WorldWideScience

Sample records for krypton-81m blood pool

  1. Continuous determination of regional myocardial blood flow with intracoronary krypton-81m in coronary artery disease

    International Nuclear Information System (INIS)

    Remme, W.J.; Krauss, X.H.; van Hoogenhuyze, D.C.; Cox, P.H.; Storm, C.J.; Kruyssen, D.A.

    1985-01-01

    Pacing-induced changes in regional coronary flow were studied continuously with krypton-81m by intracoronary infusion in 25 patients: 21 with 50% or greater diameter narrowing of 1 or more left coronary arteries (group I) and 4 with less than 50% diameter reduction of a left coronary artery (group II). No changes occurred in group II. In group I, krypton-81m perfusion decreased progressively in all areas with more than 70% diameter narrowing, with a simultaneous increase in normal regions. At the end of pacing during angina, krypton-81m perfusion was reduced to 81 +/- 4% of control in areas with 71 to 90% diameter reduction (n = 8) and to 69 +/- 6% in areas with more than 90% diameter narrowing (n = 15). In contrast, in regions with 50 to 70% diameter reduction changes were variable (decrease in 4 regions, increase in 2 and an unchanged distribution in 1 region). Krypton-81m perfusion decreased early, before general signs of ischemia in areas with more than 90% diameter reduction, whereas this decrease occurred later in regions with 71 to 90% diameter narrowing, concurrently with ST-segment changes but before anginal pain. Although all signs of ischemia had disappeared between 2 and 5 minutes after pacing, changes in krypton-81m distribution persisted in most areas for 5 to 15 minutes after pacing. It is concluded that the functional significance of coronary arterial narrowing can be assessed with a continuous intracoronary infusion of krypton-81m. Changes in regional distribution persisted after cessation of pacing-induced ischemia, indicating an ongoing decrease in regional myocardial blood flow

  2. Ventilation studies of the lung with krypton-81m

    International Nuclear Information System (INIS)

    Klopper, J.F.; Baard, W.P.; Van Heerden, P.D.R.

    1981-01-01

    During a 2-year study period it was found that krypton-81m was useful in clinical practice. During this period 1563 technetium-99m perfusion studies and 807 krypton-81m ventilation studies were performed. A distinct advantage of krypton-81m was the ease with which multiple views could be obtained. These views could be directly compared with those of preceding perfusion studies. However, interruptions in the regular supply of rubidium-81/krypton-81m generators affected 17,1% of perfusion studies and xenon-127 should be a suitable substitute for these periods

  3. Report of the krypton club: availability of sup(81m)krypton in europe

    International Nuclear Information System (INIS)

    Clark, J.; Watson, I.

    1982-01-01

    An active group of producers of krypton 81m generators has been formed. They met in Liege 27th February 1981 to discuss the technical and logistics problems in making krypton 81m generators more widely available in Europe. A resume of that meeting was prepared and distributed at two major medicine meetings in 1981, Pisa and Berne, in an attempt to alert potential users to the current situation and encourage them to make contact with the production centre most favourably situated logistically. (Author)

  4. The evaluation of right ventricular performance using krypton-81m multiple-gated equilibrium cardiac blood pool scintigraphy

    International Nuclear Information System (INIS)

    Hosoi, Tsutomu

    1993-01-01

    Technetium-99m first pass angiography and multiple-gated equilibrium blood pool scintigraphy have been used for evaluating right ventricular performance, but both techniques have several methodologic limitations. The activity of kr-81m is exhaled during its transit through the lungs and residual activity in the left heart is negligible. Therefore, right heart study can be performed in the right anterior oblique position with optimal separation between the right ventricle and the right atrium. Thus, the author assessed right ventricular function using Kr-81m multiple-gated equilibrium cardiac blood pool scintigraphy in 40 patients with old myocardial infarction and 9 normal subjects. The patient group included 11 cases of inferior infarction with a significant stenosing lesion proximal to the origin of the right ventricular branch of the right coronary artery (group I), 11 cases of inferior infarction without a significant lesion in the proximal portion of the right coronary artery (group II) and 18 cases of anterior wall infarction (group III). The right ventricular ejection fraction (EF) was 45.6±9.8% in group I, 56.6±5.7% in group II, 55.6±4.4% in group III and 53.7±3.2% in the 9 normal subjects. There were no statistically significant differences among these 4 groups. However, right ventricular EF was significantly reduced in 5 group I patients who had hemodynamic evidence of right ventricular infarction (39.4±9.5%, P<0.01 vs group II, group III and normal subjects). No significant correlation was found between right and left ventricular EF or between right ventricular EF and wall motion abnormality of the interventricular septum. (author)

  5. Selective scanning of the right ventricle with the ultrashort-lived isotope krypton-81m

    International Nuclear Information System (INIS)

    Horn, M.; Witztum, K.; Neveu, C.; Perkins, G.

    1985-01-01

    The measurement of right ventricular function using /sup 99m/Tc gated blood-pool imaging is hampered by the difficulty in separating the right ventricle from the left heart as well as from the right atrium. Krypton-81m, an ultrashort-lived isotope (t/sub 1/2/, 13 sec) with a single 190-keV gamma ray, can be infused into the venous circulation to yield stable count rates over the right heart. The authors have developed a technique for delivering a continuous infusion of /sup 81m/Kr via an antecubital vein for gated right ventricle (RV) equilibrium studies. Preliminary rest studies have been performed in 15 normal subjects ranging in age from 23 to 62 years. Right-heart structures including the right atrium, tricuspid valve, right ventricle, pulmonic valve, and pulmonary outflow tract are clearly identifiable. Essentially no counts are present over the left heart. RV ejection fractions in this group averaged 48.3 (+/- 5.7)%. Changes in pulmonary blood flow distribution from supine to upright position, which may be an index of pulmonary arterial pressures, are also easily demonstrated

  6. Pulmonary ventilation imaging and function studies with krypton-81m

    International Nuclear Information System (INIS)

    Kaplan, E.; Mayron, L.W.; Gergans, G.A.; Friedman, A.M.; Gindler, J.E.

    1976-01-01

    Chronic obstructive lung disease is a significant entity throughout the world. It is etiologically related to smoking, air pollution and mining. To arrest asymptomatic disease, early diagnosis is required, implying an efficacious, reliable and available methodology, which has the potential for screening suspect populations. Krypton-81m is a 13-second radionuclide that emits a 190 keV gamma ray; it may be produced from a rubidium-81-krypton-81m generator and delivery system, devised, produced and evaluated by the authors. The generator effluent, in gaseous form, may be continually inhaled by a subject while static equilibrium images and dynamic studies of ventilation are produced with a gamma scintillation camera system. The wash-in of /sup 81m/Kr produces heterogeneous images, the activity being proportional to regional ventilation due to rapid decay. Minimal ventilatory delays are detectable. Normal subjects and patients with obstructive lung disease have been evaluated by static equilibrium and dynamic studies. The sensitivity of /sup 81m/Kr studies is currently being compared with various other pulmonary function tests, to evaluate its potential as an appropriate screening technique

  7. Clinical use of ultrashort-lived radionuclide krypton-81m for noninvasive analysis of right ventricular performance in normal subjects and patients with right ventricular dysfunction

    International Nuclear Information System (INIS)

    Nienaber, C.A.; Spielmann, R.P.; Wasmus, G.; Mathey, D.G.; Montz, R.; Bleifeld, W.H.

    1985-01-01

    The ultrashort-lived radionuclide krypton-81m, eluted in 5% dextrose from a bedside rubidium-81m generator, was intravenously infused for rapid imaging of the right-sided heart chambers in the right anterior oblique projection adjusted for optimal right atrioventricular separation. Left-sided heart and lung background was minimized by rapid decay and efficient exhalation of krypton-81m, requiring no algorithm for background correction. A double region of interest method decreased the variability in the assessment of ejection fraction to 5%. In 10 normal subjects, 11 patients with pulmonary hypertension, 4 patients with right ventricular outflow tract obstruction and 4 patients with right ventricular infarction, right ventricular ejection fraction determined by krypton-81m equilibrium blood pool imaging ranged from 14 to 76%. The correlation between these values and those determined by cineangiography according to Simpson's rule was close: r . 0.93 for all data points, r . 0.92 for studies at rest and r . 0.93 for exercise studies. Exercise-related changes in right ventricular function revealed a disturbed functional reserve with pulmonary hypertension and right ventricular infarction, whereas in compensated right ventricular outflow tract obstruction there was a physiologic increase in ejection fraction with exercise. Thus, equilibrium-gated right ventricular imaging using ultrashort-lived krypton-81m is a simple, accurate and reproducible method with potential for serial assessment of right ventricular ejection fraction in a variety of right ventricular anatomic and functional abnormalities, both at rest and during exercise. Advantages of this method include an extremely low radiation dose to patients and clear right atrioventricular separation without the need to correct for background activity

  8. Krypton-81m imaging of the right ventricle

    International Nuclear Information System (INIS)

    Horn, M.; Wiztum, K.; Neveu, C.; Perkins, G.; Walsh, B.

    1985-01-01

    The authors report the development of a method for obtaining right-ventricular radionuclide angiograms using continuous peripheral intravenous infusion of the ultra-short-lived nuclide krypton-81m. This tracer has a half-life of 13 sec, emits a single 190-keV photon, and is extremely insoluble. During infusion into a peripheral vein, Kr-81m achieves stable count rates over the right heart, and it is essentially completely cleared by the lungs during its initial pulmonary transit. Thus no interfering activity is present in the systemic circulation. Initial studies provide excellent data on right-heart anatomy and function

  9. Purification of cyclotron-produced 81Rb for the preparation of small krypton-81m generators

    International Nuclear Information System (INIS)

    Andersen, P.; Haasbroek, F.J.; Venter, S.S.J.; Strelow, F.W.E.

    1981-01-01

    A method is described for the separation of 81 Rb from sodium bromide targets. Ammonium molybdophosphate columns are used and the separation takes only about 20 minutes. More than 90% of the 81 Rb is recovered. The purified 81 Rb enables small Rubidium-81/Krypton-81m generators to be prepared with Bio-Rad 50W-X8 ion-exchange resin (200-400 mesh) [af

  10. The place of krypton-81m ventilation in the scintigraphic investigation of the lung

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Marcuse, H.R.

    1983-01-01

    Fairly recently krypton-81m gas became available for diagnostic purposes. Its advantages and ways to use are surveyed especially for the diagnosis of lung emboli and lung diseases. The combination of perfusion and ventilation scintigrams is the best for specifying the diagnosis. Krypton-81m gas improves the specificity and sensitivity of the examination which is non-invasive and carries no burden for the patient. (Auth.)

  11. Krypton-81 dating of old groundwater. Chapter 5

    International Nuclear Information System (INIS)

    Purtschert, R.; Yokochi, R.; Sturchio, N.C.

    2013-01-01

    The abundance of krypton in the atmosphere has been quoted for nearly half a century as 1.14 ± 0.01 ppm, which corresponds to a total atmospheric inventory of 4.51 × 10 12 m 3 STP (Verniani (1966) [243]). A recent re-evaluation yielded a value of 1.099 ± 0.009 ppmv, which is about 4% lower than the previously used value (Aoki and M akide (2005) [244]). Krypton has six stable isotopes of which 84 Kr is the most abundant, comprising about 57% of natural Kr (Table 5.1). Eleven major radioactive isotopes of Krexist but only 81 Kr and 85 Kr, with halflives of 229 000 and 10.76 a, respectively, exceed 2 d and are, therefore, suitable for the investigation of environmental processes. Krypton-81 is produced in the atmosphere by cosmic ray induced spallation of heavier stable Krisotopes and by the nuclear reactions 80 Kr(n, γ) 81 Kr and 82 Kr(γ, n) 81 Kr.

  12. The evaluation of right ventricular performance using krypton-81m

    International Nuclear Information System (INIS)

    Ham, H.R.; Piepsz, A.; Vandevivere, J.; Guillaume, M.; Goethals, P.; Lenaers, A.

    1983-01-01

    The availability of krypton-81m suitable for intravenous injection provides an easy means for assessing right ventricular function. The superimposition of the other heart chambers does not constitute a problem. The activity in the left heart is negligible and the study can be performed in the right anterior oblique position to obtain optimal separation between the right atrium and the right ventricle. Lung activity is quite high and should be corrected before computing the right ventricular ejection fraction. This correction can be accomplished by performing Tc-99m MAA perfusion scintigraphy. The measurement of the right ventricular ejection fraction appears to be reproducible with very small inter-and intraobserver variability. Good quality phase and amplitude images can be obtained with such high count rates

  13. Analysis of krypton-85 and krypton-81 in a few liters of air.

    Science.gov (United States)

    Tu, Le-Yi; Yang, Guo-Min; Cheng, Cun-Feng; Liu, Gu-Liang; Zhang, Xiang-Yang; Hu, Shui-Ming

    2014-04-15

    Long-lived radioactive krypton isotopes, (81)Kr (t1/2 = 229,000 year) and (85)Kr (t1/2 = 10.76 year), are ideal tracers. (81)Kr is cosmogenic and can be used for dating groundwater beyond the (14)C age. (85)Kr is a fission product and can be applied in atmospheric studies, nuclear safety inspections, and dating young groundwater. It has long been a challenge to analyze radio-krypton in small samples, in which the total number of such isotopes can be as low as 1 × 10(5). This work presents a system developed to analyze (81)Kr and (85)Kr from a few liters of air samples. A separation system based on cryogenic distillation and gas chromatographic separation is used to extract krypton gas with an efficiency of over 90% from air samples of 1-50 L. (85)Kr/Kr and (81)Kr/Kr ratios in krypton gases are determined from single-atom counting using a laser-based atom trap. In order to test the performance of the system, we have analyzed various samples collected from ambient air and extracted from groundwater, with a minimum size of 1 L. The system can be applied to analyze (81)Kr and (85)Kr in environmental samples including air, groundwater, and ices.

  14. Radiation protection problems in using krypton 81 m in pulmonary ventilation scintiscanning

    International Nuclear Information System (INIS)

    Spesshardt, K.

    1982-01-01

    The experience gained in using the krypton-81 generator as regards radiation protection is briefly outlined by means of measurements, carried through in the framework of the operation licensing procedure. It turned out that while krypton is a very helpful substance in clinical investigations on account of its favourable gamma energy and very short half-life, it does create some radiation protection problems. The radiation protection measures carried through at the inhalation system can be described as satisfactory. Improvements are due at the filter system between generator and breathing mask. (orig./DG) [de

  15. Pulmonary dynamics and functional imaging with krypton-81m as related to generator delivery characteristics

    International Nuclear Information System (INIS)

    Kaplan, E.

    1985-01-01

    Krypton-81m supplied from a generator by continuous elution with air is used with a gamma-camera computer system to produce a sequence of images from multiple breaths, which reconstructed the time-activity images of the breathing human lung. Functional images are produced by subsequent derivation to show specific variables of the dynamic sequences. The dynamic, quantitative, and regional aspects of the respiratory cycle are thus made available in a single study. The need for the delivery of a constant ratio of /sub 81m/Kr to air is required to accurately produce these various studies

  16. Krypton 81m and xenon 133 for complementary ventilation imaging in pulmonary perfusion studies: a clinical comparison. Chapter 12

    International Nuclear Information System (INIS)

    Weber, P.M.; Remedios, L.V.dos.

    1978-01-01

    Twenty-four patients with suspected pulmonary embolism were studied to determine the relative usefulness of 133 Xe and 81 Krsup(m) as indicators of pulmonary ventilation in complementing perfusion studies. In most cases, where krypton produced results superior to xenon, this could be attributed to better resolution of the 190 keV photon and to the fact that multiple views could be obtained, with each view paired precisely with a corresponding perfusion image, the direct result of the ease of use of krypton and its short 13 second half-life. This was well demonstrated in both of the patients with presumed pulmonary embolism and co-existing other pulmonary disease in which the results with xenon and krypton differed. In each case the mis-match was obscured by closely related areas of delayed xenon wash-out. In those patients where xenon demonstrated greater sensitivity in identifying areas of pulmonary disease, the lesions noted on wash-out appeared as areas of positive activity, while with krypton the defects were always photogenic and, when small probably obscured by scatter from adjacent normal activity. In the patient who might have been improperly categorized as a mis-match without the krypton study, the xenon study may have been normal because of inadequate equilibration time. (author)

  17. Krypton 81m infusion studies. Chapter 18

    International Nuclear Information System (INIS)

    Kaplan, E.; Mayron, L.W.; Friedman, A.M.; Gindler, J.E.

    1978-01-01

    A technique is described to give a continuous, constant-rate, intravascular infusion of 81 Krsup(m). Modifications of earlier generators included production of sodium-free 81 Rb, the use of a solution of commercial sterile isotonic non-ionic 5% dextrose-in-water as an eluant, the incorporation of a constant-rate infusion pump, and the miniaturization of the generator column and catheter system. Results are presented of studies of 81 Krsup(m) distribution in dogs, using both intravenous and intra-arterial infusion. (author)

  18. [sup 99]Tc[sup m]-Technegas and krypton-81 m ventilation scintigraphy: a comparison in known respiratory disease

    Energy Technology Data Exchange (ETDEWEB)

    James, J.M.; Lloyd, J.J.; Leahy, B.C.; Church, S.; Hardy, C.C.; Shields, R.A.; Prescott, M.C.; Testa, H.J. (Royal Infirmary, Manchester (United Kingdom))

    1992-12-01

    The new radiopharmaceutical [sup 99]Tc[sup m]-Technegas, a suspension of ultrafine technetium-99m labelled carbon particles, produces high-quality images of ventilation and has the advantage of continuous availability. Technegas was compared with krypton-81m gas in 40 patients with a variety of established respiratory diseases. Disparities were seen in five patients in five diagnostic groups and may be a consequence of differing physical properties of the two agents and the different inhalation techniques used. In addition, on the Technegas images, (1) Hot spots were seen in 50% of patients, particularly in those with a degree of airways obstruction; (2) preferential basal deposition of activity was seen in 30%, particularly in patients with idiopathic pulmonary fibrosis. Both features were significantly associated with parameters of pulmonary function indicating obstructive lung disease in the former case and restrictive lung disease in the latter. (author).

  19. 99Tcm-Technegas and krypton-81 m ventilation scintigraphy: a comparison in known respiratory disease

    International Nuclear Information System (INIS)

    James, J.M.; Lloyd, J.J.; Leahy, B.C.; Church, S.; Hardy, C.C.; Shields, R.A.; Prescott, M.C.; Testa, H.J.

    1992-01-01

    The new radiopharmaceutical 99 Tc m -Technegas, a suspension of ultrafine technetium-99m labelled carbon particles, produces high-quality images of ventilation and has the advantage of continuous availability. Technegas was compared with krypton-81m gas in 40 patients with a variety of established respiratory diseases. Disparities were seen in five patients in five diagnostic groups and may be a consequence of differing physical properties of the two agents and the different inhalation techniques used. In addition, on the Technegas images, (1) Hot spots were seen in 50% of patients, particularly in those with a degree of airways obstruction; (2) preferential basal deposition of activity was seen in 30%, particularly in patients with idiopathic pulmonary fibrosis. Both features were significantly associated with parameters of pulmonary function indicating obstructive lung disease in the former case and restrictive lung disease in the latter. (author)

  20. Applications and interpretation of krypton 81m ventilation/technetium 99m macroaggregate perfusion lung scanning in childhood

    Science.gov (United States)

    Davies, Hugh Trevor Frimston

    Radionuclide ventilation perfusion lung scans now play an important part in the investigation of paediatric lung disease, providing a safe, noninvasive assessment of regional lung function in children with suspected pulmonary disease. In paediatric practice the most suitable radionuclides are Krypton 81m (Kr81m) and Technetium 99m (Tc99m), which are jointly used in the Kr81m ventilation/Tc99m macroaggregate perfusion lung scan (V/Q lung scan). The Kr81m ventilation scan involves a low radiation dose, requires little or no subject cooperation and because of the very short half life of Kr81m (13 seconds) the steady state image acquired during continuous inhalation of the radionuclide is considered to reflect regional distribution of ventilation. It is now the most important noninvasive method available for the investigation of the regional abnormalities of ventilation characteristic of many congenital and acquired paediatric respiratory diseases, such as diaphragmatic hernia, pulmonary sequestration, bronchopulmonary dysplasia, foreign body inhalation and bronchiectasis. It improves diagnostic accuracy, aids clinical decision making and is used to monitor the progress of disease and response to therapy. Theoretical analysis of the steady state Kr81m ventilation image suggests that it may only reflect regional ventilation when specific ventilation (ventilation per unit volume of lung) is within or below the normal adult range (1-3 L/L/min). At higher values such as those seen in neonates and infants (8-15 L/L/min) Kr81m activity may reflect regional lung volume rather than ventilation, a conclusion supported by the studies of Ciofetta et al. There is some controversy on this issue as animal studies have demonstrated that the Kr81m image reflects ventilation over a much wider range of specific ventilation (up to 13 L/L/min). A clinical study of sick infants and very young children is in agreement with this animal work and suggests that the steady state Kr81m image

  1. An experimental investigation of proton-induced phenomena in krypton

    International Nuclear Information System (INIS)

    Mulders, J.J.L.

    1985-01-01

    In this thesis proton-induced phenomena in krypton gas are described. The considered reactions of protons on krypton are both nuclear and atomic. The nuclear conversion processes mainly result in the production of several Rb radioisotopes, such as 81 Rb that is used in 81 Rb-sup(81m)Kr generator systems for medical diagnostics. The irradiation of krypton gas (natural composition) with protons of about 26 MeV can be used for the routine production of 81 Rb from the direct production reaction 82 Kr(p,2n) 81 Rb and from the indirect reaction 82 Kr(p,2n)sup(81m)Rb → 81 Rb. To determine the scattering of protons in krypton gas targets a quantitative autoradiographic technique was developed. Proton profiles have been determined from the proton-induced activity distribution on a copper foil. For the on-line detection of produced Rb radioisotopes several optical detection techniques were investigated. (Auth.)

  2. Evaluation of hepatic hemangioma by Tc-99 m red blood cell hepatic blood pool scan

    International Nuclear Information System (INIS)

    Sohn, Myung Hee

    2005-01-01

    Hemangioma is the most common benign tumor of the liver, with a prevalence estimated as high as 7%. Tc-99m red blood cell (RBC) hepatic blood pool scan with single photon emission computed tomography (SPECT) imaging is extremely useful for the confirmation or exclusion of hepatic hemangiomas. The classic finding of absent or decreased perfusion and increased blood pooling ('perfusion/blood pool mismatch') is the key diagnostic element in the diagnosis of hemangiomas. The combination of early arterial flow and delayed blood pooling ('perfusion/blood pool match') is shown uncommonly. In giant hemangioma, filling with radioactivity appears first in the periphery, with progressive central fill-in on sequential RBC blood pool scan. However, the reverse filling pattern, which begins first in the center with progressive peripheral filling, is also rarely seen. Studies with false-positive blood pooling have been reported infrequently in nonhemangiomas, including hemangiosarcoma, hepatocellular carcinoma, hepatic adenoma, and metastatic carcinomas (adenocarcinma of the colon, small cell carcinoma of the lung, neruroendocrine carcinoma). False-negative results have been also reported rarely except for small hemagniomas that are below the limits of spatial resolution of gamma camera

  3. Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo and with technetium-99m human serum albumin

    International Nuclear Information System (INIS)

    Thrall, J.H.; Freitas, J.E.; Swanson, D.; Rogers, W.L.; Clare, J.M.; Brown, M.L.; Pitt, B.

    1978-01-01

    Technetium-99m red blood cells (Tc-RBC) labeled by an in vivo technique were compared with two preparations of Tc-99m human serum albumin (HSA) for cardiac blood-pool imaging. Relative distribution of the tracers was analyzed on end-diastolic frames of gated blood-pool studies and on whole-body (head to mid-thigh) anterior pinhole images. The Tc-RBC demonstrated greater relative percentage localization in the cardiac blood pool, higher target-to-background ratios in the left ventricle, and less liver concentration. For cardiac blood-pool imaging, Tc-RBC labeled by the in vivo approach appears to be superior to the two Tc-HSA preparations studied

  4. /sup 99m/Tc dextran: a new blood-pool-labeling agent for radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Henze, E.; Robinson, G.D.; Kuhl, D.E.; Schelbert, H.R.

    1982-01-01

    We have explored the possibility of imaging the cardiac blood pool with dextran (Dx) labeled with /sup 99m/Tc (Tc) after Sn2+ reduction. Stannous dextran (SnDx) kits were prepared in advance and labeling was performed by adding /sup 99m/Tc. The labeling efficiency was greater than 95%. /sup 99m/Tc dextran (TcDx) was highly stable both in vivo and in vitro. In seven dogs we compared the quality of blood-pool images obtained with TcDx of different molecular weights (4 X 10(4) . Dx-40; 5 X 10(5) . Dx-500; 2 X 10(6) . Dx-2000) and with /sup 99m/Tc red blood cells (TcRBC) labeled in vitro, and determined the organ distribution of this new agent by whole-body scanning and blood sampling. TcDx provided high-quality cardiac blood-pool images up to 60 min after injection. The heart-to-lung ratios averaged 3.7 for TcDx-40, 3.9 for TcDx-500, and 5.4 for TcRBC at 60 min. Whereas TcDx-40 showed a relatively rapid initial urinary excretion and TcDx-2000 was degraded rapidly, TcDx-500 demonstrated the best kinetics for blood-pool imaging. Thus, TcDx is a new radiopharmaceutical with high labeling efficiency and stability. It overcomes a number of the limitations of currently used blood-labeling agents and may become useful for blood-pool imaging in man

  5. Development of a nickel plated aluminum krypton-81m target system.

    Science.gov (United States)

    Alrumayan, F; Okarvi, S M; Nagatsu, K; Yanbawi, S; Aljammaz, I

    2017-03-01

    A fully automated system was developed to produce rubidium-81 ( 81 Rb), based on the nat Kr (p, n) 81 Rb reaction. The energy incident on the target was 26MeV. Only 6MeV was stopped inside the gas and the remainder was stopped by a specially designed flange. The target body was characterized by its conical shape and its inner walls were chemically plated with 100±10µm of nickel (Ni). Ni is advantageous as a fairly good conductor of heat whose surface can resist solutions. Additionally, the Ni plated target allowed potassium chloride to dissolve 81 Rb, with no further effect on the target body. The system produced 81 Rb with a production yield of approximately 4.5mCi/µAh, which is close to the calculated expected yield of 5.3mCi/µAh. The system is able to deliver reliable and reproducible radioactivity for patients and can be operated up to 1500µAh before preventive maintenance is due. Key steps in designing the 81 Rb target for selected energy ranges are reported here. Copyright © 2016. Published by Elsevier Ltd.

  6. Production of 81Rb/sup 81m/Kr generators with 60-MeV protons at BLIP

    International Nuclear Information System (INIS)

    Mausner, L.F.; Richards, P.

    1983-01-01

    By bombarding natural krypton gas with approx. 63 MeV protons, 81 Rb is formed by (p,4n) reaction from high abundance 84 Kr (57%) as well as some additional contribution from 83 Kr (11.5%) and 82 Kr (11.6%) by (p,3n) and (p,2n) reactions, respectively. The production rate of 81 Rb is typically 1.5 mCi/μAh. This production rate is sufficient to create up to several hundred millicuries per run if necessary, enough for several high activity 81 Rb/sup 81m/Kr generators. Presently generators that deliver 10 to 20 mCi to the lungs are produced weekly for on-site use. The only other important activity in the solution is Rb-82m (6.4 hr). Small amounts of Br-76 (16.1 hr), Br-77 (57 hr), Br-82 (35.5 hr), Rb-83 (86.2 d), and Rb-84 (33 d) were also present. The bromine impurities pose no problem since they are not trapped on the generator. Rb-82m and Rb-84 decay to stable Kr-82 and Kr-84 in the generator and do not interfere with Kr-81m studies

  7. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy.

    Science.gov (United States)

    Cowley, M J; Mantle, J A; Rogers, W J; Russell, R O; Rackley, C E; Logic, J R

    1979-06-01

    It has been suggested that diffuse Tc-99m pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60--90 min following the injection of 12--15 mCi of Tc-99m pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to "rule out" infarction 24--72 hr after onset of suggestive symptoms.

  8. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Cowley, M.J.; Mantle, J.A.; Rogers, W.J.; Russell, R.O. Jr.; Rackley, C.E.; Logic, J.R.

    1979-01-01

    It has been suggested that diffuse 99m Tc pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60 to 90 min following the injection of 12 to 15 mCi of 99m Tc pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to rule out infarction 24 to 72 hr after onset of suggestive symptoms

  9. [Effects of xenon and krypton-containing breathing mixtures on clinical and biochemical blood indices in animals].

    Science.gov (United States)

    Kussmaul', A R; Bogacheva, M A; Shkurat, T P; Pavlov, B N

    2007-01-01

    Effects of 24-hr breathing air mixtures containing xenon (XBM) and krypton (KBM) were compared in terms of hormonal status, and blood biochemical indices and morphology in laboratory animals. Some changes observed in blood and hormone indices could be a nonspecific adaptive response. Hence, we should elicit whether these effects are quickly reversible or long. For several indices krypton was a more favorable factor than xenon. However, some of its effects invite to delve into effects of different krypton concentrations on organism.

  10. Kripton-81m generator for ventilation and perfusion

    International Nuclear Information System (INIS)

    Guillaume, M.; Czichosz, R.; Richard, P.; Fagard, E.

    1983-01-01

    This paper summarizes the results of research carried out over the last few years at the Cyclotron Research Center, Liege University, towards the development of a krypton 81m generator for clinical use. This study has presented many aspects: its primary concern is optimum production conditions using a compact cyclotron to produce a generator compatible with routine production as well as the supply reliability necessary for clinical experimentation. This resulted in setting up a completely automatic, microprocessor run production station. It defines the most efficient working conditions, and consequently exploitation conditions, due to the knowledge of the daughter element's extraction mechanisms in gas and liquid phases. It proposes different methods to evaluate the generator's fundamental characteristics and to standardize its different clinical uses. The qualitative and quantitative evaluation of all radionuclide species produced simultaneously to the 81 Rb precursor constitutes a new advance in radiopharmaceutical quality control. The problem of sup(81m) Kr dosimetry admistered in liquid or gas phase has been reviewed on the basis of reproducible, optimised experimental results from the latest literature

  11. The production of *sp81m*Kr generators at the Oslo cyclotron

    International Nuclear Information System (INIS)

    Bjroenstad, T.; Holtebekk, T.; Ruud, A.

    1984-01-01

    The techniques developed for the production of *sp81m*Kr(13s) ventilation generators at the Oslo cyclotron are described. The procedure is based on the reaction *sp82*Kr(p,2n)*sp81*Rb using krypton gas of natural composition as target. The target chamber is designed for a gas pressure of 10 bar. The production unit is dimensioned for a parallel production of five generators, but this number may easily be increased. Attention is drawn to the fact that *sp81m*Rb(31 min) is produced in about the same amount as the *sp81*Rb (4.57 h) ground state. The consequences for the calibration procedure is discussed. Routine production has been exerted without major difficulties for nearly 1.5 years. The procedure has proven to be inexpensive and reliable. (Auth.)

  12. Pulmonary ventilation studies of asthmatic children with Kr-81m

    International Nuclear Information System (INIS)

    Uchiyama, Guio; Hotta, Toshiko; Arimizu, Noboru; Sugimoto, Kazuo.

    1979-01-01

    Krypton-81 m gas was eluted from the 81 Rb-sup(81m)Kr generator by using compressed air or oxygen as an eluting agent. The continuous inhalation of mixed gas of sup(81m)Kr and air or oxygen with the use of a scintillation camera produced a pulmonary image of which density was proportional to regional ventilation. Because of short half life of sup(81m)Kr (13 seconds), exhaled gas was not necessary to be trapped by the charcoal filter, and the several pulmonary views of a patient could readily be available in a short period of time. The great advantage of sup(81m)Kr generator was found in use for the studies of small children who were not usually cooperative to medical examination. Thirty seven patients with bronchial asthma of any state were so far studied. Their ages ranged from 3 to 15 years old. Studies revealed the definite ventilation defects in scans of patients with asthmatic attack. Re-scans right after the use of bronchodilators showed marked improvement of the ventilation defects. Exercise-induced asthma (EIA) was easily identified by the sup(81m)Kr ventilation study. After premedications for EIA with disodium cromoglicate, the next exercises produced less or no ventilation defects, and the preventive effect could be individually examined. The sup(81m)Kr ventilation study was also used for estimating the patient's sensitivity to provokative substances of bronchial asthma. House dust was continuously inhaled with sup(81m)Kr gas by patients. The threshold dose of house dust of disclosing ventilation defects in scans was definitely less than that of provokating the symptom of asthmatic attack. The sensitive sup(81m)Kr ventilation study could be another provokative test which induces no clinical symptoms. (author)

  13. Pulmonary ventilation studies of asthmatic children with Kr-81m

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, G; Hotta, T; Arimizu, N [Chiba Univ. (Japan). School of Medicine; Sugimoto, K

    1979-05-01

    Krypton-81 m gas was eluted from the /sup 81/Rb-sup(81m)Kr generator by using compressed air or oxygen as an eluting agent. The continuous inhalation of mixed gas of sup(81m)Kr and air or oxygen with the use of a scintillation camera produced a pulmonary image of which density was proportional to regional ventilation. Because of short half life of sup(81m)Kr (13 seconds), exhaled gas was not necessary to be trapped by the charcoal filter, and the several pulmonary views of a patient could readily be available in a short period of time. The great advantage of sup(81m)Kr generator was found in use for the studies of small children who were not usually cooperative to medical examination. Thirty seven patients with bronchial asthma of any state were so far studied. Their ages ranged from 3 to 15 years old. Studies revealed the definite ventilation defects in scans of patients with asthmatic attack. Re-scans right after the use of bronchodilators showed marked improvement of the ventilation defects. Exercise-induced asthma (EIA) was easily identified by the sup(81m)Kr ventilation study. After premedications for EIA with disodium cromoglicate, the next exercises produced less or no ventilation defects, and the preventive effect could be individually examined. The sup(81m)Kr ventilation study was also used for estimating the patient's sensitivity to provokative substances of bronchial asthma. House dust was continuously inhaled with sup(81m)Kr gas by patients. The threshold dose of house dust of disclosing ventilation defects in scans was definitely less than that of provokating the symptom of asthmatic attack. The sensitive sup(81m)Kr ventilation study could be another provokative test which induces no clinical symptoms. (author).

  14. Development of Tc-99m-DTPA-HSA as a new blood pool scanning agent

    Energy Technology Data Exchange (ETDEWEB)

    Shirakami, Y; Matsumoto, Y; Yamauchi, Y; Kurami, M; Ueda, N; Hazue, M

    1987-04-01

    A new HSA preparation, Tc-99m-DTPA-HSA, was developed as a blood pool scanning agent. It shows higher labeling yield (more than 95 %) and higher blood retention (74.7 % I.D. at 1 hour post-injection) than Tc-99m-HSA prepared by directly labeling of HSA with Tc-99m. The introduction of DTPA, a strong bifunctional chelating agent, to HSA provides sites for the stable binding of Tc-99m. The preparation composed of 20 mCi of Tc-99m at calibration time and 10 mg of DTPA-HSA in a vial. After labeling, it had been stable for 24 hours at room temperature. In rats, most of Tc-99m-DTPA-HSA injected was metabolized and excreted in urine and feces. The cumulative radioactivity in urine and feces were 56.0 % and 13.7 % of injected dose, respectively, at 48 hours after injection. Metabolites observed in urine were Tc-99m-urea, Tc-99m-DTPA, reduced Tc-99m and so on. Tc-99m-DTPA-HSA proved, thus, a desirable feature for the blood pool scanning agent.

  15. Krypton-85 storage in sputter-deposited amorphous metals

    International Nuclear Information System (INIS)

    Tingey, G.L.; McClanahan, E.D.; Lytle, J.M.; Gordon, N.R.; Knoll, R.W.

    1982-06-01

    After comparing options for storing radioactive krypton gas, the United States Department of Energy selected ion implantation of the gas into a sputter-deposited metal matrix as the reference process. This technique is being developed with pilot-scale testing and further characterization of the deposited product. The process involves implanting krypton atoms into a growing deposit during the sputtering process. An amorphous metal deposit of nominal composition Ni 0 81 La 0 09 Kr 0 10 has been selected for further studies because of the high krypton loading, high sputtering yield, relatively low cost of the metallic components, resistance to corrosion, and stability of the product. The krypton release from this amorphous metal is described as an activated diffusion process which increases linearly with the square root of time. Studies of krypton release rate as a function of temperature were completed and an activation energy for the diffusion of 70 kcal/mole obtained. From these data, we estimated that the krypton release during the first ten years would be 0.5% for a maximum temperature of 350 0 C. The actual release of the krypton during storage was projected to be lower by a factor of 10 7 with the maximum temperature only 220 0 C. Thermal analysis studies show two energy releases occurring with krypton-containing alloys: one associated with recrystallization of the amorphous alloy and a second associated with krypton release. The total energy release between 100 and 800 0 C was less than 50 cal/g. Estimates are given for the cost of operation of the ion implantation process for solidification of the krypton-85 from a 2000-tonne heavy metal/year reprocessing plant. The present value costs, in 1981 dollars including capital and operating costs and assuming a 30-year life, are about $26M for the lifetime of the plant. Annual energy consumption of the process was estimated to be 3.9 M kWh/year

  16. Assessment of right ventricular function and anatomy using peripheral vein infusion of krypton 81m

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; Kamal, S.; Deanfield, J.E.; McKenna, W.J.; Myers, M.J.; Watson, I.A.; Oakley, C.M.; Lavender, J.P. (Royal Postgraduate Medical School, London (UK))

    1983-09-01

    A method for imaging the right side of the heart (atrium, ventricle and main pulmonary artery) and for assessment of RV systolic function (ejection fraction and ejection rate) is described. An ultra-short-lived isotope (/sup 81/Krsup(m)) is continuously eluted in 5% dextrose and infused into an ante-cubital arm vein; standard multigated images are acquired using a gamma camera and commercially available software. Preliminary evaluation of the method in 55 subjects (20 with repaired tetralogy of Fallot, 14 with dilated cardiomyopathy and 21 normal volunteers) showed that the technical success rate was 100%; that RV boundaries free from LV overlap can be clearly visualised due to efficient exhalation of /sup 81/Krsup(m) through the lungs and that /sup 81/Krsup(m) measurements of RVEF are reproducible. The technique offers considerable potential for serial non-invasive assessment of RV function.

  17. Assessment of right ventricular function and anatomy using peripheral vein infusion of krypton 81m

    International Nuclear Information System (INIS)

    Sugrue, D.D.; Kamal, S.; Deanfield, J.E.; McKenna, W.J.; Myers, M.J.; Watson, I.A.; Oakley, C.M.; Lavender, J.P.

    1983-01-01

    A method for imaging the right side of the heart (atrium, ventricle and main pulmonary artery) and for assessment of RV systolic function (ejection fraction and ejection rate) is described. An ultra-short-lived isotope ( 81 Krsup(m)) is continuously eluted in 5% dextrose and infused into an ante-cubital arm vein; standard multigated images are acquired using a gamma camera and commercially available software. Preliminary evaluation of the method in 55 subjects (20 with repaired tetralogy of Fallot, 14 with dilated cardiomyopathy and 21 normal volunteers) showed that the technical success rate was 100%; that RV boundaries free from LV overlap can be clearly visualised due to efficient exhalation of 81 Krsup(m) through the lungs and that 81 Krsup(m) measurements of RVEF are reproducible. The technique offers considerable potential for serial non-invasive assessment of RV function. (author)

  18. Assessment of regional ventilation by continuous inhalation of radioactive krypton-81m.

    Science.gov (United States)

    Fazio, F; Jones, T

    1975-01-01

    A simple technique is described for producing high-quality functional images of regional ventilation during physiological tidal breathing of the inert gas 81mKr. These images are quickly obtained on a gamma-camera without the need of computerized systems for data acquisition and display and are directly comparable with those of perfusion obtained with 99mTc-labelled macroaggregates. The short time required for the procedure, its simplicity, and the extremely low absorbed-radiation dose enable serial images of ventilation to be obtained in multiple views. Images FIG. 2 FIG. 3 FIG. 4 PMID:1182453

  19. Cyclotron production of krypton-77 for regional cerebral blood flow measurement

    International Nuclear Information System (INIS)

    Houdayer, A.J.; Meyer, E.; Yamamoto, Y.L.

    1977-01-01

    Krypton-77 has favourable decay characteristics for use in studies of regional cerebral blood flow, and the gas may be administered by inhalation. A description is given of the preparation and separation of radioactive sources of 77 Kr gas of strength between 1 and 5 mCi. The sources were produced via the reaction 79 Br(p,3n) 77 Kr induced by 30 MeV protons in targets of NaBr powder enriched to 99.75% 79 Br. A simple and rapid separation of the other contaminants produced in the target was achieved by means of cold traps. The fresh product showed no gamma ray spectra other than those of 77 Kr and 79 Kr, and only traces of 79 Kr were present. (U.K.)

  20. Distribution of the blood flow supplied by the vertebral artery in humans as assessed by emission CT

    International Nuclear Information System (INIS)

    Taki, W.; Handa, H.; Higa, T.; Tanada, S.; Fukuyama, H.; Fujita, T.; Yonekawa, Y.; Kameyama, M.; Torizuka, K.

    1984-01-01

    Though unilateral blood distribution of the vertebral artery has not been studied in humans, it is significant when considering the ischemic events especially embolic occlusion in vertebrobasilar system. To clarify the blood distribution, Krypton-81m was continuously infused into the vertebral arteries of 10 patients. Radioactivity was recorded by a rotating gamma camera. The perfusion images, reconstructed by computer in the transaxial plane, were classified according to whether the distribution was equal, or predominantly unilateral. Overlapping of blood supply from each vertebral artery was studied. In addition, the perfusion from one of the vertebral arteries revealed four distribution patterns with respect to laterality. A) ipsilateral; B) contralateral; C) bilateral; D) mosaic. Images obtained following perfusion of the vertebral artery show less uniformity compared to that of the internal carotid artery, suggesting a complicated vascular supply of the vertebral basilar territory. This complex distribution can be classified by the use of continuous infusion of Krypton-81m

  1. Scintigraphic detection of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging

    Energy Technology Data Exchange (ETDEWEB)

    Georgiou, E C; Arkas, A Z; Alevizaki, C C; Gnafakis, N [Evangelismos Hospital, Athens (Greece). Dept. of Endocrinology and Radioisotopes; Evangelismos Hospital, Athens (Greece). Gynaecology Clinic)

    1979-12-01

    Three cases of scintigraphic visualization of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging are presented, i.e. one case of fibrothecoma ('cold' area visualization) and two cases of fibromyoma ('hot' area visualization). It is suggested that this technique may be useful in the preoperative evaluation of gynaecological tumours and their vascularity.

  2. Innovative method for ultra-sensitive measurement of krypton isotopes

    International Nuclear Information System (INIS)

    Lavielle, B.; Gilabert, E.; Thomas, B.; Rebeix, R.; Canchel, G.; Moulin, C.; Topin, S.; Pointurier, F.

    2015-01-01

    Kr 81 (T 1/2 = 2.29*10 5 y), that is produced in the atmosphere by cosmic rays and Kr 85 (T 1/2 = 10.77 y), that is produced in the fission of nuclear fuels, are considered as the right chronometer elements for the dating of underground waters, polar ice, of for tracking civil and military nuclear activities. The use of Kr 81 and Kr 85 implies the development of extracting lines and detection devices with so high accuracy that only a few thousands of krypton atoms can be detected. The approach developed aims at detecting Kr 81 and Kr 85 in 1 liter of air and 20 liters of water. 3 steps are necessary. The first step consists in separating and purifying the krypton. The extraction of gases from water is made by helium bubbling. Chemically active gases like N 2 , CO 2 , CH 4 and O 2 are eliminated by chemical traps while Ar si separated by cryogenics. The second step involves a double focus mass spectrometer designed to perform an important enrichment in Kr 81 and Kr 85 . The last step is the high-accuracy measurement of krypton isotopes performed with the new tool named FAKIR (Facility for Analyzing Krypton Isotopic Ratios) that is based on UV laser ionization and on the mass-discrimination of the ions through their time of flight

  3. Single breath study for lung scan with krypton-81m: proposition of a mathematical model

    International Nuclear Information System (INIS)

    Pommet, R.; Mathieu, E.

    1981-01-01

    A single breath study with sup(81m)Kr was proceeded in patients, and we studied a theorical model. Based on experimental datas, the model was extrapolated by simple compartimental hypothesis, permitting a study per area of the instant alveolar lung flow by a deconvolution operation. An other approach to present the local ventilation is proposed too. Based on the average flow of ventilation index, calculation is obtained easier than by deconvolution method, and this method fully agree with the proposed model. This index allows the realisation of functionnal views of the local ventilation flow, made possible by the use of a computer for the study of each elementary area of the lung and the realisation of the activity curve recorded during the sup(81m)Kr first breath [fr

  4. Evaluation of supine and sitting cardiac blood pool scans with sup(99m)Tc-HSA

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Kuwajima, Akira; Hisada, Kinichi

    1977-01-01

    In the differential diagnosis of enlarged cardiac silhouette on plain chest x-ray film, cardiac blood pool scan was usually performed at first. However, small amount of pericardial effusion was difficult to detect on cardiac blood pool scan and differentiation of pericardial effusion from myocardial thickening was sometimes difficult. We evaluated cardiac blood pool scan with sup(99m)Tc-HSA(human serum albumin) and gamma camera imaged on both supine and sitting position, and evaluated diagnostic efficiency of criteria for pericardial effusion of these scans. Fifty-seven patients suspected of having pericardial effusion were included in the study. Sixteen of these patients had pericardial effusion and 2 of these 16 patients had free pleural effusion. Three patients had pleural effusion alone and excluded from the study. Of the five criteria for pericardial effusion, separation between heart and right lung activities was most frequent in both effusion (true positive, TP=100% on both supine and sitting) and no effusion (false positive, FP=18.4% on supine and 23.7% on sitting) groups. However, increased heart and right lung separation on sitting position was rather frequent in effusion group, and this finding was also thought to be typical for effusion but not for myocardial thickening. Decreased cardiohepatic separation on sitting position was frequent in no effusion group, and FP rate was decreased from 18.4% (supine) to 10.5% (sitting). Two patients with both pericardial effusion and free pleural effusion were easily diagnosed on sitting cardiac blood pool scan. With ROC(receiver operating characteristic) curve, three criteria should be agreed on either supine or sitting scan for diagnosis of pericardial effusion, and six criteria should be agreed when both supine and sitting scans were employed for diagnosis of pericardial effusion. (auth.)

  5. Equilibrium blood pool scanning in the evaluation of hemophilic arthropathy

    International Nuclear Information System (INIS)

    Spies, S.; Green, D.; Rana, N.A.; Milgram, J.W.; Mintzer, R.

    1978-01-01

    Arthropathy was evaluated in six patients with severe hemophilia (factor VIII<1%) using the technique of blood pool scanning. Employing an in vivo method for erythrocyte labelling with technetium-99m, a dynamic perfusion sequence was obtained using a scintillation camera over the joint(s) to be examined. Subsequently, equilibrium blood pool images of the joints were obtained to determine regional blood volume. In young patients with repeated episodes of acute hemarthrosis, increased vascularity and increased blood pool in the affected joints were demonstrated. In older patients with fixed, contracted joints and degenerative arthropathy, vascularity and regional blood volume were not abnormal. Blood pool scanning is a safe, non-invasive technique that augments the clinical and radiographic examination of the joints. The method is helpful in distinguishing acute joint bleeding from chronic synovitis and arthritis, and may prove useful in selecting patients for synovectomy. (author)

  6. Analysis of 81Kr in groundwater using laser resonance ionization spectroscopy

    International Nuclear Information System (INIS)

    Kramer, S.D.; Hurst, G.S.; Chen, C.H.

    1985-10-01

    A new analytical technique based on resonant ionization of krypton with a vacuum ultraviolet (VUV) laser source was used to determine low-level 81 Kr concentrations in groundwater. The long half-life (210,000 years) and low concentration (1.3 x 10 3 81 Kr atoms per liter of modern water at 10 0 C) make the detection of 81 Kr by radioactive counting techniques extremely difficult. In this method, krypton gas was removed from water taken from an underground Swiss aquifer using standard cryogenic and chromatographic techniques. Stable krypton isotopes were then reduced by a factor of 10 7 by a two-stage isotopic enrichment cycle using a commercially available mass spectrometer. The enriched gas containing about 10 8 stable krypton atoms and about 10 3 atoms of 81 Kr was implanted into a silicon disc. This disc was then placed in the high vacuum final counting chamber and the krypton was released by laser annealing. This chamber contained a quadrupole mass spectrometer which used a pulsed VUV laser source as the ionizer. The measured signal indicated that the sample contained 1200 (+-300) atoms of 81 Kr

  7. Clinical assessment of a commercial delivery system for aerosol ventilation scanning by comparison with Krypton-81m

    International Nuclear Information System (INIS)

    Wollmer, P.; Eriksson, L.; Andersson, A.

    1985-01-01

    A commercial aerosol delivery system for ventilation scanning was evaluated in 23 patients with lung disease involving regional disturbances of ventilation. Ventilation scans obtained after inhalation of an aerosol labeled with In-113m were compared with Kr-81m ventilation scans. An indirect comparison was also made with a settling bag technique. There was close agreement between the aerosol and the Kr-81m ventilation scans in all of the patients. The aerosol outlined the ventilated parts of the lung adequately, and central deposition of particles was minimal. The penetration of the aerosol into the lung was higher with the delivery system that with a settling bag system. The aerosol delivery system appears suitable for clinical pulmonary ventilation scintigraphy

  8. Significance of single ventilation/perfusion mismatches in krypton-81m/technetium-99m lung scintigraphy

    International Nuclear Information System (INIS)

    Rosen, J.M.; Palestro, C.J.; Markowitz, D.; Alderson, P.O.

    1986-01-01

    The significance of a single area of ventilation/perfusion (V/P) mismatch in lung scans performed on patients suspected of pulmonary embolism (PE) was evaluated. Ten of 20 patients with this scan finding were found to have PE. An intermediate probability of PE was found with segmental (71%) or subsegmental (45%) single V/P mismatches. Seven of 16 patients with a single V/P mismatch and without a matching radiographic opacity had PE. Three of the four patients who had a V/P mismatch and a matching radiographic opacity were found to have PE. Multiview ventilation imaging with 81mKr was found to have advantages for the evaluation of single V/P mismatches. Based on the data available at this time, a single V/P mismatch suggests an intermediate probability of PE

  9. 99mTc-MDP combined blood pool and bone phase radionuclide imaging in papain-injected carpal joints

    International Nuclear Information System (INIS)

    Metcalf, M.R.; Twardock, A.R.; Sanecki, R.K.

    1985-01-01

    Scintigraphic changes, i.e., increased activity, were induced by 1% papain, dissolved in phosphate-buffered physiologic saline (pH 7.4), injected into one antebrachiocarpal joint in each of eight dogs. Scintigraphic evaluation was by the use of combined blood pool and bone phase scintigraphy of affected and normal carpi over a 28-day period. The qualitative and quantitative scintigraphic appearance in injected carpal joints were very similar in both blood pool and bone phases. The clinical use of combined blood pool and bone phase scintigraphy to diagnose early inflammatory joint changes appears limited

  10. Automated determination of the right ventricular ejection fraction by digital processing of sup(81m)Kr scintigrams

    International Nuclear Information System (INIS)

    Elfner, R.; Vaknine, R.; Knapp, W.H.; Tillmanns, H.; Lorenz, W.J.

    1986-01-01

    A method is presented for the automated determination of the right ventricular ejection fraction (RVEF) by digital image processing of scintigrams obtained by intravenous infusion of Krypton 81m (sup(81m)Kr) dissolved in a glucose solution. End-diastolic and end-systolic sum pictures were computed by the addition of approximately 30-40 frames selected from the time-activity curve of a preliminary, manually drawn, right ventricular region of interest. After processing these two images with an adaptive Wiener filter, the right ventricular contour was determined by a recently developed algorithm using morphological and functional criteria. The RVEF was calculated for a series of 51 patients from the counts in the detected right ventricular regions in the end-diastolic and end-systolic sum images. In 16 patients without evidence of cardiopulmonary disease, the mean RVEF was 50+-6.1%. RVEF was significantly reduced in 18 patients with obstructive pulmonary disease (42+-6.5%) and in 17 patients with congestive cardiomyopathy (36+-7.1%). The correlation coefficient between two determinations of the RVEF was r=0.94. Through digital image processing, the determination of the RVEF by radioventriculography with sup(81m)Kr showed high reliability and reproducibility. (orig.)

  11. Design documentation: Krypton encapsulation preconceptual design

    International Nuclear Information System (INIS)

    Knecht, D.A.

    1994-10-01

    US EPA regulations limit the release of Krypton-85 to the environment from commercial facilities after January 1, 1983. In order to comply with these regulations, Krypton-85, which would be released during reprocessing of commercial nuclear fuel, must be collected and stored. Technology currently exists for separation of krypton from other inert gases, and for its storage as a compressed gas in steel cylinders. The requirements, which would be imposed for 100-year storage of Krypton-85, have led to development of processes for encapsulation of krypton within a stable solid matrix. The objective of this effort was to provide preconceptual engineering designs, technical evaluations, and life cycle costing data for comparison of two alternate candidate processes for encapsulation of Krypton-85. This report has been prepared by The Ralph M. Parsons Company for the US Department of Energy

  12. Design documentation: Krypton encapsulation preconceptual design

    Energy Technology Data Exchange (ETDEWEB)

    Knecht, D.A. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1994-10-01

    US EPA regulations limit the release of Krypton-85 to the environment from commercial facilities after January 1, 1983. In order to comply with these regulations, Krypton-85, which would be released during reprocessing of commercial nuclear fuel, must be collected and stored. Technology currently exists for separation of krypton from other inert gases, and for its storage as a compressed gas in steel cylinders. The requirements, which would be imposed for 100-year storage of Krypton-85, have led to development of processes for encapsulation of krypton within a stable solid matrix. The objective of this effort was to provide preconceptual engineering designs, technical evaluations, and life cycle costing data for comparison of two alternate candidate processes for encapsulation of Krypton-85. This report has been prepared by The Ralph M. Parsons Company for the US Department of Energy.

  13. Pulmonary function and /sup 81m/Kr scans in obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, E [Veterans Administration Hospital, Hines, IL; Mayron, L W; Gergans, G A; Shponka, S; Barnes, W E; Friedman, A M; Gindler, J E; Fishman, H; Sharp, J T

    1981-01-01

    Pulmonary ventilation in 13 normal subjects and in 18 patients with known chronic obstructive pulmonary disease (COPD) has been characterized with two modalities. Comparison consisted of correlating standard pulmonary function tests (PFT) and scintigraphic images of the lungs under steady state conditions during tidal respiration of krypton-81m. The lung scintigram was evaluated by inspection and a computer generated histogram in which the ratio of low level and high level ventilation of the lung was determined. Pulmonary function tests were the basis for verifying normality in 13 subjects. Scintigraphic imaging and histogram analysis in 18 patients with COPD produced two false negative results by each method. The combined scintigraphic histogram results correctly defined 13 of 13 normal subjects. The two scintigraphic methods differentiated normal subjects from patients with known COPD with a high level of comparability to PFT.

  14. Krypton purification (1961); Purification du krypton (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Larher, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Institut Fourier, 38 - Grenoble (France)

    1961-07-01

    The amount of xenon in otherwise very pure krypton can be reduced from 1.5 to 0.0025 per cent approximately by passage through an activated carbon column at dry-ice temperature. The circulation of the krypton is effected by condensing at -196 deg. C and then evaporating. (author) [French] Le taux de xenon dans du krypton par ailleurs tres pur est ramene de 1,5 pour cent a 0,0025 pour cent environ au cours d'un passage a travers une colonne de charbon actif a la temperature de la carboglace. La circulation du krypton se fait par condensation a -196 deg. C, puis evaporation. (auteur)

  15. Krypton-enhanced ventilation CT with dual energy technique: experimental study for optimal krypton concentration.

    Science.gov (United States)

    Chung, Yong Eun; Hong, Sae Rom; Lee, Mi-Jung; Lee, Myungsu; Lee, Hye-Jeong

    2014-11-01

    To assess the feasibility of krypton-enhanced ventilation CT using dual energy (DE) technique for various krypton concentrations and to determine the appropriate krypton concentration for DE ventilation CT through an animal study. Baseline DECT was first performed on seven New Zealand white rabbits. The animals were then ventilated using 20%, 30%, 40%, 50%, 60%, to 70% krypton concentration, and DECT was performed for each concentration. Krypton extraction was performed through a workstation, and results were displayed on a color map. Overlay Hounsfield unit (HU) values were obtained by two observers in consensus readings. A linear mixed model was used to correlate overlay HU values and krypton concentrations. Visual assessments of the homogeneity of krypton maps were also performed. Mean overlay HU values according to krypton concentration were as follows; 20% krypton, 1.68 ± 5.15; 30% krypton, 3.73 ± 5.93; 40% krypton, 6.92 ± 5.51; 50% krypton, 10.88 ± 5.17; 60% krypton, 14.54 ± 4.23; and 70% krypton, 18.79 ± 3.63. We observed a significant correlation between overlay HU values on krypton maps and krypton concentrations (P krypton color maps, all observers determined universal enhancement on the 70% krypton map for all animals. It is feasible to evaluate lung ventilation function using DECT with a krypton concentration of at least 70%.

  16. Study on 99Tcm-DTPA-HSA as a new blood pool scanning agent

    International Nuclear Information System (INIS)

    Liu Yunzhong; Zhang Zheng; Wu Qingwen

    1994-01-01

    The biological behavior of 99 Tc m -DTPA-HSA, 99 Tc m -RBC(in vivo) and 99 Tc m -HSA are studied in rabbits. Excellent cardiac blood-pool images are obtained by 99 Tc m -DTPT-HSA and 99 Tc m -RBC. Biodistribution studies show that 99 Tc m -DTPA-HSA has less accumulation than 99 Tc m -RBC in lungs and liver. They have similar count ratio of the cardiac blood pool to whole body. Ratio of heart/liver is 0.85 for 99 Tc m -DTPA-HSA, 0.95 for 99 Tc m -RBC and 0.62 for 99 Tc m -HSA. 99 Tc m -DTPA-HSA is a promising agent. It is readily performed only by single in vivo injection

  17. Clinical usefullness of ECG-triggered single photon emission comuter tomography of blood-pool

    International Nuclear Information System (INIS)

    Eilles, Chr.; Boerner, W.; Strauss, P.; Gerhards, W.; Reiners, Ch.

    1982-01-01

    ECT allows direct measurement of the volume of an organ and imaging without disturbing background-superposition. This makes ECT to an useful instrument for ECG-gated blood-pool imaging. Acquisition is made after the injection of 25 mCi Tc-99m HSA with a rotating Anger-Camera-System. ECG-gated imaging is done for each projection; herewith 50-70 cycles per projection are added according to the phase of the heart-cycle. Transversal-Sections of the heart are reconstructed with filtered-back-projection. For each slice a representative cycle, consisting of 10-16 frames, is computed. As shown by our group before a good quality of the reconstructed images can be obtained. Comparison is made with the results of the ECG-gated blood-pool-ECT, the results of the conventional blood-pool-studies and with the results of Laevo-Cardiography. (Author)

  18. Nuclear reactions and application to production rates of krypton in extraterrestrial materials

    International Nuclear Information System (INIS)

    Lavielle, B.

    1982-01-01

    Noble gases have been largely outgassed from most solar system materials through several heating processes. Consequently, their cosmogenic component, produced by cosmic-ray-induced nuclear reactions near the surface of atmosphere-free planetary objects, is detectable in meteorites and lunar samples. This work deals with the production of cosmogenic Krypton in the four main targets Zr, Y, Sr and Rb. Excitation functions of Krypton isotopes with A = 78, 80, 81, 82, 83, 84, 85 and 86 were mass-spectrometrically measured in Y and Zr targets bombarded with 0.059, 0.075, 0.168, 0.200, 1.0, 2.5 and 24 GeV protons. Also the Krypton relative cross sections were measured in Sr at 0.168 GeV. The results, combined with a general survey of nuclear reactions in Ga to Nb targets, permitted the development of new systematics in order to estimate unknown cross-sections in Rb and Sr. Measured and estimated excitation functions allowed to calculate the concentrations and isotopic ratios of cosmogenic Krypton in same well-documented lunar samples. Compared to observed values in 9 rocks, 83 Kr is predicted with a precision better than 33% and the production ratios sup(i)Kr/ 83 Kr are predicted to better than 25%. Also it is concluded that the cosmogenic ratios 86 Kr/ 83 Kr and 81 Kr/ 83 Kr are dependent on the main target elements concentrations [fr

  19. Survey of analytical methods for environmental monitoring of krypton-85

    International Nuclear Information System (INIS)

    Jaquish, R.E.; Moghissi, A.A.

    1973-01-01

    Numerous methods have been developed for measuring krypton-85 in air as krypton ultimately accumulates in air once it is released into the environment. However, krypton-85 can be present in other media such as natural gas from wells stimulated with nuclear devices or in water when krypton-85 is used for aeration studies. Methods for the measurement of ambient levels of krypton-85 require a concentration of krypton from a large air sample of one m 3 or more. If elevated levels are to be measured, carrier krypton may be used provided the contamination of atmospheric krypton with krypton-85 does not interfere with the measurement. In certain cases, such as in the vicinity of nuclear fuel processing plants, direct measurement techniques may be used. A variety of techniques are employed for krypton-85 counting. At low levels, internal gas counting or organic scintillation is used to measure the beta emission of this radionuclide. At higher levels the gamma emission of krypton-85 may be measured using scintillation or solid state gamma spectroscopic methods. Techniques for collection of the sample, concentration of krypton, and radioactivity measurement of krypton-85 are discussed and various processes are critically evaluated and compared

  20. Ionization relaxation in shock-heated krypton-argon mixtures

    International Nuclear Information System (INIS)

    Ezumi, Hiromichi; Kawamura, Masahiko; Yokota, Toshiaki.

    1977-01-01

    The ionization relaxation processes behind shock waves in pure krypton and krypton-argon mixtures have been investigated using a Mach-Zehnder interferometer technique. The incident shock velocity was fixed in the neighborhood of Us=2800 m/sec, and the initial pressure was fixed at 0.95 Torr. The experimental results were compared with theoretical values based on the two-step collisional ionization model taking into account of the wall boundary-layer effect. The slope constants of excitation cross section against relative kinetic energy between krypton atom-atom collisions, krypton atom-electron collisions, and krypton-argon atom-atom collisions were determined to be 4.2 x 10 -19 cm 2 /eV, 1.2 x 10 -17 cm 2 /eV, and 4.2 x 10 -19 cm 2 /eV, respectively. (auth.)

  1. A Giant Hepatic Hemangioma Complicated by Kasabach-Merritt Syndrome: Findings of Tc-99m RBC Scintigraphy and SPECT Including a Total Body Blood Pool Imaging Study

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Lim, Seok Tae; Kim, Dong Wook; Yim, Chang Yeol [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-02-15

    Kasabach-Merritt syndrome (KMS) consists of thrombocytopenia, microangiopathic hemolytic anemia, and localized consumption coagulopathy that develops within vascular hemangioma. This syndrome may also be associated with occult hemangiomas located at various sites. Tc-99m RBC scintigraphy and SPECT have proven to be reliable for confirming or excluding hemangioma. Total body blood pool imaging study during the scintigraphy also provides a means of screening for occult lesions. The authors report the case of a 29-year-old man who presented with a giant hepatic hemangioma complicated by KMS, and underwent Tc-99m RBC scintigraphy and SPECT including a total body blood pool imaging study.

  2. Pulmonary capillary wedge pressure, as inferred from lung areas in gated blood-pool scintigrams: concise communication

    International Nuclear Information System (INIS)

    Urbina, A.; Okada, R.D.; Palacios, I.; Osbakken, M.; Strauss, H.W.

    1981-01-01

    To determine whether the apex-to-base distribution of pulmonary blood volume, as obtained from gated cardiac blood-pool scans, could be used as a noninvasive method to estimate mean pulmonary capillary wedge pressure (PCWP), gated blood-pool scans were analyzed in 77 patients who also had PCWP measurements at cardiac catheterization. Ten of these patients had gated cardiac blood-pool scans and PCWP measurements both at rest and during exercise. The apex-to-base distribution of pulmonary blood volume was determined from the end-systolic frame of the left anterior oblique view by placing equal-sized regions of interest over the apex and base of the right lung. The ratio of apex counts over base counts (A/B ratio) was considered abnormal if greater than unity. The mean A/B ratio was 1.15 +/- 0.27 (1 s.d.) for the 32 studies associated with an abnormal mean PCWP (greater than 12 mm Hg). The mean A/B ratio was 0.85 +/- 0.23 for the 55 studies associated with a normal mean PCWP (p less than 0.01 comparing normal group with abnormal). The sensitivity of the A/B ratio for a mean PCWP greater than 12 mm Hg was 81%R (26/32). The specificity of the A/B ratio for a mean PCWP greater than or equal to 12 mm Hg was 89% (49/55). Thus, noninvasive determination of the pulmonary apex-to-base ratio from gated cardiac blood-pool scans appears to differentiate subjects with normal and abnormal mean pulmonary capillary wedge pressures

  3. Phase analysis in gated blood pool tomography

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro

    1984-01-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome. (author)

  4. Cardiac blood pool emission tomography

    International Nuclear Information System (INIS)

    Itti, R.; Philippe, L.; Lorgeron, J.M.; Charbonnier, B.; Raynaud, P.; Brochier, M.

    1983-01-01

    After blood pool labeling using technetium-99m, a series of cardiac pictures is acquired during the rotation of a gamma-camera about the patient. Computer processing leads to reconstruction of various tomographic slices from the original planar projection. Electrocardiographic gating selects the different phases of the cardiac cycle. Individual slices through the left ventricular region are added in order to provide ''thick'' slices on which global and regional parameters of the left ventricular function can be determined. Due to the proportionality existing between count rates and labeled blood volumes, any geometrical model can be avoided. The delineation of regions of interest for count integration is made easier due to the absence of superimposition of structures; no correction for background is necessary. Tomography thus appears to be more consistent and more accurate than the classical methods using planar projections. In addition, right ventricular morphological and kinetic studies can be performed in the same conditions as for the left ventricle [fr

  5. Measurement of krypton-85 in the atmosphere with a portable apparatus

    International Nuclear Information System (INIS)

    Okai, T.

    1984-01-01

    A portable apparatus was developed for the rapid collection, separation and counting of krypton-85 in environmental air samples. The apparatus consists of a molecular sieve trap for the elimination of H 2 O and CO 2 , a charcoal trap for the collection of krypton, a chromatographic column for the isolation of krypton in the air sample and a vial for the disolution of krypton in the scintillation solution. With this apparatus, krypton can be collected from half a cubic meter of air with 94% recovery in about 3 hrs. The measurements of krypton-85 were done several time in Fukuoka area from Jan. 30 to Dec. 9, 1981. The krypton-85 concentration was found to be approximately 21 pCi/m 3 air. The results were compared with those obtained by foreign investigators. (author)

  6. Krypton Ion Thruster Performance

    Science.gov (United States)

    Patterson, Michael J.; Williams, George J.

    1992-01-01

    Preliminary data were obtained from a 30 cm ion thruster operating on krypton propellant over the input power range of 0.4 to 5.5 kW. The data presented are compared and contrasted to the data obtained with xenon propellant over the same input power envelope. Typical krypton thruster efficiency was 70 percent at a specific impulse of approximately 5000 s, with a maximum demonstrated thrust to power ratio of approximately 42 mN/kW at 2090 s specific impulse and 1580 watts input power. Critical thruster performance and component lifetime issues were evaluated. Order of magnitude power throttling was demonstrated using a simplified power-throttling strategy.

  7. Technical feasibility of krypton-85 storage in sodalite

    International Nuclear Information System (INIS)

    Benedict, R.W.; Christensen, A.B.; Del Debbio, J.A.; Keller, J.H.; Knecht, D.A.

    1979-01-01

    Based on these experimental results, the process that is technically feasible for a reference 2000 metric ton of heavy metal (MTHM) per year reprocessing plant producing approx. 17 MCi or approx. 190 m 3 at STP would encapsulate krypton at approx. 20 cm 3 /g from krypton at temperatures greater than 575 0 C and pressures greater than 1600 atm with one batch a day in a 58-L high pressure vessel. Based on preliminary measurements at 500 0 C, the same process also would be feasible for a 70% krypton and 30% xenon mixture. 7 figures

  8. Magnetic resonance angiography with blood-pool contrast agents: future applications

    International Nuclear Information System (INIS)

    Fink, C.; Goyen, M.; Lotz, J.

    2007-01-01

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  9. Magnetic resonance angiography with blood-pool contrast agents: future applications

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Univ. Hospitals, Grosshadern, Munich (Germany); Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Lotz, J. [Hannover Medical School, Hannover (Germany)

    2007-03-15

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  10. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  11. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V.

    1989-01-01

    Blood-pool subtraction has been proposed to enhance 111 In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging

  12. Radioactive krypton gas separation

    International Nuclear Information System (INIS)

    Martin, J.R.

    1976-01-01

    Radioactive krypton is separated from a gas mixture comprising nitrogen and traces of carbon dioxide and radioactive krypton by selective adsorption and then cryogenic distillation of the prepurified gas against nitrogen liquid to produce krypton bottoms concentrate liquid, using the nitrogen gas from the distillation for two step purging of the adsorbent. 16 Claims, 8 Drawing Figures

  13. Changes in distribution of hepatic blood flow induced by intra-arterial infusion of angiotensin II in human hepatic cancer

    International Nuclear Information System (INIS)

    Sasaki, Y.; Imaoka, S.; Hasegawa, Y.

    1985-01-01

    Changes in the distribution of the hepatic blood flow induced by intra-arterial infusion of angiotensin II (AT-II) were studied in human hepatic cancers using extremely short-lived radioisotope (RI) (krypton 81 m [/sup 81m/Kr]; half-life, 13 seconds). After the start of continuous infusion of AT-II, the radioactivity of the tumor showed about a two-fold increase, whereas that of the nontumor region decreased to about one half as much as the level before the infusion. Consequently, the mean ratio of the arterial blood flow in the tumor region to that in the nontumor region (T/N ratio) increased to 3.30 (P less than 0.001). The T/N ratio showed a peak before the peripheral blood pressure reached the maximum, and thereafter tended to decrease. Intra-arterial infusion of AT-II raised the T/N ratio more obviously than did intravenous infusion of the drug, with less rise in the peripheral blood pressure. It is believed that intra-arterial infusion chemotherapy with local use of AT-II enables better accessibility of chemotherapeutic drugs to tumors

  14. Gene expression changes in blood RNA after swimming in a chlorinated pool.

    Science.gov (United States)

    Salas, Lucas A; Font-Ribera, Laia; Bustamante, Mariona; Sumoy, Lauro; Grimalt, Joan O; Bonnin, Sarah; Aguilar, Maria; Mattlin, Heidi; Hummel, Manuela; Ferrer, Anna; Kogevinas, Manolis; Villanueva, Cristina M

    2017-08-01

    Exposure to disinfection by-products (DBP) such as trihalomethanes (THM) in swimming pools has been linked to adverse health effects in humans, but their biological mechanisms are unclear. We evaluated short-term changes in blood gene expression of adult recreational swimmers after swimming in a chlorinated pool. Volunteers swam 40min in an indoor chlorinated pool. Blood samples were drawn and four THM (chloroform, bromodichloromethane, dibromochloromethane and bromoform) were measured in exhaled breath before and after swimming. Intensity of physical activity was measured as metabolic equivalents (METs). Gene expression in whole blood mRNA was evaluated using IlluminaHumanHT-12v3 Expression-BeadChip. Linear mixed models were used to evaluate the relationship between gene expression changes and THM exposure. Thirty-seven before-after pairs were analyzed. The median increase from baseline to after swimming were: 0.7 to 2.3 for MET, and 1.4 to 7.1μg/m 3 for exhaled total THM (sum of the four THM). Exhaled THM increased on average 0.94μg/m 3 per 1 MET. While 1643 probes were differentially expressed post-exposure. Of them, 189 were also associated with exhaled levels of individual/total THM or MET after False Discovery Rate. The observed associations with the exhaled THM were low to moderate (Log-fold change range: -0.17 to 0.15). In conclusion, we identified short-term gene expression changes associated with swimming in a pool that were minor in magnitude and their biological meaning was unspecific. The high collinearity between exhaled THM levels and intensity of physical activity precluded mutually adjusted models with both covariates. These exploratory results should be validated in future studies. Copyright © 2017. Published by Elsevier B.V.

  15. High resolution krypton M/sub 4,5/ x-ray emission spectra

    International Nuclear Information System (INIS)

    Perera, R.C.C.; Hettrick, M.C.; Lindle, D.W.

    1987-10-01

    High resolution M/sub 4,5/ (3d → 4p) x-ray emission spectra from a krypton plasma were measured using a recently developed grazing-incidence reflection-grating monochromator/spectrometer with very high flux rates at extreme ultraviolet and soft x-ray wave lengths. The nominal resolving power of the instrument, E/ΔE, is about 300 in this energy range (∼80 eV). Three dipole-allowed 3d → 4p emission lines were observed at 80.98 eV, 80.35 eV and 79.73 eV. A broad peak at about 82.3 eV is tentatively assigned to transitions resulting from Kr 2+ , and effects of excitation energy on M/sub 4,5/ x-ray emission were observed. 9 refs., 3 figs., 1 tab

  16. Carbon dioxide-krypton separation and radon removal from nuclear-fuel-reprocessing off-gas streams

    International Nuclear Information System (INIS)

    Hirsch, P.M.; Higuchi, K.Y.; Abraham, L.

    1982-07-01

    General Atomic Company (GA) is conducting pilot-plant-scale tests that simulate the treatment of radioactive and other noxious volatile and gaseous constituents of off-gas streams from nuclear reprocessing plants. This paper reports the results of engineering-scale tests performed on the CO 2 /krypton separation and radon holdup/decay subsystems of the GA integrated off-gas treatment system. Separation of CO 2 from krypton-containing gas streams is necessary to facilitate subsequent waste processing and krypton storage. Molecular sieve 5A achieved this separation in dissolver off-gas streams containing relatively low krypton and CO 2 concentrations and in krypton-rich product streams from processes such as the krypton absorption in liquid carbon dioxide (KALC) process. The CO 2 /krypton separation unit is a 30.5-cm-diameter x 1.8-m-long column containing molecular sieve 5A. The loading capacity for CO 2 was determined for gas mixtures containing 250 ppM to 2.2% CO 2 and 170 to 750 ppM krypton in either N 2 or air. Gas streams rich in CO 2 were diluted with N 2 to reduce the temperature rise from the heat of adsorption, which would otherwise affect loading capacity. The effluent CO 2 concentration prior to breakthrough was less than 10 ppM, and the adsorption capacity for krypton was negligible. Krypton was monitored on-line with a time-of-flight mass spectrometer and its concentration determined quantitatively by a method of continuous analysis, i.e., selected-ion monitoring. Radon-220 was treated by holdup and decay on a column of synthetic H-mordenite. The Rn-220 concentration was monitored on-line with flow-through diffused-junction alpha detectors. Single-channel analyzers were utilized to isolate the 6.287-MeV alpha energy band characteristic of Rn-220 decay from energy bands due to daughter products

  17. Radioactive 85Kr in krypton enriched with a light isotope

    International Nuclear Information System (INIS)

    Kuz'minov, V.V.; Novikov, V.M.; Pomanskii, A.A.; Pritychenko, B.V.; Vieiar, J.; Garcia, E.; Morales, A.; Morales, J.; Nunes-Lagos, R.; Piumendon, J.

    1993-01-01

    Radioactive krypton 85, a product of nuclear power generation, is known to be accumulating in the atmosphere continuously. Its volumetric activity in natural krypton is 700-800 Bq/liter. This can cause difficulties, e.g., in the fabrication of nuclear radiation detector for high-mass krypton. Krypton with a reduced 85 Kr content can be obtained by isotope separation. As part of an experiment to look for two-positron decay and conversion of an atomic electron to a positron in 78 Kr, Saenz measured the 85 Kr content in 78 Kr-enriched krypton. A mixture of two 85 Kr samples was used as the working substance of a cylindrical ionization chamber. The useful volume (1.33 liter) of the chamber contained 35.3 liters of gas at ∼2.5 kPa. The energy resolution of the detector at an energy of 0.511 MeV was 3.8%. The measurements were made in a passive lead shield 20 cm thick in an underground laboratory at a depth of 675 m water equivalent. Results are presented for counting rates in low-energy regions, contribution of krypton-85 to background, and the volumetric activity of krypton-85

  18. Slower lower limb blood pooling in young women with orthostatic intolerance.

    Science.gov (United States)

    Lindenberger, Marcus; Länne, Toste

    2015-01-01

    What is the central question of this study? Orthostatic stress is mostly caused by venous blood pooling in the lower limbs. Venous distension elicits sympathetic responses, and increased distension speed enhances the cardiovascular response. We examine whether lower limb blood pooling rate during lower body negative pressure is linked to orthostatic intolerance. What is the main finding and its importance? A similar amount of blood was pooled in the lower limb, but at a slower rate in women who developed signs of orthostatic intolerance. The difference in blood pooling rate increased with orthostatic stress and was most prominent at a presyncope-inducing level of lower body negative pressure. The findings have implications for the pathophysiology as well as treatment of orthostatic intolerance. Vasovagal syncope is common in young women, but its aetiology remains elusive. Orthostatic stress-induced lower limb blood pooling is linked with central hypovolaemia and baroreceptor unloading. Venous distension in the arm elicits a sympathetic response, which is enhanced with more rapid distension. Our aim was to study both the amount and the speed of lower limb pooling during orthostatic stress and its effects on compensatory mechanisms to maintain cardiovascular homeostasis in women with orthostatic intolerance. Twenty-seven healthy women, aged 20-27 years, were subjected to a lower body negative pressure (LBNP) of 11-44 mmHg. Five women developed symptoms of vasovagal syncope (orthostatic intolerant) and were compared with the remaining women, who tolerated LBNP well (orthostatic tolerant). Lower limb blood pooling, blood flow and compensatory mobilization of venous capacitance blood were measured. Lower body negative pressure induced equal lower limb blood pooling in both groups, but at a slower rate in orthostatic intolerant women (e.g. time to 50% of total blood pooling, orthostatic intolerant 44 ± 7 s and orthostatic tolerant 26 ± 2 s; P intolerant women (P = 0

  19. Determination of right ventricular ejection fraction in children with cystic fibrosis, using krypton-81m

    International Nuclear Information System (INIS)

    Piepsz, A.; Ham, H.R.; Millet, E.; Dab, I.

    1984-01-01

    The diagnosis of cor pulmonale and incipient heart failure remains difficult to assess in cystic fibrosis (CF) on the basis of the clinical as well as the biological parameters. The measurement of the right ventricular ejection fraction has been facilitated these last years by the introduction of the radionuclide methods. Methodological difficulties are however encountered when Tc-99m RBC are used, and are mainly related to heart chambers superposition (equilibrium method) or the low count density (first pass method). Few papers have been published on RVEF in cystic fibrosis and the results are somewhat contradictory. The authors have recently introduced a new method for the determination of RVEF, using equilibrium study during continuous injection of Kr-81m in glucose solution. This method offers several advantages related to an increased accuracy and a favorable dosimetry. In 25 patients aged 2 to 23 years with CF, one or more RVEF studies were performed. The severity of the disease was evaluated on the basis of the clinical Schwachman score, the lung function tests, the ventilation scan and the pa02. RVEF tended to decrease with the progression of the lung disease, although, owing to the spread of the results, no RVEF could be predicted on the basis of the other parameters. The decrease of RVEF in patients with advanced lung disease was moderate and terminal lung disease was sometimes associated with normal right heart contractility

  20. Retention of krypton on polymethyl methacrylate

    International Nuclear Information System (INIS)

    Ciric, M.M.; Cvjeticanin, N.M.; Radak, B.B.

    1975-01-01

    Retention of krypton on polymethyl methacrylate was studied as a function of kryptonation pressure (P), temperature (T) and time (t). It was found that the dependence of the retained quantity on P, T, and t is in accordance with the diffusion theory. The optimum results (i.e., the maximum retained quantity and the best stability of the kryptonate) were obtained at elevated kryptonation temperatures (200 0 C). The diffusion coefficients of krypton in polymethyl methacrylate, determined from the dekryptonation process, vary from 1 x 10 -10 cm 2 /s to 0.2 x 10 -10 cm 2 /s for samples kryptonated at 20 0 C and 200 0 C respectively. The results have been discussed from the viewpoint of radiation and thermal stability of kryptonated polymethyl methacrylate. Inadequate radiation stability could be the main obstacle for practical purposes. (U.S.)

  1. Clinical blood pool MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Leiner, Tim [Maastrich University Medical Center (Netherlands). Dept. of Radiology; Goyen, Martin [University Medical Center Hamburg-Eppendorf (Germany); Rohrer, Mathias [Bayer Schering Pharma AG, Berlin (Germany). European Business Unit Diagnostic Imaging; Schoenberg, Stefan O. (eds.) [University Hospital Mannheim Medical Faculty Mannheim - Heidelberg Univ. (Germany). Dept. of Clinical Radiology and Nuclear Medicine

    2008-07-01

    Clinical Blood Pool MR Imaging - This excellent treatise on Vasovist {sup registered} created by a team of exceptional faculty who are pioneers in MR Angiography covers the basic techniques, safety, efficacy, image processing and pharmaco-economic details to successfully implement a new level of MRA image quality with this new contrast agent. Martin Prince, Cornell University, New York The editors and authors have made groundbreaking contributions towards establishing MR angiography in various investigative settings, rendering it more precise and applying it for diverse indications. The work presented here is founded upon the extensive experience of the editors, as well as the broad range of experience from other scientific working groups. Maximilian Reiser, Ludwig Maximilian University, Munich Vasovist {sup registered} (Gadofosveset), worldwide the first blood pool agent, has only recently become available for clinical use, but has already gained wide acceptance as a tool to improve magnetic resonance angiography. This book presents the first in-depth introduction to the basic physicochemical aspects of the agent, the application of Vasovist {sup registered} in clinical MRA, as well as potential clinical applications beyond MRA and patient management-related aspects. The first part of the book explains basic and technical properties of the agent and the differences of Vasovist {sup registered} compared to currently available extracellular agents. The second part contains detailed chapters on safety and efficacy. In the third part the focus is on MR angiographic applications, and in the fourth part of the book potential clinical fields beyond MRA are explored. All clinical chapters feature ready-to-use clinical protocols and a series of take home messages that concisely summarize the current role of blood pool imaging for each specific indication. (orig.)

  2. Kinetics of inhaled krypton in the blood of pregnant ewes and their fetuses

    International Nuclear Information System (INIS)

    Meznarich, H.K.; Sikov, M.R.; Ballou, J.E.

    1989-01-01

    There has been concern about exposure of pregnant women and their fetuses to radiokrypton (Kr-85) released to the general environment. This led to previous studies on the distribution and effects of inhaled Kr-85 in sheep and rats. The data on hematogenous concentrations obtained during and after continuous inhalation by pregnant ewes had neither been analyzed nor reported in detail, which led to the kinetic analyses reported in this communication. Indwelling catheters were placed in an artery and a vein of pregnant ewes, and into a fetal artery or vein at gestational ages between 93 and 123 days. Ewes were exposed for 1.5 to 2 hors via a face mask to an atmosphere of 50 nCi/ml (1850 Bq/ml) Kr-85 in air; mean respiration rates were about 20 breaths per min. Blood samples were collected from each catheter at intervals throughout the accumulation and steady-state periods, and during a 90-min period following discontinuation of exposure. Results from 7 ewes, in which complete sampling was obtained, showed that both maternal fetal blood concentrations of Kr rose rapidly and attained a steady state by approximately 1 hr after initiation of exposure. The steady state concentrations of Kr-85 were significantly higher in maternal venous blood than in maternal arterial or fetal blood. There were no significant concentration differences between fetal arterial and venous bloods. The rate of disappearance of Kr-85 (per min) from maternal and fetal blood after discontinuation of exposure, 0.17 ± 0.02 and 0.06 ± 0.01, respectively, were significantly different. Thus, krypton is freely accessible to the fetal blood and rapidly reaches and maintains an equilibrium state with maternal blood during continuous exposure, although it disappears from fetal blood less rapidly after cessation of exposure

  3. Krypton oxides under pressure

    OpenAIRE

    Zaleski-Ejgierd, Patryk; Łata, Paweł

    2015-01-01

    Under high pressure, krypton, one of the most inert elements is predicted to become sufficiently reactive to form a new class of krypton compounds; krypton oxides. Using modern ab-initio evolutionary algorithms in combination with Density Functional Theory, we predict the existence of several thermodynamically stable Kr/O species at elevated pressures. In particular, our calculations indicate that at approx. 300?GPa the monoxide, KrO, should form spontaneously and remain thermo- and dynamical...

  4. An evaluation of krypton propellant in Hall thrusters

    Science.gov (United States)

    Linnell, Jesse Allen

    Due to its high specific impulse and low price, krypton has long sparked interest as an alternate Hall thruster propellant. Unfortunately at the moment, krypton's relatively poor performance precludes it as a legitimate option. This thesis presents a detailed investigation into krypton operation in Hall thrusters. These findings suggest that the performance gap can be decreased to 4% and krypton can finally become a realistic propellant option. Although krypton has demonstrated superior specific impulse, the xenon-krypton absolute efficiency gap ranges between 2 and 15%. A phenomenological performance model indicates that the main contributors to the efficiency gap are propellant utilization and beam divergence. Propellant utilization and beam divergence have relative efficiency deficits of 5 and 8%, respectively. A detailed characterization of internal phenomena is conducted to better understand the xenon-krypton efficiency gap. Krypton's large beam divergence is found to be related to a defocusing equipotential structure and a weaker magnetic field topology. Ionization processes are shown to be linked to the Hall current, the magnetic mirror topology, and the perpendicular gradient of the magnetic field. Several thruster design and operational suggestions are made to optimize krypton efficiency. Krypton performance is optimized for discharge voltages above 500 V and flow rates corresponding to an a greater than 0.015 mg/(mm-s), where alpha is a function of flow rate and discharge channel dimensions (alpha = m˙alphab/Ach). Performance can be further improved by increasing channel length or decreasing channel width for a given flow rate. Also, several magnetic field design suggestions are made to enhance ionization and beam focusing. Several findings are presented that improve the understanding of general Hall thruster physics. Excellent agreement is shown between equipotential lines and magnetic field lines. The trim coil is shown to enhance beam focusing

  5. Dried blood spots of pooled samples for RHD gene screening in blood donors of mixed ancestry.

    Science.gov (United States)

    Silva-Malta, M C F; Araujo, N C Fidélis; Vieira, O V Neves; Schmidt, L Cayres; Gonçalves, P de Cassia; Martins, M Lobato

    2015-10-01

    In this study, we present a strategy for RHD gene screening based on real-time polymerase chain reaction (PCR) using dried blood spots of pooled samples. Molecular analysis of blood donors may be used to detect RHD variants among the presumed D-negative individuals. RHD genotyping using pooled samples is a strategy to test a large number of samples at a more reasonable cost. RHD gene detection based on real-time PCR using dried blood spots of pooled samples was standardised and used to evaluate 1550 Brazilian blood donors phenotyped as RhD-negative. Positive results were re-evaluated by retesting single samples using real-time PCR and conventional multiplex PCR to amplify five RHD-specific exons. PCR-sequence-specific primers was used to amplify RHDψ allele. We devised a strategy for RHD gene screening using dried blood spots of five pooled samples. Among 1550 serologically D-negative blood donors, 58 (3.74%) had the RHD gene. The non-functional RHDψ allele was detected in 47 samples (3.02%). The present method is a promising strategy to detect the RHD gene among presumed RhD-negative blood donors, particularly for populations with African ancestry. © 2015 British Blood Transfusion Society.

  6. Immobilization of krypton-85 in zeolite 5A and porous glass

    International Nuclear Information System (INIS)

    Christensen, A.B.; DelDebbio, J.A.; Knecht, D.A.; Tanner, J.E.; Cossel, S.C.

    1981-12-01

    This report demonstrates the technical and economic feasibility for immobilizing krypton-85 by high pressure/high temperature encapsulation in zeolite 5A or thirsty Vyco porous glass. Data are presented to show how process conditions affect the encapsulation and how to compact the zeolite beads with glass frit or other additives to form a fused mass with low dispersibility potential. Krypton specific loadings of 30 and 50 m 3 STP gas per m 3 solid are readily achieved at 100 MPa in porous glass at 900 0 C and zeolite 5A at 700 0 C. Krypton is encapsulated by a sintering process where the porous glass and zeolite 5A voids are sealed. With zeolite 5A, the initial water concentration has a catalytic effect on the sintering, resulting in a transition from crystalline zeolite 5A to an amorphous aluminosilicate. Krypton leakage experiments are used to predict leakage rates from glass or zeolite of less than 0.03% and 0.3% for 10-y storage at 300 and 400 0 C, respectively. Heating the loaded zeolite at 600 to 700 0 C for 4 h removes 0.1% of the total krypton which is loosely held and reduces the subsequent leakage rates at 300 to 400 0 C. Zeolite 5A is chosen as the preferred material to immobilize krypton-85. A preconceptual design and cost estimate is given for a facility to encapsulate 110% of the krypton production of a 2000 metric ton of heavy metal per year reprocessing plant, or 230 m 3 of gas containing 19 MCi of krypton-85. A hot isostatic press (HIP) with an isolated work zone of 8 or 16 L capacity is required to operate for 600 or 300 cycles per year, respectively. Existing HIP technology uses work zones from 1 to 3500 L capacity at similar production rates. A preliminary safety evaluation shows that an incredible worst case accident could be contained and the maximum off-site dose would be well below accident protective action guidance levels

  7. Krypton purification (1961)

    International Nuclear Information System (INIS)

    Larher, Y.

    1961-01-01

    The amount of xenon in otherwise very pure krypton can be reduced from 1.5 to 0.0025 per cent approximately by passage through an activated carbon column at dry-ice temperature. The circulation of the krypton is effected by condensing at -196 deg. C and then evaporating. (author) [fr

  8. Determination of the separation efficiencies of a single-stage cryogenic distillation setup to remove krypton out of xenon by using a (83m)Kr tracer method.

    Science.gov (United States)

    Rosendahl, S; Brown, E; Cristescu, I; Fieguth, A; Huhmann, C; Lebeda, O; Murra, M; Weinheimer, C

    2015-11-01

    The separation of krypton and xenon is of particular importance for the field of direct dark matter search with liquid xenon detectors. The intrinsic contamination of the xenon with radioactive (85)Kr makes a significant background for these kinds of low count-rate experiments and has to be removed beforehand. This can be achieved by cryogenic distillation, a technique widely used in industry, using the different vapor pressures of krypton and xenon. In this paper, we present an investigation on the separation performance of a single stage distillation system using a radioactive (83m)Kr-tracer method. The separation characteristics under different operation conditions are determined for very low concentrations of krypton in xenon at the level of (83m)Kr/Xe = 1.9 ⋅ 10(-15), demonstrating, that cryogenic distillation in this regime is working. The observed separation is in agreement with the expectation from the different volatilities of krypton and xenon. This cryogenic distillation station is the first step on the way to a multi-stage cryogenic distillation column for the next generation of direct dark matter experiment XENON1T.

  9. Evaluation of the vascular state of hepatic tumor with radioisotope angiography and blood pool scintigraphies (early and delayed)

    International Nuclear Information System (INIS)

    Aburano, Tamio; Tonami, Norihisa; Hisada, Kinichi

    1976-01-01

    Combined radioisotope examinations of hepatic tumors have been performed using α 1 -fetoprotein radioimmunoassay, radioisotope angiography of the liver, and some tumor positive imaging scintigraphies. However, with these methods, it is frequently impossible to differentiate metastatic cancers from benign focal lesions. Radioisotope angiography of the liver, and both early (5 min later)- and delayed (4 hours later) blood pool scintigraphies of the liver were done continuously after 10mCi of sup(99m)Tc-albumin intravenous injection, in cases of clearcut focal lesions on sup(99m)Tc-colloid liver scan. The relationships among these findings were examined. Four of seven cases with hepatoma and two of nine cases with metastatic cancer which had showed hypervascular findings on radioisotope angiogram showed clear blood pool activities in the area of focal defects on sup(99m)Tc-colloid scan although less than liver. On the other hand, none of hypovascular tumors on radioisotope angiogram showed blood pool activities. However, four hours later, in most malignant lesions, the lesion to liver activity ratio calculated from data processing system showed a much higher value than the ratio obtained 5 min later after injection, although two cases with benign focal lesions did not show such sequential change. The sequential evaluation of the vascular state of a hepatic tumor using radioisotope angiography and early-and delayed blood pool scintigraphies was supposed to be extremely useful for the elucidation of the nature of focal hepatic lesions on sup(99m)Tc-colloid scan, especially in differentiating hypovascular malignant- and benign lesions. (auth.)

  10. Solid sources of krypton-85

    International Nuclear Information System (INIS)

    Puig, J.R.; Sandier, J.

    1962-01-01

    Krypton-85, a β-emitter with a long half-life and low biological hazard, has considerable industrial potentialities. It is difficult, however, to manufacture sources since the element occurs in gaseous form and cannot be chemically fixed. The authors describe a method of krypton-fixation in a macromolecular matrix formed by mass polymerization of a liquid monomer containing krypton; they also give an account of the preparation of two types of source produced in this way-one enclosed in polystyrene, the other in polyvinyl acetate. Such sources lose krypton; the activity of the first decreases by 8 % daily, that of the second by 3 % daily. These apparent decays enable the diffusion coefficients of krypton in these polymers to be calculated. Diffusion appears to be prevented by the cross-linkages which exist in the polymers. (author) [fr

  11. Operation and technology development of the radioactive xenon and krypton detection equipment

    International Nuclear Information System (INIS)

    Lee, Wanno; Choi, Sangdo; Ji, Youngyong; Lim, Jong Myoung; Cho, Young Hyun; Kang, Han Beul; Lee, Hoon; Kang, Moon Ja; Choi, Kun Sik

    2013-03-01

    Operation and technology development of the radioactive xenon and krypton detection equipment - Advancement, independence of operation technology for BfS-IAR system(the simultaneous analysis of xenon and krypton) installed after North Korea nuclear tests in 2006 and establishment of background base-line for xenon and krypton radioactivity. - Enhanced detection and analysis capabilities for neighborhood nuclear activities through advanced research of noble gas detection technology. Results of the Project · The operation of xenon and krypton analysis system (BfS-IAR) · Operation of fixed adsorption system. · Operation of portable adsorption system · Exercise of emergency response and proficiency test with SAUNA. · Measurement of noble gas background at specific region in Korea. - Radioxenon levels at Dongdu Cheon is approximately 1.6 mBq/m 3 · Development of automation filling system for absorber cooling

  12. Separation, storage and disposal of krypton-85

    International Nuclear Information System (INIS)

    1980-01-01

    Technical means available for the retention of 85 Kr and its immobilization, storage and disposal are reviewed. Cryogenic processes for the separation of krypton and xenon from diluting gases are discussed in more detail. Besides the cryogenic processes, a liquid adsorption process for reprocessing off-gases and charcoal adsorption and membrane processes for reactor off-gases are also dealt with. The retained krypton can be stored in pressurized containers with air or water cooling. The containers can be kept in engineered storage facilities for an intermediate period or until the 85 Kr has decayed. Alternatively, the krypton may be encapsulated in a solid. The injection of gases containing krypton into suitable geologic strata may also be possible. Much of the equipment required for the separation and storage of krypton, well known from ordinary technology, often needs some adaptation. Further R and D work is, however, needed to solve some problems which are specific to highly concentrated fission krypton. The subject is reviewed under the following headings: methods available for the separation of krypton from off-gases; separation of krypton from reactor off-gas; separation of krypton from reprocessing off-gas; conditioning methods; engineering storage; transportation; disposal

  13. Immobilization of krypton-85 in zeolite 5A

    International Nuclear Information System (INIS)

    Christensen, A.B.; Del Debbio, J.A.; Knecht, D.A.; Tanner, J.E.; Cossel, S.C.

    1983-01-01

    This paper describes the technical feasibility and presents a summary of a preconceptual design and cost estimate for a process to immobilize krypton-85 by sintering in zeolite 5A at 700 0 C and 100 MPa for 2 to 4 h. Krypton loading of 30 to 60 m 3 at STP per m 3 solid can be achieved. The initial water concentration in zeolite 5A has a catalytic effect on the sintering rate and must be kept at about 1 wt% by heating prior to the encapsulation run. High initial water loadings and/or encapsulation times longer than 4 h must be avoided because the sintered zeolite 5A recrystallizes to an anorthite-type feldspar and releases the trapped krypton. Data are presented to show how the process conditions affect krypton encapsulation in zeolie 5A and how to assure the quality of the product. By adding a powdered glass frit to the commercial zeolite 5A 2 mm beads, a solid mass is formed during encapsulation, which can be further compacted using standard hot isotatic pressing techniques at 33 MPa and 600 0 C to form a fused glassy matrix enclosing the amorphous zeolite. A process for encapsulating the annual krypton-85 production at a commercial 2000 metric ton of heavy metal spent fuel reprocessing plant is developed. A hot isostatic press (HIP) with an isolated work zone of 8 or 16 L capacity is required to operate for 600 or 300 cycles per year, respectively. Existing HIP technology uses work zones from 1 to 3500 L capacity at similar production rates. A combined encapsulation/compaction cycle is proposed as an option to most effectively immobilize the krypton and the zeolite. A preconceptual design and cost estimate is given for a commercial-scale Kr encapsulation facility. The facility is designed to withstand a worst case rupture of the HIP. The maximum lease is estimated to result in an off-site dose well below accident protective action guidance levels

  14. Accurate virial coefficients of gaseous krypton from state-of-the-art ab initio potential and polarizability of the krypton dimer

    Science.gov (United States)

    Song, Bo; Waldrop, Jonathan M.; Wang, Xiaopo; Patkowski, Konrad

    2018-01-01

    We have developed a new krypton-krypton interaction-induced isotropic dipole polarizability curve based on high-level ab initio methods. The determination was carried out using the coupled-cluster singles and doubles plus perturbative triples method with very large basis sets up to augmented correlation-consistent sextuple zeta as well as the corrections for core-core and core-valence correlation and relativistic effects. The analytical function of polarizability and our recently constructed reference interatomic potential [J. M. Waldrop et al., J. Chem. Phys. 142, 204307 (2015)] were used to predict the thermophysical and electromagnetic properties of krypton gas. The second pressure, acoustic, and dielectric virial coefficients were computed for the temperature range of 116 K-5000 K using classical statistical mechanics supplemented with high-order quantum corrections. The virial coefficients calculated were compared with the generally less precise available experimental data as well as with values computed from other potentials in the literature {in particular, the recent highly accurate potential of Jäger et al. [J. Chem. Phys. 144, 114304 (2016)]}. The detailed examination in this work suggests that the present theoretical prediction can be applied as reference values in disciplines involving thermophysical and electromagnetic properties of krypton gas.

  15. Krypton oxides under pressure.

    Science.gov (United States)

    Zaleski-Ejgierd, Patryk; Lata, Pawel M

    2016-02-02

    Under high pressure, krypton, one of the most inert elements is predicted to become sufficiently reactive to form a new class of krypton compounds; krypton oxides. Using modern ab-initio evolutionary algorithms in combination with Density Functional Theory, we predict the existence of several thermodynamically stable Kr/O species at elevated pressures. In particular, our calculations indicate that at approx. 300 GPa the monoxide, KrO, should form spontaneously and remain thermo- and dynamically stable with respect to constituent elements and higher oxides. The monoxide is predicted to form non-molecular crystals with short Kr-O contacts, typical for genuine chemical bonds.

  16. Long-term storage of recovered krypton

    International Nuclear Information System (INIS)

    Horii, Yuji; Yamamoto, Yoshimasa

    1983-01-01

    Various storage methods for krypton-85 recovered from a nuclear fuel reprocessing plant are under development in many countries. These methods include:(1) direct storage in pressurized cylinders, (2) storage of krypton adsorbed on charcoal or zeolite in pressurized cylinders and (3) immobilization (encapsulation) in zeolite. A krypton storage facility using pressurized cylinders has been constructed in the krypton recovery pilot plant in Tokaimura and other methods are now under development. These three methods are evaluated and the features of the constructed facility are also reported. (author)

  17. Photon W value for krypton in the M-shell transition region.

    Science.gov (United States)

    Saito, N; Suzuki, I H

    2001-09-01

    Absolute W values for krypton have been measured for incident X rays with energies in the range of 85 to 1000 eV, using monochromatic synchrotron radiation and a multiple-electrode ion chamber technique that yields the absolute intensity of the X-ray beam and the photoabsorption cross section. To improve the purity of the incident X rays, the electron storage ring was operated at an energy lower than the normal mode, and thin filters were used. The W values are derived from the measured photon intensity and photoabsorption cross section, using the mean charges of the residual ions obtained in previous work. A considerable oscillation of the W values with the photon energy was found in the region near the krypton 3d electron ionization edge. The results are discussed and compared with data in the literature for low-energy electrons and with the calculations from a model that includes multiple photoionization effects related to inner-shell ionization.

  18. The distribution, atmospheric transfer, and assessment of krypton-85; Distribution, transfert atmospherique et bilan du krypton-85

    Energy Technology Data Exchange (ETDEWEB)

    Pannetier, R [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-06-01

    Techniques for sampling and measuring krypton-85 have been developed which allowed to determine its geographical distribution. From its use as a tracer, an evaluation of the air masses which cross over the subtropical fronts has been derived. Besides, the stratospheric character of air pollution by krypton-85 at the level of the antarctic soil has been shown out. Levels of krypton-85 seem to point out to an underestimation of the assessment of nuclear explosion fission energies as adopted by the United Nations Scientific committee on the effects of atomic radiation and emphasize the need to set limits as soon as possible to the amounts of krypton-85 released to the atmosphere by fuel-reprocessing plants. (author) [French] La mise au point de techniques de prelevement et de mesure du krypton-85 atmospherique a permis de determiner sa repartition geographique. De son utilisation comme traceur on deduit une evaluation des masses d'air qui traversent les fronts subtropicaux. Par ailleurs, le caractere stratospherique de la pollution de l'air par le krypton-85 au niveau du sol antarctique est mis en evidence. Le bilan du krypton-85 semble reveler une sous-estimation du bilan des energies de fission des explosions adopte par le Comite scientifique des Nations Unies et souligne la necessite de limiter des que possible les quantites de krypton-85 rejetees dans l'atmosphere par les usines de traitement de combustibles irradies. (auteur)

  19. Capture and immobilization of krypton-85

    International Nuclear Information System (INIS)

    Whitmell, D.S.; Geens, L.; Penzhorn, R.D.; Smith, M.J.S.

    1985-01-01

    It may become necessary to contain the krypton-85 released from nuclear fuel during reprocessing in order to reduce the exposure to the local population and the radioactive background throughout the world. A brief description is given of studies being carried out in the Indirect Action Programme. The separation of krypton from other off-gases by cryogenic distillation in the presence of oxygen is being studied at SCK/CEN Mol, together with the behavior of ozone in the distillation column. Two processes for the immobilization of krypton in solid forms have been successfully developed and demonstrated. At KfK Karlsruhe, krypton is encapsulated in vitrified zeolites; at AERE Harwell, krypton is immobilized within a metallic matrix. These processes offer excellent gas retention and either could be adopted for a reprocessing plant

  20. Discovery of a Probable Nova in M81 and Photometry of Three M81 Novae

    Science.gov (United States)

    Hornoch, K.; Errmann, R.; Carlisle, Ch.; Vaduvescu, O.

    2015-02-01

    We report the discovery of a probable nova in M81 on a co-added 1600-s narrow-band H-alpha CCD image taken with the 2.5-m Isaac Newton Telescope (INT) + WFC at La Palma under ~1.6" seeing on 2015 Jan.

  1. Ultra-Trace Analysis of Krypton-85

    International Nuclear Information System (INIS)

    Daerr, H.; Kalinowski, M.; Kohler, M.; Sahling, P.

    2010-01-01

    To strengthen the efficiency and effectiveness of nuclear safeguards for detecting undeclared nuclear material and activities we propose to use the radioactive krypton isotope Krypton-85 as a tracer for clandestine plutonium production. The main idea is to detect inexplicable atmospheric Kr85 concentration using the novel technology atom trap trace analysis (ATTA) in order to detect an undeclared reprocessing facility. The Additional Protocol (INFCIRC/540, 1997) establishes the possibility to take environmental samples. Krypton-85 has a combination of unique features which makes it an ideal tracer for plutonium separation activities anywhere in the world. It is always generated along with plutonium and 99.9% remains within the fuel cladding. Due to its half-life of 10.76 years, significant amounts of krypton-85 still remain in the spent fuel even after long cooling times. Krypton is not removed from the atmosphere by any processes like chemical reactions or wash-out. Furthermore, there are no other relevant sources of krypton-85 besides of reprocessing. The novel technology of atom trap trace analysis (ATTA) has been demonstrated by the physics group at Argonne National Laboratory in 1999. This is an ultra-sensitive trace analysis technique able to detect single krypton atoms. We are setting up an ATTA apparatus in our laboratory, which is designed to fulfill all requirements to detect clandestine plutonium production. Our goal is to determine Krypton-85 concentration of one liter samples of atmospheric air with an analysis time of 3 hours. This sample volume reduction is a significant step, since one liter can be taken as a grab sample by sucking it directly into pre-evacuated bottles at atmospheric pressure. The small samples size and the short analysis time of ATTA will make it possible to use krypton-85 as a tracer for clandestine plutonium production with routine operation. (author)

  2. Atomic structure investigation of ionized krypton

    International Nuclear Information System (INIS)

    Kotze, P.B.

    1981-12-01

    The experimental lifetimes of ionized Krypton are discussed. Theoretical, the Coulomb approximation proves to be a reliable tool for the performance of calculations in Krypton II, where in general good agreement between experimental and theoretical lifetimes is reached, but its vulnerability is exposed in the case of Krypton III, where only results concerning levels with a 4p 3 ( 4 S 0 ) parent core can be obtained. Although the single configuration Hartree-Fock approximation turns out to be an adequate way of obtaining wave functions of excited states in Krypton III, cancellation effects resulting from configuration-interaction mixing, make the calculated transition probabilities in Krypton II less reliable. Previous work on configuration-interaction effects in the spectrum of Krypton II (El 76a, El 76b) reveals that good agreement between experimental and theoretical results can be obtained. A systematic theoretical analysis based on the multi-configurarion Hartree-Fock approximation to account for configuration-interaction effects should contribute a great deal to the existing knowledge of the energy spectra of ionized atoms

  3. Kilo-electron-volt neutron capture cross sections of the krypton isotopes

    International Nuclear Information System (INIS)

    Walter, G.; Leugers, B.; Kappeler; Bao, Z.Y.; Reffo, G.; Fabbri, F.

    1986-01-01

    The neutron capture cross sections of the stable krypton isotopes were determined in the energy interval from 4 to 250 keV using a C/sub 6/D/sub 6/-detector system in conjunction with the time-of-flight technique. The energy resolution of the measurement was 4% at 20 keV and 6% at 100 keV, and the experimental uncertainties were typically 6 to 10%. The measurements were complemented by statistical model calculations of all krypton isotopes in the mass range 78 < A < 86 to also obtain reliable cross sections for the unstable nuclei /sup 79,81,85/Kr. These calculations were based on local systematics for all relevant parameters, and the results were estimated to show uncertainties of 20 to 25%. Maxwellian average cross sections were calculated for kT=30 keV

  4. Hyperfine spectra of the radioactive isotopes 81Kr and 85Kr

    International Nuclear Information System (INIS)

    Cannon, B.D.

    1993-01-01

    Isotope shifts and hyperfine constants are reported for the radioactive isotopes 81 Kr and 85 Kr and the stable isotope 83 Kr. The previously unreported nuclear moments of 81 Kr were determined to be μ I =-0.909(4) nuclear magneton and Q=+0.630(13) b from the hyperfine constants. This work increases the number of transitions for which 85 Kr hyperfine constants and isotope shifts have been measured from 1 to 4. The hyperfine anomaly for krypton reported in the previous measurement of 85 Kr hyperfine constants [H. Gerhardt et al., Hyperfine Interact. 9, 175 (1981)] is not supported by this work. The isotope shifts and hyperfine constants of 83 Kr measured in this work are in excellent agreement with previous work. Saturation spectroscopy was used to study transitions from krypton's metastable 1s 5 state to the 2p 9 , 2p 7 , and 2p 6 states. In saturation spectra, different line shapes were observed for the even- and odd-mass krypton isotopes. This even- versus odd-line-mass shape difference can be explained using the large cross section that has been reported for collisional transfer of the 1s 5 state excitation between krypton atoms. Two-color two-photon laser-induced fluorescence was used to measure the hyperfine spectra of the 1s 5- 4d 4 ' transition using the 2p 9 state as the intermediate state. This technique proved to be more sensitive than saturation spectroscopy

  5. Adsorption of krypton from helium by low temperature charcoal

    International Nuclear Information System (INIS)

    Cooper, M.H.; Simmons, C.R.; Taylor, G.R.

    1975-01-01

    Adsorption of krypton from helium by charcoal at temperatures from -100 0 C to -140 0 C was experimentally investigated to verify adsorption system design methods and to determine effects of regeneration for the Gas Purification System of the Liquid-Metal Fast Breeder Reactor. Helium with two krypton concentrations, traced by krypton-85 at 0.0044 μCi/cm 3 , was passed through a 1/2-inch diameter, three-inch long trap packed with coconut charcoal. Breakthrough curves were measured by continuously recording the activity of the effluent gas using a sampler with a krypton-85 detection limit of about 5 x 10 -7 μCi/cm 3 . Experimental breakthrough curves with continuous feed for both concentrations and for superficial gas velocities of 5 to 28 cm/sec were closely fitted when the pore diffusion term was omitted from the Anzelius linear equilibrium adsorption model indicating that the adsorption process for this system was controlled by gas phase mass transport kinetics. Adsorption capacities determined in these experiments at -140 0 C agreed closely with published data. A discontinuity, however, was observed in the krypton adsorption coefficient between -100 and -120 0 C. This discontinuity may be caused by capillary condensation of krypton in the charcoal pores. Breakthrough times for pulse experiments at 400 ppM (vol.) krypton concentration were several times greater than breakthrough for continuous feed experiments at equivalent conditions. The differences in breakthrough times indicate that the adsorption isotherms are non-linear in this concentration range. Regeneration experiments showed that purging with helium at room temperature for 16 hours was inadequate, since lower breakthrough times were obtained after this treatment. Regeneration under vacuum at 100 0 C or 200 0 C for 16 hours resulted in satisfactory regeneration (i.e., no reduction in breakthrough times occurred in subsequent runs). (U.S.)

  6. Krypton recovery from reprocessing off-gases by cryogenic distillation

    International Nuclear Information System (INIS)

    Geens, L.P.; Goossens, W.R.A.; Marien, J.

    1987-01-01

    With the financial support of the C.E.C., krypton recovery by cryogenic distillation in presence of oxygen was investigated. Both oxygen and ozone behavior in the cryodistillation unit were observed. The ozone decay in the rectification column was studied in absence and in presence of a radiation source. Additionally a demonstration run with krypton-85 was performed. Experiments with different oxygen concentrations up to 21% volume in the feed gas were carried out. The oxygen was enriched up to 85% volume in a zone between the krypton layer and the entrance of the rectification column. No oxygen was found in the bottom product. On the other hand, the ozone accumulated in that bottom product. The decay of ozone in the bottom liquid was measured in absence and in presence of a 500 Ci thulium-170 source. Without the radiation source, it took almost 30 days to observe a decay from 0.90% volume to 0.45% volume. The decay rate decreased with decreasing ozone concentration. In presence of the 500 Ci thulium-170, a constant decay rate of 0.24% volume per day was measured. Finally, a demonstration run with 100 Ci krypton-85 was performed in the cryodistillation unit, with air as feed gas. The krypton-85 was fed at a concentration of 30 mCih -1 until the total krypton inventory of the rectification column amounted to 40-45 Ci. The active run had a duration of 900 hours, during which no operational problems occurred. (orig.)

  7. Process and device for the adsorptive separation of krypton from a krypton/nitrogen gas mixture

    International Nuclear Information System (INIS)

    Ringel, H.; Messler, M.

    1985-01-01

    The gas mixture flows through an adsorption column, which is filled with a means of adsorbing Krypton and nitrogen. The adsorption column is desorbed after adsorption of the gas components by a gaseous flushing material, which flows through the adsorption column in the same direction as the gas mixture. In order to achieve a high degree of separation, the adsorption material is loaded with nitrogen and Krypton from the gas inlet, where Krypton is only absorbed over part of the length of the whole column by the adsorption material. The part of the length is such that on desorption of the adsorption column with the flushing material at first only nitrogen and later only Krypton is obtained at the outlet of the adsorption column. (Waste gas system of a reprocession plant). (orig./HP) [de

  8. A comparison of positron-emitting blood pool imaging agents

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Kulprathipanja, S.; Evans, G.; Elmaleh, D.

    1979-01-01

    The three agents, 11 C-carboxyhaemoglobin, 68 Ga-transferrin and 68 Ga-labelled red cells have been compared in dogs to assess their relative merits for blood-pool imaging. For 1 h following administration of each agent, periodic blood samples were withdrawn for counting in a NaI (Tl) well counter while conventional two-dimensional images were obtained simultaneously on the Massachusetts General Hospital positron camera. Count rates in regions about the heart, liver and spleen were obtained for each image. The disappearance of blood activity as shown from the results of counting the blood samples and from the counting rates in regions about the heart was found to be identical within experimental error for the three agents. In the liver and spleen regions, the highest count rates were obtained with 68 Ga-transferrin and the lowest with 68 Ga-labelled red cells; count rates in these regions with labelled red cells were virtually constant throughout the 1 h study. It may be concluded that with the exceptions noted above, the three agents are approximately equivalent for blood-pool imaging. (author)

  9. Krypton laser membranotomy in the treatment of dense premacular hemorrhage.

    Science.gov (United States)

    Chen, Yung-Jen; Kou, His-Kung

    2004-12-01

    Neodymium:YAG (Nd:YAG) laser and argon laser membranotomy have been used in patients with premacular hemorrhage to drain premacular blood into the vitreous cavity and rapidly clear the hemorrhage. However, the Nd:YAG laser appears to be difficult to use, and argon laser energy may be more likely to be absorbed by the ocular media. We performed a study to evaluate the safety and effectiveness of krypton laser membranotomy in selected cases of premacular hemorrhage. Sixteen patients (17 eyes) with dense premacular hemorrhage for 2 weeks or less were enrolled from April 1998 to February 2004. The causes of premacular hemorrhage were proliferative diabetic retinopathy (PDR) in 12 eyes, Valsalva retinopathy in 3 eyes, leukemia in I eye and retinal arterial macroaneurysm in I eye. Krypton laser was used to create a membranotomy on the sloping edge of the premacular hemorrhage. Five eyes with PDR were treated with inferior panretinal photocoagulation and laser membranotomy simultaneously. After intravitreal dispersion of premacular blood, fundus examination was performed in all eyes and fluorescein angiography in five eyes to evaluate retinal damage. All eyes had visual improvement within 2 weeks postoperatively. No retinal damage was seen at the site of membranotomy in any eye. No eye needed vitrectomy postoperatively during a mean follow-up duration of 18.6 months. Krypton laser membranotomy appears to be a safe and simple alternative procedure for treating selected cases of premacular hemorrhage. Further trials are necessary to evaluate its benefit.

  10. Method for separating krypton isotopes

    International Nuclear Information System (INIS)

    Porter, J.T.

    1980-01-01

    Methods and apparatus for separating krypton isotopes utilizing low temperature selective infrared excitation of 85krypton difluoride in an isotopic compound mixture. Multiphoton ir excitation and uv excitation techniques are used, as well as cryogenic matrix isolation and inert buffer gas isolation techniques

  11. 18F-FDG-labeled red blood cell PET for blood-pool imaging: preclinical evaluation in rats.

    Science.gov (United States)

    Matsusaka, Yohji; Nakahara, Tadaki; Takahashi, Kazuhiro; Iwabuchi, Yu; Nishime, Chiyoko; Kajimura, Mayumi; Jinzaki, Masahiro

    2017-12-01

    Red blood cells (RBCs) labeled with single-photon emitters have been clinically used for blood-pool imaging. Although some PET tracers have been introduced for blood-pool imaging, they have not yet been widely used. The present study investigated the feasibility of labeling RBCs with 18 F-2-deoxy-2-fluoro-D-glucose ( 18 F-FDG) for blood-pool imaging with PET. RBCs isolated from venous blood of rats were washed with glucose-free phosphate-buffered saline and labeled with 18 F-FDG. To optimize labeling efficiency, the effects of glucose deprivation time and incubation (labeling) time with 18 F-FDG were investigated. Post-labeling stability was assessed by calculating the release fraction of radioactivity and identifying the chemical forms of 18 F in the released and intracellular components of 18 F-FDG-labeled RBCs incubated in plasma. Just after intravenous injection of the optimized autologous 18 F-FDG-labeled RBCs, dynamic PET scans were performed to evaluate in vivo imaging in normal rats and intraabdominal bleeding models (temporary and persistent bleeding). The optimal durations of glucose deprivation and incubation (labeling) with 18 F-FDG were 60 and 30 min, respectively. As low as 10% of 18 F was released as the form of 18 F-FDG from 18 F-FDG-labeled RBCs after a 60-min incubation. Dynamic PET images of normal rats showed strong persistence in the cardiovascular system for at least 120 min. In the intraabdominal bleeding models, 18 F-FDG-labeled RBC PET visualized the extravascular blood clearly and revealed the dynamic changes of the extravascular radioactivity in the temporary and persistent bleeding. RBCs can be effectively labeled with 18 F-FDG and used for blood-pool imaging with PET in rats.

  12. Preferential site occupancy observed in coexpanded argon-krypton clusters

    International Nuclear Information System (INIS)

    Lundwall, M.; Bergersen, H.; Lindblad, A.; Oehrwall, G.; Svensson, S.; Bjoerneholm, O.; Tchaplyguine, M.

    2006-01-01

    Free heterogeneous argon-krypton clusters have been produced by coexpansion and investigated by means of x-ray photoelectron spectroscopy. By examining cluster surface and bulk binding energy shifts, relative intensities, and peak widths, we show that in the mixed argon-krypton clusters the krypton atoms favor the bulk and argon atoms are pushed to the surface. Furthermore, we show that krypton atoms in the surface layer occupy high-coordination sites and that heterogeneous argon-krypton clusters produced by coexpansion show the same surface structure as argon host clusters doped with krypton. These observations are supported by site-dependent calculations of chemical shifts

  13. Study on the possibility of sea-disposal of krypton-85

    International Nuclear Information System (INIS)

    Dalen, A. van; Vons, L.H.; Verkerk, B.

    1980-01-01

    Results of a feasibility study, performed under a contract with the Commission of the European Communities, regarding technical and radiological aspects of sea-disposal of all krypton-85 retained in a large fuel reprocessing facility, are presented. The design of a double-walled, essentially spherical container is described that provides both double containment of the compressed gas and permanent 'disposable' radiation shielding. Three sizes have been studied, i.e. with internal volumes of 0.01, 0.05 and 0.1 m 3 , each designed to hold 0.1 m 3 (STP) of krypton, and each containing approximately 400 TBq of 85 Kr per 0.001 m 3 sphere volume. This results in an internal heat production of 17.5 kW/m 3 . Calculations of temperatures and stresses that would result from the conditions of the required fire test for B(U) transport packages showed that the design would allow the containers to pass this test. Radiological consequences have been considered for disposal of petabecquerel amounts of 85 Kr as a function of undamaged container lifetime on the sea bed. Finally, an indication is given of the necessary amendments to the London Convention in order to allow sea-disposal of these large amounts of radioactive krypton. (author)

  14. The use of Kr-81m in ventilation imaging

    International Nuclear Information System (INIS)

    Pommet, R.; Therain, F.

    1982-01-01

    Radioactive gases are very useful in the study of pulmonary disorders because they allow an assessment of regional lung function. The most widely used radioactive gases are Xe-133 and, more recently, Kr-81m. This paper is a review of the physical characteristics of Kr-81m, its production from the parent Rb-81, the different methods to produce Rb-81, the different types of generators which can be used in hospitals, and the clinical applications of pulmonary ventilation imaging. The paper suggests that Kr-81m offers several advantages over previous methods that used Xe-133 due to its improved spatial resolution, its capacity to provide superimposable ventilation and perfusion images in multiple projections, and its total lung dose which is ten times lower than that of Xe-133

  15. The dynamics of the spiral galaxy M81

    International Nuclear Information System (INIS)

    Visser, H.C.D.

    1978-01-01

    A detailed comparison of the observations of the spiral galaxy M81 with the density-wave theory for tightly-wound spirals is presented. In particular, hydrogen-line observations are compared with the nonlinear density-wave theory for the gas with the aim of constructing a density-wave model for the spiral galaxy M81

  16. Krypton tagging velocimetry of an underexpanded jet.

    Science.gov (United States)

    Parziale, N J; Smith, M S; Marineau, E C

    2015-06-01

    In this work, we present the excitation/emission strategy, experimental setup, and results of an implementation of krypton tagging velocimetry (KTV). KTV is performed as follows: (i) seed a base flow with krypton; (ii) photosynthesize metastable krypton atoms with a frequency-doubled dye laser to form the tagged tracer; (iii) record the translation of the tagged metastable krypton by imaging the laser-induced fluorescence (LIF) that is produced with an additional dye laser. The principle strength of KTV, relative to other tagging velocimetry techniques, is the use of a chemically inert tracer. KTV results are presented for an underexpanded jet of three mixtures of varying Kr/N2 concentration. It is demonstrated that KTV can be used in gas mixtures of relatively low krypton mole fraction (0.5% Kr/99.5% N2), and the KTV data from that experiment are found to be in good agreement with an empirical fit found in the literature. We find that KTV is useful to perform instantaneous velocity measurements with metastable krypton as a chemically inert, dilute, long-lifetime tracer in gas-phase flows.

  17. Radioactive kryptonates in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    The term ''radioactive Kryptonates'' is used for substances into which atoms or ions of the radioactive nuclide 85 Kr are incorporated. The basis of the use of radioactive Kryptonates in analytical chemistry is that during a chemical reaction the crystalline lattice of the kryptonated carrier is destroyed, the carrier consumed, and the radioactive krypton released (radio-release method). Analysis can be made with a calibration curve or by comparison with a standard. Radio-release methods with the aid of radioactive Kryptonates as analytical reagents are very useful for the analysis of environmental samples, e.g. for the determination of air pollutants (ozone, sulphur dioxide, fluorine, hydrogen fluoride, mercury); and water pollutants (oxygen, dichromate, vanadium, hydrochloric acid, sulphur dioxide). (author)

  18. Optimum allocation of imaging time and minimum detectable activity in dual isotope blood pool subtraction indium-111 platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Horowitz, S.F.; Goldsmith, S.J.; Fuster, V.

    1984-01-01

    Indium-111 labeled platelet imaging is a tool for detection of thrombus formation in vascular spaces. Dual isotope blood pool subtraction may help differentiate focal platelet accumulation from blood pool activity. This study used a computer model to calculate the minimum excess-to-blood pool platelet ratio (EX/BP) and the optimum dual isotope imaging times under varied conditions of lesion size. The model simulated usual human imaging doses of 500 μCi of In-111 platelets and 5mCi of Tc-99m labeled RBCs giving a reference cardiac blood pool region (100cc) of 10000 cpm for Tc-99m and 500 cpm for In-111. The total imaging time was fixed at 20 minutes, while the two isotope imaging times (TIn/TTc) were varied, as were the simulated lesion size (cc) and EX/BP. The relative error of the excess counts was calculated using propagation of error theory. At the critical level of detection, where the excess lesion counts equal 3 times the standard deviation, the optimum TIn/TTc and minimum Ex/BP were determined for each lesion size. For the smallest lesion size (0.1cc), the minimum detectable EX/BP ratio was 1.6, with the best TIn/TTC ratio of 18/2 minutes, and for large lesions, an EX/BP of 0.1, with a TIn/TTc of 16/4. This model provides an estimate of the sensitivity and optimizes imaging times in dual isotope subtraction platelet imaging. The model is adaptable to varying isotope doses, total imaging times and lesion size. This information will be helpful in future in- vivo imaging studies of intravascular thrombi in humans

  19. Krypton retention on solid adsorbents

    International Nuclear Information System (INIS)

    Monson, P.R. Jr.

    1980-01-01

    Radioactive krypton-85 is released to the atmosphere in the off-gas from nuclear reprocessing plants. Three main methods have been suggested for removal of krypton from off-gas streams: cryogenic distillation; fluorocarbon absorption; and adsorption on solid sorbents. Use of solid adsorbents is the least developed of these methods, but offers the potential advantages of enhanced safety and lower operating costs. An experimental laboratory program was developed that will be used to investigate systematically many solid adsorbents (such as zeolites, i.e., mordenites) for trapping krypton in air. The objective of this investigation is to find an adsorbent that is more economical than silver-exchanged mordenite. Various physical and chemical characteristics such as adsorption isotherms, decontamination factors, co-adsorption, regeneration, and the mechanism and kinetics of noble gas adsorption were used to characterize the adsorbents. In the experimental program, a gas chromatograph using a helium ionization detector was used to measure the krypton in air before and after the adsorbent bed. This method can determine directly decontamination factors greater than 100

  20. Krypton-85 pollution and atmospheric electricity

    International Nuclear Information System (INIS)

    Harrison, R.G.; ApSimon, H.M.

    1994-01-01

    Krypton-86 is a chemically inert radioactive gas present in the atmosphere, concentrations of which have been greatly increased by nuclear reprocessing and weapons testing since 1945. The long half-life (10.7 yr), allows the gas to mix thoroughly in the atmosphere. Ionization caused by krypton-85 increases the electrical conductivity of atmospheric air. Further increases in krypton-85 emissions seem inevitable. The increase in air conductivity due to release of krypton-85 will vary with height, and be larger over the oceans than over the land. Increases in conductivity will produce uncertain effects on atmospheric phenomena, so changes are compared in magnitude with other factors perturbing the conductivity, such as combustion aerosol burdens, volcanic eruptions and nuclear weapons testing. Conductivity changes are expected to have the greatest significance for meteorological phenomena close to the source. (Author)

  1. The jet of the Low Luminosity AGN of M81

    Directory of Open Access Journals (Sweden)

    Alberdi A.

    2013-12-01

    Full Text Available In this contribution, we summarize our main results of a big campaign of global VLBI observations of the AGN in M81 (M81* phase-referenced to the radio supernova SN 1993J. Thanks to the precise multi-epoch and multi-frequency astrometry, we have determined the normalized core-shift of the relativistic jet of M81* and estimated both the magnetic field and the particle density at the jet base. We have also found evidence of jet precession in M81* coming from the systematic time evolution of the jet orientation correlated with changes in the overall flux density.

  2. Phase analysis in gated blood pool tomography. Detection of accessory conduction pathway

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro (Kanazawa Univ. (Japan). School of Medicine)

    1984-02-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome.

  3. Charge state distribution of ionic kryptons after photoionization

    International Nuclear Information System (INIS)

    Cai Xiaohong

    1992-01-01

    Monochromatic X-rays from the 2.3 GeV synchrotron at University Bonn (Germany) are employed for inner shell excitation of krypton. Various ionic kryptons and a number of electrons are produced due to photoionization. In order to study the equilibrium charge state distribution of ionic kryptons, a time of flight mass spectrometer is set up and used to measure the resulting ionic charge spectra with photo energies near the L 1 - , L 2 - and L 3 - absorption edges of krypton. The energy dependence of relative probabilities is presented

  4. The releases of krypton-85 and tritium to the environment and tritium to krypton-85 ratios as source indicators

    International Nuclear Information System (INIS)

    Schroeder, K.J.P.; Roether, W.

    1975-01-01

    More than 95% of the krypton-85 that is at present observed in the environment on a global scale originates from the combined releases following nuclear-power generation and plutonium production, while atmospheric fusion-bomb testing accounts for the same percentage of the global tritium. The global inventories at the end of 1973 were 55 MCi (estimated uncertainty +- 10%) of krypton-85, and 2900 MCi (+- 25%) of tritium. From the excess of the global krypton-85 inventory over the amounts accounted for by the sources other than plutonium production, it is concluded that 130 tonnes of plutonium-239 have been produced up to 1970. Pronounced fractionation occurs between atmosphere and hydrosphere, in the sense that the concentration of krypton-85 is lowered, and that of tritium (being overwhelmingly in the form of a water molecule, HTO) is greatly increased, in the hydrosphere. Largely as a consequence of this fractionation, the environmental tritium to krypton-85 ratios cover a wide range, with values lowest in the troposphere (typical order of magnitude 10 -1 Ci/Ci) and highest in continental surface water (of the order of 10 5 ). Preliminary oceanic krypton-85 data are reported, which indicate that the concentration decrease with depth in the ocean is very similar for both nuclides. Effluents from nuclear power reactors and reprocessing plants have tritium to krypton-85 ratios that do not differ markedly from those found at present in the troposphere; on the other hand, the very high ratios that are typical of the hydrosphere may offer opportunities of detecting such effluents in the hydrosphere on the basis of tritium to krypton-85 ratios. Considerable uncertainties in the ratios of the effluents have, however, to be anticipated, arising from varying, and fluctuating, fractionation between the two nuclides in the release processes. (author)

  5. Storage characteristics of multiple-donor pooled red blood cells compared to single-donor red blood cell units.

    Science.gov (United States)

    Mathur, Aabhas; Chowdhury, Raquibul; Hillyer, Christopher D; Mitchell, W Beau; Shaz, Beth H

    2016-12-01

    Each unit of blood donated is processed and stored individually resulting in variability in the amount of red blood cells (RBCs) collected, RBC properties, and the 24-hour posttransfusion RBC survivability. As a result, each unit differs in its ability to deliver oxygen and potentially its effects on the recipient. The goal of this study was to investigate the storage of pooled RBCs from multiple donors in comparison to control standard RBC units. Two units of irradiated, leukoreduced RBCs of same ABO, D, E, C, and K antigen phenotype were collected from each of five donors using apheresis. One unit from each donor was pooled in a 2-L bag and remaining units were used as controls. After being pooled, RBCs were separated in five bags and stored at 4°C along with the controls. Quality indexes were measured on Days 2, 14, and 28 for all the units. Adenosine triphosphate assays for both pooled and controls showed a slight decrease from Day 2 to Day 28 (pooled/control from 5.22/5.24 to 4.35/4.33 µmol/g hemoglobin [Hb]). 2,3-Diphosphoglycerate was successfully rejuvenated for all RBC units on Day 28 (pooled 11.46 µmol/g Hb; control 11.86 µmol/g Hb). The results showed a nonsignificant difference between pooled and control units, with a general trend of lower standard deviation for pooled units when compared to controls. Pooled units have reduced unit-to-unit variability. Future exploration of their immunogenicity is required before using pooled units for transfusion. © 2016 AABB.

  6. Immobilization technology for krypton in amorphous zeolite

    International Nuclear Information System (INIS)

    Takusagawa, Atsushi; Ishiyama, Keiichi

    1989-01-01

    Radioactive krypton recovered from the offgas of a reprocessing plant requires long-term storage on the order of 100 years. Immobilization technology for krypton into amorphous zeolite 5A is considered one of the best methods for long-term storage. In this report, conditions for immobilization treatment and stability of amorphous zeolite 5A loaded krypton against heat, radiation and water are discussed, and a treatment system using this technology is described. (author)

  7. Solubility of krypton in hydrofracture grout at elevated pressures

    International Nuclear Information System (INIS)

    Fitzgerald, C.L.; Mailen, J.C.

    1982-01-01

    The solubilities of krypton in water, simulated waste solution, and simulated grout at about 25 0 C and to pressures of 150 atm have been determined. The results of these studies show that preliminary calculations of krypton solubility based on the aqueous component of the hydrofracture grout were overly pessimistic. The volume of noble gas generated annually by the reference reprocessing plant would be soluble in the annual hydrofracture grout injection at ORNL at about 10 atm. The amount of krypton in the gas phase would depend on the amount of air in the hydrofracture grout mixture. At 34 atm, and with a small air volume relative to the injected krypton, the krypton would constitute about 30% of the gas bubbles. The disposal of krypton via injection with hydrofracture grout seems to be a viable process. The next logical steps would be to determine the krypton diffusion rate at injection conditions, and possibly to perform a test injection. At present, the schedule for future work is uncertain since funds for this project have been reduced significantly

  8. Patterns of disturbed myocardial perfusion in patients with coronary artery disease. Regional myocardial perfusion in angina pectoris

    International Nuclear Information System (INIS)

    Selwyn, A.P.; Forse, G.; Fox, K.; Jonathan, A.; Steiner, R.

    1981-01-01

    Fifty patients who presented with angina pectoris were studied to examine the disturbances of regional myocardial perfusion during stress. Each patient underwent 16-point precordial mapping of the ECG during an exercise test, and coronary and left ventricular angiography. Regional myocardial perfusion was assessed using an atrial pacing test and a short-lived radionuclide, krypton-81m. Eleven patients had negative exercise tests and uniform increases in myocardial activity of krypton-81m of 98 +/- 18.0% during pacing. Ten patients performed 30,000-43,000 J in positive exercise tests. These patients showed abnormal coronary anatomy and increases in myocardial activity of krypton-81m to remote and jeopardized myocardium at the onset of pacing. However, further pacing produced a decrease in activity in the affected segment of 68.0 +/- 9.0% accompanied by ST-segment depression and angina. Twelve patients achieved 26,000-32,000 J in positive exercise tests and had significant coronary artery disease. Atrial pacing produced increased activity of krypton-81m to remote myocardium. The jeopardized segment at first showed no change and then a decrease in regional activity of krypton-81m (89.0 +/- 17%) accompanied by ST-segment depression and chest pain. Seventeen patients achieved only 7000-22,000 J in positive exercise tests. These patients showed abnormal coronary anatomy and developed decreases in regional activity of krypton-81m to the affected segment of myocardium starting at the onset of atrial pacing and decreasing by 88 +/- 0 7.0% below control. We conclude that different patterns of disturbed myocardial distribution of krypton-81m are present during stress-induced ischemia in patients with coronary artery disease. There was a close temporal relationship between these disturbances and ST-segment depression

  9. Potential for beneficial use of krypton-85

    International Nuclear Information System (INIS)

    Tingey, G.L.; Jensen, G.A.; McClanahan, E.D.; Lytle, J.M.; Rising, K.R.

    1983-03-01

    Large quantities of krypton-85 (about 42 MCi) are contained in stored power-reactor fuels and about 1 MCi/year in fuels processed at each of the Savannah River and Hanford defense fuel-processing plants. This nuclear byproduct could be a significant material resource if used in specialized applications. Recently a technique for implanting krypton in a growing sputter-deposited metallic film has been developed. This yields a stable, high-concentration source of krypton-85 which may have applications for small power generators. Metal deposits containing up to 14 at. % have been prepared that would give a heat source of 0.9 W/cm 3 if fully enriched krypton-85 were implanted. Potential applications for up to 10-W batteries include power for runway lighting and other specialized military applications in remote locations, power for telephone or radiocommunications in the far North, and power for monitoring equipment for tracking animals. Krypton-85 has the advantage of being environmentally the most acceptable heat-producing radioisotope available for power production. 1 figure

  10. Development of krypton-85 measurement in ocean samples by beta counting and use of the krypton-85 as a tracer in oceanography

    International Nuclear Information System (INIS)

    Ternon, Jean-Francois

    1990-01-01

    Krypton-85 present in the environment has essentially an anthropogenic origin, and the knowledge of the evolution of its concentration in the atmosphere, and of its mode of penetration in the ocean by gaseous exchange at the surface, and its bio-geochemical stability in the environment make it a potential tool to trace movements of water masses in the ocean. This research thesis aims at being a contribution to the implementation of an experimental device which would allow very low concentrations of krypton-85 in the ocean to be measured. After a presentation of the general context, the author reports the development of the two last steps of krypton-85 measurement: the separation of krypton by gas chromatography, and the measurement of krypton-85 by low-level radioactive counting. Then, the author reports the study of the use of krypton-85 as a tracer in oceanography, and notably highlights its similarities with CFC which are widely used to study ocean circulation [fr

  11. Reliable Reporting for Massive M2M Communications with Periodic Resource Pooling

    DEFF Research Database (Denmark)

    Madueño, Germán Corrales; Stefanovic, Cedomir; Popovski, Petar

    2014-01-01

    This letter considers a wireless M2M communication scenario with a massive number of M2M devices. Each device needs to send its reports within a given deadline and with certain reliability, e.g., 99.99%. A pool of resources available to all M2M devices is periodically available for transmission...... to guarantee the desired reliability of the report delivery within the deadline. The fact that the pool of resources is used by a massive number of devices allows to base the dimensioning on the central limit theorem. The results are interpreted in the context of LTE, but they are applicable to any M2M...

  12. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  13. AMINO ACID BLOOD POOL OF CHILDREN WITH ALLERGIC DISEASES

    Directory of Open Access Journals (Sweden)

    Shmulich O. V.

    2014-01-01

    Full Text Available The amino acid blood pool of children with atopic dermatitis, bronchial asthma, urticaria, angioedema was investigated. The variability of blood plasma amino acid content (tryptophan, histidine, tyrosine, cysteine, methionine was observed. The changes of histidine and tryptophan levels might be connected with the formation of biogenic amines, such as histamine, serotonine, with take part in the development of allergic reactions and inflammatory processes in organism.

  14. Confirmation of Faint Dwarf Galaxies in the M81 Group

    Science.gov (United States)

    Chiboucas, Kristin; Jacobs, Bradley A.; Tully, R. Brent; Karachentsev, Igor D.

    2013-11-01

    We have followed up on the results of a 65 deg2 CFHT/MegaCam imaging survey of the nearby M81 Group searching for faint and ultra-faint dwarf galaxies. The original survey turned up 22 faint candidate dwarf members. Based on two-color HST ACS/WFC and WFPC2 photometry, we now confirm 14 of these as dwarf galaxy members of the group. Distances and stellar population characteristics are discussed for each. To a completeness limit of M_{r^{\\prime }} = -10, we find a galaxy luminosity function slope of -1.27 ± 0.04 for the M81 Group. In this region, there are now 36 M81 Group members known, including 4 blue compact dwarfs; 8 other late types including the interacting giants M81, NGC 3077, and M82; 19 early type dwarfs; and at least 5 potential tidal dwarf galaxies. We find that the dSph galaxies in M81 appear to lie in a flattened distribution, similar to that found for the Milky Way and M31. One of the newly discovered dSph galaxies has properties similar to the ultra-faint dwarfs being found in the Local Group with a size Re ~ 100 pc and total magnitude estimates M_{r^{\\prime }} = -6.8 and MI ~ -9.1.

  15. Two dimensional polar display of cardiac blood pool SPECT

    International Nuclear Information System (INIS)

    Honda, Norinari; Machida, Kikuo; Mamiya, Toshio; Takahashi, Taku; Takishima, Teruo; Hasegawa, Noriko; Hashimoto, Masanori; Ohno, Ken

    1989-01-01

    A new method of ECG gated cardiac blood pool SPECT to illustrate the left ventricular (LV) wall motion in a single static image, two dimensional polar display (2DPD), was described. Circumferential profiles of the difference between end diastolic and end systolic short axis images of the LV were displayed in a similar way to the bull's eye plot of 201 Tl myocardial SPECT. The diagnoses by 2DPDs agreed with those by cinematic displays of ECG gated blood pool SPECT in 74 out of 84 segments (85.5%) of abnormal motion, and 155 out of 168 segments (80.3%) of normal motion. It is concluded that 2DPD can evaluate regional wall motion by a single static image in a significant number of patients, and is also useful in comparing with the bull's eye image of 201 Tl myorcardial SPECT. (orig.)

  16. Value of lateral blood pool imaging in patients with suspected stress fractures of the tibia.

    Science.gov (United States)

    Mohan, Hosahalli K; Clarke, Susan E M; Centenara, Martin; Lucarelli, Amanda; Baron, Daniel; Fogelman, Ignac

    2011-03-01

    To critically evaluate the use of lateral blood pool imaging in athletes with lower limb pain and with a clinical suspicion of stress fracture. Two experienced nuclear medicine physicians evaluated 3-phase bone scans using 99mTc-methylene diphosphonate performed in 50 consecutive patients referred from a specialist sports injury clinic for suspected tibial stress fracture. The vascularity to the tibia as seen on the blood pool (second phase) images in the anterior/posterior views was compared with the lateral/medial view assessments. Stress fractures were presumed to be present when on the delayed images (third phase) there was a focal or fusiform area of increased tracer uptake involving the tibial cortex. Shin splints which are a recognized cause of lower limb pain in athletes mimicking stress fracture were diagnosed if increased tracer uptake was seen extending along the posterior tibial surface with no significant focal or fusiform area of uptake within this. Inter-reviewer agreement for the assessment of vascularity was also assessed using Cohen's Kappa scores. Twenty-four stress fractures in 24 patients and 66 shin splints in 40 patients were diagnosed. In 18 patients stress fracture and shin splints coexisted. In 10 patients no tibial pathology was identified. Of the 24 patients diagnosed with stress fractures, lateral/medial blood pool imaging was superior in the assessment of blood pool activity (P tibial stress fractures, lateral views of the tibia provide the optimal method for evaluation of vascularity. Prospective studies with quantitative or semi-quantitative assessment of skeletal vascularity could provide supplementary information relating to the pathophysiology of stress fractures, for example, the time scale of vascular changes after a tibial stress fracture, and potentially could have clinical relevance as to the assessment of the severity of stress fractures and their prognosis.

  17. Self-Assembled Nanomicelles as MRI Blood-Pool Contrast Agent.

    Science.gov (United States)

    Babič, Andrej; Vorobiev, Vassily; Xayaphoummine, Céline; Lapicorey, Gaëlle; Chauvin, Anne-Sophie; Helm, Lothar; Allémann, Eric

    2018-01-26

    Gadolinium-loaded nanomicelles show promise as future magnetic resonance imaging (MRI) contrast agents (CAs). Their increased size and high gadolinium (Gd) loading gives them an edge in proton relaxivity over smaller molecular Gd-complexes. Their size and stealth properties are fundamental for their long blood residence time, opening the possibility for use as blood-pool contrast agents. Using l-tyrosine as a three-functional scaffold we synthesized a nanostructure building block 8. The double C18 aliphatic chain on one side, Gd-1,4,7,10-tetraazacyclododecane-1-4-7-triacetic acid (Gd-DO3A) with access to bulk water in the center and 2 kDa PEG on the hydrophilic side gave the amphiphilic properties required for the core-shell nanomicellar architecture. The self-assembly into Gd-loaded monodispersed 10-20 nm nanomicelles occurred spontaneously in water. These nanomicelles (Tyr-MRI) display very high relaxivity at 29 mm -1  s -1 at low field strength and low cytotoxicity. Good contrast enhancement of the blood vessels and the heart together with prolonged circulation time in vivo, makes Tyr-MRI an excellent candidate for a new supramolecular blood-pool MRI CA. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Desublimation of krypton from a noncondensable carrier gas

    International Nuclear Information System (INIS)

    Eby, R.S.

    1978-09-01

    A study was conducted to obtain column concentration profiles and point buildup rates for a cold trap freezing out krypton from a nitrogen carrier gas stream and to compare those experimentally obtained profiles with profiles generated from a theoretical model. Profiles were obtained over a range of flow conditions from 0.14 to 1.06 standard cubic feet per minute, krypton feed gas concentrations varied from 5.2 to 13.5%, and cold trap operating temperatures from -281 to -312 0 F. Gamma scintillation techniques using tracer amounts of krypton-85 provided the major analytical tool employed in the investigation. Data obtained from the experiments indicate that if values for the density and thermal conductivity of the krypton frost are known, the model can accurately predict krypton loading profiles in the cold trap. The frost density and frost conductivity appear to be functions of the freeze-out temperature and condensable krypton concentration. A discussion of cold trapping theory, a description of the experimental apparatus and tests performed, and an explanation of the usefulness of the model as a design tool for engineering use are included

  19. CONFIRMATION OF FAINT DWARF GALAXIES IN THE M81 GROUP

    Energy Technology Data Exchange (ETDEWEB)

    Chiboucas, Kristin [Gemini Observatory, 670 North A' ohoku Pl, Hilo, HI 96720 (United States); Jacobs, Bradley A.; Tully, R. Brent [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96821 (United States); Karachentsev, Igor D., E-mail: kchibouc@gemini.edu, E-mail: bjacobs@ifa.hawaii.edu, E-mail: tully@ifa.hawaii.edu, E-mail: ikar@luna.sao.ru [Special Astrophysical Observatory (SAO), Russian Academy of Sciences, Nizhnij Arkhyz, Karachai-Cherkessian Republic 369167 (Russian Federation)

    2013-11-01

    We have followed up on the results of a 65 deg{sup 2} CFHT/MegaCam imaging survey of the nearby M81 Group searching for faint and ultra-faint dwarf galaxies. The original survey turned up 22 faint candidate dwarf members. Based on two-color HST ACS/WFC and WFPC2 photometry, we now confirm 14 of these as dwarf galaxy members of the group. Distances and stellar population characteristics are discussed for each. To a completeness limit of M{sub r{sup '}}= -10, we find a galaxy luminosity function slope of –1.27 ± 0.04 for the M81 Group. In this region, there are now 36 M81 Group members known, including 4 blue compact dwarfs; 8 other late types including the interacting giants M81, NGC 3077, and M82; 19 early type dwarfs; and at least 5 potential tidal dwarf galaxies. We find that the dSph galaxies in M81 appear to lie in a flattened distribution, similar to that found for the Milky Way and M31. One of the newly discovered dSph galaxies has properties similar to the ultra-faint dwarfs being found in the Local Group with a size R{sub e} ∼ 100 pc and total magnitude estimates M{sub r{sup '}}= -6.8 and M{sub I} ∼ –9.1.

  20. Treatment of Proliferative Diabetic Retinopathy: a Comparison of Krypton Green, Krypton Yellow and Krypton Red Lasers%三种波长氪离子激光治疗增殖期糖尿病性视网膜病变的疗效比较

    Institute of Scientific and Technical Information of China (English)

    王洁; 李军; 韩素珍

    2011-01-01

    目的 比较氪绿激光、氪黄激光和氪红激光治疗增殖期糖尿病性视网膜病变(PDR)的疗效.方法 PDR患者167例243只眼,随机分为氪绿激光、氪黄激光和氪红激光治疗组,行标准全视网膜光凝.比较三组患眼视力、新生血管的变化.结果 三组患者视力比较差异无显著意义(P>0.05).新生血管消退比较,氪绿激光组与氪红激光组比较差异无显著意义(P>0.05).氪黄激光组与氪绿激光组、氪红激光组比较差异有显著意义(P<0.05).结论 氪绿激光、氪黄激光和氪红激光对PDR均有治疗作用,氪绿激光和氪红激光的疗效较好.%Objective To investigate the therapeutic effect of the krypton green, krypton yellow or krypton red laser in the treatnent of proliferative diabetic retinopathy(PDR) .Methods Two hundred and forty-three eyes of 167 PDR patients were assigned randomly to receive either krypton green, krypton yellow or krypton red laser treatment, to investigate the changes in the vision and neovessels.Results There was no statistical difference among krypton green, krypton yellow and krypton red laser treatment for PDR(P>0. 05)in visual improvement, and also between krypton green with krypton red laser in neovessels loss, but there was statistical difference between krypton yellow with krypton green or krypton red laser in it.Conclusions The three kinds of krypton lasers all have therapeutic effect on PDR, but the krypton green and krypton red lasers should be preferred.

  1. The study of radiochemical separation methods on gaseous Fission product krypton-88

    International Nuclear Information System (INIS)

    Yang Zhihong; Zhang Shengdong; Yang Lei; Ding Youqian; Sun Hongqing; Ma Peng

    2012-01-01

    Half-life of krypton-88 is 2.84 hours, high fission yields and a relatively large gamma branching ratio is had. The gas is short-lived fission products in burnup measurements. Only New fission products can extract from extraction in gas of fissile irradiation target. But krypton-88 with krypton-85, krypton-87, xenon -135, and xenon-138 is coexisted together, thus radiochemical separation must quickly taken. selected the irradiation time is 1-2 hours and cooling time is best 2 hours for sample preparation, krypton and xenon were separated using activated carbon adsorption, the ratio of krypton and xenon were measured by gamma spectroscopy. Then according to the ratio of krypton-85 and xenon-125 count rate coefficient around separation were calculated yield of krypton and decontamination factor of xenon and the final the yield of krypton-85 is calculated. (authors)

  2. Application of blood-pool agents in visualization of peripheral vessels

    International Nuclear Information System (INIS)

    Giovagnoni, A.; Catalano, C.

    2007-01-01

    Effective arterial imaging is essential in patients with peripheral arterial disease (PAD) in whom a revascularization procedure is planned. Digital subtraction angiography (DSA) has traditionally been regarded as the gold standard for imaging in peripheral arterial disease, but this technique is subject to certain limitations, such as the risks of adverse reactions associated with arterial catheterization and iodinated contrast agents. Contrast-enhanced magnetic resonance angiography is now recommended as an effective and useful imaging technique in peripheral arterial disease, since it offers high enhanced contrast between blood and stationary tissue and fast acquisition times. However, extracellular gadolinium contrast agents rapidly diffuse into the interstitial spaces, and thus are suitable only for first-pass imaging. This limitation can be overcome by the use of blood-pool (intravascular) contrast agents, such as gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany), which are retained within the blood vessels and hence facilitate both first-pass and steady-state imaging with high spatial resolution. Blood-pool agents, therefore, offer improved imaging, particularly of distal vessels, compared with extracellular contrast agents. Examples of first-pass and steady-state imaging with gadofosveset are presented. (orig.)

  3. Atmospheric krypton-85 during 1962 and 1963

    Energy Technology Data Exchange (ETDEWEB)

    Ehhalt, D.; Muennich, K. O.; Roether, W.; Schoelch, J.; Stich, W.

    1963-11-15

    The krypton-85 found in the atmosphere presumably originates from two different sources, namely fission bomb tests and processing of burned-out fuel elements from nuclear reactors. This paper discusses the impact of the sources of krypton in the atmosphere in greater detail.

  4. Formation of actinide hexafluorides at ambient temperatures with krypton difluoride

    International Nuclear Information System (INIS)

    Asprey, L.B.; Eller, P.G.; Kinkead, S.A.

    1986-01-01

    A second low-temperature agent, krypton difluoride, for generating volatile plutonium hexafluoride is reported (dioxygen difluoride is the only other reported agent). Plutonium hexafluoride is formed at ambient or lower temperature by the treatment of various solid substrates with krypton difluoride. Volatilization of uranium and neptunium from solid substrates using gaseous krypton difluoride is also reported for the first time. The formation of actinide hexafluorides has been confirmed for the reaction of krypton difluoride in anhydrous HF with UO 2 and with uranium and neptunium fluorides at ambient temperatures. Treatment of americium dioxide with krypton difluoride did not yield americium hexafluoride under the conditions studied. 15 references, 2 figures

  5. Physical properties and heat transfer characteristics of materials for krypton-85 storage

    International Nuclear Information System (INIS)

    Christensen, A.B.

    1977-09-01

    Krypton-85 decay results in heat generation, and the subsequent temperature increase in the krypton-85 storage media must be evaluated. This report compiles the physical properties of krypton and of potential krypton-85 storage materials which are required to calculate the maximum temperature developed during storage. Temperature calculations were made for krypton-85 stored as a gas or immobilized solid in steel storage cylinders. The effects of krypton-85 loading, cylinder radius, storage media properties, and exterior cooling on storage temperature were shown

  6. The atmosphere of Mars - Detection of krypton and xenon

    Science.gov (United States)

    Owen, T.; Biemann, K.; Biller, J. E.; Lafleur, A. L.; Rushneck, D. R.; Howarth, D. W.

    1976-01-01

    Krypton and xenon have been discovered in the Martian atmosphere with the mass spectrometer on the second Viking lander. Krypton is more abundant than xenon. The relative abundances of the krypton isotopes appear normal, but the ratio of xenon-129 to xenon-132 is enhanced on Mars relative to the terrestrial value for this ratio. Some possible implications of these findings are discussed.

  7. Analysis of HARP TPC krypton data

    CERN Document Server

    Dydak, F

    2004-01-01

    This memo describes the procedure which was adopted to equalize the response of the 3972 pads of the HARP TPC, using radioactive 83mKr gas. The results obtained from the study of reconstructed krypton clusters in the calibration data taken in 2002 are reported. Two complementary methods were employed in the data analysis. Compatible results were obtained for channel-to-channel equalization constants. An estimate of the overall systematic uncertainty was derived.

  8. Partitioning of krypton-85 in liquid scintillation cocktail

    International Nuclear Information System (INIS)

    Hohorst, F.A.; Sherlock, M.A.

    1994-12-01

    Krypton is one of the noble gases. As such, it forms compounds only with exceptionally strong oxidizing agents. The concentration of krypton in air is 1.139 parts per million by volume. In general, its behavior is best described as that of an ideal gas. Krypton-85 is the longest lived of the common radioactive noble gases with a half life of 10.72 years. Gamma radiation at 513.990 keV has an intensity of only 0.434%. Most decay is β - emission with a maximum energy of 687.0 keV and an average energy of 251.4 keV. The analytical chemistry of krypton-85 is driven by these factors. High concentrations may be gamma counted directly. Low levels are typically determined by more sensitive techniques such as liquid scintillation counting (LSC) where detection limits on the order of 1 picocurie (pCi) are routinely achieved. For a 5 standard cubic centimeter (scc) sample, this represents a concentration of 0.2 pCi/scc, well below the DOE Air Immersion Derived Concentration Guideline (G) of 3 pCi/scc. As a gas, krypton in a sealed LSC vial distributes itself between the liquid phase and the gas phase. Some past work has used gamma counting at levels many orders of magnitude greater than those now achievable by LSC to study the distribution of krypton. This effect is of interest in the analytical chemistry of krypton-85 because geometrical considerations influence how much of the material in the gas phase decays generating particles which then impact the liquid phase where they may be counted

  9. Enrichment Conditions of Krypton Onto Activated Carbons%活性炭对氪的富集条件

    Institute of Scientific and Technical Information of China (English)

    陈莉云; 曾宝珠; 张昌云; 武山; 刘龙波; 杨静; 韦冠一

    2012-01-01

    In order to monitor radioactive krypton distribution in the environment, active charcoal is used to enrich krypton before the sample can be submitted to further laboratory analysis. The importance and method of krypton enrichment were presented. The absorption behavior of krypton by charcoal was analyzed. The experimental setup was designed to investigate effects of working temperature, linear velocities, partial-pressure of krypton on the enrichment of krypton by charcoal. The micro-structure parameters of the absorbing material to characterize its absorbing property was used, and the experimental data with theoretical analysis to conclude that for CF-1450 was fitted. The saturation absorption capacity at 191 K is 32. 9 mL/g.%从环境监测角度,叙述了开展活性炭对氪富集条件研究的重要意义.以氪在活性炭上的动态吸附实验为基础,研究了活性炭、温度、气体线流速和氪的分压对氪富集的影响,利用吸附材料的微结构,通过吸附理论模型拟合实验数据,得到CF-1450活性炭在191 K下对氪的饱和吸附量为32.9 mL/g.

  10. Simultaneous detection of xenon and krypton in equine plasma by gas chromatography-tandem mass spectrometry for doping control.

    Science.gov (United States)

    Kwok, Wai Him; Choi, Timmy L S; So, Pui-Kin; Yao, Zhong-Ping; Wan, Terence S M

    2017-02-01

    Xenon can activate the hypoxia-inducible factors (HIFs). As such, it has been allegedly used in human sports for increasing erythropoiesis. Krypton, another noble gas with reported narcosis effect, can also be expected to be a potential and less expensive erythropoiesis stimulating agent. This has raised concern about the misuse of noble gases as doping agents in equine sports. The aim of the present study is to establish a method for the simultaneous detection of xenon and krypton in equine plasma for the purpose of doping control. Xenon- or krypton-fortified equine plasma samples were prepared according to reported protocols. The target noble gases were simultaneously detected by gas chromatography-triple quadrupole mass spectrometry using headspace injection. Three xenon isotopes at m/z 129, 131, and 132, and four krypton isotopes at m/z 82, 83, 84, and 86 were targeted in selected reaction monitoring mode (with the precursor ions and product ions at identical mass settings), allowing unambiguous identification of the target analytes. Limits of detection for xenon and krypton were about 19 pmol/mL and 98 pmol/mL, respectively. Precision for both analytes was less than 15%. The method has good specificity as background analyte signals were not observed in negative equine plasma samples (n = 73). Loss of analytes under different storage temperatures has also been evaluated. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Separation of krypton from carbon dioxide and oxygen with molecular sieves

    International Nuclear Information System (INIS)

    Forsberg, C.W.

    1976-01-01

    Molecular sieves were investigated to separate 1 percent mixtures of krypton in gas streams of a few percent oxygen and 90+ percent carbon dioxide. Such a system will be required to concentrate the krypton gas between radioactive krypton off-gas cleanup systems such as KALC (Krypton Absorption in Liquid Carbon Dioxide) and any krypton gas bottling station. Linde 5A molecular sieves were found capable of selectively removing the CO 2 from the gas stream while partially separating the oxygen from the krypton; i.e., effecting a three-component gas separation. This use of molecular sieves differs from standard practice in two respects. First, the bulk of the gas (greater than 90 percent) is removed by molecular sieves rather than the normal practice of using molecular sieves to remove trace impurities. Second, in a single bed two separations occur simultaneously, CO 2 from other gases and krypton from oxygen. The use of molecular sieves for separating krypton and carbon dioxide is superior to alternatives such as CO 2 freezeout and chemical traps when there are only moderate gas flows and there is a need for very high reliability and ease of maintenance

  12. Update and improvement of the global krypton-85 emission inventory

    International Nuclear Information System (INIS)

    Ahlswede, Jochen; Hebel, Simon; Ross, J. Ole; Schoetter, Robert; Kalinowski, Martin B.

    2013-01-01

    Krypton-85 is mainly produced in nuclear reactors by fission of uranium and plutonium and released during chopping and dissolution of spent fuel rods in nuclear reprocessing facilities. As noble gas it is suited as a passive tracer for evaluation of atmospheric transport models. Furthermore, research is ongoing to assess its quality as an indicator for clandestine reprocessing activities. This paper continues previous efforts to compile a comprehensive historic emission inventory for krypton-85. Reprocessing facilities are the by far largest emitters of krypton-85. Information on sources and calculations used to derive the annual krypton-85 emission is provided for all known reprocessing facilities in the world. In addition, the emission characteristics of two plants, Tokai (Japan) and La Hague (France), are analysed in detail using emission data with high temporal resolution. Other types of krypton-85 sources are power reactors, naval reactors and isotope production facilities. These sources contribute only little or negligible amounts of krypton-85 compared to the large reprocessing facilities. Taking the decay of krypton-85 into account, the global atmospheric inventory is estimated to about 5500 PBq at the end of 2009. The correctness if the inventory has been proven by meteorological simulations and its error is assumed to be in the range of a few percent. - Highlights: ► Krypton-85 is mainly produced in nuclear reactors and released during reprocessing. ► Krypten-85 can be possibly used as an indicator for clandestine reprocessing. ► This work provides an up-to-date global krypton-85 emission inventory. ► The inventory includes emissions from all possible artificial sources.

  13. Radioactivity 85Kr in krypton enriched with light isotope

    International Nuclear Information System (INIS)

    Kuz'minov, V.V.; Novikov, V.M.; Pomanskij, A.A.

    1992-01-01

    85 Kr content in krypton enriched with 78 Kr is measured within the frames of experiment for search of binary position decay and conversion of atomic electron into 78 Kr. Voluminous activity in krypton enriched up to 98% 78 Kr equal to 0.206 -0.004 +0.001 Bq/L is obtained which is by 4000 less as compared to natural krypton. 7 refs.; 1 fig.; 1 tab

  14. Solid state storage of radioactive krypton in a silica matrix

    International Nuclear Information System (INIS)

    Tingey, G.L.; Lytle, J.M.; Gray, W.J.; Wheeler, K.R.

    1980-12-01

    The feasibility of loading a low density SiO 2 glass with krypton for storage of radioactive 85 Kr has been demonstrated by studies using non-radioactive krypton. A 96% SiO 2 glass with 28% porosity was heated at an elevated pressure of Kr gas to a temperature of 850 to 900 0 C and held at that temperature to sinter the glass-krypton composite to a density of about 2 g/cm 3 . A krypton content of 30 cm 3 of Kr(STP)/cm 3 of glass has been demonstrated when loading pressures of 140 MPa are used. Krypton release rates from the glass are lower than reported for any other waste form considered currently. At 420 0 C a diffusion parameter, D/r 0 2 , of 8.66 x 10 -13 min -1 was determined which leads to a total release of 0.7% of the krypton in 10 years. Release rates increase moderately with increasing temperature up to 600 0 C and increase rapidly above 600 0 C. The lower loading pressures (about 40 MPa) may appear to yield a more favorable product from the point of view of krypton release than the high pressures. Advantages and disadvantages of the technique are given in the conclusions section

  15. The distribution, atmospheric transfer, and assessment of krypton-85

    International Nuclear Information System (INIS)

    Pannetier, R.

    1968-06-01

    Techniques for sampling and measuring krypton-85 have been developed which allowed to determine its geographical distribution. From its use as a tracer, an evaluation of the air masses which cross over the subtropical fronts has been derived. Besides, the stratospheric character of air pollution by krypton-85 at the level of the antarctic soil has been shown out. Levels of krypton-85 seem to point out to an underestimation of the assessment of nuclear explosion fission energies as adopted by the United Nations Scientific committee on the effects of atomic radiation and emphasize the need to set limits as soon as possible to the amounts of krypton-85 released to the atmosphere by fuel-reprocessing plants. (author) [fr

  16. Spectra of heliumlike krypton from tokamak fusion test reactor plasmas

    International Nuclear Information System (INIS)

    Bitter, M.; Hsuan, H.; Bush, C.; Cohen, S.; Cummings, C.J.; Grek, B.; Hill, K.W.; Schivell, J.; Zarnstorff, M.; Smith, A.; Fraenkel, B.

    1993-04-01

    Krypton has been injected into ohmically-heated TFTR plasmas with peak electron temperatures of 6 key to study the effects of krypton on the plasma performance and to investigate the emitted krypton line radiation, which is of interest for future-generation tokamaks such as ITER, both as a diagnostic of the central ion temperature and for the control of energy release from the plasma by radiative cooling. The emitted radiation was monitored with a bolometer array, an X-ray pulse height analysis system, and a high-resolution Johann-type crystal spectrometer; and it was found to depend very sensitively on the electron temperature profile. Satellite spectra of heliumlike krypton, KrXXXV, near 0.95 Angstrom including lithiumlike, berylliumlike and boronlike features were recorded in second order Bragg reflection. Radiative cooling and reduced particle recycling at the plasma edge region were observed as a result of the krypton injection for all investigated discharges. The observations are in reasonable agreement with modeling calculations of the krypton ion charge state distribution including radial transport

  17. High-Power Krypton Hall Thruster Technology Being Developed for Nuclear-Powered Applications

    Science.gov (United States)

    Jacobson, David T.; Manzella, David H.

    2004-01-01

    The NASA Glenn Research Center has been performing research and development of moderate specific impulse, xenon-fueled, high-power Hall thrusters for potential solar electric propulsion applications. These applications include Mars missions, reusable tugs for low-Earth-orbit to geosynchronous-Earth-orbit transportation, and missions that require transportation to libration points. This research and development effort resulted in the design and fabrication of the NASA-457M Hall thruster that has been tested at input powers up to 95 kW. During project year 2003, NASA established Project Prometheus to develop technology in the areas of nuclear power and propulsion, which are enabling for deep-space science missions. One of the Project-Prometheus-sponsored Nuclear Propulsion Research tasks is to investigate alternate propellants for high-power Hall thruster electric propulsion. The motivation for alternate propellants includes the disadvantageous cost and availability of xenon propellant for extremely large scale, xenon-fueled propulsion systems and the potential system performance benefits of using alternate propellants. The alternate propellant krypton was investigated because of its low cost relative to xenon. Krypton propellant also has potential performance benefits for deep-space missions because the theoretical specific impulse for a given voltage is 20 percent higher than for xenon because of krypton's lower molecular weight. During project year 2003, the performance of the high-power NASA-457M Hall thruster was measured using krypton as the propellant at power levels ranging from 6.4 to 72.5 kW. The thrust produced ranged from 0.3 to 2.5 N at a discharge specific impulse up to 4500 sec.

  18. A new 99mTc-red blood cell labeling procedure for cardiac blood pool imaging: Clinical results

    International Nuclear Information System (INIS)

    Kelbaek, H.; Buelow, K.; Aldershvile, J.; Moegelyang, J.; Nielsen, S.L.; Copenhagen Univ.

    1989-01-01

    The first clinical results of a new 99m Tc-red blood cell labeling procedure avoiding cell centrifugation are presented. One ml heparinized blood samples were incubated with small amounts of a stannous kit. By titration studies, ideal quantities of sodium hypochlorite for oxidation of extracellular tin and of EDTA as stabilizer of the label were found. The Cl - concentration and pH of the labeled blood were acceptable, and EDTA increased labeling yield and stability determined in vitro by a few percent. The new procedure gave a slightly higher labeling yield than a current technique using centrifugation of cells. Labeling efficiency expressed as cell bound/total activity was 96.6%±1.3% in healthy subjects and 95.5%±2.2% in cardiac patients and remained high for 2 h after reinjection. The biological halflife of labeled cells following the new procedure was 11-12 h rendering it suitable for serial determinations of radionuclide cardiography. (orig.)

  19. Determination of low levels of krypton in helium by gas chromatography

    International Nuclear Information System (INIS)

    Evans, D.L.; Mukherji, A.K.

    1980-01-01

    Krypton-helium mixture was used as an adsorbate for surface area measurement--. The surface area measurements depend on the accuracy with which the krypton concentration is known. Generally gas tanks supplied by Union Carbide provide a nominal value of 0.1% krypton in helium. The surface area measurements require, however, that the krypton concentraion be known to +- 0.001% or better. A standard plot of krypton volume in microliters vs the area under the curve as measured by a planimeter using the helium detector and Molecular Sieve 5A column was obtained. Results with a thermal conductivity detector using Molecular Sieve 5A and Carbon Molecular Sieve are also given. Low levels of krypton in helium can be measured with precision using either a helium or a thermal conductivity detector with Molecular Sieve 5A or Carbon Molecular Sieve columns. 2 figures, 1 table

  20. Update and improvement of the global krypton-85 emission inventory.

    Science.gov (United States)

    Ahlswede, Jochen; Hebel, Simon; Ross, J Ole; Schoetter, Robert; Kalinowski, Martin B

    2013-01-01

    Krypton-85 is mainly produced in nuclear reactors by fission of uranium and plutonium and released during chopping and dissolution of spent fuel rods in nuclear reprocessing facilities. As noble gas it is suited as a passive tracer for evaluation of atmospheric transport models. Furthermore, research is ongoing to assess its quality as an indicator for clandestine reprocessing activities. This paper continues previous efforts to compile a comprehensive historic emission inventory for krypton-85. Reprocessing facilities are the by far largest emitters of krypton-85. Information on sources and calculations used to derive the annual krypton-85 emission is provided for all known reprocessing facilities in the world. In addition, the emission characteristics of two plants, Tokai (Japan) and La Hague (France), are analysed in detail using emission data with high temporal resolution. Other types of krypton-85 sources are power reactors, naval reactors and isotope production facilities. These sources contribute only little or negligible amounts of krypton-85 compared to the large reprocessing facilities. Taking the decay of krypton-85 into account, the global atmospheric inventory is estimated to about 5500 PBq at the end of 2009. The correctness if the inventory has been proven by meteorological simulations and its error is assumed to be in the range of a few percent. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Diagnostic significance of lung ventilation study with sup(81m)Kr gas

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Ito, Yasuhiko; Ohtsuka, Nobuaki; Muranaka, Akira; Yokobayashi, Tsuneo

    1979-01-01

    Lung ventilation study was performed on 43 patients by the continuous inhalation of sup(81m)Kr gas from a 81 Rb-sup(81m)Kr generator (Nihon Mediphysics Inc. Hyogo Japan). The patients were measured in a sitting position using a scintillation camera in conjunction with a data processor. In 37 cases, scintigraphic findings were compared with those of sup(99m)Tc-MAA images. We discussed the ventilation/perfusion mismatching cases, especially in those of the pulmonary arterial abnormarity and lung cancer. In some of the discrepancy between ventilation and perfusion, nuclear angiography with sup(99m)Tc-HSA was performed. The following results were obtained by those studies. 1) The distribution of sup(81m)Kr gas within the lung is considered proportional to regional ventilation because of a short half life of sup(81m)Kr (13 seconds). 2) The ventilation image with sup(81m)Kr gas was clearly visualized because of the lower gamma-ray energy and much accumulation of activity. 3) Combined use of ventilation-perfusion scintigraphy and nuclear angiography often gave us new additional informations about the pathophysiological condition of lung. 4) In mismatching cases of lung cancer, perfusion was usually more impaired than ventilation. (author)

  2. Krypton retention on solid adsorbents

    International Nuclear Information System (INIS)

    Monson, P.R. Jr.

    1981-08-01

    Over a dozen prospective adsorbents for krypton were studied and evaluated with respect to adsorption capacity and cost for dissolver off-gas streams from nuclear reprocessing plants. Results show that, at subambient temperature (-40 0 to -80 0 C), the commercially available hydrogen mordenite has sufficient adsorptive capacity to be the most cost-effective material studied. Silver mordenite has a higher capacity for krypton retention, but is 50 times more expensive than hydrogen mordenite. The results indicate that a solid adsorbent system is feasible and competitive with other developing systems whih utilize fluorocarbon absorption and cryogenic distillation

  3. Beam-foil level lifetimes in krypton III

    International Nuclear Information System (INIS)

    Coetzer, F.J.; Kotze, P.B.; Westhuizen, P. van der

    1982-01-01

    The radiative lifetimes of levels in doubly-ionized Krypton have been measured after foil excitation of a beam of Krypton particles in the wavelength range 120-500 nm. The results are compared with the experimental values obtained by Fink et al., as well as theoretical values resulting from Coulomb (C.A.) and single configuration Hartree-Fock (H.F.) calculations. (orig.)

  4. Discovery of an Apparent Nova in M81

    Science.gov (United States)

    Hornoch, K.; Alfaro, M. Diaz; Ordonez-Etxeberria, I.; Vaduvescu, O.

    2015-01-01

    We report the discovery of an apparent nova in M81 on a co-added 1600-s narrow-band H-alpha CCD image taken with the 2.5-m Isaac Newton Telescope (INT) + WFC at La Palma under ~2.4" seeing on 2015 Jan. 15.126 UT.

  5. Environmental consequences of atmospheric krypton-85

    International Nuclear Information System (INIS)

    Boeck, W.L.

    1978-01-01

    This project examines the thesis that atmospheric background ionization is relevant to the understanding of weather. Projections of future world-wide use of nuclear energy imply that sufficient krypton-85 will be produced and may be released to significantly alter the natural ionization background. The scope of the project includes an assessment of krypton-85 on the electrical aspects of the atmosphere as well as the consequences of an altered electrical state of the atmosphere. The results of a first approximation model for the effects of krypton-85 on the atmosphere show that the electric field at the surface of the ocean would be reduced by about 25 percent and at a continental station by about 15 percent. At about two kilometers altitude, the electric field would be reduced by about 14 percent over the oceans and 16 percent over the land. The effects decrease quickly with increasing altitude. Analytical studies of the equations for fair weather atmospheric electricity yield solutions suitable for the interpretation of time dependent phenomena with periods longer than a few seconds. A brief analysis shows that a perfect assessment is not necessary to make an error-free decision regarding krypton-85 control measures. From the viewpoint of a decision-maker, those aspects that could swing the decision from one alternative to another are priority areas for analysis

  6. Solid sources of krypton-85; Sources solides de krypton-85; Tverdye istochniki kriptona-85; Fuentes solidas de cripton-85

    Energy Technology Data Exchange (ETDEWEB)

    Puig, J R; Sandier, J [Centre d' Etudes Nucleaires de Saclay (France)

    1962-01-15

    Krypton-85, a {beta}-emitter with a long half-life and low biological hazard, has considerable industrial potentialities. It is difficult, however, to manufacture sources since the element occurs in gaseous form and cannot be chemically fixed. The authors describe a method of krypton-fixation in a macromolecular matrix formed by mass polymerization of a liquid monomer containing krypton; they also give an account of the preparation of two types of source produced in this way-one enclosed in polystyrene, the other in polyvinyl acetate. Such sources lose krypton; the activity of the first decreases by 8 % daily, that of the second by 3 % daily. These apparent decays enable the diffusion coefficients of krypton in these polymers to be calculated. Diffusion appears to be prevented by the cross-linkages which exist in the polymers. (author) [French] Le krypton-85, emetteur {beta} de longue periode et de faible danger biologique, offre des avantages importants pour une utilisation industrielle. Mais la fabrication de sources est difficile du fait que cet element se presente sous forme gazeuse et qu'il ne peut etre fixe chimiquement. Les auteurs exposent une methode de fixation du krypton dans une matrice macromoleculaire formee par la polymerisation en masse d'un monomere liquide contenant le krypton, et decrivent les preparations de deux types de sources realisees sur ce principe - l'une enfermee dans du polystyrene, l'autre dans de l'acetate de polyvinyle. Les sources ainsi obtenues laissent echapper du krypton; leur activite diminue de 8% par jour pour la premiere et de 3% par jour pour la seconde. Ces decroissances apparentes permettent de calculer les coefficients de diffusion du krypton dans ces polymeres. Celle-ci parait empechee par les liaisons de pontage existant dans le polymere. (author) [Spanish] El cripton-85 es un emisor beta de periodo largo y poco peligroso desde el punto de vista biologico, que ofrece considerables ventajas para su empleo en la

  7. [Effect of krypton-containing gas mixture on Japanese quail embryo development].

    Science.gov (United States)

    Kussmaul', A R; Gur'eva, T S; Dadasheva, O A; Pavlov, N B; Pavlov, B N

    2008-01-01

    Investigated were effects of gas mixture with up to 3.0 kgs/cm2 of krypton on the embryonic development of domesticated Japanese quail (Coturnix coturnix japonica dom.). Results demonstrated absence of a serious krypton effect on Japanese quail embryos. Development of embryos proceeded in due course; morphometrically the experimental embryos were essentially similar to controls. It should be noted that despite exposure to acute hypoxic hypoxia during the initial 12 hours of development in the krypton-containing gas mixture, viability of quail embryos was high enough which can be ascribed to the krypton protective action. Besides, an additional experiment showed that krypton partial pressure of 5-5.5 kgs/cm2 produces the narcotic effect on adult Japanese quails.

  8. 81mKr scintigraphic evaluation of hemodynamics in gynecologic malignancies under condition of Angiotensin II-induced hypertension

    International Nuclear Information System (INIS)

    Sumi, Yukiharu; Ozaki, Yutaka; Amemiya, Ken; Kyogoku, Shinsuke; Shirakata, Akihiro; Tamamoto, Fumihiko; Katayama, Hitoshi; Utsuno, Hiroshi; Kubota, Takeyoshi

    1992-01-01

    Transcatheter arterial infusion chemotherapy is one of the most useful therapeutic procedures for gynecologic malignancies. Although several reports have been published about Angiotensin II-induced hypertension chemotherapy and the efficacy of the method, there have been no reports to evaluate an application for gynecologic malignancies. We evaluated the usefulness of the method for gynecologic malignancies demonstrating the changes of hemodynamics of the tumor using 81m Kr scintigraphy. Thirteen patients with pathologically confirmed gynecologic malignancies were evaluated by angiography and continuous infusion of 81m Kr via the catheter with and without Angiotensin II. At first, continuous infusion of 81m Kr was performed under the superselective catheterization of the uterine artery. The radioactivities in the ROI were counted. Then, withdrew the catheter from the uterine artery to the internal iliac artery, and again continuously infused 81m Kr and counted the radioactivities in the same ROI. Finally, keeping the catheter in the internal iliac artery, Angiotensin II and 81m Kr were infused simultaneously. And counted the radioactivities. The radioactivities were highest when the catheter tip was placed in uterine arteries and lowest when the catheter tip was placed in internal iliac arteries. But radioactivities in the ROIs were definitely increased when Angiotensin II was used, even if the catheter tip was keeping in the internal iliac arteries. The optimal catheter position of transcatheter arterial chemotherapy for gynecologic malignancies is at proximal uterine artery. Since Angiotensin II-induced hypertension may increase blood flow of tumors, it seems to have indication for postoperative cases, highly advanced cases and cases with difficulties to perform superselective catheterization. From our experience, we believe chemotherapeutic agents must be administrated via catheter within 3 minutes after infusion of Angiotensin II. (author)

  9. Facility for the separation of krypton and recuperation of xenon

    International Nuclear Information System (INIS)

    Boell-Djoa, S.H.

    1977-01-01

    A facility is described by means of which the fission inert gases krypton 85 and xenon from spent fuel particles can be separated by fractionated freezing-out and subsequent distillation to such an extent that the xenon contains less than 1 ppb krypton 85. Then, in accordance with the stringent regulations, the krypton can be conveyed to definitive storage in special bottles, whereas the xenon can be released for industrial uses. (orig.) [de

  10. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1984-10-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous krypton-85 air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where krypton-85 was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State of the art krypton-85 sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of krypton-85. 3 references, 3 figures, 1 table

  11. Cylindrical ionization chamber with compressed krypton

    International Nuclear Information System (INIS)

    Kuz'minov, V.V.; Novikov, V.M.; Pomanskii, A.A.; Pritychenko, B.V.; Viyar, J.; Garcia, E.; Morales, A.; Morales, J.; Nunes-Lagos, R.; Puimedon, J.; Saens, K.; Salinas, A.; Sarsa, M.

    1993-01-01

    A cylindrical ionization chamber with a grid is used to search for double positron decay and atomic electron conversion to a positron in 78 Kr. Krypton is the working gas material of the chamber. The spectrometric characteristics of the chamber filled with krypton and xenon are presented. The energy resolution is 2.1% for an energy of 1.84 MeV (the source of γ-quanta is 88 Y) when the chamber is filled with a mixture of Kr+0.2% H 2 under a pressure of 25 atm

  12. Krypton laser photocoagulation induces retinal vascular remodeling rather than choroidal neovascularization.

    Science.gov (United States)

    Behar-Cohen, F; Benezra, D; Soubrane, G; Jonet, L; Jeanny, J C

    2006-08-01

    The purpose of this study is to analyze the retina and choroid response following krypton laser photocoagulation. Ninety-two C57BL6/Sev129 and 32 C57BL/6J, 5-6-week-old mice received one single krypton (630 nm) laser lesion: 50 microm, 0.05 s, 400 mW. On the following day, every day thereafter for 1 week and every 2-3 days for the following 3 weeks, serial sections throughout the lesion were systematically collected and studied. Immunohistology using specific markers or antibodies for glial fibrillary acidic protein (GFAP) (astrocytes, glia and Muller's cells), von Willebrand (vW) (vascular endothelial cells), TUNEL (cells undergoing caspase dependent apoptosis), PCNA (proliferating cell nuclear antigen) p36, CD4 and F4/80 (infiltrating inflammatory and T cells), DAPI (cell nuclei) and routine histology were carried out. Laser confocal microscopy was also performed on flat mounts. Temporal and spatial observations of the created photocoagulation lesions demonstrate that, after a few hours, activated glial cells within the retinal path of the laser beam express GFAP. After 48 h, GFAP-positive staining was also detected within the choroid lesion center. "Movement" of this GFAP-positive expression towards the lasered choroid was preceded by a well-demarcated and localized apoptosis of the retina outer nuclear layer cells within the laser beam path. Later, death of retinal outer nuclear cells and layer thinning at this site was followed by evagination of the inner nuclear retinal layer. Funneling of the entire inner nuclear and the thinned outer nuclear layers into the choroid lesion center was accompanied by "dragging" of the retinal capillaries. Thus, from days 10 to 14 after krypton laser photocoagulation onward, well-formed blood capillaries (of retinal origin) were observed within the lesion. Only a few of the vW-positive capillary endothelial cells stained also for PCNA p36. In the choroid, dilatation of the vascular bed occurred at the vicinity of the

  13. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.

    Science.gov (United States)

    Lüdemann, Lutz; Nafz, Benno; Elsner, Franz; Grosse-Siestrup, Christian; Meissler, Michael; Kaufels, Nicola; Rehbein, Hagen; Persson, Pontus B; Michaely, Henrik J; Lengsfeld, Philipp; Voth, Matthias; Gutberlet, Matthias

    2009-03-01

    To evaluate for the first time in an animal model the possibility of absolute regional quantification of renal medullary and cortical perfusion by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a blood pool contrast agent. A total of 18 adult female pigs (age, 16-22 weeks; body weight, 45-65 kg; no dietary restrictions) were investigated by DCE-MRI. Absolute renal blood flow (RBF) measured by an ultrasound transit time flow probe around the renal vein was used as the standard of reference. An inflatable stainless cuff placed around the renal artery near its origin from the abdominal aorta was used to reduce RBF to 60%, 40%, and 20% of the baseline flow. The last measurement was performed with the cuff fully reopened. Absolute RBF values during these 4 perfusion states were compared with the results of DCE-MRI performed on a 1.5-T scanner with an 8-channel phased-array surface coil. All scans were acquired in breath-hold technique in the coronal plane using a field of view of 460 mm.Each dynamic scan commenced with a set of five 3D T1-weighted gradient echo sequences with different flip angles (alpha = 2 degrees, 5 degrees, 10 degrees, 20 degrees, 30 degrees): TE, 0.88 milliseconds; TR, 2.65 milliseconds; slice thickness, 8.8 mm for 4 slices; acquisition matrix, 128 x 128; and acquisitions, 4. These data served to calculate 3D intrinsic longitudinal relaxation rate maps (R10) and magnetization (M0). Immediately after these images, the dynamic 3D T1-weighted gradient echo images were acquired with the same parameters and a constant alpha = 30 degrees, half Fourier, 1 acquisition, 64 frames, a time interval of 1.65 seconds between each frame, and a total duration of 105.6. Three milliliters of an albumin-binding blood pool contrast agent (0.25 mmol/mL gadofosveset trisodium, Vasovist, Bayer Schering Pharma AG, Berlin, Germany) was injected at a rate of 3 mL/s. Perfusion was calculated using the arterial input function from the aorta, which was

  14. Krypton retention on solid adsorbents

    International Nuclear Information System (INIS)

    Monson, P.R. Jr.

    1982-01-01

    An experimental laboratory program was conducted to develop economical solid adsorbents for the retention of krypton from a dissolver off-gas stream. The study indicates that a solid adsorbent system is feasible and competitive with other developing systems which utilize fluorocarbon absorption nd cryogenic distillation. This technology may have potential applications not only in nuclear fuel reprocessing plants, but also in nuclear reactors and in environmental monitoring. Of the 13 prospective adsorbents evaluated with respect to adsorption capacity and cost, the commercially available hydrogen mordenite was the most cost-effective material at subambient temperatures (-40 0 to -80 0 C). Silver mordenite has a higher capacity for krypton retention, but is 50 times more expensive than hydrogen mordenite

  15. Krypton for computed tomography lung ventilation imaging: preliminary animal data.

    Science.gov (United States)

    Mahnken, Andreas H; Jost, Gregor; Pietsch, Hubertus

    2015-05-01

    The objective of this study was to assess the feasibility and safety of krypton ventilation imaging with intraindividual comparison to xenon ventilation computed tomography (CT). In a first step, attenuation of different concentrations of xenon and krypton was analyzed in a phantom setting. Thereafter, 7 male New Zealand white rabbits (4.4-6.0 kg) were included in an animal study. After orotracheal intubation, an unenhanced CT scan was obtained in end-inspiratory breath-hold. Thereafter, xenon- (30%) and krypton-enhanced (70%) ventilation CT was performed in random order. After a 2-minute wash-in of gas A, CT imaging was performed. After a 45-minute wash-out period and another 2-minute wash-in of gas B, another CT scan was performed using the same scan protocol. Heart rate and oxygen saturation were measured. Unenhanced and krypton or xenon data were registered and subtracted using a nonrigid image registration tool. Enhancement was quantified and statistically analyzed. One animal had to be excluded from data analysis owing to problems during intubation. The CT scans in the remaining 6 animals were completed without complications. There were no relevant differences in oxygen saturation or heart rate between the scans. Xenon resulted in a mean increase of enhancement of 35.3 ± 5.5 HU, whereas krypton achieved a mean increase of 21.9 ± 1.8 HU in enhancement (P = 0.0055). The use of krypton for lung ventilation imaging appears to be feasible and safe. Despite the use of a markedly higher concentration of krypton, enhancement is significantly worse when compared with xenon CT ventilation imaging, but sufficiently high for CT ventilation imaging studies.

  16. Evaluation of activated charcoal for dynamic adsorption of krypton and xenon

    International Nuclear Information System (INIS)

    Khan, A.A.; Deshingkar, D.S.; Ramarathinam, K.; Kishore, A.G.

    1975-01-01

    From the standpoint of radiation safety, the release of radioactive krypton and xenon from power reactors should be kept as low as practicable. The decay of shortlived isotopes of krypton and xenon by adsorptive delay on activated charcoal has shown promising results for this purpose. The delay provided by activated charcoal is proportional to the dynamic adsorption coefficients of these gases which are characteristic of the adsorbent. These coefficients were determined for krypton and xenon on indigenous gas-adsorbing activated charcoal at different moisture contents of carrier air stream and activated charcoal, concentrations of krypton around ambient temperatures, to find its suitability for designing adsorber columns. (author)

  17. Gated cardiac blood pool studies in arrhythmias

    International Nuclear Information System (INIS)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed [fr

  18. Gated cardiac blood pool studies in arrhythmias

    Energy Technology Data Exchange (ETDEWEB)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed.

  19. Selective adsorption-desorption method for the enrichment of krypton

    International Nuclear Information System (INIS)

    Yuasa, Y.; Ohta, M.; Watanabe, A.; Tani, A.; Takashima, N.

    1975-01-01

    Selective adsorption-desorption method has been developed as an effective means of enriching krypton and xenon gases. A seriesof laboratory-scale tests were performed to provide some basic data of the method when applied to off-gas streams of nuclear power plants. For the first step of the enrichment process of the experiments, krypton was adsorbed on solid adsorbents from dilute mixtures with air at temperatures ranging from -50 0 C to -170 0 C. After the complete breakthrough was obtained, the adsorption bed was evacuated at low temperature by a vacuum pump. By combining these two steps krypton was highly enriched on the adsorbents, and the enrichment factor for krypton was calculated as the product of individual enrichment factors of each step. Two types of adsorbents, coconut charcoal and molecular sieves 5A, were used. Experimental results showed that the present method gave the greater enrichment factor than the conventional method which used selective adsorption step only. (U.S.)

  20. Krypton gas cylinders as a source of radiation.

    Science.gov (United States)

    Fischer, Helmut W; Bielefeld, Tom; Hettwig, Bernd

    2010-07-01

    A standard 40 foot shipping container with a cargo of pressurized krypton gas in 159 steel cylinders, which had triggered a radiation alarm, was investigated to address radiation safety and illicit nuclear trafficking concerns. The investigation included contamination and dose rate measurements as well as in situ high resolution gamma spectroscopy. The dose rate measurements gave a maximum value of 0.07 microSv h(-1) above background (0.08 to 0.11 microSv h(-1)) on the cylinder surface and no detectable increase above background at distances of 1 m and higher. Contamination monitor readings showed a similar relative increase (plus 8 cpm) above background (about 12 cpm) to the dose rate readings. Quantitative gamma spectroscopy revealed a contamination of the gas with 85Kr at a level of 3.5 x 10(5) Bq kg(-1). This value was found to be consistent with analytical and numerical estimates based on current data for atmospheric 85Kr, which is captured from ambient air together with stable krypton during the production process. This incident demonstrates an apparent lack of radiation-related knowledge by those who handle krypton gas, as well as by border control personnel and emergency responders. We therefore propose to improve labeling and documentation standards for such shipments. This effort may be facilitated by introducing the new category of "technically enhanced artificial radioactive material," or "TEARM" (similar to the existing "naturally occurring radioactive material" or "NORM" and "technically enhanced naturally occurring radioactive material" or "TENORM" categories).

  1. Thermal stability of the krypton Hall effect thruster

    Directory of Open Access Journals (Sweden)

    Szelecka Agnieszka

    2017-03-01

    Full Text Available The Krypton Large IMpulse Thruster (KLIMT ESA/PECS project, which has been implemented in the Institute of Plasma Physics and Laser Microfusion (IPPLM and now is approaching its final phase, was aimed at incremental development of a ~500 W class Hall effect thruster (HET. Xenon, predominantly used as a propellant in the state-of-the-art HETs, is extremely expensive. Krypton has been considered as a cheaper alternative since more than fifteen years; however, to the best knowledge of the authors, there has not been a HET model especially designed for this noble gas. To address this issue, KLIMT has been geared towards operation primarily with krypton. During the project, three subsequent prototype versions of the thruster were designed, manufactured and tested, aimed at gradual improvement of each next exemplar. In the current paper, the heat loads in new engine have been discussed. It has been shown that thermal equilibrium of the thruster is gained within the safety limits of the materials used. Extensive testing with both gases was performed to compare KLIMT’s thermal behaviour when supplied with krypton and xenon propellants.

  2. Spiral density waves in M81. I. Stellar spiral density waves

    International Nuclear Information System (INIS)

    Feng, Chien-Chang; Lin, Lien-Hsuan; Wang, Hsiang-Hsu; Taam, Ronald E.

    2014-01-01

    Aside from the grand-design stellar spirals appearing in the disk of M81, a pair of stellar spiral arms situated well inside the bright bulge of M81 has been recently discovered by Kendall et al. The seemingly unrelated pairs of spirals pose a challenge to the theory of spiral density waves. To address this problem, we have constructed a three-component model for M81, including the contributions from a stellar disk, a bulge, and a dark matter halo subject to observational constraints. Given this basic state for M81, a modal approach is applied to search for the discrete unstable spiral modes that may provide an understanding for the existence of both spiral arms. It is found that the apparently separated inner and outer spirals can be interpreted as a single trailing spiral mode. In particular, these spirals share the same pattern speed 25.5 km s –1 kpc –1 with a corotation radius of 9.03 kpc. In addition to the good agreement between the calculated and the observed spiral pattern, the variation of the spiral amplitude can also be naturally reproduced.

  3. A comparison of the economics of xenon 127, xenon 133 and krypton 81m for routine ventilation imaging of the lungs

    International Nuclear Information System (INIS)

    Nimmo, M.J.; Merrick, M.V.; Millar, A.M.

    1985-01-01

    The authors have compared the cost of providing routine lung ventilation scintigraphy using 127 Xe with other radioactive gases in 100 patients. The physical properties of 127 Xe permit a logical imaging sequence where a ventilation study is only carried out if indicated by perfusion scintigraphy which is performed first. With 133 Xe, all patients must be ventilated prospectively, or a preselection carried out based on radiographic appearances at the time of imaging. This results in a greater number of ventilation studies than with 127 Xe. Despite the greater cost per study of 127 Xe, the overall cost of providing a routine diagnostic service with this gas is no more than that of using 133 Xe in selected patients. The cost of ventilating all patients prospectively with 133 Xe is considerably greater than using 127 Xe only when indicated by abnormal perfusion images. If ventilation imaging is to be available at all times, either isotope of xenon costs very much less than 81 Krsup(m). It is concluded that 127 Xe is the radiopharmaceutical of choice for routine lung ventilation scintigraphy. (author)

  4. Using zeolites for fixation and long-term storage of krypton

    International Nuclear Information System (INIS)

    Pirogova, G.N.; Voronin, Yu.V.; Pribylov, A.A.; Serpinskii, V.V.; Mirskii, Ya.V.; Almazova, B.B.; Golitsina, V.V.

    1993-01-01

    It is known that large quantities of 85 Kr are liberated during the operation of nuclear power plants and, in particular, during the processing of nuclear fuel. At the present time, there are several methods of its fixation (accumulation), viz., storage in high-pressure gas balloons, adsorption, plasma-aided implantation into metals, introduction into clathrate compounds, and obtaining kryptonates. Encapsulation in zeolites is one of the most promising methods. The merits of this method include safety during storage, a favorable volume-to-mass ratio, the possibility of separating krypton from a mixture of different gases, and purity of the encapsulated gas. The encapsulation technique has been developed quite recently. Several recent reports established the possibility of encapsulating krypton in the 3A-type zeolites. However, most of the investigators observed leakage during the storage of the zeolite-gas system and complete liberation of krypton from the zeolite during prolonged storage. This paper deals with a study of the encapsulation process of krypton in the zeolites obtained by cation exchange from NaA. The experimental specimens were characterized by the degree of exchange of sodium into potassium and cesium. It is known that the introduction of cesium into the structure (body) of a zeolite reduces the size of the window of entrance. All the synthesized specimens were used in their granulated form. The aim of this study was to develop zeolite specimens for carrying out long-term storage of krypton

  5. Contribution to the study of the structure of silver krypton solid solutions; Contribution a l'etude de la structure des solutions solides argent-krypton

    Energy Technology Data Exchange (ETDEWEB)

    Levy, V; Tullairet, J; Delaplace, J; Antolin-Baudier, J; Adda, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The silver-krypton solid solutions formed by electrical discharge have been studied by X-rays, electrical resistivity and electronic transmission microscopy. The crystalline parameter and residual resistivity measurements have shown that the krypton atom behaves very differently to those of other elements of the periodic classification when dissolved in silver. The recovery of the crystalline parameter and of the electrical resistivity has been studied as a function of temperature. (authors) [French] Les solutions solides argent, krypton, realisees par decharges electrique ont ete etudiees par Rayons X, resistivite electrique et microscopie electronique en transmission. Les mesures de parametre cristallin et de resistivite residuelle ont montre que le comportement de l'atome de krypton est tres different de celui des autres elements de la classification periodique en solution dans l'argent. La restauration du parametre cristallin et de la resistivite electrique en fonction de la temperature a ete etudiee. (auteurs)

  6. Empirical evaluation of the radiative cooling coefficient for krypton gas in the FTU plasma

    International Nuclear Information System (INIS)

    Fournier, K.B.; Pacella, D.; Mazzitelli, G.; Stutman, D.; Soukanovskii, V.; Goldstein, W.H.

    1997-01-01

    For future fusion reactors, a careful balance must be achieved between the cooling of the outer plasma via impurity radiation and the deleterious effects of inevitable core penetration by impurity ions. We have injected krypton gas into the Frascati Tokamak Upgrade (FTU) plasma. The measured visible bremsstrahlung and bolometric signals from krypton have been inverted and the resulting radial impurity density profile and power loss profile for krypton gas are extracted. Using the measured electron density and temperature profiles, the radiative cooling coefficient for krypton is derived. The level of intrinsic impurities (Mo, Cr, Mn and Fe) in the plasma during the krypton puffing is monitored with a VUV SPRED spectrometer. Models for krypton emissivity from the literature are compared to our measured results. 7 figs

  7. Environmental behaviour and dosimetry of Krypton-85

    International Nuclear Information System (INIS)

    Patek, P.

    1980-12-01

    Although 85 Kr has only small influence on the total radiation burden to man, monitoring and safety considerations have to be done, especially regarding the operation of fuel reprocessing plants. The natural, military and civilian sources of 85 Kr are discussed and a survey is given on the possibilities of Krypton removal from off-gas streams. Regarding the environmental behaviour of the released Krypton-amounts it was shown, that only the atmospheric dispersion is of influence to the succeeding irradiation of the population. Krypton is transferred to man only by inhalation and remains with different halflives in the human body. The highest absorbed dose is caused by beta-rays to the skin and in the airways of the lungs. While the highest dose equivalent rates to the most exposed individuals are reached by local sources from fuel reprocessing plants, the highest collective effective dose equivalent commitment is reached for global dispersed 85 Kr. (author)

  8. Sensitivity of nested-PCR for plasmodium detection in pooled whole blood samples and its usefulness to blood donor screening in endemic areas.

    Science.gov (United States)

    de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen

    2014-04-01

    Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Internal plasma potential measurements of a Hall thruster using xenon and krypton propellant

    International Nuclear Information System (INIS)

    Linnell, Jesse A.; Gallimore, Alec D.

    2006-01-01

    For krypton to become a realistic option for Hall thruster operation, it is necessary to understand the performance gap between xenon and krypton and what can be done to reduce it. A floating emissive probe is used with the Plasmadynamics and Electric Propulsion Laboratory's High-speed Axial Reciprocating Probe system to map the internal plasma potential structure of the NASA-173Mv1 Hall thruster [R. R. Hofer, R. S. Jankovsky, and A. D. Gallimore, J. Propulsion Power 22, 721 (2006); and ibid.22, 732 (2006)] using xenon and krypton propellant. Measurements are taken for both propellants at discharge voltages of 500 and 600 V. Electron temperatures and electric fields are also reported. The acceleration zone and equipotential lines are found to be strongly linked to the magnetic-field lines. The electrostatic plasma lens of the NASA-173Mv1 Hall thruster strongly focuses the xenon ions toward the center of the discharge channel, whereas the krypton ions are defocused. Krypton is also found to have a longer acceleration zone than the xenon cases. These results explain the large beam divergence observed with krypton operation. Krypton and xenon have similar maximum electron temperatures and similar lengths of the high electron temperature zone, although the high electron temperature zone is located farther downstream in the krypton case

  10. [99mTc]teboroxime and [99mTc]Cl(DMG)3B2MP: binding characteristics and metabolism of two [99mTc]BATOs in blood and tissues

    International Nuclear Information System (INIS)

    Rosenspire, K.C.; Rumsey, W.L.; Jurisson, S.; Hirth, W.; Narra, R.K.

    1993-01-01

    Studies were performed in vitro and in vivo to evaluate the binding properties and metabolism of [ 99m Tc]Cl(CDO) 3 BMe (Teboroxime) and [ 99m Tc]Cl(DMG) 3 B2MP in blood and target issues of rats. Both radiopharmaceuticals displayed rapid binding (within 1-3 min) with high affinity to plasma proteins and blood cells. The amounts of radioactivity associated with blood components became progressively greater with time of exposure to either compound. There was a higher proportion of the radiopharmaceuticals associated with blood components during in vivo conditions, likely due, at least in part, to clearance of the free fraction from the plasma pool. Exposure of both compounds to blood results in axial ligand exchange of the chloro atom to a hydroxyl. The results suggest that it is the free species that is extracted primarily by tissues. (Author)

  11. [99mTc]teboroxime and [99mTc]Cl(DMG)3B2MP: binding characteristics and metabolism of two [99mTc]BATOs in blood and tissues

    International Nuclear Information System (INIS)

    Rosenspire, K.C.; Rumsey, W.L.; Jurisson, S.; Hirth, W.; Narra, R.K.

    1993-01-01

    Studies were performed in vitro and in vivo to evaluate the binding properties and metabolism of [ 99m Tc]Cl(CDO) 3 BMe (Teboroxime) and [ 99m Tc]Cl(DMG) 3 B2MP in blood and target tissues of rats. Both radiopharmaceuticals displayed rapid binding (within 1-3 min) with high affinity to plasma proteins and blood cells. The amounts of radioactivity associated with blood components became progressively greater with time of exposure to either compound. There was a higher proportion of the radiopharmaceuticals associated with blood components during in vivo conditions, likely due, at least in part, to clearance of the free fraction from the plasma pool. Exposure of both compounds to blood results in axial ligand exchange of the chloro atom to a hydroxyl. The results suggest that it is the free species that is extracted primarily by tissues. (author)

  12. Detection of soft tissue pathology on the blood pool phase of bone scans

    International Nuclear Information System (INIS)

    Raimondo, A.J.; Turner, H.A.; Kitchener, M.I.

    1999-01-01

    Full text: It is important to optimize information obtained from isotope bone scanning in musculoskeletal imaging. Although important at all times, it is especially imperative in the current climate of health services rationalization, capping of imaging expenditure and the promotion of newer modalities that are increasingly versatile and sensitive for imaging the musculoskeletal system. Careful attention must be paid to the blood flow and blood pool images, to visualize soft tissue as well as bony pathology. A series of cases and images will be presented that demonstrated blood pool pathology that was not appreciated on delayed imaging, or where reliance only on the delayed images would have led to an incorrect diagnosis. These include the detection of tendonitis, tenosynovitis, bursitis, muscle tears and soft tissue neoplasms, including neuromas. In cases where the bone scan cannot provide a definitive diagnosis, it will at least direct the referring clinician to the most appropriate confirmatory diagnostic imaging modality, thus reinforcing the value that isotope imaging provides in musculoskeletal medicine

  13. Study on immobilization technology of krypton gas by ion-implantation and sputtering process

    International Nuclear Information System (INIS)

    Hayashi, S.; Kamiya, S.; Ikeda, S.; Nakanishi, Y.

    1997-01-01

    At the Waste Technology Development Division of PNC''s Tokai Works, we have been carrying out the development of the recovering and storing technology of radioactive krypton to reduce the radioactive gaseous effluent released to the environment arising from reprocessing of nuclear spent fuels. As a part of this technical development, the method of storing radioactive krypton is an encapsulation in a metal matrix which appears to offer the most secure immobilization of krypton. From the result of the ion-implantation test used non-radioactive krypton and the evaluation of electrical characteristics, we have selected the metallic materials, they are Nickel and Yttrium, and designed the vessel and the apparatus which continuously immobilized the krypton into metal matrix. This article described the following experiment result. (1) The long-term immobilization technology was established with respect to handling a equipment and plasma controlling. (2) Stability of the krypton immobilized alloy was considered satisfactory because the release was tolerably small. (author)

  14. Fourier plane modeling of the jet in the galaxy M81

    Science.gov (United States)

    Ramessur, Arvind; Bietenholz, Michael F.; Leeuw, Lerothodi L.; Bartel, Norbert

    2015-03-01

    The nearby spiral galaxy M81 has a low-luminosity Active Galactic Nucleus in its center with a core and a one-sided curved jet, dubbed M81*, that is barely resolved with VLBI. To derive basic parameters such as the length of the jet, its orientation and curvature, the usual method of model-fitting with point sources and elliptical Gaussians may not always be the most appropriate one. We are developing Fourier-plane models for such sources, in particular an asymmetric triangle model to fit the extensive set of VLBI data of M81* in the u-v plane. This method may have an advantage over conventional ones in extracting information close to the resolution limit to provide us with a more comprehensive picture of the structure and evolution of the jet. We report on preliminary results.

  15. Global characteristics of an ATON stationary plasma thruster operating with krypton and xenon

    International Nuclear Information System (INIS)

    Bugrova, A.I.; Lipatov, A.S.; Solomatina, L.V.; Morozov, A.I.

    2002-01-01

    Paper contains the experimental results of operation of the ATON plasma thruster operating with krypton and xenon. It is shown that consumption of a working gas for consumption of a working gas the krypton base thrust is higher in contrast to xenon base one at lower efficiency. In case of krypton use one obtained the efficiency constituting ∼ 60% at specific pulse reaching 3000 s. Jet divergence in case of krypton use is ∼ ± 22 deg in contrast to ∼ ± 11 deg in case of xenon use [ru

  16. A review of ''The potential effects of release of krypton-85''

    International Nuclear Information System (INIS)

    Saunders, C.P.R.

    1993-06-01

    A Report into the potential effects of the release of Krypton-85 from the Thermal Oxide Reprocessing Plant (THORP) at Sellafield, was commissioned by British Nuclear Fuels Ltd. The report dealt with the atmospheric impact of the release of Krypton-85 and considered specifically the areas of atmospheric electricity, ionisation, aerosols and conductivity, in terms of the releases of Krypton-85 from THORP. This present review has three objectives: to consider the atmospheric effects of the proposed discharges from THORP, to comment upon the magnitude of the postulated effects from Krypton-85 discharges compared with those from other sources of radioactivity in the atmosphere, and, to comment on the conclusions drawn by the authors of the report. This review was conducted under the aegis of the United Kingdom Inspectorate of Pollution. (author)

  17. Krypton-85 Monitoring at BfS in Germany and Technical Solutions for Safeguards

    International Nuclear Information System (INIS)

    Schlosser, C.; Klingberg, F.

    2015-01-01

    The radioactive noble gas isotope krypton-85 with a half-life of 10.76 years is produced by nuclear fission. The main source of krypton-85 in the atmosphere are releases from reprocessing plants for nuclear fuel in the Northern Hemisphere. This volatile isotope is not retained in such plants and thus a very good indicator for the processing of irradiated nuclear fuel. This includes reprocessing for military purposes. Additionally, Kr-85 could be used as tracer for the validation of Atmospheric Transport Models. The German Federal Office for Radiation Protection (BfS) operates a noble gas laboratory and a global network which continuously monitors the krypton-85 activity concentrations in ground level air since the 1970s. The atmospheric activity concentration has continuously been increasing since the installation of reprocessing plants for nuclear fuels in the early 1950s until 2003. In the first decades it came mostly from military applications and later from civil reprocessing. Since 2003 the atmospheric krypton-85 background level in the Northern Hemisphere is nearly constant with a value of around 1.5 Bq/m 3 in Central Europe. The baseline is superimposed by spikes as a result from discharges of two European reprocessing plants of nuclear fuel, Sellafield and La Hague. The laboratory of the BfS and the techniques used will be presented. Long time series will be discussed and the use of ATM for source location demonstrated. (author)

  18. Confidence limits for regional cerebral blood flow values obtained with circular positron system, using krypton-77

    International Nuclear Information System (INIS)

    Meyer, E.; Yamamoto, Y.L.; Thompson, C.J.

    1978-01-01

    The 90% confidence limits have been determined for regional cerebral blood flow (rCBF) values obtained in each cm 2 of a cross section of the human head after inhalation of radioactive krypton-77, using the MNI circular positron emission tomography system (Positome). CBF values for small brain tissue elements are calculated by linear regression analysis on the semi-logarithmically transformed clearance curve. A computer program displays CBF values and their estimated error in numeric and gray scale forms. The following typical results have been obtained on a control subject: mean CBF in the entire cross section of the head: 54.6 + - 5 ml/min/100 g tissue, rCBF for small area of frontal gray matter: 75.8 + - 9 ml/min/100 g tissue. Confidence intervals for individual rCBF values varied between + - 13 and + - 55% except for areas pertaining to the ventricular system where particularly poor statistics have been obtained. Knowledge of confidence limits for rCBF values improves their diagnostic significance, particularly with respect to the assessment of reduced rCBF in stroke patients. A nomogram for convenient determination of 90% confidence limits for slope values obtained in linear regression analysis has been designed with the number of fitted points (n) and the correlation coefficient (r) as parameters. (author)

  19. Separation of radioactive krypton from carbon dioxide and oxygen with molecular sieves

    International Nuclear Information System (INIS)

    Forsberg, C.W.

    1977-10-01

    In the reprocessing of HTGR nuclear fuels, the off-gas cleanup system generates a stream containing about 1 percent krypton, 90+ percent CO 2 , and various amounts of O 2 , N 2 , and xenon. The krypton is radioactive and must be separated from the CO 2 before it is bottled or zeolite-encapsulated for final disposal. A series of theoretical and experimental investigations to find the best method for separating CO 2 and krypton under the required conditions showed that 5A molecular sieves near O 0 C and 1.01 x 10 5 Pa (1 atm) provided the most effective separation. Molecular sieves are powerful solid adsorbents for CO 2 but weak adsorbents for krypton. For a typical expected CO 2 -O 2 -krytpon gas mixture, a molecular sieve bed adsorbs the CO 2 , allows the O 2 to pass freely through the bed, and concentrates the krypton before it exits the bed. The process selected and investigated is called frontal analysis gas chromatography

  20. Krypton calibration of time projection chambers of the NA61/SHINE experiment

    CERN Document Server

    Naskret, Michal

    The NA61/SHINE experiment at CERN is searching for the critical point in phase transition between quark-gluon plasma and hadronic matter. To do so we use the most precise apparatus - Time Projection Chamber. Its main task is to find trajectories of particles created in a relativistic collision. In order to improve efficiency of TPCs, we introduce calibration using radioactive krypton gas. Simulation of events in a TPC cham- ber through a decay of excited krypton atoms gives us a spectrum, which is later fitted to the model spectrum of krypton from a Monte-Carlo simulation. The data obtained in such a way serves us to determine malfunctioning electronics in TPCs. Thanks to the krypton calibration we can create a map of pad by pad gains. In this thesis I will de- scribe in detail the NA61 experimental setup, krypton calibration procedure, calibration algorithm and results for recent calibration runs

  1. Alterations of the blood pool in the femoral head before and after renal transplantation

    International Nuclear Information System (INIS)

    Hamaguchi, Hiroyuki; Fujioka, Mikihiro; Inoue, Shigehiro; Shibatani, Masahiko; Kubo, Toshikazu; Kubota, Takao; Ushijima, Yo; Nishimura, Tsunehiko

    2003-01-01

    The pathogenesis of idiopathic osteonecrosis of the femoral head (ION) is thought to be an ischemic event. The purpose of this study is to investigate alterations of the blood pool in the femoral head before and after renal transplantation. After renal transplantation, all patients received the same immunosuppressive therapy: corticosteroids, cyclosporin-A, and azathioprine. We performed 3-phase bone scintigraphy on 16 renal allograft recipients within 1 week before renal transplantation, and between week 4 and 9 after renal transplantation. Regions of interest (ROI) were assigned bilaterally in the femoral head, diaphysis, and soft tissue. The head-to-diaphysis ratios (HD ratios) were then calculated. Idiopathic osteonecrosis of the femoral head occurred in 2 femoral heads of 1 patient. The HD ratio before renal transplantation (mean HD±SD, 1.52±0.30) and the HD ratio after renal transplantation (1.28±0.30) were significantly different (P=0.000024). The HD ratios before and after renal transplantation were significantly different, indicating that the administration of steroids diminished the blood pool in the femoral head. A low HD ratio before renal transplantation revealed a poor blood pool in the femoral head, which may be a risk factor for ION. (author)

  2. Self-compression of femtosecond deep-ultraviolet pulses by filamentation in krypton.

    Science.gov (United States)

    Adachi, Shunsuke; Suzuki, Toshinori

    2017-05-15

    We demonstrate self-compression of deep-ultraviolet (DUV) pulses by filamentation in krypton. In contrast to self-compression in the near-infrared, that in the DUV is associated with a red-shifted sub-pulse appearing in the pulse temporal profile. The achieved pulse width of 15 fs is the shortest among demonstrated sub-mJ deep-ultraviolet pulses.

  3. The Liquid Krypton Calorimeter Cryogenics for the NA48 Experiment

    CERN Document Server

    Bremer, J; Dauvergne, J P; Gonidec, A; Kesseler, G; Kubischta, Werner; Linser, G; Schinzel, D; Taureg, Hans; Wertelaers, Piet

    1998-01-01

    The NA48 cryogenic system has to provide stable thermal conditions (120 K) in a 9000 liter liquid krypton calorimeter, and has to ensure safe and loss free storage of the liquid during idle periods. Direct cooling of the krypton by nitrogen is used in emergency cases, while an intermediate cooler, containing saturated liquid argon at around 10 bar (117 K) is used under normal operation conditions when high thermal stability is needed. The krypton pressure is, during data taking, regulated to a value of (1.05 ± 0.01) bar for a period of about 8 months of continuous operation of the calorimeter.

  4. Determination of regional esophageal transit in children by means of krypton-8 1m

    International Nuclear Information System (INIS)

    Piepsz, A.; Ham, H.R.; Georges, B.; Delaet, M.H.; Cadranel, S.

    1984-01-01

    Radionuclide methods using Tc-99m have been developed in the last few years for the assessment of the esophageal transit. The method is physiologic, easy to perform and giving thus interesting informations concerning the severity of the disease as well as the effect of the applied treatment. In children, however, one is limited by radiation protection considerations, and the results are often of poor quality due to the low count rate. Furthermore, the risk of external contamination and the impossibility of repeating the test constitute significant disadvantages, particularly in young children. These problems are completely avoided by using Krypton-8lm diluted in a glucose solution. For each swallowing about 8 mCi of Kr-8 lm are administered. Sixty one-second frames are recorded and several parameters of regional transit can be extracted in a few minutes, using time activity curves and parametric images. The test is very sensitive in detecting minor regional transit alterations. The reproducibility of the test is good and phenomenons like intercurrent gastro-esophageal reflux or asynergic peristaltic waves can easily be detected. The test has been applied to 52 children, aged 1 week to 19 years, and provided helpful information concerning the localization and the importance of transit abnormalities in caustic and peptic esophagitis, postoperative cases (atresia or antireflux plasty) and in patients with neuromuscular disorders

  5. Climate aspects of radioactive trace gases, especially krypton-85

    International Nuclear Information System (INIS)

    Kollert, R.; Butzin, M.

    1990-01-01

    The amount of krypton 85 currently present in the atmosphere is 3.300 Peta Bq. This atmospheric krypton contamination stems from atom bomb tests of the past and from nuclear power plants as well as spent fuel reprocessing plants. The paper investigates the air-electric and air-chemical impact of Kr-85 on the atmosphere and makes a forecast of the future Kr-85 contamination. (DG) [de

  6. Krypton-85 enrichment by adsorption-desorption process

    International Nuclear Information System (INIS)

    Khan, A.A.; Deshingkar, D.S.; Ramarathinam, K.

    1975-01-01

    The use of activated charcoal columns in conjunction with cryogenic distillation system for concentration of krypton-85 in fuel reprocessing process off-gas stream is reported. Dynamic adsorption of krypton on activated charcoals and its subsequent desorption by applying vacuum were studied. The possible reduction in the quantity of carrier gas to be liquified in the cryogenic system by utilising this process has been discussed on the basis of results of laboratory evaluations. The possibility of elimination of air and oxygen to avoid explosion hazards associated with radiolytic formation and concentration of ozone has also been considered. (author)

  7. 10 CFR 30.19 - Self-luminous products containing tritium, krypton-85, or promethium-147.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Self-luminous products containing tritium, krypton-85, or..., krypton-85, or promethium-147. (a) Except for persons who manufacture, process, produce, or initially transfer for sale or distribution self-luminous products containing tritium, krypton-85, or promethium-147...

  8. Experimental and clinical analyses of optimum Fourier filtering in ECG-gated blood pool scintigraphy

    International Nuclear Information System (INIS)

    Shimabukuro, Kunisada

    1988-01-01

    A phantom study was undertaken to determine the optimum order harmonics in Fourier analysis for volume curves obtained by ECG-gated blood pool scintigraphy. The volume curve obtained by Tc-99m scintigraphy was computed by the 1st through 10th order harmonics of Fourier transform. The shape of each volume curve fitted by Fourier transform was compared with the shape of the generated ideal curve. Curves fitted with the 3rd or more order harmonics were approximate to the ideal curve in shape during the systolic phase. The 6th to 10th order harmonics were suitable for the early diastole phase. As determined by peak ejection rate and peak filling rate (PFR), the 6th order harmonics was superior to the 3rd order harmonics in evaluating early diastolic abnormalities. In the clinical settings, there was no difference between the 3rd and 6th order harmonics in evaluating systolic abnormalities; however, the 6th order harmonics was more sensitive than the 3rd order harmonics in evaluating early diastolic abnormalities. The 6th order harmonics significantly reflected PFR in the group of hypertrophic cardiomyopathy (n=10) and time to PFR in the groups of old myocardial infarction (n=10) and angina pectoris (n=10). In conclusion, the 6th to 9th order harmonics of Fourier analysis may be useful in analyzing both systolic and early diastolic phases inf left ventricular volume curves obtained from ECG-gated cardiac blood pool scintigraphy. (Namekawa, K)

  9. Krypton based adsorption type cryogenic refrigerator

    Science.gov (United States)

    Jones, Jack A. (Inventor); Schember, Helene R. (Inventor)

    1989-01-01

    Krypton and a monolithic porous carbon such as Saran carbon are used respectively as the sorbate and sorbent of an adsorption type refrigerator to improve refrigeration efficiency and operational longevity.

  10. Hyperpolarized 3He MRI and 81mKr SPECT in chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Stavngaard, Trine; Søgaard, Lise; Mortensen, J

    2005-01-01

    visual defect score (r=0.80, pemphysema (pulmonary function test and HRCT). The defect scores were largest on 81mKr SPECT (the score on HP 3He MRI...... was to compare ventilation imaging methods in 26 patients with chronic obstructive pulmonary disease (COPD) and nine lung healthy volunteers. METHODS: HP 3He MRI, 81mKr single-photon emission computed tomography (SPECT), high-resolution computed tomography (HRCT) and pulmonary function tests were performed....... The three scans were scored visually as percentage of non-ventilated/diseased lung, and a computer-based objective measure of the ventilated volume in HP 3He MRI and 81mKr SPECT and an emphysema index in HRCT were calculated. RESULTS: We found a good correlation between HP 3He MRI and 81mKr SPECT for both...

  11. Nanoparticle encapsulation in red blood cells enables blood-pool magnetic particle imaging hours after injection

    International Nuclear Information System (INIS)

    Rahmer, J; Gleich, B; Borgert, J; Antonelli, A; Sfara, C; Magnani, M; Tiemann, B; Weizenecker, J

    2013-01-01

    Magnetic particle imaging (MPI) is a new medical imaging approach that is based on the nonlinear magnetization response of super-paramagnetic iron oxide nanoparticles (SPIOs) injected into the blood stream. To date, real-time MPI of the bolus passage of an approved MRI SPIO contrast agent injected into the tail vein of living mice has been demonstrated. However, nanoparticles are rapidly removed from the blood stream by the mononuclear phagocyte system. Therefore, imaging applications for long-term monitoring require the repeated administration of bolus injections, which complicates quantitative comparisons due to the temporal variations in concentration. Encapsulation of SPIOs into red blood cells (RBCs) has been suggested to increase the blood circulation time of nanoparticles. This work presents first evidence that SPIO-loaded RBCs can be imaged in the blood pool of mice several hours after injection using MPI. This finding is supported by magnetic particle spectroscopy performed to quantify the iron concentration in blood samples extracted from the mice 3 and 24 h after injection of SPIO-loaded RBCs. Based on these results, new MPI applications can be envisioned, such as permanent 3D real-time visualization of the vessel tree during interventional procedures, bleeding monitoring after stroke, or long-term monitoring and treatment control of cardiovascular diseases. (paper)

  12. Discovery of Five Probable Novae in M81

    Science.gov (United States)

    Hornoch, K.; Errmann, R.; Sowicka, P.; Humphries, N.; Vaduvescu, O.

    2015-10-01

    We report the discovery of five probable novae in M81 on a co-added 2000-s narrow-band H-alpha CCD image taken with the 2.5-m Isaac Newton Telescope (INT) + WFC at La Palma under ~1.5" seeing on 2015 Oct. 14.198 UT. The new objects are well visible on the co-added image (see the finding charts linked below), but are not present on numerous narrow-band H-alpha archival images from the INT down to limiting magnitude as faint as H-alpha = 22.3.

  13. Abdominal blood pool scintigraphy in the management of acute or intermittent gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Kalff, V.; Kelly, M.J.; Dudley, F.; Metz, G.

    1983-01-01

    Gastrointestinal blood pool scintigraphy, using a modified in-vivo blood cell labelling technique with technetium-99, is a new, easily performed, non-invasive procedure. It is valuable in screening patients with acute or intermittent gastrointestinal blood loss in whom duodenoscopic and sigmoidoscopic findings are unhelpful. This paper reviews the value of this scintigraphic technique over the first eight months of its use in a major teaching hospital, and compares the results with other published data. If used and interpreted appropriately, scintigraphy is sensitive in detecting and localizing the bleeding site, and is very helpful in indicating the optimal timing of emergency contrast angiography

  14. Kratom alkaloids and O-desmethyltramadol in urine of a "Krypton" herbal mixture consumer.

    Science.gov (United States)

    Arndt, Torsten; Claussen, Ulrich; Güssregen, Brunhilde; Schröfel, Stefanie; Stürzer, Birgit; Werle, Annika; Wolf, Gerald

    2011-05-20

    A drug and alcohol withdrawal rehabilitation centre requested an analysis for "Krypton" in urine of a former opiate-addictive woman. She showed an altered clinical picture and behaviour with miosis, itchiness, agitation, and moderate euphoria after 3 months of until than successful treatment. Literature search revealed that "Krypton" is said to contain "Kratom" (leaves of Mitragyna speciosa), but could also contain O-desmethyltramadol (European Monitoring Centre for Drugs and Drug Addiction thematic paper "Spice"). Immunological drug screenings were done with test strips (nal von minden, Regensburg, Germany) and with cloned enzyme donor immunoassay (Microgenics, Passau, Germany). "Kratom" alkaloids and tramadol (metabolites) were analyzed by LC-MS/MS (ThermoFisher Scientific Quantum Ultra Triple Quadrupole mass spectrometer). Immunoassays were negative for amphetamines, barbiturates, benzodiazepines, benzoylecgonine, buprenorphine, ethylglucuronide, methadone (metabolite), opiates, oxycodone, and THC-COOH, and test strips were negative for tramadol and its metabolites (cut-off 10 mg/L for O-desmethyltramadol). LC-MS/MS detected the "Kratom" alkaloids mitragynine, speciociliatine, speciogynine, mitraciliatine, and paynantheine and approximately 9mg/L O-desmethyltramadol, but no tramadol and N-desmethyltramadol. The detection of M. speciosa alkaloids is a proof of "Kratom" abuse. Confronted with the analysis data, the patient admitted to have consumed 3-4 infusions of "Krypton". The origin of the O-desmethyltramadol is unclear. Tramadol abuse is unlikely since tramadol and N-desmethyltramadol (physiologically occurring in urine after tramadol intake) were not detectable. Consumption of a "Krypton" product spiked with O-desmethyltramadol could explain our findings and the patient's clinical picture. This would be in agreement with a most recent report about spiking apparently natural herbal mixtures with the synthetic opioid O-desmethyltramadol. Analysis of "Kratom

  15. THE RETENTION OF KRYPTON IN POLYCRYSTALLINE SILICON DURING HIGH-TEMPERATURE ANNEALING

    NARCIS (Netherlands)

    GREUTER, MJW; NIESEN, L; VANVEEN, A; EVANS, JH

    1994-01-01

    In a study into the annealing behaviour of silicon containing a few atomic per cent of krypton, it was found that, even at 0.87 of the silicon melting temperature, approximately 90% of the original krypton was still present. This result is compared with analogous work on metals where copious inert

  16. Quenching of the resonance 5s({sup 3}P{sub 1}) state of krypton atoms in collisions with krypton and helium atoms

    Energy Technology Data Exchange (ETDEWEB)

    Zayarnyi, D A; L' dov, A Yu; Kholin, I V [P N Lebedev Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation)

    2014-11-30

    The processes of collision quenching of the resonance 5s[3/2]{sub 1}{sup o}({sup 3}P{sub 1}) state of the krypton atom are studied by the absorption probe method in electron-beam-excited high-pressure He – Kr mixtures with a low content of krypton. The rate constants of plasmochemical reactions Kr* + Kr + He → Kr*{sub 2} + He [(4.21 ± 0.42) × 10{sup -33} cm{sup 6} s{sup -1}], Kr* + 2He → HeKr* + He [(4.5 ± 1.2) × 10{sup -36} cm{sup 6} s{sup -1}] and Kr* + He → products + He [(2.21 ± 0.22) × 10{sup -15} cm{sup 3} s{sup -1}] are measured for the first time. The rate constants of similar reactions are refined for krypton in the metastable 5s[3/2]{sub 2}{sup o} ({sup 3}P{sub 2}) state. (laser applications and other topics in quantum electronics)

  17. Automatic localization of the left ventricular blood pool centroid in short axis cardiac cine MR images.

    Science.gov (United States)

    Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; Abdul Aziz, Yang Faridah; Chee, Kok Han; McLaughlin, Robert A

    2018-06-01

    In this paper, we develop and validate an open source, fully automatic algorithm to localize the left ventricular (LV) blood pool centroid in short axis cardiac cine MR images, enabling follow-on automated LV segmentation algorithms. The algorithm comprises four steps: (i) quantify motion to determine an initial region of interest surrounding the heart, (ii) identify potential 2D objects of interest using an intensity-based segmentation, (iii) assess contraction/expansion, circularity, and proximity to lung tissue to score all objects of interest in terms of their likelihood of constituting part of the LV, and (iv) aggregate the objects into connected groups and construct the final LV blood pool volume and centroid. This algorithm was tested against 1140 datasets from the Kaggle Second Annual Data Science Bowl, as well as 45 datasets from the STACOM 2009 Cardiac MR Left Ventricle Segmentation Challenge. Correct LV localization was confirmed in 97.3% of the datasets. The mean absolute error between the gold standard and localization centroids was 2.8 to 4.7 mm, or 12 to 22% of the average endocardial radius. Graphical abstract Fully automated localization of the left ventricular blood pool in short axis cardiac cine MR images.

  18. Monitoring of kratom or Krypton intake in urine using GC-MS in clinical and forensic toxicology.

    Science.gov (United States)

    Philipp, Anika A; Meyer, Markus R; Wissenbach, Dirk K; Weber, Armin A; Zoerntlein, Siegfried W; Zweipfenning, Peter G M; Maurer, Hans H

    2011-04-01

    The Thai medicinal plant Mitragyna speciosa (kratom) is misused as a herbal drug. Besides this, a new herbal blend has appeared on the drugs of abuse market, named Krypton, a mixture of O-demethyltramadol (ODT) and kratom. Therefore, urine drug screenings should include ODT and focus on the metabolites of the kratom alkaloids mitragynine (MG), paynantheine (PAY), speciogynine (SG), and speciociliatine (SC). The aim of this study was to develop a full-scan gas chromatography-mass spectrometry procedure for monitoring kratom or Krypton intake in urine after enzymatic cleavage of conjugates, solid-phase extraction, and trimethylsilylation. With use of reconstructed mass chromatography with the ions m/z 271, 286, 329, 344, 470, 526, 528, and 586, the presence of MG, 16-carboxy-MG, 9-O-demethyl-MG, and/or 9-O-demethyl-16-carboxy-MG could be indicated, and in case of Krypton, with m/z 58, 84, 116, 142, 303, 361, 393, and 451, the additional presence of ODT and its nor metabolite could be indicated. Compounds were identified by comparison with their respective reference spectra. Depending on the plant type, dose, administration route, and/or sampling time, further metabolites of MG, PAY, SG, and SC could be detected. The limits of detection (signal-to-noise ratio of 3) were 100 ng/ml for the parent alkaloids and 50 ng/ml for ODT. As mainly metabolites of the kratom alkaloids were detected in urine, the detectability of kratom was tested successfully using rat urine after administration of a common user's dose of MG. As the metabolism in humans was similar, this procedure should be suitable to prove an intake of kratom or Krypton.

  19. Sulpyrine inhalation challenge test monitored continuously by respiratory impedance and 81mKr ventilation image

    International Nuclear Information System (INIS)

    Suenaga, Naoto; Nakamura, Hitoshi; Shiratsuki, Natsuo; Nishioka, Yasuhiro; Kitada, Osamu; Sugita, Minoru

    1993-01-01

    Continuous changes of respiratory impedance by the oscillation method using Asthograph and 81m Kr ventilation image during saline and sulpyrine solution (100 mg/ml, 250 mg/ml) provocation were simultaneously measured in 15 adult asthmatics and 7 normal individuals. Estimation of airway obstruction by respiratory impedance using Asthograph was difficult during sulpyrine inhalation, since respiratory impedance increased gradually. In addition to the measurement of respiratory impedance, images of 81m Kr ventilation were also obtained to estimate the regional ventilatory distribution. Estimation of the airway obstruction was easily obtained. Another advantage of 81m Kr ventilation image is that it can estimate the regional ventilatory distribution. The site of airway obstruction provoked by sulpyrine was observed predominantly in the lower lung field. The results of our present study were as follows. In 3 patients, increase of respiratory impedance and defect of 81m Kr ventilation image were observed. Two cases in this group were clinically diagnosed as having aspirin-induced asthma. In 7 patients, a defect of 81m Kr ventilation image was observed, but no increase of respiratory impedance was observed. Five cases in this group could not be clinically diagnosed as having aspirin-induced asthma. In 5 patients, neither defect of 81m Kr ventilation image nor increase of respiratory impedance could be detected. These results suggest that 81m Kr ventilation image on sulpyrine inhalation challenge test is a useful method for evaluating regional ventilatory distribution, but should be further investigated for application to aspirin-induced asthma. (author)

  20. Measurement of sequential change of regional ventilation by new developed Kr-81m method in asthmatics

    International Nuclear Information System (INIS)

    Shimada, Takao; Narita, Hiroto; Ishida, Hirohide; Terashima, Yoichi; Hirasawa, Korenori; Mori, Yutaka; Kawakami, Kenji

    1991-01-01

    Fazio has reported the distribution of Kr-81m by the continuous inhalation method indicates distribution of ventilation. To estimate sequential ventilation change with the continuous Kr-81m inhalation method, it is necessary to keep the concentration of Kr-81m constant. However this is frequently ignored. Because of this, we have developed the new method to maintain constant concentration of Kr-81m and compared the reliability of this method to the conventional method. The results of phantom study showed that the concentration of Kr-81m is kept constant, and sequential change of ventilation can be estimated only by our new method. On application of this method in asthmatics, we have discovered the existence of the region where ventilation reduced by inhalation of a bronchodilator. (author)

  1. Clinical evaluation of Kr-81m inhalation study through a dead space

    International Nuclear Information System (INIS)

    Kurosawa, Hiromi; Matsubayashi, Satsuki; Ishii, Yasuko; Ishida, Hirohide; Hirasawa, Yukinori; Mori, Yutaka; Shimada, Takao; Kawakami, Kenji

    1990-01-01

    A new inhalation technique of 81m Kr gas was applied to evaluate the pathophysiological abnormality of ventilation. 81m Kr gas (370 MBq) was continuously supplied into a mouth piece directly (without dead space), V E , or through a dead space of 500 ml, V L , in 110 subjects with various lung diseases. Subjects were divided in four groups by a combination of distribution patterns of 81m Kr gas obtained by these two inhalation techniques. Group 1: No ventilatory defect in both techniques. Group 2: Defects larger in V E than V L . Group 3: Defects larger in V L than V E . Group 4: no remarkable difference in defects in both techniques. Cases of group 1 were normal in pulmonary function test and chest X-ray. Finding of group 2 reflects early airway closure. This group consisted of cases in remission of bronchial asthma, small air way disease and pulmonary congestion. In group 3, restrictive disease and obstructive disease, especially emphysema, were included. Patients with severe obstructive disease and organized change of pulmonary parenchyma were belonged in group 4. In ventilation study with 81m Kr gas, a combined study of inhalation technique through a dead space and by direct infusion may be useful to evaluate a pathophysiological change of various pulmonary diseases. (author)

  2. Scintigraphic diagnosis of gastrointestinal bleeding with 99mTc-labeled blood-pool agents

    International Nuclear Information System (INIS)

    Miskowiak, J.; Nielsen, S.L.; Munck, O.

    1981-01-01

    Abdominal scintigraphy with 99 mTc-labeled albumin or red blood cells was used in 68 patients to localize gastrointestinal bleeding or confirm that it had stopped. Acute, active bleeding was identified in 33 patients; characteristic patterns of bleeding from the stomach, biliary passages, small intestine, and colon are shown. Sensitivity was 0.86 (95% confidence limits, 0.57-0.98) and specificity was 1.0 (95% confidence limits, 0.82-1.0) in 33 patients who had scintigraphy and endoscopy performed in succession. Abdominal scintigraphy appears to be a valuable supplement to conventional diagnostic methods. In upper gastrointestinal bleeding, scintigraphy should be considered when endoscopy fails. In lower intestinal bleeding, scintigraphy should be the method of choice

  3. Cardiac tumours: non invasive detection and assessment by gated cardiac blood pool radionuclide imaging

    International Nuclear Information System (INIS)

    Pitcher, D.; Wainwright, R.; Brennand-Roper, D.; Deverall, P.; Sowton, E.; Maisey, M.

    1980-01-01

    Four patients with cardiac tumours were investigated by gated cardiac blood pool radionuclide imaging and echocardiography. Contrast angiocardiography was performed in three of the cases. Two left atrial tumours were detected by all three techniques. In one of these cases echocardiography alone showed additional mitral valve stenosis, but isotope imaging indicated tumour size more accurately. A large septal mass was detected by all three methods. In this patient echocardiography showed evidence of left ventricular outflow obstruction, confirmed at cardiac catheterisation, but gated isotope imaging provided a more detailed assessment of the abnormal cardiac anatomy. In the fourth case gated isotope imaging detected a large right ventricular tumour which had not been identified by echocardiography. Gated cardiac blood pool isotope imaging is a complementary technique to echocardiography for the non-invasive detection and assessment of cardiac tumours. (author)

  4. Diagnosis of Popliteal Venous Entrapment Syndrome by Magnetic Resonance Imaging Using Blood-Pool Contrast Agents

    International Nuclear Information System (INIS)

    Beitzke, Dietrich; Wolf, Florian; Juelg, Gregor; Lammer, Johannes; Loewe, Christian

    2011-01-01

    Popliteal vascular entrapment syndrome is caused by aberrations or hypertrophy of the gastrocnemius muscles, which compress the neurovascular structures of the popliteal fossa, leading to symptoms of vascular and degeneration as well as aneurysm formation. Imaging of popliteal vascular entrapment may be performed with ultrasound, magnetic resonance imaging (MRI), computed tomography angiography, and conventional angiography. The use of blood-pool contrast agents in MRI when popliteal vascular entrapment is suspected offers the possibility to perform vascular imaging with first-pass magnetic resonance angiographic, high-resolution, steady-state imaging and allows functional tests all within one examination with a single dose of contrast agent. We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI.

  5. Krypton Adsorption on Zeolite-Templated Carbon and Anomalous Surface Thermodynamics.

    Science.gov (United States)

    Murialdo, Maxwell; Stadie, Nicholas P; Ahn, Channing C; Fultz, Brent

    2015-07-28

    Krypton adsorption was measured at eight temperatures between 253 and 433 K on a zeolite-templated carbon and two commercial carbons. The data were fitted using a generalized Langmuir isotherm model and thermodynamic properties were extracted. Differing from that on commercial carbons, krypton adsorption on the zeolite-templated carbon is accompanied by an increasing isosteric enthalpy of adsorption, rising by up to 1.4 kJ mol(-1) as a function of coverage. This increase is a result of enhanced adsorbate-adsorbate interactions promoted by the ordered, nanostructured surface of the adsorbent. An assessment of the strength and nature of these adsorbate-adsorbate interactions is made by comparing the measured isosteric enthalpies of adsorption (and other thermodynamic quantities) to fundamental metrics of intermolecular interactions of krypton and other common gases.

  6. Technical Note: Calibration device for the krypton hygrometer KH20

    Directory of Open Access Journals (Sweden)

    T. Foken

    2012-08-01

    Full Text Available A calibration device for krypton hygrometers (KH20, Campbell Scientific, Inc. with variable path length is presented. This unit allows for in-situ calibrations of the krypton hygrometer, which is typically not very stable over time, during measuring campaigns. It was constructed mainly for application at high altitudes and low temperatures, where further improvements are needed to the IR-hygrometers which are normally used. The changing path length requires that a changing concentration of the absorber be simulated. Because oxygen absorbs more strongly than water vapour, the calibration is made against oxygen and transferred to water vapour. The design of the calibration instrument is made as one unit containing a stepper motor system, PC and humidity sensor. For the calibration, it is necessary to install the krypton hygrometer on this unit.

  7. Krypton and xenon in the atmosphere of Venus

    Science.gov (United States)

    Donahue, T. M.; Hoffman, J. H.; Hodges, R. R., Jr.

    1981-01-01

    The paper reports a determination by the Pioneer Venus large probe neutral mass spectrometer of upper limits to the concentration of krypton and xenon along with most of their isotopes in the atmosphere of Venus. The upper limit to the krypton mixing ratio is estimated at 47 ppb, with a very conservative estimate at 69 ppb. The probable upper limit to the sum of the mixing ratios of the isotopes Xe-128, Xe-129, Xe-130, Xe-131, and Xe-132 is 40 ppb by volume, with a very conservative upper limit three times this large.

  8. Preliminary safety evaluation of a commercial-scale krypton-85 encapsulation facility

    International Nuclear Information System (INIS)

    Christensen, A.B.; Tanner, J.E.; Knecht, D.A.

    1980-09-01

    This report demonstrates that a commercial-scale facility for encapsulating krypton-85 in zeolite-5A or glass at a 2000 MTHM per year nuclear fuel reprocessing plant can be designed to contain fragments and the 340 to 850 kCi krypton-85 inventory from an assumed catastrophic failure of the high pressure vessel. The vessel failure was assumed as a worst case and was not based on a detailed design evaluation or operating experience. The process design is based on existing commercial hot isostatic pressing technology operated at up to 40 times the scale required for krypton encapsulation. From the calculated process gas inventory in the pressure vessel and vessel design, the explosive energy of 8.4 kg TNT and vessel plug and fragment velocities were calculated. The facility Containment Cell housing the high pressure vessel was designed to contain the gases, fragments, and the shock wave energy calculated for vessel failure. The Access Cell located directly above the Containment Cell was designed to be a tertiary confinement of krypton-85, should the access hatch be breached

  9. The September 2017 M=8.1 Chiapas and M=7.1 Puebla, Mexico, earthquakes: Chain reaction or coincidence?

    Science.gov (United States)

    Toda, S.; Stein, R. S.

    2017-12-01

    The M=8.1 and M=7.1 events struck 12 days and 600 km apart, both with an independent probability of occurrence of 0.5% per year, based on the GEAR model [Bird et al., 2015]. Are they related? First, we calculated the static stress imparted by the M=8.1 shock to the fault that ruptured in the M=7.1, and find a tiny push that would favor rupture. But the stress increase (0.2 kPa) is less than the fault would experience from the tidal stresses, and so it should be inconsequential. We next used the México Servicio Sismológico Nacional (UNAM) online catalog to look at the quakes in the month before the M=8.1 and in the 13 days since. We calculate the completeness to be M≥4.0. There are virtually no remote aftershocks from the Chiapas rupture that extend within 250 km of the M=7.1 shock during the first week after the M=8.1. So, if anything, the M=8.1 turned off for a week or more the region that ruptured in the M=7.1. Events started turning on about 2-3 days before the M=7.1, but none of those struck within 40 km of the future M=7.1 mainshock. The seismic surface waves unleashed by great earthquakes envelop the globe in just 160 minutes, and yet triggering of remote large aftershocks during these 2-3 hours is either very rare [Pollitz et al., Nature 2012] or in dispute [Fan & Shearer, 2016 vs. Yue et al., 2017]. So, the waves must trigger tiny shocks that cascade into larger shocks after some delay. Or, perhaps the stresses conveyed by the waves pump pockets of fluids that slowly diffuse into nearby fault zones, lubricating them to the point of failure [Parsons at al., 2017]. In the cases where great earthquakes are indisputably seen to trigger aftershocks at great distances or even globally, they to do so within several days, or a week at most. Since Puebla struck 12 days later, this seems to us too long a period to be explained by dynamic triggering. Even though neither quake on their own is rare, what's the chance of independent M=8.1 and M=7.1 events just 12

  10. Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT. Can we use the same reference database?

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Yamaguchi, Hitoshi; Tsujimura, Eiichiro; Nishimura, Tsunehiko [Osaka Univ., Suita (Japan). Graduate School of Medicine

    2000-04-01

    The purpose of this study was to compare left ventricular (LV) volume and ejection fraction (LVEF) measurements obtained with electrocardiographic gated single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (GS-MPI) with those obtained with gated SPECT cardiac blood-pool imaging (GS-pool). Fifteen patients underwent GS-MPI with technetium-99m tetrofosmin and GS-pool with technetium-99m-erythrocyte, within a mean interval of 8{+-}3 days. Eight patients had suspected dilated cardiomyopathy and seven patients had angiographically significant coronary artery disease. End-diastolic volume (EDV), end-systolic volume (ESV) and LVEF measurements were estimated from GS-MPI images by means of Cedars-Sinai automatic quantitative program and from GS-pool images by the threshold technique. Mean differences between GS-MPI and GS-pool in EDV, ESV and LVEF measurements were -2.8{+-}10.5 ml [95% confidence interval (CI): -8.6{+-}3.0 ml], 2.6{+-}7.3 ml (CI: -1.4-6.6 ml) and -2.3{+-}5.1% (CI: -5.1-0.6%), respectively. No significant difference in the mean differences from 0 was found for EDV, ESV or LVEF measurements. Bland-Altman plots revealed no trend over the measured LV volumes and LVEF. For all parameters, regression lines approximated lines of identity. The excellent agreement between GS-MPI and GS-pool measurements suggests that, for estimation of LV volumes and LVEF, these two techniques may be used interchangeably and measurements by one method can serve as a reference for the other. (author)

  11. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Joyce T. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Robinson, Joshua D. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Deng, Jie [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Rigsby, Cynthia K. [Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States)

    2016-12-15

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  12. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Johnson, Joyce T.; Robinson, Joshua D.; Deng, Jie; Rigsby, Cynthia K.

    2016-01-01

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  13. Gallium-68-DOTA-albumin as a PET blood-pool marker: experimental evaluation in vivo

    International Nuclear Information System (INIS)

    Hoffend, Johannes; Mier, Walter; Schuhmacher, Jochen; Schmidt, Kerstin; Dimitrakopoulou-Strauss, Antonia; Strauss, Ludwig G.; Eisenhut, Michael; Kinscherf, Ralf; Haberkorn, Uwe

    2005-01-01

    Investigations into tumor angiogenesis and antiangiogenic treatment have renewed interest in tumor perfusion. To image tumor blood-pool by PET, suitable tracers are not generally available. In this experimental study, we characterized a 68 Ga-labeled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) conjugate of rat serum albumin ( 68 Ga-DOTA-RSA) in vivo using a generator-produced isotope. Biodistribution was determined in ACI rats after intravenous administration of 3-6 MBq of 68 Ga-DOTA-RSA. Three ACI rats were imaged over 1 h by dynamic PET after intravenous administration of 15-25 MBq of 68 Ga-DOTA-RSA while the blood-pool activity was recorded simultaneously in a closed extracorporeal loop (ECL) between the carotid artery and the jugular vein. Time-activity curves (TACs) were obtained from volume of interest (VOI) analysis and from the ECL data. Stability and metabolites in plasma and urine were analyzed by size exclusion HPLC (SE-HPLC) 1 h after intravenous injection of 67 Ga-DOTA-RSA. Blood radioactivity decreased by 10% and 18% from 10 to 60 min p.i. by biodistribution and PET or ECL, respectively. Tissue sampling between 10 and 60 min p.i. showed slight increases in the uptake of spleen, myocardium, kidney and skeletal muscle while hepatic accretion remained unchanged. Total urinary excretion after 60 min amounted to 9% of the injected dose. HPLC demonstrated a single urinary metabolite corresponding in size to gallium-labeled DOTA. 68 Ga-DOTA-RSA is a blood-pool tracer whose physical and biological half-life is well suited for PET. Our findings support clinical imaging using 68 Ga-DOTA-labeled human serum albumin (HSA). The generator-produced label makes 68 Ga-DOTA-labeled albumin continuously available even to centers lacking an in-house cyclotron

  14. Accurate ab initio potential for the krypton dimer and transport properties of the low-density krypton gas.

    Science.gov (United States)

    Waldrop, Jonathan M; Song, Bo; Patkowski, Konrad; Wang, Xiaopo

    2015-05-28

    A new highly accurate potential energy curve for the krypton dimer was constructed using coupled-cluster calculations up to the singles, doubles, triples, and perturbative quadruples level, including corrections for core-core and core-valence correlation and for relativistic effects. The ab initio data points were fitted to an analytic potential which was used to compute the most important transport properties of the krypton gas. The viscosity, thermal conductivity, self-diffusion coefficient, and thermal diffusion factor were calculated by the kinetic theory at low density and temperatures from 116 to 5000 K. The comparisons with literature experimental data as well as with values from other pair potentials indicate that our new potential is superior to all previous ones. The transport property values computed in this work are recommended as standard values over the complete temperature range.

  15. Solubility of krypton in liquid CO2

    International Nuclear Information System (INIS)

    Notz, K.J.; Meservey, A.B.

    1976-06-01

    The solubility of krypton in liquid CO 2 was measured experimentally over essentially the entire liquid range of CO 2 , from -53 to 29 0 C. A tracer technique using 85 Kr was employed, and equilibrated gas-liquid samples were analyzed in situ with a collimated counter. Dilute concentrations of krypton were used, and the data are expressed as a distribution ratio, Y/sub Kr//X/sub Kr/, the log of which is nearly linear with respect to temperature from the lowest temperature to about 20 0 C, above which the values fall off rapidly toward a value of unity at the critical temperature. The numerical values obtained for the distribution ratio increase from 1.44 at 29 0 C to 29.4 at -53 0 C

  16. Immobilization of krypton in a metal matrix

    International Nuclear Information System (INIS)

    Whitmell, D.S.

    1987-01-01

    The report presents the work carried out on the immobilization of krypton in a metallic matrix by combined ion implantation and sputtering. The process has been successfully tested using 100 curies of fully active krypton in order to demonstrate that the process operates in the radiation levels which will be obtained with active gas at a reprocessing plant. A design study for a plant for fuel reprocessing has shown that the process can be simply operated, without requiring shielded cells. These results, which complete the development programme, indicate that the process is ideal for the containment of kripton arising from the processing of nuclear fuel and that the product will retain the gas under normal storage conditions and also during simulated accident conditions

  17. Occlusion and storage of krypton in solids

    International Nuclear Information System (INIS)

    Vansant, E.F.; Thijs, A.; Peeters, G.; Bievre, P. de; Verhaert, I.

    1984-01-01

    The modification process in order to change in a controlled way the effective pore size of zeolites was optimized by investigating the reaction conditions such as degree of chemisorption, reaction temperature, extent of primary/secondary reactions, type of modifying agent, type of substrate, etc. Different reaction and adsorption conditions have been tested to increase the thermal stability of encapsulated krypton in modified zeolites. The possibilities for zeolite modification have been enlarged by combining boranation and silanation with a thermal treatment of sepiolite, and by the formation of boron-nitrogen compounds in zeolites. Screening experiments, on a semi-industrial scale, of the krypton removal from air were carried out. Two kinds of Kr/air separation have been tested suscessfully on modified mordenite

  18. Relativistic Multichannel Treatment of Krypton Spectra across the First Ionization Threshold

    Institute of Scientific and Technical Information of China (English)

    QU Yi-Zhi; PENG Yong-Lun

    2005-01-01

    @@ The relativistic multichannel theory has been extended to calculate both the eigen quantum defects μα, transformation matrix Uiα, and the eigen dipole matrix elements Dα of krypton. The Rydberg and autoionizationspectra of krypton across the first ionization threshold are calculated within the framework of multichannel quantum defect theory. Our calculated spectra are in agreement with the absolute measurement data.

  19. Prediction of cardiac sympathetic nerve activity and cardiac functional outcome after treatment in patients with dilated cardiomyopathy. Examination using dobutamine gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu; Toyama, Takuji; Iwasaki, Tsutomu; Suzuki, Tadashi [Gunma Univ., Maebashi (Japan). School of Medicine; Hoshizaki, Hiroshi; Oshima, Shigeru; Taniguchi, Koichi; Nagai, Ryozo

    2000-07-01

    This study evaluated whether dobutamine gated blood pool scintigraphy can predict improvement of cardiac sympathetic nerve activity and cardiac function. Sixteen patients (10 men and 6 women, mean age 59{+-}13 years) with dilated cardiomyopathy underwent dobutamine gated blood pool scintigraphy to measure left ventricular ejection fraction (LVEF) using tracer at 0, 5, 10 and 15 {mu}g/kg/min before treatment. Patients were divided into good responders (LVEF increase {>=}15%) 8 patients (GR Group) and poor responders (LVEF increase <15%) 8 patients (PR Group) after treatment with {beta}-blocker or amiodarone with a background treatment of digitalis, diuretics and angiotensin converting enzyme inhibitor. I-123 metaiodobenzylguanidine (MIBG) imaging to evaluate cardiac sympathetic nerve activity and echocardiography were performed before and at one year after treatment. MIBG imaging was obtained 4 hours after tracer injection, and the heart/mediastinum count ratio (H/M ratio) calculated from the anterior planar image and the total defect score (TDS) from the single photon emission computed tomography image. LVEF and left ventricular endo-diastolic dimension (LVDd) were measured by echocardiography and New York Heart Association (NYHA) functional class was evaluated. The GR Group showed TDS decreased from 28{+-}6 to 17{+-}12 (p<0.05), H/M ratio increased from 1.79{+-}0.26 to 2.07{+-}0.32 (p<0.05), LVEF increased from 29{+-}8% to 48{+-}10% (p<0.01), and LVDd decreased from 65{+-}4 mm to 58{+-}5 mm (p<0.05). In contrast, the PR group showed no significant changes in TDS. H/M ratio, LVEF and LVDd. NYHA functional class improved in both groups. The improvement was better in the GR Group than in the PR group. Dobutamine gated blood pool scintigraphy is useful to predict the improvement of the cardiac sympathetic nerve activity and cardiac function, and symptoms after treatment in patients with dilated cardiomyopathy. (author)

  20. Krypton red laser photocoagulation of the ocular fundus. 1982.

    Science.gov (United States)

    Yannuzzi, Lawrence A; Shakin, Jeffrey L

    2012-02-01

    The theoretical rationale, the histopathologic evidence, and the preliminary clinical studies related to krypton red laser (KRL) photocoagulation of the ocular fundus are reviewed. The authors report on their experience with currently available laser systems using this wavelength (647.1 nm) for photocoagulation of retinal vascular proliferative diseases and chorioretinal diseases associated with exudative manifestations. A histopathologic and clinical comparison of argon blue-green laser (ABGL), the pure argon green laser (AGL), and the krypton yellow laser (KYL), with reference to photocoagulation treatment of the ocular fundus is also discussed.

  1. Gated cardiac blood pool studies in atrial fibrillation: Role of cycle length windowing

    Energy Technology Data Exchange (ETDEWEB)

    Wallis, J W; Juni, J E; Wu, L [Michigan Univ., Ann Arbor (USA). Div. of Nuclear Medicine

    1991-01-01

    Cycle length windowing is gaining increasing acceptance in gated blood pool imaging of patients with atrial fibrillation (AF). The goals of this study were: to assess differences of ejection fraction (EF) in AF with and without windowing and to determine how EF varied with cycle length in patients with AF. Twenty patients with AF were prospectively studied by gated blood pool imaging, with simultaneous collection in each patient of 5-7 studies with cycle length windows spanning the cycle length histogram. Each window accepted beats of only a narrow range of cycle lengths. EF was determined for each of the narrow cycle length windows as well as for the entire gated blood pool study without cycle length windowing. For every patient an average of the windowed EFs was compared with the non-windowed EF. EF values were similar (mean windowed: 46.6; non-windowed: 45.5; P=0.16), and there was a good correlation between the two techniques (r=0.97). The data were then examined for a relationship of EF with cycle length. The difference from average windowed EF ({Delta}EF) was calculated for each window and plotted vs. the cycle length of the center of each window. No predictable linear or nonlinear relationship of {Delta}EF with window position was observed. Lack of predictable variation of EF with cycle length is likely due to lack of a predictable amount of ventricular filling for a given cycle length, as the amount of diastolic filling in AF depends on the random cycle length of the preceding beat. In summary, windowing in AF does not provide a clinically significant difference in EF determination. If cycle length windowing is used, the exact location of the window is not critical. (orig.).

  2. Trapping of deuterium in krypton-implanted nickel

    International Nuclear Information System (INIS)

    Frank, R.C.; McManus, S.P.; Rehn, L.E.; Baldo, P.

    1986-01-01

    Krypton ions with energy 600 keV were implanted in nickel to fluences of 2 x 10 16 cm -2 under three different conditions. Deuterium was subsequently introduced into the implanted regions by electrolysis at room temperature. After the diffusible deuterium was permitted to escape, the 2 H( 3 He, 1 H) 4 He nuclear reaction was used to analyze for the trapped deuterium during an isochronal annealing program. The region implanted at 100 0 C with no higher temperature anneal had the largest number of traps; the region implanted at 100 0 C and annealed for 100 min at 500 0 C had considerably less; the region implanted at 500 0 C had the least. Electron diffraction patterns confirmed the existence of solid crystalline krypton in all three regions. Transmission electron microscope studies revealed precipitates with an average diameter of 8 nm in the region implanted at 500 0 C. The two regions implanted at 100 0 C contained smaller precipitates. Trap binding enthalpies were obtained by math modeling. In addition to the traps with binding enthalpy of 0.55 eV reported earlier by other investigators for helium implanted in nickel, a smaller number of traps with binding enthalpies up to 0.83 eV were also found. The trapping of deuterium by various types of imperfections, including the solid krypton precipitates, is discussed

  3. Preliminary safety evaluation of a commercial-scale krypton-85 encapsulation facility

    International Nuclear Information System (INIS)

    Christensen, A.B.; Tanner, J.E.; Knecht, D.A.

    1980-01-01

    This paper demonstrates that a commercial-scale facility for encapsulating krypton-85 in zeolite-5A or glass at a 2000 MTHM per year nuclear fuel reprocessing plant can be designed to contain fragments and the 340 to 850 kCi krypton-85 inventory from an assumed catastrophic failure of the high pressure vessel. The vessel failure was assumed as a worst case and was not based on a detailed design evaluation or operating experience. The process design is based on existing commercial hot isostatic pressing technology operated at up to 40 times the scale required for krypton encapsulation. From the calculated process gas inventory in the pressure vessel and vessel design, the maximum explosive energy of 8.4 kg TNT and resulting vessel plug and fragment velocities were calculated. The facility Containment Cell housing the high pressure vessel was designed to contain the gases, fragments, and the shock wave energy calculated for a hypothetical vessel failure. The Access Cell located directly above the Containment Cell was designed to be a tertiary confinement of krypton-85, should the access hatch be breached. 3 figures, 2 tables

  4. Effects of control technology on the projected krypton-85 environmental inventory

    International Nuclear Information System (INIS)

    Oscarson, E.E.

    1973-01-01

    Growth projections for the USA nuclear power industry may be used to make projections of future radioactive material inventories available for potential release to the environment. Since krypton-85 is produced in reactors, the potential routes of release to the environment are at the reactors or the fuel reprocessing plants. The present generation of reactors and fuel reprocessing plants do not use any systems to limit the release of krypton-85 into the biosphere. Clean-up systems are currently being designed and could be introduced when necessary. The cumulative inventory of krypton-85 in the environment is dependent upon the time of introduction of these clean-up systems and their efficiencies, in addition to the total quantity produced. Annual and cumulative inventories of krypton-85 are projected to increase dramatically over the next 50 years. If controls are assumed to be initiated at various years, a series of graphs of different cumulative environmental inventories and the associated doses and health effects are drawn. Varying the year of introduction and the efficiency of these systems allows one to speculate as to the optimum time for control implementation

  5. Chemical contaminants in the 81Rb→/sup 81m/Kr generator arising from target deterioration

    International Nuclear Information System (INIS)

    Finn, R.D.; Vora, M.; Boothe, T.; Kothari, P.; Emran, A.

    1985-01-01

    A cyclotron adjunct to a large medical center is an extremely useful tool in the armamentarium for basic biomedical research and clinical applications. However, specific quality assurances must be applied to diagnostic radionuclides that are routinely prepared. The lack of data on the toxicity of a variety of fabrication materials used for the preparation of an automated cyclotron processing system, such as the 81 Rb→/sup 81m/Kr generator system, should be of concern. Of paramount importance is the design of an efficient and reproducible system requiring minimal maintenance. The stability of various components toward their surroundings, resistance to radiation damage, and temperature considerations must be addressed. In spite of conscientious planning, problems arise when unanticipated chemical moieties formed either from electrolytic and/or radiolytic processes appear. The authors experience with these unexpected species, as well as a hypothetical explanation of their origin, are presented

  6. The values of myocardial tomography imaging and gated cardiac blood pool imaging in detecting left ventricular aneurysm

    International Nuclear Information System (INIS)

    Zhu Mei; Pan Zhongyun; Li Jinhui

    1992-01-01

    The sensitivity and specificity of myocardial tomography imaging and gated cardiac blood-pool imaging in detecting LVA were studied in 36 normal subjects and 68 patients with myocardial infarction. The sensitivities of exercise and rest myocardial imaging in detecting LVA were 85% and 77.3% respectively. The specificity of both is 95.5%. The sensitivity of cinema display, phase analysis and left ventricular phase shift in evaluating LVA were 86.7%, 86.7%, 100% respectively. Their specificity were all 100%. It is concluded that blood pool imaging is of choice for the diagnosis of LVA, and that myocardial imaging could also demonstrate LVA during diagnosing myocardial infarction

  7. Auger measurements on the two-dimensional adsorption of krypton on graphite

    International Nuclear Information System (INIS)

    Kramer, H.M.; Suzanne, J.

    1975-01-01

    The adsorption of krypton on a (0001) plane of graphite was studied by means of Auger Electron Spectroscopy. The spectrum of krypton in the energy range from 5eV to 11eV and from 30eV to 70eV is reported. By means of LEED a √3x√3 superstructure is found for the adsorbed monolayer of Kr [fr

  8. Ventricular function during the acute rejection of heterotopic transplanted heart: Gated blood pool studies

    International Nuclear Information System (INIS)

    Valette, H.; Bourguignon, M.H.; Desruennes, M.; Merlet, P.; Le Guludec, D.; Syrota, A.

    1991-01-01

    Twenty patients who had undergone a heterotopic heart transplant were studied prospectively to determine the relationship between rejection and ventricular dysfunction assessed from gated blood pool studies. A fully automated method for detecting ventricular edges was implemented; its success rate for the grafted left and right ventricles was 94% and 77%, respectively. The parameters, peak ejection and filling rates, were calculated pixel per pixel using a two-harmonic Fourier algorithm and then averaged over the ventricular region of interest. Peak filling and ejection rates were closely related with the severity of the rejection, while the left ventricular ejection fraction was not. Peak filling rates of both ventricles were the indices closely related to the presence of moderate rejection. Despite the low number of patients, these data suggested that gated blood pool derived indices of ventricular function are associated with ventricular dysfunction resulting from myocarditis rejection. Radionuclide ventriculography provides parametric data which are accurate and reliable for the diagnosis of rejection. (orig.)

  9. Dynamic circular buffering: a technique for equilibrium gated blood pool imaging.

    Science.gov (United States)

    Vaquero, J J; Rahms, H; Green, M V; Del Pozo, F

    1996-03-01

    We have devised a software technique called "dynamic circular buffering" (DCB) with which we create a gated blood pool image sequence of the heart in real time using the best features of LIST and FRAME mode methods of acquisition/processing. The routine is based on the concept of independent "agents" acting on the timing and position data continuously written into the DCB. This approach allows efficient asynchronous operation on PC-type machines and enhanced capability on systems capable of true multiprocessing and multithreading.

  10. 10 CFR 32.22 - Self-luminous products containing tritium, krypton-85 or promethium-147: Requirements for license...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Self-luminous products containing tritium, krypton-85 or... containing tritium, krypton-85 or promethium-147: Requirements for license to manufacture, process, produce... self-luminous products containing tritium, krypton-85, or promethium-147, or to initially transfer such...

  11. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. I

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Dillinger, P.; Harangozo, M.; Jombik, J.

    1980-01-01

    A method for the determination of salicylic, acetylsalicylic and benzoic acids in officinal pharmaceutical based on radiometric titration with 0.1 mol.l -1 NaOH was developed. The end-point was detected with the aid of radioactive glass kryptonate. After the end-point, the excess titrant attacks the glass surface layers and this results in releasing 85 Kr, and consequently, in decreasing the radioactivity of the kryptonate employed. The radioactive kryptonate used as an indicator was prepared by the bombardment of glass with accelerated 85 Kr ions. The developed method is simple, accurate and correct. (author)

  12. Krypton separation from ambient air for application in collinear fast beam laser spectroscopy.

    Science.gov (United States)

    Mohamed, Tarek; Strohaber, James; Nava, Ricardo; Kolomenskii, Alexandre; Thonnard, Norbert; Schuessler, Hans A

    2012-07-01

    A portable apparatus for the separation of krypton from environmental air samples was tested. The apparatus is based on the cryogenic trapping of gases at liquid nitrogen temperature followed by controlled releases at higher temperatures. The setup consists of a liquid nitrogen trap for the removal of H(2)O and CO(2), followed by charcoal-filled coils that sequentially collect and release krypton and other gases providing four stages of gas chromatography to achieve separation and purification of krypton from mainly N(2), O(2), and Ar. Residual reactive gases remaining after the final stage of chromatography are removed with a hot Ti sponge getter. A thermal conductivity detector is used to monitor the characteristic elution times of the various components of condensed gases in the traps during step-wise warming of the traps from liquid nitrogen temperatures to 0 °C, and then to 100 °C. This allows optimizing the switching times of the valves between the stages of gas chromatography so that mainly krypton is selected and loaded to the next stage while exhausting the other gases using a He carrier. A krypton separation efficiency of ~80 % was determined using a quadrupole mass spectrometer.

  13. Extreme-ultraviolet wavelength and lifetime measurements in highly ionized krypton

    CERN Document Server

    Kukla, K W; Vogt, C M V; Berry, H G; Dunford, R W; Curtis, L J; Cheng, S

    2005-01-01

    We have studied the spectrum of highly ionized krypton in the extreme-ultraviolet wavelength region (50-300 Aa), using beam-foil excitation of fast krypton ions at the Argonne ATLAS accelerator facility. We report measurements of transition wavelengths and excited-state lifetimes for n=2 states in the lithiumlike, berylliumlike, and boronlike ions, Kr/sup 31+,32+,33+/. Excited state lifetimes ranging from 10 ps to 3 ns were measured by acquiring time- of-flight-delayed spectra with a position-sensitive multichannel detector.

  14. Surface temperature measurement with radioactive kryptonates

    International Nuclear Information System (INIS)

    Pruzinec, J.; Piatrik, M.

    1976-01-01

    The preparation and use of radioactive kryptonates is described for measuring surface temperatures within the region of 45 to 70 degC. Two samples each were prepared of kryptonated beechwood and hydroquinone on a paper carrier. One sample served as the standard which during the experiment was placed in a thermostat at a constant temperature of 45 degC. The second sample was placed in another thermostat where the temperature changed from 45 to 70 degC. Both samples were in the thermostat for 30 mins. The temperature was raised in steps of 2.5 degC and the time of measurement was constant in both samples. The dependences are given of the drop in activity on temperature for both types of samples. The difference was determined of the drop in activity between the standard and the second sample and the relation for measuring the temperature of the sample was determined therefrom. (J.B.)

  15. Gd-DTPA L-cystine bisamide copolymers as novel biodegradable macromolecular contrast agents for MR blood pool imaging.

    Science.gov (United States)

    Kaneshiro, Todd L; Ke, Tianyi; Jeong, Eun-Kee; Parker, Dennis L; Lu, Zheng-Rong

    2006-06-01

    The purpose of this study was to synthesize biodegradable Gd-DTPA L-cystine bisamide copolymers (GCAC) as safe and effective, macromolecular contrast agents for magnetic resonance imaging (MRI) and to evaluate their biodegradability and efficacy in MR blood pool imaging in an animal model. Three new biodegradable GCAC with different substituents at the cystine bisamide [R = H (GCAC), CH2CH2CH3 (Gd-DTPA L-cystine bispropyl amide copolymers, GCPC), and CH(CH3)2 (Gd-DTPA cystine bisisopropyl copolymers, GCIC)] were prepared by the condensation copolymerization of diethylenetriamine pentaacetic acid (DTPA) dianhydride with cystine bisamide or bisalkyl amides, followed by complexation with gadolinium triacetate. The degradability of the agents was studied in vitro by incubation in 15 microM cysteine and in vivo with Sprague-Dawley rats. The kinetics of in vivo contrast enhancement was investigated in Sprague-Dawley rats on a Siemens Trio 3 T scanner. The apparent molecular weight of the polydisulfide Gd(III) chelates ranged from 22 to 25 kDa. The longitudinal (T1) relaxivities of GCAC, GCPC, and GCIC were 4.37, 5.28, and 5.56 mM(-1) s(-1) at 3 T, respectively. The polymeric ligands and polymeric Gd(III) chelates readily degraded into smaller molecules in incubation with 15 microM cysteine via disulfide-thiol exchange reactions. The in vitro degradation rates of both the polymeric ligands and macromolecular Gd(III) chelates decreased as the steric effect around the disulfide bonds increased. The agents readily degraded in vivo, and the catabolic degradation products were detected in rat urine samples collected after intravenous injection. The agents showed strong contrast enhancement in the blood pool, major organs, and tissues at a dose of 0.1 mmol Gd/kg. The difference of their in vitro degradability did not significantly alter the kinetics of in vivo contrast enhancement of the agents. These novel GCAC are promising contrast agents for cardiovascular and tumor MRI

  16. Electron excitation coefficients of neutral and ionic levels of krypton in Townsend discharges

    International Nuclear Information System (INIS)

    Malovic, G.N.; Strinic, A.I.; Petrovic, Z.Lj.; Sadeghi, N.

    2006-01-01

    In this paper, we present experimental results for excitation coefficients of krypton atoms to several Kr and Kr + excited levels for E/N (electric field to gas particle number density ratio usually in units of Townsend, 1 Td = 10 -21 V m 2 ) values from 7 x 10 -20 V m 2 to above 1 x 10 -17 V m 2 . The data have been obtained in two different parallel plate self-sustained Townsend discharge drift tubes. The spatial distribution of the emission intensities were recorded and then normalized to give excitation coefficients at the anode, by using the electron flux at this point. The values of these coefficients are placed on an absolute scale by using a standard tungsten ribbon lamp calibrated against a primary blackbody radiation standard. The ionization rates at different E/N are obtained from the spatial emission profiles. The data for atomic krypton levels 2p 2 , 2p 3 , 2p 5 , 2p 6 , 2p 7 , 2p 8 , 3p 5 and 3p 6 (in Paschen notation) were converted to excitation coefficients by using quenching coefficients from the literature. The emission coefficients of eight 4s 2 4p 4 ( 3 P)5p levels of Kr + have also been measured for E/N values from about 1 x 10 -18 V m 2 up to nearly 8 x 10 -18 V m 2

  17. Effect of solvent/detergent-treated pooled plasma on fibrinolysis in reconstituted whole blood.

    Science.gov (United States)

    Saadah, Nicholas H; van der Meer, Pieter F; Brinkman, Herm Jan M; de Korte, Dirk; Bontekoe, Ido J; Korsten, Herbert H; Middelburg, Rutger A; van der Bom, Johanna G; Schipperus, Martin R

    2017-10-01

    Hyperfibrinolysis has been observed in patients heavily transfused with solvent/detergent-treated pooled plasma (S/D plasma). We compared coagulation and fibrinolytic variables in blood containing S/D plasma with blood containing fresh-frozen plasma (FFP), with and without α2-antiplasmin or tranexamic acid (TXA) supplementation. Whole blood samples were reconstituted from red blood cells, platelet (PLT) concentrates, and varying mixtures of FFP and S/D plasma. Hematocrit and PLT count of reconstituted whole blood samples were varied. For a subset of runs, α2-antiplasmin or TXA was added to S/D plasma whole blood samples. Thromboelastography (TEG) analysis was performed to assess 50% clot lysis time (CLT 50% ), maximum amplitude (MA), and initial clotting time (R-time). The change in CLT 50% of whole blood as the plasma compartment transitions from FFP to S/D plasma was -52% (95% confidence interval [CI], -60% to -45%; p plasma in whole blood. α2-Antiplasmin and TXA restored clot lysis time in S/D plasma whole blood. Whole blood with S/D plasma has shorter clot lysis times in vitro compared to whole blood with FFP. α2-Antiplasmin and TXA restore clot lysis time of S/D plasma whole blood to that of FFP whole blood. Clinicians should be aware of the decreased clot lysis time associated with S/D plasma transfusion. © 2017 AABB.

  18. Liquid--vapor isotope fractionation factors in argon--krypton binary mixtures

    International Nuclear Information System (INIS)

    Lee, M.W.; Neufeld, P.; Bigeleisen, J.

    1977-01-01

    An equilibrium isotope effect has been studied as a continuous function of the potential field acting on the atom undergoing isotopic exchange. This has been accomplished through a study of the liquid vapor isotope fractionation factors for both, 36 Ar/ 40 Ar and 80 Kr/ 84 Kr in a series of binary mixtures which span the range between the pure components at 117.5 0 K. The 36 Ar/ 40 Ar fractionation factor increases (linearly) from (lnα)2.49 x 10 -3 in pure liquid argon to 2.91 x 10 -3 in an infinitely dilute solution in liquid krypton. Conversely, the 80 Kr/ 84 Kr fractionation factor decreases (linearly) from (lnα)0.98 x 10 -3 in pure liquid krypton to 0.64 x 10 -3 in an infinetely dilute solution in pure liquid argon. The mean force constants 2 U>/sub c/ on both argon and krypton atoms in the mixtures are derived from the respective isotope fractionation factors.The mean force constants for argon and krypton as a function of composition have been calculated by a modified corresponding states theory which uses the pure liquids as input parameters. The discrepancy is 8 percent at X/sub Ar/ + O. A systematic set of calculations has been made of 2 U> (Ar) and 2 U> (Kr) as a function of composition using radial distribution functions generated by the Weeks--Chandler--Anderson perturbation theory

  19. High-Pressure Reactivity of Kr and F2—Stabilization of Krypton in the +4 Oxidation State

    Directory of Open Access Journals (Sweden)

    Dominik Kurzydłowski

    2017-10-01

    Full Text Available Since the synthesis of the first krypton compound, several other Kr-bearing connections have been obtained. However, in all of them krypton adopts the +2 oxidation state, in contrast to xenon which forms numerous compounds with an oxidation state as high as +8. Motivated by the possibility of thermodynamic stabilization of exotic compounds with the use of high pressure (exceeding 1 GPa = 10 kbar, we present here theoretical investigations into the chemistry of krypton and fluorine at such large compression. In particular we focus on krypton tetrafluoride, KrF4, a molecular crystal in which krypton forms short covalent bonds with neighboring fluorine atoms thus adopting the +4 oxidation state. We find that this hitherto unknown compound can be stabilized at pressures below 50 GPa. Our results indicate also that, at larger compressions, a multitude of other KrmFn fluorides should be stable, among them KrF which exhibits covalent Kr–Kr bonds. Our results set the stage for future high-pressure synthesis of novel krypton compounds.

  20. An improved potential for krypton

    International Nuclear Information System (INIS)

    Aziz, R.A.

    1979-01-01

    An improved potential for krypton is presented. It has the simple but realistic form used by Aziz and Chen for argon based on the HFD potential suggested by Ahlrichs et.al. The potential, with known long-range behaviour, was fitted to second virial, viscosity and thermal conductivity data. The potential appears to have the best overall predictive ability for dilute gas, bulk and microscopic data. (author)

  1. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhkio

    1985-03-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images.

  2. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhiko.

    1985-01-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images. (author)

  3. Krypton isotope analysis using near-resonant stimulated Raman spectroscopy

    International Nuclear Information System (INIS)

    Whitehead, C.A.; Cannon, B.D.; Wacker, J.F.

    1994-12-01

    A method for measuring low relative abundances of 85 Kr in one liter or less samples of air has been under development here at Pacific Northwest Laboratory. The goal of the Krypton Isotope Laser Analysis (KILA) method is to measure ratios of 10 -10 or less of 85 Kr to more abundant stable krypton. Mass spectrometry and beta counting are the main competing technologies used in rare-gas trace analysis and are limited in application by such factors as sample size, counting times, and selectivity. The use of high-resolution lasers to probe hyperfine levels to determine isotopic abundance has received much attention recently. In this study, we report our progress on identifying and implementing techniques for trace 85 Kr analysis on small gas samples in a static cell as well as limitations on sensitivity and selectivity for the technique. High-resolution pulsed and cw lasers are employed in a laser-induced fluorescence technique that preserves the original sample. This technique, is based on resonant isotopic depletion spectroscopy (RIDS) in which one isotope is optically depleted while preserving the population of a less abundant isotope. The KILA method consists of three steps. In the first step, the 1s 5 metastable level of krypton is populated via radiative cascade following two-photon excitation of the 2p 6 energy level. Next, using RBDS, the stable krypton isotopes are optically depleted to the ground state through the 1s 4 level with the bulk of the 85 Kr population being preserved. Finally, the remaining metastable population is probed to determine 85 Kr concentration. The experimental requirements for each of these steps are outlined below

  4. Three-dimensional magnetic resonance coronary angiography using a new blood pool contrast agent : Initial experience

    NARCIS (Netherlands)

    Bedaux, WLF; Hofman, MBM; Wielopolski, PA; de Cock, CC; Hoffmann, [No Value; Oudkerk, M; de Feyter, PJ; van Rossum, AC

    2002-01-01

    Objective: The aim of this feasibility study was to assess the effect of a new blood pool contrast agent on magnetic resonance coronary angiography (MRCA) in patients suspected of having coronary artery disease. Methods: Nine patients referred for diagnostic x-ray coronary, angiography in the

  5. Use of sup(81m)Kr gas for the measurement of absolute regional lung ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Nosil, J; Bajzer, Z; Spaventi, S [Mladen Stojanovic Clinical Hospital, Zagreb (Yugoslavia). Dept. of Nuclear Medicine and Oncology; Institut Rudjer Boskovic, Zagreb (Yugoslavia))

    1977-02-01

    In this paper a new method of using sup(81m)Kr for the measurement of specific absolute regional lung ventilation is described. Experimental data suitable for the calculation of quantitative regional ventilation are provided using an adequate respiratory system for sup(81m)Kr dosage and a scintillation gamma camera interfaced to a digital computer. A simple mathematical lung model for the inhalation of sup(81m)Kr is used to determine the specific ventilation and the parameters proportional to the ventilation for the whole lung and different lung regions in patients and in healthy subjects. The lung count rate for a given region correlated well with the ventilation of that region. Clinical examples are given and discussed.

  6. Device for separating and concentrating rare gases containing krypton gas

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, S; Sugimoto, K

    1975-06-11

    In orer to highly concentrate krypton by means of adsorption and desorption of activated carbon, in a device for continuously separating and concentrating rare gases containing krypton gas by means of adsorbing and desorbing operation of activated carbon, the device includes adsorbers arranged in parallel and more than two stages of adsorbers arranged in series with the first mentioned adsorbers with the amount of activated carbon filled successively reduced, and a cooling mechanism for cooling the adsorbers when adsorbed and a heating mechanism for heating the adsorbers when desorbed.

  7. The effect of glucantime on the labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Holanda, Cecilia Maria Carvalho Xavier [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Centro de Biociencias. Dept. de Microbiologia e Parasitologia]. E-mail: cechol@ufrnet.br; Leite, Rodrigo Carvalho Holanda [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Curso Medico; Catanho, Maria Teresa Jansem; Souza, Grace Maria Lima [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia; Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Programa de Pos-Graduacao em Ciencias da Saude; Bernardo Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes; Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Programa de Pos-Graduacao em Ciencias da Saude

    2005-07-01

    Purpose: The labeling of red blood cells (C) with {sup 99m}Tc is employed in clinical nuclear medicine for a variety of diagnostic procedures. Drugs can alter this labeling method and modify the disposition of the radiopharmaceuticals. In this paper, the influence of glucan time on the labeling of blood constituents with {sup 99m}Tc was reported. Methods: Blood was withdrawn from rats and incubated with glucan time. Stannous chloride and {sup 99m}Tc were added. After centrifugation, plasma (P) and (C) were isolated. Samples of P and C were precipitated with TCA 5%, centrifuged and insoluble (IF) and soluble fractions (SF) separated. The percentages of total activity injected (%ATI) in C, IF-P and IF-C were calculated (p<0.05). Results: The %ATI on C decreased from control to following concentrations of glucan time (6.25%;12.5%;25%;50%;100%), respectively: 94.06{+-}1.29 (control) to 77.15{+-}2.79; to 76.68 {+-}1.88; to 75.15{+-}2.79; to 72.64{+-}4.40 and to 63.05{+-}3.84. On IF-C the %ATI decreased from control to all the concentrations of glucan time (3.125%;6.25%;12.5%;25%;50%; 100%), respectively: 93.34{+-}1.18 (control) to 78.81{+-}2.76; to 74.76{+-}4.82; to 74.02{+-}5.32; to 64.35{+-}4.82; to 62.81{+-}1.97 and to 54.55{+-}3.58. Conclusions: This effect was probably due to products present in this drug that may complex with ions (Sn{sup +2} and {sup 99m}TcO{sub 4}{sup -}) or have a direct or indirect effect on intracellular stannous ion concentration. (author)

  8. Experience gained in the cryodistillation unit for krypton removal

    International Nuclear Information System (INIS)

    Geens, L.; Collard, G.; Goossens, W.R.A.; Vaesen, P.J.

    1981-08-01

    This unit with a nominal gas throughput of 8.5 g.s -1 has been used to investigate the removal of krypton from reprocessing off-gases under non-radioactive conditions. During the investigation a total operation time of more than 13.000 hours was reached with an average availability factor of 99.36%. The trapping efficiency for krypton was higher than 99.9%. The operation experience acquired indicates some critical aspects for the design of such a unit. The experimental results obtained allow to show the influence of feed pressure and temperature, reflux flow rate and noble gas concentrations on the performance of the unit. (author)

  9. A review of the separation and immobilisation of krypton arising from nuclear fuel reprocessing plant

    International Nuclear Information System (INIS)

    Judd, S.J.

    1992-01-01

    The techniques for the separation and immobilisation of 85 Kr are reviewed. Particular attention is paid to processes currently available or undergoing development on the technical to industrial scale. Of the separation processes, cryogenic distillation has reached the most advanced stage of development, with a pilot facility already undergoing radioactive demonstration. The PNC Kr-recovery pilot plant, which has a off-gas flow capacity of 110 m 3 hr -1 (approximately 1/4 the scale of THORP), is currently undergoing tests at Tokai Mura. Low-temperature absorption and adsorption processes have also reached the pilot plant stage but have yet to undergo radiological tests. The separated krypton has been conventionally stored as the compressed gas in cylinders, but progress made in encapsulation techniques suggest that more secure immobilisation can be achieved by encapsulation within a metal or zeolite matrix. Processes based on the implantation of krypton in a metal or metal alloy have been demonstrated on the technical scale with the radioactive gas. It is concluded that the technology for the separation, isolation and immobilisation of radioactive krypton is available only on a reduced scale compared with THORP. The investment cost of a 85 Kr management facility for THORP, based on cryogenic distillation followed by immobilisation by implantation in metal and assuming a 20 year plant life, is estimated at 51-57M pounds. The cost of prepurification of the off-gas stream is included in this figure. Accompanying operating costs, including those incurred by disposal of the encapsulate in geological formations, are estimated at 2.2-3.3 M pounds per annum. Further development work under radioactive conditions is still required prior to the application of existing technology to full-scale fuel reprocessing plant. (author)

  10. Gated blood pool scintigraphy in patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Breuel, H.P.; Heusinger, J.H.; Hanisch, K.

    1984-10-01

    In 58 patients suffering from either stenosis or insufficiency of a single heart valve, gated blood pool scintigraphy was performed to determine the ejection fraction as well as the peak filling and peak ejection rates. It could be demonstrated that in patients with valvular disorders the ejection fraction was only moderately decreased, generally remaining in the lower reference range. The peak filling and ejection rates showed no pathologic changes with the exception of patients with aortic regurgitation where these rates were significantly decreased. Thus, the estimation of left ventricular peak filling and ejection rates may permit diagnosis of myocardial impairment in patients with valvular disease even under resting conditions.

  11. Krypton-85 hydrofracture engineering feasibility and safety evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Peretz, F.J.; Muller, M.E.; Pan, P.Y.

    1981-07-01

    Engineering studies have been made to determine the hazards associated with the disposal of /sup 85/Kr using the hydrofracture process. To assess the hazards, an effort has been made to identify the equipment required to entrain and dissolve the noble gas into the grout stream at hydrofracture pressure (up to 350 bar). Off-the-shelf or slightly modified equipment has been identified for safe and effective compression and gas-grout mixing. Each monthly injection disposes of 1.6 x 10/sup 6/ Ci of /sup 85/Kr. By connecting only one gas cylinder to the injection system at a time, the maximum amount of krypton likely to be released as a result of equipment failure is limited to 128,000 Ci. An evaluation by Los Alamos Technical Associates shows that releasing this amount of gas in less than one hour under worst-case meteorological conditions through a 30-m stack would result in a whole-body dose of 170 millirem at a distance of 1 km from the facility. A krypton collection and recovery system can further reduce this dose to 17 millirem; increasing the distance to the site boundary to 3 km can also reduce the dose by a factor of ten. Lung and skin dose estimates are 1.6 and 120 times the whole-body dose, respectively. These are all worst-case values; releases under more typical conditions would result in a significantly lower dose. No insurmountable safety or engineering problems have been identified.

  12. Krypton-85 hydrofracture engineering feasibility and safety evaluation

    International Nuclear Information System (INIS)

    Peretz, F.J.; Muller, M.E.; Pan, P.Y.

    1981-07-01

    Engineering studies have been made to determine the hazards associated with the disposal of 85 Kr using the hydrofracture process. To assess the hazards, an effort has been made to identify the equipment required to entrain and dissolve the noble gas into the grout stream at hydrofracture pressure (up to 350 bar). Off-the-shelf or slightly modified equipment has been identified for safe and effective compression and gas-grout mixing. Each monthly injection disposes of 1.6 x 10 6 Ci of 85 Kr. By connecting only one gas cylinder to the injection system at a time, the maximum amount of krypton likely to be released as a result of equipment failure is limited to 128,000 Ci. An evaluation by Los Alamos Technical Associates shows that releasing this amount of gas in less than one hour under worst-case meteorological conditions through a 30-m stack would result in a whole-body dose of 170 millirem at a distance of 1 km from the facility. A krypton collection and recovery system can further reduce this dose to 17 millirem; increasing the distance to the site boundary to 3 km can also reduce the dose by a factor of ten. Lung and skin dose estimates are 1.6 and 120 times the whole-body dose, respectively. These are all worst-case values; releases under more typical conditions would result in a significantly lower dose. No insurmountable safety or engineering problems have been identified

  13. Validation of Perfusion Quantification with 3D Gradient Echo Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Blood Pool Contrast Agent in Skeletal Swine Muscle.

    Directory of Open Access Journals (Sweden)

    Stefan Hindel

    Full Text Available The purpose of our study was to validate perfusion quantification in a low-perfused tissue by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI with shared k-space sampling using a blood pool contrast agent. Perfusion measurements were performed in a total of seven female pigs. An ultrasonic Doppler probe was attached to the right femoral artery to determine total flow in the hind leg musculature. The femoral artery was catheterized for continuous local administration of adenosine to increase blood flow up to four times the baseline level. Three different stable perfusion levels were induced. The MR protocol included a 3D gradient-echo sequence with a temporal resolution of approximately 1.5 seconds. Before each dynamic sequence, static MR images were acquired with flip angles of 5°, 10°, 20°, and 30°. Both static and dynamic images were used to generate relaxation rate and baseline magnetization maps with a flip angle method. 0.1 mL/kg body weight of blood pool contrast medium was injected via a central venous catheter at a flow rate of 5 mL/s. The right hind leg was segmented in 3D into medial, cranial, lateral, and pelvic thigh muscles, lower leg, bones, skin, and fat. The arterial input function (AIF was measured in the aorta. Perfusion of the different anatomic regions was calculated using a one- and a two-compartment model with delay- and dispersion-corrected AIFs. The F-test for model comparison was used to decide whether to use the results of the one- or two-compartment model fit. Total flow was calculated by integrating volume-weighted perfusion values over the whole measured region. The resulting values of delay, dispersion, blood volume, mean transit time, and flow were all in physiologically and physically reasonable ranges. In 107 of 160 ROIs, the blood signal was separated, using a two-compartment model, into a capillary and an arteriolar signal contribution, decided by the F-test. Overall flow in hind leg muscles

  14. A method for measurement of the krypton-85-content in the atmosphere

    International Nuclear Information System (INIS)

    Stockburger, H.; Sittkus, A.

    1975-01-01

    To measure the Kr-85 content in the atmosphere we developed a simple method. Within a time internal of five to ten days (depending on the moisture of the air) five to ten m 3 of air (NTP) are pumped through activated carbon (pressure 300 torr, temperature 77 K). When sampling time is over, the carbon is heated to 470 K. This gives a gas sample of 4 l with more than 90% of the atmospherical krypton in 3 hours. With a further step of enrichment, the volume of the sample is reduced to 100 ml. The final separation of krypton from O 2 , N 2 , CO, CO 2 and Xe is made by gaschromatography at room temperature with methane as eluent gas (duration 25 min). The Kr-fraction is transported to a proportional counter (200 ml). The overall yield is 90%. The overall error of the Kr-85-content is near 1%. Data are given for the time of 15.6.1973 to 29.12.1974. (orig.) [de

  15. Blood cell labeling with technetium-99m. II. Measurement of circulating blood volume by sup(99m)Tc-labeled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T; Yoshida, H; Matsuda, S; Kimura, H; Miura, N [Fukushima Medical Coll. (Japan)

    1978-02-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from /sup 51/Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 ..mu..Ci of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by /sup 51/Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by /sup 51/Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume.

  16. Estimation of reactor pool water temperature after shutdown in JRR-3M

    International Nuclear Information System (INIS)

    Yagi, Masahiro; Sato, Mitsugu; Kakefuda, Kazuhiro

    1999-01-01

    The reactor pool water temperature increasing by the decay heat was estimated by calculation. The reactor pool water temperature was calculated by increased enthalpy that was estimated by the reactor decay heat, the heat released from the reactor biological shielding concrete, reactor pool water surface, the heat conduction from the canal and the core inlet piping. These results of calculation were compared with the past measured data. As the results of estimation, after the JRR-3M shutdown, the calculated reactor pool temperature first increased sharply. This is because the decay heat was the major contribution. And then, rate of increased reactor pool temperature decreased. This is because the ratio of heat released from reactor biological shielding concrete and core inlet piping to the decay heat increased. Besides, the calculated reactor pool water temperature agreed with the past measured data in consequence of correcting the decay heat and the released heat. The corrected coefficient k 1 of decay heat was 0.74 - 0.80. And the corrected coefficient k 2 of heat released from the reactor biological shielding concrete was 3.5 - 4.5. (author)

  17. Environmental consequences of atmosphereic krypton-85. Final report, January 1, 1977-September 30, 1979

    International Nuclear Information System (INIS)

    Boeck, W.L.

    1979-01-01

    Krypton-85 is a radioactive inert gas produced during normal operations of the nuclear fuel cycle. The quantities of krypton-85, that will be produced in the next century, are sufficient, if released, to alter the electrical state of the atmosphere. The principal hypothesis is that an anthropogenic alteration of the electric state of the atmosphere could alter other meterological phenomena and lead to significant environmental impacts. The goal of this project was to explore some areas of basic science related to the evaluation of that hypothesis. The approach was primarily theoretical. The following topics were addressed: a first approximation model to estimate the effects of krypton-85 on the electrical state of the atmosphere; an analysis of the pathways between krypton-85 production and the atmosphere; an analytical model for fair weather atmospheric electricity; and a dipole model for atmospheric electricity. The results will provide a framework on which detailed models can be built. The results should provide better understanding of some topics in atmospheric electricity

  18. Clinical application of 99mTc-DTPA-HSA

    International Nuclear Information System (INIS)

    Kawamura, Yasuaki; Yamazaki, Junichi; Okuzumi, Ichio

    1989-01-01

    A newly developed blood pool imaging agent, Tc-99m DTPA-HSA (Tc-99m HSA-D), was clinically assessed in blood pool studies of patients with heart disease. Twenty mCi of Tc-99m HSA-D was iv injected to the patients. Similarly, conventional Tc-99m HSA was injected one week later for comparison. Blood counts of Tc-99m HSA-D were significantly higher than those of Tc-99m HSA at 30 minutes after iv injection (p<0.01) and at one, 3, and 6 hours (p<0.001). For the heart, liver, and lungs, sequential counts of Tc-99m HSA-D were also significantly higher than those of Tc-99m HSA. Free Tc-99m uptake in the stomach, thyroid gland, and kidneys was higher on Tc-99m HSA images than Tc-99m HSA-D images. Hepatic and pulmonary uptake of free Tc-99m that were visualized on Tc-99m HSA-D did not influence the diagnostic ability. None of the patients had clinical toxicity of Tc-99m HSA-D. The results indicate that Tc-99m HSA-D is a stable blood pool imaging agent. (Namekawa, K)

  19. Krypton-81 in groundwater of the Culebra Dolomite near the Waste Isolation Pilot Plant, New Mexico.

    Science.gov (United States)

    Sturchio, Neil C; Kuhlman, Kristopher L; Yokochi, Reika; Probst, Peter C; Jiang, Wei; Lu, Zheng-Tian; Mueller, Peter; Yang, Guo-Min

    2014-05-01

    The Waste Isolation Pilot Plant (WIPP) in New Mexico is the first geologic repository for disposal of transuranic nuclear waste from defense-related programs of the US Department of Energy. It is constructed within halite beds of the Permian-age Salado Formation. The Culebra Dolomite, confined within Rustler Formation evaporites overlying the Salado Formation, is a potential pathway for radionuclide transport from the repository to the accessible environment in the human-disturbed repository scenario. Although extensive subsurface characterization and numerical flow modeling of groundwater has been done in the vicinity of the WIPP, few studies have used natural isotopic tracers to validate the flow models and to better understand solute transport at this site. The advent of Atom-Trap Trace Analysis (ATTA) has enabled routine measurement of cosmogenic (81)Kr (half-life 229,000 yr), a near-ideal tracer for long-term groundwater transport. We measured (81)Kr in saline groundwater sampled from two Culebra Dolomite monitoring wells near the WIPP site, and compared (81)Kr model ages with reverse particle-tracking results of well-calibrated flow models. The (81)Kr model ages are ~130,000 and ~330,000 yr for high-transmissivity and low-transmissivity portions of the formation, respectively. Compared with flow model results which indicate a relatively young mean hydraulic age (~32,000 yr), the (81)Kr model ages imply substantial physical attenuation of conservative solutes in the Culebra Dolomite and provide limits on the effective diffusivity of contaminants into the confining aquitards. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Contribution to the study of the structure of silver krypton solid solutions

    International Nuclear Information System (INIS)

    Levy, V.; Tullairet, J.; Delaplace, J.; Antolin-Baudier, J.; Adda, Y.

    1964-01-01

    The silver-krypton solid solutions formed by electrical discharge have been studied by X-rays, electrical resistivity and electronic transmission microscopy. The crystalline parameter and residual resistivity measurements have shown that the krypton atom behaves very differently to those of other elements of the periodic classification when dissolved in silver. The recovery of the crystalline parameter and of the electrical resistivity has been studied as a function of temperature. (authors) [fr

  1. Neutron production with mixture of deuterium and krypton in Sahand Filippov type plasma focus facility

    International Nuclear Information System (INIS)

    Mohammadi, M.A.; Sobhanian, S.; Rawat, R.S.

    2011-01-01

    This Letter reports the order of magnitude enhancement in neutron yield from Sahand plasma focus device with krypton seeded deuterium operation. The highest average neutron yield of 2.2x10 9 neutrons per shot was achieved at 1.00 Torr deuterium with 3% krypton which is higher than the best average neutron yield of 3.18x10 8 neutrons per shot for pure deuterium operation. Estimation of average neutron energy showed that the maximum and minimum average energies are 2.98±0.6 MeV at 16 kV in 0.25 Torr deuterium with 3% Kr and 2.07±0.2 MeV at 18 kV operation in 0.5 Torr deuterium with 3% Kr, respectively. The anisotropy of neutron emission from Sahand DPF showed that the neutrons are produced mainly by beam-target mechanisms. -- Highlights: → The highest average neutron yield of 2.2x10 9 neutrons per shot was achieved at mixture of deuterium and krypton. → In the krypton seeding of deuterium also anisotropy of neutron emission deuterium is found. → The krypton seeding of deuterium made the neutron emission more reliable over wider operating pressure ranges.

  2. Application of Kr-81m gas for chronic obstructive pulmonary disease. A comparison of various inhalation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, K; Katsuyama, N i; Anno, I i; Harada, J; Kuroda, T [Jikei Univ., Tokyo (Japan). School of Medicine

    1978-11-01

    The Kr-81m ventilation study was performed by the following four inhalation techniques. 1) Spontaneous respiration with Kr-81m in air (Sp). 2) Serial inhalation of Kr-81m from residual volume to total lung capacity (VC). 3) Bolus inhalation of 50 ml of Kr-81m from the level of functional residual capacity (FRC), and 4) residual volume (RV), followed by air, to total lung capacity. Scintiphotos were taken during 10 sec of breathholding for VC, FRC, RV inhalation techniques and during tidal breathing for Sp technique, in a sitting position, by a scinticamera (Pho/Gamma HP). Twenty-three of the 28 subjects showed uneven distribution of the washout time in the Xe-133 study, 5 cases have a normal Xe-133 study. In severe obstructive changes with marked delay of the Xe-133 washout time, inhalation defects of Kr-81m were imaged in all techniques. In minor degrees of obstruction associated with slight delay of the washout, FRC and RV techniques detected abnormalities, whilst images by Sp and VC techniques showed homogeneous distribution of Kr-81m. This is due to rebreathing effect on Sp and to opening of partial airway obstruction in a high lung volume on VC technique. RV technique had a disadvantage for imaging of abnormalities in the lower lung fields, because Kr-81m concentration is low in the lower lung fields, due to physiological closure of the small airway. In 3 of 5 cases of asymptomatic asthma with a normal Xe-133 study, uneven distribution in RV technique was the only abnormality detected. FRC technique was most sensitive for slight obstructive changes in the upper lung fields as well as in the lower. For the ventilation study using Kr-81m, a combined test of Sp, VC, RV and FRC inhalation techniques is useful for early detection of the small airway disease and evaluation of the degree of abnormalities.

  3. Transscleral contact krypton laser cyclophotocoagulation for treatment of posttraumatic glaucoma.

    Science.gov (United States)

    Raivio, V E; Immonen, I J; Laatikainen, L T; Puska, P M

    2001-04-01

    To evaluate the usefulness of the krypton laser for transscleral contact cyclophotocoagulation in the treatment of posttraumatic glaucoma. A total of 18 eyes of 18 patients with therapy-resistant posttraumatic glaucoma treated with krypton laser cyclophotocoagulation from 1991 to 1996 were included in this review. The krypton laser was delivered by a fiberoptic probe with simultaneous compression of the sclera. The energy used was 3 to 5 J per application at the tip of the probe, with an exposure time of 10 seconds. The treatment covered 90 to 360 degrees of the ciliary body with approximately 10 applications per quadrant. With one or more cyclophotocoagulation treatments, the intraocular pressure decreased from the baseline mean (+/- standard deviation) of 32.6 +/- 12.8 mm Hg to 23.6 +/- 10.3 mm Hg (n = 17) at 1 month, to 21.8 +/- 7.5 mm Hg (n = 13) at 3 months, to 22.5 +/- 7.6 mm Hg (n = 13) at 6 months, and to 19.6 +/- 10.5 mm Hg (n = 18) at the last control visit (mean, 19.4 months; range, 3 weeks to 73 months) after cyclophotocoagulation but no other glaucoma procedure. At baseline, 17 (94%) of 18 patients were taking glaucoma medication, as were 15 (83%) of 18 patients at the last control visit. One (6%) case of phthisis occurred. Krypton laser cyclophotocoagulation is an effective and reasonably well tolerated means of lowering intraocular pressure in posttraumatic glaucoma. Because of the refractory nature of the disease, repeated treatments may be needed.

  4. Proposta do uso de pool de sangue total como controle interno de qualidade em hematologia Proposal for the use of a pool of whole blood as internal quality control in hematology

    Directory of Open Access Journals (Sweden)

    Carina Daniele Schons

    2010-06-01

    Full Text Available INTRODUÇÃO: A confiabilidade dos resultados do laboratório é garantida pela realização do controle de qualidade, que tem como funções básicas análise, pesquisa e prevenção da ocorrência de erros laboratoriais por meio de programas que abrangem tanto o controle interno quanto o externo. OBJETIVO: Propor a padronização de utilização de pool de sangue total como controle interno de qualidade no setor de hematologia. MÉTODO: Foram selecionadas amostras de sangue total, colhidas com ácido etilenodiaminotetracético (EDTA, de mesmos grupo sanguíneo e fator Rh, livres de interferentes, como hemólise, lipemia e icterícia. De um total de 30 ml de sangue total, obtiveram-se três alíquotas de 10 ml cada, às quais foram adicionados, respectivamente, 0 ml (sem adição, 1 ml e 5 ml de glicerol (conservante. As amostras foram avaliadas em contador automático ADVIA® 60. Após determinação dos valores de média e DP, todas as amostras foram avaliadas por um período de 45 dias úteis para confecção do gráfico de Levey-Jennings e verificação da estabilidade da amostra. RESULTADO E CONCLUSÃO: Podemos verificar que o pool de sangue total, preparado de acordo com a metodologia proposta, não apresenta estabilidade necessária para sua utilização, como controle interno alternativo no setor de hematologia.INTRODUCTION: The reliability of laboratory results is ensured by the implementation of quality control, which has basic functions, such as analysis, research and prevention of laboratory errors through programs that encompass both internal and external control. OBJECTIVE: To propose a standard method to use pooled whole blood as internal quality control in the Hematology division. METHOD: The selected whole blood samples were collected with EDTA, belonged to the same blood group and Rh factor and did not present interfering factors, such as hemolysis, lipemia and icterus. From a total of 30 ml of whole blood it was obtained 3

  5. The gated blood pool scan in the evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Anger, K.; Erbel, R.; Krebs, W.; Meyer, J.; Moeller, T.; Schweizer, P.; Yalkinoglu, O.; Technische Hochschule Aachen

    1983-01-01

    38 patients with clinically suspected coronary artery disease were studied by contrast ventriculography, 2-dimensional echocardiography and multiple gated blood pool imaging (MUGA) without stress. The results were compared with eath other and with the final diagnosis confirmed by coronary angiography. The left ventricular ejection fraction is evaluated nearly identically and with sufficient accuracy by both non-invasive methods, local motion abnormalities are on the other hand diagnosed in the best way by MUGA imaging in our own cases. (orig.) [de

  6. Feasibility of Single Scan for Simultaneous Evaluation of Regional Krypton and Iodine Concentrations with Dual-Energy CT: An Experimental Study.

    Science.gov (United States)

    Hong, Sae Rom; Chang, Suyon; Im, Dong Jin; Suh, Young Joo; Hong, Yoo Jin; Hur, Jin; Kim, Young Jin; Choi, Byoung Wook; Lee, Hye-Jeong

    2016-11-01

    Purpose To evaluate the feasibility of a simultaneous single scan of regional krypton and iodine concentrations by using dual-energy computed tomography (CT). Materials and Methods The study was approved by the institutional animal experimental committee. An airway obstruction model was first made in 10 beagle dogs, and a pulmonary arterial occlusion was induced in each animal after 1 week. For each model, three sessions of dual-energy CT (80% krypton ventilation [krypton CT], 80% krypton ventilation with iodine enhancement [mixed-contrast agent CT], and iodine enhancement [iodine CT]) were performed. Krypton maps were made from krypton and mixed-contrast agent CT, and iodine maps were made from iodine and mixed-contrast agent CT. Observers measured overlay Hounsfield units of the diseased and contralateral segments on each map. Values were compared by using the Wilcoxon signed-rank test. Results In krypton maps of airway obstruction, overlay Hounsfield units of diseased segments were significantly decreased compared with those of contralateral segments in both krypton and mixed-contrast agent CT (P = .005 for both). However, the values of mixed-contrast agent CT were significantly higher than those of krypton CT for both segments (P = .005 and .007, respectively). In iodine maps of pulmonary arterial occlusion, values were significantly lower in diseased segments than in contralateral segments for both iodine and mixed-contrast agent CT (P = .005 for both), without significant difference between iodine and mixed-contrast agent CT for both segments (P = .126 and .307, respectively). Conclusion Although some limitations may exist, it might be feasible to analyze regional krypton and iodine concentrations simultaneously by using dual-energy CT. © RSNA, 2016.

  7. Krypton-85 and other airborne radioactivity measurements throughout Ireland

    International Nuclear Information System (INIS)

    Smith, K.J.; Murray, M.; Wong, J.; Sequeira, S.; Long, S.C.; Rafferty, B.

    2004-01-01

    In compliance with articles 35 and 36 of the EURATOM Treaty, the Radiological Protection Institute of Ireland (RPII) undertakes a comprehensive programme of radioactivity monitoring in the Irish terrestrial environment. Radioactivity is present in the terrestrial environment due to natural processes, the testing of nuclear weapons in the atmosphere, accidents such as the Chernobyl accident and the routine discharge of radionuclides from nuclear installations. The RPII monitors airborne radioactivity concentrations at ten stations throughout Ireland, of which, nine are equipped with low volume particulate samplers and one, in Dublin, with a high volume particulate sampler. The low volume particulate samples are assessed for total beta activity and high volume samples for gamma emitting radionuclides such as caesium-137 and beryllium-7. In addition, air sampled at the RPII laboratory in Dublin, is monitored for krypton-85, a radioactive noble gas, released into the environment primarily as a result of the reprocessing of nuclear fuel at installations such as Sellafield in the UK and La Hague in France. Since the inception of the krypton measurements in 1993 a trend of increasing atmospheric concentrations has been observed. The results of the krypton-85 monitoring, as well as the airborne radioactivity concentration measurements, will be presented and discussed in this paper. (author)

  8. Gated blood pool study in one case of endocarditis parietalis fibroplastica LOEFFLER - a case report

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H; Mahlstedt, J; Wolf, F

    1983-10-01

    The rare case of endocarditis parietalis fibroplastica Loeffler is described. In laevocardiography this kind of endomyocardfibrose, in our patient combined with excessive blood eosinophilia of 86%, presents a typical diastolic-systolic contraction pattern. Gated blood pool study matches well with the results of contrast angiography. Exercise-testing provoked an EF increase of from 48% to 55%, excluding CAD. Clinical complaints are not specific, caused by extreme restriction of myocardial compliance with high left ventricular filling pressure and subsequent mean pulmonary hypertonus. The patient died before the operative intervention in sudden heart death.

  9. Gated blood pool study in one case of endocarditis parietalis fibroplastica LOEFFLER - a case report

    International Nuclear Information System (INIS)

    Feistel, H.; Mahlstedt, J.; Wolf, F.

    1983-01-01

    The rare case of endocarditis parietalis fibroplastica Loeffler is described. In laevocardiography this kind of endomyocardfibrose, in our patient combined with excessive blood eosinophilia of 86%, presents a typical diastolic-systolic kontraction pattern. Gated blood pool study matches well with the results of contrast angiography. Exercise-testing provoked an EF increase of from 48% to 55%, excluding CAD. Clinical complaints are not specific, caused by extreme restriction of myocardial compliance with high left ventricular filling pressure and subsequent mean pulmonary hypertonus. The patient died before the operative intervention in sudden heart death. (orig.) [de

  10. Assessing the performance of multiplexed tandem PCR for the diagnosis of pathogenic genotypes of Theileria orientalis using pooled blood samples from cattle.

    Science.gov (United States)

    Gebrekidan, Hagos; Gasser, Robin B; Stevenson, Mark A; McGrath, Sean; Jabbar, Abdul

    2017-02-01

    Oriental theileriosis caused by multiple genotypes of Theileria orientalis is an important tick-borne disease of bovines. Here, we assessed the performance of an established multiplexed tandem PCR (MT-PCR) for the diagnosis of the two recognized, pathogenic genotypes (chitose and ikeda) of T. orientalis in cattle using pooled blood samples. We used a total of 265 cattle blood samples, which were divided into two groups according to previous MT-PCR results for individual samples. Samples in group 1 (n = 155) were from a herd with a relatively high prevalence of T. orientalis infection; and those in group 2 (n = 110) were from four herds with a low prevalence. For group 1, 31 and 15 batches of five- and ten-pooled samples (selected at random), respectively, were formed. For group 2, 22 and 11 batches of five- and ten-pooled samples (selected at random), respectively, were formed. DNAs from individual pooled samples in each batch and group were then tested by MT-PCR. For group 1, the apparent prevalences estimated using the 31 batches of five-pooled samples (97%) and 15 batches of ten-pooled samples (100%) were significantly higher compared with individual samples (75%). For group 2, higher apparent prevalences (9% and 36%) were also recorded for the 22 and 11 batches of pooled samples, respectively, compared with individual samples (7%). Overall, the average infection intensity recorded for the genotypes of chitose and ikeda were considerably lower in pooled compared with individual samples. The diagnostic specificities of MT-PCR were estimated at 95% and 94%, respectively, when batches of five- and ten-pooled samples were tested, and 94% for individual samples. The diagnostic sensitivity of this assay was estimated at 98% same for all individual, five- and ten-pooled samples. This study shows that screening batches of five- and ten-pooled blood samples from cattle herds are similar to those obtained for individual samples, and, importantly, that the reduced cost

  11. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  12. The NA62 Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger

    CERN Document Server

    INSPIRE-00293812; Paoluzzi, Giovanni; Salamon, Andrea; Salina, Gaetano; Santovetti, Emanuele; Scarfi, Francesco M.; Bonaiuto, Vincenzo; Sargeni, Fausto

    2012-01-01

    The NA62 experiment at CERN SPS aims to measure the Branching Ratio of the very rare kaon decay K+ -> pi+ nu nubar collecting O(100) events with a 10% background to make a stringent test of the Standard Model. One of the main backgrounds to the proposed measurement is represented by the K+ -> pi+ pi0 decay. To suppress this background an efficient photo veto system is foreseen. In the 1-10 mrad angular region the NA48 high performance liquid krypton electromagnetic calorimeter is used. The design, implementation and current status of the Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger are presented.

  13. The NA62 Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger

    CERN Document Server

    INSPIRE-00646848; Fucci, Adolfo; Paoluzzi, Giovanni; Salamon, Andrea; Salina, Gaetano; Santovetti, Emanuele; Scarfi, Francesco M.; Sargeni, Fausto

    2011-01-01

    The NA62 experiment at CERN SPS aims to measure the Branching Ratio of the very rare kaon decay K+ -> pi+ nu nubar collecting O(100) events with a 10% background to make a stringent test of the Standard Model. One of the main backgrounds to the proposed measurement is represented by the K+ -> pi+ pi0 decay. To suppress this background an efficient photo veto system is foreseen. In the 1-10 mrad angular region the NA48 high performance liquid krypton electromagnetic calorimeter is used. The design, implementation and current status of the Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger are presented.

  14. Multiaxial tomography of heart chambers by gated blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Tamaki, N.; Mukai, T.; Ishii, Y.; Yonekura, Y.; Yamamoto, K.; Kadota, K.; Kambara, H.; Kawai, C.; Torizuka, K.

    1983-01-01

    Fifteen patients and three volunteers underwent radionuclide blood-pool cardiac studies with electrocardiographic gating. Following conventional planar-gated imaging (anterior and left anterior oblique projections), emission computed tomography (ECT), using a rotating gamma camera, was performed.A series of transaxial tomograms of the cardiac chambers was obtained. The left ventricular short-axis plane, long-axis plane, and four-chamber-view plane were then reorganized; each chamber was visualized separately. Compared to gated planar imaging, this technique showed regional asynergy more clearly in patients with myocardial infarction and demonstrated dilatation of the atria and ventricles more accurately in patients with an atrial septal defect and valvular heart diseases. In addition, when a section of the heart is otained at any angle with gated blood pool ECT, three-dimensional assessment of cardiac chambers in motion is more precise; mutual superimposition becomes unnecessary

  15. Separation of the fission product noble gases krypton and xenon from dissolver off-gas in reprocessing HTGR-fuel

    Energy Technology Data Exchange (ETDEWEB)

    Bohnenstingl, J.; Djoa, S. H.; Laser, M.; Mastera, S.; Merz, E.; Morschl, P.

    1976-04-15

    This paper describes a process developed for the retainment and separation of volatile (3H, 129 +131I) and gaseous (85Kr, Xe) fission products from the off-gas produced during dissolution of HTGR-fuel. To prevent unnecessary dilution of liberated noble gases by surrounding atmosphere, a helium purge-gas cycle is applied to enable a coarse fractionating of krypton and xenon by cold-trapping at about 80 deg K after precleaning the gas stream. The process consists of the following steps: deposition of droplets and solid aerosols; chemisorption of iodine on silver impregnated silica gel; catalytic removal of nitrogen oxides and oxygen; drying of the process gas stream; final filtering of abraded solids; deposition of xenon in solid form at 80 deg K and low subpressure; deposition of krypton in solid form at 80 deg K after compression to about 6 bar; decontamination of 85krypton-containing xenon by batch distillation for eventual industrial utilization; and removal of nitrogen and argon enrichment during continuous operation in the purge-gas stream by inleaking air with charcoal. A continuously operating dissolver vessel, closed to the surrounding atmosphere, yields a very high content of noble gases, e.g., 0.35 vol % krypton and 2.0 vol % xenon. The presented off-gas treatment unit is operated in cold runs with 1/3 of the full capacity and can treat about 1 m3 STP/h helium, corresponding to a quantity of about 10,000 MW(e) HTGR-fuel reprocessing plant.

  16. Cardiac cine MRI: Comparison of 1.5 T, non-enhanced 3.0 T and blood pool enhanced 3.0 T imaging

    International Nuclear Information System (INIS)

    Gerretsen, S.C.; Versluis, B.; Bekkers, S.C.A.M.; Leiner, T.

    2008-01-01

    Introduction: Cardiac cine imaging using balanced steady state free precession sequences (bSSFP) suffers from artefacts at 3.0 T. We compared bSSFP cardiac cine imaging at 1.5 T with gradient echo imaging at 3.0 T with and without a blood pool contrast agent. Materials and methods: Eleven patients referred for cardiac cine imaging underwent imaging at 1.5 T and 3.0 T. At 3.0 T images were acquired before and after administration of 0.03 mmol/kg gadofosveset. Blood pool signal-to-noise ratio (SNR), temporal variations in SNR, ejection fraction and myocardial mass were compared. Subjective image quality was scored on a four-point scale. Results: Blood pool SNR increased with more than 75% at 3.0 T compared to 1.5 T (p < 0.001); after contrast administration at 3.0 T SNR increased with 139% (p < 0.001). However, variations in blood pool SNR at 3.0 T were nearly three times as high versus those at 1.5 T in the absence of contrast medium (p < 0.001); after contrast administration this was reduced to approximately a factor 1.4 (p = 0.21). Saturation artefacts led to significant overestimation of ejection fraction in the absence of contrast administration (1.5 T: 44.7 ± 3.1 vs. 3.0 T: 50.7 ± 4.2 [p = 0.04] vs. 3.0 T post contrast: 43.4 ± 2.9 [p = 0.55]). Subjective image quality was highest for 1.5 T (2.8 ± 0.3), and lowest for non-enhanced 3.0 T (1.7 ± 0.6; p = 0.006). Conclusions: GRE cardiac cine imaging at 3.0 T after injection of the blood pool agent gadofosveset leads to improved objective and subjective cardiac cine image quality at 3.0 T and to the same conclusions regarding cardiac ejection fraction compared to bSSFP imaging at 1.5 T

  17. Evaluation of latent cardiac disease in diabetic patients with Tl-201 exercise myocardial scintigram and blood pool scintigram

    International Nuclear Information System (INIS)

    Miyashita, Takeo; Kasai, Ryutaro; Ikebe, Nobuhiko; Nagai, Yoshikazu; Yamasawa, Ikuhiro; Ibukiyama, Chiharu; Notoya, Yoko

    1990-01-01

    To find latent heart disease in diabetic patients, 142 diabetic patients were divided into 4 groups: (1) no hypertension and normal ECG (DM group); (2) hypertension recognized clinically (HT group); (3) myocardial damage on ECG (MD group); (4) group associated with the previous 2 (HT+MD group). In all groups Tl-201 exercise myocardial scintigrams and blood pool scintigrams were taken for comparative analysis. Positive rates of SPECT were 27.7% (23/83) in the DM group, 30.0% (9/30) in the HT group, 50.0% (6/12) in the MD group, and 70.6% (12/17) in the HT+MD group. The rate in the HT+MD group was significantly higher than in that of the DM and HT groups (p<0.001, p<0.01). Blood pool scintigrams revealed that in the HT+MD group, as compared with the normal control group, both 1/3 FF and PFR were significantly depressed, in addition to significant TPF prolongation in the former (p<0.001, p<0.05, p<0.05). These findings suggest that in diabetic patients hypertension and myocardial damage would lead to a high incidence of abnormality in SPECT and left ventricular rapid filling dysfunction. This indicate a high incidence of latent cardiac disease which can be recognized in diabetic patients by stress myocardial and blood pool scintigrams. (author)

  18. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. II

    International Nuclear Information System (INIS)

    Harangozo, M.; Jombik, J.; Schiller, P.; Toelgyessy, J.

    1981-01-01

    A method for the determination of citric, tartaric and undecylenic acids based on radiometric titration with 0.1 or 0.05 mole.l -1 NaOH was developed. As an indicator of the end point, radioactive kryptonate of glass was used. Experimental technique, results of determinations as well as other possible applications of the radioactive kryptonate of glass for end point determination in alkalimetric analyses of officinal pharmaceuticals are discussed. (author)

  19. Differential cellular recognition pattern to M. tuberculosis targets defined by IFN-γ and IL-17 production in blood from TB + patients from Honduras as compared to health care workers: TB and immune responses in patients from Honduras.

    Science.gov (United States)

    Alvarez-Corrales, Nancy; Ahmed, Raija K; Rodriguez, Carol A; Balaji, Kithiganahalli N; Rivera, Rebeca; Sompallae, Ramakrishna; Vudattu, Nalini K; Hoffner, Sven E; Zumla, Alimuddin; Pineda-Garcia, Lelany; Maeurer, Markus

    2013-03-06

    A better understanding of the quality of cellular immune responses directed against molecularly defined targets will guide the development of TB diagnostics and identification of molecularly defined, clinically relevant M.tb vaccine candidates. Recombinant proteins (n = 8) and peptide pools (n = 14) from M. tuberculosis (M.tb) targets were used to compare cellular immune responses defined by IFN-γ and IL-17 production using a Whole Blood Assay (WBA) in a cohort of 148 individuals, i.e. patients with TB + (n = 38), TB- individuals with other pulmonary diseases (n = 81) and individuals exposed to TB without evidence of clinical TB (health care workers, n = 29). M.tb antigens Rv2958c (glycosyltransferase), Rv2962c (mycolyltransferase), Rv1886c (Ag85B), Rv3804c (Ag85A), and the PPE family member Rv3347c were frequently recognized, defined by IFN-γ production, in blood from healthy individuals exposed to M.tb (health care workers). A different recognition pattern was found for IL-17 production in blood from M.tb exposed individuals responding to TB10.4 (Rv0288), Ag85B (Rv1886c) and the PPE family members Rv0978c and Rv1917c. The pattern of immune target recognition is different in regard to IFN-γ and IL-17 production to defined molecular M.tb targets in PBMCs from individuals frequently exposed to M.tb. The data represent the first mapping of cellular immune responses against M.tb targets in TB patients from Honduras.

  20. Detecting early cardiac dysfunction with radionuclide cardiac blood-pool imaging

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Lin Haoxue

    1992-01-01

    Cardiac function was measured by radionuclide cardiac blood-pool imaging in 15 normal persons, 19 cases of hypertension, 32 cases of coronary heart disease, 35 cases of coronary heart disease combined with hypertension and 44 cases of myocardial infarction. Significant differences have been found in indices of cardiac function between normal subjects and patients with coronary heart disease and coronary heart disease combined with hypertension, even though the patients were without any clinical sin of cardiac failure. Lowered regional EF and decreased ventricular was motion were found in 38.8% of patients, while 65.7%of patients revealed marked abnormality in MFR. The results indicate that latent cardiac dysfunction is common in patients with coronary heart disease. The earliest change is diastolic function abnormalities

  1. The mutual influence of krypton implantation and pre-existing stress states in polycrystalline alpha titanium

    Energy Technology Data Exchange (ETDEWEB)

    Nsengiyumva, S. [Department of Physics, University of Cape Town, Rondebosch 7701 (South Africa); Department of Physics, Kigali Institute of Education, P.O. Box 5039 Kigali (Rwanda)], E-mail: schadrack.nsengiyumva@uct.ac.za; Ntsoane, T.P. [Nuclear Energy Corporation of South Africa (NECSA), P.O. Box 582 (South Africa); Raji, A.T. [Department of Physics, University of Cape Town, Rondebosch 7701 (South Africa); Topic, M. [iThemba LABS, Somerset West 7129 (South Africa); Kellermann, G. [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas (Brazil); Riviere, J.P. [Laboratoire de Physique des Materiaux UMR6630-CNRS, 86960 (France); Britton, D.T.; Haerting, M. [Department of Physics, University of Cape Town, Rondebosch 7701 (South Africa)

    2009-08-15

    The stress profile in polycrystalline titanium implanted with krypton ions at different fluences has been determined using synchrotron radiation diffraction. For each fluence, the krypton profile has been measured using Rutherford backscattering geometry. The results were compared to model calculations obtained from the SRIM 2008 computer code. A strong stress relaxation was found for high fluence implantation, whereas for low fluence implantation an additional source of tensile stress was introduced in the near surface region. The projected range of the implanted krypton was significantly reduced compared to the expected range. A possible cause of this discrepancy is the drift of implanted ions under the influence of the pre-existing stress gradient.

  2. The mutual influence of krypton implantation and pre-existing stress states in polycrystalline alpha titanium

    International Nuclear Information System (INIS)

    Nsengiyumva, S.; Ntsoane, T.P.; Raji, A.T.; Topic, M.; Kellermann, G.; Riviere, J.P.; Britton, D.T.; Haerting, M.

    2009-01-01

    The stress profile in polycrystalline titanium implanted with krypton ions at different fluences has been determined using synchrotron radiation diffraction. For each fluence, the krypton profile has been measured using Rutherford backscattering geometry. The results were compared to model calculations obtained from the SRIM 2008 computer code. A strong stress relaxation was found for high fluence implantation, whereas for low fluence implantation an additional source of tensile stress was introduced in the near surface region. The projected range of the implanted krypton was significantly reduced compared to the expected range. A possible cause of this discrepancy is the drift of implanted ions under the influence of the pre-existing stress gradient.

  3. Bonding xenon and krypton on the surface of uranium dioxide single crystal

    Directory of Open Access Journals (Sweden)

    Dąbrowski Ludwik

    2014-08-01

    Full Text Available We present density functional theory (DFT calculation results of krypton and xenon atoms interaction on the surface of uranium dioxide single crystal. A pseudo-potential approach in the generalised gradient approximation (GGA was applied using the ABINIT program package. To compute the unit cell parameters, the 25 atom super-cell was chosen. It has been revealed that close to the surface of a potential well is formed for xenon and krypton atom due to its interaction with the atoms of oxygen and uranium. Depth and shape of the well is the subject of ab initio calculations in adiabatic approximation. The calculations were performed both for the case of oxygenic and metallic surfaces. It has been shown that the potential well for the oxygenic surface is deeper than for the metallic surface. The thermal stability of immobilising the atoms of krypton and xenon in the potential wells were evaluated. The results are shown in graphs.

  4. Simulations of Atmospheric Krypton-85 to Assess the Detectability of Clandestine Nuclear Reprocessing

    International Nuclear Information System (INIS)

    Ross, O.; Ahlswede, J.; Annewandter, R.; Kalinowski, M.B.; Rast, S.; Schluenzen, K.H.

    2010-01-01

    The results of this study were achieved in the project 'Simulation of Atmospheric Noble Gas Concentrations to Assess Sampling Procedures for the Detection of Clandestine Nuclear Reprocessing' (IAEA GER 1643) in the joint programme of IAEA and Federal Government of Germany. In the first year of the project the detectability of additional krypton-85 sources was investigated using atmospheric transport modelling. Krypton-85 is released into the air during reprocessing of spent nuclear fuel rods. Therefore the krypton-85 signature can possibly be used for the detection of undeclared plutonium separation. First, the global krypton-85 background produced by known reprocessing facilities from 1971 until 2006 was simulated with the atmospheric general circulation model ECHAM5 using annual emission data. The model results were evaluated by extensive comparison with measurements performed by the German Federal Office for Radiation Protection. Of particular interest for an assessment of the detectability of unknown sources is the background variability. The variability of concentrations is very high over central Europe, where the large reprocessing plants La Hague and Sellafield are located, and it is very low on the Southern Hemisphere, where no nuclear reprocessing takes place. The analysis of concentration time series on various time scales allows partly a distinction between fluctuations caused by the variability of the sources from variations due to atmospheric dynamics. Furthermore the detection sensitivity to a set of arbitrarily specified source locations is analysed with a Lagrangian particle dispersion model. This, in combination with the location specific background variability, is giving first benchmarks on the capability of using krypton-85 for IAEA Safeguards based on the Additional Protocols foreseeing environmental sampling. (author)

  5. Immobilisation of krypton in a metallic matrix by combined ion implantation and sputtering

    International Nuclear Information System (INIS)

    Whitmell, D.S.

    1980-01-01

    With the increase in nuclear power, it may be necessary to contain for 100 to 200 years the radioactive 85 krypton released during fuel reprocessing. The ideal method of immobilising radioactive materials is in the form of stable, monolithic solids which are resistant to the effects of the environment or accidents, and which can retain the radioactivity under all envisaged conditions. Since krypton is a rare gas, not forming thermally stable compounds, conventional methods of storage are not possible. A process is being developed to immobilise the krypton in the form of small gas bubbles in a metal matrix by implanting the gas into a metal layer from a glow discharge and then burying the implanted layer by sputter deposition. By repeating the process, a thick layer of deposit is built up with the krypton dispersed throughout the matrix as bubbles of diameter less than 20 A. This process offers an ideal form of storage since gas in bubbles is not thermally released until the temperature of the matrix is close to the melting point, and also leakage of gas by corrosion or mechanical damage will be small. A pilot plant is being built in order to demonstrate the process on a scale comparable with that required for a reprocessing plant. The efficiency of the process is dependent upon the amount of gas which can be implanted at low energy into a thin layer and its subsequent retention. More information is required on the processes occurring when krypton ions are implanted close to the surface, in particular, the retention and re-emission of the gas, and the formation of clusters and bubbles. (author)

  6. Krypton-81, Helium-4 and Carbon-14 based estimation of groundwater ages in the Guarani Aquifer System: implications for the He-4 geochronometer

    Science.gov (United States)

    Aggarwal, P. K.; Chang, H. K.; Gastmans, D.; Sturchio, N. C.; Araguas, L.; Matsumoto, T.; Lu, Z.; Jiang, W.; Yokochi, R.; Mueller, P.

    2012-12-01

    Characterization of aquifer systems remains a challenge, particularly for large aquifers with limited hydrogeological information. Groundwater age is an important parameter that integrates aquifer recharge and flow dynamics and provides the ability to reliably constrain groundwater models. We have used multiple isotope tracers (C-14, He-4, and Kr-81) to estimate the age of groundwater along a 400-km transect in the north-eastern part of the Guarani Aquifer System (GAS) in Brazil. Carbon-14 measurements were made with an AMS, He-4 by mass-spectrometry, and Kr-81 by atom trap trace analysis (ATTA). Groundwater samples were collected along a groundwater flow path that runs from the outcrop area in the east to the deep confined section in the west, where the aquifer is up to about 1000 m deep. Present groundwater recharge occurs in the outcrop areas, as indicated by the presence of tritium and modern 14C. Carbon-14 activities reach values below detection limit at relatively short distances (a few km) from the outcrop. Abundance of 81Kr (half-life 229 Ka), in samples free of C-14, decreases from 0.81±0.11 (expressed as (81Kr/Kr)sample/(81Kr/Kr)air) in the east to 0.18±0.03 in the western-most sample (estimated age = 566±60 ka). Measured 4He-excess is far above that expected from in-situ production rates in sandstone aquifers and overestimates the age by several orders of magnitude. We used 81Kr ages to calibrate the 4He geochronometer which indicates a basal flux of about 2.8 x10-11 cm3STP He/cm2/a. This flux is lower than most estimates of basal flux in previous studies and will allow a wider use of 4He for groundwater dating and aquifer characterization.

  7. Clinical validation of fully automated computation of ejection fraction from gated equilibrium blood-pool scintigrams

    International Nuclear Information System (INIS)

    Reiber, J.H.C.; Lie, S.P.; Simoons, M.L.; Hoek, C.; Gerbrands, J.J.; Wijns, W.; Bakker, W.H.; Kooij, P.P.M.

    1983-01-01

    A fully automated procedure for the computation of left-ventricular ejection fraction (EF) from cardiac-gated Tc-99m blood-pool (GBP) scintigrams with fixed, dual, and variable ROI methods is described. By comparison with EF data from contrast ventriculography in 68 patients, the dual-ROI method (separate end-diastolic and end-systolic contours) was found to be the method of choice; processing time was 2 min. Success score of dual-ROI procedure was 92% as assessed from 100 GBP studies. Overall reproducibility of data acquisition and analysis was determined in 12 patients. Mean value and standard deviation of differences between repeat studies (average time interval 27 min) were 0.8% and 4.3% EF units, respectively, (r=0.98). The authors conclude that left-ventricular EF can be computed automatically from GBP scintigrams with minimal operator-interaction and good reproducibility; EFs are similar to those from contrast ventriculography

  8. Half a decade of mini-pool nucleic acid testing: Cost-effective way for improving blood safety in India

    Directory of Open Access Journals (Sweden)

    Shivaram Chandrashekar

    2014-01-01

    Full Text Available Background and Objectives: It is well established that Nucleic acid testing (NAT reduces window phase of transfusion transmissible infections (TTI and helps improve blood safety. NAT testing can be done individually or in pools. The objectives of this study were to determine the utility, feasibility and cost effectiveness of an in-house minipool-NAT(MP-NAT. Materials and Methods: Blood donors were screened by history, tested by ELISA and sero-negative samples were subjected to an in-house NAT by using reverse transcriptase-polymerase chain reaction (RT-PCR. Testing was done in mini-pools of size eight (8. Positive pools were repeated with individual samples. Results: During the study period of Oct 2005-Sept 2010 (5 years all blood donors (n=53729 were screened by ELISA. Of which 469 (0.87% were positive for HIV-1, HBV or HCV. Sero-negative samples (n=53260 were screened by in-house MP-NAT. HIV-NAT yield was 1/53260 (n=1 and HBV NAT yield (n=2 was 1/26630. Conclusion: NAT yield was lower than other India studies possibly due to the lower sero-reactivity amongst our donors. Nevertheless it intercepted 9 lives including the components prepared. The in-house assay met our objective of improving blood safety at nominal cost and showed that it is feasible to set up small molecular biology units in medium-large sized blood banks and deliver blood within 24-48 hours. The utility of NAT (NAT yield will vary based on the donor population, the type of serological test used, the nature of kit employed and the sensitivity of NAT test used. The limitations of our in-house MP-NAT consisted of stringent sample preparation requirements, with labor and time involved. The benefits of our MP-NAT were that it acted as a second level of check for ELISA tests, was relatively inexpensive compared to ID-NAT and did not need sophisticated equipment.

  9. Differential cellular recognition pattern to M. tuberculosis targets defined by IFN-γ and IL-17 production in blood from TB + patients from Honduras as compared to health care workers: TB and immune responses in patients from Honduras

    Science.gov (United States)

    2013-01-01

    Background A better understanding of the quality of cellular immune responses directed against molecularly defined targets will guide the development of TB diagnostics and identification of molecularly defined, clinically relevant M.tb vaccine candidates. Methods Recombinant proteins (n = 8) and peptide pools (n = 14) from M. tuberculosis (M.tb) targets were used to compare cellular immune responses defined by IFN-γ and IL-17 production using a Whole Blood Assay (WBA) in a cohort of 148 individuals, i.e. patients with TB + (n = 38), TB- individuals with other pulmonary diseases (n = 81) and individuals exposed to TB without evidence of clinical TB (health care workers, n = 29). Results M.tb antigens Rv2958c (glycosyltransferase), Rv2962c (mycolyltransferase), Rv1886c (Ag85B), Rv3804c (Ag85A), and the PPE family member Rv3347c were frequently recognized, defined by IFN-γ production, in blood from healthy individuals exposed to M.tb (health care workers). A different recognition pattern was found for IL-17 production in blood from M.tb exposed individuals responding to TB10.4 (Rv0288), Ag85B (Rv1886c) and the PPE family members Rv0978c and Rv1917c. Conclusions The pattern of immune target recognition is different in regard to IFN-γ and IL-17 production to defined molecular M.tb targets in PBMCs from individuals frequently exposed to M.tb. The data represent the first mapping of cellular immune responses against M.tb targets in TB patients from Honduras. PMID:23497342

  10. Particle dynamics during electronic sputtering of solid krypton

    DEFF Research Database (Denmark)

    Dutkiewicz, L.; Pedrys, R.; Schou, Jørgen

    1995-01-01

    We have modeled electronic sputtering of solid krypton by excimer production with molecular dynamics. Both excimer evolution in the solid and deexcitation processes have been incorporated in the simulation. The excimer dynamics in the lattice has been analyzed: the excimers formed near the surface...

  11. Identification of krypton Kr XVIII to Kr XXIX spectra excited in TFR Tokamak plasmas

    International Nuclear Information System (INIS)

    Wyart, J.F.

    1985-02-01

    The emission spectrum of krypton (injected into TFR tokamak plasmas) has been recorded photographically in the 15-300 A spectral range by means of a 2m grazing incidence spectrograph. Preliminary identification work, based on isoelectronic regularities from known spectra of other ions and ionization equilibrium calculations, has allowed 48 lines (belonging to the O I, F I, Na I, Mg I, Al I, Ar I and K I sequences) to be identified

  12. Variability of atmospheric krypton-85 activity concentrations observed close to the ITCZ in the southern hemisphere.

    Science.gov (United States)

    Bollhöfer, A; Schlosser, C; Ross, J O; Sartorius, H; Schmid, S

    2014-01-01

    Krypton-85 activity concentrations in surface air have been measured at Darwin, which is located in northern Australia and is influenced by seasonal monsoonal activity. Measurements between August 2007 and May 2010 covered three wet seasons. The mean activity concentration of krypton-85 measured during this period was 1.31±0.02Bqm(-3). A linear model fitted to the average monthly data, using month and monsoon as predictors, shows that krypton-85 activity concentration measured during the sampling period has declined by 0.01Bqm(-3) per year. Although there is no statistically significant difference in mean activity concentration of krypton-85 between wet and dry season, the model implies that activity concentration is higher by about 0.015Bqm(-3) during months influenced by the monsoon when a north westerly flow prevails. Backward dispersion runs using the Lagrangian particle dispersion model Hysplit4 highlight possible source regions during an active monsoon located deep in the northern hemisphere, and include reprocessing facilities in Japan and India. However, the contribution of these facilities to krypton-85 activity concentrations in Darwin would be less than 0.003Bqm(-3). Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  13. Choice of materials for the immobilization of 85-krypton in a metallic matrix by combined ion implantation and sputtering

    International Nuclear Information System (INIS)

    Whitmell, D.S.

    1985-01-01

    Immobilization in a metal matrix by combined ion implantation and sputtering promises to offer an ideal method for the containment of krypton-85 arising from the reprocessing of nuclear fuel. A 50 kW inactive pilot plant has been built and operated to prepare a copper deposit 22 mm thick weighing 23 kg and containing over 30 liters of inactive gas. The gas incorporation rate exceeded the design figure of 0.3 liters/hour and the vessel was operated at powers up to 30 kW, which corresponds to that envisaged for the industrial vessel. The power consumption was less than 100 kWh/liter. A full-scale vessel (1 m long, 0.26 m diameter) has also been tested at low power. Samples of alternative candidate materials: stainless steel, incoloy, nickel and nickel-lanthanum have been prepared and tested. Nickel appears to be the most promising since it incorporates gas with an efficiency 70% greater than copper and also retains the gas to a temperature at least 100 0 C higher than copper. Tests are being carried out with 100 Curies of radioactive krypton in order to demonstrate that the process will operate satisfactorily at the high internal β irradiation levels that will exist in an active plant and to prepare samples containing krypton-85 for long term leakage measurements and for assessment of any effects caused by the build-up of the decay product rubidium

  14. Clinical usefulness of T1-201 myocardial scintigraphy and diastolic phase index by gated cardiac blood pool imaging in patients with hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Ohmine, Hiromi; Nishimura, Tsunehiko; Hayashida, Kohhei; Uehara, Toshiisa; Kozuka, Takahiro

    1984-01-01

    Tl-201 myocardial scintigraphy and gated cardiac blood pool imaging with Tc-99m were performed at rest in 24 hypertrophic cardiomyopathy (HCM) and 11 normal subjects. Based on visual analysis of Tl-201 myocardial scintigraphies, patients with HCM were subdivided into the following four groups; type I: non-obstructive, type II: obstructive, type III: asymmetric septal hypertrophy, type IV: apical hypertrophy. Characteristic myocardial hypertrophy of each group was also confirmed from the profile curves of circumferential analysis. First third filling fraction (1/3 FF) and mean first third filling rate (1/3 FRm) were obtained from gated cardiac blood pool imaging. As compaired with the normal subjects, 1/3 FF was not so sensitive for the detection of left ventricular hypertrophy. Mean+-S.D. of 1.3 FRm were 1.96+-0.56/sec (normal group), 1.30+-0.44/sec (typ e I), 1.18+-0.63/sec (type II), 1.17+-0.14/sec (type III), and 1.26+-0.03/sec (type IV). We considered that 1/3 FRm was a useful diastolic phase index in the diagnosis of HCM. (author)

  15. Oxygen sensitivity of krypton and Lyman-alpha hygrometers

    NARCIS (Netherlands)

    Dijk, van A.; Kohsiek, W.; Bruin, de H.A.R.

    2003-01-01

    The oxygen sensitivity of krypton and Lyman-¿ hygrometers is studied. Using a dewpoint generator and a controlled nitrogen/oxygen flow the extinction coefficients of five hygrometers associated with the third-order Taylor expansion of the Lambert¿Beer law around reference conditions for oxygen and

  16. Status of the NA62 liquid krypton electromagnetic calorimeter Level 0 trigger processor

    CERN Document Server

    Bonaiuto, V; Fucci, A; Paoluzzi, G; Salamon, A; Salina, G; Santovetti, E; Sargeni, F; Venditti, S

    2013-01-01

    The NA62 experiment at the CERN SPS aims to measure the Branching Ratio of the very rare kaon decay K(+)→π(+)νbar nu collecting O(100) events with a 10% background in two years of data taking. To reject the K(+)→π(+)π(0) background the NA48 liquid krypton calorimeter will be used in the 1-10 mrad angular region. The status of the Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger is presented.

  17. X-ray spectroscopic measurements of dielectronic recombination of highly charged krypton ions

    International Nuclear Information System (INIS)

    Biedermann, C.; Fuchs, T.; Liebisch, P.; Radtke, R.; Behar, E.; Doron, R.

    1999-01-01

    We have performed X-ray spectroscopic measurements of the dielectronic recombination (DR) resonance strengths for the KLn (n = 2, .., 5) series of He-, Li-, and Be-like krypton ions. The ions were produced with an electron beam ion trap, and the strengths were obtained from a fit procedure that compares the experimental excitation function for DR to theory. The results agree well with the predictions. By looking at the KLL resonance, the time evolution of different krypton charge states was measured with this technique and compared with a model of the trap inventory. (orig.)

  18. Experimental Investigations of a Krypton Stationary Plasma Thruster

    Directory of Open Access Journals (Sweden)

    A. I. Bugrova

    2013-01-01

    Full Text Available Stationary plasma thrusters are attractive electric propulsion systems for spacecrafts. The usual propellant is xenon. Among the other suggested propellants, krypton could be one of the best candidates. Most studies have been carried out with a Hall effect thruster previously designed for xenon. The ATON A-3 developed by MSTU MIREA (Moscow initially defined for xenon has been optimized for krypton. The stable high-performance ATON A-3 operation in Kr has been achieved after optimization of its magnetic field configuration and its optimization in different parameters: length and width of the channel, buffer volume dimensions, mode of the cathode operation, and input parameters. For a voltage of 400 V and the anode mass flow rate of 2.5 mg/s the anode efficiency reaches 60% and the specific impulse reaches 2900 s under A-3 operating with Kr. The achieved performances under operation A-3 with Kr are presented and compared with performances obtained with Xe.

  19. Influence of krypton atoms on the structure of hydrogenated amorphous carbon deposited by plasma enhanced chemical vapor deposition

    Science.gov (United States)

    Oliveira, M. H.; Viana, G. A.; de Lima, M. M.; Cros, A.; Cantarero, A.; Marques, F. C.

    2010-12-01

    Hydrogenated amorphous carbon (a-C:H) films were prepared by plasma enhanced chemical vapor deposition using methane (CH4) plus krypton (Kr) mixed atmosphere. The depositions were performed as function of the bias voltage and krypton partial pressure. The goal of this work was to study the influence of krypton gas on the physical properties of a-C:H films deposited on the cathode electrode. Krypton concentration up to 1.6 at. %, determined by Rutherford Back-Scattering, was obtained at high Kr partial pressure and bias of -120 V. The structure of the films was analyzed by means of optical transmission spectroscopy, multi-wavelength Raman scattering and Fourier Transform Infrared spectroscopy. It was verified that the structure of the films remains unchanged up to a concentration of Kr of about 1.0 at. %. A slight graphitization of the films occurs for higher concentration. The observed variation in the film structure, optical band gap, stress, and hydrogen concentration were associated mainly with the subplantation process of hydrocarbons radicals, rather than the krypton ion energy.

  20. Influence of krypton atoms on the structure of hydrogenated amorphous carbon deposited by plasma enhanced chemical vapor deposition

    International Nuclear Information System (INIS)

    Oliveira, M. H. Jr.; Viana, G. A.; Marques, F. C.; Lima, M. M. Jr. de; Cros, A.; Cantarero, A.

    2010-01-01

    Hydrogenated amorphous carbon (a-C:H) films were prepared by plasma enhanced chemical vapor deposition using methane (CH 4 ) plus krypton (Kr) mixed atmosphere. The depositions were performed as function of the bias voltage and krypton partial pressure. The goal of this work was to study the influence of krypton gas on the physical properties of a-C:H films deposited on the cathode electrode. Krypton concentration up to 1.6 at. %, determined by Rutherford Back-Scattering, was obtained at high Kr partial pressure and bias of -120 V. The structure of the films was analyzed by means of optical transmission spectroscopy, multi-wavelength Raman scattering and Fourier Transform Infrared spectroscopy. It was verified that the structure of the films remains unchanged up to a concentration of Kr of about 1.0 at. %. A slight graphitization of the films occurs for higher concentration. The observed variation in the film structure, optical band gap, stress, and hydrogen concentration were associated mainly with the subplantation process of hydrocarbons radicals, rather than the krypton ion energy.

  1. Evaluation of gastrointestinal bleeding by red blood cells labeled in vivo with technetium-99m

    International Nuclear Information System (INIS)

    Winzelberg, G.G.; McKusick, K.A.; Strauss, H.W.; Waltman, A.C.; Greenfield, A.J.

    1979-01-01

    To determine the effectiveness of abdominal imaging with RBCs labeled in vivo with Tc-99m, for the detection of gastrointestinal (GI) bleeding, 28 control subjects and ten patients with suspected bleeding underwent scintigraphy at 0 to 24 hr after tracer injection. Colonic activity was noted in one of the controls within 3 hr of injection, and in five of ten controls at 24 hr, all of whom had initial gastric activity. Of the ten patients with suspected GI bleeding, eight had documented active bleeding; seven of these had positive scintigrams. Nasogastric (NG) suction markedly decreased the presence of initial gastric activity in the patients with active bleeding. With this blood-pool radiopharmaceutical, frequent imaging of the abdomen over 24 hr can be done to test for active bleeding. Continuous NG suction is recommended to reduce accumulation of gastric activity. These results suggest that red blood cells labeled in vivo with Tc-99m provide a sensitive method of detecting active GI bleeding

  2. Synthesis of fluorine-18 radio-labeled serum albumins for PET blood pool imaging

    International Nuclear Information System (INIS)

    Basuli, Falguni; Li, Changhui; Xu, Biying; Williams, Mark; Wong, Karen; Coble, Vincent L.; Vasalatiy, Olga; Seidel, Jurgen; Green, Michael V.; Griffiths, Gary L.; Choyke, Peter L.; Jagoda, Elaine M.

    2015-01-01

    We sought to develop a practical, reproducible and clinically translatable method of radiolabeling serum albumins with fluorine-18 for use as a PET blood pool imaging agent in animals and man. Fluorine-18 radiolabeled fluoronicotinic acid-2,3,5,6-tetrafluorophenyl ester, [ 18 F]F-Py-TFP was prepared first by the reaction of its quaternary ammonium triflate precursor with [ 18 F]tetrabutylammonium fluoride ([ 18 F]TBAF) according to a previously published method for peptides, with minor modifications. The incubation of [ 18 F]F-Py-TFP with rat serum albumin (RSA) in phosphate buffer (pH 9) for 15 min at 37–40 °C produced fluorine-18-radiolabeled RSA and the product was purified using a mini-PD MiniTrap G-25 column. The overall radiochemical yield of the reaction was 18–35% (n = 30, uncorrected) in a 90-min synthesis. This procedure, repeated with human serum albumin (HSA), yielded similar results. Fluorine-18-radiolabeled RSA demonstrated prolonged blood retention (biological half-life of 4.8 hours) in healthy awake rats. The distribution of major organ radioactivity remained relatively unchanged during the 4 hour observation periods either by direct tissue counting or by dynamic PET whole-body imaging except for a gradual accumulation of labeled metabolic products in the bladder. This manual method for synthesizing radiolabeled serum albumins uses fluorine-18, a widely available PET radionuclide, and natural protein available in both pure and recombinant forms which could be scaled up for widespread clinical applications. These preclinical biodistribution and PET imaging results indicate that [ 18 F]RSA is an effective blood pool imaging agent in rats and might, as [ 18 F]HSA, prove similarly useful as a clinical imaging agent

  3. Synthesis of fluorine-18 radio-labeled serum albumins for PET blood pool imaging.

    Science.gov (United States)

    Basuli, Falguni; Li, Changhui; Xu, Biying; Williams, Mark; Wong, Karen; Coble, Vincent L; Vasalatiy, Olga; Seidel, Jurgen; Green, Michael V; Griffiths, Gary L; Choyke, Peter L; Jagoda, Elaine M

    2015-03-01

    We sought to develop a practical, reproducible and clinically translatable method of radiolabeling serum albumins with fluorine-18 for use as a PET blood pool imaging agent in animals and man. Fluorine-18 radiolabeled fluoronicotinic acid-2,3,5,6-tetrafluorophenyl ester, [(18)F]F-Py-TFP was prepared first by the reaction of its quaternary ammonium triflate precursor with [(18)F]tetrabutylammonium fluoride ([(18)F]TBAF) according to a previously published method for peptides, with minor modifications. The incubation of [(18)F]F-Py-TFP with rat serum albumin (RSA) in phosphate buffer (pH9) for 15 min at 37-40 °C produced fluorine-18-radiolabeled RSA and the product was purified using a mini-PD MiniTrap G-25 column. The overall radiochemical yield of the reaction was 18-35% (n=30, uncorrected) in a 90-min synthesis. This procedure, repeated with human serum albumin (HSA), yielded similar results. Fluorine-18-radiolabeled RSA demonstrated prolonged blood retention (biological half-life of 4.8 hours) in healthy awake rats. The distribution of major organ radioactivity remained relatively unchanged during the 4 hour observation periods either by direct tissue counting or by dynamic PET whole-body imaging except for a gradual accumulation of labeled metabolic products in the bladder. This manual method for synthesizing radiolabeled serum albumins uses fluorine-18, a widely available PET radionuclide, and natural protein available in both pure and recombinant forms which could be scaled up for widespread clinical applications. These preclinical biodistribution and PET imaging results indicate that [(18)F]RSA is an effective blood pool imaging agent in rats and might, as [(18)F]HSA, prove similarly useful as a clinical imaging agent. Published by Elsevier Inc.

  4. Completion of Kr-81 and Kr-85 Analysis Development for Hydrogeology and Testing its Validity by Assessing Aquifer Recharge Rates

    International Nuclear Information System (INIS)

    Thonnard, Norbert

    2007-01-01

    The overall objective was to complete the development of a RIMS-based analytical technique to determine the concentration of the rare krypton radioisotopes, 81Kr and 85Kr, in samples of interest to the geoscience and planetary science community The key to RIMS is the use of tunable lasers to selectively and efficiently excite by resonant photon absorption atomic states unique to the chosen element. Ionization of the specified element can then occur while excluding all other constituents of the sample, bringing detection limits down to the single-atom level. Combining RIMS with several steps of isotopic enrichment makes detection of a rare isotope, such as 81Kr, feasible. A complete process for groundwater samples consists of starting with (1) collecting the groundwater sample, (2) degassing the water sample, (3) separating Kr from the recovered gases, (4 and 5) two isotopic enrichments reducing interfering isotopes by >109, and (6) detecting the rare krypton isotope using RIMS in a time-of-flight system. Required water sample size is 20 liters for 81Kr and 10 to 3 liters for 85Kr. Weak links in the above steps were to be identified and rectified. Most of the troublesome issues were resolved, but unfortunately, two key difficulties could not be resolved with the available resources, so the overall, final goal of completing a suite of measurements was not achieved. In spite of this, valuable collaborations were established to demonstrate the value of 81Kr and 85Kr measurements in two critical applications, the future site of a nuclear waste repository, where high efficiency 81Kr measurements would allow groundwater dating of low-yield formations, and a multi-method analysis of potential contamination inflow into a large municipal water system, where the simplicity of interpretation of 85Kr measurements could become a valuable future interpretive tool. Therefore, samples were collected anyway, and processing started using the working parts of the method, so that

  5. Longevity of Wood-Forced Pools in an Old-Growth Forest

    Science.gov (United States)

    Buffington, J. M.; Woodsmith, R. D.; Johnson, A. C.

    2009-12-01

    Wood debris plays an important role in scouring pools in forest channels and providing resultant habitat for aquatic organisms. We investigated the longevity of such pools in a gravel-bed river flowing through old-growth forest in southeastern Alaska by aging trees and “bear’s bread” fungi (Ganoderma applanatum, Fomitopsis pinicola) growing on pool-forming wood debris. Ages were determined by counting annual growth rings from cores and cross sections of trees and fungi growing on the wood debris. These ages are minimum values because they do not account for lag time between debris recruitment and seedling/spore establishment on the debris, nor do they account for flood scour that may periodically reset tree and fungi growth on the debris. The study stream has a gradient of about 1%, bankfull width and depth of 13.3 and 0.78 m, respectively, median grain size of 18 mm, a high wood loading (0.8 pieces/m), and a correspondingly low pool spacing (0.3 bankfull widths/pool), with 81% of the pools forced by wood debris. The size of wood debris in the study stream is large relative to the channel (average log length of 7.6 m and diameter of 0.35 m), rendering most debris immobile. Eighty-one pool-forming pieces of wood were dated over 1.2 km of stream length, with 28% of these pieces causing scour of more than one pool. In all, 122 wood-forced pools were dated, accounting for 38% of all pools at the site and 47% of the wood-forced pools. Fifty-three percent of the wood-forced pools lacked datable wood because these pieces either: were newly recruited; had been scoured by floods; or were contained below the active channel elevation, prohibiting vegetation establishment on the wood debris (the most common cause). The debris age distribution declined exponentially from 2 to 113 yrs., with a median value of 18 yrs. Similar exponential residence time distributions have been reported in other studies, but our analysis focused specifically on the ages of pool-forming wood

  6. Build up of Radioactive Krypton and Xenon Analysis System

    International Nuclear Information System (INIS)

    Lee, D. K.; Choi, C. S.; Chung, K. H.; Lee, W.; Cho, Y. H.; Lee, C. W.

    2008-03-01

    The objective of this project is to build up an analysis system to measure the activity of the atmospheric radioactive krypton and xenon in Korea. The work scopes of the project include the purchase and the installation of the analysis system to measure the activity of the radioactive krypton and xenon in air, and the establishment of the operation capability of the system through the training of the operator. The system consists of two air sampling systems, and one radioactivity analysis system, which incorporates the enrichment system, the gas chromatography to purify a mixture gas, and the gas proportional counter to count the activity of pure krypton and xenon gas. As planned originally, the establishment of the analysis system has been completed. At present, one air sampler is successfully being operated at a specific site of the South Korea to measure the background radioactivities of Kr-85 and Xe-133 in air. The other air sampler is being reserved at the KAERI in the Daejeon for a emergency like the second nuclear test of the North Korea. During the normal time, the reserved air sampler will be used to collect the air sample for the performance test of the analysis system and the cross analysis for the calibration of the system. The radioactivity analysis system has been installed at the KAERI, and is being used to measure the activity of Kr-85 and Xe-133 in the air sample from a domestic site

  7. Iridotomy with red krypton laser.

    Science.gov (United States)

    Yassur, Y; David, R; Rosenblatt, I; Marmour, U

    1986-01-01

    Iridotomy with red krypton laser instead of blue-green argon laser was performed on 68 eyes with various types of angle-closure glaucoma. Patent iridotomy was obtained in all the eyes, mostly in one working session. In eight eyes secondary closure by pigment needed reopening with a few applications at the iridotomy site. There were no immediate or late complications of importance, the main advantage of the technique being the avoidance of the corneal epithelial and endothelial burns which commonly occur during argon laser iridotomy, particularly when the anterior chamber is shallow. PMID:3964628

  8. Arco Vara müüs poole Riia projektist norrakatele / Agnes Ojala

    Index Scriptorium Estoniae

    Ojala, Agnes

    2007-01-01

    Arco Vara tütarettevõte Arco Investeeringute AS ja Arco Vara Läti operatsioonide juht Viktors Savins müüsid poole Riia arendusprojektist Norra ettevõttele Linstow Baltic. Vt. samas: Arco Vara ehitab tivoli kortermaju täis

  9. Blood cell labeling with technetium-99m, (2)

    International Nuclear Information System (INIS)

    Uchida, Tatsumi; Yoshida, Hiroshi; Matsuda, Shin; Kimura, Hideo; Miura, Nobuo

    1978-01-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from 51 Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 μCi of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by 51 Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by 51 Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume. (auth.)

  10. Thermophysical properties of krypton-helium gas mixtures from ab initio pair potentials.

    Science.gov (United States)

    Jäger, Benjamin; Bich, Eckard

    2017-06-07

    A new potential energy curve for the krypton-helium atom pair was developed using supermolecular ab initio computations for 34 interatomic distances. Values for the interaction energies at the complete basis set limit were obtained from calculations with the coupled-cluster method with single, double, and perturbative triple excitations and correlation consistent basis sets up to sextuple-zeta quality augmented with mid-bond functions. Higher-order coupled-cluster excitations up to the full quadruple level were accounted for in a scheme of successive correction terms. Core-core and core-valence correlation effects were included. Relativistic corrections were considered not only at the scalar relativistic level but also using full four-component Dirac-Coulomb and Dirac-Coulomb-Gaunt calculations. The fitted analytical pair potential function is characterized by a well depth of 31.42 K with an estimated standard uncertainty of 0.08 K. Statistical thermodynamics was applied to compute the krypton-helium cross second virial coefficients. The results show a very good agreement with the best experimental data. Kinetic theory calculations based on classical and quantum-mechanical approaches for the underlying collision dynamics were utilized to compute the transport properties of krypton-helium mixtures in the dilute-gas limit for a large temperature range. The results were analyzed with respect to the orders of approximation of kinetic theory and compared with experimental data. Especially the data for the binary diffusion coefficient confirm the predictive quality of the new potential. Furthermore, inconsistencies between two empirical pair potential functions for the krypton-helium system from the literature could be resolved.

  11. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. I. Salicylic, acetylosalicylic, benzoic acids

    Energy Technology Data Exchange (ETDEWEB)

    Toelgyessy, J; Dillinger, P [Slovenska Vysoka Skola Technicka, Bratislava (Czechoslovakia). Chemickotechnologicka Fakulta; Harangozo, M; Jombik, J [Komenskeho Univ., Bratislava (Czechoslovakia). Farmaceuticka Fakulta

    1980-01-01

    A method for the determination of salicylic, acetylsalicylic and benzoic acids in officinal pharmaceutical based on radiometric titration with 0.1 mol.l/sup -1/ NaOH was developed. The end-point was detected with the aid of radioactive glass kryptonate. After the end-point, the excess titrant attacks the glass surface layers and this results in releasing /sup 85/Kr, and consequently, in decreasing the radioactivity of the kryptonate employed. The radioactive kryptonate used as an indicator was prepared by the bombardment of glass with accelerated /sup 85/Kr ions. The developed method is simple, accurate and correct.

  12. Phase analysis of gated blood pool scintigraphy in traumatic myocardial contusion

    International Nuclear Information System (INIS)

    Nishimaki, Hiroshi; Kobayashi, Akiyoshi

    1994-01-01

    It is not easy to make a diagnosis of myocardial contusion following blunt chest trauma, because most patients have many other concurrent injuries with diverse symptoms. The usefulness of phase analysis of gated blood pool scintigraphy (GBPS) for myocardial contusion following blunt chest trauma was evaluated. Thirty-eight patients who had been strongly suspected of having myocardial contusion from clinical symptoms and electrocardiograms underwent phase analysis of GBPS. The results of phase analysis were compared with those of two-dimensional echocardiography (2-D Echo) and CPK-MB fraction measurement in all patients, with those of 201 TlCl myocardial scintigraphy in 35 patients and with those of 99m Tc-pyrophosphate scintigraphy in 10 patients. In 29 patients (76.3%), the results of phase analysis matched those of 2-D Echo. Two patients (5.3%) who were judged as positive by 2-D Echo and as negative by phase analysis had only rupture of the chordae. Only one of two other patients who were judged as negative by 2-D Echo and as positive by phase analysis was judged as positive by 201 TlCl myocardial scintigraphy. The results of both 2-D Echo and phase analysis were not well correlated with those of CPK-MB fraction measurement and 99m Tc pyrophosphate scintigraphy. It is concluded that phase analysis of GBPS, as well as 2-D Echo, is useful for diagnosing myocardial contusion, and that phase analysis is most useful for diagnosing myocardial contusion in patients who cannot be examined by 2-D Echo because of the presence of pneumothorax and/or subcutaneous emphysema in the anterior chest wall. (author)

  13. Phase analysis of gated blood pool scintigraphy in traumatic myocardial contusion

    Energy Technology Data Exchange (ETDEWEB)

    Nishimaki, Hiroshi; Kobayashi, Akiyoshi (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1994-01-01

    It is not easy to make a diagnosis of myocardial contusion following blunt chest trauma, because most patients have many other concurrent injuries with diverse symptoms. The usefulness of phase analysis of gated blood pool scintigraphy (GBPS) for myocardial contusion following blunt chest trauma was evaluated. Thirty-eight patients who had been strongly suspected of having myocardial contusion from clinical symptoms and electrocardiograms underwent phase analysis of GBPS. The results of phase analysis were compared with those of two-dimensional echocardiography (2-D Echo) and CPK-MB fraction measurement in all patients, with those of [sup 201]TlCl myocardial scintigraphy in 35 patients and with those of [sup 99m]Tc-pyrophosphate scintigraphy in 10 patients. In 29 patients (76.3%), the results of phase analysis matched those of 2-D Echo. Two patients (5.3%) who were judged as positive by 2-D Echo and as negative by phase analysis had only rupture of the chordae. Only one of two other patients who were judged as negative by 2-D Echo and as positive by phase analysis was judged as positive by [sup 201]TlCl myocardial scintigraphy. The results of both 2-D Echo and phase analysis were not well correlated with those of CPK-MB fraction measurement and [sup 99m]Tc pyrophosphate scintigraphy. It is concluded that phase analysis of GBPS, as well as 2-D Echo, is useful for diagnosing myocardial contusion, and that phase analysis is most useful for diagnosing myocardial contusion in patients who cannot be examined by 2-D Echo because of the presence of pneumothorax and/or subcutaneous emphysema in the anterior chest wall. (author).

  14. Discovery, photometry, and astrometry of 49 classical nova candidates in M81 galaxy

    Czech Academy of Sciences Publication Activity Database

    Hornoch, Kamil; Scheirich, Peter; Garnavich, P.M.; Hameed, S.; Thilker, D. A.

    2008-01-01

    Roč. 492, č. 1 (2008), s. 301-317 ISSN 0004-6361 Institutional research plan: CEZ:AV0Z10030501 Keywords : M81 galaxy * novae Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 4.153, year: 2008

  15. The effect of annealing unimplanted and krypton implanted uranium dioxide using positrons

    International Nuclear Information System (INIS)

    Evans, H.E.; Rice-Evans, P.; Smith, D.L.; Smith, C.; Evans, J.H.

    1992-01-01

    Previous studies examining the response of variable energy positrons to metals implanted with krypton ions have been extended to UO 2 . The behaviour of two Kr-implanted samples (one implanted at 300 K, the other at 870 K) during annealing up to 1350 K has been followed, together with an unimplanted, as-polished sample. There are several features of interest in the results although in these initial studies the interpretation is not always clear. Defect recovery and krypton effects can be identified but at high temperatures some suggestion of a sensitivity of positrons to stoichiometry is present

  16. Extraction of [99mTc]-d,l-HM-PAO across the blood-brain barrier

    DEFF Research Database (Denmark)

    Andersen, A R; Friberg, H; Knudsen, K B

    1988-01-01

    The initial extraction (E) across the blood-brain barrier (BBB) of [99mTc]-d,l-HM-PAO after intracarotid injection was measured in 14 Wistar rats and 6 patients using the double indicator, single injection method with Na-24 as the cotracer. In both series, cerebral blood flow (CBF) was measured...... was increased from 20 to 120 microliters, while using a 120 microliters bolus containing 10% albumin resulted in a decrease in E. This suggests that HM-PAO binding to albumin is not totally and rapidly reversible during a single passage through brain capillaries and that binding to blood elements may reduce...... the apparent extraction across brain capillaries. In patients using a bolus of 1 ml saline, E decreased linearly with increasing CBF (r = -0.81, p less than 0.001). For a CBF of 0.59 ml/g/min and an average apparent E of 0.72, an apparent PS product of 0.76 ml/g/min was calculated.(ABSTRACT TRUNCATED AT 250...

  17. The NA48 liquid krypton calorimeter

    CERN Document Server

    Gorini, B

    1997-01-01

    The NA48 collaboration goal is to measure the CP violation parameter Re(ɛl/ɛ) at the level of 2 × 10−4. The neutral Kaon decays will be reconstructed by an electromagnetic liquid Krypton calorimeter with fine granularity and a volume almost totally sensible, to obtain excellent position and energy resolution, as well as time resolution. A description of the detector, results from tests of a prototype and the status of the final calorimeter are reported.

  18. H I CLOUDS IN THE M81 FILAMENT AS DARK MATTER MINIHALOS-A PHASE-SPACE MISMATCH

    International Nuclear Information System (INIS)

    Chynoweth, Katie M.; Langston, Glen I.; Holley-Bockelmann, Kelly

    2011-01-01

    Cosmological galaxy formation models predict the existence of dark matter minihalos surrounding galaxies and in filaments connecting groups of galaxies. The more massive of these minihalos are predicted to host H I gas that should be detectable by current radio telescopes such as the Robert C. Byrd Green Bank Telescope (GBT). We observed the region including the M81/M82 and NGC 2403 galaxy groups, searching for observational evidence of an H I component associated with dark matter halos within the 'M81 Filament', using the GBT. The map covers an 8. 0 7 x 21. 0 3 (480 kpc x 1.2 Mpc) region centered between the M81/M82 and NGC 2403 galaxy groups. Our observations cover a wide velocity range, from -890 to 1320 km s -1 , which spans much of the range predicted by cosmological N-body simulations for dark matter minihalo velocities. Our search is not complete in the velocity range -210 to 85 km s -1 , containing Galactic emission and the HVC Complex A. For an H I cloud at the distance of M81, with a size ≤10 kpc, our average 5σ mass detection limit is 3.2 x 10 6 M sun , for a linewidth of 20 km s -1 . We compare our observations to two large cosmological N-body simulations and find that the simulation predicts a significantly greater number of detectable minihalos than are found in our observations, and that the simulated minihalos do not match the phase space of observed H I clouds. These results place strong constraints on the H I gas that can be associated with dark matter halos. Our observations indicate that the majority of extragalactic H I clouds with a mass greater than 10 6 M sun are likely to be generated through tidal stripping caused by galaxy interactions.

  19. TESTING GALAXY FORMATION MODELS WITH THE GHOSTS SURVEY: THE COLOR PROFILE OF M81's STELLAR HALO

    International Nuclear Information System (INIS)

    Monachesi, Antonela; Bell, Eric F.; Bailin, Jeremy; Radburn-Smith, David J.; Dalcanton, Julianne J.; Vlajić, Marija; De Jong, Roelof S.; Streich, David; Holwerda, Benne W.

    2013-01-01

    We study the properties of the stellar populations in M81's outermost part, which hereafter we will call the stellar halo, using Hubble Space Telescope (HST) Advanced Camera for Surveys observations of 19 fields from the GHOSTS survey. The observed fields probe the stellar halo out to a projected distance of ∼50 kpc from the galactic center. Each field was observed in both F606W and F814W filters. The 50% completeness levels of the color-magnitude diagrams (CMDs) are typically at 2 mag below the tip of the red giant branch (TRGB). Fields at distances closer than 15 kpc show evidence of disk-dominated populations whereas fields at larger distances are mostly populated by halo stars. The red giant branch (RGB) of the M81's halo CMDs is well matched with isochrones of ∼10 Gyr and metallicities [Fe/H] ∼ – 1.2 dex, suggesting that the dominant stellar population of M81's halo has a similar age and metallicity. The halo of M81 is characterized by a color distribution of width ∼0.4 mag and an approximately constant median value of (F606W – F814W) ∼1 mag measured using stars within the magnitude range 23.7 ∼ 15 kpc, we detect no color gradient in the stellar halo of M81. We place a limit of 0.03 ± 0.11 mag difference between the median color of RGB M81 halo stars at ∼15 and at 50 kpc, corresponding to a metallicity difference of 0.08 ± 0.35 dex over that radial range for an assumed constant age of 10 Gyr. We compare these results with model predictions for the colors of stellar halos formed purely via accretion of satellite galaxies. When we analyze the cosmologically motivated models in the same way as the HST data, we find that they predict no color gradient for the stellar halos, in good agreement with the observations.

  20. Immobilization of krypton in a metallic matrix by combined ion implantation and sputtering

    International Nuclear Information System (INIS)

    Whitmell, D.S.

    1980-01-01

    With the increase in nuclear power, it may be necessary to contain for 100 to 200 years the radioactive 85 krypton released during fuel reprocessing. The ideal method of immobilizing radioactive materials is in the form of stable, monolithic solids which are resistant to the effects of the environment or accidents, and which can retain the radioactivity under all envisaged conditions. Since krypton is a rare gas, not forming thermally stable compounds, conventional methods of storage are not possible. A process is being developed to immobilize the krypton in the form of small gas bubbles in a metal matrix by implanting the gas into a metal layer from a glow discharge and then burying the implanted layer by sputter deposition. By repeating the process, a thick layer of deposit is built up with the krypton dispersed throughout the matrix as bubbles of diameter less than 20 A. This process offers an ideal form of storage since gas in bubbles is not thermally released until the temperature of the matrix is close to the melting point, and also leakage of gas by corrosion or mechanical damage will be small. A pilot plant is being built in order to demonstrate the process on a scale comparable with that required for a reprocessing plant. The efficiency of the process is dependent upon the amount of gas which can be implanted at low energy into a thin layer and its subsequent retention. (author)

  1. Answers to questions about removing krypton from the Three Mile Island, Unit 2 reactor building. Public information report

    International Nuclear Information System (INIS)

    1980-05-01

    This document presents answers to frequently asked questions about the probable effects of controlled releases of the krypton presently contained within the reactor building of Three Mile Island, Unit 2. Also answered are questions about alternative means for removing the krypton

  2. ATTA-3: a State-of-the-Art Instrument for Radio-Krypton Dating

    Science.gov (United States)

    Jiang, W.; Zappala, J. C.; Bailey, K.; Lu, Z.; Müller, P.; O'Connor, T. P.

    2013-12-01

    The ATTA-3 instrument at Argonne has recently enabled routine Kr-81 dating. The instrument is based on Atom Trap Trace Analysis (ATTA), a novel laser based atom counting technique that allows detection of long lived noble gas radioisotopes (Kr-81, Kr-85 and Ar-39) with extremely low abundance (1E-16 to 1E-10). At the center of the instrument is a magneto-optical trap (MOT), which traps and counts only the atoms of the desired isotope. This unique feature makes ATTA free of interference from any other isotopes or molecular species. For Kr-81 dating in the age range of 150 - 1,500 kyr, the required sample size is 5 - 10 micro-L STP of krypton gas, which can be extracted from approximately 100 - 200 kg of water or 40 - 80 kg of ice. Several recent developments in our lab may lead to further improvements to the current ATTA-3 apparatus: 1) The isotopic abundance ratio between the unknown, rare isotope (either Kr-81 or Kr-85) and the stable, abundant isotope (Kr-83) is measured. Here the stable isotope serves as a control isotope. A new method has been developed that allows more accurate measurements of the control isotope Kr-83. Combined with the ability to measure the rare Kr-81 and Kr-85 isotopes, this scheme allows ATTA-3 to directly determine 81Kr/Kr and 85Kr/Kr ratios without other supplemental measurements, to reduce the overall uncertainties of the measured isotope ratios, and also to improve the long term stability of the system. 2) The current capacity of the ATTA-3 instrument is about 120 samples per year. The throughput is mainly limited by the so called 'memory effect', which is caused by the residual samples trapped in the system after each measurement. These residual samples are gradually released in subsequent measurements, causing cross-sample contaminations. In order to mitigate this problem, we wash the system with a xenon discharge for about 36 hours between measurements. This practice limits the overall sample processing speed. Preliminary

  3. Krypton separation from waste gas of a reprocessing plant by low temperature rectification

    International Nuclear Information System (INIS)

    1987-01-01

    6 lectures at this seminar describe and evaluate the results of the research and development work on low temperature krypton separation from the waste gas of the reprocessing of nuclear fuels. They are used for making decisions for the process to be used in the future on a large scale at the Wackersdorf reprocessing plant. 2 further lectures deal with alternatives to this process, which were also developed: the freon washing and low temperature adsorption of krypton. All the lectures were included separately in the INIS and ENERGY databases. (RB) [de

  4. Efficient Translation of Epstein-Barr Virus (EBV) DNA Polymerase Contributes to the Enhanced Lytic Replication Phenotype of M81 EBV.

    Science.gov (United States)

    Church, Trenton Mel; Verma, Dinesh; Thompson, Jacob; Swaminathan, Sankar

    2018-03-15

    Epstein-Barr virus (EBV) is linked to the development of both lymphoid and epithelial malignancies worldwide. The M81 strain of EBV, isolated from a Chinese patient with nasopharyngeal carcinoma (NPC), demonstrates spontaneous lytic replication and high-titer virus production in comparison to the prototype B95-8 EBV strain. Genetic comparisons of M81 and B95-8 EBVs were previously been performed in order to determine if the hyperlytic property of M81 is associated with sequence differences in essential lytic genes. EBV SM is an RNA-binding protein expressed during early lytic replication that is essential for virus production. We compared the functions of M81 SM and B95-8 SM and demonstrate that polymorphisms in SM do not contribute to the lytic phenotype of M81 EBV. However, the expression level of the EBV DNA polymerase protein was much higher in M81- than in B95-8-infected cells. The relative deficiency in the expression of B95-8 DNA polymerase was related to the B95-8 genome deletion, which truncates the BALF5 3' untranslated region (UTR). Similarly, the insertion of bacmid DNA into the widely used recombinant B95-8 bacmid creates an inefficient BALF5 3' UTR. We further showed that the while SM is required for and facilitates the efficient expression of both M81 and B95-8 mRNAs regardless of the 3' UTR, the BALF5 3' UTR sequence is important for BALF5 protein translation. These data indicate that the enhanced lytic replication and virus production of M81 compared to those of B95-8 are partly due to the robust translation of EBV DNA polymerase required for viral DNA replication due to a more efficient BALF5 3' UTR in M81. IMPORTANCE Epstein-Barr virus (EBV) infects more than 90% of the human population, but the incidence of EBV-associated tumors varies greatly in different parts of the world. Thus, understanding the connection between genetic polymorphisms from patient isolates of EBV, gene expression phenotypes, and disease is important and may help in

  5. Comparison in the analytical performance between krypton and argon glow discharge plasmas as the excitation source for atomic emission spectrometry.

    Science.gov (United States)

    Wagatsuma, Kazuaki

    2009-04-01

    The emission characteristics of ionic lines of nickel, cobalt, and vanadium were investigated when argon or krypton was employed as the plasma gas in glow discharge optical emission spectrometry. A dc Grimm-style lamp was employed as the excitation source. Detection limits of the ionic lines in each iron-matrix alloy sample were compared between the krypton and the argon plasmas. Particular intense ionic lines were observed in the emission spectra as a function of the discharge gas (krypton or argon), such as the Co II 258.033 nm for krypton and the Co II 231.707 nm for argon. The explanation for this is that collisions with the plasma gases dominantly populate particular excited levels of cobalt ion, which can receive the internal energy from each gas ion selectively, for example, the 3d(7)4p (3)G(5) (6.0201 eV) for krypton and the 3d(7)4p (3)G(4) (8.0779 eV) for argon. In the determination of nickel as well as cobalt in iron-matrix samples, more sensitive ionic lines could be found in the krypton plasma rather than the argon plasma. Detection limits in the krypton plasma were 0.0039 mass% Ni for the Ni II 230.299-nm line and 0.002 mass% Co for the Co II 258.033-nm line. However, in the determination of vanadium, the argon plasma had better analytical performance, giving a detection limit of 0.0023 mass% V for the V II 309.310-nm line.

  6. Experimental study of X-ray emission yield in a Filippov-type Plasma Focus operating in neon and neon-krypton mixture

    International Nuclear Information System (INIS)

    Babazadeh, A.R.; Kiai, S.M.S.; Roshan, M.V.; Emami, M.

    2002-01-01

    Since the installation of PF-DENA at AEOI about one year ago, we performed quantitative studies of variation of X-ray radiations from a new Filippov-type plasma focus device: Dena (90 kJ, 25 kV, 288 μF). The operating gas was neon at a constant pressure of 1 torr and different pressures of krypton admixture (up to 0.3 torr), with the discharge voltage up to 18 kV. For charging voltage of 17 kV with 41 kJ stored energy and spark gap pressure of 1.2x 10 -2 torr, the maximum soft and little hard X-ray (SXR-HXR) emission is found for the neon, resulting in a total SXR yield of 2 V/shot measured by silicon semiconductor diode detectors. Concerning the effect of krypton admixture, a maximum intensity of SXR radiation has been observed at low krypton pressure that is about 1 V/shot. At higher pressure, the quality of SXR emission decreases down to zero. However, the maximum intensity of the HXR radiation yield in the same pressure range was found to be 2.5 V/shot. By increasing the pressure of krypton up tp 0.3 torr, the results show that the krypton admixture gas generally causes, a decrease of the SXR radiation yield down to zero, whereas, the HXR emission yield carries a maximum value at the optimum pressure of krypton that is about 0.1 torr. Nevertheless, the pressure increments of krypton lead to decreasing in the discharge voltage for the maximum X-ray production. (author)

  7. In Situ Measurement of Atmospheric Krypton and Xenon on Mars with Mars Science Laboratory

    Science.gov (United States)

    Conrad, P. G.; Malespin, C. A.; Franz, H. B.; Pepin, R. O.; Trainer, M. G.; Schwenzer, S. P.; Atreya, S. K.; Freissinet, C.; Jones, J. H.; Manning, H.; hide

    2016-01-01

    Mars Science Laboratorys Sample Analysis at Mars (SAM) investigation has measured all of the stable isotopes of the heavy noble gases krypton and xenon in the martian atmosphere, in situ, from the Curiosity Rover at Gale Crater, Mars. Previous knowledge of martian atmospheric krypton and xenon isotope ratios has been based upon a combination of the Viking missions krypton and xenon detections and measurements of noble gas isotope ratios in martian meteorites. However, the meteorite measurements reveal an impure mixture of atmospheric, mantle, and spallation contributions. The xenon and krypton isotopic measurements reported here include the complete set of stable isotopes, unmeasured by Viking. The new results generally agree with Mars meteorite measurements but also provide a unique opportunity to identify various non-atmospheric heavy noble gas components in the meteorites. Kr isotopic measurements define a solar-like atmospheric composition, but deviating from the solar wind pattern at 80Kr and 82Kr in a manner consistent with contributions originating from neutron capture in Br. The Xe measurements suggest an intriguing possibility that isotopes lighter than 132Xe have been enriched to varying degrees by spallation and neutron capture products degassed to the atmosphere from the regolith, and a model is constructed to explore this possibility. Such a spallation component, however, is not apparent in atmospheric Xe trapped in the glassy phases of martian meteorites.

  8. State-of-the-art ab initio potential energy curve for the krypton atom pair and thermophysical properties of dilute krypton gas.

    Science.gov (United States)

    Jäger, Benjamin; Hellmann, Robert; Bich, Eckard; Vogel, Eckhard

    2016-03-21

    A new reference krypton-krypton interatomic potential energy curve was developed by means of quantum-chemical ab initio calculations for 36 interatomic separations. Highly accurate values for the interaction energies at the complete basis set limit were obtained using the coupled-cluster method with single, double, and perturbative triple excitations as well as t-aug-cc-pV5Z and t-aug-cc-pV6Z basis sets including mid-bond functions, with the 6Z basis set being newly constructed for this study. Higher orders of coupled-cluster terms were considered in a successive scheme up to full quadruple excitations. Core-core and core-valence correlation effects were included. Furthermore, relativistic effects were studied not only at a scalar relativistic level using second-order direct perturbation theory, but also utilizing full four-component and Gaunt-effect computations. An analytical pair potential function was fitted to the interaction energies, which is characterized by a depth of 200.88 K with an estimated standard uncertainty of 0.51 K. Thermophysical properties of low-density krypton were calculated for temperatures up to 5000 K. Second and third virial coefficients were obtained from statistical thermodynamics. Viscosity and thermal conductivity as well as the self-diffusion coefficient were computed using the kinetic theory of gases. The theoretical results are compared with experimental data and with results for other pair potential functions from the literature, especially with those calculated from the recently developed ab initio potential of Waldrop et al. [J. Chem. Phys. 142, 204307 (2015)]. Highly accurate experimental viscosity data indicate that both the present ab initio pair potential and the one of Waldrop et al. can be regarded as reference potentials, even though the quantum-chemical methods and basis sets differ. However, the uncertainties of the present potential and of the derived properties are estimated to be considerably lower.

  9. Present and future potential of krypton-85 for the detection of clandestine reprocessing plants for treaty verification.

    Science.gov (United States)

    Schoeppner, Michael; Glaser, Alexander

    2016-10-01

    Burnup calculations are applied to determine the amount of krypton-85 that is produced during the irradiation of nuclear fuel. Since krypton-85 is most likely released into the atmosphere during reprocessing to separate plutonium, atmospheric transport modeling is used to calculate the worldwide distribution of krypton-85 concentrations stemming from emissions from declared reprocessing plants. The results are the basis for scenarios in which emissions from clandestine reprocessing facilities have to be detected against various background levels. It is concluded that today's background imposes heavily on the ability to detect small and medium plutonium separation rates; only high separation rates of 1 SQ per week and higher have a chance to be detected with feasible outlay. A fixed network of monitoring stations seems too costly; instead the high number of samples that are required rather calls for mobile sampling procedures, where air samples are collected at random locations over the world and are analyzed in regional laboratories for their krypton-85 concentration. Further, it is argued that krypton-85 emissions from declared reprocessing activities have to be significantly lowered to enable a worldwide verification of the absence of even smaller clandestine reprocessing. For each scenario the number of samples that have to be taken for probable detection is calculated. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Generalized oscillator strengths for some higher valence-shell excitations of krypton atom

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The valence-shell excitations of krypton atom have been investigated by fast electron impact with an angle-resolved electron-energy-loss spectrometer. The generalized oscillator strengths for some higher mixed valence-shell excitations in 4d, 4f, 5p, 5d, 6s, 6p, 7s ← 4p of krypton atom have been determined. Their profiles are discussed, and the generalized oscillator strengths for the electric monopole and quadrupole excitations in 5p ← 4p are compared with the calculations of Amusia et al. (Phys. Rev. A 67 022703 (2003)). The differences between the experimental results and theoretical calculations show that more studies are needed.

  11. Radionuclide angiography and blood pool imaging to assess skin ulcer healing prognosis in patients with peripheral vascular disease

    International Nuclear Information System (INIS)

    Alazraki, N.; Lawrence, P.F.; Syverud, J.B.

    1984-01-01

    Several non-invasive diagnostic techniques including segmental limb blood pressures, skin fluoresence, and photo plethysmography, have been evaluated as predictors of skin ulcer healing in patients with peripheral vascular disease, but none are widely used. Using 20mCi of Tc-99m phosphate compounds, four phase bone scans were obtained, including (1) radionuclide angiogram (2) blood pool image (3) 2 hour and 4-6 hour static images and (4) 24 hour static delayed images. The first two phases were used to assess vacularity to the region of distal extremity ulceration; the last two phases evaluated presence or absence of osteomyelitis. Studies were performed in 30 patients with non-healing ulcers of the lower extremities. Perfusion to the regions of ulceration on images was graded as normal, increased, or reduced with respect to the opposite (presumed normal) limb or some other normal reference area. Hypervascular response was interpreted as good prognosis for healing unless osteomyelitis was present. Clinicians followed patients for 14 days to assess limb healing with optimum care. If there was no improvement, angiography and/or surgery (reconstructive surgery, sympathectomy, or amputation) was done. Results showed: sensitivity for predicting ulcer healing was 94%, specificity 89%. Patients who failed to heal their ulcers showed reduced perfusion, no hypervascular response, or osteomyelitis. Microcirculatory adequacy for ulcer healing appear predictable by this technique

  12. [Responsibility of the physician for blood samples according to paragraph 81 a StPO?].

    Science.gov (United States)

    Blank, J H

    1992-03-01

    On principle no physician is under obligation to take blood-tests prescribed in Art. 81 a StPO (Code of Criminal Procedure). However, this principle is not valid without exception. Hence to be appointed expert by a judge or a public prosecutor shall give the reason for a legal pledge. An indirect obligation--but not to police authorities--may result from a contractually stipulated assumption or from being part of the Public Health Service staff. For the physician being employed in a hospital, the special rule 2 c fig. 3 par. 1 BAT (Federal Employees Tariff Treaty) is valid, which stipulates an obligation to take blood-tests, even if a contractual agreement is missing. Violation of contract and offence against legal pledges may justify giving notice to the physician. However, the obligation of taking blood-tests is not unlimited. Within the pale of law rights of refusal are stated in Art. 22, 24, 52, 72, 74 StPO (Code of Criminal Procedure). Moreover a refusal is justified, if the manoeuvre is injurious to health of the accused under consideration. In this case the physician on the spot taking blood-tests has got the exclusive responsibility, which cannot be shifted on to other authorities. In case of personally justified refusal the physician does not have to expect any prejudices. A physician refusing to take blood-tests does not incur a penalty under Art. 258 or Art. 258 a StGB (Criminal Code).

  13. Interdiffusion of krypton and xenon in high-pressure helium

    International Nuclear Information System (INIS)

    Campana, R.J.; Jensen, D.D.; Epstein, B.D.; Hudson, R.G.; Baldwin, N.L.

    1980-01-01

    The interdiffusion of gaseous fission products in high-pressure helium is an important factor in the control of radioactivity in gas-cooled fast breeder reactors (GCFRs). As presently conceived, GCFRs use pressure-equalized and vented fuel in which fission gases released from the solid matrix oxide fuel are transported through the fuel rod interstices and internal fission product traps to the fuel assembly vents, where they are swept away to external traps and storage. Since the predominant transport process under steady-state operating conditions is interdiffusion of gaseous fission products in helium, the diffusion properties of krypton-helium and xenon-helium couples have been measured over the range of GCFR temperature and pressure conditions ( -1 ) and expected temperature dependence to the 1.66 power (Tsup(1.66)) at lower pressures and temperatures. Additional work is in progress to measure the behaviour of the krypton-helium and xenon-helium couples in GCFR fuel rod charcoal delay traps. (author)

  14. Pooled HIV-1 viral load testing using dried blood spots to reduce the cost of monitoring antiretroviral treatment in a resource-limited setting.

    Science.gov (United States)

    Pannus, Pieter; Fajardo, Emmanuel; Metcalf, Carol; Coulborn, Rebecca M; Durán, Laura T; Bygrave, Helen; Ellman, Tom; Garone, Daniela; Murowa, Michael; Mwenda, Reuben; Reid, Tony; Preiser, Wolfgang

    2013-10-01

    Rollout of routine HIV-1 viral load monitoring is hampered by high costs and logistical difficulties associated with sample collection and transport. New strategies are needed to overcome these constraints. Dried blood spots from finger pricks have been shown to be more practical than the use of plasma specimens, and pooling strategies using plasma specimens have been demonstrated to be an efficient method to reduce costs. This study found that combination of finger-prick dried blood spots and a pooling strategy is a feasible and efficient option to reduce costs, while maintaining accuracy in the context of a district hospital in Malawi.

  15. Separation, storage, and disposal of krypton-85: status and projects

    Energy Technology Data Exchange (ETDEWEB)

    Laser, M.

    1976-09-15

    Despite the relatively small impact of 85Kr to man the separation of fission krypton from the off-gas of fuel reprocessing plants must be taken into account. Combined with other advantages also in power reactor stations the retention of 85Kr seems to be attractive. Cryogenic processes are favored worldwide, because the technology has been well proven during several decades in air liquefaction and separation plants. Relatively small modifications must be made to adjust these processes to fission gas separation plants. Some fundamental data however are necessary for the design of a plant. Besides cryogenic processes a liquid adsorption for reprocessing off-gases and charcoal adsorption processes for reactor off-gas are under discussion. The retained krypton can be stored under air or water cooling in usual pressurized steel cylinders. However, legal problems may arise. The steel cylinders can be stored in engineered storage facilities for an intermediate period or finally. In Europe, however, the final storage will be questionable. Therefore, the dumping of 85Kr into the deep sea has been proposed. For this reason a revision of the London Convention is necessary, because the dumping of 85/Kr has not been specified. The IAEA as competent authority is asked to define the conditions for dumping. Injection of krypton containing gases into porous geologic strata may also be possible, if a very small release can be guaranteed.

  16. Radiation protect during the ventilation scintigraphy of Tc99m DTPA radioaerosol in pediatric application

    International Nuclear Information System (INIS)

    Chen, Yu-Wen; Dai, Zen-Kong; Huang, Ying-Fong; Jong, Shiang-Bing

    2000-01-01

    Lung ventilation-perfusion scintigraphy is of great value for the management of patients with both primary lung disease and heart disease, by proving patho- physiological information of importance for the diagnosis, follow-up and functional evaluation of the patients. Krypton 81m radioactive gas is preferable for pediatric application due to its short half-life. However, the rubidium-krypton 81m generator is not popular in hospital of our country. Tc99m DTPA radioaerosol ventilation scintigraphy has its unique convenient for clinical application. But, the most disadvantage of clinical application of Tc99m DTPA radioaerosol is contamination of environment when the poor-cooperative patient can't breathe by mouth. For this reason, we design the certain procedure to reduce the radioaerosol contamination. During May to Aug., 1999, we collect 36 pediatric patients (male to female ratio 2:1, age from 6 months to 20 years old) with clinical history of lung or heart disease, including congenital heart disease, asthma and so on. Before the cases receive 10 to 15 mCi Tc99m DTPA radioaerosol ventilation scan, all of them were trained with breath training. And during the ventilation scintigraphy, the special mouth mask is designed to prevent the radioaerosol leakage into atmosphere. Then Geiger-Muller survey meter was arranged to detect the environmental contamination of radioaerosol in the mask, one and two metes away from the mask every 10 minutes during ventilation scintigraphy procedure and 1 hour after finishing image. Two nuclear medicine physicians evaluated imaging quality of ventilation scintigraphy. Results: Among thirty-six pediatric patients with prior breath training, thirty-two cases are successful to proceed the Tc99m DTPA ventilation scintigraphy. The other four cases that were under three-year-old fail to receive ventilation scintigraphy. There is limited detectable radioactivity in the mouth mask at early 10 minute by Geiger-Muller counter. No significant

  17. Climate risks by radioactive krypton-85 from nuclear fission. Atmospheric-electrical and air-chemical effects of ionizing radiation in the atmosphere

    International Nuclear Information System (INIS)

    Kollert, R.

    1994-01-01

    The study shows that krypton-85 from nuclear fission enhances air ionization and, thus, interferes with the atmospheric-electrical system and the water balance of the earth atmosphere. This is reason for concern: There are unforeseeable effects for weather and climate if the krypton-85 content of the earth atmosphere continues to rise. There may be a krypton-specific greenhouse effect and a collapse of the natural atmospheric-electrical field. In addition, human well-being may be expected to be impaired as a result of the diminished atmospheric-electrical field. There is also the risk of radiochemical actions and effects caused-by krypton-85-containing plumes in other air-borne pollutants like the latters' transformation to aggressive oxidants. This implies radiation smog and more acid rain in the countries exposed. This study summarizes findings gained in these issues by various sciences, analyses them and elaborates hypotheses on the actions and effects of krypton-85 on the air, the atmosphere and the climate. (orig./HP) [de

  18. S-process krypton of variable isotopic composition in the Murchison meteorite

    Science.gov (United States)

    Ott, Urlich; Begemann, Friedrich; Yang, Yongmann; Epstein, Samuel

    1988-01-01

    Data are reported which, for the first time, permit the derivation of the full isotopic spectrum of s-process krypton with reasonable precision. It is shown that this s-Kr in a residue from the Murchison meteorite did not originate in one single s-process but rather is a mixture of contributions from stellar environments where the density of free neutrons was not the same. The astrophysical conditions under which this krypton was produced were distinct from those that have been invoked to explain the solar system s-process abundance. Similar to the C-13-rich carbon component in an aliquot of the same residue, the s-process Kr from different astrophysical sites has retained its identity during the accumulation and subsequent history of the meteorite.

  19. S-process krypton of variable isotopic composition in the Murchison meteorite

    International Nuclear Information System (INIS)

    Ott, U.; Begemann, F.; Yang, J.; Epstein, S.

    1988-01-01

    We report data that allow us to derive with reasonable precision the full isotopic spectrum of s-process krypton. We show that this s-Kr in a residue from Murchison meteorite did not originate in one single s-process but rather is a mixture of contributions from stellar environments where the density of free neutrons was not the same. The astrophysical conditions under which this krypton has been produced were distinct from those that have been invoked to explain the Solar System s-process abundance. Similar to the 13 C-rich carbon component in an aliquot of the same residue, the s-process Kr from different astrophysical sites has retained its identify during the accumulation and subsequent history of the meteorite. (author)

  20. Study of structural and transport properties of argon, krypton, and their binary mixtures at different temperatures.

    Science.gov (United States)

    Ghimire, Sunil; Adhikari, Narayan Prasad

    2017-03-01

    Molecular dynamics simulation of argon, krypton, and their binary mixtures were performed at different temperatures and constant pressure (P = 1.013 bar) using GROMACS - Groningen Machine for Chemical Simulations. The gases are modeled by Lennard-Jones pair potential, with parameters taken from the literature. The study of radial distribution functions (RDFs) shows a single peak which indicates that there is no packing effect in gaseous state for argon, krypton, and their binary mixtures. The self-diffusion coefficients of argon and krypton is determined by using mean-square displacement(MSD) method and the mutual diffusion coefficients of binary mixtures are determined using Darken's relation. The values of simulated diffusion coefficients are compared with their corresponding theoretical values, numerical estimation, and experimental data. A good agreement between these sets of data is found. The diffusion coefficients obey Arrhenius behavior to a good extent for both pure components and binary mixtures. The values of simulated diffusion coefficient are used to estimate viscosities and thermal conductivities which agree with theoretical values, numerical estimation, and experimental data within 10 %. These results support that the LJ potential is sufficient for description of molecular interactions in argon and krypton.

  1. Determination of SO2 in the atmosphere using radioactive iodine kryptonate as impregnation medium of chromatographic paper

    International Nuclear Information System (INIS)

    Pruzinec, J.

    1975-01-01

    Chromatographic paper was impregnated with radioiodine kryptonate using the macrodiffusion technique. The decrease with time of the activity of the kryptonate-impregnated paper exposed to SO 2 -contaminated air was measured. From the decrease in chromatographic paper activity, the concentration of SO 2 was determined in the range 300 to 700 ppm. (A.K.)

  2. A survey of methods for separating and immobilizing krypton-85 arising from a nuclear fuel reprocessing plant

    International Nuclear Information System (INIS)

    Taylor, P.

    1990-12-01

    This report reviews the literature on methods to separate and immobilize krypton-85 arising from dissolution or prior treatment of nuclear fuel in a reprocessing plant. It was prepared as part of a broader review of fuel reprocessing waste management methods that might find future applications in Canada. Cryogenic distillation is the most fully demonstrated method of separation of krypton from off-gases, but it is complex. In particular, it requires pretreatment of the gas stream to eliminate several other components before the final distillation. The most highly developed alternative process is fluorocarbon adsorption, while several other processes have been investigated on a bench scale. The simplest method of storing radioactive krypton is in compressed-gas cylinders, but the risks of accidental release are increased by the corrosive nature of the decay product, rubidium. Encapsulation in either a metal matrix or a hydrothermally vitrified zeolite appears to offer the most secure immobilization of krypton. Processes for both types of material have been demonstrated inactively on a scale approaching that required for treatment of off-gases from a commercial-scale fuel reprocessing plant. Low-operating temperatures and pressures of the metal encapsulation process, compared with encapsulation in zeolites, represent a definite advantage, but electrical power requirements for the former process are relatively high. It appears that suitable technology is available for separation and immobilization of radioactive krypton, should the need arise in Canada in the future

  3. Design and performance characteristics of a krypton chloride (λ ...

    Indian Academy of Sciences (India)

    2014-01-07

    Jan 7, 2014 ... Development of a discharge-pumped krypton chloride (KrCl) laser operating at 222 nm wavelength is demonstrated. In this paper the design, successful realization and operating characteristics of KrCl excimer laser are reported. The laser is driven by a simple and efficient excitation technique using ...

  4. CHEMICAL ABUNDANCES OF SEVEN IRREGULAR AND THREE TIDAL DWARF GALAXIES IN THE M81 GROUP

    International Nuclear Information System (INIS)

    Croxall, Kevin V.; Van Zee, Liese; Lee, Henry; Miller, Bryan W.; Skillman, Evan D.; Lee, Janice C.; Cote, Stephanie; Kennicutt, Robert C.

    2009-01-01

    We have derived nebular abundances for 10 dwarf galaxies belonging to the M81 Group, including several galaxies which do not have abundances previously reported in the literature. For each galaxy, multiple H II regions were observed with GMOS-N at the Gemini Observatory in order to determine abundances of several elements (oxygen, nitrogen, sulfur, neon, and argon). For seven galaxies, at least one H II region had a detection of the temperature sensitive [O III] λ4363 line, allowing a 'direct' determination of the oxygen abundance. No abundance gradients were detected in the targeted galaxies, and the observed oxygen abundances are typically in agreement with the well-known metallicity-luminosity relation. However, three candidate 'tidal dwarf' galaxies lie well off this relation: UGC 5336, Garland, and KDG 61. The nature of these systems suggests that UGC 5336 and Garland are indeed recently formed systems, whereas KDG 61 is most likely a dwarf spheroidal galaxy which lies along the same line of sight as the M81 tidal debris field. We propose that these H II regions formed from previously enriched gas which was stripped from nearby massive galaxies (e.g., NGC 3077 and M81) during a recent tidal interaction.

  5. Inhalation scan using sup(81m)Kr-gas

    International Nuclear Information System (INIS)

    Kobayashi, Hidetoshi; Sasaki, Tsuneo; Senda, Kohei; Ohara, Ken; Kaii, Osamu

    1979-01-01

    Inhalation scan using sup(81m) Kr-gas was performed in the various pulmonary diseases, in order to examine the ventilatory function of the lung after the measurement of ratio of expiratory ratio in the normal and diseased lung field. Inhalation scan is applied to the various pulmonary diseases such as lung cancer, radiation pulmonary fibrosis and chronic obstructive pulmonary disease. In cases of lung cancer, there is disturbance of respiratory function at the site of lesion when compared to the remainder of the normal lung fields. In cases of chronic obstructive pulmonary disease, the inhalation scan is performed at three states such as pre-, in- and post-attack of the disease. During the asthma attack the respiratory function is disturbed considerably when compared to the pre- and post-attack states. In each pulmonary disease, the ratio of expiratory ratio is measured from the histogram and pulmonary function is evaluated. (author)

  6. The color gradient in spiral galaxies: application to M 81

    International Nuclear Information System (INIS)

    Segalovitz, A.

    1975-01-01

    The calculated development of the color of a star cluster is used to predict the expected color evolution, as a function of radius, in a spiral galaxy. It is assumed that the fraction of gas which is converted into stars during a spiral arm passage is a function of radius only. Applying this model to M 81, it is shown that the observed color and mass distributions can be explained by an initial disk-like gas distribution proportional to the inverse square of the radius and a consumption fraction which is an increasing function of radius. (orig.) [de

  7. Experimental studies on the krypton absorption in liquid CO2 (KALC) process

    International Nuclear Information System (INIS)

    Glass, R.W.; Beaujean, H.W.R.; Fowler, V.L.; Gilliam, T.M.; Inman, D.J.; Levins, D.M.

    1976-01-01

    Results are presented for a series of experiments to quantify krypton removal from simulated High-Temperature Gas-Cooled Reactor reprocessing off-gas by the KALC process. The Experimental Engineering Section Off-Gas Decontamination Facility used in the campaign provides engineering-scale experiments with nominal gas and liquid flows of 5 scfm and 0.5 gpm respectively. Equilibrium and nonequilibrium mass transfer experiments for the CO 2 --O 2 --Kr system are described. Data analysis indicates values of HTU for krypton on the order of 0.5 ft for decontamination factors from 100 to 10,000. Recent flooding information for the packed columns is combined with previous data and is shown to be well represented by an empirical flooding equation

  8. 气相色谱氩、氪、氙、氡分离度初步研究%Resolutions on Mixture of Argon, Krypton, Xenon and Radon by Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    刘蜀疆; 陈占营; 常印忠; 王世联; 李奇; 石建芳; 樊元庆; 赵允刚

    2012-01-01

    核爆炸产生多种稀有气体核素,这些核素可作为核泄露监测对象.气相色谱是组分分离的重要手段,在核爆炸监测取样中有重要应用.本文以5A分子筛作为固定相,高纯氮作为流动相,测量了氩、氪、氙、氡在气相色谱中的分离效果.结果表明,在相同色谱条件下,氩、氪分离度小于氪、氙分离度;在柱流量35.6 mL/min、柱温353 K条件下,气相色谱氩、氪,氪、氙,氙、氡分离度均大于2.25.%Radio-isotopes of noble gas, which are produced during nuclear explosion, can escape into atmosphere easily. These isotopes can be measured as good indicators for nuclear explosion. Noble gas monitoring, including sampling, measurement and analysis, became more and more essential. Gas chromatography is an important technology on noble gas separation during gas sampling. In this paper, while 5A molecular sieve was utilized as column stationary state and high-purity nitrogen as column fluid state, resolutions of argon, krypton, xenon and radon were widely investigated under different chromatograph conditions. As a result, the resolution of krypton and argon is less than the resolution of xenon and krypton; when column flow rate is 35. 6 mL/min and oven temperature is 353 K, all of the resolutions of radon and xenon, xenon and krypton, krypton and argon are more than 2. 25.

  9. Hyperpolarized krypton-83 as a contrast agent for magnetic resonance imaging.

    Science.gov (United States)

    Pavlovskaya, Galina E; Cleveland, Zackary I; Stupic, Karl F; Basaraba, Randall J; Meersmann, Thomas

    2005-12-20

    For the first time, magnetic resonance imaging (MRI) with hyperpolarized (hp) krypton-83 (83Kr) has become available. The relaxation of the nuclear spin of 83Kr atoms (I = 9/2) is driven by quadrupolar interactions during brief adsorption periods on surrounding material interfaces. Experiments in model systems reveal that the longitudinal relaxation of hp 83Kr gas strongly depends on the chemical composition of the materials. The relaxation-weighted contrast in hp 83Kr MRI allows for the distinction between hydrophobic and hydrophilic surfaces. The feasibility of hp 83Kr MRI of airways is tested in canine lung tissue by using krypton gas with natural abundance isotopic distribution. Additionally, the influence of magnetic field strength and the presence of a breathable concentration of molecular oxygen on longitudinal relaxation are investigated.

  10. Absorption process for removing krypton from the off-gas of an LMFBR fuel reprocessing plant

    International Nuclear Information System (INIS)

    Stephenson, M.J.; Dunthorn, D.I.; Reed, W.D.; Pashley, J.H.

    1975-01-01

    The Oak Ridge Gaseous Diffusion Plant selective absorption process for the collection and recovery of krypton and xenon is being further developed to demonstrate, on a pilot scale, a fluorocarbon-based process for removing krypton from the off-gas of an LMFBR fuel reprocessing plant. The new ORGDP selective absorption pilot plant consists of a primary absorption-stripping operation and all peripheral equipment required for feed gas preparation, process solvent recovery, process solvent purification, and krypton product purification. The new plant is designed to achieve krypton decontamination factors in excess of 10 3 with product concentration factors greater than 10 4 while processing a feed gas containing typical quantities of common reprocessing plant off-gas impurities, including oxygen, carbon dioxide, nitrogen oxides, water, xenon, iodine, and methyl iodide. Installation and shakedown of the facility were completed and some short-term tests were conducted early this year. The first operating campaign using a simulated reprocessing plant off-gas feed is now underway. The current program objective is to demonstrate continuous process operability and performance for extended periods of time while processing the simulated ''dirty'' feed. This year's activity will be devoted to routine off-gas processing with little or no deliberate system perturbations. Future work will involve the study of the system behavior under feed perturbations and various plant disturbances. (U.S.)

  11. Demonstration of a bronchopleural communication by inhalation of Kr-81m gas

    International Nuclear Information System (INIS)

    Vincken, W.; Schandevyl, W.; Sonstabo, R.; Bossuyt, A.

    1981-01-01

    Suspicion of a persisting communication between the bronchial tree and the pleural space in a patient with surgically drained pneumothorax was confirmed by the inhalation of Kr-81m gas. Compared to other diagnostic methods, this technique is harmless and repeatable, and hence very convenient for the assessment and follow-up of persisting pneumothorax due to air-leaks and of bronchopleural fistulas of any cause

  12. Optimization of krypton yields for rp-process studies at ISOLDE (CERN)

    CERN Document Server

    Kankainen, Anu Kristiina; Fraile-Prieto, L M; Jokinen, A; Leitner, M S; Oinonen, M; Peräjärvi, K; Ravn, H L

    2004-01-01

    The production of neutron-deficient krypton isotopes having astrophysical importance has been studied at the ISOLDE PBS facility at CERN. To investigate several effects on the yield a Monte Carlo code has been extensively applied.

  13. Evaluating the pacemaker effect with the pump parameter of gated blood-pool imaging

    International Nuclear Information System (INIS)

    Cheng Muhua

    1995-01-01

    13 normal controls and 27 patients with ventricular pacemaker had undergone planar gated blood-pool imaging in different conditions. Result shows: (1) Pump parameters can successfully reflect therapeutic effect of pacemaker among them EMP is the most valuable parameter for evaluating the cardiac pumping effect. (2) After implantation of the ventricular pacemaker, the LVEF did not increase, but the CO and EMP was significantly increased. (3) Compared with right ventricular demand pacemaker, the rate-responsive ventricular pacemaker give better hemodynamic benefit at exercise condition. (4) Through restrained cardiac pacemaker the functional change was analyzed on or off pace, and monitoring the cardiac function itself after the pacemaker was implanted

  14. Labeling of red blood cells with Tc-99m after oral administration of SnCl2. Concise communication

    International Nuclear Information System (INIS)

    Patel, M.C.; Parab, P.B.; Samuel, A.M.; Ganatra, R.D.

    1979-01-01

    In vivo labeling of red blood cells with Tc-99m was possible after prior oral administration of SnCl 2 , both in rats and human volunteers. Absorption of oral SnCl 2 was low but sufficient for more than 95% labeling efficiency. Prior i.v. administration of stannous chloride is known to induce in vivo labeling of red blood cells with pertechnetate. We have observed that such labeling is possible even after oral administration of stannous chloide. Nearly 95% of the circulating radioactivity and 93.7% of the administered radioactivity was in RBCs 30 min after i.v. injection of /sup 99m/TcO 4 - in rats that were fed 5 mg of stannous chloride (3.13 mg Sn 2+ ion) 2 hr before injection. Red blood cells from four human volunteers could bind pertechnetate, both in vitro and in vivo, after oral administration of 100 mg of SnCl 2 . We have obtained a blood-pool image of the human heart by labeling the RBCs in vivo by this method. We have also studied various parameters affecting the in vivo binding of RBCs with Tc-99m - such as the amount of orally administered SnCl 2 , the time of injection of radionuclide after oral SnCl 2 , and the optimum time for the imaging

  15. Production, quality control and initial imaging studies of [82mRb]RbCl for PET studies

    International Nuclear Information System (INIS)

    Rowshanfarzad, P.; Jalilian, A.R.; Kiyomarsi, M.; Sabet, M.; Karimian, A.R.; Moradkhani, S.; Mirzaii, M.

    2006-01-01

    Rubidium-82m was prepared via 15.4 MeV proton irradiation of a krypton-82 gaseous target (30% enrichment). Washing the target chamber with hot water yielded a Rb-82m containing solution, which was further purified using short column chromatography in order to remove organic/inorganic impurities. The flowthrough was formulated in normal saline for injection. Radionuclide, radiochemical and chemical purity tests were performed prior to administration to rats for imaging (radiochemical yield: 95-97%, radiochemical purity > 97%). Preliminary dual-head coincidence studies were performed to determine the distribution of [ 82m Rb]Rb in normal rats. For biodistribution studies, Rb-81 was injected to rats and tracer accumulation in heart, GI and bladder was determined after sacrification in time intervals. A yield of 1.3 GBq at EOB, 235.7 MBq/μAh was obtained. (authors)

  16. Excitation mechanisms in singly ionized krypton laser

    International Nuclear Information System (INIS)

    El-Sherbini, Th.M.

    1982-01-01

    Lifetimes for the low lying 4p 4 4d and 4p 4 5s levels of singly ionized krypton laser are calculated, taking into account configuration interaction effects. The results show that some of these levels are metastable. They also suggest a two step excitation from the ground state of the ion (or the atom) to the upper 4p 4 5p laser levels involving some intermediate metastable states as a possible excitation mechanism. (author)

  17. Electron impact excitation of autoionising states of krypton

    Science.gov (United States)

    Srivastava, S. K.; Trajmar, S.

    1978-01-01

    Energy-loss spectra of krypton in the region between 21 and 29 eV have been obtained at electron impact energies of 30, 60 and 100 eV. For each energy, the angular distribution of intensities has been measured at 5, 10 and 15 deg scattering angles. Assignments of spectral features found in this region are suggested and a comparison is made with previous measurements.

  18. Dating technique tested

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    An analytical technique for dating ground water and polar ice up to a million years old has been successfully tested by scientists at Oak Ridge National Laboratory (ORNL). The system, known as a rare gas atom counter, extends the capabilities of resonance ionization mass spectrometry to include counting single atoms of krypton-81. The counter is composed of a pulsed dye laser operated in tandem with a mass spectrometer to separate the various isotopes of krypton. In a collaborative study, ORNL scientists recently used the method for the first time to count krypton-81 in a liter of ground water removed from a sandstone aquifer near Zurich. Fewer than 1000 krypton-81 atoms were isolated from the ground water samples. According to Bernard Lehman, a collaborating geochemist at the University of Bern, this first test proved that counting the small numbers of krypton-81 atoms necessary to make an estimate of the age of water could actually be done. Among the applications of this method, Lehman says, could be improved siting of locations for the disposal of radioactive wastes

  19. High spatial resolution magnetic resonance imaging of experimental cerebral venous thrombosis with a blood pool contrast agent

    International Nuclear Information System (INIS)

    Spuentrup, E.; Wiethoff, A.J.; Parsons, E.C.; Spangenberg, P.; Stracke, C.P.

    2010-01-01

    Purpose: The purpose of this study was to investigate the feasibility of clot visualization in small sinus and cortical veins with contrast enhanced MRA in a cerebral venous thrombosis animal model using a blood pool contrast agent, Gadofosveset, and high spatial resolution imaging. Material and methods: For induction of cerebral venous thrombosis a recently developed combined interventional and microsurgical model was used. Cerebral sinus and cortical vein thrombosis was induced in six pigs. Two further pigs died during the procedure. Standard structural, time-of-flight- and phase contrast-angiograms were followed by fast time resolved high resolution 3D MRA (4D MRA) and subsequent high spatial resolution 3D MRA in the equilibrium phase with and without addition of parallel imaging. Visualization of the clots using the different sequences was subjectively compared and contrast-to-noise ratio (CNR) was assessed. Results: In the remaining six animals the procedure and MR-imaging protocol including administration of Gadofosveset was successfully completed. The 3D high resolution MRA in the equilibrium phase without the addition of parallel imaging was superior to all the other applied MR measurement techniques in terms of visualization of the clots. Only applying this sequence bridging vein thromboses were also seen as a small filling defect with a high CNR of >18. Conclusion: Only the non-accelerated high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset allows for high-contrast visualization of very small clots in the cerebral sinus and cortical veins. Statement clinical impact: Detection of cortical vein thrombosis is of high clinical impact. Conventional MRI sequences often fail to visualize the clot. We could demonstrate that, in contrast to conventional sequences, with high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset very small clots in the cerebral sinus and

  20. Short wavelength laser calculations for electron pumping in neon-like krypton (Kr XXVII)

    Science.gov (United States)

    Feldman, U.; Bhatia, A. K.; Suckewer, S.

    1983-01-01

    Calculations of electron impact collision strengths and spontaneous radiative decay rates are made for neon-like krypton (Kr XXVII) for the 2s2 2p6, 2s2 2p5 3s, 2s2 2p5 3p, and 2s2 2p5 3d configurations. From these atomic data, the level populations as a function of the electron density are calculated at two temperatures, 1 x 10 to the 7th K and 3 x 10 to the 7th K. An analysis of level populations reveals that a volume of krypton in which a significant number of the ions are in the Kr XXVII degree of ionization can produce a significant gain in transition between the 2s2 2p5 3s and 2s2 2p5 3p configurations. At an electron density of 1 x 10 to the 19th/cu cm the plasma length has to be of the order of 1 m; at a density of 1 x 10 to the 21st/cu cm the length is reduced to approximately 0.5 cm; and at an electron density of 1 x 10 to the 22nd/cu cm the length of the plasma is further reduced to approximately 1 mm.

  1. Generation of Multicharged Krypton Ions in Nanosecond Laser Ionization of Krypton Beam%纳秒激光电离产生Kr17+的研究

    Institute of Scientific and Technical Information of China (English)

    罗晓琳; 孔祥蕾; 牛冬梅; 渠洪波; 李海洋

    2004-01-01

    Up to Kr17+ muhicharged krypton ions have been observed in time-of-flight mass spectrum by a 25 ns Nd-YAG 1. 064 μm laser at laser intensity about 1012 W/cm2. Experimental results indicate that the muhicharged ions appear only when the laser interacts with the middle part of the pulsed beam, and the intensities of the multi charged ions increase dramatically by increasing the backing pressure of Kr gas, which indicates that the clusters in the beam is essential to the production of muhicharged ions. From the experimental results, it is concluded that the cluster is ionized via multiphoton ionization and forms a nanoplasma ball, which can absorb the laser resonantly to further ionize the single charge ion to the high charge state.

  2. The dielectronic satellites to the 2s-3p Ne-like krypton resonance lines

    International Nuclear Information System (INIS)

    Khakhalin, S.Ya.; Dyakin, V.M.; Faenov, A.Ya.; Fiedorowicz, H.; Bartnik, A.; Parys, P.; Nilsen, J.; Osterheld, A.

    1994-01-01

    We present an analysis of dielectronic satellite spectra of 2p 6 -2s2p 6 3p Ne-like krypton resonance lines. The satellite structure was registered with high (better than λ/Δλ > 3500) spectral resolution in the emission of a laser irradiated gas puff target. We perform an unambiguous identification of satellite lines caused by radiative transitions from autoionizing states of sodium-like krypton ions. A total of about 20 spectral features are identified, most of them for the first time. Very good agreement between the satellite structure calculations and experimental emission spectra is obtained. (orig.)

  3. The dielectronic satellites to the 2s-3p Ne-like krypton resonance lines

    Energy Technology Data Exchange (ETDEWEB)

    Khakhalin, S.Ya. (MISDC, NPO ' ' VNIIFTRI' ' , Mendeleevo (Russian Federation)); Dyakin, V.M. (MISDC, NPO ' ' VNIIFTRI' ' , Mendeleevo (Russian Federation)); Faenov, A.Ya. (MISDC, NPO ' ' VNIIFTRI' ' , Mendeleevo (Russian Federation)); Fiedorowicz, H. (Inst. of Optoelectronics, Warsaw (Poland)); Bartnik, A. (Inst. of Optoelectronics, Warsaw (Poland)); Parys, P. (Inst. of Plasma Physics and Laser Microfusion, Warsaw (Poland)); Nilsen, J. (Lawrence Livermore National Lab., Livermore, CA (United States)); Osterheld, A. (Lawrence Livermore National Lab., Livermore, CA (United States))

    1994-08-01

    We present an analysis of dielectronic satellite spectra of 2p[sup 6]-2s2p[sup 6]3p Ne-like krypton resonance lines. The satellite structure was registered with high (better than [lambda]/[Delta][lambda] > 3500) spectral resolution in the emission of a laser irradiated gas puff target. We perform an unambiguous identification of satellite lines caused by radiative transitions from autoionizing states of sodium-like krypton ions. A total of about 20 spectral features are identified, most of them for the first time. Very good agreement between the satellite structure calculations and experimental emission spectra is obtained. (orig.).

  4. Electromagnetic calorimeter on liquid krypton

    International Nuclear Information System (INIS)

    Bazzotti, M.; Bianco, G.L.; Lanni, F.; Maggi, B.; Palombo, F.; Sala, A.

    1990-01-01

    This paper reports on use of noble condensed gases as calorimeter media that is attractive due to the possibility to get not only good energy resolution (like in NaI and CsI calorimeters) but better space resolution for photons. Longitudinal segmentation can provide information for particle identification by dE/dx and also e/π-separation based on longitudinal structure of the shower. The best material for this aim is of course liquid Zenon, but it is impossible to get the necessary amount of it in reasonable time. Therefore, the authors have stopped their choice on the next candidate-liquid Krypton (LKr). Its sufficient amount can be obtained before to the beginning of the experiment

  5. Muonium localization in solid krypton

    International Nuclear Information System (INIS)

    Storchak, V.; Cox, S.F.J.; Brewer, J.H.; Morris, G.D.

    1995-06-01

    Muonium spin relaxation in zero, longitudinal and transverse magnetic fields has been studied in solid and liquid krypton in the temperature range from 2 K to 120 K. In the solid at low temperatures, the spin dynamics exhibit features characteristic of a magnetically dilute crystal, permitting measurements of exceptionally low muonium diffusion rates. At the lowest temperatures, a static Kubo-Toyabe relaxation function has been observed for the first time for the atomic muonium state, indicating strong interstitial localization in the Kr lattice at low temperatures; muonium is determined to be localized at the tetrahedral interstitial position. At high temperatures, muonium diffusion in solid Kr exhibits a non-classical behaviour. (author). 31 refs., 6 figs

  6. Effective and accurate approach for modeling of commensurate-incommensurate transition in krypton monolayer on graphite.

    Science.gov (United States)

    Ustinov, E A

    2014-10-07

    Commensurate-incommensurate (C-IC) transition of krypton molecular layer on graphite received much attention in recent decades in theoretical and experimental researches. However, there still exists a possibility of generalization of the phenomenon from thermodynamic viewpoint on the basis of accurate molecular simulation. Recently, a new technique was developed for analysis of two-dimensional (2D) phase transitions in systems involving a crystalline phase, which is based on accounting for the effect of temperature and the chemical potential on the lattice constant of the 2D layer using the Gibbs-Duhem equation [E. A. Ustinov, J. Chem. Phys. 140, 074706 (2014)]. The technique has allowed for determination of phase diagrams of 2D argon layers on the uniform surface and in slit pores. This paper extends the developed methodology on systems accounting for the periodic modulation of the substrate potential. The main advantage of the developed approach is that it provides highly accurate evaluation of the chemical potential of crystalline layers, which allows reliable determination of temperature and other parameters of various 2D phase transitions. Applicability of the methodology is demonstrated on the krypton-graphite system. Analysis of phase diagram of the krypton molecular layer, thermodynamic functions of coexisting phases, and a method of prediction of adsorption isotherms is considered accounting for a compression of the graphite due to the krypton-carbon interaction. The temperature and heat of C-IC transition has been reliably determined for the gas-solid and solid-solid system.

  7. Spiral arm amplitude variations and pattern speeds in the grand design galaxies M51, M81, and M100

    International Nuclear Information System (INIS)

    Elmegreen, B.G.; Seiden, P.E.; Elmegreen, D.M.

    1989-01-01

    In the modal theory of galactic spiral structure, the amplitude of a prominent two-arm spiral pattern should oscillate slightly with galactocentric distance because of an interference between the outward and inward propagating waves. In the stellar dynamical theory, the spiral arm amplitudes should oscillate because of differential crowding near and between wave-orbit resonances. Two and three cycles of such oscillations have been found in computer-enhanced images at B and I passbands of the grand design galaxies M81 and M100, respectively, and what is probably one cycle of such an amplitude variation in M51. These three galaxies are the most symmetric and global of the two-arm spirals in the near-IR survey of Elmegreen (1981), so the occurrence of such spiral amplitude oscillations could be common among galaxies of this type. The positions of the features discussed are used to suggest possible arm pattern speeds. 23 refs

  8. Monitoring and assay procedures for krypton-85 used in circulatory tests

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Jr., J. M.; Williams, K. D.

    1963-11-15

    During the past five years, krypton-85 has been used extensively at the National Institutes of health and by the heart Catheterization laboratory in the identification of circulatory shunts. Several methods of assaying the incoming shipments of radioactive gas are given. These consist of ionization chamber measurements, gamma ray spectrometry, and gross photon counting of the cylinder surface with an end-window Geiger-Mueller tube. A device (consisting of a log-count-rate meter, recorder, and G.M. tube) is used to continuously monitor the laboratory. The method of calibrating this device is presented. A means for removing contaminated air from the vicinity of the operating table was devised. The results of air clearance studies of the room are included. (auth)

  9. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. II. Citric, tartaric, undecylenic acids

    Energy Technology Data Exchange (ETDEWEB)

    Harangozo, M.; Jombik, J.; Schiller, P. (Komenskeho Univ., Bratislava (Czechoslovakia). Farmaceuticka Fakulta); Toelgyessy, J. (Slovenska Vysoka Skola Technicka, Bratislava (Czechoslovakia). Chemickotechnologicka Fakulta)

    1981-01-01

    A method for the determination of citric, tartaric and undecylenic acids based on radiometric titration with 0.1 or 0.05 mole.l/sup -1/ NaOH was developed. As an indicator of the end point, radioactive kryptonate of glass was used. Experimental technique, results of determinations as well as other possible applications of the radioactive kryptonate of glass for end point determination in alkalimetric analyses of officinal pharmaceuticals are discussed.

  10. Effect of hydration on the organo-noble gas molecule HKrCCH: role of krypton in the stabilization of hydrated HKrCCH complexes.

    Science.gov (United States)

    Biswas, Biswajit; Singh, Prashant Chandra

    2015-11-11

    The effect of hydration on the fluorine free organo-noble gas compound HKrCCH and the role of krypton in the stabilization of the hydrated HKrCCH complexes have been investigated using the quantum chemical calculations on the HKrCCH-(H2O)n=1-6 clusters. Structure and energetics calculations show that water stabilizes HKrCCH through the π hydrogen bond in which the OH group of water interacts with the C[triple bond, length as m-dash]C group of HKrCCH. A maximum of four water molecules can directly interact with the C[triple bond, length as m-dash]C of HKrCCH and after that only inter-hydrogen bonding takes place between the water molecules indicating that the primary hydration shell contains four water molecules. Atom in molecule analysis depicts that π hydrogen bonded complexes of the hydrated HKrCCH are cyclic structures in which the OKr interaction cooperates in the formation of strong O-HC[triple bond, length as m-dash]C interaction. Structure, energetics and charge analysis clearly established that krypton plays an important role in the stabilization as well as the formation of the primary hydration shell of hydrated HKrCCH complexes.

  11. Monitoring of air pollutants and greenhouse gases. Monitoring Krypton-85

    International Nuclear Information System (INIS)

    Novitchkov, V.

    1996-01-01

    Krypton-85 is an anthropogenic radioactive noble gas, a gaseous fission product which builds up in the atmosphere. The World Meteorological Organization (WMO) Global Atmospheric Watch (GAW) integrates many monitoring and research activities involving the measurements of atmospheric composition. Kr-85 represents one of the gases recommended by the WMO for monitoring. The collaborative program of the Moscow State Engineering Physics Institute (MEPI) and the US Air Resources Laboratory (ARL) NOAA activities is aimed at determining the possible future consequences of Krypton-85 content (trend) increasing in the earth's atmosphere. The research is conducted at the MEPI to study the character of KR-85 release into the atmosphere and its distribution in the atmosphere, to determine Kr-85 possible sources. If only the question of the direct impact of Kr-85 on climate would be considered, only the order of magnitude of the atmospheric concentration would be of interest. In this case almost any available detection method and a precision as low as some 10% would be acceptable. If however, Kr-85 is to be applied as a tracer for the improvement of our present knowledge of local, regional and global transport and mixing processes and the validation of global-scale transport and mixing models, a much higher precision is required (order of +1%). This high standard cannot be met without a permanent quality assurance programmer. It is within the framework of the WMO that MEPI and the Air Resources Laboratory NOAA USA proposes collaboration of Kr-85 scientific findings. The project MEPI open-quotes Monitoring Krypton-85close quotes is being financed through the International Science and Technology Center

  12. Assessment of bronchial provocation by sup(81m)Kr ventilation image in asthmatic children

    International Nuclear Information System (INIS)

    Sugimoto, Kazuo; Toba, Tsuyoshi; Uchiyama, Guio; Arimizu, Noboru.

    1982-01-01

    Allergen- or mediator-induced bronchospasm was studied by sup(81m)Kr ventilation image to determine it's sensitivity and safety as an assessment method. Twelve children with house dust sensitive asthma were subjected to inhalation of house dust, prostaglandin F sub(2α), or methacholine by ultrasonic nebulizer with sup(81m)Kr gas. During the examination dynamic ventilation images of both lungs were monitored on oscilloscope to see the changes in the ventilation images. This kind of provocation test has the following advantages compared to the conventional provocation tests. 1) There is no induction of severe attack by provocation when inhalation of antigen of mediator is stopped at the initiation of change on the ventilation image. 2) There is no overload to the patient as compared to the conventional provocation tests. 3) Analysis of the ventilation images stored in the computer can reveal the area of ventilation disturbance in the lung and the changes can be expressed quantitatively. (author)

  13. Steady state operation of the first cryogenic column in a krypton separation system

    International Nuclear Information System (INIS)

    von Ammon, R.; Bumiller, W.; Hutter, E.; Neffe, G.

    1981-01-01

    Recent results obtained during the operation of the inactive test unit KRETA for the cryogenic separation of krypton from simulated reprocessing off-gases are presented. The first rectification column of this unit was modified by shortening its lower part from 18 to 8 practical plates and placing the feed point into the warmer, krypton-rich section. Two essential results were thus achieved: plugging by desubliming xenon was not observed even at xenon feed concentrations as high as 1 vol.-%; and, accumulation of oxygen was much lower than in the column version used previously, thus reducing the potential hazard by ozone formation drastically. The accumulation of methane, however, was found to be high, in agreement with calculations

  14. Method of determining paper-deposited materials, eg. lead, by their reaction with radioactive krypton

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Pruzinec, J.

    1976-01-01

    The invention claims a method of determining substances on a paper carrier based on the substance reaction with 85 Kr gas and the measurement of radioactivity of the kryptonate formed. Lead is shown as an example. Different amounts of lead acetate were deposited on Whatman 2 chromatographic paper as was an unknown sample of Pb salt. The paper was exposed to a 2.5 mCi 85 Kr atmosphere for 48 hours. The activity of the individual spots was then measured, a calibration curve established and the amount of lead in the analyzed sample read-out. (Ha)

  15. The mRNA level of MLH1 in peripheral blood is a biomarker for the diagnosis of hereditary nonpolyposis colorectal cancer.

    Science.gov (United States)

    Yu, Hong; Li, Hui; Cui, Yongan; Xiao, Wei; Dai, Guihong; Huang, Junxing; Wang, Chaofu

    2016-01-01

    Hereditary nonpolyposis colorectal cancer (HNPCC) is caused by functional defects in mismatch repair (MMR) genes, including mutL homolog 1 (MLH1) and mutS homolog 2 (MSH2). This study aimed to assess whether the mRNA expression of MLH1 in peripheral blood could be used as a biomarkers for the diagnosis of HNPCC. The mRNA level of MLH1 was determined in 19 HNPCC families (46 members) using real-time quantitative polymerase chain reaction (qPCR). The mRNA levels of MLH1 in HNPCC were significantly lower than controls (P MLH1 for the diagnosis of HNPCC with the area under curve of 0.858. At an optimal cut-off value (0.511), the mRNA level of MLH1 had a sensitivity of 81.3% and a specificity of 86.7% for distinguishing HNPCC from controls. In conclusion, the mRNA expression of MLH1 in peripheral blood may serve as a biomarker for the diagnosis of HNPCC.

  16. Separation of the fission product noble gases krypton and xenon from dissolver off-gas in reprocessing HTGR-fuel

    International Nuclear Information System (INIS)

    Bohnenstingl, J.; Djoa, S.H.; Laser, M.; Mastera, S.; Merz, E.; Morschl, P.

    1976-01-01

    This paper describes a process developed for the retainment and separation of volatile ( 3 H, 129+131 I) and gaseous ( 85 Kr, Xe) fission products from the off-gas produced during dissolution of HTGR-fuel. To prevent unnecessary dilution of liberated noble gases by surrounding atmosphere, a helium purge-gas cycle is applied to enable a coarse fractionating of krypton and xenon by cold-trapping at about 80 0 K after precleaning the gas stream. The process consists of the following steps: deposition of droplets and solid aerosols; chemisorption of iodine on silver impregnated silica gel; catalytic removal of nitrogen oxides and oxygen; drying of the process gas stream; final filtering of abraded solids; deposition of xenon in solid form at 80 0 K and low subpressure; deposition of krypton in solid form at 80 0 K after compression to about 6 bar; decontamination of 85 Kr-containing xenon by batch distillation for eventual industrial utilization; and removal of nitrogen and argon enrichment during continuous operation in the purge-gas stream by inleaking air with charcoal. A continuously operating dissolver vessel, closed to the surrounding atmosphere, yields a very high content of noble gases, i.e., 0.35 vol % krypton and 2.0 vol % xenon. The presented off-gas treatment unit is operated in cold runs with 1 / 3 of the full capacity and can treat about 1 m 3 STP/h helium, corresponding to a quantity of about 10,000 MW/sub e/ HTGR-fuel reprocessing plant

  17. Recovery of krypton-85 from dissolver off-gas streams

    International Nuclear Information System (INIS)

    Law, J.P.; Lamb, K.M.

    1988-01-01

    The Rare Gas Plant at the Idaho Chemical Processing Plant Recovers fission product krypton and xenon from dissolver off gas streams. Recently the system was upgraded to allow processing of hydrogen rich dissolver off-gas streams. A trickle bed hydrogen recombiner was installed and tested. The Rare Gas Plant can now safely process gas streams containing up to 80% hydrogen

  18. Removing krypton from xenon by cryogenic distillation to the ppq level

    Science.gov (United States)

    Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Duchovni, E.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Franco, D.; Fulgione, W.; Gallo Rosso, A.; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Huhmann, C.; Itay, R.; Kaminsky, B.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Calloch, M. Le; Lin, Q.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Meng, Y.; Messina, M.; Micheneau, K.; Miguez, B.; Molinario, A.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Orrigo, S. E. A.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Piro, M.-C.; Pizzella, V.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Saldanha, R.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Upole, N.; Wang, H.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhang, Y.; Cristescu, I.

    2017-05-01

    The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β -emitter ^{85}Kr which is present in the xenon. For XENON1T a concentration of natural krypton in xenon ^{nat}Kr/Xe McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4\\cdot 10^5 with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of ^{nat}Kr/Xe<26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.

  19. Photocoagulation of disciform macular lesions with krypton laser.

    Science.gov (United States)

    Bird, A C; Grey, R H

    1979-01-01

    Ten vascular disciform mucular lesions were treated by krypton laser photocoagulation. In 8 the lesion resolved after therapy, and in 7 the retina remained flat for 6 months. On those patients treated successfully 6 had a visual acuity of 6/12 or better. The morphology of the laser lesion differed from that of the argon lesion in that there is no evidence of thermal coagulation of the inner retina near the foveola. Images PMID:574396

  20. Detection of occult pericardial hemorrhage early after open-heart surgery using technetium-99m red blood cell radionuclide ventriculography

    International Nuclear Information System (INIS)

    Bateman, T.M.; Czer, L.S.; Gray, R.J.; Kass, R.M.; Raymond, M.J.; Garcia, E.V.; Chaux, A.; Matloff, J.M.; Berman, D.S.

    1984-01-01

    Pericardial or mediastinal hemorrhage requiring reoperation occurs in 2% to 5% of patients, usually early (0 to 48 hours), after open-heart surgery. This hemorrhage may be occult, and resulting cardiac tamponade may easily be misinterpreted as ventricular dysfunction, common early postoperatively. In such cases, appropriate and timely intervention may not occur. Of 50 patients evaluated by technetium-99m red blood cell gated equilibrium radionuclide ventriculography (RNV) because of early postoperative cardiogenic shock of uncertain etiology, 17 had unique scintigraphic images suggestive of intrathoracic hemorrhage. Of these 17, 5 had a generalized halo of abnormal radioactivity surrounding small hyperdynamic right and left ventricles, 11 had localized regions of intense blood pool activity outside the cardiac chambers (two with compression of single chambers), and one demonstrated marked radionuclide activity in the right hemithorax (2000 ml of blood at reoperation). Twelve patients had exploratory reoperation for control of hemorrhage as a direct result of the scintigraphic findings, three were successfully treated with fresh frozen plasma and platelet infusions along with medical interventions to optimize cardiac performance, and two patients died in cardiogenic shock (presumed tamponade) without reoperation. In the 12 reoperated patients, all were confirmed to have active pericardial bleeding. Scintigraphic localization of abnormal blood pools within the pericardium corresponded to the sites at which active bleeding was witnessed at reoperation. The abnormal bleeding was etiologically related to the tamponade state, with marked improvement in hemodynamics after reoperation. Nine additional patients were reoperated for presumed tamponade after RNV revealed an exaggerated halo of photon deficiency surrounding the cardiac chambers

  1. Quantitative assessment of limb blood flow using Tc-99m labeled red blood cells

    International Nuclear Information System (INIS)

    Itoh, Kazuo; Shougase, Takashi; Kawamura, Naoyuki; Tsukamoto, Eriko; Nakada, Kunihiro; Sakuma, Makoto; Furudate, Masayori

    1987-01-01

    A quantitative assessment of limb blood flow using a non-diffusible radioindicator, Tc-99m labeled red blood cells, was reported. This was an application of venous occlusion plethysmography using radionuclide which was originally proposed by M. Fukuoka et al. The peripheral blood flow (mean ± s.e.) of 30 legs in a normal control group was 1.87 ± 0.08 ml/100 ml/min. In heart diseases (46 legs), it was 1.49 ± 0.13 ml/100 ml/min. The limb blood flow between a control group and heart diseases was statistically significant (p < 0.01) in the t-test. The peripheral blood flow at rest between diseased legs and normal legs in occlusive arterial disorders was also statistically significant (p < 0.01) in a paired t-test. RAVOP was done after the completion of objective studies such as radionuclide angiography or ventriculography. Technique and calculation of a blood flow were very easy and simple. RAVOP study which was originally proposed by Fukuoka et al. was reappraised to be hopeful for quantitative measurement of limb blood flow as a non-invasive technique using Tc-99m labeled red blood cells. (author)

  2. Semi-automatic segmentation of gated blood pool emission tomographic images by watersheds: application to the determination of right and left ejection fractions

    International Nuclear Information System (INIS)

    Mariano-Goulart, D.; Collet, H.; Kotzki, P.-O.; Zanca, M.; Rossi, M.

    1998-01-01

    Tomographic multi-gated blood pool scintigraphy (TMUGA) is a widely available method which permits simultaneous assessment of right and left ventricular ejection fractions. However, the widespread clinical use of this technique is impeded by the lack of segmentation methods dedicated to an automatic analysis of ventricular activities. In this study we evaluated how a watershed algorithm succeeds in providing semi-automatic segmentation of ventricular activities in order to measure right and left ejection fractions by TMUGA. The left ejection fractions of 30 patients were evaluated both with TMUGA and with planar multi-gated blood pool scintigraphy (PMUGA). Likewise, the right ejection fractions of 25 patients were evaluated with first-pass scintigraphy (FP) and with TMUGA. The watershed algorithm was applied to the reconstructed slices in order to group together the voxels whose activity came from one specific cardiac cavity. First, the results of the watershed algorithm were compared with manual drawing around left and right ventricles. Left ejection fractions evaluated by TMUGA with the watershed procedure were not significantly different (p=0.30) from manual outlines whereas a small but significant difference was found for right ejection fractions (p=0.004). Then right and left ejection fractions evaluated by TMUGA (with the semi-automatic segmentation procedure) were compared with the results obtained by FP or PMUGA. Left ventricular ejection fractions evaluated by TMUGA showed an excellent correlation with those evaluated by PMUGA (r=0.93; SEE=5.93%; slope=0.99; intercept = 4.17%). The measurements of these ejection fractions were significantly higher with TMUGA than with PMUGA (P<0.01). The interoperator variability for the measurement of left ejection fractions by TMUGA was 4.6%. Right ventricular ejection fractions evaluated by TMUGA showed a good correlation with those evaluated by FP (r = 0.81; SEE = 6.68%; slope = 1.00; intercept = 0.85%) and were not

  3. Design and construction of a cryogenic distillation device for removal of krypton for liquid xenon dark matter detectors.

    Science.gov (United States)

    Wang, Zhou; Bao, Lei; Hao, Xihuan; Ju, Yonglin

    2014-01-01

    Liquid xenon (Xe) is one of the commendable detecting media for the dark matter detections. However, the small content of radioactive krypton-85 ((85)Kr) always exists in the commercial xenon products. An efficient cryogenic distillation system to remove this krypton (Kr) from commercial xenon products has been specifically designed, developed, and constructed in order to meet the requirements of the dark matter experiments with high- sensitivity and low-background. The content of krypton in regular commercial xenon products can be reduced from 10(-9) to 10(-12), with 99% xenon collection efficiency at maximum flow rate of 5 kg/h (15SLPM). The purified xenon gases produced by this distillation system can be used as the detecting media in the project of Panda X, which is the first dark matter detector developed in China.

  4. Particle simulation of grid system for krypton ion thrusters

    Directory of Open Access Journals (Sweden)

    Maolin CHEN

    2018-04-01

    Full Text Available The transport processes of plasmas in grid systems of krypton (Kr ion thrusters at different acceleration voltages were simulated with a 3D-PIC model, and the result was compared with xenon (Xe ion thrusters. The variation of the screen grid transparency, the accelerator grid current ratio and the divergence loss were explored. It is found that the screen grid transparency increases with the acceleration voltage and decreases with the beam current, while the accelerator grid current ratio and divergence loss decrease first and then increase with the beam current. This result is the same with Xe ion thrusters. Simulation results also show that Kr ion thrusters have more advantages than Xe ion thrusters, such as higher screen grid transparency, smaller accelerator grid current ratio, larger cut-off current threshold, and better divergence loss characteristic. These advantages mean that Kr ion thrusters have the ability of operating in a wide range of current. Through comprehensive analyses, it can be concluded that using Kr as propellant is very suitable for a multi-mode ion thruster design. Keywords: Grid system, Ion thrusters, Krypton, Particle in cell method, Plasma

  5. Design for a Remote Monitoring Equipment of Krypton-85

    Institute of Scientific and Technical Information of China (English)

    LUXue-sheng; LIUGuo-rong; YEFeng; JINHui-min; TANGPei-jia

    2003-01-01

    A prototype equipment for monitoring Krypton-85 in situ is designed and set up. A series of relevant software is also developed for remote control, data acquirement and data analysis. Weight of the system is about 300 kg, which is composed of NaI(T1) detector, digi DART, Marillin measurement container and lead shield. The whole system is placed on a homemade go-cart.

  6. All-optical atom trap trace analysis for rare krypton isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Woelk, Pablo; Kohler, Markus; Sieveke, Carsten; Hebel, Simon; Sahling, Peter [Carl Friedrich von Weizsaecker Centre for Science and Peace Research, University of Hamburg (Germany); Becker, Christoph; Sengstock, Klaus [Institut fuer Laser-Physik, University of Hamburg (Germany)

    2016-07-01

    The isotope Krypton-85 is an excellent indicator for the detection of nuclear reprocessing activities. However, for the analysis of atmospheric air samples, sensitive measuring methods down to the single atom level are required because of the small concentrations. Furthermore, for a practical and effective detection of clandestine reprocessing, small sample sizes and a high sample throughput rate are desirable. Established methods using Atom Trap Trace Analysis (ATTA) allow high sensitivity but have a limited throughput of about 200 samples per year, since the vacuum chambers have to be flushed for several hours after each measurement to avoid cross contamination due to the RF-driven excitation of metastable states. Here we present an enhanced ATTA apparatus, which in contrast to the established methods, produces metastable Kr all-optically. This avoids cross contamination, therefore allowing a much higher throughput rate. The apparatus is based on a self-made VUV-lamp and a 2D-3D magneto-optical trap setup. In the 2D trap metastable krypton is produced and a beam of atoms is formed by Doppler-cooling simultaneously.

  7. Study of krypton laser-induced choroidal neovascularization in a Guinea pig model of high anisometropia.

    Science.gov (United States)

    Wang, Jianghui; Jiang, Wei; Kang, Zefeng; Liang, Lina; Liu, Xiaoman; Tian, Nannan; Zhang, Qing

    2012-06-01

    To investigate the association between high anisometropia and the area of choroidal neovascularization (CNV) induced by krypton laser in guinea pigs and better understand the pathogenesis and prevention of myopic CNV. Nine 3-week old male guinea pigs with anisometropia >6.00D were randomly assigned to three groups according to examination date after laser photocoagulation (7d, 14d and 28d). All animals underwent refraction. The eye with higher myopia was used as the experimental eye, and the other as the control eye. All eyes received repeated multi-wavelength krypton laser photocoagulation treatments (wavelength: 532nm; laser power: 400mW; spot diameter: 50μm; exposure time: 0.1s). Fundus photography and indocyanine green angiography (ICGA) were performed. Afterwards, the animals were sacrificed immediately, and the eyes were enucleated and processed for histopathologic examination and flat mounts. CNV appeared at 7d after laser treatment. The area of CNV peaked at 14d, and decrease in area and the presence of scarring was noted at 28 d. CNV was present in 66.7% of eyes by ICGA at 14 d. CNV could be observed under light microscopy at all three time points. At 14d, flat mount showed the neovascular plexus around the lesion. Semi-quantitative analysis revealed that the area of CNV in treated eyes was greater than that of control eyes. Since the mechanism of CNV in this study resembles that of CNV in pathological myopia, this model can be used to investigate the etiology, pathogenesis and treatment of CNV in pathological myopia.

  8. Solar swimming pool

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    This report examines the feasibility of using solar collectors to heat the water in a previously unheated outdoor swimming pool. The solar system is used in conjunction with a pool blanket, to conserve heat when the pool is not in use. Energy losses through evaporation can be reduced by as much as 70% by a pool blanket. A total of 130 m{sup 2} of highly durable black synthetic collectors were installed on a support structure at a 30{degree} angle from the horizontal, oriented to the south. Circulation of pool water though the collectors, which is controlled by a differential thermostat, was done with the existing pool pump. Before installation the pool temperature averaged 16{degree}C; after installation it ranged from 20{degree} to 26{degree}C. It was hard to distinguish how much pool heating was due to the solar system and how much heat was retained by the pool blanket. However, the pool season was extended by five weeks and attendance tripled. 2 figs.

  9. L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Petkov, E. E., E-mail: emilp@unr.edu; Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V. [University of Nevada, Reno, Nevada 89557 (United States); Rawat, R. S.; Tan, K. S. [National Institute of Education, Nanyang Technological University, Singapore 637616 (Singapore); Beiersdorfer, P.; Brown, G. V. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, 96049 Bamberg (Germany)

    2016-11-15

    X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

  10. L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources.

    Science.gov (United States)

    Petkov, E E; Safronova, A S; Kantsyrev, V L; Shlyaptseva, V V; Rawat, R S; Tan, K S; Beiersdorfer, P; Hell, N; Brown, G V

    2016-11-01

    X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

  11. 直接进样气相色谱-质谱法分析大气中的氪和氙%Determination of Atmospheric Krypton and Xenon by Gas Chromatography-Mass Spectrometry in Direct Injection Mode

    Institute of Scientific and Technical Information of China (English)

    陈占营; 刘蜀疆; 王建龙; 常印忠

    2016-01-01

    Volume concentration determination for atmospheric krypton and xenon is very important for krypton-85 and radioactive xenon isotopes monitoring. An injection setup integrated adjustable quantity sample injection and quantitative dilution function was designed. The effects of EI source parameters on the sensitivity of MS detector were studied. The optimized values were as following: ionization energy of 70 eV, emission current of 40 mA, cathode voltage of 27 mV, focus voltage of 85 mV and lens compensation of 20 V, respectively. A GC-MS method for the determination of krypton and xenon in atmosphere without of sample pretreatment was developed. The minimal detected concentrations for krypton and xenon were 3. 3×10-8(V/V) and 2. 6×10-9(V/V). Moreover, the krypton and xenon concentrations in the ground level air around our laboratory were measured with the results of 1 . 1 × 10-6 ( V/V ) and 9 . 3 × 10-8 ( V/V ) . The related combined standard uncertainties for krypton and xenon results were 2. 38% and 3. 15%, respectively.%大气中氪和氙体积比浓度的测量对于氪-85和放射性氙同位素监测具有重要意义。本实验设计了一套集成定量稀释功能的可调样量进样装置,对质谱检测器的工作参数进行了实验优化,确定了灯丝电离能量70 eV、灯丝发射电流40 mA、推斥极电压27 mV、离子聚焦电压85 mV和透镜补偿电压20 V等最佳工作条件。建立了空气样品直接进样条件下氪和氙的气质联用分析方法,氪和氙的最低可检测浓度分别为3.3×10-8(V/V)和2.6×10-9(V/V)。同时应用本方法测量了实验室所处开放空间大气中氪和氙的体积比浓度,分别为1.1×10-6(V/V)和9.3×10-8(V/V),相对合成标准不确定度分别为2.38%和3.15%。

  12. Assessment of left ventricular function by gated cardiac blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru

    1991-01-01

    To elucidate the usefulness of gated cardiac blood-pool single photon emission CT (SPECT) with Tc-99m for the evaluation of left ventricular (LV) global and regional functions, 18 patients with coronary artery disease were studied. Thirty-two gated projection images were obtained over 360-degree at 16 frames per cardiac cycle. As LV volume was calculated by integrating the numbers of voxels which constituted LV and multiplying by the volume of a single voxel (0.1143 ml), we performed phantom studies to determine the appropriate cut-off level to detect LV outline. These cut-off levels were affected by the background activity and organ volume itself. So we constructed Volume-Cut-Level-Curve at each background activity. In clinical studies, short axis images which constituted LV were selected and provisional LV volumes were calculated at the cut-off levels of 45, 50 and 55%. These volumes were plotted on the Volume-Cut-Level-Curve and the true cut-off levels were obtained to calculate LV end-diastolic or end-systolic volume (EDV, ESV). The cut-off levels were different at every patient and ED or ES. EDV, ESV and LV ejection fraction obtained by SPECT were correlatd well with those obtained by contrast ventriculography (LVG) (r=0.89, 0.94, 0.94 each, p<0.01). For the LV wall motion analysis, LVGs obtained at two projections were compared with SPECT or gated cardiac blood-pool planar imaging (Planar) in 5 segments. In addition to visual comparison, wall motion scores (WMS) based on the degree of wall motion abnormality were calculated in each segment. Correlation of WMS between LVG and SPECT (r=0.84) was significantly (p<0.01) superior to that between LVG and Planar (r=0.62). Especially in SPECT, wall motion analyses at septal and infero-posterior segments were superior to those in Planar. Although gated SPECT requires relatively long time to perform, it is a useful method to detect LV global and regional functions. (author)

  13. Breast tumor targeting with 99mTc-HYNIC-PR81 complex as a new biologic radiopharmaceutical

    International Nuclear Information System (INIS)

    Salouti, Mojtaba; Rajabi, Hossein; Babaei, Mohammad Hossein; Rasaee, Mohammad Javad

    2008-01-01

    Human epithelial mucin, MUC1, is commonly overexpressed in adenocarcinoma that includes more than 80% of breast cancers. The PR81 is a murine anti-MUC1 monoclonal antibody (MAb) that was prepared against the human breast cancer. We developed an indirect method for labeling of this antibody with 99m Tc in order to use the new preparation in immunoscintigraphy studies of BALB/c mice bearing breast tumors. The 99m Tc-PR81 complex was prepared using the HYNIC as a chelator and tricine as a coligand. The labeling efficiency determined by instant thin-layer chromatography (ITLC) was 89.2%±4.7%, and radiocolloides measured by cellulose nitrate electrophoresis were 3.4%±0.9%. The in vitro stability of labeled product was determined at room temperature by ITLC and in human serum by gel filtration chromatography - 88.3%±4.6% and 79.8%±5.7% over 24 h, respectively. The integrity of labeled MAb was checked by means of sodium dodecyl sulfate polyacrylamide gel electrophoresis, and no significant fragmentation was seen. The results of cell binding studies showed that both labeled and unlabeled PR81 were able to compete for binding to MCF 7 cells. Biodistribution studies performed in female BALB/c mice with breast tumor xenografts at 4, 16 and 24 h after the 99m Tc-HYNIC-PR81 injection demonstrated a specific localization of the compound at the site of tumors and minimum accumulation in non target organs. The tumor imaging was performed in BALB/c mice with breast xenograft tumors at 4, 8, 12, 16, 20, 24, 28, 32 and 36 h after the complex injection. The tumors were visualized with high sensitivity after 8 h. The findings showed that the new radiopharmaceutical is a promising candidate for radioimmunoscintigraphy of the human breast cancer

  14. Resonance ionization spectroscopy of argon, krypton, and xenon using vacuum ultraviolet light

    International Nuclear Information System (INIS)

    Kramer, S.D.

    1984-04-01

    Resonant, single-photon excitation of ground state inert gases requires light in the vacuum ultraviolet spectral region. This paper discusses methods for generating this light. Efficient schemes for ionizing argon, krypton, and xenon using resonant, stepwise single-photon excitation are presented

  15. Parametric tomography of the cardiac blood pool

    International Nuclear Information System (INIS)

    Meyer, M.; Schwartz, K.D.

    1990-01-01

    In nuclear cardiology image processing is performed usually in 3 of 4 dimensions. ECG-gated SPECT (GSPECT) would make it possible to obtain all 4 dimensions of space and time during one examination, but its duration as well as radiation dose is limited resulting in a low signal-to-noise ratio. Sensitive feature extractions from the amount of data are necessary, e.g. Fourier filtering or extracting isovolumetric intervals. The relatively large amount of calculations and storage requirements often handicaps tomographic ventriculography because a high number of sections have to be processed and the temporal resolution is limited. A new list-mode oriented tomographic algorithm demands less storage and fewer calculations: The Fourier coefficient extraction and the filtered back projection, both of which are linear operations, could be interchanged in the case of thoracic SPECT. The feature extraction algorithm process internal list-mode heart cycles for discrimination of invalid cycles, for end-diastolic and end-systolic synthesis as well as for Fourier analysis of the first harmonic in 10 ms steps. Reconstruction operations are applied also to modified distribution matrices of Fourier coefficients. By only processing 4 spatial matrix sequences (end-diastolic and end-systolic images, amplitude and phase values) parametric tomography becomes practicable and could be also performed by a minicomputer with 64 KByte memory in addition to the possibilities of the planar left ventricular gated imaging. If there are 3 or more processors available a complete feature extraction on-the-fly will be possible. The numerical algorithms were tested with respect to stable reconstructions by phantoms. First results of a patient examination are used to explore effective display techniques, and preliminary modes are demonstrated. It is the purpose of this study to obtain additional information about the gated planar cardiac blood pool imaging in the field of SPECT. (author)

  16. Krypton K-shell X-ray spectra recorded by the HENEX spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Seely, J.F. [Naval Research Laboratory, Space Science Division, Washington DC 20375 (United States)]. E-mail: john.seely@nrl.navy.mil; Back, C.A. [Lawrence Livermore National Laboratory, Livermore CA 94550 (United States); Constantin, C. [Lawrence Livermore National Laboratory, Livermore CA 94550 (United States); Lee, R.W. [Lawrence Livermore National Laboratory, Livermore CA 94550 (United States); Chung, H.-K. [Lawrence Livermore National Laboratory, Livermore CA 94550 (United States); Hudson, L.T. [National Institute of Standards and Technology, Gaithersburg MD 20899 (United States); Szabo, C.I. [National Institute of Standards and Technology, Gaithersburg MD 20899 (United States); Henins, A. [National Institute of Standards and Technology, Gaithersburg MD 20899 (United States); Holland, G.E. [SFA Inc., 9315 Largo Drive West Suite 200, Largo MD 20774 (United States); Atkin, R. [Tiger Innovations, L.L.C., 3610 Vacation Lane, Arlington VA 22207 (United States); Marlin, L. [Naval Research Laboratory, Space Science Division, Washington DC 20375 (United States)

    2006-05-15

    High-resolution X-ray spectra were recorded by the High-Energy Electronic X-ray (HENEX) spectrometer from a variety of targets irradiated by the Omega laser at the Laboratory for Laser Energetics. The HENEX spectrometer utilizes four reflection crystals covering the 1-20keV energy range and one quartz(10-11) transmission crystal (Laue geometry) covering the 11-40keV range. The time-integrated spectral images were recorded on five CMOS X-ray detectors. In the spectra recorded from krypton-filled gasbag and hohlraum targets, the helium-like K-shell transitions n=1-2, 1-3, and 1-4 appeared in the 13-17keV energy range. A number of additional spectral features were observed at energies lower than the helium-like n=1-3 and n=1-4 transitions. Based on computational simulations of the spectra using the FLYCHK/FLYSPEC codes, which included opacity effects, these additional features are identified to be inner-shell transitions from the Li-like through N-like krypton charge states. The comparisons of the calculated and observed spectra indicate that these transitions are characteristic of the plasma conditions immediately after the laser pulse when the krypton density is 2x10{sup 18}cm{sup -3} and the electron temperature is in the range 2.8-3.2keV. These spectral features represent a new diagnostic for the charge state distribution, the density and electron temperature, and the plasma opacity. Laboratory experiments indicate that it is feasible to record K-shell spectra from gold and higher Z targets in the >60keV energy range using a Ge(220) transmission crystal.

  17. High spatial resolution and high contrast visualization of brain arteries and veins. Impact of blood pool contrast agent and water-selective excitation imaging at 3T

    International Nuclear Information System (INIS)

    Spuentrup, E.; Jacobs, J.E.; Kleimann, J.F.

    2010-01-01

    Purpose: To investigate a blood pool contrast agent and water-selective excitation imaging at 3 T for high spatial and high contrast imaging of brain vessels including the veins. Methods and Results: 48 clinical patients (47 ± 18 years old) were included. Based on clinical findings, twenty-four patients received a single dose of standard extracellular Gadoterate-meglumine (Dotarem registered ) and 24 received the blood pool contrast agent Gadofosveset (Vasovist registered ). After finishing routine MR protocols, all patients were investigated with two high spatial resolution (0.15 mm 3 voxel size) gradient echo sequences in random order in the equilibrium phase (steady-state) as approved by the review board: A standard RF-spoiled gradient-echo sequence (HR-SS, TR/TE 5.1 / 2.3 msec, FA 30 ) and a fat-suppressed gradient-echo sequence with water-selective excitation (HR-FS, 1331 binominal-pulse, TR/TE 8.8 / 3.8 msec, FA 30 ). The images were subjectively assessed (image quality with vessel contrast, artifacts, depiction of lesions) by two investigators and contrast-to-noise ratios (CNR) were compared using the Student's t-test. The image quality and CNR in the HR-FS were significantly superior compared to the HR-SS for both contrast agents (p < 0.05). The CNR was also improved when using the blood pool agent but only to a minor extent while the subjective image quality was similar for both contrast agents. Conclusion: The utilized sequence with water-selective excitation improved image quality and CNR properties in high spatial resolution imaging of brain arteries and veins. The used blood pool contrast agent improved the CNR only to a minor extent over the extracellular contrast agent. (orig.)

  18. Electron drift velocity measurements in liquid krypton-methane mixtures

    CERN Document Server

    Folegani, M; Magri, M; Piemontese, L

    1999-01-01

    Electron drift velocities have been measured in liquid krypton, pure and mixed with methane at different concentrations (1-10% in volume) versus electric field strength, and a possible effect of methane on electron lifetime has been investigated. While no effect on lifetime could be detected, since lifetimes were in all cases longer than what measurable, a very large increase in drift velocity (up to a factor 6) has been measured.

  19. Krypton ventilation imaging using dual-energy CT in chronic obstructive pulmonary disease patients: initial experience.

    Science.gov (United States)

    Hachulla, Anne-Lise; Pontana, François; Wemeau-Stervinou, Lidwine; Khung, Suonita; Faivre, Jean-Baptiste; Wallaert, Benoit; Cazaubon, Jean-François; Duhamel, Alain; Perez, Thierry; Devos, Patrick; Remy, Jacques; Remy-Jardin, Martine

    2012-04-01

    To evaluate the tolerance and level of enhancement achievable after inhalation of stable krypton. This study was approved by the institutional review board and the local ethics committee. Written informed consent was obtained from all subjects. The study was planned as a Fleming two-stage design, enabling one to assess the effectiveness of a newer treatment or technique on a small number of patients. At the end of each stage, the results are computed, and the trial can be stopped if the effectiveness is less than a minimum success rate or greater than an expected success rate. After informed consent was obtained, a total of 32 patients (ie, two successive series of 16 patients each) with severe emphysema underwent a dual-source, dual-energy chest computed tomographic (CT) examination after inhalation of a mixture of stable krypton (80%) and oxygen (20%), with reconstruction of diagnostic and ventilation images. For each patient, two regions of interest were selected on a diagnostic image, one in a region of severe emphysema (presumed to be poorly ventilated or not ventilated) and a second one in a region devoid of structural abnormalities (presumed to be normally ventilated), with measurements of attenuation values on the corresponding ventilation image. All examinations were successfully performed, without adverse effects. Differences in attenuation between normal lung and emphysematous areas were found in 28 patients (88%; 95% confidence interval: 71%, 96.5%). The maximal level of attenuation within normal lung was 18.5 HU. Krypton attenuation difference between normal and emphysematous lung was significant, with a median value of 51.8% (P krypton and its excellent clinical tolerance makes this gas eligible for ventilation CT examinations. © RSNA, 2012.

  20. Liquid Krypton Calorimeter Calibration Software

    CERN Document Server

    Hughes, Christina Lindsay

    2013-01-01

    Calibration of the liquid krypton calorimeter (LKr) of the NA62 experiment is managed by a set of standalone programs, or an online calibration driver. These programs are similar to those used by NA48, but have been updated to utilize classes and translated to C++ while maintaining a common functionality. A set of classes developed to handle communication with hardware was used to develop the three standalone programs as well as the main driver program for online calibration between bursts. The main calibration driver has been designed to respond to run control commands and receive burst data, both transmitted via DIM. In order to facilitate the process of reading in calibration parameters, a serializable class has been introduced, allowing the replacement of standard text files with XML configuration files.

  1. In situ measurements of krypton in xenon gas with a quadrupole mass spectrometer following a cold-trap at a temporarily reduced pumping speed

    International Nuclear Information System (INIS)

    Brown, E; Rosendahl, S; Huhmann, C; Weinheimer, C; Kettling, H

    2013-01-01

    A new method for measuring trace amounts of krypton in xenon using a cold trap with a residual gas analyzer has been developed, which achieves an increased sensitivity by temporarily reducing the pumping speed while expending a minimal amount of xenon. By partially closing a custom built butterfly valve between the measurement chamber and the turbomolecular pump, a sensitivity of 40 ppt has been reached. This method has been tested on an ultra-pure gas sample from Air Liquide with an unknown intrinsic krypton concentration, yielding a krypton concentration of 330±200 ppt.

  2. Gated blood pool studies with a single probe - clinical validity

    International Nuclear Information System (INIS)

    Loesel, E.; Hoffmann, G.

    1981-01-01

    The global volume alterations of the heart can be estimated non-invasively by means of the radiocardiographic function analysis developed by Hoffmann and Kleine. Since the failing heart with its functional disturbances demonstrates a pathological volume behaviour under physical exercise, it is possible to use these characteristics to differentiate between the intact heart and the failing heart by registration of the global volume alterations. The gated blood pool technique combined with the registration of the intraventricular pressure pulse by means of a Swan-Ganz flow-directed catheter enables demonstration of ventricular stroke work as a pressure-volume loop (work diagram). Its shape indicates whether the ventricle has to perform mainly pressure work or volume work. Myocardial failure is altering the basic conditions of the heart. The work diagram of the failing heart is significantly different from that of the intact human heart. It is shifted in its pressure-volume coordinates according to an increase of EDV and ESV and the rise of the filling pressure. Case demonstrations reveal the global volume behaviour of the heart under varying conditions: resting and physical exercise, drug influence on the intact and failing heart. (orig.) [de

  3. Global spiral structure of M81 - radio continuum maps

    International Nuclear Information System (INIS)

    Bash, F.N.; Kaufman, M.; Ohio State Univ., Columbus)

    1986-01-01

    VLA observations of the radio continuum emission from M81 at 6 and 20 cm are presented and used to check the predictions of density-wave theories. Both thermal and nonthermal radiation from the spiral arms are detected. Most of the bright knots along the radio arms are giant radio H II regions. The nonthermal emission defines spiral arms that are patchy and well-resolved, with a width of 1-2 kpc. The observed nonthermal arms are too broad to agree with the continuum gasdynamical calculations of Roberts (1969), Shu et al. (1972), and Visser (1978, 1980) for a classical density wave model. The observed arm widths appear consistent with the predictions of density-wave models that emphasize the clumpy nature of the ISM. The 20 cm arms appear to spiral outward from a faint inner H I ring, suggesting that the ring is produced by the inner Lindblad resonance. 36 references

  4. Assessment of pulmonary ventilation/perfusion ratio by dual radionuclides SPECT using 81mKr gas and 99mTc-MAA

    International Nuclear Information System (INIS)

    Sando, Yoshichika

    1994-01-01

    The accuracy and clinical availability of pulmonary ventilation/perfusion (V/Q) ratio images by 81m Kr gas and 99m Tc-MAA dual radionuclides SPECT was assessed in 10 normal volunteers and 31 patients with pulmonary diseases. After equalizing the total acquisition counts of both radionuclides, the ratio of 81m Kr/ 99m Tc count was calculated in each pixel and expressed as the functional map of V/Q. Then, the histogram of pixel numbers against V/Q ratio was drawn and the center of weight (CW) and standard deviation (SD) of the distribution were determined. The reproducibility of this method was excellent. In normal volunteers, CW was 1.07 and the SD was 0.25. The V/Q was lower in dorsal than in the ventral portion. SD was large and lobar or segmental high V/Q areas were clearly noted in the patients with pulmonary vascular diseases. In pulmonary emphysema, large low V/Q areas coexisted with patchy high V/Q areas. CW was small and SD was large in this group. There was a significant positive correlation between SD and P A-a O 2 . The author believes that the pulmonary ventilation/perfusion (V/Q) ratio images by dual radionuclides SPECT is a useful diagnostic procedure. Further, SD determined by this examination is thought to be a good parameter of uneven distribution of pulmonary ventilation and perfusion. (author)

  5. QUANTIFYING THE HEATING SOURCES FOR MID-INFRARED DUST EMISSIONS IN GALAXIES: THE CASE OF M 81

    Energy Technology Data Exchange (ETDEWEB)

    Lu, N.; Zhao, Y. [Infrared Processing and Analysis Center, California Institute of Technology, MS 100-22, Pasadena, CA 91125 (United States); Bendo, G. J. [Jordrell Bank Center for Astrophysics, School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Boselli, A. [Laboratoire d' Astrophysique de Marseille-LAM, Université d' Aix-Marseille and CNRS, UMR7326, 38 rue F. Joliot-Curie, F-13388 Marseille Cedex 13 (France); Baes, M.; De Looze, I. [Sterrenkundig Observatorium, Universiteit Gent, Krijgslaan 281 S9, B-9000 Gent (Belgium); Wu, H.; Lam, M. I. [Key Laboratory of Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, A20 Datun Road, Beijing 100012 (China); Madden, S. C.; Rémy-Ruyer, A. [Laboratoire AIM, CEA, Université Paris VII, IRFU/Service d' Ástrophysique, Bat. 709, F-91191 Gif-sur-Yvette (France); Boquien, M. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge, CB3 0HA (United Kingdom); Wilson, C. D. [Department of Physics and Astronomy, McMaster University, Hamilton, Ontario L8S 4M1 (Canada); Galametz, M. [European Southern Observatory, Karl-Schwarzschild-Str. 2, D-85748 Garching-bei-Mnchen (Germany); Cooray, A. [Department of Physics and Astronomy, University of California, Irvine, CA 92697 (United States); Spinoglio, L., E-mail: lu@ipac.caltech.edu [Istituto di Astrofisica e Planetologia Spaziali, INAF, Via Fosso del Cavaliere 100, I-00133 Roma (Italy)

    2014-12-20

    With the newly available photometric images at 250 and 500 μm from the Herschel Space Observatory, we study quantitative correlations over a sub-kiloparsec scale among three distinct emission components in the interstellar medium of the nearby spiral galaxy M 81 (NGC 3031): (1) I {sub 8} or I {sub 24}, the surface brightness of the mid-infrared emission observed in the Spitzer Space Telescope 8 or 24 μm band, with I {sub 8} and I {sub 24} being dominated by the emissions from polycyclic aromatic hydrocarbons (PAHs) and very small grains (VSGs) of dust, respectively; (2) I {sub 500}, that of the cold dust continuum emission in the Herschel Space Observatory 500 μm band, dominated by the emission from large dust grains heated by evolved stars; and (3) I {sub Hα}, a nominal surface brightness of the Hα line emission, from gas ionized by newly formed massive stars. The results from our correlation study, free from any assumption on or modeling of dust emissivity law or dust temperatures, present solid evidence for significant heating of PAHs and VSGs by evolved stars. In the case of M 81, about 67% (48%) of the 8 μm (24 μm ) emission derives its heating from evolved stars, with the remainder attributed to radiation heating associated with ionizing stars.

  6. Theory of attosecond absorption spectroscopy in krypton

    DEFF Research Database (Denmark)

    Baggesen, Jan Conrad; Lindroth, Eva; Madsen, Lars Bojer

    2012-01-01

    A theory for time-domain attosecond pump–attosecond probe photoabsorption spectroscopy is formulated and related to the atomic response. The theory is illustrated through a study of attosecond absorption spectroscopy in krypton. The atomic parameters entering the formulation such as energies...... of the hole in this manner. In a second example, a hole is created in an inner shell by the first pulse, and the second probe pulse couples an even more tightly bound state to that hole. The hole decays in this example by Auger electron emission, and the absorption spectroscopy follows the decay of the hole...

  7. Prospect of drug distribution to hepatic cancer in intra-arterial infusion chemotherapy. Examination by infusion of sup(81m)Kr and /sup 133/Xe via catheter into hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Y; Imaoka, S; Matsui, Y; Ishikawa, O; Taniguchi, K [Osaka Prefectural Center for Adult Diseases (Japan)

    1982-04-01

    Cannulation into the hepatic artery under laparotomy was performed to nine patients of non-resectable hepatic cancer (eight of hepatocellular carcinoma, and one of cholangiocellular carcinoma), and injected sup(81m)Kr (Tsub(1/2) = 13 sec.) continuously via catheter into hepatic artery as the model of continuous intra-arterial infusion chemotherapy, and /sup 133/Xe (Tsub(1/2) = 5.3 days) by bolus injection as the model of one-shot ones. During and immediately after injection, sequential scintigrams were carried out and simultaneously images were acquired on a medical computer. Higher radioactivities of both sup(81m)Kr and /sup 133/Xe were observed in tumor than non-tumor region in seven of eight patients of hepatocellular carcinoma. The radioactive ratio of tumor to non-tumor (T/C ratio) was over 1.0 in these cases. This result indicated that there was more arterial blood flow in tumor than non-tumor region, and it could be expected to obtain higher distribution of drugs in tumor on both continuous and one-shot infusion chemotherapy. The pattern of distribution of sup(81m)Kr changed according to positions of patients, and in some cases T/C ratio was higher in other positions than supine position. The most effective position of the intra-arterial infusion chemotherapy could be selected by this method. This technique seems to make it possible to prospect the arrival of drugs to the tumor and presume the effectiveness of intra-arterial infusion chemotherapy.

  8. Whole-body magnetic resonance angiography with blood-pool agents

    International Nuclear Information System (INIS)

    Kramer, H.; Morana, G.

    2007-01-01

    Although often asymptomatic, peripheral arterial disease (PAD) is associated with significant morbidity in a large proportion of patients. Atherosclerosis is the underlying pathology in many instances, involving the whole arterial tree. Whole-body magnetic resonance angiography (MRA) permits rapid, non-invasive and accurate evaluation of the entire vascular system and can be used for both diagnostic purposes and monitoring of vascular involvement in diseases such as diabetes, Marfan's syndrome and Takayasu arteritis. MRA has been used successfully in the identification of high-grade stenosis in PAD, abnormalities of the ileocaval veins and carotid plaque imaging. Carotid disease is significantly correlated with severe coronary artery disease and renal artery atherosclerosis. Symptomatic lesions in one vascular bed are often related to additional asymptomatic atherosclerotic lesions in other vascular regions. MRA may be advantageous over computed tomographic angiography because it can be performed with contrast media virtually devoid of serious toxicity and without utilization of ionizing radiation. Display of the entire arterial vasculature can be achieved in < 90 s, with excellent sensitivity and specificity. Recent technological advances, such as parallel imaging and the implementation of dedicated matrix coils, have further increased image quality, and in combination with the blood-pool contrast agents, such as gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany), extended imaging time, higher spatial resolution and larger anatomical coverage can be achieved. (orig.)

  9. Whole-body magnetic resonance angiography with blood-pool agents

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, H. [Inst. for Clinical Radiology, Univ. Hospital Munich, Munich (Germany); Morana, G. [Radiological Dept., Hospital Ca' Foncello, Treviso (Italy)

    2007-03-15

    Although often asymptomatic, peripheral arterial disease (PAD) is associated with significant morbidity in a large proportion of patients. Atherosclerosis is the underlying pathology in many instances, involving the whole arterial tree. Whole-body magnetic resonance angiography (MRA) permits rapid, non-invasive and accurate evaluation of the entire vascular system and can be used for both diagnostic purposes and monitoring of vascular involvement in diseases such as diabetes, Marfan's syndrome and Takayasu arteritis. MRA has been used successfully in the identification of high-grade stenosis in PAD, abnormalities of the ileocaval veins and carotid plaque imaging. Carotid disease is significantly correlated with severe coronary artery disease and renal artery atherosclerosis. Symptomatic lesions in one vascular bed are often related to additional asymptomatic atherosclerotic lesions in other vascular regions. MRA may be advantageous over computed tomographic angiography because it can be performed with contrast media virtually devoid of serious toxicity and without utilization of ionizing radiation. Display of the entire arterial vasculature can be achieved in < 90 s, with excellent sensitivity and specificity. Recent technological advances, such as parallel imaging and the implementation of dedicated matrix coils, have further increased image quality, and in combination with the blood-pool contrast agents, such as gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany), extended imaging time, higher spatial resolution and larger anatomical coverage can be achieved. (orig.)

  10. Irradiation temperature memorization by retention of krypton-85. Application to the temperature determination for the internal cladding surface of fuel elements in PWR

    International Nuclear Information System (INIS)

    Fremiot, Claude

    1977-01-01

    The temperature of the inner surface of the cladding fuel elements, which can not be measured directly, can be determined after irradiation. During its stage within the reactor, the cladding is bombarded by krypton-85 fission product, which is trapped in the metallic lattice defects. The experience shows that the krypton release during postirradiation heating takes place at the irradiation temperature. This method was applied for PWR fuel element. A very simple model for retention and release of the krypton is proposed. The krypton trap-energy in zircaloy partakes in this model. This technique can be ordered amongst the Hot'Lab' control methods and expert appraisements. It is pointed out that the principal interest in that method is the fact that it does not need any fuel element instrumentation. At the present, this method is being used by CEA for routine-control. [fr

  11. An experimental study of the trapping and release of krypton in nickel

    International Nuclear Information System (INIS)

    Donnelly, S.E.; Ingram, D.C.; Armour, D.G.

    1979-01-01

    An experimental study is reported of the trapping and release of krypton implanted into nickel at low energies ( + incident on Ni (110) the maximum quantity of gas retained in the target was found to be approximately 2.5 x 10 15 ions cm -2 . (author)

  12. Analysis of sodium pool fire in SFEF for assessing the limiting pool fire

    International Nuclear Information System (INIS)

    Mangarjuna Rao, P.; Ramesh, S.S.; Nashine, B.K.; Kasinathan, N.; Chellapandi, P.

    2011-01-01

    Accidental sodium leaks and resultant sodium fires in Liquid Metal Fast Breeder Reactor (LMFBR) systems can create a threat to the safe operation of the plant. To avoid this defence-in depth approach is implemented from the design stage of reactor itself. Rapid detection of sodium leak and fast dumping of the sodium into the storage tank of a defective circuit, leak collection trays, adequate lining of load bearing structural concrete and extinguishment of the sodium fire are the important defensive measures in the design, construction and operation of a LMFBR for protection against sodium leaks and their resultant fires. Evaluation of sodium leak events and their consequences by conducting large scale engineering experiments is very essential for effective implementation of the above protection measures for sodium fire safety. For this purpose a Sodium Fire Experimental Facility (SFEF) is constructed at SED, IGCAR. SFEF is having an experimental hall of size 9 m x 6 m x 10 m with 540 m 3 volume and its design pressure is 50 kPa. It is a concrete structure and provided with SS 304 liner, which is fixed to the inside surfaces of walls, ceiling and floor. A leak tight door of size (1.8 m x 2.0 m) is provided to the experimental hall and the facility is provided with a sodium equipment hall and a control room. Experimental evaluation of sodium pool fire consequences is an important activity in the LMFBR sodium fire safety related studies. An experimental program has been planned for different types of sodium fire studies in SFEF. A prior to that numerical analysis have been carried out for enclosed sodium pool fires using SOFIRE-II sodium pool fire code for SFEF experimental hall configuration to evaluate the limiting pool fire. This paper brings out results of the analysis carried out for this purpose. Limiting pool fire of SFEF depends on the exposed surface area of the pool, amount of sodium in the pool, oxygen concentration and initial sodium temperature. Limiting

  13. Theoretical investigation of the secondary ionization in krypton and xenon

    International Nuclear Information System (INIS)

    Saffo, M.E.

    1986-01-01

    A theoretical investigation of the secondary ionization processes that responsible for the pre-breakdown ionization current growth in a uniform electric field was studied in krypton and xenon gases, especially at low values of E/P 0 which is corresponding to high values of pressure, since there are a number of possible secondary ionization processes. It is interesting to carry out a quantitative analysis for the generalized secondary ionization coefficient obtained previously by many workers in terms of the production of excited states and their diffusion to the cathode and their destruction rate in the gas body. From energy balance equation for the electrons in the discharge, the fractional percentage energy losses of ionization, excitation, and elastic collisions to the total energy gained by the electron from the field has been calculated for krypton and xenon, as a result of such calculations; the conclusion drawn is that at low values of E/P 0 the main energy loss of electrons are in excited collision. Therefore, we are adopting a theoretical calculation for W/α under the assumption that the photo-electron emission at the cathode is the predominated secondary ionization process. 14 tabs.; 12 figs.; 64 refs

  14. Human parvovirus PARV4 in plasma pools of Chinese origin.

    Science.gov (United States)

    Ma, Y-Y; Guo, Y; Zhao, X; Wang, Z; Lv, M-M; Yan, Q-P; Zhang, J-G

    2012-10-01

    Human parvovirus 4 (PARV4) is present in blood and blood products. As the presence and levels of PARV4 in Chinese source plasma pools have never been determined, we implemented real-time quantitative PCR to investigate the presence of PARV4 in source plasma pools in China. Results showed that 26·15% (51/195) of lots tested positive for PARV4. The amounts of DNA ranged from 2·83 × 10(3) copies/ml to 2·35×10(7) copies/ml plasma. The high level of PARV4 in plasma pools may pose a potential risk to recipients. Further studies on the pathogenesis of PARV4 are urgently required. © 2012 The Author(s). Vox Sanguinis © 2012 International Society of Blood Transfusion.

  15. Clinical studies on combined ventilation (sup(81m)Kr)/perfusion (sup(99m)Tc-MAA) scintigraphy

    International Nuclear Information System (INIS)

    Yamamoto, Keiichiro; Miyamae, Tatsuya

    1983-01-01

    One hundred fifty patients having pulmonary disease underwent pulmonary scintigraphy sequentially with sup(99m)Tc-MAA and sup(81m)Kr gases. Scintigrams of matched defect were obtained from 113 (75.3%) of the 150 patients, considered to be nonspecific universal pattern of a pulmonary disease. Scintigrams of mismatched defect (absent perfusion and homogeneous ventilation) were obtained from 20 patients (13.3%), including 6 with lung carcinoma, 3 with pulmonary embolism, 3 with connective tissue disease, 2 with aortitis syndrome and 6 with other diseases. Scintigrams of mismatch with impaired ventilation and normal perfusion were mainly seen in chronic obstructive lung diseases. Of the 10 patients with bronchial asthma, 5 had scintigrams of improved ventilation after intravenous injection of 250 mg aminophilline, but none of patients with emphysema. The combined scintigraphy has made significant contributions to diagnosis and management of patients with pulmonary disease where the chest X-ray is unhelpful. (author)

  16. Efficacy of krypton laser photodynamic therapy for oral mucosa dysplasia in 9,10-dimethyl-1,2-benzanthracene-treated hamsters.

    Science.gov (United States)

    Shen, Lingyue; Xu, Qing; Li, Pingping; Zhou, Guoyu

    2013-11-01

    The present study aimed to evaluate the efficacy of krypton laser photodynamic therapy (PDT) with PsD-007 for the treatment of oral mucosa dysplasia in 9,10-dimethyl-1,2-benzanthracene (DMBA)-treated hamsters. A DMBA-induced hamster cheek pouch model of precancerous lesions was created and the resultant 25 hamsters were divided into five groups. The right side was treated with PDT and the left side was used as the positive control. Following systemic anesthesia, an incision was made in the groin area to expose the femoral vein. PsD-007 was administered intravenously through the femoral vein. Various doses of photosensitizer were used to treat groups A-E. Subsequent to closing the incision, the right side of the buccal mucosa was irradiated with light using the krypton laser at a wavelength of 413 nm, a power density of 150 mW/cm 2 and an irradiation time of 20 min. At six weeks post-surgery, the response was analyzed using histological examinations of the buccal pouch mucosa. A total of 24 hamsters completed the six-week observation period, as one hamster from group C died in the second week following the PDT. Of all 24 irradiated sides, 15 formed normal mucosal tissues and nine demonstrated mild dysplasia. Of the total control sides, six developed moderate dysplasia, five developed severe dysplasia and 13 progressed to carcinoma in situ or squamous cell carcinoma (SCC). The results revealed a significant difference between the two sides (P10 mg/kg, there was no statistical difference (P>0.05). PsD-007-mediated krypton laser PDT is effective for the treatment of oral mucosa dysplasia in hamsters.

  17. AA stacking, tribological and electronic properties of double-layer graphene with krypton spacer.

    Science.gov (United States)

    Popov, Andrey M; Lebedeva, Irina V; Knizhnik, Andrey A; Lozovik, Yurii E; Potapkin, Boris V; Poklonski, Nikolai A; Siahlo, Andrei I; Vyrko, Sergey A

    2013-10-21

    Structural, energetic, and tribological characteristics of double-layer graphene with commensurate and incommensurate krypton spacers of nearly monolayer coverage are studied within the van der Waals-corrected density functional theory. It is shown that when the spacer is in the commensurate phase, the graphene layers have the AA stacking. For this phase, the barriers to relative in-plane translational and rotational motion and the shear mode frequency of the graphene layers are calculated. For the incommensurate phase, both of the barriers are found to be negligibly small. A considerable change of tunneling conductance between the graphene layers separated by the commensurate krypton spacer at their relative subangstrom displacement is revealed by the use of the Bardeen method. The possibility of nanoelectromechanical systems based on the studied tribological and electronic properties of the considered heterostructures is discussed.

  18. Photochemistry of the ozone-water complex in cryogenic neon, argon, and krypton matrixes.

    Science.gov (United States)

    Tsuge, Masashi; Tsuji, Kazuhide; Kawai, Akio; Shibuya, Kazuhiko

    2013-12-12

    The photochemistry of ozone-water complexes and the wavelength dependence of the reactions were studied by matrix isolation FTIR spectrometry in neon, argon, and krypton matrixes. Hydrogen peroxide was formed upon the irradiation of UV light below 355 nm. Quantitative analyses of the reactant and product were performed to evaluate the matrix cage effect of the photoreaction. In argon and krypton matrixes, a bimolecular O((1)D) + H2O → H2O2 reaction was found to occur to form hydrogen peroxide, where the O((1)D) atom generated by the photolysis of ozone diffused in the cryogenic solids to encounter water. In a neon matrix, hydrogen peroxide was generated through intracage photoreaction of the ozone-water complex, indicating that a neon matrix medium is most appropriate to study the photochemistry of the ozone-water complex.

  19. Removing krypton from xenon by cryogenic distillation to the ppq level

    Energy Technology Data Exchange (ETDEWEB)

    Aprile, E.; Anthony, M.; De Perio, P.; Gao, F.; Goetzke, L.W.; Greene, Z.; Messina, M.; Plante, G.; Rizzo, A.; Zhang, Y. [Columbia University, Physics Department, New York, NY (United States); Aalbers, J.; Breur, P.A.; Brown, A.; Colijn, A.P.; Decowski, M.P.; Hogenbirk, E.; Tiseni, A. [Nikhef and the University of Amsterdam, Science Park, Amsterdam (Netherlands); Agostini, F. [INFN-Laboratori Nazionali del Gran Sasso (Italy); Gran Sasso Science Institute, L' Aquila (Italy); University of Bologna, Department of Physics and Astrophysics, Bologna (Italy); INFN-Bologna (Italy); Alfonsi, M.; Geis, C.; Grignon, C.; Oberlack, U.; Scheibelhut, M.; Schindler, S. [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Amaro, F.D.; Cardoso, J.M.R.; Lopes, J.A.M.; Orrigo, S.E.A.; Santos, J.M.F. dos; Silva, M. [University of Coimbra, Department of Physics, Coimbra (Portugal); Arneodo, F.; Benabderrahmane, M.L.; Di Giovanni, A.; Maris, I. [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Barrow, P.; Baudis, L.; Franco, D.; Galloway, M.; Kessler, G.; Kish, A.; Mayani, D.; Pakarha, P.; Piastra, F.; Wei, Y.; Wulf, J. [Physik-Institut, University of Zurich, Zurich (Switzerland); Bauermeister, B. [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Stockholm University, AlbaNova, Oskar Klein Centre, Department of Physics, Stockholm (Sweden); Berger, T.; Brown, E.; Piro, M.C. [Rensselaer Polytechnic Institute, Department of Physics, Applied Physics and Astronomy, Troy, NY (United States); Bruenner, S.; Cichon, D.; Eurin, G.; Hasterok, C.; Lindemann, S.; Lindner, M.; Undagoitia, T.M.; Pizzella, V.; Rauch, L.; Rupp, N.; Schreiner, J.; Simgen, H. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Bruno, G.; Gallo Rosso, A.; Molinario, A. [INFN-Laboratori Nazionali del Gran Sasso (Italy); Gran Sasso Science Institute, L' Aquila (Italy); Budnik, R.; Duchovni, E.; Itay, R.; Landsman, H.; Lellouch, D.; Levinson, L.; Manfredini, A.; Priel, N. [Weizmann Institute of Science, Department of Particle Physics and Astrophysics, Rehovot (Israel); Buetikofer, L.; Coderre, D.; Kaminsky, B.; Schumann, M.; Sivers, M. v. [Universitaet Freiburg, Physikalisches Institut, Freiburg (Germany); Calven, J.; Conrad, J.; Ferella, A.D.; Pelssers, B. [Stockholm University, AlbaNova, Oskar Klein Centre, Department of Physics, Stockholm (Sweden); Cervantes, M.; Lang, R.F.; Masson, D.; Pienaar, J.; Reichard, S.; Reuter, C. [Purdue University, Department of Physics and Astronomy, West Lafayette, IN (United States); Cussonneau, J.P.; Diglio, S.; Le Calloch, M.; Masbou, J.; Micheneau, K.; Persiani, R.; Thers, D. [Universite de Nantes, SUBATECH, Ecole des Mines de Nantes, CNRS/In2p3, Nantes (France); Di Gangi, P.; Garbini, M.; Massoli, F.V.; Sartorelli, G.; Selvi, M. [University of Bologna, Department of Physics and Astrophysics, Bologna (Italy); INFN-Bologna (Italy); Fei, J.; Ni, K.; Ye, J. [University of California, Department of Physics, San Diego, CA (United States); Fieguth, A.; Huhmann, C.; Murra, M.; Rosendahl, S.; Weinheimer, C. [Westfaelische Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Fulgione, W. [INFN-Laboratori Nazionali del Gran Sasso and Gran Sasso Science Institute, L' Aquila (Italy); INFN-Torino (Italy); Osservatorio Astrofisico di Torino, Torino (Italy); Grandi, L.; Saldanha, R.; Shockley, E.; Upole, N. [University of Chicago, Department of Physics and Kavli Institute of Cosmological Physics, Chicago, IL (United States); Lin, Q. [Laboratori Nazionali del Gran Sasso, Assergi (Italy); Meng, Y.; Stein, A.; Wang, H. [University of California, Physics and Astronomy Department, Los Angeles, CA (United States); Miguez, B.; Trinchero, G. [INFN-Torino (Italy); Osservatorio Astrofisico di Torino, Torino (Italy); Naganoma, J.; Shagin, P. [Rice University, Department of Physics and Astronomy, Houston, TX (United States); Lavina, L.S. [LPNHE, Universite Pierre et Marie Curie, Universite Paris Diderot, CNRS/IN2P3, Paris (France); Tunnell, C. [Nikhef and the University of Amsterdam, Science Park, Amsterdam (Netherlands); University of Chicago, Department of Physics and Kavli Institute of Cosmological Physics, Chicago, IL (United States); Cristescu, I. [Karlsruhe Institute of Technology, Tritium Laboratory Karlsruhe, Eggenstein-Leopoldshafen (Germany); Collaboration: XENON Collaboration

    2017-05-15

    The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β-emitter {sup 85}Kr which is present in the xenon. For XENON1T a concentration of natural krypton in xenon {sup nat}Kr/Xe < 200 ppq (parts per quadrillion, 1 ppq = 10{sup -15} mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4 . 10{sup 5} with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of {sup nat}Kr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN. (orig.)

  20. Rapid MR venography in children using a blood pool contrast agent and multi-station fat-water-separated volumetric imaging

    International Nuclear Information System (INIS)

    Ghanouni, Pejman; Walters, Shannon G.; Vasanawala, Shreyas S.

    2012-01-01

    A rapid, reliable radiation-free method of pediatric body venography might complement US by evaluating veins in the abdomen and pelvis and by providing a global depiction of venous anatomy. We describe a MR venography technique utilizing gadofosveset, a blood pool contrast agent, in children. The technique allows high-spatial-resolution imaging of the veins from the diaphragm to the knees in less than 15 min of total exam time. (orig.)

  1. [Krypton laser photocoagulation at low power setting for age-related macular degeneration complicated with subfoveal choroidal neovascularization].

    Science.gov (United States)

    Zhang, Cheng-fen; Jia, Yan; Li, Zhi-qing; Du, Hong; Han, Bao-ling

    2004-12-01

    To evaluate the efficacy of krypton laser photocoagulation for treatment of age-related macular degeneration (AMD) complicated with mainly subfoveal classic choroidal neovascularization (CNV). Seventeen eyes of 17 cases, aged 50 - 74 years (averaged 60.8 years) with mainly subfoveal classic choroidal neovascularization were treated with krypton laser at lower power setting. The treatment was completed in one session. Another course of treatment was given 4 weeks later if there was active leakage demonstrated at the CNV area. Visual acuity, anterior segment and fundus examination, perimetry test, fundus fluorescein angiography (FFA) and indocyanine green angiography (ICGA) were performed before and after treatment. The follow-up period was 3.5 years on average (1 - 8 years). There was no immediately decrease of visual acuity after treatment. All treated eyes showed absorption of hemorrhages and/or exudates and diminished leakages. Visual acuity was stable in 8 eyes; improved in 6 eyes (>/= 2 lines), and decreased in 3 eyes (Krypton laser photocoagulation at low power setting is an effective treatment for AMD with mainly classic subfoveal choroidal neovascularization.

  2. Technical requirements, biophysical considerations and protocol optimization with magnetic resonance angiography using blood-pool agents

    International Nuclear Information System (INIS)

    Rohrer, M.; Geerts-Ossevoort, L.; Laub, G.

    2007-01-01

    In order to maximize the potential benefits of contrast-enhanced magnetic resonance angiography, careful attention must be paid to the choice of hardware, data acquisition and processing, and to the choice of contrast agent. Typically, contrast-enhanced magnetic resonance angiography uses parallel-imaging techniques, which shorten the acquisition time, enhance spatial resolution and reduce artefacts. The timing of data acquisition is crucial for maximal enhancement of the arteries: for optimal arterial depiction, the centre of k-space should be acquired at the time of peak concentration of contrast agent in the arterial bed being investigated, and a number of k-space acquisition techniques are available to achieve this. SENSE or GRAPPA techniques can be used to facilitate parallel-imaging reconstruction of either the image data or k-space data, respectively. Gadolinium contrast agents shorten the proton relaxation times (most importantly T1) of blood, thereby increasing the signal-to-noise ratio and enhancing differentiation between blood vessels and other tissues. The blood-pool (intravascular) contrast agent gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is reversibly protein-bound in human plasma. This results in a marked increase in relaxivity, and hence a strong T1 shortening effect compared with other gadolinium-based contrast agents. Furthermore, the blood retention time of gadofosveset trisodium is substantially prolonged compared with conventional contrast agents. As a result, gadofosveset trisodium permits both first-pass and steady-state imaging. (orig.)

  3. Cooling process in separation devices of krypton gas

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, S; Sugimoto, K

    1975-06-11

    To prevent entry of impurities into purified gases and to detect leaks of heat exchanger in a separation and recovering device of krypton gas by means of liquefaction and distillation, an intermediate refrigerant having the same or slightly higher boiling point than that of gas to be cooled is used between the gas to be cooled (process gas) and refrigerant (nitrogen), and the pressure of the gas to be cooled is controlled to have a pressure higher than the intermediate refrigerant to cool the gas to be cooled.

  4. Justify of implementation of a hot water layer system in swimming pool research reactor IEA-R1m

    International Nuclear Information System (INIS)

    Toyoda, Eduardo Yoshio; Gordon, Ana Maria Pinho Leite; Sordi, Gian-Maria A.A.

    2001-01-01

    The IPEN/CNEN-SP has a swimming pool research reactor (IEA-R1m) in operation since 1957 at 2 MW. In 1998, after some modifications, its nominal power increased to 5 MW. Among these modifications some adaptations had to be accomplished in the radiological protection and operational procedure. The present work aim to study the need of implementation of a hot water layer in order to reduce the dose in the workers in the vicinity of the reactor swimming pool. Applying the principles of radioprotection optimization, it was concluded that the decision of the construction of one hot water layer system in the reactor swimming pool, is not necessary. (author)

  5. Breast tumor targeting with {sup 99m}Tc-HYNIC-PR81 complex as a new biologic radiopharmaceutical

    Energy Technology Data Exchange (ETDEWEB)

    Salouti, Mojtaba [Department of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Rajabi, Hossein [Department of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of)], E-mail: hrajabi@modares.ac.ir; Babaei, Mohammad Hossein [Department of Radioisotope, Atomic Energy Organization of Iran, Tehran (Iran, Islamic Republic of); Rasaee, Mohammad Javad [Department of Medical Biotechnology, School of Medical Sciences, Tarbiat Modares University, Tehran (Iran, Islamic Republic of)

    2008-10-15

    Human epithelial mucin, MUC1, is commonly overexpressed in adenocarcinoma that includes more than 80% of breast cancers. The PR81 is a murine anti-MUC1 monoclonal antibody (MAb) that was prepared against the human breast cancer. We developed an indirect method for labeling of this antibody with {sup 99m}Tc in order to use the new preparation in immunoscintigraphy studies of BALB/c mice bearing breast tumors. The {sup 99m}Tc-PR81 complex was prepared using the HYNIC as a chelator and tricine as a coligand. The labeling efficiency determined by instant thin-layer chromatography (ITLC) was 89.2%{+-}4.7%, and radiocolloides measured by cellulose nitrate electrophoresis were 3.4%{+-}0.9%. The in vitro stability of labeled product was determined at room temperature by ITLC and in human serum by gel filtration chromatography - 88.3%{+-}4.6% and 79.8%{+-}5.7% over 24 h, respectively. The integrity of labeled MAb was checked by means of sodium dodecyl sulfate polyacrylamide gel electrophoresis, and no significant fragmentation was seen. The results of cell binding studies showed that both labeled and unlabeled PR81 were able to compete for binding to MCF 7 cells. Biodistribution studies performed in female BALB/c mice with breast tumor xenografts at 4, 16 and 24 h after the {sup 99m}Tc-HYNIC-PR81 injection demonstrated a specific localization of the compound at the site of tumors and minimum accumulation in non target organs. The tumor imaging was performed in BALB/c mice with breast xenograft tumors at 4, 8, 12, 16, 20, 24, 28, 32 and 36 h after the complex injection. The tumors were visualized with high sensitivity after 8 h. The findings showed that the new radiopharmaceutical is a promising candidate for radioimmunoscintigraphy of the human breast cancer.

  6. Development of a krypton-doped gas symmetry capsule platform for x-ray spectroscopy of implosion cores on the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Ma, T., E-mail: ma8@llnl.gov; Chen, H.; Patel, P. K.; Schneider, M. B.; Barrios, M. A.; Casey, D. T.; Hammel, B. A.; Berzak Hopkins, L. F.; Jarrott, L. C.; Khan, S. F.; Nora, R.; Pak, A.; Scott, H. A.; Spears, B. K.; Weber, C. R. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Chung, H.-K. [International Atomic Energy Agency, Vienna (Austria); Lahmann, B.; Sio, H. [Plasma Fusion and Science Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Rosenberg, M. J.; Regan, S. P. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States)

    2016-11-15

    The electron temperature at stagnation of an ICF implosion can be measured from the emission spectrum of high-energy x-rays that pass through the cold material surrounding the hot stagnating core. Here we describe a platform developed on the National Ignition Facility where trace levels of a mid-Z dopant (krypton) are added to the fuel gas of a symcap (symmetry surrogate) implosion to allow for the use of x-ray spectroscopy of the krypton line emission.

  7. Development of a krypton-doped gas symmetry capsule platform for x-ray spectroscopy of implosion cores on the NIF.

    Science.gov (United States)

    Ma, T; Chen, H; Patel, P K; Schneider, M B; Barrios, M A; Casey, D T; Chung, H-K; Hammel, B A; Berzak Hopkins, L F; Jarrott, L C; Khan, S F; Lahmann, B; Nora, R; Rosenberg, M J; Pak, A; Regan, S P; Scott, H A; Sio, H; Spears, B K; Weber, C R

    2016-11-01

    The electron temperature at stagnation of an ICF implosion can be measured from the emission spectrum of high-energy x-rays that pass through the cold material surrounding the hot stagnating core. Here we describe a platform developed on the National Ignition Facility where trace levels of a mid-Z dopant (krypton) are added to the fuel gas of a symcap (symmetry surrogate) implosion to allow for the use of x-ray spectroscopy of the krypton line emission.

  8. Calculation of partial enthalpies in argon-krypton mixtures by NPT molecular dynamics

    NARCIS (Netherlands)

    Sindzingre, P.; Massobrio, C.; Ciccotti, G.; Frenkel, D.

    1989-01-01

    In an earlier paper, we have indicated how, by using a particle-insertion technique, partial molar enthalpies and related quantities can be evaluated from simulations on a single state point. In the present paper we apply this method to a Lennard-Jones argon-krypton mixture. For this particular

  9. Performance of an electromagnetic liquid krypton calorimeter based on a ribbon electrode tower structure

    Science.gov (United States)

    Barr, G. D.; Bruschini, C.; Bocquet, C.; Buchholz, P.; Cundy, D.; Doble, N.; Funk, W.; Gatignon, L.; Gonidec, A.; Hallgren, B.; Kesseler, G.; Lacourt, A.; Laverrière, G.; Linser, G.; Martini, M.; Norton, A.; Schinzel, D.; Seidl, W.; Sozzi, M. S.; Taureg, H.; Vossnack, O.; Wahl, H.; Wertelaers, P.; Weterings, J.; Ziolkowski, M.; Kalinin, A.; Kekelidze, V.; Kozhevnikov, Yu.; Bertolotto, L.; Carassiti, V.; Duclos, J.; Gianoli, A.; Frabetti, P. L.; Savriè, M.; Zeitnitz, O.; Calvetti, M.; Lubrano, P.; Pepe, M.; Calafiura, P.; Cerri, C.; Costantini, F.; Fantechi, R.; Gorini, B.; Mannelli, I.; Marzulli, V.; Bédérède, D.; Debu, P.; Givernaud, A.; Gosset, L.; Heitzmann, J.; Mazzucato, E.; Peyaud, B.; Turlay, R.; Biino, C.; Ceccucci, A.; Maas, P.; Palestini, S.; Cagliari-Cambridge-CERN-Dubna-Edinburgh-Ferrara-Mainz-Orsay-Perugia-Pisa-Saclay-Siegen-Torino-Vienna Collaboration

    1996-02-01

    The NA48 collaboration is preparing a new experiment at CERN aiming to study CP violation in the K 0- overlineK 0 system with an accuracy of 2 × 10 -4 in the parameter Re(ɛ'/ɛ). Decays in two π0's will be recorded by a quasi-homogeneous liquid krypton calorimeter. A liquid krypton calorimeter has been chosen to combine good energy, position and time resolution with precise charge calibration and long-term stability. The prototype calorimeter incorporating the final design of the electrode read-out structure is presented in this paper. An energy resolution of {≃3.5%}/{√E} with a constant term smaller than 0.5% has been obtained. The time resolution was found to be better than 300 ps above 15 GeV.

  10. Probing the accretion flow and emission-line regions of M81, the nearest broad-lined low-luminosity AGN

    Science.gov (United States)

    Barth, Aaron

    2017-08-01

    The nucleus of M81 is an object of singular importance as a template for low-luminosity accretion flows onto supermassive black holes. We propose to obtain a complete, small-aperture, high S/N STIS UV/optical spectrum of the M81 nucleus and multi-filter WFC3 imaging covering the UV through near-IR. Such data have never previously been obtained with HST; the only prior archival UV/optical spectra of M81 have low S/N, incomplete wavelength coverage, and are strongly contaminated by starlight. Combined with new Chandra X-ray data, our proposed observations will comprise the definitive reference dataset on the spectral energy distribution of this benchmark low-luminosity AGN. These data will provide unique new constraints on the possible contribution of a truncated thin accretion disk to the AGN emission spectrum, clarifying a fundamental property of low-luminosity accretion flows. The data will additionally provide new insights into broad-line region structure and black hole mass scaling relationships at the lowest AGN luminosities, and spatially resolved diagnostics of narrow-line region excitation conditions at unprecedented spatial resolution to assess the impact of the AGN on the ionization state of the gas in the host galaxy bulge.

  11. Charge state distribution studies of pure and oxygen mixed krypton ECR plasma - signature of isotope anomaly and gas mixing effect.

    Science.gov (United States)

    Kumar, Pravin; Mal, Kedar; Rodrigues, G

    2016-11-01

    We report the charge state distributions of the pure, 25% and 50% oxygen mixed krypton plasma to shed more light on the understanding of the gas mixing and the isotope anomaly [A. G. Drentje, Rev. Sci. Instrum. 63 (1992) 2875 and Y Kawai, D Meyer, A Nadzeyka, U Wolters and K Wiesemann, Plasma Sources Sci. Technol. 10 (2001) 451] in the electron cyclotron resonance (ECR) plasmas. The krypton plasma was produced using a 10 GHz all-permanent-magnet ECR ion source. The intensities of the highly abundant four isotopes, viz. 82 Kr (~11.58%), 83 Kr (~11.49%), 84 Kr (~57%) and 86 Kr (17.3%) up to ~ +14 charge state have been measured by extracting the ions from the plasma and analysing them in the mass and the energy using a large acceptance analyzer-cum-switching dipole magnet. The influence of the oxygen gas mixing on the isotopic krypton ion intensities is clearly evidenced beyond +9 charge state. With and without oxygen mixing, the charge state distribution of the krypton ECR plasma shows the isotope anomaly with unusual trends. The anomaly in the intensities of the isotopes having quite closer natural abundance, viz. 82 Kr, 86 Kr and 83 Kr, 86 Kr is prominent, whereas the intensity ratio of 86 Kr to 84 Kr shows a weak signature of it. The isotope anomaly tends to disappear with increasing oxygen mixing in the plasma. The observed trends in the intensities of the krypton isotopes do not follow the prediction of linear Landau wave damping in the plasma. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Automated Sampling and Extraction of Krypton from Small Air Samples for Kr-85 Measurement Using Atom Trap Trace Analysis

    International Nuclear Information System (INIS)

    Hebel, S.; Hands, J.; Goering, F.; Kirchner, G.; Purtschert, R.

    2015-01-01

    Atom-Trap-Trace-Analysis (ATTA) provides the capability of measuring the Krypton-85 concentration in microlitre amounts of krypton extracted from air samples of about 1 litre. This sample size is sufficiently small to allow for a range of applications, including on-site spot sampling and continuous sampling over periods of several hours. All samples can be easily handled and transported to an off-site laboratory for ATTA measurement, or stored and analyzed on demand. Bayesian sampling methodologies can be applied by blending samples for bulk measurement and performing in-depth analysis as required. Prerequisite for measurement is the extraction of a pure krypton fraction from the sample. This paper introduces an extraction unit able to isolate the krypton in small ambient air samples with high speed, high efficiency and in a fully automated manner using a combination of cryogenic distillation and gas chromatography. Air samples are collected using an automated smart sampler developed in-house to achieve a constant sampling rate over adjustable time periods ranging from 5 minutes to 3 hours per sample. The smart sampler can be deployed in the field and operate on battery for one week to take up to 60 air samples. This high flexibility of sampling and the fast, robust sample preparation are a valuable tool for research and the application of Kr-85 measurements to novel Safeguards procedures. (author)

  13. Supershort avalanche electron beam in SF6 and krypton

    Science.gov (United States)

    Zhang, Cheng; Tarasenko, Victor F.; Gu, Jianwei; Baksht, Evgeni Kh.; Beloplotov, Dmitry V.; Burachenko, Alexander G.; Yan, Ping; Lomaev, Mikhail I.; Shao, Tao

    2016-03-01

    Runaway electrons play an important role in the avalanche formation in nanosecond- and subnanosecond- pulse discharges. In this paper, characteristics of a supershort avalanche electron beam (SAEB) generated at the subnanosecond and nanosecond breakdown in sulfur hexafluoride (SF6 ) in an inhomogeneous electric field were studied. One pulser operated at negative polarity with voltage pulse amplitude of ˜130 kV and rise time of 0.3 ns. The other pulser operated at negative polarity with voltage pulse amplitude of 70 kV and rise time of ˜1.6 ns . SAEB parameters in SF6 are compared with those obtained in krypton (Kr), nitrogen (N2 ), air, and mixtures of SF6 with krypton or nitrogen. Experimental results showed that SAEB currents appeared during the rise-time of the voltage pulse for both pulsers. Moreover, amplitudes of the SAEB current in SF6 and Kr approximately ranged from several to tens of milliamps at atmospheric pressure, which were smaller than those in N2 and air (ranging from hundreds of milliamps to several amperes). Furthermore, the concentration of SF6 additive could significantly reduce the SAEB current in N2-SF6 mixture, but it slightly affected the SAEB current in Kr -SF6 mixture because of the atomic/molecular ionization cross section of the gas had a much greater impact on the SAEB current rather than the electronegativity.

  14. CERN: From Russia with krypton

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    Full text: Arecent arrival at CERN is a cryostat built under the auspices of thelnternational Science and Technology Center (ISTC), a programme funded by the European Union, Japan, Russia, and the US which aims to promote the integration of former Soviet Union scientists and industry into global research and development activities. The new cryostat, built by Moscowbased Krunichev Enterprises, better known for its involvement in the ''Proton'' space rocket and the ''Mir'' space station, will form a vital part of the NA48 experiment at the SPS synchrotron. NA48, a Cagliari/Cambridge/CERN/ Dubna/Edinburgh/Ferrara/Mainz/Orsay/Perugia/Pisa/Saclay/Siegen/ Turin/Vienna collaboration, aims to study the small asymmetry in the properties of matter and antimatter known as CP violation, and should be fully ready to collect data next year. Through its links with Dubna's Joint Institute of Nuclear Research (JINR), near Moscow, NA48 has launched a number of initiatives designed to involve Russian physicists and industry in the experiment. The bargain 22 tonnes of krypton for NA48's energy-measuring calorimeter were manufactured at a specially- built factory in Russia. INTAS, the European Union-backed scheme for the promotion of cooperation with former Soviet Union scientists, provides funds for Dubna physicists to visit Western Europe. INTAS will also provide computing and networking infrastructure allowing the Russian physicists to participate fully in NA48's programme. As well as the cryostat, NA48's collaborating institutes have placed other orders with Russian suppliers. INFN Pisa has ordered 14,000 electrical feed-though contacts from the Budker Institute in Novosibirsk, whilst Saclay has placed contracts elsewhere for vacuum and other equipment. The new cryostat forms part of a joint project of INFN Pisa and CERN, involving scientists from Dubna, Edinburgh, and Saclay. The Russian part was built by Krunichev

  15. Maternal Malaria and Malnutrition (M3) initiative, a pooled birth cohort of 13 pregnancy studies in Africa and the Western Pacific

    DEFF Research Database (Denmark)

    Unger, Holger W; Cates, Jordan E; Gutman, Julie

    2016-01-01

    PURPOSE: The Maternal Malaria and Malnutrition (M3) initiative has pooled together 13 studies with the hope of improving understanding of malaria-nutrition interactions during pregnancy and to foster collaboration between nutritionists and malariologists. PARTICIPANTS: Data were pooled on 14 635...

  16. A megajoule class krypton fluoride amplifier for single shot, high gain ICF application

    International Nuclear Information System (INIS)

    Rose, E.; Hanson, D.; Krohn, B.; McLeod, J.; Kang, M.

    1988-01-01

    A design study is underway to define the optimal architecture for a KrF laser system which will deliver 10 MJ of 248-nm light to an ICF target. We present one approach which incorporates final power amplifiers in the megajoule class, achieving 10 MJ with four final amplifiers. Each double-pass laser amplifier employs two-sided electron-beam pumping of the laser gas medium. Details of the design are based on a Monte-Carlo electron-beam deposition code, a one-dimensional, time-dependent kinetics code, and pulsed power circuit modeling. Linear dimensions of the amplifier's extracted gain volume are 6.25 m in height and length and 5.12 m in width. Each amplifier handles 160 angularly multiplexed laser channels. The one-amagat, krypton-rich laser medium is e-beam pumped at 60-kW cm/sup /minus/3/ (4-MA at3.3-MV) over the 2-microsecond duration of the laser beam pulse train. 5 refs., 4 figs

  17. Monitoring of right ventricular function by single probe system (nuclear stethoscope) and sup(81m)Kr

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Ohmine, Hiromi; Kimura, Motomasa

    1982-01-01

    A single probe system (nuclear stethoscope) was developed to evaluate the monitoring of right ventricular function by sup(81m)Kr continuous infusion method. Optimal right ventricular and background positions were determined by position/monitor mode on beat-to-beat basis, and right ventricular ejection fraction (RVEF) was calculated by multi-gated method (MUGA). The correlation coefficient of nuclear stethoscope RVEF and camera-computer RVEF (MUGA) was 0.82, while the correlation coefficient of nuclear stethoscope RVEF and camera-computer RVEF (first-pass method) was 0.64. Therefore, the RVEF by nuclear stethoscope is useful for monitoring of right ventricular function. Clinical applications by sup(81m)Kr and nuclear stethoscope were as follows. 1. Exercise/rest RVEF is an extremely sensitive indicator to discriminate coronary artery disease (RCA occlusion) from normal subjects. 2. Beat-to-beat right ventricular volume response is useful for the monitoring of arrythmia such as atrial fibrillation. (author)

  18. Monitoring of right ventricular function by single probe system (nuclear stethoscope) and sup(81m)Kr

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Ohmine, Hiromi; Kimura, Motomasa [National Cardiovascular Center, Suita, Osaka (Japan)

    1982-12-01

    A single probe system (nuclear stethoscope) was developed to evaluate the monitoring of right ventricular function by sup(81m)Kr continuous infusion method. Optimal right ventricular and background positions were determined by position/monitor mode on beat-to-beat basis, and right ventricular ejection fraction (RVEF) was calculated by multi-gated method (MUGA). The correlation coefficient of nuclear stethoscope RVEF and camera-computer RVEF (MUGA) was 0.82, while the correlation coefficient of nuclear stethoscope RVEF and camera-computer RVEF (first-pass method) was 0.64. Therefore, the RVEF by nuclear stethoscope is useful for monitoring of right ventricular function. Clinical applications by sup(81m)Kr and nuclear stethoscope were as follows. 1. Exercise/rest RVEF is an extremely sensitive indicator to discriminate coronary artery disease (RCA occlusion) from normal subjects. 2. Beat-to-beat right ventricular volume response is useful for the monitoring of arrythmia such as atrial fibrillation.

  19. Soluble vascular endothelial growth factor in various blood transfusion components

    DEFF Research Database (Denmark)

    Nielsen, Hans Jørgen; Werther, K; Mynster, T

    1999-01-01

    of sVEGF was determined in nonfiltered and prestorage white cell-reduced whole blood (WB), buffy coat-depleted saline-adenine-glucose-mannitol (SAGM) blood, platelet-rich plasma (PRP), and buffy coat-derived platelet (BCP) pools obtained from volunteer, healthy blood donors. As a control, total content......-123) ng per mL in lysed cells. In SAGM blood, the median total sVEGF content was 25.3 (3.3-48.4) ng per unit in nonfiltered units and undetectable in white cell-reduced units. Median total sVEGF content was 29.2 (24.8-124.9) ng per unit in nonfiltered PRP and 28.7 (24.5-118.6) ng per unit in white cell......-reduced PRP. The sVEGF accumulated significantly in WB, SAGM blood, and BCP pools, depending on the storage time. CONCLUSION: The sVEGF (isotype 165) appears to be present in various blood transfusion components, depending on storage time....

  20. Operation and maintenance techniques of pool and pool water purification system in IMEF

    Energy Technology Data Exchange (ETDEWEB)

    Soong, Woong Sup

    1999-03-01

    IMEF pool is used pass way between pool and hot cell in order to inlet and outlet of fuel pin in cask. All operation is performed conforming with naked eyes. Therefore floating matter is filtered so as to easy under water handling. Also radioactivity in pool water is controlled according to the nuclear law, radioactivity ration maintained less than 15mR/hr on pool side. Perfect operation and maintenance can be achieved well trained operator. Result obtained from the perfection can give more influence over restrain, spreading contamination of radioactivity materials. This report describes operation and maintenance technique of pool water purification system in IMEF. (Author). 7 refs., 13 figs.

  1. Operation and maintenance techniques of pool and pool water purification system in IMEF

    International Nuclear Information System (INIS)

    Soong, Woong Sup

    1999-03-01

    IMEF pool is used pass way between pool and hot cell in order to inlet and outlet of fuel pin in cask. All operation is performed conforming with naked eyes. Therefore floating matter is filtered so as to easy under water handling. Also radioactivity in pool water is controlled according to the nuclear law, radioactivity ration maintained less than 15mR/hr on pool side. Perfect operation and maintenance can be achieved well trained operator. Result obtained from the perfection can give more influence over restrain, spreading contamination of radioactivity materials. This report describes operation and maintenance technique of pool water purification system in IMEF. (Author). 7 refs., 13 figs

  2. Red blood cells free α-haemoglobin pool: a biomarker to monitor the β-thalassemia intermedia variability. The ALPHAPOOL study.

    Science.gov (United States)

    Vasseur, Corinne; Domingues-Hamdi, Elisa; Ledudal, Katia; Le Corvoisier, Philippe; Barau, Caroline; Ghaleh, Bijan; Rialland, Amandine; Pissard, Serge; Galactéros, Frédéric; Baudin-Creuza, Véronique

    2017-10-01

    The severity of β-thalassaemia (β-thal) intermedia is mainly correlated to the degree of imbalanced α/non α-globin chain synthesis. The phenotypic diversity of β-thal depends on this imbalance and reflects all possible combinations of α- and β-globin genotypes, levels of fetal haemoglobin (HbF) and co-inheritance of other modulating factors. This study aimed to demonstrate the validity of a new surrogate of α/non α-globin biosynthetic ratio by measuring the soluble α-Hb pool in lysed red blood cells. Our results confirm that the α-Hb pool measurement allows a good discrimination between β-thal intermedia patients, controls and α-thal patients (P intermedia patients and may be clinically useful for monitoring the evolution of the disequilibrium of globin synthesis in response to treatments. © 2017 John Wiley & Sons Ltd.

  3. Production and recombination of radiation defects in argon and krypton crystals

    International Nuclear Information System (INIS)

    Giersberg, E.J.

    1981-01-01

    Relative changes in the lattice constants of argon and krypton crystals have been measured by X-ray diffraction. As a result X-ray irradiation is found to produce stable defects. The recombination behaviour of these defects can be determined by isochronous and isothermal annealing. The creation of primary defects can be explained by exciton excitation and double-ionisation. (orig.) [de

  4. The K Auger spectrum of krypton from the 83Rb decay

    International Nuclear Information System (INIS)

    Kovalik, A.; Gorozhankin, V.M.; Novgorodov, A.F.

    1990-01-01

    The K Auger spectrum of krypton was analyzed at the instrumental resolution of 6.5 eV using the evaporated 83 Rb source. The energies and relative intensities of the KLL-, KLX-, and KMX- Auger transitions were determined as well as the natural energy widths some of them. The results were compared with the theoretical predictions. 31 refs.; 3 figs.; 6 tabs

  5. Assessment of cardiac blood pool imaging in patients with left ventricular outflow tract stenosis

    International Nuclear Information System (INIS)

    Nakamura, Yutaka; Ono, Yasuo; Kohata, Tohru; Tsubata, Shinichi; Kamiya, Tetsuroh.

    1993-01-01

    We performed cardiac blood pool imagings with Tc-99m at rest and during supine ergometer exercise to evaluate left ventricular performance in 14 patients with left ventricular outflow tract stenosis. All catheterized patients were divided into two subgroups: 8 patients with peak systolic left ventricular to descending aortic pressure gradients of less than 50 mmHg (LPG group) and 6 patients with peak systolic gradients of more than 50 mmHg (HPG group). Control group included 10 patients without stenotic coronary lesions after Kawasaki disease. Left ventricular ejection fraction (LVEF) was obtained as systolic index; both filling fraction during the first third of diastole (1/3FF) and mean filling rate during the first third of diastole (1/3FR mean) were obtained as diastolic indices. None of the patients had abnormal findings on 201 Tl imaging. LVEF at rest in HPG group was significantly higher than those in control group, but LVEF in HPG group did not increase after exercise. It increased significantly in control group and LPG group. 1/3 FF in HPG group was significantly lower not only at rest but also during exercise. 1/3 FR mean at rest was not different significantly among the 3 groups. However, 1/3FR mean during exercise in LPG group was significantly lower; and 1/3 FR mean during exercise was significantly lower in HPG group than LPG group. The ratio of left ventricular muscular mass to left ventricular end-diastolic volume (M/V) calculated from left ventricular cineangiograms was different significantly among the 3 groups. The M/V ratio showed a correlation with LVEF and 1/3 FF both at rest and during exercise. These results would indicate that systolic function was impaired on exercise in severe left ventricular outflow tract stenosis and diastolic function was impaired on exercise in mild and severe left ventricular outflow tract stenosis. This may correlate with left ventricular hypertrophy and interaction of systolic function. (author)

  6. DLTS spectra of silicon diodes with p+-n-junction irradiated with high energy krypton ions

    Directory of Open Access Journals (Sweden)

    Nikolai A. Poklonski

    2016-06-01

    Full Text Available p+-n-Diodes have been studied. The diodes were manufactured on wafers (thickness 460 μm, (111 plane of uniformly phosphorus doped float-zone-grown single-crystal silicon. The resistivity of silicon was 90 Ω cm and the phosphorus concentration was 5×1013 cm−3. The diodes were irradiated with 250 MeV krypton ions. The irradiation fluence was 108 cm−2. Deep-level transient spectroscopy (DLTS was used to examine the defects induced by high energy krypton ion implantation. The DLTS spectra were recorded at a frequency of 1 MHz in the 78–290 K temperature range. The capacity-voltage characteristics have been measured at a reverse bias voltage from 0 to −19 V at a frequency of 1 MHz. We show that the main irradiation-induced defects are A-centers and divacancies. The behavior of DLTS spectra in the 150–260 K temperature range depends essentially on the emission voltage Ue. The variation of Ue allows us to separate the contributions of different defects into the DLTS spectrum in the 150–260 K temperature range. We show that, in addition to A-centers and divacancies, irradiation produces multivacancy complexes with the energy level Et = Ec−(0.5±0.02 eV and an electron capture cross section of ~4×10–13 cm2.

  7. Blood cell labeling with technetium-99m, (3)

    International Nuclear Information System (INIS)

    Uchida, Tatsumi; Akizuki, Tsuyoshi; Tanaka, Tetsugoro; Yui, Tokuo; Miura, Nobuo

    1978-01-01

    Spleen scintigraphy was performed by the use of sup(99m)Tc-labeled red blood cells which were prepared with a kit (TCK-11 produced by CIS) and were damaged by heating for 15 min at 49.0 +- 0.5 0 C or damaged chemically by treating with bromomerculi hydroxy propane (BMHP) 1.5 mg/2 ml of blood. The images obtained by scanner and scintillation camera were both favorable, and the author decided that this method is applicable to clinical spleen scintigraphy. The spleen scintigraphy with sup(99m)Tc-labeled red blood cells has many merits such as it gives a less exposure dose to patients under the examination so that it makes capable of repeated examinations, it uses a less volume of blood for labeling, and the procedure is not so complicated compared with the usual methods of 51 Cr-heating or 203 Hg- (or 197 Hg-) MHP. Therefore, this method is preferable to the other usual methods. (Ueda, J.)

  8. Melting line of Krypton in extreme thermodynamic regimes

    Directory of Open Access Journals (Sweden)

    Giuffre', E

    2007-01-01

    Full Text Available We have performed extensive computer simulations of the thermodynamic and structural properties of the krypton rare gas modeled by the modified Buckingham exponential-6 interatomic potential. Using a new set of potential parameters, we have found a good agreement with the room temperature equation of state at very high pressure obtained by diamond anvil cell experiments. Moreover, the melting line of the model has been estimated through the Lindemann criterion; the agreement with the low-pressure experiments is excellent, whereas at higher pressure, the model poorly reproduces the typical softening of the experimental melting curve.

  9. Four-body interaction energy for compressed solid krypton from quantum theory.

    Science.gov (United States)

    Tian, Chunling; Wu, Na; Liu, Fusheng; Saxena, Surendra K; Zheng, Xingrong

    2012-07-28

    The importance of the four-body contribution in compressed solid krypton was first evaluated using the many-body expansion method and the coupled cluster theory with full single and double excitations plus perturbative treatment of triples. All different four-atom clusters existing in the first- and second-nearest neighbor shells of face-centered cubic krypton were considered, and both self-consistent-field Hartree-Fock and correlation parts of the four-body interaction were accurately determined from the ambient conditions up to eightfold volume compression. We find that the four-body interaction energy is negative at compression ratio lower than 2, where the dispersive forces play a dominant role. With increasing the compression, the four-body contribution becomes repulsive and significantly cancels the over-softening effects of the three-body potential. The obtained equation of state (EOS) was compared with the experiments and the density-functional theory calculations. It shows that combination of the four-body effects with two- and three-body interactions leads to an excellent agreement with EOS measurements throughout the whole experimental range 0-130 GPa, and extends the prediction to 300 GPa.

  10. Acetylsalicylic acid and labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Adenilson de Souza da [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Dept. de Farmacologia e Psicobiologia; Frydman, Jacques Natan Grinapel; Rocha, Vanessa Camara da; Bernardo-Filho, Mario [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Dept. de Biofisica e Biometria

    2005-10-15

    Acetylsalicylic acid is the drug most used an anti-inflammatory agent and for secondary prevention of thrombotic phenomenon. Drugs can modify the labeling of blood constituents with technetium-99m (99m Tc). The aim of this work was to evaluate the effect of in vitro or in vivo assays with acetylsalicylic acid on the labeling of the blood constituents with 99m Tc. In vitro assay was performed with samples of whole blood from Wistar rats incubated with acetylsalicylic acid (1.0 mg/ml) for one hour before the 99m Tc-labeling process. For in vivo assay, Wistar rats were treated with acetylsalicylic acid (1.5 mg/kg) during one hour, and the whole blood was withdrawn for the 99m Tc-labeling process. Saline was used in control groups. Data showed that the fixation of 99m Tc to the blood constituents was not significantly (p>0.05) modified in in vitro and in vivo assays with acetylsalicylic acid, at least not when the experiments were carried out with the doses normally used in human beings. (author)

  11. Electron impact ionization of large krypton clusters

    Institute of Scientific and Technical Information of China (English)

    Li Shao-Hui; Li Ru-Xin; Ni Guo-Quan; Xu Zhi-Zhan

    2004-01-01

    We show that the detection of ionization of very large van der Waals clusters in a pulsed jet or a beam can be realized by using a fast ion gauge. Rapid positive feedback electron impact ionization and fragmentation processes,which are initially ignited by electron impact ionization of the krypton clusters with the electron current of the ion gauge, result in the appearance of a progressional oscillation-like ion spectrum, or just of a single fast event under critical conditions. Each line in the spectrum represents a correlated explosion or avalanche ionization of the clusters.The phenomena have been analysed qualitatively along with a Rayleigh scattering experiment of the corresponding cluster jet.

  12. Evaluation of target power supplies for krypton storage in sputter-deposited metals

    International Nuclear Information System (INIS)

    Greenwell, E.N.; McClanahan, E.D.; Moss, R.W.

    1986-04-01

    Implantation of 85 Kr in a growing sputtered metal deposit has been studied for the containment of 85 Kr recovered from the reprocessing of spent nuclear fuel. PNL, as part of DOE's research program for 85 Kr storage, has developed krypton trapping storage devices (KTSDs) in a range of sizes for ''cold'' and radioactive testing. The KTSD is a stainless steel canister that contains a sputtering target for depositing an amorphous rare-earth transition metal on the inner wall and simultaneously implanting low-energy krypton ions in the growing deposit. This report covers the design requirements for the target power supply and the description, testing and evaluation of three basic designs. The designs chosen for evaluation were: (1) a standard commercial power supply with an external PNL-designed current interrupter, (2) a commercially manufactured power supply with an integral series-type interrupter, and (3) a commercially manufactured power supply with an integral shunt-type interrupter. The units were compared on the basis of performance, reliability, and life-cycle cost. 8 refs., 9 figs., 2 tabs

  13. Technetium tc 99m-labeled red blood cells in the preoperative diagnosis of cavernous hemangioma and other vascular orbital tumors.

    Science.gov (United States)

    Polito, Ennio; Burroni, Luca; Pichierri, Patrizia; Loffredo, Antonio; Vattimo, Angelo G

    2005-12-01

    To evaluate technetium Tc 99m (99mTc) red blood cell scintigraphy as a diagnostic tool for orbital cavernous hemangioma and to differentiate between orbital masses on the basis of their vascularization. We performed 99mTc red blood cell scintigraphy on 23 patients (8 female and 15 male; mean age, 47 years) affected by an orbital mass previously revealed with computed tomography (CT) and magnetic resonance imaging (MRI) and suggesting cavernous hemangioma. In our diagnosis, we considered the orbital increase delayed uptake with the typical scintigraphic pattern known as perfusion blood pool mismatch. The patients underwent biopsy or surgical treatment with transconjunctival cryosurgical extraction when possible. Single-photon emission tomography (SPET) showed intense focal uptake in the orbit corresponding to radiologic findings in 11 patients who underwent surgical treatment and pathologic evaluation (9 cavernous hemangiomas, 1 hemangiopericytoma, and 1 lymphangioma). Clinical or histologic examination of the remaining 22 patients revealed the presence of 5 lymphoid pseudotumors, 2 lymphomas, 2 pleomorphic adenomas of the lacrimal gland, 1 astrocytoma, 1 ophthalmic vein thrombosis, and 1 orbital varix. The confirmation of the preoperative diagnosis by 99mTc red blood cell scintigraphy shows that this technique is a reliable tool for differentiating cavernous hemangiomas from other orbital masses (sensitivity, 100%; specificity, 86%) when ultrasound, CT, and MRI are not diagnostic. Unfortunately, 99mTc red blood cell scintigraphy results were positive in 1 patient with hemangiopericytoma and 1 patient with lymphangioma, which showed increased uptake in the lesion on SPET images because of the vascular nature of these tumors. Therefore, in these cases, the SPET images have to be integrated with data regarding clinical preoperative evaluation and CT scans or MRI studies. On the basis of our study, a complete diagnostic picture, CT scans or MRI studies, and

  14. Phase transitions in the argon, krypton and xenon in generalized Van der Waals theory

    International Nuclear Information System (INIS)

    Cavalcanti, H.M.

    1977-01-01

    Fluid-solid like phase transitions for three monoatomic substances, argon, krypton and xenon are treated, using the extension of the Van der Waals theory to the crystalline state. The method utilized is based on 'Maxwell construction' of identical areas [pt

  15. Labelling of red blood cells with 99m pertechnetate

    International Nuclear Information System (INIS)

    Vyth, A.; Raam, C.F.

    1979-07-01

    This paper describes a method for labelling red blood cells with 99mTc in vitro, using electrolytically generated stannous ions as the reducing agent for 99mTc-pertechnetate. A labelling of 95% was found. A method for the in vivo labelling of red blood cells is also reported. This involves an injection of a stanno-DTPA-complex followed 20 minutes later by a 99mTc-pertechnetate solution scintillation camera images show more background activity when the in vivo method of labelling is used

  16. The absolute photoionization cross sections of helium, neon, argon and krypton in the extreme vacuum ultraviolet region of the spectrum

    International Nuclear Information System (INIS)

    West, J.B.; Marr, G.V.

    1976-01-01

    An experiment has been set up at the Daresbury Synchrotron Radiation Facility to make absolute absorption cross section measurements over a wide range of photon energies. New data are reported for helium, neon, argon and krypton over the range 340 to 40 A which are believed to be reliable to +- 5%. A critical evaluation of published cross section data has been carried out to produce best value data from the ionization thresholds throughout the vacuum ultraviolet and x-ray region. Agreement with theoretical calculations on helium is demonstrated to be within +- 2 to 3% from threshold down to the double ionization threshold at 79 eV. Comparison with recent calculations of photoionization cross sections has shown that the effect of electron correlations is significant for the heavier inert gases. Contrary to previous claims, the position of the M shell maximum in krypton is located at 184 +- 10 eV in good agreement with r.p.a.e. calculations. Oscillator strength sum rules have been examined and their moments calculated. Discrepancies developing towards the heavier inert gases suggests a decrease in polarizabilities and other atomic factors from those predicted by Hartree-Fock calculations. (author)

  17. Nuclear Data Sheets for A = 81

    International Nuclear Information System (INIS)

    Baglin, Coral M.

    2008-01-01

    Nuclear structure data pertaining to all nuclei with mass number A = 81 (Zn, Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb) have been compiled and evaluated and incorporated into the ENSDF data file. This publication for A = 81 supersedes the previous publication (Coral M. Baglin, Nuclear Data Sheets79, 447 (1996), literature cutoff 1 November 1996) and the subsequent updates by C. Baglin for 81 Y (literature cutoff 8 October 1998) and 81 Zr (literature cutoff 24 March 2000). All literature available prior to 15 August 2008 has been considered. Subsequent to previous A = 81 evaluations, excited states have been reported for the first time in 81 Ga, and knowledge of excited state properties for 81 Y and 81 Zr has been significantly expanded. However, the expected ε+β + decay of 81 Zr has yet to be studied

  18. Use of krypton laser stimulation in the treatment of dry eye syndrome

    Science.gov (United States)

    Kecik, Tadeusz; Switka-Wieclawska, Iwona; Ciszewska, Joanna; Portacha, Lidia

    1991-08-01

    We''d like to present the use of krypton laser stimulation in the treatment of dry eye syndrom. 10 patients with dry eye syndrom were treated with irradiation of the lacrimal gland. Schirmer test and break up time were performed before and after therapy. After 10 days of treatment we observed higher value of secreted tear amount.

  19. In vivo red blood cell compatibility testing using indium-113m tropolone-labeled red blood cells

    International Nuclear Information System (INIS)

    Morrissey, G.J.; Gravelle, D.; Dietz, G.; Driedger, A.A.; King, M.; Cradduck, T.D.

    1988-01-01

    In vivo radionuclide crossmatch is a method for identifying compatible blood for transfusion when allo- or autoantibodies preclude the use of conventional crossmatching techniques. A technique for labeling small volumes of donor red blood cells with [/sup 113m/In]tropolone is reported. The use of /sup 113m/In minimizes the accumulation of background radioactivity and the radiation dose especially so when multiple crossmatches are performed. Labeling red cells with [/sup 113m/In]tropolone is faster and easier to perform than with other radionuclides. Consistently high labeling efficiencies are obtained and minimal /sup 113m/In activity elutes from the labeled red blood cells. A case study involving 22 crossmatches is presented to demonstrate the technique. The radiation dose equivalent from /sup 113m/In is significantly less than with other radionuclides that may be used to label red cells

  20. Supershort avalanche electron beam in SF_{6} and krypton

    Directory of Open Access Journals (Sweden)

    Cheng Zhang (章程

    2016-03-01

    Full Text Available Runaway electrons play an important role in the avalanche formation in nanosecond- and subnanosecond- pulse discharges. In this paper, characteristics of a supershort avalanche electron beam (SAEB generated at the subnanosecond and nanosecond breakdown in sulfur hexafluoride (SF_{6} in an inhomogeneous electric field were studied. One pulser operated at negative polarity with voltage pulse amplitude of ∼130  kV and rise time of 0.3 ns. The other pulser operated at negative polarity with voltage pulse amplitude of 70 kV and rise time of ∼1.6  ns. SAEB parameters in SF_{6} are compared with those obtained in krypton (Kr, nitrogen (N_{2}, air, and mixtures of SF_{6} with krypton or nitrogen. Experimental results showed that SAEB currents appeared during the rise-time of the voltage pulse for both pulsers. Moreover, amplitudes of the SAEB current in SF_{6} and Kr approximately ranged from several to tens of milliamps at atmospheric pressure, which were smaller than those in N_{2} and air (ranging from hundreds of milliamps to several amperes. Furthermore, the concentration of SF_{6} additive could significantly reduce the SAEB current in N_{2}-SF_{6} mixture, but it slightly affected the SAEB current in Kr-SF_{6} mixture because of the atomic/molecular ionization cross section of the gas had a much greater impact on the SAEB current rather than the electronegativity.

  1. Long-term storage of compressed radioactive krypton in cylinders

    International Nuclear Information System (INIS)

    Niephaus, D.; Nommensen, O.; Bruecher, H.

    1982-01-01

    The recommendations of the German Radiation Protection Commission necessitate the separation of the radioactive noble gas krypton-85 (Kr-85) produced in large LWR reprocessing plants from the dissolver off-gas. A possible method of removal is a long-term storage of the compressed noble gas above ground in cylinders. The aim of the present study is to develop such a storage concept and evaluate its feasibility under the aspects of safety and cost. After having been filled, the gas cylinders are placed separately into transport racks serving to protect the cylinders. Following this, the cylinders are transferred out of the filling station in a transport cask, conveyed to the storage building and stored there. The storage building protects the gas cylinders against external impacts. The storage cells constitute a second barrier against the release of Kr-85. The heat produced during decay of the Kr-85 in the gas cylinders is carried off by natural convection of the air circulating in the storage cells. To study possible corrosion attack on special steels due to rubidium, experiments were conducted at 200 0 C during test periods up to 3500h. In order to compare properties at elevated temperatures, corrosion experiments were conducted at 500 0 C, which is far above the maximum licensed storage temperature of 200 0 C. Experiments were conducted concerning the adsorption of krypton on various adsorbents, thus reducing the pressure inside the gas cylinder during storage. A cost estimate based on 1980 prices

  2. Right-sided phase abnormalities on gated blood pool ventriculography: Demonstration of six different patterns

    International Nuclear Information System (INIS)

    Bahar, R.H.; Abdel-Dayem, H.M.; Ziada, G.; Al-Suhali, A.; Constantinides, C.; Nair, K.M.

    1986-01-01

    Phase pattern abnormalities on multiple gated blood pool ventriculography are better reported for the left ventricle (LV) than for the right side of the heart. In a study of 92 patients who also underwent contrast ventriculography, the authors identified six different patterns of right-sided phase abnormalities and their causes: right bundle-branch block, causing delayed phase in the entire right ventricle (RV); ischemic right coronary artery disease, causing delayed phase in the inferior RV wall; pericardial effusion, causing an L-shaped area of delayed phase to the right of the septum and below the LV; pulmonary hypertension, causing delayed phase in the pulmonary infundibulum; tricuspid regurgitation, causing a crescentic area of delayed phase around and below the right RV and extending below the LV as well, and atrial septal defect causing an abnormally large auricular phase

  3. Alternative male reproductive tactics and the immunocompetence handicap in the Azorean rock-pool blenny, Parablennius parvicornis

    Science.gov (United States)

    Ros, Albert F.H; Bouton, Niels; Santos, Ricardo S; Oliveira, Rui F

    2006-01-01

    In the Azorean rock-pool blenny (Parablennius parvicornis) reproductively active males display alternative morphotypes, which differ in the expression of secondary sexual characters (SSC). Males expressing SSC, the M+ morphotype, have high androgen levels and compete for crevices that will be visited by females to spawn. M+ males holding nests court females and care for the eggs. Males with low expression of SSC, the M− morphotype, have low levels of androgens and reproduce by stealing fertilizations from the M+ males. Based on the hypothesis that androgens are immunosuppressive, we expected these morphotypes to differ in immunocompetence. To test this hypothesis, we conducted a field study in which we collected repeated blood samples to monitor leukocyte populations (blood smears), and to measure the primary antibody response of males that were experimentally challenged with a foreign non-pathogenic antigen (sheep red blood cells). Circulating levels of 11-ketotestosterone and testosterone were higher in M+ males than in M− males. Neither granulocyte nor thrombocyte counts did covariate with androgens or male tactic. In contrast, lymphocyte counts and humoral antibody response were negatively correlated with body size, and as expected, both were lower in M+ than in M− males. Interestingly, in M+ males androgen levels decreased after immunization, and this was less in nest-holder males than in M+ males that were floating around in the pools. Within each morphotype we found no relationship between androgens and immunocompetence. The latter result is not supportive for androgen regulated immunosuppression in M+ males. A possible alternative is enhancement of immunity in M− males. These males had relatively high levels of injuries in comparison with M+ males. High immunity might be a consequence of high infection rate because of such injuries. PMID:16627274

  4. Evaluation of right cardiac function with sup(81m)Kr

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Kotsuka, Takahiro [National Cardiovascular Center, Suita, Osaka (Japan)

    1982-10-01

    Right cardiac function was evaluated by a first-pass method of repeated rapid injections of sup(81m)Kr, and by a multigated scanning of continuous injections using a scinticamera and a computer system. Right ventricular ejection fraction (RVEF) was rather low in the ascending course of time-activity curve and rather high in the descending course by the use of rapid injection. The RVEF estimated by the rapid injection method was relatively high in ischemic heart disease; but the figure was a little changed in tricuspid insufficiency, especially in the case with high reflux, showing no effect of rapid injection. There was a good correlation between the result of rapid injection and that of the sup(99m)Tc-first-pass method. Clinically, a little increase in RVEF due to exercise was observed in a group of right coronary artery obstruction, and in all the cases of tricuspid insufficiency changes in RVEF due to exercise was in good accordance with the result of classification of severity of the disease. Accuracy in RVEF estimated by the rapid injection method was correlated with that of multi-gated scanning. In continuous observation of right cardiac function by the continuous injection method, decreased RVEF following exercise was noted in cases of inferior wall infarction with atrial fibrillation, compared with the RVEF in cases of anterior wall infarction with normal right coronary arteries.

  5. Evaluation of right cardiac fuction with sup(81m)Kr

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Kotsuka, Takahiro

    1982-01-01

    Right cardiac function was evaluated by a first-pass method of repeated rapid injections of sup(81m)Kr, and by a multigated scanning of continuous injections using a scinticamera and a computer system. Right ventricular ejection fraction (RVEF) was rather low in the ascending course of time-activity curve and rather high in the descending course by the use of rapid injection. The RVEF estimated by the rapid injection method was relatively high in ischemic heart disease; but the figure was a little changed in tricuspid insufficiency, especially in the case with high reflux, showing no effect of rapid injection. There was a good correlation between the result of rapid injection and that of the sup(99m)Tc-first-pass method. Clinically, a little increase in RVEF due to exercise was observed in a group of right coronary artery obstruction, and in all the cases of tricuspid insufficiency changes in RVEF due to exercise was in good accordance with the result of classification of severity of the disease. Accuracy in RVEF estimated by the rapid injection method was correlated with that of multi-gated scanning. In continuous observation of right cardiac function by the continuous injection method, decreased RVEF following exercise was noted in cases of inferior wall infarction with atrial fibrillation, compared with the RVEF in cases of anterior wall infarction with normal right coronary arteries. (Ueda, J.)

  6. Environmental controls of C, N and P biogeochemistry in peatland pools.

    Science.gov (United States)

    Arsenault, Julien; Talbot, Julie; Moore, Tim R

    2018-08-01

    Pools are common in northern peatlands but studies have seldom focused on their nutrient biogeochemistry, especially in relation to their morphological characteristics and through seasons. We determined the environmental characteristics controlling carbon (C), nitrogen (N) and phosphorus (P) biogeochemistry in pools and assessed their evolution over the course of the 2016 growing season in a subboreal ombrotrophic peatland of eastern Canada. We showed that water chemistry variations in 62 pools were significantly explained by depth (81.9%) and the surrounding vegetation type (14.8%), but not by pool area or shape. Shallow pools had larger dissolved organic carbon (DOC) and total nitrogen (TN) concentrations and lower pH than deep pools, while pools surrounded by coniferous trees had more recalcitrant DOC than pools where vegetation was dominated by mosses. The influence of depth on pool biogeochemistry was confirmed by the seasonal survey of pools of different sizes with 47.1% of the variation in pool water chemistry over time significantly explained. Of this, 67.3% was explained by the interaction between time and pool size and 32.7% by pool size alone. P concentrations were small in all pools all summer long and combined with high N:P ratios, are indicative of P-limitation. Our results show that pool biogeochemistry is influenced by internal processes and highlight the spatial and temporal heterogeneity of nutrient biogeochemistry in ombrotrophic peatlands. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Depletion of NAD pool contributes to impairment of endothelial progenitor cell mobilization in diabetes.

    Science.gov (United States)

    Wang, Pei; Yang, Xi; Zhang, Zheng; Song, Jie; Guan, Yun-Feng; Zou, Da-Jin; Miao, Chao-Yu

    2016-06-01

    The impaired mobilization of endothelial progenitor cells (EPCs) from bone marrow (BM) critically contributes to the diabetes-associated vascular complications. Here, we investigated the relationship between the nicotinamide phosphoribosyltransferase (NAMPT)-controlled nicotinamide adenine dinucleotide (NAD) metabolism and the impaired mobilization of BM-derived EPCs in diabetic condition. The NAMPT-NAD pool in BM and BM-derived EPCs in wild-type (WT) and diabetic db/db mice was determined. Nicotinamide, a natural substrate for NAD biosynthesis, was administrated for 2weeks in db/db mice to examine the influence of enhancing NAD pool on BM and blood EPCs number. The modulations of stromal cell-derived factor-1α (SDF-1α) and endothelial nitric oxide synthase (eNOS) protein in BM were measured using immunoblotting. The EPCs intracellular NAMPT level and NAD concentration, as well as the blood EPCs number, were compared between 9 healthy people and 16 patients with type 2 diabetes mellitus (T2DM). The T2DM patients were treated with nicotinamide for two weeks and then the blood EPCs number was determined. Moreover, the association between blood EPCs numbers and EPCs intracellular NAD(+)/NAMPT protein levels in 21 healthy individuals was determined. We found that NAD concentration and NAMPT expression in BM and BM-derived EPCs of db/db mice were significantly lower than those in WT mice BM. Enhancing NAD pool not only increased the EPCs intracellular NAD concentration and blood EPCs number, but also improved post-ischemic wound healing and blood reperfusion in db/db mice with hind-limb ischemia model. Enhancing NAD pool rescued the impaired modulations of stromal cell-derived factor-1α (SDF-1α) and endothelial nitric oxide synthase (eNOS) protein levels in db/db mice BM upon hind-limb ischemia. In addition, enhancing NAD pool significantly inhibited PARP and caspase-3 activates in db/db mice BM. The intracellular NAMPT-NAD pool was positively associated with blood

  8. California GAMA Special Study. Development of a Capability for the Analysis of Krypton-85 in Groundwater Samples

    Energy Technology Data Exchange (ETDEWEB)

    Visser, Ate [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bibby, Richard K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Moran, Jean E. [California State Univ. (CalState), Long Beach, CA (United States); Singleton, Michael J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Esser, Bradley K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-06-01

    A capability for the analysis of krypton-85 (85Kr) in groundwater samples was developed at LLNL. Samples are collected by extracting gas from 2000-4000 L of groundwater at the well, yielding approximately 0.2 cm3 STP krypton. Sample collection takes 1 to 4 hours. Krypton is purified in the laboratory using a combination of molecular sieve and activated charcoal traps, and transferred to a liquid scintillation vial. The 85Kr activity is measured by liquid scintillation on a Quantulus 1220 liquid scintillation counter from PerkinElmer. The detection limit for a typical 0.2 cm3Kr sample size is 11% of the present day activity in air, corresponding to the decay corrected activity in air in 1987. The typical measurement uncertainty is below 10% for recently recharged samples. Six groundwater samples were collected, purified and counted. 85Kr was not detected in any of the samples counted at LLNL. 85Kr was detected by the low level counting laboratory of Bern University in all samples between 1.5 and 6.6 decays per minute per cm3 krypton, corresponding to decay corrected activities in air between 1971 and 1985. The new capability is an excellent complement to tritium-helium, expanding the existing suite of age dating tools available to the GAMA program (35S, 3H/3He, 14C and radiogenic helium). 85Kr can replace 3H/3He in settings where 3H/3He ages are impossible to determine (for example where terrigenic helium overwhelms tritiogenic helium) and provides additional insight into travel time distributions in complex mixed groundwater systems.

  9. In situ measurements of krypton in xenon gas with a quadrupole mass spectrometer following a cold-trap at a temporarily reduced pumping speed

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Ethan; Rosendahl, Stephan; Huhmann, Christian; Kettling, Hans; Schlak, Martin; Weinheimer, Christian [Muenster Univ. (Germany). Inst. fuer Kernphysik

    2013-07-01

    Liquid xenon detectors have risen to be extremely competitive for dark matter and neutrinoless double-beta decay searches. In order to achieve the required sensitivity, backgrounds must be reduced substantially. One important background is the beta-decay of {sup 85}Kr, which constitutes a uniform internal background in liquid xenon detectors. Cryogenic distillation can be used to reduce the krypton concentration to acceptable levels, but gas diagnostics become incredibly difficult at these ultra-pure levels. A new method for measuring the concentration of krypton in xenon has been developed, expanding on the existing technique of a cold trap and a Residual Gas Analyzer (RGA). By using a liquid nitrogen cold trap, one can take advantage of the difference in vapor pressures of krypton in xenon to freeze most of the xenon gas while allowing the krypton to pass to the measurement chamber. Here, only a few milliliters of xenon is expended in the measurement, while achieving a sensitivity of sub ppb (parts per billion). The key change is the use of a butterfly valve to partially close the opening in front of the turbomolecular pump, thereby reducing the effective pumping speed and enhancing the RGA signal.

  10. Relative efficacy of the argon green, argon blue-green, and krypton red lasers for 10-0 nylon subconjunctival laser suture lysis.

    Science.gov (United States)

    Mudgil, A V; To, K W; Balachandran, R M; Janigian, R H; Tsiaras, W G

    1999-01-01

    To determine the optimal wavelength for subconjunctival laser suture lysis. 130 black monofilament 10-0 nylon sutures were sewn subconjunctivally into the bare sclera of enucleated rabbit globes. The lowest energy levels facilitating laser suture lysis were determined for the argon green (514.5 NM), argon blue-green (488.0 NM, 514.5 NM), and krypton red (647.1 NM) wavelengths. In addition, absorption spectroscopy was performed on the suture material and conjunctiva using the Perkin Elmer W/VIS Lambda 2 spectrometer. Krypton red produced the fewest buttonhole defects, and it was also the most efficient energy source for suture lysis (P = 0.0001) under nontenectomized conjunctiva. Absorbance spectra studies revealed peak absorbance at 628 NM for the 10-0 nylon suture material. Based on animal and absorption spectroscopy studies, krypton red may be a safer and more efficient wavelength for subconjunctival laser suture lysis.

  11. Patterns of ventricular dysfunction in patients receiving cardiotoxic chemotherapy as assessed with gated blood pool imaging

    International Nuclear Information System (INIS)

    Spies, S.M.; Parikh, S.R.; Spies, W.G.; Zimmer, A.M.; Silverstein, E.A.

    1989-01-01

    Clinical concern over significant cardiotoxicity of commonly employed chemotherapeutic regimens is a common indication for gated blood pool imaging. The authors have undertaken a review of 102 patients referred for such evaluation during a 14-month period. Ventricular ejection fractions, cine displays, and phase analysis were performed on each patient study. Approximately one-third of the cases showed significant abnormalities in wall motion or global ejection fraction. Many abnormal cases had isolated left ventricular findings, while fewer had isolated right ventricular findings. Left ventricular wall motion abnormalities were often focal. The patterns of ventricular dysfunction in patients receiving cardiotoxic chemotherapy are diverse, and awareness of the various possibilities is important for accurate clinical assessment of these patients

  12. A study of the atmospheric dispersion of a high release of krypton-85 above a complex coastal terrain, comparison with the predictions of Gaussian models (Briggs, Doury, ADMS4).

    Science.gov (United States)

    Leroy, C; Maro, D; Hébert, D; Solier, L; Rozet, M; Le Cavelier, S; Connan, O

    2010-11-01

    Atmospheric releases of krypton-85, from the nuclear fuel reprocessing plant at the AREVA NC facility at La Hague (France), were used to test Gaussian models of dispersion. In 2001-2002, the French Institute for Radiological Protection and Nuclear Safety (IRSN) studied the atmospheric dispersion of 15 releases, using krypton-85 as a tracer for plumes emitted from two 100-m-high stacks. Krypton-85 is a chemically inert radionuclide. Krypton-85 air concentration measurements were performed on the ground in the downwind direction, at distances between 0.36 and 3.3 km from the release, by neutral or slightly unstable atmospheric conditions. The standard deviation for the horizontal dispersion of the plume and the Atmospheric Transfer Coefficient (ATC) were determined from these measurements. The experimental results were compared with calculations using first generation (Doury, Briggs) and second generation (ADMS 4.0) Gaussian models. The ADMS 4.0 model was used in two configurations; one takes account of the effect of the built-up area, and the other the effect of the roughness of the surface on the plume dispersion. Only the Briggs model correctly reproduced the measured values for the width of the plume, whereas the ADMS 4.0 model overestimated it and the Doury model underestimated it. The agreement of the models with measured values of the ATC varied according to distance from the release point. For distances less than 2 km from the release point, the ADMS 4.0 model achieved the best agreement between model and measurement; beyond this distance, the best agreement was achieved by the Briggs and Doury models.

  13. High-resolution blood-pool-contrast-enhanced MR angiography in glioblastoma: tumor-associated neovascularization as a biomarker for patient survival. A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Puig, Josep; Blasco, Gerard; Remollo, Sebastian; Hernandez, David; Pedraza, Salvador [Hospital Universitari Dr Josep Trueta, Research Unit of Diagnostic Imaging Institute (IDI), Department of Radiology [Girona Biomedical Research Institute] IDIBGI, Girona (Spain); Daunis-i-Estadella, Josep; Mateu, Gloria [University of Girona, Department of Computer Science, Applied Mathematics and Statistics, Girona (Spain); Alberich-Bayarri, Angel [La Fe Polytechnics and University Hospital, Biomedical Imaging Research Group (GIBI230), La Fe Health Research Institute, Valencia (Spain); Essig, Marco [University of Manitoba, Department of Radiology, Winnipeg (Canada); Jain, Rajan [NYU School of Medicine, Division of Neuroradiology, Department of Radiology, New York, NY (United States); Puigdemont, Montserrat [Hospital Universitari Dr Josep Trueta, Catalan Institute of Oncology (ICO), Hospital Cancer Registry, Girona (Spain); Sanchez-Gonzalez, Javier [Philips Healthcare Iberica, Madrid (Spain); Wintermark, Max [Stanford University, Department of Radiology, Neuroradiology Division, Palo Alto, CA (United States)

    2016-01-15

    The objective of the study was to determine whether tumor-associated neovascularization on high-resolution gadofosveset-enhanced magnetic resonance angiography (MRA) is a useful biomarker for predicting survival in patients with newly diagnosed glioblastomas. Before treatment, 35 patients (25 men; mean age, 64 ± 14 years) with glioblastoma underwent MRI including first-pass dynamic susceptibility contrast (DSC) perfusion and post-contrast T1WI sequences with gadobutrol (0.1 mmol/kg) and, 48 h later, high-resolution MRA with gadofosveset (0.03 mmol/kg). Volumes of interest for contrast-enhancing lesion (CEL), non-CEL, and contralateral normal-appearing white matter were obtained, and DSC perfusion and DWI parameters were evaluated. Prognostic factors were assessed by Kaplan-Meier survival and Cox proportional hazards model. Eighteen (51.42 %) glioblastomas were hypervascular on high-resolution MRA. Hypervascular glioblastomas were associated with higher CEL volume and lower Karnofsky score. Median survival rates for patients with hypovascular and hypervascular glioblastomas treated with surgery, radiotherapy, and chemotherapy were 15 and 9.75 months, respectively (P < 0.001). Tumor-associated neovascularization was the best predictor of survival at 5.25 months (AUC = 0.794, 81.2 % sensitivity, 77.8 % specificity, 76.5 % positive predictive value, 82.4 % negative predictive value) and yielded the highest hazard ratio (P < 0.001). Tumor-associated neovascularization detected on high-resolution blood-pool-contrast-enhanced MRA of newly diagnosed glioblastoma seems to be a useful biomarker that correlates with worse survival. (orig.)

  14. Adsorption and pore condensation of krypton on mesoporous silicas at 77 K

    Czech Academy of Sciences Publication Activity Database

    Zukal, Arnošt

    2006-01-01

    Roč. 92, 1-3 (2006), s. 220-226 ISSN 1387-1811 R&D Projects: GA ČR GA203/05/0197; GA MPO FT-TA/040 Institutional research plan: CEZ:AV0Z40400503 Keywords : adsorption of krypton at 77 K * capillary condensation * stability condition * restriction of mesopore filling Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.796, year: 2006

  15. Krypton-85 disposal program. Semiannual report, August 15, 1977--March 31, 1978

    International Nuclear Information System (INIS)

    Klett, R.D.

    1979-02-01

    The first 7.5 months of the Krypton-85 disposal program are summarized. Included are task definitions and initial progress in geologic disposal system studies, SURF compatibility, augmented heat dissipation, material qualification, exterior canister compatibility, ceramic liners for canisters, and geologic transport. Feasibility studies indicate that Kr-85 can be disposed of at SURF facility or in near-surface geologic repositories

  16. Development of the krypton absorption in liquid carbon dioxide (KALC) process for HTGR off-gas reprocessing

    International Nuclear Information System (INIS)

    Glass, R.W.; Beaujean, H.W.R.; Cochran, H.D. Jr.; Haas, P.A.; Levins, D.M.; Woods, W.M.

    1975-01-01

    Reprocessing of High-Temperature Gas-Cooled Reactor (HTGR) fuel involves burning of the graphite-matrix elements to release the fuel for recovery purposes. The resulting off-gas is primarily CO 2 with residual amounts of N 2 , O 2 , and CO, together with fission products. Trace quantities of krypton-85 must be recovered in a concentrated form from the gas stream, but processes commonly employed for rare gas removal and concentration are not suitable for use with off-gas from graphite burning. The KALC (Krypton Absorption in Liquid CO 2 ) process employs liquid CO 2 as a volatile solvent for the krypton and is, therefore, uniquely suited to the task. Engineering development of the KALC process is currently under way at the Oak Ridge National Laboratory (ORNL) and the Oak Ridge Gaseous Diffusion Plant (ORGDP). The ORNL system is designed for close study of the individual separation operations involved in the KALC process, while the ORGDP system provides a complete pilot facility for demonstrating combined operations on a somewhat larger scale. Packed column performance and process control procedures have been of prime importance in the initial studies. Computer programs have been prepared to analyze and model operational performance of the KALC studies, and special sampling and in-line monitoring systems have been developed for use in the experimental facilities. (U.S.)

  17. Process and apparatus for separating and recovering krypton-85 from exhaust gas of nuclear reactor or the like

    International Nuclear Information System (INIS)

    Yusa, H.; Kamiya, K.; Murata, T.; Yamaki, H.; Hisatomi, S.

    1975-01-01

    An apparatus is described for separating and recovering radioactive krypton-85 contained in an exhaust gas of a nuclear reactor or the like, which comprises a plurality of adsorption beds connected in parallel with respect to a passageway for the exhaust gas, each being packed with activated carbon, wherein adsorption and desorption of krypton-85 in each of the beds are alternatively and repeatedly performed by operating valves disposed between each of the beds and means for reducing pressure in the beds to be desorbed in accordance with a predetermined time schedule. The adsorption and concentration efficiencies are markedly increased by combining the above adsorption apparatus and a distillation apparatus

  18. Validation of curve-fitting method for blood retention of 99mTc-GSA. Comparison with blood sampling method

    International Nuclear Information System (INIS)

    Ha-Kawa, Sang Kil; Suga, Yutaka; Kouda, Katsuyasu; Ikeda, Koshi; Tanaka, Yoshimasa

    1997-01-01

    We investigated a curve-fitting method for the rate of blood retention of 99m Tc-galactosyl serum albumin (GSA) as a substitute for the blood sampling method. Seven healthy volunteers and 27 patients with liver disease underwent 99m Tc-GSA scanning. After normalization of the y-intercept as 100 percent, a biexponential regression curve for the precordial time-activity curve provided the percent injected dose (%ID) of 99m Tc-GSA in the blood without blood sampling. The discrepancy between %ID obtained by the curve-fitting method and that by the multiple blood samples was minimal in normal volunteers 3.1±2.1% (mean±standard deviation, n=77 sampling). Slightly greater discrepancy was observed in patients with liver disease (7.5±6.1%, n=135 sampling). The %ID at 15 min after injection obtained from the fitted curve was significantly greater in patients with liver cirrhosis than in the controls (53.2±11.6%, n=13; vs. 31.9±2.8%, n=7, p 99m Tc-GSA and the plasma retention rate for indocyanine green (r=-0.869, p 99m Tc-GSA and could be a substitute for the blood sampling method. (author)

  19. The Study of Reducing Krypton-85 Activity in Metal Halide Lamp%降低金卤灯内氪-85活度的研究

    Institute of Scientific and Technical Information of China (English)

    叶碧君

    2012-01-01

    通过测试及分析不同氪-85活度填充气体的同规格金卤灯的各项性能参数,研究了在确保金卤灯各项性能的前提下,降低金卤灯中氪-85活度的可行性及金卤灯中氪-85存在的必要性,可以为今后确定金卤灯中需添加的最低氪-85活度提供参考。%By analyzing the parameters of metal halide lamps which are filled with gas with different activity of krypton-85, the paper studies the feasibility of reducing krypton-85 activity in metal halide lamp while ensuring the lamp performance, and proves the necessity of its existence of krypton-85 in metal halide lamp. it can provide us a reference to determine the minimum krypton-85 activity to he added in metal halide lamps.

  20. Radiokrypton dating coming of age

    Institute of Scientific and Technical Information of China (English)

    Zheng-Tian Lu

    2016-01-01

    The dream of radiokrypton dating began in 1969 when Heinz Hugo Loosli and Hans Oeschger of the University of Bern first detected the decay of81Rr(half-life=230 000 yr)in krypton gas extracted from air[1].This isotope is produced in the upper atmosphere by cosmic-ray-induced spallation and neutron-activation of stable krypton.Due to its long residence time(105 yr)in the atmosphere,81Rr is uniformly