WorldWideScience

Sample records for left-atrial ball thrombus

  1. Left atrial thrombus following bilobectomy: a case report

    Directory of Open Access Journals (Sweden)

    Kaya Ugur

    2010-02-01

    Full Text Available Abstract Introduction Left atrial free floating ball thrombus is a relatively rare event, especially without mitral valve disease. Case presentation A 61-year-old Turkish man was admitted to our hospital with a thrombus mass in his left atrium. Five months earlier, he had undergone right bilobectomy and superior bronchoplasty due to squamous cell carcinoma in the lung. The patient had no evidence of cardiac disease except atrial fibrillation and there were no defined embolizations. The thrombus mass was surgically removed. The patient was discharged from hospital on the sixth postoperative day. Conclusion Surgery with cardiopulmonary bypass is a safe method for treatment. The patient should be medicated with warfarin, especially in the presence of atrial fibrillation.

  2. Late thrombosis of a mitral bioprosthetic valve with associated massive left atrial thrombus

    Directory of Open Access Journals (Sweden)

    Preetham R Muskula

    2017-04-01

    Full Text Available An 84-year-old man presented 5 years after bioprosthetic mitral valve replacement with three months of worsening dyspnea on exertion. A new mitral stenosis murmur was noted on physical examination, and an electrocardiogram revealed newly recognized atrial fibrillation. Severe mitral stenosis (mean gradient = 13 mmHg was confirmed by transthoracic echocardiography. Transesophageal echocardiography revealed markedly thickened mitral bioprosthetic leaflets with limited mobility, and a massive left atrial thrombus (>4 cm in diameter (Fig. 1A, B, C, D and Videos 1, 2, 3 and 4. Intravenous heparin was initiated, and 5 days later, he was taken to the operating room for planned redo mitral valve replacement and left atrial thrombus extraction. Intraoperative transesophageal echocardiography revealed near-complete resolution of the bioprosthetic leaflet thickening, and a mean mitral gradient of only 3 mmHg (Fig. 2A, B, C and Videos 5, 6 and 7. The patient underwent resection of the massive left atrial thrombus (Fig. 2D but did not require redo mitral valve replacement. He was initiated on heparin (and transitioned to warfarin early in the post-operative period, with complete resolution of dyspnea on exertion at 3-month follow-up. Bioprosthetic valve thrombosis is increasingly recognized as a cause of early prosthetic valve dysfunction (1, 2. This case illustrates that bioprosthetic valve thrombosis may occur years after valve replacement; therefore, any deterioration in a patient’s clinical status (new-onset dyspnea, heart failure or atrial fibrillation warrants a thorough evaluation of the bioprosthetic valve with transesophageal echocardiography. In this case, initiation of anticoagulation obviated the need for redo mitral valve replacement.

  3. Early Heparin Administration Reduces Risk for Left Atrial Thrombus Formation during Atrial Fibrillation Ablation Procedures

    Directory of Open Access Journals (Sweden)

    Stefan Asbach

    2011-01-01

    Full Text Available Objective. Despite the use of anticoagulation during left atrial (LA ablation procedures, ischemic cerebrovascular accidents (CVAs are recognized as a serious complication. Heparin is usually given after safe transseptal access has been obtained, resulting in a short unprotected dwell time of catheters within the LA, which may account for CVAs. We investigated the frequency of CVAs and LA thrombus formation as detected by intracardiac ultrasound (ICE depending on the timing of heparin administration. Methods and Results. Sixty LA ablation procedures with the use of ICE were performed in 55 patients. Patients were grouped by heparin administration after (Group I, =13 and before (Group II, =47 transseptal access. Group I patients were younger (56.6±13.7 versus 65.9±9.9 years, =.01; other clinical and echocardiographic characteristics did not differ between groups. Early thrombus formation was observed in 2 (15.4% of group I patients as compared to 0% of group II patients (=.04. One CVA (2.1% occurred in one group II patient without prior thrombus detection, and none occurred in group I patients (=ns. Conclusion. Early administration of heparin reduces the risk of early intracardiac thrombus formation during LA ablation procedures. This did not result in reduced rate of CVAs.

  4. Left atrial appendage myxofibrosarcoma: A rare masquerader of myxoma and thrombus-"all that glitters is not gold".

    Science.gov (United States)

    Khan, Muhammad Shoaib; Reddy, Sahadev; Lombardi, Richard; Isabel, Pitti; Mcgregor, Walter E; Tang, Bang; Gabriel, George; Biederman, Robert W

    2018-02-01

    Left atrial appendage mass can occasionally pose a serious challenge to physicians to identify the nature of the mass with the aid of imaging techniques. We present a case of 67-year-old man, who was evaluated for suspected left atria myxoma. Transesophageal echocardiography revealed a heterogeneous density originating from left atrial appendage, thought to be most consistent with a myxoma. Cardiac magnetic resonance imaging, uncharacteristically, gave an equivocal picture, suggesting the mass to be a myxoma on initial imaging and a thrombus with evidence of liquefaction necrosis following postcontrast enhancement. Surprisingly, histopathology of the mass following its surgical excision yielded a rare diagnosis of myxofibrosarcoma. © 2017, Wiley Periodicals, Inc.

  5. Effect of mitral regurgitation on cerebrovascular accidents in patients with atrial fibrillation and left atrial thrombus.

    Science.gov (United States)

    Nair, Chandra K; Aronow, Wilbert S; Shen, Xuedong; Anand, Kishlay; Holmberg, Mark J; Esterbrooks, Dennis J

    2009-11-01

    The effect of mitral regurgitation (MR) on the incidence of new cerebrovascular accidents (CVA) and mortality in patients with atrial fibrillation (AF) and left atrial thrombus (LAT) is unknown. To investigate the effect of MR in patients with AF and LAT on new CVA and mortality. Eighty nine consecutive patients, mean age 71 years, with AF and LAT documented by transesophageal echocardiography were investigated to determine the prevalence and severity of MR and the association of the severity of MR with new cerebrovascular accidents (CVA) and mortality at 34-mo follow-up. Of 89 patients, 1 + MR was present in 23 patients (26%), 2 + MR in 44 patients (50%), 3 + MR in 17 patients (19%), and 4 + MR in 3 patients (4%). Mean follow-up was 34 +/- 28 mo. The Cox proportional hazards model showed that the severity of increased MR did not significantly increase new CVA or mortality at 34-mo follow-up. The only variable predictive of mortality was left ventricular ejection fraction (LVEF), and with every unit increase in LVEF, the risk decreased by 3%. MR occurred in 87 of 89 patients (98%) with AF and LAT. There was no association between the severity of MR and the incidence of CVA or mortality.

  6. Incidence of thromboembolism following detection by trans-oesophageal echocardiography of left atrial thrombus

    Directory of Open Access Journals (Sweden)

    Ciara Mahon

    2015-09-01

    Conclusion: This is the only study to date that has looked at the incidence of ischemic stroke following a confirmed LAA thrombus, LA thrombus or pre-thrombus state. This single centre study found low stroke rates over a six month follow-up period in patients with a confirmed LAA thrombus, LA thrombus or pre-thrombus state and optimization of OAC. Larger studies would be required to confirm these findings.

  7. Left atrial appendage thrombus with resulting stroke post-RF ablation for atrial fibrillation in a patient on dabigatran.

    LENUS (Irish Health Repository)

    Lobo, R

    2015-11-01

    Dabigatran etexilate is licensed for use in prevention of deep venous thromboembolism and in prevention of stroke and systemic embolism in nonvalvular atrial fibrillation (AF). It has also been used in patients for other indications as a substitute for warfarin therapy because it requires no monitoring; one group being patients undergoing radiofrequency (RF), ablation for AF, although there have been no consensus guidelines with regards to dosage and timing of dose. We report the case of a patient with documentary evidence of left atrial appendage (LAA) thrombus formation and neurological sequelae post-RF ablation despite being on dabigatran. This case highlights the concern that periprocedural dabigatran may not provide adequate protection from development of LAA thrombus and that a standardised protocol will need to be developed and undergo large multicentre trials before dabigatran can be safely used for patients undergoing RF-ablation.

  8. Left atrial appendage occlusion

    Directory of Open Access Journals (Sweden)

    Ahmad Mirdamadi

    2013-01-01

    Full Text Available Left atrial appendage (LAA occlusion is a treatment strategy to prevent blood clot formation in atrial appendage. Although, LAA occlusion usually was done by catheter-based techniques, especially percutaneous trans-luminal mitral commissurotomy (PTMC, it can be done during closed and open mitral valve commissurotomy (CMVC, OMVC and mitral valve replacement (MVR too. Nowadays, PTMC is performed as an optimal management of severe mitral stenosis (MS and many patients currently are treated by PTMC instead of previous surgical methods. One of the most important contraindications of PTMC is presence of clot in LAA. So, each patient who suffers of severe MS is evaluated by Trans-Esophageal Echocardiogram to rule out thrombus in LAA before PTMC. At open heart surgery, replacement of the mitral valve was performed for 49-year-old woman. Also, left atrial appendage occlusion was done during surgery. Immediately after surgery, echocardiography demonstrates an echo imitated the presence of a thrombus in left atrial appendage area, although there was not any evidence of thrombus in pre-pump TEE. We can conclude from this case report that when we suspect of thrombus of left atrial, we should obtain exact history of previous surgery of mitral valve to avoid misdiagnosis clotted LAA, instead of obliterated LAA. Consequently, it can prevent additional evaluations and treatments such as oral anticoagulation and exclusion or postponing surgeries including PTMC.

  9. Frequency of left atrial thrombus detected by transesophageal echocardiography in patients of tight mitral stenosis having negative trans-thoracic echocardiography at gulab devi cardiac complex

    International Nuclear Information System (INIS)

    Fayyaz, A.; Iqbal, M.W.

    2014-01-01

    Introduction: Patients with mitral stenosis (MS) having atrial fibrillation (AF) are more prone to develop left atrial (LA) thrombus. Systemic embolism, related to LA thrombus is a well-known risk of Percutaneous Mitral Balloon Valvotomy (PMBV) of the mitral valve. Therefore presence of LA thrombus is a contraindication to PMBV. Objective: Objective of this study was to detect the frequency of LA thrombus by transesophageal echocardiography (TEE) in patients of tight MS in whom transthoracic echocardiography (TTE) could not detect any LA thrombus. Patients and Methods: In this cross sectional study, we took 100 indoor patients with tight MS on non-probability consecutive sampling. Data was collected after meeting inclusion criteria. Patients were taken in this study after acquiring written informed consent. Symptoms were inquired from all patients and functional status was assessed by New York Heart Association class. Unstable patients were medically managed before the procedure. TEE was done on the same day before undergoing PMBV to look for clot in LA. Results: The mean age of the patients was 32.20 years and SD was 11.3 years. There were 36(36%) male patients and 64(64%) female patients. LA thrombus was present in 40% of patients on TEE out of which 19 were male patients (52.77%) and 21 were female patients (32.81%). Conclusion: Patients with mitral stenosis having AF are more prone to develop LA thrombus. In this study, the frequency of LA thrombus was 40% recorded, which is high. Due to the potential risk of embolization, it is strongly recommended to perform TEE in patients with normal TTE study before undergoing PMBV. The presence of a LA thrombus should be considered a contraindication to the PMBV of the mitral valve. (author)

  10. Higher levels of serum fibrin-monomer reflect hypercoagulable state and thrombus formation in the left atrial appendage in patients with acute ischemic stroke.

    Science.gov (United States)

    Okuyama, Hidenobu; Hirono, Osamu; Liu, Ling; Takeishi, Yasuchika; Kayama, Takamasa; Kubota, Isao

    2006-08-01

    It is sometimes difficult to make a diagnosis of cardioembolic stroke in the stroke care unit, because of the splashing and vanishing of the intracardiac source of the emboli on transesophageal echocardiography. Serum fibrin-monomer (FM) is a new marker for coagulation activity that is useful for identifying older individuals at increased risk of ischemic stroke. Two hundred and four patients with acute ischemic stroke were examined for serum coagulation and fibrinolytic activity on admission, and underwent transesophageal echocardiography within 7 days of onset. Serum levels of FM was significantly higher in patients with left atrial appendage (LAA) thrombus formation (n=24) than in those with no thrombus (88+/-52 vs 14+/-9 microg/ml, pvs 8+/-5 microg/ml, pstroke.

  11. Motion of left atrial appendage as a determinant of thrombus formation in patients with a low CHADS2 score receiving warfarin for persistent nonvalvular atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Ono Koji

    2012-12-01

    Full Text Available Abstract Background The aim of this study was to define the independent determinants of left atrial appendage (LAA thrombus among various echocardiographic parameters measured by Velocity Vector Imaging (VVI in patients with nonvalvular atrial fibrillation (AF receiving warfarin, particularly in patients with a low CHADS2 score. Methods LAA emptying fraction (EF and LAA peak longitudinal strain were measured by VVI using transesophageal echocardiography in 260 consecutive patients with nonvalvular persistent AF receiving warfarin. The patients were divided into two groups according to the presence (n=43 or absence (n=217 of LAA thrombus. Moreover, the patients within each group were further divided into subgroups according to a CHADS2 score ≤1. Results Multivariate logistic regression analysis showed that LAAEF was an independent determinant of LAA thrombus in the subgroup of 140 with a low CHADS2 score. Receiver operating characteristics curve analysis showed that an LAAEF of 21% was the optimal cutoff value for predicting LAA thrombus. Conclusions LAA thrombus formation depended on LAA contractility. AF patients with reduced LAA contractile fraction (LAAEF ≤21% require strong anticoagulant therapy to avoid thromboembolic events regardless of a low CHADS2 score (≤1.

  12. Detection of left atrial thrombus in patients with mitral stenosis and atrial fibrillation: retrospective comparison of two-phase computed tomography, transoesophageal echocardiography and surgical findings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Bo Hwa; Ko, Sung Min [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Radiology, Research Institute of Medical Science, Seoul (Korea, Republic of); Hwang, Hweung Kon [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Cardiology, Seoul (Korea, Republic of); Song, Meong Gun; Shin, Je Kyoun [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Thoracic surgery, Seoul (Korea, Republic of); Kang, Woon Seok; Kim, Tae-Yop [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Anesthesiology, Seoul (Korea, Republic of)

    2013-11-15

    This retrospective study aims to assess the accuracy of two-phase computed tomography (CT) and transoesophageal echocardiography (TEE) for the detection of left atrial (LA) thrombus in patients with mitral stenosis (MS) and atrial fibrillation (AF), by using intraoperative findings as the reference standard. Preoperative two-phase CT and intraoperative TEE were performed in 106 patients with MS and AF. The ratio (LAA/AA{sub L}) of Hounsfield units (HU) in the LA appendage (LAA) to the ascending aorta (AA) was calculated on the late-phase CT image. LA echodense masses on TEE and LA filling defects on two-phase CT were observed in 29 and 39 patients, respectively. Thirty-five LA thrombi were identified at surgery in 27 patients. Compared with the intraoperative findings, per-patient sensitivity, specificity, positive and negative predictive values of two-phase CT were 100 %, 85 %, 69 % and 100 %, and those by using TEE were 93 %, 95 %, 86 % and 97 % in detecting LAA thrombus. After adopting the cut-off value of 0.5 for the LAA/AA{sub L} HU ratio, the specificity and positive predictive value of two-phase CT were increased to 96 % and 90 %, respectively. Two-phase CT with a cut-off value of LAA/AA{sub L} HU ratio of 0.5 provides high performance for the detection of LAA thrombus. (orig.)

  13. Occult left atrial ball-like thrombus in a patient referred for surgical removal of suspected cerebellum tumor

    International Nuclear Information System (INIS)

    Możeńska, Olga; Kalińska, Irena; Brodowski, Karol; Walecki, Jerzy; Kosior, Dariusz A.

    2014-01-01

    Atrial fibrillation and related cardio-embolic cerebrovascular accidents are two well-defined major healthcare problems worldwide. It has been approximated that 2.2 million people in America and 4.5 million in European Union have paroxysmal or persistent atrial fibrillation. And atrial fibrillation itself is an independent long-term risk factor of stroke. We present a case of patient referred to our center for surgical removal of suspected cerebellum tumor, a case that had a rather unexpected ending. A 58-year-old male patient with a history of atrial fibrillation, congestive heart failure (NYHA II/III), stable coronary artery disease, diabetes type 2 and hyperlipidemia presented with vertigo, headaches, mainly during physical activity and increased tiredness. Performed computer tomography revealed two lesions in the cerebellum and in the left lateral chamber. The diagnosis of a proliferative disease of the cerebellum was established and patient was referred to the Neurosurgical Department. Fortunately, before the operation the echocardiography was performed, which revealed two lesions in left atrium. The decision of the Heart Team was to refer the patient for an open-heart surgery, in which two thrombi were removed. Neurosurgeons decided to withdraw from further surgery and proceed with head MRI and conservative treatment, deciding that the lesion in the cerebellum was most likely an ischemic area. Looking at the brain lesion should always be done from the whole patient’s perspective. And using mutlimodality imaging may lead to appropriate diagnosis, correct course of therapeutic action and unexpected ending of a rather non-extraordinary case

  14. Split-bolus single-phase cardiac multidetector computed tomography for reliable detection of left atrial thrombus. Comparison to transesophageal echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Staab, W.; Zwaka, P.A.; Sohns, J.M.; Schwarz, A.; Lotz, J. [University Medical Center Goettingen Univ. (Germany). Inst. for Diagnostic and Interventional Radiology; Sohns, C.; Vollmann, D.; Zabel, M.; Hasenfuss, G. [Goettingen Univ. (Germany). Dept. of Cardiology and Pneumology; Schneider, S. [Goettingen Univ. (Germany). Dept. of Medical Statistics

    2014-11-15

    Evaluation of a new cardiac MDCT protocol using a split-bolus contrast injection protocol and single MDCT scan for reliable diagnosis of LA/LAA thrombi in comparison to TEE, optimizing radiation exposure and use of contrast agent. A total of 182 consecutive patients with drug refractory AF scheduled for PVI (62.6% male, mean age: 64.1 ± 10.2 years) underwent routine diagnostic work including TEE and cardiac MDCT for the evaluation of LA/LAA anatomy and thrombus formation between November 2010 and March 2012. Contrast media injection was split into a pre-bolus of 30 ml and main bolus of 70 ml iodinated contrast agent separated by a short time delay. In this study, split-bolus cardiac MDCT identified 14 of 182 patients with filling defects of the LA/LAA. In all of these 14 patients, abnormalities were found in TEE. All 5 of the 14 patients with thrombus formation in cardiac MDCT were confirmed by TEE. MDCT was 100% accurate for thrombus, with strong but not perfect overall results for SEC equivalent on MDCT.

  15. Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Merih Cibis

    2017-12-01

    Full Text Available Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR enables blood flow assessment from the entire three-dimensional atrial volume throughout the cardiac cycle. We sought to investigate left atrial 4D blood flow patterns and hemostasis during left atrial stunning and after left atrial mechanical function was restored.Methods: 4D Flow and morphological CMR data as well as blood samples were collected in fourteen patients at two time-points: 2–3 h (Time-1 and 4 weeks (Time-2 following cardioversion. The volume of blood stasis and duration of blood stasis were calculated. In addition, hemostasis markers were analyzed.Results: From Time-1 to Time-2: Heart rate decreased (61 ± 7 vs. 56 ± 8 bpm, p = 0.01; Maximum change in left atrial volume increased (8 ± 4 vs. 22 ± 15%, p = 0.009; The duration of stasis (68 ± 11 vs. 57 ± 8%, p = 0.002 and the volume of stasis (14 ± 9 vs. 9 ± 7%, p = 0.04 decreased; Thrombin-antithrombin complex (TAT decreased (5.2 ± 3.3 vs. 3.3 ± 2.2 μg/L, p = 0.008. A significant correlation was found between TAT and the volume of stasis (r2 = 0.69, p < 0.001 at Time-1 and between TAT and the duration of stasis (r2 = 0.34, p = 0.04 at Time-2.Conclusion: In this longitudinal study, left atrial multidimensional blood flow was altered and blood stasis was elevated during left atrial stunning compared to the restored left atrial mechanical function. The coagulability of blood was also elevated during atrial stunning. The association between blood stasis and hypercoagulability proposes that assessment of left atrial 4D flow can add to the pathophysiological understanding of thrombus formation during atrial fibrillation

  16. Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation

    Science.gov (United States)

    Cibis, Merih; Lindahl, Tomas L.; Ebbers, Tino; Karlsson, Lars O.; Carlhäll, Carl-Johan

    2017-01-01

    Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR) enables blood flow assessment from the entire three-dimensional atrial volume throughout the cardiac cycle. We sought to investigate left atrial 4D blood flow patterns and hemostasis during left atrial stunning and after left atrial mechanical function was restored. Methods: 4D Flow and morphological CMR data as well as blood samples were collected in fourteen patients at two time-points: 2–3 h (Time-1) and 4 weeks (Time-2) following cardioversion. The volume of blood stasis and duration of blood stasis were calculated. In addition, hemostasis markers were analyzed. Results: From Time-1 to Time-2: Heart rate decreased (61 ± 7 vs. 56 ± 8 bpm, p = 0.01); Maximum change in left atrial volume increased (8 ± 4 vs. 22 ± 15%, p = 0.009); The duration of stasis (68 ± 11 vs. 57 ± 8%, p = 0.002) and the volume of stasis (14 ± 9 vs. 9 ± 7%, p = 0.04) decreased; Thrombin-antithrombin complex (TAT) decreased (5.2 ± 3.3 vs. 3.3 ± 2.2 μg/L, p = 0.008). A significant correlation was found between TAT and the volume of stasis (r2 = 0.69, p < 0.001) at Time-1 and between TAT and the duration of stasis (r2 = 0.34, p = 0.04) at Time-2. Conclusion: In this longitudinal study, left atrial multidimensional blood flow was altered and blood stasis was elevated during left atrial stunning compared to the restored left atrial mechanical function. The coagulability of blood was also elevated during atrial stunning. The association between blood stasis and hypercoagulability proposes that assessment of left atrial 4D flow can add to the pathophysiological understanding of thrombus formation during atrial fibrillation related

  17. Effect of left ventricular diastolic dysfunction on left atrial appendage function and thrombotic potential in nonvalvular atrial fibrillation.

    Science.gov (United States)

    Demirçelik, Muhammed Bora; Çetin, Mustafa; Çiçekcioğlu, Hülya; Uçar, Özgül; Duran, Mustafa

    2014-05-01

    We aimed to investigate effects of left ventricular diastolic dysfunction on left atrial appendage functions, spontaneous echo contrast and thrombus formation in patients with nonvalvular atrial fibrillation. In 58 patients with chronic nonvalvular atrial fibrilation and preserved left ventricular systolic function, left atrial appendage functions, left atrial spontaneous echo contrast grading and left ventricular diastolic functions were evaluated using transthoracic and transoesophageal echocardiogram. Patients divided in two groups: Group D (n=30): Patients with diastolic dysfunction, Group N (n=28): Patients without diastolic dysfunction. Categorical variables in two groups were evaluated with Pearson's chi-square or Fisher's exact test. The significance of the lineer correlation between the degree of spontaneous echo contrast (SEC) and clinical measurements was evaluated with Spearman's correlation analysis. Peak pulmonary vein D velocity of the Group D was significantly higher than the Group N (p=0.006). However, left atrial appendage emptying velocity, left atrial appendage lateral wall velocity, peak pulmonary vein S, pulmonary vein S/D ratio were found to be significantly lower in Group D (p=0.028, patrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities respectively (r=-0.438, r=-0.328, r=-0.233, r=-0.447). Left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities were significantly lower in SEC 2-3-4 than SEC 1 (p=0.003, p=0.029, patrial fibrillation and preserved left ventricular ejection fraction, left atrial appendage functions are decreased in patients with left ventricular diastolic dysfunction. Left ventricular diastolic dysfunction may constitute a potential risk for formation of thrombus and stroke.

  18. Combined percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation for rheumatic mitral stenosis and atrial fibrillation

    International Nuclear Information System (INIS)

    Murdoch, Dale; McAulay, Laura; Walters, Darren L.

    2014-01-01

    Rheumatic heart disease is a common cause of cardiovascular morbidity and mortality worldwide, mostly in developing countries. Mitral stenosis and atrial fibrillation often coexist, related to both structural and inflammatory changes of the mitral valve and left atrium. Both predispose to left atrial thrombus formation, commonly involving the left atrial appendage. Thromboembolism can occur, with devastating consequences. We report the case of a 62 year old woman with rheumatic heart disease resulting in mitral stenosis and atrial fibrillation. Previous treatment with warfarin resulted in life-threatening gastrointestinal bleeding and she refused further anticoagulant therapy. A combined procedure was performed, including percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation with the Atritech® Watchman® device. No thromboembolic or bleeding complications were encountered at one year follow-up. Long-term follow-up in a cohort of patients will be required to evaluate the safety and efficacy of this strategy

  19. Combined percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation for rheumatic mitral stenosis and atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Murdoch, Dale, E-mail: dale_murdoch@health.qld.gov.au [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia); McAulay, Laura [The Prince Charles Hospital, Brisbane (Australia); Walters, Darren L. [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia)

    2014-11-15

    Rheumatic heart disease is a common cause of cardiovascular morbidity and mortality worldwide, mostly in developing countries. Mitral stenosis and atrial fibrillation often coexist, related to both structural and inflammatory changes of the mitral valve and left atrium. Both predispose to left atrial thrombus formation, commonly involving the left atrial appendage. Thromboembolism can occur, with devastating consequences. We report the case of a 62 year old woman with rheumatic heart disease resulting in mitral stenosis and atrial fibrillation. Previous treatment with warfarin resulted in life-threatening gastrointestinal bleeding and she refused further anticoagulant therapy. A combined procedure was performed, including percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation with the Atritech® Watchman® device. No thromboembolic or bleeding complications were encountered at one year follow-up. Long-term follow-up in a cohort of patients will be required to evaluate the safety and efficacy of this strategy.

  20. An unexpected complication of acute pancreatitis: Intra-cardiac thrombus.

    Science.gov (United States)

    Keskin, Muhammed; Gümüşdağ, Ayça; Börklü, Edibe Betül; Dayı, Şennur Ünal; Avcı, İlhan İlker; Güvenç, Tolga Sinan; Güngör, Barış; Karabay, Can Yücel; Kozan, Ömer

    2017-05-01

    Left atrial thrombus after acute pancreatitis (AP) is a rare clinical statement. Because of induction of systemic prothrombotic process by AP; some patients with underlying risk factors may develop an intra-cardiac thrombus. We present a 53years-old-woman with moderate mitral stenosis and atrial fibrillation. However the patient was under warfarin treatment, she developed a big left atrial big thrombus which was originated from left atrial appendage after she was suffered from AP. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Echocardiographic study of left atrial myxoma

    Directory of Open Access Journals (Sweden)

    Dalal J

    1979-01-01

    Full Text Available Four cases of left atrial myxoma were diagnosed pre-operatively by echocardiography. All cases showed characteristic echocardio-graphic features of variegated shadows behind the mitral valve in diastole and within the left atrium in systole. In two cases the my-xomas were surgically removed and confirmed on histology. In one case the post-operative echocardiogram showed complete dis-appearance of the abnormal shadows. Echocardiography is the most reliable method today for the diagnosis of a myxoma.

  2. Left Atrial Decompression by Percutaneous Left Atrial Venting Cannula Insertion during Venoarterial Extracorporeal Membrane Oxygenation Support

    Directory of Open Access Journals (Sweden)

    Ha Eun Kim

    2016-06-01

    Full Text Available Patients with venoarterial extracorporeal membrane oxygenation (ECMO frequently suffer from pulmonary edema due to left ventricular dysfunction that accompanies left heart dilatation, which is caused by left atrial hypertension. The problem can be resolved by left atrium (LA decompression. We performed a successful percutaneous LA decompression with an atrial septostomy and placement of an LA venting cannula in a 38-month-old child treated with venoarterial ECMO for acute myocarditis.

  3. Assessment of left atrial volume and function

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Lønborg, Jacob; Fuchs, Andreas

    2012-01-01

    dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty......-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir...... between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P ...

  4. Occlusion of left atrial appendage in patients with atrial fibrillation

    Directory of Open Access Journals (Sweden)

    О. Н. Ганеева

    2015-10-01

    Full Text Available The article reviews a new method of prophylaxis of thromboembolitic complications, specifically occlusion of left atrial appendage, in patients with atrial fibrillation. Indications and contraindications for the procedure, as well as a step-by-step process of the intervention itself are described. Special emphasis is placed on the up-to-date evidence and the review of clinical trials.

  5. The left atrial catheter: its uses and complications.

    Science.gov (United States)

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  6. Transient left atrial dysfunction is a feature of Takotsubo syndrome

    DEFF Research Database (Denmark)

    Stiermaier, Thomas; Graf, Tobias; Möller, Christian

    2017-01-01

    BACKGROUND: Takotsubo syndrome (TTS) is characterized by a transient left and/or right ventricular dysfunction as a consequence of a distinctive pattern of regional wall motion abnormalities. However, a systematic evaluation of the left atrial (LA) function in patients with TTS is lacking. The ai...

  7. Percutaneous left atrial appendage closure for stroke prevention

    DEFF Research Database (Denmark)

    De Backer, Ole; Loupis, Anastasia M; Ihlemann, Nikolaj

    2014-01-01

    INTRODUCTION: In atrial fibrillation (AF) patients with an increased stroke risk, oral anticoagulation (OAC) is the standard treatment for stroke prevention. However, this therapy carries a high risk of major bleeding. Percutaneous closure of the left atrial appendage (LAA) is suggested as an alt...

  8. Speckle tracking analysis: a new tool for left atrial function analysis in systemic hypertension: an overview.

    Science.gov (United States)

    Cameli, Matteo; Ciccone, Marco M; Maiello, Maria; Modesti, Pietro A; Muiesan, Maria L; Scicchitano, Pietro; Novo, Salvatore; Palmiero, Pasquale; Saba, Pier S; Pedrinelli, Roberto

    2016-05-01

    Speckle tracking echocardiography (STE) is an imaging technique applied to the analysis of left atrial function. STE provides a non-Doppler, angle-independent and objective quantification of left atrial myocardial deformation. Data regarding feasibility, accuracy and clinical applications of left atrial strain are rapidly gathering. This review describes the fundamental concepts of left atrial STE, illustrates its pathophysiological background and discusses its emerging role in systemic arterial hypertension.

  9. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Hamada, Seiki [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Takamiya, Makoto [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Kuribayashi, Sachio [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Naito, Hiroaki [Biomedical Research Center, Osaka Univ. School of Medicine, Suita (Japan)

    1994-10-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  10. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    International Nuclear Information System (INIS)

    Nakanishi, Tadashi; Hamada, Seiki; Takamiya, Makoto; Kuribayashi, Sachio; Naito, Hiroaki

    1994-01-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  11. Computational Fluid Dynamic Analysis of the Left Atrial Appendage to Predict Thrombosis Risk

    Directory of Open Access Journals (Sweden)

    Giorgia Maria Bosi

    2018-04-01

    Full Text Available During Atrial Fibrillation (AF more than 90% of the left atrial thrombi responsible for thromboembolic events originate in the left atrial appendage (LAA, a complex small sac protruding from the left atrium (LA. Current available treatments to prevent thromboembolic events are oral anticoagulation, surgical LAA exclusion, or percutaneous LAA occlusion. However, the mechanism behind thrombus formation in the LAA is poorly understood. The aim of this work is to analyse the hemodynamic behaviour in four typical LAA morphologies - “Chicken wing”, “Cactus”, “Windsock” and “Cauliflower” - to identify potential relationships between the different shapes and the risk of thrombotic events. Computerised tomography (CT images from four patients with no LA pathology were segmented to derive the 3D anatomical shape of LAA and LA. Computational Fluid Dynamic (CFD analyses based on the patient-specific anatomies were carried out imposing both healthy and AF flow conditions. Velocity and shear strain rate (SSR were analysed for all cases. Residence time in the different LAA regions was estimated with a virtual contrast agent washing out. CFD results indicate that both velocity and SSR decrease along the LAA, from the ostium to the tip, at each instant in the cardiac cycle, thus making the LAA tip more prone to fluid stagnation, and therefore to thrombus formation. Velocity and SSR also decrease from normal to AF conditions. After four cardiac cycles, the lowest washout of contrast agent was observed for the Cauliflower morphology (3.27% of residual contrast in AF, and the highest for the Windsock (0.56% of residual contrast in AF. This suggests that the former is expected to be associated with a higher risk of thrombosis, in agreement with clinical reports in the literature. The presented computational models highlight the major role played by the LAA morphology on the hemodynamics, both in normal and AF conditions, revealing the potential

  12. Clinical study on left atrial thrombi. Comparative study between echocardiography and CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, E; Asano, H; Kurasawa, T; Mitsumoto, K; Yamane, Y [Tokyo Kosei-Nenkin Hospital (Japan)

    1981-09-01

    We studied left atrial thrombi (LAT) by both echocardiography and computed tomography (CT) and compared the features of the 2 methods. A total of 15 patients with mitral stenosis complicated by atrial fibrillation were selected as the subjects. LAT were noted on the M-mode echocardiograms in 2 patients including a questionably positive one, on the two-dimensional echocardiograms in 5, and on the CT scans in 6 of 15. The history of thromboembolism was rather frequent and was found in 7 of 15 patients. However, LAT was found in only 3 of these on the CT scans. A shaggy or fuzzy pattern on the M-mode echocardiogram cannot be regarded as representing thrombi, while a laminar pattern undoubtedly represented thrombi. Two-dimensional echocardiography has considerably contributed to the improved detection rate of LAT. For the characteristic properties of ultrasound beams, however, it was impossible to investigate the entire left atrium. The detection of the thrombi in the appendage was especially difficult. However, computed tomography, permitting transverse cross-sectional tomography, was capable of sectioning the heart even in the presence of air and bones. The measurement of CT values was suggestive of the properties of the substance or substances involved, and also allowed the presumption as to whether the thrombus has been fibrosed. Furthermore, it was possible to estimate more accurately as well as 3-dimensionally the location, shape and dimensions of the thrombi by the reconstruction of the heart according to the CT values. It was concluded that echocardiography and computed tomography are the mutual aid to further improvement in the detection rate of left atrial thrombi.

  13. 111In-labeled platelet scintigraphy and two-dimensional echocardiography for detection of left atrial appendage thrombi. Studies in a new canine model

    International Nuclear Information System (INIS)

    Vandenberg, B.F.; Seabold, J.E.; Conrad, G.R.; Kieso, R.; Johnson, J.; Fox-Eastham, K.; Ponto, J.; Bruch, P.; Kerber, R.E.

    1988-01-01

    111In-labeled platelet scintigraphy and two-dimensional echocardiography were performed in 40 dogs to determine the ability of the two techniques to detect left atrial appendage thrombi. Thrombi were induced in 33 dogs that were classified into two groups, acute or chronic, according to the time of labeled-platelet injection after thrombus induction. In the acute group (17 dogs), platelets were injected 24 hours after thrombus induction. In the chronic group (16 dogs), platelets were injected 4-8 days after thrombus induction. Sham thoracotomies were performed on seven additional control dogs who did not receive thrombin injections. Analog and blood pool-corrected 111In-labeled platelet scintigraphy images were obtained 4-72 hours later. Closed-chest two-dimensional echocardiography was performed before thoracotomy and repeated at the time of scintigraphy. The location and size of each thrombus were verified at autopsy. Two-dimensional echocardiography detected three of 17 acute (mean volume, 1.2 +/- 1.0 cc) and three of 10 chronic (mean volume, 0.4 +/- 0.3 cc; p less than 0.025) left atrial appendage thrombi. 111In-labeled platelet scintigraphy detected all 17 acute thrombi but only two of 10 chronic thrombi. The measured radioactivity levels of the excised thrombi were 1,949 +/- 1,665 cpm/clot/dose in group 1 and 228 +/- 213 cpm/clot/dose in group 2 (p less than 0.005). In this model, 111In-labeled platelet scintigraphy was able to detect acute left atrial appendage thrombi that could not be identified by two-dimensional echocardiography. Both techniques showed poor sensitivity for detection of chronic thrombi. The decline in sensitivity of 111In-labeled platelet scintigraphy for detection of older thrombi is probably due to diminished labeled-platelet incorporation

  14. Hemostasis of Left Atrial Appendage Bleed With Lariat Device

    Directory of Open Access Journals (Sweden)

    Amena Hussain, MD

    2014-09-01

    Full Text Available New devices designed for minimally invasive closure of the left atrial appendage (LAA may be a viable alternative for patients in whom anticoagulation is considered high risk. The Lariat (Sentreheart, Redwood City, CA, which is currently FDA-approved for percutaneous closure of tissue, requires both trans-septal puncture and epicardial access. However it requires no anticoagulation after the procedure. Here we describe a case of effusion and tamponade during a Lariat procedure with successful completion of the case and resolution of the effusion.

  15. Management of left atrial myxomas at civil hospital, Karachi

    International Nuclear Information System (INIS)

    Iqbal, M.I.; Khan, A.B.; Aftab, S.; Mahmood, S.A.

    2008-01-01

    To study the outcome of the management of left atrial myxoma. The diagnosis was made according to clinical presentation and echocardiographic examinations. Tumour excised under cardiopulmonary bypass using aortic and bicaval cannulation and moderate hypothermia. Variables noted were surgical approach, pathological findings and complications after surgery. Of the 12 cases, six were male and six female, with a mean age of 33.67+-6.05 years. Fatigue and fever were the most common general symptoms, and dyspnoea the most common cardiologic symptom. The pedunculated atrial tumours were excised by trans-septal approach; tumour size ranged between 1.5x1x0.7 cms to 9x8x6 cms and weight 3-140 gms. Histopathology confirmed the tumours as atrial myxomas. One patient died of cerebrovascular accident on the 3rd postoperative day. So far, there has been no recurrence of the tumours. Surgical treatment with wide excision of left atrial myxomas by trans-septal approach is a suitable approach with negligible chances of recurrence. (author)

  16. Electron-beam computed tomography findings of left atrial appendage in patients with cardiogenic cerebral embolism

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Makiko; Takahashi, Satoshi; Yonezawa, Hisashi [Iwate Medical Univ., Morioka (Japan). School of Medicine

    2002-04-01

    We studied electron-beam computed tomography (EBCT) findings in the left atrial appendage of 72 patients with cerebral embolism [27 in the acute phase (<48 hours) and 45 in the chronic phase], 9 cases with nonvalvular atrial fibrillation (NVAF) but without stroke, and 13 controls. EBCT was performed in the early (during injection of contrast medium), late-1 (5 min after injection), and-2 (10 min after injection) phases. In the acute phase patients, 41% showed filling defect (FD) in the early phase alone (FDE), 15% showed FD until late phase-1 (FDL-1), and 15% showed FD until late phase-2 (FDL-2). The chronic phase patients showed FDE in 33% of cases, FDL-1 in 8% and FDL-2 11%. Only FDE was observed in 44% in NVAF cases without stroke. No FDs were observed in controls. Flow velocity in the appendage measured by transesophageal echocardiography was 23{+-}10 cm/sec in 21 FDE cases, 14{+-}3 cm/sec in 3 FDL-1 cases, 29{+-}23 cm/sec in 4 FDL-2 cases, significantly lower in comparison with 58{+-}25 cm/s in the 23 cases with no FD. FDL-1 and -2 suggested severe stasis or presence of thrombus in the appendage, which indicated high risk of embolism slower the movement of MES through the sample volume. (author)

  17. Left atrial appendage thrombosis during therapy with rivaroxaban in elective cardioversion for permanent atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Walter Serra

    2015-09-01

    Full Text Available Electric external cardioversion (EEC for permanent atrial fibrillation (AF carries a risk of thromboembolic events (TE. The use of transesophageal echocardiography (TEE to guide the management of atrial fibrillation may be considered a clinically effective alternative strategy to conventional therapy for patients in whom elective cardioversion is planned. Therapeutic anticoagulation with novel oral anticoagulants (NOAC is recommended for 3 to 4 weeks before and an anticoagulation life-long therapy is recommended after EEC to reduce TE, in patients with high CHA2DS2-VASc score; however, only few data are currently available about safety of shortterm anticoagulation with NOAC in the setting of EEC. Patients with increased risk of thromboembolism have not been adequately studied and the monitoring of anticoagulant effects can also have important benefits in case of drug interactions. We report a case of a 68-year old man with AF from September 2014. Moderate depression of global left ventricular systolic function was detected by echocardiographic exam. On the basis of a high thromboembolic risk, an anticoagulant therapy with rivaroxaban, at the dose of 20 mg/day, was started. TEE showed a thrombus in the left atrial appendage. This case demonstrates the utility of performing TEE prior than EEC in patients with hypokinetic cardiomyopathy other than AF in therapy with NOAC. We underline the presence of significant pharmacodynamic interference of rivaroxaban with other drugs such as oxcarbazepine.

  18. Electron-beam computed tomography findings of left atrial appendage in patients with cardiogenic cerebral embolism

    International Nuclear Information System (INIS)

    Okamoto, Makiko; Takahashi, Satoshi; Yonezawa, Hisashi

    2002-01-01

    We studied electron-beam computed tomography (EBCT) findings in the left atrial appendage of 72 patients with cerebral embolism [27 in the acute phase (<48 hours) and 45 in the chronic phase], 9 cases with nonvalvular atrial fibrillation (NVAF) but without stroke, and 13 controls. EBCT was performed in the early (during injection of contrast medium), late-1 (5 min after injection), and-2 (10 min after injection) phases. In the acute phase patients, 41% showed filling defect (FD) in the early phase alone (FDE), 15% showed FD until late phase-1 (FDL-1), and 15% showed FD until late phase-2 (FDL-2). The chronic phase patients showed FDE in 33% of cases, FDL-1 in 8% and FDL-2 11%. Only FDE was observed in 44% in NVAF cases without stroke. No FDs were observed in controls. Flow velocity in the appendage measured by transesophageal echocardiography was 23±10 cm/sec in 21 FDE cases, 14±3 cm/sec in 3 FDL-1 cases, 29±23 cm/sec in 4 FDL-2 cases, significantly lower in comparison with 58±25 cm/s in the 23 cases with no FD. FDL-1 and -2 suggested severe stasis or presence of thrombus in the appendage, which indicated high risk of embolism slower the movement of MES through the sample volume. (author)

  19. A novel device for the occlusion of left atrial appendage: an experimental study in canine models

    International Nuclear Information System (INIS)

    Yang Zhihong; Qin Yongwen; Wu Hong; Hu Jianqiang; Wang Shengqiang; Ding Zhongru; Liu Zongjun

    2011-01-01

    Objective: To evaluate the feasibility, safety and biocompatibility of a novel device designed by the authors for the occlusion of left atrial appendage (LAA) in canine models. Methods: The occlusion of LAA was performed in 20 experimental dogs by using a novel LAA occluder, which was delivered to the LAA through a transseptal catheter. During the period of 2 weeks to 6 months after the procedure, the dogs were kept under observation for the device healing, migration, perforation and the formation of thrombus. Both scanning electron microscope (SEM) and transmission electron microscope (TEM) were used to examine the endothelial growth on the surface of the occluder and the structure of the endothelial cells. Results: Of the total 20 dogs, the novel device was successfully implanted in 14. The LAA was occluded completely in 13 dogs. No mobile thrombi caused by the implantation procedure were observed. Endothelialization of the atrium-facing surface was observed at one month after the procedure, and the surface was completely covered with endothelial cells at 3 months after the treatment, which was confirmed by gross, histological and SEM examinations. TEM examination showed that the structure of endothelial cells, the mitochondrion and sarcomere of atrial cardiocyte were all normal. Gross and light microscopic examination of the kidney, lung spleen and liver showed that there was no evidence of embolism or infarction. Conclusion: The novel device is safe and feasible for the occlusion of the LAA in experimental dogs. Further study is needed to observe its long-term safety. (authors)

  20. Velocity encoded cardiovascular magnetic resonance to assess left atrial appendage emptying

    Directory of Open Access Journals (Sweden)

    Muellerleile Kai

    2012-06-01

    Full Text Available Abstract Background The presence of impaired left atrial appendage (LAA function identifies patients who are prone to thrombus formation in the LAA and therefore being at high risk for subsequent cardioembolic stroke. LAA function is typically assessed by measurements of LAA emptying velocities using transesophageal echocardiography (TEE in clinical routine. This study aimed at evaluating the feasibility of assessing LAA emptying by velocity encoded (VENC cardiovascular magnetic resonance (CMR. Methods This study included 30 patients with sinus rhythm (n = 18 or atrial fibrillation (n = 12. VENC-CMR velocity measurements were performed perpendicular to the orifice of the LAA. Peak velocities were measured of passive diastolic LAA emptying (e-wave in all patients. Peak velocities of active, late-diastolic LAA emptying (a-wave were assessed in patients with sinus rhythm. Correlation and agreement was analyzed between VENC-CMR and TEE measurements of e- and a-wave peak velocities. Results A significant correlation and good agreement was found between VENC-CMR and TEE measurements of maximal e-wave velocities (r = 0.61, P  Conclusions The assessment of active and passive LAA emptying by VENC-CMR is feasible. Further evaluation is required of potential future clinical applications such as risk stratification for cardioembolic stroke.

  1. Left atrial appendage morphology in patients with suspected cardiogenic stroke without known atrial fibrillation.

    Directory of Open Access Journals (Sweden)

    Miika Korhonen

    Full Text Available The left atrial appendage (LAA is the typical origin for intracardiac thrombus formation. Whether LAA morphology is associated with increased stroke/TIA risk is controversial and, if it does, which morphological type most predisposes to thrombus formation. We assessed LAA morphology in stroke patients with cryptogenic or suspected cardiogenic etiology and in age- and gender-matched healthy controls. LAA morphology and volume were analyzed by cardiac computed tomography in 111 patients (74 males; mean age 60 ± 11 years with acute ischemic stroke of cryptogenic or suspected cardiogenic etiology other than known atrial fibrillation (AF. A subgroup of 40 patients was compared to an age- and gender-matched control group of 40 healthy individuals (21 males in each; mean age 54 ± 9 years. LAA was classified into four morphology types (Cactus, ChickenWing, WindSock, CauliFlower modified with a quantitative qualifier. The proportions of LAA morphology types in the main stroke group, matched stroke subgroup, and control group were as follows: Cactus (9.0%, 5.0%, 20.0%, ChickenWing (23.4%, 37.5%, 10.0%, WindSock (47.7%, 35.0%, 67.5%, and CauliFlower (19.8%, 22.5%, 2.5%. The distribution of morphology types differed significantly (P<0.001 between the matched stroke subgroup and control group. The proportion of single-lobed LAA was significantly higher (P<0.001 in the matched stroke subgroup (55% than the control group (6%. LAA volumes were significantly larger (P<0.001 in both stroke study groups compared to controls patients. To conclude, LAA morphology differed significantly between stroke patients and controls, and single-lobed LAAs were overrepresented and LAA volume was larger in patients with acute ischemic stroke of cryptogenic or suspected cardiogenic etiology.

  2. Plain chest PA evaluation of left atrial thrombosis in mitral valvular disease

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Yeon Myung; Park, Jae Hyung; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1984-09-15

    Conventional posteroanterior chest radiographs of 73 patients with mitral valve disease who had had surgery were analyzed, and particular attention was directed to the absence of the convexity of the left lower mid cardiac border (left atrial segment) and to the relation with duration of illness, atrial fibrillation, pulmonary capillary wedge pressure (PCWP) as well as surgical findings. The results obtained are as follows: 1. The flatness or concavity of this segment, despite other evidence of left atrial enlargement, was observed in eleven (64.7%) of 17 patients who had left atrial thrombosis and in six (10.7%) of 56 patients who did not have thrombosis (false positive diagnosis). Six (35.5%) of the 17 patients who had left atrial thrombosis did not this findings on radiographs (false positive diagnosis). Six (35.3%) of the 17 patients who had left atrial thrombosis did not show this finding on radiographs (false positive diagnosis). Therefore, the accuracy in the diagnosis of thrombosis of left atrium wa 64.7% (eleven of seventeen) for patients who had thrombosis of left atrium. 2. The atrial fibrillation was observed in sixteen (94.1%)of 17 patients who had left atrial thrombosis. So, correlation between the presence of left atrial thrombosis and atrial fibrillation wa evident. But there was no correlation between the duration of illness of the PCWP of patients and the presence of left atrial thrombosis.

  3. Plain chest PA evaluation of left atrial thrombosis in mitral valvular disease

    International Nuclear Information System (INIS)

    Choo, Yeon Myung; Park, Jae Hyung; Han, Man Chung

    1984-01-01

    Conventional posteroanterior chest radiographs of 73 patients with mitral valve disease who had had surgery were analyzed, and particular attention was directed to the absence of the convexity of the left lower mid cardiac border (left atrial segment) and to the relation with duration of illness, atrial fibrillation, pulmonary capillary wedge pressure (PCWP) as well as surgical findings. The results obtained are as follows: 1. The flatness or concavity of this segment, despite other evidence of left atrial enlargement, was observed in eleven (64.7%) of 17 patients who had left atrial thrombosis and in six (10.7%) of 56 patients who did not have thrombosis (false positive diagnosis). Six (35.5%) of the 17 patients who had left atrial thrombosis did not this findings on radiographs (false positive diagnosis). Six (35.3%) of the 17 patients who had left atrial thrombosis did not show this finding on radiographs (false positive diagnosis). Therefore, the accuracy in the diagnosis of thrombosis of left atrium wa 64.7% (eleven of seventeen) for patients who had thrombosis of left atrium. 2. The atrial fibrillation was observed in sixteen (94.1%)of 17 patients who had left atrial thrombosis. So, correlation between the presence of left atrial thrombosis and atrial fibrillation wa evident. But there was no correlation between the duration of illness of the PCWP of patients and the presence of left atrial thrombosis.

  4. Left atrial spindle cell sarcoma – Case report

    Directory of Open Access Journals (Sweden)

    Nihar Mehta

    2012-07-01

    Full Text Available Primary spindle cell sarcoma of the left atrium is an extremely rare tumour. Surgical excision is the mainstay of treatment since it responds poorly to chemotherapy or radiotherapy. In spite of all the treatment, the prognosis remains poor due to inadvertent delay in diagnosis, few therapeutic options and propensity to metastasize. We present a 47-year-old male who underwent a surgical excision of a left atrial mass in February 2010. It was proved to be a high-grade spindle cell sarcoma on histopathology. He presented again in October 2010 with recurrence of the tumour for which he was re-operated. However, the tumour recurred again within one month, to which the patient succumbed.

  5. Early changes in left atrial volume after acute myocardial infarction

    DEFF Research Database (Denmark)

    Bakkestrom, R.; Andersen, Mads J; Ersboll, M.

    2016-01-01

    . The objective was to assess changes in LA volume early after MI in patients with diastolic dysfunction and the relation to invasive hemodynamics and natriuretic peptides. Methods: 62 patients with left ventricle ejection fraction (LVEF) >= 45%, diastolic E/e' > 8 and LA volume index >34 ml/m(2) within 48 h......Background: Dilatation of left atrium (LA) reflects chronic LA pressure or volume overload that possesses considerable prognostic information. Little is known regarding the interaction between LA remodeling after acute myocardial infarction (MI) and left atrial pressure at rest and during exercise...... of MI were enrolled. After 1 and 4 months blood sampling, echocardiography and right heart catheterization were performed during exercise test. Results: LA remodeling was considered in patients with a change from mild (35-41 ml/m(2)), to severe (>48ml/m(2)) dilatation after 4 months (Found in 22...

  6. Left Atrial Systolic Force in Asymptomatic Aortic Stenosis

    DEFF Research Database (Denmark)

    Cioffi, Giovanni; Cramariuc, Dana; Dalsgaard, Morten

    2011-01-01

    LASF in the total study population was 21 ± 14 kdynes/cm(2) . The determinants of LASF were higher age, heart rate, body mass index, systolic blood pressure, left ventricular (LV) mass, mitral peak early velocity, maximal LA volume, and longer mitral deceleration time (multiple R(2) = 0.37, P ...Background: There is a limited knowledge about left atrial (LA) systolic force (LASF) and its key determinants in patients with asymptomatic mild-moderate aortic stenosis (AS). Methods: We used baseline clinic and echocardiographic data from 1,566 patients recruited in the simvastatin ezetimibe...... in aortic stenosis study evaluating the effect of placebo-controlled combined simvastatin and ezetimibe treatment in asymptomatic AS. The LASF was calculated by Manning's method. Low and high LASF were defined as 95th percentile of the distribution within the study population, respectively. Results: Mean...

  7. Left atrial isolation associated with mitral valve operations.

    Science.gov (United States)

    Graffigna, A; Pagani, F; Minzioni, G; Salerno, J; Viganò, M

    1992-12-01

    Surgical isolation of the left atrium was performed for the treatment of chronic atrial fibrillation secondary to valvular disease in 100 patients who underwent mitral valve operations. From May 1989 to September 1991, 62 patients underwent mitral valve operations (group I); 19, mitral valve operations and DeVega tricuspid annuloplasty (group II); 15, mitral and aortic operations (group III); and 4, mitral and aortic operations and DeVega tricuspid annuloplasty (group IV). Left atrial isolation was performed, prolonging the usual left paraseptal atriotomy toward the left fibrous trigone anteriorly and the posteromedial commissure posteriorly. The incision was conducted a few millimeters apart from the mitral valve annulus, and cryolesions were placed at the edges to ensure complete electrophysiological isolation of the left atrium. Operative mortality accounted for 3 patients (3%). In 79 patients (81.4%) sinus rhythm recovered and persisted until discharge from the hospital. No differences were found between the groups (group I, 80.7%; group II, 68.5%; group III, 86.7%; group IV, 75%; p = not significant). Three late deaths (3.1%) were registered. Long-term results show persistence of sinus rhythm in 71% of group I, 61.2% of group II, 85.8% of group III, and 100% of group IV. The unique risk factor for late recurrence of atrial fibrillation was found to be preoperative atrial fibrillation longer than 6 months. Due to the satisfactory success rate in recovering sinus rhythm, we suggest performing left atrial isolation in patients with chronic atrial fibrillation undergoing valvular operations.

  8. Left atrial systolic force in hypertensive patients with left ventricular hypertrophy: the LIFE study

    DEFF Research Database (Denmark)

    Chinali, M.; Simone, G. de; Wachtell, K.

    2008-01-01

    In hypertensive patients without prevalent cardiovascular disease, enhanced left atrial systolic force is associated with left ventricular hypertrophy and increased preload. It also predicts cardiovascular events in a population with high prevalence of obesity. Relations between left atrial...... systolic force and left ventricular geometry and function have not been investigated in high-risk hypertrophic hypertensive patients. Participants in the Losartan Intervention For Endpoint reduction in hypertension echocardiography substudy without prevalent cardiovascular disease or atrial fibrillation (n...... = 567) underwent standard Doppler echocardiography. Left atrial systolic force was obtained from the mitral orifice area and Doppler mitral peak A velocity. Patients were divided into groups with normal or increased left atrial systolic force (>14.33 kdyn). Left atrial systolic force was high in 297...

  9. Left atrial myxoma, ruptured chordae tendinae causing mitral regurgitation and coronary artery disease

    Directory of Open Access Journals (Sweden)

    Bhupesh Kumar

    2014-01-01

    Full Text Available Mitral regurgitation is uncommon with left atrial myxoma. The echocardiographic assessment of presence of mitral regurgitation and its severity are impaired by the presence of left atrial myxoma. We describe an uncommon association of left atrial myxoma with coronary artery disease and mitral regurgitation. MR was reported as mild on pre-operative transthoracic echocardiography but found to be severe due to ruptured chordae tendinae during intra-operative transesophageal echocardiography, which lead to change in the surgical plan to mitral valve replacement in addition to excision of myxoma.

  10. Ticagrelor, but not clopidogrel active metabolite, displays antithrombotic properties in the left atrial endocardium.

    Science.gov (United States)

    Reiner, Martin F; Breitenstein, Alexander; Holy, Erik W; Glanzmann, Martina; Amstalden, Heidi; Stämpfli, Simon F; Bonetti, Nicole R; Falk, Volkmar; Keller, Stephan; Savarese, Gianluigi; Benussi, Stefano; Maisano, Francesco; Lüscher, Thomas F; Beer, Jürg H; Steffel, Jan; Camici, Giovanni G

    2017-03-21

    Oral anticoagulation is considered standard therapy for stroke prevention in atrial fibrillation (AF). Endocardial activation triggers expression of pro-thrombotic mediators including tissue factor (TF) and plasminogen activator inhibitor-1 (PAI-1), and contributes to thrombus formation in the left atrial appendage (LAA) of AF patients. Recently, pleiotropic effects of specific P2Y12 receptor antagonists were demonstrated; however, whether these drugs possess antithrombotic effects on LAA endocardial cells currently remains unknown. LAA were obtained from 14 patients with known AF undergoing elective cardiac surgery including LAA removal at the University Hospital Zurich. LAA endocardial cells were isolated and pre-incubated with ticagrelor (10-7, 10-6, 10-5M) or clopidogrel active metabolite (CAM) (1.5 × 10-8, 1.5 × 10-7, 1.5 × 10-6 M) before stimulation with tumour necrosis factor-alpha (TNF-α) (10 ng/mL). Finally, TF and PAI-1 expression and activity were analysed. Ticagrelor, unlike CAM, concentration dependently decreased TNF-α-induced TF expression and TF activity in LAA endocardial cells. Further, ticagrelor, but not CAM reduced PAI-1 expression and enzyme activity in TNF-α-stimulated LAA endocardial cells. In contrast, TF pathway inhibitor (TFPI) remained unaffected by both dugs. Ticagrelor, but not CAM, reduces expression and activity of TF and PAI-1 in LAA endocardial cells isolated from patients with AF, indicating possible local antithrombotic effects. Such pleiotropic properties of ticagrelor may contribute to a reduction in thromboembolic complications in patients with AF. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  11. Left ventricular filling under elevated left atrial pressure

    Science.gov (United States)

    Gaddam, Manikantam; Samaee, Milad; Santhanakrishnan, Arvind

    2017-11-01

    Left atrial pressure (LAP) is elevated in diastolic dysfunction, where left ventricular (LV) filling is impaired due to increase in ventricular stiffness. The impact of increasing LAP and LV stiffness on intraventricular filling hemodynamics remains unclear. We conducted particle image velocimetry and hemodynamics measurements in a left heart simulator (LHS) under increasing LAP and LV stiffness at a heart rate of 70 bpm. The LHS consisted of a flexible-walled LV physical model fitted within a fluid-filled chamber. LV wall motion was generated by a piston pump that imparted pressure fluctuations in the chamber. Resistance and compliance elements in the flow loop were adjusted to obtain bulk physiological hemodynamics in the least stiff LV model. Two LV models of increasing stiffness were subsequently tested under unchanged loop settings. LAP was varied between 5-20 mm Hg for each LV model, by adjusting fluid level in a reservoir upstream of the LV. For constant LV stiffness, increasing LAP lowered cardiac output (CO), while ejection fraction (EF) and E/A ratio were increased. For constant LAP, increasing LV stiffness lowered CO and EF, and increased E/A ratio. The implications of these altered hemodynamics on intraventricular filling vortex characteristics will be presented.

  12. Plasmacytoid lymphoma within a left atrial myxoma: a rare coincidental dual pathology.

    Science.gov (United States)

    White, Ralph W; Hirst, Natalie A; Edward, Sara; Nair, Unnikrishnan R

    2010-01-01

    Primary malignant cardiac neoplasms are extremely rare. The occurrence of a malignant lymphoid tumour within a left atrial myxoma is highly atypical, with only one such case previously reported. Here, we describe a patient who presented with symptoms and signs of a left atrial myxoma. Subsequent specimen histology demonstrated the presence of lymphoma within the myxoma. We discuss the importance of histological diagnosis in order to best direct treatment and prognosis of such cases.

  13. LEFT ATRIAL FUNCTION: MODERN ASSESSMENT METHODS AND CLINICAL SIGNIFICANCE

    Directory of Open Access Journals (Sweden)

    E. N. Pavlyukova

    2017-01-01

    Full Text Available Assessment of the left atrial (LA function is important aspect of comprehensive cardiovascular system estimation. Many cardiac diseases make an impact to LA work either by direct affect on myocardium or hemodynamic condition changing. It is considered, LA and left ventricle diastolic pressure is interrelated, thus without mitral valve disease LA expanding is a sign of LV filling pressure augmentation. Examination of LA size and function by analysis of atrial reservoir, conduit, and booster pump can predict cardiovascular outcomes in patients with cardiomyopathy, ischemic heart disease and valvular heart disease. The last two decades gave new technologies to accurate and comprehensive LA mechanics estimation, in the first place related to tissue Doppler imaging. Atrial strain and strain rate obtained using two-dimensional speckle-tracking echocardiography have proved to be feasible and reproducible techniques to evaluate LA mechanics.In physiological settings, LA is a highly expandable chamber with relatively low pressures. However in the presence of acute and chronic injury, LA wall stretches. LA stretching is a hallmark of structure changing with myocardial fibrosis and has influence on LA strain and strain rate. LA strain estimation could be useful in the prediction of sinus rhythm restoration and maintenance after cardioversion and catheter ablation. Low values of global longitudinal LA strain indicate irreversible LA remodeling and are related to the atrial fibrillation progression from paroxysmal to permanent forms. The most interesting in these circumstances is the potential contribution of echocardiography to thromboembolic risk stratification in atrial fibrillation and invasive procedures such as atrial ablation. Therefore, at present, the main task is to understand the ways of clinical application of data  obtained during the LA study.

  14. Left atrial appendage closure: a new technique for clinical practice.

    Science.gov (United States)

    John Camm, A; Colombo, Antonio; Corbucci, Giorgio; Padeletti, Luigi

    2014-03-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. It is associated with increased risk for stroke mainly due to cardiac embolism from the left atrial appendage (LAA). Occlusion of the LAA by means of a device represents a valid alternative to oral anticoagulation, mainly in patients who cannot tolerate this therapy because of a high bleeding risk. Recent data on the endocardial device WATCHMAN show encouraging results for this patient population in terms of stroke risk reduction compared to the expected rate as well as in terms of implant success. This article reviews all relevant publications related to the main surgical and transcatheter devices used for LAA closure (LAAC). PROTECT-AF, the first prospective randomized trial conducted on this technique, showed that LAA occlusion using the WATCHMAN was noninferior to warfarin for a combined end-point in patients with nonvalvular AF. There is a lack of large-scale randomized trials on long-term stroke risk in patients submitted to LAAC. Most studies are relatively small and focus on the comparison of different surgical techniques with regard to complete/incomplete closure success. More recently, PROTECT-AF long-term results (4-year follow-up) demonstrated that LAAC was statistically superior to warfarin in terms of efficacy. This review concludes that it is now appropriate to consider these techniques for patients with AF who are at high risk for stroke for whom effective conventional or novel anticoagulant therapy is not available or who present problems in managing drug treatment. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. Left Atrial Mechanical Function and Global Strain in Hypertrophic Cardiomyopathy.

    Directory of Open Access Journals (Sweden)

    Kyung-Jin Kim

    Full Text Available Atrial fibrillation is the most common arrhythmia and is associated with adverse outcomes in hypertrophic cardiomyopathy (HCM. Although left atrial (LA remodeling and dysfunction are known to associate with the development of atrial fibrillation in HCM, the changes of the LA in HCM patients remain unclear. This study aimed to evaluate the changes in LA size and mechanical function in HCM patients compared to control subjects and to determine the characteristics of HCM associated with LA remodeling and dysfunction.Seventy-nine HCM patients (mean age, 54 ± 11 years; 76% were men were compared to 79 age- and sex-matched controls (mean age, 54 ± 11 years; 76% were men and 20 young healthy controls (mean age, 33 ± 5 years; 45% were men. The LA diameter, volume, and mechanical function, including global strain (ε, were evaluated by 2D-speckle tracking echocardiography. The phenotype of HCM, maximal left ventricular (LV wall thickness, LV mass, and presence and extent of late gadolinium enhancement (LGE were evaluated with cardiac magnetic resonance imaging.HCM patients showed increased LA volume index, impaired reservoir function, and decreased LA ε compared to the control subjects. When we divided the HCM group according to a maximal LA volume index (LAVImax of 38.7 ml/m2 or LA ε of 21%, no significant differences in the HCM phenotype and maximal LV wall thickness were observed for patients with LAVImax >38.7 ml/m2 or LA ε ≤21%. Conversely, the LV mass index was significantly higher both in patients with maximal LA volume index >38.7 ml/m2 and with LA ε ≤21% and was independently associated with LAVImax and LA ε. Although the LGE extent was increased in patients with LA ε ≤21%, it was not independently associated with either LAVImax or LA ε.HCM patients showed progressed LA remodeling and dysfunction; the determinant of LA remodeling and dysfunction was LV mass index rather than LV myocardial fibrosis by LGE-magnetic resonance

  16. The Relationship between Left Atrial Mechanical Function and Functional Capacity in Mitral Stenosis

    Directory of Open Access Journals (Sweden)

    Mücahit Yetim

    2013-11-01

    Full Text Available Aim: In this study, left atrial functions of patients with rheumatic mitral stenosis and sinus rhythm, which was determined by transthorasic echocardiography, was compared with those of healhty subjects and the association of left atrial functions with functional capacity was investigated in subgroup analyses.   Material and methods: 32 patients with isolated rheumatic mitral stenosis (median age was 39.1±11  (group 1 and 20 patients in the control group ( median age was 37±8,2 (group 2 were enrolled to study. The average mitral valve area of patients was 1.1±0,3 cm2. When patients were divided according to New York Heart Association (NYHA classification ; 16 patients were NYHA 2 (Grup A and 16 patients were NYHA 3 (Grup B. There were not any asymptomatic patients and no patients were NYHA 4. Left atrium diameters, left atrium volume, left atrium fractional area change and left atrium ejection fractions  of patients in these groups were calculated.   Results: The demographic characteristics of patients is shown in table 1. Left atrium ejection fraction (LAEF and left atrium fractional area change (LAFAC that were determined echocardiographycally were significantly lower in patients with mitral stenosis (32 ± 5, 44 ± 3; p<0.001- 25 ± 11, 32 ± 6; p< 0.02.  When patients were divided according to New York Heart Association (NYHA classification ; 16 patients were NYHA 2 (Grup A and 16 patients were NYHA 3 (Grup B. There were not any asymptomatic patients and no patients were NYHA 4. The clinical and echocardiographic data of patients are shown in table 2. Despite of similar mitral valve area and average mitral gradient ,systolic pulmonary artery pressure was found to be higher in symptomatic group. But there was no difference between left atrial functions of the two groups.   Discussion: In this study we have shown that left atrial functions determined echocardiographically  can decline in patients with mitral stenosis but the

  17. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study.

    Science.gov (United States)

    Sugimoto, Tadafumi; Robinet, Sébastien; Dulgheru, Raluca; Bernard, Anne; Ilardi, Federica; Contu, Laura; Addetia, Karima; Caballero, Luis; Kacharava, George; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; van de Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Go, Yun Yun; Marchetta, Stella; Nchimi, Alain; Rosca, Monica; Calin, Andreea; Moonen, Marie; Cimino, Sara; Magne, Julien; Cosyns, Bernard; Galli, Elena; Donal, Erwan; Habib, Gilbert; Esposito, Roberta; Galderisi, Maurizio; Badano, Luigi P; Lang, Roberto M; Lancellotti, Patrizio

    2018-02-23

    To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.

  18. Left atrial function in heart failure with impaired and preserved ejection fraction.

    Science.gov (United States)

    Fang, Fang; Lee, Alex Pui-Wai; Yu, Cheuk-Man

    2014-09-01

    Left atrial structural and functional changes in heart failure are relatively ignored parts of cardiac assessment. This review illustrates the pathophysiological and functional changes in left atrium in heart failure as well as their prognostic value. Heart failure can be divided into those with systolic dysfunction and heart failure with preserved ejection fraction (HFPEF). Left atrial enlargement and dysfunction commonly occur in systolic heart failure, in particular, in idiopathic dilated cardiomyopathy. Atrial enlargement and dysfunction also carry important prognostic value in systolic heart failure, independently of known parameters such as left ventricular ejection fraction. In HFPEF, there is evidence of left atrial enlargement, impaired atrial compliance, and reduction of atrial pump function. This occurs not only at rest but also during exercise, indicating significant impairment of atrial contractile reserve. Furthermore, atrial dyssynchrony is common in HFPEF. These factors further contribute to the development of new onset or progression of atrial arrhythmias, in particular, atrial fibrillation. Left atrial function is an integral part of cardiac function and its structural and functional changes in heart failure are common. As changes of left atrial structure and function have different clinical implications in systolic heart failure and HFPEF, routine assessment is warranted.

  19. Validation of Left Atrial Volume Estimation by Left Atrial Diameter from the Parasternal Long-Axis View.

    Science.gov (United States)

    Canciello, Grazia; de Simone, Giovanni; Izzo, Raffaele; Giamundo, Alessandra; Pacelli, Filomena; Mancusi, Costantino; Galderisi, Maurizio; Trimarco, Bruno; Losi, Maria-Angela

    2017-03-01

    Measurement of left atrial (LA) volume (LAV) is recommended for quantification of LA size. Only LA anteroposterior diameter (LAd) is available in a number of large cohorts, trials, or registries. The aim of this study was to evaluate whether LAV may be reasonably estimated from LAd. One hundred forty consecutive patients referred to our outpatient clinics were prospectively enrolled to measure LAd from the long-axis view on two-dimensional echocardiography. LA orthogonal dimensions were also taken from apical four- and two-chamber views. LAV was measured using the Simpson, area-length, and ellipsoid (LAV e ) methods. The first 70 patients were the learning series and the last 70 the testing series (TeS). In the learning series, best-fitting regression analysis of LAV-LAd was run using all LAV methods, and the highest values of F were chosen among the regression equations. In the TeS, the best-fitting regressions were used to estimate LAV from LAd. In the learning series, the best-fitting regression was linear for the Spearman method (r 2  = 0.62, F = 111.85, P = .0001) and area-length method (r 2  = 0.62, F = 112.24, P = .0001) and powered for the LAV e method (r 2  = 0.81, F = 288.41, P = .0001). In the TeS, the r 2 value for LAV prediction was substantially better using the LAV e method (r 2  = 0.89) than the Simpson (r 2  = 0.72) or area-length (r 2  = 0.70) method, as was the intraclass correlation (ρ = 0.96 vs ρ = 0.89 and ρ = 0.89, respectively). In the TeS, the sensitivity and specificity of LA dilatation by the estimated LAV e method were 87% and 90%, respectively. LAV can be estimated from LAd using a nonlinear equation with an elliptical model. The proposed method may be used in retrospective analysis of existing data sets in which determination of LAV was not programmed. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  20. Percutaneous left atrial appendage occlusion: Effect of device positioning on outcome.

    Science.gov (United States)

    Wolfrum, Mathias; Attinger-Toller, Adrian; Shakir, Samera; Gloekler, Steffen; Seifert, Burkhardt; Moschovitis, Aris; Khattab, Ahmed; Maisano, Francesco; Meier, Bernhard; Nietlispach, Fabian

    2016-10-01

    The study in patients with percutaneous left atrial appendage (LAA) occlusion investigates clinical outcomes according to the position of the Amplatzer Cardiac Plug (ACP) disc. The ACP consists of a disc and an anchoring lobe. The disc is meant to cover the ostium of the LAA, but frequently retracts partially or completely into the neck of the LAA. It is not known whether a retracted disc affects outcome. Outcomes of 169 consecutive patients (age 73.1 ± 10.4 years; 76% male) with successful LAA closure were analyzed according to the position of the ACP disc: group A had complete coverage of the LAA ostium; in group B the disc prolapsed partially or completely into the LAA-neck. Transesophageal echocardiography was performed 1-6 months after ACP implantation. The safety endpoint was the composite of clinically significant pericardial effusion, device embolization, procedure-related stroke/transient ischemic attack (TIA), major bleeding, or device thrombus. The efficacy endpoint was the composite of death, neurological events (ischemic and hemorrhagic stroke, TIA), or systemic embolism during follow-up. Group A comprised 76 patients (age 73.0 ± 9.9 years; 74% male) and group B 93 patients (age 73.3 ± 10.9 years; 79% male). Mean CHA 2 DS 2 -Vasc score and HASBLED score were 4.2 ± 1.7 (group A 4.3 ± 1.6; group B 4.2 ± 1.8) and 2.9 ± 1.1 (group A 2.9 ± 1.0; group B 3.0 ± 1.2), respectively. Mean follow-up of the study population was 13.0 ± 10.4 months. Overall, the composite safety and efficacy endpoints occurred in 20 (12%) and 6 patients (4%), respectively. There was no significant difference between groups A and B in the occurrence of the safety endpoint (13% vs. 11%, P = 0.64), or the efficacy endpoint (4% vs. 3%, P = 1.0). No evidence for a difference in the occurrence of the safety and efficacy endpoint was found between patients with complete vs. incomplete ACP disc coverage of the LAA ostium. The risk of

  1. Assessment of normal left atrial appendage anatomy and function over gender and ages by dynamic cardiac CT

    International Nuclear Information System (INIS)

    Boucebci, Samy; Velasco, Stephane; Duboe, Pier-Olivier; Tasu, Jean-Pierre; Pambrun, Thomas; Ingrand, Pierre

    2016-01-01

    The aim of this study was to evaluate variations in anatomy and function according to age and gender using cardiac computed tomography (CT) in a large prospective cohort of healthy patients. The left atrial appendage (LAA) is considered the most frequent site of intracardiac thrombus formation. However, variations in normal in vivo anatomy and function according to age and gender remain largely unknown. Three-dimensional (3D) cardiac reconstructions of the LAA were performed from CT scans of 193 consecutive patients. Parameters measured included LAA number of lobes, anatomical position of the LAA tip, angulation measured between the proximal and distal portions, minimum (iVol min ) and maximum (iVol max ) volumes indexed to body surface area (BSA), and ejection fraction (LAAEF). Relationship with age was assessed for each parameter. We found that men had longer and wider LAAs. The iVol min and iVol max increased by 0.23 and 0.19 ml per decade, respectively, while LAAEF decreased by 2 % per decade in both sexes. Although LAA volumes increase, LAAEF decreases with age in both sexes. (orig.)

  2. Assessment of normal left atrial appendage anatomy and function over gender and ages by dynamic cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Boucebci, Samy; Velasco, Stephane; Duboe, Pier-Olivier; Tasu, Jean-Pierre [University of Poitiers, University Hospital, Department of Radiology, Poitiers (France); Pambrun, Thomas [University of Poitiers, University Hospital, Department of Cardiology, Poitiers (France); Ingrand, Pierre [University of Poitiers, University Institute of Public Health, Poitiers (France)

    2016-05-15

    The aim of this study was to evaluate variations in anatomy and function according to age and gender using cardiac computed tomography (CT) in a large prospective cohort of healthy patients. The left atrial appendage (LAA) is considered the most frequent site of intracardiac thrombus formation. However, variations in normal in vivo anatomy and function according to age and gender remain largely unknown. Three-dimensional (3D) cardiac reconstructions of the LAA were performed from CT scans of 193 consecutive patients. Parameters measured included LAA number of lobes, anatomical position of the LAA tip, angulation measured between the proximal and distal portions, minimum (iVol{sub min}) and maximum (iVol{sub max}) volumes indexed to body surface area (BSA), and ejection fraction (LAAEF). Relationship with age was assessed for each parameter. We found that men had longer and wider LAAs. The iVol{sub min} and iVol{sub max} increased by 0.23 and 0.19 ml per decade, respectively, while LAAEF decreased by 2 % per decade in both sexes. Although LAA volumes increase, LAAEF decreases with age in both sexes. (orig.)

  3. Etiologic significance of enlargement of the left atrial appendage in adults

    International Nuclear Information System (INIS)

    Green, C.E.; Kelley, M.J.; Higgins, C.B.

    1982-01-01

    Fifty-one patients were divided into two groups: 20 patients with proven rheumatic mitral valve disease (RMVD) and 31 patients with left atrial enlargement (LAE) of a nonrheumatic etiology. The latter group included patients with ischemic papillary muscle dysfunction, mitral valve prolapse, and congestive cardiomyopathy. Radiographic studies showed that enlargement of the left atrial appendage (LAAE) was present in 18 of 20 rheumatics but in only one of 31 nonrheumatics. There was no direct relationship between enlargement of the LAA and radiographic or echocardiographic left atrial size, degree of pulmonary venous hypertension (PVH), or presence of atrial fibrillation. It is postulated that rheumatic influammation of the LAA allows it to dilate out of proportion to the body of the left atrium. In the adult patient with radiographic findings of PVH, LAAE is a valuable and specific radiographic sign of rheumatic mitral valve disease

  4. Obese Hypertensive Men Have Lower Circulating Proatrial Natriuretic Peptide Concentrations Despite Greater Left Atrial Size

    DEFF Research Database (Denmark)

    Asferg, Camilla L; Andersen, Ulrik B; Linneberg, Allan

    2018-01-01

    BACKGROUND: Obese persons have lower circulating natriuretic peptide (NP) concentrations. It has been proposed that this natriuretic handicap plays a role in obesity-related hypertension. In contrast, hypertensive patients with left atrial enlargement have higher circulating NP concentrations....... On this background, we investigated whether obese hypertensive men could have lower circulating NP concentrations despite evidence of pressure-induced greater left atrial size. METHODS: We examined 98 obese men (body mass index [BMI] ≥ 30.0 kg/m2) and 27 lean normotensive men (BMI 20.0-24.9 kg/m2). All men were...... using echocardiography, and we measured fasting serum concentrations of midregional proatrial NP (MR-proANP). RESULTS: Of the 98 obese men, 62 had hypertension and 36 were normotensive. The obese hypertensive men had greater left atrial size (mean ± SD: 28.7 ± 6.0 ml/m2) compared with the lean...

  5. Left atrial size in patients with cryptogenic stroke as a predictor of occurrence of atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Antonio Cruz Culebras

    2017-04-01

    Full Text Available Objective: To determine whether the left atrial size can predict the development of atrial fibrillation (AF in patients with embolic stroke of undetermined source (ESUS. Methods: Patients with ischemic stroke were included prospectively (January 2015-July 2015 when ESUS was suspected. Clinical and cardiac imaging data were recorded. Patients with cardiac failure were excluded. Results: a total of 55 patients were included. Medium age was 71 years. The proportion of patients who developed AF during the follow-up (1 year was 23, 63%. 10 % of patients did not have any vascular risk factor. Basal ECG was normal in 98% of cases. The left atrial size volume was 36, 08 ml in patients who developed AF and 27, 14 ml in patients who did not. Conclusions: In patients with ESUS, left atrial size dimensions do not predict the occurrence of AF.

  6. Percutaneous closure of the left atrial appendage in patients with diabetes mellitus.

    Science.gov (United States)

    Azizy, Obayda; Rammos, Christos; Lehmann, Nils; Rassaf, Tienush; Kälsch, Hagen

    2017-09-01

    Left atrial appendage closure is a preventive treatment of atrial fibrillation-related thrombo-embolism. Patients with diabetes mellitus have increased risk for a negative outcome in percutaneous cardiac interventions. We assessed whether percutaneous left atrial appendage closure is safe and effective in patients with diabetes mellitus. We included 78 patients (mean age of 74.4 ± 8.3 years) with indication for left atrial appendage closure in an open-label observational single-centre study. Patients with diabetes mellitus ( n = 31) were at higher thrombo-embolic and bleeding risk (CHA 2 DS 2 -VASc: 4.5 ± 0.9, HAS-BLED: 4.7 ± 0.7) compared to patients without diabetes mellitus ( n = 47, CHA 2 DS 2 -VASc: 3.5 ± 1.0, HAS-BLED: 4.1 ± 0.8; p diabetes mellitus (Euro II-Score: 6.6 ± 3.7 vs 3.9 ± 1.9, p diabetes mellitus had no events ( p = 0.672). Follow-up of 6 months revealed no bleeding complication in both groups. No stroke occurred in follow-up, and left atrial appendage flow velocity reduction (55.6 ± 38.6 vs 51.4 ± 19.1 cm/s, p = 0.474) and rate of postinterventional leakage in the left atrial appendage were comparable (0% vs 2.1%, p = 0.672). Despite patients with diabetes mellitus are high-risk patients, the outcome of percutaneous left atrial appendage closure is similar to patients without diabetes mellitus.

  7. Magnetic resonance imaging and angiography of the brain in embolic left atrial myxoma

    International Nuclear Information System (INIS)

    Marazuela, M.; Yebra, M.; Diego, J.; Durantez, A.; Garcia-Merino, A.; Brasa, J.M.

    1989-01-01

    A case of left atrial myxoma presenting exclusively with neurological symptoms, studies with magnetic resonance imaging (MRI) combined with cerebral angiography and computed tomography (CT) is reported. Typical angiographic findings suggested the diagnosis of myxoma. MRI showed multiple ischemic lesions disseminated throughout the entire brain, some of which had been clinically asymptomatic. Because of its sensitivity in identifying small cerebral infarcts, MRI should prove in the future to be a first-choice technique in the evaluation of the presence of an extent of cerebral involvement in embolic left atrial myxoma. (orig.)

  8. Inadvertent puncture of the aortic noncoronary cusp during postoperative left atrial tachycardia ablation

    Directory of Open Access Journals (Sweden)

    Dursun Aras, MD

    2015-08-01

    Full Text Available Transseptal catheterization has become part of the interventional electrophysiologist׳s technical armamentarium since the development of left atrial catheter ablation and percutaneous technologies for treating mitral and aortic valve disease. Although frequently performed, the procedure׳s most feared complication is aortic root penetration. Focal atrial tachycardia has been described as the most common late sequela of surgical valve replacements. We present a complicated case involving the inadvertent delivery of an 8 French sheath across the noncoronary cusp during radiofrequency catheter ablation for left atrial tachycardia originating from the mitral annulus in a patient with prior mitral valve replacement.

  9. Clinical application of percutaneous balloon mitral valvuloplasty in patients with rheumatic mitral stenosis and left atrial thrombi

    International Nuclear Information System (INIS)

    Chen Junzhu; Zhang Furong; Tao Qianmin; Cheng Guanchang; Zheng Liangrong; Zhu Jianhua

    2002-01-01

    Objective: To evaluate safety and effect of percutaneous balloon mitral valvuloplasty (PBMV) for patients with rheumatic mitral stenosis and left atrial thrombi. Methods: PBMV was performed in 27 patients with rheumatic mitral stenosis and left atrial thrombi. 19 cases of left atrial fresh thrombi revealed by trans-esophageal echocardiography (TEE) received warfarin orally for 3-6 months before PBMV. Results: PBMV was successful in all cases of mitral stenosis and left atrial thrombi. Left atrial fresh thrombi was completely resolved in 9 cases and became smaller chronic organized thrombi in 10 cases after warfarin anticoagulation treatment among 19 cases of left atrial fresh thrombi revealed by TEE. In 5 cases of left atrial chronic organized thrombi shown only transthoracic echocardiography and without anticoagulation treatment, one case had cerebral embolism. No complication occurred in other cases. Conclusions: The study showed that patients with rheumatic mitral stenosis and atrial fibrillation should have routine TEE. PBMV for rheumatic mitral stenosis with left atrial thrombi after anticoagulation treatment is safe and effective

  10. Predictors and prognostic value of left atrial remodelling after acute myocardial infarction

    DEFF Research Database (Denmark)

    Kyhl, Kasper; Vejlstrup, Niels; Lønborg, Jacob

    2015-01-01

    PURPOSE: Left atrial (LA) volume is a strong prognostic predictor in patients following ST-segment elevation myocardial infarction (STEMI). However, the change in LA volume over time (LA remodelling) following STEMI has been scarcely studied. We sought to identify predictors for LA remodelling an...

  11. Changes in left atrial deformation in hypertrophic cardiomyopathy: Evaluation by vector velocity imaging

    Directory of Open Access Journals (Sweden)

    Hala Mahfouz Badran

    2012-12-01

    Full Text Available Objectives: Hypertrophic cardiomyopathy (HCM represents a generalized myopathic process affecting both ventricular and atrial myocardium. We assessed the global and regional left atrial (LA function and its relation to left ventricular (LV mechanics and clinical status in patients with HCM using Vector Velocity Imaging (VVI. Methods: VVI of the LA and LV was acquired from apical four- and two-chamber views of 108 HCM patients (age 40±19years, 56.5% men and 33 healthy subjects, all had normal LV systolic function. The LA subendocardium was traced to obtain atrial volumes, ejection fraction, velocities, and strain (ɛ/strain rate (SR measurements. Results: Left atrial reservoir (ɛsys,SRsys and conduit (early diastolic SRe function were significantly reduced in HCM compared to controls (P-1.8s-1 was 81% sensitive and 30% specific, SRa>-1.5s-1 was 73% sensitive and 40% specific. By multivariate analysis global LVɛsys and LV septal thickness are independent predictors for LAɛsys, while end systolic diameter is the only independent predictor for SRsys, P<.001. Conclusion: Left atrial reservoir and conduit function as measured by VVI were significantly impaired while contractile function was preserved among HCM patients. Left atrial deformation was greatly influenced by LV mechanics and correlated to severity of phenotype.

  12. Changes in left atrial deformation in hypertrophic cardiomyopathy: Evaluation by vector velocity imaging

    Science.gov (United States)

    Badran, Hala Mahfouz; Soltan, Ghada; Hassan, Hesham; Nazmy, Ahmed; Faheem, Naglaa; Saadan, Haythem; Yacoub, Magdi H.

    2012-01-01

    Abstract: Objectives: Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. We assessed the global and regional left atrial (LA) function and its relation to left ventricular (LV) mechanics and clinical status in patients with HCM using Vector Velocity Imaging (VVI). Methods: VVI of the LA and LV was acquired from apical four- and two-chamber views of 108 HCM patients (age 40 ± 19years, 56.5% men) and 33 healthy subjects, all had normal LV systolic function. The LA subendocardium was traced to obtain atrial volumes, ejection fraction, velocities, and strain (ϵ)/strain rate (SR) measurements. Results: Left atrial reservoir (ϵsys,SRsys) and conduit (early diastolic SRe) function were significantly reduced in HCM compared to controls (P  − 1.8s− 1 was 81% sensitive and 30% specific, SRa> − 1.5s− 1 was 73% sensitive and 40% specific. By multivariate analysis global LVϵsys and LV septal thickness are independent predictors for LAϵsys, while end systolic diameter is the only independent predictor for SRsys, P < .001. Conclusion: Left atrial reservoir and conduit function as measured by VVI were significantly impaired while contractile function was preserved among HCM patients. Left atrial deformation was greatly influenced by LV mechanics and correlated to severity of phenotype. PMID:24688992

  13. Incisional left atrial isolation for ablation of atrial fibrillation in mitral valve surgery.

    Science.gov (United States)

    Graffigna, Angelo; Branzoli, Stefano; Sinelli, Stefano; Vigano, Mario

    2009-01-01

    The renewed interest in surgical techniques for atrial fibrillation (AF) limited to the left atrium has risen the importance of the original technique of left atrial isolation by means of surgical incision. Transmurality of lesions and cost containment are strong elements to be appreciated in this technique.

  14. Mapping of the left-sided phrenic nerve course in patients undergoing left atrial catheter ablations.

    Science.gov (United States)

    Huemer, Martin; Wutzler, Alexander; Parwani, Abdul S; Attanasio, Philipp; Haverkamp, Wilhelm; Boldt, Leif-Hendrik

    2014-09-01

    Catheter ablation of atrial fibrillation has been associated with left-sided phrenic nerve palsy. Knowledge of the individual left phrenic nerve course therefore is essential to prevent nerve injury. The aim of this study was to test the feasibility of an intraprocedural pace mapping and reconstruction of the left phrenic nerve course and to characterize which anatomical areas are affected. In patients undergoing left atrial catheter ablation, a three-dimensional map of the left atrial anatomical structures was created. The left-sided phrenic nerve course was determined by high-output pace mapping and reconstructed in the map. In this study, 40 patients with atrial fibrillation or atrial tachycardias were included. Left phrenic nerve capture was observed in 23 (57.5%) patients. Phrenic nerve was captured in 22 (55%) patients inside the left atrial appendage, in 22 (55%) in distal parts, in 21 (53%) in medial parts, and in two (5%) in ostial parts of the appendage. In three (7.5%) patients, capture was found in the distal coronary sinus and in one (2.5%) patient in the left atrium near the left atrial appendage ostium. Ablation target was changed due to direct spatial relationship to the phrenic nerve in three (7.5%) patients. No phrenic nerve palsy was observed. Left-sided phrenic nerve capture was found inside and around the left atrial appendage in the majority of patients and additionally in the distal coronary sinus. Phrenic nerve mapping and reconstruction can easily be performed and should be considered prior catheter ablations in potential affected areas. ©2014 Wiley Periodicals, Inc.

  15. Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke.

    Science.gov (United States)

    Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong

    2017-10-01

    Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.

  16. [Left atrial function and left atrial appendage flow velocity in hypertrophic cardiomyopathy: comparison of patients with and without paroxysmal atrial fibrillation].

    Science.gov (United States)

    Akasaka, K; Kawashima, E; Shiokoshi, T; Ishii, Y; Hasebe, N; Kikuchi, K

    1998-07-01

    The involvement of left atrial (LA) appendage flow velocity in reduced left atrial function was investigated in 24 patients with hypertrophic cardiomyopathy, who retained sinus rhythm at the examination. Patients were divided into 11 with a history of paroxysmal atrial fibrillation [PAf(+)] and 13 without such history [PAf(-)]. Transthoracic echocardiography was performed to evaluate LA fractional shortening (LA%FS) and mean velocity of circumferential LA fiber shortening (LAmVcf), as contractile functions of the left atrium at the phase of active atrial contraction. Transesophageal echocardiographic Doppler examination was performed in all patients to measure the LA appendage velocity. In all patients, significant positive correlations were observed between the LA appendage velocity and LA%FS (r = 0.50, p fibrillation were significantly lower than in those without (0.84 +/- 0.15 vs 1.28 +/- 0.37 circ/sec, 44 +/- 12 vs 65 +/- 20 cm/sec, both p fibrillation. These results indicate that there is a close relationship between LA appendage velocity and LA contractile function in patients with hypertrophic cardiomyopathy with paroxysmal atrial fibrilation, and these patients have potential risk of cerebral infarction.

  17. ABO blood groups: A risk factor for left atrial and left atrial appendage thrombogenic milieu in patients with non-valvular atrial fibrillation.

    Science.gov (United States)

    Fu, Yuan; Li, Kuibao; Yang, Xinchun

    2017-08-01

    Previous studies have identified ABO blood groups as predictors of thromboembolic diseases. In patients with atrial fibrillation (AF), however, potential association between ABO blood groups and the risk of left atrial (LA) and/or left atrial appendage (LAA) thrombogenic milieu (TM) has not been established. This is a retrospective case-control study that included 125 consecutive patients with non-valvular atrial fibrillation (NVAF) plus TM, as evidenced by transesophageal echocardiography (TEE) during a period from1 January 2010 to 31 December 2016. The controls were selected randomly from 1072 NVAF without TM at a 1:2 ratio. Potential association between ABO blood groups and TM was analyzed using multivariate logistic regression analysis. The risk of TM was higher in patients with blood group A (33.6% vs. 20.2% in non-A blood groups, P=0.005). After adjusting for age, sex, oral anticoagulant use, AF type and duration, and relevant functional measures (e.g., NT-pro BNP level, left atrium diameter, and left ventricular ejection fraction), blood group A remained associated with an increased risk of TM (OR=2.99, 95% CI 1.4-6.388, P=0.005). Blood group A is an independent risk factor for TM in NVAF patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Detection and evaluation of left atrial myxoma by gated radionuclide imaging

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Adachi, Haruhiko; Nakagawa, Hiroaki

    1985-01-01

    Radionuclide imaging plays an important role in diagnosising left atrial myxoma (LAM). We discussed diagnostic value of Fourier analysis with phase image and evaluated left ventricular filling function using indices such as 1/3 Filling Fraction, Rapid Filling Fraction and Peak Filling Rate derived from left ventricular volume curve. Equillibrium radionuclide angiocardiography was performed in 6 LAM patients. Phase delay in the basal portion of the left ventricle was shown in 5 of 6 LAM patients, and standard deviation of left ventricular phase was larger than these of controls. Left ventricular filling disturbance was suggested in 5 of 6 LAM patients. After surgical remove of myxoma phase delay was disappeared and standard deviation was normalized. And left ventricular filling was improved. We concluded that the phase image of Fourier analysis revealed a left atrial mass prolapsing in the left ventricule during the diastole, and that diastolic indices were useful for left ventricular filling disturbance due to LAM. (author)

  19. Left atrial appendage occlusion for stroke prevention in atrial fibrillation in Europe

    DEFF Research Database (Denmark)

    Lip, Gregory Y.H.; Dagres, Nikolaos; Proclemer, Alessandro

    2013-01-01

    The purpose of this EP wire survey was to assess clinical practice in relation to the use of left atrial appendage occlusion (LAAO) devices for stroke prevention in atrial fibrillation (AF) among members of the European Heart Rhythm Association research network. The average number of performed LA...... are most often performed by interventional cardiologists. Experience varied widely, and this was reflected in the wide range of thromboembolic and procedural (tamponade, bleeding) complications reported by the respondents to this EP wire survey....

  20. Rare Chronic Gastric Volvulus Associated with Left Atrial and Mediastinal Compression

    OpenAIRE

    Shriki, Jabi E.; Nguyen, Khanh; Rozo, Juan Carlos; Reul, George J.; Mortazavi, Ali

    2002-01-01

    We report a case of chronic gastric volvulus associated with left atrial compression in a 75-year-old woman who presented with chest pain, shortness of breath, and hypotension after elective hemiarthroplasty of the left hip. The patient's medical history included a paraesophageal hernia and gastric volvulus diagnosed in 1997 but left untreated. The present diagnosis of gastric volvulus was made on the basis of a chest radiograph and subsequent computed tomography. Echocardiography showed the ...

  1. A case of anemia with left atrial myxoma suspected as late effect of an atomic bomb

    International Nuclear Information System (INIS)

    Sugahara, Hiroko; Aosaki, Noboru; Kurita, Akira

    1980-01-01

    A 43 years old housewife with a history of exposure to an atomic bomb at 8 years old, recently developed anemia and palpitation. The laboratory data showed accelerated ESR, anemia (Hb 10.0 g/dl), and hyper γ-globulinemia. Despite the suspicion of late effect of atomic radiation, further examinations confirmed the diagnosis of left atrial myxoma. The echocardiographic studies revealed the decrease of diastolic descent rate, and multiple echos reflected from the tumor within the mitral orifice during diastole. Cardiac catheterization demonstrated remarkably high value of PCWP (V-wave 38 mmHg) and space filling defect moving from left atrium to left ventricle by cineangiography. Phonecardiographic studies were similar to mitral stenosis. After left atrial myxoma was removed, her symptoms and laboratory data including all noninvasive findings were improved. Therefore we suspected that her symptoms was related with left atrial myxoma rather than the late effect of atomic bomb exposure. We have discussed its significance and usefulness of noninvasive diagnostic approaches as well as whole body computed tomography in heart tumor. (author)

  2. Left atrial size and function as predictors of new-onset of atrial fibrillation in patients with asymptomatic aortic stenosis

    DEFF Research Database (Denmark)

    Bang, Casper Niels Furbo; Dalsgaard, Morten; Greve, Anders

    2013-01-01

    Left atrial (LA) size and function change with chronically increased left ventricular (LV) filling pressures. It remains unclear whether these variations in LA parameters can predict new-onset atrial fibrillation (AF) in asymptomatic patients with aortic stenosis (AS).......Left atrial (LA) size and function change with chronically increased left ventricular (LV) filling pressures. It remains unclear whether these variations in LA parameters can predict new-onset atrial fibrillation (AF) in asymptomatic patients with aortic stenosis (AS)....

  3. Left Atrial Enlargement in Young High-Level Endurance Athletes – Another Sign of Athlete’s Heart?

    Directory of Open Access Journals (Sweden)

    Król Wojciech

    2016-12-01

    Full Text Available Enlargement of the left atrium is perceived as a part of athlete’s heart syndrome, despite the lack of evidence. So far, left atrial size has not been assessed in the context of exercise capacity. The hypothesis of the present study was that LA enlargement in athletes was physiological and fitness-related condition. In addition, we tried to assess the feasibility and normal values of left atrial strain parameters and their relationship with other signs of athlete’s heart. The study group consisted of 114 international-level rowers (17.5 ± 1.5 years old; 46.5% women. All participants underwent a cardio-pulmonary exercise test and resting transthoracic echocardiography. Beside standard echocardiographic measurements, two dimensional speckle tracking echocardiography was used to assess average peak atrial longitudinal strain, peak atrial contraction strain and early left atrial diastolic longitudinal strain. Mild, moderate and severe left atrial enlargement was present in 27.2°%, 11.4% and 4.4% athletes, respectively. There were no significant differences between subgroups with different range of left atrial enlargement in any of echocardiographic parameters of the left ventricle diastolic function, filling pressure or hypertrophy. A significant correlation was found between the left atrial volume index and maximal aerobic capacity (R > 0.3; p < 0.001. Left atrial strain parameters were independent of atrial size, left ventricle hypertrophy and left ventricle filling pressure. Decreased peak atrial longitudinal strain was observed in 4 individuals (3.5%. We concluded that LA enlargement was common in healthy, young athletes participating in endurance sport disciplines with a high level of static exertion and was strictly correlated with exercise capacity, therefore, could be perceived as another sign of athlete’s heart.

  4. Epidemiological study of dilated cardiomyopathy from eastern India with special reference to left atrial size

    Directory of Open Access Journals (Sweden)

    Rudrajit Paul, Saumen Nandi, Pradip K Sinha

    2014-07-01

    Full Text Available Dilated cardiomyopathy (DCM is a common cause of emergency visit in our country. The disease is often misdiagnosed and mistreated. There are very few studies on DCM from India. We undertook a small study on DCM patients from Eastern India to find the demographic and echocardiographic characteristics. Patients and methods: We under took this study in a tertiary care Medical College of Eastern India. All patients coming to the emergency with dyspnea were evaluated for cardiac dysfunction. Emergency echocardiography was done to diagnose dilated cardiomyopathy. Patients with DCM were then evaluated as per protocol. After stabilization, echocardiography was repeated to note the study parameters like left atrial diameter. Standard statistical tests were used. Results: we had a total of 70 patients in our study with a male: female ratio of 43:27. Most patients were aged over 40 years. Patients with COPD, history of radiation, malignancy or drug abuse were excluded. Most patients (47% were on NYHA stage 3 at the time of presentation. In our patient cohort, 24% were alcoholic and 46% were smokers. Atrial fibrillation was present in 15.7% of the patients and right and left bundle branch block had been present in 8 and 15 patients respectively. In echocardiography, increased left atrial (LA size (>40 mm was found in 45 patients. Many patients had valvular regurgitation, mitral, aortic or tricuspid. LA size was positively correlated with left ventricular systolic diameter (r=0.403 and negatively correlated with ejection fraction (r= -0.23. Analysis and conclusion: different ECG abnormalities like bundle branch block and arrhythmias like atrial fibrillation are quite common in DCM. In echocardiography, left atrial size is an important prognostic marker and correlates with left ventricular function.

  5. Outcomes following the Kawashima procedure for single-ventricle palliation in left atrial isomerism.

    Science.gov (United States)

    Vollebregt, Anne; Pushparajah, Kuberan; Rizvi, Maleeha; Hoschtitzky, Andreas; Anderson, David; Austin, Conal; Tibby, Shane M; Simpson, John

    2012-03-01

    Patients with left atrial isomerism and interrupted inferior vena cava palliated with a superior cavopulmonary connection or Kawashima procedure (KP) have a high incidence of developing pulmonary arteriovenous malformations. The necessity for hepatic vein redirection (HVR) and its timing remains a controversy. We aimed to assess the clinical outcome of patients with left atrial isomerism following a KP. The main end points were death, requirement for HVR and the impact of HVR on oxygen saturation. Retrospective review of 21 patients with a diagnosis of left atrial isomerism, interruption of the inferior vena cava and single-ventricle physiology managed with a KP at a single centre between January 1990 and March 2010. Twenty-one patients had a KP, with 12 subsequently undergoing HVR. There was relatively a constant monthly decrement in the proportion of patients who were free from death or HVR up until 60 months following the KP, with a dramatic increase in the hazard after this time. The Cox proportional hazards regression model demonstrated a reduced early risk for HVR or death in patients who underwent pulmonary artery banding versus arterial shunt as the primary procedure (hazard ratio: 0.10; P = 0.01), and an increased risk with bilateral superior vena cavas (SVCs) (hazard ratio: 3.4; P = 0.04) and age at KP (hazard ratio: 1.02 per month increase in age at KP; P = 0.02). HVR mortality was relatively high with 3 of 12 patients dying in the early postoperative period with profound cyanosis. The timing of HVR after the KP did not influence the postoperative rate of increase in oxygen saturation. These findings confirm that the majority of patients who undergo a KP will require HVR. Patients who are older at the time of the KP or having an initial arterial shunt or bilateral SVCs are at higher risk of HVR or death. The relatively high mortality at HVR was characterized by severe postoperative cyanosis.

  6. Left atrial mass 16 years after radiation therapy for mediastinal neuroblastoma

    International Nuclear Information System (INIS)

    Ensing, G.J.; Driscoll, D.J.; Smithson, W.A.

    1987-01-01

    Tumors involving the heart during childhood are rare. However, neuroblastoma, a common pediatric malignancy, has been described to involve the cardiovascular system in 3%-12% of patients dying with this tumor. Rarely is such involvement diagnosed ante mortem and never, to our knowledge, has a benign cardiac tumor been reported to present in childhood after successful eradication of neuroblastoma. We describe the identification and surgical resection of a nodular, hypertrophied, calcified, pedunculated left atrial mass in a 16-year-old boy who was complaining of exercise-associated presyncope and headaches 16 years after irradiation and chemotherapy for mediastinal neuroblastoma

  7. Case Report of a Left Atrial Myxoma Associated with Carney%u2019s Syndrome

    Directory of Open Access Journals (Sweden)

    Anil Ozen

    2016-05-01

    Full Text Available Primary cardiac neoplasms are very rare as compared to metastatic tumors. 70% to 80% of them are benign myxomas. Complications of myxomas include cyst and microabscess formation, embolization, syncope and sudden death. Rarely, cardiac myxomas are associated with primary nodular adrenal cortical disease, mammary fibroadenomas, testicular tumors or pitiutary adenomas with gigantism or acromegaly known as Carney%u2019s syndrome. We present a patient with a left atrial myxoma who underwent reoperation associated with Carney%u2019s syndrome.

  8. Left Atrial Linear Ablation of Paroxysmal Atrial Fibrillation Guided by Three-dimensional Electroanatomical System

    DEFF Research Database (Denmark)

    Zhang, Dai-Fu; Li, Ying; Qi, Wei-Gang

    2005-01-01

    Objective To investigate the safety and efficacy of Left atrial linear ablation of paroxysmal atrial fibrillation guided by three-dimensional electroanatomical system. Methods 29 patients with paroxysmal atrial fibrillation in this study. A nonfluoroscopic mapping system was used to generate a 3D...... electroanatomic LA mapping, and all pulmonary vein ostia were marked under the help of pulmonary veins angiography on the 3D map. Radiofrequency (RF) energy was delivered to create continuous linear lesions encircling the pulmonary veins, it was delivered with a target temperature of 43¿, a maximal power limit...

  9. Left atrial appendages from adult hearts contain a reservoir of diverse cardiac progenitor cells.

    Directory of Open Access Journals (Sweden)

    Jussi V Leinonen

    Full Text Available There is strong evidence supporting the claim that endogenous cardiac progenitor cells (CPCs are key players in cardiac regeneration, but the anatomic source and phenotype of the master cardiac progenitors remains uncertain. Our aim was to investigate the different cardiac stem cell populations in the left atrial appendage (LAA and their fates.We investigated the CPC content and profile of adult murine LAAs using immunohistochemistry and flow cytometry. We demonstrate that the LAA contains a large number of CPCs relative to other areas of the heart, representing over 20% of the total cell number. We grew two distinct CPC populations from the LAA by varying the degree of proteolysis. These differed by their histological location, surface marker profiles and growth dynamics. Specifically, CD45(pos cells grew with milder proteolysis, while CD45(neg cells grew mainly with more intense proteolysis. Both cell types could be induced to differentiate into cells with cardiomyocyte markers and organelles, albeit by different protocols. Many CD45(pos cells expressed CD45 initially and rapidly lost its expression while differentiating.Our results demonstrate that the left atrial appendage plays a role as a reservoir of multiple types of progenitor cells in murine adult hearts. Two different types of CPCs were isolated, differing in their epicardial-myocardial localization. Considering studies demonstrating layer-specific origins of different cardiac progenitor cells, our findings may shed light on possible pathways to study and utilize the diversity of endogenous progenitor cells in the adult heart.

  10. Atorvastatin can ameliorate left atrial stunning induced by radiofrequency ablation for atrial fibrillation.

    Science.gov (United States)

    Xie, Ruiqin; Yang, Yingtao; Cui, Wei; Yin, Hongning; Zheng, Hongmei; Zhang, Jidong; You, Ling

    2017-09-01

    The objective of this study was to study the functional changes of the left atrium after radiofrequency ablation treatment for atrial fibrillation and the therapeutic effect of atorvastatin. Fifty-eight patients undergoing radiofrequency ablation for atrial fibrillation were randomly divided into non-atorvastatin group and atorvastatin group. Patients in the atorvastatin group were treated with atorvastatin 20 mg p.o. per night in addition to the conventional treatment of atrial fibrillation; patients in the non-atorvastatin group received conventional treatment of atrial fibrillation only. Echocardiography was performed before radiofrequency ablation operation and 1 week, 2 weeks, 3 weeks, and 4 weeks after operation. Two-dimensional ultrasound speckle tracking imaging system was used to measure the structural indexes of the left atrium. Results indicated that there was no significant change for indexes representing the structural status of the left atrium within a month after radiofrequency ablation (P > 0.05); however, there were significant changes for indexes representing the functional status of the left atrium. There were also significant changes in indexes reflecting left atrial strain status: the S and SRs of atorvastatin group were higher than those of non-atorvastatin group (P atorvastatin could improve left atrial function and shorten the duration of atrial stunning after radiofrequency ablation of atrial fibrillation.

  11. Long-term survival of quiescent left atrial myxoma in an elderly patient.

    Science.gov (United States)

    Kay, Jay F L; Chow, Wing Hing

    2002-01-01

    Left atrial myxoma, if left untreated, is inexorably progressive and usually fatal. The classical management of this disease is prompt surgical removal. However, there may be exceptions to this traditional dogma. The authors report an 85-year-old man who presented with features of chronic obstructive airway disease and congestive heart failure 15 years previously. Auscultation of the heart showed a pansystolic murmur. Two-dimensional echocardiography revealed a nonobstructive, calcified, and well circumscribed mass in the left atrium, with a pedicle attached to the interatrial septum. Because the patient refused high-risk cardiac surgery related to his comorbidity, he was managed medically with a bronchodilator, diuretics, and digoxin. There have been no features of embolism or intracardiac obstruction, and serial echocardiography demonstrates no disease progression over this long period of time. This case illustrates that calcified left atrial myxoma may exhibit a quiescent phase. Tumor calcification, slow growth potential, and the absence of intracardiac obstruction may correlate with a better outcome in the elderly patient. (c)2002 CVRR, Inc.

  12. Limb ischemia, an alarm signal to a thromboembolic cascade - renal infarction and nephrectomy followed by surgical suppression of the left atrial appendage.

    Science.gov (United States)

    Caraşca, Cosmin; Borda, Angela; Incze, Alexandru; Caraşca, Emilian; Frigy, Attila; Suciu, HoraŢiu

    2016-01-01

    We present the case of a 55-year-old male with mild hypertension and brief episodes of paroxysmal self-limiting atrial fibrillation (AF) since 2010. Despite a small cardioembolic risk score, CHA2DS2-Vasc=1 (Congestive heart failure, Hypertension, Age=75, Diabetes melitus, prior Stroke), the patient is effectively anticoagulated using acenocumarol. In December 2014, he showed signs of plantar transitory ischemia, for which he did not address the doctor. In early January 2015, he urgently presented at the hospital with left renal pain, caused by a renal infarction, diagnosed by computed tomography (CT) angiography. Left nephrectomy was performed with pathological confirmation. He was discharged with effective anticoagulation treatment. Within the next two weeks, he suffered a transitory ischemic event and a stroke, associated with right sided hemiparesis. On admission, AF was found and converted to sinus rhythm with effective anticoagulation - international normalized ratio (INR) of 2.12. Transthoracic echocardiography detected no pathological findings. Transesophageal echocardiography showed an expended left atrial appendage (LAA) with a slow blood flow (0.2 m÷s) and spontaneous echocontrast. Considering these clinical circumstances, surgical LAA suppression was decided on as a last therapeutic resort. Postoperative evolution was favorable; the patient is still free of ischemic events, one year post-intervention. Some morphological and hemodynamic characteristics of LAA may add additional thromboembolic risk factors, not included in scores. Removing them by surgical LAA suppression may decrease the risk of cardioembolic events. Intraoperative presence of thrombus makes it an indisputable proof.

  13. Rationale and Design of the Reduce Elevated Left Atrial Pressure in Patients With Heart Failure (Reduce LAP-HF) Trial

    DEFF Research Database (Denmark)

    Hasenfuss, Gerd; Gustafsson, Finn; Kaye, David

    2015-01-01

    OBJECTIVE: Heart failure with preserved ejection fraction (HFpEF) is characterized by elevated left atrial pressure during rest and/or exercise. The Reduce LAP-HF (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) trial will evaluate the safety and performance of the Interatrial...... Shunt Device (IASD) System II, designed to directly reduce elevated left atrial pressure, in patients with HFpEF. METHODS: The Reduce LAP-HF Trial is a prospective, nonrandomized, open-label trial to evaluate a novel device that creates a small permanent shunt at the level of the atria. A minimum of 60...... patients with ejection fraction ≥40% and New York Heart Association functional class III or IV heart failure with a pulmonary capillary wedge pressure (PCWP) ≥15 mm Hg at rest or ≥25 mm Hg during supine bike exercise will be implanted with an IASD System II, and followed for 6 months to assess the primary...

  14. Clinical impact of quantitative left atrial vortex flow analysis in patients with atrial fibrillation: a comparison with invasive left atrial voltage mapping.

    Science.gov (United States)

    Lee, Jung Myung; Hong, Geu-Ru; Pak, Hui-Nam; Shim, Chi Young; Houle, Helene; Vannan, Mani A; Kim, Minji; Chung, Namsik

    2015-08-01

    Recently, left atrial (LA) vortex flow analysis using contrast transesophageal echocardiography (TEE) has been shown to be feasible and has demonstrated significant differences in vortex flow morphology and pulsatility between normal subjects and patients with atrial fibrillation (AF). However, the relationship between LA vortex flow and electrophysiological properties and the clinical significance of LA vortex flow are unknown. The aims of this study were (1) to compare LA vortex flow parameters with LA voltage and (2) to assess the predictive value of LA vortex flow parameters for the recurrence of AF after radiofrequency catheter ablation (RFCA). Thirty-nine patients with symptomatic non-valvular AF underwent contrast TEE before undergoing RFCA for AF. Quantitative LA vortex flow parameters were analyzed by Omega flow (Siemens Medical Solution, Mountain View, CA, USA). The morphology and pulsatility of LA vortex flow were compared with electrophysiologic parameters that were measured invasively. Hemodynamic, electrophysiological, and vortex flow parameters were compared between patients with and without early recurrence of AF after RFCA. Morphologic parameters, including LA vortex depth, length, width, and sphericity index were not associated with LA voltage or hemodynamic parameters. The relative strength (RS), which represents the pulsatility power of LA, was positively correlated with LA voltage (R = 0.53, p = 0.01) and LA appendage flow velocity (R = 0.73, p vortex flow analysis, especially RS, correlated well with LA voltage. Decreased pulsatility strength in the LA was associated with recurrent AF. LA vortex may have incremental value in predicting the recurrence of AF.

  15. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    International Nuclear Information System (INIS)

    Wolf, Florian; Ourednicek, Petr; Loewe, Christian; Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne; Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes; Feuchtner, Gudrun M.

    2010-01-01

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  16. Atrial conduction times and left atrial mechanical functions and their relation with diastolic function in prediabetic patients.

    Science.gov (United States)

    Gudul, Naile Eris; Karabag, Turgut; Sayin, Muhammet Rasit; Bayraktaroglu, Taner; Aydin, Mustafa

    2017-03-01

    The aim of this study was to investigate atrial conduction times and left atrial mechanical functions, the noninvasive predictors of atrial fibrillation, in prediabetic patients with impaired fasting glucose (IFG) and impaired glucose tolerance (IGT). Study included 59 patients (23 males, 36 females; mean age 52.5 ± 10.6 years) diagnosed with IFG or IGT by the American Diabetes Association criteria, and 43 healthy adults (22 males, 21 females; mean age 48.5 ± 12.1 years). Conventional and tissue Doppler echocardiography were performed. The electromechanical delay parameters were measured from the onset of the P wave on the surface electrocardiogram to the onset of the atrial systolic wave on tissue Doppler imaging from septum, lateral, and right ventricular annuli. The left atrial volumes were calculated by the disk method. Left atrial mechanical functions were calculated. The mitral E/A and E'/A' ratios measured from the lateral and septal annuli were significantly lower in the prediabetics compared to the controls. The interatrial and left atrial electromechanical delay were significantly longer in prediabetic group compared to the controls. Left atrial active emptying volume (LAAEV) and fraction (LAAEF) were significantly higher in the prediabetics than the controls. LAAEV and LAAEF were significantly correlated with E/A, lateral and septal E'/A'. In the prediabetic patients, the atrial conduction times and P wave dispersion on surface electrocardiographic were longer before the development of overt diabetes. In addition, the left atrial mechanical functions were impaired secondary to a deterioration in the diastolic functions in the prediabetic patients.

  17. Left atrial appendage closure: Six reasons why I wouldn't choose a percutaneous closure for my appendage.

    Science.gov (United States)

    Ferlini, Marco; Rossini, Roberta

    2018-01-15

    Left atrial appendage has been shown as a primary source of thrombi in patients with non-valvular atrial fibrillation (AF). Non vitamin k oral anticoagulants (NOAC) have been shown to be safe and effective in the prevention of embolic complications. Current guidelines on AF state that percutaneous left atrial appendage closure (LAAC) might be considered in patients with contraindication to long term oral anticoagulant therapy (OAC). An overview of the main trials on NOAC and LAAC is provided. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.a [Department of Radiology, Medical University of Vienna, Vienna (Austria); Ourednicek, Petr [Philips Medical Systems, Prague (Czech Republic); Loewe, Christian [Department of Radiology, Medical University of Vienna, Vienna (Austria); Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne [Department of Cardiology, Medical University of Vienna, Vienna (Austria); Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes [Department of Radiology, Medical University of Vienna, Vienna (Austria); Feuchtner, Gudrun M. [Department of Radiology, Innsbruck Medical University, Innsbruck (Austria); Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2010-08-15

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  19. Left atrial volume and function in dogs with naturally occurring myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Höllmer, M.; Willesen, J. L.; Tolver, A.

    2017-01-01

    stroke volume increased, whereas LA reservoir and contractile function decreased with increasing disease severity. A maximal LA volume heart failure in dogs with chronic MMVD with a sensitivity of 96% and a specificity of 100......%. An active LA emptying fraction heart failure in dogs with chronic MMVD with a sensitivity of 77% and a specificity of 89% and a sensitivity of 82% and a specificity of 82%, respectively. CONCLUSION: Dogs with MMVD appear to have larger LA...... of cardiac compensation. Left atrial function in dogs with naturally occurring MMVD remains largely unexplored. The objective of this study was to evaluate LA volume and function in dogs with naturally occurring MMVD. ANIMALS: This prospective study included 205 client-owned dogs of different breeds, 114...

  20. Catheter Ablation of Ectopic Atrial Tachycardia Originating from the Left Atrial Appendage using CARTOMERGE® System

    Directory of Open Access Journals (Sweden)

    Masahiko Goya, MD

    2008-01-01

    Full Text Available A 70-year-old woman was referred because of drug resistant and daily incessant palpitation attack. She had undergone two previous unsuccessful radiofrequency catheter ablations at another hospital. The physical examination, chest X-ray, and echocardiogram were all normal. The 12-lead ECG during tachycardia showed narrow QRS, short PR tachycardia and negative polarity of the P wave in leads I and aVL (Fig. 1A. The ECG monitor showed incessant tachycardia with warming-up phenomenon. Three dimensional electroanatomical map integrated with CT imaging (CARTOMERGE®, Biosense Webster Inc. clearly revealed the radial activation pattern originating from the basalo-postero-inferior aspect of the left atrial appendage. Radiofrequency energy application at this site eliminated tachycardia permanently.

  1. Left Atrial Appendage Closure in Atrial Fibrillation: A World without Anticoagulation?

    Directory of Open Access Journals (Sweden)

    Tahmeed Contractor

    2011-01-01

    Full Text Available Atrial Fibrillation (AF is a common arrhythmia with an incidence that is as high as 10% in the elderly population. Given the large proportion of strokes caused by AF as well as the associated morbidity and mortality, reducing stroke burden is the most important part of AF management. While warfarin significantly reduces the risk of AF-related stroke, perceived bleeding risks and compliance limit its widespread use in the high-risk AF population. The left atrial appendage is believed to be the “culprit” for thrombogenesis in nonvalvular AF and is a new therapeutic target for stroke prevention. The purpose of this review is to explore the evolving field of percutaneous LAA occlusion. After briefly highlighting the risk of stroke with AF, problems with warfarin, and the role of the LAA in clot formation, this article discusses the feasibility and efficacy of various devices which have been developed for percutaneous LAA occlusion.

  2. Simulation of left atrial function using a multi-scale model of the cardiovascular system.

    Directory of Open Access Journals (Sweden)

    Antoine Pironet

    Full Text Available During a full cardiac cycle, the left atrium successively behaves as a reservoir, a conduit and a pump. This complex behavior makes it unrealistic to apply the time-varying elastance theory to characterize the left atrium, first, because this theory has known limitations, and second, because it is still uncertain whether the load independence hypothesis holds. In this study, we aim to bypass this uncertainty by relying on another kind of mathematical model of the cardiac chambers. In the present work, we describe both the left atrium and the left ventricle with a multi-scale model. The multi-scale property of this model comes from the fact that pressure inside a cardiac chamber is derived from a model of the sarcomere behavior. Macroscopic model parameters are identified from reference dog hemodynamic data. The multi-scale model of the cardiovascular system including the left atrium is then simulated to show that the physiological roles of the left atrium are correctly reproduced. This include a biphasic pressure wave and an eight-shaped pressure-volume loop. We also test the validity of our model in non basal conditions by reproducing a preload reduction experiment by inferior vena cava occlusion with the model. We compute the variation of eight indices before and after this experiment and obtain the same variation as experimentally observed for seven out of the eight indices. In summary, the multi-scale mathematical model presented in this work is able to correctly account for the three roles of the left atrium and also exhibits a realistic left atrial pressure-volume loop. Furthermore, the model has been previously presented and validated for the left ventricle. This makes it a proper alternative to the time-varying elastance theory if the focus is set on precisely representing the left atrial and left ventricular behaviors.

  3. Rotational Angiography Based Three-Dimensional Left Atrial Reconstruction: A New Approach for Transseptal Puncture.

    Science.gov (United States)

    Koektuerk, Buelent; Yorgun, Hikmet; Koektuerk, Oezlem; Turan, Cem H; Gorr, Eduard; Horlitz, Marc; Turan, Ramazan G

    2016-02-01

    Rotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. We included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). The mean age of the study population was 61 ± 10 years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 ± 825.3 μGym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 ± 5.5 min. TSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure. © 2015 John Wiley & Sons Ltd.

  4. [Left atrial electric isolation in the treatment of atrial fibrillation secondary to rheumatic valvular disease].

    Science.gov (United States)

    Graffigna, A; Pagani, F; Minzioni, G; Salerno, J; Viganò, M

    1992-08-01

    Surgical isolation of the left atrium was performed for the treatment of chronic atrial fibrillation secondary to valvular disease in 100 patients who underwent valve surgery. From May 1989 to September 1991, 62 patients underwent mitral valve surgery (Group I), 19 underwent mitral valve surgery and DeVega tricuspid annuloplasty (Group II), 15 underwent mitral and aortic surgery (Group III), and 4 patients underwent mitral and aortic surgery and DeVega tricuspid annuloplasty (Group IV). Left atrial isolation was performed prolonging the usual left paraseptal atriotomy towards the left fibrous trigone anteriorly, and the postero-medial commissure posteriorly. The incision was conducted a few millimeters apart from the mitral valve annulus, and cryolesion were placed at the edges to ensure complete electrophysiological isolation of the left atrium. Operative mortality accounted for 3 cases (3%). In 79 patients (81.4%) sinus rhythm recovered and persisted until discharge from the hospital. No differences were found between the groups (Group I: 80.7%; Group II: 68.5%; Group III 86.7%, Group IV 75% - p = N.S.). Three cases of late mortality (3.1%) were registered. long-term results showed persistence of SR in 71% of Group I, 61.2% of Group II, 85.8% of Group III, and 100% of Group IV. The unique risk factor for late recurrency of atrial fibrillation was found to be a duration of preoperative AF longer than 6 months. Due to the high success rate in recovering the sinus rhythm, we suggest left atrial isolation in patients with chronic atrial fibrillation undergoing valvular surgery.

  5. Left atrial appendage obliteration in atrial fibrillation patients undergoing bioprosthetic mitral valve replacement.

    Science.gov (United States)

    Min, X P; Zhu, T Y; Han, J; Li, Y; Meng, X

    2016-02-01

    Left atrial appendage (LAA) obliteration is a proven stroke-preventive measure for patients with nonvalvular atrial fibrillation (AF). However, the efficacy of LAA obliteration for patients with AF after bioprosthetic mitral valve replacement (MVR) remains unclear. This study aimed to estimate the efficacy of LAA obliteration in preventing embolism and to investigate the predictors of thromboembolism after bioprosthetic MVR. We retrospectively studied 173 AF subjects with bioprosthetic MVR; among them, 81 subjects underwent LAA obliteration using an endocardial running suture method. The main outcome measure was the occurrence of thrombosis events (TEs). The mean follow-up time was 40 ± 17 months. AF rhythm was observed in 136 patients postoperatively. The incidence rate of TEs was 13.97 % for postoperative AF subjects; a dilated left atrium (LA; > 49.5 mm) was identified as an independent risk factor of TEs (OR = 10.619, 95 % CI = 2.754-40.94, p = 0.001). For postoperative AF patients with or without LAA, the incidence rate of TEs was 15.8 % (9/57) and 12.7 % (10/79; p = 0.603), respectively. The incidence rate of TEs was 2.7 % (1/36) and 4.2 % (2/48) for the subgroup patients with a left atrial diameter of  49.5 mm (p = 0.346). Surgical LAA obliteration in patients with valvular AF undergoing bioprosthetic MVR did not reduce TEs, even when the CHA2DS2-VASc score (a score for estimating the risk of stroke in AF) was ≥ 2 points.

  6. Pulmonary artery-to-left atrial fistula discovered after the closure of atrial septal defect: A rare clinical scenario

    Directory of Open Access Journals (Sweden)

    Akshay Chauhan

    2018-01-01

    Full Text Available A case of the right pulmonary artery-to- left atrial fistula with atrial septal defect (ASD is presented. The fistula was detected after the patient developed desaturation following surgical closure of the ASD. It was managed with a transcatheter (trans-RPA route closure of the fistula using a 12-mm Amplatzer ventricular septal defect closure device.

  7. Does Left Atrial Volume and Pulmonary Venous Anatomy Predict the Outcome of Catheter Ablation of Atrial Fibrillation ?

    NARCIS (Netherlands)

    Hof, Irene; Chilukuri, Karuna; Arbab-Zadeh, Armin; Scherr, Daniel; Dalal, Darshan; Nazarian, Saman; Henrikson, Charles; Spragg, David; Berger, Ronald; Marine, Joseph; Calkins, Hugh

    Introduction: Preprocedural factors may be helpful in selecting patients with atrial fibrillation (AF) for treatment with catheter ablation and in making an assumption regarding their prognosis. The aims of this study were to investigate whether left atrial (LA) volume and pulmonary venous (PV)

  8. Assessment of left atrial volume and function: a comparative study between echocardiography, magnetic resonance imaging and multi slice computed tomography.

    Science.gov (United States)

    Kühl, J Tobias; Lønborg, Jacob; Fuchs, Andreas; Andersen, Mads J; Vejlstrup, Niels; Kelbæk, Henning; Engstrøm, Thomas; Møller, Jacob E; Kofoed, Klaus F

    2012-06-01

    Measurement of left atrial (LA) maximal volume (LA(max)) using two-dimensional transthoracic echocardiography (TTE) provides prognostic information in several cardiac diseases. However, the relationship between LA(max) and LA function is poorly understood and TTE is less well suited for measuring dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir volume) and pump function (left atrial ejection fraction-LAEF) were derived using CMR and MSCT. Left atrial fractional change and left atrial ejection fraction (LAEF) determined with CMR and MSCT were unrelated to LA(max) enlargement by echocardiography (P = NS). There was an overall good agreement between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P fractional change and LAEF is not significantly related to LA(max) measured by TTE. TTE systematically underestimated LA volumes, whereas there are good agreements between MSCT and CMR for volumetric and functional properties.

  9. 5-Year Outcomes After Left Atrial Appendage Closure: From the PREVAIL and PROTECT AF Trials.

    Science.gov (United States)

    Reddy, Vivek Y; Doshi, Shephal K; Kar, Saibal; Gibson, Douglas N; Price, Matthew J; Huber, Kenneth; Horton, Rodney P; Buchbinder, Maurice; Neuzil, Petr; Gordon, Nicole T; Holmes, David R

    2017-12-19

    The PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) trial demonstrated that left atrial appendage closure (LAAC) with the Watchman device (Boston Scientific, St. Paul, Minnesota) was equivalent to warfarin for preventing stroke in atrial fibrillation, but had a high rate of complications. In a second randomized trial, PREVAIL (Evaluation of the WATCHMAN LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy), the complication rate was low. The warfarin cohort experienced an unexpectedly low ischemic stroke rate, rendering the efficacy endpoints inconclusive. However, these outcomes were based on relatively few patients followed for a relatively short time. The final results of the PREVAIL trial, both alone and as part of a patient-level meta-analysis with the PROTECT AF trial, are reported with patients in both trials followed for 5 years. PREVAIL and PROTECT AF are prospective randomized clinical trials with patients randomized 2:1 to LAAC or warfarin; together, they enrolled 1,114 patients for 4,343 patient-years. Analyses are by intention-to-treat, and rates are events per 100 patient-years. For the PREVAIL trial, the first composite coprimary endpoint of stroke, systemic embolism (SE), or cardiovascular/unexplained death did not achieve noninferiority (posterior probability for noninferiority = 88.4%), whereas the second coprimary endpoint of post-procedure ischemic stroke/SE did achieve noninferiority (posterior probability for noninferiority = 97.5%); the warfarin arm maintained an unusually low ischemic stroke rate (0.73%). In the meta-analysis, the composite endpoint was similar between groups (hazard ratio [HR]: 0.820; p = 0.27), as were all-stroke/SE (HR: 0.961; p = 0.87). The ischemic stroke/SE rate was numerically higher with LAAC, but this difference did not reach statistical significance (HR: 1.71; p = 0.080). However, differences in

  10. Prevention of Cerebral Embolism Progression by Emergency Surgery of the Left Atrial Myxoma

    Directory of Open Access Journals (Sweden)

    Syuichi Tetsuka

    2015-01-01

    Full Text Available A 21-year-old woman developed left hemiparesis during work and was hospitalized. Her National Institutes of Health Stroke Scale score was 4. Hyperintense areas in the left basal ganglia, corona radiata, and cortex of the temporal lobe were found by brain diffusion-weighted magnetic resonance imaging, indicating acute cerebral infarction. Echocardiography showed a giant mass of diameter 7 × 4 cm in the left atrium. Therefore, she was diagnosed with cerebral embolism due to a left atrial myxoma. Currently, thrombolytic therapy may continue to be effective because the embolic source may be composed of tumor tissue itself. In case of atrial myxoma, we considered that the use of tPA as emergency treatment in all patients with infarction by atrial myxoma may be questioned. Thus, cardiac tumor extraction was performed the next day after hospitalization without thrombolytic therapy. The excised myxoma measured 7 × 6 × 4 cm. The patient recovered and her neurological symptoms also improved. Furthermore, her National Institutes of Health Stroke Scale score improved to 0. Thirteen days after admission, the patient was discharged from our hospital. Cardiac myxoma is often associated with a high risk of embolic episodes, which emphasizes the need for prompt surgical excision as soon as the diagnosis is confirmed.

  11. Pulmonary venous flows reflect changes in left atrial hemodynamics during mitral balloon valvotomy.

    Science.gov (United States)

    Yalçin, Fatih; El-Amrousy, Mahmoud; Müderrisoğlu, Haldun; Korkmaz, Mehmet; Flachskampf, Frank; Tuzcu, Murat; Garcia, Mario G; Thomas, James D

    2002-01-01

    Patients with mitral stenosis have usually blunted pulmonary venous (PV) flow, because of decreased mitral valve area and diastolic dysfunction. The authors compared changes in Doppler PV velocities by using transesophageal echocardiography (TEE) against hemodynamics parameters before and after mitral balloon valvotomy to observe relevance of PV velocities and endsystolic left atrial (LA) pressure-volume relationship. In 25 patients (aged 35 +/- 17 years) with mitral stenosis in sinus rhythm, changes in LA pressure and volumes were compared with PV velocities before and after valvotomy. Mitral valve area, mitral gradients, and deceleration time were obtained. Mitral valve area and mitral gradients changed from 1 +/- 0.2 cm2 and 14.6 +/- 5.4 mmHg to 1.9 +/- 0.3 cm2 and 6.3 +/- 1.7 mmHg, respectively (pLA pressure were correlated with changes in S/D (r=0.57, pLA pressure-volume relationship were also correlated with changes in S/D (r=0.52, pLA pressure-volume relationship decreased after mitral balloon valvotomy, as a result of a large decrease in pressure. PV systolic/diastolic (S/D) waves ratio reflects endsystolic LA pressure-volume relationship and may be used as another indicator of successful valvotomy.

  12. Thickening of the left atrial wall shortly after radiofrequency ablation predicts early recurrence of atrial fibrillation

    International Nuclear Information System (INIS)

    Yokokawa, Miki; Koyama, Keiko; Ino, Toshihiko; Naito, Shigeto; Oshima, Shigeru; Taniguchi, Koichi; Tada, Hiroshi

    2010-01-01

    Inflammatory responses following atrial fibrillation (AF) ablation may aggravate arrhythmogenic activity and cause an early recurrence of AF (ERAF). In 56 patients who underwent circumferential pulmonary vein ablation (CPVA) for paroxysmal AF, cardiovascular magnetic resonance imaging (CMRI) was evaluated in 5 subdivided left atrial (LA) regions before the CPVA and at 1 day and 1 month after. At a mean of 7±10 days after the CPVA, 23 patients (41%) developed 1 or more episodes of AF (ERAF group), while 33 patients (59%) remained free from AF during the first month of follow up (no-ERAF group). LA wall thickness increased 1 day after the CPVA in both groups, as demonstrated by high T2-weighted signal. The LA roof thickness and its increase, however, were greater in the ERAF group than in the no-ERAF group (P<0.05). Regions of delayed enhancement (DE) were also frequently detected in both groups, but the total number of DE regions did not differ between the 2 groups. The thickening of the LA wall associated with a high T2-weighted signal resolved within 1 month. No significant difference between the 2 groups was found in any of the CMRI parameters before or 1 month after CPVA. Thickening of the LA roof shortly after CPVA may predict an ERAF. (author)

  13. Comparison of biatrial and left atrial radiofrequency ablation in patients with heart valves diseases

    Directory of Open Access Journals (Sweden)

    А. В. Богачев-прокофьев

    2015-10-01

    Full Text Available We analysed results of left atrial and biatrial anatomic scheme of radiofrequency (RF ablation of the atria in patients with valvular heart. From 2007 to 2011, RF ablation procedure performed 283 patients with atrial fibrillation and heart valve disease. Patients were divided into two groups - group I performed a complete circuit biatrial procedure (procedure maze IV - 131 patients, in group II only ablation of the left atrium -152 patients. Most of the patients had long-term persistent AF. The main problem of early postoperative period is dysfunction of pacemaker complex, which observed in 64.9% and 50.7% patients for group I and II, respectively (p = 0.031. Permanent dysfunction of pacemaker complex required implantation of permanent pacemaker (9.2% and 4.6% of cases for group I and II, respectively, p = 0,023. Predictors of dysfunction of the pacemaker complex were biatrial execution method and duration of AF. Freedom from AF and AT during 36 months after surgery was 80.4% for patients in group I and 78.5% for patients in group II, with no statistically significant difference (log-rank test, p = 0.621. Atrial transport function has not revealed that the active fraction of the right atrium was 29.8% higher than in group II in the early postoperative phase and by 17.9% in the long term, with no difference between groups for the left atrium has been received.

  14. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors

    Directory of Open Access Journals (Sweden)

    Deirdre M Mooney

    2015-10-01

    Full Text Available Heart failure (HF is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  15. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors.

    Science.gov (United States)

    Mooney, Deirdre M; Fung, Erik; Doshi, Rahul N; Shavelle, David M

    2015-01-01

    Heart failure (HF) is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF) can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  16. ST-segment elevation and ventricular fibrillation shortly after transseptal puncture for left atrial catheter ablation

    Directory of Open Access Journals (Sweden)

    Daisuke Ishigaki, MD

    2013-10-01

    Full Text Available A 47-year-old man with drug-resistant paroxysmal atrial fibrillation underwent left atrial (LA catheter ablation. After sheaths were inserted into the LA using the Brockenbrough method, he complained of angina and developed ST-segment elevation in the II, III, aVF, V5, and V6 leads. Ventricular fibrillation (VF occurred followed by ventricular tachycardia. The VF was successfully treated with direct current shock. Coronary angiography with isosorbide dinitrate showed neither spasm nor embolism in the coronary artery. The chest pain disappeared after 6 min with resolution of the ST-segment elevation. A summarized review of ST-segment elevation associated with transseptal puncture disclosed that ST-segment elevation is often found in inferior leads (87.5%, while concomitant bradyarrhythmia has been reported in 43.8% of patients. Our patient is the first recorded case with potentially lethal tachyarrhythmia. Although ST-segment elevation and VF is a rare complication associated with transseptal puncture, awareness of this complication is important.

  17. Effect of Left Ventricular Outflow Tract Obstruction on Left Atrial Mechanics in Hypertrophic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Lynne K. Williams

    2015-01-01

    Full Text Available Left atrial (LA volumes are known to be increased in hypertrophic cardiomyopathy (HCM and are a predictor of adverse outcome. In addition, LA function is impaired and is presumed to be due to left ventricular (LV diastolic dysfunction as a result of hypertrophy and myocardial fibrosis. In the current study, we assess the incremental effect of outflow tract obstruction (and concomitant mitral regurgitation on LA function as assessed by LA strain. Patients with HCM (50 obstructive, 50 nonobstructive were compared to 50 normal controls. A subset of obstructive patients who had undergone septal myectomy was also studied. Utilising feature-tracking software applied to cardiovascular magnetic resonance images, LA volumes and functional parameters were calculated. LA volumes were significantly elevated and LA ejection fraction and strain were significantly reduced in patients with HCM compared with controls and were significantly more affected in patients with obstruction. LA volumes and function were significantly improved after septal myectomy. LVOT obstruction and mitral regurgitation appear to further impair LA mechanics. Septal myectomy results in a significant reduction in LA volumes, paralleled by an improvement in function.

  18. Effects of sedation on echocardiographic variables of left atrial and left ventricular function in healthy cats.

    Science.gov (United States)

    Ward, Jessica L; Schober, Karsten E; Fuentes, Virginia Luis; Bonagura, John D

    2012-10-01

    Although sedation is frequently used to facilitate patient compliance in feline echocardiography, the effects of sedative drugs on echocardiographic variables have been poorly documented. This study investigated the effects of two sedation protocols on echocardiographic indices in healthy cats, with special emphasis on the assessment of left atrial size and function, as well as left ventricular diastolic performance. Seven cats underwent echocardiography (transthoracic two-dimensional, spectral Doppler, color flow Doppler and tissue Doppler imaging) before and after sedation with both acepromazine (0.1 mg/kg IM) and butorphanol (0.25 mg/kg IM), or acepromazine (0.1 mg/kg IM), butorphanol (0.25 mg/kg IM) and ketamine (1.5 mg/kg IV). Heart rate increased significantly following acepromazine/butorphanol/ketamine (mean±SD of increase, 40±26 beats/min) and non-invasive systolic blood pressure decreased significantly following acepromazine/butorphanol (mean±SD of decrease, 12±19 mmHg). The majority of echocardiographic variables were not significantly different after sedation compared with baseline values. Both sedation protocols resulted in mildly decreased left ventricular end-diastolic dimension and mildly increased left ventricular end-diastolic wall thickness. This study therefore failed to demonstrate clinically meaningful effects of these sedation protocols on echocardiographic measurements, suggesting that sedation with acepromazine, butorphanol and/or ketamine can be used to facilitate echocardiography in healthy cats.

  19. Increased pulse pressure is associated with left atrial enlargement in resistant hypertensive patients.

    Science.gov (United States)

    Armario, Pedro; Oliveras, Anna; Hernández-Del-Rey, Raquel; Suárez, Carmen; Martell, Nieves; Ruilope, Luis M; De La Sierra, Alejandro

    2013-02-01

    Resistant hypertension (RH) is frequently associated with a high prevalence of target organ damage, which impairs the prognosis of these patients. Considering cardiac alterations in RH, most attention has been devoted to left ventricular hypertrophy (LVH), but data concerning left atrial enlargement (LAE) is less known. This cross-sectional study assessed the factors associated with LAE, with special focus on blood pressure (BP) estimates obtained by ambulatory blood pressure monitoring (ABPM), in 250 patients with RH, aged 64 ± 11 years. LAE and LVH were observed in 10.0% (95% CI 6.3-13.7) and 57.1% (95% CI 50.8-63.5) of patients, respectively. Compared with patients with normal atrium size, those exhibiting LAE were older, more frequently women, had elevated pulse pressure (PP) measured both at the office and by ABPM, and showed higher prevalence of LVH (83% vs 54%; p = 0.016). In a logistic regression analysis, adjusting for age, gender, body mass index, left ventricular mass index and BP pressure estimates, night-time PP was independently associated with LAE (OR for 5 mmHg = 1.28, 95% CI 1.24-1.32; p = 0.001). In conclusion, besides classical determinants of LAE, such as age and LVH, an elevated night-time PP was independently associated with LAE in patients with RH.

  20. Correlation of right atrial appendage velocity with left atrial appendage velocity and brain natriuretic Peptide.

    Science.gov (United States)

    Kim, Bu-Kyung; Heo, Jung-Ho; Lee, Jae-Woo; Kim, Hyun-Soo; Choi, Byung-Joo; Cha, Tae-Joon

    2012-03-01

    Left atrial appendage (LAA) anatomy and function have been well characterized both in healthy and diseased people, whereas relatively little attention has been focused on the right atrial appendage (RAA). We sought to evaluate RAA flow velocity and to compare these parameters with LAA indices and with a study of biomarkers, such as brain natriuretic peptide, among patients with sinus rhythm (SR) and atrial fibrillation (AF). In a series of 79 consecutive patients referred for transesophageal echocardiography, 43 patients (23 with AF and 20 controls) were evaluated. AF was associated with a decrease in flow velocity for both LAA and RAA [LAA velocity-SR vs. AF: 61 ± 22 vs. 29 ± 18 m/sec (p vs. AF: 46 ± 20 vs. 19 ± 8 m/sec (p brain natriuretic peptide (BNP). AF was associated with decreased RAA and LAA flow velocities. RAA velocity was found to be positively correlated with LAA velocity and negatively correlated with BNP. The plasma BNP concentration may serve as a determinant of LAA and RAA functions.

  1. Relation of Left Atrial Size, Cardiac Morphology, and Clinical Outcome in Asymptomatic Aortic Stenosis

    DEFF Research Database (Denmark)

    Christensen, Nicolaj Lyhne; Dahl, Jordi; Carter-Storch, Rasmus

    2017-01-01

    characterized by higher LV mass index (73 ± 17 g/m² vs. 66 ± 16 g/m² , p=0.03), increased right ventricle (70 ± 14 ml/m² vs. 63 ± 12 ml/m², p=0.01) and LV end-diastolic volume index (84 ± 18 ml/m² vs. 77 ± 16 ml/m², p=0.05), and higher brain natriuretic peptide (BNP). No difference in late enhancement was seen......Left atrial (LA) dilatation in asymptomatic severe aortic stenosis (AS) may be an indicator of advanced disease. The aim was to investigate the association between LA volume index (LAVi) and left ventricular (LV) morphology assessed with cardiac magnetic resonance imaging (cMRI), and to assess...... underwent echocardiography, cMRI, exercise test, and patients were followed for the composite endpoint of death, readmission or aortic valve replacement. AVA index was similar (0.45 ± 0.08 cm² /m² vs. 0.45 ± 0.09 cm², p=0.85) in patients with a dilated and normal LA. On cMRI patients with dilated LA were...

  2. Relationship of carotid arterial functional and structural changes to left atrial volume in untreated hypertension.

    Science.gov (United States)

    Jaroch, Joanna; Rzyczkowska, Barbara; Bociąga, Zbigniew; Vriz, Olga; Driussi, Caterina; Loboz-Rudnicka, Maria; Dudek, Krzysztof; Łoboz-Grudzień, Krystyna

    2016-04-01

    The contribution of arterial functional and structural changes to left ventricular (LV) diastolic dysfunction has been the area of recent research. There are some studies on the relationship between arterial stiffness (a.s.) and left atrial (LA) remodelling as a marker of diastolic burden. Little is known about the association of arterial structural changes and LA remodelling in hypertension (H). The aim of this study was to examine the relationship between carotid a.s. and intima-media thickness (IMT) and LA volume in subjects with H. The study included 245 previously untreated hypertensives (166 women and 79 men, mean age 53.7 ± 11.8 years). Each patient was subjected to echocardiography with measurement of LA volume, evaluation of left ventricular hypertrophy (LVH) and LV systolic/diastolic function indices, integrated assessment of carotid IMT and echo-tracking of a.s. and wave reflection parameters. Univariate regression analysis revealed significant correlations between indexed LA volume and selected clinical characteristics, echocardiographic indices of LVH and LV diastolic/systolic function and a.s./wave reflection parameters. The following parameters were identified as independent determinants of indexed LA volume on multivariate regression analysis: diastolic blood pressure (beta = -0.229, P arterial stiffness but not intima-media thickness and LA volume in patients with untreated hypertension.

  3. Superior transseptal approach to mitral valve is associated with a higher need for pacemaker implantation than the left atrial approach

    DEFF Research Database (Denmark)

    Lukac, Peter; Hjortdal, Vibeke E; Pedersen, Anders K

    2006-01-01

    retrospectively evaluated. The surgeons used either the superior transseptal (group A) or left atrial approach (group B). The risk of pacemaker implantation associated with the superior transseptal approach as compared with the left atrial approach was estimated using the multivariate Cox regression analysis...... to adjust for possible confounders. RESULTS: We included 577 patients, 150 in group A and 427 in group B. Forty-four patients had a pacemaker implanted after the surgery; 17 in group A and 27 in group B (p = 0.010). The superior transseptal approach was an independent risk factor of pacemaker implantation...... in multivariate analysis (hazard ratio 2.2 [1.2 to 4.1], p = 0.014). Nineteen patients had a pacemaker implanted because of sinus node dysfunction; 9 in group A and 10 in group B (p = 0.017). Group A was an independent predictor of pacemaker implantation because of sinus node dysfunction in bivariate analyses...

  4. A Left Atrial Myxoma Case with a History of Stroke on whom a Coronary Bypass Surgery was Performed

    Directory of Open Access Journals (Sweden)

    Cihangir Kaymaz

    2009-12-01

    Full Text Available Cardiac myxomas are the most frequently encountered benign cardiac tumors in adult groups. Patients with myxoma may suffer from variety of clinical features. A patient who had suffered from stroke a yearago came to our hospital with a chest pain complaint. In the echocardiography of the patient suffering from acute coronary syndrome, left ventricular disfunction and left atrial mass was determined. In the coronary angiography, LAD and Cx critical stenosis, and an abnormal feeding artery which roots from Cxperformed was observed. LIMA-AD, Ao-RCA bypass and mass exision withleft atriotomy was made. Cardiac tumor embolism which makes up a rare cause of cerebral embolies should be considered especiallyin patients with sinus rhythm. In the coronary angiography the feeding artery of the myxoma was shown. A patient who has underwent coronary bypass operation and left atrial myxoma exision has beenpresented as a case.

  5. Association Between Left Atrial Compression And Atrial Fibrillation: A Case Presentation And A Short Review Of Literature.

    Science.gov (United States)

    Ahmed, Niloy; Carlos, Morales-Mangual; Moshe, Gunsburg; Yitzhak, Rosen

    2016-01-01

    This case report describes a patient who developed palpitations and chest pain and was found to be in atrial fibrillation, which was likely due to the presence of an extra-cardiac mass. This was compressing the left atrium. The mass was related to small cell carcinoma, which decreased significantly in size after chemotherapy. Resolution of the atrial fibrillation correlated temporally with reduction in the size of the mass and alleviation of the left atrial compression.

  6. Left atrial low-voltage areas predict atrial fibrillation recurrence after catheter ablation in patients with paroxysmal atrial fibrillation.

    Science.gov (United States)

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki

    2018-04-15

    Association between the presence of left atrial low-voltage areas and atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) has been shown mainly in persistent AF patients. We sought to compare the AF recurrence rate in paroxysmal AF patients with and without left atrial low-voltage areas. This prospective observational study included 147 consecutive patients undergoing initial ablation for paroxysmal AF. Voltage mapping was performed after PVI during sinus rhythm, and low-voltage areas were defined as regions where bipolar peak-to-peak voltage was low-voltage areas after PVI were observed in 22 (15%) patients. Patients with low-voltage areas were significantly older (72±6 vs. 66±10, plow-voltage areas than without (36% vs. 6%, pLow-voltage areas were independently associated with AF recurrence even after adjustment for the other related factors (Hazard ratio, 5.89; 95% confidence interval, 2.16 to 16.0, p=0.001). The presence of left atrial low-voltage areas after PVI predicts AF recurrence in patients with paroxysmal AF as well as in patients with persistent AF. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. The left atrio-vertebral ratio. A new simple means for assessing left atrial enlargement on computed tomography

    International Nuclear Information System (INIS)

    Montillet, Marie; Tasu, Jean-Pierre; Baque-Juston, Marie; Bertrand, Sandra; Berthier, Frederic; Zarqane, Naima; Brunner, Philippe

    2018-01-01

    The purpose of this study is to describe a new method to quickly estimate left atrial enlargement (LAE) on Computed Tomography. Left atrial (LA) volume was assessed with a 3D-threshold Hounsfield unit detection technique, including left atrial appendage and excluding pulmonary venous confluence, in 201 patients with ECG-gated 128-slice dual-source CT and indexed to body surface area. LA and vertebral axial diameter and area were measured at the bottom level of the right inferior pulmonary vein ostium. Ratio of LA diameter and surface on vertebra (LAVD and LAVA) were compared to LA volume. In accordance with the literature, a cutoff value of 78 ml/m 2 was chosen for maximal normal LA volume. 18% of LA was enlarged. The best cutoff values for LAE assessment were 2.5 for LAVD (AUC: 0.65; 95% CI: 0.58-0.73; sensitivity: 57%; specificity: 71%), and 3 for LAVA (AUC: 0.78; 95% CI: 0.72-0.84; sensitivity: 67%; specificity: 79%), with higher accuracy for LAVA (P=0.015). Inter-observer and intra-observer variability were either good or excellent for LAVD and LAVA (respective intraclass coefficients: 0.792 and 0.910; 0.912 and 0.937). A left atrium area superior to three times the vertebral area indicates LAE with high specificity. (orig.)

  8. The left atrio-vertebral ratio. A new simple means for assessing left atrial enlargement on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Montillet, Marie; Tasu, Jean-Pierre [Centre Hospitalier Universitaire de Poitiers, Poitiers (France); Baque-Juston, Marie; Bertrand, Sandra; Berthier, Frederic; Zarqane, Naima; Brunner, Philippe [Hopital Princesse Grace, Monaco (Monaco)

    2018-03-15

    The purpose of this study is to describe a new method to quickly estimate left atrial enlargement (LAE) on Computed Tomography. Left atrial (LA) volume was assessed with a 3D-threshold Hounsfield unit detection technique, including left atrial appendage and excluding pulmonary venous confluence, in 201 patients with ECG-gated 128-slice dual-source CT and indexed to body surface area. LA and vertebral axial diameter and area were measured at the bottom level of the right inferior pulmonary vein ostium. Ratio of LA diameter and surface on vertebra (LAVD and LAVA) were compared to LA volume. In accordance with the literature, a cutoff value of 78 ml/m{sup 2} was chosen for maximal normal LA volume. 18% of LA was enlarged. The best cutoff values for LAE assessment were 2.5 for LAVD (AUC: 0.65; 95% CI: 0.58-0.73; sensitivity: 57%; specificity: 71%), and 3 for LAVA (AUC: 0.78; 95% CI: 0.72-0.84; sensitivity: 67%; specificity: 79%), with higher accuracy for LAVA (P=0.015). Inter-observer and intra-observer variability were either good or excellent for LAVD and LAVA (respective intraclass coefficients: 0.792 and 0.910; 0.912 and 0.937). A left atrium area superior to three times the vertebral area indicates LAE with high specificity. (orig.)

  9. Exchanging Catheters Over a Single Transseptal Sheath During Left Atrial Ablation is Associated with a Higher Risk for Silent Cerebral Events

    Directory of Open Access Journals (Sweden)

    Thomas Deneke, MD

    2014-09-01

    Conclusions: Exchanging catheters over a single transseptal access to perform left atrial ablation is associated with a significantly higher incidence of SCE compared to an ablation technique using different transseptal accesses for therapeutic and diagnostic catheters.

  10. Excessive interatrial adiposity is associated with left atrial remodeling, augmented contractile performance in asymptomatic population

    Directory of Open Access Journals (Sweden)

    Yau-Huei Lai

    2016-05-01

    Full Text Available Purpose: Pericardial adipose tissue had been shown to exert local effects on adjacent cardiac structures. Data regarding the mechanistic link between such measures and left atrial (LA structural/functional remodeling, a clinical hallmark of early stage heart failure (HF and atrial fibrillation (AF incidence, in asymptomatic population remain largely unexplored. Methods: This retrospective analysis includes 356 subjects free from significant valvular disorders, atrial fibrillation, or clinical HF. Regional adipose tissue including pericardial and periaortic fat volumes, interatrial septal (IAS, and left atrioventricular groove (AVG fat thickness were all measured by multidetector computed tomography (MDCT (Aquarius 3D Workstation, TeraRecon, San Mateo, CA, USA. We measured LA volumes, booster performance, reservoir capacity as well as conduit function, and analyzed their association with adiposity measures. Results: All four adiposity measures were positively associated with greater LA volumes (all P < 0.05, while IAS and AVG fat were also related to larger LA kinetic energy and worse reservoir capacity (both P < 0.01. In multivariate models, IAS fat thickness remained independently associated with larger LA volumes, increased LA kinetic energy and ejection force (β-coef: 0.17 & 0.15, both P < 0.05, and impaired LA reservoir and conduit function (β-coef: −0.20 & −0.12, both P < 0.05 after adjusting for clinical variables. Conclusion: Accumulated visceral adiposity, especially interatrial fat depots, was associated with certain LA structural/functional remodeling characterized by impaired LA reservoir and conduit function though augmented kinetic energy and ejection performance. Our data suggested that interatrial fat burden may be associated with certain detrimental LA functions with compensatory LA adaptation in an asymptomatic population.

  11. Prognostic value of left atrial size and function in adults with tetralogy of Fallot.

    Science.gov (United States)

    Baggen, Vivan J M; Schut, Anne-Rose W; Cuypers, Judith A A E; Witsenburg, Maarten; Boersma, Eric; van den Bosch, Annemien E; Roos-Hesselink, Jolien W

    2017-06-01

    Left atrial (LA) size predicts cardiovascular outcome in chronic heart failure. Its prognostic value in adults with repaired tetralogy of Fallot (ToF) is unknown. This study therefore investigated the association of LA size and function with cardiovascular events in adults with ToF. Clinically stable adults with ToF who visited the outpatient clinic between 2011 and 2013 underwent echocardiography and were prospectively followed for the occurrence of death, heart failure, hospitalizations, arrhythmia, thromboembolic events, and re-interventions. LA maximal, minimal and pre-A wave volume, area and length were measured on the apical four-chamber view. Total, passive and active emptying fractions were calculated. In total, 134 patients were included (median age 35 [IQR 29-45] years, 65% male, 91% NYHA I). Median follow-up was 40 [IQR 32-47] months. Patients with a dilated LA (≥34mL/m 2 , 43%) were at higher risk of cardiovascular events (n=33, adjusted HR 2.48 [1.09-5.62], P=0.030). Analysis of LA volumes as continuous variables yielded similar conclusions. In addition, LA length (adjusted HR 2.49 [1.51-4.09], P<0.001), total emptying fraction (adjusted HR 0.96 [0.93-0.99], P=0.008), and active emptying fraction (adjusted HR 0.92 [0.87-0.96], P=0.001) were significantly associated with cardiovascular events. Standardized HRs indicated that LA length was the strongest prognostic marker. In addition, none of the patients with a normally sized LA died or developed heart failure. LA size and function can provide relevant prognostic information in clinically stable adults with repaired ToF. Especially LA length may be a valuable additional tool in the risk stratification of these patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Spatial Relation Between Left Atrial Anatomical Contact Areas and Circular Activation in Persistent Atrial Fibrillation.

    Science.gov (United States)

    Nakahara, Shiro; Yamaguchi, Takanori; Hori, Yuichi; Anjo, Naofumi; Hayashi, Akiko; Kobayashi, Sayuki; Komatsu, Takaaki; Sakai, Yoshihiko; Fukui, Akira; Tsuchiya, Takeshi; Taguchi, Isao

    2016-05-01

    Atrial low-voltage zones (LVZs) may be related to maintenance of atrial fibrillation (AF). The influence of left atrial (LA) contact areas (CoAs) on reentrant or rotor-like sources maintaining AF has not been investigated. Forty patients with persistent AF (PsAF) were analyzed. Three representative CoA regions in the LA (ascending aorta: anterior wall; descending aorta: left inferior pulmonary vein; and vertebrae: posterior wall) were visualized by enhanced CT. Using circular catheters, the LVZs (80% of the mean AF cycle length. A pivot was defined as the core of the localized circular activation. Anterior (39/40 patients, 98%), left pulmonary vein antrum (27/40, 68%), and posterior (19/40, 48%) CoAs were identified, and 80% (68/85) of those sites were overlapped by or close (<3 mm) to LVZs. Thirty-six (90%) patients demonstrated circular activation (3.1±1.7 sites/patients) along with significantly higher organized dominant frequencies (6.3 ± 0.5 Hz, regularity-index: 0.26 [0.23-0.41]) within the LA, and the average electrogram amplitude of those pivots was 0.30 mV (0.18-0.52). Of those sites, 55% (66/120) were located at or close to CoA regions. Catheter ablation including of LVZs neighboring CoAs terminated AF in 9 (23%) patients. External anatomical structures contacting the LA may be related to unique conduction properties in diseased myocardium necessary for PsAF maintenance. © 2016 Wiley Periodicals, Inc.

  13. Evaluation of Left Atrial Volumes Using Multidetector Computed Tomography: Comparison with Echocardiography

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Kim, Sang Jin; Kim, Tae Hoon; Lee, Sang Min; Hong, Yoo Jin; Rim, Se Joong

    2010-01-01

    To prospectively assess the relationship between the two different measurement methods for the evaluation of left atrial (LA) volume using cardiac multidetector computed tomography (MDCT) and to compare the results between cardiac MDCT and echocardiography. Thirty-five patients (20 men, 15 women; mean age, 60 years) underwent cardiac MDCT angiography for coronary artery disease. The LA volumes were measured using two different methods: the two dimensional (2D) length-based (LB) method measured along the three-orthogonal planes of the LA and the 3D volumetric threshold-based (VTB) method measured according to the threshold 3D segmentation of the LA. The results obtained by cardiac MDCT were compared with those obtained by echocardiography. The LA end-systolic and end-diastolic volumes (LAESV and LAEDV) measured by the 2D-LB method correlated well with those measured by the 3DVTB method using cardiac MDCT (r = 0.763, r = 0.786, p = 0.001). However, there was a significant difference in the LAESVs between the two measurement methods using cardiac MDCT (p < 0.05). The LAESV measured by cardiac MDCT correlated well with measurements by echocardiography (r = 0.864, p = 0.001), however with a significant difference (p < 0.01) in their volumes. The cardiac MDCT overestimated the LAESV by 22% compared to measurements by echocardiography. A significant correlation was found between the two different measurement methods for evaluating LA volumes by cardiac MDCT. Further, cardiac MDCT correlates well with echocardiography in evaluating the LA volume. However, there are significant differences in the LAESV between the two measurement methods using cardiac MDCT and between cardiac MDCT and echocardiography

  14. Left atrial appendage: morphology and function in patients with paroxysmal and persistent atrial fibrillation.

    Science.gov (United States)

    Park, Hwan-Cheol; Shin, Jinho; Ban, Ji-Eun; Choi, Jong-Il; Park, Sang-Weon; Kim, Young-Hoon

    2013-04-01

    The anatomical and functional characteristics of the left atrial appendage (LAA) and its relationships with anatomical remodeling and ischemic stroke in patients with atrial fibrillation (AF) have not been clearly established. The purpose of this study was to determine whether functional and morphological features of the LAA independently predict clinical outcome and stroke in patients with AF who underwent catheter ablation (CA). Two hundred sixty-four patients with AF, including 176 with paroxysmal AF (PAF, 54.0 ± 11.4 years old, M:F = 138:38) and 88 with persistent AF (PeAF, 56.4 ± 9.6 years old, M:F = 74:14) were studied. Of these patients, 31 (11.7 %) had a history of stroke/TIA (transient ischemic attack). The LA and LAA volumes were 124.0 ± 42.4 and 24.9 ± 4.3 ml in PeAF, these values were greater than those in PAF (81.2 ± 24.8 ml and 21.2 ± 5.1 ml, P stroke, stroke patients had larger LA volume (106.9 ± 23.0 vs. 94.0 ± 38.9 ml, P = 0.004) and had lower LAA EF (50.0 ± 11.0 vs. 65.7 ± 13.4 %, P stroke were age (P = 0.002) and LAA EF (P stroke/TIA and recurrence of AF after CA in paroxysmal AF patients. Further large scaled prospective study is required for validation.

  15. Left atrial strain: a new parameter for assessment of left ventricular filling pressure.

    Science.gov (United States)

    Cameli, Matteo; Mandoli, Giulia Elena; Loiacono, Ferdinando; Dini, Frank Lloyd; Henein, Michael; Mondillo, Sergio

    2016-01-01

    In order to obtain accurate diagnosis, treatment and prognostication in many cardiac conditions, there is a need for assessment of left ventricular (LV) filling pressure. While systole depends on ejection function of LV, diastole and its disturbances influence filling function and pressures. The commonest condition that represents the latter is heart failure with preserved ejection fraction in which LV ejection is maintained, but diastole is disturbed and hence filling pressures are raised. Significant diastolic dysfunction results in raised LV end-diastolic pressure, mean left atrial (LA) pressure and pulmonary capillary wedge pressure, all referred to as LV filling pressures. Left and right heart catheterization has traditionally been used as the gold standard investigation for assessing these pressures. More recently, Doppler echocardiography has taken over such application because of its noninvasive nature and for being patient friendly. A number of indices are used to achieve accurate assessment of filling pressures including: LV pulsed-wave filling velocities (E/A ratio, E wave deceleration time), pulmonary venous flow (S wave and D wave), tissue Doppler imaging (E' wave and E/E' ratio) and LA volume index. LA longitudinal strain derived from speckle tracking echocardiography (STE) is also sensitive in estimating intracavitary pressures. It is angle-independent, thus overcomes Doppler limitations and provides highly reproducible measures of LA deformation. This review examines the application of various Doppler echocardiographic techniques in assessing LV filling pressures, in particular the emerging role of STE in assessing LA pressures in various conditions, e.g., HF, arterial hypertension and atrial fibrillation.

  16. The importance of integrated left atrial evaluation: From hypertension to heart failure with preserved ejection fraction.

    Science.gov (United States)

    Beltrami, Matteo; Palazzuoli, Alberto; Padeletti, Luigi; Cerbai, Elisabetta; Coiro, Stefano; Emdin, Michele; Marcucci, Rossella; Morrone, Doralisa; Cameli, Matteo; Savino, Ketty; Pedrinelli, Roberto; Ambrosio, Giuseppe

    2018-02-01

    Functional analysis and measurement of left atrium are an integral part of cardiac evaluation, and they represent a key element during non-invasive analysis of diastolic function in patients with hypertension (HT) and/or heart failure with preserved ejection fraction (HFpEF). However, diastolic dysfunction remains quite elusive regarding classification, and atrial size and function are two key factors for left ventricular (LV) filling evaluation. Chronic left atrial (LA) remodelling is the final step of chronic intra-cavitary pressure overload, and it accompanies increased neurohormonal, proarrhythmic and prothrombotic activities. In this systematic review, we aim to purpose a multi-modality approach for LA geometry and function analysis, which integrates diastolic flow with LA characteristics and remodelling through application of both traditional and new diagnostic tools. The most important studies published in the literature on LA size, function and diastolic dysfunction in patients with HFpEF, HT and/or atrial fibrillation (AF) are considered and discussed. In HFpEF and HT, pulsed and tissue Doppler assessments are useful tools to estimate LV filling pressure, atrio-ventricular coupling and LV relaxation but they need to be enriched with LA evaluation in terms of morphology and function. An integrated evaluation should be also applied to patients with a high arrhythmic risk, in whom eccentric LA remodelling and higher LA stiffness are associated with a greater AF risk. Evaluation of LA size, volume, function and structure are mandatory in the management of patients with HT, HFpEF and AF. A multi-modality approach could provide additional information, identifying subjects with more severe LA remodelling. Left atrium assessment deserves an accurate study inside the cardiac imaging approach and optimised measurement with established cut-offs need to be better recognised through multicenter studies. © 2017 John Wiley & Sons Ltd.

  17. Accessory left atrial diverticulae: contractile properties depicted with 64-slice cine-cardiac CT.

    LENUS (Irish Health Repository)

    Killeen, Ronan P

    2012-02-01

    To assess the contractility of accessory left atrial appendages (LAAs) using multiphasic cardiac CT. We retrospectively analyzed the presence, location, size and contractile properties of accessory LAAs using multiphasic cardiac 64-slice CT in 102 consecutive patients (63 males, 39 females, mean age 57). Multiplanar reformats were used to create image planes in axial oblique, sagittal oblique and coronal oblique planes. For all appendages with an orifice diameter >or= 10 mm, axial and sagittal diameters and appendage volumes were recorded in atrial diastole and systole. Regression analysis was performed to assess which imaging appearances best predicted accessory appendage contractility. Twenty-three (23%) patients demonstrated an accessory LAA, all identified along the anterior LA wall. Dimensions for axial oblique (AOD) and sagittal oblique (SOD) diameters and sagittal oblique length (SOL) were 6.3-19, 3.4-20 and 5-21 mm, respectively. All appendages (>or=10 mm) demonstrated significant contraction during atrial systole (greatest diameter reduction was AOD [3.8 mm, 27%]). Significant correlations were noted between AOD-contraction and AOD (R = 0.57, P < 0.05) and SOD-contraction and AOD, SOD and SOL (R = 0.6, P < 0.05). Mean diverticulum volume in atrial diastole was 468.4 +\\/- 493 mm(3) and in systole was 171.2 +\\/- 122 mm(3), indicating a mean change in volume of 297.2 +\\/- 390 mm(3), P < 0.0001. Stepwise multiple regression analysis revealed SOL to be the strongest independent predictor of appendage contractility (R(2) = 0.86, P < 0.0001) followed by SOD (R(2) = 0.91, P < 0.0001). Accessory LAAs show significant contractile properties on cardiac CT. Those accessory LAAs with a large sagittal height or depth should be evaluated for contractile properties, and if present should be examined for ectopic activity during electrophysiological studies.

  18. Left Atrial Volume Index and Prediction of Events in Acute Coronary Syndrome: Solar Registry

    Directory of Open Access Journals (Sweden)

    Jose Alves Secundo Junior

    2014-10-01

    Full Text Available Background: According to some international studies, patients with acute coronary syndrome (ACS and increased left atrial volume index (LAVI have worse long-term prognosis. However, national Brazilian studies confirming this prediction are still lacking. Objective: To evaluate LAVI as a predictor of major cardiovascular events (MCE in patients with ACS during a 365-day follow-up. Methods: Prospective cohort of 171 patients diagnosed with ACS whose LAVI was calculated within 48 hours after hospital admission. According to LAVI, two groups were categorized: normal LAVI (≤ 32 mL/m2 and increased LAVI (> 32 mL/m2. Both groups were compared regarding clinical and echocardiographic characteristics, in- and out-of-hospital outcomes, and occurrence of ECM in up to 365 days. Results: Increased LAVI was observed in 78 patients (45%, and was associated with older age, higher body mass index, hypertension, history of myocardial infarction and previous angioplasty, and lower creatinine clearance and ejection fraction. During hospitalization, acute pulmonary edema was more frequent in patients with increased LAVI (14.1% vs. 4.3%, p = 0.024. After discharge, the occurrence of combined outcome for MCE was higher (p = 0.001 in the group with increased LAVI (26% as compared to the normal LAVI group (7% [RR (95% CI = 3.46 (1.54-7.73 vs. 0.80 (0.69-0.92]. After Cox regression, increased LAVI increased the probability of MCE (HR = 3.08, 95% CI = 1.28-7.40, p = 0.012. Conclusion: Increased LAVI is an important predictor of MCE in a one-year follow-up.

  19. Left atrial enlargement increases the risk of major adverse cardiac events independent of coronary vasodilator capacity

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Angela S. [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); National Heart Centre Singapore, Singapore (Singapore); Murthy, Venkatesh L.; Sitek, Arkadiusz; Gayed, Peter; Bruyere, John; Di Carli, Marcelo F. [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Wu, Justina [Brigham and Women' s Hospital, Division of Cardiology, Department of Medicine, and the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Dorbala, Sharmila [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Department of Radiology and the Division of Cardiology, Noninvasive Cardiovascular Imaging Section, Boston, MA (United States)

    2015-09-15

    Longstanding uncontrolled atherogenic risk factors may contribute to left atrial (LA) hypertension, LA enlargement (LAE) and coronary vascular dysfunction. Together they may better identify risk of major adverse cardiac events (MACE). The aim of this study was to test the hypothesis that chronic LA hypertension as assessed by LAE modifies the relationship between coronary vascular function and MACE. In 508 unselected subjects with a normal clinical {sup 82}Rb PET/CT, ejection fraction ≥40 %, no prior coronary artery disease, valve disease or atrial fibrillation, LAE was determined based on LA volumes estimated from the hybrid perfusion and CT transmission scan images and indexed to body surface area. Absolute myocardial blood flow and global coronary flow reserve (CFR) were calculated. Subjects were systematically followed-up for the primary end-point - MACE - a composite of all-cause death, myocardial infarction, hospitalization for heart failure, stroke, coronary artery disease progression or revascularization. During a median follow-up of 862 days, 65 of the subjects experienced a composite event. Compared with subjects with normal LA size, subjects with LAE showed significantly lower CFR (2.25 ± 0.83 vs. 1.95 ± 0.80, p = 0.01). LAE independently and incrementally predicted MACE even after accounting for clinical risk factors, medication use, stress left ventricular ejection fraction, stress left ventricular end-diastolic volume index and CFR (chi-squared statistic increased from 30.9 to 48.3; p = 0.001). Among subjects with normal CFR, those with LAE had significantly worse event-free survival (risk adjusted HR 5.4, 95 % CI 2.3 - 12.8, p < 0.0001). LAE and reduced CFR are related but distinct cardiovascular adaptations to atherogenic risk factors. LAE is a risk marker for MACE independent of clinical factors and left ventricular volumes; individuals with LAE may be at risk of MACE despite normal coronary vascular function. (orig.)

  20. Impact of Atrial Fibrillation Ablation on Left Ventricular Filling Pressure and Left Atrial Remodeling

    Directory of Open Access Journals (Sweden)

    Simone Nascimento dos Santos

    2014-12-01

    Full Text Available Background: Left ventricular (LV diastolic dysfunction is associated with new-onset atrial fibrillation (AF, and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. Objective: To evaluate the impact of AF ablation on estimated LV filling pressure. Methods: A total of 141 patients underwent radiofrequency (RF ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind, and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e' were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. Results: One hundred seventeen patients (82.9% were free of AF during the follow-up (average, 18 ± 5 months. LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001 compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns. Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001 but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns. The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001. Conclusion: Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure.

  1. Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device.

    Science.gov (United States)

    Xu, Bo; Betancor, Jorge; Sato, Kimi; Harb, Serge; Abdur Rehman, Karim; Patel, Kunal; Kumar, Arnav; Cremer, Paul C; Jaber, Wael; Rodriguez, L Leonardo; Schoenhagen, Paul; Wazni, Oussama

    Percutaneous left atrial appendage (LAA) occlusion is an emerging treatment option for patients with non-valvular atrial fibrillation who cannot tolerate oral anticoagulation. The Watchman device (Boston Scientific Corporation, Natick, MA, USA) is deployed at the ostium of the LAA, and an appropriately sized device is critical for successful occlusion. However, standardized imaging protocols for device sizing have not been established. We investigated the clinical utility of a standardized imaging protocol, with pre-procedural multi-detector cardiac computed tomography (MDCT), and intra-procedural transesophageal echocardiography (TEE), for Watchman device sizing. Patients who underwent Watchman device implantation between 2010 and 2016 at our center, and who had pre-procedural MDCT and intra-procedural TEE were included. MDCT measurements (CTmax, CTmin, CTmean), and TEE measurement (TEEmax) of the LAA ostium were determined for each case, and correlated with the final size of the Watchman device implanted. Demographic data and clinical outcomes were collected. The study included 80 patients (mean age: 75 ± 9.6 years; male: 68%; mean CHA2DS2-VASc score: 4.5 ± 1.4). CTmax of the LAA ostium correlated strongly with the final deployed Watchman device size (Spearman's rho: 0.81, p < 0.001), while TEEmax of the LAA ostium showed only moderate correlation with the final deployed Watchman device size (Spearman's rho: 0.61, p < 0.001). Implantation success rate was 100%. At a mean duration of follow-up of 197 days, there were no device-related complications (device embolization, cardiac perforation and pericardial tamponade). At follow-up, the vast majority of patients (76 patients; 95%) had either no or trivial (≤3 mm) residual peri-device leak on TEE. A standardized imaging protocol for assessment of Watchman device implantation incorporating pre-procedural MDCT and intra-procedural TEE, was associated with excellent procedural outcomes at a mean duration

  2. Impact of Atrial Fibrillation Ablation on Left Ventricular Filling Pressure and Left Atrial Remodeling

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Simone Nascimento dos, E-mail: simonens@cardiol.br [Instituto Brasília de Arritmia- Universidade de Brasília, DF (Brazil); Faculdade de Medicina (UnB), Brasília, DF (Brazil); Henz, Benhur Davi; Zanatta, André Rodrigues; Barreto, José Roberto; Loureiro, Kelly Bianca; Novakoski, Clarissa; Santos, Marcus Vinícius Nascimento dos; Giuseppin, Fabio F.; Oliveira, Edna Maria; Leite, Luiz Roberto [Instituto Brasília de Arritmia- Universidade de Brasília, DF (Brazil)

    2014-12-15

    Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. To evaluate the impact of AF ablation on estimated LV filling pressure. A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m{sup 2} ± 10.6 mL/m{sup 2} to 22.6 mL/m{sup 2} ± 1.1 mL/m{sup 2}, p < 0.001) compared to the non-successful group (37.7 mL/m{sup 2} ± 14.3 mL/m{sup 2} to 37.5 mL/m{sup 2} ± 14.5 mL/m{sup 2}, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001). Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure.

  3. Left atrial appendage function in prediction of paroxysmal atrial fibrilation in patients with untreated hypertension.

    Science.gov (United States)

    Tenekecioglu, Erhan; Agca, Fahriye Vatansever; Karaagac, Kemal; Ozluk, Ozlem Arican; Peker, Tezcan; Kuzeytemiz, Mustafa; Senturk, Muhammed; Yılmaz, Mustafa

    2014-01-01

    Abstract The onset of AF results in a significant increase in mortality rates and morbidity in hypertensive patients and this rhythm disorder exposes patients to a significantly increased risk of cerebral or peripheral embolisms. Tissue Doppler imaging was found to be useful in early detection of myocardial dysfunction in several diseases. It was shown that tissue Doppler analysis of the walls of the left atrial appendage (LAA) can give accurate information about the function of the LAA in hypertensive patients. In this study, we aimed to investigate and identify the specific predictive parameters for the onset of AF in patients with hypertension with tissue Doppler imaging of LAA. We studied age and sex matched 57 untreated hypertensive patients with paroxysmal atrial fibrillation (PAF) and 27 untreated hypertensive subjects without PAF. With transthoracic echocardiography, diastolic mitral A-velocity and LA maximal volume index which reflects reservoir function of left atrium was measured, with transesophageal echocardiography, LAA emptying velocity (LAA-PW D2) and tissue Doppler contracting velocity of LAA (LAA-TDI-D2) were measured. LA maximal volume index of the groups (22.28 ± 3.59 mL/m(2) in Group 1 versus 20.37 ± 3.97 mL/m(2) in Group 2, p = 0.07) and diastolic mitral A-velocity [0.93 (0.59-1.84) m/s in patients with PAF versus 0.90 (0.62-1.76) m/s in patients without PAF, p = 0.26] was not significantly different between study groups, during TEE, LAA-PW D2 (0.31 ± 0.04 m/s in Group 1 versus 0.33 ± 0.03 m/s in Group 2, p = 0.034) and LAA-TDI-D2 (0.18 ± 0.04 m/s in Group 1 versus 0.21 ± 0.05 m/s in Group 2, p = 0.014) were significantly decreased in Group 1. In this study, we found that in hypertensive PAF patients despite normal global LA functions, LAA contracting function was deteriorated. Tissue Doppler analysis of LAA is clinically usefull approach to detect the risk of developing PAF in

  4. Left Atrial Size and Function in a Canine Model of Chronic Atrial Fibrillation and Heart Failure

    Science.gov (United States)

    Goldberg, Adam; Kusunose, Kenya; Qamruddin, Salima; Rodriguez, L. Leonardo; Mazgalev, Todor N.; Griffin, Brian P.; Van Wagoner, David R.; Zhang, Youhua; Popović, Zoran B.

    2016-01-01

    Background Our aim was to assess how atrial fibrillation (AF) induction, chronicity, and RR interval irregularity affect left atrial (LA) function and size in the setting of underlying heart failure (HF), and to determine whether AF effects can be mitigated by vagal nerve stimulation (VNS). Methods HF was induced by 4-weeks of rapid ventricular pacing in 24 dogs. Subsequently, AF was induced and maintained by atrial pacing at 600 bpm. Dogs were randomized into control (n = 9) and VNS (n = 15) groups. In the VNS group, atrioventricular node fat pad stimulation (310 μs, 20 Hz, 3–7 mA) was delivered continuously for 6 months. LA volume and LA strain data were calculated from bi-weekly echocardiograms. Results RR intervals decreased with HF in both groups (p = 0.001), and decreased further during AF in control group (p = 0.014), with a non-significant increase in the VNS group during AF. LA size increased with HF (p<0.0001), with no additional increase during AF. LA strain decreased with HF (p = 0.025) and further decreased after induction of AF (p = 0.0001). LA strain decreased less (p = 0.001) in the VNS than in the control group. Beat-by-beat analysis showed a curvilinear increase of LA strain with longer preceding RR interval, (r = 0.45, p <0.0001) with LA strain 1.1% higher (p = 0.02) in the VNS-treated animals, independent of preceding RR interval duration. The curvilinear relationship between ratio of preceding and pre-preceding RR intervals, and subsequent LA strain was weaker, (r = 0.28, p = 0.001). However, VNS-treated animals again had higher LA strain (by 2.2%, p = 0.002) independently of the ratio of preceding and pre-preceding RR intervals. Conclusions In the underlying presence of pacing-induced HF, AF decreased LA strain, with little impact on LA size. LA strain depends on the preceding RR interval duration. PMID:26771573

  5. Impact of Atrial Fibrillation Ablation on Left Ventricular Filling Pressure and Left Atrial Remodeling

    International Nuclear Information System (INIS)

    Santos, Simone Nascimento dos; Henz, Benhur Davi; Zanatta, André Rodrigues; Barreto, José Roberto; Loureiro, Kelly Bianca; Novakoski, Clarissa; Santos, Marcus Vinícius Nascimento dos; Giuseppin, Fabio F.; Oliveira, Edna Maria; Leite, Luiz Roberto

    2014-01-01

    Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. To evaluate the impact of AF ablation on estimated LV filling pressure. A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m 2 ± 10.6 mL/m 2 to 22.6 mL/m 2 ± 1.1 mL/m 2 , p < 0.001) compared to the non-successful group (37.7 mL/m 2 ± 14.3 mL/m 2 to 37.5 mL/m 2 ± 14.5 mL/m 2 , p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001). Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure

  6. Left atrial enlargement increases the risk of major adverse cardiac events independent of coronary vasodilator capacity.

    Science.gov (United States)

    Koh, Angela S; Murthy, Venkatesh L; Sitek, Arkadiusz; Gayed, Peter; Bruyere, John; Wu, Justina; Di Carli, Marcelo F; Dorbala, Sharmila

    2015-09-01

    Longstanding uncontrolled atherogenic risk factors may contribute to left atrial (LA) hypertension, LA enlargement (LAE) and coronary vascular dysfunction. Together they may better identify risk of major adverse cardiac events (MACE). The aim of this study was to test the hypothesis that chronic LA hypertension as assessed by LAE modifies the relationship between coronary vascular function and MACE. In 508 unselected subjects with a normal clinical (82)Rb PET/CT, ejection fraction ≥40 %, no prior coronary artery disease, valve disease or atrial fibrillation, LAE was determined based on LA volumes estimated from the hybrid perfusion and CT transmission scan images and indexed to body surface area. Absolute myocardial blood flow and global coronary flow reserve (CFR) were calculated. Subjects were systematically followed-up for the primary end-point - MACE - a composite of all-cause death, myocardial infarction, hospitalization for heart failure, stroke, coronary artery disease progression or revascularization. During a median follow-up of 862 days, 65 of the subjects experienced a composite event. Compared with subjects with normal LA size, subjects with LAE showed significantly lower CFR (2.25 ± 0.83 vs. 1.95 ± 0.80, p = 0.01). LAE independently and incrementally predicted MACE even after accounting for clinical risk factors, medication use, stress left ventricular ejection fraction, stress left ventricular end-diastolic volume index and CFR (chi-squared statistic increased from 30.9 to 48.3; p = 0.001). Among subjects with normal CFR, those with LAE had significantly worse event-free survival (risk adjusted HR 5.4, 95 % CI 2.3 - 12.8, p < 0.0001). LAE and reduced CFR are related but distinct cardiovascular adaptations to atherogenic risk factors. LAE is a risk marker for MACE independent of clinical factors and left ventricular volumes; individuals with LAE may be at risk of MACE despite normal coronary vascular function.

  7. Assessments of pulmonary vein and left atrial anatomical variants in atrial fibrillation patients for catheter ablation with cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jing; Yang, Zhi-Gang; Xu, Hua-Yan; Shi, Ke; Long, Qi-Hua [Sichuan University, Department of Radiology, West China Hospital, Chengdu, Sichuan (China); Guo, Ying-Kun [Sichuan University, Department of Radiology, West China Second University Hospital, Chengdu (China)

    2017-02-15

    To provide a road map of pulmonary vein (PV) and left atrial (LA) variants in patients with atrial fibrillation (AF) before catheter ablation procedure using cardiac CT. Cardiac CT was performed in 1420 subjects for accurate anatomical information, including 710 patients with AF and 710 matched controls without AF. PV variants, PV ostia and spatial orientation, LA enlargement, and left atrial diverticulum (LAD) were measured, respectively. Differences between these two groups were also respectively compared. Some risk factors for the occurrence of LAD were analyzed. In total, PV variants were observed in 202 (28.5 %) patients with AF patients and 206 (29.0 %) controls without AF (p = 0.8153). The ostial sizes of all accessory veins were generally smaller than those of the typical four PVs (p = 0.0153 to 0.3958). There was a significant difference of LA enlargement between the AF and control groups (36.3 % vs. 12.5 %, p < 0.0001), while the prevalence of LAD was similar in these two groups (43.2 % vs. 41.9 %, p = 0.6293). PV variants are common. Detailed knowledge of PVs and LA variants are helpful for providing anatomical road map to determine ablation strategy. (orig.)

  8. Assessments of pulmonary vein and left atrial anatomical variants in atrial fibrillation patients for catheter ablation with cardiac CT

    International Nuclear Information System (INIS)

    Chen, Jing; Yang, Zhi-Gang; Xu, Hua-Yan; Shi, Ke; Long, Qi-Hua; Guo, Ying-Kun

    2017-01-01

    To provide a road map of pulmonary vein (PV) and left atrial (LA) variants in patients with atrial fibrillation (AF) before catheter ablation procedure using cardiac CT. Cardiac CT was performed in 1420 subjects for accurate anatomical information, including 710 patients with AF and 710 matched controls without AF. PV variants, PV ostia and spatial orientation, LA enlargement, and left atrial diverticulum (LAD) were measured, respectively. Differences between these two groups were also respectively compared. Some risk factors for the occurrence of LAD were analyzed. In total, PV variants were observed in 202 (28.5 %) patients with AF patients and 206 (29.0 %) controls without AF (p = 0.8153). The ostial sizes of all accessory veins were generally smaller than those of the typical four PVs (p = 0.0153 to 0.3958). There was a significant difference of LA enlargement between the AF and control groups (36.3 % vs. 12.5 %, p < 0.0001), while the prevalence of LAD was similar in these two groups (43.2 % vs. 41.9 %, p = 0.6293). PV variants are common. Detailed knowledge of PVs and LA variants are helpful for providing anatomical road map to determine ablation strategy. (orig.)

  9. Left atrial volume index is an independent predictor of hypertensive response to exercise in patients with hypertension.

    Science.gov (United States)

    Lee, Sang-Eun; Youn, Jong-Chan; Lee, Hye Sun; Park, Sungha; Lee, Sang-Hak; Cho, In-Jeong; Shim, Chi Young; Hong, Geu-Ru; Choi, Donghoon; Kang, Seok-Min

    2015-02-01

    A hypertensive response to exercise (HRE) is known to be associated with higher risk of heart failure and future cardiovascular events in patients with hypertension. Left atrial volume index (LAVI) is associated with the diastolic dysfunction, indicating exercise intolerance. Therefore, we investigated whether LAVI is relevant to HRE during cardiopulmonary exercise test (CPET). We studied 118 consecutive hypertensive patients (61 men, 57±11 years) and 45 normotensive control subjects (16 men, 54±8 years). Clinical characteristics, CPET, echocardiographic and laboratory findings were assessed at the time of enrollment. HRE was defined as maximum systolic blood pressure (SBP)⩾210 mm Hg in men and ⩾190 mm Hg in women. HRE was more prevalent in hypertensive patients compared with normotensive control subjects (50.8% vs. 20.0%, PHRE in normotensive control subjects, as were baseline SBP and LAVI in hypertensive group. In multivariate analysis, LAVI was found to be an independent predictor of HRE in hypertensive patients (P=0.020) but not in normotensive control subjects (P=0.936) when controlled for age, sex, body mass index and peak oxygen consumption. Higher LAVI, reflecting the duration and severity of increased left atrial pressure is independently associated with HRE in hypertensive patients, but not in normotensive control subjects.

  10. The effect of percutaneous transcatheter occlusion of left atrial appendage on left atrium and adjacent anatomic structure in canine

    International Nuclear Information System (INIS)

    Yang Zhihong; Wu Hong; Qin Yongwen; Hu Jianqiang; Ding Zhongru; Liu Zongjun; Liu Biao; Zheng Xing

    2009-01-01

    Objective: To observe the effect of percutaneous transcatheter occlusion of left atrial appendage (LAA) with a new self-manufactured LAA occluder on left atrium and adjacent anatomic structure in canine. Methods: A new self-manufactured LAA occluder was implanted into the LAA through a transseptal catheter in 20 dogs. Before and after the procedure, the experimental dogs were anaesthetized and examined by transthoracic echocardiography (TTE) to measure the diameter and the volume of the left atrium, the left superior pulmonary vein flow velocity and the left atrioventricular valve flow velocity separately. The contrast radiography of the LAA and the left coronary arteriography were performed. Results: The new LAA occluder was implanted successfully in 14 dogs. No obvious changes in the diameter and the volume of the left atrium, in left superior pulmonary vein flow velocity and in left atrioventricular valve flow velocity were found. On arteriography, left circumflex artery was normally displayed after the procedure. No migration of the occluder was seen on TTE and angiography after procedure. Conclusion: Percutaneous transcatheter occlusion of left atrial appendage with a new self-manufactured LAA occluder has no obvious effect on left atrium and adjacent anatomic structure in experimental canine, which indicates that the new-type device is a safe and feasible occluder for LAA. (authors)

  11. Left Atrial Appendage Closure Device With Delivery System: A Health Technology Assessment

    Science.gov (United States)

    Nevis, Immaculate; Falk, Lindsey; Wells, David; Higgins, Caroline

    2017-01-01

    Background Atrial fibrillation is a common cardiac arrhythmia, and 15% to 20% of those who have experienced stroke have atrial fibrillation. Treatment options to prevent stroke in people with atrial fibrillation include pharmacological agents such as novel oral anticoagulants or nonpharmacological devices such as the left atrial appendage closure device with delivery system (LAAC device). The objectives of this health technology assessment were to assess the clinical effectiveness and cost-effectiveness of the LAAC device versus novel oral anticoagulants in patients without contraindications to oral anticoagulants and versus antiplatelet agents in patients with contraindications to oral anticoagulants. Methods We performed a systematic review and network meta-analysis. We also conducted an economic literature review, economic evaluation, and budget impact analysis to assess the cost-effectiveness and budget impact of the LAAC device compared with novel oral anticoagulants and oral antiplatelet agents (e.g., aspirin). We also spoke with patients to better understand their preferences, perspectives, and values. Results Seven randomized controlled studies met the inclusion criteria for indirect comparison. Five studies assessed the effectiveness of novel oral anticoagulants versus warfarin, and two studies compared the LAAC device with warfarin. No studies were identified that compared the LAAC device with aspirin in patients in whom oral anticoagulants were contraindicated. Using the random effects model, we found that the LAAC device was comparable to novel oral anticoagulants in reducing stroke (odds ratio [OR] 0.85; credible interval [Cr.I] 0.63–1.05). Similarly, the reduction in the risk of all-cause mortality was comparable between the LAAC device and novel oral anticoagulants (OR 0.71; Cr.I 0.49–1.22). The LAAC device was found to be superior to novel oral anticoagulants in preventing hemorrhagic stroke (OR 0.45; Cr.I 0.29–0.79), whereas novel oral

  12. Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow.

    Science.gov (United States)

    Nakatani, S; Garcia, M J; Firstenberg, M S; Rodriguez, L; Grimm, R A; Greenberg, N L; McCarthy, P M; Vandervoort, P M; Thomas, J D

    1999-09-01

    The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p LA dP/dt(max) correlated well (r = 0.90, p LA dP/dt(max) predicted by the above equation with r = 0.94. A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

  13. Left atrial function to identify patients with atrial fibrillation at high risk of stroke: new insights from a large registry.

    Science.gov (United States)

    Leung, Melissa; van Rosendael, Philippe J; Abou, Rachid; Ajmone Marsan, Nina; Leung, Dominic Y; Delgado, Victoria; Bax, Jeroen J

    2018-04-21

    Atrial fibrillation (AF) is an independent risk factor for ischaemic stroke. The CHA2DS2-VASc is the most widely used risk stratification model; however, echocardiographic refinement may be useful, particularly in low risk AF patients. The present study examined the association between advanced echocardiographic parameters and ischaemic stroke, independent of CHA2DS2-VASc score. One thousand, three hundred and sixty-one patients (mean age 65±12 years, 74% males) with first diagnosis of AF and baseline transthoracic echocardiogram were followed by chart review for the occurrence of stroke over a mean of 7.9 years. Left atrial (LA) volumes, LA reservoir strain, P-wave to A' duration on tissue Doppler imaging (PA-TDI, reflecting total atrial conduction time), and left ventricular (LV) global longitudinal strain (GLS) were evaluated in patients with and without stroke. The independent association of these echocardiographic parameters with the occurrence of ischaemic stroke was evaluated with Cox proportional hazard models. One-hundred patients (7%) developed an ischaemic stroke, representing an annualized stroke rate of 0.9%. The incident stroke rate in the year following the first diagnosis of AF was 2.6% in the entire population and higher than the remainder of the follow-up period. Left atrial reservoir (14.5% vs. 18.9%, P = 0.005) and conduit strains were reduced (10.5% vs. 13.5%, P = 0.013), and PA-TDI lengthened (166 ms vs. 141 ms, P Left atrial reservoir strain and PA-TDI were independently associated with risk of stroke in a model including CHA2DS2-VASc score, age, and anticoagulant use. The assessment of LA reservoir strain and PA-TDI on echocardiography after initial CHA2DS2-VASc scoring provides additional risk stratification for stroke and may be useful to guide decisions regarding anticoagulation for patients upon first diagnosis of AF.

  14. Use of computed tomography to identify atrial fibrillation associated differences in left atrial wall thickness and density.

    Science.gov (United States)

    Dewland, Thomas A; Wintermark, Max; Vaysman, Anna; Smith, Lisa M; Tong, Elizabeth; Vittinghoff, Eric; Marcus, Gregory M

    2013-01-01

    Left atrial (LA) tissue characteristics may play an important role in atrial fibrillation (AF) induction and perpetuation. Although frequently used in clinical practice, computed tomography (CT) has not been employed to describe differences in LA wall properties between AF patients and controls. We sought to noninvasively characterize AF-associated differences in LA tissue using CT. CT images of the LA were obtained in 98 consecutive patients undergoing AF ablation and in 89 controls. A custom software algorithm was used to measure wall thickness and density in four prespecified regions of the LA. On average, LA walls were thinner (-15.5%, 95% confidence interval [CI] -23.2 to -7.8%, P identified significant thinning of the LA wall and regional alterations in tissue density in patients with a history of AF. These findings suggest differences in LA tissue composition can be noninvasively identified and quantified using CT. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  15. Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

    Science.gov (United States)

    Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik

    2015-12-01

    After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

  16. The incidence and characteristics of supraventricular tachycardia in left atrial isomerism: a high incidence of atrial fibrillation in young patients.

    Science.gov (United States)

    Miyazaki, Aya; Sakaguchi, Heima; Ohuchi, Hideo; Yamamoto, Tetsuya; Igarashi, Takehiro; Negishi, Jun; Toyota, Naoki; Kagisaki, Koji; Yagihara, Toshikatsu; Yamada, Osamu

    2013-06-20

    In left atrial isomerism (LAI), both atria show left atrial morphology. Although bradyarrhythmias are frequent and highly complex in LAI patients, previous studies have reported a low incidence of supraventricular tachycardia (SVT). To evaluate the incidence and characteristics of SVT in LAI, we retrospectively evaluated the clinical characteristics of SVTs in 83 patients with LAI (age at last follow-up, 15.3±10.5 years). There were 27 SVTs in 19 patients (23%), including nine episodes of atrial fibrillation (AF) and eight non-reentrant SVTs. Sixteen of the 19 patients with SVT had histories of atriotomy, but the three patients with AF or non-reentrant tachycardia had no history of atriotomy. The rates of freedom from SVT were 66% and 59% at ages of 20 and 30 years, respectively; the corresponding rates for freedom from AF were 89% and 74%. In multivariate analysis, the predictors of SVT were age (OR, 1.14; 95% CI, 1.06-1.26; p=0.003) and sinus node dysfunction (SND) (OR, 3.88; 95% CI, 1.57-13.34; p=0.01). In patients with LAI, SVTs are common, and AF and non-reentrant SVTs are the major type of SVTs. The incidence of AF was high in young patients with LAI. The lack of anatomical barriers in the atria that allow the formation of macro-reentrant circuits may account for the higher incidence of AF and non-reentrant SVT than macro-reentrant tachycardia. Moreover, the increasing prevalence of SND with age should contribute to a higher incidence of SVT. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Cost-effectiveness analysis of left atrial appendage occlusion compared with pharmacological strategies for stroke prevention in atrial fibrillation.

    Science.gov (United States)

    Lee, Vivian Wing-Yan; Tsai, Ronald Bing-Ching; Chow, Ines Hang-Iao; Yan, Bryan Ping-Yen; Kaya, Mehmet Gungor; Park, Jai-Wun; Lam, Yat-Yin

    2016-08-31

    Transcatheter left atrial appendage occlusion (LAAO) is a promising therapy for stroke prophylaxis in non-valvular atrial fibrillation (NVAF) but its cost-effectiveness remains understudied. This study evaluated the cost-effectiveness of LAAO for stroke prophylaxis in NVAF. A Markov decision analytic model was used to compare the cost-effectiveness of LAAO with 7 pharmacological strategies: aspirin alone, clopidogrel plus aspirin, warfarin, dabigatran 110 mg, dabigatran 150 mg, apixaban, and rivaroxaban. Outcome measures included quality-adjusted life years (QALYs), lifetime costs and incremental cost-effectiveness ratios (ICERs). Base-case data were derived from ACTIVE, RE-LY, ARISTOTLE, ROCKET-AF, PROTECT-AF and PREVAIL trials. One-way sensitivity analysis varied by CHADS2 score, HAS-BLED score, time horizons, and LAAO costs; and probabilistic sensitivity analysis using 10,000 Monte Carlo simulations was conducted to assess parameter uncertainty. LAAO was considered cost-effective compared with aspirin, clopidogrel plus aspirin, and warfarin, with ICER of US$5,115, $2,447, and $6,298 per QALY gained, respectively. LAAO was dominant (i.e. less costly but more effective) compared to other strategies. Sensitivity analysis demonstrated favorable ICERs of LAAO against other strategies in varied CHADS2 score, HAS-BLED score, time horizons (5 to 15 years) and LAAO costs. LAAO was cost-effective in 86.24 % of 10,000 simulations using a threshold of US$50,000/QALY. Transcatheter LAAO is cost-effective for prevention of stroke in NVAF compared with 7 pharmacological strategies. The transcatheter left atrial appendage occlusion (LAAO) is considered cost-effective against the standard 7 oral pharmacological strategies including acetylsalicylic acid (ASA) alone, clopidogrel plus ASA, warfarin, dabigatran 110 mg, dabigatran 150 mg, apixaban, and rivaroxaban for stroke prophylaxis in non-valvular atrial fibrillation management.

  18. Significant correlation of P-wave parameters with left atrial volume index and left ventricular diastolic function.

    Science.gov (United States)

    Tsai, Wei-Chung; Lee, Kun-Tai; Wu, Ming-Tsang; Chu, Chih-Sheng; Lin, Tsung-Hsien; Hsu, Po-Chao; Su, Ho-Ming; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2013-07-01

    The 12-lead electrocardiogram (ECG) is a commonly used tool to access left atrial enlargement, which is a marker of left ventricular diastolic dysfunction (LVDD). The aim of this study was to evaluate any association of the P-wave measurements in ECG with left atrial volume (LAV) index and LVDD. This study enrolled 270 patients. In this study, 4 ECG P-wave parameters corrected by heart rate, that is, corrected P-wave maximum duration (PWdurMaxC), corrected P-wave dispersion (PWdisperC), corrected P-wave area (PWareaC) and corrected mean P-wave duration (meanPWdurC), were measured. LAV and left ventricular diastolic parameters were measured from echocardiography. LVDD was defined as a pseudonormal or restrictive mitral inflow pattern. The 4 P-wave parameters were significantly correlated with the LAV index after adjusting for age, sex, diabetes, hypertension, coronary artery disease, body mass index and diastolic blood pressure in multivariate analysis. The standardized β coefficients of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 0.338, 0.298, 0.215 and 0.296, respectively. The 4 P-wave parameters were also significantly correlated with LVDD after multivariate logistic regression analysis. The odds ratios (95% confidence intervals) of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 1.03 (1.01-1.04), 1.02 (1.04-1.04), 1.04 (1.02-1.07) and 1.01 (1.00-1.02), respectively. This study demonstrated that PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were important determinants of the LAV index and LVDD. Therefore, screening patients by means of the 12-lead ECG may be helpful in identifying a high-risk group of increased LAV index and LVDD.

  19. Relationship of left atrial enlargement to persistence or development of ECG left ventricular hypertrophy in hypertensive patients: implications for the development of new atrial fibrillation

    DEFF Research Database (Denmark)

    Okin, Peter M; Gerdts, Eva; Wachtell, Kristian

    2010-01-01

    Persistence and development of ECG left ventricular hypertrophy (LVH) by Cornell product criteria are associated with an increased risk of atrial fibrillation compared with regression or continued absence of LVH. We postulated that this association might be in part mediated via greater left atrial...... enlargement (LAE) in patients with new and persistent ECG LVH....

  20. LEFT ATRIAL APPENDAGE CLOSURE AS AN ALTERNATIVE TO WARFARIN FOR STROKE PREVENTION IN ATRIAL FIBRILLATION: A PATIENT¬LEVEL META¬ANALYSIS

    Directory of Open Access Journals (Sweden)

    2015-01-01

    Full Text Available Holmes D.R. Jr, Doshi S.K., Kar S., et al. Left Atrial Appendage Closure as an Alternative to Warfarin for Stroke Prevention in Atrial Fibrillation: A Patient­Level Meta­Analysis // J. Am. Coll. Cardiol. – 2015. – Vol. 65. – P. 2614–2623.

  1. Left atrial remodelling in patients with myocardial infarction complicated by heart failure, left ventricular dysfunction, or both: the VALIANT Echo study

    DEFF Research Database (Denmark)

    Meris, Alessandra; Amigoni, Maria; Uno, Hajime

    2009-01-01

    AIMS: To assess the relationship between left atrial (LA) size and outcome after high-risk myocardial infarction (MI) and to study dynamic changes in LA size during long-term follow-up. METHODS AND RESULTS: The VALIANT Echocardiography study prospectively enrolled 610 patients with left ventricul...

  2. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    Science.gov (United States)

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  3. Left atrial accessory appendages, diverticula, and left-sided septal pouch in multi-slice computed tomography. Association with atrial fibrillation and cerebrovascular accidents.

    Science.gov (United States)

    Hołda, Mateusz K; Koziej, Mateusz; Wszołek, Karolina; Pawlik, Wiesław; Krawczyk-Ożóg, Agata; Sorysz, Danuta; Łoboda, Piotr; Kuźma, Katarzyna; Kuniewicz, Marcin; Lelakowski, Jacek; Dudek, Dariusz; Klimek-Piotrowska, Wiesława

    2017-10-01

    The aim of this study is to provide a morphometric description of the left-sided septal pouch (LSSP), left atrial accessory appendages, and diverticula using cardiac multi-slice computed tomography (MSCT) and to compare results between patient subgroups. Two hundred and ninety four patients (42.9% females) with a mean of 69.4±13.1years of age were investigated using MSCT. The presence of the LSSP, left atrial accessory appendages, and diverticula was evaluated. Multiple logistic regression analysis was performed to check whether the presence of additional left atrial structures is associated with increased risk of atrial fibrillation and cerebrovascular accidents. At least one additional left atrial structure was present in 51.7% of patients. A single LSSP, left atrial diverticulum, and accessory appendage were present in 35.7%, 16.0%, and 4.1% of patients, respectively. After adjusting for other risk factors via multiple logistic regression, patients with LSSP are more likely to have atrial fibrillation (OR=2.00, 95% CI=1.14-3.48, p=0.01). The presence of a LSSP was found to be associated with an increased risk of transient ischemic attack using multiple logistic regression analysis after adjustment for other risk factors (OR=3.88, 95% CI=1.10-13.69, p=0.03). In conclusion LSSPs, accessory appendages, and diverticula are highly prevalent anatomic structures within the left atrium, which could be easily identified by MSCT. The presence of LSSP is associated with increased risk for atrial fibrillation and transient ischemic attack. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. LEFT ATRIAL FIBROSIS IN PATIENTS WITH ATRIAL FIBRILLATION ACCORDING TO MAGNETIC RESONANCE IMAGING WITH LATE GADOLINIUM ENHANCEMENT

    Directory of Open Access Journals (Sweden)

    O. V. Stukalova

    2015-01-01

    Full Text Available Rationale: Atrial fibrillation (AF is the most common type of arrhythmia. Left atrial abnormalities in AF require further investigation.Aim: To evaluate characteristics of myocardial structure of the left atrium by magnetic resonance imaging (MRI with delayed contrast enhancement in patients with AF associated with essential hypertension (EH, in those without any cardiovascular disorders, and in patients with AF after cryoablation of the pulmonary artery orifice.Materials and methods: The study enrolled 53 patients with AF (mean age 56 years. Twenty eight of them had AF without any associated cardiovascular disorders (lone AF, or LAF group, 25 patients had AF related to EH (AF + EH group. Three patients had undergone anti-arrhythmic intervention. Cardiac MRI was performed in all patients with high resolution late gadolinium enhancement (LGE at 15–20 min after i.v. gadoversetamide (0.15 mmol/kg. For LGE MRI, we used a novel high resolution inversion recovery (inversion times 290–340 ms magnetic resonance pulse sequence with isotropic voxel (size 1.25 . 1.25 .2.5 mm and fat saturation. Left atrium walls were segmented semi-automatically on the LGE images. Left atrium fibrosis quantification was performed with the original software LGE Heart Analyzer, developed in Russian Cardiology Research and Production Complex (Moscow.Results: Left atrium fibrosis (mean, 9 [1.7; 18] % was found both in patients with AF + EH and with lone AF. There was a trend towards more significant left atrial fibrosis in the group of AF + EH, compared to that in the lone AF group (10.972 [6.98; 19.366] % vs 4.37 [0.893; 18.575] %, respectively, p = 0.1. The extent of left atrium fibrosis correlated with left atrium dilatation (r = 0.37, p < 0.001 and with the decreased ejection fraction (r = -0.4, р < 0.001. The patients who had undergone an antiarrhythmic intervention, demonstrated formation of intensive LGE zones in the ablation areas.Conclusion: Quantification of

  5. Association Between Local Bipolar Voltage and Conduction Gap Along the Left Atrial Linear Ablation Lesion in Patients With Atrial Fibrillation.

    Science.gov (United States)

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Sunaga, Akihiro; Tsujimura, Takuya; Matsuda, Yasuhiro; Mano, Toshiaki

    2017-08-01

    A bipolar voltage reflects a thick musculature where formation of a transmural lesion may be hard to achieve. The purpose of this study was to explore the association between local bipolar voltage and conduction gap in patients with persistent atrial fibrillation (AF) who underwent atrial roof or septal linear ablation. This prospective observational study included 42 and 36 consecutive patients with persistent AF who underwent roof or septal linear ablations, respectively. After pulmonary vein isolation, left atrial linear ablations were performed, and conduction gap sites were identified and ablated after first-touch radiofrequency application. Conduction gap(s) after the first-touch roof and septal linear ablation were observed in 13 (32%) and 19 patients (53%), respectively. Roof and septal area voltages were higher in patients with conduction gap(s) than in those without (roof, 1.23 ± 0.77 vs 0.73 ± 0.42 mV, p = 0.010; septal, 0.96 ± 0.43 vs 0.54 ± 0.18 mV, p = 0.001). Trisected regional analyses revealed that the voltage was higher at the region with a conduction gap than at the region without. Complete conduction block across the roof and septal lines was not achieved in 3 (7%) and 6 patients (17%), respectively. Patients in whom a linear conduction block could not be achieved demonstrated higher ablation area voltage than those with a successful conduction block (roof, 1.91 ± 0.74 vs 0.81 ± 0.51 mV, p = 0.001; septal, 1.15 ± 0.56 vs 0.69 ± 0.31 mV, p = 0.006). In conclusion, a high regional bipolar voltage predicts failure to achieve conduction block after left atrial roof or septal linear ablation. In addition, the conduction gap was located at the preserved voltage area. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Percutaneous closure of the left atrial appendage for prevention of thromboembolism in atrial fibrillation for patients with contraindication to or failure of oral anticoagulation: a single-center experience.

    Science.gov (United States)

    Faustino, Ana; Paiva, Luís; Providência, Rui; Trigo, Joana; Botelho, Ana; Costa, Marco; Leitão-Marques, António

    2013-06-01

    In non-valvular atrial fibrillation 90% of thrombi originate in the left atrial appendage (LAA). Percutaneous LAA closure has been shown to be non-inferior to warfarin for prevention of thromboembolism. To evaluate the initial experience of a single center in percutaneous LAA closure in patients with high thromboembolic risk and in whom oral anticoagulation was impractical or contraindicated or had failed. Patients with non-valvular atrial fibrillation and CHADS2 score ≥2 in whom oral anticoagulation was impractical or contraindicated or had failed underwent percutaneous LAA closure according to the standard technique. After the procedure, dual antiplatelet therapy was maintained for one month, followed by single antiplatelet therapy indefinitely. Patients were followed by clinical assessment and transthoracic and transesophageal echocardiography. The procedure was performed in 22 of the 23 selected patients (95.7%), mean age 70±9 years, CHADS2 score 3.2±0.9 and CHA2DS2-VASC score 4.7±1.4. Intraprocedural device replacement was necessary only in the first patient, due to oversizing. The following periprocedural complications were observed: one femoral pseudoaneurysm, three femoral hematomas and two minor oropharyngeal bleeds, resolved by local hemostatic measures. During a 12±8 month follow-up a mild peri-device flow and a thrombus adhering to the device, resolved under with enoxaparin therapy, were identified. The rate of transient ischemic attack (TIA)/stroke was lower than expected according to the CHADS2 score (0 vs. 6.7±2.2%). In our initial experience, this procedure proved to be a feasible, safe and effective alternative for atrial fibrillation patients in whom oral anticoagulation is not an option. Only relatively minor complications were observed, with a lower than expected TIA/stroke rate. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  7. Efficacy and safety of left atrial appendage closure with WATCHMAN in patients with or without contraindication to oral anticoagulation: 1-Year follow-up outcome data of the EWOLUTION trial.

    Science.gov (United States)

    Boersma, Lucas V; Ince, Hueseyin; Kische, Stephan; Pokushalov, Evgeny; Schmitz, Thomas; Schmidt, Boris; Gori, Tommaso; Meincke, Felix; Protopopov, Alexey Vladimir; Betts, Timothy; Foley, David; Sievert, Horst; Mazzone, Patrizio; De Potter, Tom; Vireca, Elisa; Stein, Kenneth; Bergmann, Martin W

    2017-09-01

    Left atrial appendage (LAA) occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials. EWOLUTION was designed to provide data in routine practice from a prospective multicenter registry. A total of 1025 patients scheduled for a WATCHMAN implant were prospectively and sequentially enrolled at 47 centers. Indication for LAA closure was based on European Society of Cardiology guidelines. Follow-up and transesophageal echocardiography (TEE) were performed per local practice. The baseline CHA 2 DS 2 -VASc score was 4.5 ± 1.6; the mean age was 73.4 ± 9 years; previous transient ischemic attack/ischemic stroke was present in 312 (30.5%), 155 (15.1%) had previous hemorrhagic stroke, and 320 (31.3%) had a history of major bleeding; and 750 (73%) were deemed unsuitable for oral anticoagulation therapy. WATCHMAN implant succeeded in 1005 (98.5%) of patients, without leaks >5 mm in 1002 (99.7%) with at least 1 TEE follow-up in 875 patients (87%). Antiplatelet therapy was used in 784 (83%), while vitamin K antagonists were used in only 75 (8%). At 1 year, mortality was 98 (9.8%), reflecting the advanced age and comorbidities in this population. Device thrombus was observed in 28 patients at routine TEE (3.7%) and was not correlated with the drug regimen (P = .14). Ischemic stroke rate was 1.1% (relative risk 84% vs estimated historical data); the major bleeding rate was 2.6% and was predominantly (2.3%) nonprocedure/device related. LAA closure with the WATCHMAN device has a high implant and sealing success. This method of stroke risk reduction appears to be safe and effective with an ischemic stroke rate as low as 1.1%, even though 73% of patients had a contraindication to and were not using oral anticoagulation. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  8. A Case of Atrial Tachycardia Circulating around a Left Atrial Roof Scar with Diabetes Mellitus and Renal Failure on Hemodialysis

    Directory of Open Access Journals (Sweden)

    Naoko Hijioka

    2016-01-01

    Full Text Available Introduction. Little is known about the effects of volume change by hemodialysis (HD and mechanical stress caused by an anatomical structure being in contact with the left atrium on the progression of atrial remodeling. We experienced a case of atrial tachycardia (AT in a patient who had left atrial (LA scarring at the LA roof and a low-voltage area with slow conduction around the LA scar as components of AT circuit. Here, we present the conceivable hypothesis of the LA scar and the low-voltage area formation. Our concept can be useful in developing a strategy for ablation in a patient with chronic renal failure (CRF on HD. Case Report. A 65-year-old man with CRF on HD was referred for AT ablation. Three-dimensional electroanatomical mapping revealed that the AT conducted around an LA scar in a counterclockwise fashion. There was a slow conduction area at the superior side of the LA scar, where the AT was terminated during the ablation. Computed tomography indicated a close relationship between the LA and the anatomical structures (ascending aorta and pulmonary artery. Conclusion. Volume change by HD and close contact of anatomical structures to the LA can promote atrial remodeling, resulting in AT occurrence.

  9. The influence of right ventricular apical pacing on left atrial volume in patients with normal left ventricular function

    Directory of Open Access Journals (Sweden)

    AR Moaref1

    2008-03-01

    Full Text Available Background: Right ventricular apical (RVA pacing has been reported to induce several deleterious effects particularly in the presence of structural heart disease but can also involve patients with normal left ventricular (LV function. Left atrial (LA enlargement is one of these effects, but the majority of studies have measured LA dimension rather than volume.Objective: The present prospective study was designed to assess the effect of RVA pacing on LA volume in patients with normal LV function.Patients and Methods: The study comprised 41 consecutive patients with LV ejection fraction ≥ 45% and LV end diastolic dimension ≤ 56 mm who underwent single-or dual- chamber pacemaker implantation in RVA and followed for LA volume measurement and pacemaker analysis at least during the ensuing 4.2 months. Results: In all, 21 patients were excluded from the study due to five spontaneous wide QRS complex (≥120msec, one recent acute coronary syndrome,one significant valvular heart disease, three pacing frequency <90%, eight death or losing follow up in three cases. In remaining 20 patients, LA volume ragned from 21 to 54 mm3 with mean of 37.3±9.7 mm3 prior to pacemaker implantation that increased to 31 to 103 mm3 (54.3±17.0 during follow-up (P<0.001.Conclusion: RVA pacing might lead to an increase in LA volume even in patients with normal LV function.

  10. [New technology for prevention of embolic events in atrial fibrillation: a systematic review on percutaneous endovascular left atrial appendage closure].

    Science.gov (United States)

    Danna, Paolo; Sagone, Antonio; Proietti, Riccardo; Arensi, Andrea; Viecca, Maurizio; Santangeli, Pasquale; Di Biase, Luigi; Natale, Andrea

    2012-09-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia. The mortality rate of patients with AF is doubled as compared to non-fibrillating controls. The most relevant complication of AF is a major increase in the risk of stroke. The gold standard in reducing cerebrovascular events in AF is warfarin therapy, which is not free from contraindications and limitations. The left atrial appendage (LAA) is the main source of emboli causing stroke in AF. LAA closure is a seducing approach to stroke risk reduction in AF without anticoagulation. Since 1949, heart surgeons have performed LAA closure or amputation in patients with AF. Percutaneous endovascular LAA closure is a new, less invasive, technique to reach the goal. Several devices have been used to perform this intervention, and the results of published trials are encouraging in terms of effectiveness and relative safety of this attractive technique. In this review we examine the published trials and data on percutaneous LAA closure, with particular attention to the risks and benefits of this procedure.

  11. Percutaneous left atrial appendage occlusion in atrial fibrillation patients with a contraindication to oral anticoagulation: a focused review.

    Science.gov (United States)

    Nishimura, Marin; Sab, Shiv; Reeves, Ryan R; Hsu, Jonathan C

    2017-12-08

    Stroke is the most feared complication of atrial fibrillation (AF). Although oral anticoagulation with non-vitamin K antagonist and non-vitamin K antagonist oral anticoagulants (NOACs) have been established to significantly reduce risk of stroke, real-world use of these agents are often suboptimal due to concerns for adverse events including bleeding from both patients and clinicians. Particularly in patients with previous serious bleeding, oral anticoagulation may be contraindicated. Left atrial appendage occlusion (LAAO), mechanically targeting the source of most of the thrombi in AF, holds an immense potential as an alternative to OAC in management of stroke prophylaxis. In this focused review, we describe the available evidence of various LAAO devices, detailing data regarding their use in patients with a contraindication for oral anticoagulation. Although some questions of safety and appropriate use of these new devices in patients who cannot tolerate anticoagulation remain, LAAO devices offer a significant step forward in the management of patients with AF, including those patients who may not be able to be prescribed OAC at all. Future studies involving patients fully contraindicated to OAC are warranted in the era of LAAO devices for stroke risk reduction. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  12. Thallium pulmonary scintigraphy. Relationship to pulmonary fluid volumes during left atrial hypertension and the acute release of pressure

    International Nuclear Information System (INIS)

    Slutsky, R.A.

    1984-01-01

    To evaluate the relationship between thallium-201 lung activity and pulmonary fluid volumes, we compared thallium pulmonary scintigrams with measures of intravascular (PBV), extravascular (EVLW) and total lung water (TLW) during gradual left atrial (LA) hypertension and then serially after the acute release of pressure. The study group was composed of nine mongrel dogs who were each studied at seven levels of elevated LA pressure, and then every 15 minutes for 2 hours after the acute release of pressure. During LA pressure (congestion phase) elevation, lung counts (normalized for myocardial activity), correlated best with TLW (r . .91), rather than PBV (r . .84) or EVLW (r . .81). After the release of pressure (recovery phase), lung counts correlated well with EVLW (r . .92) and TLW (r . .82), but not with PBV (r . .28). Postmortem lung counts from 197 separate lung sections correlated well with the corresponding wet weight/dry weight ratio from that section (r . .81). Thus, we conclude that changes in pulmonary thallium emissions during cardiogenic pulmonary edema relate to corresponding changes in pulmonary fluid volumes. During congestion, the confounding effects of nonlinear increases in EVLW and PBV make thallium emissions more a marker of TLW than either the intravascular or extravascular pulmonary fluid compartment. After pressure release, PBV immediately returns to normal, at which time EVLW and pulmonary emissions correlate closely. These latter data, more applicable to postexercise stress thallium data, lend support to the hypothesis that elevated pulmonary emissions during postexercise thallium scintigrams reflect elevations in EVLW that develop during exercise

  13. Contrast-enhanced CMR in patients after percutaneous closure of the left atrial appendage: A pilot study

    Directory of Open Access Journals (Sweden)

    Petersen Steffen E

    2011-07-01

    Full Text Available Abstract Background To evaluate the feasibility and value of first-pass contrast-enhanced dynamic and post-contrast 3D CMR in patients after transcatheter occlusion of left atrial appendage (LAA to identify incorrect placement and persistent leaks. Methods 7 patients with different occluder systems (n = 4 PLAATO; n = 2 Watchman; n = 1 ACP underwent 2 contrast-enhanced (Gd-DOTA CMR sequences (2D TrueFISP first-pass perfusion and 3D-TurboFLASH to assess localization, artifact size and potential leaks of the devices. Perfusion CMR was analyzed visually and semi-quantitatively to identify potential leaks. Results All occluders were positioned within the LAA. The ACP occluder presented the most extensive artifact size. Visual assessment revealed a residual perfusion of the LAA apex in 4 cases using first-pass perfusion and 3D-TurboFLASH indicating a suboptimal LAA occlusion. By assessing signal-to-time-curves the cases with a visually detected leak showed a 9-fold higher signal-peak in the LAA apex (567 ± 120% increase from baseline signal than those without a leak (61 ± 22%; p Conclusion This CMR pilot study provides valuable non-invasive information in patients after transcatheter occlusion of the LAA to identify correct placement and potential leaks. We recommend incorporating CMR in future clinical studies to evaluate new device types.

  14. A stochastic approach for automatic registration and fusion of left atrial electroanatomic maps with 3D CT anatomical images

    International Nuclear Information System (INIS)

    Cristoforetti, Alessandro; Mase, Michela; Faes, Luca; Centonze, Maurizio; Greco, Maurizio Del; Antolini, Renzo; Nollo, Giandomenico; Ravelli, Flavia

    2007-01-01

    The integration of electroanatomic maps with highly resolved computed tomography cardiac images plays an important role in the successful planning of the ablation procedure of arrhythmias. In this paper, we present and validate a fully-automated strategy for the registration and fusion of sparse, atrial endocardial electroanatomic maps (CARTO maps) with detailed left atrial (LA) anatomical reconstructions segmented from a pre-procedural MDCT scan. Registration is accomplished by a parameterized geometric transformation of the CARTO points and by a stochastic search of the best parameter set which minimizes the misalignment between transformed CARTO points and the LA surface. The subsequent fusion of electrophysiological information on the registered CT atrium is obtained through radial basis function interpolation. The algorithm is validated by simulation and by real data from 14 patients referred to CT imaging prior to the ablation procedure. Results are presented, which show the validity of the algorithmic scheme as well as the accuracy and reproducibility of the integration process. The obtained results encourage the application of the integration method in post-intervention ablation assessment and basic AF research and suggest the development for real-time applications in catheter guiding during ablation intervention

  15. Transcatheter treatment of heart failure with preserved or mildly reduced ejection fraction using a novel interatrial implant to lower left atrial pressure

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Reddy, Vivek; Kaye, David

    2014-01-01

    BACKGROUND: Heart failure with preserved or mildly reduced ejection fraction (HFpEF) is common and, to date, therapeutic options are limited. Increased left atrial pressure is a key contributor to the symptoms associated with HFpEF, particularly during physical activity. We report the 30-day...... outcome of patients treated with a novel device intended to lower left atrial pressure by creating an 8 mm permanent shunt in the atrial septum. METHODS AND RESULTS: Eleven patients were enrolled in the pilot trial. Key inclusion criteria were: EF >45%; baseline PCWP ≥15 mmHg (rest), or ≥ 25 mm...... patients, one class in five patients, and worsened by one class in one patient. No patient developed pulmonary hypertension. Two serious adverse events occurred; heart failure re-hospitalization, and implant malposition successfully treated with a new device. CONCLUSION: Contemporary management of HFp...

  16. Percutaneous Occlusion of the Left Atrial Appendage with the Watchman Device in an Active Duty Sailor with Atrial Fibrillation and Recurrent Thromboembolism Despite Appropriate Use of Oral Anticoagulation.

    Science.gov (United States)

    Cox, Justin M; Choi, Anthony J; Oakley, Luke S; Francisco, Gregory M; Nayak, Keshav R

    2018-05-23

    Atrial fibrillation is the most common significant cardiac arrhythmia and is associated with a five-fold increased risk of stroke from thromboembolism. Over 94% of these emboli arise from the left atrial appendage. Systemic embolic phenomena are rare, accounting for less than 1 out of 10 of all embolic events, but have a similar prevention strategy. Anticoagulation significantly reduces the risk of these events, and thus forms the cornerstone of therapy for most patients with atrial fibrillation. Left atrial appendage occlusion with the Watchman device is a recently approved alternative for stroke prevention in selected patients. We present a case of an active duty U.S. Navy sailor at low risk for thromboembolism who nonetheless suffered recurrent thromboembolic events despite appropriate anticoagulation, and thus underwent Watchman implantation. The therapy in this case will ideally provide a lifetime of protection from recurrent systemic embolization while allowing the patient to continue his active duty military career without restriction due to oral anticoagulation.

  17. Atrial Fibrillation associated chromosome 4q25 variants are not associated with PITX2c expression in human adult left atrial appendages.

    Directory of Open Access Journals (Sweden)

    Shamone R Gore-Panter

    Full Text Available Atrial Fibrillation (AF, the most common sustained arrhythmia, has a strong genetic component, but the mechanism by which common genetic variants lead to increased AF susceptibility is unknown. Genome-wide association studies (GWAS have identified that the single nucleotide polymorphisms (SNPs most strongly associated with AF are located on chromosome 4q25 in an intergenic region distal to the PITX2 gene. Our objective was to determine whether the AF-associated SNPs on chromosome 4q25 were associated with PITX2c expression in adult human left atrial appendages. Analysis of a lone AF GWAS identified four independent AF risk SNPs at chromosome 4q25. Human adult left atrial appendage tissue was obtained from 239 subjects of European Ancestry and used for SNP analysis of genomic DNA and determination of PITX2c RNA expression levels by quantitative PCR. Subjects were divided into three groups based on their history of AF and pre-operative rhythm. AF rhythm subjects had higher PITX2c expression than those with history of AF but in sinus rhythm. PITX2c expression was not associated with the AF risk SNPs in human adult left atrial appendages in all subjects combined or in each of the three subgroups. However, we identified seven SNPs modestly associated with PITX2c expression located in the introns of the ENPEP gene, ∼54 kb proximal to PITX2. PITX2c expression in human adult left atrial appendages is not associated with the chromosome 4q25 AF risk SNPs; thus, the mechanism by which these SNPs are associated with AF remains enigmatic.

  18. Effect of preload reduction by hemodialysis on left atrial volume and echocardiographic Doppler parameters in patients with end-stage renal disease.

    Science.gov (United States)

    Barberato, Silvio H; Mantilla, Diego E V; Misocami, M Arcio; Gonçalves, Simone M; Bignelli, Alexandre T; Riella, Miguel C; Pecoits-Filho, Roberto

    2004-11-01

    Left atrial (LA) volume has been proposed as a less preload-dependent parameter of diastolic function than Doppler mitral inflow. We hypothesize that in the absence of mitral regurgitation and atrial fibrilation, LA enlargement could be a more practical (and relatively preload-independent) method for the evaluation of left ventricular diastolic function. The aim of the present study was to determine the effects of preload reduction by hemodialysis on LA volume.

  19. [Quantitative Measurements on the Blood Flow Fields of Left Atrial Appendage using Vector Flow Mapping in Patients with Nonvalvular Atrial Fibrillation].

    Science.gov (United States)

    Cai, Yu-Yan; Wei, Xin; Zhang, Xiao-Ling; Liu, Gu-Yue; Li, Xi; Tang, Hong

    2018-01-01

    To quantify the hemodynamic characteristics of patients with nonvalvular atrial fibrillation. Twenty patients with paroxysmal atrial fibrillation and 15 patients with persistent atrial fibrillation enrolled in this study,while 12 patients with sinus rhythms served as controls. The hemodynamic characteristics of the patients in left atrial appendage were measured by transesophageal echocardiography (TEE) and vector flow mapping (VFM) using indicators such as vectors,vortex and energy loss (EL). ① Significant differences appeared between the patients with atrial fibrillation and the controls in heart rate,size of left atrium,size of left atrial appendage (LAA),and velocities of LAA filling and emptying. ② Regular vectors in LAA in early systole and late diastole were found in the patients with paroxysmal atrial fibrillation and the controls; whereas,irregular vectors with direction alternating were visualized in the whole cardiac cycle in the patients with persistent atrial fibrillation. ③ Small vortexes were observed at the opening of the left atrial appendage in late diastole in the patients with paroxysmal atrial fibrillation and the controls. ④ Peak EL values occurred in early systole and late diastole in the patients with paroxysmal atrial fibrillation and the controls. But the patients with persistent atrial fibrillation had increased EL values over the whole cardiac cycle. VFM can visualize and quantify the hemodynamics of LAA in patients with different heart rhythms. It may provide a new method for assessing atrial fibrillation. CopyrightCopyright© by Editorial Board of Journal of Sichuan University (Medical Science Edition).

  20. Diagnostic accuracy of electrocardiographic P wave related parameters in the assessment of left atrial size in dogs with degenerative mitral valve disease.

    Science.gov (United States)

    Soto-Bustos, Ángel; Caro-Vadillo, Alicia; Martínez-DE-Merlo, Elena; Alonso-Alegre, Elisa González

    2017-10-07

    The purpose of this research was to compare the accuracy of newly described P wave-related parameters (P wave area, Macruz index and mean electrical axis) with classical P wave-related parameters (voltage and duration of P wave) for the assessment of left atrial (LA) size in dogs with degenerative mitral valve disease. One hundred forty-six dogs (37 healthy control dogs and 109 dogs with degenerative mitral valve disease) were prospectively studied. Two-dimensional echocardiography examinations and a 6-lead ECG were performed prospectively in all dogs. Echocardiography parameters, including determination of the ratios LA diameter/aortic root diameter and LA area/aortic root area, were compared to P wave-related parameters: P wave area, Macruz index, mean electrical axis voltage and duration of P wave. The results showed that P wave-related parameters (classical and newly described) had low sensitivity (range=52.3 to 77%; median=60%) and low to moderate specificity (range=47.2 to 82.5%; median 56.3%) for the prediction of left atrial enlargement. The areas under the curve of P wave-related parameters were moderate to low due to poor sensitivity. In conclusion, newly P wave-related parameters do not increase the diagnostic capacity of ECG as a predictor of left atrial enlargement in dogs with degenerative mitral valve disease.

  1. Can contrast-enhanced multi-detector computed tomography replace transesophageal echocardiography for the detection of thrombogenic milieu and thrombi in the left atrial appendage. A prospective study with 124 patients; Kann die kontrastmittelverstaerkte Mehrzeilen-Computertomografie die transoesophageale Echokardiografie bei der Detektion von thrombogenem Milieu und Vorhofohrthromben ersetzen? Eine prospektive Studie mit 124 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Homsi, R.; Luetkens, J.A.; Schild, H.H.; Naehle, C.P. [Bonn Univ. (Germany). Dept. of Radiology; Nath, B. [SHG-KLliniken Voelklingen (Germany). Dept. of Medicine I - Cardiology; Schwab, J.O. [Bonn Univ. (Germany). Dept. of Medicine I - Cardiology

    2016-01-15

    To assess the diagnostic value of contrast-enhanced multi-detector computed tomography (MD-CT) for identifying patients with left atrial appendage (LAA) thrombus or circulatory stasis. 124 patients with a history of atrial fibrillation and/or cerebral ischemia (83 men, mean age 58.6 ± 12.4 years) and with a clinical indication for MD-CT of the heart and for transesophageal echocardiography (TEE) were included in the study. LAA thrombus or thrombogenic milieu was visually identified in TEE and MD-CT. In addition, MD-CT was analyzed quantitatively measuring the Hounsfield units (HU) of the left atrium (LA), the LAA and the ascending aorta (AA), and calculating the HU ratios LAA/AA (HU [LAA/AA]) und LAA/LA (HU [LAA/LA]). Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) were calculated. The prevalence of a thrombus or thrombogenic milieu as assessed by TEE was 21.8 %. The HU ratio was lower in patients with thrombus or thrombogenic milieu (HU [LAA/AA]: 0.590 ± 0.248 vs. 0.909 ± 0.141; p < 0.001 und HU [LAA/LA] 0.689 ± 0.366 vs. 1.082 ± 0.228; p < 0.001). For the diagnosis of thrombus or a thrombogenic milieu, visual analysis yielded a sensitivity of 81.5 %, a specificity of 96.9 %, a PPV of 87.5 % and a NPV of 95.2 %. By combining visual and quantitative analysis with one criterion being positive, the specificity decreased to 91.8 %, the sensitivity to 77.8 %, the PPV to 72.4 %, and the NPV to 94.9 %. Visual analysis of the LAA in the evaluation of thrombus or thrombogenic milieu yields a high NPV of 95.1 % and may especially be useful to rule out LAA thrombi in patients with contraindications for TEE. Additional calculation of HU ratios did not improve the diagnostic performance of MD-CT.

  2. Assessment of the effect of left atrial cryoablation enhanced by ganglionated plexi ablation in the treatment of atrial fibrillation in patients undergoing open heart surgery.

    Science.gov (United States)

    Bárta, Jiří; Brát, Radim

    2017-08-17

    The aim of our study was to investigate, whether enhancement of left atrial cryoablation by ablation of the autonomic nervous system of left atrium leads to influencing the outcomes of surgical treatment of atrial fibrillation in patients with structural heart disease undergoing open-heart surgery. The observed patient file consisted of 100 patients, who have undergone a combined open-heart surgery at our department between July 2012 and December 2014. The patients were indicated for the surgical procedure due to structural heart disease, and suffered from paroxysmal, persistent, or long-standing persistent atrial fibrillation. In all cases, left atrial cryoablation was performed in the extent of isolation of pulmonary veins, box lesion, connecting lesion with mitral annulus, amputation of the left atrial appendage and connecting lesion of the appendage base with left pulmonary veins. Furthermore, 35 of the patients underwent mapping and radiofrequency ablation of ganglionated plexi, together with discision and ablation of the ligament of Marshall (Group GP). A control group was consisted of 65 patients without ganglionated plexi intervention (Group LA). The main primary outcome was establishment and duration of sinus rhythm in the course of one-year follow-up. Evaluation of the number of patients with a normal sinus rhythm in per cent has shown comparable values in both groups (Group GP - 93.75%, Group LA - 86.67%, p = 0.485); comparable results were also observed in patients with normal sinus rhythm without anti-arrhythmic treatment in the 12th month (Group GP - 50%, Group LA - 47%, p = 0.306). We have not observed any relation between the recurrence of atrial fibrillation and the presence of a mitral valve surgery, or between the presence of a mitral and tricuspid valves surgery and between the left atrial diameter > 50 mm. Enhancement of left atrial cryoablation by gangionated plexi ablation did not influence the outcomes of surgical ablation due to

  3. [Stroke. are there any difference between patients with or without patent foramen ovale in left atrial appendage systolic function?].

    Science.gov (United States)

    Contreras, Alejandro E; Perrote, Federico; Concari, Ignacio; Brenna, Eduardo J; Lucero, Cecilia

    2012-01-01

    The aim of this study was to evaluate the systolic function of the left atrial appendage (LAA) in a group with and without patent foramen ovale (PFO) who suffered ischemic cerebrovascular events. Between September 2010 and October 2011, 17 patients were referred for transesophageal echocardiography (TEE) after suffering a stroke. PFO was defined as the passage of at least one bubble through atrial septum with bubble test. We compared systolic velocity in the appendage between patients with and without PFO and a control group. Were 8 women and 9 men, mean age 54.1 ± 19.5 years and 8 patients were under 55 years of age. All patients had suffered a ischemic cerebrovascular events, 41.2% had stroke, 52.9% transient ischemic attack and amaurosis fugax 5.9%. In the assessment of TEE, 11.8% had atrial septal aneurysm and 35.3% PFO. Mean LAA systolic velocity was 66.3 ± 20.3 cm / sec. There was no difference in systolic velocity of the LAA between patients with and without PFO (67.5 ± 11.8 cm / sec vs 65.7 ± 24.3 cm / sec respectively, p = 0.87). The control group of 8 patients, 5 women and 3 men, mean age 39.5 ± 18 years, had a LAA systolic velocity of 77.6 ± 28.9 cm / sec, no significant differences with ischemic patients. There were no differences in systolic function of the LAA between patients with and without PFO with ischemic cerebrovascular event.

  4. Left atrial dysfunction in patients with patent foramen ovale and atrial septal aneurysm: an alternative concurrent mechanism for arterial embolism?

    Science.gov (United States)

    Rigatelli, Gianluca; Aggio, Silvio; Cardaioli, Paolo; Braggion, Gabriele; Giordan, Massimo; Dell'avvocata, Fabio; Chinaglia, Mauro; Rigatelli, Giorgio; Roncon, Loris; Chen, Jack P

    2009-07-01

    We postulate that, in patients with large patent foramen ovales (PFO) and atrial septal aneurysms (ASA), left atrial (LA) dysfunction simulating "atrial fibrillation (AF)-like" pathophysiology might represent an alternate mechanism in the promotion of arterial embolism. Despite prior reports concerning paradoxical embolism through a PFO, the magnitude of this phenomenon as a risk factor for stroke remains undefined, because deep venous thrombosis is infrequently detected in such patients. To test our hypothesis, we prospectively enrolled 98 consecutive patients with previous stroke (mean age 37 +/- 12.5 years, 58 women) referred to our center for catheter-based PFO closure. Baseline values of LA passive and active emptying, LA conduit function, LA ejection fraction, and spontaneous echocontrast (SEC) in the LA and LA appendage were compared with those of 50 AF patients as well as a sex/age/cardiac risk-matched population of 70 healthy control subjects. Pre-closure PFO subjects demonstrated significantly greater reservoir function as well as passive and active emptying, with significantly reduced conduit function and LA ejection fraction, when compared with AF and control patients. Furthermore, in PFO patients, 66.3% (65 of 98) had moderate-to-severe ASA and basal shunt; SEC was observed in 52% of PFO plus ASA patients before closure. Multivariate stepwise logistic regression revealed moderate-to-severe ASA (odds ratio: 9.4, 95% confidence interval: 7.0 to 23.2, p < 0.001) as the most powerful predictor of LA dysfunction. After closure, all LA parameters normalized to the levels of control subjects: no SEC, device-related thrombosis, or aortic erosion were observed on follow-up echocardiography. This study suggests that moderate-to-severe ASA might be associated with LA dysfunction in patients with PFO. The resultant similarities to the pathophysiology of AF might represent an additional contributing mechanism for arterial embolism in such patients.

  5. Decreases in left atrial compliance during early-stage exercise are related to exercise intolerance in asymptomatic significant mitral stenosis.

    Science.gov (United States)

    Jung, Mi-Hyang; Jung, Hae Ok; Lee, Jung-Won; Youn, Ho-Joong

    2017-11-01

    Doppler-driven net atrioventricular compliance (C n ), which represents left atrial (LA) compliance, is an important determinant of pulmonary hypertension in mitral stenosis (MS). We hypothesized that decreases in C n during early-stage exercise underlie exercise intolerance in patients with MS. Thirty-three asymptomatic patients with significant MS (valve area 1.24 ± 0.16 cm 2 ) underwent resting and bicycle exercise echocardiography. LA compliance and conventional parameters were assessed at each workload. The patients were classified into two groups based on whether they developed dyspnea during exercise: an exercise-intolerance group (n = 22) and an exercise-tolerance group (n = 11). Moreover, "50 W" was defined as an early exercise stage. Although the groups had similar resting characteristics, there were striking differences in their echocardiographic parameters from the early stages of exercise. The relative C n decrease at 50 W (expressed as a percentage of the resting C n ) was significantly greater in the exercise-intolerance group (70.3 ± 15.4% vs 49.7 ± 9.7%, P intolerance group (P = .0005). Furthermore, differences in the trends in this parameter were observed between the two groups (P intolerance (adjusted OR 1.105, 95% CI 1.030-1.184) after adjustment for other conventional parameters. Decreases in C n during early-stage exercise are an important mechanism underlying exercise intolerance in MS. © 2017, Wiley Periodicals, Inc.

  6. Left atrial appendage segmentation and quantitative assisted diagnosis of atrial fibrillation based on fusion of temporal-spatial information.

    Science.gov (United States)

    Jin, Cheng; Feng, Jianjiang; Wang, Lei; Yu, Heng; Liu, Jiang; Lu, Jiwen; Zhou, Jie

    2018-05-01

    In this paper, we present an approach for left atrial appendage (LAA) multi-phase fast segmentation and quantitative assisted diagnosis of atrial fibrillation (AF) based on 4D-CT data. We take full advantage of the temporal dimension information to segment the living, flailed LAA based on a parametric max-flow method and graph-cut approach to build 3-D model of each phase. To assist the diagnosis of AF, we calculate the volumes of 3-D models, and then generate a "volume-phase" curve to calculate the important dynamic metrics: ejection fraction, filling flux, and emptying flux of the LAA's blood by volume. This approach demonstrates more precise results than the conventional approaches that calculate metrics by area, and allows for the quick analysis of LAA-volume pattern changes of in a cardiac cycle. It may also provide insight into the individual differences in the lesions of the LAA. Furthermore, we apply support vector machines (SVMs) to achieve a quantitative auto-diagnosis of the AF by exploiting seven features from volume change ratios of the LAA, and perform multivariate logistic regression analysis for the risk of LAA thrombosis. The 100 cases utilized in this research were taken from the Philips 256-iCT. The experimental results demonstrate that our approach can construct the 3-D LAA geometries robustly compared to manual annotations, and reasonably infer that the LAA undergoes filling, emptying and re-filling, re-emptying in a cardiac cycle. This research provides a potential for exploring various physiological functions of the LAA and quantitatively estimating the risk of stroke in patients with AF. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Epicardial clip occlusion of the left atrial appendage during cardiac surgery provides optimal surgical results and long-term stability.

    Science.gov (United States)

    Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr

    2017-07-01

    Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Optimal Analysis of Left Atrial Strain by Speckle Tracking Echocardiography: P-wave versus R-wave Trigger.

    Science.gov (United States)

    Hayashi, Shuji; Yamada, Hirotsugu; Bando, Mika; Saijo, Yoshihito; Nishio, Susumu; Hirata, Yukina; Klein, Allan L; Sata, Masataka

    2015-08-01

    Left atrial (LA) strain analysis using speckle tracking echocardiography is useful for assessing LA function. However, there is no established procedure for this method. Most investigators have determined the electrocardiographic R-wave peak as the starting point for LA strain analysis. To test our hypothesis that P-wave onset should be used as the starting point, we measured LA strain using 2 different starting points and compared the strain values with the corresponding LA volume indices obtained by three-dimensional (3D) echocardiography. We enrolled 78 subjects (61 ± 17 years, 25 males) with and without various cardiac diseases in this study and assessed global longitudinal LA strain by two-dimensional speckle tracking strain echocardiography using EchoPac software. We used either R-wave peak or P-wave onset as the starting point for determining LA strains during the reservoir (Rres, Pres), conduit (Rcon, Pcon), and booster pump (Rpump, Ppump) phases. We determined the maximum, minimum, and preatrial contraction LA volumes, and calculated the LA total, passive, and active emptying fractions using 3D echocardiography. The correlation between Pres and LA total emptying fraction was better than the correlation between Rres and LA total emptying fraction (r = 0.458 vs. 0.308, P = 0.026). Pcon and Ppump exhibited better correlation with the corresponding 3D echocardiographic parameters than Rcon (r = 0.560 vs. 0.479, P = 0.133) and Rpump (r = 0.577 vs. 0.345, P = 0.003), respectively. LA strain in any phase should be analyzed using P-wave onset as the starting point rather than R-wave peak. © 2014, Wiley Periodicals, Inc.

  9. Anatomical analysis of incidental left atrial diverticula in patients with suspected coronary artery disease using 64-channel multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S.Y. [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Kwon, S.H., E-mail: Kwon98@khu.ac.kr [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Oh, J.H. [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2011-10-15

    Aim: To describe and evaluate anatomical characterizations of incidental left atrial (LA) diverticula in patients with suspected coronary artery disease using 64-channel multidetector computed tomography (MDCT). Materials and methods: From October 2008 to June 2009, 2059 patients with suspected coronary artery disease underwent electrocardiogram-gated 64-channel MDCT. Five hundred and thirty-two LA diverticula were identified in 377 patients (18.3%, male to female ratio: 216:161, mean age 59 {+-} 10.89 years, range from 20 to 91 years). Two radiologists retrospectively analysed the number (single or multiple), size (diameter and length), shape (cystiform or tubiform), surface (smooth or irregular), and location (right or mid or left/upper or lower/lateral or posterior). If the length/diameter was <1.5, the diverticular shape was considered to be cystiform. Results: Among 532 LA diverticula, single (270/532, 51.1%), cystiform (411/532, 77.3%), and smooth (332/532, 62.4%) diverticula were found. The right upper region (255/532, 47.9%) was the most common location, followed by the left lateral area (172/532, 32.3%). The average diameter was 4.7 {+-} 2 mm (range from 1-19 mm), and the average length was 4.7 {+-} 2.1 mm (range 1-13 mm). The average ratio of length to diameter was 1.15 (range 0.25-1.45). The average number of diverticula was 2 {+-} 1.06 (range 1-5). Conclusion: Incidental LA diverticulum is not an uncommon finding in patients with suspected coronary artery disease. MDCT can provide anatomical details of LA diverticula. However, further studies are needed to determine their clinical significance.

  10. Prognostic value of left atrial function in systemic light-chain amyloidosis: a cardiac magnetic resonance study.

    Science.gov (United States)

    Mohty, Dania; Boulogne, Cyrille; Magne, Julien; Varroud-Vial, Nicolas; Martin, Sylvain; Ettaif, Hind; Fadel, Bahaa M; Bridoux, Frank; Aboyans, Victor; Damy, Thibaud; Jaccard, Arnaud

    2016-09-01

    Cardiac involvement in systemic light-chain amyloidosis (AL) imparts an adverse impact on outcome. The left atrium (LA), by virtue of its anatomical location and muscular wall, is commonly affected by the amyloid process. Although LA infiltration by amyloid fibrils leads to a reduction in its pump function, the infiltration of the left ventricular (LV) myocardium results in diastolic dysfunction with subsequent increase in filling pressures and LA enlargement. Even though left atrial volume (LAV) is an independent prognostic marker in many cardiomyopathies, its value in amyloid heart disease remains to be determined. In addition, few data are available as to the prognostic value of LA function in systemic AL. Using cardiac magnetic resonance (CMR), the current study aims to assess the prognostic significance of the maximal LAV and total LA emptying fraction (LAEF) in patients with AL. Fifty-four consecutive patients (age 66 ± 10 years, 59% males) with confirmed systemic AL and mean LV ejection fraction of 60 ± 12% underwent CMR. As compared with patients with no or minimal cardiac involvement (Mayo Clinic [MC] stage I), those at moderate and high risk (MC stages II and III) had significantly larger indexed maximal LAV (36 ± 15 vs. 46 ± 13 vs. 52 ± 19 mL/m(2), P = 0.03) and indexed minimal LAV (20 ± 6 vs. 34 ± 11 vs. 44 ± 17 mL/m(2), P 16% (37 ± 11 vs. 94 ± 4%, P = 0.001). In multivariate analysis, lower LAEF remained independently associated with a higher risk of 2-year mortality (HR = 1.08 per 1% decrease, 95% CI: 1.02-1.15, P = 0.003). In patients with systemic AL, LAEF as assessed by CMR is associated with NYHA functional class, MC stage, myocardial LGE and 2-year mortality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  11. Comparative effects of amlodipine and benazepril on left atrial pressure in dogs with experimentally-induced mitral valve regurgitation.

    Science.gov (United States)

    Suzuki, Shuji; Fukushima, Ryuji; Ishikawa, Taisuke; Yamamoto, Yuta; Hamabe, Lina; Kim, Soomin; Yoshiyuki, Rieko; Machida, Noboru; Tanaka, Ryou

    2012-09-18

    One of the purposes of treatment for dogs with mitral regurgitation (MR) is lowering left atrial pressure (LAP). There has been few study of the amlodipine in dogs with MR and amlodipine's effect on LAP has not been fully evaluated in a quantitative manner because of difficulties in directly measuring LAP. The objective of our study was to compare the short-term effects of amlodipine (0.2 mg/kg PO q12h) vs benazepril (0.5 mg/kg PO q12h), on LAP and echocardiographic parameters in five beagle dogs with experimentally-induced MR. LAP of eight dogs that has own control were measured using radiotelemetry system at baseline and again on days 1, 2, 3, 4, 5, 6, 7 of the drug administration. Mean LAP decreased significantly after amlodipine (11.20 ± 4.19 mmHg vs 14.61 ± 3.81 mmHg at baseline, p benazepril treatment (13.19 ± 3.47 mmHg, p > .05). LAP was lower after 7 days of amlodipine treatment than after 7 days of benazepril treatment. Significant reduction was seen for the first time 4 days after the administration amlodipine. The rate of the maximal area of the regurgitant jet signals to the left atrium area (ARJ/LAA) of the amlodipine treatment was significantly lower (p benazepril treatment. Although this study did not focus on adverse effects, amlodipine may be an effective drug for helping the patients with acute onset of severe MR, such as rupture of chordae tendinae or end stage patients were the LAP is likely to be elevated. Additional studies in clinical patients with degenerative mitral valve disease and acute chordal rupture are warranted because the blood-pressure lowering effects of amlodipine can decrease renal perfusion and this can further activate the RAAS.

  12. Total and interatrial epicardial adipose tissues are independently associated with left atrial remodeling in patients with atrial fibrillation.

    Science.gov (United States)

    Shin, Seung Yong; Yong, Hwan Seok; Lim, Hong Euy; Na, Jin Oh; Choi, Cheol Ung; Choi, Jong Il; Kim, Seong Hwan; Kim, Jin Won; Kim, Eung Ju; Park, Sang Weon; Rha, Seung-Woon; Park, Chang Gyu; Seo, Hong Seog; Oh, Dong Joo; Kim, Young-Hoon

    2011-06-01

    As epicardial adipose tissue (EAT) is a metabolically active visceral fat, potential interaction between EAT and myocardium is strongly suggested. The aims of this study were to determine whether the amount and regional distribution of EAT are related to the chronicity of atrial fibrillation (AF) and left atrial (LA) remodeling. This study consisted of 40 subjects with paroxysmal AF (PAF) and 40 with persistent AF (PeAF). Eighty subjects with no history of AF were enrolled as controls. Total volume of EAT (EAT(total)), regional thickness of EAT, and LA volume (LAV) were measured by multislice computed tomography. In the AF group, blood samples were drawn from coronary sinus for analysis of inflammatory cytokines including adiponectin. Compared with controls, AF subjects had larger LAV, EAT(total), and the thicknesses of periatrial EAT including interatrial septum (IAS). However, the thicknesses of periventricular EAT were not different between the groups. The PeAF subjects had larger LAV, EAT(total), and periatrial EAT thicknesses, higher levels of inflammatory cytokines, and lower level of adiponectin than did the PAF subjects. Adiponection level was significantly associated with EAT(total) and IAS thickness. Multivariate analysis revealed that EAT(total) (P = 0.004) and IAS thickness (P = 0.016) were independently associated with LAV. EAT(total) and thickness of periatrial EAT were significantly larger in AF subjects compared to those of the matched controls and were closely related to the chronicity of AF. Moreover, EAT(total) and IAS thickness were independently associated with LAV in subjects with AF. © 2011 Wiley Periodicals, Inc.

  13. The Value of 3D Printing Models of Left Atrial Appendage Using Real-Time 3D Transesophageal Echocardiographic Data in Left Atrial Appendage Occlusion: Applications toward an Era of Truly Personalized Medicine.

    Science.gov (United States)

    Liu, Peng; Liu, Rijing; Zhang, Yan; Liu, Yingfeng; Tang, Xiaoming; Cheng, Yanzhen

    The objective of this study was to assess the clinical feasibility of generating 3D printing models of left atrial appendage (LAA) using real-time 3D transesophageal echocardiogram (TEE) data for preoperative reference of LAA occlusion. Percutaneous LAA occlusion can effectively prevent patients with atrial fibrillation from stroke. However, the anatomical structure of LAA is so complicated that adequate information of its structure is essential for successful LAA occlusion. Emerging 3D printing technology has the demonstrated potential to structure more accurately than conventional imaging modalities by creating tangible patient-specific models. Typically, 3D printing data sets are acquired from CT and MRI, which may involve intravenous contrast, sedation, and ionizing radiation. It has been reported that 3D models of LAA were successfully created by the data acquired from CT. However, 3D printing of the LAA using real-time 3D TEE data has not yet been explored. Acquisition of 3D transesophageal echocardiographic data from 8 patients with atrial fibrillation was performed using the Philips EPIQ7 ultrasound system. Raw echocardiographic image data were opened in Philips QLAB and converted to 'Cartesian DICOM' format and imported into Mimics® software to create 3D models of LAA, which were printed using a rubber-like material. The printed 3D models were then used for preoperative reference and procedural simulation in LAA occlusion. We successfully printed LAAs of 8 patients. Each LAA costs approximately CNY 800-1,000 and the total process takes 16-17 h. Seven of the 8 Watchman devices predicted by preprocedural 2D TEE images were of the same sizes as those placed in the real operation. Interestingly, 3D printing models were highly reflective of the shape and size of LAAs, and all device sizes predicted by the 3D printing model were fully consistent with those placed in the real operation. Also, the 3D printed model could predict operating difficulty and the

  14. Ball clay

    Science.gov (United States)

    Virta, R.L.

    2001-01-01

    Part of the 2000 annual review of the industrial minerals sector. A general overview of the ball clay industry is provided. In 2000, sales of ball clay reached record levels, with sanitary ware and tile applications accounting for the largest sales. Ball clay production, consumption, prices, foreign trade, and industry news are summarized. The outlook for the ball clay industry is also outlined.

  15. Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Rettmann, Maryam E., E-mail: rettmann.maryam@mayo.edu; Holmes, David R.; Camp, Jon J.; Cameron, Bruce M.; Robb, Richard A. [Biomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, Minnesota 55905 (United States); Kwartowitz, David M. [Department of Bioengineering, Clemson University, Clemson, South Carolina 29634 (United States); Gunawan, Mia [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington D.C. 20057 (United States); Johnson, Susan B.; Packer, Douglas L. [Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905 (United States); Dalegrave, Charles [Clinical Cardiac Electrophysiology, Cardiology Division Hospital Sao Paulo, Federal University of Sao Paulo, 04024-002 Brazil (Brazil); Kolasa, Mark W. [David Grant Medical Center, Fairfield, California 94535 (United States)

    2014-02-15

    Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved

  16. Prognostic value of CT-derived left atrial and left ventricular measures in patients with acute chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, University Medical Center Utrecht (Netherlands); Vliegenthart, Rozemarijn [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); University of Groningen/University Medical Center Groningen, Center for Medical Imaging − North East Netherlands, Department of Radiology, Groningen (Netherlands); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Nance, John W. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Bamberg, Fabian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Abro, Joseph A. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Carr, Christine M. [Division of Emergency Medicine, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Litwin, Sheldon E. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); and others

    2017-01-15

    Highlights: • LV mass and LA diameter are independent prognostic factor for composite MACE. • LV mass and LA diameter were not significant prognostic factors for MACE in African Americans. • Assessment of LV mass by CT may have a role in the management of patients. - Abstract: Purpose: To determine which left atrial (LA) and left ventricular (LV) parameters are associated with future major adverse cardiac event (MACE) and whether these measurements have independent prognostic value beyond risk factors and computed tomography (CT)-derived coronary artery disease measures. Materials and methods: This retrospective analysis was performed under an IRB waiver and in HIPAA compliance. Subjects underwent coronary CT angiography (CCTA) using a dual-source CT system for acute chest pain evaluation. LV mass, LV ejection fraction (EF), LV end-systolic volume (ESV) and LV end-diastolic volume (EDV), LA ESV and LA diameter, septal wall thickness and cardiac chamber diameters were measured. MACE was defined as cardiac death, non-fatal myocardial infarction, unstable angina, or late revascularization. The association between cardiac CT measures and the occurrence of MACE was quantified using Cox proportional hazard analysis. Results: 225 subjects (age, 56.2 ± 11.2; 140 males) were analyzed, of whom 42 (18.7%) experienced a MACE during a median follow-up of 13 months. LA diameter (HR:1.07, 95%CI:1.01–1.13 per mm) and LV mass (HR:1.05, 95%CI:1.00–1.10 per g) remained significant prognostic factor of MACE after controlling for Framingham risk score. LA diameter and LV mass were also found to have prognostic value independent of each other. The other morphologic and functional cardiac measures were no significant prognostic factors for MACE. Conclusion: CT-derived LA diameter and LV mass are associated with future MACE in patients undergoing evaluation for chest pain, and portend independent prognostic value beyond traditional risk factors, coronary calcium score, and

  17. Comparative effects of amlodipine and benazepril on Left Atrial Pressure in Dogs with experimentally-induced Mitral Valve Regurgitation

    Directory of Open Access Journals (Sweden)

    Suzuki Shuji

    2012-09-01

    Full Text Available Abstract Background One of the purposes of treatment for dogs with mitral regurgitation (MR is lowering left atrial pressure (LAP. There has been few study of the amlodipine in dogs with MR and amlodipine’s effect on LAP has not been fully evaluated in a quantitative manner because of difficulties in directly measuring LAP. The objective of our study was to compare the short-term effects of amlodipine (0.2 mg/kg PO q12h vs benazepril (0.5 mg/kg PO q12h, on LAP and echocardiographic parameters in five beagle dogs with experimentally-induced MR. LAP of eight dogs that has own control were measured using radiotelemetry system at baseline and again on days 1, 2, 3, 4, 5, 6, 7 of the drug administration. Results Mean LAP decreased significantly after amlodipine (11.20 ± 4.19 mmHg vs 14.61 ± 3.81 mmHg at baseline, p  .05. LAP was lower after 7 days of amlodipine treatment than after 7 days of benazepril treatment. Significant reduction was seen for the first time 4 days after the administration amlodipine. The rate of the maximal area of the regurgitant jet signals to the left atrium area (ARJ/LAA of the amlodipine treatment was significantly lower (p  Conclusions LAP was significantly decreased after amlodipine treatment in dogs with surgically-induced MR but not after benazepril treatment. Although this study did not focus on adverse effects, amlodipine may be an effective drug for helping the patients with acute onset of severe MR, such as rupture of chordae tendinae or end stage patients were the LAP is likely to be elevated. Additional studies in clinical patients with degenerative mitral valve disease and acute chordal rupture are warranted because the blood-pressure lowering effects of amlodipine can decrease renal perfusion and this can further activate the RAAS.

  18. Left atrial passive emptying function is preserved in patients with permanent atrial fibrillation--a 320-slice multidetector computed tomography study

    DEFF Research Database (Denmark)

    Agner, Bue Fridolin Ross; Kühl, Jørgen Tobias; Kofoed, Klaus Fuglsang

    2014-01-01

    OBJECTIVE: Left atrial (LA) mechanical function is thought to be virtually inexistent in patients with permanent atrial fibrillation (AF). Due to recent advances in multidetector computed tomography (MDCT) technology, it is now possible to acquire images of the entire heart in a single heartbeat....... The objective of this study was to compare individual components of LA function assessed by MDCT in patients with permanent AF and patients in sinus rhythm (SR). METHODS: 320-slice MDCT was performed in 30 patients with permanent AF. Measurements of LA volumes during the cardiac cycle were compared to 30......; 71 vs. 30 ml/m(2), p permanent AF have significantly increased LA volumes throughout the cardiac...

  19. Percutaneous closure of the left atrial appendage with Watchman device: An option for patients with atrial fibrilation and high risk of bleeding with anticoagulation

    Directory of Open Access Journals (Sweden)

    Sénior, Juan

    2015-07-01

    Full Text Available Atrial fibrillation is the most common arrhythmia found in clinical practice, with a population prevalence of 1% to 2%. Anticoagulation remains a fundamental part of treatment for the prevention of cerebrovascular events (stroke, but it is contraindicated in approximately 20% of patients. We report a case of non-valvular atrial fibrillation with high-risk score for stroke, a history of intracerebral bleeding, and very high risk of bleeding with long-term anticoagulation. Percutaneous closure of the left atrial appendage with the Watchman device was performed successfully without complications.

  20. Measurement of left atrial volume by 2D and 3D non-contrast computed tomography compared with cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Fredgart, Maise Høigaard; Carter-Storch, Rasmus; Møller, Jacob Eifer

    2018-01-01

    Background: Cardiac magnetic resonance imaging (MRI) is considered the gold standard for assessment of left atrial (LA) volume. We assessed the feasibility of evaluating LA volume using 3D non-contrast computed tomography (NCCT). Furthermore, since manual tracing of LA volume is time consuming, we...... evaluated the accuracy of the LA area using 2D NCCT imaging for LA volume assessment. Methods: MRI and NCCT imaging were performed in 69 patients before and one year after aortic valve replacement. In 3D MRI and 3D NCCT, each slice was manually traced, excluding the pulmonary veins and atrial appendage...

  1. The New 3D Printed Left Atrial Appendage Closure with a Novel Holdfast Device: A Pre-Clinical Feasibility Animal Study.

    Directory of Open Access Journals (Sweden)

    M Brzeziński

    Full Text Available Many patients undergoing cardiac surgery have risk factors for both atrial fibrillation (AF and stroke. The left atrial appendage (LAA is the primary site for thrombi formation. The most severe complication of emboli derived from LAA is stroke, which is associated with a 12-month mortality rate of 38% and a 12-month recurrence rate of 17%. The most common form of treatment for atrial fibrillation and stroke prevention is the pharmacological therapy with anticoagulants. Nonetheless this form of therapy is associated with high risk of major bleeding. Therefore LAA occlusion devices should be tested for their ability to reduce future cerebral ischemic events in patients with high-risk of haemorrhage.The aim of this study was to evaluate the safety and feasibility of a novel left atrial appendage exclusion device with a minimally invasive introducer in a swine model.A completely novel LAA device, which is composed of two tubes connected together using a specially created bail, was designed using finite element modelling (FEM to obtain an optimal support force of 36 N at the closure line. The monolithic form of the occluder was obtained by using additive manufacturing of granular PA2200 powder with the technology of selective laser sintering (SLS. Fifteen swine were included in the feasibility tests, with 10 animals undergoing fourteen days of follow-up and 5 animals undergoing long-term observation of 3 months. For one animal, the follow-up was further prolonged to 6 months. The device was placed via minithoracotomy. After the observation period, all of the animals were euthanized, and their hearts were tested for LAA closure and local inflammatory and tissue response.After the defined observation period, all fifteen hearts were explanted. In all cases the full closure of the LAA was achieved. The macroscopic and microscopic evaluation of the explanted hearts showed that all devices were securely integrated in the surrounding tissues. No

  2. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  3. Three-dimensional speckle tracking echocardiography allows detailed evaluation of left atrial function in hypertrophic cardiomyopathy--insights from the MAGYAR-Path Study.

    Science.gov (United States)

    Domsik, Péter; Kalapos, Anita; Chadaide, Számi; Sepp, Róbert; Hausinger, Péter; Forster, Tamás; Nemes, Attila

    2014-11-01

    Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three-dimensional (3D) speckle tracking echocardiography (STE) has just been introduced for the evaluation of LA. This study was designed to compare 3DSTE-derived LA volumetric and strain parameters in HCM with healthy controls. The study comprised 23 consecutive HCM patients (mean age: 48.5 ± 15.1 years, 14 men). Their results were compared to 23 age- and gender-matched healthy controls. Complete two-dimensional Doppler echocardiography and 3DSTE have been performed in all cases. Calculated LA maximum (66.4 ± 20.4 mL vs. 36.0 ± 6.1 mL, P echocardiography allows detailed evaluation of LA (dys) function in HCM by volumetric and strain measurements. © 2014, Wiley Periodicals, Inc.

  4. Left atrial volume assessment in atrial fibrillation using multimodality imaging: a comparison of echocardiography, invasive three-dimensional CARTO and cardiac magnetic resonance imaging.

    Science.gov (United States)

    Rabbat, Mark G; Wilber, David; Thomas, Kevin; Malick, Owais; Bashir, Atif; Agrawal, Anoop; Biswas, Santanu; Sanagala, Thriveni; Syed, Mushabbar A

    2015-06-01

    Left atrial size in atrial fibrillation is a strong predictor of successful ablation and cardiovascular events. Cardiac magnetic resonance multislice method (CMR-MSM) is the current gold standard for left atrial volume (LAV) assessment but is time consuming. We investigated whether LAV with more rapid area-length method by echocardiography (Echo-AL) or cardiac magnetic resonance (CMR-AL) and invasive measurement by 3D-CARTO mapping during ablation correlate with the CMR-MSM. We studied 250 consecutive patients prior to atrial fibrillation ablation. CMR images were acquired on 3T scanner to measure LAV by MSM and biplane area-length method. Standard echocardiography views were used to calculate LAV by biplane area-length method. LAV during ablation was measured by 3D-CARTO mapping. LAV was compared using intra-class correlation (ICC), Pearson's correlation and Bland-Altman plots. CMR-MSM was used as the reference standard. Mean LAV using CMR-MSM was 112.7 ± 36.7 ml. CMR-AL method overestimated LAV by 13.3 ± 21.8 ml (11.2%, p atrial fibrillation. CMR-AL and 3D-CARTO correlated and agreed well with CMR-MSM (r = 0.87 and 0.74, ICC = 0.80 and 0.77 respectively). However, Echo-AL had poor correlation and agreement with CMR-MSM (r = 0.66 and ICC = 0.48). Bland-Altman plots confirmed these findings. CMR-AL method may be used as an alternative to CMR-MSM, as it is non-invasive, rapid, and correlates well with CMR-MSM. LAV by different modalities should not be used interchangeably.

  5. Cost-Effectiveness of Percutaneous Closure of the Left Atrial Appendage in Atrial Fibrillation Based on Results From PROTECT AF Versus PREVAIL.

    Science.gov (United States)

    Freeman, James V; Hutton, David W; Barnes, Geoffrey D; Zhu, Ruo P; Owens, Douglas K; Garber, Alan M; Go, Alan S; Hlatky, Mark A; Heidenreich, Paul A; Wang, Paul J; Al-Ahmad, Amin; Turakhia, Mintu P

    2016-06-01

    Randomized trials of left atrial appendage (LAA) closure with the Watchman device have shown varying results, and its cost effectiveness compared with anticoagulation has not been evaluated using all available contemporary trial data. We used a Markov decision model to estimate lifetime quality-adjusted survival, costs, and cost effectiveness of LAA closure with Watchman, compared directly with warfarin and indirectly with dabigatran, using data from the long-term (mean 3.8 year) follow-up of Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation (PROTECT AF) and Prospective Randomized Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation (PREVAIL) randomized trials. Using data from PROTECT AF, the incremental cost-effectiveness ratios compared with warfarin and dabigatran were $20 486 and $23 422 per quality-adjusted life year, respectively. Using data from PREVAIL, LAA closure was dominated by warfarin and dabigatran, meaning that it was less effective (8.44, 8.54, and 8.59 quality-adjusted life years, respectively) and more costly. At a willingness-to-pay threshold of $50 000 per quality-adjusted life year, LAA closure was cost effective 90% and 9% of the time under PROTECT AF and PREVAIL assumptions, respectively. These results were sensitive to the rates of ischemic stroke and intracranial hemorrhage for LAA closure and medical anticoagulation. Using data from the PROTECT AF trial, LAA closure with the Watchman device was cost effective; using PREVAIL trial data, Watchman was more costly and less effective than warfarin and dabigatran. PROTECT AF enrolled more patients and has substantially longer follow-up time, allowing greater statistical certainty with the cost-effectiveness results. However, longer-term trial results and postmarketing surveillance of major adverse events will be vital to determining the value of the Watchman in clinical

  6. Characteristics of Left Atrial Deformation Parameters and Their Prognostic Impact in Patients with Pathological Left Ventricular Hypertrophy: Analysis by Speckle Tracking Echocardiography.

    Science.gov (United States)

    Iio, Chiharuko; Inoue, Katsuji; Nishimura, Kazuhisa; Fujii, Akira; Nagai, Takayuki; Suzuki, Jun; Okura, Takafumi; Higaki, Jitsuo; Ogimoto, Akiyoshi

    2015-12-01

    The pathological process of left ventricular (LV) hypertrophy is associated with left atrial (LA) remodeling. This study was aimed to evaluate the prognostic value of LA strain parameters in patients with pathological LV hypertrophy. This study included 95 patients with hypertensive heart disease (HHD: n = 24), hypertrophic cardiomyopathy (HCM: n = 56), cardiac amyloidosis (CA: n = 15), and control subjects (n = 20). We used two-dimensional speckle tracking echocardiography (STE) to analyze LA global strain. LA electromechanical conduction time (EMT) at the septal (EMT-septal) and lateral wall (EMT-lateral), and their time difference (EMT-diff) were calculated. The incidence of cardiac death and heart failure hospitalization was defined as major cardiac events and that of atrial fibrillation as secondary outcome. Left atrial volume index was increased and LA booster strain was decreased in the HCM and CA groups compared with the HHD group. EMT-lateral was increased in the diseased groups compared with the control. EMT-diff was prolonged in the CA group compared with the HCM group. During the follow-up period (mean 3.4 years), major cardiac events and atrial fibrillation occurred in 17 and 13 patients, respectively. The occurrence of atrial fibrillation was associated with CA etiology, E/e', LA volume index, LAa, and EMT-lateral. The incidence of major cardiac events was independently correlated with LA volume index and EMT-diff in multivariate analysis. This study suggested that the EMT-diff could discriminate patients with a high risk of cardiac events among patients with pathological LV hypertrophy. © 2015, Wiley Periodicals, Inc.

  7. Left atrial and left ventricular diastolic function after the maze procedure for atrial fibrillation in mitral valve disease: degenerative versus rheumatic.

    Science.gov (United States)

    Kim, Hwan Wook; Moon, Mi Hyoung; Jo, Keon Hyun; Song, Hyun; Lee, Jae Won

    2015-02-01

    The present study was aimed to compare the left atrial and left ventricular diastolic functions amongst the rheumatic and degenerative mitral valve disease patients in atrial fibrillation who reverted to normal sinus rhythm following Cox-maze procedure. We prospectively investigated the left atrial and left ventricular function with Doppler echocardiography, by dividing into the rheumatic (N = 105) and the degenerative group (N = 47). Over the follow-up period (mean: 4.4 ± 1.2 years in the rheumatic group, 4.8 ± 1.3 years in the degenerative group), the rheumatic group showed statistically significant decrease in A' velocity and E' velocity, on contrary to degenerative group (A' velocity: mean decrease of 0.43 ± 0.13 cm/s in the rheumatic group, mean increase of 0.57 ± 0.11 cm/s in the degenerative group, p = 0.029, E' velocity: mean decrease of 0.23 ± 0.17 cm/s in the rheumatic group, mean increase of 0.21 ± 0.15 cm/s in the degenerative group, p = 0.031). In addition, the rheumatic group showed statistically significant increase in E/E' ratio than the degenerative group (mean increase of 4.49 ± 1.98 in the rheumatic group, mean increase of 1.74 ± 1.52 in the degenerative group, p = 0.047). Despite successful sinus rhythm restoration, the progressive loss of LA function as well as LV diastolic function is more prominent in the rheumatic group than the degenerative group. Therefore, differentiated strategies for postoperative surveillance are needed according to the pathology of mitral valve disease.

  8. In-treatment reduced left atrial diameter during antihypertensive treatment is associated with reduced new-onset atrial fibrillation in hypertensive patients with left ventricular hypertrophy: The LIFE Study

    DEFF Research Database (Denmark)

    Wachtell, Kristian; Gerdts, Eva; Aurigemma, Gerard P

    2010-01-01

    It is unclear whether improvement of left atrial (LA) and ventricular (LV) structure results in reduction in new-onset atrial fibrillation (AF). The aim of the present study was to examine whether changes in-treatment LA diameter were related to changes in risk of new-onset AF....

  9. Creation of a restrictive atrial communication in heart failure with preserved and mid-range ejection fraction: effective palliation of left atrial hypertension and pulmonary congestion.

    Science.gov (United States)

    Bauer, Anna; Khalil, Markus; Lüdemann, Monika; Bauer, Jürgen; Esmaeili, Anoosh; De-Rosa, Roberta; Voelkel, Norbert F; Akintuerk, Hakan; Schranz, Dietmar

    2018-04-16

    Left atrial decompression is considered in patients with symptomatic heart failure with preserved ejection fraction (HFpEF). We aimed to evaluate the feasibility and efficacy of transcatheter generation of a restrictive atrial septum communication to manage HFpEF from infancy to adulthood with cardiomyopathy and congenital heart defect. From June 2009 to December 2016, 24 patients (50% with an age less than 16 years) with HFpEF were palliated; NYHA-/Ross class IV (n = 10); median systemic ventricular ejection fraction 64 (range 35-78) %. Cardiomyopathy was classified as a restrictive (n = 4) or hypertrophic (n = 2). (75% related to congenital heart defects) Three patients had a systemic right ventricle; in the majority of patients, HFpEF was associated to complex congenital heart defects (n = 18). Mean pulmonary arterial pressures (PAP systolic/diastolic) were 56/28 (± 24/13), left atrial pressures (LAP, v-, a-wave, mean) 26/25/20 (± 7/10/6). Trans-septal puncture was used in 22 patients; foramen ovale dilatation in 2 patients. Median balloon size was 12 (range 6-18) mm; procedure time including diagnostic measures 125 (83-221) min. No procedural death or complications were observed. Mean LA-pressures decreased significantly to 19/19/15 ± 6/8/5 mmHg (p = 0.05); median brain natriuretic peptide (BNP) decreased from 392 (range 93-4401) pg/ml median BNP to 314 (range 61-1544) pg/ml (p = 0.05). Three patients died; one patient received orthotopic heart and one patient a heart-lung transplantation. No patient required so far an assist device. Clinical improvement occurred in all patients, in some after additional surgical or interventional approach. Transcatheter LA decompression is an age-independent, effective palliation treating patients with HFpEF.

  10. Golf Ball

    Science.gov (United States)

    1998-01-01

    The Ultra 500 Series golf balls, introduced in 1995 by Wilson Sporting Goods Company, has 500 dimples arranged in a pattern of 60 spherical triangles. The design employs NASA's aerodynamics technology analysis of air loads of the tank and Shuttle orbiter that was performed under the Space Shuttle External Tank program. According to Wilson, this technology provides 'the most symmetrical ball surface available, sustaining initial velocity longer and producing the most stable ball flight for unmatched accuracy and distance.' The dimples are in three sizes, shapes and depths mathematically positioned for the best effect. The selection of dimples and their placement optimizes the interaction of opposing forces of lift and drag. Large dimples reduce air drag, enhance lift, and maintain spin for distance. Small dimples prevent excessive lift that destabilizes the ball flight and the medium size dimples blend the other two.

  11. Radiopharmaceuticals for thrombus detection

    International Nuclear Information System (INIS)

    Knight, L.C.

    1990-01-01

    Most of the components of the thrombotic and fibrinolytic systems have at some time been evaluated as a means of carrying a radiolabel specifically to thrombi, although very few have been promising enough to emerge from investigational status to routine clinical use. New approaches are being explored, including improved methods of labeling platelets, chemically modified forms of previously tested plasma proteins, and new biomolecules, including monoclonal antibodies specific for fibrin and platelets. The current goal is to find one or more radiotracers that bind specifically and rapidly to thrombi, and that also have a rapid blood disappearance rate, permitting a clear diagnosis within a few hours after injection. Because this test may be needed to assess the course of therapy in an anticoagulated patient, the ideal radiopharmaceutical should be able to locate thrombi without interference by anticoagulants. Until a suitable thrombus-specific radiopharmaceutical becomes generally available, many hospitals will continue to attempt to make a diagnosis with nonspecific radiopharmaceuticals that can at best provide blood pool images to indicate filling defects. Several of the new approaches seem likely to provide the radiopharmaceutical sought, although clinical trials are at an early stage.137 references

  12. Thrombus aspiration catheter is a Dottering balloon

    Directory of Open Access Journals (Sweden)

    D. Sheshagiri Rao

    2016-07-01

    Full Text Available Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate?

  13. Thrombus aspiration catheter is a Dottering balloon.

    Science.gov (United States)

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate? Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  14. Left ventricular outflow tract to left atrial communication secondary to rupture of mitral-aortic intervalvular fibrosa in infective endocarditis: diagnosis by transesophageal echocardiography and color flow imaging.

    Science.gov (United States)

    Bansal, R C; Graham, B M; Jutzy, K R; Shakudo, M; Shah, P M

    1990-02-01

    Infection of the mitral-aortic intervalvular fibrosa occurs most commonly in association with infective endocarditis of the aortic valve. Infection of the aortic valve results in a regurgitant jet that presumably strikes this subaortic interannular zone of fibrous tissue and produces a secondary site of infection. Infection of this interannular zone then leads to the formation of subaortic abscess or pseudoaneurysm of the left ventricular outflow tract. This infected zone of mitral-aortic intervalvular fibrosa or subaortic aneurysm can subsequently rupture into the left atrium with systolic ejection of blood from the left ventricular outflow tract to the left atrium. This report describes the echocardiographic findings in three patients with pathologically proved left ventricular outflow tract to left atrial communication. Precise preoperative diagnosis is important, and this lesion should be differentiated from ruptured aneurysm of the sinus of Valsalva and perforation of the anterior mitral leaflet. Transthoracic echocardiography using color flow imaging and conventional Doppler techniques may show an eccentric mitral regurgitation type of signal in the left atrium originating from the region of the left ventricular outflow tract. However, transesophageal echocardiography provides an accurate preoperative diagnosis and should be used intraoperatively during repair of such lesions.

  15. Epicardial fat thickness correlates with P-wave duration, left atrial size and decreased left ventricular systolic function in morbid obesity.

    Science.gov (United States)

    Fernandes-Cardoso, A; Santos-Furtado, M; Grindler, J; Ferreira, L A; Andrade, J L; Santo, M A

    2017-08-01

    Epicardial fat (EF) is increased in obesity and has important interactions with atrial and ventricular myocardium. Most of the evidence in this scenario can be confused by the presence of comorbidities such as hypertension, diabetes and dyslipidemia, which are very common in this population. The influence of EF on atrial remodeling and cardiac function demands further investigation on morbidly obese without these comorbidities. We prospectively recruited 20 metabolically healthy morbidly obese and 20 normo-weights controls. The maximum P-wave duration (PWD) was analyzed by 12-lead electrocardiogram. Left atrial diameter (LAD), left ventricular ejection fraction (LVEF) and EF thickness (EFT) were evaluated by two-dimensional echocardiography. The mean of maximum PWD and LAD were significantly larger in the obese group as compared to the control group: 109.55 ± 11.52 ms × 89.38 ± 11.19 ms and 36.12 ± 3.46 mm × 31.45 ± 2.64 mm, (p function. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  16. Left atrial appendage occlusion with Amplatzer Cardio Plug is an acceptable therapeutic option for prevention of stroke recurrence in patients with non-valvular atrial fibrillation and contraindication or failure of oral anticoagulation with acenocumarol

    OpenAIRE

    Hawkes, Maximiliano A.; Pertierra, Lucía; Rodriguez-Lucci, Federico; Pujol-Lereis, Virginia A.; Ameriso, Sebastián F.

    2016-01-01

    ABSTRACT Left atrial appendage occlusion (LAAO) appears as a therapeutic option for some atrial fibrillation patients not suitable for oral anticoagulation because an increased hemorrhagic risk or recurrent ischemic events despite anticoagulant treatment. Methods Report of consecutive atrial fibrillation patients treated with LAAO with Amplatzer Cardio Plug because contraindication or failure of oral anticoagulation with acenocumarol. CHA2DS2VASC, HAS-BLED, NIHSS, mRS, procedural complicati...

  17. Echocardiographic predictors of early in-hospital heart failure during first ST-elevation acute myocardial infarction: does myocardial performance index and left atrial volume improve diagnosis over conventional parameters of left ventricular function?

    Directory of Open Access Journals (Sweden)

    Machado Cristiano V

    2011-06-01

    Full Text Available Abstract Background Left ventricular ejection fraction (LVEF has been considered a major determinant of early outcome in acute myocardial infarction (AMI. Myocardial performance index (MPI has been associated to early evolution in AMI in a heterogeneous population, including non ST-elevation or previous AMI. Left atrial volume has been related with late evolution after AMI. We evaluated the independent role of clinical and echocardiographic variables including LVEF, MPI and left atrial volume in predicting early in-hospital congestive heart failure (CHF specifically in patients with a first isolated ST-elevation AMI. Methods Echocardiography was performed within 30 hours of chest pain in 95 patients with a first ST-elevation AMI followed during the first week of hospitalization. Several clinical and echocardiographic variables were analyzed. CHF was defined as Killip class ≥ II. Multivariate regression analysis was used to select independent predictor of in-hospital CHF. Results Early in-hospital CHF occurred in 29 (31% of patients. LVEF ≤ 0.45 was the single independent and highly significant predictor of early CHF among other clinical and echocardiographic variables (odds ratio 17.0; [95% CI 4.1 - 70.8]; p Conclusion For patients with first, isolated ST-elevation AMI, LVEF assessed by echocardiography still constitutes a strong and accurate independent predictor of early in-hospital CHF, superior to isolated MPI and left atrial volume in this particular subset of patients.

  18. Adding left atrial appendage closure to open heart surgery provides protection from ischemic brain injury six years after surgery independently of atrial fibrillation history: the LAACS randomized study.

    Science.gov (United States)

    Park-Hansen, Jesper; Holme, Susanne J V; Irmukhamedov, Akhmadjon; Carranza, Christian L; Greve, Anders M; Al-Farra, Gina; Riis, Robert G C; Nilsson, Brian; Clausen, Johan S R; Nørskov, Anne S; Kruuse, Christina R; Rostrup, Egill; Dominguez, Helena

    2018-05-23

    Open heart surgery is associated with high occurrence of atrial fibrillation (AF), subsequently increasing the risk of post-operative ischemic stroke. Concomitant with open heart surgery, a cardiac ablation procedure is commonly performed in patients with known AF, often followed by left atrial appendage closure with surgery (LAACS). However, the protective effect of LAACS on the risk of cerebral ischemia following cardiac surgery remains controversial. We have studied whether LAACS in addition to open heart surgery protects against post-operative ischemic brain injury regardless of a previous AF diagnosis. One hundred eighty-seven patients scheduled for open heart surgery were enrolled in a prospective, open-label clinical trial and randomized to concomitant LAACS vs. standard care. Randomization was stratified by usage of oral anticoagulation (OAC) planned to last at least 3 months after surgery. The primary endpoint was a composite of post-operative symptomatic ischemic stroke, transient ischemic attack or imaging findings of silent cerebral ischemic (SCI) lesions. During a mean follow-up of 3.7 years, 14 (16%) primary events occurred among patients receiving standard surgery vs. 5 (5%) in the group randomized to additional LAACS (hazard ratio 0.3; 95% CI: 0.1-0.8, p = 0.02). In per protocol analysis (n = 141), 14 (18%) primary events occurred in the control group vs. 4 (6%) in the LAACS group (hazard ratio 0.3; 95% CI: 0.1-1.0, p = 0.05). In a real-world setting, LAACS in addition to elective open-heart surgery was associated with lower risk of post-operative ischemic brain injury. The protective effect was not conditional on AF/OAC status at baseline. LAACS study, clinicaltrials.gov NCT02378116 , March 4th 2015, retrospectively registered.

  19. Left Atrial Deformation Analysis in Patients with Corrected Tetralogy of Fallot by 3D Speckle-Tracking Echocardiography (from the MAGYAR-Path Study

    Directory of Open Access Journals (Sweden)

    Kálmán Havasi

    Full Text Available Abstract Background: Three-dimensional (3D echocardiography coupled with speckle-tracking echocardiographic (STE capability is a novel methodology which has been demontrated to be useful for the assessment of left atrial (LA volumes and functional properties. There is increased scientific interest on myocardial deformation analysis in adult patients with corrected tetralogy of Fallot (cTOF. Objectives: To compare LA volumes, volume-based functional properties and strain parameters between cTOF patients and age- and gender-matched healthy controls. Methods: The study population consisted of 19 consecutive adult patients with cTOF in sinus rhythm nursing at the University of Szeged, Hungary (mean age: 37.9 ± 11.3 years, 8 men, who had repair at the age of 4.1 ± 2.5 years. They all had undergone standard transthoracic two-dimensional Doppler echocardiographic study extended with 3DSTE. Their results were compared to 23 age- and gender-matched healthy controls (mean age: 39.2 ± 10.6 years, 14 men. Results: Increased LA volumes and reduced LA emptying fractions respecting cardiac cycle could be demonstrated in cTOF patients compared to controls. LA stroke volumes featuring all LA functions showed no differences between the 2 groups examined. LA global and mean segmental uni- and multidirectional peak strains featuring LA reservoir function were found to be diminished in adult patients with cTOF as compared to controls. Similarly to peak strains reduced global and mean segmental LA strains at atrial contraction characterizing atrial booster pump function could be demonstrated in cTOF patients as compared to controls. Conclusions: Significant deterioration of all LA functions could be demonstrated in adult patients with cTOF late after repair.

  20. Assessment of ventriculo-vascular properties in repaired coarctation using cardiac magnetic resonance-derived aortic, left atrial and left ventricular strain

    Energy Technology Data Exchange (ETDEWEB)

    Shang, Quanliang [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Central South University, Department of Radiology, Second Xiangya Hospital, Changsha, Hunan Province (China); Sarikouch, Samir; Beerbaum, Philipp [Hannover Medical School, Hannover (Germany); Patel, Shivani; Danford, David A.; Kutty, Shelby [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Schuster, Andreas [Department of Cardiology and Pneumonology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Steinmetz, Michael [Department of Pediatric Cardiology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Ou, Phalla [University Paris Diderot, Department of Radiology, Hospital Bichat, APHP, Paris (France)

    2017-01-15

    In patients with repaired coarctation of aorta (CoA), we assessed ventriculo-vascular characteristics using CMR-derived aortic area strain (AAS), left atrial (LA) and left ventricular (LV) longitudinal and circumferential strain (LS, CS). Seventy-five subjects including 50 with repaired CoA divided into hypertensive (n = 25), normotensive (n = 25) and 25 controls were studied. AAS was measured at 3 levels: ascending aorta, proximal descending and descending aorta. LA and LV LS were measured using CMR-feature tracking. LA and LV end-diastolic volumes, ejection fraction (EF) and mass were measured. Mean patient age was 19.7 ± 6.7 and controls 23 ± 15 (years). All strains (LA, LV, ascending and descending aortic) were lower in CoA subgroups compared to controls except the AAS at diaphragm, which was not different. Comparisons between hypertensive and normotensive CoA showed no differences in LV mass, LV volumetric indices, and LA and LV strain indices; however, ascending AAS was lower in hypertensive subgroup (p = 0.02). Ascending AAS was correlated with LV mass (r = -0.4, p = 0.005), LVEF (r = -0.4, p = 0.004), systolic blood pressure (r = -0.5, p = 0.0001) and LVLS (r = 0.5, p = 0.001). Ascending AAS correlated with LV mass, EF and LVLS. In hypertensive CoA, ascending AAS was reduced compared to normotensive CoA and controls, indicating vascular remodelling differences influenced by ongoing hypertension. (orig.)

  1. Left Atrial Deformation Analysis in Patients with Corrected Tetralogy of Fallot by 3D Speckle-Tracking Echocardiography (from the MAGYAR-Path Study)

    Science.gov (United States)

    Havasi, Kálmán; Domsik, Péter; Kalapos, Anita; McGhie, Jackie S.; Roos-Hesselink, Jolien W.; Forster, Tamás; Nemes, Attila

    2017-01-01

    Background Three-dimensional (3D) echocardiography coupled with speckle-tracking echocardiographic (STE) capability is a novel methodology which has been demontrated to be useful for the assessment of left atrial (LA) volumes and functional properties. There is increased scientific interest on myocardial deformation analysis in adult patients with corrected tetralogy of Fallot (cTOF). Objectives To compare LA volumes, volume-based functional properties and strain parameters between cTOF patients and age- and gender-matched healthy controls. Methods The study population consisted of 19 consecutive adult patients with cTOF in sinus rhythm nursing at the University of Szeged, Hungary (mean age: 37.9 ± 11.3 years, 8 men, who had repair at the age of 4.1 ± 2.5 years). They all had undergone standard transthoracic two-dimensional Doppler echocardiographic study extended with 3DSTE. Their results were compared to 23 age- and gender-matched healthy controls (mean age: 39.2 ± 10.6 years, 14 men). Results Increased LA volumes and reduced LA emptying fractions respecting cardiac cycle could be demonstrated in cTOF patients compared to controls. LA stroke volumes featuring all LA functions showed no differences between the 2 groups examined. LA global and mean segmental uni- and multidirectional peak strains featuring LA reservoir function were found to be diminished in adult patients with cTOF as compared to controls. Similarly to peak strains reduced global and mean segmental LA strains at atrial contraction characterizing atrial booster pump function could be demonstrated in cTOF patients as compared to controls. Conclusions Significant deterioration of all LA functions could be demonstrated in adult patients with cTOF late after repair. PMID:28327874

  2. Low Left Atrial Compliance Contributes to the Clinical Recurrence of Atrial Fibrillation after Catheter Ablation in Patients with Structurally and Functionally Normal Heart.

    Science.gov (United States)

    Park, Junbeom; Yang, Pil-sung; Kim, Tae-Hoon; Uhm, Jae-Sun; Kim, Joung-Youn; Joung, Boyoung; Lee, Moon-Hyoung; Hwang, Chun; Pak, Hui-Nam

    2015-01-01

    Stiff left atrial (LA) syndrome was initially reported in post-cardiac surgery patients and known to be associated with low LA compliance. We investigated the physiological and clinical implications of LA compliance by estimating LA pulse pressure (LApp) among patients with atrial fibrillation (AF) and structurally and functionally normal heart. Among 1038 consecutive patients with LA pressure measurements before AF ablation, we included 334 patients with structurally and functionally normal heart (81.7% male, 54.1±10.6 years, 77.0% paroxysmal AF) after excluding those with hypertension, diabetes, and previous ablation or cardiac surgery. We measured LApp (peak-nadir LA pressure) at the beginning of the ablation procedure and compared the values with clinical parameters and the AF recurrence rate. AF patients with normal heart were younger and more frequently male and had paroxysmal AF, a lower body mass index, and a lower LApp compared to others (all p<0.05). Based on the median value, the low LA compliance group (LApp≥13 mmHg) had a smaller LA volume index and lower LA voltage (all p<0.05) compared to the high LA compliance group. During a mean follow-up of 16.7±11.8 months, low LA compliance was independently associated with two fold-higher risk of clinical AF recurrence (HR:2.202; 95%CI:1.077-4.503; p = 0.031). Low LA compliance, as determined by an elevated LApp, was associated with a smaller LA volume index and lower LA voltage and independently associated with higher clinical recurrence after catheter ablation in AF patients with structurally and functionally normal heart.

  3. Angiotensin converting enzyme 2 activity and human atrial fibrillation: increased plasma angiotensin converting enzyme 2 activity is associated with atrial fibrillation and more advanced left atrial structural remodelling.

    Science.gov (United States)

    Walters, Tomos E; Kalman, Jonathan M; Patel, Sheila K; Mearns, Megan; Velkoska, Elena; Burrell, Louise M

    2017-08-01

    Angiotensin converting enzyme 2 (ACE2) is an integral membrane protein whose main action is to degrade angiotensin II. Plasma ACE2 activity is increased in various cardiovascular diseases. We aimed to determine the relationship between plasma ACE2 activity and human atrial fibrillation (AF), and in particular its relationship to left atrial (LA) structural remodelling. One hundred and three participants from a tertiary arrhythmia centre, including 58 with paroxysmal AF (PAF), 20 with persistent AF (PersAF), and 25 controls, underwent clinical evaluation, echocardiographic analysis, and measurement of plasma ACE2 activity. A subgroup of 20 participants underwent invasive LA electroanatomic mapping. Plasma ACE2 activity levels were increased in AF [control 13.3 (9.5-22.3) pmol/min/mL; PAF 16.9 (9.7-27.3) pmol/min/mL; PersAF 22.8 (13.7-33.4) pmol/min/mL, P = 0.006]. Elevated plasma ACE2 was associated with older age, male gender, hypertension and vascular disease, elevated left ventricular (LV) mass, impaired LV diastolic function and advanced atrial disease (P < 0.05 for all). Independent predictors of elevated plasma ACE2 activity were AF (P = 0.04) and vascular disease (P < 0.01). There was a significant relationship between elevated ACE2 activity and low mean LA bipolar voltage (adjusted R2 = 0.22, P = 0.03), a high proportion of complex fractionated electrograms (R2 = 0.32, P = 0.009) and a long LA activation time (R2 = 0.20, P = 0.04). Plasma ACE2 activity is elevated in human AF. Both AF and vascular disease predict elevated plasma ACE2 activity, and elevated plasma ACE2 is significantly associated with more advanced LA structural remodelling. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  4. Prospective randomized evaluation of the watchman left atrial appendage closure device in patients with atrial fibrillation versus long-term warfarin therapy: The PREVAIL trial.

    Science.gov (United States)

    Belgaid, Djouhar Roufeida; Khan, Zara; Zaidi, Mariam; Hobbs, Adrian

    2016-09-15

    Assessing the safety and effectiveness of left atrial appendage (LAA) (pouch found in the upper chambers of the heart) occlusion, using the Watchman device compared to long term warfarin therapy (drug that reduces clot formation), in preventing the risk of stroke in patients with atrial fibrillation (most common type of irregular heart beat). 90% of strokes in atrial fibrillation arise from clots forming in this pouch. By mechanically blocking it using the device less clots are suggested to be formed. This is an alternative to taking warfarin especially in patients who cannot take it. 50 sites in the United States enrolled 407 participants. After being randomly allocated, the device group had 269 participants and warfarin group (comparator)had 138 participants. Patients with atrial fibrillation and at high risk of stroke were randomly allocated a group after they were deemed eligible. Patients in the device group had to take warfarin and aspirin for 45days till the complete closure of the LAA. The oral anticoagulant was followed by dual antiplatelet therapy until 6months and then ASA. Patients in the warfarin group have to take it for life and were continually monitored. The study ran for 26months. The trial assessed the rate of adverse events using three endpoints: The PREVAIL trial was not designed to show superiority, but non-inferiority. It met the safety endpoint and one efficacy endpoint for the watchman device compared to long term warfarin for overall efficacy of the device. The results established that LAA occlusion is not worse than warfarin intake for the prevention of stroke more than 1week after randomization. Compared to previous trials, the safety of the device has also improved. LAA occlusion is a reasonable alternative to chronic warfarin therapy in stroke prevention for patients with atrial fibrillation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Cost-Effectiveness of Percutaneous Closure of the Left Atrial Appendage in Atrial Fibrillation Based on Results from PROTECT AF vs. PREVAIL

    Science.gov (United States)

    Freeman, James V.; Hutton, David W.; Barnes, Geoffrey D.; Zhu, Ruo P.; Owens, Douglas K.; Garber, Alan M.; Go, Alan S.; Hlatky, Mark A.; Heidenreich, Paul A.; Wang, Paul J.; Al-Ahmad, Amin; Turakhia, Mintu P.

    2016-01-01

    Background Randomized trials of left atrial appendage (LAA) closure with the Watchman device have shown varying results, and its cost-effectiveness compared to anticoagulation has not been evaluated using all available contemporary trial data. Methods and Results We used a Markov decision model to estimate lifetime quality-adjusted survival, costs, and cost-effectiveness of LAA closure with Watchman, compared directly with warfarin and indirectly with dabigatran, using data from the long-term (mean 3.8 year) follow-up of PROTECT AF and PREVAIL randomized trials. Using data from PROTECT AF, the incremental cost-effectiveness ratios (ICER) compared to warfarin and dabigatran were $20,486 and $23,422 per quality adjusted life year (QALY), respectively. Using data from PREVAIL, LAA closure was dominated by warfarin and dabigatran, meaning that it was less effective (8.44, 8.54, and 8.59 QALYs, respectively) and more costly. At a willingness-to-pay-threshold of $50,000 per QALY, LAA closure was cost-effective 90% and 9% of the time under PROTECT AF and PREVAIL assumptions, respectively. These results were sensitive to the rates of ischemic stroke and intracranial hemorrhage for LAA closure and medical anticoagulation. Conclusions Using data from the PROTECT AF trial, LAA closure with the Watchman device was cost-effective; using PREVAIL trial data, Watchman was more costly and less effective than warfarin and dabigatran. PROTECT AF enrolled more patients and has substantially longer follow-up time, allowing greater statistical certainty with the cost-effectiveness results. However, longer term trial results and post-marketing surveillance of major adverse events will be vital to determining the value of the Watchman in clinical practice. PMID:27307517

  6. Comparison of determinations of left atrial volume by the biplane area-length and Simpson's methods using 64-slice computed tomography

    International Nuclear Information System (INIS)

    Takagi, Yasuhiro; Ehara, Shoichi; Okuyama, Takuhiro

    2009-01-01

    There is increasing evidence that left atrial (LA) size is an important predictor of adverse cardiovascular outcomes such as atrial fibrillation, stroke, and congestive heart failure. The aim of this study was to determine whether there is a difference in results of quantification of LA volume by the area-length and Simpson's methods using multislice computed tomography (MSCT). The study population consisted of 51 patients with sinus rhythm (sinus group) and 20 patients with atrial fibrillation (af group) clinically indicated for MSCT angiography for evaluation of coronary arteries. Maximum LA volume, obtained at end-systole from the phase immediately preceding mitral valve opening, was measured using the area-length and Simpson's methods. In the sinus group, the mean LA volumes, indexed to body surface area, were 48.4±17.9 ml/m 2 with the area-length method and 48.3±17.0 ml/m 2 with the Simpson's method. In the af group, the mean indexed LA volumes with the area-length method and the Simposon's method were 91.5±47.5 ml/m 2 and 90.3±45.9 ml/m 2 , respectively. LA volumes calculated by the area-length method exhibited a strong linear relationship and agreement with those calculated using Simpson's method in both the groups (sinus group: r=0.99, P<0.0001, af group: r=0.99, P<0.0001). The area-length method is a simple and reproducible means of assessment of LA volume. Standardization of LA volume assessment using MSCT is important for serial follow-up and meaningful communication of results of testing among institutions and physicians. (author)

  7. Left atrial appendage occlusion for stroke prevention in patients with atrial fibrillation: a systematic review and network meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Hanif, Hasib; Belley-Cote, Emilie P; Alotaibi, Abdullah; Dvirnik, Nazari; Neupane, Binod; Beyene, Joseph; Eikelboom, John W; Holmes, David; Whitlock, Richard P

    2018-02-01

    Atrial fibrillation (AF) is one of the leading causes of stroke. Risks associated with oral anticoagulation (OAC) limit adherence to recommended therapy. Left atrial appendage (LAA) occlusion is a treatment alternative in patients with AF. We performed a network meta-analysis (NMA) of randomized trials evaluating the efficacy of LAA occlusion compared with oral anticoagulant, antiplatelet, and placebo for stroke prevention. We also assessed the impact of LAA occlusion on mortality, major bleeding, and operative time. We searched MEDLINE, EMBASE, PubMed, and Cochrane Library for randomized trials comparing percutaneous or surgical LAA occlusion with standard of care in AF patients. Conventional meta-analysis found no difference between groups for stroke (5 trials, 1285 patients;RR 0.78, 95% CI 0.47-1.29), and a significant reduction in mortality (5 trials, 1285 patients; RR 0.71, 95% CI 0.51-0.99) favouring LAA occlusion. NMA demonstrated a trend towards reduction in stroke (OR 0.84, 95% CrI 0.47-1.55) and mortality (OR 0.69, 95% CrI 0.44-1.10) for LAA occlusion versus warfarin, but no statistically significant effect. Statistical ranking curves placed LAA occlusion as the most efficacious treatment on the outcomes of stroke and mortality when compared to warfarin, aspirin, or placebo. No significant differences between groups were seen in major bleeding or operative time for surgical trials. The overall quality of the evidence was low as assessed by GRADE. LAA occlusion appears to preserve the benefits of OAC therapy for stroke prevention in patients with AF, but the current evidence is of low quality.

  8. Left atrial volume index as a predictor for persistent left ventricular dysfunction after aortic valve surgery in patients with chronic aortic regurgitation: the role of early postoperative echocardiography.

    Science.gov (United States)

    Cho, In-Jeong; Chang, Hyuk-Jae; Hong, Geu-Ru; Heo, Ran; Sung, Ji Min; Lee, Sang-Eun; Chang, Byung-Chul; Shim, Chi Young; Ha, Jong-Won; Chung, Namsik

    2015-06-01

    This study aimed to explore whether echocardiographic measurements during the early postoperative period can predict persistent left ventricular systolic dysfunction (LVSD) after aortic valve surgery in patients with chronic aortic regurgitation (AR). We prospectively recruited 54 patients (59 ± 12 years) with isolated chronic severe AR who subsequently underwent aortic valve surgery. Standard transthoracic echocardiography was performed before the operation, during the early postoperative period (≤2 weeks), and then 1 year after the surgery. Twelve patients with preoperative LVSD demonstrated LVSD at early after the surgery. Of the 42 patients without LVSD at preoperative echocardiography, 15 patients (36%) developed early postoperative LVSD after surgical correction. All 27 patients without LVSD at early postoperative echocardiography maintained LV function at 1 year after surgery. In the other 27 patients with postoperative LVSD, 17 patients recovered from LVSD and 10 patients did not at 1 year after surgery. Multiple logistic analysis demonstrated that postoperative left atrial volume index (LAVI) was the only independent predictor for persistent LVSD at 1 year after surgery in patients with postoperative LVSD (OR 1.180, 95% CI, 1.003-1.390, P = 0.046). The optimal LAVI cutoff value (>34.9 mL/m(2) ) had a sensitivity of 80% and a specificity of 88% for the prediction of persistent LVSD. Prevalence of early postoperative LVSD was relatively high, even in the patients without LVSD at preoperative echocardiography. Postoperative LAVI could be useful to predict persistent LVSD after aortic valve surgery in patients with early postoperative LVSD. © 2014, Wiley Periodicals, Inc.

  9. - LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography

    International Nuclear Information System (INIS)

    Behnes, Michael; Akin, Ibrahim; Sartorius, Benjamin; Fastner, Christian; El-Battrawy, Ibrahim; Borggrefe, Martin; Haubenreisser, Holger; Meyer, Mathias; Schoenberg, Stefan O.; Henzler, Thomas

    2016-01-01

    A standardized imaging proposal evaluating implanted left atrial appendage (LAA) occlusion devices by cardiac computed tomography angiography (cCTA) has never been investigated. cCTA datasets were acquired on a 3 rd generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. An interdisciplinary evaluation was performed by two interventional cardiologists and one radiologist on a 3D multi-planar workstation. A standardized multi-planar reconstruction algorithm was developed in order to assess relevant clinical aspects of implanted LAA occlusion devices being outlined within a pictorial essay. The following clinical aspects of implanted LAA occlusion devices were evaluated within the most appropriate cCTA multi-planar reconstruction: (1) topography to neighboring structures, (2) peri-device leaks, (3) coverage of LAA lobes, (4) indirect signs of neo-endothelialization. These are illustrated within concise CT imaging examples emphasizing the potential value of the proposed cCTA imaging algorithm: Starting from anatomical cCTA planes and stepwise angulation planes perpendicular to the base of the LAA devices generates an optimal LAA Occluder View for post-implantation Evaluation (LOVE). Aligned true axial, sagittal and coronal LOVE planes offer a standardized and detailed evaluation of LAA occlusion devices after percutaneous implantation. This pictorial essay presents a standardized imaging proposal by cCTA using multi-planar reconstructions that enables systematical follow-up and comparison of patients after LAA occlusion device implantation. The online version of this article (doi:10.1186/s12880-016-0127-y) contains supplementary material, which is available to authorized users

  10. Relationship of CHA2DS2-VASc and CHADS2 score to left atrial remodeling detected by velocity vector imaging in patients with atrial fibrillation.

    Directory of Open Access Journals (Sweden)

    Yihui Li

    Full Text Available BACKGROUND: The CHADS2/CHA2DS2-VASc scores are used to predict thrombo-embolic/stroke in patients with nonvalvular atrial fibrillation (AF. Nevertheless, limited data are available regarding the association between these risk stratification for stroke and left atrial (LA remodeling status of AF patients. The purpose of this study was to explore the association between these scores and LA remodeling status assessed quantificationally by echocardiography in AF patients. METHODS: One hundred AF patients were divided into 3 groups based on the CHA2DS2-VASc/CHADS2 score: the score of 0 (low stroke risk, the score of 1 (moderate stroke risk and the score of ≥2 (high stroke risk. All patients were performed through conventional and velocity vector imaging echocardiography. Echocardiographic parameters: maximum LA volume index (LAVImax, LA total emptying fraction (LAEFt and LA mean strain were obtained to assess quantificationally LA remodeling status. RESULTS: On categorizing with CHA2DS2-VASc, the score of 1 group showed augment in LAVImax and attenuation in LA mean strain derived from VVI, compared with the score of 0 group (LAVImax: 40.27±21.91 vs. 26.79±7.87, p=0.002; LA mean strain: 15.18±6.36 vs. 22±8.54, p=0.001. On categorizing with the CHADS2 score, similar trends were seen between the score of ≥2 and 1 groups (LAVImax: 43.72±13.77 vs. 31.41±9.50, p<0.001; LA mean strain: 11.01±5.31 vs. 18.63±7.00, p<0.001. With multivariate logistic regression, LAVImax (odds ratio: 0.92 , 95% C=I: 0.85 to 0.98, p= 0.01 and LA mean strain reflecting LA remodeling (odds ratio: 1.10, 95% CI: 1.02 to 1.19, p=0.01 were strongly predictive of the CHA2DS2-VASc score of 0. CONCLUSIONS: The superiority of the CHADS2 score may lay in identifying LA remodeling of AF patients with high stroke risk. Whereas, the CHA2DS2-VASc score was better than the CHADS2 score at identifying LA remodeling of AF patients presenting low stroke risk.

  11. CT based 3D printing is superior to transesophageal echocardiography for pre-procedure planning in left atrial appendage device closure.

    Science.gov (United States)

    Obasare, Edinrin; Mainigi, Sumeet K; Morris, D Lynn; Slipczuk, Leandro; Goykhman, Igor; Friend, Evan; Ziccardi, Mary Rodriguez; Pressman, Gregg S

    2018-05-01

    Accurate assessment of the left atrial appendage (LAA) is important for pre-procedure planning when utilizing device closure for stroke reduction. Sizing is traditionally done with transesophageal echocardiography (TEE) but this is not always precise. Three-dimensional (3D) printing of the LAA may be more accurate. 24 patients underwent Watchman device (WD) implantation (71 ± 11 years, 42% female). All had complete 2-dimensional TEE. Fourteen also had cardiac computed tomography (CCT) with 3D printing to produce a latex model of the LAA for pre-procedure planning. Device implantation was unsuccessful in 2 cases (one with and one without a 3D model). The model correlated perfectly with implanted device size (R 2  = 1; p < 0.001), while TEE-predicted size showed inferior correlation (R 2  = 0.34; 95% CI 0.23-0.98, p = 0.03). Fisher's exact test showed the model better predicted final WD size than TEE (100 vs. 60%, p = 0.02). Use of the model was associated with reduced procedure time (70 ± 20 vs. 107 ± 53 min, p = 0.03), anesthesia time (134 ± 31 vs. 182 ± 61 min, p = 0.03), and fluoroscopy time (11 ± 4 vs. 20 ± 13 min, p = 0.02). Absence of peri-device leak was also more likely when the model was used (92 vs. 56%, p = 0.04). There were trends towards reduced trans-septal puncture to catheter removal time (50 ± 20 vs. 73 ± 36 min, p = 0.07), number of device deployments (1.3 ± 0.5 vs. 2.0 ± 1.2, p = 0.08), and number of devices used (1.3 ± 0.5 vs. 1.9 ± 0.9, p = 0.07). Patient specific models of the LAA improve precision in closure device sizing. Use of the printed model allowed rapid and intuitive location of the best landing zone for the device.

  12. Associations of electrocardiographic P-wave characteristics with left atrial function, and diffuse left ventricular fibrosis defined by cardiac magnetic resonance: The PRIMERI Study.

    Science.gov (United States)

    Tiffany Win, Theingi; Ambale Venkatesh, Bharath; Volpe, Gustavo J; Mewton, Nathan; Rizzi, Patricia; Sharma, Ravi K; Strauss, David G; Lima, Joao A; Tereshchenko, Larisa G

    2015-01-01

    Abnormal P-terminal force in lead V1 (PTFV1) is associated with an increased risk of heart failure, stroke, atrial fibrillation, and death. Our goal was to explore associations of left ventricular (LV) diffuse fibrosis with left atrial (LA) function and electrocardiographic (ECG) measures of LA electrical activity. Patients without atrial fibrillation (n = 91; mean age 59.5 years; 61.5% men; 65.9% white) with structural heart disease (spatial QRS-T angle ≥105° and/or Selvester QRS score ≥5 on ECG) but LV ejection fraction >35% underwent clinical evaluation, cardiac magnetic resonance, and resting ECG. LA function indices were obtained by multimodality tissue tracking using 2- and 4-chamber long-axis images. T1 mapping and late gadolinium enhancement were used to assess diffuse LV fibrosis and presence of scar. P-prime in V1 amplitude (PPaV1) and duration (PPdV1), averaged P-wave-duration, PR interval, and P-wave axis were automatically measured using 12 SLTM algorithm. PTFV1 was calculated as a product of PPaV1 and PPdV1. In linear regression after adjustment for demographic characteristics, body mass index, maximum LA volume index, presence of scar, and LV mass index, each decile increase in LV interstitial fibrosis was associated with 0.76 mV*ms increase in negative abnormal PTFV1 (95% confidence interval [CI] -1.42 to -0.09; P = .025), 15.3 ms prolongation of PPdV1 (95% CI 6.9 to 23.8; P = .001) and 5.4 ms prolongation of averaged P-duration (95% CI 0.9-10.0; P = .020). LV fibrosis did not affect LA function. PPaV1 and PTFV1 were associated with an increase in LA volumes and decrease in LA emptying fraction and LA reservoir function. LV interstitial fibrosis is associated with abnormal PTFV1, prolonged PPdV1, and P-duration, but does not affect LA function. Copyright © 2015 Heart Rhythm Society. All rights reserved.

  13. Oclusão do apêndice atrial esquerdo com o Amplatzer Cardiac Plug em pacientes com fibrilação atrial Left atrial appendage closure with the Amplatzer Cardiac Plug in patients with atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Ênio Eduardo Guérios

    2012-06-01

    Full Text Available FUNDAMENTO: A oclusão percutânea do apêndice atrial esquerdo (OAAE surgiu como alternativa à anticoagulação oral (AO para prevenção do acidente vascular cerebral (AVC em pacientes com fibrilação atrial não-valvular (FANV. OBJETIVO: Relatar os resultados imediatos e o seguimento clínico de pacientes submetidos a OAAE com o Amplatzer Cardiac Plug (ACP em um único centro de referência. MÉTODOS: Oitenta e seis pacientes consecutivos com FANV, contra-indicação à AO e escore CHADS2= 2,6±1,2 foram submetidos a OAAE com implante de ACP. Realizou-se seguimento clínico e ecocardiográfico no mínimo 4 meses após o implante. RESULTADOS: Todos os implantes foram guiados apenas por angiografia. O sucesso do procedimento foi de 99% (1 insucesso por tamponamento cardíaco e consequente suspensão da OAAE. Houve 4 complicações maiores (o tamponamento já referido, 2 AVCs transitórios e uma embolização com retirada percutânea da prótese e duas menores (um derrame pericárdico sem tamponamento e uma pequena comunicação interatrial evidenciada no seguimento. Houve 1 óbito hospitalar após 6 dias, não relacionado à intervenção. Todos os outros pacientes receberam alta sem AO. Após seguimento de 25,9 pacientes-ano (69 pacientes não houve AVCs nem embolizações tardias de próteses. O AAE estava completamente ocluído em 97% dos casos. Seis pacientes apresentaram evidência de trombo sobre a prótese, que desapareceram após reinstituição de AO por 3 meses. CONCLUSÃO: OAAE se associa a um alto índice de sucesso, um índice aceitável de complicações e resultados promissores a médio prazo, podendo ser considerada uma alternativa válida à OA na prevenção do AVC em pacientes com FANV.BACKGROUND: Percutaneous left atrial appendage closure (LAAC has emerged as an alternative to oral anticoagulation (OA for prevention of thromboembolic stroke in patients with non-valvular atrial fibrillation (NVAF. OBJECTIVE: To describe the

  14. Measurement of Thrombus Flux Using Transesophageal Echocardiography

    Science.gov (United States)

    Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya, Hiroyuki

    2006-05-01

    Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the FSET to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed.

  15. Measurement of thrombus flux using transesophageal Echocardiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya Hiroyuki

    2006-01-01

    Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the fiber structure extraction technique (FSET) to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed. (author)

  16. Evaluation of radiocolloids as thrombus imaging agents. Effect of particle size on thrombus uptake

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, S.N.; Bardfeld, P.A.

    1985-01-01

    Thrombus uptake values of several /sup 99m/Tc labeled radiocolloids determined using an experimental rodent model of deep venous thrombosis were correlated with particle size distributions. The thrombus uptake values increased with increasing mean particle size. The /sup 99m/Tc-tin colloid had the highest thrombus uptake value of any of the colloids used in this study.

  17. Superior Venacava Thrombus-A Case Report

    Directory of Open Access Journals (Sweden)

    Bijay Sah

    2016-03-01

    Full Text Available Superior venacava (SVC thrombus is a condition requiring immediate diagnosis and treatment. SVC thrombus causes obstruction of blood flow through the SVC resulting in severe decrease in venous return from the head, neck and upper extremity to the heart. The presenting symptoms of SVC obstruction include headache, hoarseness of voice, dyspnea, and laryngeal edema, dizziness, swelling of face, neck, and upper extremity. We hereby present a case of SVC thrombus who presented to the casualty department of COMS-TH with features of SVC syndrome which was diagnosed and managed promptly.JCMS Nepal. 2016;12(1:33-5.

  18. Thrombus Formation at High Shear Rates.

    Science.gov (United States)

    Casa, Lauren D C; Ku, David N

    2017-06-21

    The final common pathway in myocardial infarction and ischemic stroke is occlusion of blood flow from a thrombus forming under high shear rates in arteries. A high-shear thrombus forms rapidly and is distinct from the slow formation of coagulation that occurs in stagnant blood. Thrombosis at high shear rates depends primarily on the long protein von Willebrand factor (vWF) and platelets, with hemodynamics playing an important role in each stage of thrombus formation, including vWF binding, platelet adhesion, platelet activation, and rapid thrombus growth. The prediction of high-shear thrombosis is a major area of biofluid mechanics in which point-of-care testing and computational modeling are promising future directions for clinically relevant research. Further research in this area will enable identification of patients at high risk for arterial thrombosis, improve prevention and treatment based on shear-dependent biological mechanisms, and improve blood-contacting device design to reduce thrombosis risk.

  19. Antibody-targeted thrombus imaging and thrombolysis

    International Nuclear Information System (INIS)

    Wu Guoxin; Ruan Changgeng

    1993-05-01

    In respect of thrombus imaging, the femoral arterial or venous thrombus model was prepared in dogs and imaged with single photon emission computerized tomography (SPECT). After 4 hours of injection of 131 I-SZ-51 the radioactivity ratio between thrombus and blood (T/B) was 18 : 1 and 8 : 1 for arterial and venous thrombus respectively. The result conformed with the T/B ratio of the removed thrombus and blood after 24 hours of injection of radiotracer. It indicates that the McAb SZ-51 has a great potential to bind with thrombus. In respect of thrombolysis, the Fab(fragment, antigen-binding) fragment of McAb SZ-51 was chemically conjugated of urokinase (UK) by the disulfide-linking reagent SPDP and 2-iminothiolane. The resulting conjugate was 3 to 5 times as potent as UK in vitro in human platelet-rich plasma assay. The increase of fibrinolytic potency was accompanied by a decrease of consumption of plasminogen and fibrinogen. It shows that the increase of potency is the result of selectivity increase

  20. Multi-Constituent Simulation of Thrombus Deposition.

    Science.gov (United States)

    Wu, Wei-Tao; Jamiolkowski, Megan A; Wagner, William R; Aubry, Nadine; Massoudi, Mehrdad; Antaki, James F

    2017-02-20

    In this paper, we present a spatio-temporal mathematical model for simulating the formation and growth of a thrombus. Blood is treated as a multi-constituent mixture comprised of a linear fluid phase and a thrombus (solid) phase. The transport and reactions of 10 chemical and biological species are incorporated using a system of coupled convection-reaction-diffusion (CRD) equations to represent three processes in thrombus formation: initiation, propagation and stabilization. Computational fluid dynamic (CFD) simulations using the libraries of OpenFOAM were performed for two illustrative benchmark problems: in vivo thrombus growth in an injured blood vessel and in vitro thrombus deposition in micro-channels (1.5 mm × 1.6 mm × 0.1 mm) with small crevices (125 μm × 75 μm and 125 μm × 137 μm). For both problems, the simulated thrombus deposition agreed very well with experimental observations, both spatially and temporally. Based on the success with these two benchmark problems, which have very different flow conditions and biological environments, we believe that the current model will provide useful insight into the genesis of thrombosis in blood-wetted devices, and provide a tool for the design of less thrombogenic devices.

  1. Multi-Constituent Simulation of Thrombus Deposition

    Science.gov (United States)

    Wu, Wei-Tao; Jamiolkowski, Megan A.; Wagner, William R.; Aubry, Nadine; Massoudi, Mehrdad; Antaki, James F.

    2017-02-01

    In this paper, we present a spatio-temporal mathematical model for simulating the formation and growth of a thrombus. Blood is treated as a multi-constituent mixture comprised of a linear fluid phase and a thrombus (solid) phase. The transport and reactions of 10 chemical and biological species are incorporated using a system of coupled convection-reaction-diffusion (CRD) equations to represent three processes in thrombus formation: initiation, propagation and stabilization. Computational fluid dynamic (CFD) simulations using the libraries of OpenFOAM were performed for two illustrative benchmark problems: in vivo thrombus growth in an injured blood vessel and in vitro thrombus deposition in micro-channels (1.5 mm × 1.6 mm × 0.1 mm) with small crevices (125 μm × 75 μm and 125 μm × 137 μm). For both problems, the simulated thrombus deposition agreed very well with experimental observations, both spatially and temporally. Based on the success with these two benchmark problems, which have very different flow conditions and biological environments, we believe that the current model will provide useful insight into the genesis of thrombosis in blood-wetted devices, and provide a tool for the design of less thrombogenic devices.

  2. Having a Ball with Fitness Balls

    Science.gov (United States)

    McNulty, Betty

    2011-01-01

    Fitness programs can be greatly enhanced with the addition of fitness balls. They are a fun, challenging, economical, and safe way to incorporate a cardiovascular, strength, and stretching program for all fitness levels in a physical education setting. The use of these balls has become more popular during the last decade, and their benefits and…

  3. The Goldenrod Ball Gall

    Science.gov (United States)

    Fischer, Richard B.

    1974-01-01

    The paper presents a generalized life history of the goldenrod ball gall, a ball-shaped swelling found almost exclusively on the Canada goldenrod, Solidago canadensis, and caused by a peacock fly know as Eurosta soldiaginis. (KM)

  4. The incredible shrinking ball

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Maurice

    2011-12-15

    In the oil and gas industry, the implementation of fracture systems using ball and seat technology helped make multistage fracturing possible. However, frac balls can obstruct later production flow by staying in the well. Baker Hughes Inc. developed a technology to solve this problem: IN-Tallic frac balls. The unique feature of these frac balls is that they are made of an electrolytic metallic nanostructured material which is light and strong and which melts away with salt water or brine through a decomposition process governed by electrochemical reactions controlled by nanoscale coatings. These balls need to be kept away from moisture in order to prevent degradation. This technology is more expensive than traditional frac balls but it prevents the need to mill out obstructions created by the balls. The IN-Tallic frac balls are a new technology which provides operators with peace of mind.

  5. Ball Screw Actuator Including a Compliant Ball Screw Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2017-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  6. Usefulness of left ventricular speckle tracking echocardiography and novel measures of left atrial structure and function in diagnosing paroxysmal atrial fibrillation in ischemic stroke and transient ischemic attack patients.

    Science.gov (United States)

    Skaarup, Kristoffer Grundtvig; Christensen, Hanne; Høst, Nis; Mahmoud, Masti Mahdy; Ovesen, Christian; Olsen, Flemming Javier; Jensen, Jan Skov; Biering-Sørensen, Tor

    2017-12-01

    Asymptomatic paroxysmal atrial fibrillation (PAF) is often assumed to be the cause of cryptogenic ischemic strokes (IS) and transient ischemic attacks (TIA). We examined the usefulness of measures obtained by 2D speckle tracking echocardiography and novel left atrial measurements, in the diagnosis of PAF in patients with IS and TIA. We retrospectively included 205 patients who after acute IS or TIA underwent an echocardiogram in sinus rhythm. Patients were designated as PAF-patients if they had one or more reported incidents of AF before or after their echocardiographic examination. None of the conventional echocardiographic parameters were significantly associated with PAF. Of the speckle tracking measurements, only early diastolic strain rate (0.7±0.2 s -1 vs. 0.8±0.3 s -1 , p = 0.048) and global longitudinal displacement (GLD) (3.15 ± 1.40 mm vs. 3.87 ± 1.56 mm, p = 0.007) proved significantly different. Of the left atrial parameters both minimal and maximal left atrium volume divided by left ventricular length (min LAV/LVL and max LAV/LVL, respectively) were significantly impaired (min LAV/LVL: 3.7 ± 2.1 cm 2 vs. 2.8 ± 1.11 cm 2 , p = 0.012; max LAV/LVL: 6.6 ± 3.1 cm 2 vs. 5.6 ± 1.7 cm 2 , p = 0.012). GLD, min max LAV/LVL proved significant after adjustment for age, gender, CHA 2 DS 2 -VASc and NIHSS. By combining information regarding age, GLD, min and max LAV/LVL the diagnostic accuracy of PAF improved, resulting in a significantly increased area under the curve (p = 0.037). In patients with IS and TIA GLD, min and max LAV/LVL were independently associated with the presence of PAF.

  7. Long-term fate of left atrial thrombi and incidence of cerebral embolism under continuous anticoagulation therapy; MR-tomographische Evaluation der Inzidenz zerebraler Embolien bei Patienten mit Vorhofflimmern und linksatrialen Thromben

    Energy Technology Data Exchange (ETDEWEB)

    Strach, K.; Meyer, C.; Hackenbroch, M.; Schild, H.; Sommer, T. [Radiologische Universitaetsklinik Bonn (Germany); Tiemann, K. [Medizinische Universitaetsklinik und Poliklinik II, Bonn (Germany); Haase, J. [Klinik Rotes Kreuz, Frankfurt/Main (Germany); Pizulli, L. [Petruskrankenhaus, Bonn (Germany); Omran, H. [St. Marien-Hospital, Bonn (Germany)

    2005-12-15

    Purpose: Patients (pts.) with atrial fibrillation (AF) and atrial thrombi are known to have an increased risk for cerebral embolism. However, little is known about the clinical course of atrial thrombi and the incidence of cerebral embolism in those patients during anticoagulation therapy. The high sensitivity of MR imaging (MRI) including diffusion-weighted imaging (DWI) suggests that this technique could provide an improved estimate of cerebral embolism associated with the presence of left atrial thrombi. The aims of this prospective study were to evaluate (1) the prevalence of clinically silent and apparent cerebral embolism in pts. with newly diagnosed AF and atrial thrombi using MRI/DWI, (2) the long-term fate of atrial thrombi under continued anticoagulation therapy and (3) the incidence of cerebral embolism during a follow-up period of 12 months with continuous anticoagulation therapy. Materials and methods: The study group consisted of 32 pts. with (1) newly diagnosed AF and evidence of left atrial (LA) thrombi detected by TEE and (2) a new start of anticoagulation therapy [International Normalized Ratio (INR) 2.0-3.0]. 19 pts. with (1) newly diagnosed AF and no evidence of atrial thrombi and (2) an equivalent anticoagulation regimen served as the control group. In both groups (a) MRI/DWI studies of the brain (weeks 0, 4, 8, 12, 20, 28, 36, 44, and 52), (b) transesophageal echocardiographic studies (TEE) for assessment of LA-Thrombi (weeks 0 and 52) and (c) clinical neurological assessments (weeks 0, 20 and 52) were performed. Results: In the study group (AF and LA-Thrombi) 11 out of 32 pts. (34%) displayed signs of acute (n=8) or chronic (n=3) cerebral embolism in the initial MRI studies. In 4 out of 32 pts.(13%), MRI/DWI depicted new or additional cerebral emboli (n=12) during the follow-up period despite continuous anticoagulation therapy. 2 (n=2/4; 50%) of these patients had clinically apparent neurological deficits. In the control group 1 out of 19 pts

  8. The spinning ball spiral

    International Nuclear Information System (INIS)

    Dupeux, Guillaume; Le Goff, Anne; Quere, David; Clanet, Christophe

    2010-01-01

    We discuss the trajectory of a fast revolving solid ball moving in a fluid of comparable density. As the ball slows down owing to drag, its trajectory follows an exponential spiral as long as the rotation speed remains constant: at the characteristic distance L where the ball speed is significantly affected by the drag, the bending of the trajectory increases, surprisingly. Later, the rotation speed decreases, which makes the ball follow a second kind of spiral, also described in the paper. Finally, the use of these highly curved trajectories is shown to be relevant to sports.

  9. Presence of left atrial diverticula, accessory appendages, and normal variant pulmonary venous anatomy diagnosed using MDCT and adverse outcomes following radiofrequency catheter ablation therapy in patients with drug-refractory atrial fibrillation: An exploratory study

    International Nuclear Information System (INIS)

    Patel, S.N.; French, A.; Mathias, H.; Lyen, S.; Hamilton, M.C.K.; Manghat, N.E.

    2013-01-01

    Aim: To determine the frequency of normal variation left atrial anatomy (NVLAA) (diverticula, accessory appendages) and normal variation pulmonary venous anatomy (NVPVA) in patients with atrial fibrillation (AF), and to determine whether the presence of these entities is associated with an increased recurrence of atrial arrhythmias following radiofrequency catheter ablation (RFCA). Materials and methods: All cardiac MDCT images performed prior to RFCA between November 2009 and May 2011 in patients with drug-refractory AF were retrospectively evaluated. The presence, type, and location of NVLAA and NVPVA, and outcome of RFCA were recorded. Success was defined as restoration of sinus rhythm. Results: Forty-six consecutive patients with a mean age of 59.8 (±9.7) years (76.1% male) underwent cardiac MDCT for anatomical planning prior to RFCA procedures. Fourteen (30.4%) patients had NVLAA, 35% of patients had NVPVA. Thirty (65%) patients had successful RFCA: 57% of these had a NVLAA, 67% had NVPVA. Sixteen (35%) patients had unsuccessful RFCA: 63% of these had a NVLAA, 56% had NVPVA. There was no significant association between the presence of NVLAA (p = 0.699), NVPVA (p = 0.197), or “NVLAA in the presence of normal pulmonary venous anatomy” (p = 0.589) and the outcome of RFCA. Conclusion: The presence of NVLAA and NVPVA appears unrelated to adverse outcome in patients undergoing RFCA for the treatment of drug-refractory AF

  10. Long-term follow-up of patients with paroxysmal atrial fibrillation and severe left atrial scarring: comparison between pulmonary vein antrum isolation only or pulmonary vein isolation combined with either scar homogenization or trigger ablation.

    Science.gov (United States)

    Mohanty, Sanghamitra; Mohanty, Prasant; Di Biase, Luigi; Trivedi, Chintan; Morris, Eli Hamilton; Gianni, Carola; Santangeli, Pasquale; Bai, Rong; Sanchez, Javier E; Hranitzky, Patrick; Gallinghouse, G Joseph; Al-Ahmad, Amin; Horton, Rodney P; Hongo, Richard; Beheiry, Salwa; Elayi, Claude S; Lakkireddy, Dhanunjaya; Madhu Reddy, Yaruva; Viles Gonzalez, Juan F; Burkhardt, J David; Natale, Andrea

    2017-11-01

    Left atrial (LA) scarring, a consequence of cardiac fibrosis is a powerful predictor of procedure-outcome in atrial fibrillation (AF) patients undergoing catheter ablation. We sought to compare the long-term outcome in patients with paroxysmal AF (PAF) and severe LA scarring identified by 3D mapping, undergoing pulmonary vein isolation (PVAI) only or PVAI and the entire scar areas (scar homogenization) or PVAI+ ablation of the non-PV triggers. Totally, 177 consecutive patients with PAF and severe LA scarring were included. Patients underwent PVAI only (n = 45, Group 1), PVAI+ scar homogenization (n = 66, Group 2) or PVAI+ ablation of non-PV triggers (n = 66, Group 3) based on operator's choice. Baseline characteristics were similar across the groups. After first procedure, all patients were followed-up for a minimum of 2 years. The success rate at the end of the follow-up was 18% (8 pts), 21% (14 pts), and 61% (40 pts) in Groups 1, 2, and 3, respectively. Cumulative probability of AF-free survival was significantly higher in Group 3 (overall log-rank P homogenization. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  11. Compact Q-balls

    Energy Technology Data Exchange (ETDEWEB)

    Bazeia, D., E-mail: bazeia@fisica.ufpb.br [Departamento de Física, Universidade Federal da Paraíba, 58051-970 João Pessoa, PB (Brazil); Losano, L.; Marques, M.A. [Departamento de Física, Universidade Federal da Paraíba, 58051-970 João Pessoa, PB (Brazil); Menezes, R. [Departamento de Ciências Exatas, Universidade Federal da Paraíba, 58297-000 Rio Tinto, PB (Brazil); Departamento de Física, Universidade Federal de Campina Grande, 58109-970 Campina Grande, PB (Brazil); Rocha, R. da [Centro de Matemática, Computação e Cognição, Universidade Federal do ABC, 09210-580 Santo André (Brazil)

    2016-07-10

    In this work we deal with non-topological solutions of the Q-ball type in two space–time dimensions, in models described by a single complex scalar field that engenders global symmetry. The main novelty is the presence of stable Q-balls solutions that live in a compact interval of the real line and appear from a family of models controlled by two distinct parameters. We find analytical solutions and study their charge and energy, and show how to control the parameters to make the Q-balls classically and quantum mechanically stable.

  12. Value of Combining Left Atrial Diameter and Amino-terminal Pro-brain Natriuretic Peptide to the CHA2DS2-VASc Score for Predicting Stroke and Death in Patients with Sick Sinus Syndrome after Pacemaker Implantation.

    Science.gov (United States)

    Mo, Bin-Feng; Lu, Qiu-Fen; Lu, Shang-Biao; Xie, Yu-Quan; Feng, Xiang-Fei; Li, Yi-Gang

    2017-08-20

    The CHA2DS2-VASc score is used clinically for stroke risk stratification in patients with atrial fibrillation (AF). We sought to investigate whether the CHA2DS2-VASc score predicts stroke and death in Chinese patients with sick sinus syndrome (SSS) after pacemaker implantation and to evaluate whether the predictive power of the CHA2DS2-VASc score could be improved by combining it with left atrial diameter (LAD) and amino-terminal pro-brain natriuretic peptide (NT-proBNP). A total of 481 consecutive patients with SSS who underwent pacemaker implantation from January 2004 to December 2014 in our department were included. The CHA2DS2-VASc scores were retrospectively calculated according to the hospital medical records before pacemaker implantation. The outcome data (stroke and death) were collected by pacemaker follow-up visits and telephonic follow-up until December 31, 2015. During 2151 person-years of follow-up, 46 patients (9.6%) suffered stroke and 52 (10.8%) died. The CHA2DS2-VASc score showed a significant association with the development of stroke (hazard ratio [HR] 1.45, 95% confidence interval [CI] 1.20-1.75, Ppacemaker implantation. The addition of LAD and NT-proBNP to the CHA2DS2-VASc score improved its predictive power for stroke and death, respectively, in this patient cohort. Future prospective studies are warranted to validate the benefit of adding LAD and NT-proBNP to the CHA2DS2-VASc score for predicting stroke and death risk in non-AF populations.

  13. Simplified single plane echocardiography is comparable to conventional biplane two-dimensional echocardiography in the evaluation of left atrial volume: a study validated by three-dimensional echocardiography in 143 individuals.

    Science.gov (United States)

    Vieira-Filho, Normando G; Mancuso, Frederico J N; Oliveira, Wercules A A; Gil, Manuel A; Fischer, Cláudio H; Moises, Valdir A; Campos, Orlando

    2014-03-01

    The left atrial volume index (LAVI) is a biomarker of diastolic dysfunction and a predictor of cardiovascular events. Three-dimensional echocardiography (3DE) is highly accurate for LAVI measurements but is not widely available. Furthermore, biplane two-dimensional echocardiography (B2DE) may occasionally not be feasible due to a suboptimal two-chamber apical view. Simplified single plane two-dimensional echocardiography (S2DE) could overcome these limitations. We aimed to compare the reliability of S2DE with other validated echocardiographic methods in the measurement of the LAVI. We examined 143 individuals (54 ± 13 years old; 112 with heart disease and 31 healthy volunteers; all with sinus rhythm, with a wide range of LAVI). The results for all the individuals were compared with B2DE-derived LAVIs and validated using 3DE. The LAVIs, as determined using S2DE (32.7 ± 13.1 mL/m(2)), B2DE (31.9 ± 12.7 mL/m(2)), and 3DE (33.1 ± 13.4 mL/m(2)), were not significantly different from each other (P = 0.85). The S2DE-derived LAVIs correlated significantly with those obtained using both B2DE (r = 0.98; P < 0.001) and 3DE (r = 0.93; P < 0.001). The mean difference between the S2DE and B2DE measurements was <1.0 mL/m(2). Using the American Society of Echocardiography criteria for grading LAVI enlargement (normal, mild, moderate, severe), we observed an excellent agreement between the S2DE- and B2DE-derived classifications (κ = 0.89; P < 0.001). S2DE is a simple, rapid, and reliable method for LAVI measurement that may expand the use of this important biomarker in routine echocardiographic practice. © 2013, Wiley Periodicals, Inc.

  14. Cirurgia cardíaca de emergência para ressecção de mixoma atrial esquerdo Cardiac surgery of emergency for resection of left atrial myxoma

    Directory of Open Access Journals (Sweden)

    Antônio Augusto Ramalho Motta

    2008-06-01

    Full Text Available É descrito caso de paciente do sexo feminino que apresentava manifestações pulmonares e sistêmicas inespecíficas há vários meses, as quais resultaram em várias internações hospitalares com a hipótese diagnóstica de fibrose pulmonar. Estudo ecocardiográfico evidenciou a presença de grande mixoma pediculado no átrio esquerdo, que prolapsava, através da valva mitral, para o ventrículo esquerdo. Em condições clínicas bastante desfavoráveis, a paciente foi encaminhada ao nosso Serviço para tratamento cirúrgico, evoluindo durante o preparo pré-operatório com edema agudo pulmonar e instabilidade hemodinâmica, sendo submetida a cirurgia de emergência, com sucesso, para ressecção da tumoração. A paciente encontra-se assintomática.We report case of a female patient who during months presented pulmonary manifestation associated with nonspecific systemic symptoms resulting in several hospitalizations with the diagnostic hypothesis of pulmonary fibrosis. The echocardiographic study showed a great pedunculated left atrial myxoma prolapsing through the mitral valve for the left ventricle. In quite unfavorable clinical conditions the patient was sent to our Service for surgical treatment, evolving during the preparation for surgery with acute pulmonary edema and hemodinamic instability being submitted to a successfully surgery of emergency for resection of the tumor. The patient is asymptomatic.

  15. A Therapeutic Challenge: Management of Atrial Thrombus

    Directory of Open Access Journals (Sweden)

    Serkan Burc Deser

    2016-09-01

    Full Text Available Introduction: Primary cause of atrial thrombi include atrial fibrillation, foreign bodies inside the atrium such as catheters and pacemaker leads, emboli of deep venous thrombus and primary or metastatic tumors of the heart. We review the clinical features, epidemiology, diagnosis and treatment of nine intriguing cases with atrial thrombus. Methods: This is a retrospective study of nine patients (seven female (78%, two male (33% who were diagnosed with atrial thrombi (average age of 50 ± 12 years and were treated at the Ondokuz Mayis University, Department of Cardiovascular Surgery from February 2014 to January 2015. Among them, six patients had atrial fibrillation (one male, five female, seven patients were suffering from dispne and orthopnoea, five patients were suffering from leg swelling, seven patients had a history of hypertension and three patients had a history of mitral valve replacement surgery. Results: All patients underwent surgery except one. Four patients recovered uneventfully and discharged with oral anticoagulation (warfarin therapy (adjusted to maintain an international normalized ratio of INR between two and three times. Five of nine patients (55% died after surgery. Conclusion: The response to the thrombolytic therapy is poor, mostly ineffective and unsafe so it is often recommended as a bridge to surgery. In patients diagnosed with mechanical mitral valve thrombosis, medical therapy has the possibility of end organ emboli and also fail to resolve the organised thrombus on the stuck valve. On the other hand surgery does not always give satisfactory results. J Clin Exp Invest 2016; 7(4: 278-282

  16. The bowling balls

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    10 November 1972: CERN’s Bent Stumpe places an order for 12 bowling balls for a total cost of 95 US dollars. Although not evident at first sight, he is buying the heart of some of the first tracking devices to be used in the SPS control room. Today, Bent Stumpe’s device would be called a desktop mouse…   The first order for 4 bowling balls later changed to 12 balls. The bowling balls became the heart of Bent Stumpe's mouse. Almost 40 years ago, the web, Wikipedia and Google did not exist and it was much more difficult to know whether other people in other parts of the world or even in the same laboratory were facing the same problems or developing the same tools. At that time, Bent Stumpe was an electronics engineer, newly recruited to work on developments for the SPS Central Control room. One of the things his supervisor asked him to build as soon as possible was a device to control a pointer on a screen, also called a tracker ball. The heart of the device was the...

  17. Ultrasound Detection of Superior Vena Cava Thrombus

    Directory of Open Access Journals (Sweden)

    Aaron Birch

    2014-09-01

    Full Text Available Superior vena cava (SVC syndrome is most commonly the insidious result of decreased vascular flow through the SVC due to malignancy, spontaneous thrombus, infections, and iatrogenic etiologies. Clinical suspicion usually leads to computed tomography to confirm the diagnosis. However, when a patient in respiratory distress requires emergent airway management, travel outside the emergency department is not ideal. With the growing implementation of point-of-care ultrasound (POCUS, clinicians may make critical diagnoses rapidly and safely. We present a case of SVC syndrome due to extensive thrombosis of the deep venous system cephalad to the SVC diagnosed by POCUS. [West J Emerg Med. 2014;15(6:715-718

  18. Segmentation, Reconstruction, and Analysis of Blood Thrombus Formation in 3D 2-Photon Microscopy Images

    Directory of Open Access Journals (Sweden)

    Xu Zhiliang

    2010-01-01

    Full Text Available We study the problem of segmenting, reconstructing, and analyzing the structure growth of thrombi (clots in blood vessels in vivo based on 2-photon microscopic image data. First, we develop an algorithm for segmenting clots in 3D microscopic images based on density-based clustering and methods for dealing with imaging artifacts. Next, we apply the union-of-balls (or alpha-shape algorithm to reconstruct the boundary of clots in 3D. Finally, we perform experimental studies and analysis on the reconstructed clots and obtain quantitative data of thrombus growth and structures. We conduct experiments on laser-induced injuries in vessels of two types of mice (the wild type and the type with low levels of coagulation factor VII and analyze and compare the developing clot structures based on their reconstructed clots from image data. The results we obtain are of biomedical significance. Our quantitative analysis of the clot composition leads to better understanding of the thrombus development, and is valuable to the modeling and verification of computational simulation of thrombogenesis.

  19. Detection of extracellular genomic DNA scaffold in human thrombus

    DEFF Research Database (Denmark)

    Oklu, Rahmi; Albadawi, Hassan; Watkins, Michael T

    2012-01-01

    into thrombus remodeling. MATERIALS AND METHODS: Ten human thrombus samples were collected during cases of thrombectomy and open surgical repair of abdominal aortic aneurysms (five samples 1 y old). Additionally, an acute murine hindlimb ischemia model was created to evaluate...... thrombus samples in mice. Human sections were immunostained for the H2A/H2B/DNA complex, myeloperoxidase, fibrinogen, and von Willebrand factor. Mouse sections were immunostained with the H2A antibody. All samples were further evaluated after hematoxylin and eosin and Masson trichrome staining. RESULTS......: An extensive network of extracellular histone/DNA complex was demonstrated in the matrix of human ex vivo thrombus. This network is present throughout the highly cellular acute thrombus. However, in chronic thrombi, detection of the histone/DNA network was predominantly in regions of low collagen content...

  20. Covered stent to exclude intravascular thrombus.

    Science.gov (United States)

    Liistro, Francesco; Stankovic, Goran; Di Mario, Carlo; Montorfano, Matteo; Briguori, Carlo; Colombo, Antonio

    2002-04-01

    To describe the utility of stent-graft implantation to avoid distal embolization from a large thrombus-containing lesion. A 67-year-old man was evaluated for recent onset of disabling left leg claudication. Angiography disclosed a mobile lobular mass occluding the left common iliac artery; irregular staining suggested an atherothrombotic lesion. Through a percutaneous ipsilateral access and an 8-F sheath, a balloon-expandable Jostent peripheral stent-graft was positioned with the distal edge immediately proximal to the internal iliac artery ostium. A prominent "waist" at the center of the balloon confirmed entrapment of the thrombotic mass. Completion angiography showed an optimal result with no residual stenosis or evidence of distal embolization. At 6-month follow-up, the patient was asymptomatic with angiographically documented luminal patency and no evidence of in-stent stenosis. Stent-graft implantation appears a viable treatment alternative for thrombus-containing lesions, particularly when the thrombotic material is localized or is in a large vessel.

  1. Laboratory demonstration of ball lightning

    International Nuclear Information System (INIS)

    Egorov, Anton I; Stepanov, Sergei I; Shabanov, Gennadii D

    2004-01-01

    A common laboratory facility for creating glowing flying plasmoids akin to a natural ball lightning, allowing a number of experiments to be performed to investigate the main properties of ball lightning, is described. (methodological notes)

  2. Categorization of aortic aneurysm thrombus morphology by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Motte, Louise de la, E-mail: louise.de.la.motte@rh.regionh.dk [Department of Vascular Surgery, Rigshospitalet and University of Copenhagen (Denmark); Pedersen, Mads Møller, E-mail: phd@medit.dk [Department of Radiology, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark); Thomsen, Carsten, E-mail: carsten.thomsen@rh.regionh.dk [Department of Radiology, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark); Vogt, Katja, E-mail: Vogt@dadlnet.dk [Department of Vascular Surgery, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark); Schroeder, Torben V., E-mail: Torben.Veith.schroeder@rh.regionh.dk [Department of Vascular Surgery, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark); Lonn, Lars, E-mail: lonn.lars@gmail.com [Department of Vascular Surgery and Department of Radiology, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)

    2013-10-01

    Background: Magnetic resonance imaging (MRI) has been proposed for qualitative categorization of intraluminal thrombus morphology. We aimed to correlate the qualitative MRI categorization previously described to quantitative measurements of signal intensity and to compare morphological characteristics of intraluminal thrombus specimens to the appearance on magnetic resonance imaging. Methods: Thirty-four patients undergoing open surgery for abdominal aortic aneurysm had a preoperative MRI obtained with a 1.5 T magnet. Qualitative categorization was performed (blinded and in consensus) and correlated to intraluminal thrombus to muscle signal-intensity ratios. Morphology of intraluminal thrombus specimens collected during surgery were compared to the magnetic resonance imaging categories and specimen weight was correlated to thrombus volume measured on preoperative computer tomography angiography. Results: Blinded MRI categorization resulted in agreement in 22 out of 34 intraluminal thrombi (Kappa value 0.3, p = 0.006). Medians (p = 0.004) and distribution (p = 0.002) of signal-intensity ratios varied significantly across the three MRI categories obtained by consensus. Heterogeneous and homogenous specimen appearance corresponded to similar appearances on MRI in 78% and 55% respectively, resulting in an overall Kappa = 0.4 (p = 0.04). Intraluminal thrombus volume and weight correlated well (r{sub s} 0.831, p < 0.001) with a mean difference of 60 g (95% CI 38–80 g), without proportional bias. Conclusion: Qualitative evaluation of intraluminal thrombus morphology based on MRI can be quantified by measuring signal-intensity ratios. Concurrently a fair agreement to blinded qualitative evaluation of thrombus specimens can be obtained. However, the evaluation is impaired by loss of a large proportion of thrombus during sampling.

  3. Categorization of aortic aneurysm thrombus morphology by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Motte, Louise de la; Pedersen, Mads Møller; Thomsen, Carsten; Vogt, Katja; Schroeder, Torben V.; Lonn, Lars

    2013-01-01

    Background: Magnetic resonance imaging (MRI) has been proposed for qualitative categorization of intraluminal thrombus morphology. We aimed to correlate the qualitative MRI categorization previously described to quantitative measurements of signal intensity and to compare morphological characteristics of intraluminal thrombus specimens to the appearance on magnetic resonance imaging. Methods: Thirty-four patients undergoing open surgery for abdominal aortic aneurysm had a preoperative MRI obtained with a 1.5 T magnet. Qualitative categorization was performed (blinded and in consensus) and correlated to intraluminal thrombus to muscle signal-intensity ratios. Morphology of intraluminal thrombus specimens collected during surgery were compared to the magnetic resonance imaging categories and specimen weight was correlated to thrombus volume measured on preoperative computer tomography angiography. Results: Blinded MRI categorization resulted in agreement in 22 out of 34 intraluminal thrombi (Kappa value 0.3, p = 0.006). Medians (p = 0.004) and distribution (p = 0.002) of signal-intensity ratios varied significantly across the three MRI categories obtained by consensus. Heterogeneous and homogenous specimen appearance corresponded to similar appearances on MRI in 78% and 55% respectively, resulting in an overall Kappa = 0.4 (p = 0.04). Intraluminal thrombus volume and weight correlated well (r s 0.831, p < 0.001) with a mean difference of 60 g (95% CI 38–80 g), without proportional bias. Conclusion: Qualitative evaluation of intraluminal thrombus morphology based on MRI can be quantified by measuring signal-intensity ratios. Concurrently a fair agreement to blinded qualitative evaluation of thrombus specimens can be obtained. However, the evaluation is impaired by loss of a large proportion of thrombus during sampling

  4. Deep venous thrombus characterization: ultrasonography, elastography and scattering operator

    OpenAIRE

    Thibaud Berthomier; Ali Mansour; Luc Bressollette; Frédéric Le Roy; Dominique Mottier

    2017-01-01

    A thrombus or a blood clot is the result of blood coagulation which is a natural process to prevent bleeding. An inappropriate formation of a thrombus in a deep vein is known as Deep Venous Thrombosis (DVT). The main complication of a DVT is a Pulmonary Embolism (PE) which occurs when a thrombus breaks loose and travels to the lungs. DVT, PE, or both are also known as Venous thromboembolism (VTE). It affects an estimated 300,000–600,000 Individuals just in the United States per year and can c...

  5. Frictional performance of ball screw

    International Nuclear Information System (INIS)

    Nakashima, Katuhiro; Takafuji, Kazuki

    1985-01-01

    As feed screws, ball screws have become to be adopted in place of trapezoidal threads. The structure of ball screws is complex, but those are the indispensable component of NC machine tools and machining centers, and are frequently used for industrial robots. As the problems in the operation of ball screws, there are damage, life and the performance related to friction. As to the damage and life, though there is the problem of the load distribution on balls, the results of the research on rolling bearings are applied. The friction of ball screws consists of the friction of balls and a spiral groove, the friction of a ball and a ball, the friction in a ball-circulating mechanism and the viscous friction of lubricating oil. It was decided to synthetically examine the frictional performance of ball screws, such as driving torque, the variation of driving torque, efficiency, the formation of oil film and so on, under the working condition of wide range, using the screws with different accuracy and the nuts of various circuit number. The experimental setup and the processing of the experimental data, the driving performance of ball screws and so on are reported. (Kako, I.)

  6. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  7. Categorization of aortic aneurysm thrombus morphology by magnetic resonance imaging

    DEFF Research Database (Denmark)

    de la Motte, Louise; Pedersen, Mads Møller; Thomsen, Carsten

    2013-01-01

    Magnetic resonance imaging (MRI) has been proposed for qualitative categorization of intraluminal thrombus morphology. We aimed to correlate the qualitative MRI categorization previously described to quantitative measurements of signal intensity and to compare morphological characteristics...

  8. Deep venous thrombus characterization: ultrasonography, elastography and scattering operator

    Directory of Open Access Journals (Sweden)

    Thibaud Berthomier

    2017-04-01

    Full Text Available A thrombus or a blood clot is the result of blood coagulation which is a natural process to prevent bleeding. An inappropriate formation of a thrombus in a deep vein is known as Deep Venous Thrombosis (DVT. The main complication of a DVT is a Pulmonary Embolism (PE which occurs when a thrombus breaks loose and travels to the lungs. DVT, PE, or both are also known as Venous thromboembolism (VTE. It affects an estimated 300,000–600,000 Individuals just in the United States per year and can cause considerable morbidity and mortality. This multifactorial disease related to advanced age, immobility, surgery or obesity is an important public health issue. Our project is looking to link the VTE epidemiology (risk factors, patient history, PE to the thrombus structure. To reach our goals, we are collecting ultrasonography (echogenicity and elastography (stiffness of human thrombus. This manuscript describes our approach to create and preprocess a database using Toshiba Aplio 500. Our approaches to characterize the thrombus structure with ultrasound images are also described. The feature extraction is made with the scattering operator. Obtained features are then reduced using Principal Component Analysis and are analyzed to evaluate our approach.

  9. BLEACHING NEPTUNE BALLS

    Directory of Open Access Journals (Sweden)

    BONET Maria Angeles

    2014-05-01

    Full Text Available Posidonia Oceanic is a seaweed from Mediterranean Sea and it is more concentrated at the Balerian SEA. This implies the Valencian Community also. It forms vaste underwater meadows in the sea and are part of the Mediterranean ecosystem. It is a sea-grass specie with fruits and flowers. Leaves are ribbon-like and they grow in winter and at the end of summer some of them are separated and arrive to some sea line. Fuit is separated and can floate, it is known as “the olive of the sea” mainly in Italy, or as the Neptune Balls. As it can be used in different fields, it is is being studied in order ro have the precitice tests. Some authors have reported the manufacturing of fully bio-based comites with a gluten matrix by hot-press molding. And it has been considered as an effective insulator for building industry or even though to determine the presence of mercure in the Mediterranean sea some years ago. As many applications can be designed from that fibers, it has been considered to be bleached in order to used them in fashionable products. Consequently, its original brown color is not the most suitable one and it should be bleached as many other cellulosic fibers. The aim of this paper is to bleache neptune balls however, the inner fibers were not accessible at all and it implied not to bleach the inner fibers in the neptune ball. Further studiesd will consider bleaching the individualized fibers.

  10. Dynamics of a Bouncing Ball

    Science.gov (United States)

    Liang, Shiuan-Ni; Lan, Boon Leong

    The dynamics of a bouncing ball undergoing repeated inelastic impacts with a table oscillating vertically in a sinusoidal fashion is studied using Newtonian mechanics and general relativistic mechanics. An exact mapping describes the bouncing ball dynamics in each theory. We show, contrary to expectation, that the trajectories predicted by Newtonian mechanics and general relativistic mechanics from the same parameters and initial conditions for the ball bouncing at low speed in a weak gravitational field can rapidly disagree completely. The bouncing ball system could be realized experimentally to test which of the two different predicted trajectories is correct.

  11. Individual ball possession in soccer.

    Directory of Open Access Journals (Sweden)

    Daniel Link

    Full Text Available This paper describes models for detecting individual and team ball possession in soccer based on position data. The types of ball possession are classified as Individual Ball Possession (IBC, Individual Ball Action (IBA, Individual Ball Control (IBC, Team Ball Possession (TBP, Team Ball Control (TBC und Team Playmaking (TPM according to different starting points and endpoints and the type of ball control involved. The machine learning approach used is able to determine how long the ball spends in the sphere of influence of a player based on the distance between the players and the ball together with their direction of motion, speed and the acceleration of the ball. The degree of ball control exhibited during this phase is classified based on the spatio-temporal configuration of the player controlling the ball, the ball itself and opposing players using a Bayesian network. The evaluation and application of this approach uses data from 60 matches in the German Bundesliga season of 2013/14, including 69,667 IBA intervals. The identification rate was F = .88 for IBA and F = .83 for IBP, and the classification rate for IBC was κ = .67. Match analysis showed the following mean values per match: TBP 56:04 ± 5:12 min, TPM 50:01 ± 7:05 min and TBC 17:49 ± 8:13 min. There were 836 ± 424 IBC intervals per match and their number was significantly reduced by -5.1% from the 1st to 2nd half. The analysis of ball possession at the player level indicates shortest accumulated IBC times for the central forwards (0:49 ± 0:43 min and the longest for goalkeepers (1:38 ± 0:58 min, central defenders (1:38 ± 1:09 min and central midfielders (1:27 ± 1:08 min. The results could improve performance analysis in soccer, help to detect match events automatically, and allow discernment of higher value tactical structures, which is based on individual ball possession.

  12. Study of 99Tcm-annexin V distribution in inferior vena cava thrombus models of rabbits

    International Nuclear Information System (INIS)

    Wu Dayong; Zhang Wenyan; Bian Yanzhu; Hu Yujing

    2013-01-01

    To study 99 Tc m -Annexin V distribution in inferior vena cava thrombus models of rabbits and uptake of 99 Tc m -Annexin V in fresh and old venous thrombus. Rabbits (n=15) were randomly grouped into 3 groups (the fresh thrombus group, old thrombus group, and control group). The rabbits of two thrombus groups developed inferior vena cava thrombus models by operations. The control group received sham operation. The fresh thrombus group and control group rabbits were injected 99 Tc m -Annexin V after operating 1 d; the old thrombus group 14 d. After 1 h all rabbits were killed by injecting overdose pentobarbital sodium. The thrombus (or the inferior vena cava about 3 cm below inferior pole of right kidney level in the control group rabbits), blood, thrombus area inferior vena cava, head lateral inferior vena cava (except the control group), thigh muscle, stomach, myocardium, pulmonary, liver, kidney, spleen, bone and small intestine were obtained from all group rabbits. The ex tissue and blood were weighed and measured by a Well-type detector. The percentage of the injected dose per gram of ex tissue (or blood) was calculated by the above data. The thrombus to blood, thrombus area inferior vena cava, head lateral inferior vena cava and thigh muscle ratios were calculated by percentage of the injected dose per gram of ex tissue (or blood). The test was used to compare the fresh thrombus group and old thrombus group by SPSS 17.0. The percentage of' the injected dose per gram of thrombi (0.01894± 0.002 16% ID/g) in the fresh thrombus group was higher than the old thrombus group (0.00473±0.001 28% ID/g), P<0.05. The thrombus to blood, thrombus area inferior vena cava, head lateral inferior vena cava and muscle ratios (3.42±1.06, 26.32±13.60, 31.23 ±16.00, 111.62±52.23) in the fresh thrombus group were higher than the old thrombus group (0.98±0.09, 5.12±2.01, 6.25±2.38, 21.82±5.93), P<0.05 for all. All the thrombi of the fresh thrombus group were confirmed

  13. Oclusão percutânea do apêndice atrial esquerdo com o Amplatzer Cardiac PlugTM na fibrilação atrial Percutaneous occlusion of left atrial appendage with the Amplatzer Cardiac PlugTM in atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Márcio José Montenegro

    2012-02-01

    , anticoagulation has several limitations and has been widely underutilized. Over 90% of thrombi identified in patients with atrial fibrillation without valvular disease originate in the left atrial appendage, whose occlusion is investigated as an alternative to anticoagulation. Objective: To determine the feasibility of percutaneous occlusion of the left atrial appendage in patients at high risk of embolic events and limitations to the use of anticoagulation. Methods: We report our initial experience with Amplatzer Cardiac PlugTM (St. Jude Medical Inc., Saint Paul, Estados Unidos in patients with nonvalvular atrial fibrillation. We selected patients at high risk of thromboembolism, major bleeding, contraindications to the use or major instability in response to the anticoagulant. The procedures were performed percutaneously under general anesthesia and transesophageal echocardiography. The primary outcome was the presence of periprocedural complications and follow-up program included clinical and echocardiographic review within 30 days and by telephone contact after nine months. Results: In five selected patients it was possible to occlude the left atrial appendage without periprocedural complications. There were no clinical events in follow-up. Conclusion: Controlled clinical trials are needed before percutaneous closure of the left atrial appendage should be considered an alternative to anticoagulation in nonvalvular atrial fibrillation. But the device has shown to be promissory in patients at high risk of embolism and restrictions on the use of anticoagulants.

  14. Experimental research on ball lightning

    International Nuclear Information System (INIS)

    Ofuruton, H.; Ohtsuki, Y.H.

    1990-01-01

    Experiments on producing ball lightning were made with discharge in flammable gas and/or aerosol. A long lifetime (2 s) ball lightning was observed in 2.7 % ethane and 100 cm 3 cotton fibers, and in 1.5 % methane and 1.9 % ethane

  15. Contemporary management of symptomatic primary aortic mural thrombus.

    Science.gov (United States)

    Verma, Himanshu; Meda, Narendranadh; Vora, Simit; George, Robbie K; Tripathi, Ramesh K

    2014-12-01

    Primary aortic mural thrombus (PAMT) is an uncommon condition but an important source of noncardiogenic emboli with a difficult diagnosis and a high rate of complications, including high mortality. We report our experience of thromboembolic disease from PAMT and review its contemporary management. Retrospective analysis of prospectively collected data of all patients who presented with acute occlusion of a limb or visceral vessels between January 2011 and September 2013 was performed. A total of 88 patients presented with acute occlusion of the extremities or visceral arteries. All underwent extensive evaluation for the possible source of the embolism. Of these 88 patients, 19 patients (mean age, 41.2 years; male:female ratio, 1:2.1) were found to have aortic mural thrombus as the source of distal embolism. Thrombus was located in the thoracic aorta in 10 patients, in the perivisceral aorta in three patients, and in the infrarenal aorta in six patients. Thrombus in the thoracic aorta was treated with stent grafts in four patients, bare metal stents in three patients, and anticoagulation alone in two patients. In the suprarenal abdominal aorta, all three patients underwent trapdoor aortic thrombectomy. Infrarenal aortic thrombus was managed by aortobifemoral embolectomy in two patients, aortic stenting in two patients, surgical thrombectomy in one patient, and anticoagulation alone in one patient. Successful treatment, defined as freedom from further embolic events or recurrence of thrombus, was achieved in 14 of 19 patients (76.4%) with a mean follow-up period of 16.2 months (range, 2-28 months). There were four (21%) thrombus-related deaths, all due to primary thromboembolic insults. One patient needed a below-knee amputation because of a recurrent thrombotic episode. Symptomatic PAMT is an uncommon but important source of noncardiogenic embolus. It appears to occur more frequently in young women. Endovascular coverage of the aortic thrombus, when feasible

  16. PKCalpha regulates platelet granule secretion and thrombus formation in mice.

    Science.gov (United States)

    Konopatskaya, Olga; Gilio, Karen; Harper, Matthew T; Zhao, Yan; Cosemans, Judith M E M; Karim, Zubair A; Whiteheart, Sidney W; Molkentin, Jeffery D; Verkade, Paul; Watson, Steve P; Heemskerk, Johan W M; Poole, Alastair W

    2009-02-01

    Platelets are central players in atherothrombosis development in coronary artery disease. The PKC family provides important intracellular mechanisms for regulating platelet activity, and platelets express several members of this family, including the classical isoforms PKCalpha and PKCbeta and novel isoforms PKCdelta and PKCtheta. Here, we used a genetic approach to definitively demonstrate the role played by PKCalpha in regulating thrombus formation and platelet function. Thrombus formation in vivo was attenuated in Prkca-/- mice, and PKCalpha was required for thrombus formation in vitro, although this PKC isoform did not regulate platelet adhesion to collagen. The ablation of in vitro thrombus formation in Prkca-/- platelets was rescued by the addition of ADP, consistent with the key mechanistic finding that dense-granule biogenesis and secretion depend upon PKCalpha expression. Furthermore, defective platelet aggregation in response to either collagen-related peptide or thrombin could be overcome by an increase in agonist concentration. Evidence of overt bleeding, including gastrointestinal and tail bleeding, was not seen in Prkca-/- mice. In summary, the effects of PKCalpha ablation on thrombus formation and granule secretion may implicate PKCalpha as a drug target for antithrombotic therapy.

  17. Crystal Ball at PEP

    International Nuclear Information System (INIS)

    Bartel, W.; Bulos, F.; Luke, D.; Peck, C.; Strauch, K.

    1975-01-01

    The modifications to the SPEAR version of the Crystal Ball required by the higher energies at PEP are discussed. Since the hadron multiplicity is expected to rise as log s, their average energy must rise. On the other hand, if the hadrons are produced in jets, the low energy part of their spectrum is not heavily depleted. This implies that modifications for high energy particles should not deteriorate low energy performance. An external iron calorimeter for measuring the high energy hadrons, charged and neutral, is considered. To improve the angular resolution on γ's, an active internal converter has been studied, estimates have been made of its expected performance, and difficulties requiring further study have been outlined

  18. Traversing boundaries: thrombus in transit with paradoxical embolism

    Directory of Open Access Journals (Sweden)

    Varun Miriyala

    2016-09-01

    Full Text Available A 72-year-old male is diagnosed with paradoxical embolus after he presented with concurrent deep vein thrombosis, stroke, and multiple arterial emboli in the presence of a patent foramen ovale (PFO. Paradoxical embolus requires the passage of a thrombus from the venous into the arterial circulation through a right-to-left shunt leading to systemic embolism. But, despite the high incidence of PFO (27.3% across all age groups by autopsy, paradoxical embolism (PDE is uncommon, representing <2% of all arterial emboli. We present a case report where a thrombus has been directly observed passing through the PFO during an echocardiogram study; thus, clearly delineating the true cause of multiple thromboemboli and stoke in our patient. Subsequent Transesophageal Echocardiography (TEE also interestingly showed the thrombus in transit in the aorta and pulmonary artery.

  19. Method of cell transplantation promoting the organization of intraarterial thrombus.

    Science.gov (United States)

    Hirano, Koji; Shimono, Takatsugu; Imanaka-Yoshida, Kyoko; Miyamoto, Keiichi; Fujinaga, Kazuya; Kajimoto, Masaki; Miyake, Yoichiro; Nishikawa, Masakatsu; Yoshida, Toshimichi; Uchida, Atsumasa; Shimpo, Hideto; Yada, Isao; Hirata, Hitoshi

    2005-08-30

    Endovascular aortic repairs have been developed as less invasive treatments for aortic aneurysms. Some aneurismal cavities, however, remain without organization, causing a re-expansion of the aneurysms. We studied cell transplantation into the aneurismal sac to promote the organization of thrombus for the complete healing of aneurysms. Skin fibroblasts and skeletal myoblasts were isolated from rats for cell transplantation. An intraarterial thrombus model was made by ligation of the carotid artery. Culture medium (medium group, n=11), collagen gel (gel group, n=11), fibroblasts with collagen gel (F group, n=15), myoblasts with collagen gel (M group, n=12), or mixture of fibroblasts and myoblasts with collagen gel (F+M group, n=14) were injected into the thrombus. After 28 days, histologically, the arterial lumens of the F and M groups were partly filled with fibrous tissues, whereas in the F+M group organization was almost completed and luminal sizes diminished. Immunohistochemical staining demonstrated that alpha-smooth muscle actin-positive cells were more abundantly contained in the organized area of the F+M group than in the other groups. We also analyzed cellular function in vitro with immunofluorescence; coculture of fibroblasts and myoblasts showed that the fraction of alpha-smooth muscle actin-positive fibroblasts increased. This phenomenon accounts for the rapid organization of thrombus in the F+M group in vivo. Cell transplantation accelerated thrombus organization. Especially, myoblasts enhanced differentiation of fibroblasts into myofibroblasts, contributing to rapid thrombus organization. Cell transplantation into unorganized spaces seems applicable to endovascular treatment of aneurysms.

  20. Floating arterial thrombus related stroke treated by intravenous thrombolysis.

    Science.gov (United States)

    Vanacker, P; Cordier, M; Janbieh, J; Federau, C; Michel, P

    2014-01-01

    The effects of intravenous thrombolysis on floating thrombi in cervical and intracranial arteries of acute ischemic stroke patients are unknown. Similarly, the best prevention methods of early recurrences remain controversial. This study aimed to describe the clinical and radiological outcome of thrombolyzed strokes with floating thrombi. We retrospectively analyzed all thrombolyzed stroke patients in our institution between 2003 and 2010 with floating thrombi on acute CT-angiography before the intravenous thrombolysis. The floating thrombus was diagnosed if an elongated thrombus of at least 5 mm length, completely surrounded by contrast on supra-aortic neck or intracerebral arteries, was present on CT-angiography. Demographics, vascular risk factors, and comorbidities were recorded and stroke etiology was determined after a standardized workup. Repeat arterial imaging was performed by CTA at 24 h or before if clinical worsening was noted and then by Doppler and MRA during the first week and at four months. Of 409 thrombolyzed stroke patients undergoing acute CT Angiography, seven (1.7%) had a floating thrombus; of these seven, six had it in the anterior circulation. Demographics, risk factors and stroke severity of these patients were comparable to the other thrombolyzed patients. After intravenous thrombolysis, the floating thrombi resolved completely at 24 h in four of the patients, whereas one had an early recurrent stroke and one developed progressive worsening. One patient developed early occlusion of the carotid artery with floating thrombus and subsequently a TIA. The two patients with a stable floating thrombus had no clinical recurrences. In the literature, only one of four reported cases were found to have a thrombolysis-related early recurrence. Long-term outcome seemed similar in thrombolyzed patients with floating thrombus, despite a possible increase of very early recurrence. It remains to be established whether acute mechanical thrombectomy could be

  1. A thrombus in transit through a patent foramen ovale.

    Science.gov (United States)

    Ibebuogu, Uzoma N; Khouzam, Rami N; Sharma, Gyanendra; Thornton, John W; Robati, Roshanak; Silverman, David

    2014-10-01

    Patent foramen ovale (PFO) is a congenital heart defect that may first be diagnosed in adulthood and has a prevalence of 25% to 30%. Although many patients with PFO are asymptomatic and do not require treatment, paradoxical embolism can cause stroke or myocardial infarction. The authors report an unusual case of PFO with a transversing thrombus in an 80-year-old man. The patient's initial presentation appeared clinically as acute coronary syndrome, but he was subsequently diagnosed with a massive thrombus in transit via a PFO and pulmonary embolus leading to right-sided heart failure.

  2. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    NARCIS (Netherlands)

    Santos, Emilie M. M.; Yoo, Albert J.; Beenen, Ludo F.; Berkhemer, Olvert A.; den Blanken, Mark D.; Wismans, Carrie; Niessen, Wiro J.; Majoie, Charles B.; Marquering, Henk A.; Fransen, Puck S. S.; Beumer, Debbie; van den Berg, Lucie A.; Lingsma, Hester F.; Schonewille, Wouter J.; Vos, Jan Albert; Nederkoorn, Paul J.; Wermer, Marieke J. H.; van Walderveen, Marianne A. A.; Staals, Julie; Hofmeijer, Jeannette; van Oostayen, Jacques A.; Lycklama à Nijeholt, Geert J.; Boiten, Jelis; Brouwer, Patrick A.; Emmer, Bart J.; de Bruijn, Sebastiaan F.; van Dijk, Lukas C.; Kappelle, L. Jaap; Lo, Rob H.; van Dijk, Ewoud J.; de Vries, Joost; de Kort, Paul L. M.; van den Berg, Jan S. P.; A A M van Hasselt, Boudewijn; Aerden, Leo A. M.; Dallinga, René J.; Visser, Marieke C.; Bot, Joseph C. J.; Vroomen, Patrick C.; Eshghi, Omid; Schreuder, Tobien H. C. M. L.; Heijboer, Roel J. J.; Keizer, Koos; Tielbeek, Alexander V.; Hertog, Heleen M. Den; Gerrits, Dick G.; van den Berg-Vos, Renske M.; Karas, Giorgos B.; Steyerberg, Ewout W.; Flach, H. Zwenneke; Sprengers, Marieke E. S.; Jenniskens, Sjoerd F. M.; van den Berg, René; Koudstaal, Peter J.; van Zwam, Wim H.; Roos, Yvo B. W. E. M.; van der Lugt, Aad; van Oostenbrugge, Robert J.; Dippel, Diederik W. J.

    2016-01-01

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert

  3. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    NARCIS (Netherlands)

    E.M.M. Santos (Emilie M.); A.J. Yoo (Albert J.); L.F.M. Beenen (Ludo); O.A. Berkhemer (Olvert); M.D. Den Blanken (Mark D.); C. Wismans (Carrie); W.J. Niessen (Wiro); C.B. Majoie (Charles); H. Marquering (Henk)

    2016-01-01

    textabstractIntroduction: Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by

  4. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    NARCIS (Netherlands)

    Santos, E.M.; Yoo, A.J.; Beenen, L.F.; Berkhemer, O.A.; Blanken, M.D. den; Wismans, C.; Niessen, W.J.; Majoie, C.B.; Marquering, H.A.; Dijk, E.J. van; et al.,

    2016-01-01

    INTRODUCTION: Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and

  5. Noninvasive diagnosis of thrombus in the heart and large vessels

    International Nuclear Information System (INIS)

    Masuda, Yoshiaki; Morooka, Nobuhiro; Yoshida, Hideo; Watanabe, Shigeru; Inagaki, Yoshiaki

    1984-01-01

    The usefulness of two dimensional echocardiography (2-D echocardiography) and x-ray computed tomography (CT) for the diagnosis of thrombi in the cardiac cavity and large vessels was studied by comparing them with the findings of invasive methods. Among 56 subjects with mitral stenosis, left atrial thrombi were noted in 12 cases (16 regions) by CT and 8 cases (9 regions) by 2-D echocardiography. In 16 subjects who underwent operations, one false negative case by CT and 3 false negative and one false positive cases by 2-D echocardiography were found. In 80 subjects with myocardial infarction 2-D echocardiography, CT and left ventriculography (LVG) were performed at approximately the same time. Thrombi were detected in 10 subjects (12.5%) by 2-D echocardiography, in 15 (18.8%) by CT and in 14 (17.5%) by LVG. Although mural thrombi in abdominal aortic aneurysm were detected very easily, thin thrombi surrounding the false lumen of the dissecting aneurysm were not detected ultrasonographically. These thrombi were only detected by the enhanced CT. Our results show the usefulness of both methods for detecting thrombi in the heart and large vessels. CT can distinguish the thrombi more clearly than 2-D echocardiography, but 2-D echocardiography is performed more easily, safely and economically than CT. (author)

  6. Thrombus scintigraphy with Ga-67 DFO-DAS-Fibrinogen, 2

    International Nuclear Information System (INIS)

    Kawasaki, Yukiko

    1987-01-01

    In our previous in vivo study 67 Ga DFO-DAS-Fibrinogen was assessed for its usefulness as a radiopharmaceutical for the detection of thrombin in experimental animals (Report 1). The present study was undertaken to appraise the diagnostic value of 67 Ga DFO-DAS-Fibrinogen in human disease, especially in relation to blood coagulability as well as to thrombolytic drug regimen being given, in an effort to investigate its clinical applicability. Involved in this study were 48 patients with thrombosis proven by X-ray CT and other examinations. Of these 48, 42 had arterial thrombosis (20 with aortic aneurysm including the dissecting form, 11 in postoperative condition following vascular surgery with a prosthesis, 9 with intracardiac thrombosis accompanying heart disease, and 1 each with occlusive arteriosclerosis and cerebral infarction) and 6 had venous thrombosis. The 67 Ga DFO-DAS-Fibrinogen test proved to be positive in 55 % of arterial thrombin and in 50 % of venous thrombin. It is interesting to note that as high a positivity rate as 80 % was obtained for aortic aneurysm, although the positivity rate was disappointingly low for left atrial thrombin. No distinct correlation was noted to exist between the degree of accumulation of the tracer in thrombotic lesions and any of factors conceivably of clinical releavance, i.e. time elapsing from onset till testing, thrombolytic medication being given, and hematological factors. 67 Ga DFO-DAS-Fibrinogen appeared to be a radiodiagnostic agent that could possibly indicate the existing activity status of thrombosis. (author)

  7. LHC gets the ball rolling

    CERN Multimedia

    2007-01-01

    A technique involving a small ball with a transmitter embedded inside it has been successfully tested in Sector 7-8. The ball is sent through the LHC beam pipes to check the LHC interconnections. The multidisciplinary team responsible for the RF ball project to check the interconnections. From left to right: Rhodri Jones (AB/BI), Eva Calvo (AB/BI), Francesco Bertinelli (AT/MCS), Sonia Bartolome Jimenez (TS/IC), Sylvain Weisz (TS/IC), Paul Cruikshank (AT/VAC), Willemjan Maan (AT/VAC), Alain Poncet (AT/MCS), Marek Gasior (AB/BI). During the tests the ball is inserted very carefully into the vacuum chamber.A game of ping-pong at the LHC? On 13 September a rather unusual test was carried out in Sector 7-8 of the accelerator. A ball just a bit smaller than a ping-pong ball was carefully introduced into one of the accelerator’s two vacuum pipes, where it travelled 800 metres in the space of a few mi...

  8. Erythrocyte membrane modified janus polymeric motors for thrombus therapy

    NARCIS (Netherlands)

    Shao, Jingxin; Abdelghani, Mona; Shen, Guizhi; Cao, Shoupeng; Williams, David S.; van Hest, Jan C.M.

    2018-01-01

    We report the construction of erythrocyte membrane-cloaked Janus polymeric motors (EM-JPMs) which are propelled by near-infrared (NIR) laser irradiation and are successfully applied in thrombus ablation. Chitosan (a natural polysaccharide with positive charge, CHI) and heparin (glycosaminoglycan

  9. Metastatic Adenocarcinoma Presenting as Extensive Cavoatrial Tumor Thrombus

    International Nuclear Information System (INIS)

    Johari, Bushra; Abdul Aziz, Yang Faridah; Krishnasamy, Sivakumar; Looi, Lai Meng; Hashim, Shahrul Amry; Raja Mokhtar, Raja Amin

    2015-01-01

    The presence of tumor thrombus in the right atrium is frequently the result of direct intraluminal extension of infra-diaphragmatic malignancy into the inferior vena cava (IVC) or supradiaphragmatic carcinoma into the superior vena cava (SVC). Right atrial tumor thrombus with extension into both SVC and IVC has not been reported in the literature. We present a patient who presented with symptoms of right atrial and SVC obstruction. Imaging revealed presence of a thrombus in the right atrium, extending to the SVC and IVC, with the additional findings of a left adrenal mass and multiple liver lesions. The histopathological examination of the right atrial mass revealed metastatic adenocarcinoma cells. The patient was given a presumptive diagnosis of metastatic adenocarcinoma, most likely adrenal in origin, with multiple hepatic lesions suspicious for metastasis. The clinical outcome of the patient was not favorable; the patient succumbed before the adrenal mass could be confirmed to be the primary tumor. This case highlights that in patients manifesting with extensive cavoatrial thrombus as, the existence of primary carcinoma should be considered especially in the adrenal cortex or in the lung

  10. Added value of multiphase CTA imaging for thrombus perviousness assessment

    Energy Technology Data Exchange (ETDEWEB)

    Santos, E.M.M. [Academic Medical Center, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Erasmus Medical Center, Department of Medical Informatics, Rotterdam (Netherlands); D' Esterre, C.D.; Najm, M.; Goyal, M.; Demchuk, A.M.; Menon, B.K. [University of Calgary, Departments of Neurosciences, Radiology and Community Health Sciences, Calgary (Canada); Treurniet, K.M.; Majoie, C.B. [Academic Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Niessen, W.J. [Erasmus Medical Center, Department of Medical Informatics, Rotterdam (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Marquering, H.A. [Academic Medical Center, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Academic Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Mandzia, Jennifer; Fainardi, Enrico; Rubiera, Marta; Khaw, Alexander V.; Zini, Andrea; Shankar, JJ.; Collaboration: PRove-IT investigators

    2018-01-15

    Thrombus perviousness has been associated with favorable functional outcome in acute ischemic stroke (AIS) patients. Measuring thrombus perviousness on CTA may be suboptimal due to potential delay in contrast agent arrival in occluded arteries at the moment of imaging. Dynamic sequences acquired over time can potentially overcome this issue. We investigate if dynamic CTA has added value in assessing thrombus perviousness. Prospectively collected image data of AIS patients with proven occlusion of the anterior or posterior circulation with thin-slice multi-phase CTA (MCTA) and non-contrast CT were co-registered (n = 221). Thrombus attenuation increase (TAI; a perviousness measure) was measured for the arterial, venous, and delayed phase of the MCTA and time-invariant CTAs (TiCTA). Associations with favorable clinical outcome (90-day mRS ≤ 2) were assessed using univariate and multivariable regressions and calculating areas under receiver operating curves (AUC). TAI determined from the arterial phase CTA was superior in the association with favorable outcome with OR = 1.21 per 10 HU increase (95%CI 1.04-1.41, AUC 0.62, p = 0.014) compared to any other phase (venous 1.14(95%CI 1.01-1.30, AUC 0.58, p = 0.033), delayed 1.046(95%CI 0.919-1.19, AUC 0.53, p = 0.50)), and TiCTA 1.15(95%CI 1.02-1.30, AUC 0.60, p = 0.022). In the multivariable model, only TAI on arterial phase was significantly associated with favorable outcome (aOR 1.59, 95%CI 1.04-2.43, p = 0.032). Association between TAI with functional outcome was optimal on arterial-phase CTA such that dynamic CTA imaging has no additional benefits in current thrombus perviousness assessment, thereby suggesting that the delay of contrast arrival at the clot is a key variable for patient functional outcome. (orig.)

  11. Defeito do anel fibroso mitral posterior com aneurisma de átrio esquerdo e insuficiência mitral: tratamento cirúrgico com sucesso Defect of the posterior mitral fibrous ring with left atrial aneurysm and mitral insufficiency: successful surgical treatment

    Directory of Open Access Journals (Sweden)

    Ronaldo Machado BUENO

    1999-10-01

    Full Text Available Aneurismas em átrio esquerdo são pouco comuns, podendo ocorrer na aurícula ou na parede do átrio esquerdo. Freqüentemente, são assintomáticos, podendo ocorrer arritmias, fenômenos tromboembólicos ou insuficiência cardíaca como complicação da sua evolução. Apresentamos paciente de 39 anos, do sexo feminino, com defeito do anel posterior da valva mitral levando a grande dilatação aneurismática da parede posterior do átrio esquerdo com insuficiência mitral. O diagnóstico foi feito pela radiografia de tórax (abaulamento de silhueta cardíaca esquerda e ecocardiograma (grande aneurisma do átrio esquerdo posteriormente à parede posterior do ventrículo esquerdo com insuficiência mitral. O estudo hemodinâmico sugeriu pseudo-aneurisma de ventrículo esquerdo. Submetida a tratamento cirúrgico com auxílio da circulação extracorpórea, realizou-se anuloplastia mitral e exclusão do aneurisma com reconstrução do assoalho do átrio esquerdo com retalho de pericárdio bovino. A paciente apresentou boa evolução pós-operatória, recebendo alta hospitalar no oitavo dia em boas condições clínicas.Atrial aneurysm is a rare condition and can be found on the atrial appendage or on the atrial wall. Most patients are asymptomatic, but arrhythmias, thromboembolism, and heart failure are common complications. We present a 39 years old female patient with posterior mitral ring defect causing a great aneurysm of the left posterior atrial wall with mitral insufficiency. The diagnosis was achieved by chest roentgenogram (marked prominence of the upper left heart border and echocardiography (great left atrial aneurysm behind the left posterior ventricular wall with mitral insufficiency. Left ventricular cineangiogram suggested the presence of a false aneurysm of the left ventricle. The patient subsequently underwent surgical treatment with cardiopulmonary bypass. Posterior mitral valve annuloplasty was performed with aneurysm exclusion

  12. Berkeley High-Resolution Ball

    International Nuclear Information System (INIS)

    Diamond, R.M.

    1984-10-01

    Criteria for a high-resolution γ-ray system are discussed. Desirable properties are high resolution, good response function, and moderate solid angle so as to achieve not only double- but triple-coincidences with good statistics. The Berkeley High-Resolution Ball involved the first use of bismuth germanate (BGO) for anti-Compton shield for Ge detectors. The resulting compact shield permitted rather close packing of 21 detectors around a target. In addition, a small central BGO ball gives the total γ-ray energy and multiplicity, as well as the angular pattern of the γ rays. The 21-detector array is nearly complete, and the central ball has been designed, but not yet constructed. First results taken with 9 detector modules are shown for the nucleus 156 Er. The complex decay scheme indicates a transition from collective rotation (prolate shape) to single- particle states (possibly oblate) near spin 30 h, and has other interesting features

  13. Prediction of thrombus-related mechanical prosthetic valve dysfunction using transesophageal echocardiography

    Science.gov (United States)

    Lin, S. S.; Tiong, I. Y.; Asher, C. R.; Murphy, M. T.; Thomas, J. D.; Griffin, B. P.

    2000-01-01

    Identification of thrombus-related mechanical prosthetic valve dysfunction (MPVD) has important therapeutic implications. We sought to develop an algorithm, combining clinical and echocardiographic parameters, for prediction of thrombus-related MPVD in a series of 53 patients (24 men, age 52 +/- 16 years) who had intraoperative diagnosis of thrombus or pannus from 1992 to 1997. Clinical and echocardiographic parameters were analyzed to identify predictors of thrombus and pannus. Prevalence of thrombus and diagnostic yields relative to the number of predictors were determined. There were 22 patients with thrombus, 19 patients with pannus, and 12 patients with both. Forty-two of 53 masses were visualized using transesophageal echocardiography (TEE), including 29 of 34 thrombi or both thrombi and panni and 13 of 19 isolated panni. Predictors of thrombus or mixed presentation include mobile mass (p = 0.009), attachment to occluder (p = 0.02), elevated gradients (p = 0.04), and an international normalized ratio of or = 1 predictor. The prevalence of thrombus in the presence of or = 3 predictors is 14%, 69%, and 91%, respectively. Thus, TEE is sensitive in the identification of abnormal mass in the setting of MPVD. An algorithm based on clinical and transesophageal echocardiographic predictors may be useful to estimate the likelihood of thrombus in the setting of MPVD. In the presence of > or = 3 predictors, the probability of thrombus is high.

  14. Evaluation of the thrombus of abdominal aortic aneurysms using contrast enhanced ultrasound - preliminary results

    Science.gov (United States)

    Łukasiewicz, Adam; Garkowski, Adam; Rutka, Katarzyna; Janica, Jacek; Łebkowska, Urszula

    2016-09-01

    It is hypothesized that the degree of vascularization of the thrombus may have a significant impact on the rupture of aortic aneurysms. The presence of neovascularization of the vessel wall and mural thrombus has been confirmed only in histopathological studies. However, no non-invasive imaging technique of qualitative assessment of thrombus and neovascularization has been implemented so far. Contrast-enhanced ultrasound (CEUS) has been proposed as a feasible and minimally invasive technique for in vivo visualization of neovascularization in the evaluation of tumors and atherosclerotic plaques. The aim of this study was the evaluation of mural thrombus and AAAs wall with CEUS. CEUS was performed in a group of seventeen patients with AAAs. The mural thrombus enhancement was recognized in 12 cases, yet no significant correlation between the degree of contrast enhancement and AAAs diameter, thrombus width, and thrombus echogenicity was found. We observed a rise in AAAs thrombus heterogeneity with the increase in the aneurysm diameter (r = 0.62, p = 0.017). In conclusion CEUS can visualize small channels within AAAs thrombus, which could be a result of an ongoing angiogenesis. There is a need for further research to find out whether the degree of vascularization of the thrombus may have a significant impact on the rupture of aneurysms.

  15. Surgical Treatment for Thrombus Straddling a Patent Foramen Ovale

    Directory of Open Access Journals (Sweden)

    Marcos Aurélio Barboza de Oliveira

    Full Text Available Abstract We present a case of a 41-year-old female with deep vein thrombosis after abdominal surgery. The patient quickly developed severe pulmonary embolism and stroke representative of paradoxical embolism. Echocardiography showed a thrombus straddling a patent foramen ovale, which was confirmed intraoperatively. An accurate diagnosis and rapid treatment decisions are crucial for preventing patient deterioration in the form of new pulmonary embolisms or stroke.

  16. Imaging thrombus with radiolabelled monoclonal antibody to platelets

    International Nuclear Information System (INIS)

    Loutfi, I.; Peters, A.M.; Lavender, J.P.; Epenetos, A.A.

    1988-01-01

    Indium-111-hydroxyquinoline labelled platelets, though useful in the detection of thrombus, have not gained widespread use owing to the time and technical skill required for their preparation. A study was therefore conducted evaluating a new method of imaging thrombus with platelets radiolabelled with a 111 In labelled monoclonal antibody, P 256 , directed to the platelet surface glycoprotein complex IIb/IIIa. When the number of receptors occupied by P 256 was less than 3% of the total available on the platelet surface platelet function, as assessed by platelet aggregometry, was undisturbed. P 256 was radiolabelled with 111 In using diethylenetriaminepenta-acetic acid, which achieved a specific activity of 185 MBq (5 mCi)/mg. No impairment of immunoreactivity was detected at this specific activity. Platelets were labelled with radiolabelled monoclonal antibody in vitro in two patients at a receptor occupancy of 6% and in vivo - that is, by direct intravenous injection of P 256 - in six patients at a receptor occupancy of 1%. In vivo recovery and biodistribution kinetics suggested that after in vitro labelling platelets were minimally activated. The 111 In kinetics recorded after intravenous P 256 suggested rapid and efficient radiolabelling of platelets and gave no indication of platelet activation. Of the six patients who received intravenous P 256 , three had documented thrombus, tow of whom gave positive results on P 256 platelet scintigraphy. The third subject had chromic deep venous thrombosis and was scintigraphically negative. Imaging thrombus using a radiolabelled monoclonal antibody directed to platelets appears to offer great potential as a simple, non-invasive approach to the diagnosis of thrombosis. 3 refs. (Author)

  17. Ultrasound active nanoscaled lipid formulations for thrombus lysis.

    Science.gov (United States)

    Becker, Andreas; Marxer, Elena; Brüssler, Jana; Hoormann, Anne Sophia; Kuhnt, Daniela; Bakowsky, Udo; Nimsky, Christopher

    2011-04-01

    In the present study, we investigated the sonothrombolytic effect of new nanoscaled lipid formulations in human blood clots, using diagnostic ultrasound. Human blood clots of 1 ml were incubated with 1 μl of the different lipid dispersions DPPC/CH, DPPC/PEG40S, DSPC/PEG40S and the commercially available ultrasound contrast agent SonoVue®. Clots were stored for 3 days at 5 °C to obtain maximal clot retraction and lytic resistance. Each clot weight was determined before and after continuous insonation for 1h of insonation at 1.4 MHz. The pressure in the insonation chamber was 80 mm Hg to mimic middle arterial blood pressure. There were no significant differences in thrombus weight before insonation. All nanoscaled formulations and SonoVue® were able to reduce thrombus weight compared to the weight loss of clots that were not insonated but kept under pressure for one hour (p ultrasound enhanced thrombolysis even without thrombolytic drugs. Stable cavitation is a crucial parameter in fragmentation of thrombus architecture. Further studies of physicochemical properties of DSPC/PEG40S are necessary to corroborate our hypothesis. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. LHC gets the ball rolling

    CERN Multimedia

    2007-01-01

    1. The multidisciplinary team responsible for the RF ball project to check the interconnections. From left to right: Rhodri Jones (AB/BI), Eva Calvo (AB/BI), Francesco Bertinelli (AT/MCS), Sonia Bartolome Jimenez (TS/IC), Sylvain Weisz (TS/IC), Paul Cruikshank (AT/VAC), Willemjan Maan (AT/VAC), Alain Poncet (AT/MCS), Marek Gasior (AB/BI).2. During the tests the ball is inserted very carefully into the vacuum chamber.1. Le groupe pluridisciplinaire qui a mené le projet de balle RF pour vérifier les interconnexions avec, de gauche à droite, Rhodri Jones (AB/BI), Eva Calvo (AB/BI), Francesco Bertinelli (AT/MCS), Sonia Bartolome Jimenez (TS/IC), Sylvain Weisz (TS/IC), Paul Cruikshank (AT/VAC), Willemjan Maan (AT/VAC), Alain Poncet (AT/MCS) et Marek Gasior (AB/BI).2. Lors des tests, la balle est insérée dans la chambre à vide avec beaucoup de précaution.

  19. The correct "ball bearings" data.

    Science.gov (United States)

    Caroni, C

    2002-12-01

    The famous data on fatigue failure times of ball bearings have been quoted incorrectly from Lieblein and Zelen's original paper. The correct data include censored values, as well as non-fatigue failures that must be handled appropriately. They could be described by a mixture of Weibull distributions, corresponding to different modes of failure.

  20. Reflections on a Disco Ball

    Science.gov (United States)

    Ribeiro, Jair Lúcio Prados

    2016-01-01

    A disco ball is a spherical object covered with small plane mirrors. When light reflects on these mirrors, it is scattered in many directions, producing a novel effect. The mirror globe is usually set to rotate, creating a profusion of moving spots (Fig. 1). In this article, we present a geometrical description of the movement of these spots and…

  1. Encapsulated Ball Bearings for Rotary Micro Machines

    Science.gov (United States)

    2007-01-01

    occurrence as well as the overall tribological properties of the bearing mechanism. Firstly, the number of stainless steel balls influences not only the load...stacks.iop.org/JMM/17/S224 Abstract We report on the first encapsulated rotary ball bearing mechanism using silicon microfabrication and stainless steel balls...The method of capturing stainless steel balls within a silicon race to support a silicon rotor both axially and radially is developed for rotary micro

  2. 2012 Problem 15: Frustrating Golf Ball

    Science.gov (United States)

    Huang, Shan; Zhu, Zheyuan; Gao, Wenli; Wang, Sihui

    2015-10-01

    This paper studies the condition for a golf ball to escape from a hole. The two determining factors are the ball's initial velocity v0 and its deviation from the center of the hole d. There is a critical escaping velocity vc for every deviation d. The ball's motion is analyzed by calculating the change of velocity whenever the ball collides with the hole. The critical conditions predicted by our theory are verified through experiment.

  3. Ceramic ball grid array package stress analysis

    Science.gov (United States)

    Badri, S. H. B. S.; Aziz, M. H. A.; Ong, N. R.; Sauli, Z.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    The ball grid array (BGA), a form of chip scale package (CSP), was developed as one of the most advanced surface mount devices, which may be assembled by an ordinary surface ball bumps are used instead of plated nickel and gold (Ni/Au) bumps. Assembly and reliability of the BGA's printed circuit board (PCB), which is soldered by conventional surface mount technology is considered in this study. The Ceramic Ball Grid Array (CBGA) is a rectangular ceramic package or square-shaped that will use the solder ball for external electrical connections instead of leads or wire for connections. The solder balls will be arranged in an array or grid at the bottom of the ceramic package body. In this study, ANSYS software is used to investigate the stress on the package for 2 balls and 4 balls of the CBGA package with the various force range of 1-3 Newton applied to the top of the die, top of the substrate and side of the substrate. The highest maximum stress was analyzed and the maximum equivalent stress was observed on the solder ball and the die. From the simulation result, the CBGA package with less solder balls experience higher stress compared to the package with many solder balls. Therefore, less number of solder ball on the CBGA package results higher stress and critically affect the reliability of the solder balls itself, substrate and die which can lead to the solder crack and also die crack.

  4. Supersymmetric Q-balls theory and cosmology

    CERN Document Server

    Kusenko, A

    1999-01-01

    MSSM predicts the existence of Q-balls, some of which can be entirely stable. Both stable and unstable Q-balls can play an important role in cosmology. In particular, Affleck-Dine baryogenesis can result in a copious production of stable baryonic Q-balls, which can presently exist as a form of dark matter.

  5. Associations Between Collateral Status and Thrombus Characteristics and Their Impact in Anterior Circulation Stroke.

    Science.gov (United States)

    Alves, Heitor C; Treurniet, Kilian M; Dutra, Bruna G; Jansen, Ivo G H; Boers, Anna M M; Santos, Emilie M M; Berkhemer, Olvert A; Dippel, Diederik W J; van der Lugt, Aad; van Zwam, Wim H; van Oostenbrugge, Robert J; Lingsma, Hester F; Roos, Yvo B W E M; Yoo, Albert J; Marquering, Henk A; Majoie, Charles B L M

    2018-02-01

    Thrombus characteristics and collateral score are associated with functional outcome in patients with acute ischemic stroke. It has been suggested that they affect each other. The aim of this study is to evaluate the association between clot burden score, thrombus perviousness, and collateral score and to determine whether collateral score influences the association of thrombus characteristics with functional outcome. Patients with baseline thin-slice noncontrast computed tomography and computed tomographic angiography images from the MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands) were included (n=195). Collateral score and clot burden scores were determined on baseline computed tomographic angiography. Thrombus attenuation increase was determined by comparing thrombus density on noncontrast computed tomography and computed tomographic angiography using a semiautomated method. The association of collateral score with clot burden score and thrombus attenuation increase was evaluated with linear regression. Mediation and effect modification analyses were used to assess the influence of collateral score on the association of clot burden score and thrombus attenuation increase with functional outcome. A higher clot burden score (B=0.063; 95% confidence interval, 0.008-0.118) and a higher thrombus attenuation increase (B=0.014; 95% confidence interval, 0.003-0.026) were associated with higher collateral score. Collateral score mediated the association of clot burden score with functional outcome. The association between thrombus attenuation increase and functional outcome was modified by the collateral score, and this association was stronger in patients with moderate and good collaterals. Patients with lower thrombus burden and higher thrombus perviousness scores had higher collateral score. The positive effect of thrombus perviousness on clinical outcome was only present in patients with

  6. Recent Inferior Myocardial Infarction Complicated with a Right Ventricular Thrombus Detected by Three Cardiac Imaging Modalities.

    Science.gov (United States)

    Kuno, Toshiki; Imaeda, Syohei; Hashimoto, Kenji; Ryuzaki, Toshinobu; Saito, Tetsuya; Yamazaki, Hiroyuki; Tabei, Ryota; Kodaira, Masaki; Hase, Manabu; Numasawa, Yohei

    2018-03-01

    We report the case of a 71-year-old woman diagnosed with recent inferior myocardial infarction complicated with right ventricular infarction and a right ventricular thrombus. Three-dimensional transthoracic echocardiography, contrast-enhanced computed tomography, and cardiac magnetic resonance imaging clearly detected a thrombus. We consider cases with a recent right ventricular infarction to require assessment for thrombus formations in the right ventricle. Fortunately, vigorous anticoagulation therapy resolved the thrombi in both the right ventricle and right coronary artery.

  7. Angioplasty of symptomatic high-grade internal carotid artery stenosis with intraluminal thrombus: therapeutic approach

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, A.; Mayol, A. [Seccion de Neurorradiologia Intervencionista, Servicio de Radiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Gil-Peralta, A.; Gonzalez-Marcos, J.R. [Servicio de Neurologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Boza, F. [Servicio de Neurofisiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Ruano, J. [Unidad de Cuidados Intensivos, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain)

    2004-04-01

    Intraluminal thrombus in the internal carotid artery (ICA) is usually found in patients with severe atheromatous stenosis. Having reviewed 300 carotid angioplasties for symptomatic >70% ICA stenosis, we found three patients (1%) with intraluminal thrombus. Conservative treatment with anticoagulants and double antiplatelet coverage can result in lysis of the thrombus without severe risks. Percutaneous transluminal angioplasty and stenting, preferably with distal protection, can be an excellent alternative to carotid endarterectomy. (orig.)

  8. Computational Study of Thrombus Formation and Clotting Factor Effects under Venous Flow Conditions

    Science.gov (United States)

    2016-04-26

    domain used in our thrombus formation simulations. Fig. 2 B shows the 3D geometry of the flow-chamber section consisting of two channels measuring 250 60...ArticleComputational Study of Thrombus Formation and Clotting Factor Effects under Venous Flow ConditionsVijay Govindarajan,1 Vineet Rakesh,1 Jaques...understanding of thrombus formation as a physicochemical process that has evolved to protect the integrity of the human vasculature is critical to our ability to

  9. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Santos, Emilie M.M.; Yoo, Albert J.; Beenen, Ludo F.; Majoie, Charles B.; Berkhemer, Olvert A.; Blanken, Mark D. den; Wismans, Carrie; Niessen, Wiro J.; Marquering, Henk A.

    2016-01-01

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  10. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Emilie M.M. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Department of Radiology, AMC, Amsterdam (Netherlands); Yoo, Albert J. [Texas Stroke Institute, Plano, TX (United States); Beenen, Ludo F.; Majoie, Charles B. [Department of Radiology, AMC, Amsterdam (Netherlands); Berkhemer, Olvert A. [Department of Radiology, AMC, Amsterdam (Netherlands); Department of Neurology, Erasmus MC, Rotterdam (Netherlands); Blanken, Mark D. den; Wismans, Carrie [AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Niessen, Wiro J. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Marquering, Henk A. [Department of Radiology, AMC, Amsterdam (Netherlands); AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Collaboration: on behalf of the MR CLEAN investigators

    2016-02-15

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  11. Thrombus length discrepancy on dual-phase CT can predict clinical outcome in acute ischemic stroke

    International Nuclear Information System (INIS)

    Park, Mina; Kim, Kyung-eun; Lee, Seung-Koo; Shin, Na-Young; Lim, Soo Mee; Song, Dongbeom; Heo, Ji Hoe; Kim, Jin Woo; Oh, Se Won

    2016-01-01

    The thrombus length may be overestimated on early arterial computed tomography angiography (CTA) depending on the collateral status. We evaluated the value of a grading system based on the thrombus length discrepancy on dual-phase CT in outcome prediction. Forty-eight acute ischemic stroke patients with M1 occlusion were included. Dual-phase CT protocol encompassed non-contrast enhanced CT, CTA with a bolus tracking technique, and delayed contrast enhanced CT (CECT) performed 40s after contrast injection. The thrombus length discrepancy between CTA and CECT was graded by using a three-point scale: G0 = no difference; G1 = no difference in thrombus length, but in attenuation distal to thrombus; G2 = difference in thrombus length. Univariate and multivariate analyses were performed to define independent predictors of poor clinical outcome at 3 months. The thrombus discrepancy grade showed significant linear relationships with both the collateral status (P = 0.008) and the presence of antegrade flow on DSA (P = 0.010) with good interobserver agreement (κ = 0.868). In a multivariate model, the presence of thrombus length discrepancy (G2) was an independent predictor of poor clinical outcome [odds ratio = 11.474 (1.350-97.547); P =0.025]. The presence of thrombus length discrepancy on dual-phase CT may be a useful predictor of unfavourable clinical outcome in acute M1 occlusion patients. (orig.)

  12. Ball mounting fixture for a roundness gage

    Science.gov (United States)

    Gauler, Allen L.; Pasieka, Donald F.

    1983-01-01

    A ball mounting fixture for a roundness gage is disclosed. The fixture includes a pair of chuck assemblies oriented substantially transversely with respect to one another and mounted on a common base. Each chuck assembly preferably includes a rotary stage and a wobble plate affixed thereto. A ball chuck affixed to each wobble plate is operable to selectively support a ball to be measured for roundness, with the wobble plate permitting the ball chuck to be tilted to center the ball on the axis of rotation of the rotary stage. In a preferred embodiment, each chuck assembly includes a vacuum chuck operable to selectively support the ball to be measured for roundness. The mounting fixture enables a series of roundness measurements to be taken with a conventional rotating gagehead roundness instrument, which measurements can be utilized to determine the sphericity of the ball.

  13. Ceramic Rail-Race Ball Bearings

    Science.gov (United States)

    Balzer, Mark A.; Mungas, Greg S.; Peters, Gregory H.

    2010-01-01

    Non-lubricated ball bearings featuring rail races have been proposed for use in mechanisms that are required to function in the presence of mineral dust particles in very low-pressure, dry environments with extended life. Like a conventional ball bearing, the proposed bearing would include an inner and an outer ring separated by balls in rolling contact with the races. However, unlike a conventional ball bearing, the balls would not roll in semi-circular or gothic arch race grooves in the rings: instead, the races would be shaped to form two or more rails (see figure). During operation, the motion of the balls would push dust particles into the spaces between the rails where the particles could not generate rolling resistance for the balls

  14. Enhanced venous thrombus resolution in plasminogen activator inhibitor type-2 deficient mice.

    Science.gov (United States)

    Siefert, S A; Chabasse, C; Mukhopadhyay, S; Hoofnagle, M H; Strickland, D K; Sarkar, R; Antalis, T M

    2014-10-01

    The resolution of deep vein thrombosis requires an inflammatory response and mobilization of proteases, such as urokinase-type plasminogen activator (uPA) and matrix metalloproteinases (MMPs), to degrade the thrombus and remodel the injured vein wall. Plasminogen activator inhibitor type 2 (PAI-2) is a serine protease inhibitor (serpin) with unique immunosuppressive and cell survival properties that was originally identified as an inhibitor of uPA. To investigate the role of PAI-2 in venous thrombus formation and resolution. Venous thrombus resolution was compared in wild-type C57BL/6, PAI-2(-/-) , and PAI-1(-/-) mice using the stasis model of deep vein thrombosis. Formed thrombi were harvested, thrombus weights were recorded, and tissue was analyzed for uPA and MMP activities, PAI-1 expression, and the nature of inflammatory cell infiltration. We found that the absence of PAI-2 enhanced venous thrombus resolution, while thrombus formation was unaffected. Enhanced venous thrombus resolution in PAI-2(-/-) mice was associated with increased uPA activity and reduced levels of PAI-1, with no significant effect on MMP-2 and -9 activities. PAI-1 deficiency resulted in an increase in thrombus resolution similar to PAI-2 deficiency, but additionally reduced venous thrombus formation and altered MMP activity. PAI-2-deficient thrombi had increased levels of the neutrophil chemoattractant CXCL2, which was associated with early enhanced neutrophil recruitment. These data identify PAI-2 as a novel regulator of venous thrombus resolution, which modulates several pathways involving both inflammatory and uPA activity mechanisms, distinct from PAI-1. Further examination of these pathways may lead to potential therapeutic prospects in accelerating thrombus resolution. © 2014 International Society on Thrombosis and Haemostasis.

  15. Matrix Metalloproteinase 9 (MMP-9 Regulates Vein Wall Biomechanics in Murine Thrombus Resolution.

    Directory of Open Access Journals (Sweden)

    Khanh P Nguyen

    Full Text Available Deep venous thrombosis is a common vascular problem with long-term complications including post-thrombotic syndrome. Post-thrombotic syndrome consists of leg pain, swelling and ulceration that is related to incomplete or maladaptive resolution of the venous thrombus as well as loss of compliance of the vein wall. We examine the role of metalloproteinase-9 (MMP-9, a gene important in extracellular remodeling in other vascular diseases, in mediating thrombus resolution and biomechanical changes of the vein wall.The effects of targeted deletion of MMP-9 were studied in an in vivo murine model of thrombus resolution using the FVB strain of mice. MMP-9 expression and activity significantly increased on day 3 after DVT. The lack of MMP-9 impaired thrombus resolution by 27% and this phenotype was rescued by the transplantation of wildtype bone marrow cells. Using novel biomechanical techniques, we demonstrated that the lack of MMP-9 significantly decreased thrombus-induced loss of vein wall compliance. Biomechanical analysis of the contribution of individual structural components showed that MMP-9 affected the elasticity of the extracellular matrix and collagen-elastin fibers. Biochemical and histological analyses correlated with these biomechanical effects as thrombi of mice lacking MMP-9 had significantly fewer macrophages and collagen as compared to those of wildtype mice.MMP-9 mediates thrombus-induced loss of vein wall compliance by increasing stiffness of the extracellular matrix and collagen-elastin fibers during thrombus resolution. MMP-9 also mediates macrophage and collagen content of the resolving thrombus and bone-marrow derived MMP-9 plays a role in resolution of thrombus mass. These disparate effects of MMP-9 on various aspects of thrombus illustrate the complexity of individual protease function on biomechanical and morphometric aspects of thrombus resolution.

  16. Matrix Metalloproteinase 9 (MMP-9) Regulates Vein Wall Biomechanics in Murine Thrombus Resolution

    Science.gov (United States)

    Nguyen, Khanh P.; McGilvray, Kirk C.; Puttlitz, Christian M.; Mukhopadhyay, Subhradip; Chabasse, Christine; Sarkar, Rajabrata

    2015-01-01

    Objective Deep venous thrombosis is a common vascular problem with long-term complications including post-thrombotic syndrome. Post-thrombotic syndrome consists of leg pain, swelling and ulceration that is related to incomplete or maladaptive resolution of the venous thrombus as well as loss of compliance of the vein wall. We examine the role of metalloproteinase-9 (MMP-9), a gene important in extracellular remodeling in other vascular diseases, in mediating thrombus resolution and biomechanical changes of the vein wall. Methods and Results The effects of targeted deletion of MMP-9 were studied in an in vivo murine model of thrombus resolution using the FVB strain of mice. MMP-9 expression and activity significantly increased on day 3 after DVT. The lack of MMP-9 impaired thrombus resolution by 27% and this phenotype was rescued by the transplantation of wildtype bone marrow cells. Using novel biomechanical techniques, we demonstrated that the lack of MMP-9 significantly decreased thrombus-induced loss of vein wall compliance. Biomechanical analysis of the contribution of individual structural components showed that MMP-9 affected the elasticity of the extracellular matrix and collagen-elastin fibers. Biochemical and histological analyses correlated with these biomechanical effects as thrombi of mice lacking MMP-9 had significantly fewer macrophages and collagen as compared to those of wildtype mice. Conclusions MMP-9 mediates thrombus-induced loss of vein wall compliance by increasing stiffness of the extracellular matrix and collagen-elastin fibers during thrombus resolution. MMP-9 also mediates macrophage and collagen content of the resolving thrombus and bone-marrow derived MMP-9 plays a role in resolution of thrombus mass. These disparate effects of MMP-9 on various aspects of thrombus illustrate the complexity of individual protease function on biomechanical and morphometric aspects of thrombus resolution. PMID:26406902

  17. Portal Vein Tumor Thrombus of Liver Metastasis from Lung Cancer

    Directory of Open Access Journals (Sweden)

    Ryoko Ogawa

    2009-01-01

    Full Text Available We report a case of liver metastasis of lung carcinoma with portal vein tumor thrombus (PVTT. Although the primary lesion of lung tumor remained unchanged, the patient rapidly developed wide-spread metastases and formed PVTT of liver metastasis. The primary lesion showed features of mixed Clara and bronchial surface epithelial cell component type adenocarcinoma with small foci of micropapillary pattern. Micropapillary pattern was observed in the metastatic lesions in the liver and PVTT. Micropapillary pattern lung adenocarcinoma may develop rapid metastases and cause PVTT associated with liver metastasis. We should perform a detailed examination to establish correct diagnosis.

  18. Variable effects of radiological contrast media on thrombus growth in a rabbit jugular vein thrombosis model

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; Biemond, B. J.; Sturk, A.; Hoek, J.; ten Cate, J. W.

    1991-01-01

    We studied the effect of an ionic high osmolar contrast medium (Ioxitalamate), an ionic low osmolar contrast medium (Ioxaglate) and various nonionic low osmolar contrast media (Iopamidol, Iopromide and Iohexol) on thrombus growth in a rabbit jugular vein thrombosis model. Thrombus growth was

  19. Deep vein thrombus formation induced by flow reduction in mice is determined by venous side branches.

    Science.gov (United States)

    Brandt, Moritz; Schönfelder, Tanja; Schwenk, Melanie; Becker, Christian; Jäckel, Sven; Reinhardt, Christoph; Stark, Konstantin; Massberg, Steffen; Münzel, Thomas; von Brühl, Marie-Luise; Wenzel, Philip

    2014-01-01

    Interaction between vascular wall abnormalities, inflammatory leukocytes, platelets, coagulation factors and hemorheology in the pathogenesis of deep vein thrombosis (DVT) is incompletely understood, requiring well defined animal models of human disease. We subjected male C57BL/6 mice to ligation of the inferior vena cava (IVC) as a flow reduction model to induce DVT. Thrombus size and weight were analyzed macroscopically and sonographically by B-mode, pulse wave (pw) Doppler and power Doppler imaging (PDI) using high frequency ultrasound. Thrombus size varied substantially between individual procedures and mice, irrespective of the flow reduction achieved by the ligature. Interestingly, PDI accurately predicted thrombus size in a very robust fashion (r2 = 0.9734, p thrombus weight (r2 = 0.5597, p thrombus formation. Occlusion of side branches prior to ligation of IVC did not increase thrombus size, probably due to patent side branches inaccessible to surgery. Venous side branches influence thrombus size in experimental DVT and might therefore prevent thrombus formation. This renders vessel anatomy and hemorheology important determinants in mouse models of DVT, which should be controlled for.

  20. Successful catheter directed thrombolysis of IVC and renal vein occlusive thrombus.

    LENUS (Irish Health Repository)

    McCarthy, E

    2011-11-01

    Thrombus formation is a recognised complication of IVC filter placement, however IVC and bilateral renal vein occlusion secondary to thrombus is much less common. We present a case of infrahepatic caval and bilateral renal vein occlusion secondary to thrombosis of a suprarenal IVC filter. With progressive clinical deterioration and failure of conservative medical management the patient underwent successful mechanical disruption and catheter directed thrombolysis.

  1. Successful Treatment of Free-Floating Right Ventricular Thrombus with Acute Pulmonary Embolism

    Directory of Open Access Journals (Sweden)

    Sanjay Singhal

    2015-01-01

    Full Text Available Acute pulmonary embolism with floating right intra-ventricular thrombus is a rare phenomena associated with poor prognosis. Here, we are presenting a case of 35-year-young male with no co-morbid illness diagnosed to have right ventricular thrombus with bilateral pulmonary embolism, which was managed successfully with thrombolytic therapy.

  2. Ball Screw Actuator Including a Stop with an Integral Guide

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Perek, John (Inventor); Geck, Kellan (Inventor)

    2015-01-01

    An actuator includes a housing assembly, a ball nut, a ball screw, and a ball screw stop. The ball nut is rotationally mounted in the housing assembly, is adapted to receive an input torque, and is configured, upon receipt thereof, to rotate and supply a drive force. The ball screw is mounted within the housing assembly and extends through the ball nut. The ball screw has a first end and a second end, and is coupled to receive the drive force from the ball nut. The ball screw is configured, upon receipt of the drive force, to selectively translate between a stow position and a deploy position. The ball screw stop is mounted on the ball screw to translate therewith and is configured to at selectively engage the housing assembly while the ball screw is translating, and engage the ball nut when the ball screw is in the deploy position.

  3. Fibrin d-dimer concentration, deep vein thrombosis symptom duration, and venous thrombus volume.

    Science.gov (United States)

    Kurklinsky, Andrew K; Kalsi, Henna; Wysokinski, Waldemar E; Mauck, Karen F; Bhagra, Anjali; Havyer, Rachel D; Thompson, Carrie A; Hayes, Sharonne N; McBane, Robert D

    2011-04-01

    To determine the relationship between fibrin D-dimer levels, symptom duration, and thrombus volume, consecutive patients with incident deep venous thrombosis (DVT) were evaluated. In a cross-sectional study design, patient symptom onset was determined by careful patient questioning. Venous thrombosis was confirmed by compression duplex ultrasonography. Thrombus volume was estimated based on patient's femur length using a forensic anthropology method. Fibrin D-dimer was measured by latex immunoassay. 72 consecutive patients with confirmed leg DVT agreed to participate. The median symptom duration at the time of diagnosis was 10 days. The median D-dimer concentration was 1050 ng/dL. The median thrombus volume was 12.92 cm(3). D-Dimer levels correlated with estimated thrombus volume (P venous thrombosis and correlates with thrombus volume.

  4. Tumor thrombus formation in two dogs with insulinomas.

    Science.gov (United States)

    Hambrook, Lydia E; Kudnig, Simon T

    2012-10-15

    A 9-year-old sexually intact male Staffordshire Bull Terrier and a 9-year-old neutered male Boxer were evaluated for intermittent neurologic signs including muscle tremors, ataxia, episodic collapse, disorientation, and seizures. Both dogs had low blood glucose and high serum insulin concentrations. Results of abdominal ultrasonography were unremarkable for both dogs. Exploratory laparotomy revealed a mass that extended from the body of the pancreas into the pancreaticoduodenal vein in each dog. Marginal resection of pancreatic masses was performed, and tumor thrombi were removed via venotomy in both dogs. Histologic evaluation indicated the masses were pancreatic islet cell tumors with tumor thrombi. Clinical signs resolved following surgical resection of tumors and tumor thrombi, and the dogs were euglycemic during the follow-up period (17 and 45 months after surgery). Although gross tumor thrombus formation has been identified in humans with insulinomas, tumor thrombi have not been previously reported for dogs with insulinomas. Surgical removal of tumor thrombi via venotomy seemed to be well tolerated by the dogs. Tumor thrombus formation did not seem to adversely affect prognosis for the 2 dogs of this report.

  5. Imaging thrombus with radiolabelled monoclonal antibody to platelets

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Lavender, J.P.; Needham, S.G.; Loutfi, I.; Snook, D.; Epenetos, A.A.; Lumley, P.; Keery, R.J.; Hogg, N.

    1986-12-13

    A study was conducted evaluating a method of imaging thrombus with platelets radiolabelled with a /sup 111/In labelled monoclonal antibody, P256, directed to the platelet surface glycoprotein complex IIb/IIIa. when the number of receptors occupied by P256 was less than 3% of the total available on the platelet surface, platelet function was undisturbed. P256 was radiolabelled with /sup 111/In using diethylenetriaminepenta-acetic acid, which achieved a specific activity of 185 MBq (5 mCi)/mg. No impairment of immunoreactivity was detected at this specific activity. Platelets were labelled with radiolabelled monoclonal antibody in vitro in two patients at a receptor occupancy of 6% and in vivo in six patients at a receptor occupancy of 1%. In vivo recovery and biodistribution kinetics suggested that after in vitro labelling platelets were minimally activated. The /sup 111/In kinetics recorded after intravenous P256 suggested rapid and efficient radiolabelling of platelets and gave no indication of platelet activation. Of the six patients who received intravenous P256, three had documented thrombus, two of whom gave positive results on P256 platelet scintigraphy. The third had chronic deep venous thrombosis and was scintigraphically negative.

  6. Intracardiac thrombus in Behçet’s disease

    Directory of Open Access Journals (Sweden)

    I. Ben Ghorbel

    2016-12-01

    Full Text Available Behçet’s disease (BD is a multisystem inflammatory disorder. Intracardiac thrombus (ICT formation is an uncommon but important complication of BD. Of the cases of Behçet’s disease, we selected those with ICT. All patients fulfilled the diagnostic criteria of the International Study Group of Behçet’s disease. The ICT in each case was confirmed by ultrasonography, computed tomography and MRI. Clinical features and laboratory parameters were determined. Among our 518 patients with BD, 8 were diagnosed as having intracardiac thrombus (ICT. All were male; the mean age at the time of the ICT diagnosis was 30.8 years. The main presenting symptoms were hemoptysis, chest pain, and dyspnea. It was associated with pulmonary artery aneurysm and vena cava thrombosis in 3 cases each, pulmonary embolism, and lower limbs deep venous thrombosis in 1 case each. The coexistence of other cardiac complications was as follows: pericarditis in 2 cases, myocarditis, endomyocardial fibrosis, and coronary arteritis with consequent myocardial infarction in one case each. In all cases, echocardiography was sufficient to reach the diagnosis. Chest computed tomography performed in all cases led to the diagnosis of associated pulmonary vasculo-Behçet lesions in 4 cases. All patients received colchicine, anticoagulation, and corticosteroids. Seven patients were on immunosuppressant agents (2 patients received azathioprine and 5 cyclophosphamide. Clinical remission with ICT resolution was observed in 5 cases. Combined immunosuppressive therapy with prednisone and cyclophosphamide might be needed to treat ICT due to BD.

  7. Apparatus Would Measure Temperatures Of Ball Bearings

    Science.gov (United States)

    Gibson, John C.; Fredricks, Thomas H.

    1995-01-01

    Rig for testing ball bearings under radial and axial loads and measuring surface temperatures undergoing development. Includes extensible thermocouples: by means of bellows as longitudinal positioners, thermocouples driven into contact with bearing balls to sense temperatures immediately after test run. Not necessary to disassemble rig or to section balls to obtain indirect indications of maximum temperatures reached. Thermocouple measurements indicate temperatures better than temperature-sensitive paints.

  8. Multifractal properties of ball milling dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Budroni, M. A., E-mail: mabudroni@uniss.it; Pilosu, V.; Rustici, M. [Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, Sassari 07100 (Italy); Delogu, F. [Dipartimento di Ingegneria Meccanica, Chimica, e dei Materiali, Università degli Studi di Cagliari, via Marengo 2, Cagliari 09123 (Italy)

    2014-06-15

    This work focuses on the dynamics of a ball inside the reactor of a ball mill. We show that the distribution of collisions at the reactor walls exhibits multifractal properties in a wide region of the parameter space defining the geometrical characteristics of the reactor and the collision elasticity. This feature points to the presence of restricted self-organized zones of the reactor walls where the ball preferentially collides and the mechanical energy is mainly dissipated.

  9. Physical applications of homogeneous balls

    CERN Document Server

    Scarr, Tzvi

    2005-01-01

    One of the mathematical challenges of modern physics lies in the development of new tools to efficiently describe different branches of physics within one mathematical framework. This text introduces precisely such a broad mathematical model, one that gives a clear geometric expression of the symmetry of physical laws and is entirely determined by that symmetry. The first three chapters discuss the occurrence of bounded symmetric domains (BSDs) or homogeneous balls and their algebraic structure in physics. The book further provides a discussion of how to obtain a triple algebraic structure ass

  10. The Soccer-Ball Problem

    Science.gov (United States)

    Hossenfelder, Sabine

    2014-07-01

    The idea that Lorentz-symmetry in momentum space could be modified but still remain observer-independent has received quite some attention in the recent years. This modified Lorentz-symmetry, which has been argued to arise in Loop Quantum Gravity, is being used as a phenomenological model to test possibly observable effects of quantum gravity. The most pressing problem in these models is the treatment of multi-particle states, known as the 'soccer-ball problem'. This article briefly reviews the problem and the status of existing solution attempts.

  11. Crystal ball data acquisition system

    International Nuclear Information System (INIS)

    Chestnut, R.; Kiesling, C.; Bloom, E.; Bulos, F.; Gaiser, J.; Godfrey, G.; Oreglia, M.; Partridge, R.; Peck, C.; Porter, F.; Aschman, D.; Cavali-Sforza, M.; Coyne, D.; Sadrozinski, H.; Kollmann, W.; Richardson, M.

    1979-01-01

    The data acquisition system for the Crystal Ball project at SLAC is described. A PDP-11/t55 using RSX-11M connected to the SLAC Triplex is the basis of the system. A ''physics pipeline'' allows physicists to write their own equipment-monitoring or physics tasks which require event sampling. As well, an interactive analysis package (MULTI) is in the pipeline. Histogram collection and display on the PDP are implemented using the Triplex histogramming package. Various interactive event displays are also implemented

  12. Ball Nut Preload Diagnosis of the Hollow Ball Screw through Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Yi-Cheng Huang

    2018-01-01

    Full Text Available This paper studies the diagnostic results of hollow ball screws with different ball nut preload through the support vector machine (SVM process. The method is testified by considering the use of ball screw pretension and different ball nut preload. SVM was used to discriminate the hollow ball screw preload status through the vibration signals and servo motor current signals. Maximum dynamic preloads of 2%, 4%, and 6% ball screws were predesigned, manufactured, and conducted experimentally. Signal patterns with different preload features are separatedby SVM. The irregularity development of the ball screw driving motion current and rolling balls vibration of the ball screw can be discriminated via SVM based on complexity perception. The experimental results successfully show that the prognostic status of ball nut preload can be envisaged by the proposed methodology. The smart reasoning for the health of the ball screw is available based on classification of SVM. This diagnostic method satisfies the purposes of prognostic effectiveness on knowing the ball nut preload status

  13. The imaging features of neurologic complications of left atrial myxomas

    International Nuclear Information System (INIS)

    Liao, Wei-Hua; Ramkalawan, Divya; Liu, Jian-Ling; Shi, Wei; Zee, Chi-Shing; Yang, Xiao-Su; Li, Guo-Liang; Li, Jing; Wang, Xiao-Yi

    2015-01-01

    Background: Neurologic complications may be the first symptoms of atrial myxomas. Understanding the imaging features of neurologic complications of atrial myxomas can be helpful for the prompt diagnosis. Objective: To identify neuroimaging features for patients with neurologic complications attributed to atrial myxoma. Methods: We retrospectively reviewed the medical records of 103 patients with pathologically confirmed atrial myxoma at Xiangya Hospital from January 2009 to January 2014. The neuroimaging data for patients with neurologic complications were analyzed. Results: Eight patients with atrial myxomas (7.77%) presented with neurologic manifestations, which constituted the initial symptoms for seven patients (87.5%). Neuroimaging showed five cases of cerebral infarctions and three cases of aneurysms. The main patterns of the infarctions were multiplicity (100.0%) and involvement of the middle cerebral artery territory (80.0%). The aneurysms were fusiform in shape, multiple in number (100.0%) and located in the distal middle cerebral artery (100.0%). More specifically, high-density in the vicinity of the aneurysms was observed on CT for two patients (66.7%), and homogenous enhancement surrounding the aneurysms was detected in the enhanced imaging for two patients (66.7%). Conclusion: Neurologic complications secondary to atrial myxoma consist of cerebral infarctions and aneurysms, which show certain characteristic features in neuroimaging. Echocardiography should be performed in patients with multiple cerebral infarctions, and multiple aneurysms, especially when aneurysms are distal in location. More importantly, greater attention should be paid to the imaging changes surrounding the aneurysms when myxomatous aneurysms are suspected and these are going to be the relevant features in our article

  14. Left atrial leiomyosarcoma as cause of heart failure

    International Nuclear Information System (INIS)

    Valdes Martin, Alexander

    2012-01-01

    The case of a 26 year-old patient with diagnosis of heart failure and presence of a mobile echogenic mass without calcification attached to the posterolateral area of the left atrium was reported. She underwent surgery and tissue examination evidenced a high-grade heart leiomyosarcoma. Postoperative course was satisfactory and her clinical state was rigorously monitored by oncology and heart specialists in the institution

  15. The imaging features of neurologic complications of left atrial myxomas

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Wei-Hua; Ramkalawan, Divya; Liu, Jian-Ling; Shi, Wei [Department of Radiology, Xiangya Hospital, Central South University, Changsha 410008, Hunan (China); Zee, Chi-Shing [Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033 (United States); Yang, Xiao-Su; Li, Guo-Liang; Li, Jing [Department of Neurology, Xiangya Hospital, Central South University, Changsha 410008, Hunan (China); Wang, Xiao-Yi, E-mail: cjr.wangxiaoyi@vip.163.com [Department of Radiology, Xiangya Hospital, Central South University, Changsha 410008, Hunan (China)

    2015-05-15

    Background: Neurologic complications may be the first symptoms of atrial myxomas. Understanding the imaging features of neurologic complications of atrial myxomas can be helpful for the prompt diagnosis. Objective: To identify neuroimaging features for patients with neurologic complications attributed to atrial myxoma. Methods: We retrospectively reviewed the medical records of 103 patients with pathologically confirmed atrial myxoma at Xiangya Hospital from January 2009 to January 2014. The neuroimaging data for patients with neurologic complications were analyzed. Results: Eight patients with atrial myxomas (7.77%) presented with neurologic manifestations, which constituted the initial symptoms for seven patients (87.5%). Neuroimaging showed five cases of cerebral infarctions and three cases of aneurysms. The main patterns of the infarctions were multiplicity (100.0%) and involvement of the middle cerebral artery territory (80.0%). The aneurysms were fusiform in shape, multiple in number (100.0%) and located in the distal middle cerebral artery (100.0%). More specifically, high-density in the vicinity of the aneurysms was observed on CT for two patients (66.7%), and homogenous enhancement surrounding the aneurysms was detected in the enhanced imaging for two patients (66.7%). Conclusion: Neurologic complications secondary to atrial myxoma consist of cerebral infarctions and aneurysms, which show certain characteristic features in neuroimaging. Echocardiography should be performed in patients with multiple cerebral infarctions, and multiple aneurysms, especially when aneurysms are distal in location. More importantly, greater attention should be paid to the imaging changes surrounding the aneurysms when myxomatous aneurysms are suspected and these are going to be the relevant features in our article.

  16. Left atrial appendage occlusion with the AMPLATZER Amulet device

    DEFF Research Database (Denmark)

    Tzikas, Apostolos; Gafoor, Sameer; Meerkin, David

    2016-01-01

    is proposed. Device preparation and de-airing is briefly described, followed by sheath exchange, device deployment steps, evaluation of device stability and decision for final release. The way to recapture and change a device is then shown, together with some additional tips on how to deal with challenging...... and had personal clinical experience with the AMPLATZER Amulet device were asked to contribute in the preparation of this consensus document. Twenty-seven physicians (20 interventional cardiologists and 7 electrophysiologists) from 14 different countries reviewed the manuscript. A step-by-step approach...

  17. Unusual case of left atrial myxoma with gastroesophageal junction adenocarcinoma.

    Science.gov (United States)

    Singh, Narinder Pal; Nagpal, Swapan Deep Singh; Goel, Arun Kumar; Dhingra, Bhupendra Kr

    2018-02-01

    Cardiac myxomas are rare tumors. Esophageal adenocarcinomas are common tumors of the gastrointestinal tract. Simultaneous occurrence of these tumors has not been reported. A 52-year-old gentleman presented to our hospital with dysphagia and was diagnosed with esophageal adenocarcinoma. Routine echocardiography discovered a cardiac tumor in the left atrium. The cardiac tumor was surgically removed and biopsy confirmed a myxoma. We removed the cardiac tumor as the first step and then initiated neoadjuvant chemotherapy. It is ideal to constitute a multidisciplinary team to decide on the course of treatment in such cases.

  18. LEFT ATRIAL MYXOMA: CASE REPORT AND LITERATURE REVIEW

    African Journals Online (AJOL)

    2011-02-02

    Feb 2, 2011 ... Myxomas are the most common cardiac neoplasm accounting for 50% of all tumours. ... Hanson et al (6) with a 24 year review of 33 patients ... We acknowledge the financial and technical assistance respectively from the Lagos State Government and. Global Eagle Foundation, an American based non-.

  19. Platelet endothelial cell adhesion molecule 1 deficiency misguides venous thrombus resolution.

    Science.gov (United States)

    Kellermair, Joerg; Redwan, Bassam; Alias, Sherin; Jabkowski, Joerg; Panzenboeck, Adelheid; Kellermair, Lukas; Winter, Max P; Weltermann, Ansgar; Lang, Irene M

    2013-11-07

    Platelet endothelial cell adhesion molecule 1 (PECAM-1) is involved in leukocyte migration and angiogenesis, which are key components of venous thrombus resolution. This study investigated the effect of PECAM-1 deficiency on thrombus resolution in FVB/n mice and the extent to which levels of soluble PECAM-1 (sPECAM-1) correlate with delayed thrombus resolution in humans after acute symptomatic deep vein thrombosis (DVT). In a mouse stagnant flow venous thrombosis model Pecam-1(-/-) thrombi were larger, persisted for longer periods of time, and displayed attenuated macrophage invasion and decreased vessel formation in the presence of increased fibrosis. In humans, higher levels of truncated plasma sPECAM-1 possibly cleaved from cell surfaces, were found in patients with delayed thrombus resolution (assessed via duplex-based thrombus scoring) relative to those whose thrombi resolved (median, 25th/75th percentile): 92.5 (87.7/103.4) ng/mL vs 71.5 (51.1/81.0) ng/mL; P deep vein thrombus specimens stained positively with antibodies specific for the extracellular, but not the cytoplasmic domain of PECAM-1, consistent with accumulation of cleaved PECAM-1. Our data suggest a regulatory role of PECAM-1 in venous thrombus resolution and suggest a predictive value of sPECAM-1 for postthrombotic syndrome (PTS) after acute DVT.

  20. Elevated plasma factor VIII enhances venous thrombus formation in rabbits: contribution of factor XI, von Willebrand factor and tissue factor.

    Science.gov (United States)

    Sugita, Chihiro; Yamashita, Atsushi; Matsuura, Yunosuke; Iwakiri, Takashi; Okuyama, Nozomi; Matsuda, Shuntaro; Matsumoto, Tomoko; Inoue, Osamu; Harada, Aya; Kitazawa, Takehisa; Hattori, Kunihiro; Shima, Midori; Asada, Yujiro

    2013-07-01

    Elevated plasma levels of factor VIII (FVIII) are associated with increased risk of deep venous thrombosis. The aim of this study is to elucidate how elevated FVIII levels affect venous thrombus formation and propagation in vivo. We examined rabbit plasma FVIII activity, plasma thrombin generation, whole blood coagulation, platelet aggregation and venous wall thrombogenicity before and one hour after an intravenous infusion of recombinant human FVIII (rFVIII). Venous thrombus induced by the endothelial denudation of rabbit jugular veins was histologically assessed. Thrombus propagation was evaluated as indocyanine green fluorescence intensity. Argatroban, a thrombin inhibitor, and neutralised antibodies for tissue factor (TF), factor XI (FXI), and von Willebrand factor (VWF) were infused before or after thrombus induction to investigate their effects on venous thrombus formation or propagation. Recombinant FVIII (100 IU/kg) increased rabbit plasma FVIII activity two-fold and significantly enhanced whole blood coagulation and total plasma thrombin generation, but did not affect initial thrombin generation time, platelet aggregation and venous wall thrombogenicity. The rFVIII infusion also increased the size of venous thrombus 1 hour after thrombus induction. Argatroban and the antibodies for TF, FXI or VWF inhibited such enhanced thrombus formation and all except TF suppressed thrombus propagation. In conclusion, elevated plasma FVIII levels enhance venous thrombus formation and propagation. Excess thrombin generation by FXI and VWF-mediated FVIII recruitment appear to contribute to the growth of FVIII-driven venous thrombus.

  1. Left ventricular thrombus formation after acute myocardial infarction as assessed by cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Delewi, Ronak; Nijveldt, Robin; Hirsch, Alexander; Marcu, Constantin B.; Robbers, Lourens; Hassell, Marriela E.C.J.; Bruin, Rianne H.A. de; Vleugels, Jim; Laan, Anja M. van der; Bouma, Berto J.; Tio, René A.; Tijssen, Jan G.P.; Rossum, Albert C. van; Zijlstra, Felix; Piek, Jan J.

    2012-01-01

    Introduction: Left ventricular (LV) thrombus formation is a feared complication of myocardial infarction (MI). We assessed the prevalence of LV thrombus in ST-segment elevated MI patients treated with percutaneous coronary intervention (PCI) and compared the diagnostic accuracy of transthoracic echocardiography (TTE) to cardiovascular magnetic resonance imaging (CMR). Also, we evaluated the course of LV thrombi in the modern era of primary PCI. Methods: 200 patients with primary PCI underwent TTE and CMR, at baseline and at 4 months follow-up. Studies were analyzed by two blinded examiners. Patients were seen at 1, 4, 12, and 24 months for assessment of clinical status and adverse events. Results: On CMR at baseline, a thrombus was found in 17 of 194 (8.8%) patients. LV thrombus resolution occurred in 15 patients. Two patients had persistence of LV thrombus on follow-up CMR. On CMR at four months, a thrombus was found in an additional 12 patients. In multivariate analysis, thrombus formation on baseline CMR was independently associated with, baseline infarct size (g) (B = 0.02, SE = 0.02, p < 0.001). Routine TTE had a sensitivity of 21–24% and a specificity of 95–98% compared to CMR for the detection of LV thrombi. Intra- and interobserver variation for detection of LV thrombus were lower for CMR (κ = 0.91 and κ = 0.96) compared to TTE (κ = 0.74 and κ = 0.53). Conclusion: LV thrombus still occurs in a substantial amount of patients after PCI-treated MI, especially in larger infarct sizes. Routine TTE had a low sensitivity for the detection of LV thrombi and the interobserver variation of TTE was large.

  2. Left ventricular thrombus formation after acute myocardial infarction as assessed by cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Delewi, Ronak [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Interuniversity Cardiology Institute of the Netherlands (Netherlands); Nijveldt, Robin [Department of Cardiology, VU University Medical Center, Amsterdam (Netherlands); Hirsch, Alexander [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Marcu, Constantin B.; Robbers, Lourens [Department of Cardiology, VU University Medical Center, Amsterdam (Netherlands); Hassell, Marriela E.C.J.; Bruin, Rianne H.A. de; Vleugels, Jim; Laan, Anja M. van der; Bouma, Berto J. [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Tio, René A. [Thorax Center, University Medical Center Groningen, Groningen (Netherlands); Tijssen, Jan G.P. [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Rossum, Albert C. van [Department of Cardiology, VU University Medical Center, Amsterdam (Netherlands); Zijlstra, Felix [Thorax Center, Department of Cardiology, Erasmus University Medical Center, Rotterdam (Netherlands); Piek, Jan J., E-mail: j.j.piek@amc.uva.nl [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands)

    2012-12-15

    Introduction: Left ventricular (LV) thrombus formation is a feared complication of myocardial infarction (MI). We assessed the prevalence of LV thrombus in ST-segment elevated MI patients treated with percutaneous coronary intervention (PCI) and compared the diagnostic accuracy of transthoracic echocardiography (TTE) to cardiovascular magnetic resonance imaging (CMR). Also, we evaluated the course of LV thrombi in the modern era of primary PCI. Methods: 200 patients with primary PCI underwent TTE and CMR, at baseline and at 4 months follow-up. Studies were analyzed by two blinded examiners. Patients were seen at 1, 4, 12, and 24 months for assessment of clinical status and adverse events. Results: On CMR at baseline, a thrombus was found in 17 of 194 (8.8%) patients. LV thrombus resolution occurred in 15 patients. Two patients had persistence of LV thrombus on follow-up CMR. On CMR at four months, a thrombus was found in an additional 12 patients. In multivariate analysis, thrombus formation on baseline CMR was independently associated with, baseline infarct size (g) (B = 0.02, SE = 0.02, p < 0.001). Routine TTE had a sensitivity of 21–24% and a specificity of 95–98% compared to CMR for the detection of LV thrombi. Intra- and interobserver variation for detection of LV thrombus were lower for CMR (κ = 0.91 and κ = 0.96) compared to TTE (κ = 0.74 and κ = 0.53). Conclusion: LV thrombus still occurs in a substantial amount of patients after PCI-treated MI, especially in larger infarct sizes. Routine TTE had a low sensitivity for the detection of LV thrombi and the interobserver variation of TTE was large.

  3. Biventricular thrombus in hypereosinophilic syndrome presenting with shortness of breath

    Directory of Open Access Journals (Sweden)

    Abdul Baqi

    2016-06-01

    Full Text Available A 48 years old male presented to clinic with 12 months of low grade fever with shortness of breath which has progressively worsened with no associated weight loss, night sweats or loss of appetite. There was no prior history of chronic illness before the current illness. Laboratory workup revealed a high white blood cell count with predominant eosinophils. Chest X-ray was normal. Transthoracic echocardiography and Cardiac Magnetic Resonance showed biventricular thrombi. On further extensive workup the findings were consistent with hypereosinophilic syndrome. The patient was started on oral steroids, hydroxyurea, imatanib mesylate and oral anticoagulation. The patient responded to the treatment with complete resolution of his symptoms over the course of few months. The repeat Echocardiogram after a year showed normal left ventricular systolic and diastolic function with complete resolution of biventricular thrombi. Keywords: Hypereosinophilic syndrome, Thrombus

  4. Importance of Endogenous Fibrinolysis in Platelet Thrombus Formation.

    Science.gov (United States)

    Gue, Ying X; Gorog, Diana A

    2017-08-25

    The processes of thrombosis and coagulation are finely regulated by endogenous fibrinolysis maintaining healthy equilibrium. When the balance is altered in favour of platelet activation and/or coagulation, or if endogenous fibrinolysis becomes less efficient, pathological thrombosis can occur. Arterial thrombosis remains a major cause of morbidity and mortality in the world despite advances in medical therapies. The role endogenous fibrinolysis in the pathogenesis of arterial thrombosis has gained increasing attention in recent years as it presents novel ways to prevent and treat existing diseases. In this review article, we discuss the role of endogenous fibrinolysis in platelet thrombus formation, methods of measurement of fibrinolytic activity, its role in predicting cardiovascular diseases and clinical outcomes and future directions.

  5. Structural and dynamical properties of Yukawa balls

    International Nuclear Information System (INIS)

    Block, D; Kroll, M; Arp, O; Piel, A; Kaeding, S; Ivanov, Y; Melzer, A; Henning, C; Baumgartner, H; Ludwig, P; Bonitz, M

    2007-01-01

    To study the structural and dynamical properties of finite 3D dust clouds (Yukawa balls) new diagnostic tools have been developed. This contribution describes the progress towards 3D diagnostics for measuring the particle positions. It is shown that these diagnostics are capable of investigating the structural and dynamical properties of Yukawa balls and gaining insight into their basic construction principles

  6. Soccer Ball Lift Coefficients via Trajectory Analysis

    Science.gov (United States)

    Goff, John Eric; Carre, Matt J.

    2010-01-01

    We performed experiments in which a soccer ball was launched from a machine while two high-speed cameras recorded portions of the trajectory. Using the trajectory data and published drag coefficients, we extracted lift coefficients for a soccer ball. We determined lift coefficients for a wide range of spin parameters, including several spin…

  7. Incremental value of contrast echocardiography in the evaluation of a cardiac thrombus.

    Science.gov (United States)

    Po, Jose Ricardo F; Tong, Matthew S; Grove, Erica L; Biederman, Robert W W

    2017-02-01

    A 52-year-old man presented with altered mental status and report of prior complaint of chest pain. On electrocardiography, anterolateral ST-segment elevations with Q-waves in the septal leads were seen. Initial echocardiography images demonstrated a thickened anteroseptum. Further imaging showed the presence of a well-attached laminated apical thrombus. Contrast echocardiography images showed that the thrombus had minimal attachment to the endocardial surface. CT head subsequently showed the presence of acute stroke. The case demonstrates the additional value of contrast echocardiography in the evaluation of cardiac masses despite the certainty in the diagnosis of a thrombus. © 2017, Wiley Periodicals, Inc.

  8. Renal angiomyolipoma with inferior vena caval thrombus in a 32-year-old male

    Directory of Open Access Journals (Sweden)

    Matthew W Christian

    2009-01-01

    Full Text Available Renal angiomyolipoma (AML rarely presents with evidence of extension into the renal vein, inferior vena cava (IVC or atrium. We report a case of a renal AML with a tumor thrombus to the IVC in a 32-year-old male. The patient subsequently underwent a right radical nephrectomy with IVC tumor thrombectomy. To our knowledge, there are four published cases of renal AML presenting with tumor thrombus in males. This case report describes the management of the youngest male ever to develop a renal AML with IVC tumor thrombus.

  9. Right Ventricular Endomyocardial Fibrosis Presenting With Ventricular Tachycardia And Apical Thrombus - An Interesting Presentation

    Directory of Open Access Journals (Sweden)

    Amitesh Aggarwal

    2009-11-01

    Full Text Available Endomyocardial fibrosis is a progressive disease of unknown origin affecting children and young adults. It involves inflow portion of right and/or left ventricle and apex. It may be associated with thrombus. Literature regarding right ventricular endomyocardial fibrosis with thrombus is scarce. Here we report a rare case of right ventricular endomyocardial fibrosis presenting as ventricular tachycardia and echocardiographic evidence of apical thrombus. Interestingly there was no pulmonary involvement or evidence of deep venous thrombosis. This case also underscores the importance of urgent echocardiography in diagnosis of obscure cases of ventricular tachycardia.

  10. Study of soccer ball flight trajectory

    Directory of Open Access Journals (Sweden)

    Javorova Juliana

    2018-01-01

    Full Text Available In this paper the trajectories of a soccer ball for the most important kicks in the football game - a corner kick and a direct free kick are studied. The soccer ball is modelled as an ideal rigid hollow spherical body with six degrees of freedom, which performs a general motion in an immovable air environment with constant parameters. The ball 3D orientation is determined by the three Cardan angles. The aerodynamic forces and moments with which the air environment acts to the ball are taken into account. Two of the most dangerous areas of the football goal are defined. Differential equations which describe the motion of the soccer ball are solved numerically by MatLab-Simulink.

  11. A model for ball lightning

    International Nuclear Information System (INIS)

    Fryberger, D.

    1994-10-01

    A model for ball lightning (BL) is described. It is based upon the vorton model for elementary particles, which exploits the symmetry between electricity and magnetism. The core, or driving engine, of BL in this model is comprised of a vorton-antivorton plasma. The energy of BL, which derives from nucleon decay catalyzed by this plasma, leads, through various mechanisms, to BL luminosity as well as to other BL features. It is argued that this model could also be a suitable explanation for other luminous phenomena, such as the unidentified atmospheric light phenomena seen at Hessdalen. It is predicted that BL and similar atmospheric luminous phenomena should manifest certain features unique to this model, which would be observable with suitable instrumentation

  12. La balle et la plume

    Directory of Open Access Journals (Sweden)

    Peter Marquis

    2012-06-01

    Full Text Available Fin octobre 2008, la nouvelle fit l’effet d’une bombe : Barack Obama, alors candidat à la présidence américaine, demanda à la chaîne câblée Fox News de retarder le début du sixième match de la World Series de base-ball afin de diffuser un spot de campagne. Son adversaire, John McCain, soutenu par le camp républicain et une partie de la population, monta aussitôt au créneau pour dénoncer l’hérésie : s’arroger le droit de perturber cette grande finale du championnat au déroulement immuable reve...

  13. Identification of intraluminal thrombus by ultrasonography in emergency department patients with acute deep venous thrombosis.

    Science.gov (United States)

    Mehta, Ninfa; Schecter, Joshua; Stone, Michael

    2012-05-01

    Traditionally, the diagnosis of deep venous thrombosis (DVT) using duplex ultrasonography (DU) has relied on the absence of venous compressibility. Visualization of an intraluminal thrombus is considered an uncommon finding. The purpose of this study is to determine the frequency of intraluminal thrombus in emergency department (ED) patients diagnosed with acute DVT. Retrospective chart review of adult ED patients with DU examinations demonstrating acute DVT. Patients with chronic DVT or patients in whom DU did not demonstrate DVT were excluded from data analysis. Study reports and ultrasound images were reviewed and analyzed for the presence of intraluminal thrombus. There were 189 patients who met inclusion criteria, of which 160 (85%) were found to have intraluminal thrombus. Intraluminal thrombi are present in the majority of patients in our ED in whom acute DVT is identified by DU. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Novel Percutaneous Radiofrequency Ablation of Portal Vein Tumor Thrombus: Safety and Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Mizandari, Malkhaz [High Technology Medical Center, Tbilisi State Medical University (Georgia); Ao, Guokun [The 309 Hospital of People' s Liberation Army, Department on Oncology (China); Zhang Yaojun; Feng Xi [Imperial College London, Department of Surgery and Cancer (United Kingdom); Shen Qiang [The First Minimally Invasive Department of Eastern Hepatobiliary Surgery Hospital (China); Chen Minshan [Cancer Centre of Sun Yat-Sen University, Department of Hepatobiliary Surgery (China); Lau, Wan Yee [Chinese University of Hong Kong, Department of Surgery, Faculty of Medicine (Hong Kong); Nicholls, Joanna; Jiao Long; Habib, Nagy, E-mail: nagy.habib@imperial.ac.uk [Imperial College London, Department of Surgery and Cancer (United Kingdom)

    2013-02-15

    We report our experience of the safety of partial recanalization of the portal vein using a novel endovascular radiofrequency (RF) catheter for portal vein tumor thrombosis. Six patients with liver cancer and tumor thrombus in the portal vein underwent percutaneous intravascular radiofrequency ablation (RFA) using an endovascular bipolar RF device. A 0.035-inch guidewire was introduced into a tributary of the portal vein and through which a 5G guide catheter was introduced into the main portal vein. After manipulation of the guide catheter over the thrombus under digital subtraction angiography, the endovascular RF device was inserted and activated around the thrombus. There were no observed technique specific complications, such as hemorrhage, vessel perforation, or infection. Post-RFA portography showed partial recanalization of portal vein. RFA of portal vein tumor thrombus in patients with hepatocellular carcinoma is technically feasible and warrants further investigation to assess efficacy compared with current recanalization techniques.

  15. Intracardiac thrombus in Behçet's disease: Two case reports

    Directory of Open Access Journals (Sweden)

    Brahem Radhia

    2005-07-01

    Full Text Available Abstract Intracardiac thrombus in Behçet's disease is an extremely rare manifestation. We report two such cases. A 20-year-old man presented with dyspnoea, cough and haemoptysis. Right heart thrombus associated with pulmonary artery aneurysm and thromboembolism was identified by helical CT and transoesophageal echocardiography. The second case was a 29-year-old male admitted for fever and chest pain. A diagnosis of right atrial thrombosis associated with pulmonary embolism and hyperhomocysteinemia was made. Due to the absence of haemodynamic compromise, medical management consisting of immunosupressive and anticoagulation therapy was adopted which resulted in complete dissolution of the thrombus with dramatic clinical improvement in both cases of clinical status. Conclusion intracardiac thrombus is a rare complication of Behçet's disease. As shown in our patients, medical treatment should be considered as the first line.

  16. The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair

    NARCIS (Netherlands)

    F.M.V. Bastos Gonçalves (Frederico); H.J.M. Verhagen (Hence); K. Chinsakchai (Khamin); J.W. van Keulen (Jasper); M.T. Voûte (Michiel); H.J.A. Zandvoort (Herman); F.L. Moll (Frans); J.A. van Herwaarden (Joost)

    2012-01-01

    textabstractObjective: This study investigated the influence of significant aneurysm neck thrombus in clinical and morphologic outcomes after endovascular aneurysm repair (EVAR). Methods: The patient population was derived from a prospective EVAR database from two university institutions in The

  17. Characterization of an experimental venous thrombus model with MRI, phlebography and histology

    International Nuclear Information System (INIS)

    Schmitz, S.A.; Schiffler, S.; Gust, R.; Winterhalter, S.; Wolf, K.J.; Coupland, S.E.

    2005-01-01

    Introduction: Several magnetic resonance (MR) techniques designed to demonstrate the characteristic signal intensity of blood degeneration products of thrombi have been suggested, but the effect of thrombus organization on the MR display, in particular with regard to its temporal evolution, remains to be determined. It is the purpose of this study to develop a stagnation thrombus model in rabbits and to characterize thrombus at different ages with two (MR) imaging techniques, phlebography and histology. Materials and Methods: Venous stagnation thrombi were induced in the external jugular veins of rabbits using a minimally invasive radiological technique to produce artificial embolic vascular occlusion and hypercoagulability. Twenty-five animals were divided into 5 groups of 5 animals, and each group underwent 1.5 T MR imaging at 1, 3, 5, 7 and 9 days after thrombus induction using a T1-weighted magnetization-prepared rapid gradient-echo sequence (MP-RAGE: TR 10.4 msec, TE 4.0 msec, FA 15 ) and a T2-weighted fast low-angle shot sequence (FLASH: TR 54 msec, TE 18 msec, FA15 ). The thrombus length was measured on the T1-weighted images. Thrombus conspicuity, signal intensity, and heterogeneity on T2* weighted images were described using visual scales. Radiographic venography and histology served as reference methods. Results: Thrombi were successfully induced in all animals. The overall thrombus length decreased from 43±9 (day 1 after induction) to 23±4 mm (day 9). On 3D-reconstructions of the T1-weighted images, the visible portion of the true thrombus length relative to the overall thrombus length was 0.16±0.3 (day 1), 0.24±0.3 (day 3),0.38±0.5 (day 5), 0.06±0.1 (day 7) and 0.00 (day 9). Sixteen of 25 thrombi were detectable with the T2*-weighted technique. The overall thrombus signal intensity decreased with the age of the thrombus from day 1 to day 9. The histological evaluation showed that the rabbit thrombi closely resemble human thrombi morphologically

  18. BALL - biochemical algorithms library 1.3

    Directory of Open Access Journals (Sweden)

    Stöckel Daniel

    2010-10-01

    Full Text Available Abstract Background The Biochemical Algorithms Library (BALL is a comprehensive rapid application development framework for structural bioinformatics. It provides an extensive C++ class library of data structures and algorithms for molecular modeling and structural bioinformatics. Using BALL as a programming toolbox does not only allow to greatly reduce application development times but also helps in ensuring stability and correctness by avoiding the error-prone reimplementation of complex algorithms and replacing them with calls into the library that has been well-tested by a large number of developers. In the ten years since its original publication, BALL has seen a substantial increase in functionality and numerous other improvements. Results Here, we discuss BALL's current functionality and highlight the key additions and improvements: support for additional file formats, molecular edit-functionality, new molecular mechanics force fields, novel energy minimization techniques, docking algorithms, and support for cheminformatics. Conclusions BALL is available for all major operating systems, including Linux, Windows, and MacOS X. It is available free of charge under the Lesser GNU Public License (LPGL. Parts of the code are distributed under the GNU Public License (GPL. BALL is available as source code and binary packages from the project web site at http://www.ball-project.org. Recently, it has been accepted into the debian project; integration into further distributions is currently pursued.

  19. Recanalization and flow regulate venous thrombus resolution and Matrix metalloproteinases expression in vivo

    Science.gov (United States)

    Chabasse, Christine; Siefert, Suzanne A.; Chaudry, Mohammed; Hoofnagle, Mark H.; Lal, Brajesh K.; Sarkar, Rajabrata

    2016-01-01

    Objective We examined the role of thrombus recanalization and ongoing blood flow in the process of thrombus resolution by comparing two murine in vivo models of deep venous thrombosis. Design of study In CD1 mice, we performed surgical inferior vena cava (IVC) ligation (stasis thrombosis), stenosis (thrombosis with recanalization) or sham procedure. We analyzed thrombus weight over time as a measure of thrombus resolution, and quantified the mRNA and protein levels of Membrane-Type Matrix Metalloproteinases (MT-MMPs) as well as effectors of the plasmin complex at day 4, 8 and 12 post-surgery. Results Despite similar initial thrombus size, the presence of ongoing blood flow (stenosis model) was associated with a 45.91% subsequent improvement in thrombus resolution at day 8, and 12.57% at day 12, as compared with stasis thrombosis (ligation model). Immunoblot and real-time PCR demonstrated a difference in MMP-2 and MMP-9 activity at day 8 between the two models (P=.03 and P=.006 respectively), as well as a difference in MT2-MMP gene expression at day 8 (P=.044) and day 12 (P=0.03) and MT1-MMP protein expression at day 4 (P=.021). Histological analyses revealed distinct areas of recanalization in the thrombi of the stenosis model compared to the ligation model, as well as the recruitment of inflammatory cells, especially macrophages, and a focal pattern of localized expression of MT1-MMP and MT3-MMP proteins surrounding the areas of recanalization in the stenosis model. Conclusions Recanalization and ongoing blood flow accelerate deep venous thrombus resolution in vivo, and are associated with distinct patterns of MT1- and MT3-MMP expression and macrophages localization in areas of intra-thrombus recanalization. PMID:26993683

  20. Thrombus Size is Associated with Etiology of Deep Venous Thrombosis – A Cross-Sectional Study

    OpenAIRE

    Vučić, Nikša; Magdić, Tihana; Krnić, Anton; Včev, Aleksandar; Božić, Dubravko

    2005-01-01

    The aim of this study was to evaluate the impact of risk factors for deep vein thrombosis (DVT) on thrombus sizes in lower extremities. The size and extent of thrombus was scored according to International Consensus Committee for venous disease classification. After the diagnosis of DVT was established and its size scored, predominant risk factors for DVT in each patient were identified (malignant disease, thrombophilia, postoperative state, hormonal therapy, heredity, limb trauma, immobiliza...

  1. Defective angiogenesis delays thrombus resolution: a potential pathogenetic mechanism underlying chronic thromboembolic pulmonary hypertension

    Science.gov (United States)

    Panzenboeck, Adelheid; Winter, Max P; Schubert, Uwe; Voswinckel, Robert; Frey, Maria K; Jakowitsch, Johannes; Alimohammadi, Arman; Hobohm, Lukas; Mangold, Andreas; Bergmeister, Helga; Sibilia, Maria; Wagner, Erwin F; Mayer, Eckhard; Klepetko, Walter; Hoelzenbein, Thomas J; Preissner, Klaus T; Lang, Irene M

    2015-01-01

    Objective Restoration of patency is a natural target of vascular remodeling following venous thrombosis that involves vascular endothelial cells and smooth muscle cells as well as leukocytes. Acute pulmonary emboli usually resolve within six months. However, in some instances, thrombi transform into fibrous vascular obstructions, resulting in occlusion of the deep veins, or in chronic thromboembolic pulmonary hypertension (CTEPH). We proposed that dysregulated thrombus angiogenesis may contribute to thrombus persistence. Approach and Results Mice with an endothelial-cell-specific conditional deletion of vascular endothelial growth factor receptor 2/kinase insert domain protein receptor (VEGF-R2/Kdr) were utilized in a model of stagnant flow venous thrombosis closely resembling human deep vein thrombosis. Biochemical and functional analyses were performed on pulmonary endarterectomy specimens from patients with CTEPH, a human model of non-resolving venous thromboembolism. Endothelial cell-specific deletion of Kdr and subsequent ablation of thrombus vascularization delayed thrombus resolution. In accordance with these findings, organized human CTEPH thrombi were largely devoid of vascular structures. Several vessel-specific genes such as KDR, vascular endothelial cadherin and podoplanin were expressed at lower levels in white CTEPH thrombi than in organizing deep vein thrombi and organizing thrombi from aortic aneurysms. In addition, red CTEPH thrombi attenuated the angiogenic response induced by VEGF. Conclusions In the present work, we propose a mechanism of thrombus non-resolution demonstrating that endothelial cell-specific deletion of Kdr abates thrombus vessel formation, misguiding thrombus resolution. Medical conditions associated with the development of CTEPH may be compromising early thrombus angiogenesis. PMID:24526692

  2. Estimating Wear Of Installed Ball Bearings

    Science.gov (United States)

    Keba, John E.; Mcvey, Scott E.

    1993-01-01

    Simple inspection and measurement technique makes possible to estimate wear of balls in ball bearing, without removing bearing from shaft on which installed. To perform measurement, one observes bearing cage while turning shaft by hand to obtain integral number of cage rotations and to measure, to nearest 2 degrees, number of shaft rotations producing cage rotations. Ratio between numbers of cages and shaft rotations depends only on internal geometry of bearing and applied load. Changes in turns ratio reflect changes in internal geometry of bearing provided measurements made with similar bearing loads. By assuming all wear occurs on balls, one computes effective value for this wear from change in turns ratio.

  3. Q-balls in flat potentials

    International Nuclear Information System (INIS)

    Copeland, Edmund J.; Tsumagari, Mitsuo I.

    2009-01-01

    We study the classical and absolute stability of Q-balls in scalar field theories with flat potentials arising in both gravity-mediated and gauge-mediated models. We show that the associated Q-matter formed in gravity-mediated potentials can be stable against decay into their own free particles as long as the coupling constant of the nonrenormalizable term is small, and that all of the possible three-dimensional Q-ball configurations are classically stable against linear fluctuations. Three-dimensional gauge-mediated Q-balls can be absolutely stable in the thin-wall limit, but are completely unstable in the thick-wall limit.

  4. Computed tomographic and ultrasonographic diagnosis of portal vein tumor thrombus in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Mori, H; Futagawa, S; Hayashi, K; Amagasaki, Y; Ochi, M [Nagasaki Univ. (Japan). School of Medicine

    1982-04-01

    Nine cases of hepatocellular carcinoma which have invaded the intra- and extrahepatic portal vein were evaluated by computed tomography (CT) and ultrasonography (US). The outstanding CT and sonographic features of the portal vein tumor thrombus were described. In CT, contrast opacification of normal portal vein and its major tributaries were not observed, and they were replaced by a soft tissue density mass representing the tumor thrombus. The thrombus measured 35 - 45 Hounsfield units (HU) in precontrast scans and 60 - 80 HU in postcontrast scans. The portal vein tumor thrombus showed a branched pattern of low density in porta hepatis and intrahepatic region due to differences in attenuation coefficients of the thrombus and adjacent noncancerous hepatic parenchyma on postcontrast scans. In ultrasound study, tumor thrombus was recognized as an echogenic solid mass in the porta hepatis obliterating the normal portal venous structures, or as an intraluminal solid mass in the dilated portal vein and its branches. Numerous collateral venous channels surrounding the thrombosed portal vein were also demonstrated on both CT and US. Particular emphasis was placed on the clinical implications of these non-invasive detection of the portal vein tumor thrombosis in patients with hepatocellular carcinoma.

  5. Optical coherence tomography assessment and quantification of intracoronary thrombus: Status and perspectives

    International Nuclear Information System (INIS)

    Porto, Italo; Mattesini, Alessio; Valente, Serafina; Prati, Francesco; Crea, Filippo; Bolognese, Leonardo

    2015-01-01

    Coronary angiography is the “golden standard” imaging technique in interventional cardiology and it is still widely used to guide interventions. A major drawback of this technique, however, is that it is inaccurate in the evaluation and quantification of intracoronary thrombus burden, a critical prognosticator and predictor of intraprocedural complications in acute coronary syndromes. The introduction of optical coherence tomography (OCT) holds the promise of overcoming this important limitation, as near-infrared light is uniquely sensitive to hemoglobin, the pigment of red blood cells trapped in the thrombus. This narrative review will focus on the use of OCT for the assessment, evaluation and quantification of intracoronary thrombosis. - Highlights: • Thrombotic burden in acute coronary syndromes Is not adequately evaluated by standard coronary angiography, whereas Optical Coherence Tomography is exquisitely sensitive to the hemoglobin contained in red blood cells and can be used to precisely quantify thrombus. • Both research and clinical applications have been developed using the OCT-based evaluation of thrombus. In particular, whereas precise quantification scores are useful for comparing antithrombotic therapies in randomized trials, both pharmacological and mechanical, the most important practical applications for OCT-based assessment of thrombus are the individuation of culprit lesions in the context of diffuse atheromata in acute coronary syndromes, and the so-called “delayed stenting” strategies. • Improvements in 3D rendering techniques are on the verge of revolutionizing OCT-based thrombus assessment, allowing extremely precise quantification of the thrombotic burden

  6. Sixty-Four-Section Cardiac Computed Tomography in Mechanical Prosthetic Heart Valve Dysfunction: Thrombus or Pannus.

    Science.gov (United States)

    Gündüz, Sabahattin; Özkan, Mehmet; Kalçik, Macit; Gürsoy, Ozan Mustafa; Astarcioğlu, Mehmet Ali; Karakoyun, Süleyman; Aykan, Ahmet Çağri; Biteker, Murat; Gökdeniz, Tayyar; Kaya, Hasan; Yesin, Mahmut; Duran, Nilüfer Ekşi; Sevinç, Deniz; Güneysu, Tahsin

    2015-12-01

    Distinguishing pannus and thrombus in patients with prosthetic valve dysfunction is essential for the selection of proper treatment. We have investigated the utility of 64-slice multidetector computed tomography (MDCT) in distinguishing between pannus and thrombus, the latter amenable to thrombolysis. Sixty-two (23 men, mean age 44±14 years) patients with suspected mechanical prosthetic valve dysfunction assessed by transesophageal echocardiography were included in this prospective observational trial. Subsequently, MDCT was performed before any treatment was started. Periprosthetic masses were detected by MDCT in 46 patients, and their attenuation values were measured as Hounsfield Units (HU). Patients underwent thrombolysis unless contraindicated, and those with a contraindication or failed thrombolysis underwent surgery. A mass which was completely lysed or surgically detected as a clot was classified as thrombus, whereas a mass which was surgically detected as tissue overgrowth was classified as pannus. A definitive diagnosis could be achieved in 37 patients with 39 MDCT masses (22 thrombus and 17 pannus). The mean attenuation value of 22 thrombotic masses was significantly lower than that in 17 pannus (87±59 versus 322±122; Ppannus from thrombus. Complete lysis was more common for masses with HUpannus overgrowth, whereas a lower value is associated with thrombus formation. A higher attenuation (HU>90) is associated with reduced lysis rates. © 2015 American Heart Association, Inc.

  7. [Clinical analysis of patients with lower extremity deep venous thrombosis complicated with inferior vena cava thrombus].

    Science.gov (United States)

    Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing

    2013-06-04

    To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.

  8. Slow flow and mural thrombus in aortic diseases: Spin-echo MR findings and their differentiation

    International Nuclear Information System (INIS)

    Chung, Jin Wook; Park, Jae Hyung; Han, Man Chung

    1993-01-01

    In order to evaluate the ability of spin-echo MR imaging to differentiate slow flow from mural thrombus in aortic diseases, we reviewed the spin-echo MR images of 13 patients with intraaortic thrombus documented by CT (N=11) or aortography (N=2). Six patients had aortic aneurysms and seven had aortic dissections. Intraaortic mural thrombi were accompanied by flow-related intraluminal signal of various pattern and extents in all 13 patients. On 10 gated MR studies, slow flow regions showed ever-echo rephasing phenomenon (N=8), interslice variation of signal intensities of the intraluminal signal (N=7) and flow-related ghost artifact (N=2). However, these MR flow phenomena were obscured on two of three non-gated studies. Seven of 13 intraaortic thrombi remained hyperintense on T2-weighted second-echo images. In these circumstance, a hypointense boundary layer between slow flow and mural thrombus, which was caused by either ' boundary layer dephasing phenomenon' of slow flow or 'paramagnetic T2 shortening' of fresh clot at the edge of mural thrombus, was very useful in discriminating the area of slow flow from that of mural thrombus. Proper interpretation of spin-echo MR images may obviate the need for phase display imaging or gradient-echo imaging in differentiating slow flow and mural thrombus

  9. Platelet size and density affect shear-induced thrombus formation in tortuous arterioles

    Science.gov (United States)

    Chesnutt, Jennifer K. W.; Han, Hai-Chao

    2013-10-01

    Thrombosis accounts for 80% of deaths in patients with diabetes mellitus. Diabetic patients demonstrate tortuous microvessels and larger than normal platelets. Large platelets are associated with increased platelet activation and thrombosis, but the physical effects of large platelets in the microscale processes of thrombus formation are not clear. Therefore, the objective of this study was to determine the physical effects of mean platelet volume (MPV), mean platelet density (MPD) and vessel tortuosity on platelet activation and thrombus formation in tortuous arterioles. A computational model of the transport, shear-induced activation, collision, adhesion and aggregation of individual platelets was used to simulate platelet interactions and thrombus formation in tortuous arterioles. Our results showed that an increase in MPV resulted in a larger number of activated platelets, though MPD and level of tortuosity made little difference on platelet activation. Platelets with normal MPD yielded the lowest amount of mural thrombus. With platelets of normal MPD, the amount of mural thrombus decreased with increasing level of tortuosity but did not have a simple monotonic relationship with MPV. The physical mechanisms associated with MPV, MPD and arteriole tortuosity play important roles in platelet activation and thrombus formation.

  10. Optical coherence tomography assessment and quantification of intracoronary thrombus: Status and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Porto, Italo, E-mail: italo.porto@gmail.com [Interventional Cardiology Unit, San Donato Hospital, Arezzo (Italy); Mattesini, Alessio; Valente, Serafina [Interventional Cardiology Unit, Careggi Hospital, Florence (Italy); Prati, Francesco [Interventional Cardiology San Giovanni Hospital, Rome (Italy); CLI foundation (Italy); Crea, Filippo [Department of Cardiovascular Sciences, Catholic University of the Sacred Heart, Rome (Italy); Bolognese, Leonardo [Interventional Cardiology Unit, San Donato Hospital, Arezzo (Italy)

    2015-04-15

    Coronary angiography is the “golden standard” imaging technique in interventional cardiology and it is still widely used to guide interventions. A major drawback of this technique, however, is that it is inaccurate in the evaluation and quantification of intracoronary thrombus burden, a critical prognosticator and predictor of intraprocedural complications in acute coronary syndromes. The introduction of optical coherence tomography (OCT) holds the promise of overcoming this important limitation, as near-infrared light is uniquely sensitive to hemoglobin, the pigment of red blood cells trapped in the thrombus. This narrative review will focus on the use of OCT for the assessment, evaluation and quantification of intracoronary thrombosis. - Highlights: • Thrombotic burden in acute coronary syndromes Is not adequately evaluated by standard coronary angiography, whereas Optical Coherence Tomography is exquisitely sensitive to the hemoglobin contained in red blood cells and can be used to precisely quantify thrombus. • Both research and clinical applications have been developed using the OCT-based evaluation of thrombus. In particular, whereas precise quantification scores are useful for comparing antithrombotic therapies in randomized trials, both pharmacological and mechanical, the most important practical applications for OCT-based assessment of thrombus are the individuation of culprit lesions in the context of diffuse atheromata in acute coronary syndromes, and the so-called “delayed stenting” strategies. • Improvements in 3D rendering techniques are on the verge of revolutionizing OCT-based thrombus assessment, allowing extremely precise quantification of the thrombotic burden.

  11. Analysis of early thrombus dynamics in a humanized mouse laser injury model.

    Science.gov (United States)

    Wang, Weiwei; Lindsey, John P; Chen, Jianchun; Diacovo, Thomas G; King, Michael R

    2014-01-01

    Platelet aggregation and thrombus formation at the site of injury is a dynamic process that involves the continuous addition of new platelets as well as thrombus rupture. In the early stages of hemostasis (within minutes after vessel injury) this process can be visualized by transfusing fluorescently labeled human platelets and observing their deposition and detachment. These two counterbalancing events help the developing thrombus reach a steady-state morphology, where it is large enough to cover the injured vessel surface but not too large to form a severe thrombotic occlusion. In this study, the spatial and temporal aspects of early stage thrombus dynamics which result from laser-induced injury on arterioles of cremaster muscle in the humanized mouse were visualized using fluorescent microscopy. It was found that rolling platelets show preference for the upstream region while tethering/detaching platelets were primarily found downstream. It was also determined that the platelet deposition rate is relatively steady, whereas the effective thrombus coverage area does not increase at a constant rate. By introducing a new method to graphically represent the real time in vivo physiological shear stress environment, we conclude that the thrombus continuously changes shape by regional growth and decay, and neither dominates in the high shear stress region.

  12. Crystal ball single event display

    International Nuclear Information System (INIS)

    Grosnick, D.; Gibson, A.; Allgower, C.; Alyea, J.; Argonne National Lab., IL

    1997-01-01

    The Single Event Display (SED) is a routine that is designed to provide information graphically about a triggered event within the Crystal Ball. The SED is written entirely in FORTRAN and uses the CERN-based HICZ graphing package. The primary display shows the amount of energy deposited in each of the NaI crystals on a Mercator-like projection of the crystals. Ten different shades and colors correspond to varying amounts of energy deposited within a crystal. Information about energy clusters is displayed on the crystal map by outlining in red the thirteen (or twelve) crystals contained within a cluster and assigning each cluster a number. Additional information about energy clusters is provided in a series of boxes containing useful data about the energy distribution among the crystals within the cluster. Other information shown on the event display include the event trigger type and data about π o 's and η's formed from pairs of clusters as found by the analyzer. A description of the major features is given, along with some information on how to install the SED into the analyzer

  13. Static Load Distribution in Ball Bearings

    Science.gov (United States)

    Ricci, Mario

    2010-01-01

    A numerical procedure for computing the internal loading distribution in statically loaded, single-row, angular-contact ball bearings when subjected to a known combined radial and thrust load is presented. The combined radial and thrust load must be applied in order to avoid tilting between inner and outer rings. The numerical procedure requires the iterative solution of Z + 2 simultaneous nonlinear equations - where Z is the number of the balls - to yield an exact solution for axial and radial deflections, and contact angles. Numerical results for a 218 angular-contact ball bearing have been compared with those from the literature and show significant differences in the magnitudes of the ball loads, contact angles, and the extent of the loading zone.

  14. On the formation of ball lightning

    International Nuclear Information System (INIS)

    Silberg, P.A.

    1981-01-01

    A plasma continuum model for the formation of ball lightning is developed based on a substantial number of reports that the ball is often in the discharge column of a previous lightning stroke. The usual method of setting up the plasma equation for a one-component electron plasma is used. An approximate equation for the plasma is derived from the describing equation which is then solved exactly in terms of the Jacobi elliptic functions. The formation of the ball is based on a nonlinearity of the plasma equation which uner certain circumstances permits the field to collapse into a small region. This collapse is interpreted to be ball lightning. The approximate equation derived for the plasma has the same form as a previous equation used to describe the formation of the fireball plasma. (author)

  15. Dolphin underwater bait-balling behaviors in relation to group and prey ball sizes.

    Science.gov (United States)

    Vaughn-Hirshorn, Robin L; Muzi, Elisa; Richardson, Jessica L; Fox, Gabriella J; Hansen, Lauren N; Salley, Alyce M; Dudzinski, Kathleen M; Würsig, Bernd

    2013-09-01

    We characterized dusky dolphin (Lagenorhynchus obscurus) feeding behaviors recorded on underwater video, and related behaviors to variation in prey ball sizes, dolphin group sizes, and study site (Argentina versus New Zealand, NZ). Herding behaviors most often involved dolphins swimming around the side or under prey balls, but dolphins in Argentina more often swam under prey balls (48% of passes) than did dolphins in NZ (34% of passes). This result may have been due to differences in group sizes between sites, since groups are larger in Argentina. Additionally, in NZ, group size was positively correlated with proportion of passes that occurred under prey balls (pdolphins in Argentina more often swam through prey balls (8% of attempts) than did dolphins in NZ (4% of attempts). This result may have been due to differences in prey ball sizes between sites, since dolphins fed on larger prey balls in Argentina (>74m(2)) than in NZ (maximum 33m(2)). Additionally, in NZ, dolphins were more likely to swim through prey balls to capture fish when they fed on larger prey balls (p=0.025). Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Hermitian harmonic maps into convex balls

    International Nuclear Information System (INIS)

    Li Zhenyang; Xi Zhang

    2004-07-01

    In this paper, we consider Hermitian harmonic maps from Hermitian manifolds into convex balls. We prove that there exist no non-trivial Hermitian harmonic maps from closed Hermitian manifolds into convex balls, and we use the heat flow method to solve the Dirichlet problem for Hermitian harmonic maps when the domain is compact Hermitian manifold with non-empty boundary. The case where the domain manifold is complete(noncompact) is also studied. (author)

  17. Thermoelastoplastic Deformation of a Multilayer Ball

    Science.gov (United States)

    Murashkin, E. V.; Dats, E. P.

    2017-09-01

    The problem of centrally symmetric deformation of a multilayer elastoplastic ball in the process of successive accretion of preheated layers to its outer surface is considered in the framework of small elastoplastic deformations. The problems of residual stress formation in the elastoplastic ball with an inclusion and a cavity are solved under various mechanical boundary conditions on the inner surface and for prescribed thermal compression distributions. The graphs of residual stress and displacement fields are constructed.

  18. Potential application of labeled antibodies for thrombus detection

    Energy Technology Data Exchange (ETDEWEB)

    Ezekowitz, M.D.; Coller, B.S.; Srivastava, S.C.

    1986-01-01

    Labeling platelets with monoclonal antibodies in whole blood for imaging thrombi is less cumbersome than the established /sup 111/In-oxine method. 7E3, a murine monoclonal antibody directed against glycoprotein IIb and/or IIIa on both human and dog platelets was used to label canine platelets. Thrombi were induced by transcatheter placement of a copper coil followed by electrocoagulation. 7E3 was iodinated with /sup 131/I and labelled with /sup 111/In using 7E3-DTPA conjugate. Whole blood was incubated with 0.5 - 1.0 ..mu..g labeled 7E3/mL blood. In 4/4 dogs, experimental deep vein thrombi were identified using both /sup 131/I-and /sup 111/In-labeled 7E3 within 5-30 min after injection. For both isotopes, 1 h blood clearance was 54 + - 9%. In 1/3 dogs, experimental coronary thrombus could be identified ex vivo at 4 h. Clot to blood ratios ranged between 7 to 13:1. Using the /sup 111/In-oxine method, 0/3 coronary thrombi were seen. Thus, /sup 131/I-and /sup 111/In-labeled 7E3 may be used to readily identify peripheral venous thrombi. For reliable and prompt identification of coronary thrombi, more rapid clearance of the labeled platelets is required.

  19. Interventional treatment for old thrombus in iliofemoral deep veins

    International Nuclear Information System (INIS)

    Qian Jun; Jiang Hong; Yang Yang

    2009-01-01

    Objective: To evaluate interventional management in treating old thrombus in iliofemoral deep veins. Methods: The clinical data and the interventional treatment results of 32 patients with chronic iliofemoral deep venous thrombosis were retrospectively reviewed and analyzed. Results: Technical success was achieved in 30 patients (93.8%). Twenty-nine endovascular stents were successfully placed in 25 patients. Postoperative therapeutic effects were as follows: grade I was obtained in 4 cases (12.5%), grade II in 16 cases (50.0%), grade III in 10 cases (31.3%) and grade IV in 2 cases (6.3%). Twenty-nine patients were followed-up for a mean period of 13.0 ± 6.8 months, and three patients were lost in touch. The follow-up results were as follows: grade I was seen in 3 cases (10.3%), grade II in 14 cases (48.3%) and grade III in 12 cases (41.4%). Conclusion: Interventional management is a minimally-invasive, safe and effective treatment for chronic iliofemoral deep venous thrombosis. (authors)

  20. Safety of primary percutaneous coronary intervention with and without (selective) thrombus aspiration

    International Nuclear Information System (INIS)

    Farman, M. T.; Saghir, T.; Rizvi, N. H.; Khan, N.; Zaman, K. S.; Sial, J. A.; Malik, A.

    2014-01-01

    Objective: To determine the safety and efficacy of selective thrombus aspiration during Primary Percutaneous Coronary Intervention (PCI). Methods: This observational prospective study was conducted in the catheterization laboratory of a tertiary care cardiovascular centre. A total of 150 consecutive patients who underwent primary PCI were enrolled. Aspiration was done only when thrombus burden was considered significant. After completion of procedure angiographic and electrocardiographic signs were recorded and clinical follow up was documented up to 1 year. Results: No significant difference among the groups was found in age, height, weight and other risk factors like Hypertension, Diabetes Mellitus and Smoking. In general, left anterior descending artery was culprit in 65 % of patients and more than 90 % of culprit vessels had visible thrombus. Multivessel disease was present in 38 % of patients and 22.7% had past history of myocardial infarction. Out of 150 patients 117 (78%) underwent thrombus aspiration. No significant difference was found in ST resolution within 60 minutes (72.6 vs 81.8 %; P<0.285) and myocardial blush grade II and III (41.9 vs 27.3 %; P<0.128). No difference in event free survival was observed among the two groups (80.3 vs 84.8 %; P<0.708) at one year. Conclusion: Selective thrombus aspiration in definite thrombus laden arteries and no aspiration in low or negligible thrombus burden vessels may be a safe and effective strategy in patients undergoing primary PCI. Overall poor risk profile of our patients as compared to western population necessitates further evaluation of this matter in randomized studies. (author)

  1. Frequency of left ventricular thrombus after anterior wall st-segment elevation acute myocardial infarction

    International Nuclear Information System (INIS)

    Iqbal, M.W.; Fayyaz, A.

    2014-01-01

    Left ventricular thrombus (LVT) formation is a well known complication seen in patients presenting with acute anterior wall ST-segment elevation myocardial infarction (STEMI). In previous studies the incidence of this complication, after acute myocardial infarction (AMI) has been reported to be 4% to 60% in large anterior wall STEMI, depending significantly upon the method as well as time of reperfusion therapy after STEMI. Objective: The objective of this descriptive case series study was to evaluate the frequency of left ventricular thrombus formation in patients after acute anterior wall ST-Segment elevation myocardial infarction. Methodology: In this study, 100 patients with anterior wall STEMI presenting to cardiac emergency or coronary care unit (CCU) of Cardiac complex, Gulab Devi Hospital, were selected on non-probability, purposive sampling meeting inclusion criteria, after taking written informed consent. All the patients were treated initially for management of acute STEMI, including use of thrombolytics where indicated. 2-D Transthoracic echocardiography (TTE) was performed during the same admission to assess presence of LV thrombus (LVT). Results: The mean age of the patients was 54.3 +- 11.4 years. There were 84(84%) male patients and 16 (16%) female patients. LVT was present in 28 (28%) patients on TTE. Among those, there were 23 (82.1%) male and 5 (17.9%) female patients. However, out of 84 male patients 27.4% develop LVT and among 16 female patients this ratio was 31.3%. The LV thrombus was independent of age and gender. LV thrombus was significantly less in thrombolytic group as compared to those who were not given this therapy, i.e. p value <0.05. Conclusion: Patients with anterior wall acute STEMI not infrequently develop the complication of development of LV thrombus. In this study the frequency of LV thrombus formation after anterior wall acute STEMI was 28%. (author)

  2. Recanalization and flow regulate venous thrombus resolution and matrix metalloproteinase expression in vivo.

    Science.gov (United States)

    Chabasse, Christine; Siefert, Suzanne A; Chaudry, Mohammed; Hoofnagle, Mark H; Lal, Brajesh K; Sarkar, Rajabrata

    2015-01-01

    We examined the role of thrombus recanalization and ongoing blood flow in the process of thrombus resolution by comparing two murine in vivo models of deep venous thrombosis. In CD1 mice, we performed surgical inferior vena cava ligation (stasis thrombosis), stenosis (thrombosis with recanalization), or sham procedure. We analyzed thrombus weight over time as a measure of thrombus resolution and quantified the messenger RNA and protein levels of membrane-type matrix metalloproteinases (MT-MMPs) as well as effectors of the plasmin complex at days 4, 8, and 12 after surgery. Despite similar initial thrombus size, the presence of ongoing blood flow (stenosis model) was associated with a 45.91% subsequent improvement in thrombus resolution at day 8 and 12.57% at day 12 compared with stasis thrombosis (ligation model). Immunoblot and real-time polymerase chain reaction analysis demonstrated a difference in MMP-2 and MMP-9 activity at day 8 between the two models (P = .03 and P = .006, respectively) as well as a difference in MT2-MMP gene expression at day 8 (P = .044) and day 12 (P = .03) and MT1-MMP protein expression at day 4 (P = .021). Histologic analyses revealed distinct areas of recanalization in the thrombi of the stenosis model compared with the ligation model as well as the recruitment of inflammatory cells, especially macrophages, and a focal pattern of localized expression of MT1-MMP and MT3-MMP proteins surrounding the areas of recanalization in the stenosis model. Recanalization and ongoing blood flow accelerate deep venous thrombus resolution in vivo and are associated with distinct patterns of MT1-MMP and MT3-MMP expression and macrophage localization in areas of intrathrombus recanalization. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  3. Effect of red blood cells on platelet activation and thrombus formation in tortuous arterioles

    Directory of Open Access Journals (Sweden)

    Jennifer K. W. Chesnutt

    2013-12-01

    Full Text Available Thrombosis is a major contributor to cardiovascular disease, which can lead to myocardial infarction and stroke. Thrombosis may form in tortuous microvessels, which are often seen throughout the human body, but the microscale mechanisms and processes are not well understood. In straight vessels, the presence of red blood cells (RBCs is known to push platelets toward walls, which may affect platelet aggregation and thrombus formation. However in tortuous vessels, the effects of RBC interactions with platelets in thrombosis are largely unknown. Accordingly, the objective of this work was to determine the physical effects of RBCs, platelet size, and vessel tortuosity on platelet activation and thrombus formation in tortuous arterioles. A discrete element computational model was used to simulate the transport, collision, adhesion, aggregation, and shear-induced platelet activation of hundreds of individual platelets and RBCs in thrombus formation in tortuous arterioles. Results showed that high shear stress near the inner sides of curved arteriole walls activated platelets to initiate thrombosis. RBCs initially promoted platelet activation, but then collisions of RBCs with mural thrombi reduced the amount of mural thrombus and the size of emboli. In the absence of RBCs, mural thrombus mass was smaller in a highly tortuous arteriole compared to a less tortuous arteriole. In the presence of RBCs however, mural thrombus mass was larger in the highly tortuous arteriole compared to the less tortuous arteriole. As well, smaller platelet size yielded less mural thrombus mass and smaller emboli, either with or without RBCs. This study shed light on microscopic interactions of RBCs and platelets in tortuous microvessels, which have implications in various pathologies associated with thrombosis and bleeding.

  4. Aerodynamic drag of modern soccer balls.

    Science.gov (United States)

    Asai, Takeshi; Seo, Kazuya

    2013-12-01

    Soccer balls such as the Adidas Roteiro that have been used in soccer tournaments thus far had 32 pentagonal and hexagonal panels. Recently, the Adidas Teamgeist II and Adidas Jabulani, respectively having 14 and 8 panels, have been used at tournaments; the aerodynamic characteristics of these balls have not yet been verified. Now, the Adidas Tango 12, having 32 panels, has been developed for use at tournaments; therefore, it is necessary to understand its aerodynamic characteristics. Through a wind tunnel test and ball trajectory simulations, this study shows that the aerodynamic resistance of the new 32-panel soccer ball is larger in the high-speed region and lower in the middle-speed region than that of the previous 14- and 8-panel balls. The critical Reynolds number of the Roteiro, Teamgeist II, Jabulani, and Tango 12 was ~2.2 × 10(5) (drag coefficient, C d  ≈ 0.12), ~2.8 × 10(5) (C d  ≈ 0.13), ~3.3 × 10(5) (C d  ≈ 0.13), and ~2.4 × 10(5) (C d  ≈ 0.15), respectively. The flight trajectory simulation suggested that the Tango 12, one of the newest soccer balls, has less air resistance in the medium-speed region than the Jabulani and can thus easily acquire large initial velocity in this region. It is considered that the critical Reynolds number of a soccer ball, as considered within the scope of this experiment, depends on the extended total distance of the panel bonds rather than the small designs on the panel surfaces.

  5. Effect of a ball skill intervention on children's ball skills and cognitive functions

    NARCIS (Netherlands)

    Westendorp-Haverdings, Marieke; Houwen, Suzanne; Hartman, Esther; Mombarg, Remo; Smith, Joanne; Visscher, Chris

    Purpose: This study examined the effect of a 16-wk ball skill intervention on the ball skills, executive functioning (in terms of problem solving and cognitive flexibility), and in how far improved executive functioning leads to improved reading and mathematics performance of children with learning

  6. Optical and Acoustic Sensor-Based 3D Ball Motion Estimation for Ball Sport Simulators †

    Directory of Open Access Journals (Sweden)

    Sang-Woo Seo

    2018-04-01

    Full Text Available Estimation of the motion of ball-shaped objects is essential for the operation of ball sport simulators. In this paper, we propose an estimation system for 3D ball motion, including speed and angle of projection, by using acoustic vector and infrared (IR scanning sensors. Our system is comprised of three steps to estimate a ball motion: sound-based ball firing detection, sound source localization, and IR scanning for motion analysis. First, an impulsive sound classification based on the mel-frequency cepstrum and feed-forward neural network is introduced to detect the ball launch sound. An impulsive sound source localization using a 2D microelectromechanical system (MEMS microphones and delay-and-sum beamforming is presented to estimate the firing position. The time and position of a ball in 3D space is determined from a high-speed infrared scanning method. Our experimental results demonstrate that the estimation of ball motion based on sound allows a wider activity area than similar camera-based methods. Thus, it can be practically applied to various simulations in sports such as soccer and baseball.

  7. PATHOPHYSIOLOGY STROKE NON-HEMORRHAGIC ET CAUSA THROMBUS

    Directory of Open Access Journals (Sweden)

    Aji Kristianto Wijaya

    2013-10-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Stroke is one of the most common cause of death worldwide and the third leading cause of death in the United States. Stroke composed 90,000 deaths of women and 60,000 men each year. In Indonesia, 8 of 1000 people suffered a stroke. Stroke is divided into two, non-hemorrhagic stroke and hemorrhagic stroke. Most of them (80% is non-hemorrhagic stroke. Non-hemorrhagic stroke can be caused by thrombi or emboli. Understanding the pathophysiology of non-hemorrhagic stroke caused by a thrombus is very important in regard with providing appropriate patient management. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  8. [Recurrent right atrial thrombus in a patient with atrial fibrillation and heart failure].

    Science.gov (United States)

    Elikowski, Waldemar; Wróblewski, Dariusz; Małek-Elikowska, Małgorzata; Mazurek, Andrzej; Foremska-Iciek, Joanna; Łazowski, Stanisław

    2015-11-01

    Atrial fibrillation and heart failure are factors predisposing to locally formed intracardiac thrombosis, which is usually localized in left-sided chambers. A case report. The authors present a case of a 50-year-old male with permanent atrial fibrillation and dilated cardiomyopathy in whom recurrent right atrial thrombus was observed. Initially, the lesion was detected in echocardiography while he was hospitalized due to extensive right-sided pneumonia. The thrombus was successfully treated with heparin, followed by warfarin. Even though the patient continued warfarin use properly, there was recurrence of the thrombus two years later during a new episode of heart failure exacerbation. Because the thrombus was resistant to intensified anticoagulation, cardiac surgery was needed. A large (30 x 25 mm) pedunculated thrombus, as well as two smaller ones (each of 10 x 10 mm) attached closely to the atrial wall and previously not detected either by echocardiography or by magnetic resonance imaging, were excited. A partially organized pattern of the thrombi in histological examination can explain lack of anticoagulation effectiveness. © 2015 MEDPRESS.

  9. Resectable hepatoblastoma with tumor thrombus extending into the right atrium after chemotherapy: A case report

    Directory of Open Access Journals (Sweden)

    Kosuke Endo

    2016-04-01

    Full Text Available Hepatoblastoma with intraatrial tumor thrombus is relatively rare. We report a case of hepatoblastoma with tumor thrombus extending into the right atrium, which responded well to chemotherapy and was resected using extracorporeal circulation. A 4-year-old girl was referred to our hospital because of abdominal distention and tenderness. A computed tomography (CT scan showed a large tumor occupying the left 3 segments of the liver with tumor thrombus extending into the right atrium. There was also a small intrahepatic metastasis in the right lobe of the liver. She was diagnosed with hepatoblastoma on the basis of the results of open biopsy. Neoadjuvant chemotherapy with an intense CDDP-based regimen was performed. The tumor responded well to chemotherapy, and intrahepatic metastasis became undetectable on CT scan, although the tumor thrombus remained in the right atrium. After 7 courses of chemotherapy, we performed resection using extracorporeal circulation. The postoperative course was uneventful, and adjuvant chemotherapy was started 10 days after the operation. Her serum alpha-fetoprotein (AFP level decreased to the normal range, and she was free of disease for 1 year after the operation. Tumor resection using extracorporeal circulation can be performed safely and is justified in patients with intraatrial tumor thrombus.

  10. Comparison of the effect of dabigatran and dalteparin on thrombus stability in a murine model of venous thromboembolism.

    Science.gov (United States)

    Shaya, S A; Saldanha, L J; Vaezzadeh, N; Zhou, J; Ni, R; Gross, P L

    2016-01-01

    ESSENTIALS: Does thrombus stability alter the presentation of venous thromboembolism and do anticoagulants alter this? In a murine model, we imaged a femoral vein thrombus and quantified emboli in the pulmonary arteries. Dabigatran decreases thrombus stability via factor XIII increasing embolization and pulmonary emboli. This cautions against the unapproved use of dabigatran for acute initial treatment of deep vein thrombosis. Venous thromboembolism (VTE) is a collective term for deep vein thrombosis (DVT) and pulmonary embolism (PE). Thrombus instability possibly contributes to progression of DVT to PE, and direct thrombin inhibitors (DTIs) may alter this. To develop a model to assess thrombus stability and its link to PE burden, and identify whether DTIs, in contrast to low-molecular-weight heparin (LMWH), alter this correlation. Twelve minutes after ferric chloride-induced thrombus formation in the femoral vein of female mice, saline, dalteparin (LMWH) or dabigatran (DTI) was administered. Thrombus size and embolic events breaking off from the thrombus were quantified before treatment and at 10-min intervals after treatment for 2 h using intravital videomicroscopy. Lungs were stained for the presence of PE. Thrombus size was similar over time and between treatment groups. Total and large embolic events and pulmonary emboli were highest after treatment with dabigatran. Variations in amounts of pulmonary embolic events were not attributed to variations in thrombus size. Large embolic events correlated with the number of emboli per lung slice independent of treatment. Embolization in factor XIII deficient (FXIII(-/-) ) saline-treated mice was greater than that in wild-type (WT) saline-treated mice, but was similar to WT dabigatran-treated mice. We have developed a mouse model of VTE that can quantify emboli and correlate this with PE burden. Consistent with clinical data, dabigatran, a DTI, acutely decreases thrombus stability and increases PE burden compared with

  11. Effect of a ball skill intervention on children's ball skills and cognitive functions.

    Science.gov (United States)

    Westendorp, Marieke; Houwen, Suzanne; Hartman, Esther; Mombarg, Remo; Smith, Joanne; Visscher, Chris

    2014-02-01

    This study examined the effect of a 16-wk ball skill intervention on the ball skills, executive functioning (in terms of problem solving and cognitive flexibility), and in how far improved executive functioning leads to improved reading and mathematics performance of children with learning disorders. Ninety-one children with learning disorders (age 7-11 yr old) were recruited from six classes in a Dutch special-needs primary school. The six classes were assigned randomly either to the intervention or to the control group. The control group received the school's regular physical education lessons. In the intervention group, ball skills were practiced in relative static, simple settings as well as in more dynamic and cognitive demanding settings. Both groups received two 40-min lessons per week. Children's scores on the Test of Gross Motor Development-2 (ball skills), Tower of London (problem solving), Trail Making Test (cognitive flexibility), Dutch Analysis of Individual Word Forms (reading), and the Dutch World in Numbers test (mathematics) at pretest, posttest, and retention test were used to examine intervention effects. The results showed that the intervention group significantly improved their ball skills, whereas the control group did not. No intervention effects were found on the cognitive parameters. However, within the intervention group, a positive relationship (r = 0.41, P = 0.007) was found between the change in ball skill performance and the change in problem solving: the larger children's improvement in ball skills, the larger their improvement in problem solving. The present ball skill intervention is an effective instrument to improve the ball skills of children with learning disorders. Further research is needed to examine the effect of the ball skill intervention on the cognitive parameters in this population.

  12. Laser Sintering Technology and Balling Phenomenon.

    Science.gov (United States)

    Oyar, Perihan

    2018-02-01

    The aim of this review was to evaluate the balling phenomenon which occurs typically in Selective Laser Sintering (SLS). The balling phenomenon is a typical SLS defect, and observed in laser sintered powder, significantly reduces the quality of SLS, and hinders the further development of SLS Technology. Electronic database searches were performed using Google Scholar. The keywords "laser sintering, selective laser sintering, direct metal laser melting, and balling phenomenon" were searched in title/abstract of publications, limited to December 31, 2016. The inclusion criteria were SLS, balling phenomenon, some alloys (such as Cr-Co, iron, stainless steel, and Cu-based alloys) mechanical properties, microstructure and bond strength between metal-ceramic crown, laboratory studies, full text, and in English language. A total of 100 articles were found the initial search and yielded a total of 50 studies, 30 of which did not fulfill the inclusion criteria and were therefore excluded. In addition, 20 studies were found by screening the reference list of all included publications. Finally, 40 studies were selected for this review. The method in question is regulated by powder material characteristics and the conditions of laser processing. The procedure of formation, affecting factors, and the mechanism of the balling effect are very complex.

  13. Flight trajectory of a rotating golf ball with grooves

    Science.gov (United States)

    Baek, Moonheum; Kim, Jooha; Choi, Haecheon

    2014-11-01

    Dimples are known to reduce drag on a sphere by the amount of 50% as compared to a smooth surface. Despite the advantage of reducing drag, dimples deteriorate the putting accuracy owing to their sharp edges. To minimize this putting error but maintain the same flight distance, we have devised a grooved golf ball (called G ball hereafter) for several years. In this study, we modify the shape and pattern of grooves, and investigate the flow characteristics of the G ball by performing wind-tunnel experiments at the Reynolds numbers of 0 . 5 ×105 - 2 . 5 ×105 and the spin ratios (ratio of surface velocity to the free-stream velocity) of 0 - 0.6 that include the real golf-ball velocity and rotational speed. We measure the drag and lift forces on the rotating G ball and compare them with those of a smooth ball and two well-known dimpled balls. The lift-to-drag ratio of the G ball is much higher than that of a smooth ball and is in between those of the two dimpled balls. The trajectories of flying golf balls are computed. The flight distance of G ball is almost the same as that of one dimpled ball but slightly shorter than that of the other dimpled ball. The fluid-dynamic aspects of these differences will be discussed at the talk. Supported by 2011-0028032, 2014M3C1B1033980.

  14. Iron-Deficiency Anemia Leading to Transient Ischemic Attacks due to Intraluminal Carotid Artery Thrombus

    Directory of Open Access Journals (Sweden)

    H. Z. Batur Caglayan

    2013-01-01

    Full Text Available Reactive thrombocytosis secondary to iron-deficiency anemia (IDA is a rare but recognized cause of stroke. We report the case of a patient with iron-deficiency anemia presenting with multiple transient ischemic attacks (TIA due to intraluminal thrombus of an internal carotid artery. The putative mechanisms underlying anemia and stroke syndromes are not completely understood, and it is believed that iron deficiency may cause ischemic stroke by several potential mechanisms. Thrombocytosis is often associated with iron deficiency, and microcytosis produces a reduction in the red cell deformability and could produce a hypercoagulable state. The platelet count and function observed in iron-deficiency anemia could act synergistically to promote thrombus formation, especially in the setting of an underlying atherosclerotic disease. The presence of floating thrombus in a patient with clinical and MRI evidence of stroke represents a significant therapeutic dilemma and requires immediate decision about treatment.

  15. Mural Thrombus in the Normal-Appearing Descending Thoracic Aorta of a Chronic Smoker

    Science.gov (United States)

    Habib, Habib; Hsu, Judy; Winchell, Patricia Jo; Daoko, Joseph

    2013-01-01

    Thrombus formation in an atherosclerotic or aneurysmal descending thoracic aorta is a well-described, frequently encountered vascular condition. In comparison, thrombus formation in a normal-appearing descending thoracic aorta is reported far less often. We describe the case of a 46-year-old woman who had splenic and renal infarctions secondary to embolic showers from a large, mobile thrombus in a morphologically normal proximal descending thoracic aorta. After the patient underwent anticoagulation, stent-grafting, and surgical bypass to correct an arterial blockage caused by the stent-graft, she resumed a relatively normal life. In contrast with other cases of a thrombotic but normal-appearing descending thoracic aorta, this patient had no known malignancy or systemic coagulative disorders; her sole risk factor was chronic smoking. We discuss our patient's case and review the relevant medical literature, focusing on the effect of smoking on coagulation physiology. PMID:24391341

  16. The accumulation of a platelet protein, thrombospondin, at the site of arterial thrombus formation: Preliminary report

    International Nuclear Information System (INIS)

    Perlman, S.B.; Hammes, R.J.; Besozzi, M.C.; Folts, J.D.; Mosher, D.F.

    1987-01-01

    There are many methods available for the detection of thrombosis, none of which are noninvasive, rapid and accurate. Thrombosponding is a platelet protein that is present in the developing thrombus and may be an effective substance to use for imaging thrombosis. Vascular stenosis and thrombosis were produced in coronary, carotid and femoral arteries in eleven adult mongrel dogs. 131 I labeled thrombosponding was administered to each animal to determine whether the radiotracer accumulated at the site of thrombus formation. The radioactivity per gram of vessels with thrombi was significantly different from the control vessels or whole blood (p=0.0037 and p=0.015, respectively, paired t-test). This preliminary work suggests that iodinated thrombosponding accumulates at the site of thrombus formation. Labeled thrombosponding may be a rapid, safe and accurate method of detecting arterial thrombosis. (orig.)

  17. [Stroke due to infective endocarditis diagnosed by the retrieved thrombus: a case report].

    Science.gov (United States)

    Nakanishi, Kaoru; Kawano, Hiroyuki; Amano, Tatsuo; Omori, Yoshihiko; Kanma, Hiroshi; Hirano, Teruyuki

    2018-01-26

    A 80-years-old woman suddenly presented with aphasia, right hemiparesis, and dysesthesia. MRA showed the left middle cerebral artery occlusion. She was diagnosed as hyperacute ischemic stroke. She was treated with intravenous recombinant tissue plasminogen activator and underwent endovascular thrombectomy. On admission, she had a fever and high C reactive protein, and was treated with antibiotic therapy. The pathological diagnosis of the retrieved thrombus revealed the cluster of the gram positive cocci. The blood culture was negative and thransthoracic echocardiogram did not detect the vegetation. She was finally diagnosed as cardioembolic stroke due to infective endocarditis based on the pathological diagnosis of the retrieved thrombus. The pathological diagnosis of the retrieved thrombus was quite important to clarify the cause of ischemic stroke.

  18. Electrostatic charge bounds for ball lightning models

    International Nuclear Information System (INIS)

    Stephan, Karl D

    2008-01-01

    Several current theories concerning the nature of ball lightning predict a substantial electrostatic charge in order to account for its observed motion and shape (Turner 1998 Phys. Rep. 293 1; Abrahamson and Dinniss 2000 Nature 403 519). Using charged soap bubbles as a physical model for ball lightning, we show that the magnitude of charge predicted by some of these theories is too high to allow for the types of motion commonly observed in natural ball lightning, which includes horizontal motion above the ground and movement near grounded conductors. Experiments show that at charge levels of only 10-15 nC, 3-cm-diameter soap bubbles tend to be attracted by induced charges to the nearest grounded conductor and rupture. We conclude with a scaling rule that can be used to extrapolate these results to larger objects and surroundings

  19. Ball-and-socket ankle joint

    International Nuclear Information System (INIS)

    Pistoia, F.; Ozonoff, M.B.; Wintz, P.; Hartford Hospital, CT

    1987-01-01

    The ball-and-socket ankle joint is a malformation of the ankle in which the articular surface of the talus is hemispherical in both the anteroposterior and lateral projections and has a congruent, concave tibial articular surface. Fourteen patients with this condition were identified retrospectively. Thirteen patients were thought to have the congenital type of ball-and-socket ankle joint which in many was associated with tarsal coalition, short limb, and ray fusion and deletion anomalies. One case of the acquired type, demonstrating less geometric rounding of the talar margins, was seen in a patient with myelomeningocele, probably resulting from sensory and motor deficits. Although the exact etiology of the congenital type is unknown, its association with other malformations suggests that the ball-and-socket ankle joint results from an overall maldevelopment of the ankle and foot. (orig.)

  20. Quantity of residual thrombus after successful catheter-directed thrombolysis for iliofemoral deep venous thrombosis correlates with recurrence.

    Science.gov (United States)

    Aziz, F; Comerota, A J

    2012-08-01

    Iliofemoral deep venous thrombosis (IFDVT) is an independent risk factor for recurrent DVT. It has been observed that recurrent DVT correlates with residual thrombus. This study evaluates whether risk of recurrence is related to the amount of residual thrombus following catheter-directed thrombolysis (CDT) for IFDVT. Patients who underwent CDT for IFDVT had their degree of lysis quantified by a reader blind to the patients' long-term clinical outcome. Patients were classified into two groups, ≥50% and thrombus. Recurrence was defined as a symptomatic presentation with image verification of new or additional thrombus. A total of 75 patients underwent CDT for IFDVT. Median follow-up was 35.9 months. Sixty-eight patients (91%) had no evidence of recurrence and seven (9%) developed recurrence. Of the patients who had ≥50% (mean 80%) residual thrombus, 50% (4/8) experienced recurrence, but in those with thrombus, only 5% (3/67) had recurrent DVT (P = 0.0014). The burden of residual thrombus at completion of CDT correlates with the risk of DVT recurrence. Patients having CDT for IFDVT had a lower risk of recurrence than expected. Successful clearing of acute clot in IFDVT patients significantly reduces the recurrence risk compared to patients with a large residual thrombus burden. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Extensive tumor thrombus of hepatocellular carcinoma in the entire portal venous system detected on fluorodeoxyglucose positron emission tomography computed tomography

    International Nuclear Information System (INIS)

    Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Puranik, Ameya; Rangarajan, Venkatesh

    2013-01-01

    Detection of thrombus is usually an incidental finding on fluorodeoxyglucose positron emission tomography/computed tomography studies. Nevertheless this is an important finding in terms of disease prognostication and in planning the treatment strategy. We herein report a case of a 50-years-old male, a diagnosed case of hepatocellular carcinoma with extensive hypermetabolic thrombus involving the entire portal venous system. (author)

  2. Severe reversible dilated cardiomyopathy associated with a large left ventricular thrombus in a young child with middle aortic syndrome

    OpenAIRE

    Ponniah, U; Overholt, E

    2014-01-01

    this article reports a case of a seven-year girl who presented with severe dilated cardiomyopathy (DCM) associated with a large thrombus in the left ventricle (LV). She had a long segment stenosis of the lower thoracic descending aorta, possibly due to non-specific aortitis and underwent successful stent angioplasty. The LV thrombus resolved after heparin without sequelae.

  3. Surgical Treatment of Renal Cell Carcinoma with Inferior Vena Cava Thrombus: Using Liver Mobilization Technique to Avoid Cardiopulmonary Bypass

    Directory of Open Access Journals (Sweden)

    Tawatchai Taweemonkongsap

    2008-04-01

    CONCLUSION: These results support the aggressive surgical removal of RCC with IVC thrombus as the initial treatment. Most of the thrombi can be approached and safely controlled by a transabdominal approach without any form of bypass. Tumour thrombus removal provides a high survival chance and offers improvement in quality of life.

  4. On longevity of I-ball/oscillon

    Energy Technology Data Exchange (ETDEWEB)

    Mukaida, Kyohei [Kavli IPMU (WPI), UTIAS, The University of Tokyo,Kashiwa, Chiba 277-8583 (Japan); Takimoto, Masahiro [Theory Center, KEK,1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Department of Particle Physics and Astrophysics, Weizmann Institute of Science,Rehovot 7610001 (Israel); Yamada, Masaki [Institute of Cosmology, Department of Physics and Astronomy, Tufts University,Medford, MA 02155 (United States); Department of Physics, Tohoku University,Sendai, Miyagi 980-8578 (Japan)

    2017-03-23

    We study I-balls/oscillons, which are long-lived, quasi-periodic, and spatially localized solutions in real scalar field theories. Contrary to the case of Q-balls, there is no evident conserved charge that stabilizes the localized configuration. Nevertheless, in many classical numerical simulations, it has been shown that they are extremely long-lived. In this paper, we clarify the reason for the longevity, and show how the exponential separation of time scales emerges dynamically. Those solutions are time-periodic with a typical frequency of a mass scale of a scalar field. This observation implies that they can be understood by the effective theory after integrating out relativistic modes. We find that the resulting effective theory has an approximate global U(1) symmetry reflecting an approximate number conservation in the non-relativistic regime. As a result, the profile of those solutions is obtained via the bounce method, just like Q-balls, as long as the breaking of the U(1) symmetry is small enough. We then discuss the decay processes of the I-ball/oscillon by the breaking of the U(1) symmetry, namely the production of relativistic modes via number violating processes. We show that the imaginary part is exponentially suppressed, which explains the extraordinary longevity of I-ball/oscillon. In addition, we find that there are some attractor behaviors during the evolution of I-ball/oscillon that further enhance the lifetime. The validity of our effective theory is confirmed by classical numerical simulations. Our formalism may also be useful to study condensates of ultra light bosonic dark matter, such as fuzzy dark matter, and axion stars, for instance.

  5. CT diagnosis of tumor thrombus of the renal vein and inferior vena cava

    International Nuclear Information System (INIS)

    Masuda, Fujio; Chen, Zuicho; Oishi, Yukihiko; Machida, Toyohei

    1980-01-01

    We used computed tomography (CT) for diagnosis in 4 cases of renal tumor associated with tumor thrombus of the renal vein and inferior vana cava. The results obtained are described below: A total of 4 cases consisting of 3 cases of renal cell carcinoma and one case of squamous cell carcinoma of the renal pelvis, treated at the Jikei University Hospital during the six months period from January to June of 1979, were studied. The affected side was right in 3 cases and left in one case. In all of the former cases the tumor thrombus was extending from the renal vein to the inferior vena cava, while in the latter case it was confined in the renal vein. All these 4 cases received CT together with renal arteriography and inferior venacavography, followed by nephrectomy, and were confirmed of the presence of tumor thrombus in the renal vein and inferior vena cava operatively. CT findings revealed a pronounced enlargement of the renal vein, and tumor thrombus of the renal vein was diagnosed in all of the 4 cases. In 2 of 3 cases in which tumor thrombus extended to the inferior vena cava, the dilated renal vein was found to be connected to the slightly dilated inferior vena cava, while in the remaining one case the outline of the inferior vena cava was obscure, showing no clear dilatation. After contrast enhancement, a filling defect was seen in the inferior vena cava. CT findings of tumor thrombus in the vein indicated a dilatation of the renal vein and inferior vena cava. In addition, a filling defect was found after contrast enhancement, suggesting that CT is helpful as a diagnostic aid. (author)

  6. Soccer ball lift coefficients via trajectory analysis

    International Nuclear Information System (INIS)

    Goff, John Eric; Carre, Matt J

    2010-01-01

    We performed experiments in which a soccer ball was launched from a machine while two high-speed cameras recorded portions of the trajectory. Using the trajectory data and published drag coefficients, we extracted lift coefficients for a soccer ball. We determined lift coefficients for a wide range of spin parameters, including several spin parameters that have not been obtained by today's wind tunnels. Our trajectory analysis technique is not only a valuable tool for professional sports scientists, it is also accessible to students with a background in undergraduate-level classical mechanics.

  7. Soccer ball lift coefficients via trajectory analysis

    Energy Technology Data Exchange (ETDEWEB)

    Goff, John Eric [Department of Physics, Lynchburg College, Lynchburg, VA 24501 (United States); Carre, Matt J, E-mail: goff@lynchburg.ed [Department of Mechanical Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom)

    2010-07-15

    We performed experiments in which a soccer ball was launched from a machine while two high-speed cameras recorded portions of the trajectory. Using the trajectory data and published drag coefficients, we extracted lift coefficients for a soccer ball. We determined lift coefficients for a wide range of spin parameters, including several spin parameters that have not been obtained by today's wind tunnels. Our trajectory analysis technique is not only a valuable tool for professional sports scientists, it is also accessible to students with a background in undergraduate-level classical mechanics.

  8. Radiodiagnostic methods in determining the structure of tumor thrombus in the inferior vena cava in kidney cancer

    Directory of Open Access Journals (Sweden)

    N. B. Vikhrova

    2015-01-01

    Full Text Available Renal cell carcinoma (RCC is the most common primary tumor of the renal parenchyma. Venous involvement is one of the most important anatomic characteristics of tumor. It is known that venous spread influences the survival of patients with RCC. Tumor thrombosis of IVC in patients with renal cell carcinoma has been reported in 4–10 %. The reference standard for RCC with tumor thrombus remains surgical resection. The structure of thrombus determines some technical difficulties in the management of tumor. Spongeous thrombus correlate with higher risk of thrombus detachment during surgery resulting in PE. Therefore determination of IVC thrombus consistency is very important part of preoperative radiologic assessment of tumor in patients with RCC.

  9. From a Ball Game to Incompleteness

    Indian Academy of Sciences (India)

    We present a ball game that can be continued as long as wewish. It looks as though the game would never end. But byapplying a result on trees, we show that the game nonethelessends in some finite number of moves. We then point out somedeep results on the natural number system connected withthe game.

  10. 4 π physics with the plastic ball

    International Nuclear Information System (INIS)

    Gutbrod, H.H.; Loehner, H.; Poskanzer, A.M.; Renner, T.; Riedesel, H.; Ritter, H.G.; Warwick, A.; Weik, F.; Wieman, H.

    1982-10-01

    4 π data taken with the Plastic Ball show that cluster production in relativistic nuclear collisions depends on both the size of the participant volume and the finite size of the cluster. The measurement of the degree of thermalization and the search for collective flow will permit the study of the applicability of macroscopic concepts such as temperature and density

  11. Crystal Ball results on tau decays

    International Nuclear Information System (INIS)

    Lowe, S.T.

    1987-10-01

    This report reviews measurements and upper limit determinations for a number of exclusive 1-prong tau decay modes using the Crystal Ball detector. These results are important input to the apparent discrepancy between the topological and sum-of-exclusive branching fractions in 1-prong tau decays

  12. A plasma ball in the Microcosm museum

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    Plasma balls, like the one shown here, are displayed in the Microcosm exhibition where families can visit to learn more about the experiments carried out in a research institute like CERN. Hands-on activities allow visitors to get a step closer to the research activities carried out at CERN.

  13. Fractal Aggregates in Tennis Ball Systems

    Science.gov (United States)

    Sabin, J.; Bandin, M.; Prieto, G.; Sarmiento, F.

    2009-01-01

    We present a new practical exercise to explain the mechanisms of aggregation of some colloids which are otherwise not easy to understand. We have used tennis balls to simulate, in a visual way, the aggregation of colloids under reaction-limited colloid aggregation (RLCA) and diffusion-limited colloid aggregation (DLCA) regimes. We have used the…

  14. Soccer Ball Production for Nike in Pakistan

    NARCIS (Netherlands)

    K.A. Siegmann (Karin Astrid)

    2008-01-01

    textabstractThis paper looks at how Nike’s soccer ball suppliers (previous and current) in Sialkot (Pakistan) fare in relation to the company’s code of ethics. While minimum required working conditions are implemented, the criteria for social and environmental compliance are not met with. The

  15. When Two Balls Are Just One

    Science.gov (United States)

    Kulp, Christopher W.; Biermann, Mark L.; Howard, Timothy; Klingenberg, Kurtis; Ramsey, Paul

    2008-01-01

    A camcorder can be a powerful tool in pedagogical settings, such as in an introductory physics course or in introducing undergraduates to data collection. In this paper, we discuss our experience using a Panasonic PV-GS150 digital camcorder to analyze the motion of a falling steel ball, with the goal of determining the acceleration due to gravity,…

  16. On the dynamics of ball bearings

    NARCIS (Netherlands)

    Wensing, J.A.

    1998-01-01

    This investigation on the dynamic behaviour of ball bearings was motivated by the demand for silent bearings in noise-sensitive applications, especially in the household appliance and automotive industry. The present investigations are intended to provide a clear understanding of the role of the

  17. Neutrons and the crystal ball experiments

    International Nuclear Information System (INIS)

    Alyea, J.; Grosnick, D.; Koetke, D.; Manweiler, R.; Spinka, H.; Stanislaus, S.

    1997-01-01

    The Crystal Ball detector, as originally constructed, consisted of a set of 672 optically-isolated NaI crystals, forming an approximately spherical shell and each crystal viewed by a photomultiplier, a charged-particle tracker within the NaI shell, and two endcaps to cover angles close to two colliding beams. The detector geometry subtends a solid angle of about 93% of 4π st (20 degree le θ le 160degree and 0degree le φ le 360degree) from the center. The Crystal Ball detector was used for two long series of experiments at the e + e - colliding beam accelerators SPEAR [1, 2, 3, 4] at SLAC and DORIS [5, 6, 7, 8] at DESY. A new set of measurements using the Crystal Ball detector is planned at the Brookhaven National Laboratory Alternating Gradient Synchrotrons (BNL AGS). These new experiments will use the 672 NaI crystals from the original detector, but neither the tracker nor endcaps. The ''Crystal Ball'' in this note will refer only to the set of NaI crystals. Initially, the reactions to be studied will include π - pr a rrow neutrals with pion beam momenta approximately400-750 MeV/c and K - pr a rrow neutrals with kaon beam momenta approximately600-750 MeV/c. Each of these reactions will include a neutron in the final state. whereas the fraction of e + e - interactions with neutrons at SLAC or DESY was quite small. Consequently, there is relatively little experience understanding the behavior of neutrons in the Crystal Ball

  18. Validity and Reliability of a Medicine Ball Explosive Power Test.

    Science.gov (United States)

    Stockbrugger, Barry A.; Haennel, Robert G.

    2001-01-01

    Evaluated the validity and reliability of a medicine ball throw test to evaluate explosive power. Data on competitive sand volleyball players who performed a medicine ball throw and a standard countermovement jump indicated that the medicine ball throw test was a valid and reliable way to assess explosive power for an analogous total-body movement…

  19. Thrombus Development on a Transseptal Sheath in the Right Atrium Before Electrical Pulmonary Vein Isolation

    Directory of Open Access Journals (Sweden)

    Nieves Romero-Rodriguez

    2008-02-01

    Full Text Available We describe the case of a patient who developed a thrombus on the transseptal sheath in the right atrium before transseptal puncture for circumferential pulmonary vein isolation for paroxysmal atrial fibrillation treatment. The use of intracardiac echocardiography allowed to its identification and probably prevented the patient from suffering a serious thromboembolic complication.

  20. Large mobile thrombus in non-atherosclerotic thoracic aorta as the source of peripheral arterial embolism

    Directory of Open Access Journals (Sweden)

    Brkovic Zoran

    2005-11-01

    Full Text Available Abstract The presence of thrombi in the atherosclerotic and/or aneurysmatic aorta with peripheral arterial embolism is a common scenario. Thrombus formation in a morphologically normal aorta, however, is a rare event. A 50 years old woman was admitted to the mergency department for pain, coldness, and anesthesia in the the left foot. She had a 25 years history of cigarette smoking, a history of postmenopausal hormone replacement therapy (HRT, hypercholesterolemia and hyperfibrinogenemia. An extensive serologic survey for hypercoagulability, including antiphospholipid antibodies, and vasculitis disorders was negative. Transesophageal echocardiography revealed a large, pedunculated and hypermobile thrombus attached to the aortic wall 5 cm distal of the left subclavian artery. The patient was admitted to the surgery department, where a 15 cm long fresh, parietal thrombus could be removed from the aorta showing no macroscopic wall lesions or any other morphologic abnormalities. This case report demonstrates the possibility of evolving a large, pedunculated thrombus in a morphologically intact aorta in a postmenopausal woman with thrombogenic conditions such as hyperfibrinogenemia, hypercholesterolemia, smoking and HRT. For these patients, profiling the individual risk and weighing the benefits against the potential risks is warranted before prescribing HRT.

  1. Role of newly formed platelets in thrombus formation in rat after clopidogrel treatment

    DEFF Research Database (Denmark)

    Kuijpers, Marijke J E; Megens, Remco T A; Nikookhesal, Elham

    2011-01-01

    Platelet P2Y₁₂ receptors play an important role in arterial thrombosis by stimulating thrombus growth. Both irreversibly (clopidogrel) and reversibly binding (ticagrelor, AZD6140) P2Y₁₂ antagonists are clinically used for restricted periods, but possible differences in platelet function recovery ...

  2. Saphenous vein graft thrombus findings by scanning electron microscopy in a patient with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Marcela Dias; Aguillera, André Haraguti [Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Brilhante, José Joaquim; Caixeta, Adriano [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2013-07-01

    An eighty-year-old male patient with a history of prior (19 years) coronary artery bypass graft surgery was admitted to the hospital with non ST-segment elevation myocardial infarction (NSTEMI). During the hospital stay he was taking acetylsalicylic acid 100mg per day, a loading dose of 600mg clopidogrel, and low molecular weight heparin 1mg/kg twice a day. Twenty-four hours later the patient underwent coronary angiography, which showed a 90% obstruction in the mid portion of the saphenous vein graft to obtuse marginal with signs of degeneration and local thrombus (Figure 1). Thrombus aspiration was performed with a 6-Fr Export{sup ™} catheter (Medtronic, Santa Rosa, CA, USA), which removed small reddish colored fragments. They were fixed in 2,5% glutaraldehyde in a 0.1M sodium cacodilate buffer. The material was processed following the GOTO protocol in which the fragments were washed with osmium tetroxide and titanic acid, after which they were dried in a critical-point device and a golden bath. Scanning electron microscopy and high definition photos (3,000 to 27,221x magnification) were obtained by the FEI Quanta{sup ™} FEG SEM device (FEI Company, Hillsboro, OR, USA). The images showed that the thrombus was rich in activated platelets, with few erythrocytes or inflammatory cells. Many cholesterol crystals were observed (Figures 2 to). The fibrin networks were sparse and thin, which is compatible with a short ischemic time and recent thrombus formation.

  3. Systematic Review of Treatment for Trapped Thrombus in Patent Foramen Ovale.

    Science.gov (United States)

    Seo, Won-Woo; Kim, Sung Eun; Park, Myung-Soo; Lee, Jun-Hee; Park, Dae-Gyun; Han, Kyoo-Rok; Oh, Dong-Jin

    2017-09-01

    Trapped thrombus in patent foramen ovale (PFO) is a rare complication of pulmonary embolism that may lead to tragic clinical events. The aim of this study was to identify the optimal treatment for different clinical situations in patients with trapped thrombus in a PFO by conducting a literature review. A PubMed database search was conducted from 1991 through 2015, and 194 patients (185 articles) with trapped thrombus in a PFO were identified. Patient characteristics, paradoxical embolic events, and factors affecting 60-day mortality were analyzed retrospectively. Among all patients, 112 (57.7%) were treated with surgery, 28 with thrombolysis, and 54 with anticoagulation alone. Dyspnea (79.4%), chest pain (33.0%), and syncope (17.5%) were the most common presenting symptoms. Pretreatment embolism was found in 37.6% of cases, and stroke (24.7%) was the most common event. Surgery was associated with fewer post-treatment embolic events than were other treatment options (p=0.044). In the multivariate analysis, initial shock or arrest, and thrombolysis were independent predictors of 60-day mortality. Thrombolysis was related with higher 60-day mortality compared with surgery in patients who had no initial shock or arrest. This systematic review showed that surgery was associated with a lower overall incidence of post-treatment embolic events and a lower 60-day mortality in patients with trapped thrombus in a PFO. In patients without initial shock or arrest, thrombolysis was related with a higher 60-day mortality compared with surgery.

  4. CORONARY EMBOLISM WITH FRAGMENTED THROMBUS FROM THE LEFT VENTRICLE IN PATIENT WITH POSTINFARCTION ANEURYSM

    Directory of Open Access Journals (Sweden)

    Yu. F. Salakhova

    2011-01-01

    Full Text Available The thrombus formation in the left ventricle (LV cavity is a frequent complication of myocardial infarction (MI as well as a risk factor for peripheral arterial embolism. Probability of intraventricular thrombus depends on MI location and its therapy. A case of coronary embolism in a patient with anterior MI and thrombus in the LV aneurysm is considered in details. Successful percutaneous coronary intervention (PCI in the first 90 minutes after admission was performed. Decision to appoint a three-component antithrombotic therapy (acetylsalicylic acid, clopidogrel, warfarin was made on the 4th day of disease onset taking into account the combination of MI, stent placement in the anterior interventricular artery and the presence of left ventricular aneurysm with parietal thrombus. Recurrence of MI developed on the 9th day of disease onset. Aspiration thromboembolectomy was performed taking into account thrombosis of two coronary arteries. Warfarin therapy was discontinued in connection with subsequent clot lysis and development of not intensive nosebleed. Subsequent MI course was uneventful. In conclusion, even in spite of the timely achievement of PCI and early reperfusion, MI course can be complicated by thrombosis of the left ventricle and subsequent development of thromboembolic complications.

  5. Greenfield filter caval perforation causing an aortic mural thrombus and femoral artery occlusion.

    Science.gov (United States)

    Chintalapudi, U B; Gutierrez, O H; Azodo, M V

    1997-05-01

    A 32-year-old woman suffered a right femoral artery embolic occlusion from an abdominal aortic mural thrombus associated with caval perforation by a stainless steel Greenfield Filter. The complication required thrombolytic therapy, surgical revascularization, and long-term anticoagulation.

  6. Saphenous vein graft thrombus findings by scanning electron microscopy in a patient with acute myocardial infarction

    International Nuclear Information System (INIS)

    Borges, Marcela Dias; Aguillera, André Haraguti; Brilhante, José Joaquim; Caixeta, Adriano

    2013-01-01

    An eighty-year-old male patient with a history of prior (19 years) coronary artery bypass graft surgery was admitted to the hospital with non ST-segment elevation myocardial infarction (NSTEMI). During the hospital stay he was taking acetylsalicylic acid 100mg per day, a loading dose of 600mg clopidogrel, and low molecular weight heparin 1mg/kg twice a day. Twenty-four hours later the patient underwent coronary angiography, which showed a 90% obstruction in the mid portion of the saphenous vein graft to obtuse marginal with signs of degeneration and local thrombus (Figure 1). Thrombus aspiration was performed with a 6-Fr Export"™ catheter (Medtronic, Santa Rosa, CA, USA), which removed small reddish colored fragments. They were fixed in 2,5% glutaraldehyde in a 0.1M sodium cacodilate buffer. The material was processed following the GOTO protocol in which the fragments were washed with osmium tetroxide and titanic acid, after which they were dried in a critical-point device and a golden bath. Scanning electron microscopy and high definition photos (3,000 to 27,221x magnification) were obtained by the FEI Quanta"™ FEG SEM device (FEI Company, Hillsboro, OR, USA). The images showed that the thrombus was rich in activated platelets, with few erythrocytes or inflammatory cells. Many cholesterol crystals were observed (Figures 2 to). The fibrin networks were sparse and thin, which is compatible with a short ischemic time and recent thrombus formation

  7. Computed tomographic diagnosis of calcified inferior vena cava thrombus in a child with Wilm's tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kirks, D R; Ponzi, J W; Korobkin, M

    1980-01-01

    A calcified thrombus in the inferior vena cava of infants and children may be imaged by computed tomography. The precise location of the calcification within the inferior vena cava may be confirmed by computed tomographic scanning during injection of intravenous contrast material.

  8. Bacterial signatures in thrombus aspirates of patients with lower limb arterial and venous thrombosis.

    Science.gov (United States)

    Vakhitov, Damir; Tuomisto, Sari; Martiskainen, Mika; Korhonen, Janne; Pessi, Tanja; Salenius, Juha-Pekka; Suominen, Velipekka; Lehtimäki, Terho; Karhunen, Pekka J; Oksala, Niku

    2018-06-01

    Increasing data supports the role of bacterial inflammation in adverse events of cardiovascular and cerebrovascular diseases. In our previous research, DNA of bacterial species found in coronary artery thrombus aspirates and ruptured cerebral aneurysms were mostly of endodontic and periodontal origin, where Streptococcus mitis group DNA was the most common. We hypothesized that the genomes of S mitis group could be identified in thrombus aspirates of patients with lower limb arterial and deep venous thrombosis. Thrombus aspirates and control blood samples taken from 42 patients with acute or acute-on-chronic lower limb ischemia (Rutherford I-IIb) owing to arterial or graft thrombosis (n = 31) or lower limb deep venous thrombosis (n = 11) were examined using a quantitative real-time polymerase chain reaction to detect all possible bacterial DNA and DNA of S mitis group in particular. The samples were considered positive, if the amount of bacterial DNA in the thrombus aspirates was 2-fold or greater in comparison with control blood samples. In the positive samples the mean difference for the total bacterial DNA was 12.1-fold (median, 7.1), whereas the differences for S mitis group DNA were a mean of 29.1 and a median of 5.2-fold. Of the arterial thrombus aspirates, 57.9% were positive for bacterial DNA, whereas bacterial genomes were found in 75% of bypass graft thrombosis with 77.8% of the prosthetic grafts being positive. Of the deep vein thrombus aspirates, 45.5% contained bacterial genomes. Most (80%) of bacterial DNA-positive cases contained DNA from the S mitis group. Previous arterial interventions were significantly associated with the occurrence of S mitis group DNA (P = .049, Fisher's exact test). This is the first study to report the presence of bacterial DNA, predominantly of S mitis group origin, in the thrombus aspirates of surgical patients with lower limb arterial and deep venous thrombosis, suggesting their possible role in the pathogenesis of

  9. [Molecular imaging of thrombus with microbubbles targeted to alphavbeta3-integrin using an agarose flow chamber model].

    Science.gov (United States)

    Hu, Guang-quan; Liu, Jian; Yang, Li; Yan, Yi; Wu, Jue-fei; Xie, Jia-jia; Cai, Jing-jing; Ji, Li-jing; Bin, Jian-ping

    2010-03-01

    To assess the binding ability of microbubbles targeted to alphavbeta3-integrin (MBp) for thrombus-targeted contrast-enhanced ultrasound. Targeted microbubbles were prepared by conjugating the monoclonal antibody against alphavbeta3-integrin to lipid shell of the microbubble via the avidin-biotin bridges. Equivalent isotype control microbubbles (MB) or targeted ultrasound microbubbles (MBp) were randomly added into the flow chamber. After a 30-min incubation with the thrombus fixed in an agarose flow chamber model, the thrombus was washed with a continuous flow of PBS solution (15 cm/s) for 2, 4, 6, 8 and 10 min, followed by thrombus imaging using contrast-enhanced ultrasound and measurement of the video intensity (VI) values of the images. The VI of the thrombus in MBp group was reduced by 28%-66%, while that in control MB group was decreased by 87%-94%, and the VI values of the thrombus group were significantly greater in former group at each of the time points (Pevaluation of the thrombus-binding capability of the targeted microbubble (MBp) by simulating the shear stress in vivo can be helpful for predicting the in vivo effects of ultrasonic molecular imaging using MBp.

  10. A Case of Myopathy, Encephalopathy, Lactic Acidosis and Stroke-Like Episodes (MELAS) Syndrome with Intracardiac Thrombus [corrected].

    Science.gov (United States)

    Joo, Jung-Chul; Seol, Myung Do; Yoon, Jin Won; Lee, Young Soo; Kim, Dong-Keun; Choi, Yong Hoon; Ahn, Hyo Seong; Cho, Wook Hyun

    2013-03-01

    Myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) is a multisystem clinical syndrome manifested by mitochondrial myopathy, encephalopathy, lactic acidosis and recurrent stroke-like episodes. A 27-year-old female with MELAS syndrome presented with cerebral infarction. Echocardiography revealed a thrombus attached to the apex of the hypertrophied left ventricle, with decreased systolic function. The embolism of the intracardiac thrombus might have been the cause of stroke. There should be more consideration given to the increased possibility of intracardiac thrombus formation when a MELAS patient with cardiac involvement is encountered.

  11. How does gravity save or kill Q-balls?

    International Nuclear Information System (INIS)

    Tamaki, Takashi; Sakai, Nobuyuki

    2011-01-01

    We explore stability of gravitating Q-balls with potential V 4 (φ)=(m 2 /2)φ 2 -λφ 4 +(φ 6 /M 2 ) via catastrophe theory, as an extension of our previous work on Q-balls with potential V 3 (φ)=(m 2 /2)φ 2 -μφ 3 +λφ 4 . In flat spacetime Q-balls with V 4 in the thick-wall limit are unstable and there is a minimum charge Q min , where Q-balls with Q min are nonexistent. If we take self-gravity into account, on the other hand, there exist stable Q-balls with arbitrarily small charge, no matter how weak gravity is. That is, gravity saves Q-balls with small charge. We also show how stability of Q-balls changes as gravity becomes strong.

  12. Casimir Energies for Isorefractive or Diaphanous Balls

    Directory of Open Access Journals (Sweden)

    Kimball A. Milton

    2018-03-01

    Full Text Available It is known that the Casimir self-energy of a homogeneous dielectric ball is divergent, although a finite self-energy can be extracted through second order in the deviation of the permittivity from the vacuum value. The exception occurs when the speed of light inside the spherical boundary is the same as that outside, so the self-energy of a perfectly conducting spherical shell is finite, as is the energy of a dielectric-diamagnetic sphere with ε μ = 1 , a so-called isorefractive or diaphanous ball. Here we re-examine that example and attempt to extend it to an electromagnetic δ -function sphere, where the electric and magnetic couplings are equal and opposite. Unfortunately, although the energy expression is superficially ultraviolet finite, additional divergences appear that render it difficult to extract a meaningful result in general, but some limited results are presented.

  13. Relative locality and the soccer ball problem

    International Nuclear Information System (INIS)

    Amelino-Camelia, Giovanni; Freidel, Laurent; Smolin, Lee; Kowalski-Glikman, Jerzy

    2011-01-01

    We consider the behavior of macroscopic bodies within the framework of relative locality [G. Amelino-Camelia, L. Freidel, J. Kowalski-Glikman, and L. Smolin, arXiv:1101.0931]. This is a recent proposal for Planck scale modifications of the relativistic dynamics of particles which are described as arising from deformations in the geometry of momentum space. We consider and resolve a common objection against such proposals, which is that, even if the corrections are small for elementary particles in current experiments, they are huge when applied to composite systems such as soccer balls, planets, and stars, with energies E macro much larger than M P . We show that this soccer ball problem does not arise within the framework of relative locality because the nonlinear effects for the dynamics of a composite system with N elementary particles appear at most of order E macro /N·M P .

  14. Ball-thrower's fracture of the humerus

    International Nuclear Information System (INIS)

    Callaghan, Eric B.; Bennett, D. Lee; El-Khoury, Georges Y.; Ohashi, Kenjirou

    2004-01-01

    A relatively rare case of ball-thrower's fracture of the humerus is presented. Severe muscular action is an uncommon cause of humeral fractures but has been well documented in the orthopedic literature. To our knowledge, this fracture has not been described in the radiology literature, and awareness of this entity could preclude further unnecessary workup. The mechanism of injury and its typical radiographic appearance is described. (orig.)

  15. From a Ball Game to Incompleteness

    Indian Academy of Sciences (India)

    tree is a tree in which each node has a finite number of children. In a rooted tree, the sequence of nodes from the root to a leaf, where the (j + 1)th node is a child of the jth node, is called a. 'path'. For instance, in the above tree, the root contains 2, and all leafs are the nodes that contain 0. Since any ball is replaced with a fi-.

  16. CVD carbon powders modified by ball milling

    Directory of Open Access Journals (Sweden)

    Kazmierczak Tomasz

    2015-09-01

    Full Text Available Carbon powders produced using a plasma assisted chemical vapor deposition (CVD methods are an interesting subject of research. One of the most interesting methods of synthesizing these powders is using radio frequency plasma. This method, originally used in deposition of carbon films containing different sp2/sp3 ratios, also makes possible to produce carbon structures in the form of powder. Results of research related to the mechanical modification of these powders have been presented. The powders were modified using a planetary ball mill with varying parameters, such as milling speed, time, ball/powder mass ratio and additional liquids. Changes in morphology and particle sizes were measured using scanning electron microscopy and dynamic light scattering. Phase composition was analyzed using Raman spectroscopy. The influence of individual parameters on the modification outcome was estimated using statistical method. The research proved that the size of obtained powders is mostly influenced by the milling speed and the amount of balls. Powders tend to form conglomerates sized up to hundreds of micrometers. Additionally, it is possible to obtain nanopowders with the size around 100 nm. Furthermore, application of additional liquid, i.e. water in the process reduces the graphitization of the powder, which takes place during dry milling.

  17. 3D Printing of Ball Grid Arrays

    Science.gov (United States)

    Sinha, Shayandev; Hines, Daniel; Dasgupta, Abhijit; Das, Siddhartha

    Ball grid arrays (BGA) are interconnects between an integrated circuit (IC) and a printed circuit board (PCB), that are used for surface mounting electronic components. Typically, lead free alloys are used to make solder balls which, after a reflow process, establish a mechanical and electrical connection between the IC and the PCB. High temperature processing is required for most of these alloys leading to thermal shock causing damage to ICs. For producing flexible circuits on a polymer substrate, there is a requirement for low temperature processing capabilities (around 150 C) and for reducing strain from mechanical stresses. Additive manufacturing techniques can provide an alternative methodology for fabricating BGAs as a direct replacement for standard solder bumped BGAs. We have developed aerosol jet (AJ) printing methods to fabricate a polymer bumped BGA. As a demonstration of the process developed, a daisy chain test chip was polymer bumped using an AJ printed ultra violet (UV) curable polymer ink that was then coated with an AJ printed silver nanoparticle laden ink as a conducting layer printed over the polymer bump. The structure for the balls were achieved by printing the polymer ink using a specific toolpath coupled with in-situ UV curing of the polymer which provided good control over the shape, resulting in well-formed spherical bumps on the order of 200 um wide by 200 um tall for this initial demonstration. A detailed discussion of the AJ printing method and results from accelerated life-time testing will be presented

  18. Relation Between Hertz Stress-Life Exponent, Ball-Race Conformity, and Ball Bearing Life

    Science.gov (United States)

    Zaretsky, Erwin V.; Poplawski, Joseph V.; Root, Lawrence E.

    2008-01-01

    ANSI/ABMA and ISO standards based on Lundberg-Palmgren bearing life theory are normalized for ball bearings having inner- and outerrace conformities of 52 percent (0.52) and made from pre-1940 bearing steel. The Lundberg-Palmgren theory incorporates an inverse 9th power relation between Hertz stress and fatigue life for ball bearings. The effect of race conformity on ball set life independent of race life is not incorporated into the Lundberg-Palmgren theory. In addition, post-1960 vacuum-processed bearing steel exhibits a 12th power relation between Hertz stress and life. The work reported extends the previous work of Zaretsky, Poplawski, and Root to calculate changes in bearing life--that includes the life of the ball set--caused by race conformity, Hertz stress-life exponent, ball bearing type and bearing series. The bearing fatigue life in actual application will usually be equal to or greater than that calculated using the ANSI/ABMA and ISO standards that incorporate the Lundberg-Palmgren theory. The relative fatigue life of an individual race is more sensitive to changes in race conformity for Hertz stress-life exponent n of 12 than where n = 9. However, when the effects are combined to predict actual bearing life for a specified set of conditions and bearing geometry, the predicted life of the bearing will be greater for a value of n = 12 than n = 9.

  19. Acute failure of a St. Jude's prosthetic aortic valve: large pannus formation masked by a small thrombus.

    Science.gov (United States)

    Hurwitz, Seth Eric; Waxman, Daniel; Hecht, Susan

    2009-09-01

    Pannus formation and valve thrombus can cause prosthetic valve failure. The authors report the case of a 50-year-old woman who presented to the emergency room with decompensated heart failure secondary to mechanical valve dysfunction. On two-dimensional and transesophageal echocardiography, the patient had severe aortic stenosis and regurgitation. A thrombus seen on the valve was felt to be the etiology of her prosthetic valve failure. She underwent emergent cardiac surgery for aortic valve replacement. Pathology revealed that although a small thrombus was present, extensive pannus was the underlying mechanism of valve dysfunction. Differentiation between pannus and thrombus may have important clinical implications, but this case illustrates that distinguishing between these entities by echocardiographic and clinical criteria may not be possible.

  20. Placement and retrieval of a Guenther tulip filter in patients with a free floating thrombus in inferior vena cava

    International Nuclear Information System (INIS)

    Seong, Min Hyun; Kim, Young Hwan; Lee, Sang Kwon; Choi, Jin Soo; Kim, Mi Jeong; Koo, Ja Hyun; Kim, Hyoung Tae; Cho, Won Hyun; Seong, Nak Kwan

    2005-01-01

    We wanted to assess the technical feasibility and clinical efficacy of the placement and retrieval of a Guenther Tulip filter for the prevention of fatal pulmonary embolism during the management of patients with a free floating thrombus in their inferior vena ca va (IVC). Six patients having a free floating thrombus in their IVC (three patients with an isolated free floating thrombus in the IVC that resulted from immobilization due to traumatic liver injury or cerebral infarction, two patients with coexisting deep vein thrombosis in the left lower extremity that was caused by May-Thurner syndrome, and one patient with coexisting deep vein thrombosis in the right lower extremity that was due to nephrotic syndrome and immobilization after hip joint replacement) underwent placement and retrieval of a Guenther Tulip filter. The placement of the filter was performed through the right internal jugular vein to prevent the risk of detachment of the thrombus during the procedure. Retrieval of filter was performed after the free floating thrombus of the IVC had disappeared on follow-up CT because of anticoagulation therapy, aspiration thrombectomy or catheter directed Urokinase thrombolysis. The Guenther Tulip filter was successfully placed in the IVC in all six patients and it was retrieved after the management of the free floating thrombus. The mean duration of the placement of the filter was 11 days (range:7-25 days). Two patients underwent placement of an iliac vein stent for the management of May-Thurner syndrome. Detachment of the free floating thrombus in the IVC and the subsequent thrombus entrapment in the filter were documented during aspiration thrombectomy or Urokinase thrombolysis in four patients. Recurrent thrombus didn't occur during the follow-up period (range:3-20 months) in five of the six patients. In one patient, a recurrent thrombus due to the discontinuance of anticoagulation therapy was identified at the filter detachment site of the IVC on the follow

  1. Aerodynamics in the classroom and at the ball park

    Science.gov (United States)

    Cross, Rod

    2012-04-01

    Experiments suitable for classroom projects or demonstrations are described concerning the aerodynamics of polystyrene balls. A light ball with sufficient backspin can curve vertically upward through the air, defying gravity and providing a dramatic visual demonstration of the Magnus effect. A ball projected with backspin can also curve downward with a vertical acceleration greater than that due to gravity if the Magnus force is negative. These effects were investigated by filming the flight of balls projected in an approximately horizontal direction so that the lift and drag forces could be easily measured. The balls were also fitted with artificial raised seams and projected with backspin toward a vertical target in order to measure the sideways deflection over a known horizontal distance. It was found that (a) a ball with a seam on one side can deflect either left or right depending on its launch speed and (b) a ball with a baseball seam can also deflect sideways even when there is no sideways component of the drag or lift forces acting on the ball. Depending on the orientations of the seam and the spin axis, a sideways force on a baseball can arise either if there is rough patch on one side of the ball or if there is a smooth patch. A scuff ball with a rough patch on one side is illegal in baseball. The effect of a smooth patch is a surprising new observation.

  2. Biomechanics of Heading a Soccer Ball: Implications for Player Safety

    Directory of Open Access Journals (Sweden)

    Charles F. Babbs

    2001-01-01

    Full Text Available To better understand the risk and safety of heading a soccer ball, the author created a set of simple mathematical models based upon Newton�s second law of motion to describe the physics of heading. These models describe the player, the ball, the flight of the ball before impact, the motion of the head and ball during impact, and the effects of all of these upon the intensity and the duration of acceleration of the head. The calculated head accelerations were compared to those during presumably safe daily activities of jumping, dancing, and head nodding and also were related to established criteria for serious head injury from the motor vehicle crash literature. The results suggest heading is usually safe but occasionally dangerous, depending on key characteristics of both the player and the ball. Safety is greatly improved when players head the ball with greater effective body mass, which is determined by a player�s size, strength, and technique. Smaller youth players, because of their lesser body mass, are more at risk of potentially dangerous headers than are adults, even when using current youth size balls. Lower ball inflation pressure reduces risk of dangerous head accelerations. Lower pressure balls also have greater “touch” and “playability”, measured in terms of contact time and contact area between foot and ball during a kick. Focus on teaching proper technique, the re-design of age-appropriate balls for young players with reduced weight and inflation pressure, and avoidance of head contact with fast, rising balls kicked at close range can substantially reduce risk of subtle brain injury in players who head soccer balls.

  3. A general theory for ball lightning structure and light output

    Science.gov (United States)

    Morrow, R.

    2018-03-01

    A general theory for free-floating ball lightning is presented which unifies the phantom plasma ball theory involving the production of very little light, with theories for ball lightning involving light output produced by burning particles from the soil. The mechanism for the formation of plasma balls is shown to be quite general, producing very similar plasma balls independent of initial ion densities over four orders of magnitude. All that is required is an excess of positive ions in the initial ball of ions. The central plasma density after 1 s is shown to be the reciprocal of the ion neutralization coefficient for all cases, both analytically and computationally. Further, the plasma region has zero electric field in all cases. Surrounding the plasma ball is a sphere of positive ions moving away from the centre via their own space-charge field; this space-charge field, which is the same in all cases near the plasma ball, drives negative ions and negative particles towards the plasma centre. The connection with burning particle theories is the proposition that the burning particles are highly-charged which is very likely after a lightning strike. Burning negatively charged particles would be driven into the plasma ball region and trapped while any positively charged particles would be driven away. The plasma ball structure is shown to last more than 10 s and the ‘burnout time’ for a typical coal particle (as an example) has been measured at 5-10 s this is comparable with the lifetimes observed for ball lightning. The light output from a few hundred particles is estimated to be ~1 W, a typical output for ball lightning. Finally, suggestions are made for the generation of ball lightning in the laboratory.

  4. Correlation of Acute M1 Middle Cerebral Artery Thrombus Location with Endovascular Treatment Success and Clinical Outcome.

    Science.gov (United States)

    Pavabvash, Seyedmehdi; Taleb, Shayandokht; Majidi, Shahram; Qureshi, Adnan I

    2017-01-01

    The location of the arterial occlusion can help with prognostication and treatment triage of acute stroke patients. We aimed to determine the effects of M1 distance-to-thrombus on angiographic recanalization success rate and clinical outcome following endovascular treatment of acute M1 occlusion. All acute ischemic stroke patients with M1 segment middle cerebral artery (MCA) occlusion on admission CT angiography (CTA) who underwent endovascular treatment were analyzed. The distance between thrombus origin and internal carotid artery (ICA) bifurcation was measured on admission CTA. The modified thrombolysis in cerebral infarction (mTICI) grades 2 b (>50% of distal branch filling) and 3 (complete) were considered as successful recanalization. Favorable outcome was defined by 3-month follow-up modified Rankin scale (mRs) score ≤2. Successful recanalization was achieved in 24 (71%) of 34 consecutive patients included in this study. The M1 distance-to-thrombus was shorter among patients with successful recanalization (5.4 ± 5.4 mm) versus those without (11.3 ± 7.6 mm, p = 0.015). The successful recanalization rate was higher among patients with M1 distance-to-thrombus ≤6 mm (odds ratio: 8, 95% confidence interval: 1.37-46.81, p = 0.023) compared with those with distance-to-thrombus >6 mm. There was no significant correlation between M1 distance-to-thrombus and 3-month mRs (rho: 0.131, p = 0.461); however, the distance-to-thrombus negatively correlated with admission National Institutes of Health Stroke Scale (NIHSS) scores (rho: -0.350, p=0.043). On the other hand, successful recanalization and admission NIHSS score were the only independent predictors of favorable outcome. Shorter distance of M1 thrombus from ICA bifurcation is associated with higher rate of successful recanalization following endovascular treatment.

  5. Correlation of Acute M1 Middle Cerebral Artery Thrombus Location with Endovascular Treatment Success and Clinical Outcome

    Science.gov (United States)

    Pavabvash, Seyedmehdi; Taleb, Shayandokht; Majidi, Shahram; Qureshi, Adnan I.

    2017-01-01

    Purpose The location of the arterial occlusion can help with prognostication and treatment triage of acute stroke patients. We aimed to determine the effects of M1 distance-to-thrombus on angiographic recanalization success rate and clinical outcome following endovascular treatment of acute M1 occlusion. Methods All acute ischemic stroke patients with M1 segment middle cerebral artery (MCA) occlusion on admission CT angiography (CTA) who underwent endovascular treatment were analyzed. The distance between thrombus origin and internal carotid artery (ICA) bifurcation was measured on admission CTA. The modified thrombolysis in cerebral infarction (mTICI) grades 2b (>50% of distal branch filling) and 3 (complete) were considered as successful recanalization. Favorable outcome was defined by 3-month follow-up modified Rankin scale (mRs) score ≤2. Results Successful recanalization was achieved in 24 (71%) of 34 consecutive patients included in this study. The M1 distance-to-thrombus was shorter among patients with successful recanalization (5.4 ± 5.4 mm) versus those without (11.3 ± 7.6 mm, p = 0.015). The successful recanalization rate was higher among patients with M1 distance-to-thrombus ≤6 mm (odds ratio: 8, 95% confidence interval: 1.37–46.81, p = 0.023) compared with those with distance-to-thrombus >6 mm. There was no significant correlation between M1 distance-to-thrombus and 3-month mRs (rho: 0.131, p = 0.461); however, the distance-to-thrombus negatively correlated with admission National Institutes of Health Stroke Scale (NIHSS) scores (rho: −0.350, p=0.043). On the other hand, successful recanalization and admission NIHSS score were the only independent predictors of favorable outcome. Conclusion Shorter distance of M1 thrombus from ICA bifurcation is associated with higher rate of successful recanalization following endovascular treatment. PMID:28243346

  6. Feasibility of the optical imaging of thrombus formation in a rotary blood pump by near-infrared light.

    Science.gov (United States)

    Sakota, Daisuke; Murashige, Tomotaka; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu

    2014-09-01

    Blood coagulation is one of the primary concerns when using mechanical circulatory support devices such as blood pumps. Noninvasive detection and imaging of thrombus formation is useful not only for the development of more hemocompatible devices but also for the management of blood coagulation to avoid risk of infarction. The objective of this study is to investigate the use of near-infrared light for imaging of thrombus formation in a rotary blood pump. The optical properties of a thrombus at wavelengths ranging from 600 to 750 nm were analyzed using a hyperspectral imaging (HSI) system. A specially designed hydrodynamically levitated centrifugal blood pump with a visible bottom area was used. In vitro antithrombogenic testing was conducted five times with the pump using bovine whole blood in which the activated blood clotting time was adjusted to 200 s prior to the experiment. Two halogen lights were used for the light sources. The forward scattering through the pump and backward scattering on the pump bottom area were imaged using the HSI system. HSI showed an increase in forward scattering at wavelengths ranging from 670 to 750 nm in the location of thrombus formation. The time at which the thrombus began to form in the impeller rotating at 2780 rpm could be detected. The spectral difference between the whole blood and the thrombus was utilized to image thrombus formation. The results indicate the feasibility of dynamically detecting and imaging thrombus formation in a rotary blood pump. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Size of the thrombus in acute deep vein thrombosis and the significance of patients' age and sex.

    Science.gov (United States)

    Kierkegaard, A

    1981-01-01

    To determine the significance of patients' age and sex on the size of the thrombus in acute deep vein thrombosis, 420 consecutive phlebograms with acute deep vein thrombosis were studied. A significant correlation between the size of the thrombus and increasing age of the patient as well as the sex of male was noted. It is concluded that older patients and men often are at a high risk of pulmonary embolism at the time of diagnosis.

  8. A floating right heart thrombus in transit across tricuspid valve causing an endocardial friction rub

    Directory of Open Access Journals (Sweden)

    Babu Kanjirakadavath

    2013-07-01

    Full Text Available We report a 42-year-old lady on combined oral contraceptive pills with deep venous thrombosis and mild pulmonary embolism, who developed shock, while being treated with heparin. On auscultation, there was an unexpected loud, superficial, squeaky, triphasic friction rub over the left lower parasternal area. Simultaneous echocardiogram revealed a large serpiginous, freely floating mass in right atrium, prolapsing freely to right ventricular inlet across the tricuspid valve. The endocardial friction rub persisted for about 24 h as long as the thrombus was intracardiac and disappeared when the thrombus disappeared from right heart, occluding the proximal left pulmonary artery. She died due to shock awaiting surgery. We highlight that such a rub in a patient with deep venous thrombosis, though rare, may be an important clue to impending pulmonary embolism.

  9. Multi-parameter assessment of thrombus formation on microspotted arrays of thrombogenic surfaces

    OpenAIRE

    sprotocols

    2014-01-01

    Authors: Susanne de Witt, Frauke Swieringa, Judith Cosemans & Johan Heemskerk ### Abstract Thrombus formation by adhering and aggregating blood platelets is fundamental to hemostasis and is a prerequisite for vascular occlusion in pathological thrombosis. The parallel-plate flow chamber technique has been extensively used to measure platelet adhesion and activation in vitro at arterial or venous flow conditions. Here, we describe the use of brightfield and confocal fluorescence micros...

  10. The model of pulmonary embolism caused by autologous thrombus in rabbits

    OpenAIRE

    Yu-Jiao Ding; Yang Chen

    2017-01-01

    Objective: To establish a model of pulmonary embolism in rabbits by using autologous thrombosis of rabbit ear vein, to study the method of establishing acute pulmonary embolism by using autologous thrombus and to explore the diagnostic value of oxygen partial pressure in acute pulmonary embolism. Methods: Twenty rabbits were randomly divided into normal group (n=5), 7 h group, 24h group, 1 week after model establishment Group. The arterial blood gas analysis was performed on th...

  11. Genetic Analysis of the Role of Protein Kinase Cθ in Platelet Function and Thrombus Formation

    Science.gov (United States)

    Hall, Kellie J.; Harper, Matthew T.; Gilio, Karen; Cosemans, Judith M.; Heemskerk, Johan W. M.; Poole, Alastair W.

    2008-01-01

    Background PKCθ is a novel protein kinase C isozyme, predominately expressed in T cells and platelets. PKCθ−/− T cells exhibit reduced activation and PKCθ−/− mice are resistant to autoimmune disease, making PKCθ an attractive therapeutic target for immune modulation. Collagen is a major agonist for platelets, operating through an immunoreceptor-like signalling pathway from its receptor GPVI. Although it has recently been shown that PKCθ positively regulates outside-in signalling through integrin αIIbβ3 in platelets, the role of PKCθ in GPVI-dependent signalling and functional activation of platelets has not been assessed. Methodology/Principal Findings In the present study we assessed static adhesion, cell spreading, granule secretion, integrin αIIbβ3 activation and platelet aggregation in washed mouse platelets lacking PKCθ. Thrombus formation on a collagen-coated surface was assessed in vitro under flow. PKCθ−/− platelets exhibited reduced static adhesion and filopodia generation on fibrinogen, suggesting that PKCθ positively regulates outside-in signalling, in agreement with a previous report. In contrast, PKCθ−/− platelets also exhibited markedly enhanced GPVI-dependent α-granule secretion, although dense granule secretion was unaffected, suggesting that PKCθ differentially regulates these two granules. Inside-out regulation of αIIbβ3 activation was also enhanced downstream of GPVI stimulation. Although this did not result in increased aggregation, importantly thrombus formation on collagen under high shear (1000 s−1) was enhanced. Conclusions/Significance These data suggest that PKCθ is an important negative regulator of thrombus formation on collagen, potentially mediated by α-granule secretion and αIIbβ3 activation. PKCθ therefore may act to restrict thrombus growth, a finding that has important implications for the development and safe clinical use of PKCθ inhibitors. PMID:18815612

  12. Genetic analysis of the role of protein kinase Ctheta in platelet function and thrombus formation.

    Directory of Open Access Journals (Sweden)

    Kellie J Hall

    2008-09-01

    Full Text Available PKCtheta is a novel protein kinase C isozyme, predominately expressed in T cells and platelets. PKCtheta(-/- T cells exhibit reduced activation and PKCtheta(-/- mice are resistant to autoimmune disease, making PKCtheta an attractive therapeutic target for immune modulation. Collagen is a major agonist for platelets, operating through an immunoreceptor-like signalling pathway from its receptor GPVI. Although it has recently been shown that PKCtheta positively regulates outside-in signalling through integrin alpha(IIbbeta(3 in platelets, the role of PKCtheta in GPVI-dependent signalling and functional activation of platelets has not been assessed.In the present study we assessed static adhesion, cell spreading, granule secretion, integrin alpha(IIbbeta(3 activation and platelet aggregation in washed mouse platelets lacking PKCtheta. Thrombus formation on a collagen-coated surface was assessed in vitro under flow. PKCtheta(-/- platelets exhibited reduced static adhesion and filopodia generation on fibrinogen, suggesting that PKCtheta positively regulates outside-in signalling, in agreement with a previous report. In contrast, PKCtheta(-/- platelets also exhibited markedly enhanced GPVI-dependent alpha-granule secretion, although dense granule secretion was unaffected, suggesting that PKCtheta differentially regulates these two granules. Inside-out regulation of alpha(IIbbeta(3 activation was also enhanced downstream of GPVI stimulation. Although this did not result in increased aggregation, importantly thrombus formation on collagen under high shear (1000 s(-1 was enhanced.These data suggest that PKCtheta is an important negative regulator of thrombus formation on collagen, potentially mediated by alpha-granule secretion and alpha(IIbbeta(3 activation. PKCtheta therefore may act to restrict thrombus growth, a finding that has important implications for the development and safe clinical use of PKCtheta inhibitors.

  13. Infection of a ventricular aneurysm and cardiac mural thrombus. Survival after surgical resection

    International Nuclear Information System (INIS)

    Venezio, F.R.; Thompson, J.E.; Sullivan, H.; Subramanian, R.; Ritzman, P.; Gunnar, R.M.

    1984-01-01

    Infections of cardiac mural thrombi are rare, and because antemortem diagnosis is difficult and antibiotic therapy alone ineffective, the associated mortality has been significant. A patient with gram-negative bacillary infection of a mural thrombus is described. Gallium 67 citrate isotope scanning and two-dimensional echocardiography were helpful adjuncts in establishing the diagnosis. Surgical resection of the infected myocardial tissue and prolonged antimicrobial therapy were necessary for cure

  14. Relationship between Serum Inflammatory Biomarkers and Thrombus Characteristics in Patients with ST Segment Elevation Myocardial Infarction.

    Science.gov (United States)

    Niccoli, Giampaolo; Menozzi, Alberto; Capodanno, Davide; Trani, Carlo; Sirbu, Vasile; Fineschi, Massimo; Zara, Chiara; Crea, Filippo; Trabattoni, Daniela; Saia, Francesco; Ladich, Elena; Biondi Zoccai, Giuseppe; Attizzani, Guilherme; Guagliumi, Giulio

    2017-01-01

    To compare angiographic and optical coherence tomography (OCT) data pertinent to thrombi, along with the histologic characteristics of aspirated thrombi in patients presenting with ST elevation myocardial infarction (STEMI) with or without inflammation, as assessed by C-reactive protein (CRP) and myeloperoxidase (MPO). In the OCTAVIA (Optical Coherence Tomography Assessment of Gender Diversity in Primary Angioplasty) study, 140 patients with STEMI referred for primary percutaneous intervention were enrolled. The patients underwent OCT assessment of the culprit vessel, along with blood sampling of CRP and MPO, and histologic analysis of the thrombus. Biomarkers were available for 129 patients, and histology and immunohistochemistry of the thrombi were available for 78 patients. Comparisons were made using the median thresholds of CRP and MPO (2.08 mg/L and 604.124 ng/mL, respectively). There was no correlation between CRP and MPO levels in the whole population (p = 0.685). Patients with high CRP levels had higher thrombus grades and more frequent TIMI flow 0/1 compared with those with low CRP levels (5 [1st quartile 3; 3rd quartile 5] vs. 3.5 mg/L [1; 5], p = 0.007, and 69.3 vs. 48.5%, p = 0.04, respectively). Patients with high MPO levels more commonly had early thrombi than had those with low MPO levels (42.5 vs. 20.0%, p = 0.04). CRP and MPO were not correlated in STEMI patients, possibly reflecting different pathogenic mechanisms, with CRP more related to thrombus burden and MPO to thrombus age. © 2016 S. Karger AG, Basel.

  15. White Thrombus Formation in Blood Tubing Lines in a Chronic Hemodialysis Unit

    OpenAIRE

    Watnick, Suzanne; Stooksbury, Michael; Winter, Rolf; Riscoe, Michael; Cohen, David M.

    2008-01-01

    Background and objectives: Previous reports have described white particulate matter in banked blood components, but no prior public reports describe such matter in blood tubing during the course of routine in-center hemodialysis. This report describes the events, investigations, and preliminary conclusions associated with the spontaneous formation of adherent white thrombus in the venous and arterial blood lines during routine in-center hemodialysis treatments.

  16. Renal Angiomyolipoma with Fatty Thrombus Extending to the Right Atrium: An Exceptional Presentation

    Directory of Open Access Journals (Sweden)

    Yassine Nouira

    2013-01-01

    Full Text Available This paper reports the case of 34-year-old woman who presented with bilateral renal angiomyolipomas (AMLs. On the right side, there was a large AML with a fatty thrombus extending to the right atrium. The treatment consisted of right nephrectomy and complete thrombectomy with extracorporeal circulation and right atriotomy. Postoperatively, the patient was septic and died on postoperative day 7 because of septic shock.

  17. Mucormycosis (Mucor fungus ball) of the maxillary sinus.

    Science.gov (United States)

    Cho, Hang Sun; Yang, Hoon Shik; Kim, Kyung Soo

    2014-01-01

    A fungus ball is an extramucosal fungal proliferation that completely fills one or more paranasal sinuses and usually occurs as a unilateral infection. It is mainly caused by Aspergillus spp in an immunocompetent host, but some cases of paranasal fungal balls reportedly have been caused by Mucor spp. A Mucor fungus ball is usually found in the maxillary sinus and/or the sphenoid sinus and may be black in color. Patients with mucormycosis, or a Mucor fungal ball infection, usually present with facial pain or headache. On computed tomography, there are no pathognomonic findings that are conclusive for a diagnosis of mucormycosis. In this article we report a case of mucormycosis in a 56-year-old woman and provide a comprehensive review of the literature on the "Mucor fungus ball." To the best of our knowledge, 5 case reports (8 patients) have been published in which the fungus ball was thought to be caused by Mucor spp.

  18. Micro structrual characterization and analysis of ball milled silicon carbide

    Science.gov (United States)

    Madhusudan, B. M.; Raju, H. P.; Ghanaraja., S.

    2018-04-01

    Mechanical alloying has been one of the prominent methods of powder synthesis technique in solid state involving cyclic deformation, cold welding and fracturing of powder particles. Powder particles in this method are subjected to greater mechanical deformation due to the impact of ball-powder-ball and ball-powder-container collisions that occurs during mechanical alloying. Strain hardening and fracture of particles decreases the size of the particles and creates new surfaces. The objective of this Present work is to use ball milling of SiC powder for different duration of 5, 10, 15 and 20 hours by High energy planetary ball milling machine and to evaluate the effect of ball milling on SiC powder. Micro structural Studies using Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD) and EDAX has been investigated.

  19. Use of an anti-platelet monoclonal antibody F (ab')2 fragment for imaging thrombus

    International Nuclear Information System (INIS)

    Loutfi, I.; Stuttle, A.W.J.; Peters, A.M.; George, P.; Lavender, J.P.; Lumley, P.

    1990-01-01

    Ten patients with suspected thrombus have been studied using 111 In-labelled F (ab')2 fragments of P256, a monoclonal antibody which recognizes an epitope on the platelet membrane glycoprotein IIb/IIIa complex. The F (ab')2 fragment was radiolabelled with 111 In via diethylenetri-aminepentamacetic acid to give a specific activity of up to 190 MBq (5mCi) mg - 1 without impairment of immunoreactivity. In vitro platelet aggregation studies showed that the F (ab')2 fragment caused less platelet aggregation than the whole antibody on a molar ratio and was without significant effect upon the sensitivity of platelets to a range of aggregating agents. Platalets were labelled in ten patients by intravenous injection of approximately 100 μg P256 F (ab')2. Of the ten patients studies, six showed localization of activity consistent with platelet accumulation. Localization was clearly seen when associated with thrombus of the lower limbs (three patients: deep vein thrombosis; one patient: aortofemoral graft), and was apparent although less marked in two other cases, one of aortic aneurysm and one of carotid stenosis. Use of radiolabelled P256 F (ab')2 offers a means of non-invasive detection of thrombus which, from in vitro studies, would appear to have less direct effect of platelet behaviour than the whole antibody. (author). 9 refs. 8 figs. 1 tab

  20. Functional divergence of platelet protein kinase C (PKC) isoforms in thrombus formation on collagen.

    Science.gov (United States)

    Gilio, Karen; Harper, Matthew T; Cosemans, Judith M E M; Konopatskaya, Olga; Munnix, Imke C A; Prinzen, Lenneke; Leitges, Michael; Liu, Qinghang; Molkentin, Jeffery D; Heemskerk, Johan W M; Poole, Alastair W

    2010-07-23

    Arterial thrombosis, a major cause of myocardial infarction and stroke, is initiated by activation of blood platelets by subendothelial collagen. The protein kinase C (PKC) family centrally regulates platelet activation, and it is becoming clear that the individual PKC isoforms play distinct roles, some of which oppose each other. Here, for the first time, we address all four of the major platelet-expressed PKC isoforms, determining their comparative roles in regulating platelet adhesion to collagen and their subsequent activation under physiological flow conditions. Using mouse gene knock-out and pharmacological approaches in human platelets, we show that collagen-dependent alpha-granule secretion and thrombus formation are mediated by the conventional PKC isoforms, PKCalpha and PKCbeta, whereas the novel isoform, PKC, negatively regulates these events. PKCdelta also negatively regulates thrombus formation but not alpha-granule secretion. In addition, we demonstrate for the first time that individual PKC isoforms differentially regulate platelet calcium signaling and exposure of phosphatidylserine under flow. Although platelet deficient in PKCalpha or PKCbeta showed reduced calcium signaling and phosphatidylserine exposure, these responses were enhanced in the absence of PKC. In summary therefore, this direct comparison between individual subtypes of PKC, by standardized methodology under flow conditions, reveals that the four major PKCs expressed in platelets play distinct non-redundant roles, where conventional PKCs promote and novel PKCs inhibit thrombus formation on collagen.

  1. Functional Divergence of Platelet Protein Kinase C (PKC) Isoforms in Thrombus Formation on Collagen*

    Science.gov (United States)

    Gilio, Karen; Harper, Matthew T.; Cosemans, Judith M. E. M.; Konopatskaya, Olga; Munnix, Imke C. A.; Prinzen, Lenneke; Leitges, Michael; Liu, Qinghang; Molkentin, Jeffery D.; Heemskerk, Johan W. M.; Poole, Alastair W.

    2010-01-01

    Arterial thrombosis, a major cause of myocardial infarction and stroke, is initiated by activation of blood platelets by subendothelial collagen. The protein kinase C (PKC) family centrally regulates platelet activation, and it is becoming clear that the individual PKC isoforms play distinct roles, some of which oppose each other. Here, for the first time, we address all four of the major platelet-expressed PKC isoforms, determining their comparative roles in regulating platelet adhesion to collagen and their subsequent activation under physiological flow conditions. Using mouse gene knock-out and pharmacological approaches in human platelets, we show that collagen-dependent α-granule secretion and thrombus formation are mediated by the conventional PKC isoforms, PKCα and PKCβ, whereas the novel isoform, PKCθ, negatively regulates these events. PKCδ also negatively regulates thrombus formation but not α-granule secretion. In addition, we demonstrate for the first time that individual PKC isoforms differentially regulate platelet calcium signaling and exposure of phosphatidylserine under flow. Although platelet deficient in PKCα or PKCβ showed reduced calcium signaling and phosphatidylserine exposure, these responses were enhanced in the absence of PKCθ. In summary therefore, this direct comparison between individual subtypes of PKC, by standardized methodology under flow conditions, reveals that the four major PKCs expressed in platelets play distinct non-redundant roles, where conventional PKCs promote and novel PKCs inhibit thrombus formation on collagen. PMID:20479008

  2. Cathepsin G-dependent modulation of platelet thrombus formation in vivo by blood neutrophils.

    Directory of Open Access Journals (Sweden)

    Nauder Faraday

    Full Text Available Neutrophils are consistently associated with arterial thrombotic morbidity in human clinical studies but the causal basis for this association is unclear. We tested the hypothesis that neutrophils modulate platelet activation and thrombus formation in vivo in a cathepsin G-dependent manner. Neutrophils enhanced aggregation of human platelets in vitro in dose-dependent fashion and this effect was diminished by pharmacologic inhibition of cathepsin G activity and knockdown of cathepsin G expression. Tail bleeding time in the mouse was prolonged by a cathepsin G inhibitor and in cathepsin G knockout mice, and formation of neutrophil-platelet conjugates in blood that was shed from transected tails was reduced in the absence of cathepsin G. Bleeding time was highly correlated with blood neutrophil count in wildtype but not cathepsin G deficient mice. In the presence of elevated blood neutrophil counts, the anti-thrombotic effect of cathepsin G inhibition was greater than that of aspirin and additive to it when administered in combination. Both pharmacologic inhibition of cathepsin G and its congenital absence prolonged the time for platelet thrombus to form in ferric chloride-injured mouse mesenteric arterioles. In a vaso-occlusive model of ischemic stroke, inhibition of cathepsin G and its congenital absence improved cerebral blood flow, reduced histologic brain injury, and improved neurobehavioral outcome. These experiments demonstrate that neutrophil cathepsin G is a physiologic modulator of platelet thrombus formation in vivo and has potential as a target for novel anti-thrombotic therapies.

  3. Clinical application of endovascular stent-graft in the treatment of portal stenosis of cancerous thrombus

    International Nuclear Information System (INIS)

    Jiang Zaibo; Huang Mingsheng; Wang Jing; Li Zhengran; Qian Jiesheng; Guang Shouhai; Zhu Kangshun; Shan Hong; Zhang Xiongjun

    2007-01-01

    Objective: To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Methods: Six cases with portal vein stenosis of cancerous thrombus, which caused by primary hepatic carcinoma (5 cases) and cholangiocarcinoma (1 case) and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded, were performed percutaneous transhepatic or transsplenic portography. FLUENCY TM endovascular stent-graft (10 mm diameter) was placed at the position of stenosis after gastroesophageal varices embolization. Portal pressure was measured pre- and post-deployment. Results: Stents were successfully placed in all patients. The average portal pressure decreased from 50.7 em H 2 O (1 cm H 2 O0.098 kPa) to 41.3 cm H 2 O after endovascular stent-graft deployment. The restenosis were found in 2 cases after one month. Haematemesis and refractory ascites appeared in one case respectively, the other 4 cases showed no significant symptoms above caused by portal hypertension. Conclusion: It is safe and feasible for endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Selecting the suitable indications, the symptoms of portal hypertension can be controlled effectively. (authors)

  4. Nicorandil prevents sirolimus-induced production of reactive oxygen species, endothelial dysfunction, and thrombus formation

    Directory of Open Access Journals (Sweden)

    Ken Aizawa

    2015-03-01

    Full Text Available Sirolimus (SRL is widely used to prevent restenosis after percutaneous coronary intervention. However, its beneficial effect is hampered by complications of thrombosis. Several studies imply that reactive oxygen species (ROS play a critical role in endothelial dysfunction and thrombus formation. The present study investigated the protective effect of nicorandil (NIC, an anti-angina agent, on SRL-associated thrombosis. In human coronary artery endothelial cells (HCAECs, SRL stimulated ROS production, which was prevented by co-treatment with NIC. The preventive effect of NIC on ROS was abolished by 5-hydroxydecanoate but not by 1H-[1,2,4]oxadiazolo[4,3-a]quinoxalin-1-one. NIC also inhibited SRL-induced up-regulation of NADPH oxidase subunit p22phox mRNA. Co-treatment with NIC and SRL significantly up-regulated superoxide dismutase 2. NIC treatment significantly improved SRL-induced decrease in viability of HCAECs. The functional relevance of the preventive effects of NIC on SRL-induced ROS production and impairment of endothelial viability was investigated in a mouse model of thrombosis. Pretreatment with NIC inhibited the SRL-induced acceleration of FeCl3-initiated thrombus formation and ROS production in the testicular arteries of mice. In conclusion, NIC prevented SRL-induced thrombus formation, presumably due to the reduction of ROS and to endothelial protection. The therapeutic efficacy of NIC could represent an additional option in the prevention of SRL-related thrombosis.

  5. Synthesis of PEGylated polyglutamic acid peptide dendrimer and its application in dissolving thrombus.

    Science.gov (United States)

    Zhang, Shao-Fei; Gao, Chunmei; Lü, Shaoyu; He, Jiujun; Liu, Mingzhu; Wu, Can; Liu, Yijing; Zhang, Xinyu; Liu, Zhen

    2017-11-01

    Nattokinase (NK) has been used as a new generation thrombolytic drug, due to its high safety, low cost and low side effects. However, it is sensitive to external environment and may lose the enzyme activity easily. Peptide dendrimer possesses functional groups on its surface, adjustable sizes, biodegradability, biocompatibility, and low toxicity, which could be used as ideal carrier for drug protection and delivery. Demonstrated for the first time in this paper, a PEGylated dendrimer (G n -PEG-G n ) composed of polyglutamic acid is designed and synthesized as delivery platform of NK for thrombus treatment. A panel of PEGylated dendrimers with three different generations of 2, 3, 4 was prepared to investigate the effect of dendrimer architecture on the properties and therapeutic efficacy of the resultant NK-loaded delivery systems in terms of the morphology, dimension and enzyme activity. The results demonstrated that the NK-loaded G 3 -PEG-G 3 (G 3 -PEG-G 3 /NK ratio of 6/1), of all the formulations, displayed the optimal enzyme activity for dissolving thrombus in vitro, thus offering great potential for the treatment of thrombus. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Retrievable Vena Cava Filters in Major Trauma Patients: Prevalence of Thrombus Within the Filter

    International Nuclear Information System (INIS)

    Mahrer, Arie; Zippel, Douglas; Garniek, Alexander; Golan, Gil; Bensaid, Paul; Simon, Daniel; Rimon, Uri

    2008-01-01

    The purpose of this study was to report the prevalence of thrombus within a retrievable vena cava filter inserted prophylactically in major trauma patients referred for filter extraction. Between November 2002 and August 2005, 80 retrievable inferior vena cava filters (68 Optease and 12 Gunther-Tulip) were inserted into critically injured trauma patients (mean injury severity score 33.5). The filters were inserted within 1 to 6 (mean 2) days of injury. Thirty-seven patients were referred for filter removal (32 with Optease and 5 with Gunther-Tulip). The indwelling time was 7 to 22 (mean 13) days. All patients underwent inferior vena cavography prior to filter removal. There were no insertion-related complications and all filters were successfully deployed. Forty-three (54%) of the 80 patients were not referred for filter removal, as these patients continued to have contraindications to anticoagulation. Thirty-seven patients (46%) were referred for filter removal. In eight of them (22%) a large thrombus was seen within the filters and they were left in place, all with the Optease device. The other 29 filters (36%) were removed uneventfully.We conclude that the relatively high prevalence of intrafilter thrombi with the Optease filter may be explained by either spontaneous thrombus formation or captured emboli.

  7. LOW COMPRESSION TENNIS BALLS AND SKILL DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    John Hammond

    2006-12-01

    Full Text Available Coaching aims to improve player performance and coaches have a number of coaching methods and strategies they use to enhance this process. If new methods and ideas can be determined to improve player performance they will change coaching practices and processes. This study investigated the effects of using low compression balls (LCBs during coaching sessions with beginning tennis players. In order to assess the effectiveness of LCBs on skill learning the study employed a quasi-experimental design supported by qualitative and descriptive data. Beginner tennis players took part in coaching sessions, one group using the LCBs while the other group used standard tennis balls. Both groups were administered a skills at the beginning of a series of coaching sessions and again at the end. A statistical investigation of the difference between pre and post-test results was carried out to determine the effect of LCBs on skill learning. Additional qualitative data was obtained through interviews, video capture and the use of performance analysis of typical coaching sessions for each group. The skill test results indicated no difference in skill learning when comparing beginners using the LCBs to those using the standard balls. Coaches reported that the LCBs appeared to have a positive effect on technique development, including aspects of technique that are related to improving power of the shot. Additional benefits were that rallies went on longer and more opportunity for positive reinforcement. In order to provide a more conclusive answer to the effects of LCBs on skill learning and technique development recommendations for future research were established including a more controlled experimental environment and larger sample sizes across a longer period of time

  8. The methodology of composing the exercises system with fit balls.

    Directory of Open Access Journals (Sweden)

    Voronov N.P.

    2011-02-01

    Full Text Available The original methodology of composing the exercises system with fit balls was considered. More than 10 publications were analysed. On the lesson with fit balls the problem was revealed. In the experiment took part 30 students at the age from 18 till 21. All the famous exercises were systematized. As a result, a big attractiveness and assimilability of the proposed complex was revealed. The effectiveness of the complex of physical exercises with fit balls for students was proved.

  9. Random power series in the unit ball of Cn

    International Nuclear Information System (INIS)

    Shi Jihuai.

    1989-07-01

    The random power series in the unit disc has been studied by many authors. In this paper, we studied the random power series in the unit ball of C n and generalized some results in the unit disc to the unit ball, in particular, the result obtained recently by Duren has been generalized to the unit ball. The main tool used here is the generalized Salem-Zygmund's theorem. (author). 12 refs

  10. Amebiasis in four ball pythons, Python reginus.

    Science.gov (United States)

    Kojimoto, A; Uchida, K; Horii, Y; Okumura, S; Yamaguch, R; Tateyama, S

    2001-12-01

    Between September 13th and November 18th in 1999, four ball pythons, Python reginus kept in the same display, showed anorexia and died one after another. At necropsy, all four snakes had severe hemorrhagic colitis. Microscopically, all snakes had severe necrotizing hemorrhagic colitis, in association with ameba-like protozoa. Some of the protozoa had macrophage-like morphology and others formed protozoal cysts with thickened walls. These protozoa were distributed throughout the wall in the large intestine. Based on the pathological findings, these snakes were infested with a member of Entamoeba sp., presumably with infection by Entamoeba invadens, the most prevalent type of reptilian amoebae.

  11. Collective flow measured with the Plastic Ball

    International Nuclear Information System (INIS)

    Ritter, H.G.; Gutbrod, H.H.; Kampert, K.H.; Kolb, B.; Poskanzer, A.M.; Schicker, R.; Schmidt, H.R.; Siemiarczuk, T.

    1989-08-01

    The experimental results from the Plastic Ball detector have contributed vastly to the understanding of the reaction mechanism of nuclear collisions at several hundred MeV per nucleon. The discovery of the collective flow phenomena (bounce-off of spectator fragments, side-splash in the reaction plane, and squeeze-out out of the reaction plane), as they were predicted by hydrodynamical models, has led to the experimental observation of compressed nuclear matter, which is a necessary condition before one can study the equation of state in detail and search for phase transitions at higher energies. 39 refs., 9 figs., 1 tab

  12. A proposed experiment on ball lightning model

    International Nuclear Information System (INIS)

    Ignatovich, Vladimir K.; Ignatovich, Filipp V.

    2011-01-01

    Highlights: → We propose to put a glass sphere inside an excited gas. → Then to put a light ray inside the glass in a whispering gallery mode. → If the light is resonant to gas excitation, it will be amplified at every reflection. → In ms time the light in the glass will be amplified, and will melt the glass. → A liquid shell kept integer by electrostriction forces is the ball lightning model. -- Abstract: We propose an experiment for strong light amplification at multiple total reflections from active gaseous media.

  13. Quenching simulation of steel grinding balls

    Energy Technology Data Exchange (ETDEWEB)

    Zapata-Hernandez, O.; Reyes, L. A.; Camurri, C.; Carrasco, C.; Garza-Monte-de-Oca, F.; Colas, R.

    2015-07-01

    The phase transformations of high carbon steel during quenching and equalizing were modelled using commercial computer packages based on the finite element method and the kinetic transformation of steel. The model was used to predict the temperature and microstructural changes taking place within balls of two different sizes that are used for grinding mineral ores. A good correlation between the temperatures measured by inserted thermocouples and those predicted by the model was obtained after modifying the thermal conductivity of the steel within the temperature domain at which mixed phases are present. The phase transformations predicted were confirmed by metallographic analyses. (Author)

  14. Crystal Ball evidence for new states

    International Nuclear Information System (INIS)

    Coyne, D.G.

    1981-09-01

    Evidence for three new particles observed in the Crystal Ball detector is presented. The first particle, at 3592 MeV, is seen inclusively in γ transitions from psi', and is thus a candidate for eta/sub c/'. The other two, at 1440 and 1640 MeV, are best seen in exclusive decays of psi involving a prompt γ, and are thus candidates for bound states of two gluons. Detailed reasons are presented to support the contention that these states are distinct from previously observed candidates such as E(1420). Alternative hypotheses are discussed

  15. Results on charmonium from the Crystal Ball

    CERN Document Server

    Partridge, R; Bloom, Elliott D; Bulos, F; Burnett, T; Cavalli-Sforza, M; Chestnut, R; Coyne, D; Gaiser, J; Godfrey, G; Hofstadter, R; Kiesling, C; Kirkbride, I; Kolanoski, H; Kollmann, W; Liberman, A; O'Reilly, J; Oreglia, M J; Peck, C; Porter, F; Richardson, M; Sadrozinski, H F W; Strauch, K; Tompkins, J; Wacker, K

    1979-01-01

    Results from the Crystal Ball experiment at SPEAR are presented. A preliminary analysis of the 3 photon final state from the J/ psi (3095) and of the cascade decays of the psi '(3684) yield new upper limits on the controversial states X(2820), chi (3455) and the even C- parity state at 3.59 GeV. From inclusive gamma -ray spectra of the J/ psi and psi ' preliminary branching ratios for psi ' to chi states and upper limits for J/ psi , psi ' to eta /sub c/, eta /sub c/' are given. (15 refs).

  16. Ball Bearing Analysis with the ORBIS Tool

    Science.gov (United States)

    Halpin, Jacob D.

    2016-01-01

    Ball bearing design is critical to the success of aerospace mechanisms. Key bearing performance parameters, such as load capability, stiffness, torque, and life all depend on accurate determination of the internal load distribution. Hence, a good analytical bearing tool that provides both comprehensive capabilities and reliable results becomes a significant asset to the engineer. This paper introduces the ORBIS bearing tool. A discussion of key modeling assumptions and a technical overview is provided. Numerous validation studies and case studies using the ORBIS tool are presented. All results suggest the ORBIS code closely correlates to predictions on bearing internal load distributions, stiffness, deflection and stresses.

  17. Simulation of ball motion and energy transfer in a planetary ball mill

    International Nuclear Information System (INIS)

    Lu Sheng-Yong; Mao Qiong-Jing; Li Xiao-Dong; Yan Jian-Hua; Peng Zheng

    2012-01-01

    A kinetic model is proposed for simulating the trajectory of a single milling ball in a planetary ball mill, and a model is also proposed for simulating the local energy transfer during the ball milling process under no-slip conditions. Based on the kinematics of ball motion, the collision frequency and power are described, and the normal impact forces and effective power are derived from analyses of collision geometry. The Hertzian impact theory is applied to formulate these models after having established some relationships among the geometric, dynamic, and thermophysical parameters. Simulation is carried out based on two models, and the effects of the rotation velocity of the planetary disk Ω and the vial-to-disk speed ratio ω/Ω on other kinetic parameters is investigated. As a result, the optimal ratio ω/Ω to obtain high impact energy in the standard operating condition at Ω = 800 rpm is estimated, and is equal to 1.15. (interdisciplinary physics and related areas of science and technology)

  18. Respiratory disease in ball pythons (Python regius) experimentally infected with ball python nidovirus.

    Science.gov (United States)

    Hoon-Hanks, Laura L; Layton, Marylee L; Ossiboff, Robert J; Parker, John S L; Dubovi, Edward J; Stenglein, Mark D

    2018-04-01

    Circumstantial evidence has linked a new group of nidoviruses with respiratory disease in pythons, lizards, and cattle. We conducted experimental infections in ball pythons (Python regius) to test the hypothesis that ball python nidovirus (BPNV) infection results in respiratory disease. Three ball pythons were inoculated orally and intratracheally with cell culture isolated BPNV and two were sham inoculated. Antemortem choanal, oroesophageal, and cloacal swabs and postmortem tissues of infected snakes were positive for viral RNA, protein, and infectious virus by qRT-PCR, immunohistochemistry, western blot and virus isolation. Clinical signs included oral mucosal reddening, abundant mucus secretions, open-mouthed breathing, and anorexia. Histologic lesions included chronic-active mucinous rhinitis, stomatitis, tracheitis, esophagitis and proliferative interstitial pneumonia. Control snakes remained negative and free of clinical signs throughout the experiment. Our findings establish a causal relationship between nidovirus infection and respiratory disease in ball pythons and shed light on disease progression and transmission. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  19. CFD Analysis of Swing of Cricket Ball and Trajectory Prediction

    Science.gov (United States)

    G, Jithin; Tom, Josin; Ruishikesh, Kamat; Jose, Jyothish; Kumar, Sanjay

    2013-11-01

    This work aims to understand the aerodynamics associated with the flight and swing of a cricket ball and predict its flight trajectory over the course of the game: at start (smooth ball) and as the game progresses (rough ball). Asymmetric airflow over the ball due to seam orientation and surface roughness can cause flight deviation (swing). The values of Drag, Lift and Side forces which are crucial for determining the trajectory of the ball were found with the help of FLUENT using the standard K- ɛ model. Analysis was done to study how the ball velocity, spin imparted to be ball and the tilt of the seam affects the movement of the ball through air. The governing force balance equations in 3 dimensions in combination a MATLAB code which used Heun's method was used for obtaining the trajectory of the ball. The conditions for the conventional swing and reverse swing to occur were deduced from the analysis and found to be in alignment with the real life situation. Critical seam angle for maximum swing and transition speed for normal to reverse swing were found out. The obtained trajectories were compared to real life hawk eye trajectories for validation. The analysis results were in good agreement with the real life situation.

  20. Two Balls' Collision of Mass Ratio 3:1

    Science.gov (United States)

    Ogawara, Yasuo; Hull, Michael M.

    2018-04-01

    Students will sometimes ask why momentum and kinetic energy concepts are both necessary. When physics teachers demonstrate situations that require both an understanding of kinetic energy and momentum, a favorite is Newton's cradle, or a comparable demonstration of two balls of equal mass hitting each other. However, in addition to the case of two balls of equal mass, if a ball hits another ball of three times the mass with equal speed, the results are also interesting, and, like the equal-mass demonstration, both kinetic energy and momentum are critical for understanding the motion.

  1. An early record of ball lightning: Oliva (Spain), 1619

    Science.gov (United States)

    Domínguez-Castro, Fernando

    2018-05-01

    In a primary documentary source we found an early record of ball lightning (BL), which was observed in the monastery of Pi (Oliva, southeastern Spain) on 18 October 1619. The ball lightning was observed by at least three people and was described as a rolling burning vessel and a ball of fire. The ball lightning appeared following a lightning flash, showed a mainly horizontal motion, crossed a wall, smudged an image of the Lady of Rebollet (then known as Lady of Pi) and burnt her ruff, and overturned a cross.

  2. How does gravity save or kill Q-balls?

    OpenAIRE

    Tamaki, Takashi; Sakai, Nobuyuki

    2011-01-01

    We explore stability of gravitating Q-balls with potential $V_4(\\phi)={m^2\\over2}\\phi^2-\\lambda\\phi^4+\\frac{\\phi^6}{M^2}$ via catastrophe theory, as an extension of our previous work on Q-balls with potential $V_3(\\phi)={m^2\\over2}\\phi^2-\\mu\\phi^3+\\lambda\\phi^4$. In flat spacetime Q-balls with $V_4$ in the thick-wall limit are unstable and there is a minimum charge $Q_{{\\rm min}}$, where Q-balls with $Q

  3. A Left Main Coronary Artery Thrombus Presenting as a Non St Elevation MI.

    Science.gov (United States)

    Ezema, U; Daberkow, D; Delord, T; Guidry, L; Sells, N R

    2017-01-01

    Left main coronary artery (LMCA); thrombus with an acute myocardial infarction identified with coronary angiography is a clinically rare condition with an extremely high mortality rate. We present a case of LMCA thrombus that presented as a non-ST elevation myocardial infarction (NSTEMI);. A 45-year-old woman with a history of tobacco use and hyperlipidemia presented with a complaint of 10/10 "hard pain" across her chest radiating to her left shoulder and breast which woke her from sleep. The pain was constant and severe, with no alleviation with rest. She had not experienced anything like this before. Workup revealed an upward trending troponin (1.98.989.79);, and an EKG with some tachycardia but no ST elevation or T wave changes. Her CBC, CMP and coagulation studies were unremarkable. A toxicology screen was positive for opiates and benzodiazepines, medications she was on for pain and anxiety respectively. ACS protocol was started with DAPT, LMWH, Statin, ACEi, and Beta-blocker. An angiogram revealed a large thrombus in the LM coronary artery extending into the aorta with concomitant 99 percent stenosis of distal LAD. 2D Echo w/ bubble contrast was significant for PFO, akinetic apical inferior and anterior wall. The mid antero-septum and apical lateral wall were hypokinetic. Interventional Cardiology and CTS recommended conservative management with medical optimization (Continue DAPT, heparin);, watchful waiting for the thrombus to resorb. Left main coronary artery thrombosis (LMCAT); identified during coronary angiography is a rare and challenging condition. It is a life threatening condition with an approximate incidence rate of 0.8 percent . It is thought to be secondary to plaque rupture with subsequent thrombus formation that is associated with persistent hypercoagulable state, cocaine induced plaque rupture or coronary vasospasm, post-partum state and embolization of intra-cardiac masses. The patient presentation can vary from sudden cardiac death to

  4. Incremental Value of Three-Dimensional Transesophageal Echocardiography over the Two-Dimensional Technique in the Assessment of a Thrombus in Transit through a Patent Foramen Ovale.

    Science.gov (United States)

    Thind, Munveer; Ahmed, Mustafa I; Gok, Gulay; Joson, Marisa; Elsayed, Mahmoud; Tuck, Benjamin C; Townsley, Matthew M; Klas, Berthold; McGiffin, David C; Nanda, Navin C

    2015-05-01

    We report a case of a right atrial thrombus traversing a patent foramen ovale into the left atrium, where three-dimensional transesophageal echocardiography provided considerable incremental value over two-dimensional transesophageal echocardiography in its assessment. As well as allowing us to better spatially characterize the thrombus, three-dimensional transesophageal echocardiography provided a more quantitative assessment through estimation of total thrombus burden. © 2015, Wiley Periodicals, Inc.

  5. Sensitivity of 3D gradient recalled echo susceptibility-weighted imaging technique compared to computed tomography angiography for detection of middle cerebral artery thrombus in acute stroke

    Directory of Open Access Journals (Sweden)

    Amit Agarwal

    2014-11-01

    Full Text Available We aimed at comparing the sensitivity of magnetic resonance (MR susceptibility-weighted imaging (SWI with computed tomography angiography (CTA in the detection of middle cerebral artery (MCA thrombus in acute stroke. Seventy-nine patients with acute MCA stroke was selected using our search engine software; only the ones showing restricted diffusion in the MCA territory on diffusion-weighted images were included. We finally selected 35 patients who had done both MRI (including SWI and CTA. Twenty random subjects with completely normal MRI (including SWI exam were selected as control. Two neuroradiologists (blinded to the presence or absence of stroke reviewed the SW images and then compared the findings with CT angiogram (in patients with stroke. The number of MCA segments showing thrombus in each patient was tabulated to estimate the thrombus burden. Thrombus was detected on SWI in one or more MCA segments in 30 out of 35 patients, on the first review. Of the 30, SWI showed thrombus in more than one MCA segments in 7 patients. CTA depicted branch occlusion in 31 cases. Thrombus was seen on both SWI and CTA in 28 patients. Thrombus was noted in two patients on SWI only, with no corresponding abnormality seen on CTA. Two patients with acute MCA showed no vascular occlusion or thrombus on either CTA or SWI. Only two case of false-positive thrombus was reported in normal control subjects. Susceptibility-weighted images had sensitivity and specificity of 86% and 90% respectively, with positive predictive value 94%. Sensitivity was 86% for SWI, compared with 89% for CTA, and this difference was statistically insignificant (P>0.05. Of all the positive cases on CTA (31 corresponding thrombus was seen on SWI in 90% of subjects (28 of 31. Susceptibility-weighted imaging has high sensitivity for detection of thrombus in acute MCA stroke. Moreover, SWI is a powerful technique for estimation of thrombus burden, which can be challenging on CTA.

  6. James Moores Ball: Ophthalmologist, medical historian, bibliophile.

    Science.gov (United States)

    Feibel, Robert M

    2016-08-01

    James Moores Ball (1862-1929) was an ophthalmologist in St. Louis, Missouri, who excelled as a medical historian and collector of rare and historic books about the history of anatomy. During his lifetime, he was best known as the author of a comprehensive, authoritative, and popular textbook titled Modern Ophthalmology First published in 1904, there were five further editions. Ball was very interested in the history of anatomy and wrote two books on this subject, the first being a biography of Andreas Vesalius, one of the earliest in English, and the second a history of the resurrection men or grave robbers who sold corpses to professors of anatomy and surgery for teaching purposes. His legacy today is the 470 volumes of his personal library, which are now in the Archives and Rare Books department of the Becker Medical Library of the Washington University School of Medicine. These texts are one of their major collections, concentrating on the history of anatomy, beginning with a first edition of Vesalius's De Humani Corporis Fabrica and holding many important and beautiful landmark volumes of anatomical atlases. © The Author(s) 2016.

  7. Crises in a dissipative bouncing ball model

    Energy Technology Data Exchange (ETDEWEB)

    Livorati, André L.P., E-mail: livorati@usp.br [Departamento de Física, UNESP, Universidade Estadual Paulista, Av. 24A, 1515, Bela Vista, 13506-900, Rio Claro, SP (Brazil); School of Mathematics, University of Bristol, Bristol, BS8 1TW (United Kingdom); Instituto de Física, IFUSP, Universidade de São Paulo, USP, Rua do Matão, Tr.R 187, Cidade Universitária, 05314-970, São Paulo, SP (Brazil); Caldas, Iberê L. [Instituto de Física, IFUSP, Universidade de São Paulo, USP, Rua do Matão, Tr.R 187, Cidade Universitária, 05314-970, São Paulo, SP (Brazil); Dettmann, Carl P. [School of Mathematics, University of Bristol, Bristol, BS8 1TW (United Kingdom); Leonel, Edson D. [Departamento de Física, UNESP, Universidade Estadual Paulista, Av. 24A, 1515, Bela Vista, 13506-900, Rio Claro, SP (Brazil)

    2015-11-06

    Highlights: • We studied a dissipative bouncing ball dynamics. • A two-dimensional nonlinear mapping describes the dynamics. • Crises between attractors and its manifolds were characterized. • A new physical crisis between vibrating platform and an attractor was characterized. • The existence of a ‘robust’ chaotic attractor was set. - Abstract: The dynamics of a bouncing ball model under the influence of dissipation is investigated by using a two-dimensional nonlinear mapping. When high dissipation is considered, the dynamics evolves to different attractors. The evolution of the basins of the attracting fixed points is characterized, as we vary the control parameters. Crises between the attractors and their boundaries are observed. We found that the multiple attractors are intertwined, and when the boundary crisis between their stable and unstable manifolds occurs, it creates a successive mechanism of destruction for all attractors originated by the sinks. Also, a physical impact crisis is described, an important mechanism in the reduction of the number of attractors.

  8. Effect of Adjunctive Thrombus Aspiration on In-Hospital and 3-Year Outcomes in Patients With ST-Segment Elevation Myocardial Infarction and Large Native Coronary Artery Thrombus Burden.

    Science.gov (United States)

    Keskin, Muhammed; Kaya, Adnan; Tatlısu, Mustafa Adem; Uzman, Osman; Börklü, Edibe Betül; Çinier, Göksel; Tekkeşin, Ahmet İlker; Türkkan, Ceyhan; Hayıroğlu, Mert İlker; Kozan, Ömer

    2017-11-15

    Although the long-term clinical benefit of adjunctive thrombus aspiration (TA) during primary percutaneous coronary intervention (PPCI) remains controversial, the impact of TA in patients with large thrombus has not been evaluated. The aim of the present study was to investigate the effect of adjunctive TA during PPCI on clinical outcomes in patients with ST-segment elevation myocardial infarction (STEMI) and a large thrombus. We assessed the effect of adjunctive TA on in-hospital and 3-year clinical outcomes in 627 patients with STEMI and a large thrombus in the native coronary artery. The cumulative 3-year incidence of all-cause death was not significantly different between the 2 groups (91.5% vs 89.0%, log-rank test p = 0.347). After adjusting for confounders, the risk of all-cause death in the TA group was not significantly lower than that in the non-TA group (hazard ratio 1.11, 95% confidence interval 0.60 to 3.54, p = 0.674). The adjusted risks of target lesion revascularization, nonfatal acute myocardial infarction, and stent thrombosis were also not significantly different between the 2 groups. In conclusion, adjunctive TA during PPCI was not associated with better in-hospital and 3-year all-cause deaths in patients with STEMI and a large coronary artery thrombus. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Comparison of the Effectiveness of Three Methods of Recanalization in a Model of the Middle Cerebral Artery: Thrombus Aspiration via a 4F Catheter, Thrombus Aspiration via the GP Thromboaspiration Device, and Mechanical Thrombectomy Using the Solitaire Thrombectomy Device

    Directory of Open Access Journals (Sweden)

    Christopher Tennuci

    2011-01-01

    Full Text Available Introduction. This paper compares different approaches to recanalization in a model of the middle cerebral artery (MCA. Methods. An occlusive thrombus (lamb's blood was introduced into the MCA of a model of the cerebral circulation perfused with Hartmann's solution (80 pulsations/min, mean pressure 90 mm Hg. Three methods of clot retrieval were tested: thrombus aspiration via a 4F catheter (n=26, thrombus aspiration via the GP thrombus aspiration device (GPTAD (n=30, and mechanical thrombectomy via the Solitaire Device (n=30. Results. Recanalization rate was similar for all 3 approaches (62%, 77%, and 85%. Time to recanalization was faster with aspiration devices (41 SD 42 s for 4F and 61 SD 21 s for GPTAD than with the Solitaire (197 SD 64 s P<.05 Kruksal-Wallis. Clot fragmentation was the same in the Solitaire (23% and the GPTAD (23%, but higher with the 4F (53%, P<.05. Conclusion. In this model, thrombus aspiration was faster than mechanical thrombectomy, and similarly effective at recanalization. These results should be confirmed in vivo.

  10. Modeling and Analyzing the Slipping of the Ball Screw

    Directory of Open Access Journals (Sweden)

    Nannan Xu

    Full Text Available AbstractThis paper aims to set up the ball systematic slipping model and analyze the slipping characteristics caused by different factors for a ball screw operating at high speeds. To investigate the ball screw slipping mechanism, transformed coordinate system should be established firstly. Then it is used to set up mathematical modeling for the ball slipping caused by the three main reasons and the speed of slipping can be calculated. Later, the influence of the contact angle, helix angle and screw diameter for ball screw slipping will be analyzed according to the ball slipping model and slipping speeds equa