WorldWideScience

Sample records for left eye scans

  1. Advantages in exploring a new environment with the left eye in lizards.

    Science.gov (United States)

    Bonati, Beatrice; Csermely, Davide; Sovrano, Valeria Anna

    2013-07-01

    Lizards (Podarcis muralis) preferentially use the left eye during spatial exploration in a binocular condition. Here we allowed 44 adult wild lizards to explore an unknown maze for 20 min under a temporary monocular condition whilst recording their movements, particularly the direction of turns made whilst walking within the maze. Lizards with a patch on their right eye, i.e. using their left eye to monitor the environment, moved faster than lizards with a patch on their left eye when turning both leftward and rightward in a T-cross. Hence, right eye-patched lizards were faster than left eye-patched lizards also in turning right, although their right eye was covered. Thus, lizards that could use the left eye/right hemisphere to attend spatial cues appeared to have more control and to be more prompt in exploring the maze. In addition, female lizards with their left eye covered stopped very frequently when they reached crosses, showing a high level of indecision. Results confirm that P. muralis lizards using their left eye only in exploring a new environment react faster and more efficiently than those using the right eye only in exploration. Hence lateralisation of spatial stimuli mediated by the left eye/right hemisphere could provide an advantage to this species. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Looking at a predator with the left or right eye: asymmetry of response in lizards.

    Science.gov (United States)

    Bonati, Beatrice; Csermely, Davide; Sovrano, Valeria Anna

    2013-01-01

    Studies carried out with the common wall lizard (Podarcis muralis) revealed preferential use of the left eye during responses to predatory threat in laboratory settings and in the wild. Here we tested lizards under monocular conditions of vision, using temporary eye-patching. Lizards were facing a (simulated) predatory threat laterally, from the side of the non-patched eye. Results showed that lizards with the left eye uncovered during predatory threat used the left eye to monitor the predator, whereas lizards with the right eye uncovered nonetheless tried to use the covered left eye. Moreover, lizards frequently tried to change the eye exposition, making a body C-bend behaviour. Right-eyed lizards showed more frequent and faster C-bending responses than left-eyed lizards, trying to monitor the predator with the left eye even though it was patched. Results fit with asymmetries in spontaneous eye use observed in laboratory conditions and in the wild in this species, confirming that structures located on the right side of the brain (mainly served by the left eye) predominantly attend to predatory threat.

  3. Increased prevalences of left-handedness and left-eye sighting dominance in individuals with Williams-Beuren syndrome

    NARCIS (Netherlands)

    J.W. van Strien (Jan)

    2005-01-01

    textabstractHandedness and eye sighting dominance were assessed in a sample of 50 individuals (25 male, 25 female; aged 5 – 38 years) with Williams-Beuren syndrome (WBS). The prevalences of left-handedness and left-eyedness were compared to the normative prevalences in the general population. We

  4. Basal ganglia neuronal activity during scanning eye movements in Parkinson's disease.

    Directory of Open Access Journals (Sweden)

    Tomáš Sieger

    Full Text Available The oculomotor role of the basal ganglia has been supported by extensive evidence, although their role in scanning eye movements is poorly understood. Nineteen Parkinsońs disease patients, which underwent implantation of deep brain stimulation electrodes, were investigated with simultaneous intraoperative microelectrode recordings and single channel electrooculography in a scanning eye movement task by viewing a series of colored pictures selected from the International Affective Picture System. Four patients additionally underwent a visually guided saccade task. Microelectrode recordings were analyzed selectively from the subthalamic nucleus, substantia nigra pars reticulata and from the globus pallidus by the WaveClus program which allowed for detection and sorting of individual neurons. The relationship between neuronal firing rate and eye movements was studied by crosscorrelation analysis. Out of 183 neurons that were detected, 130 were found in the subthalamic nucleus, 30 in the substantia nigra and 23 in the globus pallidus. Twenty percent of the neurons in each of these structures showed eye movement-related activity. Neurons related to scanning eye movements were mostly unrelated to the visually guided saccades. We conclude that a relatively large number of basal ganglia neurons are involved in eye motion control. Surprisingly, neurons related to scanning eye movements differed from neurons activated during saccades suggesting functional specialization and segregation of both systems for eye movement control.

  5. Basal ganglia neuronal activity during scanning eye movements in Parkinson's disease.

    Science.gov (United States)

    Sieger, Tomáš; Bonnet, Cecilia; Serranová, Tereza; Wild, Jiří; Novák, Daniel; Růžička, Filip; Urgošík, Dušan; Růžička, Evžen; Gaymard, Bertrand; Jech, Robert

    2013-01-01

    The oculomotor role of the basal ganglia has been supported by extensive evidence, although their role in scanning eye movements is poorly understood. Nineteen Parkinsońs disease patients, which underwent implantation of deep brain stimulation electrodes, were investigated with simultaneous intraoperative microelectrode recordings and single channel electrooculography in a scanning eye movement task by viewing a series of colored pictures selected from the International Affective Picture System. Four patients additionally underwent a visually guided saccade task. Microelectrode recordings were analyzed selectively from the subthalamic nucleus, substantia nigra pars reticulata and from the globus pallidus by the WaveClus program which allowed for detection and sorting of individual neurons. The relationship between neuronal firing rate and eye movements was studied by crosscorrelation analysis. Out of 183 neurons that were detected, 130 were found in the subthalamic nucleus, 30 in the substantia nigra and 23 in the globus pallidus. Twenty percent of the neurons in each of these structures showed eye movement-related activity. Neurons related to scanning eye movements were mostly unrelated to the visually guided saccades. We conclude that a relatively large number of basal ganglia neurons are involved in eye motion control. Surprisingly, neurons related to scanning eye movements differed from neurons activated during saccades suggesting functional specialization and segregation of both systems for eye movement control.

  6. The bird's-eye views of the whole body bone scans

    Energy Technology Data Exchange (ETDEWEB)

    Machida, K; Akaike, A; Hayashi, S; Watari, T; Yasukochi, H [Tokyo Univ. (Japan). Faculty of Medicine

    1975-07-01

    Using a newly developed whole body gamma scanner (Toshiba-RDA-601), the authors recorded whole body bone scans in 5 patients (two normal, osteomalacia, bone metastases of prostate cancer and bone metastases of breast cancer), and compared the regular scintiscans with those of bird's-eye view images which were made with the data processor of the scanner. The scans were started about 2 hours after intravenous injection of 3 to 8 mCi of sup(99m)Tc-monofluorophosphate stannous fluoride. The recorded bird's-eye view scans displayed the skeletal system vividly as they were, and the distribution of radioactivity semiquantitatively. It was concluded that the bird'eye view scan is superior to the regular scan, in view of the point that it expresses the distribution of radioactivity semiquantitatively and enables one to know the amount of abnormally accumulated radioactivities by measuring the height of the peak of the diseased area, although this is very difficult in the regular scan. More clinical studies are needed in order to determine which is better for detecting abnormal part clinically.

  7. Longitudinal strain bull's eye plot patterns in patients with cardiomyopathy and concentric left ventricular hypertrophy.

    Science.gov (United States)

    Liu, Dan; Hu, Kai; Nordbeck, Peter; Ertl, Georg; Störk, Stefan; Weidemann, Frank

    2016-05-10

    Despite substantial advances in the imaging techniques and pathophysiological understanding over the last decades, identification of the underlying causes of left ventricular hypertrophy by means of echocardiographic examination remains a challenge in current clinical practice. The longitudinal strain bull's eye plot derived from 2D speckle tracking imaging offers an intuitive visual overview of the global and regional left ventricular myocardial function in a single diagram. The bull's eye mapping is clinically feasible and the plot patterns could provide clues to the etiology of cardiomyopathies. The present review summarizes the longitudinal strain, bull's eye plot features in patients with various cardiomyopathies and concentric left ventricular hypertrophy and the bull's eye plot features might serve as one of the cardiac workup steps on evaluating patients with left ventricular hypertrophy.

  8. The central retinal artery occlusion in the right eye followed by a branch retinal artery occlusion in the left eye four days later

    Directory of Open Access Journals (Sweden)

    Cagatay Caglar

    2013-01-01

    Full Text Available A 65-year-old woman was admitted to our clinic with complaints of sudden, painless, decrease in vision, and sectoral visual field defect in the left eye and later presented to our clinic again with a history of sudden loss of vision in her right eye. In this case study we reported that the patient had branch retinal artery occlusion (BRAO in the left eye and at the same time progressing central retinal artery occlusion (CRAO in the right eye.

  9. Eye scanning activity influenced by temperament traits

    Czech Academy of Sciences Publication Activity Database

    Lukavský, Jiří

    2005-01-01

    Roč. 34, - (2005), s. 121 ISSN 0301-0066. [European Conference on Visual Perception 2005. 22.08.2005-26.08.2005] Institutional research plan: CEZ:AV0Z70250504 Keywords : Eye movements * scanning * temperament * TCI-R * Rorschach test Subject RIV: AN - Psychology

  10. Scanning mid-IR laser apparatus with eye tracking for refractive surgery

    Science.gov (United States)

    Telfair, William B.; Yoder, Paul R., Jr.; Bekker, Carsten; Hoffman, Hanna J.; Jensen, Eric F.

    1999-06-01

    A robust, real-time, dynamic eye tracker has been integrated with the short pulse mid-infrared laser scanning delivery system previously described. This system employs a Q- switched Nd:YAG laser pumped optical parametric oscillator operating at 2.94 micrometers. Previous ablation studies on human cadaver eyes and in-vivo cat eyes demonstrated very smooth ablations with extremely low damage levels similar to results with an excimer. A 4-month healing study with cats indicated no adverse healing effects. In order to treat human eyes, the tracker is required because the eyes move during the procedure due to both voluntary and involuntary motions such as breathing, heartbeat, drift, loss of fixation, saccades and microsaccades. Eye tracking techniques from the literature were compared. A limbus tracking system was best for this application. Temporal and spectral filtering techniques were implemented to reduce tracking errors, reject stray light, and increase signal to noise ratio. The expanded-capability system (IRVision AccuScan 2000 Laser System) has been tested in the lab on simulated eye targets, glass eyes, cadaver eyes, and live human subjects. Circular targets ranging from 10-mm to 14-mm diameter were successfully tracked. The tracker performed beyond expectations while the system performed myopic photorefractive keratectomy procedures on several legally blind human subjects.

  11. Leptomeningeal angiomatosis of the left occipital surface detected by CT scan

    International Nuclear Information System (INIS)

    Niiro, Masaki; Mihara, Tadahiro; Maeda, Yoshiki; Awa, Hiroshi; Kadota, Koki; Asakura, Tetsuhiko

    1982-01-01

    A case of left occipital leptomeningeal angiomatosis was reported. The patient was a 12-year-old boy who had episodes of severe vascular type headache accompanied by transient right homonymous hemianopsia. CT scan showed localized superficial high density area in the left occipital pole. Remarkable enhancement of the lower and inner surface of the left occipital lobe was demonstrated. Angiography showed poor filling of the distal portion of the left posterior cerebral artery. Skull tomograms showed linear calcifications in the left occipital region. Brain scan showed increased RI uptake in the left occipital region. During operation, the surface of the left occipital lobe was covered by excessive, fine, vascular networks which extended over the arachnoid membrane. The abnormal vessels were cauterized by a CO 2 laser as throughly as possible. The occipital pole, felt gritty. Histologically, the abnormal vessels had spread into the subarachnoid space and were predominantly veins with thin and enlarged walls. The abnormal vessels followed the leptomeninges in the sulci of the cerebral cortex. Underneath the abnormal vessels, in the external layers of the cerebral cortex, calcium deposits were scattered and gliosis and degeneration of the ganglion cells were observed. The lesion was comparable with leptomeningeal angiomatosis. Though the pathological findings of the specimen, CT findings, and brain scan findings were extremely similar to those of Sturge-Weber disease, in this case, the typical clinical and roentgenographic findings of Sturge-Weber disease were all absent. (author)

  12. Strong rightward lateralization of the dorsal attentional network in left-handers with right sighting-eye: an evolutionary advantage.

    Science.gov (United States)

    Petit, Laurent; Zago, Laure; Mellet, Emmanuel; Jobard, Gaël; Crivello, Fabrice; Joliot, Marc; Mazoyer, Bernard; Tzourio-Mazoyer, Nathalie

    2015-03-01

    Hemispheric lateralization for spatial attention and its relationships with manual preference strength and eye preference were studied in a sample of 293 healthy individuals balanced for manual preference. Functional magnetic resonance imaging was used to map this large sample while performing visually guided saccadic eye movements. This activated a bilateral distributed cortico-subcortical network in which dorsal and ventral attentional/saccadic pathways elicited rightward asymmetrical activation depending on manual preference strength and sighting eye. While the ventral pathway showed a strong rightward asymmetry irrespective of both manual preference strength and eye preference, the dorsal frontoparietal network showed a robust rightward asymmetry in strongly left-handers, even more pronounced in left-handed subjects with a right sighting-eye. Our findings brings support to the hypothesis that the origin of the rightward hemispheric dominance for spatial attention may have a manipulo-spatial origin neither perceptual nor motor per se but rather reflecting a mechanism by which a spatial context is mapped onto the perceptual and motor activities, including the exploration of the spatial environment with eyes and hands. Within this context, strongly left-handers with a right sighting-eye may benefit from the advantage of having the same right hemispheric control of their dominant hand and visuospatial attention processing. We suggest that this phenomenon explains why left-handed right sighting-eye athletes can outperform their competitors in sporting duels and that the prehistoric and historical constancy of the left-handers ratio over the general population may relate in part on the hemispheric specialization of spatial attention. © 2014 Wiley Periodicals, Inc.

  13. The use of the eyes protection for dose reduction in CT scans of skull

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Silva, Teogenes A.; Alonso, Thessa C.

    2013-01-01

    The technique for imaging the brain scans of the skull by computed tomography (CT) scanning is the volume bounded by the foramen magnum and the apex of the skull. The lenses are radiosensitive tissues and CT scans of the head deposited significant doses on them, since they are in the region of incidence of the primary beam of X-rays. Thus, the variation of the dose deposited in the crystalline skull CT scans for diagnostic imaging of the brain was investigated. Cranial scans were performed using the acquisition protocol routine with or without the use of bismuth to shield the eyes. To carry out the scans we used a male anthropomorphic phantom, Alderson Rando model and dosimeters (TLD-100) were used to record the doses. These TLDs were used to record specific doses internally to the phantom in specific organs (crystalline, pituitary, thyroid, spinal cord and breasts). The scans were performed on a GE machine, model 64 Discovery channels. The data obtained allowed to observe the variation of dose in organs. The highest dose was recorded in the lens (26,18 mGy), followed by spinal cord (17,79 mGy). Comparing the doses of the two scans it was significant variation in the crystal. Scan using bismuth shield generated smaller doses in the eyes and in the eyes occurred the higher dose reduction, about 37%. The results may contribute to spread a suitable procedure for the optimization of CT scans of the skull

  14. Dose to the lens of the eye when scanning internal auditory meati

    International Nuclear Information System (INIS)

    English, P.T.

    1988-01-01

    With particular reference to the lens of the eye when CT scanning the internal auditory meati (IAMs), the practice of angling the scanner gantry to avoid the orbits completely justifies itself, reducing dosage to 5% of that given by a pre-orbital scan. (author)

  15. Exposure to gonads and eyes due to computerised tomography for brain scanning

    International Nuclear Information System (INIS)

    Pin-Chieh Hsu; Pao-Shan Weng; Ling-Nah Su

    1986-01-01

    Eye and gonad doses for some 150 patients were determined using thermoluminescence dosemeters. Doses received during CT scanning using a Toshiba scanner were compared with those obtained using a Pfizer scanner. A female Rando phantom was also used as the reference. For males, the average eye dose for the Toshiba was 1695+-2041 μGy per slice and the gonad dose was 2.0+-1.5 μGy per slice; for females it was 1953+-1923 μGy per slice for eyes and 0.4+-0.3 μGy per slice for gonads. (author)

  16. Determination of gonad, eye and bone marrow doses with EMI-5005 head and whole body scans

    International Nuclear Information System (INIS)

    Nishizawa, Kanae; Iwata, Takeo; Furuya, Yoshiro; Maruyama, Takashi; Hashizume, Tadashi.

    1979-01-01

    Dose determinations of tissues and organs during head and whole body scanning with an EMI computed tomographic equipment have been carried out using a Rando woman phantom. The surface dose on the phantom was measured with a Sakura lith Contact film dosimeter system. The absorbed doses in the eyes, thyroids, ovaries and the bone marrow were measured with a thermoluminescent dosimeter. The resultant surface doses for head scanning were 2.8 rad (28 mGy) per scan at maximum and 0.26 rad (2.6 mGy) per scan at minimum, and the doses for whole body scanning were 2.7 rad (27 mGy) per scan at maximum and 0.1 rad (1.0 mGy) per scan at minimum. For the complete gynecological scanning consisting of 8 slices, the eye, thyroid, ovary and the bone marrow dose was 2.4 mrad (24 μGy), 3.5 mrad (35 μGy), 500 mrad (5 mGy) and 225 mrad (2.25 mGy), respectively. And, for a typical head scanning consisting of 5 slices, the eye, thyroid, ovary and the bone marrow dose was 1400 mrad (14 mGy), 46 mrad (460 μGy), 0.60 mrad (6 μGy) and 73 mrad (730 μGy), respectively. (author)

  17. Lateralization of eye use in cuttlefish: opposite direction for anti-predatory and predatory behaviors.

    Directory of Open Access Journals (Sweden)

    Alexandra Kerstin Schnell

    2016-12-01

    Full Text Available Vertebrates with laterally placed eyes typically exhibit preferential eye use for ecological activities such as scanning for predators or prey. Processing visual information predominately through the left or right visual field has been associated with specialized function of the left and right brain. Lateralized vertebrates often share a general pattern of lateralized brain function at the population level, whereby the left hemisphere controls routine behaviors and the right hemisphere controls emergency responses. Recent studies have shown evidence of preferential eye use in some invertebrates, but whether the visual fields are predominately associated with specific ecological activities remains untested. We used the European common cuttlefish, Sepia officinalis, to investigate whether the visual field they use is the same, or different, during anti-predatory and predatory behavior. To test for lateralization of anti-predatory behavior, individual cuttlefish were placed in a new environment with opaque walls, thereby obliging them to choose which eye to orient away from the opaque wall to scan for potential predators (i.e. vigilant scanning. To test for lateralization of predatory behavior, individual cuttlefish were placed in the apex of an isosceles triangular arena and presented with two shrimp in opposite vertexes, thus requiring the cuttlefish to choose between attacking a prey item to the left or to the right of them. Cuttlefish were significantly more likely to favor the left visual field to scan for potential predators and the right visual field for prey attack. Moreover, individual cuttlefish that were leftward directed for vigilant scanning were predominately rightward directed for prey attack. Lateralized individuals also showed faster decision-making when presented with prey simultaneously. Cuttlefish appear to have opposite directions of lateralization for anti-predatory and predatory behavior, suggesting that there is functional

  18. Lateralization of Eye Use in Cuttlefish: Opposite Direction for Anti-Predatory and Predatory Behaviors.

    Science.gov (United States)

    Schnell, Alexandra K; Hanlon, Roger T; Benkada, Aïcha; Jozet-Alves, Christelle

    2016-01-01

    Vertebrates with laterally placed eyes typically exhibit preferential eye use for ecological activities such as scanning for predators or prey. Processing visual information predominately through the left or right visual field has been associated with specialized function of the left and right brain. Lateralized vertebrates often share a general pattern of lateralized brain function at the population level, whereby the left hemisphere controls routine behaviors and the right hemisphere controls emergency responses. Recent studies have shown evidence of preferential eye use in some invertebrates, but whether the visual fields are predominately associated with specific ecological activities remains untested. We used the European common cuttlefish, Sepia officinalis , to investigate whether the visual field they use is the same, or different, during anti-predatory, and predatory behavior. To test for lateralization of anti-predatory behavior, individual cuttlefish were placed in a new environment with opaque walls, thereby obliging them to choose which eye to orient away from the opaque wall to scan for potential predators (i.e., vigilant scanning). To test for lateralization of predatory behavior, individual cuttlefish were placed in the apex of an isosceles triangular arena and presented with two shrimp in opposite vertexes, thus requiring the cuttlefish to choose between attacking a prey item to the left or to the right of them. Cuttlefish were significantly more likely to favor the left visual field to scan for potential predators and the right visual field for prey attack. Moreover, individual cuttlefish that were leftward directed for vigilant scanning were predominately rightward directed for prey attack. Lateralized individuals also showed faster decision-making when presented with prey simultaneously. Cuttlefish appear to have opposite directions of lateralization for anti-predatory and predatory behavior, suggesting that there is functional specialization of

  19. Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs

    Directory of Open Access Journals (Sweden)

    Elzivânia G. Silva

    Full Text Available ABSTRACT: B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1, anterior chamber depth (M2, lens thickness (M3, lens length (M4, vitreous chamber depth (M5, optical disc length (M6 and optic nerve diameter (M7. Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS, final diastolic velocity (VDF, resistivity index (IR and pulse index (IP. No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05. The vitreous chamber depth (M5 was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05. The mean resistivity index (RI showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities

  20. MEMS scanner mirror based system for retina scanning and in eye projection

    Science.gov (United States)

    Woittennek, Franziska; Knobbe, Jens; Pügner, Tino; Dallmann, Hans-Georg; Schelinski, Uwe; Grüger, Heinrich

    2015-02-01

    Many applications could benefit from miniaturized systems to scan blood vessels behind the retina in the human eye, so called "retina scanning". This reaches from access control to sophisticated security applications and medical devices. High volume systems for consumer applications require low cost and a user friendly operation. For example this includes no need for removal of glasses and self-adjustment, in turn guidance of focus and point of attraction by simultaneous projection for the user. A new system has been designed based on the well-known resonantly driven 2-d scanner mirror of Fraunhofer IPMS. A combined NIR and VIS laser system illuminates the eye through an eye piece designed for an operating distance allowing the use of glasses and granting sufficient field of view. This usability feature was considered to be more important than highest miniaturization. The modulated VIS laser facilitates the projection of an image directly onto the retina. The backscattered light from the continuous NIR laser contains the information of the blood vessels and is detected by a highly sensitive photo diode. A demonstrational setup has been realized including readout and driving electronics. The laser power was adjusted to an eye-secure level. Additional security features were integrated. Test measurements revealed promising results. In a first demonstration application the detection of biometric pattern of the blood vessels was evaluated for issues authentication in.

  1. Measurement of effective left ventricular ejection fraction by radiocardiography associated with cardiac chamber scanning

    Energy Technology Data Exchange (ETDEWEB)

    de Vernejoul, P; Fauchet, M; Rimbert, J -N; Gambini, D; Agnely, J [Hopital Necker-Enfants-Malades, 75 - Paris (France)

    1976-03-01

    Left ventricular ejection fraction is usually measured by cineangiocardiography. When radiocardiography and cardiac chamber scanning are associated, it allows an effective left ventricular ejection fraction assessment. Ejection fractions calculated by both methods are the same in normal subjects. They are different in the case of left valvular heart disease with insufficiency. The whole regurgitation fraction can be calculated from this difference.

  2. Measurement of effective left ventricular ejection fraction by radiocardiography associated with cardiac chamber scanning

    International Nuclear Information System (INIS)

    Vernejoul, Pierre de; Fauchet, Michel; Rimbert, J.-N.; Gambini, Denis; Agnely, Jacqueline

    1976-01-01

    Left ventricular ejection fraction is usually measured by cineangiocardiography. When radiocardiography and cardiac chamber scanning are associated, it allows an effective left ventricular ejection fraction assessment. Ejection fractions calculated by both methods are the same in normal subjects. They are different in the case of left valvular heart disease with insufficiency. The whole regurgitation fraction can be calculated from this difference [fr

  3. Raccoon eyes and the MIBG super scan: scintigraphic signs of neuroblastoma in a case of suspected child abuse

    International Nuclear Information System (INIS)

    Bohdiewicz, P.J.; Gallegos, E.; Fink-Bennett, D.

    1995-01-01

    The authors report on an infant suspected of having been abused, who presented with periorbital edema and ecchymoses (clinial 'raccoon eyes'). The pattern of the nuclear medicine bone scan suggested neuroblastoma rather than trauma. Both the bone scan and the subsequent MIBG scan revealed multiple abnormalities, including markedly increased activity around the orbits, that we termed the 'scintigraphic raccoon eyes' sign. In addition, the grossly abnormal MIBG scan demonstrated avid uptake of MIBG throughout the entire skeleton with essentially complete absence of visualization of the liver and heart (the 'MIBG super scan'). These signs have not previously been described in an infant or a child with neuroblastoma. (orig.)

  4. Raccoon eyes and the MIBG super scan: scintigraphic signs of neuroblastoma in a case of suspected child abuse

    Energy Technology Data Exchange (ETDEWEB)

    Bohdiewicz, P.J. [Nuclear Medicine Dept., William Beaumont Hospital, Royal Oak, MI (United States); Gallegos, E. [Nuclear Medicine Dept., William Beaumont Hospital, Royal Oak, MI (United States); Fink-Bennett, D. [Nuclear Medicine Dept., William Beaumont Hospital, Royal Oak, MI (United States)

    1995-11-01

    The authors report on an infant suspected of having been abused, who presented with periorbital edema and ecchymoses (clinial `raccoon eyes`). The pattern of the nuclear medicine bone scan suggested neuroblastoma rather than trauma. Both the bone scan and the subsequent MIBG scan revealed multiple abnormalities, including markedly increased activity around the orbits, that we termed the `scintigraphic raccoon eyes` sign. In addition, the grossly abnormal MIBG scan demonstrated avid uptake of MIBG throughout the entire skeleton with essentially complete absence of visualization of the liver and heart (the `MIBG super scan`). These signs have not previously been described in an infant or a child with neuroblastoma. (orig.)

  5. Estimation of eye lens dose during brain scans using Gafchromic XR-QA2 film in various multidetector CT scanners

    International Nuclear Information System (INIS)

    Akhilesh, Philomina; Jamhale, Shramika H.; Sharma, S.D.; Kumar, Rajesh; Datta, D.; Kulkarni, Arti R.

    2017-01-01

    The purpose of this study was to estimate eye lens dose during brain scans in 16-, 64-, 128- and 256-slice multidetector computed tomography (CT) scanners in helical acquisition mode and to test the feasibility of using radiochromic film as eye lens dosemeter during CT scanning. Eye lens dose measurements were performed using Gafchromic XR-QA2 film on a polystyrene head phantom designed with outer dimensions equivalent to the head size of a reference Indian man. The response accuracy of XR-QA2 film was validated by using thermoluminescence dosemeters. The eye lens dose measured using XR-QA2 film on head phantom for plain brain scanning in helical mode ranged from 43.8 to 45.8 mGy. The XR-QA2 film measured dose values were in agreement with TLD measured dose values within a maximum variation of 8.9%. The good correlation between the two data sets confirms the viability of using XR-QA2 film for eye lens dosimetry. (authors)

  6. Cone structure imaged with adaptive optics scanning laser ophthalmoscopy in eyes with nonneovascular age-related macular degeneration.

    Science.gov (United States)

    Zayit-Soudry, Shiri; Duncan, Jacque L; Syed, Reema; Menghini, Moreno; Roorda, Austin J

    2013-11-15

    To evaluate cone spacing using adaptive optics scanning laser ophthalmoscopy (AOSLO) in eyes with nonneovascular AMD, and to correlate progression of AOSLO-derived cone measures with standard measures of macular structure. Adaptive optics scanning laser ophthalmoscopy images were obtained over 12 to 21 months from seven patients with AMD including four eyes with geographic atrophy (GA) and four eyes with drusen. Adaptive optics scanning laser ophthalmoscopy images were overlaid with color, infrared, and autofluorescence fundus photographs and spectral domain optical coherence tomography (SD-OCT) images to allow direct correlation of cone parameters with macular structure. Cone spacing was measured for each visit in selected regions including areas over drusen (n = 29), at GA margins (n = 14), and regions without drusen or GA (n = 13) and compared with normal, age-similar values. Adaptive optics scanning laser ophthalmoscopy imaging revealed continuous cone mosaics up to the GA edge and overlying drusen, although reduced cone reflectivity often resulted in hyporeflective AOSLO signals at these locations. Baseline cone spacing measures were normal in 13/13 unaffected regions, 26/28 drusen regions, and 12/14 GA margin regions. Although standard clinical measures showed progression of GA in all study eyes, cone spacing remained within normal ranges in most drusen regions and all GA margin regions. Adaptive optics scanning laser ophthalmoscopy provides adequate resolution for quantitative measurement of cone spacing at the margin of GA and over drusen in eyes with AMD. Although cone spacing was often normal at baseline and remained normal over time, these regions showed focal areas of decreased cone reflectivity. These findings may provide insight into the pathophysiology of AMD progression. (ClinicalTrials.gov number, NCT00254605).

  7. High-speed adaptive optics line scan confocal retinal imaging for human eye.

    Science.gov (United States)

    Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.

  8. Correlations between psychometric schizotypy, scan path length, fixations on the eyes and face recognition.

    Science.gov (United States)

    Hills, Peter J; Eaton, Elizabeth; Pake, J Michael

    2016-01-01

    Psychometric schizotypy in the general population correlates negatively with face recognition accuracy, potentially due to deficits in inhibition, social withdrawal, or eye-movement abnormalities. We report an eye-tracking face recognition study in which participants were required to match one of two faces (target and distractor) to a cue face presented immediately before. All faces could be presented with or without paraphernalia (e.g., hats, glasses, facial hair). Results showed that paraphernalia distracted participants, and that the most distracting condition was when the cue and the distractor face had paraphernalia but the target face did not, while there was no correlation between distractibility and participants' scores on the Schizotypal Personality Questionnaire (SPQ). Schizotypy was negatively correlated with proportion of time fixating on the eyes and positively correlated with not fixating on a feature. It was negatively correlated with scan path length and this variable correlated with face recognition accuracy. These results are interpreted as schizotypal traits being associated with a restricted scan path leading to face recognition deficits.

  9. The dependencies of fronto-parietal BOLD responses evoked by covert visual search suggest eye-centred coding.

    Science.gov (United States)

    Atabaki, A; Dicke, P W; Karnath, H-O; Thier, P

    2013-04-01

    Visual scenes explored covertly are initially represented in a retinal frame of reference (FOR). On the other hand, 'later' stages of the cortical network allocating spatial attention most probably use non-retinal or non-eye-centred representations as they may ease the integration of different sensory modalities for the formation of supramodal representations of space. We tested if the cortical areas involved in shifting covert attention are based on eye-centred or non-eye-centred coding by using functional magnetic resonance imaging. Subjects were scanned while detecting a target item (a regularly oriented 'L') amidst a set of distractors (rotated 'L's). The array was centred either 5° right or left of the fixation point, independent of eye-gaze orientation, the latter varied in three steps: straight relative to the head, 10° left or 10° right. A quantitative comparison of the blood-oxygen-level-dependent (BOLD) responses for the three eye-gaze orientations revealed stronger BOLD responses in the right intraparietal sulcus (IPS) and the right frontal eye field (FEF) for search in the contralateral (i.e. left) eye-centred space, independent of whether the array was located in the right or left head-centred hemispace. The left IPS showed the reverse pattern, i.e. an activation by search in the right eye-centred hemispace. In other words, the IPS and the right FEF, members of the cortical network underlying covert search, operate in an eye-centred FOR. © 2013 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.

  10. Eye Irritation Test of Bovis Calculus Pharmacopuncture Solutions for Eye Drop

    Directory of Open Access Journals (Sweden)

    Hyeong-sik Seo

    2008-06-01

    Full Text Available Objective : This study was done to investigate the safety of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods : The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration (2005. 10. 21, KFDA 2005-60. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results : 1. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn’t physical problem at 9 rabbits. 2. After Bovis Calculus pharmacopuncture solutionwas medicated in the left eye of the rabbits, there wasn’t eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions : I suggested that Bovis Calculus pharmacopuncture solution didn’t induced eye irritation in rabbits.

  11. Neural correlates of the eye dominance effect in human face perception: the left-visual-field superiority for faces revisited.

    Science.gov (United States)

    Jung, Wookyoung; Kang, Joong-Gu; Jeon, Hyeonjin; Shim, Miseon; Sun Kim, Ji; Leem, Hyun-Sung; Lee, Seung-Hwan

    2017-08-01

    Faces are processed best when they are presented in the left visual field (LVF), a phenomenon known as LVF superiority. Although one eye contributes more when perceiving faces, it is unclear how the dominant eye (DE), the eye we unconsciously use when performing a monocular task, affects face processing. Here, we examined the influence of the DE on the LVF superiority for faces using event-related potentials. Twenty left-eye-dominant (LDE group) and 23 right-eye-dominant (RDE group) participants performed the experiments. Face stimuli were randomly presented in the LVF or right visual field (RVF). The RDE group exhibited significantly larger N170 amplitudes compared with the LDE group. Faces presented in the LVF elicited N170 amplitudes that were significantly more negative in the RDE group than they were in the LDE group, whereas the amplitudes elicited by stimuli presented in the RVF were equivalent between the groups. The LVF superiority was maintained in the RDE group but not in the LDE group. Our results provide the first neural evidence of the DE's effects on the LVF superiority for faces. We propose that the RDE may be more biologically specialized for face processing. © The Author (2017). Published by Oxford University Press.

  12. Unsuccessful lung scan due to major right-to-left shunt through a sinus venosus septal defect

    International Nuclear Information System (INIS)

    Brendel, A.J.; Larnaudie, B.; Lambert, B.; Leccia, F.; Barat, J.L.; Ducassou, D.; Fontan, F.

    1985-01-01

    In a patient with a prior history of cerebral abscess and cerebral ischemia, an unsuccessful perfusion lung scan led to a radionuclide angiocardiogram using an arm vein injection. This showed a total right-to-left (R-L) shunt from the superior vena cava (SVC) to the left atrium. Repeat radionuclide study, through a leg vein, demonstrated a moderate R-L shunt and an interpretable lung scan could be obtained. Catheterization and contrast cineangiogram did not provide the exact diagnosis, the preoperative conclusion being anomalous drainage of the SVC into the left atrium, with atrial septal defect (ASD) and partial anomalous pulmonary venous connection to the SVC. The operative diagnosis was high atrial (sinus venosus) septal defect. This example of major but clinically unsuspected R-L shunt emphasizes the value of performing a perfusion lung scan, preferably in conjunction with radionuclide angiocardiography in patients with a prior history of unexplained cerebral abscess or systemic ischemia. Implications of the site of an ASD on quantitation of L-R shunts by radionuclide methods are also discussed

  13. ASSOCIATIONS BETWEEN MACULAR EDEMA AND CIRCULATORY STATUS IN EYES WITH RETINAL VEIN OCCLUSION: An Adaptive Optics Scanning Laser Ophthalmoscopy Study.

    Science.gov (United States)

    Iida, Yuto; Muraoka, Yuki; Uji, Akihito; Ooto, Sotaro; Murakami, Tomoaki; Suzuma, Kiyoshi; Tsujikawa, Akitaka; Arichika, Shigeta; Takahashi, Ayako; Miwa, Yuko; Yoshimura, Nagahisa

    2017-10-01

    To investigate associations between parafoveal microcirculatory status and foveal pathomorphology in eyes with macular edema (ME) secondary to retinal vein occlusion (RVO). Ten consecutive patients (10 eyes) with acute retinal vein occlusion were enrolled, 9 eyes of which received intravitreal ranibizumab (IVR) injections. Foveal morphologic changes were examined via optical coherence tomography (OCT), and parafoveal circulatory status was assessed via adaptive optics scanning laser ophthalmoscopy (AO-SLO). The mean parafoveal aggregated erythrocyte velocity (AEV) measured by adaptive optics scanning laser ophthalmoscopy in eyes with retinal vein occlusion was 0.99 ± 0.43 mm/second at baseline, which was significantly lower than that of age-matched healthy subjects (1.41 ± 0.28 mm/second, P = 0.042). The longitudinal adaptive optics scanning laser ophthalmoscopy examinations of each patient showed that parafoveal AEV was strongly inversely correlated with optical coherence tomography-measured central foveal thickness (CFT) over the entire observation period. Using parafoveal AEV and central foveal thickness measurements obtained at the first and second examinations, we investigated associations between differences in parafoveal AEV and central foveal thickness, which were significantly and highly correlated (r = -0.84, P = 0.002). Using adaptive optics scanning laser ophthalmoscopy in eyes with retinal vein occlusion macular edema, we could quantitatively evaluate the parafoveal AEV. A reduction or an increase in parafoveal AEV may be a clinical marker for the resolution or development/progression of macular edema respectively.

  14. Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes.

    Science.gov (United States)

    Jhanji, Vishal; Yang, Bingzhi; Yu, Marco; Ye, Cong; Leung, Christopher K S

    2013-11-01

    To compare corneal thickness and corneal elevation using swept source optical coherence tomography and slit scanning topography. Prospective study. 41 normal and 46 keratoconus subjects. All eyes were imaged using swept source optical coherence tomography and slit scanning tomography during the same visit. Mean corneal thickness and best-fit sphere measurements were compared between the instruments. Agreement of measurements between swept source optical coherence tomography and scanning slit topography was analyzed. Intra-rater reproducibility coefficient and intraclass correlation coefficient were evaluated. In normal eyes, central corneal thickness measured by swept source optical coherence tomography was thinner compared with slit scanning topography (p topography. In keratoconus eyes, central corneal thickness was thinner on swept source optical coherence tomography than slit scanning topography (p = 0.081) and ultrasound pachymetry (p = 0.001). There were significant differences between thinnest corneal thickness, and, anterior and posterior best-fit sphere measurements between both instruments (p topography. With better reproducibility coefficients and intraclass correlation coefficients, swept source optical coherence tomography may provide a reliable alternative for measurement of corneal parameters. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  15. Eye lens radiation exposure and repeated head CT scans: A problem to keep in mind

    International Nuclear Information System (INIS)

    Michel, Morgane; Jacob, Sophie; Roger, Gilles; Pelosse, Béatrice; Laurier, Dominique; Le Pointe, Hubert Ducou; Bernier, Marie-Odile

    2012-01-01

    Objectives: The deterministic character of radiation-induced cataract is being called into question, raising the possibility of a risk in patients, especially children, exposed to ionizing radiation in case of repeated head CT-scans. This study aims to estimate the eye lens doses of a pediatric population exposed to repeated head CTs and to assess the feasibility of an epidemiological study. Methods: Children treated for a cholesteatoma, who had had at least one CT-scan of the middle ear before their tenth birthday, were included. Radiation exposure has been assessed from medical records and telephone interviews. Results: Out of the 39 subjects contacted, 32 accepted to participate. A total of 76 CT-scans were retrieved from medical records. At the time of the interview (mean age: 16 years), the mean number of CT per child was 3. Cumulative mean effective and eye lens doses were 1.7 mSv and 168 mGy, respectively. Conclusion: A relatively high lens radiation dose was observed in children exposed to repeated CT-scans. Due to that exposure and despite the difficulties met when trying to reach patients’ families, a large scale epidemiological study should be performed in order to assess the risk of radiation-induced cataracts associated with repeated head CT.

  16. Clinical evaluation of a dose monitoring software tool based on Monte Carlo Simulation in assessment of eye lens doses for cranial CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Forsting, Michael; Theysohn, Jens; Wetter, Axel; Ringelstein, Adrian [University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany)

    2016-10-15

    The aim of this study was to verify the results of a dose monitoring software tool based on Monte Carlo Simulation (MCS) in assessment of eye lens doses for cranial CT scans. In cooperation with the Federal Office for Radiation Protection (Neuherberg, Germany), phantom measurements were performed with thermoluminescence dosimeters (TLD LiF:Mg,Ti) using cranial CT protocols: (I) CT angiography; (II) unenhanced, cranial CT scans with gantry angulation at a single and (III) without gantry angulation at a dual source CT scanner. Eye lens doses calculated by the dose monitoring tool based on MCS and assessed with TLDs were compared. Eye lens doses are summarized as follows: (I) CT angiography (a) MCS 7 mSv, (b) TLD 5 mSv; (II) unenhanced, cranial CT scan with gantry angulation, (c) MCS 45 mSv, (d) TLD 5 mSv; (III) unenhanced, cranial CT scan without gantry angulation (e) MCS 38 mSv, (f) TLD 35 mSv. Intermodality comparison shows an inaccurate calculation of eye lens doses in unenhanced cranial CT protocols at the single source CT scanner due to the disregard of gantry angulation. On the contrary, the dose monitoring tool showed an accurate calculation of eye lens doses at the dual source CT scanner without gantry angulation and for CT angiography examinations. The dose monitoring software tool based on MCS gave accurate estimates of eye lens doses in cranial CT protocols. However, knowledge of protocol and software specific influences is crucial for correct assessment of eye lens doses in routine clinical use. (orig.)

  17. Clinical evaluation of a dose monitoring software tool based on Monte Carlo Simulation in assessment of eye lens doses for cranial CT scans

    International Nuclear Information System (INIS)

    Guberina, Nika; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Forsting, Michael; Theysohn, Jens; Wetter, Axel; Ringelstein, Adrian

    2016-01-01

    The aim of this study was to verify the results of a dose monitoring software tool based on Monte Carlo Simulation (MCS) in assessment of eye lens doses for cranial CT scans. In cooperation with the Federal Office for Radiation Protection (Neuherberg, Germany), phantom measurements were performed with thermoluminescence dosimeters (TLD LiF:Mg,Ti) using cranial CT protocols: (I) CT angiography; (II) unenhanced, cranial CT scans with gantry angulation at a single and (III) without gantry angulation at a dual source CT scanner. Eye lens doses calculated by the dose monitoring tool based on MCS and assessed with TLDs were compared. Eye lens doses are summarized as follows: (I) CT angiography (a) MCS 7 mSv, (b) TLD 5 mSv; (II) unenhanced, cranial CT scan with gantry angulation, (c) MCS 45 mSv, (d) TLD 5 mSv; (III) unenhanced, cranial CT scan without gantry angulation (e) MCS 38 mSv, (f) TLD 35 mSv. Intermodality comparison shows an inaccurate calculation of eye lens doses in unenhanced cranial CT protocols at the single source CT scanner due to the disregard of gantry angulation. On the contrary, the dose monitoring tool showed an accurate calculation of eye lens doses at the dual source CT scanner without gantry angulation and for CT angiography examinations. The dose monitoring software tool based on MCS gave accurate estimates of eye lens doses in cranial CT protocols. However, knowledge of protocol and software specific influences is crucial for correct assessment of eye lens doses in routine clinical use. (orig.)

  18. De-warping of images and improved eye tracking for the scanning laser ophthalmoscope.

    Directory of Open Access Journals (Sweden)

    Phillip Bedggood

    Full Text Available A limitation of scanning laser ophthalmoscopy (SLO is that eye movements during the capture of each frame distort the retinal image. Various sophisticated strategies have been devised to ensure that each acquired frame can be mapped quickly and accurately onto a chosen reference frame, but such methods are blind to distortions in the reference frame itself. Here we explore a method to address this limitation in software, and demonstrate its accuracy. We used high-speed (200 fps, high-resolution (~1 μm, flood-based imaging of the human retina with adaptive optics to obtain "ground truth" information on the retinal image and motion of the eye. This information was used to simulate SLO video sequences at 20 fps, allowing us to compare various methods for eye-motion recovery and subsequent minimization of intra-frame distortion. We show that a a single frame can be near-perfectly recovered with perfect knowledge of intra-frame eye motion; b eye motion at a given time point within a frame can be accurately recovered by tracking the same strip of tissue across many frames, due to the stochastic symmetry of fixational eye movements. This approach is similar to, and easily adapted from, previously suggested strip-registration approaches; c quality of frame recovery decreases with amplitude of eye movements, however, the proposed method is affected less by this than other state-of-the-art methods and so offers even greater advantages when fixation is poor. The new method could easily be integrated into existing image processing software, and we provide an example implementation written in Matlab.

  19. Examining drivers' eye glance patterns during distracted driving: Insights from scanning randomness and glance transition matrix.

    Science.gov (United States)

    Wang, Yuan; Bao, Shan; Du, Wenjun; Ye, Zhirui; Sayer, James R

    2017-12-01

    Visual attention to the driving environment is of great importance for road safety. Eye glance behavior has been used as an indicator of distracted driving. This study examined and quantified drivers' glance patterns and features during distracted driving. Data from an existing naturalistic driving study were used. Entropy rate was calculated and used to assess the randomness associated with drivers' scanning patterns. A glance-transition proportion matrix was defined to quantity visual search patterns transitioning among four main eye glance locations while driving (i.e., forward on-road, phone, mirrors and others). All measurements were calculated within a 5s time window under both cell phone and non-cell phone use conditions. Results of the glance data analyses showed different patterns between distracted and non-distracted driving, featured by a higher entropy rate value and highly biased attention transferring between forward and phone locations during distracted driving. Drivers in general had higher number of glance transitions, and their on-road glance duration was significantly shorter during distracted driving when compared to non-distracted driving. Results suggest that drivers have a higher scanning randomness/disorder level and shift their main attention from surrounding areas towards phone area when engaging in visual-manual tasks. Drivers' visual search patterns during visual-manual distraction with a high scanning randomness and a high proportion of eye glance transitions towards the location of the phone provide insight into driver distraction detection. This will help to inform the design of in-vehicle human-machine interface/systems. Copyright © 2017. Published by Elsevier Ltd.

  20. The effects of left and right monocular viewing on hemispheric activation.

    Science.gov (United States)

    Wang, Chao; Burtis, D Brandon; Ding, Mingzhou; Mo, Jue; Williamson, John B; Heilman, Kenneth M

    2018-03-01

    Prior research has revealed that whereas activation of the left hemisphere primarily increases the activity of the parasympathetic division of the autonomic nervous system, right-hemisphere activation increases the activity of the sympathetic division. In addition, each hemisphere primarily receives retinocollicular projections from the contralateral eye. A prior study reported that pupillary dilation was greater with left- than with right-eye monocular viewing. The goal of this study was to test the alternative hypotheses that this asymmetric pupil dilation with left-eye viewing was induced by activation of the right-hemispheric-mediated sympathetic activity, versus a reduction of left-hemisphere-mediated parasympathetic activity. Thus, this study was designed to learn whether there are changes in hemispheric activation, as measured by alteration of spontaneous alpha activity, during right versus left monocular viewing. High-density electroencephalography (EEG) was recorded from healthy participants viewing a crosshair with their right, left, or both eyes. There was a significantly less alpha power over the right hemisphere's parietal-occipital area with left and binocular viewing than with right-eye monocular viewing. The greater relative reduction of right-hemisphere alpha activity during left than during right monocular viewing provides further evidence that left-eye viewing induces greater increase in right-hemisphere activation than does right-eye viewing.

  1. Relationship between eye dominance and pattern electroretinograms in normal human subjects.

    Science.gov (United States)

    Kamis, Umit; Gunduz, Kemal; Okudan, Nilsel; Gokbel, Hakki; Bodur, Sait; Tan, Uner

    2005-02-01

    The authors conducted a study in 100 non-smoker healthy normal human subjects to find a relationship between eye dominance and macular function as tested by using transient stimulus and electroretinography. Eye preference procedure was carried out using two reference points and pattern electroretinograms (PERGs) were recorded using black and white checks, each check subtending 23'. Trace averager was retriggered every 300 milliseconds (ms) with data collection time of 150 ms. The difference in PERG P50 amplitudes between right and left eyes was analyzed using Student's t test. There was no significant difference in PERG P50 amplitudes between the right and left eye dominant subjects as well as no significant differences between the right and left eyes in right eye dominants and left eye dominants, but in the left-eye dominant group the left eye PERG P50 amplitudes were significantly higher in females than males. Although pattern-reversal visual evoked potentials of healthy subjects provide electrophysiological evidence of lateralization in the nervous system, sensory eye dominance seems to have no correlation with macular function.

  2. Variable corneal compensation improves discrimination between normal and glaucomatous eyes with the scanning laser polarimeter.

    Science.gov (United States)

    Tannenbaum, Dana P; Hoffman, Douglas; Lemij, Hans G; Garway-Heath, David F; Greenfield, David S; Caprioli, Joseph

    2004-02-01

    The presently available scanning laser polarimeter (SLP) has a fixed corneal compensator (FCC) that neutralizes corneal birefringence only in eyes with birefringence that matches the population mode. A prototype variable corneal compensator (VCC) provides neutralization of individual corneal birefringence based on individual macular retardation patterns. The aim of this study was to evaluate the relative ability of the SLP with the FCC and with the VCC to discriminate between normal and glaucomatous eyes. Prospective, nonrandomized, comparative case series. Algorithm-generating set consisting of 56 normal eyes and 55 glaucomatous eyes and an independent data set consisting of 83 normal eyes and 56 glaucomatous eyes. Sixteen retardation measurements were obtained with the SLP with the FCC and the VCC from all subjects. Dependency of parameters on age, gender, ethnic origin, and eye side was sought. Logistic regression was used to evaluate how well the various parameters could detect glaucoma. Discriminant functions were generated, and the area under the receiver operating characteristic (ROC) curve was determined. Discrimination between normal and glaucomatous eyes on the basis of single parameters was significantly better with the VCC than with the FCC for 6 retardation parameters: nasal average (P = 0.0003), superior maximum (P = 0.0003), ellipse average (P = 0.002), average thickness (P = 0.003), superior average (P = 0.010), and inferior average (P = 0.010). Discriminant analysis identified the optimal combination of parameters for the FCC and for the VCC. When the discriminant functions were applied to the independent data set, areas under the ROC curve were 0.84 for the FCC and 0.90 for the VCC (PFCC and 0.90 for the VCC (P<0.016). Individual correction for corneal birefringence with the VCC significantly improved the ability of the SLP to distinguish between normal and glaucomatous eyes and enabled detection of patients with early glaucoma.

  3. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... field in oncology patients undergoing eyes-to-thighs PET/CT must always include the base of the scull according to department guidelines. The eye lens is sensitive to radiation exposure and if possible it should be avoided to scan the eye. If the patient’s head is kipped backwards during the scan one...... might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...

  4. Clinical study on left atrial thrombi. Comparative study between echocardiography and CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, E; Asano, H; Kurasawa, T; Mitsumoto, K; Yamane, Y [Tokyo Kosei-Nenkin Hospital (Japan)

    1981-09-01

    We studied left atrial thrombi (LAT) by both echocardiography and computed tomography (CT) and compared the features of the 2 methods. A total of 15 patients with mitral stenosis complicated by atrial fibrillation were selected as the subjects. LAT were noted on the M-mode echocardiograms in 2 patients including a questionably positive one, on the two-dimensional echocardiograms in 5, and on the CT scans in 6 of 15. The history of thromboembolism was rather frequent and was found in 7 of 15 patients. However, LAT was found in only 3 of these on the CT scans. A shaggy or fuzzy pattern on the M-mode echocardiogram cannot be regarded as representing thrombi, while a laminar pattern undoubtedly represented thrombi. Two-dimensional echocardiography has considerably contributed to the improved detection rate of LAT. For the characteristic properties of ultrasound beams, however, it was impossible to investigate the entire left atrium. The detection of the thrombi in the appendage was especially difficult. However, computed tomography, permitting transverse cross-sectional tomography, was capable of sectioning the heart even in the presence of air and bones. The measurement of CT values was suggestive of the properties of the substance or substances involved, and also allowed the presumption as to whether the thrombus has been fibrosed. Furthermore, it was possible to estimate more accurately as well as 3-dimensionally the location, shape and dimensions of the thrombi by the reconstruction of the heart according to the CT values. It was concluded that echocardiography and computed tomography are the mutual aid to further improvement in the detection rate of left atrial thrombi.

  5. Whole eye wavefront aberrations in Mexican male subjects.

    Science.gov (United States)

    Cantú, Roberto; Rosales, Marco A; Tepichín, Eduardo; Curioca, Andrée; Montes, Victor; Bonilla, Julio

    2004-01-01

    To analyze the characteristics, incidence, and appearance of wavefront aberrations in undilated, normal, unoperated eyes. Eighty-eight eyes of 44 healthy male Mexican subjects (mean age 25.32 years, range 18 to 36 yr) were divided into three groups based on uncorrected visual acuity of greater than or equal to 20/20, 20/30, or 20/40. UCVA measurements were obtained using an Acuity Max computer screen chart. Wavefront aberrations were measured with the Nidek OPD-Scan ARK 10000, Ver. 1.11b. All measurements were carried out at the same center by the same technician during a single session, following manufacturer instructions. Background illumination was 3 Lux. Wavefront aberration measurements for each group were statistically analyzed using StatView; an average eye was characterized and the resulting aberrations were simulated using MATLAB. We obtained wavefront aberration maps for the 20/20 undilated normal unoperated eyes for total, low, and high order aberration coefficients. Wavefront maps for right eyes were practically the same as those for left eyes. Higher aberrations did not contribute substantially to total wavefront analysis. Average aberrations of this "normal eye" will be used as criteria to decide the necessity of wavefront-guided ablation in our facilities. We will focus on the nearly zero average of high order aberrations in this normal whole eye as a reference to be matched.

  6. Eye tracking detects disconjugate eye movements associated with structural traumatic brain injury and concussion.

    Science.gov (United States)

    Samadani, Uzma; Ritlop, Robert; Reyes, Marleen; Nehrbass, Elena; Li, Meng; Lamm, Elizabeth; Schneider, Julia; Shimunov, David; Sava, Maria; Kolecki, Radek; Burris, Paige; Altomare, Lindsey; Mehmood, Talha; Smith, Theodore; Huang, Jason H; McStay, Christopher; Todd, S Rob; Qian, Meng; Kondziolka, Douglas; Wall, Stephen; Huang, Paul

    2015-04-15

    Disconjugate eye movements have been associated with traumatic brain injury since ancient times. Ocular motility dysfunction may be present in up to 90% of patients with concussion or blast injury. We developed an algorithm for eye tracking in which the Cartesian coordinates of the right and left pupils are tracked over 200 sec and compared to each other as a subject watches a short film clip moving inside an aperture on a computer screen. We prospectively eye tracked 64 normal healthy noninjured control subjects and compared findings to 75 trauma subjects with either a positive head computed tomography (CT) scan (n=13), negative head CT (n=39), or nonhead injury (n=23) to determine whether eye tracking would reveal the disconjugate gaze associated with both structural brain injury and concussion. Tracking metrics were then correlated to the clinical concussion measure Sport Concussion Assessment Tool 3 (SCAT3) in trauma patients. Five out of five measures of horizontal disconjugacy were increased in positive and negative head CT patients relative to noninjured control subjects. Only one of five vertical disconjugacy measures was significantly increased in brain-injured patients relative to controls. Linear regression analysis of all 75 trauma patients demonstrated that three metrics for horizontal disconjugacy negatively correlated with SCAT3 symptom severity score and positively correlated with total Standardized Assessment of Concussion score. Abnormal eye-tracking metrics improved over time toward baseline in brain-injured subjects observed in follow-up. Eye tracking may help quantify the severity of ocular motility disruption associated with concussion and structural brain injury.

  7. Unilateral Keratoconus after Chronic Eye Rubbing by the Nondominant Hand

    Directory of Open Access Journals (Sweden)

    Nathalie Bral

    2017-12-01

    Full Text Available Introduction: To report the development of unilateral keratoconus in a healthy male after persistent unilateral eye rubbing by the nondominant hand which was not needed for professional activities. Methods: Observational case report. Results: A 60-year-old male was first seen in our clinic due to decreased vision in his left eye. Slit-lamp biomicroscopy of the left eye revealed Vogt’s striae, stromal thinning, and a stromal scar. Corneal topography showed a stage 4 keratoconus. Clinical examination and corneal topography of the right eye were normal. Medical history revealed a habit of chronic eye rubbing only in the left eye because of the right hand being occupied for professional needs. During follow-up of 5 years, Scheimpflug images of the right eye stayed normal while the left eye showed a stable cone. Discussion: This case report supports the hypothesis of mechanical fatigue of the cornea due to repetitive shear stress on the surface caused by eye-rubbing.

  8. Adaptive optics scanning laser ophthalmoscope using liquid crystal on silicon spatial light modulator: Performance study with involuntary eye movement

    Science.gov (United States)

    Huang, Hongxin; Toyoda, Haruyoshi; Inoue, Takashi

    2017-09-01

    The performance of an adaptive optics scanning laser ophthalmoscope (AO-SLO) using a liquid crystal on silicon spatial light modulator and Shack-Hartmann wavefront sensor was investigated. The system achieved high-resolution and high-contrast images of human retinas by dynamic compensation for the aberrations in the eyes. Retinal structures such as photoreceptor cells, blood vessels, and nerve fiber bundles, as well as blood flow, could be observed in vivo. We also investigated involuntary eye movements and ascertained microsaccades and drifts using both the retinal images and the aberrations recorded simultaneously. Furthermore, we measured the interframe displacement of retinal images and found that during eye drift, the displacement has a linear relationship with the residual low-order aberration. The estimated duration and cumulative displacement of the drift were within the ranges estimated by a video tracking technique. The AO-SLO would not only be used for the early detection of eye diseases, but would also offer a new approach for involuntary eye movement research.

  9. Accuracy of the Heidelberg Spectralis in the alignment between near-infrared image and tomographic scan in a model eye: a multicenter study.

    Science.gov (United States)

    Barteselli, Giulio; Bartsch, Dirk-Uwe; Viola, Francesco; Mojana, Francesca; Pellegrini, Marco; Hartmann, Kathrin I; Benatti, Eleonora; Leicht, Simon; Ratiglia, Roberto; Staurenghi, Giovanni; Weinreb, Robert N; Freeman, William R

    2013-09-01

    To evaluate temporal changes and predictors of accuracy in the alignment between simultaneous near-infrared image and optical coherence tomography (OCT) scan on the Heidelberg Spectralis using a model eye. Laboratory investigation. After calibrating the device, 6 sites performed weekly testing of the alignment for 12 weeks using a model eye. The maximum error was compared with multiple variables to evaluate predictors of inaccurate alignment. Variables included the number of weekly scanned patients, total number of OCT scans and B-scans performed, room temperature and its variation, and working time of the scanning laser. A 4-week extension study was subsequently performed to analyze short-term changes in the alignment. The average maximum error in the alignment was 15 ± 6 μm; the greatest error was 35 μm. The error increased significantly at week 1 (P = .01), specifically after the second imaging study (P alignment were temperature variation and scans per patient (P imaging study. To improve the accuracy, room temperature should be kept stable and unnecessary scans should be avoided. The alignment of the device does not need to be checked on a regular basis in the clinical setting, but it should be checked after every other patient for more precise research purposes. Published by Elsevier Inc.

  10. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes.

    Science.gov (United States)

    Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo

    2015-01-01

    To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  11. Body-centred map in parietal eye fields - functional MRI study

    International Nuclear Information System (INIS)

    Brotchie, P.; Chen, D.Y.; Bradley, W.G.

    2002-01-01

    Full text: In order for us to interact with our environment we need to know where objects are around us, relative to our body. In monkeys, a body-centred map of visual space is known to exist within the parietal eye fields. This map is formed by the modulation of neuronal activity by eye and head position (Brotchie et al, Nature 1995; Synder et al, Nature 1998). In humans no map of body centred space has been demonstrated. By using functional MRI we have localised a region along the intraparietal sulcus which has properties similar to the parietal eye fields of monkeys (Brotchie et al, ISMRM, 2000). The aim of this study was to determine if activity in this region is modulated by head position, consistent with a body centered representation of visual space. Functional MRI was performed on 6 subjects performing simple visually guided saccades using a 1.5 Tesla GE Echospeed scanner. 10 scans were performed on the 6 subjects at left and right body orientations. Regions of interest were selected around the intraparietal sulcus proper (IPSP) of both hemispheres and voxels with BOLD signal which correlated with the paradigm (r>0.35) were selected for further analysis. Comparisons of percentage signal change were made between the left and right IPSP using Student t test. Of the 10 MRI examinations, 6 demonstrated statistically significant differences in the amount of signal change between left and right IPSP. In each of these 6 cases, the signal change was greater within the IPSP contralateral to the direction of head position relative to the body. This indicates a modulation of activity within the IPSP related to head position, most likely reflecting modulation of the underlying neuronal activity and suggests the existence of a body-centred encoding of space within the parietal eye fields of humans. Copyright (2002) Blackwell Science Pty Ltd

  12. Design validation of an eye-safe scanning aerosol lidar with the Center for Lidar and Atmospheric Sciences Students (CLASS) at Hampton University

    Science.gov (United States)

    Richter, Dale A.; Higdon, N. S.; Ponsardin, Patrick L.; Sanchez, David; Chyba, Thomas H.; Temple, Doyle A.; Gong, Wei; Battle, Russell; Edmondson, Mika; Futrell, Anne; Harper, David; Haughton, Lincoln; Johnson, Demetra; Lewis, Kyle; Payne-Baggott, Renee S.

    2002-01-01

    ITTs Advanced Engineering and Sciences Division and the Hampton University Center for Lidar and Atmospheric Sciences Students (CLASS) team have worked closely to design, fabricate and test an eye-safe, scanning aerosol-lidar system that can be safely deployed and used by students form a variety of disciplines. CLASS is a 5-year undergraduate- research training program funded by NASA to provide hands-on atmospheric-science and lidar-technology education. The system is based on a 1.5 micron, 125 mJ, 20 Hz eye-safe optical parametric oscillator (OPO) and will be used by the HU researchers and students to evaluate the biological impact of aerosols, clouds, and pollution a variety of systems issues. The system design tasks we addressed include the development of software to calculate eye-safety levels and to model lidar performance, implementation of eye-safety features in the lidar transmitter, optimization of the receiver using optical ray tracing software, evaluation of detectors and amplifiers in the near RI, test of OPO and receiver technology, development of hardware and software for laser and scanner control and video display of the scan region.

  13. Scanning laser polarimetry in eyes with exfoliation syndrome.

    Science.gov (United States)

    Dimopoulos, Antonios T; Katsanos, Andreas; Mikropoulos, Dimitrios G; Giannopoulos, Theodoros; Empeslidis, Theodoros; Teus, Miguel A; Holló, Gábor; Konstas, Anastasios G P

    2013-01-01

    To compare retinal nerve fiber layer thickness (RNFLT) of normotensive eyes with exfoliation syndrome (XFS) and healthy eyes.
 Sixty-four consecutive individuals with XFS and normal office-time intraocular pressure (IOP) and 72 consecutive healthy controls were prospectively enrolled for a cross-sectional analysis in this hospital-based observational study. The GDx-VCC parameters (temporal-superior-nasal-inferior-temporal [TSNIT] average, superior average, inferior average, TSNIT standard deviation (SD), and nerve fiber indicator [NFI]) were compared between groups. Correlation between various clinical parameters and RNFLT parameters was investigated with Spearman coefficient. 
 The NFI, although within normal limits for both groups, was significantly greater in the XFS group compared to controls: the respective median and interquartile range (IQR) values were 25.1 (22.0-29.0) vs 15.0 (12.0-20.0), ppolarimetry-determined RNFLT was lower in XFS eyes with normal IOP. Therefore, close monitoring of RNFLT may facilitate early identification of those XFS eyes that convert to exfoliative glaucoma.

  14. Eye Absence Does Not Regulate Planarian Stem Cells during Eye Regeneration.

    Science.gov (United States)

    LoCascio, Samuel A; Lapan, Sylvain W; Reddien, Peter W

    2017-02-27

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, facilitating regeneration. Eye removal alone, however, did not induce this response. Eye regeneration following eye-specific resection resulted from homeostatic rates of eye progenitor production and less cell death in the regenerating eye. Conversely, large head injuries that left eyes intact increased eye progenitor production. Large injuries also non-specifically increased progenitor production for multiple uninjured tissues. We propose a model for eye regeneration in which eye tissue production by planarian stem cells is not directly regulated by the absence of the eye itself. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Evaluation of lateral margin of left lobe of the liver on CT scan : focus on perisplenic extension

    International Nuclear Information System (INIS)

    Seo, Chang Hye; Cha, Seong Sook; Lee, Byung Jin; Choi, Jae Young; Choi, Seok Jin; Eun, Choong Ki

    1996-01-01

    The perisplenic extension of the left lobe of the liver can be misinterpreted as a splenic or perisplenic lesion on ultrasonography(US) and computed tomography(CT). The purpose of our study is to classify the lateral margin of the left lobe of the liver into three types and to evaluate the incidence and the relationship between each type and abnormal liver on CT scan. A total of 515 abdominal CT scans from patients over 15 years old were retrospectively evaluated. Liver contours were divided into three types on the basis of degree of the left lateral extension of the left lobe of the liver. Type A was defined as the lateral extension of the left lobe of liver to the medial portion of the stomach, type C as the perisplenic portion, and type B as between the two types. Each type was further divided into normal and abnormal liver groups based on clinical, CT, surgical and patholigic findings and evaluated on its ratio of normal and abnormal liver, intrahepatic diseases associated with an abnormal liver and statistical significance between a normal and abnormal liver. The incidence of the three types of liver among the 515 patients was 360(69.9%), 121(23.5%) and 34(6.6%) patients in type A, B and C, respectively. Type C showed normal liver in six patients, which was 2.7% of all normal livers(221/515) and abnormal liver in 28 patients, which was 9.5% of all abnormal livers(294/515). Type A showed normal liver in 49.7%, abnormal liver in 50.3% and there was not statistically significant difference between normal and abnormal liver(p>0.05). Type B showed normal liver in 29.8% and abnormal liver in 70.2%;type C showed normal liver in 17.6%, abnormal liver in 82.4% and there was a statistically significant difference between normal and abnormal liver(P<0.001). The space occupying lesion(SOL) was most common(52.6%) in all the abnormal livers and hepatoma was the most common disease in the SOL(47.2%). In the abnormal type C liver, SOL(58%) and diffuse hepatopathy(32.8%) were

  16. Simulation of eye-tracker latency, spot size, and ablation pulse depth on the correction of higher order wavefront aberrations with scanning spot laser systems.

    Science.gov (United States)

    Bueeler, Michael; Mrochen, Michael

    2005-01-01

    The aim of this theoretical work was to investigate the robustness of scanning spot laser treatments with different laser spot diameters and peak ablation depths in case of incomplete compensation of eye movements due to eye-tracker latency. Scanning spot corrections of 3rd to 5th Zernike order wavefront errors were numerically simulated. Measured eye-movement data were used to calculate the positioning error of each laser shot assuming eye-tracker latencies of 0, 5, 30, and 100 ms, and for the case of no eye tracking. The single spot ablation depth ranged from 0.25 to 1.0 microm and the spot diameter from 250 to 1000 microm. The quality of the ablation was rated by the postoperative surface variance and the Strehl intensity ratio, which was calculated after a low-pass filter was applied to simulate epithelial surface smoothing. Treatments performed with nearly ideal eye tracking (latency approximately 0) provide the best results with a small laser spot (0.25 mm) and a small ablation depth (250 microm). However, combinations of a large spot diameter (1000 microm) and a small ablation depth per pulse (0.25 microm) yield the better results for latencies above a certain threshold to be determined specifically. Treatments performed with tracker latencies in the order of 100 ms yield similar results as treatments done completely without eye-movement compensation. CONCWSIONS: Reduction of spot diameter was shown to make the correction more susceptible to eye movement induced error. A smaller spot size is only beneficial when eye movement is neutralized with a tracking system with a latency <5 ms.

  17. Comparison of corneal measurements in keratoconic eyes using rotating Scheimpflug camera and scanning-slit topography

    Directory of Open Access Journals (Sweden)

    Mohammad Naderan

    2015-04-01

    Full Text Available AIM: To compare the anterior segment measurements obtained by rotating Scheimpflug camera (Pentacam and Scanning-slit topography (Orbscan IIz in keratoconic eyes. METHODS: A total of 121 patients, 71 males (58.7% and 50 females (41.3% (214 eyes with the diagnosis of keratoconus (KC were enrolled in this study. Following diagnosis of KC by slit-lamp biomicroscopic examination, central corneal thickness (CCT, thinnest corneal thickness (TCT, anterior chamber depth (ACD, and pupil diameter (PD were measured by a single examiner using successive instrumentation by Pentacam and Orbscan. RESULTS: There was no significant difference between the two instruments for the measurement of CCT and TCT. In contrast, scanning-slit topography measured ACD (3.46±0.40 mm vs. 3.38±0.33 mm, P=0.019 and PD (4.97±1.26 mm vs 4.08±1.19 mm, P<0.001 significantly larger than rotating Scheimpflug camera. The two devices made similar measurements for CCT (95% CI: -2.94 to 5.06, P=0.602. However, the mean difference for TCT was -6.28 (95% CI: -10.51 to -2.06, P=0.004 showing a thinner measurement by Orbscan than by Pentacam. In terms of the ACD, the mean difference was 0.08 mm (95% CI: 0.04 to 0.12, P<0.001 with Orbscan giving a slightly larger value than Pentacam. Similarly, Orbscan measurement for PD was longer than Pentacam (95% CI: 0.68 to 1.08, P<0.001. CONCLUSION: A good agreement was found between Pentacam and Orbscan concerning CCT measurement while comparing scanning-slit topography and rotating Scheimpflug camera there was an underestimation for TCT and overestimation for ACD and PD.

  18. "Looking-at-nothing" during sequential sensorimotor actions: Long-term memory-based eye scanning of remembered target locations.

    Science.gov (United States)

    Foerster, Rebecca M

    2018-03-01

    Before acting humans saccade to a target object to extract relevant visual information. Even when acting on remembered objects, locations previously occupied by relevant objects are fixated during imagery and memory tasks - a phenomenon called "looking-at-nothing". While looking-at-nothing was robustly found in tasks encouraging declarative memory built-up, results are mixed in the case of procedural sensorimotor tasks. Eye-guidance to manual targets in complete darkness was observed in a task practiced for days beforehand, while investigations using only a single session did not find fixations to remembered action targets. Here, it is asked whether looking-at-nothing can be found in a single sensorimotor session and thus independent from sleep consolidation, and how it progresses when visual information is repeatedly unavailable. Eye movements were investigated in a computerized version of the trail making test. Participants clicked on numbered circles in ascending sequence. Fifty trials were performed with the same spatial arrangement of 9 visual targets to enable long-term memory consolidation. During 50 consecutive trials, participants had to click the remembered target sequence on an empty screen. Participants scanned the visual targets and also the empty target locations sequentially with their eyes, however, the latter less precise than the former. Over the course of the memory trials, manual and oculomotor sequential target scanning became more similar to the visual trials. Results argue for robust looking-at-nothing during procedural sensorimotor tasks provided that long-term memory information is sufficient. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Through your eyes or mine? The neural correlates of mental state recognition in Huntington's disease.

    Science.gov (United States)

    Eddy, Clare M; Rickards, Hugh E; Hansen, Peter C

    2018-03-01

    Huntington's disease (HD) can impair social cognition. This study investigated whether patients with HD exhibit neural differences to healthy controls when they are considering mental and physical states relating to the static expressions of human eyes. Thirty-two patients with HD and 28 age-matched controls were scanned with fMRI during two versions of the Reading the Mind in the Eyes Task: The standard version requiring mental state judgments, and a comparison version requiring judgments about age. HD was associated with behavioral deficits on only the mental state eyes task. Contrasting the two versions of the eyes task (mental state > age judgment) revealed hypoactivation within left middle frontal gyrus and supramarginal gyrus in HD. Subgroup analyses comparing premanifest HD patients to age-matched controls revealed reduced activity in right supramarginal gyrus and increased activity in anterior cingulate during mental state recognition in these patients, while manifest HD was associated with hypoactivity in left insula and left supramarginal gyrus. When controlling for the effects of healthy aging, manifest patients exhibited declining activation within areas including right temporal pole. Our findings provide compelling evidence for a selective impairment of internal emotional status when patients with HD appraise facial features in order to make social judgements. Differential activity in temporal and anterior cingulate cortices may suggest that poor emotion regulation and emotional egocentricity underlie impaired mental state recognition in premanifest patients, while more extensive mental state recognition impairments in manifest disease reflect dysfunction in neural substrates underlying executive functions, and the experience and interpretation of emotion. © 2017 Wiley Periodicals, Inc.

  20. Eye micromotions influence on an error of Zernike coefficients reconstruction in the one-ray refractometry of an eye

    Science.gov (United States)

    Osipova, Irina Y.; Chyzh, Igor H.

    2001-06-01

    The influence of eye jumps on the accuracy of estimation of Zernike coefficients from eye transverse aberration measurements was investigated. By computer modeling the ametropy and astigmatism have been examined. The standard deviation of the wave aberration function was calculated. It was determined that the standard deviation of the wave aberration function achieves the minimum value if the number of scanning points is equal to the number of eye jumps in scanning period. The recommendations for duration of measurement were worked out.

  1. Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.

    Science.gov (United States)

    Wong, Hon-Tym; Chua, Jocelyn L L; Sakata, Lisandro M; Wong, Melissa H Y; Aung, Han T; Aung, Tin

    2009-05-01

    To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.

  2. Neurally Derived Tissues in Xenopus laevis Embryos Exhibit a Consistent Bioelectrical Left-Right Asymmetry

    Directory of Open Access Journals (Sweden)

    Vaibhav P. Pai

    2012-01-01

    Full Text Available Consistent left-right asymmetry in organ morphogenesis is a fascinating aspect of bilaterian development. Although embryonic patterning of asymmetric viscera, heart, and brain is beginning to be understood, less is known about possible subtle asymmetries present in anatomically identical paired structures. We investigated two important developmental events: physiological controls of eye development and specification of neural crest derivatives, in Xenopus laevis embryos. We found that the striking hyperpolarization of transmembrane potential (Vmem demarcating eye induction usually occurs in the right eye field first. This asymmetry is randomized by perturbing visceral left-right patterning, suggesting that eye asymmetry is linked to mechanisms establishing primary laterality. Bilateral misexpression of a depolarizing channel mRNA affects primarily the right eye, revealing an additional functional asymmetry in the control of eye patterning by Vmem. The ATP-sensitive K+ channel subunit transcript, SUR1, is asymmetrically expressed in the eye primordia, thus being a good candidate for the observed physiological asymmetries. Such subtle asymmetries are not only seen in the eye: consistent asymmetry was also observed in the migration of differentiated melanocytes on the left and right sides. These data suggest that even anatomically symmetrical structures may possess subtle but consistent laterality and interact with other developmental left-right patterning pathways.

  3. Greater Activity in the Frontal Cortex on Left Curves: A Vector-Based fNIRS Study of Left and Right Curve Driving.

    Directory of Open Access Journals (Sweden)

    Noriyuki Oka

    Full Text Available In the brain, the mechanisms of attention to the left and the right are known to be different. It is possible that brain activity when driving also differs with different horizontal road alignments (left or right curves, but little is known about this. We found driver brain activity to be different when driving on left and right curves, in an experiment using a large-scale driving simulator and functional near-infrared spectroscopy (fNIRS.The participants were fifteen healthy adults. We created a course simulating an expressway, comprising straight line driving and gentle left and right curves, and monitored the participants under driving conditions, in which they drove at a constant speed of 100 km/h, and under non-driving conditions, in which they simply watched the screen (visual task. Changes in hemoglobin concentrations were monitored at 48 channels including the prefrontal cortex, the premotor cortex, the primary motor cortex and the parietal cortex. From orthogonal vectors of changes in deoxyhemoglobin and changes in oxyhemoglobin, we calculated changes in cerebral oxygen exchange, reflecting neural activity, and statistically compared the resulting values from the right and left curve sections.Under driving conditions, there were no sites where cerebral oxygen exchange increased significantly more during right curves than during left curves (p > 0.05, but cerebral oxygen exchange increased significantly more during left curves (p < 0.05 in the right premotor cortex, the right frontal eye field and the bilateral prefrontal cortex. Under non-driving conditions, increases were significantly greater during left curves (p < 0.05 only in the right frontal eye field.Left curve driving was thus found to require more brain activity at multiple sites, suggesting that left curve driving may require more visual attention than right curve driving. The right frontal eye field was activated under both driving and non-driving conditions.

  4. Greater Activity in the Frontal Cortex on Left Curves: A Vector-Based fNIRS Study of Left and Right Curve Driving

    Science.gov (United States)

    Oka, Noriyuki; Yoshino, Kayoko; Yamamoto, Kouji; Takahashi, Hideki; Li, Shuguang; Sugimachi, Toshiyuki; Nakano, Kimihiko; Suda, Yoshihiro; Kato, Toshinori

    2015-01-01

    Objectives In the brain, the mechanisms of attention to the left and the right are known to be different. It is possible that brain activity when driving also differs with different horizontal road alignments (left or right curves), but little is known about this. We found driver brain activity to be different when driving on left and right curves, in an experiment using a large-scale driving simulator and functional near-infrared spectroscopy (fNIRS). Research Design and Methods The participants were fifteen healthy adults. We created a course simulating an expressway, comprising straight line driving and gentle left and right curves, and monitored the participants under driving conditions, in which they drove at a constant speed of 100 km/h, and under non-driving conditions, in which they simply watched the screen (visual task). Changes in hemoglobin concentrations were monitored at 48 channels including the prefrontal cortex, the premotor cortex, the primary motor cortex and the parietal cortex. From orthogonal vectors of changes in deoxyhemoglobin and changes in oxyhemoglobin, we calculated changes in cerebral oxygen exchange, reflecting neural activity, and statistically compared the resulting values from the right and left curve sections. Results Under driving conditions, there were no sites where cerebral oxygen exchange increased significantly more during right curves than during left curves (p > 0.05), but cerebral oxygen exchange increased significantly more during left curves (p right premotor cortex, the right frontal eye field and the bilateral prefrontal cortex. Under non-driving conditions, increases were significantly greater during left curves (p right frontal eye field. Conclusions Left curve driving was thus found to require more brain activity at multiple sites, suggesting that left curve driving may require more visual attention than right curve driving. The right frontal eye field was activated under both driving and non-driving conditions

  5. Binocular Fusion and Invariant Category Learning due to Predictive Remapping during Scanning of a Depthful Scene with Eye Movements

    Directory of Open Access Journals (Sweden)

    Stephen eGrossberg

    2015-01-01

    Full Text Available How does the brain maintain stable fusion of 3D scenes when the eyes move? Every eye movement causes each retinal position to process a different set of scenic features, and thus the brain needs to binocularly fuse new combinations of features at each position after an eye movement. Despite these breaks in retinotopic fusion due to each movement, previously fused representations of a scene in depth often appear stable. The 3D ARTSCAN neural model proposes how the brain does this by unifying concepts about how multiple cortical areas in the What and Where cortical streams interact to coordinate processes of 3D boundary and surface perception, spatial attention, invariant object category learning, predictive remapping, eye movement control, and learned coordinate transformations. The model explains data from single neuron and psychophysical studies of covert visual attention shifts prior to eye movements. The model further clarifies how perceptual, attentional, and cognitive interactions among multiple brain regions (LGN, V1, V2, V3A, V4, MT, MST, PPC, LIP, ITp, ITa, SC may accomplish predictive remapping as part of the process whereby view-invariant object categories are learned. These results build upon earlier neural models of 3D vision and figure-ground separation and the learning of invariant object categories as the eyes freely scan a scene. A key process concerns how an object’s surface representation generates a form-fitting distribution of spatial attention, or attentional shroud, in parietal cortex that helps maintain the stability of multiple perceptual and cognitive processes. Predictive eye movement signals maintain the stability of the shroud, as well as of binocularly fused perceptual boundaries and surface representations.

  6. Binocular fusion and invariant category learning due to predictive remapping during scanning of a depthful scene with eye movements

    Science.gov (United States)

    Grossberg, Stephen; Srinivasan, Karthik; Yazdanbakhsh, Arash

    2015-01-01

    How does the brain maintain stable fusion of 3D scenes when the eyes move? Every eye movement causes each retinal position to process a different set of scenic features, and thus the brain needs to binocularly fuse new combinations of features at each position after an eye movement. Despite these breaks in retinotopic fusion due to each movement, previously fused representations of a scene in depth often appear stable. The 3D ARTSCAN neural model proposes how the brain does this by unifying concepts about how multiple cortical areas in the What and Where cortical streams interact to coordinate processes of 3D boundary and surface perception, spatial attention, invariant object category learning, predictive remapping, eye movement control, and learned coordinate transformations. The model explains data from single neuron and psychophysical studies of covert visual attention shifts prior to eye movements. The model further clarifies how perceptual, attentional, and cognitive interactions among multiple brain regions (LGN, V1, V2, V3A, V4, MT, MST, PPC, LIP, ITp, ITa, SC) may accomplish predictive remapping as part of the process whereby view-invariant object categories are learned. These results build upon earlier neural models of 3D vision and figure-ground separation and the learning of invariant object categories as the eyes freely scan a scene. A key process concerns how an object's surface representation generates a form-fitting distribution of spatial attention, or attentional shroud, in parietal cortex that helps maintain the stability of multiple perceptual and cognitive processes. Predictive eye movement signals maintain the stability of the shroud, as well as of binocularly fused perceptual boundaries and surface representations. PMID:25642198

  7. Binocular fusion and invariant category learning due to predictive remapping during scanning of a depthful scene with eye movements.

    Science.gov (United States)

    Grossberg, Stephen; Srinivasan, Karthik; Yazdanbakhsh, Arash

    2014-01-01

    How does the brain maintain stable fusion of 3D scenes when the eyes move? Every eye movement causes each retinal position to process a different set of scenic features, and thus the brain needs to binocularly fuse new combinations of features at each position after an eye movement. Despite these breaks in retinotopic fusion due to each movement, previously fused representations of a scene in depth often appear stable. The 3D ARTSCAN neural model proposes how the brain does this by unifying concepts about how multiple cortical areas in the What and Where cortical streams interact to coordinate processes of 3D boundary and surface perception, spatial attention, invariant object category learning, predictive remapping, eye movement control, and learned coordinate transformations. The model explains data from single neuron and psychophysical studies of covert visual attention shifts prior to eye movements. The model further clarifies how perceptual, attentional, and cognitive interactions among multiple brain regions (LGN, V1, V2, V3A, V4, MT, MST, PPC, LIP, ITp, ITa, SC) may accomplish predictive remapping as part of the process whereby view-invariant object categories are learned. These results build upon earlier neural models of 3D vision and figure-ground separation and the learning of invariant object categories as the eyes freely scan a scene. A key process concerns how an object's surface representation generates a form-fitting distribution of spatial attention, or attentional shroud, in parietal cortex that helps maintain the stability of multiple perceptual and cognitive processes. Predictive eye movement signals maintain the stability of the shroud, as well as of binocularly fused perceptual boundaries and surface representations.

  8. Basal cell carcinoma on the left cheek

    International Nuclear Information System (INIS)

    Jancar, B.

    2007-01-01

    A 91-year-old female patient was treated with irradiation for histologically confirmed basal cell carcinoma on the left cheek. The tumour, measuring 3 x 3 cm, with the depth of 2 cm, was extending up to the lower lid of the left eye. (author)

  9. Left ventricular filling rate change as an earlier indicator than ejection fraction of chemotherapeutic cardiotoxicity in cancer paptents' nuclear medicine MUGA scans

    International Nuclear Information System (INIS)

    Miko, T.G.

    2004-01-01

    According to Wang Siegel has long suggested that an earlier indicator of damage to the hearts of cancer patients undergoing potentially cardiotoxic chemotherapy could be change in the left ventricular filling rate (LVFT) rather than dependence on the left ventricular ejection fraction (LVEF) as a measure for when to discontinue chemotherapy. Currently ejection fraction obtained by performing the nuclear medicine MUGA scan is the gold standard for determining further treatment of patients with these cardiotoxic agents. We are seeking to see if changes in filling rate (LVFR) are an earlier indicator of cardiotoxicity by performing a retrospective analysis of MUGA scans performed at our facility pre- and post-chemotherapy and performing a statistical analysis of changes in ejection fraction us filling rate in patients known to have cardiotoxic changes due to chemotherapy. (authors)

  10. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): a transversal, descriptive, and comparative study.

    Science.gov (United States)

    Velez-Montoya, Raul; Shusterman, Eugene Mark; López-Miranda, Miriam Jessica; Mayorquin-Ruiz, Mariana; Salcedo-Villanueva, Guillermo; Quiroz-Mercado, Hugo; Morales-Cantón, Virgilio

    2010-03-24

    To assess the reliability of the measurements obtained with the PalmScan, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan A2000 and Eye Cubed) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed of AL and ACD were shorter than the measurements taken by the PalmScan. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan measurements were shorter, but not statistically significantly (p < 0.2). The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon.

  11. Analysis of EEG Related Saccadic Eye Movement

    Science.gov (United States)

    Funase, Arao; Kuno, Yoshiaki; Okuma, Shigeru; Yagi, Tohru

    Our final goal is to establish the model for saccadic eye movement that connects the saccade and the electroencephalogram(EEG). As the first step toward this goal, we recorded and analyzed the saccade-related EEG. In the study recorded in this paper, we tried detecting a certain EEG that is peculiar to the eye movement. In these experiments, each subject was instructed to point their eyes toward visual targets (LEDs) or the direction of the sound sources (buzzers). In the control cases, the EEG was recorded in the case of no eye movemens. As results, in the visual experiments, we found that the potential of EEG changed sharply on the occipital lobe just before eye movement. Furthermore, in the case of the auditory experiments, similar results were observed. In the case of the visual experiments and auditory experiments without eye movement, we could not observed the EEG changed sharply. Moreover, when the subject moved his/her eyes toward a right-side target, a change in EEG potential was found on the right occipital lobe. On the contrary, when the subject moved his/her eyes toward a left-side target, a sharp change in EEG potential was found on the left occipital lobe.

  12. Task demands modulate decision and eye movement responses in the chimeric face test: examining the right hemisphere processing account

    Directory of Open Access Journals (Sweden)

    Jason eCoronel

    2014-03-01

    Full Text Available A large and growing body of work, conducted in both brain-intact and brain-damaged populations, has used the free viewing chimeric face test as a measure of hemispheric dominance for the extraction of emotional information from faces. These studies generally show that normal right-handed individuals tend to perceive chimeric faces as more emotional if the emotional expression is presented on the half of the face to the viewer’s left (left hemiface. However, the mechanisms underlying this lateralized bias remain unclear. Here, we examine the extent to which this bias is driven by right hemisphere processing advantages versus default scanning biases in a unique way -- by changing task demands. In particular, we compare the original task with one in which right-hemisphere-biased processing cannot provide a decision advantage. Our behavioral and eye-movement data are inconsistent with the predictions of a default scanning bias account and support the idea that the left hemiface bias found in the chimeric face test is largely due to strategic use of right hemisphere processing mechanisms.

  13. Impact of Anodal and Cathodal Transcranial Direct Current Stimulation over the Left Dorsolateral Prefrontal Cortex during Attention Bias Modification: An Eye-Tracking Study.

    Directory of Open Access Journals (Sweden)

    Alexandre Heeren

    Full Text Available People with anxiety disorders show an attentional bias for threat (AB, and Attention Bias Modification (ABM procedures have been found to reduce this bias. However, the underlying processes accounting for this effect remain poorly understood. One explanation suggests that ABM requires the modification of attention control, driven by the recruitment of the dorsolateral prefrontal cortex (DLPFC. In the present double-blind study, we examined whether modifying left DLPFC activation influences the effect of ABM on AB. We used transcranial direct current stimulation (tDCS to directly modulate cortical excitability of the left DLPFC during an ABM procedure designed to reduce AB to threat. Anodal tDCS increases excitability, whereas cathodal tDCS decreases it. We randomly assigned highly trait-anxious individuals to one of three conditions: 1 ABM combined with cathodal tDCS, 2 ABM combined with anodal tDCS, or 3 ABM combined with sham tDCS. We assessed the effects of these manipulations on both reaction times and eye-movements on a task indexing AB. Results indicate that combining ABM and anodal tDCS over the left DLPFC reduces the total duration that participants' gaze remains fixated on threat, as assessed using eye-tracking measurement. However, in contrast to previous studies, there were no changes in AB from baseline to post-training for participants that received ABM without tDCS. As the tendency to maintain attention to threat is known to play an important role in the maintenance of anxiety, the present findings suggest that anodal tDCS over the left DLPFC may be considered as a promising tool to reduce the maintenance of gaze to threat. Implications for future translational research combining ABM and tDCS are discussed.

  14. Eye laterality: a comprehensive analysis in refractive surgery candidates.

    Science.gov (United States)

    Linke, Stephan J; Druchkiv, Vasyl; Steinberg, Johannes; Richard, Gisbert; Katz, Toam

    2013-08-01

    To explore eye laterality (higher refractive error in one eye) and its association with refractive state, spherical/astigmatic anisometropia, age and sex in refractive surgery candidates. Medical records of 12 493 consecutive refractive surgery candidates were filtered. Refractive error (subjective and cycloplegic) was measured in each subject and correlated with eye laterality. Only subjects with corrected distance visual acuity (CDVA) of >20/22 in each eye were enrolled to exclude amblyopia. Associations between eye laterality and refractive state were analysed by means of t-test, chi-squared test, Spearman's correlation and multivariate logistic regression analysis, respectively. There was no statistically significant difference in spherical equivalent between right (-3.47 ± 2.76 D) and left eyes (-3.47 ± 2.76 D, p = 0.510; Pearson's r = 0.948, p laterality for anisometropia >2.5 D in myopic (-5.64 ± 2.5 D versus -4.92 ± 2.6 D; p = 0.001) and in hyperopic (4.44 ± 1.69 D versus 3.04 ± 1.79 D; p = 0.025) subjects, (II) a tendency for left eye cylindrical laterality in myopic subjects, and (III) myopic male subjects had a higher prevalence of left eye laterality. (IV) Age did not show any significant impact on laterality. Over the full refractive spectrum, this study confirmed previously described strong interocular refractive correlation but revealed a statistically significant higher rate of right eye laterality for anisometropia >2.5 D. In general, our results support the use of data from one eye only in studies of ocular refraction. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.

  15. Industrial site particulate pollution monitoring with an eye-safe and scanning industrial fiber lidar

    Science.gov (United States)

    Belanger, Brigitte; Fougeres, Andre; Talbot, Mario

    2001-02-01

    12 Over the past few years, INO has developed an Industrial Fiber Lidar (IFL). It enables the particulate pollution monitoring on industrial sites. More particularly, it has been used to take measurements of particulate concentration at Port Facilities of an aluminum plant during boat unloading. It is an eye-safe and portable lidar. It uses a fiber laser also developed at INO emitting 1.7 microJoules at 1534 nm with a pulse repetition frequency of 5 kHz. Given the harsh environment of an industrial site, all the sensitive equipment like the laser source, detector, computer and acquisition electronics are located in a building and connected to the optical module, placed outside, via optical fibers up to 500 m long. The fiber link also offers all the flexibility for placing the optical module at a proper location. The optical module is mounted on a two axis scanning platform, able to perform an azimuth scan of 0 to 355 deg and an elevation scan of +/- 90 deg, which enables the scanning of zones defined by the user. On this industrial site, materials like bauxite, alumina, spathfluor and calcined coke having mass extinction coefficients ranging from 0.53 to 2.7 m2/g can be detected. Data for different measurement configurations have been obtained. Concentration values have been calculated for measurements in a hopper, along a wharf and over the urban area close to the port facilities. The lidar measurements have been compared to high volume samplers. Based on these comparisons, it has been established that the IFL is able to monitor the relative fluctuations of dust concentrations. It can be integrated to the process control of the industrial site for alarm generation when concentrations are above threshold.

  16. Iris coloboma in one eye and pigment dispersion syndrome in the fellow eye.

    Science.gov (United States)

    Galvis, Virgilio; Tello, Alejandro; Valarezo, Paul; Prada, Angélica M

    2013-05-22

    We report a case of a 43-year-old patient with coloboma of the iris, zonule, ciliary body, choroid and retina in the right eye and pigment dispersion syndrome in the left eye. Considering the hypothesis of the pigment dispersion syndrome pathogenesis in which a difference of pressures in the anterior and posterior chambers creates a posterior convexity of the iris leading to reverse pupillary block, iris touch and consequently causing pigment dispersion, we suggest that the presence of an iris coloboma, by equalising the pressures in the two chambers, prevented the onset of syndrome in that eye.

  17. Case control study of dry eye and related ocular surface abnormalities in Ibadan, Nigeria.

    Science.gov (United States)

    Bekibele, C O; Baiyeroju, A M; Ajaiyeoba, A; Akang, E E U; Ajayi, B G K

    2010-02-01

    Tear instability is associated with symptoms of ocular discomfort and irritation. Many patients with dry eyes remain untreated due to improper diagnoses. To identify symptoms and surface abnormalities associated with dry eyes. One hundred and fifty-six eyes of 78 subjects attending the Eye Clinic of the University College Hospital Ibadan were screened for dry eyes/tear instability using rose Bengal stain (graded 0-9), tear break-up time (TBUT), Schirmer's 1 tests, tear meniscus height and a standardised symptoms questionnaire. Grades 4-9 rose Bengal staining were considered as positive dry eye and were compared with grades 0-3 staining eyes as negative controls. Mean tear meniscus height, Schirmer's test and TBUT were lower among cases than their corresponding control eyes. The difference between the mean Schirmer's test values of cases and their controls were statistically significant (P = 0.00 for right eyes and P = 0.002 for left eyes). Rose Bengal grades were inversely correlated with the mean Schirmer's values (Pearson correlation -0.429, P = 0.05 for right eyes and -0.335, P = 0.03 for left eyes) and TBUT (Pearson correlation -0.316, P = 0.05 for right eyes and -0.212, P = 0.06 for left eyes). About 95.8% of the cases were symptomatic, as opposed to 70.4% of the controls (P = 0.01, Fisher's exact test) and 95.8% of dry right eyes compared to 61.1% of their controls had ocular surface abnormalities (P = 0.001), while 89.5% of dry left eyes compared to 62.7% of controls had surface abnormalities (P = 0.07). A close relationship exists between ocular irritation symptoms, surface abnormalities and functional evidence of tear instability. Such patients should be treated empirically or screened for dry eyes.

  18. Owl's eye appearance: a case report

    International Nuclear Information System (INIS)

    Mathur, Mukul; Asha, P.

    2010-01-01

    Full text: Hyper-functioning thyroid nodule may present various scintigraphic appearances on thyroid scans. Autonomously hyper functioning thyroid nodules often show degenerative changes. These changes may give rise to peripheral photopenic areas on a thyroid scan. In this report we present a case of hyper functioning nodule showing appearance of an owl's eye. Although rare, such pattern can be seen in a variety of benign and malignant thyroid conditions. A 42-year-old man presented with a solitary thyroid nodule in the right lobe and weight loss for four months. The thyroid hormone profile confirmed hyperthyroidism. Thyroid function testing revealed T4=136.8 nmol/l (Normal = 66.0-181.0 nmol/L) and Thyroid Stimulating Hormone (TSH) = 0.283 (Normal =0.27- 4.2 μIU/ml). Antithyroglobulin antibodies and antimicrosmal antibodies were negative. The patient was referred for thyroid scan and uptake. A Thyroid scan was obtained after the intravenous injection of 5 mCi (185MBq) of 99m Tc pertechnetate. Anterior view obtained using a parallel hole collimator. The scan showed peripheral photopenic area with a central focal area of increased uptake giving the appearance of 'Owl's eye'. 99m Tc-pertechnetate uptake was increased. A scintigraphic 'Owl's eye' sign has been described in thyroid cyst, benign autonomous nodule and papillary carcinoma of the thyroid gland. This Owl's eye pattern appears to be caused by a focus of functioning tissue overlapping a large cold area in a nodule that has cystic,degenerative and necrotic changes in the middle of a benign and malignant pathology. Hyper functioning nodules may scintigraphically show Owl's eye pattern due to intra nodular degeneration, with residual hyper functioning tissue within or overlapping the degenerative area

  19. "It is the left eye, right?"

    Directory of Open Access Journals (Sweden)

    Pikkel D

    2014-04-01

    Full Text Available Dvora Pikkel,1 Adi Sharabi-Nov,2,3 Joseph Pikkel4,5 1Risk Management and Patient Safety Unit, Assuta Hospital, Ramat Hachayal, Tel-Aviv, Israel; 2Research Wing, Ziv Medical Center, Safed, Israel; 3Tel-Hai Academic College, Upper Galilee, Israel; 4Department of Ophthalmology, Ziv Medical Center, Safed, Israel; 5Faculty of Medicine, Bar-Ilan University, Ramat Gan, Tel Aviv, Israel Objective: Because wrong-site confusion is among the most common mistakes in the operations of paired organs, we have examined the frequency of wrong-sided confusions that could theoretically occur in cataract surgeries in the absence of preoperative verification. Methods: Ten cataract surgeons participated in the study. The surgeons were asked to complete a questionnaire that included their demographic data, occupational habits, and their approach to and the handling of patients preoperatively. On the day of operation, the surgeons were asked to recognize the side of the operation from the patient's name only. At the second stage of the study, surgeons were asked to recognize the side of the operation while standing a 2-meter distance from the patient's face. The surgeons' answers were compared to the actual operation side. Patients then underwent a full time-out procedure, which included side marking before the operation. Results: Of the total 67 patients, the surgeons correctly identified the operated side of the eye in 49 (73% by name and in 56 (83% by looking at patients' faces. Wrong-side identification correlated with the time lapsed from the last preoperative examination (P=0.034. The number of cataract surgeries performed by the same surgeon (on the same day also correlated to the number of wrong identifications (P=0.000. Surgeon seniority or age did not correlate to the number of wrong identifications. Conclusion: This study illustrates the high error rate that can result in the absence of side marking prior to cataract surgery, as well as in operations on

  20. Quantum dots trace lymphatic drainage from the mouse eye

    Energy Technology Data Exchange (ETDEWEB)

    Tam, Alex L C; Gupta, Neeru; Zhang Zhexue; Yuecel, Yeni H, E-mail: yucely@smh.ca [Department of Ophthalmology and Vision Sciences, University of Toronto, M5T 2S8 (Canada)

    2011-10-21

    Glaucoma is a leading cause of blindness in the world, often associated with elevated eye pressure. Currently, all glaucoma treatments aim to lower eye pressure by improving fluid exit from the eye. We recently reported the presence of lymphatics in the human eye. The lymphatic circulation is known to drain fluid from organ tissues and, as such, lymphatics may also play a role in draining fluid from the eye. We investigated whether lymphatic drainage from the eye is present in mice by visualizing the trajectory of quantum dots once injected into the eye. Whole-body hyperspectral fluorescence imaging was performed in 17 live mice. In vivo imaging was conducted prior to injection, and 5, 20, 40 and 70 min, and 2, 6 and 24 h after injection. A quantum dot signal was observed in the left neck region at 6 h after tracer injection into the eye. Examination of immunofluorescence-labelled sections using confocal microscopy showed the presence of a quantum dot signal in the left submandibular lymph node. This is the first direct evidence of lymphatic drainage from the mouse eye. The use of quantum dots to image this lymphatic pathway in vivo is a novel tool to stimulate new treatments to reduce eye pressure and prevent blindness from glaucoma.

  1. Quantum dots trace lymphatic drainage from the mouse eye

    International Nuclear Information System (INIS)

    Tam, Alex L C; Gupta, Neeru; Zhang Zhexue; Yuecel, Yeni H

    2011-01-01

    Glaucoma is a leading cause of blindness in the world, often associated with elevated eye pressure. Currently, all glaucoma treatments aim to lower eye pressure by improving fluid exit from the eye. We recently reported the presence of lymphatics in the human eye. The lymphatic circulation is known to drain fluid from organ tissues and, as such, lymphatics may also play a role in draining fluid from the eye. We investigated whether lymphatic drainage from the eye is present in mice by visualizing the trajectory of quantum dots once injected into the eye. Whole-body hyperspectral fluorescence imaging was performed in 17 live mice. In vivo imaging was conducted prior to injection, and 5, 20, 40 and 70 min, and 2, 6 and 24 h after injection. A quantum dot signal was observed in the left neck region at 6 h after tracer injection into the eye. Examination of immunofluorescence-labelled sections using confocal microscopy showed the presence of a quantum dot signal in the left submandibular lymph node. This is the first direct evidence of lymphatic drainage from the mouse eye. The use of quantum dots to image this lymphatic pathway in vivo is a novel tool to stimulate new treatments to reduce eye pressure and prevent blindness from glaucoma.

  2. Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2011-01-01

    Full Text Available We report a case of a bilateral posterior chamber implantable collamer lens (ICL implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.

  3. Laser safety in design of near-infrared scanning LIDARs

    Science.gov (United States)

    Zhu, X.; Elgin, D.

    2015-05-01

    3D LIDARs (Light Detection and Ranging) with 1.5μm nanosecond pulse lasers have been increasingly used in different applications. The main reason for their popularity is that these LIDARs have high performance while at the same time can be made eye-safe. Because the laser hazard effect on eyes or skin at this wavelength region (industrial mining applications. We have incorporated the laser safety requirements in the LIDAR design and conducted laser safety analysis for different operational scenarios. While 1.5μm is normally said to be the eye-safe wavelength, in reality a high performance 3D LIDAR needs high pulse energy, small beam size and high pulse repetition frequency (PRF) to achieve long range, high resolution and high density images. The resulting radiant exposure of its stationary beam could be many times higher than the limit for a Class 1 laser device. Without carefully choosing laser and scanning parameters, including field-of-view, scan speed and pattern, a scanning LIDAR can't be eye- or skin-safe based only on its wavelength. This paper discusses the laser safety considerations in the design of eye-safe scanning LIDARs, including laser pulse energy, PRF, beam size and scanning parameters in two basic designs of scanning mechanisms, i.e. galvanometer based scanner and Risley prism based scanner. The laser safety is discussed in terms of device classification, nominal ocular hazard distance (NOHD) and safety glasses optical density (OD).

  4. Lateralized eye use towards video stimuli in bearded dragons (Pogona vitticeps

    Directory of Open Access Journals (Sweden)

    Anna Frohnwieser

    2017-08-01

    Full Text Available Lateralized eye use is thought to increase brain efficiency, as the two hemispheres process different information perceived by the eyes. It has been observed in a wide variety of vertebrate species and, in general, information about conspecifics appears to elicit a left eye preference whilst information about prey elicits the opposite. In reptiles, this phenomenon has only been investigated using live conspecifics in agonistic contexts, and so it is not clear whether it can be found when using video stimuli. Here, bearded dragons (Pogona vitticeps were presented with videos of female conspecifics and prey that either moved or were stationary, along with a control video of an empty background. Females exhibited a left eye bias towards conspecifics but males did not; however, both sexes looked at conspecifics significantly longer than prey. Further, animals used their left eye significantly longer when viewing moving stimuli of both categories. These results suggest that, in lizards, lateralized eye use when viewing conspecifics may be controlled by sex, and strongly influenced by stimulus movement. This study, therefore, provides important insights into the role of lateralized processing in lizard perception, and sets the scene for future work investigating the role of sex on perception of conspecifics and the role of motion in lateralized eye use.

  5. High-resolution imaging of the retinal nerve fiber layer in normal eyes using adaptive optics scanning laser ophthalmoscopy.

    Science.gov (United States)

    Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Arakawa, Naoko; Oshima, Susumu; Shibata, Naohisa; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa

    2012-01-01

    To conduct high-resolution imaging of the retinal nerve fiber layer (RNFL) in normal eyes using adaptive optics scanning laser ophthalmoscopy (AO-SLO). AO-SLO images were obtained in 20 normal eyes at multiple locations in the posterior polar area and a circular path with a 3-4-mm diameter around the optic disc. For each eye, images focused on the RNFL were recorded and a montage of AO-SLO images was created. AO-SLO images for all eyes showed many hyperreflective bundles in the RNFL. Hyperreflective bundles above or below the fovea were seen in an arch from the temporal periphery on either side of a horizontal dividing line to the optic disc. The dark lines among the hyperreflective bundles were narrower around the optic disc compared with those in the temporal raphe. The hyperreflective bundles corresponded with the direction of the striations on SLO red-free images. The resolution and contrast of the bundles were much higher in AO-SLO images than in red-free fundus photography or SLO red-free images. The mean hyperreflective bundle width around the optic disc had a double-humped shape; the bundles at the temporal and nasal sides of the optic disc were narrower than those above and below the optic disc (Poptical coherence tomography correlated with the hyperreflective bundle widths on AO-SLO (Pfiber bundles and Müller cell septa. The widths of the nerve fiber bundles appear to be proportional to the RNFL thickness at equivalent distances from the optic disc.

  6. Multicolor pattern scan laser for diabetic retinopathy with cataract

    Institute of Scientific and Technical Information of China (English)

    Takao; Hirano; Yasuhiro; Iesato; Toshinori; Murata

    2014-01-01

    · AIM: To evaluate the ability of various laser wavelengths in delivering sufficient burns to the retina in eyes with cataract using a new multicolor pattern scan laser with green(532 nm), yellow(577 nm), and red(647 nm)lasers.·METHODS: The relationship between the Emery-Little(EL) degree of cataract severity and the laser wavelength required to deliver adequate burns was investigated in102 diabetic eyes. Treatment time, total number of laser shots, and intra-operative pain were assessed as well.·RESULTS: All EL-1 grade eyes and 50% of EL-2 eyes were successfully treated with the green laser, while 50%of EL-2 eyes, 96% of EL-3 eyes, and 50% of EL-4 eyes required the yellow laser. The red laser was effective in the remaining 4% of EL-3 and 50% of EL-4 eyes.·CONCLUSION: Longer wavelength lasers are more effective in delivering laser burns through cataract when we use a multicolor pattern scan laser system.

  7. Monitoring eye movements to investigate the picture superiority effect in spatial memory.

    Science.gov (United States)

    Cattaneo, Zaira; Rosen, Mitchell; Vecchi, Tomaso; Pelz, Jeff B

    2008-01-01

    Spatial memory is usually better for iconic than for verbal material. Our aim was to assess whether such effect is related to the way iconic and verbal targets are viewed when people have to memorize their locations. Eye movements were recorded while participants memorized the locations of images or words. Images received fewer, but longer, gazes than words. Longer gazes on images might reflect greater attention devoted to images due to their higher sensorial distinctiveness and/or generation with images of an additional phonological code beyond the visual code immediately available. We found that words were scanned mainly from left to right while a more heterogeneous scanning strategy characterized encoding of images. This suggests that iconic configurations tend to be maintained as global integrated representations in which all the item/location pairs are simultaneously present whilst verbal configurations are maintained through more sequential processes.

  8. Ultrasonographic biometry of the normal eye of the Persian cat.

    Science.gov (United States)

    Mirshahi, A; Shafigh, S H; Azizzadeh, M

    2014-07-01

    To describe the normal ultrasonographic biometry of the Persian cat's eyes using B-mode ultrasonography. In a cross-sectional study, 20 healthy Persian cats with no history of previous ophthalmic disease were examined. Ocular biometry of the left and right eyes was measured using B-mode ultrasonography. Comparison of the average measurements between left and right eyes and between vertical and horizontal planes was performed using paired-sample t test. Correlation of ocular parameters with sex, age, head circumference and eye colour was evaluated. Mean ± standard deviation (SD) measurements of the ocular structures of anterior chamber, lens thickness, vitreous chamber and anterior to posterior dimension of the globe in 40 eyes were 4.1 ± 0.7, 7.7 ± 0.5, 8.2 ± 0.4 and 20.7 ± 1.0 mm, respectively. No significant difference was found between the ocular biometry of the left and right eyes or the horizontal and vertical planes. Of the ocular parameters, the following had a significant positive correlation with head circumference: axial globe length, anterior chamber and lens thickness. The vitreous body had a positive correlation with age. Regarding the breed predisposition of Persian cats to ocular problems, the present study provides baseline information for further clinical investigations of ocular abnormalities using B-mode ultrasonography. © 2014 Australian Veterinary Association.

  9. Eye muscle proprioception is represented bilaterally in the sensorimotor cortex

    DEFF Research Database (Denmark)

    Balslev, Daniela; Albert, Neil B; Miall, Chris

    2011-01-01

    eye after a virtual lesion with rTMS over the left somatosensory area. However, it is possible that the proprioceptive representation of the EOM extends to other brain sites, which were not examined in these previous studies. The aim of this fMRI study was to sample the whole brain to identify...... the proprioceptive representation for the left and the right eye separately. Data were acquired while passive eye movement was used to stimulate EOM proprioceptors in the absence of a motor command. We also controlled for the tactile stimulation of the eyelid by removing from the analysis voxels activated by eyelid......The cortical representation of eye position is still uncertain. In the monkey a proprioceptive representation of the extraocular muscles (EOM) of an eye were recently found within the contralateral central sulcus. In humans, we have previously shown a change in the perceived position of the right...

  10. Corneal permeability changes in dry eye disease: an observational study.

    Science.gov (United States)

    Fujitani, Kenji; Gadaria, Neha; Lee, Kyu-In; Barry, Brendan; Asbell, Penny

    2016-05-13

    Diagnostic tests for dry eye disease (DED), including ocular surface disease index (OSDI), tear breakup time (TBUT), corneal fluorescein staining, and lissamine staining, have great deal of variability. We investigated whether fluorophotometry correlated with previously established DED diagnostic tests and whether it could serve as a novel objective metric to evaluate DED. Dry eye patients who have had established signs or symptoms for at least 6 months were included in this observational study. Normal subjects with no symptoms of dry eyes served as controls. Each eye had a baseline fluorescein scan prior to any fluorescein dye. Fluorescein dye was then placed into both eyes, rinsed with saline solution, and scanned at 5, 10, 15, and 30 min. Patients were administered the following diagnostic tests to correlate with fluorophotometry: OSDI, TBUT, fluorescein, and lissamine. Standard protocols were used. P eyes from 25 patients (DED = 22 eyes, 11 patients; Normal = 28 eyes, 14 patients) were included. Baseline scans of the dry eye and control groups did not show any statistical difference (p = 0.84). Fluorescein concentration of DED and normal patients showed statistical significance at all time intervals (p eyes up to 30 min after fluorescein dye instillation. There may be an aspect of DED that is missed in the current regimen of DED tests and only captured with fluorophotometry. Adding fluorophotometry may be useful in screening, diagnosing, and monitoring patients with DED.

  11. Radiation dose to physicians’ eye lens during interventional radiology

    International Nuclear Information System (INIS)

    Bahruddin, N A; Hashim, S; Karim, M K A; Ang, W C; Salehhon, N; Sabarudin, A; Bakar, K A

    2016-01-01

    The demand of interventional radiology has increased, leading to significant risk of radiation where eye lens dose assessment becomes a major concern. In this study, we investigate physicians' eye lens doses during interventional procedures. Measurement were made using TLD-100 (LiF: Mg, Ti) dosimeters and was recorded in equivalent dose at a depth of 0.07 mm, Hp(0.07). Annual Hp(0.07) and annual effective dose were estimated using workload estimation for a year and Von Boetticher algorithm. Our results showed the mean Hp(0.07) dose of 0.33 mSv and 0.20 mSv for left and right eye lens respectively. The highest estimated annual eye lens dose was 29.33 mSv per year, recorded on left eye lens during fistulogram procedure. Five physicians had exceeded 20 mSv dose limit as recommended by international commission of radiological protection (ICRP). It is suggested that frequent training and education on occupational radiation exposure are necessary to increase knowledge and awareness of the physicians’ thus reducing dose during the interventional procedure. (paper)

  12. Extremity and eye lens dosimetry for medical staff performing vertebroplasty and kyphoplasty procedures

    International Nuclear Information System (INIS)

    Struelens, L; Schoonjans, W; Vanhavere, F; Schils, F; De Smedt, K

    2013-01-01

    Measurements of doses to hands, legs and eyes are reported for operators in four different hospitals performing vertebroplasty or kyphoplasty. The results confirm that occupational doses can be high for interventional spine procedures. Extremity and eye lens doses were measured with thermoluminescent dosimeters positioned on the ring fingers, wrists, legs and near the eyes of interventional radiologists and neurosurgeons, over a period of 15 months. Doses were generally larger on the left side for all positions monitored. The median dose to the left finger was 225 μSv per procedure, although a maximum of 7.3 mSv was found. The median dose to the right finger was 118 μSv, but with an even higher maximum of 7.7 mSv. A median left eye dose of 34 μSv (maximum 836 μSv) was found, while the legs received the lowest doses with a median of 13 μSv (maximum 332 μSv) to the left leg. Annual dose to the hand assessed by the cumulated doses almost reached the annual dose limit of 500 mSv, while annual dose to the eyes exceeded the eye lens dose limit of 20 mSv yr −1 . Different x-ray systems and radiation protection measures were tested, like the use of lead gloves and glasses, tweezers, cement delivery systems and a magnetic navigation system. These measurements showed that doses can be significantly reduced. The use of lead glasses is strongly recommended for protection of the eyes. (paper)

  13. Visual information transfer. Part 1: Assessment of specific information needs. Part 2: Parameters of appropriate instrument scanning behavior

    Science.gov (United States)

    Comstock, J. R., Jr.; Kirby, R. H.; Coates, G. D.

    1985-01-01

    The present study explored eye scan behavior as a function of level of subject training. Oculometric (eye scan) measures were recorded from each of ten subjects during training trials on a CRT based flight simulation task. The task developed for the study incorporated subtasks representative of specific activities performed by pilots, but which could be performed at asymptotic levels within relatively short periods of training. Changes in eye scan behavior were examined as initially untrained subjects developed skill in the task. Eye scan predictors of performance on the task were found. Examination of eye scan in proximity to selected task events revealed differences in the distribution of looks at the instruments as a function of level of training.

  14. Study of the structure of buffalo's eye lens and scleroretinal rim in Tabriz by ultrasonography

    Directory of Open Access Journals (Sweden)

    GH Assadnassab

    2011-05-01

    Full Text Available In this study, ultrasonographic condition of lens and posterior wall of buffalo's eye in Tabriz area were investigated due to their important role in vision and also measurements were made in anterior-posterior axial B-mode display methods. The ultrasonographic images were similar to the images obtained from other particularly the cow. Total thickness of the lens was 1.133 ± 0.052 cm with the thickness being 1.135 ± 0.052 cm in the right eye and 1.132 ± 0.053 cm in the left eye. Thickness of the posterior wall of the right and left eyes were 1.677 ± 0.042 mm and 1.672 ± 0.041 mm respectively with the total thickness of the posterior wall measuring 1.674 ± 0.040 mm. There was no significant difference between the left and right eyes regarding these parameters.

  15. A CASE OF SELF-INDUCED ACUTE HYDROPS IN A PATIENT WITH IMPULSE CONTROL DISORDER ASSOCIATED WITH COMPULSIVE EYE TRAUMA

    OpenAIRE

    Bindu Madhavi; Soumya

    2016-01-01

    PURPOSE To describe acute hydrops in a patient with impulse control disorder (not otherwise specified) secondary to self-induced repetitive eye trauma. METHODS A 22-year-old male patient was referred from a psychiatrist with a diagnosis of impulse control disorder not otherwise specified (compulsive impulse self-mutilating behaviour) for opacity and watering of both eyes (left eye more than right eye). Left eye showed features of acute hydrops with Descemet’s tear and rig...

  16. Retinitis pigmentosa inversa with unilateral high myopia with fellow eye optic disc pitting.

    Science.gov (United States)

    Sheth, Saumil; Rush, Ryan; Narayanan, Raja

    2011-01-01

    To report a possible rare association of bilateral retinitis pigmentosa inversa (RPI) with unilateral high myopia with fellow eye optic disc pitting. A 55-year-old man with a history of reduced vision in the right eye since childhood presented with gradually decreasing vision in the left eye. On examination, a -23.00 diopter refractive error and diffuse chorioretinal atrophy consistent with pathologic myopia was found in the right eye. An optic disc pit with posterior pole pigmentary alterations thought to be consequent to a previous neurosensory detachment was found in the left eye. Though the retinal arteriolar attenuation seen in both eyes with an inconsistent history of night blindness since childhood pointed towards the possibility of a concurrently existing rod or rod-cone dystrophy, the posterior pole pigmentary alterations characteristic of RPI were clearly masked by the above pathologies. Optical coherence tomography demonstrated prominent foveal atrophy and an optic disc pit in the left eye. Electroretinography (ERG) demonstrated moderately attenuated amplitudes with prolonged implicit times of rod and cone responses bilaterally. The patient was diagnosed with bilateral RPI and anisometropic amblyopia in the right eye. This report documents a unique constellation of findings which include bilateral RPI and unilateral high myopia with an optic disc pit in the fellow eye. An ERG confirmation of a dystrophic etiology should be sought in suspicious cases, especially when findings are masked by the concurrent presence of other pathologies.

  17. Beware the left-sided gallbladder

    African Journals Online (AJOL)

    An abdominal ultrasound scan showed multiple stones in the gallbladder with no evidence of acute cholecystitis and a common bile duct (CBD) diameter of 4 mm. Owing to the atypical nature of her pain, a computed tomography (CT) scan was requested which showed a left-sided gallbladder containing gallstones (Fig. 1).

  18. Loop myopexy with true muscle transplantation for very large angle heavy eye syndrome patient

    Directory of Open Access Journals (Sweden)

    Jitendra Jethani

    2015-01-01

    Full Text Available A 42-year-old man presenting with complaints of squint for last 20 years. His visual acuity was 20/400 in right eye (RE and 20/30 in left eye (LE with glasses. His refraction was RE -16.75/-2.5 D cycl 180 and LE was -14.5/-1.5 D cycl 180. His axial length was 31.23 mm In RE and 29.72 mm in LE. On examination we found he had RE large esotropia with hypotropia measuring 130 pd base out and 40 pd base up in RE. A computerized tomography scan revealed that the superior rectus (SR was shifted nasally, and lateral rectus (LR was shifted inferiorly. A RE medial rectus (MR recession and LR resection with muscle transplantation on the MR was done. A loop myopexy was done to correct the path of the LR and SR. The patient had only 18 pd eso and 20 pd hypo on follow-up after 3 months. Loop myopexy in conjunction with muscle transplantation is a safe and effective procedure for large angle esotropia associated with heavy eye syndrome.

  19. Intraocular eyelashes and iris cyst in anterior chamber following penetrating eye injury: a case report

    Directory of Open Access Journals (Sweden)

    Sahu S

    2017-03-01

    Full Text Available Sabin Sahu,1 Lila Raj Puri,1 Sanjay Kumar Singh2 1Department of Ophthalmology, Sagarmatha Choudhary Eye Hospital, Lahan, Siraha, 2Department of Ophthalmology, Biratnagar Eye Hospital, Biratnagar, Nepal Background: The presence of intraocular eyelashes following penetrating eye injury or ocular surgery is relatively uncommon. The response of the eye to intraocular eyelashes is variable. The eyelash may be symptomatic or may remain asymptomatic for long periods. Objective: We report a case with two intraocular eyelashes and an iris cyst after 2 years of asymptomatic period following penetrating eye injury. Case presentation: A 24-year-old male presented with decreased vision in the left eye which he had noticed for the previous 2 weeks. His visual acuity was 6/6 in the right eye and 6/18 in the left eye, improving to 6/9 with -2.5 DC × 140° correction. The intraocular pressure was 12 mmHg in both eyes. On slit-lamp examination, the left eye showed 8 mm linear peripheral corneal opacity nasally, two eyelashes in the superior anterior chamber, and an iris cyst measuring 4 mm × 4 mm in the superior iris. The right eye was normal. Dilated fundus examination of both eyes was normal. The eyelashes and cyst were removed surgically. There were no complications during the 3-month follow-up period. Conclusion: Intraocular implantation of eyelashes following penetrating eye injury can remain asymptomatic for long periods; however, late development of iris cyst may occur. Keywords: intraocular eyelashes, iris cyst, penetrating eye injury

  20. Volumetric gain of the human pancreas after left partial pancreatic resection: A CT-scan based retrospective study.

    Science.gov (United States)

    Phillip, Veit; Zahel, Tina; Danninger, Assiye; Erkan, Mert; Dobritz, Martin; Steiner, Jörg M; Kleeff, Jörg; Schmid, Roland M; Algül, Hana

    2015-01-01

    Regeneration of the pancreas has been well characterized in animal models. However, there are conflicting data on the regenerative capacity of the human pancreas. The aim of the present study was to assess the regenerative capacity of the human pancreas. In a retrospective study, data from patients undergoing left partial pancreatic resection at a single center were eligible for inclusion (n = 185). Volumetry was performed based on 5 mm CT-scans acquired through a 256-slice CT-scanner using a semi-automated software. Data from 24 patients (15 males/9 females) were included. Mean ± SD age was 68 ± 11 years (range, 40-85 years). Median time between surgery and the 1st postoperative CT was 9 days (range, 0-27 days; IQR, 7-13), 55 days (range, 21-141 days; IQR, 34-105) until the 2nd CT, and 191 days (range, 62-1902; IQR, 156-347) until the 3rd CT. The pancreatic volumes differed significantly between the first and the second postoperative CT scans (median volume 25.6 mL and 30.6 mL, respectively; p = 0.008) and had significantly increased further by the 3rd CT scan (median volume 37.9 mL; p = 0.001 for comparison with 1st CT scan and p = 0.003 for comparison with 2nd CT scan). The human pancreas shows a measurable and considerable potential of volumetric gain after partial resection. Multidetector-CT based semi-automated volume analysis is a feasible method for follow-up of the volume of the remaining pancreatic parenchyma after partial pancreatectomy. Effects on exocrine and endocrine pancreatic function have to be evaluated in a prospective manner. Copyright © 2015 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  1. Lateralization of visually guided detour behaviour in the common chameleon, Chamaeleo chameleon, a reptile with highly independent eye movements.

    Science.gov (United States)

    Lustig, Avichai; Ketter-Katz, Hadas; Katzir, Gadi

    2013-11-01

    Chameleons (Chamaeleonidae, reptilia), in common with most ectotherms, show full optic nerve decussation and sparse inter-hemispheric commissures. Chameleons are unique in their capacity for highly independent, large-amplitude eye movements. We address the question: Do common chameleons, Chamaeleo chameleon, during detour, show patterns of lateralization of motion and of eye use that differ from those shown by other ectotherms? To reach a target (prey) in passing an obstacle in a Y-maze, chameleons were required to make a left or a right detour. We analyzed the direction of detours and eye use and found that: (i) individuals differed in their preferred detour direction, (ii) eye use was lateralized at the group level, with significantly longer durations of viewing the target with the right eye, compared with the left eye, (iii) during left side, but not during right side, detours the durations of viewing the target with the right eye were significantly longer than the durations with the left eye. Thus, despite the uniqueness of chameleons' visual system, they display patterns of lateralization of motion and of eye use, typical of other ectotherms. These findings are discussed in relation to hemispheric functions. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Computed tomography and histopathological findings in pseudotumors of the orbit

    International Nuclear Information System (INIS)

    Ishibashi, Yasuhiko; Watanabe, Takao; Yoshimoto, Takashi; Suzuki, Jiro

    1981-01-01

    The CT scan findings of 4 cases of orbital tumor, in which transcranial orbital decompression was performed because of no improvement by medication, were reported. The first case was a 71-year-old female with exophthalmos, decreased vision and ocular movement disturbance of the left eye. CT scan demonstrated an abnormal high density area in the left retrobulbar region with a thickened medial rectal muscle. Specimens were taken from a thickened medial rectal muscle. The histological examination revealed angitis. The second case was a 38-year-old female with exophthalmos, blepharoptosis, chemosis, decreased vision and ocular movement disturbance of the left eye. CT scan showed exophthalmos of the left eye, but no focal abnormality. Specimens were taken from fatty tissue-in the left retrobulbar region. The histological examination revealed no abnormal inflammatory changes. The third case was a 37-year-old female with orbital pain, exophthalmos and ocular movement disturbance of the right eye. CT scan demonstrated a growing abnormal high density area in the right retrobulbar region. Specimens were taken from the abnormal tissue in the right retrobulbar region. The histological examination revealed inflammatory changes of muscle and nerve. The forth case was a 61-year-old male with diplopia and exophthalmos. CT scan demonstrated an abnormal high density area in the left retrobulbar region. Specimens were taken from an abnormal tissue in the left retrobulbar region lying against the lateral wall of the orbit. The histological examination revealed severe infiltrations with lymphocytes and plasma cells. Transcranial orbital decompression improved the exophthalmos and ocular movement in all cases. (author)

  3. Computed tomography and histopathological findings in pseudotumors of the orbit

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Y.; Watanabe, T.; Yoshimoto, T.; Suzuki, J. (Tohoku Univ., Sendai (Japan). School of Medicine)

    1981-09-01

    The CT scan findings of 4 cases of orbital tumor, in which transcranial orbital decompression was performed because of no improvement by medication, were reported. The first case was a 71-year-old female with exophthalmos, decreased vision and ocular movement disturbance of the left eye. CT scan demonstrated an abnormal high density area in the left retrobulbar region with a thickened medial rectal muscle. Specimens were taken from a thickened medial rectal muscle. The histological examination revealed angitis. The second case was a 38-year-old female with exophthalmos, blepharoptosis, chemosis, decreased vision and ocular movement disturbance of the left eye. CT scan showed exophthalmos of the left eye, but no focal abnormality. Specimens were taken from fatty tissue in the left retrobulbar region. The histological examination revealed no abnormal inflammatory changes. The third case was a 37-year-old female with orbital pain, exophthalmos and ocular movement disturbance of the right eye. CT scan demonstrated a growing abnormal high density area in the right retrobulbar region. Specimens were taken from the abnormal tissue in the right retrobulbar region. The histological examination revealed inflammatory changes of muscle and nerve. The forth case was a 61-year-old male with diplopia and exophthalmos. CT scan demonstrated an abnormal high density area in the left retrobulbar region. Specimens were taken from an abnormal tissue in the left retrobulbar region lying against the lateral wall of the orbit. The histological examination revealed severe infiltrations with lymphocytes and plasma cells. Transcranial orbital decompression improved the exophthalmos and ocular movement in all cases.

  4. Visual recovery from optic atrophy following acute optic neuropathy in the fellow eye.

    Science.gov (United States)

    Ornek, Kemal; Ornek, Nurgül

    2012-06-01

    The left eye of a 65-year-old male was blind due to optic atrophy and only seeing eye had also dry type age-related macular degeneration. An anterior ischemic optic neuropathy developed in the better seeing eye. Vision recovered in the blind eye in a short time after losing the better eye. Gaining some vision in a blind eye may be an adaptation of visual pathway in such patients.

  5. Coats' disease in Tanzania: first case report and literature review

    African Journals Online (AJOL)

    Brain and orbits scan revealed no residual tumour. The globe measured ... which necessitates eye enucleation as was in this child. Keywords: ... B-scan ultrasound showed left eye posterior mass. The right eye and other systems were normal. .... ultrasonography) clinical manifestation. Sex ratio. Male: Female > 3:1. (2; 6).

  6. Schwannoma of the left brachial plexus mimicking a ...

    African Journals Online (AJOL)

    Schwannoma of the left brachial plexus mimicking a cervicomediastinal ... Her voice was hoarse but there was no eye signs suggestive of thyrotoxicosis. ... A presumptive diagnosis of thyroid carcinoma with retrosternal extension was made.

  7. Hawk eyes II: diurnal raptors differ in head movement strategies when scanning from perches.

    Science.gov (United States)

    O'Rourke, Colleen T; Pitlik, Todd; Hoover, Melissa; Fernández-Juricic, Esteban

    2010-09-22

    Relatively little is known about the degree of inter-specific variability in visual scanning strategies in species with laterally placed eyes (e.g., birds). This is relevant because many species detect prey while perching; therefore, head movement behavior may be an indicator of prey detection rate, a central parameter in foraging models. We studied head movement strategies in three diurnal raptors belonging to the Accipitridae and Falconidae families. We used behavioral recording of individuals under field and captive conditions to calculate the rate of two types of head movements and the interval between consecutive head movements. Cooper's Hawks had the highest rate of regular head movements, which can facilitate tracking prey items in the visually cluttered environment they inhabit (e.g., forested habitats). On the other hand, Red-tailed Hawks showed long intervals between consecutive head movements, which is consistent with prey searching in less visually obstructed environments (e.g., open habitats) and with detecting prey movement from a distance with their central foveae. Finally, American Kestrels have the highest rates of translational head movements (vertical or frontal displacements of the head keeping the bill in the same direction), which have been associated with depth perception through motion parallax. Higher translational head movement rates may be a strategy to compensate for the reduced degree of eye movement of this species. Cooper's Hawks, Red-tailed Hawks, and American Kestrels use both regular and translational head movements, but to different extents. We conclude that these diurnal raptors have species-specific strategies to gather visual information while perching. These strategies may optimize prey search and detection with different visual systems in habitat types with different degrees of visual obstruction.

  8. Scan path entropy and Arrow plots: Capturing scanning behavior of multiple observers

    Directory of Open Access Journals (Sweden)

    Ignace T C Hooge

    2013-12-01

    Full Text Available Designers of visual communication material want their material to attract and retain attention. In marketing research, heat maps, dwell time, and time to AOI first hit are often used as evaluation parameters. Here we present two additional measures 1 scan path entropy to quantify gaze guidance and 2 the arrow plot to visualize the average scan path. Both are based on string representations of scan paths. The latter also incorporates transition matrices and time required for 50% of the observers to first hit AOIs (T50. The new measures were tested in an eye tracking study (48 observers, 39 advertisements. Scan path entropy is a sensible measure for gaze guidance and the new visualization method reveals aspects of the average scan path and gives a better indication in what order global scanning takes place.

  9. The retinal nerve fibre layer thickness in glaucomatous hydrophthalmic eyes assessed by scanning laser polarimetry with variable corneal compensation in comparison with age-matched healthy children.

    Science.gov (United States)

    Hložánek, Martin; Ošmera, Jakub; Ležatková, Pavlína; Sedláčková, Petra; Filouš, Aleš

    2012-12-01

    To compare the thickness of the retinal nerve fibre layer (RNFL) in hydrophthalmic glaucomatous eyes in children with age-matched healthy controls using scanning laser polarimetry with variable corneal compensation (GDxVCC). Twenty hydrophthalmic eyes of 20 patients with the mean age of 10.64 ± 3.02 years being treated for congenital or infantile glaucoma were included in the analysis. Evaluation of RNFL thickness measured by GDxVCC in standard Temporal-Superior-Nasal-Inferior-Temporal (TSNIT) parameters was performed. The results were compared to TSNIT values of an age-matched control group of 120 healthy children published recently as referential values. The correlation between horizontal corneal diameter and RNFL thickness in hydrophthalmic eyes was also investigated. The mean ± SD values in TSNIT Average, Superior Average, Inferior Average and TSNIT SD in hydrophthalmic eyes were 52.3 ± 11.4, 59.7 ± 17.1, 62.0 ± 15.6 and 20.0 ± 7.8 μm, respectively. All these values were significantly lower compared to referential TSNIT parameters of age-matched healthy eyes (p = 0.021, p = 0.001, p = 0.003 and p = 0.018, respectively). A substantial number of hydrophthalmic eyes laid below the level of 5% probability of normality in respective TSNIT parameters: 30% of the eyes in TSNIT average, 50% of the eyes in superior average, 30% of the eyes in inferior average and 45% of the eyes in TSNIT SD. No significant correlation between enlarged corneal diameter and RNFL thickness was found. The mean values of all standard TSNIT parameters assessed using GDxVCC in hydrophthalmic glaucomatous eyes in children were significantly lower in comparison with referential values of healthy age-matched children. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  10. Interhemispheric Transfer Time Asymmetry of Visual Information Depends on Eye Dominance: An Electrophysiological Study

    Directory of Open Access Journals (Sweden)

    Romain Chaumillon

    2018-02-01

    Full Text Available The interhemispheric transfer of information is a fundamental process in the human brain. When a visual stimulus appears eccentrically in one visual-hemifield, it will first activate the contralateral hemisphere but also the ipsilateral one with a slight delay due to the interhemispheric transfer. This interhemispheric transfer of visual information is believed to be faster from the right to the left hemisphere in right-handers. Such an asymmetry is considered as a relevant fact in the context of the lateralization of the human brain. We show here using current source density (CSD analyses of visually evoked potential (VEP that, in right-handers and, to a lesser extent in left-handers, this asymmetry is in fact dependent on the sighting eye dominance, the tendency we have to prefer one eye for monocular tasks. Indeed, in right-handers, a faster interhemispheric transfer of visual information from the right to left hemisphere was observed only in participants with a right dominant eye (DE. Right-handers with a left DE showed the opposite pattern, with a faster transfer from the left to the right hemisphere. In left-handers, albeit a smaller number of participants has been tested and hence confirmation is required, only those with a right DE showed an asymmetrical interhemispheric transfer with a faster transfer from the right to the left hemisphere. As a whole these results demonstrate that eye dominance is a fundamental determinant of asymmetries in interhemispheric transfer of visual information and suggest that it is an important factor of brain lateralization.

  11. Interhemispheric Transfer Time Asymmetry of Visual Information Depends on Eye Dominance: An Electrophysiological Study.

    Science.gov (United States)

    Chaumillon, Romain; Blouin, Jean; Guillaume, Alain

    2018-01-01

    The interhemispheric transfer of information is a fundamental process in the human brain. When a visual stimulus appears eccentrically in one visual-hemifield, it will first activate the contralateral hemisphere but also the ipsilateral one with a slight delay due to the interhemispheric transfer. This interhemispheric transfer of visual information is believed to be faster from the right to the left hemisphere in right-handers. Such an asymmetry is considered as a relevant fact in the context of the lateralization of the human brain. We show here using current source density (CSD) analyses of visually evoked potential (VEP) that, in right-handers and, to a lesser extent in left-handers, this asymmetry is in fact dependent on the sighting eye dominance, the tendency we have to prefer one eye for monocular tasks. Indeed, in right-handers, a faster interhemispheric transfer of visual information from the right to left hemisphere was observed only in participants with a right dominant eye (DE). Right-handers with a left DE showed the opposite pattern, with a faster transfer from the left to the right hemisphere. In left-handers, albeit a smaller number of participants has been tested and hence confirmation is required, only those with a right DE showed an asymmetrical interhemispheric transfer with a faster transfer from the right to the left hemisphere. As a whole these results demonstrate that eye dominance is a fundamental determinant of asymmetries in interhemispheric transfer of visual information and suggest that it is an important factor of brain lateralization.

  12. Interhemispheric Transfer Time Asymmetry of Visual Information Depends on Eye Dominance: An Electrophysiological Study

    Science.gov (United States)

    Chaumillon, Romain; Blouin, Jean; Guillaume, Alain

    2018-01-01

    The interhemispheric transfer of information is a fundamental process in the human brain. When a visual stimulus appears eccentrically in one visual-hemifield, it will first activate the contralateral hemisphere but also the ipsilateral one with a slight delay due to the interhemispheric transfer. This interhemispheric transfer of visual information is believed to be faster from the right to the left hemisphere in right-handers. Such an asymmetry is considered as a relevant fact in the context of the lateralization of the human brain. We show here using current source density (CSD) analyses of visually evoked potential (VEP) that, in right-handers and, to a lesser extent in left-handers, this asymmetry is in fact dependent on the sighting eye dominance, the tendency we have to prefer one eye for monocular tasks. Indeed, in right-handers, a faster interhemispheric transfer of visual information from the right to left hemisphere was observed only in participants with a right dominant eye (DE). Right-handers with a left DE showed the opposite pattern, with a faster transfer from the left to the right hemisphere. In left-handers, albeit a smaller number of participants has been tested and hence confirmation is required, only those with a right DE showed an asymmetrical interhemispheric transfer with a faster transfer from the right to the left hemisphere. As a whole these results demonstrate that eye dominance is a fundamental determinant of asymmetries in interhemispheric transfer of visual information and suggest that it is an important factor of brain lateralization. PMID:29515351

  13. Orienting of attention via observed eye gaze is head-centred.

    Science.gov (United States)

    Bayliss, Andrew P; di Pellegrino, Giuseppe; Tipper, Steven P

    2004-11-01

    Observing averted eye gaze results in the automatic allocation of attention to the gazed-at location. The role of the orientation of the face that produces the gaze cue was investigated. The eyes in the face could look left or right in a head-centred frame, but the face itself could be oriented 90 degrees clockwise or anticlockwise such that the eyes were gazing up or down. Significant cueing effects to targets presented to the left or right of the screen were found in these head orientation conditions. This suggests that attention was directed to the side to which the eyes would have been looking towards, had the face been presented upright. This finding provides evidence that head orientation can affect gaze following, even when the head orientation alone is not a social cue. It also shows that the mechanism responsible for the allocation of attention following a gaze cue can be influenced by intrinsic object-based (i.e. head-centred) properties of the task-irrelevant cue.

  14. Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction

    International Nuclear Information System (INIS)

    Raissaki, Maria; Perisinakis, Kostas; Damilakis, John; Gourtsoyiannis, Nicholas

    2010-01-01

    CT scans of the brain, sinuses and petrous bones performed as the initial imaging test for a variety of indications have the potential to expose the eye-lens, considered among the most radiosensitive human tissues, to a radiation dose. There are several studies in adults discussing the reduction of orbital dose resulting from the use of commercially available bismuth-impregnated latex shields during CT examinations of the head. To evaluate bismuth shielding-induced artefacts and to provide suggestions for optimal eye-lens shielding in paediatric head CT. A bismuth shield was placed over the eyelids of 60 consecutive children undergoing head CT. Images were assessed for the presence and severity of artefacts with regard to eye-shield distance and shield wrinkling. An anthropomorphic paediatric phantom and thermoluminescence dosimeters (TLDs) were used to study the effect of eye lens-to-shield distance on shielding efficiency. Shields were tolerated by 56/60 children. Artefacts were absent in 45% of scans. Artefacts on orbits, not affecting and affecting orbit evaluation were noted in 39% and 14% of scans, respectively. Diagnostically insignificant artefacts on intracranial structures were noted in 1 case (2%) with shield misplacement. Mean eye-lens-to-shield distance was 8.8 mm in scans without artefacts, and 4.3 mm and 2.2 mm in scans with unimportant and diagnostically important artefacts, respectively. Artefacts occurred in 8 out of 9 cases with shield wrinkling. Dose reduction remained unchanged for different shield-to-eye distances. Bismuth shielding-related artefacts occurring in paediatric head CT are frequent, superficial and diagnostically insignificant when brain pathology is assessed. Shields should be placed 1 cm above the eyes when orbital pathology is addressed. Shield wrinkling should be avoided. (orig.)

  15. Hidden Markov model analysis reveals the advantage of analytic eye movement patterns in face recognition across cultures.

    Science.gov (United States)

    Chuk, Tim; Crookes, Kate; Hayward, William G; Chan, Antoni B; Hsiao, Janet H

    2017-12-01

    It remains controversial whether culture modulates eye movement behavior in face recognition. Inconsistent results have been reported regarding whether cultural differences in eye movement patterns exist, whether these differences affect recognition performance, and whether participants use similar eye movement patterns when viewing faces from different ethnicities. These inconsistencies may be due to substantial individual differences in eye movement patterns within a cultural group. Here we addressed this issue by conducting individual-level eye movement data analysis using hidden Markov models (HMMs). Each individual's eye movements were modeled with an HMM. We clustered the individual HMMs according to their similarities and discovered three common patterns in both Asian and Caucasian participants: holistic (looking mostly at the face center), left-eye-biased analytic (looking mostly at the two individual eyes in addition to the face center with a slight bias to the left eye), and right-eye-based analytic (looking mostly at the right eye in addition to the face center). The frequency of participants adopting the three patterns did not differ significantly between Asians and Caucasians, suggesting little modulation from culture. Significantly more participants (75%) showed similar eye movement patterns when viewing own- and other-race faces than different patterns. Most importantly, participants with left-eye-biased analytic patterns performed significantly better than those using either holistic or right-eye-biased analytic patterns. These results suggest that active retrieval of facial feature information through an analytic eye movement pattern may be optimal for face recognition regardless of culture. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. A CASE OF SELF-INDUCED ACUTE HYDROPS IN A PATIENT WITH IMPULSE CONTROL DISORDER ASSOCIATED WITH COMPULSIVE EYE TRAUMA

    Directory of Open Access Journals (Sweden)

    Bindu Madhavi

    2016-03-01

    Full Text Available PURPOSE To describe acute hydrops in a patient with impulse control disorder (not otherwise specified secondary to self-induced repetitive eye trauma. METHODS A 22-year-old male patient was referred from a psychiatrist with a diagnosis of impulse control disorder not otherwise specified (compulsive impulse self-mutilating behaviour for opacity and watering of both eyes (left eye more than right eye. Left eye showed features of acute hydrops with Descemet’s tear and right eye showed corneal opacity with Descemet’s tear (status post hydrops. RESULT The patient was prescribed cycloplegics, hypertonic saline for left eye and was advised against scratching the eye and was given protective goggles and was told for close followup in conjunction with psychiatric management. CONCLUSION Impulse control disorders are relatively common psychiatric conditions, yet are poorly understood by clinicians, patients suffering from the disorder and public. And hence identification of this disorder and close observation of patient allows for avoiding complications such as progression of hydrops, perforation and infection.

  17. Ocular volume measured by CT scans

    International Nuclear Information System (INIS)

    Hahn, F.J.; Wei-Kom Chu

    1984-01-01

    Newer CT scans have greatly enhanced oculometric research and made it possible to measure ocular dimensions. With these measurements, ocular volume can be more accurately estimated to understand its relationship with age and sex. One hundred CT orbit scans with presumed normal eyes were used for the data base. The mean values and normal variations of ocular volumes at various ages in both sexes are presented. Rapid growth of the eyeball was noted during the first 24 months of age. It reached its peak between the ages of 18 and 30 years of age, after which there was a reduction. Results may be of help in recognizing eye abnormalities such as microophthalmus and macrophthalmia. (orig.)

  18. Transcutaneous periorbital electrical stimulation in the treatment of dry eye.

    Science.gov (United States)

    Pedrotti, Emilio; Bosello, Francesca; Fasolo, Adriano; Frigo, Anna C; Marchesoni, Ivan; Ruggeri, Alfredo; Marchini, Giorgio

    2017-06-01

    To evaluate efficacy and safety of transcutaneous application of electrical current on symptoms and clinical signs of dry eye (DE). 27 patients with DE underwent transcutaneous electrostimulation with electrodes placed onto the periorbital region of both eyes and manual stimulation with a hand-piece conductor moved by the operator. Each patient underwent 12 sessions of 22 min spread over 2 months, two sessions per week in the first month and one session per week in the second month. Ocular Surface Disease Index (OSDI) questionnaire, tear break-up time (TBUT), fluorescein staining of the cornea, Schirmer I test and adverse events were evaluated at baseline, at end of treatment and at 6 and 12 months. OSDI improved from 43.0±19.2 at baseline to 25.3±22.1 at end of treatment (mean±SD, p=0.001). These effects were substantially maintained at 6-month and 12-month follow-up evaluations. Improvement of the values of TBUT was recorded for the right eye at the end of treatment (p=0.003) and found in the left eye after 12 months (p=0.02). The Oxford scores changed in both eyes at the end of treatment and at the 6-month evaluation (peye at the 12-month evaluation (p=0.035). Schirmer I improved significantly at the end of treatment in the left eye (p=0.001) and in both eyes at the 12-month evaluation (p=0.004 and p=0.039 for the left and right eye, respectively). A significant reduction of the use of tear substitutes was found at the end of treatment (p=0.003), and was maintained during the follow-up (ptreatment satisfying. Transcutaneous electrical stimulation was shown to improve DE, both subjectively and objectively, without any adverse effects and has the potential to enlarge the armamentarium for treating DE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Eye dose assessment and management: overview

    International Nuclear Information System (INIS)

    Rehani, M.M.

    2015-01-01

    Some publications have shown that Hp( 0.07 ) or even Hp( 10 ) can be used as good operational quantities for X-rays in view of difficulties with Hp( 3 ). With increasing awareness, there is tendency to use whatever dosimeter is available with correction factor to estimate eye lens dose. The best position for an eye lens dosimeter has been reported to be at the side of the head nearest to the radiation source, close to the eye. Recent studies have reported eye doses with cone beam CT (CBCT) both for patients and staff, and there are many papers reporting eye lens doses to staff in nuclear medicine. To minimise the dose to eyes, the user can take advantage of a feature of CBCT of projections acquired over an angular span of 1808 plus cone angle of the X-ray tube and with tube under scan arcs. (authors)

  20. Scleral wound healing with cross-link technique using riboflavin and ultraviolet A on rabbit eyes

    Directory of Open Access Journals (Sweden)

    Damasceno NA

    2017-07-01

    Full Text Available Nadyr A Damasceno,1 Nadia C Miguel,2 Marcelo Palis Ventura,3 Miguel Burnier Jr,4 Marcos P Avila,5 Eduardo F Damasceno3 1Ophthalmology Department, Hospital Naval Marcílio Dias, 2Laboratory of Neurohistology and Cell Ultrastructure, Instituto de Ciências Biomédicas, Universidade Federal do Rio de Janeiro, Rio de Janeiro, 3Ophthalmology Department, Universidade Federal Fluminense, Niterói, Brazil; 4Ophthalmology Department, McGill University, Montreal, QC, Canada; 5Ophthalmology Department, Universidade Federal de Goiás, Goiania, Brazil Purpose: The aim of study was to evaluate the cross-link using riboflavin and ultraviolet A (UVA for improving scleral wound healing.Materials and methods: This was an experimental study involving four New Zealand rabbits (eight eyes. Therapy procedure was chosen for the right eye and control procedure for the left one. UVA irradiation of 365 nm with a surface irradiance of 3 mW/cm2 and a photosensitizer of riboflavin drops were applied for 30 minutes on the right eye at 2 mm from the limbus. Sclerotomy incision was performed at 2 mm from the limbus in both right (on the cross-link-treated area and left eye. Then, 30 days after surgery, a morphological analysis and histological staining with hematoxylin–eosin and picrosirius red were performed, and the sclerotomy cicatrization of right and left eyes was compared. The variables investigated were as follows: sclerotomy incision pictures and measurements were made using the ImageJ Software. Scleral thickness was measured (employing the anterior optical coherence tomography and the digital caliper. Collagen fiber density stained with picrosirius red staining was measured using the Image Pro Plus software.Results: The morphological analysis showed that in all samples, the right eye presented sclerotomy closure, and in two eyes, among them, there were no visible edges of the sclerotomies incision. The left eye presented sclerotomy closure and incision edges

  1. Corneal haze following PRK with mitomycin C as a retreatment versus prophylactic use in the contralateral eye.

    Science.gov (United States)

    Netto, Marcelo V; Chalita, Maria Regina; Krueger, Ronald R

    2007-01-01

    To report photorefractive keratectomy (PRK) treated with mitomycin C (MMC) for previous corneal haze in one eye and PRK with MMC to prevent corneal haze formation in the fellow eye. A 40-year-old woman underwent PRK with MMC to treat previous corneal haze (secondary to previous PRK without MMC) for residual refractive error of +0.50 +0.25 x 165 in the left eye and PRK with MMC to prevent corneal haze in the right eye. Postoperative slit-lamp examination revealed no haze in the right eye, but continued mild haze in the left eye. Treatment with PRK and MMC for previous corneal haze is not as effective as primary PRK with MMC in preventing postoperative corneal haze formation.

  2. Measurement of retinal nerve fiber layer thickness in eyes with optic disc swelling by using scanning laser polarimetry and optical coherence tomography.

    Science.gov (United States)

    Hata, Masayuki; Miyamoto, Kazuaki; Oishi, Akio; Kimura, Yugo; Nakagawa, Satoko; Horii, Takahiro; Yoshimura, Nagahisa

    2014-01-01

    The retinal nerve fiber layer thickness (RNFLT) in patients with optic disc swelling of different etiologies was compared using scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (OCT). Forty-seven patients with optic disc swelling participated in the cross-sectional study. Both GDx SLP (enhanced corneal compensation) and Spectralis spectral-domain OCT measurements of RNFLT were made in 19 eyes with papilledema (PE), ten eyes with optic neuritis (ON), and 18 eyes with nonarteritic anterior ischemic optic neuropathy (NAION) at the neuro-ophthalmology clinic at Kyoto University Hospital. Differences in SLP (SLP-RNFLT) and OCT (OCT-RNFLT) measurements among different etiologies were investigated. No statistical differences in average OCT-RNFLT among PE, ON, and NAION patients were noted. Average SLP-RNFLT in NAION patients was smaller than in PE (P<0.01) or ON (P=0.02) patients. When RNFLT in each retinal quadrant was compared, no difference among etiologies was noted on OCT, but on SLP, the superior quadrant was thinner in NAION than in PE (P<0.001) or ON (P=0.001) patients. Compared with age-adjusted normative data of SLP-RNFLT, average SLP-RNFLT in PE (P<0.01) and ON (P<0.01) patients was greater. Superior SLP-RNFLT in NAION patients was smaller (P=0.026). The ratio of average SLP-RNFLT to average OCT-RNFLT was smaller in NAION than in PE (P=0.001) patients. In the setting of RNFL thickening, despite increased light retardance in PE and ON eyes, SLP revealed that NAION eyes have less retardance, possibly associated with ischemic axonal loss.

  3. COMPARISON OF RETINAL PATHOLOGY VISUALIZATION IN MULTISPECTRAL SCANNING LASER IMAGING.

    Science.gov (United States)

    Meshi, Amit; Lin, Tiezhu; Dans, Kunny; Chen, Kevin C; Amador, Manuel; Hasenstab, Kyle; Muftuoglu, Ilkay Kilic; Nudleman, Eric; Chao, Daniel; Bartsch, Dirk-Uwe; Freeman, William R

    2018-03-16

    To compare retinal pathology visualization in multispectral scanning laser ophthalmoscope imaging between the Spectralis and Optos devices. This retrospective cross-sectional study included 42 eyes from 30 patients with age-related macular degeneration (19 eyes), diabetic retinopathy (10 eyes), and epiretinal membrane (13 eyes). All patients underwent retinal imaging with a color fundus camera (broad-spectrum white light), the Spectralis HRA-2 system (3-color monochromatic lasers), and the Optos P200 system (2-color monochromatic lasers). The Optos image was cropped to a similar size as the Spectralis image. Seven masked graders marked retinal pathologies in each image within a 5 × 5 grid that included the macula. The average area with detected retinal pathology in all eyes was larger in the Spectralis images compared with Optos images (32.4% larger, P < 0.0001), mainly because of better visualization of epiretinal membrane and retinal hemorrhage. The average detection rate of age-related macular degeneration and diabetic retinopathy pathologies was similar across the three modalities, whereas epiretinal membrane detection rate was significantly higher in the Spectralis images. Spectralis tricolor multispectral scanning laser ophthalmoscope imaging had higher rate of pathology detection primarily because of better epiretinal membrane and retinal hemorrhage visualization compared with Optos bicolor multispectral scanning laser ophthalmoscope imaging.

  4. CT scans of giant aneurysms in the vertebro-basilar artery

    International Nuclear Information System (INIS)

    Shishido, Toyofumi; Ohsugi, Tamotsu; Motozaki, Takahiko; Sakaki, Saburo; Matsuoka, Kenzo

    1980-01-01

    Clinical course and neurological and neuroradiological findings of giant aneurysms in the vertebro-basilar artery observed in two of our cases were discussed. The first case was a 66-year-old man. He complained of sensory disturbance over his left face and unstable gait for 2 years before admission. Neurological examinations on admission showed hypesthesia in the territory of the second branch of the left fifth cranial nerve, nystagmus, and a left cerebellar sign. No mental deterioration or pyramidal signs were noticed. Retrograde left brachial artery angiograms revealed a giant aneurysm with inferior pointing measuring 30 x 10 mm in diameter arising from the left superior cerebellar artery. Precontrast CT scans demonstrated a round, large, high-density area, cantaining a relatively low-density area within it, in the medioventral portion of the left cerebellum; a part of this high-density area was markedly enhanced in the postcontrast CT scan. No ventricular dilatations were noticed by CT scans. Direct surgery was abandoned due to the size and location of the aneurysm. No neurologically abnormal finding developed after discharge. The second case was a 61-year-old man. He complained of unstable gait for 2 years before admission. Neurological examinations on admission showed bilateral pyramidal sings (more pronounced on the left) and nystagmus. There were no cranial nerve palsy and no sensory disturbances. Precontrast CT scans showed a large, oval, high-density area in the medioventral portion of the right cerebellum, extending to the upper brainstem; a part of this high-density area was markedly enhanced in the postcontrast CT scans. Retrograde left brachial artery angiograms revealed that the fusiform aneurysm in the left vertebral, the basilar artery, and the dilated basilar artery ran 30 mm from the clivus, with a dorsal convex arch. (J.P.N.)

  5. Interventions for disorders of eye movement in patients with stroke

    OpenAIRE

    Pollock, A.; Hazelton, C.; Henderson, C.A.; Angilley, J.; Dhillon, B.; Langhorne, P.; Livingstone, K.; Munro, F.A.; Orr, H.; Rowe, F.J.; Shahani, U.

    2011-01-01

    Background Eye movement disorders may affect over 70% of stroke patients. These eye movement disorders can result in difficulty maintaining the normal ocular position and difficulty moving the eyes appropriately. The resulting functional disabilities include a loss of depth perception, reduced hand-to-eye co-ordination, marked difficulties with near tasks and reading and reduced ability to scan the visual environment. They can also impact on the effectiveness of rehabilitation therapy. There ...

  6. Metastasis of Ciliary Body Melanoma to the Contralateral Eye: A Case Report and Review of Uveal Melanoma Literature

    Directory of Open Access Journals (Sweden)

    Nouritza M. Torossian

    2015-01-01

    Full Text Available Many types of cancers metastasize to the eye. However, uveal melanoma metastasizing to the contralateral choroid is very rare. We report the case of a 68-year-old man with history of treated uveal melanoma of the right eye that developed metastasis to the liver and the choroid of the left eye. Ten years earlier, he was diagnosed to have uveal melanoma of the right eye and was initially treated with plaque radiotherapy. Two years later, upon progression of the disease in the right eye he had enucleation of the eye. We describe the patient’s clinical history, the diagnosis of recurrent disease in the contralateral eye, therapy of the left eye, and systemic metastasis. In addition, we reviewed the published medical literature and described the recent advances in the management of uveal melanoma.

  7. Reliability of Entire Corneal Thickness Mapping in Normal Post-Laser in situ Keratomileusis and Keratoconus Eyes Using Long Scan Depth Spectral Domain Optical Coherence Tomography.

    Science.gov (United States)

    Xu, Zhe; Chen, Sisi; Yang, Chun; Huang, Shenghai; Shen, Meixiao; Wang, Yuanyuan

    2018-01-01

    To investigate the repeatability and reproducibility of mapping the entire corneal thickness using spectral domain optical coherence tomography (SD-OCT). Thirty normal eyes, 30 post-laser in situ keratomileusis (LASIK) surgery eyes, and 30 keratoconus eyes were analyzed. A custom-built long scan depth SD-OCT device was used to obtain entire corneal images. Ten-millimeter-diameter corneal thickness maps were generated by an automated segmentation algorithm. Intraclass correlation coefficients of repeatability (ICC1) and reproducibility (ICC2), and coefficients of repeatability (CoR1) and reproducibility (CoR2), were calculated to quantify the precision and accuracy of corneal pachymetry measurements using the Bland-Altman method. For SD-OCT measurements in healthy subjects, CoR1 and CoR2 were less than 5.00 and 5.53 μm. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in LASIK patients, CoR1 and CoR2 were less than 5.09 and 5.34 μm. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in keratoconus patients, CoR1 and CoR2 were less than 11.57 and 10.92 μm. ICC1 and ICC2 were more than 0.995 and 0.996. The measurements of corneal pachymetric mapping by long scan depth SD-OCT can be assessed over the entire corneal area with good repeatability and reproducibility. © 2017 S. Karger AG, Basel.

  8. Computed tomography in optic neuritis

    International Nuclear Information System (INIS)

    Fujitani, Ken; Hakuba, Akira; Tsujimoto, Takeshi; Yasui, Toshihiro; Sakamoto, Hiroaki

    1979-01-01

    In two patients with optic neuritis, CT scans showed common features which were helpful in diagnosis. These consisted of an enlargement of the optic nerve and an increased density of the optic nerve after contrast infusion. A 49-year-old man was admitted with a two-week duration of pain and a progressive visual loss in his right eye. On admission, an enlarged central scotoma was noted, and only a flashlight was perceived at the periphery in the right eye. The right optic disc was swollen with perivascular bleeding. Plain skull radiographs and orbital tomographs were normal. An orbital CT scan, however, revealed an enlargement of the right optic nerve, the density of which was increased after the infusion of a contrast medium. After steroid therapy, the CT scan showed a normal optic nerve following improvement in the vision of the right eye. A 44-year-old man was referred to this hospital because of a visual loss in his right eye which had been noted one month before. The right eye, with a central scotoma, had only visual acuity enough to perceive hand motion. The right pupil responded poorly to light. The right optic disc was hyperemic. Plain skull radiographs were normal. The orbital CT scan, however, showed an enlargement of the right optic nerve and exhibited contrast enhancement. Steroid therapy resulted in an improvement of the visual disturbance, and a follow-up CT scan showed normal. Two months later, though, the visual acuity had decreased and a visual field defect was noted in his left eye. The orbital CT scan revealed an enlargement of the left optic nerve. The administration of steroid again improved the visual field defect in the left eye, and the CT scan again showed normal. (author)

  9. Automatic three-dimensional model for protontherapy of the eye: Preliminary results

    International Nuclear Information System (INIS)

    Bondiau, Pierre-Yves; Malandain, Gregoire; Chauvel, Pierre; Peyrade, Frederique; Courdi, Adel; Iborra, Nicole; Caujolle, Jean-Pierre; Gastaud, Pierre

    2003-01-01

    Recently, radiotherapy possibilities have been dramatically increased by software and hardware developments. Improvements in medical imaging devices have increased the importance of three-dimensional (3D) images as the complete examination of these data by a physician is not possible. Computer techniques are needed to present only the pertinent information for clinical applications. We describe a technique for an automatic 3D reconstruction of the eye and CT scan merging with fundus photographs (retinography). The final result is a 'virtual eye' to guide ocular tumor protontherapy. First, we make specific software to automatically detect the position of the eyeball, the optical nerve, and the lens in the CT scan. We obtain a 3D eye reconstruction using this automatic method. Second, we describe the retinography and demonstrate the projection of this modality. Then we combine retinography with a reconstructed eye, using a CT scan to get a virtual eye. The result is a computer 3D scene rendering a virtual eye into a skull reconstruction. The virtual eye can be useful for the simulation, the planning, and the control of ocular tumor protontherapy. It can be adapted to treatment planning to automatically detect eye and organs at risk position. It should be highlighted that all the image processing is fully automatic to allow the reproduction of results, this is a useful property to conduct a consistent clinical validation. The automatic localization of the organ at risk in a CT scan or an MRI by automatic software could be of great interest for radiotherapy in the future for comparison of one patient at different times, the comparison of different treatments centers, the possibility of pooling results of different treatments centers, the automatic generation of doses-volumes histograms, the comparison between different treatment planning for the same patient and the comparison between different patients at the same time. It will also be less time consuming

  10. A flexible 3D laser scanning system using a robotic arm

    Science.gov (United States)

    Fei, Zixuan; Zhou, Xiang; Gao, Xiaofei; Zhang, Guanliang

    2017-06-01

    In this paper, we present a flexible 3D scanning system based on a MEMS scanner mounted on an industrial arm with a turntable. This system has 7-degrees of freedom and is able to conduct a full field scan from any angle, suitable for scanning object with the complex shape. The existing non-contact 3D scanning system usually uses laser scanner that projects fixed stripe mounted on the Coordinate Measuring Machine (CMM) or industrial robot. These existing systems can't perform path planning without CAD models. The 3D scanning system presented in this paper can scan the object without CAD models, and we introduced this path planning method in the paper. We also propose a practical approach to calibrating the hand-in-eye system based on binocular stereo vision and analyzes the errors of the hand-eye calibration.

  11. Thermal fluctuation based study of aqueous deficient dry eyes by non-invasive thermal imaging.

    Science.gov (United States)

    Azharuddin, Mohammad; Bera, Sumanta Kr; Datta, Himadri; Dasgupta, Anjan Kr

    2014-03-01

    In this paper we have studied the thermal fluctuation patterns occurring at the ocular surface of the left and right eyes for aqueous deficient dry eye (ADDE) patients and control subjects by thermal imaging. We conducted our experiment on 42 patients (84 eyes) with aqueous deficient dry eyes and compared with 36 healthy volunteers (72 eyes) without any history of ocular surface disorder. Schirmer's test, Tear Break-up Time, tear Meniscus height and fluorescein staining tests were conducted. Ocular surface temperature measurement was done, using an FL-IR thermal camera and thermal fluctuation in left and right eyes was calculated and analyzed using MATLAB. The time series containing the sum of squares of the temperature fluctuation on the ocular surface were compared for aqueous deficient dry eye and control subjects. Significant statistical difference between the fluctuation patterns for control and ADDE was observed (p eyes are significantly correlated in controls but not in ADDE subjects. The possible origin of such correlation in control and lack of correlation in the ADDE subjects is discussed in the text. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Evidence of multisensory plasticity: Asymmetrical medial geniculate body in people with one eye

    Directory of Open Access Journals (Sweden)

    Stefania S. Moro

    2015-01-01

    Conclusions: volume asymmetry in the MGB in people with one eye may represent increased interactions between the left MGB and primary auditory cortex. This interaction could contribute to increased auditory and other left hemisphere-dominant processing, including language, as compensation for the loss of one half of visual inputs early in life. The positive correlation between MGB and LGN volume is not due to space constraints but rather indicates increased plasticity in both auditory and visual sensory systems following early eye enucleation.

  13. Measurement of radiation dose to the eye-lens with bilateral whole brain irradiation

    International Nuclear Information System (INIS)

    Kim, Ki Hwan; Park, Charn Il; Kang, Wee Saing; Choo, Dong Woon

    1985-01-01

    In 40 patients with metastatic brain tumor and acute lymphoblastic leukemia received whole brain irradiation, the dose delivered to the eye lens was measured using T.L.D. chips applied on the eyes as usual shield. The dose to the eye lens was expressed the relative dose to the mid brain dose. Radiotherapy was administrated using Co-60 teletherapy with bilateral whole brain irradiation. The results are as follows: 1. The dose to the right eye from its incipient field is 16.6% of tumor dose while the dose to the same eye from the opposite field is 41.2%. On left eye, 19.2% from incipient field while 39.2% from the opposite field. 2. Total received dose to right and left eyes is 28.9%, 29.8% of tumor dose respectively. 3. Comparing lens shield group with orbit shield group dose is 22.5%, 15.8% of tumor dose, respectively. 4. The dose delivered to the eye lens in ipsilateral side depends upon internal scattering, location of lead shield and penetrating dose of lead in itself. The dose in contralateral side depends upon divergency of radiation beam and patient's malposition. 5. The dose to the eye lens should be less than 10% of tumor dose with adequate shield, also not missing the chance of leptomeningeal recurrence because of overshielding.

  14. Yarbus, Eye Movements, and Vision

    Directory of Open Access Journals (Sweden)

    Benjamin W Tatler

    2010-04-01

    Full Text Available The impact of Yarbus's research on eye movements was enormous following the translation of his book Eye Movements and Vision into English in 1967. In stark contrast, the published material in English concerning his life is scant. We provide a brief biography of Yarbus and assess his impact on contemporary approaches to research on eye movements. While early interest in his work focused on his study of stabilised retinal images, more recently this has been replaced with interest in his work on the cognitive influences on scanning patterns. We extended his experiment on the effect of instructions on viewing a picture using a portrait of Yarbus rather than a painting. The results obtained broadly supported those found by Yarbus.

  15. [Firework-related eye trauma from 2005 to 2013].

    Science.gov (United States)

    Unterlauft, J D; Wiedemann, P; Meier, P

    2014-09-01

    Fireworks combusted during New Year's Eve festivities can cause different eye traumas which often need complex reconstructive surgery. It was our aim to systematically analyse these eye trauma cases which were treated at our clinic during the last eight years. Age, gender, side, trauma mechanism, treatment methods and outcome were analysed for all eye trauma cases caused by fireworks during the New Year's Eve celebrations from 2006 to 2013. For statistical analysis all trauma cases were divided into two groups of major and non-major eye trauma. The total number of patients treated was 122 (28 women, 94 men, mean age 26.2±13.0 years) with 137 traumatised eyes (77 right, 60 left). 24.6% of patients were ≤18 years of age. 76.2% were bystanders. 50 eyes from 46 patients (37.7%) suffered from major eye trauma. 26 patients (21.3%) were hospitalised. 8 eyes (5.8%) suffered from a penetrating injury or globe rupture and underwent primary reconstructive surgery. Further 16 eyes (11.7%) suffered from major eye trauma without open globe injury. In the aftermath 11 eyes (8.0%) went blind (visual acuityfireworks. However older patients suffer from major eye trauma more often. More education and prophylaxis of eye trauma caused by fireworks is desirable. Georg Thieme Verlag KG Stuttgart · New York.

  16. Neuroanatomical circuitry associated with exploratory eye movement in schizophrenia: a voxel-based morphometric study.

    Directory of Open Access Journals (Sweden)

    Linlin Qiu

    Full Text Available Schizophrenic patients present abnormalities in a variety of eye movement tasks. Exploratory eye movement (EEM dysfunction appears to be particularly specific to schizophrenia. However, the underlying mechanisms of EEM dysfunction in schizophrenia are not clearly understood. To assess the potential neuroanatomical substrates of EEM, we recorded EEM performance and conducted a voxel-based morphometric analysis of gray matter in 33 schizophrenic patients and 29 well matched healthy controls. In schizophrenic patients, decreased responsive search score (RSS and widespread gray matter density (GMD reductions were observed. Moreover, the RSS was positively correlated with GMD in distributed brain regions in schizophrenic patients. Furthermore, in schizophrenic patients, some brain regions with neuroanatomical deficits overlapped with some ones associated with RSS. These brain regions constituted an occipito-tempro-frontal circuitry involved in visual information processing and eye movement control, including the left calcarine cortex [Brodmann area (BA 17], the left cuneus (BA 18, the left superior occipital cortex (BA 18/19, the left superior frontal gyrus (BA 6, the left cerebellum, the right lingual cortex (BA 17/18, the right middle occipital cortex (BA19, the right inferior temporal cortex (BA 37, the right dorsolateral prefrontal cortex (BA 46 and bilateral precentral gyri (BA 6 extending to the frontal eye fields (FEF, BA 8. To our knowledge, we firstly reported empirical evidence that gray matter loss in the occipito-tempro-frontal neuroanatomical circuitry of visual processing system was associated with EEM performance in schizophrenia, which may be helpful for the future effort to reveal the underlying neural mechanisms for EEM disturbances in schizophrenia.

  17. Real Time Eye Detector with Cascaded Convolutional Neural Networks

    Directory of Open Access Journals (Sweden)

    Bin Li

    2018-01-01

    Full Text Available An accurate and efficient eye detector is essential for many computer vision applications. In this paper, we present an efficient method to evaluate the eye location from facial images. First, a group of candidate regions with regional extreme points is quickly proposed; then, a set of convolution neural networks (CNNs is adopted to determine the most likely eye region and classify the region as left or right eye; finally, the center of the eye is located with other CNNs. In the experiments using GI4E, BioID, and our datasets, our method attained a detection accuracy which is comparable to existing state-of-the-art methods; meanwhile, our method was faster and adaptable to variations of the images, including external light changes, facial occlusion, and changes in image modality.

  18. Influence of social presence on eye movements in visual search tasks.

    Science.gov (United States)

    Liu, Na; Yu, Ruifeng

    2017-12-01

    This study employed an eye-tracking technique to investigate the influence of social presence on eye movements in visual search tasks. A total of 20 male subjects performed visual search tasks in a 2 (target presence: present vs. absent) × 2 (task complexity: complex vs. simple) × 2 (social presence: alone vs. a human audience) within-subject experiment. Results indicated that the presence of an audience could evoke a social facilitation effect on response time in visual search tasks. Compared with working alone, the participants made fewer and shorter fixations, larger saccades and shorter scan path in simple search tasks and more and longer fixations, smaller saccades and longer scan path in complex search tasks when working with an audience. The saccade velocity and pupil diameter in the audience-present condition were larger than those in the working-alone condition. No significant change in target fixation number was observed between two social presence conditions. Practitioner Summary: This study employed an eye-tracking technique to examine the influence of social presence on eye movements in visual search tasks. Results clarified the variation mechanism and characteristics of oculomotor scanning induced by social presence in visual search.

  19. Eye Carduino: A Car Control System using Eye Movements

    Science.gov (United States)

    Kumar, Arjun; Nagaraj, Disha; Louzardo, Joel; Hegde, Rajeshwari

    2011-12-01

    Modern automotive systems are rapidly becoming highly of transportation, but can be a web integrated media centre. This paper explains the implementation of a vehicle control defined and characterized by embedded electronics and software. With new technologies, the vehicle industry is facing new opportunities and also new challenges. Electronics have improved the performance of vehicles and at the same time, new more complex applications are introduced. Examples of high level applications include adaptive cruise control and electronic stability programs (ESP). Further, a modern vehicle does not have to be merely a means using only eye movements. The EyeWriter's native hardware and software work to return the co-ordinates of where the user is looking. These co-ordinates are then used to control the car. A centre-point is defined on the screen. The higher on the screen the user's gaze is, the faster the car will accelerate. Braking is done by looking below centre. Steering is done by looking left and right on the screen.

  20. Eying the future: Eye movement in past and future thinking.

    Science.gov (United States)

    El Haj, Mohamad; Lenoble, Quentin

    2017-06-07

    We investigated eye movement during past and future thinking. Participants were invited to retrieve past events and to imagine future events while their scan path was recorded by an eye-tracker. Past thinking triggered more fixation (p thinking. Past and future thinking triggered a similar duration of fixations and saccades, as well as a similar amplitude of saccades. Interestingly, participants rated past thinking as more vivid than future thinking (p thinking seems to be accompanied by an increased number of fixations and saccades. Fixations and saccades in past thinking can be interpreted as an attempt by the visual system to find (through saccades) and activate (through fixations) stored memory representations. The same interpretation can be applied to future thinking as this ability requires activation of past experiences. However, future thinking triggers fewer fixations and saccades than past thinking: this may be due to its decreased demand on visual imagery, but could also be related to a potentially deleterious effect of eye movements on spatial imagery required for future thinking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Efficient feature for classification of eye movements using electrooculography signals

    Directory of Open Access Journals (Sweden)

    Phukpattaranont Pornchai

    2016-01-01

    Full Text Available Electrooculography (EOG signal is widely and successfully used to detect activities of human eye. The advantages of the EOG-based interface over other conventional interfaces have been presented in the last two decades; however, due to a lot of information in EOG signals, the extraction of useful features should be done before the classification task. In this study, an efficient feature extracted from two directional EOG signals: vertical and horizontal signals has been presented and evaluated. There are the maximum peak and valley amplitude values, the maximum peak and valley position values, and slope, which are derived from both vertical and horizontal signals. In the experiments, EOG signals obtained from five healthy subjects with ten directional eye movements were employed: up, down, right, left, up-right, up-left, down-right down-left clockwise and counterclockwise. The mean feature values and their standard deviations have been reported. The difference between the mean values of the proposed feature from different eye movements can be clearly seen. Using the scatter plot, the differences in features can be also clearly observed. Results show that classification accuracy can approach 100% with a simple distinction feature rule. The proposed features can be useful for various advanced human-computer interface applications in future researches.

  2. Simultaneous dual wavelength eye-tracked ultrahigh resolution retinal and choroidal optical coherence tomography

    DEFF Research Database (Denmark)

    Unterhuber, A.; Povaay, B.; Müller, André

    2013-01-01

    We demonstrate an optical coherence tomography device that simultaneously combines different novel ultrabroad bandwidth light sources centered in the 800 and 1060 nm regions, operating at 66 kHz depth scan rate, and a confocal laser scanning ophthalmoscope-based eye tracker to permit motion......-artifact-free, ultrahigh resolution and high contrast retinal and choroidal imaging. The two wavelengths of the device provide the complementary information needed for diagnosis of subtle retinal changes, while also increasing visibility of deeper-lying layers to image pathologies that include opaque media in the anterior...... eye segment or eyes with increased choroidal thickness....

  3. Significance of left ventricular volume measurement after heart transplantation using radionuclide techniques

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.; Boniaszczuk, J.

    1985-01-01

    Multigated equilibrium blood pool scanning using Technetium 99m labeled red blood cells was used to measure left ventricular volumes in three heterotopic and one orthotopic heart transplant recipient(s). Simultaneously, an endomyocardial biopsy was performed and the degree of acute rejection was assessed by a histological scoring system. The scores were correlated to changes in ejection fraction and heart rate. Technetium 99m scanning data were pooled according to the endomyocardial biopsy score: no rejection; mild rejection; moderate rejection, and severe rejection. In each group, the median of the left ventricular volume parameters was calculated and correlated with the endomyocardial biopsy score, using a non-parametric one-way analysis of variance. A decrease in stroke volume correlated best with the endomyocardial biopsy score during acute rejection. A decrease in end-diastolic left ventricular volumes did not correlate as well. Changes in the end-systolic left ventricular volumes were not statistically significant, but using a simple correlation between end-systolic left ventricular volumes and endomyocardial biopsy the correlation reached significance. Changes in left ventricular volumes measured by Technetium 99m scanning may be useful to confirm the presence or absence of acute rejection in patients with heart grafts

  4. Accessory hepatic lobe simulating a left hemidiaphragmatic tumor

    International Nuclear Information System (INIS)

    Kuroiwa, Toshiro; Hirata, Hitoshi; Iwashita, Akinori; Yasumori, Kotaro; Mogami, Hiroshi; Teraoka, Hiroaki

    1984-01-01

    A 72-year-old woman with a 20-year history of neuralgia was confirmed at surgery to have a tumor in the left hemidiaphragmatic region which was connected with the left lobe of the liver. Reassessment of radiological diagnosis after surgery revealed that hepatobiliary scintigraphy and computed tomography using left anterior oblique scanning are useful in differentiating the accessory hepatic lobe of the liver from a tumor and in confirming the diagnosis, respectively. (Namekawa, K.)

  5. Structural neural substrates of reading the mind in the eyes

    Directory of Open Access Journals (Sweden)

    Wataru eSato

    2016-04-01

    Full Text Available The ability to read the minds of others in their eyes plays an important role in human adaptation to social environments. Behavioral studies have resulted in the development of a test to measure this ability (Reading the Mind in the Eyes Test, revised version; Eyes Test, and have demonstrated that this ability is consistent over time. Although functional neuroimaging studies revealed brain activation while performing the Eyes Test, the structural neural substrates supporting consistent performance on the Eyes Test remain unclear. In this study we assessed the Eyes Test and analyzed structural magnetic resonance images using voxel-based morphometry in healthy participants. Test performance was positively associated with the gray matter volumes of the dorsomedial prefrontal cortex, inferior parietal lobule (temporoparietal junction, and precuneus in the left hemisphere. These results suggest that the fronto-temporoparietal network structures support the consistent ability to read the mind in the eyes.

  6. Primary orbital precursor T-cell lymphoblastic lymphoma

    DEFF Research Database (Denmark)

    Stenman, Lisa; Persson, Marta; Enlund, Fredrik

    2016-01-01

    Primary T-cell lymphoblastic lymphoma (T-LBL) in the eye region is very rare. The present study described a unique case of T-LBL involving the extraocular muscles. A 22-year-old male patient presented with a 3-week history of headache, reduced visual acuity and edema of the left eye. Clinical...... examination revealed left-sided exophthalmus, periorbital edema, chemosis, and reduced motility of the left eye. A magnetic resonance imaging scan revealed thickening of the left orbital muscles and a positron emission tomography-computed tomography scan also demonstrated activity in a subclavicular lymph....... There was no involvement of the bone marrow. Based on the clinical and histopathological findings, a diagnosis of T-LBL was made. There was no evidence of NOTCH1 mutation or rearrangements of the ETV6 and MLL genes and high-resolution array-based comparative genomic hybridization (arrayCGH) analysis revealed a normal...

  7. Scanning laser polarimetry in glaucomatous and nonglaucomatous Brazilian subjects Polarimetria de varredura a laser em grupos de brasileiros glaucomatosos e não glaucomatosos

    Directory of Open Access Journals (Sweden)

    Christiane Rolim de Moura

    2003-12-01

    Full Text Available PURPOSE: To compare the results of scanning laser polarimetry of the retinal nerve fiber layer obtained by using the GDx Scanning Laser System® in primary open angle glaucoma (POAG and nonglaucomatous Brazilian subjects over 40 years, also analyzing the differences between the data obtained from right and left eyes. METHODS: Forty-six POAG patients and 44 normal subjects were enrolled in this study. Retardation data were assessed by the GDx Scanning Laser System®. The medians of the parameters printed in the result were compared in these two groups, separately in the right and left eyes, using Mann-Whitney's test. Also the frequencies of outside normal parameters and quadrants of deviation from normal graph were compared in these two groups, using chi-square or Fisher's exact test. RESULTS: All parameters obtained by GDx differed in a statistically significant way between the two groups, except symmetry for left eyes. The frequency of inferior quadrant with pOBJETIVOS: Comparar os resultados da polarimetria de varredura a laser da camada de fibras nervosas obtidas por meio do GDx Scanning Laser System® em brasileiros portadores de glaucoma primário de ângulo aberto e indivíduos não glaucomatosos acima de 40 anos, analisando também as diferenças obtidas entre olhos direitos e esquerdos. MÉTODOS: Foram incluídos neste estudo 46 pacientes portadores de glaucoma primário de ângulo aberto e 44 pacientes normais. Os dados de retardo polarimétrico foram obtidos por meio do GDx Scanning Laser System®. As medianas dos parâmetros impressos no resultado foram comparadas nesses dois grupos, separadamente para olhos direitos e esquerdos, usando o teste de Mann-Whitney. A freqüência de parâmetros impressa como fora da normalidade e quadrantes estatisticamente alterados do gráfico "deviation from normal" foram comparados nesses dois grupos usando chi-quadrado e o teste exato de Fischer. RESULTADOS: Todos os parâmetros obtidos pelo GDx

  8. Differences of accommodative responses between two eyes under binocular viewing condition mediated by polarizing glasses

    Directory of Open Access Journals (Sweden)

    Rui-Qing Wang

    2016-04-01

    Full Text Available AIM:To study the differences of accommodative responses between the two eyes under 3 different polarized viewing conditions. METHODS:Fifteen volunteers with emmetrope were recruited into this study(aged 18~38, 6 males and 9 females. Three different viewing conditions were set up by using polarizing glasses and liquid crystal display:(1right eye could see the visual target on the screen, but left eye cannot see it;(2left eye could see the visual target on the screen, but right eye cannot see it;(3both eyes could see the target. Accommodative responses were measured by infrared auto-refractor when fixating at the target at 5, 2, 1, 0.5 and 0.33m under the above 3 viewing conditions. The differences of accommodative responses under different viewing conditions were compared by using variance analysis of repeated measuring and t test. RESULTS:Significant differences of accommodative responses between the two eyes were found under condition(1and(2at all the fixating distance. The accommodative responses in used eyes which can see the visual target were higher than in non-used eyes which cannot see the visual target(PP>0.05. CONCLUSION:Ciliary muscles in the used eyes were more relatively tonic than non-used eyes under binocular open viewing condition. The imbalance of accommodative responses between two eyes may be one of the risk factors resulting into the occurrence of myopia.

  9. [Trauma induced left maxillary sinus dislocation of eyeball--a case report].

    Science.gov (United States)

    Chen, Yu; Liu, Cuiping; Cui, Liping

    2013-01-01

    Patient male, 27 year old. Left facial and head trauma for 6 hours, due to motor vehicle accident. Patient state of mind was clear at arrival to hospital. Body temperature: 36C; Pulse: 80 Time/Minute; Breath: 20 Time/Minute; Blood pressure: 120/80 mm Hg. An irregular, horizontal laceration at arch of left eyebrow, approximately 8-10 cm. A laceration on left wing of nose skin, approximately 1 cm. A laceration also under lower eyelid skin of right eye, approximately 2 cm. Left blepharedema and enophthalmos. Orbital and nasal sinuses CT indications:contusion and laceration of the left frontal lobe of brain; fracture of the left orbital frontal, ethmoid, sphenoid bone, left nasal, maxillary sinus and zygoma with soft tissue contusion and laceration; the left eyeball and optic nerve sunk into the maxillary sinus (See figure 1). (1) Multiple orbital fractures; (2) Left maxillary sinus dislocation of eyeball; (3) The left frontal lobe contusion and laceration of brain.

  10. A case of acute psychosis induced by topical cyclopentolate eye drops in an elderly patient

    Directory of Open Access Journals (Sweden)

    Neha Rajappa

    2014-01-01

    Full Text Available A 75-year-old female patient was operated for cataract in her left eye. Cyclopentolate eye drops were started due to intraoperative handling of the iris. After the second dose of the eye drops, irrational behavior was observed. Psychiatrist′s opinion was taken and drug-induced psychosis was suspected. Thereafter, eye drops were withdrawn and the patient′s behaviour reverted to normal within 48 h.

  11. Evaluation of left ventricular function by cardiac CT

    International Nuclear Information System (INIS)

    Naito, Hiroaki; Kozuka, Takahiro

    1982-01-01

    Left ventricular function was evaluated by CT, which was compared with the data of left ventriculography for various cardiac diseases. The end diastolic volume of the left ventricle can be readily computed from CT, with a satisfactory correlation with that of left ventriculography (r = 0.95). The left ventricular ejection fraction, calculated from the areal ratio of the left ventricular lumen in end-diastolic imaging to that in end-sytolic imaging, also roughly reflects left ventricular contractile function, but shows correlation with left ventriculography by only r = 0.79. Although the cardiac output is not sensitive for functional evaluation, it can be directly calculated by means of dynamic scanning and shows a satisfactory correlation with the ear piece pigment dilution (r = 0.85). Evaluation of left ventricular function by CT shows a high precision in comparison with left ventriculography, but still lacks temporal resolving power. (Chiba, N.)

  12. New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation

    Science.gov (United States)

    Irsch, Kristina; Gramatikov, Boris I.; Wu, Yi-Kai; Guyton, David L.

    2014-06-01

    Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia's primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull's eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.

  13. New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation.

    Science.gov (United States)

    Irsch, Kristina; Gramatikov, Boris I; Wu, Yi-Kai; Guyton, David L

    2014-06-01

    Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia's primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull's eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.

  14. Complications related to a cosmetic eye-whitening procedure.

    Science.gov (United States)

    Vo, Rosalind C; Stafeeva, Ksenia; Aldave, Anthony J; Stulting, R Doyle; Moore, Quianta; Pflugfelder, Stephen C; Chungfat, Neil C; Holsclaw, Douglas S; Margolis, Todd P; Deng, Sophie X

    2014-11-01

    To report sight-threatening complications following extensive bulbar conjunctival resection and postoperative mitomycin C therapy for cosmetic eye-whitening in the United States. Retrospective noncomparative case series. Multicenter report of 9 patients referred for evaluation and management of complications following bilateral cosmetic eye whitening. Seventeen eyes of 9 patients underwent cosmetic eye-whitening performed between 2 and 48 months prior to referral to one of the centers. Sixteen of the 17 eyes had persistent conjunctival epithelial defects, with 10 eyes requiring amniotic membrane grafting to facilitate re-epithelialization. Four eyes of 2 patients developed limbal stem cell compromise confirmed with in vivo confocal laser scanning microscopy. One patient developed infectious scleritis and diplopia resulting from Tenon capsule scarring. Another patient developed scleral necrosis, secondary infectious scleritis, and infectious endophthalmitis. This patient subsequently developed noninfectious scleritis that required 3-drug-regimen immunosuppression. Severe adverse effects can occur after extensive cosmetic conjunctival resection followed by topical mitomycin C application. Patients and physicians should be aware of the potential sight-threatening complications associated with this eye-whitening procedure. Published by Elsevier Inc.

  15. Bilateral optic nerve head drusen with chorioretinal coloboma in the right eye

    Directory of Open Access Journals (Sweden)

    Ali Reza Dehghani

    2016-01-01

    Full Text Available Chorioretinal coloboma is a congenital defect of the eye caused by improper closure of the embryonic fissure. Optic nerve head drusen (ONHD are white calcareous deposits that are generally asymptomatic. We report a very rare association of both in a healthy patient with no any systemic syndrome. A 16-year-old man was referred to our clinic from suffering blurred vision. Best corrected visual acuity of the right eye was 6/10 and 10/10 in the left one. External ocular and slit lamp examination were normal. Dilated ophthalmoscopy showed marked swelling in both optic nerves and chorioretinal coloboma in the right eye inferiorly. Ultrasonography showed an echodense structure with acoustic shadowing in both eyes consistent with buried ONHD. Visual field testing showed normal field in the left eye and moderate superior field depression in the right eye corresponding to inferior coloboma in funduscopy. Results of general medical and neurologic, cardiologic, and other examinations were normal. To the best our knowledge combination of bilateral ONHD and unilateral chorioretinal coloboma in a healthy patient with no any systemic syndrome has not been published in the literature. We reported this very rare association and recommended examine eyes and other body organs. In such cases that coloboma is associated with ONHD, we should keep in mind Noonan syndrome. The diagnosis of Noonan syndrome is clinical and confirm by the consultant pediatricians and clinical geneticists.

  16. Effect of He-Ne laser beam on the ommatidia in Schistocerca Gregaria

    International Nuclear Information System (INIS)

    Abd El-Meguid, A.

    1996-01-01

    Exposing compound eye of Schistocerca Gregaria to He-Ne laser beam affected the micro-environment of the eye. The results indicated that the ionic content (Na, K and Ca) decreased and showed measurable percentage changes about 21.3, 45.9 and 14.9% (very high significant, VHS) in the right (R); and about 32.1, 71.4 and 9.4% (VHS) in the left (L) left (L) eyes. Respectively. As compared with control (Unexposed) eyes. Also protein content showed increase in concentrations about 70.2% (VHS) and 60.0% (Hs) in both right (R) and left (L) eyes. Respectively. While albumin content showed significant (S) decrease in concentrations about 34.6 and 26.3% in both right (R) and left (L) eyes. Respectively, as compared with the control ones. Histological sections as well as scanning electron micrographs showed that exposure of eyes to laser beam affected the structure of the eyes. 4 figs., 2 tabs

  17. Enhancing the early differential diagnosis of plateau iris and pupillary block using a-scan ultrasonography.

    Directory of Open Access Journals (Sweden)

    Yu-Yen Chen

    Full Text Available To distinguish the frequently misdiagnosed plateau iris eyes from pupillary block group and normal group, we compared the ocular biometrical parameters of them by A-scan ultrasongraphy.In total, we retrospectively reviewed general characteristics and ocular findings including ocular biometric measurements of 71 normal, 39 plateau iris, and 83 pupillary block eyes.The normal controls, plateau iris group and pupillary block group were significantly different in age, but not in gender. The anterior chamber depth tended to decrease and the lens thickness tended to increase from normal to plateau iris to pupillary block eyes. Compared to those of plateau iris group, the pupillary block group had significantly shallower anterior chamber depth (2.90mm vs. 2.33mm; p<0.001, thicker lens (4.77mm vs. 5.11mm; p<0.001, shorter axial length (23.16mm vs. 22.63mm; p<0.001, smaller relative lens position (2.28 vs. 2.16; p<0.001 and larger lens/axial length factor (2.06 vs. 2.26; p<0.001. However, when comparing plateau iris and normal eyes, only axial length and lens/axial length factor were significantly different (23.16 vs. 23.54; p<0.05 and 2.06 vs. 1.96; p<0.05.Measured by A-scan ultrasonography, the ocular biometrics of plateau iris were significantly different from those of pupillary block eyes. However, our A-scan ultrasongraphy generally found no significant biometric differences between plateau iris and normal eyes. These findings suggest that while A-scan ultrasonography might be used as a practical tool for differentiating plateau iris and papillary block eyes, a more meticulous gonioscopy and other assessments may be necessary to distinguish plateau iris from normal eyes.

  18. The Experimental Study of Safety and Efficacy in Using Bovis Calculus Pharmacopuncture Solution as Eye Drop

    Directory of Open Access Journals (Sweden)

    Hyeongsik Seo

    2009-09-01

    Full Text Available Objectives : This experimental study was performed to investigate the safety and efficacy of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. To identify the use of it as eye drop, the eye irritation test of rabbits and the antibacterial test of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans were performed. Methods : 1. The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60. After Bovis Calculus pharmacopuncture solution was administered in the left eye of the rabbits, eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 2. After administering Bovis Calculus pharmacopuncture solution on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans which cause Keratitis, MIC(Minimum Inhibition Concentration and the size of inhibition zone were measured. Anti-bacterial potency was also measured using the size of inhibition zone. Results : 1. After Bovis Calculus pharmacopuncture solution was administered in the left eye of the rabbits, it was found that none of nine rabbits have abnormal signs and weight changes. 2. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, no eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 3. There was no response to MIC on bacterial species (Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans after Bovis Calculus pharmacopuncture solution was medicated. Conclusions : The present study suggests that Bovis Calculus pharmacopuncture solution is a nontoxic and non-irritant medicine, which does not cause eye irritation in

  19. Can free-viewing perceptual asymmetries be explained by scanning, pre-motor or attentional biases?

    Science.gov (United States)

    Nicholls, Michael E R; Roberts, Georgina R

    2002-04-01

    Judgments of relative magnitude between the left and right sides of a stimulus are generally weighted toward the features contained on the left side. This leftward perceptual bias could be the result of, (a) left-to-right scanning biases, (b) pre-motor activation of the right hemisphere, or (c) a left hemispatial attentional bias. The relative merits of these explanations of perceptual asymmetry were investigated. In Experiment 1, English and Hebrew readers made luminance judgements for two left/right mirror-reversed luminance gradients (greyscales task). Despite different reading/scanning habits, both groups exhibited a leftward perceptual bias. English and Hebrew readers also performed a line bisection task. Scanning biases were controlled by asking participants to follow a marker as it moved left-to-right or right-to-left and then stop it as it reached the midpoint of the line. Despite controlling scanning, a leftward bias was observed in both groups. In Experiment 2, peripheral spatial cues were presented prior to the greyscales stimuli. English readers showed a reduction in the leftward bias for right-sided cues as compared to left-sided and neutral cues. Right-side cues presumably overcame a pre-existing leftward attentional bias. In both experiments, pre-motor activation was controlled using bimanual responses. Despite this control, a leftward bias was observed throughout the study. The data support the attentional bias account of leftward perceptual biases over the scanning and pre-motor activation accounts. Whether or not unilateral hemispheric activation provides an adequate account of this attentional bias is discussed.

  20. Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography

    Directory of Open Access Journals (Sweden)

    Nikoo Hamzeh

    2015-12-01

    Full Text Available AIM: To assess lens thickness measurements with anterior segment-optical coherence tomography (AS-OCT in comparison with A-scan ultrasonography (A-scan US. METHODS: There were 218 adult subjects (218 eyes aged 59.2±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity was graded using the Lens Opacities Classification System III (LOCS III. Lens thickness was measured by AS-OCT (Visante OCT, Carl Zeiss Meditec, Dublin, CA, USA. The highest quality image was selected for each eye and lens thickness was calculated using ImageJ software. Lens thickness was also measured by A-scan US. RESULTS: Interclass correlations showed a value of 99.7% for intra-visit measurements and 95.3% for inter-visit measurements. The mean lens thickness measured by AS-OCT was not significantly different from that of A-scan US (4.861±0.404 vs 4.866±0.351 mm, P=0.74. Lens thickness values obtained from the two instruments were highly correlated overall (Pearson correlation coefficient=0.81, P<0.001, and in all LOCS III specific subgroups except in grade 5 of nuclear opacity. Bland-Altman analysis revealed a 95% limit of agreement from -0.45 to 0.46 mm. Lens thickness difference between the two instruments became smaller as the lens thickness increased and AS-OCT yielded smaller values than A-scan US in thicker lens (β=-0.29, P<0.001 CONCLUSION: AS-OCT-derived lens thickness measurement is valid and comparable to the results obtained by A-scan US. It can be used as a reliable noncontact method for measuring lens thickness in adults with or without significant cataract.

  1. SU-F-I-32: Organ Doses from Pediatric Head CT Scan

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H; Liu, Q; Qiu, J; Zhuo, W [Institute of Radiation Medicine Fudan University, Shanghai (China); Majer, M; Knezevic, Z; Miljanic, S [Radiation Chemistry and Dosimetry Laboratory, Ruder Boskovic Institute, Zagreb (Croatia); Hrsak, H [Clinical Hospital Centre Zagreb, Zagreb (Croatia)

    2016-06-15

    Purpose: To evaluate the organ doses of pediatric patients who undergoing head CT scan using Monte Carlo (MC) simulation and compare it with measurements in anthropomorphic child phantom.. Methods: A ten years old children voxel phantom was developed from CT images, the voxel size of the phantom was 2mm*2mm*2mm. Organ doses from head CT scan were simulated using MCNPX software, 180 detectors were placed in the voxel phantom to tally the doses of the represented tissues or organs. When performing the simulation, 120 kVp and 88 mA were selected as the scan parameters. The scan range covered from the top of the head to the end of the chain, this protocol was used at CT simulator for radiotherapy. To validate the simulated results, organ doses were measured with radiophotoluminescence (RPL) detectors, placed in the 28 organs of the 10 years old CIRS ATOM phantom. Results: The organ doses results matched well between MC simulation and phantom measurements. The eyes dose was showed to be as expected the highest organ dose: 28.11 mGy by simulation and 27.34 mGy by measurement respectively. Doses for organs not included in the scan volume were much lower than those included in the scan volume, thymus doses were observed more than 10 mGy due the CT protocol for radiotherapy covered more body part than routine head CT scan. Conclusion: As the eyes are superficial organs, they may receive the highest radiation dose during the CT scan. Considering the relatively high radio sensitivity, using shielding material or organ based tube current modulation technique should be encouraged to reduce the eye radiation risks. Scan range was one of the most important factors that affects the organ doses during the CT scan. Use as short as reasonably possible scan range should be helpful to reduce the patient radiation dose. This work was supported by the National Natural Science Foundation of China(11475047)

  2. Acute Solar Retinopathy Imaged With Adaptive Optics, Optical Coherence Tomography Angiography, and En Face Optical Coherence Tomography.

    Science.gov (United States)

    Wu, Chris Y; Jansen, Michael E; Andrade, Jorge; Chui, Toco Y P; Do, Anna T; Rosen, Richard B; Deobhakta, Avnish

    2018-01-01

    Solar retinopathy is a rare form of retinal injury that occurs after direct sungazing. To enhance understanding of the structural changes that occur in solar retinopathy by obtaining high-resolution in vivo en face images. Case report of a young adult woman who presented to the New York Eye and Ear Infirmary with symptoms of acute solar retinopathy after viewing the solar eclipse on August 21, 2017. Results of comprehensive ophthalmic examination and images obtained by fundus photography, microperimetry, spectral-domain optical coherence tomography (OCT), adaptive optics scanning light ophthalmoscopy, OCT angiography, and en face OCT. The patient was examined after viewing the solar eclipse. Visual acuity was 20/20 OD and 20/25 OS. The patient was left-eye dominant. Spectral-domain OCT images were consistent with mild and severe acute solar retinopathy in the right and left eye, respectively. Microperimetry was normal in the right eye but showed paracentral decreased retinal sensitivity in the left eye with a central absolute scotoma. Adaptive optics images of the right eye showed a small region of nonwaveguiding photoreceptors, while images of the left eye showed a large area of abnormal and nonwaveguiding photoreceptors. Optical coherence tomography angiography images were normal in both eyes. En face OCT images of the right eye showed a small circular hyperreflective area, with central hyporeflectivity in the outer retina of the right eye. The left eye showed a hyperreflective lesion that intensified in area from inner to middle retina and became mostly hyporeflective in the outer retina. The shape of the lesion on adaptive optics and en face OCT images of the left eye corresponded to the shape of the scotoma drawn by the patient on Amsler grid. Acute solar retinopathy can present with foveal cone photoreceptor mosaic disturbances on adaptive optics scanning light ophthalmoscopy imaging. Corresponding reflectivity changes can be seen on en face OCT, especially

  3. Testing of the Safety and the Effectiveness of Using Samjeong Pharmacopuncture Solution as Eye drops

    Directory of Open Access Journals (Sweden)

    Seo Hyung-Sik

    2012-03-01

    Full Text Available Objective: This experimental study was designed to investigate the safety and the effectiveness of Samjeong pharmacopuncture solution (SPS manufactured by using a the lowtemperature extract on process. Methods: To identify the safety and the effectiveness of using SPS as eye drops, we performed applied eye irritation tests on rabbits and antibacterial tests for Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans. The eye irritation test was performed according to the toxicity testing regulation of the Korea Food & Drug Administration (2009. 8. 24, KFDA 2009-116. After SPS had been applied on the left eye of the rabbits, eye irritation in the cornea, iris and conjunctiva was observed on the 1st, 2nd, 3rd, 4th & 7th day. After SPS had been dropped on bacterial species that cause keratitis, the minimum inhibition concentration and the size of the inhibition zone were measured. The anti-bacterial potency was also measured by taking the size of inhibition zone. Results: After SPS had been administered on the left eye of the rabbits, none of nine rabbits were found to show abnormal signs or weight changes. After SPS had been administered on the left eye of the rabbits, no eye irritation in the cornea, iris and conjunctiva was observed on the 1st, 2nd, 3rd, 4th & 7th day. No specific response was detected in MIC for bacterial species Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans after SPS had been applied. Conclusions: This study suggests that SPS is a non-toxic and non-irritant medicine that does not cause any of eye irritation in rabbits, but it has no antibacterial effects on bacterial species that are well known to cause keratitis. These results suggest that more research is required on extracts from herbal medicines for treating keratitis.

  4. The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.

    Science.gov (United States)

    Krisanachinda, Anchali; Srimahachota, Suphot; Matsubara, Kosuke

    2017-06-01

    Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract.

  5. Application of a dummy eye shield for electron treatment planning

    International Nuclear Information System (INIS)

    Kang, Sei-Kwon; Park, Soah; Hwang, Taejin; Cheong, Kwang-Ho; Han, Taejin; Kim, Haeyoung; Lee, Me-Yeon; Kim, Kyoung Ju; Oh, Do Hoon; Bae, Hoonsik

    2013-01-01

    Metallic eye shields have been widely used for near-eye treatments to protect critical regions, but have never been incorporated into treatment plans because of the unwanted appearance of the metal artifacts on CT images. The purpose of this work was to test the use of an acrylic dummy eye shield as a substitute for a metallic eye shield during CT scans. An acrylic dummy shield of the same size as the tungsten eye shield was machined and CT scanned. The BEAMnrc and the DOSXYZnrc were used for the Monte Carlo (MC) simulation, with the appropriate material information and density for the aluminum cover, steel knob and tungsten body of the eye shield. The Pinnacle adopting the Hogstrom electron pencil-beam algorithm was used for the one-port 6-MeV beam plan after delineation and density override of the metallic parts. The results were confirmed with the metal oxide semiconductor field effect transistor (MOSFET) detectors and the Gafchromic EBT2 film measurements. For both the maximum eyelid dose over the shield and the maximum dose under the shield, the MC results agreed with the EBT2 measurements within 1.7%. For the Pinnacle plan, the maximum dose under the shield agreed with the MC within 0.3%; however, the eyelid dose differed by -19.3%. The adoption of the acrylic dummy eye shield was successful for the treatment plan. However, the Pinnacle pencil-beam algorithm was not sufficient to predict the eyelid dose on the tungsten shield, and more accurate algorithms like MC should be considered for a treatment plan. (author)

  6. An evaluation of the left-brain vs. right-brain hypothesis with resting state functional connectivity magnetic resonance imaging.

    Science.gov (United States)

    Nielsen, Jared A; Zielinski, Brandon A; Ferguson, Michael A; Lainhart, Janet E; Anderson, Jeffrey S

    2013-01-01

    Lateralized brain regions subserve functions such as language and visuospatial processing. It has been conjectured that individuals may be left-brain dominant or right-brain dominant based on personality and cognitive style, but neuroimaging data has not provided clear evidence whether such phenotypic differences in the strength of left-dominant or right-dominant networks exist. We evaluated whether strongly lateralized connections covaried within the same individuals. Data were analyzed from publicly available resting state scans for 1011 individuals between the ages of 7 and 29. For each subject, functional lateralization was measured for each pair of 7266 regions covering the gray matter at 5-mm resolution as a difference in correlation before and after inverting images across the midsagittal plane. The difference in gray matter density between homotopic coordinates was used as a regressor to reduce the effect of structural asymmetries on functional lateralization. Nine left- and 11 right-lateralized hubs were identified as peaks in the degree map from the graph of significantly lateralized connections. The left-lateralized hubs included regions from the default mode network (medial prefrontal cortex, posterior cingulate cortex, and temporoparietal junction) and language regions (e.g., Broca Area and Wernicke Area), whereas the right-lateralized hubs included regions from the attention control network (e.g., lateral intraparietal sulcus, anterior insula, area MT, and frontal eye fields). Left- and right-lateralized hubs formed two separable networks of mutually lateralized regions. Connections involving only left- or only right-lateralized hubs showed positive correlation across subjects, but only for connections sharing a node. Lateralization of brain connections appears to be a local rather than global property of brain networks, and our data are not consistent with a whole-brain phenotype of greater "left-brained" or greater "right-brained" network strength

  7. Defense Mechanisms, Psychosomatic Symptomatology, and Conjugate Lateral Eye Movements

    Science.gov (United States)

    Gur, Raquel E.; Gur, Ruben C.

    1975-01-01

    Subjects were classified into left movers, right movers, and bidirectionals according to the characteristic direction of their eye movements in response to questions. The three groups were compared on their preferential use of defense mechanisms and on the number of psychosomatic complaints. (Author)

  8. Anatomic relationship between left coronary artery and left atrium in patients undergoing atrial fibrillation ablation.

    Science.gov (United States)

    Anselmino, Matteo; Torri, Federica; Ferraris, Federico; Calò, Leonardo; Castagno, Davide; Gili, Sebastiano; Rovera, Chiara; Giustetto, Carla; Gaita, Fiorenzo

    2017-07-01

    Atrial fibrillation transcatheter ablation (TCA) is, within available atrial fibrillation rhythm control strategies, one of the most effective. To potentially improve ablation outcome in case of recurrent atrial fibrillation after a first procedure or in presence of structural myocardial disease, isolation of the pulmonary veins may be associated with extensive lesions within the left atrium. To avoid rare, but potentially life-threatening, complications, thorough knowledge and assessment of left atrium anatomy and its relation to structures in close proximity are, therefore, mandatory. Aim of the present study is to describe, by cardiac computed tomography, the anatomic relationship between aortic root, left coronary artery and left atrium in patients undergoing atrial fibrillation TCA. The cardiac computed tomography scan of 21 patients affected by atrial fibrillation was elaborated to segment left atrium, aortic root and left coronary artery from the surrounding structures and the following distances measured: left atrium and aortic root; left atrium roof and aortic root; left main coronary artery and left atrium; circumflex artery and left atrium appendage; and circumflex artery and mitral valve annulus. Above all, the median distance between left atrium and aortic root (1.9, 1.5-2.1 mm), and between circumflex artery and left atrium appendage ostium (3.0, 2.1-3.4 mm) were minimal (≤3 mm). None of measured distances significantly varied between patients presenting paroxysmal versus persistent atrial fibrillation. The anatomic relationship between left atrium and coronary arteries is extremely relevant when performing atrial fibrillation TCA by extensive lesions. Therefore, at least in the latter case, preablation imaging should be recommended to avoid rare, but potentially life-threatening, complications with the aim of an as well tolerated as possible procedure.

  9. Lateralization for visual processes: eye preference in Campbell's monkeys (Cercopithecus c. campbelli).

    Science.gov (United States)

    Chapelain, Amandine S; Blois-Heulin, Catherine

    2009-01-01

    Brain lateralization has been the matter of extensive research over the last centuries, but it remains an unsolved issue. While hand preferences have been extensively studied, very few studies have investigated laterality of eye use in non-human primates. We examined eye preference in 14 Campbell's monkeys (Cercopithecus c. campbelli). We assessed eye preference to look at a seed placed inside a tube using monocular vision. Eye use was recorded for 100 independent and non-rewarded trials per individual. All of the 14 monkeys showed very strong preferences in the choice of the eye used to look inside the tube (mean preference: 97.6%). Eight subjects preferred the right eye and six subjects preferred the left eye. The results are discussed in light of previous data on eye preference in primates, and compared to data on hand preference from these subjects. Our findings would support the hypothesis for an early emergence of lateralization for perceptual processes compared to manual motor functions.

  10. Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.

    Science.gov (United States)

    Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio

    2015-01-01

    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.

  11. Real-time eye lens dose monitoring during cerebral angiography procedures

    Energy Technology Data Exchange (ETDEWEB)

    Safari, M.J.; Wong, J.H.D.; Kadir, K.A.A.; Ng, K.H. [University of Malaya, Department of Biomedical Imaging, Faculty of Medicine, Kuala Lumpur (Malaysia); University of Malaya, University of Malaya Research Imaging Centre (UMRIC), Faculty of Medicine, Kuala Lumpur (Malaysia); Thorpe, N.K.; Cutajar, D.L.; Petasecca, M.; Lerch, M.L.F.; Rosenfeld, A.B. [University of Wollongong, Centre for Medical Radiation Physics (CMRP), Wollongong, NSW (Australia)

    2016-01-15

    To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures. Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures. The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R{sup 2}) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AK{sub L}: 0.93, AK{sub F}: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions. The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose. (orig.)

  12. Real-time eye lens dose monitoring during cerebral angiography procedures

    International Nuclear Information System (INIS)

    Safari, M.J.; Wong, J.H.D.; Kadir, K.A.A.; Ng, K.H.; Thorpe, N.K.; Cutajar, D.L.; Petasecca, M.; Lerch, M.L.F.; Rosenfeld, A.B.

    2016-01-01

    To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures. Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures. The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R 2 ) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AK L : 0.93, AK F : 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions. The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose. (orig.)

  13. Transient Peripapillary Retinoschisis in Glaucomatous Eyes

    Directory of Open Access Journals (Sweden)

    Josine van der Schoot

    2017-01-01

    Full Text Available Purpose. To investigate transient focal microcystic retinoschisis in glaucomatous eyes in images obtained with several imaging techniques used in daily glaucoma care. Methods. Images of 117 glaucoma patients and 91 healthy subjects participating in a large prospective follow-up study into glaucoma imaging were reviewed. Participants were measured with spectral domain optical coherence tomography (SD-OCT, scanning laser polarimetry (SLP, scanning laser tomography (SLT, and standard automated perimetry (SAP. The presence of a focal retinoschisis in SD-OCT was observed and correlated to SLP, SLT, and SAP measurements, both cross-sectionally and longitudinally. Results. Seven out of 117 glaucoma patients showed a transient, localised, peripapillary, heterogeneous microcystic schisis of the retinal nerve fiber layer (RNFL and sometimes other retinal layers as well in SD-OCT. None of the healthy eyes showed this phenomenon nor did any of the other imaging techniques display it as detailed and consistently as did the SD-OCT. SAP showed a temporarily decreased focal retinal sensitivity during the retinoschisis and we found no signs of glaucomatous progression related to the retinoschisis. Conclusions. Transient microcystic retinoschisis appears to be associated with glaucomatous wedge defects in the RNFL. It was best observed with SD-OCT and it was absent in healthy eyes. We found no evidence that the retinoschisis predicted glaucomatous progression.

  14. Eye movement during retrieval of emotional autobiographical memories.

    Science.gov (United States)

    El Haj, Mohamad; Nandrino, Jean-Louis; Antoine, Pascal; Boucart, Muriel; Lenoble, Quentin

    2017-03-01

    This study assessed whether specific eye movement patterns are observed during emotional autobiographical retrieval. Participants were asked to retrieve positive, negative and neutral memories while their scan path was recorded by an eye-tracker. Results showed that positive and negative emotional memories triggered more fixations and saccades but shorter fixation duration than neutral memories. No significant differences were observed between emotional and neutral memories for duration and amplitude of saccades. Positive and negative retrieval triggered similar eye movement (i.e., similar number of fixations and saccades, fixation duration, duration of saccades, and amplitude of saccades). Interestingly, the participants reported higher visual imagery for emotional memories than for neutral memories. The findings demonstrate similarities and differences in eye movement during retrieval of neutral and emotional memories. Eye movement during autobiographical retrieval seems to be triggered by the creation of visual mental images as the latter are indexed by autobiographical reconstruction. Copyright © 2016. Published by Elsevier B.V.

  15. [Total dream loss secondary to left temporo-occipital brain injury].

    Science.gov (United States)

    Poza, J J; Martí Massó, J F

    2006-04-01

    Recently the case of a woman who reported cessation of dreaming after a bilateral PCA stroke but without REM sleep loss has been reported, suggesting that deep bilateral occipital lobe damage including the right inferior lingual gyrus may represent the "minimal lesion extension" necessary for dream loss. We report the case of a 24-year-old man who ceased dreaming after a unilateral left temporo- occipital hematoma. The polysomnographic characteristics in rapid eyes movements (REM) sleep were otherwise normal. Our patient demonstrates that a unilateral left temporo-occipital injury could be sufficient for losing dreams.

  16. Automatic measurement of axial length of human eye using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Kiryu, Tohru

    2011-01-01

    The measurement of axial length and the evaluation of three dimensional (3D) form of an eye are essential to evaluate the mechanism of myopia progression. We propose a method of automatic measurement of axial length including adjustment of the pulse sequence of short-term scan which could suppress influence of eyeblink, using a magnetic resonance imaging (MRI) which acquires 3D images noninvasively. Acquiring T 2 -weighted images with 3.0 tesla MRI device and eight-channel phased-array head coil, we extracted left and right eye ball images, and then reconstructed 3D volume. The surface coordinates were calculated from 3D volume, fitting the ellipsoid model coordinates with the surface coordinates, and measured the axial length automatically. Measuring twenty one subjects, we compared the automatically measured values of axial length with the manually measured ones, then confirmed significant elongation in the axial length of myopia compared with that of emmetropia. Furthermore, there were no significant differences (P<0.05) between the means of automatic measurements and the manual ones. Accordingly, the automatic measurement process of axial length could be a tool for the elucidation of the mechanism of myopia progression, which would be suitable for evaluating the axial length easily and noninvasively. (author)

  17. The effects of simulating a realistic eye model on the eye dose of an adult male undergoing head computed tomography.

    Science.gov (United States)

    Akhlaghi, Parisa; Ebrahimi-Khankook, Atiyeh; Vejdani-Noghreiyan, Alireza

    2017-05-01

    In head computed tomography, radiation upon the eye lens (as an organ with high radiosensitivity) may cause lenticular opacity and cataracts. Therefore, quantitative dose assessment due to exposure of the eye lens and surrounding tissue is a matter of concern. For this purpose, an accurate eye model with realistic geometry and shape, in which different eye substructures are considered, is needed. To calculate the absorbed radiation dose of visual organs during head computed tomography scans, in this study, an existing sophisticated eye model was inserted at the related location in the head of the reference adult male phantom recommended by the International Commission on Radiological Protection (ICRP). Then absorbed doses and distributions of energy deposition in different parts of this eye model were calculated and compared with those based on a previous simple eye model. All calculations were done using the Monte Carlo code MCNP4C for tube voltages of 80, 100, 120 and 140 kVp. In spite of the similarity of total dose to the eye lens for both eye models, the dose delivered to the sensitive zone, which plays an important role in the induction of cataracts, was on average 3% higher for the sophisticated model as compared to the simple model. By increasing the tube voltage, differences between the total dose to the eye lens between the two phantoms decrease to 1%. Due to this level of agreement, use of the sophisticated eye model for patient dosimetry is not necessary. However, it still helps for an estimation of doses received by different eye substructures separately.

  18. Eye vergence responses during a visual memory task.

    Science.gov (United States)

    Solé Puig, Maria; Romeo, August; Cañete Crespillo, Jose; Supèr, Hans

    2017-02-08

    In a previous report it was shown that covertly attending visual stimuli produce small convergence of the eyes, and that visual stimuli can give rise to different modulations of the angle of eye vergence, depending on their power to capture attention. Working memory is highly dependent on attention. Therefore, in this study we assessed vergence responses in a memory task. Participants scanned a set of 8 or 12 images for 10 s, and thereafter were presented with a series of single images. One half were repeat images - that is, they belonged to the initial set - and the other half were novel images. Participants were asked to indicate whether or not the images were included in the initial image set. We observed that eyes converge during scanning the set of images and during the presentation of the single images. The convergence was stronger for remembered images compared with the vergence for nonremembered images. Modulation in pupil size did not correspond to behavioural responses. The correspondence between vergence and coding/retrieval processes of memory strengthen the idea of a role for vergence in attention processing of visual information.

  19. SOME ASPECTS OF SCANNING LASER OPHTHALMOSCOPY IN THE DIAGNOSTICS OF OPHTHALMOPATHOLOGY

    Directory of Open Access Journals (Sweden)

    S. A. Kochergin

    2017-01-01

    Full Text Available The exact diagnosis of the fundus pathology requires the most modern equipment use. This is mandatory for the selection of the most complete therapy and monitoring of ongoing treatment. At present, the method of scanning laser ophthalmoscopy is widely spread. However, for the earliest detection of the smallest pathological changes, data of the normal ocular fundus state using a scanning laser ophthalmoscope is necessary. Thus, the purpose of our research becomes relevant. Purpose: to give a characteristic of the fundus in patients without concomitant pathology with using various modes of a scanning laser ophthalmoscope. Patients and methods. 116 people (232 eyes at the age from 17 to 71 years (mean age 32.5±12 years were examined. The patients were divided into two groups. Group I: 81 patients (162 eyes with different ophthalmopathology. Group II: 35 people (70 eyes — practically healthy and did not have an anamnesis of consulting an ophthalmologist. Diagnosis of the patients’ fundus was performed using a scanning laser ophthalmoscopy with retro-mode imaging and autofluorescence registration. Results. After the conducted research features and regularities of the reflectivity distribution of laser beams from the fundus structures are revealed. Also a characteristic of various anatomical formations and zones of the fundus in the normal conditions is given when examined by a scanning laser ophthalmoscope. An algorithm for examining patients and analyzing the images was developed. Conclusion. The use of scanning laser ophthalmoscopy made possible to take a fresh look at the algorithms of diagnosing patients with fundus pathology. Understanding the normal conditions ofundus allowed an earlier detection of the smallest pathological changes in the retina. 

  20. Macular hemorrhage after roller coaster riding in a single-eyed patient with congenital glaucoma

    Directory of Open Access Journals (Sweden)

    Dilek Guven

    Full Text Available ABSTRACT A 21-year-old female presented with a 4-day history of decreased vision in her only functional eye (right eye, OD. She had a history of multiple ocular surgeries in both eyes because of congenital glaucoma and had lost light perception in her left eye several years prior. Ophthalmological examination revealed 0.15 Snellen visual acuity, and fundoscopy revealed nearly total cupping and pallor of the optic disc and multiple retinal hemorrhagic foci in the macula in OD. Lesions spontaneously resolved over a few months. Gravitational forces during a roller coaster ride may have caused this macular hemorrhage.

  1. Scanning laser ophthalmoscope design with adaptive optics

    OpenAIRE

    Laut, SP; Jones, SM; Olivier, SS; Werner, JS

    2005-01-01

    A design for a high-resolution scanning instrument is presented for in vivo imaging of the human eye at the cellular scale. This system combines adaptive optics technology with a scanning laser ophthalmoscope (SLO) to image structures with high lateral (∼2 μm) resolution. In this system, the ocular wavefront aberrations that reduce the resolution of conventional SLOs are detected by a Hartmann-Shack wavefront sensor, and compensated with two deformable mirrors in a closed-loop for dynamic cor...

  2. A study on the natural history of scanning behaviour in patients with visual field defects after stroke.

    Science.gov (United States)

    Loetscher, Tobias; Chen, Celia; Wignall, Sophie; Bulling, Andreas; Hoppe, Sabrina; Churches, Owen; Thomas, Nicole A; Nicholls, Michael E R; Lee, Andrew

    2015-04-24

    A visual field defect (VFD) is a common consequence of stroke with a detrimental effect upon the survivors' functional ability and quality of life. The identification of effective treatments for VFD is a key priority relating to life post-stroke. Understanding the natural evolution of scanning compensation over time may have important ramifications for the development of efficacious therapies. The study aims to unravel the natural history of visual scanning behaviour in patients with VFD. The assessment of scanning patterns in the acute to chronic stages of stroke will reveal who does and does not learn to compensate for vision loss. Eye-tracking glasses are used to delineate eye movements in a cohort of 100 stroke patients immediately after stroke, and additionally at 6 and 12 months post-stroke. The longitudinal study will assess eye movements in static (sitting) and dynamic (walking) conditions. The primary outcome constitutes the change of lateral eye movements from the acute to chronic stages of stroke. Secondary outcomes include changes of lateral eye movements over time as a function of subgroup characteristics, such as side of VFD, stroke location, stroke severity and cognitive functioning. The longitudinal comparison of patients who do and do not learn compensatory scanning techniques may reveal important prognostic markers of natural recovery. Importantly, it may also help to determine the most effective treatment window for visual rehabilitation.

  3. Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.

    Science.gov (United States)

    Özcura, Fatih; Aktaş, Serdar; Sağdık, Hacı Murat; Tetikoğlu, Mehmet

    2016-10-01

    The purpose of the study was to compare the accuracy of various biometric formulas for predicting postoperative refraction determined using applanation A-scan ultrasound. This retrospective comparative study included 485 eyes that underwent uneventful phacoemulsification with intraocular lens (IOL) implantation. Applanation A-scan ultrasound biometry and postoperative manifest refraction were obtained in all eyes. Biometric data were entered into each of the five IOL power calculation formulas: SRK-II, SRK/T, Holladay I, Hoffer Q, and Binkhorst II. All eyes were divided into three groups according to axial length: short (≤22.0 mm), average (22.0-25.0 mm), and long (≥25.0 mm) eyes. The postoperative spherical equivalent was calculated and compared with the predicted refractive error using each biometric formula. The results showed that all formulas had significantly lower mean absolute error (MAE) in comparison with Binkhorst II formula (P < 0.01). The lowest MAE was obtained with the SRK-II for average (0.49 ± 0.40 D) and short (0.67 ± 0.54 D) eyes and the SRK/T for long (0.61 ± 0.50 D) eyes. The highest postoperative hyperopic shift was seen with the SRK-II for average (46.8 %), short (28.1 %), and long (48.4 %) eyes. The highest postoperative myopic shift was seen with the Holladay I for average (66.4 %) and long (71.0 %) eyes and the SRK/T for short eyes (80.6 %). In conclusion, the SRK-II formula produced the lowest MAE in average and short eyes and the SRK/T formula produced the lowest MAE in long eyes. The SRK-II has the highest postoperative hyperopic shift in all eyes. The highest postoperative myopic shift is with the Holladay I for average and long eyes and SRK/T for short eyes.

  4. Hypodense regions (holes) in the retinal nerve fiber layer in frequency-domain OCT scans of glaucoma patients and suspects.

    Science.gov (United States)

    Xin, Daiyan; Talamini, Christine L; Raza, Ali S; de Moraes, Carlos Gustavo V; Greenstein, Vivienne C; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2011-09-09

    To better understand hypodense regions (holes) that appear in the retinal nerve fiber layer (RNFL) of frequency-domain optical coherence tomography (fdOCT) scans of patients with glaucoma and glaucoma suspects. Peripapillary circle (1.7-mm radius) and cube optic disc fdOCT scans were obtained on 208 eyes from 110 patients (57.4 ± 13.2 years) with glaucomatous optic neuropathy (GON) and 45 eyes of 45 controls (48.0 ± 12.6 years) with normal results of fundus examination. Holes in the RNFL were identified independently by two observers on the circle scans. Holes were found in 33 (16%) eyes of 28 (25%) patients; they were not found in any of the control eyes. Twenty-four eyes had more than one hole. Although some holes were relatively large, others were small. In general, the holes were located adjacent to blood vessels; only three eyes had isolated holes that were not adjacent to a vessel. The holes tended to be in the regions that are thickest in healthy controls and were associated with arcuate defects in patients. Holes were not seen in the center of the temporal disc region. They were more common in the superior (25 eyes) than in the inferior (15 eyes) disc. Of the 30 eyes with holes with reliable visual fields, seven were glaucoma suspect eyes with normal visual fields. The holes in the RNFL seen in patients with GON were probably due to a local loss of RNFL fibers and can occur in the eyes of glaucoma suspects with normal visual fields.

  5. A negative bone scan leads to an unusual diagnosis

    International Nuclear Information System (INIS)

    O'Brien, L.

    1998-01-01

    Full text: A bone scan looking for osteomyelitis or a more sinister pathology was performed on a 7-year-old boy with Von Willebrand''s disease. He presented with symptoms of pain in the left groin and a lump, although there had been no history of direct trauma, and an X-ray report stating that there was an irregular ill-defined area of bony destruction seen in the lower aspect of the left ischium. Blood pool images of the pelvis were acquired soon after an injection of MDP and three hours later a whole body bone scan was done. Results of the bone scan showed that the radiolucent lesion in the left ilium seen on the plain radiographs was not metabolically active on the technetium MDP study. Features compatible with a response to an intraosseous or sub-periosteal haematoma were seen when reviewing the original X-rays and, as there was a spontaneous resolution of the patient''s symptoms, this was considered to be the diagnosis. This study shows that a negative bone scan, which rules out an active bone lesion, is of value in making a diagnosis when used in conjunction with X-rays and a knowledge of the patient''s history

  6. Patterning of a compound eye on an extinct dipteran wing

    OpenAIRE

    Dinwiddie, April; Rachootin, Stan

    2010-01-01

    We have discovered unexpected similarities between a novel and characteristic wing organ in an extinct biting midge from Baltic amber, Eohelea petrunkevitchi, and the surface of a dipteran's compound eye. Scanning electron microscope images now reveal vestigial mechanoreceptors between the facets of the organ. We interpret Eohelea's wing organ as the blending of these two developmental systems: the formation and patterning of the cuticle in the eye and of the wing.

  7. Influence of heart rhythm, breathing and arm position during computed tomography scanning on the registration accuracy of electro anatomical map (EAM) images, left atrium three-dimensional computed tomography angiography images, and fluoroscopy time during ablation to treat atrial fibrillation

    International Nuclear Information System (INIS)

    Chono, Taiki; Shimoshige, Shinya; Yoshikawa, Kenta; Mizonobe, Kazuhusa; Ogura, Keishi

    2013-01-01

    In CARTOMERGE for treatment of atrial fibrillation (AF) by ablation, by integrating electro anatomical map (EAM) and left atrium three-dimensional computed tomography angiography (3D-CTA) images, identification of the ablation points is simplified and the procedure can be made carried out more rapidly. However, the influence that heart rhythm, breathing and arm position during CT scanning have on registration accuracy and fluoroscopy time is not clear. To clarify the influence on registration accuracy and fluoroscopy time of heart rhythm, breathing and arm position during CT scanning. The patients were CT-scanned during both sinus rhythm (SR) and AF in each study subject. We evaluated the registration accuracy of images reconstructed between the cardiac cycle and assessed the registration accuracy and fluoroscopy time of images obtained during inspiratory breath-hold, expiratory breath-hold and up and down position of the arm. Although the registration accuracy of the EAM image and left atrium 3D-CTA image showed a significant difference during SR, no significant difference was seen during AF. Expiratory breath-hold and down position of the arm resulted in the highest registration accuracy and the shortest fluoroscopy time. However, arm position had no significant effect on registration accuracy. Heart rhythm and breathing during CT scanning have a significant effect on the registration accuracy of EAM images, left atrium 3D-CTA images, and fluoroscopy time. (author)

  8. Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry.

    Science.gov (United States)

    Kim, Sun Woong; Byun, Yeo Jue; Kim, Eung Kweon; Kim, Tae-im

    2007-11-01

    To compare central corneal thickness measurements obtained in unoperated eyes and eyes after myopic photorefractive keratectomy (PRK) using a rotating Scheimpflug camera (Pentacam), a scanning slit corneal topography system (Orbscan II), and ultrasonic pachymetry. Corneal thickness was measured using Pentacam, Orbscan II, and ultrasonic pachymetry in 25 unoperated eyes (unoperated group), 24 eyes 1 to 3 months after myopic PRK (early postoperative PRK group), and 21 eyes 4 months or more after myopic PRK (late postoperative PRK group). In the unoperated group, corneal thickness measurements were similar for all three methods (P=.125). In the early postoperative PRK group, Orbscan measurements were thinner than Pentacam and ultrasonic measurements by a mean of 69.4 microm and 63.4 microm (PPRK group, Orbscan measurements were thinner than Pentacam measurements by a mean of 36.0 microm (P=.017). Pentacam and ultrasonic pachymetry measurements were similar for all three groups with a mean difference of approximately 10 microm. Following myopic PRK, Pentacam was comparable to ultrasonic pachymetry in measuring corneal thickness, whereas Orbscan measurements were thinner.

  9. The highly myopic eye--oculometric considerations

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Goldschmidt, Ernst

    2012-01-01

    (n=39) in 1962. Clinical follow-up studies were conducted in 1976, 1986, 1995 and 2002, with A-scan ultrasound oculometry (Kretztechnik 7000, immersion method; and Sonometrics 400, contact method) as a regular part of the schedule. For comparison, IOL Master evaluations were added in 2002...... by Francois and Goes, not all long eyes have flat corneas. In our high myopia series, a significant subgroup could thus be discerned who had peaked corneas, which led to mathematically slight reduction of the usual positive correlation between axial length and curvature radius in the ametropia population......; and (d) we found positive correlation between myopia increase in adult age and axial elongation, stressing that, in contrast to other outgrown body structures, the adult eye globes may still expand in size. This feature seems to be found not only in the eyes with posterior staphyloma, but also in myopic...

  10. The Interaction of Eye-Voice Span with Syntactic Chunking and Predictability in Right- and Left-Embedded Sentences.

    Science.gov (United States)

    Balajthy, Ernest P., Jr.

    Sixty tenth graders participated in this study of relationships between eye/voice span, phrase and clause boundaries, reading ability, and sentence structure. Results indicated that sentences apparently are "chunked" into surface constituents during processing. Better tenth grade readers had longer eye/voice spans than did poorer readers and…

  11. Unilateral Eye Blinking Arising From the Ictal Ipsilateral Occipital Area.

    Science.gov (United States)

    Falsaperla, Raffaele; Perciavalle, Valentina; Pavone, Piero; Praticò, Andrea Domenico; Elia, Maurizio; Ruggieri, Martino; Caraballo, Roberto; Striano, Pasquale

    2016-07-01

    We report on an 18-month-old boy with unilateral left eye blinking as a single ictal manifestation without facial twitching. The clinical onset of this phenomenon was first recorded (as an occasional event) at age 3 months, and it was overlooked. By age 6 months, the child's blinking increased to almost daily occurrence in clusters: during blinking the infant showed intact awareness and occasional jerks in the upper limbs and right leg. A video-electroencephalography (video-EEG) documented clinical correlation with a focal pattern arising from the left occipital region, and brain magnetic resonance imaging (MRI) revealed severe brain damage, consisting in poroencephalic hollows and increased spaces in the convexities involving a large area of the left cerebral hemisphere. The boy was prescribed sodium valproate (30 mg/kg/d), resulting in drastic reduction of his clinical seizures. Follow-up to his current age documented good general status, with persistent partial right hemilateral seizures. The blinking progressively disappeared, and is no longer recorded. The pathogenic hypotheses of the unilateral ictal blinking include involvement of the ipsilateral cerebral hemisphere and/or the cerebellar pathways. Review of previous reports of unilateral eye blinking, arising from the ictal ipsilateral brain, revealed that different damaged regions may give rise to blinking ictal phenomena, likely via the trigeminal fibres innervating the subdural intracranial structures and the pial vessels in the ipsilateral affected brain. The eye blinking in the present child represents a further example of an ictal phenomenon, which is predictive of the damaged brain region. © EEG and Clinical Neuroscience Society (ECNS) 2014.

  12. Pilot Study: The Role of the Hemispheric Lateralization in Mental Disorders by Use of the Limb (Eye, Hand, Foot) Dominance.

    Science.gov (United States)

    Goodarzi, Naser; Dabbaghi, Parviz; Valipour, Habib; Vafadari, Behnam

    2015-04-01

    Based on the previous studies, we know that the hemispheric lateralization defects, increase the probability of psychological disorders. We also know that dominant limb is controlled by dominant hemisphere and limb preference is used as an indicator for hemisphere dominance. In this study we attempted to explore the hemispheric dominance by the use of three limbs (hand, foot and eye). We performed this survey on two samples, psychiatric patients compared with normal population. For this purpose, knowing that the organ dominance is stabilized in adolescence, and age has no effect on the people above 15, we used 48 high school girls and 65 boys as the final samples of normal population. The patient group included 57 male and 26 female who were chronic psychiatric patients. The result shows that left-eye dominance is more in patients than the normal group (P=0.000) but the handedness and footedness differences are not significance. In psychotic, bipolar and depressive disorders, eye dominance had significant difference (P=0.018). But this is not true about hand and foot dominance. Our findings proved that generally in psychiatric patients, left-eye dominance is more common, left-eye dominance is also more in psychotic and depressive disorders. It is less common in bipolar disorders.

  13. Tutorial on Biostatistics: Linear Regression Analysis of Continuous Correlated Eye Data.

    Science.gov (United States)

    Ying, Gui-Shuang; Maguire, Maureen G; Glynn, Robert; Rosner, Bernard

    2017-04-01

    To describe and demonstrate appropriate linear regression methods for analyzing correlated continuous eye data. We describe several approaches to regression analysis involving both eyes, including mixed effects and marginal models under various covariance structures to account for inter-eye correlation. We demonstrate, with SAS statistical software, applications in a study comparing baseline refractive error between one eye with choroidal neovascularization (CNV) and the unaffected fellow eye, and in a study determining factors associated with visual field in the elderly. When refractive error from both eyes were analyzed with standard linear regression without accounting for inter-eye correlation (adjusting for demographic and ocular covariates), the difference between eyes with CNV and fellow eyes was 0.15 diopters (D; 95% confidence interval, CI -0.03 to 0.32D, p = 0.10). Using a mixed effects model or a marginal model, the estimated difference was the same but with narrower 95% CI (0.01 to 0.28D, p = 0.03). Standard regression for visual field data from both eyes provided biased estimates of standard error (generally underestimated) and smaller p-values, while analysis of the worse eye provided larger p-values than mixed effects models and marginal models. In research involving both eyes, ignoring inter-eye correlation can lead to invalid inferences. Analysis using only right or left eyes is valid, but decreases power. Worse-eye analysis can provide less power and biased estimates of effect. Mixed effects or marginal models using the eye as the unit of analysis should be used to appropriately account for inter-eye correlation and maximize power and precision.

  14. Atypical Saccadic Scanning in Autistic Spectrum Disorder

    Science.gov (United States)

    Benson, Valerie; Piper, Jenna; Fletcher-Watson, Sue

    2009-01-01

    Saccadic scanning was examined for typically developing (TD) adults and those with autistic spectrum disorder (ASD) during inspection of the "Repin" picture (Yarbus, A. (1967). "Eye movements and vision". New York: Plenum) under two different viewing instructions: (A) material instructions ("Estimate the material circumstances of the family"); and…

  15. Increased opacity of left pericardiac area on chest radiograph : correlation with CT findings and its frequency

    International Nuclear Information System (INIS)

    Lee, Seung Ik; Kim, Jeung Sook; Kwak, Jin Young; Ryu, Chang Woo; Yoon, Sam Hyun

    1998-01-01

    The purpose of this study was to evaluate the incidence of extrapericardial fat in the left cardiac border, and with regard to left extrapericardial fat, to correlate chest radiographs with CT scans. This study involved 132 consecutive patients who underwent chest PA and lateral radiographs, and chest CT scans. According to the results of chest PA radiograph, patients were divided into three groups: those with a clear left cardiac border; those with an indistinct left cardiac border; and those with an indistinct left cardiac border with increased density; cardiophrenic angle, as seen on lateral radiograph, the presence of increased density in the anterior cardiophrenic angle, as seen on lateral radiographs was evaluated. On the basis of the results of CT scanning, patients were classified into four groups according to the amount of left extrapericardial fat : negative, minimum, moderate, and maximum. Left extrapericardial fat, as seen on CT, was correlated with the conspicuity of left cardiac border seen on PA radiograph and the presence of increased density in the anterior cardiophrenic angle, as seen on lateral radiograph. The conspicuousness of the left cardiac border, as seen on PA chest radiograph, correlated with the presence of left extrapericardial fat, as seen on CT, and was related to the amount of left extrapericardial fat. Increased density of the anterior cardiophrenic angle, as seen on lateral radiographs, correlated with the presence of left extrapericardial fat on CT, but the absence of increased density on lateral radiograph corresponds to the absence or a minimal amount of left extrapericardial fat, as seen on CT. (author). 8 refs., 4 tabs., 3 figs

  16. The Usefulness of Bone Scan in Electric Burns

    International Nuclear Information System (INIS)

    Kim, Tae Hyung; So, Yong Seon; Kweon, Ki Hyeon; Han, Sang Woong; Kim, Seok Hwan; Kim, Jong Soon; Han, Seung Soo

    1996-01-01

    Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as determining to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites and bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, scrum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  17. The Usefulness of Bone Scan in Electric Burns

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; So, Yong Seon; Kweon, Ki Hyeon; Han, Sang Woong; Kim, Seok Hwan; Kim, Jong Soon; Han, Seung Soo [Hanil Hospital, Seoul (Korea, Republic of)

    1996-03-15

    Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as determining to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites and bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, scrum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  18. Measurement of eye aberrations in a speckle field

    International Nuclear Information System (INIS)

    Larichev, A V; Ivanov, P V; Iroshnikov, N G; Shmalgauzen, V I

    2001-01-01

    The influence of speckles on the performance of a Shark-Hartmann wavefront sensor is investigated in the eye aberration studies. The dependence of the phase distortion measurement error on the characteristic speckle size is determined experimentally. Scanning of the reference source was used to suppress the speckle structure of the laser beam scattered by the retina. The technique developed by us made it possible to study the time dependence of the human eye aberrations with a resolution of 30 ms. (laser applications and other topics in quantum electronics)

  19. Impaired exploratory eye movements in children with Asperger's syndrome.

    Science.gov (United States)

    Ohya, Takashi; Morita, Kiichiro; Yamashita, Yushiro; Egami, Chiyomi; Ishii, Youhei; Nagamitsu, Shinichiro; Matsuishi, Toyojiro

    2014-03-01

    Previous eye-tracking studies using an eye mark recorder have reported that disturbances in exploratory eye movements in adult schizophrenic patients are associated with social functioning. The current study sought to determine whether exploratory eye-movement disturbances are present in children with Asperger's syndrome (AS) compared with typically developing (TD) children. MATERIALS/PARTICIPANTS: The participants were 23 children with AS and 23 age-matched TD children. We measured exploratory eye movements using an EMR-8B eye mark recorder and an exploratory eye movement-measuring device. Eye movements were recorded while participants freely observed a geometric figure (free viewing task), and while they complied with the instructions of an experimenter (repeat-comparison task). We assessed eye fixation points (EFPs) and total eye scanning length (TESL) in all tasks, and measured the responsive search score (RSS) in the repeat-comparison task. In the free viewing task, children with AS exhibited significantly shorter TESL compared with TD children. In the repeat-comparison task, children with AS exhibited significantly lower RSS. Autism Spectrum Screening Questionnaire scores were negatively correlated with both EFP and TESL, but not RSS. The current results revealed that children with AS exhibited dysfunction in exploratory eye movements. Thus, assessing exploratory eye movements in a repeat-comparison task may be useful for detecting social impairment among children with AS. Copyright © 2013 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  20. Relating lateralization of eye use to body motion in the avoidance behavior of the chameleon (Chamaeleo chameleon).

    Science.gov (United States)

    Lustig, Avichai; Ketter-Katz, Hadas; Katzir, Gadi

    2013-01-01

    Lateralization is mostly analyzed for single traits, but seldom for two or more traits while performing a given task (e.g. object manipulation). We examined lateralization in eye use and in body motion that co-occur during avoidance behaviour of the common chameleon, Chamaeleo chameleon. A chameleon facing a moving threat smoothly repositions its body on the side of its perch distal to the threat, to minimize its visual exposure. We previously demonstrated that during the response (i) eye use and body motion were, each, lateralized at the tested group level (N = 26), (ii) in body motion, we observed two similar-sized sub-groups, one exhibiting a greater reduction in body exposure to threat approaching from the left and one--to threat approaching from the right (left- and right-biased subgroups), (iii) the left-biased sub-group exhibited weak lateralization of body exposure under binocular threat viewing and none under monocular viewing while the right-biased sub-group exhibited strong lateralization under both monocular and binocular threat viewing. In avoidance, how is eye use related to body motion at the entire group and at the sub-group levels? We demonstrate that (i) in the left-biased sub-group, eye use is not lateralized, (ii) in the right-biased sub-group, eye use is lateralized under binocular, but not monocular viewing of the threat, (iii) the dominance of the right-biased sub-group determines the lateralization of the entire group tested. We conclude that in chameleons, patterns of lateralization of visual function and body motion are inter-related at a subtle level. Presently, the patterns cannot be compared with humans' or related to the unique visual system of chameleons, with highly independent eye movements, complete optic nerve decussation and relatively few inter-hemispheric commissures. We present a model to explain the possible inter-hemispheric differences in dominance in chameleons' visual control of body motion during avoidance.

  1. Relating lateralization of eye use to body motion in the avoidance behavior of the chameleon (Chamaeleo chameleon.

    Directory of Open Access Journals (Sweden)

    Avichai Lustig

    Full Text Available Lateralization is mostly analyzed for single traits, but seldom for two or more traits while performing a given task (e.g. object manipulation. We examined lateralization in eye use and in body motion that co-occur during avoidance behaviour of the common chameleon, Chamaeleo chameleon. A chameleon facing a moving threat smoothly repositions its body on the side of its perch distal to the threat, to minimize its visual exposure. We previously demonstrated that during the response (i eye use and body motion were, each, lateralized at the tested group level (N = 26, (ii in body motion, we observed two similar-sized sub-groups, one exhibiting a greater reduction in body exposure to threat approaching from the left and one--to threat approaching from the right (left- and right-biased subgroups, (iii the left-biased sub-group exhibited weak lateralization of body exposure under binocular threat viewing and none under monocular viewing while the right-biased sub-group exhibited strong lateralization under both monocular and binocular threat viewing. In avoidance, how is eye use related to body motion at the entire group and at the sub-group levels? We demonstrate that (i in the left-biased sub-group, eye use is not lateralized, (ii in the right-biased sub-group, eye use is lateralized under binocular, but not monocular viewing of the threat, (iii the dominance of the right-biased sub-group determines the lateralization of the entire group tested. We conclude that in chameleons, patterns of lateralization of visual function and body motion are inter-related at a subtle level. Presently, the patterns cannot be compared with humans' or related to the unique visual system of chameleons, with highly independent eye movements, complete optic nerve decussation and relatively few inter-hemispheric commissures. We present a model to explain the possible inter-hemispheric differences in dominance in chameleons' visual control of body motion during avoidance.

  2. Hawk eyes I: diurnal raptors differ in visual fields and degree of eye movement.

    Directory of Open Access Journals (Sweden)

    Colleen T O'Rourke

    Full Text Available BACKGROUND: Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. METHODOLOGY/PRINCIPAL FINDINGS: We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33° and wide blind areas (∼82°, but intermediate degree of eye movement (∼5°, which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°, small blind areas (∼60°, and high degree of eye movement (∼8°, which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1° may help stabilize the image when hovering above prey before an attack. CONCLUSIONS: We conclude that: (a there are between-species differences in visual field configuration in these diurnal raptors; (b these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats; (c variations in the degree of eye movement between species appear associated with foraging strategies; and (d the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence

  3. Hawk eyes I: diurnal raptors differ in visual fields and degree of eye movement.

    Science.gov (United States)

    O'Rourke, Colleen T; Hall, Margaret I; Pitlik, Todd; Fernández-Juricic, Esteban

    2010-09-22

    Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33°) and wide blind areas (∼82°), but intermediate degree of eye movement (∼5°), which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°), small blind areas (∼60°), and high degree of eye movement (∼8°), which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1°) may help stabilize the image when hovering above prey before an attack. We conclude that: (a) there are between-species differences in visual field configuration in these diurnal raptors; (b) these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats); (c) variations in the degree of eye movement between species appear associated with foraging strategies; and (d) the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence behavioral strategies to visually search for and track prey while

  4. The impact of x-ray tube configuration on the eye lens and extremity doses received by cardiologists in electrophysiology room

    International Nuclear Information System (INIS)

    Domienik, J; Zmyślony, M; Bissinger, A

    2014-01-01

    The aim of the study was to analyse the influence of the x-ray tube configuration on the radiation doses to eye lens and extremities of cardiologists performing pacemaker implantation procedures in electrophysiology laboratory. The measurements were performed on one, widely used, portable C-arm system, first with x-ray tube mounted above the patient table and image intensifier below it and then on a reinstalled (but essentially the same) system with under-table x-ray tube configuration. Thermoluminescent dosimeters, placed in various positions near the eye lens, on the hands and ankle, were used during every procedure. The comparison of doses received by cardiologists after changing the x-ray tube configuration from over- to under-table shows statistically significant dose reduction (p < 0.009) for the eye lens closest to the x-ray tube, left finger, left wrist, while for the ankle a dose increase is observed. The corresponding over- to under-table x-ray tube median dose ratios are 4.1 for the right eye, 4.8 for the left finger, 3.0 for left wrist and, finally, 0.13 for the right ankle. Systems with under-table x-ray tube are preferable from a radiation protection point of view. The observed significant increase in doses to the legs should be partially compensated by the use of a protective lead curtain. (note)

  5. Role of B-scan ultrasonography in pre-operative cataract patients.

    Science.gov (United States)

    Qureshi, Manzoor A; Laghari, Khalida

    2010-01-01

    To visualize the posterior portion of eye globe in dense cataract patients with B scan ultrasound, and to find out any posterior segment lesion in such pre-operative cases. We performed diagnostic B-scan ultrasound on 750 cataract patients before surgery. This was a prospective diagnostic study which was conducted in the Department of Opthalmology, Liaquat University Eye Hospital, Hyderabad Sind, Pakistan from January 2007 to July 2007. Detailed history and some basic eye examination techniques, like slit lamp and tonometry were done in two groups of patients, traumatic (71) and non traumatic(679). Patients in the age range of 1 to 79 years of both sexes were included. Patients having already posterior segment lesions and those who had previous history of ocular surgery were excluded from the study. An ultrasound machine Nidek Echo Scan Model US-3300 with a probe of direct contact was used. Out of 750 patients, 90 patients had posterior segment lesions. Among traumatic group of 71 patients, 39 (55%) had positive posterior segment lesions, while in the non traumatic group of 679 patients, only 51 (7%) cases had positive posterior segment lesions. Out of the 90 positive cases, 25 (3%) had retinal detachment, 14 (2%) had posterior vitreous detachment, 24 (3%) had vitreous hemorrhage, 12 (2%) were asteroid hyolosis, while posterior staphyloma and intra-ocular foreign body were found with the frequency of 9 (1.2%) and 6 (1%), respectively. We concluded that two dimensional B-scan ultrasound can be one of the diagnostic tool for the detection of hidden posterior segment lesions and can be performed routinely in pre-operative cataract patients, as this would help in surgical planning. In cases, where a two dimensional B-scan is not sufficient or helpful. a three dimensional ultrasound would be justified.

  6. Could Buerger's disease cause nonarteritic anterior ischemic optic neuropathy?: a rare case report.

    Science.gov (United States)

    Korkmaz, Anil; Karti, Omer; Top Karti, Dilek; Yüksel, Bora; Zengin, Mehmet Ozgur; Kusbeci, Tuncay

    2018-04-05

    We present an interesting case with nonarteritic anterior ischemic optic neuropathy (NAION) accompanied by Buerger's disease. A 43-year-old man was referred to our neuro-ophthalmology clinic with a complaint of visual deterioration in the left eye that started 5 days ago. He suffered from Buerger's disease, and he had acute pain in the right lower limb below the knee. His best corrected visual acuity was 10/10 in the right eye and 2/10 in the left eye by Snellen chart. There was a relative afferent pupil defect in the left eye. The right optic disc was normal on fundus examination, and blurring, hemorrhagic swelling was found at the left optic disc. Inferior altitudinal visual field defect was observed in the left eye. Neurological examination was normal. Computed tomography angiography scan revealed occlusion in the right posterior tibial artery. Brain imaging and laboratory tests such as blood analyses, genetic screening, coagulation, and lipid panels were unremarkable. NAION may occur in patients with Buerger's disease, but it is extremely rare. Therefore, clinicians should be aware of this rare association.

  7. A randomized clinical evaluation of the safety of Systane® Lubricant Eye Drops for the relief of dry eye symptoms following LASIK refractive surgery

    Directory of Open Access Journals (Sweden)

    Daniel Durrie

    2008-12-01

    Full Text Available Daniel Durrie, Jason StahlDurrie Vision, Overland Park, Kansas, USAPurpose: To evaluate the safety of Systane® Lubricant Eye Drops in relieving the symptoms of dry eye following laser-assisted in situ keratomileusis (LASIK surgery.Methods: This was a randomized, double-masked, single-center, placebo-controlled, contralateral eye study of 30 patients undergoing LASIK surgery. The mean age of patients was 42.4 ± 10.7 years, and the mean spherical equivalent was −3.29 (range, +1.75 to −7.38. Patients’ right and left eyes were randomized to receive either Systane® or placebo – a preserved, thimerosal-free saline solution – beginning from the day of surgery and ending 30 days following surgery. Outcome measures included tear film break up time (TFBUT, visual acuity, degree of corneal and conjunctival staining, and treatment-related adverse events.Results: Preoperatively, placebo-treated eyes had statistically significantly higher sum corneal staining score than Systane®-treated eyes (p = 0.0464; however, the difference was clinically insignificant (p = 0.27. Two weeks post operatively, the average TFBUT in the Systane®-treated eyes was 1.23 seconds longer than that of the placebo-treated eyes (p = 0.028. All other evaluated variables were comparable between the two treatments. No adverse events were reported in the study.Conclusion: Systane® Lubricant Eye Drops are safe for use following LASIK surgery to relieve the discomfort symptoms of dry eye associated with the procedure.Keywords: Systane®, safety, dry eye, LASIK

  8. Characterization of Visual Scanning Patterns in Air Traffic Control.

    Science.gov (United States)

    McClung, Sarah N; Kang, Ziho

    2016-01-01

    Characterization of air traffic controllers' (ATCs') visual scanning strategies is a challenging issue due to the dynamic movement of multiple aircraft and increasing complexity of scanpaths (order of eye fixations and saccades) over time. Additionally, terminologies and methods are lacking to accurately characterize the eye tracking data into simplified visual scanning strategies linguistically expressed by ATCs. As an intermediate step to automate the characterization classification process, we (1) defined and developed new concepts to systematically filter complex visual scanpaths into simpler and more manageable forms and (2) developed procedures to map visual scanpaths with linguistic inputs to reduce the human judgement bias during interrater agreement. The developed concepts and procedures were applied to investigating the visual scanpaths of expert ATCs using scenarios with different aircraft congestion levels. Furthermore, oculomotor trends were analyzed to identify the influence of aircraft congestion on scan time and number of comparisons among aircraft. The findings show that (1) the scanpaths filtered at the highest intensity led to more consistent mapping with the ATCs' linguistic inputs, (2) the pattern classification occurrences differed between scenarios, and (3) increasing aircraft congestion caused increased scan times and aircraft pairwise comparisons. The results provide a foundation for better characterizing complex scanpaths in a dynamic task and automating the analysis process.

  9. Choroidal Excavation in Eye with Normal Tension Glaucoma

    Directory of Open Access Journals (Sweden)

    Kazunobu Asao

    2014-05-01

    Full Text Available Purpose: To report the case of an eye with normal tension glaucoma and a choroidal excavation. Methods: This is an observational case report. Results: A 59-year-old woman with normal tension glaucoma had a choroidal excavation in the left eye. Her best-corrected visual acuity and intraocular pressure were within normal limits and had been stable for 5 years. Fundus examination showed a small white lesion inferior to the macula and a nerve fiber layer defect at the inferior edge of the optic disc. Humphrey Field Analyzer (HFA showed visual field defects corresponding to the nerve fiber layer defect with C30-2, and a central scotoma superior to the macula with C10-2. Optical coherence tomography (OCT showed a 150-µm deep choroidal excavation. Disruptions of the IS/OS line were detected only in the area inferior to the choroidal excavation. During the 5 months of follow-up, her best-corrected visual acuity remained at 1.0 and the IOP ranged from 12 to 14 mm Hg in the left eye. The fundus and OCT images did not deteriorate and the choroidal excavation did not enlarge. Conclusions: The disruption of the inner/outer segment (IS/OS line was detected only at the area surrounding the choroidal excavation. OCT examinations are useful in assessing the area of the residual IS/OS line, and HFA can be used to estimate the residual central visual field.

  10. The eyes have it: Using eye tracking to inform information processing strategies in multi-attributes choices.

    Science.gov (United States)

    Ryan, Mandy; Krucien, Nicolas; Hermens, Frouke

    2018-04-01

    Although choice experiments (CEs) are widely applied in economics to study choice behaviour, understanding of how individuals process attribute information remains limited. We show how eye-tracking methods can provide insight into how decisions are made. Participants completed a CE, while their eye movements were recorded. Results show that although the information presented guided participants' decisions, there were also several processing biases at work. Evidence was found of (a) top-to-bottom, (b) left-to-right, and (c) first-to-last order biases. Experimental factors-whether attributes are defined as "best" or "worst," choice task complexity, and attribute ordering-also influence information processing. How individuals visually process attribute information was shown to be related to their choices. Implications for the design and analysis of CEs and future research are discussed. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Effects of emotionally affect adult and baby' photographs in healthy controls and schizophrenic patients evaluating by exploratory eye movements.

    Science.gov (United States)

    Kawabe, Chizuko; Morita, Kiichiro; Shoji, Yoshihisa; Fujiki, Ryo; Yamamoto, Atsushi; Asaumi, Yasue; Uchimura, Naohisa

    2011-01-01

    The relationship between mother and baby is of fundamental importance in the development of cognitive function and emotion. In this study we investigated the effects of affective photographs of a mother and baby (crying or smiling faces) and other stimuli (neutral mother or baby faces) on visual cognitive function in schizophrenic patents. We recorded exploratory eye movements in 22 healthy controls and 22 age-matched schizophrenic patients. Total number of right and left field gaze points (right TNGP, left TNGP) in the visual fields were determined using an eye-mark recorder as subjects viewed affectively charged or neutral photographs (crying, smiling or neutral faces). Left TNGP for all mother photographs (crying, smiling or neutral) were significantly larger in controls than patients, and right TNGP for neutral mother photographs were significantly larger in controls than in patients. Right TNGP for photographs of smiling babies were significantly larger in controls than patients, and left TNGP for photographs of both smiling and crying babies were significantly larger in controls than patients. Within the patient group, right TNGP were significantly larger than left TNGP for all mother photographs (crying, smiling or neutral). Left TNGP for photographs of mothers and babies correlated negatively with negative symptom scores. These results suggest that exploratory eye movements when viewing emotionally laded twin stimuli such as photographs of a mother and baby are a useful marker of visual cognitive function in both healthy controls and schizophrenic patients.

  12. Right Site, Wrong Route - Cannulating the Left Internal Jugular Vein.

    Science.gov (United States)

    Paik, Peter; Arukala, Sanjay K; Sule, Anupam A

    2018-01-09

    Central venous catheters are placed in approximately five million patients annually in the US. The preferred site of insertion is one with fewer risks and easier access. Although the right internal jugular vein is preferred, on occasion, the left internal jugular may have to be accessed. A patient was admitted for septic shock, cerebrovascular accident, and non-ST-segment elevation myocardial infarction. A central venous line was needed for antibiotic and vasopressor administration. Due to trauma from a fall to the right side and previously failed catheterization attempts at the left subclavian and femoral veins, the left internal jugular vein was accessed. On chest radiography for confirmation, the left internal jugular central venous catheter was seen projecting down the left paraspinal region. It did not take the expected course across the midline toward the right and into the superior vena cava (SVC). A review of a computed tomography (CT) scan of the chest with contrast done on a prior admission revealed a duplicated SVC on the left side that had not been reported in the original CT scan interpretation. A left-sided SVC is present in approximately 0.3% to 0.5% of the population, with 90% of these draining into the coronary sinus. During placements of central venous lines and pacemakers, irritation of the coronary sinus may result in hypotension, arrhythmia, myocardial ischemia, or cardiac arrest. A widened mediastinum can be an indication of a duplicated SVC. When attempting a left internal jugular vein central venous catheter placement, it is important to be aware of venous anomalies in order to prevent complications.

  13. Eye lens radiation exposure in Greek interventional cardiology personnel

    International Nuclear Information System (INIS)

    Thrapsanioti, Zoi; Askounis, Panagiotis; Carinou, Eleftheria; Datseris, Ioannis; Diamanti, Ramza Anastasia; Papathanasiou, Miltiadis

    2017-01-01

    The lens of the eye is one of the radiosensitive tissues of the human body; if exposed to ionizing radiation can develop radiation-induced cataract at early ages. This study was held in Greece and included 44 Interventional Cardiologists (ICs) and an unexposed to radiation control group of 22 persons. Of the note, 26 ICs and the unexposed individuals underwent special eye examinations. The detected lens opacities were classified according to LOCS III protocol. Additionally, the lens doses of the ICs were measured using eye lens dosemeters. The mean dose to the lenses of the ICs per month was 0.83 ± 0.59 mSv for the left and 0.35 ± 0.38 mSv for the right eye, while the annual doses ranged between 0.7 and 11 mSv. Regarding the lens opacities, the two groups did not differ significantly in the prevalence of either nuclear or cortical lens opacities, whereas four ICs were detected with early stage subcapsular sclerosis. Though no statistically difference was observed in the cohort, the measured doses indicate that the eye doses received from the ICs can be significant. To minimize the radiation-induced risk at the eye lenses, the use of protective equipment and appropriate training on this issue is highly recommended. (authors)

  14. CT evaluation of optic nerve compression in thyroid eye disease

    International Nuclear Information System (INIS)

    Barrett, L.; Giatt, H.J.; Burde, R.M.; Gado, M.

    1986-01-01

    In thyroid eye disease, visual loss due to optic nerve compression by enlarged muscles near the orbital apex requires prompt surgical decompression and must be differentiated from visual loss due to other mechanisms. Seventy-two high-resolution orbital CT scans of patients with thyroid eye disease were analyzed. From a coronal reconstruction, an easily measured ''apical index'' was determined. Average apical indices for orbits without optic neuropathy (41.0%) and with optic neuropathy (70.2%) were significantly different (P < .001). With the aid of the apical index, CT findings can be used to predict which patients with thyroid eye disease have optic nerve compression

  15. Communication Aid with Human Eyes Only

    Science.gov (United States)

    Arai, Kohei; Yajima, Kenro

    A communication aid with human eyes only is proposed. A set of candidate character is displayed onto computer screen of relatively small and light Head Mount Display: HMD that is mounted on glasses of which user wears on. When user looks at a candidate character with his/hers left eye while right eye picture is taken with small and light web camera that also is mounted on the glasses. The proposed system can selects 81 characters with two layers of 9 by 9 character candidate image. Other than these there is another selective image including control keys and frequently use of sentences. By using image matching between previously acquired template image for each candidate character and the currently acquired image, the proposed system realizes that which character in the candidates is selected. By using blinking and fix one's eye on combine together, the proposed system recognizes that user determines the selected key from the candidates. The blinking detection method employs a morphologic filter to avoid misunderstanding of dark eye detection due to eyebrows and shadows. Thus user can input sentences. User also may edit the sentences and then the sentences are read with Text to Speech: TTS software tool. Thus the system allows support conversations between handicapped and disabled persons without voice and the others peoples because only the function required for conversation is human eyes. Also the proposed system can be used as an input system for wearable computing systems. Test results by the 6 different able persons show that the proposed system does work with acceptable speed, around 1.5 second / character.

  16. Lung scan alterations in congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, R; Sanchez, J; Munoz, A; Lanaro, A E; Pico, A M

    1975-04-01

    This report analyzes the patterns in 54 lung scannings of 34 patients with altered pulmonary blood flow due to congenital heart disease. The technique and the results are presented. According to the images obtained, the patients are classified in three groups: Group I--normal distribution with more concentration of particles over the right lung and the bases. Group II--normal scannings found in left to right shunts unless there is pulmonary venous hypertension in which case the apex-base relationship was inverted. Group III--patients with right to left shunts of different types presenting various patterns according to severity, associated anomalies and palliative surgery. The hemodynamics created by cardiac defects and surgical procedures explain these alterations. This method is recommended in view of its advantages and accurate results.

  17. An evaluation of the left-brain vs. right-brain hypothesis with resting state functional connectivity magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Jared A Nielsen

    Full Text Available Lateralized brain regions subserve functions such as language and visuospatial processing. It has been conjectured that individuals may be left-brain dominant or right-brain dominant based on personality and cognitive style, but neuroimaging data has not provided clear evidence whether such phenotypic differences in the strength of left-dominant or right-dominant networks exist. We evaluated whether strongly lateralized connections covaried within the same individuals. Data were analyzed from publicly available resting state scans for 1011 individuals between the ages of 7 and 29. For each subject, functional lateralization was measured for each pair of 7266 regions covering the gray matter at 5-mm resolution as a difference in correlation before and after inverting images across the midsagittal plane. The difference in gray matter density between homotopic coordinates was used as a regressor to reduce the effect of structural asymmetries on functional lateralization. Nine left- and 11 right-lateralized hubs were identified as peaks in the degree map from the graph of significantly lateralized connections. The left-lateralized hubs included regions from the default mode network (medial prefrontal cortex, posterior cingulate cortex, and temporoparietal junction and language regions (e.g., Broca Area and Wernicke Area, whereas the right-lateralized hubs included regions from the attention control network (e.g., lateral intraparietal sulcus, anterior insula, area MT, and frontal eye fields. Left- and right-lateralized hubs formed two separable networks of mutually lateralized regions. Connections involving only left- or only right-lateralized hubs showed positive correlation across subjects, but only for connections sharing a node. Lateralization of brain connections appears to be a local rather than global property of brain networks, and our data are not consistent with a whole-brain phenotype of greater "left-brained" or greater "right

  18. Morphological features in eyes with endophthalmitis after cataract surgery – histopathology and optical coherence tomography assessment

    DEFF Research Database (Denmark)

    Solborg Bjerrum, Søren; Prause, Jan Ulrik; Fuchs, Helle Josefine

    2016-01-01

    limiting membrane (ILM) of the retina (14 eyes versus 3 eyes, p = 0.015) and a higher degree of retinal atrophy temporal to the fovea (13 eyes versus 1 eye, p = 0.013) compared to fellow eyes. The histopathological analyses showed the formation of epiretinal membranes, derangement of all retinal layers...... with a reduced number of nuclei in the nuclear layers, loss of photoreceptor outer segments and massive retinal gliosis. CONCLUSIONS: Optical coherence tomography scans of the retina and histopathology analyses provide insights in the pathological process occurring in PE....

  19. Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals

    Directory of Open Access Journals (Sweden)

    Nnamdi Norbert Jibiri

    2016-10-01

    Full Text Available Objective: The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Methods: Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. Results: The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP without cannula and with cannula were 10.68 (720.2 and 13.82 (556.4 mSv per week (and per annum, respectively. It was determined that the left hand of the personnel received higher doses than their right hand. Conclusion: The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99m

  20. DOME-SHAPED MACULA WITH THICKENED CHOROID IN AN EMMETROPIC PATIENT.

    Science.gov (United States)

    Kedkovid, Napang; Afshar, Armin R; Damato, Bertil E; Stewart, Jay M

    2015-01-01

    To report a rare case of bilateral dome-shaped macula in an emmetropic patient. Clinical case report and literature review. A 42-year-old woman presented with a history of blurred vision in the right eye. Visual acuity was 20/30 in the right eye and 20/20 in the left eye. Intraocular pressure and anterior segment were unremarkable. Fundus examination revealed dull macular reflex and subretinal fluid nasal to the fovea in the right eye and a hyperpigmented area inferotemporal to the fovea in the left eye. Spectral domain optical coherence tomography showed subretinal fluid under the fovea in the right eye and elevation of the macula with increased choroidal thickness in both eyes. Fluorescein angiography revealed abnormal hyperfluorescence without any leakage in both eyes. B-scan ultrasound showed irregular globe contour with high internal reflectivity and dome-shaped lesions at the posterior pole in both eyes. Axial length was 24.6 mm in the right eye and 25.6 mm in the left eye. Although most commonly reported in myopic eyes, dome-shaped macula can occur in an emmetropic patient and can be associated with subretinal fluid.

  1. Scanning Near-Field Optical Microscopy

    Directory of Open Access Journals (Sweden)

    Dušan Vobornik

    2008-02-01

    Full Text Available An average human eye can see details down to 0,07 mm in size. The ability to see smaller details of the matter is correlated with the development of the science and the comprehension of the nature. Today’s science needs eyes for the nano-world. Examples are easily found in biology and medical sciences. There is a great need to determine shape, size, chemical composition, molecular structure and dynamic properties of nano-structures. To do this, microscopes with high spatial, spectral and temporal resolution are required. Scanning Near-field Optical Microscopy (SNOM is a new step in the evolution of microscopy. The conventional, lens-based microscopes have their resolution limited by diffraction. SNOM is not subject to this limitation and can offer up to 70 times better resolution.

  2. Scanning near-field optical microscopy.

    Science.gov (United States)

    Vobornik, Dusan; Vobornik, Slavenka

    2008-02-01

    An average human eye can see details down to 0,07 mm in size. The ability to see smaller details of the matter is correlated with the development of the science and the comprehension of the nature. Today's science needs eyes for the nano-world. Examples are easily found in biology and medical sciences. There is a great need to determine shape, size, chemical composition, molecular structure and dynamic properties of nano-structures. To do this, microscopes with high spatial, spectral and temporal resolution are required. Scanning Near-field Optical Microscopy (SNOM) is a new step in the evolution of microscopy. The conventional, lens-based microscopes have their resolution limited by diffraction. SNOM is not subject to this limitation and can offer up to 70 times better resolution.

  3. Eye movement monitoring reveals differential influences of emotion on memory

    Directory of Open Access Journals (Sweden)

    Lily Riggs

    2010-11-01

    Full Text Available Research shows that memory for emotional aspects of an event may be enhanced at the cost of impaired memory for surrounding peripheral details. However, this has only been assessed directly via verbal reports which reveal the outcome of a long stream of processing but cannot shed light on how/when emotion may affect the retrieval process. In the present experiment, eye movement monitoring was used as an indirect measure of memory as it can reveal aspects of online memory processing. For example, do emotions modulate the nature of memory representations or the speed with which such memories can be accessed? Participants viewed central negative and neutral scenes surrounded by three neutral objects and after a brief delay, memory was assessed indirectly via eye movement monitoring and then directly via verbal reports. Consistent with the previous literature, emotion enhanced central and impaired peripheral memory as indexed by eye movement scanning and verbal reports. This suggests that eye movement scanning may contribute and/or is related to conscious access of memory. However, the central/peripheral tradeoff effect was not observed in an early measure of eye movement behavior, i.e. participants were faster to orient to a critical region of change in the periphery irrespective of whether it was previously studied in a negative or neutral context. These findings demonstrate emotion’s differential influences on different aspects of retrieval. In particular, emotion appears to affect the detail within, and/or the evaluation of, stored memory representations, but it may not affect the initial access to those representations.

  4. Confocal Adaptive Optics Imaging of Peripapillary Nerve Fiber Bundles: Implications for Glaucomatous Damage Seen on Circumpapillary OCT Scans.

    Science.gov (United States)

    Hood, Donald C; Chen, Monica F; Lee, Dongwon; Epstein, Benjamin; Alhadeff, Paula; Rosen, Richard B; Ritch, Robert; Dubra, Alfredo; Chui, Toco Y P

    2015-04-01

    To improve our understanding of glaucomatous damage as seen on circumpapillary disc scans obtained with frequency-domain optical coherence tomography (fdOCT), fdOCT scans were compared to images of the peripapillary retinal nerve fiber (RNF) bundles obtained with an adaptive optics-scanning light ophthalmoscope (AO-SLO). The AO-SLO images and fdOCT scans were obtained on 6 eyes of 6 patients with deep arcuate defects (5 points ≤-15 db) on 10-2 visual fields. The AO-SLO images were montaged and aligned with the fdOCT images to compare the RNF bundles seen with AO-SLO to the RNF layer thickness measured with fdOCT. All 6 eyes had an abnormally thin (1% confidence limit) RNF layer (RNFL) on fdOCT and abnormal (hyporeflective) regions of RNF bundles on AO-SLO in corresponding regions. However, regions of abnormal, but equal, RNFL thickness on fdOCT scans varied in appearance on AO-SLO images. These regions could be largely devoid of RNF bundles (5 eyes), have abnormal-appearing bundles of lower contrast (6 eyes), or have isolated areas with a few relatively normal-appearing bundles (2 eyes). There also were local variations in reflectivity of the fdOCT RNFL that corresponded to the variations in AO-SLO RNF bundle appearance. Relatively similar 10-2 defects with similar fdOCT RNFL thickness profiles can have very different degrees of RNF bundle damage as seen on fdOCT and AO-SLO. While the results point to limitations of fdOCT RNFL thickness as typically analyzed, they also illustrate the potential for improving fdOCT by attending to variations in local intensity.

  5. Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists

    International Nuclear Information System (INIS)

    Farah, J.; Jacob, S.; Clairand, I.; Struelens, L.; Vanhavere, F.; Auvinen, A.; Koukorava, C.; Schnelzer, M.

    2015-01-01

    In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose. (authors)

  6. Internal structure changes of eyelash induced by eye makeup.

    Science.gov (United States)

    Fukami, Ken-Ichi; Inoue, Takafumi; Kawai, Tomomitsu; Takeuchi, Akihisa; Uesugi, Kentaro; Suzuki, Yoshio

    2014-01-01

    To investigate how eye makeup affects eyelash structure, internal structure of eyelashes were observed with a scanning X-ray microscopic tomography system using synchrotron radiation light source. Eyelash samples were obtained from 36 Japanese women aged 20-70 years and whose use of eye makeup differed. Reconstructed cross-sectional images showed that the structure of the eyelash closely resembled that of scalp hair. The eyelash structure is changed by use of eye makeup. There was a positive correlation between the frequency of mascara use and the degree of cracking in cuticle. The positive correlation was also found between the frequency of mascara use and the porosity of the cortex. By contrast, the use of eyelash curler did not affect the eyelash structure with statistical significance.

  7. Ossification Vesicles with Calcium Phosphate in the Eyes of the Insect Copium teucrii (Hemiptera: Tingidae

    Directory of Open Access Journals (Sweden)

    Javier Garcia-Guinea

    2011-01-01

    Full Text Available Arthropod eyes are built of repeating units named ommatidia. Each single ommatidium unit contains a cluster of photoreceptor cells surrounded by support cells and pigment cells. The insect Copium eye ommatidia include additional calcium-phosphate deposits, not described in insects to date, which can be examined today using a combined set of modern microscopy and spectroscopy techniques. Teucrium gnaphalodes L'Her plants, growing in central Spain, develop galls induced by Copium insects. A survey of C. teucrii adult specimens resulted in surprising environmental scanning electron microscopy (ESEM images, showing that their bright red eyes contain a calcium-phosphate mineralization. A complete survey of Copium eye specimens was performed by ESEM using energy-dispersive spectroscopy, backscattered electron detector and cathodoluminescence (CL probes, field emission scanning electron microscopy, micro-Raman spectroscopy, and confocal laser scanning microscopy in order to learn ommatidia features, such as chemical composition, molecular structure, cell membrane, and internal ommatidium eye fluids and calcium-phosphate distribution deposits. The CL panchromatic images distinguish between the calcium-phosphate ommatidium and calcium-phosphate setae, which are more apatite rich. They show Raman bands attributable to bone tissue apatite biomaterials, such as bone, collagen, lipids, and blood, i.e., peptides, amide-S, amide-II, amide-III, and cytochrome P-450scc. The chemical composition of both galls and leaves of T. gnaphalodes was determined by gas chromatography – mass spectrometry (GC-MS of their extracts. The spectrometric and microscopic images reveal that the calcium-phosphate mineralization is formed and constrained to Copium ommatidia, which are both matrix vesicles generating mixtures of apatite collagen and operational compound eyes of the insect.

  8. Coupling Retinal Scanning Displays to the Human Visual System: Visual System Response and Engineering Considerations

    National Research Council Canada - National Science Library

    Turner, Stuart

    2002-01-01

    A retinal scanning display (RSD) is a visual display that presents an image to an observer via a modulated beam of light that is directed through the eye's pupil and rapidly scanned in a raster-like pattern across the retina...

  9. Altered intrinsic brain activities in patients with acute eye pain using amplitude of low-frequency fluctuation: a resting-state fMRI study

    Directory of Open Access Journals (Sweden)

    Pan Z

    2018-01-01

    Full Text Available Zhi-Ming Pan,1 Hai-Jun Li,1 Jing Bao,1 Nan Jiang,1 Qing Yuan,1 Shelby Freeberg,2 Pei-Wen Zhu,1 Lei Ye,1 Ming-Yang Ma,1 Xin Huang,1 Yi Shao1 1Department of Ophthalmology and Radiology, The First Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, People’s Republic of China; 2Department of Ophthalmology, University of Florida, Gainesville, FL, USA Objective: Many previous studies have reported that pain symptoms can lead to significant brain function and anatomical changes, whereas the intrinsic brain activity changes in acute eye pain (EP patients remain unknown. Using the amplitude of low-frequency fluctuation (ALFF method, this study aimed to evaluate the spontaneous brain activity alterations and their relationships with clinical features in acute EP patients.Participants and methods: A total of 20 patients with EP (15 males and 5 females and 20 healthy controls (HCs; 15 males and 5 females closely matched in age, sex, and education underwent resting-state functional magnetic resonance imaging scans. The ALFF method was applied to assess spontaneous brain activity changes. The ALFF values of the EP patients were distinguished from those of the HCs using a receiver operating characteristic curve. Pearson’s correlation analysis was used to investigate the relationships between the mean ALFF signal values from many brain regions and the clinical features in EP patients.Results: Compared with the HCs, acute EP patients had significantly lower ALFF in the left and right precentral/postcentral gyrus and left precuneus. In contrast, acute EP patients showed higher ALFF values in the right and left parahippocampal gyri and left caudate. However, no relationship was observed between the mean ALFF signal values from the different areas and clinical manifestations in the acute EP patients.Conclusion: We demonstrated that acute EP patients showed abnormal intrinsic brain activities in the precentral/postcentral gyrus and limbic system

  10. Quantification of the temporal component of left ventricular asynergy by gated cardiac blood pool scans

    International Nuclear Information System (INIS)

    Solot, G.; Chevigne, M.; Rigo, P.

    1985-01-01

    Fourier analysis (F) has demonstrated that left ventricular (LV) dysfunction can be analyzed in two separate component: an amplitude (AM) and a temporal (T) component. Although the former dominates in hypokinesis and akinesis, and the latter in dyskinesis, they are almost always associated and combine to determine the clinical form of asynergy (AS). The mechanical consequences of the T component cannot be assessed continuously by F which requires setting of a threshold. In this study, the authors have analyzed the potential of a new index; the stroke volume efficiency (SV Eff) to evaluate the importance of T AS in patients (pts) with coronary artery disease studied by gated blood pool scans. The authors have studied 14 controls, 8 pts with coronary artery disease without infarction, 56 pts with myocardial infarction (MI) and 21 pts with LV aneurysm. The SV Eff was calculated as follows after normalization and smoothing of the series: maximum and minimum images were created first and a LV region of interest was traced using the F AM image. The SV Eff ratio was calculated within the LV region of interest as ''diastolic counts - systolic counts/maximum counts - minimum counts''. The SV Eff in controls was 94% +- 2. The authors conclude that SV Eff provides a quantitative measurement of T component of LV dysfunction and an estimate of the dyskinetic component in pts with LV aneurysm. It should prove useful to study these patients serially

  11. Retinal Nerve Fiber Layer Segmentation on FD-OCT Scans of Normal Subjects and Glaucoma Patients.

    Science.gov (United States)

    Mayer, Markus A; Hornegger, Joachim; Mardin, Christian Y; Tornow, Ralf P

    2010-11-08

    Automated measurements of the retinal nerve fiber layer thickness on circular OCT B-Scans provide physicians additional parameters for glaucoma diagnosis. We propose a novel retinal nerve fiber layer segmentation algorithm for frequency domain data that can be applied on scans from both normal healthy subjects, as well as glaucoma patients, using the same set of parameters. In addition, the algorithm remains almost unaffected by image quality. The main part of the segmentation process is based on the minimization of an energy function consisting of gradient and local smoothing terms. A quantitative evaluation comparing the automated segmentation results to manually corrected segmentations from three reviewers is performed. A total of 72 scans from glaucoma patients and 132 scans from normal subjects, all from different persons, composed the database for the evaluation of the segmentation algorithm. A mean absolute error per A-Scan of 2.9 µm was achieved on glaucomatous eyes, and 3.6 µm on healthy eyes. The mean absolute segmentation error over all A-Scans lies below 10 µm on 95.1% of the images. Thus our approach provides a reliable tool for extracting diagnostic relevant parameters from OCT B-Scans for glaucoma diagnosis.

  12. Measurement of left-to-right shunts by gated radionuclide angiography: concise communication

    International Nuclear Information System (INIS)

    Rigo, P.; Chevigne, M.

    1982-01-01

    Gated cardiac blood-pool scans allow comparison of left- and right-ventricular stroke volume. We have applied these measurements to the quantification of left-to-right shunts (QP/QS) in nine patients with atrial septal defects, one patients with partial anomalous pulmonary venous return, four patients with ventricular septal defects, and two patients with patent ductus arteriosus. None of these patients had combined lesions. QP/QS was measured as the right-ventricular (RV) stroke counts divided by the left-ventricular (LV) stroke counts and as the LV stroke counts divided by the RV stroke counts in patients with RV and LV diastolic volume overload respectively. All patients had also QP/QS measurements by oximetry and first-pass radionuclide angiography. The stroke-count measurements indicated the overloaded ventricle in all patients. QP/QS determined by equilibrium gated studies correlated well with those obtained by oximetry (r . 0.79). Reproducibility of the equilibrium measurements was good. We conclude that gated cardiac blood-pool scans can measure left-to-right shunts and can distinguish between shunts with RV and LV volume overload

  13. Sideways displacement and curved path of recti eye muscles

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); F. Harting (Friedrich); B.J. de Waal (Bob); B.W.J.M. Verbeeten (Ben)

    1985-01-01

    textabstractWe investigated the sideways displacement of recti muscles with the eye in various gaze-positions by making computed tomographic (CT) scans in a plane perpendicular to the muscle cone, posterior to the globe. We found no consistent sideways displacement of the horizontal recti in the up

  14. Prevalence and Distribution of Segmentation Errors in Macular Ganglion Cell Analysis of Healthy Eyes Using Cirrus HD-OCT.

    Directory of Open Access Journals (Sweden)

    Rayan A Alshareef

    Full Text Available To determine the frequency of different types of spectral domain optical coherence tomography (SD-OCT scan artifacts and errors in ganglion cell algorithm (GCA in healthy eyes.Infrared image, color-coded map and each of the 128 horizontal b-scans acquired in the macular ganglion cell-inner plexiform layer scans using the Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA macular cube 512 × 128 protocol in 30 healthy normal eyes were evaluated. The frequency and pattern of each artifact was determined. Deviation of the segmentation line was classified into mild (less than 10 microns, moderate (10-50 microns and severe (more than 50 microns. Each deviation, if present, was noted as upward or downward deviation. Each artifact was further described as per location on the scan and zones in the total scan area.A total of 1029 (26.8% out of total 3840 scans had scan errors. The most common scan error was segmentation error (100%, followed by degraded images (6.70%, blink artifacts (0.09% and out of register artifacts (3.3%. Misidentification of the inner retinal layers was most frequent (62%. Upward Deviation of the segmentation line (47.91% and severe deviation (40.3% were more often noted. Artifacts were mostly located in the central scan area (16.8%. The average number of scans with artifacts per eye was 34.3% and was not related to signal strength on Spearman correlation (p = 0.36.This study reveals that image artifacts and scan errors in SD-OCT GCA analysis are common and frequently involve segmentation errors. These errors may affect inner retinal thickness measurements in a clinically significant manner. Careful review of scans for artifacts is important when using this feature of SD-OCT device.

  15. Histological study on the effect of He-Ne laser on the compound eyes of the locust Schistocerca Gregaria Forsk (Orthoptera-Acridiidae)

    International Nuclear Information System (INIS)

    Abd El-Meguid, A.; El-Gundi, A.M.; Osiris, W.G.; El-Kes, N.

    1996-01-01

    In the present study, the effect of the He-Ne laser beam at different exposure periods (10,30 and 60 minutes) on the histological structure of the compound eyes of Schistocerca Gregaria Forsk is investigated. This study shows that various remarkable changes occurred in the histological structure of the right exposed eye (R) as in the left eye (L) (unexposed eye of the same insect), which may be due to a change in the micro-environment of the compound eyes, affected by the laser beam, furthermore, damage in the photoreceptors of the compound eyes of the insect was observed. 23 figs

  16. B-mode ultrasonography biometry of the Amazon Parrot (Amazona aestiva) eye.

    Science.gov (United States)

    Lehmkuhl, Ricardo C; Almeida, Mariana F; Mamprim, Maria J; Vulcano, Luiz C

    2010-09-01

    Ultrasonographic evaluation of the eye is a relatively recent addition to routine ophthalmic diagnostics in small animal ophthalmology. Some parameters for ophthalmic biometry have been established. There are few studies in clinical avian ophthalmology that describe ultrasound images of eye in some nocturnal avian species and in other birds that do not belong to the Brazilian fauna, but the psittacine family is not represented. The purpose of this study was to describe the following measurements: the distances between cornea and anterior lens capsule (D1) between the anterior and posterior lens capsule (D2), between posterior lens capsule and optic papilla (D3) and the axial length. Sixty four transpalpebral ocular ultrasound examinations were performed on 32 Blue fronted Amazon parrots (Amazona aestiva) with no history of previous ophthalmic disease. The measurements were taken in sagital planes using a 10 MHz linear probe without a standoff pad. The mean values for the left eye were; D1 0.17 ± 0.03 cm, D2 0.35 ± 0.02 cm, D3 0.73 ± 0.04 cm and the axial length 1.26 ± 0.06 cm. In the right eye D1 0.17 ± 0.02 cm, D2 0.34 ± 0.02 cm, D3 0.74 ± 0.03 cm and the axial length 1.25 ± 0.05 cm. No significant statistical difference was observed among the birds or between the left and right eye. The description of these parameters will allow the veterinary practitioner to evaluate the structural changes that specific diseases may cause in these animals.

  17. A disappearing left-sided neck mass.

    Science.gov (United States)

    Lutwak, Nancy; Dill, Curt

    2012-07-04

    The patient was a 48-year-old man who presented to the emergency department with complaints of a left-sided painful neck mass, which changed in size relative to ingestion of meals. He denied voice change, fever, chills, weight loss, dysphagia and hoarseness. Physical examination was unremarkable. CT scan demonstrated a 3.9 mm calculus of the submandibular gland duct. Therapeutic sialendocopy was successfully performed.

  18. Recognition method of construction conflict based on driver's eye movement.

    Science.gov (United States)

    Xu, Yi; Li, Shiwu; Gao, Song; Tan, Derong; Guo, Dong; Wang, Yuqiong

    2018-04-01

    Drivers eye movement data in simulated construction conflicts at different speeds were collected and analyzed to find the relationship between the drivers' eye movement and the construction conflict. On the basis of the relationship between the drivers' eye movement and the construction conflict, the peak point of wavelet processed pupil diameter, the first point on the left side of the peak point and the first blink point after the peak point are selected as key points for locating construction conflict periods. On the basis of the key points and the GSA, a construction conflict recognition method so called the CCFRM is proposed. And the construction conflict recognition speed and location accuracy of the CCFRM are verified. The good performance of the CCFRM verified the feasibility of proposed key points in construction conflict recognition. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Isolated complete bitemporal hemianopia in traumatic chiasmal syndrome

    Directory of Open Access Journals (Sweden)

    Dai Woo Kim

    2013-01-01

    Full Text Available A 29-year-old man presented with a chief complaint of lateral blindness in the left eye at 4 months after an accidental fall. His best corrected visual acuity was 0.7 in the left eye and 1.0 in the right eye. Visual field test showed a complete bitemporal hemianopic defect without any neurologic symptoms. An orbital computed tomography scan with non-enhancement conducted at the time of the visit showed multiple frontal skull fractures and cerebromalacia a small fracture in the sphenoidal boneboth frontal lobes. No radiological abnormalities of the visual pathway were detected. Optical coherence showed reduced thickness in the retinal nerve fiber layer, primarily in the superior and inferior part of the left eye. To our knowledge, a complete bitemporal hemianopia without neurological deficits is extremely rare in traumatic chiasmal syndrome.

  20. Hyper-functioning Thyroid Nodule with Scintigraphic Owl's Eye Appearance

    International Nuclear Information System (INIS)

    Al-Kordi, R.S.; Elgazzar, A.H.

    2006-01-01

    Hyper-functioning thyroid nodules may produce various scintigraphic appearances on thyroid scans. Autonomously hyper functioning thyroid nodules invariably demonstrate degenerative changes. These changes may give rise to central or less commonly peripheral photopenic areas on a thyroid scan within otherwise a hot nodule. In this report we present a case of hyper functioning autonomous nodule with peripheral degeneration and residual central functioning tissue giving the appearance of an owl's eye. Although rare, this pattern can be seen in a variety of benign and malignant thyroid conditions. (author)

  1. Left-right cortical asymmetries of regional cerebral blood flow during listening to words

    DEFF Research Database (Denmark)

    Nishizawa, Y; Olsen, T S; Larsen, B

    1982-01-01

    1. Regional cerebral blood flow (rCBF) was measured during rest and during listening to simple words. The xenon-133 intracarotid technique was used and results were obtained from 254 regions of seven right hemispheres and seven left hemispheres. The measurements were performed just after carotid...... of the entire hemisphere. The focal rCBF increases were localized to the superior part of the temporal regions, the prefrontal regions, the frontal eye fields, and the orbitofrontal regions. Significant asymmetries were found in particular in the superior temporal region with the left side showing a more...

  2. MO-F-CAMPUS-I-04: Patient Eye-Lens Dose Reduction in Routine Brain CT Examinations Using Organ-Based Tube Current Modulation and In-Plane Bismuth Shielding

    International Nuclear Information System (INIS)

    Tsai, Hui-Yu; Liao, Ying-Lan; Lai, Nan-Ku; Chen, Tou-Rong; Chen, Jun-Rong

    2015-01-01

    Purpose: The purpose of this study is to assess eye-lens dose for patients who underwent brain CT examinations using two dose reduction Methods: organ-based tube current modulation (OBTCM) and in-plane bismuth shielding method. Methods: This study received institutional review board approval; written informed consent to participate was obtained from all patients. Ninety patients who underwent the routine brain CT examination were randomly assigned to three groups, ie. routine, OBTCM, and bismuth shield. The OBTCM technique reduced the tube current when the X-ray tube rotates in front of patients’ eye-lens region. The patients in the bismuth shield group were covered one-ply bismuth shield in the eyes’ region. Eye-lens doses were measured using TLD-100H chips and the total effective doses were calculated using CT-Expo according to the CT scanning parameters. The surface doses for patients at off-center positions were assessed to evaluate the off-centering effect. Results: Phantom measurements indicates that OBTCM technique could reduced by 26% to 28% of the surface dose to the eye lens, and increased by 25% of the surface dose at the opposed incident direction at the angle of 180°. Patients’ eye-lens doses were reduced 16.9% and 30.5% dose of bismuth shield scan and OBTCM scan, respectively compared to the routine scan. The eye-lens doses were apparently increased when the table position was lower than isocenter. Conclusion: Reducing the dose to the radiosensitive organs, such as eye lens, during routine brain CT examinations could lower the radiation risks. The OBTCM technique and in-plane bismuth shielding could be used to reduce the eye-lens dose. The eye-lens dose could be effectively reduced using OBTCM scan without interfering the diagnostic image quality. Patient position relative the CT gantry also affects the dose level of the eye lens. This study was supported by the grants from the Ministry of Science and Technology of Taiwan (MOST103-2314-B-182

  3. Stable isotopes in fish eye lenses as potential recorders of trophic and geographic history.

    Directory of Open Access Journals (Sweden)

    Amy A Wallace

    Full Text Available We evaluated eye lenses as potential recorders of stable isotope histories in fish because they consist of metabolically inert optical proteins that are deposited in successive, concentric circles (laminae much like otolith circuli and tree rings. We conducted four different tests on lenses from red snapper, red grouper, gag, and white grunt. The first test was a low-resolution screening of multiple individuals (4-5 radial groups of laminae per lens, all species except white grunt. Along the radial axis, all individuals exhibited substantial isotopic variability. Red snapper individuals separated into two groups based on δ15N and gag separated into two groups based on δ13C. Two gag with the greatest variation were chosen for high-resolution temporal analysis using individual laminae from their second eye lenses. The first-order patterns from the high-resolution analysis generally mimicked patterns from the low-resolution screening of grouped laminae, yet the high-resolution plots revealed early-life details that were not apparent in the low-resolution screenings. For the third test, left- versus right-eye variation was compared using high-resolution methods. White grunt left- and right-eye radial isotopic patterns were almost identical for both δ13C and δ15N, suggesting the variations observed among individual fish were not artifacts. The final test evaluated intra-laminar variation; multiple samples were analyzed from different parts of the same lamina. Seven laminae from three individuals of two species were analyzed in this manner; variations among laminae were found to be much higher than variations within laminae. However, nominal intra-laminar variations were comparable to nominal differences between left and right lenses, suggesting intra-laminar variation established measurement precision. Eye lens isotopes appear to be useful for reconstructing the isotopic histories of individual fish; these histories can be compared with spatially

  4. STAGE 5 RETINOPATHY OF PREMATURITY IN ONE EYE – CASE REPORT

    Directory of Open Access Journals (Sweden)

    Gordana Stanković-Babić

    2012-03-01

    Full Text Available Retinopathy of prematurity (ROP is a leading cause of blindness in children and one of the most important reasons of blindness in the perinatal period. The aim of the paper was to present a nine-month-old baby boy with esotropia, microphtalmos and completely detached retina in one eye, as the end stage of the disease, who had not been checked for ROP. The boy was born in the 32nd gestational week, with 1670 g birth weight. Indirect ophthalmoscope examination and ultrasonography of the left eye showed stage 5 retinopathy of prematurity. On the right eye, the finding was valid. Retinopathy of prematurity today needs recognition, understanding and awareness among ophthalmologists, pediatricians, neonatologists. Early diagnosis of damage is important in the treatment of ROP.

  5. Evaluation of baseline structural factors for predicting glaucomatous visual-field progression using optical coherence tomography, scanning laser polarimetry and confocal scanning laser ophthalmoscopy.

    Science.gov (United States)

    Sehi, M; Bhardwaj, N; Chung, Y S; Greenfield, D S

    2012-12-01

    The objective of this study is to assess whether baseline optic nerve head (ONH) topography and retinal nerve fiber layer thickness (RNFLT) are predictive of glaucomatous visual-field progression in glaucoma suspect (GS) and glaucomatous eyes, and to calculate the level of risk associated with each of these parameters. Participants with ≥28 months of follow-up were recruited from the longitudinal Advanced Imaging for Glaucoma Study. All eyes underwent standard automated perimetry (SAP), confocal scanning laser ophthalmoscopy (CSLO), time-domain optical coherence tomography (TDOCT), and scanning laser polarimetry using enhanced corneal compensation (SLPECC) every 6 months. Visual-field progression was assessed using pointwise linear-regression analysis of SAP sensitivity values (progressor) and defined as significant sensitivity loss of >1 dB/year at ≥2 adjacent test locations in the same hemifield at P<0.01. Cox proportional hazard ratios (HR) were calculated to determine the predictive ability of baseline ONH and RNFL parameters for SAP progression using univariate and multivariate models. Seventy-three eyes of 73 patients (43 GS and 30 glaucoma, mean age 63.2±9.5 years) were enrolled (mean follow-up 51.5±11.3 months). Four of 43 GS (9.3%) and 6 of 30 (20%) glaucomatous eyes demonstrated progression. Mean time to progression was 50.8±11.4 months. Using multivariate models, abnormal CSLO temporal-inferior Moorfields classification (HR=3.76, 95% confidence interval (CI): 1.02-6.80, P=0.04), SLPECC inferior RNFLT (per -1 μm, HR=1.38, 95% CI: 1.02-2.2, P=0.02), and TDOCT inferior RNFLT (per -1 μm, HR=1.11, 95% CI: 1.04-1.2, P=0.001) had significant HRs for SAP progression. Abnormal baseline ONH topography and reduced inferior RNFL are predictive of SAP progression in GS and glaucomatous eyes.

  6. Dissecting aneurysm of the cervical internal carotid artery. Cervical CT scan findings and treatment - case report

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Yoshihiro; Itoyama, Youichi; Fukumura, Akinobu; Matsukado, Yasuhiko; Kodama, Takafumi

    1987-06-01

    On lifting a heavy case, a 51-year-old male experienced a sudden onset of headache with giddiness and clouded vision. A week later, vertigo and right hand numbness were added to his symptoms. The next day anisocoria (right > left) and dilation of the left retinal veins were noted. Cranial computed tomography (CT) scan appeared normal and there were no other remarkable neurological findings. The patient was treated conservatively for cerebral infarction, however, the headache worsened and diplopia occurred. Neurological examination on admission revealed nothing unusual except for left Horner's syndrome. Physical examination showed a palpable sausage-like painless tumor on the left side of the neck. Angiography showed a narrowing of the internal carotid artery in the cervical region with a small dissecting aneurysm at the C3 level. Cervical CT scan at the upper C3 level showed a low density lunar defect in the high density section of the enlarged left internal carotid artery. The patient was operated on by superficial temporal artery-middle cerebral artery anastomosis to increase the intracranial blood flow. Postoperatively the symptoms were quickly relieved. Angiography 1 month later showed less narrowing of the carotid artery, though the dissecting aneurysm still remained. Postoperative cervical CT scan showed the left internal carotid artery to be of normal size. The patient returned to his work in normal condition 2 months later. It is emphasized that cervical CT scan may be useful in the diagnosis of this unusual type of cervical dissecting aneurysm.

  7. Real-time calibration-free C-scan images of the eye fundus using Master Slave swept source optical coherence tomography

    Science.gov (United States)

    Bradu, Adrian; Kapinchev, Konstantin; Barnes, Fred; Garway-Heath, David F.; Rajendram, Ranjan; Keane, Pearce; Podoleanu, Adrian G.

    2015-03-01

    Recently, we introduced a novel Optical Coherence Tomography (OCT) method, termed as Master Slave OCT (MS-OCT), specialized for delivering en-face images. This method uses principles of spectral domain interfereometry in two stages. MS-OCT operates like a time domain OCT, selecting only signals from a chosen depth only while scanning the laser beam across the eye. Time domain OCT allows real time production of an en-face image, although relatively slowly. As a major advance, the Master Slave method allows collection of signals from any number of depths, as required by the user. The tremendous advantage in terms of parallel provision of data from numerous depths could not be fully employed by using multi core processors only. The data processing required to generate images at multiple depths simultaneously is not achievable with commodity multicore processors only. We compare here the major improvement in processing and display, brought about by using graphic cards. We demonstrate images obtained with a swept source at 100 kHz (which determines an acquisition time [Ta] for a frame of 200×200 pixels2 of Ta =1.6 s). By the end of the acquired frame being scanned, using our computing capacity, 4 simultaneous en-face images could be created in T = 0.8 s. We demonstrate that by using graphic cards, 32 en-face images can be displayed in Td 0.3 s. Other faster swept source engines can be used with no difference in terms of Td. With 32 images (or more), volumes can be created for 3D display, using en-face images, as opposed to the current technology where volumes are created using cross section OCT images.

  8. Radiation Dose to the Lens of the Eye from Computed Tomography Scans of the Head

    Science.gov (United States)

    Januzis, Natalie Ann

    While it is well known that exposure to radiation can result in cataract formation, questions still remain about the presence of a dose threshold in radiation cataractogenesis. Since the exposure history from diagnostic CT exams is well documented in a patient's medical record, the population of patients chronically exposed to radiation from head CT exams may be an interesting area to explore for further research in this area. However, there are some challenges in estimating lens dose from head CT exams. An accurate lens dosimetry model would have to account for differences in imaging protocols, differences in head size, and the use of any dose reduction methods. The overall objective of this dissertation was to develop a comprehensive method to estimate radiation dose to the lens of the eye for patients receiving CT scans of the head. This research is comprised of a physics component, in which a lens dosimetry model was derived for head CT, and a clinical component, which involved the application of that dosimetry model to patient data. The physics component includes experiments related to the physical measurement of the radiation dose to the lens by various types of dosimeters placed within anthropomorphic phantoms. These dosimeters include high-sensitivity MOSFETs, TLDs, and radiochromic film. The six anthropomorphic phantoms used in these experiments range in age from newborn to adult. First, the lens dose from five clinically relevant head CT protocols was measured in the anthropomorphic phantoms with MOSFET dosimeters on two state-of-the-art CT scanners. The volume CT dose index (CTDIvol), which is a standard CT output index, was compared to the measured lens doses. Phantom age-specific CTDIvol-to-lens dose conversion factors were derived using linear regression analysis. Since head size can vary among individuals of the same age, a method was derived to estimate the CTDIvol-to-lens dose conversion factor using the effective head diameter. These conversion

  9. Foveal hemorrhage in an eye with foveal hypoplasia associated with albinism.

    Science.gov (United States)

    Masuda, Naonori; Hasegawa, Taiji; Yamashita, Mariko; Ogata, Nahoko

    2014-01-01

    Oculocutaneous albinism is a group of congenital disorders caused by alterations of melanin biosynthesis. We report our findings in a patient with oculocutaneous albinism who presented with foveal hypoplasia and a foveal hemorrhage. A 48-year-old man noted a dark spot in the middle of the visual field of his right eye. He had depigmented skin, white hair, white eyebrows, and white cilia. He also had horizontal nystagmus and depigmented irides. His best-corrected visual acuity was 2/100 with -14.0 diopters in the right eye and 3/100 with -5.0 diopters in the left eye. Ophthalmoscopy showed diffuse depigmentation in both eyes and a foveal hemorrhage in the right eye. Optical coherence tomography showed the absence of a foveal pit in both eyes and a subretinal hyperreflective lesion corresponding to the foveal hemorrhage in the right eye. Fluorescein angiography showed that the retinal and choroidal vessels were relatively hypofluorescent because of the lack of a blocking effect of the pigments in the retinal pigment epithelium. Fluorescein angiography and indocyanine green angiography did not show any evidence of choroidal neovascularization in either eye. The foveal hemorrhage in the right eye spontaneously regressed and finally resolved at 3 months after onset. At the final examination, the patient reported that his vision had recovered. A foveal hemorrhage is a rare condition in an eye with foveal hypoplasia associated with albinism. The hemorrhage may be related to high myopia and also to the hypoplasia of the fovea associated with albinism.

  10. Rapid computation of single PET scan rest-stress myocardial blood flow parametric images by table look up.

    Science.gov (United States)

    Guehl, Nicolas J; Normandin, Marc D; Wooten, Dustin W; Rozen, Guy; Ruskin, Jeremy N; Shoup, Timothy M; Woo, Jonghye; Ptaszek, Leon M; Fakhri, Georges El; Alpert, Nathaniel M

    2017-09-01

    We have recently reported a method for measuring rest-stress myocardial blood flow (MBF) using a single, relatively short, PET scan session. The method requires two IV tracer injections, one to initiate rest imaging and one at peak stress. We previously validated absolute flow quantitation in ml/min/cc for standard bull's eye, segmental analysis. In this work, we extend the method for fast computation of rest-stress MBF parametric images. We provide an analytic solution to the single-scan rest-stress flow model which is then solved using a two-dimensional table lookup method (LM). Simulations were performed to compare the accuracy and precision of the lookup method with the original nonlinear method (NLM). Then the method was applied to 16 single scan rest/stress measurements made in 12 pigs: seven studied after infarction of the left anterior descending artery (LAD) territory, and nine imaged in the native state. Parametric maps of rest and stress MBF as well as maps of left (f LV ) and right (f RV ) ventricular spill-over fractions were generated. Regions of interest (ROIs) for 17 myocardial segments were defined in bull's eye fashion on the parametric maps. The mean of each ROI was then compared to the rest (K 1r ) and stress (K 1s ) MBF estimates obtained from fitting the 17 regional TACs with the NLM. In simulation, the LM performed as well as the NLM in terms of precision and accuracy. The simulation did not show that bias was introduced by the use of a predefined two-dimensional lookup table. In experimental data, parametric maps demonstrated good statistical quality and the LM was computationally much more efficient than the original NLM. Very good agreement was obtained between the mean MBF calculated on the parametric maps for each of the 17 ROIs and the regional MBF values estimated by the NLM (K 1map LM  = 1.019 × K 1 ROI NLM  + 0.019, R 2  = 0.986; mean difference = 0.034 ± 0.036 mL/min/cc). We developed a table lookup method for fast

  11. EyeMusic: Making Music with the Eyes

    OpenAIRE

    Hornof, Anthony J.; Sato, Linda

    2004-01-01

    Though musical performers routinely use eye movements to communicate with each other during musical performances, very few performers or composers have used eye tracking devices to direct musical compositions and performances. EyeMusic is a system that uses eye movements as an input to electronic music compositions. The eye movements can directly control the music, or the music can respond to the eyes moving around a visual scene. EyeMusic is implemented so that any composer using established...

  12. Comparative eye-tracking evaluation of scatterplots and parallel coordinates

    Directory of Open Access Journals (Sweden)

    Rudolf Netzel

    2017-06-01

    Full Text Available We investigate task performance and reading characteristics for scatterplots (Cartesian coordinates and parallel coordinates. In a controlled eye-tracking study, we asked 24 participants to assess the relative distance of points in multidimensional space, depending on the diagram type (parallel coordinates or a horizontal collection of scatterplots, the number of data dimensions (2, 4, 6, or 8, and the relative distance between points (15%, 20%, or 25%. For a given reference point and two target points, we instructed participants to choose the target point that was closer to the reference point in multidimensional space. We present a visual scanning model that describes different strategies to solve this retrieval task for both diagram types, and propose corresponding hypotheses that we test using task completion time, accuracy, and gaze positions as dependent variables. Our results show that scatterplots outperform parallel coordinates significantly in 2 dimensions, however, the task was solved more quickly and more accurately with parallel coordinates in 8 dimensions. The eye-tracking data further shows significant differences between Cartesian and parallel coordinates, as well as between different numbers of dimensions. For parallel coordinates, there is a clear trend toward shorter fixations and longer saccades with increasing number of dimensions. Using an area-of-interest (AOI based approach, we identify different reading strategies for each diagram type: For parallel coordinates, the participants’ gaze frequently jumped back and forth between pairs of axes, while axes were rarely focused on when viewing Cartesian coordinates. We further found that participants’ attention is biased: toward the center of the whole plotfor parallel coordinates and skewed to the center/left side for Cartesian coordinates. We anticipate that these results may support the design of more effective visualizations for multidimensional data.

  13. A rare combination of cardiopulmonary anomalies demonstrated on ventilation-perfusion scan

    International Nuclear Information System (INIS)

    Khan, S.; Dunn, J.; Al-Nahhas, A.; Ariff, B.; Juli, C.; Karunanithy, N.; Strickland, N.

    2008-01-01

    In this case report we describe an unusual appearance seen on a ventilation-perfusion (V/Q) scan in a woman with pulmonary hypertension. Although the pulmonary hypertension was not caused by pulmonary emboli, the V/Q scan suggested several cardiac anomalies which may lead to pulmonary hypertension. Most of the cardiac anomalies, including right-sided aortic arch and right-to-left shunt, can be deduced from careful examination of the V/Q scan. A subsequent cardiac MRI scan confirmed the anomalies. (authors)

  14. Sub-Airy Confocal Adaptive Optics Scanning Ophthalmoscopy.

    Science.gov (United States)

    Sredar, Nripun; Fagbemi, Oladipo E; Dubra, Alfredo

    2018-04-01

    To demonstrate the viability of improving transverse image resolution in reflectance scanning adaptive optics ophthalmoscopy using sub-Airy disk confocal detection. The foveal cone mosaic was imaged in five human subjects free of known eye disease using two custom adaptive optics scanning light ophthalmoscopes (AOSLOs) in reflectance with 7.75 and 4.30 mm pupil diameters. Confocal pinholes of 0.5, 0.6, 0.8, and 1.0 Airy disk diameters (ADDs) were used in a retinal conjugate plane before the light detector. Average cone photoreceptor intensity profile width and power spectrum were calculated for the resulting images. Detected energy using a model eye was recorded for each pinhole size. The cone photoreceptor mosaic is better resolved with decreasing confocal pinhole size, with the high spatial frequency content of the images enhanced in both the large- and small-pupil AOSLOs. The average cone intensity profile width was reduced by ∼15% with the use of a 0.5 ADD pinhole when compared to a 1.0 ADD, with an accompanying reduction in signal greater than a factor of four. The use of sub-Airy disk confocal pinhole detection without increasing retinal light exposure results in a substantial improvement in image resolution at the cost of larger than predicted signal reduction. Improvement in transverse resolution using sub-Airy disk confocal detection is a practical and low-cost approach that is applicable to all point- and line-scanning ophthalmoscopes, including optical coherence tomographers.

  15. Near-infrared reflectance bull’s eye maculopathy as an early indication of hydroxychloroquine toxicity

    Directory of Open Access Journals (Sweden)

    Wong KL

    2015-03-01

    Full Text Available Keye L Wong,1 Scott E Pautler,2 David J Browning31Retina Associates of Sarasota, Sarasota, FL, USA; 2Retina Vitreous Associates of Florida, Tampa, FL, USA; 3Charlotte Eye Ear Nose and Throat Associates, Charlotte, NC, USAImportance: In some patients, hydroxychloroquine ocular toxicity may progress even following cessation of therapy. Any leverage the clinician may use to allow earlier detection may avert significant vision loss.Observation: We report three cases suggesting that bull’s eye maculopathy seen on near-infrared reflectance with a confocal scanning laser ophthalmoscope could be an early, objective manifestation of hydroxychloroquine ocular toxicity, and with progression of the disease this near-infrared “bull’s eye” change may disappear.Conclusion and relevance: Alerting clinicians to this observation may allow a larger case series to corroborate the hypothesis that bull’s eye maculopathy detected by near-infrared reflectance may represent an early sign of hydroxychloroquine toxicity.Keywords: confocal, scanning laser ophthalmoscope, multifocal ERG

  16. Tc-99m pyrophosphate scanning after ischemic exercise in McArdle's disease

    International Nuclear Information System (INIS)

    Uno, Hideaki; Kawano, Keizo; Yukawa, Susumu; Nomoto, Hiroshi

    1982-01-01

    In order to clarify the mechanism of muscle contracture induced by ischemic exercise in a patient with McArdle's disease, bone scanning with Tc-99m pyrophosphate was performed. The clinical diagnosis was established in the patient based on the biochemical examinations of skeletal muscle biopsy. Ischemic exercise was done initially on the left forearm and then 20 hours later on the right forearm. Two hours later, 15 mCi of Tc-99m pyrophosphate was infused through the left antecubital vein. Exactly 4 hours later, a conventional bone scanning was carried out. In the patient with McArdle's disease, muscle contracture developed in both forearms during the ischemic exercise. Conventional bone scanning showed increased Tc-99m pyrophosphate labeling of the right forearm muscles at 2 hours after ischemic exercise. However, increased labeling of the left forearm muscles was not found at 22 hours after ischemic exercise. In the control, no muscle contracture developed during ischemic exercise and bone scan showed no increase in Tc-99m pyrophosphate labeling in the antebrachial region. These findings suggest that the basis of muscle contracture appears to be an increased concentration of Ca in muscle cells due to a failure of sarcoplasmic reticulum to reaccumulate Ca at ischemic exercise. (author)

  17. Effect of laser peripheral iridotomy on anterior chamber angle anatomy in primary angle closure spectrum eyes

    Science.gov (United States)

    Kansara, Seema; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Bell, Nicholas P.; Mankiewicz, Kimberly A.; Feldman, Robert M.

    2015-01-01

    Purpose To evaluate the change in trabecular-iris circumference volume (TICV) after laser peripheral iridotomy (LPI) in primary angle closure (PAC) spectrum eyes Patients and Methods Forty-two chronic PAC spectrum eyes from 24 patients were enrolled. Eyes with anterior chamber abnormalities affecting angle measurement were excluded. Intraocular pressure, slit lamp exam, and gonioscopy were recorded at each visit. Anterior segment optical coherence tomography (ASOCT) with 3D mode angle analysis scans were taken with the CASIA SS-1000 (Tomey Corp., Nagoya, Japan) before and after LPI. Forty-two pre-LPI ASOCT scans and 34 post-LPI ASOCT scans were analyzed using the Anterior Chamber Analysis and Interpretation (ACAI, Houston, TX) software. A mixed-effect model analysis was used to compare the trabecular-iris space area (TISA) changes among 4 quadrants, as well as to identify potential factors affecting TICV. Results There was a significant increase in all average angle parameters after LPI (TISA500, TISA750, TICV500, and TICV750). The magnitude of change in TISA500 in the superior angle was significantly less than the other angles. The changes in TICV500 and TICV750 were not associated with any demographic or ocular characteristics. Conclusion TICV is a useful parameter to quantitatively measure the effectiveness of LPI in the treatment of eyes with PAC spectrum disease. PMID:26066504

  18. Opaque iris claw lens in a phakic eye to correct acquired diplopia

    NARCIS (Netherlands)

    Landesz, M; Worst, JGF; Rij, GV; Houtman, WA

    1997-01-01

    A 25-year-old man had diplopia caused by abducens nerve paresis on both sides after cranial injury. Because of the patient's reports of persistent diplopia after surgical correction, a specially manufactured, tinted iris claw lens was implanted in the left eye, with the crystalline lens in situ.

  19. Understanding eye movements in face recognition using hidden Markov models.

    Science.gov (United States)

    Chuk, Tim; Chan, Antoni B; Hsiao, Janet H

    2014-09-16

    We use a hidden Markov model (HMM) based approach to analyze eye movement data in face recognition. HMMs are statistical models that are specialized in handling time-series data. We conducted a face recognition task with Asian participants, and model each participant's eye movement pattern with an HMM, which summarized the participant's scan paths in face recognition with both regions of interest and the transition probabilities among them. By clustering these HMMs, we showed that participants' eye movements could be categorized into holistic or analytic patterns, demonstrating significant individual differences even within the same culture. Participants with the analytic pattern had longer response times, but did not differ significantly in recognition accuracy from those with the holistic pattern. We also found that correct and wrong recognitions were associated with distinctive eye movement patterns; the difference between the two patterns lies in the transitions rather than locations of the fixations alone. © 2014 ARVO.

  20. Paucity of bone scan abnormalities in a child with multifocal osteomyelitis and disseminated sepsis

    International Nuclear Information System (INIS)

    Trpezanovski, J.; Porn, U.; Uren, R.; Howman-Giles, R.; Mansberg, R.

    2000-01-01

    Full text: We present an unusual case of multifocal osteomyelitis with minimal bone scan abnormalities and markedly discordant findings on Magnetic Resonance Imaging(MRI) and gallium scans. A seven-year-old female presented with left leg, right elbow pain and fever. A bone scan was performed. Mild increased vascularity was demonstrated on the dynamic and blood pool phases of the study in the area of the right elbow. In the delayed images there was a photopenic lesion in the left distal femoral metadiaphysis and also irregular uptake in the metaphyseal regions of the long bones. Low grade soft tissue tracer uptake was seen in the left thigh and right forearm. The patient deteriorated clinically and underwent further investigations with MRI and gallium scans. The MRI showed extensive abnormalities with mulitlocular fluid collection seen throughout most of the muscle groups of both thighs suggesting myositis with an associated cellulitis and osteomyelitis of the left femur. The gallium study was markedly abnormal with increased uptake in the distal 2/3rds of the left femur, proximal 1/2 of the right femur, right proximal forearm (mid forearm extending to mid upper arm), left proximal humerus and right hemithorax especially the lower zones. Staphylococcal aureus was cultured. The patient required intensive care management and slowly responded to antibiotic therapy and surgery to drain abscesses in the thighs. A bone marrow biopsy was normal and immunological tests were performed but a result has yet to be determined. The lack of increased bone uptake in the demonstrated areas of osteomyelitis maybe explained on the basis of an overwhelming infective process inhibiting the patient's healing response. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  1. Connecting eye to eye

    DEFF Research Database (Denmark)

    Dau, Susanne; Rask, Anders Bindslev

    2017-01-01

    Computer Supported Collaborative Learning (CSCL) is used a frame for supporting online and blended learning in educations. The online communication and collaboration are afforded by the social collaboration. However, the social collaboration is based on the establishment of direct eye contact...... (Khalid, Deska & Hugenberg, 2016), but direct eye contact is challenged by the position of the digital devices and thus CSCL. Lack of eye contact is the chief contributor to the negative effects of online disinhibition (Lapidot-Lefler & Barak, 2012) and the problem is the location of the web camera...... at the computer. Eye contact is challenged by the displacement between the senders´ and receivers´ focus on the screen picture and the camera's location at the top or bottom of screens on all digital devices. The aim of this paper is accordingly to investigate the influence of the displacement in eye contact...

  2. Caucasian infants scan own- and other-race faces differently.

    Directory of Open Access Journals (Sweden)

    Andrea Wheeler

    2011-04-01

    Full Text Available Young infants are known to prefer own-race faces to other race faces and recognize own-race faces better than other-race faces. However, it is entirely unclear as to whether infants also attend to different parts of own- and other-race faces differently, which may provide an important clue as to how and why the own-race face recognition advantage emerges so early. The present study used eye tracking methodology to investigate whether 6- to 10-month-old Caucasian infants (N = 37 have differential scanning patterns for dynamically displayed own- and other-race faces. We found that even though infants spent a similar amount of time looking at own- and other-race faces, with increased age, infants increasingly looked longer at the eyes of own-race faces and less at the mouths of own-race faces. These findings suggest experience-based tuning of the infant's face processing system to optimally process own-race faces that are different in physiognomy from other-race faces. In addition, the present results, taken together with recent own- and other-race eye tracking findings with infants and adults, provide strong support for an enculturation hypothesis that East Asians and Westerners may be socialized to scan faces differently due to each culture's conventions regarding mutual gaze during interpersonal communication.

  3. Dissecting aneurysm of the cervical internal carotid artery. Cervical CT scan findings and treatment - case report

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Yoshihiro; Itoyama, Youichi; Fukumura, Akinobu; Matsukado, Yasuhiko; Kodama, Takafumi

    1987-06-01

    On lifting a heavy case, a 51-year-old male experienced a sudden onset of headache with giddiness and clouded vision. A week later, vertigo and right hand numbness were added to his symptoms. The next day anisocoria (right > left) and dilation of the left retinal veins were noted. Cranial computed tomography (CT) scan appeared normal and there were no other remarkable neurological findings. The patient was treated conservatively for cerebral infarction, however, the headache worsened and diplopia occurred. Neurological examination on admission revealed nothing unusual except for left Horner's syndrome. Physical examination showed a palpable sausage-like painless tumor on the left side of the neck. Angiography showed a narrowing of the internal carotid artery in the cervical region with a small dissecting aneurysm at the C3 level. Cervical CT scan at the upper C3 level showed a low density lunar defect in the high density section of the enlarged left internal carotid artery. The patient was operated on by superficial temporal artery-middle cerebral artery anastomosis to increase the intracranial blood flow. Postoperatively the symptoms were quickly relieved. Angiography 1 month later showed less narrowing of the carotid artery, though the dissecting aneurysm still remained. Postoperative cervical CT scan showed the left internal carotid artery to be of normal size. The patient returned to his work in normal condition 2 months later. It is emphasized that cervical CT scan may be useful in the diagnosis of this unusual type of cervical dissecting aneurysm.

  4. Foveal hemorrhage in an eye with foveal hypoplasia associated with albinism

    Directory of Open Access Journals (Sweden)

    Masuda N

    2014-09-01

    Full Text Available Naonori Masuda, Taiji Hasegawa, Mariko Yamashita, Nahoko Ogata Department of Ophthalmology, Nara Medical University, Nara, Japan Abstract: Oculocutaneous albinism is a group of congenital disorders caused by alterations of melanin biosynthesis. We report our findings in a patient with oculocutaneous albinism who presented with foveal hypoplasia and a foveal hemorrhage. A 48-year-old man noted a dark spot in the middle of the visual field of his right eye. He had depigmented skin, white hair, white eyebrows, and white cilia. He also had horizontal nystagmus and depigmented irides. His best-corrected visual acuity was 2/100 with -14.0 diopters in the right eye and 3/100 with -5.0 diopters in the left eye. Ophthalmoscopy showed diffuse depigmentation in both eyes and a foveal hemorrhage in the right eye. Optical coherence tomography showed the absence of a foveal pit in both eyes and a subretinal hyperreflective lesion corresponding to the foveal hemorrhage in the right eye. Fluorescein angiography showed that the retinal and choroidal vessels were relatively hypofluorescent because of the lack of a blocking effect of the pigments in the retinal pigment epithelium. Fluorescein angiography and indocyanine green angiography did not show any evidence of choroidal neovascularization in either eye. The foveal hemorrhage in the right eye spontaneously regressed and finally resolved at 3 months after onset. At the final examination, the patient reported that his vision had recovered. A foveal hemorrhage is a rare condition in an eye with foveal hypoplasia associated with albinism. The hemorrhage may be related to high myopia and also to the hypoplasia of the fovea associated with albinism. Keywords: albinism, foveal hemorrhage, foveal hypoplasia, simple hemorrhage

  5. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, D. [Toshiba America Medical Systems (United States)

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  6. TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  7. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    International Nuclear Information System (INIS)

    Zhang, D.

    2015-01-01

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  8. TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

    International Nuclear Information System (INIS)

    2015-01-01

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  9. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Leer en Español: ¿Qué son las alergias de ...

  10. Radiation doses to the eye lenses in computed tomography of the orbit and the petrous bone

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Zanella, F.E.; Ewen, K.; Koeln Univ.

    1987-01-01

    Standard CT examinations of the orbit and the petrous bone were simulated with a tissue-equivalent human skull phantom on a Somatom DR 2 scanner. The orientation of the scan planes and the scan parameters including thickness, number of slices and mAs were varied according to the assumed diagnostic problems. The total radiation doses in the region of the eye lenses were measured with thermoluminescent dosimeters. If the globes are located within the X-ray field, the total radiation doses received by the lenses increased with the number and the thickness of the slices and the mAs. The highest radiation doses were found in contiguous thinsection scans of the orbit in axial (52 mGy) or direct coronal (47 mGy) orientation. In cases where the globes were located outside the X-ray field, the radiation doses received by the eye lenses could be reduced by a factor of 16, resulting in only 3.1-3.4 mGy for a complete axial study of the inner ear. Recommendations are given how to reduce the radiation exposure to the eye lenses without loss of diagnostical information. (orig.)

  11. Glaucoma diagnostic performance of GDxVCC and spectralis OCT on eyes with atypical retardation pattern.

    Science.gov (United States)

    Hoesl, Laura Maria; Tornow, Ralf P; Schrems, Wolfgang A; Horn, Folkert K; Mardin, Christian Y; Kruse, Friedrich E; Juenemann, Anselm G M; Laemmer, Robert

    2013-01-01

    To investigate the impact of typical scan score (TSS) on discriminating glaucomatous and healthy eyes by scanning laser polarimetry and spectral domain optical coherence tomography (SD-OCT) in 32 peripapillary sectors. One hundred two glaucoma patients and 32 healthy controls underwent standard automated perimetry, 24-hour intraocular pressure profile, optic disc photography, GDxVCC, and SD-OCT measurements. For controls, only very typical scans (TSS=100) were accepted. Glaucoma patients were divided into 3 subgroups (very typical: TSS=100; typical: 99≥TSS≥80, atypical: TSS<80). Receiver operating characteristic curves were constructed for mean retinal nerve fiber layer values, sector data, and nerve fiber indicator (NFI). Sensitivity was estimated at ≥90% specificity to compare the discriminating ability of each imaging modality. For discrimination between healthy and glaucomatous eyes with very typical scans, the NFI and inferior sector analyses 26 to 27 demonstrated the highest sensitivity at ≥90% specificity in GDxVCC and SD-OCT, respectively. For the typical and atypical groups, sensitivity at ≥90% specificity decreased for all 32 peripapillary sectors on an average by 10.9% and 17.9% for GDxVCC and by 4.9% and 0.8% for SD-OCT. For GDxVCC, diagnostic performance of peripapillary sectors decreased with lower TSS, especially in temporosuperior and inferotemporal sectors (sensitivity at ≥90% specificity decreased by 55.3% and by 37.8% in the atypical group). Diagnostic accuracy is comparable for SD-OCT and GDxVCC if typical scans (TSS=100) are investigated. Decreasing TSS is associated with a decrease in diagnostic accuracy for discriminating healthy and glaucomatous eyes by scanning laser polarimetry. NFI is less influenced than the global or sector retinal nerve fiber layer thickness. The TSS score should be included in the standard printout. Diagnostic accuracy of SD-OCT is barely influenced by low TSS.

  12. Binocular fusion and invariant category learning due to predictive remapping during scanning of a depthful scene with eye movements

    OpenAIRE

    Grossberg, Stephen; Srinivasan, Karthik; Yazdanbakhsh, Arash

    2015-01-01

    How does the brain maintain stable fusion of 3D scenes when the eyes move? Every eye movement causes each retinal position to process a different set of scenic features, and thus the brain needs to binocularly fuse new combinations of features at each position after an eye movement. Despite these breaks in retinotopic fusion due to each movement, previously fused representations of a scene in depth often appear stable. The 3D ARTSCAN neural model proposes how the brain does this by unifying ...

  13. Analysis of the correlation between tear film changes of allergic conjunctivitis and dry eye

    Directory of Open Access Journals (Sweden)

    Yong Li

    2014-07-01

    Full Text Available AIM: To analyze the correlation between tear film changes of allergic conjunctivitis and dry eye, then provide clinical references for better treatment. METHODS: Fifty patients with allergic conjunctivitis were taken as the observation group, the control group was selected based on 1:1 case control theory, and we chose 50 health volunteers without ocular surface diseases, xerophthalmia and systematic diseases randomly, then fluorescein(FLstaining, break-up time(BUT, Schirner I test(SⅠt, tear meniscus high(TMHand slit-lamp examinations were performed in the two groups. RESULTS: In the observation group, FL, BUT, SIt, TMH of right eyes and left eyes were statistically significant correlated(PPPCONCLUSION: Due to inflammatory mediators participation, allergic conjunctivitis could lead to the stability changes of tear film which cause in dry eye. The stability changes of allergic conjunctivitis correlate to the damage degree of epithelium.

  14. HORIZONTAL RIDGE AS A POSTERIOR POLE FINDING IN A HIGHLY MYOPIC EYE WITH DOME-SHAPED MACULA.

    Science.gov (United States)

    Liang, I Chia

    2017-07-01

    This article describes a case with a highly myopic eye and a posterior pole with ridge-like lesions. Case report. A 72-year-old man with unilateral high myopia showed poor vision and an extremely elongated axial length in his right eye, but normal vision and normal axial length in his left eye. He was examined using fundus examination and optical coherence tomography, and revealed to have dome-shaped macula with two horizontal ridges connecting the optic disc and the macula in his highly-myopic eye. The findings suggest that a dome-shaped macula may not be limited to the macula area, but may involve the whole posterior pole and is potentially involved in the elongation of highly myopic eyeballs.

  15. CHOROIDAL CHANGES ASSOCIATED WITH SEROUS MACULAR DETACHMENT IN EYES WITH STAPHYLOMA, DOME-SHAPED MACULA OR TILTED DISK SYNDROME.

    Science.gov (United States)

    Tan, Anna C S; Yzer, Suzanne; Freund, K Bailey; Dansingani, Kunal K; Phasukkijwatana, Nopasak; Sarraf, David

    2017-08-01

    To study the relationship of choroidal abnormalities with serous retinal detachment (SRD) in eyes with staphyloma, dome-shaped macula, or tilted disk syndrome. Group 1, 28 eyes of 20 patients with staphyloma/dome-shaped macula/tilted disk syndrome associated with SRD was compared with Group 2, 30 eyes of 20 patients, with staphyloma/dome-shaped macula/tilted disk syndrome but without SRD. Radial and en-face optical coherence tomography and choroidal analysis were performed. Group 1 had a thicker mean subfoveal choroidal thickness (161 μm vs. 92 μm, P 0.05) compared with eyes of Group 2. Focal abrupt changes in choroidal thickness were more commonly seen in Group 1 versus eyes in Group 2 (90% vs. 30%, P < 0.05) and this area of abrupt change was located within or at the edge of the SRD in 64% of eyes. Large choroidal vessels (pachyvessels) (82% located within the area of SRD) were always associated with the presence of SRD. An abrupt transition in choroidal thickness may be involved in the pathogenesis of SRD. In some cases, a radial scan pattern may better demonstrate mild SRD, choroidal contours and the focal choroidal variations than horizontal or vertical raster scan patterns.

  16. Ultrasound scan in the diagnosis of neonatal renal candidiasis

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Torres, D.; Berbel, O.; Andres, V.

    2003-01-01

    To describe the most pertinent echographic findings regarding systemic and renal candidiasis in high-risk neonates. Echographic findings and clinical histories of 40 neonates in the neonatal intensive care unit were retrospectively analyzed. Thirty-eight presented systemic candidiasis with renal participation, while two showed only renal candidiasis. Ultrasound scans were performed using 7.5 MHz probes. Alterations in renal echo structure, presence of echogenic material without acoustic shadowing in the excretory system (mycetoma), presence of lithiasis, pyonephrosis and associated renal malformations were all evaluated. Ten patients presented renal alterations in ultrasound scan. Six children had originally shown increased eye-catching in the renal parenchyma which was resolved after medical treatment. Four children presented renal mycetoma, and in two there were renal malformations. Both of these exhibited a profile for pyonephrosis. One patient with renal mycetoma without urological abnormalities developed a lithiasis. Surgical intervention was unnecessary in all cases. The most common echographic findings in immature high-risk low-weight patients with systemic and renal candidiasis were alterations in the eye-catching of renal parenchyma and the presence of mycetoma. (Author) 22 refs

  17. Eye movements of patients with tunnel vision while walking.

    Science.gov (United States)

    Vargas-Martín, Fernando; Peli, Eli

    2006-12-01

    To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head in patients walking in real environments. This information should help to define the visual field and clearance requirements for head-mounted mobility visual aids. Eye positions relative to the head were recorded in five patients with retinitis pigmentosa who had less than 15 degrees of visual field and in three normally sighted people, each walking in varied environments for more than 30 minutes. The eye-position recorder was made portable by modifying a head-mounted system (ISCAN, Burlington, MA). Custom data processing was implemented, to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. The patients with PFL exhibited narrower horizontal eye-position dispersions than did the normally sighted subjects (9.4 degrees vs. 14.2 degrees , P vision information. Their horizontal scanning was actually reduced, possibly because of lack of peripheral stimulation. The results suggest that a field of view as wide as 40 degrees may be needed for closed (immersive) head-mounted mobility aids, whereas a much narrower display, perhaps as narrow as 20 degrees , may be sufficient with an open design.

  18. Dry Eye

    Science.gov (United States)

    ... Eye » Facts About Dry Eye Listen Facts About Dry Eye Fact Sheet Blurb The National Eye Institute (NEI) ... and their families search for general information about dry eye. An eye care professional who has examined the ...

  19. A new scanning system for alpha decay events as calibration sources for range-energy relation in nuclear emulsion

    Science.gov (United States)

    Yoshida, J.; Kinbara, S.; Mishina, A.; Nakazawa, K.; Soe, M. K.; Theint, A. M. M.; Tint, K. T.

    2017-03-01

    A new scanning system named "Vertex picker" has been developed to rapid collect alpha decay events, which are calibration sources for the range-energy relation in nuclear emulsion. A computer-controlled optical microscope scans emulsion layers exhaustively, and a high-speed and high-resolution camera takes their micrographs. A dedicated image processing picks out vertex-like shapes. Practical operations of alpha decay search were demonstrated by emulsion sheets of the KEK-PS E373 experiment. Alpha decays of nearly 28 events were detected in eye-check work on a PC monitor per hour. This yield is nearly 20 times more effective than that by the conventional eye-scan method. The speed and quality is acceptable for the coming new experiment, J-PARC E07.

  20. A new scanning system for alpha decay events as calibration sources for range-energy relation in nuclear emulsion

    International Nuclear Information System (INIS)

    Yoshida, J.; Kinbara, S.; Mishina, A.; Nakazawa, K.; Soe, M.K.; Theint, A.M.M.; Tint, K.T.

    2017-01-01

    A new scanning system named “Vertex picker” has been developed to rapid collect alpha decay events, which are calibration sources for the range-energy relation in nuclear emulsion. A computer-controlled optical microscope scans emulsion layers exhaustively, and a high-speed and high-resolution camera takes their micrographs. A dedicated image processing picks out vertex-like shapes. Practical operations of alpha decay search were demonstrated by emulsion sheets of the KEK-PS E373 experiment. Alpha decays of nearly 28 events were detected in eye-check work on a PC monitor per hour. This yield is nearly 20 times more effective than that by the conventional eye-scan method. The speed and quality is acceptable for the coming new experiment, J-PARC E07.

  1. Radiation exposure distribution in patients undergoing CT brain scans

    International Nuclear Information System (INIS)

    Yang Zhanshan; Feng Dinghua; Chang Zichi; Li Shijun

    1989-12-01

    The distribution of surface exposures in patients undergoing single and multiple computerized tomographic brain scans with Hitachi CT-W500 was measured by LiF(Mg, Ti) thermoluminescent dosimetry. It was found that there was no significant difference in the sufrace exposures from different scanning slices. However, the exposure doses at different scanning angles around the head were different significantly. The reference point of the maximum surface exposure was at the temporal part of the head. the maximum surface exposure was at 1.65 x 10 -3 C·kg -1 while the average exposure was 1.55 x 10 -3 C·kg -1 . The ratio of the average dose resulting from nine scans to that from a single scan was 1.3, and the surface exposure contribution of scattered radiation was computed. At the same time the radiation doses to eyes, thyroid, chest and gonads of patiens at corresponding position were also measured and were compared with those from CT cranial scans in children and skull radiographic procedures respectively

  2. Visual Scanning Patterns during the Dimensional Change Card Sorting Task in Children with Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    Li Yi

    2012-01-01

    Full Text Available Impaired cognitive flexibility in children with autism spectrum disorder (ASD has been reported in previous literature. The present study explored ASD children’s visual scanning patterns during the Dimensional Change Card Sorting (DCCS task using eye-tracking technique. ASD and typical developing (TD children completed the standardized DCCS procedure on the computer while their eye movements were tracked. Behavioral results confirmed previous findings on ASD children’s deficits in executive function. ASD children’s visual scanning patterns also showed some specific underlying processes in the DCCS task compared to TD children. For example, ASD children looked shorter at the correct card in the postswitch phase and spent longer time at blank areas than TD children did. ASD children did not show a bias to the color dimension as TD children did. The correlations between the behavioral performance and eye moments were also discussed.

  3. Tumoral calcinoses in bone scanning: A case study

    International Nuclear Information System (INIS)

    Cook, P.

    1998-01-01

    Full text: Tumoral calcinosis (TC) is a rare disorder characterised by hyperphosphateamia, normocalceamia and calcified para-articular masses as seen on X-ray. At present, an inborn error of phosphorous metabolism is accepted as the primary cause. Symptoms include pain, swelling, infection and single- or multi-focal lesions. Radionuclide imaging was recently described as the most reliable and simplest method for detection, localisation and assessment of the calcific masses. Bone scintigraphy may demonstrate unsuspected masses even when clinical examination is negative. It is also useful in assessing the effects of surgery and therapy. A 55-year-old male with an 18-year history of TC presented to our department on two occasions. He was first referred to assess the extent of his calcinosis. He had known involvement of the hands, shoulders and pelvis, with little restriction of movement. He had a 6-8 year history of polio which was currently stable. Seven years later he again presented to our department, this time for the evaluation of a suspected fractured hip. On both occasions 800 MBq of 99 mTc-MDP was injected IV and whole body and planar images were obtained at three hours. In the second study, additional dynamic and blood pool images were obtained over the anterior aspect of both hips. Both scans were grossly abnormal and typical of the appearance of widespread TC or calcinosis universalis. Multiple areas of extra osseous uptake involving subcutaneous tissue and muscle of the hands, para-articular regions of both elbows, shoulders and hips were seen and confirmed by X-ray. Localised abnormalities were noted involving left lower neck, left forearm and left foot. Marked progression of the disease was seen in the region of the left shoulder on the second scan. No abnormalities were noted within the skeleton itself. Neither the dynamic nor blood pool phase of the study demonstrated significant hyperaemia in the region of the left proximal femur. Although the second

  4. Tumoral calcinoses in bone scanning: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Cook, P. [Royal Prince Alfred Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-03-01

    Full text: Tumoral calcinosis (TC) is a rare disorder characterised by hyperphosphateamia, normocalceamia and calcified para-articular masses as seen on X-ray. At present, an inborn error of phosphorous metabolism is accepted as the primary cause. Symptoms include pain, swelling, infection and single- or multi-focal lesions. Radionuclide imaging was recently described as the most reliable and simplest method for detection, localisation and assessment of the calcific masses. Bone scintigraphy may demonstrate unsuspected masses even when clinical examination is negative. It is also useful in assessing the effects of surgery and therapy. A 55-year-old male with an 18-year history of TC presented to our department on two occasions. He was first referred to assess the extent of his calcinosis. He had known involvement of the hands, shoulders and pelvis, with little restriction of movement. He had a 6-8 year history of polio which was currently stable. Seven years later he again presented to our department, this time for the evaluation of a suspected fractured hip. On both occasions 800 MBq of {sup 99}mTc-MDP was injected IV and whole body and planar images were obtained at three hours. In the second study, additional dynamic and blood pool images were obtained over the anterior aspect of both hips. Both scans were grossly abnormal and typical of the appearance of widespread TC or calcinosis universalis. Multiple areas of extra osseous uptake involving subcutaneous tissue and muscle of the hands, para-articular regions of both elbows, shoulders and hips were seen and confirmed by X-ray. Localised abnormalities were noted involving left lower neck, left forearm and left foot. Marked progression of the disease was seen in the region of the left shoulder on the second scan. No abnormalities were noted within the skeleton itself. Neither the dynamic nor blood pool phase of the study demonstrated significant hyperaemia in the region of the left proximal femur. Although the

  5. Arteriovenous Malformation in Temporal Lobe Presenting as Contralateral Ocular Symptoms Mimicking Carotid-Cavernous Fistula

    Directory of Open Access Journals (Sweden)

    Fadzillah Mohd-Tahir

    2013-01-01

    Full Text Available Aim. To report a rare case of arteriovenous malformation in temporal lobe presenting as contralateral orbital symptoms mimicking carotid-cavernous fistula. Method. Interventional case report. Results. A 31-year-old Malay gentleman presented with 2-month history of painful progressive exophthalmos of his left eye associated with recurrent headache, diplopia, and reduced vision. Ocular examination revealed congestive nonpulsating 7 mm exophthalmos of the left eye with no restriction of movements in all direction. There was diplopia in left lateral gaze. Left IOP was elevated at 29 mmHg. Left eye retinal vessels were slightly dilated and tortuous. CT scan was performed and showed right temporal arteriovenous malformation with a nidus of 3.8 cm × 2.5 cm with right middle cerebral artery as feeding artery. There was dilated left superior ophthalmic vein of 0.9 mm in diameter with enlarged left cavernous sinus. MRA and carotid angiogram confirmed right temporal arteriovenous malformation with no carotid-cavernous fistula. Most of the intracranial drainage was via left cavernous sinus. His signs and symptoms dramatically improved following successful embolisation, completely resolved after one year. Conclusion. Intracranial arteriovenous malformation is rarely presented with primary ocular presentation. Early intervention would salvage the eyes and prevent patients from more disaster morbidity or fatality commonly due to intracranial haemorrhage.

  6. Brain Activation Associated with Practiced Left Hand Mirror Writing

    Science.gov (United States)

    Kushnir, T.; Arzouan, Y.; Karni, A.; Manor, D.

    2013-01-01

    Mirror writing occurs in healthy children, in various pathologies and occasionally in healthy adults. There are only scant experimental data on the underlying brain processes. Eight, right-handed, healthy young adults were scanned (BOLD-fMRI) before and after practicing left-hand mirror-writing (lh-MW) over seven sessions. They wrote dictated…

  7. Dome-shaped macula: a compensatory mechanism in myopic anisometropia?

    Science.gov (United States)

    Keane, Pearse A; Mitra, Arijit; Khan, Imran J; Quhill, Fahd; Elsherbiny, Samer M

    2012-05-31

    The purpose of this article was to describe a patient with dome-shaped macula in the setting of mild myopic anisometropia and to speculate regarding the role of this feature as a compensatory mechanism in ocular development. The clinical records of a 49-year-old woman with this condition were reviewed. Spectral-domain optical coherence tomographic images revealed evidence of a dome-shaped macula. B-scan ultrasonography measured axial lengths of 23.8 mm in the right eye and 22.8 mm in the left eye. Spherical equivalents were -1.375 and +0.375 in the right and left eyes, respectively. Examination of the left eye was unremarkable. Dome-shaped macula has previously only been described in patients with high myopia. These findings support the hypothesis that myopic anisometropia, rather than absolute refractive status, is central to the development of dome-shaped macula and that this feature represents a protective mechanism aimed at reducing the effects of anisometropia. Copyright 2012, SLACK Incorporated.

  8. Lens subluxation after plasmin and SF6 injections in rabbit eyes.

    Directory of Open Access Journals (Sweden)

    Wei-Chi Wu

    Full Text Available To investigate the rate of lens subluxation following plasmin and/or SF6 injections in eyes, and whether a subsequent elevated level of vascular endothelial growth factor (VEGF and vitreous tap would aggravate subluxation.Four groups of rabbits were used. Group 1 received an intravitreal injection (IVI of plasmin and SF6 in the right eye; group 2 received an IVI of plasmin in the right eye; group 3 received an IVI of SF6 in the right eye; and group 4 received an IVI of balanced salt solution in the right eye. After treatment, IVIs of VEGF were given and vitreous tap was performed three times, followed by clinical observation of lens subluxation and scanning electronic microscope evaluation of the zonular fibers.After IVIs of plasmin and SF6, and VEGF and vitreous tap had been performed one to three times, lens subluxation was noted in 0%, 43%, 71%, 71%, and 86% of the eyes in group 1. After IVIs of plasmin, VEGF, and vitreous tap had been performed one to three times, lens subluxation was noted in 11%, 22%, 44%, 44%, and 67% of the eyes in group 2. The eyes in group 3 and 4 did not show signs of lens subluxation after VEGF IVIs and vitreous tap. Histology confirmed zonular fiber damage in the eyes treated with plasmin.The incidence of lens subluxation increased following plasmin injections in the eyes, and this was aggravated by the subsequent high VEGF level in the eyes and vitreous tapping. Zonular fibers were disrupted following plasmin treatment. These effects should be kept in mind when using plasmin enzymes in patients with vitreoretinal abnormalities.

  9. Eye tracking to explore attendance in health-state descriptions.

    Directory of Open Access Journals (Sweden)

    Anna Selivanova

    Full Text Available A crucial assumption in health valuation methods is that respondents pay equal attention to all information components presented in the response task. So far, there is no solid evidence that respondents are fulfilling this condition. The aim of our study is to explore the attendance to various information cues presented in the discrete choice (DC response tasks.Eye tracking was used to study the eye movements and fixations on specific information areas. This was done for seven DC response tasks comprising health-state descriptions. A sample of 10 respondents participated in the study. Videos of their eye movements were recorded and are presented graphically. Frequencies were computed for length of fixation and number of fixations, so differences in attendance were demonstrated for particular attributes in the tasks.All respondents completed the survey. Respondents were fixating on the left-sided health-state descriptions slightly longer than on the right-sided. Fatigue was not observed, as the time spent did not decrease in the final response tasks. The time spent on the tasks depended on the difficulty of the task and the amount of information presented.Eye tracking proved to be a feasible method to study the process of paying attention and fixating on health-state descriptions in the DC response tasks. Eye tracking facilitates the investigation of whether respondents fully read the information in health descriptions or whether they ignore particular elements.

  10. Driving with binocular visual field loss? A study on a supervised on-road parcours with simultaneous eye and head tracking.

    Directory of Open Access Journals (Sweden)

    Enkelejda Kasneci

    Full Text Available Post-chiasmal visual pathway lesions and glaucomatous optic neuropathy cause binocular visual field defects (VFDs that may critically interfere with quality of life and driving licensure. The aims of this study were (i to assess the on-road driving performance of patients suffering from binocular visual field loss using a dual-brake vehicle, and (ii to investigate the related compensatory mechanisms. A driving instructor, blinded to the participants' diagnosis, rated the driving performance (passed/failed of ten patients with homonymous visual field defects (HP, including four patients with right (HR and six patients with left homonymous visual field defects (HL, ten glaucoma patients (GP, and twenty age and gender-related ophthalmologically healthy control subjects (C during a 40-minute driving task on a pre-specified public on-road parcours. In order to investigate the subjects' visual exploration ability, eye movements were recorded by means of a mobile eye tracker. Two additional cameras were used to monitor the driving scene and record head and shoulder movements. Thus this study is novel as a quantitative assessment of eye movements and an additional evaluation of head and shoulder was performed. Six out of ten HP and four out of ten GP were rated as fit to drive by the driving instructor, despite their binocular visual field loss. Three out of 20 control subjects failed the on-road assessment. The extent of the visual field defect was of minor importance with regard to the driving performance. The site of the homonymous visual field defect (HVFD critically interfered with the driving ability: all failed HP subjects suffered from left homonymous visual field loss (HL due to right hemispheric lesions. Patients who failed the driving assessment had mainly difficulties with lane keeping and gap judgment ability. Patients who passed the test displayed different exploration patterns than those who failed. Patients who passed focused longer on

  11. Enucleaton of the right eye due to large choroidal melanoma with simultaneous penetrating cornea transplantation from OD to OS (Case report).

    OpenAIRE

    E. A. Korchuganova; A. Yu. Slonimskiy,; O. Yu. Yatsenko; M. Yu. Lerner

    2013-01-01

    There is presentation case report of 75‑year old woman with choroidal melanoma (T3N0M0) on the right eye and failed graft on the left pseudophakic eye with far advanced glaucoma and ARMD. No treatment was given to the leading eye with VA 0,2. VA of OS = 1 / ∞ pr.l.certa; PKP OS in 2008 for pseudophakic bullous keratopathy on the eye with far advanced glaucoma. IOP was normal after previous filtering surgery. After PKP VA = 0,04; clear graft during 2 years; then gradually opacification and vas...

  12. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    International Nuclear Information System (INIS)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-01-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens

  13. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Science.gov (United States)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-11-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  14. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Energy Technology Data Exchange (ETDEWEB)

    Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico); Reynoso-Mejía, Alberto [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F., Mexico and Departamento de Neuroimagen, Instituto Nacional de (Mexico); Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús [Departamento de Neuroimagen, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico)

    2014-11-07

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  15. Transient contribution of left posterior parietal cortex to cognitive restructuring.

    Science.gov (United States)

    Sutoh, Chihiro; Matsuzawa, Daisuke; Hirano, Yoshiyuki; Yamada, Makiko; Nagaoka, Sawako; Chakraborty, Sudesna; Ishii, Daisuke; Matsuda, Shingo; Tomizawa, Haruna; Ito, Hiroshi; Tsuji, Hiroshi; Obata, Takayuki; Shimizu, Eiji

    2015-03-17

    Cognitive restructuring is a fundamental method within cognitive behavioural therapy of changing dysfunctional beliefs into flexible beliefs and learning to react appropriately to the reality of an anxiety-causing situation. To clarify the neural mechanisms of cognitive restructuring, we designed a unique task that replicated psychotherapy during a brain scan. The brain activities of healthy male participants were analysed using functional magnetic resonance imaging. During the brain scan, participants underwent Socratic questioning aimed at cognitive restructuring regarding the necessity of handwashing after using the restroom. The behavioural result indicated that the Socratic questioning effectively decreased the participants' degree of belief (DOB) that they must wash their hands. Alterations in the DOB showed a positive correlation with activity in the left posterior parietal cortex (PPC) while the subject thought about and rated own belief. The involvement of the left PPC not only in planning and decision-making but also in conceptualization may play a pivotal role in cognitive restructuring.

  16. Regular Scanning Tunneling Microscope Tips can be Intrinsically Chiral

    International Nuclear Information System (INIS)

    Tierney, Heather L.; Murphy, Colin J.; Sykes, E. Charles H.

    2011-01-01

    We report our discovery that regular scanning tunneling microscope tips can themselves be chiral. This chirality leads to differences in electron tunneling efficiencies through left- and right-handed molecules, and, when using the tip to electrically excite molecular rotation, large differences in rotation rate were observed which correlated with molecular chirality. As scanning tunneling microscopy is a widely used technique, this result may have unforeseen consequences for the measurement of asymmetric surface phenomena in a variety of important fields.

  17. Regular scanning tunneling microscope tips can be intrinsically chiral.

    Science.gov (United States)

    Tierney, Heather L; Murphy, Colin J; Sykes, E Charles H

    2011-01-07

    We report our discovery that regular scanning tunneling microscope tips can themselves be chiral. This chirality leads to differences in electron tunneling efficiencies through left- and right-handed molecules, and, when using the tip to electrically excite molecular rotation, large differences in rotation rate were observed which correlated with molecular chirality. As scanning tunneling microscopy is a widely used technique, this result may have unforeseen consequences for the measurement of asymmetric surface phenomena in a variety of important fields.

  18. Lobster eye X-ray optics: Data processing from two 1D modules

    Science.gov (United States)

    Nentvich, O.; Urban, M.; Stehlikova, V.; Sieger, L.; Hudec, R.

    2017-07-01

    The X-ray imaging is usually done by Wolter I telescopes. They are suitable for imaging of a small part of the sky, not for all-sky monitoring. This monitoring could be done by a Lobster eye optics which can theoretically have a field of view up to 360 deg. All sky monitoring system enables a quick identification of source and its direction. This paper describes the possibility of using two independent one-dimensional Lobster Eye modules for this purpose instead of Wolter I and their post-processing into an 2D image. This arrangement allows scanning with less energy loss compared to Wolter I or two-dimensional Lobster Eye optics. It is most suitable especially for very weak sources.

  19. Occupational exposure to eye-lenses and extremities in interventional cardiology

    International Nuclear Information System (INIS)

    Jankowski, Jerzy; Brodecki, Marcin; Kosmider, Maciej; Tylkowski, Michal

    2008-01-01

    Full text: Despite of very fast developments in the field of Interventional Cardiology, the level of doses received by medical staff is still substantial and therefore must be routinely controlled. The annual dose limits established by International Commission on Radiological Protection are monitored by the personal dosimeters worn under the lead apron. In this method the information about doses on uncovered body parts can be only approximated. Values obtained by means of ring or wrist dosimetry are also insufficient to provide basis for conclusions on the extremities doses received by medical staff. The main purpose of this study was to investigate radiation doses absorbed for eye-lenses and extremities to personnel participating in cardiac procedures. The doses were measured using highly sensitive thermoluminescent dosimeters (LiF: Mg, Cu, P), calibrated in Secondary Standard Dosimetry Laboratory for X-ray beam typical of cardiac procedures. TLDs were placed in three locations: in a special band on eyebrow ridge, on a left ankle and on a left hand (finger's ring). Considerable amount of detectors used allowed determining the actual distribution of doses. Mean equivalent doses per procedure for Coronary Angiography (CAG) and Coronary Angiography with Percutaneous Transluminal Coronary Angioplasty (CAG+PTCA) were investigated. For CAG these values amounted to: on left eyebrow ridge from 80 μSv to 140 μSv, on right eyebrow ridge from 30 μSv to 75 μSv, on ankle from 80 μSv to 110 μSv and on hand from 190 μSv to 240 μSv, respectively. For CAG+PTCA the observed levels were: on left eyebrow ridge from 170 μSv to 240 μSv, on right eyebrow ridge from 60 μSv to 160 μSv, on ankle from 180 μSv to 270 μSv and on hand from 410 μSv to 590 μSv, respectively. The wild range of doses for both eyebrow ridges was especially visible and depend on operation position with respect to X-ray tube. The eye-lens doses will be measured using a Randoman anthropomorphic phantom

  20. Worms Expelled With the Urine From a Bosniak Cyst III of the Left Kidney.

    Science.gov (United States)

    Yang, Jie; Li, Pu; Su, Chuan; Zhang, Jia-Yi; Gu, Min

    2016-07-01

    An old fishman presented with left lumbago and finding worms in his urine. Type-B ultrasonic inspection and computed tomography scan found a Bosniak cyst III, containing several wire-like elements, in the middle of the left kidney. Expelled worms were confirmed to be Dioctophyma renale. After two courses of albendazole, the man was cured. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Using optical coherence tomography to evaluate glaucoma implant healing response in rabbit eyes

    Science.gov (United States)

    Gossage, Kirk W.; Tkaczyk, Tomasz S.; Barton, Jennifer K.

    2002-06-01

    Glaucoma is a set of diseases that cause optic nerve damage and visual field loss. The most important risk factor for the development of glaucoma is elevated intraocular pressure. One approach used to alleviate the pressure increase is to surgically install glaucoma implants. Two standard Ahmed and ten experimental ePTFE implants were evaluated in this study in rabbit eyes. The implants were imaged with optical coherence tomography (OCT) at 0, 7, 15, 30, and 90 days after implantation. Histology was collected at days 7, 15, 30, and 90 and compared to the OCT images. Preliminary analysis of images indicates that OCT can visualize the development of fibrous encapsulation of the implant, tissue erosion, fibrin accumulation in the implant tube, and tube position in the anterior chamber. A new OCT handheld probe was developed to facilitate in vivo imaging in rabbit eye studies. The OCT probe consists of a mechanical scaffold designed to allow the imaging fiber to be held in a fixed position with respect to the rabbit eye, with minimal anesthesia. A piezo electric lateral scanning device allows the imaging fiber to be scanned across the tissue so that 2D images may be acquired.

  2. A case study presentation: The MAG3 captopril renal scan, which side are you on ?

    International Nuclear Information System (INIS)

    Richards, A.

    1998-01-01

    Full text: A 68-year-old woman with widespread vascular disease presented to the Nuclear Medicine Department with severe hypertension, (a blood pressure of 200/160 supine), a known small right kidney, and a large abdominal aortic aneurysm. A baseline renal scan was performed with IV administration of 300 MBq of 99m Tc-labelled MAG3. A normal left kidney was demonstrated, with a Grade 0 renogram pattern. The right kidney was non visualised and non functioning. The patient was then administered orally with 25 mg of A.C.E. inhibitor captopril and her blood pressure fell by greater than 100 mm Hg. A second MAG3 Renal Scan was performed. The finding conflicted with results of a Renal Artery Angiogram and Renal Artery Doppler Ultrasound, both demonstrating a normal left renal artery. A repeat MAG3 Renal scan with captopril challenge was performed. Differential diagnosis included: 1.Left sided microvascular disease; 2. A functioning though very ischaemic right kidney that was producing renin, suggested by contrast opacification of the right renal cortex on CT; or 3. A false negative renal artery angiogram, with non-visualisation of an arterial stenosis caused by thrombus or compression of the left renal artery by the abdominal aortic aneurysm. Subsequent Renal Vein Renin Sampling measured left renal vein renin activity at 4.50,μg/L/h, (compared with 4.80μg/L/h in the IVC). Right renal vein renin activity was 13.20μg/L/h. This lateralization of renin secretion to the right side with suppression of left sided secretion suggested that the renovascular hypertension was caused by the right kidney. This was a very unusual result, as the MAG3 captopril renal scan had incorrectly and strongly suggested a left sided origin to the renovascular hypertension. In addition, the right kidney not seen to accumulate MAG3 was in fact functioning sufficiently to produce renin. It is hypothesized that the left kidney had adjusted to allow normal function only at very high circulating

  3. The eyes don't have it: lie detection and Neuro-Linguistic Programming.

    Directory of Open Access Journals (Sweden)

    Richard Wiseman

    Full Text Available Proponents of Neuro-Linguistic Programming (NLP claim that certain eye-movements are reliable indicators of lying. According to this notion, a person looking up to their right suggests a lie whereas looking up to their left is indicative of truth telling. Despite widespread belief in this claim, no previous research has examined its validity. In Study 1 the eye movements of participants who were lying or telling the truth were coded, but did not match the NLP patterning. In Study 2 one group of participants were told about the NLP eye-movement hypothesis whilst a second control group were not. Both groups then undertook a lie detection test. No significant differences emerged between the two groups. Study 3 involved coding the eye movements of both liars and truth tellers taking part in high profile press conferences. Once again, no significant differences were discovered. Taken together the results of the three studies fail to support the claims of NLP. The theoretical and practical implications of these findings are discussed.

  4. Left neglected, but only in far space: Spatial biases in healthy participants revealed in a visually-guided grasping task

    Directory of Open Access Journals (Sweden)

    Natalie ede Bruin

    2014-01-01

    Full Text Available Hemispatial neglect is a common outcome of stroke that is characterised by the inability to orient towards, and attend to stimuli in contralesional space. It is established that hemispatial neglect has a perceptual component, however, the presence and severity of motor impairments is controversial. Establishing the nature of space use and spatial biases during visually-guided actions amongst healthy individuals is critical to understanding the presence of visuomotor deficits in patients with neglect. Accordingly, three experiments were conducted to investigate the effect of object spatial location on patterns of grasping. Experiment 1 required right-handed participants to reach and grasp for blocks in order to construct 3D models. The blocks were scattered on a tabletop divided into equal size quadrants: left near, left far, right near, and right far. Identical sets of building blocks were available in each quadrant. Space use was dynamic, with participants initially grasping blocks from right near space and tending to ‘neglect’ left far space until the final stages of the task. Experiment 2 repeated the protocol with left-handed participants. Remarkably, left-handed participants displayed a similar pattern of space use to right-handed participants. In Experiment 3 eye movements were examined to investigate whether ‘neglect’ for grasping in left far reachable space had its origins in attentional biases. It was found that patterns of eye movements mirrored patterns of reach-to-grasp movements. We conclude that there are spatial biases during visually-guided grasping, specifically, a tendency to neglect left far reachable space, and that this ‘neglect’ is attentional in origin. The results raise the possibility that visuomotor impairments reported among patients with right hemisphere lesions when working in contralesional space may result in part from this inherent tendency to ‘neglect’ left far space irrespective of the presence

  5. Phase image characterization of ventricular contraction in left anterior hemiblock

    International Nuclear Information System (INIS)

    Ono, Akifumi; Mizuno, Haruyoshi; Tahara, Yorio; Ishikawa, Kyozo

    1991-01-01

    We investigated whether or not left anterior hemiblock is present in patients with left axis deviation using first-harmonic Fourier analysis of gated blood-pool images. Gated blood-pool images were taken in 50 patients without contraction abnormality. They included 14 normal subjects, 8 patients with right bundle branch block (RBBB), 20 with left axis deviation (LAD) and 8 with both RBBB and LAD (RBBB+LAD). ECG gated blood-pool scans were acquired in the anterior and 'best septal' left anterior oblique projections. First, the phase images were displayed cinematically as a continuous-loop movie. Next, for quantitative analysis of the phase image, the whole left ventricular and left ventricular high lateral regions of interest were drawn. The 'regional phase shift' (RPS) was then defined as {RPS=A-a} where 'A' is the mean value of the whole left ventricular phase angles and 'a' is that of phase angles in the high lateral region. The left ventricular phase changes and the RPSs in the RBBB and LAD groups were similar to those in the normal group. In the RBBB+LAD group, the latest phase changes occurred in the high anterolateral region. The RPSs of this group were significantly lower than those in the other 3 groups (p<0.01). These data suggest that left anterior hemiblock might coexist with RBBB in patients with RBBB+LAD, whereas left anterior hemiblock might not exist in the majority of patients with LAD alone. (author)

  6. An unusual case of a serious blunt injury of the eye

    Directory of Open Access Journals (Sweden)

    Jovanović Miloš

    2009-01-01

    Full Text Available Introduction. Optic nerve avulsion is a serious injury of the eye. The objective of the paper was to present the peculiarity of the eye injury caused by a penetrating orbital wound with foreign body being retained in the orbit. Case report. A 15-year-old boy who sustained injury by chain link is presented. While he was turning the chain round in his hand, the last link broke off, piercing the lower lid, penetrated the left orbital cavity and remained behind the eyeball at the top of orbit. While passing towards the top of the orbit, the foreign body caused a blunt injury of the eyeball and avulsion of the ocular nerve. The accurate localization of the foreign body was verified by X-ray and CT imaging. The foreign body was removed through the entry wound. The eye injury resulted in amaurosis. Conclusion. This injury was one of those that could have been prevented.

  7. Both lexical and non-lexical characters are processed during saccadic eye movements.

    Directory of Open Access Journals (Sweden)

    Hao Zhang

    Full Text Available On average our eyes make 3-5 saccadic movements per second when we read, although their neural mechanism is still unclear. It is generally thought that saccades help redirect the retinal fovea to specific characters and words but that actual discrimination of information only occurs during periods of fixation. Indeed, it has been proposed that there is active and selective suppression of information processing during saccades to avoid experience of blurring due to the high-speed movement. Here, using a paradigm where a string of either lexical (Chinese or non-lexical (alphabetic characters are triggered by saccadic eye movements, we show that subjects can discriminate both while making saccadic eye movement. Moreover, discrimination accuracy is significantly better for characters scanned during the saccadic movement to a fixation point than those not scanned beyond it. Our results showed that character information can be processed during the saccade, therefore saccades during reading not only function to redirect the fovea to fixate the next character or word but allow pre-processing of information from the ones adjacent to the fixation locations to help target the next most salient one. In this way saccades can not only promote continuity in reading words but also actively facilitate reading comprehension.

  8. Clinical observation of one time short-pulse pattern scan laser pan-retinal photocoagulation for proliferative diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2016-04-01

    Full Text Available AIM: To investigate the clinical efficacy and benefit of short-pulse pattern scan laser(PASCALphotocoagulation for proliferative diabetic retinopathy(PDR.METHODS:Twenty-eight PDR patients(42 eyesunderwent short-pulse PASCAL pan-retinal photocoagulation(PRPwere analyzed.The best corrected visual acuity was ≥0.1 in 36 eyes, RESULTS: All the cases had no pain during the short-pulse PASCAL treatment.One year after treatments,the final visual acuity was improved in 6 eyes,kept stable in 28 eyes and decreased in 8 eyes; neovascularization were regressed in 18 eyes(43%, stable in 12 eyes(29%, uncontrolled in 12 eyes(29%. Five eyes(12%received vitrectomy due to vitreous hemorrhage.Compared with before operation, retina thickness in central fovea of macula and visual field had no obvious change after one-time PASCAL PRP(P>0.05. CONCLUSION:The one-time short-pulse PASCAL PRP could stabilize the progress of PDR safely, effectively and simply.

  9. Improving left spatial neglect through music scale playing.

    Science.gov (United States)

    Bernardi, Nicolò Francesco; Cioffi, Maria Cristina; Ronchi, Roberta; Maravita, Angelo; Bricolo, Emanuela; Zigiotto, Luca; Perucca, Laura; Vallar, Giuseppe

    2017-03-01

    The study assessed whether the auditory reference provided by a music scale could improve spatial exploration of a standard musical instrument keyboard in right-brain-damaged patients with left spatial neglect. As performing music scales involves the production of predictable successive pitches, the expectation of the subsequent note may facilitate patients to explore a larger extension of space in the left affected side, during the production of music scales from right to left. Eleven right-brain-damaged stroke patients with left spatial neglect, 12 patients without neglect, and 12 age-matched healthy participants played descending scales on a music keyboard. In a counterbalanced design, the participants' exploratory performance was assessed while producing scales in three feedback conditions: With congruent sound, no-sound, or random sound feedback provided by the keyboard. The number of keys played and the timing of key press were recorded. Spatial exploration by patients with left neglect was superior with congruent sound feedback, compared to both Silence and Random sound conditions. Both the congruent and incongruent sound conditions were associated with a greater deceleration in all groups. The frame provided by the music scale improves exploration of the left side of space, contralateral to the right hemisphere, damaged in patients with left neglect. Performing a scale with congruent sounds may trigger at some extent preserved auditory and spatial multisensory representations of successive sounds, thus influencing the time course of space scanning, and ultimately resulting in a more extensive spatial exploration. These findings offer new perspectives also for the rehabilitation of the disorder. © 2015 The British Psychological Society.

  10. [Left lateral gaze paresis due to subcortical hematoma in the right precentral gyrus].

    Science.gov (United States)

    Sato, K; Takamori, M

    1998-03-01

    We report a case of transient left lateral gaze paresis due to a hemorrhagic lesion restricted in the right precentral gyrus. A 74-year-old female experienced a sudden clumsiness of the left upper extremity. A neurological examination revealed a left central facial paresis, distal dominant muscle weakness in the left upper limb and left lateral gaze paresis. There were no other focal neurological signs. Laboratory data were all normal. Brain CTs and MRIs demonstrated a subcortical hematoma in the right precentral gyrus. The neurological symptoms and signs disappeared over seven days. A recent physiological study suggested that the human frontal eye field (FEF) is located in the posterior part of the middle frontal gyrus (Brodmann's area 8) and the precentral gyrus around the precentral sulcus. More recent studies stressed the role of the precentral sulcus and the precentral gyrus. Our case supports those physiological findings. The hematoma affected both the FEF and its underlying white matter in our case. We assume the lateral gaze paresis is attributable to the disruption of the fibers from the FEF. It is likely that fibers for motor control of the face, upper extremity, and lateral gaze lie adjacently in the subcortical area.

  11. Fluid mechanics of blood flow in human fetal left ventricles based on patient-specific 4D ultrasound scans.

    Science.gov (United States)

    Lai, Chang Quan; Lim, Guat Ling; Jamil, Muhammad; Mattar, Citra Nurfarah Zaini; Biswas, Arijit; Yap, Choon Hwai

    2016-10-01

    The mechanics of intracardiac blood flow and the epigenetic influence it exerts over the heart function have been the subjects of intense research lately. Fetal intracardiac flows are especially useful for gaining insights into the development of congenital heart diseases, but have not received due attention thus far, most likely because of technical difficulties in collecting sufficient intracardiac flow data in a safe manner. Here, we circumvent such obstacles by employing 4D STIC ultrasound scans to quantify the fetal heart motion in three normal 20-week fetuses, subsequently performing 3D computational fluid dynamics simulations on the left ventricles based on these patient-specific heart movements. Analysis of the simulation results shows that there are significant differences between fetal and adult ventricular blood flows which arise because of dissimilar heart morphology, E/A ratio, diastolic-systolic duration ratio, and heart rate. The formations of ventricular vortex rings were observed for both E- and A-wave in the flow simulations. These vortices had sufficient momentum to last until the end of diastole and were responsible for generating significant wall shear stresses on the myocardial endothelium, as well as helicity in systolic outflow. Based on findings from previous studies, we hypothesized that these vortex-induced flow properties play an important role in sustaining the efficiency of diastolic filling, systolic pumping, and cardiovascular flow in normal fetal hearts.

  12. Eleven episodes of recurrent optic neuritis of the same eye for 22 years eventually diagnosed as neuromyelitis optica spectrum disorder.

    Science.gov (United States)

    Yew, Yih Chian; Hor, Jyh Yung; Lim, Thien Thien; Kanesalingam, Ruban; Ching, Yee Ming; Arip, Masita; Easaw, P E Samuel; Eow, Gaik Bee

    2016-11-01

    It is difficult to predict whether a particular attack of neuromyelitis optica spectrum disorder (NMOSD) will affect the optic nerve [optic neuritis (ON): unilateral or bilateral], spinal cord (myelitis), brain or brainstem, or a combination of the above. We report an interesting case of recurrent ON of the same eye for a total of 11 episodes in a Chinese woman. Over a period of 22 years, the attacks only involved the left eye, and never the right eye and also no myelitis. For a prolonged duration, she was diagnosed as recurrent idiopathic ON. Only until she was tested positive for aquaporin 4 antibody that her diagnosis was revised to NMOSD. Optical coherence tomography revealed thinning of the retinal nerve fibre layer (RNFL) for the affected left eye, while the RNFL thickness was within normal range for the unaffected right eye. The disability accrual in NMOSD is generally considered to be attack-related - without a clinical attack of ON, there shall be no visual impairment, and no significant subclinical thinning of RNFL. Our case is in agreement with this notion. This is in contrast to multiple sclerosis where subclinical RNFL thinning does occur. This case highlights the importance of revisiting and questioning a diagnosis of recurrent idiopathic ON particularly when new diagnostic tools are available. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. MR-eyetracker: a new method for eye movement recording in functional magnetic resonance imaging.

    Science.gov (United States)

    Kimmig, H; Greenlee, M W; Huethe, F; Mergner, T

    1999-06-01

    We present a method for recording saccadic and pursuit eye movements in the magnetic resonance tomograph designed for visual functional magnetic resonance imaging (fMRI) experiments. To reliably classify brain areas as pursuit or saccade related it is important to carefully measure the actual eye movements. For this purpose, infrared light, created outside the scanner by light-emitting diodes (LEDs), is guided via optic fibers into the head coil and onto the eye of the subject. Two additional fiber optical cables pick up the light reflected by the iris. The illuminating and detecting cables are mounted in a plastic eyepiece that is manually lowered to the level of the eye. By means of differential amplification, we obtain a signal that covaries with the horizontal position of the eye. Calibration of eye position within the scanner yields an estimate of eye position with a resolution of 0.2 degrees at a sampling rate of 1000 Hz. Experiments are presented that employ echoplanar imaging with 12 image planes through visual, parietal and frontal cortex while subjects performed saccadic and pursuit eye movements. The distribution of BOLD (blood oxygen level dependent) responses is shown to depend on the type of eye movement performed. Our method yields high temporal and spatial resolution of the horizontal component of eye movements during fMRI scanning. Since the signal is purely optical, there is no interaction between the eye movement signals and the echoplanar images. This reasonably priced eye tracker can be used to control eye position and monitor eye movements during fMRI.

  14. Is ultrasonography essential before surgery in eyes with advanced cataracts?

    Directory of Open Access Journals (Sweden)

    Salman Amjad

    2006-01-01

    Full Text Available Background: Ultrasonography is an important tool for evaluating the posterior segment in eyes with opaque media. Aim: To study the incidence of posterior segment pathology in eyes with advanced cataract and to see whether certain features could be used as predictors for an abnormal posterior segment on ultrasound. Setting: Tertiary care hospital in South India. Methods and Materials: In this prospective study conducted over a 6-month period, all eyes with dense cataracts precluding visualization of fundus underwent assessment with ultrasound. Presence of certain patient and ocular "risk" factors believed to be associated with a higher incidence of abnormal posterior segment on ultrasound were looked for and the odds ratio (OR for posterior segment pathology in these eyes was calculated. Results: Of the 418 eyes assessed, 36 eyes (8.6% had evidence of posterior segment pathology on ultrasound. Retinal detachment (17 eyes; 4.1% was the most frequent abnormality detected. Among patient features, diabetes mellitus (OR= 4.9, P=0.003 and age below 50 years (OR= 15.4, P=0.001 were associated with a high incidence of abnormal ultrasound scans. In ocular features, posterior synechiae (OR= 20.2, P=0.000, iris coloboma (OR= 34.6, P=0.000, inaccurate projection of rays (OR= 15.1, P=0.002, elevated intraocular pressure (OR= 15.1, P=0.004, and keratic precipitates (OR= 22.4, P=0.004 were associated with high incidence of posterior segment pathology. Only four eyes (1.5% without these features had abnormal posterior segment on ultrasonography. Conclusions: Certain patient and ocular features are indicative of a high risk for posterior segment pathology and such patients should be evaluated by ultrasonography prior to cataract surgery. In the absence of these risk factors, the likelihood of detecting abnormalities on preoperative ultrasonography in eyes with advanced cataracts is miniscule.

  15. Analysis of the Origin of Atypical Scanning Laser Polarimetry Patterns by Polarization-Sensitive Optical Coherence Tomography

    Science.gov (United States)

    Götzinger, Erich; Pircher, Michael; Baumann, Bernhard; Hirn, Cornelia; Vass, Clemens; Hitzenberger, Christoph K.

    2010-01-01

    Purpose To analyze the physical origin of atypical scanning laser polarimetry (SLP) patterns. To compare polarization-sensitive optical coherence tomography (PS-OCT) scans to SLP images. To present a method to obtain pseudo-SLP images by PS-OCT that are free of atypical artifacts. Methods Forty-one eyes of healthy subjects, subjects with suspected glaucoma, and patients with glaucoma were imaged by SLP (GDx VCC) and a prototype spectral domain PS-OCT system. The PS-OCT system acquires three-dimensional (3D) datasets of intensity, retardation, and optic axis orientation simultaneously within 3 seconds. B-scans of intensity and retardation and en face maps of retinal nerve fiber layer (RNFL) retardation were derived from the 3D PS-OCT datasets. Results were compared with those obtained by SLP. Results Twenty-two eyes showed atypical retardation patterns, and 19 eyes showed normal patterns. From the 22 atypical eyes, 15 showed atypical patterns in both imaging modalities, five were atypical only in SLP images, and two were atypical only in PS-OCT images. In most (15 of 22) atypical cases, an increased penetration of the probing beam into the birefringent sclera was identified as the source of atypical patterns. In such cases, the artifacts could be eliminated in PS-OCT images by depth segmentation and exclusion of scleral signals. Conclusions PS-OCT provides deeper insight into the contribution of different fundus layers to SLP images. Increased light penetration into the sclera can distort SLP retardation patterns of the RNFL. PMID:19036999

  16. Two- and three-dimensional topographic analysis of pathologically myopic eyes with dome-shaped macula and inferior staphyloma by spectral domain optical coherence tomography.

    Science.gov (United States)

    García-Ben, Antonio; Kamal-Salah, Radua; García-Basterra, Ignacio; Gonzalez Gómez, Ana; Morillo Sanchez, María José; García-Campos, Jose Manuel

    2017-05-01

    To investigate the posterior anatomical structure of pathologically myopic eyes with dome-shaped macula and inferior staphyloma using spectral domain optical coherence tomography (SD-OCT). Our database of 260 pathologically myopic eyes was analyzed retrospectively to identify patients with dome-shaped macula and inferior staphyloma. All patients underwent vertical and horizontal SD-OCT scans across the central fovea, with three-dimensional macular map reconstruction. Best-corrected visual acuity, axial length, and choroidal thickness measurements were recorded. The macular bulge height was also analyzed in eyes with dome-shaped macula. In the three-dimensional images, the symmetry and orientation of the main plane of the inward incurvation of the macula were examined. Twenty-eight (10.7%) of the 260 pathologically myopic eyes had dome-shaped macula of one of three different types: a round radially symmetrical dome (eight eyes, 28.5%), a horizontal axially symmetrical oval-shaped dome (15 eyes, 53.5%), or a vertical axially symmetrical oval-shaped dome (five eyes, 17.8%). The macular bulge height was significantly greater in horizontal oval-shaped dome eyes (p = 0.01, for each comparison). Inferior posterior staphylomas were observed in ten (3.8%) of the 260 pathologically myopic eyes with asymmetrical macular bends. Vertical and horizontal OCT sectional scanning in combination with three-dimensional macular map reconstruction provides important information for understanding the posterior anatomical structure of dome-shaped macula and inferior staphyloma in pathologically myopic eyes.

  17. SU-F-T-51: Investigating the Effect of Eye Size and Eccentricity On Normal Tissue Doses From Eye Plaque Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Polsdofer, E; Crilly, R [Oregon Health & Science University Portland, OR (United States)

    2016-06-15

    Purpose: This study investigates the effect of eye size and eccentricity on doses to critical tissues by simulating doses in the Plaque Simulator (v. 6.3.1) software. Present OHSU plaque brachytherapy treatment focuses on delivering radiation to the tumor measured with ocular ultrasound plus a small margin and assumes the orbit has the dimensions of a “standard eye.” Accurately modeling the dimensions of the orbit requires a high resolution ocular CT. This study quantifies how standard differences in equatorial diameters and eccentricity affect calculated doses to critical structures in order to query the justification of the additional CT scan to the treatment planning process. Methods: Tumors of 10 mm × 10 mm × 5 mm were modeled at the 12:00:00 hour with a latitude of 45 degrees. Right eyes were modeled at a number of equatorial diameters from 17.5 to 28 mm for each of the standard non-notched COMS plaques with silastic inserts. The COMS plaques were fully loaded with uniform activity, centered on the tumor, and prescribed to a common tumor dose (85 Gy/100 hours). Variations in the calculated doses to normal structures were examined to see if the changes were significant. Results: The calculated dose to normal structures show a marked dependence on eye geometry. This is exemplified by fovea dose which more than doubled in the smaller eyes and nearly halved in the larger model. Additional significant dependence was found in plaque size on the calculated dose in spite of all plaques giving the same dose to the prescription point. Conclusion: The variation in dose with eye dimension fully justifies the addition of a high resolution ocular CT to the planning technique. Additional attention must be made to plaque size beyond simply covering the tumor when considering normal tissue dose.

  18. Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy

    Science.gov (United States)

    Hunter, Jennifer J.; Masella, Benjamin; Dubra, Alfredo; Sharma, Robin; Yin, Lu; Merigan, William H.; Palczewska, Grazyna; Palczewski, Krzysztof; Williams, David R.

    2011-01-01

    In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images of the macaque cone mosaic were obtained using a fluorescence adaptive optics scanning laser ophthalmoscope, overcoming the challenges of a low numerical aperture, imperfect optics of the eye, high required light levels, and eye motion. Although the specific fluorophores are as yet unknown, strong in vivo intrinsic fluorescence allowed images of the cone mosaic. Imaging intact ex vivo retina revealed that the strongest two-photon excited fluorescence signal comes from the cone inner segments. The fluorescence response increased following light stimulation, which could provide a functional measure of the effects of light on photoreceptors. PMID:21326644

  19. "Far from the heart far from the eye": evidence from the Capgras delusion.

    Science.gov (United States)

    Brighetti, Gianni; Bonifacci, Paola; Borlimi, Rosita; Ottaviani, Cristina

    2007-05-01

    Capgras syndrome is characterised by the belief that a significant other has been replaced by an identical-looking impostor. These patients have no difficulties with visual recognition but fail to show a skin conductance response (SCR) to the objects of the delusion. A case of Capgras delusion (YY), specifically characterised by the absence of brain lesions, constituted a good opportunity to test the relationship between SCR hyporesponsiveness and eye movement patterns to familiar and unfamiliar faces. Visual scan path and SCR were recorded for YY and 8 controls during the presentation of family members' photographs matched with unfamiliar faces of the same sex, age, and physical likeness. Eye movement patterns were explored by selecting three specific areas of interest (AOI) involving the eyes, the mouth, and the face regions. In contrast with controls, YY showed a reduction in number and sum of fixation durations to the eyes (p.05) to familiar vs. nonfamiliar faces. SCR and fixation duration to family members' eyes were significantly correlated (r=.77) in both YY and controls. Eye region exploration seems to be related to the autonomic reactivity elicited by the affective valence of familiar faces.

  20. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension

    International Nuclear Information System (INIS)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya; Fukutake, Toshio.

    1982-01-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH 2 O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH 2 O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered. (author)

  1. Acute contained ruptured aortic aneurysm presenting as left vocal fold immobility.

    Science.gov (United States)

    Gnagi, Sharon H; Howard, Brittany E; Hoxworth, Joseph M; Lott, David G

    2015-01-01

    Objective. To recognize intrathoracic abnormalities, including expansion or rupture of aortic aneurysms, as a source of acute onset vocal fold immobility. Methods. A case report and review of the literature. Results. An 85-year-old female with prior history of an aortic aneurysm presented to a tertiary care facility with sudden onset hoarseness. On laryngoscopy, the left vocal fold was immobile in the paramedian position. A CT scan obtained that day revealed a new, large hematoma surrounding the upper descending aortic stent graft consistent with an acute contained ruptured aortic aneurysm. She was referred to the emergency department for evaluation and treatment by vascular surgery. She was counseled regarding surgical options and ultimately decided not to pursue further treatment. Her vocal fold immobility was subsequently treated via office-based injection medialization two weeks after presentation and again 5 months after the initial injection which dramatically improved her voice. Follow-up CT scan at 8 months demonstrated a reduction of the hematoma. The left vocal cord remains immobile to date. Conclusion. Ortner's syndrome, or cardiovocal syndrome, is hoarseness secondary to left recurrent laryngeal nerve palsy caused by cardiovascular pathology. It is a rare condition and, while typically presenting gradually, may also present with acute symptomatology.

  2. Acute Contained Ruptured Aortic Aneurysm Presenting as Left Vocal Fold Immobility

    Directory of Open Access Journals (Sweden)

    Sharon H. Gnagi

    2015-01-01

    Full Text Available Objective. To recognize intrathoracic abnormalities, including expansion or rupture of aortic aneurysms, as a source of acute onset vocal fold immobility. Methods. A case report and review of the literature. Results. An 85-year-old female with prior history of an aortic aneurysm presented to a tertiary care facility with sudden onset hoarseness. On laryngoscopy, the left vocal fold was immobile in the paramedian position. A CT scan obtained that day revealed a new, large hematoma surrounding the upper descending aortic stent graft consistent with an acute contained ruptured aortic aneurysm. She was referred to the emergency department for evaluation and treatment by vascular surgery. She was counseled regarding surgical options and ultimately decided not to pursue further treatment. Her vocal fold immobility was subsequently treated via office-based injection medialization two weeks after presentation and again 5 months after the initial injection which dramatically improved her voice. Follow-up CT scan at 8 months demonstrated a reduction of the hematoma. The left vocal cord remains immobile to date. Conclusion. Ortner’s syndrome, or cardiovocal syndrome, is hoarseness secondary to left recurrent laryngeal nerve palsy caused by cardiovascular pathology. It is a rare condition and, while typically presenting gradually, may also present with acute symptomatology.

  3. Does consolidation of visuospatial sequence knowledge depend on eye movements?

    Directory of Open Access Journals (Sweden)

    Daphné Coomans

    Full Text Available In the current study, we assessed whether visuospatial sequence knowledge is retained over 24 hours and whether this retention is dependent on the occurrence of eye movements. Participants performed two sessions of a serial reaction time (SRT task in which they had to manually react to the identity of a target letter pair presented in one of four locations around a fixation cross. When the letter pair 'XO' was presented, a left response had to be given, when the letter pair 'OX' was presented, a right response was required. In the Eye Movements (EM condition, eye movements were necessary to perform the task since the fixation cross and the target were separated by at least 9° visual angle. In the No Eye Movements (NEM condition, on the other hand, eye movements were minimized by keeping the distance from the fixation cross to the target below 1° visual angle and by limiting the stimulus presentation to 100 ms. Since the target identity changed randomly in both conditions, no manual response sequence was present in the task. However, target location was structured according to a deterministic sequence in both the EM and NEM condition. Learning of the target location sequence was determined at the end of the first session and 24 hours after initial learning. Results indicated that the sequence learning effect in the SRT task diminished, yet remained significant, over the 24 hour interval in both conditions. Importantly, the difference in eye movements had no impact on the transfer of sequence knowledge. These results suggest that the retention of visuospatial sequence knowledge occurs alike, irrespective of whether this knowledge is supported by eye movements or not.

  4. The cortical eye proprioceptive signal modulates neural activity in higher-order visual cortex as predicted by the variation in visual sensitivity

    DEFF Research Database (Denmark)

    Balslev, Daniela; Siebner, Hartwig R; Paulson, Olaf B

    2012-01-01

    target when the right eye was rotated leftwards as compared with when it was rotated rightwards. This effect was larger after S1(EYE)-rTMS than after rTMS of a control area in the motor cortex. The neural response to retinally identical stimuli in this area could be predicted from the changes in visual......Whereas the links between eye movements and the shifts in visual attention are well established, less is known about how eye position affects the prioritization of visual space. It was recently observed that visual sensitivity varies with the direction of gaze and the level of excitability...... in the eye proprioceptive representation in human left somatosensory cortex (S1(EYE)), so that after 1Hz repetitive transcranial magnetic stimulation (rTMS) over S1(EYE), targets presented nearer the center of the orbit are detected more accurately. Here we used whole-brain functional magnetic resonance...

  5. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  6. Validation of geometric measurements of the left atrium and pulmonary veins for analysis of reverse structural remodeling following ablation therapy

    Science.gov (United States)

    Rettmann, M. E.; Holmes, D. R., III; Gunawan, M. S.; Ge, X.; Karwoski, R. A.; Breen, J. F.; Packer, D. L.; Robb, R. A.

    2012-03-01

    Geometric analysis of the left atrium and pulmonary veins is important for studying reverse structural remodeling following cardiac ablation therapy. It has been shown that the left atrium decreases in volume and the pulmonary vein ostia decrease in diameter following ablation therapy. Most analysis techniques, however, require laborious manual tracing of image cross-sections. Pulmonary vein diameters are typically measured at the junction between the left atrium and pulmonary veins, called the pulmonary vein ostia, with manually drawn lines on volume renderings or on image cross-sections. In this work, we describe a technique for making semi-automatic measurements of the left atrium and pulmonary vein ostial diameters from high resolution CT scans and multi-phase datasets. The left atrium and pulmonary veins are segmented from a CT volume using a 3D volume approach and cut planes are interactively positioned to separate the pulmonary veins from the body of the left atrium. The cut plane is also used to compute the pulmonary vein ostial diameter. Validation experiments are presented which demonstrate the ability to repeatedly measure left atrial volume and pulmonary vein diameters from high resolution CT scans, as well as the feasibility of this approach for analyzing dynamic, multi-phase datasets. In the high resolution CT scans the left atrial volume measurements show high repeatability with approximately 4% intra-rater repeatability and 8% inter-rater repeatability. Intra- and inter-rater repeatability for pulmonary vein diameter measurements range from approximately 2 to 4 mm. For the multi-phase CT datasets, differences in left atrial volumes between a standard slice-by-slice approach and the proposed 3D volume approach are small, with percent differences on the order of 3% to 6%.

  7. Diabetes eye exams

    Science.gov (United States)

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... if the doctor who takes care of your diabetes checks your eyes, you need an eye exam ...

  8. Cerebral blood flow SPECT scanning in cortico-basal degeneration

    International Nuclear Information System (INIS)

    Slawek, J.; Walczak, A.; Krupa-Olchawa, J.; Lass, P.; Dubaniewicz, M.

    1999-01-01

    Idiopathic Parkinson's disease accounts for ca. 75% of all cases of Parkinsonism. Corticobasal degeneration is a relatively rare example of the so-called ''Parkinson-plus'' syndrome. The authors present the case of a 56-year-old woman with rigidity and atypical tremor of upper extremity followed by gait apraxia, dysarthria, bilateral pyramidal signs and myoclonus. There was no improvement after treatment with L-dopa. The disease has progressed, but the patient is still alive. On the basis of clinical data a diagnosis of corticobasal degeneration has been established. Cerebral blood flow SPECT scanning revealed diffuse hypoperfusion of left frontal lobe, antero-inferior part of the left temporal lobe and left basal ganglia. The case illustrates the usefulness of brain SPECT in atypical forma of Parkinson's disease. (author)

  9. Changes in the ionic and protein contents of adult Schistocerca Gregaria compound eyes due to He-Ne laser exposure

    International Nuclear Information System (INIS)

    El-Gindi, A.M.; Osiris, W.G.; El-kes, N.; Abd El-Meguid, A.

    1996-01-01

    The induced change in the concentration of the ionic content such as Na, K, and Ca in the compound eyes of Schistocerca Gregaria was carried out before and after exposure for different periodic times to He-Ne ;laser beam. Total protein and albumin contents in the compound eyes were also determined. The Data indicated that the ionic contents (Na, K and Ca) showed acceptable and significant changes in both the right (R) and left (L) eyes after exposure to different periodic times up to 60 minutes in comparison with the control ones. Moreover, very high significant increase in the total protein content (about 70.2%) as well as significant decrease in the albumin content (about 39.1%) in the right (R) eyes after exposure to He-Ne laser beam for 30 minutes in comparison with the control (unexposed) eyes, were detected. 2 tabs

  10. Localization of coronary artery disease with exercise electrocardiography: correlation with thallium-201 myocardial perfusion scanning

    International Nuclear Information System (INIS)

    Dunn, R.F.; Freedman, B.; Bailey, I.K.; Uren, R.F.; Kelly, D.T.

    1981-01-01

    In 61 patients with single vessel coronary artery disease (70 percent or greater obstruction of luminal diameter in only one vessel) and no previous myocardial infarction, the sites of ischemic changes on 12 lead exercise electrocardiography and on thallium-201 myocardial perfusion scanning were related to the obstructed coronary artery. The site of exercise-induced S-T segment depression did not identify which coronary artery was obstructed. In the 37 patients with left anterior descending coronary artery disease S-T depression was most often seen in the inferior leads and leads V4 to V6, and in the 18 patients with right coronary artery disease and in the 6 patients with left circumflex artery disease S-T depression was most often seen in leads V5 and V6. Although S-T segment elevation was uncommon in most leads, it occurred in lead V1 or a VL, or both, in 51 percent of the patients with left anterior descending coronary artery disease. A reversible anterior defect on exercise thallium scanning correlated with left anterior descending coronary artery disease (probability [p] less than 0.0001) and a reversible inferior thallium defect correlated with right coronary or left circumflex artery disease (p less than 0.0001). In patients with single vessel disease, the site of S-T segment depression does not identify the obstructed coronary artery; S-T segment elevation in lead V1 or aVL, or both, identifies left anterior descending coronary artery disease; and the site of reversible perfusion defect on thallium scanning identifies the site of myocardial ischemia and the obstructed coronary artery

  11. Man with a Swollen Eye: Nonspecific Orbital Inflammation in an Adult in the Emergency Department.

    Science.gov (United States)

    Zhang, Xiao Chi; Statler, Brittney; Suner, Selim; Lloyd, Maureen; Curley, David; Migliori, Michael E

    2018-07-01

    Nonspecific orbital inflammation (NSOI) is a rare idiopathic ocular pathology characterized by unilateral, painful orbital swelling without identifiable infectious or systemic disorders, which can be complicated by optic nerve compromise. A 50-year-old man presented to the Emergency Department with recurring, progressive painless left eye swelling, decreased visual acuity, and binocular diplopia in the absence of trauma, infection, or known malignancy. His physical examination was notable for left-sided decreased visual acuity, an afferent pupillary defect, severe left eye proptosis and chemosis, and restricted extraocular movements; his dilatated funduscopic examination was notable for ipsilateral retinal folds within the macula, concerning for a disruption between the sclera and the retina. Ocular examination of the right eye was unremarkable. Laboratory data were unrevealing. Gadolinium-enhanced magnetic resonance imaging showed marked thickening of the left extraocular muscles associated with proptosis, dense inflammatory infiltration of the orbital fat, and characteristics consistent with perineuritis. The patient was diagnosed with NSOI with optic neuritis and admitted for systemic steroid therapy; he was discharged on hospital day 2 after receiving high-dose intravenous (i.v.) methylprednisolone with significant improvement. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: NSOI is a rare and idiopathic ocular emergency, with clinical mimicry resembling a broad spectrum of systemic diseases such as malignancy, autoimmune diseases, endocrine disorders, and infection. Initial work-up for new-onset ocular proptosis should include comprehensive laboratory testing and gadolinium-enhanced magnetic resonance imaging. Timely evaluation by an ophthalmologist is crucial to assess for optic nerve involvement. Signs of optic nerve compromise include decreased visual acuity, afferent pupillary defect, or decreased color saturation. Patients with optic nerve compromise

  12. Radiation protection for the eyes of the children experiencing an operation of artificial cochlear implant against CT scan

    International Nuclear Information System (INIS)

    Liu Changsheng; Zheng Xiaohua; Li Maojing; Wei Wenzhou; Pan Ewu; Tang Guangqiao; Zhang Duanlian

    2006-01-01

    Objective: To optimize the CT scanning parameters in pediatric temporal bone examination with artificial cochlear implant and reduce its radiation hazards. Methods: The temporal bones of 87 patients with suspected inner ear disease which include 31 experienced artificial cochlear implant were scanned by HRCT. Regarding adult scan parameters as a criteria, properly adjusted the scanning dose and scanning angle until the quality of CT images was beyond the diagnosis demands. Finally the exposed doses, single scanning CT dose index weighted (CTDI w ) and dose length product (DLP) were analysed. Results: Compared with adult temporal bone scanning, the exposure value and CTDI w were reduced to 66.67%-83.33%, DLP of temporal bone scanning in pediatrics was reduced to 66.67%-83.33%, moreover, the imaging quality of tridimensional reconstruction for inner ear and implant electrode was improved. Conclusion: The proper reduction of CT scan exposure on preoperative and postoperative children with cochlear implants and the proper adjustment of scan angle can significantly reduce the exposure dose to local temporal bone and effectually avoid the damage to lens of children. (authors)

  13. A False Positive {sup 18}F-FDG PET/CT Scan Caused by Breast Silicone Injection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chao Jung; Lee, Bi Fang; Yao, Wei Jen; Wu, Pei Shan; Chen, Wen Chung; Peng, Shu Lin; Chiu, Nan Tsing [Cheng Kung University Medical College and Hospital, Tainan (Turkmenistan)

    2009-04-15

    We present here the case of a 40-year-old woman with a greater than 10 year prior history of bilateral breast silicone injection and saline bag implantation. Bilateral palpable breast nodules were observed, but the ultrasound scan was suboptimal and the magnetic resonance imaging showed no gadolinium enhanced tumor. The {sup 18}F-FDG PET/CT scan showed a hypermetabolic nodule in the left breast with a 30% increase of {sup 18}F-FDG uptake on the delayed imaging, and this mimicked breast cancer. She underwent a left partial mastectomy and the pathology demonstrated a siliconoma.

  14. Long-term efficacy of linear-scanning 808 nm diode laser for hair removal compared to a scanned alexandrite laser.

    Science.gov (United States)

    Grunewald, Sonja; Bodendorf, Marc Oliver; Zygouris, Alexander; Simon, Jan Christoph; Paasch, Uwe

    2014-01-01

    Alexandrite and diode lasers are commonly used for hair removal. To date, the available spot sizes and repetition rates are defining factors in terms of penetration depth, treatment speed, and efficacy. Still, larger treatment areas and faster systems are desirable. To compare the efficacy, tolerability, and subject satisfaction of a continuously linear-scanning 808 nm diode laser with an alexandrite 755 nm laser for axillary hair removal. A total of 31 adults with skin types I-IV received 6 treatments at 4-week intervals with a 755 nm alexandrite laser (right axilla) and a continuously linear-scanning 808 nm diode laser (left axilla). Axillary hair density was assessed using a computerized hair detection system. There was a significant reduction in axillary hair after the 6th treatment (P lasers was not significant, but both were persistant at 18 months follow-up (left: hair clearance of 73.71%; right: hair clearance of 71.90%). Erythema and perifollicular edema were more common after alexandrite laser treatment, but all side effects were transient. While 62.50% of patients reported more pain in response to treatment with the new diode laser, all patients rated treatment with either laser tolerable. Treatment with either the alexandrite or the linear-scanning diode laser results in significant, comparable, persistent (at least 18 months) axillary hair reduction among individuals with skin types I-IV. © 2013 Wiley Periodicals, Inc.

  15. Nonlinear Optical Characteristics of Crystal VioletDye Doped Polystyrene Films by Using Z-Scan Technique

    Directory of Open Access Journals (Sweden)

    Mahasin F. Hadi

    2017-07-01

    Full Text Available Z-scan technique was employed to study the nonlinear optical properties (nonlinear refractive index and nonlinear absorption coefficient for crystal violet doped polystyrene films as a function of doping ratio in chloroform solvent. Samples exhibits in closed aperture Z-scan positive nonlinear refraction (self-focusing. While in the open aperture Z-scan gives reverse saturation absorption (RSA (positive absorption for all film with different doping ratio making samples candidates for optical limiting devices for protection of sensors and eyes from energetic laser light pulses under the experimental conditions.

  16. DOME-SHAPED MACULA IN MYOPIC EYES: Twelve-Month Follow-up.

    Science.gov (United States)

    Lorenzo, Daniel; Arias, Luis; Choudhry, Netan; Millan, Eduard; Flores, Ignacio; Rubio, Marcos J; Cobos, Estefanía; García-Bru, Pere; Filloy, Alejandro; Caminal, Josep M

    2017-04-01

    To study the long-term clinical course of dome-shaped macula in myopic eyes and to evaluate treatment efficacy for subretinal fluid (SRF) as a related complication. A retrospective, single-center consecutive case series study was conducted. The authors analyzed myopic eyes with dome-shaped macula in patients who presented for evaluation of decreased vision. Dome-shaped macula was defined as a convexity of the retina-choroidal macular complex seen on spectral domain optical coherence tomography images. All patients were followed for at least 12 months (mean, 25 months). Fluorescein angiography and/or indocyanine green angiography were performed in cases with SRF to rule out choroidal neovascularization. A total of 56 dome-shaped macula eyes from 36 patients were included in the study (bilateral in 55% of patients). Mean patient age was 56.9 ± 13.1 years. The mean spherical equivalent was -9.1 ± 6.0 diopters; 53% of eyes were considered highly myopic (>-6 diopters) and 47% of eyes were mildly myopic. In most cases (37 eyes; 66.1%), the dome-shaped macula was detected on vertical spectral domain optical coherence tomography scan patterns. No significant changes (P ≥ 0.1) were observed in mean best-corrected visual acuity or mean central foveal thickness from baseline to final follow-up. Subretinal fluid was present in 29 eyes (51.8%) at baseline, with no differences in best-corrected visual acuity in eyes with and without SRF (P ≥ 0.05). Nineteen of the 29 SRF eyes were treated: 8 underwent low-fluence photodynamic therapy, whereas 7 received bevacizumab, and 4 ranibizumab. No significant differences were found between treated and untreated SRF eyes in best-corrected visual acuity improvement (P ≥ 0.1), or complete resolution of SRF (P ≥ 0.1). Likewise, photodynamic therapy did not yield any significant benefit versus untreated eyes in best-corrected visual acuity or improvement of SRF. Dome-shaped macula is a condition associated with myopic eyes that seems

  17. A 2D eye gaze estimation system with low-resolution webcam images

    Directory of Open Access Journals (Sweden)

    Kim Jin

    2011-01-01

    Full Text Available Abstract In this article, a low-cost system for 2D eye gaze estimation with low-resolution webcam images is presented. Two algorithms are proposed for this purpose, one for the eye-ball detection with stable approximate pupil-center and the other one for the eye movements' direction detection. Eyeball is detected using deformable angular integral search by minimum intensity (DAISMI algorithm. Deformable template-based 2D gaze estimation (DTBGE algorithm is employed as a noise filter for deciding the stable movement decisions. While DTBGE employs binary images, DAISMI employs gray-scale images. Right and left eye estimates are evaluated separately. DAISMI finds the stable approximate pupil-center location by calculating the mass-center of eyeball border vertices to be employed for initial deformable template alignment. DTBGE starts running with initial alignment and updates the template alignment with resulting eye movements and eyeball size frame by frame. The horizontal and vertical deviation of eye movements through eyeball size is considered as if it is directly proportional with the deviation of cursor movements in a certain screen size and resolution. The core advantage of the system is that it does not employ the real pupil-center as a reference point for gaze estimation which is more reliable against corneal reflection. Visual angle accuracy is used for the evaluation and benchmarking of the system. Effectiveness of the proposed system is presented and experimental results are shown.

  18. Accurate estimation of dose distributions inside an eye irradiated with 106Ru plaques

    International Nuclear Information System (INIS)

    Brualla, L.; Sauerwein, W.; Sempau, J.; Zaragoza, F.J.; Wittig, A.

    2013-01-01

    Background: Irradiation of intraocular tumors requires dedicated techniques, such as brachytherapy with 106 Ru plaques. The currently available treatment planning system relies on the assumption that the eye is a homogeneous water sphere and on simplified radiation transport physics. However, accurate dose distributions and their assessment demand better models for both the eye and the physics. Methods: The Monte Carlo code PENELOPE, conveniently adapted to simulate the beta decay of 106 Ru over 106 Rh into 106 Pd, was used to simulate radiation transport based on a computerized tomography scan of a patient's eye. A detailed geometrical description of two plaques (models CCA and CCB) from the manufacturer BEBIG was embedded in the computerized tomography scan. Results: The simulations were firstly validated by comparison with experimental results in a water phantom. Dose maps were computed for three plaque locations on the eyeball. From these maps, isodose curves and cumulative dose-volume histograms in the eye and for the structures at risk were assessed. For example, it was observed that a 4-mm anterior displacement with respect to a posterior placement of a CCA plaque for treating a posterior tumor would reduce from 40 to 0% the volume of the optic disc receiving more than 80 Gy. Such a small difference in anatomical position leads to a change in the dose that is crucial for side effects, especially with respect to visual acuity. The radiation oncologist has to bring these large changes in absorbed dose in the structures at risk to the attention of the surgeon, especially when the plaque has to be positioned close to relevant tissues. Conclusion: The detailed geometry of an eye plaque in computerized and segmented tomography of a realistic patient phantom was simulated accurately. Dose-volume histograms for relevant anatomical structures of the eye and the orbit were obtained with unprecedented accuracy. This represents an important step toward an optimized

  19. Eyes Wide Open

    Directory of Open Access Journals (Sweden)

    Zoi Manesi

    2016-04-01

    Full Text Available Research from evolutionary psychology suggests that the mere presence of eye images can promote prosocial behavior. However, the “eye images effect” is a source of considerable debate, and findings across studies have yielded somewhat inconsistent support. We suggest that one critical factor may be whether the eyes really need to be watching to effectively enhance prosocial behavior. In three experiments, we investigated the impact of eye images on prosocial behavior, assessed in a laboratory setting. Participants were randomly assigned to view an image of watching eyes (eyes with direct gaze, an image of nonwatching eyes (i.e., eyes closed for Study 1 and averted eyes for Studies 2 and 3, or an image of flowers (control condition. Upon exposure to the stimuli, participants decided whether or not to help another participant by completing a dull cognitive task. Three independent studies produced somewhat mixed results. However, combined analysis of all three studies, with a total of 612 participants, showed that the watching component of the eyes is important for decision-making in this context. Images of watching eyes led to significantly greater inclination to offer help as compared to images of nonwatching eyes (i.e., eyes closed and averted eyes or images of flowers. These findings suggest that eyes gazing at an individual, rather than any proxy to social presence (e.g., just the eyes, serve as a reminder of reputation. Taken together, we conclude that it is “eyes that pay attention” that can lift the veil of anonymity and potentially facilitate prosocial behavior.

  20. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. [Seoul National University Hospital (Korea, Republic of)

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  1. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    International Nuclear Information System (INIS)

    Park, J.

    2015-01-01

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  2. Pulmonary vein stenosis after RF ablation diagnosed on a V/Q lung scan - a case study

    International Nuclear Information System (INIS)

    Edwards, Russell G.

    2009-01-01

    Full text: A 26-year-old female presented to the emergency department with pleuritic chest pain, acute SOB and raised D-dimer. A PE was suspected and a V/Q lung scan was performed. The initial V/Q lung scan displayed normal ventilation images but reduced perfusion throughout the left lung. Further evaluation was required and a CTPA and repeat perfusion scan were performed. After review of these imaging procedures it was discovered the patient had poor opacification of her left upper pulmonary vein compared to the left lower and right pulmonary veins. Further investigation into the patient's medical history revealed she had undergone radiofrequency ablation for atrial fibrillation 12 months prior. This was significant as it is well documented that a delayed complication of radiofrequency ablation is pulmonary vein stenosis. Although it is rare for the stenosis to be severe enough to cause symptomatic complications from this treatment for atrial fibrillation, it is becoming more widely used and therefore cases are becoming more prevalent. The patient subsequently had a stent inserted into her stenosed pulmonary vein with symptomatic relief.

  3. Eye-hand laterality and right thoracic idiopathic scoliosis.

    Science.gov (United States)

    Catanzariti, Jean-François; Guyot, Marc-Alexandre; Agnani, Olivier; Demaille, Samantha; Kolanowski, Elisabeth; Donze, Cécile

    2014-06-01

    The adolescent idiopathic scoliosis (AIS) pathogenesis remains unknown. Certain studies have shown that there is a correlation between manual laterality and scoliotic deviation. A full study of manual laterality needs to be paired with one for visual dominance. With the aim of physiopathological research, we have evaluated the manual and visual laterality in AIS. A retrospective study from prospective data collection is used to evaluate the distribution of eye-hand laterality (homogeneous or crossed) of 65 right thoracic AIS (mean age 14.8 ± 1.8 years; mean Cobb angle: 32.8°) and a control group of 65 sex and age-matched (mean age 14.6 ± 1.8 years). The manual laterality was defined by the modified Edinburgh Handedness Inventory. The evaluation of the visual laterality is done using three tests (kaleidoscope test, hole-in-the-card test, distance-hole-in-the-card test). The group of right thoracic AIS presents a significantly higher frequency of crossed eye-hand laterality (63 %) than the control group (63 vs. 29.2 %; p laterality is "right hand dominant-left eye dominant" (82.9 %). There is no relationship with the Cobb angle. Those with right thoracic AIS show a higher occurrence of crossed eye-hand laterality. This could point physiopathological research of AIS towards functional abnormality of the optic chiasma through underuse of cross visual pathways, and in particular accessory optic pathways. It would be useful to explore this by carrying out research on AISs through neuroimaging and neurofunctional exploration.

  4. Prevalence of disc cupping in non-glaucomatous eyes

    Directory of Open Access Journals (Sweden)

    José Pablo Chiappe

    2015-02-01

    Full Text Available This study assessed optic disc size and cupping, using a commercially available ophthalmoscope, in order to show norms of these values for clinical practice. Subjects were office-workers referred from their respective workplaces for a routine medical examination, which included eye examination. The optic disc size was classified as small, medium or large, for having a diameter 1.5 times (respectively the diameter of the ophthalmoscope's selected light spot on the posterior pole. The cupping was classified as the ratio of the vertical cupping diameter and the vertical disc diameter on a relative decimal scale from 0.0 to 1.0.This study included 184 subjects with a mean age of 40.5 ± 9.5 years; 149 (81% were males. Their mean ocular pressure was 12.4 ± 1.5 mmHg (range 10-17 mmHg. There was a high correlation between optic disc sizes and cupping in the right and left eyes (Pearson Correlation r = 0.866, p < 0.001; therefore, for simplicity only the data for right eyes are presented. According to our definition, the optic discs in these eyes comprised 27 (14.7% small, 141 (76.6% medium and 16 (8.7% large. The small optic discs were rarely cupped, and the large optic discs were always cupped. Optic disc cupping greater than 0.7 was rarely found and should be suspect of glaucoma. Clinical doctors should be aware of this and refer those subjects with abnormal cupping to the specialist.

  5. Left, right, left, right, eyes to the front! Müller-Lyer bias in grasping is not a function of hand used, hand preferred or visual hemifield, but foveation does matter.

    OpenAIRE

    van der Kamp, J.; de Wit, M.M.; Masters, R.S.W.

    2012-01-01

    We investigated whether the control of movement of the left hand is more likely to involve the use of allocentric information than movements performed with the right hand. Previous studies (Gonzalez et al. in J Neurophys 95:3496-3501, 2006; De Grave et al. in Exp Br Res 193:421-427, 2009) have reported contradictory findings in this respect. In the present study, right-handed participants (N = 12) and left-handed participants (N = 12) made right- and left-handed grasps to foveated objects and...

  6. Renal mobility during uncoached quiet respiration: An analysis of 4DCT scans

    International Nuclear Information System (INIS)

    Soernsen de Koste, John R. van; Senan, Suresh; Kleynen, Catharina E.; Slotman, Ben J.; Lagerwaard, Frank J.

    2006-01-01

    Purpose: Data on organ mobility is required for optimizing radiotherapy. Renal mobility was studied in four-dimensional computed tomography (4DCT) scans acquired during uncoached respiration. Methods and Materials: The 4DCT scans of 54 patients, in whom at least the upper pole of both kidneys were visualized in all 10 respiratory phases, were analyzed. Scans were performed on a 16-slice CT scanner (slice index and reconstruction, 2.5 mm) during quiet, uncoached respiration. Mobility of the renal apex was evaluated in all patients by use of the z-position on CT slices. Reproducibility of mobility was studied in 8 patients who underwent 1 or 2 repeat 4DCT scans. Results: Mobility was predominantly craniocaudal, with a mean of 9.8 mm for the left kidney and 9.0 mm for the right kidney. Large interpatient variations were observed that ranged from 2.5 to 30 mm (left) and 2.5 to 20 mm (right), and mobility of 1 kidney did not predict for mobility of the contralateral organ. Reproducibility of renal mobility and position at end-expiration was poor, with positional variations in repeat scans appearing to correlate with changes in the amplitude of respiratory waveform and total lung volume. Conclusions: Large interpatient variations in renal movement occur during uncoached respiration, which indicates that respiratory coaching is useful for 4DCT imaging and treatment delivery

  7. Differential involvement of left prefrontal cortex in inductive and deductive reasoning.

    Science.gov (United States)

    Goel, Vinod; Dolan, Raymond J

    2004-10-01

    While inductive and deductive reasoning are considered distinct logical and psychological processes, little is known about their respective neural basis. To address this issue we scanned 16 subjects with fMRI, using an event-related design, while they engaged in inductive and deductive reasoning tasks. Both types of reasoning were characterized by activation of left lateral prefrontal and bilateral dorsal frontal, parietal, and occipital cortices. Neural responses unique to each type of reasoning determined from the Reasoning Type (deduction and induction) by Task (reasoning and baseline) interaction indicated greater involvement of left inferior frontal gyrus (BA 44) in deduction than induction, while left dorsolateral (BA 8/9) prefrontal gyrus showed greater activity during induction than deduction. This pattern suggests a dissociation within prefrontal cortex for deductive and inductive reasoning.

  8. Design of a Compact, Bimorph Deformable Mirror-Based Adaptive Optics Scanning Laser Ophthalmoscope.

    Science.gov (United States)

    He, Yi; Deng, Guohua; Wei, Ling; Li, Xiqi; Yang, Jinsheng; Shi, Guohua; Zhang, Yudong

    2016-01-01

    We have designed, constructed and tested an adaptive optics scanning laser ophthalmoscope (AOSLO) using a bimorph mirror. The simulated AOSLO system achieves diffraction-limited criterion through all the raster scanning fields (6.4 mm pupil, 3° × 3° on pupil). The bimorph mirror-based AOSLO corrected ocular aberrations in model eyes to less than 0.1 μm RMS wavefront error with a closed-loop bandwidth of a few Hz. Facilitated with a bimorph mirror at a stroke of ±15 μm with 35 elements and an aperture of 20 mm, the new AOSLO system has a size only half that of the first-generation AOSLO system. The significant increase in stroke allows for large ocular aberrations such as defocus in the range of ±600° and astigmatism in the range of ±200°, thereby fully exploiting the AO correcting capabilities for diseased human eyes in the future.

  9. Rhegmatogenous retinal detachment in an eye of retinoblastoma treated by radiation and cryocoagulation

    International Nuclear Information System (INIS)

    Inoue, Makoto; Tanaka, Yasuhiko; Kawai, Masataka; Nii, Seiji; Katsura, Hiroshi; Kaneko, Akihiro

    1999-01-01

    A 4-month-old female infant was diagnosed as bilateral retinoblastoma. The left eye was treated by enucleation and the right by radiation. The right eye received repeated thermochemotherapy, cryocoagulation and photocoagulation for recurrence. Total retinal detachment was detected after surgery for complicated cataract at the age of 2 years 9 months. Vitreous surgery led to the detection of posterior vitreous detachment and retinal breaks in the coagulated scar areas with vitreoretinal adhesion around the calcified tumor. During the following one year, the retina has been attached with no reoccurrence of the tumor. This case illustrates that rhegmatogenous retinal detachment is a possibility in retinoblastoma treated by radiation or retinal coagulations. (author)

  10. Radiation exposure of cardiologists eye lenses during interventional procedures

    International Nuclear Information System (INIS)

    Treckova, V.; Nikodemova, D.; Salat, D.

    2014-01-01

    Recently published studies have indicated a lower threshold of eye lens doses for developing cataracts than previously used. These studies have shown that the latency period responsible for cataract development depends on the absorbed eye lens dose. The recommendations of the ICRP, the new BSS of IAEA and the 2013/59/EURATOM Directive revise the old occupational limit of equivalent dose (150 mSv) to the new lower value of 20 mSv per year. Probably this value will be exceeded mainly during specific interventional procedures. The main aim of the present study was to investigate the received eye lens doses by monitoring and assessment of radiation load of cardiologists in the particular Cardiologic Healthcare Facility in Slovakia. The measurements were realized by using TLD located on the both sides of the protective lead glasses of five cardiologists during CA/PTCA procedures, performed in the period of 1 month. Evaluation of the dosimeters was performed by HARSHAW TLD 3500. Collected parameters of each individual examination were expressed in the quantity personal dose equivalent Hp(0,07). The whole body doses during the CA/PTCA procedures were controlled by RaySafe i2 dosimetry system, allowing the collection of real time radiation exposure of medical staff. Values of personal dose equivalent Hp(0,07) on the left eye lens (where we observed higher dose values), were extrapolated to annual doses and compared with the new eye lens limit. The comparison of the results (calculating the average annual dose from the gathered annual workload of each cardiologist) indicates that the new proposed limit for eye lens doses (20 mSv/year) should be exceeded. Important information comes from the results of RaySafe measurements, which refer to the fact, that although the whole-body annual doses obtained by the followed cardiologists doses not exceed the annual limit of effective dose, the equivalent doses to the lens of the eye obtained from TLD, reached the overflow value

  11. Radiation exposure of cardiologists eye lenses during interventional procedures

    International Nuclear Information System (INIS)

    Treckova, V.; Nikodemova, D.; Salat, D.

    2014-01-01

    Recently published studies have indicated a lower threshold of eye lens doses for developing cataracts than previously used. These studies have shown that the latency period responsible for cataract development depends on the absorbed eye lens dose. The recommendations of the ICRP, the new BSS of IAEA and the 2013/59/EURATOM Directive revise the old occupational limit of equivalent dose (150 mSv) to the new lower value of 20 mSv per year. Probably this value will be exceeded mainly during specific interventional procedures. The main aim of the present study was to investigate the received eye lens doses by monitoring and assessment of radiation load of cardiologists in the particular Cardio logic Healthcare Facility in Slovakia. The measurements were realized by using TLD located on the both sides of the protective lead glasses of five cardiologists during CA/PTCA procedures, performed in the period of 1 month. Evaluation of the dosimeters was performed by HARSHAW TLD 3500. Collected parameters of each individual examination were expressed in the quantity personal dose equivalent Hp(0,07). The whole body doses during the CA/PTCA procedures were controlled by RaySafe i2 dosimetry system, allowing the collection of real time radiation exposure of medical staff. Values of personal dose equivalent Hp(0,07) on the left eye lens (where we observed higher dose values), were extrapolated to annual doses and compared with the new eye lens limit. The comparison of the results (calculating the average annual dose from the gathered annual workload of each cardiologist) indicates that the new proposed limit for eye lens doses (20 mSv/year) should be exceeded. Important information comes from the results of RaySafe measurements, which refer to the fact, that although the whole-body annual doses obtained by the followed cardiologists doses not exceed the annual limit of effective dose, the equivalent doses to the lens of the eye obtained from TLD, reached the overflow value

  12. Performance of confocal scanning laser tomograph Topographic Change Analysis (TCA) for assessing glaucomatous progression.

    Science.gov (United States)

    Bowd, Christopher; Balasubramanian, Madhusudhanan; Weinreb, Robert N; Vizzeri, Gianmarco; Alencar, Luciana M; O'Leary, Neil; Sample, Pamela A; Zangwill, Linda M

    2009-02-01

    To determine the sensitivity and specificity of confocal scanning laser ophthalmoscope's Topographic Change Analysis (TCA; Heidelberg Retina Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany) parameters for discriminating between progressing glaucomatous and stable healthy eyes. The 0.90, 0.95, and 0.99 specificity cutoffs for various (n=70) TCA parameters were developed by using 1000 permuted topographic series derived from HRT images of 18 healthy eyes from Moorfields Eye Hospital, imaged at least four times. The cutoffs were then applied to topographic series from 36 eyes with known glaucomatous progression (by optic disc stereophotograph assessment and/or standard automated perimetry guided progression analysis, [GPA]) and 21 healthy eyes from the University of California, San Diego (UCSD) Diagnostic Innovations in Glaucoma Study (DIGS), all imaged at least four times, to determine TCA sensitivity and specificity. Cutoffs also were applied to 210 DIGS patients' eyes imaged at least four times with no evidence of progression (nonprogressed) by stereophotography or GPA. The TCA parameter providing the best sensitivity/specificity tradeoff using the 0.90, 0.95, and 0.99 cutoffs was the largest clustered superpixel area within the optic disc margin (CAREA(disc) mm(2)). Sensitivities/specificities for classifying progressing (by stereophotography and/or GPA) and healthy eyes were 0.778/0.809, 0.639/0.857, and 0.611/1.00, respectively. In nonprogressing eyes, specificities were 0.464, 0.570, and 0.647 (i.e., lower than in the healthy eyes). In addition, TCA parameter measurements of nonprogressing eyes were similar to those of progressing eyes. TCA parameters can discriminate between progressing and longitudinally observed healthy eyes. Low specificity in apparently nonprogressing patients' eyes suggests early progression detection using TCA.

  13. Optical coherence tomographic view of persistent primary fetal vasculature

    International Nuclear Information System (INIS)

    Shenoy, R.; Al-Kharousi, Nadia S.; Bialasiewicz, Alexander A.

    2006-01-01

    Purpose was to report on the posterior segment changes in a patient with bilateral persistent primary fetal vasculature as detected by optical coherence tomography. An 18-year-old lady with poor vision, left esotropia and bilateral posterior polar cataract was found to have dysplasia of the macula in the both eyes. Fundus fluorescein angiography, optical coherence tomography, ''A'' scan biometry and genetic work up was performed as a part of investigation. There was increase in thickness of the macular area in both the eyes (450-500mm). The left eye showed a ''sail like'' fold extending over macula, from nasal to temporal side. The tissue had the same sensitivity and thickness as inner the retinal layers (180-200). There was no detectable nerve fibre layer in the macula of either eye. Fundus fluorescein angiography was normal in the right eye, and showed hyperfluorescence at the inferior pole of the disk in the left eye corresponding to the Bergmeister papilla. There was no staining of the membrane with the dye. Evaluation of the posterior segment is important in predicting the visual outcome in patients with any from of PFV. Optical coherence tomography is an adjuvant to direct visualization and aids in further delineating posterior segment changes seen in this condition. (author)

  14. Sturge Weber Syndrome: review of literature with case illustration

    Directory of Open Access Journals (Sweden)

    Satyarthee Guru Dutta

    2017-03-01

    Full Text Available Sturge-Weber syndrome (SWS also called as encephalotrigeminal angiomatosis, is a sporadically occurring rare neuro-cutaneous syndrome, characterized by vascular malformation with capillary venous angiomas involving face, choroidal layer of eye globe and leptomeninges responsible for ophthamological as well as neurological signs and symptoms. Authors report an interesting case, a six year old girl, who presented with seizures, facial port wine stain and normal psychomotor development. CT scan showed left cerebral hemiatrophy, left frontal and parieto occipital calcification with cortical calcification in left high frontal convexity. Cranial MRI scan also confirmed finding of left cerebral hemiatrophy and also revealed presence of gyriform cortical calcification, prominent flow voids seen in left basal ganglia. Her seizure is well controlled with antiepileptic medication. The pertinent literature is reviewed and management of such cases is discussed briefly.

  15. Vision in semi-aquatic snakes: Intraocular morphology, accommodation, and eye: Body allometry

    Science.gov (United States)

    Plylar, Helen Bond

    Vision in vertebrates generally relies on the refractive power of the cornea and crystalline lens to facilitate vision. Light from the environment enters the eye and is refracted by the cornea and lens onto the retina for production of an image. When an animal with a system designed for air submerges underwater, the refractive power of the cornea is lost. Semi-aquatic animals (e.g., water snakes, turtles, aquatic mammals) must overcome this loss of corneal refractive power through visual accommodation. Accommodation relies on change of the position or shape of the lens to change the focal length of the optical system. Intraocular muscles and fibers facilitate lenticular displacement and deformation. Snakes, in general, are largely unstudied in terms of visual acuity and intraocular morphology. I used light microscopy and scanning electron microscopy to examine differences in eye anatomy between five sympatric colubrid snake species (Nerodia cyclopion, N. fasciata, N. rhombifer, Pantherophis obsoletus, and Thamnophis proximus) from Southeast Louisiana. I discovered previously undescribed structures associated with the lens in semi-aquatic species. Photorefractive methods were used to assess refractive error. While all species overcame the expected hyperopia imposed by submergence, there was interspecific variation in refractive error. To assess scaling of eye size with body size, I measure of eye size, head size, and body size in Nerodia cyclopion and N. fasciata from the SLU Vertebrate Museum. In both species, body size increases at a significantly faster rate than head size and eye size (negative allometry). Small snakes have large eyes relative to body size, and large snakes have relatively small eyes. There were interspecific differences in scaling of eye size with body size, where N. fasciata had larger eye diameter, but N. cyclopion had longer eyes (axial length).

  16. SU-C-BRB-06: Utilizing 3D Scanner and Printer for Dummy Eye-Shield: Artifact-Free CT Images of Tungsten Eye-Shield for Accurate Dose Calculation

    International Nuclear Information System (INIS)

    Park, J; Lee, J; Kim, H; Kim, I; Ye, S

    2015-01-01

    Purpose: To evaluate the effect of a tungsten eye-shield on the dose distribution of a patient. Methods: A 3D scanner was used to extract the dimension and shape of a tungsten eye-shield in the STL format. Scanned data was transferred into a 3D printer. A dummy eye shield was then produced using bio-resin (3D systems, VisiJet M3 Proplast). For a patient with mucinous carcinoma, the planning CT was obtained with the dummy eye-shield placed on the patient’s right eye. Field shaping of 6 MeV was performed using a patient-specific cerrobend block on the 15 x 15 cm 2 applicator. The gantry angle was 330° to cover the planning target volume near by the lens. EGS4/BEAMnrc was commissioned from our measurement data from a Varian 21EX. For the CT-based dose calculation using EGS4/DOSXYZnrc, the CT images were converted to a phantom file through the ctcreate program. The phantom file had the same resolution as the planning CT images. By assigning the CT numbers of the dummy eye-shield region to 17000, the real dose distributions below the tungsten eye-shield were calculated in EGS4/DOSXYZnrc. In the TPS, the CT number of the dummy eye-shield region was assigned to the maximum allowable CT number (3000). Results: As compared to the maximum dose, the MC dose on the right lens or below the eye shield area was less than 2%, while the corresponding RTP calculated dose was an unrealistic value of approximately 50%. Conclusion: Utilizing a 3D scanner and a 3D printer, a dummy eye-shield for electron treatment can be easily produced. The artifact-free CT images were successfully incorporated into the CT-based Monte Carlo simulations. The developed method was useful in predicting the realistic dose distributions around the lens blocked with the tungsten shield

  17. SU-C-BRB-06: Utilizing 3D Scanner and Printer for Dummy Eye-Shield: Artifact-Free CT Images of Tungsten Eye-Shield for Accurate Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Park, J; Lee, J [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of); Kim, H [Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, I [Department of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Ye, S [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of); Department of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Advanced Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2015-06-15

    Purpose: To evaluate the effect of a tungsten eye-shield on the dose distribution of a patient. Methods: A 3D scanner was used to extract the dimension and shape of a tungsten eye-shield in the STL format. Scanned data was transferred into a 3D printer. A dummy eye shield was then produced using bio-resin (3D systems, VisiJet M3 Proplast). For a patient with mucinous carcinoma, the planning CT was obtained with the dummy eye-shield placed on the patient’s right eye. Field shaping of 6 MeV was performed using a patient-specific cerrobend block on the 15 x 15 cm{sup 2} applicator. The gantry angle was 330° to cover the planning target volume near by the lens. EGS4/BEAMnrc was commissioned from our measurement data from a Varian 21EX. For the CT-based dose calculation using EGS4/DOSXYZnrc, the CT images were converted to a phantom file through the ctcreate program. The phantom file had the same resolution as the planning CT images. By assigning the CT numbers of the dummy eye-shield region to 17000, the real dose distributions below the tungsten eye-shield were calculated in EGS4/DOSXYZnrc. In the TPS, the CT number of the dummy eye-shield region was assigned to the maximum allowable CT number (3000). Results: As compared to the maximum dose, the MC dose on the right lens or below the eye shield area was less than 2%, while the corresponding RTP calculated dose was an unrealistic value of approximately 50%. Conclusion: Utilizing a 3D scanner and a 3D printer, a dummy eye-shield for electron treatment can be easily produced. The artifact-free CT images were successfully incorporated into the CT-based Monte Carlo simulations. The developed method was useful in predicting the realistic dose distributions around the lens blocked with the tungsten shield.

  18. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients.

    Science.gov (United States)

    Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A

    2013-01-01

    Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40-69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008-2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months' supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies.

  19. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  20. A case of Neuro-Behcet's disease with an interesting CT scan picture

    International Nuclear Information System (INIS)

    Sato, Jinichi; Kamitani, Hiroshi; Masuzawa, Hideaki; Matsui, Takayoshi; Mizobe, Masafumi.

    1981-01-01

    A Case of Neuro-Behcet's disease with an interesting CT scan picture was reported. A 31-year-old man with a known history of Behcet's disease was transferred to the Kantoh-Teishin Hospital upon suspicion of a brain tumor in the basal ganglia. Right hemiparesis and mild dysarthria of three weeks' duration and long-standing bilateral blindness were noted. Computerized tomography (CT) demonstrated an enhanced mass in the basal ganglia and surrounding irregular, low-density area in the white matter of the left frotoparietal lobe. The ventricles were shifted to the right. Left carotid angiography revealed a shift of the anterior cerebral artery to the right and a mild deformity of the Sylvian triangle. No tumor stain or abnormal vessels were seen. After high doses of prednisolone, his condition gradually improved. A CT scan two weeks later revealed a decrease in the low-density area and the mass effect, but an unchanged pathological contrast enhancement in the basal ganglia. The contrast enhancement lasted for two months. The CT scan of Neuro-Behcet's disease was discussed. (author)

  1. Bags Under Eyes

    Science.gov (United States)

    Bags under eyes Overview Bags under eyes — mild swelling or puffiness under the eyes — are common as you age. With aging, the tissues around your ... space below your eyes, adding to the swelling. Bags under eyes are usually a cosmetic concern and ...

  2. Subretinal drusenoid deposits with increased autofluorescence in eyes with reticular pseudodrusen.

    Science.gov (United States)

    Lee, Mee Yon; Ham, Don-Il

    2014-01-01

    To characterize a variant type of drusenoid deposit with different imaging features in comparison to reticular pseudodrusen. Retrospective observational consecutive case series. Eyes showing atypical drusenoid lesions were sorted out from 257 eyes of 133 patients previously diagnosed as reticular pseudodrusen. Eyes were evaluated using color fundus photography, confocal scanning laser ophthalmoscopy, and spectral domain optical coherence tomography. A variant type of drusenoid deposits showing different imaging features from reticular pseudodrusen was found in 17 eyes of 12 patients (6.6%). The mean age of patients was 62.7 ± 11.6 years, and all patients were women. These deposits were observed as yellowish white, round to oval lesions on color photographs, located under the sensory retina and above the retinal pigment epithelium on spectral domain optical coherence tomography similar to reticular pseudodrusen. However, they were present in a smaller number as discrete lesions and showed increased autofluorescence. None of them were accompanied by late age-related macular degeneration. Subretinal drusenoid deposits are not homogeneous and can be classified into two types according to the fundus autofluorescence. Multimodal imaging tests are needed for the differential diagnosis of subretinal drusenoid deposits.

  3. Staff exposure in pediatric interventional neuroradiology: focus on the operator's eye lens

    International Nuclear Information System (INIS)

    Bolomey, C.; Fasel, G.; Le Coultre, R.; Ryckx, N.

    2016-01-01

    Previously at 150 mSv year -1 , the ICRP now recommends limiting the equivalent dose to the eye lens to 20 mSv year -1 . For pediatric interventional neuroradiology, the exposure of the operator's eye lens may be increased by the use of a biplane fluoroscopy system and by the proximity of the physician to the patient. In practice, the efficiency of leaded glasses depends on many factors. This study addresses both aspects. First, the eye lens dose of a neuro-radiologist was measured during 12 procedures using 36 TLDs placed on his surgical cap. Secondly, in order to determine the efficiency of leaded glasses, measurements were carried out by reproducing the clinical conditions. A detector was placed on the left eye of a phantom representing the operator. Four pairs of leaded glasses were selected to test various parameters. During the 12 procedures, an individual dose equivalent Hp(0.07) of 45μSv was obtained for the eye lens closest to the tube. This study shows an eye lens dose to DAP ratio 5 times higher than for procedures performed on adult patients. The eye lens dose might be reduced by a factor of approximately 3 with the use of appropriate leaded glasses. The eye wear model with the most coverage reduces the dose by up to 50% more than the model with the least coverage. The addition of lateral protection increases the attenuation by up to 13% compared with the same model without side protection. (authors)

  4. Evaluation of intracameral injection of ranibizumab and bevacizumab on the corneal endothelium by scanning electron microscopy.

    Science.gov (United States)

    Ari, Seyhmus; Nergiz, Yusuf; Aksit, Ihsan; Sahin, Alparslan; Cingu, Kursat; Caca, Ihsan

    2015-03-01

    To evaluate the effects of intracameral injection of ranibizumab and bevacizumab on the corneal endothelium by scanning electron microscopy (SEM). Twenty-eight female rabbits were randomly divided into four equal groups. Rabbits in groups 1 and 2 underwent intracameral injection of 1 mg/0.1 mL and 0.5 mg/0.05 mL ranibizumab, respectively; group 3 was injected with 1.25 mg/0.05 mL bevacizumab. All three groups were injected with a balanced salt solution (BSS) into the anterior chamber of the left (fellow) eye. None of the rabbits in group 4 underwent an injection. Corneal thickness and intraocular pressure were measured before the injections, on the first day, and in the first month after injection. The rabbits were sacrificed and corneal tissues were excised in the first month after injection. Specular microscopy was used for the corneal endothelial cell count. Endothelial cell density was assessed and comparisons drawn between the groups and the control. Micrographs were recorded for SEM examination. The structure of the corneal endothelial cells, the junctional area of the cell membrane, the distribution of microvillus, and the cell morphology of the eyes that underwent intracameral injection of vascular endothelial growth factor (VEGF), BSS, and the control group were compared. Corneal thickness and intraocular pressure were not significantly different between the groups that underwent anti-VEGF or BSS injection and the control group on the first day and in the first month of injection. The corneal endothelial cell count was significantly diminished in all three groups; predominantly in group 1 and 2 (P<0.05). The SEM examination revealed normal corneal endothelial histology in group 3 and the control group. Eyes in group 1 exhibited indistinctness of corneal endothelial cell borders, microvillus loss in the luminal surface, excessive blebbing, and disintegration of intercellular junctions. In group 2, the cell structure of the corneal endothelium

  5. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  6. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Stories Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  7. Automated diagnosis of dry eye using infrared thermography images

    Science.gov (United States)

    Acharya, U. Rajendra; Tan, Jen Hong; Koh, Joel E. W.; Sudarshan, Vidya K.; Yeo, Sharon; Too, Cheah Loon; Chua, Chua Kuang; Ng, E. Y. K.; Tong, Louis

    2015-07-01

    Dry Eye (DE) is a condition of either decreased tear production or increased tear film evaporation. Prolonged DE damages the cornea causing the corneal scarring, thinning and perforation. There is no single uniform diagnosis test available to date; combinations of diagnostic tests are to be performed to diagnose DE. The current diagnostic methods available are subjective, uncomfortable and invasive. Hence in this paper, we have developed an efficient, fast and non-invasive technique for the automated identification of normal and DE classes using infrared thermography images. The features are extracted from nonlinear method called Higher Order Spectra (HOS). Features are ranked using t-test ranking strategy. These ranked features are fed to various classifiers namely, K-Nearest Neighbor (KNN), Nave Bayesian Classifier (NBC), Decision Tree (DT), Probabilistic Neural Network (PNN), and Support Vector Machine (SVM) to select the best classifier using minimum number of features. Our proposed system is able to identify the DE and normal classes automatically with classification accuracy of 99.8%, sensitivity of 99.8%, and specificity if 99.8% for left eye using PNN and KNN classifiers. And we have reported classification accuracy of 99.8%, sensitivity of 99.9%, and specificity if 99.4% for right eye using SVM classifier with polynomial order 2 kernel.

  8. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  9. Eye Care Professionals' Perspectives on Eye Donation and an Eye Donation Registry for Research: A Single-Institution, Cross-Sectional Study.

    Science.gov (United States)

    Williams, Andrew M; Allingham, R Rand; Stamer, W Daniel; Muir, Kelly W

    2016-06-01

    A centralized eye donation registry for research could help to bridge the gap between patients interested in donating their eyes to science and scientists who conduct research on human eye tissue. Previous research has demonstrated patient and family support for such a registry. In this study, we assessed the views that eye care professionals have toward an eye donation registry for research. Surveys were distributed to all 46 clinical faculty members of the Duke University Eye Center. In addition to collecting demographic information, the surveys assessed clinicians' experience with discussing eye donation with patients, described the proposed eye donation registry for research and asked how the registry would affect the clinicians' practice. A total of 21 eye care professionals returned the survey. Thirty-three percent reported discussing eye donation with patients, and 43% reported that a patient has asked about donating their eyes for research on their disease. Eighty-six percent of eye care professionals reported that a centralized registry would improve the way they work with patients who express a desire to donate their eyes for research. The majority of eye care professionals at our academic institution indicated that an eye donation registry for research would improve how they work with patients who are interested in donating their eyes for research on their disease. Future research should examine how best to communicate this registry to ophthalmic patients.

  10. Repair of pectus excavatum in a toddler with Prune Belly syndrome and left bronchus compression

    Directory of Open Access Journals (Sweden)

    Shawn T. Liechty

    2017-01-01

    Full Text Available A 2-year-old boy with prune-belly syndrome and severe pectus excavatum experienced recurrent pulmonary infections. A CT scan of the chest demonstrated compression of the left mainstem bronchus and leftward shift of the heart. The bronchial compression resulted in left upper lobe collapse and left lower lobe air-trapping requiring two hospitalizations for respiratory distress and pneumonia. The child underwent minimally invasive repair of his pectus excavatum and has not experienced any further pulmonary events. The pectus bar was removed 3 years post-operatively and at seven years following surgery he has a sustained repair.

  11. Threat perception in the chameleon (Chamaeleo chameleon): evidence for lateralized eye use.

    Science.gov (United States)

    Lustig, Avichai; Keter-Katz, Hadas; Katzir, Gadi

    2012-07-01

    Chameleons are arboreal lizards with highly independent, large amplitude eye movements. In response to an approaching threat, a chameleon on a vertical pole moves so as to keep itself away from the threat. In so doing, it shifts between monocular and binocular scanning of the threat and of the environment. We analyzed eye movements in the Common chameleon, Chamaeleo chameleon, during avoidance response for lateralization, that is, asymmetry at the functional/behavioral levels. The chameleons were exposed to a threat, approaching horizontally from clockwise or anti-clockwise directions, and that could be viewed monocularly or binocularly. Our results show three broad patterns of eye use, as determined by durations spent viewing the threat and by frequency of eye shifts. Under binocular viewing, two of the patterns were found to be both side dependent, that is, lateralized and role dependent ("leading" or "following"). However, under monocular viewing, no such lateralization was detected. We discuss these findings in light of the situation not uncommon in vertebrates, of independent eye movements and a high degree of optic nerve decussation and that lateralization may well occur in organisms that are regularly exposed to critical stimuli from all spatial directions. We point to the need of further investigating lateralization at fine behavioral levels.

  12. The importance of the eyes: communication skills in infants of blind parents.

    Science.gov (United States)

    Senju, Atsushi; Tucker, Leslie; Pasco, Greg; Hudry, Kristelle; Elsabbagh, Mayada; Charman, Tony; Johnson, Mark H

    2013-06-07

    The effects of selectively different experience of eye contact and gaze behaviour on the early development of five sighted infants of blind parents were investigated. Infants were assessed longitudinally at 6-10, 12-15 and 24-47 months. Face scanning and gaze following were assessed using eye tracking. In addition, established measures of autistic-like behaviours and standardized tests of cognitive, motor and linguistic development, as well as observations of naturalistic parent-child interaction were collected. These data were compared with those obtained from a larger group of sighted infants of sighted parents. Infants with blind parents did not show an overall decrease in eye contact or gaze following when they observed sighted adults on video or in live interactions, nor did they show any autistic-like behaviours. However, they directed their own eye gaze somewhat less frequently towards their blind mothers and also showed improved performance in visual memory and attention at younger ages. Being reared with significantly reduced experience of eye contact and gaze behaviour does not preclude sighted infants from developing typical gaze processing and other social-communication skills. Indeed, the need to switch between different types of communication strategy may actually enhance other skills during development.

  13. Accurate estimation of dose distributions inside an eye irradiated with {sup 106}Ru plaques

    Energy Technology Data Exchange (ETDEWEB)

    Brualla, L.; Sauerwein, W. [Universitaetsklinikum Essen (Germany). NCTeam, Strahlenklinik; Sempau, J.; Zaragoza, F.J. [Universitat Politecnica de Catalunya, Barcelona (Spain). Inst. de Tecniques Energetiques; Wittig, A. [Marburg Univ. (Germany). Klinik fuer Strahlentherapie und Radioonkologie

    2013-01-15

    Background: Irradiation of intraocular tumors requires dedicated techniques, such as brachytherapy with {sup 106}Ru plaques. The currently available treatment planning system relies on the assumption that the eye is a homogeneous water sphere and on simplified radiation transport physics. However, accurate dose distributions and their assessment demand better models for both the eye and the physics. Methods: The Monte Carlo code PENELOPE, conveniently adapted to simulate the beta decay of {sup 106}Ru over {sup 106}Rh into {sup 106}Pd, was used to simulate radiation transport based on a computerized tomography scan of a patient's eye. A detailed geometrical description of two plaques (models CCA and CCB) from the manufacturer BEBIG was embedded in the computerized tomography scan. Results: The simulations were firstly validated by comparison with experimental results in a water phantom. Dose maps were computed for three plaque locations on the eyeball. From these maps, isodose curves and cumulative dose-volume histograms in the eye and for the structures at risk were assessed. For example, it was observed that a 4-mm anterior displacement with respect to a posterior placement of a CCA plaque for treating a posterior tumor would reduce from 40 to 0% the volume of the optic disc receiving more than 80 Gy. Such a small difference in anatomical position leads to a change in the dose that is crucial for side effects, especially with respect to visual acuity. The radiation oncologist has to bring these large changes in absorbed dose in the structures at risk to the attention of the surgeon, especially when the plaque has to be positioned close to relevant tissues. Conclusion: The detailed geometry of an eye plaque in computerized and segmented tomography of a realistic patient phantom was simulated accurately. Dose-volume histograms for relevant anatomical structures of the eye and the orbit were obtained with unprecedented accuracy. This represents an important step

  14. Biometric measurements in highly myopic eyes.

    Science.gov (United States)

    Shen, Peiyang; Zheng, Yingfeng; Ding, Xiaohu; Liu, Bin; Congdon, Nathan; Morgan, Ian; He, Mingguang

    2013-02-01

    To assess the repeatability and accuracy of optical biometry (Lenstar LS900 optical low-coherence reflectometry [OLCR] and IOLMaster partial coherence interferometry [PCI]) and applanation ultrasound biometry in highly myopic eyes. Division of Preventive Ophthalmology, Zhongshan Ophthalmic Center, Guangzhou, China. Comparative evaluation of diagnostic technology. Biometric measurements were taken in highly myopic subjects with a spherical equivalent (SE) of -6.00 diopters (D) or higher and an axial length (AL) longer than 25.0 mm. Measurements of AL and anterior chamber depth (ACD) obtained by OLCR were compared with those obtained by PCI and applanation A-scan ultrasound. Right eyes were analyzed. Repeatability was evaluated using the coefficient of variation (CoV) and agreement, using Bland-Altman analyses. The mean SE was -11.20 D ± 4.65 (SD). The CoVs for repeated AL measurements using OLCR, PCI, and applanation ultrasound were 0.06%, 0.07%, and 0.20%, respectively. The limits of agreement (LoA) for AL were 0.11 mm between OLCR and PCI, 1.01 mm between OLCR and applanation ultrasound, and 1.03 mm between PCI and ultrasound. The ACD values were 0.29 mm, 0.53 mm, and 0.51 mm, respectively. These repeatability and agreement results were comparable in eyes with extreme myopia (AL ≥ 27.0 mm) or posterior staphyloma. The mean radius of corneal curvature was similar between OLCR and PCI (7.66 ± 0.24 mm versus 7.64 ± 0.25 mm), with an LoA of 0.12 mm. Optical biometry provided more repeatable and precise measurements of biometric parameters, including AL and ACD, than applanation ultrasound biometry in highly myopic eyes. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Effect of tonicity on 22NaCl solution uptake by rabbit eye in vivo and in vitro

    International Nuclear Information System (INIS)

    Obenberger, J.; Bartosova, D.; Babicky, A.

    1979-01-01

    Solutions of 22 NaCl in saline or distilled water differ with respect to their ocular uptake. Studies were performed on eyes of living rabbits as well on the enucleated rabbit eyes. Chromatographic paper strips (15x2 mm) were soaked in both solutions, stretched over the cornea and left in contact for 1 min. Radioactivities of paper strips and rabbit eyes were measured and the ocular uptake of 22 Na was expressed as percentual values of the total radioactivities contained in the paper strips before their application to the corneal surface. Values of the ocular uptake of 22 NaCl solved in distilled water exceeded more than twice the values found in experiments where 22 Na solution in saline was used. The use of carrier-free 22 NaCl solutions in distilled water is recommended for the method measuring the ocular uptake hydrodynamics on basis of ocular 22 Na clearance. Uptake of 22 Na in enucleated eyes was twenty-five per cent higher in comparison with the eyes of living rabitts. (author)

  16. With computed tomography confirmed anterolateral left ventricular pseudoaneurysm in patient with dilatative alcoholic cardiomyopathy

    International Nuclear Information System (INIS)

    Letonja, Mitja; Letonja, Marija Santl

    2011-01-01

    Pseudoaneurysms are rare complications of myocardial infarction with propensity for rupture. There is still a challenge with which diagnostic imaging we performed a final diagnosis of pseudoaneurysm and differentiate it from true aneurysm what is clinically important due to the different treatment. We presented the unusual case of a 56-year-old man with signs of decompensated heart failure which had worsened a few months before hospitalization. We believed that during worsening of symptoms the patient suffered a silent myocardial infarction complicated by subacute free wall rupture which resulted into left ventricular pseudoaneurysm formation without tamponade. Echocardiography showed dilatative cardiomyopathy which was already present years before and a very rare location of the left ventricular pseudoaneurysm on the anterolateral part of the left ventricle. Pseudoaneurysm was confirmed with CT scan. Due to the severity of contractile dysfunction and no response in treatment for congestive heart failure the directive for the resection was tempered and the patient died due to the progressive heart failure and embolic phenomena. This report shows the importance of non-invasive imaging diagnostic evaluation of acute decompensated heart failure where echocardiography and chest X-ray are the first diagnostic steps. Based on those findings further imaging diagnostic steps must be performed such as CT scan in our case which finally confirms left ventricular pseudoaneurysm with dilatative cardiomyopathy

  17. Spleen injury following left extracorporeal shockwave lithotripsy (ESWL).

    Science.gov (United States)

    Marinkovic, Serge P; Marinkovic, Christina M; Xie, Donghua

    2015-02-18

    A splenic rupture associated with extracorporeal shockwave lithotripsy (ESWL) is exceedingly rare. We report a case of stage 3 splenic laceration, hemoperitoneum and subsequent splenic rupture following an ESWL for a left mid polar renal calculus. During the ESWL, although the patient's pain was controlled the gentleman was very nervous and had to be repositioned eight individual times. Approximately 6 hours after the ESWL, the patient phoned the urologist complaining of severe left flank pain unlike any previous episode of renal colic. A computerized tomography (CT) scan demonstrated a stage 3 splenic injury with hemoperitoneum. The patient decompensated and an emergent splenectomy was then performed and the patient experienced an uneventful recovery. Splenic injury likely results from unintentional movement during the sound wave administration for the stone fragmentation procedure. Utilizing noise cancelling headphones during ESWL may preclude the potential pitfalls of patient nervousness.

  18. The effect of vitamin A palmitate eye gel on ocular surface recovery after LASIK

    Directory of Open Access Journals (Sweden)

    Yan Lu

    2013-04-01

    Full Text Available AIM: To study the effect of vitamin A palmitate eye gel on ocular surface reconstruction after laser in situ keratomileusis(LASIK, and to evaluate the efficacy and safety. METHODS: One hundred and twenty patients(240 eyesperforming LASIK were enrolled in this study. The right and left eyes were randomly divided into experimental group and control group. The experimental group were treated with vitamin A palmitate eye gel for 1 month, four times a day after LASIK, and the same as control group in other treatments. The SchirmerⅠ test, break-up time(BUTand corneal sensation were detect at preoperation and the postoperative 1st day, 1st month, 3rd month in two groups. RESULTS: There were significant difference in BUT and tear secretion quantity between the experimental group and the control group at the postoperative 1st month and 3rd month(P0.05, which revealed that vitamin A palmitate eye gel had no obvious effect on recovery of corneal sensation after LASIK. During the treatment, there was no adverse drug event occurred. CONCLUSION: Early use of vitamin A palmitate eye gel postoperatively is applicable for ocular surface reconstruction, but has no obvious effect on the regeneration of corneal sensation.

  19. Assessment of diabetic retinopathy using nonmydriatic ultra-widefield scanning laser ophthalmoscopy (Optomap) compared with ETDRS 7-field stereo photography.

    Science.gov (United States)

    Kernt, Marcus; Hadi, Indrawati; Pinter, Florian; Seidensticker, Florian; Hirneiss, Christoph; Haritoglou, Christos; Kampik, Anselm; Ulbig, Michael W; Neubauer, Aljoscha S

    2012-12-01

    To compare the diagnostic properties of a nonmydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no or mild DR (ETDRS levels ≤ 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with κ = 0.79 for DR and 0.73 for CSME for grader 1, and κ = 0.77 (DR) and 0.77 (CSME) for grader 2. Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties.

  20. Visual Scan Paths and Recognition of Facial Identity in Autism Spectrum Disorder and Typical Development

    Science.gov (United States)

    Wilson, C. Ellie; Palermo, Romina; Brock, Jon

    2012-01-01

    Background Previous research suggests that many individuals with autism spectrum disorder (ASD) have impaired facial identity recognition, and also exhibit abnormal visual scanning of faces. Here, two hypotheses accounting for an association between these observations were tested: i) better facial identity recognition is associated with increased gaze time on the Eye region; ii) better facial identity recognition is associated with increased eye-movements around the face. Methodology and Principal Findings Eye-movements of 11 children with ASD and 11 age-matched typically developing (TD) controls were recorded whilst they viewed a series of faces, and then completed a two alternative forced-choice recognition memory test for the faces. Scores on the memory task were standardized according to age. In both groups, there was no evidence of an association between the proportion of time spent looking at the Eye region of faces and age-standardized recognition performance, thus the first hypothesis was rejected. However, the ‘Dynamic Scanning Index’ – which was incremented each time the participant saccaded into and out of one of the core-feature interest areas – was strongly associated with age-standardized face recognition scores in both groups, even after controlling for various other potential predictors of performance. Conclusions and Significance In support of the second hypothesis, results suggested that increased saccading between core-features was associated with more accurate face recognition ability, both in typical development and ASD. Causal directions of this relationship remain undetermined. PMID:22666378

  1. Eye Movement Disorders

    Science.gov (United States)

    ... work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... in "crossed eyes" or "walleye." Nystagmus - fast, uncontrollable movements of the eyes, sometimes called "dancing eyes" Some ...

  2. Surgical retroperitoneoscopic and transperitoneoscopic access in varicocelectomy: duplex scan results in pediatric population.

    Science.gov (United States)

    Mancini, Stefano; Bulotta, Anna Lavinia; Molinaro, Francesco; Ferrara, Francesco; Tommasino, Giulio; Messina, Mario

    2014-12-01

    This is a retrospective study to compare duplex scan results of laparoscopic Palomo's technique through retroperitoneal and transperitoneal approach for varicocelectomy in children. We statistically analyzed recurrence, testicular volume growth and complications. Surgical intervention was performed utilizing transperitoneoscopic (group A) or retroperitoneoscopic access (group B). Duplex scan control was performed after 12 months (T1), after 2 years (T2) and the last one at 18 years old in most patients. Statistical analysis was performed using the t-test for parametric data. Differences in proportions were evaluated using χ2 or Fisher's exact test. We treated 120 children (age range 10-17 years) who presented an asymptomatic IV grade of reflux, Coolsaet 1, associated with a left testicular hypotrophy in 36.6% of the cases (44 patients). No post-operative complications were verified. Duplex scan exam showed an increase of left testicular growth in both groups, with complete hypotrophy disappear in patients in both groups after 24 months. Hydrocele, diagnosed clinically and confirmed with duplex scan, was the most frequent post-operative complication (22/120 cases; 18.3%). This study showed the importance of duplex scan at all steps of this vascular pathology in children, and that there is no significantly difference in results between the two surgical techniques except for hydrocele in transperitoneoscopic access. Copyright © 2014 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  3. Non-compact left ventricle/hypertrabeculated left ventricle

    International Nuclear Information System (INIS)

    Restrepo, Gustavo; Castano, Rafael; Marmol, Alejandro

    2005-01-01

    Non-compact left ventricle/hypertrabeculated left ventricle is a myocardiopatie produced by an arrest of the normal left ventricular compaction process during the early embryogenesis. It is associated to cardiac anomalies (congenital cardiopaties) as well as to extracardial conditions (neurological, facial, hematologic, cutaneous, skeletal and endocrinological anomalies). This entity is frequently unnoticed, being diagnosed only in centers with great experience in the diagnosis and treatment of myocardiopathies. Many cases of non-compact left ventricle have been initially misdiagnosed as hypertrophic myocardiopatie, endocardial fibroelastosis, dilated cardiomyopatie, restrictive cardiomyopathy and endocardial fibrosis. It is reported the case of a 74 years old man with a history of chronic arterial hypertension and diabetes mellitus, prechordial chest pain and mild dyspnoea. An echocardiogram showed signs of non-compact left ventricle with prominent trabeculations and deep inter-trabecular recesses involving left ventricular apical segment and extending to the lateral and inferior walls. Literature on this topic is reviewed

  4. Acupuncture for dry eye: a randomised controlled trial protocol

    Directory of Open Access Journals (Sweden)

    Kim Ae-Ran

    2009-12-01

    Full Text Available Abstract Background Dry eye is usually managed by conventional medical interventions such as artificial tears, anti-inflammatory drugs and surgical treatment. However, since dry eye is one of the most frequent ophthalmologic disorders, safer and more effective methods for its treatment are necessary, especially for vulnerable patients. Acupuncture has been widely used to treat patients with dry eye. Our aim is to evaluate the effectiveness and safety of acupuncture for this condition. Methods/Design A randomised, patient-assessor blinded, sham (non-acupuncture point, shallow acupuncture controlled study was established. Participants allocated to verum acupuncture and sham acupuncture groups will be treated three times weekly for three weeks for a total of nine sessions per participant. Seventeen points (GV23; bilateral BL2, GB4, TE23, Ex1 (Taiyang, ST1 and GB20; and left SP3, LU9, LU10 and HT8 for men, right for women have been selected for the verum acupuncture; for the sham acupuncture, points have been selected that do not coincide with a classical acupuncture point and that are located close to the verum points, except in the case of the rim of the eye. Ocular surface disease index, tear film breakup time, the Schirmer I test, medication quantification scale and general assessment of improvement will be used as outcome variables for evaluating the effectiveness of acupuncture. Safety will also be assessed at every visit. Primary and secondary outcomes will be assessed four weeks after screening. All statistical analyses will be performed using analysis of covariance. Discussion The results of this trial will be used as a basis for clarifying the efficacy of acupuncture for dry eye. Trial registration ClinicalTrials.gov NCT00969280.

  5. EEG and Eye Tracking Signatures of Target Encoding during Structured Visual Search

    Directory of Open Access Journals (Sweden)

    Anne-Marie Brouwer

    2017-05-01

    Full Text Available EEG and eye tracking variables are potential sources of information about the underlying processes of target detection and storage during visual search. Fixation duration, pupil size and event related potentials (ERPs locked to the onset of fixation or saccade (saccade-related potentials, SRPs have been reported to differ dependent on whether a target or a non-target is currently fixated. Here we focus on the question of whether these variables also differ between targets that are subsequently reported (hits and targets that are not (misses. Observers were asked to scan 15 locations that were consecutively highlighted for 1 s in pseudo-random order. Highlighted locations displayed either a target or a non-target stimulus with two, three or four targets per trial. After scanning, participants indicated which locations had displayed a target. To induce memory encoding failures, participants concurrently performed an aurally presented math task (high load condition. In a low load condition, participants ignored the math task. As expected, more targets were missed in the high compared with the low load condition. For both conditions, eye tracking features distinguished better between hits and misses than between targets and non-targets (with larger pupil size and shorter fixations for missed compared with correctly encoded targets. In contrast, SRP features distinguished better between targets and non-targets than between hits and misses (with average SRPs showing larger P300 waveforms for targets than for non-targets. Single trial classification results were consistent with these averages. This work suggests complementary contributions of eye and EEG measures in potential applications to support search and detect tasks. SRPs may be useful to monitor what objects are relevant to an observer, and eye variables may indicate whether the observer should be reminded of them later.

  6. Evaluation of a new irradiation left breast method in the inhalation phase

    International Nuclear Information System (INIS)

    Silva, Laura E. da; Gullo, Rafael G.; Ferreira, Diogo A.V.; Silva, Leonardo P. da

    2016-01-01

    Radiation therapy is the primary therapeutic approach to breast cancer and involves significant exposure of heart and lungs, especially in cases of left breast. The implementation of a methodology to reduce the dose in these sites is important to ensure better quality of life to the patient. This work aims reduced heart and lung dose when performing the radiotherapy planning considering only the inhalation phase. Three patients with breast left present were scanning with CT during free breathing and respiratory monitoring and the planning has done on both images series. The results showed a reduction in mean heart dose of 53% on average. As for lung volumes, was obtained a mean reduction of 44.6% and 51% of the left lung which received 10 Gy and 20 Gy, respectively. This study showed that the use of the respiratory gating radiotherapy in the left breast in inhalation phase can reduce heart and lung doses. (author)

  7. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients

    Science.gov (United States)

    Stonecipher, Karl G; Chia, Jenny; Onyenwenyi, Ahunna; Villanueva, Linda; Hollander, David A

    2013-01-01

    Background Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis®) use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Methods Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. Results The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40–69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008–2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months’ supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Conclusion Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies. PMID:24179335

  8. Primary laryngeal tuberculosis mimicking laryngeal carcinoma: CT scan features

    International Nuclear Information System (INIS)

    El Kettani, N Ech-Cherif; El Hassani, MR; Chakir, N; Jiddane, M

    2010-01-01

    Laryngeal tuberculosis is a rare disease. It is almost always associated with pulmonary tuberculosis. It occurs generally in adults without BCG vaccination or in cases of the acquired immune deficiency syndrome. On laryngoscopy and imaging, it often simulates laryngeal carcinoma, and confirmation is always histological. We report the case of a 36-year-old man who presented to our hospital with dysphonia and dysphagia. Laryngoscopy revealed a lesion of the left vocal cord and the ventricular strip. CT scan found focal, regular thickening of the left vocal cord, associated with irregular thickening of the posterior laryngeal wall. A biopsy confirmed the diagnosis of tuberculosis

  9. About the Eye

    Medline Plus

    Full Text Available ... for Kids >> About the Eye Listen All About Vision About the Eye Ask a Scientist Video Series ... Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun ...

  10. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  11. Uncovering the cognitive processes underlying mental rotation: an eye-movement study.

    Science.gov (United States)

    Xue, Jiguo; Li, Chunyong; Quan, Cheng; Lu, Yiming; Yue, Jingwei; Zhang, Chenggang

    2017-08-30

    Mental rotation is an important paradigm for spatial ability. Mental-rotation tasks are assumed to involve five or three sequential cognitive-processing states, though this has not been demonstrated experimentally. Here, we investigated how processing states alternate during mental-rotation tasks. Inference was carried out using an advanced statistical modelling and data-driven approach - a discriminative hidden Markov model (dHMM) trained using eye-movement data obtained from an experiment consisting of two different strategies: (I) mentally rotate the right-side figure to be aligned with the left-side figure and (II) mentally rotate the left-side figure to be aligned with the right-side figure. Eye movements were found to contain the necessary information for determining the processing strategy, and the dHMM that best fit our data segmented the mental-rotation process into three hidden states, which we termed encoding and searching, comparison, and searching on one-side pair. Additionally, we applied three classification methods, logistic regression, support vector model and dHMM, of which dHMM predicted the strategies with the highest accuracy (76.8%). Our study did confirm that there are differences in processing states between these two of mental-rotation strategies, and were consistent with the previous suggestion that mental rotation is discrete process that is accomplished in a piecemeal fashion.

  12. Diabetic Eye Disease

    Science.gov (United States)

    ... Disease, & Other Dental Problems Diabetes & Sexual & Urologic Problems Diabetic Eye Disease What is diabetic eye disease? Diabetic eye disease is a group ... eye diseases that can threaten your sight are Diabetic retinopathy The retina is the inner lining at ...

  13. [Turning the head, an unusual mechanism to compensate for diplopia caused by abduction restriction of one eye

    NARCIS (Netherlands)

    Kappelle, A.C.; Schelhaas, H.J.; Pasman, J.W.; Bloem, B.R.

    2004-01-01

    A 59-year-old-man visited the neurological outpatient clinic because of a leftward rotation of his head for the last 8 months. This head deviation turned out to represent a compensatory mechanism to alleviate diplopia that resulted from an abduction restriction of his left eye. By turning his head

  14. The size of thyroid gland measured by scan

    International Nuclear Information System (INIS)

    Choe, K. O.; Choe, Y. K.; Park, C. Y.; Choi, B. S.

    1973-01-01

    Normal size of thyroid gland in Korean male and female were aimed to study through color scanning using radioactive materials. The measurement of the size of thyroid gland is necessary not only for standardization of Korean subjects but also to the dose determination of radioactive iodine treatment and evaluation of thyroid disease. There had been no available data in regarding Korean euthyroid size in literature. In 119 subjects from the age of 19 years to 60 tears, who have normal thyroid function and no history of any thyroid disorder, the length, the width and the area of thyroid gland were measured in scan images. The weight of thyroid gland was calculated by Allen-Goodwin's formula. The thyroid scan was obtained by Picker Color Magna-Scanner, in 24 hours after ingestion of 50μCi sodium iodide 1-131. Results; In males, 16 subjects among 119 cases, the mean values were as following: length-5.1 cm, width-2.5 cm, area-9.1 cm 2 , weight-14.7 gr in right lobe, length-4.7 cm, width-2.3 cm, area-7.6 cm 2 , weight-11.1 gr in left lobe, total area-16.7 cm 2 , and total weight-25.8 gr. In females, 103 subjects among 119 cases, the mean values were as following: length-5.1 cm, width-2.4 cm, area-9.4 cm 2 , weight-15.2 gr in the right lobe, length-4.6 cm, width-2.2 cm, area-7.9 cm 2 , weight-11.6 gr in left lobe, total area-17.3 cm 2 , total weight-26.8 gr. The right lobe was larger in the above mean values of size than the left: 11% longer in length, 8% wider in width, 18% broader in area and 30% heavier in weight in mean values. The difference of sizes between two lobes was statistically significant. There was no significant difference comparison with English written literature

  15. Retinal image quality and visual stimuli processing by simulation of partial eye cataract

    Science.gov (United States)

    Ozolinsh, Maris; Danilenko, Olga; Zavjalova, Varvara

    2016-10-01

    Visual stimuli were demonstrated on a 4.3'' mobile phone screen inside a "Virtual Reality" adapter that allowed separation of the left and right eye visual fields. Contrast of the retina image thus can be controlled by the image on the phone screen and parallel to that at appropriate geometry by the AC voltage applied to scattering PDLC cell inside the adapter. Such optical pathway separation allows to demonstrate to both eyes spatially variant images, that after visual binocular fusion acquire their characteristic indications. As visual stimuli we used grey and different color (two opponent components to vision - red-green in L*a*b* color space) spatially periodical stimuli for left and right eyes; and with spatial content that by addition or subtraction resulted as clockwise or counter clockwise slanted Gabor gratings. We performed computer modeling with numerical addition or subtraction of signals similar to processing in brain via stimuli input decomposition in luminance and color opponency components. It revealed the dependence of the perception psychophysical equilibrium point between clockwise or counter clockwise perception of summation on one eye image contrast and color saturation, and on the strength of the retinal aftereffects. Existence of a psychophysical equilibrium point in perception of summation is only in the presence of a prior adaptation to a slanted periodical grating and at the appropriate slant orientation of adaptation grating and/or at appropriate spatial grating pattern phase according to grating nods. Actual observer perception experiments when one eye images were deteriorated by simulated cataract approved the shift of mentioned psychophysical equilibrium point on the degree of artificial cataract. We analyzed also the mobile devices stimuli emission spectra paying attention to areas sensitive to macula pigments absorption spectral maxima and blue areas where the intense irradiation can cause in abnormalities in periodic melatonin

  16. Effectiveness of hormone therapy for treating dry eye syndrome in postmenopausal women: a randomized trial.

    Science.gov (United States)

    Piwkumsribonruang, Narongchai; Somboonporn, Woraruk; Luanratanakorn, Patanaree; Kaewrudee, Srinaree; Tharnprisan, Piangjit; Soontrapa, Sugree

    2010-06-01

    The efficacy of hormone therapy (HT) on dry eye syndrome remains debatable. To study the efficacy of HT on dry eye syndrome. A randomized controlled, double blind, parallel group, community-based study in 42 post-menopausal patients was conducted. The patients had dry eye syndrome and were not taking any medications. They were assigned to one of two groups. Group A comprised 21 patients given transdermal 17 beta-estradiol (50 mg/day) and medroxy progesterone acetate (2.5 mg/day) continuously for three months and group B comprised 21 patients given both transdermal and oral placebo. Participants in the study were included for final analysis. The improvement of dry eye symptoms were measured by visual analog scale, tear secretion, intraocular pressure, corneal thickness, and tear breakup time determined before treatment and at 6 and 12 weeks of treatment. At 12 weeks, the number of patients who reported improvement of dry eye symptoms was greater in the HT group than that in the placebo group. However, the difference was not statistically significant (RR 0.25, 95% CI 0.04-2.80 and 0.60, 95% CI 0.33-2.03 in right and left eye, respectively). For other parameters, there was no significant difference between the two groups. According to the present study, there is no strong evidence to support the use of HT for treating dry eye syndrome. The limited number of participants included in the present study may have contributed to the insignificant effects.

  17. An unusual case of total ophthalmoplegia

    Directory of Open Access Journals (Sweden)

    Chowdhury Ravindra

    2009-01-01

    Full Text Available An eight-year-old male child presented with drooping of the left eyelid with a history of penetrating injury of hard palate by an iron spoon seven days ago, which had already been removed by the neurosurgeon as the computed tomography scan revealed a spoon in the left posterior ethmoid and sphenoid bone penetrating into the middle cranial fossa. On examination, visual acuity was 20/20 in each eye and left eye showed total ophthalmoplegia. Oral cavity revealed a hole in the left lateral part of the hard palate. We managed the case with tapering dose of systemic prednisolone. The total ophthalmoplegia was markedly improved in one month. Cases of foreign bodies in the orbit with intracranial extension are not unusual, but the path this foreign body traveled through the hard palate without affecting the optic nerve, internal carotid artery or cavernous sinus makes an interesting variation.

  18. Trunk- and head-centred spatial coordinates do not affect free-viewing perceptual asymmetries.

    Science.gov (United States)

    Nicholls, Michael E R; Mattingley, Jason B; Bradshaw, John L; Krins, Phillip W

    2003-11-01

    Turning the trunk or head to the left can reduce the severity of leftward neglect. This study sought to determine whether turning the trunk or head to the right would reduce pseudoneglect: A phenomenon where normal participants underestimate the rightward features of a stimulus. Participants made luminance judgements of two mirror-reversed greyscales stimuli. A preference for selecting the stimulus dark on the left was found. The effect of trunk-centred coordinates was examined in Expt. 1 by facing the head toward the display and turning the trunk to the left, right or toward the display. Head-centred coordinates were examined in Expt. 2 by directing the eyes toward the display and then turning the head and trunk. No effect of rotation was observed. It was concluded that the leftward bias for the greyscales task could be based on an object-centred attentional bias or left-to-right eye scanning habits.

  19. Pulmonary scanning: quantitative evaluation of pulmonary arterial flow

    Energy Technology Data Exchange (ETDEWEB)

    Papaleo Netto, M; Fujioka, T [Sao Paulo Univ. (Brazil). Faculdade de Medicina; Dias Neto, A; Carvalho, N [Sao Paulo Univ. (Brazil). Centro de Medicina Nuclear

    1974-01-01

    From ten normal subjects of both sexes, the quantitative regional blood flow of the pulmonary artery was evaluated using scanning with macroaggregated radio-iodinated (/sup 131/I) albumin. It was possible to conclude that: the digital recording of data (counts/cm/sup 2/), from any particular area of interest, is the best method for this evaluation; the lung, even being a thick organ, can be well studied by quantitative scanning, since its structure doesn't hinder the passage of radiations because it is covered only by the thoracic wall; scanning can be used to evaluate regional perfusion of the pulmonary artery, based on the proportionality between density of aggregates and blood flux in the different areas; the concentration of macroaggregates on the lung's superior section never reaches more than 40% of the radioactivity of the whole lung; there is no significant difference between left and right lungs, concerning the relationship between radioactivity on the superior section and the total area and quantitative analysis of pulmonary artery flow by means of scanning is a possible, reliable, and safe technique, without distress for the patient.

  20. Pulmonary scanning: quantitative evaluation of pulmonary arterial flow

    International Nuclear Information System (INIS)

    Papaleo Netto, M.; Fujioka, T.; Dias Neto, A.; Carvalho, N.

    1974-01-01

    From ten normal subjects of both sexes, the quantitative regional blood flow of the pulmonary artery was evaluated using scanning with macroaggregated radio-iodinated ( 131 I) albumin. It was possible to conclude that: the digital recording of data (counts/cm 2 ), from any particular area of interest, is the best method for this evaluation; the lung, even being a thick organ, can be well studied by quantitative scanning, since its structure doesn't hinder the passage of radiations because it is covered only by the thoracic wall; scanning can be used to evaluate regional perfusion of the pulmonary artery, based on the proportionality between density of aggregates and blood flux in the different areas; the concentration of macroaggregates on the lung's superior section never reaches more than 40% of the radioactivity of the whole lung; there is no significant difference between left and right lungs, concerning the relationship between radioactivity on the superior section and the total area and quantitative analysis of pulmonary artery flow by means of scanning is a possible, reliable and safe technique, without distress for the patient [pt

  1. Forensic Scanning Electron Microscope

    Science.gov (United States)

    Keeley, R. H.

    1983-03-01

    The scanning electron microscope equipped with an x-ray spectrometer is a versatile instrument which has many uses in the investigation of crime and preparation of scientific evidence for the courts. Major applications include microscopy and analysis of very small fragments of paint, glass and other materials which may link an individual with a scene of crime, identification of firearms residues and examination of questioned documents. Although simultaneous observation and chemical analysis of the sample is the most important feature of the instrument, other modes of operation such as cathodoluminescence spectrometry, backscattered electron imaging and direct x-ray excitation are also exploited. Marks on two bullets or cartridge cases can be compared directly by sequential scanning with a single beam or electronic linkage of two instruments. Particles of primer residue deposited on the skin and clothing when a gun is fired can be collected on adhesive tape and identified by their morphology and elemental composition. It is also possible to differentiate between the primer residues of different types of ammunition. Bullets may be identified from the small fragments left behind as they pass through the body tissues. In the examination of questioned documents the scanning electron microscope is used to establish the order in which two intersecting ink lines were written and to detect traces of chemical markers added to the security inks on official documents.

  2. Pyrophosphate scan of the temporarily ischemized dog myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.; Veverkova, O.

    1981-12-01

    In 9 dogs a transient myocardial ischemia was provoked using complete occlusion of the ramus interventricularis anterior of the left coronary artery. The occlusion was removed after 5, 10 or 15 min. Four hrs after removal of the occlusion a scan of the myocardium was carried out using sup(99m)Tc-labelled pyrophosphate. In 7 out of 9 dogs under study the scan was markedly positive, in 2 dogs negative. ECG demonstrated ischemic changes practically in all dogs; the changes became normal after removal of the occlusion, namely in 5 to 35 min. The histological examination of the tissue demonstrated in all 9 dogs only a slight impairment of the myocardium.

  3. What Is Dry Eye?

    Science.gov (United States)

    ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ...

  5. Left regular bands of groups of left quotients

    International Nuclear Information System (INIS)

    El-Qallali, A.

    1988-10-01

    A semigroup S which has a left regular band of groups as a semigroup of left quotients is shown to be the semigroup which is a left regular band of right reversible cancellative semigroups. An alternative characterization is provided by using spinned products. These results are applied to the case where S is a superabundant whose set of idempotents forms a left normal band. (author). 13 refs

  6. In vivo retinal imaging for fixational eye motion detection using a high-speed digital micromirror device (DMD)-based ophthalmoscope.

    Science.gov (United States)

    Vienola, Kari V; Damodaran, Mathi; Braaf, Boy; Vermeer, Koenraad A; de Boer, Johannes F

    2018-02-01

    Retinal motion detection with an accuracy of 0.77 arcmin corresponding to 3.7 µm on the retina is demonstrated with a novel digital micromirror device based ophthalmoscope. By generating a confocal image as a reference, eye motion could be measured from consecutively measured subsampled frames. The subsampled frames provide 7.7 millisecond snapshots of the retina without motion artifacts between the image points of the subsampled frame, distributed over the full field of view. An ophthalmoscope pattern projection speed of 130 Hz enabled a motion detection bandwidth of 65 Hz. A model eye with a scanning mirror was built to test the performance of the motion detection algorithm. Furthermore, an in vivo motion trace was obtained from a healthy volunteer. The obtained eye motion trace clearly shows the three main types of fixational eye movements. Lastly, the obtained eye motion trace was used to correct for the eye motion in consecutively obtained subsampled frames to produce an averaged confocal image correct for motion artefacts.

  7. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  8. Your Eyes

    Science.gov (United States)

    ... away? If you guessed the eye, you're right! Your eyes are at work from the moment you wake up to the ... the eye is seeing. A Muscle Makes It Work The lens is suspended in ... of the lens. That's right — the lens actually changes shape right inside your ...

  9. Greek mythology: the eye, ophthalmology, eye disease, and blindness.

    Science.gov (United States)

    Trompoukis, Constantinos; Kourkoutas, Dimitrios

    2007-06-01

    In distant eras, mythology was a form of expression used by many peoples. A study of the Greek myths reveals concealed medical knowledge, in many cases relating to the eye. An analysis was made of the ancient Greek texts for mythological references relating to an understanding of vision, visual abilities, the eye, its congenital and acquired abnormalities, blindness, and eye injuries and their treatment. The Homeric epics contain anatomical descriptions of the eyes and the orbits, and an elementary knowledge of physiology is also apparent. The concept of the visual field can be seen in the myth of Argos Panoptes. Many myths describe external eye disease ("knyzosis"), visual disorders (amaurosis), and cases of blinding that, depending on the story, are ascribed to various causes. In addition, ocular motility abnormalities, congenital anomalies (cyclopia), injuries, and special treatments, such as the "licking" method, are mentioned. The study of mythological references to the eye reveals reliable medical observations of the ancient Greeks, which are concealed within the myths.

  10. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  11. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    International Nuclear Information System (INIS)

    Rehani, M.

    2015-01-01

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  12. Health claims database study of cyclosporine ophthalmic emulsion treatment patterns in dry eye patients

    Directory of Open Access Journals (Sweden)

    Stonecipher KG

    2013-10-01

    Full Text Available Karl G Stonecipher,1 Jenny Chia,2 Ahunna Onyenwenyi,2 Linda Villanueva,2 David A Hollander2 1TLC Laser Eye Centers, Greensboro, NC, 2Allergan, Inc., Irvine, CA, USA Background: Dry eye is a multifactorial, symptomatic disease associated with ocular surface inflammation and tear film hyperosmolarity. This study was designed to assess patterns of topical cyclosporine ophthalmic emulsion 0.05% (Restasis® use in dry eye patients and determine if there were any differences in use based on whether dry eye is physician-coded as a primary or nonprimary diagnosis. Methods: Records for adult patients with a diagnosis of dry eye at an outpatient visit from January 1, 2008 to December 31, 2009 were selected from Truven Health MarketScan® Research Databases. The primary endpoint was percentage of patients with at least one primary versus no primary dry eye diagnosis who filled a topical cyclosporine prescription. Data analyzed included utilization of topical corticosteroids, oral tetracyclines, and punctal plugs. Results: The analysis included 576,416 patients, accounting for 875,692 dry eye outpatient visits: 74.7% were female, 64.2% were ages 40-69 years, and 84.4% had at least one primary dry eye diagnosis. During 2008–2009, 15.9% of dry eye patients with a primary diagnosis versus 6.5% with no primary diagnosis filled at least one cyclosporine prescription. For patients who filled at least one prescription, the mean months’ supply of cyclosporine filled over 12 months was 4.44. Overall, 33.9% of dry eye patients filled a prescription for topical cyclosporine, topical corticosteroid, or oral tetracycline over 2 years. Conclusion: Patients with a primary dry eye diagnosis were more likely to fill a topical cyclosporine prescription. Although inflammation is key to the pathophysiology of dry eye, most patients seeing a physician for dry eye may not receive anti-inflammatory therapies. Keywords: corticosteroids, cyclosporine, dry eye syndromes

  13. Extraction of left ventricular myocardial mass from dynamic 11C-acetate PET

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    Background: Dynamic 11C-acetate PET is used to quantify oxygen metabolism, which is used to calculate left ventricular (LV) myocardial efficiency, an early marker of heart failure. This requires estimation of LV myocardial mass and is typically derived from a separate cardiovascular magnetic...... resonance (CMR) scan. The aim of this study was to explore the feasibility of estimating myocardial mass directly from a dynamic 11C-acetate PET scan. Methods: 21 subjects underwent a 27-min 11C-acetate PET scan on a Siemens Biograph TruePoint 64 PET/CT scanner. In addition, 10 subjects underwent a dynamic...... 11C-acetate 27-min PET scan on a GE Discovery ST PET/CT scanner. Parametric images of uptake rate K1 and both arterial (VA) and venous (VV) spillover fractions were generated using a basis function implementation of the standard single tissue compartment model using non-gated dynamic data. The LV...

  14. Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC).

    Science.gov (United States)

    Dada, Tanuj; Aggarwal, A; Bali, S J; Sharma, A; Shah, B M; Angmo, D; Panda, A

    2013-01-01

    Myopia presents a significant challenge to the ophthalmologist as myopic discs are often large, tilted, with deep cups and have a thinner neuroretinal rim all of which may mimic glaucomatous optic nerve head changes causing an error in diagnosis. To evaluate the retinal fiber layer (RNFL) thickness in low, moderate and high myopia using scanning laser polarimetry with variable corneal compensation (GDxVCC). One hundred eyes of 100 emmetropes, 30 eyes of low myopes (0 to - 4 D spherical equivalent(SE), 45 eyes with moderate myopia (- 4 to - 8D SE), and 30 eyes with high myopia (- 8 to - 15D SE) were subjected to retinal nerve fiber layer assessment using the scanning laser polarimetry (GDxVCC) in all subjects using the standard protocol. Subjects with IOP > 21 mm Hg, optic nerve head or visual field changes suggestive of glaucoma were excluded from the study. The major outcome parameters were temporal-superior-nasal-inferiortemporal (TSNIT) average, the superior and inferior average and the nerve fibre indicator (NFI). The TSNIT average (p = 0.009), superior (p = 0.001) and inferior average (p = 0.008) were significantly lower; the NFI was higher (P less than 0.001) in moderate myopes as compared to that in emmetropes. In high myopia the RNFL showed supranormal values; the TSNIT average, superior and inferior average was significantly higher(p less than 0.001) as compared to that in emmetropes. The RNFL measurements on scanning laser polarimetry are affected by the myopic refractive error. Moderate myopes show a significant thinning of the RNFL. In high myopia due to peripapillary chorioretinal atrophy and contribution of scleral birefringence, the RNFL values are abnormally high. These findings need to be taken into account while assessing and monitoring glaucoma damage in moderate to high myopes on GDxVCC. © NEPjOPH.

  15. Scanning patterns of faces do not explain impaired emotion recognition in Huntington Disease: Evidence for a high level mechanism

    Directory of Open Access Journals (Sweden)

    Marieke evan Asselen

    2012-02-01

    Full Text Available Previous studies in patients with amygdala lesions suggested that deficits in emotion recognition might be mediated by impaired scanning patterns of faces. Here we investigated whether scanning patterns also contribute to the selective impairment in recognition of disgust in Huntington disease (HD. To achieve this goal, we recorded eye movements during a two-alternative forced choice emotion recognition task. HD patients in presymptomatic (n=16 and symptomatic (n=9 disease stages were tested and their performance was compared to a control group (n=22. In our emotion recognition task, participants had to indicate whether a face reflected one of six basic emotions. In addition, and in order to define whether emotion recognition was altered when the participants were forced to look at a specific component of the face, we used a second task where only limited facial information was provided (eyes/mouth in partially masked faces. Behavioural results showed no differences in the ability to recognize emotions between presymptomatic gene carriers and controls. However, an emotion recognition deficit was found for all 6 basic emotion categories in early stage HD. Analysis of eye movement patterns showed that patient and controls used similar scanning strategies. Patterns of deficits were similar regardless of whether parts of the faces were masked or not, thereby confirming that selective attention to particular face parts is not underlying the deficits. These results suggest that the emotion recognition deficits in symptomatic HD patients cannot be explained by impaired scanning patterns of faces. Furthermore, no selective deficit for recognition of disgust was found in presymptomatic HD patients.

  16. NEURO-OPHTHALMOLOGY

    African Journals Online (AJOL)

    headache of 2 years duration and visual loss left eye (LE). She was ... perimetry confirmed a right homonymous hemianopia and Cranial CT scan showed a suprasellar ... Magnetic resonance imaging brain was ordered and neurosurgery ... as a function of decibel sensitivity loss on automated static perimetry. Implications ...

  17. Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy

    International Nuclear Information System (INIS)

    Theerakulpisut, Daris; Chotipanich, Chanisa

    2016-01-01

    Myocardial perfusion single photon emission computed tomography (SPECT) is a powerful test of evaluation for coronary artery disease, but subdiaphragmatic radiotracer activity often interferes with the interpretation of inferior wall findings. This study aims to evaluate the effectiveness of using software elimination of the subdiaphragmatic activity for the assessment of its efficacy in the correctness of image interpretation and the overall image quality of myocardial perfusion scintigraphy (MPS). MPS studies from January 2010 to October 2012 at our institution were reviewed. Thirty-two SPECT studies were included, all of which had significant subdiaphragmatic activity in the first scan and needed to be delayed to let the activity clear. Each scan was interpreted by using semiquantitative scoring in 17 segments according to the degree of radiotracer uptake. The first scan, which had interfering activity, was manipulated by masking out the unwanted activity with software native to our image processing software suite. The manipulated images were then compared with delayed images of the same patient, of which the subdiaphragmatic activity was spontaneously cleared with time. The first scan masked by software correlated with the delayed scan for myocardial regions supplied by the left circumflex (LCx) and right coronary artery (RCA), but not the left anterior descending (LAD). However, the quality of the masked scans was perceived by the observer to be better in terms of quality and ease of interpretation. Using software to mask out unwanted subdiaphragmatic activity has no detrimental effect on the interpretation of MPS images when compared with delayed scanning, but it can improve subjective scan quality and ease of interpretation

  18. Atherosclerotic plaque in the left carotid artery is more vulnerable than in the right.

    Science.gov (United States)

    Selwaness, Mariana; van den Bouwhuijsen, Quirijn; van Onkelen, Robbert S; Hofman, Albert; Franco, Oscar H; van der Lugt, Aad; Wentzel, Jolanda J; Vernooij, Meike

    2014-11-01

    Ischemic stroke is more often diagnosed in the left hemisphere than in the right. It is unknown whether this asymmetrical prevalence relates to differences in carotid atherosclerosis. We compared atherosclerotic plaque prevalence, severity, and composition between left and right carotid arteries. In a population-based cohort, carotid MRI scanning was performed in 1414 stroke-free participants (≥45 years). Using a multisequence MRI protocol, we assessed the prevalence, stenosis, and thickness of the plaque and its predominant component (ie, lipid core, intraplaque hemorrhage, calcification, or fibrous tissue in each carotid artery). Differences between left and right side were tested using paired t tests, McNemar test and Generalized Estimating Equation analyses. The majority (85%) of the participants had bilateral carotid plaques. Unilateral plaques were twice more prevalent on the left than on the right side (67% versus 33%; Pthe left (3.1±1.2 versus 2.9±1.3 mm; Pthe left (9.1 versus 5.9%; Pthe right (37.4 versus 31.6% at the left; Pright-sided plaques, which are more calcified and therefore considered more stable. © 2014 American Heart Association, Inc.

  19. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    Directory of Open Access Journals (Sweden)

    Xinjie Mao

    Full Text Available To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor.Twenty-eight adult subjects (32 pseudophakic eyes having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR and intraclass correlation coefficient (ICC were calculated.Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951.The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  20. CT evaluation of decrease in attenuation in the superior segment of the left lower lobe

    International Nuclear Information System (INIS)

    Inaoka, Tsutomu; Takahashi, Koji; Ono, Hidetoshi

    2003-01-01

    We occasionally see decrease in attenuation in the superior segment of the left lower lobe on normal chest CT and notice that this finding could be seen in elder population. Then, we assessed the frequency, age distribution and cause of decrease in attenuation in the superior segment of the left lower lobe. Chest CT scans of 246 patients without lung or cardiac disorders were retrospectively reviewed. Segmental low attenuation area in the superior segment of the left lower lobe was identified in 12 patients (4.9%), which were 65-92 years old with mean age of 77.2 years old. In all of them, chest CT demonstrated that the tortuous descending aorta compressed directly the superior segmental bronchus of the left lower lobe. It is concluded that the lateral tortuousity of the descending aorta could cause decrease in attenuation in the superior segment of the left lower lobe. (author)

  1. Cornea and anterior eye assessment with placido-disc keratoscopy, slit scanning evaluation topography and scheimpflug imaging tomography.

    Science.gov (United States)

    Martin, Raul

    2018-03-01

    Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple and several devices and technologies allow to explore and to manage patients. The purpose of this special issue is to present and also to update in the evaluation of cornea and ocular surface and this second part, reviews a description of the corneal topography and tomography techniques, providing updated information of the clinical recommendations of these techniques in eye care practice. Placido-based topographers started an exciting anterior corneal surface analysis that allows the development of current corneal tomographers that provide a full three-dimensional reconstruction of the cornea including elevation, curvature, and pachymetry data of anterior and posterior corneal surfaces. Although, there is not an accepted reference standard technology for corneal topography description and it is not possible to determine which device produces the most accurate topographic measurements, placido-based topographers are a valuable technology to be used in primary eye care and corneal tomograhers expanding the possibilities to explore cornea and anterior eye facilitating diagnosis and follow-up in several situations, raising patient follow-up, and improving the knowledge regarding to the corneal anatomy. Main disadvantages of placido-based topographers include the absence of information about the posterior corneal surface and limited corneal surface coverage without data from the para-central and/or peripheral corneal surface. However, corneal tomographers show repeatable anterior and posterior corneal surfaces measurements, providing full corneal thickness data improving cornea, and anterior surface assessment. However, differences between devices suggest that they are not interchangeable in clinical practice.

  2. Comparison of Optical Coherence Tomography and Scanning Laser Polarimetry Measurements in Patients with Multiple Sclerosis

    Science.gov (United States)

    Quelly, Amanda; Cheng, Han; Laron, Michal; Schiffman, Jade S.; Tang, Rosa A.

    2010-01-01

    Purpose To compare optical coherence tomography (OCT) and scanning laser polarimetry (GDx) measurements of the retinal nerve fiber layer (RNFL) in multiple sclerosis (MS) patients with and without optic neuritis (ON). Methods OCT and GDx were performed on 68 MS patients. Qualifying eyes were divided into two groups: 51 eyes with an ON history ≥ 6 months prior (ON eyes), and 65 eyes with no history of ON (non-ON eyes). Several GDx and OCT parameters and criteria were used to define an eye as abnormal, for example, GDx nerve fiber indicator (NFI) above 20 or 30, OCT average RNFL thickness and GDx temporal-superior-nasal-inferior-temporal average (TSNIT) below 5% or 1% of the instruments’ normative database. Agreement between OCT and GDx parameters was reported as percent of observed agreement, along with the AC1 statistic. Linear regression analyses were used to examine the relationship between OCT average RNFL thickness and GDx NFI and TSNIT. Results All OCT and GDx measurements showed significantly more RNFL damage in ON than in non-ON eyes. Agreement between OCT and GDx parameters ranged from 69–90% (AC1 0.37–0.81) in ON eyes, and 52–91% (AC1 = 0.21–0.90) in non-ON eyes. Best agreement was observed between OCT average RNFL thickness (P 30) in ON eyes (90%, AC1 = 0.81), and between OCT average RNFL thickness (P < 0.01) and GDx TSNIT average (P < 0.01) in non-ON eyes (91%, AC1 = 0.90). In ON eyes, the OCT average RNFL thickness showed good linear correlation with NFI (R2 = 0.69, P < 0.0001) and TSNIT (R2 = 0.55, P < 0.0001). Conclusions OCT and GDx show good agreement and can be useful in detecting RNFL loss in MS/ON eyes. PMID:20495500

  3. Left, right, left, right, eyes to the front! Müller-Lyer bias in grasping is not a function of hand used, hand preferred or visual hemifield, but foveation does matter.

    Science.gov (United States)

    van der Kamp, John; de Wit, Matthieu M; Masters, Rich S W

    2012-04-01

    We investigated whether the control of movement of the left hand is more likely to involve the use of allocentric information than movements performed with the right hand. Previous studies (Gonzalez et al. in J Neurophys 95:3496-3501, 2006; De Grave et al. in Exp Br Res 193:421-427, 2009) have reported contradictory findings in this respect. In the present study, right-handed participants (N = 12) and left-handed participants (N = 12) made right- and left-handed grasps to foveated objects and peripheral, non-foveated objects that were located in the right or left visual hemifield and embedded within a Müller-Lyer illusion. They were also asked to judge the size of the object by matching their hand aperture to its length. Hand apertures did not show significant differences in illusory bias as a function of hand used, handedness or visual hemifield. However, the illusory effect was significantly larger for perception than for action, and for the non-foveated compared to foveated objects. No significant illusory biases were found for reach movement times. These findings are consistent with the two-visual system model that holds that the use of allocentric information is more prominent in perception than in movement control. We propose that the increased involvement of allocentric information in movements toward peripheral, non-foveated objects may be a consequence of more awkward, less automatized grasps of nonfoveated than foveated objects. The current study does not support the conjecture that the control of left-handed and right-handed grasps is predicated on different sources of information.

  4. Visual scanning and recognition of Chinese, Caucasian, and racially ambiguous faces: contributions from bottom-up facial physiognomic information and top-down knowledge of racial categories.

    Science.gov (United States)

    Wang, Qiandong; Xiao, Naiqi G; Quinn, Paul C; Hu, Chao S; Qian, Miao; Fu, Genyue; Lee, Kang

    2015-02-01

    Recent studies have shown that participants use different eye movement strategies when scanning own- and other-race faces. However, it is unclear (1) whether this effect is related to face recognition performance, and (2) to what extent this effect is influenced by top-down or bottom-up facial information. In the present study, Chinese participants performed a face recognition task with Chinese, Caucasian, and racially ambiguous faces. For the racially ambiguous faces, we led participants to believe that they were viewing either own-race Chinese faces or other-race Caucasian faces. Results showed that (1) Chinese participants scanned the nose of the true Chinese faces more than that of the true Caucasian faces, whereas they scanned the eyes of the Caucasian faces more than those of the Chinese faces; (2) they scanned the eyes, nose, and mouth equally for the ambiguous faces in the Chinese condition compared with those in the Caucasian condition; (3) when recognizing the true Chinese target faces, but not the true target Caucasian faces, the greater the fixation proportion on the nose, the faster the participants correctly recognized these faces. The same was true when racially ambiguous face stimuli were thought to be Chinese faces. These results provide the first evidence to show that (1) visual scanning patterns of faces are related to own-race face recognition response time, and (2) it is bottom-up facial physiognomic information that mainly contributes to face scanning. However, top-down knowledge of racial categories can influence the relationship between face scanning patterns and recognition response time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Visual scanning and recognition of Chinese, Caucasian, and racially ambiguous faces: Contributions from bottom-up facial physiognomic information and top-down knowledge of racial categories

    Science.gov (United States)

    Wang, Qiandong; Xiao, Naiqi G.; Quinn, Paul C.; Hu, Chao S.; Qian, Miao; Fu, Genyue; Lee, Kang

    2014-01-01

    Recent studies have shown that participants use different eye movement strategies when scanning own- and other-race faces. However, it is unclear (1) whether this effect is related to face recognition performance, and (2) to what extent this effect is influenced by top-down or bottom-up facial information. In the present study, Chinese participants performed a face recognition task with Chinese faces, Caucasian faces, and racially ambiguous morphed face stimuli. For the racially ambiguous faces, we led participants to believe that they were viewing either own-race Chinese faces or other-race Caucasian faces. Results showed that (1) Chinese participants scanned the nose of the true Chinese faces more than that of the true Caucasian faces, whereas they scanned the eyes of the Caucasian faces more than those of the Chinese faces; (2) they scanned the eyes, nose, and mouth equally for the ambiguous faces in the Chinese condition compared with those in the Caucasian condition; (3) when recognizing the true Chinese target faces, but not the true target Caucasian faces, the greater the fixation proportion on the nose, the faster the participants correctly recognized these faces. The same was true when racially ambiguous face stimuli were thought to be Chinese faces. These results provide the first evidence to show that (1) visual scanning patterns of faces are related to own-race face recognition response time, and (2) it is bottom-up facial physiognomic information of racial categories that mainly contributes to face scanning. However, top-down knowledge of racial categories can influence the relationship between face scanning patterns and recognition response time. PMID:25497461

  6. Geant4 simulation of clinical proton and carbon ion beams for the treatment of ocular melanomas with the full 3-D pencil beam scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Edoardo; Riccardi, Cristina; Rimoldi, Adele; Tamborini, Aurora [University of Pavia and the INFN section of Pavia, via Bassi 6, 27100 Pavia (Italy); Piersimoni, Pierluigi [Division of Radiation Research, Loma Linda University, Loma Linda, CA 92354 (United States); Ciocca, Mario [Medical Physics Unit, CNAO Foundation, Strada Campeggi 53, 27100 Pavia (Italy)

    2015-07-01

    This work investigates the possibility to use carbon ion beams delivered with active scanning modality, for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia. The radiotherapy with carbon ions offers many advantages with respect to the radiotherapy with protons or photons, such as a higher relative radio-biological effectiveness (RBE) and a dose release better localized to the tumor. The Monte Carlo (MC) Geant4 10.00 patch-03 toolkit is used to reproduce the complete CNAO extraction beam line, including all the active and passive components characterizing it. The simulation of proton and carbon ion beams and radiation scanned field is validated against CNAO experimental data. For the irradiation study of the ocular melanoma an eye-detector, representing a model of a human eye, is implemented in the simulation. Each element of the eye is reproduced with its chemical and physical properties. Inside the eye-detector a realistic tumor volume is placed and used as the irradiation target. A comparison between protons and carbon ions eye irradiations allows to study possible treatment benefits if carbon ions are used instead of protons. (authors)

  7. Adrenocortical Carcinoma: False Positive in an I-123 Metaiodobenzylguanidine Scan

    Energy Technology Data Exchange (ETDEWEB)

    Rey, Cristina Rodriguez; Candil, Aida Ortega; Galvan, Eliseo Vano; Martin, Maria Nieves Cabrera; Delgado, Jose Luis Carreras [Clinico San Carlos Hospital, Madrid (Spain)

    2016-06-15

    A 55-year-old man with a personal his history of left pheochromocytoma 2 years previously presented with an abdominal ultrasound showed a large left upper quadrant solid mass (calipers), with heterogeneous echogenicity and central cystic degeneration areas or necrosis. F-18 Fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT was performed as ACC was suspected. ACC is an uncommon malignant neoplasm of unknown cause; however, smoking and oral contraceptives may be risk factors. Patients usually present with advanced-stage disease and have poor prognosis, with a 2-year recurrence rate that ranges form 73 to 86 %. An MIBG scan was performed after injection of 185 MBq of I-123 MIBG intravenously. Single photon emission tomography (SPECT)/CT scan showed abnormal isotope accumulation in the tumor region. The patient underwent total resection of the tumor. The histology was of ACC, with areas of necrosis and cystic areas, so the result of the MIBG scan was a false positive. Authors divided false-positive MIBG studies into three categories. The first category is neuroendocrine lesions other than pheochromocytomas (tumors of the APUD series). the second category consists in adrenal lesions other than pheochromocytomas (adenomas, ACC) the reasons for this abnormal uptake are unclear. The third category consists of tracer uptake adjacent to the adrenal due to abnormalities in the route of excretion.

  8. Vibrating makes for better seeing: from the fly's micro eye movements to hyperacute visual sensors

    Directory of Open Access Journals (Sweden)

    Stéphane eViollet

    2014-04-01

    Full Text Available Active vision means that visual perception not only depends closely on the subject's own movements, but that these movements actually contribute to the visual perceptual processes. Vertebrates' and invertebrates' eye movements are probably part of an active visual process, but their exact role still remains to be determined. In this paper, studies on the retinal micro-movements occurring in the compound eye of the fly are reviewed. Several authors have located and identified the muscles involved in these small retinal movements. Others have established that these retinal micro-movements occur in walking and flying flies, but their exact functional role still remains to be determined. Many robotic studies have been performed in which animals' (flies' and spiders' miniature eye movements have been modelled, simulated and even implemented mechanically. Several robotic platforms have been endowed with artificial visual sensors performing periodic micro-scanning movements. Artificial eyes performing these active retinal micro-movements have some extremely interesting properties, such as hyperacuity and the ability to detect very slow movements (motion hyperacuity. The fundamental role of miniature eye movements still remains to be described in detail, but several studies on natural and artificial eyes have advanced considerably toward this goal.

  9. The role of eye protection in work-related eye injuries.

    Science.gov (United States)

    Fong, L P; Taouk, Y

    1995-05-01

    A recent survey of general hospitals by the Victorian Injury Surveillance System found that ocular trauma represented 15% of work-related injuries. As circumstances surrounding occupational eye injuries have been poorly documented previously, their associations to occupation, industry and work-safety practices, including safety eyewear use, need to be identified to develop appropriate preventive strategies for high-risk groups. From a prospective cross-sectional survey of all eye injuries treated at the Royal Victorian Eye and Ear Hospital, work-related cases were analysed for demographic, occupational and safety eye-wear information. Hospital-based data were supplemented by information from WorkCover Authorities and Labour Force statistics to derive incidence and cost estimates. There were 9390 eye injuries during the 18-month survey period; 42% (n=3923) of total and 29% (n=52) of penetrating ocular injuries occurred at work. The most frequently injured were metal, automotive and building trades workers grinding and drilling (41% of outpatients) and hammering (53% of penetrating eye injuries). Automotive workers had the highest frequency for penetrating injuries, and most were exposed to hammering and were also the least likely to wear safety eye-wear. Eye injuries are frequent (10% of work-related injuries) and highly preventable by the correct use of safety eye-wear, a cost-effective intervention that may result in cost savings of $59 million for work-type activities in the occupational and domestic settings in Australia each year.

  10. Poster - 40: Treatment Verification of a 3D-printed Eye Phantom for Proton Therapy

    International Nuclear Information System (INIS)

    Dunning, Chelsea; Lindsay, Clay; Unick, Nick; Sossi, Vesna; Martinez, Mark; Hoehr, Cornelia

    2016-01-01

    Purpose: Ocular melanoma is a form of eye cancer which is often treated using proton therapy. The benefit of the steep proton dose gradient can only be leveraged for accurate patient eye alignment. A treatment-planning program was written to plan on a 3D-printed anatomical eye-phantom, which was then irradiated to demonstrate the feasibility of verifying in vivo dosimetry for proton therapy using PET imaging. Methods: A 3D CAD eye model with critical organs was designed and voxelized into the Monte-Carlo transport code FLUKA. Proton dose and PET isotope production were simulated for a treatment plan of a test tumour, generated by a 2D treatment-planning program developed using NumPy and proton range tables. Next, a plastic eye-phantom was 3D-printed from the CAD model, irradiated at the TRIUMF Proton Therapy facility, and imaged using a PET scanner. Results: The treatment-planning program prediction of the range setting and modulator wheel was verified in FLUKA to treat the tumour with at least 90% dose coverage for both tissue and plastic. An axial isotope distribution of the PET isotopes was simulated in FLUKA and converted to PET scan counts. Meanwhile, the 3D-printed eye-phantom successfully yielded a PET signal. Conclusions: The 2D treatment-planning program can predict required parameters to sufficiently treat an eye tumour, which was experimentally verified using commercial 3D-printing hardware to manufacture eye-phantoms. Comparison between the simulated and measured PET isotope distribution could provide a more realistic test of eye alignment, and a variation of the method using radiographic film is being developed.

  11. Poster - 40: Treatment Verification of a 3D-printed Eye Phantom for Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, Chelsea; Lindsay, Clay; Unick, Nick; Sossi, Vesna; Martinez, Mark; Hoehr, Cornelia [University of British Columbia, University of Victoria, University of British Columbia, University of British Columbia, University of British Columbia, TRIUMF (Canada)

    2016-08-15

    Purpose: Ocular melanoma is a form of eye cancer which is often treated using proton therapy. The benefit of the steep proton dose gradient can only be leveraged for accurate patient eye alignment. A treatment-planning program was written to plan on a 3D-printed anatomical eye-phantom, which was then irradiated to demonstrate the feasibility of verifying in vivo dosimetry for proton therapy using PET imaging. Methods: A 3D CAD eye model with critical organs was designed and voxelized into the Monte-Carlo transport code FLUKA. Proton dose and PET isotope production were simulated for a treatment plan of a test tumour, generated by a 2D treatment-planning program developed using NumPy and proton range tables. Next, a plastic eye-phantom was 3D-printed from the CAD model, irradiated at the TRIUMF Proton Therapy facility, and imaged using a PET scanner. Results: The treatment-planning program prediction of the range setting and modulator wheel was verified in FLUKA to treat the tumour with at least 90% dose coverage for both tissue and plastic. An axial isotope distribution of the PET isotopes was simulated in FLUKA and converted to PET scan counts. Meanwhile, the 3D-printed eye-phantom successfully yielded a PET signal. Conclusions: The 2D treatment-planning program can predict required parameters to sufficiently treat an eye tumour, which was experimentally verified using commercial 3D-printing hardware to manufacture eye-phantoms. Comparison between the simulated and measured PET isotope distribution could provide a more realistic test of eye alignment, and a variation of the method using radiographic film is being developed.

  12. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  13. Developing an eye-tracking algorithm as a potential tool for early diagnosis of autism spectrum disorder in children.

    Directory of Open Access Journals (Sweden)

    Natalia I Vargas-Cuentas

    Full Text Available Autism spectrum disorder (ASD currently affects nearly 1 in 160 children worldwide. In over two-thirds of evaluations, no validated diagnostics are used and gold standard diagnostic tools are used in less than 5% of evaluations. Currently, the diagnosis of ASD requires lengthy and expensive tests, in addition to clinical confirmation. Therefore, fast, cheap, portable, and easy-to-administer screening instruments for ASD are required. Several studies have shown that children with ASD have a lower preference for social scenes compared with children without ASD. Based on this, eye-tracking and measurement of gaze preference for social scenes has been used as a screening tool for ASD. Currently available eye-tracking software requires intensive calibration, training, or holding of the head to prevent interference with gaze recognition limiting its use in children with ASD.In this study, we designed a simple eye-tracking algorithm that does not require calibration or head holding, as a platform for future validation of a cost-effective ASD potential screening instrument. This system operates on a portable and inexpensive tablet to measure gaze preference of children for social compared to abstract scenes. A child watches a one-minute stimulus video composed of a social scene projected on the left side and an abstract scene projected on the right side of the tablet's screen. We designed five stimulus videos by changing the social/abstract scenes. Every child observed all the five videos in random order. We developed an eye-tracking algorithm that calculates the child's gaze preference for the social and abstract scenes, estimated as the percentage of the accumulated time that the child observes the left or right side of the screen, respectively. Twenty-three children without a prior history of ASD and 8 children with a clinical diagnosis of ASD were evaluated. The recorded video of the child´s eye movement was analyzed both manually by an observer

  14. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  15. Isolated left-sided pulmonary artery agenesis with left lung hypoplasia: A report of two cases

    Directory of Open Access Journals (Sweden)

    V Govindaraj

    2017-01-01

    Full Text Available Unilateral absence of pulmonary artery or pulmonary artery agenesis (UAPA is a rare congenital malformation that can present as an isolated lesion or in association with other cardiac anomalies. Though congenital, presentation in adults are also reported. Most common presentation in adults is of exercise intolerance. The developing lung on the affected side is hypoplastic. Diagnosis of UAPA is established by imaging methods like CT and MRI . There is no specific treatment for this condition. Treatment depends on patients symptomatology, presence of pulmonary hypertension and collateral circulation. Presence of pulmonary hypertension carries a bad prognosis. We present two adult patients with isolated left sided unilateral pulmonary artery agenesis with ipsilateral lung hypoplasia. The diagnosis was confirmed by CT chest and perfusion scan.

  16. Retinal Thickening and Photoreceptor Loss in HIV Eyes without Retinitis.

    Directory of Open Access Journals (Sweden)

    Cheryl A Arcinue

    Full Text Available To determine the presence of structural changes in HIV retinae (i.e., photoreceptor density and retinal thickness in the macula compared with age-matched HIV-negative controls.Cohort of patients with known HIV under CART (combination Antiretroviral Therapy treatment were examined with a flood-illuminated retinal AO camera to assess the cone photoreceptor mosaic and spectral-domain optical coherence tomography (SD-OCT to assess retinal layers and retinal thickness.Twenty-four eyes of 12 patients (n = 6 HIV-positive and 6 HIV-negative were imaged with the adaptive optics camera. In each of the regions of interest studied (nasal, temporal, superior, inferior, the HIV group had significantly less mean cone photoreceptor density compared with age-matched controls (difference range, 4,308-6,872 cones/mm2. A different subset of forty eyes of 20 patients (n = 10 HIV-positive and 10 HIV-negative was included in the retinal thickness measurements and retinal layer segmentation with the SD-OCT. We observed significant thickening in HIV positive eyes in the total retinal thickness at the foveal center, and in each of the three horizontal B-scans (through the macular center, superior, and inferior to the fovea. We also noted that the inner retina (combined thickness from ILM through RNFL to GCL layer was also significantly thickened in all the different locations scanned compared with HIV-negative controls.Our present study shows that the cone photoreceptor density is significantly reduced in HIV retinae compared with age-matched controls. HIV retinae also have increased macular retinal thickness that may be caused by inner retinal edema secondary to retinovascular disease in HIV. The interaction of photoreceptors with the aging RPE, as well as possible low-grade ocular inflammation causing diffuse inner retinal edema, may be the key to the progressive vision changes in HIV-positive patients without overt retinitis.

  17. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? Written By: Kierstan ...

  18. Amelioration of ultraviolet-induced photokeratitis in mice treated with astaxanthin eye drops.

    Science.gov (United States)

    Lennikov, Anton; Kitaichi, Nobuyoshi; Fukase, Risa; Murata, Miyuki; Noda, Kousuke; Ando, Ryo; Ohguchi, Takeshi; Kawakita, Tetsuya; Ohno, Shigeaki; Ishida, Susumu

    2012-01-01

    Ultraviolet (UV) acts as low-dose ionizing radiation. Acute UVB exposure causes photokeratitis and induces apoptosis in corneal cells. Astaxanthin (AST) is a carotenoid, present in seafood, that has potential clinical applications due to its high antioxidant activity. In the present study, we examined whether topical administration of AST has preventive and therapeutic effects on UV-photokeratitis in mice. C57BL/6 mice were administered with AST diluted in polyethylene glycol (PEG) in instillation form (15 μl) to the right eye. Left eyes were given vehicle alone as controls. Immediately after the instillation, the mice, under anesthesia, were irradiated with UVB at a dose of 400 mJ/cm². Eyeballs were collected 24 h after irradiation and stained with H&E and TUNEL. In an in vitro study, mouse corneal epithelial (TKE2) cells were cultured with AST before UV exposure to quantify the UV-derived cytotoxicity. UVB exposure induced cell death and thinning of the corneal epithelium. However, the epithelium was morphologically well preserved after irradiation in AST-treated corneas. Irradiated corneal epithelium was significantly thicker in eyes treated with AST eye drops, compared to those treated with vehicles (peyes than controls after irradiation (peffect increased with the dose of AST. Topical AST administration may be a candidate treatment to limit the damages by UV irradiation with wide clinical applications.

  19. A functional probe with bowtie aperture and bull's eye structure for nanolithograph

    International Nuclear Information System (INIS)

    Wang Shuo; Wang Qiao; Guo Ying-Yan; Pan Shi; Li Xu-Feng

    2012-01-01

    The bowtie aperture surrounded by concentric gratings (the bull's eye structure) integrated on the near-field scanning optical microscopy (NSOM) probe (aluminum coated fiber tip) for nanolithography has been investigated using the finite-difference time domain (FDTD) method. By modifying the parameters of the bowtie aperture and the concentric gratings, a maximal field enhancement factor of 391.69 has been achieved, which is 18 times larger than that obtained from the single bowtie aperture. Additionally, the light spot depends on the gap size of the bowtie aperture and can be confined to sub-wavelength. The superiority of the combination of the bowtie aperture and the bull's eye structure is confirmed, and the mechanism for the electric field enhancement in this derived structure is analyzed

  20. A functional probe with bowtie aperture and bull's eye structure for nanolithograph

    Science.gov (United States)

    Wang, Shuo; Li, Xu-Feng; Wang, Qiao; Guo, Ying-Yan; Pan, Shi

    2012-10-01

    The bowtie aperture surrounded by concentric gratings (the bull's eye structure) integrated on the near-field scanning optical microscopy (NSOM) probe (aluminum coated fiber tip) for nanolithography has been investigated using the finite-difference time domain (FDTD) method. By modifying the parameters of the bowtie aperture and the concentric gratings, a maximal field enhancement factor of 391.69 has been achieved, which is 18 times larger than that obtained from the single bowtie aperture. Additionally, the light spot depends on the gap size of the bowtie aperture and can be confined to sub-wavelength. The superiority of the combination of the bowtie aperture and the bull's eye structure is confirmed, and the mechanism for the electric field enhancement in this derived structure is analyzed.

  1. Dry eyes : a commonly missed eye condition

    OpenAIRE

    Vella, Mario;

    2014-01-01

    Tears are an important component in providing moisture and lubrication for the eyes, thereby maintaining vision and comfort. Dry eyes (keratoconjunctivitis sicca) result when there is either decreased production of tears or by poor tear quality which in turn lead to more rapid evaporation.

  2. Twenty years' delay of fellow eye involvement in herpes simplex virus type 2-associated bilateral acute retinal necrosis syndrome

    NARCIS (Netherlands)

    Schlingemann, R. O.; Bruinenberg, M.; Wertheim-van Dillen, P.; Feron, E.

    1996-01-01

    PURPOSE: To describe a case of acute retinal necrosis with concurrent encephalitis and determine the causative virus. The patient had a history of presumed acute retinal necrosis in the left eye at the age of 8 years and recurrent genital herpes. METHODS: Diagnostic anterior chamber puncture of the

  3. Aggressive Ewing's sarcoma appearing as a cold lesion on bone scan

    International Nuclear Information System (INIS)

    Chatti, K.; Guezguez, M.; Maha Ben Fredj, M.; Sfar, R.; Essabbah, H.; Mtaoumi, M.; Chatti, K.

    2009-01-01

    Ewing's sarcoma classically presents as a hot spot on bone scan as a result of increased vascularity of the tumor and new bone formation. Purpose We report and analyze an uncommon pattern of a 'cold' lesion in Ewing's sarcoma on bone scan and its pathophysiologic significance. Case report A 15-year-old boy complaining of thigh pain. CT scan evoked Ewing's sarcoma or osteitis. MRI evoked chronic osteitis. Scintigraphy showed a fairly intense and heterogeneous uptake on the femoral lesion and no abnormal uptake elsewhere. Biopsy showed none pathologic pattern. Three months later, a second biopsy concluded to Ewing's sarcoma. Bone scan showed a larger lesion with peripheral intense uptake centered by enlarged 'cold' area in the left femoral diaphysis and no evident bone metastasis. The patient underwent chemotherapy and surgery. Three months later, bone scan showed extensive skeletal metastasis. Conclusion Ewing's sarcoma appears usually as an intense lesion on bone scan. Nevertheless, decreased radiopharmaceutical uptake or 'cold' lesion may be seen in aggressive Ewing's sarcoma with lytic tumor, growth of which is very rapid and bony reaction is minimal. (authors)

  4. Infrared scanning laser ophthalmoscope imaging of the macula and its correlation with functional loss and structural changes in patients with stargardt disease.

    Science.gov (United States)

    Anastasakis, Anastasios; Fishman, Gerald A; Lindeman, Martin; Genead, Mohamed A; Zhou, Wensheng

    2011-05-01

    To correlate the degree of functional loss with structural changes in patients with Stargardt disease. Eighteen eyes of 10 patients with Stargardt disease were studied. Scanning laser ophthalmoscope infrared images were compared with corresponding spectral-domain optical coherence tomography scans. Additionally, scanning laser ophthalmoscope microperimetry was performed, and results were superimposed on scanning laser ophthalmoscope infrared images and in selected cases on fundus autofluorescence images. Seventeen of 18 eyes showed a distinct hyporeflective foveal and/or perifoveal area with distinct borders on scanning laser ophthalmoscope infrared images, which was less evident on funduscopy and incompletely depicted in fundus autofluorescence images. This hyporeflective zone corresponded to areas of significantly elevated psychophysical thresholds on microperimetry testing, in addition to thinning of the retinal pigment epithelium and disorganization or loss of the photoreceptor cell inner segment-outer segment junction and external-limiting membrane on spectral-domain optical coherence tomography. Scanning laser ophthalmoscope infrared fundus images are useful for depicting retinal structural changes in patients with Stargardt disease. A spectral-domain optical coherence tomography/scanning laser ophthalmoscope microperimetry device allows for a direct correlation of structural abnormalities with functional defects that will likely be applicable for the determination of retinal areas for potential improvement of retinal function in these patients during future clinical trials and for the monitoring of the diseases' natural history.

  5. Eye Tracker Accuracy: Quantitative Evaluation of the Invisible Eye Center Location

    OpenAIRE

    Wyder, Stephan; Cattin, Philippe C.

    2017-01-01

    Purpose. We present a new method to evaluate the accuracy of an eye tracker based eye localization system. Measuring the accuracy of an eye tracker's primary intention, the estimated point of gaze, is usually done with volunteers and a set of fixation points used as ground truth. However, verifying the accuracy of the location estimate of a volunteer's eye center in 3D space is not easily possible. This is because the eye center is an intangible point hidden by the iris. Methods. We evaluate ...

  6. Efficacy of topical cyclosporine 0.05% eye drops in the treatment of dry eyes

    OpenAIRE

    Haitham Y Al-Nashar

    2015-01-01

    Purpose The aim of the present study was to evaluate the effectiveness of cyclosporine 0.05% in the treatment of dry-eye disease. Patients and methods A total of 35 eyes of 20 patients with dry-eye disease were included in the present study. Ten patients (20 eyes) had dry eyes associated with systemic rheumatologic disease (Sjögren′s syndrome), five patients (10 eyes) had dry eyes after undergoing laser in-situ keratomileusis, and five patients (five eyes) had dry eyes after cataract...

  7. Premotor neurons encode torsional eye velocity during smooth-pursuit eye movements

    Science.gov (United States)

    Angelaki, Dora E.; Dickman, J. David

    2003-01-01

    Responses to horizontal and vertical ocular pursuit and head and body rotation in multiple planes were recorded in eye movement-sensitive neurons in the rostral vestibular nuclei (VN) of two rhesus monkeys. When tested during pursuit through primary eye position, the majority of the cells preferred either horizontal or vertical target motion. During pursuit of targets that moved horizontally at different vertical eccentricities or vertically at different horizontal eccentricities, eye angular velocity has been shown to include a torsional component the amplitude of which is proportional to half the gaze angle ("half-angle rule" of Listing's law). Approximately half of the neurons, the majority of which were characterized as "vertical" during pursuit through primary position, exhibited significant changes in their response gain and/or phase as a function of gaze eccentricity during pursuit, as if they were also sensitive to torsional eye velocity. Multiple linear regression analysis revealed a significant contribution of torsional eye movement sensitivity to the responsiveness of the cells. These findings suggest that many VN neurons encode three-dimensional angular velocity, rather than the two-dimensional derivative of eye position, during smooth-pursuit eye movements. Although no clear clustering of pursuit preferred-direction vectors along the semicircular canal axes was observed, the sensitivity of VN neurons to torsional eye movements might reflect a preservation of similar premotor coding of visual and vestibular-driven slow eye movements for both lateral-eyed and foveate species.

  8. Verification of eye lens dose in IMRT by MOSFET measurement.

    Science.gov (United States)

    Wang, Xuetao; Li, Guangjun; Zhao, Jianling; Song, Ying; Xiao, Jianghong; Bai, Sen

    2018-04-17

    The eye lens is recognized as one of the most radiosensitive structures in the human body. The widespread use of intensity-modulated radiotherapy (IMRT) complicates dose verification and necessitates high standards of dose computation. The purpose of this work was to assess the computed dose accuracy of eye lens through measurements using a metal-oxide-semiconductor field-effect transistor (MOSFET) dosimetry system. Sixteen clinical IMRT plans of head and neck patients were copied to an anthropomorphic head phantom. Measurements were performed using the MOSFET dosimetry system based on the head phantom. Two MOSFET detectors were imbedded in the eyes of the head phantom as the left and the right lens, covered by approximately 5-mm-thick paraffin wax. The measurement results were compared with the calculated values with a dose grid size of 1 mm. Sixteen IMRT plans were delivered, and 32 measured lens doses were obtained for analysis. The MOSFET dosimetry system can be used to verify the lens dose, and our measurements showed that the treatment planning system used in our clinic can provide adequate dose assessment in eye lenses. The average discrepancy between measurement and calculation was 6.7 ± 3.4%, and the largest discrepancy was 14.3%, which met the acceptability criterion set by the American Association of Physicists in Medicine Task Group 53 for external beam calculation for multileaf collimator-shaped fields in buildup regions. Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  9. Anatomical variations of the thymus in relation to the left brachiocephalic vein, findings of necropsia.

    Science.gov (United States)

    Plaza, Oscar Alonso; Moreno, Freddy

    2018-04-01

    Two cases of anatomical variations of the thymus are presented with respect to the anatomical relations with the left brachiocephalic vein and found during the necropsy process. Less than 2 days after birth with Noonan Syndrome, when the left brachiocephalic vein was scanning behind the upper thymus horns, there were other adjacent lesions consisting of three supernumerary spleens and three hepatic veins. The second case was an 8-year-old infant with child malpractice who died from urinary sepsis due to obstructive uropathy, in which case the upper lobes of the thymus were fused and formed a ring through which the left brachiocephalic vein passed. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Burning Eye Syndrome: Do Neuropathic Pain Mechanisms Underlie Chronic Dry Eye?

    Science.gov (United States)

    Kalangara, Jerry P; Galor, Anat; Levitt, Roy C; Felix, Elizabeth R; Alegret, Ramon; Sarantopoulos, Constantine D

    2016-04-01

    Dry eye is a multi-factorial disorder that manifests with painful ocular symptoms and visual disturbances, which can only be partly attributed to tear dysfunction. This disorder may also involve neuroplasticity in response to neuronal injury. This review will emphasize the key characteristics of dry eye pain and its pathologic mechanisms, making the argument that a subset of dry eye represents a neuropathic pain disorder of the eye, more appropriately called "burning eye syndrome." A literature review was conducted using a PubMed search focusing on dry eye, corneal nociception, and neuropathic pain. Articles were reviewed and those discussing clinical course, pathophysiology, and neuronal regulation of chronic ocular pain as related to dry eye were summarized. We found that there is a discordance between ocular pain and dryness on the ocular surface. Although tear dysfunction may be one of the initial insults, its persistence may be associated with repeated ocular sensory nerve injury leading to an acute-to-chronic pain transition associated with neuropathologic changes (peripheral and central sensitization), neuronal dysfunction, and spontaneous ocular pain. Dry eye is becoming a major health concern due to its increasing incidence, significant morbidity, and economic burden. Recent evidence suggests that a subset of dry eye may be better represented as a chronic neuropathic pain disorder due to its features of dysesthesia, spontaneous pain, allodynia, and hyperalgesia. Future therapies targeted at the underlying neuroplasticity may yield improved efficacy for patients with this subset of dry eye, which we term "burning eye syndrome." © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Fluorescein eye stain

    Science.gov (United States)

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  12. Wavefront sensorless adaptive optics ophthalmoscopy in the human eye

    Science.gov (United States)

    Hofer, Heidi; Sredar, Nripun; Queener, Hope; Li, Chaohong; Porter, Jason

    2011-01-01

    Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor ‘beacon’ can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains. PMID:21934779

  13. Visual scan-path analysis with feature space transient fixation moments

    Science.gov (United States)

    Dempere-Marco, Laura; Hu, Xiao-Peng; Yang, Guang-Zhong

    2003-05-01

    The study of eye movements provides useful insight into the cognitive processes underlying visual search tasks. The analysis of the dynamics of eye movements has often been approached from a purely spatial perspective. In many cases, however, it may not be possible to define meaningful or consistent dynamics without considering the features underlying the scan paths. In this paper, the definition of the feature space has been attempted through the concept of visual similarity and non-linear low dimensional embedding, which defines a mapping from the image space into a low dimensional feature manifold that preserves the intrinsic similarity of image patterns. This has enabled the definition of perceptually meaningful features without the use of domain specific knowledge. Based on this, this paper introduces a new concept called Feature Space Transient Fixation Moments (TFM). The approach presented tackles the problem of feature space representation of visual search through the use of TFM. We demonstrate the practical values of this concept for characterizing the dynamics of eye movements in goal directed visual search tasks. We also illustrate how this model can be used to elucidate the fundamental steps involved in skilled search tasks through the evolution of transient fixation moments.

  14. Left Ventricular Hypertrophy in Pediatric Hypertension: A Mini Review

    Directory of Open Access Journals (Sweden)

    Robert P. Woroniecki

    2017-05-01

    Full Text Available Adults with arterial hypertension (HTN have stroke, myocardial infarction, end-stage renal disease (ESRD, or die at higher rates than those without. In children, HTN leads to target organ damage, which includes kidney, brain, eye, blood vessels, and heart, which precedes “hard outcomes” observed in adults. Left ventricular hypertrophy (LVH or an anatomic and pathologic increase in left ventricular mass (LVM in response to the HTN is a pediatric surrogate marker for HTN-induced morbidity and mortality in adults. This mini review discusses current definitions, clinically relevant methods of LVM measurements and normalization methods, its epidemiology, management, and issue of reversibility in children with HTN. Pediatric definition of LVH and abnormal LVM is not uniformed. With multiple definitions, prevalence of pediatric HTN-induced LVH is difficult to ascertain. In addition while in adults cardiac magnetic resonance imaging is considered “the gold standard” for LVM and LVH determination, pediatric data are limited to “special populations”: ESRD, transplant, and obese children. We summarize available data on pediatric LVH treatment and reversibility and offer future directions in addressing LVH in children with HTN.

  15. High-resolution imaging of retinal nerve fiber bundles in glaucoma using adaptive optics scanning laser ophthalmoscopy.

    Science.gov (United States)

    Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Ueda-Arakawa, Naoko; Yoshida, Sachiko; Akagi, Tadamichi; Ikeda, Hanako Ohashi; Nonaka, Atsushi; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa

    2013-05-01

    To detect pathologic changes in retinal nerve fiber bundles in glaucomatous eyes seen on images obtained by adaptive optics (AO) scanning laser ophthalmoscopy (AO SLO). Prospective cross-sectional study. Twenty-eight eyes of 28 patients with open-angle glaucoma and 21 normal eyes of 21 volunteer subjects underwent a full ophthalmologic examination, visual field testing using a Humphrey Field Analyzer, fundus photography, red-free SLO imaging, spectral-domain optical coherence tomography, and imaging with an original prototype AO SLO system. The AO SLO images showed many hyperreflective bundles suggesting nerve fiber bundles. In glaucomatous eyes, the nerve fiber bundles were narrower than in normal eyes, and the nerve fiber layer thickness was correlated with the nerve fiber bundle widths on AO SLO (P fiber layer defect area on fundus photography, the nerve fiber bundles on AO SLO were narrower compared with those in normal eyes (P optic disc, the nerve fiber bundle width was significantly lower, even in areas without nerve fiber layer defect, in eyes with glaucomatous eyes compared with normal eyes (P = .026). The mean deviations of each cluster in visual field testing were correlated with the corresponding nerve fiber bundle widths (P = .017). AO SLO images showed reduced nerve fiber bundle widths both in clinically normal and abnormal areas of glaucomatous eyes, and these abnormalities were associated with visual field defects, suggesting that AO SLO may be useful for detecting early nerve fiber bundle abnormalities associated with loss of visual function. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. CT scan findings in three cases of multiple sclerosis with homonymous hemianopsia

    International Nuclear Information System (INIS)

    Arikado, Takuji; Ariga, Hiroko; Kase, Manabu; Nagata, Renpei; Tashiro, Kunio

    1983-01-01

    Three cases of clinically definite multiple sclerosis manifested homonymous hemianopsia. A 35-year-old female, in whom right optic neuritis developed as the initial symptom, manifested right homonymous hemianopsia 4 months later followed by cerebral symptoms another 4 months later. A 25-year-old male developed sudden brain stem and cerebellar symptoms associated with right abducens palsy and right homonymous hemianopsia. In a 26-year-old female developed right homonymous hemianopsia 13 years after the first attack of recurrent optic neuritis. CT-scan in these three cases revealed the presence of a ''plaque'' located in the white matter of the left occipital lobe in cases 1 and 2 and in the left peririgone white matter in case 3 as the causative lesion for the right homonymous hemianopsia. These findings indicate that the optic radiation may be involved in multiple sclerosis resulting in homonymous hemianopsia. CT scan is of value in determining the location of the affected intracranial lesion in multiple sclerosis. (author)

  17. Prediction of acute cardiac rejection by changes in left ventricular volumes

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.K.; Boniaszczuk, J.

    1988-01-01

    Sixteen patients underwent heart transplantation (11 orthotopic, five heterotopic). Monitoring for acute rejection was by both endomyocardial biopsy (EMB) and multigated equilibrium blood pool scanning with technetium 99m-labelled red blood cells. From the scans information was obtained on left ventricular volumes (stroke, end-diastolic, and end-systolic), ejection fraction, and heart rate. Studies (208) were made in the 16 patients. There was a highly significant correlation between the reduction in stroke volume and end-diastolic volume (and a less significant correlation in end-systolic volume) and increasing acute rejection seen on EMB. Heart rate and ejection fraction did not correlate with the development of acute rejection. Correlation of a combination of changes in stroke volume and end-diastolic volume with EMB showed a sensitivity of 85% and a specificity of 96%. Radionuclide scanning is therefore a useful noninvasive tool for monitoring acute rejection

  18. Eye-Tracking as a Tool to Evaluate Functional Ability in Everyday Tasks in Glaucoma

    Directory of Open Access Journals (Sweden)

    Enkelejda Kasneci

    2017-01-01

    Full Text Available To date, few studies have investigated the eye movement patterns of individuals with glaucoma while they undertake everyday tasks in real-world settings. While some of these studies have reported possible compensatory gaze patterns in those with glaucoma who demonstrated good task performance despite their visual field loss, little is known about the complex interaction between field loss and visual scanning strategies and the impact on task performance and, consequently, on quality of life. We review existing approaches that have quantified the effect of glaucomatous visual field defects on the ability to undertake everyday activities through the use of eye movement analysis. Furthermore, we discuss current developments in eye-tracking technology and the potential for combining eye-tracking with virtual reality and advanced analytical approaches. Recent technological developments suggest that systems based on eye-tracking have the potential to assist individuals with glaucomatous loss to maintain or even improve their performance on everyday tasks and hence enhance their long-term quality of life. We discuss novel approaches for studying the visual search behavior of individuals with glaucoma that have the potential to assist individuals with glaucoma, through the use of personalized programs that take into consideration the individual characteristics of their remaining visual field and visual search behavior.

  19. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  20. A comparison of preservative-free diclofenac and preserved diclofenac eye drops after cataract surgery in patients with diabetic retinopathy.

    Science.gov (United States)

    Yasuda, Kanako; Miyazawa, Akiko; Shimura, Masahiko

    2012-06-01

    The aim of this study was to compare the anti-inflammatory efficacy of preservative-free and preserved 0.1% diclofenac eye drops for the management of postoperative inflammation after cataract surgery in patients with nonproliferative diabetic retinopathy and in normal controls. Forty-two diabetic patients and 50 normal control patients who underwent small-incision phacoemulsification cataract surgery bilaterally received topical preservative-free diclofenac in 1 eye and preserved diclofenac in the other eye. The corrected distance visual acuity (CDVA) as determined by a logarithm of the minimum angle of resolution (logMAR) chart, intraocular pressure (IOP), foveal thickness (FT) using optical coherence tomography (OCT), and the anterior chamber flare (ACF) score measured with a laser flare cell meter were monitored for 12 weeks after surgery. In the eyes with diabetic retinopathy, there were no significant differences in CDVA, IOP, FT, and ACF score between the right and left eyes at the initial exam. After cataract surgery, changes in CDVA, IOP, and FT were not influenced by the preservative in the diclofenac eye drops. In contrast, the ACF score in the eyes treated with preserved diclofenac showed slower recovery from postoperative inflammation than the eyes treated with preservative-free diclofenac. In the normal control eyes, similar but milder changes were observed in each of the clinical parameters. Because preservative suppressed the anti-inflammatory efficacy of topical diclofenac after cataract surgery, preservative-free diclofenac may have an improved safety profile during postoperative treatment, especially in patients with diabetic retinopathy.

  1. Eye-Tracking Study on Facial Emotion Recognition Tasks in Individuals with High-Functioning Autism Spectrum Disorders

    Science.gov (United States)

    Tsang, Vicky

    2018-01-01

    The eye-tracking experiment was carried out to assess fixation duration and scan paths that individuals with and without high-functioning autism spectrum disorders employed when identifying simple and complex emotions. Participants viewed human photos of facial expressions and decided on the identification of emotion, the negative-positive emotion…

  2. Using an eye tracker for accurate eye movement artifact correction

    NARCIS (Netherlands)

    Kierkels, J.J.M.; Riani, J.; Bergmans, J.W.M.; Boxtel, van G.J.M.

    2007-01-01

    We present a new method to correct eye movement artifacts in electroencephalogram (EEG) data. By using an eye tracker, whose data cannot be corrupted by any electrophysiological signals, an accurate method for correction is developed. The eye-tracker data is used in a Kalman filter to estimate which

  3. Memory of music: roles of right hippocampus and left inferior frontal gyrus.

    Science.gov (United States)

    Watanabe, Takamitsu; Yagishita, Sho; Kikyo, Hideyuki

    2008-01-01

    We investigated neural correlates of retrieval success for music memory using event-related functional magnetic resonance imaging. To minimize the interference from MRI scan noise, we used sparse temporal sampling technique. Newly composed music materials were employed as stimuli, which enabled us to detect regions in absence of effects of experience with the music stimuli in this study. Whole brain analyses demonstrated significant retrieval success activities in the right hippocampus, bilateral lateral temporal regions, left inferior frontal gyrus and left precuneus. Anatomically defined region-of-interests analyses showed that the activity of the right hippocampus was stronger than that of the left, while the activities of the inferior frontal gyri showed the reverse pattern. Furthermore, performance-based analyses demonstrated that the retrieval success activity of the right hippocampus was positively correlated with the corrected recognition rate, suggesting that the right hippocampus contributes to the accuracy of music retrieval outcome.

  4. Comparison of Scheimpflug imaging parameters between steep and keratoconic corneas of Caucasian eyes

    Directory of Open Access Journals (Sweden)

    Huseynova T

    2016-04-01

    Full Text Available Tukezban Huseynova,1 Farah Abdulaliyeva,2 Michele Lanza3 1Briz-L Eye Clinic, 2National Ophthalmology Center, Baku, Azerbaijan; 3Second University of Naples, Caserta, Campania, Italy Purpose: To compare the keratometric and pachymetric parameters of healthy eyes with those affected by steep cornea and keratoconus (KC using Scheimpflug camera.Setting: Briz-L Eye Clinic, Baku, Azerbaijan.Design: A cross-sectional study.Methods: In this study, 49 KC (Amsler–Krumeich stage 1 eyes and 36 healthy eyes were enrolled. A complete ophthalmic evaluation and a Scheimpflug camera scan were performed in every eye included in the study. Tomographic parameters such as parameters from the front and back cornea, maximum keratometry reading (Kmax, corneal volume (CV, anterior chamber volume (ChV, anterior chamber depth (ACD, anterior chamber angle (AC angle, keratometric power deviation (KPD, maximum front elevation (Max FE, and maximum back elevation (Max BE, as well as pachymetric progression indices (PPI, Ambrosio relational thickness (ART, index of surface variance (ISV, index of vertical asymmetry (IVA, center keratoconus index (CKI, index of height asymmetry (IHA, index of height decentration (IHD, and radius minimum (RM were collected and statistically compared between the two groups.Results: PPI, ART, ISV, IVA, CKI, IHA, IHD, and RM parameter values were significantly different (P<0.05 between the KC and healthy eyes. There were no significant differences in K mean and Q values of the frontal corneal parameters, as well as in Kmax, AC angle, RM, back, and front astigmatism, between stage 1 keratoconic and normal Caucasian eyes with steep cornea. All other parameters such as K mean and Q values of the back corneal parameters, Max FE, Max BE, ACD, ChV, and CV showed significant differences between the groups (P<0.05 for all. Conclusion: Scheimpflug imaging is able to detect corneal morphological differences between stage 1 KC eyes and healthy eyes with

  5. About the Eye

    Medline Plus

    Full Text Available ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  6. About the Eye

    Medline Plus

    Full Text Available ... your eye. It helps your eye focus light so things look sharp and clear. Sclera (SKLEH-ruh) ... the different parts of your eye work together so you can see and make sense of the ...

  7. Eye absence does not regulate planarian stem cells during eye regeneration

    OpenAIRE

    LoCascio, Samuel A.; Lapan, Sylvain W.; Reddien, Peter W.

    2017-01-01

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, ...

  8. Early intraocular pressure change after peripheral iridotomy with ultralow fluence pattern scanning laser and Nd:YAG laser in primary angle-closure suspect: Kowloon East Pattern Scanning Laser Study Report No. 3.

    Science.gov (United States)

    Chan, Jeffrey Chi Wang; Choy, Bonnie Nga Kwan; Chan, Orlando Chia Chieh; Li, Kenneth Kai Wang

    2018-02-01

    Our purpose was to assess the early intraocular pressure (IOP) changes of ultralow fluence laser iridotomy using pattern scanning laser followed by neodymium:yttrium-aluminum-gamet (Nd:YAG) laser. This is a prospective interventional study. Thirty-three eyes of 33 adult Chinese primary angle-closure suspect subjects were recruited for prophylactic laser peripheral iridotomy. Sequential laser peripheral iridotomy was performed using pattern scanning laser followed by Nd:YAG laser. Visual acuity (VA) and IOP were measured before treatment, at 1 h, 1 day, 1 week, 1 month, 3 months and 6 months after laser. Laser energy used and complications were documented. Corneal endothelial cell count was examined at baseline and 6 months. Patency of the iridotomy was assessed at each follow-up visit. All subjects achieved patent iridotomy in a single session. The mean energy used was 0.335+/-0.088 J for the pattern scanning laser, and 4.767+/-5.780 mJ for the Nd:YAG laser. The total mean energy was 0.339+/-0.089 J. None of the eyes developed a clinically significant IOP spike (≥ 8 mmHg) at 1 h and 1 day after laser use. Only four eyes developed higher IOP at 1 h and all were ≤3 mmHg compared to baseline. The mean IOP was 13.8+/-2.5 mmHg at 1 h and 11.5+/-2.2 mmHg at 1 day, both were significantly lower than baseline (15.8+/-2.1 mmHg) (P laser compared to baseline (0.23 vs 0.26). There was also no statistically significant difference in mean VA at other follow-up visits compared to baseline. Peripheral iridotomy closure was encountered in two (6.1%) eyes, one at 1 month and another at 6 months follow-up. There were no complications including hyphema, peripheral anterior synechia formation nor prolonged inflammation throughout the follow-up period. There was no significant loss in corneal endothelial cell counts at 6 months (2255+/-490) compared to baseline (2303+/-386) (P = 0.347). Sequential LPI using an ultralow fluence pattern scanning laser

  9. Patterning of a compound eye on an extinct dipteran wing.

    Science.gov (United States)

    Dinwiddie, April; Rachootin, Stan

    2011-04-23

    We have discovered unexpected similarities between a novel and characteristic wing organ in an extinct biting midge from Baltic amber, Eohelea petrunkevitchi, and the surface of a dipteran's compound eye. Scanning electron microscope images now reveal vestigial mechanoreceptors between the facets of the organ. We interpret Eohelea's wing organ as the blending of these two developmental systems: the formation and patterning of the cuticle in the eye and of the wing. Typically, only females in the genus carry this distinctive, highly organized structure. Two species were studied (E. petrunkevitchi and E. sinuosa), and the structure differs in form between them. We examine Eohelea's wing structures for modes of fabrication, material properties and biological functions, and the effective ecological environment in which these midges lived. We argue that the current view of the wing organ's function in stridulation has been misconstrued since it was described half a century ago.

  10. Diagnostic capability of scanning laser polarimetry with and without enhanced corneal compensation and optical coherence tomography.

    Science.gov (United States)

    Benítez-del-Castillo, Javier; Martinez, Antonio; Regi, Teresa

    2011-01-01

    To compare the abilities of the current commercially available versions of scanning laser polarimetry (SLP) and optical coherence tomography (OCT), SLP-variable corneal compensation (VCC), SLP-enhanced corneal compensation (ECC), and high-definition (HD) OCT, in discriminating between healthy eyes and those with early-to-moderate glaucomatous visual field loss. Healthy volunteers and patients with glaucoma who met the eligibility criteria were consecutively enrolled in this prospective, cross-sectional, observational study. Subjects underwent complete eye examination, automated perimetry, SLP-ECC, SLP-VCC, and HD-OCT. Scanning laser polarimetry parameters were recalculated in 90-degree segments (quadrants) in the calculation circle to be compared. Areas under the receiver operating characteristic curve (AUROCs) were calculated for every parameter in order to compare the ability of each imaging modality to differentiate between normal and glaucomatous eyes. Fifty-five normal volunteers (mean age 59.1 years) and 33 patients with glaucoma (mean age 63.8 years) were enrolled. Average visual field mean deviation was -6.69 dB (95% confidence interval -8.07 to -5.31) in the glaucoma group. The largest AUROCs were associated with nerve fiber indicator (0.880 and 0.888) for the SLP-VCC and SLP-ECC, respectively, and with the average thickness in the HD-OCT (0.897). The best performing indices for the SLP-VCC, SLP-ECC, and HD OCT gave similar AUROCs, showing moderate diagnostic accuracy in patients with early to moderate glaucoma. Further studies are needed to evaluate the ability of these technologies to discriminate between normal and glaucomatous eyes.

  11. Real-time inference of word relevance from electroencephalogram and eye gaze

    Science.gov (United States)

    Wenzel, M. A.; Bogojeski, M.; Blankertz, B.

    2017-10-01

    Objective. Brain-computer interfaces can potentially map the subjective relevance of the visual surroundings, based on neural activity and eye movements, in order to infer the interest of a person in real-time. Approach. Readers looked for words belonging to one out of five semantic categories, while a stream of words passed at different locations on the screen. It was estimated in real-time which words and thus which semantic category interested each reader based on the electroencephalogram (EEG) and the eye gaze. Main results. Words that were subjectively relevant could be decoded online from the signals. The estimation resulted in an average rank of 1.62 for the category of interest among the five categories after a hundred words had been read. Significance. It was demonstrated that the interest of a reader can be inferred online from EEG and eye tracking signals, which can potentially be used in novel types of adaptive software, which enrich the interaction by adding implicit information about the interest of the user to the explicit interaction. The study is characterised by the following novelties. Interpretation with respect to the word meaning was necessary in contrast to the usual practice in brain-computer interfacing where stimulus recognition is sufficient. The typical counting task was avoided because it would not be sensible for implicit relevance detection. Several words were displayed at the same time, in contrast to the typical sequences of single stimuli. Neural activity was related with eye tracking to the words, which were scanned without restrictions on the eye movements.

  12. Abnormal CT scan in a patient with Gilles de la Tourette syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kjaer, M.; Boris, P.; Gadegaard Hansen, L.

    1986-07-01

    In a 28-year-old woman, who presented multiple muscular and vocal tics, typical of Gilles de la Tourette syndrome, CT scans revealed a large porencephalic cyst in the right hemisphere involving the right basal ganglia, as well as contrast enhancement in the region of the left basal ganglia.

  13. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  14. B-lines with Lung Ultrasound: The Optimal Scan Technique at Rest and During Stress.

    Science.gov (United States)

    Scali, Maria Chiara; Zagatina, Angela; Simova, Iana; Zhuravskaya, Nadezhda; Ciampi, Quirino; Paterni, Marco; Marzilli, Mario; Carpeggiani, Clara; Picano, Eugenio

    2017-11-01

    Various lung ultrasound (LUS) scanning modalities have been proposed for the detection of B-lines, also referred to as ultrasound lung comets, which are an important indication of extravascular lung water at rest and after exercise stress echo (ESE). The aim of our study was to assess the lung water spatial distribution (comet map) at rest and after ESE. We performed LUS at rest and immediately after semi-supine ESE in 135 patients (45 women, 90 men; age 62 ± 12 y, resting left ventricular ejection fraction = 41 ± 13%) with known or suspected heart failure or coronary artery disease. B-lines were measured by scanning 28 intercostal spaces (ISs) on the antero-lateral chest, 2nd-5th IS, along with the midaxillary (MA), anterior axillary (AA), mid-clavicular (MC) and parasternal (PS) lines. Complete 28-region, 16-region (3rd and 4th IS), 8-region (3rd IS), 4-region (3rd IS, only AA and MA) and 1-region (left 3rd IS, MA) scans were analyzed. In each space, the B-lines were counted from 0 = black lung to 10 = white lung. Interpretable images were obtained in all spaces (feasibility = 100 %). B-lines (>0 in at least 1 space) were present at ESE in 93 patients (69%) and absent in 42. More B-lines were found in the 3rd IS and along AA and MA lines. The B-line cumulative distribution was symmetric at rest (right/left = 1.10) and asymmetric with left lung predominance during stress (right/left = 0.67). The correlation of per-patient B-line number between 28-S and 16-S (R 2  = 0.9478), 8-S (R 2  = 0.9478) and 4-S scan (R 2  = 0.9146) was excellent, but only good with 1-S (R 2  = 0.8101). The average imaging and online analysis time were 5 s per space. In conclusion, during ESE, the comet map of lung water accumulation follows a predictable spatial pattern with wet spots preferentially aligned with the third IS and along the AA and MA lines. The time-saving 4-region scan is especially convenient during stress, simply dismissing dry regions and

  15. Why Do Eyes Water?

    Science.gov (United States)

    ... for Educators Search English Español Why Do Eyes Water? KidsHealth / For Kids / Why Do Eyes Water? What's ... coming out of your nose. Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  16. Scanning and Deep Processing of Information in Hypertext: An Eye Tracking and Cued Retrospective Think-Aloud Study

    Science.gov (United States)

    Salmerón, L.; Naumann, J.; García, V.; Fajardo, I.

    2017-01-01

    When students solve problems on the Internet, they have to find a balance between quickly scanning large sections of information in web pages and deeply processing those that are relevant for the task. We studied how high school students articulate scanning and deeper processing of information while answering questions using a Wikipedia document,…

  17. Visual Scanning Patterns and Executive Function in Relation to Facial Emotion Recognition in Aging

    Science.gov (United States)

    Circelli, Karishma S.; Clark, Uraina S.; Cronin-Golomb, Alice

    2012-01-01

    Objective The ability to perceive facial emotion varies with age. Relative to younger adults (YA), older adults (OA) are less accurate at identifying fear, anger, and sadness, and more accurate at identifying disgust. Because different emotions are conveyed by different parts of the face, changes in visual scanning patterns may account for age-related variability. We investigated the relation between scanning patterns and recognition of facial emotions. Additionally, as frontal-lobe changes with age may affect scanning patterns and emotion recognition, we examined correlations between scanning parameters and performance on executive function tests. Methods We recorded eye movements from 16 OA (mean age 68.9) and 16 YA (mean age 19.2) while they categorized facial expressions and non-face control images (landscapes), and administered standard tests of executive function. Results OA were less accurate than YA at identifying fear (precognition of sad expressions and with scanning patterns for fearful, sad, and surprised expressions. Conclusion We report significant age-related differences in visual scanning that are specific to faces. The observed relation between scanning patterns and executive function supports the hypothesis that frontal-lobe changes with age may underlie some changes in emotion recognition. PMID:22616800

  18. Exploratory eye movements to pictures in childhood-onset schizophrenia and attention-deficit/hyperactivity disorder (ADHD).

    Science.gov (United States)

    Karatekin, C; Asarnow, R F

    1999-02-01

    We investigated exploratory eye movements to thematic pictures in schizophrenic, attention-deficit/hyperactivity disorder (ADHD), and normal children. For each picture, children were asked three questions varying in amount of structure. We tested if schizophrenic children would stare or scan extensively and if their scan patterns were differentially affected by the question. Time spent viewing relevant and irrelevant regions, fixation duration (an estimate of processing rate), and distance between fixations (an estimate of breadth of attention) were measured. ADHD children showed a trend toward shorter fixations than normals on the question requiring the most detailed analysis. Schizophrenic children looked at fewer relevant, but not more irrelevant, regions than normals. They showed a tendency to stare more when asked to decide what was happening but not when asked to attend to specific regions. Thus, lower levels of visual attention (e.g., basic control of eye movements) were intact in schizophrenic children. In contrast, they had difficulty with top-down control of selective attention in the service of self-guided behavior.

  19. Perceptions of Eye Health and Eye Health Services among Adults Attending Outreach Eye Care Clinics in Papua New Guinea.

    Science.gov (United States)

    Burnett, Anthea; Yu, Mitasha; Paudel, Prakash; Naduvilath, Thomas; Fricke, Tim R; Hani, Yvonne; Garap, Jambi

    2015-01-01

    To determine how people attending outreach eye care clinics in Papua New Guinea (PNG) perceive eye health and eye health services. An interview-based questionnaire was administrated to a convenience sample of 614 adult participants across four provinces and perceptions of eye health and eye health services were recorded. Presenting and near visual acuity were measured and cause of visual impairment (VI) determined. In this sample, 113/614 participants (18.4%) presented with distance VI, 16 (2.6%) with distance blindness, and 221 (47.6%) with near VI. Older participants and those with near VI were more likely to indicate that it is hard to have an eye examination due to travel time, lack of transport and transport costs. Female participants and those from underserved areas were more likely to report shame and fear of jealousy from others when asked about their attitudes towards spectacles. Participants reporting that they were willing to pay higher amounts for testing and spectacles/treatment also reported higher education levels, higher household incomes and were more likely to be male. A quarter of participants (25.9%) indicated that they did not like having an eye examination because their reading and writing was poor. People attending outreach eye care clinics in PNG reported finding it difficult to attend eye health services due to transport difficulties and anticipated high costs. Negative attitudes towards spectacles were also prevalent, and negative perceptions appeared more frequently among older participants and those with less education.

  20. Pigment dispersion glaucoma induced by the chafing effect of intraocular lens haptics in Asian eyes.

    Science.gov (United States)

    Hong, Ying; Sun, Yan-Xiu; Qi, Hong; Zhou, Ji-Chao; Hao, Yan-Sheng

    2013-03-01

    To study the possible mechanism and treatment for pigment dispersion glaucoma (PDG) caused by single-piece acrylic (SPA) intraocular lens (IOL) ciliary sulcus fixation in Asian eyes. Patients referred for PDG caused by SPA IOL ciliary sulcus fixation to our hospital from April 2005 to June 2011 were included. The patients' general information, IOL type, interval between initial surgery and PDG occurrence, examination findings, antiglaucoma medicine regimen and surgical interventions were recorded. In total, six eyes from five Chinese patients were included in this study. The intraocular pressure (IOP) increased 19-30 days after cataract surgery and was not satisfactorily controlled with antiglaucoma medication. Dense pigmentation was deposited on the IOLs and on the anterior chamber angle. IOL haptic chafing was noted on the rear iris surface. IOL repositioning in the capsular bag was performed in three eyes and was combined with trabeculectomy in two eyes with progressive glaucoma. An IOL exchange with three-piece IOL ciliary sulcus fixation was performed in the other three eyes. Scanning electron microscopy of the explanted IOLs demonstrated a rough edge on the IOL haptics. SPA IOLs were not suitable for ciliary sulcus fixation. The chafing effect of the IOL haptics on the posterior iris pigment epithelium could induce PDG in Asian eyes. IOLs should be positioned in the capsular bag or a three-piece IOL should be used instead.

  1. Feasibility of utilizing a commercial eye tracker to assess electronic health record use during patient simulation.

    Science.gov (United States)

    Gold, Jeffrey Allen; Stephenson, Laurel E; Gorsuch, Adriel; Parthasarathy, Keshav; Mohan, Vishnu

    2016-09-01

    Numerous reports describe unintended consequences of electronic health record implementation. Having previously described physicians' failures to recognize patient safety issues within our electronic health record simulation environment, we now report on our use of eye and screen-tracking technology to understand factors associated with poor error recognition during an intensive care unit-based electronic health record simulation. We linked performance on the simulation to standard eye and screen-tracking readouts including number of fixations, saccades, mouse clicks and screens visited. In addition, we developed an overall Composite Eye Tracking score which measured when, where and how often each safety item was viewed. For 39 participants, the Composite Eye Tracking score correlated with performance on the simulation (p = 0.004). Overall, the improved performance was associated with a pattern of rapid scanning of data manifested by increased number of screens visited (p = 0.001), mouse clicks (p = 0.03) and saccades (p = 0.004). Eye tracking can be successfully integrated into electronic health record-based simulation and provides a surrogate measure of cognitive decision making and electronic health record usability. © The Author(s) 2015.

  2. Measurement and comparison of left ventricular ejection fraction utilizing first transit and gated scintiangiography

    International Nuclear Information System (INIS)

    Fletcher, J.W.; Herbig, F.K.; Daly, J.L.; Walter, K.E.

    1975-01-01

    Paired serial radionuclide scans were used for determinations of left ventricular ejection fraction (LVEF) in open chest dogs with constant cardiac output and varying ventricular rates following the left atrial injection of 99m-Tc human serum albumin. Values of LVEF obtained by first transit (high frequency) data analysis and ECG-gated scintiphotography were obtained over a wide range of ventricular rate and stroke volume. The results of this study show no significant difference in LVEF as determined by both of these methods of data acquisition and analysis and demonstrate the feasibility of rapid serial determination of LVEF by radioisotope techniques

  3. Black Eye

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  4. The evolutionary psychology of left and right: costs and benefits of lateralization.

    Science.gov (United States)

    Vallortigara, Giorgio

    2006-09-01

    Why do the left and right sides of the vertebrate brain play different functions? Having a lateralized brain, in which each hemisphere carries out different functions, is ubiquitous among vertebrates. The different specialization of the left and right side of the brain may increase brain efficiency--and some evidence for that is reported here. However, lateral biases due to brain lateralization (such as preferences in the use of a limb or, in animals with laterally placed eyes, of a visual hemifield) usually occur at the population level, with most individuals showing similar direction of bias. Individual brain efficiency does not require the alignment of lateralization in the population. Why then are not left--and right-type individuals equally common? Not only humans, but most vertebrates show a similar pattern. For instance, in the paper I report evidence that most toads, chickens, and fish react faster when a predator approaches from the left. I argue that invoking individual brain efficiency (lateralization may increase fitness), evolutionary chance or direct genetic mechanisms cannot explain this widespread pattern. Instead, using concepts from mathematical theory of games, I show that alignment of lateralization at the population level may arise as an "evolutionarily stable strategy" when individually asymmetrical organisms must coordinate their behavior with that of other asymmetrical organisms. Thus, the population structure of lateralization may result from genes specifying the direction of asymmetries which have been selected under "social" pressures.

  5. A Protective Eye Shield for Prevention of Media Opacities during Small Animal Ocular Imaging

    Science.gov (United States)

    Bell, Brent A.; Kaul, Charles; Hollyfield, Joe G.

    2014-01-01

    Optical coherence tomography (OCT), scanning laser ophthalmoscopy (SLO) and other non-invasive imaging techniques are increasingly used in eye research to document disease-related changes in rodent eyes. Corneal dehydration is a major contributor to the formation of ocular opacities that can limit the repeated application of these techniques to individual animals. General anesthesia is usually required for imaging, which is accompanied by the loss of the blink reflex. As a consequence, the tear film cannot be maintained, drying occurs and the cornea becomes dehydrated. Without supplemental hydration, structural damage to the cornea quickly follows. Soon thereafter, anterior lens opacities can also develop. Collectively these changes ultimately compromise image quality, especially for studies involving repeated use of the same animal over several weeks or months. To minimize these changes, a protective shield was designed for mice and rats that prevent ocular dehydration during anesthesia. The eye shield, along with a semi-viscous ophthalmic solution, is placed over the corneas as soon as the anesthesia immobilizes the animal. Eye shields are removed for only the brief periods required for imaging and then reapplied before the fellow eye is examined. As a result, the corneal surface of each eye is exposed only for the time required for imaging. The device and detailed methods described here minimize the corneal and lens changes associated with ocular surface desiccation. When these methods are used consistently, high quality images can be obtained repeatedly from individual animals. PMID:25245081

  6. Abnormal CT scan in a patient with Gilles de la Tourette syndrome

    International Nuclear Information System (INIS)

    Kjaer, M.; Boris, P.; Gadegaard Hansen, L.

    1986-01-01

    In a 28-year-old woman, who presented multiple muscular and vocal tics, typical of Gilles de la Tourette syndrome, CT scans revealed a large porencephalic cyst in the right hemisphere involving the right basal ganglia, as well as contrast enhancement in the region of the left basal ganglia. (orig.)

  7. Fish eye optics

    Science.gov (United States)

    Hudec, R.; Michalova, S.

    2017-07-01

    We report on small student (high—school) project of the Czech Academy of Sciences dealing with animal (fish) eyes and possible application in science and technology. Albeit most fishes have refractive eyes, the recent discoveries confirm that some fishes have reflective eyes with strange arrangements as well.

  8. [Keratomycosis due to Fusarium oxysporum treated with the combination povidone iodine eye drops and oral fluconazole].

    Science.gov (United States)

    Diongue, K; Sow, A S; Nguer, M; Seck, M C; Ndiaye, M; Badiane, A S; Ndiaye, J M; Ndoye, N W; Diallo, M A; Diop, A; Ndiaye, Y D; Dieye, B; Déme, A; Ndiaye, I M; Ndir, O; Ndiaye, D

    2015-12-01

    In developing countries where systemic antifungal are often unavailable, treatment of filamentous fungi infection as Fusarium is sometimes very difficult to treat. We report the case of a keratomycosis due to Fusarium oxysporum treated by povidone iodine eye drops and oral fluconazole. The diagnosis of abscess in the cornea was retained after ophthalmological examination for a 28-year-old man with no previous ophthalmological disease, addressed to the Ophthalmological clinic at the University Hospital Le Dantec in Dakar for a left painful red eye with decreased visual acuity lasting for 15 days. The patient did not receive any foreign body into the eye. Samples by corneal scraping were made for microbiological analysis and the patient was hospitalized and treated with a reinforced eye drops based treatment (ceftriaxone+gentamicin). The mycological diagnosis revealed the presence of a mold: F. oxysporum, which motivated the replacement of the initial treatment by eye drops containing iodized povidone solution at 1% because of the amphotericin B unavailability. Due to the threat of visual loss, oral fluconazole was added to the local treatment with eye drops povidone iodine. The outcome was favorable with a healing abscess and visual acuity amounted to 1/200th. Furthermore, we noted sequels such as pannus and pillowcase. The vulgarization of efficient topical antifungal in developing countries would be necessary to optimize fungal infection treatment. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  9. Left is right and right is wrong: fluorodeoxyglucose uptake in left hemi-diaphragm due to right phrenic nerve palsy

    International Nuclear Information System (INIS)

    Joshi, Prathamesh; Lele, Vikram

    2013-01-01

    A 36-year-old Indian man, a recently diagnosed case of the right lung carcinoma underwent fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) for staging of the malignancy. PET/CT showed increased FDG uptake in the right lung mass, consistent with the known primary tumor. Right hemidiaphragm was found to be elevated on CT, suggesting right diaphragmatic paresis. The PET scan demonstrated asymmetric, intense FDG uptake in the left hemidiaphragm and accessory muscles of respiration, which was possibly due to compensatory increased workload related to contralateral right diaphragmatic paresis. The right diaphragmatic paresis was hypothesized to be caused by phrenic nerve palsy by right lung neoplasm. (author)

  10. Left is right and right is wrong: Fluorodeoxyglucose uptake in left hemi-diaphragm due to right phrenic nerve palsy.

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram

    2013-01-01

    A 36-year-old Indian man, a recently diagnosed case of the right lung carcinoma underwent fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) for staging of the malignancy. PET/CT showed increased FDG uptake in the right lung mass, consistent with the known primary tumor. Right hemidiaphragm was found to be elevated on CT, suggesting right diaphragmatic paresis. The PET scan demonstrated asymmetric, intense FDG uptake in the left hemidiaphragm and accessory muscles of respiration, which was possibly due to compensatory increased workload related to contralateral right diaphragmatic paresis. The right diaphragmatic paresis was hypothesized to be caused by phrenic nerve palsy by right lung neoplasm.

  11. Adenocarcinoma of urethra presenting metastasis to eyes: a case report

    International Nuclear Information System (INIS)

    Lages, Rafael Bandeira; Sousa, Rodrigo Beserra; Santos, Lina Gomes dos; Vieira, Sabas Carlos; Tavares, Marilia Buenos Aires Cabral

    2010-01-01

    Primary urethral carcinoma is extremely rare, accounting for less than 1% of all female genitourinary tract cancers. To the best of our knowledge, this patient is the first reported case of primary urethral carcinoma presenting metastasis to eyes. The diagnosis of metastasis involving the choroids should be suspected in patient with history of carcinoma and a decreased visual acuity or any other visual symptom. Case presentation: A 43-year-old woman underwent a total hysterectomy, cystectomy and bilateral pelvic lymphadenectomy due a primary adenocarcinoma of the proximal urethra. Adjuvant pelvic radiotherapy and six cycles of chemotherapy using cisplatin were performed. The patient made follow-up with no evidence of oncologic disease. However, nine months later, the patient reported visual alterations. Ophthalmoloscopic examination showed choroid lesions in both eyes that were compatible with metastatic choroids tumor and nuclear magnetic resonance suggested bilateral retinal metastasis and left meningioma parasagittal in parietal region. She was undergoing a new palliative chemotherapy, but the disease developed and there were metastasis to bone four months later. The patient died fourteen months after the surgery. (author)

  12. Adenocarcinoma of urethra presenting metastasis to eyes: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lages, Rafael Bandeira; Sousa, Rodrigo Beserra; Santos, Lina Gomes dos; Vieira, Sabas Carlos, E-mail: rafaelblages@gmail.co [Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil); Tavares, Marilia Buenos Aires Cabral [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Hospital Universitario Walter Cantidio; Valenca, Rodrigo Jose de Vasconcelos [Hospital Sao Marcos (HSM), Teresina, PI (Brazil)

    2010-07-01

    Primary urethral carcinoma is extremely rare, accounting for less than 1% of all female genitourinary tract cancers. To the best of our knowledge, this patient is the first reported case of primary urethral carcinoma presenting metastasis to eyes. The diagnosis of metastasis involving the choroids should be suspected in patient with history of carcinoma and a decreased visual acuity or any other visual symptom. Case presentation: A 43-year-old woman underwent a total hysterectomy, cystectomy and bilateral pelvic lymphadenectomy due a primary adenocarcinoma of the proximal urethra. Adjuvant pelvic radiotherapy and six cycles of chemotherapy using cisplatin were performed. The patient made follow-up with no evidence of oncologic disease. However, nine months later, the patient reported visual alterations. Ophthalmoloscopic examination showed choroid lesions in both eyes that were compatible with metastatic choroids tumor and nuclear magnetic resonance suggested bilateral retinal metastasis and left meningioma parasagittal in parietal region. She was undergoing a new palliative chemotherapy, but the disease developed and there were metastasis to bone four months later. The patient died fourteen months after the surgery. (author)

  13. Molecular mechanism of ocular surface damage: application to an in vitro dry eye model on human corneal epithelium.

    Science.gov (United States)

    Meloni, Marisa; De Servi, Barbara; Marasco, Daniela; Del Prete, Salvatore

    2011-01-12

    The present study was concerned with the development of a new experimental model of dry eye using human reconstructed in vitro corneal epithelium (HCE). The model is based on the use of adapted culture conditions that induce relevant modifications at the cellular and molecular level thus mimicking dry eye. The HCE model was maintained in a controlled environmental setting (relative humidity eye. The evolution of the dry eye condition was assessed by histology, immunohistochemistry staining, scanning electron microscopy, and gene expression by using TaqMan gene assay technology (mucin-4 [MUC4], matrix metallopeptidase-9 [MMP9], tumor necrosis factor-α [TNF-α], and defensin β-2 [DEFB2). The effects of different commercially available tear substitutes on the induced dry eye condition were tested. This in vitro dry eye HCE model, that was well established within 24 h, has the characteristic features of a dry eye epithelium and could be satisfactorily used for preliminary assessment of the protective activity of some artificial tears. The transcriptional study of selected biomarkers showed an increase in MUC4, MMP9, TNF-α, and hBD-2 (DEFB2) gene expression. By using a dynamic approach, we were able to define a biomarker gene signature of dry eye-induced effects that could be predictive of corneal damage in vivo and to discriminate the efficacy among different commercial artificial tears.

  14. The eye amputated - consequences of eye amputation with emphasis on clinical aspects, phantom eye syndrome and quality of life

    DEFF Research Database (Denmark)

    Rasmussen, Marie Louise Roed

    2010-01-01

    In this thesis the term eye amputation (EA) covers the removing of an eye by: evisceration, enucleation and exenteration. Amputation of an eye is most frequently the end-stage in a complicated disease, or the primary treatment in trauma and neoplasm. In 2010 the literature is extensive due...... to knowledge about types of surgery, implants and surgical technique. However, not much is known about the time past surgery. THE PURPOSE OF THE PHD THESIS WAS: To identify the number of EA, the causative diagnosis and the indication for surgical removal of the eye, the chosen surgical technique...... and to evaluate a possible change in surgical technique in Denmark from 1996 until 2003 (paper I); To describe the phantom eye syndrome and its prevalence of visual hallucinations, phantom pain and phantom sensations (paper II); To characterise the quality of phantom eye pain, including its intensity...

  15. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    Directory of Open Access Journals (Sweden)

    J. J. Gu

    2006-01-01

    Full Text Available Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the control system to drive the artificial eye to move with the natural eye. The second generation model removes the impractical usage of the eye glass frame and uses the human brain EOG (electro-ocular-graph signal picked up by electrodes placed on the sides of a person's temple to carry out the same eye movement detection and control tasks as mentioned above. Theoretical issues on sensor failure detection and recovery, and signal processing techniques used in sensor data fusion, are studied using statistical methods and artificial neural network based techniques. In addition, practical control system design and implementation using micro-controllers are studied and implemented to carry out the natural eye movement detection and artificial robotic eye control tasks. Simulation and experimental studies are performed, and the results are included to demonstrate the effectiveness of the research project reported in this paper.

  16. Detection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation

    Science.gov (United States)

    Medeiros, Felipe A.; Alencar, Luciana M.; Zangwill, Linda M.; Bowd, Christopher; Vizzeri, Gianmarco; Sample, Pamela A.; Weinreb, Robert N.

    2010-01-01

    Purpose To evaluate the ability of scanning laser polarimetry with variable corneal compensation to detect progressive retinal nerve fiber layer (RNFL) loss in glaucoma patients and patients suspected of having the disease. Methods This was an observational cohort study that included 335 eyes of 195 patients. Images were obtained annually with the GDx VCC scanning laser polarimeter, along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. The median follow-up time was 3.94 years. Progression was determined using commercial software for SAP and by masked assessment of optic disc stereophotographs performed by expert graders. Random coefficient models were used to evaluate the relationship between RNFL thickness measurements over time and progression as determined by SAP and/or stereophotographs. Results From the 335 eyes, 34 (10%) showed progression over time by stereophotographs and/or SAP. Average GDx VCC measurements decreased significantly over time for both progressors as well as non-progressors. However, the rate of decline was significantly higher in the progressing group (−0.70 μm/year) compared to the non-progressing group (−0.14 μm/year; P = 0.001). Black race and male sex were significantly associated with higher rates of RNFL loss during follow-up. Conclusions The GDx VCC scanning laser polarimeter was able to identify longitudinal RNFL loss in eyes that showed progression in optic disc stereophotographs and/or visual fields. These findings suggest that this technology could be useful to detect and monitor progressive disease in patients with established diagnosis of glaucoma or suspected of having the disease. PMID:19029038

  17. Eye Anatomy

    Science.gov (United States)

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  18. Eye Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of retinal detachment, a ...

  19. Visual rehabilitation: visual scanning, multisensory stimulation and vision restoration trainings

    Directory of Open Access Journals (Sweden)

    Neil M. Dundon

    2015-07-01

    Full Text Available Neuropsychological training methods of visual rehabilitation for homonymous vision loss caused by postchiasmatic damage fall into two fundamental paradigms: compensation and restoration. Existing methods can be classified into three groups: Visual Scanning Training (VST, Audio-Visual Scanning Training (AViST and Vision Restoration Training (VRT. VST and AViST aim at compensating vision loss by training eye scanning movements, whereas VRT aims at improving lost vision by activating residual visual functions by training light detection and discrimination of visual stimuli. This review discusses the rationale underlying these paradigms and summarizes the available evidence with respect to treatment efficacy. The issues raised in our review should help guide clinical care and stimulate new ideas for future research uncovering the underlying neural correlates of the different treatment paradigms. We propose that both local within-system interactions (i.e., relying on plasticity within peri-lesional spared tissue and changes in more global between-system networks (i.e., recruiting alternative visual pathways contribute to both vision restoration and compensatory rehabilitation that ultimately have implications for the rehabilitation of cognitive functions.

  20. Effects of Repetitive Transcranial Magnetic Stimulation in Performing Eye-Hand Integration Tasks: Four Preliminary Studies with Children Showing Low-Functioning Autism

    Science.gov (United States)

    Panerai, Simonetta; Tasca, Domenica; Lanuzza, Bartolo; Trubia, Grazia; Ferri, Raffaele; Musso, Sabrina; Alagona, Giovanna; Di Guardo, Giuseppe; Barone, Concetta; Gaglione, Maria P.; Elia, Maurizio

    2014-01-01

    This report, based on four studies with children with low-functioning autism, aimed at evaluating the effects of repetitive transcranial magnetic stimulation delivered on the left and right premotor cortices on eye-hand integration tasks; defining the long-lasting effects of high-frequency repetitive transcranial magnetic stimulation; and…