering are studied using an approach involving a recently proposed second-order differential equation. An exact analytical expression for the tunneling probability through a locally-periodic rectangular potential barrier system is obtained. Results show that the existence of a non-zero minimal length uncertainty tends to shift the resonant tunneling energies to the positive direction. Scattering through a locally-periodic potential composed of double-rectangular potential barriers shows that the first band of resonant tunneling energies widens for minimal length cases when the double-rectangular potential barrier is symmetric but narrows down when the double-rectangular potential barrier is asymmetric. A numerical solution which exploits the use of Wronskians is used to calculate the transmission probabilities through the Pöschl–Teller well, Gaussian barrier, and double-Gaussian barrier. Results show that the probability of passage through the Pöschl–Teller well and Gaussian barrier is smaller in the minimal length cases compared to the non-minimal length case. For the double-Gaussian barrier, the probability of passage for energies that are more positive than the resonant tunneling energy is larger in the minimal length cases compared to the non-minimal length case. The approach is exact and applicable to many types of scattering potential.

  17. Analysis of ureteral length in adult cadavers

    Directory of Open Access Journals (Sweden)

    Hugo F. F. Novaes

    2013-04-01

    Full Text Available Introduction In some occasions, correlations between human structures can help planning surgical intra-abdominal interventions. The previous determination of ureteral length helps pre-operatory planning of surgeries, reduces costs of auxiliary exams, the correct choice of double-J catheter with low morbidity and fewer symptoms, and an adequate adhesion to treatment. Objective To evaluate ureteral length in adult cadavers and to analyze its correlation with anthropometric measures. Materials and Methods: From April 2009 to January 2012 we determined ureteral length of adult cadavers submitted to necropsy and obtained the following measures: height, distance from shoulder to wrist, elbow-wrist, xiphoid appendix-umbilicus, umbilicus-pubis, xiphoid appendix-pubis and between iliac spines. We analyzed the correlations between ureteral length and those anthropometric measures. Results We dissected 115 ureters from 115 adult corpses from April 2009 to January 2012. Median ureteral length didn't vary between sexes or according to height. It was observed no correlation among ureteral length and all considered anthropometric measures in all analyzed subgroups and in general population. There were no significant differences between right and left ureteral measures. Conclusions There is no difference of ureteral length in relation to height or gender (male or female. There is no significant correlation among ureteral length and the considered anthropometric measures.

  18. Effect of length of measurement period on accuracy of predicted annual heating energy consumption of buildings

    International Nuclear Information System (INIS)

    Cho, Sung-Hwan; Kim, Won-Tae; Tae, Choon-Soeb; Zaheeruddin, M.

    2004-01-01

    This study examined the temperature dependent regression models of energy consumption as a function of the length of the measurement period. The methodology applied was to construct linear regression models of daily energy consumption from 1 day to 3 months data sets and compare the annual heating energy consumption predicted by these models with actual annual heating energy consumption. A commercial building in Daejon was selected, and the energy consumption was measured over a heating season. The results from the investigation show that the predicted energy consumption based on 1 day of measurements to build the regression model could lead to errors of 100% or more. The prediction error decreased to 30% when 1 week of data was used to build the regression model. Likewise, the regression model based on 3 months of measured data predicted the annual energy consumption within 6% of the measured energy consumption. These analyses show that the length of the measurement period has a significant impact on the accuracy of the predicted annual energy consumption of buildings

  19. Impact of a hospitalist system on length of stay and cost for children with common conditions.

    Science.gov (United States)

    Srivastava, Rajendu; Landrigan, Christopher P; Ross-Degnan, Dennis; Soumerai, Stephen B; Homer, Charles J; Goldmann, Donald A; Muret-Wagstaff, Sharon

    2007-08-01

    This study examined mechanisms of efficiency in a managed care hospitalist system on length of stay and total costs for common pediatric conditions. We conducted a retrospective cohort study (October 1993 to July 1998) of patients in a not-for-profit staff model (HMO 1) and a non-staff-model (HMO 2) managed care organization at a freestanding children's hospital. HMO 1 introduced a hospitalist system for patients in October 1996. Patients were included if they had 1 of 3 common diagnoses: asthma, dehydration, or viral illness. Linear regression models examining length-of-stay-specific costs for prehospitalist and posthospitalist systems were built. Distribution of length of stay for each diagnosis before and after the system change in both study groups was calculated. Interrupted time series analysis tested whether changes in the trends of length of stay and total costs occurred after implementation of the hospitalist system by HMO1 (HMO 2 as comparison group) for all 3 diagnoses combined. A total of 1970 patients with 1 of the 3 study conditions were cared for in HMO 1, and 1001 in HMO 2. After the hospitalist system was introduced in HMO 1, length of stay was reduced by 0.23 days (13%) for asthma and 0.19 days (11%) for dehydration; there was no difference for patients with viral illness. The largest relative reduction in length of stay occurred in patients with a shorter length of stay whose hospitalizations were reduced from 2 days to 1 day. This shift resulted in an average cost-per-case reduction of $105.51 (9.3%) for patients with asthma and $86.22 (7.8%) for patients with dehydration. During the same period, length of stay and total cost rose in HMO 2. Introduction of a hospitalist system in one health maintenance organization resulted in earlier discharges and reduced costs for children with asthma and dehydration compared with another one, with the largest reductions occurring in reducing some 2-day hospitalizations to 1 day. These findings suggest that

  20. The length-weight and length-length relationships of bluefish, Pomatomus saltatrix (Linnaeus, 1766 from Samsun, middle Black Sea region

    Directory of Open Access Journals (Sweden)

    Melek Özpiçak

    2017-10-01

    Full Text Available In this study, length-weight relationship (LWR and length-length relationship (LLR of bluefish, Pomatomus saltatrix were determined. A total of 125 specimens were sampled from Samsun, the middle Black Sea in 2014 fishing season. Bluefish specimens were monthly collected from commercial fishing boats from October to December 2014. All captured individuals (N=125 were measured to the nearest 0.1 cm for total, fork and standard lengths. The weight of each fish (W was recorded to the nearest 0.01 g. According to results of analyses, there were no statistically significant differences between sexes in term of length and weight (P˃0.05. The minimum and maximum total, fork and standard lengths of bluefish ranged between 13.5-23.6 cm, 12.50-21.80 cm and 10.60-20.10 cm, respectively. The equation of length-weight relationship were calculated as W=0.008TL3.12 (r2>0.962. Positive allometric growth was observed for bluefish (b>3. Length-length relationship was also highly significant (P<0.001 with coefficient of determination (r2 ranging from 0.916 to 0.988.

  1. Effect of digital noise reduction on the accuracy of endodontic file length determination

    International Nuclear Information System (INIS)

    Mehdizadeh, Mojdeh; Khademi, Abbas Ali; Shokraneh, Ali; Farhadi, Nastaran

    2013-01-01

    The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO no.08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (a=0.05). Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P 0.05). Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

  2. Device method for accurate measuring length of edible casing%食用肠衣的精确测量装置及方法

    Institute of Scientific and Technical Information of China (English)

    朱秋晨; 孙维连; 孙铂

    2012-01-01

    Edible casing is in light weight, which has higher economic value, resilience, greasy and smooth properties, but it is more difficult to measure the length of that. Through studying the demands of the market, a new machine for measuring the length of edible casing was designed. Its band carrier drew the casing moving and stepping motor controled the speed of band carrier. The data of the measuring wheel were recorded by high-accuracy circle encoder, the speed of stepping motor was regulated by Programmable Logic Controller, and control parameters were inputted and measurement data were showed by touch screen, etc. As the use of key technology, the problems of measurement of edible casing length were solved. The speed reached 0.84 m/s, and the efficiency of the machine was twice of the manual measurement. High automation system makes the work of measuring the length of edible casing reliable and the environment of production healthy. Practice proves that the measurement system of casing can meet the requirements of production process, the measurement error is equal or lesser than 0.4%, the measurement precision was improved.%食用肠衣质量轻,经济价值高,具有弹性、油腻和光滑等特性,精确测量其长度比较困难.通过研究市场的需求,设计了一种肠衣传送测量机构,由传送带牵引肠衣移动,步进电动机控制传送带的速度.采用高精度圆形编码器记录测长轮数据,可编程序控制器调控步进电动机的运行速度,触摸屏输入控制参数和显示测量数据等技术,解决了肠衣精确测量问题.系统的测量速度可达0.84 m/s,测量效率是人工测量的2倍,系统自动化程度高,工作可靠,生产环境卫生.实践证明,肠衣测量系统可满足生产工艺的要求,肠衣测量误差≤0.4%,提高了测量精度.

  3. An apparatus to measure water optical attenuation length for LHAASO-MD

    Science.gov (United States)

    Li, Cong; Xiao, Gang; Feng, Shaohui; Wang, Lingyu; Li, Xiurong; Zuo, Xiong; Cheng, Ning; Wang, Hui; Gao, Bo; Duan, Zhihao; Liu, Jia; He, Huihai; Saeed, Mohsin; Lhaaso Collaboration

    2018-06-01

    The large high altitude air shower observatory (LHAASO) is being constructed at 4400 m a.s.l. in Daocheng, Sichuan Province, aiming to reveal the secrets of cosmic rays origin. And it has the largest surface muon detector array in the world. Due to the needs of calibration and construction of muon detector, we developed a water optical attenuation measurement device using an 8 m long water tank. The results are presented for filtered water at wavelength of 405 nm, which proves this apparatus can reach an accuracy of about 20% at 100 m. This apparatus has not only a high precision measurement of water attenuation length up to 100 m but is also very convenient to be used, which is crucial for water optical properties study during LHAASO detector construction.

  4. Influence of exposure to pesticides on telomere length in tobacco farmers: A biology system approach

    Energy Technology Data Exchange (ETDEWEB)

    Kahl, Vivian Francília Silva [Laboratory of Genetic Toxicology, PPGBioSaúde and PPGGTA, Lutheran University of Brazil (ULBRA), Canoas, RS (Brazil); Silva, Juliana da, E-mail: juliana.silva@ulbra.br [Laboratory of Genetic Toxicology, PPGBioSaúde and PPGGTA, Lutheran University of Brazil (ULBRA), Canoas, RS (Brazil); Rabaioli da Silva, Fernanda, E-mail: fernanda.silva@unilasalle.edu.br [Master’s Degree in Environmental Impact Evaluation, Centro Universitário La Salle, Canoas, RS (Brazil)

    2016-09-15

    Highlights: • Exposure to pesticides in tobacco fields is related to shorten telomere length. • The molecular mechanism of pesticide on telomere length is not fully understood. • Pesticides inhibit ubiquitin proteasome system. • Nicotine activates ubiquitin proteasome system. • Pesticides and nicotine regulate telomere length. - Abstract: Various pesticides in the form of mixtures must be used to keep tobacco crops pest-free. Recent studies have shown a link between occupational exposure to pesticides in tobacco crops and increased damage to the DNA, mononuclei, nuclear buds and binucleated cells in buccal cells as well as micronuclei in lymphocytes. Furthermore, pesticides used specifically for tobacco crops shorten telomere length (TL) significantly. However, the molecular mechanism of pesticide action on telomere length is not fully understood. Our study evaluated the interaction between a complex mixture of chemical compounds (tobacco cultivation pesticides plus nicotine) and proteins associated with maintaining TL, as well as the biological processes involved in this exposure by System Biology tools to provide insight regarding the influence of pesticide exposure on TL maintenance in tobacco farmers. Our analysis showed that one cluster was associated with TL proteins that act in bioprocesses such as (i) telomere maintenance via telomere lengthening; (ii) senescence; (iii) age-dependent telomere shortening; (iv) DNA repair (v) cellular response to stress and (vi) regulation of proteasome ubiquitin-dependent protein catabolic process. We also describe how pesticides and nicotine regulate telomere length. In addition, pesticides inhibit the ubiquitin proteasome system (UPS) and consequently increase proteins of the shelterin complex, avoiding the access of telomerase in telomere and, nicotine activates UPS mechanisms and promotes the degradation of human telomerase reverse transcriptase (hTERT), decreasing telomerase activity.

  5. Influence of exposure to pesticides on telomere length in tobacco farmers: A biology system approach

    International Nuclear Information System (INIS)

    Kahl, Vivian Francília Silva; Silva, Juliana da; Rabaioli da Silva, Fernanda

    2016-01-01

    Highlights: • Exposure to pesticides in tobacco fields is related to shorten telomere length. • The molecular mechanism of pesticide on telomere length is not fully understood. • Pesticides inhibit ubiquitin proteasome system. • Nicotine activates ubiquitin proteasome system. • Pesticides and nicotine regulate telomere length. - Abstract: Various pesticides in the form of mixtures must be used to keep tobacco crops pest-free. Recent studies have shown a link between occupational exposure to pesticides in tobacco crops and increased damage to the DNA, mononuclei, nuclear buds and binucleated cells in buccal cells as well as micronuclei in lymphocytes. Furthermore, pesticides used specifically for tobacco crops shorten telomere length (TL) significantly. However, the molecular mechanism of pesticide action on telomere length is not fully understood. Our study evaluated the interaction between a complex mixture of chemical compounds (tobacco cultivation pesticides plus nicotine) and proteins associated with maintaining TL, as well as the biological processes involved in this exposure by System Biology tools to provide insight regarding the influence of pesticide exposure on TL maintenance in tobacco farmers. Our analysis showed that one cluster was associated with TL proteins that act in bioprocesses such as (i) telomere maintenance via telomere lengthening; (ii) senescence; (iii) age-dependent telomere shortening; (iv) DNA repair (v) cellular response to stress and (vi) regulation of proteasome ubiquitin-dependent protein catabolic process. We also describe how pesticides and nicotine regulate telomere length. In addition, pesticides inhibit the ubiquitin proteasome system (UPS) and consequently increase proteins of the shelterin complex, avoiding the access of telomerase in telomere and, nicotine activates UPS mechanisms and promotes the degradation of human telomerase reverse transcriptase (hTERT), decreasing telomerase activity.

  6. Systemic lupus erythematosus and vitamin D deficiency are associated with shorter telomere length among African Americans: a case-control study.

    Directory of Open Access Journals (Sweden)

    Brett M Hoffecker

    Full Text Available Systemic lupus erythematosus (SLE is a chronic systemic autoimmune disease that disproportionately affects African American females. The causes of SLE are unknown but postulated to be a combination of genetic predisposition and environmental triggers. Vitamin D deficiency is one of the possible environmental triggers. In this study we evaluated relationships between vitamin D status, cellular aging (telomere length and anti-telomere antibodies among African American Gullah women with SLE. The study population included African American female SLE patients and unaffected controls from the Sea Island region of South Carolina. Serum 25-hydroxyvitamin D levels were measured using a nonchromatographic radioimmunoassay. Telomere length was measured in genomic DNA of peripheral blood mononuclear cells (PBMCs by monochrome multiplex quantitative PCR. Anti-telomere antibody levels were measured by enzyme-linked immunosorbent assay (ELISA. Patients with SLE had significantly shorter telomeres and higher anti-telomere antibody titers compared to age- and gender-matched unaffected controls. There was a positive correlation between anti-telomere antibody levels and disease activity among patients and a significant correlation of shorter telomeres with lower 25-hydroxyvitamin D levels in both patients and controls. In follow-up examination of a subset of the patients, the patients who remained vitamin D deficient tended to have shorter telomeres than those patients whose 25-hydroxyvitamin D levels were repleted. Increasing 25-hydroxyvitamin D levels in African American patients with SLE may be beneficial in maintaining telomere length and preventing cellular aging. Moreover, anti-telomere antibody levels may be a promising biomarker of SLE status and disease activity.

  7. Alternatives Generation Analysis Long Length Contaminated Equipment Removal System Storage

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    Major pieces of Characterization sampling equipment are currently stored outdoors. This includes the Long Length Contaminated Equipment receiver trailer and transportation trailer. A decision is required to determine the preferred alternative for facilities to store and maintain this equipment. The Long Length Contaminated Equipment Removal System (LLCERS) consists of many tools, mechanisms, and controllers currently stored in various locations. Much of this equipment should be protected from the elements while being stored. Some of the LLCERS equipment should be protected with some kind of roof cover. This decision analysis is to determine the best alternative for weather protection for the large equipment requiring a cover. Additional details are included in Sections 2.0 and 5.0. Key assumptions used in this analysis are detailed in Section 3.2

  8. Sample preparation and scanning protocol for computerised analysis of root length and diameter

    NARCIS (Netherlands)

    Bouma, T.J.; Nielsen, K.F.; Koutstaal, B.P.

    2000-01-01

    Root length and diameter distribution are important characteristics to be considered when describing and comparing root systems. Root length and root-diameter distribution may be obtained in two ways: by microscopical measurements, which are laborious, or by computerised analysis, which is fast but

  9. Influence of slab length on dynamic characteristics of subway train-steel spring floating slab track-tunnel coupled system

    Directory of Open Access Journals (Sweden)

    Qing-yuan Xu

    Full Text Available A subway train-steel spring floating slab track-tunnel coupling dynamic model, considering short and middle-long wavelength random track irregularities, and longitudinal connection between adjacent slabs of steel spring floating slab track, was developed. And the influence of slab length on dynamic characteristics of the system under different track conditions and train speeds are theoretically studied. The calculated results show: (1 In general, the acceleration of each component of the coupled system decreases with the increase of slab length under the perfectly smooth track condition; (2 Slab length has different influence laws on acceleration of each component of subway train-steel spring floating slab track-tunnel coupled system under random irregularity of track condition. The lower the dominant frequency distribution of vibration acceleration is, the higher influence slab length has; (3 With the increase of slab length, the force of rail, fastener and steel spring also decreases significantly, which helps to lengthen the service life of these components; (4 With the increase of slab length, the longitudinal bending moment of slab increases sharply at first, then it begins to drop slightly. When slab length exceeds the distance between two bogies of a vehicle, the longitudinal bending moment of slab changes little; (5 Slab length has significant influence on the dynamic force and displacement of the coupled system when train speed is higher.

  10. Naloxone fails to prolong seizure length in ECT.

    Science.gov (United States)

    Rasmussen, K G; Pandurangi, A K

    1999-12-01

    Electroconvulsive shock (ECS) in animals has been shown to enhance endogenous opiate systems. The anticonvulsant effects of ECS are also partially blocked by the opiate receptor antagonist naloxone, leading some investigators to postulate that the anticonvulsant effects of ECS are mediated by activation of endogenous opiates. If such a phenomenon occurs in humans, then naloxone might prolong seizure length in electroconvulsive therapy (ECT). In the present study, nine patients were given 2.0 mg intravenous (i.v.) naloxone 2 minutes prior to one-half of their ECT treatments. Motor seizure length was measured via the cuff technique. EEG tracings were read by an investigator blind to naloxone status. There was no difference between the two groups in either EEG or nonblindly evaluated motor seizure length. It is concluded that a dose of 2 mg naloxone does not effectively increase seizure length in ECT.

  11. A magnetic suspension system for measuring liquid density

    Directory of Open Access Journals (Sweden)

    Luz María Centeno González

    2013-01-01

    Full Text Available Density is a derived quantity of mass and length; it is defined as mass per volume unit and its SI unit is kg/m3. National metrology institutes have been designing and building their own magnetic suspension systems during the last 5 decades for making fluid density measurements; this has allowed them to carry out research into liquids and gases’ physical characteristics. This paper was aimed at designing and developing a magnetic suspension system for a magnetic balance used in determining liquid density to be used in CENAM’s metrology density laboratories.

  12. Long Length Contaminated Equipment Retrieval System Receiver Trailer and Transport Trailer Operations and Maintenance Manual

    International Nuclear Information System (INIS)

    DALE, R.N.

    2000-01-01

    A system to accommodate the removal of long-length contaminated equipment (LLCE) from Hanford underground radioactive waste storage tanks was designed, procured, and demonstrated, via a project activity during the 1990s. The system is the Long Length Contaminated Equipment Removal System (LLCERS). LLCERS will be maintained and operated by Tank Farms Engineering and Operations organizations and other varied projects having a need for the system. The responsibility for the operation and maintenance of the LLCERS Receiver Trailer (RT) and Transport Trailer (TT) resides with the RPP Characterization Project Operations organization. The purpose of this document is to provide vendor supplied operating and maintenance (O and M) information for the RT and TT in a readily retrievable form. This information is provided this way instead of in a vendor information (VI) file to maintain configuration control of the operations baseline as described in RPP-6085, ''Configuration Management Plan for Long Length Contaminated Equipment Receiver and Transport Trailers''. Additional Operations Baseline documents are identified in RPP-6085

  13. Direct measurement of sub-Debye-length attraction between oppositely charged surfaces.

    Science.gov (United States)

    Kampf, Nir; Ben-Yaakov, Dan; Andelman, David; Safran, S A; Klein, Jacob

    2009-09-11

    Using a surface force balance with fast video analysis, we have measured directly the attractive forces between oppositely charged solid surfaces (charge densities sigma(+), sigma(-)) across water over the entire range of interaction, in particular, at surface separations D below the Debye screening length lambda(S). At very low salt concentration we find a long-ranged attraction between the surfaces (onset ca. 100 nm), whose variation at D

  14. The use of 'arms-length' organizations for health system change in Ontario, Canada: some observations by insiders.

    Science.gov (United States)

    Pink, George H; Leatt, Peggy

    2003-01-01

    During the past decade, there has been substantial health system reform in the United States, United Kingdom, New Zealand, and many other countries. For the most part, Canada has not pursued 'big bang' health system change but rather a variety of strategies to achieve incremental change. In this paper, we present the ways in which three arms-length organizations have been used by government to effect incremental system change in Ontario during the past several years. We observe that, (1) the influence of politics and political interference can be reduced through an arms-length organization; (2) an arms-length organization with the power to make decisions entails more political risk for government and encounters more scrutiny and criticism by providers and the media than an organization with the power to recommend only; (3) an arms-length organization with a limited lifespan faces more delaying tactics by adversely affected parties than an organization without a limited lifespan; (4) an arms-length organization with perceived influence may attract causes that are not related to its mandate; (5) the importance and difficulty of communicating complex information about system change to a wide variety of audiences cannot be overstated; (6) system change informed by the use of expert opinion encounters less provider resistance and may result in better decisions; and (7) the reputation of the Chair and the perceived competence and experience of the CEO are critical success factors in the success of an arms-length organization.

  15. Development of CANDU fuel in-bay inspection and dimensional measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Chang Keun; Cho, Moon Sung; Suk, Ho Chun; Koo, Dae Seo; Park, Kwang June; Jun, Ji Su; Jung, Jong Yeob

    2004-09-01

    In this report, we describe a spent fuel inspection and dimensional measuring system for CANDU fuel bundles in atmosphere or water. The submissible camera with radiation resistance was used to inspect a spent fuel in water. The design criteria of the dimensional measuring system was set up {+-}0.01mm(10{mu}m) for measuring accuracy. The LVDT (Linear Variable Differential Transformer) was used as measuring sensor in this dimensional measuring system. An LVDT calibration equipment was developed in order to satisfy the required accuracy of the system. Also, aluminum master and CANDU Master with same dimension of fuel bundle was made to calibrate the mechanical error of the dimensional measuring system. The accuracy of the fuel inspection system was examined. The results show that the accuracy in dimensional measurement of fuel rod profile and bearing pad profile, diameter of fuel bundle, fuel rod length, and end plate profile using standard test equipment satisfies the design criteria, i.e., maximum measurement error of {+-}0.01mm(10{mu}m)

  16. Measurement of metal/carbon nanotube contact resistance by adjusting contact length using laser ablation

    Energy Technology Data Exchange (ETDEWEB)

    Lan Chun; Srisungsitthisunti, Pornsak; Amama, Placidus B; Fisher, Timothy S; Xu Xianfan; Reifenberger, Ronald G [Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907 (United States)], E-mail: lan0@physics.purdue.edu

    2008-03-26

    A technique of measuring contact resistance between an individual nanotube and a deposited metallic film is described. Using laser ablation to sequentially shorten the contact length between a nanotube and the evaporated metallic film, the linear resistivity of the nanotube as well as the specific contact resistivity between the nanotube and metallic film can be determined. This technique can be generally used to measure the specific contact resistance that develops between a metallic film and a variety of different nanowires and nanotubes.

  17. Voxel effects within digital images of trabecular bone and their consequences on chord-length distribution measurements

    International Nuclear Information System (INIS)

    Rajon, D.A.; Shah, A.P.; Watchman, C.J.; Bolch, W.E.; Jokisch, D.W.; Patton, P.W.

    2002-01-01

    Chord-length distributions through the trabecular regions of the skeleton have been investigated since the early 1960s. These distributions have become important features for bone marrow dosimetry; as such, current models rely on the accuracy of their measurements. Recent techniques utilize nuclear magnetic resonance (NMR) microscopy to acquire 3D images of trabecular bone that are then used to measure 3D chord-length distributions by Monte Carlo methods. Previous studies have shown that two voxel effects largely affect the acquisition of these distributions within digital images. One is particularly pertinent as it dramatically changes the shape of the distribution and reduces its mean. An attempt was made to reduce this undesirable effect and good results were obtained for a single-sphere model using minimum acceptable chord (MAC) methods (Jokisch et al 2001 Med. Phys. 28 1493-504). The goal of the present work is to extend the study of these methods to more general models in order to better quantify their consequences. First, a mathematical model of a trabecular bone sample was used to test the usefulness of the MAC methods. The results showed that these methods were not efficient for this simulated bone model. These methods were further tested on a single voxelized sphere over a large range of voxel sizes. The results showed that the MAC methods are voxel-size dependent and overestimate the mean chord length for typical resolutions used with NMR microscopy. The study further suggests that bone and marrow chord-length distributions currently utilized in skeletal dosimetry models are most likely affected by voxel effects that yield values of mean chord length lower than their true values. (author)

  18. Is sonographically measured cervical length at 37 weeks of gestation associated with intrapartum cesarean section? A prospective cohort study.

    Science.gov (United States)

    de Vries, Bradley; Narayan, Rajit; McGeechan, Kevin; Santiagu, Stanley; Vairavan, Ramesh; Burke, Minke; Phipps, Hala; Hyett, Jon

    2018-02-16

    Cesarean section rates continue to increase globally. Prediction of intrapartum cesarean section could lead to preventive measures. Our aim was to assess the association between sonographically measured cervical length at 37 weeks of gestation and cesarean section among women planning a vaginal birth. The population was women with a low-risk pregnancy or with gestational diabetes. This was a prospective cohort study conducted in a tertiary referral hospital in Sydney, Australia. In all, 212 women with a low-risk pregnancy or with gestational diabetes were recruited including 158 nulliparous and 54 parous women. Maternal demographic, clinical and ultrasound characteristics were collected at 37 weeks of gestation. Semi-Bayesian logistic regression and Markov chain Monte Carlo simulation were used to assess the relationship between cervical length and cesarean section in labor. Rates of cesarean section were 5% (2/55) for cervical length ≤20 mm, 17% (17/101) for cervical length 20-32 mm, and 27% (13/56) for cervical length >32 mm. These rates were 4, 22 and 33%, respectively, in nulliparous women. In the semi-Bayesian analysis, the odds ratio for cesarean section was 6.2 (95% confidence interval 2.2-43) for cervical length 20-32 mm and 10 (95% confidence interval 4.8-74) for cervical length >32 mm compared with the lowest quartile of cervical length, after adjusting for maternal age, parity, height, prepregnancy body mass index, gestational diabetes, induction of labor, neonatal sex and birthweight centile. Cervical length at 37 weeks of gestation is associated with intrapartum cesarean section. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  19. Effects of correlations between particle longitudinal positions and transverse plane on bunch length measurement: a case study on GBS electron LINAC at ELI-NP

    Science.gov (United States)

    Sabato, L.; Arpaia, P.; Cianchi, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Variola, A.

    2018-02-01

    In high-brightness LINear ACcelerators (LINACs), electron bunch length can be measured indirectly by a radio frequency deflector (RFD). In this paper, the accuracy loss arising from non-negligible correlations between particle longitudinal positions and the transverse plane (in particular the vertical one) at RFD entrance is analytically assessed. Theoretical predictions are compared with simulation results, obtained by means of ELEctron Generation ANd Tracking (ELEGANT) code, in the case study of the gamma beam system (GBS) at the extreme light infrastructure—nuclear physics (ELI-NP). In particular, the relative error affecting the bunch length measurement, for bunches characterized by both energy chirp and fixed correlation coefficients between longitudinal particle positions and the vertical plane, is reported. Moreover, the relative error versus the correlation coefficients is shown for fixed RFD phase 0 rad and π rad. The relationship between relative error and correlations factors can help the decision of using the bunch length measurement technique with one or two vertical spot size measurements in order to cancel the correlations contribution. In the case of the GBS electron LINAC, the misalignment of one of the quadrupoles before the RFD between  -2 mm and 2 mm leads to a relative error less than 5%. The misalignment of the first C-band accelerating section between  -2 mm and 2 mm could lead to a relative error up to 10%.

  20. Standing Height and its Estimation Utilizing Foot Length Measurements in Adolescents from Western Region in Kosovo

    Directory of Open Access Journals (Sweden)

    Stevo Popović

    2017-10-01

    Full Text Available The purpose of this research is to examine standing height in both Kosovan genders in the Western Region as well as its association with foot length, as an alternative to estimating standing height. A total of 664 individuals (338 male and 326 female participated in this research. The anthropometric measurements were taken according to the protocol of ISAK. The relationships between body height and foot length were determined using simple correlation coefficients at a ninety-five percent confidence interval. A comparison of means of standing height and foot length between genders was performed using a t-test. After that a linear regression analysis were carried out to examine extent to which foot length can reliably predict standing height. Results displayed that Western Kosovan male are 179.71±6.00cm tall and have a foot length of 26.73±1.20cm, while Western Kosovan female are 166.26±5.23cm tall and have a foot length of 23.66±1.06cm. The results have shown that both genders made Western-Kosovans a tall group, a little bit taller that general Kosovan population. Moreover, the foot length reliably predicts standing height in both genders; but, not reliably enough as arm span. This study also confirms the necessity for developing separate height models for each region in Kosovo as the results from Western-Kosovans don’t correspond to the general values.

  1. Comparison of two cut-to-length harvesting systems operating in eastern hardwoods

    Science.gov (United States)

    Chris B. LeDoux; Niel K. Huyler

    2001-01-01

    We compared production rates, operating costs, and break-even points (BEP) for small and large cut-to-length (CTL) harvesting systems operating at several machine utilization rates (MUR) in mixed hardwood and softwood stands in Vermont.

  2. A QoS-Based Dynamic Queue Length Scheduling Algorithm in Multiantenna Heterogeneous Systems

    Directory of Open Access Journals (Sweden)

    Verikoukis Christos

    2010-01-01

    Full Text Available The use of real-time delay-sensitive applications in wireless systems has significantly grown during the last years. Therefore the designers of wireless systems have faced a challenging issue to guarantee the required Quality of Service (QoS. On the other hand, the recent advances and the extensive use of multiple antennas have already been included in several commercial standards, where the multibeam opportunistic transmission beamforming strategies have been proposed to improve the performance of the wireless systems. A cross-layer-based dynamically tuned queue length scheduler is presented in this paper, for the Downlink of multiuser and multiantenna WLAN systems with heterogeneous traffic requirements. To align with modern wireless systems transmission strategies, an opportunistic scheduling algorithm is employed, while a priority to the different traffic classes is applied. A tradeoff between the maximization of the throughput of the system and the guarantee of the maximum allowed delay is obtained. Therefore, the length of the queue is dynamically adjusted to select the appropriate conditions based on the operator requirements.

  3. Industrial process. Solartron installs the KME measuring and testing system at Civaux

    International Nuclear Information System (INIS)

    Foucher, N.

    1997-01-01

    The Solartron company wined the European call for offer of EdF/CNEPE for the installation of the KME measuring and testing system on the first unit of the Civaux nuclear power plant (France). This system is based on the IMP centralized measurement system, the SNET network and a SNET/ETHERNET interface. Measurement electronic devices are installed in the vicinity of the sensors which reduces the costs and the wires length. Logical and analogical data acquisition is performed by 35 IMP systems which can be connected to 72 different points. The communication with the PATERN data management system is performed by a second independent ETHERNET network. This system ensures the database management and the calculation of the thermodynamical, mechanical and electrical parameters. (J.S.)

  4. 23 CFR Appendix D to Part 658 - Devices That Are Excluded From Measurement of the Length or Width of a Commercial Motor Vehicle

    Science.gov (United States)

    2010-04-01

    ...; (v) Tarp basket; (w) Tire carrier; and (x) Uppercoupler. 2. Devices excluded from length measurement... measurement are side rails running the length of the vehicle and rear doors, provided the only function of the...

  5. Phase Behavior and Evaporation Profile of Tween 20 - Eugenol System. Effect of Different Alkane Chain Length and Solvent System

    International Nuclear Information System (INIS)

    Kassim, A.; Lim, W.H.; Kuangl, D.; Rusmawati, W.W.M.; Abdullah, A.H.; Teoh, S.P.

    2003-01-01

    The isotropic region of Tween 20/eugenol/n-alkane in aqueous systems was determined. The solubilisation trend of isotropic solution formed in the presence of eugenol was studied as a function of different alkyl chain length of n-alkane. The solubility of solvent in surfactant solution is dependent on their molecular polarity. An increase in n-alkane chain length (lower polarity) lead to smaller isotropic region which will affect the surfactant partitioning between the interface, the oil phase and the aqueous phase of the microemulsion as the oil chain length is varied. The changes of evaporation behaviour were affected strongly by the types of phases existed in the systems. The increment of n-alkane and water content led to higher evaporation rate. But the formation of w/o microemulsion would lower the evaporation rate because water molecules were trapped in the core of aggregates. In solubilisation system, evaporation rate is dependent on the solvent content and the interaction between Tween 20 and solvent molecules in the mixed composition. (author)

  6. Roentgenologic investigations for the anterior tooth length

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Won Pyo; Ahn, Hyung Kyu [College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1972-11-15

    The author measured the length of crown, root and tooth on the films which was taken by intraoral bisecting technic with mesh plate on the films. The films were taken from the dry skulls, dentiform, same patients who had to be removed their upper incisors, and the other patients who admitted for dental care. From this serial experiment the results were made as follows: 1. By using the film and mesh plate in the oral cavity, the real tooth length can be measured easily on the film surfaces. 2. The film distortion in the oral cavity can be avoided when taking the film using the mesh plate and film together. 3. When measuring the film, length of crown was elongated and length of root was shortened. 4. When using the well-trained bisecting technic, the real tooth length can be measured directly on the intraoral film.

  7. Long Length Contaminated Equipment Retrieval System Receiver Trailer and Transport Trailer Operations and Maintenance Manual

    Energy Technology Data Exchange (ETDEWEB)

    DALE, R.N.

    2000-05-01

    A system to accommodate the removal of long-length contaminated equipment (LLCE) from Hanford underground radioactive waste storage tanks was designed, procured, and demonstrated, via a project activity during the 1990s. The system is the Long Length Contaminated Equipment Removal System (LLCERS). LLCERS will be maintained and operated by Tank Farms Engineering and Operations organizations and other varied projects having a need for the system. The responsibility for the operation and maintenance of the LLCERS Receiver Trailer (RT) and Transport Trailer (TT) resides with the RPP Characterization Project Operations organization. The purpose of this document is to provide vendor supplied operating and maintenance (O & M) information for the RT and TT in a readily retrievable form. This information is provided this way instead of in a vendor information (VI) file to maintain configuration control of the operations baseline as described in RPP-6085, ''Configuration Management Plan for Long Length Contaminated Equipment Receiver and Transport Trailers''. Additional Operations Baseline documents are identified in RPP-6085.

  8. Determination of ππ scattering lengths from measurement of π+π- atom lifetime

    International Nuclear Information System (INIS)

    Adeva, B.; Afanasyev, L.; Benayoun, M.; Benelli, A.; Berka, Z.; Brekhovskikh, V.; Caragheorgheopol, G.; Cechak, T.; Chiba, M.; Chliapnikov, P.V.; Ciocarlan, C.; Constantinescu, S.; Costantini, S.; Curceanu, C.; Doskarova, P.; Dreossi, D.; Drijard, D.; Dudarev, A.; Ferro-Luzzi, M.; Fungueirino Pazos, J.L.

    2011-01-01

    The DIRAC experiment at CERN has achieved a sizeable production of π + π - atoms and has significantly improved the precision on its lifetime determination. From a sample of 21 227 atomic pairs, a 4% measurement of the S-wave ππ scattering length difference |a 0 -a 2 |=(0.2533 -0.0078 +0.0080 | stat +0.0078 -0.0073 | syst )M π + -1 has been attained, providing an important test of Chiral Perturbation Theory.

  9. Controlling the optical path length in turbid media using differential path-length spectroscopy: fiber diameter dependence

    NARCIS (Netherlands)

    Kaspers, O. P.; Sterenborg, H. J. C. M.; Amelink, A.

    2008-01-01

    We have characterized the path length for the differential path-length spectroscopy (DPS) fiber optic geometry for a wide range of optical properties and for fiber diameters ranging from 200 mu m to 1000 mu m. Phantom measurements show that the path length is nearly constant for scattering

  10. Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas

    2015-01-01

    A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing......, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius...

  11. Accuracy of two root canal length measurement devices integrated into rotary endodontic motors when removing gutta-percha from root-filled teeth.

    Science.gov (United States)

    Uzun, O; Topuz, O; Tinaz, C; Nekoofar, M H; Dummer, P M H

    2008-09-01

    To evaluate ex vivo the accuracy of the integrated electronic root canal length measurement devices within TCM Endo V and Tri Auto ZX motors whilst removing gutta-percha and sealer from filled root canals. Forty freshly extracted maxillary and mandibular incisor teeth with mature apices were selected. Following access cavity preparation, the length of the root canals were measured visually 0.5 mm short of the major foramen (TL). The canals were prepared using the HERO 642 system and then filled with gutta-percha and AH26 sealer using a lateral compaction technique. After 7 days the coronal temporary filling was removed and the roots mounted in an alginate experimental model. The roots were then randomly divided in two groups. The access cavities were filled with chloroform to soften the gutta-percha and allow its penetration using the Tri Auto ZX and the TCM Endo V devices in groups 1 and 2, respectively. The 'automatic apical reverse function' (ARL) of both devices was set to start at the 0.5 setting and the rotary instrument inserted inside the root canal until a beeping sound was heard and the rotation of the file stopped automatically. Once the auto reverse function had been initiated, the foot pedal of the motor was inactivated and the rubber stop placed against the reference point. The distance between the file tip and rubber stop was measured using a digital calliper to 0.01 mm accuracy (ARL). Then, a size 20, 0.02 taper instrument was attached to each device and inserted into the root canals without rotary motion until the integrated ERCLMDs positioned the instrument tips at the 0.5 setting as suggested by the devices. This length was again measured using a digital calliper (EL). The Mann-Whitney U-test was used to investigate statistical differences between the true canal length and those indicated by the two devices when used in 'automatic ARL and when inserted passively (EL). In the presence of gutta-percha, sealer and chloroform, the auto

  12. Scaling of localization length of a quasi 1D system with longitudinal boundary roughness

    International Nuclear Information System (INIS)

    Abhijit Kar Gupta; Sen, A.K.

    1994-08-01

    We introduce irregularities on one of the longitudinal boundaries of a quasi 1D strip which has no bulk disorder. We calculate the localization length of such a system within the scope of tight-binding formalism and see how it behaves with the roughness introduced on the boundary and with the strip-width. We find that localization length scales with a composite one parameter. (author). 6 refs, 4 figs

  13. Ultrasonic motion analysis system - measurement of temporal and spatial gait parameters

    NARCIS (Netherlands)

    Huitema, RB; Hof, AL; Postema, K

    The duration of stance and swing phase and step and stride length are important parameters in human gait. In this technical note a low-cost ultrasonic motion analysis system is described that is capable of measuring these temporal and spatial parameters while subjects walk on the floor. By using the

  14. Philtrum length and intercommissural distance measurements at mixed dentition period.

    Science.gov (United States)

    Mostafa, Mostafa; Hassib, Nehal; Sayed, Inas; Neamat, Amany; Ramzy, Magda; El-Badry, Tarek; ElGabry, Hisham; Salem, Haidy; Omar, Nada; Ismail, Amira; Ibrahim, Yousra; Shebaita, Amr; Allam, Ahmed; Mostafa, Magdy

    2018-05-01

    Anthropometric measurements of the lip and mouth are of great importance in clinical dysmorphology as well as reconstructive plastic surgery. In this study, the philtrum length (PhL) and intercommissural distance (ICmD) nomograms for Egyptian children in the mixed dentition period were established. A group of 1,338 Egyptian students in primary schools (735 boys and 603 girls) were included in the study. The students were at mixed dentition period and their ages ranged from 7 to 12 years. Anthropometric norms of PhL and ICmD were developed with significant sex difference in certain groups. A ratio between PhL and ICmD was developed. These data will help facilitate both objective and subjective evaluation of the lip and mouth for proper diagnosis of orofacial anomalies and variations as well as for ideal treatment plans. © 2018 Wiley Periodicals, Inc.

  15. The predictive value of quantitative fibronectin testing in combination with cervical length measurement in symptomatic women

    NARCIS (Netherlands)

    Bruijn, Merel M. C.; Kamphuis, Esme I.; Hoesli, Irene M.; Martinez de Tejada, Begoña; Loccufier, Anne R.; Kühnert, Maritta; Helmer, Hanns; Franz, Marie; Porath, Martina M.; Oudijk, Martijn A.; Jacquemyn, Yves; Schulzke, Sven M.; Vetter, Grit; Hoste, Griet; Vis, Jolande Y.; Kok, Marjolein; Mol, Ben W. J.; van Baaren, Gert-Jan

    2016-01-01

    The combination of the qualitative fetal fibronectin test and cervical length measurement has a high negative predictive value for preterm birth within 7 days; however, positive prediction is poor. A new bedside quantitative fetal fibronectin test showed potential additional value over the

  16. Adjustable, short focal length permanent-magnet quadrupole based electron beam final focus system

    Directory of Open Access Journals (Sweden)

    J. K. Lim

    2005-07-01

    Full Text Available Advanced high-brightness beam applications such as inverse-Compton scattering (ICS depend on achieving of ultrasmall spot sizes in high current beams. Modern injectors and compressors enable the production of high-brightness beams having needed short bunch lengths and small emittances. Along with these beam properties comes the need to produce tighter foci, using stronger, shorter focal length optics. An approach to creating such strong focusing systems using high-field, small-bore permanent-magnet quadrupoles (PMQs is reported here. A final-focus system employing three PMQs, each composed of 16 neodymium iron boride sectors in a Halbach geometry has been installed in the PLEIADES ICS experiment. The field gradient in these PMQs is 560   T/m, the highest ever reported in a magnetic optics system. As the magnets are of a fixed field strength, the focusing system is tuned by adjusting the position of the three magnets along the beam line axis, in analogy to familiar camera optics. This paper discusses the details of the focusing system, simulation, design, fabrication, and experimental procedure in creating ultrasmall beams at PLEIADES.

  17. The comparison between the length of vertical dimension of occlusion and the length of thumb on undergraduate Mongoloid students

    Directory of Open Access Journals (Sweden)

    Goh Li Teng

    2011-03-01

    Full Text Available The Thumb Rule of Leonardo da Vinci states that many proportions of the face show relationship with the length of thumb which is measured from the proximal tip of the proximal phalanx to the distal tip of the distal phalanx. Previous studies have shown that the length of the vertical dimension of occlusion (VDO is similar to the length of thumb of the Caucasoid race. The purpose of this study is to determine whether the length of VDO have correlations with the length of thumb among those of the Mongoloid race. This study took a survey method with the analytical cross-sectional approach. A total of 80 students of Faculty of Dentistry who have fulfilled all population criteria were randomly chosen to measure the length of VDO and the length of the thumb. Results analyzed with Student's t-test statistic revealed that there was a significant difference between males and females in the length of VDO and the length of the thumb, however, there was no significant difference between the length of VDO and the length of the thumb. There were very strong correlations (P<0.05 between the length of VDO and the length of the thumb. As a conclusion, the length of thumb can be suggested as an objective method to determine the length of VDO in this population.

  18. Development of a Data Reduction Algorithm for Optical Wide Field Patrol (OWL) II: Improving Measurement of Lengths of Detected Streaks

    Science.gov (United States)

    Park, Sun-Youp; Choi, Jin; Roh, Dong-Goo; Park, Maru; Jo, Jung Hyun; Yim, Hong-Suh; Park, Young-Sik; Bae, Young-Ho; Park, Jang-Hyun; Moon, Hong-Kyu; Choi, Young-Jun; Cho, Sungki; Choi, Eun-Jung

    2016-09-01

    As described in the previous paper (Park et al. 2013), the detector subsystem of optical wide-field patrol (OWL) provides many observational data points of a single artificial satellite or space debris in the form of small streaks, using a chopper system and a time tagger. The position and the corresponding time data are matched assuming that the length of a streak on the CCD frame is proportional to the time duration of the exposure during which the chopper blades do not obscure the CCD window. In the previous study, however, the length was measured using the diagonal of the rectangle of the image area containing the streak; the results were quite ambiguous and inaccurate, allowing possible matching error of positions and time data. Furthermore, because only one (position, time) data point is created from one streak, the efficiency of the observation decreases. To define the length of a streak correctly, it is important to locate the endpoints of a streak. In this paper, a method using a differential convolution mask pattern is tested. This method can be used to obtain the positions where the pixel values are changed sharply. These endpoints can be regarded as directly detected positional data, and the number of data points is doubled by this result.

  19. Performance and calibration of wave length shifting fibers for K2K SciBar detector

    International Nuclear Information System (INIS)

    Morita, Taichi

    2004-01-01

    The wave length shifting (WLS) fibers (Kuraray Y11 (200) MS) are used for light collection from scintillators in the SciBar detector. The performance of WLS fibers was measured before installation. Because the number of WLS fibers is about 15,000, it is necessary to make a system to measure attenuation length of WLS fibers efficiently. I will report the pre-calibration method for measurement and the performance of the WLS fibers in SciBar detector. (author)

  20. Disentangling behavior in early child development : Interpretability of early child language and its effect on utterance length measures

    NARCIS (Netherlands)

    Van Dijk, M.W.G.; Van Geert, P. L. C.

    Early child speech is often difficult to understand and interpret. Usually, these unintelligible units are not included in quantitative measures, such as MLU. In this paper, we claim that these interpretation problems have an unknown effect on utterance length measures (such as MLU), since we have

  1. The length of the male urethra

    Directory of Open Access Journals (Sweden)

    Tobias. S. Kohler

    2008-08-01

    Full Text Available PURPOSE: Catheter-based medical devices are an important component of the urologic armamentarium. To our knowledge, there is no population-based data regarding normal male urethral length. We evaluated the length of the urethra in men with normal genitourinary anatomy undergoing either Foley catheter removal or standard cystoscopy. MATERIALS AND METHODS: Male urethral length was obtained in 109 men. After study permission was obtained, the subject's penis was placed on a gentle stretch and the catheter was marked at the tip of the penis. The catheter was then removed and the distance from the mark to the beginning of the re-inflated balloon was measured. Alternatively, urethral length was measured at the time of cystoscopy, on removal of the cystoscope. Data on age, weight, and height was obtained in patients when possible. RESULTS: The mean urethral length was 22.3 cm with a standard deviation of 2.4 cm. Urethral length varied between 15 cm and 29 cm. No statistically significant correlation was found between urethral length and height, weight, body mass index (BMI, or age. CONCLUSIONS: Literature documenting the length of the normal male adult urethra is scarce. Our data adds to basic anatomic information of the male urethra and may be used to optimize genitourinary device design.

  2. The impact of length of stay on recovery measures in faith-based addiction treatment.

    Science.gov (United States)

    Lashley, Mary

    2018-03-30

    To determine the impact of length of stay among homeless men in faith-based residential addictions recovery on physical activity, depression, self-esteem, and nicotine dependence. A time series design was utilized to measure changes in the four quality measures at program entry and at 3, 6, and 9 months following admission. The sample consisted of 175 homeless residents enrolled in a faith-based residential recovery program. Paired t tests were used to determine the change in average instrument response from admission to each follow-up period. Analysis of variance (ANOVA) and Tukey posthoc tests were used to assess for differences in length of stay between demographic variables. Statistically significant improvements were noted in self-esteem and depressive symptomatology at 3 and 6 months following admission and in physical activity levels at 3 months following admission. Nicotine dependence scores declined at 3 and 6 months but were not statistically significant. Time spent in this faith-based spiritual recovery program had a significant impact on depression, self-esteem, and physical activity. Recommendations for future study include conducting research to analyze the relationship between distinct program elements and quality indicators and comparing faith-based programs to other similar programs and to publicly funded secular recovery programs. © 2018 Wiley Periodicals, Inc.

  3. Local-field refinement of neutron scattering lengths

    International Nuclear Information System (INIS)

    Sears, V.F.

    1985-01-01

    We examine the way in which local field effects in the neutron refractive index affect the values of coherent scattering lengths determined by various kinds of neutron optical measurements. We find that under typical experimental conditions these effects are negligible for interferometry measurements but that they are significant for gravity refractometry measurements, producing changes in the effective scattering length of as much as two or three standard deviations in some cases. Refined values of the scattering length are obtained for the thirteen elements for which data are presently available. The special role of local field effects in neutron transmission is also discussed. (orig.)

  4. Local-field refinement of neutron scattering lengths

    Energy Technology Data Exchange (ETDEWEB)

    Sears, V F

    1985-06-01

    We examine the way in which local field effects in the neutron refractive index affect the values of coherent scattering lengths determined by various kinds of neutron optical measurements. We find that under typical experimental conditions these effects are negligible for interferometry measurements but that they are significant for gravity refractometry measurements, producing changes in the effective scattering length of as much as two or three standard deviations in some cases. Refined values of the scattering length are obtained for the thirteen elements for which data are presently available. The special role of local field effects in neutron transmission is also discussed.

  5. Units of measurement past, present and future international system of units

    CERN Document Server

    Gupta, S V

    2010-01-01

    It is for the first time that the subject of quantities and their respective units is dealt this much in detail a glimpse of units of measurements of base quantities of length, time, mass and volume is given for ancient India three and four dimensional systems of measurement units are critically examined establishment of the fact that only four base units are needed to describe a system of units the basics to arrive at the unit of a derived quantity are explained basic, derived and dimensionless quantities including quantity calculus are introduced life history of scientists concerned with measurements units are presented to be inspiring to working metrologists and students. The International System of Units including, Metre Convention Treaty and its various organs including International National of Weights and Measure are described. The realisation of base units is given in detail. Classes of derived units within the SI, units permitted for time to come, units outside SI but used in special fields of measur...

  6. A beam energy measurement system at NIRS-930 cyclotron

    International Nuclear Information System (INIS)

    Hojo, S.; Honma, T.; Sakamoto, Y.; Miyahara, N.; Okada, T.; Komatsu, K.; Tsuji, N.; Yamada, S.

    2005-01-01

    A beam energy measurement system employing a set of capacitive probes has been developed at NIRS-930 cyclotron. Principle of the measurement is applying a modified-TOF method, so that the two proves are installed at one of the straight section in the beam transport line. Usually they are separated about 5.8 m, which is equivalent to the almost final path length of the beam extracted in the cyclotron. In the measurement, two beam signals are superimposed by adjusting a position of the downstream-probe along the beam direction with watching an oscilloscope screen roughly. In order to determine the beam energy accurately the signals are processed by MCA with suitable electric module. (author)

  7. Functional leg length discrepancy between theories and reliable instrumental assessment: a study about newly invented NPoS system.

    Science.gov (United States)

    Mahmoud, Asmaa; Abundo, Paolo; Basile, Luisanna; Albensi, Caterina; Marasco, Morena; Bellizzi, Letizia; Galasso, Franco; Foti, Calogero

    2017-01-01

    In spite the instinct social&financial impact of Leg Length Discrepancy (LLD), controversial and conflicting results still exist regarding a reliable assessment/correction method. For proper management it's essential to discriminate between anatomical&functional Leg Length Discrepancy (FLLD). With the newly invented NPoS (New Postural Solution), under the umbrella of the collaboration of PRM Department, Tor Vergata University with Baro Postural Instruments srl, positive results were observed in both measuring& compensating the hemi-pelvic antero-medial rotation in FLLD through personalized bilateral heel raise using two NPoS components: Foot Image System (FIS) and Postural Optimizer System (POS). This led our research interest to test the validity of NPoS as a preliminary step before evaluating its implementations in postural disorders. After clinical evaluation, 4 subjects with FLLD have been assessed by NPoS. Over a period of 2 months, every subject was evaluated 12 times by two different operators, 48 measurements in total, results have been verified in correlation to BTS GaitLab results. Intra-Operator&inter-operator variability analysis showed statistically insignificant differences, while inter-method variability between NPoS and BTS parameters expressed a linear correlation. Results suggest a significant validity of NPoS in assessment&correction of FLLD, with high degree of reproducibility with minimal operator dependency. This can be considered a base for promising clinical implications of NPoS as a reliable cost effective postural assessment/corrective tool. V.

  8. The algorithm of random length sequences synthesis for frame synchronization of digital television systems

    Directory of Open Access Journals (Sweden)

    Аndriy V. Sadchenko

    2015-12-01

    Full Text Available Digital television systems need to ensure that all digital signals processing operations are performed simultaneously and consistently. Frame synchronization dictated by the need to match phases of transmitter and receiver so that it would be possible to identify the start of a frame. As a frame synchronization signals are often used long length binary sequence with good aperiodic autocorrelation function. Aim: This work is dedicated to the development of the algorithm of random length sequences synthesis. Materials and Methods: The paper provides a comparative analysis of the known sequences, which can be used at present as synchronization ones, revealed their advantages and disadvantages. This work proposes the algorithm for the synthesis of binary synchronization sequences of random length with good autocorrelation properties based on noise generator with a uniform distribution law of probabilities. A "white noise" semiconductor generator is proposed to use as the initial material for the synthesis of binary sequences with desired properties. Results: The statistical analysis of the initial implementations of the "white noise" and synthesized sequences for frame synchronization of digital television is conducted. The comparative analysis of the synthesized sequences with known ones was carried out. The results show the benefits of obtained sequences in compare with known ones. The performed simulations confirm the obtained results. Conclusions: Thus, the search algorithm of binary synchronization sequences with desired autocorrelation properties received. According to this algorithm, the sequence can be longer in length and without length limitations. The received sync sequence can be used for frame synchronization in modern digital communication systems that will increase their efficiency and noise immunity.

  9. Interferometric system with tracking refractometry capability in the measuring axis

    International Nuclear Information System (INIS)

    Lazar, J; Holá, M; Číp, O; Hrabina, J; Oulehla, J

    2013-01-01

    We present a combined interferometric arrangement designed for measurement of one-axis displacement over a specified measuring range with mechanical referencing. This concept allows simultaneous measurement of the carriage position from both sides together with monitoring of the overall range. This can be used in configuration with in-line monitoring of the fluctuations of the refractive index-–tracking refractometry. Similarly, the wavelength of the laser source can be stabilized over the measuring range, effectively compensating for the refractive index changes. Otherwise, monitoring of length of the measuring range can give information about the thermal dilatation effects of frame of the whole measuring setup. This technique can find its way into high-precision positioning systems in nanometrology. (technical design note)

  10. Laser confocal measurement system for curvature radius of lenses based on grating ruler

    Science.gov (United States)

    Tian, Jiwei; Wang, Yun; Zhou, Nan; Zhao, Weirui; Zhao, Weiqian

    2015-02-01

    In the modern optical measurement field, the radius of curvature (ROC) is one of the fundamental parameters of optical lens. Its measurement accuracy directly affects the other optical parameters, such as focal length, aberration and so on, which significantly affect the overall performance of the optical system. To meet the demand of measurement instruments for radius of curvature (ROC) with high accuracy in the market, we develop a laser confocal radius measurement system with grating ruler. The system uses the peak point of the confocal intensity curve to precisely identify the cat-eye and confocal positions and then measure the distance between these two positions by using the grating ruler, thereby achieving the high-precision measurement for the ROC. The system has advantages of high focusing sensitivity and anti-environment disturbance ability. And the preliminary theoretical analysis and experiments show that the measuring repeatability can be up to 0.8 um, which can provide an effective way for the accurate measurement of ROC.

  11. Highly efficient full-length hepatitis C virus genotype 1 (strain TN) infectious culture system

    DEFF Research Database (Denmark)

    Li, Yi-Ping; Ramirez, Santseharay; Jensen, Sanne B

    2012-01-01

    Chronic infection with hepatitis C virus (HCV) is an important cause of end stage liver disease worldwide. In the United States, most HCV-related disease is associated with genotype 1 infection, which remains difficult to treat. Drug and vaccine development was hampered by inability to culture...... full-length TN infection dose-dependently. Given the unique importance of genotype 1 for pathogenesis, this infectious 1a culture system represents an important advance in HCV research. The approach used and the mutations identified might permit culture development for other HCV isolates, thus......) culture systems in Huh7.5 cells. Here, we developed a highly efficient genotype 1a (strain TN) full-length culture system. We initially found that the LSG substitutions conferred viability to an intergenotypic recombinant composed of TN 5' untranslated region (5'UTR)-NS5A and JFH1 NS5B-3'UTR; recovered...

  12. Improvement on a Michelson interferometer for bunch length measurement of a femtosecond accelerator

    International Nuclear Information System (INIS)

    Lin Xuling; Bei Hua; Zhang Jianbing; Dai Zhimin

    2009-01-01

    Based on the femtosecond accelerator facility at Shanghai Institute of Applied Physics (SINAP), a conventional far-infrared Michelson interferometer was built to measure the bunch length by means of optical autocorrelation. However, according to the preliminary experiment result, the resolution of interferometer is not good enough, because the mirror-driving mechanism makes the moving mirror tend to tilt or wobble as it retards. Considering of the allowable errors, we calculate the maximum allowable titling angle of the moving mirror, and discuss the alignment plan in this paper. (authors)

  13. Generation of Length Distribution, Length Diagram, Fibrogram, and Statistical Characteristics by Weight of Cotton Blends

    Directory of Open Access Journals (Sweden)

    B. Azzouz

    2007-01-01

    Full Text Available The textile fibre mixture as a multicomponent blend of variable fibres imposes regarding the proper method to predict the characteristics of the final blend. The length diagram and the fibrogram of cotton are generated. Then the length distribution, the length diagram, and the fibrogram of a blend of different categories of cotton are determined. The length distributions by weight of five different categories of cotton (Egyptian, USA (Pima, Brazilian, USA (Upland, and Uzbekistani are measured by AFIS. From these distributions, the length distribution, the length diagram, and the fibrogram by weight of four binary blends are expressed. The length parameters of these cotton blends are calculated and their variations are plotted against the mass fraction x of one component in the blend .These calculated parameters are compared to those of real blends. Finally, the selection of the optimal blends using the linear programming method, based on the hypothesis that the cotton blend parameters vary linearly in function of the components rations, is proved insufficient.

  14. Screening length in dusty plasma crystals

    International Nuclear Information System (INIS)

    Nikolaev, V S; Timofeev, A V

    2016-01-01

    Particles interaction and value of the screening length in dusty plasma systems are of great interest in dusty plasma area. Three inter-particle potentials (Debye potential, Gurevich potential and interaction potential in the weakly collisional regime) are used to solve equilibrium equations for two dusty particles suspended in a parabolic trap. The inter-particle distance dependence on screening length, trap parameter and particle charge is obtained. The functional form of inter-particle distance dependence on ion temperature is investigated and compared with experimental data at 200-300 K in order to test used potentials applicability to dusty plasma systems at room temperatures. The preference is given to the Yukawa-type potential including effective values of particle charge and screening length. The estimated effective value of the screening length is 5-15 times larger than the Debye length. (paper)

  15. CW Yb:YAG LASER FOR PORTABLE MEASURING SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. M. Ivashko

    2014-01-01

    Full Text Available The theoretical and experimental results of longitudinally continuous-wave diode-pumped Yb:Y3Al5O12 (YAG laser performance for compact field-condition measuring systems were demonstrated. Optimization of laser setup in terms of operation condition in the range of -40 ˚С – +65 ˚С without active thermal stabilization was carried out. Using Yb (10 ат.%:YAG crystal with the length of 3 mm the maximal output power more than 2 W was obtained in the whole of temperature range.

  16. Localization length in a quasi-one-dimensional disordered system in the presence of an electric field

    International Nuclear Information System (INIS)

    Gasparian, Vladimir; Cahay, Marc; Jodar, Esther

    2011-01-01

    A two-dimensional δ-potential Kronig-Penney model for quasi-one-dimensional (Q1D) disordered systems is used to study analytically the influence of a constant electric field on the inverse localization length (LL). Based on the Green's function formalism we have calculated LL as a function of the incoming energy E, electric field F, length L of the Q1D sample, number of modes M in the transverse direction and the amount of disorder w. We show that, for large L in Q1D systems, states are weakly localized, i.e. we deal with power-law localization. With increasing electric field in Q1D mesoscopic systems a transition from exponential to a power-law behavior takes place, as in 1D systems. We note that the graphs showing the inverse LL change significantly with increasing F (for fixed M) rather than with increasing M (for fixed F). We also show that the graphs representing the ratio of the corresponding localization length without and with electric field collapse for all modes M into a universal curve in the Q1D strip model.

  17. Relation of Stump Length with Various Gait Parameters in Trans-tibial Amputee

    Directory of Open Access Journals (Sweden)

    Koyel Majumdar

    2008-07-01

    Full Text Available The purpose of this paper is evaluating the impact of stump length of unilateral below knee amputees (BKA on different gait parameters. Nine unilateral BKA were chosen and divided into three groups comprising patients with short, medium, and long stump length. Each of them underwent gait analysis test by Computer Dynography (CDG system to measure the gait parameters. It was found that the ground reaction force is higher in the patients with medium stump length whereas the velocity, step length both for the prosthetic and sound limb and cadence were high in longer stump length. Statistical analysis shows a significant difference (p<0.05 between the gait parameters of BKA with medium and longer stump length. The patients with longer stump length were more efficient than medium and short stump patients as they consumed comparatively lesser energy while walking with self-selected velocity and conventional (Solid ankle cushioned heel SACH foot.

  18. On the frequency distributions per unit area of the projected and etchable lengths of surface-intersecting fission tracks: influences of track revelation, observation and measurement

    International Nuclear Information System (INIS)

    Jonckheere, R.; Haute, P. van den

    1999-01-01

    In addition to the statistical bounds discussed, thermal history analysis based on the projected and etchable length distributions of surface intersecting fission tracks is limited by systematic factors related to track revelation, observation and measurement. The effects of track revelation, in particular, distort these distributions in the length intervals of interest. An observation threshold poses a problem if it is described by a critical angle θ c , but not if it is described by other criteria proposed in the literature. Measurement imprecisions, predictably, blur the thermal history information contained in these distributions. Measurements of semi-confined tracks, added as a result of surface etching, are a more promising alternative to confined track length measurements for accessing the thermal history record in the fission track length distribution. On the other hand, measurements of the projected lengths of surface intersecting tracks offer the theoretical possibility of determining the true volumetric density N and true mean length m of an arbitrary population of fission tracks, thus allowing direct determination of the corrected age of samples with complex thermal histories. On a methodical level, knowledge of N and m allows to determine the efficiency with which fission tracks are counted under the optical microscope under exactly the same conditions as those under which fission track counts for routine dating purposes are performed

  19. A computerized system to measure interproximal alveolar bone levels in epidemiologic, radiographic investigations. I

    International Nuclear Information System (INIS)

    Wouters, F.R.; Jon-And, C.; Frithiof, L.; Soeder, P.Oe.; Lavstedt, S.

    1988-01-01

    The aims of the study were to adapt a computerized system to epidemiologic conditions, for rapid full-mouth measurements of alveolar bone levels from X5-magnified periapical radiographs and to analyze the variations in measurement due to different system components. Full-mouth measurements of interproximal alveolar bone height in percentage of root and tooth lengths were completed within av average time of 15 min. per set of radiographs. An analysis of variance showed that the examiner variation in measurement of a linear scale distance was 0.02 mm. The measurement accuracy was different for different distances. Each distance (d) measured with this system should therefore be calibrated with the equation Y = -0.007 - 0.014 (log 3d - 1.50) where Y is the estimate of measurement accuracy. The present computerized system enabled rapid recordings and demonstrated good measurement precision and accuracy. These are valuable features in epidemiologic investigations

  20. Tension-referenced measures of gastrocnemius slack length and stiffness in Parkinson's disease.

    Science.gov (United States)

    Tan, Benedict; Double, Kay L; Burne, John; Diong, Joanna

    2016-12-01

    It is not known how passive muscle length and stiffness contribute to rigidity in Parkinson's disease. The objective of this study was to compare passive gastrocnemius muscle-tendon slack length and stiffness at known tension in Parkinson's disease subjects with ankle rigidity and in able-bodied people. Passive ankle torque-angle curves were obtained from 15 Parkinson's disease subjects with rigidity and 15 control subjects. Torque-angle data were used to derive passive gastrocnemius length-tension data and calculate slack length and stiffness of the gastrocnemius muscle. Between-group comparisons were made with linear models. Gastrocnemius muscle-tendon slack lengths (adjusted between-group difference, 0.01 m; 95% CI, -0.02 to 0.04 m; P = 0.37) and stiffness (adjusted between-group difference, 15.7 m -1 ; 95% CI, -8.5 to 39.9 m -1 ; P = 0.19) were not significantly different between groups. Parkinson's disease subjects with ankle rigidity did not have significantly shorter or stiffer gastrocnemius muscles compared with control subjects. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.

  1. Temperature gradient scale length measurement: A high accuracy application of electron cyclotron emission without calibration

    Energy Technology Data Exchange (ETDEWEB)

    Houshmandyar, S., E-mail: houshmandyar@austin.utexas.edu; Phillips, P. E.; Rowan, W. L. [Institute for Fusion Studies, The University of Texas at Austin, Austin, Texas 78712 (United States); Yang, Z. J. [Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Hubbard, A. E.; Rice, J. E.; Hughes, J. W.; Wolfe, S. M. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02129 (United States)

    2016-11-15

    Calibration is a crucial procedure in electron temperature (T{sub e}) inference from a typical electron cyclotron emission (ECE) diagnostic on tokamaks. Although the calibration provides an important multiplying factor for an individual ECE channel, the parameter ΔT{sub e}/T{sub e} is independent of any calibration. Since an ECE channel measures the cyclotron emission for a particular flux surface, a non-perturbing change in toroidal magnetic field changes the view of that channel. Hence the calibration-free parameter is a measure of T{sub e} gradient. B{sub T}-jog technique is presented here which employs the parameter and the raw ECE signals for direct measurement of electron temperature gradient scale length.

  2. Resonance chains in open systems, generalized zeta functions and clustering of the length spectrum

    International Nuclear Information System (INIS)

    Barkhofen, S; Faure, F; Weich, T

    2014-01-01

    In many non-integrable open systems in physics and mathematics, resonances have been found to be surprisingly ordered along curved lines in the complex plane. In this article we provide a unifying approach to these resonance chains by generalizing dynamical zeta functions. By means of a detailed numerical study we show that these generalized zeta functions explain the mechanism that creates the chains of quantum resonance and classical Ruelle resonances for three-disk systems as well as geometric resonances on Schottky surfaces. We also present a direct system-intrinsic definition of the continuous lines on which the resonances are strung together as a projection of an analytic variety. Additionally, this approach shows that the existence of resonance chains is directly related to a clustering of the classical length spectrum on multiples of a base length. Finally, this link is used to construct new examples where several different structures of resonance chains coexist. (paper)

  3. LENGTH-WEIGHT RELATIONSHIP AND CONDITION FACTOR OF ...

    African Journals Online (AJOL)

    Data Collection and Analysis. The measurements of length (cm), weight (g) and the condition factor of individual fish sampled were recorded. The relationship between length and weight of the fish was examined by simple linear regression using WINKS software. The variations in the length-weight represented by 'b' were.

  4. Testing the time-of-flight model for flagellar length sensing.

    Science.gov (United States)

    Ishikawa, Hiroaki; Marshall, Wallace F

    2017-11-07

    Cilia and flagella are microtubule-based organelles that protrude from the surface of most cells, are important to the sensing of extracellular signals, and make a driving force for fluid flow. Maintenance of flagellar length requires an active transport process known as intraflagellar transport (IFT). Recent studies reveal that the amount of IFT injection negatively correlates with the length of flagella. These observations suggest that a length-dependent feedback regulates IFT. However, it is unknown how cells recognize the length of flagella and control IFT. Several theoretical models try to explain this feedback system. We focused on one of the models, the "time-of-flight" model, which measures the length of flagella on the basis of the travel time of IFT protein in the flagellar compartment. We tested the time-of-flight model using Chlamydomonas dynein mutant cells, which show slower retrograde transport speed. The amount of IFT injection in dynein mutant cells was higher than that in control cells. This observation does not support the prediction of the time-of-flight model and suggests that Chlamydomonas uses another length-control feedback system rather than that described by the time-of-flight model. © 2017 Ishikawa and Marshall. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  5. Extended fuel cycle length

    International Nuclear Information System (INIS)

    Bruyere, M.; Vallee, A.; Collette, C.

    1986-09-01

    Extended fuel cycle length and burnup are currently offered by Framatome and Fragema in order to satisfy the needs of the utilities in terms of fuel cycle cost and of overall systems cost optimization. We intend to point out the consequences of an increased fuel cycle length and burnup on reactor safety, in order to determine whether the bounding safety analyses presented in the Safety Analysis Report are applicable and to evaluate the effect on plant licensing. This paper presents the results of this examination. The first part indicates the consequences of increased fuel cycle length and burnup on the nuclear data used in the bounding accident analyses. In the second part of this paper, the required safety reanalyses are presented and the impact on the safety margins of different fuel management strategies is examined. In addition, systems modifications which can be required are indicated

  6. Kidney Length in Normal Korean Children

    International Nuclear Information System (INIS)

    Kim, In One; Cheon, Jung Eun; Lee, Young Seok; Lee, Sun Wha; Kim, Ok Hwa; Kim, Ji Hye; Kim, Hong Dae; Sim, Jung Suk

    2010-01-01

    Renal length offers important information to detect or follow-up various renal diseases. The purpose of this study was to determine the kidney length of normal Korean children in relation to age, height, weight, body surface area (BSA), and body mass index (BMI). Children between 1 month and 15 years of age without urological abnormality were recruited. Children below 3rd percentile and over 97th percentile for height or weight were excluded. Both renal lengths were measured in the prone position three times and then averaged by experienced radiologists. The mean length and standard deviation for each age group was obtained, and regression equation was calculated between renal length and age, weight, height, BSA, and BMI, respectively. Renal length was measured in 550 children. Renal length grows rapidly until 24 month, while the growth rate is reduced thereafter. The regression equation for age is: renal length (mm) = 45.953 + 1.064 x age (month, ≤ 24 months) (R2 = 0.720) or 62.173 + 0.203 x age (months, > 24 months) (R2 = 0.711). The regression equation for height is: renal length (mm) = 24.494 + 0.457 x height (cm) (R2 = 0.894). The regression equation for weight is: renal length (mm) = 38.342 + 2.117 x weight (kg, ≤18 kg) (R2 = 0.852) or 64.498 + 0.646 x weight (kg, > 18 kg) (R2 = 0.651). The regression equation for BSA is: renal length (mm) = 31.622 + 61.363 x BSA (m2, ≤ 0.7) (R2 = 0.857) or 52.717 + 29.959 x BSA (m2, > 0.7) (R2 = 0.715). The regression equation for BMI is: renal length (mm) = 44.474 + 1.163 x BMI (R2 = 0.079). This study provides data on the normal renal length and its association with age, weight, height, BSA and BMI. The results of this study will guide the detection and follow-up of renal diseases in Korean children

  7. The analysis of projected fission track lengths

    International Nuclear Information System (INIS)

    Laslett, G.M.; Galbraith, R.F.; Green, P.F.

    1994-01-01

    This article deals with the question of how features of the thermal history can be estimated from projected track length measurements, i.e. lengths of the remaining parts of tracks that have intersected a surface, projected onto that surface. The appropriate mathematical theory is described and used to provide a sound basis both for understanding the nature of projected length measurements and for analysing observed data. The estimation of thermal history parameters corresponding to the current temperature, the maximum palaeotemperature and the time since cooling, is studied using laboratory data and simulations. In general the information contained in projected track lengths and angles is fairly limited, compared, for example, with that from a much smaller number of confined tracks, though we identify some circumstances when such measurements may be useful. Also it is not straightforward to extract the information and simple ad hoc estimation methods are generally inadequate. (author)

  8. Application of gel dosimetry - A preliminary study on verification of uniformity of activity and length of source used in Beta-Cath system

    International Nuclear Information System (INIS)

    Subramaniam, S.; Rabi Raja Singh, I.; Visalatchi, S.; Paul Ravindran, B.

    2002-01-01

    Recently the intraluminal irradiation of coronary arteries following balloon angioplasty is found to reduce proliferation of smooth muscle cells and restenosis. Among the isotopes used for the intracoronary irradiation, 90 Sr/Y appears to be ideal (H I Almos et al, 1996). In 1984 Gore et al proposed that radiation induced changes in the well-established Fricke solution could be probed with Nuclear Magnetic Resonance (NMR) relaxation measurements rather than using conventional spectrophotometry measurements. This was a major step in the development of gel dosimetry and since then gel dosimetry has been one of the major advances in the dosimetry of complex radiation fields has been in the area of gel dosimetry. In this preliminary work on gel dosimetry we present the verification of uniformity of activity along the length of the source train and verification of the length of the source used in the Beta-Cath system used for intracoronary brachytherapy with ferrous gel dosimeter. The Beta-Cath system obtained from Novoste, Norcross, GA was used in this study. It consists of a source train of 16 90 Sr/Y sources each of length 2.5mm. The total length of the source train is 40mm. For preparation of the Ferrous-Gelatin Gel, the recipe provided by the London Regional Cancer Center, London Ontario, Canada was used. Stock solutions of 50mM H 2 SO 4 , 0.3 mM ferrous ammonium sulphate, 0.05mM Xylenol orange was first prepared. The gel was prepared by mixing 4% gelatin with distilled water while stirring in a water bath at 40-42 deg. C. Acid solution, Ferrous ammonium sulphate solution and Xylenol orange were added and stirred in the water bath for about an hour to allow aeration. The mixture was poured in to three 20ml syringes to form the gel and stored in the refrigerator at 5 deg. C. For irradiation with Beta-Cath, the gel was prepared in three cylindrical 20ml syringes. A nylon tube having the same dimension as that of the delivery catheter used in intra-coronary was placed

  9. Response characteristics of probe-transducer systems for pressure measurements in gas-solid fluidized beds: how to prevent pitfalls in dynamic pressure measurements

    NARCIS (Netherlands)

    Ommen, van J.R.; Schouten, J.C.; Stappen, van der M.L.M.; Bleek, van den C.M.

    1999-01-01

    It is long known already that the pressure probe–transducer systems applied in gas–solid fluidized beds can distort the measured pressure fluctuations. Several rules of thumb have been proposed to determine probe length and internal diameter required to prevent this. Recently, Xie and Geldart [H.-Y.

  10. Morphometric Characteristics and Length-Weight Relationship of Russian Sturgeon Juveniles Fed with Different Ratio

    Directory of Open Access Journals (Sweden)

    Raluca Cristina ANDREI(GURIENCU

    2017-11-01

    Full Text Available The aim of this paper was to analyze some morphometric characteristics and the correlation between them for Russian sturgeon juveniles (Acipenser gueldenstaedtii reared in a recirculating aquaculture system fed at different fed with different ratio: 1% body weight (BW, 1.5% BW, 2% BW and ad libitum feeding (which was around 2.8% BW.Fish, with an average body mass around 248.194 ± 1.59 g. Following biometric measurements were made for each fish, including weight (W, total length (TL, standard length (SL, fork length (FL, maximum body depth (last depth of caudal peduncle, H; preanal distance (AD, predorsal distance (PD, length of head (C, preorbital distance (PO, length of pectoral fin (LPF, interorbital distance (ID, maximum width of head (MH, width of mouth (WM, width of the head at the level of the mouth (WHM. The obtained results showed significant differences between all morphometric measurements (p<0.05 for all the experimental variants, emphasizing that in the ad libitum feeding all morphometric measurements were significantly higher than in the other experimental variants. In order to highlight more eloquent these differences, were developed some linear regressions between the morphometric measurements and significant positive correlation (p<0.05 between dependent and independent variables were found.

  11. Recent high-accuracy measurements of the 1S0 neutron-neutron scattering length

    International Nuclear Information System (INIS)

    Howell, C.R.; Chen, Q.; Gonzalez Trotter, D.E.; Salinas, F.; Crowell, A.S.; Roper, C.D.; Tornow, W.; Walter, R.L.; Carman, T.S.; Hussein, A.; Gibbs, W.R.; Gibson, B.F.; Morris, C.; Obst, A.; Sterbenz, S.; Whitton, M.; Mertens, G.; Moore, C.F.; Whiteley, C.R.; Pasyuk, E.; Slaus, I.; Tang, H.; Zhou, Z.; Gloeckle, W.; Witala, H.

    2000-01-01

    This paper reports two recent high-accuracy determinations of the 1 S 0 neutron-neutron scattering length, a nn . One was done at the Los Alamos National Laboratory using the π - d capture reaction to produce two neutrons with low relative momentum. The neutron-deuteron (nd) breakup reaction was used in other measurement, which was conducted at the Triangle Universities Nuclear Laboratory. The results from the two determinations were consistent with each other and with previous values obtained using the π - d capture reaction. The value obtained from the nd breakup measurements is a nn = -18.7 ± 0.1 (statistical) ± 0.6 (systematic) fm, and the value from the π - d capture experiment is a nn = -18.50 ± 0.05 ± 0.53 fm. The recommended value is a nn = -18.5 ± 0.3 fm. (author)

  12. Measurements of neutron spectrum from stopping-length target irradiated by several tens-MeV/u particles

    Energy Technology Data Exchange (ETDEWEB)

    Meigo, Shin-ichiro; Takada, Hiroshi; Nakashima, Hiroshi; Sasa, Toshinobu [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Tanaka, Susumu; Shin, Kazuo; Ono, Shinji

    1997-03-01

    Using a Time-of-Flight technique, we have measured neutron spectra from stopping-length targets bombarded with 68-MeV protons and 100-MeV {alpha}-particles. The measured spectra were used to validate the results calculated by the Quantum Molecular Dynamics (QMD) plus Statistical Decay Model (SDM). The results of QMD plus SDM code agreed fairly well with the experimental data for the light target. On the other hand, the QMD plus SDM gives a larger value than the experimental for the heavy target. (author)

  13. Direct observation of the edge spin structure and chain length dependence of a finite haldane chain by high field ESR measurements

    International Nuclear Information System (INIS)

    Yoshida, Makoto; Ohta, Hitoshi; Ito, Toshimitsu; Ajiro, Yoshitami

    2006-01-01

    We have performed high field and multi-frequency ESR measurements of finite length S=1 antiferromagnetic chains in Y 2 BaNi 0.96 Mg 0.04 O 5 . Owing to the high spectral resolution by high fields and high frequencies, observed ESR signals can be separated into the contributions of the finite chains with various chain lengths. Our results clearly show that the edge spins actually interact with each other through the quantum spin chain and the interaction depends on the chain length N. (author)

  14. Penile length and circumference: an Indian study.

    Science.gov (United States)

    Promodu, K; Shanmughadas, K V; Bhat, S; Nair, K R

    2007-01-01

    Apprehension about the normal size of penis is a major concern for men. Aim of the present investigation is to estimate the penile length and circumference of Indian males and to compare the results with the data from other countries. Results will help in counseling the patients worried about the penile size and seeking penis enlargement surgery. Penile length in flaccid and stretched conditions and circumference were measured in a group of 301 physically normal men. Erected length and circumference were measured for 93 subjects. Mean flaccid length was found to be 8.21 cm, mean stretched length 10.88 cm and circumference 9.14 cm. Mean erected length was found to be 13.01 cm and erected circumference was 11.46 cm. Penile dimensions are found to be correlated with anthropometric parameters. Insight into the normative data of penile size of Indian males obtained. There are significant differences in the mean penile length and circumference of Indian sample compared to the data reported from other countries. Study need to be continued with a large sample to establish a normative data applicable to the general population.

  15. Musculoskeletal pain and posture decrease step length in young adults

    Directory of Open Access Journals (Sweden)

    Maria Regina Rachmawati

    2009-08-01

    Full Text Available Pain of the musculoskeletal system, especially low back pain, is one of the most frequent problems with a high risk of disability. The aim of this research study was to determine the existence of an association between low back pain on one hand, posture and step length on the other. This cross-sectional study was conducted on 77 healthy young adult subjects. Step length was measured with the Biodex Gait Trainer 2 (230 VAC. The study results indicate that 62.3% of the young adult subjects had suffered from low back pain. There was no significant association between gender and pain. In male subjects no significant association was found between pain on one hand and mean difference in step length and posture on the other. However, in female subjects with abnormal posture, there was a highly significant difference in left step length between subjects with back pain and those without (p=0.007. The results of a multiple regression analysis indicate that posture has the greatest influence on left step length (B=4.135; 95% Confidence Interval 0.292-7.977. It is recommended that in the examination of low back pain an assessment be made of posture, step length and difference in step lengths.

  16. Musculoskeletal pain and posture decrease step length in young adults

    Directory of Open Access Journals (Sweden)

    Maria Regina Rachmawati

    2016-02-01

    Full Text Available Pain of the musculoskeletal system, especially low back pain, is one of the most frequent problems with a high risk of disability. The aim of this research study was to determine the existence of an association between low back pain on one hand,  posture and step length on the other. This cross-sectional study was conducted on 77 healthy young adult subjects. Step length was measured with the Biodex Gait Trainer 2 (230 VAC. The study results indicate that 62.3% of the young adult subjects had suffered from low back pain. There was no significant association between gender and pain. In male subjects no significant association was found between pain on one hand and mean difference in step length and posture on the other. However, in female subjects with abnormal posture, there was a highly significant difference in left step length between subjects with back pain and those without (p=0.007.  The results of a multiple regression analysis indicate that posture has the greatest influence on left step length (B=4.135; 95% Confidence Interval 0.292-7.977. It is recommended that in the examination of low back pain an assessment be made of posture, step length and difference in step lengths.

  17. Pulp regeneration in a full-length human tooth root using a hierarchical nanofibrous microsphere system.

    Science.gov (United States)

    Li, Xiangwei; Ma, Chi; Xie, Xiaohua; Sun, Hongchen; Liu, Xiaohua

    2016-04-15

    While pulp regeneration using tissue engineering strategy has been explored for over a decade, successful regeneration of pulp tissues in a full-length human root with a one-end seal that truly simulates clinical endodontic treatment has not been achieved. To address this challenge, we designed and synthesized a unique hierarchical growth factor-loaded nanofibrous microsphere scaffolding system. In this system, vascular endothelial growth factor (VEGF) binds with heparin and is encapsulated in heparin-conjugated gelatin nanospheres, which are further immobilized in the nanofibers of an injectable poly(l-lactic acid) (PLLA) microsphere. This hierarchical microsphere system not only protects the VEGF from denaturation and degradation, but also provides excellent control of its sustained release. In addition, the nanofibrous PLLA microsphere integrates the extracellular matrix-mimicking architecture with a highly porous injectable form, efficiently accommodating dental pulp stem cells (DPSCs) and supporting their proliferation and pulp tissue formation. Our in vivo study showed the successful regeneration of pulp-like tissues that fulfilled the entire apical and middle thirds and reached the coronal third of the full-length root canal. In addition, a large number of blood vessels were regenerated throughout the canal. For the first time, our work demonstrates the success of pulp tissue regeneration in a full-length root canal, making it a significant step toward regenerative endodontics. The regeneration of pulp tissues in a full-length tooth root canal has been one of the greatest challenges in the field of regenerative endodontics, and one of the biggest barriers for its clinical application. In this study, we developed a unique approach to tackle this challenge, and for the first time, we successfully regenerated living pulp tissues in a full-length root canal, making it a significant step toward regenerative endodontics. This study will make positive scientific

  18. Information content versus word length in random typing

    International Nuclear Information System (INIS)

    Ferrer-i-Cancho, Ramon; Moscoso del Prado Martín, Fermín

    2011-01-01

    Recently, it has been claimed that a linear relationship between a measure of information content and word length is expected from word length optimization and it has been shown that this linearity is supported by a strong correlation between information content and word length in many languages (Piantadosi et al 2011 Proc. Nat. Acad. Sci. 108 3825). Here, we study in detail some connections between this measure and standard information theory. The relationship between the measure and word length is studied for the popular random typing process where a text is constructed by pressing keys at random from a keyboard containing letters and a space behaving as a word delimiter. Although this random process does not optimize word lengths according to information content, it exhibits a linear relationship between information content and word length. The exact slope and intercept are presented for three major variants of the random typing process. A strong correlation between information content and word length can simply arise from the units making a word (e.g., letters) and not necessarily from the interplay between a word and its context as proposed by Piantadosi and co-workers. In itself, the linear relation does not entail the results of any optimization process. (letter)

  19. Determination of {pi}{pi} scattering lengths from measurement of {pi}{sup +{pi}-} atom lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B. [Santiago de Compostela University (Spain); Afanasyev, L. [JINR Dubna (Russian Federation); Benayoun, M. [LPNHE des Universites Paris VI/VII, IN2P3-CNRS (France); Benelli, A. [Zurich University (Switzerland); Berka, Z. [Czech Technical University in Prague, Prague (Czech Republic); Brekhovskikh, V. [IHEP Protvino (Russian Federation); Caragheorgheopol, G. [IFIN-HH, National Institute for Physics and Nuclear Engineering, Bucharest (Romania); Cechak, T. [Czech Technical University in Prague, Prague (Czech Republic); Chiba, M. [Tokyo Metropolitan University (Japan); Chliapnikov, P.V. [IHEP Protvino (Russian Federation); Ciocarlan, C.; Constantinescu, S. [IFIN-HH, National Institute for Physics and Nuclear Engineering, Bucharest (Romania); Costantini, S. [Basel University (Switzerland); Curceanu, C. [IFIN-HH, National Institute for Physics and Nuclear Engineering, Bucharest (Romania); Doskarova, P. [Czech Technical University in Prague, Prague (Czech Republic); Dreossi, D. [INFN, Sezione di Trieste and Trieste University, Trieste (Italy); Drijard, D., E-mail: Daniel.Drijard@cern.ch [CERN, Geneva (Switzerland); Dudarev, A. [JINR Dubna (Russian Federation); Ferro-Luzzi, M. [CERN, Geneva (Switzerland); Fungueirino Pazos, J.L. [Santiago de Compostela University (Spain)

    2011-10-05

    The DIRAC experiment at CERN has achieved a sizeable production of {pi}{sup +{pi}-} atoms and has significantly improved the precision on its lifetime determination. From a sample of 21 227 atomic pairs, a 4% measurement of the S-wave {pi}{pi} scattering length difference |a{sub 0}-a{sub 2}|=(0.2533{sub -0.0078}{sup +0.0080}|{sub stat}{sup +0.0078}{sub -0.0073}|{sub syst})M{sub {pi}}{sup +-1} has been attained, providing an important test of Chiral Perturbation Theory.

  20. [Ultrasonographic evaluation of the uterine cervix length remaining after LOOP-excision].

    Science.gov (United States)

    Robert, A-L; Nicolas, F; Lavoué, V; Henno, S; Mesbah, H; Porée, P; Levêque, J

    2014-04-01

    To assess whether there is a correlation between the length of a conization specimen and the length of the cervix measured by vaginal ultrasonography after the operation Prospective observational study including patients less than 45 years with measurement of cervical length before and the day of the conization, and measuring the histological length of the specimen. Among the 40 patients enrolled, the average ultrasound measurements before conization was 26.9 mm (± 4.9 mm) against 18.1mm (± 4.4mm) after conization with a mean difference of 8.8mm (± 2.4mm) (difference statistically significant Pcervix length remove by loop-excision in our series is 33% (± 8.5%). A good correlation between the measurements of the specimen and the cervical ultrasound length before and after conization was found, as a significant reduction in cervical length after conization. The precise length of the specimen should be known in case of pregnancy and the prevention of prematurity due to conization rests on selected indications and efficient surgical technique. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Information-theoretic lengths of Jacobi polynomials

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero, A; Dehesa, J S [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, Granada (Spain); Sanchez-Moreno, P, E-mail: agmartinez@ugr.e, E-mail: pablos@ugr.e, E-mail: dehesa@ugr.e [Instituto ' Carlos I' de Fisica Teorica y Computacional, Universidad de Granada, Granada (Spain)

    2010-07-30

    The information-theoretic lengths of the Jacobi polynomials P{sup ({alpha}, {beta})}{sub n}(x), which are information-theoretic measures (Renyi, Shannon and Fisher) of their associated Rakhmanov probability density, are investigated. They quantify the spreading of the polynomials along the orthogonality interval [- 1, 1] in a complementary but different way as the root-mean-square or standard deviation because, contrary to this measure, they do not refer to any specific point of the interval. The explicit expressions of the Fisher length are given. The Renyi lengths are found by the use of the combinatorial multivariable Bell polynomials in terms of the polynomial degree n and the parameters ({alpha}, {beta}). The Shannon length, which cannot be exactly calculated because of its logarithmic functional form, is bounded from below by using sharp upper bounds to general densities on [- 1, +1] given in terms of various expectation values; moreover, its asymptotics is also pointed out. Finally, several computational issues relative to these three quantities are carefully analyzed.

  2. Investigations on quantum mechanics with minimal length

    International Nuclear Information System (INIS)

    Chargui, Yassine

    2009-01-01

    We consider a modified quantum mechanics where the coordinates and momenta are assumed to satisfy a non-standard commutation relation of the form( X i , P j ) = iℎ(δ ij (1+βP 2 )+β'P i P j ). Such an algebra results in a generalized uncertainty relation which leads to the existence of a minimal observable length. Moreover, it incorporates an UV/IR mixing and non commutative position space. We analyse the possible representations in terms of differential operators. The latter are used to study the low energy effects of the minimal length by considering different quantum systems : the harmonic oscillator, the Klein-Gordon oscillator, the spinless Salpeter Coulomb problem, and the Dirac equation with a linear confining potential. We also discuss whether such effects are observable in precision measurements on a relativistic electron trapped in strong magnetic field.

  3. Prediction of preterm birth in multiple pregnancies: development of a multivariable model including cervical length measurement at 16 to 21 weeks' gestation.

    Science.gov (United States)

    van de Mheen, Lidewij; Schuit, Ewoud; Lim, Arianne C; Porath, Martina M; Papatsonis, Dimitri; Erwich, Jan J; van Eyck, Jim; van Oirschot, Charlotte M; Hummel, Piet; Duvekot, Johannes J; Hasaart, Tom H M; Groenwold, Rolf H H; Moons, Karl G M; de Groot, Christianne J M; Bruinse, Hein W; van Pampus, Maria G; Mol, Ben W J

    2014-04-01

    To develop a multivariable prognostic model for the risk of preterm delivery in women with multiple pregnancy that includes cervical length measurement at 16 to 21 weeks' gestation and other variables. We used data from a previous randomized trial. We assessed the association between maternal and pregnancy characteristics including cervical length measurement at 16 to 21 weeks' gestation and time to delivery using multivariable Cox regression modelling. Performance of the final model was assessed for the outcomes of preterm and very preterm delivery using calibration and discrimination measures. We studied 507 women, of whom 270 (53%) delivered models for preterm and very preterm delivery had a c-index of 0.68 (95% CI 0.63 to 0.72) and 0.68 (95% CI 0.62 to 0.75), respectively, and showed good calibration. In women with a multiple pregnancy, the risk of preterm delivery can be assessed with a multivariable model incorporating cervical length and other predictors.

  4. Temporal characterization of FEL micropulses as function of cavity length detuning using frequency-resolved optical gating

    Energy Technology Data Exchange (ETDEWEB)

    Richman, B.A. [Stanford Univ., CA (United States); DeLong, K.W.; Trebino, R. [Sandia National Lab., Livermore, CA (United States)

    1995-12-31

    Results of frequency resolved optical gating (FROG) measurements on the Stanford mid-IR FEL system show the effect of FEL cavity length detuning on the micropulse temporal structure. The FROG technique enables the acquisition of complete and uniquely invertible amplitude and phase temporal dependence of optical pulses. Unambiguous phase and amplitude profiles are recovered from the data. The optical pulses are nearly transform limited, and the pulse length increases with cavity length detuning.

  5. Evaluating Multispectral Snowpack Reflectivity With Changing Snow Correlation Lengths

    Science.gov (United States)

    Kang, Do Hyuk; Barros, Ana P.; Kim, Edward J.

    2016-01-01

    This study investigates the sensitivity of multispectral reflectivity to changing snow correlation lengths. Matzler's ice-lamellae radiative transfer model was implemented and tested to evaluate the reflectivity of snow correlation lengths at multiple frequencies from the ultraviolet (UV) to the microwave bands. The model reveals that, in the UV to infrared (IR) frequency range, the reflectivity and correlation length are inversely related, whereas reflectivity increases with snow correlation length in the microwave frequency range. The model further shows that the reflectivity behavior can be mainly attributed to scattering rather than absorption for shallow snowpacks. The largest scattering coefficients and reflectivity occur at very small correlation lengths (approximately 10(exp -5 m) for frequencies higher than the IR band. In the microwave range, the largest scattering coefficients are found at millimeter wavelengths. For validation purposes, the ice-lamella model is coupled with a multilayer snow physics model to characterize the reflectivity response of realistic snow hydrological processes. The evolution of the coupled model simulated reflectivities in both the visible and the microwave bands is consistent with satellite-based reflectivity observations in the same frequencies. The model results are also compared with colocated in situ snow correlation length measurements (Cold Land Processes Field Experiment 2002-2003). The analysis and evaluation of model results indicate that the coupled multifrequency radiative transfer and snow hydrology modeling system can be used as a forward operator in a data-assimilation framework to predict the status of snow physical properties, including snow correlation length.

  6. An ancient relation between units of length and volume based on a sphere.

    Directory of Open Access Journals (Sweden)

    Elena Zapassky

    Full Text Available The modern metric system defines units of volume based on the cube. We propose that the ancient Egyptian system of measuring capacity employed a similar concept, but used the sphere instead. When considered in ancient Egyptian units, the volume of a sphere, whose circumference is one royal cubit, equals half a hekat. Using the measurements of large sets of ancient containers as a database, the article demonstrates that this formula was characteristic of Egyptian and Egyptian-related pottery vessels but not of the ceramics of Mesopotamia, which had a different system of measuring length and volume units.

  7. Electron critical gradient scale length measurements of ICRF heated L-mode plasmas at Alcator C-Mod tokamak

    Science.gov (United States)

    Houshmandyar, S.; Hatch, D. R.; Horton, C. W.; Liao, K. T.; Phillips, P. E.; Rowan, W. L.; Zhao, B.; Cao, N. M.; Ernst, D. R.; Greenwald, M.; Howard, N. T.; Hubbard, A. E.; Hughes, J. W.; Rice, J. E.

    2018-04-01

    A profile for the critical gradient scale length (Lc) has been measured in L-mode discharges at the Alcator C-Mod tokamak, where electrons were heated by an ion cyclotron range of frequency through minority heating with the intention of simultaneously varying the heat flux and changing the local gradient. The electron temperature gradient scale length (LTe-1 = |∇Te|/Te) profile was measured via the BT-jog technique [Houshmandyar et al., Rev. Sci. Instrum. 87, 11E101 (2016)] and it was compared with electron heat flux from power balance (TRANSP) analysis. The Te profiles were found to be very stiff and already above the critical values, however, the stiffness was found to be reduced near the q = 3/2 surface. The measured Lc profile is in agreement with electron temperature gradient (ETG) models which predict the dependence of Lc-1 on local Zeff, Te/Ti, and the ratio of the magnetic shear to the safety factor. The results from linear Gene gyrokinetic simulations suggest ETG to be the dominant mode of turbulence in the electron scale (k⊥ρs > 1), and ion temperature gradient/trapped electron mode modes in the ion scale (k⊥ρs < 1). The measured Lc profile is in agreement with the profile of ETG critical gradients deduced from Gene simulations.

  8. Simultaneous measurement of focal length and index of refraction of a microlens using a compound microscope

    International Nuclear Information System (INIS)

    Chollet, Franck; Ashraf, Mohammed

    2009-01-01

    The fabrication of microlenses has spurred a lot of interest and resulted in multiple techniques of fabrication in the past decade. However the metrology of these lenses has received less attention and remains a complex and time-consuming task that does not allow frequent control during development and manufacturing. We propose a simple technique based on a standard compound microscope that would allow measuring the focal length of a plano-convex lens and at the same time obtain a measure of the index of refraction of the lens material. The method relies on observing the different images of an object placed in the illumination path of the microscope. Among these images, some are created by the light going through the lens and others by its reflection on the surface. We show that with the image distance and size it is possible to retrieve the focal length and the average index of refraction of the lens material in the case of quasi-spherical lenses. The accuracy obtained by the technique is better than a few per cent and its cost is negligible as it only uses existing equipment

  9. Safety analysis report for packaging onsite long-length contaminated equipment transport system

    International Nuclear Information System (INIS)

    McCormick, W.A.

    1997-01-01

    This safety analysis report for packaging describes the components of the long-length contaminated equipment (LLCE) transport system (TS) and provides the analyses, evaluations, and associated operational controls necessary for the safe use of the LLCE TS on the Hanford Site. The LLCE TS will provide a standardized, comprehensive approach for the disposal of approximately 98% of LLCE scheduled to be removed from the 200 Area waste tanks

  10. Safety analysis report for packaging, onsite, long-length contaminated equipment transport system

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, W.A.

    1997-05-09

    This safety analysis report for packaging describes the components of the long-length contaminated equipment (LLCE) transport system (TS) and provides the analyses, evaluations, and associated operational controls necessary for the safe use of the LLCE TS on the Hanford Site. The LLCE TS will provide a standardized, comprehensive approach for the disposal of approximately 98% of LLCE scheduled to be removed from the 200 Area waste tanks.

  11. Sizing Up the Milky Way: A Bayesian Mixture Model Meta-analysis of Photometric Scale Length Measurements

    Science.gov (United States)

    Licquia, Timothy C.; Newman, Jeffrey A.

    2016-11-01

    The exponential scale length (L d ) of the Milky Way’s (MW’s) disk is a critical parameter for describing the global physical size of our Galaxy, important both for interpreting other Galactic measurements and helping us to understand how our Galaxy fits into extragalactic contexts. Unfortunately, current estimates span a wide range of values and are often statistically incompatible with one another. Here, we perform a Bayesian meta-analysis to determine an improved, aggregate estimate for L d , utilizing a mixture-model approach to account for the possibility that any one measurement has not properly accounted for all statistical or systematic errors. Within this machinery, we explore a variety of ways of modeling the nature of problematic measurements, and then employ a Bayesian model averaging technique to derive net posterior distributions that incorporate any model-selection uncertainty. Our meta-analysis combines 29 different (15 visible and 14 infrared) photometric measurements of L d available in the literature; these involve a broad assortment of observational data sets, MW models and assumptions, and methodologies, all tabulated herein. Analyzing the visible and infrared measurements separately yields estimates for L d of {2.71}-0.20+0.22 kpc and {2.51}-0.13+0.15 kpc, respectively, whereas considering them all combined yields 2.64 ± 0.13 kpc. The ratio between the visible and infrared scale lengths determined here is very similar to that measured in external spiral galaxies. We use these results to update the model of the Galactic disk from our previous work, constraining its stellar mass to be {4.8}-1.1+1.5× {10}10 M ⊙, and the MW’s total stellar mass to be {5.7}-1.1+1.5× {10}10 M ⊙.

  12. Failure Mode and Effects Analysis (FMEA) of the solid state full length rod control system

    International Nuclear Information System (INIS)

    Shopsky, W.E.

    1977-01-01

    The Full Length Rod Control System (FLRCS) controls the power to the rod drive mechanisms for rod movement in response to signals received from the Reactor Control System or from signals generated through Reactor Operator action. Rod movement is used to control reactivity of the reactor during plant operation. The Full Length Rod Control System is designed to perform its reactivity control function in conjunction with the Reactor Control and Protection System, to maintain the reactor core within design safety limits. By the use of a Failure Mode and Effects Analysis, it is shown that the FLRCS will perform its reactivity control functions considering the loss of single active components. That is, sufficient fault limiting control circuits are provided which blocks control rod movement and/or indicates presence of a fault condition at the Control Board. Reactor operator action or automatic reactor trip will thus mitigate the consequences of potential failure of the FLRCS. The analysis also qualitatively demonstrates the reliability of the FLRCS to perform its intended function

  13. Topology optimization of a flexible multibody system with variable-length bodies described by ALE–ANCF

    DEFF Research Database (Denmark)

    Sun, Jialiang; Tian, Qiang; Hu, Haiyan

    2018-01-01

    Recent years have witnessed the application of topology optimization to flexible multibody systems (FMBS) so as to enhance their dynamic performances. In this study, an explicit topology optimization approach is proposed for an FMBS with variable-length bodies via the moving morphable components...... (MMC). Using the arbitrary Lagrangian–Eulerian (ALE) formulation, the thin plate elements of the absolute nodal coordinate formulation (ANCF) are used to describe the platelike bodies with variable length. For the thin plate element of ALE–ANCF, the elastic force and additional inertial force, as well...

  14. Modeling and simulating two cut-to-length harvesting systems in central Appalachian hardwoods

    Science.gov (United States)

    Jingxin Wang; Chris B. LeDoux; Yaoxiang Li

    2003-01-01

    The production rates and costs of two cut-to-length harvesting systems was simulated using a modular ground-based simulation model and stand yield data from fully stocked, second growth even aged central Appalachian hardwood forests. The two harvesters simulated were a modified John Deere 988 tracked excavator with a model RP 1600 single grip sawhead and an excavator...

  15. Application of a Low-Energy Electron Beam as a Tool for ultrashort bunch length measurement in circular machines

    CERN Document Server

    Nikiforov, D A; Malyutin, D; Matveenko, A; Rusinov, K; Starostenko, A A

    2017-01-01

    A new diagnostic device designed for non-destructive ultrashort bunch length measurement is described. The operating principle of the device and the measuring technique are described. The possible scheme of arrangement of the device elements are described. The results of simulations of EBP application for different beams under investigation are presented. The quality requirements of the low energy testing beam are considered and resolving detector ability is determined.

  16. A method to measure the antikaon-nucleon scattering length in lattice QCD

    International Nuclear Information System (INIS)

    Lage, Michael; Meissner, Ulf-G.; Rusetsky, Akaki

    2009-01-01

    We propose a method to determine the isoscalar K-bar N scattering length on the lattice. Our method represents the generalization of Luescher's approach in the presence of inelastic channels (complex scattering length). In addition, the proposed approach allows one to find the position of the S-matrix pole corresponding the Λ(1405) resonance.

  17. Upper bound for the length of commutative algebras

    International Nuclear Information System (INIS)

    Markova, Ol'ga V

    2009-01-01

    By the length of a finite system of generators for a finite-dimensional associative algebra over an arbitrary field one means the least positive integer k such that the words of length not exceeding k span this algebra (as a vector space). The maximum length for the systems of generators of an algebra is referred to as the length of the algebra. In the present paper, an upper bound for the length of a commutative algebra in terms of a function of two invariants of the algebra, the dimension and the maximal degree of the minimal polynomial for the elements of the algebra, is obtained. As a corollary, a formula for the length of the algebra of diagonal matrices over an arbitrary field is obtained. Bibliography: 8 titles.

  18. Optical 'dampening' of the refractive error to axial length ratio: implications for outcome measures in myopia control studies.

    Science.gov (United States)

    Cruickshank, Fiona E; Logan, Nicola S

    2018-05-01

    To gauge the extent to which differences in the refractive error axial length relationship predicted by geometrical optics are observed in actual refractive/biometric data. This study is a retrospective analysis of existing data. Right eye refractive error [RX] and axial length [AXL] data were collected on 343 6-to-7-year-old children [mean 7.18 years (S.D. 0.35)], 294 12-to-13-year-old children [mean 13.12 years (S.D. 0.32)] and 123 young adults aged 18-to-25-years [mean 20.56 years (S.D. 1.91)]. Distance RX was measured with the Shin-Nippon NVision-K 5001 infrared open-field autorefractor. Child participants were cyclopleged prior to data collection (1% Cyclopentolate Hydrochloride). Myopia was defined as a mean spherical equivalent [MSE] ≤-0.50 D. Axial length was measured using the Zeiss IOLMaster 500. Optical modelling was based on ray tracing and manipulation of parameters of a Gullstrand reduced model eye. There was a myopic shift in mean MSE with age (6-7 years +0.87 D, 12-13 years -0.06 D and 18-25 years -1.41 D), associated with an increase in mean AXL (6-7 years 22.70 mm, 12-13 years 23.49 mm and 18-25 years 23.98 mm). There was a significant negative correlation between MSE and AXL for all age groups (all p theory predicts that there will be a reduction in the RX: AXL ratio with longer eyes. The participant data although adhering to this theory show a reduced effect, with eyes with longer axial lengths having a lower refractive error to axial length ratio than predicted by model eye calculations. We propose that in myopia control intervention studies when comparing efficacy, consideration should be given to the dampening effect seen with a longer eye. © 2018 The Authors. Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.

  19. A study of topological quantum phase transition and Majorana localization length for the interacting helical liquid system

    International Nuclear Information System (INIS)

    Dey, Dayasindhu; Saha, Sudip Kumar; Deo, P. Singha; Kumar, Manoranjan; Sarkar, Sujit

    2017-01-01

    We study the topological quantum phase transition and also the nature of this transition using the density matrix renormalization group method. We observe the existence of topological quantum phase transition for repulsive interaction, however this phase is more stable for the attractive interaction. The length scale dependent study shows many new and important results and we show explicitly that the major contribution to the excitation comes from the edge of the system when the system is in the topological state. We also show the dependence of Majorana localization length for various values of chemical potential. (author)

  20. Evaluation of Efficient Line Lengths for Better Readability

    Directory of Open Access Journals (Sweden)

    Zahid Hussain

    2012-01-01

    Full Text Available In this paper the major findings of a formal experiment about onscreen text line lengths are presented. The experiment examined the effects of four different line lengths on the reading speed and the reading efficiency. Efficiency is defined as a combination of reading speed and accuracy. Sixteen people between the age of 24 and 36 participated at the experiment. The subjects had to read four different texts with an average line length around 2000 characters. The texts contained substitution words, which had to be detected by the subjects to measure reading accuracy. Besides objective measures like reading speed and accuracy, the subjects were asked to subjectively vote on their reading experience. The results from our objective measures show strong similarities to those of the work done previously by different researchers. The absolute reading speed grows when the line length grows from CPL (Characters Per Line 30-120. The measured reading efficiency, however, doesn\\\\\\'t grow steadily, although a growing trend can be seen. This is due to the fact, that the test persons found in average more substitution words from the 60 CPL text than they did from the 30 and 90 CPL texts. The reading speed seems to increase while the line length increases but the overall comprehension seems to peak at medium line lengths. As in the previous studies, our test persons also prefer the medium (60 and 90 CPL line lengths, although they perform better when reading longer lines. In the overall subjective opinion 13 out of 16 test persons selected the 60 or 90 CPL line length as their favorite. The literature doesn\\\\\\'t truly provide a scientific explanation for the difference between the objective performance and the subjective preference. A natural hypothesis would be that the line length that is the fastest to read would also feel most comfortable to the readers but in the light of this and the earlier research it seems like this is not the case.

  1. Reflective optical system for time-resolved electron bunch measurements at PITZ

    Energy Technology Data Exchange (ETDEWEB)

    Rosbach, K; Baehr, J [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Roensch-Schulenburg, J [Hamburg Univ. (Germany). Inst. fuer Experimentalphysik

    2011-01-15

    The Photo-Injector Test facility at DESY, Zeuthen site (PITZ), produces pulsed electron beams with low transverse emittance and is equipped with diagnostic devices for measuring various electron bunch properties, including the longitudinal and transverse electron phase space distributions. The longitudinal bunch structure is recorded using a streak camera located outside the accelerator tunnel, connected to the diagnostics in the beam-line stations by an optical system of about 30 m length. This system mainly consists of telescopes of achromatic lenses, which transport the light pulses and image them onto the entrance slit of the streak camera. Due to dispersion in the lenses, the temporal resolution degrades during transport. This article presents general considerations for time-resolving optical systems as well as simulations and measurements of specific candidate systems. It then describes the development of an imaging system based on mirror telescopes which will improve the temporal resolution, with an emphasis on off-axis parabolic mirror systems working at unit magnification. A hybrid system of lenses and mirrors will serve as a proof of principle. (orig.)

  2. Measurement of electron beam bunch phase length by rectangular cavities

    International Nuclear Information System (INIS)

    Afanas'ev, V.D.; Rudychev, V.G.; Ushakov, V.I.

    1976-01-01

    An analysis of a phase length of electron bunches with the help of crossed rectangular resonators with the Hsub(102) oscillation type has been made. It has been shown that the electron coordinates after the duplex resonator are described by an ellipse equation for a non-modulated beam. An influence of the initial energy spread upon the electron motion has been studied. It has been ascertained that energy modulation of the electron beam results in displacement of each electron with respect to the ellipse which is proportional to modulation energy, i.e. an error in determination of the phase length of an electron bunch is proportional to the beam energy spread. Relations have been obtained which enable to find genuine values of phases of the analyzed electrons with an accuracy up to linear multipliers

  3. The influence of spring length on the physical parameters of simple harmonic motion

    International Nuclear Information System (INIS)

    Triana, C A; Fajardo, F

    2012-01-01

    The aim of this work is to analyse the influence of spring length on the simple harmonic motion of a spring-mass system. In particular, we study the effect of changing the spring length on the elastic constant k, the angular frequency ω and the damping factor γ of the oscillations. To characterize the behaviour of these variables we worked with a series of springs of seven different lengths, in which the elastic constant was found by means of the spring-elongation measurement and ω was obtained from the measurement of the oscillation period T of a suspended mass. The oscillatory movement was recorded using a force sensor and the γ value was determined by the fit of the envelope oscillations. Graphical analysis of the results shows that k, ω and γ decrease when the natural spring length increases. This experiment can be performed with equipment normally found in undergraduate physics laboratories. In addition, through graphical analysis students can deduce some relationships between variables that determine the simple harmonic motion behaviour. (paper)

  4. Measurement report on the LHC injection kicker ripple denition and maximum pulse length (MD 1268)

    CERN Document Server

    Bartmann, Wolfgang; Kotzian, Gerd; Stoel, Linda; Velotti, Francesco Maria; Vlachodimitropoulos, Vasileios; Wiesner, Christoph; CERN. Geneva. ATS Department

    2016-01-01

    The present LHC lling scheme uses a batch spacing which corresponds to the design report specication of the injection kicker rise time. A reduction of the batch spacing can be directly used to increase luminosity without detrimental eect on beam stability. Therefore, measurements were performed to understand if a tighter batch spacing would lead to increased injection oscillations of a the rst and last bunches of a bunch train and eventually also a growth of the transverse emittance. The results of theses measurement were used to dene the minimum possible batch spacing for an acceptable emittance growth. Another measurement was performed to test if a batch consisting of 320 bunches can be injected instead of the nominal 288 bunch trains. This bunch train is dierently produced in the LHC injectors and features an optimum between beam stability and luminosity gain. The pulse length of the injection kicker was measured to ensure the full batch can be injected at once.

  5. Fundamental length and relativistic length

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1988-01-01

    It si noted that the introduction of fundamental length contradicts the conventional representations concerning the contraction of the longitudinal size of fast-moving objects. The use of the concept of relativistic length and the following ''elongation formula'' permits one to solve this problem

  6. Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system.

    Science.gov (United States)

    Krajczár, Károly; Varga, Enikő; Marada, Gyula; Jeges, Sára; Tóth, Vilmos

    2016-04-01

    The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the mesiobuccal root canal to the working length, and after preparation with #25, #30 and #40 files. Working lenght changes were detected with measurements between the radiological apex and the instrument tips. In the Mtwo group a difference in the working competency (protary files. Mtwo NiTi rotary file did therefore proved to be more accurate in comparison to the conventional hand instrumentation. Working length, Mtwo, nickel-titanium, hand preparation, engine driven preparation.

  7. Energy measurement using a resonator based time-of-flight system

    International Nuclear Information System (INIS)

    Pardo, R.C.; Clifft, B.; Johnson, K.W.; Lewis, R.N.

    1983-01-01

    A resonant pick-up time-of-flight system has been developed for the precise measurement of beam energy at the Argonne Tandem-Linac Accelerator System (ATLAS). The excellent timing characteristics available with ATLAS beams make it desirable to design the beam transport system to be isochronous. The advantages of the resonant time-of-flight system over other energy analysis systems such as the dispersive magnet system are numerous. The system is non-interceptive and non-destructive and preserves the beam phase space. It is non-dispersive. Path length variations are not introduced into the beam which would reduce the timing resolution. It has a large signal-to-noise ratio when compared to non-resonant beam pick-up techniques. It provides the means to precisely set the linac energy and potentially to control the energy in a feedback loop. Finally, the resonant pick-up time-of-flight system is less expensive than an equivalent magnetic system. It consists of two beam-excited resonators, associated electronics to decode the information, a computer interface to the linac PDP 11/34 control computer, and software to analyze the information and deduce the measured beam energy. This report describes the system and its components and gives a schematic overview

  8. Effects of fine root length density and root biomass on soil preferential flow in forest ecosystems

    Directory of Open Access Journals (Sweden)

    Yinghu Zhang

    2015-04-01

    Full Text Available Aim of study: The study was conducted to characterize the impacts of plant roots systems (e.g., root length density and root biomass on soil preferential flow in forest ecosystems. Area of study: The study was carried out in Jiufeng National Forest Park, Beijing, China. Material and methods: The flow patterns were measured by field dye tracing experiments. Different species (Sophora japonica Linn,Platycladus orientalis Franco, Quercus dentata Thunbwere quantified in two replicates, and 12 soil depth were applied. Plant roots were sampled in the sieving methods. Root length density and root biomass were measured by WinRHIZO. Dye coverage was implied in the image analysis, and maximum depth of dye infiltration by direct measurement. Main results: Root length density and root biomass decreased with the increasing distance from soil surface, and root length density was 81.6% higher in preferential pathways than in soil matrix, and 66.7% for root biomass with respect to all experimental plots. Plant roots were densely distributed in the upper soil layers. Dye coverage was almost 100% in the upper 5-10 cm, but then decreased rapidly with soil depth. Root length density and root biomass were different from species: Platycladus orientalis Franco > Quercus dentata Thunb > Sophora japonica Linn. Research highlights: The results indicated that fine roots systems had strong effects on soil preferential flow, particularly root channels enhancing nutrition transport across soil profiles in forest dynamics.

  9. Development of Real-Time Thickness Measuring System for Insulated Pipeline Using Gamma-ray

    International Nuclear Information System (INIS)

    Jang, Ji Hoon; Kim, Byung Joo; Cho, Kyung Shik; Kim, Gi Dong

    2002-01-01

    By this study, on-line real-time radiometric system was developed using a 64 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses an Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer through cable. This system collects and analyses the data from the detector array in real-time as the crawler travels over the piping system. The maximum measurable length of pipe is 120cm/min. in the case of 1mm scanning interval

  10. The effects of social status on biological aging as measured by white-blood-cell telomere length.

    Science.gov (United States)

    Cherkas, L F; Aviv, A; Valdes, A M; Hunkin, J L; Gardner, J P; Surdulescu, G L; Kimura, M; Spector, T D

    2006-10-01

    Low socio-economic status (SES) is associated with a shortened life expectancy, but its effect on aging is unknown. The rate of white-blood-cell (WBC) telomere attrition may be a biological indicator of human aging. We tested the hypothesis that SES is associated with telomere attrition independent of known risk factors influencing the aging process. We studied 1552 female twins. A venous blood sample was taken from each twin and isolated WBCs used for extraction of DNA. Terminal restriction fragment length (TRFL) was measured. Questionnaire data were collected on occupation, education, income, smoking, exercise, height and weight. Standard multiple linear regression and multivariate analyses of variance tested for associations between SES and TRFL, adjusting for covariates. A discordant twin analysis was conducted on a subset to verify findings. WBC telomere length was highly variable but significantly shorter in lower SES groups. The mean difference in TRFL between nonmanual and manual SES groups was 163.2 base pairs (bp) of which 22.9 bp (approximately 14%) was accounted for by body mass index, smoking and exercise. Comparison of TRFL in the 17 most discordant SES twin pairs confirmed this difference. Low SES, in addition to the harmful effects of smoking, obesity and lack of exercise, appears to have an impact on telomere length.

  11. Multiple measures of adiposity are associated with mean leukocyte telomere length in the northern Finland birth cohort 1966.

    Directory of Open Access Journals (Sweden)

    Jessica L Buxton

    Full Text Available Studies of leukocyte telomere length (LTL and adiposity have produced conflicting results, and the relationship between body mass index (BMI and telomere length throughout life remains unclear. We therefore tested association of adult LTL measured in 5,598 participants with: i childhood growth measures (BMI and age at adiposity rebound (AR; ii change in BMI from childhood to adulthood and iii adult BMI, waist-to-hip ratio (WHR, body adiposity index (BAI. Childhood BMI at AR was positively associated with LTL at 31 years in women (P = 0.041. Adult BMI and WHR in both men (P = 0.025 and P = 0.049, respectively and women (P = 0.029 and P = 0.008, respectively, and BAI in women (P = 0.021 were inversely associated with LTL at 31 years. An increase in standardised BMI between early childhood and adulthood was associated with shorter adult LTL in women (P = 0.008. We show that LTL is inversely associated with multiple measures of adiposity in both men and women. Additionally, BMI increase in women from childhood to adulthood is associated with shorter telomeres at age 31, potentially indicating accelerated biological ageing.

  12. Effect of reciprocating systems and working lengths on apical microcrack development: a micro-CT Study

    International Nuclear Information System (INIS)

    Oliveira, Bruna Paloma de; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes; Heck, Richard John

    2017-01-01

    The objective of this study was to evaluate the effect of root canal preparation with single-file reciprocating systems at different working lengths on the development of apical microcracks using micro-computed tomographic (micro-CT) imaging. Forty extracted human mandibular incisors were randomly assigned to 4 groups (n=10) according to the systems and working length used to prepare the root canals: Group A - WaveOne Gold at apical foramen (AF), Group B - WaveOne Gold 1 mm short of the AF (AF-1 mm), Group C - Unicone (AF) and Group D - Unicone (AF-1 mm). Micro-CT scanning was performed before and after root canal preparation at an isotropic resolution of 14 μm. Then, three examiners assessed the cross-sectional images generated to detect microcracks in the apical portion of the roots. Apical microcracks were visualized in 3, 1, 1, and 3 specimens in groups A, B, C, and D, respectively. All these microcracks observed after root canal preparation already existed prior to instrumentation, and no new apical microcrack was detected. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal preparation with WaveOne Gold and Unicone, regardless of the working length, was not associated with apical microcrack formation. (author)

  13. Effect of reciprocating systems and working lengths on apical microcrack development: a micro-CT Study

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruna Paloma de; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes, E-mail: bruna_paloma@msn.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Heck, Richard John [Department of Land Resource Science, University of Guelph (Canada)

    2017-11-15

    The objective of this study was to evaluate the effect of root canal preparation with single-file reciprocating systems at different working lengths on the development of apical microcracks using micro-computed tomographic (micro-CT) imaging. Forty extracted human mandibular incisors were randomly assigned to 4 groups (n=10) according to the systems and working length used to prepare the root canals: Group A - WaveOne Gold at apical foramen (AF), Group B - WaveOne Gold 1 mm short of the AF (AF-1 mm), Group C - Unicone (AF) and Group D - Unicone (AF-1 mm). Micro-CT scanning was performed before and after root canal preparation at an isotropic resolution of 14 μm. Then, three examiners assessed the cross-sectional images generated to detect microcracks in the apical portion of the roots. Apical microcracks were visualized in 3, 1, 1, and 3 specimens in groups A, B, C, and D, respectively. All these microcracks observed after root canal preparation already existed prior to instrumentation, and no new apical microcrack was detected. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal preparation with WaveOne Gold and Unicone, regardless of the working length, was not associated with apical microcrack formation. (author)

  14. Bond-Length Distortions in Strained Semiconductor Alloys

    International Nuclear Information System (INIS)

    Woicik, J.C.; Pellegrino, J.G.; Steiner, B.; Miyano, K.E.; Bompadre, S.G.; Sorensen, L.B.; Lee, T.; Khalid, S.

    1997-01-01

    Extended x-ray absorption fine structure measurements performed at In-K edge have resolved the outstanding issue of bond-length strain in semiconductor-alloy heterostructures. We determine the In-As bond length to be 2.581±0.004 Angstrom in a buried, 213 Angstrom thick Ga 0.78 In 0.22 As layer grown coherently on GaAs(001). This bond length corresponds to a strain-induced contraction of 0.015±0.004 Angstrom relative to the In-As bond length in bulk Ga 1-x In x As of the same composition; it is consistent with a simple model which assumes a uniform bond-length distortion in the epilayer despite the inequivalent In-As and Ga-As bond lengths. copyright 1997 The American Physical Society

  15. Neutron detection efficiency determinations for the TUNL neutron-neutron and neutron-proton scattering-length measurements

    International Nuclear Information System (INIS)

    Trotter, D.E. Gonzalez; Meneses, F. Salinas; Tornow, W.; Crowell, A.S.; Howell, C.R.; Schmidt, D.; Walter, R.L.

    2009-01-01

    The methods employed and the results obtained from measurements and calculations of the detection efficiency for the neutron detectors used at Triangle Universities Nuclear Laboratory (TUNL) in the simultaneous determination of the 1 S 0 neutron-neutron and neutron-proton scattering lengths a nn and a np , respectively, are described. Typical values for the detector efficiency were 0.3. Very good agreement between the different experimental methods and between data and calculation has been obtained in the neutron energy range below E n =13MeV.

  16. Measurement of the diffusion length of thermal neutrons inside graphite; Mesure de la longueur de diffusion des neutrons thermiques dans le graphite

    Energy Technology Data Exchange (ETDEWEB)

    Ertaud, A; Beauge, R; Fauquez, H; De Laboulay, H; Mercier, C; Vautrey, L

    1948-11-01

    The diffusion length of thermal neutrons inside a given industrial graphite is determined by measuring the neutron density inside a parallelepipedal piling up of graphite bricks (2.10 x 2.10 x 2.442 m). A 3.8 curies (Ra {alpha} {yields} Be) source is placed inside the parallelepipedal block of graphite and thin manganese detectors are used. Corrections are added to the unweighted measurements to take into account the effects of the damping of supra-thermal neutrons in the measurement area. These corrections are experimentally deduced from the differential measurements made with a cadmium screen interposed between the source and the first plane of measurement. An error analysis completes the report. The diffusion length obtained is: L = 45.7 cm {+-} 0.3. The average density of the graphite used is 1.76 and the average apparent density of the piling up is 1.71. (J.S.)

  17. Thermal significance of fission-track length distributions

    International Nuclear Information System (INIS)

    Crowley, K.D.

    1985-01-01

    The semi-analytical solution of an equation describing the production and shortening of fission tracks in apatite suggests that certain thermal histories have unique length-distribution 'signatures'. Isothermal-heating histories should be characterized by flattened, length-shortened distributions; step-heating histories should be characterized by bimodal track length distributions; and linear-cooling histories should be characterized by negatively skewed, length-shortened distributions. The model formulated here to investigate track length distributions can be used to constrain the thermal histories of natural samples for which unbiased track length data are available - provided that the geologic history of the system of interest can be used to partially constrain one of the unknowns in the model equations, time or temperature. (author)

  18. Length of urethra in the Indian adult male population

    Directory of Open Access Journals (Sweden)

    Venkatesh Krishnamoorthy

    2012-01-01

    Full Text Available Objective: The urethral length has not been measured in the Indian population. Even the international literature in this arena is very sparse. This paper is an attempt to develop a simple anatomical database for urethral length. Materials and Methods: Between January 2010 and April 2011, the urethral lengths of 422 adult male patients who required catheterization as part of regular treatment at our hospital, were recorded after obtaining consent from the patients and from the scientific and ethics review boards of the institution. Patients with history of prostatic or urethral abnormalities were excluded. The balloon of a sterile Foley′s catheter was inflated using 10 cc of saline. The length from the junction of the balloon to the ′Y′ junction of the Foley was measured. The catheter was then passed into the bladder and re-inflated to same volume. The penis was gently straightened and the length of the catheter outside the penis was measured till the premarked point at the ′Y′ junction. Subtracting this from the original length gave the length of the urethra. Results: The mean length of the urethra was 17.55 + 1.42 cm with a range between 14 and 22.5 cm. Conclusions: Literature in which the length of the normal adult male urethra is recorded for a significant sample size is very scarce. Our data adds to basic anatomic information of the male urethra specific to the Indian population. Statistical Methods: Descriptive statistical analysis was performed. The non-linear regression analysis was employed to find the normative values of urethral length according to age class.

  19. Accuracy and reliability of three-dimensional surface reconstruction measurement

    International Nuclear Information System (INIS)

    Mizukami, Chikashi; Yamamoto, Etsuo; Ohmura, Masaki; Oiki, Hiroyuki; Tsuji, Jun; Muneta, Yuki; Tanabe, Makito; Hakuba, Nobuhiro; Azemoto, Syougo.

    1993-01-01

    We are using a new three-dimensional (3-D) surface reconstruction system to measure the temporal bones. This system offers the advantage of observation of the external aperture of the vestibular aqueduct and the porus acusticus internus in living subjects. However, its accuracy has not been confirmed. To investigate the accuracy of this new system, we measured the length of an in situ ceramic ossicular replacement prosthesis (CORP) of known length of 6.0 mm using 3-D surface reconstruction, conventional plain X-ray and polytomography. The CORP was scanned in the axial, sagittal and oblique directions. The mean measured length obtained with the 3-D surface reconstruction images was 5.94±0.21 on vertical scans, 5.91±0.27 on horizontal scans, and 6.01±0.25 on oblique scans. There were no significant differences among the measured lengths obtained in the three directions. Therefore, this 3-D surface reconstruction measurement system is considered to be reliable. Conversely, the mean measured length obtained by plain X-ray was 7.98±0.20, and by polytomography it was 7.94±0.23. These conventional methods have the inherent disadvantage of magnification of size which consequently requires correction. (author)

  20. Effect of temperature and chain length on the viscosity and surface tension of binary systems of N,N-dimethylformamide with 1-octanol, 1-nonanol and 1-decanol

    International Nuclear Information System (INIS)

    Mohammad, Abubaker A.; Alkhaldi, Khaled H.A.E.; AlTuwaim, Mohammad S.; Al-Jimaz, Adel S.

    2014-01-01

    Highlights: • Effect of temperature and chain length on η and σ of DMF + 1-alkanol binary systems. • Viscosity and surface tension were obtained. • Δη, Δσ and G ∗E were calculated using the experimental data. • H σ and S σ were determined using the surface tension data. • Semi-empirical relations were used to estimate the viscosity of liquid mixtures. - Abstract: Viscosity and surface tension of binary systems of N,N-dimethylformamide DMF with higher 1-alkanols (C 8 –C 10 ) were measured at atmospheric pressure and four different temperatures over the entire range of mole fraction. The experimental measurements were used to calculate the deviations in viscosity and surface tension. Furthermore, the excess Gibbs free energy of activation, surface enthalpy and surface entropy of the (DMF + 1-alkanols) binary mixtures were determined. In addition, the deviation and excess properties were fitted to the method of Redlich–Kister (R–K) polynomial. Viscosity data of the binary systems were correlated with three different expressions (Grunberg and Nissan, the three-body, and four-body McAllister). The effects of the chain length of the higher 1-alkanols and temperature were investigated

  1. Ultrasonographic assessment of renal length in 310 Turkish children ...

    African Journals Online (AJOL)

    Scanning was performed with a 3.5 MHz ultrasound probe in the supine position. The ultrasonographic appearance of the kidneys we measured was normal. The maximum length of each kidney was measured. The renal length was correlated with somatic parameters including age, body height and weight. Regression ...

  2. Length expectation values in quantum Regge calculus

    International Nuclear Information System (INIS)

    Khatsymovsky, V.M.

    2004-01-01

    Regge calculus configuration superspace can be embedded into a more general superspace where the length of any edge is defined ambiguously depending on the 4-tetrahedron containing the edge. Moreover, the latter superspace can be extended further so that even edge lengths in each the 4-tetrahedron are not defined, only area tensors of the 2-faces in it are. We make use of our previous result concerning quantization of the area tensor Regge calculus which gives finite expectation values for areas. Also our result is used showing that quantum measure in the Regge calculus can be uniquely fixed once we know quantum measure on (the space of the functionals on) the superspace of the theory with ambiguously defined edge lengths. We find that in this framework quantization of the usual Regge calculus is defined up to a parameter. The theory may possess nonzero (of the order of Planck scale) or zero length expectation values depending on whether this parameter is larger or smaller than a certain value. Vanishing length expectation values means that the theory is becoming continuous, here dynamically in the originally discrete framework

  3. A methodology for direct quantification of over-ranging length in helical computed tomography with real-time dosimetry.

    Science.gov (United States)

    Tien, Christopher J; Winslow, James F; Hintenlang, David E

    2011-01-31

    In helical computed tomography (CT), reconstruction information from volumes adjacent to the clinical volume of interest (VOI) is required for proper reconstruction. Previous studies have relied upon either operator console readings or indirect extrapolation of measurements in order to determine the over-ranging length of a scan. This paper presents a methodology for the direct quantification of over-ranging dose contributions using real-time dosimetry. A Siemens SOMATOM Sensation 16 multislice helical CT scanner is used with a novel real-time "point" fiber-optic dosimeter system with 10 ms temporal resolution to measure over-ranging length, which is also expressed in dose-length-product (DLP). Film was used to benchmark the exact length of over-ranging. Over-ranging length varied from 4.38 cm at pitch of 0.5 to 6.72 cm at a pitch of 1.5, which corresponds to DLP of 131 to 202 mGy-cm. The dose-extrapolation method of Van der Molen et al. yielded results within 3%, while the console reading method of Tzedakis et al. yielded consistently larger over-ranging lengths. From film measurements, it was determined that Tzedakis et al. overestimated over-ranging lengths by one-half of beam collimation width. Over-ranging length measured as a function of reconstruction slice thicknesses produced two linear regions similar to previous publications. Over-ranging is quantified with both absolute length and DLP, which contributes about 60 mGy-cm or about 10% of DLP for a routine abdominal scan. This paper presents a direct physical measurement of over-ranging length within 10% of previous methodologies. Current uncertainties are less than 1%, in comparison with 5% in other methodologies. Clinical implantation can be increased by using only one dosimeter if codependence with console readings is acceptable, with an uncertainty of 1.1% This methodology will be applied to different vendors, models, and postprocessing methods--which have been shown to produce over-ranging lengths

  4. A novel method for length of chirped fiber Bragg grating sensor

    Science.gov (United States)

    Li, Zhenwei; Wei, Peng; Liu, Taolin

    2018-03-01

    Length of chirped fiber Bragg grating sensor is very important for detonation velocity. Different from other ways, we proposed a novel method based on the optical frequency domain reflection theory to measure the length of chirped fiber grating sensor in non-contact condition. This method adopts a tunable laser source to provide wavelength scanning laser, which covers the Full Width at Half Maximum of spectrum of the chirped fiber Bragg grating sensor. A Michelson interferometer is used to produce optical interference signal. Finally, the grating's length is attainable by distance domain signal. In theory, length resolution of chirped fiber Bragg grating sensor could be 0.02 mm. We perform a series of length measurement experiments for chirped fiber grating sensor, including comparison experiments with hot-tip method. And the experiment results show that the novel method could accurately measure the length of chirped fiber Bragg grating sensors, and the length differences between the optical frequency domain reflection method and the hot-tip probe method are very small.

  5. Experimental research on laser tracking system with galvanometer scanner for measuring spatial coordinates of moving target

    Science.gov (United States)

    Wang, Jia; Hu, Zhaohui; Liu, Yongdong; Liang, Jinwen

    2000-10-01

    The spatial position of industrial object, such as robot end- effector, is an important geometric parameter whose accuracy determines whether robot can perform accurately. Therefore, we have established a laser tracking and coordinate measuring system with galvanometer scanner for high accuracy, large range, non- contact, and spatial dynamic measurement. In this paper, the laser tracking system and its setup are illuminated at first. Then, the formulae for calculating coordinates are deduced, and the calibration method of the initial distance from tracking mirror to target is presented. After that, two preliminary experiments in different distances are described. One is on CMM; the other is with grating ruler as reference. In the former, the maximum measurement error of coordinates is 70micrometers and the maximum error of length is 35micrometers in the 85x100x100mm3 measurement volume, and in the 1m initial distance. In the later, the maximum error of length is 140micrometers in the range of 480mm, and in the 5m initial distance. At the end of the paper, the error sources are analyzed and simulated.

  6. Neutron detection efficiency determinations for the TUNL neutron-neutron and neutron-proton scattering-length measurements

    Energy Technology Data Exchange (ETDEWEB)

    Trotter, D.E. Gonzalez [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States)], E-mail: crowell@tunl.duke.edu; Meneses, F. Salinas [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Tornow, W. [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States)], E-mail: tornow@tunl.duke.edu; Crowell, A.S.; Howell, C.R. [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Schmidt, D. [Physikalisch-Technische Bundesanstalt, D-38116, Braunschweig (Germany); Walter, R.L. [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States)

    2009-02-11

    The methods employed and the results obtained from measurements and calculations of the detection efficiency for the neutron detectors used at Triangle Universities Nuclear Laboratory (TUNL) in the simultaneous determination of the {sup 1}S{sub 0} neutron-neutron and neutron-proton scattering lengths a{sub nn} and a{sub np}, respectively, are described. Typical values for the detector efficiency were 0.3. Very good agreement between the different experimental methods and between data and calculation has been obtained in the neutron energy range below E{sub n}=13MeV.

  7. Time-dependent evolution of strand transfer length in pretensioned prestressed concrete members

    Science.gov (United States)

    Caro, L. A.; Martí-Vargas, J. R.; Serna, P.

    2013-11-01

    For design purposes, it is generally considered that prestressing strand transfer length does not change with time. However, some experimental studies on the effect of time on transfer lengths show contradictory results. In this paper, an experimental research to study transfer length changes over time is presented. A test procedure based on the ECADA testing technique to measure prestressing strand force variation over time in pretensioned prestressed concrete specimens has been set up. With this test method, an experimental program that varies concrete strength, specimen cross section, age of release, prestress transfer method, and embedment length has been carried out. Both the initial and long-term transfer lengths of 13-mm prestressing steel strands have been measured. The test results show that transfer length variation exists for some prestressing load conditions, resulting in increased transfer length over time. The applied test method based on prestressing strand force measurements has shown more reliable results than procedures based on measuring free end slips and longitudinal strains of concrete. An additional factor for transfer length models is proposed in order to include the time-dependent evolution of strand transfer length in pretensioned prestressed concrete members.

  8. Phase behaviour of an ionic microemulsion system as a function of the cosurfactant chain length

    NARCIS (Netherlands)

    Kegel, W.K.; Lekkerkerker, H.N.W.

    1993-01-01

    The phase behaviour of a microemulsion system consisting of equal volumes of brine and oil, sodium dodecyl sulphate (SDS) as surfactant and alcohols of different chain lengths (pentanol, hexanol and heptanol) as cosurfactant was studied. In the case of pentanol, at low surfactant concentrations and

  9. Do illness rating systems predict discharge location, length of stay, and cost after total hip arthroplasty?

    Directory of Open Access Journals (Sweden)

    Sarah E. Rudasill, BA

    2018-06-01

    Conclusions: These findings suggest that although ASA classifications predict discharge location and SOI scores predict length of stay and total costs, other factors beyond illness rating systems remain stronger predictors of discharge for THA patients.

  10. Economic issues of broiler production length

    Directory of Open Access Journals (Sweden)

    Szőllősi László

    2014-01-01

    Full Text Available The length of broiler production cycle is also an important factor when profitability is measured. This paper is to determine the effects of different market ages and down-time period, overall broiler production cycle length on performance and economic parameters based on Hungarian production and financial circumstances. A deterministic model was constructed to manage the function-like correlations of age-related daily weight gain, daily feed intake and daily mortality data. The results show that broiler production cycle length has a significant effect on production and economic performance. Cycle length is determined by the length of down-time and grow-out periods. If down-time period is reduced by one day, an average net income of EUR 0.55 per m2 is realizable. However, the production period is not directly proportional either with emerging costs or obtainable revenues. Profit maximization is attainable if the production period is 41-42 days.

  11. Sorghum cobalt analysis on not determined wave length with atomic ...

    African Journals Online (AJOL)

    This study was to know the better wave length on measuring cobalt content in forage sorghum hybrid (Sorghum bicolor) with an atomic absorption spectrophotometer. The analysis was on background correction mode with three wave lengths; 240.8, 240.7 (determined wave length or recommended wave length) and 240.6 ...

  12. The Modernization of a Long-Focal Length Fringe-Type Laser Velocimeter

    Science.gov (United States)

    Meyers, James F.; Lee, Joseph W.; Cavone, Angelo A.; Fletcher, Mark T.

    2012-01-01

    A long-focal length laser velocimeter constructed in the early 1980's was upgraded using current technology to improve usability, reliability and future serviceability. The original, free-space optics were replaced with a state-of-the-art fiber-optic subsystem which allowed most of the optics, including the laser, to be remote from the harsh tunnel environment. General purpose high-speed digitizers were incorporated in a standard modular data acquisition system, along with custom signal processing software executed on a desktop computer, served as the replacement for the signal processors. The resulting system increased optical sensitivity with real-time signal/data processing that produced measurement precisions exceeding those of the original system. Monte Carlo simulations, along with laboratory and wind tunnel investigations were used to determine system characteristics and measurement precision.

  13. Wildfire fuel harvesting and resultant biomass utilization using a cut-to-length/small chipper system

    Science.gov (United States)

    M. Chad Bolding; Bobby L. Lanford

    2005-01-01

    Currently, there is a lack of information concerning mechanical forest fuel reduction. This study examined and measured the feasibility of ground-based mechanical harvesting to reduce forest fuel buildup and produce energywood. Cut-to-length (CTL) harvesting coupled with a small in-woods chipper provided a low impact way to harvest pre-commercial trees and tops along...

  14. What is the real value of diffusion length in GaN?

    International Nuclear Information System (INIS)

    Yakimov, E.B.

    2015-01-01

    Highlights: • The applicability of SEM methods for diffusion length measurements in GaN is discussed. • The discussion is based on our own experiments and on the available literature data. • A study of EBIC dependence on beam energy suits well for a small diffusion length. • The most reliable diffusion length values in the state-of-the-art n-GaN are evaluated. - Abstract: The applicability of scanning electron microscopy methods for excess carrier diffusion length measurements in GaN is discussed. The discussion is based on author’s experiments and on the available literature data. It is shown that for semiconductors with submicron diffusion length special attention should be paid to the choice of measuring method and experimental conditions. Some reasons for diffusion length overestimation and underestimation are analyzed. It is shown that a measurement of collected current dependence on electron beam energy is the most suitable method for submicron diffusion length evaluations because it is much easier to meet conditions for a proper application of this method than for other widely used methods. The analysis of data previously reported in literature and author’s results have shown that the diffusion length values in the range from 70 to 400 nm are the most reliable for state-of-the-art n-GaN epilayers

  15. Measurement of diffusion length of thermal neutrons in concrete

    International Nuclear Information System (INIS)

    Moser, M.

    2007-04-01

    The diffusion length of neutrons with a medium energy < 0.025 eV in concrete were determined using 4π-β detector and gamma detectors. Then it was possible to determine how deep can neutrons penetrate diverse concrete construction parts in a reactor in operation, with this method the dismantling process of a reactor can be planned in terms of what parts can be removed without danger and what parts can be assumed still are activated. (nevyjel)

  16. A system to measure the kinematics during the entire ski jump sequence using inertial sensors.

    Science.gov (United States)

    Chardonnens, Julien; Favre, Julien; Cuendet, Florian; Gremion, Gérald; Aminian, Kamiar

    2013-01-04

    Three-dimensional analysis of the entire sequence in ski jumping is recommended when studying the kinematics or evaluating performance. Camera-based systems which allow three-dimensional kinematics measurement are complex to set-up and require extensive post-processing, usually limiting ski jumping analyses to small numbers of jumps. In this study, a simple method using a wearable inertial sensors-based system is described to measure the orientation of the lower-body segments (sacrum, thighs, shanks) and skis during the entire jump sequence. This new method combines the fusion of inertial signals and biomechanical constraints of ski jumping. Its performance was evaluated in terms of validity and sensitivity to different performances based on 22 athletes monitored during daily training. The validity of the method was assessed by comparing the inclination of the ski and the slope at landing point and reported an error of -0.2±4.8°. The validity was also assessed by comparison of characteristic angles obtained with the proposed system and reference values in the literature; the differences were smaller than 6° for 75% of the angles and smaller than 15° for 90% of the angles. The sensitivity to different performances was evaluated by comparing the angles between two groups of athletes with different jump lengths and by assessing the association between angles and jump lengths. The differences of technique observed between athletes and the associations with jumps length agreed with the literature. In conclusion, these results suggest that this system is a promising tool for a generalization of three-dimensional kinematics analysis in ski jumping. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. VLSI Design of a Variable-Length FFT/IFFT Processor for OFDM-Based Communication Systems

    Directory of Open Access Journals (Sweden)

    Jen-Chih Kuo

    2003-12-01

    Full Text Available The technique of {orthogonal frequency division multiplexing (OFDM} is famous for its robustness against frequency-selective fading channel. This technique has been widely used in many wired and wireless communication systems. In general, the {fast Fourier transform (FFT} and {inverse FFT (IFFT} operations are used as the modulation/demodulation kernel in the OFDM systems, and the sizes of FFT/IFFT operations are varied in different applications of OFDM systems. In this paper, we design and implement a variable-length prototype FFT/IFFT processor to cover different specifications of OFDM applications. The cached-memory FFT architecture is our suggested VLSI system architecture to design the prototype FFT/IFFT processor for the consideration of low-power consumption. We also implement the twiddle factor butterfly {processing element (PE} based on the {{coordinate} rotation digital computer (CORDIC} algorithm, which avoids the use of conventional multiplication-and-accumulation unit, but evaluates the trigonometric functions using only add-and-shift operations. Finally, we implement a variable-length prototype FFT/IFFT processor with TSMC 0.35 μm 1P4M CMOS technology. The simulations results show that the chip can perform (64-2048-point FFT/IFFT operations up to 80 MHz operating frequency which can meet the speed requirement of most OFDM standards such as WLAN, ADSL, VDSL (256∼2K, DAB, and 2K-mode DVB.

  18. A STUDY OF CORRELATION OF FOOT LENGTH AND GESTATIONAL MATURITY IN NEONATES

    Directory of Open Access Journals (Sweden)

    M. Bhuvaneswari

    2018-03-01

    Full Text Available BACKGROUND Gestational age estimation at birth can be done by clinical estimation through careful history of LMP, ultrasonic estimation of gestational age, date of first recorded foetal activity “quickening” first felt at approximately 16-18 weeks, Date of first recorded foetal heart sounds. MATERIALS AND METHODS A study sample of 800 live newborns were selected by simple random sampling technique born at GVR hospital and Government General Hospital, Kurnool from April 2015 to May 2016. Data was collected using standard proforma meeting the objectives of the study. a Gestational age assessment was done using modified Bellard’s score and b Foot length was measured using sliding calipers which is having an accuracy of a millimeter. Following instruments are used: 1 Sliding calipers for measuring foot length, 2 Flexible, non-stretchable measuring tape for head circumference, 3 Infantometer for measuring crown heel length, 4 Electronic weighing scale for measuring weight. RESULTS The foot length of preterm neonates ranged from 4.5-7.8 cm with the mean foot length of 6.1571 cm and 6.6964 cm for preterm SGA and AGA, respectively. The foot length of term neonates ranged from 5.4-8.7 cm with a mean foot length of 7.0471 cm, 7.5703 cm, 8.0391 cm for term SGA, AGA, LGA respectively. The foot length for post term neonates ranged from 6.7-8.8 cm, with a mean foot length of 7.5688 cm, 8.0170 cm and 8.2667 cm for post term SGA, AGA and LGA, respectively. This shows that foot length increases as the gestational age increases. CONCLUSION Foot length can be correlated significantly with the gestational age, birth weight, head circumference and crown heel length.

  19. Length scale hierarchy and spatiotemporal change of alluvial morphologies over the Selenga River delta, Russia

    Science.gov (United States)

    Dong, T. Y.; Nittrouer, J.; McElroy, B. J.; Ma, H.; Czapiga, M. J.; Il'icheva, E.; Pavlov, M.; Parker, G.

    2017-12-01

    The movement of water and sediment in natural channels creates various types of alluvial morphologies that span length scales from dunes to deltas. The behavior of these morphologies is controlled microscopically by hydrodynamic conditions and bed material size, and macroscopically by hydrologic and geological settings. Alluvial morphologies can be modeled as either diffusive or kinematic waves, in accordance with their respective boundary conditions. Recently, it has been shown that the difference between these two dynamic behaviors of alluvial morphologies can be characterized by the backwater number, which is a dimensionless value normalizing the length scale of a morphological feature to its local hydrodynamic condition. Application of the backwater number has proven useful for evaluating the size of morphologies, including deltas (e.g., by assessing the preferential avulsion location of a lobe), and for comparing bedform types across different fluvial systems. Yet two critical questions emerge when applying the backwater number: First, how do different types of alluvial morphologies compare within a single deltaic system, where there is a hydrodynamic transition from uniform to non-uniform flow? Second, how do different types of morphologies evolve temporally within a system as a function of changing water discharge? This study addresses these questions by compiling and analyzing field data from the Selenga River delta, Russia, which include measurements of flow velocity, channel geometry, bed material grain size, and channel slope, as well as length scales of various morphologies, including dunes, island bars, meanders, bifurcations, and delta lobes. Data analyses reveal that the length scale of morphologies decrease and the backwater number increases as flow transitions from uniform to non-uniform conditions progressing downstream. It is shown that the evaluated length scale hierarchy and planform distribution of different morphologies can be used to

  20. Compact all-fiber interferometer system for shock acceleration measurement

    Science.gov (United States)

    Zhao, Jiang; Pi, Shaohua; Hong, Guangwei; Zhao, Dong; Jia, Bo

    2013-08-01

    Acceleration measurement plays an important role in a variety of fields in science and engineering. In particular, the accurate, continuous and non-contact recording of the shock acceleration profiles of the free target surfaces is considered as a critical technique in shock physics. Various kinds of optical interferometers have been developed to monitor the motion of the surfaces of shocked targets since the 1960s, for instance, the velocity interferometer system for any reflector, the fiber optic accelerometer, the photonic Doppler velocimetry system and the displacement interferometer. However, most of such systems rely on the coherent quasi-monochromatic illumination and discrete optic elements, which are costly in setting-up and maintenance. In 1996, L. Levin et al reported an interferometric fiber-optic Doppler velocimeter with high-dynamic range, in which fiber-coupled components were used to replace the discrete optic elements. However, the fringe visibility of the Levin's system is low because of the coupled components, which greatly limits the reliability and accuracy in the shock measurement. In this paper, a compact all-fiber interferometer system for measuring the shock acceleration is developed and tested. The advantage of the system is that not only removes the non-interfering light and enhances the fringe visibility, but also reduces polarization induced signal fading and the polarization induced phase shift. Moreover, it also does not require a source of long coherence length. The system bases entirely on single-mode fiber optics and mainly consists of a polarization beam splitter, a faraday rotator, a depolarizer and a 3×3 single-mode fiber coupler which work at 1310 nm wavelength. The optical systems of the interferometer are described and the experimental results compared with a shock acceleration calibration system with a pneumatic exciter (PneuShockTM Model 9525C by The Modal Shop) are reported. In the shock acceleration test, the

  1. Electron heating caused by the ion-acoustic decay instability in a finite-length system

    International Nuclear Information System (INIS)

    Rambo, P.W.; Woo, W.; DeGroot, J.S.; Mizuno, K.

    1984-01-01

    The ion-acoustic decay instability is investigated for a finite-length plasma with density somewhat below the cutoff density of the electromagnetic driver (napprox.0.7n/sub c/). For this regime, the heating in a very long system can overpopulate the electron tail and cause linear saturation of the low phase velocity electron plasma waves. For a short system, the instability is nonlinearly saturated at larger amplitude by ion trapping. Absorption can be significantly increased by the large-amplitude ion waves. These results compare favorably with microwave experiments

  2. Apple fruit diameter and length estimation by using the thermal and sunshine hours approach and its application to the digital orchard management information system.

    Science.gov (United States)

    Li, Ming; Chen, Meixiang; Zhang, Yong; Fu, Chunxia; Xing, Bin; Li, Wenyong; Qian, Jianping; Li, Sha; Wang, Hui; Fan, Xiaodan; Yan, Yujing; Wang, Yan'an; Yang, Xinting

    2015-01-01

    In apple cultivation, simulation models may be used to monitor fruit size during the growth and development process to predict production levels and to optimize fruit quality. Here, Fuji apples cultivated in spindle-type systems were used as the model crop. Apple size was measured during the growing period at an interval of about 20 days after full bloom, with three weather stations being used to collect orchard temperature and solar radiation data at different sites. Furthermore, a 2-year dataset (2011 and 2012) of apple fruit size measurements were integrated according to the weather station deployment sites, in addition to the top two most important environment factors, thermal and sunshine hours, into the model. The apple fruit diameter and length were simulated using physiological development time (PDT), an indicator that combines important environment factors, such as temperature and photoperiod, as the driving variable. Compared to the model of calendar-based development time (CDT), an indicator counting the days that elapse after full bloom, we confirmed that the PDT model improved the estimation accuracy to within 0.2 cm for fruit diameter and 0.1 cm for fruit length in independent years using a similar data collection method in 2013. The PDT model was implemented to realize a web-based management information system for a digital orchard, and the digital system had been applied in Shandong Province, China since 2013. This system may be used to compute the dynamic curve of apple fruit size based on data obtained from a nearby weather station. This system may provide an important decision support for farmers using the website and short message service to optimize crop production and, hence, economic benefit.

  3. Pressure measurements in the AGS Booster ultra-high vacuum system

    International Nuclear Information System (INIS)

    Gabusi, J.; Geller, J.; Hseuh, H.C.; Mapes, M.; Stattel, P.

    1992-01-01

    An average pressure of mid 10 -11 Torr has been achieved and maintained in the AGS Booster ring vacuum system during its first year of operation. This ultra-high vacuum system is monitored through remote controlled Bayard-Alpert Gauges (BAGs). The characteristics of the pressure measurements with BAGs over the long cable lengths (up to 200 m) and under various accelerator operating conditions will be described. Two types of noise in the pressure readouts have been identified; the electromagnetic interference (EMI) associated with the acceleration cycles of the Booster and the environment noise associated with the temperature of the collector cables. The magnitude of the noise pickup depends on the routing of the collector cables and reaches the equivalent pressure of low 10 -9 Torr

  4. Beam derived trigger system for multibunch time-of-flight measurement

    International Nuclear Information System (INIS)

    Fox, J.; Pellegrin, J.L.

    1981-01-01

    Particle time-of-flight measurement requires accurate triggers in synchronism with each bunch, and occurring in a sequence which depends on the position of the observer around the storage ring. A system has been devised for tagging the colliding bunches at each interaction point; it allows one to record which pair of bunches is colliding at any time and any location around the machine. Besides bunch identification, the time-of-flight triggers are also expected to have a time stability better than the bunch length itself. A system is presented here which exhibits time variations of less than 80 psec over a 20 to 1 range of beam current, while the jitter is at least an order of magnitude smaller. 4 refs., 4 figs

  5. Diffusion as a Ruler: Modeling Kinesin Diffusion as a Length Sensor for Intraflagellar Transport.

    Science.gov (United States)

    Hendel, Nathan L; Thomson, Matthew; Marshall, Wallace F

    2018-02-06

    An important question in cell biology is whether cells are able to measure size, either whole cell size or organelle size. Perhaps cells have an internal chemical representation of size that can be used to precisely regulate growth, or perhaps size is just an accident that emerges due to constraint of nutrients. The eukaryotic flagellum is an ideal model for studying size sensing and control because its linear geometry makes it essentially one-dimensional, greatly simplifying mathematical modeling. The assembly of flagella is regulated by intraflagellar transport (IFT), in which kinesin motors carry cargo adaptors for flagellar proteins along the flagellum and then deposit them at the tip, lengthening the flagellum. The rate at which IFT motors are recruited to begin transport into the flagellum is anticorrelated with the flagellar length, implying some kind of communication between the base and the tip and possibly indicating that cells contain some mechanism for measuring flagellar length. Although it is possible to imagine many complex scenarios in which additional signaling molecules sense length and carry feedback signals to the cell body to control IFT, might the already-known components of the IFT system be sufficient to allow length dependence of IFT? Here we investigate a model in which the anterograde kinesin motors unbind after cargo delivery, diffuse back to the base, and are subsequently reused to power entry of new IFT trains into the flagellum. By mathematically modeling and simulating such a system, we are able to show that the diffusion time of the motors can in principle be sufficient to serve as a proxy for length measurement. We found that the diffusion model can not only achieve a stable steady-state length without the addition of any other signaling molecules or pathways, but also is able to produce the anticorrelation between length and IFT recruitment rate that has been observed in quantitative imaging studies. Copyright © 2017 Biophysical

  6. A Decision Support System to Choose Optimal Release Cycle Length in Incremental Software Development Environments

    OpenAIRE

    Suman, Avnish Chandra; Mishra, Saraswati; Anand, Abhinav

    2016-01-01

    In the last few years it has been seen that many software vendors have started delivering projects incrementally with very short release cycles. Best examples of success of this approach has been Ubuntu Operating system that has a 6 months release cycle and popular web browsers such as Google Chrome, Opera, Mozilla Firefox. However there is very little knowledge available to the project managers to validate the chosen release cycle length. We propose a decision support system that...

  7. Influence of exposure to pesticides on telomere length in tobacco farmers: A biology system approach.

    Science.gov (United States)

    Kahl, Vivian Francília Silva; da Silva, Juliana; da Silva, Fernanda Rabaioli

    Various pesticides in the form of mixtures must be used to keep tobacco crops pest-free. Recent studies have shown a link between occupational exposure to pesticides in tobacco crops and increased damage to the DNA, mononuclei, nuclear buds and binucleated cells in buccal cells as well as micronuclei in lymphocytes. Furthermore, pesticides used specifically for tobacco crops shorten telomere length (TL) significantly. However, the molecular mechanism of pesticide action on telomere length is not fully understood. Our study evaluated the interaction between a complex mixture of chemical compounds (tobacco cultivation pesticides plus nicotine) and proteins associated with maintaining TL, as well as the biological processes involved in this exposure by System Biology tools to provide insight regarding the influence of pesticide exposure on TL maintenance in tobacco farmers. Our analysis showed that one cluster was associated with TL proteins that act in bioprocesses such as (i) telomere maintenance via telomere lengthening; (ii) senescence; (iii) age-dependent telomere shortening; (iv) DNA repair (v) cellular response to stress and (vi) regulation of proteasome ubiquitin-dependent protein catabolic process. We also describe how pesticides and nicotine regulate telomere length. In addition, pesticides inhibit the ubiquitin proteasome system (UPS) and consequently increase proteins of the shelterin complex, avoiding the access of telomerase in telomere and, nicotine activates UPS mechanisms and promotes the degradation of human telomerase reverse transcriptase (hTERT), decreasing telomerase activity. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. An Experimental Measurement on Laminar Burning Velocities and Markstein Length of Iso-Butane-Air Mixtures at Ambient Conditions

    Directory of Open Access Journals (Sweden)

    Yousif Alaeldeen Altag

    2016-01-01

    Full Text Available In the present work, experimental investigation on laminar combustion of iso-butane-air mixtures was conducted in constant volume explosion vessel. The experiments were conducted at wide range of equivalence ratios ranging between Ф = 0.6 and 1.4 and atmospheric pressure of 0.1 MPa and ambient temperature of 303K. Using spherically expanding flame method, flame parameters including stretched, unstretched flame propagation speeds, laminar burning velocities and Markstein length were calculated. For laminar burning velocities the method of error bars of 95% confidence level was applied. In addition, values of Markstein lengths were measured in wide range of equivalence ratios to study the influence of stretch rate on flame instability and burning velocity. It was found that the stretched flame speed and laminar burning velocities increased with equivalence ratios and the peak value was obtained at equivalence ratio of Ф = 1.1. The Markstein length decreased with the increases in equivalence ratios, which indicates that the diffusion thermal flame instability increased at high equivalence ratios in richer mixture side. However, the total deviations in the laminar burning velocities have discrepancies of 1.2-2.9% for all investigated mixtures.

  9. Topological analysis of polymeric melts: chain-length effects and fast-converging estimators for entanglement length.

    Science.gov (United States)

    Hoy, Robert S; Foteinopoulou, Katerina; Kröger, Martin

    2009-09-01

    Primitive path analyses of entanglements are performed over a wide range of chain lengths for both bead spring and atomistic polyethylene polymer melts. Estimators for the entanglement length N_{e} which operate on results for a single chain length N are shown to produce systematic O(1/N) errors. The mathematical roots of these errors are identified as (a) treating chain ends as entanglements and (b) neglecting non-Gaussian corrections to chain and primitive path dimensions. The prefactors for the O(1/N) errors may be large; in general their magnitude depends both on the polymer model and the method used to obtain primitive paths. We propose, derive, and test new estimators which eliminate these systematic errors using information obtainable from the variation in entanglement characteristics with chain length. The new estimators produce accurate results for N_{e} from marginally entangled systems. Formulas based on direct enumeration of entanglements appear to converge faster and are simpler to apply.

  10. Health inequalities in Ethiopia: modeling inequalities in length of life within and between population groups.

    Science.gov (United States)

    Tranvåg, Eirik Joakim; Ali, Merima; Norheim, Ole Frithjof

    2013-07-11

    Most studies on health inequalities use average measures, but describing the distribution of health can also provide valuable knowledge. In this paper, we estimate and compare within-group and between-group inequalities in length of life for population groups in Ethiopia in 2000 and 2011. We used data from the 2011 and 2000 Ethiopia Demographic and Health Survey and the Global Burden of Disease study 2010, and the MODMATCH modified logit life table system developed by the World Health Organization to model mortality rates, life expectancy, and length of life for Ethiopian population groups stratified by wealth quintiles, gender and residence. We then estimated and compared within-group and between-group inequality in length of life using the Gini index and absolute length of life inequality. Length of life inequality has decreased and life expectancy has increased for all population groups between 2000 and 2011. Length of life inequality within wealth quintiles is about three times larger than the between-group inequality of 9 years. Total length of life inequality in Ethiopia was 27.6 years in 2011. Longevity has increased and the distribution of health in Ethiopia is more equal in 2011 than 2000, with length of life inequality reduced for all population groups. Still there is considerable potential for further improvement. In the Ethiopian context with a poor and highly rural population, inequality in length of life within wealth quintiles is considerably larger than between them. This suggests that other factors than wealth substantially contribute to total health inequality in Ethiopia and that identification and quantification of these factors will be important for identifying proper measures to further reduce length of life inequality.

  11. Overview of the Spinal Cord Injury--Quality of Life (SCI-QOL) measurement system.

    Science.gov (United States)

    Tulsky, David S; Kisala, Pamela A; Victorson, David; Tate, Denise G; Heinemann, Allen W; Charlifue, Susan; Kirshblum, Steve C; Fyffe, Denise; Gershon, Richard; Spungen, Ann M; Bombardier, Charles H; Dyson-Hudson, Trevor A; Amtmann, Dagmar; Kalpakjian, Claire Z; Choi, Seung W; Jette, Alan M; Forchheimer, Martin; Cella, David

    2015-05-01

    The Spinal Cord Injury--Quality of Life (SCI-QOL) measurement system was developed to address the shortage of relevant and psychometrically sound patient reported outcome (PRO) measures available for clinical care and research in spinal cord injury (SCI) rehabilitation. Using a computer adaptive testing (CAT) approach, the SCI-QOL builds on the Patient Reported Outcomes Measurement Information System (PROMIS) and the Quality of Life in Neurological Disorders (Neuro-QOL) initiative. This initial manuscript introduces the background and development of the SCI-QOL measurement system. Greater detail is presented in the additional manuscripts of this special issue. Classical and contemporary test development methodologies were employed. Qualitative input was obtained from individuals with SCI and clinicians through interviews, focus groups, and cognitive debriefing. Item pools were field tested in a multi-site sample (n=877) and calibrated using item response theory methods. Initial reliability and validity testing was performed in a new sample of individuals with traumatic SCI (n=245). Five Model SCI System centers and one Department of Veterans Affairs Medical Center across the United States. Adults with traumatic SCI. n/a n/a The SCI-QOL consists of 19 item banks, including the SCI-Functional Index banks, and 3 fixed-length scales measuring physical, emotional, and social aspects of health-related QOL (HRQOL). The SCI-QOL measurement system consists of psychometrically sound measures for individuals with SCI. The manuscripts in this special issue provide evidence of the reliability and initial validity of this measurement system. The SCI-QOL also links to other measures designed for a general medical population.

  12. Pressure Measurement Systems

    Science.gov (United States)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  13. Determination of the length and position of the lower oesophageal sphincter (LOS) by correlation of external measurements with combined radiographic and manometric estimations in the cat

    International Nuclear Information System (INIS)

    Hashim, M.A.; Waterman, A.E.

    1992-01-01

    Fifty DSH cats were studied radiographically and a highly significant linear correlation was found between the length of the oesophagus measured to the diaphragmatic line on the radiographs and the externally measured distance from the lower jaw incisor teeth to the anterior border of the head of 10th rib. A subsequent manometric study utilizing this correlation in 40 cats suggests that the functional lower oesophageal sphincter (LOS) is situated almost at the level of the diaphragm in the cat. Significant differences were found between the length of the LOS in cats anaesthetized with ketamine compared to alphaxalone-alphadolone or xylazine-ketamine-atropine. The mean lengths of the LOS was 1.42 +/- 0.3 cm. The findings of this study indicate that external measurements can be used to position catheters for accurate oesophageal manometry in the cat

  14. Dynamic Measurement of Extra Long Stroke Cylinder in the Pneumatic System

    International Nuclear Information System (INIS)

    Chang Ho; Lan Chouwei; Chen, L-C

    2006-01-01

    This paper sets up the measure and control system of the dynamic characteristics of the extra long stroke cylinder. In the different types of the control conditions (e.g. different control law, operating pressure and direct control valves), using the measure and control system to measure the relation between the pressure and the velocity of the motion of the long stroke cylinder and to observe the stick slip phenomenon of the motion of the long stroke cylinder. In the innovate measurement system, two pressure sensors are set on the long stroke cylinder to measure the difference of the pressure between the inlet and the exhaust of the long stroke cylinder. In additions, a draw line encoder is set on the system to measure the position and the velocity of the motion of the long stroke cylinder. The measuring data of the measure system is transferred to the computer via A/D interface card and counter card, and Home-made program of Haptic Interface Device is used to control the system, saving the data of the motion of the long stroke cylinder. The system uses different types of direction control valve to control the motion of the long stroke cylinder and compares the difference of the motion of the long stroke cylinder. The results show that the motion of the cylinder that pauses in the middle of the cylinder stroke and causes the stick slip phenomenon is more violent than the stick slip phenomenon in other position. When the length of the pause time reaches the some range, the acceleration of the motion of the cylinder will be rised substantially. This paper not only focuses on the testing method of the dynamic characteristics of the motion of the long stroke cylinder, but also includes the analysis of the dynamic characteristics of the motion of the long stroke cylinder. It provides the data of the dynamic characteristics of the motion of the long stroke cylinder to improve and design the pneumatic system of the long stroke cylinder

  15. Direct comparison of flow-FISH and qPCR as diagnostic tests for telomere length measurement in humans.

    Directory of Open Access Journals (Sweden)

    Fernanda Gutierrez-Rodrigues

    Full Text Available Telomere length measurement is an essential test for the diagnosis of telomeropathies, which are caused by excessive telomere erosion. Commonly used methods are terminal restriction fragment (TRF analysis by Southern blot, fluorescence in situ hybridization coupled with flow cytometry (flow-FISH, and quantitative PCR (qPCR. Although these methods have been used in the clinic, they have not been comprehensively compared. Here, we directly compared the performance of flow-FISH and qPCR to measure leukocytes' telomere length of healthy individuals and patients evaluated for telomeropathies, using TRF as standard. TRF and flow-FISH showed good agreement and correlation in the analysis of healthy subjects (R(2 = 0.60; p<0.0001 and patients (R(2 = 0.51; p<0.0001. In contrast, the comparison between TRF and qPCR yielded modest correlation for the analysis of samples of healthy individuals (R(2 = 0.35; p<0.0001 and low correlation for patients (R(2 = 0.20; p = 0.001; Bland-Altman analysis showed poor agreement between the two methods for both patients and controls. Quantitative PCR and flow-FISH modestly correlated in the analysis of healthy individuals (R(2 = 0.33; p<0.0001 and did not correlate in the comparison of patients' samples (R(2 = 0.1, p = 0.08. Intra-assay coefficient of variation (CV was similar for flow-FISH (10.8 ± 7.1% and qPCR (9.5 ± 7.4%; p = 0.35, but the inter-assay CV was lower for flow-FISH (9.6 ± 7.6% vs. 16 ± 19.5%; p = 0.02. Bland-Altman analysis indicated that flow-FISH was more precise and reproducible than qPCR. Flow-FISH and qPCR were sensitive (both 100% and specific (93% and 89%, respectively to distinguish very short telomeres. However, qPCR sensitivity (40% and specificity (63% to detect telomeres below the tenth percentile were lower compared to flow-FISH (80% sensitivity and 85% specificity. In the clinical setting, flow-FISH was more accurate, reproducible, sensitive, and specific in the measurement of human

  16. Radar orthogonality and radar length in Finsler and metric spacetime geometry

    Science.gov (United States)

    Pfeifer, Christian

    2014-09-01

    The radar experiment connects the geometry of spacetime with an observers measurement of spatial length. We investigate the radar experiment on Finsler spacetimes which leads to a general definition of radar orthogonality and radar length. The directions radar orthogonal to an observer form the spatial equal time surface an observer experiences and the radar length is the physical length the observer associates to spatial objects. We demonstrate these concepts on a forth order polynomial Finsler spacetime geometry which may emerge from area metric or premetric linear electrodynamics or in quantum gravity phenomenology. In an explicit generalization of Minkowski spacetime geometry we derive the deviation from the Euclidean spatial length measure in an observers rest frame explicitly.

  17. Effect of Submergence and Apron Length on Spillway Scour: Case Study

    Directory of Open Access Journals (Sweden)

    Seungho Hong

    2015-10-01

    Full Text Available Large-scale water resources systems are often managed by an integrated set of hydraulic structures that are vulnerable to wider ranges of discharge and tailwater elevation than envisioned in their original design due to climate change and additional project objectives such as fostering healthy ecosystems. The present physical model study explored the performance of a spillway structure on the Kissimmee River, operated by the South Florida Water Management District, under extreme conditions of drought and flooding with accompanying low and high tailwater levels for both gate-controlled and uncontrolled spillway flow conditions. Maximum scour depths and their locations for two different riprap apron lengths downstream of the spillway stilling basin were measured along with the complex flow fields prior to scour. Effects of tailwater submergence, type of spillway flow and riprap apron length on scour results are interpreted in terms of the measured turbulent kinetic energy and velocity distributions near the bed.

  18. Automated egg grading system using computer vision: Investigation on weight measure versus shape parameters

    Science.gov (United States)

    Nasir, Ahmad Fakhri Ab; Suhaila Sabarudin, Siti; Majeed, Anwar P. P. Abdul; Ghani, Ahmad Shahrizan Abdul

    2018-04-01

    Chicken egg is a source of food of high demand by humans. Human operators cannot work perfectly and continuously when conducting egg grading. Instead of an egg grading system using weight measure, an automatic system for egg grading using computer vision (using egg shape parameter) can be used to improve the productivity of egg grading. However, early hypothesis has indicated that more number of egg classes will change when using egg shape parameter compared with using weight measure. This paper presents the comparison of egg classification by the two above-mentioned methods. Firstly, 120 images of chicken eggs of various grades (A–D) produced in Malaysia are captured. Then, the egg images are processed using image pre-processing techniques, such as image cropping, smoothing and segmentation. Thereafter, eight egg shape features, including area, major axis length, minor axis length, volume, diameter and perimeter, are extracted. Lastly, feature selection (information gain ratio) and feature extraction (principal component analysis) are performed using k-nearest neighbour classifier in the classification process. Two methods, namely, supervised learning (using weight measure as graded by egg supplier) and unsupervised learning (using egg shape parameters as graded by ourselves), are conducted to execute the experiment. Clustering results reveal many changes in egg classes after performing shape-based grading. On average, the best recognition results using shape-based grading label is 94.16% while using weight-based label is 44.17%. As conclusion, automated egg grading system using computer vision is better by implementing shape-based features since it uses image meanwhile the weight parameter is more suitable by using weight grading system.

  19. System for automatic gauge block length measurement optimized for secondary length metrology

    Czech Academy of Sciences Publication Activity Database

    Buchta, Zdeněk; Šarbort, Martin; Čížek, Martin; Hucl, Václav; Řeřucha, Šimon; Pikálek, Tomáš; Dvořáčková, Š.; Dvořáček, F.; Kůr, J.; Konečný, P.; Weigl, M.; Lazar, Josef; Číp, Ondřej

    2017-01-01

    Roč. 49, JULY (2017), s. 322-331 ISSN 0141-6359 R&D Projects: GA TA ČR(CZ) TA03010663; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : low-coherence interferometry * laser interferometry * Gauge block * metrology Subject RIV: BH - Optics, Masers, Laser s OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 2.237, year: 2016

  20. The Allometry of Bee Proboscis Length and Its Uses in Ecology.

    Directory of Open Access Journals (Sweden)

    Daniel P Cariveau

    Full Text Available Allometric relationships among morphological traits underlie important patterns in ecology. These relationships are often phylogenetically shared; thus quantifying allometric relationships may allow for estimating difficult-to-measure traits across species. One such trait, proboscis length in bees, is assumed to be important in structuring bee communities and plant-pollinator networks. However, it is difficult to measure and thus rarely included in ecological analyses. We measured intertegular distance (as a measure of body size and proboscis length (glossa and prementum, both individually and combined of 786 individual bees of 100 species across 5 of the 7 extant bee families (Hymenoptera: Apoidea: Anthophila. Using linear models and model selection, we determined which parameters provided the best estimate of proboscis length. We then used coefficients to estimate the relationship between intertegular distance and proboscis length, while also considering family. Using allometric equations with an estimation for a scaling coefficient between intertegular distance and proboscis length and coefficients for each family, we explain 91% of the variance in species-level means for bee proboscis length among bee species. However, within species, individual-level intertegular distance was a poor predictor of individual proboscis length. To make our findings easy to use, we created an R package that allows estimation of proboscis length for individual bee species by inputting only family and intertegular distance. The R package also calculates foraging distance and body mass based on previously published equations. Thus by considering both taxonomy and intertegular distance we enable accurate estimation of an ecologically and evolutionarily important trait.

  1. Reproducibility of Macular Pigment Optical Density Measurement by Two-wave Length Auto-fluorescence in a Clinical Setting

    Science.gov (United States)

    You, Qi-Sheng; Bartsch, Dirk-Uwe G.; Espina, Mark; Alam, Mostafa; Camacho, Natalia; Mendoza, Nadia; Freeman, William

    2015-01-01

    Purpose Macular pigment, composed of lutein, zeaxanthin, and meso-zeaxanthin, is postulated to protect against age-related macular degeneration (AMD), likely due to filtering blue light and its antioxidant properties. Macular pigment optical density (MPOD) is reported to be associated with macular function evaluated by visual acuity and multifocal electroretinogram. Given the importance of macular pigment, reliable and accurate measurement methods are important. The main purpose of current study is to determine the reproducibility of MPOD measurement by two-wave length auto-fluorescence method using scanning laser ophthalmoscopy. Methods Sixty eight eyes of 39 persons were enrolled in the study, including 11 normal eyes, 16 eyes with wet AMD, 16 eyes with dry AMD, 11 eyes with macular edema due to diabetic mellitus, branch retinal vein occlusion or macular telangiectasia and 14 eyes with tractional maculopathy including vitreomacular traction, epiretinal membrane or macular hole. MPOD was measured with a two-wavelength (488 and 514 nm) auto-fluorescence method with the Spectralis HRA+OCT after pupil dilation. The measurement was repeated for each eye 10 minutes later. The Analysis of variance (ANOVA) and Bland-Altman plot were used to assess the reproducibility between the two measurements. Results The mean MPOD at eccentricities of 1° and 2° was 0.36±0.17 (range: 0.04–0.69) and 0.15±0.08(range: −0.03, 0.35) for the first measurement and 0.35±0.17 (range: 0.02, 0.68) and 0.15±0.08 (range: −0.01, 0.33) for the second measurement respectively. The difference between the two measurements was not statistically significant, and the Bland-Altman plot showed 7.4% and 5.9% points outside the 95% limits of agreement, indicating an overall excellent reproducibility. Similarly, there is no significant difference between the first and second measurements of MPOD volume within eccentricities of 1°, 2° and 6° radius, and the Bland-Altman plot showed 8.8%, 2.9% and

  2. DEVELOPMENT AND EVALUATION OF SIMPLE MEASUREMENT SYSTEM USING THE OBLIQUE PHOTO AND DEM

    Directory of Open Access Journals (Sweden)

    H. Nonaka

    2016-06-01

    Full Text Available When a disaster occurs, we must grasp and evaluate its damage as soon as possible. Then we try to estimate them from some kind of photographs, such as surveillance camera imagery, satellite imagery, photographs taken from a helicopter and so on. Especially in initial stage, estimation of decent damage situation for a short time is more important than investigation of damage situation for a long time. One of the source of damage situation is the image taken by surveillance camera, satellite sensor and helicopter. If we can measure any targets in these imagery, we can estimate a length of a lava flow, a reach of a cinder and a sediment volume in volcanic eruption or landslide. Therefore in order to measure various information for a short time, we developed a simplified measurement system which uses these photographs. This system requires DEM in addition to photographs, but it is possible to use previously acquired DEM. To measure an object, we require only two steps. One is the determination of the position and the posture in which the photograph is shot. We determine these parameters using DEM. The other step is the measurement of an object in photograph. In this paper, we describe this system and show the experimental results to evaluate this system. In this experiment we measured the top of Mt. Usu by using two measurement method of this system. Then we can measure it about one hour and the difference between the measurement results and the airborne LiDAR data are less than 10 meter.

  3. A study on assessment of the length of styloid process in digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    Nikita Gupta

    2015-01-01

    Full Text Available Introduction: The styloid process (SP is an anatomical structure whose clinical importance is not well understood. Aims and Objectives: This study aimed to study the type of SP as per Langlais′ classification and to assess the feasibility of digital panoramic radiographs in measuring the length of SP. Materials and Methods: Eighty digital panoramic radiographs of patients with dental problems were retrieved from archives of our department as soft copies. The radiographs were taken using a digital panoramic system. The radiographic length of SP was measured on both sides using measurement toolbars on accompanying analysis software. The type of elongation patterns of SP was classified as per Langlais′ classification. Finally, the data were subjected to statistical analysis. Results: The average length of the left and right side SPs was 29.1882 ± 6.86 and 28.16 ± 6.44, respectively. Majority of patients were found to be asymptomatic, and Langlais′ Type I elongated SP was more common than others. Conclusion: Digital panoramic radiographs are valuable tools in early detection of elongated SP. Digital radiographs help in avoiding a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular region.

  4. Apple fruit diameter and length estimation by using the thermal and sunshine hours approach and its application to the digital orchard management information system.

    Directory of Open Access Journals (Sweden)

    Ming Li

    Full Text Available In apple cultivation, simulation models may be used to monitor fruit size during the growth and development process to predict production levels and to optimize fruit quality. Here, Fuji apples cultivated in spindle-type systems were used as the model crop. Apple size was measured during the growing period at an interval of about 20 days after full bloom, with three weather stations being used to collect orchard temperature and solar radiation data at different sites. Furthermore, a 2-year dataset (2011 and 2012 of apple fruit size measurements were integrated according to the weather station deployment sites, in addition to the top two most important environment factors, thermal and sunshine hours, into the model. The apple fruit diameter and length were simulated using physiological development time (PDT, an indicator that combines important environment factors, such as temperature and photoperiod, as the driving variable. Compared to the model of calendar-based development time (CDT, an indicator counting the days that elapse after full bloom, we confirmed that the PDT model improved the estimation accuracy to within 0.2 cm for fruit diameter and 0.1 cm for fruit length in independent years using a similar data collection method in 2013. The PDT model was implemented to realize a web-based management information system for a digital orchard, and the digital system had been applied in Shandong Province, China since 2013. This system may be used to compute the dynamic curve of apple fruit size based on data obtained from a nearby weather station. This system may provide an important decision support for farmers using the website and short message service to optimize crop production and, hence, economic benefit.

  5. Spontaneous oscillation of tension and sarcomere length in skeletal myofibrils. Microscopic measurement and analysis.

    Science.gov (United States)

    Anazawa, T; Yasuda, K; Ishiwata, S

    1992-05-01

    We have devised a simple method for measuring tension development of single myofibrils by micromanipulation with a pair of glass micro-needles. The tension was estimated from the deflection of a flexible needle under an inverted phase-contrast microscope equipped with an image processor, so that the tension development is always accompanied by the shortening of the myofibril (auxotonic condition) in the present setup. The advantage of this method is that the measurement of tension (1/30 s for time resolution and about 0.05 micrograms for accuracy of tension measurement; 0.05 microns as a spatial resolution for displacement of the micro-needle) and the observation of sarcomere structure are possible at the same time, and the technique to hold myofibrils, even single myofibrils, is very simple. This method has been applied to study the tension development of glycerinated skeletal myofibrils under the condition where spontaneous oscillation of sarcomeres is induced, i.e., the coexistence of MgATP, MgADP and inorganic phosphate without free Ca2+. Under this condition, we found that the tension of myofibrils spontaneously oscillates accompanied by the oscillation of sarcomere length with a main period of a few seconds; the period was lengthened and shortened with stretch and release of myofibrils. A possible mechanism of the oscillation is discussed.

  6. Assessing Telomere Length Using Surface Enhanced Raman Scattering

    Science.gov (United States)

    Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Cui, Yiping

    2014-11-01

    Telomere length can provide valuable insight into telomeres and telomerase related diseases, including cancer. Here, we present a brand-new optical telomere length measurement protocol using surface enhanced Raman scattering (SERS). In this protocol, two single strand DNA are used as SERS probes. They are labeled with two different Raman molecules and can specifically hybridize with telomeres and centromere, respectively. First, genome DNA is extracted from cells. Then the telomere and centromere SERS probes are added into the genome DNA. After hybridization with genome DNA, excess SERS probes are removed by magnetic capturing nanoparticles. Finally, the genome DNA with SERS probes attached is dropped onto a SERS substrate and subjected to SERS measurement. Longer telomeres result in more attached telomere probes, thus a stronger SERS signal. Consequently, SERS signal can be used as an indicator of telomere length. Centromere is used as the inner control. By calibrating the SERS intensity of telomere probe with that of the centromere probe, SERS based telomere measurement is realized. This protocol does not require polymerase chain reaction (PCR) or electrophoresis procedures, which greatly simplifies the detection process. We anticipate that this easy-operation and cost-effective protocol is a fine alternative for the assessment of telomere length.

  7. Radioisotope measurement system

    International Nuclear Information System (INIS)

    Villanueva Ruibal, Jose

    2007-01-01

    A radioisotope measurement system installed at L.M.R. (Ezeiza Atomic Center of CNEA) allows the measurement of nuclear activity from a wide range of radioisotopes. It permits to characterize a broad range of radioisotopes at several activity levels. The measurement hardware as well as the driving software have been developed and constructed at the Dept. of Instrumentation and Control. The work outlines the system's conformation and its operating concept, describes design characteristics, construction and the error treatment, comments assay results and supplies use advices. Measuring tests carried out employing different radionuclides confirmed the system performing satisfactorily and with friendly operation. (author) [es

  8. Magnetic Measurement System for the NSLS Superconducting Undulator Vertical Test Facility

    CERN Document Server

    Harder, David; Skaritka, John

    2005-01-01

    One of the challenges of small-gap superconducting undulators is measurement of magnetic fields within the cold bore to characterize the device performance and to determine magnetic field errors for correction or shimming, as is done for room-temperature undulators. Both detailed field maps and integrated field measurements are required. This paper describes a 6-element, cryogenic Hall probe field mapper for the NSLS Superconducting Undulator Vertical Test Facility (VTF). The probe is designed to work in an aperture only 3 mm high. A pulsed-wire insert is also being developed, for visualization of the trajectory, for locating steering errors and for determining integrated multi-pole errors. The pulsed-wire insert will be interchangeable with the Hall probe mapper. The VTF and the magnetic measurement systems can accommodate undulators up to 0.4 m in length.

  9. Study of optical non-linear properties of a constant total effective length multiple quantum wells system

    International Nuclear Information System (INIS)

    Solaimani, M.; Morteza, Izadifard; Arabshahi, H.; Reza, Sarkardehi Mohammad

    2013-01-01

    In this work, we have studied the effect of the number of the wells, in a multiple quantum wells structure with constant total effective length, on the optical properties of multiple quantum wells like the absorption coefficient and the refractive index by means of compact density matrix approach. GaAs/Al x Ga (1−x) As multiple quantum wells systems was selected as an example. Besides, the effect of varying number of wells on the subband energies, wave functions, number of bound states, and the Fermi energy have been also investigated. Our calculation revealed that the number of wells in a multiple quantum well is a criterion with which we can control the amount of nonlinearity. This study showed that for the third order refractive index change there is two regimes of variations and the critical well number was six. In our calculations, we have used the same wells and barrier thicknesses to construct the multiple quantum wells system. - Highlights: ► OptiOptical Non-Linear. ► Total Effective Length. ► Multiple Quantum Wells System - genetic algorithm ► Schrödinger equation solution. ► Nanostructure.

  10. Laser interferometer system for the measurement of creep in pressurized tubes

    International Nuclear Information System (INIS)

    Kirchner, T.L.

    1976-07-01

    A laser interferometer measurement system was developed to measure the length, diameter, and radius of various pressurized tube specimens. The machine measures and records profilometric data of the pressurized tubes prior to insertion in the reactor and then again after a predetermined fluence has been reached to determine the amount of creep which has occurred. This data provides a statistical basis for the description of steady-state in-reactor creep and creep rupture behavior of the reference fuel cladding and structural materials for the Fast Flux Test Facility (FFTF) and the Clinch River Breeder Reactor (CRBR). In addition, this data will be used to determine the relative in-reactor creep and creep rupture behavior of candidate alloys for advanced cladding and structural materials. The laser interferometer system, referred to as the Biaxial Creep Measurement Machine (BCMM), was built to meet or exceed design criteria such as: automatic measurement of the five biaxial creep specimens varying in size; complete automation of the machine using a mini-computer; complete specimen loading, unloading, and data processing in less than five minutes; storage of data on magnetic cassette tapes; quick-look data readout and error checking during each run to determine proper machine operation; and remote operation in a radioactive environment

  11. Construction of phosphorylation interaction networks by text mining of full-length articles using the eFIP system.

    Science.gov (United States)

    Tudor, Catalina O; Ross, Karen E; Li, Gang; Vijay-Shanker, K; Wu, Cathy H; Arighi, Cecilia N

    2015-01-01

    Protein phosphorylation is a reversible post-translational modification where a protein kinase adds a phosphate group to a protein, potentially regulating its function, localization and/or activity. Phosphorylation can affect protein-protein interactions (PPIs), abolishing interaction with previous binding partners or enabling new interactions. Extracting phosphorylation information coupled with PPI information from the scientific literature will facilitate the creation of phosphorylation interaction networks of kinases, substrates and interacting partners, toward knowledge discovery of functional outcomes of protein phosphorylation. Increasingly, PPI databases are interested in capturing the phosphorylation state of interacting partners. We have previously developed the eFIP (Extracting Functional Impact of Phosphorylation) text mining system, which identifies phosphorylated proteins and phosphorylation-dependent PPIs. In this work, we present several enhancements for the eFIP system: (i) text mining for full-length articles from the PubMed Central open-access collection; (ii) the integration of the RLIMS-P 2.0 system for the extraction of phosphorylation events with kinase, substrate and site information; (iii) the extension of the PPI module with new trigger words/phrases describing interactions and (iv) the addition of the iSimp tool for sentence simplification to aid in the matching of syntactic patterns. We enhance the website functionality to: (i) support searches based on protein roles (kinases, substrates, interacting partners) or using keywords; (ii) link protein entities to their corresponding UniProt identifiers if mapped and (iii) support visual exploration of phosphorylation interaction networks using Cytoscape. The evaluation of eFIP on full-length articles achieved 92.4% precision, 76.5% recall and 83.7% F-measure on 100 article sections. To demonstrate eFIP for knowledge extraction and discovery, we constructed phosphorylation-dependent interaction

  12. Allometric relationships among body mass, MUZZLE-tail length, and tibia length during the growth of Wistar rats.

    Science.gov (United States)

    Santiago, Hildemberg Agostinho Rocha de; De Pierro, Lucas Rodolfo; Reis, Rafael Menezes; Caluz, Antônio Gabriel Ricardo Engracia; Ribeiro, Victor Barbosa; Volpon, José Batista

    2015-11-01

    To investigate allometric relationships among body mass (BM), muzzle-tail length (MTL), and tibia length (TL) in Wistar rats and establish their growth rate change parameters. Eighteen male and 18 female Wistar rats were studied from the 3rd to the 21st week of age. BM, MTL, and TL were measured daily, and relative growth was compared using allometry. A positive correlation between BM and MTL (p<0.05) and BM and TL (p<0.05) was observed. Males and females showed comparable curves; however, females had turning points at a younger age. The allometric relationship between BM and MTL presented a regular increase until reaching a mass of 351 g (males) and 405 g (females). BM and TL showed an initial increase until 185 g (males) and 182 g (females), and then reached a plateau that finished at 412 g (males) and 334 g (females), to display another increase. The allometric relationship of body mass with animal length and tibia length was comparable for male and female rats, with female rats maturing earlier. Animal longitudinal growth occurred in a single stage. In contrast, tibia length depicted two stages of accelerated growth with an intermediate period of deceleration.

  13. System design description for surface moisture measurement system (SMMS)

    Energy Technology Data Exchange (ETDEWEB)

    Vargo, G.F.

    1996-09-23

    The SMMS has been developed to measure moisture in the top few centimeters of tank waste. The SMMS development was initiated by the preliminary findings of SAR-033, and does not necessarily fulfill any established DQO. After the SAR-033 is released, if no significant changes are made, moisture measurements in the organic waste tanks will rapidly become a DQO. The SMMS was designed to be installed in any 4 inch or larger riser, and to allow maximum adjustability for riser lengths, and is used to deploy a sensor package on the waste surface within a 6 foot radius about the azimuth. The first sensor package will be a neutron probe.

  14. Progress in Long Scale Length Laser-Plasma Interactions

    International Nuclear Information System (INIS)

    Glenzer, S H; Arnold, P; Bardsley, G; Berger, R L; Bonanno, G; Borger, T; Bower, D E; Bowers, M; Bryant, R; Buckman, S.; Burkhart, S C; Campbell, K; Chrisp, M P; Cohen, B I; Constantin, G; Cooper, F; Cox, J; Dewald, E; Divol, L; Dixit, S; Duncan, J; Eder, D; Edwards, J; Erbert, G; Felker, B; Fornes, J; Frieders, G; Froula, D H; Gardner, S D; Gates, C; Gonzalez, M; Grace, S; Gregori, G; Greenwood, A; Griffith, R; Hall, T; Hammel, B A; Haynam, C; Heestand, G; Henesian, M; Hermes, G; Hinkel, D; Holder, J; Holdner, F; Holtmeier, G; Hsing, W; Huber, S; James, T; Johnson, S; Jones, O S; Kalantar, D; Kamperschroer, J H; Kauffman, R; Kelleher, T; Knight, J; Kirkwood, R K; Kruer, W L; Labiak, W; Landen, O L; Langdon, A B; Langer, S; Latray, D; Lee, A; Lee, F D; Lund, D; MacGowan, B; Marshall, S; McBride, J; McCarville, T; McGrew, L; Mackinnon, A J; Mahavandi, S; Manes, K; Marshall, C; Mertens, E; Meezan, N; Miller, G; Montelongo, S; Moody, J D; Moses, E; Munro, D; Murray, J; Neumann, J; Newton, M; Ng, E; Niemann, C; Nikitin, A; Opsahl, P; Padilla, E; Parham, T; Parrish, G; Petty, C; Polk, M; Powell, C; Reinbachs, I; Rekow, V; Rinnert, R; Riordan, B; Rhodes, M.

    2003-01-01

    The first experiments on the National Ignition Facility (NIF) have employed the first four beams to measure propagation and laser backscattering losses in large ignition-size plasmas. Gas-filled targets between 2 mm and 7 mm length have been heated from one side by overlapping the focal spots of the four beams from one quad operated at 351 nm (3ω) with a total intensity of 2 x 10 15 W cm -2 . The targets were filled with 1 atm of CO 2 producing of up to 7 mm long homogeneously heated plasmas with densities of n e = 6 x 10 20 cm -3 and temperatures of T e = 2 keV. The high energy in a NIF quad of beams of 16kJ, illuminating the target from one direction, creates unique conditions for the study of laser plasma interactions at scale lengths not previously accessible. The propagation through the large-scale plasma was measured with a gated x-ray imager that was filtered for 3.5 keV x rays. These data indicate that the beams interact with the full length of this ignition-scale plasma during the last ∼1 ns of the experiment. During that time, the full aperture measurements of the stimulated Brillouin scattering and stimulated Raman scattering show scattering into the four focusing lenses of 6% for the smallest length (∼2 mm). increasing to 12% for ∼7 mm. These results demonstrate the NIF experimental capabilities and further provide a benchmark for three-dimensional modeling of the laser-plasma interactions at ignition-size scale lengths

  15. Educational attainment but not measures of current socioeconomic circumstances are associated with leukocyte telomere length in healthy older men and women.

    Science.gov (United States)

    Steptoe, Andrew; Hamer, Mark; Butcher, Lee; Lin, Jue; Brydon, Lena; Kivimäki, Mika; Marmot, Michael; Blackburn, Elizabeth; Erusalimsky, Jorge D

    2011-10-01

    Low socioeconomic status (SES) may be associated with accelerated biological aging, but findings relating SES with telomere length have been inconsistent. We tested the hypotheses that shorter telomere length and telomerase activity would be related more robustly to education, an early life indicator of socioeconomic position, than to current indicators of socioeconomic circumstances. Healthy men and women aged 53-76 years from the Whitehall II epidemiological cohort provided blood samples from which telomere length was assessed in 448 and telomerase activity in 416. Educational attainment was classified into four levels, while household income and grade of employment were measured as indicators of current socioeconomic circumstances. Age, gender, blood pressure, glycated hemoglobin, high density lipoprotein cholesterol, smoking, body mass index and physical activity were included as covariates. We found that lower educational attainment was associated with shorter telomere length after controlling statistically for biological and behavioral covariates. Neither household income nor employment grade was related to telomere length. The association between telomere length and education remained significant after adjusting for current socioeconomic circumstances. In men, highest levels of telomerase activity were found in the lowest education group. We conclude that low SES defined in terms of education but not current socioeconomic circumstances is associated with shortened telomeres. Low educational attainment may be an indicator of long-term SES trajectories, and be associated with accumulated allostatic load resulting in telomere shortening. Education may also promote problem-solving skills leading to reduced biological stress responsivity, with favorable consequences for biological aging. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Coherent Smith-Purcell radiation as a diagnostic for sub-picosecond electron bunch length

    International Nuclear Information System (INIS)

    Nguyen, D.C.

    1996-01-01

    We suggest a novel technique of measuring sub-picosecond electron bunch length base on coherent Smith-Purcell radiation (SPR) emitted when electrons pass close to the surface of a metal grating. With electron bunch lengths comparable to the grating period, we predict that coherent SPR will be emitted at large angles with respect to direction of beam propagation. As the bunch length shortens, the coherent SPR will be enhanced over the incoherent component that is normally observed at small angles. Furthermore, the angular distribution of the coherent SPR will be shifted toward smaller angles as the bunch length becomes much smaller than the grating period. By measuring the angular distribution of the coherent SPR, one can determine the bunch length of sub-picosecond electron pulses. This new technique is easy to implement and appears capable of measuring femtosecond electron bunch lengths

  17. PC-based arc ignition and arc length control system for gas tungsten arc welding

    International Nuclear Information System (INIS)

    Liu, Y.; Cook, G.E.; Barnett, R.J.; Springfield, J.F.

    1992-01-01

    In this paper, a PC-based digital control system for gas tungsten arc welding (GTAW) is presented. This system controls the arc ignition process, the arc length, and the process of welding termination. A DT2818 made by Data Translation is used for interface and A/D and D/A conversions. The digital I/O ports of the DT2818 are used for control of wirefeed, shield gas, cooling water, welding power supply, etc. The DT2818 is housed in a PC. The welding signals and status are displayed on the screen for in-process monitoring. A user can control the welding process by the keyboard

  18. Matrix continued-fraction calculation of localization length in disordered systems

    International Nuclear Information System (INIS)

    Pastawski, H.M.; Weisz, J.F.

    1983-01-01

    A Matrix Continued-Fraction method is used to study the localization length of the states at the band center of a two dimensional crystals with disorder given by the Anderson model. It is found that exponentially localized states which scale according to the work of Mac Kinnon and Kramer, becomes weakly localized as the disorder becomes weaker, and there is some critical disorder for which the localization length does not saturate with the width of the strips, this confirms the resuts found by Pichard and Sarma. Weakly localized states are also found in one dimension for w/v [pt

  19. Matrix continued-fraction calculation of localization length in disordered systems

    International Nuclear Information System (INIS)

    Pastawski, H.M.; Weisz, J.F.

    1983-01-01

    A Matrix Continued-Fraction method is used to study the localization length of the states at the band center of a two dimensional crystal with disorder given by the Anderson model. It is found that exponentially localized states, which scale according to the work of Mac Kinnon and Kramer, becomes weakly localized as the disorder becomes weaker, and there is some critical disorder for which the localization length does not saturate with the width of the strips, this confirms the results found by Pichard and Sarma. Weakly localized states are also found in one dimension for w/v [pt

  20. A computerized system to measure interproximal alveolar bone levels in epidemiologic, radiographic investigations. II

    International Nuclear Information System (INIS)

    Wouters, F.R.; Frithiof, L.; Soeder, P.Oe.; Hellden, L.; Lavstedt, S.; Salonen, L.

    1988-01-01

    The study was aimed at analyzing intra- and inter-examiner variations in computerized measurement and in non-measurability of alveolar bone level in a cross-sectional, epidemiologic material. At each interproximal tooth surface, alveolar bone height in percentage of root length (B/R) and tooth length (B/T) were determined twice by one examiner and once by a second examiner from X5-magnified periapical radiographs. The overall intra- and inter-examiner variations in measurement were 2.85% and 3.84% of root length and 1.97% and 2.82% of tooth length, respectively. The varations were different for different tooth groups and for different degrees of severity of marginal periodontitis. The overall proportions on non-measurable tooth surfaces varied with examiner from 32% to 39% and from 43% to 48% of the available interproximal tooth surfaces for B/R and B/T, respectively. With regard to the level of reliability, the computerized method reported is appropriate to cross-sectional, epidemiologic investigations from radiographs

  1. EFFECT OF EXERCISE ON CYCLE LENGTH IN ATRIAL-FLUTTER

    NARCIS (Netherlands)

    VANDENBERG, MP; CRIJNS, HJGM; SZABO, BM; BROUWER, J; LIE, KI

    Objective-To examine the effect of exercise on cycle length in atrial flutter. Patients-15 patients with chronic atrial flutter. Seven patients were taking digoxin and six verapamil; two were not taking medication. Methods-All patients underwent bicycle ergometry. Flutter cycle length was measured

  2. PET-CT offers accurate assessment of tumour length in oesophageal malignancy

    International Nuclear Information System (INIS)

    Rollins, K.E.; Lucas, E.; Tewari, N.; James, E.; Hughes, S.; Catton, J.A.

    2015-01-01

    Highlights: • We examine the accuracy of staging modalities in estimating tumour length of oesophageal malignancy. • PET CT correlates most strongly with histopathological length of resected specimen. • Better measure than EUS with OGD correlating poorly. • Potential impact in radiotherapy and surgical resection planning. - Abstract: Introduction: Radiotherapy is increasingly used for both curative and palliative treatment of oesophageal malignancy. Accurate treatment depends on determining tumour location and length. This study assessed the value of PET-CT versus other staging modalities in determining tumour length. Materials and methods: Oesophageal cancer patients who underwent staging with PET/CT and endoscopic ultrasound (EUS) in addition to their diagnostic upper GI endoscopy and subsequent surgical resection were assessed. PET/CT length was obtained retrospectively by using Hermes Hybrid Viewer™ with a 1–5 Standardised Uptake Value grey scale. An SUV of 5 was used as the cut off for determining length. Direct measurement by EUS and OGD were determined. Results: 53 patients underwent PET-CT, EUS, OGD and surgical resection for oesophageal cancer. Overall the correlation between PET-CT and histopathological length was strongest (Pearson r = 0.5977, 95% CI 0.390–0.747) versus EUS (Pearson R = 0.5365, 95% CI 0.311–0.705) and OGD (Pearson r = 0.1574, 95% CI −0.118 to 0.410). After excluding tumours with a significant chemotherapy response, PET-CT length correlated significantly with histopathological length (R = 0.5651, p = 0.0005). In comparison, the correlation between histological length and EUS (R = 0.4637, p = 0.0057) measurement was less significant and this did not correlate with OGD (R = −0.1084, p = 0.5417). Conclusion: Tumour length estimated by PET-CT correlated most strongly with histopathological length of oesophageal malignancy and is the most accurate determinant of tumour length of all the staging modalities. This suggests a

  3. PET-CT offers accurate assessment of tumour length in oesophageal malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Rollins, K.E., E-mail: james.catton@nuh.nhs.uk [Department of Oesophago-Gastric Surgery, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); Lucas, E. [University of Nottingham, Derby Road, Nottingham (United Kingdom); Tewari, N. [Department of Oesophago-Gastric Surgery, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); James, E. [Department of Oncology, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); Hughes, S. [Department of Radiology, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); Catton, J.A. [Department of Oesophago-Gastric Surgery, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom)

    2015-02-15

    Highlights: • We examine the accuracy of staging modalities in estimating tumour length of oesophageal malignancy. • PET CT correlates most strongly with histopathological length of resected specimen. • Better measure than EUS with OGD correlating poorly. • Potential impact in radiotherapy and surgical resection planning. - Abstract: Introduction: Radiotherapy is increasingly used for both curative and palliative treatment of oesophageal malignancy. Accurate treatment depends on determining tumour location and length. This study assessed the value of PET-CT versus other staging modalities in determining tumour length. Materials and methods: Oesophageal cancer patients who underwent staging with PET/CT and endoscopic ultrasound (EUS) in addition to their diagnostic upper GI endoscopy and subsequent surgical resection were assessed. PET/CT length was obtained retrospectively by using Hermes Hybrid Viewer™ with a 1–5 Standardised Uptake Value grey scale. An SUV of 5 was used as the cut off for determining length. Direct measurement by EUS and OGD were determined. Results: 53 patients underwent PET-CT, EUS, OGD and surgical resection for oesophageal cancer. Overall the correlation between PET-CT and histopathological length was strongest (Pearson r = 0.5977, 95% CI 0.390–0.747) versus EUS (Pearson R = 0.5365, 95% CI 0.311–0.705) and OGD (Pearson r = 0.1574, 95% CI −0.118 to 0.410). After excluding tumours with a significant chemotherapy response, PET-CT length correlated significantly with histopathological length (R = 0.5651, p = 0.0005). In comparison, the correlation between histological length and EUS (R = 0.4637, p = 0.0057) measurement was less significant and this did not correlate with OGD (R = −0.1084, p = 0.5417). Conclusion: Tumour length estimated by PET-CT correlated most strongly with histopathological length of oesophageal malignancy and is the most accurate determinant of tumour length of all the staging modalities. This suggests a

  4. Association of Telomere Length with Breast Cancer Prognostic Factors.

    Directory of Open Access Journals (Sweden)

    Kaoutar Ennour-Idrissi

    Full Text Available Telomere length, a marker of cell aging, seems to be affected by the same factors thought to be associated with breast cancer prognosis.To examine associations of peripheral blood cell-measured telomere length with traditional and potential prognostic factors in breast cancer patients.We conducted a cross-sectional analysis of data collected before surgery from 162 breast cancer patients recruited consecutively between 01/2011 and 05/2012, at a breast cancer reference center. Data on the main lifestyle factors (smoking, alcohol consumption, physical activity were collected using standardized questionnaires. Anthropometric factors were measured. Tumor biological characteristics were extracted from pathology reports. Telomere length was measured using a highly reproducible quantitative PCR method in peripheral white blood cells. Spearman partial rank-order correlations and multivariate general linear models were used to evaluate relationships between telomere length and prognostic factors.Telomere length was positively associated with total physical activity (rs = 0.17, P = 0.033; Ptrend = 0.069, occupational physical activity (rs = 0.15, P = 0.054; Ptrend = 0.054 and transportation-related physical activity (rs = 0.19, P = 0.019; P = 0.005. Among post-menopausal women, telomere length remained positively associated with total physical activity (rs = 0.27, P = 0.016; Ptrend = 0.054 and occupational physical activity (rs = 0.26, P = 0.021; Ptrend = 0.056 and was only associated with transportation-related physical activity among pre-menopausal women (rs = 0.27, P = 0.015; P = 0.004. No association was observed between telomere length and recreational or household activities, other lifestyle factors or traditional prognostic factors.Telomeres are longer in more active breast cancer patients. Since white blood cells are involved in anticancer immune responses, these findings suggest that even regular low-intensity physical activity, such as that

  5. Symbolic analysis of spatio-temporal systems: The measurement problem

    International Nuclear Information System (INIS)

    Brown, R.; Tang, Xianzhu; Tracy, E.R.

    1996-01-01

    We consider the problem of measuring physical quantities using time-series observations. The approach taken is to validate theoretical models which are derived heuristically or from first principles. The fitting of parameters in such models constitutes the measurement. This is a basic problem in measurement science and a wide array of tools are available. However, an important gap in the present toolkit exists when the system of interest, and hence the models used, exhibit chaotic or turbulent behavior. The development of reliable schemes for analyzing such signals is necessary before one can claim to have a quantitative understanding of the underlying physics. In experimental situations, the number of independently measured time-series is limited, but the number of dynamical degrees of freedom can be large. In addition, the signals of interest will typically be embedded in a noisy background. In the symbol statistics approach, the time-series is coarse-grained and converted into a long, symbol stream. The probability of occurrence of various symbol sequences of fixed length constitutes the symbol statistics. These statistics contain a wealth of information about the underlying dynamics and, as we shall discuss, can be used to validate models. Previously, we have applied this symbolic approach to low dimensional systems with great success. The symbol statistics are robust up to noise/signal ∼20%. At higher noise levels the symbol statistics are biased, but in a relatively simple manner. By including the noise characteristics into the model, we were able to use the symbol statistics to measure parameters even when signal/noise is ∼ O(1). More recently, we have extended the symbolic approach to spatio-temporal systems. We have considered both coupled-map lattices and the complex Ginzburg-Landau equation. This equation arises generically near the onset of instabilities

  6. Feasibility analysis of large length-scale thermocapillary flow experiment for the International Space Station

    Science.gov (United States)

    Alberts, Samantha J.

    The investigation of microgravity fluid dynamics emerged out of necessity with the advent of space exploration. In particular, capillary research took a leap forward in the 1960s with regards to liquid settling and interfacial dynamics. Due to inherent temperature variations in large spacecraft liquid systems, such as fuel tanks, forces develop on gas-liquid interfaces which induce thermocapillary flows. To date, thermocapillary flows have been studied in small, idealized research geometries usually under terrestrial conditions. The 1 to 3m lengths in current and future large tanks and hardware are designed based on hardware rather than research, which leaves spaceflight systems designers without the technological tools to effectively create safe and efficient designs. This thesis focused on the design and feasibility of a large length-scale thermocapillary flow experiment, which utilizes temperature variations to drive a flow. The design of a helical channel geometry ranging from 1 to 2.5m in length permits a large length-scale thermocapillary flow experiment to fit in a seemingly small International Space Station (ISS) facility such as the Fluids Integrated Rack (FIR). An initial investigation determined the proposed experiment produced measurable data while adhering to the FIR facility limitations. The computational portion of this thesis focused on the investigation of functional geometries of fuel tanks and depots using Surface Evolver. This work outlines the design of a large length-scale thermocapillary flow experiment for the ISS FIR. The results from this work improve the understanding thermocapillary flows and thus improve technological tools for predicting heat and mass transfer in large length-scale thermocapillary flows. Without the tools to understand the thermocapillary flows in these systems, engineers are forced to design larger, heavier vehicles to assure safety and mission success.

  7. Retrieval of Effective Correlation Length and Snow Water Equivalent from Radar and Passive Microwave Measurements

    Directory of Open Access Journals (Sweden)

    Juha Lemmetyinen

    2018-01-01

    Full Text Available Current methods for retrieving SWE (snow water equivalent from space rely on passive microwave sensors. Observations are limited by poor spatial resolution, ambiguities related to separation of snow microstructural properties from the total snow mass, and signal saturation when snow is deep (~>80 cm. The use of SAR (Synthetic Aperture Radar at suitable frequencies has been suggested as a potential observation method to overcome the coarse resolution of passive microwave sensors. Nevertheless, suitable sensors operating from space are, up to now, unavailable. Active microwave retrievals suffer, however, from the same difficulties as the passive case in separating impacts of scattering efficiency from those of snow mass. In this study, we explore the potential of applying active (radar and passive (radiometer microwave observations in tandem, by using a dataset of co-incident tower-based active and passive microwave observations and detailed in situ data from a test site in Northern Finland. The dataset spans four winter seasons with daily coverage. In order to quantify the temporal variability of snow microstructure, we derive an effective correlation length for the snowpack (treated as a single layer, which matches the simulated microwave response of a semi-empirical radiative transfer model to observations. This effective parameter is derived from radiometer and radar observations at different frequencies and frequency combinations (10.2, 13.3 and 16.7 GHz for radar; 10.65, 18.7 and 37 GHz for radiometer. Under dry snow conditions, correlations are found between the effective correlation length retrieved from active and passive measurements. Consequently, the derived effective correlation length from passive microwave observations is applied to parameterize the retrieval of SWE using radar, improving retrieval skill compared to a case with no prior knowledge of snow-scattering efficiency. The same concept can be applied to future radar

  8. Quantitative fluorescence spectroscopy in turbid media using fluorescence differential path length spectroscopy

    NARCIS (Netherlands)

    Amelink, Arjen; Kruijt, Bastiaan; Robinson, Dominic J.; Sterenborg, Henricus J. C. M.

    2008-01-01

    We have developed a new technique, fluorescence differential path length spectroscopy (FDPS), that enables the quantitative investigation of fluorophores in turbid media. FDPS measurements are made with the same probe geometry as differential path length spectroscopy (DPS) measurements. Phantom

  9. Hydrodynamic slip length as a surface property

    Science.gov (United States)

    Ramos-Alvarado, Bladimir; Kumar, Satish; Peterson, G. P.

    2016-02-01

    Equilibrium and nonequilibrium molecular dynamics simulations were conducted in order to evaluate the hypothesis that the hydrodynamic slip length is a surface property. The system under investigation was water confined between two graphite layers to form nanochannels of different sizes (3-8 nm). The water-carbon interaction potential was calibrated by matching wettability experiments of graphitic-carbon surfaces free of airborne hydrocarbon contamination. Three equilibrium theories were used to calculate the hydrodynamic slip length. It was found that one of the recently reported equilibrium theories for the calculation of the slip length featured confinement effects, while the others resulted in calculations significantly hindered by the large margin of error observed between independent simulations. The hydrodynamic slip length was found to be channel-size independent using equilibrium calculations, i.e., suggesting a consistency with the definition of a surface property, for 5-nm channels and larger. The analysis of the individual trajectories of liquid particles revealed that the reason for observing confinement effects in 3-nm nanochannels is the high mobility of the bulk particles. Nonequilibrium calculations were not consistently affected by size but by noisiness in the smallest systems.

  10. Windowing UWB microwave, mm-wave multi-port S-parameter measurements using open-ended excess electrical length

    Directory of Open Access Journals (Sweden)

    Gholamreza Askari

    2017-05-01

    Full Text Available Multi-port measurements are a big challenge in circuits' verification, especially when the frequency increases. This study presents a new technique for measuring S-parameters of multi-port ultra-wideband (UWB microwave and mm-wave circuits. The concepts are based on direct or indirect applying modulated UWB impulse radio in desired bandwidth to the one port of the modified multi-port circuit and gathering the reflected signal in the same port and the output signal in the second port in time domain, and the other ports are left opened with a special designed added electrical length. Then by applying intelligent windowing in time domain to the gathering data, and using fast Fourier transform, the desired S-parameters are extracted. Validation of this technique is verified by design and fabrication of a three-port UWB Wilkinson power divider in 22–30 GHz. The simulation and measurement results of the reflection and transmission S-parameters by using this new technique are very close to those are extracted with the conventional vector network analysers S-parameters measurements and show the ability and the accuracy of this technique.

  11. First-Trimester Crown-Rump Length and Embryonic Volume of Fetuses with Structural Congenital Abnormalities Measured in Virtual Reality: An Observational Study

    Directory of Open Access Journals (Sweden)

    L. Baken

    2017-01-01

    Full Text Available Background. With the introduction of three-dimensional (3D ultrasound it has become possible to measure volumes. The relative increase in embryonic volume (EV is much larger than that of the crown-rump length (CRL over the same time period. We examined whether EV is a better parameter to determine growth restriction in fetuses with structural congenital abnormalities. Study Design, Subjects, and Outcome Measures. CRL and EV were measured using a Virtual Reality (VR system in prospectively collected 3D ultrasound volumes of 56 fetuses diagnosed with structural congenital abnormalities in the first trimester of pregnancy (gestational age 7+5 to 14+5 weeks. Measured CRL and EV were converted to z-scores and to percentages of the expected mean using previously published reference curves of euploid fetuses. The one-sample t-test was performed to test significance. Results. The EV was smaller than expected for GA in fetuses with structural congenital abnormalities (−35%  p<0.001, z-score −1.44  p<0.001, whereas CRL was not (−6.43%  p=0.118, z-score −0.43  p=0.605. Conclusions. CRL is a less reliable parameter to determine growth restriction in fetuses with structural congenital abnormalities as compared with EV. By measuring EV, growth restriction in first-trimester fetuses with structural congenital abnormalities becomes more evident and enables an earlier detection of these cases.

  12. Overview of the Spinal Cord Injury – Quality of Life (SCI-QOL) measurement system

    Science.gov (United States)

    Tulsky, David S.; Kisala, Pamela A.; Victorson, David; Tate, Denise G.; Heinemann, Allen W.; Charlifue, Susan; Kirshblum, Steve C.; Fyffe, Denise; Gershon, Richard; Spungen, Ann M.; Bombardier, Charles H.; Dyson-Hudson, Trevor A.; Amtmann, Dagmar; Z. Kalpakjian, Claire; W. Choi, Seung; Jette, Alan M.; Forchheimer, Martin; Cella, David

    2015-01-01

    Context/Objective The Spinal Cord Injury – Quality of Life (SCI-QOL) measurement system was developed to address the shortage of relevant and psychometrically sound patient reported outcome (PRO) measures available for clinical care and research in spinal cord injury (SCI) rehabilitation. Using a computer adaptive testing (CAT) approach, the SCI-QOL builds on the Patient Reported Outcomes Measurement Information System (PROMIS) and the Quality of Life in Neurological Disorders (Neuro-QOL) initiative. This initial manuscript introduces the background and development of the SCI-QOL measurement system. Greater detail is presented in the additional manuscripts of this special issue. Design Classical and contemporary test development methodologies were employed. Qualitative input was obtained from individuals with SCI and clinicians through interviews, focus groups, and cognitive debriefing. Item pools were field tested in a multi-site sample (n = 877) and calibrated using item response theory methods. Initial reliability and validity testing was performed in a new sample of individuals with traumatic SCI (n = 245). Setting Five Model SCI System centers and one Department of Veterans Affairs Medical Center across the United States. Participants Adults with traumatic SCI. Interventions n/a Outcome Measures n/a Results The SCI-QOL consists of 19 item banks, including the SCI-Functional Index banks, and 3 fixed-length scales measuring physical, emotional, and social aspects of health-related QOL (HRQOL). Conclusion The SCI-QOL measurement system consists of psychometrically sound measures for individuals with SCI. The manuscripts in this special issue provide evidence of the reliability and initial validity of this measurement system. The SCI-QOL also links to other measures designed for a general medical population. PMID:26010962

  13. Speciation of Bactrocera dorsalis complex based on aedeagus length

    International Nuclear Information System (INIS)

    Osamu Iwahashi

    2000-01-01

    A species complex of Bactrocera dorsalis (Hendel) in Southeast Asia is composed of 52 species (Drew and Hancock, 1994) and while some of these species are economically very important, distinguishing them based on morphological characters has been difficult (White and Elson-Harris 1992). Specifically, there is considerable difficulty in differentiating between males of two pairs of sympatric species, B. philippinensis Drew and Hancock/B. occipitalis (Bezzi) in the Philippines and B. carambolae Drew and Hancock/B. papayae Drew and Hancock in Indonesia. This may be, in part, because the evolutionary processes within this species complex are still very dynamic, and that natural hybridisation between sympatric species pairs might be occurring on a regular basis (He and Haymer 1997). Iwaizumi et al. (1997) developed a simple method to differentiate the two sets of sympatric species based on aedeagus lengths. However, these flies had been reared artificially under laboratory conditions and only a small number of specimens (n=5) was used. Consequently, they were not able to obtain a frequency distribution of the aedeagus length for each species. Iwahashi (1998) measured a larger number of wild flies collected on Guimaras Is, Philippines, and found that flies with the aedeagus length of 2.89 mm are B. philippinensis. Iwahashi (1999) also showed that the measurement of the aedeagal length of fruit flies is a reliable characteristic for distinguishing between the 2 sympatric species pairs in the B. dorsalis complex. This being so, it may also be interesting to interpret phylogenetic relationships among B. dorsalis complex species based on the aedeagus length. Thus, aedeagus lengths of different populations of five B. dorsalis complex species are measured and their relationships discussed

  14. The length dependence of the series elasticity of pig bladder smooth muscle

    NARCIS (Netherlands)

    R. van Mastrigt (Ron)

    1988-01-01

    textabstractStrips of urinary bladder smooth muscle were subjected to a series of quick release measurements. Each measurement consisted of several releases and resets to the original length, made during one contraction. The complete length-force characteristic of series elasticity was quantified by

  15. Television Watching and Telomere Length Among Adults in Southwest China.

    Science.gov (United States)

    Xue, Hong-Mei; Liu, Qian-Qian; Tian, Guo; Quan, Li-Ming; Zhao, Yong; Cheng, Guo

    2017-09-01

    To explore the independent associations of sedentary behavior and physical activity with telomere length among Chinese adults. Data on total time of sedentary behavior, screen-based sedentary behavior (including television watching and computer or phone use), moderate to vigorous physical activity, and dietary intake of 518 adults in Chengdu, Guizhou, and Xiamen in China (54.25% women) aged 20 to 70 years were obtained between 2013 and 2015 through questionnaires. Height, weight, and waist circumference were measured to calculate body mass index and percentage of body fat. Telomere length was measured through Southern blot technique. Television watching was inversely related to adjusted telomere length (-71.75 base pair; SE = 34.40; P  = .04). Furthermore, a similar trend between telomere length and television watching was found in the group aged 20 to 40 years after adjusting for all covariates. Adults aged 20 to 40 years in the highest tertile of daily time spent on watching television had 4.0% shorter telomere length than adults in the lowest tertile (P = .03). Although the association is modest, television watching is inversely related to telomere length among Chinese adults, warranting further investigation in large prospective studies.

  16. Commissioning of an electro-optic electron bunch length monitor at FLASH

    International Nuclear Information System (INIS)

    Breunlin, Jonas

    2011-03-01

    The demands on the electron beam qualities for free-electron lasers (FEL) are challenging in terms of high peak currents. At FLASH, the high-gain FEL in Hamburg, longitudinal bunch compression is performed to achieve the requested high charge densities in short bunches. The precise control of the bunch compression process requires advanced diagnostics on the longitudinal bunch profile. The bunch length monitor presented in this thesis is based on a non-destructive detection using the electro-optic effect. The focus is on a compact and reliable system for permanent bunch diagnostics. The monitor provides single-shot measurements of the longitudinal bunch profiles with lengths of a few picoseconds by spectrally encoding their charge distribution. First measurements for characterization purpose have been performed. It has been shown that the monitor is suitable for monitoring the longitudinal bunch profile behind the first bunch compressor at FLASH. Electron bunch profiles with slopes corresponding to a full width half maximum of about 1.4 ps have been detected. That is the intrinsic resolution limit of the utilized method. (orig.)

  17. Relationship between photoreceptor outer segment length and visual acuity in diabetic macular edema.

    Science.gov (United States)

    Forooghian, Farzin; Stetson, Paul F; Meyer, Scott A; Chew, Emily Y; Wong, Wai T; Cukras, Catherine; Meyerle, Catherine B; Ferris, Frederick L

    2010-01-01

    The purpose of this study was to quantify photoreceptor outer segment (PROS) length in 27 consecutive patients (30 eyes) with diabetic macular edema using spectral domain optical coherence tomography and to describe the correlation between PROS length and visual acuity. Three spectral domain-optical coherence tomography scans were performed on all eyes during each session using Cirrus HD-OCT. A prototype algorithm was developed for quantitative assessment of PROS length. Retinal thicknesses and PROS lengths were calculated for 3 parameters: macular grid (6 x 6 mm), central subfield (1 mm), and center foveal point (0.33 mm). Intrasession repeatability was assessed using coefficient of variation and intraclass correlation coefficient. The association between retinal thickness and PROS length with visual acuity was assessed using linear regression and Pearson correlation analyses. The main outcome measures include intrasession repeatability of macular parameters and correlation of these parameters with visual acuity. Mean retinal thickness and PROS length were 298 mum to 381 microm and 30 microm to 32 mum, respectively, for macular parameters assessed in this study. Coefficient of variation values were 0.75% to 4.13% for retinal thickness and 1.97% to 14.01% for PROS length. Intraclass correlation coefficient values were 0.96 to 0.99 and 0.73 to 0.98 for retinal thickness and PROS length, respectively. Slopes from linear regression analyses assessing the association of retinal thickness and visual acuity were not significantly different from 0 (P > 0.20), whereas the slopes of PROS length and visual acuity were significantly different from 0 (P < 0.0005). Correlation coefficients for macular thickness and visual acuity ranged from 0.13 to 0.22, whereas coefficients for PROS length and visual acuity ranged from -0.61 to -0.81. Photoreceptor outer segment length can be quantitatively assessed using Cirrus HD-OCT. Although the intrasession repeatability of PROS

  18. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  19. Effects of preservation method on length and weight of pond raised ...

    African Journals Online (AJOL)

    Length and weight measurements of fish used for taxonomy and determination of length-weight relationship are taken from preserved specimen. This study sets out to investigate the effects of two preservatives, 70% alcohol and 10% formalin and freezing method on the length and weight of preserved specimens of tilapia ...

  20. Systems Measures of Water Distribution System Resilience

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Murray, Regan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walker, La Tonya Nicole [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements to water distribution system modeling tools.

  1. Vertebral scale system to measure canine heart size in radiographs

    International Nuclear Information System (INIS)

    Buchanan, J.W.; Bucheler, J.

    1995-01-01

    A method for measuring canine heart size in radiographs was developed on the basis that there is a good correlation between heart size and body length regardless of the conformation of the thorax. The lengths of the long and short axes of the heart of 100 clinically normal dogs were determined with calipers, and the dimensions were scaled against the length of vertebrae dorsal to the heart beginning with T4. The sum of the long and short axes of the heart expressed as vertebral heart size was 9.7 +/- 0.5 vertebrae. The differences between dogs with a wide or deep thorax, males and females, and right or left lateral recumbency were not significant. The caudal vena cava was 0.75 vertebrae +/- 0.13 in comparison to the length of the vertebra over the tracheal bifurcation

  2. Contingent use of fetal fibronectin testing and cervical length measurement in women with preterm labour.

    Science.gov (United States)

    Audibert, François; Fortin, Suzanne; Delvin, Edgard; Djemli, Anissa; Brunet, Suzanne; Dubé, Johanne; Fraser, William D

    2010-04-01

    To evaluate the contingent use of fetal fibronectin (fFN) testing and cervical length (CL) measurement to predict preterm delivery, and to validate the use of phosphorylated IGFBP-1 as a predictor of preterm delivery. We recruited 71 women with a clinical diagnosis of preterm labour between 24 and 34 weeks, and tested for the presence of fFN and IGFBP-1 in the cervicovaginal secretions of all women immediately before CL measurement. Among the 66 women with complete outcome, four were excluded from the final analysis as two had assessment for fFN but no CL measurement, and another two had CL measured but no screening for fFN. Among 62 women with complete results, the mean gestational age at recruitment was 29.4 +/- 2.5 weeks. Six women (9.6%) delivered within two weeks of assessment, and 14 (22.5%) delivered before 34 weeks. A positive fFN test resulted in a sensitivity of 83%, a specificity of 84%, a positive predictive value of 36%, and a negative predictive value of 98% for delivery within two weeks; for CL contingent use of fFN (in which the test was assumed to be positive if CL contingent use protocol, only one third of women needed fFN screening after CL measurement. In this study, IGFBP-1 screening did not predict preterm delivery and fFN screening provided the best predictive capacity. A policy of contingent use of testing for fFN after CL measurement, or contingent use of CL measurement after fFN screening (depending on available resources) is a promising approach to limit use of resources.

  3. Bond lengths in Cd1-xZnxTe beyond linear laws revisited

    International Nuclear Information System (INIS)

    Koteski, V.; Haas, H.; Holub-Krappe, E.; Ivanovic, N.; Mahnke, H.-E.

    2004-01-01

    We have investigated the development of local bond lengths with composition in the Cd 1-x Zn x Te mixed system by measuring the fine structure in X-ray absorption (EXAFS) at all three constituent atoms. The bond strength is found to dominate over the averaging of the bulk so that the local bond length deviates only slightly from its natural value determined for the pure binary components ZnTe and CdTe, respectively. The deviations are significantly less than predicted by a simple radial force constant model for tetrahedrally co-ordinated binary systems, and the bond-length variation with concentration is significantly non-linear. For the second shell, bimodal anion-anion distances are found while the cation-cation distances can already be described by the virtual crystal approximation. In the diluted regime close to the end-point compounds, we have complemented our experimental work by ab initio calculations based on density functional theory with the WIEN97 program using the linearised augmented plane wave method. Equilibrium atomic lattice positions have been calculated for the substitutional isovalent metal atom in a 32-atom super cell, Zn in the CdTe lattice or Cd in the ZnTe lattice, respectively, yielding good agreement with the atomic distances as determined in our EXAFS experiments

  4. Diagnostic value of newborn foot length to predict gestational age

    Directory of Open Access Journals (Sweden)

    Mutia Farah Fawziah

    2017-08-01

    Full Text Available Background  Identification of gestational age, especially within 48 hours of birth, is crucial for newborns, as the earlier preterm status is detected, the earlier the child can receive optimal management. Newborn foot length is an anthropometric measurement which is easy to perform, inexpensive, and potentially efficient for predicting gestational age. Objective  To analyze the diagnostic value of newborn foot length in predicting gestational age. Methods  This diagnostic study was performed between October 2016 and February 2017 in the High Care Unit of Neonates at Dr. Moewardi General Hospital, Surakarta. A total of 152 newborns were consecutively selected and underwent right foot length measurements before 96 hours of age. The correlation between newborn foot length to classify as full term and gestational age was analyzed with Spearman’s correlation test because of non-normal data distribution. The cut-off point of newborn foot length was calculated by receiver operating characteristic (ROC curve and diagnostic values of newborn foot length were analyzed by 2 x 2 table with SPSS 21.0 software. Results There were no significant differences between male and female newborns in terms of gestational age, birth weight, choronological age, and newborn foot length (P>0.05. Newborn foot length and gestational age had a significant correlation (r=0.53; P=0.000. The optimal cut-off newborn foot length to predict full term status was 7.1 cm. Newborn foot length below 7.1 cm had sensitivity 75%, specificity 98%, positive predictive value 94.3%, negative predictive value 90.6%, positive likelihood ratio 40.5, negative likelihood ratio 0.25, and post-test probability 94.29%, to predict preterm status in newborns. Conclusion  Newborn foot length can be used to predict gestational age, especially for the purpose of differentiating between preterm and full term newborns.

  5. A Small Crack Length Evaluation Technique by Electronic Scanning

    International Nuclear Information System (INIS)

    Cho, Yong Sang; Kim, Jae Hoon

    2009-01-01

    The results of crack evaluation by conventional UT(Ultrasonic Test)is highly depend on the inspector's experience or knowledge of ultrasound. Phased array UT system and its application methods for small crack length evaluation will be a good alternative method which overcome present UT weakness. This study was aimed at checking the accuracy of crack length evaluation method by electronic scanning and discuss about characteristics of electronic scanning for crack length evaluation. Especially ultrasonic phased array with electronic scan technique was used in carrying out both sizing and detect ability of crack as its length changes. The response of ultrasonic phased array was analyzed to obtain the special method of determining crack length without moving the transducer and detectability of crack minimal length and depth from the material. A method of crack length determining by electronic scanning for the small crack is very real method which has it's accuracy and verify the effectiveness of method compared to a conventional crack length determination

  6. Q-FISH measurement of hepatocyte telomere lengths in donor liver and graft after pediatric living-donor liver transplantation: donor age affects telomere length sustainability.

    Directory of Open Access Journals (Sweden)

    Youichi Kawano

    Full Text Available Along with the increasing need for living-donor liver transplantation (LDLT, the issue of organ shortage has become a serious problem. Therefore, the use of organs from elderly donors has been increasing. While the short-term results of LDLT have greatly improved, problems affecting the long-term outcome of transplant patients remain unsolved. Furthermore, since contradictory data have been reported with regard to the relationship between donor age and LT/LDLT outcome, the question of whether the use of elderly donors influences the long-term outcome of a graft after LT/LDLT remains unsettled. To address whether hepatocyte telomere length reflects the outcome of LDLT, we analyzed the telomere lengths of hepatocytes in informative biopsy samples from 12 paired donors and recipients (grafts of pediatric LDLT more than 5 years after adult-to-child LDLT because of primary biliary atresia, using quantitative fluorescence in situ hybridization (Q-FISH. The telomere lengths in the paired samples showed a robust relationship between the donor and grafted hepatocytes (r = 0.765, p = 0.0038, demonstrating the feasibility of our Q-FISH method for cell-specific evaluation. While 8 pairs showed no significant difference between the telomere lengths for the donor and the recipient, the other 4 pairs showed significantly shorter telomeres in the recipient than in the donor. Multiple regression analysis revealed that the donors in the latter group were older than those in the former (p = 0.001. Despite the small number of subjects, this pilot study indicates that donor age is a crucial factor affecting telomere length sustainability in hepatocytes after pediatric LDLT, and that the telomeres in grafted livers may be elongated somewhat longer when the grafts are immunologically well controlled.

  7. Finite fission chain length and symmetry around prompt-criticality

    International Nuclear Information System (INIS)

    Xie Qilin; Yin Yanpeng; Gao Hui; Huang Po; Fang Xiaoqiang

    2012-01-01

    Probability distribution of finite fission chain length was derived by assuming that all neutrons behave identically. Finite fission chain length was also calculated using a zero-dimension Monte-Carlo method based on point kinetics. Then symmetry of finite fission chain length probability distribution around prompt-criticality was deduced, which helps understanding the emission rate of delayed neutrons and initiation of fission chain in super-prompt-critical system. (authors)

  8. Bruch´s membrane thickness in relationship to axial length.

    Directory of Open Access Journals (Sweden)

    Hai Xia Bai

    Full Text Available To assess a potential role of Bruch´s membrane (BM in the biomechanics of the eye, we measured its thickness and the density of retinal pigment epithelium (RPE cells in various ocular regions in eyes of varying axial length.Human globes, enucleated because of an ocular tumor or end-stage glaucoma were prepared for histological examination. Using light microscopy, the histological slides were histomorphometrically examined applying a digitized image analysis system.The study included 104 eyes with a mean axial length of 27.9±3.2 mm (range:22.6mm-36.5mm. In eyes without congenital glaucoma, BM was significantly thickest (P<0.001 at the ora serrata, followed by the posterior pole, the midpoint between equator and posterior pole (MBEPP, and finally the equator. BM thickness was not significantly correlated with axial length (ora serrata: P = 0.93; equator:P = 0.31; MBEPP:P = 0.15; posterior pole:P = 0.35. RPE cell density in the pre-equatorial region (P = 0.02; regression coefficient r = -0.24 and in the retro-equatorial region (P = 0.03; r = -0.22 decreased with longer axial length, while RPE cell density at the ora serrata (P = 0.35, the MBEPP (P = 0.06; r = -0.19 and the posterior pole (P = 0.38 was not significantly correlated with axial length. Highly myopic eyes with congenital glaucoma showed a tendency towards lower BM thickness and lower RPE cell density at all locations.BM thickness, in contrast to scleral and choroidal thickness, was independent of axial length in eyes without congenital glaucoma. In association with an axial elongation associated decrease in the RPE cell density in the midperiphery, the findings support the notion of a biomechanical role BM may play in the process of emmetropization/myopization.

  9. Study on effective MOSFET channel length extracted from gate capacitance

    Science.gov (United States)

    Tsuji, Katsuhiro; Terada, Kazuo; Fujisaka, Hisato

    2018-01-01

    The effective channel length (L GCM) of metal-oxide-semiconductor field-effect transistors (MOSFETs) is extracted from the gate capacitances of actual-size MOSFETs, which are measured by charge-injection-induced-error-free charge-based capacitance measurement (CIEF CBCM). To accurately evaluate the capacitances between the gate and the channel of test MOSFETs, the parasitic capacitances are removed by using test MOSFETs having various channel sizes and a source/drain reference device. A strong linear relationship between the gate-channel capacitance and the design channel length is obtained, from which L GCM is extracted. It is found that L GCM is slightly less than the effective channel length (L CRM) extracted from the measured MOSFET drain current. The reason for this is discussed, and it is found that the capacitance between the gate electrode and the source and drain regions affects this extraction.

  10. Telomere Length – a New Biomarker in Medicine

    Directory of Open Access Journals (Sweden)

    Agnieszka Kozłowska

    2015-12-01

    Full Text Available A number of xenobiotics in the environment and workplace influences on our health and life. Biomarkers are tools for measuring such exposures and their effects in the organism. Nowadays, telomere length, epigenetic changes, mutations and changes in gene expression pattern have become new molecular biomarkers. Telomeres play the role of molecular clock, which influences on expectancy of cell life and thus aging, the formation of damages, development diseases and carcinogenesis. The telomere length depends on mechanisms of replication and the activity of telomerase. Telomere length is currently used as a biomarker of susceptibility and/or exposure. This paper describes the role of telomere length as a biomarker of aging cells, oxidative stress, a marker of many diseases including cancer, and as a marker of environmental and occupational exposure.

  11. The development of crack measurement system using the direct current potential drop method for use in the hot cell

    International Nuclear Information System (INIS)

    Kim, Do-Sik; Ahn, Sang-Bok; Lee, Key-Soon; Kim, Yong-Suk; Kwon, Sang-Chul

    1999-01-01

    The crack length measurement system using the direct current potential drop (DCPD) method was developed for the detection of crack growth initiation and subsequent crack growth. The experimental precautions and data processing procedure required for its application were also described find discussed. The system presented herein was specially built for use in fracture toughness testing of unirradiated or irradiated pressure tube materials from nuclear reactor. The application of this system for fracture toughness determination was illustrated from the test of curved compact tension specimens removed from CANDU reactor pressure tubes. The crack extension was monitored using the DCPD method. It is found that the changes of the potential drop and the changes of the crack length have a linear relationship. The final crack front was marked by heat-tinting after the test and the specimen broken open for determination of the initial and final physical crack length. The physical crack lengths, obtained by the 9-point average method described in ASTM E1737-96 on heat-tinted fracture surface, were used to calibrate the DCPD method for each test on an individual basis by matching the change in voltage to the crack extension. It is found that this system can be recommended for determination of the J-integral resistance (J-R) curve of unirradiated or irradiation materials in the hot cell, especially when testing at elevated temperature and in the environment chamber or furnace. (author)

  12. Measurement of the magneto-optical correlation length in turbid media

    Science.gov (United States)

    Lenke, Ralf; Eisenmann, Christoph; Reinke, Daniel; Maret, Georg

    2002-11-01

    In multiple light scattering media, magnetic field induced circular birefringence (Faraday effect) influences interference effects such as speckle pattern or coherent backscattering. It was predicted that in the diffusive regime the relevant correlation length with respect to the Faraday rotation l*F differs, in general, from the transport mean free path l*. We have experimentally verified the prediction that the ratio l*F/l* equals 2 for Rayleigh scattering and decreases to 1 with increasing scatterer size. We also discuss the influence of the structure factor on l*F.

  13. Estimating age from recapture data: integrating incremental growth measures with ancillary data to infer age-at-length

    Science.gov (United States)

    Eaton, Mitchell J.; Link, William A.

    2011-01-01

    Estimating the age of individuals in wild populations can be of fundamental importance for answering ecological questions, modeling population demographics, and managing exploited or threatened species. Significant effort has been devoted to determining age through the use of growth annuli, secondary physical characteristics related to age, and growth models. Many species, however, either do not exhibit physical characteristics useful for independent age validation or are too rare to justify sacrificing a large number of individuals to establish the relationship between size and age. Length-at-age models are well represented in the fisheries and other wildlife management literature. Many of these models overlook variation in growth rates of individuals and consider growth parameters as population parameters. More recent models have taken advantage of hierarchical structuring of parameters and Bayesian inference methods to allow for variation among individuals as functions of environmental covariates or individual-specific random effects. Here, we describe hierarchical models in which growth curves vary as individual-specific stochastic processes, and we show how these models can be fit using capture–recapture data for animals of unknown age along with data for animals of known age. We combine these independent data sources in a Bayesian analysis, distinguishing natural variation (among and within individuals) from measurement error. We illustrate using data for African dwarf crocodiles, comparing von Bertalanffy and logistic growth models. The analysis provides the means of predicting crocodile age, given a single measurement of head length. The von Bertalanffy was much better supported than the logistic growth model and predicted that dwarf crocodiles grow from 19.4 cm total length at birth to 32.9 cm in the first year and 45.3 cm by the end of their second year. Based on the minimum size of females observed with hatchlings, reproductive maturity was estimated

  14. Fluorescence resonance energy transfer measured by spatial photon migration in CdSe-ZnS quantum dots colloidal systems as a function of concentration

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, G.; Monte, A. F. G.; Reis, A. F.; Messias, D. N. [Laboratório de Espectroscopia Óptica, Instituto de Física, Universidade Federal de Uberlândia, Uberlândia, MG 38400-902 (Brazil)

    2014-11-17

    The study of the spatial photon migration as a function of the concentration brings into attention the problem of the energy transfer in quantum dot embedded systems. By measuring the photon propagation and its spatial dependence, it is possible to understand the whole dynamics in a quantum dot system, and also improve their concentration dependence to maximize energy propagation due to radiative and non-radiative processes. In this work, a confocal microscope was adapted to scan the spatial distribution of photoluminescence from CdSe-ZnS core-shell quantum dots in colloidal solutions. The energy migration between the quantum dots was monitored by the direct measurement of the photon diffusion length, according to the diffusion theory. We observed that the photon migration length decreases by increasing the quantum dot concentration, this kind of behavior has been regarded as a signature of Förster resonance energy transfer in the system.

  15. Length-weight relationship and condition factor of clarias gariepinus ...

    African Journals Online (AJOL)

    Length-Weight relationship and condition factor of Clarias gariepinus and Tilapia Zillii were studiedin lake Alau and Monguno hatchery, both in Borno State of Nigeria, for a period of two weeks. A total of 98 C. gariepinus and 140. T. zillii were measured. The length-weight regression coefficient (b) for both fishes in lake Alau ...

  16. Dorsal Phalloplasty to Preserve Penis Length after Penile Prosthesis Implantation

    Directory of Open Access Journals (Sweden)

    Osama Shaeer

    2017-03-01

    Full Text Available Objectives: Following penile prosthesis implantation (PPI, patients may complain of a decrease in visible penis length. A dorsal phalloplasty defines the penopubic junction by tacking pubic skin to the pubis, revealing the base of the penis. This study aimed to evaluate the efficacy of a dorsal phalloplasty in increasing the visible penis length following PPI. Methods: An inflatable penile prosthesis was implanted in 13 patients with severe erectile dysfunction (ED at the Kamal Shaeer Hospital, Cairo, Egypt, from January 2013 to May 2014. During the surgery, nonabsorbable tacking sutures were used to pin the pubic skin to the pubis through the same penoscrotal incision. Intraoperative penis length was measured before and after the dorsal phalloplasty. Overall patient satisfaction was measured on a 5-point rating scale and patients were requested to subjectively compare their postoperative penis length with memories of their penis length before the onset of ED. Results: Intraoperatively, the dorsal phalloplasty increased the visible length of the erect penis by an average of 25.6%. The average length before and after tacking was 10.2 ± 2.9 cm and 13.7 ± 2.8 cm, respectively (P <0.002. Postoperatively, seven patients (53.8% reported a longer penis, five patients (38.5% reported no change in length and one patient (7.7% reported a slightly shorter penis. The mean overall patient satisfaction score was 4.9 ± 0.3. None of the patients developed postoperative complications. Conclusion: A dorsal phalloplasty during PPI is an effective method of increasing visible penis length, therefore minimising the impression of a shorter penis after implantation.

  17. The design of visible system for improving the measurement accuracy of imaging points

    Science.gov (United States)

    Shan, Qiu-sha; Li, Gang; Zeng, Luan; Liu, Kai; Yan, Pei-pei; Duan, Jing; Jiang, Kai

    2018-02-01

    It has a widely applications in robot vision and 3D measurement for binocular stereoscopic measurement technology. And the measure precision is an very important factor, especially in 3D coordination measurement, high measurement accuracy is more stringent to the distortion of the optical system. In order to improving the measurement accuracy of imaging points, to reducing the distortion of the imaging points, the optical system must be satisfied the requirement of extra low distortion value less than 0.1#65285;, a transmission visible optical lens was design, which has characteristic of telecentric beam path in image space, adopted the imaging model of binocular stereo vision, and imaged the drone at the finity distance. The optical system was adopted complex double Gauss structure, and put the pupil stop on the focal plane of the latter groups, maked the system exit pupil on the infinity distance, and realized telecentric beam path in image space. The system mainly optical parameter as follows: the system spectrum rangement is visible light wave band, the optical effective length is f '=30mm, the relative aperture is 1/3, and the fields of view is 21°. The final design results show that the RMS value of the spread spots of the optical lens in the maximum fields of view is 2.3μm, which is less than one pixel(3.45μm) the distortion value is less than 0.1%, the system has the advantage of extra low distortion value and avoids the latter image distortion correction; the proposed modulation transfer function of the optical lens is 0.58(@145 lp/mm), the imaging quality of the system is closed to the diffraction limited; the system has simply structure, and can satisfies the requirements of the optical indexes. Ultimately, based on the imaging model of binocular stereo vision was achieved to measuring the drone at the finity distance.

  18. Universal and idiosyncratic characteristic lengths in bacterial genomes

    Science.gov (United States)

    Junier, Ivan; Frémont, Paul; Rivoire, Olivier

    2018-05-01

    In condensed matter physics, simplified descriptions are obtained by coarse-graining the features of a system at a certain characteristic length, defined as the typical length beyond which some properties are no longer correlated. From a physics standpoint, in vitro DNA has thus a characteristic length of 300 base pairs (bp), the Kuhn length of the molecule beyond which correlations in its orientations are typically lost. From a biology standpoint, in vivo DNA has a characteristic length of 1000 bp, the typical length of genes. Since bacteria live in very different physico-chemical conditions and since their genomes lack translational invariance, whether larger, universal characteristic lengths exist is a non-trivial question. Here, we examine this problem by leveraging the large number of fully sequenced genomes available in public databases. By analyzing GC content correlations and the evolutionary conservation of gene contexts (synteny) in hundreds of bacterial chromosomes, we conclude that a fundamental characteristic length around 10–20 kb can be defined. This characteristic length reflects elementary structures involved in the coordination of gene expression, which are present all along the genome of nearly all bacteria. Technically, reaching this conclusion required us to implement methods that are insensitive to the presence of large idiosyncratic genomic features, which may co-exist along these fundamental universal structures.

  19. Electron Bunch Length Diagnostic With Coherent Smith-Purcell Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, D.C.

    1997-05-12

    The authors have designed a new technique for measuring subpicosecond electron bunch lengths using coherent Smith-Purcell radiation. This new diagnostic technique involves passing the electron beam in close proximity of a grating with a period comparable to the electron bunch length. The emitted Smith-Purcell radiation will have a coherent component whose angular position and distribution are directly related to the electron bunch length and longitudinal profile, respectively. This new diagnostic technique is inherently simple, inexpensive and non-intercepting. The authors show that the new technique is also scaleable to femtosecond regime.

  20. Electron Bunch Length Diagnostic With Coherent Smith-Purcell Radiation

    International Nuclear Information System (INIS)

    Nguyen, D.C.

    1997-01-01

    The authors have designed a new technique for measuring subpicosecond electron bunch lengths using coherent Smith-Purcell radiation. This new diagnostic technique involves passing the electron beam in close proximity of a grating with a period comparable to the electron bunch length. The emitted Smith-Purcell radiation will have a coherent component whose angular position and distribution are directly related to the electron bunch length and longitudinal profile, respectively. This new diagnostic technique is inherently simple, inexpensive and non-intercepting. The authors show that the new technique is also scaleable to femtosecond regime

  1. Neutron scattering lengths of 3He

    International Nuclear Information System (INIS)

    Alfimenkov, V.P.; Akopian, G.G.; Wierzbicki, J.; Govorov, A.M.; Pikelner, L.B.; Sharapov, E.I.

    1976-01-01

    The total neutron scattering cross-section of 3 He has been measured in the neutron energy range from 20 meV to 2 eV. Together with the known value of coherent scattering amplitude it leads to the two sts of n 3 He scattering lengths

  2. System Entropy Measurement of Stochastic Partial Differential Systems

    Directory of Open Access Journals (Sweden)

    Bor-Sen Chen

    2016-03-01

    Full Text Available System entropy describes the dispersal of a system’s energy and is an indication of the disorder of a physical system. Several system entropy measurement methods have been developed for dynamic systems. However, most real physical systems are always modeled using stochastic partial differential dynamic equations in the spatio-temporal domain. No efficient method currently exists that can calculate the system entropy of stochastic partial differential systems (SPDSs in consideration of the effects of intrinsic random fluctuation and compartment diffusion. In this study, a novel indirect measurement method is proposed for calculating of system entropy of SPDSs using a Hamilton–Jacobi integral inequality (HJII-constrained optimization method. In other words, we solve a nonlinear HJII-constrained optimization problem for measuring the system entropy of nonlinear stochastic partial differential systems (NSPDSs. To simplify the system entropy measurement of NSPDSs, the global linearization technique and finite difference scheme were employed to approximate the nonlinear stochastic spatial state space system. This allows the nonlinear HJII-constrained optimization problem for the system entropy measurement to be transformed to an equivalent linear matrix inequalities (LMIs-constrained optimization problem, which can be easily solved using the MATLAB LMI-toolbox (MATLAB R2014a, version 8.3. Finally, several examples are presented to illustrate the system entropy measurement of SPDSs.

  3. A high-stability non-contact dilatometer for low-amplitude temperature-modulated measurements

    Energy Technology Data Exchange (ETDEWEB)

    Luckabauer, Martin; Sprengel, Wolfgang; Würschum, Roland [Institute of Materials Physics, Graz University of Technology, A-8010 Graz (Austria)

    2016-07-15

    Temperature modulated thermophysical measurements can deliver valuable insights into the phase transformation behavior of many different materials. While especially for non-metallic systems at low temperatures numerous powerful methods exist, no high-temperature device suitable for modulated measurements of bulk metallic alloy samples is available for routine use. In this work a dilatometer for temperature modulated isothermal and non-isothermal measurements in the temperature range from room temperature to 1300 K is presented. The length measuring system is based on a two-beam Michelson laser interferometer with an incremental resolution of 20 pm. The non-contact measurement principle allows for resolving sinusoidal length change signals with amplitudes in the sub-500 nm range and physically decouples the length measuring system from the temperature modulation and heating control. To demonstrate the low-amplitude capabilities, results for the thermal expansion of nickel for two different modulation frequencies are presented. These results prove that the novel method can be used to routinely resolve length-change signals of metallic samples with temperature amplitudes well below 1 K. This high resolution in combination with the non-contact measurement principle significantly extends the application range of modulated dilatometry towards high-stability phase transformation measurements on complex alloys.

  4. Is routine transvaginal cervical length measurement cost-effective in a population where the risk of spontaneous preterm birth is low?

    Science.gov (United States)

    Crosby, David A; Miletin, Jan; Semberova, Jana; Daly, Sean

    2016-12-01

    A recent meta-analysis has suggested that routine measurement of the cervical length should be performed in conjunction with the anomaly scan to identify a group of women at increased risk of preterm delivery. We decided to investigate whether this recommendation is justifiable in a population where the risk of preterm birth is low. We reviewed 12 years of obstetric data from the Coombe Women and Infants University Hospital. Relative risks of adverse outcomes from the randomized controlled trial were applied and we extrapolated the possible numbers of women requiring intervention. We then used published neonatal data to estimate the cost of neonatal care and estimated the costs of providing the service. Over 12 years from 2000 until 2011, there were 94 646 singleton deliveries, 1776 happening before 34 weeks. Spontaneous onset occurred in 882 (49.7%) of this group. These 882 births were studied. If we apply the figures from a randomized controlled trial, 1609 women (1.7% from our total population) would be expected to have a cervical length 15 mm. If we gave vaginal progesterone to all women with a sonographically short cervix, we would reduce the delivery rate before 34 weeks by 27.7%. The annual costs of providing the service were estimated to be €109 249 and the cost of immediate neonatal care was estimated to be €380 514. Given the implications associated with preterm delivery, routine measurement of cervical length at the time of the anomaly scan may be justifiable from a cost point of view in a population where the risk of preterm birth is low. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  5. Queue-length balance equations in multiclass multiserver queues and their generalizations

    NARCIS (Netherlands)

    Boon, M.A.A.; Boxma, O.J.; Kella, O.; Miyazawa, M.

    2017-01-01

    A classical result for the steady-state queue-length distribution of single-class queueing systems is the following: The distribution of the queue length just before an arrival epoch equals the distribution of the queue length just after a departure epoch. The constraint for this result to be valid

  6. Queue-length balance equations in multiclass multiserver queues and their generalizations

    NARCIS (Netherlands)

    Boon, M.; Boxma, O.J.; Kella, O.; Miyazawa, M.

    2017-01-01

    A classical result for the steady-state queue-length distribution of single-class queueing systems is the following: the distribution of the queue length just before an arrival epoch equals the distribution of the queue length just after a departure epoch. The constraint for this result to be valid

  7. Application in measurements of SKODA-OZES mobile measuring system

    International Nuclear Information System (INIS)

    Grof, V.; Drab, F.; Icha, K.

    A mobile digital measuring system was built at SKODA - Energeticke strojirenstvi based on digital information system CIS 3000 with the ADT 4100 computer. The system can operate in the BCS or in the RTE-C mode. Two programs are briefly described written for the purpose of measurements. The following applications of the system were tried: testing the reactivity meter on the reactor model, demonstration measurement of the temperature of the medium and display of values on the monitor, measurement of the temperature of the lid of the pressure vessel of the WWER-440 reactor during overlaying and measurement and the adaptive control of band thickness on a KVARTO 200 rolling mill. The measurement system is expected to be used in nuclear power plants and experimental reactors. (M.D.)

  8. Bond length variation in Zn substituted NiO studied from extended X-ray absorption fine structure

    Science.gov (United States)

    Singh, S. D.; Poswal, A. K.; Kamal, C.; Rajput, Parasmani; Chakrabarti, Aparna; Jha, S. N.; Ganguli, Tapas

    2017-06-01

    Bond length behavior for Zn substituted NiO is determined through extended x-ray absorption fine structure (EXAFS) measurements performed at ambient conditions. We report bond length value of 2.11±0.01 Å for Zn-O of rock salt (RS) symmetry, when Zn is doped in RS NiO. Bond length for Zn substituted NiO RS ternary solid solutions shows relaxed behavior for Zn-O bond, while it shows un-relaxed behavior for Ni-O bond. These observations are further supported by first-principles calculations. It is also inferred that Zn sublattice remains nearly unchanged with increase in lattice parameter. On the other hand, Ni sublattice dilates for Zn compositions up to 20% to accommodate increase in the lattice parameter. However, for Zn compositions more than 20%, it does not further dilate. It has been attributed to the large disorder that is incorporated in the system at and beyond 20% of Zn incorporation in the cubic RS lattice of ternary solid solutions. For these large percentages of Zn incorporation, the Ni and the Zn atoms re-arrange themselves microscopically about the same nominal bond length rather than systematically increase in magnitude to minimize the energy of the system. This results in an increase in the Debye-Waller factor with increase in the Zn concentration rather than a systematic increase in the bond lengths.

  9. Effect of canal length and curvature on working length alteration with WaveOne reciprocating files.

    Science.gov (United States)

    Berutti, Elio; Chiandussi, Giorgio; Paolino, Davide Salvatore; Scotti, Nicola; Cantatore, Giuseppe; Castellucci, Arnaldo; Pasqualini, Damiano

    2011-12-01

    This study evaluated the working length (WL) modification after instrumentation with WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating files and the incidence of overinstrumentation in relation to the initial WL. Thirty-two root canals of permanent teeth were used. The angles of curvature of the canals were calculated on digital radiographs. The initial WL with K-files was transferred to the matched WaveOne Primary reciprocating files. After glide paths were established with PathFile (Dentsply Maillefer, Ballaigues, Switzerland), canals were shaped with WaveOne Primary referring to the initial WL. The difference between the postinstrumentation canal length and the initial canal length was analyzed by using a fiberoptic inspection microscope. Data were analyzed with a balanced 2-way factorial analysis of variance (P < .05). Referring to the initial WL, 24 of 32 WaveOne Primary files projected beyond the experimental apical foramen (minimum-maximum, 0.14-0.76 mm). A significant decrease in the canal length after instrumentation (95% confidence interval ranging from -0.34 mm to -0.26 mm) was detected. The canal curvature significantly influenced the WL variation (F(1) = 30.65, P < .001). The interaction between the initial canal length and the canal curvature was statistically significant (F(2) = 4.38, P = .014). Checking the WL before preparation of the apical third of the root canal is recommended when using the new WaveOne NiTi single-file system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Ultrasonic thermometry system for measuring very high temperatures in reactor safety experiments

    International Nuclear Information System (INIS)

    Carlson, G.A.; Sullivan, W.H.; Plein, H.G.; Kerley, T.M.

    1979-06-01

    Ultrasonic thermometry has many potential applications in reactor safety experiments, where extremely high temperatures and lack of visual access may preclude the use of conventional diagnostics. This report details ultrasonic thermometry requirements for one such experiment, the molten fuel pool experiment. Sensors, transducers, and signal processing electronics are described in detail. Axial heat transfer in the sensors is modelled and found acceptably small. Measurement errors, calculations of their effect, and ways to minimize them are given. A rotating sensor concept is discussed which holds promise of alleviating sticking problems at high temperature. Applications of ultrasonic thermometry to three in-core experiments are described. In them, five 10-mm-length sensor elements were used to measure axial temperatures in a UO 2 or UO 2 -steel system fission-heated to about 2860 0 C

  11. The length-weight and length-length relationships of bluefish, Pomatomus saltatrix (Linnaeus, 1766) from Samsun, middle Black Sea region

    OpenAIRE

    Özpiçak, Melek; Saygın, Semra; Polat, Nazmi

    2017-01-01

    In this study, length-weight relationship (LWR) and length-length relationship (LLR) of bluefish,Pomatomus saltatrix were determined. A total of 125 specimens were sampled from Samsun, themiddle Black Sea in 2014 fishing season. Bluefish specimens were monthly collected fromcommercial fishing boats from October to December 2014. All captured individuals (N=125) weremeasured to the nearest 0.1 cm for total, fork and standard lengths. The weight of each fish (W)was recorded to the nearest 0.01 ...

  12. Image processing system for the measurement of timber truck loads

    Science.gov (United States)

    Carvalho, Fernando D.; Correia, Bento A. B.; Davies, Roger; Rodrigues, Fernando C.; Freitas, Jose C. A.

    1993-01-01

    The paper industry uses wood as its raw material. To know the quantity of wood in the pile of sawn tree trunks, every truck load entering the plant is measured to determine its volume. The objective of this procedure is to know the solid volume of wood stocked in the plant. Weighing the tree trunks has its own problems, due to their high capacity for absorbing water. Image processing techniques were used to evaluate the volume of a truck load of logs of wood. The system is based on a PC equipped with an image processing board using data flow processors. Three cameras allow image acquisition of the sides and rear of the truck. The lateral images contain information about the sectional area of the logs, and the rear image contains information about the length of the logs. The machine vision system and the implemented algorithms are described. The results being obtained with the industrial prototype that is now installed in a paper mill are also presented.

  13. Cervical Length in Patients at Risk for Placenta Accreta.

    Science.gov (United States)

    Rac, Martha W F; McIntire, Donald D; Wells, C Edward; Moschos, Elysia; Twickler, Diane D

    2017-07-01

    To evaluate cervical length measurements in women with placenta accreta compared to women with a nonadherent low-lying placenta or placenta previa and evaluate this relationship in terms of vaginal bleeding, preterm labor, and preterm birth. We conducted a retrospective cohort study between 1997 and 2011 of gravidas with more than 1 prior cesarean delivery who had a transvaginal ultrasound examination between 24 and 34 weeks for a low-lying placenta or placenta previa. Cervical length was measured from archived images in accordance with national guidelines by a single investigator, who was blinded to outcomes and ultrasound reports. The diagnosis of placental accreta was based on histologic confirmation. For study purposes, preterm birth was defined as less than 36 weeks, and cervical lengths of 3 cm or less were considered short. Standard statistical analyses were used. A total of 125 patients met inclusion criteria. The cohort was divided into patients with (n = 43 [34%]) and without (n = 82 [66%]) placenta accreta and stratified by gestational age at the ultrasound examinations. Women with placenta accreta had shorter cervical length measurements during their 32- to 34-week ultrasound examinations (mean ± SD, 3.23 ± 0.98 versus 3.95 ± 1.0 cm; P accreta had shorter cervical lengths at 32 to 34 weeks than women with a nonadherent low-lying placenta or placenta previa, but this finding did not correlate with a higher risk of vaginal bleeding or preterm labor resulting in preterm birth before 36 weeks. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Telomere length analysis.

    Science.gov (United States)

    Canela, Andrés; Klatt, Peter; Blasco, María A

    2007-01-01

    Most somatic cells of long-lived species undergo telomere shortening throughout life. Critically short telomeres trigger loss of cell viability in tissues, which has been related to alteration of tissue function and loss of regenerative capabilities in aging and aging-related diseases. Hence, telomere length is an important biomarker for aging and can be used in the prognosis of aging diseases. These facts highlight the importance of developing methods for telomere length determination that can be employed to evaluate telomere length during the human aging process. Telomere length quantification methods have improved greatly in accuracy and sensitivity since the development of the conventional telomeric Southern blot. Here, we describe the different methodologies recently developed for telomere length quantification, as well as their potential applications for human aging studies.

  15. Comparative analysis of maximum renal longitudinal length with positional changes on ultrasound with multiplanar reconstructed MR image in Korea Adults

    International Nuclear Information System (INIS)

    Jang, Yun Hee; Cho, Bum Sang; Kang, Min Ho; Kang, Woo Young; Lee, Jisun; Kim, Yook; Lee, Soo Hyun; Lee, Soo Jung; Lee, Jin Yong

    2016-01-01

    The purpose of this study was to determine a suitable position in which the measured length on ultrasound is close to the true renal length obtained through a multiplanar reconstructed MR image. A total of 33 individuals (males: 15, females: 18) without any underlying renal disease were included in the present study. Renal length was measured as the longest axis at the level of the renal hilum in three positions-supine, lateral decubitus, and prone, respectively. With a 3.0 T MR scanner, 3D eTHRIVE was acquired. Subsequently, the maximum longitudinal length of both the kidneys was measured through multiplanar reconstructed MR images. Paired t-test was used to compare the renal length obtained from ultrasonographic measurement with the length obtained through multiplanar reconstructed MR images. Our study demonstrated significant difference between sonographic renal length in three positions and renal length through MRI (p < 0.001). However, the longest longitudinal length of right kidney among the measured three values by ultrasound was statistically similar to the renal length measured by reconstructed MR image. Among them, the lateral decubitus position showed the strongest correlation with true renal length (right: 0.887; left: 0.849). We recommend measurement of the maximum renal longitudinal length in all possible positions on ultrasonography. If not allowed, the best measurement is on the lateral decubitus showing the strongest correlation coefficient with true renal length

  16. Comparative analysis of maximum renal longitudinal length with positional changes on ultrasound with multiplanar reconstructed MR image in Korea Adults

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Yun Hee; Cho, Bum Sang; Kang, Min Ho; Kang, Woo Young; Lee, Jisun; Kim, Yook; Lee, Soo Hyun; Lee, Soo Jung [Dept. of Radiology, Chungbuk National University Hospital, Cheongju (Korea, Republic of); Lee, Jin Yong [Public Health Medical Service, Seoul National University Boramae Medical Center, Seoul (Korea, Republic of)

    2016-07-15

    The purpose of this study was to determine a suitable position in which the measured length on ultrasound is close to the true renal length obtained through a multiplanar reconstructed MR image. A total of 33 individuals (males: 15, females: 18) without any underlying renal disease were included in the present study. Renal length was measured as the longest axis at the level of the renal hilum in three positions-supine, lateral decubitus, and prone, respectively. With a 3.0 T MR scanner, 3D eTHRIVE was acquired. Subsequently, the maximum longitudinal length of both the kidneys was measured through multiplanar reconstructed MR images. Paired t-test was used to compare the renal length obtained from ultrasonographic measurement with the length obtained through multiplanar reconstructed MR images. Our study demonstrated significant difference between sonographic renal length in three positions and renal length through MRI (p < 0.001). However, the longest longitudinal length of right kidney among the measured three values by ultrasound was statistically similar to the renal length measured by reconstructed MR image. Among them, the lateral decubitus position showed the strongest correlation with true renal length (right: 0.887; left: 0.849). We recommend measurement of the maximum renal longitudinal length in all possible positions on ultrasonography. If not allowed, the best measurement is on the lateral decubitus showing the strongest correlation coefficient with true renal length.

  17. Understanding the length dependence of molecular junction thermopower

    DEFF Research Database (Denmark)

    Karlström, Sven Olov Harald; Strange, Mikkel; Solomon, Gemma

    2014-01-01

    Thermopower of molecular junctions is sensitive to details in the junction and may increase, decrease, or saturate with increasing chain length, depending on the system. Using McConnell's theory for exponentially suppressed transport together with a simple and easily interpretable tight binding...... model, we show how these different behaviors depend on the molecular backbone and its binding to the contacts. We distinguish between resonances from binding groups or undercoordinated electrode atoms, and those from the periodic backbone. It is demonstrated that while the former gives a length......-independent contribution to the thermopower, possibly changing its sign, the latter determines its length dependence. This means that the question of which orbitals from the periodic chain that dominate the transport should not be inferred from the sign of the thermopower but from its length dependence. We find...

  18. The length of the glaciers in the world

    DEFF Research Database (Denmark)

    Machguth, Horst; Huss, M.; Huss, M.

    2014-01-01

    a fully automated method based on glacier surface slope, distance to the glacier margins and a set of trade-off functions. The method is developed for East Greenland, evaluated for the same area as well as for Alaska, and eventually applied to all ∼ 200000 glaciers around the globe. The evaluation...... highlights accurately calculated glacier length where DEM quality is good (East 10 Greenland) and limited precision on low quality DEMs (parts of Alaska). Measured length of very small glaciers is subject to a certain level of ambiguity. The global calculation shows that only about 1.5% of all glaciers...... are longer than 10km with Bering Glacier (Alaska/Canada) being the longest glacier in the world at a length of 196 km. Based on model output we derive global and regional area-length scaling laws. Differences among regional scaling parameters appear to be related to characteristics of topography and glacier...

  19. Axial Length Variation Impacts on Superficial Retinal Vessel Density and Foveal Avascular Zone Area Measurements Using Optical Coherence Tomography Angiography.

    Science.gov (United States)

    Sampson, Danuta M; Gong, Peijun; An, Di; Menghini, Moreno; Hansen, Alex; Mackey, David A; Sampson, David D; Chen, Fred K

    2017-06-01

    To evaluate the impact of image magnification correction on superficial retinal vessel density (SRVD) and foveal avascular zone area (FAZA) measurements using optical coherence tomography angiography (OCTA). Participants with healthy retinas were recruited for ocular biometry, refraction, and RTVue XR Avanti OCTA imaging with the 3 × 3-mm protocol. The foveal and parafoveal SRVD and FAZA were quantified with custom software before and after correction for magnification error using the Littman and the modified Bennett formulae. Relative changes between corrected and uncorrected SRVD and FAZA were calculated. Forty subjects were enrolled and the median (range) age of the participants was 30 (18-74) years. The mean (range) spherical equivalent refractive error was -1.65 (-8.00 to +4.88) diopters and mean (range) axial length was 24.42 mm (21.27-28.85). Images from 13 eyes were excluded due to poor image quality leaving 67 for analysis. Relative changes in foveal and parafoveal SRVD and FAZA after correction ranged from -20% to +10%, -3% to +2%, and -20% to +51%, respectively. Image size correction in measurements of foveal SRVD and FAZA was greater than 5% in 51% and 74% of eyes, respectively. In contrast, 100% of eyes had less than 5% correction in measurements of parafoveal SRVD. Ocular biometry should be performed with OCTA to correct image magnification error induced by axial length variation. We advise caution when interpreting interocular and interindividual comparisons of SRVD and FAZA derived from OCTA without image size correction.

  20. Measurement of the mass of the top quark using the transverse decay length and lepton transverse momentum techniques

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Christian

    2014-05-02

    A measurement of the mass of the top quark using the transverse momentum of the lepton and decay length of the B-Hadron has been presented. The result is m{sub Top}=(170.4±1.1{sub stat.}±2.3{sub syst.}) GeV. This is compatible with previous measurements of the mass of the top quark, done by either the ATLAS collaboration or other experiments. The total uncertainty on the result of this analysis, Δ{sup total}m{sub Top}=2.6 GeV is larger than results by other measurements. However, with an jet energy scale uncertainty of only Δ{sup Jes}m{sub Top}=0.3 GeV it has one of the smallest uncertainties caused by this source. In a combination of results this will help reducing the total uncertainty on the mass of the top quark. The value of 0.42 on the strength on final state radiation indicates that the simulation underestimates the strength of final state radiation. There is currently work ongoing aiming to publish the results found in this thesis in the context of an official ATLAS publication. Additionally the uncertainties can be compared with those one would obtain by using only one of the two variables. If one considers only the transverse decay length, a statistical error of Δm{sub Top}{sup stat.}=1.7 GeV and a systematic uncertainty of Δm{sub Top}{sup stat.}=7.8 GeV is obtained, dominated by the uncertainty on initial and final state radiation. The statistical uncertainty obtained by using the transverse momentum of the lepton is with Δm{sub Top}{sup stat.}=1.4 GeV a bit lower than the one obtained by the transverse decay length alone but still larger than the one of the presented measurement. The systematic uncertainty obtained is Δm{sub Top}{sup stat.}=2.7 GeV. Combining the two variables is therefore worthwhile compared with using only the transverse momentum of the lepton alone. The dominant uncertainties on the measurement are caused by imperfect knowledge of the simulation parameters, especially the choice of Monte-Carlo generator. Other large

  1. Estimation of the flow resistances exerted in coronary arteries using a vessel length-based method.

    Science.gov (United States)

    Lee, Kyung Eun; Kwon, Soon-Sung; Ji, Yoon Cheol; Shin, Eun-Seok; Choi, Jin-Ho; Kim, Sung Joon; Shim, Eun Bo

    2016-08-01

    Flow resistances exerted in the coronary arteries are the key parameters for the image-based computer simulation of coronary hemodynamics. The resistances depend on the anatomical characteristics of the coronary system. A simple and reliable estimation of the resistances is a compulsory procedure to compute the fractional flow reserve (FFR) of stenosed coronary arteries, an important clinical index of coronary artery disease. The cardiac muscle volume reconstructed from computed tomography (CT) images has been used to assess the resistance of the feeding coronary artery (muscle volume-based method). In this study, we estimate the flow resistances exerted in coronary arteries by using a novel method. Based on a physiological observation that longer coronary arteries have more daughter branches feeding a larger mass of cardiac muscle, the method measures the vessel lengths from coronary angiogram or CT images (vessel length-based method) and predicts the coronary flow resistances. The underlying equations are derived from the physiological relation among flow rate, resistance, and vessel length. To validate the present estimation method, we calculate the coronary flow division over coronary major arteries for 50 patients using the vessel length-based method as well as the muscle volume-based one. These results are compared with the direct measurements in a clinical study. Further proving the usefulness of the present method, we compute the coronary FFR from the images of optical coherence tomography.

  2. ESTIMATION OF STATURE BASED ON FOOT LENGTH

    Directory of Open Access Journals (Sweden)

    Vidyullatha Shetty

    2015-01-01

    Full Text Available BACKGROUND : Stature is the height of the person in the upright posture. It is an important measure of physical identity. Estimation of body height from its segments or dismember parts has important considerations for identifications of living or dead human body or remains recovered from disasters or other similar conditions. OBJECTIVE : Stature is an important indicator for identification. There are numerous means to establish stature and their significance lies in the simplicity of measurement, applicability and accuracy in prediction. Our aim of the study was to review the relationship between foot length and body height. METHODS : The present study reviews various prospective studies which were done to estimate the stature. All the measurements were taken by using standard measuring devices and standard anthropometric techniques. RESULTS : This review shows there is a correlation between stature and foot dimensions it is found to be positive and statistically highly significant. Prediction of stature was found to be most accurate by multiple regression analysis. CONCLUSIONS : Stature and gender estimation can be done by using foot measurements and stud y will help in medico - legal cases in establishing identity of an individual and this would be useful for Anatomists and Anthropologists to calculate stature based on foot length

  3. Otolith Length-Fish Length Relationships of Eleven US Arctic Fish Species and Their Application to Ice Seal Diet Studies

    Science.gov (United States)

    Walker, K. L.; Norcross, B.

    2016-02-01

    The Arctic ecosystem has moved into the spotlight of scientific research in recent years due to increased climate change and oil and gas exploration. Arctic fishes and Arctic marine mammals represent key parts of this ecosystem, with fish being a common part of ice seal diets in the Arctic. Determining sizes of fish consumed by ice seals is difficult because otoliths are often the only part left of the fish after digestion. Otolith length is known to be positively related to fish length. By developing species-specific otolith-body morphometric relationships for Arctic marine fishes, fish length can be determined for fish prey found in seal stomachs. Fish were collected during ice free months in the Beaufort and Chukchi seas 2009 - 2014, and the most prevalent species captured were chosen for analysis. Otoliths from eleven fish species from seven families were measured. All species had strong linear relationships between otolith length and fish total length. Nine species had coefficient of determination values over 0.75, indicating that most of the variability in the otolith to fish length relationship was explained by the linear regression. These relationships will be applied to otoliths found in stomachs of three species of ice seals (spotted Phoca largha, ringed Pusa hispida, and bearded Erignathus barbatus) and used to estimate fish total length at time of consumption. Fish lengths can in turn be used to calculate fish weight, enabling further investigation into ice seal energetic demands. This application will aid in understanding how ice seals interact with fish communities in the US Arctic and directly contribute to diet comparisons among and within ice seal species. A better understanding of predator-prey interactions in the US Arctic will aid in predicting how ice seal and fish species will adapt to a changing Arctic.

  4. Vertebral height as the measure of lesion length in carcinoma of the ...

    African Journals Online (AJOL)

    With the modified tech- nique it was possible to decrease treat- ment length and the number of nor- mal oesophageal mucosa in the treat- ment volume, thereby reducing the chance of treatment-related complica- tions such as strictures and ulceration. Introduction. The majority of patients with car- cinoma of the oesophagus ...

  5. The Length of Child Anxiety Treatment in a Regional Health System.

    Science.gov (United States)

    Whiteside, Stephen P H; Ale, Chelsea M; Young, Brennan; Olsen, Mark W; Biggs, Bridget K; Gregg, Melissa S; Geske, Jennifer R; Homan, Kendra

    2016-12-01

    Anxiety disorders are often undertreated due to unsuccessful dissemination of evidence-based treatments (EBTs). Lack of empirical data regarding the typical length of treatment in clinical settings may hamper the development of clinically relevant protocols. The current study examined billing records for 335 children ages 7-17 years to quantify the treatment received for newly diagnosed anxiety disorders within a regional health system. The vast majority of patients did not receive a sufficient number of appointments to complete the typical cognitive behavioral therapy protocol or reach the sessions introducing exposure. Although half of the sample received pharmacotherapy, the vast majority received fewer follow-up appointments than participants in pharmacotherapy research studies. Further, the type of treatment (i.e., number of sessions and medication) differed depending on utilization of specialty care. These results underscore the need to develop brief and flexible EBT protocols that can be standardized and implemented in community practice.

  6. Bioelectric Signal Measuring System

    Science.gov (United States)

    Guadarrama-Santana, A.; Pólo-Parada, L.; García-Valenzuela, A.

    2015-01-01

    We describe a low noise measuring system based on interdigitated electrodes for sensing bioelectrical signals. The system registers differential voltage measurements in order of microvolts. The base noise during measurements was in nanovolts and thus, the sensing signals presented a very good signal to noise ratio. An excitation voltage of 1Vrms with 10 KHz frequency was applied to an interdigitated capacitive sensor without a material under test and to a mirror device simultaneously. The output signals of both devices was then subtracted in order to obtain an initial reference value near cero volts and reduce parasitic capacitances due to the electronics, wiring and system hardware as well. The response of the measuring system was characterized by monitoring temporal bioelectrical signals in real time of biological materials such as embryo chicken heart cells and bovine suprarenal gland cells.

  7. Bluetooth-based distributed measurement system

    International Nuclear Information System (INIS)

    Tang Baoping; Chen Zhuo; Wei Yuguo; Qin Xiaofeng

    2007-01-01

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit

  8. Bluetooth-based distributed measurement system

    Science.gov (United States)

    Tang, Baoping; Chen, Zhuo; Wei, Yuguo; Qin, Xiaofeng

    2007-07-01

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit.

  9. Bluetooth-based distributed measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Tang Baoping; Chen Zhuo; Wei Yuguo; Qin Xiaofeng [Department of Mechatronics, College of Mechanical Engineering, Chongqing University, Chongqing, 400030 (China)

    2007-07-15

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit.

  10. Analysis of measurement system as the mechatronics system

    International Nuclear Information System (INIS)

    Giniotis, V; Grattan, K T V; Rybokas, M; Brucas, D

    2010-01-01

    The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.

  11. Analysis of measurement system as the mechatronics system

    Energy Technology Data Exchange (ETDEWEB)

    Giniotis, V [Institute of Geodesy, Vilnius Gediminas Technical University, Vilnius, Lithuania, Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania); Grattan, K T V [School of Engineering and Mathematical Sciences Electrical, Electronic and Information Eng, City University, Northampton Square, London EC1V 0HB (United Kingdom); Rybokas, M [Department of Information Technologies, Vilnius Gediminas Technical University, Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania); Brucas, D, E-mail: gi@ap.vtu.l, E-mail: k.t.v.grattan@city.ac.u, E-mail: MRybokas@gama.l, E-mail: domka@ktv.l, E-mail: vg@ai.vgtu.l [Department of Geodesy and Cadastre, Vilnius Gediminas Technical University, Vilnius, Lithuania Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania)

    2010-07-01

    The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.

  12. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    2017-01-01

    We present an economic model of systemic risk in which undercapitalization of the financial sector as a whole is assumed to harm the real economy, leading to a systemic risk externality. Each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall...... of components of SES to predict emerging systemic risk during the financial crisis of 2007–2009....

  13. An efficient chaotic source coding scheme with variable-length blocks

    International Nuclear Information System (INIS)

    Lin Qiu-Zhen; Wong Kwok-Wo; Chen Jian-Yong

    2011-01-01

    An efficient chaotic source coding scheme operating on variable-length blocks is proposed. With the source message represented by a trajectory in the state space of a chaotic system, data compression is achieved when the dynamical system is adapted to the probability distribution of the source symbols. For infinite-precision computation, the theoretical compression performance of this chaotic coding approach attains that of optimal entropy coding. In finite-precision implementation, it can be realized by encoding variable-length blocks using a piecewise linear chaotic map within the precision of register length. In the decoding process, the bit shift in the register can track the synchronization of the initial value and the corresponding block. Therefore, all the variable-length blocks are decoded correctly. Simulation results show that the proposed scheme performs well with high efficiency and minor compression loss when compared with traditional entropy coding. (general)

  14. Electrochemical thermodynamic measurement system

    Science.gov (United States)

    Reynier, Yvan [Meylan, FR; Yazami, Rachid [Los Angeles, CA; Fultz, Brent T [Pasadena, CA

    2009-09-29

    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  15. Telomere length in normal and neoplastic canine tissues.

    Science.gov (United States)

    Cadile, Casey D; Kitchell, Barbara E; Newman, Rebecca G; Biller, Barbara J; Hetler, Elizabeth R

    2007-12-01

    To determine the mean telomere restriction fragment (TRF) length in normal and neoplastic canine tissues. 57 solid-tissue tumor specimens collected from client-owned dogs, 40 samples of normal tissue collected from 12 clinically normal dogs, and blood samples collected from 4 healthy blood donor dogs. Tumor specimens were collected from client-owned dogs during diagnostic or therapeutic procedures at the University of Illinois Veterinary Medical Teaching Hospital, whereas 40 normal tissue samples were collected from 12 control dogs. Telomere restriction fragment length was determined by use of an assay kit. A histologic diagnosis was provided for each tumor by personnel at the Veterinary Diagnostic Laboratory at the University of Illinois. Mean of the mean TRF length for 44 normal samples was 19.0 kilobases (kb; range, 15.4 to 21.4 kb), and the mean of the mean TRF length for 57 malignant tumors was 19.0 kb (range, 12.9 to 23.5 kb). Although the mean of the mean TRF length for tumors and normal tissues was identical, tumor samples had more variability in TRF length. Telomerase, which represents the main mechanism by which cancer cells achieve immortality, is an attractive therapeutic target. The ability to measure telomere length is crucial to monitoring the efficacy of telomerase inhibition. In contrast to many other mammalian species, the length of canine telomeres and the rate of telomeric DNA loss are similar to those reported in humans, making dogs a compelling choice for use in the study of human anti-telomerase strategies.

  16. The compound microscope: optical tube length or parfocalization?

    International Nuclear Information System (INIS)

    Simon, J M; Comastri, S A

    2005-01-01

    In various well-known textbooks for undergraduate students of physics, the compound microscope is described as having a standardized 'optical tube length'. On the other hand, in order to fulfil the parfocalization condition required by the human visual system to understand the relation between what is viewed with and without the microscope, the distance between the object and its image through the objective must remain constant as objectives are interchanged. In this paper, we show that these two requirements are not compatible in microscopes containing a revolver with various objectives and that the 'optical tube length' (which differs from the mechanical tube length) cannot be standardized. Moreover, we consider the Deutsche Industrie Norm (DIN) and the Japanese Industry Standards (JIS) norms employed in the microscope industry for standardization of the object-to-intermediate image distance, the parfocal distance and the mechanical tube length

  17. Local difference measures between complex networks for dynamical system model evaluation.

    Science.gov (United States)

    Lange, Stefan; Donges, Jonathan F; Volkholz, Jan; Kurths, Jürgen

    2015-01-01

    A faithful modeling of real-world dynamical systems necessitates model evaluation. A recent promising methodological approach to this problem has been based on complex networks, which in turn have proven useful for the characterization of dynamical systems. In this context, we introduce three local network difference measures and demonstrate their capabilities in the field of climate modeling, where these measures facilitate a spatially explicit model evaluation.Building on a recent study by Feldhoff et al. [8] we comparatively analyze statistical and dynamical regional climate simulations of the South American monsoon system [corrected]. types of climate networks representing different aspects of rainfall dynamics are constructed from the modeled precipitation space-time series. Specifically, we define simple graphs based on positive as well as negative rank correlations between rainfall anomaly time series at different locations, and such based on spatial synchronizations of extreme rain events. An evaluation against respective networks built from daily satellite data provided by the Tropical Rainfall Measuring Mission 3B42 V7 reveals far greater differences in model performance between network types for a fixed but arbitrary climate model than between climate models for a fixed but arbitrary network type. We identify two sources of uncertainty in this respect. Firstly, climate variability limits fidelity, particularly in the case of the extreme event network; and secondly, larger geographical link lengths render link misplacements more likely, most notably in the case of the anticorrelation network; both contributions are quantified using suitable ensembles of surrogate networks. Our model evaluation approach is applicable to any multidimensional dynamical system and especially our simple graph difference measures are highly versatile as the graphs to be compared may be constructed in whatever way required. Generalizations to directed as well as edge- and node

  18. OPERATIONALANALYSIS OF MECHANICAL CUT-TO-LENGTH FOREST HARVESTING SYSTEM

    Directory of Open Access Journals (Sweden)

    Nilton Cesar Fiedler

    2017-08-01

    Full Text Available ABSTRACT The objective of this research was to conduct an operational analysis of forest harvesting activities in a mechanized of the system cut to length in eucalypt plantations in south of Bahia, to determine the distribution of operation times, productivity, operational efficiency and mechanical availability of two models of harvester and two models of forwarder, evaluating these machines in three modules harvesting methodology through time and motion studies. Auxiliary activities corresponded to the lowest percentages within the operating times (mean 1.9% to 1.8% for harvester and forwarder, already operating activities were those that had the highest percentages. The first shift was presented the worst results of operations for the harvester (average 66.3% and the third shift for the forwarder (55.5%. For the harvester module 1 showed the best result of productive times (average 70.36%. In relation to the forwarder, this same module showed the worst results with unproductive times (average of 22.17%. The availability and mechanical parameters were superior productivity for the forwarder (mean 82.31% and 51.33 m3/h, respectively, as indicators of degree of utilization and operational efficiency were higher in harvester (average 85.01% and 66.41%, respectively. Thus, for the forwarder, the parameters mechanical availability and productivity were higher, while for the harvester, they were the indicators of degree of utilization and operational efficiency

  19. Pulse length of ultracold electron bunches extracted from a laser cooled gas

    Directory of Open Access Journals (Sweden)

    J. G. H. Franssen

    2017-07-01

    Full Text Available We present measurements of the pulse length of ultracold electron bunches generated by near-threshold two-photon photoionization of a laser-cooled gas. The pulse length has been measured using a resonant 3 GHz deflecting cavity in TM110 mode. We have measured the pulse length in three ionization regimes. The first is direct two-photon photoionization using only a 480 nm femtosecond laser pulse, which results in short (∼15 ps but hot (∼104 K electron bunches. The second regime is just-above-threshold femtosecond photoionization employing the combination of a continuous-wave 780 nm excitation laser and a tunable 480 nm femtosecond ionization laser which results in both ultracold (∼10 K and ultrafast (∼25 ps electron bunches. These pulses typically contain ∼103 electrons and have a root-mean-square normalized transverse beam emittance of 1.5 ± 0.1 nm rad. The measured pulse lengths are limited by the energy spread associated with the longitudinal size of the ionization volume, as expected. The third regime is just-below-threshold ionization which produces Rydberg states which slowly ionize on microsecond time scales.

  20. The association between intelligence and telomere length: a longitudinal population based study.

    Directory of Open Access Journals (Sweden)

    Eva M Kingma

    Full Text Available Low intelligence has been associated with poor health and mortality, but underlying mechanisms remain obscure. We hypothesized that low intelligence is associated with accelerated biological ageing as reflected by telomere length; we suggested potential mediation of this association by unhealthy behaviors and low socioeconomic position. The study was performed in a longitudinal population-based cohort study of 895 participants (46.8% males. Intelligence was measured with the Generalized Aptitude-Test Battery at mean age 52.8 years (33-79 years, SD=11.3. Leukocyte telomere length was measured by PCR. Lifestyle and socioeconomic factors were assessed using written self-report measures. Linear regression analyses, adjusted for age, sex, and telomere length measured at the first assessment wave (T1, showed that low intelligence was associated with shorter leukocyte telomere length at approximately 2 years follow-up (beta= .081, t=2.160, p= .031. Nearly 40% of this association was explained by an unhealthy lifestyle, while low socioeconomic position did not add any significant mediation. Low intelligence may be a risk factor for accelerated biological ageing, thereby providing an explanation for its association with poor health and mortality.

  1. Odd Length Contraction

    Science.gov (United States)

    Smarandache, Florentin

    2013-09-01

    Let's denote by VE the speed of the Earth and byVR the speed of the rocket. Both travel in the same direction on parallel trajectories. We consider the Earth as a moving (at a constant speed VE -VR) spacecraft of almost spherical form, whose radius is r and thus the diameter 2r, and the rocket as standing still. The non-proper length of Earth's diameter, as measured by the astronaut is: L = 2 r√{ 1 -|/VE -VR|2 c2 } rocket! Also, let's assume that the astronaut is laying down in the direction of motion. Therefore, he would also shrink, or he would die!

  2. Extended-length fiber optic carbon dioxide monitoring

    Science.gov (United States)

    Delgado-Alonso, Jesus; Lieberman, Robert A.

    2013-05-01

    This paper discusses the design and performance of fiber optic distributed intrinsic sensors for dissolved carbon dioxide, based on the use optical fibers fabricated so that their entire lengths are chemically sensitive. These fibers use a polymer-clad, silica-core structure where the cladding undergoes a large, reversible, change in optical absorbance in the presence of CO2. The local "cladding loss" induced by this change is thus a direct indication of the carbon dioxide concentration in any section of the fiber. To create these fibers, have developed a carbon dioxide-permeable polymer material that adheres well to glass, is physically robust, has a refractive index lower than fused silica, and acts as excellent hosts for a unique colorimetric indicator system that respond to CO2. We have used this proprietary material to produce carbon-dioxide sensitive fibers up to 50 meters long, using commercial optical fiber fabrication techniques. The sensors have shown a measurement range of dissolved CO2 of 0 to 1,450 mg/l (0 to 100% CO2 saturation), limit of detection of 0.3 mg/l and precision of 1.0 mg/l in the 0 to 50 mg/l dissolved CO2 range, when a 5 meter-long sensor fiber segment is used. Maximum fiber length, minimum detectable concentration, and spatial resolution can be adjusted by adjusting indicator concentration and fiber design.

  3. Stability in a long length NbTi CICC

    CERN Document Server

    Bottura, L; Gislon, P; Spadoni, M; Bellucci, P; Muzzi, L; Turtu, S; Catitti, A; Chiarelli, S; Della Corte, A; Di Ferdinando, E

    2001-01-01

    A crucial issue for a superconducting coil in order to be safely used in the magnetic system of a fusion reactor is stability against all foreseen disturbances. To simulate the fusion machine conditions, including off-normal events, e.g. plasma disruptions, the energy deposition has to be spread over a "long length" cable in conduit conductor (CICC) and a background magnetic field is needed. We have therefore designed and built an experiment consisting of an instrumented NbTi test module inserted in a pair of co-axial pulsed copper coils. A 0.6 m diameter superconducting coil provides a background magnetic field up to 3 T. Calibration of the energy inductively coupled between the pulsed coils and the module has been obtained measuring the system temperature increase just after the pulse by means of thermometers positioned along the conductor. Stability vs. operating current I/sub op/ has been examined for different helium temperatures and different background magnetic fields. The finite element code Gandalf f...

  4. Determination of carrier diffusion length in GaN

    Science.gov (United States)

    Hafiz, Shopan; Zhang, Fan; Monavarian, Morteza; Avrutin, Vitaliy; Morkoç, Hadis; Özgür, Ümit; Metzner, Sebastian; Bertram, Frank; Christen, Jürgen; Gil, Bernard

    2015-01-01

    Diffusion lengths of photo-excited carriers along the c-direction were determined from photoluminescence (PL) and cross-sectional cathodoluminescence (CL) measurements in p- and n-type GaN epitaxial layers grown on c-plane sapphire by metal-organic chemical vapor deposition. The investigated samples incorporate a 6 nm thick In0.15Ga0.85N active layer capped with either 500 nm p-GaN or 1500 nm n-GaN. The top GaN layers were etched in steps and PL from the InGaN active region and the underlying layers was monitored as a function of the top GaN thickness upon photo-generation near the surface region by above bandgap excitation. Taking into consideration the absorption in the top GaN layer as well as active and underlying layers, the diffusion lengths at 295 K and at 15 K were measured to be 93 ± 7 nm and 70 ± 7 nm for Mg-doped p-type GaN and 432 ± 30 nm and 316 ± 30 nm for unintentionally doped n-type GaN, respectively, at photogenerated carrier densities of 4.2 × 1018 cm-3 using PL spectroscopy. CL measurements of the unintentionally doped n-type GaN layer at much lower carrier densities of 1017 cm-3 revealed a longer diffusion length of 525 ± 11 nm at 6 K.

  5. Ratio-based lengths of intervals to improve fuzzy time series forecasting.

    Science.gov (United States)

    Huarng, Kunhuang; Yu, Tiffany Hui-Kuang

    2006-04-01

    The objective of this study is to explore ways of determining the useful lengths of intervals in fuzzy time series. It is suggested that ratios, instead of equal lengths of intervals, can more properly represent the intervals among observations. Ratio-based lengths of intervals are, therefore, proposed to improve fuzzy time series forecasting. Algebraic growth data, such as enrollments and the stock index, and exponential growth data, such as inventory demand, are chosen as the forecasting targets, before forecasting based on the various lengths of intervals is performed. Furthermore, sensitivity analyses are also carried out for various percentiles. The ratio-based lengths of intervals are found to outperform the effective lengths of intervals, as well as the arbitrary ones in regard to the different statistical measures. The empirical analysis suggests that the ratio-based lengths of intervals can also be used to improve fuzzy time series forecasting.

  6. Length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces

    Science.gov (United States)

    Al-jebory, Taymaa A.; Das, Simon K.; Usup, Gires; Bakar, Y.; Al-saadi, Ali H.

    2018-04-01

    In this study, length-weight and length-length relationships of common carp (Cyprinus carpio L.) in the middle and southern Iraq provinces were determined. Fish specimens were procured from seven provinces from July to December, 2015. A negative and positive allometric growth pattern was obtained, where the total length (TL) ranged from 25.60 cm to 33.53 cm, and body weight (BW) ranged from 700 g to 1423 g. Meanwhile, the lowest of 1.03 and highest of 3.54 in "b" value was recorded in group F and group C, respectively. Therefore, Fulton condition factor (K) range from 2.57 to 4.94. While, relative condition factor (Kn) was in the ranged of 0.95 to 1.01. A linear relationship between total length (TL) and standard length (SL) among the provinces for fish groups was obtained. The variances in "b" value ranged from 0.10 to 0.93 with correlation coefficient (r2) of 0.02 to 0.97. This research could be used as a guide to study the ecology and biology of common Carp (Cyprinus carpio L.) in the middle and southern Iraq provinces.

  7. A Method for Determining Skeletal Lengths from DXA Images

    Directory of Open Access Journals (Sweden)

    Fogelman Ignac

    2007-11-01

    Full Text Available Abstract Background Skeletal ratios and bone lengths are widely used in anthropology and forensic pathology and hip axis length is a useful predictor of fracture. The aim of this study was to show that skeletal ratios, such as length of femur to height, could be accurately measured from a DXA (dual energy X-ray absorptiometry image. Methods 90 normal Caucasian females, 18–80 years old, with whole body DXA data were used as subjects. Two methods, linear pixel count (LPC and reticule and ruler (RET were used to measure skeletal sizes on DXA images and compared with real clinical measures from 20 subjects and 20 x-rays of the femur and tibia taken in 2003. Results Although both methods were highly correlated, the LPC inter- and intra-observer error was lower at 1.6% compared to that of RET at 2.3%. Both methods correlated positively with real clinical measures, with LPC having a marginally stronger correlation coefficient (r2 = 0.94; r2 = 0.84; average r2 = 0.89 than RET (r2 = 0.86; r2 = 0.84; average r2 = 0.85 with X-rays and real measures respectively. Also, the time taken to use LPC was half that of RET at 5 minutes per scan. Conclusion Skeletal ratios can be accurately and precisely measured from DXA total body scan images. The LPC method is easy to use and relatively rapid. This new phenotype will be useful for osteoporosis research for individuals or large-scale epidemiological or genetic studies.

  8. Mammography: Correlation of pectoral muscle width and the length in the mediolateral oblique view of the breast

    International Nuclear Information System (INIS)

    Spuur, K.; Poulos, A.; Currie, G.; Rickard, M.

    2010-01-01

    Purpose: To investigate the relationship between the width and length of the pectoral muscle in the mediolateral oblique mammogram of the breast. Method: Mammograms reviewed for this study were performed on women undergoing routine mammographic screening with BreastScreen NSW South West, Australia. The study included a total of 2800 randomly selected mediolateral oblique mammograms from examinations taken between July 2004 and September 2006. Measurements of the width and length of the pectoral muscle were recorded. Results: No statistically significant difference was demonstrated between the mean values for right and left width (p = 0.5293) or length (p = 0.2079). Matched pair analysis demonstrated a statistically significant difference width, (p = 0.0069) and length, (p = 0.0369). No relationship could be demonstrated between the width and length of the pectoral muscle, (p = 0.0701). Conclusion: The inability to determine a relationship between the width and length of the pectoral muscle suggests that these criteria should be assessed independently of each other. This new understanding of the presentation of the pectoral muscle will enable clinically relevant redevelopment of current image evaluation systems to include statistically supported mean performance values. Further research is needed to explore the relationship of width and length to other key image evaluation criteria used in mammography image quality evaluation.

  9. Some problems of special theory of relativity. (Concept of relativistic length)

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1977-01-01

    Two available definitions of the concept of length (distance) related (a) to moving the length standard and (b) to sending a light signal (similar to the radar method for measuring distances) are analyzed. Considerations in favour of the preferable use of the (b) definition are discussed. The extension of the (b) definition for fast moving bodies results in the introduction of the definition of relativistic length and volume. The increase of the longitudinal dimensions of fast moving objects is a consequence of the above definition. It should be noted that, e.g., for a rod, the definition corresponds to measurements on the lines orthogonal to the world strip of the given rod. It is shown that the known Michelson-Morley and Throuton-Noble experiments are naturally explained in the framework of the proposed concept of relativistic length. It is also shown that the definition introduced, unlike the conventional one, satisfies the principle of relativity

  10. Morphological observation and length-weight relationship of critically endangered riverine catfish Rita rita (Hamilton).

    Science.gov (United States)

    Amin, M R; Mollah, M F A; Taslima, K; Muhammadullah

    2014-01-15

    The experiment was conducted to investigate the morphological status of the critically endangered riverine catfish Rita rita using morphometric and meristic traits. About 158 species of Rita were collected from the old Brahmaputra river in Mymensingh district and were studied in the laboratory of the Fisheries Biology and Genetics Department, Bangladesh Agricultural University. Measurement of length and weight of Rita were recorded by using measuring scale and electric balance respectively. Significant curvilinear relationship existed between total length and other morphometric characters and between head length and other characters of the head. Relationships between total length and various body measurements of the fish were highly significant (p < 0.01) except the relationship between total length and pelvic fin length of male fish (p < 0.05). In case of meristic characters-dorsal fin rays, pelvic fin rays, pectoral fin rays, anal fin rays, caudal fin rays, number of vertebrae and branchiostegal rays were found to be more or less similar except slight differences. The values of condition factors (k) in the total length body-weight relationships for female and male were found to be 0.41 and 0.38, respectively. The mean values of relative condition factors (kn) were 1.0 and 1.005 for female and male, respectively.

  11. Interior Temperature Measurement Using Curved Mercury Capillary Sensor Based on X-ray Radiography

    Science.gov (United States)

    Chen, Shuyue; Jiang, Xing; Lu, Guirong

    2017-07-01

    A method was presented for measuring the interior temperature of objects using a curved mercury capillary sensor based on X-ray radiography. The sensor is composed of a mercury bubble, a capillary and a fixed support. X-ray digital radiography was employed to capture image of the mercury column in the capillary, and a temperature control system was designed for the sensor calibration. We adopted livewire algorithms and mathematical morphology to calculate the mercury length. A measurement model relating mercury length to temperature was established, and the measurement uncertainty associated with the mercury column length and the linear model fitted by least-square method were analyzed. To verify the system, the interior temperature measurement of an autoclave, which is totally closed, was taken from 29.53°C to 67.34°C. The experiment results show that the response of the system is approximately linear with an uncertainty of maximum 0.79°C. This technique provides a new approach to measure interior temperature of objects.

  12. Detection of an amphiphilic biosample in a paper microchannel based on length.

    Science.gov (United States)

    Chen, Yu-Tzu; Yang, Jing-Tang

    2015-01-01

    We developed a simple method to achieve semiquantitative detection of an amphiphilic biosample through measuring the length of flow on a microfluidic analytical device (μPAD) based on paper. When an amphiphilic sample was dripped into a straight microchannel defined with a printed wax barrier (hydrophobic) on filter paper (hydrophilic), the length of flow was affected by the reciprocal effect between the sample, the filter-paper channel and the wax barrier. The flow length decreased with increasing concentration of an amphiphilic sample because of adsorption of the sample on the hydrophobic barrier. Measurement of the flow length enabled a determination of the concentration of the amphiphilic sample. The several tested samples included surfactants (Tween 20 and Triton X-100), oligonucleotides (DNA), bovine serum albumin (BSA), human albumin, nitrite, glucose and low-density lipoprotein (LDL). The results show that the measurement of the flow length determined directly the concentration of an amphiphilic sample, whereas a non-amphiphilic sample was not amenable to this method. The proposed method features the advantages of small cost, simplicity, convenience, directness, rapidity (<5 min) and requirement of only a small volume (5 μL) of sample, with prospective applications in developing areas and sites near patients for testing at a point of care (POCT).

  13. Longitudinal Beam measurements at the LHC: The LHC Beam Quality Monitor

    CERN Document Server

    Papotti, G; Follin, F; Wehrle, U

    2011-01-01

    The LHC Beam Quality Monitor is a system that measures individual bunch lengths and positions, similarly to the twin system SPS Beam Quality Monitor, from which it was derived. The pattern verification that the system provides is vital during the injection process to verify the correctness of the injected pattern, while the bunch length measurement is fed back to control the longitudinal emittance blow up performed during the energy ramp and provides a general indication of the health of the RF system. The algorithms used, the hardware implementation and the system integration in the LHC control infrastructure are presented in this paper, along with possible improvements.

  14. Determination of nn scattering length from data on nn final state interaction in nd-breakup reaction

    International Nuclear Information System (INIS)

    Konobeevski, E.S.; Mordovskoy, M.V.; Sergeev, V.A.; Potashev, S.I.; Zuev, S.V.

    2006-01-01

    Full text: An experiment is proposed for the high-precision determination of the neutron-neutron scattering length investigating the nn final state interaction in the nd breakup reaction. The singlet pp and nn scattering lengths are very sensitive probes of the NN-interaction, and their difference is a direct measure of charge-symmetry breaking (CSB) of the nuclear force. However CSB is a small effect, and accurate values of the scattering lengths are needed for a theoretical analysis. The proton-proton scattering length is well known from pp-scattering data (a pp = -17.3± 0.4 fm), and its uncertainty is mainly due to a model-dependent procedure of removing Coulomb effects. The neutron-neutron scattering length is determined from the following processes n+d→p+n+n, π - + d → γ +n+n, d+d→ 2 He+n+n by investigating the kinematic region of the nn final-state interaction (FSI) where two neutrons fly with low relative energy. The results obtained by now are characterized by a significant uncertainty in values of a nn ; they are grouped near -16 and -19 fm [1,2], so even the sign of the difference a nn - a pp is uncertain. In this experiment neutron-neutron scattering length is determined by measuring the yield of the nd breakup reaction as a function of the relative energy ε nn =(E 1 +E 2 -2(E 1 E 2 ) 1/2 cosθ)/2 of two neutrons in the FSI region (two neutrons fly in a narrow angular cone) where nn-interaction is strongly revealed. The theory of reactions in 3N system predicts the ε nn dependence of the FSI cross section being sensitive to the value of a nn . The measurements will be made using the neutron channel RADEX at Moscow meson factory of the Institute for Nuclear Research. The momenta and angles of the two emitted neutrons and the energy of the proton will be measured for each breakup event. The measured dependence of the reaction yield on the relative energy of the two neutrons will be compared to results of the Monte Carlo simulation that includes

  15. Relative gut lengths of coral reef butterflyfishes (Pisces: Chaetodontidae)

    KAUST Repository

    Berumen, Michael L.; Pratchett, Morgan S.; Goodman, Brett Alexander

    2011-01-01

    Variation in gut length of closely related animals is known to generally be a good predictor of dietary habits. We examined gut length in 28 species of butterflyfishes (Chaetodontidae), which encompass a wide range of dietary types (planktivores, omnivores, and corallivores). We found general dietary patterns to be a good predictor of relative gut length, although we found high variation among groups and covariance with body size. The longest gut lengths are found in species that exclusively feed on the living tissue of corals, while the shortest gut length is found in a planktivorous species. Although we tried to control for phylogeny, corallivory has arisen multiple times in this family, confounding our analyses. The butterflyfishes, a speciose family with a wide range of dietary habits, may nonetheless provide an ideal system for future work studying gut physiology associated with specialization and foraging behaviors. © 2011 Springer-Verlag.

  16. Relative gut lengths of coral reef butterflyfishes (Pisces: Chaetodontidae)

    KAUST Repository

    Berumen, Michael L.

    2011-06-17

    Variation in gut length of closely related animals is known to generally be a good predictor of dietary habits. We examined gut length in 28 species of butterflyfishes (Chaetodontidae), which encompass a wide range of dietary types (planktivores, omnivores, and corallivores). We found general dietary patterns to be a good predictor of relative gut length, although we found high variation among groups and covariance with body size. The longest gut lengths are found in species that exclusively feed on the living tissue of corals, while the shortest gut length is found in a planktivorous species. Although we tried to control for phylogeny, corallivory has arisen multiple times in this family, confounding our analyses. The butterflyfishes, a speciose family with a wide range of dietary habits, may nonetheless provide an ideal system for future work studying gut physiology associated with specialization and foraging behaviors. © 2011 Springer-Verlag.

  17. An Enhanced Run-Length Encoding Compression Method for Telemetry Data

    Directory of Open Access Journals (Sweden)

    Shan Yanhu

    2017-09-01

    Full Text Available The telemetry data are essential in evaluating the performance of aircraft and diagnosing its failures. This work combines the oversampling technology with the run-length encoding compression algorithm with an error factor to further enhance the compression performance of telemetry data in a multichannel acquisition system. Compression of telemetry data is carried out with the use of FPGAs. In the experiments there are used pulse signals and vibration signals. The proposed method is compared with two existing methods. The experimental results indicate that the compression ratio, precision, and distortion degree of the telemetry data are improved significantly compared with those obtained by the existing methods. The implementation and measurement of the proposed telemetry data compression method show its effectiveness when used in a high-precision high-capacity multichannel acquisition system.

  18. Extending electronic length frequency analysis in R

    DEFF Research Database (Denmark)

    Taylor, M. H.; Mildenberger, Tobias K.

    2017-01-01

    VBGF (soVBGF) requires a more intensive search due to two additional parameters. This work describes the implementation of two optimisation approaches ("simulated annealing" and "genetic algorithm") for growth function fitting using the open-source software "R." Using a generated LFQ data set......Electronic length frequency analysis (ELEFAN) is a system of stock assessment methods using length-frequency (LFQ) data. One step is the estimation of growth from the progression of LFQ modes through time using the von Bertalanffy growth function (VBGF). The option to fit a seasonally oscillating...... of the asymptotic length parameter (L-infinity) are found to have significant effects on parameter estimation error. An outlook provides context as to the significance of the R-based implementation for further testing and development, as well as the general relevance of the method for data-limited stock assessment....

  19. Evaluation of a cut-to-length system implementing fuel reduction treatments on the Coconino National Forest in Arizona

    Science.gov (United States)

    John Klepac; Bob Rummer; Jason Thompson

    2006-01-01

    A Cut-to-Length (CTL) system was evaluated for production and cost while implementing fuel reduction treatments in two stands on the Coconino National Forest in Arizona. Product recovery and fire behavior within each stand after treatment were also examined. Only trees less than 16 inches diameter breast height (DBH) were harvested. After logs were forwarded to a...

  20. Conversion of Chord Length Data into Bubble Size Distribution: Generation of Chord Length Data and the Methodology Comparison

    Energy Technology Data Exchange (ETDEWEB)

    Hien, Hoang Nhan; Euh, D. J.; Song, C. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yun, B. J. [Pusan National University, Busan (Korea, Republic of)

    2012-05-15

    Bubble size and its distribution play an important role in thermal hydrodynamic processes in multiphase flow systems. By using the conductivity or optical probe techniques, the size and distribution of bubbles can only be inferred indirectly from a measured chord length data (CLD). Some methods are proposed to convert a CLD into the bubble size distribution (BSD), and they can be classified into parametric, semi-parametric and non-parametric. Most of methods are derived from the following relation of the conditional probability functions that are established under the geometric constraints: P(y) = {infinity}{integral}0 P(R) P(y|R) dR where P(R) is PDF of bubbles of all sizes R pierced by a probe, and P(y|R) is PDF of chord length y corresponding to bubbles of a specified size R. These methods are limited to flows of bubbles having symmetric shapes, i.e. spherical, ellipsoidal, or capspherical. Although the methods were developed from a common relation, there are no physical bases as well as the lack of experimental data to validate them. In this work, the CLD is generated for comparing different conversion methods. The range of bubble size is determined by the Hinze's theory. The CLDs are applied to numerical backward transforms (NBT), analytical backward transform (ABT), and analytical semi-parametric method using Parzen window estimator (ParzenES) to obtain the BSD. A comparison for the obtained results is performed

  1. Conversion of Chord Length Data into Bubble Size Distribution: Generation of Chord Length Data and the Methodology Comparison

    International Nuclear Information System (INIS)

    Hien, Hoang Nhan; Euh, D. J.; Song, C. H.; Yun, B. J.

    2012-01-01

    Bubble size and its distribution play an important role in thermal hydrodynamic processes in multiphase flow systems. By using the conductivity or optical probe techniques, the size and distribution of bubbles can only be inferred indirectly from a measured chord length data (CLD). Some methods are proposed to convert a CLD into the bubble size distribution (BSD), and they can be classified into parametric, semi-parametric and non-parametric. Most of methods are derived from the following relation of the conditional probability functions that are established under the geometric constraints: P(y) = ∞∫0 P(R) P(y|R) dR where P(R) is PDF of bubbles of all sizes R pierced by a probe, and P(y|R) is PDF of chord length y corresponding to bubbles of a specified size R. These methods are limited to flows of bubbles having symmetric shapes, i.e. spherical, ellipsoidal, or capspherical. Although the methods were developed from a common relation, there are no physical bases as well as the lack of experimental data to validate them. In this work, the CLD is generated for comparing different conversion methods. The range of bubble size is determined by the Hinze's theory. The CLDs are applied to numerical backward transforms (NBT), analytical backward transform (ABT), and analytical semi-parametric method using Parzen window estimator (ParzenES) to obtain the BSD. A comparison for the obtained results is performed

  2. Telomere Length and Mortality

    DEFF Research Database (Denmark)

    Kimura, Masayuki; Hjelmborg, Jacob V B; Gardner, Jeffrey P

    2008-01-01

    Leukocyte telomere length, representing the mean length of all telomeres in leukocytes, is ostensibly a bioindicator of human aging. The authors hypothesized that shorter telomeres might forecast imminent mortality in elderly people better than leukocyte telomere length. They performed mortality...

  3. System and Method for Measuring the Transfer Function of a Guided Wave Device

    Science.gov (United States)

    Froggatt, Mark E. (Inventor); Erdogan, Turan (Inventor)

    2002-01-01

    A method/system are provided for measuring the NxN scalar transfer function elements for an N-port guided wave device. Optical energy of a selected wavelength is generated at a source and directed along N reference optical paths having N reference path lengths. Each reference optical path terminates in one of N detectors such that N reference signals are produced at the N detectors. The reference signals are indicative of amplitude, phase and frequency of the optical energy carried along the N reference optical paths. The optical energy from the source is also directed to the N-ports of the guided wave device and then on to each of the N detectors such that N measurement optical paths are defined between the source and each of the N detectors. A portion of the optical energy is modified in terms of at least one of the amplitude and phase to produce N modified signals at each of the N detectors. At each of the N detectors, each of the N modified signals is combined with a corresponding one of the N reference signals to produce corresponding N combined signals at each of the N detectors. A total of N(sup 2) measurement signals are generated by the N detectors. Each of the N(sup 2) measurement signals is sampled at a wave number increment (Delta)k so that N(sup 2) sampled signals are produced. The NxN transfer function elements are generated using the N(sup 2) sampled signals. Reference and measurement path length constraints are defined such that the N combined signals at each of the N detectors are spatially separated from one another in the time domain.

  4. [Laser Tuning Performance Testing and Optimization in TDLAS Oxygen Measuring Systems].

    Science.gov (United States)

    He, Jun-feng; Hu, Jun; Kan, Rui-feng; Xu, Zhen-yu; Wang, Tao

    2015-03-01

    TDLAS (tunable diode laser absorption spectroscopy) technology, with its unmatched advantages such as high selectivity molecular spectra, fast response, high sensitivity, non-contact measuring, become the preferred scheme for combustion process diagnosis, and can be effectively used for oxygen measuring. DFB (distributed feedback) laser diode with its small size, low power consumption, long service life, narrow linewidth, tunable wavelength has become the main choice of the TDLAS system. Performance of laser tuning characteristics is a key factor restricting TDLAS's measuring performance. According to TDLAS oxygen measuring system's working requirements, a simple experimental method was used to test and analyze tuning characteristics such as wavelength current, power current and wavelength temperature of a 764 nm DFB laser diode in the system. Nonlinear distortion of tuning curves was obvious, which affects oxygen measuring accuracy. The laser spectra's characteristics such as narrow linewidth, high side mode suppression ratio and wide wavelength tuning range are obvious, while its wavelength-current tuning curve with a tuning rate of about 0.023 nm x mA(-1) is not strictly linear. The higher the temperature the greater the threshold current, the PI curve is not strictly linear either. Temperature tuning curve is of good linearity, temperature-wave-length tuning rate keeps constant of about 0.056 nm/DEG C. Temperature tuning nonlinearity can be improved by high temperature control accuracy, and current power nonlinearity can be improved by setting the reference light path. In order to solve the wavelength current tuning nonlinear problems, the method of DA controlling injection current was considered to compensate for non-linear wavelength current tuning according to DFB laser diode tuning mechanism and polynomial fitting of test results. In view of different type of lasers, this method needs only one polynomial fitting process before the system's initial work. The

  5. Association of Donor and Recipient Telomere Length with Clinical Outcomes following Lung Transplantation.

    Science.gov (United States)

    Courtwright, Andrew M; Fried, Sabrina; Villalba, Julian A; Moniodis, Anna; Guleria, Indira; Wood, Isabelle; Milford, Edgar; Mallidi, Hari H; Hunninghake, Gary M; Raby, Benjamin A; Agarwal, Suneet; Camp, Philip C; Rosas, Ivan O; Goldberg, Hilary J; El-Chemaly, Souheil

    2016-01-01

    Patients with short telomere syndromes and pulmonary fibrosis have increased complications after lung transplant. However, the more general impact of donor and recipient telomere length in lung transplant has not been well characterized. This was an observational cohort study of patients who received lung transplant at a single center between January 1st 2012 and January 31st 2015. Relative donor lymphocyte telomere length was measured and classified into long (third tertile) and short (other tertiles). Relative recipient lung telomere length was measured and classified into short (first tertile) and long (other tertiles). Outcome data included survival, need for modification of immunosuppression, liver or kidney injury, cytomegalovirus reactivation, and acute rejection. Recipient lung tissue telomere lengths were measured for 54 of the 79 patients (68.3%) who underwent transplant during the study period. Donor lymphocyte telomeres were measured for 45 (83.3%) of these recipients. Neither long donor telomere length (hazard ratio [HR] = 0.58, 95% confidence interval [CI], 0.12-2.85, p = 0.50) nor short recipient telomere length (HR = 1.01, 95% CI = 0.50-2.05, p = 0.96) were associated with adjusted survival following lung transplant. Recipients with short telomeres were less likely to have acute cellular rejection (23.5% vs. 58.8%, p = 0.02) but were not more likely to have other organ dysfunction. In this small cohort, neither long donor lymphocyte telomeres nor short recipient lung tissue telomeres were associated with adjusted survival after lung transplantation. Larger studies are needed to confirm these findings.

  6. To the problem of the coherence length of neutrons

    International Nuclear Information System (INIS)

    Varga, P.

    1992-11-01

    The challenge of the high accuracy of certain optical measurements, the long coherence length of light provokes one to search for possibilities to enlarge the neutron coherence length. A proposal is made to achieve this by using a five or a four plate Bonse-Hart interferometer. A further problem is, whether the neutron beam is composed of wave packets or of overlapping independent monochromatic waves; it is considered that the former is more likely. (author) 12 refs.; 3 figs

  7. Model of vortex dynamics in superconducting films in two-coil measurements of the coherence length

    Science.gov (United States)

    Lemberger, Thomas; Loh, Yen Lee

    In two-coil measurements on superconducting films, a magnetic field from a small coil is applied to the center of the film. When the amplitude of the ac field is increased, the film undergoes a transition from the ``Meissner'' state to a state with vortices and antivortices. Ultimately, the vortex density matches the applied magnetic field and field screening is negligible. Experimentally, the field at the transition is related to the superconducting coherence length, although a full theory of the relationship is lacking. We show that the mutual inductance between drive and pickup coils, on opposite sides of the film, as a function of ac field amplitude is well-described by a phenomenological model in which vortices and antivortices appear together in the film at the radius where the induced supercurrent is strongest, and then they move through a landscape of moderately strong vortex pinning sites. Work at OSU supported by DOE-Basic Energy Sciences through Grant No. FG02-08ER46533.

  8. Fine Mapping of QUICK ROOTING 1 and 2, Quantitative Trait Loci Increasing Root Length in Rice.

    Science.gov (United States)

    Kitomi, Yuka; Nakao, Emari; Kawai, Sawako; Kanno, Noriko; Ando, Tsuyu; Fukuoka, Shuichi; Irie, Kenji; Uga, Yusaku

    2018-02-02

    The volume that the root system can occupy is associated with the efficiency of water and nutrient uptake from soil. Genetic improvement of root length, which is a limiting factor for root distribution, is necessary for increasing crop production. In this report, we describe identification of two quantitative trait loci (QTLs) for maximal root length, QUICK ROOTING 1 ( QRO1 ) on chromosome 2 and QRO2 on chromosome 6, in cultivated rice ( Oryza sativa L.). We measured the maximal root length in 26 lines carrying chromosome segments from the long-rooted upland rice cultivar Kinandang Patong in the genetic background of the short-rooted lowland cultivar IR64. Five lines had longer roots than IR64. By rough mapping of the target regions in BC 4 F 2 populations, we detected putative QTLs for maximal root length on chromosomes 2, 6, and 8. To fine-map these QTLs, we used BC 4 F 3 recombinant homozygous lines. QRO1 was mapped between markers RM5651 and RM6107, which delimit a 1.7-Mb interval on chromosome 2, and QRO2 was mapped between markers RM20495 and RM3430-1, which delimit an 884-kb interval on chromosome 6. Both QTLs may be promising gene resources for improving root system architecture in rice. Copyright © 2018 Kitomi et al.

  9. Fine Mapping of QUICK ROOTING 1 and 2, Quantitative Trait Loci Increasing Root Length in Rice

    Directory of Open Access Journals (Sweden)

    Yuka Kitomi

    2018-02-01

    Full Text Available The volume that the root system can occupy is associated with the efficiency of water and nutrient uptake from soil. Genetic improvement of root length, which is a limiting factor for root distribution, is necessary for increasing crop production. In this report, we describe identification of two quantitative trait loci (QTLs for maximal root length, QUICK ROOTING 1 (QRO1 on chromosome 2 and QRO2 on chromosome 6, in cultivated rice (Oryza sativa L.. We measured the maximal root length in 26 lines carrying chromosome segments from the long-rooted upland rice cultivar Kinandang Patong in the genetic background of the short-rooted lowland cultivar IR64. Five lines had longer roots than IR64. By rough mapping of the target regions in BC4F2 populations, we detected putative QTLs for maximal root length on chromosomes 2, 6, and 8. To fine-map these QTLs, we used BC4F3 recombinant homozygous lines. QRO1 was mapped between markers RM5651 and RM6107, which delimit a 1.7-Mb interval on chromosome 2, and QRO2 was mapped between markers RM20495 and RM3430-1, which delimit an 884-kb interval on chromosome 6. Both QTLs may be promising gene resources for improving root system architecture in rice.

  10. Self-assembling block copolymer systems involving competing length scales : A route toward responsive materials

    NARCIS (Netherlands)

    Nap, R; Erukhimovich, [No Value; ten Brinke, G; Erukhimovich, Igor

    2004-01-01

    The phase behavior of block copolymers melts involving competing length scales, i.e., able to microphase separate on two different length scales, is theoretically investigated using a self-consistent field approach. The specific block copolymers studied consist of a linear A-block linked to an

  11. A Main Ring bunch length monitor by detecting two frequency components of the beam

    International Nuclear Information System (INIS)

    Ieiri, T.; Jackson, G.

    1989-01-01

    The bunch length is measured by detecting two revolution frequency harmonics of the beam and taking the ratio of their amplitudes. Two heterodyne receivers have been made to direct them, one at 53MHz and the other at 159MHz. These signals are picked-up by a stripline detector. An analog circuit provides a signal proportional to the bunch length. The monitor measures variation of the bunch length as a function of time in the Main Ring. The measured signal, which sometimes shows that the bunches are tumbling in phase space, can be damped by feedback to the RF amplitude modulator. 9 refs., 12 figs., 1 tab

  12. “Oversized” Penile Length In The Black People; Myth Or Reality ...

    African Journals Online (AJOL)

    ... penile lengths, and flaccid penile lengths, were measured in 115 adult men of the Black race in Nigeria. The results were compared with reported similar main studies on people of other races, which were accessible to the authors. These studies were done in Italy, Greece, Korea, Britain, and the United States of America.

  13. Short Rayleigh length free electron lasers

    Directory of Open Access Journals (Sweden)

    W. B. Colson

    2006-03-01

    Full Text Available Conventional free electron laser (FEL oscillators minimize the optical mode volume around the electron beam in the undulator by making the resonator Rayleigh length about one third to one half of the undulator length. This maximizes gain and beam-mode coupling. In compact configurations of high-power infrared FELs or moderate power UV FELs, the resulting optical intensity can damage the resonator mirrors. To increase the spot size and thereby reduce the optical intensity at the mirrors below the damage threshold, a shorter Rayleigh length can be used, but the FEL interaction is significantly altered. We model this interaction using a coordinate system that expands with the rapidly diffracting optical mode from the ends of the undulator to the mirrors. Simulations show that the interaction of the strongly focused optical mode with a narrow electron beam inside the undulator distorts the optical wave front so it is no longer in the fundamental Gaussian mode. The simulations are used to study how mode distortion affects the single-pass gain in weak fields, and the steady-state extraction in strong fields.

  14. Examining Hurricane Track Length and Stage Duration Since 1980

    Science.gov (United States)

    Fandrich, K. M.; Pennington, D.

    2017-12-01

    Each year, tropical systems impact thousands of people worldwide. Current research shows a correlation between the intensity and frequency of hurricanes and the changing climate. However, little is known about other prominent hurricane features. This includes information about hurricane track length (the total distance traveled from tropical depression through a hurricane's final category assignment) and how this distance may have changed with time. Also unknown is the typical duration of a hurricane stage, such as tropical storm to category one, and if the time spent in each stage has changed in recent decades. This research aims to examine changes in hurricane stage duration and track lengths for the 319 storms in NOAA's National Ocean Service Hurricane Reanalysis dataset that reached Category 2 - 5 from 1980 - 2015. Based on evident ocean warming, it is hypothesized that a general increase in track length with time will be detected, thus modern hurricanes are traveling a longer distance than past hurricanes. It is also expected that stage durations are decreasing with time so that hurricanes mature faster than in past decades. For each storm, coordinates are acquired at 4-times daily intervals throughout its duration and track lengths are computed for each 6-hour period. Total track lengths are then computed and storms are analyzed graphically and statistically by category for temporal track length changes. The stage durations of each storm are calculated as the time difference between two consecutive stages. Results indicate that average track lengths for Cat 2 and 3 hurricanes are increasing through time. These findings show that these hurricanes are traveling a longer distance than earlier Cat 2 and 3 hurricanes. In contrast, average track lengths for Cat 4 and 5 hurricanes are decreasing through time, showing less distance traveled than earlier decades. Stage durations for all Cat 2, 4 and 5 storms decrease through the decades but Cat 3 storms show a

  15. Analysis of Queue-Length Dependent Vacations and P-Limited Service in BMAP/G/1/N Systems: Stationary Distributions and Optimal Control

    Directory of Open Access Journals (Sweden)

    A. D. Banik

    2013-01-01

    Full Text Available We consider a finite-buffer single server queueing system with queue-length dependent vacations where arrivals occur according to a batch Markovian arrival process (BMAP. The service discipline is P-limited service, also called E-limited with limit variation (ELV where the server serves until either the system is emptied or a randomly chosen limit of L customers has been served. Depending on the number of customers present in the system, the server will monitor his vacation times. Queue-length distributions at various epochs such as before, arrival, arbitrary and after, departure have been obtained. Several other service disciplines like Bernoulli scheduling, nonexhaustive service, and E-limited service can be treated as special cases of the P-limited service. Finally, the total expected cost function per unit time is considered to determine locally optimal values N* of N or a maximum limit L^* of L^ as the number of customers served during a service period at a minimum cost.

  16. Effects of Surface Dipole Lengths on Evaporation of Tiny Water Aggregation

    International Nuclear Information System (INIS)

    Wang Shen; Wan Rongzheng; Fang Haiping; Tu Yusong

    2013-01-01

    Using molecular dynamics simulation, we compared evaporation behavior of a tiny amount of water molecules adsorbed on solid surfaces with different dipole lengths, including surface dipole lengths of 1 fold, 2 folds, 4 folds, 6 folds and 8 folds of 0.14 nm and different charges from 0.1e to 0.9e. Surfaces with short dipole lengths (1-fold system) can always maintain hydrophobic character and the evaporation speeds are not influenced, whether the surface charges are enhanced or weakened; but when surface dipole lengths get to 8 folds, surfaces become more hydrophilic as the surface charge increases, and the evaporation speeds increase gradually and monotonically. By tuning dipole lengths from 1-fold to 8-fold systems, we confirmed non-monotonic variation of the evaporation flux (first increases, then decreases) in 4 fold system with charges (0.1e–0.7e), reported in our previous paper [S. Wang, et al., J. Phys. Chem. B 116 (2012) 13863], and also show the process from the enhancement of this unexpected non-monotonic variation to its vanishment with surface dipole lengths increasing. Herein, we demonstrated two key factors to influence the evaporation flux of a tiny amount of water molecules adsorbed on solid surfaces: the exposed surficial area of water aggregation from where the water molecules can evaporate directly and the attraction potential from the substrate hindering the evaporation. In addition, more interestingly, we showed extra steric effect of surface dipoles on further increase of evaporation flux for 2-folds, 4-folds, 6-folds and 8-folds systems with charges around larger than 0.7e. (The steric effect is first reported by parts of our authors [C. Wang, et al., Sci. Rep. 2 (2012) 358]). This study presents a complete physical picture of the influence of surface dipole lengths on the evaporation behavior of the adsorbed tiny amount of water. (condensed matter: structural, mechanical, and thermal properties)

  17. Emerging and Submerging Shorelines: Impacts of Physical Change on Bioband Length

    Science.gov (United States)

    Kruger, L. E.; Johnson, A. C.; Gregovich, D.; Buma, B.; Noel, J.

    2017-12-01

    We approximated shifts in coastal benthic species for shoreline length units undergoing both sea level rise and relative sea level lowering (often post-glacial, termed isostatic rebound) where subsistence-based, southeast Alaska Natives reside. From six community centers, we examined 30 km radii shoreline reaches by merging relevant portions of the NOAA ShoreZone database with near shore bathymetry and measures of mean global sea level rise with local global positioning system information (GIS) of tectonic shift and isostatic rebound. For our analysis, we estimated change for 9,868 assessed shoreline length units having uniform substrate and biologic type over a 100-yr time span (2008-2108) using geometric analysis of shoreline attributes. For each shoreline length unit we assessed relationships among substrate, slope, exposure, and presence of five benthic species including eel grass (Zostera marina), blue mussel (Mytilus edulis), butter clams (Saxidomus gigantean), bull kelp (Nereocytis leutkeana), and foliose red algae including ribbon kelp (Palmaria sp.). Our research indicates that both emergence, up to 1.8 m, and submergence, up 0.2 m, of the land will result in disportionately larger shoreline length segment alterations for habitats in protected low-slope gradient bays and estuaries (dominated by eelgrass and butter clam habitats) with less change for rocky steep-gradient exposed penninsulas (red algae and canopy kelp). This trend, holding true regardless of isostatic rebound, tectonic shift or sea level rise rate, highlights the importance of initial geomorphology-based assessments serving to improve bio-physical, chemical, and socially-related coastal research. Where shorelines are emerging 30% decreases in estuary lengths are predicted, but where shorelines are submerging up to 3% increases in estuaries are expected. Our research results are consistent with anthropology studies assessing past coastal change. Coastal change, influencing subsistance foods

  18. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    DEFF Research Database (Denmark)

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty

    2011-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original...

  19. The Effect of CFRP Length on the Failure Mode of Strengthened Concrete Beams

    Directory of Open Access Journals (Sweden)

    Jun Ding

    2014-06-01

    Full Text Available This paper reports the effects of carbon fiber-reinforced polymer (CFRP length on the failure process, pattern and crack propagation for a strengthened concrete beam with an initial notch. The experiments measuring load-bearing capacity for concrete beams with various CFRP lengths have been performed, wherein the crack opening displacements (COD at the initial notch are also measured. The application of CFRP can significantly improve the load-bearing capacity, and the failure modes seem different with various CFRP lengths. The stress profiles in the concrete material around the crack tip, at the end of CFRP and at the interface between the concrete and CFRP are then calculated using the finite element method. The experiment measurements are validated by theoretical derivation and also support the finite element analysis. The results show that CFRP can significantly increase the ultimate load of the beam, while such an increase stops as the length reaches 0.15 m. It is also concluded that the CFRP length can influence the stress distribution at three critical stress regions for strengthened concrete beams. However, the optimum CFRP lengths vary with different critical stress regions. For the region around the crack tip, it is 0.15 m; for the region at the interface it is 0.25 m, and for the region at the end of CFRP, it is 0.30 m. In conclusion, the optimum CFRP length in this work is 0.30 m, at which CFRP strengthening is fully functioning, which thus provides a good reference for the retrofitting of buildings.

  20. In Vitro Comparative Study of the Working Length Determination with Radiovisiography and Conventional Radiography in Dilacerated Canals

    Directory of Open Access Journals (Sweden)

    Ali Bagherpour

    2015-06-01

    Full Text Available Introduction: The aim of this study was to compare digital and conventional radiography in determining the working length of dilacerated canals.Methods: Thirty nine human extracted single-rooted teeth with root curvature more than 35 degrees were included in this study. After access preparation, a file was inserted into the canal and advanced until the file tip was visualized at the foramen. With measurement of the file length using a millimeter ruler, true canal length was determined for each canal. Then, teeth were mounted in acrylic blocks and canal length was estimated by using on-screen digital radiography with both 3- and 6-clicks measurement and from conventional radiography by conforming a preserved file on the image of the root canal.Results: There were no significant differences in measurement accuracy between the true canal length and conventional radiographic length, but there were significant difference between both digital radiographic techniques with true canal length. There was no significant correlation between root curvature and canal length estimation error of studied methods.Conclusion: In dilacerated canals, the accuracy of determination of working length by using conventional radiography is higher than digital radiography