WorldWideScience

Sample records for large eqs ms

  1. EQ3/6: status and applications

    Energy Technology Data Exchange (ETDEWEB)

    Wolery, T.J.; Isherwood, D.J.; Jackson, K.J.; Delany, J.M.; Puigdomenech, I.

    1984-12-01

    EQ3/6 is a set of related computer codes and data files for use in geochemical modeling of aqueous systems. The EQ3/6 package centers around two large computer codes, EQ3NR and EQ6, which are supported by a common thermodynamic data base. EQ3NR is a speciation-solubility code, whose function is to compute a model of the state of an aqueous solution. This code is very flexible in terms of the input that it will accept. EQ6 is a reaction-path code, which calculates models of changes in aqueous systems as they proceed toward a state of overall chemical equilibrium. EQ3/6 prior to FY83 had no capability for modeling brines, because the approximations for calculating the thermodynamic activity of water and the activity coefficients of the solute species were restricted to low ionic strengths ({le} 1.0 molal). An option has been added to use Pitzer`s equations for such calculations. At present, EQ3/6 contains two alternate Pitzer coefficient data bases. Several improvements have been made to the EQ6 code. Prior to FY83, the code could run models of mineral dissolution kinetics, but could not calculate models of precipitation kinetics. This problem has been overcome by additional code development. The speed of non-kinetic EQ6 calculations has recently been enhanced by the creation of two new calculational modes, economy mode and super economy mode. A calculational mode to simulate systems open to large gas reservoirs has also been developed. 34 references.

  2. Correspondence between EQ-5D health state classifications and EQ VAS scores

    Directory of Open Access Journals (Sweden)

    Whynes David K

    2008-11-01

    Full Text Available Abstract Background The EQ-5D health-related quality of life instrument comprises a health state classification followed by a health evaluation using a visual analogue scale (VAS. The EQ-5D has been employed frequently in economic evaluations, yet the relationship between the two parts of the instrument remains ill-understood. In this paper, we examine the correspondence between VAS scores and health state classifications for a large sample, and identify variables which contribute to determining the VAS scores independently of the health states as classified. Methods A UK trial of management of low-grade abnormalities detected on screening for cervical pre-cancer (TOMBOLA provided EQ-5D data for over 3,000 women. Information on distress and multi-dimensional health locus of control had been collected using other instruments. A linear regression model was fitted, with VAS score as the dependent variable. Independent variables comprised EQ-5D health state classifications, distress, locus of control, and socio-demographic characteristics. Equivalent EQ-5D and distress data, collected at twelve months, were available for over 2,000 of the women, enabling us to predict changes in VAS score over time from changes in EQ-5D classification and distress. Results In addition to EQ-5D health state classification, VAS score was influenced by the subject's perceived locus of control, and by her age, educational attainment, ethnic origin and smoking behaviour. Although the EQ-5D classification includes a distress dimension, the independent measure of distress was an additional determinant of VAS score. Changes in VAS score over time were explained by changes in both EQ-5D severities and distress. Women allocated to the experimental management arm of the trial reported an increase in VAS score, independently of any changes in health state and distress. Conclusion In this sample, EQ VAS scores were predictable from the EQ-5D health state classification, although

  3. WebEQ: a web-GIS System to collect, display and query data for the management of the earthquake emergency in Central Italy

    Science.gov (United States)

    Carbone, Gianluca; Cosentino, Giuseppe; Pennica, Francesco; Moscatelli, Massimiliano; Stigliano, Francesco

    2017-04-01

    After the strong earthquakes that hit central Italy in recent months, the Center for Seismic Microzonation and its applications (CentroMS) was commissioned by the Italian Department of Civil Protection to conduct the study of seismic microzonation of the territories affected by the earthquake of August 24, 2016. As part of the activities of microzonation, IGAG CNR has created WebEQ, a management tool of the data that have been acquired by all participants (i.e., more than twenty research institutes and university departments). The data collection was organized and divided into sub-areas, assigned to working groups with multidisciplinary expertise in geology, geophysics and engineering. WebEQ is a web-GIS System that helps all the subjects involved in the data collection activities, through tools aimed at data uploading and validation, and with a simple GIS interface to display, query and download geographic data. WebEQ is contributing to the creation of a large database containing geographical data, both vector and raster, from various sources and types: - Regional Technical Map em Geological and geomorphological maps em Data location maps em Maps of microzones homogeneous in seismic perspective and seismic microzonation maps em National strong motion network location. Data loading is done through simple input masks that ensure consistency with the database structure, avoiding possible errors and helping users to interact with the map through user-friendly tools. All the data are thematized through standardized symbologies and colors (Gruppo di lavoro MS 2008), in order to allow the easy interpretation by all users. The data download tools allow data exchange between working groups and the scientific community to benefit from the activities. The seismic microzonation activities are still ongoing. WebEQ is enabling easy management of large amounts of data and will form a basis for the development of tools for the management of the upcoming seismic emergencies.

  4. Demographic characteristics of MS patients in Poland's upper Silesia region.

    Science.gov (United States)

    Pierzchala, Krystyna; Adamczyk-Sowa, Monika; Dobrakowski, Pawel; Kubicka-Baczyk, Katarzyna; Niedziela, Natalia; Sowa, Pawel

    2015-05-01

    In Poland, no national registry of MS patients has yet been introduced. So far, no demographic studies have been conducted in patients with MS in Upper Silesia. The aim of the present study was to evaluate, for the first time, a selected demographic and clinical parameters in MS patients from the Upper Silesia region and compare these characteristics with previously published data from other regions of Poland. 640 patients with clinically defined MS, were prospectively and randomly selected for the study. Social, socio-economic, and demographic data were obtained through a questionnaire study. All subjects performed a self-assessment of their health condition using EQ-5D and EQ-VAS version questionnaires. The ratio of women to men was 2.18. The average age of onset was 29.6 ± 11.1 years; the disease duration was 7.9 ± 4.5 years. The relapsing-remitting form of MS was diagnosed in 73.12%. In 71.25% the onset was monofocal and in 28.75% multifocal disease onset was observed. Among the studied population 339 (52.97%) patients were still employed. A mean EQ-VAS score of 66.11 ± 20.12 was calculated. Results from our study identify for the first time the demographic and clinical characteristics of the Upper Silesia MS population.

  5. Preserving EQ as per CSA N290.13: EQ of equipment for CANDU NPP

    International Nuclear Information System (INIS)

    Bordeleau, H.

    2006-01-01

    EQ is basically a Quality Assurance process that ensures that required safety related equipment will performed their safety functions during accident generating harsh environmental condition. As any good Quality Assurance Program, EQ activities have to be imbedded in the normal tasks of the people at the plant in such a way that it is not an extra concern but part of the things to be assessed and done on a regular basis so that the EQ Status of the equipment will not be compromised. The experience shows us that even with brand new plants there are discrepancies between equipment designed to be installed and that installed (wrong model or wrong instrument). Improper installation was also found. To eliminate these mistakes it is recommended to have a thorough initial inspection during construction or commissioning and later at regular intervals during operation. To avoid new mistakes during maintenance, crews have to be properly qualified and trained on completed procedure with appropriate work report that will required to be scrutinized for possible common cause failure and OPEX report. Procurement and handling of equipment and spare parts require a thorough revision of procurement and storage practices to guarantee proper storage, availability and identification of equipment for EQ replacement. A shelf life program for degradable material shall be implemented. Condition monitoring program could be use to extend life of equipment or as a qualification methods, caution should be use to look very precisely to the critical parameters that need to be monitored and to carefully tailor the monitoring program. EQ program should also consider barriers, they are not EQ equipment; it is usually made out of non-ageing material like metal or concrete. But there could be sealing material used in conjunction with the barriers and these may need special care. The impact of EQ parameters changes related to services conditions, new technical data or condition monitoring has to be

  6. Performance of the EQ-5D and the EQ-5D+C in elderly patients with cognitive impairments

    Directory of Open Access Journals (Sweden)

    Verhey Frans RJ

    2007-06-01

    Full Text Available Abstract Background The EQ-5D is a reliable tool for measuring Health-Related Quality of Life (HRQoL. However, concern has been expressed that it may ignore elements of HRQoL, particularly cognition. In response to this concern, the EQ-5D has been extended with a cognitive dimension (EQ-5D+C. The aim of this study was to compare the performance of the EQ-5D and the EQ-5D+C in elderly patients with cognitive impairments by assessing their construct validity and responsiveness. Methods Data from the MEDICIE study (n = 196 were used, in which all questionnaires were rated by proxies. Results Regarding construct validity, we found similar correlations between the EQ-5D and the Mini Mental State Examination (MMSE and between the EQ-5D+C and the MMSE. Furthermore, both the EQ-5D and the EQ-5D+C were responsive to changes in the MMSE, with the EQ-5D performing slightly better. Conclusion We conclude that the EQ-5D performs well for evaluating HRQoL in a population with cognitive impairments. Based on the results of this explorative study, it does not seem necessary to adjust the current classification system by adding a cognitive dimension. However, in order to compare both instruments regarding utility values, it is necessary to develop a new scoring algorithm for the EQ-5D+C by conducting a general population study. Considering the explorative nature of this study, it is recommended that more aspects of the validity of both the EQ-5D and the EQ-5D+C are explored in patients with cognitive impairments using a more tailored study design.

  7. EQ-5D Portuguese population norms.

    Science.gov (United States)

    Ferreira, Lara Noronha; Ferreira, Pedro L; Pereira, Luis N; Oppe, Mark

    2014-03-01

    The EQ-5D is a widely used preference-based measure. Normative data can be used as references to analyze the effects of healthcare, determine the burden of disease and enable regional or country comparisons. Population norms for the EQ-5D exist for other countries but have not been previously published for Portugal. The purpose of this study was to derive EQ-5D Portuguese population norms. The EQ-5D was applied by phone interview to a random sample of the Portuguese general population (n = 1,500) stratified by age, gender and region. The Portuguese value set was used to derive the EQ-5D index. Mean values were computed by gender and age groups, marital status, educational attainment, region and other variables to obtain the EQ-5D Portuguese norms. Health status declines with advancing age, and women reported worse health status than men. These results are similar to other EQ-5D population health studies. This study provides Portuguese population health-related quality of life data measured by the EQ-5D that can be used as population norms. These norms can be used to inform Portuguese policy makers, health care professionals and researchers in issues related to health care policy and planning and quantification of treatment effects on health status.

  8. Comparing the UK EQ-5D-3L and English EQ-5D-5L Value Sets.

    Science.gov (United States)

    Mulhern, Brendan; Feng, Yan; Shah, Koonal; Janssen, Mathieu F; Herdman, Michael; van Hout, Ben; Devlin, Nancy

    2018-06-01

    Three EQ-5D value sets (EQ-5D-3L, crosswalk, and EQ-5D-5L) are now available for cost-utility analysis in the UK and/or England. The value sets' characteristics differ, and it is important to assess the implications of these differences. The aim of this paper is to compare the three value sets. We carried out analysis comparing the predicted values from each value set, and investigated how differences in health on the descriptive system is reflected in the utility score by assessing the value of adjacent states. We also assessed differences in values using data from patients who completed both EQ-5D-3L and EQ-5D-5L. The distribution of the value sets systematically differed. EQ-5D-5L values were higher than EQ-5D-3L/crosswalk values. The overall range and difference between adjacent states was smaller. In the patient data, the EQ-5D-5L produced higher values across all conditions and there was some evidence that the value sets rank different health conditions in a similar severity order. There are important differences between the value sets. Due to the smaller range of EQ-5D-5L values, the possible change in quality-adjusted life years (QALYs) might be reduced, but they will apply to both control and intervention groups, and will depend on whether the gain is in quality of life, survival, or both. The increased sensitivity of EQ-5D-5L may also favour QALY gains even if the changes in utility are smaller. Further work should assess the impact of the different value sets on cost effectiveness by repeating the analysis on clinical trial data.

  9. Uniform topology on EQ-algebras

    Directory of Open Access Journals (Sweden)

    Yang Jiang

    2017-04-01

    Full Text Available In this paper, we use filters of an EQ-algebra E to induce a uniform structure (E, , and then the part induce a uniform topology in E. We prove that the pair (E, is a topological EQ-algebra, and some properties of (E, are investigated. In particular, we show that (E, is a first-countable, zero-dimensional, disconnected and completely regular space. Finally, by using convergence of nets, the convergence of topological EQ-algebras is obtained.

  10. Mapping onto Eq-5 D for patients in poor health

    Directory of Open Access Journals (Sweden)

    Brazier John E

    2010-11-01

    Full Text Available Abstract Background An increasing amount of studies report mapping algorithms which predict EQ-5 D utility values using disease specific non-preference-based measures. Yet many mapping algorithms have been found to systematically overpredict EQ-5 D utility values for patients in poor health. Currently there are no guidelines on how to deal with this problem. This paper is concerned with the question of why overestimation of EQ-5 D utility values occurs for patients in poor health, and explores possible solutions. Method Three existing datasets are used to estimate mapping algorithms and assess existing mapping algorithms from the literature mapping the cancer-specific EORTC-QLQ C-30 and the arthritis-specific Health Assessment Questionnaire (HAQ onto the EQ-5 D. Separate mapping algorithms are estimated for poor health states. Poor health states are defined using a cut-off point for QLQ-C30 and HAQ, which is determined using association with EQ-5 D values. Results All mapping algorithms suffer from overprediction of utility values for patients in poor health. The large decrement of reporting 'extreme problems' in the EQ-5 D tariff, few observations with the most severe level in any EQ-5 D dimension and many observations at the least severe level in any EQ-5 D dimension led to a bimodal distribution of EQ-5 D index values, which is related to the overprediction of utility values for patients in poor health. Separate algorithms are here proposed to predict utility values for patients in poor health, where these are selected using cut-off points for HAQ-DI (> 2.0 and QLQ C-30 ( Conclusion Mapping algorithms overpredict utility values for patients in poor health but are used in cost-effectiveness analyses nonetheless. Guidelines can be developed on when the use of a mapping algorithms is inappropriate, for instance through the identification of cut-off points. Cut-off points on a disease specific questionnaire can be identified through association

  11. Econometric modelling of multiple self-reports of health states: The switch from EQ-5D-3L to EQ-5D-5L in evaluating drug therapies for rheumatoid arthritis.

    Science.gov (United States)

    Hernández-Alava, Mónica; Pudney, Stephen

    2017-09-01

    EQ-5D is used in cost-effectiveness studies underlying many important health policy decisions. It comprises a survey instrument describing health states across five domains, and a system of utility values for each state. The original 3-level version of EQ-5D is being replaced with a more sensitive 5-level version but the consequences of this change are uncertain. We develop a multi-equation ordinal response model incorporating a copula specification with normal mixture marginals to analyse joint responses to EQ-5D-3L and EQ-5D-5L in a survey of people with rheumatic disease, and use it to generate mappings between the alternative descriptive systems. We revisit a major cost-effectiveness study of drug therapies for rheumatoid arthritis, mapping the original EQ-5D-3L measure onto a 5L valuation basis. Working within a comprehensive, flexible econometric framework, we find that use of simpler restricted specifications can make very large changes to cost-effectiveness estimates with serious implications for decision-making. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Cross-cultural measurement equivalence of the 5-level EQ-5D (EQ-5D-5L) in patients with type 2 diabetes mellitus in Singapore.

    Science.gov (United States)

    Wang, Ye; Tan, Ngiap-Chuan; Tay, Ee-Guan; Thumboo, Julian; Luo, Nan

    2015-07-16

    This study aimed to assess the measurement equivalence of the 5-level EQ-5D (EQ-5D-5L) among the English, Chinese, and Malay versions. A convenience sample of patients with type 2 diabetes mellitus were enrolled from a public primary health care institution in Singapore. The survey questionnaire comprised the EQ-5D-5L and questions assessing participants' socio-demographic and clinical characteristics. Multiple linear regression models were used to assess the difference in EQ-5D-5L index (calculated using an interim algorithm) and EQ-visual analog scale (EQ-VAS) scores across survey language (Chinese vs. English, Malay vs. English, and Malay vs. Chinese). Measurement equivalence was examined by comparing the 90% confidence interval of difference in the EQ-5D-5L index and EQ-VAS scores with a pre-determined equivalence margin. Multiple logistic regression models were used to assess the response patterns of the 5 Likert-type items of the EQ-5D-5L across survey language. Equivalence was demonstrated between the Chinese and English versions and between the Malay and English versions of the EQ-5D-5L index scores. Equivalence was also demonstrated between the Chinese and English versions and between the Malay and Chinese versions of the EQ-VAS scores. Equivalence could not be determined between the Malay and Chinese versions of the EQ-5D-5L index score and between the Malay and English versions of the EQ-VAS score. No significant difference was found in responses to EQ-5D-5L items between any languages, except that patients who chose to complete the Chinese version were more likely to report "no problems" in mobility compared to those who completed the Malay version of the questionnaire. This study provided evidence for the measurement equivalence of the different language versions of EQ-5D-5L in Singapore.

  13. Measurement properties of the EQ-5D-5L compared to the EQ-5D-3L in psoriasis patients.

    Science.gov (United States)

    Poór, Adrienn Katalin; Rencz, Fanni; Brodszky, Valentin; Gulácsi, László; Beretzky, Zsuzsanna; Hidvégi, Bernadett; Holló, Péter; Kárpáti, Sarolta; Péntek, Márta

    2017-12-01

    The purpose of this study is to assess the measurement properties of EQ-5D-5L compared to EQ-5D-3L in psoriasis patients. A cross-sectional survey was carried out at an academic dermatology clinic in Hungary. Psoriasis patients completed the EQ-5D-3L, EQ-5D-5L and Dermatology Life Quality Index (DLQI) questionnaires, and Psoriasis Area and Severity Index (PASI) was assessed. The UK value sets were used to calculate the 3L and 5L index scores. We tested the feasibility, ceiling effect, redistribution properties, the level of inconsistency and informativity (Shannon and Shannon Evenness indices). Spearman's rank-order correlations were performed between EQ-5D, EQ VAS, DLQI and PASI scores. Known-groups validity was evaluated by comparing age groups, clinical subtypes and treatment groups. Mean age of the 238 patients was 47 years, and 36.6% of them received biological therapy. Mean EQ-5D index score was 0.77 (SD: 0.26) with the 3L and 0.84 (SD: 0.19) with the 5L. The overall ceiling effect decreased from 37.1 (3L) to 32.9% (5L). Shannon index improved significantly for most dimensions, but Shannon Evenness index improved only in three dimensions. Compared to the 3L, the 5L version confirmed a better convergent validity with PASI, but not with the DLQI. Known-groups validity was equally demonstrated both for the 5L and 3L. The EQ-5D-5L seems to improve measurement properties by reducing ceiling effects, strengthening correlations with PASI and improving informativity. Follow-up studies are needed to test responsiveness and reliability in psoriasis.

  14. Health-related quality of life measured using the EQ-5D-5L: South Australian population norms.

    Science.gov (United States)

    McCaffrey, Nikki; Kaambwa, Billingsley; Currow, David C; Ratcliffe, Julie

    2016-09-20

    Although a five level version of the widely-used EuroQol 5 dimensions (EQ-5D) instrument has been developed, population norms are not yet available for Australia to inform the future valuation of health in economic evaluations. The aim of this study was to estimate HrQOL normative values for the EQ-5D-5L preference-based measure in a large, randomly selected, community sample in South Australia. The EQ-5D-5L instrument was included in the 2013 South Australian Health Omnibus Survey, an interviewer-administered, face-to-face, cross-sectional survey. Respondents rated their level of impairment across dimensions (mobility, self-care, usual activities, pain/discomfort, and anxiety/depression) and global health rating on a visual analogue scale (EQ-VAS). Utility scores were derived using the newly-developed UK general population-based algorithm and relationships between utility and EQ-VAS scores and socio-demographic factors were also explored using multivariate regression analyses. Ultimately, 2,908 adults participated in the survey (63.4 % participation rate). The mean utility and EQ-VAS scores were 0.91 (95 CI 0.90, 0.91) and 78.55 (95 % CI 77.95, 79.15), respectively. Almost half of respondents reported no problems across all dimensions (42.8 %), whereas only 7.2 % rated their health >90 on the EQ-VAS (100 = the best health you can imagine). Younger age, male gender, longer duration of education, higher annual household income, employment and marriage/de facto relationships were all independent, statistically significant predictors of better health status (p measured with the EQ-VAS. Only age and employment status were associated with higher utility scores, indicating fundamental differences between these measures of health status. This is the first Australian study to apply the EQ-5D-5L in a large, community sample. Overall, findings are consistent with EQ-5D-5L utility and VAS scores reported for other countries and indicate that the majority of South

  15. Large deep neural networks for MS lesion segmentation

    Science.gov (United States)

    Prieto, Juan C.; Cavallari, Michele; Palotai, Miklos; Morales Pinzon, Alfredo; Egorova, Svetlana; Styner, Martin; Guttmann, Charles R. G.

    2017-02-01

    Multiple sclerosis (MS) is a multi-factorial autoimmune disorder, characterized by spatial and temporal dissemination of brain lesions that are visible in T2-weighted and Proton Density (PD) MRI. Assessment of lesion burden and is useful for monitoring the course of the disease, and assessing correlates of clinical outcomes. Although there are established semi-automated methods to measure lesion volume, most of them require human interaction and editing, which are time consuming and limits the ability to analyze large sets of data with high accuracy. The primary objective of this work is to improve existing segmentation algorithms and accelerate the time consuming operation of identifying and validating MS lesions. In this paper, a Deep Neural Network for MS Lesion Segmentation is implemented. The MS lesion samples are extracted from the Partners Comprehensive Longitudinal Investigation of Multiple Sclerosis (CLIMB) study. A set of 900 subjects with T2, PD and a manually corrected label map images were used to train a Deep Neural Network and identify MS lesions. Initial tests using this network achieved a 90% accuracy rate. A secondary goal was to enable this data repository for big data analysis by using this algorithm to segment the remaining cases available in the CLIMB repository.

  16. Sensitivity analysis of EQ3

    International Nuclear Information System (INIS)

    Horwedel, J.E.; Wright, R.Q.; Maerker, R.E.

    1990-01-01

    A sensitivity analysis of EQ3, a computer code which has been proposed to be used as one link in the overall performance assessment of a national high-level waste repository, has been performed. EQ3 is a geochemical modeling code used to calculate the speciation of a water and its saturation state with respect to mineral phases. The model chosen for the sensitivity analysis is one which is used as a test problem in the documentation of the EQ3 code. Sensitivities are calculated using both the CHAIN and ADGEN options of the GRESS code compiled under G-float FORTRAN on the VAX/VMS and verified by perturbation runs. The analyses were performed with a preliminary Version 1.0 of GRESS which contains several new algorithms that significantly improve the application of ADGEN. Use of ADGEN automates the implementation of the well-known adjoint technique for the efficient calculation of sensitivities of a given response to all the input data. Application of ADGEN to EQ3 results in the calculation of sensitivities of a particular response to 31,000 input parameters in a run time of only 27 times that of the original model. Moreover, calculation of the sensitivities for each additional response increases this factor by only 2.5 percent. This compares very favorably with a running-time factor of 31,000 if direct perturbation runs were used instead. 6 refs., 8 tabs

  17. EQ DAN AQ DALAM PENGEMBANGAN PROFESIONALISME PUSTAKAWAN

    Directory of Open Access Journals (Sweden)

    Aris Nurohman

    2016-05-01

    EQ and AQ in developing of librarian profession will aid to self control and emotion management. By EQ and AQ will aid librarians able to manage self complexity, so it will bear intellectual, skill, behavior, leadership, good personality, smart, creative, progressive and broad horizon.

  18. EQ3/6 software test and verification report 9/94

    International Nuclear Information System (INIS)

    Kishi, T.

    1996-02-01

    This document is the Software Test and Verification Report (STVR) for the EQ3/6 suite of codes as stipulated in the Individual Software Plan for Initial Qualification of EQ3/6 (ISP-NF-07, Revision 1, 11/25/92). The software codes, EQPT, EQ3NR, EQ6, and the software library EQLIB constitute the EQ3/6 software package. This software test and verification project for EQ3/6 was started under the requirements of the LLNL Yucca Mountain Project Software Quality Assurance Plan (SQAP), Revision 0, December 14, 1989, but QP 3.2, Revision 2, June 21, 1994 is now the operative controlling procedure. This is a ''V and V'' report in the language of QP 3.2, Revision 2. Because the author of this report does not have a background in geochemistry, other technical sources were consulted in order to acquire some familiarity with geochemisty, the terminology minology involved, and to review comparable computational methods especially, geochemical aqueous speciation-solubility calculations. The software for the EQ3/6 package consists of approximately 47,000 lines of FORTRAN77 source code and nine on platforms ranging from workstations to supercomputers. The physical control of EQ3/6 software package and documentation is on a SUN SPARC station. Walkthroughs of each principal software packages, EQPT, EQ3NR, and EQ6 were conducted in order to understand the computational procedures involved, to determine any commonality in procedures, and then to establish a plan for the test and verification of EQ3/6. It became evident that all three phases depended upon solving an n x n matrix by the Newton-Raphson Method. Thus, a great deal of emphasis on the test and verification of this procedure was carried out on the first code in the software package EQPT

  19. EQ3/6 software test and verification report 9/94

    Energy Technology Data Exchange (ETDEWEB)

    Kishi, T.

    1996-02-01

    This document is the Software Test and Verification Report (STVR) for the EQ3/6 suite of codes as stipulated in the Individual Software Plan for Initial Qualification of EQ3/6 (ISP-NF-07, Revision 1, 11/25/92). The software codes, EQPT, EQ3NR, EQ6, and the software library EQLIB constitute the EQ3/6 software package. This software test and verification project for EQ3/6 was started under the requirements of the LLNL Yucca Mountain Project Software Quality Assurance Plan (SQAP), Revision 0, December 14, 1989, but QP 3.2, Revision 2, June 21, 1994 is now the operative controlling procedure. This is a ``V and V`` report in the language of QP 3.2, Revision 2. Because the author of this report does not have a background in geochemistry, other technical sources were consulted in order to acquire some familiarity with geochemisty, the terminology minology involved, and to review comparable computational methods especially, geochemical aqueous speciation-solubility calculations. The software for the EQ3/6 package consists of approximately 47,000 lines of FORTRAN77 source code and nine on platforms ranging from workstations to supercomputers. The physical control of EQ3/6 software package and documentation is on a SUN SPARC station. Walkthroughs of each principal software packages, EQPT, EQ3NR, and EQ6 were conducted in order to understand the computational procedures involved, to determine any commonality in procedures, and then to establish a plan for the test and verification of EQ3/6. It became evident that all three phases depended upon solving an n x n matrix by the Newton-Raphson Method. Thus, a great deal of emphasis on the test and verification of this procedure was carried out on the first code in the software package EQPT.

  20. PP: A graphics post-processor for the EQ6 reaction path code

    International Nuclear Information System (INIS)

    Stockman, H.W.

    1994-09-01

    The PP code is a graphics post-processor and plotting program for EQ6, a popular reaction-path code. PP runs on personal computers, allocates memory dynamically, and can handle very large reaction path runs. Plots of simple variable groups, such as fluid and solid phase composition, can be obtained with as few as two keystrokes. Navigation through the list of reaction path variables is simple and efficient. Graphics files can be exported for inclusion in word processing documents and spreadsheets, and experimental data may be imported and superposed on the reaction path runs. The EQ6 thermodynamic database can be searched from within PP, to simplify interpretation of complex plots

  1. Correction to: Comparing the UK EQ-5D-3L and English EQ-5D-5L Value Sets

    NARCIS (Netherlands)

    B. Mulhern (Brendan); Feng, Y. (Yan); K.K. Shah (Koonal); M.F. Janssen (Bas); M. Herdman (Michael); van Hout, B. (Ben); N. Devlin (Nancy)

    2018-01-01

    textabstractThe article Comparing the UK EQ-5D-3L and English EQ-5D-5L Value Sets, written by Brendan Mulhern, Yan Feng, Koonal Shah, Mathieu F. Janssen, Michael Herdman, Ben van Hout, Nancy Devlin was originally published electronically on the publisher’s internet portal (currently SpringerLink) on

  2. Structural equation modeling with EQS basic concepts, applications, and programming

    CERN Document Server

    Byrne, Barbara M

    2013-01-01

    Readers who want a less mathematical alternative to the EQS manual will find exactly what they're looking for in this practical text. Written specifically for those with little to no knowledge of structural equation modeling (SEM) or EQS, the author's goal is to provide a non-mathematical introduction to the basic concepts of SEM by applying these principles to EQS, Version 6.1. The book clearly demonstrates a wide variety of SEM/EQS applications that include confirmatory factor analytic and full latent variable models. Written in a "user-friendly" style, the author "walks" the reader through the varied steps involved in the process of testing SEM models: model specification and estimation, assessment of model fit, EQS output, and interpretation of findings. Each of the book's applications is accompanied by: a statement of the hypothesis being tested, a schematic representation of the model, explanations of the EQS input and output files, tips on how to use the pull-down menus, and the data file upon which ...

  3. Solução concentrada de albumina eqüina na fluidoterapia em eqüinos com desidratação leve a moderada

    OpenAIRE

    Belli,C.B.; Michima,L.E.S.; Latorre,S.M.; Fernandes,W.R.

    2008-01-01

    Avaliou-se o efeito da solução concentrada de albumina eqüina diluída a 5% em solução fisiológica (SF) durante fluidoterapia em eqüinos, após indução de desidratação leve a moderada, utilizando-se cinco eqüinos adultos, sem alterações clínicas. Cada animal passou por dois protocolos de fluidoterapia: apenas com SF (metade sob pressão e metade em fluxo contínuo - grupo-controle); com solução de albumina eqüina e SF (apenas em fluxo contínuo - grupo experimental). Avaliaram-se peso, exame físic...

  4. The EQ3/6 software package for geochemical modeling: Current status

    International Nuclear Information System (INIS)

    Worlery, T.J.; Jackson, K.J.; Bourcier, W.L.; Bruton, C.J.; Viani, B.E.; Knauss, K.G.; Delany, J.M.

    1988-07-01

    EQ3/6 is a software package for modeling chemical and mineralogic interactions in aqueous geochemical systems. The major components of the package are EQ3NR (a speciation-solubility code), EQ6 (a reaction path code), EQLIB (a supporting library), and a supporting thermodynamic data base. EQ3NR calculates aqueous speciation and saturation indices from analytical data. It can also be used to calculate compositions of buffer solutions for use in laboratory experiments. EQ6 computes reaction path models of both equilibrium step processes and kinetic reaction processes. These models can be computed for closed systems and relatively simple open systems. EQ3/6 is useful in making purely theoretical calculations, in designing, interpreting, and extrapolating laboratory experiments, and in testing and developing submodels and supporting data used in these codes. The thermodynamic data base supports calculations over the range 0-300 degree C. 60 refs., 2 figs

  5. The EQ3/6 software package for geochemical modeling: Current status

    Energy Technology Data Exchange (ETDEWEB)

    Wolery, T.J.; Jackson, K.J.; Bourcier, W.L.; Bruton, C.J.; Viani, B.E.; Knauss, K.G.; Delany, J.M.

    1988-07-01

    EQ3/6 is a software package for modeling chemical and mineralogic interactions in aqueous geochemical systems. The major components of the package are EQ3NR (a speciation-solubility code), EQ6 (a reaction path code), EQLIB (a supporting library), and a supporting thermodynamic data base. EQ3NR calculates aqueous speciation and saturation indices from analytical data. It can also be used to calculate compositions of buffer solutions for use in laboratory experiments. EQ6 computes reaction path models of both equilibrium step processes and kinetic reaction processes. These models can be computed for closed systems and relatively simple open systems. EQ3/6 is useful in making purely theoretical calculations, in designing, interpreting, and extrapolating laboratory experiments, and in testing and developing submodels and supporting data used in these codes. The thermodynamic data base supports calculations over the range 0-300{degree}C. 60 refs., 2 figs.

  6. Comparing and transforming PROMIS utility values to the EQ-5D.

    Science.gov (United States)

    Hartman, John D; Craig, Benjamin M

    2018-03-01

    Summarizing patient-reported outcomes (PROs) on a quality-adjusted life year (QALY) scale is an essential component to any economic evaluation comparing alternative medical treatments. While multiple studies have compared PRO items and instruments based on their psychometric properties, no study has compared the preference-based summary of the EQ-5D-3L and Patient Reported Outcomes Measurement Information System (PROMIS-29) instruments. As part of this comparison, a major aim of this manuscript is to transform PROMIS-29 utility values to an EQ-5D-3L scale. A nationally representative survey of 2623 US adults completed the 29-item PROMIS health profile instrument (PROMIS-29) and the 3-level version of the EQ-5D instrument (EQ-5D-3L). Their responses were summarized on a health utility scale using published estimates. Using regression analysis, PROMIS-29 and EQ-5D-3L utility weights were compared with each other as well as with self-reported general health. PROMIS-29 utility weights were much lower than the EQ-5D-3L weights. However, a correlation coefficient of 0.769 between the utility values of the two instruments suggests that the main discordance is simply a difference in scale between the measures. It is also possible to map PROMIS-29 utility weights onto an EQ-5D-3L scale. EQ-5D-3L losses equal .1784 × (PROMIS-29 Losses) .7286 . The published estimates of the PROMIS-29 produce lower utility values than many other health instruments. Mapping the PROMIS-29 estimates to an EQ-5D-3L scale alleviates this issue and allows for a more straightforward comparison between the PROMIS-29 and other common health instruments.

  7. Measurement properties of the EQ-5D-5L compared to the EQ-5D-3L across eight patient groups

    DEFF Research Database (Denmark)

    Janssen, M F; Pickard, A Simon; Golicki, Dominik

    2012-01-01

    PURPOSE: The aim of this study was to assess the measurement properties of the 5-level classification system of the EQ-5D (5L), in comparison with the 3-level EQ-5D (3L). METHODS: Participants (n = 3,919) from six countries, including eight patient groups with chronic conditions (cardiovascular...... of the 3-level system which improves upon the measurement properties, reducing the ceiling while improving discriminatory power and establishing convergent and known-groups validity.......), redistribution properties, ceiling, discriminatory power, convergent validity, and known-groups validity. RESULTS: Missing values were on average 0.8 % for 5L and 1.3 % for 3L. In total, 2.9 % of responses were inconsistent between 5L and 3L. Redistribution from 3L to 5L using EQ dimension-specific rating scales...

  8. [Validity and reliability of the spanish EQ-5D-Y proxy version].

    Science.gov (United States)

    Gusi, N; Perez-Sousa, M A; Gozalo-Delgado, M; Olivares, P R

    2014-10-01

    A proxy version of the EQ-5D-Y, a questionnaire to evaluate the Health Related Quality of Life (HRQoL) in children and adolescents, has recently been developed. There are currently no data on the validity and reliability of this tool. The objective of this study was to analyze the validity and reliability of the EQ-5D-Y proxy version. A core set of self-report tools, including the Spanish version of the EQ-5D-Y were administered to a group of Spanish children and adolescents drawn from the general population. A similar core set of internationally standardized proxy tools, including the EQ-5D-Y proxy version were administered to their parents. Test-retest reliability was determined, and correlations with other generic measurements of HRQoL were calculated. Additionally, known group validity was examined by comparing groups with a priori expected differences in HRQoL. The agreement between the self-report and proxy version responses was also calculated. A total of 477 children and adolescents and their parents participated in the study. One week later, 158 participants completed the EQ-5D-Y/EQ-5D-Y proxy to facilitate reliability analysis. Agreement between the test-retest scores was higher than 88% for EQ-5D-Y self-report, and proxy version. Correlations with other health measurements showed similar convergent validity to that observed in the international EQ-5D-Y. Agreement between the self-report and proxy versions ranged from 72.9% to 97.1%. The results provide preliminary evidence of the reliability and validity of the EQ-5D-Y proxy version. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  9. German Value Set for the EQ-5D-5L.

    Science.gov (United States)

    Ludwig, Kristina; Graf von der Schulenburg, J-Matthias; Greiner, Wolfgang

    2018-06-01

    The objective of this study was to develop a value set for EQ-5D-5L based on the societal preferences of the German population. As the first country to do so, the study design used the improved EQ-5D-5L valuation protocol 2.0 developed by the EuroQol Group, including a feedback module as internal validation and a quality control process that was missing in the first wave of EQ-5D-5L valuation studies. A representative sample of the general German population (n = 1158) was interviewed using a composite time trade-off and a discrete choice experiment under close quality control. Econometric modeling was used to estimate values for all 3125 possible health states described by EQ-5D-5L. The value set was based on a hybrid model including all available information from the composite time trade-off and discrete choice experiment valuations without any exclusions due to data issues. The final German value set was constructed from a combination of a conditional logit model for the discrete choice experiment data and a censored at -1 Tobit model for the composite time trade-off data, correcting for heteroskedasticity. The value set had logically consistent parameter estimates (p German version of EQ-5D-5L representing the preferences of the German population. The study successfully employed for the first time worldwide the improved protocol 2.0. The value set enables the use of the EQ-5D-5L instrument in economic evaluations and in clinical studies.

  10. Intoxicação experimental por monensina em eqüinos

    Directory of Open Access Journals (Sweden)

    Bezerra Jr Pedro Soares

    2000-01-01

    Full Text Available Sete eqüinos foram tratados experimentalmente com monensina sódica. Dois desses animais receberem 3-4 kg/eqüino/dia de uma ração comercial sabidamente implicada em surtos naturais da intoxicação por monensina em eqüinos e que continha 180 ppm±20 da droga. Um eqüino recebeu uma única dose de 5 mg/kg e um outro recebeu 4 doses diárias de 1 mg/kg de monensina sódica originária de um premix. Esses quatro eqüinos morreram ou foram sacrificados in extremis, 3-8 dias após o início da administração da droga. Um quinto eqüino recebeu dose única de 5 mg/kg de monensina, ficou levemente doente e se recuperou. Dois eqüinos não desenvolveram sinais da intoxicação. Um desses eqüinos tinha recebido 40 doses diárias de 0,5 mg/kg de monensina e o outro recebeu 3 kg/dia de uma ração da mesma marca que a usada nas fazendas onde surtos de intoxicação por monensina foram detectados (mas de uma outra partida, mais tarde determinada como contendo menos de 5 ppm de monensina. O aparecimento dos sinais clínicos ocorreu de 2 a 5 dias após a administração da droga e a duração do quadro clínico variou de 24 a 76 horas. Os sinais clínicos incluíam taquicardia, arritmia, gemidos, incoordenação, sudorese, decúbito esternal, decúbito lateral, pedaleios e morte. Em cinco dos eqüinos intoxicados observaram-se marcadas elevações da atividade plasmática de creatina fosfoquinase e, em um eqüino, houve leve aumento da atividade plasmática de aspartato aminotransferase. Os principais achados de necropsia consistiram em áreas brancas ou amarelas, focais ou focalmente extensas e bilateralmente simétricas nos músculos esqueléticos. Essas lesões eram associadas a edema gelatinoso e translúcido das fáscias intermusculares. Quadríceps femoral, adutor, pectíneo, grácil, semi-membranáceo, supra-espinhal, subescapular, braquicefálico e quadríceps femoral estavam entre os músculos esqueléticos mais afetados. Os exames histol

  11. Development and validation of the alcohol Expectancy Questionnaire Short Form (EQ-SF).

    Science.gov (United States)

    Mezquita, Laura; Camacho, Laura; Suso-Ribera, Carlos; Ortet, Generós; Ibáñez, Manuel I

    2018-01-15

    Alcohol expectancies are proximal variables to alcohol use and misuse. In recent decades, different measures have been developed to assess this construct. One of the most frequently used and recommended instruments is the Expectancy Questionnaire (EQ; Leigh y Stacy, 1993). Our aim is to develop a short version of the EQ (EQ-SF) for suitable use in time-limited administrations. Two samples, adolescents (N = 514, 57.20% females) and adults (N = 548, 61.50% females), completed the EQ together with alcohol-use measures. Different item selection strategies were applied to select the 24 items. The EQ-SF structure was explored using confirmatory factor analysis, and measurement invariance was tested running a multi-group analysis comparing groups by sex and age. Reliability was tested using Cronbach's alpha and omega coefficients. Concurrent validity was investigated with regression analyses. The EQ-SF showed acceptable between-groups measurement invariance. Alphas and omegas ranged from .77 to .93. Positive expectancies predicted both alcohol use and alcohol-related problems. Negative expectancies predicted alcohol-related problems. Sex and age moderated these associations. Males with high positive alcohol expectancies showed higher alcohol consumption than females, while adults with high negative alcohol expectancies showed greater alcohol-related problems than adolescents. Different evidence on the validity and reliability of the EQ-SF suggest that it is a suitable instrument to assess alcohol expectancies in the Spanish population.

  12. Canadian valuation of EQ-5D health states: preliminary value set and considerations for future valuation studies.

    Directory of Open Access Journals (Sweden)

    Nick Bansback

    Full Text Available The EQ-5D is a preference based instrument which provides a description of a respondent's health status, and an empirically derived value for that health state often from a representative sample of the general population. It is commonly used to derive Quality Adjusted Life Year calculations (QALY in economic evaluations. However, values for health states have been found to differ between countries. The objective of this study was to develop a set of values for the EQ-5D health states for use in Canada.Values for 48 different EQ-5D health states were elicited using the Time Trade Off (TTO via a web survey in English. A random effect model was fitted to the data to estimate values for all 243 health states of the EQ-5D. Various model specifications were explored. Comparisons with EQ-5D values from the UK and US were made. Sensitivity analysis explored different transformations of values worse than dead, and exclusion criteria of subjects.The final model was estimated from the values of 1145 subjects with socio-demographics broadly representative of Canadian general population with the exception of Quebec. This yielded a good fit with observed TTO values, with an overall R2 of 0.403 and a mean absolute error of 0.044.A preference-weight algorithm for Canadian studies that include the EQ-5D is developed. The primary limitations regarded the representativeness of the final sample, given the language used (English only, the method of recruitment, and the difficulty in the task. Insights into potential issues for conducting valuation studies in countries as large and diverse as Canada are gained.

  13. LC-MS/MS suggests that hole hopping in cytochrome c peroxidase protects its heme from oxidative modification by excess H2O2.

    Science.gov (United States)

    Kathiresan, Meena; English, Ann M

    2017-02-01

    We recently reported that cytochrome c peroxidase (Ccp1) functions as a H 2 O 2 sensor protein when H 2 O 2 levels rise in respiring yeast. The availability of its reducing substrate, ferrocytochrome c (Cyc II ), determines whether Ccp1 acts as a H 2 O 2 sensor or peroxidase. For H 2 O 2 to serve as a signal it must modify its receptor so we employed high-performance LC-MS/MS to investigate in detail the oxidation of Ccp1 by 1, 5 and 10 M eq. of H 2 O 2 in the absence of Cyc II to prevent peroxidase activity. We observe strictly heme-mediated oxidation, implicating sequential cycles of binding and reduction of H 2 O 2 at Ccp1's heme. This results in the incorporation of ∼20 oxygen atoms predominantly at methionine and tryptophan residues. Extensive intramolecular dityrosine crosslinking involving neighboring residues was uncovered by LC-MS/MS sequencing of the crosslinked peptides. The proximal heme ligand, H175, is converted to oxo-histidine, which labilizes the heme but irreversible heme oxidation is avoided by hole hopping to the polypeptide until oxidation of the catalytic distal H52 in Ccp1 treated with 10 M eq. of H 2 O 2 shuts down heterolytic cleavage of H 2 O 2 at the heme. Mapping of the 24 oxidized residues in Ccp1 reveals that hole hopping from the heme is directed to three polypeptide zones rich in redox-active residues. This unprecedented analysis unveils the remarkable capacity of a polypeptide to direct hole hopping away from its active site, consistent with heme labilization being a key outcome of Ccp1-mediated H 2 O 2 signaling. LC-MS/MS identification of the oxidized residues also exposes the bias of electron paramagnetic resonance (EPR) detection toward transient radicals with low O 2 reactivity.

  14. Avaliação de solução concentrada de albumina eqüina na fluidoterapia em eqüinos com desidratação leve a moderada

    OpenAIRE

    Carla Bargi Belli

    2005-01-01

    A utilização de colóides é indicada em várias situações, mas nem sempre aplicável na clínica de eqüinos. O objetivo desse trabalho foi avaliar o uso de solução concentrada de albumina eqüina (diluída a 5%) durante fluidoterapia em eqüinos com desidratação leve a moderada, comparando-a com fluidoterapia apenas com solução fisiológica. Foram utilizados dois grupos de cinco eqüinos adultos, sem alterações clínicas. Cada animal passou pelo protocolo dos dois grupos experimentais (fluidoterapia ap...

  15. Validation of the EQ-5D in a general population sample in urban China.

    Science.gov (United States)

    Wang, Hong-Mei; Patrick, Donald L; Edwards, Todd C; Skalicky, Anne M; Zeng, Hai-Yan; Gu, Wen-Wen

    2012-02-01

    To evaluate the reliability and validity of the EQ-5D in a general population sample in urban China. Thousand and eight hundred respondents in 18 communities of Hangzhou, China were recruited by multi-stage stratified random sampling. Respondents self-administered a questionnaire including the EQ-5D, the SF-36, and demographic questions. Test-retest reliability at 2-week intervals was evaluated using Kappa coefficient, the intraclass correlation coefficient. The standard error of measurement (SEM) was used to indicate the absolute measurement error. Construct validity was established using convergent, discriminant, and known groups analyses. Complete data for all EQ-5D dimensions were available for 1,747 respondents (97%). Kappa values were from 0.35 to 1.0. The ICCs of test-retest reliability were 0.53 for the EQ-5D index score and 0.87 for the EQ VAS score. The SEM values were 0.13 (9.22% range) and 4.20 (4.20% range) for the EQ-5D index and EQ VAS scores, respectively. The Pearson's correlation coefficients between the EQ-5D and the SF-36 were stronger between comparable dimensions than those between less comparable dimensions, demonstrating convergent and discriminant evidence of construct validity. The Chinese EQ-5D distinguished well between known groups: respondents who reported poor general health and chronic diseases had worse HRQoL than those without. Older people, females, people widowed or divorced, and those with a lower socioeconomic status reported poorer HRQoL. Respondents reporting no problems on any EQ-5D dimension had better scores on the SF-36 summary scores than those reporting problems. The Chinese version of the EQ-5D demonstrated acceptable construct validity and fair to moderate levels of test-retest reliability in an urban general population in China.

  16. EQ3/6 data base - Ongoing development at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Delany, J.M.

    1986-01-01

    The EQ/6 Data Base has been revised and enhanced to meet the maintenance needs of a large continuously evolving data base. Within the last year a new data-base structure has been developed to manage the manipulation, basic data entry, import/export, retrieval and display features. The data management approach includes visual simplicity, on-line documentation, information management and controls to limit user error, ensure data protection and proper documentation of thermodynamic values and their sources

  17. Estimating an exchange rate between the EQ-5D-3L and ASCOT.

    Science.gov (United States)

    Stevens, Katherine; Brazier, John; Rowen, Donna

    2018-06-01

    The aim was to estimate an exchange rate between EQ-5D-3L and the Adult Social Care Outcome Tool (ASCOT) using preference-based mapping via common time trade-off (TTO) valuations. EQ-5D and ASCOT are useful for examining cost-effectiveness within the health and social care sectors, respectively, but there is a policy need to understand overall benefits and compare across sectors to assess relative value for money. Standard statistical mapping is unsuitable since it relies on conceptual overlap of the measures but EQ-5D and ASCOT have different conceptualisations of quality of life. We use a preference-based mapping approach to estimate the exchange rate using common TTO valuations for both measures. A sample of health states from each measure was valued using TTO by 200 members of the UK adult general population. Regression analyses are used to generate separate equations between EQ-5D-3L and ASCOT values using their original value set and TTO values elicited here. These are solved as simultaneous equations to estimate the relationship between EQ-5D-3L and ASCOT. The relationship for moving from ASCOT to EQ-5D-3L is a linear transformation with an intercept of -0.0488 and gradient of 0.978. This enables QALY gains generated by ASCOT and EQ-5D to be compared across different interventions. This paper estimated an exchange rate between ASCOT and EQ-5D-3L using a preference-based mapping approach that does not compromise the descriptive systems of the two measures. This contributes to the development of preference-based mapping through the use of TTO as the common metric used to estimate the exchange rate between measures.

  18. Interim report on modeling sorption with EQ3/6

    International Nuclear Information System (INIS)

    Viani, B.

    1988-01-01

    Reversible, equilibrium models of sorption to be incorporated into the EQ3/6 geochemical modeling package are summarized. Empirical sorption models as formulated in linear, Langmuir, and Freundlich isotherms will be developed as options to EQ3/6. This work will be done at LLNL. Options for modeling sorption using surface- complexation constructs (diffuse, constant capacitance, and triple-layer models) will also be developed. Development of the surface-complexation options will require part of the work be done under contract. 27 refs., 1 fig

  19. Preliminary findings of an investigation into the relationship between national culture and EQ-5D value sets.

    Science.gov (United States)

    Bailey, Henry; Kind, Paul

    2010-10-01

    Despite the growing importance of the EQ-5D descriptive system as a basis for the valuation of QALYs in cost-utility analysis, for most countries, there are no EQ-5D value sets. Researchers and policy makers wishing to use the EQ-5D descriptive system in a country for which there is no value set are advised to use one from a nearby or 'similar' population. Factors other than geographic proximity can affect the relative values of EQ-5D states. This study explores the links between national culture and EQ-5D value sets. Rank correlation analysis is used to explore relationships between the relative values of a set of EQ-5D states and dimensions of national culture. The latter are taken from Hofstede's framework which operationalizes national culture in five dimensions. For the data currently available (countries for which EQ-5D value sets and scores on dimensions of culture both exist), moderate and strong correlations were found between the culture dimension of power distance and individualism and the EQ-5D dimensions of pain/discomfort and anxiety/depression. Moderate correlations were also observed between the cultural dimension of masculinity and the EQ-5D dimensions of self care, usual activities and pain/discomfort. Uncertainty avoidance correlates with the EQ-5D dimension of anxiety/depression. The correlation patterns observed are generally consistent with a priori expectations based on the nature of the dimensions of culture and the EQ-5D model. This analysis demonstrates the potential of national culture in providing insight into the drivers of the relative values of EQ-5D dimensions for different countries and in informing decisions about which EQ-5D value sets to use in situations where one does not exist.

  20. BioPlex Display: An Interactive Suite for Large-Scale AP-MS Protein-Protein Interaction Data.

    Science.gov (United States)

    Schweppe, Devin K; Huttlin, Edward L; Harper, J Wade; Gygi, Steven P

    2018-01-05

    The development of large-scale data sets requires a new means to display and disseminate research studies to large audiences. Knowledge of protein-protein interaction (PPI) networks has become a principle interest of many groups within the field of proteomics. At the confluence of technologies, such as cross-linking mass spectrometry, yeast two-hybrid, protein cofractionation, and affinity purification mass spectrometry (AP-MS), detection of PPIs can uncover novel biological inferences at a high-throughput. Thus new platforms to provide community access to large data sets are necessary. To this end, we have developed a web application that enables exploration and dissemination of the growing BioPlex interaction network. BioPlex is a large-scale interactome data set based on AP-MS of baits from the human ORFeome. The latest BioPlex data set release (BioPlex 2.0) contains 56 553 interactions from 5891 AP-MS experiments. To improve community access to this vast compendium of interactions, we developed BioPlex Display, which integrates individual protein querying, access to empirical data, and on-the-fly annotation of networks within an easy-to-use and mobile web application. BioPlex Display enables rapid acquisition of data from BioPlex and development of hypotheses based on protein interactions.

  1. Disturbed mouse circadian rhythm before the Kobe EQ in 1995

    Science.gov (United States)

    Yokoi, Sayoko

    2013-04-01

    Legends of macro-anomalies before large earthquakes have been passed down for generations in Asia. Most of the statements on earthquake precursors are considered unreliable afterthoughts by traditional scientists. However, disturbed biological rhythms in mice were observed before the Kobe EQ in 1995 (Yokoi et al, 2003). The records of unusual mouse behavior before the earthquake were obtained to study biological clock at Institute for Protein Research, Osaka University. It is clarified that the disturbance was very rare phenomena statistically. Similar phenomenon was observed before the Wenchuan earthquake in 2008, too (Li et al, 2009). In the presentation, I will discuss the phenomena as one example of preseismic unusual animal behaviors.

  2. Validez convergente y discriminante del Inventario de Cociente Emocional (EQ-i

    Directory of Open Access Journals (Sweden)

    Evangelina Regner

    2008-01-01

    Full Text Available Desde la aparición del constructo de inteligencia emocional (Salovey & Mayer, 1990 el campo de las habilidades emocionales se ha ido ampliando notablemente, debido a la apa rición de diferentes conceptualizaciones, teorías e instrumentos de medición. Los desarrollos actuales se han centrado en el estudio de la validez de las pruebas utilizadas para medir la inteligencia emocional. El objetivo de la investigación que se informa fue estudiar la validez convergente y discriminante del Inventario de Cociente Emocional (EQ-i de Bar-On (1997a, 1997b en una muestra argentina de 100 personas adultas. Los instrumentos aplicados fueron: el EQ-i, el Inventario Re visado de Personalidad NEO (NEO PI-R de Costa y Mc Crae (1992 y la Prueba de Inteligencia o de Razonamiento Ver bal (RV de Bennett, Seashore y Wesman (1992. Para analizar los datos se realizaron correlaciones entre el EQ-i, el NEO PI-R y RV y regresiones múltiples por pasos sucesivos entre los factores de personalidad del NEO PI-R y las escalas de inteligencia emocional del EQ-i...

  3. The Predictability of Iranian EFL Teachers’ Emotional Quotient (EQ with Their Job Satisfaction

    Directory of Open Access Journals (Sweden)

    Pantea Khoshnoodfar

    2018-03-01

    Full Text Available As teacher education and teacher related issues are under the attention in the past decade in second language (L2 teaching /learning; this research investigated the predictability of Iranian EFL teachers’ emotional quotient (EQ with their job satisfaction. To this end, 90 EFL teachers at English language institutes in Tehran province were selected as the participants. The needed data was gathered by the use of two standardized questionnaires (filled by the participants: EQ and teacher job satisfaction questionnaires. First of all, the normality of the gathered data was checked through using SPSS version 23. Then, the Spearman coefficient of correlation was used to find whether there is any relationship between the participants’ EQ and job satisfaction.  The results proved the two variables had a statistically significant and positive correlation with each other. In the next step, the researchers opted for the multiple regression analysis to achieve the research objective. The present study was a quasi-Experimental including a cause and effect design. The predictor was the independent variable (EQ and the predicted one was the dependent variable (job satisfaction. The findings illustrated a statistically significant and positive predictability of Iranian EFL teachers’ EQ with their job satisfaction. The results of the present research would be useful for second language teacher education courses. It was proven that, since teachers’ EQ can control their job satisfaction, the findings of the present paper could be beneficial in teacher training issues and teacher education.

  4. Reliability and validity of the EQ-5D-3L for Kashin-Beck disease in China.

    Science.gov (United States)

    Fang, Hua; Farooq, Umer; Wang, Dimiao; Yu, Fangfang; Younus, Mohammad Imran; Guo, Xiong

    2016-01-01

    Kashin-Beck Disease (KBD) is an endemic osteoarthropathy in areas which extend from the North-East to the South-West of China. Most of the patients with KBD suffer multiple dysfunctions in major joints causing decreased health status. However because of their low education level and unique living habits, it is hard to find tools to measure the health-related quality of life (HRQOL). European quality of life (EQ-5D-3L) patient-reported instrument is widely used to measure HRQOL. This study aimed to establish the validity and reliability of the Chinese version of the EQ-5D-3L for evaluating HRQOL of KBD individuals in rural area. 368 individuals who were suffering from KBD were recruited through stratified multistage random sampling from Shaanxi province, China. The EQ-5D-3L and the WHOQOL-BREF were administrated in each individual by face to face interview. Test-retest reliability was assessed at 10-14 days intervals. The test-retest reliability was measured by calculating the Kappa coefficients for EQ-5D-3L five dimensions. For the EQ VAS, the intraclass correlation coefficient (ICC) was computed. Convergent and divergent analysis, construct validity was established using Spearman's rank correlation between the EQ-5D-3L and the WHOQOL-BREF. Known groups' validity was examined by comparing groups with a priori expected differences in health-related quality of life (HRQOL). For 362 individuals (98%), comprehensive data of all the EQ-5D-3L dimensions were available. Kappa values of the EQ-5D-3L five items ranged from 0.324 to 0.554. ICC of the EQ VAS was 0.497. For convergent validity, the three items (self-care, usual activity, and mobility) of EQ-5D-3L, index scores, and VAS showed moderate correlations with the physical health domain of the WHOQOL-BREF (r absolute value ranged from 0.339 to 0.475). For divergent validity, the 5 items of EQ-5D-3L showed weak or no correlations with environment and social relationship domains of WHOQOL-BREF. The Chinese EQ-5D-3L

  5. EQ-5D-3L as a health measure of Brazilian adult population.

    Science.gov (United States)

    Menezes, Renata de Miranda; Andrade, Mônica Viegas; Noronha, Kenya Valéria Micaela de Souza; Kind, Paul

    2015-11-01

    This study explores the use of EQ-5D-3L as a measure of population health status in a Brazilian region with significant socioeconomic, demographic, and epidemiological heterogeneity. Data came from a study of 3363 literate individuals aged between 18 and 64 years living in urban areas of the state of Minas Gerais. Descriptive analysis and logistic and OLS regression models were performed to analyze the relationship between EQ-5D-3L (descriptive system and EQ VAS) and other health (self-assessed health status and 8 self-reported diagnosed chronic diseases), socioeconomic (educational level and economic class), and demographic (gender and age) measures. Additionally, a grade of membership (GoM) analysis was performed to identify multidimensional health profiles. A total of 76 health statuses were identified in the Brazilian population. The most prevalent one is full health (44 % of the sample). Elderly people, women, and individuals with poor health and lower socioeconomic conditions generally report more health problems in the EQ-5D-3L dimensions. The GoM analysis demonstrated that health status of older individuals is associated with the socioeconomic condition. Arthritis exhibited the strongest association with the EQ-5D-3L instrument. The results indicate that EQ-5D-3L is a good measure of health status for the Brazilian population. The instrument has a good discriminatory capacity in terms of demographic, socioeconomic, and health measures. The high prevalence of individuals with full health may indicate the presence of ceiling effect. However, this prevalence is smaller than that in other countries.

  6. Anchoring Vignettes in EQ-5D-5L Questionnaire: Validation of a New Instrument.

    Science.gov (United States)

    Azzolina, Danila; Minto, Clara; Boschetto, Stefania; Martinato, Matteo; Bauce, Barbara; Iliceto, Sabino; Gregori, Dario

    2017-01-01

    Health Related Quality of Life (HRQoL) is an indicator of patient's physical, psychological and social life. HRQoL is influenced by experience, beliefs, perceptions and expectations, and measures subjective perspective of the patient himself. EQ-5D-5L and SF-12 questionnaires are validated instruments useful to measure HRQoL, increasingly administered in electronic formats. The main purpose is to evaluate the feasibility of anchoring vignettes for the EQ-5D-5L questionnaire, with the aim to improve intergroup comparability of responses among different subjects. A comparison with SF-12 questionnaire is carried out. This is a cross-sectional study conducted at the ambulatories of cardiology of the University Hospital of Padova, in Italy. Thirty-eight subjects with a diagnosis of cardiovascular disease or at risk of cardiovascular disease were enrolled. A factorial analysis has been performed to assess the convergent validity of EQ-5D-5L questionnaire compared to Sf-12. Moreover, a compound Hierarchical Ordered Probit (Chopit) model has been estimated to evaluate if the questionnaire form affects the subjective evaluation process in order to compare EQ-5D-5L with and without vignettes. Correlation and factor analysis demonstrate that EQ_5D questionnaire is coherent with SF-12 in paper format. Chopit model estimation shows that questionnaire format does not affect the subjective question interpretation. Moreover, in a parametric model including vignettes, education attainment, disease severity, and gender are predictors of HRQoL status. The EQ-5D including vignettes in electronic format seems to be a valid tool to measure HRQoL as compared to EQ-5D without vignettes in paper format and to SF-12 questionnaire.

  7. Validity and responsiveness of the EQ-5D in assessing and valuing health status in patients with anxiety disorders

    Directory of Open Access Journals (Sweden)

    Heinrich Sven

    2010-05-01

    Full Text Available Abstract Background The EQ-5D is a generic questionnaire which generates a health profile as well as index scores for health-related quality of life that may be used in cost-utility analysis. Aims of the study To examine validity and responsiveness of the EQ-5D in patients with anxiety disorders. Methods 389 patients with anxiety disorders completed the EQ-5D at baseline and 6-month follow-up. Subjective measures of quality of life (WHOQOL-BREF and psychopathology (BAI, BDI-II, BSQ, ACQ, MI were used for comparison. Validity was analyzed by assessing associations between EQ-5D scores and related other scores. Responsiveness was analyzed by calculating effect sizes of differences in scores between baseline and follow-up for 3 groups indicating more, constant or less anxiety. Meaningful difference scores for shifting to less or more anxiety were derived by means of regression analysis. Results 88.4% of respondents reported problems in at least one of the EQ-5D dimension at baseline; the mean EQ VAS score was 63.8. The EQ-5D dimension most consistently associated with the measures used for comparison was 'anxiety/depression'. EQ VAS and EQ-5D index scores were highly correlated (|r|>0.5 with scores of the WHOQOL-BREF dimensions 'physical', 'mental' and 'overall' as well as BAI and BDI-II. The EQ-5D index tended to be the most responsive score. Standardized meaningful difference scores were not significantly different between EQ VAS, EQ-5D index and measures used for comparison. Conclusions The EQ-5D seems to be reasonably valid and moderately responsive in patients with anxiety disorders. The EQ-5D index may be suitable for calculating QALYs in economic evaluation of health care interventions for patients with anxiety disorders. Trial registration Current Controlled Trials ISRCTN15716049

  8. Validity, responsiveness, and minimal clinically important difference of EQ-5D-5L in stroke patients undergoing rehabilitation.

    Science.gov (United States)

    Chen, Poyu; Lin, Keh-Chung; Liing, Rong-Jiuan; Wu, Ching-Yi; Chen, Chia-Ling; Chang, Ku-Chou

    2016-06-01

    To examine the criterion validity, responsiveness, and minimal clinically important difference (MCID) of the EuroQoL 5-Dimensions Questionnaire (EQ-5D-5L) and visual analog scale (EQ-VAS) in people receiving rehabilitation after stroke. The EQ-5D-5L, along with four criterion measures-the Medical Research Council scales for muscle strength, the Fugl-Meyer assessment, the functional independence measure, and the Stroke Impact Scale-was administered to 65 patients with stroke before and after 3- to 4-week therapy. Criterion validity was estimated using the Spearman correlation coefficient. Responsiveness was analyzed by the effect size, standardized response mean (SRM), and criterion responsiveness. The MCID was determined by anchor-based and distribution-based approaches. The percentage of patients exceeding the MCID was also reported. Concurrent validity of the EQ-Index was better compared with the EQ-VAS. The EQ-Index has better power for predicting the rehabilitation outcome in the activities of daily living than other motor-related outcome measures. The EQ-Index was moderately responsive to change (SRM = 0.63), whereas the EQ-VAS was only mildly responsive to change. The MCID estimation of the EQ-Index (the percentage of patients exceeding the MCID) was 0.10 (33.8 %) and 0.10 (33.8 %) based on the anchor-based and distribution-based approaches, respectively, and the estimation of EQ-VAS was 8.61 (41.5 %) and 10.82 (32.3 %). The EQ-Index has shown reasonable concurrent validity, limited predictive validity, and acceptable responsiveness for detecting the health-related quality of life in stroke patients undergoing rehabilitation, but not for EQ-VAS. Future research considering different recovery stages after stroke is warranted to validate these estimations.

  9. Is there a link between the volume of physical exercise and emotional intelligence (EQ?

    Directory of Open Access Journals (Sweden)

    Gáspár Zoltán

    2017-03-01

    Full Text Available Emotional intelligence (EQ was linked to sport participation. We report two studies in which we tested the link between exercise volume, defined as weekly hours of exercise, and EQ. Volunteers (n = 64 and n = 84 completed the Wong and Law Emotional Intelligence Scale. In Study I, significant correlations between exercise volume and use- and regulation-of-emotions prompted us to use a posteriori grouping into high- and low exercise-volume groups. The former exhibited better use-of-emotions than the latter (p = .007, d = .87. In Study II, using a priori grouping, we replicated the finding from Study I (p = .001, d = .78, and the groups also differed in “self-emotions appraisal” (p = .05, d = .44 and total EQ (p = .017, d = .54. Since the items measuring the use-of-emotions involve motivational aspects of the EQ, we posit that this dimension is “naturally” linked to exercise volume. Our findings also suggest that self-emotions appraisal and the overall EQ are linked to greater volumes of exercise. These results should provide an incentive for longitudinal studies in this area.

  10. Social tension as precursor of large damaging earthquake: legend or reality?

    Science.gov (United States)

    Molchanov, O.

    2008-11-01

    Using case study of earthquake (EQ) activity and war conflicts in Caucasus during 1975 2002 time interval and correlation analysis of global distribution of damaging EQs and war-related social tension during 1901 2005 period we conclude: There is a statistically reliable increase of social tension several years (or several months in case study) before damaging EQs, There is evident decrease of social tension several years after damaging EQs, probably due to society consolidation, Preseismic effect is absent for the large EQs in unpopulated areas, There is some factual background for legendary belief in Almighty retribution for social abnormal behavior.

  11. CO{sub 2}-EQ emissions of forest chip production in Finland in 2020

    Energy Technology Data Exchange (ETDEWEB)

    Kariniemi, Arto; Kaerhae, Kalle (Metsaeteho Oy, Helsinki (Finland)), e-mail: arto.kariniemi@metsateho.fi

    2010-07-15

    The research carried out by Metsaeteho Oy calculated what would be the total fuel consumption and CO{sub 2}-eq emissions of forest chip production if the use of forest chips is 24 TWh in 2020 in Finland in accordance with the target set of Long-term Climate and Energy Strategy. CO{sub 2}-eq emissions were determined with Metsaeteho Oy's updated Emissions Calculation Model. If the production and consumption of forest chips in Finland are 24 TWh in 2020, then the total CO{sub 2}-eq emissions would be around 230,000 tonnes. The volume of diesel consumption was 73 million litres and petrol 1.7 million litres. Electric rail transportation and chipping at the mill site consumed 17 GWh of electricity. The supply chain with the lowest CO{sub 2}-eq emissions was logging residues comminuted at plant. Conversely, the highest CO{sub 2}-eq emissions came from stump wood when operating with terminal comminuting. Less than 3% of the energy content was consumed during the forest chip production. Energy input/output ratio in the total volume was 0.026 MWh/MWh which varied from 0.019 to 0.038 between the supply systems researched. Hence, forest chip production gave a net of some 97% of the energy content delivered at the plant

  12. Calculation of chemical equilibrium between aqueous solution and minerals: the EQ3/6 software package

    International Nuclear Information System (INIS)

    Wolery, T.J.

    1979-01-01

    The newly developed EQ/36 software package computes equilibrium models of aqueous geochemical systems. The package contains two principal programs: EQ3 performs distribution-of-species calculations for natural water compositions; EQ6 uses the results of EQ3 to predict the consequences of heating and cooling aqueous solutions and of irreversible reaction in rock--water systems. The programs are valuable for studying such phenomena as the formation of ore bodies, scaling and plugging in geothermal development, and the long-term disposal of nuclear waste. EQ3 and EQ6 are compared with such well-known geochemical codes as SOLMNEQ, WATEQ, REDEQL, MINEQL, and PATHI. The data base allows calculations in the temperature interval 0 to 350 0 C, at either 1 atm-steam saturation pressures or a constant 500 bars. The activity coefficient approximations for aqueous solutes limit modeling to solutions of ionic strength less than about one molal. The mathematical derivations and numerical techniques used in EQ6 are presented in detail. The program uses the Newton--Raphson method to solve the governing equations of chemical equilibrium for a system of specified elemental composition at fixed temperature and pressure. Convergence is aided by optimizing starting estimates and by under-relaxation techniques. The minerals present in the stable phase assemblage are found by several empirical methods. Reaction path models may be generated by using this approach in conjunction with finite differences. This method is analogous to applying high-order predictor--corrector methods to integrate a corresponding set of ordinary differential equations, but avoids propagation of error (drift). 8 figures, 9 tables

  13. Application and measurement properties of EQ-5D to measure quality of life in patients with upper extremity orthopaedic disorders: a systematic literature review.

    Science.gov (United States)

    Grobet, Cécile; Marks, Miriam; Tecklenburg, Linda; Audigé, Laurent

    2018-04-13

    The EuroQol-5 Dimension (EQ-5D) is the most widely used generic instrument to measure quality of life (QoL), yet its application in upper extremity orthopaedics as well as its measurement properties remain largely undefined. We implemented a systematic literature review to provide an overview of the application of EQ-5D in patients with upper extremity disorders and analyse its measurement properties. We searched Medline, EMBASE, Cochrane and Scopus databases for clinical studies including orthopaedic patients with surgical interventions of the upper extremity who completed the EQ-5D. For all included studies, the use of EQ-5D and quantitative QoL data were described. Validation studies of EQ-5D were assessed according to COSMIN guidelines and standard measurement properties were examined. Twenty-three studies were included in the review, 19 of which investigated patients with an intervention carried out at the shoulder region. In 15 studies, EQ-5D assessed QoL as the primary outcome. Utility index scores in non-trauma patients generally improved postoperatively, whereas trauma patients did not regain their recalled pre-injury QoL levels. EQ-5D measurement properties were reported in three articles on proximal humerus fractures and carpal tunnel syndrome. Positive ratings were seen for construct validity (Spearman correlation coefficient ≥ 0.70 with the Short Form (SF)-12 or SF-6D health surveys) and reliability (intraclass correlation coefficient ≥ 0.77) with intermediate responsiveness (standardised response means: 0.5-0.9). However, ceiling effects were identified with 16-48% of the patients scoring the maximum QoL. The methodological quality of the three articles varied from fair to good. For surgical interventions of the upper extremity, EQ-5D was mostly applied to assess QoL as a primary outcome in patients with shoulder disorders. Investigations of the measurement properties were rare, but indicate good reliability and validity as well as

  14. The Earth's revolution, Moon phase, Syzygy astronomy events, their effect in disturbances of the Earth's geomagnetic field, and the ``Magnetic Storm Double Time Method'' for predicting the occurrence time, magnitude and epicenter location of earthquakes

    Science.gov (United States)

    Chen, I. W.

    2003-04-01

    An increasing number of geomagnetic observation stations were established and operated in China since 1966 to the 1980s (and until present), effectively covering a large area of the nation. Close relativity between magnetic storms and earthquakes, as well as close relativity between the regional differences of magnetic disturbance recorded by these stations and the epicenter location of earthquakes, was discovered and observed by Tie-zheng Zhang during1966 - 1969. On such basis during 1969/1970, Zhang developed the “Magnetic Storm Double Time Method” for predicting the occurrence time, magnitude and epicenter location of EQs. By this method,.Zhang successfully predicted the Yunnan Tonghai Ms7.7 EQ Jan. 5, 1970 (occurrence date only), the Bohai ML5.2 EQ, Feb. 12, 1970 and other EQs, including the Haicheng Ms7.3 EQ Feb. 4, 1975, and the Tangshan Ms7.8 EQ July 28, 1976. On the basis of this method, Z.P. Shen developed the “Geomagnetic Deflection Angle Double Time Method” in 1970, and later developed the “Magnetic Storm - Moon Phase Double Time Method” in 1990s. With this method, Shen is able to predict the occurrence dates of most of the strongest EQs Ms37.5 on the Earth since 1991. Zhang also discovered that strong EQs often correspond with a number of sets of magnetic storms. Z.Q. Ren discovered close relativity exists between Syzygy astronomy events and such sets of magnetic storm as well as the occurrence dates of strong EQs. Computerized calculation of historical magnetic storm and EQ data proves the effectiveness of this method. Over 3,000 days of geomagnetic isoline images are computer processed by the Author from over 400,000 geomagnetic field data obtained by Zhang from over 100 geomagnetic observation stations during 1966 - 1984. Clear relativity is shown between the Earth’s revolution, Moon phases, Syzygy astronomy events related to the Earth, and their disturbance effect on the Earth’s geomagnetic field and the occurrence of EQs.

  15. The BarOn Emotional Quotient Inventory (EQ-i): Development and psychometric adaptation in Bahasa Indonesia

    NARCIS (Netherlands)

    Dewi, Z.L.; Halim, M.S.; Derksen, J.J.L.

    2015-01-01

    The BarOn Emotional Quotient Inventory (EQ-i ; BarOn, 2004) was created to assess emotional intelligence (EI). In our research project we produced the Indonesian version. The EQ-i was translated from English into Bahasa Indonesia and back-translated into English. Test-retest reliabilities and

  16. Comparison of howRU and EQ-5D measures of health-related quality of life in an outpatient clinic

    Directory of Open Access Journals (Sweden)

    Tim Benson

    2013-11-01

    Full Text Available This paper reports on a head-to-head study of howRU and EQ-5D on patients with cardiovascular disease. howRU is a short generic measure of health-related quality of life comprising 39 words, designed for routine use, which we compare with EQ-5D (230 words. Patients attending a clinic completed both instruments. Completed data were available for 116 patients, 51% female, mean age 56 and SD 20. howRU is shorter, has better readability statistics, a higher completion rate, a wider range of states used and a smaller ceiling effect than EQ-5D. The correlations of howRU with EQ-5D are similar to those of EQ-5D with other validated instruments.

  17. Estimating EQ-5D values from the Oswestry Disability Index and numeric rating scales for back and leg pain.

    Science.gov (United States)

    Carreon, Leah Y; Bratcher, Kelly R; Das, Nandita; Nienhuis, Jacob B; Glassman, Steven D

    2014-04-15

    Cross-sectional cohort. The purpose of this study is to determine whether the EuroQOL-5D (EQ-5D) can be derived from commonly available low back disease-specific health-related quality of life measures. The Oswestry Disability Index (ODI) and numeric rating scales (0-10) for back pain (BP) and leg pain (LP) are widely used disease-specific measures in patients with lumbar degenerative disorders. Increasingly, the EQ-5D is being used as a measure of utility due to ease of administration and scoring. The EQ-5D, ODI, BP, and LP were prospectively collected in 14,544 patients seen in clinic for lumbar degenerative disorders. Pearson correlation coefficients for paired observations from multiple time points between ODI, BP, LP, and EQ-5D were determined. Regression modeling was done to compute the EQ-5D score from the ODI, BP, and LP. The mean age was 53.3 ± 16.4 years and 41% were male. Correlations between the EQ-5D and the ODI, BP, and LP were statistically significant (P < 0.0001) with correlation coefficients of -0.77, -0.50, and -0.57, respectively. The regression equation: [0.97711 + (-0.00687 × ODI) + (-0.01488 × LP) + (-0.01008 × BP)] to predict EQ-5D, had an R2 of 0.61 and a root mean square error of 0.149. The model using ODI alone had an R2 of 0.57 and a root mean square error of 0.156. The model using the individual ODI items had an R2 of 0.64 and a root mean square error of 0.143. The correlation coefficient between the observed and estimated EQ-5D score was 0.78. There was no statistically significant difference between the actual EQ-5D (0.553 ± 0.238) and the estimated EQ-5D score (0.553 ± 0.186) using the ODI, BP, and LP regression model. However, rounding off the coefficients to less than 5 decimal places produced less accurate results. Unlike previous studies showing a robust relationship between low back-specific measures and the Short Form-6D, a similar relationship was not seen between the ODI, BP, LP, and the EQ-5D. Thus, the EQ-5D cannot be

  18. Equilíbrio ácido-base e hidroeletrolítico em eqüinos com cólica

    OpenAIRE

    Di Filippo,Paula Alessandra; Santana,Aureo Evangelista; Pereira,Gener Tadeu

    2008-01-01

    Foram utilizados setenta eqüinos distribuídos em três grupos experimentais, G1 (vinte eqüinos hígidos), G2 (vinte e cinco eqüinos com cólica, os quais passaram por tratamento clínico ou cirúrgico e sobreviveram) e G3 (vinte e cinco eqüinos com cólica, os quais passaram por tratamento clínico ou cirúrgico e foram a óbito ou foram sacrificados). Amostras de sangue foram obtidas em dez diferentes momentos, mediante punção da jugular, para estudo do equilíbrio ácido-base e hidroeletrolítico. Os e...

  19. Mieloencefalite protozoária eqüina (Relato de caso.

    Directory of Open Access Journals (Sweden)

    R. C. Gonçalves

    2005-03-01

    Full Text Available RESUMO :O objetivo deste trabalho foi relatar um caso de mieloencefalite protozoária eqüina no Estado de São Paulo, Brasil. O diagnóstico se baseou nos sinais clínicos, no resultado positivo para anticorpos contra Sarcocystis neurona no soro e no líquor pela técnica de Western blot. Palavras chave: Mieloencefalite, Sarcocystis neurona, eqüinos. SUMMARY: The purpose of this work was to present a case of equine protozoal myeloencephalitis (EPM in the State of São Paulo, Brazil. The diagnosis was based on the clinical sings, the positive results of the serum and cerebrospinal fluid analysis (Western blot for antibodies against Sarcocystis neurona. Keywords: Myeloencephalitis, Sarcocystis neurona,

  20. Quality of life profile of general Vietnamese population using EQ-5D-5L.

    Science.gov (United States)

    Nguyen, Long Hoang; Tran, Bach Xuan; Hoang Le, Quynh Ngoc; Tran, Tung Thanh; Latkin, Carl A

    2017-10-11

    Health-related quality of life (HRQOL) is a vital benchmark to assess the effects of health interventions and policies. Measuring HRQOL of the general population is essential to establish a reference for health outcomes evaluations. However, evidence on HRQOL of general populations in low and middle income countries is very limited. This study aimed to measure HRQOL of the Vietnamese population by using the EuroQol-5 dimensions-5 levels (EQ-5D-5L) instrument and determine its associated factors. A cross-sectional study was performed in Hanoi with 1571 residences in Hanoi, the capital city of Vietnam. EQ-5D-5L and EQ- visual analogue scale (EQ-VAS) were used to assess HRQOL. Potential covariates included socio-demographic characteristics, having acute symptoms in the last four weeks, chronic diseases in the last three months, having multiple health issues, and health service utilisation in the last twelve months. A generalized linear model was employed to identify the association between HRQOL and covariates. Overall, the mean EQ-5D utility index was 0.91 (SD = 0.15), and the mean EQ-VAS score was 87.4 (SD = 14.3). The highest proportion of respondents reporting any problems was in Usual activities (24.3%), followed by Anxiety/Depression (15.2%) and Pain/Discomfort (10.0%), while the lowest percentage was in Self-care (2.5%). Lower HRQOL composite scores were related to unemployment, lower income, higher education, living in urban areas, having chronic diseases, having multiple health issues and using health service. For any health problem self-reported by respondents, the health utility reduced by 0.02 (respiratory diseases) to 0.15 (musculoskeletal diseases). Health utility of the general population and reductions for self-reported health problems in this study are useful for future population health evaluations and comparisons. It also informs the development of interventions to reduce health problems of the general population.

  1. Testing mapping algorithms of the cancer-specific EORTC QLQ-C30 onto EQ-5D in malignant mesothelioma.

    Science.gov (United States)

    Arnold, David T; Rowen, Donna; Versteegh, Matthijs M; Morley, Anna; Hooper, Clare E; Maskell, Nicholas A

    2015-01-23

    In order to estimate utilities for cancer studies where the EQ-5D was not used, the EORTC QLQ-C30 can be used to estimate EQ-5D using existing mapping algorithms. Several mapping algorithms exist for this transformation, however, algorithms tend to lose accuracy in patients in poor health states. The aim of this study was to test all existing mapping algorithms of QLQ-C30 onto EQ-5D, in a dataset of patients with malignant pleural mesothelioma, an invariably fatal malignancy where no previous mapping estimation has been published. Health related quality of life (HRQoL) data where both the EQ-5D and QLQ-C30 were used simultaneously was obtained from the UK-based prospective observational SWAMP (South West Area Mesothelioma and Pemetrexed) trial. In the original trial 73 patients with pleural mesothelioma were offered palliative chemotherapy and their HRQoL was assessed across five time points. This data was used to test the nine available mapping algorithms found in the literature, comparing predicted against observed EQ-5D values. The ability of algorithms to predict the mean, minimise error and detect clinically significant differences was assessed. The dataset had a total of 250 observations across 5 timepoints. The linear regression mapping algorithms tested generally performed poorly, over-estimating the predicted compared to observed EQ-5D values, especially when observed EQ-5D was below 0.5. The best performing algorithm used a response mapping method and predicted the mean EQ-5D with accuracy with an average root mean squared error of 0.17 (Standard Deviation; 0.22). This algorithm reliably discriminated between clinically distinct subgroups seen in the primary dataset. This study tested mapping algorithms in a population with poor health states, where they have been previously shown to perform poorly. Further research into EQ-5D estimation should be directed at response mapping methods given its superior performance in this study.

  2. Extension of the EQ3/6 computer codes to geochemical modeling of brines

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, K.J.; Wolery, T.J.

    1984-10-23

    Recent modifications to the EQ3/6 geochemical modeling software package provide for the use of Pitzer's equations to calculate the activity coefficients of aqueous species and the activity of water. These changes extend the range of solute concentrations over which the codes can be used to dependably calculate equilibria in geochemical systems, and permit the inclusion of ion pairs, complexes, and undissociated acids and bases as explicit component species in the Pitzer model. Comparisons of calculations made by the EQ3NR and EQ6 compuer codes with experimental data confirm that the modifications not only allow the codes to accurately evaluate activity coefficients in concentrated solutions, but also permit prediction of solubility limits of evaporite minerals in brines at 25/sup 0/C and elevated temperatures. Calculations for a few salts can be made at temperatures up to approx. 300/sup 0/C, but the temperature range for most electrolytes is constrained by the availability of requisite data to values less than or equal to 100/sup 0/C. The implementation of Pitzer's equations in EQ3/6 allows application of these codes to problems involving calculation of geochemical equilibria in brines; such as evaluation of the chemical environment which might be anticipated for nuclear waste canisters located in a salt repository. 26 references, 3 figures, 1 table.

  3. Examining the incremental impact of long-standing health conditions on subjective well-being alongside the EQ-5D.

    Science.gov (United States)

    Wu, Mengjun; Brazier, John; Relton, Clare; Cooper, Cindy; Smith, Christine; Blackburn, Joanna

    2014-04-29

    Generic preference-based measures such as the EQ-5D and SF-6D have been criticised for being narrowly focused on a sub-set of dimensions of health. Our study aims to explore whether long-standing health conditions have an incremental impact on subjective well-being alongside the EQ-5D. Using data from the South Yorkshire Cohort study (N = 13,591) collected between 2010 and 2012 on the EQ-5D, long-standing health conditions (self-reported), and subjective well-being measure--life satisfaction using a response scale from 0 (completely dissatisfied) to 10 (completely satisfied), we employed generalised logit regression models. We assessed the impact of EQ-5D and long-standing health conditions together on life satisfaction by examining the size and significance of their estimated odds ratios. The EQ-5D had a significant association with life satisfaction, in which anxiety/depression and then self-care had the largest weights. Some long-standing health conditions were significant in some models, but most did not have an independent impact on life satisfaction. Overall, none of the health conditions had a consistent impact on life satisfaction alongside the EQ-5D. Out study suggests that the impact of long-standing health conditions on life satisfaction is adequately captured by the EQ-5D, although the findings are limited by reliance on self-reported conditions and a single item life satisfaction measure.

  4. The impact of a revised EQ-5D population scoring on preference-based utility scores in an inflammatory arthritis cohort.

    LENUS (Irish Health Repository)

    Adams, Roisin

    2012-02-01

    BACKGROUND AND OBJECTIVE: It is well established that there are problems with the EQ-5D. This is due to the original scoring methods used and how negative time trade-off (TTO) values were treated. A revised scoring method has been published. This article applies this to an inflammatory arthritis cohort. The objective is to examine the impact of a revised scoring system for the EQ-5D (UK) TTO on the utility estimates and in the case of rheumatoid arthritis, to explore the impact of using different utility metrics on the incremental cost-effectiveness ratio (ICER) results of an economic model. METHODS: A total of 504 patients with inflammatory arthritis were rescored using revised EQ-5D scoring, which uses an episodic random utility model to deal with negative TTO values. Differences in utility scores were compared and the new mapping coefficients were obtained. These were then used in an economic model to examine the impact on the ICER. RESULTS: In rheumatoid arthritis, the overall change is less for the revised EQ-5D scoring than with the original EQ-5D (TTO) but greater than the SF-6D: EQ-5D UK -0.22 (95% confidence interval [CI] -0.30 to -0.15), revised EQ-5D UK -0.16 (95% CI -0.21 to -0.10) and SF-6D -0.08 (95% CI -0.11 to -0.05). A similar trend is seen in the psoriatic arthritis group. The economic model produced different ICERs, when different utility measures were used; EQ-5D (TTO) euro42,402, SF-6D euro111,788, and revised EQ-5D (TTO) euro57,747. CONCLUSION: In the context of inflammatory arthritis, this article demonstrates that a revised scoring for EQ-5D may have a significant impact on utility estimates and on the output of the economic model.

  5. Does the EQ-5D measure quality of life in schizophrenia?

    DEFF Research Database (Denmark)

    Halling Hastrup, Lene; Nordentoft, Merete; Hjorthoej, Carsten

    2011-01-01

    Most health economic evaluations in mental care include outcome measures aimed at specific aspects of health, like symptom improvement, functional improvement and quality of life instead of generic preference based outcome measures. The health economic guidelines (NICE) recommend to include...... a generic preference based outcome measure, like EQ-5D, in health economic evaluations in order to allow for comparisons of health related quality of life of patient groups across different diseases, providing information particular useful to support health policy decisions and cost-effectiveness analysis...... in mental health, but only few studies have addressed the correlation between the EQ-5D and a condition-specific quality of life measure in mental health....

  6. Energy efficiency and CO{sub 2} -eq emissions of forest chip supply chains in Finland 2020

    Energy Technology Data Exchange (ETDEWEB)

    Kariniemi, A.; Kaerhae, K. (Metsaeteho Oy, Helsinki (Finland)), Email: arto.kariniemi@metsateho.fi, Email: kalle.karha@metsateho.fi

    2009-07-01

    The research carried out by Metsaeteho Oy calculated what would be the total fuel consumption and CO{sub 2}-eq emissions of forest chip production if the use of forest chips is 24 TWhin 2020 in Finland in accordance with the target set of Long-term Climate and Energy Strategy. CO{sub 2}-eq emissions were determined with Metsaeteho OY's updated Emissions Calculation Model. If the production and consumption of forest chips in Finland are 24 TWh in 2020, then the total CO{sub 2}-eq emissions would be around 245000 tonnes. The volume of diesel consumption was 79 million litres and petrol 1,5 millions litres. Electric rail transportation and chipping at the mill site consumed 15 GWh of electricity. The supply chain with the lowest CO{sub 2}-eq emissions was logging residues comminuted at plant. Conversely, the highest CO{sub 2}-eq emissions came from stump wood when operating with terminal comminuting. Some 3% of the energy content was consumed during the forest chip production. Energy input/output ratio in the total volume was 0.030 MWh/MWh which varied from 0.022 to 0.044 between the supply systems researched. Hence, forest chip production gave a net of some 97% of the energy content delivered at the plant. (orig.)

  7. Mapping MOS-HIV to HUI3 and EQ-5D-3L in Patients With HIV

    Directory of Open Access Journals (Sweden)

    Vilija R. Joyce MS

    2017-07-01

    Full Text Available Objectives: The Medical Outcomes Study HIV Health Survey (MOS-HIV is frequently used in HIV clinical trials; however, scores generated from the MOS-HIV are not suited for cost-effectiveness analyses as they do not assign utility values to health states. Our objective was to estimate and externally validate several mapping algorithms to predict Health Utilities Index Mark 3 (HUI3 and EQ-5D-3L utility values from the MOS-HIV. Methods: We developed and validated mapping algorithms using data from two HIV clinical trials. Data from the first trial (n = 367 formed the estimation data set for the HUI3 (4,610 observations and EQ-5D-3L (4,662 observations mapping algorithms; data from the second trial (n = 168 formed the HUI3 (1,135 observations and EQ-5D-3L (1,152 observations external validation data set. We compared ordinary least squares (OLS models of increasing complexity with the more flexible two-part, beta regression, and finite mixture models. We assessed model performance using mean absolute error (MAE and mean squared error (MSE. Results: The OLS model that used MOS-HIV dimension scores along with squared terms gave the best HUI3 predictions (mean observed 0.84; mean predicted 0.80; MAE 0.0961; the finite mixture model gave the best EQ-5D-3L predictions (mean observed 0.90; mean predicted 0.88; MAE 0.0567. All models produced higher prediction errors at the lower end of the HUI3 and EQ-5D-3L score ranges (<0.40. Conclusions: The proposed mapping algorithms can be used to predict HUI3 and EQ-5D-3L utility values from the MOS-HIV, although greater error may pose a problem in samples where a substantial proportion of patients are in poor health. These algorithms may be useful for estimating utility values from the MOS-HIV for cost-effectiveness studies when HUI3 or EQ-5D-3L data are not available.

  8. Multi-Objective Optimization of Building Energy Design to Reconcile Collective and Private Perspectives: CO2-eq vs. Discounted Payback Time

    Directory of Open Access Journals (Sweden)

    Mohamed Hamdy

    2017-07-01

    Full Text Available Building energy design is a multi-objective optimization problem where collective and private perspectives conflict each other. For instance, whereas the collectivity pursues the minimization of environmental impact, the private pursues the maximization of financial viability. Solving such trade-off design problems usually involves a big computational cost for exploring a huge solution domain including a large number of design options. To reduce that computational cost, a bi-objective simulation-based optimization algorithm, developed in a previous study, is applied in the present investigation. The algorithm is implemented for minimizing the CO2-eq emissions and the discounted payback time (DPB of a single-family house in cold climate, where 13,456 design solutions including building envelope and heating system options are explored and compared to a predefined reference case. The whole building life is considered by assuming a calculation period of 30 years. The results show that the type of heating system significantly affects energy performance; notably, the ground source heat pump leads to the highest reduction in CO2-eq emissions, around 1300 kgCO2-eq/m2, with 17 year DPB; the oil fire boiler can provide the lowest DPB, equal to 8.5 years, with 850 kgCO2-eq/m2 reduction. In addition, it is shown that using too high levels of thermal insulation is not an effective solution as it causes unacceptable levels of summertime overheating. Finally a multi-objective decision making approach is proposed in order to enable the stakeholders to choice among the optimal solutions according to the weight given to each objective, and thus to each perspective.

  9. Energy and CO{sub 2eq} analysis of the agricultural phase in the sunflower biodiesel chain

    Energy Technology Data Exchange (ETDEWEB)

    Spugnoli, C.P.; Dainelli, R.; D' avino, L.; Mazzoncini, M.; Lazzeri, L. [DEISTAF Univ. degli Studi di Firenze, Firenze (Italy)

    2010-07-01

    The suitability of the sunflower for biodiesel production was discussed in terms of the reference values on carbon dioxide equivalents (CO{sub 2eq}) emissions for every phase of the biofuels chain as indicated in the European Union (EU) Directive on renewable energies. A life cycle analysis performed on the agricultural phase of the sunflower showed that CO{sub 2eq} emissions from the cultivation phase exceeded the EU reference value. This paper highlighted the relevance of allocation methods to spread out energy consumption and CO{sub 2eq} emissions among sunflower biodiesel and oilcake. Allocation was made according to the principles of mass content, energy content and the economic value of co-products. The CO{sub 2eq} reductions obtained with the 3 methods were approximately 60, 50 and 25 per cent, respectively when compared to a case without allocation. Since these methods did not distinguish the different functionality of co-products in relation to their real use, this study also considered the method of system expansion and allocation by substitution. The considered equivalent functions of oilcake were animal feed, coal fuel and fertilizer. The results showed that while the substitution with coal gives rise to an emission credit, the others allow only minor improvements. A sensitivity analysis emphasized the significance of fossil fuels and fertilizers on energy depletion and CO{sub 2eq} emissions. It was concluded that only a major revision of farm practices aimed at reducing the use of N-fertilizer, can allow the sunflower to be suitable for biodiesel production in central Italy, given the EU constrains for CO{sub 2eq} emissions.

  10. Effects of Lowering Dialysate Calcium Concentration on Mineral and Bone Disorders in Chronic Hemodialysis Patients: Conversion from 3.0 mEq/L to 2.75 mEq/L.

    Science.gov (United States)

    Yamada, Shunsuke; Ueki, Kenji; Tokumoto, Masanori; Suehiro, Takaichi; Kimura, Hiroshi; Taniguchi, Masatomo; Fujimi, Satoru; Kitazono, Takanari; Tsuruya, Kazuhiko

    2016-02-01

    Selection of a lower dialysate calcium concentration (DCa) can reduce calcium burden and prevent vascular calcification in hemodialysis patients. However, decreased DCa can worsen mineral and bone disorders. This 1-year retrospective observational study evaluated 121 hemodialysis patients at Fukuoka Renal Clinic who underwent conversion of DCa from 3.0 mEq/L to 2.75 mEq/L. The primary outcomes were changes in serum levels of calcium, phosphate, and parathyroid hormone (PTH). The effects of baseline serum calcium and PTH levels on changes in biochemical parameters were also determined. One year after DCa conversion, mean serum calcium level decreased, while serum phosphate, alkaline phosphatase, and PTH concentrations increased. The rate of achievement of target PTH was higher in patients with lower serum PTH level at baseline, while patients with higher baseline serum PTH level tended to exceed the upper limit of the PTH target range. Patients with higher baseline serum calcium concentration showed a greater decrease in serum calcium level and a greater increase in serum PTH level at 1 year. Patients with a lower baseline serum PTH level can benefit from optimal PTH control following conversion of DCa from 3.0 mEq/L to 2.75 mEq/L. However, secondary hyperparathyroidism may be exacerbated in some patients with higher baseline serum calcium (Ca) and PTH levels. These results indicate that an individualized approach can maximize the benefits of Ca unloading after conversion to lower DCa. © 2015 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  11. Societal Preferences for EQ-5D Health States from a Brazilian Population Survey.

    Science.gov (United States)

    Viegas Andrade, Mônica; Noronha, Kenya; Kind, Paul; Maia, Ana Carolina; Miranda de Menezes, Renata; De Barros Reis, Carla; Nepomuceno Souza, Michelle; Martins, Diego; Gomes, Lucas; Nichele, Daniel; Calazans, Julia; Mascarenhas, Tamires; Carvalho, Lucas; Lins, Camila

    2013-12-01

    To elicit preference weights for a subset of EuroQol five-dimensional (EQ-5D) questionnaire health states from a representative sample for the state of Minas Gerais, Brazil, using a time trade-off (TTO) method and to analyze these data so as to estimate social preference weights for the complete set of 243 states. Data came from a valuation study with 3362 literate individuals aged between 18 and 64 years living in urban areas. The present study was based on quota sampling by age and sex. Face-to-face interviews were conducted in participants' own homes. A total of 99 EQ-5D questionnaire health states were selected, presorted into 26 blocks of six unique health states. Each participant valued one block together with the full health, worst health, and dead states. Each health state was evaluated by more than 100 individuals. TTO data were modeled at both individual and aggregate levels by using ordinary least squares and random effects methods. Values estimated by different models yielded very similar results with satisfactory goodness-of-fit statistics: the mean absolute error was around 0.03 and fewer than 25% of the states had a mean absolute error greater than 0.05. Dummies coefficients for each level within the EQ-5D questionnaire dimensions of health displayed an internally consistent ordering, with the mobility dimension demonstrating the largest value decrement. The values of mean observed transformed TTO values range from 0.869 to-0.235. The study demonstrates the feasibility of conducting face-to-face interviews using TTO in a Brazilian population setting. The estimated values for EQ-5D questionnaire health states based on this Minas Gerais survey represent an important first step in establishing national Brazilian social preference weights for the EQ-5D questionnaire. Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  12. EQ6, a computer program for reaction path modeling of aqueous geochemical systems: Theoretical manual, user's guide, and related documentation (Version 7.0)

    International Nuclear Information System (INIS)

    Wolery, T.J.; Daveler, S.A.

    1992-01-01

    EQ6 is a FORTRAN computer program in the EQ3/6 software package (Wolery, 1979). It calculates reaction paths (chemical evolution) in reacting water-rock and water-rock-waste systems. Speciation in aqueous solution is an integral part of these calculations. EQ6 computes models of titration processes (including fluid mixing), irreversible reaction in closed systems, irreversible reaction in some simple kinds of open systems, and heating or cooling processes, as well as solve ''single-point'' thermodynamic equilibrium problems. A reaction path calculation normally involves a sequence of thermodynamic equilibrium calculations. Chemical evolution is driven by a set of irreversible reactions (i.e., reactions out of equilibrium) and/or changes in temperature and/or pressure. These irreversible reactions usually represent the dissolution or precipitation of minerals or other solids. The code computes the appearance and disappearance of phases in solubility equilibrium with the water. It finds the identities of these phases automatically. The user may specify which potential phases are allowed to form and which are not. There is an option to fix the fugacities of specified gas species, simulating contact with a large external reservoir. Rate laws for irreversible reactions may be either relative rates or actual rates. If any actual rates are used, the calculation has a time frame. Several forms for actual rate laws are programmed into the code. EQ6 is presently able to model both mineral dissolution and growth kinetics

  13. EQ3/6, a software package for geochemical modeling of aqueous systems: Package overview and installation guide (Version 7.0)

    International Nuclear Information System (INIS)

    Wolery, T.J.

    1992-01-01

    EQ3/6 is a software package for geochemical modeling of aqueous systems. This report describes version 7.0. The major components of the package include: EQ3NR, a speciation-solubility code; EQ6, a reaction path code which models water/rock interaction or fluid mixing in either a pure reaction progress mode or a time mode; EQPT, a data file preprocessor, EQLIB, a supporting software library; and five supporting thermodynamic data files. The software deals with the concepts of thermodynamic equilibrium, thermodynamic disequilibrium, and reaction kinetics. The five supporting data files contain both standard state and activity coefficient-related data. Three support the use of the Davies or B equations for the activity coefficients; the other two support the use of Pitzer's equations. The temperature range of the thermodynamic data on the data files varies from 25 degree C only to 0--300 degree C. EQPT takes a formatted data file (a data0 file) and writes an unformatted near-equivalent called a datal file, which is actually the form read by EQ3NR and EQ6. EQ3NR is useful for analyzing groundwater chemistry data, calculating solubility limits, and determining whether certain reactions are in states of partial equilibrium or disequilibrium. It is also required to initialize an EQ6 calculation. EQ6 models the consequences of reacting an aqueous solution with a set of reactants which react irreversibly. It can also model fluid mixing and the consequences of changes in temperature. This code operates both in a pure reaction progress frame and in a time frame

  14. Health-related quality of life in pregnant women living with HIV: a comparison of EQ-5D and SF-12.

    Science.gov (United States)

    Wang, Xiaowen; Guo, Guangping; Zhou, Ling; Zheng, Jiarui; Liang, Xiumin; Li, Zhanqin; Luo, Hongzhuan; Yang, Yuyan; Yang, Liyuan; Tan, Ting; Yu, Jun; Lu, Lin

    2017-08-30

    This paper investigates the properties and performance of the two generic measures, EQ-5D and SF-12, for Health-Related Quality of Life (HRQoL) assessments of pregnant women living with HIV in Kunming City, Yiliang County, Daguan County, Longchuan County, Tengchong County, Longling County and Fengqing County in Yunnan Province, China. As part of a screening programme for the prevention of mother-to-child transmission of HIV (PMTCT), a retrospective cross-sectional survey was conducted in the seven Maternal and Infant Health Care centers in Yunnan Province, China, between April and June of 2016. The demographic and HIV infection-related information used in the study was collected through questionnaires designed by the study's staff. HRQoL information was collected using two generic scales: EQ-5D and SF-12. A total sample of one hundred and one pregnant women with a mean age of 30.4 ± 5.1 years was investigated. Average time elapsed since infection diagnoses was 5.8 ± 3.4 years. Only one infant (1.0%) was HIV positive, and 56 (55.4%) infants were HIV negative. The HIV status of 44 (43.6%) infants was unknown. The relationship between the EQ-5D functional dimensions and the PCS-12 and the relationship between the EQ-5D anxiety/depression dimension and the MCS-12 were stronger. Those whose PCS-12 and MCS-12 scores were at the median or lower were classified as being in worse health, while those over the median were classified as being in better health. Respondents who reported no problem on each of the EQ-5D dimensions was divided according to the median SF-12 component scores. Those who scored at the median or lower than the median were classified as being in worse health, while those higher than the median were classified as being in better health. The VAS scores were also significantly different than the median split of the SF-12 scores for these subjects. EQ-5D and SF-12 showed a discrimination ability in measuring the HRQoL of pregnant women living with

  15. Supplement to nuclear EQ sourcebook: A compilation of documents for nuclear equipment qualification

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    In the nuclear power industry, environmental and seismic qualification of safety-related electrical and instrumentation equipment is collectively known as Equipment Qualification (EQ). Related technology, as well as regulatory requirements, have evolved rapidly during the last 15 years. For environmental qualification, what began in 1971 with one trial-use guide (IEEE Std 323-1971), now stands as a full complement of Nuclear Regulatory Commission (NRC) rules, guides, and industry standards. As the original 1992 version of the Nuclear EQ Sourcebook was compiled to serve the user-community need for a complete and exhaustive single source of nuclear EQ documentation, this Supplement is published to provide the user community with nuclear EQ documentation revisions and updates that have been published since the publication of the original volume in May of 1992. The first volume of this publication included documents issued before December, 1991. That first volume was well received and also prompted positive response from industry on its usefulness and on recommendations to improve the completeness and enhance the ease of use. This Supplement, therefore, includes new documents, revisions, and updates issued and published since December 1991 and up to and including March 1993. It incorporates various enhancements in order to better serve the user community. One such enhancement included in this Supplement is the new Equipment Classification Index that is described in the User Guide section of this publication. 37 papers, including Bulletins, Federal rules, Generic Letters, Notices, Regulatory Guides, IEEE Standards, IEEE Recommended Practices, and IEEE Guides, have been processed separately for inclusion on the data base

  16. Psychometric properties of the Serbian version of the Empathy Quotient (S-EQ

    Directory of Open Access Journals (Sweden)

    Dimitrijević Aleksandar

    2012-01-01

    Full Text Available In the present study we examined psychometric properties of the Serbian translation of the Empathy Quotient scale (S-EQ. The translated version of the EQ was applied on a sample of 694 high-school students. A sub-sample consisting of 375 high-school students also completed the Interpersonal Reactivity Index (IRI, another widely used empathy measure. The following statistical analyses were applied: internal consistency analysis, explanatory (EFA and confirmatory (CFA factor analyses, and factor congruence analysis. Correlation with IRI and gender differences were calculated to demonstrate validity of the instrument. Results show that the Serbian 40-item version of EQ has lower reliability (Cronbach’s alpha = .782 than the original. The originally proposed one factor structure of the instrument was not confirmed. The short version with 28 items showed better reliablity (alpha= .807. The three-factor solution (cognitive empathy, emotional reactivity, and social skills showed good cross-sample stability (Tucker congruence coefficient over .8 but the results of CFA confirmed the solution proposed in the reviewed literature only partially. The mean scores are similar to those obtained in the other studies, and, as expected, women have significantly higher scores than men. Correlations with all subscales of IRI are statistically significant for the first two subscales of EQ, but not for the „social skills.” We concluded that the Serbian version of the „Empathy Quotient” is a useful research tool which can contribute to cross-cultural studies of empathy, although its psychometric characteristics are not as good as those obtained in the original study. We also suggest that a 28-item should be used preferably to the original 40-item version. [Projekat Ministarstva nauke Republike Srbije, br. 179018: Identification, measurement and development of cognitive and emotional competences important for a society oriented to European integrations

  17. Inequalities in Health Status from EQ-5D Findings: A Cross-Sectional Study in Low-Income Communities of Bangladesh

    Science.gov (United States)

    Sultana, Marufa; Sarker, Abdur Razzaque; Mahumud, Rashidul Alam; Ahmed, Sayem; Ahmed, Wahid; Chakrovorty, Sanchita; Rahman, Hafizur; Islam, Ziaul; Khan, Jahangir A. M.

    2016-01-01

    Background: Measuring health status by using standardized and validated instrument has become a growing concern over the past few decades throughout the developed and developing countries. The aim of the study was to investigate the overall self-reported health status along with potential inequalities by using EuroQol 5 dimensions (EQ-5D) instrument among low-income people of Bangladesh. Methods: A cross-sectional household survey was conducted in Chandpur district of Bangladesh. Bangla version of the EQ-5D questionnaire was employed along with socio-demographic information. EQ-5D questionnaire composed of 2-part measurements: EQ-5D descriptive system and the visual analogue scale (VAS). For measuring health status, UK-based preference weights were applied while higher score indicated better health status. For facilitating the consistency with EQ-5D score, VASs were converted to a scale with scores ranging from 0 to 1. Multiple logistic regression models were also employed to examine differences among EQ-5D dimensions. Results: A total of 1433 respondents participated in the study. The mean EQ-5D and VAS score was 0.76 and 0.77, respectively. The females were more likely to report any problem than the males (P economic and demographic inequalities in health status was observed in the study. Study suggests to do further investigation with country representative sample to measure the inequalities of overall health status. It would be helpful for policy-maker to find a new way aiming to reduce such inequalities. PMID:27239879

  18. Understanding the relationship between the EQ-5D, SF-6D, HAQ and disease activity in inflammatory arthritis.

    LENUS (Irish Health Repository)

    Adams, Roisin

    2012-02-01

    BACKGROUND: The growth of economic analyses and in particular cost-utility analyses (CUA), which use the QALY as a measure of outcome, has heightened the interest in the methodologies used to calculate the QALY. The EQ-5D has produced quite different utility values from that of the SF-6D. This article seeks to understand these differences using a cohort of patients with inflammatory arthritis. OBJECTIVE: To examine the relationship between the disease-specific measure, Health Assessment Questionnaire (HAQ) disability index (DI) and the preference-based measures, SF-6D, EQ-5D and European League Against Arthritis (EULAR) Disease Activity Score (DAS) in patients with rheumatoid arthritis (RA) and psoriatic arthritis (PsA). METHODS: Patients with RA and PsA (n = 504) attending a tertiary rheumatology referral centre completed the HAQ, SF-6D and the EQ-5D before starting biological therapy and again 12 months later. The SF-36 was converted into a utility using the preference-based SF-6D. Clinical outcomes such as the DAS, joint counts and laboratory measures were also recorded. We calculated single index utility scores from the preference-based instruments using UK population norms. We used regression analysis to derive a mapping function and calculated utility scores from the HAQDI and the DAS 28. RESULTS: The mean utility observed at baseline for RA was 0.43 for the EQ-5D and 0.54 for the SF-6D and for PsA was 0.49 for the EQ-5D and 0.57 for the SF-6D. The utility gain demonstrated by the EQ-5D was over twice that of the SF-6D. The EQ-5D scored 17% of the RA group as less than 0 (state defined as worse than death); 7% of this group remained less than 0 at follow-up. The distribution of the utility estimates was similar for both RA and PsA. CONCLUSIONS: Our findings draw attention to the impact of states worse than death on the overall distribution for the EQ-5D derived utilities and how these impact on its use in practice. EQ-5D-derived QALY changes are over twice

  19. Cross-cultural measurement equivalence of the EQ-5D-5L items for English-speaking Asians in Singapore.

    Science.gov (United States)

    Luo, N; Wang, Y; How, C H; Wong, K Y; Shen, L; Tay, E G; Thumboo, J; Herdman, M

    2015-06-01

    To investigate how the response labels of the 5-level EQ-5D (EQ-5D-5L) items are interpreted and used by English-speaking Chinese and non-Chinese Singaporeans, as a means to assessing whether those items are cross-culturally equivalent health-status measures in this Asian population. In face-to-face interviews, Chinese, Malay and Indian visitors to a primary care institution in Singapore were asked to rate the relative severity conveyed by EQ-5D-5L response labels, each containing the keyword of 'no(t),' 'slight(ly),' 'moderate(ly),' 'severe(ly),' or 'unable'/'extreme(ly),' using a 0-100 numerical rating scale. Participants were also asked to describe 25 hypothetical health states using the EQ-5D-5L response labels. Differences between Chinese and Malay/Indian participants in label interpretation and selection were examined using multivariate regression analysis to adjust for participant characteristics. The differences in adjusted mean severity scores for individual EQ-5D-5L labels between Chinese (n = 148) and non-Chinese (Malay: n = 53; Indian: n = 56) participants ranged from 0.0 to 9.0. The relative severity of the labels to the participants supported the ordinality of the EQ-5D-5L response labels and was similar across ethnic groups. Chinese and non-Chinese participants selected similar response labels to describe each hypothetical health state, with the adjusted odds ratios of selecting any type of the five response labels for non-Chinese versus Chinese participants ranging from 0.92 to 1.15 (p > 0.05 for all). The EQ-5D-5L items are likely to generate equivalent health outcomes between English-speaking Chinese and non-Chinese Singaporeans.

  20. Quality of life profile and psychometric properties of the EQ-5D-5L in HIV/AIDS patients

    Directory of Open Access Journals (Sweden)

    Tran Bach

    2012-11-01

    Full Text Available Abstract Objectives We assessed health-related quality of life (HRQOL, its associated factors, and examined measurement properties of the EuroQol - 5 Dimensions - 5 Levels (EQ-5D-5L in HIV/AIDS patients. Methods A cross-sectional multi-site survey was conducted in 1016 patients (age: 35.4 ± 7.0 years; 63.8% male in three epicenters of Vietnam. Internal consistency reliability, convergent validity, and discriminative validity of the EQ-5D-5L and a visual analogue scale (VAS were evaluated. Tobit censored regression models were used to identify predictors of HRQOL in HIV/AIDS patients. Results The mean EQ-5D-5L single index and VAS were 0.65 (95% Confidence Interval (CI = 0.63; 0.67 and 70.3 (95% CI = 69.2; 71.5. Cronbach’s alpha of five dimensions was 0.85. EQ-5D-5L has a good convergent validity with VAS (0.73. It discriminated patients at different HIV/AIDS stages, duration of ART, and CD4 cell count. Predictors of poorer HRQOL included being female, lower education level, unemployment, alcohol and drug use, CD4 Conclusion The EQ-5D-5L has good measurement properties in HIV/AIDS patients and holds potentials for monitoring ART outcomes. Integration of HRQOL measurement using EQ-5D-5L in HIV/AIDS clinical practice could be helpful for economic evaluation of HIV/AIDS interventions.

  1. Preliminary validation and principal components analysis of the Control of Eating Questionnaire (CoEQ) for the experience of food craving.

    Science.gov (United States)

    Dalton, M; Finlayson, G; Hill, A; Blundell, J

    2015-12-01

    The Control of Eating Questionnaire (CoEQ) comprises 21-items that are designed to assess the severity and type of food cravings an individual experiences over the previous 7 days. The CoEQ has been used in clinical trials as a multi-dimensional measure of appetite, craving and mood regulation however its underlying component structure has yet to be determined. The current paper has two aims; (1) to examine the psychometric properties, and internal consistency of the CoEQ; and (2) to provide a preliminary examination of the underlying components by exploring their construct and predictive validity. Data were pooled from four studies in which a total 215 adults (80% women; Age=29.7 ± 10.3; BMI=26.5 ± 5.2) had completed the CoEQ alongside measures of psychometric eating behaviour traits, ad libitum food intake, and body composition. A principal components analysis (PCA) and parallel analysis was conducted to examine the underlying structure of the questionnaire. The resulting subscales were tested for internal consistency (Cronbach's α=0.66-0.88). PCA revealed four components that explained 54.5% of the variance. The components were identified as: Craving Control, Positive Mood, Craving for Sweet, and Craving for Savoury. Associations between the underlying CoEQ subscales and measures of body composition and eating behaviour traits confirmed construct validity of the subscales. The associations between the subscales and snack food selection and intake of palatable snack foods supported the CoEQ's predictive validity. The CoEQ has good psychometric properties with a clear component structure and acceptable internal consistency. This preliminary validation supports the CoEQ as a measure of the experience of food cravings.

  2. EQ3/6, a software package for geochemical modeling of aqueous systems: Package overview and installation guide (Version 7.0)

    Energy Technology Data Exchange (ETDEWEB)

    Wolery, T.J.

    1992-09-14

    EQ3/6 is a software package for geochemical modeling of aqueous systems. This report describes version 7.0. The major components of the package include: EQ3NR, a speciation-solubility code; EQ6, a reaction path code which models water/rock interaction or fluid mixing in either a pure reaction progress mode or a time mode; EQPT, a data file preprocessor, EQLIB, a supporting software library; and five supporting thermodynamic data files. The software deals with the concepts of thermodynamic equilibrium, thermodynamic disequilibrium, and reaction kinetics. The five supporting data files contain both standard state and activity coefficient-related data. Three support the use of the Davies or B-dot equations for the activity coefficients; the other two support the use of Pitzer`s equations. The temperature range of the thermodynamic data on the data files varies from 25{degree}C only to 0--300{degree}C. EQPT takes a formatted data file (a data0 file) and writes an unformatted near-equivalent called a datal file, which is actually the form read by EQ3NR and EQ6. EQ3NR is useful for analyzing groundwater chemistry data, calculating solubility limits, and determining whether certain reactions are in states of partial equilibrium or disequilibrium. It is also required to initialize an EQ6 calculation. EQ6 models the consequences of reacting an aqueous solution with a set of reactants which react irreversibly. It can also model fluid mixing and the consequences of changes in temperature. This code operates both in a pure reaction progress frame and in a time frame.

  3. Validity of the EQ-5D as a generic health outcome instrument in a heroin-dependent population

    NARCIS (Netherlands)

    van der Zanden, Bart P.; Dijkgraaf, Marcel G. W.; Blanken, Peter; de Borgie, Corianne A. J. M.; van Ree, Jan M.; van den Brink, Wim

    2006-01-01

    OBJECTIVE: To evaluate the validity of the EuroQol (EQ-5D) in a population of chronic, treatment-resistant heroin-dependent patients. METHODS: The EQ-5D is studied relative to the Maudsley Addiction Profile (MAP), the Symptom Checklist (SCL-90) and the European Addiction Severity Index (EuropASI)

  4. Mapping EORTC QLQ-C30 onto EQ-5D for the assessment of cancer patients

    Directory of Open Access Journals (Sweden)

    Kim Seon Ha

    2012-12-01

    Full Text Available Abstract Background The European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire Core 30 (EORTC QLQ-C30 is the instrument most frequently used to measure quality of life in cancer patients, whereas the EQ-5D is widely used to measure and evaluate general health status. Although the EORTC QLQ-C30 has been mapped to EQ-5D utilities, those studies were limited to patients with a single type of cancer. The present study aimed to develop a mapping relationship between the EORTC QLQ-C30 and EQ-5D-based utility values at the individual level. Methods The model was derived using patients with different types of cancer who were receiving chemotherapy. The external validation set comprised outpatients with colon cancer. Ordinary least squares regression was used to estimate the EQ-5D index from the EORTC QLQ-C30 results. The predictability, goodness of fit, and signs of the estimated coefficients of the model were assessed. Predictive ability was determined by calculating the mean absolute error, the estimated proportions with absolute errors > 0.05 and > 0.1, and the root-mean-squared error (RMSE. Results A model that included global health, physical, role, emotional functions, and pain was optimal, with a mean absolute error of 0.069 and an RMSE of 0.095 (normalized RMSE, 8.1%. The explanatory power of this model was 51.6%. The mean absolute error was higher for modeled patients in poor health. Conclusions This mapping algorithm enabled the EORTC QLQ-C30 to be converted to the EQ-5D utility index to assess cancer patients in Korea.

  5. EQPT, a data file preprocessor for the EQ3/6 software package: User's guide and related documentation (Version 7.0)

    International Nuclear Information System (INIS)

    Daveler, S.A.; Wolery, T.J.

    1992-01-01

    EQPT is a data file preprocessor for the EQ3/6 software package. EQ3/6 currently contains five primary data files, called datao files. These files comprise alternative data sets. These data files contain both standard state and activity coefficient-related data. Three (com, sup, and nea) support the use of the Davies or B equations for the activity coefficients; the other two (hmw and pit) support the use of Pitzer's (1973, 1975) equations. The temperature range of the thermodynamic data on these data files varies from 25 degrees C only to 0-300 degrees C. The principal modeling codes in EQ3/6, EQ3NR and EQ6, do not read a data0 file, however. Instead, these codes read an unformatted equivalent called a data1 file. EQPT writes a datal file, using the corresponding data0 file as input. In processing a data0 file, EQPT checks the data for common errors, such as unbalanced reactions. It also conducts two kinds of data transformation. Interpolating polynomials are fit to data which are input on temperature adds. The coefficients of these polynomials are then written on the datal file in place of the original temperature grids. A second transformation pertains only to data files tied to Pitzer's equations. The commonly reported observable Pitzer coefficient parameters are mapped into a set of primitive parameters by means of a set of conventional relations. These primitive form parameters are then written onto the datal file in place of their observable counterparts. Usage of the primitive form parameters makes it easier to evaluate Pitzer's equations in EQ3NR and EQ6. EQPT and the other codes in the EQ3/6 package are written in FORTRAN 77 and have been developed to run under the UNIX operating system on computers ranging from workstations to supercomputers

  6. An EQ-5D-5L value set based on Uruguayan population preferences.

    Science.gov (United States)

    Augustovski, Federico; Rey-Ares, Lucila; Irazola, Vilma; Garay, Osvaldo Ulises; Gianneo, Oscar; Fernández, Graciela; Morales, Marcelo; Gibbons, Luz; Ramos-Goñi, Juan Manuel

    2016-02-01

    To derive a value set from Uruguayan general population using the EQ-5D-5L questionnaire and report population norms. General population individuals were randomly assigned to value 10 health states using composite time trade off and 7 pairs of health states through discrete choice experiments. A stratified sampling with quotas by location, gender, age and socio-economic status was used to respect the Uruguayan population structure. Trained interviewers conducted face-to-face interviews. The EuroQol valuation technology was used to administer the protocol as well as to collect the data. OLS and maximum likelihood robust regression models with or without interactions were tested. We included 794 respondents between 20 and 83 years. Their characteristics were broadly similar to the Uruguayan population. The main effects robust model was chosen to derive social values. Values ranged from -0.264 to 1. States with a misery index = 6 had a mean predicted value of 0.965. When comparing the Uruguayan population with the Argentinian EQ-5D-5L crosswalk value set, the prediction for states which differed from full health only in having one of the dimensions at level 2 were about 0.05 higher in Uruguay. The mean index value, using the selected Uruguayan EQ-5D-5L value set, for the general population in Uruguay was 0.895. In general, older people had worse values and males had slightly better values than females. We derived the EQ-5D-5L Uruguayan value set, the first in Latin America. These results will help inform decision-making using economic evaluations for resource allocation decisions.

  7. Comparing UK, USA and Australian values for EQ-5D as a health utility measure of oral health.

    Science.gov (United States)

    Brennan, D S; Teusner, D N

    2015-09-01

    Using generic measures to examine outcomes of oral disorders can add additional information relating to health utility. However, different algorithms are available to generate health states. The aim was to assess UK-, US- and Australian-based algorithms for the EuroQol (EQ-5D) in relation to their discriminative and convergent validity. Methods: Data were collected from adults in Australia aged 30-61 years by mailed survey in 2009-10, including the EQ-5D and a range of self-reported oral health variables, and self-rated oral and general health. Responses were collected from n=1,093 persons (response rate 39.1%). UK-based EQ-5D estimates were lower (0.85) than the USA and Australian estimates (0.91). EQ-5D was associated (pUSA, and from 0.05 to 0.08 for the Australian-based estimates. The effect sizes (ESs) of the associations with all seven oral health variables were similar for the UK (ES=0.26 to 0.49), USA (ES=0.31 to 0.48) and Australian-based (ES=0.31 to 0.46) estimates. EQ-5D was correlated with global dental health for the UK (rho=0.29), USA (rho=0.30) and Australian-based estimates (rho=0.30), and correlations with global general health were the same (rho=0.42) for the UK, USA and Australian-based estimates. EQ-5D exhibited equivalent discriminative validity and convergent validity in relation to oral health variables for the UK, USA and Australian-based estimates.

  8. Experience-based VAS values for EQ-5D-3L health states in a national general population health survey in China.

    Science.gov (United States)

    Sun, Sun; Chen, Jiaying; Kind, Paul; Xu, Ling; Zhang, Yaoguang; Burström, Kristina

    2015-03-01

    To investigate the feasibility of deriving experience-based visual analogue scale (VAS) values for EQ-5D-3L health states using national general population health survey data in China. The EQ-5D-3L was included in the National Health Services Survey (n = 120,709, aged 15-103 years) to measure health-related quality of life. The respondents reported their current health status on a VAS and completed the EQ-5D-3L questionnaire, enabling modelling of the association between the experience-based VAS values and self-reported problems on EQ-5D dimensions and severity levels. VAS values were generally negatively associated with problems reported on the EQ-5D dimensions, and the anxiety/depression dimension had the greatest impact on VAS values. A previously obtained value for dead allowed the values for all 243 EQ-5D-3L health states to be transformed to the 0-1 scale (0 = dead, 1 = full health). This study presents the feasibility of deriving an experience-based VAS values for EQ-5D-3L health states in China. The analysis of these VAS data raises more fundamental issues concerning the universal nature of the classification system and the extent to which Chinese respondents utilise the same concepts of health as defined by this classification system.

  9. Mapping of the DLQI scores to EQ-5D utility values using ordinal logistic regression.

    Science.gov (United States)

    Ali, Faraz Mahmood; Kay, Richard; Finlay, Andrew Y; Piguet, Vincent; Kupfer, Joerg; Dalgard, Florence; Salek, M Sam

    2017-11-01

    The Dermatology Life Quality Index (DLQI) and the European Quality of Life-5 Dimension (EQ-5D) are separate measures that may be used to gather health-related quality of life (HRQoL) information from patients. The EQ-5D is a generic measure from which health utility estimates can be derived, whereas the DLQI is a specialty-specific measure to assess HRQoL. To reduce the burden of multiple measures being administered and to enable a more disease-specific calculation of health utility estimates, we explored an established mathematical technique known as ordinal logistic regression (OLR) to develop an appropriate model to map DLQI data to EQ-5D-based health utility estimates. Retrospective data from 4010 patients were randomly divided five times into two groups for the derivation and testing of the mapping model. Split-half cross-validation was utilized resulting in a total of ten ordinal logistic regression models for each of the five EQ-5D dimensions against age, sex, and all ten items of the DLQI. Using Monte Carlo simulation, predicted health utility estimates were derived and compared against those observed. This method was repeated for both OLR and a previously tested mapping methodology based on linear regression. The model was shown to be highly predictive and its repeated fitting demonstrated a stable model using OLR as well as linear regression. The mean differences between OLR-predicted health utility estimates and observed health utility estimates ranged from 0.0024 to 0.0239 across the ten modeling exercises, with an average overall difference of 0.0120 (a 1.6% underestimate, not of clinical importance). This modeling framework developed in this study will enable researchers to calculate EQ-5D health utility estimates from a specialty-specific study population, reducing patient and economic burden.

  10. An exploration of differences between Japan and two European countries in the self-reporting and valuation of pain and discomfort on the EQ-5D.

    Science.gov (United States)

    Feng, Yan; Herdman, Mike; van Nooten, Floortje; Cleeland, Charles; Parkin, David; Ikeda, Shunya; Igarashi, Ataru; Devlin, Nancy J

    2017-08-01

    To investigate the systematic differences in the self-reporting and valuation of overall health and, in particular, pain/discomfort between three countries (England/UK, Japan, and Spain) on the EQ-5D. Existing datasets were used to explore differences in responses on the EQ-5D descriptive system between Japan (3L and 5L), the UK (3L), England (5L), and Spain (5L), particularly on the dimension of pain/discomfort. The role of different EQ dimensions in determining self-reported overall health scores for the EuroQol visual analog scale (EQ-VAS) was investigated using ordinary least squares regression. Time trade-off (TTO) results from Japanese and UK respondents for the EQ-5D-3L as well as Japanese and English respondents for the EQ-5D-5L were compared using t tests. For the EQ-5D-3L, a higher percentage of respondents in Japan than in the UK reported 'no pain/discomfort' (81.6 vs 67.0%, respectively); for the EQ-5D-5L, the proportions were 79.2% in Spain, 73.2% in Japan, and 63-64% in England, after adjusting for age differences in samples. The 'pain/discomfort' dimension had the largest impact on respondents' self-reported EQ-VAS only for EQ-5D-3L in Japan. Using the EQ-5D-3L, Japanese respondents were considerably less willing to trade off time to avoid pain/discomfort than the UK respondents; for example, moving from health state, 11121 (some problems with pain/discomfort) to 11131 (extreme pain/discomfort) represented a decrement of 0.65 on the observed TTO value in the UK compared with 0.15 in Japan. Using the EQ-5D-5L, Japanese respondents were also less willing to trade off time to avoid pain/discomfort than respondents in England; however, the difference in values was much smaller than that observed using EQ-5D-3L data. This study provides evidence of between-country differences in the self-reporting and valuation of health, including pain/discomfort, when using EQ-5D in general population samples. The results suggest a need for caution when comparing or

  11. Revisão de 26 casos clínicos de duodeno-jejunite proximal em eqüinos (1996-2000

    Directory of Open Access Journals (Sweden)

    Fernandes Wilson Roberto

    2003-01-01

    Full Text Available Os dados de 26 eqüinos com duodeno-jejunite proximal (DJP, examinados no HOVET-FMVZ-USP entre dezembro de 1996 e novembro de 2000, foram revisados. Durante esse período, foram atendidos 1555 animais, dos quais 205 apresentavam distúrbios gastrintestinais (13,2%. Os casos de DJP representaram 1,7% do total de eqüinos atendidos. A idade, os achados clínico-laboratoriais e a evolução clínica foram comparados entre eqüinos sobreviventes (grupo 1 e eqüinos não sobreviventes (grupo 2. Vinte eqüinos (76,9% sobreviveram. Todos os animais foram submetidos exclusivamente a tratamento médico. A análise dos resultados foi feita através de comparação entre médias pelo teste t de Student com significância de 5%. Houve diferença significativa entre os dois grupos em relação aos seguintes parâmetros analisados: contagem total de leucócitos no sangue, creatinina sérica e freqüência cardíaca. A principal complicação nos animais recuperados foi laminite (30,8%.

  12. Testing mapping algorithms of the cancer-specific EORTC QLQ-C30 onto EQ-5D in malignant mesothelioma

    NARCIS (Netherlands)

    D.T. Arnold (David); D. Rowen (Donna); M.M. Versteegh (Matthijs); A. Morley (Anna); C.E. Hooper (Clare); N.A. Maskell (Nicholas)

    2015-01-01

    markdownabstract__Background:__ In order to estimate utilities for cancer studies where the EQ-5D was not used, the EORTC QLQ-C30 can be used to estimate EQ-5D using existing mapping algorithms. Several mapping algorithms exist for this transformation, however, algorithms tend to lose accuracy in

  13. Intoxicação em eqüino por Ricinus communis: relato de caso.

    Directory of Open Access Journals (Sweden)

    R. Y. A. Baccarin

    2005-03-01

    Full Text Available RESUMO: A intoxicação por Ricinus communis (Euphorbiaceae geralmente ocorre após a ingestão acidental de suas folhas ou sementes, podendo causar distúrbios neuromusculares e gastrintestinais. Um eqüino da raça Mangalarga Marchador de 4 anos de idade foi atendido no setor de Clínica de Eqüinos do Hospital Veterinário (HOVET da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo (FMVZ-USP após ter ingerido e aspirado um filtrado preparado à base de frutos de mamona. O animal apresentava pleuropneumonia, alterações de comportamento, comprometimentos hepático e renal, peritonite e desidratação. PALAVRAS-CHAVE: Eqüino, Ricinus communis, pleuropneumonia. SUMMARY: The Ricinus communis (Euphorbiaceae intoxication generally occurs after accidental ingestion of its leaves or seeds, and may cause neuromuscular and gastrintestinal disturbance. An equine, Mangalarga Marchador breed, 4-year old, was attended at the section of Clínica de Eqüinos from the Hospital Veterinário (HOVET of Faculdade de Medicina Veterinária e Zootecnia of Universidade de São Paulo (FMVZ-USP after ingestion and aspiration of a R. communis fruits filtrate. The animal presented pleuropneumonia, behavioural alterations, hepatic and renal disturbances, peritonitis and dehydration. KEYWORDS: Equine, Ricinus communis, pleuropneumonia.

  14. Cardiotoxicity of tricyclic antidepressant treated by 2650 mEq sodium bicarbonate: A case report.

    Science.gov (United States)

    Amiri, Hassan; Zamani, Nasim; Hassanian-Moghaddam, Hossein; Shadnia, Shahin

    2016-01-01

    Poisoning with tricyclic antidepressants is an important cause of drug-related self-poisoning in the developed world and a very common cause of poisoning and mortality in developing countries. Electrocardiographic manifestations of most tricyclic antidepressant-poisoned patients resolve by the administration of 1-2 mEq/kg of sodium bicarbonate. Some rare cases have been reported who have been resistant to the long-term or high doses of bicarbonate administration. We present a case of acute tricyclic antidepressant toxicity referring with status epilepticus, hypotension, and refractory QRS complex widening that resolved after the intravenous administration of 2650 mEq sodium bicarbonate.

  15. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control.

    Science.gov (United States)

    Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick

    2015-01-01

    This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.

  16. An analysis of Euroqol EQ-5D and Manchester Oxford Foot Questionnaire scores six months following podiatric surgery.

    Science.gov (United States)

    Maher, Anthony J; Kilmartin, Timothy E

    2012-07-09

    In the United Kingdom patient-reported outcome measures (PROMS) have been adopted as a key measure of foot surgery outcomes. The intention of this study was to evaluate the responsiveness of a regional outcome measure; the Manchester Oxford Foot Questionnaire (MOXFQ) and a generic measure; the EuroQol EQ-5D, in the context of day care Podiatric Surgery. A prospective audit of 375 consecutive day care surgical admissions was undertaken. All patients attending for surgery, who agreed to participate, were included. Pre operation patients completed the MOXFQ and the EQ-5D. Both questionnaires were completed again at 6 months post operation. Additional data was collected on patient demographics, surgical procedures and complications. Few complications were encountered and most patients (84%) returned for a final review 6 months post operation. Mean MOXFQ scores improved for each domain: pain; 51.7 pre-operation, reduced to 16.5 post-operation, walking; 50.2 reduced to 14.1 and social interaction; 45.7 reduced to 10.6. The minimal clinically important differences (MCID) estimates for the pain domain were exceeded by 82.6% of patients, while 74.8% exceeded the MCID for walking and 68.5% exceeded the MCID for social interaction. A small number of patients (2.9%) deteriorated across all three MOXFQ domains.The EQ-5D Index, summary of health related quality of life, improved from 0.66 pre-operation to 0.86 post operation. The EQ-5D index MCID was exceeded by 79.2% of patients. Index scores deteriorated for 1.8% of patients following surgery. Effect sizes measured following surgery were largest for the MOXFQ domains: Walking; 1.39, Pain; 1.52 and Social Interaction: 1.39. The EQ-5D index effect size was 0.83. The EQ-5D visual analogue scale (VAS) was not influenced by surgery. Both the MOXFQ and EQ-5D index (but not the VAS) appear sensitive to changes in health status at 6 months following elective foot surgery. Both instruments were particularly responsive to changes

  17. Assessment of the Swedish EQ-5D experience-based value sets in a total hip replacement population.

    Science.gov (United States)

    Nemes, Szilárd; Burström, Kristina; Zethraeus, Niklas; Eneqvist, Ted; Garellick, Göran; Rolfson, Ola

    2015-12-01

    All patients undergoing elective total hip replacement (THR) in Sweden are asked to complete a survey, including the EQ-5D. Thus far, EQ-5D values have been presented using the UK TTO value set based on hypothetical values. Shift to the use of the recently introduced Swedish experience-based value set, derived from a representative Swedish population, is an appealing alternative. To investigate how accurate the Swedish experience-based VAS value set predicts observed EQ VAS values and to compare correlations between Swedish and UK value sets including two provisional value sets derived from the THR population. Pre- and one-year postoperative data from 56,062 THR patients from the Swedish Hip Arthroplasty Register were used. Agreement between the observed and the predicted EQ VAS values was assessed with correlation. Based on pre- and postoperative data, we constructed two provisional VAS value sets. Correlations between observed and calculated values using the Swedish VAS value set were moderate (r = 0.46) in preoperative data and high (r = 0.72) in postoperative data. Correlations between UK and register-based value sets were constantly lower compared to Swedish value sets. Register-based values and Swedish values were highly correlated. The Swedish value sets are more accurate in terms of representation of the Swedish THR patients than the currently used UK TTO value set. We find it feasible to use the experience-based Swedish value sets for further presentation of EQ-5D values in the Swedish THR population.

  18. EQ6, a computer program for reaction path modeling of aqueous geochemical systems: Theoretical manual, user`s guide, and related documentation (Version 7.0); Part 4

    Energy Technology Data Exchange (ETDEWEB)

    Wolery, T.J.; Daveler, S.A.

    1992-10-09

    EQ6 is a FORTRAN computer program in the EQ3/6 software package (Wolery, 1979). It calculates reaction paths (chemical evolution) in reacting water-rock and water-rock-waste systems. Speciation in aqueous solution is an integral part of these calculations. EQ6 computes models of titration processes (including fluid mixing), irreversible reaction in closed systems, irreversible reaction in some simple kinds of open systems, and heating or cooling processes, as well as solve ``single-point`` thermodynamic equilibrium problems. A reaction path calculation normally involves a sequence of thermodynamic equilibrium calculations. Chemical evolution is driven by a set of irreversible reactions (i.e., reactions out of equilibrium) and/or changes in temperature and/or pressure. These irreversible reactions usually represent the dissolution or precipitation of minerals or other solids. The code computes the appearance and disappearance of phases in solubility equilibrium with the water. It finds the identities of these phases automatically. The user may specify which potential phases are allowed to form and which are not. There is an option to fix the fugacities of specified gas species, simulating contact with a large external reservoir. Rate laws for irreversible reactions may be either relative rates or actual rates. If any actual rates are used, the calculation has a time frame. Several forms for actual rate laws are programmed into the code. EQ6 is presently able to model both mineral dissolution and growth kinetics.

  19. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  20. A qualitative examination of the content validity of the EQ-5D-5L in patients with type 2 diabetes.

    Science.gov (United States)

    Matza, Louis S; Boye, Kristina S; Stewart, Katie D; Curtis, Bradley H; Reaney, Matthew; Landrian, Amanda S

    2015-12-01

    The EQ-5D is frequently used to derive utilities for patients with type 2 diabetes (T2D). Despite widely available quantitative psychometric data on the EQ-5D, little is known about content validity in this population. Thus, the purpose of this qualitative study was to examine content validity of the EQ-5D in patients with T2D. Patients with T2D in the UK completed concept elicitation interviews, followed by administration of the EQ-5D-5L and cognitive interviewing focused on the instrument's relevance, clarity, and comprehensiveness. A total of 25 participants completed interviews (52.0 % male; mean age = 53.5 years). Approximately half (52 %) reported that the EQ-5D-5L was relevant to their experience with T2D. When asked if each individual item was relevant to their experience with T2D, responses varied widely (24.0 % said the self-care item was relevant; 68.0 % said the anxiety/depression item was relevant). Participants frequently said items were not relevant to themselves, but could be relevant to patients with more severe diabetes. Most participants (92.0 %) reported that T2D and/or its treatment/monitoring requirements had an impact on their quality of life that was not captured by the EQ-5D-5L. Common missing concepts included food awareness/restriction (n = 13, 52.0 %); activities (n = 11, 44.0 %); emotional functioning other than depression/anxiety (n = 8, 32.0 %); and social/relationship functioning (n = 8, 32.0 %). The results highlight strengths and potential limitations of the EQ-5D-5L, including missing content that could be important for some patients with T2D. Suggestions for addressing limitations are provided.

  1. What matters most?: evidence-based findings of health dimensions affecting the societal preferences for EQ-5D health states

    Directory of Open Access Journals (Sweden)

    Monica Viegas Andrade

    2013-01-01

    Full Text Available This study analyzes how different health dimensions defined by the EQ-5D-3L instrument affect average individual preferences for health states. This analysis is an important benchmark for the incorporation of health technologies as it takes into consideration Brazilian population preferences in health resource allocation decisions. The EQ-5D instrument defines health in terms of five dimensions (mobility, daily activities, self-care activities, pain/discomfort, and anxiety/depression each divided into three levels of severity. Data came from a valuation study with 3,362 literate individuals aged between 18 and 64 living in urban areas of Minas Gerais State, Brazil. The main results reveal that health utility decreases as the level of severity increases. With regard to health issues, mobility stands out as the most important EQ-5D dimension. Independently of severity levels of the other EQ-5D-3L dimensions, the highest decrements in utilities are associated with severe mobility problems.

  2. Comparison of the SF6D, the EQ5D, and the oswestry disability index in patients with chronic low back pain and degenerative disc disease.

    Science.gov (United States)

    Johnsen, Lars G; Hellum, Christian; Nygaard, Oystein P; Storheim, Kjersti; Brox, Jens I; Rossvoll, Ivar; Leivseth, Gunnar; Grotle, Margreth

    2013-04-26

    underlying construct. This study indicates that the difference in important measurement properties between EQ5D and SF6D is too large to consider them interchangeable. Since the similarity with the "gold standard" (the disease-specific instrument) was quite different, this could indicate that the choice of index should be determined by the diagnosis.

  3. VOC identification and inter-comparison from laboratory biomass burning using PTR-MS and PIT-MS

    Science.gov (United States)

    C. Warneke; J. M. Roberts; P. Veres; J. Gilman; W. C. Kuster; I. Burling; R. Yokelson; J. A. de Gouw

    2011-01-01

    Volatile organic compounds (VOCs) emitted from fires of biomass commonly found in the southeast and southwest U.S. were investigated with PTR-MS and PIT-MS, which are capable of fast measurements of a large number of VOCs. Both instruments were calibrated with gas standards and mass dependent calibration curves are determined. The sensitivity of the PIT-MS linearly...

  4. Cardiotoxicity of tricyclic antidepressant treated by 2650 mEq sodium bicarbonate: A case report

    Directory of Open Access Journals (Sweden)

    Hassan Amiri

    2016-12-01

    Full Text Available Poisoning with tricyclic antidepressants is an important cause of drug-related self-poisoning in the developed world and a very common cause of poisoning and mortality in developing countries. Electrocardiographic manifestations of most tricyclic antidepressant-poisoned patients resolve by the administration of 1–2 mEq/kg of sodium bicarbonate. Some rare cases have been reported who have been resistant to the long-term or high doses of bicarbonate administration. We present a case of acute tricyclic antidepressant toxicity referring with status epilepticus, hypotension, and refractory QRS complex widening that resolved after the intravenous administration of 2650 mEq sodium bicarbonate.

  5. Modeling ion exchange in clinoptilolite using the EQ3/6 geochemical modeling code

    International Nuclear Information System (INIS)

    Viani, B.E.; Bruton, C.J.

    1992-06-01

    Assessing the suitability of Yucca Mtn., NV as a potential repository for high-level nuclear waste requires the means to simulate ion-exchange behavior of zeolites. Vanselow and Gapon convention cation-exchange models have been added to geochemical modeling codes EQ3NR/EQ6, allowing exchange to be modeled for up to three exchangers or a single exchanger with three independent sites. Solid-solution models that are numerically equivalent to the ion-exchange models were derived and also implemented in the code. The Gapon model is inconsistent with experimental adsorption isotherms of trace components in clinoptilolite. A one-site Vanselow model can describe adsorption of Cs or Sr on clinoptilolite, but a two-site Vanselow exchange model is necessary to describe K contents of natural clinoptilolites

  6. Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring

    Directory of Open Access Journals (Sweden)

    Hanne Roberg-Larsen

    2017-08-01

    Full Text Available A rugged and high throughput capillary column (cLC LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL solid phase extraction (SPE for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g., injection of 100 non-filtrated water samples did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 μm. In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for environmental water samples was demonstrated with various pharmaceutical products, which had detection limits (LOD in the 0.05–12.5 ng/L range. Between-day and within-day repeatability of selected analytes were <20% RSD.

  7. Reaction of Topopah Spring tuff with J-13 water: a geochemical modeling approach using the EQ3/6 reaction path code

    International Nuclear Information System (INIS)

    Delany, J.M.

    1985-01-01

    EQ3/6 geochemical modeling code package was used to investigate the interaction of the Topopah Spring Tuff and J-13 water at high temperatures. EQ3/6 input parameters were obtained from the results of laboratory experiments using USW G-1 core and J-13 water. Laboratory experiments were run at 150 and 250 0 C for 66 days using both wafer-size and crushed tuff. EQ3/6 modeling reproduced results of the 150 0 C experiments except for a small increase in the concentration of potassium that occurs in the first few days of the experiments. At 250 0 C, the EQ3/6 modeling reproduced the major water/rock reactions except for a small increase in potassium, similar to that noted above, and an overall increase in aluminum. The increase in potassium concentration cannot be explained at this time, but the increase in A1 concentration is believed to be caused by the lack of thermodynamic data in the EQ3/6 data base for dachiardite, a zeolite observed as a run product at 250 0 C. The ability to reproduce the majority of the experimental rock/water interactions at 150 0 C validates the use of EQ3/6 as a geochemical modeling tool that can be used to theoretically investigate physical/chemical environments in support of the Waste Package Task of NNWSI

  8. A systematic literature review to compare quality of life in psoriasis with other chronic diseases using EQ-5D-derived utility values

    Directory of Open Access Journals (Sweden)

    Møller AH

    2015-07-01

    Full Text Available Anders Holmen Møller,1 Sandra Erntoft,1 Gabrielle R Vinding,2 Gregor BE Jemec21LEO Pharma A/S, Ballerup, Denmark; 2Department of Dermatology, Roskilde Hospital, Health Sciences Faculty, University of Copenhagen, Copenhagen, DenmarkBackground: Psoriasis is a chronic, immune-mediated dermatological disease associated with substantial economic, clinical, and humanistic burden.Objective: The aim of this study was to understand the disutility of patients with psoriasis vulgaris, using mean baseline EuroQoL five dimensions (EQ-5D index scores reported in the published literature, and to compare this to patients with other chronic diseases.Methods: Two systematic literature searches were conducted according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA guidelines. Searches were conducted in ten databases including Embase, MEDLINE, and the Cochrane Central Register of Controlled Trials (CENTRAL. The first search (December 2013 used search terms psoria* AND (EQ5D OR EQ OR EUROQoL. Only publications of original research, which reported baseline EQ-5D scores for mild/moderate/severe psoriasis, were included. The second search (March 2014 used the terms (systematic review AND (EQ5D OR EQ 5D OR EuroQoL. Titles were screened by two independent reviewers. Four independent reviewers reviewed titles and full-length papers. EQ-5D scores for psoriasis patients were qualitatively compared with scores from patients with other chronic diseases identified through the literature search.Results: Of 133 publications on psoriasis, 12 met the inclusion criteria. The mean EQ-5D index scores for psoriasis (all severities ranged from 0.52 (standard deviation: 0.39 to 0.9 (standard deviation: 0.1. Of the 48 results from the second search, six met the inclusion criteria. The reported EQ-5D lower limit for other diseases ranged from 0.20 (Type 2 diabetes mellitus to 0.66 (liver diseases. The highest EQ-5D estimates for other diseases ranged

  9. Quality of Life Assessment Using EuroQOL EQ-5D Questionnaire in Patients with Deep Infiltrating Endometriosis: The Relation with Symptoms and Locations

    Science.gov (United States)

    Touboul, C.; Amate, P.; Ballester, M.; Bazot, M.; Fauconnier, A.; Daraï, E.

    2013-01-01

    The objective of this study was to evaluate the quality of life (QOL) of patients with deep infiltrating endometriosis (DIE) using EuroQOL (EQ-5D) and its correlation with symptoms and locations of endometriotic lesions. One hundred and fifty-nine patients referred for DIE from January 2011 to April 2011 were prospectively invited to complete questionnaires evaluating symptoms associated with endometriosis as well as the EQ-5D questionnaire and health state. Patients also had locations of DIE evaluated by clinical examination and magnetic resonance imaging (MRI). All 159 patients completed the questionnaires. Item response rate was 91.1%. The most intense symptoms were dysmenorrhea (7.1/10), painful defecation (6.3/10), and fatigue (6.0/10). Mean (SD) scores were 77 (14) for the EQ-5D questionnaire and 63.4 (21) for the health state. A relation was observed between the EQ-5D questionnaire and the presence of dysmenorrhea, dyspareunia, cyclic pelvic pain, painful defecation, and diarrhea or constipation. Vaginal and rectal infiltrations were significantly associated with altered EQ-5D and health state scores. The EQ-5D questionnaire is easy to complete and well related to symptoms of DIE. Rectal and vaginal infiltrations were found to be determinant factors of altered QOL by the EQ-5D questionnaire and health state. PMID:26464845

  10. Americium thermodynamic data for the EQ3/6 database

    International Nuclear Information System (INIS)

    Kerrisk, J.F.

    1984-07-01

    Existing thermodynamic data for aqueous and solid species of americium have been reviewed and collected in a form that can be used with the EQ3/6 database. Data that are important in solubility calculations for americium at a proposed Yucca Mountain nuclear waste repository were emphasized. Conflicting data exist for americium complexes with carbonates. Essentially no data are available for americium solids or complexes at temperatures greater than 25 0 C. 17 references, 4 figures

  11. Evaluating the sensitivity of EQ-5D in a sample of patients with type 2 diabetes mellitus in two tertiary health care facilities in Nigeria.

    Science.gov (United States)

    Ekwunife, Obinna Ikechukwu; Ezenduka, Charles C; Uzoma, Bede Emeka

    2016-01-12

    The EQ-5D instrument is arguably the most well-known and commonly used generic measure of health status internationally. Although the instrument has been employed in outcomes studies of diabetes mellitus in many countries, it has not yet been used in Nigeria. This study was carried out to assess the sensitivity of the EQ-5D instrument in a sample of Nigerian patients with type 2 diabetes mellitus (T2DM). A cross-sectional study was conducted using the EQ-5D instrument to assess the self-reported quality of life of patients with T2DM attending two tertiary healthcare facilities in south eastern Nigeria consenting patients completed the questionnaire while waiting to see a doctor. A priori hypotheses were examined using multiple regression analysis to model the relationship between the dependent variables (EQ VAS and EQ-5D Index) and hypothesized independent variables. A total of 226 patients with T2DM participated in the study. The average age of participants was 57 years (standard deviation 10 years) and 61.1% were male. The EQ VAS score and EQ-5D index averaged 66.19 (standard deviation 15.42) and 0.78 (standard deviation 0.21) respectively. Number of diabetic complications, number of co-morbidities, patient's age and being educated predicted EQ VAS score by -6.76, -6.15, -0.22, and 4.51 respectively. Also, number of diabetic complications, number of co-morbidities, patient's age and being educated predicted EQ-5D index by -0.12, -0.07, -0.003, and 0.06 respectively.. Our findings indicate that the EQ-5D could adequately capture the burden of type 2 diabetes and related complications among Nigerian patients.

  12. ms_lims, a simple yet powerful open source laboratory information management system for MS-driven proteomics.

    Science.gov (United States)

    Helsens, Kenny; Colaert, Niklaas; Barsnes, Harald; Muth, Thilo; Flikka, Kristian; Staes, An; Timmerman, Evy; Wortelkamp, Steffi; Sickmann, Albert; Vandekerckhove, Joël; Gevaert, Kris; Martens, Lennart

    2010-03-01

    MS-based proteomics produces large amounts of mass spectra that require processing, identification and possibly quantification before interpretation can be undertaken. High-throughput studies require automation of these various steps, and management of the data in association with the results obtained. We here present ms_lims (http://genesis.UGent.be/ms_lims), a freely available, open-source system based on a central database to automate data management and processing in MS-driven proteomics analyses.

  13. The EQ-5D (Euroqol is a valid generic instrument for measuring quality of life in patients with dyspepsia

    Directory of Open Access Journals (Sweden)

    Goh Khean-Lee

    2009-03-01

    Full Text Available Abstract Background There is little information of the validity of generic instruments in measuring health-related quality of life (HRQOL in patients with dyspepsia. We aimed to assess the reliability and validity of the EQ-5D, a brief and simple instrument, in measuring HRQOL in adult patients with dyspepsia. Methods Consecutive adults with dyspepsia attending the Gastroenterology clinic in a tertiary referral center were interviewed with the EQ-5D (both English and Malay versions, the short-form Nepean Dyspepsia Index (SF-NDI, the SF-36 and Leeds Dyspepsia Questionnaire (LDQ. Known-groups and convergent construct validity were investigated by testing hypotheses at attribute and overall levels. A repeat telephone interview was conducted 2 weeks later to assess test-retest reliability. Results A total of 113 patients (mean (SD age: 53.7 (14 years; 49.5% male; 24.8% Malays, 37.2% Chinese; 70.8% functional dyspepsia were recruited. Response rate was 100% with nil missing data. Known-groups validation revealed 20/26 hypotheses fulfillment. Patients with more severe dyspepsia reported more problems with their usual activity (p = 0.07 and pain (p = 0.06 and demonstrated lower median VAS scores (60 vs 70, p = 0.002 and EQ-5D utility scores (0.72 vs 0.78, p = 0.002. Those reporting problems in various EQ-5D dimensions had significantly lower scores in relevant SF-36 and SF-NDI dimensions. The overall EQ-5D utility score also demonstrated good correlation with the SF-36 summary physical and mental scores and the SF-NDI total score. Intraclass correlation coefficient for test-retest reliability was 0.66 (95% CI = 0.55 – 0.76. Conclusion The EQ-5D is an acceptable, valid and reliable generic instrument for measuring HRQOL in adult patients with dyspepsia.

  14. Reaction of Topopah Spring tuff with J-13 water: a geochemical modeling approach using the EQ3/6 reaction path code

    Energy Technology Data Exchange (ETDEWEB)

    Delany, J.M.

    1985-11-25

    EQ3/6 geochemical modeling code package was used to investigate the interaction of the Topopah Spring Tuff and J-13 water at high temperatures. EQ3/6 input parameters were obtained from the results of laboratory experiments using USW G-1 core and J-13 water. Laboratory experiments were run at 150 and 250{sup 0}C for 66 days using both wafer-size and crushed tuff. EQ3/6 modeling reproduced results of the 150{sup 0}C experiments except for a small increase in the concentration of potassium that occurs in the first few days of the experiments. At 250{sup 0}C, the EQ3/6 modeling reproduced the major water/rock reactions except for a small increase in potassium, similar to that noted above, and an overall increase in aluminum. The increase in potassium concentration cannot be explained at this time, but the increase in A1 concentration is believed to be caused by the lack of thermodynamic data in the EQ3/6 data base for dachiardite, a zeolite observed as a run product at 250{sup 0}C. The ability to reproduce the majority of the experimental rock/water interactions at 150{sup 0}C validates the use of EQ3/6 as a geochemical modeling tool that can be used to theoretically investigate physical/chemical environments in support of the Waste Package Task of NNWSI.

  15. Responsiveness of the anxiety/depression dimension of the 3- and 5-level versions of the EQ-5D in assessing mental health.

    Science.gov (United States)

    Crick, Katelynn; Al Sayah, Fatima; Ohinmaa, Arto; Johnson, Jeffrey A

    2018-06-01

    Anxiety and depression disorders are associated with significantly lower health-related quality of life (HRQL). The EQ-5D is a commonly used generic measure of HRQL; it captures mental health through a single domain-the anxiety/depression dimension. Evidence on the responsiveness of this measure in assessing changes in mental health changes is limited. To examine the performance of the anxiety/depression dimension (A/D) of the 3- and 5-level (3L and 5L) versions of the EQ-5D in assessing changes in mental health. Data from two patient populations were used: 495 adults post-discharge from general internal medicine ward (EQ-5D-3L), and 225 type 2 diabetes patients who screened positive for depressive symptoms (EQ-5D-5L). Anchor-based approach along with effect sizes (ES) and ROC analysis was used. Anchors included patient health questionnaire 9-items "PHQ9" and generalized anxiety disorder 2-item questionnaire "GAD2" for EQ-5D-3L, and PHQ9 and SF-12 mental composite summary scores (MCS) for EQ-5D-5L. A/D change was quantified as the difference between follow-up and baseline levels. The A/D dimension of the EQ-5D-3L showed limited responsiveness to changes in depressive symptoms measured by PHQ9 and for anxiety symptoms measured by GAD2, whereby in those who improved or deteriorated in either symptom, more than half of the patients did not have an A/D change. In the ROC analysis, the A/D dimension of the EQ-5D-3L showed weak performance with C-indices ranging from 0.58 to 0.63 and probability of detection of depressive or anxiety symptoms ranging between 20 and 40%, which are all well below acceptable ranges. Similar results were observed for the A/D dimension of the EQ-5D-5L; although the performance was slightly better, it was still below acceptable range. In patients who improved or deteriorated based on the PHQ9 or MCS, around a third had no changes on the A/D dimension. The performance of the A/D dimension of the EQ-5D-5L was also very limited with C

  16. Quality of Life Evaluation of Cervical Cancer Inpatients Before and After Chemotherapy by Using the EQ-5D Questionnaire

    Directory of Open Access Journals (Sweden)

    Suwendar

    2017-03-01

    Full Text Available The quality of life is one of success parameters of the treatment effort including chemotherapy in cancer patients. Cancer patients undergoing chemotherapy may experience changes in their quality of life. This study aimed to assess the quality of life of patients with cervical cancer in Indonesia using the EQ‑5D questionnaire pre and post-chemotherapy. The research was an analitycal non-experimental study according to the patient’s perspective using prospective data collection techniques. The research subjects were the patients who suffered from cervical cancer who were hospitalized in class 3 and fullfilled the inclusive requirement. The research was conducted in Dr. Hasan Sadikin Bandung general hospital, from June until December 2015. The study was conducted by the EQ-5D questionnaire. Futhermore, the percentage of the patients’ problems, EQ-5D index (utility and EQ-5D VAS were calculated. Utility and EQ-5D values was analysed statistically using Wilcoxon test (α=5% to determine if there were significant condition changes before and after chemotherapy. The results showed that after the first cycle of chemotherapy, the percentage of patients reporting problem is related to ability to walk/move and the usual activities problem increased, pain/discomfort and anxiety/depression problem decreased, while the self‑care problem did not change. After the first cycle of chemotherapy, the utility and EQ-5D values increased and showed significant improvement (T count value=2.0 and 4.5 respectively in patients with stage I.

  17. EQPT, a data file preprocessor for the EQ3/6 software package: User`s guide and related documentation (Version 7.0); Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Daveler, S.A.; Wolery, T.J.

    1992-12-17

    EQPT is a data file preprocessor for the EQ3/6 software package. EQ3/6 currently contains five primary data files, called datao files. These files comprise alternative data sets. These data files contain both standard state and activity coefficient-related data. Three (com, sup, and nea) support the use of the Davies or B-dot equations for the activity coefficients; the other two (hmw and pit) support the use of Pitzer`s (1973, 1975) equations. The temperature range of the thermodynamic data on these data files varies from 25{degrees}C only to 0-300{degrees}C. The principal modeling codes in EQ3/6, EQ3NR and EQ6, do not read a data0 file, however. Instead, these codes read an unformatted equivalent called a data1 file. EQPT writes a datal file, using the corresponding data0 file as input. In processing a data0 file, EQPT checks the data for common errors, such as unbalanced reactions. It also conducts two kinds of data transformation. Interpolating polynomials are fit to data which are input on temperature adds. The coefficients of these polynomials are then written on the datal file in place of the original temperature grids. A second transformation pertains only to data files tied to Pitzer`s equations. The commonly reported observable Pitzer coefficient parameters are mapped into a set of primitive parameters by means of a set of conventional relations. These primitive form parameters are then written onto the datal file in place of their observable counterparts. Usage of the primitive form parameters makes it easier to evaluate Pitzer`s equations in EQ3NR and EQ6. EQPT and the other codes in the EQ3/6 package are written in FORTRAN 77 and have been developed to run under the UNIX operating system on computers ranging from workstations to supercomputers.

  18. A Head-to-Head Comparison of UK SF-6D and Thai and UK EQ-5D-5L Value Sets in Thai Patients with Chronic Diseases.

    Science.gov (United States)

    Sakthong, Phantipa; Munpan, Wipaporn

    2017-10-01

    Little was known about the head-to-head comparison of psychometric properties between SF-6D and EQ-5D-5L or the different value sets of EQ-5D-5L. Therefore, this study set out to compare the psychometric properties including agreement, convergent, and known-group validity between the SF-6D and the EQ-5D-5L using the real value sets from Thailand and the UK in patients with chronic diseases. 356 adults taking a medication for at least 3 months were identified from a university hospital in Bangkok, Thailand, between July 2014 and March 2015. Agreement was assessed by intraclass correlation coefficients (ICCs) and Bland-Altman plots. Convergent validity was evaluated using Spearman's rank correlation coefficients between SF-6D and EQ-5D-5L and EQ-VAS and SF-12v2. For known-groups validity, the Mann-Whitney U test and Kruskal-Wallis test were used to examine the associations between SF-6D and EQ-5D-5L and patient characteristics. Agreements between the SF-6D and the EQ-5D-5L using Thai and UK value sets were fair, with ICCs of 0.45 and 0.49, respectively. Bland-Altman plots showed that the majority of the SF-6D index scores were lower than the EQ-5D-5L index scores. Both the EQ-5D-5L value sets were more related to the EQ-VAS and physical health, while the SF-6D was more associated with mental health. Both EQ-5D-5L value sets were more sensitive than the SF-6D in discriminating patients with different levels of more known groups except for adverse drug reactions. The SF-6D and both EQ-5D-5L value sets appeared to be valid but sensitive to different outcomes in Thai patients with chronic diseases.

  19. Validation of Ulchin Units 1, 2 CONTEMPT Model Prior to the Production of EQ Envelope Curve

    International Nuclear Information System (INIS)

    Hwang, Su Hyun; Kim, Min Ki; Hong, Soon Joon; Lee, Byung Chul; Suh, Jeong Kwan; Lee, Jae Yong; Song, Dong Soo

    2010-01-01

    The Ulchin Units 1, 2 will be refurbished with RSG (Replacement of Steam Generator) and PU (Power Uprate). The current EQ (Environmental Qualification) envelope curve should be modified according to RSG and PU. The containment P/T (Pressure/Temperature) analysis in Ulchin Units 1, 2 FSAR was done using EDF computer program PAREO6. PAREO6 uses the same assumptions as the US NRC CONTEMPT program, and the results given by both programs are in good agreement. It is utilized to determine pressure and temperature variations in a PWR containment subsequent to a reactor coolant or secondary system pipe break. But PAREO6 cannot be available to the production of EQ envelope curve, so CONTEMPT code should be used instead of PAREO6. It is essential to validate the CONTEMPT OSG (Original Steam Generator) model prior to the production of EQ envelope curve considering RSG and PU. This study has been performed to validate the CONTEMPT model of Ulchin Units 1, 2 by comparing the CONTEMPT results with the PAERO6 results in Ulchin Units 1, 2 FSAR

  20. Validation of Ulchin Units 1, 2 CONTEMPT Model Prior to the Production of EQ Envelope Curve

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Su Hyun; Kim, Min Ki; Hong, Soon Joon; Lee, Byung Chul [FNC Technology Co., SNU, Seoul (Korea, Republic of); Suh, Jeong Kwan; Lee, Jae Yong; Song, Dong Soo [KEPCO Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    The Ulchin Units 1, 2 will be refurbished with RSG (Replacement of Steam Generator) and PU (Power Uprate). The current EQ (Environmental Qualification) envelope curve should be modified according to RSG and PU. The containment P/T (Pressure/Temperature) analysis in Ulchin Units 1, 2 FSAR was done using EDF computer program PAREO6. PAREO6 uses the same assumptions as the US NRC CONTEMPT program, and the results given by both programs are in good agreement. It is utilized to determine pressure and temperature variations in a PWR containment subsequent to a reactor coolant or secondary system pipe break. But PAREO6 cannot be available to the production of EQ envelope curve, so CONTEMPT code should be used instead of PAREO6. It is essential to validate the CONTEMPT OSG (Original Steam Generator) model prior to the production of EQ envelope curve considering RSG and PU. This study has been performed to validate the CONTEMPT model of Ulchin Units 1, 2 by comparing the CONTEMPT results with the PAERO6 results in Ulchin Units 1, 2 FSAR

  1. Membrana amniótica preservada em glicerina no reparo de feridas cutâneas de membros locomotores de eqüinos

    OpenAIRE

    Oliveira,Valdemir Alves de; Alvarenga,José de

    1998-01-01

    Neste estudo experimental, avaliou-se o uso de membrana amniótica eqüina preservada em glicerina 98%, à temperatura ambiente, em feridas com cura por segunda intenção, nos membros locomotores de eqüinos. Foram provocadas cirurgicamente feridas de 9,6cm² na face lateral da articulação metacarpo-falangeana, face medial do terço proximal do metacarpo e face lateral do terço médio do metatarso de ambos os membros locomotores de cinco eqüinos adultos, perfazendo total de trinta feridas. Foram cons...

  2. An Empirical Comparison of the EQ-5D-5L, DEMQOL-U and DEMQOL-Proxy-U in a Post-Hospitalisation Population of Frail Older People Living in Residential Aged Care.

    Science.gov (United States)

    Ratcliffe, Julie; Flint, Thomas; Easton, Tiffany; Killington, Maggie; Cameron, Ian; Davies, Owen; Whitehead, Craig; Kurrle, Susan; Miller, Michelle; Liu, Enwu; Crotty, Maria

    2017-06-01

    To empirically compare the measurement properties of the DEMQOL-U and DEMQOL-Proxy-U instruments to the EQ-5D-5L and its proxy version (CEQ-5D-5L) in a population of frail older people living in residential aged care in the post-hospitalisation period following a hip fracture. A battery of instruments to measure health-related quality of life (HRQoL), cognition, and clinical indicators of depression, pain and functioning were administered at baseline and repeated at 4 weeks' follow-up. Descriptive summary statistics were produced and psychometric analyses were conducted to assess the levels of agreement, convergent validity and known group validity between clinical indicators and HRQoL measures. There was a large divergence in mean (SD) utility scores at baseline for the EQ-5D-5L and DEMQOL-U [EQ-5D-5L mean 0.21 (0.19); DEMQOL-U mean 0.79 (0.14)]. At 4 weeks' follow-up, there was a marked improvement in EQ-5D-5L scores whereas DEMQOL-U scores had deteriorated. [EQ-5D-5L mean 0.45 (0.38); DEMQOL-U mean 0.58 (0.38)]. The EQ-5D and CEQ-5D-5L were more responsive to the physical recovery trajectory experienced by frail older people following surgery to repair a fractured hip, whereas the DEMQOL-U and DEMQOL-Proxy-U appeared more responsive to the changes in delirium and dementia symptoms often experienced by frail older people in this period. This study presents important insights into the HRQoL of a relatively under-researched population of post-hospitalisation frail older people in residential care. Further research should investigate the implications for economic evaluation of self-complete versus proxy assessment of HRQoL and the choice of preference-based instrument for the measurement and valuation of HRQoL in older people exhibiting cognitive decline, dementia and other co-morbidities.

  3. Valores de digestibilidade de alimentos volumosos para eqüinos Values of digestibility of forage feeds for equines

    Directory of Open Access Journals (Sweden)

    Danilo Mariano Figueiredo

    1999-08-01

    Full Text Available Quatro ensaios de metabolismo foram realizados para obter informações sobre os valores de digestibilidade dos nutrientes na alimentação de eqüinos. Cavalos castrados, sem raça definida, com idade média de seis anos de idade foram usados. Nos experimentos foram testados: (1 cana-de-açúcar, (2 combinação de 59,0% de cana-de-açúcar e 41,0% de milho grão inteiro, (3 capim-elefante e (4 cana-de-açúcar com 1,5 % de uréia. O consumo médio de MS foi de 0,89; 1,11; 2,02; e 1,03% PV para cana-de-açúcar, cana-de-açúcar mais milho grão inteiro, capim-elefante e cana-de-açúcar mais uréia, respectivamente. Os valores de energia digestível para cana-de-açúcar, cana-de-açúcar mais milho grão inteiro, cana-de-açúcar mais uréia e capim-elefante foram 2361, 3382, 2060 e 1182 kcal/kg MS, respectivamente. Cana-de-açúcar e cana-de-açúcar mais milho grão inteiro são boas fontes alternativas de alimentos para os eqüinos. O capim-elefante e a adição de 1,5% de uréia a cana-de-açúcar apresentaram menor potencial nutricional como volumoso na alimentação de cavalos adultos.Four metabolism assays were carried out to btain information on the nutrient digestibility of horses feeding. Geldings without definite breed, with average of six years of age, were used. In the experiments were tested: (1 sugar cane; (2 a combination of 59.0% of sugar cane and 41.0% of whole corn grain; (3 elephant grass; (4 and sugar cane with 1.5% of urea. The average DM intake was .89, 1.11, 2.02 and 1.03% LW for sugar cane, sugar cane plus whole corn grain, elephant grass, and sugar cane plus urea, respectively. The values of the digestible energy for sugar cane, sugar cane plus whole corn grain, sugar cane plus urea and elephant grass were 2361, 3382, 2060 and 1182 kcal/kg DM, respectively. The sugar cane and sugar cane plus whole corn grain are good alternative sources of feed for equines. The elephant grass and addition of 1.5% of urea in sugar

  4. Analyzing Health-Related Quality of Life Data to Estimate Parameters for Cost-Effectiveness Models: An Example Using Longitudinal EQ-5D Data from the SHIFT Randomized Controlled Trial.

    Science.gov (United States)

    Griffiths, Alison; Paracha, Noman; Davies, Andrew; Branscombe, Neil; Cowie, Martin R; Sculpher, Mark

    2017-03-01

    The aim of this article is to discuss methods used to analyze health-related quality of life (HRQoL) data from randomized controlled trials (RCTs) for decision analytic models. The analysis presented in this paper was used to provide HRQoL data for the ivabradine health technology assessment (HTA) submission in chronic heart failure. We have used a large, longitudinal EuroQol five-dimension questionnaire (EQ-5D) dataset from the Systolic Heart Failure Treatment with the I f Inhibitor Ivabradine Trial (SHIFT) (clinicaltrials.gov: NCT02441218) to illustrate issues and methods. HRQoL weights (utility values) were estimated from a mixed regression model developed using SHIFT EQ-5D data (n = 5313 patients). The regression model was used to predict HRQoL outcomes according to treatment, patient characteristics, and key clinical outcomes for patients with a heart rate ≥75 bpm. Ivabradine was associated with an HRQoL weight gain of 0.01. HRQoL weights differed according to New York Heart Association (NYHA) class (NYHA I-IV, no hospitalization: standard care 0.82-0.46; ivabradine 0.84-0.47). A reduction in HRQoL weight was associated with hospitalizations within 30 days of an HRQoL assessment visit, with this reduction varying by NYHA class [-0.07 (NYHA I) to -0.21 (NYHA IV)]. The mixed model explained variation in EQ-5D data according to key clinical outcomes and patient characteristics, providing essential information for long-term predictions of patient HRQoL in the cost-effectiveness model. This model was also used to estimate the loss in HRQoL associated with hospitalizations. In SHIFT many hospitalizations did not occur close to EQ-5D visits; hence, any temporary changes in HRQoL associated with such events would not be captured fully in observed RCT evidence, but could be predicted in our cost-effectiveness analysis using the mixed model. Given the large reduction in hospitalizations associated with ivabradine this was an important feature of the analysis. The

  5. Development of a large volume injection method using a programmed temperature vaporization injector - gas chromatography hyphenated to ICP-MS for the simultaneous determination of mercury, tin and lead species at ultra-trace levels in natural waters.

    Science.gov (United States)

    Terán-Baamonde, J; Bouchet, S; Tessier, E; Amouroux, D

    2018-04-27

    The current EU legislation lays down Environmental Quality Standards (EQS) for 45 priority substances in surface waters; among them levels for (organo)metallic species of Hg, Sn and Pb are set between ng L -1 (for Hg and Sn) and μg L -1 (for Pb). To date, only a few analytical methods can reach these very restrictive limits and there is thus a need for comprehensive methods able to analyze these species down to these levels in natural waters. The aim of this work was to develop an online automated pre-concentration method using large volume injections with a Programmed Temperature Vaporization (PTV) injector fitted with a sorbent packed liner coupled to GC-ICP-MS to further improve the detection limits associated to this well-established method. The influence of several parameters such as the PTV transfer temperature and time, carrier gas flow rate and amount of packing material was investigated. Finally, the maximum volume injected through single or multiple injection modes was optimized to obtain the best compromise between chromatographic resolution and sensitivity. After optimization, very satisfactory results in terms of absolute and methodological detection limits were achieved, down to the pg L -1 level for all species studied. The potential of the method was exemplified by determining the concentrations of organometallic compounds in unpolluted river waters samples from the Adour river basin (SW France) and results were compared with conventional (splitless) GC-ICP-MS. The strength of this analytical method lies in the low detection limits reached for the simultaneous analysis of a wide group of organometallic compounds, and the potential to transfer this method to other gas chromatographic applications with inherent lower sensitivity. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Survey of diagnostic and treatment practices for multiple sclerosis (MS) in Europe. Part 2: Progressive MS, paediatric MS, pregnancy and general management.

    Science.gov (United States)

    Fernández, O; Delvecchio, M; Edan, G; Fredrikson, S; Giovannoni, G; Hartung, H-P; Havrdova, E; Kappos, L; Pozzilli, C; Soerensen, P S; Tackenberg, B; Vermersch, P; Comi, G

    2018-05-01

    The European Charcot Foundation supported the development of a set of surveys to understand current practice patterns for the diagnosis and management of multiple sclerosis (MS) in Europe. Part 2 of the report summarizes survey results related to secondary progressive MS (SPMS), primary progressive MS (PPMS), pregnancy, paediatric MS and overall patient management. A steering committee of MS neurologists developed case- and practice-based questions for two sequential surveys distributed to MS neurologists throughout Europe. Respondents generally favoured changing rather than stopping disease-modifying treatment (DMT) in patients transitioning from relapsing-remitting MS to SPMS, particularly with active disease. Respondents would not initiate DMT in patients with typical PPMS symptoms, although the presence of ≥1 spinal cord or brain gadolinium-enhancing lesion might affect that decision. For patients considering pregnancy, respondents were equally divided on whether to stop treatment before or after conception. Respondents strongly favoured starting DMT in paediatric MS with active disease; recommended treatments included interferon, glatiramer acetate and, in John Cunningham virus negative patients, natalizumab. Additional results regarding practice-based questions and management are summarized. Results of part 2 of the survey of diagnostic and treatment practices for MS in Europe largely mirror results for part 1, with neurologists in general agreement about the treatment and management of SPMS, PPMS, pregnancy and paediatric MS as well as the general management of MS. However, there are also many areas of disagreement, indicating the need for evidence-based recommendations and/or guidelines. © 2018 EAN.

  7. Tamuarawai (EQS) : an early lapita site on Emirau, New Ireland, PNG

    International Nuclear Information System (INIS)

    Summerhayes, G.R.; Matisoo-Smith, E.; Mandui, H.; Allen, J.; Specht, J.; Hogg, N.; McPherson, S.

    2010-01-01

    In 2007 a new Early Lapita site called Tamuarawai (EQS) was located on Emirau Island, Papua New Guinea. Two seasons of excavation (2007, 2008) have been undertaken. This paper describes the site and some of the preliminary analyses undertaken. Some unusual results suggest that Tamuarawai will make an important contribution to modelling the Early Lapita occupation of the Bismarck Archipelago. (author). 29 refs., 11 figs., 11 tabs.

  8. Unusual Animal Behavior Preceding the 2011 Earthquake off the Pacific Coast of Tohoku, Japan: A Way to Predict the Approach of Large Earthquakes

    Directory of Open Access Journals (Sweden)

    Hiroyuki Yamauchi

    2014-04-01

    Full Text Available Unusual animal behaviors (UABs have been observed before large earthquakes (EQs, however, their mechanisms are unclear. While information on UABs has been gathered after many EQs, few studies have focused on the ratio of emerged UABs or specific behaviors prior to EQs. On 11 March 2011, an EQ (Mw 9.0 occurred in Japan, which took about twenty thousand lives together with missing and killed persons. We surveyed UABs of pets preceding this EQ using a questionnaire. Additionally, we explored whether dairy cow milk yields varied before this EQ in particular locations. In the results, 236 of 1,259 dog owners and 115 of 703 cat owners observed UABs in their pets, with restless behavior being the most prominent change in both species. Most UABs occurred within one day of the EQ. The UABs showed a precursory relationship with epicentral distance. Interestingly, cow milk yields in a milking facility within 340 km of the epicenter decreased significantly about one week before the EQ. However, cows in facilities farther away showed no significant decreases. Since both the pets’ behavior and the dairy cows’ milk yields were affected prior to the EQ, with careful observation they could contribute to EQ predictions.

  9. Adverse Selection in Community Based Health Insurance among Informal Workers in Bangladesh: An EQ-5D Assessment

    Directory of Open Access Journals (Sweden)

    Sayem Ahmed

    2018-01-01

    Full Text Available Community-based Health Insurance (CBHI schemes are recommended for providing financial risk protection to low-income informal workers in Bangladesh. We assessed the problem of adverse selection in a pilot CBHI scheme in this context. In total, 1292 (646 insured and 646 uninsured respondents were surveyed using the Bengali version of the EuroQuol-5 dimensions (EQ-5D questionnaire for assessing their health status. The EQ-5D scores were estimated using available regional tariffs. Multiple logistic regression was applied for predicting the association between health status and CBHI scheme enrolment. A higher number of insured reported problems in mobility (7.3%; p = 0.002; self-care (7.1%; p = 0.000 and pain and discomfort (7.7%; p = 0.005 than uninsured. The average EQ-5D score was significantly lower among the insured (0.704 compared to the uninsured (0.749. The regression analysis showed that those who had a problem in mobility (m 1.25–2.17; self-care (OR = 2.29; 95% CI: 1.62–3.25 and pain and discomfort (OR = 1.43; 95% CI: 1.13–1.81 were more likely to join the scheme. Individuals with higher EQ-5D scores (OR = 0.46; 95% CI: 0.31–0.69 were less likely to enroll in the scheme. Given that adverse selection was evident in the pilot CBHI scheme, there should be consideration of this problem when planning scale-up of these kind of schemes.

  10. Usefulness of EQ-5D in Assessing Health Status in Primary Care Patients with Major Depressive Disorder

    Directory of Open Access Journals (Sweden)

    Nowicki Marie-Laure

    2004-05-01

    Full Text Available Abstract Objectives Major depressive disorder (MDD is a prevalent psychiatric disorder associated with impaired patient functioning and reductions in health-related quality of life (HRQL. The present study describes the impact of MDD on patients' HRQL and examines preference-based health state differences by patient features and clinical characteristics. Methods 95 French primary care practitioners recruited 250 patients with a DSM-IV diagnosis of MDD for inclusion in an eight-week follow-up cohort. Patient assessments included the Montgomery Asberg Depression Rating Scale (MADRS, the Clinical Global Impression of Severity (CGI, the Short Form-36 Item scale (SF-36, the Quality of Life Depression Scale (QLDS and the EuroQoL (EQ-5D. Results The mean EQ-5D utility at baseline was 0.33, and 8% of patients rated their health state as worse than death. There were no statistically significant differences in utilities by demographic features. Significant differences were found in mean utilities by level of disease severity assessed by CGI. The different clinical response profiles, assessed by MADRS, were also revealed by EQ-5D at endpoint: 0.85 for responders remitters, 0.72 for responders non-remitter, and 0.58 for non-responders. Even if HRQL and EQ-5D were moderately correlated, they shared only 40% of variance between baseline and endpoint. Conclusions Self-reported patient valuations for depression are important patient-reported outcomes for cost-effectiveness evaluations of new antidepressant compounds and help in further understanding patient compliance with antidepressant treatment.

  11. Longitudinal predictive ability of mapping models: examining post-intervention EQ-5D utilities derived from baseline MHAQ data in rheumatoid arthritis patients.

    Science.gov (United States)

    Kontodimopoulos, Nick; Bozios, Panagiotis; Yfantopoulos, John; Niakas, Dimitris

    2013-04-01

    The purpose of this methodological study was to to provide insight into the under-addressed issue of the longitudinal predictive ability of mapping models. Post-intervention predicted and reported utilities were compared, and the effect of disease severity on the observed differences was examined. A cohort of 120 rheumatoid arthritis (RA) patients (60.0% female, mean age 59.0) embarking on therapy with biological agents completed the Modified Health Assessment Questionnaire (MHAQ) and the EQ-5D at baseline, and at 3, 6 and 12 months post-intervention. OLS regression produced a mapping equation to estimate post-intervention EQ-5D utilities from baseline MHAQ data. Predicted and reported utilities were compared with t test, and the prediction error was modeled, using fixed effects, in terms of covariates such as age, gender, time, disease duration, treatment, RF, DAS28 score, predicted and reported EQ-5D. The OLS model (RMSE = 0.207, R(2) = 45.2%) consistently underestimated future utilities, with a mean prediction error of 6.5%. Mean absolute differences between reported and predicted EQ-5D utilities at 3, 6 and 12 months exceeded the typically reported MID of the EQ-5D (0.03). According to the fixed-effects model, time, lower predicted EQ-5D and higher DAS28 scores had a significant impact on prediction errors, which appeared increasingly negative for lower reported EQ-5D scores, i.e., predicted utilities tended to be lower than reported ones in more severe health states. This study builds upon existing research having demonstrated the potential usefulness of mapping disease-specific instruments onto utility measures. The specific issue of longitudinal validity is addressed, as mapping models derived from baseline patients need to be validated on post-therapy samples. The underestimation of post-treatment utilities in the present study, at least in more severe patients, warrants further research before it is prudent to conduct cost-utility analyses in the context

  12. Characterization of a Full-Length Endogenous Beta-Retrovirus, EqERV-Beta1, in the Genome of the Horse (Equus caballus

    Directory of Open Access Journals (Sweden)

    Antoinette C. van der Kuyl

    2011-06-01

    Full Text Available Information on endogenous retroviruses fixed in the horse (Equus caballus genome is scarce. The recent availability of a draft sequence of the horse genome enables the detection of such integrated viruses by similarity search. Using translated nucleotide fragments from gamma-, beta-, and delta-retroviral genera for initial searches, a full-length beta-retrovirus genome was retrieved from a horse chromosome 5 contig. The provirus, tentatively named EqERV-beta1 (for the first equine endogenous beta-retrovirus, was 10434 nucleotide (nt in length with the usual retroviral genome structure of 5’LTR-gag-pro-pol-env-3’LTR. The LTRs were 1361 nt long, and differed approximately 1% from each other, suggestive of a relatively recent integration. Coding sequences for gag, pro and pol were present in three different reading-frames, as common for beta-retroviruses, and the reading frames were completely open, except that the env gene was interrupted by a single stopcodon. No reading frame was apparent downstream of the env gene, suggesting that EqERV-beta1 does not encode a superantigen like mouse mammary tumor virus (MMTV. A second proviral genome of EqERV-beta1, with no stopcodon in env, is additionally integrated on chromosome 5 downstream of the first virus. Single EqERV-beta1 LTRs were abundantly present on all chromosomes except chromosome 24. Phylogenetically, EqERV-beta1 most closely resembles an unclassified retroviral sequence from cattle (Bos taurus, and the murine beta-retrovirus MMTV.

  13. Spanish Adaptation and Validation of the Transplant Effects Questionnaire (TxEQ-Spanish in Liver Transplant Recipients and Its Relationship to Posttraumatic Growth and Quality of Life

    Directory of Open Access Journals (Sweden)

    María Á. Pérez-San-Gregorio

    2018-04-01

    Full Text Available The valid assessment of the impact of transplantation on psychological well-being is highly relevant to optimize treatment. However, to date there is no standardized instrument available in Spain. The Transplant Effects Questionnaire (TxEQ evaluates the specific problems associated with organ transplantation, such as worry about transplant, guilt regarding the donor, disclosure of having undergone transplantation, adherence to medical treatment and responsibility toward the donor, family, friends, or medical staff. Against this backdrop the English original version of the TxEQ was translated into Spanish and validated in a sample of 240 liver transplant recipients. Participants also filled in the Posttraumatic Growth Inventory (PTGI, and the 12-Item Short Form Health Survey (SF-12v.2. Confirmatory factor analysis of the TxEQ-Spanish revealed a five-factor structure equivalent to the English original version, and satisfactory internal consistency (Cronbach's alpha: worry α = 0.82, guilt α = 0.77, disclosure α = 0.91, adherence α = 0.82, responsibility α = 0.83. Results showed that better mental quality of life was associated with higher adherence and disclosure, as well as less worry and guilt. Higher posttraumatic growth was significantly associated with worry, guilt, and responsibility. Interestingly, the most powerful predictor of posttraumatic growth was worry. Analysis of variance showed an interaction effect of PTG and mental quality of life on adherence, with medium PTG being associated with significantly stronger adherence in participants with better mental quality of life. In conclusion our study could successfully adapt and validate the Spanish version of the TxEQ in a large sample of liver transplant recipients. Our findings show a complex relationship between emotional reactions to transplantation, mental quality of life, and posttraumatic growth, which give further insight into inner processes supporting psychological well

  14. Level of agreement between patient and proxy responses to the EQ-5D health questionnaire 12 months after injury.

    Science.gov (United States)

    Gabbe, Belinda J; Lyons, Ronan A; Sutherland, Ann M; Hart, Melissa J; Cameron, Peter A

    2012-04-01

    Health-related quality of life represents a patient's experiences and expectations and should be collected from the patient. In trauma, collection of information from the patient can be challenging, particularly for subgroups where cognitive impairment is prevalent, increasing reliance on proxy reporting. This study assessed the agreement between patient and proxy reporting of health-related quality of life 12 months after injury. The Victorian State Trauma Registry and Victorian Orthopaedic Trauma Outcomes Registry collect EQ-5D data at 12 months after injury. Cases where data were collected from the patient and proxy were extracted. Agreement between patient and proxy responses was compared using kappa (K) coefficients for the individual EQ-5D items, and Bland-Altman plots and Wilcoxon signed-rank tests for the EQ-5D summary score and visual analog scale (VAS). Agreement between patient and proxy respondents was substantial for the mobility (K = 0.61) and personal care items (K = 0.67) and moderate for the usual activities (K = 0.50), pain/discomfort (K = 0.42), and anxiety/depression items (K = 0.47). The mean difference between proxy and patient-reported scores for the VAS (0.74, 95% confidence interval: -2.73, 4.21) and the EQ-5D summary score (-0.02, 95% confidence interval: -0.07, 0.03) was small, but the limits of agreement were wide (-34.22 to 35.71 for VAS and -0.55 to 0.51 for summary score), suggesting no systematic bias. Although proxy and patient responses for the EQ-5D VAS may differ, the differences show random variability rather than systematic bias. Group comparisons using proxy responses are unlikely to be biased, but proxy responses should be used with caution when assessing individual patient recovery.

  15. PENGEMBANGAN BAHAN AJAR MATEMATIKA DENGAN PENDEKATAN KONTEKSTUAL DAN METODE PENEMUAN TERBIMBING UNTUK MENINGKATKAN EQ DAN SQ SISWA SMP AKSELERASI

    Directory of Open Access Journals (Sweden)

    Yhasinta Agustyarini

    2015-05-01

    DEVELOPING MATHEMATICS INSTRUCTIONAL MATERIAL USINGCONTEXTUAL APPROACH AND GUIDED INQUIRY METHOD TO INCREASE EQ AND SQ OF ACCELERATION STUDENTS IN JUNIOR HIGH SCHOOL Abstract This research is aimed to describe steps of developing mathematics instructional material using contextual approach and guided inquiry method and describe the quality of the developed product. This research is a developmental research with the main steps cover (1 preliminary investigation, (2 design, (3 realization/construction, (4 test, evaluation, and revision, and (5 implementation. The result of validation by expert jugdement shows that the instructional material that is developed is of valid criteria of very good category. The aspects of practicality was of practice criteria of very good category as seen from the implementation of the learning, evaluation by the teachers, and evaluation by the students. The aspect of effectiveness could be reached from the students’ achievement and EQ and SQ questionnaire. The result of the test shows that more than 80% of the student achieve the minimum score and percentage many of students who are at a high minimum and very high minimum category increase on EQ and SQ questionnaire. The research produced mathematics instructional material and supporting components, consisting of valid, practical, and effective syllabuses, lesson plans, mathematics module, and the valid, practical, and reliable of test. Keywords: development, instructional material, contextual approach, guided inquiry, EQ, SQ, acceleration

  16. Evaluating the discriminatory power of EQ-5D, HUI2 and HUI3 in a US general population survey using Shannon's indices

    NARCIS (Netherlands)

    Janssen, Mathieu F. Bas; Birnie, Erwin; Bonsel, Gouke J.

    2007-01-01

    OBJECTIVES: To compare quantitatively the discriminatory power of the EQ-5D, HUI2 and HUI3 in terms of absolute and relative informativity, using Shannon's indices. METHODS: EQ-5D and HUI2/3 data completed by a sample of the general adult US population (N = 3,691) were used. Five dimensions allowed

  17. Edentulism and dental prostheses in the elderly: impact on quality of life measured with EuroQol--visual analog scale (EQ-VAS).

    Science.gov (United States)

    Cano-Gutiérrez, Carlos; Borda, Miguel G; Arciniegas, Antonio J; Borda, Claudia X

    2015-01-01

    The objective of this study was to measure the impact of edentulism and dental prostheses on quality of life (QOL) in older adults in Bogota, Colombia. Edentulism is a frequent condition in older adults and has great impact on their QOL. No epidemiological data are currently available on edentulism among older adults in Colombia. Data were obtained from the SABE-Bogota study, a cross-sectional study conducted in 2012, and used to analyze the EQ-VAS (Visual Analog Scale) from the EuroQol instrument to measure the perception of quality of life (QOL) in relation to edentulism. The study included 2,000 individuals over 60 years old. The Spearman-Rho correlation was used to analyze the correlation between EQ-VAS and edentulism. Chi-Square, ANOVA and t-test were used to study the differences in EQ-VAS scores between edentulous and healthy subjects. Statistical significance was set at peducation were related to edentulism. Individuals with fewer teeth and dental prostheses had lower EQ-VAS scores (pmeasuring the perception of QOL in dental health scenarios. Edentulism significantly affects QOL in older adults and the use of dental prosthesis does not improve the perception of QOL.

  18. Sulphur fertilization influences the sulphur species composition in Allium sativum: sulphomics using HPLC-ICPMS/MS-ESI-MS/MS.

    Science.gov (United States)

    Raab, Andrea; Ronzan, Marilena; Feldmann, Joerg

    2017-10-18

    Garlic (A. sativum) contains a large number of small sulphur (S)-containing metabolites, which are important for its taste and smell and vary with A. sativum variety and growth conditions. This study was designed to investigate the influence of different sulphur-fertilization regimes on low molecular weight S-species by attempting the first sulphur mass balance in A. sativum roots and bulbs using HPLC-ICPMS/MS-ESI-MS/MS. Species unspecific quantification of acid soluble S-containing metabolites was achieved using HPLC-ICP-MS/MS. For identification of the compounds, high resolution ESI-MS (Orbitrap LTQ and q-TOF) was used. The plants contained up to 54 separated sulphur-containing compounds, which constitute about 80% of the total sulphur present in A. sativum. The roots and bulbs of A. sativum contained the same compounds, but not necessarily the same amounts and proportions. The S-containing metabolites in the roots reacted more sensitively to manipulations of sulphur fertilization than those compounds in the bulbs. In addition to known compounds (e.g. γ-glutamyl-S-1-propenylcysteine) we were able to identify and partially quantify 31 compounds. Three as yet undescribed S-containing compounds were also identified and quantified for the first time. Putative structures were assigned to the oxidised forms of S-1-propenylmercaptoglutathione, S-2-propenylmercaptoglutathione, S-allyl/propenyl-containing PC-2 and 2-amino-3-[(2-carboxypropyl)sulfanyl]propanoic acid. The parallel use of ICP-MS/MS as a sulphur-specific detector and ESI-MS as a molecular detector simplifies the identification and quantification of sulphur containing metabolites without species specific standards. This non-target analysis approach enables a mass balance approach and identifies the occurrence of the so far unidentified organosulphur compounds. The experiments showed that the sulphur-fertilization regime does not influence sulphur-speciation, but the concentration of some S

  19. Assessing quality of life in children and adolescents: development and validation of the Italian version of the EQ-5D-Y

    Directory of Open Access Journals (Sweden)

    Luciana Scalone

    2011-12-01

    Full Text Available

    Background: Although assessment of Health Related Quality of Life (HRQoL in paediatric populations is gaining interest, it is not sufficiently assessed. While a number of specific paediatric instruments have been developed, some users appear to prefer generic tools such as the EQ-5D, which is a widely used and recommended tool to describe and value health across many different adult populations. We adapted the EQ-5D generic instrument into the EQ-5D-Y(youth for the assessment of HRQoL in children and adolescents, and investigated the feasibility, acceptability, validity and reliability of this new version of the tool.

    Methods: The Italian version of the EQ-5D-Y was administered to 415 children and adolescents from a general population aged between 8 and 15, and to 25 paediatric patients diagnosed with Acute Lymphoblastic Leukaemia (ALL.

    Results: The Italian version of the EQ-5D-Y was found to be feasible and acceptable for self-completion in the target age-group, with less than 1% refusing to complete it and no invalid answers given. Convergent and divergent validity tested with a child specific standard instrument was satisfactory overall. The test-retest reliability was moderate to good in all the domains of the descriptive system, and the Visual Analogue Scale (VAS showed optimal levels of reliability (Intraclass Correlation Coefficient = 0.82. As regards known-group validity, compared with the youths from general population, the ALL patients reported more difficulties in four of the five domains of the descriptive system and, on average, had a lower VAS score.

    Conclusions:The Italian version of the EQ-5D-Y shows to be a promising tool for assessing HRQoL in children and adolescents from 8 to 15 years of age. Future studies should further investigate and optimize its applicability to clinical research and carry out economic evaluations within the health

  20. Inequalities in health status among rural residents: EQ-5D findings from household survey China.

    Science.gov (United States)

    Li, Haitao; Wei, Xiaolin; Ma, Aixia; Chung, Roger Y

    2014-05-19

    This study analyzed inequalities in health status among different socioeconomic and demographic rural residents covered by the New Rural Cooperative Medical System in China. A cross-sectional study was conducted in Lian Yungang City, China. A total of 337 respondents, who were selected by using a multistage stratified systematic random sampling method, completed the surveys. A questionnaire consisting of EQ-5D and demographic and socioeconomic information was adopted for data collection, and was administered by face-to-face interviews. Multiple regression models were employed to examine the differences in the Visual Analogue Scale (VAS) score and the EQ-5D dimensions. Compared with those with lower education attainment, the respondents with higher education levels tended to report a higher VAS score (β = 2.666, 95% CI: 0.978 to 6.310), and were less likely to suffer from pain/discomfort (OR = 3.968; 95% CI: 1.447 to 10.880). The singles were more likely than the married to report moderate or extreme problems in usual activities (OR = 4.583; 95% CI: 1.188 to 17.676) and mobility (OR = 10.666; 95% CI: 2.464 to 6.171). However, no statistically significant differences were identified between the respondents with different income levels in the VAS score and EQ-5D dimensions. This study suggests that the singles and the people with lower education levels are high-risk groups for poorer health status in the Chinese rural population. The findings from this study warrant further investigation.

  1. LLNL Yucca Mountain project - near-field environment characterization technical area: Letter report: EQ3/6 version 8: differences from version 7

    Energy Technology Data Exchange (ETDEWEB)

    Wolery, T.J.

    1994-09-29

    EQ3/6 is a software package for geochemical modeling of aqueous systems, such as water/rock or waste/water rock. It is being developed for a variety of applications in geochemical studies for the Yucca Mountain Site Characterization Project. The software has been extensively rewritten for Version 8. The source code has been extensively modernized. The software is now written in Fortran 77 with the most common extensions that are part of the new Fortran 90 standard. The architecture of the software has been improved for better performance and to allow the incorporation of new functional capabilities in Version 8 and planned subsequent versions. In particular, the structure of the major data arrays has been significantly altered and extended. Three new major functional capabilities have been incorporated in Version 8. The first of these allows the treatment of redox disequilibrium in reaction-path modeling. This is a natural extension of the long-running capability of providing for such disequilibrium in static speciation-solubility calculations. Such a capability is important, for example, when dealing with systems containing organic species and certain dissolved gas species. The user defines (and sets the controls for) the components in disequilibrium. Such corrections can now be made if the requisite data are present on a supporting data file. At present, this capability is supported only by the SHV data file, which is based on SUPCRT92. Equilibrium constants and other thermodynamic quantities are correct1961ed for pressures which lie off a standard curve, which is defined on the supporting data file and ordinarily corresponds to 1.013 bar up to IOOC, and the steam/liquid water equilibrium pressure up to 300C. The third new major capability is generic ion exchange option previously developed in prototype in a branch Version 7 level version of EQ3/6 by Brian Viani, Bill Bourcier, and Carol Bruton. This option has been modified to fit into the Version 8 data

  2. An in silico MS/MS library for automatic annotation of novel FAHFA lipids.

    Science.gov (United States)

    Ma, Yan; Kind, Tobias; Vaniya, Arpana; Gennity, Ingrid; Fahrmann, Johannes F; Fiehn, Oliver

    2015-01-01

    A new lipid class named 'fatty acid esters of hydroxyl fatty acids' (FAHFA) was recently discovered in mammalian adipose tissue and in blood plasma and some FAHFAs were found to be associated with type 2 diabetes. To facilitate the automatic annotation of FAHFAs in biological specimens, a tandem mass spectra (MS/MS) library is needed. Due to the limitation of the commercial available standard compounds, we proposed building an in silico MS/MS library to extend the coverage of molecules. We developed a computer-generated library with 3267 tandem mass spectra (MS/MS) for 1089 FAHFA species. FAHFA spectra were generated based on authentic standards with negative mode electrospray ionization and 10, 20, and 40 V collision induced dissociation at 4 spectra/s as used in in ultra-high performance liquid chromatography-QTOF mass spectrometry studies. However, positional information of the hydroxyl group is only obtained either at lower QTOF spectra acquisition rates of 1 spectrum/s or at the MS(3) level in ion trap instruments. Therefore, an additional set of 4290 fragment-rich MS/MS spectra was created to enable distinguishing positional FAHFA isomers. The library was generated based on ion fragmentations and ion intensities of FAHFA external reference standards, developing a heuristic model for fragmentation rules and extending these rules to large swaths of computer-generated structures of FAHFAs with varying chain lengths, degrees of unsaturation and hydroxyl group positions. Subsequently, we validated the new in silico library by discovering several new FAHFA species in egg yolk, showing that this library enables high-throughput screening of FAHFA lipids in various biological matrices. The developed library and templates are freely available for commercial or noncommercial use at http://fiehnlab.ucdavis.edu/staff/yanma/fahfa-lipid-library. This in silico MS/MS library allows users to annotate FAHFAs from accurate mass tandem mass spectra in an easy and fast manner

  3. Spearmint R2R3-MYB transcription factor MsMYB negatively regulates monoterpene production and suppresses the expression of geranyl diphosphate synthase large subunit (MsGPPS.LSU).

    Science.gov (United States)

    Reddy, Vaishnavi Amarr; Wang, Qian; Dhar, Niha; Kumar, Nadimuthu; Venkatesh, Prasanna Nori; Rajan, Chakravarthy; Panicker, Deepa; Sridhar, Vishweshwaran; Mao, Hui-Zhu; Sarojam, Rajani

    2017-09-01

    Many aromatic plants, such as spearmint, produce valuable essential oils in specialized structures called peltate glandular trichomes (PGTs). Understanding the regulatory mechanisms behind the production of these important secondary metabolites will help design new approaches to engineer them. Here, we identified a PGT-specific R2R3-MYB gene, MsMYB, from comparative RNA-Seq data of spearmint and functionally characterized it. Analysis of MsMYB-RNAi transgenic lines showed increased levels of monoterpenes, and MsMYB-overexpressing lines exhibited decreased levels of monoterpenes. These results suggest that MsMYB is a novel negative regulator of monoterpene biosynthesis. Ectopic expression of MsMYB, in sweet basil and tobacco, perturbed sesquiterpene- and diterpene-derived metabolite production. In addition, we found that MsMYB binds to cis-elements of MsGPPS.LSU and suppresses its expression. Phylogenetic analysis placed MsMYB in subgroup 7 of R2R3-MYBs whose members govern phenylpropanoid pathway and are regulated by miR858. Analysis of transgenic lines showed that MsMYB is more specific to terpene biosynthesis as it did not affect metabolites derived from phenylpropanoid pathway. Further, our results indicate that MsMYB is probably not regulated by miR858, like other members of subgroup 7. © 2017 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.

  4. Mormo em eqüídeos nos Estados de Pernambuco e Alagoas

    Directory of Open Access Journals (Sweden)

    Mota Rinaldo A.

    2000-01-01

    Full Text Available Com base em aspectos clínico-patológicos, epidemiológicos e sorológicos, bem como pelo isolamento de Burkholderia mallei, diagnosticaram-se focos de mormo em eqüídeos na Zona da Mata dos Estados de Pernambuco e Alagoas. Clinicamente observaram-se hipertermia, respiração ruidosa, inapetência, emagrecimento progressivo até caquexia, congestão nasal e descarga mucopurulenta, erosões, úlceras e cicatrizes na mucosa nasal. Os linfonodos mandibulares e cervicais superficiais apresentavam-se aumentados de volume, com abscessos e fístulas exsudando material purulento. Na pele, ao longo dos vasos linfáticos, havia formação de nódulos firmes e abscessos que, nos casos crônicos, fistulavam e ulceravam deixando cicatrizes estrelares. A histopatologia dos nódulos de diversos sítios, tanto dos eqüídeos como dos cobaios utilizados na prova de Straus, revelou lesões granulomatosas e piogranulomas. Os dados deste estudo evidenciam a emergência da doença nesta área e permitem recomendar inquéritos soro-epidemiológicos nos Estados de ocorrência dos surtos e nos Estados limítrofes.

  5. Validation and comparison of EuroQoL-5 dimension (EQ-5D) and Short Form-6 dimension (SF-6D) among stable angina patients.

    Science.gov (United States)

    Wu, Jing; Han, Yuerong; Zhao, Fei-Li; Zhou, Jin; Chen, Zhijun; Sun, He

    2014-10-25

    Several preference-based health-related quality of life (HRQoL) instruments have been published and widely used in different populations. However no consensus has emerged regarding the most appropriate instrument in therapeutic area of stable angina. This study compared and validated the psychometric properties of two generic preference-based instruments, the EQ-5D and SF-6D, among Chinese stable angina patients. Convergent validity of the EQ-5D and SF-6D was examined with eight a priori hypotheses from stable angina patients in conjunction with Seattle Angina Questionnaire (SAQ). Responsiveness was compared using the effect size (ES), relative efficiency (RE) and receiver operating characteristic (ROC) curves. Agreement between the EQ-5D and SF-6D was tested using intra-class correlation coefficient (ICC) and Bland-Altman plot. Factors affecting utility difference were explored with multiple linear regression analysis. In 411 patients (mean age 68.08 ± 11.35), mean utility scores (SD) were 0.78 (0.15) for the EQ-5D and 0.68 (0.12) for the SF-6D. Validity was demonstrated by the moderate to strong correlation coefficients (Range: 0.368-0.594, Pstable-angina-specific health status than the EQ-5D (ES: 0.426 to 1.126). RE suggested that the SF-6D (RE: 44.8 to 177.8%) was more efficient than the EQ-5D except for physical function. Poor agreement between them was observed with ICC (0.448, Pstable angina patients. The SF-6D may be a more effective tool with lower ceiling effect and greater sensitivity. Further study is needed to compare other properties, such as reliability and longitudinal response.

  6. A cross-sectional assessment of health-related quality of life in Chinese patients with chronic hepatitis c virus infection with EQ-5D.

    Science.gov (United States)

    Huang, Rui; Rao, Huiying; Shang, Jia; Chen, Hong; Li, Jun; Xie, Qing; Gao, Zhiliang; Wang, Lei; Wei, Jia; Jiang, Jianning; Sun, Jian; Jiang, Jiaji; Wei, Lai

    2018-06-15

    Hepatitis C virus (HCV) infection is one of the most common liver infections, with a decrement in HRQoL of HCV patients. This study aims to assess Health-related quality of life (HRQoL) in Chinese patients with chronic HCV infection, and to identify significant predictors of the HRQoL in these patients of China. In this cross-sectional observational study, treatment-naïve Han ethnic adults with chronic HCV infection were enrolled. Adopting European Quality of Life scale (EQ-5D) and EuroQOL visual analogue scale (EQ-VAS) were used to qualify HRQoL. Results were reported in descriptive analyses to describe sociodemographic and clinical characteristics. Multiple linear regression analysis was applied to investigate the associations of these variables with HRQoL. Binary logistic regression analysis was performed to identify associations of these variables with HRQoL by dimensions of EQ-5D. Nine hundred ninety-seven patients were enrolled in the study [median age 46.0 (37.0, 56.0) years; male 54.8%]. Mean EQ-5D index and EQ-VAS score were 0.780 ± 0.083 and 77.2 ± 14.8. Multiple Linear regression analysis showed that income (< 2000 RMB, β = - 0.134; 2000-4999 RMB, β = - 0.085), moderate or severe symptoms of discomfort (more than one symptoms, β = - 0.090), disease profile (cirrhosis, β = - 0.114), hyperlipidemia (β = - 0.065) and depression (β = - 0.065) were independently associated with EQ-5D index. Residence (the west, β = 0.087), income (< 2000 RMB, β = - 0.129; 2000-4999 RMB, β = - 0.052), moderate or severe symptoms of discomfort (more than one symptoms, β = - 0.091), disease profile and depression (β = - 0.316) were the influencing factors on EQ-VAS. Binary logistic regression indicated that disease profile and clinical depression were the major influencing factors on all five dimensions of EQ-5D. In this cross-sectional assessment of HCV patients in China, we indicated HRQo

  7. The time to trade-off method versus the EQ-5D index to determine health utility in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Dmitriy Vladimirovich Goryachev

    2010-01-01

    The values of the utility index calculated by TTO failed to correlate with those of HAQ and EQ-5D. The disease duration was unrelated to the values of the utility index calculated by any of the methods used. The association of TTO index was found only for VAS-GH "thermometer". Conclusion. EQ-5D index and VAS-GH are the methods of choice in determining health utility for a clinicoeconomic analysis in patients with RA.

  8. EQ3/6 geochemical modeling task plan for Nevada Nuclear Waste Storage Investigations (NNWSI)

    Energy Technology Data Exchange (ETDEWEB)

    Isherwood, D.; Wolery, T.

    1984-04-10

    This task plan outlines work needed to upgrade the EQ3/6 geochemical code and expand the supporting data bases to allow the Nevada Nuclear Waste Storage Investigations (NNWSI) to model chemical processes important to the storage of nuclear waste in a tuff repository in the unsaturated zone. The plan covers the fiscal years 1984 to 1988. The scope of work includes the development of sub-models in the EQ3/6 code package for studying the effects of sorption, precipitation kinetics, redox disequilibrium, and radiolysis on radionuclide speciation and solubility. The work also includes a glass/water interactions model and a geochemical flow model which will allow us to study waste form leaching and reactions involving the waste package. A special emphasis is placed on verification of new capabilities as they are developed and code documentation to meet NRC requirements. Data base expansion includes the addition of elements and associated aqueous species and solid phases that are specific to nuclear waste (e.g., actinides and fission products) and the upgrading and documentation of the thermodynamic data for other species of interest.

  9. SWATH Mass Spectrometry Performance Using Extended Peptide MS/MS Assay Libraries*

    Science.gov (United States)

    Wu, Jemma X.; Song, Xiaomin; Pascovici, Dana; Zaw, Thiri; Care, Natasha; Krisp, Christoph; Molloy, Mark P.

    2016-01-01

    The use of data-independent acquisition methods such as SWATH for mass spectrometry based proteomics is usually performed with peptide MS/MS assay libraries which enable identification and quantitation of peptide peak areas. Reference assay libraries can be generated locally through information dependent acquisition, or obtained from community data repositories for commonly studied organisms. However, there have been no studies performed to systematically evaluate how locally generated or repository-based assay libraries affect SWATH performance for proteomic studies. To undertake this analysis, we developed a software workflow, SwathXtend, which generates extended peptide assay libraries by integration with a local seed library and delivers statistical analysis of SWATH-quantitative comparisons. We designed test samples using peptides from a yeast extract spiked into peptides from human K562 cell lysates at three different ratios to simulate protein abundance change comparisons. SWATH-MS performance was assessed using local and external assay libraries of varying complexities and proteome compositions. These experiments demonstrated that local seed libraries integrated with external assay libraries achieve better performance than local assay libraries alone, in terms of the number of identified peptides and proteins and the specificity to detect differentially abundant proteins. Our findings show that the performance of extended assay libraries is influenced by the MS/MS feature similarity of the seed and external libraries, while statistical analysis using multiple testing corrections increases the statistical rigor needed when searching against large extended assay libraries. PMID:27161445

  10. Comparing the standard EQ-5D three-level system with a five-level version

    NARCIS (Netherlands)

    Janssen, Mathieu F.; Birnie, Erwin; Haagsma, Juanita A.; Bonsel, Gouke J.

    2008-01-01

    OBJECTIVES: The aim of this study is a head-to-head comparison of the performance of the three-level EQ-5D (3L) and a newly developed five-level version (5L). METHODS: Eighty-two respondents valued 15 standardized disease descriptions and their own health on three response scales (3L, 5L, and visual

  11. Complex mixture analysis of peptides using LC/LC-MS/MS and data-dependent protein identification

    International Nuclear Information System (INIS)

    Wasinger, V.; Corthals, G.

    2001-01-01

    The comprehensive identification of proteins within complex solutions by mass-spectrometry largely depends on the sensitivity, resolving power and sampling efficiency of the technology. An integrated orthogonal approach using Strong Cation Exchange-Reverse Phase-MS/MS (SCX-RP-MS/MS) was used to evaluate the data-dependent Collision Induced Dissociation (CID) of yeast peptides. Reverse phase gradient times of 4, 10. 30, 90, and 180 minutes allowed the identification of hundreds of proteins in a nearly automated fashion from nuclear, membrane, and cytosolic distributions. Many proteins from typically difficult to resolve regions of two-dimensional gels, such as >100kDa, > pI 9.0 and Codon Adaptation Index < 0.2, were also identified using this multi-dimensional separation technology. Few low mass proteins (<10kDa) were identified. The impact of scan-range and duty-cycle on CID of peptides will be discussed

  12. Health utility scores from EQ-5D and health-related quality of life in patients with esophageal cancer: a real-world cross-sectional study.

    Science.gov (United States)

    Doherty, M K; Leung, Y; Su, J; Naik, H; Patel, D; Eng, L; Kong, Q Q; Mohsin, F; Brown, M C; Espin-Garcia, O; Vennettilli, A; Renouf, D J; Faluyi, O O; Knox, J J; MacKay, H; Wong, R; Howell, D; Mittmann, N; Darling, G E; Cella, D; Xu, W; Liu, G

    2018-06-14

    Esophageal cancer and its treatment can cause serious morbidity/toxicity. These effects on health-related quality of life (HRQOL) can be measured using disease-specific scales such as FACT-E, generic scales such as EQ-5D-3L, or through symptoms. In a two-year cross-sectional study, we compared HRQOL across esophageal cancer patients treated in an ambulatory clinic and across multiple disease states, among patients with all stages of esophageal cancer. Consenting patients completed FACT-E, EQ-5D, a visual analog scale, and patient reported (PR)-ECOG. Symptom complexes were constructed from FACT-E domains. Responses were categorized by disease state: pre-, during, and post-treatment, surveillance, progression, and palliative chemotherapy. Spearman correlation and multivariable linear regression characterized these associations. In total, 199 patients completed 317 questionnaires. Mean FACT-E and subscale scores dropped from baseline through treatment and recovered during post-treatment surveillance (P < 0.001); EQ-5D health utility scores (HUS) displayed a similar pattern but with smaller differences (P = 0.07), and with evidence of ceiling effect. Among patients with stage II/III esophageal cancer, mean EQ-5D HUS varied across disease states (P < 0.001), along with FACT-E and subscales (P < 0.001). Among patients with advanced disease, there was no significant difference between baseline and on-treatment total scores, but improved esophageal cancer-specific scales were noted (P = 0.003). Strong correlation was observed between EQ-5D and FACT-E (R = 0.73), along with physical and functional subscales. In addition, the association between FACT-E and EQ-5D HUS was maintained in a multivariable model (P < 0.001). We interpret these results to suggest that in a real-world clinic setting, FACT-E, EQ-5D HUS, and symptoms were strongly correlated. Most HRQOL and symptom parameters suggested that patients had worse HRQOL and symptoms during curative therapy

  13. An Australian discrete choice experiment to value eq-5d health states.

    Science.gov (United States)

    Viney, Rosalie; Norman, Richard; Brazier, John; Cronin, Paula; King, Madeleine T; Ratcliffe, Julie; Street, Deborah

    2014-06-01

    Conventionally, generic quality-of-life health states, defined within multi-attribute utility instruments, have been valued using a Standard Gamble or a Time Trade-Off. Both are grounded in expected utility theory but impose strong assumptions about the form of the utility function. Preference elicitation tasks for both are complicated, limiting the number of health states that each respondent can value and, therefore, that can be valued overall. The usual approach has been to value a set of the possible health states and impute values for the remainder. Discrete Choice Experiments (DCEs) offer an attractive alternative, allowing investigation of more flexible specifications of the utility function and greater coverage of the response surface. We designed a DCE to obtain values for EQ-5D health states and implemented it in an Australia-representative online panel (n = 1,031). A range of specifications investigating non-linear preferences with respect to time and interactions between EQ-5D levels were estimated using a random-effects probit model. The results provide empirical support for a flexible utility function, including at least some two-factor interactions. We then constructed a preference index such that full health and death were valued at 1 and 0, respectively, to provide a DCE-based algorithm for Australian cost-utility analyses. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Gas Chromatography (GC) – Mass Spectrometry (MS) analysis of ...

    African Journals Online (AJOL)

    MS. Glycosides, phenolics and alkaloids were indicated in large amount; eugenols and terpenes were also present while saponin, tannins and steroid were absent. Major components detected by GC-MS were 2-Hydroxy hexadecanoic acid ...

  15. The potential use of complex derivatization procedures in comprehensive HPLC-MS/MS detection of anabolic steroids.

    Science.gov (United States)

    Baranov, Pavel A; Appolonova, Svetlana A; Rodchenkov, Grigory M

    2010-10-01

    The use of two separate derivatization procedures with the formation of oxime (hydroxyl ammonium pretreatment) and picolinoyl (mixed anhydride method) derivates of anabolic steroids following HPLC-MS/MS analysis was proposed. The main product ions of obtained derivatives for 21 anabolic steroids were evaluated and fragmentation pathways were compared.The analysis of MS/MS spectra for underivatized steroids versus oxime or picolinoyl derivatives showed that in case of analytes containing conjugated double bonds in sterane core all of the observed MS/MS spectra contained abundant product ions of diagnostic value. The implementation of derivatization procedures to such compounds is useful for upgrading sensitivity or selectivity of the evaluated method. On the other hand, MS/MS spectra of underivatized and oxime analytes without conjugated double bonds in sterane core produce spectra with large amounts of low abundant product ions. Picolinoyl derivatives formation leads to highly specific spectra with product ions of diagnostic value coupled with sensitive and selective analysis at the same time. The intra- and inter-group comparison analysis revealed that fragmentation pathways for underivatized steroids and correspondent oxime derivatives are similar.The obtained oxime and picolinoyl derivatives provided 10-15 times higher ESI response in the HPLC-ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in positive HPLC-ESI-MS mode.Due to the laborious sample preparation we suggest to use the performed strategy for confirmation analysis purposes, metabolic studies or while the identification of new steroids or steroid-like substances. Copyright © 2010 John Wiley & Sons, Ltd.

  16. Interpretation and use of the 5-level EQ-5D response labels varied with survey language among Asians in Singapore.

    Science.gov (United States)

    Luo, Nan; Wang, Ye; How, Choon How; Tay, Ee Guan; Thumboo, Julian; Herdman, Michael

    2015-10-01

    This study aimed to investigate the comparability of the English, Chinese, and Malay versions of the 5-level EQ-5D (EQ-5D-5L) response labels in Singapore. Visitors to a primary care institution in Singapore (n = 743) were asked to complete two exercises: (1) rating the severity of the EQ-5D-5L response labels presented in English, Chinese, or Malay using a 0-100 numeric rating scale and (2) using the labels to describe various hypothetical health problems. Label ratings and choices between language versions were compared using regression analysis. Perceived severity of the English and Chinese labels was similar. Compared with their English counterparts, the Malay label "slight(ly)" was rated as more severe (adjusted mean difference: 10.5 to 14.5) and "unable"/"extreme(ly)" as less severe (adjusted mean difference: -13.3 to -11.0) (P language versions of the instrument. Future studies need to investigate ways to reduce the variations and increase the cross-cultural measurement equivalence of the instrument. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Tratamento de compactação do cólon maior em eqüídeos com fluidoterapia enteral

    OpenAIRE

    Lopes,Marco Aurélio Ferreira; Moura,Gabriela Soares de; Junqueira,Luiz Arthur Camargo; Lima,Leonardo Rodrigues de; Pinto,José de Oliveira; Dantas Filho,José; Assis,Carlos Batista de

    1998-01-01

    A eficiência da fluidoterapia por via enteral foi avaliada em 14 eqüídeos (12 eqüinos e dois muares) que apresentavam compactação do cólon maior. Os animais tinham entre um ano e meio e 20 anos de idade e todos eram alimentados com capim elefante (Pennisetum purpureum Schumach) triturado. O início dos sinais de cólica foi observado no dia do internamento em seis casos, um dia antes em cinco casos, três dias antes em um caso, quatro dias antes em um caso e seis dias antes em um caso. Um cavalo...

  18. Comprehensive analysis of proteins of pH fractionated samples using monolithic LC/MS/MS, intact MW measurement and MALDI-QIT-TOF MS

    Science.gov (United States)

    Yoo, Chul; Patwa, Tasneem H.; Kreunin, Paweena; Miller, Fred R.; Huber, Christian G.; Nesvizhskii, Alexey I.; Lubman, David M.

    2012-01-01

    A comprehensive platform that integrates information from the protein and peptide levels by combining various MS techniques has been employed for the analysis of proteins in fully malignant human breast cancer cells. The cell lysates were subjected to chromatofocusing fractionation, followed by tryptic digestion of pH fractions for on-line monolithic RP-HPLC interfaced with linear ion trap MS analysis for rapid protein identification. This unique approach of direct analysis of pH fractions resulted in the identification of large numbers of proteins from several selected pH fractions, in which approximately 1.5 μg of each of the pH fraction digests was consumed for an analysis time of ca 50 min. In order to combine valuable information retained at the protein level with the protein identifications obtained from the peptide level information, the same pH fraction was analyzed using nonporous (NPS)-RP-HPLC/ESI-TOF MS to obtain intact protein MW measurements. In order to further validate the protein identification procedures from the fraction digest analysis, NPS-RP-HPLC separation was performed for off-line protein collection to closely examine each protein using MALDI-TOF MS and MALDI-quadrupole ion trap (QIT)-TOF MS, and excellent agreement of protein identifications was consistently observed. It was also observed that the comparison to intact MW and other MS information was particularly useful for analyzing proteins whose identifications were suggested by one sequenced peptide from fraction digest analysis. PMID:17206599

  19. COMPARISON OF COMMERCIAL LC MS/MS COMPATIBLE DETERGENTS WITH SODIUM DEOXYCHOLATE FOR SHOTGUN PROTEOMICS

    Directory of Open Access Journals (Sweden)

    Caleb J. Porter

    2014-12-01

    Full Text Available In this study, we compared the performance of sodium deoxycholate (SDC with several commercially available LC MS/MS compatible detergents for digestion of complex proteomic mixtures. First, the parameters affecting in-solution digestion using SDC were investigated with a full factorial experimental design. Metrics explored were trypsin ratio, digestion time, and concentration of SDC. These parameters were not found to be statistically associated with total peptide identifications in the experimental space investigated. However, in terms of digestion efficiency, digestion time was highly significant (p = 0.0095 as determined by the percent of peptides identified with missed cleavages. The optimized protocol for peptide identification and throughput was used to compare the performance of SDC with various commercially available LC MS/MS compatible surfactants namely Invitrosol, RapiGest, and PPS Silent Surfactant. The detergents were found to be similar through comparisons of the total identified peptides and the hydrophobicity of recovered peptides. We found suitable recovery across a large range of SDC concentrations determined from a bicinchoninic acid (BCA assay. In a spike down experiment, no distinct differences in total number of peptide identifications were discovered when comparing PPS (Silent Surfactant and SDC for preparation of peptide samples derived from low protein amounts (< 20 µg. Combined, these results indicate that SDC is a cost effective alternative to other commonly used LC MS/MS compatible surfactants

  20. Emotional Intelligence and Job Satisfaction: The EQ Relationship for Deans of U.S. Business Schools

    Science.gov (United States)

    Coco, Charles M.

    2009-01-01

    The main purpose of this study was to determine if a positive relationship existed between Emotional Intelligence and Job Satisfaction for deans of business schools. A secondary purpose was to determine which Emotional Quotient (EQ) competencies were most important for satisfied deans and how these competencies assisted processes related to…

  1. Analysis of phytochemical variations in dioecious Tinospora cordifolia stems using HPLC/QTOF MS/MS and UPLC/QqQLIT -MS/MS.

    Science.gov (United States)

    Bajpai, Vikas; Singh, Awantika; Chandra, Preeti; Negi, M P S; Kumar, Nikhil; Kumar, Brijesh

    2016-01-01

    The stem of dioecious Tinospora cordifolia (Menispermaceae) is a commonly used traditional Ayurvedic medicine in India having several therapeutic properties. To develop and validate LC-MS methods for the identification and simultaneous quantitation of various secondary metabolites and to study metabolomic variations in the stem of male and female plants. Ethanolic extract of stems were analysed by HPLC/ESI-QTOF-MS/MS for rapid screening of bioactive phytochemicals. High resolution MS and MS/MS in positive ESI mode were used for structural investigation of secondary metabolites. An UPLC/ESI-QqQ(LIT) -MS/MS method in MRM mode was developed and validated for the simultaneous quantitation of five bioactive alkaloids. Identification and characterisation of 36 metabolites including alkaloids, sesquiterpenes and phytoecdysteroids were performed using LC-MS and MS/MS techniques. The bioactive alkaloids such as jatrorrhizine, magnoflorine, isocorydine, palmatine and tetrahydropalmatine were successfully quantified in male and female plants. The mean abundances of magnoflorine jatrorrhizine, and oblongine were significantly (P Phytochemicals in the stem of male and female Tinospora cordifolia showed significant qualitative and quantitative variations. LC-MS and MS/MS methods can be used to differentiate between male and female plants based on their chemical profiles and quantities of the marker bioactive alkaloids. This chemical composition difference was also evident during vegetative stage when there were no male and female flowers. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Determination of Glyphosate Levels in Breast Milk Samples from Germany by LC-MS/MS and GC-MS/MS

    NARCIS (Netherlands)

    Steinborn, Angelika; Alder, Lutz; Michalski, Britta; Zomer, Paul; Bendig, Paul; Martinez, Sandra Aleson; Mol, Hans G.J.; Class, Thomas J.; Costa Pinheiro, Nathalie

    2016-01-01

    This study describes the validation and application of two independent analytical methods for the determination of glyphosate in breast milk. They are based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS), respectively. For

  3. Influência da heparina sódica na ocorrência de laminite eqüina induzida por sobrecarga de carboidratos

    OpenAIRE

    Martins Filho,L.P.; Fagliari,J.J.; Moraes,J.R.E.; Sampaio,R.C.; Oliveira,J.A.; Lacerda Neto,J.C.

    2008-01-01

    Avaliou-se a eficiência da infusão intravenosa de heparina sódica (100UI/kg/8h, a partir de 24h após o fornecimento de carboidrato, até completar 48h) no controle da laminite eqüina experimentalmente induzida por sobrecarga de carboidrato (17,6g de amido de milho/kg de peso corpóreo). Foram utilizados 15 eqüinos adultos, distribuídos em três grupos experimentais: GI (grupo-controle); GII (grupo laminite) e GIII (grupo laminite+heparina). Posteriormente ao fornecimento de carboidrato, os anima...

  4. Cloud-based solution to identify statistically significant MS peaks differentiating sample categories.

    Science.gov (United States)

    Ji, Jun; Ling, Jeffrey; Jiang, Helen; Wen, Qiaojun; Whitin, John C; Tian, Lu; Cohen, Harvey J; Ling, Xuefeng B

    2013-03-23

    Mass spectrometry (MS) has evolved to become the primary high throughput tool for proteomics based biomarker discovery. Until now, multiple challenges in protein MS data analysis remain: large-scale and complex data set management; MS peak identification, indexing; and high dimensional peak differential analysis with the concurrent statistical tests based false discovery rate (FDR). "Turnkey" solutions are needed for biomarker investigations to rapidly process MS data sets to identify statistically significant peaks for subsequent validation. Here we present an efficient and effective solution, which provides experimental biologists easy access to "cloud" computing capabilities to analyze MS data. The web portal can be accessed at http://transmed.stanford.edu/ssa/. Presented web application supplies large scale MS data online uploading and analysis with a simple user interface. This bioinformatic tool will facilitate the discovery of the potential protein biomarkers using MS.

  5. Finding of pesticides in fashionable fruit juices by LC-MS/MS and GC-MS/MS.

    Science.gov (United States)

    Tran, Kevin; Eide, David; Nickols, Susan M; Cromer, Michele R; Sabaa-Srur, Armando; Smith, Robert E

    2012-10-15

    Products labelled as containing extracts from two mushrooms (cordyceps plus reishi) and the juices from açaí, goji, mangosteen, noni, pomegranate, and sea buckthorn have been analysed for 174 different pesticides, using the validated QuEChERS method for sample preparation and electrospray LC-MS/MS in the positive ion mode for analysis. Pesticides were found in 10 of the 21 samples analysed. Most pesticides found were below the tolerance levels (1-6 μg/g, depending on the pesticide), but some were not. This included boscalid, dimethomorph, iprovalicarb, pyridaben, pyrimethanil, and imazalil, for which there is no tolerance reported or zero tolerance in any fruit. However, genuine açaí that was harvested in the state of Pará and lyophilised in Rio de Janeiro had no detectable pesticides, when analysed by both LC-MS/MS and GC-MS/MS, which can detect 213 more pesticides and industrial chemicals. Likewise no pesticides were found in one sample each of cordyceps plus reishi, sea buckthorn and noni. Published by Elsevier Ltd.

  6. MS Based Metabonomics

    Energy Technology Data Exchange (ETDEWEB)

    Want, Elizabeth J.; Metz, Thomas O.

    2010-03-01

    1. Gas chromatography-(GC)-MS was the most commonly used MS-based method for small molecule analysis in the 1970s and 1980s. It is still used today for the detection of many metabolic disorders and plays a strong role in plant metabonomics. Liquid chromatography (LC)-MS approaches have grown in popularity for metabolite studies, due to simpler sample preparation, reduced analysis times through the introduction of ultra-high performance liquid chromatography (UPLC)-MS and the ability to observe a wider range of metabolites. This chapter will discuss the role of MS in metabonomics, the techniques involved in this exciting area, and the current and future applications of the field. The various bioinformatics tools and multivariate analysis techniques used to maximize information recovery and to aid in the interpretation of the very large data sets typically obtained in metabonomics studies will also be discussed. While there are many different MS-based approaches utilized in metabonomics studies, emphasis will be placed on more established methods.

  7. Hemogasometria de eqüinos submetidos à obstrução experimental do duodeno, íleo e cólon maior Blood gas analysis of horses submitted to experimental obstruction of duodenum, ileum and large colon

    Directory of Open Access Journals (Sweden)

    Paula Alessandra Di Filippo

    2009-02-01

    Full Text Available Visando estudar os parâmetros do equilíbrio ácido-base de eqüinos submetidos a um modelo experimental de obstrução intestinal, 24 animais foram distribuídos em quatro grupos, controle instrumentado (GI, obstrução do duodeno (GII, íleo (GIII e cólon maior (GIV. As amostras de sangue venoso foram coletadas antes das cirurgias (T0, durante as obstruções (T30ob-T180ob e após as desobstruções (T60des-T180des. Os eqüinos do GIV, no T30ob, e os eqüinos do GII, nos T60ob, T90ob e T120ob, apresentaram aumento do pH(v, da cHCO-3(vP e da cBase(v que, acrescidos do aumento da pCO2(v e da ctCO2(v, caracterizou a alcalose metabólica com compensação respiratória. Nos T90ob e T120ob, nos animais do GII, e no T180ob, nos animais do GIII, a pO2(v e a sO2(v tiveram comportamento semelhante. Os valores baixos apresentados pelos animais do GII foram associados à hipercapnia ou à hipoventilação, desencadeadas para a correção da alcalose metabólica. Entretanto, a hipoxemia apresentada pelos animais do GIII foi associada à hipovolemia presente neste período. As alterações ácido-base observadas constituem-se de alterações leves e temporárias, as quais não são capazes de predizer o diagnóstico das obstruções intestinais específicas em eqüinos com cólica. Entretanto, por relacionarem-se diretamente com a precocidade do distúrbio gastrintestinal, elas auxiliam o pesquisador no prognóstico.This study aimed to evaluate parameters of acid-base balance in horses submitted to an experimental model of intestinal obstruction. Twenty-four animals were divided in four groups: instrumented control (GI, duodenum obstruction (GII, ileum obstruction (GIII and large colon obstruction (GIV. Venous blood samples were collected before surgery (T0, during the obstruction (T30ob-T180ob and after unblocking procedures (T60des-T180des. Animals from GIV, at T30ob and animals from GII, at T60ob, T90ob and T120ob, presented higher values for pH(v, c

  8. Hydra: software for tailored processing of H/D exchange data from MS or tandem MS analyses

    Directory of Open Access Journals (Sweden)

    Bennett Melissa

    2009-05-01

    Full Text Available Abstract Background Hydrogen/deuterium exchange mass spectrometry (H/DX-MS experiments implemented to characterize protein interaction and protein folding generate large quantities of data. Organizing, processing and visualizing data requires an automated solution, particularly when accommodating new tandem mass spectrometry modes for H/DX measurement. We sought to develop software that offers flexibility in defining workflows so as to support exploratory treatments of H/DX-MS data, with a particular focus on the analysis of very large protein systems and the mining of tandem mass spectrometry data. Results We present a software package ("Hydra" that supports both traditional and exploratory treatments of H/DX-MS data. Hydra's software architecture tolerates flexible data analysis procedures by allowing the addition of new algorithms without significant change to the underlying code base. Convenient user interfaces ease the organization of raw data files and input of peptide data. After executing a user-defined workflow, extracted deuterium incorporation values can be visualized in tabular and graphical formats. Hydra also automates the extraction and visualization of deuterium distribution values. Manual validation and assessment of results is aided by an interface that aligns extracted ion chromatograms and mass spectra, while providing a means of rapidly reprocessing the data following manual adjustment. A unique feature of Hydra is the automated processing of tandem mass spectrometry data, demonstrated on a large test data set in which 40,000 deuterium incorporation values were extracted from replicate analysis of approximately 1000 fragment ions in one hour using a typical PC. Conclusion The customizable workflows and user-friendly interfaces of Hydra removes a significant bottleneck in processing and visualizing H/DX-MS data and helps the researcher spend more time executing new experiments and interpreting results. This increased

  9. Pediatric MS

    Science.gov (United States)

    ... Pediatric MS Share this page Facebook Twitter Email Pediatric MS Pediatric MS Pediatric MS Support Pediatric Providers ... system through the Pediatric MS Support Group . Treating pediatric MS In 2018 the U.S. Food and Drug ...

  10. Comparing the self-perceived quality of life of multimorbid patients and the general population using the EQ-5D-3L.

    Directory of Open Access Journals (Sweden)

    Alexandra A N'Goran

    Full Text Available To assess and compare the self-perceived Health Related Quality of Life (HRQoL of multimorbid patients and the general population using health utilities (HU and visual analogue scale (VAS methods.We analyzed data (n = 888 from a national, cross-sectional Swiss study of multimorbid patients recruited in primary care settings. Self-perceived HRQoL was assessed using the EQ-5D-3L instrument, composed of 1 a questionnaire on the five dimensions of mobility, self-care, usual activities, pain/discomfort, and anxiety/depression (EQ-5D dimensions, and 2 a 0-100 (0 = worst- and 100 = best-imaginable health status VAS. We described the EQ-5D dimensions and VAS and computed HU using a standard pan-European value set. HU and VAS are the two components of the overall HRQoL assessment. We examined the proportions of multimorbid patients reporting problems (moderate/severe in each EQ-5D dimension, corresponding proportions without problems, and mean HU and VAS values across patient characteristics. To test differences between subgroups, we used chi-square tests for dichotomous outcomes and T-tests (ANOVA if more than two groups for continuous outcomes. Finally, we compared observed and predicted HU and VAS values.All 888 participants answered every EQ-5D item. Mean (SD HU and VAS values were 0.70 (0.18 and 63.2 (19.2, respectively. HU and VAS were considerably and significantly lower in multimorbid patients than in the general population and were also lower in multimorbid patients below 60 years old and in women. Differences between observed and predicted means (SD were -0.07 (0.18 for HU and -11.8 (20.3 for VAS.Self-perceived HRQoL is considerably and significantly affected by multimorbidity. More attention should be given to developing interventions that improve the HRQoL of multimorbid patients, particularly women and those aged below 60 years old.

  11. Determination of 48 fragrance allergens in toys using GC with ion trap MS/MS.

    Science.gov (United States)

    Lv, Qing; Zhang, Qing; Li, Wentao; Li, Haiyu; Li, Pi; Ma, Qiang; Meng, Xianshuang; Qi, Meiling; Bai, Hua

    2013-11-01

    This paper presents a method for the simultaneous determination of 48 fragrance allergens in four types of toys (plastic toys, play clays, plush toys, and paper toys) based on GC with ion trap MS/MS. Compared with single-stage MS, MS/MS is superior in terms of the qualification and quantification of a large range of compounds in complicated matrices. Procedures for extraction and purification were optimized for each toy type. The method proved to be linear over a wide range of concentrations for all analytes with correlation coefficients between 0.9768 and 0.9999. Validation parameters, namely, LODs and LOQs, ranged from 0.005-5.0 and from 0.02-20 mg/kg, respectively. Average recoveries of target compounds (spiked at three concentration levels) were in the range of 79.5-109.1%. Intraday and interday repeatabilities of the proposed method varied from 0.7-10.5% and from 3.1-13.4%, respectively. The proposed method was used to monitor fragrance allergens in commercial toy products. Our findings indicate that this method is an accurate and effective technique for analyzing fragrance allergens in materials composed of complex components. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. A social preference valuations set for EQ-5D health states in Flanders, Belgium.

    Science.gov (United States)

    Cleemput, Irina

    2010-04-01

    This study aimed at deriving a preference valuation set for EQ-5D health states from the general Flemish public in Belgium. A EuroQol valuation instrument with 16 health states to be valued on a visual analogue scale was sent to a random sample of 2,754 adults. The initial response rate was 35%. Eventually, 548 (20%) respondents provided useable valuations for modeling. Valuations for 245 health states were modeled using a random effects model. The selection of the model was based on two criteria: health state valuations must be consistent, and the difference with the directly observed valuations must be small. A model including a value decrement if any health dimension of the EQ-5D is on the worst level was selected to construct the social health state valuation set. A comparison with health state valuations from other countries showed similarities, especially with those from New Zealand. The use of a single preference valuation set across different health economic evaluations within a country is highly preferable to increase their usability for policy makers. This study contributes to the standardization of outcome measurement in economic evaluations in Belgium.

  13. Comparación de las escalas EQ-5D y FACT-G en la evaluación de la calidad de vida en pacientes colombianos con cáncer

    Directory of Open Access Journals (Sweden)

    Juliet Valdelamar Jiménez

    2015-08-01

    Full Text Available Objective: To evaluate patterns of correlations between the different dimensions of a scale measuring quality of life (FACT-G and one that measures perceived health and quality of life (EQ-5D in cancer patients. Methods: A descriptive study that evaluated 114 patients with confirmed cancer of breast (40=35.09%, gastric (26=22.8%, prostate (22=19.3%, colon-rectal (17=14.91%. Diagnosis was made at the National Cancer Institute of Colombia, to whom applied the FACT-G and EQ-5D scale. Descriptive analyses were used to summarize the variables, methods of multivariate analysis, factor analysis and multidimensional scaling were used to assess patterns of correlation between the variables of each of the two scales used. Results: The dimensions that showed acceptable correlation values were physical well-being and emotional well-being of the FACT- G with anxiety and depression of the EQ- 5D scale. Factor analysis yielded two factors: (a anxiety / depression or the EQ-5D is better grouped with the components of the FACT- G, and (b physical symptoms of FACT-G with the components of the EQ-5D. Multidimensional scaling analysis suggested that each scale measured different dimensions of the construct quality of life. Conclusion: The FACT-G is oriented to emotional and social interaction, while the EQ-5D is oriented to aspects of physical and functionality.

  14. Judicialização da política pública de assistência farmacêutica e eqüidade

    OpenAIRE

    Chieffi,Ana Luiza; Barata,Rita Barradas

    2009-01-01

    O fornecimento de medicamentos por ação judicial, pela Secretaria de Estado da Saúde de São Paulo (SES-SP), tornou-se uma prática rotineira e cada vez mais freqüente. A judicialização do sistema de saúde entra em confronto com princípios básicos do SUS, como o da eqüidade. Este trabalho caracterizou as demandas judiciais para obtenção de medicamentos sob a ótica da judicialização da política pública e da quebra do princípio da eqüidade na dimensão coletiva. O estudo é um trabalho descritivo d...

  15. Freqüência de anemia infecciosa em eqüinos no Acre, 1986 a 1996

    Directory of Open Access Journals (Sweden)

    Santos R.M.L.

    2001-01-01

    Full Text Available Foram analisadas as fichas de 9.963 eqüídeos do Acre, submetidos ao teste de imunodifusão em gel de ágar (IDGA para anemia infecciosa eqüina (AIE, no período de 1986 a 1996. As regiões sócio-ecológicas da Bacia do Alto Juruá, Alto Acre e Alta Bacia do Purus apresentaram os maiores índices da doença, o que caracteriza a associação entre região e positividade. Essas áreas são fronteiriças com o Peru, Bolívia e o Estado do Amazonas, são distantes de Rio Branco, capital do Estado, onde muitas vezes é difícil o acesso pelas estradas, revelando serem áreas de risco. As regiões Oriental e Rio Branco apresentaram baixos índices de positividade. Não se observou diferença estatística entre animais positivos e negativos quanto à espécie, sexo, raça e idade.

  16. Health-related quality of life effects of enzalutamide in patients with metastatic castration-resistant prostate cancer: an in-depth post hoc analysis of EQ-5D data from the PREVAIL trial.

    Science.gov (United States)

    Devlin, Nancy; Herdman, Michael; Pavesi, Marco; Phung, De; Naidoo, Shevani; Beer, Tomasz M; Tombal, Bertrand; Loriot, Yohann; Ivanescu, Cristina; Parli, Teresa; Balk, Mark; Holmstrom, Stefan

    2017-06-23

    The effect of enzalutamide on health-related quality of life (HRQoL) in the PREVAIL trial in chemotherapy-naïve men with metastatic castration-resistant prostate cancer was analyzed using the generic EQ-5D instrument. Patients received oral enzalutamide 160 mg/day (n = 872) or placebo (n = 845). EQ-5D index and EQ-5D visual analogue scale (EQ-5D VAS) scores were evaluated at baseline, week 13, and every 12 weeks until week 61 due to sample size reduction thereafter. Changes on individual dimensions were assessed, and Paretian Classification of Health Change (PCHC) and time-to-event analyses were conducted. With enzalutamide, EQ-5D index and EQ-5D VAS scores declined more slowly versus placebo and time to diverge from full health was prolonged. Average decline in EQ-5D index (-0.042 vs. -0.070; P < .0001) and EQ-5D VAS (-1.3 vs. -4.4; P < .0001) was significantly smaller with enzalutamide. There were significant (P < .05) between-group differences favoring enzalutamide in Pain/Discomfort to week 37, Anxiety/Depression at week 13, and Usual Activities at week 25, but no significant differences for Mobility and Self-care. The PCHC analysis showed more enzalutamide patients reporting improvement than placebo patients at weeks 13, 25, and 49 (all P < .05) and week 37 (P = .0512). Enzalutamide was superior (P ≤ .0003) to placebo for time to diverge from full health and time to first deterioration on Pain/Discomfort and Anxiety/Depression dimensions. This in-depth post hoc analysis showed that enzalutamide delayed HRQoL deterioration and had beneficial effects on several HRQoL domains, including Pain/Discomfort and the proportion of patients in full health, compared with placebo, and may help to support future analyses of this type. NCT01212991.

  17. The level of physical exercise is associated with self-reported health status (EQ-5D) in adults with congenital heart disease.

    Science.gov (United States)

    Sandberg, Camilla; Engström, Karl Gunnar; Dellborg, Mikael; Thilén, Ulf; Wadell, Karin; Johansson, Bengt

    2015-02-01

    The prognosis in adults with congenital aortic valve disease is usually favourable; nevertheless, a number of medical and social factors might hamper long-term prognosis and quality of life. With a focus on physical exercise level, data from the Swedish National Registry on Congenital Heart Disease (SWEDCON) were analysed and variables associated with health-related quality of life in adults with congenital aortic valve disease were identified. In this registry study, SWEDCON was searched for adult patients with isolated congenital aortic valve disease and valid EuroQol-5Dimensions health questionnaire (EQ-5D) data. This study identified 315 patients. The majority (n = 202, 64%) reported best possible health status (EQ-5D(index) = 1) whereas 113 (35%) reported some impairment (EQ-5D(index)  3 h/week was independently associated with best possible health status (EQ-5D(index) = 1; p = 0.013). Moreover presence of cardiovascular symptoms (p 3 h/week was, as a single variable, associated with best possible health status in adults with congenital aortic valve disease. In contrast, a number of medical and social factors are associated with worse self-reported health status. Among these, symptoms, smoking, and educational level are potential targets for modification and intervention. There is a need for studies investigating the effect of increased level of physical exercise in patients with congenital aortic valve disease. © The European Society of Cardiology 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Wavelet-based peak detection and a new charge inference procedure for MS/MS implemented in ProteoWizard's msConvert.

    Science.gov (United States)

    French, William R; Zimmerman, Lisa J; Schilling, Birgit; Gibson, Bradford W; Miller, Christine A; Townsend, R Reid; Sherrod, Stacy D; Goodwin, Cody R; McLean, John A; Tabb, David L

    2015-02-06

    We report the implementation of high-quality signal processing algorithms into ProteoWizard, an efficient, open-source software package designed for analyzing proteomics tandem mass spectrometry data. Specifically, a new wavelet-based peak-picker (CantWaiT) and a precursor charge determination algorithm (Turbocharger) have been implemented. These additions into ProteoWizard provide universal tools that are independent of vendor platform for tandem mass spectrometry analyses and have particular utility for intralaboratory studies requiring the advantages of different platforms convergent on a particular workflow or for interlaboratory investigations spanning multiple platforms. We compared results from these tools to those obtained using vendor and commercial software, finding that in all cases our algorithms resulted in a comparable number of identified peptides for simple and complex samples measured on Waters, Agilent, and AB SCIEX quadrupole time-of-flight and Thermo Q-Exactive mass spectrometers. The mass accuracy of matched precursor ions also compared favorably with vendor and commercial tools. Additionally, typical analysis runtimes (∼1-100 ms per MS/MS spectrum) were short enough to enable the practical use of these high-quality signal processing tools for large clinical and research data sets.

  19. Profiling the Oxylipin and Endocannabinoid Metabolome by UPLC-ESI-MS/MS in Human Plasma to Monitor Postprandial Inflammation.

    Science.gov (United States)

    Gouveia-Figueira, Sandra; Späth, Jana; Zivkovic, Angela M; Nording, Malin L

    2015-01-01

    Bioactive lipids, including oxylipins, endocannabinoids, and related compounds may function as specific biochemical markers of certain aspects of inflammation. However, the postprandial responsiveness of these compounds is largely unknown; therefore, changes in the circulating oxylipin and endocannabinoid metabolome in response to a challenge meal were investigated at six occasions in a subject who freely modified her usual diet. The dietary change, and especially the challenge meal itself, represented a modification of precursor fatty acid status, with expectedly subtle effects on bioactive lipid levels. To detect even the slightest alteration, highly sensitive ultra-performance liquid chromatography (UPLC) coupled to electrospray ionization (ESI) tandem mass spectrometry (MS/MS) methods for bioactive lipid profiling was employed. A previously validated UPLC-ESI-MS/MS method for profiling the endocannabinoid metabolome was used, while validation of an UPLC-ESI-MS/MS method for oxylipin analysis was performed with acceptable outcomes for a majority of the parameters according to the US Food and Drug Administration guidelines for linearity (0.9938 metabolome, caused by changes in diet and ii) responsiveness to a challenge meal for a subset of the oxylipin and endocannabinoid metabolome. To summarize, we have shown proof-of-concept of our UPLC-ESI-MS/MS bioactive lipid protocols for the purpose of monitoring subtle shifts, and thereby useful to address lipid-mediated postprandial inflammation.

  20. Health-related quality of life as measured with EQ-5D among populations with and without specific chronic conditions: a population-based survey in Shaanxi Province, China.

    Science.gov (United States)

    Tan, Zhijun; Liang, Ying; Liu, Siming; Cao, Wenjun; Tu, Haibo; Guo, Lingxia; Xu, Yongyong

    2013-01-01

    The aim of this study was to examine health-related quality of life (HRQoL) as measured by EQ-5D and to investigate the influence of chronic conditions and other risk factors on HRQoL based on a distributed sample located in Shaanxi Province, China. A multi-stage stratified cluster sampling method was performed to select subjects. EQ-5D was employed to measure the HRQoL. The likelihood that individuals with selected chronic diseases would report any problem in the EQ-5D dimensions was calculated and tested relative to that of each of the two reference groups. Multivariable linear regression models were used to investigate factors associated with EQ VAS. The most frequently reported problems involved pain/discomfort (8.8%) and anxiety/depression (7.6%). Nearly half of the respondents who reported problems in any of the five dimensions were chronic patients. Higher EQ VAS scores were associated with the male gender, higher level of education, employment, younger age, an urban area of residence, access to free medical service and higher levels of physical activity. Except for anemia, all the selected chronic diseases were indicative of a negative EQ VAS score. The three leading risk factors were cerebrovascular disease, cancer and mental disease. Increases in age, number of chronic conditions and frequency of physical activity were found to have a gradient effect. The results of the present work add to the volume of knowledge regarding population health status in this area, apart from the known health status using mortality and morbidity data. Medical, policy, social and individual attention should be given to the management of chronic diseases and improvement of HRQoL. Longitudinal studies must be performed to monitor changes in HRQoL and to permit evaluation of the outcomes of chronic disease intervention programs.

  1. Estimation of minimal clinically important change of the Japanese version of EQ-5D in patients with chronic noncancer pain: a retrospective research using real-world data.

    Science.gov (United States)

    Yoshizawa, Kazutake; Kobayashi, Hisanori; Fujie, Motoko; Ogawa, Yoshimasa; Yajima, Tsutomu; Kawai, Koji

    2016-03-01

    Quality of life (QoL) is routinely assessed and evaluated in medical research. However, in Japan, there is a lack of solid cutoff criteria for evaluating QoL improvement in chronic noncancer pain management. The present study was conducted to identify the minimal clinically important change (MCIC) of the Japanese version of EuroQol-5D 3L(EQ-5D) utility score and numeric rating scale (NRS) with an emphasis on chronic noncancer pain. The data source for this post hoc research was the post-marketing surveillance (PMS) data for a tramadol/acetaminophen combination tablet, which was previously conducted in real-world settings. The parameters extracted from the PMS data were sociodemographic characteristics, NRS, EQ-5D, and dichotomous physician's global impression of treatment effectiveness (PGI). The optimal cutoff points of MCIC for EQ-5D utility and NRS scores were evaluated using receiver operating characteristics (ROC) analysis. An anchor-based approach using PGI was applied. Data of 710 patients with chronic noncancer pain were extracted from the PMS database. The NRS score decreased by 2.7 (standard deviation, 2.3) points, whereas the EQ-5D score increased by 0.16 (0.20) points at 4 weeks from baseline. The changes from baseline in NRS and EQ-5D were significantly correlated (r = 0.53, p 0.80 in both analyses. These results demonstrated novel cutoff criteria for the Japanese version of EQ-5D, focusing on patients with chronic noncancer pain. The obtained criteria were fairly consistent and can be confidently utilized as an evaluation tool in medical research on chronic noncancer pain in Japan, with additional functionality and usability for QoL assessment in pain management practice. The data source of this post hoc research was a PMS study with the identifier number UMIN000015901 at umin.ac.jp, UMIN clinical trial registry (UMIN-CTR).

  2. Health-related quality of life (EQ-5D) among homeless persons compared to a general population sample in Stockholm County, 2006.

    Science.gov (United States)

    Sun, Sun; Irestig, Robert; Burström, Bo; Beijer, Ulla; Burström, Kristina

    2012-03-01

    To describe and compare health-related quality of life (HRQoL) among homeless persons with a general population sample in Stockholm County, 2006, and to analyse the importance of certain social determinants of health among the homeless. Face-to-face interviews with 155 homeless persons and a postal survey to a general population sample, mainly based on the same questionnaire, including questions on social determinants of health and HRQoL measured with the EQ-5D. Chronic illness was three times more common among the homeless. HRQoL was worse among homeless persons than in the general population sample: the homeless reported more problems, especially more severe problems, in all the EQ-5D dimensions and had considerably lower EQ-5D(index) and EQ(VAS) score than the general population. Most problems were reported in the dimension anxiety/depression. Among the homeless, longer duration and more severe degree of homelessness lowered HRQoL, but few determinants were statistically significantly related to HRQoL. Having mental disease significantly lowered HRQoL. This study was an attempt to include hard-to-reach groups in an assessment of population health. Homeless persons had considerably worse HRQoL than the general population and reported most problems in the dimension anxiety/depression. Some diseases may contribute to causing homelessness; others may be seen as consequences. Homeless persons are a vulnerable group in society. Further interview studies are needed based on larger sample of homeless persons to explore health determinants such as sex, age, socioeconomic factors, duration and degree of homelessness, and health-related behaviours among the homeless persons.

  3. Mapping the EORTC QLQ-C30 onto the EQ-5D-3L: assessing the external validity of existing mapping algorithms.

    Science.gov (United States)

    Doble, Brett; Lorgelly, Paula

    2016-04-01

    To determine the external validity of existing mapping algorithms for predicting EQ-5D-3L utility values from EORTC QLQ-C30 responses and to establish their generalizability in different types of cancer. A main analysis (pooled) sample of 3560 observations (1727 patients) and two disease severity patient samples (496 and 93 patients) with repeated observations over time from Cancer 2015 were used to validate the existing algorithms. Errors were calculated between observed and predicted EQ-5D-3L utility values using a single pooled sample and ten pooled tumour type-specific samples. Predictive accuracy was assessed using mean absolute error (MAE) and standardized root-mean-squared error (RMSE). The association between observed and predicted EQ-5D utility values and other covariates across the distribution was tested using quantile regression. Quality-adjusted life years (QALYs) were calculated using observed and predicted values to test responsiveness. Ten 'preferred' mapping algorithms were identified. Two algorithms estimated via response mapping and ordinary least-squares regression using dummy variables performed well on number of validation criteria, including accurate prediction of the best and worst QLQ-C30 health states, predicted values within the EQ-5D tariff range, relatively small MAEs and RMSEs, and minimal differences between estimated QALYs. Comparison of predictive accuracy across ten tumour type-specific samples highlighted that algorithms are relatively insensitive to grouping by tumour type and affected more by differences in disease severity. Two of the 'preferred' mapping algorithms suggest more accurate predictions, but limitations exist. We recommend extensive scenario analyses if mapped utilities are used in cost-utility analyses.

  4. Validation and comparison of EuroQoL-5 dimension (EQ-5D) and Short Form-6 dimension (SF-6D) among stable angina patients

    OpenAIRE

    Wu, Jing; Han, Yuerong; Zhao, Fei-Li; Zhou, Jin; Chen, Zhijun; Sun, He

    2014-01-01

    Objectives Several preference-based health-related quality of life (HRQoL) instruments have been published and widely used in different populations. However no consensus has emerged regarding the most appropriate instrument in therapeutic area of stable angina. This study compared and validated the psychometric properties of two generic preference-based instruments, the EQ-5D and SF-6D, among Chinese stable angina patients. Methods Convergent validity of the EQ-5D and SF-6D was examined with ...

  5. Hemogasometria em eqüinos com compactação experimental do cólon maior tratados com sene, fluidoterapia enteral e parenteral Blood gas analysis in equine with experimental large colon impaction treated with sene, enteral and parenteral fluid therapy

    Directory of Open Access Journals (Sweden)

    José Dantas Ribeiro Filho

    2007-06-01

    Full Text Available O equilíbrio ácido-base foi estudado em eqüinos com compactação experimental do cólon maior após o uso de solução isotônica poliônica enteral, sene mais hidratação intravenosa e hidratação intravenosa. As amostras sangüíneas foram colhidas de 20 animais, quatro grupos (E8, RL, SE e C de cinco animais cada. Os animais dos grupos tratados eram portadores de compactação no cólon maior induzida experimentalmente. Eqüinos no grupo E8 receberam solução isotônica poliônica enteral (8mL kg-1 h-1 48h-1; no grupo SE, sene foram administrados na dose de 20mg kg-1, duas doses de 24/24h, mais Ringer lactato intravenoso, 10mL kg-1h(-112h-1, durante dois dias; sendo que o grupo RL recebeu Ringer lactato intravenoso (16mL kg-1h(-112h-1 durante dois dias. O grupo C, controle, não foi tratado. Entre os tratamentos testados, a fluidoterapia intravenosa com solução de Ringer lactato (RL foi o tratamento mais eficiente para a correção das variáveis hemogasométricas em eqüinos com compactação do cólon maior. A solução isotônica poliônica enteral (E8 e sene associada com fluidoterapia intravenosa (SE foram eficientes, porém em menor grau.The blood acid-base status was studied in equines when induced large colon impaction was followed by applying an isotonic polionic enteral solution, or sene associated with intravenous fluid therapy, or fluid therapy alone. The blood samples were collected in twenty animals, four groups (E8, RL, SE, and C of five animals each. Animals of the treated groups had experimentally induced colon impactions. Equines in group E8 received isotonic polionic enteral solution (8 mL kg-1 h-1 48 h-1; in group SE, sene was applied at 20mg kg-1, two doses per animal, at 24-hour intervals, along with the Ringer lactate IV, 10mL kg-1 h-1, 12 h-1, both during two days; and in the RL animals received Ringer lactate IV only (16mL kg-1 h-1 12h-1, applied during two days. Group C was the non-treated control. Among the

  6. The impact of differences between patient and general population EQ-5D-3L values on the mean tariff scores of different patient groups.

    Science.gov (United States)

    Little, Matthew H R; Reitmeir, Peter; Peters, Annette; Leidl, Reiner

    2014-06-01

    Health states can be valued by those who currently experience a health state (experienced health states [EHS]) or by the general public, who value a set of given health states (GHS) described to them. There has been debate over which method is more appropriate when making resource allocation decisions. This article informs this debate by assessing whether differences between these methods have an effect on the mean EQ-5D-3L tariff scores of different patient groups. The European tariff based on GHS valuations was compared with a German EHS tariff. Comparison was made in the context of EQ-5D-3L health states describing a number of diagnosed chronic diseases (stroke, diabetes, myocardial infarction, and cancer) taken from the Cooperative Health Research in the Augsburg Region population surveys. Comparison was made of both the difference in weighting of the dimensions of the EQ-5D-3L and differences in mean tariff scores for patient groups. Weighting of the dimensions of the EQ-5D-3L were found to be systematically different. The EHS tariff gave significantly lower mean scores for most, but not all, patient groups despite tariff scores being lower for 213 of 243 EQ-5D-3L health states using the GHS tariff. Differences were found to vary between groups, with the largest change in difference being 5.45 in the multiple stoke group. The two tariffs have systematic differences that in certain patient groups could drive the results of an economic evaluation. Therefore, the choice as to which is used may be critical when making resource allocation decisions. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  7. Dansyl-peptides matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) and tandem mass spectrometric (MS/MS) features improve the liquid chromatography/MALDI-MS/MS analysis of the proteome.

    Science.gov (United States)

    Chiappetta, Giovanni; Ndiaye, Sega; Demey, Emmanuelle; Haddad, Iman; Marino, Gennaro; Amoresano, Angela; Vinh, Joëlle

    2010-10-30

    Peptide tagging is a useful tool to improve matrix-assisted laser desorption/ionization tandem mass spectrometric (MALDI-MS/MS) analysis. We present a new application of the use of the dansyl chloride (DNS-Cl). DNS-Cl is a specific primary amine reagent widely used in protein biochemistry. It adds a fluorescent dimethylaminonaphthalene moiety to the molecule. The evaluation of MALDI-MS and MS/MS analyses of dansylated peptides shows that dansylation raises the ionization efficiency of the most hydrophilic species compared with the most hydrophobic ones. Consequently, higher Mascot scores and protein sequence coverage are obtained by combining MS and MS/MS data of native and tagged samples. The N-terminal DNS-Cl sulfonation improves the peptide fragmentation and promotes the generation of b-fragments allowing better peptide sequencing. In addition, we set up a labeling protocol based on the microwave chemistry. Peptide dansylation proved to be a rapid and cheap method to improve the performance of liquid chromatography (LC)/MALDI-MS/MS analysis at the proteomic scale in terms of peptide detection and sequence coverage. Copyright © 2010 John Wiley & Sons, Ltd.

  8. Wavelet-Based Peak Detection and a New Charge Inference Procedure for MS/MS Implemented in ProteoWizard’s msConvert

    Science.gov (United States)

    2015-01-01

    We report the implementation of high-quality signal processing algorithms into ProteoWizard, an efficient, open-source software package designed for analyzing proteomics tandem mass spectrometry data. Specifically, a new wavelet-based peak-picker (CantWaiT) and a precursor charge determination algorithm (Turbocharger) have been implemented. These additions into ProteoWizard provide universal tools that are independent of vendor platform for tandem mass spectrometry analyses and have particular utility for intralaboratory studies requiring the advantages of different platforms convergent on a particular workflow or for interlaboratory investigations spanning multiple platforms. We compared results from these tools to those obtained using vendor and commercial software, finding that in all cases our algorithms resulted in a comparable number of identified peptides for simple and complex samples measured on Waters, Agilent, and AB SCIEX quadrupole time-of-flight and Thermo Q-Exactive mass spectrometers. The mass accuracy of matched precursor ions also compared favorably with vendor and commercial tools. Additionally, typical analysis runtimes (∼1–100 ms per MS/MS spectrum) were short enough to enable the practical use of these high-quality signal processing tools for large clinical and research data sets. PMID:25411686

  9. Consequential environmental and economic life cycle assessment of green and gray stormwater infrastructures for combined sewer systems.

    Science.gov (United States)

    Wang, Ranran; Eckelman, Matthew J; Zimmerman, Julie B

    2013-10-01

    A consequential life cycle assessment (LCA) is conducted to evaluate the trade-offs between water quality improvements and the incremental climate, resource, and economic costs of implementing green (bioretention basin, green roof, and permeable pavement) versus gray (municipal separate stormwater sewer systems, MS4) alternatives of stormwater infrastructure expansions against a baseline combined sewer system with combined sewer overflows in a typical Northeast US watershed for typical, dry, and wet years. Results show that bioretention basins can achieve water quality improvement goals (e.g., mitigating freshwater eutrophication) for the least climate and economic costs of 61 kg CO2 eq. and $98 per kg P eq. reduction, respectively. MS4 demonstrates the minimum life cycle fossil energy use of 42 kg oil eq. per kg P eq. reduction. When integrated with the expansion in stormwater infrastructure, implementation of advanced wastewater treatment processes can further reduce the impact of stormwater runoff on aquatic environment at a minimal environmental cost (77 kg CO2 eq. per kg P eq. reduction), which provides support and valuable insights for the further development of integrated management of stormwater and wastewater. The consideration of critical model parameters (i.e., precipitation intensity, land imperviousness, and infrastructure life expectancy) highlighted the importance and implications of varying local conditions and infrastructure characteristics on the costs and benefits of stormwater management. Of particular note is that the impact of MS4 on the local aquatic environment is highly dependent on local runoff quality indicating that a combined system of green infrastructure prior to MS4 potentially provides a more cost-effective improvement to local water quality.

  10. Non-enzymolytic adenosine barcode-mediated dual signal amplification strategy for ultrasensitive protein detection using LC-MS/MS.

    Science.gov (United States)

    Yang, Wen; Li, Tengfei; Shu, Chang; Ji, Shunli; Wang, Lei; Wang, Yan; Li, Duo; Mtalimanja, Michael; Sun, Luning; Ding, Li

    2018-05-10

    A method is described for the determination of proteins with LC-MS/MS enabled by a small molecule (adenosine) barcode and based on a double-recognition sandwich structure. The coagulation protein thrombin was chosen as the model analyte. Magnetic nanoparticles were functionalized with aptamer29 (MNP/apt29) and used to capture thrombin from the samples. MNP/apt29 forms a sandwich with functionalized gold nanoparticles modified with (a) aptamer15 acting as thrombin-recognizing element and (b) a large number of adenosine as mass barcodes. The sandwich formed (MNP/apt29-thrombin-apt15/AuNP/adenosine) can ben magnetically separated from the sample. Mass barcodes are subsequently released from the sandwiched structure for further analysis by adding 11-mercaptoundecanoic acid. Adenosine is then detected by LC-MS/MS as it reflects the level of thrombin with impressively amplified signal. Numerous adenosines introduced into the sandwich proportional to the target concentration further amplify the signal. Under optimized conditions, the response is linearly proportional to the thrombin concentration in the range of 0.02 nM to 10 nM, with a detection limit of 9 fM. The application of this method to the determination of thrombin in spiked plasma samples gave recoveries that ranged from 92.3% to 104.7%. Graphical abstract Schematic representation of a method for the determination of thrombin with LC-MS/MS. The method is based on a double-recognition sandwiched structure. With LC-MS/MS, mass barcodes (adenosine) are detected to quantify thrombin, which amplifies the detection signal impressively.

  11. Gaining knowledge from previously unexplained spectra-application of the PTM-Explorer software to detect PTM in HUPO BPP MS/MS data.

    Science.gov (United States)

    Chamrad, Daniel C; Körting, Gerhard; Schäfer, Heike; Stephan, Christian; Thiele, Herbert; Apweiler, Rolf; Meyer, Helmut E; Marcus, Katrin; Blüggel, Martin

    2006-09-01

    A novel software tool named PTM-Explorer has been applied to LC-MS/MS datasets acquired within the Human Proteome Organisation (HUPO) Brain Proteome Project (BPP). PTM-Explorer enables automatic identification of peptide MS/MS spectra that were not explained in typical sequence database searches. The main focus was detection of PTMs, but PTM-Explorer detects also unspecific peptide cleavage, mass measurement errors, experimental modifications, amino acid substitutions, transpeptidation products and unknown mass shifts. To avoid a combinatorial problem the search is restricted to a set of selected protein sequences, which stem from previous protein identifications using a common sequence database search. Prior to application to the HUPO BPP data, PTM-Explorer was evaluated on excellently manually characterized and evaluated LC-MS/MS data sets from Alpha-A-Crystallin gel spots obtained from mouse eye lens. Besides various PTMs including phosphorylation, a wealth of experimental modifications and unspecific cleavage products were successfully detected, completing the primary structure information of the measured proteins. Our results indicate that a large amount of MS/MS spectra that currently remain unidentified in standard database searches contain valuable information that can only be elucidated using suitable software tools.

  12. Digestão dos carboidratos de alimentos volumosos em eqüinos Digestion of carbohydrates of forages in horses

    Directory of Open Access Journals (Sweden)

    Eliane da Silva Morgado

    2009-01-01

    Full Text Available Neste estudo, foram realizados dois ensaios com os objetivos de avaliar o fracionamento dos carboidratos de alimentos volumosos e estimar a digestibilidade desses nutrientes em dois ensaios de digestão com eqüinos. No ensaio 1, foram utilizados cinco eqüinos em delineamento de blocos casualizados, com sete tratamentos - fenos de alfafa (Medicago sativa; amendoim forrageiro (Arachis pintoi; desmódio (Desmodium ovalifolium; guandu (Cajanus cajan; macrotiloma (Macrotyloma axillare; estilosantes (Stylosanthes guianensis; ou coastcross (Cynodon dactylon - avaliados pela técnica de sacos de náilon móveis. No ensaio 2, foram utilizados quatro eqüinos em delineamento quadrado latino 4 × 4, alimentados com feno de coastcross em quatro tipos de moagem com o objetivo de avaliar se a redução do tamanho de partícula interfere na digestibilidade dos carboidratos. Os resultados comprovaram que os eqüinos possuem alta eficiência na digestão dos carboidratos não-fibrosos e de suas frações hidrolisáveis e rapidamente fermentáveis. Os fenos de amendoim forrageiro, estilosantess e macrotiloma apresentaram elevada digestibilidade dos carboidratos fibrosos e não-fibrosos, enquanto a digestibilidade de todos os nutrientes do amendoim forrageiro foi superior a 70%, o que indica potencial para uso desta leguminosa em dietas para eqüinos. O processamento do feno de coastcross não influenciou a digestibilidade das frações dos carboidratos fibrosos e não-fibrosos. A análise dos carboidratos fibrosos e não-fibrosos é um bom indicativo do valor nutricional dos alimentos e pode ser incluída na avaliação da qualidade de alimentos para eqüinos.This work was carried out to evaluate the fractions of carbohydrates and estimate the apparent digestibility of these nutrients in two digestion assays with horses. In assay 1, five horses were allotted to a complete randomized blocks design and treatments were seven forages hays, alfalfa (Medicago sativa

  13. UFLC-ESI-MS/MS analysis of multiple mycotoxins in medicinal and edible Areca catechu.

    Science.gov (United States)

    Liu, Hongmei; Luo, Jiaoyang; Kong, Weijun; Liu, Qiutao; Hu, Yichen; Yang, Meihua

    2016-05-01

    A robust, sensitive and reliable ultra fast liquid chromatography combined with electrospray ionization tandem mass spectrometry (UFLC-ESI-MS/MS) was optimized and validated for simultaneous identification and quantification of eleven mycotoxins in medicinal and edible Areca catechu, based on one-step extraction without any further clean-up. Separation and quantification were performed in both positive and negative modes under multiple reaction monitoring (MRM) in a single run with zearalanone (ZAN) as internal standard. The chromatographic conditions and MS/MS parameters were carefully optimized. Matrix-matched calibration was recommended to reduce matrix effects and improve accuracy, showing good linearity within wide concentration ranges. Limits of quantification (LOQ) were lower than 50 μg kg(-1), while limits of detection (LOD) were in the range of 0.1-20 μg kg(-1). The accuracy of the developed method was validated for recoveries, ranging from 85% to 115% with relative standard deviation (RSD) ≤14.87% at low level, from 75% to 119% with RSD ≤ 14.43% at medium level and from 61% to 120% with RSD ≤ 13.18% at high level, respectively. Finally, the developed multi-mycotoxin method was applied for screening of these mycotoxins in 24 commercial samples. Only aflatoxin B2 and zearalenone were found in 2 samples. This is the first report on the application of UFLC-ESI(+/-)-MS/MS for multi-class mycotoxins in A. catechu. The developed method with many advantages of simple pretreatment, rapid determination and high sensitivity is a proposed candidate for large-scale detection and quantification of multiple mycotoxins in other complex matrixes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. MALDI-TOF MS/MS measurements of PMMA

    NARCIS (Netherlands)

    Becer, C.R.; Baumgaertel, A.; Gottschaldt, M.; Schubert, U.S.

    2008-01-01

    The polymer poly(Me methacrylate) (PMMA) was analyzed using the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) technique. The MALDI-TOF MS app. was coupled with a collision-induced dissocn. (CID) unit. The performance of the MALDI-TOF/TOF MS method in

  15. Evaluation of Normalization Methods to Pave the Way Towards Large-Scale LC-MS-Based Metabolomics Profiling Experiments

    Science.gov (United States)

    Valkenborg, Dirk; Baggerman, Geert; Vanaerschot, Manu; Witters, Erwin; Dujardin, Jean-Claude; Burzykowski, Tomasz; Berg, Maya

    2013-01-01

    Abstract Combining liquid chromatography-mass spectrometry (LC-MS)-based metabolomics experiments that were collected over a long period of time remains problematic due to systematic variability between LC-MS measurements. Until now, most normalization methods for LC-MS data are model-driven, based on internal standards or intermediate quality control runs, where an external model is extrapolated to the dataset of interest. In the first part of this article, we evaluate several existing data-driven normalization approaches on LC-MS metabolomics experiments, which do not require the use of internal standards. According to variability measures, each normalization method performs relatively well, showing that the use of any normalization method will greatly improve data-analysis originating from multiple experimental runs. In the second part, we apply cyclic-Loess normalization to a Leishmania sample. This normalization method allows the removal of systematic variability between two measurement blocks over time and maintains the differential metabolites. In conclusion, normalization allows for pooling datasets from different measurement blocks over time and increases the statistical power of the analysis, hence paving the way to increase the scale of LC-MS metabolomics experiments. From our investigation, we recommend data-driven normalization methods over model-driven normalization methods, if only a few internal standards were used. Moreover, data-driven normalization methods are the best option to normalize datasets from untargeted LC-MS experiments. PMID:23808607

  16. Report on the survey of geothermal development at Okushiri Island, Hokkaido. Geochemical survey (GC/MS and MS method); Hokkaido Okushiritou chinetsu kaihatsu chosa chikagaku chosa (GC/MS and MS ho) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-09-01

    To elucidate chemical components of soil gas in the Okushiri Island area, soil gas was collected by the method using charcoal adsorbent, and analysis was made by the GC/MS method. Out of the 19 measuring points, 17 points were set up near the measuring points in the FY 1998 survey by the finger print method. At the same measuring points, analytical survey by the MS method was also conducted to sort the type of soil gas. As a result of the GC/MS analysis, xylene or ethyl benzene was detected at 12 measuring points of all 19 measuring points, and from the distribution, it was predicted that there were anomaly zones in the district along the road of the Okushiri Island line and the district southward from the 5.8K Pass. These results were in harmony with the results of the survey by the finger print method. As to the sorting of soil gas based on the results of the MS analysis, the results were different at 8 measuring points from those of the survey by the finger print method in FY 1998. It was considered that the cause was the accidental vaporization of a large quantity of acetaldehyde, and acetaldehyde was regarded as a noise gas component that does not reflect the geothermal structure. (NEDO)

  17. Design Considerations for Large Computer Communication Networks,

    Science.gov (United States)

    1976-04-01

    Differentiating Eq. (4.49a) with respect the PB’ we find BA 157 bV .- • PBH’ I P - 1+11 [1 PB] dPB NA 2 From the definition of H(z), Eq. (A.25) H’(z) = 2 kzk -lP...25), we arrive at p-i Nk k H(z) k N - k k=l z(.0 and from Eq. (A.27), H(Z) = N " Y kzk + p (p k)zk k=l k=(p+l)/2 To evaluate the above summations we

  18. LC-MS based Metabolomics

    DEFF Research Database (Denmark)

    Magdenoska, Olivera

    . The analytical tools applied for analysis of intracellular metabolites should be capable to cope with the large number of metabolites to be analyzed and the complex matrix in the samples. Therefore the combination of separation and detection techniques is commonly applied for analysis of intracellular........ In the studies conducted during this Ph.D. the developed method was used to understand how the genetic manipulations in various organisms, influence the levels of their intracellular metabolites. The method development was divided into three steps: i) optimization of the MS detection, ii) establishment...... of the MS detection aimed to determine multiple reaction monitoring (MRM) transitions of the analytes and to increase the sensitivity by testing different ion-source parameters and collision energies. This resulted in optimized detection of more than 50 intracellular metabolites. During the optimization...

  19. Targeted LC-MS/MS method for quantification of Plant Lignans and Enterolignans in Biofluids from Humans and Pigs

    DEFF Research Database (Denmark)

    Nørskov, Natalja; Olsen, Anja; Tjønneland, Anne

    2015-01-01

    Lignans have gained nutritional interest due to their promising role in the prevention of lifestyle diseases. However, epidemiological studies are in need of more evidence to link the intake of lignans to this promising role. In this context, it is necessary to study large population groups...... to obtain sufficient statistical power. Therefore, there is a demand for fast, sensitive, and accurate methods for quantitation with high throughput of samples. This paper presents a validated LC-MS/MS method for the quantitation of eight plant lignans (matairesinol, hydroxymatairesinol...

  20. Associations between community-based physiotherapy for musculoskeletal injury and health related quality of life (EQ-5D): a multi-centre retrospective analysis.

    Science.gov (United States)

    Caplan, Nick; Robson, H; Robson, A; Barry, G; Wilkes, G

    2017-10-25

    Community-based musculoskeletal physiotherapy is used to improve function and health related quality of life (HRQoL). The purpose of this retrospective, multi-centre observational study was to determine the association between community-based physiotherapy management for musculoskeletal disorders and changes in HRQoL. Four thousand one hundred twelve patients' data were included in the study. Patients were included if they received a single period of treatment for a musculoskeletal injury or disorder. Patients were only included if they were being treated for a single morbidity. Patients received standard physiotherapy appropriate to their specific disorder, which could include health education/advice, exercise therapy, manual therapy, taping, soft tissue techniques, electrotherapy and/or acupuncture. Health related quality of life was assessed using the EQ-5D index. EQ-5D improved by 0.203 across all patients (d = 1.10). When grouped by anatomical site of symptom, the largest increases in EQ-5D was in foot pain (0.233; d = 1.29) and lumbar pain (0.231; d = 1.13). Improvements in EQ-5D greater than the minimum clinically important difference (MCID) were seen in 68.4% of all patients. The highest proportion of patients with positive responses to treatment were in ankle pain (74.2%) and thoracic pain (73.4%). The hand (40.5%), elbow (34.7%), and hip (33.9%) showed the greatest proportion of patients that did not respond to treatment. Community-based musculoskeletal physiotherapy is associated with improved health related quality of life. A randomised controlled trial is needed to determine any causal relationship between community-based physiotherapy and health related quality of life improvements.

  1. Wide-scope screening of pesticides in fruits and vegetables using information-dependent acquisition employing UHPLC-QTOF-MS and automated MS/MS library searching.

    Science.gov (United States)

    Wang, Zhibin; Cao, Yanzhong; Ge, Na; Liu, Xiaomao; Chang, Qiaoying; Fan, Chunlin; Pang, Guo-Fang

    2016-11-01

    This paper presents an application of ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) for simultaneous screening and identification of 427 pesticides in fresh fruit and vegetable samples. Both full MS scan mode for quantification, and an artificial-intelligence-based product ion scan mode information-dependent acquisition (IDA) providing automatic MS to MS/MS switching of product ion spectra for identification, were conducted by one injection. A home-in collision-induced-dissociation all product ions accurate mass spectra library containing more than 1700 spectra was developed prior to actual application. Both qualitative and quantitative validations of the method were carried out. The result showed that 97.4 % of the pesticides had the screening detection limit (SDL) less than 50 μg kg -1 and more than 86.7 % could be confirmed by accurate MS/MS spectra embodied in the home-made library. Meanwhile, calibration curves covering two orders of magnitude were performed, and they were linear over the concentration range studied for the selected matrices (from 5 to 500 μg kg -1 for most of the pesticides). Recoveries between 80 and 110 % in four matrices (apple, orange, tomato, and spinach) at two spiked levels, 10 and 100 μg kg -1 , was 88.7 or 86.8 %. Furthermore, the overall relative standard deviation (RSD, n = 12) for 94.3 % of the pesticides in 10 μg kg -1 and 98.1 % of the pesticides in 100 μg kg -1 spiked levels was less than 20 %. In order to validate the suitability for routine analysis, the method was applied to 448 fruit and vegetable samples purchased in different local markets. The results show 83.3 % of the analyzed samples have positive findings (higher than the limits of identification and quantification), and 412 commodity-pesticide combinations are identified in our scope. The approach proved to be a cost-effective, time-saving and powerful strategy for routine large

  2. Equilíbrio ácido-base e hidroeletrolítico em eqüinos com cólica Acid-base and hidroelectrolytic balance in colic horses

    Directory of Open Access Journals (Sweden)

    Paula Alessandra Di Filippo

    2008-08-01

    Full Text Available Foram utilizados setenta eqüinos distribuídos em três grupos experimentais, G1 (vinte eqüinos hígidos, G2 (vinte e cinco eqüinos com cólica, os quais passaram por tratamento clínico ou cirúrgico e sobreviveram e G3 (vinte e cinco eqüinos com cólica, os quais passaram por tratamento clínico ou cirúrgico e foram a óbito ou foram sacrificados. Amostras de sangue foram obtidas em dez diferentes momentos, mediante punção da jugular, para estudo do equilíbrio ácido-base e hidroeletrolítico. Os eqüinos com cólica apresentaram diminuição (PSeventy horses were distributed into three experimental groups ad follows: G1, twenty healthy animals; G2, twenty-five colic horses that survived after clinical or surgical treatment; and G3, twenty-five colic horses that were sacrificed or died after clinical or surgical treatment. Blood samples were taken from the jugular vein to assess acid-base balance and water-electrolyte balance. Colic horses had lower pH(v (P<0.05, mainly G3 animals. Acidosis was confirmed by the lower pH(v associated with decreased pCO2(v, cBase(v and cHCO-3(vP, which was probably due to an increased production of lactate during anaerobic glycolysis as a result from hypovolemia. Furthermore, hyponatremia, hypokalemia and hyperchloremia were detected. The presence and the extent of the imbalances contributed substantially to the prognosis of colic horses.

  3. Investigating Differences in Health-Related Quality of Life of Greeks and Albanian Immigrants with the Generic EQ-5D Questionnaire

    Directory of Open Access Journals (Sweden)

    Eleni Lahana

    2013-01-01

    Full Text Available Background. Low socioeconomic status (SES has been related by previous studies to low self-perceived HRQoL. Health is a major determinant of the society’s welfare, and few studies have determined the relevant elements that contribute to health and quality of life in Greece. Aim. The aim of the study was to evaluate and test for differences in HRQoL of Greek and Albanian immigrant population according to ethnicity and their demographic and SES characteristics. Methods. The study was conducted in a sample of 660 age-matched and gender-matched Greeks and Albanian immigrants. Moderate or severe decrease in HRQoL was assessed with the generic tool EQ-5D. Differences were statistically analyzed by t-test and ANOVA. Also, logistic and linear regression analyses were conducted for the dependent variables of the EQ-5D dimensions and VAS scores, respectively. Results. The Albanian immigrants reported better self-perceived health than their Greek counterparts. Health problems increase moderately with age and lower SES and are slightly higher for women than for men. Urbanity and superior education in both Greeks and Albaniansareassociated with worse HRQoL. Conclusion. There are some structural and compositional differences in the self-perceived quality of life between the two ethnicities, as estimated by EQ-5D. The combined information presentstopublic health providers the relevant data to assess health policies according to health needs.

  4. Computer-aided method for identification of major flavone/flavonol glycosides by high-performance liquid chromatography-diode array detection-tandem mass spectrometry (HPLC-DAD-MS/MS).

    Science.gov (United States)

    Wang, Zhengfang; Lin, Longze; Harnly, James M; Harrington, Peter de B; Chen, Pei

    2014-11-01

    A new computational tool is proposed here for tentatively identifying major (UV quantifiable) flavone/flavonol glycoside peaks of high performance liquid chromatogram (HPLC)-diode array detection (DAD)-tandem mass spectrometry (MS/MS) profiles based on a MATLAB-based script implementing an in-house algorithm. The HPLC-DAD-MS/MS profiles of red onion, Chinese lettuce, carrot leaf, and celery seed extracts were analyzed by the proposed computer-aided screening method for identifying possible flavone/flavonol glycoside peaks from the HPLC-UV and MS total ion current (TIC) chromatograms. The number of identified flavone/flavonol glycoside peaks of the HPLC-UV chromatograms is four, four, six, and nine for red onion, Chinese lettuce, carrot leaf, and celery seed, respectively. These results have been validated by human(s) experts. For the batch processing of nine HPLC-DAD-MS/MS profiles of celery seed extract, the entire script execution time was within 15 s while manual calculation of only one HPLC-DAD-MS/MS profile by a flavonoid expert could take hours. Therefore, this MATLAB-based screening method is able to facilitate the HPLC-DAD-MS/MS analysis of flavone/flavonol glycosides in plants to a large extent.

  5. Development of the web-based Spanish and Catalan versions of the Euroqol 5D-Y (EQ-5D-Y) and comparison of results with the paper version.

    Science.gov (United States)

    Robles, Noemí; Rajmil, Luis; Rodriguez-Arjona, Dolors; Azuara, Marta; Codina, Francisco; Raat, Hein; Ravens-Sieberer, Ulrike; Herdman, Michael

    2015-06-03

    The objectives of the study were to develop web-based Spanish and Catalan versions of the EQ-5D-Y, and to compare scores and psychometric properties with the paper version. Web-based and paper versions of EQ-5D-Y were included in a cross-sectional study in Palafolls (Barcelona), Spain and administered to students (n = 923) aged 8 to 18 years from 2 primary and 1 secondary school and their parents. All students completed both the web-based and paper versions during school time with an interval of at least 2 h between administrations. The order of administration was randomized. Participants completed EQ-5D-Y, a measure of mental health status (the Strengths and Difficulties Questionnaire), and sociodemographic variables using a self-administered questionnaire. Parents questionnaire included parental level of education and presence of chronic conditions in children. Missing values, and floor and ceiling effects were compared between versions. Mean score differences were computed for the visual analogue scale (VAS). Percentage of agreement, kappa index (k) and intraclass correlation coefficient (ICC) were computed to analyze the level of agreement between web-based and paper versions on EQ-5D-Y dimensions and VAS. Known groups validity was analyzed and compared between the two formats. Participation rate was 77 % (n = 715). Both formats of EQ-5D-Y showed low percentages of missing values (n = 2, and 4 to 9 for web and paper versions respectively), and a high ceiling effect by dimension (range from 79 % to 96 %). Percent agreement for EQ-5D-Y dimensions on the web and paper versions was acceptable (range 89 % to 97 %), and k ranged from 0.55 (0.48-0.61, usual activities dimension) to 0.75 (0.68-0.82, mobility dimension). Mean score difference on the VAS was 0.07, and the ICC for VAS scores on the two formats was 0.84 (0.82-0.86). Both formats showed acceptable ability to discriminate according to self-perceived health, reporting chronic conditions, and

  6. EQ-5D™-derived utility values for different levels of migraine severity from a UK sample of migraineurs

    Directory of Open Access Journals (Sweden)

    Stafford Megan R

    2012-06-01

    Full Text Available Abstract Background To estimate utility values for different levels of migraine pain severity from a United Kingdom (UK sample of migraineurs. Methods One hundred and six migraineurs completed the EQ-5D to evaluate their health status for mild, moderate and severe levels of migraine pain severity for a recent migraine attack, and for current health defined as health status within seven days post-migraine attack. Statistical tests were used to evaluate differences in mean utility scores by migraine severity. Results Utility scores for each health state were significantly different from 1.0 (no problems on any EQ-5D dimension (p  Conclusions Results indicate that all levels of migraine pain are associated with significantly reduced utility values. As severity worsened, utility decreased and severe migraine pain was considered a health state worse than death. Results can be used in cost-utility models examining the relative economic value of therapeutic strategies for migraine in the UK.

  7. LC-MS (/MS) in clinical toxicology screening methods.

    Science.gov (United States)

    Viette, Véronique; Hochstrasser, Denis; Fathi, Marc

    2012-01-01

    Toxicological screening is the analysis of biological samples to detect and identify unknown compounds. The high selectivity and sensitivity of liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) technology provide an attractive alternative to the current methods (LC-UV, GC/MS, etc.). For these reasons, an increasing number of applications are being published. This paper is a brief overview of LC-MS(/MS) screening methods developed for clinical toxicology in recent years. Various sample treatments, chromatographic separations and detection by mass spectrometry can be combined to obtain screening methods adapted to the constraints and needs of clinical toxicology laboratories. Currently the techniques are in the hands of specialists, mainly in academic institutions. However, the evolution in technology should allow application of these techniques as a tool in toxicology laboratories, thus allowing a more widespread exploitation of their potential.

  8. Contribution to the risk characterization of ciguatoxins: LOAEL estimated from eight ciguatera fish poisoning events in Guadeloupe (French West Indies)

    International Nuclear Information System (INIS)

    Hossen, Virginie; Soliño, Lucia; Leroy, Patricia; David, Eric; Velge, Pierre; Dragacci, Sylviane; Krys, Sophie; Flores Quintana, Harold; Diogène, Jorge

    2015-01-01

    From 2010 to 2012, 35 ciguatera fish poisoning (CFP) events involving 87 individuals who consumed locally-caught fish were reported in Guadeloupe (French West Indies). For 12 of these events, the presence of ciguatoxins (CTXs) was indicated in meal remnants and in uncooked fish by the mouse bioassay (MBA). Caribbean ciguatoxins (C-CTXs) were confirmed by liquid chromatography–tandem mass spectrometry (LC–MS/MS) analysis. Using a cell-based assay (CBA), and the only available standard Pacific ciguatoxin-1 (P-CTX-1), the lowest toxins level detected in fish samples causing CFP was 0.022 µg P-CTX-1 equivalent (eq.)·kg −1 fish. Epidemiological and consumption data were compiled for most of the individuals afflicted, and complete data for establishing the lowest observable adverse effects level (LOAEL) were obtained from 8 CFP events involving 21 individuals. Based on toxin intakes, the LOAEL was estimated at 4.2 ng P-CTX-1 eq./individual corresponding to 48.4 pg P-CTX-1 eq. kg −1 body weight (bw). Although based on limited data, these results are consistent with the conclusions of the European Food Safety Authority (EFSA) opinion which indicates that a level of 0.01 µg P-CTX-1 eq. kg −1 fish, regardless of source, should not exert effects in sensitive individuals when consuming a single meal. The calculated LOAEL is also consistent with the U.S. Food and Drug Administration guidance levels for CTXs (0.1 µg C-CTX-1 eq. kg −1 and 0.01 µg P-CTX-1 eq. kg −1 fish). - Highlights: • We report on an epidemiological study on Ciguatera events in the French West Indies. • The collection of consumption data allows for the first time the LOAEL determination. • The LOAEL for ciguatoxins was established at 48.4 pg P-CTX-1 eq. kg −1 bw. • LC–MS/MS provided structural confirmation of C-CTX1 in two suspected samples • Neuro-2A CBA is suitable for assessing composite toxicity levels in fish samples.

  9. INFLUENCIA DE LOS PROBLEMAS CRÓNICOS DE SALUD EN LAS DIMENSIONES DEL CUESTIONARIO EQ-5D: ESTUDIO EN PERSONAS MAYORES INSTITUCIONALIZADAS Y NO INSTITUCIONALIZADAS

    Directory of Open Access Journals (Sweden)

    María Concepción Delgado-Sanz

    2011-01-01

    Full Text Available Fundamento: Las enfermedades crónicas representan factores de riesgo para la calidad de vida relacionada con la salud (CVRS. El objetivo de estudio es analizar la influencia de problemas crónicos de salud autodeclarados en la CVRS, medida a través de las dimensiones del EQ-5D, en personas mayores institucionalizada y no institucionalizada. Métodos: Los datos proceden de dos estudios sobre calidad de vida en personas con 60 o más años de edad, en España, con una muestra de 1.106 personas mayores viviendo en la comunidad, y 234 en centros residenciales. Para analizar la influencia de los problemas crónicos más prevalentes en la CVRS se ajustaron modelos de regresión logística tomando como variable dependiente cada dimensión del EQ-5D y controlando por variables sociodemográficas. Resultados: Los problemas crónicos de salud que influyeron negativamente en la CVRS de los dos grupos de población estudiados, fueron la depresión (rango de OR en las distintas dimensiones del EQ-5D:1,97-6,48, seguida de artrosis/artritis (OR:2,81-6,00, insomnio (OR:2,81-4,61, diabetes (OR:1,68-3,44 e hipertensión arterial (OR:1,42-2,45. Estos problemas afectaron de forma distinta a las dimensiones del EQ-5D y a los dos grupos considerados. Las dimensiones del EQ-5D en las que se observaron más dificultades fueron dolor/malestar y movilidad. Conclusiones: Los resultados de este trabajo indican que el carácter debilitante de las enfermedades crónicas sobre la CVRS es distinto en personas mayores institucionalizadas y no institucionalizadas. Además, destacan la importancia de la promoción de un envejecimiento saludable para atenuar el impacto negativo de los problemas crónicos de la salud sobre la población mayor.

  10. JS-MS: a cross-platform, modular javascript viewer for mass spectrometry signals.

    Science.gov (United States)

    Rosen, Jebediah; Handy, Kyle; Gillan, André; Smith, Rob

    2017-11-06

    Despite the ubiquity of mass spectrometry (MS), data processing tools can be surprisingly limited. To date, there is no stand-alone, cross-platform 3-D visualizer for MS data. Available visualization toolkits require large libraries with multiple dependencies and are not well suited for custom MS data processing modules, such as MS storage systems or data processing algorithms. We present JS-MS, a 3-D, modular JavaScript client application for viewing MS data. JS-MS provides several advantages over existing MS viewers, such as a dependency-free, browser-based, one click, cross-platform install and better navigation interfaces. The client includes a modular Java backend with a novel streaming.mzML parser to demonstrate the API-based serving of MS data to the viewer. JS-MS enables custom MS data processing and evaluation by providing fast, 3-D visualization using improved navigation without dependencies. JS-MS is publicly available with a GPLv2 license at github.com/optimusmoose/jsms.

  11. Analysis of acrylamide by LC-MS/MS and GC-MS in processed Japanese foods.

    Science.gov (United States)

    Ono, H; Chuda, Y; Ohnishi-Kameyama, M; Yada, H; Ishizaka, M; Kobayashi, H; Yoshida, M

    2003-03-01

    Acrylamide concentrations in processed foods (63 samples covering 31 product types) from Japan were analysed by LC-MS/MS and GC-MS methods. The limit of detection and limit of quantification of acrylamide were 0.2 ng x ml(-1) (6 fmol) and 0.8 ng x ml(-1) (22 fmol), respectively, by LC-MS/MS, and those of 2,3-dibromopropionamide derived from acrylamide were 12 ng x ml(-1) (52 fmol) and 40 ng x ml(-1) (170 fmol), respectively, by GC-MS. Repeatability given as RSD was 1000 microg x kg(-1). The concentrations in non-whole potato-based snacks, rice crackers processed by grilling or frying, and candied sweet potatoes were lower compared with those in the potato crisps and the whole potato-based fried snacks. One of the whole potato-based fried snacks, however, showed low acrylamide concentration (instant precooked noodles and won-tons were <100 microg x kg(-1) with only one exception. Roasted barley grains for 'Mugi-cha' tea contained 200-600 microg x kg(-1) acrylamide.

  12. Methods in endogenous steroid profiling - A comparison of gas chromatography mass spectrometry (GC-MS) with supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS).

    Science.gov (United States)

    Teubel, Juliane; Wüst, Bernhard; Schipke, Carola G; Peters, Oliver; Parr, Maria Kristina

    2018-06-15

    In various fields of endocrinology, the determination of steroid hormones synthesised by the human body plays an important role. Research on central neurosteroids has been intensified within the last years, as they are discussed as biomarkers for various cognitive disorders. Their concentrations in cerebrospinal fluid (CSF) are considered to be regulated independently from peripheral fluids. For that reason, the challenging matrix CSF becomes a very interesting specimen for analysis. Concentrations are expected to be very low and available amount of CSF is limited. Thus, a comprehensive method for very sensitive quantification of a set of analytes as large as possible in one analytical aliquot is desired. However, high structural similarities of the selected panel of 51 steroids and steroid sulfates, including numerous isomers, challenges achievement of chromatographic selectivity. Since decades the analysis of endogenous steroids in various body fluids is mainly performed by gas chromatography (GC) coupled to (tandem) mass spectrometry (MS(/MS)). Due to the structure of the steroids of interest, derivatisation is performed to meet the analytical requirements for GC-MS(/MS). Most of the laboratories use a two-step derivatisation in multi-analyte assays that was already published in the 1980s. However, for some steroids this elaborate procedure yields multiple isomeric derivatives. Thus, some laboratories utilize (ultra) high performance liquid chromatography ((U)HPLC)-MS/MS as alternative but, even UHPLC is not able to separate some of the isomeric pairs. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to GC and (U)HPLC may help to overcome these issues. Within this project the two most promising methods for endogenous steroid profiling were investigated and compared: the "gold standard" GC-MS and the orthogonal separation technique SFC-MS/MS. Different derivatisation procedures for gas chromatographic detection were explored and the

  13. Household income, income inequality, and health-related quality of life measured by the EQ-5D in Shaanxi, China: a cross-sectional study.

    Science.gov (United States)

    Tan, Zhijun; Shi, Fuyan; Zhang, Haiyue; Li, Ning; Xu, Yongyong; Liang, Ying

    2018-03-14

    In advanced economies, economic factors have been found to be associated with many health outcomes, including health-related quality of life (HRQL), and people's health is affected more by income inequality than by absolute income. However, few studies have examined the association of income inequality and absolute income with HRQL in transitional economies using individual data. This paper focuses on the effects of county or district income inequality and absolute income on the HRQL measured by EQ-5D and the differences between rural and urban regions in Shaanxi province, China. Data were collected from the 2008 National Health Service Survey conducted in Shaanxi, China. The EQ-5D index based on Japanese weights was employed as a health indicator. The income inequality was calculated on the basis of self-reported income. The special requirements for complex survey data analysis were considered in the bivariate analysis and linear regression models. The mean of the EQ-5D index was 94.6. The EQ-5D index of people with low income was lower than that in the high-income group (for people in the rural region: 93.2 v 96.1, P gender, education, marital status, employment, medical insurance, and chronic disease, all the coefficients of the low-income group and high income inequality were significantly negative. After stratifying by income group, all the effects of high income inequality remained negative in both income groups. However, the coefficients of the models in the high income group were not statistically significant. Income inequality has damaging effects on HRQL in Shaanxi, China, especially for people with low income. In addition, people living in rural regions were more vulnerable to economic factors.

  14. Development of an Advanced HPLC–MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma

    Directory of Open Access Journals (Sweden)

    Barbora Hrvolová

    2016-10-01

    Full Text Available The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC-tandem mass spectrometry (MS/MS method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC–MS/MS method led to improvements in the limits of detection (LOD and quantification (LOQ for all analyzed compounds compared to the most often used HPLC–DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids.

  15. Development of an Advanced HPLC–MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma

    Science.gov (United States)

    Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří

    2016-01-01

    The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC–MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC–DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids. PMID:27754400

  16. Multinational consistency of a discrete choice model in quantifying health states for the extended 5-level EQ-5D

    NARCIS (Netherlands)

    Krabbe, P.F.M.; Devlin, N.J.; Stolk, E.A.; Shah, K.K.; Oppe, M.; Van Hout, B.; Quik, E.H.; Pickard, A.S.; Xie, F.

    2013-01-01

    Objectives: To investigate the feasibility of choice experiments for EQ-5D-5L states using computer-based data collection, and to examine the consistency of the estimated parameters values derived after modeling the stated preference data across countries in a multinational study. Methods: Similar

  17. Urinary amino acid analysis: a comparison of iTRAQ-LC-MS/MS, GC-MS, and amino acid analyzer.

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J

    2009-07-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27+/-5.22, 21.18+/-10.94, and 18.34+/-14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39+/-5.35, 6.23+/-3.84, and 35.37+/-29.42. Both GC-MS and iTRAQ-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.

  18. PyMS: a Python toolkit for processing of gas chromatography-mass spectrometry (GC-MS data. Application and comparative study of selected tools

    Directory of Open Access Journals (Sweden)

    O'Callaghan Sean

    2012-05-01

    Full Text Available Abstract Background Gas chromatography–mass spectrometry (GC-MS is a technique frequently used in targeted and non-targeted measurements of metabolites. Most existing software tools for processing of raw instrument GC-MS data tightly integrate data processing methods with graphical user interface facilitating interactive data processing. While interactive processing remains critically important in GC-MS applications, high-throughput studies increasingly dictate the need for command line tools, suitable for scripting of high-throughput, customized processing pipelines. Results PyMS comprises a library of functions for processing of instrument GC-MS data developed in Python. PyMS currently provides a complete set of GC-MS processing functions, including reading of standard data formats (ANDI- MS/NetCDF and JCAMP-DX, noise smoothing, baseline correction, peak detection, peak deconvolution, peak integration, and peak alignment by dynamic programming. A novel common ion single quantitation algorithm allows automated, accurate quantitation of GC-MS electron impact (EI fragmentation spectra when a large number of experiments are being analyzed. PyMS implements parallel processing for by-row and by-column data processing tasks based on Message Passing Interface (MPI, allowing processing to scale on multiple CPUs in distributed computing environments. A set of specifically designed experiments was performed in-house and used to comparatively evaluate the performance of PyMS and three widely used software packages for GC-MS data processing (AMDIS, AnalyzerPro, and XCMS. Conclusions PyMS is a novel software package for the processing of raw GC-MS data, particularly suitable for scripting of customized processing pipelines and for data processing in batch mode. PyMS provides limited graphical capabilities and can be used both for routine data processing and interactive/exploratory data analysis. In real-life GC-MS data processing scenarios PyMS performs

  19. Testing Inflation with Large Scale Structure: Connecting Hopes with Reality

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, Marcello [Univ. of Toronto, ON (Canada); Baldauf, T. [Inst. of Advanced Studies, Princeton, NJ (United States); Bond, J. Richard [Univ. of Toronto, ON (Canada); Canadian Inst. for Advanced Research, Toronto, ON (Canada); Dalal, N. [Univ. of Illinois, Urbana-Champaign, IL (United States); Putter, R. D. [Jet Propulsion Lab., Pasadena, CA (United States); California Inst. of Technology (CalTech), Pasadena, CA (United States); Dore, O. [Jet Propulsion Lab., Pasadena, CA (United States); California Inst. of Technology (CalTech), Pasadena, CA (United States); Green, Daniel [Univ. of Toronto, ON (Canada); Canadian Inst. for Advanced Research, Toronto, ON (Canada); Hirata, Chris [The Ohio State Univ., Columbus, OH (United States); Huang, Zhiqi [Univ. of Toronto, ON (Canada); Huterer, Dragan [Univ. of Michigan, Ann Arbor, MI (United States); Jeong, Donghui [Pennsylvania State Univ., University Park, PA (United States); Johnson, Matthew C. [York Univ., Toronto, ON (Canada); Perimeter Inst., Waterloo, ON (Canada); Krause, Elisabeth [Stanford Univ., CA (United States); Loverde, Marilena [Univ. of Chicago, IL (United States); Meyers, Joel [Univ. of Toronto, ON (Canada); Meeburg, Daniel [Univ. of Toronto, ON (Canada); Senatore, Leonardo [Stanford Univ., CA (United States); Shandera, Sarah [Pennsylvania State Univ., University Park, PA (United States); Silverstein, Eva [Stanford Univ., CA (United States); Slosar, Anze [Brookhaven National Lab. (BNL), Upton, NY (United States); Smith, Kendrick [Perimeter Inst., Waterloo, Toronto, ON (Canada); Zaldarriaga, Matias [Univ. of Toronto, ON (Canada); Assassi, Valentin [Cambridge Univ. (United Kingdom); Braden, Jonathan [Univ. of Toronto, ON (Canada); Hajian, Amir [Univ. of Toronto, ON (Canada); Kobayashi, Takeshi [Perimeter Inst., Waterloo, Toronto, ON (Canada); Univ. of Toronto, ON (Canada); Stein, George [Univ. of Toronto, ON (Canada); Engelen, Alexander van [Univ. of Toronto, ON (Canada)

    2014-12-15

    The statistics of primordial curvature fluctuations are our window into the period of inflation, where these fluctuations were generated. To date, the cosmic microwave background has been the dominant source of information about these perturbations. Large-scale structure is, however, from where drastic improvements should originate. In this paper, we explain the theoretical motivations for pursuing such measurements and the challenges that lie ahead. In particular, we discuss and identify theoretical targets regarding the measurement of primordial non-Gaussianity. We argue that when quantified in terms of the local (equilateral) template amplitude f$loc\\atop{NL}$ (f$eq\\atop{NL}$), natural target levels of sensitivity are Δf$loc, eq\\atop{NL}$ ≃ 1. We highlight that such levels are within reach of future surveys by measuring 2-, 3- and 4-point statistics of the galaxy spatial distribution. This paper summarizes a workshop held at CITA (University of Toronto) on October 23-24, 2014.

  20. Urinary Amino Acid Analysis: A Comparison of iTRAQ®-LC-MS/MS, GC-MS, and Amino Acid Analyzer

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L.; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J.

    2009-01-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. PMID:19481989

  1. Selenium speciation analysis of Misgurnus anguillicaudatus selenoprotein by HPLC-ICP-MS and HPLC-ESI-MS/MS

    Science.gov (United States)

    Analytical methods for selenium (Se) speciation were developed using high performance liquid chromatography (HPLC) coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionization tandem mass spectrometry (ESI-MS/MS). Separations of selenomethionine (Se-Met) and sel...

  2. MassSieve: Panning MS/MS peptide data for proteins

    OpenAIRE

    Slotta, Douglas J.; McFarland, Melinda A.; Markey, Sanford P.

    2010-01-01

    We present MassSieve, a Java-based platform for visualization and parsimony analysis of single and comparative LC-MS/MS database search engine results. The success of mass spectrometric peptide sequence assignment algorithms has led to the need for a tool to merge and evaluate the increasing data set sizes that result from LC-MS/MS-based shotgun proteomic experiments. MassSieve supports reports from multiple search engines with differing search characteristics, which can increase peptide sequ...

  3. EQ-10 electrodeless Z-pinch EUV source for metrology applications

    Science.gov (United States)

    Gustafson, Deborah; Horne, Stephen F.; Partlow, Matthew J.; Besen, Matthew M.; Smith, Donald K.; Blackborow, Paul A.

    2011-11-01

    With EUV Lithography systems shipping, the requirements for highly reliable EUV sources for mask inspection and resist outgassing are becoming better defined, and more urgent. The sources needed for metrology applications are very different than that needed for lithography; brightness (not power) is the key requirement. Suppliers for HVM EUV sources have all resources working on high power and have not entered the smaller market for metrology. Energetiq Technology has been shipping the EQ-10 Electrodeless Z-pinchTM light source since 19951. The source is currently being used for metrology, mask inspection, and resist development2-4. These applications require especially stable performance in both output power and plasma size and position. Over the last 6 years Energetiq has made many source modifications which have included better thermal management to increase the brightness and power of the source. We now have introduced a new source that will meet requirements of some of the mask metrology first generation tools; this source will be reviewed.

  4. Mapping EQ-5D utilities to GBD 2010 and GBD 2013 disability weights: Results of two pilot studies in Belgium

    NARCIS (Netherlands)

    C. Maertens De Noordhout (Charline); B. Devleesschauwer (Brecht); Gielens, L.; Plasmans, M.H.D.; J.A. Haagsma (Juanita); N. Speybroeck (Niko)

    2017-01-01

    textabstractBackground: Utilities and disability weights (DWs) are metrics used for calculating Quality-Adjusted Life Years and Disability-Adjusted Life Years (DALYs), respectively. Utilities can be obtained with multi-attribute instruments such as the EuroQol 5 dimensions questionnaire (EQ-5D). In

  5. Does the EQ-5D capture the effects of physical and mental health status on life satisfaction among older people? A path analysis approach.

    Science.gov (United States)

    Sexton, Eithne; Bennett, Kathleen; Fahey, Tom; Cahir, Caitriona

    2017-05-01

    To examine the extent to which EQ-5D utility scores capture the effect of mental and physical health status on life satisfaction (LS) in older adults. Retrospective cohort study of 884 patients aged ≥70 years from 15 general practices in Ireland, including medical records, pharmacy claims, and self-completion questionnaire. Path analysis was used to evaluate the direct and indirect effects of: (1) chronic disease burden (based on medications data); (2) activity limitation (basic and instrumental activities of daily living); (3) anxiety symptoms and; (4) depressive symptoms (Hospital Anxiety and Depression Scale) on LS (Life Satisfaction Index Z), via a utility score based on responses to the EQ-5D scale. Utility scores were calculated using UK time trade-off utility weights. Covariates included age and socioeconomic status. The final path model fitted the data well (goodness of fit χ 2  = 7.5, df (7), p = 0.37). The direct effects of chronic disease burden and disability on LS were not statistically significant and were excluded from the final model, indicating that EQ-5D score mediated 100% of the total effect on LS. The direct and indirect effects of anxiety and depression on LS were statistically significant, but the size of the indirect effect was small (4% of the total effect for anxiety and 6% of the total effect for depression). The EQ-5D does not adequately capture the effects of anxiety and depression on LS among older adults, suggesting that it may lead to inaccurate assessments of the effectiveness of interventions in this cohort.

  6. Non-aqueous CE-MS of cinchona alkaloids - characterizationof a novel CE-ESI-MS interface

    DEFF Research Database (Denmark)

    Hansen, Frederik André; Hansen, Steen Honoré; Petersen, Nickolaj J.

    We have recently in our group at the University of Copenhagen developed a robust and simple sheatless CE-ESI-MS interface (capillary electrophoresis – electrospray ionization-mass spectrometry). In this presentation the interface is characterized and compared with HPLC-MS for studying...... a submicron fracture in the capillary close the ESI tip. The fracture provides a zero dead volume and excellent conducting properties due to the large amount of ions in the electric double layer. Electric current exceeding the upper limit of CE instrumentation of up to 300 µA can easily be obtained....... Furthermore, the increased conductivity of the buffer in the fracture generates field free pumping of the analytes towards the ESI spray tip. In this study the device was used to analyze the four major alkaloids (diastereomeric pairs of quinine/quinidine and cinchonine/cinchonidine) in Cinchona bark samples...

  7. Organization of GC/MS and LC/MS metabolomics data into chemical libraries

    Directory of Open Access Journals (Sweden)

    DeHaven Corey D

    2010-10-01

    Full Text Available Abstract Background Metabolomics experiments involve generating and comparing small molecule (metabolite profiles from complex mixture samples to identify those metabolites that are modulated in altered states (e.g., disease, drug treatment, toxin exposure. One non-targeted metabolomics approach attempts to identify and interrogate all small molecules in a sample using GC or LC separation followed by MS or MSn detection. Analysis of the resulting large, multifaceted data sets to rapidly and accurately identify the metabolites is a challenging task that relies on the availability of chemical libraries of metabolite spectral signatures. A method for analyzing spectrometry data to identify and Quantify Individual Components in a Sample, (QUICS, enables generation of chemical library entries from known standards and, importantly, from unknown metabolites present in experimental samples but without a corresponding library entry. This method accounts for all ions in a sample spectrum, performs library matches, and allows review of the data to quality check library entries. The QUICS method identifies ions related to any given metabolite by correlating ion data across the complete set of experimental samples, thus revealing subtle spectral trends that may not be evident when viewing individual samples and are likely to be indicative of the presence of one or more otherwise obscured metabolites. Results LC-MS/MS or GC-MS data from 33 liver samples were analyzed simultaneously which exploited the inherent biological diversity of the samples and the largely non-covariant chemical nature of the metabolites when viewed over multiple samples. Ions were partitioned by both retention time (RT and covariance which grouped ions from a single common underlying metabolite. This approach benefitted from using mass, time and intensity data in aggregate over the entire sample set to reject outliers and noise thereby producing higher quality chemical identities. The

  8. SprayQc: a real-time LC-MS/MS quality monitoring system to maximize uptime using off the shelf components.

    Science.gov (United States)

    Scheltema, Richard A; Mann, Matthias

    2012-06-01

    With the advent of high-throughput mass spectrometry (MS)-based proteomics, the magnitude and complexity of the performed experiments has increased dramatically. Likewise, investments in chromatographic and MS instrumentation are a large proportion of the budget of proteomics laboratories. Guarding measurement quality and maximizing uptime of the LC-MS/MS systems therefore requires constant care despite automated workflows. We describe a real-time surveillance system, called SprayQc, that continuously monitors the status of the peripheral equipment to ensure that operational parameters are within an acceptable range. SprayQc is composed of multiple plug-in software components that use computer vision to analyze electrospray conditions, monitor the chromatographic device for stable backpressure, interact with a column oven to control pressure by temperature, and ensure that the mass spectrometer is still acquiring data. Action is taken when a failure condition has been detected, such as stopping the column oven and the LC flow, as well as automatically notifying the appropriate operator. Additionally, all defined metrics can be recorded synchronized on retention time with the MS acquisition file, allowing for later inspection and providing valuable information for optimization. SprayQc has been extensively tested in our laboratory, supports third-party plug-in development, and is freely available for download from http://sourceforge.org/projects/sprayqc .

  9. Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) based bioavailability determination of the major classes of phytochemicals.

    Science.gov (United States)

    Stylos, Evgenios; Chatziathanasiadou, Maria V; Syriopoulou, Aggeliki; Tzakos, Andreas G

    2017-03-15

    Natural products derived from plants have served as an inexhausted source for drug discovery and drug development. They have been evolutionary amplified with drug-like properties and have already illustrated immense therapeutic potential over an array of different diseases. However, their incorporation in the drug discovery pipeline has been diminished the last two decades. This was probably due to barriers related to their inherent difficulties to be integrated in high-throughput screening assays as also their largely unexplored bioavailability. Analytical procedures have come into the spotlight, a result of the continuous development of the instrumentation's capabilities as far as detection and separation is concerned. Integral part of this technological evolution is LC-MS instrumentation and its extended use for the determination of various compounds. The fact that it provides extra sensitivity, specificity and good separation in complex samples, makes LC-MS/MS the ultimate tool in the determination of many types of chemical compounds, such as phytochemicals. Herein, we focus on the achievements of the last five years in quantitative analysis of the major classes of phytochemicals (flavonoids, alkaloids, terpenes, glycosides and saponins) in plasma, through LC-MS/MS, as also their bioavailability. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Controle biológico de ciatostomíneos de eqüinos resistentes a ivermectina e pamoato de pirantel com o fungo Monacrosporium thaumasium

    OpenAIRE

    Tavela, Alexandre de Oliveira

    2010-01-01

    A viabilidade de uma formulação do fungo predador de nematóides Monacrosporium thaumasium foi avaliada no controle biológico de ciatostomíneos de eqüinos. Dois grupos (tratado com o fungo e controle) constituídos por seis éguas em cada grupo, mestiças, com idade entre 2,5 a 3,5 anos, foram colocados em pastagens de Cynodon sp. naturalmente infectadas com larvas de ciatostomíneos de eqüinos. No grupo tratado, cada animal recebeu 1g/10 kg de peso corporal (0,2g/10kg de peso vivo de fungo) de pé...

  11. Analysis of inorganic and organic constituents of myrrh resin by GC–MS and ICP-MS: An emphasis on medicinal assets

    Directory of Open Access Journals (Sweden)

    Syed Rizwan Ahamad

    2017-07-01

    Full Text Available The aim of the present investigation was to explore the constituents of the Arabian myrrh resin obtained from Commiphora myrrha. The organic and inorganic composition of the myrrh gum resin has been investigated using gas chromatography-mass spectrometry (GC–MS and inductively coupled plasma-mass spectrometry (ICP-MS. Analysis executed by ICP-MS reveals the presence of various inorganic elements in significant amount in the myrrh resin. The elements that were found to be present in large amounts include calcium, magnesium, aluminum, phosphorus, chlorine, chromium, bromine and scandium. The important organic constituents identified in the myrrh ethanolic extract include limonene, curzerene, germacrene B, isocericenine, myrcenol, beta selinene, and spathulenol,. The present work complements other myrrh associated investigations done in the past and provides additional data for the future researches.

  12. Analysis of inorganic and organic constituents of myrrh resin by GC-MS and ICP-MS: An emphasis on medicinal assets.

    Science.gov (United States)

    Ahamad, Syed Rizwan; Al-Ghadeer, Abdul Rahman; Ali, Raisuddin; Qamar, Wajhul; Aljarboa, Suliman

    2017-07-01

    The aim of the present investigation was to explore the constituents of the Arabian myrrh resin obtained from Commiphora myrrha. The organic and inorganic composition of the myrrh gum resin has been investigated using gas chromatography-mass spectrometry (GC-MS) and inductively coupled plasma-mass spectrometry (ICP-MS). Analysis executed by ICP-MS reveals the presence of various inorganic elements in significant amount in the myrrh resin. The elements that were found to be present in large amounts include calcium, magnesium, aluminum, phosphorus, chlorine, chromium, bromine and scandium. The important organic constituents identified in the myrrh ethanolic extract include limonene, curzerene, germacrene B, isocericenine, myrcenol, beta selinene, and spathulenol,. The present work complements other myrrh associated investigations done in the past and provides additional data for the future researches.

  13. Rapid Quantification of Abscisic Acid by GC-MS/MS for Studies of Abiotic Stress Response.

    Science.gov (United States)

    Verslues, Paul E

    2017-01-01

    Drought and low water potential induce large increases in Abscisic Acid (ABA ) content of plant tissue. This increased ABA content is essential to regulate downstream stress resistance responses; however, the mechanisms regulating ABA accumulation are incompletely known. Thus, the ability to accurately quantify ABA at high throughput and low cost is important for plant stress research. We have combined and modified several previously published protocols to establish a rapid ABA analysis protocol using gas chromatography-tandem mass spectrometry (GC-MS/MS). Derivatization of ABA is performed with (trimethylsilyl)-diazomethane rather than the harder to prepare diazomethane. Sensitivity of the analysis is sufficient that small samples of low water potential treated Arabidopsis thaliana seedlings can be routinely analyzed in reverse genetic studies of putative stress regulators as well as studies of natural variation in ABA accumulation.

  14. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Area Donate Donate Search v What Is MS? Definition of MS What Causes MS? Who Gets MS? ... Support Personal Stories d What Is MS? d Definition of MS Myelin Immune-Mediated Disease T Cells ...

  15. Metabolic profiling of roots of liquorice (Glycyrrhiza glabra) from different geographical areas by ESI/MS/MS and determination of major metabolites by LC-ESI/MS and LC-ESI/MS/MS.

    Science.gov (United States)

    Montoro, Paola; Maldini, Mariateresa; Russo, Mariateresa; Postorino, Santo; Piacente, Sonia; Pizza, Cosimo

    2011-02-20

    Liquid chromatography electrospray mass spectrometry (LC-ESI/MS) has been applied to the full characterization of saponins and phenolics in hydroalcoholic extracts of roots of liquorice (Glycyrrhiza glabra). Relative quantitative analyses of the samples with respect to the phenolic constituents and to a group of saponins related to glycyrrhizic acid were performed using LC-ESI/MS. For the saponin constituents, full scan LC-MS/MS fragmentation of the protonated (positive ion mode) or deprotonated (negative ion mode) molecular species generated diagnostic fragment ions that provided information concerning the triterpene skeleton and the number and nature of the substituents. On the basis of the specific fragmentation of glycyrrhizic acid, an LC-MS/MS method was developed in order to quantify the analyte in the liquorice root samples. Chinese G. glabra roots contained the highest levels of glycyrrhizic acid, followed by those from Italy (Calabria). Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Absence of diarrhoea in equidae treated with oxytetracycline/ Ausência de diarréia em eqüídeos medicados com oxitetraciclina

    Directory of Open Access Journals (Sweden)

    Júlio Augusto Naylor Lisbôa

    2004-05-01

    Full Text Available Evaluation and observation was carried out with 24 equidae put on oxytetracycline hydrochloride medication, a drug incriminated as potential cause of severe colitis with diarrhea manifestations for this species. The animals of this study were natural carriers of affections that required antimicrobial use. During 4 to 19 uninterrupted days intravenous doses of 7, 15 or 20mg/kg were administered, every 24 hours. No side effects were observed during the period of treatment or after it. Thus, at the doses and intervals described above, oxytetracycline showed to be safe for equidae.Foram avaliados e acompanhados 24 eqüídeos medicados com cloridrato de oxitetraciclina, fármaco incriminado como potencial causador de colite severa com manifestação de diarréia nesta espécie. Os eqüídeos estudados eram portadores naturais de afecções que requeriam o emprego de antimicrobianos. Administraram-se doses de 7, 15 ou 20mg/kg, a cada 24 horas, por via intravenosa, durante 4 a até 19 dias seguidos. Não se observou qualquer efeito colateral aparente durante o período de tratamento e após o seu término. A oxitetraciclina mostrou-se, portanto, segura para os eqüídeos, nas doses e intervalo entre doses utilizados.

  17. Eficácia de pamoato de pirantel, isolado ou associado ao triclorfon, no controle de ciatostomíneos de eqüinos

    Directory of Open Access Journals (Sweden)

    Marcelo de Campos Pereira

    1994-12-01

    Full Text Available Através de estudo comparativo, objetivou-se avaliar a eficiência anti-helmíntica de pamoato de pirantel, isolado ou associado ao triclorfon, no controle de estrongilídeos de eqüinos da raça Puro Sangue Inglês. As coproculturas realizadas antes e após os tratamentos levaram consistentemente ao encontro de populações puras de ciatostomíneos com oito células intestinais. As reduções de ovos por grama de fezes foram avaliadas do 7º. ao 45º. dias pós-tratamento. Comparando os valores médios de OPG dos eqüinos tratados com pamoato de pirantel (13,2 mg/kg associado ao triclorfon (30 mg/kg e com pamoato de pirantel isolado (13,2 mg/kg, observou-se diferença não significante (P≤0,05 ao longo do experimento, verificando-se, 7 dias após o tratamento, reduções médias de OPG de quase 100% e, do 7º. ao 20º. dias, reduções ainda superiores a 90%. Os resultados indicam que os dois produtos são eficazes na redução de ovos por grama de fezes de ciatostomíneos de eqüinos mantidos sob condições a campo.

  18. Evaluation of preparation methods for MS-based analysis of intestinal epithelial cell proteomes

    DEFF Research Database (Denmark)

    Hesselager, Marianne Overgaard; Codrea, Marius Cosmin; Bendixen, Emøke

    2015-01-01

    analyzed by LC and electrospray QTOF-MS. The methods were evaluated according to efficiency, purity, transmembrane protein recovery, as well as for suitability to large-scale preparations. Our data clearly demonstrate that mucosal shaving is by far the best-suited method for in-depth MS analysis in terms...... are low in abundance, and large amounts of sample is needed for their preparation and for undertaking MS-based analysis. The aim of this study was to evaluate three different methods for isolation and preparation of pig intestinal epithelial cells for MS-based analysis of the proteome. Samples were...... of ease and speed of sample preparation, as well as protein recovery. In comparison, more gentle methods where intestinal epithelial cells are harvested by shaking are more time consuming, result in lower protein yield, and are prone to increased technical variation due to multiple steps involved....

  19. Spectral trees as a robust annotation tool in LC–MS based metabolomics

    NARCIS (Netherlands)

    Hooft, van der J.J.J.; Vervoort, J.J.M.; Bino, R.J.; Vos, de C.H.

    2012-01-01

    The identification of large series of metabolites detectable by mass spectrometry (MS) in crude extracts is a challenging task. In order to test and apply the so-called multistage mass spectrometry (MS n ) spectral tree approach as tool in metabolite identification in complex sample extracts, we

  20. Validation of the large-scale Lagrangian cirrus model CLaMS-Ice by in-situ measurements

    Science.gov (United States)

    Costa, Anja; Rolf, Christian; Grooß, Jens-Uwe; Afchine, Armin; Spelten, Nicole; Dreiling, Volker; Zöger, Martin; Krämer, Martina

    2015-04-01

    Cirrus clouds are an element of uncertainty in the climate system and have received increasing attention since the last IPCC reports. The interaction of varying freezing meachanisms, sedimentation rates, temperature and updraft velocity fluctuations and other factors that lead to the formation of those clouds is still not fully understood. During the ML-Cirrus campaign 2014 (Germany), the new cirrus cloud model CLaMS-Ice (see Rolf et al., EGU 2015) has been used for flight planning to direct the research aircraft HALO into interesting cirrus cloud regions. Now, after the campaign, we use our in-situ aircraft measurements to validate and improve this model - with the long-term goal to enable it to simulate cirrus cloud cover globally, with reasonable computing times and sufficient accuracy. CLaMS-Ice consists of a two-moment bulk model established by Spichtinger and Gierens (2009a, 2009b), which simulates cirrus clouds along trajectories that the Lagrangian model CLaMS (McKenna et al., 2002 and Konopka et al. 2007) derived from ECMWF data. The model output covers temperature, pressure, relative humidity, ice water content (IWC), and ice crystal numbers (Nice). These parameters were measured on board of HALO by the following instruments: temperature and pressure by BAHAMAS, total and gas phase water by the hygrometers FISH and SHARC (see Meyer et al 2014, submitted to ACP), and Nice as well as ice crystal size distributions by the cloud spectrometer NIXE-CAPS (see also Krämer et al., EGU 2015). Comparisons of the model results with the measurements yield that cirrus clouds can be successfully simulated by CLaMS-Ice. However, there are sections in which the model's relative humidity and Nice deviate considerably from the measured values. This can be traced back to e.g. the initialization of total water from ECMWF data. The simulations are therefore reinitiated with the total water content measured by FISH. Other possible sources of uncertainties are investigated, as

  1. LFQuant: a label-free fast quantitative analysis tool for high-resolution LC-MS/MS proteomics data.

    Science.gov (United States)

    Zhang, Wei; Zhang, Jiyang; Xu, Changming; Li, Ning; Liu, Hui; Ma, Jie; Zhu, Yunping; Xie, Hongwei

    2012-12-01

    Database searching based methods for label-free quantification aim to reconstruct the peptide extracted ion chromatogram based on the identification information, which can limit the search space and thus make the data processing much faster. The random effect of the MS/MS sampling can be remedied by cross-assignment among different runs. Here, we present a new label-free fast quantitative analysis tool, LFQuant, for high-resolution LC-MS/MS proteomics data based on database searching. It is designed to accept raw data in two common formats (mzXML and Thermo RAW), and database search results from mainstream tools (MASCOT, SEQUEST, and X!Tandem), as input data. LFQuant can handle large-scale label-free data with fractionation such as SDS-PAGE and 2D LC. It is easy to use and provides handy user interfaces for data loading, parameter setting, quantitative analysis, and quantitative data visualization. LFQuant was compared with two common quantification software packages, MaxQuant and IDEAL-Q, on the replication data set and the UPS1 standard data set. The results show that LFQuant performs better than them in terms of both precision and accuracy, and consumes significantly less processing time. LFQuant is freely available under the GNU General Public License v3.0 at http://sourceforge.net/projects/lfquant/. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Patient Characteristics Impacting Health State Index Scores, Measured by the EQ-5D of Females with Stress Urinary Incontinence Symptoms

    NARCIS (Netherlands)

    Tincello, Douglas; Sculpher, Mark; Tunn, Ralf; Quail, Deborah; van der Vaart, Huub; Falconer, Christian; Manning, Martina; Timlin, Louise

    2010-01-01

    Objective: To describe the characteristics of women seeking treatment for symptoms of stress urinary incontinence (SUI) and to investigate the association of SUI symptoms with generic health-related quality of life (HRQoL) as measured by the EuroQol (EQ-5D) instrument. Methods: The Stress Urinary

  3. Contribution to the risk characterization of ciguatoxins: LOAEL estimated from eight ciguatera fish poisoning events in Guadeloupe (French West Indies)

    Energy Technology Data Exchange (ETDEWEB)

    Hossen, Virginie [Université Paris-Est, ANSES-Laboratory for Food Safety, National Reference Laboratory for the Control of Marine biotoxins, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort (France); Soliño, Lucia [Institut de Recerca i Tecnologia Agroalimentàries (IRTA), Ctra. Poble Nou km 5.5, Sant Carles de la Rapita (Spain); Leroy, Patricia [Université Paris-Est, ANSES-Laboratory for Food Safety, National Reference Laboratory for the Control of Marine biotoxins, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort (France); David, Eric [Ministry of Agriculture, Direction de l’Alimentation de l’Agriculture et de la Forêt de Guadeloupe, Abymes (France); Velge, Pierre [Ministry of Agriculture, General Directorate for Food, Paris (France); Dragacci, Sylviane, E-mail: Sylviane.dragacci@anses.fr [Université Paris-Est, ANSES-Laboratory for Food Safety, National Reference Laboratory for the Control of Marine biotoxins, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort (France); Krys, Sophie [Université Paris-Est, ANSES-Laboratory for Food Safety, National Reference Laboratory for the Control of Marine biotoxins, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort (France); Flores Quintana, Harold [U.S. Food and Drug Administration (FDA), Division of Seafood Science and Technology, Gulf Coast Seafood Laboratory, 1 Iberville Drive, Dauphin Island, AL 36528 (United States); Diogène, Jorge [Institut de Recerca i Tecnologia Agroalimentàries (IRTA), Ctra. Poble Nou km 5.5, Sant Carles de la Rapita (Spain)

    2015-11-15

    From 2010 to 2012, 35 ciguatera fish poisoning (CFP) events involving 87 individuals who consumed locally-caught fish were reported in Guadeloupe (French West Indies). For 12 of these events, the presence of ciguatoxins (CTXs) was indicated in meal remnants and in uncooked fish by the mouse bioassay (MBA). Caribbean ciguatoxins (C-CTXs) were confirmed by liquid chromatography–tandem mass spectrometry (LC–MS/MS) analysis. Using a cell-based assay (CBA), and the only available standard Pacific ciguatoxin-1 (P-CTX-1), the lowest toxins level detected in fish samples causing CFP was 0.022 µg P-CTX-1 equivalent (eq.)·kg{sup −1} fish. Epidemiological and consumption data were compiled for most of the individuals afflicted, and complete data for establishing the lowest observable adverse effects level (LOAEL) were obtained from 8 CFP events involving 21 individuals. Based on toxin intakes, the LOAEL was estimated at 4.2 ng P-CTX-1 eq./individual corresponding to 48.4 pg P-CTX-1 eq. kg{sup −1} body weight (bw). Although based on limited data, these results are consistent with the conclusions of the European Food Safety Authority (EFSA) opinion which indicates that a level of 0.01 µg P-CTX-1 eq. kg{sup −1} fish, regardless of source, should not exert effects in sensitive individuals when consuming a single meal. The calculated LOAEL is also consistent with the U.S. Food and Drug Administration guidance levels for CTXs (0.1 µg C-CTX-1 eq. kg{sup −1} and 0.01 µg P-CTX-1 eq. kg{sup −1} fish). - Highlights: • We report on an epidemiological study on Ciguatera events in the French West Indies. • The collection of consumption data allows for the first time the LOAEL determination. • The LOAEL for ciguatoxins was established at 48.4 pg P-CTX-1 eq. kg{sup −1} bw. • LC–MS/MS provided structural confirmation of C-CTX1 in two suspected samples • Neuro-2A CBA is suitable for assessing composite toxicity levels in fish samples.

  4. Analysis of poly-beta-hydroxybutyrate in environmental samples by GC-MS/MS.

    Science.gov (United States)

    Elhottová, D; Tríska, J; Petersen, S O; Santrůcková, H

    2000-05-01

    Application of gas chromatography-mass spectrometry (GC-MS) can significantly improve trace analyses of compounds in complex matrices from natural environments compared to gas chromatography only. A GC-MS/MS technique for determination of poly-beta-hydroxybutyrate (PHB), a bacterial storage compound, has been developed and used for analysis of two soils stored for up to 319 d, fresh samples of sewage sludge, as well as a pure culture of Bacillus megaterium. Specific derivatization of beta-hydroxybutyrate (3-OH C4:0) PHB monomer units by N-tert-butyl-dimethylsilyl-N-methyltrifluoracetamide (MTBSTFA) improved chromatographic and mass spectrometric properties of the analyte. The diagnostic fragmentation scheme of the derivates tert-butyldimethylsilyl ester and ether of beta-hydroxybutyric acid (MTBSTFA-HB) essential for the PHB identification was shown. The ion trap MS was used, therefore the scan gave the best sensitivity and with MS/MS the noise decreased, so the S/N was better and also with second fragmentation the amount of ions increased compared to SIM. The detection limit for MTBSTFA-HB by GC-MS/MS was about 10(-13) g microL(-1) of injected volume, while by GC (FID) and GC-MS (scan) it was around 10(-10) g microL(-1) of injected volume. Sensitivity of GC-MS/MS measurements of PHB in arable soil and activated sludge samples was down to 10 pg of PHB g(-1) dry matter. Comparison of MTBSTFA-HB detection in natural soil sample by GC (FID), GC-MS (scan) and by GC-MS/MS demonstrated potentials and limitations of the individual measurement techniques.

  5. Multisteroid LC–MS/MS assay for glucocorticoids and androgens and its application in Addison's disease

    Science.gov (United States)

    Methlie, Paal; Hustad, Steinar; Kellman, Ralf; Almås, Bjørg; Erichsen, Martina M; Husebye, Eystein S; Løvås, Kristian

    2013-01-01

    Objective Liquid chromatography–tandem mass spectrometry (LC–MS/MS) offers superior analytical specificity compared with immunoassays, but it is not available in many regions and hospitals due to expensive instrumentation and tedious sample preparation. Thus, we developed an automated, high-throughput LC–MS/MS assay for simultaneous quantification of ten endogenous and synthetic steroids targeting diseases of the hypothalamic–pituitary–adrenal axis and gonads. Methods Deuterated internal standards were added to 85 μl serum and processed by liquid–liquid extraction. Cortisol, cortisone, prednisolone, prednisone, 11-deoxycortisol, dexamethasone, testosterone, androstenedione and progesterone were resolved by ultra-high-pressure chromatography on a reversed-phase column in 6.1 min and detected by triple-quadrupole mass spectrometry. The method was used to assess steroid profiles in women with Addison's disease (AD, n=156) and blood donors (BDs, n=102). Results Precisions ranged from 4.5 to 10.1% relative standard deviations (RSD), accuracies from 95 to 108% and extraction recoveries from 60 to 84%. The method was practically free of matrix effects and robust to individual differences in serum composition. Most postmenopausal AD women had extremely low androstenedione concentrations, below 0.14 nmol/l, and median testosterone concentrations of 0.15 nmol/l (interquartile range 0.00–0.41), considerably lower than those of postmenopausal BDs (1.28 nmol/l (0.96–1.64) and 0.65 nmol/l (0.56–1.10) respectively). AD women in fertile years had androstenedione concentrations of 1.18 nmol/l (0.71–1.76) and testosterone concentrations of 0.44 nmol/l (0.22–0.63), approximately half of those found in BDs of corresponding age. Conclusion This LC–MS/MS assay provides highly sensitive and specific assessments of glucocorticoids and androgens with low sample volumes and is suitable for endocrine laboratories and research. Its utility has been

  6. Hemogasometria em eqüinos com compactação experimental do cólon maior tratados com sene, fluidoterapia enteral e parenteral

    OpenAIRE

    Ribeiro Filho,José Dantas; Abreu,José Mário Girão; Alves,Geraldo Eleno Silveira; Dantas,Waleska de Melo Ferreira

    2007-01-01

    O equilíbrio ácido-base foi estudado em eqüinos com compactação experimental do cólon maior após o uso de solução isotônica poliônica enteral, sene mais hidratação intravenosa e hidratação intravenosa. As amostras sangüíneas foram colhidas de 20 animais, quatro grupos (E8, RL, SE e C) de cinco animais cada. Os animais dos grupos tratados eram portadores de compactação no cólon maior induzida experimentalmente. Eqüinos no grupo E8 receberam solução isotônica poliônica enteral (8mL kg-1 h-1 48h...

  7. Pesquisa em saúde, política de saúde e eqüidade na América Latina

    Directory of Open Access Journals (Sweden)

    Alberto Pellegrini Filho

    2004-06-01

    Full Text Available O autor analisa as relações entre pesquisa de saúde, políticas de saúde e eqüidade na América Latina. Descreve novas tendências no modo de produção do conhecimento, que permitem maior integração entre as necessidades sociais e a pesquisa, facilitando o vínculo entre esta e o processo de definição de políticas. Analisa as manifestações das novas tendências na América Latina e finaliza com a descrição de algumas iniciativas promovidas pela OPAS no sentido de aproveitar as oportunidades abertas pelas novas tendências para a melhoria das condições de saúde na região. Busca defender a tese de que a informação e o conhecimento são bens públicos essenciais e que as iniqüidades de acesso a esses bens são importantes determinantes das iniqüidades em saúde. Para que as políticas de saúde e as políticas de pesquisa em saúde se integrem e se consolidem como políticas públicas voltadas a atender ao interesse público e à promoção da eqüidade, é necessário o fortalecimento do processo democrático de definição das mesmas, multiplicando os atores envolvidos, os espaços e oportunidades de interação entre eles e instrumentando sua participação com o acesso eqüitativo a informações e conhecimentos científicos pertinentes que permitam a defesa fundamentada de seus interesses.

  8. Improvements in the EQ-10 electrodeless Z-pinch EUV source for metrology applications

    Science.gov (United States)

    Horne, Stephen F.; Gustafson, Deborah; Partlow, Matthew J.; Besen, Matthew M.; Smith, Donald K.; Blackborow, Paul A.

    2011-04-01

    Now that EUV lithography systems are beginning to ship into the fabs for next generation chips it is more critical that the EUV infrastructure developments are keeping pace. Energetiq Technology has been shipping the EQ-10 Electrodeless Z-pinch™ light source since 2005. The source is currently being used for metrology, mask inspection, and resist development. These applications require especially stable performance in both power and source size. Over the last 5 years Energetiq has made many source modifications which have included better thermal management as well as high pulse rate operation6. Recently we have further increased the system power handling and electrical pulse reproducibility. The impact of these modifications on source performance will be reported.

  9. Development of the GC-MS organic aerosol monitor (GC-MS OAM) for in-field detection of particulate organic compounds

    Science.gov (United States)

    Cropper, Paul M.; Overson, Devon K.; Cary, Robert A.; Eatough, Delbert J.; Chow, Judith C.; Hansen, Jaron C.

    2017-11-01

    Particulate matter (PM) is among the most harmful air pollutants to human health, but due to its complex chemical composition is poorly characterized. A large fraction of PM is composed of organic compounds, but these compounds are not regularly monitored due to limitations in current sampling and analysis techniques. The Organic Aerosol Monitor (GC-MS OAM) combines a collection device with thermal desorption, gas chromatography and mass spectrometry to quantitatively measure the carbonaceous components of PM on an hourly averaged basis. The GC-MS OAM is fully automated and has been successfully deployed in the field. It uses a chemically deactivated filter for collection followed by thermal desorption and GC-MS analysis. Laboratory tests show that detection limits range from 0.2 to 3 ng for 16 atmospherically relevant compounds, with the possibility for hundreds more. The GC-MS OAM was deployed in the field for semi-continuous measurement of the organic markers, levoglucosan, dehydroabietic acid, and polycyclic aromatic hydrocarbons (PAHs) from January to March 2015. Results illustrate the significance of this monitoring technique to characterize the organic components of PM and identify sources of pollution.

  10. Quantification of menadione from plasma and urine by a novel cysteamine-derivatization based UPLC-MS/MS method.

    Science.gov (United States)

    Yuan, Teng-Fei; Wang, Shao-Ting; Li, Yan

    2017-09-15

    Menadione, as the crucial component of vitamin Ks, possessed significant nutritional and clinical values. However, there was still lack of favourable quantification strategies for it to date. For improvement, a novel cysteamine derivatization based UPLC-MS/MS method was presented in this work. The derivatizating reaction was proved non-toxic, easy-handling and high-efficient, which realized the MS detection of menadione under positive mode. Benefitting from the excellent sensitivity of the derivatizating product as well as the introduction of the stable isotope dilution technique, the quantification could be achieved in the range of 0.05-50.0ng/mL for plasma and urine matrixes with satisfied accuracy and precision. After analysis of the samples from healthy volunteers after oral administration of menadione sodium bisulfite tablets, the urinary free menadione was quantified for the very first time. We believe the progress in this work could largely promote the exploration of the metabolic mechanism of vitamin K in vivo. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Cannabinoids determination in oral fluid by SPME-GC/MS and UHPLC-MS/MS and its application on suspected drivers.

    Science.gov (United States)

    Anzillotti, Luca; Castrignanò, Erika; Strano Rossi, Sabina; Chiarotti, Marcello

    2014-12-01

    The confirmation of Δ9-tetrahydrocannabinol (THC) in oral fluid (OF) is an important issue for assessing Driving Under the Influence of Drugs (DUID). The aim of this research was to develop a highly sensitive method with minimal sample pre-treatment suitable for the analysis of small OF volumes (100 μL) for the confirmation of cannabinoids in DUID cases. Two methods were compared for the confirmation of THC in residual OF samples, obtained from a preliminary on-site screening with commercial devices. An ultra high performance LC-MS (UHPLC-MS/MS) method and an SPME-GC/MS method were hence developed. 100 μL of the residual mixture OF/preservative buffer or neat OF was simply added to 10 μL of THC-D3 (1 μg/mL) and submitted to the two different analyses: A - direct injection of 10 μL in UHPLC-MS/MS in positive electrospray ionisation (ESI) mode and B - sampling for 30 min with SPME (100 μm polydimethylsiloxane or PDMS fibre) and direct injection by desorption of the fibre in the GC injection port. The lowest limit of detection (LLOD) of THC was 2 ng/mL in UHPLC-MS/MS and 0.5 ng/mL in SPME-GC/MS. In addition, cannabidiol (CBD) and cannabinol (CBN) could be detected in GC/MS equipment at 2 ng/mL, whilst in UHPLC-MS/MS the LLOD was 20 ng/mL. Both methods were applied to 70 samples coming from roadside tests. By SPME-GC/MS analysis, THC was confirmed in 42 samples, whilst CBD was detected in 21 of them, along with CBN in 14 samples. THC concentrations ranged from traces below the lowest limit of quantification or LLOQ (2 ng/mL) up to 690 ng/mL. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Software ion scan functions in analysis of glycomic and lipidomic MS/MS datasets.

    Science.gov (United States)

    Haramija, Marko

    2018-03-01

    Hardware ion scan functions unique to tandem mass spectrometry (MS/MS) mode of data acquisition, such as precursor ion scan (PIS) and neutral loss scan (NLS), are important for selective extraction of key structural data from complex MS/MS spectra. However, their software counterparts, software ion scan (SIS) functions, are still not regularly available. Software ion scan functions can be easily coded for additional functionalities, such as software multiple precursor ion scan, software no ion scan, and software variable ion scan functions. These are often necessary, since they allow more efficient analysis of complex MS/MS datasets, often encountered in glycomics and lipidomics. Software ion scan functions can be easily coded by using modern script languages and can be independent of instrument manufacturer. Here we demonstrate the utility of SIS functions on a medium-size glycomic MS/MS dataset. Knowledge of sample properties, as well as of diagnostic and conditional diagnostic ions crucial for data analysis, was needed. Based on the tables constructed with the output data from the SIS functions performed, a detailed analysis of a complex MS/MS glycomic dataset could be carried out in a quick, accurate, and efficient manner. Glycomic research is progressing slowly, and with respect to the MS experiments, one of the key obstacles for moving forward is the lack of appropriate bioinformatic tools necessary for fast analysis of glycomic MS/MS datasets. Adding novel SIS functionalities to the glycomic MS/MS toolbox has a potential to significantly speed up the glycomic data analysis process. Similar tools are useful for analysis of lipidomic MS/MS datasets as well, as will be discussed briefly. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Determination of the glycation sites of Bacillus anthracis neoglycoconjugate vaccine by MALDI-TOF/TOF-CID-MS/MS and LC-ESI-QqTOF-tandem mass spectrometry

    Science.gov (United States)

    Jahouh, Farid; Hou, Shu-jie; Kováč, Pavol; Banoub, Joseph H.

    2012-01-01

    We present herein an efficient mass spectrometric method for the localization of the glycation sites of a model neoglycoconjugate vaccine formed by a construct of the tetrasaccharide side chain of the Bacillus anthracis exosporium and the protein carrier bovine serum albumin. The glycoconjugate was digested with both trypsin and GluC V8 endoproteinases, and the digests were then analyzed by MALDI-TOF/TOF-CID-MS/MS and nano-LC-ESI-QqTOF-CID-MS/MS. The sequences of the unknown peptides analyzed by MALDI-TOF/TOF-CID-MS/MS, following digestion with the GluC V8 endoproteinase, allowed us to recognize three glycopeptides whose glycation occupancies were, respectively, on Lys 235, Lys 420, and Lys 498. Similarly, the same analysis was performed on the tryptic digests, which permitted us to recognize two glycation sites on Lys 100 and Lys 374. In addition, we have also used LC-ESI-QqTOF-CID-MS/MS analysis for the identification of the tryptic digests. However, this analysis identified a higher number of glycopeptides than would be expected from a glycoconjugate composed of a carbohydrate–protein ratio of 5.4:1, which would have resulted in glycation occupancies of 18 specific sites. This discrepancy was due to the large number of glycoforms formed during the synthetic carbohydrate–spacer–carrier protein conjugation. Likewise, the LC-ESI-QqTOF-MS/MS analysis of the GluC V8 digest also identified 17 different glycation sites on the synthetic glycoconjugate. PMID:22012665

  14. Analytical Method Details (MS): SE52_MS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available stem and Waters Q-Tof Premier UPLC-QTOF-MS ESI Negative The eluates (3 μl) were subsequently subjected to metabolome...DS column (LC-ESI-Q-Tof/MS, HPLC: Waters Acquity UPLC system; MS: Waters Q-Tof Premier). The metabolome...d (Matsuda et al., 2009c, 2010a). Briefly, the metabolome data were obtained in the negative ion mode (m/z 1... the complex nature of the metabolome data. To construct MS2T libraries, the extracts of five ecotypes were

  15. Information-dependent acquisition-mediated LC-MS/MS screening procedure with semiquantitative potential.

    Science.gov (United States)

    Decaestecker, Tineke N; Vande Casteele, Sofie R; Wallemacq, Pierre E; Van Peteghem, Carlos H; Defore, Dieter L; Van Bocxlaer, Jan F

    2004-11-01

    The development of a LC-MS/MS general unknown screening procedure for toxicologically relevant substances in blood samples by means of information-dependent acquisition on a Q-TOF is reported. IDA is an artificial intelligence-based product ion scan mode providing automatic "on-the-fly" MS to MS/MS switching. By performing information-dependent scanning at two different fragmentation energies, two collision-induced dissociation product ion spectra for each of the detected compounds are generated. As such, information-rich MS/MS spectra are obtained from precursor ions not known beforehand. In addition, limitation of the MS/MS acquisition time to an acceptable minimum resulted in an almost instantaneous switch back to the MS mode. As such, this approach provided MS chromatograms that still could be of use for semiquantitative purposes. Since the switching intensity threshold, unequivocally related to the background noise, proved a critical parameter, the solid-phase extraction procedure, the liquid chromatographic conditions, and the mass spectrometric parameters all were optimized to the advantage of information-dependent acquisition. Finally, the screening procedure we developed was benchmarked, on one hand, qualitatively against the results obtained from traditional GUS approaches in a number of routine toxicological laboratories (20 samples) and, on the other hand, quantitatively with respect to its potential against established LC-MS/MS methods (7 samples). The procedure performed very well from a qualitative point of view; almost all of the drugs detected by the conventional techniques were identified, as well as additional drugs that were not previously reported. The procedure proved well-suited for an initial semiquantitative assessment, as is customary in, for example, forensic toxicology before accurate intoxication levels are determined using targeted analytical analyses.

  16. Do generic utility measures capture what is important to the quality of life of people with multiple sclerosis?

    Science.gov (United States)

    Kuspinar, Ayse; Mayo, Nancy E

    2013-04-25

    %) and mood (11%). The SF-6D included the most number of domains (6 domains) important to people with MS, followed by the EQ-5D (4 domains) and the HUI2 (4 domains) and then the HUI3 (3 domains). The mean and standard deviation (SD) for the PGI, EQ-5D and the SF-6D were 0.50 (SD 0.25), 0.69 (0.18) and 0.69 (0.13), respectively. The magnitude of difference between the PGI and the generic utility measures was large and statistically significant. Although the generic utility measures included certain items that were important to people with MS, there were several that were missing. An important consequence of this mismatch was that values of QOL derived from the PGI were importantly and significantly lower than those estimated using any of the generic utility measures. This could have a substantial impact in evaluating the effect of interventions for people with MS.

  17. Guide to data preparation for EQ3/6 (Wolery) modified for the IBM 3033

    International Nuclear Information System (INIS)

    Noy, D.J.

    1981-11-01

    The ability to predict mineral-fluid equilibria is an important aspect of geochemical research into radioactive waste disposal. The interaction of ground waters and waste leachates with the host rock of a disposal site, either at elevated or ambient temperatures, will influence the performance of the disposal system. The EQ3/6 package (Wolery, 1979) provides a technique for the prediction of such interactions using available thermodynamic data, and for extrapolating laboratory experimental data on rock-fluid equilibria. This report describes the modifications performed on this package to allow operation on an IBM machine, and is intended as a guide to data preparation for the programmes. (author)

  18. Improving N-Glycan Coverage using HPLC-MS with Electrospray Ionization at Subambient Pressure

    Energy Technology Data Exchange (ETDEWEB)

    Marginean, Ioan; Kronewitter, Scott R.; Moore, Ronald J.; Slysz, Gordon W.; Monroe, Matthew E.; Anderson, Gordon A.; Tang, Keqi; Smith, Richard D.

    2012-10-01

    Human serum glycan profiling with mass spectrometry (MS) has been employed to study several disease conditions and is demonstrating promise for e.g. clinical biomarker discovery. However, the poor glycan ionization efficiency and the large dynamic range of glycan concentrations in human sera hinder comprehensive profiling. In particular, large glycans are problematic because they are present at low concentrations and prone to fragmentation. Here we show that the sub-ambient pressure ionization with nanoelectrospray (SPIN)-MS can expand the serum glycome profile when compared with the conventional atmospheric pressure electrospray ionization (ESI)-MS with a heated capillary inlet. Notably, the ions generated by the SPIN interface were observed at higher charge states for 50% of the annotated glycans. Out of a total of 130 detected glycans, 34 were only detected with the SPIN-MS, resulting in improved coverage of glycan families as well as of glycans with larger numbers of labile monosaccharides.

  19. Automated protein identification by the combination of MALDI MS and MS/MS spectra from different instruments.

    Science.gov (United States)

    Levander, Fredrik; James, Peter

    2005-01-01

    The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.

  20. Molecular analysis of intact preen waxes of Calidris Canutus (Aves: Scolopacidae) by GC/MS and GC/MS/MS

    NARCIS (Netherlands)

    Sinninghe Damsté, J.S.; Dekker, M.H.A.; Piersma, T.

    2000-01-01

    The intact preen wax esters of the red knot Calidris canutus were studied with gas chromatography/mass spectrometry (GC/MS) and GC/MS/MS. In this latter technique, transitions from the molecular ion to fragment ions representing the fatty acid moiety of the wax esters were measured, providing

  1. ENIGMATIC RECURRENT PULSATIONAL VARIABILITY OF THE ACCRETING WHITE DWARF EQ LYN (SDSS J074531.92+453829.6)

    Energy Technology Data Exchange (ETDEWEB)

    Mukadam, Anjum S.; Szkody, Paula [Department of Astronomy, University of Washington, Seattle, WA 98195-1580 (United States); Townsley, D. M.; Brockett, T. [Department of Physics and Astronomy, University of Alabama, Tuscaloosa, AL 35487 (United States); Gaensicke, B. T.; Parsons, S. [Department of Physics, University of Warwick, Coventry CV4 7AL (United Kingdom); Southworth, J. [Astrophysics Group, Keele University, Staffordshire ST5 5BG (United Kingdom); Hermes, J. J.; Montgomery, M. H.; Winget, D. E.; Harrold, S. [Department of Astronomy, University of Texas at Austin, Austin, TX 78759 (United States); Tovmassian, G.; Zharikov, S. [Observatorio Astronomico Nacional SPM, Instituto de Astronomia, Universidad Nacional Autonoma de Mexico, Ensenada, BC (Mexico); Drake, A. J. [Department of Astronomy and the Center for Advanced Computing Research, California Institute of Technology, Pasadena, CA 91225 (United States); Henden, A. [American Association of Variable Star Observers, 25 Birch Street, Cambridge, MA 02138 (United States); Rodriguez-Gil, P. [Departamento de Astrofisica, Universidad de La Laguna, La Laguna, E-38204 Santa Cruz de Tenerife (Spain); Sion, E. M. [Department of Astronomy and Astrophysics, Villanova University, Villanova, PA 19085 (United States); Zola, S.; Szymanski, T. [Astronomical Observatory, Jagiellonian University, ul. Orla 171, PL-30-244 Krakow (Poland); Pavlenko, E. [Crimean Astrophysical Observatory, Crimea 98409 (Ukraine); and others

    2013-09-15

    Photometric observations of the cataclysmic variable EQ Lyn (SDSS J074531.92+453829.6), acquired from 2005 October to 2006 January, revealed high-amplitude variability in the range 1166-1290 s. This accreting white dwarf underwent an outburst in 2006 October, during which its brightness increased by at least five magnitudes, and it started exhibiting superhumps in its light curve. Upon cooling to quiescence, the superhumps disappeared and it displayed the same periods in 2010 February as prior to the outburst within the uncertainties of a couple of seconds. This behavior suggests that the observed variability is likely due to nonradial pulsations in the white dwarf star, whose core structure has not been significantly affected by the outburst. The enigmatic observations begin with an absence of pulsational variability during a multi-site campaign conducted in 2011 January-February without any evidence of a new outburst; the light curve is instead dominated by superhumps with periods in the range of 83-87 minutes. Ultraviolet Hubble Space Telescope time-series spectroscopy acquired in 2011 March reveals an effective temperature of 15,400 K, placing EQ Lyn within the broad instability strip of 10,500-16,000 K for accreting pulsators. The ultraviolet light curve with 90% flux from the white dwarf shows no evidence of any pulsations. Optical photometry acquired during 2011 and Spring 2012 continues to reflect the presence of superhumps and an absence of pulsations. Subsequent observations acquired in 2012 December and 2013 January finally indicate the disappearance of superhumps and the return of pulsational variability with similar periods as previous data. However, our most recent data from 2013 March to May reveal superhumps yet again with no sign of pulsations. We speculate that this enigmatic post-outburst behavior of the frequent disappearance of pulsational variability in EQ Lyn is caused either by heating the white dwarf beyond the instability strip due to an

  2. Establishing utility values for the 22-item Sino-Nasal Outcome Test (SNOT-22) using a crosswalk to the EuroQol-five-dimensional questionnaire-three-level version (EQ-5D-3L).

    Science.gov (United States)

    Crump, R Trafford; Lai, Ernest; Liu, Guiping; Janjua, Arif; Sutherland, Jason M

    2017-05-01

    Chronic rhinosinusitis (CRS) is a common condition for which there are numerous medical and surgical treatments. The 22-item Sino-Nasal Outcome Test (SNOT-22) is a patient-reported outcome measure often used with patients diagnosed with CRS. However, there are no utility values associated with the SNOT-22, limiting its use in comparative effectiveness research. The purpose of this study was to establish utilities for the SNOT-22 by mapping responses to utility values associated with the EuroQol-5-dimensional questionnaire-3-level version (EQ-5D-3L). This study used data collected from patients diagnosed with CRS awaiting bilateral endoscopic sinus surgery in Vancouver, Canada. Study participants completed both the SNOT-22 and the EQ-5D-3L. Ordinary least squares was used for 3 models that estimated the EQ-5D-3L utility values as a function of the SNOT-22 items. A total of 232 participants completed both the SNOT-22 and the EQ-5D-3L. As expected, there was a negative relationship between the SNOT-22 global scores and EQ-5D-3L utility values. Adjusted R 2 for the 3 models ranged from 0.28 to 0.33, and root mean squared errors between 0.23 and 0.24. A nonparametric bootstrap analysis demonstrated robustness of the findings. This study successfully developed a mapping model to associate utility values with responses to the SNOT-22. This model could be used to conduct comparative effectiveness research in CRS to evaluate the various interventions available for treating this condition. © 2017 ARS-AAOA, LLC.

  3. Do country-specific preference weights matter in the choice of mapping algorithms? The case of mapping the Diabetes-39 onto eight country-specific EQ-5D-5L value sets.

    Science.gov (United States)

    Lamu, Admassu N; Chen, Gang; Gamst-Klaussen, Thor; Olsen, Jan Abel

    2018-03-22

    To develop mapping algorithms that transform Diabetes-39 (D-39) scores onto EQ-5D-5L utility values for each of eight recently published country-specific EQ-5D-5L value sets, and to compare mapping functions across the EQ-5D-5L value sets. Data include 924 individuals with self-reported diabetes from six countries. The D-39 dimensions, age and gender were used as potential predictors for EQ-5D-5L utilities, which were scored using value sets from eight countries (England, Netherland, Spain, Canada, Uruguay, China, Japan and Korea). Ordinary least squares, generalised linear model, beta binomial regression, fractional regression, MM estimation and censored least absolute deviation were used to estimate the mapping algorithms. The optimal algorithm for each country-specific value set was primarily selected based on normalised root mean square error (NRMSE), normalised mean absolute error (NMAE) and adjusted-r 2 . Cross-validation with fivefold approach was conducted to test the generalizability of each model. The fractional regression model with loglog as a link function consistently performed best in all country-specific value sets. For instance, the NRMSE (0.1282) and NMAE (0.0914) were the lowest, while adjusted-r 2 was the highest (52.5%) when the English value set was considered. Among D-39 dimensions, the energy and mobility was the only one that was consistently significant for all models. The D-39 can be mapped onto the EQ-5D-5L utilities with good predictive accuracy. The fractional regression model, which is appropriate for handling bounded outcomes, outperformed other candidate methods in all country-specific value sets. However, the regression coefficients differed reflecting preference heterogeneity across countries.

  4. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Definition of MS Myelin Immune-Mediated Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters ... d Research News & Progress Research News MSPARIS2017 Stem Cells in MS Progressive MS Research Clinical Trials in ...

  5. Eqüidade em saúde: uma análise crítica de conceitos Health equity: a critical analysis of concepts

    Directory of Open Access Journals (Sweden)

    Ligia Maria Vieira-da-Silva

    2009-01-01

    Full Text Available A eqüidade em saúde tem sido estudada principalmente a partir de uma perspectiva epidemiológica e pouca atenção tem sido dada às questões conceituais. Em grande parte dos estudos revisados, a eqüidade tem sido utilizada como sinônimo de igualdade, e seu oposto, a iniqüidade, como sinônimo de desigualdade. As tentativas de melhor precisar seus significados têm sido, em boa parte, descritivas, com lacunas no que diz respeito à discussão das relações entre eqüidade em saúde, justiça e o processo de determinação social da saúde-doença. Neste ensaio, pretendemos analisar criticamente a série significante diversidade, diferença, desigualdade, iniqüidade, distinção no que concerne à produção da saúde-doença-cuidado em grupos sociais e suas possibilidades de articulação a uma teoria social da saúde. Nesse percurso, estaremos apoiados, por um lado, no conceito de Perelman de eqüidade e em alguns dos argumentos de Heller sobre a justiça e, por outro lado, na sociologia das práticas de Bourdieu, com o objetivo de melhor desenvolver esses conceitos, procurando discutir implicações para a formulação de políticas públicas no campo da saúde.Health inequalities have been studied mainly from an epidemiological perspective, with limited attention to conceptual issues. The terms "equity" and "equality" have often been used as synonyms, as have their opposites, "inequity" and "inequality". The few attempts to establish their meanings have been either purely descriptive or have failed to add to an understanding of the underlying dynamics in health-disease-related phenomena. The present essay explores the semantic series that includes difference, diversity, distinction, inequality, and inequity and its relationship to health phenomena in light of Perelman's concept of equity, Bourdieu's sociology, and some arguments in Heller's theory of justice, with the aim of contributing to the development of these concepts, while

  6. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... MS Relapsing-remitting MS (RRMS) Share this page Facebook Twitter Email Relapsing-remitting MS (RRMS) Relapsing-remitting ... Here Start Here Colophon Stay Informed Join Us Facebook Twitter LinkedIn YouTube Pinterest MS Connection About the ...

  7. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... d Living Well with MS d Diet, Exercise & Healthy Behaviors Diet & Nutrition Exercise Heat & Temperature Sensitivity Sleep Vaccinations Women's Health Unhealthy Habits Managing MS and Another Condition Aging with MS Anesthesia and Surgery Managing Your MS ...

  8. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... to navigation Skip to content Menu Navigation National Multiple Sclerosis Society Sign In In Your Area Donate Donate ... of MS What Causes MS? Who Gets MS? Multiple Sclerosis FAQs Types of MS Related Conditions Symptoms & Diagnosis ...

  9. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Relapsing-remitting MS (RRMS) Share this page Facebook Twitter Email Relapsing-remitting MS (RRMS) Relapsing-remitting MS ( ... Start Here Colophon Stay Informed Join Us Facebook Twitter LinkedIn YouTube Pinterest MS Connection About the Society ...

  10. Pitiose cutânea em eqüinos: 14 casos Cutaneous pythiosis in horses: 14 cases

    Directory of Open Access Journals (Sweden)

    Eliza Simone Viegas Sallis

    2003-10-01

    Full Text Available A pitiose cutânea é uma doença crônica que afeta preferencialmente eqüinos e, raramente, bovinos, caninos, felinos e seres humanos. É causada por Pythium insidiosum, um fungo aquático. São relatados quatorze casos de pitiose cutânea em eqüinos do município de Uruguaiana, Rio Grande do Sul. As lesões se localizam, principalmente na região distal dos membros pélvicos e caracterizam-se macroscopicamente por granulomas subcutâneos, ulcerados com exsudação sero-sanguinolenta. Microscopicamente há áreas irregulares de necrose circundadas por infiltrado inflamatório constituído por eosinófilos, neutrófilos, macrófagos e abundante tecido fibrovascular. São descritos e discutidos os métodos de diagnóstico, sinais clínicos, achados de necropsia, histopatologia, diagnóstico diferencial e tratamentoCutaneous pythiosis is a chronic condition that may be fatal if early therapy is not implemented. It affects mainly horses and rarely cattle, dogs, cats and human beings. It is caused by Pythium insidiosum, which infects wounds on the skin of ventral abdomen, distal limbs and head of animals which pasture and drink water in swamped land. This report includes fourteen cases of pythiosis in horses from Uruguaiana, in the state of Rio Grande do Sul, Brazil. Methods of diagnosis and treatment are described and discussed.

  11. Comparison of the Multiattribute Utility Instruments EQ-5D and SF-6D in a Europe-Wide Population-Based Cohort of Patients with Inflammatory Bowel Disease 10 Years after Diagnosis.

    Science.gov (United States)

    Huppertz-Hauss, Gert; Aas, Eline; Lie Høivik, Marte; Langholz, Ebbe; Odes, Selwyn; Småstuen, Milada; Stockbrugger, Reinhold; Hoff, Geir; Moum, Bjørn; Bernklev, Tomm

    2016-01-01

    Background. The treatment of chronic inflammatory bowel disease (IBD) is costly, and limited resources call for analyses of the cost effectiveness of therapeutic interventions. The present study evaluated the equivalency of the Short Form 6D (SF-6D) and the Euro QoL (EQ-5D), two preference-based HRQoL instruments that are broadly used in cost-effectiveness analyses, in an unselected IBD patient population. Methods. IBD patients from seven European countries were invited to a follow-up visit ten years after their initial diagnosis. Clinical and demographic data were assessed, and the Short Form 36 (SF-36) was employed. Utility scores were obtained by calculating the SF-6D index values from the SF-36 data for comparison with the scores obtained with the EQ-5D questionnaire. Results. The SF-6D and EQ-5D provided good sensitivities for detecting disease activity-dependent utility differences. However, the single-measure intraclass correlation coefficient was 0.58, and the Bland-Altman plot indicated numerous values beyond the limits of agreement. Conclusions. There was poor agreement between the measures retrieved from the EQ-5D and the SF-6D utility instruments. Although both instruments may provide good sensitivity for the detection of disease activity-dependent utility differences, the instruments cannot be used interchangeably. Cost-utility analyses performed with only one utility instrument must be interpreted with caution.

  12. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... the Challenges of MS You CAN! Webcasts DVDs Books For Kids: Keep S'myelin Información en Español Brochures ... Managing MS and Another Condition Aging with MS Anesthesia and Surgery Managing Your MS d Emotional Well- ...

  13. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... the Challenges of MS You CAN! Webcasts DVDs Books For Kids: Keep S'myelin Información en Español Brochures ... MS Managing MS Resources for You and Your Practice Publications for Clinicians Publications for Your Patients MS ...

  14. Measuring health-related quality of life in women with endometriosis: comparing the clinimetric properties of the Endometriosis Health Profile-5 (EHP-5) and the EuroQol-5D (EQ-5D).

    Science.gov (United States)

    Aubry, G; Panel, P; Thiollier, G; Huchon, C; Fauconnier, A

    2017-06-01

    Which of the Endometriosis Health Profile-5 (EHP-5) and the EuroQol-5D (EQ-5D) is the most efficient to assess quality of life in women suffering from endometriosis? Although EHP-5 and EQ-5D instruments had an excellent responsiveness, EHP-5 has a better discriminative ability than EQ-5 to measure health-related quality of life (HrQoL). Proper measurement of HrQoL is important in endometriosis. While many quality of life instruments are available, few have been completely validated in endometriosis. The EHP-5 and the EQ-5D are short and practical scales, which may be useful. Literature is lacking to determine which one is the most suitable in clinical practice or in clinical research. This prospective and observational study conducted between 1 January 2012 and 31 December 2013 included a total of 253 consecutive women with proven endometriosis, undergoing medical or surgical treatment, in 2 French tertiary care centers. Women over 18 years consulting for painful symptoms of at least 3 months' duration or for infertility, with endometriosis proven histologically or radiologically, were requested to fill in the 2 scales before (T0) and 12 months after treatment (T1). Construct validity consisted in testing presupposed relationships between the scales and the characteristics of the patients or the endometriosis. Responsiveness to change was calculated for all patients and in each treatment group. Effect sizes were used according to Cohen's d method. A total of 216 women filled in completely all the questionnaires at T0 and 133 (61.6%) at T1. EHP-5 and EQ-5D had good discriminative abilities regarding the patients' symptoms, with significant superiority of EHP-5 concerning three of the nine hypotheses. The largest difference was that calculated for the 'intensity of dysmenorrhea' using the Visual Analogic Scale, with respectively effect size from Cohen's d (ES) = 0.86 95% CI (0.54-1.17) for EHP-5 versus 0.48 95% CI (0.16-0.79) for EQ-5D. There were no differences in

  15. pDeep: Predicting MS/MS Spectra of Peptides with Deep Learning.

    Science.gov (United States)

    Zhou, Xie-Xuan; Zeng, Wen-Feng; Chi, Hao; Luo, Chunjie; Liu, Chao; Zhan, Jianfeng; He, Si-Min; Zhang, Zhifei

    2017-12-05

    In tandem mass spectrometry (MS/MS)-based proteomics, search engines rely on comparison between an experimental MS/MS spectrum and the theoretical spectra of the candidate peptides. Hence, accurate prediction of the theoretical spectra of peptides appears to be particularly important. Here, we present pDeep, a deep neural network-based model for the spectrum prediction of peptides. Using the bidirectional long short-term memory (BiLSTM), pDeep can predict higher-energy collisional dissociation, electron-transfer dissociation, and electron-transfer and higher-energy collision dissociation MS/MS spectra of peptides with >0.9 median Pearson correlation coefficients. Further, we showed that intermediate layer of the neural network could reveal physicochemical properties of amino acids, for example the similarities of fragmentation behaviors between amino acids. We also showed the potential of pDeep to distinguish extremely similar peptides (peptides that contain isobaric amino acids, for example, GG = N, AG = Q, or even I = L), which were very difficult to distinguish using traditional search engines.

  16. Integration of the metal ion charge neutralization model for humic acid complexation into the geochemical speciation code EQ3/6

    International Nuclear Information System (INIS)

    Brendler, V.

    2002-01-01

    Geochemical modeling often requires the consideration of humics as major complexing agent and colloid. The metal ion charge neutralization model can handle respective interactions and has therefore been integrated into the speciation software EQ3/6. An application showing the influence of the pH-dependence of the loading capacity on actinide speciation is given. (orig.)

  17. Ferro-based derivatizing agents for LC/MS an LC/EC/MS

    NARCIS (Netherlands)

    Seiwert, Bettina

    2007-01-01

    Within this thesis, the development and application of ferrocene-based derivatizing agents for LC/MS and LC/EC/MS is presented. The advantages of derivatization by ferrocenes are the similtaneous introduction of a mass tag and an electroactive group, which make them ideally suited for LC/MS and

  18. A Coherent vorticity preserving eddy-viscosity correction for Large-Eddy Simulation

    Science.gov (United States)

    Chapelier, J.-B.; Wasistho, B.; Scalo, C.

    2018-04-01

    This paper introduces a new approach to Large-Eddy Simulation (LES) where subgrid-scale (SGS) dissipation is applied proportionally to the degree of local spectral broadening, hence mitigated or deactivated in regions dominated by large-scale and/or laminar vortical motion. The proposed coherent-vorticity preserving (CvP) LES methodology is based on the evaluation of the ratio of the test-filtered to resolved (or grid-filtered) enstrophy, σ. Values of σ close to 1 indicate low sub-test-filter turbulent activity, justifying local deactivation of the SGS dissipation. The intensity of the SGS dissipation is progressively increased for σ activated in developed turbulence characterized by σ ≤σeq, where the value σeq is derived assuming a Kolmogorov spectrum. The proposed approach can be applied to any eddy-viscosity model, is algorithmically simple and computationally inexpensive. LES of Taylor-Green vortex breakdown demonstrates that the CvP methodology improves the performance of traditional, non-dynamic dissipative SGS models, capturing the peak of total turbulent kinetic energy dissipation during transition. Similar accuracy is obtained by adopting Germano's dynamic procedure albeit at more than twice the computational overhead. A CvP-LES of a pair of unstable periodic helical vortices is shown to predict accurately the experimentally observed growth rate using coarse resolutions. The ability of the CvP methodology to dynamically sort the coherent, large-scale motion from the smaller, broadband scales during transition is demonstrated via flow visualizations. LES of compressible channel are carried out and show a good match with a reference DNS.

  19. Mapping health assessment questionnaire disability index (HAQ-DI) score, pain visual analog scale (VAS), and disease activity score in 28 joints (DAS28) onto the EuroQol-5D (EQ-5D) utility score with the KORean Observational study Network for Arthritis (KORONA) registry data.

    Science.gov (United States)

    Kim, Hye-Lin; Kim, Dam; Jang, Eun Jin; Lee, Min-Young; Song, Hyun Jin; Park, Sun-Young; Cho, Soo-Kyung; Sung, Yoon-Kyoung; Choi, Chan-Bum; Won, Soyoung; Bang, So-Young; Cha, Hoon-Suk; Choe, Jung-Yoon; Chung, Won Tae; Hong, Seung-Jae; Jun, Jae-Bum; Kim, Jinseok; Kim, Seong-Kyu; Kim, Tae-Hwan; Kim, Tae-Jong; Koh, Eunmi; Lee, Hwajeong; Lee, Hye-Soon; Lee, Jisoo; Lee, Shin-Seok; Lee, Sung Won; Park, Sung-Hoon; Shim, Seung-Cheol; Yoo, Dae-Hyun; Yoon, Bo Young; Bae, Sang-Cheol; Lee, Eui-Kyung

    2016-04-01

    The aim of this study was to estimate the mapping model for EuroQol-5D (EQ-5D) utility values using the health assessment questionnaire disability index (HAQ-DI), pain visual analog scale (VAS), and disease activity score in 28 joints (DAS28) in a large, nationwide cohort of rheumatoid arthritis (RA) patients in Korea. The KORean Observational study Network for Arthritis (KORONA) registry data on 3557 patients with RA were used. Data were randomly divided into a modeling set (80 % of the data) and a validation set (20 % of the data). The ordinary least squares (OLS), Tobit, and two-part model methods were employed to construct a model to map to the EQ-5D index. Using a combination of HAQ-DI, pain VAS, and DAS28, four model versions were examined. To evaluate the predictive accuracy of the models, the root-mean-square error (RMSE) and mean absolute error (MAE) were calculated using the validation dataset. A model that included HAQ-DI, pain VAS, and DAS28 produced the highest adjusted R (2) as well as the lowest Akaike information criterion, RMSE, and MAE, regardless of the statistical methods used in modeling set. The mapping equation of the OLS method is given as EQ-5D = 0.95-0.21 × HAQ-DI-0.24 × pain VAS/100-0.01 × DAS28 (adjusted R (2) = 57.6 %, RMSE = 0.1654 and MAE = 0.1222). Also in the validation set, the RMSE and MAE were shown to be the smallest. The model with HAQ-DI, pain VAS, and DAS28 showed the best performance, and this mapping model enabled the estimation of an EQ-5D value for RA patients in whom utility values have not been measured.

  20. Application of CE-ICP-MS and CE-ESI-MS/MS for identification of Zn-binding ligands in Goji berries extracts.

    Science.gov (United States)

    Ruzik, Lena; Kwiatkowski, Piotr

    2018-06-01

    The identification of groups of ligands binding metals is a crucial issue for the better understanding of their bioaccessibility. In the current study, we have intended an approach for identification of Zn-binding ligands based on using capillary electrophoresis combined with inductively coupled plasma mass spectrometry (CE-ICP-MS) and tandem electrospray ionization mass spectrometry (CE-ESI-MS/MS). The approach, which featured the use of the coupling of capillary electrophoresis with inductively coupled plasma mass spectrometry allows to separate and observe zinc ions present in complexes with respect to their size and charge and to identify nine compounds with zinc isotopic profile. CE-ICP-MS provides us with information about presence of zinc species and elemental information about zinc distribution. CE-ESI-MS/MS provide us with information about the most favorable Zn binding ligands: amino acids, flavonols, stilbenoids, fenolic acids and carotenoids. The presented work is the continuation of previous studies based on using LC-ESI-MS/MS, though, now we presented a new solutions with the possibility of changing detectors without changing the separation techniques, what is important without re-optimizing the method. The new presented method allows to identify the zinc-binding ligands in shorter time. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Analysis of pesticide residues in strawberries and soils by GC-MS/MS, LC-MS/MS and two-dimensional GC-time-of-flight MS comparing organic and integrated pest management farming.

    Science.gov (United States)

    Fernandes, Virgínia C; Lehotay, Steven J; Geis-Asteggiante, Lucía; Kwon, Hyeyoung; Mol, Hans G J; van der Kamp, Henk; Mateus, Nuno; Domingues, Valentina F; Delerue-Matos, Cristina

    2014-01-01

    This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 µg kg(-1) for fluazifop-p-butyl to 50 µg kg(-1) for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits.

  2. Quantitative Determination of Perfluorochemicals and Fluorotelomer Alcohols in Plants from Biosolid-Amended Fields using LC/MS/MS and GC/MS

    Science.gov (United States)

    Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...

  3. Probabilistic mapping of descriptive health status responses onto health state utilities using Bayesian networks: an empirical analysis converting SF-12 into EQ-5D utility index in a national US sample.

    Science.gov (United States)

    Le, Quang A; Doctor, Jason N

    2011-05-01

    As quality-adjusted life years have become the standard metric in health economic evaluations, mapping health-profile or disease-specific measures onto preference-based measures to obtain quality-adjusted life years has become a solution when health utilities are not directly available. However, current mapping methods are limited due to their predictive validity, reliability, and/or other methodological issues. We employ probability theory together with a graphical model, called a Bayesian network, to convert health-profile measures into preference-based measures and to compare the results to those estimated with current mapping methods. A sample of 19,678 adults who completed both the 12-item Short Form Health Survey (SF-12v2) and EuroQoL 5D (EQ-5D) questionnaires from the 2003 Medical Expenditure Panel Survey was split into training and validation sets. Bayesian networks were constructed to explore the probabilistic relationships between each EQ-5D domain and 12 items of the SF-12v2. The EQ-5D utility scores were estimated on the basis of the predicted probability of each response level of the 5 EQ-5D domains obtained from the Bayesian inference process using the following methods: Monte Carlo simulation, expected utility, and most-likely probability. Results were then compared with current mapping methods including multinomial logistic regression, ordinary least squares, and censored least absolute deviations. The Bayesian networks consistently outperformed other mapping models in the overall sample (mean absolute error=0.077, mean square error=0.013, and R overall=0.802), in different age groups, number of chronic conditions, and ranges of the EQ-5D index. Bayesian networks provide a new robust and natural approach to map health status responses into health utility measures for health economic evaluations.

  4. In Vivo Metabolism Study of Xiamenmycin A in Mouse Plasma by UPLC-QTOF-MS and LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Feng Lei

    2015-01-01

    Full Text Available Xiamenmycin A is an antifibrotic leading compound with a benzopyran skeleton that is isolated from mangrove-derived Streptomyces xiamenensis. As a promising small molecule for fibrotic diseases, less information is known about its metabolic characteristics in vivo. In this study, the time-course of xiamenmycin A in mouse plasma was investigated by relative quantification. After two types of administration of xiamenmycin A at a single dose of 10 mg/kg, the plasma concentrations were measured quantitatively by LC-MS/MS. The dynamic changes in the xiamenmycin A concentration showed rapid absorption and quick elimination in plasma post-administration. Four metabolites (M1–M4 were identified in blood by UPLC-QTOF-MS, and xiamenmycin B (M3 is the principal metabolite in vivo, as verified by comparison of the authentic standard sample. The structures of other metabolites were identified based on the characteristics of their MS and MS/MS data. The newly identified metabolites are useful for understanding the metabolism of xiamenmycin A in vivo, aiming at the development of an anti-fibrotic drug candidate for the therapeutic treatment of excessive fibrotic diseases.

  5. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Become an MS Activist Take Action Current Advocacy Issues Advocacy Results Advocacy News d Raise Awareness d ... MS are more likely to experience gradually worsening problems with walking and mobility, along with whatever other symptoms they may have. Diagnosing relapsing-remitting MS (RRMS) Learn More Learn More ... Room MS Prevalence ...

  6. A large-strain radial consolidation theory for soft clays improved by vertical drains

    OpenAIRE

    Geng, X; Yu, H-S

    2017-01-01

    A system of vertical drains with combined vacuum and surcharge preloading is an effective solution for promoting radial flow, accelerating consolidation. However, when a mixture of soil and water is deposited at a low initial density, a significant amount of deformation or surface settlement occurs. Therefore, it is necessary to introduce large-strain theory, which has been widely used to manage dredged disposal sites in one-dimensional theory, into radial consolidation theory. A governing eq...

  7. Characterization, stoichiometry, and stability of salivary protein-tannin complexes by ESI-MS and ESI-MS/MS.

    Science.gov (United States)

    Canon, Francis; Paté, Franck; Meudec, Emmanuelle; Marlin, Thérèse; Cheynier, Véronique; Giuliani, Alexandre; Sarni-Manchado, Pascale

    2009-12-01

    Numerous protein-polyphenol interactions occur in biological and food domains particularly involving proline-rich proteins, which are representative of the intrinsically unstructured protein group (IUP). Noncovalent protein-ligand complexes are readily detected by electrospray ionization mass spectrometry (ESI-MS), which also gives access to ligand binding stoichiometry. Surprisingly, the study of interactions between polyphenolic molecules and proteins is still an area where ESI-MS has poorly benefited, whereas it has been extensively applied to the detection of noncovalent complexes. Electrospray ionization mass spectrometry has been applied to the detection and the characterization of the complexes formed between tannins and a human salivary proline-rich protein (PRP), namely IB5. The study of the complex stability was achieved by low-energy collision-induced dissociation (CID) measurements, which are commonly implemented using triple quadrupole, hybrid quadrupole time-of-flight, or ion trap instruments. Complexes composed of IB5 bound to a model polyphenol EgCG have been detected by ESI-MS and further analyzed by MS/MS. Mild ESI interface conditions allowed us to observe intact noncovalent PRP-tannin complexes with stoichiometries ranging from 1:1 to 1:5. Thus, ESI-MS shows its efficiency for (1) the study of PRP-tannin interactions, (2) the determination of stoichiometry, and (3) the study of complex stability. We were able to establish unambiguously both their stoichiometries and their overall subunit architecture via tandem mass spectrometry and solution disruption experiments. Our results prove that IB5.EgCG complexes are maintained intact in the gas phase.

  8. An improved method of sample preparation on AnchorChip targets for MALDI-MS and MS/MS and its application in the liver proteome project

    DEFF Research Database (Denmark)

    Zhang, Xumin; Shi, Liang; Shu, Shaokung

    2007-01-01

    An improved method for sample preparation for MALDI-MS and MS/MS using AnchorChip targets is presented. The method, termed the SMW method (sample, matrix wash), results in better sensitivity for peptide mass fingerprinting as well as for sequencing by MS/MS than previously published methods. The ...

  9. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants

    Directory of Open Access Journals (Sweden)

    Carolina Salazar

    2012-07-01

    Full Text Available In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the

  10. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants.

    Science.gov (United States)

    Salazar, Carolina; Armenta, Jenny M; Shulaev, Vladimir

    2012-07-06

    In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The

  11. Comparison of the Multiattribute Utility Instruments EQ-5D and SF-6D in a Europe-Wide Population-Based Cohort of Patients with Inflammatory Bowel Disease 10 Years after Diagnosis

    Directory of Open Access Journals (Sweden)

    Gert Huppertz-Hauss

    2016-01-01

    Full Text Available Background. The treatment of chronic inflammatory bowel disease (IBD is costly, and limited resources call for analyses of the cost effectiveness of therapeutic interventions. The present study evaluated the equivalency of the Short Form 6D (SF-6D and the Euro QoL (EQ-5D, two preference-based HRQoL instruments that are broadly used in cost-effectiveness analyses, in an unselected IBD patient population. Methods. IBD patients from seven European countries were invited to a follow-up visit ten years after their initial diagnosis. Clinical and demographic data were assessed, and the Short Form 36 (SF-36 was employed. Utility scores were obtained by calculating the SF-6D index values from the SF-36 data for comparison with the scores obtained with the EQ-5D questionnaire. Results. The SF-6D and EQ-5D provided good sensitivities for detecting disease activity-dependent utility differences. However, the single-measure intraclass correlation coefficient was 0.58, and the Bland-Altman plot indicated numerous values beyond the limits of agreement. Conclusions. There was poor agreement between the measures retrieved from the EQ-5D and the SF-6D utility instruments. Although both instruments may provide good sensitivity for the detection of disease activity-dependent utility differences, the instruments cannot be used interchangeably. Cost-utility analyses performed with only one utility instrument must be interpreted with caution.

  12. Phylogenetic analysis of the MS4A and TMEM176 gene families.

    Directory of Open Access Journals (Sweden)

    Jonathan Zuccolo

    2010-02-01

    Full Text Available The MS4A gene family in humans includes CD20 (MS4A1, FcRbeta (MS4A2, Htm4 (MS4A3, and at least 13 other syntenic genes encoding membrane proteins, most having characteristic tetraspanning topology. Expression of MS4A genes is variable in tissues throughout the body; however, several are limited to cells in the hematopoietic system where they have known roles in immune cell functions. Genes in the small TMEM176 group share significant sequence similarity with MS4A genes and there is evidence of immune function of at least one of the encoded proteins. In this study, we examined the evolutionary history of the MS4A/TMEM176 families as well as tissue expression of the phylogenetically earliest members, in order to investigate their possible origins in immune cells.Orthologs of human MS4A genes were found only in mammals; however, MS4A gene homologs were found in most jawed vertebrates. TMEM176 genes were found only in mammals and bony fish. Several unusual MS4A genes having 2 or more tandem MS4A sequences were identified in the chicken (Gallus gallus and early mammals (opossum, Monodelphis domestica and platypus, Ornithorhyncus anatinus. A large number of highly conserved MS4A and TMEM176 genes was found in zebrafish (Danio rerio. The most primitive organism identified to have MS4A genes was spiny dogfish (Squalus acanthus. Tissue expression of MS4A genes in S. acanthias and D. rerio showed no evidence of expression restricted to the hematopoietic system.Our findings suggest that MS4A genes first appeared in cartilaginous fish with expression outside of the immune system, and have since diversified in many species into their modern forms with expression and function in both immune and nonimmune cells.

  13. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... for You and Your Practice Publications for Clinicians Publications for Your Patients MS Navigator Program Programs and Services for Your Patients ... Relapsing-remitting MS (RRMS) Relapsing-remitting MS ( ...

  14. The use of the EQ-5D-Y health related quality of life outcome measure in children in the Western Cape, South Africa: psychometric properties, feasibility and usefulness - a longitudinal, analytical study.

    Science.gov (United States)

    Scott, Des; Ferguson, Gillian D; Jelsma, Jennifer

    2017-01-19

    The EQ-5D-Y, an outcome measure of Health Related Quality of Life (HRQoL) in children, was developed by an international task team in 2010. The multinational feasibility, reliability and validity study which followed was undertaken with mainly healthy children. The aim of this study was to investigate the psychometric properties of the EQ-5D-Y when used to assess the HRQoL of children with different health states. A sample of 224 children between eight and twelve years were grouped according to their health state. The groups included 52 acutely ill children, 67 children with either a chronic health condition or disability and 105 mostly healthy, mainstream school children as a comparator. They were assessed at baseline, at three months and at six months. An analysis of the psychometric properties was performed to assess the reliability, validity and responsiveness of the EQ-5D-Y in the different groups of children. Cohen's kappa, the intraclass correlation coefficient, Pearson Chi-square, Kruskal-Wallis ANOVA and effect size of Wilcoxon Signed-rank test were used to determine the reliability, validity and responsiveness of the instrument. The EQ-5D-Y dimensions were found to be reliable on test-retest (kappa varying from 0.365 to 0.653), except for the Usual Activities dimension (kappa 0.199). The Visual Analogue Scale (VAS) was also reliable (ICC = 0.77). Post-hoc analysis indicated that dimensions were able to discriminate between acutely ill and healthy children (all differences p Wilcoxon Signed-rank test for VAS was 0.43). Six of the nine therapists who took part in the study, found the measure quick and easy to apply, used the information in the management of the child and would continue to use it in future. The EQ-5D-Y could be used with confidence as an outcome measure for acutely-ill children, but demonstrated poorer psychometric properties in children with no health condition or chronic conditions. It appears to be feasible and useful to include the

  15. Applications of MALDI-TOF MS to large-scale human mtDNA population-based studies

    Czech Academy of Sciences Publication Activity Database

    Cerezo, M.; Černý, Viktor; Carracedo, Á.; Salas, A.

    2009-01-01

    Roč. 30, č. 21 (2009), s. 3665-3673 ISSN 0173-0835 R&D Projects: GA ČR GA206/08/1587 Institutional research plan: CEZ:AV0Z80020508 Keywords : Haplogroup * High-throughput SNP genotyping * MALDI-TOF MS * Mitochondrial DNA * Multiplex assay Subject RIV: AC - Archeology, Anthropology, Ethnology Impact factor: 3.077, year: 2009 http://www3.interscience.wiley.com/journal/122665008/abstract?CRETRY=1&SRETRY=0

  16. Environmental implications of large-scale adoption of wind power: a scenario-based life cycle assessment

    International Nuclear Information System (INIS)

    Arvesen, Anders; Hertwich, Edgar G

    2011-01-01

    We investigate the potential environmental impacts of a large-scale adoption of wind power to meet up to 22% of the world’s growing electricity demand. The analysis builds on life cycle assessments of generic onshore and offshore wind farms, meant to represent average conditions for global deployment of wind power. We scale unit-based findings to estimate aggregated emissions of building, operating and decommissioning wind farms toward 2050, taking into account changes in the electricity mix in manufacturing. The energy scenarios investigated are the International Energy Agency’s BLUE scenarios. We estimate 1.7–2.6 Gt CO 2 -eq climate change, 2.1–3.2 Mt N-eq marine eutrophication, 9.2–14 Mt NMVOC photochemical oxidant formation, and 9.5–15 Mt SO 2 -eq terrestrial acidification impact category indicators due to global wind power in 2007–50. Assuming lifetimes 5 yr longer than reference, the total climate change indicator values are reduced by 8%. In the BLUE Map scenario, construction of new capacity contributes 64%, and repowering of existing capacity 38%, to total cumulative greenhouse gas emissions. The total emissions of wind electricity range between 4% and 14% of the direct emissions of the replaced fossil-fueled power plants. For all impact categories, the indirect emissions of displaced fossil power are larger than the total emissions caused by wind power.

  17. Structure Elucidation of Unknown Metabolites in Metabolomics by Combined NMR and MS/MS Prediction.

    Science.gov (United States)

    Boiteau, Rene M; Hoyt, David W; Nicora, Carrie D; Kinmonth-Schultz, Hannah A; Ward, Joy K; Bingol, Kerem

    2018-01-17

    We introduce a cheminformatics approach that combines highly selective and orthogonal structure elucidation parameters; accurate mass, MS/MS (MS²), and NMR into a single analysis platform to accurately identify unknown metabolites in untargeted studies. The approach starts with an unknown LC-MS feature, and then combines the experimental MS/MS and NMR information of the unknown to effectively filter out the false positive candidate structures based on their predicted MS/MS and NMR spectra. We demonstrate the approach on a model mixture, and then we identify an uncatalogued secondary metabolite in Arabidopsis thaliana . The NMR/MS² approach is well suited to the discovery of new metabolites in plant extracts, microbes, soils, dissolved organic matter, food extracts, biofuels, and biomedical samples, facilitating the identification of metabolites that are not present in experimental NMR and MS metabolomics databases.

  18. Analytical Method Details (MS): SE53_MS03 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available SE53_MS03 CE-TOF/MS Agilent CE capillary electrophoresis system,Agilent G3250AA LC/...s were performed using an Agilent CE capillary electrophoresis system (Agilent Technologies, Waldbronn, Germ

  19. Letter report: status on code maintenance (EQ3/6)

    International Nuclear Information System (INIS)

    Wolery, T.J.

    1995-01-01

    EQ3/6 is a software package for geochemical modeling of aqueous systems, such as water/rock or waste/water rock. It is being developed for a variety of applications in geochemical studies for the Yucca Mountain Site Characterization Project. Version 7.2a was the first version of this software to be certified for use in quality- affecting work (originally issued for use in non-quality-affecting work only on 12/28/93; certified on S/17/94). In the past year, the Version 7 line software has been maintained while the new Version 8 line has been developed. In this period, sixteen defect reports have been logged and resolved. Corrected software is being released as Version 7.2b. Defect reporting and resolution for the Version 7 line will continue until all released versions in this line are retired, perhaps six months to a year after Version 8.0 is released later this year. The Version 7 software is written in Fortran 77, technically speaking, but incorporates many aspects of older Fortran. The Version 8 software is written in a much more modern Fortran, technically somewhere between Fortran 77 and Fortran 90. Future code maintenance activities will include a more complete move to Fortran 90, as well as continued maintaining of defect reporting and resolution

  20. Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup.

    Science.gov (United States)

    Cheng, Keding; Sloan, Angela; McCorrister, Stuart; Peterson, Lorea; Chui, Huixia; Drebot, Mike; Nadon, Celine; Knox, J David; Wang, Gehua

    2014-12-01

    The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. Label-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. With LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Multi-Segment Direct Inject nano-ESI-LTQ-FT-ICR-MS/MS For Protein Identification

    Directory of Open Access Journals (Sweden)

    Neal Rachel E

    2011-07-01

    Full Text Available Abstract Reversed phase high performance liquid chromatography (HPLC interfaced to electrospray tandem mass spectrometry (MS/MS is commonly used for the identification of peptides from proteolytically cleaved proteins embedded in a polyacrylamide gel matrix as well as for metabolomics screening. HPLC separations are time consuming (30-60 min average, costly (columns and mobile phase reagents, and carry the risk of column carry over between samples. The use of a chip-based nano-ESI platform (Advion NanoMate based on replaceable nano-tips for sample introduction eliminates sample cross-contamination, provides unchanging sample matrix, and enhances spray stability with attendant increases in reproducibility. Recent papers have established direct infusion nano-ESI-MS/MS utilizing the NanoMate for protein identification of gel spots based on full range MS scans with data dependent MS/MS. In a full range scan, discontinuous ion suppression due to sample matrix can impair identification of putative mass features of interest in both the proteomic and metabolomic workflows. In the current study, an extension of an established direct inject nano-ESI-MS/MS method is described that utilizes the mass filtering capability of an ion-trap for ion packet separation into four narrow mass ranges (50 amu overlap with segment specific dynamic data dependent peak inclusion for MS/MS fragmentation (total acquisition time of 3 minutes. Comparison of this method with a more traditional nanoLC-MS/MS based protocol utilizing solvent/sample stream splitting to achieve nanoflow demonstrated comparable results for protein identification from polyacrylamide gel matrices. The advantages of this method include full automation, lack of cross-contamination, low cost, and high throughput.

  2. Disponibilidade biológica do fósforo de diferentes fontes para eqüinos em crescimento

    Directory of Open Access Journals (Sweden)

    FURTADO CARLOS EDUARDO

    2000-01-01

    Full Text Available Objetivou-se neste estudo, determinar a disponibilidade biológica do P de diferentes fontes, para eqüinos em fase de crescimento. Utilizaram-se dezesseis eqüinos machos em fase de crescimento, submetidos à aplicação de quatro fontes fosfatadas -- fosfato de rocha de Tapira (TAP, fosfato de rocha de Patos de Minas (PAT, fosfato bicálcico (BIC e farinha de osso (FOS --, adicionadas à dieta basal em quantidades suficientes para fornecer 22 g de P/animal/dia. No 16º dia, foram-lhes injetados 30 MBq de 32P/animal, e coletaram-se amostras de sangue, fezes e urina, durante sete dias. Foram determinadas as atividades específicas no plasma, fezes e urina e calculou-se a perda endógena fecal e a absorção real de P. Os valores obtidos quanto ao P consumido, P excretado, P no plasma e P retido não apresentaram diferenças estatísticas (P>0,05. Os valores de absorção real do P do TAP, PAT, BIC e da FOS foram, respectivamente, 25,23%, 33,97%, 31,71% e 29,36%. Não houve diferenças estatísticas (P>0,05 entre as fontes estudadas. Em relação ao BIC, as rochas fosfáticas apresentaram altos valores de disponibilidade biológica.

  3. Intoxicações em eqüinos no Brasil Intoxications in horses in Brazil

    Directory of Open Access Journals (Sweden)

    Franklin Riet-Correa

    1998-12-01

    Full Text Available Relatam-se algumas intoxicações descritas em eqüídeos no Brasil. Dentre as intoxicações por plantas, incluem-se: Senecio spp., Ateleia glazioviana, Crotalaria juncea, Equisetum spp., Pteridium aquilinum, Baccharis coridifolia, Senna occidentalis e Brachiaria spp.. Mencionam-se, também, as micotoxicoses causadas por Fusarium moniliforme, Claviceps purpurea e aflatoxinas, e as intoxicações por uréia, iodo, chumbo e inseticidas clorados.Toxic disease reported in horses in Brazil are reviewed. Intoxications by plants including: Senecio spp, Ateleia glazioviana, Crotalaria juncea, Equisetum spp., Pteridium aquilinum, Baccharis coridifolia, Senna occidentalis e Brachiaria spp. are described. Mycotoxicosis caused by Fusarium moniliforme, Claviceps purpurea and aflatoxins, and intoxications by urea, iodine, lead, chlorinated insecticides are also mentioned.

  4. The Relationship between EQ & Constructive and Non-Constructive Problem Solving Styles among Payame Noor University's Students of Abadan in the Year 2014

    Science.gov (United States)

    Rajaeipoor, Saeed; Siadat, Ali; Hoveida, Reza; Mohammadi, Nazanin; Keshavarz, Akbar; Salimi, Mohammad Hossein; Abbasian, Mohammad Reza; Shamsi, Ali

    2015-01-01

    The objective of the present study is considering the relationship between EQ & constructive and non-constructive problem solving styles among students. The applied methodology is cross-correlation method. The statistical population in this study is all the educational sciences' students of Payame Noor university of Abadan in the year 2014 and…

  5. Plan for integrated testing for NNWSI [Nevada Nuclear Waste Storage Investigations] non EQ3/6 data base portion

    International Nuclear Information System (INIS)

    Oversby, V.M.

    1987-01-01

    The purposes of the Integrated Testing Task are to develop laboratory data on thermodynamic properties for actinide and fission product elements for use in the EQ3/6 geochemical modelling code; to determine the transport properties of radionuclides in the near-field environment; and develop and validate a model to describe the rate of release of radionuclides from the near-field environment. Activities to achieve the firs item have been described in the Scientific Investigation Plan for EQ3/6, where quality assurance levels were assigned to the acitivities. This Scientific Investigation Plan describes activities to achieve the second and third purposes. The information gathered in these activities will be used to assess compliance with the performance objective for the Engineered Barrier System (EBS) to control the rate of release of radionuclides if the repository license application includes part of the host rock; to provide a source term for release of radionuclides from the waste package near-field environment to the system performance assessment task for use in showing compliance with the Environmental Protection Agency requirements; and to provide a source term for release of radionculides from the waste package near-field environment to the system performance assessment task for use in doing calculations of cumulative releases of radionuclides from the repository over 100,000 years as required by the site evaluation process. 5 refs

  6. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... times as often as men; in PPMS, the number of women and men are approximately equal. RRMS ...

  7. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Living Well with MS Diet, Exercise & Healthy Behaviors Emotional Well-Being Spiritual Well-Being Cognitive Health Work, ... MS Anesthesia and Surgery Managing Your MS d Emotional Well-Being Mood Changes d Spiritual Well-Being ...

  8. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... of Distinction Lawry Circle Circle of Influence d Planned Giving d Other Ways to Give Donate by ...

  9. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Trials in MS Wellness and Lifestyle Research Diet Vitamin D How and Why Do Scientists Share Results ... The National MS Society is Here to Help Need More Information? We Are Here Our MS Navigators ...

  10. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... Community at MSconnection.org Join a Local Support Group Peer Connections: One-on-One Edward M. Dowd ...

  11. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... Review of Society's Research Programs d Careers d Leadership Board of Directors Senior Leadership Team Founder Sylvia ...

  12. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... working effectively. How does RRMS differ from progressive types of MS? While RRMS is defined by attacks ... Pinterest MS Connection About the Society Vision Careers Leadership Cultural Values Financials News Press Room MS Prevalence ...

  13. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Room Events at a Glance MS the Disease Public Service Announcements In the News Archives d MS ... For Professionals Researchers Physicians Nurses Rehabilitation Professionals Mental Health Professionals Health and Wellness Professionals What Is MS? ...

  14. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS African Americans Hispanics & Latino/as d Multiple ... Questions to Ask d Resources for Specific Populations Pediatric MS Support Veterans with Multiple Sclerosis d Find ...

  15. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Conditions to Rule Out For Clinicians Treating MS Comprehensive Care Find an MS Care Provider Medications Managing ... ADEM) d For Clinicians d Treating MS d Comprehensive Care Developing a Healthcare Team Make the Most ...

  16. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    Science.gov (United States)

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  17. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Viruses Clusters d Who Gets MS? Pediatric MS African Americans Hispanics & Latino/as d Multiple Sclerosis FAQs d ... Diet & Nutrition Exercise Heat & Temperature Sensitivity Sleep Vaccinations Women's Health Unhealthy Habits Managing MS and Another Condition ...

  18. MS-SQL data base programming

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Chang Bae; Kim, Nam Jung; Lee, Hyeong Gyo

    2002-07-15

    This is about MS-SQL data base programming which is divided into thirteen chapters. The contents of this book are to understand MS-SQL 2000 DBMS with its composition, new function and history of MS-SQL, to learn conception of data base, install, run and closing of MS-SQL 2000 DBMS, to deal with the basic of MS-SQL DBMS, to handle the intermediate level of MS-SQL DBMS, to deal with MS-SQL DBMS in advanced level, to practice query like changing data base and checking of data lists, function on its use and data diff, get date, date add, char, upper and system function, set-up of MS-SQL ODBC, constructing of web server of windows 2000, web programming using visual studio.net.making board and making reference room.

  19. MS-SQL data base programming

    International Nuclear Information System (INIS)

    Noh, Chang Bae; Kim, Nam Jung; Lee, Hyeong Gyo

    2002-07-01

    This is about MS-SQL data base programming which is divided into thirteen chapters. The contents of this book are to understand MS-SQL 2000 DBMS with its composition, new function and history of MS-SQL, to learn conception of data base, install, run and closing of MS-SQL 2000 DBMS, to deal with the basic of MS-SQL DBMS, to handle the intermediate level of MS-SQL DBMS, to deal with MS-SQL DBMS in advanced level, to practice query like changing data base and checking of data lists, function on its use and data diff, get date, date add, char, upper and system function, set-up of MS-SQL ODBC, constructing of web server of windows 2000, web programming using visual studio.net.making board and making reference room.

  20. Analytical Method Details (MS): SE2_MS3 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available 00.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1)., Rejected mass=284.2000;300.2000;328.2000;344.2000;372.2000;388.2000;416.3000;432.3000;460.0000. ...

  1. Exploration of the association between quality of life, assessed by the EQ-5D and ICECAP-O, and falls risk, cognitive function and daily function, in older adults with mobility impairments

    Directory of Open Access Journals (Sweden)

    Davis Jennifer C

    2012-10-01

    Full Text Available Abstract Background Our research sought to understand how falls risk, cognitive function, and daily function are associated with health related quality of life (using the EuroQol-5D and quality of life (using the ICECAP-O among older adults with mobility impairments. Methods The EQ-5D and ICECAP-O were administered at 12 months post first clinic attendance at the Vancouver Falls Prevention Clinic. We report descriptive statistics for all baseline characteristics collected at first clinic visit and primary outcomes of interest. Using multivariate stepwise linear regression, we assessed the construct validity of the EQ-5D and ICECAP-O using three dependent measures that are recognized indicators of “impaired mobility” – physiological falls risk, general balance and mobility, and cognitive status among older adults. Results We report data on 215 seniors who attended the Vancouver Falls Prevention Clinic and received their first clinic assessment. Patients had a mean age of 79.3 (6.2 years. After accounting for known covariates (i.e., age and sex, the ICECAP-O domains explained a greater amount of variation in each of the three dependent measures compared with the EQ-5D domains. Conclusion Both the EQ-5D and ICECAP-O demonstrate associations with falls risk and general balance and mobility; however, only the ICECAP-O was associated with cognitive status among older adults with mobility impairments. Trial registration ClinicalTrials.gov Identifier: NCT01022866

  2. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Treating MS d Comprehensive Care Developing a Healthcare Team Make the Most of Your Doctor Visits Advance Medical Directives d Find an MS Care Provider Partners in MS Care d Managing Relapses Plasmapheresis d Rehabilitation Functional Electrical Stimulation (FES) ...

  3. Simple and rapid quantification of vancomycin in serum, urine and peritoneal/pleural effusion via UHPLC-MS/MS applicable to personalized antibiotic dosing research.

    Science.gov (United States)

    Javorska, Lenka; Krcmova, Lenka Kujovska; Solich, Petr; Kaska, Milan

    2017-08-05

    Management of the therapy of life-threatening bacterial infection is extremely based on an optimal antibiotic treatment. Achieving the correct vancomycin dosage in blood and target tissues can be complicated in special situations, e.g., where large fluid sequestration and/or acute renal failure occur. A UHPLC-MS/MS method operating in electrospray (ESI) positive ion mode was applied for the determination of vancomycin in serum, urine and peritoneal/pleural effusion. Sample pretreatment was composed of dilution and simple protein precipitation where only a small volume (50μL) of serum, urine or peritoneal/pleural effusion was required. The separation of vancomycin was performed on a Meteoric Core C18 BIO column (100×4.6mm, 2.7μm) by gradient elution with 0.1% formic acid in water and acetonitrile. The total time of analysis was 4.5min. The method was found to be linear in the range of 2-60μM (or 0.5-10μM) for serum, 0.27-10μM (or 2-60μM) for peritoneal/pleural effusion and 25-300μM for urine, which was adequate for the determination of vancomycin in patient samples. The intra- and inter-day precision was below 8% RSD, and accuracy was from 89 to 104%. The UHPLC/MS-MS method offers a fast and reliable approach to determine vancomycin concentrations in three different human body fluid samples (serum, urine and peritoneal/pleural effusion) with a simple sample pretreatment that was the same for all selected specimens. This method should be applicable to large sample series in clinical (pharmacokinetic/pharmacodynamic) studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Quantification of amlodipine and atorvastatin in human plasma by UPLC-MS/MS method and its application to a bioequivalence study.

    Science.gov (United States)

    Rezk, Mamdouh R; Badr, Kamal A

    2018-07-01

    A robust, rapid and sensitive UPLC-MS/MS method has been developed, optimized and validated for the determination of amlodipine (AML) and atorvastatin (ATO) in human plasma using eplerenone as an internal standard (IS). Multiple-reaction monitoring in positive electrospray ionization mode was utilized in Xevo TQD LC-MS/MS. Double extraction was used in sample preparation using diethyl ether and ethyl acetate. The prepared samples were analyzed using an Acquity UPLC BEH C 18 (50 × 2.1 mm, 1.7 μm) column. Ammonium formate and acetonitrile, pumped isocraticaly at a flow rate of 0.25 mL/min, were used as a mobile phase. Method validation was done as per the US Food and Drug Administration guidelines. Linearity was achieved in the range of 0.1-10 ng/mL for AML and 0.05-50 ng/mL for ATO. Intra-day and inter-day accuracy and precision were calculated and found to be within the acceptable range. A short run time, of <1.5 min, permits analysis of a large number of plasma samples per batch. The developed and validated method was applied to estimate AML and ATO in a bioequivalence study in healthy human volunteers. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Post-traumatic stress syndrome in a large sample of older adults: determinants and quality of life.

    Science.gov (United States)

    Lamoureux-Lamarche, Catherine; Vasiliadis, Helen-Maria; Préville, Michel; Berbiche, Djamal

    2016-01-01

    The aims of this study are to assess in a sample of older adults consulting in primary care practices the determinants and quality of life associated with post-traumatic stress syndrome (PTSS). Data used came from a large sample of 1765 community-dwelling older adults who were waiting to receive health services in primary care clinics in the province of Quebec. PTSS was measured with the PTSS scale. Socio-demographic and clinical characteristics were used as potential determinants of PTSS. Quality of life was measured with the EuroQol-5D-3L (EQ-5D-3L) EQ-Visual Analog Scale and the Satisfaction With Your Life Scale. Multivariate logistic and linear regression models were used to study the presence of PTSS and different measures of health-related quality of life and quality of life as a function of study variables. The six-month prevalence of PTSS was 11.0%. PTSS was associated with age, marital status, number of chronic disorders and the presence of an anxiety disorder. PTSS was also associated with the EQ-5D-3L and the Satisfaction with Your Life Scale. PTSS is prevalent in patients consulting in primary care practices. Primary care physicians should be aware that PTSS is also associated with a decrease in quality of life, which can further negatively impact health status.

  6. The large-s field-reversed configuration experiment

    International Nuclear Information System (INIS)

    Hoffman, A.L.; Carey, L.N.; Crawford, E.A.; Harding, D.G.; DeHart, T.E.; McDonald, K.F.; McNeil, J.L.; Milroy, R.D.; Slough, J.T.; Maqueda, R.; Wurden, G.A.

    1993-01-01

    The Large-s Experiment (LSX) was built to study the formation and equilibrium properties of field-reversed configurations (FRCs) as the scale size increases. The dynamic, field-reversed theta-pinch method of FRC creation produces axial and azimuthal deformations and makes formation difficult, especially in large devices with large s (number of internal gyroradii) where it is difficult to achieve initial plasma uniformity. However, with the proper technique, these formation distortions can be minimized and are then observed to decay with time. This suggests that the basic stability and robustness of FRCs formed, and in some cases translated, in smaller devices may also characterize larger FRCs. Elaborate formation controls were included on LSX to provide the initial uniformity and symmetry necessary to minimize formation disturbances, and stable FRCs could be formed up to the design goal of s = 8. For x ≤ 4, the formation distortions decayed away completely, resulting in symmetric equilibrium FRCs with record confinement times up to 0.5 ms, agreeing with previous empirical scaling laws (τ∝sR). Above s = 4, reasonably long-lived (up to 0.3 ms) configurations could still be formed, but the initial formation distortions were so large that they never completely decayed away, and the equilibrium confinement was degraded from the empirical expectations. The LSX was only operational for 1 yr, and it is not known whether s = 4 represents a fundamental limit for good confinement in simple (no ion beam stabilization) FRCs or whether it simply reflects a limit of present formation technology. Ideally, s could be increased through flux buildup from neutral beams. Since the addition of kinetic or beam ions will probably be desirable for heating, sustainment, and further stabilization of magnetohydrodynamic modes at reactor-level s values, neutral beam injection is the next logical step in FRC development. 24 refs., 21 figs., 2 tabs

  7. LC-MS-MS identification of drug metabolites obtained by metalloporphyrin mediated oxidation

    Directory of Open Access Journals (Sweden)

    Maurin Andrea J. M.

    2003-01-01

    Full Text Available In this paper we report the application of liquid chromatography-mass spectrometry (LC-MS-MS to the identification of the products formed by oxidation of albendazole and disopyramide with metalloporphyrins in dichloroethane, using iodosylbenzene as an oxygen donor. Our results show that LC-MS-MS is a powerful tool to study the in vitro metabolism of drugs, allowing the identification of known and unknown metabolites. In addition, it was observed that the catalyst system used resulted in the formation of the same metabolites as obtained in vivo, although for disopyramide other products were also observed.

  8. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.

    Science.gov (United States)

    Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana

    2016-09-01

    DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.

  9. A large-scale study of anxiety and depression in people with Multiple Sclerosis: a survey via the web portal of the UK MS Register.

    Directory of Open Access Journals (Sweden)

    Kerina H Jones

    Full Text Available Studies have found that people with Multiple Sclerosis experience relatively high rates of anxiety and depression. Although methodologically robust, many of these studies had access to only modest sample sizes (N4000 to: describe the depression and anxiety profiles of people with MS; to determine if anxiety and depression are related to age or disease duration; and to assess whether the levels of anxiety and depression differ between genders and types of MS.From its launch in May 2011 to the end of December 2011, 7786 adults with MS enrolled to take part in the UK MS Register via the web portal. The responses to the Hospital Anxiety and Depression Scale (HADS were collated with basic demographic and descriptive MS data provided at registration and the resulting dataset was analysed in SPSS (v.16.The mean HADS score among the 4178 respondents was 15.7 (SE 0.117, SD 7.55 with a median of 15.0 (IQR 11. Anxiety and depression rates were notably high, with over half (54.1% scoring ≥ 8 for anxiety and 46.9% scoring ≥ 8 for depression. Women with relapsing-remitting MS were more anxious than men with this type (p<0.001, and than women with other types of MS (p = 0.017. Within each gender, men and women with secondary progressive MS were more depressed than men or women with other types of MS (p<0.001, p<0.001.This largest known study of its kind has shown that anxiety and depression are highly prevalent in people with MS, indicating that their mental health needs could be better addressed. These findings support service planning and further research to provide the best care for people with MS to help alleviate these debilitating conditions.

  10. Effect-based trigger values for in vitro and in vivo bioassays performed on surface water extracts supporting the environmental quality standards (EQS) of the European Water Framework Directive.

    Science.gov (United States)

    Escher, Beate I; Aїt-Aїssa, Selim; Behnisch, Peter A; Brack, Werner; Brion, François; Brouwer, Abraham; Buchinger, Sebastian; Crawford, Sarah E; Du Pasquier, David; Hamers, Timo; Hettwer, Karina; Hilscherová, Klára; Hollert, Henner; Kase, Robert; Kienle, Cornelia; Tindall, Andrew J; Tuerk, Jochen; van der Oost, Ron; Vermeirssen, Etienne; Neale, Peta A

    2018-07-01

    Effect-based methods including cell-based bioassays, reporter gene assays and whole-organism assays have been applied for decades in water quality monitoring and testing of enriched solid-phase extracts. There is no common EU-wide agreement on what level of bioassay response in water extracts is acceptable. At present, bioassay results are only benchmarked against each other but not against a consented measure of chemical water quality. The EU environmental quality standards (EQS) differentiate between acceptable and unacceptable surface water concentrations for individual chemicals but cannot capture the thousands of chemicals in water and their biological action as mixtures. We developed a method that reads across from existing EQS and includes additional mixture considerations with the goal that the derived effect-based trigger values (EBT) indicate acceptable risk for complex mixtures as they occur in surface water. Advantages and limitations of various approaches to read across from EQS are discussed and distilled to an algorithm that translates EQS into their corresponding bioanalytical equivalent concentrations (BEQ). The proposed EBT derivation method was applied to 48 in vitro bioassays with 32 of them having sufficient information to yield preliminary EBTs. To assess the practicability and robustness of the proposed approach, we compared the tentative EBTs with observed environmental effects. The proposed method only gives guidance on how to derive EBTs but does not propose final EBTs for implementation. The EBTs for some bioassays such as those for estrogenicity are already mature and could be implemented into regulation in the near future, while for others it will still take a few iterations until we can be confident of the power of the proposed EBTs to differentiate good from poor water quality with respect to chemical contamination. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Phylogenetic Analysis of the MS4A and TMEM176 Gene Families

    Science.gov (United States)

    Zuccolo, Jonathan; Bau, Jeremy; Childs, Sarah J.; Goss, Greg G.; Sensen, Christoph W.; Deans, Julie P.

    2010-01-01

    Background The MS4A gene family in humans includes CD20 (MS4A1), FcRβ (MS4A2), Htm4 (MS4A3), and at least 13 other syntenic genes encoding membrane proteins, most having characteristic tetraspanning topology. Expression of MS4A genes is variable in tissues throughout the body; however, several are limited to cells in the hematopoietic system where they have known roles in immune cell functions. Genes in the small TMEM176 group share significant sequence similarity with MS4A genes and there is evidence of immune function of at least one of the encoded proteins. In this study, we examined the evolutionary history of the MS4A/TMEM176 families as well as tissue expression of the phylogenetically earliest members, in order to investigate their possible origins in immune cells. Principal Findings Orthologs of human MS4A genes were found only in mammals; however, MS4A gene homologs were found in most jawed vertebrates. TMEM176 genes were found only in mammals and bony fish. Several unusual MS4A genes having 2 or more tandem MS4A sequences were identified in the chicken (Gallus gallus) and early mammals (opossum, Monodelphis domestica and platypus, Ornithorhyncus anatinus). A large number of highly conserved MS4A and TMEM176 genes was found in zebrafish (Danio rerio). The most primitive organism identified to have MS4A genes was spiny dogfish (Squalus acanthus). Tissue expression of MS4A genes in S. acanthias and D. rerio showed no evidence of expression restricted to the hematopoietic system. Conclusions/Significance Our findings suggest that MS4A genes first appeared in cartilaginous fish with expression outside of the immune system, and have since diversified in many species into their modern forms with expression and function in both immune and nonimmune cells. PMID:20186339

  12. MsLDR-creator: a web service to design msLDR assays.

    Science.gov (United States)

    Bormann, Felix; Dahl, Andreas; Sers, Christine

    2012-03-01

    MsLDR-creator is a free web service to design assays for the new DNA methylation detection method msLDR. The service provides the user with all necessary information about the oligonucleotides required for the measurement of a given CpG within a sequence of interest. The parameters are calculated by the nearest neighbour approach to achieve optimal behaviour during the experimental procedure. In addition, to guarantee a good start using msLDR, further information, like protocols and hints and tricks, are provided.

  13. Analytical Method Details (MS): SE29_MS1 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available SE29_MS1 LC-FT-ICR-MS ESI positive method 1 Agilent1100 HPLC (Agilent), LTQ-FT (The... (100mg) are solved in 300uL 80% methanol solution. 20uL sample is injected into HPLC after 0.2um membrane filter treatment. HPLC

  14. Quantification of the level descriptors for the standard EQ-5D three-level system and a five-level version according to two methods

    NARCIS (Netherlands)

    M.F. Janssen (Bas); E. Birnie (Erwin); G.J. Bonsel (Gouke)

    2008-01-01

    textabstractObjectives: Our aim was to compare the quantitative position of the level descriptors of the standard EQ-5D three-level system (3L) and a newly developed, experimental five-level version (5L) using a direct and a vignette-based indirect method. Methods: Eighty-two respondents took part

  15. Combined use of ESI-QqTOF-MS and ESI-QqTOF-MS/MS with mass-spectral library search for qualitative analysis of drugs.

    Science.gov (United States)

    Pavlic, Marion; Libiseller, Kathrin; Oberacher, Herbert

    2006-09-01

    The potential of the combined use of ESI-QqTOF-MS and ESI-QqTOF-MS/MS with mass-spectral library search for the identification of therapeutic and illicit drugs has been evaluated. Reserpine was used for standardizing experimental conditions and for characterization of the performance of the applied mass spectrometric system. Experiments revealed that because of the mass accuracy, the stability of calibration, and the reproducibility of fragmentation, the QqTOF mass spectrometer is an appropriate platform for establishment of a tandem-mass-spectral library. Three-hundred and nineteen substances were used as reference samples to build the spectral library. For each reference compound, product-ion spectra were acquired at ten different collision-energy values between 5 eV and 50 eV. For identification of unknown compounds, a library search algorithm was developed. The closeness of matching between a measured product-ion spectrum and a spectrum stored in the library was characterized by a value called "match probability", which took into account the number of matched fragment ions, the number of fragment ions observed in the two spectra, and the sum of the intensity differences calculated for matching fragments. A large value for the match probability indicated a close match between the measured and the reference spectrum. A unique feature of the library search algorithm-an implemented spectral purification option-enables characterization of multi-contributor fragment-ion spectra. With the aid of this software feature, substances comprising only 1.0% of the total amount of binary mixtures were unequivocally assigned, in addition to the isobaric main contributors. The spectral library was successfully applied to the characterization of 39 forensic casework samples.

  16. A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks.

    Science.gov (United States)

    Drury, Nicholas; Ramotowski, Robert; Moini, Mehdi

    2018-05-23

    Ambient ionization mass spectrometry is gaining momentum in forensic science laboratories because of its high speed of analysis, minimal sample preparation, and information-rich results. One such application of ambient ionization methodology includes the analysis of writing inks from questioned documents where colorants of interest may not be soluble in common solvents, rendering thin layer chromatography (TLC) and separation-mass spectrometry methods such as LC/MS (-MS) impractical. Ambient ionization mass spectrometry uses a variety of ionization techniques such as penning ionization in Direct Analysis in Real Time (DART), and atmospheric pressure chemical ionization in Direct Sample Analysis (DSA), and electrospray ionization in Desorption Electrospray Ionization (DESI). In this manuscript, two of the commonly used ambient ionization techniques are compared: Perkin Elmer DSA-MS and IonSense DART in conjunction with a JEOL AccuTOF MS. Both technologies were equally successful in analyzing writing inks and produced similar spectra. DSA-MS produced less background signal likely because of its closed source configuration; however, the open source configuration of DART-MS provided more flexibility for sample positioning for optimum sensitivity and thereby allowing smaller piece of paper containing writing ink to be analyzed. Under these conditions, the minimum sample required for DART-MS was 1mm strokes of ink on paper, whereas DSA-MS required a minimum of 3mm. Moreover, both techniques showed comparable repeatability. Evaluation of the analytical figures of merit, including sensitivity, linear dynamic range, and repeatability, for DSA-MS and DART-MS analysis is provided. To the forensic context of the technique, DART-MS was applied to the analysis of United States Secret Service ink samples directly on a sampling mesh, and the results were compared with DSA-MS of the same inks on paper. Unlike analysis using separation mass spectrometry, which requires sample

  17. Natural isotope correction of MS/MS measurements for metabolomics and (13)C fluxomics.

    Science.gov (United States)

    Niedenführ, Sebastian; ten Pierick, Angela; van Dam, Patricia T N; Suarez-Mendez, Camilo A; Nöh, Katharina; Wahl, S Aljoscha

    2016-05-01

    Fluxomics and metabolomics are crucial tools for metabolic engineering and biomedical analysis to determine the in vivo cellular state. Especially, the application of (13)C isotopes allows comprehensive insights into the functional operation of cellular metabolism. Compared to single MS, tandem mass spectrometry (MS/MS) provides more detailed and accurate measurements of the metabolite enrichment patterns (tandem mass isotopomers), increasing the accuracy of metabolite concentration measurements and metabolic flux estimation. MS-type data from isotope labeling experiments is biased by naturally occurring stable isotopes (C, H, N, O, etc.). In particular, GC-MS(/MS) requires derivatization for the usually non-volatile intracellular metabolites introducing additional natural isotopes leading to measurements that do not directly represent the carbon labeling distribution. To make full use of LC- and GC-MS/MS mass isotopomer measurements, the influence of natural isotopes has to be eliminated (corrected). Our correction approach is analyzed for the two most common applications; (13)C fluxomics and isotope dilution mass spectrometry (IDMS) based metabolomics. Natural isotopes can have an impact on the calculated flux distribution which strongly depends on the substrate labeling and the actual flux distribution. Second, we show that in IDMS based metabolomics natural isotopes lead to underestimated concentrations that can and should be corrected with a nonlinear calibration. Our simulations indicate that the correction for natural abundance in isotope based fluxomics and quantitative metabolomics is essential for correct data interpretation. © 2015 Wiley Periodicals, Inc.

  18. ANALISIS PENGARUH EMOTIONAL QUOTIENT (EQ DAN STRES KERJA TERHADAP PERFORMA KERJA KARYAWAN PADA PT. BANK MESTIKA DHARMA MEDAN

    Directory of Open Access Journals (Sweden)

    Bambang Bambang

    2013-02-01

    Full Text Available Human Resources are a generator of available resources in the activities and routine of an organization or company that the good and the bad performance of an organization are determined by the performance of human resources. Professional employee  is a reliable employee with balanced quality between academic and emotional capability. Academic intelligence is frequently given a higher position than emotional intelligence is an individual evaluation. Emotional intelligence is the factor  determining the effectiveness of someone is working that with high emotional intelligence, the human resources can be easily directed and guided to work in accordance with the goals of organization. The prupose of this quantitative descriptive explanatory study was to look at the influence of Emotional Quotient (EQ and Work Stress on the performance of the employees of PT. Bank Mestika Dharma Medan using the theory of human resources management related to Emotional Quotient (EQ, work stress and work performance. The population of this study was 585 employees and 238 of them were selected to be the samples for this study. The data obtained were analyzed through multiple linear regression tests using F test to simultaneously test the hypothesis and using t test to do a partial test. The result of the hypothesis test showed that simultaneously the variable of Emotional Quotient and work stress had a significant influence on the improvemnet of the performance  of the employees of PT. Bank Mestika Dharma Medan

  19. Testes genéticos na eqüideocultura

    Directory of Open Access Journals (Sweden)

    Eduardo Geraldo Alves Coelho

    2008-07-01

    Full Text Available Nos últimos anos a equideocultura deu um salto qualitativo, havendo hoje, no mercado, animais de alto valor e geneticamente superiores. Isso é possível, em grande parte, devido aos avanços na área da genética animal, os quais permitem identificar, não apenas anomalias, mas também diversos genes de interesse econômico. Com o auxílio da citogenética pode-se identificar indivíduos com alterações no número ou na estrutura dos cromossomos, o que em muitos casos afeta principalmente a reprodução. Também a confirmação de genealogia, anteriormente feita por tipagem sangüínea e atualmente por testes de DNA, tem papel extremamente importante, não apenas por garantir a ascendência dos animais, mas também porque um pedigree confiável pode permitir ao criador identificar a origem de problemas genéticos em seu rebanho e reduzi-los ou mesmo, eliminá-los. Ainda com as ferramentas da biologia molecular, podemos hoje, identificar indivíduos que apresentam genes desejáveis ou indesejáveis, o que nos permite selecioná-los precocemente, reduzindo assim, os custos do produtor e aumentando o valor agregado dos animais. Entre tais genes podemos destacar os que identificam portadores ou afetados por mutações genéticas indesejáveis como: SCID (Síndrome da Imunodeficiência Combinada, HYPP (Parilisa Hipercalêmica, HERDA (Astenia Dérmica Regional Hereditária Eqüina, etc. Também a identificação dos genes que determinam a cor ou padrão da pelagem já pode ser feita direta ou indiretamente (por meio de marcadores genéticos, como é o caso dos genes para as pelagens Overo, Tobiano, etc. Com os avanços no estudo do genoma eqüino muito mais estará disponível em breve, o que certamente só trará maiores contribuições à equideocultura mundial.In the last few years the horse breeding industry is achieving significant progresses producing animals of high commercial value and genetically superior. It was possible, mainly due to

  20. Modelling uranium solubilities in aqueous solutions: Validation of a thermodynamic data base for the EQ3/6 geochemical codes

    International Nuclear Information System (INIS)

    Puigdomenech, I.; Bruno, J.

    1988-01-01

    Experimental solubilities of U 4+ and UO 2 2+ that are reported in the literature have been collected. Data on oxides, hydroxides and carbonates have been selected for this work. They include results both at 25 degrees C and at higher temperatures. The literature data have been compared with calculated uranium solubilities obtained with the EQ3/6 geochemical modelling programs and an uranium thermodynamic data base selected for the Swedish nuclear waste management program. This verification/validiation exercise has shown that more experimental data is needed to determine the chemical composition of anionic uranyl hydroxo complexes as well as their equilibrium constants of formation. There is also a need for more solubility data on well characterised alkaline or alkaline-earth uranates. For the uranyl carbonate system, the calculated results agree reasonably well with the experimental literature values, which span over a wide range of pH, (CO 3 2- ) T , CO 2 (g)-pressure, and T. The experimental solubility of UO 2 (s) agrees also well with the EQ3/6 calculations for pH greater than 6. However, in more acidic solutions the experimental solubilities are higher than the calculated values. This is due to the formation of polynuclear hydroxo complexes of uranium, which are not well characterised, and are not included in the thermodynamic data base used in this study. (authors)

  1. Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

    Directory of Open Access Journals (Sweden)

    Raphael Hösli

    2018-01-01

    Full Text Available Phenytoin (PHT is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis, and resulted in a better LOD ( 0.995 for all tested matrices (blood, saliva, and dialysate. For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.

  2. Structure Annotation and Quantification of Wheat Seed Oxidized Lipids by High-Resolution LC-MS/MS.

    Science.gov (United States)

    Riewe, David; Wiebach, Janine; Altmann, Thomas

    2017-10-01

    Lipid oxidation is a process ubiquitous in life, but the direct and comprehensive analysis of oxidized lipids has been limited by available analytical methods. We applied high-resolution liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (MS/MS) to quantify oxidized lipids (glycerides, fatty acids, phospholipids, lysophospholipids, and galactolipids) and implemented a platform-independent high-throughput-amenable analysis pipeline for the high-confidence annotation and acyl composition analysis of oxidized lipids. Lipid contents of 90 different naturally aged wheat ( Triticum aestivum ) seed stocks were quantified in an untargeted high-resolution LC-MS experiment, resulting in 18,556 quantitative mass-to-charge ratio features. In a posthoc liquid chromatography-tandem mass spectrometry experiment, high-resolution MS/MS spectra (5 mD accuracy) were recorded for 8,957 out of 12,080 putatively monoisotopic features of the LC-MS data set. A total of 353 nonoxidized and 559 oxidized lipids with up to four additional oxygen atoms were annotated based on the accurate mass recordings (1.5 ppm tolerance) of the LC-MS data set and filtering procedures. MS/MS spectra available for 828 of these annotations were analyzed by translating experimentally known fragmentation rules of lipids into the fragmentation of oxidized lipids. This led to the identification of 259 nonoxidized and 365 oxidized lipids by both accurate mass and MS/MS spectra and to the determination of acyl compositions for 221 nonoxidized and 295 oxidized lipids. Analysis of 15-year aged wheat seeds revealed increased lipid oxidation and hydrolysis in seeds stored in ambient versus cold conditions. © 2017 The author(s). All Rights Reserved.

  3. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... and problems with cognition (learning and memory or information processing). People with progressive forms of MS are more likely to experience gradually worsening problems with walking and mobility, along with whatever other symptoms they may have. Diagnosing ... MS Society is Here to Help Need More Information? We Are Here Our MS Navigators help identify ...

  4. Quantification of the level descriptors for the standard EQ-5D three-level system and a five-level version according to two methods

    NARCIS (Netherlands)

    Janssen, M. F.; Birnie, E.; Bonsel, G. J.

    2008-01-01

    OBJECTIVES: Our aim was to compare the quantitative position of the level descriptors of the standard EQ-5D three-level system (3L) and a newly developed, experimental five-level version (5L) using a direct and a vignette-based indirect method. METHODS: Eighty-two respondents took part in the study.

  5. A new LC-ESI-MS/MS method to measure long-chain acylcarnitine levels in cultured cells

    International Nuclear Information System (INIS)

    Jauregui, Olga; Sierra, Adriana Y.; Carrasco, Patricia; Gratacos, Esther; Hegardt, Fausto G.; Casals, Nuria

    2007-01-01

    The quantitative evaluation of long-chain acylcarnitines in lipid extracts from cultured cells or tissues is a prerequisite to study carnitine palmitoyltransferase (CPT) activity. There is thus a need for the accurate measurement of the concentration of long-chain acylcarnitines at the lowest concentration present in lipid extracts. Here we report a fast and reliable quantitative method based on the use of weak acid extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to quantify acylcarnitines through hydrophilic interaction chromatography. The method was validated using isotopic dilution and the results allow the analysis of a large number of samples at low concentration levels (down to 0.35 nmol L -1 for palmitoylcarnitine) with good inter- and intra-day precision. The method was used for the quantitative study of changes in concentration of palmitoylcarnitine and other acylcarnitines in PC-12 cells over-expressing CPT1a gene. It was also used to measure CPT1 activity in mitochondria isolated from transfected cells, giving similar results to the more common radiometric method, but with higher sensitivity

  6. A new LC-ESI-MS/MS method to measure long-chain acylcarnitine levels in cultured cells

    Energy Technology Data Exchange (ETDEWEB)

    Jauregui, Olga [Scientific and Technical Services, University of Barcelona (Spain); Sierra, Adriana Y.; Carrasco, Patricia; Gratacos, Esther [Molecular and Cellular Unit, School of Health Sciences, International University of Catalonia (Spain); Hegardt, Fausto G. [Department of Biochemistry and Molecular Biology, University of Barcelona, School of Pharmacy (Spain); Casals, Nuria [Molecular and Cellular Unit, School of Health Sciences, International University of Catalonia (Spain)], E-mail: ncasals@csc.uic.es

    2007-09-05

    The quantitative evaluation of long-chain acylcarnitines in lipid extracts from cultured cells or tissues is a prerequisite to study carnitine palmitoyltransferase (CPT) activity. There is thus a need for the accurate measurement of the concentration of long-chain acylcarnitines at the lowest concentration present in lipid extracts. Here we report a fast and reliable quantitative method based on the use of weak acid extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to quantify acylcarnitines through hydrophilic interaction chromatography. The method was validated using isotopic dilution and the results allow the analysis of a large number of samples at low concentration levels (down to 0.35 nmol L{sup -1} for palmitoylcarnitine) with good inter- and intra-day precision. The method was used for the quantitative study of changes in concentration of palmitoylcarnitine and other acylcarnitines in PC-12 cells over-expressing CPT1a gene. It was also used to measure CPT1 activity in mitochondria isolated from transfected cells, giving similar results to the more common radiometric method, but with higher sensitivity.

  7. Application of survival analysis methodology to the quantitative analysis of LC-MS proteomics data.

    Science.gov (United States)

    Tekwe, Carmen D; Carroll, Raymond J; Dabney, Alan R

    2012-08-01

    Protein abundance in quantitative proteomics is often based on observed spectral features derived from liquid chromatography mass spectrometry (LC-MS) or LC-MS/MS experiments. Peak intensities are largely non-normal in distribution. Furthermore, LC-MS-based proteomics data frequently have large proportions of missing peak intensities due to censoring mechanisms on low-abundance spectral features. Recognizing that the observed peak intensities detected with the LC-MS method are all positive, skewed and often left-censored, we propose using survival methodology to carry out differential expression analysis of proteins. Various standard statistical techniques including non-parametric tests such as the Kolmogorov-Smirnov and Wilcoxon-Mann-Whitney rank sum tests, and the parametric survival model and accelerated failure time-model with log-normal, log-logistic and Weibull distributions were used to detect any differentially expressed proteins. The statistical operating characteristics of each method are explored using both real and simulated datasets. Survival methods generally have greater statistical power than standard differential expression methods when the proportion of missing protein level data is 5% or more. In particular, the AFT models we consider consistently achieve greater statistical power than standard testing procedures, with the discrepancy widening with increasing missingness in the proportions. The testing procedures discussed in this article can all be performed using readily available software such as R. The R codes are provided as supplemental materials. ctekwe@stat.tamu.edu.

  8. A Patient-Assessed Morbidity to Evaluate Outcome in Surgically Treated Vestibular Schwannomas.

    Science.gov (United States)

    Al-Shudifat, Abdul Rahman; Kahlon, Babar; Höglund, Peter; Lindberg, Sven; Magnusson, Måns; Siesjo, Peter

    2016-10-01

    Outcome after treatment of vestibular schwannomas can be evaluated by health providers as mortality, recurrence, performance, and morbidity. Because mortality and recurrence are rare events, evaluation has to focus on performance and morbidity. The latter has mostly been reported by health providers. In the present study, we validate 2 new scales for patient-assessed performance and morbidity in comparison with different outcome tools, such as quality of life (QOL) (European Quality of Life-5 dimensions [EQ-5D]), facial nerve score, and work capacity. There were 167 total patients in a retrospective (n = 90) and prospective (n = 50) cohort of surgically treated vestibular schwannomas. A new patient-assessed morbidity score (paMS), a patient-assessed Karnofsky score (paKPS), the patient-assessed QOL (EQ-5D) score, work capacity, and the House-Brackmann facial nerve score were used as outcome measures. Analysis of paMS components and their relation to other outcomes was done as uni- and multivariate analysis. All outcome instruments, except EQ-5D and paKPS, showed a significant decrease postoperatively. Only the facial nerve score (House-Brackmann facial nerve score) differed significantly between the retrospective and prospective cohorts. Out of the 16 components of the paMS, hearing dysfunction, tear dysfunction, balance dysfunction, and eye irritation were most often reported. Both paMS and EQ-5D correlated significantly with work capacity. Standard QOL and performance instruments may not be sufficiently sensitive or specific to measure outcome at the cohort level after surgical treatment of vestibular schwannomas. A morbidity score may yield more detailed information on symptoms that can be relevant for rehabilitation and occupational training after surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Biogeochemical linkage between atmosphere and ocean in the eastern equatorial Pacific Ocean: Results from the EqPOS research cruise

    Science.gov (United States)

    Furutani, H.; Inai, Y.; Aoki, S.; Honda, H.; Omori, Y.; Tanimoto, H.; Iwata, T.; Ueda, S.; Miura, K.; Uematsu, M.

    2012-12-01

    Eastern equatorial Pacific Ocean is a unique oceanic region from several biogeochemical points of view. It is a remote open ocean with relatively high marine biological activity, which would result in limited influence of human activity but enhanced effect of marine natural processes on atmospheric composition. It is also characterized as high nutrient low chlorophyll (HNLC) ocean, in which availability of trace metals such as iron and zinc limits marine primary production and thus atmospheric deposition of these trace elements to the ocean surface is expected to play an important role in regulating marine primary production and defining unique microbial community. High sea surface temperature in the region generates strong vertical air convection which efficiently brings tropospheric atmospheric composition into stratosphere. In this unique eastern equatorial Pacific Ocean, EqPOS (Equatorial Pacific Ocean and Stratospheric/Tropospheric Atmospheric Study) research cruise was organized as a part of SOLAS Japan activity to understand biogeochemical ocean-atmospheric interaction in the region. Coordinated atmospheric, oceanic, and marine biological observations including sampling/characterization of thin air-sea interfacial layer (sea surface microlayer: SML) and launching large stratospheric air sampling balloons were carried out on-board R/V Hakuho Maru starting from 29 January for 39 days. Biogeochemically important trace/long-lived gases such as CO2, dimethyl sulfide (DMS), and some volatile organic carbons (VOCs) both in the atmosphere and seawater were continuously monitored and their air-sea fluxes were also observed using gradient and eddy-covariance techniques. Atmospheric gas measurement of CO2, CH4, N2O, SF6, CO, H2, Ar and isotopic composition of selected gases were further extended to stratospheric air by balloon-born sampling in addition to a vertical profiling of O3, CO2, and H2O with sounding sondes. Physical and chemical properties of marine

  10. Accumulation of MS2, GA, and Qβ phages on high density polyethylene (HDPE) and drinking water biofilms under flow/non-flow conditions.

    Science.gov (United States)

    Pelleïeux, Sandra; Bertrand, Isabelle; Skali-Lami, Salaheddine; Mathieu, Laurence; Francius, Grégory; Gantzer, Christophe

    2012-12-01

    Accumulation of enteric viruses on surfaces within a drinking water distribution system was investigated in a reactor using three F-specific RNA bacteriophages (MS2, GA, and Qβ) as models of human pathogenic viruses. The influence of hydrodynamic versus hydrostatic conditions and the effect of the colonization of HDPE surfaces with two-month-old biofilms were assessed for virus accumulation on surfaces. In order to work under controlled laminar conditions and to study various wall shear stresses at the same time, a new rotating disc reactor was designed. Among the wall shear rates applied in the reactor (450 to 1640 s(-1)) no significant differences were observed concerning both the total number of bacteria, which was found to be around 1.7 × 10(7) cells/cm(2) and the virus concentrations on surfaces were about 3 × 10(4), 5 × 10(5) and 3 × 10(5) eq PFU/cm(2) for MS2, GA and Qβ phages, respectively. Comparison between static versus dynamic conditions revealed that both Brownian diffusion and convective diffusion were involved in the transport of these soft colloidal particles and an increase reaching about 1 log in virus concentrations measured on surfaces appeared when hydrodynamic conditions where applied. Our results also showed the influence of the colonization by two-month-old drinking water biofilms which led to a change in the level of virus adhesion. The implication of the physico-chemical properties was also underlined since different adhesion profiles were obtained for the three bacteriophages and MS2 phage was found to be the less adherent one whatever the conditions applied. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. msBiodat analysis tool, big data analysis for high-throughput experiments.

    Science.gov (United States)

    Muñoz-Torres, Pau M; Rokć, Filip; Belužic, Robert; Grbeša, Ivana; Vugrek, Oliver

    2016-01-01

    Mass spectrometry (MS) are a group of a high-throughput techniques used to increase knowledge about biomolecules. They produce a large amount of data which is presented as a list of hundreds or thousands of proteins. Filtering those data efficiently is the first step for extracting biologically relevant information. The filtering may increase interest by merging previous data with the data obtained from public databases, resulting in an accurate list of proteins which meet the predetermined conditions. In this article we present msBiodat Analysis Tool, a web-based application thought to approach proteomics to the big data analysis. With this tool, researchers can easily select the most relevant information from their MS experiments using an easy-to-use web interface. An interesting feature of msBiodat analysis tool is the possibility of selecting proteins by its annotation on Gene Ontology using its Gene Id, ensembl or UniProt codes. The msBiodat analysis tool is a web-based application that allows researchers with any programming experience to deal with efficient database querying advantages. Its versatility and user-friendly interface makes easy to perform fast and accurate data screening by using complex queries. Once the analysis is finished, the result is delivered by e-mail. msBiodat analysis tool is freely available at http://msbiodata.irb.hr.

  12. Integrated Balanced FETs for Broadband Millimeter Wave Amplifiers.

    Science.gov (United States)

    1981-08-01

    F. Podell , "A Functional GaAs FET Noise Model," IEEE Trans. ED- 28, 511 (1981). 4. H. Fukui, "Optimal Noise Figure of Microwave GaAs MESFETs," IEEE...Nm = rl Cs2 Req Cgs2 eq rll gs eq) where gmLs rl=r + ms - real part ofZlCgs m d r r req =4kTBgm2 Podell has found empirically for one-micron gate

  13. Practical approaches to the ESI-MS analysis of catalytic reactions.

    Science.gov (United States)

    Yunker, Lars P E; Stoddard, Rhonda L; McIndoe, J Scott

    2014-01-01

    Electrospray ionization mass spectrometry (ESI-MS) is a soft ionization technique commonly coupled with liquid or gas chromatography for the identification of compounds in a one-time view of a mixture (for example, the resulting mixture generated by a synthesis). Over the past decade, Scott McIndoe and his research group at the University of Victoria have developed various methodologies to enhance the ability of ESI-MS to continuously monitor catalytic reactions as they proceed. The power, sensitivity and large dynamic range of ESI-MS have allowed for the refinement of several homogenous catalytic mechanisms and could potentially be applied to a wide range of reactions (catalytic or otherwise) for the determination of their mechanistic pathways. In this special feature article, some of the key challenges encountered and the adaptations employed to counter them are briefly reviewed. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Complementarity of SOMAscan to LC-MS/MS and RNA-seq for quantitative profiling of human embryonic and mesenchymal stem cells.

    Science.gov (United States)

    Billing, Anja M; Ben Hamidane, Hisham; Bhagwat, Aditya M; Cotton, Richard J; Dib, Shaima S; Kumar, Pankaj; Hayat, Shahina; Goswami, Neha; Suhre, Karsten; Rafii, Arash; Graumann, Johannes

    2017-01-06

    Dynamic range limitations are challenging to proteomics, particularly in clinical samples. Affinity proteomics partially overcomes this, yet suffers from dependence on reagent quality. SOMAscan, an aptamer-based platform for over 1000 proteins, avoids that issue using nucleic acid binders. Targets include low expressed proteins not easily accessible by other approaches. Here we report on the potential of SOMAscan for the study of differently sourced mesenchymal stem cells (MSC) in comparison to LC-MS/MS and RNA sequencing. While targeting fewer analytes, SOMAscan displays high precision and dynamic range coverage, allowing quantification of proteins not measured by the other platforms. Expression between cell types (ESC and MSC) was compared across techniques and uncovered the expected large differences. Sourcing was investigated by comparing subtypes: bone marrow-derived, standard in clinical studies, and ESC-derived MSC, thought to hold similar potential but devoid of inter-donor variability and proliferating faster in vitro. We confirmed subtype-equivalency, as well as vesicle and extracellular matrix related processes in MSC. In contrast, the proliferative nature of ESC was captured less by SOMAscan, where nuclear proteins are underrepresented. The complementary of SOMAscan allowed the comprehensive exploration of CD markers and signaling molecules, not readily accessible otherwise and offering unprecedented potential in subtype characterization. Mesenchymal stem cells (MSC) represent promising stem cell-derived therapeutics as indicated by their application in >500 clinical trials currently registered with the NIH. Tissue-derived MSC require invasive harvesting and imply donor-to-donor differences, to which embryonic stem cell (ESC)-derived MSC may provide an alternative and thus warrant thorough characterization. In continuation of our previous study where we compared in depth embryonic stem cells (ESC) and MSC from two sources (bone marrow and ESC

  15. Reference bias: presentation of extreme health states prior to eq-vas improves health-related quality of life scores. a randomised cross-over trial

    Directory of Open Access Journals (Sweden)

    McPhail Steven

    2010-12-01

    Full Text Available Abstract Background Clinical practice and clinical research has made a concerted effort to move beyond the use of clinical indicators alone and embrace patient focused care through the use of patient reported outcomes such as health-related quality of life. However, unless patients give consistent consideration to the health states that give meaning to measurement scales used to evaluate these constructs, longitudinal comparison of these measures may be invalid. This study aimed to investigate whether patients give consideration to a standard health state rating scale (EQ-VAS and whether consideration of good and poor health state descriptors immediately changes their self-report. Methods A randomised crossover trial was implemented amongst hospitalised older adults (n = 151. Patients were asked to consider descriptions of extremely good (Description-A and poor (Description-B health states. The EQ-VAS was administered as a self-report at baseline, after the first descriptors (A or B, then again after the remaining descriptors (B or A respectively. At baseline patients were also asked if they had considered either EQ-VAS anchors. Results Overall 106/151 (70% participants changed their self-evaluation by ≥5 points on the 100 point VAS, with a mean (SD change of +4.5 (12 points (p Conclusions Health state self-reports may not be well considered. An immediate significant shift in response can be elicited by exposure to a mere description of an extreme health state despite no actual change in underlying health state occurring. Caution should be exercised in research and clinical settings when interpreting subjective patient reported outcomes that are dependent on brief anchors for meaning. Trial Registration Australian and New Zealand Clinical Trials Registry (#ACTRN12607000606482 http://www.anzctr.org.au

  16. Determination of drug residues by CLAR-MS/MS in animal tissues

    International Nuclear Information System (INIS)

    Brenes Jimenez, Jose Eduardo

    2009-01-01

    Produced food of animal origin, present the possibility of occurrence of any contact with substances that have negative effects on the health of people who consume them. The use of drugs in veterinary medicine is one of the possible sources of such waste; so, the conditions for the analysis of some classes of antibiotics in animal tissues are based on the study. Costa Rica and the countries that are export destination, have regulation and programs for control before to be distributed in local markets, or post if it is received any complaint of pollution. The high resolution liquid chromatography coupled to mass spectrometers (CLAR-MS/MS) allows the analysis of analytes monitored, according to the specifications required by the legislation. The cases of two laboratories in Costa Rica are presented as the only ones who have the ability to perform the analysis of drug residues CLAR-MS/MS. (author) [es

  17. Study of exhaled breath condensate sample preparation for metabolomics analysis by LC-MS/MS in high resolution mode.

    Science.gov (United States)

    Fernández-Peralbo, M A; Calderón Santiago, M; Priego-Capote, F; Luque de Castro, M D

    2015-11-01

    Metabolomic analysis of exhaled breath condensate (EBC) requires an unavoidable sample preparation step because of the low concentration of its components, and potential cleanup for possible interferents. Sample preparation based on protein precipitation (PP), solid-phase extraction (SPE) by hydrophilic and lipophilic sorbents or lyophilization has demonstrated that the analytical sample from the last is largely the best because lyophilization allows reconstitution in a volume as small as required (preconcentration factors up to 80-times with respect to the original sample), thus doubling the number of detected compounds as compared with the other alternatives (47 versus 25). In addition, PP and/or SPE cleanup are unnecessary as no effect from the EBC components removed by these steps appears in the chromatograms. The total 49 EBC compounds tentatively identified and confirmed by MS/MS in this research include amino acids, fatty acids, fatty amides, fatty aldehydes, sphingoid bases, oxoanionic compounds, imidazoles, hydroxy acids and aliphatic acyclic acids. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. MS2Analyzer: A Software for Small Molecule Substructure Annotations from Accurate Tandem Mass Spectra

    Science.gov (United States)

    2015-01-01

    Systematic analysis and interpretation of the large number of tandem mass spectra (MS/MS) obtained in metabolomics experiments is a bottleneck in discovery-driven research. MS/MS mass spectral libraries are small compared to all known small molecule structures and are often not freely available. MS2Analyzer was therefore developed to enable user-defined searches of thousands of spectra for mass spectral features such as neutral losses, m/z differences, and product and precursor ions from MS/MS spectra in MSP/MGF files. The software is freely available at http://fiehnlab.ucdavis.edu/projects/MS2Analyzer/. As the reference query set, 147 literature-reported neutral losses and their corresponding substructures were collected. This set was tested for accuracy of linking neutral loss analysis to substructure annotations using 19 329 accurate mass tandem mass spectra of structurally known compounds from the NIST11 MS/MS library. Validation studies showed that 92.1 ± 6.4% of 13 typical neutral losses such as acetylations, cysteine conjugates, or glycosylations are correct annotating the associated substructures, while the absence of mass spectra features does not necessarily imply the absence of such substructures. Use of this tool has been successfully demonstrated for complex lipids in microalgae. PMID:25263576

  19. A Computational Framework for Proteome-Wide Pursuit and Prediction of Metalloproteins using ICP-MS and MS/MS Data

    Directory of Open Access Journals (Sweden)

    Trauger Sunia A

    2011-02-01

    Full Text Available Abstract Background Metal-containing proteins comprise a diverse and sizable category within the proteomes of organisms, ranging from proteins that use metals to catalyze reactions to proteins in which metals play key structural roles. Unfortunately, reliably predicting that a protein will contain a specific metal from its amino acid sequence is not currently possible. We recently developed a generally-applicable experimental technique for finding metalloproteins on a genome-wide scale. Applying this metal-directed protein purification approach (ICP-MS and MS/MS based to the prototypical microbe Pyrococcus furiosus conclusively demonstrated the extent and diversity of the uncharacterized portion of microbial metalloproteomes since a majority of the observed metal peaks could not be assigned to known or predicted metalloproteins. However, even using this technique, it is not technically feasible to purify to homogeneity all metalloproteins in an organism. In order to address these limitations and complement the metal-directed protein purification, we developed a computational infrastructure and statistical methodology to aid in the pursuit and identification of novel metalloproteins. Results We demonstrate that our methodology enables predictions of metal-protein interactions using an experimental data set derived from a chromatography fractionation experiment in which 870 proteins and 10 metals were measured over 2,589 fractions. For each of the 10 metals, cobalt, iron, manganese, molybdenum, nickel, lead, tungsten, uranium, vanadium, and zinc, clusters of proteins frequently occurring in metal peaks (of a specific metal within the fractionation space were defined. This resulted in predictions that there are from 5 undiscovered vanadium- to 13 undiscovered cobalt-containing proteins in Pyrococcus furiosus. Molybdenum and nickel were chosen for additional assessment producing lists of genes predicted to encode metalloproteins or metalloprotein

  20. Novel Acoustic Loading of a Mass Spectrometer: Toward Next-Generation High-Throughput MS Screening.

    Science.gov (United States)

    Sinclair, Ian; Stearns, Rick; Pringle, Steven; Wingfield, Jonathan; Datwani, Sammy; Hall, Eric; Ghislain, Luke; Majlof, Lars; Bachman, Martin

    2016-02-01

    High-throughput, direct measurement of substrate-to-product conversion by label-free detection, without the need for engineered substrates or secondary assays, could be considered the "holy grail" of drug discovery screening. Mass spectrometry (MS) has the potential to be part of this ultimate screening solution, but is constrained by the limitations of existing MS sample introduction modes that cannot meet the throughput requirements of high-throughput screening (HTS). Here we report data from a prototype system (Echo-MS) that uses acoustic droplet ejection (ADE) to transfer femtoliter-scale droplets in a rapid, precise, and accurate fashion directly into the MS. The acoustic source can load samples into the MS from a microtiter plate at a rate of up to three samples per second. The resulting MS signal displays a very sharp attack profile and ions are detected within 50 ms of activation of the acoustic transducer. Additionally, we show that the system is capable of generating multiply charged ion species from simple peptides and large proteins. The combination of high speed and low sample volume has significant potential within not only drug discovery, but also other areas of the industry. © 2015 Society for Laboratory Automation and Screening.

  1. Metabolomic and elemental analysis of camel and bovine urine by GC-MS and ICP-MS.

    Science.gov (United States)

    Ahamad, Syed Rizwan; Alhaider, Abdul Qader; Raish, Mohammad; Shakeel, Faiyaz

    2017-01-01

    Recent studies from the author's laboratory indicated that camel urine possesses antiplatelet activity and anti-cancer activity which is not present in bovine urine. The objective of this study is to compare the volatile and elemental components of bovine and camel urine using GC-MS and ICP-MS analysis. We are interested to know the component that performs these biological activities. The freeze dried urine was dissolved in dichloromethane and then derivatization process followed by using BSTFA for GC-MS analysis. Thirty different compounds were analyzed by the derivatization process in full scan mode. For ICP-MS analysis twenty eight important elements were analyzed in both bovine and camel urine. The results of GC-MS and ICP-MS analysis showed marked difference in the urinary metabolites. GC-MS evaluation of camel urine finds a lot of products of metabolism like benzene propanoic acid derivatives, fatty acid derivatives, amino acid derivatives, sugars, prostaglandins and canavanine. Several research reports reveal the metabolomics studies on camel urine but none of them completely reported the pharmacology related metabolomics. The present data of GC-MS suggest and support the previous studies and activities related to camel urine.

  2. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    OpenAIRE

    Haneef, Jamshed; Shaharyar, Mohammad; Husain, Asif; Rashid, Mohd; Mishra, Ravinesh; Parveen, Shama; Ahmed, Niyaz; Pal, Manoj; Kumar, Deepak

    2013-01-01

    Liquid chromatography tandem mass chromatography (LCâMS/MS) is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LCâMS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase) as well as different acquisiti...

  3. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    OpenAIRE

    Haneef, Jamshed; Shaharyar, Mohammad; Husain, Asif; Rashid, Mohd; Mishra, Ravinesh; Parveen, Shama; Ahmed, Niyaz; Pal, Manoj; Kumar, Deepak

    2013-01-01

    Liquid chromatography tandem mass chromatography (LC–MS/MS) is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LC–MS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase) as well as different acquisiti...

  4. Ms2lda.org: web-based topic modelling for substructure discovery in mass spectrometry.

    Science.gov (United States)

    Wandy, Joe; Zhu, Yunfeng; van der Hooft, Justin J J; Daly, Rónán; Barrett, Michael P; Rogers, Simon

    2017-09-14

    We recently published MS2LDA, a method for the decomposition of sets of molecular fragment data derived from large metabolomics experiments. To make the method more widely available to the community, here we present ms2lda.org, a web application that allows users to upload their data, run MS2LDA analyses and explore the results through interactive visualisations. Ms2lda.org takes tandem mass spectrometry data in many standard formats and allows the user to infer the sets of fragment and neutral loss features that co-occur together (Mass2Motifs). As an alternative workflow, the user can also decompose a dataset onto predefined Mass2Motifs. This is accomplished through the web interface or programmatically from our web service. The website can be found at http://ms2lda.org , while the source code is available at https://github.com/sdrogers/ms2ldaviz under the MIT license. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  5. Improved LC-MS/MS method for the quantification of hepcidin-25 in clinical samples.

    Science.gov (United States)

    Abbas, Ioana M; Hoffmann, Holger; Montes-Bayón, María; Weller, Michael G

    2018-06-01

    Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the "sticky" character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing a LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend a LC-MS/MS-based quantification method with a dynamic range of 0.5-40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials. Graphical abstract Structure of hepcidin-25 (Protein Data Bank, PDB ID 2KEF).

  6. Contribution to the risk characterization of ciguatoxins: LOAEL estimated from eight ciguatera fish poisoning events in Guadeloupe (French West Indies).

    Science.gov (United States)

    Hossen, Virginie; Soliño, Lucia; Leroy, Patricia; David, Eric; Velge, Pierre; Dragacci, Sylviane; Krys, Sophie; Flores Quintana, Harold; Diogène, Jorge

    2015-11-01

    From 2010 to 2012, 35 ciguatera fish poisoning (CFP) events involving 87 individuals who consumed locally-caught fish were reported in Guadeloupe (French West Indies). For 12 of these events, the presence of ciguatoxins (CTXs) was indicated in meal remnants and in uncooked fish by the mouse bioassay (MBA). Caribbean ciguatoxins (C-CTXs) were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Using a cell-based assay (CBA), and the only available standard Pacific ciguatoxin-1 (P-CTX-1), the lowest toxins level detected in fish samples causing CFP was 0.022 µg P-CTX-1 equivalent (eq.)·kg(-1) fish. Epidemiological and consumption data were compiled for most of the individuals afflicted, and complete data for establishing the lowest observable adverse effects level (LOAEL) were obtained from 8 CFP events involving 21 individuals. Based on toxin intakes, the LOAEL was estimated at 4.2 ng P-CTX-1 eq./individual corresponding to 48. 4 pg P-CTX-1 eq.kg(-1) body weight (bw). Although based on limited data, these results are consistent with the conclusions of the European Food Safety Authority (EFSA) opinion which indicates that a level of 0.01 µg P-CTX-1 eq.kg(-1) fish, regardless of source, should not exert effects in sensitive individuals when consuming a single meal. The calculated LOAEL is also consistent with the U.S. Food and Drug Administration guidance levels for CTXs (0.1 µg C-CTX-1 eq.kg(-1) and 0.01 µg P-CTX-1 eq.kg(-1) fish). Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Clinicians Publications for Your Patients MS Navigator Program Programs and Services for Your Patients Contact Us Clinical Fellows ... Relapsing-remitting MS (RRMS) Relapsing-remitting ...

  8. Eqüidade na legislação: um princípio do sistema de saúde brasileiro? Equity in law: a Brazilian health system's principle?

    Directory of Open Access Journals (Sweden)

    Cristina Maria Rabelais Duarte

    2000-01-01

    Full Text Available Este artigo procura delinear a concepção inerente à legislação brasileira e apontar possíveis conseqüências da reforma do setor proposta pelo atual governo. Após uma abordagem conceitual do termo eqüidade, os textos da Constituição Federal e Leis Complementares são avaliados. Em seguida, assumindo que os mecanismos de repasse de verbas do governo federal para os municípios funcionam como instrumentos de redistribuição - ou não - de recursos, são analisados aqueles implementados pelas Normas Operacionais Básicas, considerando sua capacidade de promoção de eqüidade. Uma visão panorâmica das propostas de reforma do sistema de saúde atualmente em debate e do papel desempenhado pelo setor privado de assistência é proporcionada, procurando-se enfatizar suas implicações sobre a eqüidade. À guisa de conclusão, resgata-se que as profundas desigualdades sociais existentes no Brasil exigem políticas pautadas em princípios de solidariedade e eqüidade. Neste sentido, a Constituição e Leis Orgânicas são avançadas e a normatização atual, embora ainda distante de concretizar os ditames constitucionais, apresenta progressos nesta direção.This article intends to delineate the definition accept in Brazilian legislation and put in question possible results of the setorial reform suggest by actual government. After a conceptual approach, the Magna Charta and Complementary Laws are analyzed. Following, assuming that the budget repass from federal to municipality government are instruments - or not - of redistribution, those mechanisms implemented by "Normas Operacionais Básicas" are analyzed, considering their capacity of promote equity. A panoramic view about reform health system reform proposes and the role of health private sector emphasizes the implications on equity. In conclusions, it's indicated that the extent of social inequalities in Brazil demand politics engaged with solidarity and equity. The Magna Charta and

  9. Constraining Stellar Coronal Mass Ejections through Multi-wavelength Analysis of the Active M Dwarf EQ Peg

    Science.gov (United States)

    Crosley, M. K.; Osten, R. A.

    2018-03-01

    Stellar coronal mass ejections remain experimentally unconstrained, unlike their stellar flare counterparts, which are observed ubiquitously across the electromagnetic spectrum. Low-frequency radio bursts in the form of a type II burst offer the best means of identifying and constraining the rate and properties of stellar CMEs. CME properties can be further improved through the use of proposed solar-stellar scaling relations and multi-wavelength observations of CMEs through the use of type II bursts and the associated flares expected to occur alongside them. We report on 20 hr of observation of the nearby, magnetically active, and well-characterized M dwarf star EQ Peg. The observations are simultaneously observed with the Jansky Very Large Array at their P-band (230–470 MHz) and at the Apache Point observatory in the SDSS u‧ filter (λ = 3557 Å). Dynamic spectra of the P-band data, constructed to search for signals in the frequency-time domains, did not reveal evidence of drifting radio bursts that could be ascribed to type II bursts. Given the sensitivity of our observations, we are able to place limits on the brightness temperature and source size of any bursts that may have occurred. Using solar scaling rations on four observed stellar flares, we predict CME parameters. Given the constraints on coronal density and photospheric field strength, our models suggest that the observed flares would have been insufficient to produce detectable type II bursts at our observed frequencies. We consider the implications of these results, and other recent findings, on stellar mass loss.

  10. The EIPeptiDi tool: enhancing peptide discovery in ICAT-based LC MS/MS experiments

    Directory of Open Access Journals (Sweden)

    Tradigo Giuseppe

    2007-07-01

    Full Text Available Abstract Background Isotope-coded affinity tags (ICAT is a method for quantitative proteomics based on differential isotopic labeling, sample digestion and mass spectrometry (MS. The method allows the identification and relative quantification of proteins present in two samples and consists of the following phases. First, cysteine residues are either labeled using the ICAT Light or ICAT Heavy reagent (having identical chemical properties but different masses. Then, after whole sample digestion, the labeled peptides are captured selectively using the biotin tag contained in both ICAT reagents. Finally, the simplified peptide mixture is analyzed by nanoscale liquid chromatography-tandem mass spectrometry (LC-MS/MS. Nevertheless, the ICAT LC-MS/MS method still suffers from insufficient sample-to-sample reproducibility on peptide identification. In particular, the number and the type of peptides identified in different experiments can vary considerably and, thus, the statistical (comparative analysis of sample sets is very challenging. Low information overlap at the peptide and, consequently, at the protein level, is very detrimental in situations where the number of samples to be analyzed is high. Results We designed a method for improving the data processing and peptide identification in sample sets subjected to ICAT labeling and LC-MS/MS analysis, based on cross validating MS/MS results. Such a method has been implemented in a tool, called EIPeptiDi, which boosts the ICAT data analysis software improving peptide identification throughout the input data set. Heavy/Light (H/L pairs quantified but not identified by the MS/MS routine, are assigned to peptide sequences identified in other samples, by using similarity criteria based on chromatographic retention time and Heavy/Light mass attributes. EIPeptiDi significantly improves the number of identified peptides per sample, proving that the proposed method has a considerable impact on the protein

  11. Isotope ratio monitoring LC/MS (IRM-LC/MS): new applications

    International Nuclear Information System (INIS)

    Juchelka, D; Hilkert, A.; Krummen, M.

    2005-01-01

    With the introduction of compound specific isotope analysis by isotope ratio monitoring GC/ MS (IRM-GC/MS) the immediate demand for similar applications using HPLC was created. Many compounds of biological, medical, pharmaceutical and environmental interest are not volatile or too polar. Consequently, they cannot be directly analyzed by gas chromatography. In IRM-GC/MS the carrier is helium, which does not interfere with the essential combust ion step prior to isotope ratio mass spectrometry (IRMS). In opposite the LC mobile phase has inhibited a similar direct conversion up to now. All earlier IRM-LC/MS approaches were based on the removal of the liquid phase prior to combustion risking fractionation of the isotope ratios of the eluted compounds. To avoid such restrictions we developed a new continuous flow concept for the coupling of an HPLC system to the isotope ratio MS for 13 C/ 12C isotope ratio analysis. In the Finnigan LC IsoLink, the liquid phase is not removed from the sample prior to oxidation. The sample is oxidized still in the mobile phase followed by on-line separation of the CO 2 from the liquid phase and transfer into the isotope ratio MS. Therefore, this strategy is based on water and inorganic buffers as mobile phase. The new approach opens up a whole new world in the application of gas isotope ratio mass spectrometry. The 13 C/ 12 C ratio s of organic acids, amino acids, carbohydrates and nucleotides can now be measured. These components typically within a complex matrix are separated by liquid chromatography followed by on-line determination of the isotope ratios. The draw backs of using derivatization and off-line preparation procedures can now be over come. This new technique allow s studying biochemical cycles, running tracer experiments and determining the origin of components. Applications from different scientific areas such as biogeochemistry, molecular biology, and pharmacy as well as authenticity control o f foods will be presented

  12. Application of survival analysis methodology to the quantitative analysis of LC-MS proteomics data

    KAUST Repository

    Tekwe, C. D.

    2012-05-24

    MOTIVATION: Protein abundance in quantitative proteomics is often based on observed spectral features derived from liquid chromatography mass spectrometry (LC-MS) or LC-MS/MS experiments. Peak intensities are largely non-normal in distribution. Furthermore, LC-MS-based proteomics data frequently have large proportions of missing peak intensities due to censoring mechanisms on low-abundance spectral features. Recognizing that the observed peak intensities detected with the LC-MS method are all positive, skewed and often left-censored, we propose using survival methodology to carry out differential expression analysis of proteins. Various standard statistical techniques including non-parametric tests such as the Kolmogorov-Smirnov and Wilcoxon-Mann-Whitney rank sum tests, and the parametric survival model and accelerated failure time-model with log-normal, log-logistic and Weibull distributions were used to detect any differentially expressed proteins. The statistical operating characteristics of each method are explored using both real and simulated datasets. RESULTS: Survival methods generally have greater statistical power than standard differential expression methods when the proportion of missing protein level data is 5% or more. In particular, the AFT models we consider consistently achieve greater statistical power than standard testing procedures, with the discrepancy widening with increasing missingness in the proportions. AVAILABILITY: The testing procedures discussed in this article can all be performed using readily available software such as R. The R codes are provided as supplemental materials. CONTACT: ctekwe@stat.tamu.edu.

  13. Ms. Mentor Unmasked

    Science.gov (United States)

    Krebs, Paula

    2008-01-01

    This article presents an interview with Emily Toth, who writes the monthly "Ms. Mentor" academic advice column in the "Chronicle of Higher Education" and teaches in the English department at Louisiana State University, in Baton Rouge. She is the author of "Ms. Mentor's Impeccable Advice for Women in Academia" (1997), "Inside Peyton Place: The Life…

  14. Effective application of freezing lipid precipitation and SCX-SPE for determination of pyrrolizidine alkaloids in high lipid foodstuffs by LC-ESI-MS/MS.

    Science.gov (United States)

    Yoon, Soo Hwan; Kim, Min-Sun; Kim, Sang Hoon; Park, Hyun Mee; Pyo, Heesoo; Lee, Yong Moon; Lee, Kyung-Tae; Hong, Jongki

    2015-06-15

    Pyrrolizidine alkaloids (PAs) are naturally occurring plant toxins associated with serious hepatic disease in humans and animals. In this study, rapid and sensitive analytical method was developed for the determination of 9 toxic PAs in popularly high lipid foodstuffs by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). PAs in lipid foodstuff were effectively purified by freezing lipid precipitation (FLP) and strong cation exchange (SCX)-solid-phase extraction (SPE). Especially, FLP could easily remove the large amounts of triacylglycerols in the lipid sample extract and effectively combine with SPE cleanup. During the FLP procedure, over 77% of the lipids in the foodstuff extracts were rapidly eliminated without any significant loss of the PAs with over 81% recovery. The elimination efficiency of lipids by FLP was tested with LC-atmospheric chemical ionization (APCI)-MS. For further purification, SCX-SPE cartridge could successfully purify PAs from the remaining interfering substances by the variation pH with 5% NH4OH in methanol. For precise quantification and confirmation of PAs in complicate sample matrices, appropriate transition ions in LC-MS/MS-multiple-ion reaction monitoring (MRM) mode were selected on the basis of MS/MS fragmentation pathways of PAs. The established analytical method was validated in terms of the linearity, limits of detection (LOD), and quantification (LOQ), precision, and accuracy. The method was deemed satisfactory by inter- and intra-day validation and exhibited both high accuracy and precision (relative standard deviation<11.06%). Overall limits of detection and quantitation of PAs were approximately 0.06-0.60ng/mL at a signal-to-noise ratio (S/N) of 3 and were about 0.20-1.99ng/mL at a S/N of 10 for all foodstuffs. The established method was successfully applied for the monitoring of toxic PAs in several types of high lipid foodstuffs such as soybeans, seed oil, milk, and margarine. Copyright

  15. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Your Practice Publications for Clinicians Publications for Your Patients MS Navigator Program Programs and Services for Your Patients Contact Us Clinical Fellows d Careers in MS ...

  16. Lung Cancer Serum Biomarker Discovery Using Label Free LC-MS/MS

    Science.gov (United States)

    Zeng, Xuemei; Hood, Brian L.; Zhao, Ting; Conrads, Thomas P.; Sun, Mai; Gopalakrishnan, Vanathi; Grover, Himanshu; Day, Roger S.; Weissfeld, Joel L.; Wilson, David O.; Siegfried, Jill M.; Bigbee, William L.

    2011-01-01

    Introduction Lung cancer remains the leading cause of cancer-related death with poor survival due to the late stage at which lung cancer is typically diagnosed. Given the clinical burden from lung cancer, and the relatively favorable survival associated with early stage lung cancer, biomarkers for early detection of lung cancer are of important potential clinical benefit. Methods We performed a global lung cancer serum biomarker discovery study using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in a set of pooled non-small cell lung cancer (NSCLC) case sera and matched controls. Immunoaffinity subtraction was used to deplete the top most abundant serum proteins; the remaining serum proteins were subjected to trypsin digestion and analyzed in triplicate by LC-MS/MS. The tandem mass spectrum data were searched against the human proteome database and the resultant spectral counting data were used to estimate the relative abundance of proteins across the case/control serum pools. The spectral counting derived abundances of some candidate biomarker proteins were confirmed with multiple reaction monitoring MS assays. Results A list of 49 differentially abundant candidate proteins was compiled by applying a negative binomial regression model to the spectral counting data (pbiomarkers with statistically significant differential abundance across the lung cancer case/control pools which, when validated, could improve lung cancer early detection. PMID:21304412

  17. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Treating MS Comprehensive Care Find an MS Care Provider Medications Managing Relapses Rehabilitation Complementary & Alternative Medicines For Clinicians Resources & Support Library & Education Programs Find Support Advanced Care ...

  18. Progressive-Relapsing MS (PRMS)

    Science.gov (United States)

    ... Is MS? Types of MS Share this page Facebook Twitter Email ... multiple sclerosis (PRMS) was described in the 1996 disease-course definitions as — steadily worsening neurologic function from the beginning ...

  19. Nuclear EQ sourcebook: A compilation of documents for nuclear equipment qualification

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the nuclear power industry, environmental and seismic qualification of safety-related electrical and instrumentation equipment is collectively known as Equipment Qualification (EQ). Related technology, as well as regulatory requirements, have evolved rapidly during the last 15 years. For environmental qualification, what began in 1971 with one trial-use guide (IEEE Std 323-1971), now stands as a full complement of Nuclear Regulatory Commission (NRC) rules, guides and industry standards. In addition to the Institute of Electrical and Electronics Engineers (IEEE), the American Society of Mechanical Engineers (ASME) has also undertaken development of its own set of standards for use in qualifying safety-related mechanical equipment. To ensure that the original design and qualification is preserved, engineers need to select and use the correct set of NRC regulations, regulatory guides, industry standards, and generic correspondence. Given that the total number of these documents exceed 200, this task becomes resource intensive. This compilation is the first known publication available to serve the user-community need for a complete and exhaustive single source. Approximately 180 items (Bulletins, Federal Rules, Generic Letters, Notices, Regulatory Guides, IEEE Standards, IEEE Recommended Practices, and IEEE Guides) have been processed separately for inclusion on the data base

  20. EPA CRL MS014: Analysis of Aldicarb, Bromadiolone, Carbofuran, Oxamyl and Methomyl in Water by Multiple Reaction Monitoring Liquid Chromatography / Tandem Mass Spectrometry (LC/MS/MS)

    Science.gov (United States)

    Method MS014 describes procedures for solvent extraction of aldicarb, bromadiolone, carbofuran, oxamyl and methomyl from water samples, followed by analysis using liquid chromatography tandem mass spectrometry (LC-MS-MS).

  1. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    Directory of Open Access Journals (Sweden)

    Jamshed Haneef

    2013-10-01

    Full Text Available Liquid chromatography tandem mass chromatography (LC–MS/MS is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LC–MS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase as well as different acquisition modes (SIM, MRM for quantitative analysis of glucocorticoids and stimulants. This review is not meant to be exhaustive but rather to provide a general overview for detection and confirmation of target drugs using LC–MS/MS and thus useful in the doping analysis, toxicological studies as well as in pharmaceutical analysis. Keywords: LC–MS/MS, Ionization techniques, Glucocorticoids, Stimulants, Hyphenated techniques, Biological fluid

  2. MS Windows domēna darbstacijas migrācijas iespējas no MS Windows XP uz MS Windows 7.

    OpenAIRE

    Zariņš, Valdis

    2009-01-01

    Kvalifikācijas darbā tiek aprakstītas MS Windows domēna darbstacijas migrācijas iespējas no MS Windows XP uz MS Windows 7, kā servera operētājsistēmas izmantojot tādus Microsoft produktus, kā Microsoft Windows Server 2003 un Microsoft Windows Server 2008. Kvalifikācijas darba teorētiskaja daļā tiek apskatīti Microsoft Windows 7 priekšrocības un uzlabojumus gan no darbstacijas lietotāja , gan no darbstacijas administratora puses. Ir aprakstītas Microsoft Windows Server 2008 jauninājumu ie...

  3. MALDI-MS drug analysis in biological samples: opportunities and challenges.

    Science.gov (United States)

    Steuer, Andrea E; Poetzsch, Michael; Kraemer, Thomas

    2016-09-01

    Drug analysis represents a large field in different disciplines. Plasma is commonly considered to be the biosample of choice for that purpose. However, concentrations often do not represent the levels present within deeper compartments and therefore cannot sufficiently explain efficacy or toxicology of drugs. MALDI-MS in drug analysis is of great interest for high-throughput quantification and particularly spatially resolved tissue imaging. The current perspective article will deal with challenges and opportunities of MALDI-MS drug analysis in different biological samples. A particular focus will be on hair samples. Recent applications were included, reviewed for their instrumental setup and sample preparation and pros and cons as well as future perspectives are critically discussed.

  4. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Contact Us Newly Diagnosed If you or somone close to you has recently been diagnosed, access our MS information and resources. Start ... Room MS Prevalence Charitable Ratings Corporate Support Helpful Links ...

  5. MS in Your Relationships

    Science.gov (United States)

    ... MS Relationships Share this page Facebook Twitter Email Relationships MS poses additional challenges, but it also enriches ... when it is not. Keeping balance in your relationship When one person in a couple is affected ...

  6. Single-cell analysis by ICP-MS/MS as a fast tool for cellular bioavailability studies of arsenite.

    Science.gov (United States)

    Meyer, S; López-Serrano, A; Mitze, H; Jakubowski, N; Schwerdtle, T

    2018-01-24

    Single-cell inductively coupled plasma mass spectrometry (SC-ICP-MS) has become a powerful and fast tool to evaluate the elemental composition at a single-cell level. In this study, the cellular bioavailability of arsenite (incubation of 25 and 50 μM for 0-48 h) has been successfully assessed by SC-ICP-MS/MS for the first time directly after re-suspending the cells in water. This procedure avoids the normally arising cell membrane permeabilization caused by cell fixation methods (e.g. methanol fixation). The reliability and feasibility of this SC-ICP-MS/MS approach with a limit of detection of 0.35 fg per cell was validated by conventional bulk ICP-MS/MS analysis after cell digestion and parallel measurement of sulfur and phosphorus.

  7. Surtos de tripanossomíase por Trypanosoma evansi em eqüinos no Rio Grande do Sul: aspectos epidemiológicos, clínicos, hematológicos e patológicos Outbreaks of trypanosomiasis in horses by Trypanosoma evansi in the state of Rio Grande do Sul, Brazil: epidemiological, clinical, hematological, and pathological aspects

    Directory of Open Access Journals (Sweden)

    Aline Rodrigues

    2005-12-01

    ão sentado". Os encéfalos de 5 eqüinos com quadro encefálico foram submetidos à técnica de imunoistoquímica estrepto-avidina-biotina; em todos eles observou-se a marcação de números moderados ou elevados de espécimes de T. evansi pelo anticorpo específico nos espaços intravasculares e na neurópila. Os aspectos epidemiológicos, clínicos, hematológicos e patológicos da tripanossomíase por T. evansi em eqüinos são discutidos.Cases of trypanosomiasis by Trypanosoma evansi were diagnosed in horses in the state of Rio Grande do Sul, Brazil, between 2003 and 2004. In one stud farm (Farm A with 125 horses, 52 died. Additionally, around 80 mares were sent to Farm A to be bred. Of those, 66 became ill and 56 died after being returned to their farms of origin. Twenty one horses clinically affected by the disease were observed. Clinical signs included loss of weight (despite voracious appetite, lethargy, incoordination and instability of hindlimbs, atrophy of the large muscles of the hindlimbs, muscle weakness and paleness of mucosae. Specimens of T. evansi were detected in the blood drawn from four affected horses. Normocytic normochromic anemia with PCVs ranging from 15 to 31%, leucocytosis due to lymphocytosis associated to large atypical lymphocytes was observed in several affected horses. High levels of antibodies against T. evansi were detected in the serum of six horses from Farm A. Eight horses presented encephalic neurological signs such as circling, ataxia, blindness, excitation, falls, listlessness, proprioception deficits and head tilt. One horse assumed a "dog-seating position". Necropsy findings included muscle atrophy, enlargement and lymphoid hyperplasia of the spleen and lymphnodes, edema and softening of the white and grey matter of the brain. Histologically, an overwhelming necrotizing panencephalitis was observed in the seven horses with encephalic signs. This panencephalitis was characterized by marked edema, demyelination and necrosis and

  8. An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS.

    Science.gov (United States)

    Young, J Bryce; Li, Liang

    2006-03-01

    A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.

  9. LC-MS/MS Peptide Mapping with Automated Data Processing for Routine Profiling of N-Glycans in Immunoglobulins

    Science.gov (United States)

    Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi

    2014-06-01

    Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.

  10. A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Bozzani Fiammetta Maria

    2012-08-01

    Full Text Available Abstract Background Economic viability of treatments for primary open-angle glaucoma (POAG should be assessed objectively to prioritise health care interventions. This study aims to identify the methods for eliciting utility values (UVs most sensitive to differences in visual field and visual functioning in patients with POAG. As a secondary objective, the dimensions of generic health-related and vision-related quality of life most affected by progressive vision loss will be identified. Methods A total of 132 POAG patients were recruited. Three sets of utility values (EuroQoL EQ-5D, Short Form SF-6D, Time Trade Off and a measure of perceived visual functioning from the National Eye Institute Visual Function Questionnaire (VFQ-25 were elicited during face-to-face interviews. The sensitivity of UVs to differences in the binocular visual field, visual acuity and visual functioning measures was analysed using non-parametric statistical methods. Results Median utilities were similar across Integrated Visual Field score quartiles for EQ-5D (P = 0.08 whereas SF-6D and Time-Trade-Off UVs significantly decreased (p = 0.01 and p = 0.001, respectively. The VFQ-25 score varied across Integrated Visual Field and binocular visual acuity groups and was associated with all three UVs (P ≤ 0.001; most of its vision-specific sub-scales were associated with the vision markers. The most affected dimension was driving. A relationship with vision markers was found for the physical component of SF-36 and not for any dimension of EQ-5D. Conclusions The Time-Trade-Off was more sensitive than EQ-5D and SF-6D to changes in vision and visual functioning associated with glaucoma progression but could not measure quality of life changes in the mildest disease stages.

  11. Does the choice of tariff matter?: A comparison of EQ-5D-5L utility scores using Chinese, UK, and Japanese tariffs on patients with psoriasis vulgaris in Central South China.

    Science.gov (United States)

    Zhao, Yue; Li, Shun-Ping; Liu, Liu; Zhang, Jiang-Lin; Chen, Gang

    2017-08-01

    There is an increasing trend globally to develop country-specific tariffs that can theoretically better reflect population's preferences on health states for preference-based health-related quality-of-life instruments, also known as multiattribute utility instruments. This study focused on the most recently developed 5-level version of EuroQol-5 Dimension (EQ-5D) questionnaire, 1 of the world's most well-known multiattribute utility instruments, and aimed to empirically explore the agreements and known-group validities of applying the country-specific tariff versus tariffs developed from other countries using a sample of psoriasis vulgaris patients in Mainland China.A convenience sampling framework was adopted to recruit patients diagnosed with psoriasis vulgaris from Xiangya Hospital, Central South University, China, between May 2014 and February 2015. The 5-level EuroQol-5 dimensions (EQ-5D-5L) utilities were scored by using the Chinese, Japanese, and UK tariffs. Health state utilities were compared using a range of nonparametric test. The intraclass correlation coefficients and Bland-Altman plots were used to examine the agreements among the 3 EQ-5D-5L scores. Health state utility decrements between known groups were investigated using both effect size and a regression analysis.In all, 350 patients (aged 16 years or older) were recruited. There were significant differences among the 3 national tariff sets. Overall, 3 tariffs showed excellent agreements (intraclass correlation coefficient >0.90); however, the wide limits of agreement from the Bland-Altman plots suggest that these tariffs cannot be used interchangeably. The EQ-5D-5L scores using the Chinese-specific tariff showed the best known-group validity than the other 2 tariffs in this Chinese patient sample. The evidence from this study supports the choice of the country-specific tariff to be used in Mainland China.

  12. Accuracy of the Precision® point-of-care ketone test examined by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in the same fingerstick sample.

    Science.gov (United States)

    Janssen, Marcel J W; Hendrickx, Ben H E; Habets-van der Poel, Carin D; van den Bergh, Joop P W; Haagen, Anton A M; Bakker, Jaap A

    2010-12-01

    The Precision(®) (Abbott Diabetes Care) point-of-care biosensor test strips are widely used by patients with diabetes and clinical laboratories for measurement of plasma β-hydroxybutyrate (β-HB) concentrations in capillary blood samples obtained by fingerstick. In the literature, this procedure has been validated only against the enzymatic determination of β-HB in venous plasma, i.e., the method to which the Precision(®) has been calibrated. In this study, the Precision(®) Xceed was compared to a methodologically different and superior procedure: determination of β-HB by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in capillary blood spots. Blood spots were obtained from the same fingerstick sample from out of which Precision(®) measurements were performed. Linearity was tested by adding varying amounts of standard to an EDTA venous whole blood matrix. The Precision(®) was in good agreement with LC-MS/MS within the measuring range of 0.0-6.0 mmol/L (Passing and Bablok regression: slope=1.20 and no significant intercept, R=0.97, n=59). Surprisingly, the Precision(®) showed non-linearity and full saturation at concentrations above 6.0 mmol/L, which were confirmed by a standard addition experiment. Results obtained at the saturation level varied between 3.0 and 6.5 mmol/L. The Precision(®) β-HB test strips demonstrate good comparison with LC-MS/MS. Inter-individual variation around the saturation level, however, is large. Therefore, we advise reporting readings above 3.0 as >3.0 mmol/L. The test is valid for use in the clinically relevant range of 0.0-3.0 mmol/L.

  13. Investigation of enrofloxacin residues in broiler tissues using ELISA and LC-MS/MS.

    Science.gov (United States)

    Panzenhagen, Pedro Henrique N; Aguiar, Waldemir S; Gouvêa, Raquel; de Oliveira, Andréa M G; Barreto, Fabiano; Pereira, Virgínia L A; Aquino, Maria Helena C

    2016-01-01

    This study investigated the efficiency of an enrofloxacin ELISA test kit to detect the presence of enrofloxacin residues in broiler tissues compared with LC-MS/MS. Broiler tissues from 72 samples consisting of 60 breast muscle, six pools of livers (500 g each) and six pools of kidneys (500 g each) were obtained from six different slaughterhouses. Breast muscle from 10 carcasses and pools of livers and kidneys from approximately 200 carcasses of the same flock were collected from each slaughterhouse. ELISA and HPLC were used to identify and quantify the contamination of the samples with enrofloxacin. A total of 72% of the analysed samples contained enrofloxacin residues detected by the ELISA and 22.2% were detected by LC-MS/MS. The mean values of enrofloxacin contamination found in chicken breast by ELISA and HPLC were 8.63 and 12.25 μg kg(-1), respectively. None of the samples exceeded the maximum limit of 100 μg kg(-1) by both methods set by the European Union as well as the Brazilian Agriculture Ministry. All positive samples for enrofloxacin residues detected by LC-MS/MS were also positive by ELISA. These data confirm the efficiency of the ELISA test, and suggest its use as a screening method for enrofloxacin residues in poultry tissues due to its quick results, low price and ease of applicability.

  14. Relationship between plasma and salivary melatonin and cortisol investigated by LC-MS/MS.

    Science.gov (United States)

    van Faassen, Martijn; Bischoff, Rainer; Kema, Ido P

    2017-08-28

    Disturbance of the circadian rhythm has been associated with disease states, such as metabolic disorders, depression and cancer. Quantification of the circadian markers such as melatonin and cortisol critically depend on reliable and reproducible analytical methods. Previously, melatonin and cortisol were primarily analyzed separately, mainly using immunoassays. Here we describe the validation and application of a high-throughput liquid chromatography in combination with mass spectrometry (LC-MS/MS) method for the combined analysis of melatonin and cortisol in plasma and saliva. The LC-MS/MS method was validated according to international validation guidelines. We used this method to analyze total plasma, free plasma (as obtained by equilibrium dialysis) and saliva melatonin and cortisol in healthy adults. Validation results for plasma and saliva melatonin and cortisol were well within the international validation criteria. We observed no difference between saliva collected by passive drooling or Salivette. Moreover, we noted a significant difference in saliva vs. free plasma melatonin. We observed on average 36% (95% CI: 4%-60%) higher salivary melatonin levels in comparison to free plasma melatonin, suggestive of local production of melatonin in the salivary glands. The novel outcome of this study is probably due to the high precision of our LC-MS/MS assay. These outcomes illustrate the added value of accurate and sensitive mass spectrometry based methods for the quantification of neuroendocrine biomarkers.

  15. Analytical methods for multiresidue determination of sulfonamides and trimethoprim in meat and ground water samples by CE-MS and CE-MS/MS.

    Science.gov (United States)

    Soto-Chinchilla, Jorge J; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2007-11-01

    This paper presents two methods based on CZE-MS detection and CZE-MS/MS detection developed for the multiresidue determination of ten sulfonamides (sulfapyridine, sulfadoxin, sulfamethazine, sulfadimethoxine, sulfameter, sulfamerazine, sulfachlorpyridazine, sulfadiazine, sulfamethoxazole, and sulfamethizole) and a potentiator, trimethoprim (TMP), whose contents are regulated by the EU Council Regulation no. 2377/90 in animal edible tissues. Experimental designs were employed to optimize the electrospray conditions. MS/MS experiments using an IT as analyzer operating in multiple reaction monitoring (MRM) mode were carried out to achieve the minimum number of points according to the 2002/657/EC European Decision for unambiguous identification. The proposed procedures have been compared in terms of the performance characteristics and trueness. The limits of detection and quantification were in all cases lower than the maximum residue limits legislated for these compounds and the recoveries were satisfactory, being possible the application for their monitoring in foodstuff of animal origin and in environmental samples, allowing the determination of sulfonamides and TMP residues in meat and in superficial water in the low microg/L range.

  16. Cross-validated stable-isotope dilution GC-MS and LC-MS/MS assays for monoacylglycerol lipase (MAGL) activity by measuring arachidonic acid released from the endocannabinoid 2-arachidonoyl glycerol.

    Science.gov (United States)

    Kayacelebi, Arslan Arinc; Schauerte, Celina; Kling, Katharina; Herbers, Jan; Beckmann, Bibiana; Engeli, Stefan; Jordan, Jens; Zoerner, Alexander A; Tsikas, Dimitrios

    2017-03-15

    2-Arachidonoyl glycerol (2AG) is an endocannabinoid that activates cannabinoid (CB) receptors CB1 and CB2. Monoacylglycerol lipase (MAGL) inactivates 2AG through hydrolysis to arachidonic acid (AA) and glycerol, thus modulating the activity at CB receptors. In the brain, AA released from 2AG by the action of MAGL serves as a substrate for cyclooxygenases which produce pro-inflammatory prostaglandins. Here we report stable-isotope GC-MS and LC-MS/MS assays for the reliable measurement of MAGL activity. The assays utilize deuterium-labeled 2AG (d 8 -2AG; 10μM) as the MAGL substrate and measure deuterium-labeled AA (d 8 -AA; range 0-1μM) as the MAGL product. Unlabelled AA (d 0 -AA, 1μM) serves as the internal standard. d 8 -AA and d 0 -AA are extracted from the aqueous buffered incubation mixtures by ethyl acetate. Upon solvent evaporation the residue is reconstituted in the mobile phase prior to LC-MS/MS analysis or in anhydrous acetonitrile for GC-MS analysis. LC-MS/MS analysis is performed in the negative electrospray ionization mode by selected-reaction monitoring the mass transitions [M-H] - →[M-H - CO 2 ] - , i.e., m/z 311→m/z 267 for d 8 -AA and m/z 303→m/z 259 for d 0 -AA. Prior to GC-MS analysis d 8 -AA and d 0 -AA were converted to their pentafluorobenzyl (PFB) esters by means of PFB-Br. GC-MS analysis is performed in the electron-capture negative-ion chemical ionization mode by selected-ion monitoring the ions [M-PFB] - , i.e., m/z 311 for d 8 -AA and m/z 303 for d 0 -AA. The GC-MS and LC-MS/MS assays were cross-validated. Linear regression analysis between the concentration (range, 0-1μM) of d 8 -AA measured by LC-MS/MS (y) and that by GC-MS (x) revealed a straight line (r 2 =0.9848) with the regression equation y=0.003+0.898x, indicating a good agreement. In dog liver, we detected MAGL activity that was inhibitable by the MAGL inhibitor JZL-184. Exogenous eicosatetraynoic acid is suitable as internal standard for the quantitative determination

  17. ESI MS/MS Study of Calix[4]arene Derivatives and their Metal Complexes

    OpenAIRE

    Benković, Tomislav; Tomišić, Vladislav; Frkanec, Leo; Galić, Nives

    2012-01-01

    The peptidocalixarenes 1–3 bearing tryptophan, phenylglycine and leucil units at the lower rim and their complexes with alkali-metal (Li+, Na+, K+, Rb+, Cs+) and selected lanthanide cations (La3+, Ce3+, Eu3+, Yb3+) were analyzed by ESI MS. The influences of the solvent (acetonitrile, methanol, addition of formic acid or sodium acetate) and the calixarene:cation molar ratio on signal intensities were investigated. Comprehensive MS/MS analyses were performed of all singly and doubly charged ion...

  18. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Programs and Events Living Well with MS Diet, Exercise & Healthy Behaviors Emotional Well-Being Spiritual Well-Being ... Events d Living Well with MS d Diet, Exercise & Healthy Behaviors Diet & Nutrition Exercise Heat & Temperature Sensitivity ...

  19. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Events Living Well with MS Diet, Exercise & Healthy Behaviors Emotional Well-Being Spiritual Well-Being Cognitive Health ... Living Well with MS d Diet, Exercise & Healthy Behaviors Diet & Nutrition Exercise Heat & Temperature Sensitivity Sleep Vaccinations ...

  20. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Rule Out For Clinicians Treating MS Comprehensive Care Find an MS Care Provider Medications Managing Relapses Rehabilitation ... Medicines For Clinicians Resources & Support Library & Education Programs Find Support Advanced Care Needs Resources for Specific Populations ...

  1. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... bowel and bladder problems, and problems with cognition (learning and memory or information processing). People with progressive ... More The National MS Society is Here to Help Need More Information? We Are Here Our MS ...

  2. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... of Programs and Events Living Well with MS Diet, Exercise & Healthy Behaviors Emotional Well-Being Spiritual Well- ... and Events d Living Well with MS d Diet, Exercise & Healthy Behaviors Diet & Nutrition Exercise Heat & Temperature ...

  3. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... d Spiritual Well-Being Building Spirituality into Your Life d Cognitive Health d Work, Home & Leisure Employment ... Partnership Opportunities d Personal Stories Ambassadors & Familiar Faces Life with MS Givers Shakers Families with MS Seekers ...

  4. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Brochure Working with MS (.pdf) Download Brochure Taming Stress (.pdf) Download Brochure Multiple Sclerosis and Your Emotions (. ... For Professionals Researchers Physicians Nurses Rehabilitation Professionals Mental Health Professionals Health and Wellness Professionals What Is MS? ...

  5. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Online d Give in Honor or Memory d Workplace Giving d Employer Matching Gifts d Gifts of ... Living with MS (.pdf) Download Brochure Focus on Employment (.pdf) Download Brochure Working with MS (.pdf) Download ...

  6. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Life d Cognitive Health d Work, Home & Leisure Employment Insurance & Financial Information Staying Mobile Reclaiming Control Accessibility ... Living with MS (.pdf) Download Brochure Focus on Employment (.pdf) Download Brochure Working with MS (.pdf) Download ...

  7. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... working effectively. How does RRMS differ from progressive types of MS? While RRMS is defined by attacks ... forms of MS involve much less of this type of inflammation. People with RRMS tend to have ...

  8. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... attacks of inflammation (relapses) in the CNS, progressive forms of MS involve much less of this type ... and memory or information processing). People with progressive forms of MS are more likely to experience gradually ...

  9. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Associated Myelopathy (HAM) Neuromyelitis Optica (NMO) Schilder's Disease Transverse Myelitis d Symptoms & Diagnosis d Diagnosing MS d ... Overview (.pdf) Download Document Pediatric MS Learn More Transverse Myelitis Learn More Neuromyelitis Optica (NMO) Learn More ...

  10. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Directors Senior Leadership Team Founder Sylvia Lawry d Cultural Values d Financials Annual Reports Sources of Support ... MS Connection About the Society Vision Careers Leadership Cultural Values Financials News Press Room MS Prevalence Charitable ...

  11. Concentrações sangüíneas de lactato em eqüinos durante a prova de fundo do concurso completo de equitação

    Directory of Open Access Journals (Sweden)

    Gomide Lina Maria Wehrle

    2006-01-01

    Full Text Available Colheu-se sangue de 13 eqüinos competindo na prova de Fundo do Concurso Completo de Equitação, categoria internacional três estrelas, e dosou-se lactato sangüíneo na manhã antes da prova, antes e imediatamente depois das fases B e D e 10 minutos após a fase D. Foi observado aumento significativo nas concentrações de lactato apenas após o término da fase D, demonstrando que os animais foram submetidos a um grande esforço físico, com desenvolvimento de acidose metabólica decorrente do acúmulo de lactato. Houve diminuição significativa dos valores dez minutos após o término do cross-country, exceto para o eqüino de número 12, único animal a completar o percurso dentro do tempo estipulado, o qual apresentou sinais clínicos de exaustão.

  12. A novel study of screening and confirmation of modafinil, adrafinil and their metabolite modafinilic acid under EI-GC-MS and ESI-LC-MS-MS ionization.

    Science.gov (United States)

    Dubey, S; Ahi, S; Reddy, I M; Kaur, T; Beotra, A; Jain, S

    2009-12-01

    Adrafinil and modafinil have received wide publicity and have become controversial in the sporting world when several athletes were discovered allegedly using these drugs as doping agents. By acknowledging the facts, the World Anti-Doping Agency (WADA) banned these drugs in sports since 2004. The present study explores the possibility of differentiating adrafinil and modafinil and their major metabolites under electron impact ionization in gas chromatograph-mass spectrometer (GC-MSD) and electrospray ionization in liquid chromatograph-mass spectrometer (LC-MS/MS) by studying the fragmentation pattern of these drugs. Adrafinil, modafinil and their major metabolite, modafinilic acid were analyzed on EI-GC-MSD and ESI-LC-MS/MS using various individual parameters on both the instruments. The analytical technique and equipment used in the analysis were an Agilent 6890N GC with 5973 mass selective detector for the GC-MSD analysis and an Agilent 1100 HPLC with API-3200 Triple quadrupole mass spectrometer for the LC-MS/MS analysis. Validation of both methods was performed using six replicates at different concentrations. The results show that adrafinil, modafinil and their major metabolite modafinilic acid could be detected as a single artifact without differentiation under EI-GC-MSD analysis. However, all drugs could be detected and differentiated under ESI-LCMS/MS analysis without any artifaction. The GC-MSD analysis gives a single artifact for both the drugs without differentiation and thus can be used as a marker for screening purposes. Further, the Multiple Reaction Monitoring (MRM) method developed under LC-MS/MS is fit for the purpose for confirmation of suspicious samples in routine sports testing and in forensic and clinical analysis.

  13. Quantitative analysis of polyethylene glycol (PEG) and PEGylated proteins in animal tissues by LC-MS/MS coupled with in-source CID.

    Science.gov (United States)

    Gong, Jiachang; Gu, Xiaomei; Achanzar, William E; Chadwick, Kristina D; Gan, Jinping; Brock, Barry J; Kishnani, Narendra S; Humphreys, W Griff; Iyer, Ramaswamy A

    2014-08-05

    The covalent conjugation of polyethylene glycol (PEG, typical MW > 10k) to therapeutic peptides and proteins is a well-established approach to improve their pharmacokinetic properties and diminish the potential for immunogenicity. Even though PEG is generally considered biologically inert and safe in animals and humans, the slow clearance of large PEGs raises concerns about potential adverse effects resulting from PEG accumulation in tissues following chronic administration, particularly in the central nervous system. The key information relevant to the issue is the disposition and fate of the PEG moiety after repeated dosing with PEGylated proteins. Here, we report a novel quantitative method utilizing LC-MS/MS coupled with in-source CID that is highly selective and sensitive to PEG-related materials. Both (40K)PEG and a tool PEGylated protein (ATI-1072) underwent dissociation in the ionization source of mass spectrometer to generate a series of PEG-specific ions, which were subjected to further dissociation through conventional CID. To demonstrate the potential application of the method to assess PEG biodistribution following PEGylated protein administration, a single dose study of ATI-1072 was conducted in rats. Plasma and various tissues were collected, and the concentrations of both (40K)PEG and ATI-1072 were determined using the LC-MS/MS method. The presence of (40k)PEG in plasma and tissue homogenates suggests the degradation of PEGylated proteins after dose administration to rats, given that free PEG was absent in the dosing solution. The method enables further studies for a thorough characterization of disposition and fate of PEGylated proteins.

  14. The APEX Quantitative Proteomics Tool: Generating protein quantitation estimates from LC-MS/MS proteomics results

    Directory of Open Access Journals (Sweden)

    Saeed Alexander I

    2008-12-01

    Full Text Available Abstract Background Mass spectrometry (MS based label-free protein quantitation has mainly focused on analysis of ion peak heights and peptide spectral counts. Most analyses of tandem mass spectrometry (MS/MS data begin with an enzymatic digestion of a complex protein mixture to generate smaller peptides that can be separated and identified by an MS/MS instrument. Peptide spectral counting techniques attempt to quantify protein abundance by counting the number of detected tryptic peptides and their corresponding MS spectra. However, spectral counting is confounded by the fact that peptide physicochemical properties severely affect MS detection resulting in each peptide having a different detection probability. Lu et al. (2007 described a modified spectral counting technique, Absolute Protein Expression (APEX, which improves on basic spectral counting methods by including a correction factor for each protein (called Oi value that accounts for variable peptide detection by MS techniques. The technique uses machine learning classification to derive peptide detection probabilities that are used to predict the number of tryptic peptides expected to be detected for one molecule of a particular protein (Oi. This predicted spectral count is compared to the protein's observed MS total spectral count during APEX computation of protein abundances. Results The APEX Quantitative Proteomics Tool, introduced here, is a free open source Java application that supports the APEX protein quantitation technique. The APEX tool uses data from standard tandem mass spectrometry proteomics experiments and provides computational support for APEX protein abundance quantitation through a set of graphical user interfaces that partition thparameter controls for the various processing tasks. The tool also provides a Z-score analysis for identification of significant differential protein expression, a utility to assess APEX classifier performance via cross validation, and a

  15. Human herpesviruses and MS

    DEFF Research Database (Denmark)

    Christensen, Tove

    2007-01-01

    and they are capable of reactivation. Epstein Barr virus (EBV), HHV-6A and varicella zoster virus (VZV) are consistently linked with MS, particularly with respect to epidemiology, antibody responses in serum (EBV) and cerebrospinal fluid (EBV and HHV-6A), and with MS exacerbations that are associated with viral...... reactivation (VZV, HHV-6A and EBV). HHV have the potential for a causal role in MS--they may be key players in the disease process--and this role could be mediated through several direct or indirect mechanisms....

  16. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... working effectively. How does RRMS differ from progressive types of MS? While RRMS is defined by attacks of ... forms of MS involve much less of this type of inflammation. People with RRMS tend to have more ...

  17. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... More Schilder's Disease Learn More The National MS Society is Here to Help Need More Information? We ... Twitter LinkedIn YouTube Pinterest MS Connection About the Society Vision Careers Leadership Cultural Values Financials News Press ...

  18. Estenose de piloro em eqüino adulto Pyloric stenosis in a mature horse

    Directory of Open Access Journals (Sweden)

    Ana Lúcia Miluzzi Yamada

    2009-02-01

    Full Text Available Neste trabalho, é descrito um caso de estenose hipertrófica de piloro diagnosticado por gastroscopia em um eqüino Quarto de Milha, de quatro anos de idade, que apresentava inapetência, emagrecimento progressivo, cólica, bruxismo e sialorréia. A gastroduodenite ulcerativa crônica e os espasmos prolongados foram as supostas causas da hipertrofia da musculatura circular do piloro, causando a estenose. O tratamento com substâncias antiulcerativas é paliativo e o acesso cirúrgico ao piloro no animal adulto é complexo, sendo o prognóstico duvidoso.A case of hypertrophic pyloric stenosis diagnosed by gastroscopy was reported in a 4-years-old Quarter Horse gelding, with signs of inappetence, chronic weight loss, colic, bruxism and sialorrhea. Gastroduodenal ulceration and spasms were supposed as causes of pyloric muscular hypertrophy and stenosis. Antiulcerative medications are merely palliative and the complex surgical approach to the site of stenosis makes the prognostic to be doubtful.

  19. Quantification of free and total sialic acid excretion by LC-MS/MS

    NARCIS (Netherlands)

    van der Ham, Maria; Prinsen, Berthil H. C. M. T.; Huijmans, Jan G. M.; Abeling, Nicolaas G. G. M.; Dorland, Bert; Berger, Ruud; de Koning, Tom J.; de Sain-van der Velden, Monique G. M.

    2007-01-01

    The main purpose for measuring urinary free sialic acid (FSA) is to diagnose sialic acid (SA) storage diseases. Elevated amounts of conjugated sialic acid (CSA) are observed in several diseases indicating the need to quantify CSA as well. A LC-MS/MS method for quantification of FSA and total sialic

  20. Analysis of aquatic-phase natural organic matter by optimized LDI-MS method

    KAUST Repository

    Wang, Renqi; Druckenmü ller, Katharina; Elbers, Gereon; Guenther, Klaus; Croue, Jean-Philippe

    2014-01-01

    . On the other hand, the waste water and reservoir water mainly had relatively smaller molecules of about 2000 Da. The LDI-MS measurements indicated that highly humic river waters were able to form large aggregates and membrane foulants, while the HPO NOMs from

  1. Diet-induced perturbation of the rat liver mitochondrial acetylome studied by quantitative (iTRAQ) LC-MS/MS

    DEFF Research Database (Denmark)

    León, Ileana R.; Schwämmle, Veit; Williamson, James

    described3. Quantitation by MS/MS was achieved by using iTRAQ 8-Plex reagents (Life Technologies). LC-MS/MS analyses were performed using an Easy-nLC (Proxeon/ThermoFisher) fitted with an in-house made 17 cm C18 column that was interfaced to an LTQ-OrbiTrap XL instrument (ThermoFisher). Data analysis...

  2. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Review of Society's Research Programs d Careers d Leadership Board of Directors Senior Leadership Team Founder Sylvia Lawry d Cultural Values d ... Pinterest MS Connection About the Society Vision Careers Leadership Cultural Values Financials News Press Room MS Prevalence ...

  3. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Another Condition Aging with MS Anesthesia and Surgery Managing Your MS d Emotional Well-Being Mood Changes d Spiritual Well-Being Building Spirituality into Your Life d Cognitive Health d Work, Home & Leisure Employment Insurance & Financial Information Staying Mobile ...

  4. Quantification of acetaminophen (paracetamol) in human plasma and urine by stable isotope-dilution GC-MS and GC-MS/MS as pentafluorobenzyl ether derivative.

    Science.gov (United States)

    Trettin, Arne; Zoerner, Alexander A; Böhmer, Anke; Gutzki, Frank-Mathias; Stichtenoth, Dirk O; Jordan, Jens; Tsikas, Dimitrios

    2011-08-01

    We report on the quantitative determination of acetaminophen (paracetamol; NAPAP-d(0)) in human plasma and urine by GC-MS and GC-MS/MS in the electron-capture negative-ion chemical ionization (ECNICI) mode after derivatization with pentafluorobenzyl (PFB) bromide (PFB-Br). Commercially available tetradeuterated acetaminophen (NAPAP-d(4)) was used as the internal standard. NAPAP-d(0) and NAPAP-d(4) were extracted from 100-μL aliquots of plasma and urine with 300 μL ethyl acetate (EA) by vortexing (60s). After centrifugation the EA phase was collected, the solvent was removed under a stream of nitrogen gas, and the residue was reconstituted in acetonitrile (MeCN, 100 μL). PFB-Br (10 μL, 30 vol% in MeCN) and N,N-diisopropylethylamine (10 μL) were added and the mixture was incubated for 60 min at 30 °C. Then, solvents and reagents were removed under nitrogen and the residue was taken up with 1000 μL of toluene, from which 1-μL aliquots were injected in the splitless mode. GC-MS quantification was performed by selected-ion monitoring ions due to [M-PFB](-) and [M-PFB-H](-), m/z 150 and m/z 149 for NAPAP-d(0) and m/z 154 and m/z 153 for NAPAP-d(4), respectively. GC-MS/MS quantification was performed by selected-reaction monitoring the transition m/z 150 → m/z 107 and m/z 149 → m/z 134 for NAPAP-d(0) and m/z 154 → m/z 111 and m/z 153 → m/z 138 for NAPAP-d(4). The method was validated for human plasma (range, 0-130 μM NAPAP-d(0)) and urine (range, 0-1300 μM NAPAP-d(0)). Accuracy (recovery, %) ranged between 89 and 119%, and imprecision (RSD, %) was below 19% in these matrices and ranges. A close correlation (r>0.999) was found between the concentrations measured by GC-MS and GC-MS/MS. By this method, acetaminophen can be reliably quantified in small plasma and urine sample volumes (e.g., 10 μL). The analytical performance of the method makes it especially useful in pediatrics. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Solubility of unirradiated UO2 fuel in aqueous solutions. Comparison between experimental and calculated (EQ3/6) data

    International Nuclear Information System (INIS)

    Ollila, K.

    1995-11-01

    The solubility behaviour of unirradiated UO 2 pellets was studied under oxic (air-saturated) and anoxic (N 2 ) conditions in deionized water, in sodium bicarbonate solutions with varying bicarbonate content (60 - 600 ppm), in Allard groundwater simulating granitic fresh groundwater conditions, and in bentonite water simulating the effects of bentonite on granitic fresh groundwater (25 deg C). The release of uranium was measured during static batch dissolution experiments of long duration (2-6 years). A comparison was made with the theoretical solubility data calculated with the geochemical code EQ3/6 in order to evaluate solubility (steady state) limiting factors. (orig.) (26 refs., 32 figs., 13 tabs.)

  6. Questioning the differences between general public vs. patient based preferences towards EQ-5D-5L defined hypothetical health states.

    Science.gov (United States)

    Ogorevc, Marko; Murovec, Nika; Fernandez, Natacha Bolanos; Rupel, Valentina Prevolnik

    2017-03-28

    The purpose of this article is to explore whether any differences exist between the general population and patient based preferences towards EQ-5D-5L defined hypothetical health states. The article discusses the role of adaptation and self-interest in valuing health states and it also contributes rigorous empirical evidence to the scientific debate on the differences between the patient and general population preferences towards hypothetical health states. Patient preferences were elicited in 2015 with the EQ-5D-5L questionnaire using time trade-off and discrete choice experiment design and compared to the Spanish general population preferences, which were elicited using identical methods. Patients were chosen on a voluntary basis according to their willingness to participate in the survey. They were recruited from patient organisations and a hospital in Madrid, Spain. 282 metastatic breast cancer patients and 333 rheumatoid arthritis patients were included in the sample. The analysis revealed differences in preferences between the general population and patient groups. Based on the results of our analysis, it is suggested that the differences in preferences stem from patients being more able to accurately imagine "non-tangible" dimensions of health states (anxiety or depression, and pain or discomfort) than the general population with less experience in various health states. However, this does not mean that general public values should not be reflected in utilities derived for coverage decision making. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Laminite experimental: aspectos morfológicos, morfométricos e ultra-estruturais das lâminas dérmicas e epidérmicas do casco de eqüinos tratados com a trinitroglicerina

    OpenAIRE

    Sampaio, Rita de Cássia de Lima [UNESP

    2007-01-01

    As alterações ultra-estruturais ocorridas nas lâminas epidérmicas e dérmicas de eqüinos com laminite são responsáveis pela rotação ou afundamento da falange distal dentro do casco. Com o objetivo de prevenir esta ocorrência foram estudados os efeitos da sobrecarga de carboidratos (SCHO), assim como da utilização de trinitroglicerina na fase prodrômica da laminite, nas lâminas epidérmicas do casco de quinze eqüinos. A indução da laminite por meio da sobrecarga de carboidratos alterou siginific...

  8. HPLC-UV, MALDI-TOF-MS and ESI-MS/MS analysis of the mechlorethamine DNA crosslink at a cytosine-cytosine mismatch pair.

    Directory of Open Access Journals (Sweden)

    Pornchai Rojsitthisak

    Full Text Available Mechlorethamine [ClCH(2CH(2N(CH(3CH(2CH(2Cl], a nitrogen mustard alkylating agent, has been proven to form a DNA interstrand crosslink at a cytosine-cytosine (C-C mismatch pair using gel electrophoresis. However, the atomic connectivity of this unusual crosslink is unknown.HPLC-UV, MALDI-TOF-MS, and ESI-MS/MS were used to determine the atomic connectivity of the DNA C-C crosslink formed by mechlorethamine, MALDI-TOF-MS of the HPLC-purified reaction product of mechlorethamine with the DNA duplex d[CTCACACCGTGGTTC]•d[GAACCACCGTGTGAG] (underlined bases are a C-C mismatch pair indicated formation of an interstrand crosslink at m/z 9222.088 [M-2H+Na](+. Following enzymatic digestion of the crosslinked duplex by snake venom phosphodiesterase and calf intestinal phosphatase, ESI-MS/MS indicated the presence of dC-mech-dC [mech = CH(2CH(2N(CH(3CH(2CH(2] at m/z 269.2 [M](2+ (expected m/z 269.6, exact mass 539.27 and its hydrolytic product dC-mech-OH at m/z 329.6 [M](+ (expected m/z 329.2. Fragmentation of dC-mech-dC gave product ions at m/z 294.3 and 236.9 [M](+, which are both due to loss of the 4-amino group of cytosine (as ammonia, in addition to dC and dC+HN(CH(3CH = CH(2, respectively. The presence of m/z 269.2 [M](2+ and loss of ammonia exclude crosslink formation at cytosine N(4 or O(2 and indicate crosslinking through cytosine N(3 with formation of two quaternary ammonium ions.Our results provide an important addition to the literature, as the first example of the use of HPLC and MS for analysis of a DNA adduct at the N(3 position of cytosine.

  9. Dynamic changes of flavonoids in Actinidia valvata leaves at different growing stages measured by HPLC-MS/MS.

    Science.gov (United States)

    DU, Qiao-Hui; Zhang, Qiao-Yan; Han, Ting; Jiang, Yi-Ping; Peng, Cheng; Xin, Hai-Liang

    2016-01-01

    Flavonoids are a large group of phenolic secondary metabolites havinga wide range of biochemical and pharmacological effects. Quantitative analysis of flavonoid profiles in the genus Actinidia, which has not been intensively conducted, is useful to a better understanding of the pattern and distribution of flavonoids. In the present work, a liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method was developed to profile the flavonoids, which was then used to determine the dynamic change of 17 biologically active flavonoids in the leaves of Actinidia valvata at the main growing stages, including glucuronides and acylated di- and triglycosides of flavonoids. The contents of flavonoid triglycosides were significantly higher than other flavonoids. The highest concentrations of kaemperol glycosides were observed in June, while other flavonoids showed highest concentrations in October. On the other hand, the contents of four isorhamnetin glycosides were increased sharply in September to October. The flavonoid profiles seem to be related to temperature, UV-B, and water deficit. Further studies are required to examine the functions of flavonoids in the Actinidia valvata and the underlying molecular mechanisms of actions. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  10. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Text Print Discover More Here are a few related topics that may interest you Living with MS (.pdf) Download Brochure Focus on Employment (.pdf) Download Brochure Working with MS (.pdf) Download Brochure Taming Stress (.pdf) Download Brochure Multiple Sclerosis and Your Emotions (. ...

  11. Distinctive and Complementary MS2 Fragmentation Characteristics for Identification of Sulfated Sialylated N-Glycopeptides by nanoLC-MS/MS Workflow

    Science.gov (United States)

    Kuo, Chu-Wei; Guu, Shih-Yun; Khoo, Kay-Hooi

    2018-04-01

    High sensitivity identification of sulfated glycans carried on specific sites of glycoproteins is an important requisite for investigation of molecular recognition events involved in diverse biological processes. However, aiming for resolving site-specific glycosylation of sulfated glycopeptides by direct LC-MS2 sequencing is technically most challenging. Other than the usual limiting factors such as lower abundance and ionization efficiency compared to analysis of non-glycosylated peptides, confident identification of sulfated glycopeptides among the more abundant non-sulfated glycopeptides requires additional considerations in the selective enrichment and detection strategies. Metal oxide has been applied to enrich phosphopeptides and sialylated glycopeptides, but its use to capture sulfated glycopeptides has not been investigated. Likewise, various complementary MS2 fragmentation modes have yet to be tested against sialylated and non-sialylated sulfoglycopeptides due to limited appropriate sample availability. In this study, we have investigated the feasibility of sequencing tryptic sulfated N-glycopeptide and its MS2 fragmentation characteristics by first optimizing the enrichment methods to allow efficient LC-MS detection and MS2 analysis by a combination of CID, HCD, ETD, and EThcD on hybrid and tribrid Orbitrap instruments. Characteristic sulfated glyco-oxonium ions and direct loss of sulfite from precursors were detected as evidences of sulfate modification. It is anticipated that the technical advances demonstrated in this study would allow a feasible extension of our sulfoglycomic analysis to sulfoglycoproteomics. [Figure not available: see fulltext.

  12. How much separation for LC-MS/MS quantitative bioanalysis of drugs and metabolites?

    Science.gov (United States)

    Tan, Aimin; Fanaras, John C

    2018-05-01

    LC-MS/MS has been the dominant analytical technology for quantitative bioanalysis of drugs and metabolites for more than two decades. Despite this, a very fundamental question like how much separation is required for LC-MS/MS quantitative bioanalysis of drugs and metabolites has not been adequately addressed. Some think that no or only very limited separation is necessary thanks to the unparalleled selectivity offered by tandem mass spectrometry. Others think that the more separation, the better, because of the potential detrimental impact of matrix effect (ion suppression or enhancement). Still others just use a rule-of-thumb approach by keeping the adjusted retention/capacity factor always between 2 and 5. The purpose of this article is to address this fundamental question through rational thinking together with various real case examples drawn from regulated bioanalytical laboratories. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Pediatric siMS score: A new, simple and accurate continuous metabolic syndrome score for everyday use in pediatrics.

    Science.gov (United States)

    Vukovic, Rade; Milenkovic, Tatjana; Stojan, George; Vukovic, Ana; Mitrovic, Katarina; Todorovic, Sladjana; Soldatovic, Ivan

    2017-01-01

    The dichotomous nature of the current definition of metabolic syndrome (MS) in youth results in loss of information. On the other hand, the calculation of continuous MS scores using standardized residuals in linear regression (Z scores) or factor scores of principal component analysis (PCA) is highly impractical for clinical use. Recently, a novel, easily calculated continuous MS score called siMS score was developed based on the IDF MS criteria for the adult population. To develop a Pediatric siMS score (PsiMS), a modified continuous MS score for use in the obese youth, based on the original siMS score, while keeping the score as simple as possible and retaining high correlation with more complex scores. The database consisted of clinical data on 153 obese (BMI ≥95th percentile) children and adolescents. Continuous MS scores were calculated using Z scores and PCA, as well as the original siMS score. Four variants of PsiMS score were developed in accordance with IDF criteria for MS in youth and correlation of these scores with PCA and Z score derived MS continuous scores was assessed. PsiMS score calculated using formula: (2xWaist/Height) + (Glucose(mmol/l)/5.6) + (triglycerides(mmol/l)/1.7) + (Systolic BP/130)-(HDL(mmol/l)/1.02) showed the highest correlation with most of the complex continuous scores (0.792-0.901). The original siMS score also showed high correlation with continuous MS scores. PsiMS score represents a practical and accurate score for the evaluation of MS in the obese youth. The original siMS score should be used when evaluating large cohorts consisting of both adults and children.

  14. Acoustic Sample Deposition MALDI-MS (ASD-MALDI-MS): A Novel Process Flow for Quality Control Screening of Compound Libraries.

    Science.gov (United States)

    Chin, Jefferson; Wood, Elizabeth; Peters, Grace S; Drexler, Dieter M

    2016-02-01

    In the early stages of drug discovery, high-throughput screening (HTS) of compound libraries against pharmaceutical targets is a common method to identify potential lead molecules. For these HTS campaigns to be efficient and successful, continuous quality control of the compound collection is necessary and crucial. However, the large number of compound samples and the limited sample amount pose unique challenges. Presented here is a proof-of-concept study for a novel process flow for the quality control screening of small-molecule compound libraries that consumes only minimal amounts of samples and affords compound-specific molecular data. This process employs an acoustic sample deposition (ASD) technique for the offline sample preparation by depositing nanoliter volumes in an array format onto microscope glass slides followed by matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analysis. An initial study of a 384-compound array employing the ASD-MALDI-MS workflow resulted in a 75% first-pass positive identification rate with an analysis time of <1 s per sample. © 2015 Society for Laboratory Automation and Screening.

  15. pyOpenMS: a Python-based interface to the OpenMS mass-spectrometry algorithm library.

    Science.gov (United States)

    Röst, Hannes L; Schmitt, Uwe; Aebersold, Ruedi; Malmström, Lars

    2014-01-01

    pyOpenMS is an open-source, Python-based interface to the C++ OpenMS library, providing facile access to a feature-rich, open-source algorithm library for MS-based proteomics analysis. It contains Python bindings that allow raw access to the data structures and algorithms implemented in OpenMS, specifically those for file access (mzXML, mzML, TraML, mzIdentML among others), basic signal processing (smoothing, filtering, de-isotoping, and peak-picking) and complex data analysis (including label-free, SILAC, iTRAQ, and SWATH analysis tools). pyOpenMS thus allows fast prototyping and efficient workflow development in a fully interactive manner (using the interactive Python interpreter) and is also ideally suited for researchers not proficient in C++. In addition, our code to wrap a complex C++ library is completely open-source, allowing other projects to create similar bindings with ease. The pyOpenMS framework is freely available at https://pypi.python.org/pypi/pyopenms while the autowrap tool to create Cython code automatically is available at https://pypi.python.org/pypi/autowrap (both released under the 3-clause BSD licence). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. The neurophysiologist perspective into MS plasticity

    Directory of Open Access Journals (Sweden)

    Elise eHoudayer

    2015-09-01

    Full Text Available Multiple sclerosis (MS is a frequent, highly debilitating inflammatory demyelinating disease, starting to manifest in early adulthood and presenting a wide variety of symptoms which are often resistant to pharmacological treatments. Cortical dysfunctions have been demonstrated to be key components of MS condition, and plasticity of the corticospinal motor system is highly involved in major MS symptoms, such as fatigue, spasticity or pain. Cortical dysfunction in MS can be studied with neurophysiological tools such as electroencephalography (EEG and related techniques (evoked potentials – EPs or transcranial magnetic stimulation (TMS. These techniques are now widely used to provide essential elements of MS diagnosis and can also be used to modulate plasticity. Indeed the recent development of non-invasive brain stimulation (NIBS techniques able to induce cortical plasticity, such as repetitive TMS or transcranial direct current stimulation (tDCS, has brought promising results as add-on treatments.In this review we will focus on the use of these tools (EEG, TMS to study plasticity in MS and on the major techniques used to modulate plasticity in MS.

  17. The Neurophysiologist Perspective into MS Plasticity.

    Science.gov (United States)

    Houdayer, Elise; Comi, Giancarlo; Leocani, Letizia

    2015-01-01

    Multiple sclerosis (MS) is a frequent, highly debilitating inflammatory demyelinating disease, starting to manifest in early adulthood and presenting a wide variety of symptoms, which are often resistant to pharmacological treatments. Cortical dysfunctions have been demonstrated to be key components of MS condition, and plasticity of the corticospinal motor system is highly involved in major MS symptoms, such as fatigue, spasticity, or pain. Cortical dysfunction in MS can be studied with neurophysiological tools, such as electroencephalography (EEG) and related techniques (evoked potentials) or transcranial magnetic stimulation (TMS). These techniques are now widely used to provide essential elements of MS diagnosis and can also be used to modulate plasticity. Indeed, the recent development of non-invasive brain stimulation techniques able to induce cortical plasticity, such as repetitive TMS or transcranial direct current stimulation, has brought promising results as add-on treatments. In this review, we will focus on the use of these tools (EEG and TMS) to study plasticity in MS and on the major techniques used to modulate plasticity in MS.

  18. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  19. The development and validation of an UHPLC-MS/MS method for the rapid quantification of the antiretroviral agent dapivirine in human plasma.

    Science.gov (United States)

    Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A

    2013-11-01

    Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. A robust and sensitive LC-MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials.

  20. Chemical characterization of Azadirachta indica grafted on Melia azedarach and analyses of azadirachtin by HPLC-MS-MS (SRM) and meliatoxins by MALDI-MS.

    Science.gov (United States)

    Forim, Moacir Rossi; Cornélio, Vivian Estevam; da Silva, M Fátima das G F; Rodrigues-Filho, Edson; Fernandes, João B; Vieira, Paulo C; Matinez, Sueli Souza; Napolitano, Michael P; Yost, Richard A

    2010-01-01

    Melia azedarach adapted to cool climates was selected as rootstocks for vegetative propagation of Azadirachta indica. Cleft grafting of A. indica on M. azedarach rootstock showed excellent survival. Little is known about the chemistry of grafting. The roots, stems, leaves and seeds of this graft were examined in order to verify if grafted A. indica would produce limonoids different from those found in non-grafted plants. Intact matured fruits were also studied to verify if they were free of meliatoxins. After successive chromatographic separations the extracts afforded several limonoids. HPLC-MS/MS and MALDI-MS were used to develop sensitive methods for detecting azadirachtin on all aerial parts of this graft and meliatoxins in fruits, respectively. The stem afforded the limonoid salannin, which was previously found in the oil seeds of A. indica. Salannin is also found in the root bark of M. azedarach. Thus, the finding of salannin in this study suggests that it could have been translocated from the M. azedarach rootstock to the A. indica graft. HPLC-MS/MS analyses showed that azadirachtin was present in all parts of the fruits, stem, flowers and root, but absent in the leaves. The results of MALDI-MS analyses confirmed the absence of meliatoxins in graft fruits. This study showed that A. indica grafted onto M. azedarach rootstock produces azadirachtin, and also that its fruits are free of meliatoxins from rootstocks, confirming that this graft forms an excellent basis for breeding vigorous Neem trees in cooler regions.

  1. The utility of ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) for clinically relevant steroid analysis.

    Science.gov (United States)

    Storbeck, Karl-Heinz; Gilligan, Lorna; Jenkinson, Carl; Baranowski, Elizabeth S; Quanson, Jonathan L; Arlt, Wiebke; Taylor, Angela E

    2018-05-15

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) assays are considered the reference standard for serum steroid hormone analyses, while full urinary steroid profiles are only achievable by gas chromatography (GC-MS). Both LC-MS/MS and GC-MS have well documented strengths and limitations. Recently, commercial ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) systems have been developed. These systems combine the resolution of GC with the high-throughput capabilities of UHPLC. Uptake of this new technology into research and clinical labs has been slow, possibly due to the perceived increase in complexity. Here we therefore present fundamental principles of UHPSFC-MS/MS and the likely applications for this technology in the clinical research setting, while commenting on potential hurdles based on our experience to date. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Simultaneous Determination of Cyclosporine A, Tacrolimus, Sirolimus, and Everolimus in Whole-Blood Samples by LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Mustafa Karapirli

    2012-01-01

    Full Text Available Objectives. Cyclosporine A (CyA, tacrolimus (TRL, sirolimus (SIR, and everolimus (RAD are immunosuppressive drugs frequently used in organ transplantation. Our aim was to confirm a robust sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS method for determination of CyA, TRL, SIR, and RAD in whole-blood samples. Materials and Methods. We used an integrated online solid-phase extraction-LC-MS/MS system and atmospheric pressure ionization tandem mass spectrometry (API-MS/MS in the multiple reaction monitoring (MRM detection mode. CyA, TRL, SIR, and RAD were simultaneously analyzed in whole blood treated with precipitation reagent taken from transplant patients. Results. System performance parameters were suitable for using this method as a high-throughput technique in clinical practice. The high concentration of one analyte in the sample did not affect the concentration of other analytes. Total analytical time was 2.5 min, and retention times of all analytes were shorter than 2 minutes. Conclusion. This LC-MS/MS method can be preferable for therapeutic drug monitoring of these immunosuppressive drugs (CyA, TRL, SRL, and RAD in whole blood. Sample preparation was too short and simple in this method, and it permits robust, rapid, sensitive, selective, and simultaneous determination of these drugs.

  3. A UPLC-MS/MS method for analysis of vancomycin in human cerebrospinal fluid and comparison with the chemiluminescence immunoassay.

    Science.gov (United States)

    Mei, Shenghui; Wang, Jiaqing; Zhu, Leting; Chen, Ruiling; Li, Xingang; Chen, Kai; Chen, Guangqiang; Zhou, Jianxin; Wang, Qiang; Zhao, Zhigang

    2017-08-01

    Vancomycin (VCM) is clinically used in treating patients with postoperative intracranial infections. The cerebrospinal fluid (CSF) concentration of VCM varies greatly among patients. To guide the dosage regimens, monitoring of VCM in CSF is needed. However a method for analysis of VCM in human CSF is lacking. An ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for analysis of VCM in human CSF, and the agreement of UPLC-MS/MS and chemiluminescence immunoassay (CLIA) in the analysis of CSF VCM was evaluated. The ion transitions were m/z 725.5 > 144.1 for VCM and m/z 455.2 > 308.2 for methotrexate (internal standard). The agreement between UPLC-MS/MS and CLIA was evaluated by Bland-Altman plot in 179 samples. The calibration range of the UPLC-MS/MS method was 1-400 mg/L. The inaccuracy and imprecision were -0.69-10.80% and  0.98). The 95% limit of agreement of the ratio of CLIA to UPLC-MS/MS was 61.66-107.40%. Further studies are warranted to confirm the results. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Development and validation of analytical method for Naftopidil in human plasma by LC–MS/MS

    Directory of Open Access Journals (Sweden)

    Pritam S. Jain

    2015-09-01

    Full Text Available A highly sensitive and simple high-performance liquid chromatographic–tandem mass spectrometric (LC–MS-MS assay is developed and validated for the quantification of Naftopidil in human plasma. Naftopidil is extracted from human plasma by methyl tertiary butyl ether and analyzed using a reversed-phase gradient elution on a discovery C 18 5 μ (50 × 4.6 column. A methanol: 2 mM ammonium formate (90:10 as mobile phase, is used and detection was performed by MS using electrospray ionization in positive mode. Propranolol is used as the internal standard. The lower limits of quantification are 0.495 ng/mL. The calibration curves are linear over the concentration range of 0.495–200.577 ng/mL of plasma for each analyte. This novel LC–MS-MS method shows satisfactory accuracy and precision and is sufficiently sensitive for the performance of pharmacokinetic studies in humans.

  5. Determination of chlormequat in pig serum and sow milk by LC-MS/MS

    DEFF Research Database (Denmark)

    Poulsen, Mette Erecius; Christensen, Hanne Bjerre; Sørensen, M.T.

    2007-01-01

    reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80...

  6. Metabolomics data normalization with EigenMS.

    Directory of Open Access Journals (Sweden)

    Yuliya V Karpievitch

    Full Text Available Liquid chromatography mass spectrometry has become one of the analytical platforms of choice for metabolomics studies. However, LC-MS metabolomics data can suffer from the effects of various systematic biases. These include batch effects, day-to-day variations in instrument performance, signal intensity loss due to time-dependent effects of the LC column performance, accumulation of contaminants in the MS ion source and MS sensitivity among others. In this study we aimed to test a singular value decomposition-based method, called EigenMS, for normalization of metabolomics data. We analyzed a clinical human dataset where LC-MS serum metabolomics data and physiological measurements were collected from thirty nine healthy subjects and forty with type 2 diabetes and applied EigenMS to detect and correct for any systematic bias. EigenMS works in several stages. First, EigenMS preserves the treatment group differences in the metabolomics data by estimating treatment effects with an ANOVA model (multiple fixed effects can be estimated. Singular value decomposition of the residuals matrix is then used to determine bias trends in the data. The number of bias trends is then estimated via a permutation test and the effects of the bias trends are eliminated. EigenMS removed bias of unknown complexity from the LC-MS metabolomics data, allowing for increased sensitivity in differential analysis. Moreover, normalized samples better correlated with both other normalized samples and corresponding physiological data, such as blood glucose level, glycated haemoglobin, exercise central augmentation pressure normalized to heart rate of 75, and total cholesterol. We were able to report 2578 discriminatory metabolite peaks in the normalized data (p<0.05 as compared to only 1840 metabolite signals in the raw data. Our results support the use of singular value decomposition-based normalization for metabolomics data.

  7. Analysis of benzodiazepines and their metabolites using DBS cards and LC-MS/MS.

    Science.gov (United States)

    Lee, Heesang; Park, Yujin; Jo, Jiyeong; In, Sangwhan; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Choe, Sanggil

    2015-10-01

    Dried Blood Spot (DBS) has been used a blood extraction method for inherited metabolic disorder screening since 1960s. With introduction of LC-MS/MS, not only DBS could be used to analysis drugs in small blood volume, but in various fields, such as toxicology, drug therapeutic monitoring, drug diagnostic screening, and illicit drugs. In toxicology field, many drugs (e.g. benzodiazepines, acetaminophen, small molecule drugs) have been tested with DBS. Compared with earlier blood extraction methods (SPE and LLE), DBS has lots of advantages; lower blood volume (less than 50μL), shorter analysis time caused by a more concise analysis procedure and lower cost. We optimized the DBS procedure and LC-MS/MS conditions for 18 benzodiazepines, seven benzodiazepine metabolites, and one z-drug (zolpidem) analysis in blood. 30μL of whole blood was spotted on FTA DMPK card C and dried for 2h in a desiccator. A 6-mm disk was punched and vortexed for 1min in a centrifuge tube with 300μL methanol/acetonitrile mixture (1:1, v/v). After evaporation, redissolved in 100μL mobile phase of LC-MS/MS and 5μL was injected. In the analysis for 26 target compounds in blood, all of the method validation parameters - LLOD, LLOQ, accuracy (intra- and inter-assay), and precision (intra- and inter-assay) - were satisfied with method validation criteria, within 15%. The results of matrix effect, recovery, and process efficiency were good. We developed a fast and reliable sample preparation method using DBS for 26 benzodiazepines, benzodiazepine metabolites, and z-drug (zolpidem). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Ativação de plaquetas de eqüinos com laminite induzida e tratados com ketoprofeno, fenilbutazona e flunixin meglumina Platelets activation in equine with induced laminitis and treated with ketoprophen, phenylbutazone and flunixin meglumin

    Directory of Open Access Journals (Sweden)

    F.O. Paes Leme

    2006-04-01

    Full Text Available Avaliou-se a ativação de plaquetas em 20 eqüinos com laminite induzida, tratados com ketoprofeno, fenilbutazona e flunixin meglumina. As alterações de plaquetas incluíram mudança de forma, alteração da relação entre os eixos maior e menor, aumento de perímetro, emissão de pseudópodes, aumento no número dealfa-grânulos e de grânulos de glicogênio e redução no número degama-grânulos. As plaquetas de eqüinos, quando ativadas, apresentaram perfil de organela diferente de plaquetas normais, e as drogas antiinflamatórias, não-esteroidais, demonstraram atividade na ativação plaquetária de eqüinos in vivo. O flunixin meglumina apresentou melhor atividade em modular a ativação plaquetária de eqüinos in vivo do que a fenilbutazona e o ketoprofeno.The platelets activation from 20 equines submitted to laminitis induction and treated with ketoprophen, phenylbutazone and flunixin meglumin, was evaluated. The platelets changes included shape change, altered relations between axis, increased perimeter, pseudopodia, increased alpha-granules and glycogen-granules, and decreased in gamma-granules. Platelets when activated present a different organelle profile than normal ones. Equine activated platelets had different organelles profile than normal ones, and anti-inflammatory drugs can modulate the platelet activation, being the flunixin meglumin better than phenylbutazone and ketoprophen.

  9. Estimativa da digestibilidade aparente de nutrientes em dietas para eqüinos, com o uso de óxido crômico e indicadores internos

    Directory of Open Access Journals (Sweden)

    Oliveira Chiara Albano de Araújo

    2003-01-01

    Full Text Available Foram realizados dois ensaios com o objetivo de avaliar a digestibilidade aparente de nutrientes em dietas para eqüinos, utilizando o método da coleta total de fezes e os indicadores óxido crômico, fibra em detergente ácido indigestível (FDAi, fibra em detergente neutro indigestível (FDNi, celulose indigestível (CELi, lignina (LIG e cinzas insolúveis em detergente ácido (CIDA. No primeiro ensaio, foram utilizados cinco potros mestiços, alimentados com cinco dietas contendo níveis diferenciados de proteína bruta, mantendo a relação concentrado e volumoso em 50:50. O óxido crômico foi utilizado como indicador externo. No segundo ensaio, foram utilizados quatro potros mestiços, alimentados com dietas compostas por feno de coastcross como volumoso e concentrado nas proporções de 40:60, 60:40, 80:20 e 100:00. Nos dois ensaios, os teores de fibra em detergente ácido indigestível, fibra em detergente neutro indigestível, celulose indigestível, lignina e cinzas insolúveis em detergente ácido foram obtidos após incubação in vitro. No primeiro ensaio, a FDAi mostrou-se adequada como indicador interno para estimar a digestibilidade; a CELi, em ambos os ensaios, foi adequada como indicador interno para a estimativa da digestibilidade aparente de nutrientes em dietas para eqüinos. O óxido crômico apresentou baixa recuperação fecal no primeiro ensaio e a LIG, baixa recuperação fecal nos dois ensaios, subestimando os coeficientes de digestibilidade dos nutrientes, sendo inadequada sua utilização para estimativa da digestibilidade. A CIDA, em função da metodologia de coleta fecal, também mostrou-se inadequada para as estimativas de digestibilidade em eqüinos.

  10. HDX Workbench: Software for the Analysis of H/D Exchange MS Data

    Science.gov (United States)

    Pascal, Bruce D.; Willis, Scooter; Lauer, Janelle L.; Landgraf, Rachelle R.; West, Graham M.; Marciano, David; Novick, Scott; Goswami, Devrishi; Chalmers, Michael J.; Griffin, Patrick R.

    2012-09-01

    Hydrogen/deuterium exchange mass spectrometry (HDX-MS) is an established method for the interrogation of protein conformation and dynamics. While the data analysis challenge of HDX-MS has been addressed by a number of software packages, new computational tools are needed to keep pace with the improved methods and throughput of this technique. To address these needs, we report an integrated desktop program titled HDX Workbench, which facilitates automation, management, visualization, and statistical cross-comparison of large HDX data sets. Using the software, validated data analysis can be achieved at the rate of generation. The application is available at the project home page http://hdx.florida.scripps.edu.

  11. Data-independent MS/MS quantification of neuropeptides for determination of putative feeding-related neurohormones in microdialysate.

    Science.gov (United States)

    Schmerberg, Claire M; Liang, Zhidan; Li, Lingjun

    2015-01-21

    Food consumption is an important behavior that is regulated by an intricate array of neuropeptides (NPs). Although many feeding-related NPs have been identified in mammals, precise mechanisms are unclear and difficult to study in mammals, as current methods are not highly multiplexed and require extensive a priori knowledge about analytes. New advances in data-independent acquisition (DIA) MS/MS and the open-source quantification software Skyline have opened up the possibility to identify hundreds of compounds and quantify them from a single DIA MS/MS run. An untargeted DIA MS(E) quantification method using Skyline software for multiplexed, discovery-driven quantification was developed and found to produce linear calibration curves for peptides at physiologically relevant concentrations using a protein digest as internal standard. By using this method, preliminary relative quantification of the crab Cancer borealis neuropeptidome (winnowing candidate NPs related to a behavior of interest in a functionally relevant manner, and demonstrates the success of such a UPLC-MS(E) quantification method using the open source software Skyline.

  12. Identification of alkyl dimethylbenzylammonium surfactants in water samples by solid-phase extraction followed by ion trap LC/MS and LC/MS/MS

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2001-01-01

    A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry(MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BAC - ranging from 1.2 to 36.6 micrograms per liter - were found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.

  13. Estimation of net greenhouse gas balance using crop- and soil-based approaches: Two case studies

    International Nuclear Information System (INIS)

    Huang, Jianxiong; Chen, Yuanquan; Sui, Peng; Gao, Wansheng

    2013-01-01

    The net greenhouse gas balance (NGHGB), estimated by combining direct and indirect greenhouse gas (GHG) emissions, can reveal whether an agricultural system is a sink or source of GHGs. Currently, two types of methods, referred to here as crop-based and soil-based approaches, are widely used to estimate the NGHGB of agricultural systems on annual and seasonal crop timescales. However, the two approaches may produce contradictory results, and few studies have tested which approach is more reliable. In this study, we examined the two approaches using experimental data from an intercropping trial with straw removal and a tillage trial with straw return. The results of the two approaches provided different views of the two trials. In the intercropping trial, NGHGB estimated by the crop-based approach indicated that monocultured maize (M) was a source of GHGs (− 1315 kg CO 2 −eq ha −1 ), whereas maize–soybean intercropping (MS) was a sink (107 kg CO 2 −eq ha −1 ). When estimated by the soil-based approach, both cropping systems were sources (− 3410 for M and − 2638 kg CO 2 −eq ha −1 for MS). In the tillage trial, mouldboard ploughing (MP) and rotary tillage (RT) mitigated GHG emissions by 22,451 and 21,500 kg CO 2 −eq ha −1 , respectively, as estimated by the crop-based approach. However, by the soil-based approach, both tillage methods were sources of GHGs: − 3533 for MP and − 2241 kg CO 2 −eq ha −1 for RT. The crop-based approach calculates a GHG sink on the basis of the returned crop biomass (and other organic matter input) and estimates considerably more GHG mitigation potential than that calculated from the variations in soil organic carbon storage by the soil-based approach. These results indicate that the crop-based approach estimates higher GHG mitigation benefits compared to the soil-based approach and may overestimate the potential of GHG mitigation in agricultural systems. - Highlights: • Net greenhouse gas balance (NGHGB) of

  14. Improved liquid chromatography-MS/MS of heparan sulfate oligosaccharides via chip-based pulsed makeup flow.

    Science.gov (United States)

    Huang, Yu; Shi, Xiaofeng; Yu, Xiang; Leymarie, Nancy; Staples, Gregory O; Yin, Hongfeng; Killeen, Kevin; Zaia, Joseph

    2011-11-01

    Microfluidic chip-based hydrophilic interaction chromatography (HILIC) is a useful separation system for liquid chromatography-mass spectrometry (LC-MS) in compositional profiling of heparan sulfate (HS) oligosaccharides; however, ions observed using HILIC LC-MS are low in charge. Tandem MS of HS oligosaccharide ions with low charge results in undesirable losses of SO(3) from precursor ions during collision induced dissociation. One solution is to add metal cations to stabilize sulfate groups. Another is to add a nonvolatile, polar compound such as sulfolane, a molecule known to supercharge proteins, to produce a similar effect for oligosaccharides. We demonstrate use of a novel pulsed makeup flow (MUF) HPLC-chip. The chip enables controlled application of additives during specified chromatographic time windows and thus minimizes the extent to which nonvolatile additives build up in the ion source. The pulsed MUF system was applied to LC-MS/MS of HS oligosaccharides. Metal cations and sulfolane were tested as additives. The most promising results were obtained for sulfolane, for which supercharging of the oligosaccharide ions increased their signal strengths relative to controls. Tandem MS of these supercharged precursor ions showed decreased abundances of product ions from sulfate losses yet more abundant product ions from backbone cleavages.

  15. Determination of Dextromethorphan in Oral Fluid by LC-MS-MS.

    Science.gov (United States)

    Amaratunga, Piyadarsha; Clothier, Morgan; Lorenz Lemberg, Bridget; Lemberg, Dave

    2016-06-01

    Dextromethorphan (DXM) is an antitussive drug found in commonly used nonprescription cold and cough medications. At low doses, DXM is a safe drug that does not produce adverse reactions. However, abuse of DXM has been reported among adolescents and young adults using the drug at higher doses. DXM is not a scheduled drug in the USA, and the primary reason for its abuse is the ease of availability. DXM is available to purchase in the form of over-the-counter cough medications, such as Robitussin(®) and Coricidin(®), or it can be purchased over the Internet in the form of a powder. In this research work, we developed an LC-MS-MS method that can quantify DXM and dextrorphan (DXO) in oral fluid in a high-throughput toxicology laboratory setting. The developed method was validated according to the Scientific Working Group for Forensic Toxicology guidelines. The linear dynamic range was 5-100 ng/mL with a lowest limit of quantitation (LLOQ) of 5.0 ng/mL for DXM and DXO. Overall, the results of the accuracy and the precision values were within the acceptance criteria for both drugs. In addition, selectivity, matrix effect and recovery were calculated for the LC-MS-MS method. Authentic samples (n = 59) were tested to evaluate the applicability of the method. Thirty samples were found to be positive for DXM and DXO and two samples were found to be positive for DXM only. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Contribuição ao estudo do funículo espermático em eqüinos sem raça definida (Equus caballus, L.

    Directory of Open Access Journals (Sweden)

    André Luiz Quagliatto Santos

    1992-06-01

    Full Text Available Utilizando 35 pares de funículos esperméticos de eqüinos sem raça definida, estudaram-se os aspectos histológicos dos envoltórios funiculares, dos vasos arteriais e venosos e dos tecidos intervasculares, assim como o seu arranjo vascular e o comprimento do segmento da artéria testicular nele contido.

  17. Adult Empathy: Possible Gender Differences in Gene-Environment Architecture for Cognitive and Emotional Components in a Large Italian Twin Sample.

    Science.gov (United States)

    Toccaceli, Virgilia; Fagnani, Corrado; Eisenberg, Nancy; Alessandri, Guido; Vitale, Augusto; Stazi, Maria Antonietta

    2018-04-15

    Empathy plays a central role in prosocial behavior and human cooperation. Very few twin researchers have investigated innate and environmental effects in adult empathy, and twin research on gender differences in these effects is sparse. The goal of this study was to examine innate and environmental influences on three components of an empathy scale frequently used with adults - the expression of cognitive (CE), emotional (EE), and social skills (SS) empathy - and to explore gender differences in the influences. Study participants were ~1,700 twins (18-65 years) enrolled in the Italian Twin Registry. Empathy was assessed with the Italian version of the Empathy Quotient (EQ), for which the three-factor structure (i.e., CE, EE, and SS) was confirmed. Twin correlations in monozygotic and dizygotic pairs, and males and females were estimated for the total EQ and subscale scores, and univariate genetic model fitting was carried out. Women's empathy (i.e., total EQ as well as CE and EE subdimensions) was predominantly driven by genetic factors and individual experiences, whereas for males, no genetic contribution or important shared and individual environmental effects emerged. Although of large magnitude, the gender differences did not reach statistical significance. Age did not moderate empathy heritability in adulthood. Only for the SS subscale were genetic and environmental proportions of variance similar for men and women. This study suggests possible gender-specific innate and environmental influences on empathy and its cognitive and emotional components that need to be confirmed in future studies.

  18. Analysis of banned veterinary drugs and herbicide residues in shellfish by liquid chromatography-tandem mass spectrometry (LC/MS/MS) and gas chromatography-tandem mass spectrometry (GC/MS/MS)

    International Nuclear Information System (INIS)

    Chang, Geng-Ruei; Chen, Hui-Shan; Lin, Feng-Yi

    2016-01-01

    Seafood safety is a crucial public health concern for consumers. In this study, we applied a validated method to analyze the residue of banned veterinary drugs in shellfish, namely chloramphenicol, malachite green, leucomalachite green, and nitrofuran metabolites; additionally, the QuEChERS method was employed to detect 76 herbicides by LC/MS/MS and GC/MS/MS. In total, 42 shellfish samples, which included hard clams, freshwater clams, and oysters, were collected from aquafarms and production areas in Taiwan during 2012. Our results revealed 3.8 ng/g of chloramphenicol in one hard clam, 19.9–32.1 ng/g of ametryn in two hard clams, 16.1–60.1 ng/g of pendimethalin in four hard clams, and 17.0 ng/g of mefenacet in one oyster, indicating that 19.1% of the samples contained residues from banned veterinary drugs and pesticides. These data can be used to monitor the residue of veterinary drugs and pesticides in aquatic organisms and as a reference for food safety. - Highlights: • A certified method was employed for analyzing residues of banned veterinary drugs and herbicides in shellfish samples. • The trace levels of chloramphenicol, ametryn, pendimethalin were detected in hard clam samples. • For ensuring food safety, continual monitoring of aquatic products is necessary.

  19. Structural Feature Ions for Distinguishing N- and O-Linked Glycan Isomers by LC-ESI-IT MS/MS

    Science.gov (United States)

    Everest-Dass, Arun V.; Abrahams, Jodie L.; Kolarich, Daniel; Packer, Nicolle H.; Campbell, Matthew P.

    2013-06-01

    Glycomics is the comprehensive study of glycan expression in an organism, cell, or tissue that relies on effective analytical technologies to understand glycan structure-function relationships. Owing to the macro- and micro-heterogeneity of oligosaccharides, detailed structure characterization has required an orthogonal approach, such as a combination of specific exoglycosidase digestions, LC-MS/MS, and the development of bioinformatic resources to comprehensively profile a complex biological sample. Liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) has emerged as a key tool in the structural analysis of oligosaccharides because of its high sensitivity, resolution, and robustness. Here, we present a strategy that uses LC-ESI-MS/MS to characterize over 200 N- and O-glycans from human saliva glycoproteins, complemented by sequential exoglycosidase treatment, to further verify the annotated glycan structures. Fragment-specific substructure diagnostic ions were collated from an extensive screen of the literature available on the detailed structural characterization of oligosaccharides and, together with other specific glycan structure feature ions derived from cross-ring and glycosidic-linkage fragmentation, were used to characterize the glycans and differentiate isomers. The availability of such annotated mass spectrometric fragmentation spectral libraries of glycan structures, together with such substructure diagnostic ions, will be key inputs for the future development of the automated elucidation of oligosaccharide structures from MS/MS data.

  20. Application of HRAM screening and LC-MS/MS confirmation of active pharmaceutical ingredient in "natural" herbal supplements.

    Science.gov (United States)

    Pascali, Jennifer P; Fais, Paolo; Vaiano, Fabio; Bertol, Elisabetta

    2018-05-01

    The growing market of herbal remedies worldwide could pose severe problems to consumers' health due to the possible presence of potentially harmful, undeclared synthetic substances or analogues of prescription drugs. The present work shows a simple but effective approach to unequivocally identify synthetic anorectic compounds in allegedly 'natural' herbal extracts, by exploiting liquid chromatography/time of flight (Q-TOF LC/MS) technology coupled to liquid chromatography/triple quadrupole (LC-MS/MS) confirmation and quantitation. The procedure was applied to five tea herbal extracts and pills sold as coadjutant for weigh loss. The method exploited liquid-liquid sample extraction (LLE) and separation in a C18 (2.1mm×150mm, 1.8μm) column. QTOF acquisitions were carried out both in scan mode and all ion MS/MS mode and results were obtained after search against ad hoc prepared library. Sibutramine, 4-hydroxyamphetamine, caffeine and theophylline were preliminary identified samples. Confirmation and quantitation of the preliminary identified compounds were obtained in LC-MS/MS after preparation of appropriated standards. Sibutramine, caffeine and theophylline were finally confirmed and quantitate. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Post-acquisition data mining techniques for LC-MS/MS-acquired data in drug metabolite identification.

    Science.gov (United States)

    Dhurjad, Pooja Sukhdev; Marothu, Vamsi Krishna; Rathod, Rajeshwari

    2017-08-01

    Metabolite identification is a crucial part of the drug discovery process. LC-MS/MS-based metabolite identification has gained widespread use, but the data acquired by the LC-MS/MS instrument is complex, and thus the interpretation of data becomes troublesome. Fortunately, advancements in data mining techniques have simplified the process of data interpretation with improved mass accuracy and provide a potentially selective, sensitive, accurate and comprehensive way for metabolite identification. In this review, we have discussed the targeted (extracted ion chromatogram, mass defect filter, product ion filter, neutral loss filter and isotope pattern filter) and untargeted (control sample comparison, background subtraction and metabolomic approaches) post-acquisition data mining techniques, which facilitate the drug metabolite identification. We have also discussed the importance of integrated data mining strategy.

  2. Evaluation of a multiresidue method for measuring fourteen chemical groups of pesticides in water by use of LC-MS-MS.

    Science.gov (United States)

    Carvalho, J J; Jerónimo, P C A; Gonçalves, C; Alpendurada, M F

    2008-11-01

    European Council Directive 98/83/EC on the quality of water intended for human consumption brought a new challenge for water-quality control routine laboratories, mainly on pesticides analysis. Under the guidelines of ISO/IEC 17025:2005, a multiresidue method was developed, validated, implemented in routine, and studied with real samples during a one-year period. The proposed method enables routine laboratories to handle a large number of samples, since 28 pesticides of 14 different chemical groups can be quantitated in a single procedure. The method comprises a solid-phase extraction step and subsequent analysis by liquid chromatography-mass spectrometry (LC-MS-MS). The accuracy was established on the basis of participation in interlaboratory proficiency tests, with encouraging results (majority |z-score| <2), and the precision was consistently analysed over one year. The limits of quantitation (below 0.050 microg L(-1)) are in agreement with the enforced threshold value for pesticides of 0.10 microg L(-1). Overall method performance is suitable for routine use according to accreditation rules, taking into account the data collected over one year.

  3. Sensitivity and proportionality assessment of metabolites from microdose to high dose in rats using LC-MS/MS.

    Science.gov (United States)

    Ni, Jinsong; Ouyang, Hui; Seto, Carmai; Sakuma, Takeo; Ellis, Robert; Rowe, Josh; Acheampong, Andrew; Welty, Devin; Szekely-Klepser, Gabriella

    2010-03-01

    The objective of this study was to evaluate the sensitivity requirement for LC-MS/MS as an analytical tool to characterize metabolites in plasma and urine at microdoses in rats and to investigate proportionality of metabolite exposure from a microdose of 1.67 µg/kg to a high dose of 5000 µg/kg for atorvastatin, ofloxacin, omeprazole and tamoxifen. Only the glucuronide metabolite of ofloxacin, the hydroxylation metabolite of omeprazole and the hydration metabolite of tamoxifen were characterized in rat plasma at microdose by LC-MS/MS. The exposure of detected metabolites of omeprazole and tamoxifen appeared to increase in a nonproportional manner with increasing doses. Exposure of ortho- and para-hydroxyatorvastatin, but not atorvastatin and lactone, increased proportionally with increasing doses. LC-MS/MS has demonstrated its usefulness for detecting and characterizing the major metabolites in plasma and urine at microdosing levels in rats. The exposure of metabolites at microdose could not simply be used to predict their exposure at higher doses.

  4. Multiclass determination and confirmation of antibiotic residues in honey using LC-MS/MS.

    Science.gov (United States)

    Lopez, Mayda I; Pettis, Jeffery S; Smith, I Barton; Chu, Pak-Sin

    2008-03-12

    A multiclass method has been developed for the determination and confirmation in honey of tetracyclines (chlortetracycline, doxycycline, oxytetracycline, and tetracycline), fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, and sarafloxacin), macrolides (tylosin), lincosamides (lincomycin), aminoglycosides (streptomycin), sulfonamides (sulfathiazole), phenicols (chloramphenicol), and fumagillin residues using liquid chromatography tandem mass spectrometry (LC-MS/MS). Erythromycin (a macrolide) and monensin (an ionophore) can be detected and confirmed but not quantitated. Honey samples (approximately 2 g) are dissolved in 10 mL of water and centrifuged. An aliquot of the supernatant is used to determine streptomycin. The remaining supernatant is filtered through a fine-mesh nylon fabric and cleaned up by solid phase extraction. After solvent evaporation and sample reconstitution, 15 antibiotics are assayed by LC-MS/MS using electrospray ionization (ESI) in positive ion mode. Afterward, chloramphenicol is assayed using ESI in negative ion mode. The method has been validated at the low part per billion levels for most of the drugs with accuracies between 65 and 104% and coefficients of variation less than 17%. The evaluation of matrix effects caused by honey of different floral origin is presented.

  5. The development and validation of an UHPLC–MS/MS method for the rapid quantification of the antiretroviral agent dapivirine in human plasma

    Science.gov (United States)

    Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A

    2014-01-01

    Background Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Results Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. Conclusion A robust and sensitive LC–MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials. PMID:24256358

  6. Characterization of Proteins Present in Isolated Senile Plaques from Alzheimer's Diseased Brains by MALDI-TOF MS with MS/MS.

    Science.gov (United States)

    Kelley, Andrea R; Perry, George; Bach, Stephan B H

    2018-04-18

    The increase of insoluble senile plaques in the brain is a primary hallmark of Alzheimer's disease. The usefulness of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) with tandem MS for the characterization of senile plaques from AD brains and the relevance of the components identified to furthering AD research using MS is discussed. Thirty-three components were reproducibly observed within tryptic aliquots of senile plaques from two different AD brains after sample preparation optimization. Additionally, this is one of the first accounts of LIFT being utilized for the direct sequencing of peptides from isolated senile plaques. While many of the species observed coisolated within senile plaques have been linked to AD etiology, if only speculatively, this is the first instance that many of them have been demonstrated to be a part of the plaques themselves. This work is the first step in determining the potential roles that the species may have in the aggregation or proliferation of the plaques.

  7. Short Communication: Testosterone Measured with an Automatic Immunoassay Compares Reasonbly Well to Results Obtained by LC-MS/MS

    DEFF Research Database (Denmark)

    Knudsen, Cindy Søndersø; Højskov, Carsten Schriver; Møller, Holger Jon

    2016-01-01

    Background: Previous studies have reported problems measuring testosterone with immunological assays. Here we explore an automatic second generation immunoassay compared to a LC-MS/MS method. Methods: We collected blood samples from 76 women and measured testosterone, progesterone, gender...... hormonebinding globulin (SHBG), and albumin employing Cobas e601/c501. Testosterone, androstenedione (andro), dehydroepiandrosterone sulphate (DHEAS), and 17-hydroxyprogesterone (17-OHP) concentrations were measured employing LC-MS/MS. We evaluated the difference between testosterone measured by the two methods...... and examined the potential interference from the selected steroids and bindings proteins. Results: Testosterone concentrations measured by the two methods yielded: Cobas e601 = 1.240 x (LC-MS/MS) - 0.197, r = 0.84, for testosterone concentrations between 0.22 - 4.9 nmol/L. A positive correlation was observed...

  8. Metabolism of the new psychoactive substances N,N-diallyltryptamine (DALT) and 5-methoxy-DALT and their detectability in urine by GC-MS, LC-MSn, and LC-HR-MS-MS.

    Science.gov (United States)

    Michely, Julian A; Helfer, Andreas G; Brandt, Simon D; Meyer, Markus R; Maurer, Hans H

    2015-10-01

    N,N-Diallyltryptamine (DALT) and 5-methoxy-DALT (5-MeO-DALT) are synthetic tryptamine derivatives commonly referred to as so-called new psychoactive substances (NPS). They have psychoactive effects that may be similar to those of other tryptamine derivatives. The objectives of this work were to study the metabolic fate and detectability, in urine, of DALT and 5-MeO-DALT. For metabolism studies, rat urine obtained after high-dose administration was prepared by precipitation and analyzed by liquid chromatography-high-resolution mass spectrometry (LC-HR-MS-MS). On the basis of the metabolites identified, several aromatic and aliphatic hydroxylations, N-dealkylation, N-oxidation, and combinations thereof are proposed as the main metabolic pathways for both compounds. O-Demethylation of 5-MeO-DALT was also observed, in addition to extensive glucuronidation or sulfation of both compounds after phase I transformation. The cytochrome P450 (CYP) isoenzymes predominantly involved in DALT metabolism were CYP2C19, CYP2D6, and CYP3A4; those mainly involved in 5-MeO-DALT metabolism were CYP1A2, CYP2C19, CYP2D6, and CYP3A4. For detectability studies, rat urine was screened by GC-MS, LC-MS(n), and LC-HR-MS-MS after administration of low doses. LC-MS(n) and LC-HR-MS-MS were deemed suitable for monitoring consumption of both compounds. The most abundant targets were a ring hydroxy metabolite of DALT, the N,O-bis-dealkyl metabolite of 5-MeO-DALT, and their glucuronides. GC-MS enabled screening of DALT by use of its main metabolites only.

  9. Screening of veterinary drug residues in food by LC-MS/MS. Background and challenges.

    Science.gov (United States)

    Delatour, Thierry; Racault, Lucie; Bessaire, Thomas; Desmarchelier, Aurélien

    2018-04-01

    Regulatory agencies and government authorities have established maximum residue limits (MRL) in various food matrices of animal origin for supporting governments and food operators in the monitoring of veterinary drug residues in the food chain, and ultimately in the consumer's plate. Today, about 200 veterinary drug residues from several families, mainly with antibiotic, antiparasitic or antiinflammatory activities, are regulated in a variety of food matrices such as milk, meat or egg. This article provides a review of the regulatory framework in milk and muscle including data from Codex Alimentarius, Europe, the U.S.A., Canada and China for about 220 veterinary drugs. The article also provides a comprehensive overview of the challenge for food control, and emphasizes the pivotal role of liquid chromatography-mass spectrometry (LC-MS), either in tandem with quadrupoles (LC-MS/MS) or high resolution MS (LC-HRMS), for ensuring an adequate consumer protection combined with an affordable cost. The capability of a streamlined LC-MS/MS platform for screening 152 veterinary drug residues in a broad range of raw materials and finished products is highlighted in a production line perspective. The rationale for a suite of four methods intended to achieve appropriate performance in terms of scope and sensitivity is presented. Overall, the platform encompasses one stream for the determination of 105 compounds in a run (based on acidic QuEChERS-like), plus two streams for 23 β-lactams (alkaline QuEChERS-like) and 10 tetracyclines (low-temperature partitioning), respectively, and a dedicated stream for 14 aminoglycosides (molecularly-imprinted polymer).

  10. Determination method for 129I in soil samples by MIP-MS

    International Nuclear Information System (INIS)

    Uezu, Yasuhiro; Nakano, Masanao; Fujita, Hiroki; Watanabe, Hitoshi; Maruo, Yoshihiro

    2001-01-01

    The radioactive iodine-129 ( 129 I) is an important radionuclide for environmental assessment because it has a long half-life and is accumulated in the thyroid gland in humans. A new analytical technique by Microwave Induced Plasma Mass Spectrometer (MIP-MS) was applied to the determination of 129 I in soil samples. In environmental samples, a large amount of matrix elements are present. Therefore, the matrix elements were eliminated by ashing at 1000degC, and iodine isotopes were trapped by an activated charcoal and finally extracted by 10% tetramethylammonium hydroxide (TMAH). The concentration of 129 I in a soil samples were compared between results of neutron activation analysis and MIP-MS method. The results showed an excellent agreement. (author)

  11. A laser ablation ICP-MS based method for multiplexed immunoblot analysis

    DEFF Research Database (Denmark)

    de Bang, Thomas Christian; Petersen, Jørgen; Pedas, Pai Rosager

    2015-01-01

    developed a multiplexed antibody-based assay and analysed selected PSII subunits in barley (Hordeum vulgare L.). A selection of antibodies were labelled with specific lanthanides and immunoreacted with thylakoids exposed to Mn deficiency after western blotting. Subsequently, western blot membranes were...... analysed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), which allowed selective and relative quantitative analysis via the different lanthanides. The method was evaluated against established liquid chromatography electrospray ionization tandem mass spectrometry (LC...... by more than one technique. The developed method enables a higher number of proteins to be multiplexed in comparison to existing immunoassays. Furthermore, multiplexed protein analysis by LA-ICP-MS provides an analytical platform with high throughput appropriate for screening large collections of plants....

  12. The role of EBV in MS pathogenesis

    DEFF Research Database (Denmark)

    Christensen, Tove

    2006-01-01

    Environmental factors operate on a background of genetic susceptibility in the pathogenesis of MS. Human herpesviruses, notably Epstein-Barr virus (EBV), and human endogenous retroviruses are factors associated with MS. EBV association is found in epidemiological surveys where late EBV infection...... confers a higher risk of MS, and EBV reactivation also appears to be linked to disease activity in early MS. MS patients have elevated anti-EBV antibody responses, both in serum and cerebrospinal fluid. Molecular mimicry is found between certain EBV and myelin epitopes in the cell-mediated immune response....... EBV cannot stand alone as a causal factor of MS, but is likely to play an indirect role as an activator of the underlying disease process....

  13. Placentite fúngica em eqüino: relato de caso / Fungi placentitis in equines: a case report

    Directory of Open Access Journals (Sweden)

    Jayme Augusto Peres

    2008-05-01

    Full Text Available O fungo Aspergillus fumigatus é saprófi ta e oportunista e é o de maior ocorrência em infecções fúngicas nos animais, com capacidade de produzir endotoxinas. Possui hifas septadas e pode ser encontrado no solo, na vegetação, nos alimentos e também em material fermentado de origem vegetal, como silagem, feno e adubo químico. A transmissão ocorre mais comumente pela inalação ou ingestão. Nos eqüinos, a infecção da bolsa gutural resulta numa síndrome clínica caracterizada por sangramento nasal recorrente, associada a alterações visuais e locomotoras, podendo disseminar-se da cavidade nasal e via nervos óticos para o quiasma ótico e o cérebro. Abortos micóticos são esporádicos em eqüinos, ocorrendo geralmente no terço fi nal da gestação, causando placentite necrótica e lesões dermatológicas no feto. O presente relato descreve a ocorrência de morte fetal e materna de uma égua da raça crioula com seis anos e oito meses de idade. O óbito aconteceu quarenta e oito horas após o desenvolvimento dos sinais clínicos de prostração, febre e insufi ciência cardio-respiratória, acompanhada de icterícia das mucosas aparentes. Durante o exame necroscópico, realizado no laboratório de Anatomia Patológica Veterinária da UNICENTRO, foram observadas alterações circulatórias viscerais generalizadas e dermatite difusa no feto. O exame do Imprint das lesões, em microscopia óptica, corado pelo método Panótico demonstrou a presença de hifas fúngicas septadas, caracterizando placentite fúngica por aspergilose.

  14. Application of the ruthenium and technetium thermodynamic data bases used in the EQ3/6 geochemical codes

    Energy Technology Data Exchange (ETDEWEB)

    Isherwood, D.

    1985-04-01

    Based on a critical review of the available thermodynamic data, computerized data bases for technetium and ruthenium were created for use with the EQ3/6 geochemical computer codes. The technetium data base contains thermodynamic data for 8 aqueous species and 15 solids; 26 aqueous species and 9 solids were included in the ruthenium data base. The EQ3NR code was used to calculate solubility limits for ruthenium (8 x 10{sup -16} M) in ground water from Yucca Mountain, a potential nuclear waste repository site near the Nevada Test Site (NTS). The code confirmed the essentially unlimited solubility of technetium in oxidizing conditions, such as those that are believed to exist in the unsaturated zone at Yucca Mountain and the Cambric Nuclear event site at the NTS. Ruthenium migration observed from the Cambric site was evaluated. The solubility limit for ruthenium (as the aqueous species RuO{sub 4}{sup -}) when constrained by RuO{sub 2} is approximately equal to the concentration of ruthenium found in the cavity ground water (i.e., 2.1 x 10{sup -11} vs 4.5 x 10{sup -11} M). Differences in ruthenium solubility limits between Yucca Mountain and Cambric are primarily due to differences in ground-water pH. Technetium solubility (3 x 10{sup -8} M) for moderately reducing conditions (Eh = -0.1 V) using the metastable oxide, TcO{sub 2}.2H{sub 2}O, as the solubility constraint is within the range of experimental values recently published in a study of technetium sorption on basalt. Previously published technetium solubilities of 10{sup -12} to 10{sup -16} M were apparently based on a technetium data base that did not include aqueous species other than TcO{sub 4}{sup -}. When TcO(OH){sub 2}{sup 0} is included in the data base, the calculated values are much closer to the experimental results. Eh-pH diagrams were also generated for a variety of conditions using the SOLUPLOT code.

  15. Application of the ruthenium and technetium thermodynamic data bases used in the EQ3/6 geochemical codes

    International Nuclear Information System (INIS)

    Isherwood, D.

    1985-04-01

    Based on a critical review of the available thermodynamic data, computerized data bases for technetium and ruthenium were created for use with the EQ3/6 geochemical computer codes. The technetium data base contains thermodynamic data for 8 aqueous species and 15 solids; 26 aqueous species and 9 solids were included in the ruthenium data base. The EQ3NR code was used to calculate solubility limits for ruthenium (8 x 10 -16 M) in ground water from Yucca Mountain, a potential nuclear waste repository site near the Nevada Test Site (NTS). The code confirmed the essentially unlimited solubility of technetium in oxidizing conditions, such as those that are believed to exist in the unsaturated zone at Yucca Mountain and the Cambric Nuclear event site at the NTS. Ruthenium migration observed from the Cambric site was evaluated. The solubility limit for ruthenium (as the aqueous species RuO 4 - ) when constrained by RuO 2 is approximately equal to the concentration of ruthenium found in the cavity ground water (i.e., 2.1 x 10 -11 vs 4.5 x 10 -11 M). Differences in ruthenium solubility limits between Yucca Mountain and Cambric are primarily due to differences in ground-water pH. Technetium solubility (3 x 10 -8 M) for moderately reducing conditions (Eh = -0.1 V) using the metastable oxide, TcO 2 .2H 2 O, as the solubility constraint is within the range of experimental values recently published in a study of technetium sorption on basalt. Previously published technetium solubilities of 10 -12 to 10 -16 M were apparently based on a technetium data base that did not include aqueous species other than TcO 4 - . When TcO(OH) 2 0 is included in the data base, the calculated values are much closer to the experimental results. Eh-pH diagrams were also generated for a variety of conditions using the SOLUPLOT code

  16. Developments in FT-ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics.

    Science.gov (United States)

    Cho, Yunju; Ahmed, Arif; Islam, Annana; Kim, Sunghwan

    2015-01-01

    Because of the increasing importance of heavy and unconventional crude oil as an energy source, there is a growing need for petroleomics: the pursuit of more complete and detailed knowledge of the chemical compositions of crude oil. Crude oil has an extremely complex nature; hence, techniques with ultra-high resolving capabilities, such as Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), are necessary. FT-ICR MS has been successfully applied to the study of heavy and unconventional crude oils such as bitumen and shale oil. However, the analysis of crude oil with FT-ICR MS is not trivial, and it has pushed analysis to the limits of instrumental and methodological capabilities. For example, high-resolution mass spectra of crude oils may contain over 100,000 peaks that require interpretation. To visualize large data sets more effectively, data processing methods such as Kendrick mass defect analysis and statistical analyses have been developed. The successful application of FT-ICR MS to the study of crude oil has been critically dependent on key developments in FT-ICR MS instrumentation and data processing methods. This review offers an introduction to the basic principles, FT-ICR MS instrumentation development, ionization techniques, and data interpretation methods for petroleomics and is intended for readers having no prior experience in this field of study. © 2014 Wiley Periodicals, Inc.

  17. Ellagitannin composition of blackberry as determined by HPLC-ESI-MS and MALDI-TOF-MS.

    Science.gov (United States)

    Hager, Tiffany J; Howard, Luke R; Liyanage, Rohana; Lay, Jackson O; Prior, Ronald L

    2008-02-13

    Blackberries ( Rubus sp.) were evaluated by high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF-MS) to identify the ellagitannins present in flesh, torus (receptacle tissue), and seeds. Most ellagitannins were present (or detectable) only in seed tissues. Ellagitannins identified by HPLC-ESI-MS in the seeds included pedunculagin, casuarictin/potentillin, castalagin/vescalagin, lambertianin A/sanguiin H-6, lambertianin C, and lambertianin D. For several of the ellagitannins, isomeric separation was also obtained. The MALDI-TOF-MS analysis was primarily utilized to evaluate and identify high molecular mass (>1000 Da) ellagitannins. The MALDI analysis verified the presence of the ellagitannins identified by HPLC-ESI-MS including lambertianin A/sanguiin H-6, lambertianin C, and lambertianin D, but the analysis also indicated the presence of several other compounds that were most likely ellagitannins based on the patterns observed in the masses (i.e., loss or addition of a gallic acid moiety to a known ellagitannin). This study determined the presence of several possible isomeric forms of ellagitannins previously unidentified in fruit and presents a possible analytical HPLC method for the analysis of the major ellagitannins present in the fruit.

  18. Capillary Isotachophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring MS via a Novel Sheathless Interface for High Sensitivity Sample Quantification

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chenchen (Chloe); Lee, Cheng S.; Smith, Richard D.; Tang, Keqi

    2013-06-21

    A novel sheathless CITP/CZE-MS interface featuring a large i.d. separation capillary and a detachable small i.d. ESI emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantitation (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with excellent measurement reproducibility were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.

  19. Validation of a LC-MS/MS method for quantifying urinary nicotine, six nicotine metabolites and the minor tobacco alkaloids--anatabine and anabasine--in smokers' urine.

    Directory of Open Access Journals (Sweden)

    James E McGuffey

    Full Text Available Tobacco use is a major contributor to premature morbidity and mortality. The measurement of nicotine and its metabolites in urine is a valuable tool for evaluating nicotine exposure and for nicotine metabolic profiling--i.e., metabolite ratios. In addition, the minor tobacco alkaloids--anabasine and anatabine--can be useful for monitoring compliance in smoking cessation programs that use nicotine replacement therapy. Because of an increasing demand for the measurement of urinary nicotine metabolites, we developed a rapid, low-cost method that uses isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS for simultaneously quantifying nicotine, six nicotine metabolites, and two minor tobacco alkaloids in smokers' urine. This method enzymatically hydrolyzes conjugated nicotine (primarily glucuronides and its metabolites. We then use acetone pretreatment to precipitate matrix components (endogenous proteins, salts, phospholipids, and exogenous enzyme that may interfere with LC-MS/MS analysis. Subsequently, analytes (nicotine, cotinine, hydroxycotinine, norcotinine, nornicotine, cotinine N-oxide, nicotine 1'-N-oxide, anatabine, and anabasine are chromatographically resolved within a cycle time of 13.5 minutes. The optimized assay produces linear responses across the analyte concentrations typically found in urine collected from daily smokers. Because matrix ion suppression may influence accuracy, we include a discussion of conventions employed in this procedure to minimize matrix interferences. Simplicity, low cost, low maintenance combined with high mean metabolite recovery (76-99%, specificity, accuracy (0-10% bias and reproducibility (2-9% C.V. make this method ideal for large high through-put studies.

  20. Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samples.

    Science.gov (United States)

    Fang, Nianbai; Yu, Shanggong; Ronis, Martin Jj; Badger, Thomas M

    2015-04-01

    High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-peak with reliable retention time (Rt.). However, in the current study, we have found that under the same LC-MS conditions, the Rt. and shape of LC-peaks of bile acids in urine samples from animals fed dissimilar diets differed significantly among each other. To verify this matrix effect, 17 authentic bile acid standards were dissolved in pure methanol or in methanol containing extracts of urine from pigs consuming either breast milk or infant formula and analyzed by LC-MS/MS. The matrix components in urine from piglets fed formula significantly reduced the LC-peak Rt. and areas of bile acids. This is the first characterization of this matrix effect on Rt. in the literature. Moreover, the matrix effect resulted in an unexpected LC behavior: one single compound yielded two LC-peaks, which broke the rule of one LC-peak for one compound. The three bile acid standards which exhibited this unconventional LC behavior were chenodeoxycholic acid, deoxycholic acid, and glycocholic acid. One possible explanation for this effect is that some matrix components may have loosely bonded to analytes, which changed the time analytes were retained on a chromatography column and interfered with the ionization of analytes in the MS ion source to alter the peak area. This study indicates that a comprehensive understanding of matrix effects is needed towards improving the use of HPLC and LC-MS/MS techniques for qualitative and quantitative analyses of analytes in pharmacokinetics, proteomics/metabolomics, drug development, and sports drug testing, especially when LC-MS/MS data are analyzed by automation software where identification of an analyte is based on its exact molecular weight and Rt

  1. IsoMS: automated processing of LC-MS data generated by a chemical isotope labeling metabolomics platform.

    Science.gov (United States)

    Zhou, Ruokun; Tseng, Chiao-Li; Huan, Tao; Li, Liang

    2014-05-20

    A chemical isotope labeling or isotope coded derivatization (ICD) metabolomics platform uses a chemical derivatization method to introduce a mass tag to all of the metabolites having a common functional group (e.g., amine), followed by LC-MS analysis of the labeled metabolites. To apply this platform to metabolomics studies involving quantitative analysis of different groups of samples, automated data processing is required. Herein, we report a data processing method based on the use of a mass spectral feature unique to the chemical labeling approach, i.e., any differential-isotope-labeled metabolites are detected as peak pairs with a fixed mass difference in a mass spectrum. A software tool, IsoMS, has been developed to process the raw data generated from one or multiple LC-MS runs by peak picking, peak pairing, peak-pair filtering, and peak-pair intensity ratio calculation. The same peak pairs detected from multiple samples are then aligned to produce a CSV file that contains the metabolite information and peak ratios relative to a control (e.g., a pooled sample). This file can be readily exported for further data and statistical analysis, which is illustrated in an example of comparing the metabolomes of human urine samples collected before and after drinking coffee. To demonstrate that this method is reliable for data processing, five (13)C2-/(12)C2-dansyl labeled metabolite standards were analyzed by LC-MS. IsoMS was able to detect these metabolites correctly. In addition, in the analysis of a (13)C2-/(12)C2-dansyl labeled human urine, IsoMS detected 2044 peak pairs, and manual inspection of these peak pairs found 90 false peak pairs, representing a false positive rate of 4.4%. IsoMS for Windows running R is freely available for noncommercial use from www.mycompoundid.org/IsoMS.

  2. Changing activity in MS lesions

    International Nuclear Information System (INIS)

    Kermode, A.G.; Tofts, P.S.; Thompson, A.J.; Rudge, P.; MacManus, D.G.; Kendall, B.E.; Moseley, I.F.; Kingsley, D.P.E.; McDonald, W.I.

    1989-01-01

    Gd-DTPA enhanced T1 weighted MRI is a discriminating test for a defective blood-brain barrier, with MS lesions showing considerable variation in the pattern of enhancement. Since little is known of the changes in the blood-brain barrier in the active plaque over time, the natural history of blood-brain barrier disturbance in the MS lesion was examined to confirm earlier reports that Gd-DTPA enhancement is a consistent early event in new lesions of relapsing/remitting MS. This knowledge is essential for the use of MRI in monitoring treatment. (author). 9 refs

  3. ICP-MS: suitable method to study the metals distribution in estuarine regions; ICP-MS metodo adequado para o estudo da distribuicao de metais em regioes estuarinas

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, Danilo C.; Oliveira, Arno H. [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear]. E-mail: danilochagas@yahoo.com.br; heeren@nuclear.ufmg.br; Santos, Silvio J. dos; Brito, Veronica F.O.; Severo, Maria Isabel G. [Universidade Estadual de Santa Cruz, Ilheus, BA (Brazil). Dept. de Ciencias Biologicas

    2005-07-01

    Anthropogenic inputs of pollutants such as heavy metals into the marine environment have increased their levels to large extents within past a few decades. These pollutants tend to accumulate in the bottom sediments. As a result, ecosystems such as seaports or other industrialized coastal areas that have chronic inputs of metals have highly contaminated sediments. This characteristic has led to concerns over the ecological effects that may be associated with sediment quality. Of particular concern are toxic effects and the potential for bioaccumulation of metals in biota exposed to the sediments. The bivalves Crassostrea rhizophorae, Lucina pectinata and Mytella falcata have been used as biomonitors of trace metal contamination in two estuaries from Ilheus city, Bahia state, in Brazil. Bivalves, sediment and water samples were collected in March 2004 in Acuipe and Rio do Engenho mangroves. The proposed technique to analyze the studied matrices was the inductively coupled plasma mass spectrometry (ICP-MS). The results suggested that the studied molluscs are bioaccumulators of metals and showed the Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) as an adequate technique to determine a large range of inorganic elements, because its high sensibility and low detection limits. (author)

  4. Postmortem Kanda LC-MS MS ile Yasadışı Madde Taraması 62 Postmortem Adli Olguda Uygulanması

    Directory of Open Access Journals (Sweden)

    Serap Annette Akgür

    2007-04-01

    Full Text Available Biyolojik örneklerdeki yasadışı madde taraması adli olaylarda büyük bir öneme sahiptir. Kan veya plazma, madde derişim-leri ile bu maddelerin farmakolojik etkileri arasında iyi bir korelasyonun bulunması nedeniyle genellikle tercih edilen materyallerdir. Yasadışı madde analizinde, birçok laboratuar immunoassay yöntemleri ile tarama ve Gaz Kromatografi-Kütle Spektrometresi (GC-MS ile doğrulama şeklinde bir uygulama yapmaktadır. Bununla birlikte, sıvı kromatografi tekniklerinin gelişmesiyle birlikte Sıvı Kromatografisi-Kütle Spektrometresi (LC-MS ve tandem LC-MS (LC-MS/MS birleştirilmiş tekniklerinde özellikle polar ve ısıya dayanıksız olan maddelerin nitel ve nicel analiz amaçlı olarak kullanımı zamanla artmaktadır. Bu çalışmada, LC-ESI (Electrospray İonisation-MS/MS de morfin, (±-amfetamin, (+-metamfetamin, kokain, benzolekgonin, kokaetilen ve (--ll-nor-9-karboksi-t9-THC maddeleri taranmış ve tayin edilmiştir. Sonuç olarak, postmortem kanda uygulanabilecek, türevlendirme işlemine gerek duymayan, duyarlı ve seçimli olarak, çok düşük düzeylerdeki maddelerin doğru ve kesin olarak saptanmasını sağlayacak, LC-MS/MS yöntemi geliştirilmiş ve 62 postmortem adli olguya başarıyla uygulanmıştır. Anahtar kelimeler: Yasadışı madde, tarama, LC/MS/MS, postmortem kan

  5. Controle público e eqüidade no acesso a hospitais sob gestão pública não estatal Public control and equity of access to hospitals under non-State public administration

    Directory of Open Access Journals (Sweden)

    Nivaldo Carneiro Junior

    2006-10-01

    Full Text Available OBJETIVO: Analisar as organizações sociais de saúde à luz do controle público e da garantia da eqüidade no acesso aos serviços de saúde. MÉTODOS: Utilizou-se a técnica de estudo de caso e foram selecionadas duas organizações sociais de saúde na região metropolitana de São Paulo. As categorias analíticas foram eqüidade no acesso e controle público, baseando-se em entrevistas com informantes-chave e relatórios técnico-administrativos. RESULTADOS: Observou-se que financiamento global e o controle administrativo das organizações sociais de saúde são atribuições do gestor estadual. A presença do gestor local é importante para a garantia da eqüidade no acesso, sendo que o controle público se expressa por ações fiscalizadoras mediante procedimentos contábil-financeiros. CONCLUSÕES: A eqüidade no acesso e o controle público não são contemplados na gestão dessas organizações. A questão central encontra-se na capacidade do poder público se fazer presente na implementação dessa modalidade no âmbito local, garantido a eqüidade no acesso e contemplando o controle público.OBJECTIVE: To analyze social health organizations in the light of public control and the guarantee of equity of access to health services. METHODS: Utilizing the case study technique, two social health organizations in the metropolitan region of São Paulo were selected. The analytical categories were equity of access and public control, and these were based on interviews with key informants and technical-administrative reports. RESULTS: It was observed that the overall funding and administrative control of the social health organizations are functions of the state administrator. The presence of a local administrator is important for ensuring equity of access. Public control is expressed through supervisory actions, by means of accounting and financial procedures. CONCLUSIONS: Equity of access and public control are not taken into consideration

  6. Piodermite profunda por Staphylococcus intermedius em eqüino Deep pyoderma by Staphylococcus intermedius in equine

    Directory of Open Access Journals (Sweden)

    Fábio Cordeiro Oliveira Santos

    2008-12-01

    Full Text Available Neste trabalho descreve-se um caso de piodermite, com tempo de evolução de um mês, de um eqüino de oito anos de idade, sem raça definida, com áreas alopécicas, crostas na pálpebra superior, nos membros torácicos e pélvicos, na região do prepúcio e, principalmente, na região do pescoço e escápula. O prurido era discreto. O exame histopatológico revelou dermatite piogranulomatosa perivascular e perianexial associada à hiperplasia epidérmica, além de orto e paraceratose e crostas. O epitélio folicular exibiu focos de espongiose e exocitose de neutrófilos, predominando aspectos de inflamação crônica. A cultura bacteriana identificou o Staphylococcus intermedius a partir das suas características morfo-tintoriais e bioquímicas, com resultados positivos aos testes de catalase, coagulase, glicose e produção ácida aeróbica a partir do manitol. O eqüino foi tratado diariamente com dimetilsulfóxido, gentamicina e dexametasona por via tópica. Mesmo que algumas das lesões apresentaram rápida regressão (sete dias, as localizadas na região do pescoço e escápula demoraram 13 meses para a completa cicatrização.A case of one month of evolution, of an 8-year-old equine of undefined breed, presenting alopecic areas, crusts on the upper eyelid, forelimbs, hindlimbs, preputial region and mainly, on the neck and scapula is reported. Pruritus was discrete. The histological analysis revealed pyogranulomatous dermatitis round blood vessels and adnexa, associated with epidermal hyperplasia, as well as orthokeratosis, parakeratosis and crusts. The follicular epithelium exhibited foci of spongiosis and exocytosis of neutrophils, with predominant chronic inflammation changes. Bacterial culture identified Staphylococcus intermedius, based on morphology, staining and biochemical tests positive for catalase, coagulase, glucose and aerobic acid production from mannitol. The equine was treated with dimethylsulfoxide, gentamicine and

  7. RAId_aPS: MS/MS analysis with multiple scoring functions and spectrum-specific statistics.

    Science.gov (United States)

    Alves, Gelio; Ogurtsov, Aleksey Y; Yu, Yi-Kuo

    2010-11-16

    Statistically meaningful comparison/combination of peptide identification results from various search methods is impeded by the lack of a universal statistical standard. Providing an E-value calibration protocol, we demonstrated earlier the feasibility of translating either the score or heuristic E-value reported by any method into the textbook-defined E-value, which may serve as the universal statistical standard. This protocol, although robust, may lose spectrum-specific statistics and might require a new calibration when changes in experimental setup occur. To mitigate these issues, we developed a new MS/MS search tool, RAId_aPS, that is able to provide spectrum-specific-values for additive scoring functions. Given a selection of scoring functions out of RAId score, K-score, Hyperscore and XCorr, RAId_aPS generates the corresponding score histograms of all possible peptides using dynamic programming. Using these score histograms to assign E-values enables a calibration-free protocol for accurate significance assignment for each scoring function. RAId_aPS features four different modes: (i) compute the total number of possible peptides for a given molecular mass range, (ii) generate the score histogram given a MS/MS spectrum and a scoring function, (iii) reassign E-values for a list of candidate peptides given a MS/MS spectrum and the scoring functions chosen, and (iv) perform database searches using selected scoring functions. In modes (iii) and (iv), RAId_aPS is also capable of combining results from different scoring functions using spectrum-specific statistics. The web link is http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/raid_aps/index.html. Relevant binaries for Linux, Windows, and Mac OS X are available from the same page.

  8. Environmental contaminants of honeybee products in Uganda detected using LC-MS/MS and GC-ECD.

    Directory of Open Access Journals (Sweden)

    Deborah Ruth Amulen

    Full Text Available Pollinator services and the development of beekeeping as a poverty alleviating tool have gained considerable focus in recent years in sub-Saharan Africa. An improved understanding of the pervasive environmental extent of agro-chemical contaminants is critical to the success of beekeeping development and the production of clean hive products. This study developed and validated a multi-residue method for screening 36 pesticides in honeybees, honey and beeswax using LC-MS/MS and GC-ECD. Of the 36 screened pesticides, 20 were detected. The highest frequencies occurred in beeswax and in samples from apiaries located in the proximity of citrus and tobacco farms. Fungicides were the most prevalent chemical class. Detected insecticides included neonicotinoids, organophosphates, carbamates, organophosphorus, tetrazines and diacylhydrazines. All detected pesticide levels were below maximum residue limits (according to EU regulations and the lethal doses known for honeybees. However, future risk assessment is needed to determine the health effects on the African genotype of honeybees by these pesticide classes and combinations of these. In conclusion, our data present a significant challenge to the burgeoning organic honey sector in Uganda, but to achieve this, there is an urgent need to regulate the contact routes of pesticides into the beehive products. Interestingly, the "zero" detection rate of pesticides in the Mid-Northern zone is a significant indicator of the large potential to promote Ugandan organic honey for the export market.

  9. Identification of the Chemical Constituents in Simiao Wan and Rat Plasma after Oral Administration by GC-MS and LC-MS

    Directory of Open Access Journals (Sweden)

    Yunshuang Fan

    2017-01-01

    Full Text Available Simiao Wan (SMW, an important multiherbal formula used in traditional Chinese medicine, is extensively used to treat rheumatoid arthritis. However, the knowledge of the bioactive components of SMW remains unclear. Thus, gas chromatography–mass spectrometry (GC-MS and liquid chromatography–mass spectrometry (LC-MS were used to analyze the chemical constituents of volatile and nonvolatile extracts of SMW, as well as its absorbed components in rat plasma after oral SMW administration. Identification of several compounds was enabled by comparison of retention times, MS spectra, and MS/MS spectral data with the standard substance and reference materials reported in the literature. In the volatile extracts, GC-MS identified 26 compounds in vitro, three of which observed in blood by GC-MS. In the nonvolatile extracts, LC-MS identified 49 compounds in SMW; 18 compounds containing 7 prototype compounds, 5 metabolites, and 6 unknown compounds were absorbed by blood. The proposed GC-MS and LC-MS method was appropriate not only for the rapid screening and identification of multiple components of an SMW extract but also for screening its bioactive constituents in vivo. The proposed method could be a promising tool for the quality control of other Chinese herbal medicines.

  10. Determination of chlormequat in pig serum and sow milk by LC-MS/MS.

    Science.gov (United States)

    Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H

    2007-11-01

    Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.

  11. Determination of selected bisphenols, parabens and estrogens in human plasma using LC-MS/MS

    Czech Academy of Sciences Publication Activity Database

    Kolatorova Sosvorova, L.; Chlupacova, T.; Vitku, J.; Vlk, Martin; Heráček, J.; Stárka, L.; Šaman, David; Šimková, M.; Hampl, R.

    2017-01-01

    Roč. 174, NOV 1 (2017), s. 21-28 ISSN 0039-9140 Institutional support: RVO:61389030 ; RVO:61388963 Keywords : Alternative bisphenol * Bisphenol A * Bisphenol F * Endocrine disruptor * lc-ms/ms * Paraben Subject RIV: CC - Organic Chemistry OBOR OECD: Analytical chemistry; Organic chemistry (UOCHB-X) Impact factor: 4.162, year: 2016

  12. Direct, rapid quantitative analyses of BVOCs using SIFT-MS and PTR-MS obviating sample collection

    Czech Academy of Sciences Publication Activity Database

    Smith, D.; Španěl, Patrik

    2011-01-01

    Roč. 30, č. 7 (2011), s. 945-959 ISSN 0165-9936 Institutional research plan: CEZ:AV0Z40400503 Keywords : SIFT-MS * PTR-MS * Absolute quantification Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 6.273, year: 2011

  13. Presence and significant determinants of cognitive impairment in a large sample of patients with multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Martina Borghi

    Full Text Available OBJECTIVES: To investigate the presence and the nature of cognitive impairment in a large sample of patients with Multiple Sclerosis (MS, and to identify clinical and demographic determinants of cognitive impairment in MS. METHODS: 303 patients with MS and 279 healthy controls were administered the Brief Repeatable Battery of Neuropsychological tests (BRB-N; measures of pre-morbid verbal competence and neuropsychiatric measures were also administered. RESULTS: Patients and healthy controls were matched for age, gender, education and pre-morbid verbal Intelligence Quotient. Patients presenting with cognitive impairment were 108/303 (35.6%. In the overall group of participants, the significant predictors of the most sensitive BRB-N scores were: presence of MS, age, education, and Vocabulary. The significant predictors when considering MS patients only were: course of MS, age, education, vocabulary, and depression. Using logistic regression analyses, significant determinants of the presence of cognitive impairment in relapsing-remitting MS patients were: duration of illness (OR = 1.053, 95% CI = 1.010-1.097, p = 0.015, Expanded Disability Status Scale score (OR = 1.247, 95% CI = 1.024-1.517, p = 0.028, and vocabulary (OR = 0.960, 95% CI = 0.936-0.984, p = 0.001, while in the smaller group of progressive MS patients these predictors did not play a significant role in determining the cognitive outcome. CONCLUSIONS: Our results corroborate the evidence about the presence and the nature of cognitive impairment in a large sample of patients with MS. Furthermore, our findings identify significant clinical and demographic determinants of cognitive impairment in a large sample of MS patients for the first time. Implications for further research and clinical practice were discussed.

  14. Factors Associated with Neurologists' Provision of MS Patient Care

    Science.gov (United States)

    Halpern, Michael T.; Teixeira-Poit, Stephanie M.; Kane, Heather; Frost, Corey; Keating, Michael; Olmsted, Murrey

    2014-01-01

    Neurologists are central to providing quality care for individuals with MS. However, neurologist shortages may restrict access to care for MS patients. To examine factors influencing neurologists' provision of MS care, we surveyed 1,700 US neurologists to assess demographic/practice characteristics, training, and attitudes toward MS care. The study population consisted of 573 respondents: 87 (15.2%) MS subspecialists and 486 (84.8%) “other neurologists,” including subspecialists in other neurology areas (i.e., non-MS) and general neurologists. MS subspecialists indicating they “enjoy interacting with MS patients” had a significantly greater rate of MS patients seen per week. In separate analyses of the “other neurologists” group, the rate of MS patients seen was lower among neurologists in university-based groups or those practicing in major cities; female neurologists; and neurologists who indicated lack of sufficient knowledge regarding MS patient care. Rates of MS patients seen were significantly greater for other neurologists who agreed that MS care involved “ability to improve patient outcomes and quality of life”; “dynamic area with evolving treatment options”; and “enjoy interacting with MS patients.” Understanding factors influencing MS patient care by neurologists and developing policies for appropriate access to care is critical for optimal outcomes among this population. PMID:24949203

  15. Factors Associated with Neurologists’ Provision of MS Patient Care

    Directory of Open Access Journals (Sweden)

    Michael T. Halpern

    2014-01-01

    Full Text Available Neurologists are central to providing quality care for individuals with MS. However, neurologist shortages may restrict access to care for MS patients. To examine factors influencing neurologists’ provision of MS care, we surveyed 1,700 US neurologists to assess demographic/practice characteristics, training, and attitudes toward MS care. The study population consisted of 573 respondents: 87 (15.2% MS subspecialists and 486 (84.8% “other neurologists,” including subspecialists in other neurology areas (i.e., non-MS and general neurologists. MS subspecialists indicating they “enjoy interacting with MS patients” had a significantly greater rate of MS patients seen per week. In separate analyses of the “other neurologists” group, the rate of MS patients seen was lower among neurologists in university-based groups or those practicing in major cities; female neurologists; and neurologists who indicated lack of sufficient knowledge regarding MS patient care. Rates of MS patients seen were significantly greater for other neurologists who agreed that MS care involved “ability to improve patient outcomes and quality of life”; “dynamic area with evolving treatment options”; and “enjoy interacting with MS patients.” Understanding factors influencing MS patient care by neurologists and developing policies for appropriate access to care is critical for optimal outcomes among this population.

  16. What Is in Your Wallet? Quantitation of Drugs of Abuse on Paper Currency with a Rapid LC-MS/MS Method

    Science.gov (United States)

    Parker, Patrick D.; Beers, Brandon; Vergne, Matthew J.

    2017-01-01

    Laboratory experiments were developed to introduce students to the quantitation of drugs of abuse by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Undergraduate students were introduced to internal standard quantitation and the LC-MS/MS method optimization for cocaine. Cocaine extracted from paper currency was…

  17. Deficits in memory and visuospatial learning correlate with regional hippocampal atrophy in MS.

    Science.gov (United States)

    Longoni, Giulia; Rocca, Maria A; Pagani, Elisabetta; Riccitelli, Gianna C; Colombo, Bruno; Rodegher, Mariaemma; Falini, Andrea; Comi, Giancarlo; Filippi, Massimo

    2015-01-01

    The hippocampus has a critical role in episodic memory and visuospatial learning and consolidation. We assessed the patterns of whole and regional hippocampal atrophy in a large group of multiple sclerosis (MS) patients, and their correlations with neuropsychological impairment. From 103 MS patients and 28 healthy controls (HC), brain dual-echo and high-resolution 3D T1-weighted images were acquired using a 3.0-Tesla scanner. All patients underwent a neuropsychological assessment of hippocampal-related cognitive functions, including Paired Associate Word Learning, Short Story, delayed recall of Rey-Osterrieth Complex Figure and Paced Auditory Serial Attention tests. The hippocampi were manually segmented and volumes derived. Regional atrophy distribution was assessed using a radial mapping analysis. Correlations between hippocampal atrophy and clinical, neuropsychological and MRI metrics were also evaluated. Hippocampal volume was reduced in MS patients vs HC (p right and hippocampus). In MS patients, radial atrophy affected CA1 subfield and subiculum of posterior hippocampus, bilaterally. The dentate hilus (DG:H) of the right hippocampal head was also affected. Regional hippocampal atrophy correlated with brain T2 and T1 lesion volumes, while no correlation was found with disability. Damage to the CA1 and subiculum was significantly correlated to the performances at hippocampal-targeted neuropsychological tests. These results show that hippocampal subregions have a different vulnerability to MS-related damage, with a relative sparing of the head of the left hippocampus. The assessment of regional hippocampal atrophy may help explain deficits of specific cognitive functions in MS patients, including memory and visuospatial abilities.

  18. Comparison of piracetam measured with HPLC-DAD, HPLC-ESI-MS, DIP-APCI-MS, and a newly developed and optimized DIP-ESI-MS.

    Science.gov (United States)

    Lenzen, Claudia; Winterfeld, Gottfried A; Schmitz, Oliver J

    2016-06-01

    The direct inlet probe-electrospray ionization (DIP-ESI) presented here was based on the direct inlet probe-atmospheric pressure chemical ionization (DIP-APCI) developed by our group. It was coupled to an ion trap mass spectrometer (MS) for the detection of more polar compounds such as degradation products from pharmaceuticals. First, the position of the ESI tip, the gas and solvent flow rates, as well as the gas temperature were optimized with the help of the statistic program Minitab® 17 and a caffeine standard. The ability to perform quantitative analyses was also tested by using different concentrations of caffeine and camphor. Calibration curves with a quadratic calibration regression of R (2) = 0.9997 and 0.9998 for caffeine and camphor, respectively, were obtained. The limit of detection of 2.5 and 1.7 ng per injection for caffeine and camphor were determined, respectively. Furthermore, a solution of piracetam was used to compare established analytical methods for this drug and its impurities such as HPLC-diode array detector (DAD) and HPLC-ESI-MS with the DIP-APCI and the developed DIP-ESI. With HPLC-DAD and 10 μg piracetam on column, no impurity could be detected. With HPLC-ESI-MS, two impurities (A and B) were identified with only 4.6 μg piracetam on column, while with DIP-ESI, an amount of 1.6 μg piracetam was sufficient. In the case of the DIP-ESI measurements, all detected impurities could be identified by MS/MS studies. Graphical Abstract Scheme of the DIP-ESI principle.

  19. LC-MS-MS aboard ship: tandem mass spectrometry in the search for phycotoxins and novel toxigenic plankton from the North Sea.

    Science.gov (United States)

    Krock, Bernd; Tillmann, Urban; John, Uwe; Cembella, Allan

    2008-11-01

    of plankton from stations with high AZA-1 levels and from the most suspicious size-fraction, i.e. most likely to contain the AZA-producer. A large number (>100) of crude cultures were established by serial dilution and later screened for the presence of AZAs after several weeks growth. From one crude culture containing AZA, a small dinoflagellate was subsequently isolated and brought into pure culture. We have thus proved that even sophisticated mass spectrometers can be operated in ship laboratories without any limitation caused by vibrations of the ship's engine or by wave movement during heavy seas at wind forces up to nine Beaufort. On-board LC-MS-MS is a valuable method for near real-time analysis of phycotoxins in plankton for studies on bloom dynamics and the fate of toxins in the food web, and for characterization and isolation of putatively toxigenic organisms.

  20. Comprehensive comparison of in silico MS/MS fragmentation tools of the CASMI contest: database boosting is needed to achieve 93% accuracy.

    Science.gov (United States)

    Blaženović, Ivana; Kind, Tobias; Torbašinović, Hrvoje; Obrenović, Slobodan; Mehta, Sajjan S; Tsugawa, Hiroshi; Wermuth, Tobias; Schauer, Nicolas; Jahn, Martina; Biedendieck, Rebekka; Jahn, Dieter; Fiehn, Oliver

    2017-05-25

    In mass spectrometry-based untargeted metabolomics, rarely more than 30% of the compounds are identified. Without the true identity of these molecules it is impossible to draw conclusions about the biological mechanisms, pathway relationships and provenance of compounds. The only way at present to address this discrepancy is to use in silico fragmentation software to identify unknown compounds by comparing and ranking theoretical MS/MS fragmentations from target structures to experimental tandem mass spectra (MS/MS). We compared the performance of four publicly available in silico fragmentation algorithms (MetFragCL, CFM-ID, MAGMa+ and MS-FINDER) that participated in the 2016 CASMI challenge. We found that optimizing the use of metadata, weighting factors and the manner of combining different tools eventually defined the ultimate outcomes of each method. We comprehensively analysed how outcomes of different tools could be combined and reached a final success rate of 93% for the training data, and 87% for the challenge data, using a combination of MAGMa+, CFM-ID and compound importance information along with MS/MS matching. Matching MS/MS spectra against the MS/MS libraries without using any in silico tool yielded 60% correct hits, showing that the use of in silico methods is still important.