WorldWideScience

Sample records for left renal perfusion

  1. Renal perfusion scintiscan

    Science.gov (United States)

    ... Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Rottenberg G, Andi AC. Renal ...

  2. Renal perfusion in chronic liver diseases: Evaluation by radiotechnetium renography

    International Nuclear Information System (INIS)

    Fanfani, G.; Fratello, A.; Mele, M.; Conte, E.; D'Addabbo, A.; Greco, L.

    1985-01-01

    Twenty-four patients with chronic liver diseases and seven normal controls were studied using renal and hepatic radiotechnetium angiography. The time-activity histograms generated were employed to calculate both the renal perfusion index (RPI) and the hepatic perfusion index (HPI). Renal perfusion proved to be reduced not only in cirrhotic patients but also in patients with aggressive chronic hepatitis, as well as in those with persistent chronic hepatitis. The HPI, which is to be considered as being strictly dependent on portal flow, only fell significantly in the group of cirrhotic patients. In all patient groups, the correlation coefficient between the HPI and RPI (mean of the two kidneys) was low (r=0.275) and not significant (P>0.05). After Warren's splenorenal derivation, renal perfusion did not improve but worsened, particularly in the left kidney where derivation anastomosis probably caused a venous overload. (orig.)

  3. In vivo MR perfusion imaging of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.; Lorenz, C.H.; Bain, R.; Holburn, G.; Price, R.R.

    1989-01-01

    Various techniques have been developed for noninvasive evaluation of renal blood flow. More important in the assessment of potential renal ischemia may be actual perfusion of the nephron mass. MR pulse sequences have been devised that allow perfusion imaging (PI) in a dog model of renal artery stenosis. Unilateral renal artery stenosis was created in mongrel dogs and quantitation of renal blood flow was obtained with radioactive microspheres. Perfusion imaging was performed on a 1.5-T system to obtain the apparent diffusion coefficient. During initial studies, it was found that the usual gradient factor used in brain PI was too high for renal studies; a factor of < 50 was found to be optimal. Additionally, respiratory gating with acquisition at end expiration was necessary to prevent renal motion. Recent studies have shown that PI reflects the asymmetry of flow in this model

  4. Automatic extraction of left ventricle in SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Liu Li; Zhao Shujun; Yao Zhiming; Wang Daoyu

    1999-01-01

    An automatic method of extracting left ventricle from SPECT myocardial perfusion data was introduced. This method was based on the least square analysis of the positions of all short-axis slices pixels from the half sphere-cylinder myocardial model, and used a iterative reconstruction technique to automatically cut off the non-left ventricular tissue from the perfusion images. Thereby, this technique provided the bases for further quantitative analysis

  5. Simultaneous determination of left ventricular perfusion and function

    International Nuclear Information System (INIS)

    Gremillet, E.; Champailler, A.; Esquerre, J.P.; Ouhayoun, E.; Coca, F.; Furber, A.; Le Jeune, J.J.

    1997-01-01

    Myocardial perfusion scintigraphy is a very useful tool for the diagnosis and prognosis of coronary artery disease. The evaluation of left ventricular function during stress testing in also very useful to determine the prognosis of coronary artery disease. This chapter highlights three different imaging methods to assess left ventricular function and myocardial perfusion/ The first one consists of sequential dual isotope myocardial SPECT with ECG-gating. The second concerns magnetic resonance imaging and the third explores first pass exercise ventriculography and myocardial perfusion scintigraphy simultaneously evaluated by means of 99m Tc-sestamibi. (authors)

  6. Myocardial perfusion in type 2 diabetes with left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Hesse, Birger; Meyer, Christian; Nielsen, Flemming S

    2004-01-01

    The purpose of this study was to assess whether acute angiotensin-converting enzyme (ACE) inhibition would improve myocardial perfusion and perfusion reserve in a subpopulation of normotensive patients with diabetes and left ventricular hypertrophy (LVH), both independent risk factors of coronary...... disease. Using positron emission tomography (PET), we investigated the response of regional myocardial perfusion to acute ACE inhibition with i.v. infusion of perindoprilat (vs saline infusion as control, minimum interval 3 days) in 12 diabetic patients with LVH. Myocardial perfusion was quantified...... with controls, maximal perfusion was reduced in patients (1.8+/-0.6 vs 2.5+/-1.0 ml min(-1) g(-1); P2.7+/-1.0 vs 3.6+/-1.3; P=0.059). During perindoprilat infusion, myocardial perfusion reserve in patients increased to 3.9+/-0.9 ( P

  7. The diagnosis of renal perfusion abnormalities by sequential CT

    International Nuclear Information System (INIS)

    Treugut, H.; Andersson, I.; Hildell, J.; Nyman, U.; Weibull, H.

    1981-01-01

    Abnormalities of renal perfusion can be recognised more readily by sequential CT than by plain CT scan or after static enhancement with contrast medium. Haemodynamically significant stenoses of the renal arteries and total, or partial, infarcts can be diagnosed in this way. Intrarenal and capsular collaterals can be recognised by slow contrast accumulation in the infarcted area, or by the development of contrast in the sub-capsular portion of the cortex. Renal cortical necrosis is very well demonstrated by the absence of cortical perfusion; this is seen, for instance, in the DIC syndrome or during rejection after renal transplant. (orig.) [de

  8. Diagnosis of renal perfusion abnormalities by sequential CT

    Energy Technology Data Exchange (ETDEWEB)

    Treugut, H; Andersson, I; Hildell, J; Nyman, U; Weibull, H

    1981-10-01

    Abnormalities of renal perfusion can be recognised more readily by sequential CT than by plain CT scan or after static enhancement with contrast medium. Haemodynamically significant stenoses of the renal arteries and total, or partial, infarcts can be diagnosed in this way. Intrarenal and capsular collaterals can be recognised by slow contrast accumulation in the infarcted area, or by the development of contrast in the sub-capsular portion of the cortex. Renal cortical necrosis is very well demonstrated by the absence of cortical perfusion; this is seen, for instance, in the DIC syndrome or during rejection after renal transplant.

  9. Retrospective respiratory triggering renal perfusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, Ulrike I.; Michaely, Henrik J.; Schoenberg, Stefan O. (Dept. of Clinical Radiology and Nuclear Medicine, Univ. Hospital Mannheim, Univ. of Heidelberg, Mannheim (Germany)), e-mail: ulrike.attenberger@medma.uni-heidelberg.de; Sourbron, Steven P. (Div. of Medical Physics, Univ. of Leeds, Leeds (United Kingdom)); Reiser, Maximilian F. (Dept. of Clinical Radiology, Univ. Hospitals Munich, Grosshadern, Ludwig-Maximilians-Univ., Munich (Germany))

    2010-12-15

    Background: Artifacts of respiratory motion are one of the well-known limitations of dynamic contrast-enhanced MRI (DCE-MRI) of the kidney. Purpose: To propose and evaluate a retrospective triggering approach to minimize the effect of respiratory motion in DCE-MRI of the kidney. Material and Methods: Nine consecutive patients underwent renal perfusion measurements. Data were acquired with a 2D saturation-recovery TurboFLASH sequence. In order to test the dependence of the results on size and location of the manually drawn triggering regions of interest (ROIs), three widely differing triggering regions were defined by one observer. Mean value, standard deviation, and variability of the renal function parameters plasma flow (FP), plasma volume (VP), plasma transit time (TP), tubular flow (FT), tubular volume (VT), and tubular transit time (TT) were calculated on a per-patient basis. Results: The results show that triggered data have adequate temporal resolution to measure blood flow. The overall average values of the function parameters were: 152.77 (FP), 15.18 (VP), 6,73 (TP), 18.50 (FT), 35.36 (VT), and 117.67 (TT). The variability (calculated in % SD from the mean value) for three different respiratory triggering regions defined on a per-patient basis was between 0.81% and 9.87% for FP, 1.45% and 8.19% for VP, 0% and 9.63% for TP, 2.15% and 12.23% for TF, 0.8% and 17.28% for VT, and 1.97% and 12.87% for TT. Conclusion: Triggering reduces the oscillations in the signal curves and produces sharper parametric maps. In contrast to numerically challenging approaches like registration and segmentation it can be applied in clinical routine, but a (semi)-automatic approach to select the triggering ROI is desirable to reduce user dependence.

  10. Renal perfusion image using harmonic ultrasound with microbble contrast agent: preliminary study

    International Nuclear Information System (INIS)

    Kim, Jung Hoon; Choi, Jae Ho; Han, Dong Chul; Lee, Hi Bahl; Choi, Deuk Lin; Eun, Hyo Won; Lee, Hun Jae

    2003-01-01

    To compare, in terms of their feasibility and normal range, 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic ultrasound (US) with a microbubble contrast agent for the evaluation of renal perfusion after renal transplantation. During a six-month period, thirty patients who had received a renal transplant underwent both 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic US with a microbubble contrast agent. Sonographic renal perfusion images were obtained before and after a bolus injection of the microbubble contrast agent Levovist TM (SH U 5084; Schering AG, Berlin, Germany) every 3 seconds for 3 minutes. Sonographic renal perfusion images were converted into a renal perfusion curve by a computer program and T peak of the curve thus obtained was compared with that of the 99m Tc-DTPA curve. Average T peak of the 99m Tc-DTPA renal perfusion curve was 16.2 seconds in the normal group and 39.6 seconds in the delayed perfusion group, while average T peak of the sonographic renal perfusion curve was 23.7 seconds and 46.2 seconds, respectively. T peak of the sonographic renal perfusion curve showed a good correlation with that of the 99m Tc-DTPA curve (correlation coefficient=0.8209; p=0.0001). The cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds (sensitivity=90%, specificity=95%). In patients who have received a renal transplant, the findings of renal perfusion imaging using harmonic US with a microbubble contrast agent show close correlation with those of 99m Tc-DTPA renal perfusion imaging. The optimal cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds

  11. Evaluation of allograft perfusion by radionuclide first-pass study in renal failure following renal transplantation

    International Nuclear Information System (INIS)

    Baillet, G.; Ballarin, J.; Urdaneta, N.; Campos, H.; Vernejoul, P. de; Fermanian, J.; Kellershohn, C.; Kreis, H.

    1986-01-01

    To assess the diagnostic value of indices measured on a first-pass curve, we performed 72 radionuclide renal first-pass studies (RFP) in 21 patients during the early weeks following renal allograft transplantation. The diagnosis was based on standard clinical and biochemical data and on fine needle aspiration biopsy (FNAB) of the transplant. Aortic and renal first-pass curves were filtered using a true low-pass filter and five different indices of renal perfusion were computed, using formulae from the literature. Statistical analysis performed on the aortic and renal indices indicated excellent reproducibility of the isotopic study. Although renal indices presented a rather large scatter, they all discriminated well between normal and rejection. Three indices have a particularly good diagnostic value. In the discrimination between rejection and Acute Tubular Necrosis (ATN), only one index gave satisfying results. The indices, however, indicate that there are probably ATN with an alternation of renal perfusion and rejection episodes where perfusion is almost intact. We conclude that radionuclide first-pass study allows accurate and reproducible quantitation of renal allograft perfusion. The measured parameters are helpful to follow up the course of a post-transplantation renal failure episode and to gain more insight into renal ischemia following transplantation. (orig.)

  12. Assessment of Cu-ETS as a PET radiopharmaceutical for evaluation of regional renal perfusion

    International Nuclear Information System (INIS)

    Green, Mark A.; Mathias, Carla J.; Willis, Lynn R.; Handa, Rajash K.; Lacy, Jeffrey L.; Miller, Michael A.; Hutchins, Gary D.

    2007-01-01

    The copper(II) complex of ethylglyoxal bis(thiosemicarbazone) (Cu-ETS) was evaluated as a positron emission tomography (PET) radiopharmaceutical for assessment of regional renal perfusion. Methods: The concordance of renal flow estimates obtained with 11- and 15-μm microspheres was confirmed in four immature farm pigs using co-injected 46 Sc- and 57 Co-microspheres administered into the left ventricle. With the use of both immature farm pigs (n=3) and mature Goettingen minipigs (n=6), regional renal radiocopper uptake following intravenous [ 64 Cu]Cu-ETS administration was compared to microsphere measurements of renal perfusion. The distribution and kinetics of [ 64 Cu]Cu-ETS were further studied by PET imaging of the kidneys. The rate of [ 64 Cu]Cu-ETS decomposition by blood was evaluated in vitro, employing octanol extraction to recover intact [ 64 Cu]Cu-ETS. Results: The co-injected 11- and 15-μm microspheres provided similar estimates of renal flow. A linear relationship was observed between the renal uptake of intravenous [ 64 Cu]Cu-ETS and regional renal perfusion measured using microspheres. [ 64 Cu]Cu-ETS provided high-quality PET kidney images demonstrating the expected count gradient from high-flow outer cortex to low-flow medulla. When incubated with pig blood in vitro at 37 o C, the [ 64 Cu]Cu-ETS radiopharmaceutical was observed to decompose with a half-time of 2.8 min. Conclusion: Cu-ETS appears suitable for use as a PET radiopharmaceutical for evaluation of regional renal perfusion, affording renal uptake of radiocopper that varies linearly with microsphere perfusion measurements. Quantification of renal perfusion (in ml min -1 g -1 ) with [ 60,61,62,64 Cu]Cu-ETS will require correcting the arterial input function for the fraction of blood radiocopper remaining present as the intact Cu-ETS radiopharmaceutical, since the Cu-ETS chelate has limited chemical stability in blood. Rapid octanol extraction of blood samples appears suitable as an approach

  13. Assessment of Cu-ETS as a PET radiopharmaceutical for evaluation of regional renal perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Green, Mark A. [Department of Industrial and Physical Pharmacy, Purdue University, West Lafayette, IN 47907 (United States)]. E-mail: magreen@purdue.edu; Mathias, Carla J. [Department of Industrial and Physical Pharmacy, Purdue University, West Lafayette, IN 47907 (United States); Willis, Lynn R. [Department of Pharmacology and Toxicology, Indiana University School of Medicine, Indianapolis, IN 46202 (United States); Handa, Rajash K. [Department of Pharmacology and Toxicology, Indiana University School of Medicine, Indianapolis, IN 46202 (United States); Lacy, Jeffrey L. [Proportional Technologies, Inc., Houston, TX 77054 (United States); Miller, Michael A. [Department of Radiology and the Indiana Center of Excellence in Biomedical Imaging, Indiana University School of Medicine, Indianapolis, IN 46202 (United States); Hutchins, Gary D. [Department of Radiology and the Indiana Center of Excellence in Biomedical Imaging, Indiana University School of Medicine, Indianapolis, IN 46202 (United States)

    2007-04-15

    The copper(II) complex of ethylglyoxal bis(thiosemicarbazone) (Cu-ETS) was evaluated as a positron emission tomography (PET) radiopharmaceutical for assessment of regional renal perfusion. Methods: The concordance of renal flow estimates obtained with 11- and 15-{mu}m microspheres was confirmed in four immature farm pigs using co-injected {sup 46}Sc- and {sup 57}Co-microspheres administered into the left ventricle. With the use of both immature farm pigs (n=3) and mature Goettingen minipigs (n=6), regional renal radiocopper uptake following intravenous [{sup 64}Cu]Cu-ETS administration was compared to microsphere measurements of renal perfusion. The distribution and kinetics of [{sup 64}Cu]Cu-ETS were further studied by PET imaging of the kidneys. The rate of [{sup 64}Cu]Cu-ETS decomposition by blood was evaluated in vitro, employing octanol extraction to recover intact [{sup 64}Cu]Cu-ETS. Results: The co-injected 11- and 15-{mu}m microspheres provided similar estimates of renal flow. A linear relationship was observed between the renal uptake of intravenous [{sup 64}Cu]Cu-ETS and regional renal perfusion measured using microspheres. [{sup 64}Cu]Cu-ETS provided high-quality PET kidney images demonstrating the expected count gradient from high-flow outer cortex to low-flow medulla. When incubated with pig blood in vitro at 37{sup o}C, the [{sup 64}Cu]Cu-ETS radiopharmaceutical was observed to decompose with a half-time of 2.8 min. Conclusion: Cu-ETS appears suitable for use as a PET radiopharmaceutical for evaluation of regional renal perfusion, affording renal uptake of radiocopper that varies linearly with microsphere perfusion measurements. Quantification of renal perfusion (in ml min{sup -1} g{sup -1}) with [{sup 60,61,62,64}Cu]Cu-ETS will require correcting the arterial input function for the fraction of blood radiocopper remaining present as the intact Cu-ETS radiopharmaceutical, since the Cu-ETS chelate has limited chemical stability in blood. Rapid octanol

  14. Role of pressure in angiotensin II-induced renal injury: chronic servo-control of renal perfusion pressure in rats.

    Science.gov (United States)

    Mori, Takefumi; Cowley, Allen W

    2004-04-01

    Renal perfusion pressure was servo-controlled chronically in rats to quantify the relative contribution of elevated arterial pressure versus angiotensin II (Ang II) on the induction of renal injury in Ang II-induced hypertension. Sprague-Dawley rats fed a 4% salt diet were administered Ang II for 14 days (25 ng/kg per minute IV; saline only for sham rats), and the renal perfusion pressure to the left kidney was continuously servo-controlled to maintain a normal pressure in that kidney throughout the period of hypertension. An aortic occluder was implanted around the aorta between the two renal arteries and carotid and femoral arterial pressure were measured continuously throughout the experiment to determine uncontrolled and controlled renal perfusion pressure, respectively. Renal perfusion pressure of uncontrolled, controlled, and sham kidneys over the period of Ang II or saline infusion averaged 152.6+/-7.0, 117.4+/-3.5, and 110.7+/-2.2 mm Hg, respectively. The high-pressure uncontrolled kidneys exhibited tubular necrosis and interstitial fibrosis, especially prominent in the outer medullary region. Regional glomerular sclerosis and interlobular artery injury were also pronounced. Controlled kidneys were significantly protected from interlobular artery injury, juxtamedullary glomeruli injury, tubular necrosis, and interstitial fibrosis as determined by comparing the level of injury. Glomerular injury was not prevented in the outer cortex. Transforming growth factor (TGF)-beta and active NF-kappaB proteins determined by immunohistochemistry were colocalized in the uncontrolled kidney in regions of interstitial fibrosis. We conclude that the preferential juxtamedullary injury found in Ang II hypertension is largely induced by pressure and is probably mediated through the TGF-beta and NF-kappaB pathway.

  15. Machine perfusion for improving outcomes following renal transplant: current perspectives

    Directory of Open Access Journals (Sweden)

    Cannon RM

    2016-03-01

    Full Text Available Robert M Cannon,1 Glen A Franklin1,2 1The Hiram C Polk Jr MD Department of Surgery, University of Louisville, 2Kentucky Organ Donor Affiliates, Louisville, KY, USAAbstract: There is a disparity between the number of kidneys available for transplantation and the number of patients awaiting an organ while on dialysis. The current kidney waiting list in the US contains more than 100,000 patients. This need has led to the inclusion of older donors with worsening renal function, as well as greater utilization of kidneys from non-heartbeating (donation after cardiac death donors. Coinciding with this trend has been a growing interest in technology to improve the function of these more marginal organs, the most important of which currently is machine perfusion (MP of donated kidneys after procurement. While this technology has no standard guidelines currently for comprehensive use, there are many studies that demonstrate higher organ yield and function after a period of MP. Particularly with the older donor and during donation after cardiac death cases, MP may offer some significant benefits. This manuscript reviews all of the current literature regarding MP and its role in renal transplantation. We will discuss both the experience in Europe and the US using machine perfusion for donated kidneys.Keywords: machine perfusion, renal transplantation, kidney pumping, renal failure, organ donation

  16. Can preoperative myocardial perfusion scintigraphy predict changes in left ventricular perfusion and function after coronary artery bypass graft surgery?

    DEFF Research Database (Denmark)

    Eckardt, Rozy; Kjeldsen, Bo Juel; Johansen, Allan

    2012-01-01

    OBJECTIVESWe wanted to evaluate whether preoperative myocardial perfusion scintigraphy (MPS) could predict changes in cardiac symptoms and postoperative myocardial perfusion and left ventricular function after coronary artery bypass grafting (CABG).METHODSNinety-two patients with stable angina...... in 26%. Left ventricular ejection fraction (LVEF), which was normal before operation in 45%, improved in 40% of all patients. The increase in LVEF was not related to the preoperative pattern of perfusion defects. Of 30 patients with normalized perfusion after CABG, 29 (97%) had reversible defects...... that reversible or partly reversible perfusion defects at a preoperative MPS have a high chance of normalized myocardial perfusion assessed by MPS 6 months after operation. Normal perfusion is obtained almost exclusively in territories with reversible ischaemia. Symptoms improved in nearly all patients and LVEF...

  17. LEFT RENAL TUMOR: A RARE CADAVERIC FINDINGS

    Directory of Open Access Journals (Sweden)

    Siva Prasad

    2015-08-01

    Full Text Available A benign tumour is a non - cancerous growth that does not spread (metastasize to other parts of the body and is not usually life - threatening. Many researchers believe that most of the following types of kidney tumours are benign. However, others feel that some of these tumours have the potential to develop into renal cell carcinoma. There are no diagnostic tests that can confirm if a benign tumour has the potential to become cancerous. Benign tumours are sometimes found along with renal cell carcinoma when a removed kidney is examined by a pathologist. For these reasons, benign kidney tumours are treated like malignant tumours. In this case we have observed a male cadaver with a large tumour in the left kidney during our routine dissections of undergraduates .

  18. Quantitative analysis of MR perfusion/diffusion images in a dog model of renal artery stenosis with microsphere correlation

    International Nuclear Information System (INIS)

    Lorens, C.H.; Powers, T.A.; Holburn, G.E.; Price, R.R.

    1990-01-01

    This paper compares MR perfusion/diffusion-derived parameters with microsphere determination of asymmetry of renal perfusion in a dog model of renal artery stenosis. A left renal artery stenosis was created by placement of a silk ligature. Nb-95-labeled microspheres were injected into the left ventricle, and a reference blood sample was drawn. The dog was imaged in a 1.5-T MR imager with both spin-echo and turbo-FLASH perfusion/diffusion-sensitive pulse sequences. The kidneys were excised, weighted, divided into sections, and counted. Two dogs have been studied to date. In dog 1, left renal blood flow (RBF) was 42 mL/min/100g and right RBF was 337 mL/min/100g. In dog 2 left RBF was 444 mL/min/100g and right RBF was 608 mL/min/100g. The apparent diffusion coefficients (ADC) reflected the asymmetry of flow in dog 1 for both spin-echo and turbo-FLASH sequences (RADC/LADC = 1.7) and showed essentially equal flow in dog 2(RADC/LADC = 0.7)

  19. Evaluation of renal transplant perfusion by functional imaging

    International Nuclear Information System (INIS)

    Nicoletti, R.

    1990-01-01

    Radionuclide angiography (RNA) is used as a noninvasive method for the evaluation of renal transplant perfusion. The computer processing method generally used, based on regions of interest, is unsatisfactory because it does not permit the regional differentiation of perfusion defects. Furthermore, the subjective delineation of the regions of interest introduces considerable inter-observer variation of results. We developed a processing method which is less operator-dependent and permits the evaluation of local defects; it is based on the concept of functional imaging. The method was evaluated in 62 patient examinations, which were subdivided into four groups: Normal transplant perfusion (23 examinations), acute tubular necrose (ATN) (16), cellular rejection (13), and vascular rejection (10). Quantitative results derived from profile curves were combined with visual estimation of the functional images and yielded a synoptic graph which allowed differentiation into three groups: Normal transplant perfusion (sensitivity 0.78, specificity 0.97), ATN or cellular rejection (sens. 0.83, spec. 0.82), and vascular rejection (sens. 0.90, spec. 0.92). (orig.)

  20. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    International Nuclear Information System (INIS)

    Bair, H.J.; Platsch, G.; Wolf, F.; Guenter, E.; Becker, D.; Rupprecht, H.; Neumayer, H.H.

    1997-01-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [de

  1. Specific perfusion pattern in stress 201Tl myocardial scintigraphy of left main coronary artery disease

    International Nuclear Information System (INIS)

    Wakasugi, Shigetoshi; Shibata, Nobuhiko; Kobayashi, Tohru; Fudemoto, Yoshiyuki; Hasegawa, Yoshihisa; Nakano, Shunichi

    1986-01-01

    The usefulness of stress 201 Tl myocardial scintigraphy for identifying left main coronary artery disease was evaluated with data from 23 patients with 50% or more narrowing of the left main coronary artery and 56 patients with 75% or more narrowing of the major coronary arteries but without left main coronary artery involvement (no left main coronary artery disease). Quantitative evaluation of stress perfusion scintigrams in all five patients with narrowing of the left main coronary artery of 90% or more showed a characteristic perfusion pattern (left main pattern) of extensive homogeneous defect over the whole anterolateral segment and simultaneous defects in all radii of the high anteroseptal and high posterolateral segments. On the other hand, such a perfusion pattern was noted in only 1 of 18 patients with less than 90% stenosis of the left main coronary artery and in only 1 of 56 patients with no left coronary artery disease. (orig.)

  2. Gated spect myocardial perfusion scintigraphy for identifying septal perfusion artifacts in left bundle branch block

    International Nuclear Information System (INIS)

    Afzal, M.S.; Imran, M.B.; Akhtar, M.S.; Muhammand, K.; Nadeem, A.; Aslam, N.; Khurshid, S.J.; Farooq, U.I.; Sohaib, M.

    2006-01-01

    To determine the role of gated Single Photon Emission Computed Tomography (SPECT) for accurate assessment of myocardial perfusion scintigraphy (MPS) of patients with left bundle branch block (LBBB). MPS data of patients with LBBB was analyzed. Resting gated SPECT MPS was performed after an injection of 740 MBq 99mTc-MIBI in 10 normal and 25 subjects with LBBB (with low probability of coronary artery disease). Visual and quantitative analyses were done on non-gated (NG), end diastolic (ED), end systolic (ES) images. Calculations included septal to lateral wall ratio (SLR), myocardial thickening (MT=% increase in counts during systole) at end systolic phase and myocardial thickening at peak level (% peak MT). Septal hypoperfusion was noted in 19 (76%) patients on NG images and in only 1 (4%) patient on gated SPECT ED images. On NG images of LBBB group, SLR was lower than in controls (0.68 +- 0.07 vs. 0.87 +- 0.05, p<0.001). SLR of LBBB patients approached to that of control group in gated SPECT ED data (0.86 +- 0.06 vs 0.88 +- 0.06, p=ns). Myocardial thickening at ES for septum was markedly lower in LBBB group than in controls (21.83% +- 10.86 vs. 66.32% +- 20.15, p<0.001). (author)

  3. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  4. Left versus right deceased donor renal allograft outcome.

    LENUS (Irish Health Repository)

    Phelan, Paul J

    2009-12-01

    It has been suggested that the left kidney is easier to transplant than the right kidney because of the longer length of the left renal vein, facilitating the formation of the venous anastomosis. There are conflicting reports of differing renal allograft outcomes based on the side of donor kidney transplanted (left or right).We sought to determine the effect of side of donor kidney on early and late allograft outcome in our renal transplant population. We performed a retrospective analysis of transplanted left-right deceased donor kidney pairs in Ireland between January 1, 1998 and December 31, 2008. We used a time to death-censored graft failure approach for long-term allograft survival and also examined serum creatinine at different time points post-transplantation. All outcomes were included from day of transplant onwards. A total of 646 transplants were performed from 323 donors. The incidence of delayed graft function was 16.1% in both groups and there was no significant difference in acute rejection episodes or serum creatinine from 1 month to 8 years post-transplantation.There were 47 death-censored allograft failures in the left-sided group compared to 57 in the right-sided group (P = 0.24). These observations show no difference in renal transplant outcome between the recipients of left- and right-sided deceased donor kidneys.

  5. Prognostic Value of Normal Perfusion but Impaired Left Ventricular Function in the Diabetic Heart on Quantitative Gated Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hwanjeong; Choi, Sehun; Han, Yeonhee [Research Institute of Chonbuk National Univ. Medical School and Hospitial, Jeonju (Korea, Republic of); Lee, Dong Soo; Lee, Hoyoung; Chung, Junekey [Seoul National Univ., Seoul (Korea, Republic of)

    2013-09-15

    This study aimed at identifying the predictive parameters on quantitative gated myocardial perfusion single-photon emission computed tomography (QG-SPECT) in diabetic patients with normal perfusion but impaired function. Methods Among the 533 consecutive diabetic patients, 379 patients with normal perfusion on rest Tl-201/dipyridamole-stress Tc-{sup 99m} sestamibi Gated SPECT were enrolled. Patients were grouped into those with normal post-stress left ventricular function (Group I) and those with impaired function (EF <50 or impaired regional wall motion, Group II). We investigated cardiac events and cause of death by chart review and telephone interview. Survival analysis and Cox proportional hazard model analysis were performed. Between the Group I and II, cardiac events as well as chest pain symptoms, smoking, diabetic complications were significantly different (P<0.05). On survival analysis, event free survival rate in Group II was significantly lower than in Group I (P=0.016). In univariate Cox proportional hazard analysis on overall cardiac event, Group (II over I), diabetic nephropathy, summed motion score (SMS), summed systolic thickening score (STS), numbers of abnormal segmental wall motion and systolic thickening predicted more cardiac events (P<0.05). Multivariate analysis showed that STS was the only independent predictor cardiac event. The functional parameter, especially summed systolic thickening score on QG-SPECT had prognostic values, despite normal perfusion, in predicting cardiac events in diabetic patients, and QG-SPECT provides clinically useful risk stratification in diabetic patients with normal perfusion.

  6. Time-resolved MR angiography of the renal artery: morphology and perfusion

    International Nuclear Information System (INIS)

    Krause, U.J.; Pabst, T.; Koestler, H.; Helbig, C.; Kenn, W.; Hahn, D.

    2002-01-01

    Purpose: To prove the hypothesis that renal artery stenosis and changes in renal perfusion can be detected with contrast-enhanced time-resolved MR angiography in a single examination. Material and Methods: In 71 patients, 137 renal arteries and 14 accessory renal arteries were studied. The examinations were performed on a 1.5 T system. A T 1 -weighted gradient echo sequence with a temporal resolution of 7 s was used. Single dose of contrast material (0.1 mmol/kg Gd-DTPA) was injected with a power injector with a flow rate of 2 ml/s. Criterion for the assessment of renal perfusion was the slope ratio of the signal intensity time curve in both kidneys. Results: Forty renal artery stenoses and one occlusion of a renal artery were detected. In 48 kidneys (35%) segmental arteries were evaluated. The accuracy of the slope ratio (limit value 0.75) concerning the detection of unilateral renal artery stenosis was 92.6% (sensitivity 75%, specificity 95.7%). Conclusion: Time-resolved MR angiography can detect changes in renal perfusion in patients with unilateral renal artery stenosis. (orig.) [de

  7. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress 99m Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest 123 I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and 123 I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by 123 I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in 123 I-BMIPP). Eighteen normotensive patients with apical defect by 123 I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by 123 I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by 123 I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and 123 I-BMIPP imaging are useful for the identification of these patients. (author)

  8. Bicornuate unicollis uterus with left renal agenesis | Adeyinka ...

    African Journals Online (AJOL)

    This is a case report of a 30 year old lady with 8 years history of 2 Infertility. Radiological findings by Hystero-salpingography (HSG) revealed a Bicornuate Unicolis uterus. This was further confirmed by Ultrasound, which also demonstrated a Left Renal agenesis inclusive. Radiological features, clinical presentation and ...

  9. Left ventricular hypertrophy in renal failure review | Arodiwe ...

    African Journals Online (AJOL)

    Renal failure is becoming increasingly common in our enironment. Advances in management like availability of dialysis and transplantation is prolonging the live of patients. As a consequence complication are increasingly being encountered. Cardiovascular complication is one of the commonest; and left ventricular ...

  10. Left sided circumaortic and retroaortic left renal veins, renal artery arising from iliac common artery in L-shaped kidney

    International Nuclear Information System (INIS)

    Al-Amin, M.

    2012-01-01

    Full text: Introduction: Renal ectopia is a congenital anomaly with variable clinical presentation. Kidneys are normally located in the retroperitoneal position, on either side of vertebral column, against the psoas muscles but when not at such position, it is called renal ectopia or ectopic kidney. Ectopic kidneys are thought to occur in approximately 1 in 1,000 births but only about 1 in 10 of these is ever diagnosed. In 90% of crossed ectopy, there is at least partial fusion of the kidneys. Left-to right ectopy is thought to be three times more common. Some of these are discovered incidentally, when a child or adult is having ultrasonography for a medical condition unrelated to renal ectopia. In a crossed fused renal ectopic kidney, complications such as nephrolithiasis, infection, and hydronephrosis approaches over 50%. Simple renal ectopia refers to kidney that is located on the proper side but abnormal in position. Crossed renal ectopia was first described by Pannorlus in 1964 and refer to kidney that has crossed from left to right or vice-versa, with moving of one kidney to the opposite side following ascent of the other kidney, so that both kidneys are located on the same side of the body, mostly fused called crossed fused ectopia. The fusion of the two kidneys is believed to result from (1) failure of the primitive nephrogenic cell masses to separate or (2) fusion of the two blastemas during their abdominal ascent. Discussion: A 57-year-old woman with a new found hematological disease. CT exam was performed with intravenous application of contrast media. Like an additional findings we visualized the presence of right to-left ectopy (L - shaped kidney) and the presence of left circumaortic renal vein emanating from a normally situated left kidney and retroaortic renal vein as having been located by the ectopic right kidney. Conclusion: By crossed renal ectopia is meant congenital displacement of one kidney to the opposite side. The conditional may present

  11. Abolished ventilation and perfusion of lung caused by blood clot in the left main bronchus

    DEFF Research Database (Denmark)

    Afzelius, P; Bergmann, A; Henriksen, J H

    2015-01-01

    /Q) scintigraphy with single-photon emission CT (SPECT)/CT. V/Q SPECT/CT demonstrated abolished ventilation due to obstruction of the left main bronchus and markedly reduced perfusion of the entire left lung, a condition that was completely reversed after removal of a blood clot. We present the first pictorially......It is generally assumed that the lungs possess arterial autoregulation associated with bronchial obstruction. A patient with pneumonia and congestive heart failure unexpectedly developed frequent haemoptysis. High-resolution CT and diagnostic CT were performed as well as ventilation/perfusion (V...

  12. Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results.

    Science.gov (United States)

    Lanzman, Rotem S; Wittsack, Hans-Jörg; Martirosian, Petros; Zgoura, Panagiota; Bilk, Philip; Kröpil, Patric; Schick, Fritz; Voiculescu, Adina; Blondin, Dirk

    2010-06-01

    To quantify renal allograft perfusion in recipients with stable allograft function and acute decrease in allograft function using nonenhanced flow-sensitive alternating inversion recovery (FAIR)-TrueFISP arterial spin labeling (ASL) MR imaging. Following approval of the local ethics committee, 20 renal allograft recipients were included in this study. ASL perfusion measurement and an anatomical T2-weighted single-shot fast spin-echo (HASTE) sequence were performed on a 1.5-T scanner (Magnetom Avanto, Siemens, Erlangen, Germany). T2-weighted MR urography was performed in patients with suspected ureteral obstruction. Patients were assigned to three groups: group a, 6 patients with stable allograft function over the previous 4 months; group b, 7 patients with good allograft function who underwent transplantation during the previous 3 weeks; group c, 7 allograft recipients with an acute deterioration of renal function. Mean cortical perfusion values were 304.8 +/- 34.4, 296.5 +/- 44.1, and 181.9 +/- 53.4 mg/100 ml/min for groups a, b and c, respectively. Reduction in cortical perfusion in group c was statistically significant. Our results indicate that ASL is a promising technique for nonenhanced quantification of cortical perfusion of renal allografts. Further studies are required to determine the clinical value of ASL for monitoring renal allograft recipients.

  13. Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results

    International Nuclear Information System (INIS)

    Lanzman, Rotem S.; Wittsack, Hans-Joerg; Bilk, Philip; Kroepil, Patric; Blondin, Dirk; Martirosian, Petros; Schick, Fritz; Zgoura, Panagiota; Voiculescu, Adina

    2010-01-01

    To quantify renal allograft perfusion in recipients with stable allograft function and acute decrease in allograft function using nonenhanced flow-sensitive alternating inversion recovery (FAIR)-TrueFISP arterial spin labeling (ASL) MR imaging. Following approval of the local ethics committee, 20 renal allograft recipients were included in this study. ASL perfusion measurement and an anatomical T2-weighted single-shot fast spin-echo (HASTE) sequence were performed on a 1.5-T scanner (Magnetom Avanto, Siemens, Erlangen, Germany). T2-weighted MR urography was performed in patients with suspected ureteral obstruction. Patients were assigned to three groups: group a, 6 patients with stable allograft function over the previous 4 months; group b, 7 patients with good allograft function who underwent transplantation during the previous 3 weeks; group c, 7 allograft recipients with an acute deterioration of renal function. Mean cortical perfusion values were 304.8 ± 34.4, 296.5 ± 44.1, and 181.9 ± 53.4 mg/100 ml/min for groups a, b and c, respectively. Reduction in cortical perfusion in group c was statistically significant. Our results indicate that ASL is a promising technique for nonenhanced quantification of cortical perfusion of renal allografts. Further studies are required to determine the clinical value of ASL for monitoring renal allograft recipients. (orig.)

  14. Collateral veins in left renal vein stenosis demonstrated via CT

    Energy Technology Data Exchange (ETDEWEB)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-02-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development.

  15. Collateral veins in left renal vein stenosis demonstrated via CT

    International Nuclear Information System (INIS)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-01-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development. (orig.)

  16. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Bair, H.J.; Platsch, G.; Wolf, F. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Nuclear Medicine; Guenter, E.; Becker, D. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 1; Rupprecht, H.; Neumayer, H.H. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 4

    1997-08-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [Deutsch] Ziel der Studie war es, das

  17. Correlation between nuclear perfusion parameters and duplex US indices in the diagnosis of renal allograft rejection

    International Nuclear Information System (INIS)

    Kim, E.E.; Maklad, N.F.; Pjura, G.A.; Lowry, P.A.

    1986-01-01

    Fifty nuclear perfusion and duplex US studies in 30 patients who had received renal allografts were prospectively analyzed to evaluate their respective measures of blood flow as indicators of rejection. The nuclear study (Tc-99m DTPA) generated three parameters, and a real-time, pulsed Doppler sector scanner generated resistance and pulsatility indices. In nine cases with a greater than 70% resistance index and 1.4 pulsatility index on US, the US findings correlated well with changes in nuclear perfusion parameters, indication rejection. The authors conclude that the combination of decreasing nuclear perfusion parameters and positive US indices may obviate the need for biopsy in the diagnosis of allograft rejection

  18. Renal hemodynamic changes with aging: a preliminary study using CT perfusion in the healthy elderly.

    Science.gov (United States)

    Zhao, Hong; Gong, Jingshan; Wang, Yan; Zhang, Zuoquan; Qin, Peixin

    2010-01-01

    To investigate renal blood flow perfusion parameter changes associated with aging using multislice spiral computed tomography (CT). This prospective study was approved by the institute's ethics committee for clinical study and written informed consent was obtained from all subjects. Forty-two consecutive patients who underwent abdominal CT without obvious renal abnormality at plain scanning were enrolled in this study. The renal perfusion scan was carried out using 16-slice spiral CT. The Pearson correlation coefficient was used to examine the correlation between perfusion parameter changes with aging. In both the cortex and medulla, blood flow (BF) and blood volume (BV) were negatively correlated with age, while time-to-peak (TTP) value and mean transit time (MTT) showed a positive correlation with age. Changes in BF, TTP, and MTT were found to have a statistically significant correlation with age in both the cortex and medulla, while the correlation between BV and age showed no statistical significance. It is feasible to assess renal hemodynamics changes with aging in the elderly using the current clinically available CT perfusion imaging technology in vivo. It may be helpful in the management of aged patients to familiarize with the renal hemodynamics changes in clinical work-up. Copyright 2010 Elsevier Inc. All rights reserved.

  19. MR measures of renal perfusion, oxygen bioavailability and total renal blood flow in a porcine model: noninvasive regional assessment of renal function.

    Science.gov (United States)

    Wentland, Andrew L; Artz, Nathan S; Fain, Sean B; Grist, Thomas M; Djamali, Arjang; Sadowski, Elizabeth A

    2012-01-01

    Magnetic resonance imaging (MRI) may be a useful adjunct to current methods of evaluating renal function. MRI is a noninvasive imaging modality that has the ability to evaluate the kidneys regionally, which is lacking in current clinical methods. Other investigators have evaluated renal function with MRI-based measurements, such as with techniques to measure cortical and medullary perfusion, oxygen bioavailability and total renal blood flow (TRBF). However, use of all three techniques simultaneously, and therefore the relationships between these MRI-derived functional parameters, have not been reported previously. To evaluate the ability of these MRI techniques to track changes in renal function, we scanned 11 swine during a state of hyperperfusion with acetylcholine and a saline bolus and subsequently scanned during a state of hypoperfusion with the prolonged use of isoflurane anesthesia. For each time point, measurements of perfusion, oxygen bioavailability and TRBF were acquired. Measurements of perfusion and oxygen bioavailability were compared with measurements of TRBF for all swine across all time points. Cortical perfusion, cortical oxygen bioavailability, medullary oxygen bioavailability and TRBF significantly increased with the acetylcholine challenge. Cortical perfusion, medullary perfusion, cortical oxygen bioavailability and TRBF significantly decreased during isoflurane anesthesia. Cortical perfusion (Spearman's correlation coefficient = 0.68; P renal function. Maintenance of the medullary oxygen bioavailability in low blood flow states may reflect the autoregulation particular to this region of the kidney. The ability to non-invasively measure all three parameters of kidney function in a single MRI examination and to evaluate the relationships between these functional parameters is potentially useful for evaluating the state of the human kidneys in situ in future studies.

  20. Renal MR angiography and perfusion in the pig using hyperpolarized water.

    Science.gov (United States)

    Wigh Lipsø, Kasper; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling; Laustsen, Christoffer; Ardenkjaer-Larsen, Jan Henrik

    2017-09-01

    To study hyperpolarized water as an angiography and perfusion tracer in a large animal model. Protons dissolved in deuterium oxide (D 2 O) were hyperpolarized in a SPINlab dissolution dynamic nuclear polarization (dDNP) polarizer and subsequently investigated in vivo in a pig model at 3 Tesla (T). Approximately 15 mL of hyperpolarized water was injected in the renal artery by hand over 4-5 s. A liquid state polarization of 5.3 ± 0.9% of 3.8 M protons in 15 mL of deuterium oxide was achieved with a T 1 of 24 ± 1 s. This allowed injection through an arterial catheter into the renal artery and subsequently high-contrast imaging of the entire kidney parenchyma over several seconds. The dynamic images allow quantification of tissue perfusion, with a mean cortical perfusion of 504 ± 123 mL/100 mL/min. Hyperpolarized water MR imaging was successfully demonstrated as a renal angiography and perfusion method. Quantitative perfusion maps of the kidney were obtained in agreement with literature and control experiments with gadolinium contrast. Magn Reson Med 78:1131-1135, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  1. Association between left ventricular perfusion defects and myocardial deformation indexes in heart transplantation recipients.

    Science.gov (United States)

    D'Andrea, Antonello; De Rimini, Maria Luisa; America, Raffaella; Cirillo, Chiara; Riegler, Lucia; Limongelli, Giuseppe; D'Alto, Michele; Salerno, Gemma; Maiello, Ciro; Muto, Pietro; Russo, Maria Giovanna; Calabrò, Raffaele; Bossone, Eduardo; Pacileo, Giuseppe

    2017-10-01

    The aim of the study was to analyze possible correlations between strain echocardiography (STE) and PET myocardial perfusion in a population of heart transplantation (HTx) recipients showing preserved left ventricular (LV) ejection fraction. By STE, LV global longitudinal strain (LV GLS) was lower in HTx. PET showed no transient or chronic ischemia in 83 of 115 HTx (73%). Fixed perfusion defects were observed in 17% of HTx and reversible ischemia in 10%. Significant coronary stenosis was observed only in 10 cases. GLS was independently associated with age at HTx and fixed perfusion defects (HR 0.41; P<.001). Such relationships underline STE ability to early identify HTx pts with subclinical myocardial dysfunction during long-term follow-up. © 2017, Wiley Periodicals, Inc.

  2. Overexpressed connective tissue growth factor in cardiomyocytes attenuates left ventricular remodeling induced by angiotensin II perfusion.

    Science.gov (United States)

    Zhang, Ying; Yan, Hua; Guang, Gong-Chang; Deng, Zheng-Rong

    2017-01-01

    To evaluate the improving effects of specifically overexpressed connective tissue growth factor (CTGF) in cardiomyocytes on mice with hypertension induced by angiotensin II (AngII) perfusion, 24 transgenic mice with cardiac-restricted overexpression of CTGF (Tg-CTGF) were divided into two equal groups that were perfused with acetic acid and AngII, respectively, for 7 days. Another 24 cage-control wild-type C57BL/6 mice (NLC) were divided and treated identically. Blood pressure was detected by caudal artery cannulation. Cardiac structural and functional changes were observed by echocardiography. Cardiac fibrosis was detected by Masson staining. After AngII perfusion, blood pressures of NLC and Tg-CTGF mice, especially those of the formers, significantly increased. Compared with NLC + AngII group, Tg-CTGF + AngII group had significantly lower left ventricular posterior wall thickness at end-diastole and left ventricular posterior wall thickness at end-systole as well as significantly higher left ventricular end-systolic diameter and left ventricular end-diastolic diameter (P tissues (P < 0.05). Tg-CTGF can protect AngII-induced cardiac remodeling of mice with hypertension by mitigating inflammatory response. CTGF may be a therapy target for hypertension-induced myocardial fibrosis, but the detailed mechanism still needs in-depth studies.

  3. Gadolinium-enhanced turbo FLASH MR imaging of renal perfusion and excretion

    International Nuclear Information System (INIS)

    Watanabe, A.; Teresi, L.M.; Herbst, M.; O'Sullivan, R.M.; Lee, R.; Smith, C.; Renner, J.; Rappaport, A.; Bradley, W.G. Jr.

    1990-01-01

    This paper describes a novel approach to MR imaging of renal perfusion and excretion using gadolinium-enhanced, T1-weighted TURBP, fast low-angle shot (FLASH) imaging. Five normal volunteers and four patients were studied on a 1.5-T imaging system. Time-intensity curves of the appearance of gadolinium in each kidney and the bladder were then generated. In normal volunteers, marked first-pass enhancement of renal cortex followed by renal pyramids and collecting systems could be demonstrated on the first-pass gadolinium images. Delayed images showed hyperintense gadolinium within the bladder

  4. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block

    OpenAIRE

    Cabeda, Est?van Vieira; Falc?o, Andr?a Maria Gomes; Soares Jr., Jos?; Rochitte, Carlos Eduardo; Nomura, C?sar Higa; ?vila, Luiz Francisco Rodrigues; Parga, Jos? Rodrigues

    2015-01-01

    Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and comp...

  5. Improved left ventricular function and perfusion at rest after successful transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Klepzig, H.; Kaltenbach, M.; Standke, R.; Maul, F.D.; Hoer, G.

    1991-01-01

    The purpose of this study was to evaluate left ventricular function and perfusion at rest before and after percutaneous transluminal coronary angioplasty. In consecutive 69 patients in whom coronary stenoses were dilated, the radionuclide left ventricular ejection fraction at rest increased significantly. In 26 of these patients, the ejection fraction increased by at least 4%. In these patients, exercise-induced ischemic ST depression had been more pronounced than in the others. 36 other patients underwent 201 Tl myocardial scintigraphy before and after angioplasty. Twelve patients in whom pre-PTCA images had revealed regions with irreversible 201 Tl uptake defects, showed normal 201 Tl distribution patterns on post-PTCA scintigrams. Post-exercise 201 Tl uptake (representing myocardial perfusion and metabolic activity) during pre-PTCA exercise stress tests was significantly lower in these cases. It is concluded that PTCA can improve left ventricular function and perfusion at rest. This improvement is most obvious in patients with pronounced exercise-induced myocardial ischemia as diagnosed by typical ST segment depression and reduced thallium uptake. (orig.) [de

  6. Scleroderma Renal Crisis: A Reversible Cause of Left Ventricular Dysfunction.

    Science.gov (United States)

    Martínez-Milla, Juan; Gaebelt, Hans Paul; Sánchez-Pernaute, Olga; Kallmeyer, Andrea; Romero, José; Farré, Jerónimo

    2018-05-02

    We report a case of acute left ventricular dysfunction due to myocarditis, in the setting of a scleroderma renal crisis. The case is particularly intriguing for the favorable outcome of both symptoms and heart function following immunosuppressive therapy. We also highlight the changes observed over time with image techniques as well as in electrocardiograms. Copyright © 2018 Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Retro-aortic, left inferior renal capsular vein

    Directory of Open Access Journals (Sweden)

    Umberto G Rossi

    2015-01-01

    Full Text Available In our case report, abdominal multi-detector computed tomography was used for the pre-operative anatomy evaluation in a living kidney donor. The early phase of the test revealed normal kidneys in the donor. The vascular phase detected a venous variant on the left side: An inferior renal capsular vein, which had a loop and a retro-aortic course. This preoperative knowledge was crucial for the laparoscopic nephrectomy as a surgical procedure for harvesting kidney from the living donor.

  8. Myocardial perfusion in patients with left bundle branch block and without coronary artery disease

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru

    1992-01-01

    For the evaluation of myocardial perfusion in patients with left bundle branch block (LBBB), we performed exercise stress (Ex)-redistribution (RD) myocardial tomography with thallium-201 ( 201 Tl) in 23 patients with LBBB and without coronary artery disease (CAD). Myocardial images in patients with LBBB were compared with those of 9 patients with CAD who showed Ex induced transient septal defect. Bull'-eye maps ( 201 Tl distribution maps at Ex and RD and 201 Tl washout rate [WOR] map) were made from myocardial tomograms. In 23 patients with LBBB, 15 patients (65%) developed myocardial perfusion abnormality. In 10 (67%) of these 15 patients, transient perfusion defect appeared in the entire septum (diffuse type). On the other hand in 5 patients (33%), localized fixed perfusion defect developed at the boundary between septum and anterior wall (focal type). In focal type, every patient had other disease such as hypertension, aortic stenosis or sick sinus syndrome. While in patients with diffuse type, other diseases were observed in 30% (p 201 Tl WOR and 201 Tl uptake ratio of septum to lateral wall indicated that exercise induced septal defect was slighter in diffuse type than CAD. These points might be useful to differentiate whether CAD participates in the septal defect or not in patients with LBBB. (author)

  9. Preserved regulation of renal perfusion pressure by small and intermediate conductance K-Ca channels in hypertensive mice with or without renal failure

    DEFF Research Database (Denmark)

    Waeckel, L.; Bertin, F.; Clavreul, N.

    2015-01-01

    -transgenic female mice expressing human angiotensinogen and renin (AR) genes received either control or a high-salt diet associated to a nitric oxide (NO) synthase inhibitor treatment (BLSL and ARSL). Changes in renal perfusion pressure (RPP) were measured in isolated perfused kidneys. BLSL and AR were moderately...

  10. Computed Tomography Perfusion, Magnetic Resonance Imaging, and Histopathological Findings After Laparoscopic Renal Cryoablation: An In Vivo Pig Model

    DEFF Research Database (Denmark)

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Graumann, Ole

    2017-01-01

    The present study investigates how computed tomography perfusion scans and magnetic resonance imaging correlates with the histopathological alterations in renal tissue after cryoablation. A total of 15 pigs were subjected to laparoscopic-assisted cryoablation on both kidneys. After intervention...... of follow-up, but on microscopic examination, the urothelium was found to be intact in all cases. In conclusion, cryoablation effectively destroyed renal parenchyma, leaving the urothelium intact. Both computed tomography perfusion and magnetic resonance imaging reflect the microscopic findings...

  11. Bioprinting of 3D Convoluted Renal Proximal Tubules on Perfusable Chips

    Science.gov (United States)

    Homan, Kimberly A.; Kolesky, David B.; Skylar-Scott, Mark A.; Herrmann, Jessica; Obuobi, Humphrey; Moisan, Annie; Lewis, Jennifer A.

    2016-10-01

    Three-dimensional models of kidney tissue that recapitulate human responses are needed for drug screening, disease modeling, and, ultimately, kidney organ engineering. Here, we report a bioprinting method for creating 3D human renal proximal tubules in vitro that are fully embedded within an extracellular matrix and housed in perfusable tissue chips, allowing them to be maintained for greater than two months. Their convoluted tubular architecture is circumscribed by proximal tubule epithelial cells and actively perfused through the open lumen. These engineered 3D proximal tubules on chip exhibit significantly enhanced epithelial morphology and functional properties relative to the same cells grown on 2D controls with or without perfusion. Upon introducing the nephrotoxin, Cyclosporine A, the epithelial barrier is disrupted in a dose-dependent manner. Our bioprinting method provides a new route for programmably fabricating advanced human kidney tissue models on demand.

  12. Degree of Left Renal Vein Compression Predicts Nutcracker Syndrome

    Directory of Open Access Journals (Sweden)

    Patrick T. Hangge

    2018-05-01

    Full Text Available Nutcracker syndrome (NS refers to symptomatic compression of the left renal vein (LRV between the abdominal aorta and superior mesenteric artery with potential symptoms including hematuria, proteinuria, left flank pain, and renal venous hypertension. No consensus diagnostic criteria exist to guide endovascular treatment. We aimed to evaluate the specificity of LRV compression to NS symptoms through a retrospective study including 33 NS and 103 control patients. The size of the patent lumen at point of compression and normal portions of the LRV were measured for all patients. Multiple logistic regression analyses (MLR assessing impact of compression, body mass index (BMI, age, and gender on the likelihood of each symptom with NS were obtained. NS patients presented most commonly with abdominal pain (72.7%, followed by hematuria (57.6%, proteinuria (39.4%, and left flank pain (30.3%. These symptoms were more commonly seen than in the control group at 10.6, 11.7, 6.8, and 1.9%, respectively. The degree of LRV compression for NS was 74.5% and 25.2% for controls (p < 0.0001. Higher compression led to more hematuria (p < 0.0013, abdominal pain (p < 0.006, and more proteinuria (p < 0.002. Furthermore, the average BMI of NS patients was 21.4 and 27.2 for controls (p < 0.001 and a low BMI led to more abdominal pain (p < 0.005. These results demonstrate a strong correlation between the degree of LRV compression on imaging in diagnosing NS.

  13. Closed-loop control of renal perfusion pressure in physiological experiments.

    Science.gov (United States)

    Campos-Delgado, D U; Bonilla, I; Rodríguez-Martínez, M; Sánchez-Briones, M E; Ruiz-Hernández, E

    2013-07-01

    This paper presents the design, experimental modeling, and control of a pump-driven renal perfusion pressure (RPP)-regulatory system to implement precise and relatively fast RPP regulation in rats. The mechatronic system is a simple, low-cost, and reliable device to automate the RPP regulation process based on flow-mediated occlusion. Hence, the regulated signal is the RPP measured in the left femoral artery of the rat, and the manipulated variable is the voltage applied to a dc motor that controls the occlusion of the aorta. The control system is implemented in a PC through the LabView software, and a data acquisition board NI USB-6210. A simple first-order linear system is proposed to approximate the dynamics in the experiment. The parameters of the model are chosen to minimize the error between the predicted and experimental output averaged from eight input/output datasets at different RPP operating conditions. A closed-loop servocontrol system based on a pole-placement PD controller plus dead-zone compensation was proposed for this purpose. First, the feedback structure was validated in simulation by considering parameter uncertainty, and constant and time-varying references. Several experimental tests were also conducted to validate in real time the closed-loop performance for stepwise and fast switching references, and the results show the effectiveness of the proposed automatic system to regulate the RPP in the rat, in a precise, accurate (mean error less than 2 mmHg) and relatively fast mode (10-15 s of response time).

  14. Renal versus splenic maximum slope based perfusion CT modelling in patients with portal-hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Michael A. [University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); Karolinska Institutet, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden); Brehmer, Katharina [Karolinska University Hospital Huddinge, Department of Radiology, Stockholm (Sweden); Svensson, Anders; Aspelin, Peter; Brismar, Torkel B. [Karolinska Institutet, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden); Karolinska University Hospital Huddinge, Department of Radiology, Stockholm (Sweden)

    2016-11-15

    To assess liver perfusion-CT (P-CT) parameters derived from peak-splenic (PSE) versus peak-renal enhancement (PRE) maximum slope-based modelling in different levels of portal-venous hypertension (PVH). Twenty-four patients (16 men; mean age 68 ± 10 years) who underwent dynamic P-CT for detection of hepatocellular carcinoma (HCC) were retrospectively divided into three groups: (1) without PVH (n = 8), (2) with PVH (n = 8), (3) with PVH and thrombosis (n = 8). Time to PSE and PRE and arterial liver perfusion (ALP), portal-venous liver perfusion (PLP) and hepatic perfusion-index (HPI) of the liver and HCC derived from PSE- versus PRE-based modelling were compared between the groups. Time to PSE was significantly longer in PVH groups 2 and 3 (P = 0.02), whereas PRE was similar in groups 1, 2 and 3 (P > 0.05). In group 1, liver and HCC perfusion parameters were similar for PSE- and PRE-based modelling (all P > 0.05), whereas significant differences were seen for PLP and HPI (liver only) in group 2 and ALP in group 3 (all P < 0.05). PSE is delayed in patients with PVH, resulting in a miscalculation of PSE-based P-CT parameters. Maximum slope-based P-CT might be improved by replacing PSE with PRE-modelling, whereas the difference between PSE and PRE might serve as a non-invasive biomarker of PVH. (orig.)

  15. Quantitative arterial spin labelling perfusion measurements in rat models of renal transplantation and acute kidney injury at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Zimmer, Fabian; Schad, Lothar R.; Zoellner, Frank G. [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Klotz, Sarah; Hoeger, Simone; Yard, Benito A.; Kraemer, Bernhard K. [Heidelberg Univ., Mannheim (Germany). Dept. of Medicine V

    2017-05-01

    To employ ASL for the measurement of renal cortical perfusion in particular renal disorders typically associated with graft loss and to investigate its potential to detect and differentiate the related functional deterioration i.e., in a setting of acute kidney injury (AKI) as well as in renal grafts showing acute and chronic transplant rejection. 14 Lewis rats with unilateral ischaemic AKI and 43 Lewis rats with renal grafts showing acute or chronic rejections were used. All ASL measurements in this study were performed on a 3 T MR scanner using a FAIR True-FISP approach to assess renal blood flow (RBF). Perfusion maps were calculated and the cortical blood flow was determined using a region-of-interest based analysis. RBF of healthy and AKI kidneys as well as of both rejection models, were compared. In a subsample of 20 rats, creatinine clearance was measured and correlated with cortical perfusion. RBF differs significantly between healthy and AKI kidneys (P < 0.001) with a mean difference of 213 ± 80 ml/100 g/min. Renal grafts with chronic rejections show a significantly higher (P < 0.001) mean cortical perfusion (346 ± 112 ml/100 g/min) than grafts with acute rejection (240 ± 66 ml/100 g/min). Both transplantation models have a significantly (P < 0.001) lower perfusion than healthy kidneys. Renal creatinine clearance is significantly correlated (R = 0.85, P < 0.001) with cortical blood flow. Perfusion measurements with ASL have the potential to become a valuable diagnostic tool, regarding the detection of renal impairment and the differentiation of disorders that lead to a loss of renal function and that are typically associated with graft loss.

  16. Quantitative arterial spin labelling perfusion measurements in rat models of renal transplantation and acute kidney injury at 3 T

    International Nuclear Information System (INIS)

    Zimmer, Fabian; Schad, Lothar R.; Zoellner, Frank G.; Klotz, Sarah; Hoeger, Simone; Yard, Benito A.; Kraemer, Bernhard K.

    2017-01-01

    To employ ASL for the measurement of renal cortical perfusion in particular renal disorders typically associated with graft loss and to investigate its potential to detect and differentiate the related functional deterioration i.e., in a setting of acute kidney injury (AKI) as well as in renal grafts showing acute and chronic transplant rejection. 14 Lewis rats with unilateral ischaemic AKI and 43 Lewis rats with renal grafts showing acute or chronic rejections were used. All ASL measurements in this study were performed on a 3 T MR scanner using a FAIR True-FISP approach to assess renal blood flow (RBF). Perfusion maps were calculated and the cortical blood flow was determined using a region-of-interest based analysis. RBF of healthy and AKI kidneys as well as of both rejection models, were compared. In a subsample of 20 rats, creatinine clearance was measured and correlated with cortical perfusion. RBF differs significantly between healthy and AKI kidneys (P < 0.001) with a mean difference of 213 ± 80 ml/100 g/min. Renal grafts with chronic rejections show a significantly higher (P < 0.001) mean cortical perfusion (346 ± 112 ml/100 g/min) than grafts with acute rejection (240 ± 66 ml/100 g/min). Both transplantation models have a significantly (P < 0.001) lower perfusion than healthy kidneys. Renal creatinine clearance is significantly correlated (R = 0.85, P < 0.001) with cortical blood flow. Perfusion measurements with ASL have the potential to become a valuable diagnostic tool, regarding the detection of renal impairment and the differentiation of disorders that lead to a loss of renal function and that are typically associated with graft loss.

  17. Myocardial perfusion SPECT in a case of retropulmonary looping of left coronary artery in a baby after arterial switch surgery

    International Nuclear Information System (INIS)

    Padma, Subramanyam; Sundaram, Palaniswamy Shanmuga

    2014-01-01

    Pediatric myocardial perfusion imaging (MPI) is not a routine investigation in an Indian setting due to under referrals and logistic problems. However, MPI is a frequently performed and established modality of investigation in adults for the identification of myocardial ischemia and viability. We report myocardial perfusion scintigraphy in a case of retropulmonary looping of left coronary artery in a baby after arterial switch surgery. Adenosine stress MPI revealed a large infarct involving anterior segment with moderate reversible ischemia of the lateral left ventricular segment. Coronary angiogram later confirmed left main coronary artery ostial occlusion with retrograde collateral supply from dilated right coronary artery

  18. Validation of a model of left ventricular segmentation for interpretation of SPET myocardial perfusion images

    International Nuclear Information System (INIS)

    Aepfelbacher, F.C.; Johnson, R.B.; Schwartz, J.G.; Danias, P.G.; Chen, L.; Parker, R.A.; Parker, A.J.

    2001-01-01

    Several models of left ventricular segmentation have been developed that assume a standard coronary artery distribution, and are currently used for interpretation of single-photon emission tomography (SPET) myocardial perfusion imaging. This approach has the potential for incorrect assignment of myocardial segments to vascular territories, possibly over- or underestimating the number of vessels with significant coronary artery disease (CAD). We therefore sought to validate a 17-segment model of myocardial perfusion by comparing the predefined coronary territory assignment with the actual angiographically derived coronary distribution. We examined 135 patients who underwent both coronary angiography and stress SPET imaging within 30 days. Individualized coronary distribution was determined by review of the coronary angiograms and used to identify the coronary artery supplying each of the 17 myocardial segments of the model. The actual coronary distribution was used to assess the accuracy of the assumed coronary distribution of the model. The sensitivities and specificities of stress SPET for detection of CAD in individual coronary arteries and the classification regarding perceived number of diseased coronary arteries were also compared between the two coronary distributions (actual and assumed). The assumed coronary distribution corresponded to the actual coronary anatomy in all but one segment (3). The majority of patients (80%) had 14 or more concordant segments. Sensitivities and specificities of stress SPET for detection of CAD in the coronary territories were similar, with the exception of the RCA territory, for which specificity for detection of CAD was better for the angiographically derived coronary artery distribution than for the model. There was 95% agreement between assumed and angiographically derived coronary distributions in classification to single- versus multi-vessel CAD. Reassignment of a single segment (segment 3) from the LCX to the LAD

  19. Validation of a model of left ventricular segmentation for interpretation of SPET myocardial perfusion images

    Energy Technology Data Exchange (ETDEWEB)

    Aepfelbacher, F.C.; Johnson, R.B.; Schwartz, J.G.; Danias, P.G. [Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA (United States); Chen, L.; Parker, R.A. [Biometrics Center, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA (United States); Parker, A.J. [Nuclear Medicine Division, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA (United States)

    2001-11-01

    Several models of left ventricular segmentation have been developed that assume a standard coronary artery distribution, and are currently used for interpretation of single-photon emission tomography (SPET) myocardial perfusion imaging. This approach has the potential for incorrect assignment of myocardial segments to vascular territories, possibly over- or underestimating the number of vessels with significant coronary artery disease (CAD). We therefore sought to validate a 17-segment model of myocardial perfusion by comparing the predefined coronary territory assignment with the actual angiographically derived coronary distribution. We examined 135 patients who underwent both coronary angiography and stress SPET imaging within 30 days. Individualized coronary distribution was determined by review of the coronary angiograms and used to identify the coronary artery supplying each of the 17 myocardial segments of the model. The actual coronary distribution was used to assess the accuracy of the assumed coronary distribution of the model. The sensitivities and specificities of stress SPET for detection of CAD in individual coronary arteries and the classification regarding perceived number of diseased coronary arteries were also compared between the two coronary distributions (actual and assumed). The assumed coronary distribution corresponded to the actual coronary anatomy in all but one segment (3). The majority of patients (80%) had 14 or more concordant segments. Sensitivities and specificities of stress SPET for detection of CAD in the coronary territories were similar, with the exception of the RCA territory, for which specificity for detection of CAD was better for the angiographically derived coronary artery distribution than for the model. There was 95% agreement between assumed and angiographically derived coronary distributions in classification to single- versus multi-vessel CAD. Reassignment of a single segment (segment 3) from the LCX to the LAD

  20. The application of phase analysis of gated myocardial perfusion imaging to assess left ventricular mechanical dyssynchrony in cardiovascular disease

    International Nuclear Information System (INIS)

    Wang Jianfeng; Wang Yuetao

    2013-01-01

    Left ventricular mechanical dyssynchrony is closely related to the severity of cardiovascular disease, it is essential to assess left ventricular mechanical dyssynchrony accurately for early prediction of adverse cardiac events and prognosis assessment of the cardiac resynchronization therapy. As a new technology to assess left ventricular mechanical dyssynchrony, the phase analysis of gated myocardial perfusion imaging (GMPI) can get both quantitative indicators of regional myocardial perfusion, evaluation of regional myocardial viability and scar tissue, as well as quantitative analysis of left ventricular function and left ventricular mechanical synchrony, it has broad application prospects in cardiovascular disease to assess left ventricular mechanical dyssynchrony and prognosis assessment. This review mainly described the applications of GMPI phase analysis in the cardiovascular disease. (authors)

  1. Early post transplantation renal allograft perfusion failure due to intimal dissection of the renal artery

    Directory of Open Access Journals (Sweden)

    Khattab Omar

    2009-01-01

    Full Text Available Transplant renal artery stenosis (TRAS is a recognized and potentially curable cause of post transplant arterial hypertension, allograft dysfunction, and graft loss. It usually occurs 3 months to 2 years after transplantation, but early or later presentations are not uncommon. We present a case of renal artery narrowing due to intimal dissection that was managed medically.

  2. Important parameters in the detection of left main trunk disease using stress myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Shiba, Chie; Chikamori, Taishiro; Hida, Satoshi

    2009-01-01

    We sought noninvasively to diagnose left main trunk (LMT) disease using myocardial perfusion imaging (MPI). Five hundred and eight patients with suspected coronary artery disease (CAD) underwent both stress MPI and coronary angiography. The extent and severity of perfusion abnormalities were assessed using a 20-segment model. In addition, perfusion defects in both left anterior descending and left circumflex arterial territories were defined as a left main (LM) pattern defect, and those in 3-coronary arterial territories as a 3-vessel pattern defect. In 42 patients with LMT disease, a summed stress score (19.4±10.0 vs. 13.5±10.0; p<0.0001) and a summed rest score (12.1±9.7 vs. 7.0±7.8; p=0.002) were greater than in 466 patients without LMT disease, while a summed difference score was similar (7.3±7.7 vs. 6.5±6.1; p=NS). The prevalence of an LM-pattern defect was low in both groups (12% vs. 8%; p=NS). However, a 3-vessel pattern defect (33% vs. 7%; p<0.0001), lung uptake of radiotracers (38% vs. 11%; p<0.0001), and transient ischemic dilation (31% vs. 13%; p=0.003) were more frequently observed in patients with LMT disease than in those without. Logistic regression analysis showed that a 3-vessel pattern defect (odds ratio (OR)=3.5, 95% confidence interval (CI)=1.4-8.8; p=0.007), lung uptake of radiotracers (OR=2.5, 95% CI=1.1-5.7; p=0.03), and previous myocardial infarction (MI) (OR=2.4, 95% CI=1.0-5.7; p=0.05) were the most important parameters to detect LMT disease. After excluding 163 patients with previous MI, a repeat analysis revealed that lung uptake of radiotracers (OR=8.2, 95% CI=2.3-29.2; p=0.001) and an LM-pattern defect (OR=6.3, 95% CI=1.4-27.2; p<0.02) were independent predictors for LMT disease. In the identification of LMT disease, lung uptake of radiotracers was a single best parameter, which was independent of the presence or absence of previous MI. (author)

  3. 50 Years of renal physiology from one man and the perfused tubule: Maurice B. Burg.

    Science.gov (United States)

    Hamilton, Kirk L; Moore, Antoni B

    2016-08-01

    Technical advancements in research techniques in science are made in slow increments. Even so, large advances from insight and hard work of an individual with a single technique can have astonishing ramifications. Here, we examine the impact of Dr. Maurice B. Burg and the isolated perfused renal tubule technique and celebrate the 50th anniversary of the publication by Dr. Burg and his colleagues of their landmark paper in the American Journal of Physiology in 1966. In this study, we have taken a scientific visualization approach to study the scientific contributions of Dr. Burg and the isolated perfused tubule preparation as determining research impact by the number of research students, postdoctoral fellows, visiting scientists, and national and international collaborators. Additionally, we have examined the research collaborations (first and second generation scientists), established the migrational visualization of the first generation scientists who worked directly with Dr. Burg, quantified the metrics indices, identified and quantified the network of coauthorship of the first generation scientists with their second generation links, and determined the citations analyses of outputs of Dr. Burg and/or his first generation collaborators as coauthors. We also review the major advances in kidney physiology that have been made with the isolated perfused tubule technique. Finally, we are all waiting for the discoveries that the isolated perfused preparation technique will bring during the next 50 years. Copyright © 2016 the American Physiological Society.

  4. Recombinant erythropoietin acutely decreases renal perfusion and decouples the renin-angiotensin-aldosterone system.

    Science.gov (United States)

    Aachmann-Andersen, Niels J; Christensen, Soren J; Lisbjerg, Kristian; Oturai, Peter; Johansson, Pär I; Holstein-Rathlou, Niels-Henrik; Olsen, Niels V

    2018-03-01

    The effect of recombinant erythropoietin (rhEPO) on renal and systemic hemodynamics was evaluated in a randomized double-blinded, cross-over study. Sixteen healthy subjects were tested with placebo, or low-dose rhEPO for 2 weeks, or high-dose rhEPO for 3 days. Subjects refrained from excessive salt intake, according to instructions from a dietitian. Renal clearance studies were done for measurements of renal plasma flow, glomerular filtration rate (GFR) and the segmentel tubular handling of sodium and water (lithium clearance). rhEPO increased arterial blood pressure, total peripheral resistance, and renal vascular resistance, and decreased renal plasma flow in the high-dose rhEPO intervention and tended to decrease GFR. In spite of the decrease in renal perfusion, rhEPO tended to decrease reabsorption of sodium and water in the proximal tubule and induced a prompt decrease in circulating levels of renin and aldosterone, independent of changes in red blood cell mass, blood volumes, and blood pressure. We also found changes in biomarkers showing evidence that rhEPO induced a prothrombotic state. Our results suggest that rhEPO causes a direct downregulation in proximal tubular reabsorption that seems to decouple the activity of the renin-angiotensin-aldosterone system from changes in renal hemodynamics. This may serve as a negative feed-back mechanism on endogenous synthesis of EPO when circulating levels of EPO are high. These results demonstrates for the first time in humans a direct effect of rhEPO on renal hemodynamics and a decoupling of the renin-angiotensin-aldosterone system. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  5. The value of the renal resistive index in the measurement of renal perfusion before and after extracorporal shock wave lithotripsy in correlation to the scintigraphy, to the magnetic resonance perfusion imaging and to big-endothelin values

    International Nuclear Information System (INIS)

    Palwein-Prettner, L.

    1999-07-01

    Purpose: the goal of this study was to evaluate effects of extracorporeal shock wave lithotripsy (ESWL) on the renal perfusion using the resistive index (RI), perfusion scintigraphy, magnetic resonance (MR) perfusion imaging and plasma big-endothelin (big-ET-1) values. Method/materials: In 21 patients divided in 3 age-groups the RI was measured before and 1,3,6 and 24 hours after ESWL. Big-ET-1, a potent vasoconstrictor peptid was correlated with the RI values. The RI and Big-ET-1 results was compared to the results of the MR perfusion imaging and the scintigraphy, the gold-standard method. Results: The RI of the treated kidneys increased significantly from 0,64±0,05 to 0,72±0,08 after the ESWL (p<0,001) and in the untreated kidneys from 0,63±0,05 to 0,68±0,09 (p=0,003). The hightest age group shows the most significant increase. The Big-ET-values also increased only in this age group significantly from 0,78±0,24 fmol/l to 1,58±0,52 fmol/l. In the scintigraphy the decrease of the renal plasma flow (RPF) in this age group was most significant. The MR perfusion Imaging shows in all age groups significant decrease (p<0,001). Conclusion: we conclude that the ESWL causes considerable renal parenchymal damage only in the elderly patients. The following changes in renal perfusion were measured very sensitively with the RI which had a good correlation to the results of the perfusion scintigraphy and the MR perfusion imaging. Further studies with larger series have to evaluate these results. (author)

  6. Usefulness of {sup 201}Tl myocardial perfusion SPECT in prediction of left ventricular remodeling following an acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seok Nam; Park, C. H.; Hwang, Kyung Hoon [Ajou Univ. College of Medicine, Suwon (Korea, Republic of)

    2000-02-01

    We investigated the role of myocardial perfusion SPECT in prediction of ventricular dilatation and the role of revascularization including thrombolytic therapy and PTCA in prevention of ventricular dilatation after an acute myocardial linfarction (AMI). We performed dipyridamole stress, 4 hour redistribution, and 24 hour reinjection Tl-201 SPECT in 6 patients with AMI two to nine days after attack. Perfusion and wall motion abnormalities were quantified by perfusion index(PI) and wall motion index (WMI). Left ventricular ejection fraction (LVEF), WMI and ventricular volume were measured within 1 week of AMI and after average of 6 months. According to serial changes of left ventricular end-diastolic volume (LVEDV), patients were divided into two groups. We compared WMI, PI and LVEF between the two groups. Relationships among degree of volume, stress-rest PI, WMI, CKMB,Q wave, LVEF and revascularization were analysed using multivariate analysis. Only initial rest perfusion index was significantly different between the two groups (p<0.05). While initial LVEF, stress PI, CKMB, trial of revascularization procedure, presence of Q wave and WMI were not significantly different between the two groups. Eight of 16 patients (50%) showed LV dilatation on follow-up echocardiography. Three of 3 patients (100%) who did not undergo revascualrization procedure documented LV dilatation. And only 5 (38%) of the remaining 13 patients who underwent revascularization revealed LV dilatation. There was no difference in infarct location between the two groups. By multivariate linear regression analysis in patients only undergoing revascularization, rest perfusion index was the only significant factor. Myocardial perfusion SPECT performed prior to revascularization was useful in prediction of LV dilatation after an AMI. Rest perfusion index on myocardial perfusion plays as a significant predictor of left ventricular dilatation after AMI. And revascularization appears to be a valuable

  7. The investigation of in-vivo measurement of individual renal blood perfusion, effective renal plasma flow and quantitation of renogram and 15 min bladder collection percentage

    International Nuclear Information System (INIS)

    Huang Kangchu

    1991-01-01

    25 normals and 43 renal diseases were examined by the RBF-I multifunctioning renography. The result showed that the determination of ERPF has no difference between blood sampling and noin-blood sampling method, and actually the lattrer can replace the former one. Above method can be also used for the measurement of the individual renal blood perfusion, the quantitation of renogram and the 15 min bladder coolection percentage at the same time. Thereby it provides more complete diagnostic information for the renal vascular diseases, renal pancren chymations and other urologic diseases

  8. Ex Vivo Normothermic Perfusion Induces Donor-Derived Leukocyte Mobilization and Removal Prior to Renal Transplantation

    Directory of Open Access Journals (Sweden)

    John P. Stone

    2016-11-01

    Discussion: We demonstrate that ex vivo normothermic perfusion initiates an inflammatory cytokine storm and release of mitochondrial and genomic DNA. This is likely to be responsible for immune cell activation and mobilization into the circuit prior to transplantation. Interestingly this did not have an impact on renal function. These data therefore suggest that normothermic perfusion can be used to immunodeplete and to saturate the pro-inflammatory capacity of donor kidneys prior to transplantation.

  9. Renal Cell Carcinoma Perfusion before and after Radiofrequency Ablation Measured with Dynamic Contrast Enhanced MRI: A Pilot Study.

    Science.gov (United States)

    Wah, Tze Min; Sourbron, Steven; Wilson, Daniel Jonathan; Magee, Derek; Gregory, Walter Martin; Selby, Peter John; Buckley, David L

    2018-01-08

    To investigate if the early treatment effects of radiofrequency ablation (RFA) on renal cell carcinoma (RCC) can be detected with dynamic contrast enhanced (DCE)-MRI and to correlate RCC perfusion with RFA treatment time. 20 patients undergoing RFA of their 21 RCCs were evaluated with DCE-MRI before and at one month after RFA treatment. Perfusion was estimated using the maximum slope technique at two independent sittings. Total RCC blood flow was correlated with total RFA treatment time, tumour location, size and histology. DCE-MRI examinations were successfully evaluated for 21 RCCs (size from 1.3 to 4 cm). Perfusion of the RCCs decreased significantly ( p measuring RCC perfusion before and after RFA. Perfusion significantly decreases in the zone of ablation, suggesting that it may be useful for the assessment of treatment efficacy. Pre-RFA RCC blood flow may be used to predict RFA treatment time.

  10. [Acute stent thrombosis and reverse transient left ventricular dilatation after performing a single-photon emission computed tomography myocardial perfusion].

    Science.gov (United States)

    Miranda, B; Pizzi, M N; Aguadé-Bruix, S; Domingo, E; Candell-Riera, J

    2015-01-01

    A 63-year-old male patient with a history of stent implantation in the left anterior descending three months before. Due to the presentation of vegetative symptoms, he was referred for gated-SPECT myocardial perfusion. During acquisition of the resting images he presented chest pain and ST segment elevation, so that urgent cardiac catheterization was performed, showing stent thrombosis. Rest perfusion imaging showed a defect in anterior and apical perfusion, more severe and extensive than in the stress images, with striking left ventricular dilatation and a fall in the ejection fraction related to the acute ischemia phenomenon. Intense exercise is associated with a transient activation of the coagulation system and hemodynamic changes that might induce thrombosis, especially in recently implanted coronary stents that probably still have not become completely endothelialized. Copyright © 2014 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  11. A unique case of bifid left testicular artery having its anomalous high origin from renal artery

    Directory of Open Access Journals (Sweden)

    Ashwini P Aithal

    2016-01-01

    Full Text Available The testicular arteries are known to originate from the ventrolateral aspect of the abdominal aorta and descend obliquely to the pelvic cavity and supply the testis. An anatomical description of an uncommon variation of the left testicular artery is presented in this case report, highlighting its clinical implications. During routine dissection of a male cadaver, we found that the left testicular artery was bifid and it was arising from the left renal artery. After its origin, it then coursed behind the left renal vein, passed between the left testicular vein and left ureter and at the lower pole of the left kidney, this bifid testicular artery joined to form a single testicular artery which thereafter presented a normal course. Anatomy of the testicular artery has been studied in detail because of its importance in testicular physiology, as well as its significance in testicular and renal surgery. This vascular variation shows a major significance in renal surgery, partial or total nephrectomy, and renal transplant. In addition, this anatomical variation enhances the importance of arteriography or the Doppler ultrasound examination of the renal hilum before surgeries.

  12. Quantification of left ventricular regional functions using ECG-gated myocardial perfusion SPECT. Validation of left ventricular systolic functions

    International Nuclear Information System (INIS)

    Yamamoto, Akira; Takahashi, Naoto; Iwahara, Shin-ichiro; Munakata, Kazuo; Hosoya, Tetsuo

    2006-01-01

    We have developed a program to quantify regional left ventricular (LV) function and wall motion synchrony using electrocardiogram (ECG)-gated myocardial perfusion SPECT (MPS). This preliminary study was undertaken to validate the use of this program for estimating regional LV systolic function. Patients were subjected to MPS by 99m Tc-sestamibi at rest. The study included 20 patients who were confirmed to have a low probability of coronary artery disease (LPG; low probability group), 19 heart disease patients who were examined by MPS and equilibrium radionuclide angiography (ERNA) (ERG; ERNA group), and 24 patients who were examined by MPS and 2-dimensional echocardiography (2DE) (2DEG; 2DE group). The values of the ejection fraction (EF) and peak ejection rate (PER) were estimated. The global functions evaluated by this program were compared with those obtained by ERNA in the ERG. For regional assessment, the reference values of the functional indices were obtained for 17 LV segments in LPG. The Z score, (reference average value of the segment-patient's value of the segment)/reference standard deviation of the segment, was used for the evaluation of regional functions; a score equal to or greater than 2 was defined as abnormal. Semiquantitative visual interpretation of 2DE was used as the standard to assess wall motion. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of these criteria and the relationship between 2DE grading and Z scoring were validated in 2DEG. The values of the global EF and PER evaluated by this program correlated with those determined by ERNA (r=0.76 and 0.58, respectively; p -10 ). The potential of this program to quantify the regional systolic function was validated. (author)

  13. Effect of radiographic contrast media on renal perfusion - First results.

    Science.gov (United States)

    Lamby, P; Jung, F; Falter, J; Mrowietz, C; Graf, S; Schellenberg, L; Platz Batista da Silva, N; Prantl, L; Franke, R P; Jung, E M

    2016-01-01

    Intra-arterial administration of radiographic contrast media (CM) is discussed to impair renal perfusion. The pathogenesis of contrast-induced Nephropathy (CIN) is still not clarified. This trial was performed to prove the effects of two CM with different molecular structure on renal perfusion. A prospective, randomized study on 16 pigs was designed to compare the outcome after application of a low-osmolar iodinated CM (770 mOsm/kg H2O - Group1) and an iso-osmolar iodinated CM (290 mOsm/kg H2o - Group2).Color Coded Doppler Sonography (LOGIQ E9, GE, Milwaukee, USA) was applied for measuring the Renal Resistive Index (RRI) before and after the first, fifth, and tenth bolus of CM. Statistics was performed using analysis of variance for repeated measurements with the Factor "CM". All flow spectra were documented free of artifacts and Peak Systolic Velocity (PSV), Enddiastolic Velocity (EDV) and RRI respectively could be calculated. Mean PSV in Group 1 led to a decrease while in Group 2 PSV showed a significant increase after CM (p = 0,042). The course of the mean EDV in both groups deferred accordingly (p = 0,033). Mean RRI over time significantly deferred in both groups (p = 0,001). It showed a biphasic course in Group 2 and a decrease over time in Group 2. While iso-osmolar CM induced an increase of PSV and EDV together with a decrease of RRI, low-osmolar CM could not show this effect or rather led to the opposite.

  14. Endovascular management of recurrent stenosis following left renal vein transposition for the treatment of Nutcracker syndrome.

    Science.gov (United States)

    Baril, Donald T; Polanco, Patricio; Makaroun, Michel S; Chaer, Rabih A

    2011-04-01

    Nutcracker syndrome is an entity resulting from left renal vein compression by the superior mesenteric artery and the aorta, leading to symptoms of left flank pain and hematuria. Conventional treatment has been surgical, commonly through transposition of the left renal vein to a more caudal location on the inferior vena cava. Additionally, endovascular approaches, primarily via renal vein stenting, have been described for treatment of this syndrome. We report the case of a patient with Nutcracker syndrome who underwent successful left renal vein transposition but then developed recurrent symptoms 10 months postoperatively and was successfully treated with angioplasty and stenting. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  15. Myocardial perfusion changes in patients irradiated for left-sided breast cancer and correlation with coronary artery distribution

    International Nuclear Information System (INIS)

    Lind, Pehr A.; Pagnanelli, Robert; Marks, Lawrence B.; Borges-Neto, Salvador; Hu, Caroline; Zhou, S.-M.; Light, Kim; Hardenbergh, Patricia H.

    2003-01-01

    Purpose: To evaluate postradiation regional heart perfusion changes with single photon emission tomography (SPECT) myocardial perfusion imaging in 69 patients treated with tangential photon beams radiation therapy (RT) for left-sided breast cancer. To correlate SPECT changes with percent irradiated left ventricle (LV) volume and risk factors for coronary artery disease (CAD). Methods and Materials: Rest SPECT of the LV was acquired pre-RT and at 6-month intervals post-RT. The extent of defects (%) with a severity > 1.5 standard deviations below the mean was quantitatively analyzed for the distributions of the left anterior descending (LAD) artery, left circumflex (LCX) artery, and right coronary artery (RCA) based on computer assisted polar map reconstruction (i.e., bull's-eye-view). Changes in perfusion were correlated with percent irradiated LV receiving > 25 Gy (range 0-32%). Data on patient- and treatment-related factors were collected prospectively (e.g., cardiac premorbidity, risk factors for CAD, chemotherapy, and hormonal treatment). Results: In the LAD distribution, there were increased perfusion defects at 6 months (median 11%; interquartile range 2-23) compared with baseline (median 5%; interquartile range 1-14) (p<0.001). There were no increases in perfusion defects in the LCX or RCA distributions. In multivariate analysis, the SPECT perfusion changes in the LAD distribution at 6 months were independently associated with percent irradiated LV (p<0.001), hormonal therapy (p=0.005), and pre-RT hypercholesterolemia (p=0.006). The SPECT defects in the LAD distribution at 12 and 18 months were not statistically different from those at 6 months. The perfusion defects in the LAD distribution were limited essentially to the regions of irradiated myocardium. Conclusion: Tangential photon beam RT in patients with left-sided breast cancer was associated with short-term SPECT defects in the vascular distribution corresponding to the radiation portals. Factors

  16. Retro-aortic left renal vein--an anatomic variation description and review of literature.

    Science.gov (United States)

    Suma, H Yekappa; Roopa, Kulkarni

    2011-01-01

    This study reports the presence of a retro-aortic renal vein on the left side draining into the inferior vena cava. This variation was observed during routine dissection in a female cadaver aged about 55 years. This variation is of importance because of its implications in renal transplantation, renal surgery, vascular surgery, uroradiology and gonadal surgeries. The knowledge of such variations can help the clinicians for its recognition and protection.

  17. Dynamic renal transplant imaging with /sup 99m/Tc DTPA (Sn) supplemented by a transplant perfusion index in the management of renal transplants

    International Nuclear Information System (INIS)

    Hilson, A.J.W.; Maisey, M.N.; Brown, C.B.; Ogg, C.S.; Bewick, M.S.

    1978-01-01

    We have performed 955 studies on 152 patients with 167 renal transplants. Images were recorded following bolus injection of 12 to 15 mCi Tc-99m DTPA (Sn). The data were stored on a computer and analyzed by generation of region-of-interest curves from (a) the iliac artery distal to the transplant, (b) the kidney, and (c) a background area. A perfusion index was adopted: arterial counts per cell, integrated to peak/concurrent renal counts per cell x 100. In 276 studies the patient clearly had acute tubular necrosis (ATN), rejection, or a normal kidney on retrospective analysis. The normal perfusion index has a value below 150, and it increases with falling perfusion, such as is seen in rejection and in renal-artery stenosis. The use of this index in addition to sequential images and changes in the region-of-interest curves usually allows separation of rejection from ATN and, particularly, rejection from normals. When serial studies are performed, the separation of rejecting from nonrejecting transplants is excellent, although renal-artery stenosis may cause similar changes in perfusion

  18. Assessment of renal perfusion with contrast-enhanced ultrasound: Preliminary results in early diabetic nephropathies.

    Science.gov (United States)

    Dong, Yi; Wang, Wen-Ping; Lin, Pan; Fan, Peili; Mao, Feng

    2016-01-01

    We performed a prospective study to evaluate the value of contrast-enhanced ultrasound (CEUS) in quantitative evaluation of renal cortex perfusion in patients suspected of early diabetic nephropathies (DN), with the estimated GFR (MDRD equation) as the gold standard. The study protocol was approved by the hospital review board; each patient gave written informed consent. Our study included 46 cases (21 males and 25 females, mean age 55.6 ± 4.14 years) of clinical confirmed early DN patients. After intravenous bolus injection of 1 ml sulfur hexafluoride microbubbles of ultrasound contrast agent, real time CEUS of renal cortex was performed successively using a 2-5 MHz convex probe. Time-intensity curves (TICs) and quantitative indexes were created with Qlab software. Receiver operating characteristic (ROC) curves were used to predict the diagnostic criteria of CEUS quantitative indexes, and their diagnostic efficiencies were compared with resistance index (RI) and peak systolic velocity (PSV) of renal segmental arteries by chi square test. Our control group included forty-five healthy volunteers. Difference was considered statistically significant with P  0.05). CEUS might be helpful to improve early diagnosis of DN by quantitative analyses. AUC and DPI might be valuable quantitative indexes.

  19. Myocardial perfusion SPECT for assessment of left ventricular function and volume- comparison with echocardiography

    International Nuclear Information System (INIS)

    Cheng Xu; Huang Gang

    2004-01-01

    Objective: The purpose of this study was to evaluate left ventricular volume and function by gated SPECT and comparison of the results with echocardiography. Methods: 65 Consecutive patients (49 male, 16 female; mean age 61+11 years) who underwent both gated 99m Tc-MIBI myocardial perfusion SPECT and echocardiography within a 15 days period were included in the study. Exclusion criteria were any change in clinical status between acquisition of the gated SPECT and echocardiography studies, acute myocardial infarction occurring less than 7 days before study, and surgical procedures occurring within 30 days of the study. The clinical diagnosis of each patient was not considered, as this was not relevant to the purpose of the study. The diagnoses were as follows: coronary artery disease (n=46), hypertensive heart disease (n=8), old myocardial infarction (n=5), myocarditis (n=2), and routine medical examination(n=4). A dose of 740 MBq of 99 Tc m -sestamibi was administered in resting condition. Gated SPECT images were obtained with ADAC Vertex MCD-AC SPECT system. The raw projection images were reconstructed with filtered back-projection (ramp filter), without attenuation correction. The data, including left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV) were obtained using AUTOQUANT software (ADAC corporation). The echocardiography study used its standard techniques. Two nuclear medicine physicians processed the raw images respectively to evaluate internal reproducibility of gated SPECT. In order to compare the results of gated SPECT with echocardiography on different left ventricular volumes, all patients were divided into two groups (EDV 90 ml, n=34) based by EDV measurements in echocardiography. Results: The correlation coefficient of LVEF, EDV, ESV between SPECT and echocardiography were 0.77, 0.86 and 0.90 respectively. P 0.07). The reproducibility of gated SPECT was excellent. There were no significant differences in

  20. Cardiac risk stratification with myocardial perfusion imaging in potential renal-pancreas transplant recipients

    International Nuclear Information System (INIS)

    McCarthy, M.C.; Larcos, G.; Chapman, J.

    1998-01-01

    Full text: Combined renal/pancreas transplantation is used in patients with severe type-1 diabetes and renal failure. Many patients have asymptomatic coronary artery disease (CAD). Thus, myocardial perfusion imaging (MPI) is widely used for preoperative risk assessment, however, its value has recently been challenged. The purpose of this study was to determine the predictive value of MPI compared to coronary angiography and/or thirty day perioperative cardiac events (cardiac death, myocardial infarction and unstable angina). We reviewed the MPI in 132 patients that were referred for possible renal pancreas transplantation during the period between 1987 - June 1997. Fifty five patients were excluded because of: still awaiting transplantation (n=19) ongoing medical assessment (n=21), received kidney only transplant (n=6) or other factors (n=9). Thus, 77 patients form the basis of this report. Seventy one patients were transplanted, 5 had coronary angiography and one died before transplantation but with coronary anatomy defined at autopsy. All patients (39 male, 38 female; mean age 37 years) had Tl-201 or Tc-99m MIBI SPECT at Westmead (n=54) or elsewhere (n=23). Patients underwent MPI, a mean of 12.1 months before transplantation and a mean of 6 months before coronary angiography or autopsy. MPI was normal in 64 (83%) and abnormal in 13 (17%) patients. Of the abnormal MPI, 7 patients had CAD and one had unstable angina post-operatively (PPV = 8/13; 61%). One patient had a fixed defect post CABG but proceeded to transplant with-out event; the other 4 patients had normal coronary anatomy. Of the normal MPIs there were no transplant related cardiac events, but one patient required CABG >12 months post MPI and a further patient died >12 months post transplant and was shown to have CAD at autopsy (NPV=62/64;97%). In conclusion we have found an excellent NPV and an acceptable PPV for MPI in potential renal pancreas graft recipients

  1. Cardiac risk stratification with myocardial perfusion imaging in potential renal-pancreas transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    McCarthy, M.C.; Larcos, G.; Chapman, J. [Westmead Hospital, Westmead, Sydney, NSW (Australia). Departments of Nuclear Medicine and Ultrasound

    1998-06-01

    Full text: Combined renal/pancreas transplantation is used in patients with severe type-1 diabetes and renal failure. Many patients have asymptomatic coronary artery disease (CAD). Thus, myocardial perfusion imaging (MPI) is widely used for preoperative risk assessment, however, its value has recently been challenged. The purpose of this study was to determine the predictive value of MPI compared to coronary angiography and/or thirty day perioperative cardiac events (cardiac death, myocardial infarction and unstable angina). We reviewed the MPI in 132 patients that were referred for possible renal pancreas transplantation during the period between 1987 - June 1997. Fifty five patients were excluded because of: still awaiting transplantation (n=19) ongoing medical assessment (n=21), received kidney only transplant (n=6) or other factors (n=9). Thus, 77 patients form the basis of this report. Seventy one patients were transplanted, 5 had coronary angiography and one died before transplantation but with coronary anatomy defined at autopsy. All patients (39 male, 38 female; mean age 37 years) had Tl-201 or Tc-99m MIBI SPECT at Westmead (n=54) or elsewhere (n=23). Patients underwent MPI, a mean of 12.1 months before transplantation and a mean of 6 months before coronary angiography or autopsy. MPI was normal in 64 (83%) and abnormal in 13 (17%) patients. Of the abnormal MPI, 7 patients had CAD and one had unstable angina post-operatively (PPV = 8/13; 61%). One patient had a fixed defect post CABG but proceeded to transplant with-out event; the other 4 patients had normal coronary anatomy. Of the normal MPIs there were no transplant related cardiac events, but one patient required CABG >12 months post MPI and a further patient died >12 months post transplant and was shown to have CAD at autopsy (NPV=62/64;97%). In conclusion we have found an excellent NPV and an acceptable PPV for MPI in potential renal pancreas graft recipients

  2. Assessment of left ventricular function and volumes by myocardial perfusion scintigraphy - comparison of two algorithms

    International Nuclear Information System (INIS)

    Zajic, T.; Fischer, R.; Brink, I.; Moser, E.; Krause, T.; Saurbier, B.

    2001-01-01

    Aim: Left ventricular volume and function can be computed from gated SPECT myocardial perfusion imaging using emory cardiac toolbox (ECT) or gated SPECT quantification (GS-Quant). The aim of this study was to compare both programs with respect to their practical application, stability and precision on heart-models as well as in clinical use. Methods: The volumes of five cardiac models were calculated by ECT and GS-Quant. 48 patients (13 female, 35 male) underwent a one day stress-rest protocol and gated SPECT. From these 96 gated SPECT images, left ventricular ejection fraction (LVEF), end-diastolic volume (EDV) and end-systolic volume (ESV) were estimated by ECT and GS-Quant. For 42 patients LVEF was also determined by echocardiography. Results: For the cardiac models the computed volumes showed high correlation with the model-volumes as well as high correlation between ECT and GS-Quant (r ≥0.99). Both programs underestimated the volume by approximately 20-30% independent of the ventricle-size. Calculating LVEF, EDV and ESV, GS-Quant and ECT correlated well to each other and to the LVEF estimated by echocardiography (r ≥0.86). LVEF values determined with ECT were about 10% higher than values determined with GS-Quant or echocardiography. The incorrect surfaces calculated by the automatic algorithm of GS-Quant for three examinations could not be corrected manually. 34 of the ECT studies were optimized by the operator. Conclusion: GS-Quant and ECT are two reliable programs in estimating LVEF. Both seem to underestimate the cardiac volume. In practical application GS-Quant was faster and easier to use. ECT allows the user to define the contour of the ventricle and thus is less susceptible to artifacts. (orig.) [de

  3. Left ventricular functional parameters by gated SPECT myocardial perfusion imaging in a Latin American country.

    Science.gov (United States)

    Kapitan, Miguel; Beltran, Alvaro; Beretta, Mario; Mut, Fernando

    2018-04-01

    There is paucity of data on left ventricular (LV) functional parameters using gated SPECT myocardial perfusion imaging (MPI) from the Latin American region. This study provides detailed information in low-risk patients both at rest and during exercise. We studied 90 patients (50 men) with a very low likelihood of coronary artery disease. Gated-SPECT MPI was performed with Tc-99m MIBI using a 2-day protocol, with 16 frames/R-R cycle. The LV ejection fraction and volumes were not different between the rest and post-stress images. LVEF was 68 ± 7% post-stress and 70 ± 7% at rest in women, and 62 ± 7% and 63 ± 7%, respectively, in men (P = .19, .26). LV volumes were larger in men than women (P stress. Transient ischemic dilatation was similar, with upper limits of 1.20 and 1.19 in women and men, respectively (P = NS). These data could prove helpful for the interpretation of gated SPECT MPI data in Latin America using identical protocol as used in this study.

  4. A unique case of bifid left testicular artery having its anomalous high origin from renal artery

    OpenAIRE

    Ashwini P Aithal; Naveen Kumar; Swamy S Ravindra; Jyothsna Patil

    2016-01-01

    The testicular arteries are known to originate from the ventrolateral aspect of the abdominal aorta and descend obliquely to the pelvic cavity and supply the testis. An anatomical description of an uncommon variation of the left testicular artery is presented in this case report, highlighting its clinical implications. During routine dissection of a male cadaver, we found that the left testicular artery was bifid and it was arising from the left renal artery. After its origin, it then coursed...

  5. The effect of prolonged of warm ischaemic injury on renal function in an experimental ex vivo normothermic perfusion system.

    Science.gov (United States)

    Hosgood, Sarah A; Shah, K; Patel, M; Nicholson, M L

    2015-06-30

    Donation after circulatory death (DCD) kidney transplants inevitably sustain a degree of warm ischaemic injury, which is manifested clinically as delayed graft function. The aim of this study was to define the effects of prolonged periods of warm ischaemic injury on renal function in a normothermic haemoperfused kidney model. Porcine kidneys were subjected to 15, 60, 90 (n = 6 per group) and 120 min (n = 4) of in situ warm ischaemia (WI) and then retrieved, flushed with cold preservation fluid and stored in ice for 2 h. Kidneys then underwent 3 h of normothermic reperfusion with a whole blood-based perfusate using an ex vivo circuit developed from clinical grade cardiopulmonary bypass technology. Creatinine clearance, urine output and fractional excretion of sodium deteriorated sequentially with increasing warm time. Renal function was severely compromised after 90 or 120 min of WI but haemodynamic, metabolic and histological parameters demonstrated the viability of kidneys subjected to prolonged warm ischaemia. Isolated kidney perfusion using a warm, oxygenated, red cell-based perfusate allows an accurate ex vivo assessment of the potential for recovery from warm ischaemic injury. Prolonged renal warm ischaemic injury caused a severe decrement in renal function but was not associated with tissue necrosis.

  6. Renal Perfusion and Function during Pneumoperitoneum: A Systematic Review and Meta-Analysis of Animal Studies

    Science.gov (United States)

    Warlé, Michiel C.; Hooijmans, Carlijn R.

    2016-01-01

    Both preclinical and clinical studies indicate that raised intra-abdominal pressure (IAP) associated with pneumoperitoneum during laparoscopic surgical procedures can cause renal damage, the severity of which may be influenced by variables such as pressure level and duration. Several of these variables have been investigated in animal studies, but synthesis of all preclinical data has not been performed. This systematic review summarizes all available pre-clinical evidence on this topic, including an assessment of its quality and risk of bias. We performed meta-analysis to assess which aspects of the pneumoperitoneum determine the severity of its adverse effects. A systematic search in two databases identified 55 studies on the effect of pneumoperitoneum on renal function which met our inclusion criteria. There was high heterogeneity between the studies regarding study design, species, sex, pressure and duration of pneumoperitoneum, and type of gas used. Measures to reduce bias were poorly reported, leading to an unclear risk of bias in the majority of studies. Details on randomisation, blinding and a sample size calculation were not reported in ≥80% of the studies. Meta-analysis showed an overall increase in serum creatinine during pneumoperitoneum, and a decrease in urine output and renal blood flow. Subgroup analysis indicated that for serum creatinine, this effect differed between species. Subgroup analysis of pressure level indicated that urine output decreased as IAP level increased. No differences between types of gas were observed. Data were insufficient to reliably assess whether sex or IAP duration modulate the effect of pneumoperitoneum. Four studies assessing long-term effects indicated that serum creatinine normalized ≥24 hours after desufflation of pneumoperitoneum at 15mmHg. We conclude that harmful effects on renal function and perfusion during pneumoperitoneum appear to be robust, but evidence on long-term effects is very limited. The

  7. Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Boogers, Mark J.; Chen, Ji; Garcia, Ernest V.; Bommel, Rutger J. van; Borleffs, C.J.W.; Schalij, Martin J.; Wall, Ernst E. van der; Bax, Jeroen J.; Dibbets-Schneider, Petra; Hiel, Bernies van der; Younis, Imad Al

    2011-01-01

    The aim of the current study was to evaluate the relationship between the site of latest mechanical activation as assessed with gated myocardial perfusion SPECT (GMPS), left ventricular (LV) lead position and response to cardiac resynchronization therapy (CRT). The patient population consisted of consecutive patients with advanced heart failure in whom CRT was currently indicated. Before implantation, 2-D echocardiography and GMPS were performed. The echocardiography was performed to assess LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV) and LV ejection fraction (LVEF). The site of latest mechanical activation was assessed by phase analysis of GMPS studies and related to LV lead position on fluoroscopy. Echocardiography was repeated after 6 months of CRT. CRT response was defined as a decrease of ≥15% in LVESV. Enrolled in the study were 90 patients (72% men, 67±10 years) with advanced heart failure. In 52 patients (58%), the LV lead was positioned at the site of latest mechanical activation (concordant), and in 38 patients (42%) the LV lead was positioned outside the site of latest mechanical activation (discordant). CRT response was significantly more often documented in patients with a concordant LV lead position than in patients with a discordant LV lead position (79% vs. 26%, p<0.01). After 6 months, patients with a concordant LV lead position showed significant improvement in LVEF, LVESV and LVEDV (p<0.05), whereas patients with a discordant LV lead position showed no significant improvement in these variables. Patients with a concordant LV lead position showed significant improvement in LV volumes and LV systolic function, whereas patients with a discordant LV lead position showed no significant improvements. (orig.)

  8. 13N-Ammonia pet-derived ventricular synchrony correlates with myocardial perfusion reserve better than left ventricular ejection fraction : A study in infarcted patients

    NARCIS (Netherlands)

    Juarez-Orozco, Luis Eduardo; Slart, Riemer; Tio, Rene A.; Inarra-Talboy, Fernando; Monroy, Andrea; Ayala-German, AnaGabriela; Dierckx, Rudi A.; Rosas, Erick Alexanderson

    2016-01-01

    Background: PET myocardial perfusion allows myocardial perfusion reserve (MPR) quantification as well as left ventricular ejection fraction (LVEF) and synchrony estimation through phase analysis. There is a relationship between MPR and LVEF and both have proven prognostic value in coronary artery

  9. Serial assessment of left ventricular function in various patient groups with Tl-201 gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wei Lingge; Kadoya, Masumi; Momose, Mitsuhiro; Kurozumi, Masahiro; Matsushita, Tsuyoshi; Yamada, Akira

    2007-01-01

    The present study was performed to assess stress-related left ventricular (LV) function variations in various patient groups and to determine if they were affected by sex or the type of stress experienced. We used thallium (Tl)-201 gated myocardial perfusion single-photon emission computed tomography (SPECT) for the analysis. A total of 270 patients were examined by electrocardiography-gated myocardial perfusion SPECT imaging to assess LV function. After injection of Tl-201 at a dose of 111 MBq at peak stress, SPECT scans were acquired at 10 min (after stress) and 3 h (rest) after injection on a three-headed camera. In the normal perfusion group, the mean LV ejection fraction (LVEF) was significantly higher, and both the end-diastolic volume index (EDVI) and end-systolic volume index (ESVI) were significantly lower in women than in men (P<0.05). Poststress stunning occurred in 29 of 98 patients (30.0%) in the ischemia group and in 42 of 90 patients (46.7%) in the fixed group. There was a significant difference in poststress stunning between bicycle ergometer stress and dipyridamole stress (P<0.05). In patients with normal perfusion, LVEF, EDVI, and ESVI determined by gated Tl-201 SPECT should be corrected for sex. In addition, the influence of the type of stress should be considered when assessing stress-related LV function variations. (author)

  10. Relationship between plasma BNP level and perfusion and function of the left ventricle in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Celinski, R.; Cholewinski, W.; Stefaniak, B.; Tarkowska, A.; Grzywa-Celinska, A.

    2004-01-01

    Elevation of the plasma BNP is known to occur in heart failure. However, some observations suggest that in patients with CAD an increase in BNP level may be caused also by the myocardial ischaemia. The study population comprised 79 patients with CAD, aged on average 59.6, and 18 healthy volunteers (CG). In patients with CAD g SPECT was performed using 99mT c tetrofosmin and myocardial perfusion and function were assessed quantitatively. Plasma BNP was measured using immunoradiometric method and was analyzed according to LVEF, EDV, ESV and two perfusion parameters: SCD and TPD. In all patients with CAD perfusion defects were found at rest. BNP concentration was significantly higher in CAD than in CG. In the group with dLVEF plasma BNP was distinctly higher than in that with nVEF but that difference was not significant. In pts with dLVEF significant correlation was found between BNP concentration on one hand and LVEF, EDV and ESV on the other. No significant relationships were observed between plasma BNP and both perfusion parameters. In patients with CAD the increase in plasma BNP level is related to the disorders of the left ventricular contractility, to the systolic function impairment first of all. Myocardial ischaemia without concomitant contractility disorders does not lead to elevation of BNP level. (author)

  11. Leiomyosarcoma of inferior vena cava involving bilateral renal veins: Surgical challenges and reconstruction with upfront saphenous vein interposition graft for left renal vein outflow

    Directory of Open Access Journals (Sweden)

    Rishi Nayyar

    2010-01-01

    Full Text Available Leiomyosarcoma of inferior vena cava (IVC involving bilateral renal veins presents a surgical challenge. Herein, we report the successful management of two such cases using restoration of left renal venous outflow by saphenous vein interposition graft as first step of surgery. Then radical resection of tumor and right kidney was done. IVC was lastly reconstructed using Gore-Tex graft. This report highlights the surgical challenges to ensure radical resection. Furthermore, the importance of restoring left renal outflow in presence of concomitant right nephrectomy is discussed. Both the patients were disease free at six months with no loss of left renal glomerular filtration rate.

  12. Renal Cell Carcinoma Perfusion before and after Radiofrequency Ablation Measured with Dynamic Contrast Enhanced MRI: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Tze Min Wah

    2018-01-01

    Full Text Available Aim: To investigate if the early treatment effects of radiofrequency ablation (RFA on renal cell carcinoma (RCC can be detected with dynamic contrast enhanced (DCE-MRI and to correlate RCC perfusion with RFA treatment time. Materials and methods: 20 patients undergoing RFA of their 21 RCCs were evaluated with DCE-MRI before and at one month after RFA treatment. Perfusion was estimated using the maximum slope technique at two independent sittings. Total RCC blood flow was correlated with total RFA treatment time, tumour location, size and histology. Results: DCE-MRI examinations were successfully evaluated for 21 RCCs (size from 1.3 to 4 cm. Perfusion of the RCCs decreased significantly (p < 0.0001 from a mean of 203 (±80 mL/min/100 mL before RFA to 8.1 (±3.1 mL/min/100 mL after RFA with low intra-observer variability (r ≥ 0.99, p < 0.0001. There was an excellent correlation (r = 0.95 between time to complete ablation and pre-treatment total RCC blood flow. Tumours with an exophytic location exhibit the lowest mean RFA treatment time. Conclusion: DCE-MRI can detect early treatment effects by measuring RCC perfusion before and after RFA. Perfusion significantly decreases in the zone of ablation, suggesting that it may be useful for the assessment of treatment efficacy. Pre-RFA RCC blood flow may be used to predict RFA treatment time.

  13. Left ventricular diastolic dysfunction in chronic renal failure patients on chronic hemodialysis in Dr. Cipto-Mangunkusumo Hospital : the association with left ventricular mass

    Directory of Open Access Journals (Sweden)

    Idrus Alwi

    2006-06-01

    Full Text Available Fourty three patients with chronic renal failure undergoing chronic hemodialysis in Division of Nephrology and Hypertension, Faculty of Medicine, University of Indonesia/Cipto-Mangunkusumo Hospital, Jakarta, since October 2003 until February 2004, were examined for echocardiography (2-D, M-mode, Doppler imaging.Diastolic dysfunction was found in 58.1 % of chronic renal failure patients on hemodialysis. There was no significant difference between left ventricular mass in the group with or without left ventricular diastolic dysfunction. (Med J Indones 2006; 15:105-8Keywords: Left ventricular mass, diastolic function, chronic renal failure, hemodyalisis

  14. Haemoadsorption reduces the inflammatory response and improves blood flow during ex vivo renal perfusion in an experimental model.

    Science.gov (United States)

    Hosgood, Sarah A; Moore, Tom; Kleverlaan, Theresa; Adams, Tom; Nicholson, Michael L

    2017-10-25

    Ex-vivo normothermic perfusion strategies are a promising new instrument in organ transplantation. The perfusion conditions are designed to be protective however the artificial environment can induce a local inflammatory response. The aim of this study was to determine the effect of incorporating a Cytosorb adsorber into an isolated kidney perfusion system. Porcine kidneys were subjected to 22 h of cold ischaemia then reperfused for 6 h on an ex vivo reperfusion circuit. Pairs of kidneys were randomised to either control (n = 5) or reperfusion with a Cytosorb adsorber (n = 5) integrated into the circuit. Tissue, blood and urine samples were taken for the measurement of inflammation and renal function. Baseline levels of cytokines (IL-6, TNFα, IL-8, IL-10, IL-1β, IL-1α) were similar between groups. Levels of IL-6 and IL-8 in the perfusate significantly increased during reperfusion in the control group but not in the Cytosorb group (P = 0.023, 0.049). Levels of the other cytokines were numerically lower in the Cytosorb group; however, this did not reach statistical significance. The mean renal blood flow (RBF) was significantly higher in the Cytosorb group (162 ± 53 vs. 120 ± 35 mL/min/100 g; P = 0.022). Perfusate levels of prostaglandin E2 were significantly lower in the Cytosorb group (642 ± 762 vs. 3258 ± 980 pg/mL; P = 0.0001). Levels of prostacyclin were significantly lower in the Cytosorb group at 1, 3 and 6 h of reperfusion (P = 0.008, 0.003, 0.0002). Levels of thromboxane were also significantly lower in the Cytosorb group throughout reperfusion (P = 0.005). Haemoadsorption had no effect on creatinine clearance (P = 0.109). Haemoadsorption can reduce the inflammatory response and improve renal blood flow during perfusion. Nonetheless, in this model haemoadsorption had no influence on renal function and this may relate to the broad-spectrum action of the Cytosorb adsorber that also removes potentially important anti

  15. A Case of Left Renal Vein Ligation in a Patient with Solitary Left Kidney Undergoing Liver Transplantation to Control Splenorenal Shunt and Improve Portal Venous Flow.

    Science.gov (United States)

    Martino, Rodrigo B; Júnior, Eserval Rocha; Manuel, Valdano; Rocha-Santos, Vinicius; D'Albuquerque, Luis Augusto C; Andraus, Wellington

    2017-10-11

    BACKGROUND Adequate portal venous flow is required for successful liver transplantation. Reduced venous flow and blood flow 'steal' by collateral vessels are a concern, and when there is a prominent splenorenal shunt present, ligation of the left renal vein has been recommended to improve portal venous blood flow. CASE REPORT A 51-year-old man who had undergone right nephrectomy in childhood required liver transplantation for liver cirrhosis and hepatocellular carcinoma due to hepatitis C virus (HCV) infection. The patient had no other comorbidity and no history of hepatorenal syndrome. At transplantation surgery, portal venous flow was poor and did not improve with ligation of shunt veins, but ligation of the left renal vein improved portal venous flow. On the first and fifth postoperative days, the patient was treated with basiliximab, a chimeric monoclonal antibody to the IL-2 receptor, and methylprednisolone. The calcineurin inhibitor, tacrolimus, was introduced on the fifth postoperative day. On the sixteenth postoperative day, renal color Doppler ultrasound showed normal left renal parenchyma; hepatic Doppler ultrasound showed good portal vein flow and preserved hepatic parenchyma in the liver transplant. CONCLUSIONS This case report has shown that in a patient with a single left kidney, left renal vein ligation is feasible and safe in a patient with no other risk factors for renal impairment following liver transplantation. Modification of postoperative immunosuppression to avoid calcineurin inhibitors in the very early postoperative phase may be important in promoting good recovery of renal function and to avoid the need for postoperative renal dialysis.

  16. Myocardial perfusion and left ventricular function early after successful PTCA in 1-vessel coronary artery diseases

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Kaiser, W.; Hanke, H.; Mueller-Schauenburg, W.; Karsch, K.R.; Seipel, L.

    1994-01-01

    Myocardial perfusion ( 201 Tl-ECT) and contractile function ( 99m Tc-ventriculography) were studied during exercise and rest 3 to 6 days after PTCA in 20 patients (11 with stable and 9 with unstable angina pectoris). All patients had single vessel disease and no previous myocardial infarction. During exercise after PTCA the ejection fraction increased for 3 to 5% and no regional wall motion abnormalities, ST-segment depression or perfusion defects occurred (with exception in one patient with very early restenosis). Therefore, perfusion and wall motion were completely normalized at test and during exercise within days after technically successful PTCA even in patients with previously unstable angina pectoris. Pathological stress test results after this time should thus be attributed to other causes e.g. early restenosis, multivessel disease, false positive tests) and are not due to the specific situation early after PTCA. (orig.) [de

  17. Myocardial visualization on a routine perfusion lung scintigram: Relationship to the amount of right-to-left shunt

    International Nuclear Information System (INIS)

    Seto, H.; Futatsuya, R.; Kamei, T.; Kakishita, M.; Hisada, K.

    1983-01-01

    Three cases of myocardial visualization on a routine perfusion lung scintigram with sup(99m)Tc-macroaggregaed albumin were reported in patients with congenital heart diseases; two cases of tetralogy of Fallot and one case of truncus arteriosus type IV. Large right-to-left shunts greater than 39% and marked hypertrophy of the ventricle suggesting the presence of increased coronary blood flow were noted in all cases. In the two patients with tetralogy of Fallot myocardial activity appeared to be located in the hypertrophic right venticles. (orig.)

  18. Myocardial visualization on a routine perfusion lung scintigram: Relationship to the amount of right-to-left shunt

    Energy Technology Data Exchange (ETDEWEB)

    Seto, H.; Futatsuya, R.; Kamei, T.; Kakishita, M.; Hisada, K.

    1983-11-14

    Three cases of myocardial visualization on a routine perfusion lung scintigram with sup(99m)Tc-macroaggregated albumin were reported in patients with congenital heart diseases; two cases of tetralogy of Fallot and one case of truncus arteriosus type IV. Large right-to-left shunts greater than 39% and marked hypertrophy of the ventricle suggesting the presence of increased coronary blood flow were noted in all cases. In the two patients with tetralogy of Fallot myocardial activity appeared to be located in the hypertrophic right venticles.

  19. Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)?

    International Nuclear Information System (INIS)

    Blomley, Martin J.K.; McBride, Alan; Mohammedtagi, Sima; Albrecht, Thomas; Harvey, Christopher J.; Jaeger, Rolf; Standfield, Nigel J.; Dawson, Peter

    1999-01-01

    Aim: To ensure optimal timing with pre-operative spiral CT for abdominal aortic aneurysms (AAA), an initial 'timing' single level CT is commonly performed with a small bolus of contrast. This can be exploited to obtain adjunct functional information on renal perfusion. We have investigated the potential of this to measure renal perfusion, to produce colour renal perfusion maps and to predict surgical outcome in infrarenal aortic aneurysm assessment. Methods: We studied 21 patients being assessed for repair of infrarenal AAA. Prior to the spiral CT, a single level through the renal hili and aorta was scanned after the intravenous injection of 25 ml of contrast given at 10 ml/s. Ten 1 s duration scans were performed from 8 to 30 s after injection. Optimal timing for CT angiography can then be determined. Time-density curves were then drawn for both kidneys and aorta using regions of interest (ROIs) or pixel-by-pixel analysis. Renal cortical perfusion was measured using both ROI analysis and pseudocolour perfusion images. Following previous work, perfusion was calculated as the peak upslope of the tissue time density curve divided by peak aortic enhancement. Results: Cortical mean perfusion averaged 2.48 ml/min per ml (range 0.8-3.7 ml/min per ml n=34) and the values obtained agreed with literature expectations. Follow up in the 10 patients proceeding to AAA repair suggest low mean perfusion values and predict a raised postoperative creatinine (P<0.05) Conclusions: Additional functional data and imaging can be obtained from the initial timing scan of a CT study, without requiring a dedicated study

  20. GATED SPECT TO EVALUATE LEFT VENTRICULAR MYOCARDIAL PERFUSION, FUNCTION AND DYSSYNCHRONY FOR RESYNCHRONIZATION THERAPY

    Directory of Open Access Journals (Sweden)

    E.N. Ostroumov

    2009-01-01

    Full Text Available The study included 15 consecutive patients with heart failure and substantial LV dyssynchrony undergoing CRT. Clinical and phase analysis of gated myocardial perfusion SPECT assessed at baseline, after 2–3 days and after 3–4 months of CRT. The results demonstrated inversely relationship between the response to CRT and the nonviable myocardium. Evaluation of myocardial viability is necessary to considered in the selection process for CRT.

  1. Differentiation of low- and high-grade clear cell renal cell carcinoma: Tumor size versus CT perfusion parameters.

    Science.gov (United States)

    Chen, Chao; Kang, Qinqin; Xu, Bing; Guo, Hairuo; Wei, Qiang; Wang, Tiegong; Ye, Hui; Wu, Xinhuai

    To compare the utility of tumor size and CT perfusion parameters for differentiation of low- and high-grade clear cell renal cell carcinoma (RCC). Tumor size, Equivalent blood volume (Equiv BV), permeability surface-area product (PS), blood flow (BF), and Fuhrman pathological grading of clear cell RCC were retrospectively analyzed. High-grade clear cell RCC had significantly higher tumor size and lower PS than low grade. Tumor size positively correlated with Fuhrman grade, but PS negatively did. Tumor size and PS were significantly independent indexes for differentiating high-grade from low-grade clear cell RCC. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. The findings of Tc-99m ECD brain perfusion SPECT in the patients with left anterior thalamic infarction

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Y. A.; Kim, S. H.; Sohn, H. S.; Jeong, S. G. [The Catholic University of Korea, Seoul (Korea, Republic of)

    2005-07-01

    The thalamus has multiple connections with areas of the cerebral cortex involved in arousal and cognition. Thalamic damage has been reported to be associated with variable neuropsychological dysfunctions and dementia. This study evaluates the changes of regional cerebral blood flow (rCBF) by using SPM analysis of brain perfusion SPECT and examining the neuropsychological abnormalities of 4 patients with anterior thalamic infarctions. Four patients with left anterior thalamic infarctions and eleven normal controls were evaluated. K-MMSE and the Seoul Neuropsychological Screening Battery were performed within 2 days after stroke. The normalized SPECT data of 4 patients were compared to those of 11 controls for the detection of areas with decreased rCBF by SPM analysis. All 4 patients showed anterograde amnesia in their verbal memory, which was not improved by recognition. Dysexecutive features were occasionally present, such as decreased word fluency and impaired Stroop test results. SPM analysis revealed decreased rCBF in the left supra marginal gyrus, the superior temporal gyrus, the middle and inferior frontal gyrus, the medial dorsal and anterior nucleus of the left thalamus. The changes of rCBF in patients with left anterior thalamic infarctions may be due to the remote suppression on metabolism by the interruption of the cortico-subcortical circuit, which connects the anterior thalamic nucleus and various cortical areas. The executive dysfunction and dysnomia may be caused by the left dorsolateral frontal dysfunction of the thalamo-cortical circuit. Anterograde amnesia with storage deficit may be caused by the disruption of mamillothalamic tract.

  3. The findings of Tc-99m ECD brain perfusion SPECT in the patients with left anterior thalamic infarction

    International Nuclear Information System (INIS)

    Jeong, Y. A.; Kim, S. H.; Sohn, H. S.; Jeong, S. G.

    2005-01-01

    The thalamus has multiple connections with areas of the cerebral cortex involved in arousal and cognition. Thalamic damage has been reported to be associated with variable neuropsychological dysfunctions and dementia. This study evaluates the changes of regional cerebral blood flow (rCBF) by using SPM analysis of brain perfusion SPECT and examining the neuropsychological abnormalities of 4 patients with anterior thalamic infarctions. Four patients with left anterior thalamic infarctions and eleven normal controls were evaluated. K-MMSE and the Seoul Neuropsychological Screening Battery were performed within 2 days after stroke. The normalized SPECT data of 4 patients were compared to those of 11 controls for the detection of areas with decreased rCBF by SPM analysis. All 4 patients showed anterograde amnesia in their verbal memory, which was not improved by recognition. Dysexecutive features were occasionally present, such as decreased word fluency and impaired Stroop test results. SPM analysis revealed decreased rCBF in the left supra marginal gyrus, the superior temporal gyrus, the middle and inferior frontal gyrus, the medial dorsal and anterior nucleus of the left thalamus. The changes of rCBF in patients with left anterior thalamic infarctions may be due to the remote suppression on metabolism by the interruption of the cortico-subcortical circuit, which connects the anterior thalamic nucleus and various cortical areas. The executive dysfunction and dysnomia may be caused by the left dorsolateral frontal dysfunction of the thalamo-cortical circuit. Anterograde amnesia with storage deficit may be caused by the disruption of mamillothalamic tract

  4. Posterior Nutcracker Syndrome Associated with Interrupted Left Inferior Vena Cava with Azygos Continuation and Retroaortic Right Renal Vein

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xiao Li; Zhou, Xiao Dong [Xijing Hospital, Fourth Military Medical University, Shaanxi (China); Qian, Gen Nian; Xiao, Hui; Zhao, Chun Lei [Fuzhou General Hospital, Fujian (China)

    2012-06-15

    Various anatomic anomalies have been considered the causes of nutcracker syndrome (NCS). Posterior NCS refers to the condition, in which vascular narrowing was secondary to the compression of the retroaortic left renal vein while it is crossing between the aorta and the vertebral column. Here, we report an unusual case of posterior NCS associated with a complicated malformation of the interrupted left inferior vena cava with azygos continuation and retroaortic right renal vein, diagnosed by both color Doppler ultrasonography and CT angiography.

  5. Posterior Nutcracker Syndrome Associated with Interrupted Left Inferior Vena Cava with Azygos Continuation and Retroaortic Right Renal Vein

    International Nuclear Information System (INIS)

    Luo, Xiao Li; Zhou, Xiao Dong; Qian, Gen Nian; Xiao, Hui; Zhao, Chun Lei

    2012-01-01

    Various anatomic anomalies have been considered the causes of nutcracker syndrome (NCS). Posterior NCS refers to the condition, in which vascular narrowing was secondary to the compression of the retroaortic left renal vein while it is crossing between the aorta and the vertebral column. Here, we report an unusual case of posterior NCS associated with a complicated malformation of the interrupted left inferior vena cava with azygos continuation and retroaortic right renal vein, diagnosed by both color Doppler ultrasonography and CT angiography.

  6. Quantification of left ventricular function by gated myocardial perfusion SPECT using multidimTM

    International Nuclear Information System (INIS)

    Huang Jin; Song Wenzhong; Chen Mingxi

    2004-01-01

    Objective: To evaluate the accuracy of left ventricular function by gated SPECT using the software Multidim TM . Methods: Rest gated SPECT was performed on 42 cases involved 26 normal subjects and 16 patients with myocardial infarct (MI). All cases underwent rest equilibrium radionuclide angiocardiography (ERNA) within 1 w. Results: (1)End diastolic volume (EDV), end systolic volume (ESV) and left ventricular ejection fraction(LVEF)were calculated using the software MultidimtMand ERNA. The correlation coefficient between the two Methods was 0.90,0.89,0.92 respectively(P TM , but the EDV and ESV value measured by this software maybe high with small heart. (authors)

  7. Left ventricular synchrony assessed by phase analysis of gated myocardial perfusion SPECT imaging in healthy subjects

    International Nuclear Information System (INIS)

    Wang Yuetao; Wang Jianfeng; Yang Minfu; Niu Rong

    2013-01-01

    Objective: To investigate the value of Cedars-Sinai quantitative gated SPECT (QGS) phase analysis for left ventricular synchrony assessment in healthy subjects. Methods: Seventy-four healthy subjects (41 males, 33 females,average age: (60±13) years) underwent both rest and exercise 99 Tc m -MIBI G-MPI. QGS software was used to analyze the reconstructed rest gated SPECT images automatically, and then the parameters of left ventricular synchrony including phase bandwidth (BW) and phase standard deviation (SD) were obtained. The influences of gender and age (age<60 years, n=36; age ≥ 60 years, n=38) on left ventricular systolic synchronicity were analyzed. The phase angle for original segmental contraction was measured to determine the onset of the ventricular contraction using 17-segment model. Forty healthy subjects were selected by simple random sampling method to evaluate the intra-observer and interobserver repeatability of QGS phase analysis software. Two-sample t test and linear correlation analysis were used to analyze the data. Results: The BW and SD of left ventricular in healthy subjects were (37.22 ±11.71)°, (11.84±5.39)° respectively. Comparisons between male and female for BW and SD yielded no statistical significance (BW: (36.00±9.70)°, (38.73±13.84)°; SD: (11.88±5.56)°, (11.79±5.26)°; t=0.96 and-0.07, both P>0.05); whereas the older subjects (age≥60 years) had larger BW than the others (age<60 years ; (39.95± 12.65)°, (34.33± 10.00)°; t=-2.11, P<0.05) and no statistical significance was shown for SD between the two age groups ((11.18±4.31)°, (12.54±6.33)°; t=1.08, P>0.05). Of the 74 subjects, the mechanical activation started from the ventricular base to apex in 54 subjects (73%), and from apex to base in only 20 subjects (27%). High repeatability of phase analysis was observed for both intra-observer and inter-observer (r=0.867-0.906, all P<0.001). Conclusions: Good left ventricular segmental synchrony is shown in healthy

  8. Nutcracker or left renal vein compression phenomenon: multidetector computed tomography findings and clinical significance

    International Nuclear Information System (INIS)

    Cuellar i Calabria, Hug; Quiroga Gomez, Sergi; Sebastia Cerqueda, Carmen; Boye de la Presa, Rosa; Miranda, Americo; Alvarez-Castells, Agusti

    2005-01-01

    The use of multidetector computed tomography (MDCT) in routine abdominal explorations has increased the detection of the nutcracker phenomenon, defined as left renal vein (LRV) compression by adjacent anatomic structures. The embryology and anatomy of the nutcracker phenomenon are relevant as a background for the nutcracker syndrome, a rare cause of hematuria as well as other symptoms. MDCT examples of collateral renal vein circulation (gonadal, ureteric, azygous, lumbar, capsular) and aortomesenteric (anterior) and retroaortic (posterior) nutcracker phenomena in patients with no urologic complaint are shown as well as studies performed on patients with gross hematuria of uncertain origin. Incidental observation of collateral veins draining the LRV in abdominal MDCT explorations of asymptomatic patients may be a sign of a compensating nutcracker phenomenon. Imbalance between LRV compression and development of collateral circulation may lead to symptomatic nutcracker syndrome. (orig.)

  9. Nutcracker or left renal vein compression phenomenon: multidetector computed tomography findings and clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Cuellar i Calabria, Hug; Quiroga Gomez, Sergi; Sebastia Cerqueda, Carmen; Boye de la Presa, Rosa; Miranda, Americo; Alvarez-Castells, Agusti [Hospitals Universitaris Vall D' Hebron, Institut de Diagnostic Per La Imatge, Servei De Radiodiagnostic, Barcelona (Spain)

    2005-08-01

    The use of multidetector computed tomography (MDCT) in routine abdominal explorations has increased the detection of the nutcracker phenomenon, defined as left renal vein (LRV) compression by adjacent anatomic structures. The embryology and anatomy of the nutcracker phenomenon are relevant as a background for the nutcracker syndrome, a rare cause of hematuria as well as other symptoms. MDCT examples of collateral renal vein circulation (gonadal, ureteric, azygous, lumbar, capsular) and aortomesenteric (anterior) and retroaortic (posterior) nutcracker phenomena in patients with no urologic complaint are shown as well as studies performed on patients with gross hematuria of uncertain origin. Incidental observation of collateral veins draining the LRV in abdominal MDCT explorations of asymptomatic patients may be a sign of a compensating nutcracker phenomenon. Imbalance between LRV compression and development of collateral circulation may lead to symptomatic nutcracker syndrome. (orig.)

  10. Left ventricular ejection fraction determined by gated Tl-201 perfusion SPECT and quantitative software

    International Nuclear Information System (INIS)

    Hyun, In Young; Kim, Sung Eun; Seo, Jeong Kee; Hong, Eui Soo; Kwan, Jun; Park, Keum Soo; Lee, Woo Hyung

    2000-01-01

    We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT (40%±14%) and GBP scan (43%±14%). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=3D0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2%. Ninety-five percent limits of agreement were ±9.8%. EF between g-Tl-SPECT and GBP scan were in poor agreement. The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.=20

  11. Influence of nifedipine on left ventricular perfusion and function in patients with unstable angina: Evaluation with radionuclide techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wall, E.E. van der; Kerkkamp, H.J.; Simoons, M.L.; Rijk, P.P. van; Reiber, J.H.C.; Bom, N.; Lubsen, J.C.; Lie, K.I.

    1986-04-01

    In 1981, a large, double-blind, randomized trial was started in The Netherlands to evaluate the therapeutic effects of nifedipine and/or metoprolol in patients with unstable angina. This study has been called the Holland Interuniversity Nifedipine/metoprolol Trial (HINT) and required several hundred patients to establish potential therapeutic effects. From December 1982 to January 1984 the effects of nifedipine on left ventricular (LV) performance in a subgroup of 52 HINT patients were studied using radionuclide techniques. All patients (23 on nifedipine, 29 controls) underwent thallium-201 scintigraphy or radionuclide angiography just before and 48 h after the start of experimental medication. The radionuclide angiographic studies were also performed at 1 and 4 h after treatment. Nifedipine did not influence the incidence of disapperance of perfusion defects on the 48-h thallium images. No significant differences in overall LV ejections fraction (EF) were seen at any time between nifedipine-treated patients and controls. However, paired observations in 37 patients showed improvement of LVEF after 48 h in 8 patients on nifedipine and in only 1 control patient. Scintigraphic measurements on admission were not related to clinical outcome after 48 h. Concomitant administration of metoprolol did not influence LVEF in either group. It is concluded that nifedipine improves LVEF after 48 h in a subset of patients with unstable angina without affecting myocardial perfusion. This finding indicates that nifedipine has a predominant effect on afterload reduction in patients with unstable angina. Also, early scintigraphic measurements had no significant predictive value for subsequent cardiac events.

  12. CT of anomalies of the inferior vena cava and left renal vein

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Oyama, Kazuyuki; Ohtomo, Kuni; Yashiro, Naobumi; Itai, Yuji; Iio, Masahiro; Masuyama, Shigeyoshi.

    1988-01-01

    Incidence of anomalies of the inferior vena cava (IVC) and left renal vein (LRV) was examined with post-contrast abdominal CT studies in the last five years and seven months retrospectively. Of the total 1100 cases, right retrocaval ureter was noted in two cases (0.2 %), left IVC was two (0.2 %) and bilateral IVC was twelve (1.1 %) about anomalies of the IVC. As to anomalies of the LRV, retroaortic LRV was four (0.4 %) and circumaortic LRV was six (0.5 %). These results did not always agree with those of previous reports on dissection cases. Particularly, incidence of anomalies of the LRV on CT was much lower than that on dissection. We speculated that racial difference was one of its causes. Clinical usefulness of CT for evaluation of anomalies of the IVC and LRV was stressed. (author)

  13. Utility of 99mTc-MAG3 perfusion indices in the evaluation of renal transplant function during early post-transplantation period

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chung, Soo Kyo

    2000-01-01

    We have examined the utility of 99m Tc-MAG3 perfusion indices for assessing renal graft function in early post-transplantation period. Our study included 80 renal transplant recipients (48 men and 32 women, mean age:40.3 years). Diagnosis was based on biopsy, laboratory data and clinical course. Renal scintigraphy (RS) was obtained using 100 MBq of 99m Tc-MAG3 from 11 days to 23 days of kidney transplantation. We measured 5 indices in whole-kidney (WK) and cortical (C) renograms; Hilson's perfusion index (PI), transplant perfusion index (TP) and transplant function index (TF) as perfusion parameter, and the time to peak activity (Tmax) and the ratio of renal counts at 20 min to that at 3 min (K20/3) as functional parameter. The diagnoses at the day of RS were normal graft (NG) in 44, acute rejection (AR) in 14, acute tubular necrosis (ATN) in 10, and Cyclosporine A nephrotoxicity (CsA) in 12. TP and TF were significantly decreased in AR, ATN and CsA, compared to those in NG. K20/3 of AR and ATN were significantly greater than that of NG. WK-Tmax of AR was significantly longer than than that of NG. K20.3 of AR and C-K20/3 of ATN were significantly prolonged relative to those of CsA. There were no statistically significant perfusion indices among complication groups. TP and TF reflecting microperfusion and initial tubular extraction are reliable in assessing graft function. However, it is required to correlate perfusion indices with functional indices and clinical course in differentiating from one another among complication groups

  14. Utility of {sup 99m}Tc-MAG3 perfusion indices in the evaluation of renal transplant function during early post-transplantation period

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoon; Chung, Soo Kyo [College of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2000-12-01

    We have examined the utility of {sup 99m}Tc-MAG3 perfusion indices for assessing renal graft function in early post-transplantation period. Our study included 80 renal transplant recipients (48 men and 32 women, mean age:40.3 years). Diagnosis was based on biopsy, laboratory data and clinical course. Renal scintigraphy (RS) was obtained using 100 MBq of {sup 99m}Tc-MAG3 from 11 days to 23 days of kidney transplantation. We measured 5 indices in whole-kidney (WK) and cortical (C) renograms; Hilson's perfusion index (PI), transplant perfusion index (TP) and transplant function index (TF) as perfusion parameter, and the time to peak activity (Tmax) and the ratio of renal counts at 20 min to that at 3 min (K20/3) as functional parameter. The diagnoses at the day of RS were normal graft (NG) in 44, acute rejection (AR) in 14, acute tubular necrosis (ATN) in 10, and Cyclosporine A nephrotoxicity (CsA) in 12. TP and TF were significantly decreased in AR, ATN and CsA, compared to those in NG. K20/3 of AR and ATN were significantly greater than that of NG. WK-Tmax of AR was significantly longer than than that of NG. K20.3 of AR and C-K20/3 of ATN were significantly prolonged relative to those of CsA. There were no statistically significant perfusion indices among complication groups. TP and TF reflecting microperfusion and initial tubular extraction are reliable in assessing graft function. However, it is required to correlate perfusion indices with functional indices and clinical course in differentiating from one another among complication groups.

  15. A randomized, controlled, double-blind crossover study on the effects of 2-L infusions of 0.9% saline and plasma-lyte® 148 on renal blood flow velocity and renal cortical tissue perfusion in healthy volunteers.

    Science.gov (United States)

    Chowdhury, Abeed H; Cox, Eleanor F; Francis, Susan T; Lobo, Dileep N

    2012-07-01

    We compared the effects of intravenous infusions of 0.9% saline ([Cl] 154 mmol/L) and Plasma-Lyte 148 ([Cl] 98 mmol/L, Baxter Healthcare) on renal blood flow velocity and perfusion in humans using magnetic resonance imaging (MRI). Animal experiments suggest that hyperchloremia resulting from 0.9% saline infusion may affect renal hemodynamics adversely, a phenomenon not studied in humans. Twelve healthy adult male subjects received 2-L intravenous infusions over 1 hour of 0.9% saline or Plasma-Lyte 148 in a randomized, double-blind manner. Crossover studies were performed 7 to 10 days apart. MRI scanning proceeded for 90 minutes after commencement of infusion to measure renal artery blood flow velocity and renal cortical perfusion. Blood was sampled and weight recorded hourly for 4 hours. Sustained hyperchloremia was seen with saline but not with Plasma-Lyte 148 (P Blood volume changes were identical (P = 0.867), but there was greater expansion of the extravascular fluid volume after saline (P = 0.029). There was a significant reduction in mean renal artery flow velocity (P = 0.045) and renal cortical tissue perfusion (P = 0.008) from baseline after saline, but not after Plasma-Lyte 148. There was no difference in concentrations of urinary neutrophil gelatinase-associated lipocalin after the 2 infusions (P = 0.917). This is the first human study to demonstrate that intravenous infusion of 0.9% saline results in reductions in renal blood flow velocity and renal cortical tissue perfusion. This has implications for intravenous fluid therapy in perioperative and critically ill patients. NCT01087853.

  16. Unusual case of left iliac vein compression secondary to May-Thurner syndrome and crossed fused renal ectopia

    International Nuclear Information System (INIS)

    Elsharawy, Mohamed A.; Moghazy, Kahled M.; Alsaif, Hind S.; Al-Asiri, Mosad M.

    2008-01-01

    External compression of the left iliac vein against the fifth lumbar vertebra by the right iliac artery (May and Thurner Syndrome) is a well known anatomic variant. We identified a rare case of May-Thurner syndrome associated with crossed fused renal ectopia on the left side. The patient presented with complete thrombosis of the left common iliac vein down to the popliteal vein. He was treated with catheter directed thrombolysis followed by anticoagulant therapy. (author)

  17. Impact of patient-specific factors, irradiated left ventricular volume, and treatment set-up errors on the development of myocardial perfusion defects after radiation therapy for left-sided breast cancer

    International Nuclear Information System (INIS)

    Evans, Elizabeth S.; Prosnitz, Robert G.; Yu Xiaoli; Zhou Sumin; Hollis, Donna R.; Wong, Terence Z.; Light, Kim L.; Hardenbergh, Patricia H.; Blazing, Michael A.; Marks, Lawrence B.

    2006-01-01

    Purpose: The aim of this study was to assess the impact of patient-specific factors, left ventricle (LV) volume, and treatment set-up errors on the rate of perfusion defects 6 to 60 months post-radiation therapy (RT) in patients receiving tangential RT for left-sided breast cancer. Methods and Materials: Between 1998 and 2005, a total of 153 patients were enrolled onto an institutional review board-approved prospective study and had pre- and serial post-RT (6-60 months) cardiac perfusion scans to assess for perfusion defects. Of the patients, 108 had normal pre-RT perfusion scans and available follow-up data. The impact of patient-specific factors on the rate of perfusion defects was assessed at various time points using univariate and multivariate analysis. The impact of set-up errors on the rate of perfusion defects was also analyzed using a one-tailed Fisher's Exact test. Results: Consistent with our prior results, the volume of LV in the RT field was the most significant predictor of perfusion defects on both univariate (p = 0.0005 to 0.0058) and multivariate analysis (p = 0.0026 to 0.0029). Body mass index (BMI) was the only significant patient-specific factor on both univariate (p = 0.0005 to 0.022) and multivariate analysis (p = 0.0091 to 0.05). In patients with very small volumes of LV in the planned RT fields, the rate of perfusion defects was significantly higher when the fields set-up 'too deep' (83% vs. 30%, p = 0.059). The frequency of deep set-up errors was significantly higher among patients with BMI ≥25 kg/m 2 compared with patients of normal weight (47% vs. 28%, p = 0.068). Conclusions: BMI ≥25 kg/m 2 may be a significant risk factor for cardiac toxicity after RT for left-sided breast cancer, possibly because of more frequent deep set-up errors resulting in the inclusion of additional heart in the RT fields. Further study is necessary to better understand the impact of patient-specific factors and set-up errors on the development of RT

  18. Absence of Middle Hepatic Vein Combined with Retro-Aortic Left Renal Vein: a Very Rare Case Report

    Directory of Open Access Journals (Sweden)

    Sezer Akçer

    2012-06-01

    Full Text Available The hepatic and renal veins drain into the inferior vena cava. The upper group of hepatic veins consists of three veins which extend to the posterior face of the liver to join the inferior cava. The left renal vein passes anterior to the aorta just below the origin of the superior mesenteric artery. We detected a variation in the hepatic and renal veins in a multislice CT angiogram of a nine-year-old male patient in the Radiology Department of Afyon Kocatepe University Medical School. The upper group hepatic veins normally drains into the inferior vena cava as three separate trunks, namely the right, left and middle. In our case, we found that only the right and left hepatic veins existed and the middle hepatic vein was absent. Furthermore, the left renal vein, which normally passes anterior to the abdominal aorta, was retro-aortic. Left renal vein variations are of great importance in planning retroperitoneal surgery and vascular interventions. Knowledge of a patient’s hepatic vein and renovascular anatomy and determining their variations and anomalies are of critical importance to abdominal operations, transplantations and preoperative evaluation of endovascular interventions.

  19. Global and regional left ventricular function and tomographic radionuclide perfusion: the Western Washington Intracoronary Streptokinase In Myocardial Infarction Trial

    International Nuclear Information System (INIS)

    Ritchie, J.L.; Davis, K.B.; Williams, D.L.; Caldwell, J.; Kennedy, J.W.

    1984-01-01

    The Western Washington Intracoronary Streptokinase In Myocardial Infarction Trial enrolled 250 patients with acute myocardial infarction. After the coronary angiographic diagnosis of thrombosis, patients were randomly assigned to receive either conventional therapy with heparin or intracoronary streptokinase followed by heparin. Of the 232 patients who survived at least 60 days, 207 (89%) underwent radionuclide ventriculographic determination of global and regional ejection fraction at a single institution at 62 +/- 35 days after infarction. In the first 100 patients, infarct size was also determined by quantitative single-photon emission tomographic imaging with thallium-201 ( 201 Tl) and expressed as a percentage of the left ventricle with a perfusion defect. Overall, global ejection fraction did not differ between patients treated with streptokinase (45.9 +/- 13.9%; n . 115) and control patients (46.1 +/- 14.4%; n . 92, p . NS). Similarly, the regional posterolateral, inferior, and anteroseptal ejection fraction did not differ between the two groups. Infarct size as measured by 201 Tl tomography was 19.4 +/- 12.8% (n . 52) of the left ventricle for the streptokinase group and 19.6 +/- 11.8% (n . 48; p . NS) for the control group. When patients were compared within groups by electrocardiographic location of infarction, time to treatment, or the presence or absence of vessel opening, there were no significant differences between streptokinase and control patients. Statistical inclusion of the 18 patients who died early and were unavailable for study also failed to modify the results, except for a possible reduction in inferior infarct size as measured by 201 Tl tomography

  20. Left ventricular diastolic dyssynchrony assessed with phase analysis of gated myocardial perfusion SPECT: a comparison with tissue Doppler imaging

    International Nuclear Information System (INIS)

    Boogers, Mark J.; Veltman, Caroline E.; Chen, Ji; Garcia, Ernest V.; Bommel, Rutger J. van; Mooyaart, Eline A.Q.; Wall, Ernst E. van der; Schalij, Martin J.; Bax, Jeroen J.; Delgado, Victoria; Younis, Imad Al; Hiel, Bernies van der; Dibbets-Schneider, Petra

    2011-01-01

    The aim of the current study was to evaluate the feasibility of phase analysis on gated myocardial perfusion SPECT (GMPS) for the assessment of left ventricular (LV) diastolic dyssynchrony in a head-to-head comparison with tissue Doppler imaging (TDI). The population consisted of patients with end-stage heart failure of New York Heart Association functional class III or IV with a reduced LV ejection fraction of ≤35%. LV diastolic dyssynchrony was calculated using TDI as the maximal time delay between early peak diastolic velocities of two opposing left ventricle walls (diastolic mechanical delay). Significant LV diastolic dyssynchrony was defined as a diastolic mechanical delay of >55 ms on TDI. Furthermore, phase analysis on GMPS was performed to evaluate LV diastolic dyssynchrony; diastolic phase standard deviation (SD) and histogram bandwidth (HBW) were used as markers of LV diastolic dyssynchrony. A total of 150 patients (114 men, mean age 66.0 ± 10.4 years) with end-stage heart failure were enrolled. Both diastolic phase SD (r = 0.81, p 55 ms) showed significantly larger diastolic phase SD (68.1 ± 13.4 vs. 40.7 ± 14.0 , p < 0.01) and diastolic HBW (230.6 ± 54.3 vs. 129.0 ± 55.6 , p < 0.01) as compared to patients without LV diastolic dyssynchrony on TDI (≤55 ms). Finally, phase analysis on GMPS showed a good intra- and interobserver reproducibility for the determination of diastolic phase SD (ICC 0.97 and 0.88) and diastolic HBW (ICC 0.98 and 0.93). Phase analysis on GMPS showed good correlations with TDI for the assessment of LV diastolic dyssynchrony. (orig.)

  1. Prediction of cardiac events in patients with transient left ventricle dilation on stress myocardial perfusion SPECT images

    International Nuclear Information System (INIS)

    Fukuda, Hiroshi; Moroi, Masao

    2005-01-01

    The purpose of this study was to investigate cardiac events in patients with transient left ventricle (LV) dilation on stress myocardial perfusion single-photon emission computed tomography images (MPI). Consecutive patients (n=53, 31 males, mean age 71 years) with transient LV dilation on thallium-201 stress MPI (treadmill: 21, pharmacologic: 32) were followed for 17 months. Follow-up time was censored at the occurrence of cardiac death, congestive heart failure, acute coronary syndrome, or revascularization. Images were scored and then the summed stress score (SSS), summed rest score, and summed difference score were calculated. Cardiac death occurred in 3 patients, hospitalization occurred in 8 patients, and revascularization occurred in 20 patients. The combined cardiac event rate was 59% (76% for exercise stress vs 47% for pharmacologic stress, p=0.034.). Cox regression analysis demonstrated that a combination of higher SSS and slow washout rate was the best predictor of cardiac events (hazard ratio=3.3, p=0.029). A high cardiac event rate is associated with transient LV dilation on thallium-201 stress MPI. The event rate is particularly high for exercise stress MPI. Furthermore, a combination of the SSS and thallium-201 slow washout is the best predictor of cardiac events in patients with transient LV dilation. (author)

  2. Evaluation of noncoronary sources of left ventricular perfusion to intercoronary collateral-dependent myocardium due to chronic major vessel occlusion: absent contribution of luminal and extracardiac channels

    International Nuclear Information System (INIS)

    Crystal, G.J.; Downey, H.F.; Bashour, F.A.

    1981-01-01

    Liminal contribution to perfusion of collateral-dependent left ventricular (LV) myocardium was evaluated in six dogs. A portion of LV free wall was rendered collateral-dependent by gradual occlusion of left circumflex artery with Ameroid constrictor. Eight to 10 weeks after implantation of constrictor, measurements of LV myocardial flow were made by left atrial injections of 9-10 micro radioactive microspheres. To measure total collateral flow, microspheres were injected under control conditions, and to measure luminal contribution to collateral flow, microspheres were injected after ligation of right coronary artery during extracorporeal perfusion of left common coronary artery (LCCA) with microsphere-free arterial blood, and during stoppage of flow through LCCA. Under control conditions, myocardial blood flow in collateral-dependent region, 1.01 +/- 0.31 ml/min/gm, was not significantly different from that in normal region, 1.06 +/- 0.32 ml/min/gm. Flow from luminal collateral vessels was negligible (less than 0.005 ml/min/gm) in both collateral-dependent and normal myocardium, and was not affected by stoppage of flow through LCCA. These results indicate that luminal collateral vessels, as well as collateral vessels originating from other noncoronary sources, do not contribute significantly to perfusion of normal or collateral-dependent LV myocardium

  3. Utility of Deep Inspiration Breath Hold for Left-Sided Breast Radiation Therapy in Preventing Early Cardiac Perfusion Defects: A Prospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Zagar, Timothy M., E-mail: zagar@med.unc.edu [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Kaidar-Person, Orit [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Tang, Xiaoli [Memorial Sloan Kettering Cancer Center, West Harrison, New York (United States); Jones, Ellen E.; Matney, Jason; Das, Shiva K.; Green, Rebecca L. [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Sheikh, Arif [Department of Radiology, Columbia University, New York, New York (United States); Khandani, Amir H.; McCartney, William H.; Oldan, Jorge Daniel; Wong, Terence Z. [Department of Radiology, University of North Carolina, Chapel Hill, North Carolina (United States); Marks, Lawrence B. [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States)

    2017-04-01

    Purpose: To evaluate early cardiac single photon computed tomography (SPECT) findings after left breast/chest wall postoperative radiation therapy (RT) in the setting of deep inspiration breath hold (DIBH). Methods and Materials: We performed a prospective single-institution single-arm study of patients who were planned for tangential RT with DIBH to the left breast/chest wall (± internal mammary nodes). The DIBH was done by use of a controlled surface monitoring technique (AlignRT, Vision RT Ltd, London, UK). The RT was given with tangential fields and a heart block. Radiation-induced cardiac perfusion and wall motion changes were assessed by pre-RT and 6-month post-RT SPECT scans. A cumulative SPECT summed-rest score was used to quantify perfusion in predefined left ventricle segments. The incidence of wall motion abnormalities was assessed in each of these same segments. Results: A total of 20 patients with normal pre-RT scans were studied; their median age was 56 years (range, 39-72 years). Seven (35%) patients also received irradiation to the left internal mammary chain, and 5 (25%) received an additional RT field to supraclavicular nodes. The median heart dose was 94 cGy (range, 56-200 cGy), and the median V25{sub Gy} was zero (range, 0-0.1). None of the patients had post-RT perfusion or wall motion abnormalities. Conclusions: Our results suggest that DIBH and conformal cardiac blocking for patients receiving tangential RT for left-sided breast cancer is an effective means to avoid early RT-associated cardiac perfusion defects.

  4. Quantitative Renal Cortical Perfusion in Human Subjects with Magnetic Resonance Imaging Using Iron-Oxide Nanoparticles: Influence of T1 Shortening

    Energy Technology Data Exchange (ETDEWEB)

    Morell, A.; Ahlstrom, H.; Schoenberg, S.O.; Abildgaard, A.; Bock, M.; Bjoernerud, A. (Dept. of Diagnostic Radiology, Uppsala Univ. Hospital, Uppsala (Sweden))

    2008-10-15

    Background: Using conventional contrast agents, the technique of quantitative perfusion by observing the transport of a bolus with magnetic resonance imaging (MRI) is limited to the brain due to extravascular leakage. Purpose: To perform quantitative perfusion measurements in humans with an intravascular contrast agent, and to estimate the influence of the T1 relaxivity of the contrast agent on the first-pass response. Material and Methods: Renal cortical perfusion was measured quantitatively in six patients with unilateral renal artery stenosis using a rapid gradient double-echo sequence in combination with an intravenous bolus injection of NC100150 Injection, an intravascular contrast agent based on iron-oxide nanoparticles. The influence of T1 relaxivity was measured by comparing perfusion results based on single- and double-echo data. Results: The mean values of cortical blood flow, cortical blood volume, and mean transit time in the normal kidneys were measured to 339+-60 ml/min/100 g, 41+-8 ml/100 g, and 7.3+-1.0 s, respectively, based on double-echo data. The corresponding results based on single-echo data, which are not compensated for the T1 relaxivity, were 254+-47 ml/min/100 g, 27+-3 ml/100 g, and 6+-1.2 s, respectively. Conclusion: The use of a double-echo sequence enabled elimination of confounding T1 effects and consequent systematic underestimation of the perfusion.

  5. Recombinant erythropoietin acutely decreases renal perfusion and decouples the renin-angiotensin-aldosterone system

    DEFF Research Database (Denmark)

    Aachmann-Andersen, Niels J.; Christensen, Soren J.; Lisbjerg, Kristian

    2018-01-01

    The effect of recombinant erythropoietin (rhEPO) on renal and systemic hemodynamics was evaluated in a randomized double-blinded, cross-over study. Sixteen healthy subjects were tested with placebo, or low-dose rhEPO for 2 weeks, or high-dose rhEPO for 3 days. Subjects refrained from excessive salt...... that seems to decouple the activity of the renin-angiotensin-aldosterone system from changes in renal hemodynamics. This may serve as a negative feed-back mechanism on endogenous synthesis of EPO when circulating levels of EPO are high. These results demonstrates for the first time in humans a direct effect...... of rhEPO on renal hemodynamics and a decoupling of the renin-angiotensin-aldosterone system....

  6. Visualization of hypertrophied papillary muscle mimicking left ventricular mass on gated blood pool and T1-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Bunko, H.; Nakajima, K.; Tonami, N.; Asanoi, H.; Hisada, K.

    1981-01-01

    A sixty-year old man with acute myocardial infarction was incidentally found to have a hypertrophied anterolateral papillary muscle (ALPPM) of the left ventricle on gated blood pool (GBP) and T1-201 myocardial perfusion images. Hypertrophy of the ALPPM was visualized as a movable defect in the lateral basal area on GBP imaging throughout the cardiac cycle and on the TI-201 study as a radionuclide accumulating structure, consistent with the defect in the GBP. A combination of these findings may suggest the presence of a hypertrophied papillary muscle of the left ventricle

  7. Long-term safety of left renal vein division and ligation to expedite complex abdominal aortic surgery.

    Science.gov (United States)

    Samson, Russell H; Lepore, Michael R; Showalter, David P; Nair, Deepak G; Lanoue, Julien B

    2009-09-01

    Left renal vein division and ligation (LRVDAL) is performed to facilitate complex abdominal aortic surgery. Surgeons restore continuity of the vein due to concern that ligation could cause renal compromise or hematuria. However, we report the short and long-term safety of left renal vein division and ligation. Between 1992 and 2007, we divided the left renal vein in 56 patients (40 males, 16 females) ages 57 to 84 (average 74-years-old) who were treated for aortic occlusive disease (9) or abdominal aortic aneurysm (47). Patients requiring concomitant renal artery reconstruction were excluded from this review. Suprarenal cross-clamp was used in 51 patients with temporary vessel-loop control of the renal arteries. Creatinine (Cr) and glomerular filtration rates (eGFR) were measured pre-, post-, and long-term after surgery. Outpatient records of all patients that had survived more than 12 months were also reviewed in order to evaluate the late effects on renal function or symptoms possibly related to LRVDAL. Median procedure duration was 157 (61-375) minutes. Median cross-clamp time was 16 (10-45) minutes. Median intensive care unit (ICU) and hospital length of stays were 2 (1-11) days and 7 (4-58) days, respectively. There were no deaths. There were no complications directly related to renal vein ligation. Hematuria, seen in 2 patients, was a result of traumatic insertion of a Foley catheter. Median pre-op and discharge Cr levels were 1.1 mg/dL (0.7-2.4 mg/dL) and 1.1 mg/dL (0.6-2.1 mg/dL), respectively (P 2.0 mg/dL remained unchanged post-op. Only 2 patients with a Cr of 2.0 mg/dL and both returned to normal by day 3 post-op. Thirty-six patients have been followed for more than a year (median 34.5 months, maximum 144 months) and Cr has remained stable in all but 2 patients. These 2 patients, both with a pre-op Cr of 1.5 mg/dL, subsequently developed Cr levels of 2.1 mg/dL and 2.4 mg/dL but maintained baseline Cr levels for 25 and 34 months, respectively, before

  8. Application of the four formula of software ECToolbox for the assessment of left ventricular ejection fraction in myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Xia Wei; Ni Jing; Zhuang Juhua; Hu Cuihua

    2014-01-01

    Objective: To compare the four formula of software programs ECToolbox for the assessment of left ventricular ejection fraction (LVEF) with equilibrium radionuclide ventriculography. And to calculate the normal cutoff values for the four formula. Methods: A total of 103 patients (59 men, 44 women) were recruited into the study. Thirty-eight patients had known CAD and sixty-five were referred with suspicion of CAD. All the patients underwent equilibrium radionuclide ventriculograph (ERNV) and ECG-gated myocardial perfusion SPECT (GMPS) as the standard protocol. LVEF values were separately calculated with formula R_0, R_1, R_2, R_3 of ECToolbox software, and the results were compared with LVEF values from ERNV. The normal cutoff values for the four formula were calculated by using normal cutoff values greater than or equal to 50% in ERNV as the classifying variable. Results: The mean LVEF on ERNV was 54.6% ± 17.5%. The mean LVEF values for formula R_0, R_1, R_2, R_3 were 64.1% ± 15.7%, 56.3% ± 15.1%, 69.9% ± 17.9%, 56.3% ± 13.6%, respectively. On correlation analysis, a very strong positive correlation was observed between LVEF values derived by ERNV and those derived by the four formula (all of r values were greater than 0.85, P O.05). Normal cutoff values for LVEF on R_0, R_1, R_2, R_3 were 56.5%, 51.5%, 64.5%, 52.5%, respectively, using a 50% or more cutoff value on ERNV. Conclusion: A strong correlation was observed among the four formula of ECToolbox software programs when compared with ERNV. However, there are subtle differences in the objective values of LVEF generated by individual calculation methods, which must be taken into account for clinical studies. (authors)

  9. Performance of Thallium-201 Electrocardiography-gated Myocardial Perfusion Single Photon Emission Computed Tomography to Assess Left Ventricular Function

    Directory of Open Access Journals (Sweden)

    Guang-Uei Hung

    2005-05-01

    Full Text Available This study evaluated the performance of gated single photon emission computed tomography (SPECT with thallium-201 (201Tl in assessing left ventricular ejection fraction (LVEF, end-diastolic volume (EDV, and end-systolic volume (ESV in Taiwanese by determining repeatability and correlation with two-dimensional (2D echocardiography. A total of 18 patients underwent two sequential gated SPECT acquisitions within 30 minutes in the resting state to assess repeatability. Another 28 patients who underwent gated SPECT and 2D echocardiography within 7 days were included for comparison. The two sequential measurements were well correlated with respect to LVEF, EDV, and ESV (r = 0.97, 0.95, and 0.97, respectively, all p < 0.0001. Bland-Altman analysis revealed that two standard deviations of the absolute difference between the two sequential measurements for LVEF, EDV, and ESV were 6.4%, 16.8 mL, and 8.6 mL, respectively. For LVEF, EDV, and ESV, correlations between redistribution 201Tl-gated SPECT and echocardiography were also excellent (all r = 0.83, p < 0.0001. LVEF was similar with 201Tl-gated SPECT and echocardiography, but EDV and ESV were significantly higher with echocardiography (p < 0.05. Our study revealed that 201Tl-gated SPECT has high repeatability and excellent correlation with echocardiography for the assessment of LVEF and volumes in Taiwanese. These results support the clinical application of gated SPECT in routine 201Tl myocardial perfusion imaging in Taiwanese.

  10. Renal MR angiography and perfusion in the pig using hyperpolarized water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling

    2016-01-01

    at 3 Tesla (T). Approximately 15 mL of hyperpolar-ized water was injected in the renal artery by hand over 4–5 s.Results: A liquid state polarization of 5.3 6 0.9% of 3.8 M pro-tons in 15 mL of deuterium oxide was achieved with a T1of24 6 1 s. This allowed injection through an arterial catheterinto...

  11. Association of left renal vein variations and pelvic varices in abdominal MDCT

    International Nuclear Information System (INIS)

    Koc, Zafer; Ulusan, Serife; Oguzkurt, Levent

    2007-01-01

    The aim of this study was to determine whether left renal vein (LRV) variation is associated with pelvic varices and left ovarian vein (LOV) reflux. Routine abdominal multidetector-row computed tomography scans of 324 women without symptoms of pelvic congestion syndrome were analyzed. Presence and type of LRV variants (circumaortic [CLRV] or retroaortic [RLRV]) were recorded. Diameters of the LRV, ovarian veins (OVs), and parauterine veins were measured and a specific LRV diameter ratio was calculated for each patient. Presence and severity of pelvic varices and LOV reflux were noted. Pelvic varices were detected in 59 (18%) of the total of 324 women, in 7 (37%) of the 19 women with RLRVs, in 7 (29%) of the 24 women with CLRVs, and in 45 (16%) of the 281 women with normal LRVs. The frequency of pelvic varices in the women with LRV variation was significantly higher than that in the group with normal LRV anatomy (33 vs. 16%; p=0.009). The frequency of pelvic varices in the women with RLRVs was also significantly higher than that in the group with normal LRV anatomy (p=0.02). LRV diameter ratio was correlated with presence of pelvic varices and presence of LOV reflux (p=0.0001 for both). This study revealed an association between pelvic varices and LRV variations in a population of predominantly multiparous women. (orig.)

  12. Association of left renal vein variations and pelvic varices in abdominal MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Zafer [Baskent University, Adana Teaching and Medical Research Center, Department of Radiology, Adana (Turkey); Baskent Universitesi Adana Hastanesi, Adana (Turkey); Ulusan, Serife; Oguzkurt, Levent [Baskent University, Adana Teaching and Medical Research Center, Department of Radiology, Adana (Turkey)

    2007-05-15

    The aim of this study was to determine whether left renal vein (LRV) variation is associated with pelvic varices and left ovarian vein (LOV) reflux. Routine abdominal multidetector-row computed tomography scans of 324 women without symptoms of pelvic congestion syndrome were analyzed. Presence and type of LRV variants (circumaortic [CLRV] or retroaortic [RLRV]) were recorded. Diameters of the LRV, ovarian veins (OVs), and parauterine veins were measured and a specific LRV diameter ratio was calculated for each patient. Presence and severity of pelvic varices and LOV reflux were noted. Pelvic varices were detected in 59 (18%) of the total of 324 women, in 7 (37%) of the 19 women with RLRVs, in 7 (29%) of the 24 women with CLRVs, and in 45 (16%) of the 281 women with normal LRVs. The frequency of pelvic varices in the women with LRV variation was significantly higher than that in the group with normal LRV anatomy (33 vs. 16%; p=0.009). The frequency of pelvic varices in the women with RLRVs was also significantly higher than that in the group with normal LRV anatomy (p=0.02). LRV diameter ratio was correlated with presence of pelvic varices and presence of LOV reflux (p=0.0001 for both). This study revealed an association between pelvic varices and LRV variations in a population of predominantly multiparous women. (orig.)

  13. Equivalent brain SPECT perfusion changes underlying therapeutic efficiency in pharmacoresistant depression using either high-frequency left or low-frequency right prefrontal rTMS.

    Science.gov (United States)

    Richieri, Raphaëlle; Boyer, Laurent; Padovani, Romain; Adida, Marc; Colavolpe, Cécile; Mundler, Olivier; Lançon, Christophe; Guedj, Eric

    2012-12-03

    Functional neuroimaging studies have suggested similar mechanisms underlying antidepressant effects of distinct therapeutics. This study aimed to determine and compare functional brain patterns underlying the antidepressant response of 2 distinct protocols of repetitive transcranial magnetic stimulation (rTMS). 99mTc-ECD SPECT was performed before and after rTMS of dorsolateral prefrontal cortex in 61 drug-resistant right-handed patients with major depression, using high frequency (10Hz) left-side stimulation in 33 patients, and low frequency (1Hz) right-side stimulation in 28 patients. Efficiency of rTMS response was defined as at least 50% reduction of the baseline Beck Depression Inventory score. We compared the whole-brain voxel-based brain SPECT changes in perfusion after rTMS, between responders and non-responders in the whole sample (pleft- and right-stimulation. Before rTMS, the left- and right-prefrontal stimulation groups did not differ from clinical data and brain SPECT perfusion. rTMS efficiency (evaluated on % of responders) was statistically equivalent in the two groups of patients. In the whole-group of responder patients, a perfusion decrease was found after rTMS, in comparison to non-responders, within the left perirhinal cortex (BA35, BA36). This result was secondarily confirmed separately in the two subgroups, i.e. after either left stimulation (p=0.017) or right stimulation (pbrain functional changes associated to antidepressive efficiency, consisting to a remote brain limbic activity decrease within the left perirhinal cortex. However, these results will have to be confirmed in a double-blind randomized trial using a sham control group. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. [Diffusion weighted imaging and perfusion weighted imaging in the differential diagnosis of benign and malignant renal masses on 3.0 T MRI].

    Science.gov (United States)

    Xu, Xiaowen; Wang, Peijun; Ma, Liang; Shao, Zhihong; Zhang, Min

    2015-01-20

    To explore the value of diffusion weighted imaging (DWI) and perfusion weighted imaging (PWI) in identifying benign and malignant renal masses and differentiating the histological types of renal masses. Fifteen healthy volunteers and 46 patients with renal masses proven by pathology, including clear cell carcinomas (n = 18), papillary carcinomas (n = 8), chromophobe carcinomas (n = 7) and angiomyolipomas (n = 13), were examined with DWI and PWI scan at 3.0 T MRI. ANOVA was employed to compare the values of transfer constant (K(trans)), rate constant of backflux (Kep) and extra-vascular extra-cellular space fractional volume (Ve) proceeded by PWI and the value of ADC resulted from DWI between normal kidney and different histological types of renal masses. Receiver operating characteristics (ROC) curve was used to analyze and compare the diagnostic value of the methods of PWI and DWI in differentiating benign and malignant renal masses. The ADC value of normal renal parenchyma was (2.10 ± 0.24) × 10⁻³ mm²/s, which was statistically higher than benign and malignant renal masses (P 0.05).Values of K(trans), Kep and Ve between normal renal parenchyma and different histological types of renal masses had statistical differences.Values of K(trans) and Ve in three histological types of malignant renal masses were statistically higher than those of benign renal masses.Kep value of clear cell carcinoma was significantly higher than that of benign renal masses (P benign and malignant renal masses. The K(trans) of benign and malignant renal masses had the largest AUC (AUC = 0.937) at a threshold of 0.38/min. And there were a sensitivity of 87.9% and a specificity of 85.7%. The AUC of ADC was 0.823, sensitivity 72.7% and specificity 92.9%. The ADC threshold for differentiating benign from malignant masses was 1.40 × 10⁻³ mm²/s; AUC of Ve 0.803, sensitivity 78.8% and specificity 71.4%, a threshold of 0.29/min; Kep showed lower diagnostic value. 3.0 T MRI DWI and PWI

  15. Magnetic Resonance Imaging-Derived Renal Oxygenation and Perfusion During Continuous, Steady-State Angiotensin-II Infusion in Healthy Humans.

    Science.gov (United States)

    van der Bel, René; Coolen, Bram F; Nederveen, Aart J; Potters, Wouter V; Verberne, Hein J; Vogt, Liffert; Stroes, Erik S G; Krediet, C T Paul

    2016-03-28

    The role of kidney hypoxia is considered pivotal in the progression of chronic kidney disease. A widely used method to assess kidney oxygenation is blood oxygen level dependent (BOLD)-magnetic resonance imaging (MRI), but its interpretation remains problematic. The BOLD-MRI signal is the result of kidney oxygen consumption (a proxy of glomerular filtration) and supply (ie, glomerular perfusion). Therefore, we hypothesized that with pharmacological modulation of kidney blood flow, renal oxygenation, as assessed by BOLD-MRI, correlates to filtration fraction (ie, glomerular filtration rate/effective renal plasma flow) in healthy humans. Eight healthy volunteers were subjected to continuous angiotensin-II infusion at 0.3, 0.9, and 3.0 ng/kg per minute. At each dose, renal oxygenation and blood flow were assessed using BOLD and phase-contrast MRI. Subsequently, "gold standard" glomerular filtration rate/effective renal plasma flow measurements were performed under the same conditions. Renal plasma flow decreased dose dependently from 660±146 to 467±103 mL/min per 1.73 m(2) (F[3, 21]=33.3, PMRI, we showed that cortical oxygenation measured by BOLD MRI relates poorly to glomerular filtration rate but is associated with filtration fraction. For future studies, there may be a need to include renal plasma flow measurements when employing renal BOLD-MRI. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  16. Human Umbilical Cord-Derived Mesenchymal Stromal Cells Improve Left Ventricular Function, Perfusion, and Remodeling in a Porcine Model of Chronic Myocardial Ischemia

    Science.gov (United States)

    Liu, Chuan-Bin; Huang, He; Sun, Ping; Ma, Shi-Ze; Liu, An-Heng; Xue, Jian; Fu, Jin-Hui; Liang, Yu-Qian; Liu, Bing; Wu, Dong-Ying

    2016-01-01

    Stem cell therapy has emerged as a new strategy for treatment of ischemic heart disease. Although umbilical cord-derived mesenchymal stromal cells (UC-MSCs) have been used preferentially in the acute ischemia model, data for the chronic ischemia model are lacking. In this study, we investigated the effect of UC-MSCs originated from Wharton’s jelly in the treatment of chronic myocardial ischemia in a porcine model induced by ameroid constrictor. Four weeks after ameroid constrictor placement, the surviving animals were divided randomly into two groups to undergo saline injection (n = 6) or UC-MSC transplantation (n = 6) through the left main coronary artery. Two additional intravenous administrations of UC-MSCs were performed in the following 2 weeks to enhance therapeutic effect. Cardiac function and perfusion were examined just before and at 4 weeks after intracoronary transplantation. The results showed that pigs with UC-MSC transplantation exhibited significantly greater left ventricular ejection fraction compared with control animals (61.3% ± 1.3% vs. 50.3% ± 2.0%, p UC-MSC treatment improves left ventricular function, perfusion, and remodeling in a porcine model with chronic myocardial ischemia. Significance Ischemic heart disease is the leading cause of death worldwide. Many patients with chronic myocardial ischemia are not suitable for surgery and have no effective drug treatment; they are called “no-option” patients. This study finds that umbilical cord-derived mesenchymal stromal cells transplanted by intracoronary delivery combined with two intravenous administrations was safe and could significantly improve left ventricular function, perfusion, and remodeling in a large-animal model of chronic myocardial ischemia, which provides a new choice for the no-option patients. In addition, this study used clinical-grade mesenchymal stem cells with delivery and assessment methods commonly used clinically to facilitate further clinical transformation. PMID

  17. Influence of magnification on the calculated value of left ventricular ejection fraction and volumes using quantitative gated perfusion SPECT

    International Nuclear Information System (INIS)

    Nunez, M.; Beretta, M.; Alonso, O.; Alvarez, B.; Canepa, J.; Mut, F.

    2002-01-01

    Aim: To compare left ventricular ejection fraction (LVEF), end-diastolic volumes (EDV) and end-systolic volumes (ESV) measured by quantitative gated SPECT (QGSPECT) in studies acquired with and without magnification factor (zoom). Material and Methods: We studied 30 consecutive patients (17 men, ages 61±14 years) referred for myocardial perfusion evaluation with a 2-day protocol. Studies were performed after injection of 925 MBq (25 mCi) of 99mTc-MIBI in the resting state. Gated SPECT was first acquired using a x2 zoom factor and immediately repeated with x1 zoom (no magnification), using a 64x64 matrix and 8 frames/cardiac cycle. Patients with arrhythmia were not included in the investigation. According to the median EDV calculated with the x2 zoom acquisition, the population was further divided in two sub-groups regarding the size of the LV cavity. Average LVEF, EDV, ESV and difference between values (delta) were then calculated for the total population and for each sub-group (a and b). Results: For the total population, results are expressed.Pearson correlation showed r=0.954 between LVEF with and without zoom (p<0.0001), but linear regression analysis did not fit a specific model (p=0.18). Median EDV with zoom was 92.5 ml, allowing to separate 15 cases with EDV above (a) and 15 below that value (b). Results for both sub-groups are presented. Conclusion: Calculated LVEF is higher with no zoom, at the expense of decreasing both EDV and ESV. Although differences were very significant for all parameters, ESV changes were specially relevant with no zoom, particularly in patients with smaller hearts. Although good correlation was found between LVEF with and without zoom, no specific correction factor was found to convert one value into the other. Magnification factor should be kept constant in gated SPECT if calculated LVEF values QGSPECT are expected to be reliable, and validation of the method using different zoom factors should be considered

  18. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera.

    Science.gov (United States)

    Shiraishi, Shinya; Sakamoto, Fumi; Tsuda, Noriko; Yoshida, Morikatsu; Tomiguchi, Seiji; Utsunomiya, Daisuke; Ogawa, Hisao; Yamashita, Yasuyuki

    2015-01-01

    Myocardial perfusion imaging (MPI) may fail to detect balanced ischemia. We evaluated myocardial perfusion reserve (MPR) using Tl dynamic single-photon emission computed tomography (SPECT) and a novel cadmium zinc telluride (CZT) camera for predicting 3-vessel or left main coronary artery disease (CAD). METHODS AND RESULTS: A total of 55 consecutive patients with suspected CAD underwent SPECT-MPI and coronary angiography. The MPR index was calculated using the standard 2-compartment kinetic model. We analyzed the utility of MPR index, other SPECT findings, and various clinical variables. On multivariate analysis, MPR index and history of previous myocardial infarction (MI) predicted left main and 3-vessel disease. The area under the receiver operating characteristic curve was 0.81 for MPR index, 0.699 for history of previous MI, and 0.86 for MPR index plus history of previous MI. MPR index ≤1.5 yielded the highest diagnostic accuracy. Sensitivity, specificity, and accuracy were 86%, 78%, and 80%, respectively, for MPR index, 64%, 76%, 73% for previous MI, and 57%, 93%, and 84% for MPR index plus history of previous MI. Quantification of MPR using dynamic SPECT and a novel CZT camera may identify balanced ischemia in patients with left main or 3-vessel disease.

  19. Incidental Anatomic Finding of Celiacomesenteric Trunk Associated with 'Nutcracker Phenomenon,' or Compression of the Left Renal Vein.

    Science.gov (United States)

    Peterson, Joshua; Hage, Anthony N; Diljak, Stephan; Long, Benjamin D; Marcusa, Daniel P; Stribley, John M; Brzezinski, David W; Eliason, Jonathan

    2017-12-15

    BACKGROUND Celiacomesenteric trunk (CMT) is a very rare anatomic finding in which the celiac artery and the superior mesenteric artery (SMA) originate from the abdominal aorta through a common trunk. Clinical associations with CMT include arterial aneurysm, thrombosis, and celiac artery compression. However, an association between CMT and abdominal venous congestion caused by left renal vein compression, or 'nutcracker phenomenon,' has not been previously reported. CASE REPORT A 91-year-old woman, who died from a cerebrovascular accident (CVA), underwent a cadaveric examination at our medical school. On examination of the abdomen, there was an incidental finding of CMT. The arterial and venous diameters were measured, and vascular histopathology was undertaken. The vascular anatomy was consistent with CMT type 1-b. Nutcracker phenomenon (NCP) (left renal vein compression) was seen anatomically as dilatation and engorgement of the left renal vein, relative to the right renal vein (10.77±0.13 mm vs. 4.49±0.56 mm, respectively), and dilatation and engorgement of the left ovarian vein, relative to the right ovarian vein (4.37±0.15 mm vs. 1.06±0.09 mm, respectively) with left ovarian varicocele. The aortoceliac angle (ACA) and the aortomesenteric angle (AMA) approached zero degrees. CONCLUSIONS We have described a rare anatomic finding of CMT that created an acute AMA and NCP. Awareness of this rare association between CMT and NCP by clinicians, vascular surgeons, and radiologists may be of value in the future evaluation and surgical management of patients who present clinically with 'nutcracker syndrome.'

  20. High coronary artery calcium score affects clinical outcome despite normal stress myocardial perfusion imaging and normal left ventricular ejection fraction

    DEFF Research Database (Denmark)

    Madsen, Claus Juul; Andersen, Kim F; Zerahn, Bo

    2013-01-01

    Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS and to id......Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS...

  1. Relations among impaired coronary flow reserve, left ventricular hypertrophy and thallium perfusion defects in hypertensive patients without obstructive coronary artery disease

    International Nuclear Information System (INIS)

    Houghton, J.L.; Frank, M.J.; Carr, A.A.; von Dohlen, T.W.; Prisant, L.M.

    1990-01-01

    Invasive Doppler catheter-derived coronary flow reserve, echocardiographic measurements of left ventricular hypertrophy and intravenous dipyridamole-limited stress thallium-201 scintigraphy were compared in 48 patients (40 were hypertensive or diabetic) with clinical ischemic heart disease and no or minor coronary artery disease. Abnormal vasodilator reserve (ratio less than 3:1) occurred in 50% of the study group and markedly abnormal reserve (less than or equal to 2:1) occurred in 27%. Coronary vasodilator reserve was significantly lower (2.2 +/- 0.8 versus 3.5 +/- 1.3, p = 0.003) and indexed left ventricular mass significantly higher (152.6 +/- 42.2 versus 113.6 +/- 24.0 g, p = 0.0007) in patients with a positive (n = 11) versus a negative (n = 32) thallium perfusion scan. Coronary flow reserve was linearly related in coronary basal flow velocity as follows: y = -0.17x + 4.59; r = -0.57; p = 0.00002. The decrement in flow reserve was not linearly related to the degree of left ventricular hypertrophy. Abnormal vasodilator reserve subsets found in hypertensive patients were defined on the basis of basal flow velocity, indexed left ventricular mass and clinical factors. In this series, diabetes did not cause a detectable additional decrement in flow reserve above that found with hypertension alone. These findings demonstrate that thallium perfusion defects are associated with depressed coronary vasodilator reserve in hypertensive patients without obstructive coronary artery disease. Left ventricular hypertrophy by indexed mass criteria is predictive of which hypertensive patients are likely to have thallium defects

  2. Analysis of intimal extent and predictors of renal atrophy in patients with aortic dissection

    International Nuclear Information System (INIS)

    Chan, Wen-Hui; Huang, Yu-Chieh; Wan, Yung-Liang; Weng, Hsu-Huei; Ko, Sheung-Fat; Chu, Jaw-Ji; Lin, Pyng-Jing

    2012-01-01

    Background: The intimal flap of aortic dissection may extend to the abdominal branches and probably lead to malperfusion syndrome. Renal malperfusion and renal atrophy are significantly related to patient outcomes. Purpose: To study the extent of the intimal flap and predisposing factors for renal atrophy in patients with aortic dissection. Material and Methods: From January 2001 to June 2008, 176 (137 men, aged 21-86 years, mean 51.9 years) of 225 subjects with aortic dissection and computed tomography (CT) met the inclusion criteria for this study. Of these 176 patients, 35 (19.9%) developed unilateral renal atrophy. A review of the CT was conducted to classify aortic branch vessel perfusion into three types: type 1, in which the branch vessels are perfused exclusively from the true lumen; type 2, in which the branches are perfused from both the true and false lumens; and type 3, in which the branches are perfused exclusively from the false lumen. Variables including age, gender, type of aortic dissection, type of perfusion of the abdominal branches, and the presence of thrombi in the false lumen were analyzed to determine whether these factors were related to the left or right side and global or focal renal atrophy. Results: Of 880 abdominal branches in 176 patients, 622 (70.7%) were classed as perfusion type 1, 50 (5.7%) as type 2, and 208 (23.6%) as type 3. Type 3 perfusion was most commonly observed in the left renal artery, at a frequency of 31.7% (66/208). Partial thrombosis in the false lumen above the level of the renal arteries was seen in 68.8% of patients; such thrombi and type 3 perfusion of the renal artery were significantly related to renal atrophy. The laterality (left or right) and extent (global or focal) of renal atrophy were not related to age, gender, type of aortic dissection, or perfusion type. Conclusion: Type 3 perfusion is most frequent in the left renal artery, and such perfusion and partial thrombi in the false lumen above the renal

  3. Analysis of intimal extent and predictors of renal atrophy in patients with aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wen-Hui; Huang, Yu-Chieh; Wan, Yung-Liang [Dept. of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Coll. of Medicine, Chang Gung Univ., Taoyuan, Taiwan (China)], e-mail: ylw0518@adm.cgmh.org.tw; Weng, Hsu-Huei [Dept. of Diagnostic Radiology, Chang Gung Memorial Hospital at Chia-Yi, Coll. of Medicine, Chang Gung Univ., Taoyuan, Taiwan (China); Ko, Sheung-Fat [Dept. of Diagnostic Radiology, Chang Gung Memorial Hospital at Kaohsiung, Coll. of Medicine, Chang Gung Univ., Taoyuan, Taiwan (China); Chu, Jaw-Ji; Lin, Pyng-Jing [Dept. of Cardiac Surgery, Chang Gung Memorial Hospital at Linkou, Coll. of Medicine, Chang Gung Univ., Taoyuan, Taiwan (China)

    2012-09-15

    Background: The intimal flap of aortic dissection may extend to the abdominal branches and probably lead to malperfusion syndrome. Renal malperfusion and renal atrophy are significantly related to patient outcomes. Purpose: To study the extent of the intimal flap and predisposing factors for renal atrophy in patients with aortic dissection. Material and Methods: From January 2001 to June 2008, 176 (137 men, aged 21-86 years, mean 51.9 years) of 225 subjects with aortic dissection and computed tomography (CT) met the inclusion criteria for this study. Of these 176 patients, 35 (19.9%) developed unilateral renal atrophy. A review of the CT was conducted to classify aortic branch vessel perfusion into three types: type 1, in which the branch vessels are perfused exclusively from the true lumen; type 2, in which the branches are perfused from both the true and false lumens; and type 3, in which the branches are perfused exclusively from the false lumen. Variables including age, gender, type of aortic dissection, type of perfusion of the abdominal branches, and the presence of thrombi in the false lumen were analyzed to determine whether these factors were related to the left or right side and global or focal renal atrophy. Results: Of 880 abdominal branches in 176 patients, 622 (70.7%) were classed as perfusion type 1, 50 (5.7%) as type 2, and 208 (23.6%) as type 3. Type 3 perfusion was most commonly observed in the left renal artery, at a frequency of 31.7% (66/208). Partial thrombosis in the false lumen above the level of the renal arteries was seen in 68.8% of patients; such thrombi and type 3 perfusion of the renal artery were significantly related to renal atrophy. The laterality (left or right) and extent (global or focal) of renal atrophy were not related to age, gender, type of aortic dissection, or perfusion type. Conclusion: Type 3 perfusion is most frequent in the left renal artery, and such perfusion and partial thrombi in the false lumen above the renal

  4. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Toyama, Takuji [Department of Cardiovascular Medicine, Gunma Prefectural Cardiovascular Center, Maebashi (Japan); Sato, Makito [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Tatebayashi Kosei Hospital, Department of Internal Medicine, Gunma (Japan); Sano, Hirokazu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Isesaki Municipal Hospital, Department of Cardiovascular Medicine, Isesaki (Japan); Ueda, Tetsuya [Fujioka General Hospital, Division of Cardiology, Fujioka (Japan); Sasaki, Toyoshi [Takasaki General Medical Center, Division of Cardiology, Takasaki (Japan); Nakahara, Takehiro; Kurabayashi, Masahiko [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Higuchi, Tetsuya; Tsushima, Yoshito [Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi (Japan)

    2016-02-15

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m{sup 2}] undergoing stress {sup 99m}Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  5. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    International Nuclear Information System (INIS)

    Kasama, Shu; Toyama, Takuji; Sato, Makito; Sano, Hirokazu; Ueda, Tetsuya; Sasaki, Toyoshi; Nakahara, Takehiro; Kurabayashi, Masahiko; Higuchi, Tetsuya; Tsushima, Yoshito

    2016-01-01

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m 2 ] undergoing stress 99m Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  6. Effect of Hemodialysis on Eye Coats, Axial Length, and Ocular Perfusion Pressure in Patients with Chronic Renal Failure

    Directory of Open Access Journals (Sweden)

    Ling Wang

    2018-01-01

    Full Text Available Purpose. To investigate changes in eye coats, axial length, and ocular perfusion pressure (OPP in hemodialysis (HD patients with chronic renal failure (CRF. Methods. We included HD patients who were diagnosed with CRF in our hospital from January to December 2015. Fifty-two patients met the inclusion criteria; all right eyes were used for observation. Systolic and diastolic blood pressures were recorded to calculate OPP. Approximately 30 minutes before and after HD, we recorded multiple parameters, including lens thickness (LT, axial length of vitreous (VAL, axial length of eye (EAL, ciliary body thickness (CBT, choroidal thickness (CT, and retinal thickness (RT. Results. After HD, OPP significantly decreased (P<0.01, F=7.023 and CBT became significantly thinner (P<0.01, t=3.461. CT was significantly thinner and differed among measurement locations (P<0.01, t=6.240; P<0.01, t=6.169; P<0.01, t=3.405, respectively, fovea, nasal, and temporal side 1500 μm beside the fovea. Further, RT thickened and differed among measurement locations (P<0.05, t=−2.265; P<0.05, t=−2.624; P<0.05, t=−2.220, respectively, fovea, nasal, and temporal side 1500 μm beside fovea, whereas LT, VAL, and EAL significantly increased after HD (P<0.05, t=−2.076; P<0.01, t=−3.817; P<0.01, t=−4.010. Conclusions. HD impacts the thickness of the eye coats and VAL, particularly affecting CBT, CT, and RT. OPP transiently decreases during HD, which may contribute to an ischemic state.

  7. Posterior Nutcracker Syndrome with Left Renal Vein Duplication: A Rare Cause of Haematuria in a 12-Year-Old Boy

    Directory of Open Access Journals (Sweden)

    J. Preza Fernandes

    2012-01-01

    Full Text Available The nutcracker syndrome (NCS is a rare cause of haematuria. It embraces an extended nonpathognomonic spectrum of symptoms that imply a difficult diagnosis. Ultimately it may be associated with substantial morbidity and even life-threatening events. We report a rare cause if a 12-year-old boy who presented with a history of frequent intermittent episodes of painless constant haematuria. The cystoscopy showed a bloody urine ejaculate from the left ureter meatus. The Doppler ultrasonography showed turbulent pattern of venous blood flow of the posterior renal vein branch behind the aorta. The abdominopelvic computer tomography (apCT revealed left renal vein (LRV duplication with a dilated retroaortic branch, entrapped between the aorta and the vertebral column, promoting the renal nutcracker syndrome. The patient was initially hospitalized and managed with oral iron supplements and continuous saline bladder irrigation, not requiring additional treatment. The child is currently asymptomatic, with haemoglobin value returning to normal and therefore proposed to conservative management with close followup. The authors present a case report of episodic haematuria caused by a rare entity—posterior nutcracker syndrome with renal vein duplication.

  8. Prediction of left ventricular ejection fraction in patients with coronary artery disease based on an analysis of perfusion patterns at rest. Assessment by an artificial neural network

    International Nuclear Information System (INIS)

    Stefaniak, B.; Cholewinski, W.; Tarkowska, A.

    2004-01-01

    In CAD, left ventricular function depends on the condition of myocardial perfusion, hence it may be presumed that blood flow abnormalities may enable the LVEF to be predicted. The aim of the study was to apply an Artificial Neural Network (ANN) to investigate the relationships between myocardial perfusion and LVEF, measured simultaneously. gSPECT examinations were performed in 95 patients with CAD, divided into training (n = 50) and testing (n = 45) groups. using the acquired data, in each subject the LVEF was calculated and a perfusion polar map was constructed and divided into 25 segments. Based on results obtained in the training group, a characteristic configuration of segments was defined, with features enabling differentiation between the individual subjects of that group. The set of those segments, as well as the corresponding LVEF values enabled the optimum network architecture to be constructed and trained. The trained ANN was verified by application to the testing group. Using the above-described procedure, 15 polar map segments were defined which enabled the patients of the training group to be differentiated sufficiently enough to make their further recognition possible. The optimal network structure consisting 25 neurons was obtained by comparing the activity in those segments in individual subjects with corresponding LVEF values. Based on the above model, the obtained network was able to reproduce learning data (r = 0.832; learning error 4.84%) and to apply the gained knowledge to the testing cases (r = 0.786; testing error = 4.99%). The obtained network can generalise learned information. To predict LVEF, some polar map segments should be excluded from the analysis. Erroneous LVEF prediction may occur resulting mainly from conditions independent from perfusion abnormalities. (author)

  9. Unusual complication after laparoscopic left nephrectomy for renal tumour: a case report

    Directory of Open Access Journals (Sweden)

    Arantxa Arruabarrena

    2010-06-01

    Full Text Available In splenic rupture after blunt trauma, iatrogenic spleen injury or non-traumatic cases it is essential that the surgeonmakes correct decisions. Conservative treatment must include continual monitoring and repeated, stringent evaluationof the splenic injury (the American Association for the Surgery of Trauma – AAST in order to avoid any delay indiagnosis of delayed spleen rupture and the high mortality it causes. We present the case of an unexpected complicationafter radical nephrectomy performed for renal cell carcinoma. A 61-year old man sought medical help for acuteabdominal pain. He presented with some cardiovascular risk factors (diabetes mellitus, smoker of 30 cigarettes perday and moderate alcohol use. In the Emergency Unit, computed tomography scan revealed an incidental tumour ofthe left kidney. Nephrectomy via the laparoscopic approach was done without any iatrogenic complications, with lessthan 500 cc of blood loss. Firm adhesions between the spleen and abdominal wall, which caused some minor tractionthat resulted in a small subcapsular haematoma, were the only surprising intraoperative finding. Within the first 6 h,the patient presented with haemodynamic instability, while the drain evacuated less than 50 cc of discharge.However, CT scan showed that subcapsular haematoma had increased to the size of 10 × 10 cm without freeperitoneal fluid present. Unfortunately, 6 h later emergency surgery had to be performed due to rupture of thesubcapsular splenic haematoma. Massive haemoperitoneum was evacuated and the splenic capsule was the onlyremnant of the spleen that could be found on re-intervention. So far, it is the first case describing an increasing subcapsularhaematoma of the spleen, most likely caused by the traction of firm adhesions to the organ. We discussmeans to avoid such a complication: with liberation of the adhesions, placement of a perisplenic mesh, embolizationof the splenic artery or subcapsular nephrectomy. An acute

  10. Role of adenosine 99MTc sestamibi myocardial perfusion spect in evaluation of symptomatic hypertensives with recent onset left bundle branch block

    International Nuclear Information System (INIS)

    Padma, S.; Sundaram, P.S.; Zachariah, M.; Hariads, K.K.

    2004-01-01

    Objectives: Adenosine pharmacological stress Myocardial Perfusion Imaging (AMPI) is the preferred imaging modality for IHD evaluation in pts with Left Bundle Branch Block (LBBB). Good prognosis has been reported in recent onset LBBB pts with normal MPI. Our aim was to evaluate the utility and analyze the predictive value of SestaMIBI AMPI in symptomatic recent onset LBBB hypertensives for coronary artery disease evaluation. Methods: 29 hypertensive pts, age range 36-72yrs, mean 54+ 6 yrs, M:F- 21:8 with recent onset complete LBBB, under evaluation for typical/atypical angina who had AMPI between Nov 02-Nov 03, were retrospectively analyzed. LBBB was diagnosed ECG wise if there is prolonged QRS complex i.e. 0.125sec or more in sinus/supraventricular rhythm, a QS or rS complex in lead 1, and an R-wave peak time of 0.06sec in leads 1, V5 or V6 with no Q wave in same lead. Pts with prior Myocardial Infarct / revasularisation, pacemaker induced LBBB were excluded. Single day 6 min. Adenosine infusion Stress-rest 99m Tc MIBI gated MPI was performed with a dual head variable angle Gamma Camera at 76-degree angle. Coronary Angiogram (CAG) correlation was available in 24 pts. Results: Myocardial perfusion SPECT images were assessed visually and by a 20-segment model. Location, extent and severity of the LV perfusion defects were evaluated. 6/29 pts (20.7%) had normal stress-rest perfusion in all LV segments.12 (41.4%) had isolated septal fixed defect with normal perfusion in rest of the segments.3 pts (10.3%)showed isolated reversible septal defects while 8(27.6%) had reversible septal defects with reversible defects in other LV segments also. Pts with fixed septal perfusion defect showed moderate to good septal wall thickening in gated SPECT images. While all pts with multiple reversible perfusion defects had angiographically proven coronary artery disease (i.e. 3pts had LAD lesion, 2 had Triple vessel and 3 showed double vessel lesions), 1 out of 3 pts with isolated

  11. Iterative study of renal functions by the continuous perfusion of radioactive tracers before and after the initiation of treatment for diabetes mellitus and hypertension

    International Nuclear Information System (INIS)

    Mirouze, J.; Monnier, L.; Olivier, C.

    1975-01-01

    Glomerular filtration and renal plasma flux are measured simultaneously as a result of achieving isotopic equilibrium after the continuous perfusion of 125 I-iothalamate and 131 I-orthoiodohippurate. A good correlation is found between the clearances of 125 I-iothalamate (y) and of inulin or polyfructosan (x): y = 1.18 x + 8.43 (r 0.96; P 131 I-orthoiodohippurate (y') and para-aminohippuric acid (x'): y' = 0.62 x' + 21.2 (r = 0.93; P < 0.001). When the renal function is modified, the iothalamate is not suitable for this technique since the time necessary to reach a radioactive concentration plateau exceeds three hours. Orthoiodohippurate, on the contrary, yields good results. The main advantages of the method in this case are absence of urine collection and rapid achievement of isotopic equilibrium. The repeated study of the renal function of hypertensive patients and of diabetics makes it possible to investigate the effects of anti-hypertension drugs and insulin therapy. Since clonidin improves the clearances slightly, it may be considered for administration in cases of hypertension associated with chronic renal inadequacy. Insulin therapy very rapidly increases the glomerular filtration and renal plasma flux of diabetics by insulin extraction. This improvement depends more on metabolic and haemodynamic changes caused by the insulin than on the correction of disorders affecting the permeability of the basal glomerular membrane

  12. Coronary perfusion pressure and compression quality in maternal cardiopulmonary resuscitation in supine and left-lateral tilt positions: A prospective, crossover study using mannequins and swine models.

    Science.gov (United States)

    Dohi, Satoshi; Ichizuka, Kiyotake; Matsuoka, Ryu; Seo, Kohei; Nagatsuka, Masaaki; Sekizawa, Akihiko

    2017-09-01

    The risk of maternal and fetal mortality is high if cardiopulmonary arrest occurs during pregnancy. To assess the best position for maternal cardiopulmonary resuscitation (CPR), a prospective randomized crossover study was undertaken, involving basic life support mannequin-based simulation (BLS-MS) and a swine model of pulseless electrical activity (an unstable cardiac state) incorporating a fetal mannequin (PEA-FM). The BLS-MS (performed by certified rescuers) served to evaluate the quality of chest compressions in 30° left lateral tilt (LLT) and supine positions. Based on a 5-point scale, each rescuer subjectively graded their experience. The PEA-FM model was used to compare coronary perfusion pressure readings during CPR in supine, supine with left uterine displacement, 30° LLT, and 30° right lateral tilt positions. Compression rate and correctness of hand position, compression depth, and recoil were measures of compression quality (BLS-MS). Compared with LLT position, supine position enabled correct hand position (rate: 0.99 vs 0.88; p<0.05) and compression depth (rate: 0.76 vs 0.36; p<0.001) significantly more often. Moreover, BLS-MS rescuers found chest compressions significantly easier to perform with the mannequin in supine (vs LLT) position (difficulty score: 1.75 vs 3.95; p<0.001). In the PEA-FM study arm, supine position with left uterine displacement and right lateral tilt positions had the highest and lowest recorded coronary perfusion pressure readings, respectively. Supine position with left uterine displacement is optimal for maternal CPR. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  13. Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure

    Science.gov (United States)

    Shojaeifard, Maryam; Ghaedian, Tahereh; Yaghoobi, Nahid; Malek, Hadi; Firoozabadi, Hasan; Bitarafan-Rajabi, Ahmad; Haghjoo, Majid; Amin, Ahmad; Azizian, Nasrin; Rastgou, Feridoon

    2015-01-01

    Background: Gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is known as a feasible tool for the measurement of left ventricular ejection fraction (EF) and volumes, which are of great importance in the management and follow-up of patients with coronary artery diseases. However, considering the technical shortcomings of SPECT in the presence of perfusion defect, the accuracy of this method in heart failure patients is still controversial. Objectives: The aim of the present study was to compare the results from gated SPECT MPI with those from echocardiography in heart failure patients to compare echocardiographically-derived left ventricular dimension and function data to those from gated SPECT MPI in heart failure patients. Patients and Methods: Forty-one patients with severely reduced left ventricular systolic function (EF ≤ 35%) who were referred for gated SPECT MPI were prospectively enrolled. Quantification of EF, end-diastolic volume (EDV), and end-systolic volume (ESV) was performed by using quantitative gated spect (QGS) (QGS, version 0.4, May 2009) and emory cardiac toolbox (ECTb) (ECTb, revision 1.0, copyright 2007) software packages. EF, EDV, and ESV were also measured with two-dimensional echocardiography within 3 days after MPI. Results: A good correlation was found between echocardiographically-derived EF, EDV, and ESV and the values derived using QGS (r = 0.67, r = 0.78, and r = 0.80 for EF, EDV, and ESV, respectively; P echocardiography. ECTb-derived EDV was also significantly higher than the EDV measured with echocardiography and QGS. The highest correlation between echocardiography and gated SPECT MPI was found for mean values of ESV different. Conclusions: Gated SPECT MPI has a good correlation with echocardiography for the measurement of left ventricular EF, EDV, and ESV in patients with severe heart failure. However, the absolute values of these functional parameters from echocardiography and gated

  14. Impact of right-ventricular apical pacing on the optimal left-ventricular lead positions measured by phase analysis of SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Hung, Guang-Uei; Huang, Jin-Long; Lin, Wan-Yu; Tsai, Shih-Chung; Wang, Kuo-Yang; Chen, Shih-Ann; Lloyd, Michael S.; Chen, Ji

    2014-01-01

    The use of SPECT phase analysis to optimize left-ventricular (LV) lead positions for cardiac resynchronization therapy (CRT) was performed at baseline, but CRT works as simultaneous right ventricular (RV) and LV pacing. The aim of this study was to assess the impact of RV apical (RVA) pacing on optimal LV lead positions measured by SPECT phase analysis. This study prospectively enrolled 46 patients. Two SPECT myocardial perfusion scans were acquired under sinus rhythm with complete left bundle branch block and RVA pacing, respectively, following a single injection of 99m Tc-sestamibi. LV dyssynchrony parameters and optimal LV lead positions were measured by the phase analysis technique and then compared between the two scans. The LV dyssynchrony parameters were significantly larger with RVA pacing than with sinus rhythm (p ∝0.01). In 39 of the 46 patients, the optimal LV lead positions were the same between RVA pacing and sinus rhythm (kappa = 0.861). In 6 of the remaining 7 patients, the optimal LV lead positions were along the same radial direction, but RVA pacing shifted the optimal LV lead positions toward the base. The optimal LV lead positions measured by SPECT phase analysis were consistent, no matter whether the SPECT images were acquired under sinus rhythm or RVA pacing. In some patients, RVA pacing shifted the optimal LV lead positions toward the base. This study supports the use of baseline SPECT myocardial perfusion imaging to optimize LV lead positions to increase CRT efficacy. (orig.)

  15. Myocardial perfusion and left ventricular function during exercise evaluated by 201Tl myocardial scintigraphy and 99mTc radionuclide ventriculography in patients treated with PTCA

    International Nuclear Information System (INIS)

    Honda, Toshio; Jo, Tadafumi; Doiuchi, Junji

    1992-01-01

    To evaluate the effects of percutaneous transluminal coronary angioplasty (PTCA), we investigated myocardial ischemia and left ventricular function during exercise before and after successful PTCA in 30 patients. We used extent and severity scores of 201 thallium ( 201 Tl) exercise myocardial scintigraphy to assess myocardial ischemia and determined global and regional left ventricular ejection fraction (EF and REF) of 99m Tc-RBC exercise radionuclide ventriculography to assess left ventricular function. The extent and severity scores of stress images were significantly less after PTCA than before PTCA. The scores of the redistribution images were unchanged before and after PTCA. Global EF during exercise was significantly higher after PTCA than before PTCA. There was no difference in resting global EF between before and after PTCA. Myocardial ischemia induced by exercise was semi-quantitatively analyzed as transient perfusion defect with severity score. Severity score was significantly less after PTCA than before PTCA. ΔEF, which was obtained by subtraction of resting global EF from exercise one, was significantly higher after PTCA than before PTCA. However, the degree of improvement in myocardial ischemia and left ventricular function varied from patient to patient. In 17 patients with one-vessel left anterior descending artery disease, ΔREF, which was determined by subtracting resting regional EF from exercise one, was significantly higher in septal and apical segments after PTCA than before PTCA. Myocardial ischemia and left ventricular function under exercise were alleviated by PTCA. However, the degree of improvement varied from patient to patient and it might have been affected by various factors including coronary dissection, edema, thrombus, restenosis, spasm, side branch stenosis or occlusion, distal thrombus, and myocardial hibernation. (author)

  16. Diagnosis of nutcracker syndrome of the left renal vein. Value of the corticomedullary phase of helical CT

    International Nuclear Information System (INIS)

    Igari, Hidenori

    2001-01-01

    The clinical significance of the corticomedullary phase of helical CT in the diagnosis of nutcracker syndrome of the left renal vein (LRV) was evaluated. A total of 38 patients with hematuria of unknown origin (12 men and 26 women, mean age 24 years [range: 18-32 years]) were examined by helical CT of the kidneys, retrograde left renal venography, and measurement of renocaval pressure gradients. The sensitivity and specificity of the corticomedullary and nephrographic phases of helical CT for detecting the nutcracker syndrome were determined. The nutcracker syndrome was diagnosed on the basis of the renography findings combined with pressure measurements in 19 patients: 12 with LRV hypertension and collateral veins, 1 with hypertension and no collateral veins, and 6 with collateral veins and normal pressure gradients or borderline hypertension. Both the corticomedullary- and nephrographic-phase images revealed distended LRVs in 26 (68%) of the 38 patients. The LRV mean attenuation values in the corticomedullary phase (164±22 Hounsfield units [H], range: 138-209 H) was significantly greater (p<0.001) than in the nephrographic phase (80±14 H, range: 62-100 H). During the corticomedullary phase, opacified blood from the renal vein was mixed with unopacified blood in the IVC. In the nephrographic phase, however, the IVC was enhanced homogeneously, but only slightly. Corticomedullary-phase imaging detected collateral veins that exhibited early enhancement, indicating retrograde flow from the LRVs in 15 out of 18 patients (83% of those with collateral veins), while the nephrographic-phase imaging revealed collateral veins in 8 patients (44% of those with collateral veins). The sensitivity and specificity of the corticomedullary-phase scan for detecting the nutcracker syndrome were 79% and 100%, respectively, as opposed to 42% and 100%, respectively, for the nephrographic phase. Retrograde flow from the LRV into the collateral veins in the corticomedullary phase is a

  17. Use of Contrast-Enhanced Ultrasound to Study Relationship between Serum Uric Acid and Renal Microvascular Perfusion in Diabetic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Ling Wang

    2015-01-01

    Full Text Available Purpose. To investigate the relationship between uric acid and renal microvascular perfusion in diabetic kidney disease (DKD using contrast-enhanced ultrasound (CEUS method. Materials and Methods. 79 DKD patients and 26 healthy volunteers were enrolled. Renal function and urine protein markers were tested. DKD patients were subdivided into two groups including a normal serum uric acid (SUA group and a high SUA group. Contrast-enhanced ultrasound (CEUS was performed, and low acoustic power contrast-specific imaging was used for quantitative analysis. Results. Normal controls (NCs had the highest levels of AUC, AUC1, and AUC2. Compared to the normal SUA DKD group, high SUA DKD patients had significantly higher IMAX, AUC, and AUC1 (P<0.05. DKD patients with low urinary uric acid (UUA excretion had significantly higher AUC2 compared to DKD patients with normal UUA (P<0.05. Conclusion. Hyperuricemia in DKD patients was associated with a renal ultrasound image suggestive of microvascular hyperperfusion. The CEUS parameter AUC1 holds promise as an indicator for renal microvascular hyperperfusion, while AUC2 might be a useful indicator of declining glomerular filtration rate in DKD patients with decreased excretion of uric acid.

  18. Impact of intracoronary injection of mononuclear bone marrow cells in acute myocardial infarction on left ventricular perfusion and function: a 6-month follow-up gated 99mTc-MIBI single-photon emission computed tomography study

    International Nuclear Information System (INIS)

    Lipiec, Piotr; Krzeminska-Pakula, Maria; Plewka, Michal; Kasprzak, Jaroslaw D.; Kusmierek, Jacek; Plachcinska, Anna; Szuminski, Remigiusz; Robak, Tadeusz; Korycka, Anna

    2009-01-01

    We investigated the impact of intracoronary injection of autologous mononuclear bone marrow cells (BMC) in patients with acute ST elevation myocardial infarction (STEMI) on left ventricular volumes, global and regional systolic function and myocardial perfusion. The study included 39 patients with first anterior STEMI treated successfully with primary percutaneous coronary intervention. They were randomly assigned to the treatment group or the control group in a 2:1 ratio. The patients underwent baseline gated single-photon emission computed tomography (G-SPECT) 3-10 days after STEMI with quantitative and qualitative analysis of left ventricular perfusion and systolic function. On the following day, patients from the BMC treatment group were subjected to bone marrow aspiration, mononuclear BMC isolation and intracoronary injection. No placebo procedure was performed in the control group. G-SPECT was repeated 6 months after STEMI. Baseline and follow-up G-SPECT studies were available for 36 patients. At 6 months in the BMC group we observed a significantly enhanced improvement in the mean extent of the perfusion defect, the left ventricular perfusion score index, the infarct area perfusion score and the infarct area wall motion score index compared to the control group (p=0.01-0.04). However, the changes in left ventricular volume, ejection fraction and the left ventricular wall motion score index as well as the relative changes in the infarct area wall motion score index did not differ significantly between the groups. Intracoronary injection of autologous mononuclear BMC in patients with STEMI improves myocardial perfusion at 6 months. The benefit in infarct area systolic function is less pronounced and there is no apparent improvement of global left ventricular systolic function. (orig.)

  19. Longitudinal Assessment of Renal Perfusion and Oxygenation in Transplant Donor-Recipient Pairs Using Arterial Spin Labeling and Blood Oxygen Level-Dependent Magnetic Resonance Imaging.

    Science.gov (United States)

    Niles, David J; Artz, Nathan S; Djamali, Arjang; Sadowski, Elizabeth A; Grist, Thomas M; Fain, Sean B

    2016-02-01

    The aims of this study were to assess renal function in kidney transplant recipients and their respective donors over 2 years using arterial spin labeling (ASL) and blood oxygen level-dependent (BOLD) magnetic resonance imaging (MRI) and to prospectively evaluate the effect of losartan on functional MRI measures in recipients. The study included 15 matched pairs of renal transplant donors and recipients. Arterial spin labeling and BOLD MRI of the kidneys were performed on donors before transplant surgery (baseline) and on both donors and recipients at 3 months, 1 year, and 2 years after transplant. After 3 months, 7 of the 15 recipients were prescribed 25 to 50 mg/d losartan for the remainder of the study. A linear mixed-effects model was used to evaluate perfusion, R2*, estimated glomerular filtration rate, and fractional excretion of sodium for changes across time or associated with losartan treatment. In donors, cortical perfusion in the remaining kidney decreased by 50 ± 19 mL/min per 100 g (11.8%) between baseline and 2 years (P donors and to 14.6 ± 4.3 mL/min per 1.73 m (33.3%; P donors, and they indicate a potentially beneficial effect of losartan in recipients.

  20. Resting electrocardiogram and stress myocardial perfusion imaging in the determination of left ventricular systolic function: an assessment enhancing the performance of gated SPET.

    Science.gov (United States)

    Moralidis, Efstratios; Spyridonidis, Tryfon; Arsos, Georgios; Skeberis, Vassilios; Anagnostopoulos, Constantinos; Gavrielidis, Stavros

    2010-01-01

    This study aimed to determine systolic dysfunction and estimate resting left ventricular ejection fraction (LVEF) from information collected during routine evaluation of patients with suspected or known coronary heart disease. This approach was then compared to gated single photon emission tomography (SPET). Patients having undergone stress (201)Tl myocardial perfusion imaging followed by equilibrium radionuclide angiography (ERNA) were separated into derivation (n=954) and validation (n=309) groups. Logistic regression analysis was used to develop scoring systems, containing clinical, electrocardiographic (ECG) and scintigraphic data, for the discrimination of an ERNA-LVEFstatistic (mean+/-2SD) provided values of 0.001+/-0.176, 0.071+/-0.196 and 0.040+/-0.152, respectively. The average LVEF was a better discriminator of systolic dysfunction than gated SPET-LVEF in receiver operating characteristic (ROC) analysis and identified more patients (89%) with a stress myocardial perfusion imaging variables. This model provides reliable LVEF estimations, comparable to those from (201)Tl gated SPET, and can enhance the clinical performance of the latter.

  1. Impaired left ventricular systolic function and increased brachial-ankle pulse-wave velocity are independently associated with rapid renal function progression.

    Science.gov (United States)

    Chen, Szu-Chia; Lin, Tsung-Hsien; Hsu, Po-Chao; Chang, Jer-Ming; Lee, Chee-Siong; Tsai, Wei-Chung; Su, Ho-Ming; Voon, Wen-Chol; Chen, Hung-Chun

    2011-09-01

    Heart failure and increased arterial stiffness are associated with declining renal function. Few studies have evaluated the association between left ventricular ejection fraction (LVEF) and brachial-ankle pulse-wave velocity (baPWV) and renal function progression. The aim of this study was to assess whether LVEFfunction was estimated by eGFR slope. The renal end point was defined as ≥25% decline in eGFR. Clinical and echocardiographic parameters were compared and analyzed. After a multivariate analysis, serum hematocrit was positively associated with eGFR slope, and diabetes mellitus, baPWV (P=0.031) and LVEFfunction decline and progression to the renal end point.

  2. Hepatic and renal function with successful long-term support on a continuous flow left ventricular assist device.

    Science.gov (United States)

    Deo, Salil V; Sharma, Vikas; Altarabsheh, Salah E; Hasin, Tal; Dillon, John; Shah, Ishan K; Durham, Lucian A; Stulak, John M; Daly, Richard C; Joyce, Lyle D; Park, Soon J

    2014-03-01

    Data regarding the long-term clinical effects of a continuous flow left ventricular assist device (CF-LVAD) on hepato-renal function is limited. Hence our aim was to assess changes in hepato-renal function over a one-year period in patients supported on a CF-LVAD. During the study period 126 patients underwent CF-LVAD implant. Changes in hepato-renal laboratory parameters were studied in 61/126 patients successfully supported on a CF-LVAD for period of one year. A separate cohort of a high-risk group (HCrB) of patients (56/126) with a serum creat>1.9 mg/dL (168 μmol/L) (75th percentile) or a serum bil>1.5 mg/dL (25.65 μmol/L) (75th percentile) was created. Changes in serum creatinine and bilirubin were analysed at regular intervals for this group along with the need for renal replacement therapy. Baseline creatinine and blood urea nitrogen (BUN) for the entire cohort was 1.4[1.2,1.9 mg/dL] [123.7(106,168) μmol/L) and 27[20,39.5 mg/dL] [9.6(7.1,14.1) mmol/L] respectively. After an initial reduction at the end of one month [1(0.8,1.2) mg/dL; 88(70,105) μmol/L] (passist device support for one year. High-risk patients demonstrate a higher 30-day mortality and temporary need for renal replacement therapy. Yet even in this cohort, improvement is present over a period of one year on the device, with a minimal need for permanent haemodialysis. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  3. Pulmonary perfusion ''without ventilation''

    International Nuclear Information System (INIS)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-01-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  4. CT perfusion imaging in the management of posterior reversible encephalopathy

    International Nuclear Information System (INIS)

    Casey, S.O.; McKinney, A.; Teksam, M.; Liu, H.; Truwit, C.L.

    2004-01-01

    A 13-year-old girl with a renal transplant presented with hypertension and seizures. CT and MRI demonstrated typical bilateral parietal, occipital and posterior frontal cortical and subcortical edema, thought to represent posterior reversible encephalopathy syndrome. The cause was presumed to be hypertension. Antihypertensive therapy was started, lowering of the blood pressure in the range of 110-120 mmHg systolic. However, stable xenon (Xe) CT perfusion imaging revealed ischemia within the left parietal occipital region. The antihypertensive was adjusted which increased both the systolic and diastolic blood pressure by 31 mm Hg. The patient was re-imaged with Xe CT and was found to have resolution of the ischemic changes within the left parietal occipital region. In this report, we present a case in which stable Xe CT was used to monitor the degree of cerebral perfusion and guide titration of antihypertensive therapy. Such brain perfusion monitoring may have helped to prevent infarction of our patient. (orig.)

  5. Exercise thallium-201 imaging in complete left bundle branch block and the prevalence of septal perfusion defects

    International Nuclear Information System (INIS)

    Jazmati, B.; Sadaniantz, A.; Emaus, S.P.; Heller, G.V.

    1991-01-01

    To determine the prevalence of septal defects in a generalized referral population, the records of 93 consecutive patients with complete left bundle branch block (BBB) who underwent symptom-limited treadmill exercise testing with thallium-201 myocardial imaging over a 3-year period were reviewed. Segmental analysis of the planar thallium-201 images was performed in a blinded fashion with agreement by consensus. Computerized quantitative analysis of the images also was independently performed, and was correlated with the visual interpretations. Forty-seven patients (51%) had normal images, and 46 (49%) had defects of greater than or equal to 2 segments. In the abnormal studies, only 13 patients (14% of the total population) had septal defects, while a much higher number of patients, 33 (39%), had inferior or apical defects, or both. Coronary angiography was performed in 6 patients with septal defects: Significant narrowing of the left anterior descending coronary artery was found in 4 patients, a narrowed right coronary artery was found in 1, and normal coronary arteries were seen in the other patient. In conclusion, whereas previous studies have suggested a high percentage of false-positive septal defects in patients with left BBB, this study demonstrates a low prevalence (14%) of septal defects in a large population of unselected patients presenting for exercise thallium-201 imaging. Therefore, exercise thallium-201 imaging remains a useful procedure for evaluating patients with complete left BBB

  6. Prognostic importance of renal function in patients with early heart failure and mild left ventricular dysfunction

    NARCIS (Netherlands)

    Smilde, Tom; Hillege, Hans; Voors, Adriaan; Dunselman, P.H.J.; Van Veldhuisen, D.J.

    2004-01-01

    We evaluated the prognostic value of renal function in an initially “untreated” population with mild heart failure and compared the prognosis of this population with a matched controlled population. During a follow-up of 13 years (mean 11.7), 90 patients (56%) died. Mortality was higher compared

  7. Perfusion dyssynchrony analysis

    NARCIS (Netherlands)

    Chiribiri, A.; Villa, A.D.M.; Sammut, E.; Breeuwer, M.; Nagel, E.

    2015-01-01

    AIMS: We sought to describe perfusion dyssynchrony analysis specifically to exploit the high temporal resolution of stress perfusion CMR. This novel approach detects differences in the temporal distribution of the wash-in of contrast agent across the left ventricular wall. METHODS AND RESULTS:

  8. Assessment of automatic quantification of myocardial perfusion and left ventricular function derived from ECG gated myocardial SPECT with {sup 99m}Tc-tetrofosmin in ischemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Mitsunori; Habara, Hirokazu; Tatsuno, Hironari; Fukuda, Hiroshi; Hamada, Noriko; Kazatani, Yukio [Ehime Prefectural Central Hospital (Japan)

    1999-09-01

    Non-invasive assessment of ischemic heart disease (IHD) requires information of both myocardial perfusion and left ventricular (LV) function. Recently, automatic quantification of ECG-gated myocardial scintigraphy with {sup 99m}Tc-tetrofosmin (QGS) can provide both of them. QGS, coronary angiograms (CAG) and left venticulograms (LVG) were performed in 83 patients with severe IHD in same period. Significant stenosis of coronary artery in CAG were assessed by QGS. The sensitivity, specificity and accuracy of significant stenosis by QGS was excellent (85%, 93% and 88%). The LV end-distolic and end-systolic volumes (EDV and ESV), LV ejection fraction (EF) and regional LV wall motion determined by QGS were compared to LVG. There was a good correlation between the values obtained from QGS and LVG (EDV: r=0.86, ESV: r=0.94, EF: r=0.84, p<0.0001), but QGS tended to underestimate EDV and EF. High complete agreement of regional LV wall motion was gained with 427 (74.0%) out of total 581 segments. In conclusion, QGS data was considered to be useful for assessment of determine significant stenosis and LV function in severe IHD. (author)

  9. Effect of beta-blockade on low-dose dobutamine-induced changes in left ventricular function in healthy volunteers: assessment by gated SPET myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Everaert, H.; Vanhove, C.; Franken, P.R. [Division of Nuclear Medicine, University Hospital, Free University of Brussels (AZ VUB), Brussels (Belgium)

    2000-04-01

    Viability studies are often performed in patients receiving beta-blocking agents. However, the intake of beta-blocking agents could influence the identification of viable myocardium when low-dose dobutamine is used to demonstrate inotropic reserve. The aim of this study was to quantify the effect of beta-blockade on global and regional left ventricular function in healthy volunteers using low-dose dobutamine gated single-photon emission tomographic (SPET) myocardial perfusion scintigraphy. Ten subjects were studied once ''on'' and once ''off'' beta-blocker therapy (metoprolol succinate, 100 mg day{sup -1}). On each occasion four consecutive gated SPET acquisitions (of 7 min duration) were recorded after injection of 925 MBq technetium-99m tetrofosmin on a triple-headed camera equipped with focussing (Cardiofocal) collimators. Acquisitions were made at rest (baseline 1 and 2) and 5 min after the beginning of the infusion of 5 and 10 {mu}g kg{sup -1} min{sup -1} dobutamine. Wall thickening (WT) was quantified using a method based on circumferential profile analysis. Left ventricular ejection fraction (LVEF) was obtained using the Cedars-Sinai algorithm. Blood pressure (BP) and heart rate (HR) were recorded at the end of each acquisition. At baseline LVEF, WT and systolic BP values under beta-blockade were not significantly different from those obtained in the non-beta-blocked state. The mean HR and diastolic BP at baseline were lower under beta-blockade. Dobutamine administration (at 5 and 10 {mu}g kg{sup -1} min{sup -1}) induced a significant increase in WT, LVEF and systolic BP in all subjects both on and off beta-blockade. The increases in WT, LVEF and systolic BP in the beta-blocked state were less pronounced but not significantly different. HR increased significantly at 10 {mu}g kg{sup -1} min{sup -1} dobutamine without beta-blocker administration, while no increase in HR was observed in the beta-blocked state. Beta

  10. Severe perioperative bleeding in renal cell carcinoma after elective pericardiocentesis associated left ventricular puncture: case report

    Directory of Open Access Journals (Sweden)

    Javier Lasala

    2016-07-01

    Full Text Available Resumen En los Estados Unidos se estimó que, durante el 2015, unos 61 560 pacientes serían diagnosticados con cáncer renal y que 14 080 morirían por esta enfermedad. Presentamos el caso de un paciente con carcinoma de células renales y trombo tumoral de vena cava inferior que sufrió una hemorragia perioperatoria grave y coagulopatía después de una esternotomía de emergencia. También abordamos aspectos relevantes del cuidado anestésico perioperatorio incluyendo consideraciones y manejo de coagulopatía, falla renal y hepática en un paciente oncológico. El caso es un hombre de 49 años que fue llevado a embolización tumoral guiada por radiología, nefrectomía radical izquierda y trombectomía de vena cava inferior. En el período postoperatorio desarrolló sepsis, falla orgánica múltiple y efusión pericárdica que requirió pericardiocentesis. Durante la pericardiocentesis sufrió perforación iatrogénica de ventrículo izquierdo que necesitó esternotomía de emergencia y reparación del ventrículo izquierdo. Los pacientes con cáncer son a menudo un reto para el equipo de cirugía y anestesia, y el cuidado de emergencia requiere un abordaje integral y organizado. El uso de factor recombinante VIIa NovoSeven puede ayudar en el manejo de la hemorragia severa perioperatoria después de cirugía cardiotorácica en pacientes oncológicos, pero se deben hacer estudios posteriores para confirmarlo.

  11. A randomized, controlled, double-blind crossover study on the effects of 1-L infusions of 6% hydroxyethyl starch suspended in 0.9% saline (voluven) and a balanced solution (Plasma Volume Redibag) on blood volume, renal blood flow velocity, and renal cortical tissue perfusion in healthy volunteers.

    Science.gov (United States)

    Chowdhury, Abeed H; Cox, Eleanor F; Francis, Susan T; Lobo, Dileep N

    2014-05-01

    We compared the effects of intravenous administration of 6% hydroxyethyl starch (maize-derived) in 0.9% saline (Voluven; Fresenius Kabi, Runcorn, United Kingdom) and a "balanced" preparation of 6% hydroxyethyl starch (potato-derived) [Plasma Volume Redibag (PVR); Baxter Healthcare, Thetford, United Kingdom] on renal blood flow velocity and renal cortical tissue perfusion in humans using magnetic resonance imaging. Hyperchloremia resulting from 0.9% saline infusion may adversely affect renal hemodynamics when compared with balanced crystalloids. This phenomenon has not been studied with colloids. Twelve healthy adult male subjects received 1-L intravenous infusions of Voluven or PVR over 30 minutes in a randomized, double-blind manner, with crossover studies 7 to 10 days later. Magnetic resonance imaging proceeded for 60 minutes after commencement of infusion to measure renal artery blood flow velocity and renal cortical perfusion. Blood was sampled, and weight was recorded at 0, 30, 60, 120, 180, and 240 minutes. Mean peak serum chloride concentrations were 108 and 106 mmol/L, respectively, after Voluven and PVR infusion (P = 0.032). Changes in blood volume (P = 0.867), strong ion difference (P = 0.219), and mean renal artery flow velocity (P = 0.319) were similar. However, there was a significant increase in mean renal cortical tissue perfusion after PVR when compared with Voluven (P = 0.033). There was no difference in urinary neutrophil gelatinase-associated liopcalin to creatinine ratios after the infusion (P = 0.164). There was no difference in the blood volume-expanding properties of the 2 preparations of 6% hydroxyethyl starch. The balanced starch produced an increase in renal cortical tissue perfusion, a phenomenon not seen with starch in 0.9% saline.

  12. A Case of Atrial Tachycardia Circulating around a Left Atrial Roof Scar with Diabetes Mellitus and Renal Failure on Hemodialysis

    Directory of Open Access Journals (Sweden)

    Naoko Hijioka

    2016-01-01

    Full Text Available Introduction. Little is known about the effects of volume change by hemodialysis (HD and mechanical stress caused by an anatomical structure being in contact with the left atrium on the progression of atrial remodeling. We experienced a case of atrial tachycardia (AT in a patient who had left atrial (LA scarring at the LA roof and a low-voltage area with slow conduction around the LA scar as components of AT circuit. Here, we present the conceivable hypothesis of the LA scar and the low-voltage area formation. Our concept can be useful in developing a strategy for ablation in a patient with chronic renal failure (CRF on HD. Case Report. A 65-year-old man with CRF on HD was referred for AT ablation. Three-dimensional electroanatomical mapping revealed that the AT conducted around an LA scar in a counterclockwise fashion. There was a slow conduction area at the superior side of the LA scar, where the AT was terminated during the ablation. Computed tomography indicated a close relationship between the LA and the anatomical structures (ascending aorta and pulmonary artery. Conclusion. Volume change by HD and close contact of anatomical structures to the LA can promote atrial remodeling, resulting in AT occurrence.

  13. Complex left profunda femoris vein to renal vein bypass for the management of progressive chronic iliofemoral occlusion.

    Science.gov (United States)

    Anaya-Ayala, Javier E; Adams, Matthew K; Telich-Tarriba, Jose E; Dresser, Kelly L; Ismail, Nyla; Peden, Eric K

    2013-01-01

    Chronic occlusions of the inferior vena cava (IVC) and iliofemoral veins are long-term sequelae of deep venous thrombosis (DVT) that can lead to postthrombotic syndrome (PTS). Patients may present with a wide spectrum of signs and symptoms, ranging from mild discomfort and swelling to severe venous hypertension and ulcerations. We report a 68-year-old man who had a history of left lower extremity DVT after a laminectomy and who developed PTS with nonhealing ulcers. The patient underwent a cross-pubic femorofemoral venous bypass that failed to improve his clinical status. After unsuccessful endovascular attempts for recanalization of the iliofemoral segment, a profunda femoris to IVC bypass was performed. The symptoms recurred 2 years later. Venography revealed restenosis at the caval anastomosis that did not resolve by endovascular means. A surgical revision was performed, and given the quality of the IVC, a jump bypass was created to the left renal vein. The swelling improved and the ulcers healed completely. Twenty-eight months after the complex reconstructions, he remains ulcer-free with mild edema controlled with stockings. Venous reconstructions remain a viable option for patients with symptomatic and recalcitrant nonmalignant obstruction of the large veins. Copyright © 2013 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  14. Left ventricular function in response to dipyridamole stress: head-to-head comparison between {sup 82}Rubidium PET and {sup 99m}Tc-sestamibi SPECT ECG-gated myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giorgi, Maria Clementina; Meneghetti, Jose Claudio; Soares, Jose; Izaki, Marisa; Falcao, Andrea; Imada, Rodrigo; Chalela, William; Oliveira, Marco Antonio de; Nomura, Cesar [Department of Radiology and Nuclear Medicine and Molecular Imaging Service - Heart Institute of the University of Sao Paulo Medical School, Sao Paulo (Brazil); Verberne, Hein J. [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, P.O. Box 22700, Amsterdam (Netherlands)

    2017-05-15

    Myocardial perfusion imaging (MPI) with {sup 99m}Tc-sestamibi (sestamibi) SPECT and rubidium-82 ({sup 82}Rb) PET both allow for combined assessment of perfusion and left ventricular (LV) function. We sought to compare parameters of LV function obtained with both methods using a single dipyridamole stress dose. A group of 221 consecutive patients (65.2 ± 10.4 years, 52.9% male) underwent consecutive sestamibi and {sup 82}Rb MPI after a single dipyridamole stress dose. Sestamibi and {sup 82}Rb summed rest (SRS), stress (SSS) and difference (SDS) scores, and LV end-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were compared. Bland-Altman analysis showed that with increasing ESV and EDV the difference between the two perfusion tracers increased both at rest and post-stress. The mean difference in EDV and ESV between the two perfusion tracers at rest could both be independently explained by the {sup 82}Rb SDS and the sestamibi SRS. The combined models explained approximately 30% of the variation in these volumes between the two perfusion tracers (R{sup 2} = 0.261, p = 0.005; R{sup 2} = 0.296, p < 0.001, for EDV and ESV respectively). However, the mean difference in LVEF between sestamibi and {sup 82}Rb showed no significant trend post-stress (R{sup 2} = 0.001, p = 0.70) and only a modest linear increase with increasing LVEF values at rest (R{sup 2} = 0.032, p = 0.009). Differences in left ventricular volumes between sestamibi and {sup 82}Rb MPI increase with increasing volumes. However, these differences did only marginally affect LVEF between sestamibi and {sup 82}Rb. In clinical practice these results should be taken into account when comparing functional derived parameters between sestamibi and {sup 82}Rb MPI. (orig.)

  15. Successful Dual Kidney Transplantation After Hypothermic Oxygenated Perfusion of Discarded Human Kidneys

    Science.gov (United States)

    Ravaioli, Matteo; De Pace, Vanessa; Comai, Giorgia; Busutti, Marco; Gaudio, Massimo Del; Amaduzzi, Annalisa; Cucchetti, Alessandro; Siniscalchi, Antonio; La Manna, Gaetano; D’Errico, Antonietta A.D.; Pinna, Antonio Daniele

    2017-01-01

    Patient: Female, 58 Final Diagnosis: Nephroangiosclerosis Symptoms: Renal failure Medication: — Clinical Procedure: Resuscitation of grafts by hypothermic oxygenated perfusion Specialty: Transplantology Objective: Challenging differential diagnosis Background: The recovery of discarded human kidneys has increased in recent years and impels to use of unconventional organ preservation strategies that improve graft function. We report the first case of human kidneys histologically discarded and transplanted after hypothermic oxygenated perfusion (HOPE). Case Report: Marginal kidneys from a 78-year-old woman with brain death were declined by Italian transplant centers due to biopsy score (right kidney: 6; left kidney: 7). We recovered and preserved both kidneys through HOPE and we revaluated their use for transplantation by means of perfusion parameters. The right kidney was perfused for 1 h 20 min and the left kidney for 2 h 30 min. During organ perfusion, the renal flow increased progressively. We observed an increase of 34% for the left kidney (median flow 52 ml/min) and 50% for the right kidney (median flow 24 ml/min). Both kidneys had low perfusate’s lactate levels. We used perfusion parameters as important determinants of the organ discard. Based on our previous organ perfusion experience, the increase of renal flow and the low level of lactate following 1 h of HOPE lead us to declare both kidneys as appropriate for dual kidney transplantation (DKT). No complications were reported during the transplant and in the post-transplant hospital stay. The recipient had immediate graft function and serum creatinine value of 0.95 mg/dL at 3 months post-transplant. Conclusions: HOPE provides added information in the organ selection process and may improve graft quality of marginal kidneys. PMID:28928357

  16. Late unıon of the renal veıns wıth the ınterposed left renal artery

    OpenAIRE

    Çavdar, Safiye; Şehirli, Ümit; Malcic-Gürbüz, Jasna; Gümüşçü, Burak; Akalın, Aytül

    2003-01-01

    The complicated embryological development of the renal vein shows extensive variability in its anatomy. In this study, the rare bilateral late union of the renal veins with the interposed renal artery was observed during dissection for educational purposes. Its significance in different clinical conditions has been discussed.

  17. The value of MR perfusion weighted imaging in normal and abnormal kidneys

    International Nuclear Information System (INIS)

    Shi Hao; Ding Hongyu; Duan Ruiping; Sun Yongping; Xing Yiyong

    2008-01-01

    Objective: To explore the characteristics and the clinical application of MR perfusion weighted imaging (PWI) in the normal kidneys and the renal diseases. Methods: Thirty-one subjects including 9 cases without urinary diseases, 14 cases with renal carcinoma, 6 cases with renal cyst and 2 cases with renal tuberculosis who had been examined with T 1 WI, T 2 WI and PWI were analyzed retrospectively. All the data were processed by a workstation to obtain time-signal intensity curves, color perfusion maps and relative perfusion value. The relative renal blood volume (RBV), relative renal blood flow (RBF), mean transition time (MTY) and the time to peak (TTP) in the normal renal cortex and medulla and the renal lesions were calculated. Comparisons between the right and the left normal kidneys, and between the cortex and the medulla of the normal kidneys were performed using t test, and comparisons between the normal and the abnormal kidneys were performed using q test. Results: Relative RBV and relative RBF of the cortex were 1.33±0.08 and 1.44±0.09 respectively, and for medulla were 0.58± 0.05 and 0.78±0.13 respectively (t=9.2241 and 5.0336, P 0.05). The values of relative RBF of the renal carcinoma (1.35±0.34) were significantly higher than that of the normal tissues (1.02±0.06) (q=3.0882, P< 0.01). Conclusion: PWI is able to demonstrate the hemodynamic change of the normal renal tissues and the renal lesions, and it maybe an ideal method for showing the functional changes of the kidney and for differentiating the renal diseases. (authors)

  18. Effect of mobilization of bone marrow stem cells by granulocyte colony stimulating factor on clinical symptoms, left ventricular perfusion and function in patients with severe chronic ischemic heart disease

    DEFF Research Database (Denmark)

    Wang, Yongzhong; Tägil, Kristina; Ripa, Rasmus S.

    2005-01-01

    . Myocardial perfusion was unchanged at adenosine stress single photon emission computerized tomography (SPECT) or magnetic resonance images (MRI). Left ventricular ejection fraction decreased from 57% to 52% (p... with echocardiography. CONCLUSIONS: Treatment by G-CSF improved symptoms but not signs of myocardial ischemia in patients with severe IHD. The effects seemed related to mobilization of stem cells. An adverse effect on ejection fraction could not be excluded...

  19. Evaluation of Renal Blood Flow in Chronic Kidney Disease Using Arterial Spin Labeling Perfusion Magnetic Resonance Imaging.

    Science.gov (United States)

    Li, Lu-Ping; Tan, Huan; Thacker, Jon M; Li, Wei; Zhou, Ying; Kohn, Orly; Sprague, Stuart M; Prasad, Pottumarthi V

    2017-01-01

    Chronic kidney disease (CKD) is known to be associated with reduced renal blood flow. However, data to-date in humans is limited. In this study, non-invasive arterial spin labeling (ASL) MRI data was acquired in 33 patients with diabetes and stage-3 CKD, and 30 healthy controls. A significantly lower renal blood flow both in cortex (108.4±36.4 vs . 207.3±41.8; pblood flow were correlated with eGFR, and cortical blood flow was found to be confounded by age and BMI. However, in a subset of subjects that were matched for age and BMI (n=6), the differences between CKD and control subjects remained significant both in cortex (107.4±42.8 vs . 187.51±20.44; p=0.002) and medulla (15.43±8.43 vs . 39.18±11.13; p=0.002). A threshold value to separate healthy and CKD was estimated to be Cor_BF=142.9 and Med_BF=24.1. These results support the use of ASL in the evaluation of renal blood flow in patients with moderate level of CKD. Whether these measurements can identify subjects at risk of progressive CKD requires further longitudinal follow-up.

  20. Computer assisted nuclear assessment of renal perfusion in a two kidney, one clip canine model of Goldblatt hypertension

    International Nuclear Information System (INIS)

    Clarke, H.St.C. Jr.

    1984-01-01

    This study was designed to evaluate ninety-second and fifteen-minute Technetium-DTPA (/sup 99m/Tc-DTPA) time-activity curves in acute unilateral renal artery stenosis (RAS). The /sup 99m/Tc-DTPA studies were compared to angiograms, PAH clearances (C/sup PAH/), and thirty-minute 131 I-Hippuran renograms in eight dogs prior to and after RAS. Renal artery stenosis resulted in a reduction of the renal blood flow ranging from 32% to 68%, as measured by electromagnetic flow probe and C/sub PAH/. The mean arterial pressure increased 21 mmHg. Changes in the ninety-second /sup 99m/Tc-DTPA curve were identified by eight computer isolated curve parameters. The fifteen minute /sup 99m/Tc-DTPA curves were interpreted according to the same criteria used in analyzing the 131 I-Hippuran renograms, specifically the time to maximum activity, ratios of peak activity, and time to return to baseline activity. Both the ninety-second and the fifteen-minute /sup 99m/Tc-DTPA studies were superior to the 131 I-Hippuran renogram in assessing RAS. It is concluded that (1) /sup 99m/Tc-DTPA studies are superior to 131 I-Hippuran renograms for detecting unilateral experimental RAS, and (2) /sup 99m/Tc-DTPA may be the radioisotope of choice for detection and follow-up of RAS

  1. The trend distribution ratio, a new tool for evaluating renal perfusion scintigraphy with 99mTc-DTPA following renal transplantation

    International Nuclear Information System (INIS)

    Kittner, C.; Esther, G.; Finck, W.; Bast, R.; Templin, R.; Nizze, H.; Brockmoeller, S.

    1993-01-01

    We developed a new quantitative concept in dynamic renal transplant imaging, the Trend Distribution Ratio, and tested its diagnostic usefulness in 137 examinations. This ratio is an expression of the distribution of blood flow velocity in different areas of the kidney. With regard to the differential diagnosis between acute tubular necrosis and the various forms of rejection we arrived at a sensitivity of 0.83 and a specificity of 0.54. A differentiation between the various histological types of rejection has not yet been possible. (orig.) [de

  2. Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT. Can we use the same reference database?

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Yamaguchi, Hitoshi; Tsujimura, Eiichiro; Nishimura, Tsunehiko [Osaka Univ., Suita (Japan). Graduate School of Medicine

    2000-04-01

    The purpose of this study was to compare left ventricular (LV) volume and ejection fraction (LVEF) measurements obtained with electrocardiographic gated single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (GS-MPI) with those obtained with gated SPECT cardiac blood-pool imaging (GS-pool). Fifteen patients underwent GS-MPI with technetium-99m tetrofosmin and GS-pool with technetium-99m-erythrocyte, within a mean interval of 8{+-}3 days. Eight patients had suspected dilated cardiomyopathy and seven patients had angiographically significant coronary artery disease. End-diastolic volume (EDV), end-systolic volume (ESV) and LVEF measurements were estimated from GS-MPI images by means of Cedars-Sinai automatic quantitative program and from GS-pool images by the threshold technique. Mean differences between GS-MPI and GS-pool in EDV, ESV and LVEF measurements were -2.8{+-}10.5 ml [95% confidence interval (CI): -8.6{+-}3.0 ml], 2.6{+-}7.3 ml (CI: -1.4-6.6 ml) and -2.3{+-}5.1% (CI: -5.1-0.6%), respectively. No significant difference in the mean differences from 0 was found for EDV, ESV or LVEF measurements. Bland-Altman plots revealed no trend over the measured LV volumes and LVEF. For all parameters, regression lines approximated lines of identity. The excellent agreement between GS-MPI and GS-pool measurements suggests that, for estimation of LV volumes and LVEF, these two techniques may be used interchangeably and measurements by one method can serve as a reference for the other. (author)

  3. Case report: Varicosity of the communicating vein between the left renal vein and the left ascending lumbar vein mimicking a renal artery aneurysm: Report of an unusual site of varicose veins and a novel hypothesis to explain its association with abdominal pain

    Directory of Open Access Journals (Sweden)

    Sandeep G Jakhere

    2011-01-01

    Full Text Available A communicating vein between the left renal vein and the left ascending lumbar vein has only rarely been reported in the imaging literature. There are very few reports of varicosity of this communicating vein. Nonetheless, awareness about this communicating vein is of utmost importance for surgeons performing aortoiliac surgeries and nephrectomies as it may pose technical difficulties during surgery or cause life-threatening retroperitoneal hemorrhage. Varicosity of this venous channel may be mistaken for paraaortic lymphadenopathy, adrenal pseudo-mass, or renal artery aneurysm. We report a case of a patient with varicosity of this communicating vein, which mimicked a left renal artery aneurysm. A novel hypothesis is also proposed to explain the relationship with abdominal pain.

  4. Incidental Anatomic Finding of Celiacomesenteric Trunk Associated with ‘Nutcracker Phenomenon,’ or Compression of the Left Renal Vein

    Science.gov (United States)

    Peterson, Joshua; Hage, Anthony N.; Diljak, Stephan; Long, Benjamin D.; Marcusa, Daniel P.; Brzezinski, David W.; Eliason, Jonathan

    2017-01-01

    Patient: Female, 91 Final Diagnosis: Nutcracker syndrome • celiacomesenteric trunk Symptoms: Dyspepsia • dysphagia Medication: — Clinical Procedure: — Specialty: Surgery Objective: Congenital defects/diseases Background: Celiacomesenteric trunk (CMT) is a very rare anatomic finding in which the celiac artery and the superior mesenteric artery (SMA) originate from the abdominal aorta through a common trunk. Clinical associations with CMT include arterial aneurysm, thrombosis, and celiac artery compression. However, an association between CMT and abdominal venous congestion caused by left renal vein compression, or ‘nutcracker phenomenon,’ has not been previously reported. Case Report: A 91-year-old woman, who died from a cerebrovascular accident (CVA), underwent a cadaveric examination at our medical school. On examination of the abdomen, there was an incidental finding of CMT. The arterial and venous diameters were measured, and vascular histopathology was undertaken. The vascular anatomy was consistent with CMT type 1-b. Nutcracker phenomenon (NCP) (left renal vein compression) was seen anatomically as dilatation and engorgement of the left renal vein, relative to the right renal vein (10.77±0.13 mm vs. 4.49±0.56 mm, respectively), and dilatation and engorgement of the left ovarian vein, relative to the right ovarian vein (4.37±0.15 mm vs. 1.06±0.09 mm, respectively) with left ovarian varicocele. The aortoceliac angle (ACA) and the aortomesenteric angle (AMA) approached zero degrees. Conclusions: We have described a rare anatomic finding of CMT that created an acute AMA and NCP. Awareness of this rare association between CMT and NCP by clinicians, vascular surgeons, and radiologists may be of value in the future evaluation and surgical management of patients who present clinically with ‘nutcracker syndrome.’ PMID:29242494

  5. Left kidney angiomyolipoma, spreading to the renal vein, inferior vena cava and involving the heart. Report of one case

    OpenAIRE

    INNOCENTI C, FRANCO; ALARCÓN C, EMILIO; ARIAS O, ESTEBAN; STOCKINS L, ALECK; SÁNCHEZ U, ROBERTO; MADARIAGA B, JAIME; TORRES-QUEVEDO Q, RODRIGO; CABRERA E, FELIPE; DÍAZ J, RAMÓN

    2008-01-01

    El angiomiolipoma renal es un tumor benigno mesenquimático. Constituyen sólo del 2 al 6% de los tumores renales. Existen alrededor de 12 casos reportados con invasión a las venas renales y la cava inferior. En menos de 5, hay extensión de trombo tumoral hasta aurícula derecha. Objetivo: Presentar el caso clínico, manejo y evolución de una paciente con un angiomiolipoma renal con extensión tumoral a vena renal y cava inferior y que compromete la cavidad auricular derecha casi en su totalidad. ...

  6. Clinical values of left ventricular mechanical dyssynchrony assessment by gated myocardial perfusion SPECT in patients with acute myocardial infarction and multivessel disease

    International Nuclear Information System (INIS)

    Cho, Sang-Geon; Park, Ki Seong; Kim, Jahae; Kim, Jong Sang; Song, Ho-Chun; Jabin, Zeenat; Kang, Sae-Ryung; Kwon, Seong Young; Jeong, Geum-Cheol; Song, Minchul; Min, Jung-Joon; Bom, Hee-Seung; Cho, Jae Yeong; Kim, Hyun Kuk

    2017-01-01

    The aim of this study was to evaluate the prognostic value of additional evaluation of left ventricular mechanical dyssynchrony (LVMD) by gated myocardial perfusion single-photon emission computed tomography (GMPS) in patients with acute myocardial infarction (MI) and multivessel disease. One hundred and nine acute MI patients with >50 % stenosis in at least one non-culprit artery who underwent GMPS within 2 weeks were enrolled. All patients underwent successful revascularization of the culprit arteries. Those with previous MI, atrial fibrillation, or frequent ventricular premature complexes, cardiac devices, significant patient motion, or procedure-related events were excluded. Phase standard deviation (PSD) and phase histogram bandwidth (PBW) were measured for assessment of LVMD. Patients were followed up for a median of 26 months after index MI, for composite major adverse cardiac events (MACE), which consisted with all-cause death, unplanned hospitalization due to heart failure and severe ventricular arrhythmias (sustained ventricular tachycardia or ventricular fibrillation). Independent predictors of MACE were evaluated. MACE occurred in 22 patients (20 %). Stress PSD (53.3 ± 17.3 vs. 35.3 ± 18.9 ; p <0.001), stress PBW (147.6 ± 54.6 vs. 96.8 ± 59.2 ; p = 0.001) and resting PBW (126.8 ± 37.5 vs. 96.6 ± 48.9 ; p = 0.001) were significantly higher in patients with MACE compared to those without. Multivariate analysis revealed that stress PSD ≥45.5 and stress PBW ≥126.0 were predictive of MACE, as well as suboptimal non-culprit artery revascularization (SNR) and renin-angiotensin system (RAS) blockade medication. Higher stress PSD and stress PBW were associated with poorer prognosis both in patients with and without SNR, and those with RAS blockade medication, but not in those without RAS blockade medication. LVMD measured by GMPS showed added prognostic value in acute MI with multivessel disease. GMPS could serve as a comprehensive evaluation imaging

  7. Clinical values of left ventricular mechanical dyssynchrony assessment by gated myocardial perfusion SPECT in patients with acute myocardial infarction and multivessel disease

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang-Geon; Park, Ki Seong; Kim, Jahae; Kim, Jong Sang; Song, Ho-Chun [Chonnam National University Hospital, Department of Nuclear Medicine, Gwang-ju (Korea, Republic of); Jabin, Zeenat; Kang, Sae-Ryung; Kwon, Seong Young; Jeong, Geum-Cheol; Song, Minchul; Min, Jung-Joon; Bom, Hee-Seung [Chonnam National University Hwasun Hospital, Department of Nuclear Medicine, Hwasun-gun, Jeonnam (Korea, Republic of); Cho, Jae Yeong; Kim, Hyun Kuk [Chonnam National University Hospital, Department of Cardiology, Gwang-ju (Korea, Republic of)

    2017-02-15

    The aim of this study was to evaluate the prognostic value of additional evaluation of left ventricular mechanical dyssynchrony (LVMD) by gated myocardial perfusion single-photon emission computed tomography (GMPS) in patients with acute myocardial infarction (MI) and multivessel disease. One hundred and nine acute MI patients with >50 % stenosis in at least one non-culprit artery who underwent GMPS within 2 weeks were enrolled. All patients underwent successful revascularization of the culprit arteries. Those with previous MI, atrial fibrillation, or frequent ventricular premature complexes, cardiac devices, significant patient motion, or procedure-related events were excluded. Phase standard deviation (PSD) and phase histogram bandwidth (PBW) were measured for assessment of LVMD. Patients were followed up for a median of 26 months after index MI, for composite major adverse cardiac events (MACE), which consisted with all-cause death, unplanned hospitalization due to heart failure and severe ventricular arrhythmias (sustained ventricular tachycardia or ventricular fibrillation). Independent predictors of MACE were evaluated. MACE occurred in 22 patients (20 %). Stress PSD (53.3 ± 17.3 vs. 35.3 ± 18.9 ; p <0.001), stress PBW (147.6 ± 54.6 vs. 96.8 ± 59.2 ; p = 0.001) and resting PBW (126.8 ± 37.5 vs. 96.6 ± 48.9 ; p = 0.001) were significantly higher in patients with MACE compared to those without. Multivariate analysis revealed that stress PSD ≥45.5 and stress PBW ≥126.0 were predictive of MACE, as well as suboptimal non-culprit artery revascularization (SNR) and renin-angiotensin system (RAS) blockade medication. Higher stress PSD and stress PBW were associated with poorer prognosis both in patients with and without SNR, and those with RAS blockade medication, but not in those without RAS blockade medication. LVMD measured by GMPS showed added prognostic value in acute MI with multivessel disease. GMPS could serve as a comprehensive evaluation imaging

  8. Renal hemodynamics and oxygenation in transient renal artery occluded rats evaluated with iron-oxide particles and oxygenation-sensitive imaging

    International Nuclear Information System (INIS)

    Pedersen, Michael; Aarhus Univ.; Univ. Victor Segalen Bordeaux 2; Laustsen, Christoffer; Perot, Vincent; Grenier, Nicolas; Basseau, Fabrice; Moonen, Chrit

    2010-01-01

    Mild or severe renal arterial occlusion is a phenomenon occasionally observed in daily clinical practice, potentially leading to renal ischemia and a general impairment of renal function. Secondly, closing the blood flow to the kidneys can also occur during kidney transplantation procedures. However, the exact physiological effects of these conditions on renal blood perfusion as well as the renal oxygen handling are poorly understood. The objectives of this study were therefore to measure the lateral changes of renal blood perfusion in rats subjected to transient unilateral arterial occlusion (RAS), and in addition, to measure the consequences on the intrarenal oxygenation. Experimental studies were performed using sixteen adolescent rats. The left renal artery was exposed through a flank incision and acute RAS for 45 min was achieved by placing a ligature around the renal artery. MRI was performed 3 days after the surgical procedure, where a blood oxygenation sensitive sequence (BOLD MRI) was performed, followed by a perfusion-weighted imaging sequence using a single bolus of the iron-oxide nanoparticle Sinerem. The renal oxygenation of blood was indirectly measured by the BOLD-parameter R2 * , and perfusion measures include relative renal blood flow, relative renal blood volume and mean transit time. Histopathologic changes through the outer stripe of the outer medulla showing typical histopathologic findings of ischemia. This study demonstrated that rats with transient renal arterial stenosis (for 45 min) showed a reduction in intrarenal oxygenation and intrarenal blood flow three days after the surgical procedure. A decreased R2 * was measured within the ipsilateral medulla in parallel with a decreased medullary blood flow, is probably related to a lower reabsorption load within the ipsilateral kidney. MRI may therefore be a promising tool in long-term evaluation of RAS. (orig.)

  9. Renal hemodynamics and oxygenation in transient renal artery occluded rats evaluated with iron-oxide particles and oxygenation-sensitive imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Michael [Aarhus Univ. Hospital (Denmark). MR Research Centre; Aarhus Univ. (Denmark). Inst. of Experimental Clinical Medicine; Univ. Victor Segalen Bordeaux 2 (France). Lab. Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231; Laustsen, Christoffer [Aarhus Univ. Hospital (Denmark). MR Research Centre; Perot, Vincent; Grenier, Nicolas [Hopital Pellegrin, CHU Bordeaux (France). Service d' Imagerie Diagnostique et Therapeutique de l' Adulte; Basseau, Fabrice; Moonen, Chrit [Univ. Victor Segalen Bordeaux 2 (France). Lab. Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231

    2010-07-01

    Mild or severe renal arterial occlusion is a phenomenon occasionally observed in daily clinical practice, potentially leading to renal ischemia and a general impairment of renal function. Secondly, closing the blood flow to the kidneys can also occur during kidney transplantation procedures. However, the exact physiological effects of these conditions on renal blood perfusion as well as the renal oxygen handling are poorly understood. The objectives of this study were therefore to measure the lateral changes of renal blood perfusion in rats subjected to transient unilateral arterial occlusion (RAS), and in addition, to measure the consequences on the intrarenal oxygenation. Experimental studies were performed using sixteen adolescent rats. The left renal artery was exposed through a flank incision and acute RAS for 45 min was achieved by placing a ligature around the renal artery. MRI was performed 3 days after the surgical procedure, where a blood oxygenation sensitive sequence (BOLD MRI) was performed, followed by a perfusion-weighted imaging sequence using a single bolus of the iron-oxide nanoparticle Sinerem. The renal oxygenation of blood was indirectly measured by the BOLD-parameter R2{sup *}, and perfusion measures include relative renal blood flow, relative renal blood volume and mean transit time. Histopathologic changes through the outer stripe of the outer medulla showing typical histopathologic findings of ischemia. This study demonstrated that rats with transient renal arterial stenosis (for 45 min) showed a reduction in intrarenal oxygenation and intrarenal blood flow three days after the surgical procedure. A decreased R2{sup *} was measured within the ipsilateral medulla in parallel with a decreased medullary blood flow, is probably related to a lower reabsorption load within the ipsilateral kidney. MRI may therefore be a promising tool in long-term evaluation of RAS. (orig.)

  10. Association of renal biochemical parameters with left ventricular diastolic dysfunction in a community-based elderly population in China: a cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Jingmin Zhou

    Full Text Available BACKGROUND: Relationship of left ventricular diastolic dysfunction (LVDD with parameters that could provide more information than hemodynamic renal indexes has not been clarified. We aimed to explore the association of comprehensive renal parameters with LVDD in a community-based elderly population. METHODS: 1,166 community residents (aged ≥ 65 years, 694 females participating in the Shanghai Heart Health Study with complete data of renal parameters were investigated. Echocardiography was used to evaluate diastolic function with conventional and tissue Doppler imaging techniques. Serum urea, creatinine, urea-to-creatinine ratio, estimated glomerular filtration rate (eGFR and urinary albumin-to-creatinine ratio (UACR were analyzed on their associations with LVDD. RESULTS: The prevalence of LVDD increased in proportion to increasing serum urea, urea-to-creatinine ratio and UACR. These three renal parameters were found negatively correlated to peak early (E to late (A diastolic velocities ratio (E/A, and positively to left atrial volume index; UACR also positively correlated with E to peak early (E' diastolic mitral annular velocity ratio (E/E'. Serum urea, urea-to-creatinine ratio and UACR correlated with LVDD in logistic univariate regression analysis, and urea-to-creatinine ratio remained independently correlated to LVDD [Odds ratio (OR 2.82, 95% confidence interval (CI 1.34-5.95] after adjustment. Serum urea (OR 1.18, 95%CI 1.03-1.34, creatinine (OR 6.53, 95%CI 1.70- -25.02, eGFR (OR 0.22, 95%CI 0.07-0.65 and UACR (OR 2.15, 95%CI 1.42-3.24 were revealed independent correlates of advanced (moderate and severe LVDD. CONCLUSIONS: Biochemical parameters of renal function were closely linked with LVDD. This finding described new cardio-renal relationship in the elderly population.

  11. Renal Resistance Trend During Hypothermic Machine Perfusion Is More Predictive of Postoperative Outcome Than Biopsy Score: Preliminary Experience in 35 Consecutive Kidney Transplantations.

    Science.gov (United States)

    Bissolati, Massimiliano; Gazzetta, Paolo Giovanni; Caldara, Rossana; Guarneri, Giovanni; Adamenko, Olga; Giannone, Fabio; Mazza, Michele; Maggi, Giulia; Tomanin, Deborah; Rosati, Riccardo; Secchi, Antonio; Socci, Carlo

    2018-03-30

    Hypothermic machine perfusion (HPM) grants a better postoperative outcome in transplantation of organs procured from extended criteria donors (ECDs) and donors after cardiac death (DCD). So far, the only available parameter for outcome prediction concerning those organs is pretransplant biopsy score. The aim of this study is to evaluate whether renal resistance (RR) trend during HPM may be used as a predictive marker for post-transplantation outcome. From December 2015 to present, HMP has been systematically applied to all organs from ECDs and DCD. All grafts underwent pretransplantation biopsy evaluation using Karpinski's histological score. Only organs that reached RR value ≤1.0 within 3 hours of perfusion were transplanted. Single kidney transplantation (SKT) or double kidney transplantation (DKT) were performed according to biopsy score results. Sixty-five HMPs were performed (58 from ECDs and 7 from DCD/ECMO donors). Fifteen kidneys were insufficiently reconditioned (RR > 1) and were therefore discarded. Forty-nine kidneys were transplanted, divided between 21 SKT and 14 DKT. Overall primary nonfunction (PNF) and delayed graft function (DGF) rate were 2.9 and 17.1%, respectively. DGF were more common in kidneys from DCD (67 vs. 7%; P = 0.004). Biopsy score did not correlate with PNF/DGF rate (P = 0.870) and postoperative creatinine trend (P = 0.796). Recipients of kidneys that reached RR ≤ 1.0 within 1 hour of HMP had a lower PNF/DGF rate (11 vs. 44%; P = 0.033) and faster serum creatinine decrease (POD10 creatinine: 1.79 mg/dL vs. 4.33 mg/dL; P = 0.019). RR trend is more predictive of post-transplantation outcome than biopsy score. Hence, RR trend should be taken into account in the pretransplantation evaluation of the organs. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Comparison of myocardial fatty acid metabolism with left ventricular function and perfusion in cardiomyopathies. By 123I-BMIPP SPECT and 99mTc-tetrofosmin electrocardiographically gated SPECT

    International Nuclear Information System (INIS)

    Zhao, Chunlei; Shuke, Noriyuki; Okizaki, Atsutaka

    2003-01-01

    The objective of this study was to investigate myocardial fatty acid metabolism and its relationship with left ventricular (LV) function and perfusion in hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (DCM). Thirty-nine patients with cardiomyopathies (58±14 y), comprising 15 DCM and 24 HCM, and 9 age-matched healthy controls were studied with 123 I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and 99m Tc-tetrofosmin (TF) electrocardiographically gated SPECT. As parameters of myocardial fatty acid metabolism, the heart-to-mediastinum ratio (H/M) and global washout of BMIPP were calculated from early and delayed planar images, while regional BMIPP uptake and washout were calculated from SPECT. In TF study, the H/M (H/M-TF) and LV ejection fraction (LVEF) were calculated as global parameters of perfusion and function, while regional TF uptake and wall thickening index were calculated as regional parameters of perfusion and function using the Quantitative Gated SPECT software. The differences in the parameters and the correlations between the parameters from the 2 studies were investigated by one-way ANOVA and multiple linear regression analysis. BMIPP uptake was decreased (p 0.05), but showed a significant correlation with H/M-TF (p 0.05) but had a significant correlation with regional perfusion (p<0.0001) in DCM. In HCM, regional BMIPP parameters showed significant multiple linear correlations with both regional function (p<0.005) and perfusion (p<0.0001). According to the partial correlation coefficients, delayed regional BMIPP uptake was the most significant factor for predicting regional function in HCM, while early regional BMIPP uptake was the only or the most significant factor for predicting regional perfusion in DCM and HCM, respectively. In DCM, BMIPP uptake and washout could not reflect LV function. In HCM, regional delayed BMIPP uptake might be useful for evaluating regional function. In DCM and HCM, early BMIPP uptake might be

  13. Nuclear cardiology. I - Radionuclide angiographic assessment of left ventricular contraction: uses, limitations and future directions. II - The role of myocardial perfusion imaging using thallium-201 in diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Bodenheimer, M.M.; Banka, V.S.; Helfant, R.H.; Pennsylvania, University, Philadelphia, PA)

    1980-01-01

    The current status of radionuclide angiography is reviewed. First pass and gated equilibrium methods for determining left ventricular contraction are compared. Some clinical applications of radionuclide angiography are then examined, including the detection of discrete versus diffuse asynergy and the assessment of myocardial infarction. The second part of this work reviews the uses and limitations of thallium-201 perfusion imaging in the diagnosis of the acute and chronic manifestations of coronary heart disease. Theoretical and technical considerations of thallium-201 imaging are reviewed along with the clinical implications of the technique

  14. Cerebral and Renal Oxygen Saturation Are Not Compromised in the Presence of Retrograde Blood Flow in either the Ascending or Descending Aorta in Term or Near-Term Infants with Left-Sided Obstructive Lesions

    NARCIS (Netherlands)

    van der Laan, Michelle E.; Mebius, Mirthe J.; Roofthooft, Marcus T. R.; Bos, Arend F.; Berger, Rolf M. F.; Kooi, Elisabeth M. W.

    2017-01-01

    Background: In infants with left-sided obstructive lesions (LSOL), the presence of retrograde blood flow in either the ascending or descending aorta may lead to diminished cerebral and renal blood flow, respectively. Objectives: Our aim was to compare cerebral and renal tissue oxygen saturation

  15. Large Renal Artery Aneurysm Treated with Guglielmi Detachable Coils: Procedural and 4-Year Follow-up Results

    International Nuclear Information System (INIS)

    Damascelli, Bruno; Bartorelli, Antonio L.; Ticha, Vladimira; Trabattoni, Daniela; Lanocita, Rodolfo

    2008-01-01

    A large aneurysm of the left renal artery was found incidentally during abdominal ultrasound in a 39-year-old woman with no medical or family history of cardiovascular disease. Vascular pathology with a dysplastic appearance was confirmed by magnetic resonance angiography and the patient was offered transcatheter embolization. Since the position and size of the neck of the aneurysm could not be determined at angiography, detachable platinum coils were used for occlusion. The procedure was performed without complications. During a 4-year follow-up no alterations of renal function, recanalization of the aneurysm, or perfusion defects in the rest of the left renal circulation were noted.

  16. Ligation of the left renal vein in epm1-wistar rats: functional and morphologic alterations in the kidneys, testes and suprarenal glands

    Directory of Open Access Journals (Sweden)

    José Carlos Costa Baptista-Silva

    Full Text Available OBJECTIVE: The ligation of the left renal vein (LLVR in man is a contraversial procedure in view of the risks of lesion to the renal parenchyma. With the objective of studying the morphologic and functional alterations caused by these lesions, we conducted experimental research with rats. MATERIAL AND METHODS: 64 male adult EPM1-WISTAR rats were used, divided into 8 groups - 4 for LLRV and four for control. Each LLRV group and corresponding control group were sacrificed progressively on the 7th, 15th, 30th and 60th day after the initial surgery. RESULTS: We found morphofunctional alterations only in animals that underwent LLRV in the four periods of sacrifice.The proteinuria creatinine in serum, testosterone in serum and serum corticosterone in serum showed practically no alteration in relation to the normal values for rats. Statistically significant severe histological lesions were found in the kidneys and testes of the LLRV groups. Lesions in the suprarenal glands were also present in these groups, but no sufficient to demonstrate statistical significance CONCLUSION: Based on these results we can conclude that the ligation of the left renal vein is a procedure of high risk in these animals.

  17. Association between left ventricular dysfunction, anemia, and chronic renal failure. Analysis of the Heart Failure Prevalence and Predictors in Turkey (HAPPY) cohort.

    Science.gov (United States)

    Kepez, A; Mutlu, B; Degertekin, M; Erol, C

    2015-06-01

    Anemia and chronic renal failure (CRF) are frequent comorbidities in patients with heart failure (HF), and they have been reported to be associated with increased mortality and hospitalization rates. HF, anemia, and CRF have been reported to interact with each other forming a vicious cycle termed cardio-renal-anemia syndrome. The aim of the present study was to evaluate the association of HF, anemia, and CRF using data from the large-scale"Heart Failure Prevalence and Predictors in Turkey (HAPPY)" study. Among the HAPPY cohort, 3,369 subjects who had either left ventricular dysfunction (LVD) or normal left ventricular function on echocardiography or normal serum NT-proBNP levels were included in this analysis. The prevalence of anemia and CRF was significantly higher in patients with LVD compared with subjects with normal ventricular function (20.7 % vs. 4.0 % and 19.0 % vs. 3.7 %, respectively; p renal-anemia syndrome and the necessity of treating these comorbidities in patients with HF.

  18. Instrument-independent flux units for laser Doppler perfusion monitoring assessed in a multi-device study on the renal cortex

    NARCIS (Netherlands)

    Petoukhova, AL; Steenbergen, W; Morales, F; Graaff, R; de Jong, ED; Elstrodt, JM; de Mul, FFM; Rakhorst, G

    To investigate the feasibility of instrument-independent perfusion units for laser Doppler flowmetry, a comparison was performed of two commercial fiberoptic laser Doppler perfusion monitors measuring the same flux situation for two different types of probes. In vivo measurements were performed on

  19. Instrument-independent flux units for laser Doppler perfusion monitoring assessed in a multi-device study on the renal cortex

    NARCIS (Netherlands)

    Petoukhova, Anna; Steenbergen, Wiendelt; Morales, F.; Graaff, R.; de Jong, Ed; Elstrodt, J.M.; de Mul, F.F.M.; Rakhorst, G.

    2003-01-01

    To investigate the feasibility of instrument-independent perfusion units for laser Doppler flowmetry, a comparison was performed of two commercial fiberoptic laser Doppler perfusion monitors measuring the same flux situation for two different types of probes. In vivo measurements were performed on

  20. Limb ischemia, an alarm signal to a thromboembolic cascade - renal infarction and nephrectomy followed by surgical suppression of the left atrial appendage.

    Science.gov (United States)

    Caraşca, Cosmin; Borda, Angela; Incze, Alexandru; Caraşca, Emilian; Frigy, Attila; Suciu, HoraŢiu

    2016-01-01

    We present the case of a 55-year-old male with mild hypertension and brief episodes of paroxysmal self-limiting atrial fibrillation (AF) since 2010. Despite a small cardioembolic risk score, CHA2DS2-Vasc=1 (Congestive heart failure, Hypertension, Age=75, Diabetes melitus, prior Stroke), the patient is effectively anticoagulated using acenocumarol. In December 2014, he showed signs of plantar transitory ischemia, for which he did not address the doctor. In early January 2015, he urgently presented at the hospital with left renal pain, caused by a renal infarction, diagnosed by computed tomography (CT) angiography. Left nephrectomy was performed with pathological confirmation. He was discharged with effective anticoagulation treatment. Within the next two weeks, he suffered a transitory ischemic event and a stroke, associated with right sided hemiparesis. On admission, AF was found and converted to sinus rhythm with effective anticoagulation - international normalized ratio (INR) of 2.12. Transthoracic echocardiography detected no pathological findings. Transesophageal echocardiography showed an expended left atrial appendage (LAA) with a slow blood flow (0.2 m÷s) and spontaneous echocontrast. Considering these clinical circumstances, surgical LAA suppression was decided on as a last therapeutic resort. Postoperative evolution was favorable; the patient is still free of ischemic events, one year post-intervention. Some morphological and hemodynamic characteristics of LAA may add additional thromboembolic risk factors, not included in scores. Removing them by surgical LAA suppression may decrease the risk of cardioembolic events. Intraoperative presence of thrombus makes it an indisputable proof.

  1. Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated {sup 82}rubidium myocardial perfusion PET

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Tracy L.Y.; Merrill, Jennifer; Bengel, Frank M. [Johns Hopkins University, Department of Radiology and Radiological Sciences, Division of Nuclear Medicine, Baltimore, MD (United States); Volokh, Lana [GE Healthcare, Haifa (Israel)

    2008-02-15

    Myocardial perfusion imaging with {sup 82}Rb PET allows for ECG-gated studies to be obtained early after radiotracer injection, capturing ventricular function close to peak pharmacologic action of dipyridamole. This is different from gated SPECT and may potentially provide additional diagnostic information. We sought to identify potential correlates of the PET-derived ejection fraction response to vasodilator stress. One hundred ten consecutive patients undergoing {sup 82}Rb PET myocardial perfusion imaging during evaluation for coronary artery disease were included. Using a GE Discovery STRx PET-CT scanner, ECG-gated images (eight bins) were obtained at rest and 4 min after dipyridamole infusion, 90 s after infusion of 1,480-2,220 MBq of {sup 82}Rb. Summed rest, stress, and difference scores (SRS, SSS, and SDS) were determined using a five-point scoring system and 20-segment model. Ejection fraction was calculated using automated QGS software. Significant reversibility (SDS {>=} 4) was found in 23 patients (21%). Mean LVEF in all patients was 47 {+-} 13% at rest and 53 {+-} 13% during dipyridamole. LVEF increased in 89 patients, and decreased in 17 patients during vasodilation. The change in LVEF was inversely correlated with SDS (r = -0.26; p = 0.007). Additionally, it was inversely correlated with resting LVEF (r = -0.20; p = 0.03) and SSS (r = -0.25; p = 0.009). No significant correlations were observed with SRS, heart rate, blood pressure, age, hypertension, hypercholesterolemia, or pretest likelihood of disease. At multivariate regression analysis, SDS was an independent predictor of the change in LVEF. Gated {sup 82}Rb PET during pharmacologic stress allows for assessment of the functional response to vasodilation. The magnitude of LVEF increase is determined by stress perfusion/reversible perfusion defects. Functional response to hyperemia may thus be incorporated in future evaluations of diagnostic and prognostic algorithms based on {sup 82}Rb PET. (orig.)

  2. Cirurgia do arco aórtico com perfusão cerebral bilateral pelo isolamento do tronco braquiocefálico e da artéria carótida esquerda Aortic arch surgery with bilateral cerebral perfusion by isolation of brachiocephalic trunk and left carotid artery

    Directory of Open Access Journals (Sweden)

    Valdo José Carreira

    2008-03-01

    Full Text Available OBJETIVO: Estudar os resultados da técnica descrita por Carreira et al. com utilização de perfusão cerebral seletiva bilateral (PCSAB pelo isolamento do tronco braquiocefálico e artéria carótida esquerda. MÉTODOS: Quinze pacientes foram operados consecutivamente entre de junho de 2005 e setembro de 2007. Os dados foram analisados por programa informatizado Epi Info e significância estatística com p0,05. CONCLUSÃO: A técnica de PCSAB é reprodutível e apresenta resultados semelhantes aos da literatura mundial. A excelente evolução neurológica e o fácil controle de sangramentos nas linhas de sutura podem ter contribuído com os resultados obtidos.OBJECTIVE: To evaluate the results of a technique described by Carreira et al. using bilateral antegrade selective cerebral perfusion by isolating the brachiocephalic trunk and the left carotid artery. METHODS: Fifteen patients were operated between June 2005 and September 2007. Data analysis were performed using Epi Info and statistical significance was set at p0.05. CONCLUSION: The technique of bilateral selective cerebral perfusion described by Carreira et al. can be performed by others and presents similar results to the international literature. The excellent neurological outcome and easy bleeding control on surgical sutures lines are the major advantages of this new procedure.

  3. Power doppler ultrasound findings of renal infarct after experimental renal artery occlusion: comparison with spiral CT

    International Nuclear Information System (INIS)

    Jung, Seung Eun; Shinn, Kyung Sub; Kim, Hak Hee; Mun, Seok Hwan; Lee, Young Joon; Lee, Bae Young; Choi, Byung Gil; Lee, Jae Mun; Lee, Hee Jeong

    1999-01-01

    To evaluate the efficacy of power Doppler ultrasonography (PDUS) in depicting renal infarction in rabbits during experimental renal segmental arterial occlusion, and to compare the results with those of CT scanning. In 28 rabbits weighing 2.5 4kg, the segmental renal artery was occluded through the left main renal artery by embolization with Ivalon (Nycomed, Paris, France). Power Doppler ultrasonography and spiral CT scanning were performed before and at 2, 5, 8, 15, and 24 hours, and 3 and 7 days after occlusion of the segmental renal artery. The location of infarcted areas and collaterals, as seen on PDUS and CT scans, was evaluated by two radiologists. In all cases, as seen on power Doppler ultrasonography, infarcted areas-when compared with normal parenchyma, clearly demonstrated wedge-shaped perfusion defects in the kidney. The location of the lesion closely corresponded to the location seen during CT scanning. After renal arterial occlusion, transiently congested capsular arteries, which were named 'capsular sign', were seen in 63% of rabbits in the two and five-hour groups. No significant cortical rim sign was demonstrated on power Doppler ultrasonography, though it was noted on spiral CT at 15 and 24 hours, and 3 and 7 days after renal arterial occlusion. Power Doppler ultrasonography was useful for the diagnosis of renal infarction. Congested capsular artery seen in the early stage of renal infarction might be a characteristic finding of this condition, as seen on power Doppler ultrasonography

  4. Renal Function and Outcomes With Use of Left Ventricular Assist Device Implantation and Inotropes in End-Stage Heart Failure: A Retrospective Single Center Study.

    Science.gov (United States)

    Verma, Sean; Bassily, Emmanuel; Leighton, Shane; Mhaskar, Rahul; Sunjic, Igor; Martin, Angel; Rihana, Nancy; Jarmi, Tambi; Bassil, Claude

    2017-07-01

    Left ventricular assist device (LVAD) and inotrope therapy serve as a bridge to transplant (BTT) or as destination therapy in patients who are not heart transplant candidates. End-stage heart failure patients often have impaired renal function, and renal outcomes after LVAD therapy versus inotrope therapy have not been evaluated. In this study, 169 patients with continuous flow LVAD therapy and 20 patients with continuous intravenous inotrope therapy were analyzed. The two groups were evaluated at baseline and at 3 and 6 months after LVAD or inotrope therapy was started. The incidence of acute kidney injury (AKI), need for renal replacement therapy (RRT), BTT rate, and mortality for 6 months following LVAD or inotrope therapy were studied. Results between the groups were compared using Mann-Whitney U test and Chi-square with continuity correction or Fischer's exact at the significance level of 0.05. Mean glomerular filtration rate (GFR) was not statistically different between the two groups, with P = 0.471, 0.429, and 0.847 at baseline, 3 and 6 months, respectively. The incidence of AKI, RRT, and BTT was not statistically different. Mortality was less in the inotrope group (P < 0.001). Intravenous inotrope therapy in end-stage heart failure patients is non-inferior for mortality, incidence of AKI, need for RRT, and renal function for 6-month follow-up when compared to LVAD therapy. Further studies are needed to compare the effectiveness of inotropes versus LVAD implantation on renal function and outcomes over a longer time period.

  5. BILATERAL DUPLICATION OF RENAL ARTERIES

    OpenAIRE

    Prajkta A Thete; Mehera Bhoir; M.V.Ambiye

    2014-01-01

    Routine dissection of a male cadaver revealed the presence of bilateral double renal arteries. On the right side the accessory renal artery originated from the abdominal aorta just above the main renal artery. On the left side the accessory renal artery originated from the abdominal aorta about 1 cm above the main renal artery. Knowledge of the variations of renal vascular anatomy has importance in exploration and treatment of renal trauma, renal transplantation, renal artery embolization, su...

  6. Regional changes in renal cortical glucose, lactate and urea during acute unilateral ureteral obstruction

    DEFF Research Database (Denmark)

    Krarup, Peter-Martin; Stolle, Lars B; Rawashdeh, Yazan F

    2007-01-01

    . Furthermore, we investigated regional variations in renal interstitial fluid (RIF) glucose, lactate and urea during acute UUO. MATERIAL AND METHODS: Eight anesthetized pigs were used. Microdialysis probes were inserted in the upper, middle and lower thirds of the left renal cortex and perfused with Ringer...... third. RIF lactate did not change. Interstitial urea increased in all regions of the kidney, but most markedly in the upper and lower poles. CONCLUSIONS: Microdialysis is of potential value for assessing the renal interstitial milieu under different pathophysiological conditions. Ureteral obstruction...

  7. [Portal perfusion with right gastroepiploic vein flow in liver transplant].

    Science.gov (United States)

    Mendoza-Sánchez, Federico; Javier-Haro, Francisco; Mendoza-Medina, Diego Federico; González-Ojeda, Alejandro; Cortés-Lares, José Antonio; Fuentes-Orozco, Clotilde

    Liver transplantation in patients with liver cirrhosis, portal vein thrombosis, and cavernous transformation of the portal vein, is a complex procedure with high possibility of liver graft dysfunction. It is performed in 2-19% of all liver transplants, and has a significantly high mortality rate in the post-operative period. Other procedures to maintain portal perfusion have been described, however there are no reports of liver graft perfusion using right gastroepiploic vein. A 20 year-old female diagnosed with cryptogenic cirrhosis, with a Child-Pugh score of 7 points (class "B"), and MELD score of 14 points, with thrombosis and cavernous transformation of the portal vein, severe portal hypertension, splenomegaly, a history of upper gastrointestinal bleeding due to oesophageal varices, and left renal agenesis. The preoperative evaluation for liver transplantation was completed, and the right gastroepiploic vein of 1-cm diameter was observed draining to the infrahepatic inferior vena cava and right suprarenal vein. An orthotopic liver transplantation was performed from a non-living donor (deceased on January 30, 2005) using the Piggy-Back technique. Portal vein perfusion was maintained using the right gastroepiploic vein, and the outcome was satisfactory. The patient was discharged 13 days after surgery. Liver transplantation was performed satisfactorily, obtaining an acceptable outcome. In this case, the portal perfusion had adequate blood flow through the right gastroepiploic vein. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  8. Gated SPECT evaluation of myocardial perfusion defects and left ventricular function in chronic atrial fibrillation (CAF) patients - a prevalence study between a General Hospital (GH) and a referral Cardiology Hospital (CH)

    International Nuclear Information System (INIS)

    Rocha, G.; Guimaraes, M.; Marroni, B.; Zagoury, E.; Sprinz, C.; Andrea, S.; Louzada, A.; Ludwig, R.; Graef, C.

    2002-01-01

    Aims: to evaluate myocardial perfusion defects (MPD) prevalence and left ventricular function in CAF patients from a distinct referral basis (a GH and CH populations). Materials and Methods: a retrospective cross-sectional survey including 171 CAF (43 from GH and 128 from CH) and 5415 control patients (2222 from GH and 3193 from CH) submitted to rest/stress myocardial perfusion gated SPECT with Tc99m-MIBI. The following items were collected from CAF patients: the percentage of patients with MPD, the type (fixed, reversible or mixed) and number of segments with MPD and left ventricular ejection fraction (LVEF). The control patients percentage of MPD, their type and number were also collected. Results: CAF from GH and CH were not significantly different in the number of patients with MPD, mean number of segments affected, and LVEF. In GH patients, the CAF group had more segments with MPD (2,4x1,6 p<0,01) and lower LVEF (37%x52% p<0,01) than control group. CAF patients from CH also showed lower LVEF (40%x58% p<0,01) and more fixed MPD (40%x18% p<0,01) than their control group population. Conclusion: our data showed similar prevalence of MPD and reduced LVEF values between CAF patients from a GH and referral CH. The CAF group from CH seemed to have more fixed MPD perhaps reflecting more severe coronary artery disease population or referral bias. The data appears to support the evaluation of myocardial ischemia as a part of CAF possible etiologies. Caution is advised in LVEF evaluation of CAF patients due to increased variability of R-R interval

  9. Contralateral thalamic hypoperfusion on brain perfusion SPECT

    International Nuclear Information System (INIS)

    Lee, Seok Mo; Bae, Sang Kyun; Yoo, Kyung Moo; Yum, Ha Yong

    2000-01-01

    Brain perfusion single photon emission computed tomography (SPECT) is useful for the localization of cerebrovascular lesion and sometimes reveals more definite lesion than radiologic imaging modality such as CT or MRI does. The purpose of this study was to evaluate the diagnostic usefulness of brain perfusion SPECT in patients with hemisensory impairment. Thirteen consecutive patients (M:F= 8:5, mean age = 48) who has hemisensory impairment were included. Brain perfusion SPECT was performed after intravenous injection of 1110 MBq of Tc-99m ECD. The images were obtained using a dual-head gamma camera with ultra-high resolution collimator. Semiquantitative analysis was performed after placing multiple ROIs on cerebral cortex, basal ganglia, thalamus and cerebellum. There were 10 patients with left hemisensory impairment and 3 patients with right-sided symptom. Only 2 patients revealed abnormal signal change in the thalamus on MRI. But brain perfusion SPECT showed decreased perfusion in the thalamus in 9 patients. Six patients among 10 patients with left hemisensory impairment revealed decreased perfusion in the contralateral thalamus on brain SPECT. The other 4 patients revealed no abnormality. Two patients among 3 patients with right hemisensory impairment also showed decreased perfusion in the contralateral thalamus on brain SPECT. One patients with right hemisensory impairment showed ipsilateral perfusion decrease. Two patients who had follow-up brain perfusion SEPCT after treatment revealed normalization of perfusion in the thalamus. Brain perfusion SPECT might be a useful tool in diagnosing patients with hemisensory impairment

  10. Bilateral renal artery variation

    OpenAIRE

    Üçerler, Hülya; Üzüm, Yusuf; İkiz, Z. Aslı Aktan

    2014-01-01

    Each kidney is supplied by a single renal artery, although renal artery variations are common. Variations of the renal arteryhave become important with the increasing number of renal transplantations. Numerous studies describe variations in renalartery anatomy. Especially the left renal artery is among the most critical arterial variations, because it is the referred side forresecting the donor kidney. During routine dissection in a formalin fixed male cadaver, we have found a bilateral renal...

  11. Selective hypertrophy of the lobus caudatus as a novel approach enabling extended right hepatectomy in the presence of a non-perfused left lateral liver lobe.

    Science.gov (United States)

    Atanasov, Georgi; Schmelzle, Moritz; Thelen, Armin; Wiltberger, Georg; Hau, Hans-Michael; Krenzien, Felix; Petersen, Tim-Ole; Moche, Michael; Jonas, Sven

    2014-08-01

    Portal vein embolization (PVE) is a well-established technique to enhance functional hepatic reserves of segments II and III before curative extended right hepatectomy for tumors of the right liver lobe. However, an adequate hepatopetal flow of the left lateral portal vein branches is required for a sufficient PVE-associated hypertrophy. Here, we report a 65-year old patient suffering from a locally advanced intrahepatic cholangiocarcinoma in the right liver lobe and segment IV. A curative extended right hepatectomy after preoperative PVE of liver segments IV-VIII was initially impossible because of partial thrombosis of the left lateral portal vein branches resulting in an ischemic-type atrophy of segments II and III. However, due to a massive hypertrophy of the caudate lobe following PVE of liver segments IV-VIII, subsequent extended right hepatectomy with intraoperative thrombectomy of segments II and III was made possible. To our knowledge this is the first case in which an extended right hepatectomy for a liver malignancy, in the presence of atrophic left lateral section, was made possible by a massive PVE-associated hypertrophy of the caudate lobe.

  12. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block; Perfusao miocardica de estresse com dipiridamol por tomografia computadorizada em pacientes com bloqueio de ramo esquerdo

    Energy Technology Data Exchange (ETDEWEB)

    Cabeda, Estevan Vieira; Rochitte, Carlos Eduardo; Nomura, Cesar Higa; Parga, Jose Rodrigues; Avila, Luiz Francisco Rodrigues; Falcao, Andrea Maria Gomes; Soares Junior, Jose [Instituto do Coracao (InCor), Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil)

    2015-12-15

    Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution's ethics committee. Results: The patients' mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB. (author)

  13. Effect of fluid loading on left ventricular volume and stroke volume variability in patients with end-stage renal disease: a pilot study

    Science.gov (United States)

    Kanda, Hirotsugu; Hirasaki, Yuji; Iida, Takafumi; Kanao-Kanda, Megumi; Toyama, Yuki; Kunisawa, Takayuki; Iwasaki, Hiroshi

    2015-01-01

    Purpose The aim of this study was to investigate fluid loading-induced changes in left ventricular end-diastolic volume (LVEDV) and stroke volume variability (SVV) in patients with end-stage renal disease (ESRD) using real-time three-dimensional transesophageal echocardiography and the Vigileo-FloTrac system. Patients and methods After obtaining ethics committee approval and informed consent, 28 patients undergoing peripheral vascular procedures were studied. Fourteen patients with ESRD on hemodialysis (HD) were assigned to the HD group and 14 patients without ESRD were assigned to the control group. Institutional standardized general anesthesia was provided in both groups. SVV was measured using the Vigileo-FloTrac system. Simultaneously, a full-volume three-dimensional transesophageal echocardiography dataset was acquired to measure LVEDV, left ventricular end-systolic volume, and left ventricular ejection fraction. Measurements were obtained before and after loading 500 mL hydroxyethyl starch over 30 minutes in both groups. Results In the control group, intravenous colloid infusion was associated with a significant decrease in SVV (13.8%±2.6% to 6.5%±2.6%, P<0.001) and a significant increase in LVEDV (83.6±23.4 mL to 96.1±28.8 mL, P<0.001). While SVV significantly decreased after infusion in the HD group (16.2%±6.0% to 6.2%±2.8%, P<0.001), there was no significant change in LVEDV. Conclusion Our preliminary data suggest that fluid responsiveness can be assessed not by LVEDV but also by SVV due to underlying cardiovascular pathophysiology in patients with ESRD. PMID:26527879

  14. Evaluation of Renal Function in Children by Tc-99m DTPA Scintigraphy

    Directory of Open Access Journals (Sweden)

    Sevin Ayaz

    2016-09-01

    Full Text Available Aim: Dynamic renal scintigraphy can demonstrate both structural and functional renal pathologies. Our aim was to evaluate renal functions in children by technetium-99m diethylenetriaminepentaacetic acid (Tc-99m DTPA dynamic renal scintigraphy, and todetermine the frequency of scintigraphically detectable atrophic kidneys. Material and Method: Dynamic renal scintigraphy studies of 17 children (12 males, five females with urinary system complaints, having a mean age of 6.15 ± 4.41 years, were included in this retrospective study. Images were obtained with a dual-head gamma camera after intravenous (IV injection of Tc-99m DTPA. Results: The functions of 34 kidneys were evaluated. Decreased perfusion of the left and right kidneys was detected in 35.3% (n=6/17 and 11.8% (n=2/17 of cases, respectively. Prolongation in Tmax of the left and right kidneys was shown in 52.9% (n=9/17 and 29.4% (n=5/17 of the cases, respectively. Glomerular filtration rate of the left and right kidneys was normal in 64.7% (n=11/17 and 88.2% (n=15/17 of cases, respectively. Delayed excretion of the left and right kidneys wasdetected in 29.4% (n=5/17 and 11.8% (n=2/17 of cases, respectively. Stasis of urine in the left and right kidneys which responded to IV diuretics wasdemonstrated in 58.8% (n=10/17 and 70.6% (n=12/17 of cases, respectively. Dynamic renal scintigraphy findings in favour of left and right renal atrophy were obtained in 17.6% (n=3/17 and 5.9% (n=1/17 of cases, respectively. Discussion: Dynamic renal scintigraphy with Tc-99m DTPA was found to be useful in the evaluation of renal functions of children and in determining the frequency of atrophic kidneys.

  15. Implications of normal exercise electrocardiographic results in patients with angiographically documented coronary artery disease. Correlation with left ventricular function and myocardial perfusion

    International Nuclear Information System (INIS)

    Hakki, A.H.; DePace, N.L.; Colby, J.; Iskandrian, A.S.

    1983-01-01

    The purpose of this study was to examine the incidence and implications of false-negative exercise electrocardiographic results among 216 consecutive patients with angiographically documented coronary artery disease (50 percent diameter narrowing or greater of one or more vessels). Exercise electrocardiography gave negative (false-negative) results in 23 patients and positive (true-positive) results in 102 patients, and were nondiagnostic in the rest. Exercise thallium-201 imaging was performed in 88 patients. The extent of coronary artery disease was quantitated by a scoring system that takes into consideration the degree and site of narrowing in the major vessels and their branches. The exercise heart rate was higher in patients with false-negative than in patients with true-positive exercise electrocardiographic results (161 +/- 18 versus 133 +/- 24 beats per minute, mean +/- SD; p less than 0.0001). Q-wave infarction was present in two patients (9 percent) with false-negative and 20 patients (20 percent) with true-positive exercise electrocardiographic results; left ventricular asynergy at rest was observed in 13 patients (57 percent) with false-negative and in 74 patients (74 percent) with true-positive results. Patients with false-negative results had less extensive coronary disease than did patients with true-positive results (score 5.8 +/- 3.6 versus 9.2 +/- 5.0; p . 0.0025). Angina during exercise was less frequent in patients with false-negative results (p less than 0.01). Abnormal exercise thallium-201 images were seen in 15 of 20 patients (75 percent) with false-negative results and in 56 of 68 patients (82 percent) with true-positive results

  16. Resección de un carcinoma renal izquierdo con extensión trombótica hacia la aurícula derecha Resection of a left renal carcinoma with thrombotic extension to right atrium

    Directory of Open Access Journals (Sweden)

    Alejandro Villar Inclán

    2010-09-01

    Full Text Available Se presenta el caso de un hombre de 59 años con diagnóstico de hipernefroma izquierdo y trombosis de la vena cava inferior con extensión hacia la aurícula derecha. Un equipo multidisciplinario realizó una nefrectomía radical izquierda, exposición de la vena cava inferior con técnica de piggyback, atriotomía derecha y cavotomía inferior para extracción del trombo, previo pinzamiento de la vena renal derecha y el hilio hepático. El tiempo quirúrgico total fue de 7 h 30 min. El procedimiento se realizó con anestesia general y un período mínimo de derivación cardiopulmonar. Se utilizó monitorización transoperatoria estandarizada de los parámetros vitales y además ecocardiografía transesofágica para la detección de la remoción completa del trombo y su extracción, así como posibles émbolos desprendidos. La evolución transoperatoria y posoperatoria fue satisfactoria. Se realiza una revisión de la literatura médica internacional sobre el tema y se ofrecen conclusiones.This is the male case aged 59 diagnosed with left hypernephroma and thrombosis of the inferior vena cava with extension to right atrium. A multidisciplinary staff performed a left radical nephrectomy, exposition of inferior vena cava using the piggyback technique, right atriotomy and inferior cavotomy for extension of thrombus and previous clamping of right renal vein and hepatic hilus. The total surgical time was of 7 hours and 30 minutes. The procedure was performed under general anesthesia and a minimal period of cardiopulmonary shunt. Standardized transoperative monitoring of vital parameters was used and also transesophageal echocardiography to detect the total removal of thrombus and its extraction, as well as the potential detached emboli. The transoperative and postoperative course was satisfactory. A review of the international medical literature on this subject was made offering conclusions.

  17. Characteristics of Brain Perfusion in Patients of Parkinson's Disease

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Park, Min Jung; Kim, Jae Woo; Kang, Young Kang

    2008-01-01

    It was well known that cerebral blood perfusion is normal or diffusely decreased in the majority of patients with Parkinson's disease (PD). Actually we interpreted brain perfusion SPECT images of PD patients in the clinical situation, we observed various cerebral perfusion patterns in patients with PD. So we performed brain perfusion SPECT to know the brain perfusion patterns of PD patients and the difference of perfusion patterns according to the sex and the age. Also we classified PD patients into small groups based on the brain perfusion pattern. Two hundred nineteen patients (M: 70, F: 149, mean age: 62.9±6.9 y/o) who were diagnosed as PD without dementia clinically and 55 patients (M: 15, F: 40, mean age: 61.4±9.2 y/o) as normal controls who had no past illness history were performed 99m Tc-HMPAO brain perfusion SPECT and neuropsychological test. At first, we compared all patients with PD and normal controls. Brain perfusion in left inferior frontal gyrus, left insula, left transverse temporal gyrus, left inferior parietal lobule, left superior parietal lobule, right precuneus, right caudate tail were lower in patients with PD than normal controls. Secondly, we compared male and female patients with PD and normal controls, respectively. Brain perfusion SPECT showed more decreased cerebral perfusion in left hemisphere than right side in both male and female patients compared to normal controls. And there was larger hypoperfusion area in female patients compared with male. Thirdly, we classified patients with PD and normal controls into 4 groups according to the age and compared brain perfusion respectively. In patient below fifties, brain perfusion in both occipitoparietal and left temporal lobe were lower in PD group. As the patients with PD grew older, hypoperfusion area were shown in both frontal, temporal and limbic lobes. Fourthly, We were able to divide patients into small groups based on cerebral perfusion pattern. There was normal cerebral blood

  18. Association of clearance of middle- and large-molecular-weight substance with arterial stiffness and left ventricular mass in children receiving renal replacement therapy.

    Science.gov (United States)

    Özdemir, Kadriye; Yilmaz, Ebru; Dincel, Nida; Bozabali, Sibel; Apaydin, Sukriye; Gun, Zubeyr H; Sozeri, Betul; Mir, Sevgi

    2017-12-01

    The prominent cause of mortality in children receiving dialysis treatment is cardiovascular diseases. Risk factors related to chronic renal disease, are effective in the development of cardiovascular diseases. The aim of study was to investigate cardiovascular system (CVS) involvement for functional and structural alterations in children receiving dialysis, and display any association between cardiovascular morbidity and uremic toxins. 20 dialysis patients and 20 healthy controls were included to the study. Clearance of small, middle and large molecular-weight uremic toxins was evaluated in blood samples collected 30 minutes before (D0) and 2 hour after dialysis (D2), and change value was calculated as D0-D2/D0. Cardiovascular involvement was determined by comparing arterial stiffness, carotid intima-media thickness (CIMT) and Left Ventricular Mass Index (LVMI) with the control group. Four patients receiving hemodialysis and two patients in continuous ambulatory peritoneal dialysis (CAPD) group who have significant differences in all functional and structural parameters were detected. Four dialysis patients with detected cardiovascular disease have distinctively lower beta-2 microglobulin and homocysteine clearances compared to the patients with no CVS involvement. The clearance of middle and large molecular-weight substances should be closely monitored in children receiving dialysis.

  19. Stress-induced myocardial ischemia is associated with early post-stress left ventricular mechanical dyssynchrony as assessed by phase analysis of {sup 201}Tl gated SPECT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Cheng; Shen, Thau-Yun [Show Chwan Memorial Hospital, Department of Cardiology, Changhua (China); Chang, Ming-Che [Changhua Christian Hospital, Department of Nuclear Medicine, Changhua (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China); Chen, Wan-Chen [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Kao, Chia-Hung [China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China); Chen, Ji [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States)

    2012-12-15

    In {sup 201}Tl SPECT myocardial perfusion imaging (MPI) data are acquired shortly after the stress injection to assess early post-stress left ventricle (LV) function. The purpose of this study was to use {sup 201}Tl SPECT MPI to investigate whether stress-induced myocardial ischemia is associated with LV mechanical dyssynchrony. Enrolled in the study were 75 patients who were referred for dipyridamole stress and rest {sup 201}Tl gated SPECT MPI. The early post-stress scan was started 5 min after injection, and followed by the rest scan 4 h later. The patients were divided into three groups: ischemia group (N = 25, summed stress score, SSS, {>=}5, summed rest score, SRS, <5), infarct group (N = 16, SSS {>=}5, SRS {>=}5) and normal group (N = 34, SSS <5, SRS <5). LV dyssynchrony parameters were calculated by phase analysis, and compared between the stress and rest images. In the ischemia group, LV dyssynchrony was significantly larger during stress than during rest. On the contrary, LV dyssynchrony during stress was significantly smaller than during rest in the normal and infarct groups. LV dyssynchrony during rest was significantly larger in the infarct group than in the normal and ischemia groups. There were no significant differences in LV dyssynchrony during rest between the normal and ischemia groups. Stress-induced myocardial ischemia caused dyssynchronous contraction in the ischemic region, leading to a deterioration in LV synchrony. Normal myocardium had more synchronous contraction during stress. The different dyssynchrony pattern between ischemic and normal myocardium early post-stress may aid the diagnosis of coronary artery disease using {sup 201}Tl gated SPECT MPI. (orig.)

  20. Reversible ventilation and perfusion abnormalities in unilateral obstructed lung

    International Nuclear Information System (INIS)

    Ward, H.E.; Jones, R.L.; King, E.G.; Sproule, B.J.; Fortune, R.L.

    1982-01-01

    An intraluminal carcinoid tumor obstructing the left mainstem bronchus produced hypoxemia through alteration in ventilation/perfusion matching. Studies of regional lung function using 133-xenon (/sup 133/Xe) and a multiprobe computerized instrumentation system documented a reduction of perfusion to 22 percent and ventilation to 6 percent of the total. There was negligible washout of intravenously injected /sup 133/Xe from the left lung consistent with air trapping. Four days after left mainstem bronchial sleeve resection, perfusion, ventilation and washout of injected xenon had significantly improved and by four months postresection, all measurements were virtually normal, although complete restoration of perfusion in relation to ventilation was delayed. Regional lung function studied with a multiprobe system in this patient provided a clinical model for the study of ventilation and perfusion inter-relationships in large airway obstruction and demonstrated that a prolonged time may be required for return of perfusion to normal

  1. Cerebral and Renal Oxygen Saturation Are Not Compromised in the Presence of Retrograde Blood Flow in either the Ascending or Descending Aorta in Term or Near-Term Infants with Left-Sided Obstructive Lesions.

    Science.gov (United States)

    van der Laan, Michelle E; Mebius, Mirthe J; Roofthooft, Marcus T R; Bos, Arend F; Berger, Rolf M F; Kooi, Elisabeth M W

    2017-01-01

    In infants with left-sided obstructive lesions (LSOL), the presence of retrograde blood flow in either the ascending or descending aorta may lead to diminished cerebral and renal blood flow, respectively. Our aim was to compare cerebral and renal tissue oxygen saturation (rSO2) between infants with LSOL with antegrade and retrograde blood flow in the ascending aorta and with and without diastolic backflow in the descending aorta. Based on 2 echocardiograms, the study group was categorized according to the direction of blood flow in the ascending and descending aorta. We measured cerebral and renal rSO2 using near-infrared spectroscopy and calculated fractional tissue oxygen extraction (FTOE). Nineteen infants with LSOL, admitted to the NICU between 0 and 28 days after birth, were included. Infants with antegrade blood flow (n = 12) and infants with retrograde blood flow in the ascending aorta (n = 7) had similar cerebral rSO2 and FTOE during both echocardiograms. Only during the first echocardiogram, infants with retrograde blood flow in the ascending aorta had lower renal FTOE (0.14 vs. 0.32, p = 0.04) and tended to have higher renal rSO2 (80 vs. 65%, p = 0.09). The presence of diastolic backflow in the descending aorta was not associated with cerebral or renal rSO2 and FTOE during the first (n = 8) as well as the second echocardiogram (n = 10). Retrograde blood flow in the ascending aorta was not associated with cerebral oxygenation, while diastolic backflow in the descending aorta was not associated with renal oxygenation in infants with LSOL. © 2017 S. Karger AG, Basel.

  2. Regional myocardial perfusion of cardioplegic solutions

    International Nuclear Information System (INIS)

    Eugene, J.; Lyons, K.P.; Ott, R.A.; Gelezunas, V.L.; Chang, C.W.; Kowall, M.G.; Haiduc, N.J.

    1987-01-01

    We compared the regional myocardial perfusion of blood cardioplegic solution (BCP) and crystalloid cardioplegic solution (CCP) in 14 mongrel dogs. Cardiopulmonary bypass was established at 28 degrees C, and a hydraulic occluder was placed around the proximal left anterior descending (LAD) coronary artery. In group 1 (N = 7) collateral coronary arteries were ligated; in group 2 (N = 7) collateral coronary arteries were left in situ. After the aorta was clamped, BCP and CCP were alternately perfused at 200 ml/min. The occluder was inflated to produce moderate, severe, and critical LAD stenosis, and regional perfusion was measured by xenon-133 washout with the Silicon Avalanche Radiation Detector. BCP infusion produced a consistently higher aortic pressure, but CCP flow was better than BCP flow under all conditions, particularly without coronary collaterals. Regional myocardial perfusion of CCP is superior to BCP

  3. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Dowdle, S.C.; Human, D.G.; Mann, M.D. (Univ. of Cape Town (South Africa))

    1990-08-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis.

  4. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    International Nuclear Information System (INIS)

    Dowdle, S.C.; Human, D.G.; Mann, M.D.

    1990-01-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis

  5. Renal cell carcinoma in patient with crossed fused renal ectopia

    Directory of Open Access Journals (Sweden)

    Ozgur Cakmak

    2016-01-01

    Full Text Available Primary renal cell carcinomas have rarely been reported in patients with crossed fused renal ectopia. We presented a patient with right to left crossed fused kidney harbouring renal tumor. The most frequent tumor encountered in crossed fused renal ectopia is renal cell carcinoma. In this case, partial nephrectomy was performed which pave way to preservation of the uninvolved both renal units. Due to unpredictable anatomy, careful preoperative planning and meticulous delineation of renal vasculature is essential for preservation of the uninvolved renal units.

  6. Detectable perfusion changes in MAG3 studies

    International Nuclear Information System (INIS)

    Shuter, B.; Bernar, A.; Roach, P.

    1998-01-01

    Full text: The use of 120 MBq 99m Tc-MAG 3 instead of 600 MBq 99m Tc-DTPA in renal imaging has degraded the images obtained during the perfusion phase. An increase of the minimum detectable change (MDC) in blood flow (BF) would also be expected. In transplant patients, renal BF is an important factor in patient management and the MDC should be small to allow early detection of reduced perfusion. We determined the mean and coefficient of variation (CoV: standard deviation/mean) of three renal perfusion indices as a function of counts in the time-activity curves (TACs). Transplant patients were given a dose of about 300 MBq of 99m Tc-MAG3 and images acquired at 8 fps for 60s. TACs made up from 8, 4, 2 or I images per second allowed calculation of renal perfusion indices as if doses of 300, 150, 75 and 38 MBq had been administered. Perfusion indices based on area under the TACs up to the arterial peak (API), the maximum slopes of the TACs (SPI) and the maximum slope of renal TAC and height of arterial TAC (BPI) were calculated by our routine renal software package. As the administered dose decreased, the CoV rose for all indices, least for BPI and most for API. BPI CoV increased from ∼10% at 300 MBq to 20% at 75 MBq, but API CoV rose from 6% to 46%. Mean BPI was stable over the dose range, but mean API showed a systematic increase of about 50% over the 300 MBq result. We conclude that at 120 MBq the MDC (expressed as 2*CoV) in BF is 30-60%, whereas at 600 MBq it may be as low as 10%, allowing earlier confident detection of a change in BF. The BPI was the preferred perfusion index as its mean value changed little and it had the least CoV at lower activities. The data also imply that relative kidney perfusion in the one individual will be much less accurate with 120 MBq of MAG 3

  7. Pulmonary perfusion ''without ventilation''

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-12-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  8. Hypothermic Machine Perfusion of Kidney Grafts: Which Pressure is Preferred?

    NARCIS (Netherlands)

    Doorschodt, B. M.; Schreinemachers, M. C. J. M.; Behbahani, M.; Florquin, S.; Weis, J.; Staat, M.; Tolba, R. H.

    2011-01-01

    To assess the effect of the perfusion pressure (PP) during machine perfusion (MP) on the preservation quality of kidney grafts, we compared mean PPs of 25 and 30 mmHg using a porcine autotransplantation model. After assessment of the microcirculation, animals underwent left nephrectomy. Thereafter,

  9. Effect of preload reduction by hemodialysis on left atrial volume and echocardiographic Doppler parameters in patients with end-stage renal disease.

    Science.gov (United States)

    Barberato, Silvio H; Mantilla, Diego E V; Misocami, M Arcio; Gonçalves, Simone M; Bignelli, Alexandre T; Riella, Miguel C; Pecoits-Filho, Roberto

    2004-11-01

    Left atrial (LA) volume has been proposed as a less preload-dependent parameter of diastolic function than Doppler mitral inflow. We hypothesize that in the absence of mitral regurgitation and atrial fibrilation, LA enlargement could be a more practical (and relatively preload-independent) method for the evaluation of left ventricular diastolic function. The aim of the present study was to determine the effects of preload reduction by hemodialysis on LA volume.

  10. A case of reversible dilated cardiomyopathy after alpha-interferon therapy in a patient with renal cell carcinoma.

    Science.gov (United States)

    Kuwata, Akiko; Ohashi, Masuo; Sugiyama, Masaya; Ueda, Ryuzo; Dohi, Yasuaki

    2002-12-01

    A 47-year-old man with renal cell carcinoma underwent nephrectomy, and postoperative chemotherapy was performed with recombinant alpha-interferon. Five years later, he experienced dyspnea during physical exertion. An echocardiogram revealed dilatation and systolic dysfunction of the left ventricle, and thallium-201 myocardial scintigraphy showed diffuse heterogeneous perfusion. We diagnosed congestive heart failure because of cardiomyopathy induced by alpha-interferon therapy. Withdrawal of interferon therapy and the combination of an angiotensin-converting enzyme inhibitor, diuretics, and digitalis improved left ventricular systolic function. Furthermore, myocardial scintigraphy using [123I] beta-methyl-p-iodophenylpentadecanoic acid (123I-BMIPP) or [123 I]metaiodobenzylguanidine (123I-MIBG) revealed normal perfusion after the improvement of congestive heart failure. This is a rare case of interferon-induced cardiomyopathy that resulted in normal myocardial images in 123I-BMIPP and 123I-MIBG scintigrams after withdrawal of interferon therapy.

  11. MRI and MRA of kidney transplants - evaluation of vessels and perfusion

    International Nuclear Information System (INIS)

    Wiesner, W.; Pfammatter, T.; Krestin, G.P.; Debatin, J.F.

    1998-01-01

    Purpose: To document the value of fast contrast enhanced-sequences in the assessment of the vascular supply and parenchymal perfusion in renal transplants. Patients: 18 recipients of a renal transplant were examined with a 1.5-Tesla-MR-system. The protocol included fast contrast enhanced 3D MR angiography and coronal 2D GRE sequences. The transplant artery and vein were assessed as well as regional parenchymal perfusion. Results: 3D MRA detected three transplant artery stenoses and one occlusion. In addition, two renal vein thromboses and one compression were identified. Perfusion deficits were documented in 8 renal transplants: Renal infarction (n=4), cortical necrosis (n=2), acute tubular necrosis (n=1) and venous ischemia (n=1). Fluid collections were documented as well as dilatation of the collecting system and abnormalities of the surrounding tissues. Conclusion: Contrast enhanced MRI and MRA permit a comprehensive assessment of renal transplants without inducing nephrotoxicity. (orig.) [de

  12. Characteristics of Brain Perfusion in Patients of Parkinson's Disease

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Young Jin; Park, Min Jung; Kim, Jae Woo; Kang, Young Kang [Dong-A University College of Medicine, Busan (Korea, Republic of)

    2008-02-15

    It was well known that cerebral blood perfusion is normal or diffusely decreased in the majority of patients with Parkinson's disease (PD). Actually we interpreted brain perfusion SPECT images of PD patients in the clinical situation, we observed various cerebral perfusion patterns in patients with PD. So we performed brain perfusion SPECT to know the brain perfusion patterns of PD patients and the difference of perfusion patterns according to the sex and the age. Also we classified PD patients into small groups based on the brain perfusion pattern. Two hundred nineteen patients (M: 70, F: 149, mean age: 62.9{+-}6.9 y/o) who were diagnosed as PD without dementia clinically and 55 patients (M: 15, F: 40, mean age: 61.4{+-}9.2 y/o) as normal controls who had no past illness history were performed {sup 99m}Tc-HMPAO brain perfusion SPECT and neuropsychological test. At first, we compared all patients with PD and normal controls. Brain perfusion in left inferior frontal gyrus, left insula, left transverse temporal gyrus, left inferior parietal lobule, left superior parietal lobule, right precuneus, right caudate tail were lower in patients with PD than normal controls. Secondly, we compared male and female patients with PD and normal controls, respectively. Brain perfusion SPECT showed more decreased cerebral perfusion in left hemisphere than right side in both male and female patients compared to normal controls. And there was larger hypoperfusion area in female patients compared with male. Thirdly, we classified patients with PD and normal controls into 4 groups according to the age and compared brain perfusion respectively. In patient below fifties, brain perfusion in both occipitoparietal and left temporal lobe were lower in PD group. As the patients with PD grew older, hypoperfusion area were shown in both frontal, temporal and limbic lobes. Fourthly, We were able to divide patients into small groups based on cerebral perfusion pattern. There was normal

  13. An analysis of 'obstructive type' renography cases in 99mTc-DTPA renal dynamic imaging

    International Nuclear Information System (INIS)

    Wang Xinhui

    1991-01-01

    99m Tc-DTPA renal dynamic imaging and computed renography were performed in 61 cases. Renal blood perfusion imaging was also performed in some cases. Renography curves, which did not decrease in 20 min on all 61 cases (90 kidneys), are analysed in combination with renal dynamic imaging and renal perfusion imaging. 11 cases (12 kidneys) are only obstructive. 24 cases (32 kidneys) are obstructive and renal function impaired. Other 26 cases (46 kidneys) are renal function impaired or blood perfusion insufficient, but are not obstructive. The result demonstrated that the obstructive type renography may be obstructive or may be renal function impaired or blood supply insufficient. An analysis of renography in combination with renal dynamic imaging and blood perfusion imaging is more accurate than renography alone

  14. Cerebral perfusion in homogeneity in normal volunteers

    International Nuclear Information System (INIS)

    Gruenwald, S.M.; Larcos, G.

    1998-01-01

    Full text: In the interpretation of cerebral perfusion scans, it is important to know the normal variation in perfusion which may occur between the cerebral hemispheres. For this reason 24 normal volunteers with no neurological or psychiatric history, and who were on no medications, had 99m Tc-HMPAO brain SPECT studies using a single headed gamma camera computer system. Oblique, coronal and sagittal images were reviewed separately by two experienced observers and any differences were resolved by consensus. Semi-quantitation was performed by summing two adjacent oblique slices and drawing right and left mirror image ROIs corresponding to the mid section level of anterior and posterior frontal lobes, anterior and posterior parietal lobes, temporal lobes and cerebellum. From the mean counts per pixel, right: left ROI ratios and ROI: cerebellar ratios were calculated. On qualitative review 6/24 subjects had mild asymmetry in tracer distribution between right and left cerebral lobes. Semi-quantitation revealed a 5-10% difference in counts between right and left ROIs in 12/24 subjects and an additional three subjects had 10-20% difference in counts between right and left temporal lobes. This study demonstrates the presence of mild asymmetry of cerebral perfusion in a significant minority of normal subjects

  15. Dynamic renal scintigraphy of dissecting aneurysm of abdominal aorta

    International Nuclear Information System (INIS)

    Tsukamoto, Eriko; Itoh, Kazuo; Furudate, Masayori

    1990-01-01

    Dynamic renal scintigraphy on 15 patients with dissecting aneurysm of abdominal aorta extending below the renal arteries were retrospectively studied. The results were reviewed and classified into 3 types according to perfusion images and parenchymal tissue uptake: Type A--symmetric perfusion and parenchymal tissue uptake; Type B--asymmetrical perfusion and parenchymal tissue uptake; Type C--delayed perfusion of one kidney and symmetric parenchymal tissue uptake. The number of patients who showed Type A, Type B, and Type C were 3 cases, 6 cases, and 6 cases, respectively. In all Type A and 3 of Type B, perfusion of bilateral renal arteries was mainly from true lumen. In the remaining 3 cases of Type B, 2 had one renal artery obstructed with thrombus; 1 had a deformity of one kidney (the blood supply was mainly from a false lumen), suggestive of renal infarction. On the other hand, in all 6 Type C cases, the renal artery where perfusion was delayed was apparently supplied from false lumen. It is suggested in this retrospective study that the findings in Type C, where delayed perfusion of one kidney and symmetric parenchymal tissue uptake were found, were due to the presence of delayed flow through the false lumen; and therefore, specific to cases where the main blood supply of one renal artery from false lumen. (author)

  16. Impaired microcirculatory perfusion in a rat model of cardiopulmonary bypass : the role of hemodilution

    NARCIS (Netherlands)

    Koning, Nick J.; de lange, Fellery; Vonk, Alexander B. A.; Ahmed, Yunus; van den Brom, Charissa E.; Bogaards, Sylvia; van Meurs, Matijs; Jongman, Rianne M.; Schalkwijk, Casper G.; Begieneman, Mark P. V.; Niessen, Hans W.; Baufreton, Christophe; Boer, Christa

    2016-01-01

    Although hemodilution is attributed as the main cause of microcirculatory impairment during cardiopulmonary bypass (CPB), this relationship has never been investigated. We investigated the distinct effects of hemodilution with or without CPB on microvascular perfusion and subsequent renal tissue

  17. The usefulness of cardiofocal collimator in static renal imaging

    International Nuclear Information System (INIS)

    Evren, I.; Durak, H.; Degirmenci, B.; Derebek, E.; Oezbilek, E.; Capa, G.

    2001-01-01

    Static renal imaging is best performed using pinhole collimator. But this technique takes too much time and generally parallel hole collimators are preferred for static renal imaging in nuclear medicine departments. The purpose of this study was to investigate the usefulness of the cardio-focal collimator used for myocardial perfusion imaging in static renal scintigraphy

  18. Anatomical Comparison of the Renal Arteries in the Rabbit and European Hare

    Directory of Open Access Journals (Sweden)

    Flešárová S.

    2017-12-01

    Full Text Available The aim of this paper was to compare the level of origin of the renal arteries in the rabbit and hare. The study was carried out on ten adult rabbits and ten adult European hares using the corrosion cast technique. After the euthanasia, the vascular network was perfused with saline. Batson’s corrosion casting kit No. 17 was used as a casting medium. After polymerization of the medium, the maceration was carried out in KOH solution. We found variable levels of the origin of renal arteries in the rabbit, in the hare and between both species. In the rabbit, the right renal artery originated at the level of the second lumbar vertebra in 70 % of the cases and at the level of the first lumbar vertebra in 30 % of the cases, and the left-sided renal artery originated in 60 % of the cases at the level of the second lumbar vertebra and at the level of the third lumbar vertebra in 40 % of the cases. In the hare, the bilateral renal arteries originated at the level of the second lumbar vertebra. According to the results, it can be concluded that the origin level of the renal arteries from the abdominal aorta is more variable in the domesticated rabbit in comparison with the hare.

  19. The Renal Protective Effects of Corn Silk and Feijoa by using in situ Rat Renal System

    Directory of Open Access Journals (Sweden)

    Mohammad Karami

    2014-06-01

    Full Text Available Background: Corn silk (CS is widely used in Iranian traditional medicine. Feijoa sellowiana (FS, on the other hand, is a non-native plant widespread in the southern part of Iran. The aim of the present study was to examine the renal protective activity of CS and FS against dosage-induced ecstasy (MDMA by in situ rat renal perfusion (IRRP system. Methods: Hydro-alcoholic extracts of CS and FS (10, 20, 40 and 100 mg/ kg were studied for their renal protective activities by IRRP system. In this study, the kidneys were perfused with Kerbs-Henseleit buffer, containing different concentrations of hydro-alcoholic (HA extracts of CS and FS (10, 20, 40, 50, and 100mg/kg added to the buffer and perfused for two hours. During the perfusion, many factors, including urea, creatinine and GSH levels assessed as indicator of renal viability. Consequently, sections of renal tissue were examined for any histopathological changes. Results: The results showed that histopathological changes in renal tissue related to HA extract of CS AND FS concentrations dose-dependently. Doses of 50, 100 mg/kg caused significant histopathological changes (P<0.05. Glutathione (GSH levels of samples perfused by HA extract of CS and FS increased compared with the positive control group. Conclusion: Renal protective effects of CS and FS decrease lipid peroxidation, although other mechanisms may also be involved.

  20. Nifedipine and thallium-201 myocardial perfusion in progressive systemic sclerosis

    International Nuclear Information System (INIS)

    Kahan, A.; Devaux, J.Y.; Amor, B.

    1986-01-01

    Heart disease in patients with progressive systemic sclerosis may be due in part to myocardial ischemia caused by a disturbance of the coronary microcirculation. To determine whether abnormalities of myocardial perfusion in this disorder are potentially reversible, we evaluated the effect of the coronary vasodilator nifedipine on myocardial perfusion assessed by thallium-201 scanning in 20 patients. Thallium-201 single-photon-emission computerized tomography was performed under control conditions and 90 minutes after 20 mg of oral nifedipine. The mean (+/- SD) number of left ventricular segments with perfusion defects decreased from 5.3 +/- 2.0 to 3.3 +/- 2.2 after nifedipine (P = 0.0003). Perfusion abnormalities were quantified by a perfusion score (0 to 2.0) assigned to each left ventricular segment and by a global perfusion score (0 to 18) for the entire left ventricle. The mean perfusion score in segments with resting defects increased from 0.97 +/- 0.24 to 1.26 +/- 0.44 after nifedipine (P less than 0.00001). The mean global perfusion score increased from 11.2 +/- 1.7 to 12.8 +/- 2.4 after nifedipine (P = 0.003). The global perfusion score increased by at least 2.0 in 10 patients and decreased by at least 2.0 in only 1. These observations reveal short-term improvement in thallium-201 myocardial perfusion with nifedipine in patients with progressive systemic sclerosis. The results are consistent with a potentially reversible abnormality of coronary vasomotion in this disorder, but the long-term therapeutic effects of nifedipine remain to be determined

  1. Infarction of renal transplant with extrarenal excretion of Tc-99m MAG3 demonstrated by renal scintigraphy

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Kim, Min Woo; Sohn, Myung Hee

    2003-01-01

    A 38-year-old woman with end stage renal disease received a living related donor-renal transplant to the right iliac fossa. She developed anuria a week later. Tc-99m MAG 3 renal scintigraphy demonstrated no perfusion, uptake, or excretion of the radioactive tracer from the renal transplant. The expected area of the renal allograft appeared as a photopenic area with increased rim activity. The gallbladder and bowel activities were observed on delayed images at 24 hours. There was no blood flow within the renal artery on renal doppler examination. This case shows total absence of perfusion and function in the infarcted renal transplant with extrarenal excretion of Tc-99m MAG 3 caused by acute renal artery thrombosis

  2. Iridium-191m radionuclide angiocardiography detection and quantitation of left-to-rigth shunts

    International Nuclear Information System (INIS)

    Treves, S.; Fujii, A.; Cheng, C.; Kuruc, A.

    1983-01-01

    The purpose of this study was to determine whether Iridium-191m (Ir-191m) could replace Technetium-99m (Tc-99m) in the detection and quantitation of left-to-right shunts. It was demonstrated that Ir-191m radionuclide angiography is a safe, rapid, and accurate method for the detection and quantitation of left-to-right shunts with very low radiation dose to the patient. It is also possible with this radiotracer to evaluate other aspects of the anatomy and physiology of the circulation such as ventricular function, patency of major vessels, renal and cerebral perfusion. Further improvements on 0s-191 production, generator design and gamma cameras would expand the use of this ultrashort-lived radionuclide

  3. Perioperative acute renal failure.

    LENUS (Irish Health Repository)

    Mahon, Padraig

    2012-02-03

    PURPOSE OF REVIEW: Recent biochemical evidence increasingly implicates inflammatory mechanisms as precipitants of acute renal failure. In this review, we detail some of these pathways together with potential new therapeutic targets. RECENT FINDINGS: Neutrophil gelatinase-associated lipocalin appears to be a sensitive, specific and reliable biomarker of renal injury, which may be predictive of renal outcome in the perioperative setting. For estimation of glomerular filtration rate, cystatin C is superior to creatinine. No drug is definitively effective at preventing postoperative renal failure. Clinical trials of fenoldopam and atrial natriuretic peptide are, at best, equivocal. As with pharmacological preconditioning of the heart, volatile anaesthetic agents appear to offer a protective effect to the subsequently ischaemic kidney. SUMMARY: Although a greatly improved understanding of the pathophysiology of acute renal failure has offered even more therapeutic targets, the maintenance of intravascular euvolaemia and perfusion pressure is most effective at preventing new postoperative acute renal failure. In the future, strategies targeting renal regeneration after injury will use bone marrow-derived stem cells and growth factors such as insulin-like growth factor-1.

  4. Dynamic renal scintigraphy in aortic disorders

    International Nuclear Information System (INIS)

    Terae, Satoshi; Itoh, Kazuo; Tsukamoto, Eriko; Nakada, Kunihiro; Fujimori, Kenji; Hashimoto, Masato; Tanabe, Tatsuzo; Furudate, Masayori; Irie, Goro

    1986-01-01

    Dynamic renal scintigraphy has been reviewed for evaluation of renal arterial involvement in aortic disorders such as arteriosclerosis obliterans, abdominal aortic aneurysm and dissecting aneurysm. As a diagnostic finding and parameters, we used blood perfusion images of both kidneys and relative split renal function index obtained with analysis of the time-activity curves which were generated using a renal region of interest. In the diagnosis of unilateral renal arterial involvement, sensitivity and specificity of blood perfusion images were 100 % (9/9) and 77 % (10/13) and those of relative split renal function index were 78 % (7/9) and 92 % (12/13), respectively. Dynamic renal scintigraphy was useful for evaluating unilateral renal arterial involvement in aortic diseases. However, scintigraphic diagnosis of bilateral renal arterial involvement were difficult. And in a severe case, we could not differentiate renal parenchymal damage due to renovascular involvement from senile renal dysfunction or hypertensive renal disease which is often a cause of aortic disorders. (author)

  5. Ex-vivo machine perfusion for kidney preservation.

    Science.gov (United States)

    Hamar, Matyas; Selzner, Markus

    2018-06-01

    Machine perfusion is a novel strategy to decrease preservation injury, improve graft assessment, and increase organ acceptance for transplantation. This review summarizes the current advances in ex-vivo machine-based kidney preservation technologies over the last year. Ex-vivo perfusion technologies, such as hypothermic and normothermic machine perfusion and controlled oxygenated rewarming, have gained high interest in the field of organ preservation. Keeping kidney grafts functionally and metabolically active during the preservation period offers a unique chance for viability assessment, reconditioning, and organ repair. Normothermic ex-vivo kidney perfusion has been recently translated into clinical practice. Preclinical results suggest that prolonged warm perfusion appears superior than a brief end-ischemic reconditioning in terms of renal function and injury. An established standardized protocol for continuous warm perfusion is still not available for human grafts. Ex-vivo machine perfusion represents a superior organ preservation method over static cold storage. There is still an urgent need for the optimization of the perfusion fluid and machine technology and to identify the optimal indication in kidney transplantation. Recent research is focusing on graft assessment and therapeutic strategies.

  6. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae

    2005-01-01

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 ± 8.5%, range:3 ∼ 35%) and mild to moderate severity (-71 ± 42.7%, range:-217 ∼ -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome

  7. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae [Donga University College of Medicine, Busan (Korea, Republic of)

    2005-02-15

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 {+-} 8.5%, range:3 {approx} 35%) and mild to moderate severity (-71 {+-} 42.7%, range:-217 {approx} -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome.

  8. The effects of angiotensin II receptor antagonist (candesartan on rat renal vascular resistance

    Directory of Open Access Journals (Sweden)

    Supatraviwat, J

    2004-05-01

    Full Text Available The present study aimed to investigate the action of angiotensin II (AII on renal perfusion pressure and renal vascular resistance using noncompetitive AT1-receptor antagonist (candesartan or CV 11974. Experiments were performed in isolated kidney of adult male Wistar rats. Kreb's Henseleit solution was perfused into the renal artery at the rate of 3.5 ml/min. This flow rate was designed in order to maintain renal perfusion pressure between 80-120 mm Hg. Dose-response relationship between perfusion flow rate and AII concentration were studied. Renal perfusion pressure in response to 1, 10 and 100 nM AII were increased from basal perfusion pressure of 94±8 mm Hg to 127±6, 157±12 and 190±16 mm Hg, respectively. Administration of perfusate containing 11.4 μM candesartan for 30 min had no effect on the basal perfusion pressure. However, this significantly reduced renal perfusion pressure in the presence of AII (1, 10 and 100 nM by 39%, 47% and 61%, (n=7, P<0.05 respectively. At the basal perfusion pressure, calculated renal vascular resistance was 27±2 mm Hg · min · ml-1. However, the vascular resistance were found to be 41±1, 45±2 and 47±2 mm Hg · min · ml-1 when 1, 10 and 100 nM AII were added. Moreover, this dose of candesartan also showed a significant decrease in renal vascular resistance at the corresponding doses of AII by 38%, 48% and 43%, (n=7, P<0.05 respectively. The higher dose of candesartan (22.7 μM completely inhibited the action of 1, 10 and 100 nM AII on renal vasoconstriction. These results may indicate that the action of AII on renal vascular resistance is via AT1-receptor, at least in rat isolated perfusion kidney.

  9. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  10. Scintigraphy of renal transplant

    International Nuclear Information System (INIS)

    Ramackers, J.M.; Marrast, A.C.; Touraine, J.L.; Peyrin, J.O.

    1995-01-01

    Scintigraphy is useful for monitoring perfusion and function of renal transplant, as well as for diagnosing miscellaneous surgical. This non-invasive imaging technique, which uses no deleterious products, is an attractive alternative for patients. This is especially true for those patients in early post-transplant course, with immunity depression and often impairment of renal function. Otherwise, multiple indices with a large range of inter-patient values has not favoured a methodological and interpretative consensus. Furthermore, the poor specificity of renogram patterns does not allow for discrimination of all etiologies with only one scintigraphy. Nevertheless, follow-up with iterative scintigraphy may be helpful due to the high intra-patient reproducibility and to the early appreciate change of parameters, according to clinical and histological renal post-transplant outcome. (authors). 43 refs., 8 figs

  11. Left ventricular wall stress and sarcoplasmic reticulum Ca(2+)-ATPase gene expression in renal hypertensive rats: dose-dependent effects of ACE inhibition and AT1-receptor blockade.

    Science.gov (United States)

    Zierhut, W; Studer, R; Laurent, D; Kästner, S; Allegrini, P; Whitebread, S; Cumin, F; Baum, H P; de Gasparo, M; Drexler, H

    1996-05-01

    Cardiac hypertrophy is associated with altered Ca2+ handling and may predispose to the development of LV dysfunction and cardiac failure. At the cellular level, the re-expression of ANF represents a well-established marker of myocyte hypertrophy while the decreased expression of the sarcoplasmatic reticulum (SR) Ca(2+)-ATPase is thought o play a crucial role in the alterations of Ca2+ handling and LV function. We assessed the dose-dependent effect of chronic ACE inhibition or AT1 receptor blockade on cardiac function in relation to the cardiac expression of the SR Ca(2+)-ATPase and ANF. Renal hypertensive rats (2K-1C) were treated for 12 weeks with three different doses of the ACE inhibitor benazepril, the AT1-receptor antagonist valsartan (each drug 0.3, 3, and 10 mg/kg per day i.p.) or placebo. LV dimensions, hypertrophy and wall stress were determined in vivo by magnetic resonance imaging and the gene expressions of ANF and SR Ca(2+)-ATPase were quantified by Northern blot. Low doses of both drugs did not affect blood pressure, hypertrophy, systolic wall stress and the ANF and SR Ca(2+)-ATPase gene expression. High doses of each drug reduced systolic blood pressure, wall stress, and LV hypertrophy to a similar extent and to values comparable to normotensive, age-matched rats. In addition, high dose treatment reduced LV end-systolic and end-diastolic volume as compared to untreated 2K-1C animals and normalized the mRNA levels of both ANF and SR Ca(2+)-ATPase (as compared to normotensive animals). We conclude that in this model, high doses of ACE inhibition and AT1-receptor blockade are necessary to normalize systolic blood pressure, LV hypertrophy and systolic LV wall stress which, in turn, is associated with restoration of a normal cardiac phenotype with respect to SR Ca(2+)-ATPase and ANF and normalization of cardiac function.

  12. Nuclear medicine in the management of renal vein thrombosis post renal transplantation - a case study

    International Nuclear Information System (INIS)

    Waran, L.; Unger, S.

    2005-01-01

    Renal scintigraphy allows the assessment of both perfusion and function of the transplanted kidney. Treatment of renal dysfunction depends on its cause. Nuclear medicine plays an important role in determining the cause of renal dysfunction, thereby providing appropriate intervention. Renal vein thrombosis (RVT) is a rare occurrence (1-2%) in renal transplants, and constitutes a surgical emergency. Early detection of RVT is critical in order to prevent infarction and subsequent loss of the graft. A 43-year-old woman with end stage renal disease as a result of diabetic nephropathy underwent transplantation of a living-related-donor kidney. The patient underwent a post operative Tc-MAG, scan that demonstrated good perfusion to the graft. Three days post-transplantation, the patient complained of acute pain and swelling. Creatinine increased from 0.13 to 0.16. and urine output decreased. The m Tc-MAG, scan revealed dramatic deterioration, with absent perfusion to the kidney. Immediate allograft exploration was performed in theatre and RVT was revealed, followed by thrombectomy. A follow-up renal scan performed the next day demonstrated a viable kidney with improved but patchy perfusion throughout, indicating patchy cortical infarction as well as acute tubular necrosis. On day 19. the patient again complained of severe pain over the graft, and the 99 mTc-MAG, scan again revealed absent perfusion, this time with residual function. Further surgical exploration confirmed re-thrombosis of the renal vein, and subsequent genetic analysis revealed that the patient had a rare mutation of her clotting Factor V gene, leading to an increased thrombogenic tendency. Following full anticoagulation, the patient was finally discharged on day 58. This case illustrates a rare case of renal allograft infarction secondary to renal vein thrombosis. The ability of nuclear medicine to provide immediate functional information helped confirm the diagnosis, and salvage the kidney

  13. Impairment of myocardial perfusion in children with sickle cell disease

    International Nuclear Information System (INIS)

    Maunoury, C.; Acar, P.; Montalembert, M. de

    2003-01-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 ± 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 ± 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  14. Arteriovenous renal replacement therapy in end-stage left-sided heart failure patients has a detrimental effect on patients with impaired right ventricular function.

    Science.gov (United States)

    Repasos, Evangelos; Kaldara, Elisabeth; Pantsios, Christos; Kapelios, Chris; Nana, Emmeleia; Vernadakis, Spiridon; Melexopoulou, Christina; Malliaras, Konstantinos; Boletis, John; Nanas, John N

    Chronic intermittent renal replacement therapy(RRT) is an alternate method of decongestion for patients presenting with diuretic-resistant, end-stage heart failure(HF) and cardiorenal syndrome. The optimal method of vascular access has not been confirmed. This study investigated the 6-month outcomes of patients with end-stage HF after the creation of arteriovenous communications (AVC) compared with other means of RRT. We treated 40 patients with chronic, intermittent, ambulatory RRT, of whom 15 (37.5%; Group A) underwent creation of AVC, and 25 (62.5%; Group B) received intraperitoneal (n=6) or internal jugular catheters (n=19) with the goal of achieving body weight stabilization and relief from congestion. The characteristics of the two groups were similar. According to Cox regression analysis, the 6-month rate of death or re-hospitalization for HF was significantly higher in Group A (73%) than in Group B (44%); hazard ratio (HR): 2.58; 95% confidence interval (CI) 1.2-6.2; P=0.02. Over a 6-month follow-up, the cumulative survival was significantly shorter (P=0.03) in Group A (13.8±10 weeks) than in Group B (20.7±7 weeks). In the 15 patients who received AVC, the only independent predictor of adverse outcome at 6 months was serum total bilirubin concentration (HR 2.5; 95% CI 1.1-5.7, p=0.02), whereas in the 25 patients who underwent other means of RRT, pulmonary vascular resistance (PVR) was identified as a risk factor for hospitalization or death at 1-year follow-up (HR 1.26; 95% CI 1.1-1.57, p=0.04). In patients with end-stage HF, the creation of AVC for intermittent RRT was followed by a significant increase in morbidity and mortality in comparison to the safe and effective placement of permanent central venous catheters. Patients with elevated PVR seem to comprise a group at high risk for adverse outcomes after central catheter insertion. Copyright © 2016 Hellenic Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  15. Renal haemodynamic in essential hypertension assessed by 133Xe washout and selective renal angiography

    International Nuclear Information System (INIS)

    Gatta, A.; Merkel, C.; Pessina, A.C.; Milani, L.; Sacerdoti, D.; Zuin, R.

    1982-01-01

    The renal and intrarenal haemodynamic pattern in 17 patients with essential hypertension of different severity and duration was studied by means of the 133-Xenon washout technique and the selective renal angiography. The mean and the cortical renal blood flows were on average significantly decreased as compared to the controls. A good agreement was found between the reduction in renal perfusion and the degree of vascular abnormalities as shown by angiography; on the contrary no correlation was found between the impairment in renal blood flow and the degree and/or duration of hypertension

  16. Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model.

    Science.gov (United States)

    Artz, Nathan S; Wentland, Andrew L; Sadowski, Elizabeth A; Djamali, Arjang; Grist, Thomas M; Seo, Songwon; Fain, Sean B

    2011-02-01

    The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. Fluorescent microsphere and FAIR-ASL perfusion were compared in the cortex of the kidney for 11 swine across 4 interventional time points: (1) under baseline conditions, (2) during an acetylcholine and fluid bolus challenge to increase perfusion, (3) initially after switching to isoflurane anesthesia, and (4) after 2 hours of isoflurane anesthesia. In 10 of the 11 swine, a bag of ice was placed on the hilum of 1 kidney at the beginning of isoflurane administration to further reduce perfusion in 1 kidney. Both ASL and microspheres tracked the expected cortical perfusion changes (P values were systematically lower compared with microsphere perfusion. Very good correlation (r = 0.81, P values in the expected physiologic range (microsphere perfusion values saturated for perfusion >550 mL/min/100 g. Cortical perfusion measured with ASL correlated with microspheres and reliably detected changes in renal perfusion in response to physiologic challenge.

  17. Bilateral triple renal arteries

    International Nuclear Information System (INIS)

    Pestemalci, Turan; Yildiz, Yusuf Zeki; Yildirim, Mehmet; Mavi, Ayfer; Gumusburun, Erdem

    2009-01-01

    Knowledge of the variations of the renal artery has grown in importance with increasing numbers of renal transplants, vascular reconstructions and various surgical and radio logic techniques being performed in recent years. We report the presence of bilateral triple renal arteries, discovered on routine dissection of a male cadaver. On the right side, one additional renal artery originated from the abdominal aorta (distributed to superior pole of the kidney) and one other originated from the right common iliac artery (distributed to lower pole of the kidney). On the left side, both additional renal arteries originated from the abdominal aorta. Our observation has been compared with variations described in the literature and their clinical importance has been emphasized. (author)

  18. Renal sympathetic denervation for treatment of patients with heart failure: summary of the available evidence.

    Science.gov (United States)

    Nammas, Wail; Koistinen, Juhani; Paana, Tuomas; Karjalainen, Pasi P

    2017-08-01

    Heart failure syndrome results from compensatory mechanisms that operate to restore - back to normal - the systemic perfusion pressure. Sympathetic overactivity plays a pivotal role in heart failure; norepinephrine contributes to maintenance of the systemic blood pressure and increasing preload. Cardiac norepinephrine spillover increases in patients with heart failure; norepinephrine exerts direct toxicity on cardiac myocytes resulting in a decrease of synthetic activity and/or viability. Importantly, cardiac norepinephrine spillover is a powerful predictor of mortality in patients with moderate to severe HF. This provided the rationale for trials that demonstrated survival benefit associated with the use of beta adrenergic blockers in heart failure with reduced ejection fraction. Nevertheless, the MOXCON trial demonstrated that rapid uptitration of moxonidine (inhibitor of central sympathetic outflow) in patients with heart failure was associated with excess mortality and morbidity, despite reduction of plasma norepinephrine. Interestingly, renal norepinephrine spillover was the only independent predictor of adverse outcome in patients with heart failure, in multivariable analysis. Recently, renal sympathetic denervation has emerged as a novel approach for control of blood pressure in patients with treatment-resistant hypertension. This article summarizes the available evidence for the effect of renal sympathetic denervation in the setting of heart failure. Key messages Experimental studies supported a beneficial effect of renal sympathetic denervation in heart failure with reduced ejection fraction. Clinical studies demonstrated improvement of symptoms, and left ventricular function. In heart failure and preserved ejection fraction, renal sympathetic denervation is associated with improvement of surrogate endpoints.

  19. Predictors of abnormal heart rate response to dipyridamole in patients undergoing myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    De Souza Leao Lima, R.; Machado, L.; Azevedo, A.B.; De Lorenzo, A.

    2011-01-01

    The objective of this study was to identify predictors of abnormal HR response to dipyridamole (DIP) in patients undergoing myocardial perfusion SPECT (MPS). Patients with a reduced heart rate (HR) response to DIP have higher cardiac mortality, but the mechanism is unknown. We studied 432 patients who underwent dual-isotope gated MPS. DIP (0.56 mg/kg) was infused over 4 min, and Tc-99m tetrofosmin was injected 3 min after the end of the infusion. MPS was semiquantitatively interpreted. Left ventricular ejection fraction (LVEF) and volumes were automatically calculated. The population was categorized into quartiles according to HR ratio, and characteristics in each quartile were compared. Logistic regression analysis was performed to identify predictors of abnormal HR response, using the lowest quartile as the independent variable. Patients with abnormal HR response were more frequently without chest pain, with a history of chronic renal failure and taking digoxin. Baseline HR was higher and had fewer symptoms during stress. The stress and rest perfusion defects were greater, but reversibility was not; in addition, LVEF was lower. Multivariable logistic regression analysis demonstrated that the independent predictors of abnormal HR response were baseline HR and low LVEF. LV dysfunction is an independent predictor of abnormal HR response to DIP, and the association between low LVEF and low HR ratio may explain the link between abnormal HR ratio and increased mortality. (author)

  20. Lung Perfusion SPECT: Application in a Patient With Tetralogy of Fallot and Suspected Pulmonary Thromboemboli

    International Nuclear Information System (INIS)

    Ranji Amjad, Mina; Abbasi, Mehrshad; Farzanehfar, Saeed

    2015-01-01

    A 22-year-old woman presented with acute left-sided pleuritic chest pain and dyspnea 6 days after surgery for revision of the stenotic central aortopulmonary shunt. She had a history of tetralogy of Fallot (TOF), pulmonary valve stenosis, ventricular septal defect and major aortopulmonary collateral artery. Her Waterston shunt was placed when she was 5 years old and stented and re-dilated after stenosis. Acute pulmonary thromboemboli (PTE) was suspected and pulmonary perfusion scan was performed with 4 mCi 99m Technetium labeled macroaggregated albumin. The left lung was globally hypoperfused with evident uptake in the brain, renal parenchyma and thyroid. SPECT images revealed a segmental wedge-shaped peripheral defect in the posterior segment of the left upper lobe. The scan was interpreted as acute/chronic PTE or vascular abnormality. CT angiography excluded PTE; nevertheless the patient was treated with a therapeutic dose of heparin changed to warfarin and was discharged with improvement of the symptoms. Pulmonary artery angiography was not performed

  1. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo

    2010-01-01

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years ±10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07±0.62 ml min -1 g -1 , whereas stress MBF was 3.15±1.93 ml min -1 g -1 and the MPR was 3.33±1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, β=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, β=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  2. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo [Mie Univ., Graduate School of Medicine, Tsu, Mie (Japan)

    2010-11-15

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years {+-}10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07{+-}0.62 ml min{sup -1} g{sup -1}, whereas stress MBF was 3.15{+-}1.93 ml min{sup -1} g{sup -1} and the MPR was 3.33{+-}1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, {beta}=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, {beta}=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  3. Renal blood flow and metabolism after cold ischaemia

    DEFF Research Database (Denmark)

    Henriksen, J H; Petersen, H K

    1984-01-01

    Peroperative measurements of renal blood flow (RBF), renal O2-uptake, and renal venous lactate/pyruvate (L/P) ratio were performed before and after a period of 30-71 min of hypothermic (10-15 degrees C) renal ischaemia in nine patients, undergoing surgery for renal calculi. Before ischaemia, RBF.......01) immediately after re-established perfusion and 36% (P less than 0.02) 30 min later. In one additional patient, who had a short warm ischaemia (8 min), the flow pattern was the same. As arterial pressure remained constant, the reduced RBF signifies an increased renal vascular resistance. Renal O2-uptake...... and renal venous L/P ratio were almost constant, indicating no significant anaerobic processes being involved in the flow response. None of the patients showed any signs of reactive hyperaemia. It is concluded that hypothermic renal ischaemia may be followed by an increased renal vascular resistance even...

  4. Hepatic perfusion changes in an experimental model of acute pancreatitis: Evaluation by perfusion CT

    Energy Technology Data Exchange (ETDEWEB)

    Tutcu, Semra [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey); Serter, Selim, E-mail: serterselim@gmail.co [Department of Radiology, Celal Bayar University, School of Medicine, Manisa (Turkey); Kaya, Yavuz; Kara, Eray [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey); Nese, Nalan [Department of Pathology, Celal Bayar University, School of Medicine, Manisa (Turkey); Pekindil, Goekhan [Department of Radiology, Celal Bayar University, School of Medicine, Manisa (Turkey); Coskun, Teoman [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey)

    2010-08-15

    Purpose: It is known that acute pancreatitis may cause secondary changes in several organs. Liver is one of these involved organs. In different experimental studies hepatic damages were shown histopathologically in acute pancreatitis but there are a few studies about perfusion disorders that accompany these histopathologic changes. Perfusion CT (pCT) provides the ability to detect regional and global alterations in organ blood flow. The purpose of the study was to describe hepatic perfusion changes in experimental acute pancreatitis model with pCT. Materials and methods: Forty Sprague-Dawley rats of both genders with average weights of 250 g were used. Rats were randomized into two groups. Twenty rats were in control group and 20 in acute pancreatitis group. pCT was performed. Perfusion maps were formed by processing the obtained images with perfusion CT software. Blood flow (BF) and blood volume (BV) values were obtained from these maps. All pancreatic and liver tissues were taken off with laparotomy and histopathologic investigation was performed. Student's t test was used for statistical analyses. Results: In pCT we found statistically significant increase in blood volume in both lobes of liver and in blood flow in right lobe of the liver (p < 0.01). Although blood flow in left lobe of the liver increased, it did not reach statistical significance. Conclusion: The quantitative analysis of liver parenchyma with pCT showed that acute pancreatitis causes a significant perfusion changes in the hepatic tissue. Systemic mediators seem to be effective as well as local inflammatory changes in perfusion changes.

  5. Hepatic perfusion changes in an experimental model of acute pancreatitis: Evaluation by perfusion CT

    International Nuclear Information System (INIS)

    Tutcu, Semra; Serter, Selim; Kaya, Yavuz; Kara, Eray; Nese, Nalan; Pekindil, Goekhan; Coskun, Teoman

    2010-01-01

    Purpose: It is known that acute pancreatitis may cause secondary changes in several organs. Liver is one of these involved organs. In different experimental studies hepatic damages were shown histopathologically in acute pancreatitis but there are a few studies about perfusion disorders that accompany these histopathologic changes. Perfusion CT (pCT) provides the ability to detect regional and global alterations in organ blood flow. The purpose of the study was to describe hepatic perfusion changes in experimental acute pancreatitis model with pCT. Materials and methods: Forty Sprague-Dawley rats of both genders with average weights of 250 g were used. Rats were randomized into two groups. Twenty rats were in control group and 20 in acute pancreatitis group. pCT was performed. Perfusion maps were formed by processing the obtained images with perfusion CT software. Blood flow (BF) and blood volume (BV) values were obtained from these maps. All pancreatic and liver tissues were taken off with laparotomy and histopathologic investigation was performed. Student's t test was used for statistical analyses. Results: In pCT we found statistically significant increase in blood volume in both lobes of liver and in blood flow in right lobe of the liver (p < 0.01). Although blood flow in left lobe of the liver increased, it did not reach statistical significance. Conclusion: The quantitative analysis of liver parenchyma with pCT showed that acute pancreatitis causes a significant perfusion changes in the hepatic tissue. Systemic mediators seem to be effective as well as local inflammatory changes in perfusion changes.

  6. Conversion of p-tyrosine to p-tyramine in the isolated perfused rat kidney: Modulation by perfusate concentrations of p-tyrosine

    International Nuclear Information System (INIS)

    Brier, M.E.; Bowsher, R.R.; Henry, D.P.; Mayer, P.R.

    1991-01-01

    The authors used the isolated perfused rat kidney to evaluate the role of renal decarboxylation of p-tyrosine as the source of urinary p-tyramine. Kidneys were perfused with concentrations of p-tyrosine ranging from 0.02 mM to 2.0 mM. p-Tyramine was measured by a sensitive and specific radioenzymatic assay. An increase in the perfusate concentration of p-tyrosine resulted in a significant increase in p-tyramine production that was blocked by the addition of NSD-1015, an inhibitor of aromatic-1-amino decarboxylase (AADC). They conclude p-tyrosine is the precursor for the renal production of p-tyramine, renal AADC catalyzes the formation of urinary p-tyramine, synthesized p-tyramine is predominantly excreted in the urine, and p-tyramine synthesis is modulated by the arterial delivery of p-tyrosine to the kidney

  7. The renal scan in pregnant renal transplant patients

    International Nuclear Information System (INIS)

    Goldstein, H.A.; Ziessman, H.A.; Fahey, F.H.; Collea, J.V.; Alijani, M.R.; Helfrich, G.B.

    1985-01-01

    With the greater frequency of renal transplant surgery, more female pts are becoming pregnant and carrying to term. In the renal allograft blood vessels and ureter may be compressed resulting in impaired renal function and/or, hypertension. Toxemia of pregnancy is seen more frequently than normal. Radionuclide renal scan monitoring may be of significant value in this high risk obstetrical pt. After being maintained during the pregnancy, renal function may also deteriorate in the post partum period. 5 pregnant renal transplant pts who delivered live babies had renal studies with Tc-99m DTPA to assess allograft perfusion and function. No transplanted kidney was lost during or after pregnancy as a result of pregnancy. No congenital anomalies were associated with transplant management. 7 studies were performed on these 5 pts. The 7 scans all showed the uterus/placenta. The bladder was always distorted. The transplanted kidney was rotated to a more vertical position in 3 pts. The radiation dose to the fetus is calculated at 0.024 rad/mCi administered. This study demonstrates the anatomic and physiologic alterations expected in the transplanted kidney during pregnancy when evaluated by renal scan and that the radiation burden may be acceptable in management of these pts

  8. Perfusion-weighted MR imaging in persistent hemiplegic migraine

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Menjot de Champfleur, Nicolas; Carra-Dalliere, Clarisse; Le Bars, Emmanuelle; Bonafe, Alain; Thouvenot, Eric; Roubertie, Agathe

    2012-01-01

    Hemiplegic migraine is a rare type of migraine that has an aura characterized by the presence of motor weakness, which may occasionally last up to several days, and then resolve without sequela. Pathogenesis of migraine remains unclear and, recently, perfusion-weighted imaging (PWI) has provided a non-invasive method to study hemodynamic changes during acute attacks. Two female patients were admitted in our hospital suffering from prolonged hemiparesis. In both cases, they underwent MRI examination using a 1.5 T magnet including axial diffusion-weighted and perfusion sequences. From each perfusion MRI acquisition two regions of interest were delineated on each hemisphere and, the index of flow, cerebral blood volume, mean transit time, and time to peak were recorded and asymmetry indices from each perfusion parameter were calculated. Perfusion alterations were detected during the attacks. In one case, we observed, after 3 h of left hemiparesia, hypoperfusion of the right hemisphere. In the other case, who presented a familial hemiplegic migraine attack, on the third day of a persistent aura consisting of right hemiplegia and aphasia, PWI revealed hyperperfusion of the left hemisphere. Asymmetry indices for temporal parameters (mean transit time and time to peak) were the most sensitive. These findings resolved spontaneously after the attacks without any permanent sequel or signs of cerebral ischemia on follow-up MRI. PWI should be indicated for patients with migraine attacks accompanied by auras to assess the sequential changes in cerebral perfusion and to better understand its pathogenesis. (orig.)

  9. Perfusion-weighted MR imaging in persistent hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle; Menjot de Champfleur, Nicolas; Carra-Dalliere, Clarisse; Le Bars, Emmanuelle; Bonafe, Alain; Thouvenot, Eric [Hopital Gui de Chauliac, Service de Neuroradiologie, Montpellier (France); Roubertie, Agathe [Hopital Gui de Chauliac, Service de Neuropediatrie, Montpellier (France)

    2012-03-15

    Hemiplegic migraine is a rare type of migraine that has an aura characterized by the presence of motor weakness, which may occasionally last up to several days, and then resolve without sequela. Pathogenesis of migraine remains unclear and, recently, perfusion-weighted imaging (PWI) has provided a non-invasive method to study hemodynamic changes during acute attacks. Two female patients were admitted in our hospital suffering from prolonged hemiparesis. In both cases, they underwent MRI examination using a 1.5 T magnet including axial diffusion-weighted and perfusion sequences. From each perfusion MRI acquisition two regions of interest were delineated on each hemisphere and, the index of flow, cerebral blood volume, mean transit time, and time to peak were recorded and asymmetry indices from each perfusion parameter were calculated. Perfusion alterations were detected during the attacks. In one case, we observed, after 3 h of left hemiparesia, hypoperfusion of the right hemisphere. In the other case, who presented a familial hemiplegic migraine attack, on the third day of a persistent aura consisting of right hemiplegia and aphasia, PWI revealed hyperperfusion of the left hemisphere. Asymmetry indices for temporal parameters (mean transit time and time to peak) were the most sensitive. These findings resolved spontaneously after the attacks without any permanent sequel or signs of cerebral ischemia on follow-up MRI. PWI should be indicated for patients with migraine attacks accompanied by auras to assess the sequential changes in cerebral perfusion and to better understand its pathogenesis. (orig.)

  10. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning

    NARCIS (Netherlands)

    Kunst, P. W.; Vonk Noordegraaf, A.; Hoekstra, O. S.; Postmus, P. E.; de Vries, P. M.

    1998-01-01

    Electrical impedance tomography (EIT) is a technique that makes it possible to measure ventilation and pulmonary perfusion in a volume that approximates to a 2D plane. The possibility of using EIT for measuring the left-right division of ventilation and perfusion was compared with that of

  11. Reversible changes in echo planar perfusion- and diffusion-weighted MRI in status epilepticus

    International Nuclear Information System (INIS)

    Flacke, S.; Keller, E.; Urbach, H.; Wuellner, U.; Hamzei, F.

    2000-01-01

    Perfusion imaging (PI) demonstrated increased perfusion and diffusion-weighted imaging (DWI) showed high signal limited to the left temporoparietal cortex in a 68-year-old man with nonconvulsive status epilepticus. The EEG showed a slow delta-wave focus. The patient recovered and PI, DWI and EEG changes completely resolved. (orig.)

  12. Reversible changes in echo planar perfusion- and diffusion-weighted MRI in status epilepticus

    Energy Technology Data Exchange (ETDEWEB)

    Flacke, S; Keller, E; Urbach, H [Dept. of Radiology, Univ. of Bonn (Germany); Wuellner, U; Hamzei, F [Dept. of Neurology, Univ. of Bonn (Germany)

    2000-02-01

    Perfusion imaging (PI) demonstrated increased perfusion and diffusion-weighted imaging (DWI) showed high signal limited to the left temporoparietal cortex in a 68-year-old man with nonconvulsive status epilepticus. The EEG showed a slow delta-wave focus. The patient recovered and PI, DWI and EEG changes completely resolved. (orig.)

  13. Renal Infarction from Type B Aortic Dissection

    Directory of Open Access Journals (Sweden)

    Marit Tweet

    2017-07-01

    Full Text Available History of present illness: A 69-year-old-female with a medical history of hypertension presented to the emergency department (ED complaining of sudden onset of lower back and abdominal pain. Eight hours prior to presentation she reported turning to grab something on another counter and felt a sudden onset sharp pain in her lower back. She began to notice ill-defined abdominal pain, although she denied any shortness of breath, chest pain, numbness, weakness, or urologic symptoms. Her vital signs on presentation to the ED were temperature 36.5˚C, blood pressure 143/88, heart rate 84, respiratory rate 14, and oxygen saturation 93% on room air. On arrival, the patient was in significant discomfort and was rolling on the bed due to pain. Although she appeared to be in moderate distress she had minimal, if any, tenderness on abdominal exam, and only mild left lower back tenderness to palpation. This disconnect between the patient’s apparent discomfort and the lack of physical exam findings prompted the ordering of a computed tomography angiography (CTA of the abdomen/pelvis with greatest suspicion for abdominal aortic aneurysm. Significant findings: Initial abdominal images demonstrated a dissection flap; therefore, a CTA of the chest was also obtained. These images revealed a Stanford type B aortic dissection beginning just distal to the left subclavian artery and extending to the origin of the inferior mesenteric artery. The right renal artery arose from the true lumen of the dissection while the left renal artery arose from the false lumen. This case is interesting as imaging shows the lack of perfusion to the left kidney, residing in the retroperitoneum, which correlates with her non-descript abdominal and left flank pain. Discussion: Aortic dissection is defined as a tear within the wall of the aorta that allows blood to track between intima and media layers. A dissection is classified as Stanford Type A if it involves any portion of the

  14. Hypoplastic left heart syndrome

    Directory of Open Access Journals (Sweden)

    Thiagarajan Ravi

    2007-05-01

    Full Text Available Abstract Hypoplastic left heart syndrome(HLHS refers to the abnormal development of the left-sided cardiac structures, resulting in obstruction to blood flow from the left ventricular outflow tract. In addition, the syndrome includes underdevelopment of the left ventricle, aorta, and aortic arch, as well as mitral atresia or stenosis. HLHS has been reported to occur in approximately 0.016 to 0.036% of all live births. Newborn infants with the condition generally are born at full term and initially appear healthy. As the arterial duct closes, the systemic perfusion becomes decreased, resulting in hypoxemia, acidosis, and shock. Usually, no heart murmur, or a non-specific heart murmur, may be detected. The second heart sound is loud and single because of aortic atresia. Often the liver is enlarged secondary to congestive heart failure. The embryologic cause of the disease, as in the case of most congenital cardiac defects, is not fully known. The most useful diagnostic modality is the echocardiogram. The syndrome can be diagnosed by fetal echocardiography between 18 and 22 weeks of gestation. Differential diagnosis includes other left-sided obstructive lesions where the systemic circulation is dependent on ductal flow (critical aortic stenosis, coarctation of the aorta, interrupted aortic arch. Children with the syndrome require surgery as neonates, as they have duct-dependent systemic circulation. Currently, there are two major modalities, primary cardiac transplantation or a series of staged functionally univentricular palliations. The treatment chosen is dependent on the preference of the institution, its experience, and also preference. Although survival following initial surgical intervention has improved significantly over the last 20 years, significant mortality and morbidity are present for both surgical strategies. As a result pediatric cardiologists continue to be challenged by discussions with families regarding initial decision

  15. Primary renal synovial sarcoma

    Directory of Open Access Journals (Sweden)

    Girish D. Bakhshi

    2012-03-01

    Full Text Available Primary Renal Sarcoma is rare tumor comprising only 1% of all renal tumours. Synovial sarcomas are generally deep-seated tumors arising in the proximity of large joints of adolescents and young adults and account for 5-10% of all soft tissue tumours. Primary synovial sarcoma of kidney is rare and has poor prognosis. It can only be diagnosed by immunohistochemistry. It should be considered as a differential in sarcomatoid and spindle cell tumours. We present a case of 33-year-old female, who underwent left sided radical nephrectomy for renal tumour. Histopathology and genetic analysis diagnosed it to be primary renal synovial sarcoma. Patient underwent radiation therapy and 2 years follow up is uneventful. A brief case report with review of literature is presented.

  16. Renal myxoma: a case report

    Directory of Open Access Journals (Sweden)

    Carlos Henrique C Souza

    2015-04-01

    Full Text Available Myxomas are rare tumors that can appear in many anatomical locations. There are only 14 cases of renal involvement documented in the literature. This article reports a case of renal myxoma in an elderly woman with recurrent cystitis. After five years of follow-up, the computed tomography (CT revealed a large solid tumor mass in the left kidney. Tumor resection was performed preserving the affected kidney with histopathological diagnosis of renal myxoma. The objective of this study is to report a rare case of renal myxoma, emphasizing the importance of the differential diagnosis from other benign and malignant mesenchymal tumors.

  17. Vascular Augmentation in Renal Transplantation: Supercharging and Turbocharging

    Directory of Open Access Journals (Sweden)

    Euicheol C. Jeong

    2017-05-01

    Full Text Available The most common anatomic variant seen in donor kidneys for renal transplantation is the presence of multiple renal arteries, which can cause an increased risk of complications. Accessory renal arteries should be anastomosed to the proper source arteries to improve renal perfusion via the appropriate vascular reconstruction techniques. In microsurgery, 2 kinds of vascular augmentation methods, known as ‘supercharging’ and ‘turbocharging,’ have been introduced to ensure vascular perfusion in the transferred flap. Supercharging uses a distant source of the vessels, while turbocharging uses vascular sources within the same flap territory. These technical concepts can also be applied in renal transplantation, and in this report, we describe 2 patients who underwent procedures using supercharging and turbocharging. In one case, the ipsilateral deep inferior epigastric artery was transposed to the accessory renal artery (supercharging, and in the other case, the accessory renal artery was anastomosed to the corresponding main renal artery with a vascular graft (turbocharging. The transplanted kidneys showed good perfusion and proper function. No cases of renal failure, hypertension, rejection, or urologic complications were observed. These microsurgical techniques can be safely utilized for renal transplantation with donor kidneys that have multiple arteries with a lower complication rate and better outcome.

  18. Vascular Augmentation in Renal Transplantation: Supercharging and Turbocharging.

    Science.gov (United States)

    Jeong, Euicheol C; Hwang, Seung Hwan; Eo, Su Rak

    2017-05-01

    The most common anatomic variant seen in donor kidneys for renal transplantation is the presence of multiple renal arteries, which can cause an increased risk of complications. Accessory renal arteries should be anastomosed to the proper source arteries to improve renal perfusion via the appropriate vascular reconstruction techniques. In microsurgery, 2 kinds of vascular augmentation methods, known as 'supercharging' and 'turbocharging,' have been introduced to ensure vascular perfusion in the transferred flap. Supercharging uses a distant source of the vessels, while turbocharging uses vascular sources within the same flap territory. These technical concepts can also be applied in renal transplantation, and in this report, we describe 2 patients who underwent procedures using supercharging and turbocharging. In one case, the ipsilateral deep inferior epigastric artery was transposed to the accessory renal artery (supercharging), and in the other case, the accessory renal artery was anastomosed to the corresponding main renal artery with a vascular graft (turbocharging). The transplanted kidneys showed good perfusion and proper function. No cases of renal failure, hypertension, rejection, or urologic complications were observed. These microsurgical techniques can be safely utilized for renal transplantation with donor kidneys that have multiple arteries with a lower complication rate and better outcome.

  19. Reverse ventilation--perfusion mismatch

    International Nuclear Information System (INIS)

    Palmaz, J.C.; Barnett, C.A.; Reich, S.B.; Krumpe, P.E.; Farrer, P.A.

    1984-01-01

    Patients having lobar airway obstruction or consolidation usually have decreases of both ventilation and perfusion on lung scans. We report three patients in whom hypoxic vasoconstriction was apparently incomplete, resulting in a ''reversed'' ventilation-perfusion mismatch. Perfusion of the hypoxic lobe on the radionuclide scan was associated with metabolic alkalosis, pulmonary venous and pulmonary arterial hypertension in these patients

  20. Arterial spin labelling in imaging of renal diseases and renal allograft pathology; MRT-Perfusionsmessung mit Arterial Spin Labelling. Anwendung fuer die Niere und Transplantatniere

    Energy Technology Data Exchange (ETDEWEB)

    Hueper, Katja; Gutberlet, Marcel [Medizinische Hochschule Hannover (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Kuehn, Bernd [Siemens AG/Siemens Healthcare GmbH, Erlangen (Germany)

    2016-06-15

    Arterial Spin Labelling (ASL) is a technique for non-invasive and contrast-free assessment of perfusion with MRI. Renal ASL allows examination of renal pathophysiology, evaluation of the course of renal disease and therapy effects by longitudinal measurements as well as characterization of renal tumors. In this article, techniques of ASL will be explained and challenges of renal ASL will be emphasized. In addition, examples for clinical application of ASL for diagnosis of renal disease and renal allograft pathology will be given.

  1. Hepatic artery perfusion imaging

    International Nuclear Information System (INIS)

    Thrall, J.H.; Gyves, J.W.; Ziessman, H.A.; Ensminger, W.D.

    1985-01-01

    Organ and region-selective intra-arterial chemotherapy have been used for more than two decades to treat malignant neoplasms in the extremities, head and neck region, pelvis, liver, and other areas. Substantial evidence of improved response to regional chemotherapy now exists, but there are stringent requirements for successful application of the regional technique. First, the chemotherapeutic agent employed must have appropriate pharmacokinetic and pharmacodynamic properties. Second, the drug must be reliably delivered to the tumor-bearing area. This typically requires an arteriographic assessment of the vascular supply of the tumor, followed by placement of a therapeutic catheter and confirmation that the ''watershed'' perfusion distribution from the catheter truly encompasses the tumor. Optimal catheter placement also minimizes perfusion of nontarget organs. Radionuclide perfusion imaging with technetium 99m-labeled particles, either microspheres or macroaggregates of albumin, has become the method of choice for making these assessments. Catheter placement itself is considered by many to represent a type of ''therapeutic'' intervention. However, once the catheter is in the hepatic artery the radionuclide perfusion technique can be used to assess adjunctive pharmacologic maneuvers designed to further exploit the regional approach to chemotherapy. This chapter presents the technetium Tc 99m macroaggregated albumin method for assessing catheter placement and the pharmacokinetic rationale for regional chemotherapy, and discusses two promising avenues for further intervention

  2. Extremity perfusion for sarcoma

    NARCIS (Netherlands)

    Hoekstra, Harald Joan

    2008-01-01

    For more than 50 years, the technique of extremity perfusion has been explored in the limb salvage treatment of local, recurrent, and multifocal sarcomas. The "discovery" of tumor necrosis factor-or. in combination with melphalan was a real breakthrough in the treatment of primarily irresectable

  3. Isolated limb perfusion.

    Science.gov (United States)

    Gillespie, Rosalyn; Chantier, Nariane

    1994-12-08

    Growing concern over the rising incidence of malignant melanoma has brought about a need for information on this disorder and the treatment available. Isolated limb perfusion is a relatively new technique used in only a few hospitals. An increased knowledge base will lead to a better understanding of the nursing care required and to a more in-depth care plan.

  4. A Simplified Whole-Organ CT Perfusion Technique with Biphasic Acquisition: Preliminary Investigation of Accuracy and Protocol Feasibility in Kidneys.

    Science.gov (United States)

    Yuan, XiaoDong; Zhang, Jing; Quan, ChangBin; Tian, Yuan; Li, Hong; Ao, GuoKun

    2016-04-01

    To determine the feasibility and accuracy of a protocol for calculating whole-organ renal perfusion (renal blood flow [RBF]) and regional perfusion on the basis of biphasic computed tomography (CT), with concurrent dynamic contrast material-enhanced (DCE) CT perfusion serving as the reference standard. This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Biphasic CT of the kidneys, including precontrast and arterial phase imaging, was integrated with a first-pass dynamic volume CT protocol and performed and analyzed in 23 patients suspected of having renal artery stenosis. The perfusion value derived from biphasic CT was calculated as CT number enhancement divided by the area under the arterial input function and compared with the DCE CT perfusion data by using the paired t test, correlation analysis, and Bland-Altman plots. Correlation analysis was made between the RBF and the extent of renal artery stenosis. All postprocessing was independently performed by two observers and then averaged as the final result. Mean ± standard deviation biphasic and DCE CT perfusion data for RBF were 425.62 mL/min ± 124.74 and 419.81 mL/min ± 121.13, respectively (P = .53), and for regional perfusion they were 271.15 mL/min per 100 mL ± 82.21 and 266.33 mL/min per 100 mL ± 74.40, respectively (P = .31). Good correlation and agreement were shown between biphasic and DCE CT perfusion for RBF (r = 0.93; ±10% variation from mean perfusion data [P < .001]) and for regional perfusion (r = 0.90; ±13% variation from mean perfusion data [P < .001]). The extent of renal artery stenosis was negatively correlated with RBF with biphasic CT perfusion (r = -0.81, P = .012). Biphasic CT perfusion is clinically feasible and provides perfusion data comparable to DCE CT perfusion data at both global and regional levels in the kidney. Online supplemental material is available for this article.

  5. Breast cancer metastatic to the kidney with renal vein involvement.

    Science.gov (United States)

    Nasu, Hatsuko; Miura, Katsutoshi; Baba, Megumi; Nagata, Masao; Yoshida, Masayuki; Ogura, Hiroyuki; Takehara, Yasuo; Sakahara, Harumi

    2015-02-01

    The common sites of breast cancer metastases include bones, lung, brain, and liver. Renal metastasis from the breast is rare. We report a case of breast cancer metastatic to the kidney with extension into the renal vein. A 40-year-old woman had undergone left mastectomy for breast cancer at the age of 38. A gastric tumor, which was later proved to be metastasis from breast cancer, was detected by endoscopy. Computed tomography performed for further examination of the gastric tumor revealed a large left renal tumor with extension into the left renal vein. It mimicked a primary renal tumor. Percutaneous biopsy of the renal tumor confirmed metastasis from breast cancer. Surgical intervention of the stomach and the kidney was avoided, and she was treated with systemic chemotherapy. Breast cancer metastatic to the kidney may present a solitary renal mass with extension into the renal vein, which mimics a primary renal tumor.

  6. Anionic and cationic drug secretion in the isolated perfused rat kidney after neonatal surgical induction of ureteric obstruction.

    NARCIS (Netherlands)

    Gier, R.P.E. de; Feitz, W.F.J.; Masereeuw, R.; Wouterse, A.C.; Smits, D.; Russel, F.G.M.

    2003-01-01

    OBJECTIVE: To study the pathophysiological changes of renal tubular drug transport mechanisms in congenital renal obstruction, by developing a model for perfusing the isolated kidney (IPK) after neonatal surgical induction of partial ureteric obstruction in Hanover Wistar rats. MATERIAL AND METHODS:

  7. Brain SPECT perfusion in children and adolescents poly drug abusers

    International Nuclear Information System (INIS)

    Ramos, R.R.N.; Etchebehere, E.C.S.C.; Santos, A.O.; Lima, M.C.L.; Ramos, C.D.; Camargo, E.E.; Silva, C.A.M.; Serrat, S.M.

    2002-01-01

    Polydrug abuse in children and adolescents is a major social problem. Aim: The aim of this study was to evaluate brain perfusion in polydrug abuser adolescents with brain SPECT imaging (BSI) using 99m Tc-HMPAO. Materials and Methods: Sixteen male polydrug abuser patients (11 to 18 years) were submitted to BSI. Forty-eight normal individuals (26 males, 22 females; 18 to 31 years) were used as a control group. Images were performed after an intravenous injection of 99m Tc-HMPAO in a dark, quiet room. Images were acquired in a camera-computer system equipped with a fan beam collimator. The images were reconstructed in the transaxial, coronal and sagittal views and submitted to semi-quantitative analysis using the thalami as reference, by placing regions of interest (ROIs) in the cerebral and cerebellar cortices. Patients were also submitted to neuropsychology tests and neurologic examination. Results: Significant hypoperfusion was found in the inferior portion of the frontal lobes (left and right: p<0.0001), temporal lobes (left lateral: p=0.0392; right lateral: p=0.0044; left and right mesial: p<0.0005), right parietal lobe (p=0.025), visual cortex (p=0.0013), pons (p = 0.0002), cerebellar hemispheres (left: p=0.0216; right: p=0.0005) and vermis (p=0.0015). An inverse relationship was observed between the degree of perfusion and the duration of drug abuse in the inferior left frontal lobe (? = -0.55; p=0.0255), superior right frontal lobe (? = -0.51; p=0.043), lateral right temporal lobe (? = -0.58; p=0.0172), mesial left temporal lobe (? -0.52; p=0.0384), left parietal lobe (? = -0.51; p=0.0416), basal ganglia (left: ? = -0.70; p=0.0022; right: ? = -0.65; p=0.0056) and cingulate gyrus (? = -0.66; p=0.0054). A significant correlation was observed between the perfusion of the temporal lobes with the Bender-Koppits test (left and right lateral: p=0.0559). Significant correlation was also noted between the perfusion of the lateral left temporal lobe (p=0.0559), parietal

  8. The role of preservation solution on acid-base regulation during machine perfusion of kidneys.

    Science.gov (United States)

    Baicu, Simona C; Taylor, Michael J; Brockbank, Kelvin G M

    2006-01-01

    To meet the current clinical organ demand, efficient preservation methods and solutions are needed to increase the number of viable kidneys for transplantation. In the present study, the influence of perfusion solution buffering strength on renal pH dynamics and regulation mechanisms during kidney ex vivo preservation was determined. Porcine kidneys were hypothermically machine perfused for 72 h with either Unisol-UHK or Belzer-Machine Perfusion solution, Belzer-MP solution. Renal perfusate samples were periodically collected and biochemically analyzed. The UHK solution, a Hepes-based solution (35 mM), provided a more efficient control of renal pH that, in turn, resulted in minor changes in the perfusate pH relative to baseline, in response to tissue CO2 and HCO3- production. In the perfusate of Belzer-MP kidney group a wider range of pH values were recorded and a pronounced pH reduction was seen in response to significant rises in pCO2 and HCO3- concentrations. The Belzer-MP solution, containing phosphate (25 mM) as its main buffer, and only 10 mM Hepes, had a greater buffering requirement to attenuate larger pH changes.

  9. Simultaneous measurement of pO2 and perfusion in the rabbit kidney in vivo.

    Science.gov (United States)

    O'Connor, Paul M; Anderson, Warwick P; Kett, Michelle M; Evans, Roger G

    2007-01-01

    Recently, a combined probe has been developed capable of simultaneous measurement of local tissue pO2 (fluorescence oximetry) and microvascular perfusion (laser Doppler flux) within the same local region. The aim of the current study was to test the utility of these combined probes to measure pO2 and perfusion in the kidney. Studies were performed in anesthetized, artificially ventilated rabbits (n=7). Baseline measurements of renal medullary perfusion and pO2 obtained using combined probes (537 +/- 110 units & 28.7 +/- 6.l mmHg, respectively) were indistinguishable from those obtained using independent probes (435 +/- 102 units & 26.9 +/- 6.4 mmHg). Baseline measurements of renal cortical pO2 were also similar between combined (9.7 +/- 1.6 mmHg) and independent probes (9.5 +/- 2.3 mmHg). Baseline levels of cortical perfusion however, were significantly greater when measured using independent probes (1130 +/- 114 units) compared to combined probes (622 +/- 59 units; P pO2 resulting from graded stimulation of the renal nerves were not significantly different when measured using combined probes to those obtained using independent probes. We conclude that combined probes are equally suitable to independent probes for tissue pO2 and microvascular perfusion measurement in the kidney. Our results raise some concerns regarding the accuracy of these OxyLite fluorescence probes for pO2 measurement in the kidney, particularly within the renal cortex.

  10. Renal Osteodystrophy

    Directory of Open Access Journals (Sweden)

    Aynur Metin Terzibaşoğlu

    2004-12-01

    Full Text Available Chronic renal insufficiency is a functional definition which is characterized by irreversible and progressive decreasing in renal functions. This impairment is in collaboration with glomeruler filtration rate and serum creatinine levels. Besides this, different grades of bone metabolism disorders develop in chronic renal insufficiency. Pathologic changes in bone tissue due to loss of renal paranchyme is interrelated with calcium, phosphorus vitamine-D and parathyroid hormone. Clinically we can see high turnover bone disease, low turnover bone disease, osteomalacia, osteosclerosis and osteoporosis in renal osteodystropy. In this article we aimed to review pathology of bone metabolism disorders due to chronic renal insufficiency, clinic aspects and treatment approaches briefly.

  11. Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure.

    Science.gov (United States)

    Sammut, Eva; Zarinabad, Niloufar; Wesolowski, Roman; Morton, Geraint; Chen, Zhong; Sohal, Manav; Carr-White, Gerry; Razavi, Reza; Chiribiri, Amedeo

    2015-02-12

    Cardiac magnetic resonance (CMR) is playing an expanding role in the assessment of patients with heart failure (HF). The assessment of myocardial perfusion status in HF can be challenging due to left ventricular (LV) remodelling and wall thinning, coexistent scar and respiratory artefacts. The aim of this study was to assess the feasibility of quantitative CMR myocardial perfusion analysis in patients with HF. A group of 58 patients with heart failure (HF; left ventricular ejection fraction, LVEF ≤ 50%) and 33 patients with normal LVEF (LVEF >50%), referred for suspected coronary artery disease, were studied. All subjects underwent quantitative first-pass stress perfusion imaging using adenosine according to standard acquisition protocols. The feasibility of quantitative perfusion analysis was then assessed using high-resolution, 3 T kt perfusion and voxel-wise Fermi deconvolution. 30/58 (52%) subjects in the HF group had underlying ischaemic aetiology. Perfusion abnormalities were seen amongst patients with ischaemic HF and patients with normal LV function. No regional perfusion defect was observed in the non-ischaemic HF group. Good agreement was found between visual and quantitative analysis across all groups. Absolute stress perfusion rate, myocardial perfusion reserve (MPR) and endocardial-epicardial MPR ratio identified areas with abnormal perfusion in the ischaemic HF group (p = 0.02; p = 0.04; p = 0.02, respectively). In the Normal LV group, MPR and endocardial-epicardial MPR ratio were able to distinguish between normal and abnormal segments (p = 0.04; p = 0.02 respectively). No significant differences of absolute stress perfusion rate or MPR were observed comparing visually normal segments amongst groups. Our results demonstrate the feasibility of high-resolution voxel-wise perfusion assessment in patients with HF.

  12. Digital subtraction angiography in 105 living renal transplant donors

    International Nuclear Information System (INIS)

    Suh, Ho Jong; Oh, Kyung Seung; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duck

    1989-01-01

    In order to analyze the number and length of the renal arteries and to evaluate abnormalities of the renal parenchyma and vessel, digital subtraction angiogram images of 105 potential renal donors (45 men and 60 women aged 17-66 years) were studied retrospectively. For the entire series, 31 donors had multiple renal arteries on one side (15 on the left, 11 on the right) and 5 donors on the both sides. 89 donors were family related either parents or siblings of recipients. The estimation of the length of the renal artery was based on the mean height of the second lumbar vertebral body (L2). The right renal artery is significant longer than on the left and measured more than the height of L2 vertebral body in 84 cases on the right and 60 cases on the left. Twenty two donors underwent right nephrectomy due to presence of multiple renal arteries on the left (N=14), proximal bifurcation of left main renal artery (N=3), and young females in reproductive age (N=5). Unexpected abnormalities found with angiogram were seen in 7 cases and they include renal artery stenosis (N=2), renal cysts (N=4) and focal infarction (N=1). In cases of the renal cysts and focal infarction, there were no serious complications related to the abnormalities. It is conclude that intra-arterial digital subtraction angiography is safe and efficient method to image renal anatomy of the potential renal donors

  13. Job analysis and student assessment tool: perfusion education clinical preceptor.

    Science.gov (United States)

    Riley, Jeffrey B

    2007-09-01

    The perfusion education system centers on the cardiac surgery operating room and the perfusionist teacher who serves as a preceptor for the perfusion student. One method to improve the quality of perfusion education is to create a valid method for perfusion students to give feedback to clinical teachers. The preceptor job analysis consisted of a literature review and interviews with preceptors to list their critical tasks, critical incidents, and cognitive and behavioral competencies. Behaviorally anchored rating traits associated with the preceptors' tasks were identified. Students voted to validate the instrument items. The perfusion instructor rating instrument with a 0-4, "very weak" to "very strong" Likert rating scale was used. The five preceptor traits for student evaluation of clinical instruction (SECI) are as follows: The clinical instructor (1) encourages self-learning, (2) encourages clinical reasoning, (3) meets student's learning needs, (4) gives continuous feedback, and (5) represents a good role model. Scores from 430 student-preceptor relationships for 28 students rotating at 24 affiliate institutions with 134 clinical instructors were evaluated. The mean overall good preceptor average (GPA) was 3.45 +/- 0.76 and was skewed to the left, ranging from 0.0 to 4.0 (median = 3.8). Only 21 of the SECI relationships earned a GPA SECI are methods to provide valid information to improve the quality of a perfusion education program.

  14. Myocardial perfusion SPECT imaging in patients with myocardial bridging

    International Nuclear Information System (INIS)

    Fang Wei; Qiu Hong; Yang Weixian; Wang Feng; He Zuoxiang

    2008-01-01

    Objective: Stress myocardial perfusion SPECT imaging was used to assess myocardial ischemia in patients with myocardial bridging. Methods: Ninety-six patients with myocardial bridging of the left anterior descending artery documented by coronary angiography were included in this study. All under- went exercise or pharmacological stress myocardial perfusion SPECT assessing myocardial ischemia. None had prior myocardial infarction. One year follow-up by telephone interview was performed in all patients. Results The mean stenotic severity of systolic phase on angiography was (65 ± 19)%. In the SPECT study, 20 of 96 (20.8%) patients showed abnormal perfusion. This percentage was significantly higher than that of stress electrocardiogram (ECG). The higher positive rate of SPECT perfusion images was showed in the group of patients with severe systolic narrowing (≥75%) than that with mild-to-moderate systolic narrowing (50% vs 6.3%, P<0.001). The prevalence of abnormal image was significantly higher in ELDERLY PEOPLE; patients with STT change on rest ECG than in those with normal rest ECG (54.2% vs 9.7%, P<0.001). During follow-up, one patient with abnormal SPECT perfusion image sustained angina and accepted percutaneous coronary intervention, and no cardiac event occurred in patients with normal images. Conclusions: Stress myocardial perfusion SPECT imaging can be used effectively for assessing myocardial ischemia and has potential prognostic value for patients with myocardial bridging. (authors)

  15. Renal blood flow and oxygenation drive nephron progenitor differentiation.

    Science.gov (United States)

    Rymer, Christopher; Paredes, Jose; Halt, Kimmo; Schaefer, Caitlin; Wiersch, John; Zhang, Guangfeng; Potoka, Douglas; Vainio, Seppo; Gittes, George K; Bates, Carlton M; Sims-Lucas, Sunder

    2014-08-01

    During kidney development, the vasculature develops via both angiogenesis (branching from major vessels) and vasculogenesis (de novo vessel formation). The formation and perfusion of renal blood vessels are vastly understudied. In the present study, we investigated the regulatory role of renal blood flow and O2 concentration on nephron progenitor differentiation during ontogeny. To elucidate the presence of blood flow, ultrasound-guided intracardiac microinjection was performed, and FITC-tagged tomato lectin was perfused through the embryo. Kidneys were costained for the vasculature, ureteric epithelium, nephron progenitors, and nephron structures. We also analyzed nephron differentiation in normoxia compared with hypoxia. At embryonic day 13.5 (E13.5), the major vascular branches were perfused; however, smaller-caliber peripheral vessels remained unperfused. By E15.5, peripheral vessels started to be perfused as well as glomeruli. While the interior kidney vessels were perfused, the peripheral vessels (nephrogenic zone) remained unperfused. Directly adjacent and internal to the nephrogenic zone, we found differentiated nephron structures surrounded and infiltrated by perfused vessels. Furthermore, we determined that at low O2 concentration, little nephron progenitor differentiation was observed; at higher O2 concentrations, more differentiation of the nephron progenitors was induced. The formation of the developing renal vessels occurs before the onset of blood flow. Furthermore, renal blood flow and oxygenation are critical for nephron progenitor differentiation. Copyright © 2014 the American Physiological Society.

  16. Renal venogram

    Science.gov (United States)

    ... be black. Other structures will be shades of gray. Veins are not normally seen in an x- ... Venogram - kidney; Renal vein thrombosis - venogram Images Kidney anatomy Kidney - blood and urine flow Renal veins References ...

  17. Ventilation-perfusion lung imaging in diaphragmatic paralysis

    International Nuclear Information System (INIS)

    Chopra, S.K.; Taplin, G.V.

    1977-01-01

    Clinical, radiological, physiological, and lung imaging findings from a patient with paralysis of the diaphragm are described. Dyspnea, hypoxemia and hypercapnia increased when the patient changed from the upright to the supine positions. Ventilation (V) and perfusion (P) images of the right lung appeared to be relatively normal and remained nearly the same in the upright and supine positions. In contrast, V/P images of the left lung were smaller than those of the right lung in the upright position and decreased further in the supine position. In addition, the size of the ventilation image was much smaller than that of the perfusion

  18. Mature Cystic Renal Teratoma

    International Nuclear Information System (INIS)

    Yavuz, Alpaslan; Ceken, Kagan; Alimoglu, Emel; Akkaya, Bahar

    2014-01-01

    Teratomas are rare germline tumors that originate from one or more embryonic germ cell layers. Teratoma of the kidney is extremely rare, and less than 30 cases of primary intrarenal teratomas have been published to date. We report the main radiologic features of an unusual case of mature cystic teratoma arising from the left kidney in a two-year-old boy. A left-sided abdominal mass was detected on physical examination and B-Mod Ultrasound (US) examination revealed a heterogeneous mass with central cystic component. Computed tomography (CT) demonstrated a lobulated, heterogeneous, hypodense mass extending craniocaudally from the splenic hilum to the level of the left iliac fossa. Nephrectomy was performed and a large, fatty mass arising from the left kidney was excised. The final pathologic diagnosis was confirmed as cystic renal teratoma

  19. Perfusion based cell culture chips

    DEFF Research Database (Denmark)

    Heiskanen, Arto; Emnéus, Jenny; Dufva, Martin

    2010-01-01

    Performing cell culture in miniaturized perfusion chambers gives possibilities to experiment with cells under near in vivo like conditions. In contrast to traditional batch cultures, miniaturized perfusion systems provide precise control of medium composition, long term unattended cultures...... and tissue like structuring of the cultures. However, as this chapter illustrates, many issues remain to be identified regarding perfusion cell culture such as design, material choice and how to use these systems before they will be widespread amongst biomedical researchers....

  20. Renal transplant scintigraphy (Part 1)

    International Nuclear Information System (INIS)

    Chew, Ghee

    2005-01-01

    Renal transplantation is the most effective mode of renal replacement therapy for correction of renal failure. Renal donors can either be: a. a deceased person - the kidneys being removed when brain death or absence of cerebral cortical function / perfusion is confirmed - the cadaveric kidney is packed in ice and nutrient solution and transplanted within 24 hours of removal ('cold ischemia') ob. a living donor - the donor may or may not be related to the recipient. Due to the limited length of the renal vessels and ureter of the donor kidney, it is implanted close to the bladder of the recipient. The donor vessels are anastomosed to the iliac artery and vein of the recipient. Transplant variants: a. 2 kidneys maybe transplanted because: - an old donor with less kidney reserve from atrophy due to age or disease (e.g. hypertension) - an infant donor when both kidneys are removed en bloc, b. Donor kidneys with more than 1 artery, vein or ureter. c. Donor horse shoe kidney d. Combined renal and pancreas transplant for type I diabetics -a short segment of duodenum transplanted with the pancreas maybe implanted into the bladder. Copyright (2005) The Australian and New Zealand Society of Nuclear Medicine

  1. Isolated Left Pulmonary Artery Agenesis: A Case Report

    Directory of Open Access Journals (Sweden)

    Tansel Ansal Balcı

    2012-08-01

    Full Text Available Unilateral pulmonary artery agenesis without any cardiovascular malformation is a rare anomaly. We present the imaging findings of a patient who was diagnosed as isolated left pulmonary artery agenesis. A 27-year-old female patient was admitted to our hospital due to dyspnea during exercise for five years. Chest X-ray revealed minimally small left pulmonary hilum and left lung. She was admitted to our clinic with the suspicion of pulmonary artery pathology. Absent perfusion of the left lung with normal ventilation was visualized on scintigraphy. MDCT angiography of pulmonary arteries showed absent left main pulmonary artery with systemic collaterals around left hemithorax. Pulmonary artery agenesis can be asymptomatic and isolated until adulthood. Both scintigraphy and CT angiography images of pulmonary artery agenesis of a patient are rare in the literature. Pulmonary ventilation- perfusion scintigraphy can be used not only for pulmonary embolism but also pathologies involving pulmonary artery and its branches. (MIRT 2012;21:80-83

  2. Attenuated renal and intestinal injury after use of a mini-cardiopulmonary bypass system

    NARCIS (Netherlands)

    Huybregts, Rien A. J. M.; Morariu, Aurora M.; Rakhorst, Gerhard; Spiegelenberg, Stefan R.; Romijn, Hans W. A.; de Vroege, Roel; van Oeveren, Willem

    Background. Transient, subclinical myocardial, renal, intestinal, and hepatic tissue injury and impaired homeostasis is detectable even in low-risk patients undergoing conventional cardiopulmonary bypass (CPB). Small extracorporeal closed circuits with low priming volumes and optimized perfusion

  3. The value of quantitative methods for assessment of renal transplant and comparison with physician expertness

    International Nuclear Information System (INIS)

    Firouzi, F.; Fazeli, M.

    2002-01-01

    Radionuclide renal diagnostic studies play an important role in assessing renal allograft. Various quantitative parameters have been derived from the Radionuclide renogram to facilitate and confirm the changes in perfusion and/or function of kidney allograft. These quantitative methods were divided into parameters used for assessing renal graft perfusion and parameters used for evaluating parenchymal function. The blood flow in renal transplants can be quantified by measuring the rate of activity appearance in the kidney graft and the ratio of the integral activity under the transplanted kidney and arterial curves e.g. Hilton's perfusion index and Karachi's kidney/aortic ratio. Quantitative evaluation of graft extraction and excretion was assessed by parameters derived from 123 I/ 131 I-OH, 99 mTc-DTPA or 99 mTc-Mag renogram. In this study we review retrospectively renal transplanted patients scintigraphies that all of them under gone to renal allograft needle biopsy nearly to date of allograft scan. We performed quantitative methods for all patients. We observed perfusion parameters affected by quality of bolus injection and numerical aviations related to changes in the site and size of region of interest. Quantitative methods for renal parenchymal functions were nonspecific and far from defining a specific cause of graft dysfunction. In conclusion, neither perfusion nor parenchymal parameters have not enough diagnostic power for specific diagnosis of graft dysfunction. Physician expertness by using scintigraphic images and renogram curves is more sensitive and specific for diagnosis of renal allograft dysfunction

  4. The incidence and functional consequences of RT-associated cardiac perfusion defects

    International Nuclear Information System (INIS)

    Marks, Lawrence B.; Yu Xiaoli; Prosnitz, Robert G.; Zhou Sumin; Hardenbergh, Patricia H.; Blazing, Michael; Hollis, Donna; Lind, Pehr; Tisch, Andrea; Wong, Terence Z.; Borges-Neto, Salvador

    2005-01-01

    Purpose: Radiation therapy (RT) for left-sided breast cancer has been associated with cardiac dysfunction. We herein assess the temporal nature and volume dependence of RT-induced left ventricular perfusion defects and whether these perfusion defects are related to changes in cardiac wall motion or alterations in ejection fraction. Methods: From 1998 to 2001, 114 patients were enrolled onto an IRB-approved prospective clinical study to assess changes in regional and global cardiac function after RT for left-sided breast cancer. Patients were imaged 30 to 60 minutes after injection of technetium 99m sestamibi or tetrofosmin. Post-RT perfusion scans were compared with the pre-RT studies to assess for RT-induced perfusion defects as well as functional changes in wall motion and ejection fraction. Two-tailed Fisher's exact test and the Cochran-Armitage test for linear trends were used for statistical analysis. Results: The incidence of new perfusion defects 6, 12, 18, and 24 months after RT was 27%, 29%, 38%, and 42%, respectively. New defects occurred in approximately 10% to 20% and 50% to 60% of patients with less than 5%, and greater than 5%, of their left ventricle included within the RT fields, respectively (p = 0.33 to 0.00008). The rates of wall motion abnormalities in patients with and without perfusion defects were 12% to 40% versus 0% to 9%, respectively; p values were 0.007 to 0.16, depending on the post-RT interval. Conclusions: Radiation therapy causes volume-dependent perfusion defects in approximately 40% of patients within 2 years of RT. These perfusion defects are associated with corresponding wall-motion abnormalities. Additional study is necessary to better define the long-term functional consequences of RT-induced perfusion defects

  5. Impairment of myocardial perfusion in children with sickle cell disease; Alteration de la perfusion myocardique chez l'enfant drepanocytaire

    Energy Technology Data Exchange (ETDEWEB)

    Maunoury, C. [Hopital Necker-Enfants-Malades, Service de Medecine Nucleaire, 75 - Paris (France); Acar, P. [Centre Hospitalier Universitaire, Hopital des Enfants, Service de Cardiologie Pediatrique, 31 - Toulouse (France); Montalembert, M. de [Hopital Necker-Enfants-Malades, Service de Pediatrie Generale, 75 - Paris (France)

    2003-10-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 {+-} 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 {+-} 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  6. The 64-MSCT study of relationship between renal corticomedullary differentiation, contrast between renal cortex and medulla, renal cortex and medulla CT peak value with the single renal function in hydronephrotic kidney

    International Nuclear Information System (INIS)

    Wang Yunhua; Hou Weiwei; Liu Ruihong; He Jianjun; Zhi Ke

    2009-01-01

    Objective: To study 64-MSCT perfusion imaging features about renal corticomedullary differentiation, contrast between renal cortex and medulla (CMC), renal cortex and medulla CT peak value in normal and hydronephrotic kidneys, and to explore the relationship between them and the unilateral renal function. Methods: Thirty-six patients with obstructive nephrohydrosis underwent 64-MSCT perfusion scanning. The split renal glomerular filtration rates (GFR) of their kidneys were measured by SPECT renal dynamic imaging. The 72 kidneys were divided into groups of normal renal function group, mild and severe renal impairment groups according to GFR. Renal corticomedullary differentiation on CT images was graded as clear, obscure, part clear. The CT intensity of cortex and medulla was measured in order to calculate contrast between renal cortex and medulla (CMC). Using Pearson correlation test, the correlation between them and renal GFR were examined. Results: (1) In the 24 kidneys of normal group, all kidneys showed clear CMD. In the 21 kidneys of mild renal impairment group, 14 kidneys showed clear CMD, 2 showed obscure CMD and 5 showed part clear of CMD. In the 27 kidneys of severe renal impairment group, 7 kidneys showed clear CMD, 5 showed obscure CMD and 15 showed part clear of CMD. (2)The CMC of normal group was 0.62 ± 0.20, while it was 0.52 ± 0.14 and 0.37 ± 0.11 for mild renal impairment group and severe renal impairment group CMC respectively. The CMC had positive linear correlation with GFR (r=0.536,P<0.05). (3) The renal cortex and medulla CT peak value of normal group were (133 ± 22) and (104 ± 16) HU; The renal cortex and medulla CT peak value of mild renal impairment group were (91 ± 29) and (76 ± 25) HU; The renal cortex and medulla CT peak value of severe renal impairment group were (68 ± 24) and (57 ± 21) HU(F=42.76 and 32.68,P<0.05). The renal cortex and medulla CT peak value had positive linear correlation with GFR (r=0.672 and 0.623, P<0

  7. Unilateral absence of lung perfusion resulting from endarteritis of the pulmonary artery

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Turini, T.L.

    This case shows endarteritis of left pulmonary artery in the angiographic study with absent perfusion of the left lung in the MAA 131 I scintigraphy. Considerations are made conderning the presumable diagnosis of infection by 'toxocara canis' larval form. The literature review don't point out a similar case. (author) [pt

  8. Gammagraphy of cerebral perfusion

    International Nuclear Information System (INIS)

    Vazquez, Silvia

    2003-01-01

    Important aspects of the gammagraphy of cerebral perfusion and the diverse clinical applications in the neurological diseases are comment in this article. We focus in the usefulness of the photon emission cerebral tomography (SPECT) and its capacity to cross the hemato encephalic barrier through the use of radiopharmacons like 99 mTc-H M-PAO and 99mTc-EDC, thus managing to offer functional data on the captantes neurons of the radiopharmacon. The clinical applications of SPECT are studied; cerebrovascular disease, transient ischemic attacks, dementias, Alzheimer disease, as well as other neurological diseases are referred. (The author)

  9. Albumin uptake by renal lymphatics with and without obstruction of the renal vein

    International Nuclear Information System (INIS)

    Threefoot, S.A.; Pearson, J.E. Jr.; Georgiardis, A.

    1989-01-01

    Experiments involving injection of radio-iodinated albumin into the left renal arteries or left ureters of dogs indicate that the renal lymphatics are capable of a major contribution in returning to the circulation albumin (or other large molecules) escaping from renal capillaries. I-131-albumin was injected into the jugular vein of controls or into the left renal artery or in retrograde manner into the left ureter of female dogs. Experimental groups included those with no obstruction, occlusion of left renal veins or left renal lymphatics, or both. Collections were made from the right femoral artery, both renal veins, thoracic duct and both ureters at frequent intervals for 2 to 4 hours. Data analysis included I-131 concentration, specific activity, rate of recovery and selected ratios. After renal arterial injection, the percentage of I131 recovered in thoracic duct lymph of dogs without renal venous obstruction was 5 to 10 times that recovered in those that received injections into the jugular vein. In dogs with renal venous obstruction, recovery from the thoracic duct was 10 to 1,000 times that in control dogs. Most of the differences occurred during the first hour, after which time as recirculation and redistribution occurred the rates of appearance in thoracic duct lymph in each group were similar. The differences in the ratios of concentration in thoracic duct lymph to concentration in femoral arterial blood were also much greater when the renal vein was obstructed than in dogs with no obstruction. The greater return of albumin through the thoracic duct in those with impeded renal venous outflow was probably related to both sequestered concentration and increased intrarenal pressure

  10. Risk factors for acute renal failure: inherent and modifiable risks.

    Science.gov (United States)

    Leblanc, Martine; Kellum, John A; Gibney, R T Noel; Lieberthal, Wilfred; Tumlin, James; Mehta, Ravindra

    2005-12-01

    Our purpose is to discuss established risk factors in the development of acute renal failure and briefly overview clinical markers and preventive measures. Findings from the literature support the role of older age, diabetes, underlying renal insufficiency, and heart failure as predisposing factors for acute renal failure. Diabetics with baseline renal insufficiency represent the highest risk subgroup. An association between sepsis, hypovolemia, and acute renal failure is clear. Liver failure, rhabdomyolysis, and open-heart surgery (especially valve replacement) are clinical conditions potentially leading to acute renal failure. Increasing evidence shows that intraabdominal hypertension may contribute to the development of acute renal failure. Radiocontrast and antimicrobial agents are the most common causes of nephrotoxic acute renal failure. In terms of prevention, avoiding nephrotoxins when possible is certainly desirable; fluid therapy is an effective prevention measure in certain clinical circumstances. Supporting cardiac output, mean arterial pressure, and renal perfusion pressure are indicated to reduce the risk for acute renal failure. Nonionic, isoosmolar intravenous contrast should be used in high-risk patients. Although urine output and serum creatinine lack sensitivity and specificity in acute renal failure, they remain the most used parameters in clinical practice. There are identified risk factors of acute renal failure. Because acute renal failure is associated with a worsening outcome, particularly if occurring in critical illness and if severe enough to require renal replacement therapy, preventive measures should be part of appropriate management.

  11. Giant kidney worms in a patient with renal cell carcinoma.

    Science.gov (United States)

    Kuehn, Jemima; Lombardo, Lindsay; Janda, William M; Hollowell, Courtney M P

    2016-03-07

    Dioctophyma renale (D. renale), or giant kidney worms, are the largest nematodes that infect mammals. Approximately 20 cases of human infection have been reported. We present a case of a 71-year-old man with a recent history of unintentional weight loss and painless haematuria, passing elongated erythematous tissue via his urethra. CT revealed a left renal mass with pulmonary nodules and hepatic lesions. On microscopy, the erythematous tissue passed was identified as D. renale. On subsequent renal biopsy, pathology was consistent with renal cell carcinoma. This is the first reported case of concomitant D. renale infection and renal cell carcinoma, and the second reported case of D. renale infection of the left kidney alone. 2016 BMJ Publishing Group Ltd.

  12. Anatomic Patterns of Renal Arterial Sympathetic Innervation: New Aspects for Renal Denervation.

    Science.gov (United States)

    Imnadze, Guram; Balzer, Stefan; Meyer, Baerbel; Neumann, Joerg; Krech, Rainer Horst; Thale, Joachim; Franz, Norbert; Warnecke, Henning; Awad, Khaled; Hayek, Salim S; Devireddy, Chandan

    2016-12-01

    Initial studies of catheter-based renal arterial sympathetic denervation to lower blood pressure in resistant hypertensive patients renewed interest in the sympathetic nervous system's role in the pathogenesis of hypertension. However, the SYMPLICITY HTN-3 study failed to meet its prespecified blood pressure lowering efficacy endpoint. To date, only a limited number of studies have described the microanatomy of renal nerves, of which, only two involve humans. Renal arteries were harvested from 15 cadavers from the Klinikum Osnabruck and Schuchtermann Klinik, Bad Rothenfelde. Each artery was divided longitudinally in equal thirds (proximal, middle, and distal), with each section then divided into equal superior, inferior, anterior, and posterior quadrants, which were then stained. Segments containing no renal nerves were given a score value = 0, 1-2 nerves with diameter 4 nerves or nerve diameter ≥600 µm a score = 3. A total of 22 renal arteries (9 right-sided, 13 left-sided) were suitable for examination. Overall, 691 sections of 5 mm thickness were prepared. Right renal arteries had significantly higher mean innervation grade (1.56 ± 0.85) compared to left renal arteries (1.09 ± 0.87) (P renal artery has significantly higher innervation scores than the left. The anterior and superior quadrants of the renal arteries scored higher in innervation than the posterior and inferior quadrants did. The distal third of the renal arteries are more innervated than the more proximal segments. These findings warrant further evaluation of the spatial innervation patterns of the renal artery in order to understand how it may enhance catheter-based renal arterial denervation procedural strategy and outcomes. The SYMPLICITY HTN-3 study dealt a blow to the idea of the catheter-based renal arterial sympathetic denervation. We investigated the location and patterns of periarterial renal nerves in cadaveric human renal arteries. To quantify the density of the

  13. Trigeminal perineural spread of renal cell carcinoma

    International Nuclear Information System (INIS)

    Hornik, Alejandro; Rosenblum, Jordan; Biller, Jose

    2012-01-01

    A 55-year-old man had a five-day history of “pins and needles” sensation on the left chin. Examination showed decreased pinprick sensation on the territory of the left mandibular branch of the trigeminal nerve. Brain magnetic resonance imaging (MRI) with gadolinium showed enhancement involving the left mandibular branch. Computed tomography (CT) of the chest, abdomen, and pelvis showed a left kidney mass diagnosed as renal carcinoma following nephrectomy. The “numb-chin” syndrome heralds or accompanies systemic malignancies. Trigeminal perineural spread has been well-documented in head and neck neoplasms, however, to our knowledge, it has not been reported in renal neoplasms. (author)

  14. Relation of Renal Function with Left Ventricular Systolic Function and NT-proBNP Level and Its Prognostic Implication in Heart Failure with Preserved versus Reduced Ejection Fraction: an analysis from the Korean Heart Failure (KorHF) Registry.

    Science.gov (United States)

    Park, Chan Soon; Park, Jin Joo; Oh, Il-Young; Yoon, Chang-Hwan; Choi, Dong-Ju; Park, Hyun-Ah; Kang, Seok-Min; Yoo, Byung-Su; Jeon, Eun-Seok; Kim, Jae-Joong; Cho, Myeong-Chan; Chae, Shung Chull; Ryu, Kyu-Hyung; Oh, Byung-Hee

    2017-09-01

    The relationship between ejection fraction (EF), N-terminal pro-brain natriuretic peptide (NT-proBNP) levels and renal function is unknown as stratified by heart failure (HF) type. We investigated their relation and the prognostic value of renal function in heart failure with preserved ejection fraction (HFpEF) vs. reduced ejection fraction (HFrEF). NT-proBNP, glomerular filtration rate (GFR), and EF were obtained in 1,932 acute heart failure (AHF) patients. HFrEF was defined as EFrenal dysfunction as GFRrenal dysfunction: 30≤GFRrenal dysfunction: GFRrenal dysfunction did not differ between HFpEF and HFrEF (49% vs. 52%, p=0.210). Patients with renal dysfunction had higher 12-month mortality in both HFpEF (7.9% vs. 15.2%, log-rank p=0.008) and HFrEF (8.6% vs. 16.8%, log-rank prenal dysfunction was an independent predictor of 12-month mortality (hazard ratio [HR], 2.08; 95% confidence interval [CI], 1.40-3.11). When stratified according to EF: the prognostic value of severe renal dysfunction was attenuated in HFpEF patients (HR, 1.46; 95% CI, 0.66-3.21) contrary to HFrEF patients (HR, 2.43; 95% CI, 1.52-3.89). In AHF patients, the prevalence of renal dysfunction did not differ between HFpEF and HFrEF patients. However, the prognostic value of renal dysfunction was attenuated in HFpEF patients.

  15. MRI to assess renal structure and function.

    Science.gov (United States)

    Artunc, Ferruh; Rossi, Cristina; Boss, Andreas

    2011-11-01

    In addition to excellent anatomical depiction, MRI techniques have expanded to study functional aspects of renal physiology, such as renal perfusion, glomerular filtration rate (GFR) or tissue oxygenation. This review will focus on current developments with an emphasis on clinical applicability. The method of GFR determination is largely heterogeneous and still has weaknesses. However, the technique of employing liver disappearance curves has been shown to be accurate in healthy persons and patients with chronic kidney disease. In potential kidney donors, complete evaluation of kidney anatomy and function can be accomplished in a single-stop investigation. Techniques without contrast media can be utilized to measure renal tissue oxygenation (blood oxygen level-dependent MRI) or perfusion (arterial spin labeling) and could aid in the diagnosis and treatment of ischemic renal diseases, such as renal artery stenosis. Diffusion imaging techniques may provide information on spatially restricted water diffusion and tumor cellularity. Functional MRI opens new horizons in studying renal physiology and pathophysiology in vivo. Although extensively utilized in research, labor-intensive postprocessing and lack of standardization currently limit the clinical applicability of functional MRI. Further studies are necessary to evaluate the clinical value of functional magnetic resonance techniques for early discovery and characterization of kidney disease.

  16. Perfusion of tumor-bearing kidneys as a model for scintigraphic screening of monoclonal antibodies

    International Nuclear Information System (INIS)

    van Dijk, J.; Oosterwijk, E.; van Kroonenburgh, M.J.; Jonas, U.; Fleuren, G.J.; Pauwels, E.K.; Warnaar, S.O.

    1988-01-01

    Tumor-bearing human kidneys were used in an ex vivo perfusion model to screen monoclonal antibodies, recognizing renal cell carcinoma-associated antigens for diagnostic potential in vivo. Perfusion of tumor-bearing kidneys with /sup 99m/Tc-labeled G250 and RC38 antibody resulted in visualization of the tumor, whereas perfusion with two other monoclonal antibodies, RC2 and RC4, did not lead to tumor visualization. Uptake of radiolabel in normal kidney tissue was low for G250 and RC38 antibody. Tumor-to-kidney tissue ratios after perfusion with G250 and RC38 antibody were 2.7 and 2.2, respectively. After rinsing for 3 hr with unlabeled perfusion fluid the tumor-to-kidney tissue ratios increased to 8.6 for G250 antibody and to 2.7 for RC38 antibody. We conclude that perfusion of tumor-bearing human kidneys with radiolabeled monoclonal antibodies is a relatively simple way to evaluate renal cell carcinoma associated monoclonal antibodies as diagnostic agents in vivo

  17. Intrahemispheric Perfusion in Chronic Stroke-Induced Aphasia

    Directory of Open Access Journals (Sweden)

    Cynthia K. Thompson

    2017-01-01

    Full Text Available Stroke-induced alterations in cerebral blood flow (perfusion may contribute to functional language impairments and recovery in chronic aphasia. Using MRI, we examined perfusion in the right and left hemispheres of 35 aphasic and 16 healthy control participants. Across 76 regions (38 per hemisphere, no significant between-subjects differences were found in the left, whereas blood flow in the right was increased in the aphasic compared to the control participants. Region-of-interest (ROI analyses showed a varied pattern of hypo- and hyperperfused regions across hemispheres in the aphasic participants; however, there were no significant correlations between perfusion values and language abilities in these regions. These patterns may reflect autoregulatory changes in blood flow following stroke and/or increases in general cognitive effort, rather than maladaptive language processing. We also examined blood flow in perilesional tissue, finding the greatest hypoperfusion close to the lesion (within 0–6 mm, with greater hypoperfusion in this region compared to more distal regions. In addition, hypoperfusion in this region was significantly correlated with language impairment. These findings underscore the need to consider cerebral perfusion as a factor contributing to language deficits in chronic aphasia as well as recovery of language function.

  18. Basal hyperaemia is the primary abnormality of perfusion in Takotsubo cardiomyopathy

    DEFF Research Database (Denmark)

    Christensen, Thomas Emil; Ahtarovski, Kiril Aleksov; Bang, Lia Evi

    2015-01-01

    AIMS: Takotsubo cardiomyopathy (TTC) is characterized by acute completely reversible regional left ventricle (LV) akinesia and decreased tracer uptake in the akinetic region on semi-quantitative perfusion imaging. The latter may be due to normoperfusion of the akinetic mid/apical area and basal...... hyperperfusion. Our aim was to examine abnormalities of perfusion in TTC, and we hypothesized that basal hyperperfusion is the primary perfusion abnormality in the acute state. METHOD AND RESULTS: Twenty-five patients were diagnosed with TTC due to (i) acute onset of symptoms, (ii) typical apical ballooning......-on follow-up. Patients initially had severe heart failure, mid/apical oedema but no infarction, and a rise in cardiac biomarkers. On initial perfusion PET imaging, eight patients appeared to have normal, whereas 17 patients had impaired LV perfusion. In the latter, flow in the basal region was increased...

  19. Histogram based analysis of lung perfusion of children after congenital diaphragmatic hernia repair.

    Science.gov (United States)

    Kassner, Nora; Weis, Meike; Zahn, Katrin; Schaible, Thomas; Schoenberg, Stefan O; Schad, Lothar R; Zöllner, Frank G

    2018-05-01

    To investigate a histogram based approach to characterize the distribution of perfusion in the whole left and right lung by descriptive statistics and to show how histograms could be used to visually explore perfusion defects in two year old children after Congenital Diaphragmatic Hernia (CDH) repair. 28 children (age of 24.2±1.7months; all left sided hernia; 9 after extracorporeal membrane oxygenation therapy) underwent quantitative DCE-MRI of the lung. Segmentations of left and right lung were manually drawn to mask the calculated pulmonary blood flow maps and then to derive histograms for each lung side. Individual and group wise analysis of histograms of left and right lung was performed. Ipsilateral and contralateral lung show significant difference in shape and descriptive statistics derived from the histogram (Wilcoxon signed-rank test, phistogram derived parameters. Histogram analysis can be a valuable tool to characterize and visualize whole lung perfusion of children after CDH repair. It allows for several possibilities to analyze the data, either describing the perfusion differences between the right and left lung but also to explore and visualize localized perfusion patterns in the 3D lung volume. Subgroup analysis will be possible given sufficient sample sizes. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Testicular artery arising from an aberrant right renal artery | Suluba ...

    African Journals Online (AJOL)

    This case report we discovered the rare variation of the origin of the right testicular artery arising from the right aberrant renal artery with double renal artery irrigating both left and right kidneys. These variations in the testicular arteries and renal arteries have implication to surgical procedures such as orchidopexy repair for ...

  1. Whole body perfusion for hybrid aortic arch repair: evolution of selective regional perfusion with a modified extracorporeal circuit.

    Science.gov (United States)

    Fernandes, Philip; Walsh, Graham; Walsh, Stephanie; O'Neil, Michael; Gelinas, Jill; Chu, Michael W A

    2017-04-01

    Patients undergoing hybrid aortic arch reconstruction require careful protection of vital organs. We believe that whole body perfusion with tailored dual circuitry may help to achieve optimal patient outcomes. Our circuit has evolved from a secondary circuit utilizing a cardioplegia delivery device for lower body perfusion to a dual-oxygenator circuit. This allows individually controlled regional perfusion with ease of switching from secondary to primary circuit for total body flow. The re-design allows for separate flow and temperature regulation with two oxygenators in parallel. All patients underwent a single-stage operation for simultaneous treatment of arch and descending aortic pathology via a sternotomy, using a hybrid frozen elephant trunk technique. We report six consecutive patients undergoing hybrid arch and frozen elephant trunk reconstruction using a dual-oxygenator circuit. Five patients underwent elective surgery and one was emergent. One patient had an acute dissection while three underwent concomitant procedures, including a Ross procedure and two valve-sparing root reconstructions. Three cases were redo sternotomies. The mean pump time was 358 ± 131 min, the aortic cross clamp time 243 ± 135 min, the cardioplegia volume of 33,208 ml ± 16,173, cerebral ischemia 0 min, lower body ischemia 76 ± 34 min and the average lower body perfusion time was 142 min. Two patients did not require any donor blood products. The median intensive care unit (ICU) and hospital lengths of stay (LOS) were two days and 10 days, respectively. The average peak serum lactate on CPB was 7.47 mmol/L and, at admission to the ICU, it was 3.37 mmol/L. Renal and respiratory failure developed in the salvage acute type A dissection patient. No other complications occurred in this series. Whole body perfusion as delivered through individually controlled dual-oxygenator circuitry allows maximum flexibility for hybrid aortic arch reconstruction. A modified circuit perfusion

  2. RENAL CRYOABLATION

    Directory of Open Access Journals (Sweden)

    A. V. Govorov

    2012-01-01

    Full Text Available Renal cryoablation is an alternative minimally-invasive method of treatment for localized renal cell carcinoma. The main advantages of this methodology include visualization of the tumor and the forming of "ice ball" in real time, fewer complications compared with other methods of treatment of renal cell carcinoma, as well as the possibility of conducting cryotherapy in patients with concomitant pathology. Compared with other ablative technologies cryoablation has a low rate of repeat sessions and good intermediate oncological results. The studies of long-term oncological and functional results of renal cryoablation are presently under way.

  3. Renal blood flow and metabolism after cold ischaemia: peroperative measurements in patients with calculi

    DEFF Research Database (Denmark)

    Petersen, H K; Henriksen, Jens Henrik Sahl

    1984-01-01

    Peroperative measurements of renal blood flow (RBF), renal O2-uptake, and renal venous lactate/pyruvate (L/P) ratio were performed before and after a period of 30-71 min of hypothermic (10-15 degrees C) renal ischaemia in nine patients, undergoing surgery for renal calculi. Before ischaemia, RBF.......01) immediately after re-established perfusion and 36% (P less than 0.02) 30 min later. In one additional patient, who had a short warm ischaemia (8 min), the flow pattern was the same. As arterial pressure remained constant, the reduced RBF signifies an increased renal vascular resistance. Renal O2-uptake...... and renal venous L/P ratio were almost constant, indicating no significant anaerobic processes being involved in the flow response. None of the patients showed any signs of reactive hyperaemia. It is concluded that hypothermic renal ischaemia may be followed by an increased renal vascular resistance even...

  4. Normal Values of Tissue-Muscle Perfusion Indexes of Lower Limbs Obtained with a Scintigraphic Method.

    Science.gov (United States)

    Manevska, Nevena; Stojanoski, Sinisa; Pop Gjorceva, Daniela; Todorovska, Lidija; Miladinova, Daniela; Zafirova, Beti

    2017-09-01

    Introduction Muscle perfusion is a physiologic process that can undergo quantitative assessment and thus define the range of normal values of perfusion indexes and perfusion reserve. The investigation of the microcirculation has a crucial role in determining the muscle perfusion. Materials and method The study included 30 examinees, 24-74 years of age, without a history of confirmed peripheral artery disease and all had normal findings on Doppler ultrasonography and pedo-brachial index of lower extremity (PBI). 99mTc-MIBI tissue muscle perfusion scintigraphy of lower limbs evaluates tissue perfusion in resting condition "rest study" and after workload "stress study", through quantitative parameters: Inter-extremity index (for both studies), left thigh/right thigh (LT/RT) left calf/right calf (LC/RC) and perfusion reserve (PR) for both thighs and calves. Results In our investigated group we assessed the normal values of quantitative parameters of perfusion indexes. Indexes ranged for LT/RT in rest study 0.91-1.05, in stress study 0.92-1.04. LC/RC in rest 0.93-1.07 and in stress study 0.93-1.09. The examinees older than 50 years had insignificantly lower perfusion reserve of these parameters compared with those younger than 50, LC (p=0.98), and RC (p=0.6). Conclusion This non-invasive scintigraphic method allows in individuals without peripheral artery disease to determine the range of normal values of muscle perfusion at rest and stress condition and to clinically implement them in evaluation of patients with peripheral artery disease for differentiating patients with normal from those with impaired lower limbs circulation.

  5. Evaluation of left ventricular function using digital subtraction angiography

    International Nuclear Information System (INIS)

    Kozuka, Takahiro; Ohta, Mitsushige

    1985-01-01

    To evaluate function of the left ventricle and myocardial perfusion images, digital subtraction angiography (DSA) was performed in 45 patients with ischemic heart disease. Validity of the technique was compared with data obtained from cine left ventriculogram in all patients and 201 T1 myocardial images in 20 patients. End-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) calculated from DSA were correlated closely with those from cine left ventriculogram (r = 0.92, r = 0.94 and r = 0.86, respectively). Regional contractility at the antero-lateral wall of the left ventricle, assessed by DSA, was also correlated well with cine left ventriculogram (r = 0.75). Evaluation of the inferior wall motion showed less correlation in both procedures (r = 0.68). Phase and amplitude analysis with the same technique with radionuclide cardiac angiography was successfully applied in left ventriculogram obtained by DSA. The procedure seems to be helpful for objective evaluation of the left ventricular wall motion. Myocardial perfusion image, obtained with modified Radtke's technique, showed good coincidence with 201 T1 images. Thus, DSA is applicable for evaluation of function of the left ventricle and myocardial perfusion in patients with ischemic heart disease. (author)

  6. Local cortical hypoperfusion imaged with CT perfusion during postictal Todd's paresis

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, Marlon S.; Binder, Devin K. [University of California, Department of Neurological Surgery, Irvine, CA (United States); Smith, Wade S. [University of California, Department of Neurology, San Francisco, CA (United States); Wintermark, Max; Dillon, William P. [University of California, Department of Radiology, San Francisco, CA (United States)

    2008-05-15

    Postictal ('Todd's') paralysis, or 'epileptic hemiplegia,' is a well-known complication of focal or generalized epileptic seizures. However, it is unclear whether the pathophysiology of Todd's paralysis is related to alterations in cerebral perfusion. We report CT perfusion findings in a patient presenting with postictal aphasia and right hemiparesis. A 62-year-old woman with a history of alcohol abuse, closed head injury and posttraumatic epilepsy, presented with acute onset aphasia and right hemiparesis. A non-contrast head CT scan demonstrated no acute hemorrhage. Left hemispheric ischemia was suspected, and the patient was considered for acute thrombolytic therapy. MRI revealed a subtle increase in signal intensity involving the left medial temporal, hippocampal and parahippocampal regions on both T2-weighted FLAIR and diffusion-weighted sequences. CT angiography and CT perfusion study were performed. The CT perfusion study and CT angiography demonstrated a dramatic reduction in cerebral blood flow and blood volume involving the entire left hemisphere, but with relative symmetry of mean transit time, ruling out a large vessel occlusion. Clinical resolution of the aphasia and hemiparesis occurred within a few hours, and correlated with normalization of perfusion to the left hemisphere (detected by MR perfusion). This unique case is the first in which clinical evidence of Todd's paralysis has been correlated with reversible postictal hemispheric changes on CT and MR perfusion studies. This is important because CT perfusion study is being used more and more in the diagnosis of acute stroke, and one needs to be careful to not misinterpret the data. (orig.)

  7. Local cortical hypoperfusion imaged with CT perfusion during postictal Todd's paresis

    International Nuclear Information System (INIS)

    Mathews, Marlon S.; Binder, Devin K.; Smith, Wade S.; Wintermark, Max; Dillon, William P.

    2008-01-01

    Postictal (''Todd's'') paralysis, or ''epileptic hemiplegia,'' is a well-known complication of focal or generalized epileptic seizures. However, it is unclear whether the pathophysiology of Todd's paralysis is related to alterations in cerebral perfusion. We report CT perfusion findings in a patient presenting with postictal aphasia and right hemiparesis. A 62-year-old woman with a history of alcohol abuse, closed head injury and posttraumatic epilepsy, presented with acute onset aphasia and right hemiparesis. A non-contrast head CT scan demonstrated no acute hemorrhage. Left hemispheric ischemia was suspected, and the patient was considered for acute thrombolytic therapy. MRI revealed a subtle increase in signal intensity involving the left medial temporal, hippocampal and parahippocampal regions on both T2-weighted FLAIR and diffusion-weighted sequences. CT angiography and CT perfusion study were performed. The CT perfusion study and CT angiography demonstrated a dramatic reduction in cerebral blood flow and blood volume involving the entire left hemisphere, but with relative symmetry of mean transit time, ruling out a large vessel occlusion. Clinical resolution of the aphasia and hemiparesis occurred within a few hours, and correlated with normalization of perfusion to the left hemisphere (detected by MR perfusion). This unique case is the first in which clinical evidence of Todd's paralysis has been correlated with reversible postictal hemispheric changes on CT and MR perfusion studies. This is important because CT perfusion study is being used more and more in the diagnosis of acute stroke, and one needs to be careful to not misinterpret the data. (orig.)

  8. [Current role of color Doppler ultrasound in acute renal failure].

    Science.gov (United States)

    Bertolotto, M; Quaia, E; Rimondini, A; Lubin, E; Pozzi Mucelli, R

    2001-01-01

    Acute Renal Failure (ARF) is characterized by a rapid decline of the glomerular filtration rate, due to hypotension (prerenal ARF), obstruction of the urinary tract (post-renal ARF) or renal parenchymal disease (renal ARF). The differential diagnosis among different causes of ARF is based on anamnesis, clinical symptoms and laboratory data. Usually ultrasound (US) is the only imaging examination performed in these patients, because it is safe and readily available. In patients with ARF gray scale US is usually performed to rule out obstruction since it is highly sensitive to recognize hydronephrosis. Patients with renal ARF have no specific changes in renal morphology. The size of the kidneys is usually normal or increased, with smooth margins. Detection of small kidneys suggests underlying chronic renal pathology and worse prognosis. Echogenicity and parenchymal thickness are usually normal, but in some cases there are hyperechogenic kidneys, increased parenchymal thickness and increased cortico-medullary differentiation. Evaluation of renal vasculature with pulsed Doppler US is useful in the differential diagnosis between prerenal ARF and acute tubular necrosis (ATN), and in the diagnosis of renal obstruction. Latest generation US apparatus allow color Doppler and power Doppler evaluation of renal vasculature up to the interlobular vessels. A significant, but non specific, reduction in renal perfusion is usually appreciable in the patients with ARF. There are renal pathologic conditions presenting with ARF in which color Doppler US provides more specific morphologic and functional information. In particular, color Doppler US often provides direct or indirect signs which can lead to the right diagnosis in old patients with chronic renal insufficiency complicated with ARF, in patients with acute pyelonephritis, hepatic disease, vasculitis, thrombotic microangiopathies, and in patients with acute thrombosis of the renal artery and vein. Contrast enhanced US is

  9. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  10. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  11. Sonographic determination of spleen to left kidney ratio among Igbo ...

    African Journals Online (AJOL)

    The weight and height of the subjects were obtained with the participants wearing light ... Results: Measurement of spleen and left kidney lengths were reliable within and between .... obtained in the coronal plane passing through the renal.

  12. Placental perfusion - a human alternative

    DEFF Research Database (Denmark)

    Mose, Tina; Knudsen, Lisbeth E

    2006-01-01

    Foetal exposures to environmental and medicinal products have impact on the growth of the foetus (e.g. cigarette smoke) and development of organs (e.g. methylmercury and Thalidomide). Perfusion studies of the human term placenta enable investigation of placental transport of chemical substances...... between the mother and foetus. Dual perfusion of a single cotyledon in the human placenta can contribute to a better understanding of the placental barrier, transport rate and mechanisms of different substances and placental metabolism. The perfusion system has recently been established in Copenhagen...

  13. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning.

    Science.gov (United States)

    Kunst, P W; Vonk Noordegraaf, A; Hoekstra, O S; Postmus, P E; de Vries, P M

    1998-11-01

    Electrical impedance tomography (EIT) is a technique that makes it possible to measure ventilation and pulmonary perfusion in a volume that approximates to a 2D plane. The possibility of using EIT for measuring the left-right division of ventilation and perfusion was compared with that of radionuclide imaging. Following routine ventilation (81mKr) and perfusion scanning (99mTc-MAA), EIT measurements were performed at the third and the sixth intercostal level in 14 patients with lung cancer. A correlation (r = 0.98, p RC) was calculated for estimating the left-right division with EIT. The RC for the ventilation measurements was 94% and 96% for the perfusion measurements. The correlation analysis for reproducibility of the EIT measurements was 0.95 (p < 0.001) for the ventilation and 0.93 (p < 0.001) for the perfusion measurements. In conclusion, EIT can be regarded as a promising technique to estimate the left-right division of pulmonary perfusion and ventilation.

  14. Nuclear magnetic resonance of perfused tissue

    International Nuclear Information System (INIS)

    Harpen, M.D.; Allison, R.C.

    1986-01-01

    The effect of perfusion on the NMR signal observed in NMR imaging is studied in a phantom and in two isolated perfused canine lungs. It is observed that perfusion in tissue has little effect on longitudinal relaxation times. Transverse relaxation rates are observed to correlate linearly with rates of perfusion, in accordance with a model presented. (author)

  15. SPM analysis of brain perfusion SPECT and F-18 FDG PET in the Korean autosomal dominant nocturnal frontal lobe epilepsy family

    International Nuclear Information System (INIS)

    Won, Kyoung Sook; Zeon, Seok Kil

    2004-01-01

    This study attempted to investigate the specific pattern of brain perfusion and glucose metabolism in the Korean autosomal dominant nocturnal frontal lobe epilepsy (ADNFLE) family. Using Tc-99m ECD brain perfusion SPECT. we assessed brain perfusion in 6 patients at interictal period and 5 patients at ictal period. Interictal F-18 FDG PET was performed on 6 affected family members. The scans were statistically analyzed by using statistical parametric mapping (SPM99). The data of the affected family members were compared to those of the control subjects. Interictal F-18 FDG PET SPM group analysis showed decreased glucose metabolism over the left middle and superior frontal gyri and the left central regions including the anterior parietal lobe. There was a less pronounced decrease in glucose uptake in the right anterior superior frontal gyrus. Interictal brain perfusion SPECT SPM group analysis showed similar pattern of decreased perfusion compared to those of interictal F-18 FDG PET. Ictal brain perfusion SPECT SPM group analysis revealed increased perfusion over the left pre-and postcentral gyri and less pronounced increased perfusion in the right postcentral gyrus. lnterictal F -18 PET and brain perfusion SPECT SPM group analysis suggest that major abnormalities of ADNFLE family are in the left frontal lobe. These findings may be helpful to elucidate the pathophysiological mechanism of this rare disease entity

  16. SPM analysis of brain perfusion SPECT and F-18 FDG PET in the Korean autosomal dominant nocturnal frontal lobe epilepsy family

    Energy Technology Data Exchange (ETDEWEB)

    Won, Kyoung Sook; Zeon, Seok Kil [Keimyung University Dongsan Medical Center, Daegu (Korea, Republic of)

    2004-07-01

    This study attempted to investigate the specific pattern of brain perfusion and glucose metabolism in the Korean autosomal dominant nocturnal frontal lobe epilepsy (ADNFLE) family. Using Tc-99m ECD brain perfusion SPECT. we assessed brain perfusion in 6 patients at interictal period and 5 patients at ictal period. Interictal F-18 FDG PET was performed on 6 affected family members. The scans were statistically analyzed by using statistical parametric mapping (SPM99). The data of the affected family members were compared to those of the control subjects. Interictal F-18 FDG PET SPM group analysis showed decreased glucose metabolism over the left middle and superior frontal gyri and the left central regions including the anterior parietal lobe. There was a less pronounced decrease in glucose uptake in the right anterior superior frontal gyrus. Interictal brain perfusion SPECT SPM group analysis showed similar pattern of decreased perfusion compared to those of interictal F-18 FDG PET. Ictal brain perfusion SPECT SPM group analysis revealed increased perfusion over the left pre-and postcentral gyri and less pronounced increased perfusion in the right postcentral gyrus. lnterictal F -18 PET and brain perfusion SPECT SPM group analysis suggest that major abnormalities of ADNFLE family are in the left frontal lobe. These findings may be helpful to elucidate the pathophysiological mechanism of this rare disease entity.

  17. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].

    Science.gov (United States)

    Parra-Bravo, José Rafael; Apolonio-Martínez, Adriana; Estrada-Loza, María de Jesús; Beirana-Palencia, Luisa Gracia; Ramírez-Portillo, César Iván

    2015-01-01

    The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusionductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  18. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  19. Renal cancer.

    NARCIS (Netherlands)

    Corgna, E.; Betti, M.; Gatta, G.; Roila, F.; Mulder, P.H.M. de

    2007-01-01

    In Europe, renal cancer (that is neoplasia of the kidney, renal pelvis or ureter (ICD-9 189 and ICD-10 C64-C66)) ranks as the seventh most common malignancy in men amongst whom there are 29,600 new cases each year (3.5% of all cancers). Tobacco, obesity and a diet poor in vegetables are all

  20. Renal cancer

    NARCIS (Netherlands)

    Corgna, Enrichetta; Betti, Maura; Gatta, Gemma; Roila, Fausto; De Mulder, Pieter H. M.

    2007-01-01

    In Europe, renal cancer (that is neoplasia of the kidney, renal pelvis or ureter (ICD-9 189 and ICD-10 C64-C66)) ranks as the seventh most common malignancy in men amongst whom there are 29,600 new cases each year (3.5% of all cancers). Tobacco, obesity and a diet poor in vegetables are all

  1. Endoluminal isoproterenol reduces renal pelvic pressure during semirigid ureterorenoscopy

    DEFF Research Database (Denmark)

    Jakobsen, Jørn S; Jung, Helene U; Gramsbergen, Jan B

    2009-01-01

    OBJECTIVE To investigate the effects on the pressure-flow relation of renal pelvic pressure during semirigid ureterorenoscopy and endoluminal perfusion of isoproterenol (ISO) 0.1 microg/mL, with emphasis on local effects and cardiovascular side-effects, as topically administered ISO effectively...... and dose-dependently causes relaxation of the upper urinary tract in pigs with no concomitant cardiovascular side-effects. MATERIALS AND METHODS In anaesthetized female pigs (60 kg), 16 macroscopically normal upper urinary tract systems were subjected to ureterorenoscopy. Via a subcostal incision a 6-F...... catheter was placed in the renal pelvis for pressure measurements, and a semirigid ureteroscope (7.8 F) was inserted retrogradely in the renal pelvis, through which the pelvis was perfused. The blood pressure and heart rate were recorded. The increase in renal pelvic pressure was examined with increasing...

  2. MR imaging of renal transplant rejection

    International Nuclear Information System (INIS)

    Hanna, S.; Helenon, O.; Legendre, C.; Chichie, J.F.; Di Stefano, D.; Kreis, H.; Moreau, J.F.; Hopital Necker, 75 - Paris

    1991-01-01

    The results of 62 consecutive MR examinations were correlated with the subsequent clinical course and histologic results. Twenty-six cases of rejection showed a marked diminution of cortico-medullary differentiation (CMD). The renal parenchymal vascular pattern and visibility of renal sinus fat were not markedly altered in rejection and there was no difference between normal and rejected allograft shape. The ability of MR imaging to diagnose renal transplant rejection is only based on CMD, which, however, is non-specific. In 2 cases of severe rejection, T2 weighted images showed an abnormal signal intensity of the cortex due to renal infarction. Our preliminary results in 8 patients with Gd-DOTA injection showed 2 cases with necrosis seen as areas with absent contrast enhancement. This technique seems to be promising in the detection of perfusion defects. (orig.)

  3. Arterial spin labelling MRI for detecting pseudocapsule defects and predicting renal capsule invasion in renal cell carcinoma.

    Science.gov (United States)

    Zhang, H; Wu, Y; Xue, W; Zuo, P; Oesingmann, N; Gan, Q; Huang, Z; Wu, M; Hu, F; Kuang, M; Song, B

    2017-11-01

    To evaluate prospectively the performance of combining morphological and arterial spin labelling (ASL) magnetic resonance imaging (MRI) for detecting pseudocapsule defects in renal cell carcinoma (RCC), and to predict renal capsule invasion confirmed histopathologically. Twenty consecutive patients with suspicious renal tumours underwent MRI. Renal ASL imaging was performed and renal blood flow was measured quantitatively. The diagnostic performance of T2-weighted images alone, and a combination of T2-weighted and ASL images for predicting renal capsule invasion were assessed. Twenty renal lesions were evaluated in 20 patients. All lesions were clear cell RCCs (ccRCCs) confirmed at post-surgical histopathology. Fifteen ccRCCs showed pseudocapsule defects on T2-weighted images, of which 12 cases showed existing blood flow in defect areas on perfusion images. To predict renal capsule invasion, the sensitivity, specificity, positive predictive value, and negative predictive value were 100%, 71.4%, 86.7%, 100%, respectively, for T2-weighted images alone, and 92.3%, 100%, 100%, 87.5%, respectively, for the combination of T2-weighted and ASL images. ASL images can reflect the perfusion of pseudocapsule defects and as such, the combination of T2-weighted and ASL images produces promising diagnostic accuracy for predicting renal capsule invasion. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Decreased Lung Perfusion After Breast/Chest Wall Irradiation: Quantitative Results From a Prospective Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Liss, Adam L., E-mail: adamliss68@gmail.com [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Marsh, Robin B. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Kapadia, Nirav S. [Department of Radiation Oncology, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire (United States); McShan, Daniel L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Rogers, Virginia E. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Moran, Jean M.; Brock, Kristy K.; Schipper, Matt J.; Jagsi, Reshma [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Biostatistics Unit, University of Michigan, Ann Arbor, Michigan (United States); Flaherty, Kevin R. [Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States); Frey, Kirk A. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Pierce, Lori J. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2017-02-01

    Purpose: To quantify lung perfusion changes after breast/chest wall radiation therapy (RT) using pre- and post-RT single photon emission computed tomography/computed tomography (SPECT/CT) attenuation-corrected perfusion scans; and correlate decreased perfusion with adjuvant RT dose for breast cancer in a prospective clinical trial. Methods and Materials: As part of an institutional review board–approved trial studying the impact of RT technique on lung function in node-positive breast cancer, patients received breast/chest wall and regional nodal irradiation including superior internal mammary node RT to 50 to 52.2 Gy with a boost to the tumor bed/mastectomy scar. All patients underwent quantitative SPECT/CT lung perfusion scanning before RT and 1 year after RT. The SPECT/CT scans were co-registered, and the ratio of decreased perfusion after RT relative to the pre-RT perfusion scan was calculated to allow for direct comparison of SPECT/CT perfusion changes with delivered RT dose. The average ratio of decreased perfusion was calculated in 10-Gy dose increments from 0 to 60 Gy. Results: Fifty patients had complete lung SPECT/CT perfusion data available. No patient developed symptoms consistent with pulmonary toxicity. Nearly all patients demonstrated decreased perfusion in the left lung according to voxel-based analyses. The average ratio of lung perfusion deficits increased for each 10-Gy increment in radiation dose to the lung, with the largest changes in regions of lung that received 50 to 60 Gy (ratio 0.72 [95% confidence interval 0.64-0.79], P<.001) compared with the 0- to 10-Gy region. For each increase in 10 Gy to the left lung, the lung perfusion ratio decreased by 0.06 (P<.001). Conclusions: In the assessment of 50 patients with node-positive breast cancer treated with RT in a prospective clinical trial, decreased lung perfusion by SPECT/CT was demonstrated. Our study allowed for quantification of lung perfusion defects in a prospective cohort of

  5. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  6. Exercise thallium-201 myocardial imaging in left main coronary artery disease: sensitive but not specific

    International Nuclear Information System (INIS)

    Rehn, T.; Griffith, L.S.; Achuff, S.C.; Bailey, I.K.; Bulkley, B.H.; Burow, R.; Pitt, B.; Becker, L.C.

    1981-01-01

    To determine the usefulness of thallium-201 scintigraphy for identifying left main coronary artery disease, the results of scintigraphy at rest and during exercise were compared in 24 patients with 50 percent or greater narrowing of the left main coronary artery and 80 patients with 50 percent or greater narrowing of one or more of the major coronary arteries but without left main coronary involvement. By segmental analysis of the scintigrams, perfusion defects were assigned to the left anterior descending, left circumflex or right coronary artery, singly or in combination, and the pattern of simultaneous left anterior descending and circumflex arterial defects was used to identify left main coronary artery disease. Of the 24 patients with left main coronary artery disease, 22 (92 percent) had abnormal exercise scintigrams. Despite this high sensitivity, the pattern of perfusion defects was not specific; the ''left main pattern'' was found in 3 patients (13 percent) with left main coronary artery disease but also in 3 (33 percent) of 9 patients with combined left anterior descending and left circumflex arterial disease, 4 (19 percent) of 21 patients with three vessel disease and 3 (6 percent) of 50 patients with one or two vessel disease but excluding the group with left anterior descending plus left circumflex arterial disease. The pattern of perfusion defects in the patients with left main coronary artery disease was determined by the location and severity of narrowings in the coronary arteries downstream from the left main arterial lesion. Concomitant lesions in other arteries were found in all patients with left main coronary disease (one vessel in 1 patient, two vessels in 7 patients and three vessels in 16). For this reason, it is unlikely that even with improvements in radiopharmaceutical agents and imaging techniques, myocardial perfusion scintigraphy will be sufficiently specific for definitive identification of left main coronary artery disease

  7. Anesthesia for parturient with renal transplantation

    Directory of Open Access Journals (Sweden)

    Beena K Parikh

    2012-01-01

    Full Text Available Management of successful pregnancy after renal transplantation is a unique challenge to nephrologist, obstetrician, and anesthesiologist, as these patients have altered physiology and are immune-compromised. We present the anesthetic management of three postrenal transplant patients scheduled for cesarean section. While conducting such cases, cardiovascular status, hematological status, and function of transplanted kidney should be assessed thoroughly. Side effects of immunosuppressant drugs and their interaction with anesthetic agents should be taken into consideration. Main goal of anesthetic management is to maintain optimum perfusion pressure of renal allograft to preserve its function.

  8. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results; Correlacion de la perfusion miocardica corregida por atenuacion con la coronariografia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia C, S.E.; Garcia O, R. [Servicio de Medicina Nuclear, Centro Medico ABC, Campis Observatorio, IAP (Mexico)

    2005-07-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  9. Renal phlebographic findings in painless macrohematuria

    International Nuclear Information System (INIS)

    Seidel, K.; Federschmidt, K.

    1982-01-01

    After extensive review of literature concerning renal varices including suburothelial phlebectasia three cases of painless macrohematuria are recommended with unusual phlebographic findings: 1. a large renoiliac anastomosis combined with associated varices of the ureter, 2. a wide renohemazygal anastomosis draining nearly totally left renal venous blood into the vena cava superior, simultaneous existing varices of renal pelvis and ureter and 3. a persisting circumaortal ring. It is discussed whether phlebographic revealed renal varicosity is origin of bleeding in any case or bleeding may be caused eventually by associated suburothelial phlebectasia. (orig.) [de

  10. MAG3 in a renal transplant with complications

    International Nuclear Information System (INIS)

    Rynderman, J.

    2002-01-01

    Full text: A 42 year-old female presenting with glomerulonephritis induced end stage renal failure was found suitable for a renal transplant (Tx). A cadaveric renal Tx was performed after a prolonged cold ischaemic time of 12 hours (optimal<4 hours). The surgery was uncomplicated and doppler ultrasound (u/s) post surgery demonstrated good perfusion to the transplant. Sequential MAG3 renal scanning, at days 1, 3 and 5 post transplant demonstrated reduced but clearly identifiable perfusion and an accumulation renogram ('hot kidney') consistent with acute tubular necrosis (ATN). These results lead to a biopsy being performed at day 5. The biopsy demonstrated rejection and tubular dilatation m keeping with ATN Intense anti-rejection therapy commenced. The day 7, MAG3 study demonstrated some improvement in perfusion, uptake, and clearance, however, overall function remained impaired Dialysis was resumed. At day 10, the patient developed pain with a distended, firm, and tender abdomen. An urgent MAG3 study demonstrated acute vascular insult with near complete absence of perfusion or function ('cold kidney') and the decrease on accumulation renogram. Renal u/s demonstrated a peri-nephric haematoma and markedly abnormal intra-renal blood flow in keeping with acute rejection. This lead to an emergency renal Tx nephrectomy Macroscopically, the kidney was swollen with extensive necrosis and surrounded by fresh blood, with microscopy showing extensive rejection and venous thrombosis. Post nephrectomy the patient returned to haemodialysis While limited by ATN in the early post Tx period, MAG3 imaging provided timely, accurate and non invasive diagnostic information as to the viability of the renal Tx and to the ultimate decision to remove the kidney. This case also demonstrates the importance of frequent serial scanning in early post Tx monitoring. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  11. Giant kidney worms in a patient with renal cell carcinoma

    OpenAIRE

    Kuehn, Jemima; Lombardo, Lindsay; Janda, William M; Hollowell, Courtney M P

    2016-01-01

    Dioctophyma renale (D. renale), or giant kidney worms, are the largest nematodes that infect mammals. Approximately 20 cases of human infection have been reported. We present a case of a 71-year-old man with a recent history of unintentional weight loss and painless haematuria, passing elongated erythematous tissue via his urethra. CT revealed a left renal mass with pulmonary nodules and hepatic lesions. On microscopy, the erythematous tissue passed was identified as D. renale. On subsequent ...

  12. Radionuclide determination of individual kidney function in the treatment of chronic renal obstruction

    International Nuclear Information System (INIS)

    Belis, J.A.; Belis, T.E.; Lai, J.C.; Goodwin, C.A.; Gabriele, O.F.

    1982-01-01

    Differential radionuclide renal scans can be useful in the management of patients with chronic partial obstruction of 1 kidney. The /sup 99m/Tc diethylenetriaminepentaacetic acid perfusion scan can be used to assess glomerular blood flow. The 131 I orthoiodohippurate renal scan provides qualitative functional information from scintigrams and quantitative evaluation of effective renal plasma flow to each kidney, as well as a total excretory index. Sequential /sup 99m/Tc diethylenetriaminepentaacetic acid and 131 I orthoiodohippurate renal scans were used to assess individual renal function before and after surgical correction of unilateral chronic renal obstruction in 31 patients. The preservation of cortical perfusion on /supb 99m/Tc diethylenetriaminepentaacetic acid scans indicated that potential existed for partial recovery of renal function. Effective renal plasma flow and excretory index determined in conjunction with the 131 I orthoiodohippurate scans provided a quantitative assessment of preoperative renal function, an evaluation of the effect of surgery and a sensitive method for long-term evaluation of differential renal function. Correction of ureteropelvic junction obstruction usually resulted in improvement in unilateral renal function. Neither nephrolithotomy nor extended pyelolithotomy diminished renal function in the kidney subjected to an operation and often improved it. Patients with long-standing distal ureteral obstruction had the least improvement in renal function postoperatively

  13. Vessel encoded arterial spin labeling with cerebral perfusion: preliminary study

    International Nuclear Information System (INIS)

    Wu Bing; Xiao Jiangxi; Xie Cheng; Wang Xiaoying; Jiang Xuexiang; Wong, E.C.; Wang Jing; Guo Jia; Zhang Beiru; Zhang Jue; Fang Jing

    2008-01-01

    Objective: To evaluate a noninvasive vessel encoded imaging for selective mapping of the flow territories of the left and fight internal carotid arteries and vertebral-basilar arteries. Methods: Seven volunteers [(33.5 ± 4.1) years; 3 men, 4 women] and 6 patients [(55.2 ± 3.2) years; 2 men, 4 women] were given written informed consent approved by the institutional review board before participating in the study. A pseudo-continuous tagging pulse train is modified to encode all vessels of interest. The selectivity of this method was demonstrated. Regional perfusion imaging was developed on the same arterial spin labeling sequence. Perfusion-weighted images of the selectively labeled cerebral arteries were obtained by subtraction of the labeled from control images. The CBF values of hemisphere, white matter, and gray matter of volunteers were calculated. The vessel territories on patients were compared with DSA. The low perfusion areas were compared with high signal areas on T 2 -FLAIR. Results: High SNR maps of left carotid, right carotid, and basilar territories were generated in 8 minutes of scan time. Cerebral blood flow values measured with regional perfusion imaging in the complete hemisphere (32.6 ± 4.3) ml·min -1 · 100 g -1 , white matter (10.8 ± 0.9) ml·min -1 ·100 g -1 , and gray matter (55.6±2.9) ml·min -1 · 100 g -1 were in agreement with data in the literature. Vessel encoded imaging in patients had a good agreement with DSA. The low perfusion areas were larger than high signal areas on T 2 -FLAIR. Conclusion: We present a new method capable of evaluating both quantitatively and qualitatively the individual brain- feeding arteries in vivo. (authors)

  14. Hydrostatic determinants of cerebral perfusion

    International Nuclear Information System (INIS)

    Wagner, E.M.; Traystman, R.J.

    1986-01-01

    We examined the cerebral blood flow response to alterations in perfusion pressure mediated through decreases in mean arterial pressure, increases in cerebrospinal fluid (CSF) pressure, and increases in jugular venous (JV) pressure in 42 pentobarbital anesthetized dogs. Each of these three pressures was independently controlled. Cerebral perfusion pressure was defined as mean arterial pressure minus JV or CSF pressure, depending on which was greater. Mean hemispheric blood flow was measured with the radiolabeled microsphere technique. Despite 30-mm Hg reductions in mean arterial pressure or increases in CSF or JV pressure, CBF did not change as long as the perfusion pressure remained greater than approximately 60 mm Hg. However, whenever perfusion pressure was reduced to an average of 48 mm Hg, cerebral blood flow decreased 27% to 33%. These results demonstrate the capacity of the cerebral vascular bed to respond similarly to changes in the perfusion pressure gradient obtained by decreasing mean arterial pressure, increasing JV pressure or increasing CSF pressure, and thereby support the above definition of cerebral perfusion pressure

  15. Renal denervation in a patient with Alport syndrome and rejected renal allograft

    OpenAIRE

    Raju, Narayana; Lloyd, Vincent; Yalagudri, Sachin; Das, Bharati; Ravikishore, A.G.

    2015-01-01

    Renal denervation is a new intervention to treat resistant hypertension. By applying radiofrequency (RF) to renal arteries, sympathetic nerves in adventitia layer of vascular wall can be denervated. Sympathetic hyperactivity is an important contributory factor in hypertension of hemodialysis patients. Hyperactive sympathetic nervous system aggravates hypertension and it can cause complications like left ventricular hypertrophy, heart failure, arrhythmias and atherogenesis. Our report illustra...

  16. [Surgical angioplasty of the left main coronary artery].

    Science.gov (United States)

    Vranes, Mile; Velinović, Milos; Kocica, Mladen; Mikić, Aleksandar; Velimirović, Dusan; Djukić, Petar

    2010-01-01

    The conventional treatment for isolated stenosis of the left main coronary artery is bypass surgery (myocardial revascularization). However, the process of atherosclerosis is not arrested by myocardial revascularization and it will lead to the occlusion of the left main coronary artery. Revascularization will establish retrograde perfusion for 50-70% of the myocardium of the left ventricle. Direct surgical angioplasty of the left main coronary artery enables normal physiological perfusion of the whole myocardium and better myocardial function. The aim of our study is to point out a new surgical approach of treating left main coronary artery stenosis. Between October 2002 and October 2003, direct surgical angioplasty of the main left coronary artery was performed on three patients with isolated stenosis of the left main coronary artery using the anterior approach and the pericardium as a patch. The procedure was performed under total endotracheal anaesthesia and standard cardiopulmonary circulation, moderate hypothermia, anterograde St. Tomas cardioplegia and local cooling. Patients were followed clinically, echocardiographically and by load-tests. All three patients were without complications. In postoperative follow-up (54-68 months) neither angina pectoris nor electrocardiographically registered ischaemic changes were found. Load-tests performed every six months on all three patients were negative. Surgical angioplasty of isolated stenosis of the left main coronary artery is a preferred method for treating this type of coronary disease. Contraindications for this type of treatment are stenosis of the left main coronary artery with bifurcation and advanced calcification of the left main coronary artery.

  17. Renal microvascular disease in an aging population: a reversible process?

    Science.gov (United States)

    Futrakul, Narisa; Futrakul, Prasit

    2008-01-01

    Renal microvascular disease and tubulointerstitial fibrosis are usually demonstrated in aging in humans and animals. It has recently been proposed that renal microvascular disease is the crucial determinant of tubulointerstitial disease or fibrosis. Enhanced circulating endothelial cell loss is a biomarker that reflects glomerular endothelial injury or renal microvascular disease, and fractional excretion of magnesium (FE Mg) is a sensitive biomarker that reflects an early stage of tubulointerstitial fibrosis. In aging in humans, both of these biomarkers are abnormally elevated. In addition, a glomerular endothelial dysfunction determined by altered hemodynamics associated with peritubular capillary flow reduction is substantiated. A correction of such hemodynamic alteration with vasodilators can effectively improve renal perfusion and restore renal function. Thus, anti-aging therapy can reverse the renal microvascular disease and dysfunction associated with the aging process.

  18. Estimation of pulmonary hypertension of congenital heart diseases in children by lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Zheng Jinghao; Zhang Shantong; Zeng Jiye; Jia Hongli; Ji Zhiying; Chen Siyi

    1993-01-01

    The authors report that changes in the distribution of pulmonary perfusion caused by gravitation effect, namely, changes in the total count ratios of the right against the left lung between right and left lateral decubitus positions (rt/lt) could estimate pulmonary hypertension using lung perfusion scintigraphy with 99m Tc-labelled macroaggregated albumin. The results showed: rt/lt was inversely related to mean pulmonary arterial pressure. It is concluded that the method is simple, safe, reproducible, unaffected by cardiac structural abnormality and valuable as a noninvasive approach for the estimation of pulmonary hypertension

  19. Large cerebral perfusion defects observed in brain perfusion SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients

    International Nuclear Information System (INIS)

    So, Young; Kim, Hahn Young; Roh, Hong Gee; Han, Seol Heui

    2007-01-01

    Transient global amnesia (TGA) is a memory disorder characterized by an episode of antegrade amnesia and bewilderment which persists for several hours. We analyzed brain perfusion SPECT findings and clinical outcome of patients who suffered from TGA. From September 2005 to August 2007, 12 patients underwent Tc-99m ECD brain perfusion SPECT for neuroimaging of TGA. All patients also underwent MRI and MRA including DWI (MRI). Among them, 10 patients who could be chased more than 6 months were included in this study. Their average age was 60.74.0 yrs (M: F = 2: 8) and the average duration of amnesia was 4.42.2 hrs (1 hr ∼ 7 hrs). Duration from episode of amnesia to SPECT was 4.32.4 days (1∼9 days). Precipitating factors could be identified in 6 patients: emotional stress 3, hair dyeing 1, taking a nap 1 and angioplasty 1. SPECT and MRI was visually assessed, No cerebral perfusion defect was observed on SPECT in 3 patients and their clinical outcome was all good. Among 7 patients who had cerebral perfusion defects on SPECT, 3 patients had good clinical outcome, while others did not: one had hypercholesterolemia, another had depression, and 2 patients with cerebral perfusion defects at both temporoparetal cortex was later diagnosed as early Alzheimer's disease (AD) and mild cognitive impairment (MCI). MRI was negative in 6 patients and 3 of them had excellent clinical outcome while other 3 were diagnosed as hypercholesterolemia, early AD and MCI. Among 4 patients with positive MRI, 3 showed good clinical outcome and their MRI showed lesions at medial temporal cortex and/or vertebral artery. One patient with microcalcification at left putamen was diagnosed to have depression. Large cerebral perfusion defects on SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients which usually shows negative MRI

  20. Large cerebral perfusion defects observed in brain perfusion SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients

    Energy Technology Data Exchange (ETDEWEB)

    So, Young; Kim, Hahn Young; Roh, Hong Gee; Han, Seol Heui [Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2007-07-01

    Transient global amnesia (TGA) is a memory disorder characterized by an episode of antegrade amnesia and bewilderment which persists for several hours. We analyzed brain perfusion SPECT findings and clinical outcome of patients who suffered from TGA. From September 2005 to August 2007, 12 patients underwent Tc-99m ECD brain perfusion SPECT for neuroimaging of TGA. All patients also underwent MRI and MRA including DWI (MRI). Among them, 10 patients who could be chased more than 6 months were included in this study. Their average age was 60.74.0 yrs (M: F = 2: 8) and the average duration of amnesia was 4.42.2 hrs (1 hr {approx} 7 hrs). Duration from episode of amnesia to SPECT was 4.32.4 days (1{approx}9 days). Precipitating factors could be identified in 6 patients: emotional stress 3, hair dyeing 1, taking a nap 1 and angioplasty 1. SPECT and MRI was visually assessed, No cerebral perfusion defect was observed on SPECT in 3 patients and their clinical outcome was all good. Among 7 patients who had cerebral perfusion defects on SPECT, 3 patients had good clinical outcome, while others did not: one had hypercholesterolemia, another had depression, and 2 patients with cerebral perfusion defects at both temporoparetal cortex was later diagnosed as early Alzheimer's disease (AD) and mild cognitive impairment (MCI). MRI was negative in 6 patients and 3 of them had excellent clinical outcome while other 3 were diagnosed as hypercholesterolemia, early AD and MCI. Among 4 patients with positive MRI, 3 showed good clinical outcome and their MRI showed lesions at medial temporal cortex and/or vertebral artery. One patient with microcalcification at left putamen was diagnosed to have depression. Large cerebral perfusion defects on SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients which usually shows negative MRI.

  1. Allowable variance set on left ventricular function parameter

    International Nuclear Information System (INIS)

    Zhou Li'na; Qi Zhongzhi; Zeng Yu; Ou Xiaohong; Li Lin

    2010-01-01

    Purpose: To evaluate the influence of allowable Variance settings on left ventricular function parameter of the arrhythmia patients during gated myocardial perfusion imaging. Method: 42 patients with evident arrhythmia underwent myocardial perfusion SPECT, 3 different allowable variance with 20%, 60%, 100% would be set before acquisition for every patients,and they will be acquired simultaneously. After reconstruction by Astonish, end-diastole volume(EDV) and end-systolic volume (ESV) and left ventricular ejection fraction (LVEF) would be computed with Quantitative Gated SPECT(QGS). Using SPSS software EDV, ESV, EF values of analysis of variance. Result: there is no statistical difference between three groups. Conclusion: arrhythmia patients undergo Gated myocardial perfusion imaging, Allowable Variance settings on EDV, ESV, EF value does not have a statistical meaning. (authors)

  2. Clinical evaluation of renal scintigram with 123I-OIH and sup(99m)Tc-DTPA in renal transplantation

    International Nuclear Information System (INIS)

    Ishibashi, Akira; Fujino, Awato; Ikeda, Shigeru; Ishii, Katsumi; Nakazawa, Keiji

    1983-01-01

    We have carried out 85 renal scintigrams on the 29 renal transplants last 6 months. Clinical usefulness of 123 I-IIH (ortho-iodohippurate) specially prepared compared with that of sup(99m)Tc-DTPA. The parameters of the vascular phase, perfusion index (PI) and (mean) transit time (TT), for the 123 I-OIH and sup(99m)Tc-DTPA renal scintigrams, were almost identical. Therefore it might be thought that renal circulation of 123 I-OIH is similar to that of sup(99m)Tc-DTPA. Moreover 123 I-OIH can afford us specific information on the exretory phase. The complicated renal transplants are well differentiated from normal functioning ones by B/K ratio of 123 I-OIH. B/K ratio is one of the parameters for the excretory phase. 123 I-OIH could be a useful agent for the clinical evaluation after renal transplantation. (author)

  3. Renal scan

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003790.htm Renal scan To use the sharing features on this ... anaphylaxis . Alternative Names Renogram; Kidney scan Images Kidney anatomy Kidney - blood and urine flow References Chernecky CC, ...

  4. Renal Artery Stenosis (RAS) Case study

    International Nuclear Information System (INIS)

    Zaater, M.K.

    2012-01-01

    Renal Artery Stenosis (RAS), is one of the causes of secondary hypertension; there are many causes of renal artery stenosis, as atherosclerosis of the renal artery which account for 90% of cases of RAS; fibromuscular dysplasia accounts for 10% of RAS. Various causes of thrombophilia either due congenital causes or acquired causes and can lead to RAS. Our patient was presented by acute attack of epistaxis and hypertension. Angiography of the Renal Arteries,are showed no sign of renal artery stenosis. However, the right kidney showed upper pole infarction, and the left kidney showed evidence of functional lower pole renal artery stenosis, although there is no anatomical stenosis detected in angiography. Work up for the cause of thrombophilia did not help in the diagnosis, which may be due to an undiscovered cause of thrombophilia

  5. Renal Hemangiopericytoma

    Directory of Open Access Journals (Sweden)

    İbrahim Halil Bozkurt

    2015-03-01

    Full Text Available Hemangiopericytoma is an uncommon perivascular tumor originating from pericytes in the pelvis, head and tneck, and the meninges; extremely rarely in the urinary system. We report a case of incidentally detected renal mass in which radiologic evaluation was suggestive of renal cell carcinoma. First, we performed partial nephrectomy, and then, radical nephrectomy because of positive surgical margins and the pathological examination of the surgical specimen that revealed a hemangiopericytoma. No additional treatment was administered.

  6. Simultaneous assessment of myocardial perfusion and function during mental stress in patients with chronic coronary artery disease.

    Science.gov (United States)

    Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert

    2003-01-01

    Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS

  7. Thallium-201 myocardial scintigraphy and left ventricular function at rest in patients with rest angina pectoris

    International Nuclear Information System (INIS)

    Hakki, A.H.; Iskandrian, A.S.; Kane, S.A.; Amenta, A.

    1984-01-01

    The purpose of this study was to examine the rest thallium-201 perfusion pattern during angina-free periods in 40 patients with rest angina pectoris secondary to coronary artery disease (greater than or equal to 70% diameter narrowing). Seventeen patients had previous Q wave myocardial infarction. The perfusion defects were considered fixed or reversible, depending on the absence or presence of redistribution in the 4-hour delayed images. There were 40 perfusion defects (26 fixed and 14 reversible) in 27 patients whereas 13 patients had normal scans. Reversible perfusion defects were present in 10 patients (25%). Of the 26 fixed perfusion defects, 17 did not have corresponding Q waves. Occluded vessels (63%) had more perfusion defects than vessels with subtotal occlusion (30%) (p less than 0.01). The perfusion defect size was larger in patients with lower ejection fraction than in patients with higher ejection fraction. We conclude: (1) perfusion defects are common in patients with rest angina and are reversible in 25% of patients indicating reduced regional coronary blood flow; (2) the degree of stenosis affects the presence of perfusion defect; (3) fixed defects may be present without corresponding Q waves; and (4) global left ventricular function is related to the size of perfusion defects

  8. Rare case of left adrenal cortical carcinoma with level 3 inferior vena ...

    African Journals Online (AJOL)

    Observation: A 21-year-old male, incidentally detected with left supra renal tumor invading the left renal vein and the thrombus extending into the supra diaphragmatic IVC, underwent laparotomy with simultaneous median sternotomy on total cardiac bypass for removal of IVC tumor thrombus and radical excision of the ...

  9. MYOCARDIAL PERFUSION ASSESSMENT IN FORECASTING EFFECT OF CORONARY ANGIOPLASTY IN PATIENTS WITH ISCHEMIC CHRONIC HEART FAILURE

    Directory of Open Access Journals (Sweden)

    A. B. Mironkov

    2015-01-01

    Full Text Available Aim. To define influence of the left ventricle (LV perfusion defects on the clinical status dynamics after coronary angioplasty in patients with the expressed myocardium dysfunction of ischemic etiology. Materials and methods. Examined 86 patients (81 men and 5 women aged from 46 to 73 years before and in 2–3 days after percutaneous coronary intervention with diagnosis: CAD, CHF with NYHA class III–IV, echocardiography parameters of LV: ejection fraction less than 40%, end-diastolic volume is more than 200 ml. Perfusion defects of myocardium estimated with use of ECG-gated single photon emission computed tomography. Predictors were defined: perfusion defects on LV apex (in score, perfusion defects in the area of LAD, LCx and RCA (%, the LV global perfusion defects (in score and %. Results. In 42% of cases 6-minute walk test increased to 3 times; The NYHA class decreased by 2 classes (group 1. In 28 cases 6-minute walk test increased to 2 times and the NYHA class decreased on 1 class. In 22 patients 6-minute walk test increased less than 50% of reference values and there was no dynamics NYHA class (50 patients of the group 2. Initial extent of LV global perfusion defects in group 1 – 41,2 ± 4,0%, in group 2 – 58,3 ± 2,4% (р = 0,0004. Similar values are received for perfusion indicators in the area of LAD and the LV apex. Prevalence of myocardial perfusion defects at rest reflects prevalence of a cardiosclerosis in a cardiac muscle. Conclusion. Degree of LV myocardial perfusion defects in patients with the expressed heart failure of ischemic etiology is the key indicator influencing clinical efficiency of coronary angioplasty. Critical size for definition of the favorable forecast of revascularization are 60% and more perfusion defects testifying that in a cardiac muscle the focal cardiosclerosis prevails over the functioning myocardium. 

  10. Multiple vascular anomalies involving renal, testicular and suprarenal arteries

    Directory of Open Access Journals (Sweden)

    Suresh Rao

    2015-09-01

    Full Text Available Knowledge of variations of blood vessels of the abdomen is important during operative, diagnostic and endovascular pro- cedures. During routine dissection of the abdominal cavity, we came across multiple vascular anomalies involving renal, suprarenal and testicular arteries. The left kidney was supplied by two renal arteries originating together from the abdomi- nal aorta, and the right kidney was supplied by two accessory renal arteries, one of which was arising from the right renal artery and the other one from the aorta (about 2 inches below the origin of the renal artery. Accessory renal veins were present on both sides. The right testicular artery was arising from the lower accessory renal artery. The left testicular artery was looping around the inferior tributary of the left renal vein, whereby forming a sharp kink. The left middle suprarenal artery was diving into three small branches; the upper two branches were supplying the left suprarenal gland, whereas the lower branch was supplying the left kidney. Furthermore, detailed literature and the clinical and surgical importance of the case are discussed. [Arch Clin Exp Surg 2015; 4(3.000: 168-171

  11. 'Motion frozen' quantification and display of myocardial perfusion gated SPECT

    International Nuclear Information System (INIS)

    Slomka, P.J.; Hurwitz, G.A.; Baddredine, M.; Baranowski, J.; Aladl, U.E.

    2002-01-01

    Aim: Gated SPECT imaging incorporates both functional and perfusion information of the left ventricle (LV). However perfusion data is confounded by the effect of ventricular motion. Most existing quantification paradigms simply add all gated frames and then proceed to extract the perfusion information from static images, discarding the effects of cardiac motion. In an attempt to improve the reliability and accuracy of cardiac SPECT quantification we propose to eliminate the LV motion prior to the perfusion quantification via automated image warping algorithm. Methods: A pilot series of 14 male and 11 female gated stress SPECT images acquired with 8 time bins have been co-registered to the coordinates of the 3D normal templates. Subsequently the LV endo and epi-cardial 3D points (300-500) were identified on end-systolic (ES) and end-diastolic (ED) frames, defining the ES-ED motion vectors. The nonlinear image warping algorithm (thin-plate-spline) was then applied to warp end-systolic frame was onto the end-diastolic frames using the corresponding ES-ED motion vectors. The remaining 6 intermediate frames were also transformed to the ED coordinates using fractions of the motion vectors. Such warped images were then summed to provide the LV perfusion image in the ED phase but with counts from the full cycle. Results: The identification of the ED/ES corresponding points was successful in all cases. The corrected displacement between ED and ES images was up to 25 mm. The summed images had the appearance of the ED frames but have been much less noisy since all the counts have been used. The spatial resolution of such images appeared higher than that of summed gated images, especially in the female scans. These 'motion frozen' images could be displayed and quantified as regular non-gated tomograms including polar map paradigm. Conclusions: This image processing technique may improve the effective image resolution of summed gated myocardial perfusion images used for

  12. Idiopathic renal hematuria in a dog; the usefulness of a method of partial occlusion of the renal artery.

    Science.gov (United States)

    Mishina, M; Watanabe, T; Yugeta, N; Maeda, H; Fujii, K; Wakao, Y; Takahashi, M; Yamamura, H

    1997-04-01

    Exploratory laparotomy was performed on a dog suspected of having idiopathic renal hematuria. Two catheters were inserted into the bilateral ureters, and hematuria from the left kidney was confirmed. The blood flow was occluded in the ventral and dorsal rami of the left renal artery in order to localize the site of hemorrhage. As hematuria disappeared when the dorsal ramus was occluded, the site of renal hematuria was localized to the area dominated by the dorsal ramus of the renal artery. As a result of ligating the dorsal ramus of the left renal artery in this dog, renal hematuria subsided, and the dog has shown a favorable course, to date, one year after surgery.

  13. Herpes simplex encephalitis: increased retention of Tc-99m HMPAO on acetazolamide enhanced brain perfusion SPECT

    International Nuclear Information System (INIS)

    Choi, Yun Young; Kim, Kwon Hyung; Kim, Seung Hyun; Cho, Suk Shin

    1998-01-01

    We present an interesting case of herpes simplex encephalitis, which showed increased upta unilateral temporal cortex on brain perfusion SPECT using Tc-99m HMPAO, but in bilateral tem cortex after acetazolamide administration. A 42-year-old man was admitted via emergency room, due to rapidly progressing hea disorientation and mental changes. On neurologic examination, neck stiffness and Kernig sign noted. CSF examination showed pleocytosis with lymphcyte predominance. MRI showed swelling bilateral temporal lobe with left predominance, suggestive of herpes simplex encephalitis. Baseline/ Acetazolamide brain perfusion SPECT were acquired consecutively at the same position IV administration of 740MBq and additional 1480 MBq of Tc-99m HMPAO respectively. The temporal and inferior frontal cortex showed markedly increased perfusion on the baseline acetazolamide-enhanced SPECT images. The right temporal cortex showed normal uptake on the b SPECT images, and markedly increased uptake after acetazolamide administration, which seemed to the abundant vascularity at the acute inflammation site without marked brain damage. The fo brain perfusion SPECT after 6 months showed perfusion defect in left temporal cortex but norm perfusion in right temporal cortex. Therefore, we can conclude that baseline SPECT is helpful for the prediction of the prognosis acetazolamide SPECT for the evaluation of the extent of herpes simples encephalitis

  14. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    International Nuclear Information System (INIS)

    Namasivayam, Saravanan; Kalra, Mannudeep K.; Waldrop, Sandra M.; Mittal, Pardeep K.; Small, William C.

    2006-01-01

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  15. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Namasivayam, Saravanan [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Kalra, Mannudeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Waldrop, Sandra M. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Mittal, Pardeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Small, William C. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States)]. E-mail: wsmall@emory.edu

    2006-09-15

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  16. Prognostic factors in neonatal acute renal failure

    International Nuclear Information System (INIS)

    Chevalier, R.L.; Campbell, F.; Brenbridge, A.N.

    1984-01-01

    Sixteen infants, 2 to 35 days of age, had acute renal failure, a diagnosis based on serum creatinine concentrations greater than 1.5 mg/dL for at least 24 hours. Eight infants were oliguric (urine flow less than 1.0 mL/kg/h) whereas the remainder were nonoliguric. To determine clinical parameters useful in prognosis, urine flow rate, duration of anuria, peak serum creatinine, urea (BUN) concentration, and nuclide uptake by scintigraphy were correlated with recovery. Nine infants had acute renal failure secondary to perinatal asphyxia, three had acute renal failure as a result of congenital cardiovascular disease, and four had major renal anomalies. Four oliguric patients died: three of renal failure and one of heart failure. All nonoliguric infants survived with mean follow-up serum creatinine concentration of 0.8 +/- 0.5 (SD) mg/dL whereas that of oliguric survivors was 0.6 +/- 0.3 mg/dL. Peak serum creatinine concentration did not differ between those patients who were dying and those recovering. All infants who were dying remained anuric at least four days and revealed no renal uptake of nuclide. Eleven survivors were anuric three days or less, and renal perfusion was detectable by scintigraphy in each case. However, the remaining survivor (with bilateral renal vein thrombosis) recovered after 15 days of anuria despite nonvisualization of kidneys by scintigraphy. In neonates with ischemic acute renal failure, lack of oliguria and the presence of identifiable renal uptake of nuclide suggest a favorable prognosis

  17. Prognostic factors in neonatal acute renal failure

    Energy Technology Data Exchange (ETDEWEB)

    Chevalier, R.L.; Campbell, F.; Brenbridge, A.N.

    1984-08-01

    Sixteen infants, 2 to 35 days of age, had acute renal failure, a diagnosis based on serum creatinine concentrations greater than 1.5 mg/dL for at least 24 hours. Eight infants were oliguric (urine flow less than 1.0 mL/kg/h) whereas the remainder were nonoliguric. To determine clinical parameters useful in prognosis, urine flow rate, duration of anuria, peak serum creatinine, urea (BUN) concentration, and nuclide uptake by scintigraphy were correlated with recovery. Nine infants had acute renal failure secondary to perinatal asphyxia, three had acute renal failure as a result of congenital cardiovascular disease, and four had major renal anomalies. Four oliguric patients died: three of renal failure and one of heart failure. All nonoliguric infants survived with mean follow-up serum creatinine concentration of 0.8 +/- 0.5 (SD) mg/dL whereas that of oliguric survivors was 0.6 +/- 0.3 mg/dL. Peak serum creatinine concentration did not differ between those patients who were dying and those recovering. All infants who were dying remained anuric at least four days and revealed no renal uptake of nuclide. Eleven survivors were anuric three days or less, and renal perfusion was detectable by scintigraphy in each case. However, the remaining survivor (with bilateral renal vein thrombosis) recovered after 15 days of anuria despite nonvisualization of kidneys by scintigraphy. In neonates with ischemic acute renal failure, lack of oliguria and the presence of identifiable renal uptake of nuclide suggest a favorable prognosis.

  18. Comparison of two-dimensional MR angiography and microsphere measurement of renal blood flow for detection of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.A.; Lorenz, C.H.; Shetty, A.N.; Holburn, G.E.; Price, R.R.

    1990-01-01

    This paper compares depiction of the renal arteries by MR angiography to renal blood flow as determined with microspheres in a dog model of renal artery stenosis. A left renal artery stenosis was created by placement of a silk ligature. Nb-95-labeled microspheres were injected into the left ventricle and a reference blood sample was drawn. The dog was imaged in the 1.5-T MR imager with two-dimensional MR angiography sequences. The kidneys were excised, weighted, divided into sections, and counted. Two dogs were studied to date. In dog 1, left renal blood flow (RBF) was 42 mL/min/100 g and right RBF was 337 mL/min/100 g. In dog 2 left RBF was 44 mL/min/100 g and right RBF was 608 mL/min/100 g

  19. Renal autotransplantation--a possibility in the treatment of complex renal vascular diseases and ureteric injuries.

    Science.gov (United States)

    Hau, Hans Michael; Bartels, Michael; Tautenhahn, Hans-Michael; Morgul, Mehmet Haluk; Fellmer, Peter; Ho-Thi, Phuc; Benckert, Christoph; Uhlmann, Dirk; Moche, Michael; Thelen, Armin; Schmelzle, Moritz; Jonas, Sven

    2012-12-31

    We report our contemporary experiences with renal autotransplantation in patients with complicated renal vascular diseases and/or complex ureteral injuries. Since its first performance, renal autotransplantation has been steadily improved and become a safe and effective procedure. Between 1998 and 2006, 6 renal autotransplantations in 6 patients were performed at the University Medical Center of Leipzig. After nephrectomy and renal perfusion ex vivo, the kidney was implanted standardized in the fossa iliaca. The vessels were anastomized to the iliac vessels, the ureter was reimplanted in an extravesical tunneled ureteroneocystostomy technique according to Lich-Gregoir. Demographic, clinical, and laboratory data of the patients were collected and analyzed for pre-, intra-, and postoperative period. Indications for renal autotransplantation were complex renovascular diseases in 2 patients (1 with fibromuscular dysplasia and 1 with Takayasu's arteritis) and in 4 patients with complex ureteral injuries. The median duration of follow-up was 9.7 years (range: 5.6-13.3). The laboratory values of our 6 patients showed improvements of creatinine, urea and blood pressure levels in comparison to the preoperative status at the end of follow-up period. The present study reports excellent results of renal autotransplantation in patients with renovascular disease or complex ureteric injuries. After a median follow-up of 9.7 years all 6 patients present with stable renal function as well as normal blood pressure values. Postoperative complications were observed with a rate comparable to other studies.

  20. Ultrasonography assessment of renal size and its correlation with body mass index in adults without known renal disease

    International Nuclear Information System (INIS)

    Raza, M.; Hameed, A.; Khan, M.I.

    2012-01-01

    Many conditions affect renal size. To evaluate abnormalities in renal size, knowledge of standardised values for normal renal dimensions is essential as it shows variability in the values of normal renal size depending on body size, age and ethnicity. Ultrasound, being an easily available, non-invasive, safe and less expensive modality, is widely used for evaluation of renal dimensions and repeated follow-ups. The objectives of this study were to determine renal size by ultrasound in adults without any known renal disease, and to determine the relationship of renal size with body mass index. Methods: Study was conducted in the Department of Diagnostic Radiology, Shifa International Hospital and PIMS Islamabad. Renal size was assessed by ultrasound in 4,035 adult subjects with normal serum creatinine and without any known renal disease, between November 2002 and December 2010. Renal length, width, thickness and volume were obtained and mean renal length and volume were correlated with body mass index and other factors like age, side, gender, weight and height of the subjects. Results: Mean renal length on right side was 101.6+-8.9 mm, renal width 42.7+-7.1 mm, and parenchymal thickness 14.4+-2.9 mm. On left side, mean renal length was 102.7+-9.2 mm, width 47.6+-7.0 mm, and parenchymal thickness 15.1+-3.1 mm. Mean renal volume on right was 99.8+-37.2 cm/sup 3/ and on left was 124.4+-41.3 cm/sup 3/. Left renal size was significantly larger than right in both genders. Relationship of mean renal length was significant when correlated with age, side, gender, height and weight, and body mass index. Renal volumes also showed a similar relationship with side, gender, height and weight, and body mass index; but with age such a relationship was seen only for left kidney. Conclusion: Pakistani population has mean renal size smaller than reference values available in international literature. Renal length and volume have a direct relationship with body mass index. Mean renal

  1. Effects of Constant Flow vs. Constant Pressure Perfusion on Fluid Filtration in Severe Hypothermic Isolated Blood-Perfused Rat Lungs.

    Science.gov (United States)

    Halsøy, Kathrine; Kondratiev, Timofey; Tveita, Torkjel; Bjertnaes, Lars J

    2016-01-01

    Victims of severe accidental hypothermia are prone to fluid extravasation but rarely develop lung edema. We hypothesize that combined hypothermia-induced increase in pulmonary vascular resistance (PVR) and a concomitant fall in cardiac output protect the lungs against edema development. Our aim was to explore in hypothermic-isolated blood-perfused rat lungs whether perfusion at constant pressure influences fluid filtration differently from perfusion at constant flow. Isolated blood-perfused rat lungs were hanging freely in a weight transducer for measuring weight changes (ΔW). Fluid filtration coefficient (Kfc), was determined by transiently elevating left atrial pressure (Pla) by 5.8 mmHg two times each during normothermia (37°C) and during hypothermia (15°C). The lung preparations were randomized to two groups. One group was perfused with constant flow (Constant flow group) and the other group with constant pulmonary artery pressure (Constant PPA group). Microvascular pressure (Pmv) was determined before and during elevation of Pla (ΔPmv) by means of the double occlusion technique. Kfc was calculated with the formula Kfc = ΔW/ΔPmv/min. All Kfc values were normalized to predicted lung weight (P LW ), which was based on body weight (BW) according to the formula: P LW  = 0.0053 BW - 0.48 and presented as Kfc PLW in mg/min/mmHg/g. At cessation, bronchoalveolar lavage (BAL) fluid/perfusate protein concentration (B/P) ratio was determined photometrically. Data were analyzed with parametric or non-parametric tests as appropriate. p  Kfc PLW and B/P ratio increased significantly by more than 10-fold during hypothermia concerted by visible signs of edema in the trachea. Hemoglobin and hematocrit increased within the Constant flow group and between the groups at cessation of the experiments. In hypothermic rat lungs perfused at constant flow, fluid filtration coefficient per gram P LW and B/P ratio increased more than 10-fold concerted by increased

  2. A new clinical tool for the quantification of myocardial CT perfusion imaging in patients with suspected Ischemic Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Muñoz, A.; Dux-Santoy Hurtado, L.; Rodriguez Palomares, J.L.; Piella Fenoy, G.

    2016-07-01

    In the clinical practice, the evaluation of myocardial perfusion by using Computed Tomography (CT) Imaging is usually performed visually or semi-quantitatively. The scarcity of quantitative perfusion data not always allows a proper diagnose of patients which are suspected of suffering from some diseases, such as Ischemic Heart Disease (IHD). In this work, a clinical tool for the automatic quantification of myocardial perfusion in patients with suspected IHD is proposed. Myocardial perfusion is assessed based on a combined diagnosis protocol (CT/CTP protocol) which involves the acquisition of two contrastenhanced CT images, one obtained at rest and another acquired under pharmacological stress. The clinical tool allows the automatic quantification of perfusion in different myocardial segments defined according to the 16-AHA-segmentation model of the left ventricle, by providing the mean of Hounsfield Units in those regions. Based on this analysis, the clinicians can compare the values at baseline and at hyperemia, and they can better determine hypoperfusion defects in patients with IHD. The validation of the clinical tool was performed by comparing automatic and manual perfusion measurements of 10 patients with suspected IHD who were previously assessed with Single Photon Emission Computed Tomography (SPECT) for perfusion analysis. A strong linear correlation was found between the automatic and manual results. Afterwards, perfusion defects obtained from CT/CTP protocol were compared to perfusion defects from SPECT, to assess the applicability of this clinical tool for the diagnosis of IHD. (Author)

  3. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  4. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  5. Lung perfusion scintigraphy by SPECT

    International Nuclear Information System (INIS)

    Hirayama, Takanobu

    1990-01-01

    The initial study reports the characteristic performance using lung segmental phantom filled in Tc-99m pertechnetate. To evaluate the segmental defect in lung perfusion scintigraphy, we applied Bull's-eye analysis in addition to planar image set. Bull's-eye analysis especially facilitated the interpretation in both middle and lower lobes. Subsequently, to evolute the clinical application of Bull's-eye analysis, pulmonary scintigraphy was performed on 10 normal subjects and 60 patients with several pulmonary diseases. Of interest, Bull's-eye analysis, however, encouraged the interpretation in both lower lobes. To calculate the extention and severity of perfusion defect, the present study describes Bull's-eye analysis. Quantitative scoring showed higher in patients with lung cancer than those with pulmonary tuberculosis. The present study focus that Bull's-eye analysis can be useful for evaluating perfusion in patients with a couple of pulmonary diseases. (author)

  6. Metanephric Adenofibroma associated with Papillary Renal CeU Carcinoma

    International Nuclear Information System (INIS)

    Roa, Carmen Lucia B; Navarrete, Maria Constanza

    2008-01-01

    Metanephric adenofibroma is an infrequent biphasic epithelial-stromal renal tumor, occasionally associated with papillary renal cell carcinoma. We describe a case of a girl with a four year clinical history of intermittent hematuria; she was diagnosed, using a left-side tru-cut renal biopsy, with a Wilms' tumor with stromal and epithelial component, with no sign of anaplasia. Later, through the product of the left-side nephrectomy that was performed at the National Cancer institute of Colombia, she was diagnosed with metanephric adenofibroma associated with papillary renal cell carcinoma

  7. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    %, respectively, for SPECT. CONCLUSION: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.......PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography....... MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise...

  8. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results

    International Nuclear Information System (INIS)

    Garcia C, S.E.; Garcia O, R.

    2005-01-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  9. Reversible cold-induced abnormalities in myocardial perfusion and function in systemic sclerosis

    International Nuclear Information System (INIS)

    Alexander, E.L.; Firestein, G.S.; Weiss, J.L.; Heuser, R.R.; Leitl, G.; Wagner, H.N. Jr.; Brinker, J.A.; Ciuffo, A.A.; Becker, L.C.

    1986-01-01

    The effects of peripheral cold exposure on myocardial perfusion and function were studied in 13 patients with scleroderma without clinically evident myocardial disease. Ten patients had at least one transient, cold-induced, myocardial perfusion defect visualized by thallium-201 scintigraphy, and 12 had reversible, cold-induced, segmental left ventricular hypokinesis by two-dimensional echocardiography. The 10 patients with transient perfusion defects all had anatomically corresponding ventricular wall motion abnormalities. No one in either of two control groups (9 normal volunteers and 7 patients with chest pain and normal coronary arteriograms) had cold-induced abnormalities. This study is the first to show the simultaneous occurrence of cold-induced abnormalities in myocardial perfusion and function in patients with scleroderma. The results suggest that cold exposure in such patients may elicit transient reflex coronary vasoconstriction resulting in reversible myocardial ischemia and dysfunction. Chronic recurrent episodes of coronary spasm may lead to focal myocardial fibrosis

  10. Use of gated N-13-NH3 micro-PET to examine left ventricular function in rats

    NARCIS (Netherlands)

    Szymanski, Mariusz K.; Kruizinga, Silvana; Tio, Rene A.; Willemsen, Antoon T. M.; Schaefers, Michael A.; Stegger, Lars; Dierckx, Rudi A.; Hillege, Hans L.; Slart, Riemer H. J. A.

    Introduction: Myocardial perfusion gating techniques offer the possibility of measurement of left ventricular end-systolic (ESV) and end-diastolic volume (EDV) and left ventricular ejection fraction (LVEF) in clinical and preclinical trials. The aim of this study was to evaluate left ventricular

  11. The effect of the use of a TNF-alpha inhibitor in hypothermic machine perfusion on kidney function after transplantation.

    Science.gov (United States)

    Diuwe, Piotr; Domagala, Piotr; Durlik, Magdalena; Trzebicki, Janusz; Chmura, Andrzej; Kwiatkowski, Artur

    2017-08-01

    One of the most important problems in transplantation medicine is the ischemia/reperfusion injury of the organs to be transplanted. The aim of the present study was to assess the effect of tumor necrosis factor-alpha (TNF-alpha) inhibitor etanercept on the machine perfusion hypothermia of renal allograft kidney function and organ perfusion. No statistically significant differences were found in the impact of the applied intervention on kidney machine perfusion during which the average flow and vascular resistance were evaluated. There were no statistically significant differences in the occurrence of delayed graft function (DGF). Fewer events in patients who received a kidney from the etanercept treated Group A compared to the patients who received a kidney from the control Group B were observed when comparing the functional DGF and occurrence of acute rejection episodes, however, there was no statistically significant difference. In summary, no effect of treatment with etanercept an inhibitor of TNF-alpha in a hypothermic machine perfusion on renal allograft renal survival and its perfusion were detected in this study. However, treatment of the isolated organ may be important for the future of transplantation medicine. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. The intrinsic renal compartment syndrome: new perspectives in kidney transplantation.

    Science.gov (United States)

    Herrler, Tanja; Tischer, Anne; Meyer, Andreas; Feiler, Sergej; Guba, Markus; Nowak, Sebastian; Rentsch, Markus; Bartenstein, Peter; Hacker, Marcus; Jauch, Karl-Walter

    2010-01-15

    Inflammatory edema after ischemia-reperfusion may impair renal allograft function after kidney transplantation. This study examines the effect of edema-related pressure elevation on renal function and describes a simple method to relieve pressure within the renal compartment. Subcapsular pressure at 6, 12, 24, 48 hr, and 18 days after a 45 min warm ischemia was determined in a murine model of renal ischemia-reperfusion injury. Renal function was measured by Tc-MAG3 scintigraphy and laser Doppler perfusion. Structural damage was assessed by histologic analysis. As a therapeutic approach, parenchymal pressure was relieved by a standardized circular 0.3 mm incision at the lower pole of the kidney capsule. Compared with baseline (0.9+/-0.3 mm Hg), prolonged ischemia was associated with a sevenfold increase in subcapsular pressure 6 hr after ischemia (7.0+/-1.0 mm Hg; P<0.001). Pressure levels remained significantly elevated for 24 hr. Without therapy, a significant decrease in functional parameters was found with considerably reduced tubular excretion rate (33+/-3.5%, P<0.001) and renal perfusion (64.5+/-6.8%, P<0.005). Histologically, severe tissue damage was found. Surgical pressure relief was able to significantly prevent loss of tubular excretion rate (62.5+/-6.8%, P<0.05) and renal blood flow (96.2+/-4.8%; P<0.05) and preserved the integrity of renal structures. Our data support the hypothesis of the existence of a renal compartment syndrome as a consequence of ischemia-reperfusion injury. Surgical pressure relief effectively prevented functional and structural renal impairment, and we speculate that this approach might be of value for improving graft function after renal transplantation.

  13. Dynamic CT myocardial perfusion imaging identifies early perfusion abnormalities in diabetes and hypertension : Insights from a multicenter registry

    NARCIS (Netherlands)

    Vliegenthart, Rozemarijn; De Cecco, Carlo N.; Wichmann, Julian L.; Meinel, Felix G.; Pelgrim, Gert Jan; Tesche, Christian; Ebersberger, Ullrich; Pugliese, Francesca; Bamberg, Fabian; Choe, Yeon Hyeon; Wang, Yining; Schoepf, U. Joseph

    2016-01-01

    Background: To identify patients with early signs of myocardial perfusion reduction, a reference base for perfusion measures is needed. Objective: To analyze perfusion parameters derived from dynamic computed tomography perfusion imaging (CTPI) in patients with suspected coronary artery disease

  14. The significance of renoscintigraphy for renal transplantation

    International Nuclear Information System (INIS)

    Oei Hong Yoe.

    1981-01-01

    The aim of the study reported here was to evaluate the contribution of renoscintigraphy performed frequently and systematically, for differentiation between the various complications occurring after renal transplantation. Relevant complications of renal transplantation are described, with special attention to the diagnostic methods available at present, and the methods used for radionuclide investigations in renal transplantation are reviewed. The abnormalities seen on the sequential images in ten cases complicated by urine leakage or urinary tract obstruction are described. These are illustrated by the scintigrams and the corresponding radiograms. The results in eight patients whose transplant did not show Hippuran uptake are also described. Transplant failure in five of these eight patients was clearly demonstrated by perfusion scintigraphy. (Auth.)

  15. Automatic assessment of cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur; Stegmann, Mikkel Bille; Larsson, Henrik B.W.

    2004-01-01

    In this paper, a method based on Active Appearance Models (AAM) is applied for automatic registration of myocardial perfusion MRI. A semi-quantitative perfusion assessment of the registered image sequences is presented. This includes the formation of perfusion maps for three parameters; maximum up...

  16. Pulmonary ventilation/perfusion scan

    Science.gov (United States)

    ... to stop eating (fast), be on a special diet, or take any medicines before the test. A chest x-ray is usually done before or after a ventilation and perfusion scan. You wear a hospital gown or comfortable clothing that does not have ...

  17. Value of dynamic susceptibility contrast perfusion MRI in the acute phase of transient global amnesia.

    Directory of Open Access Journals (Sweden)

    Alex Förster

    Full Text Available Transient global amnesia (TGA is a transitory, short-lasting neurological disorder characterized by a sudden onset of antero- and retrograde amnesia. Perfusion abnormalities in TGA have been evaluated mainly by use of positron emission tomography (PET or single-photon emission computed tomography (SPECT. In the present study we explore the value of dynamic susceptibility contrast perfusion-weighted MRI (PWI in TGA in the acute phase.From a MRI report database we identified TGA patients who underwent MRI including PWI in the acute phase and compared these to control subjects. Quantitative perfusion maps (cerebral blood flow (CBF and volume (CBV were generated and analyzed by use of Signal Processing In NMR-Software (SPIN. CBF and CBV values in subcortical brain regions were assessed by use of VOI created in FIRST, a model-based segmentation tool in the Oxford Centre for Functional Magnetic Resonance Imaging of the Brain (FMRIB Software Library (FSL.Five TGA patients were included (2 men, 3 women. On PWI, no relevant perfusion alterations were found by visual inspection in TGA patients. Group comparisons for possible differences between TGA patients and control subjects showed significant lower rCBF values bilaterally in the hippocampus, in the left thalamus and globus pallidus as well as bilaterally in the putamen and the left caudate nucleus. Correspondingly, significant lower rCBV values were observed bilaterally in the hippocampus and the putamen as well as in the left caudate nucleus. Group comparisons for possible side differences in rCBF and rCBV values in TGA patients revealed a significant lower rCBV value in the left caudate nucleus.Mere visual inspection of PWI is not sufficient for the assessment of perfusion changes in TGA in the acute phase. Group comparisons with healthy control subjects might be useful to detect subtle perfusion changes on PWI in TGA patients. However, this should be confirmed in larger data sets and serial PWI

  18. The role of limb perfusion studies in the paediatric ischaemic limb

    African Journals Online (AJOL)

    Immediately after the perfusion study, blood pool images of the areas of interest were ... The hot spot above the left shoulder (white arrow) is the injection site. ... coincided with the clinical presence of dry gangrene of toes and the digits were ...

  19. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  20. Measurement of single-kidney glomerular filtration function from magnetic resonance perfusion renography

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Meiying; Cheng, Yingsheng [Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Shanghai 200233 (China); Zhao, Binghui, E-mail: binghuizhao@163.com [Department of Radiology, Shanghai Tenth People' s Hospital, Tongji University, Shanghai 200072 (China)

    2015-08-15

    Highlights: • MRPR monitors the transit of contrast material through nephron. • MRPR could reveal renal physiological characteristics in quality and quantity. • This review outlines the basics and future challenges of DCE MRPR. - Abstract: Glomerular filtration rate (GFR) describes the flow rate of filtered fluid through the kidney, and is considered to be the reference standard in the evaluation of renal function. There are many ways to test the GFR clinically, such as serum creatinine concentration, blood urea nitrogen and SPECT renography, however, they’re all not a good standard to evaluate the early damage of renal function. In recent years, the improvement of MRI hardware and software makes it possible to reveal physiological characteristics such as renal blood flow or GFR by dynamic contrast enhancement magnetic resonance perfusion renography (DEC MRPR). MRPR is a method used to monitor the transit of contrast material, typically a gadolinium chelate, through the renal cortex, the medulla, and the collecting system. This review outlines the basics of DCE MRPR included acquisition of dynamic MR perfusion imaging, calculation of the contrast concentration from signal intensity and compartment models, and some challenges of MRPR method faced in prospective clinical application.

  1. Renal posttransplant's vascular complications

    Directory of Open Access Journals (Sweden)

    Bašić Dragoslav

    2003-01-01

    present study demonstrate that the rate of this complication in LD group was low, only 0.3%, but significantly higher in CD group - 11.8%. Many factors should be considered in order to understand for such significant difference among these groups. First of all, cadaveric transplant activity in our country is very low. In our series, median waiting period for renal transplantation was 2.8 years in LD group vs. 4.8 years in CD group (p<0.01. Also, vascular damages because of long term hemodialysis are contributing factors. Mean age of CD recipients was 7.4 years bigger vs. LD recipients. Primary cadaveric graft damage by accident and further manipulations during cadaveric donor nephrectomy, preservation and per-fusion are additional factors compromising the quality of cadaveric renal transplant outcome. Also, preoperative evaluation of cadaveric grafts is not as exact as in cases of LD grafts (excretory urography arteriography, etc. In the available transplant literature it is almost impossible to find data about vascular complications by different donor types. Mostly, authors offer experiences related to all transplants and most of them agree that in the present time better results are obtained using living donors [17].

  2. Visual Enhancement of Laparoscopic Partial Nephrectomy With 3-Charge Coupled Device Camera: Assessing Intraoperative Tissue Perfusion and Vascular Anatomy by Visible Hemoglobin Spectral Response

    Science.gov (United States)

    2010-10-01

    reliably distinguish vascular structures during hilar dissection, and detect and monitor changes in renal tissue perfus:ion dw·ing and after warm...and in 25 patients with hilar tu- mors 16 in whom perioperative outcomes were com- parable to those of peripheral tumors. In a retro- spective study...Richstone et al also reported the safe performance of LPN for hilar tumors in 17 patients.17 Repeat partial nephrectomy for ipsilat- eral tumor has

  3. Differences in 99mTc-HMPAO brain SPET perfusion imaging between Tourette's syndrome and chronic tic disorder in children

    International Nuclear Information System (INIS)

    Chiu, N.-T.; Lee, B.-F.; Chang, Y.-C.; Huang, C.-C.; Wang, S.-T.

    2001-01-01

    Early differential diagnosis between Tourette's syndrome and chronic tic disorder is difficult but important because both the outcome and the treatment of these two childhood-onset diseases are distinct. We assessed the sensitivity and specificity of brain single-photon emission tomography (SPET) perfusion imaging in distinguishing the two diseases, and characterized their different cerebral perfusion patterns. Twenty-seven children with Tourette's syndrome and 11 with chronic tic disorder (mean age 9.5 and 8.6 years, respectively) underwent brain SPET with technetium-99m hexamethylpropylene amine oxime (HMPAO). Visual interpretation and semi-quantitative analysis of SPET images were performed. On visual interpretation, 22 of 27 (82%) of the Tourette's syndrome group had lesions characterized by decreased perfusion. The left hemisphere was more frequently involved. None of the children with chronic tic disorder had a visible abnormality. Semi-quantitative analysis showed that, compared with children with chronic tic disorder, children with Tourette's syndrome had significantly lower perfusion in the left lateral temporal area and asymmetric perfusion in the dorsolateral frontal, lateral and medial temporal areas. In conclusion, using the visual approach, brain SPET perfusion imaging is sensitive and specific in differentiating Tourette's syndrome and chronic tic disorder. The perfusion difference between the two groups, demonstrated by semi-quantitative analysis, may be related more to the co-morbidity in Tourette's syndrome than to tics per se. (orig.)

  4. Quantification of myocardial perfusion using cardiac magnetic resonance imaging correlates significantly to rubidium-82 positron emission tomography in patients with severe coronary artery disease

    DEFF Research Database (Denmark)

    Qayyum, Abbas A; Hasbak, Philip; Larsson, Henrik B W

    2014-01-01

    data was compared with Spearman's rho and Bland-Altman analysis. RESULTS: CMRI results were strongly and significantly correlated with PET results for the absolute global myocardial perfusion differences (r=0.805, p=0.001) and for global myocardial perfusion reserve (MPR) (r=0.886, p... territorial level, CMRI results were also significantly correlated with absolute PET myocardial perfusion differences (r=0.737, pr=0.818, pr=0.787, p=0.......001; left anterior descending artery (LAD): r=0.796, p=0.001; left circumflex artery (LCX): r=0.880, pr=0.895, pr=0.886, pr=0.886, p

  5. Magnetic resonance perfusion imaging without contrast media

    International Nuclear Information System (INIS)

    Martirosian, Petros; Graf, Hansjoerg; Schick, Fritz; Boss, Andreas; Schraml, Christina; Schwenzer, Nina F.; Claussen, Claus D.

    2010-01-01

    Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue. After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue. ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time. Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs. (orig.)

  6. Impact of patient motion on myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Huang Kemin; Feng Yanlin; He Xiaohong; Wen Guanghua; Yu Fengwen; Liu Shusheng; Liu Dejun; Yuan Jianwei; Yang Ming

    2008-01-01

    Objective: It is well known that patient motion may cause artifacts in myocardial SPECT images and affect clinical diagnosis. The aim of the study was to evaluate the effects of motion on quality and semi-quantitative results of myocardial perfusion images. Methods: Six healthy volunteers un- derwent myocardial perfusion SPECT. The raw data in each case was manually shifted 1-6 frames and 1 4 pixels, respectively by using the motion correction software. The shifted raw data were then reconstructed. A semi-quantitative software was used to assess the myocardial perfusion of left ventricle. The quality and semi-quantitative results of the tomographic images reconstructed from the raw data with and without motion were compared and analyzed. SPSS 12.0 was used for data analysis. Results: There was no visible artifact and semi-quantitative difference on the data with 1 frame and (or) 1 pixel shift when compared with the original data without shift. The image artifacts became significantly deteriorated when the number of flame and (or) pixel shift was increased. In general, the image artifact of inferior and posterior wall was related to the upward shift, and that of anterior and infero-posterior wall was related to the downward shift, that of septal, anterior, infero-postefior wall and apex was related to right-ward shift, and the septal and infero-posterior wall was related to the left-ward shift. The differences along the x-axis shift were more prominent than that of the y-axis (t=2.848, P<0.01), and the differences in the downward and rightward shift were more severe than the upward and leftward shift (t=2.941, 6.598; all P<0.01), respectively. Conclusions: Image artifacts became significant when there was motion induced by manual shift of more than one flame and (or) one pixel. Different motion directions were closely related to different segments of left ventricle. (authors)

  7. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction

    Directory of Open Access Journals (Sweden)

    Tae Hoon Kim

    2015-12-01

    Full Text Available A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  8. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction.

    Science.gov (United States)

    Kim, Tae Hoon; Shin, Yu Rim; Kim, Young Sam; Kim, Do Jung; Kim, Hyohyun; Shin, Hong Ju; Htut, Aung Thein; Park, Han Ki

    2015-12-01

    A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  9. False iliac artery aneurysm following renal transplantation

    DEFF Research Database (Denmark)

    Levi, N; Sønksen, Jens Otto Reimers; Schroeder, T V

    1999-01-01

    We report a very rare case of a false iliac artery aneurysm following renal transplantation. The patient was a 51-year-old women who presented with a painful 10 x 10 cm pulsating mass in her left iliac fossa. The patient had received a second cadaveric renal transplantation 5 years previously....... The graft never functioned and transplant nephrectomy was performed 2 weeks later. A CT-scanning showed a 10 x 10 cm large aneurysm arising from the left external iliac artery. At operation a large false aneurysm was identified arising from the original transplant anastomotic site. Due to the extent...

  10. Renal artery origins: best angiographic projection angles.

    Science.gov (United States)

    Verschuyl, E J; Kaatee, R; Beek, F J; Patel, N H; Fontaine, A B; Daly, C P; Coldwell, D M; Bush, W H; Mali, W P

    1997-10-01

    To determine the best projection angles for imaging the renal artery origins in profile. A mathematical model of the anatomy at the renal artery origins in the transverse plane was used to analyze the amount of aortic lumen that projects over the renal artery origins at various projection angles. Computed tomographic (CT) angiographic data about the location of 400 renal artery origins in 200 patients were statistically analyzed. In patients with an abdominal aortic diameter no larger than 3.0 cm, approximately 0.5 mm of the proximal part of the renal artery and origin may be hidden from view if there is a projection error of +/-10 degrees from the ideal image. A combination of anteroposterior and 20 degrees and 40 degrees left anterior oblique projections resulted in a 92% yield of images that adequately profiled the renal artery origins. Right anterior oblique projections resulted in the least useful images. An error in projection angle of +/-10 degrees is acceptable for angiographic imaging of the renal artery origins. Patients sex, site of interest (left or right artery), and local diameter of the abdominal aorta are important factors to consider.

  11. A clinical study of thallium-201 scintigraphy in hypertensive patients with and without left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua; Huang Yuying; Qian Xuexian

    2001-01-01

    Objective: Based on coronary angiography, thallium-201 myocardial scintigraphy was evaluated in hypertensive patients with and without left ventricular hypertrophy, and the causes of its perfusion abnormalities were discussed. Methods: Thallium-201 myocardial scintigraphy was performed on 85 patients with clinically suspected coronary artery disease. Coronary angiography was performed on patients with perfusion abnormalities in one month after scintigraphy. Results: The rate of 201 Tl perfusion abnormalities in hypertensive patients with hypertrophy (85.7%) was higher than normal blood pressure (39.3%, P 201 Tl perfusion abnormalities occur in hypertensive patients with hypertrophy. The perfusion abnormalities may be caused not only by coronary large vessel disease, but also by coronary microvascular disease

  12. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Kyung Il; Lee, Young Ju [Ajou Univ. College of Medicine, Seoul (Korea, Republic of); Lim, Tae Hwan [Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of)] [and others

    1997-11-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and {sup 99m}Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4{+-}5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42{+-}0.52 and 2.16{+-}0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia.

  13. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Lee, Young Ju; Lim, Tae Hwan

    1997-01-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and 99m Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4±5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42±0.52 and 2.16±0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia

  14. CT perfusion technique for assessment of early kidney allograft dysfunction: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Helck, A.; Notohamiprodjo, M.; Schoen, F.; Nikolaou, K.; Clevert, D.A.; Reiser, M.; Becker, C. [Ludwig-Maximilians-University of Munich, Department of Clinical Radiology, University Hospitals Grosshadern, Munich (Germany); Wessely, M.; Schoenermarck, U.; Fischereder, M. [Ludwig-Maximilians-University of Munich, Department of Internal Medicine IV, Nephrology, University Hospitals Grosshadern, Munich (Germany); Klotz, E. [Siemens Healthcare, Computed Tomography, Forchheim (Germany)

    2013-09-15

    To assess the benefit of quantitative computed tomography (CT) perfusion for differentiating acute tubular necrosis (ATN) and acute rejection (AR) in kidney allografts. Twenty-two patients with acute kidney allograft dysfunction caused by either AR (n = 6) or ATN (n = 16) were retrospectively included in the study. All patients initially underwent a multiphase CT angiography (CTA) protocol (12 phases, one phase every 3.5 s) covering the whole graft to exclude acute postoperative complications. Multiphase CT dataset and dedicated software were used to calculate renal blood flow. Renal biopsy or clinical course of disease served as the standard of reference. Mean effective radiation dose and mean amount of contrast media were calculated. Renal blood flow values were significantly lower (P = 0.001) in allografts undergoing AR (48.3 {+-} 21 ml/100 ml/min) compared with those with ATN (77.5 {+-} 21 ml/100 ml/min). No significant difference (P = 0.71) was observed regarding creatinine level with 5.65 {+-} 3.1 mg/dl in AR and 5.3 {+-} 1.9 mg/dl in ATN. The mean effective radiation dose of the CT perfusion protocol was 13.6 {+-} 5.2 mSv; the mean amount of contrast media applied was 34.5 {+-} 5.1 ml. All examinations were performed without complications. CT perfusion of kidney allografts may help to differentiate between ATN and rejection. (orig.)

  15. A case of renal cell carcinoma and angiomyolipoma in an ...

    African Journals Online (AJOL)

    Abstract. We describe a case of renal cell carcinoma in the right kidney together with an angiomyolipoma in the left kidney, encountered in an adolescent girl at Potchefstroom Provincial Hospital, North West Province, South Africa.

  16. Radiographic and radionuclide lung perfusion imaging in healthy calves and calves naturally infected with bovine respiratory syncytial virus

    International Nuclear Information System (INIS)

    Verhoeff, J.; Brom, W.E. van den; Ingh, T.S.G.A.M. van den

    1992-01-01

    Nine calves between three and 18 weeks old with serologically confirmed natural bovine respiratory syncytial virus infection were examined clinically, radiographically and by radionuclide lung perfusion imaging. The results were compared with those from seven healthy calves. The diseased calves were euthanased and examined pathologically, virologically and bacteriologically. The clinical signs indicated that the disease was in an acute stage. Radiography of the diseased animals revealed cysts, corresponding morphologically with bullous emphysema, and infiltrations roughly corresponding in distribution with atelectatic and, or, pneumonic areas. Radionuclide lung perfusion imaging revealed no perfusion shifts between the left and right lungs and a normal perfusion pattern in five of the nine diseased calves. The abnormalities in the perfusion patterns of three calves were probably caused by anatomical disorders such as cysts and pleural adhesions, but no cause of the abnormality could be found in one calf. These findings suggest that in calves infected with bovine respiratory syncytial virus, the normal perfusion pattern is maintained until anatomical disorders occur. The pathological examination and radiography revealed that the cranioventral lung fields were particularly poorly ventilated. This finding and the normal perfusion pattern indicate that these parts of the lungs are probably the sites where shuntings and perfusion-ventilation mismatchings occur

  17. Valutazione morfo-funzionale in pazienti ipertesi con stenosi dell'arteria renale

    International Nuclear Information System (INIS)

    Cuocolo, A.; Celentano, L.; Nappi, A.; Neumann, R.D.; Salvatore, M.

    1991-01-01

    Renovascula hypertension is the most important and common cause of secondary hypertension. We studied 10 patients with arterial hypertension and different degrees of renal artery stenosis to assess the usefulness of dynamic radionuclide renography in evaluating renal perfusion and funcion, and to compare funcional radionuclide results to the morphological findings of renal angiography. Computer-assisted dynamic renal with 00m Tc diethylenetriaminepentaacetic acid (DTPA) and 131 I orthoiodohippurate (OIH), and renal artheriography were also employed in all patients. In all patients, radionuclide results matched angiography findings in quality. In particular, 3 patients with hemodynamical insignificant renal artery stenosis exhibited normal perfusion and function at dynamic radionuclide renography. Seven patients had significant renal artery stenosis and associated functional changes at dynamic radionuclide renography. Quantitative comparison of all patients showed a significant correlation (r=0.866, p<0.001) between the degree of renal artery stenosis, quantified as the percentage of narrowing as compared to adjacent/contralateral normal vessel diameter, and the results of split renal function, as assessed during OIH studies and expressed per kidney as a percentage of the net total counts of both kidneys. In conclusion, our results demonstrated dynamic radionuclide renography to be a valuable secondary to renal artery stenosis in hypertensive patients, providing complementary results to arteriography

  18. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro (Nagoya Univ. (Japan). Faculty of Medicine)

    1983-12-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy.

  19. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro

    1983-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy. (author)

  20. A pattern of cerebral perfusion anomalies between Major Depressive Disorder and Hashimoto Thyroiditis

    Science.gov (United States)

    2011-01-01

    Background This study aims to evaluate relationship between three different clinical conditions: Major Depressive Disorders (MDD), Hashimoto Thyroiditis (HT) and reduction in regional Cerebral Blood Flow (rCBF) in order to explore the possibility that patients with HT and MDD have specific pattern(s) of cerebral perfusion. Methods Design: Analysis of data derived from two separate data banks. Sample: 54 subjects, 32 with HT (29 women, mean age 38.8 ± 13.9); 22 without HT (19 women, mean age 36.5 ± 12.25). Assessment: Psychiatric diagnosis was carried out by Simplified Composite International Diagnostic Interview (CIDIS) using DSM-IV categories; cerebral perfusion was measured by 99 mTc-ECD SPECT. Statistical analysis was done through logistic regression. Results MDD appears to be associated with left frontal hypoperfusion, left temporal hypoperfusion, diffuse hypoperfusion and parietal perfusion asymmetry. A statistically significant association between parietal perfusion asymmetry and MDD was found only in the HT group. Conclusion In HT, MDD is characterized by a parietal flow asymmetry. However, the specificity of rCBF in MDD with HT should be confirmed in a control sample with consideration for other health conditions. Moreover, this should be investigated with a longitudinally designed study in order to determine a possible pathogenic cause. Future studies with a much larger sample size should clarify whether a particular perfusion pattern is associated with a specific course or symptom cluster of MDD. PMID:21910915

  1. [Anatomy character of renal artery and treatment of living-donor renal transplantation].

    Science.gov (United States)

    Zhang, Lei; Fei, Ji-guang; Chen, Li-zhong; Wang, Chang-xi; Deng, Su-xiong; Qiu, Jiang; Li, Jun; Chen, Guo-dong; Huang, Gang

    2009-12-15

    To study the anatomy characters of renal artery and the treatment of multiple arteries in living donor renal grafts. Records of 142 living donors were analyzed in our center. We analyzed the anatomic structure of renal arteries by DSA and CTA pre-transplantation. Thirty-one kidneys with multiple arteries were transplanted after reconstruction. Then clinical effects were compared between multiple-renal-arteries group (n=31) and single-renal-artery group (n=111). The incidence of multiple renal artery was 30.99%, and there was no difference between both sides (left kidney 22.54%, right kidney 22.13%). If the multiple artery occurred in left or right kidney, the incidence of the multiple artery occurred in the other side was 56.25% and 60.00%, respectively. The diameter of left main renal artery was more magnanimous (P=0.001) and the first branch was more closed to abdominal aorta (P=0.004). Operation time and warm/cool ischemia time were longer in the multiple-renal-arteries group. However, estimated blood loss, delayed graft function, acute rejection and flow rate of arcuate artery were similar in both groups, the same as serum creatinine and serum creatinine clearance rate on day 7, 1 month and 3 month post-operation. It was shown by repeated measures ANOVA that graft with multiple arteries didn't affect the tendency of renal function at early time post-operation. Comprehending the character of renal artery and accurate treatment of multiple artery anastomosis are critical for the effect of the living kidney transplantation.

  2. Preterm Delivery in the Setting of Left Calyceal Rupture

    Directory of Open Access Journals (Sweden)

    Brent Hanson

    2015-01-01

    Full Text Available Spontaneous rupture of the renal collecting system is a rare but serious complication of pregnancy. We report a case of nontraumatic left renal calyceal rupture in a pregnancy which ultimately progressed to preterm delivery. A 29-year-old primigravida with a remote history of urolithiasis presented with left flank pain, suprapubic pain, and signs of preterm labor at 33 weeks of gestation. The patient was believed to have urolithiasis, although initial renal ultrasound failed to demonstrate definitive calculi. After a temporary improvement in flank pain with medication, the patient experienced acute worsening of her left flank pain. Urology was consulted and further imaging was obtained. Magnetic resonance imaging (MRI was consistent with bilateral hydronephrosis and rupture of the left renal calyx. Given the patient’s worsening pain in the setting of left calyceal rupture, the urology team planned for placement of a left ureteral stent. However, before the patient could receive her stent, she progressed to active labor and delivered a viable female infant vaginally. Following delivery, the patient’s flank pain resolved rapidly and spontaneously, so no surgical intervention was performed. A summary of the literature and the details of this specific clinical situation are provided.

  3. Discrepancy between microsphere and diffusible tracer estimates of perfusion to ischemic myocardium

    International Nuclear Information System (INIS)

    Yoshida, S.; Akizuki, S.; Gowski, D.; Downey, J.M.

    1985-01-01

    This study critically tests the ability of microspheres to accurately measure perfusion to ischemic myocardium. The left anterior descending coronary artery was cannulated and perfused with arterial blood. The perfusion line was clamped, and a sidearm between the clamp and the cannula was opened to the atmosphere, allowing blood to flow retrograde from the distal segment of the artery. Measurement of regional blood flow during retrograde flow diversion with 15-micron microspheres revealed essentially zero flow to the perfused segment (0.005 ml X min-1 X g-1). Measurements under the same conditions by either 86 Rb uptake or 133 Xe washout revealed that an appreciable perfusion of the tissue persisted during retrograde flow diversion (0.043 and 0.11 ml X min-1 X g-1, respectively, for the 2 methods). Thus, the authors have identified a condition during which microspheres indicate zero flow to the tissue but diffusible tracers can both be washed in and washed out at a brisk rate. They conclude that with simple occlusion there is a hidden component of perfusion to an ischemic zone that cannot be measured by microspheres, causing them to underestimate flow by about 25% in that condition

  4. Brain perfusion SPECT correlates with CSF biomarkers in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Habert, Marie-Odile [UMR-S 678, Universite Pierre et Marie Curie-Paris 6, INSERM, Paris (France); CHU Pitie-Salpetriere, AP-HP, Department of Nuclear Medicine, Paris (France); Hopital Pitie-Salpetriere, Department of Nuclear Medicine, Paris (France); Souza, Leonardo Cruz de; Dubois, Bruno; Sarazin, Marie [CHU Pitie-Salpetriere, AP-HP, Research and Resource Memory Centre and INSERM U610, Paris (France); Lamari, Foudil; Jardel, Claude [CHU Pitie-Salpetriere, AP-HP, Department of Metabolic Biochemistry, Paris (France); Daragon, Nelle; Desarnaud, Serge [CHU Pitie-Salpetriere, AP-HP, Department of Nuclear Medicine, Paris (France)

    2010-03-15

    Our aim was to study the correlations between cerebrospinal fluid (CSF) biomarker levels such as {beta}-amyloid 42 (A{beta}{sub 42}), total and phosphorylated tau protein (T-tau and P-tau) and brain perfusion SPECT in Alzheimer's disease (AD) using a voxel-based methodology. Patients (n = 31) with clinical features of AD (n = 25) or amnestic mild cognitive impairment (aMCI) (n = 6) were retrospectively included. All subjects underwent the same clinical, neuropsychological and neuroimaging tests. They had a lumbar puncture and a brain perfusion ({sup 99m}Tc-ECD) SPECT within a time interval of 10 ({+-}26) days. Correlations between CSF biomarker concentrations and perfusion were studied using SPM2 software. Individual normalised regional activity values were extracted from the eligible clusters for calculation of correlation coefficients. No significant correlation was found between A{beta}{sub 42} concentrations and brain perfusion. A significant correlation (p < 0.01, corrected) was found between T-tau or P-tau concentrations and perfusion in the left parietal cortex. Our results suggest a strong correlation between T-tau and P-tau levels and decreased brain perfusion in regions typically affected by neuropathological changes in AD. (orig.)

  5. Selective cerebro-myocardial perfusion in complex congenital aortic arch pathology: a novel technique.

    Science.gov (United States)

    De Rita, Fabrizio; Lucchese, Gianluca; Barozzi, Luca; Menon, Tiziano; Faggian, Giuseppe; Mazzucco, Alessandro; Luciani, Giovanni Battista

    2011-11-01

    Simultaneous cerebro-myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex or recurrent aortic arch lesions. From April 2008 to April 2011, 10 patients with arch pathology underwent surgery (two hypoplastic left heart syndrome [HLHS], four recurrent arch obstruction, two aortic arch hypoplasia + ventricular septal defect [VSD], one single ventricle + transposition of the great arteries + arch hypoplasia, one interrupted aortic arch type B + VSD). Median age was 63 days (6 days-36 years) and median weight 4.0 kg (1.6-52). Via midline sternotomy, an arterial cannula (6 or 8 Fr for infants) was directly inserted into the innominate artery or through a polytetrafluoroethylene (PTFE) graft (for neonates cerebro-myocardial perfusion was 39 ± 18 min (17-69). Weaning from cardiopulmonary bypass was achieved without inotropic support in three and with low dose in seven patients. One patient required veno-arterial extracorporeal membrane oxygenation. Four patients, body weight cerebro-myocardial perfusion is feasible in patients with complex or recurrent aortic arch disease, starting from premature newborn less than 2.0 kg of body weight to adults. The technique is as safe as previously reported methods of cerebro-myocardial perfusion and possibly more versatile. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Pulmonary O2 transfer during pulsatile and non-pulsatile perfusion.

    Science.gov (United States)

    Hauge, A; Nicolaysen, G

    1980-07-01

    The importance of the perfusion pattern for the oxygen transfer has been examined in isolated rabbit lungs perfused with plasma at constant volume inflow. The lungs were ventilated with constant tidal volume and constant end-expiratory pressure. Following a standardized rise in FIO2 the rate of rise in pulmonary venous PO2 (delta PO2/delta t) was measured during alternately pulsatile and non-pulsatile perfusion in normal lungs and in lungs made edematous by elevation of left atrial pressure. In normal lungs there was no difference in delta PO2/delta t when the two modes of perfusion were compared. In edematous lungs delta PO/delta t was statistically higher during pulsatile perfusion, indicating a beneficial effect of flow- and pressure pulsations, e.g. a better distribution of V/Q ratios throughout the lungs. In a separate series of expts. the advancement of a high O2 front through the airways was measured, and the two perfusion patterns compared. Since no difference was found, we suggest that the phenomenon of "cardiogenic gas mixing" in the airways in vivo is a result of a direct action of the heart on the lungs rather than arterial pulsations.

  7. Hyperventilation, cerebral perfusion, and syncope

    DEFF Research Database (Denmark)

    Immink, R V; Pott, F C; Secher, N H

    2014-01-01

    dioxide (PaCO2) and oxygen (PaO2) partial pressures so that hypercapnia/hypoxia increases and hypocapnia/hyperoxia reduces global cerebral blood flow. Cerebral hypoperfusion and TLOC have been associated with hypocapnia related to HV. Notwithstanding pronounced cerebrovascular effects of PaCO2...... the contribution of a low PaCO2 to the early postural reduction in middle cerebral artery blood velocity is transient. HV together with postural stress does not reduce cerebral perfusion to such an extent that TLOC develops. However when HV is combined with cardiovascular stressors like cold immersion or reduced...... cardiac output brain perfusion becomes jeopardized. Whether, in patients with cardiovascular disease and/or defect, cerebral blood flow cerebral control HV-induced hypocapnia elicits cerebral hypoperfusion, leading to TLOC, remains to be established....

  8. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...... turbo-FLASH (fast low-angle shot) sequence and Gd-DTPA has been presented. Here, an extension of the model is presented taking into account fast and slow water exchange between the compartments, enabling the calculation of the unidirectional influx constant (Ki) for Gd-DTPA, the distribution volume...... of Gd-DTPA (lambda), the vascular blood volume (Vb), and the time delay through the coronary arteries (delta T). The model was evaluated by computer simulation and used on experimental results from seven healthy subjects. The results in the healthy volunteers for a region of interest placed...

  9. Renal candidiasis

    International Nuclear Information System (INIS)

    Khanna, S.; Malik, N.; Khandelwal, N.

    1990-01-01

    Most fungal infections of the urinary tract are caused by Candida albicans, a yeast-like saprophytic fungus which may become apathogen under various conditions which lower the host resistance. The use of computed tomography in the diagnosis of renal fungus balls is the subject of this communication with emphasis on the radiologists role in the recognition of this entity. (H.W.). 6 refs.; 2 figs

  10. Simultaneous maximal exercise radionuclide angiography and thallium stress perfusion imaging

    International Nuclear Information System (INIS)

    Narahara, K.A.; Mena, I.; Maublant, J.C.; Brizendine, M.; Criley, J.M.

    1984-01-01

    Gold-195m is a new ultra-short-lived radionuclide that can be used for cardiac studies. Accurate, reproducible ejection fraction and ventricular wall motion studies can be obtained from first-transit angiography using commercially available imaging and image-processing equipment. The short half-life of gold-195m (30.5 seconds) makes simultaneous dual isotope imaging possible and substantially reduces the radiation exposure from the isotope angiography. The feasibility and possible benefits of performing dual radionuclide studies were evaluated during a single exercise stress test in 24 subjects with known coronary artery disease (CAD) and in 20 normal volunteers. High-quality first-transit angiograms were obtained in all subjects. An 83% sensitivity and 95% specificity for detecting CAD with thallium-201 imaging was noted in this investigation, suggesting that its diagnostic accuracy was not altered by simultaneous dual isotone imaging. When segmental left ventricular (LV) wall motion was compared with thallium-201 perfusion imaging, divergent results were noted in 15 of 44 subjects. An analysis of the ejection fraction (EF) results at rest and stress provided additional information that could be useful in assessing the clinical significance of such differences in segmental wall motion and perfusion. Simultaneous dual isotope imaging appears to be appropriate for situations in which both LV perfusion and function require evaluation. The use of gold-195m allows such information to be obtained from a single exercise test and can thereby reduce the cost and time required for noninvasive evaluations of patients for CAD

  11. Influence of revascularization on myocardial perfusion, metabolism and function

    International Nuclear Information System (INIS)

    Kropp, Joachim; Krois, Markus; Eichhorn, Bernd; Fehske, Wolfgang; Likungu, James; Kirchhoff, P.G.; Luederitz, Berndt; Biersack, Hans-Juergen; Knapp, F.F. Jr.

    1993-01-01

    Thirty-nine patients with coronary artery disease (CAD) were investigated with sequential SPECT-scintigraphy after administration of 200 MBq of 15-(p-[I-123]iodophenyl)pentadecanoic acid (IPPA) at peak submaximal exercise. Twenty patients underwent coronary angioplasty (PTCA) from which 14 had control coronary arteriography (CA) and left ventricular cineventriculography (LVCV). Nineteen patients underwent bypass graft surgery (ACB) and stress sonography. Semi-quantification of uptake (Up, related to perfusion) and turnover (Tr, linked to metabolism) was obtained by segmental comparison of oblique slices. About 90% of the reperfused myocardial segments in the PTCA-group and 76% in the ACB-group showed an improvement of uptake after therapy (RUp). Out of these, 50% and 66% exhibited increased turnover (RTr) after PTCA or ACB, respectively. The remaining segments had persistingly pathologic RTr indicating a dissociation of improvement of perfusion and metabolism after therapy. Pathologic RTr was highly correlated with regional wall motion abnormalities (RWMA) after therapy in both groups. In the ACB-group improvement in RTr was correlated with improved RWM at rest and stress in 86% and 92%, respectively, whereas no improvement in RTr was correlated with impared function in 100% and 52%, respectively. IPPA-studies show potential to provide information about changes of perfusion and metabolism after reperfusion and IPPA-turnover is a good predictor of the pattern of contractile function. (author)

  12. Renal hemangioma

    Directory of Open Access Journals (Sweden)

    Theodorico F. da Costa Neto

    2004-06-01

    Full Text Available INTRODUCTION: Renal hemangioma is a relatively rare benign tumor, seldom diagnosed as a cause of hematuria. CASE REPORT: A female 40-year old patient presented with continuous gross hematuria, anemia and episodic right lumbar pain, with onset about 3 months previously. The patient underwent multiple blood transfusions during her hospital stay and extensive imaging propedeutics was performed. Semi-rigid ureterorenoscopy evidenced a bleeding focus in the upper calix of the right kidney, with endoscopic treatment being unfeasible. The patient underwent right upper pole nephrectomy and presented a favorable outcome. Histopathological analysis of the surgical specimen showed that it was a renal hemangioma. COMMENTS: Imaging methods usually employed for diagnostic investigation of hematuria do not have good sensitivity for renal hemangioma. However, they are important to exclude the most frequent differential diagnoses. The ureterorenoscopy is the diagnostic method of choice and endoscopic treatment can be feasible when the lesion is accessible and electrocautery or laser are available. We emphasize the open surgical treatment as a therapeutic option upon failure of less invasive methods.

  13. Obesity and renal hemodynamics

    NARCIS (Netherlands)

    Bosma, R. J.; Krikken, J. A.; van der Heide, J. J. Homan; de Jong, P. E.; Navis, G. J.

    2006-01-01

    Obesity is a risk factor for renal damage in native kidney disease and in renal transplant recipients. Obesity is associated with several renal risk factors such as hypertension and diabetes that may convey renal risk, but obesity is also associated with an unfavorable renal hemodynamic profile

  14. Radiopharmaceuticals for renal studies

    International Nuclear Information System (INIS)

    Verdera, Silvia

    1994-01-01

    Between the diagnostic techniques using radiopharmaceuticals in nuclear medicine it find renal studies.A brief description about renal glomerular filtration(GFR) and reliability renal plasma flux (ERPF),renal blood flux measurement agents (RBF),renal scintillation agents and radiation dose estimates by organ physiology was given in this study.tabs

  15. Dosimetry in myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2011-07-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  16. Dosimetry in myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C.

    2011-01-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  17. Use of ultrafast computed tomography to quantitate regional myocardial perfusion: a preliminary report

    International Nuclear Information System (INIS)

    Rumberger, J.A.; Feiring, A.J.; Lipton, M.J.; Higgins, C.B.; Ell, S.R.; Marcus, M.L.

    1987-01-01

    The purpose of this study was to assess the potential for rapid acquisition computed axial tomography (Imatron C-100) to quantify regional myocardial perfusion. Myocardial and left ventricular cavity contrast clearance curves were constructed after injecting nonionic contrast (1 ml/kg over 2 to 3 seconds) into the inferior vena cava of six anesthetized, closed chest dogs (n = 14). Independent myocardial perfusion measurements were obtained by coincident injection of radiolabeled microspheres into the left atrium during control, intermediate and maximal myocardial vasodilation with adenosine (0.5 to 1.0 mg/kg per min, intravenously, respectively). At each flow state, 40 serial short-axis scans of the left ventricle were taken near end-diastole at the midpapillary muscle level. Contrast clearance curves were generated and analyzed from the left ventricular cavity and posterior papillary muscle regions after excluding contrast recirculation and minimizing partial volume effects. The area under the curve (gamma variate function) was determined for a region of interest placed within the left ventricular cavity. Characteristics of contrast clearance data from the posterior papillary muscle region that were evaluated included the peak myocardial opacification, area under the contrast clearance curve and a contrast clearance time defined by the full width/half maximal extent of the clearance curve. Myocardial perfusion (microspheres) ranged from 35 to 450 ml/100 g per min (mean 167 +/- 125)

  18. Renal vessel reconstruction in kidney transplantation using a polytetrafluoroethylene (PTFE) vascular graft.

    Science.gov (United States)

    Kamel, Mohamed H; Thomas, Anil A; Mohan, Ponnusamy; Hickey, David P

    2007-04-01

    We report a rare experience in reconstructing short renal vessels in kidney transplantation using polytetrafluroethylene (PTFE) vascular grafts. The short renal vessels in three kidney grafts were managed by the interposition of PTFE vascular grafts. Two grafts were from deceased donors and the third was a renal auto-transplant graft. PTFE grafts were used to lengthen short renal veins in two kidney grafts and a short renal artery in one. The warm ischaemia time was under 1 h and all kidneys functioned well post-operatively. Excellent blood perfusion in the three renal grafts was present on postoperative MAG 3 renal scan. No intra-operative or post-operative complications were encountered. In the three described patients, the use of PTFE vascular graft presented no additional morbidity to the kidney transplant operation and no post-oerative complication was related to its use. However, more data are necessary to conclude that PTFE graft can be used safely in kidney transplantation.

  19. Perfusion abnormalities in congenital and neoplastic pulmonary disease: comparison of MR perfusion and multislice CT imaging

    International Nuclear Information System (INIS)

    Boll, Daniel T.; Lewin, Jonathan S.; Young, Philip; Gilkeson, Robert C.; Siwik, Ernest S.

    2005-01-01

    The aim of this work was to assess magnetic resonance (MR) perfusion patterns of chronic, nonembolic pulmonary diseases of congenital and neoplastic origin and to compare the findings with results obtained with pulmonary, contrast-enhanced multislice computed tomography (CT) imaging to prove that congenital and neoplastic pulmonary conditions require MR imaging over the pulmonary perfusion cycle to successfully and directly detect changes in lung perfusion patterns. Twenty-five patients underwent concurrent CT and MR evaluation of chronic pulmonary diseases of congenital (n=15) or neoplastic (n=10) origin. Analysis of MR perfusion and contrast-enhanced CT datasets was realized by defining pulmonary and vascular regions of interest in corresponding positions. MR perfusion calculated time-to-peak enhancement, maximal enhancement and the area under the perfusion curve. CT datasets provided pulmonary signal-to-noise ratio measurements. Vessel centerlines of bronchial arteries were determined. Underlying perfusion type, such as pulmonary arterial or systemic arterial supply, as well as regions with significant variations in perfusion were determined statistically. Analysis of the pulmonary perfusion pattern detected pulmonary arterial supply in 19 patients; six patients showed systemic arterial supply. In pulmonary arterial perfusion, MR and multislice CT imaging consistently detected the perfusion type and regions with altered perfusion patterns. In bronchial arterial supply, MR perfusion and CT imaging showed significant perfusion differences. Patients with bronchial arterial supply had bronchial arteries ranging from 2.0 to 3.6 mm compared with submillimeter diameters in pulmonary arterial perfusion. Dynamic MR imaging of congenital and neoplastic pulmonary conditions allowed characterization of the pulmonary perfusion type. CT imaging suggested the presence of systemic arterial perfusion by visualizing hypertrophied bronchial arteries. (orig.)

  20. Anatomic variations of the renal vessels: focus on the precaval right renal artery.

    Science.gov (United States)

    Bouali, Ourdia; Labarre, David; Molinier, François; Lopez, Raphaël; Benouaich, Vincent; Lauwers, Frédéric; Moscovici, Jacques

    2012-07-01

    The aim of this study was to determine the prevalence of precaval right renal artery and to investigate the distribution of renal arteries and veins. We discuss a theory of development of renal vascular variants. We retrospectively reviewed 120 arterial phase contrast material-enhanced spiral computerized tomography scans of the abdomen (1- to 2-mm section thickness) performed during a two-month period. Forty percent of the study group (48 patients) had one artery and one vein on each side, with typical course. There was a 9.17% prevalence of precaval right renal artery: 10 patients had a lower pole accessory artery in precaval position and one patient had the main and the accessory arteries that pass anterior to the inferior vena cava. In these cases, associated variations of renal vessels were higher than in the patients without precaval artery variant. There were multiple arteries in 28.3% of the right kidneys and in 26.7% of the left ones. Variants of the right renal vein consisted in multiple veins in 20% (24 cases). We detected no case of multiple left renal veins, but we described variations of its course (circum- or retroaortic vein) in 9.17% (11 cases). Twenty-six patients (21.7%) had associated variations of the renal pedicle. The current technical support allows for a minimally invasive study of vessels anatomy. In our study the prevalence of a precaval right renal artery appears to be higher than previously reported (9.17%). Knowledge on anatomical variations of right renal artery and associated renal vessels variations has major clinical implications.

  1. Ultrasonographically determined renal values and comparisons to serum biochemistry renal variables in aged semi-captive cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Kirberger, Robert M; Tordiffe, Adrian S W

    2017-11-06

    Cheetahs in captivity have a high prevalence of chronic renal diseases. We ultrasonographically evaluated the renal volumes, a variety of renal dimensions, interarcuate artery resistive indices (RI) as well as aortic diameters and the length of the ventral aspect of the 6th lumbar vertebrae in 27 aged semi-captive anesthetized cheetahs. Renal size, dimensions and ratios were compared to urine specific gravity, serum creatinine and urea values. There were minimal differences for all values between left and right kidneys. Mean kidney length was 65.1 mm (range 55.2-76.9) with left kidney length ratios to L6 length being 1.60 (range 1.27-2.06) and to the aortic diameter 7.69 (range 4.54-10.72). Significant correlations between left renal length as well as length:L6 ratio to creatinine values were found ((r - 0.66) and (r - 0.60) respectively). The mean RI values of the different sedation/anesthetic protocols ranged from 0.46-0.55. Left renal length and L6 ventral vertebral body length as well as left kidney RI values should be routinely measured in all cheetah abdominal ultrasound examinations. These measurements, together with serum creatinine, urea and urine specific gravity values may be relatively sensitive indicators of early renal pathology in the absence of gross ultrasonographic changes.

  2. Prevalence and predictors of an abnormal stress myocardial perfusion study in asymptomatic patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Scholte, Arthur J.H.A.; Schuijf, Joanne D.; Wall, Ernst E. van der; Bax, Jeroen J.; Kharagjitsingh, Antje V.; Dibbets-Schneider, Petra; Stokkel, Marcel P.

    2009-01-01

    The purpose of this study was to evaluate the prevalence of an abnormal stress myocardial perfusion study in a cohort of truly asymptomatic patients with type 2 diabetes mellitus using myocardial perfusion imaging by means of single photon emission computed tomography (SPECT). Secondly, we determined which clinical characteristics may predict an abnormal stress myocardial perfusion study in this population. A total of 120 asymptomatic patients (mean age 53±10 years) with type 2 diabetes mellitus and one or more risk factors for coronary artery disease were prospectively recruited from an outpatient diabetes clinic. All patients underwent myocardial perfusion imaging by means of adenosine 99m Tc sestamibi SPECT. Images were evaluated for the presence of perfusion abnormalities as well as other nonperfusion abnormalities that may indicate extensive ischaemia, including left ventricular dysfunction (defined as a left ventricular ejection fraction <45%), transient ischaemic dilatation and adenosine-induced ST segment depression. Multivariable analysis was performed using a backward selection strategy to identify potential predictors for an abnormal stress myocardial perfusion study. Finally, all patients were followed up for 12 months to determine the occurrence of cardiovascular events: (1) cardiac death, (2) nonfatal myocardial infarction, (3) unstable angina requiring hospitalization, (4) revascularization, or (5) stroke. Of the 120 patients, 40 (33%) had an abnormal stress study, including myocardial perfusion abnormalities in 30 patients (25%). In 10 patients (8%), indicators of extensive (possibly balanced ischaemia) were observed in the absence of abnormal perfusion. The multivariable analysis identified current smoking, duration of diabetes and the cholesterol/high-density lipoprotein (HDL) ratio as independent predictors of an abnormal stress study. During a follow-up period of 12 months six patients (5%) had a cardiovascular event. The current study revealed

  3. Comprehensive Assessment of Coronary Artery Disease by Using First-Pass Analysis Dynamic CT Perfusion: Validation in a Swine Model.

    Science.gov (United States)

    Hubbard, Logan; Lipinski, Jerry; Ziemer, Benjamin; Malkasian, Shant; Sadeghi, Bahman; Javan, Hanna; Groves, Elliott M; Dertli, Brian; Molloi, Sabee

    2018-01-01

    Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (P FPA and P MSM ) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (P MICRO ), as follows: P FPA_COMBINED = 1.02 P MICRO_COMBINED + 0.11 (r = 0.96) and P MSM_COMBINED = 0.28 P MICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.

  4. The effect of patent ductus arteriosus on pre-ductal and post-ductal perfusion index in preterm neonates.

    Science.gov (United States)

    Nitzan, Itamar; Hammerman, Cathy; Fink, Daniel; Nitzan, Meir; Koppel, Robert; Bromiker, Ruben

    2018-06-26

    The ductus arteriosus is a blood vessel that connects the pulmonary artery to the descending aorta during fetal life and generally undergoes spontaneous closure shortly after birth. In premature neonates it often fails to close (patent ductus arteriosus - PDA), which can result in diversion of a significant part of the left-ventricular cardiac output to the pulmonary circulation. This left-to-right shunt may result in significant increase of pulmonary blood flow and decrease of systemic perfusion (hemodynamically significant PDA - hsPDA), which may lead to severe neonatal morbidity. The study objective was to find the relationship between hsPDA and perfusion index (PI), a photoplethysmographic parameter, related to systemic perfusion. Approach. PI measures the relative systolic increase in tissue light absorption due to the systolic increase in the tissue blood volume. PI has been found to be directly related to tissue perfusion, and is therefore expected to be affected by hsPDA. Main results. PI was found to be higher in preterm neonates with hsPDA after first week of life, in comparison to those with closed DA, despite the lower systemic perfusion, probably due to reverse flow during diastole. Significance. In our study, perfusion index increased despite the lower systemic perfusion, indicating that in neonates with hsPDA, perfusion index is not necessarily a measure of perfusion. Nevertheless, PI can be used as a screening tool for suspicious PDA, in order to select a relatively small group of neonates for a more definitive examination by echocardiography, which is not suitable for universal screening. . © 2018 Institute of Physics and Engineering in Medicine.

  5. The role of the renal afferent and efferent nerve fibres in heart failure

    Directory of Open Access Journals (Sweden)

    Lindsea C Booth

    2015-10-01

    Full Text Available Renal nerves contain afferent, sensory and efferent, sympathetic nerve fibres. In heart failure (HF there is an increase in renal sympathetic nerve activity, which can lead to renal vasoconstriction, increased renin release and sodium retention. These changes are thought to contribute to renal dysfunction, which is predictive of poor outcome in patients with HF. In contrast, the role of the renal afferent nerves remains largely unexplored in HF. This is somewhat surprising as there are multiple triggers in HF that have the potential to increase afferent nerve activity, including increased venous pressure and reduced kidney perfusion. Some of the few studies investigating renal afferents in HF have suggested that at least the sympatho-inhibitory reno-renal reflex is blunted. In experimentally induced HF, renal denervation, both surgical and catheter-based, has been associated with some improvements in renal and cardiac function. It remains unknown whether the effects are due to removal of the efferent renal nerve fibres, afferent renal nerve fibres, or a combination of both. Here, we review the effects of HF on renal efferent and afferent nerve function and critically assess the latest evidence supporting renal denervation as a potential treatment in HF.

  6. The role of the renal afferent and efferent nerve fibers in heart failure

    Science.gov (United States)

    Booth, Lindsea C.; May, Clive N.; Yao, Song T.

    2015-01-01

    Renal nerves contain afferent, sensory and efferent, sympathetic nerve fibers. In heart failure (HF) there is an increase in renal sympathetic nerve activity (RSNA), which can lead to renal vasoconstriction, increased renin release and sodium retention. These changes are thought to contribute to renal dysfunction, which is predictive of poor outcome in patients with HF. In contrast, the role of the renal afferent nerves remains largely unexplored in HF. This is somewhat surprising as there are multiple triggers in HF that have the potential to increase afferent nerve activity, including increased venous pressure and reduced kidney perfusion. Some of the few studies investigating renal afferents in HF have suggested that at least the sympatho-inhibitory reno-renal reflex is blunted. In experimentally induced HF, renal denervation, both surgical and catheter-based, has been associated with some improvements in renal and cardiac function. It remains unknown whether the effects are due to removal of the efferent renal nerve fibers or afferent renal nerve fibers, or a combination of both. Here, we review the effects of HF on renal efferent and afferent nerve function and critically assess the latest evidence supporting renal denervation as a potential treatment in HF. PMID:26483699

  7. Idiopathic retroperitoneal fibrosis involving a unilateral renal sinus: A case report and literature review

    International Nuclear Information System (INIS)

    Lee, Seul Bi; Yoon, Jung Hee; Kim, Seung Ho; Lee, Ye Daum; Kim, Suk Jung; Lim, Yun Jung; Jung, Hyun Kyung; Lee, Jin Soo

    2016-01-01

    Idiopathic retroperitoneal fibrosis (RPF) is a rare disease entity and its etiology is uncertain. We report two similar cases which showed an uncommon presentation of idiopathic RPF. A 66-year-old woman and an 80-year-old man presented with incidental findings of left renal pelvic mass-like lesions. Computed tomography revealed a soft tissue density mass replacing the left renal pelvis, which was suspicious for renal pelvic cancer, and the diagnosis of idiopathic RPF was surgically confirmed. To the best of our knowledge, a few cases of idiopathic RPF presenting with features of a localized unilateral renal pelvic mass mimicking renal pelvic cancer have been reported

  8. Idiopathic retroperitoneal fibrosis involving a unilateral renal sinus: A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seul Bi; Yoon, Jung Hee; Kim, Seung Ho; Lee, Ye Daum; Kim, Suk Jung; Lim, Yun Jung; Jung, Hyun Kyung; Lee, Jin Soo [Dept. of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2016-06-15

    Idiopathic retroperitoneal fibrosis (RPF) is a rare disease entity and its etiology is uncertain. We report two similar cases which showed an uncommon presentation of idiopathic RPF. A 66-year-old woman and an 80-year-old man presented with incidental findings of left renal pelvic mass-like lesions. Computed tomography revealed a soft tissue density mass replacing the left renal pelvis, which was suspicious for renal pelvic cancer, and the diagnosis of idiopathic RPF was surgically confirmed. To the best of our knowledge, a few cases of idiopathic RPF presenting with features of a localized unilateral renal pelvic mass mimicking renal pelvic cancer have been reported.

  9. Extreme premature with persistent left superior vena cava.

    Science.gov (United States)

    Aboitiz-Rivera, Carlos Manuel; Blachman-Braun, Ruben; Parra-Pérez, Mariana Yazmin

    2017-10-01

    Persistent left superior vena cava (PLSVC) is a congenital anomaly, that results when there is an absence of the normal regression of the left common precardinal vein during embryogenesis. Usually, this anomaly remains asymptomatic, however, when the PLSVC drains into the left atrium this could lead to a right-to-left shunt. Additionally, this can result in inadvertent delivery of air or thrombus into the systemic circulation with potential neurologic, cardiac and renal complications. In this article, we present a case of an extreme premature Mexican newborn in which the diagnosis was made after placement of a percutaneous central venues catheter.

  10. Value of myocardial perfusion SPECT in pediatric population

    International Nuclear Information System (INIS)

    Massardo, T.; Coll, C.; Prat, H.; Gonzalez, P.; Doggenweiller, P.; Castillo, M.E.; Solis, A.

    2002-01-01

    Isotopic myocardial perfusion studies are less frequently used in children than in adults and their indications are also different. Our goal was to analyze retrospectively the experience with stress perfusion myocardial SPECT in pediatric population. Method: Since 1998 to 2001, ten studies were performed to 5 girls and 3 boys. Their mean age was 7±3 years ranging from 1-11. Three of them presented abnormal coronary arteries pre and post surgical intervention with or without coil; three had Kawasaki disease with coronary aneurysms and the other two, congenital cardiopathies (Cantrell pentalogy and great vessel transposition,both with posterior left ventricular hypokinesia post surgery). Stress was obtained using dipyridamole infusion (0.56 mg/kg) in 6 cases and treadmill exercise using Bruce protocol in 4. All those tests were well tolerated. Sestamibi Tc99m was selected in 80% of the cases and Tl 201 in the rest. Only 2 small children required anesthesia during SPECT acquisition. Results: Stress EKG did not demonstrated ischemia in any case. Coronary angiography was performed only in 50% of the patients, it was concordant with SPECT features in all, two of those patients presented transient perfusion defects (one Kawasaki and one abnormal coronary artery with a fistulae).The repaired pentalogy presented ischemia and septal infarction; in that patient echocardiographic hipokinesia was concordant with fixed hypoperfusion. One case with abnormal coronary plus mitral regurgitation (without isotopic ischemia) was submitted to embolization posteriorly, obtaining motion improvement. Clinical outcome was concordant with the presence or absence of isotopic ischemia in the rest of the patients. Conclusion: SPECT myocardial perfusion was helpful in the therapeutic approach and in prediction of outcome in children

  11. Rapid gated Thallium-201 perfusion SPECT - clinically feasible?

    International Nuclear Information System (INIS)

    Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.; Wilkinson, D.; Abatti, D.

    1998-01-01

    Full text: Standard dose energy window optimised Thallium-201 (Tl-201) SPECT has about half the counts of a standard dose from Technetium-99m Sestamibi (Tc99m-Mibi) gated perfusion SPECT. This study investigates the clinical feasibility of rapid energy window optimised Tl-201 gated perfusion SPECT (gated-TI) and compares quantitative left ventricular ejection fraction (LVEF) and visually assessed image quality for wall motion and thickening to analogous values obtained from Tc99m-Mibi gated perfusion SPECT (gated - mibi). Methods: We studied 60 patients with a rest gated Tl-201 SPECT (100 MBq, 77KeV peak, 34% window, 20 sec/projection) followed by a post stress gated Sestamibi SPECT (1GBq, 140KeV, 20% window, 20 sec/projection) separate dual isotope protocol. LVEF quantitation was performed using commercially available software (SPECTEF, General Electric). Visual grading of image quality for wall thickening and motion was performed using a three-point scale (excellent, good and poor). Results: LVEF for gated Tl-201 SPECT was 59.6 ± 12.0% (Mean ± SD). LVEF for gated Sestamibi SPECT was 60.4 ±11.4% (Mean ± SD). These were not significantly different (P=0.27, T-Test). There was good correlation (r=0.9) between gated-TI and gated-mibi LVEF values. The quality of gated-Tl images was ranked as excellent, good and poor in 12, 50 and 38% of the patients respectively. Image quality was better in gated-mibi SPECT, with ratings of 12, 62 and 26% respectively. Conclusion: Rapid gated Thallium-201 acquisition with energy window optimisation can be effectively performed on majority of patients and offers the opportunity to assess not only myocardial perfusion and function, as with Technetium based agents, but also viability using a single day one isotope protocol

  12. Preliminary application of brain perfusion SPECT imaging in schizophrenia

    International Nuclear Information System (INIS)

    Wu Zhixing; Guo Chanliu; Li Xingbao; Liang Rongxiang; Zhao Jun; Yan Tingxiu

    1996-01-01

    The clinical value of 99m Tc-ECD brain perfusion SPECT imaging was evaluated in patients with schizophrenia. 32 patients with schizophrenia and 21 normal controls were analyzed with 99m Tc-ECD SPECT. 93.8% (30/32) of the patients showed decreased regional cerebral blood flow (rCBF). There was normal rCBF in controls. In the patient group rCBF decreased significantly in bilateral frontal lobes, left temporal lobe and right basal ganglion. The rCBF of left temporal lobe was significantly lower than that of right temporal lobe. The decreasing rCBF was not significantly related to previous treatment and duration of illness. 99m Tc-ECD SPECT is useful for the study and diagnosis of patients with schizophrenia

  13. Angiography in renal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Doo Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Angiographies on forty cases of renal tuberculosis performed at the National Medical Center during a period 1960 through 1970 were reviewed. Abdominal angiography was performed via the femoral route. Some were followed by selective nephroangiography. All patients were subjected to urographyior to angiography. The results of X-ray findings in the forty cases with renal tuberculosis were follows. 1. The age varied 18 to 57 years, average 30.5 years. Twenty one patients were male, and nineteen were female. 2. The right kidney was involved in 17 cases and the left in 15 cases. Both kidneys were involved in 8 cases. 3. Urographic examination revealed pathologic changes in all patients. 4. Focal destruction in the collecting system was the most common finding in the urography of 16 patients. 5. A varying degree of hydronephrosis was present in 15 patients, of whom nine had complained of palpable mass due to hydronephrosis. 6. In the 7 patients with extensive destruction there was no observable excretion contrast medium from the diseased kidney. 7. Angiographic examination was normal in 6 of the 40 patients. 8. Decreased vascularity in the subsegmental or smaller arteries of the affected kidney was the most frequent finding, being found in 34 patients. 9. Occlusion or abrupt termination of the subsegmental arteries was present in 4 patients. 10. Eighteen of the patients had signs of an expansive process within the cavity, the vessels being displaced and stretched around the lesions.

  14. External carotid compression: a novel technique to improve cerebral perfusion during selective antegrade cerebral perfusion for aortic arch surgery.

    Science.gov (United States)

    Grocott, Hilary P; Ambrose, Emma; Moon, Mike

    2016-10-01

    Selective antegrade cerebral perfusion (SACP) involving cannulation of either the axillary or innominate artery is a commonly used technique for maintaining cerebral blood flow (CBF) during the use of hypothermic cardiac arrest (HCA) for operations on the aortic arch. Ne