WorldWideScience

Sample records for ionotron device equipped

  1. Preface for Special Topic: Ionotronics

    Directory of Open Access Journals (Sweden)

    Dillon D. Fong

    2017-04-01

    Full Text Available Ionotronics is an emerging technology that exploits the coupled ionic and electronic character of materials, including the profound modifications of structure, composition, and properties achievable through external fields. While the geometry of the device and the medium of the electric field can vary, a key commonality is the importance of interfaces and the ability of ions to move along and across them. As the electronic conductivity of many metal oxides can change significantly with the oxygen vacancy concentration, understanding defect formation and migration in such materials has been the focus of many recent studies, particularly for correlated electron systems. However, the incorporation of small ions such as hydrogen or lithium can be equally or more effective depending on the material and its interface: the key is whether or not the process can be fully reversed over many cycles without interfacial degradation (much like for energy storage systems. For most device applications, the switching process should require low power and take place at high speeds, even at room temperature.

  2. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  3. Special Equipment and/or Devices.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    This standard covers the sanitation requirements for equipment and/or devices used in the storage, preparation, or handling of foods and beverages. The National Sanitation Foundation's basic criteria for the evaluation of special equipment and/or devices has been prepared to fulfill several specific needs, its major function being to serve as a…

  4. 30 CFR 77.410 - Mobile equipment; automatic warning devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mobile equipment; automatic warning devices. 77... UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.410 Mobile equipment; automatic warning devices. (a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except...

  5. Three equipment concepts for the Fusion Engineering Device

    International Nuclear Information System (INIS)

    Spampinato, P.T.; Masson, L.S.; Watts, K.D.; Grant, N.R.; Kuban, D.P.

    1982-01-01

    Maintenance equipment which is needed to remotely handle fusion device components is being conceptually developed for the Fusion Engineering Design Center. This will test the assumption that these equipment needs can be satisfied by present technology. In addition, the development of equipment conceptual designs will allow for cost estimates which have a much higher degree of certainty. Accurate equipment costs will be useful for assessments which trade off gains in availability as a function of increased investments in maintenance equipment

  6. Development of superconducting equipment for fusion device

    International Nuclear Information System (INIS)

    Konno, Masayuki; Ueda, Toshio; Hiue, Hisaaki; Ohgushi, Kouzou

    1993-01-01

    At Fuji Electric Co., Ltd., the development of superconductivity was started from 1960, and superconducting equipment for fusion device has been developed for ten years. The superconducting equipment, which is developed for fusion by Fuji Electric Co., Ltd., are able to be grouped in three categories which are current lead, superconducting coil and superconducting bus-line. The current lead is an electrical feeder between a superconducting coil and an electrical power supply. The rated current of developed current lead is 30kA at continuous use and 100kA at short time use respectively. The advanced disk type coil is developed for the toroidal field coil and some coils are developed for critical current measurement. Superconductor is applied to the superconducting bus-line between the superconducting coils and the current leads, and the bus-line is being developed for the Large Helical Device. This report describes an abstract of these equipment. (author)

  7. Management information system of medical equipment using mobile devices

    Science.gov (United States)

    Núñez, C.; Castro, D.

    2011-09-01

    The large numbers of technologies currently incorporated into mobile devices transform them into excellent tools for capture and to manage the information, because of the increasing computing power and storage that allow to add many miscellaneous applications. In order to obtain benefits of these technologies, in the biomedical engineering field, it was developed a mobile information system for medical equipment management. The central platform for the system it's a mobile phone, which by a connection with a web server, it's capable to send and receive information relative to any medical equipment. Decoding a type of barcodes, known as QR-Codes, the management process is simplified and improved. These barcodes identified the medical equipments in a database, when these codes are photographed and decoded with the mobile device, you can access to relevant information about the medical equipment in question. This Project in it's actual state is a basic support tool for the maintenance of medical equipment. It is also a modern alternative, competitive and economic in the actual market.

  8. Device for diagnoising abnormalities of equipments

    International Nuclear Information System (INIS)

    Nakano, Hiroshi.

    1986-01-01

    Purpose: To measure the collision energy easily and at high accuracy by applying impact shocks at known collision energy from a simulated acoustic wave generator and using the generated acoustic signal as reference data. Constitution: A plurality of acoustic detectors are attached to the surface of a nuclear reactor pressure vessel. These acoustic detectors are connected respectively to an abnormality diagnosis device for equipments. Then, when metal obstacles collide against the inner surface of the reactor pressure vessel, acoustic signals generated upon collision are detected by the acoustic detectors and acoustic information thus obtained from the acoustic detectors determines the colliding position of the metal obstacles by means of the abnormality diagnosis device and then the collision energy is measured. In this case, by applying impact shocks at known collision energy near the colliding position of metal obstacles determined by the abnormality diagnosis device, collision energy can be determined at a higher accuracy. (Kawakami, Y.)

  9. System constitution of plasma high frequency heating device and element equipment

    International Nuclear Information System (INIS)

    Nagashima, Takashi

    1988-01-01

    On the high frequency heating device used for nuclear fusion experiment, the system constitution and the main items of development for the element equipment are described. As for the high frequency heating device, large technical progress was observed in the past 10 years as the second stage heating for tokamaks and one of the main means of current drive. At present, three frequency zones are regarded as promising for plasma high frequency heating in large nuclear fusion devices, and the experiment of 10 MW class is in progress at JT-60, JET and so on. There are electron cyclotron heating, lower hybrid resonance frequency heating and ion cyclotron range of frquency heating. The basic constitution of these heating devices includes a high frequency source, a transmission system, a connection system, and a common system for control, cooling, record and others. The ECH device using gyrotrons of several tens GHz, the LHRF heating device using large power klystrons up to several GHz and the ICRF heating device up to 200 MHz are briefly explained. The main element equipments composing the high frequency heating systems of several tens MW are discussed. (Kako, I.)

  10. Electronic equipment and software for device 'FAZA'

    International Nuclear Information System (INIS)

    Avdeev, S.P.; Karnaukhov, V.A.; Kuznetsov, V.D.; Petrov, L.A.; Oeschler, H.; Lips, F.; Bart, R.

    1992-01-01

    Electronic equipment and software for the device FAZA are described. The device, designed for studying the nuclear multifragmentation process, consists of 5 time-of-flight telescopes, a position-sensitive avalanche chamber and 58 PM tubes. The time resolution of the time-of-flight telescopes is 0.5 ns, which allows a velocity resolution of 1.5%. The spatial resolution of the large avalanche counter is 4 mm, which allows angular resolution of 1 deg. Analogue signals from each PM tube come to two ADCs, to which strobes are supplied with a 400 ns shift. It allows codes corresponding to Cherenkov radiation and deexcitation of CsJ(Tl) to be distinguished in a two-dimensional plot. 8 refs.; 2 figs

  11. Inquiry about the uses of special equipment (CT equipment, angiography systems, mammography devices, screens)

    International Nuclear Information System (INIS)

    Schwager, P.; Stieve, F.E.

    1986-01-01

    There are at least 1100 special devices in medical establishment in Bavaria which require special inspection and surveillance with regard to quality of equipment and radiation protection. In addition, there are at least 53 tomographs available for operation, and at least 120 installed X-ray screens. These devices need special approval testing and quality control services as they contribute a very significant amount of the medically indicated radiation exposure of the population. Appropriate measures are explained that can be applied in order to reduce the medical radiation exposure to an optimum. (orig.) [de

  12. Clothing, equipment and devices for personnel protection: Its selection according to occupational risks

    International Nuclear Information System (INIS)

    1989-01-01

    This Venezuelan standard establishes the selection of the type of clothing, equipment and devices for personnel protection, to be used by workers according to the occupational risk they deal with, in order to avoid or to reduce the factors that can, directly or indirectly, affect their physical integrity. For the risks not contemplated in this norm, the selection of the type of clothing, equipment and devices for personnel protection, must be done following the corresponding international standard [es

  13. Failure diagnosis aiding device for plant equipment

    International Nuclear Information System (INIS)

    Uhara, Yoshihiko.

    1990-01-01

    The present invention intends to improve the efficiency of trouble shooting for equipments of industrial plants such as nuclear power plants. The device of the present invention comprises an intelligence base and an inference mechanism base. The intelligence base comprises a rule base, an information storing section having a part frame and a working frame and a user's frame. The parts frame contains the failure rate on every parts and data on related operations. The working frame contains the importance and frequency of working. The user's frame contains parameters showing the extent of user's skills. The rule base, the parts frame and the working frame can be selected in accordance with the extent of the user's skill in the inference mechanism. With such a constitution, failures can be checked with the intelligence base in accordance with the knowledges for the failures of the equipments and the extent of user's skill by way of the inference mechanism. (I.S.)

  14. Department of Thermonuclear Research annual report 1990

    Energy Technology Data Exchange (ETDEWEB)

    Sadowski, M [ed.

    1991-03-01

    Department of Thermonuclear Research Annual Report 1990 presents the most important results of theoretical, experimental, and technological studies, carried out within a framework of two programs: Diagnostics of High-Temperature Plasma (CPBP 01.10) and Nuclear Technology (CPBR 5.8). Theoretical studies of tokamak edge plasmas, charged particle motions, strong refraction effects, current pulse generators, classical models of atomic collisions, and electron mechanisms of the Coulomb barrier tunneling, are shortly summarized. Experimental studies of X-ray, ion, and proton emission from the RPI-type devices, as well as optimization tests and electron beam measurements at the PF-type facilities, are described. Technological studies of opto-electronic transmission systems, modifications of diagnostic equipment, design and construction of new PF facilities, as well as applications of the IONOTRON-type devices, are also presented. (author). 56 refs, 20 figs.

  15. Department of Thermonuclear Research annual report 1990

    International Nuclear Information System (INIS)

    Sadowski, M.

    1991-03-01

    Department of Thermonuclear Research Annual Report 1990 presents the most important results of theoretical, experimental, and technological studies, carried out within a framework of two programs: Diagnostics of High-Temperature Plasma (CPBP 01.10) and Nuclear Technology (CPBR 5.8). Theoretical studies of tokamak edge plasmas, charged particle motions, strong refraction effects, current pulse generators, classical models of atomic collisions, and electron mechanisms of the Coulomb barrier tunneling, are shortly summarized. Experimental studies of X-ray, ion, and proton emission from the RPI-type devices, as well as optimization tests and electron beam measurements at the PF-type facilities, are described. Technological studies of opto-electronic transmission systems, modifications of diagnostic equipment, design and construction of new PF facilities, as well as applications of the IONOTRON-type devices, are also presented. (author). 56 refs, 20 figs

  16. Design and fabrication of equipment and devices for a Radiotherapy department

    International Nuclear Information System (INIS)

    Picon, C.L.; Zaharia B, M.

    1998-01-01

    The objective of this work is to present the possibility to design and construct utilizing local technology, a series of equipment and devices necessaries for a routine in a Radiotherapy Department with typical budget in the Latin-American hospitals. (Author)

  17. Department of Thermonuclear Research annual report 1992

    International Nuclear Information System (INIS)

    Sadowski, M.; Pawlowicz, W.

    1993-02-01

    Department of Thermonuclear Research annual report 1992 presents the most important results of theoretical, experimental and technological studies carried out within a framework of the research program - Plasma Physics and an additional grant - Study of Surface Melting of Selected Materials with a Plasma stream (contract with the Committee for Scientific Research - KBN). Theoretical studies of tokamak edge plasmas, atomic collisions, heat transfer, and numerical codes, are shortly summarized. Experimental studies of X-rays and particles emitted from Plasma-Focus facilities, calibration of nuclear track detectors, optimization of PF discharges with additional gas targets, magnetic probe measurements, new diagnostic and experimental arrangements, as well as mass- and energy-analysis of ions from IONOTRON-type devices, are described. Also presented are technological studies, modernization of experimental facilities, design of new control systems, tests on uniformity and reproducibility of plasma streams as the formation of photovoltaic cells and modifications of solid surfaces by means of plasma streams from the IONOTRON and PF devices. (author)

  18. Department of Thermonuclear Research annual report 1992

    Energy Technology Data Exchange (ETDEWEB)

    Sadowski, M; Pawlowicz, W [eds.; Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

    1993-02-01

    Department of Thermonuclear Research annual report 1992 presents the most important results of theoretical, experimental and technological studies carried out within a framework of the research program - Plasma Physics and an additional grant - Study of Surface Melting of Selected Materials with a Plasma stream (contract with the Committee for Scientific Research - KBN). Theoretical studies of tokamak edge plasmas, atomic collisions, heat transfer, and numerical codes, are shortly summarized. Experimental studies of X-rays and particles emitted from Plasma-Focus facilities, calibration of nuclear track detectors, optimization of PF discharges with additional gas targets, magnetic probe measurements, new diagnostic and experimental arrangements, as well as mass- and energy-analysis of ions from IONOTRON-type devices, are described. Also presented are technological studies, modernization of experimental facilities, design of new control systems, tests on uniformity and reproducibility of plasma streams as the formation of photovoltaic cells and modifications of solid surfaces by means of plasma streams from the IONOTRON and PF devices. (author).

  19. 48 CFR 252.239-7016 - Telecommunications security equipment, devices, techniques, and services.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Telecommunications... SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.239-7016 Telecommunications... clause: Telecommunications Security Equipment, Devices, Techniques, and Services (DEC 1991) (a...

  20. Novel AC Servo Rotating and Linear Composite Driving Device for Plastic Forming Equipment

    Science.gov (United States)

    Liang, Jin-Tao; Zhao, Sheng-Dun; Li, Yong-Yi; Zhu, Mu-Zhi

    2017-07-01

    The existing plastic forming equipment are mostly driven by traditional AC motors with long transmission chains, low efficiency, large size, low precision and poor dynamic response are the common disadvantages. In order to realize high performance forming processes, the driving device should be improved, especially for complicated processing motions. Based on electric servo direct drive technology, a novel AC servo rotating and linear composite driving device is proposed, which features implementing both spindle rotation and feed motion without transmission, so that compact structure and precise control can be achieved. Flux switching topology is employed in the rotating drive component for strong robustness, and fractional slot is employed in the linear direct drive component for large force capability. Then the mechanical structure for compositing rotation and linear motion is designed. A device prototype is manufactured, machining of each component and the whole assembly are presented respectively. Commercial servo amplifiers are utilized to construct the control system of the proposed device. To validate the effectiveness of the proposed composite driving device, experimental study on the dynamic test benches are conducted. The results indicate that the output torque can attain to 420 N·m and the dynamic tracking errors are less than about 0.3 rad in the rotating drive. the dynamic tracking errors are less than about 1.6 mm in the linear feed. The proposed research provides a method to construct high efficiency and accuracy direct driving device in plastic forming equipment.

  1. Inspection device for buried equipment

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1994-01-01

    In an inspection device for a buried equipment, a rail is suspended at the upper portion of a vessel of a pit-vessel type pump buried in a plant building floor, and a truck movable vertical in the vessel along the rail, and an ultrasonic wave probe contained in the truck and urged to the vessel by an electromagnet are disposed. In addition, an elevator moving vertically along a shaft is disposed, and an arm having the ultrasonic probe disposed at the end portion and driven by a piston are disposed to the elevator. The ultrasonic wave probe moves vertically together with the truck along the rail in the vessel while being urged to the vessel by the electromagnet to inspect and measure the state at the inner and outer surfaces of the vessel. Further, the length of the arm is controlled so as to set a predetermined distance between the ultrasonic wave probe and the vessel. Subsequently, the elevator is moved vertically along a shaft passing through a shaft hole of a mount, and the shaft is rotated thereby enabling to inspect and measure the state of the inner and outer surfaces of the vessel. (N.H.)

  2. Department of Thermonuclear Research annual report 1989

    International Nuclear Information System (INIS)

    Sadowski, M.

    1990-02-01

    The report presents a review of theoretical, experimental and technological studies performed within a framework of three research programs: Diagnostics of High-Temperature Plasma (CPBP 01.10), Cold Fusion (CPBP-CF) and Nuclear Technology (CPBR 5.8). Theoretical investigations of a tokamak edge plasma, filamentary current structures and cold-fusion processes, are shortly described. Experimental studies of discharges in the RPI- and PF-type facilities as well as investigations of the interaction of ion-plasma streams with gaseous targets are summarized. Development of plasma diagnostic equipment and search for neutrons from cold-fusion processes are described. Technological studies of opto-electronic and high-voltage systems as well as use of IONOTRON-type devices for the ion implantation of semiconductors and the surface modification of solids are also presented. (author)

  3. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  4. Visual communication and terminal equipment

    International Nuclear Information System (INIS)

    Kang, Cheol Hui

    1988-06-01

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  5. Visual communication and terminal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Cheol Hui

    1988-06-15

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  6. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment

    International Nuclear Information System (INIS)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S.

    2017-01-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden

  7. The design of an energy harvesting device for prolonging the working time of DC equipment

    Science.gov (United States)

    Wen, Yayuan; Deng, Huaxia; Zhang, Jin; Yu, Liandong

    2016-01-01

    Energy harvesting (EH) derives from the idea of converting the ambient energy into electric energy, which can solve the problem of DC supply for some electronic equipment. PZT is a typical piezoelectric material of inorganic, which has been developed as EH devices to transfer ambient vibration energy into electric energy. However, these PZT devices require relatively violent excitation, and easy to be fatigue fracture under the resonance condition. In this paper, PVDF, which is a kind of soft piezoelectric polymer, is adopted for developing transducer. The PVDF devices are flexible and have longer life time than PZT devices under the harmonic environment. The EH researches are mainly focused on the development of energy transfer efficiency either by the mechanical structure of transducer or the improvement of circuit. However, the practicality and stability of the EH devices are important in the practical engineering applications. In this paper, a charge amplifier is introduced in the circuit in order to guarantee the stability of the battery charging under small ambient vibration conditions. The model of the mechanical structure of PVDF and the electric performance of circuit are developed. The experimental results and simulation show that the stability of battery charging is improved and the working time of DC equipment is prolonged.

  8. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won [Division of Medical Device Research, National Institute of Food and Drug Safety Evaluation, Mnistry of Food and Drug Safety (Korea, Republic of)

    2016-12-15

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

  9. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    International Nuclear Information System (INIS)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won

    2016-01-01

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts

  10. A preliminary design of mechanical device on industrial digital radiography equipment design

    International Nuclear Information System (INIS)

    Nur Khasan; Samuel Praptoyo

    2015-01-01

    A preliminary design of mechanical device on industrial digital radiography equipment has been done. this design is intended as a basis for the manufacture of complete facilities for the realization a prototype on industrial digital radiography equipment. the design and construction were carried out by paying attention to the general configuration of the basic design in which its mechanical design has several components with specific dimensions and heavy mass. this design consist of a main frame holder, flat panel detector support and hydraulic hand stacker for mounting the x-ray machine. this mechanical device design will then be fabricated to facilitate and assist work of digital radiographic retrieval. computer application programs sketch-up is used to draw this design and the analysis stress of autodesk inventor to analysis the strength construction design. the results of this design are the configuration drawing, sketch drawings of construction and the safety factor of construction design with a minimum value of 2.39 as well as a maximum value of 15 when to be simulated by the load 500 Kg which is 4 times of total workload. (author)

  11. Methods for medical device and equipment procurement and prioritization within low- and middle-income countries: findings of a systematic literature review.

    Science.gov (United States)

    Diaconu, Karin; Chen, Yen-Fu; Cummins, Carole; Jimenez Moyao, Gabriela; Manaseki-Holland, Semira; Lilford, Richard

    2017-08-18

    Forty to 70 % of medical devices and equipment in low- and middle-income countries are broken, unused or unfit for purpose; this impairs service delivery to patients and results in lost resources. Undiscerning procurement processes are at the heart of this issue. We conducted a systematic review of the literature to August 2013 with no time or language restrictions to identify what product selection or prioritization methods are recommended or used for medical device and equipment procurement planning within low- and middle-income countries. We explore the factors/evidence-base proposed for consideration within such methods and identify prioritization criteria. We included 217 documents (corresponding to 250 texts) in the narrative synthesis. Of these 111 featured in the meta-summary. We identify experience and needs-based methods used to reach procurement decisions. Equipment costs (including maintenance) and health needs are the dominant issues considered. Extracted data suggest that procurement officials should prioritize devices with low- and middle-income country appropriate technical specifications - i.e. devices and equipment that can be used given available human resources, infrastructure and maintenance capacity. Suboptimal device use is directly linked to incomplete costing and inadequate consideration of maintenance services and user training during procurement planning. Accurate estimation of life-cycle costing and careful consideration of device servicing are of crucial importance.

  12. 21 CFR 866.4540 - Immunonephelometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4540 Immunonephelometer equipment. (a) Identification. Immunonephelometer equipment for clinical use...

  13. 21 CFR 866.4520 - Immunofluorometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4520 Immunofluorometer equipment. (a) Identification. Immunofluorometer equipment for clinical use with...

  14. Device for positioning and generation of an element of track model and slice of the MELAS automatic equipment

    International Nuclear Information System (INIS)

    Kryutchenko, E.V.; Fedotov, V.S.

    1979-01-01

    The structure and organization of the device for positioning and generation of element of track model and slice of the MELAS automatic equipment which is developed for measuring films from big bubble chambers, is described. Main features of the device are studied and characteristics are given as well

  15. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  16. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  17. Simulating The Technological Movements Of The Equipment Used For Manufacturing Prosthetic Devices Using 3D Models

    Science.gov (United States)

    Chicea, Anca-Lucia

    2015-09-01

    The paper presents the process of building geometric and kinematic models of a technological equipment used in the process of manufacturing devices. First, the process of building the model for a six axes industrial robot is presented. In the second part of the paper, the process of building the model for a five-axis CNC milling machining center is also shown. Both models can be used for accurate cutting processes simulation of complex parts, such as prosthetic devices.

  18. A novel mechanical design of broken rope protection device for enhancing the safety performances of overhead manned equipment in coal mine

    Directory of Open Access Journals (Sweden)

    Xiaoguang Zhang

    2015-08-01

    Full Text Available A novel mechanical design of the broken rope protection device is proposed to enhance the safety performances of the overhead manned equipment. According to the operating characteristics and functional requirements of the overhead manned equipment, a three-dimensional mechanical model of the broken rope protection device was redesigned. Based on the known parameters of the mechanical model, the stress and strength of the main components are readjusted using the statics characteristics of finite element analysis. To ensure the reliability of the control system of the broken rope protection device, the process of people’s falling, the response performance of the tension sensor, and the signal extraction of the broken rope are analyzed under different loading and unloading speeds. The working principle of the broken rope protection device is expounded in detail. The experimental results showed that better effect is obtained by the new broken rope protection device, which is characterized by good durability, low investment, and high reliability.

  19. On the preparation of fire-wood splitting machines equipped with feeder devices

    International Nuclear Information System (INIS)

    Jaeaeskelaeinen, M.

    1995-01-01

    As part of the Bionergy research programme, the TTS Institute's Department of Forestry conducted a study on firewood splitting machines manufactured by Bilke Oy and Peurala Oy. The said machines are the first of their kind in Finland to be equipped with a feeder device. The Bilke unit is fed by a conveyor belt arrangement while the Peurala unit is equipped with a feeder roll. In addition, both machine types are equipped with a conveyor belt discharging device (e.g. for discharging split wood directly into a trailer). The Bilke unit can also be operated on extraction racks in the woods as the stems due to be split are fed into it from the side and the conveyor discharges the split wood rearwards into the trailer. The trailer can be hooked onto the splitting unit's draw-hook. At the landing, the Bilke unit was used to split a total of 14.2 m 3 and the Peurala unit 8.0 m 3 of approx. 3-metrelong stems averaging 9 cm in diameter. In addition to this, the Bilke unit was used to split ca. 17 m 3 of 3.5 metre-long stems with on average diameter of ca. 6 cm; the stems were in bunches alongside the extraction racks. The person operating the machines for the purposes of this study was a 27-year- old forest worker. The mean productivity achieved at the landing when using the Bilke unit was 7.7 m 3 while that of the Peurala unit was 5.8 m 3 per effective hour. When operated in the woods, the productivity achieved with the Bilke unit (excluding felling-cross cutting-delimbing-bunching and forest haulage work) was 2.8 m 3 /h. When applying a productivity of 1.7 m 3 for felling-cross cutting- delimbing-bunching work and 5.5. m 3 for forest haulage, the entire harvesting chain's productivity was 0.9 m 3 per effective hour

  20. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  1. Free-world microelectronic manufacturing equipment

    Science.gov (United States)

    Kilby, J. S.; Arnold, W. H.; Booth, W. T.; Cunningham, J. A.; Hutcheson, J. D.; Owen, R. W.; Runyan, W. R.; McKenney, Barbara L.; McGrain, Moira; Taub, Renee G.

    1988-12-01

    Equipment is examined and evaluated for the manufacture of microelectronic integrated circuit devices and sources for that equipment within the Free World. Equipment suitable for the following are examined: single-crystal silicon slice manufacturing and processing; required lithographic processes; wafer processing; device packaging; and test of digital integrated circuits. Availability of the equipment is also discussed, now and in the near future. Very adequate equipment for most stages of the integrated circuit manufacturing process is available from several sources, in different countries, although the best and most widely used versions of most manufacturing equipment are made in the United States or Japan. There is also an active market in used equipment, suitable for manufacture of capable integrated circuits with performance somewhat short of the present state of the art.

  2. 21 CFR 866.4830 - Rocket immunoelectro-phoresis equipment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents... equipment for clinical use is a device used to perform a specific test on proteins by using a procedure...

  3. Operation monitor for plant equipment

    International Nuclear Information System (INIS)

    Kondo, Tetsufumi; Kanemoto, Shigeru.

    1991-01-01

    In a nuclear power plant, states of each of equipment in the plant are monitored accurately even under such a operation condition that the power is changed. That is, the fundamental idea is based on a model comparison method. A deviation between an output signal upon normal plant state obtained in a forecasting model device and that of the objective equipment in the plant are compared with a predetermined value. The result of the comparison is inputted to an alarm device to alarm the abnormality of the states of the equipment to an operator. The device of the present invention thus constituted can monitor the abnormality of the operation of equipment accurately even under such a condition that a power level fluctuates. As a result, it can remarkably contribute to mitigate operator's monitoring operation under the condition such as during load following operation. (I.S.)

  4. 14 CFR 101.35 - Equipment and marking requirements.

    Science.gov (United States)

    2010-01-01

    ... unmanned free balloon unless— (1) It is equipped with at least two payload cut-down systems or devices that operate independently of each other; (2) At least two methods, systems, devices, or combinations thereof... envelope; and (3) The balloon envelope is equipped with a radar reflective device(s) or material that will...

  5. 21 CFR 870.4200 - Cardiopulmonary bypass accessory equipment.

    Science.gov (United States)

    2010-04-01

    ... Cardiopulmonary bypass accessory equipment. (a) Identification. Cardiopulmonary bypass accessory equipment is a... mounting bracket or system-priming equipment. (b) Classification. (1) Class I. The device is classified as class I if it does not involve an electrical connection to the patient. The device is exempt from the...

  6. 21 CFR 866.4500 - Immunoelectrophoresis equipment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents... clinical use with its electrical power supply is a device used for separating protein molecules...

  7. ACED devices and SECAF supports for the control of structure, pipe network and equipment behaviour at seismic movements in order to enhance the safety margin

    International Nuclear Information System (INIS)

    Serban, Viorel; Prisecaru, I.; Cretu, D.; Moldoveanu, T.

    2002-01-01

    In order to enhance the safety margin of structure, pipe networks and equipment associated to the existing NPPs, the classic consolidation solutions are very expensive and many times, impossible to be implemented. Structures, pipe networks, systems and equipment have geometries imposed by the basic construction requirements, operating and safety requirements and their modifications is not always possible. In order to enhance the strength capacity of (new or old) structures, systems and equipment mechanical devices with controlled elasticity and damping (ACED) have been designed, constructed and experimented. These devices are capable to support very large static loads over which dynamic loads (shock, vibration and seismic movements) overlap (which are damped). To increase the strength capacity of (new or existing) pipe networks and equipment connecting with pipes, SECAF supports that allow displacements from thermal expansions with low reaction force have been designed, constructed and experimented. SECAF supports are capable elastically to take permanent loads over which shocks, vibrations and seismic movements (which are damp) overlap. ACED devices and SECAF supports can be used to rehabilitate the existing NPPs with law financial costs and an increase of their strength capacity up to 100% under seismic movements, shocks and vibrations. ACED devices and SECAF supports do not require maintenance, are not affected by presence of a radiation field and their estimated service-life is similar to the NPPs

  8. Periodic orbits of solar sail equipped with reflectance control device in Earth-Moon system

    Science.gov (United States)

    Yuan, Jianping; Gao, Chen; Zhang, Junhua

    2018-02-01

    In this paper, families of Lyapunov and halo orbits are presented with a solar sail equipped with a reflectance control device in the Earth-Moon system. System dynamical model is established considering solar sail acceleration, and four solar sail steering laws and two initial Sun-sail configurations are introduced. The initial natural periodic orbits with suitable periods are firstly identified. Subsequently, families of solar sail Lyapunov and halo orbits around the L1 and L2 points are designed with fixed solar sail characteristic acceleration and varying reflectivity rate and pitching angle by the combination of the modified differential correction method and continuation approach. The linear stabilities of solar sail periodic orbits are investigated, and a nonlinear sliding model controller is designed for station keeping. In addition, orbit transfer between the same family of solar sail orbits is investigated preliminarily to showcase reflectance control device solar sail maneuver capability.

  9. Automatic monitoring of vibration welding equipment

    Science.gov (United States)

    Spicer, John Patrick; Chakraborty, Debejyo; Wincek, Michael Anthony; Wang, Hui; Abell, Jeffrey A; Bracey, Jennifer; Cai, Wayne W

    2014-10-14

    A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

  10. Electronic equipment for spectrometric data processing

    International Nuclear Information System (INIS)

    Antonov, L.J.; Trenev, A.M.; Todorova, E.I.; Dimitrov, V.D.

    1978-01-01

    Electronic equipment carrying out logical operations and a full set of the arithmetic operations was developed for spectrometric data processing. The flowsheet of the computing part of the device, made on the basis of a specialized integral circuit, is given. The device includes input registers, multiplexor, matrix commutator, arithmetic unit and indication unit. The equipment is rated to carry out calculations according to comparatively complex formulae in several seconds

  11. 46 CFR 184.220 - Cooking equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Cooking equipment. 184.220 Section 184.220 Shipping...) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Cooking and Heating § 184.220 Cooking equipment. (a) Doors on a cooking appliance must be provided with hinges and locking devices to prevent...

  12. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  13. Waste heat recovering device for reactors

    International Nuclear Information System (INIS)

    Sonoda, Masanobu; Shiraishi, Tadashi; Mizuno, Hiroyuki; Sekine, Yasuhiro.

    1982-01-01

    Purpose: To enable utilization of auxiliary-equipment-cooling water from a non-regenerative heat exchanger as a heat source, as well as prevent radioactive contamination. Constitution: A water warming device for recovering the heat of auxiliary equipment cooling water from a non-regenerative heat exchanger is disposed at the succeeding stage of the heat exchanger. Heat exchange is performed in the water warming device between the auxiliary equipment cooling water and a heat source water set to a higher pressure and recycled through the water warming device. The heat recovered from the auxiliary equipment cooling water is utilized in the heat source water for operating relevant equipments. (Aizawa, K.)

  14. 47 CFR 15.305 - Equipment authorization requirement.

    Science.gov (United States)

    2010-10-01

    ... Section 15.305 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unlicensed Personal Communications Service Devices § 15.305 Equipment authorization requirement. PCS devices... 2 of this chapter before marketing. The application for certification must contain sufficient...

  15. Equipment abnormality monitoring method and device therefor

    International Nuclear Information System (INIS)

    Yamada, Izumi; Asakura, Yamato; Uemura, Hiroshi; Uchida, Shunsuke; Oyamada, Osamu; Oyobe, Koji.

    1994-01-01

    In the present invention, it is judged whether the operation state of equipments used in a plant are normal or not by using learning performances. That is, a plurality of monitoring parameters are measured for an equipment. Previously determined monitoring parameters are extracted. A leaning mode or a monitoring mode is selected. In the leaning mode, based on the values of previously determined monitoring parameters, values of other monitoring parameters during normal states are learned. In the monitoring mode, based on the values of the previously determined monitoring parameters, typical values of other leaned monitoring parameters are outputted. The typical values of other normal monitoring parameters after learning and the values of other parameters at the present time are compared. If the values of the other parameters at the present time are out of normal range, it is judged as abnormal, and the result is alarmed and displayed. (I.S.)

  16. In-use NOx emissions from model year 2010 and 2011 heavy-duty diesel engines equipped with aftertreatment devices.

    Science.gov (United States)

    Misra, Chandan; Collins, John F; Herner, Jorn D; Sax, Todd; Krishnamurthy, Mohan; Sobieralski, Wayne; Burntizki, Mark; Chernich, Don

    2013-07-16

    The California Air Resources Board (ARB) undertook this study to characterize the in-use emissions of model year (MY) 2010 or newer diesel engines. Emissions from four trucks: one equipped with an exhaust gas recirculation (EGR) and three equipped with EGR and a selective catalytic reduction (SCR) device were measured on two different routes with three different payloads using a portable emissions measurement system (PEMS) in the Sacramento area. Results indicated that brake-specific NOx emissions for the truck equipped only with an EGR were independent of the driving conditions. Results also showed that for typical highway driving conditions, the SCR technology is proving to be effective in controlling NOx emissions. However, under operations where the SCR's do not reach minimum operating temperature, like cold starts and some low load/slow speed driving conditions, NOx emissions are still elevated. The study indicated that strategies used to maintain exhaust temperature above a certain threshold, which are used in some of the newer SCRs, have the potential to control NOx emissions during certain low-load/slow speed driving conditions.

  17. 46 CFR 111.51-3 - Protection of vital equipment.

    Science.gov (United States)

    2010-10-01

    ...-GENERAL REQUIREMENTS Coordination of Overcurrent Protective Devices § 111.51-3 Protection of vital equipment. (a) The coordination of overcurrent protective devices must be demonstrated for all potential... 46 Shipping 4 2010-10-01 2010-10-01 false Protection of vital equipment. 111.51-3 Section 111.51-3...

  18. [Equipment design for magnetic therapy and "Polus" devices].

    Science.gov (United States)

    Viktorov, V A; Malkov, Iu V

    1994-01-01

    Low-frequency magnetotherapy is among the most original therapeutical techniques since it is effective in treating most diseases and has practically no contraindications. Due to atraumaticity of a low-frequency electromagnetic field, the application of magnetotherapy is indicated in geriatric care, in particular. The VNIIMP-VITA Joint-Stock Company has developed a family of the Polyus system equipment for magnetotherapy, whereby all the well-known therapeutical procedures of low-frequency magnetotherapy can be performed. The magnetotherapeutic room equipped with Polyus-2D, Polyus-3, and Polyus-4 ensures a complete set of magneto-therapeutical exposure. The rooms are supplied by the VNIIMP-VITA Joint-Stock Company.

  19. Plant equipment integrity monitoring and diagnosing method and device therefor, plant equipment maintenance and inspection time determining method and device therefor, as well as nuclear power plant

    International Nuclear Information System (INIS)

    Kato, Takahiko; Ando, Masashi; Osumi, Katsumi; Horiuchi, Tetsuo; Asakura, Yamato; Akamine, Kazuhiko.

    1995-01-01

    The present invention can accurately forecast a time for occurrence of troubles of plant equipments in contact with recycling water, to conduct its maintenance and inspection before occurrence of the troubles. Namely, change of water quality in plant equipments caused by corrosion of recycling water occurred in constitutional parts of the plant equipments is measured. The time upon occurrence of the troubles of the plant equipments to corrosion of the recycling water is forecast based on the measured value. A time till the occurrence of the change of water quality after starting the use of the plant equipments is calculated based on the measured value. The calculated time is compared with a correlation between the time of occurrence of the troubles after starting the use of the plant equipments and the time of occurrence of change of the water quality, to forecast the time of occurrence of the troubles. Preferably, electroconductivity and pH of recycling water in the inside or at the exit of the plant equipments are measured as an object for the measurement of change of water quality. (I.S.)

  20. Prevention of Medical Device-Related Pressure Injuries Associated With Respiratory Equipment Use in a Critical Care Unit: A Quality Improvement Project.

    Science.gov (United States)

    Padula, Cynthia A; Paradis, Heidi; Goodwin, Robert; Lynch, Judith; Hegerich-Bartula, Deborah

    Medical devices have been identified as an extrinsic risk factor for development of pressure injuries, with as many as 30% to 70% of medical device-related pressure injuries resulting from respiratory equipment. This article describes a quality improvement project undertaken to reduce the occurrence of respiratory device-related pressure injuries in a critically care unit. Multiple actions were implemented to achieve this goal. Respiratory therapists were trained to document occurrences on a daily basis, and apparent cause analyses were conducted on each occurrence. An interdisciplinary team conducted biweekly rounds on patients with respiratory devices and consulted other professionals as indicated. Nurses and respiratory therapists attended an evidence-based, collaborative, educational offering and completed a measure of team functioning before the program and at the end of the study period. The occurrence rates of respiratory device-related pressure injuries were reduced over the project period, and these changes were sustained over the subsequent 12 months.

  1. Developing equipment for AGR remote visual inspection

    International Nuclear Information System (INIS)

    James, P.W.; Walton, P.J.

    1985-01-01

    The Remote Inspection Group is part of the CEGB's Generation Development and Construction Division, and has responsibility for the design, development, procurement, testing and setting to work of the equipment provided to carry out routine remote visual inspections of its AGRs. This equipment includes both the viewing devices and the necessary placement equipment. (author)

  2. Design and fabrication of equipment and devices for a Radiotherapy department; Diseno y fabricacion de equipos y aditamentos para un departamento de Radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Picon, C.L.; Zaharia B, M. [Departamento de Radioterapia. Instituto de Enfermedades Neoplasicas, Av. Angamos Este 2520, Lima (Peru)

    1998-12-31

    The objective of this work is to present the possibility to design and construct utilizing local technology, a series of equipment and devices necessaries for a routine in a Radiotherapy Department with typical budget in the Latin-American hospitals. (Author)

  3. Sodium cleaning device for nuclear reactor equipments

    International Nuclear Information System (INIS)

    Fujisawa, Morio.

    1985-01-01

    Purpose: To enable sodium cleaning over the entire length of large size equipments such as control rod drives and primary coolant recycling pumps for use in FBR type reactors. Constitution: A plurality of warm water supply nozzles each having a valve are connected at varying height on the side of a cleaning tank, to which an exhaust line is connected. These nozzles are connected with an exhaust port at the bottom of the tank to constitute a pipeway for cleaning warm water recycling line including a water feed pump and a feedwater heater. The water level in the tank is changed stepwise by successively selecting the warm water feed nozzles. Further, the warm water in the tank is recyclically fed through the nozzles selected at each step of the water level through the recycle line while warming. On the other hand, the pressure inside the tank is reduced through the exhaust line, whereby the warm water in the tank is boiled at low temperature to clean-up sodium on the equipments to be cleaned over the entire length. (Horiuchi, T.)

  4. Market Potential for Residential Biomass Heating Equipment: Stochastic and Econometric Assessments

    OpenAIRE

    Adee Athiyaman

    2015-01-01

    This paper provides estimates of market potential for biomass-residential-heating equipment in the US: that is, the greatest amount of biomass-residential-heating equipment that can be sold by the industry. The author's analysis is limited to biomass equipment used most to heat the housing unit. Assuming that households equipped with 10+ year old primary heating devices will replace rather than repair the devices he predicts that approximately 1.4 million units of residential home heating equ...

  5. Interventional suite and equipment management: cradle to grave

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, Keith J. [Harvard Medical School, Radiology Physics and Engineering, Children' s Hospital Boston, Boston, MA (United States)

    2006-09-15

    The acquisition process for interventional equipment and the care that this equipment receives constitute a comprehensive quality improvement program. This program strives to (a) achieve the production of good image quality that meets clinical needs, (b) reduce radiation doses to the patient and personnel to their lowest possible levels, and (c) provide overall good patient care at reduced cost. Interventional imaging equipment is only as effective and efficient as its supporting facility. The acquisition process of interventional equipment and the development of its environment demand a clinical project leader who can effectively coordinate the efforts of the many professionals who must communicate and work effectively on this type of project. The clinical project leader needs to understand (a) clinical needs of the end users, (b) how to justify the cost of the project, (c) the technical needs of the imaging and all associated equipment, (d) building and construction limitations, (e) how to effectively read construction drawings, and (f) how to negotiate and contract the imaging equipment from the appropriate vendor. After the initial commissioning of the equipment, it must not be forgotten. The capabilities designed into the imaging device can be properly utilized only by well-trained operators and staff who were initially properly trained and receive ongoing training concerning the latest clinical techniques throughout the equipment's lifetime. A comprehensive, ongoing maintenance and repair program is paramount to reducing costly downtime of the imaging device. A planned periodic maintenance program can identify and eliminate problems with the imaging device before these problems negatively impact patient care. (orig.)

  6. Interventional suite and equipment management: cradle to grave

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2006-01-01

    The acquisition process for interventional equipment and the care that this equipment receives constitute a comprehensive quality improvement program. This program strives to (a) achieve the production of good image quality that meets clinical needs, (b) reduce radiation doses to the patient and personnel to their lowest possible levels, and (c) provide overall good patient care at reduced cost. Interventional imaging equipment is only as effective and efficient as its supporting facility. The acquisition process of interventional equipment and the development of its environment demand a clinical project leader who can effectively coordinate the efforts of the many professionals who must communicate and work effectively on this type of project. The clinical project leader needs to understand (a) clinical needs of the end users, (b) how to justify the cost of the project, (c) the technical needs of the imaging and all associated equipment, (d) building and construction limitations, (e) how to effectively read construction drawings, and (f) how to negotiate and contract the imaging equipment from the appropriate vendor. After the initial commissioning of the equipment, it must not be forgotten. The capabilities designed into the imaging device can be properly utilized only by well-trained operators and staff who were initially properly trained and receive ongoing training concerning the latest clinical techniques throughout the equipment's lifetime. A comprehensive, ongoing maintenance and repair program is paramount to reducing costly downtime of the imaging device. A planned periodic maintenance program can identify and eliminate problems with the imaging device before these problems negatively impact patient care. (orig.)

  7. Electrical apparatus lockout device

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, R.

    1999-10-12

    A simple lockout device for electrical equipment equipped with recessed power blades is described. The device comprises a face-plate (12) having a threaded member (14) attached thereto and apertures suitable for accommodating the power blades of a piece of electrical equipment, an elastomeric nose (16) abutting the face-plate having a hole for passage of the threaded member therethrough and power blade apertures in registration with those of the face-plate, a block (20) having a recess (34) in its forward face for receiving at least a portion of the hose, a hole therein for receiving the threaded member and an integral extension (26) extending from its rear face. A thumb screw (22) suitable for turning with the hands and having internal threads suitable for engaging the threaded member attached to the face-plate is inserted into a passage in the integral extension to engage the threaded member in such a fashion that when the device is inserted over the recessed power blades of a piece of electrical equipment and the thumb screw (22) tightened, the elastomeric nose (16) is compressed between the face-plate (12) and the block (20) forcing it to expand laterally thereby securing the device in the recess and precluding the accidental or intentional energization of the piece of equipment by attachment of a power cord to the recessed power blades. Means are provided in the interval extension and the thumb screw for the attachment of a locking device (46) which will satisfy OSHA standards.

  8. Electrical apparatus lockout device

    International Nuclear Information System (INIS)

    Gonzales, R.

    1999-01-01

    A simple lockout device for electrical equipment equipped with recessed power blades is described. The device comprises a face-plate (12) having a threaded member (14) attached thereto and apertures suitable for accommodating the power blades of a piece of electrical equipment, an elastomeric nose (16) abutting the face-plate having a hole for passage of the threaded member therethrough and power blade apertures in registration with those of the face-plate, a block (20) having a recess (34) in its forward face for receiving at least a portion of the hose, a hole therein for receiving the threaded member and an integral extension (26) extending from its rear face. A thumb screw (22) suitable for turning with the hands and having internal threads suitable for engaging the threaded member attached to the face-plate is inserted into a passage in the integral extension to engage the threaded member in such a fashion that when the device is inserted over the recessed power blades of a piece of electrical equipment and the thumb screw (22) tightened, the elastomeric nose (16) is compressed between the face-plate (12) and the block (20) forcing it to expand laterally thereby securing the device in the recess and precluding the accidental or intentional energization of the piece of equipment by attachment of a power cord to the recessed power blades. Means are provided in the interval extension and the thumb screw for the attachment of a locking device (46) which will satisfy OSHA standards

  9. Low level photoneutron detection equipment

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Yuqin; Li Yuansui

    1991-01-01

    A low level photoneutron detection equipment has been developed. The photoneutrons produced by interaction of 226 Ra gamma quanta and deutron (D) target are detected with n-n discrimination detector made up of 3 He proportional counter array. The D-content information in the target can be obtained from the measured photoneutron counts. The equipment developed is mainly used for nondestructive D-content measurement of D-devices

  10. Ionizing secondary radiation generated by analog radiological and digital coronary cine angiographic equipment. Influence of external protection devices

    International Nuclear Information System (INIS)

    Ramirez N, Alfredo; Farias Ch, Eric; Silva J, Ana Maria; Leyton L, Fernando; Oyarzun C, Carlos; Ugalde P, Hector; Dussaillant, Gaston; Cumsille G, Angel

    2000-01-01

    Exposure to ionizing radiation is a know hazard of radiological procedures. Aim: to compare the emission of secondary ionizing radiation from two coronary angiographic equipments, one with digital and the other with analog image generation. To evaluate the effectiveness of external radiological protection devices. Material and methods: environmental and fluoroscopy generated radiation in the cephalic region of the patient was measured during diagnostic coronary angiographies. Ionizing radiation generated in anterior left oblique protection (ALO) and anterior right oblique protection (ARO) were measured with and without leaded protections. In 19 patients (group 1), a digital equipment was used and in 21 (group 2), an analog equipment. Results: header radiation for group 1 and 2 was 1194±337 and 364±222 μGray/h respectively (p≤0.001). During fluoroscopy and with leaded protection generated radiation for groups 1 and 2 was 612±947 and 70±61μGray/h respectively (p≤0.001). For ALO projection, generated for groups 1 and 2 was 105±47 and 71±192 μGray/h respectively (p≤0.001). During filming the radiation for ALO projection for groups 1 and 2 was 7252±9569 and 1671±2038 μGray/h respectively (p=0.03). Out of the protection zone, registered radiation during fluoroscopy for groups 1 and 2 was 2800±1741 and 1318±954 μGray/h respectively (p≤0.001); during filming, the figures were 15500±5840 and 18961±10599 μGray/h respectively (NS). Conclusions: digital radiological equipment has a lower level of ionizing radiation emission than the analog equipment

  11. The Difficult Airway Society 'ADEPT' guidance on selecting airway devices: the basis of a strategy for equipment evaluation.

    Science.gov (United States)

    Pandit, J J; Popat, M T; Cook, T M; Wilkes, A R; Groom, P; Cooke, H; Kapila, A; O'Sullivan, E

    2011-08-01

    Faced with the concern that an increasing number of airway management devices were being introduced into clinical practice with little or no prior evidence of their clinical efficacy or safety, the Difficult Airway Society formed a working party (Airway Device Evaluation Project Team) to establish a process by which the airway management community within the profession could itself lead a process of formal device/equipment evaluation. Although there are several national and international regulations governing which products can come on to the market and be legitimately sold, there has hitherto been no formal professional guidance relating to how products should be selected (i.e. purchased). The Airway Device Evaluation Project Team's first task was to formulate such advice, emphasising evidence-based principles. Team discussions led to a definition of the minimum level of evidence needed to make a pragmatic decision about the purchase or selection of an airway device. The Team concluded that this definition should form the basis of a professional standard, guiding those with responsibility for selecting airway devices. We describe how widespread adoption of this professional standard can act as a driver to create an infrastructure in which the required evidence can be obtained. Essential elements are that: (i) the Difficult Airway Society facilitates a coherent national network of research-active units; and (ii) individual anaesthetists in hospital trusts play a more active role in local purchasing decisions, applying the relevant evidence and communicating their purchasing decisions to the Difficult Airway Society. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  12. 49 CFR 220.38 - Communication equipment failure.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Communication equipment failure. 220.38 Section 220.38 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... § 220.38 Communication equipment failure. (a) Any radio or wireless communication device found not to be...

  13. EAS Equipment Authorization Grantee Registrations

    Data.gov (United States)

    Federal Communications Commission — EAS (Equipment Authorization System). Radio Frequency (RF) devices are required to be properly authorized under 47 CFR Part 2 prior to being marketed or imported...

  14. 30 CFR 56.9302 - Protection against moving or runaway railroad equipment.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection against moving or runaway railroad..., and Loading and Dumping Sites § 56.9302 Protection against moving or runaway railroad equipment. Stopblocks, derail devices, or other devices that protect against moving or runaway rail equipment shall be...

  15. 30 CFR 57.9302 - Protection against moving or runaway railroad equipment.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection against moving or runaway railroad..., Railroads, and Loading and Dumping Sites § 57.9302 Protection against moving or runaway railroad equipment. Stopblocks, derail devices, or other devices that protect against moving or runaway rail equipment shall be...

  16. Hoisting appliances and fuel handling equipment at nuclear facilities

    International Nuclear Information System (INIS)

    1987-01-01

    The guide is followed by the Finnish Centre for Radiation and Nuclear Safety (STUK) in regulating hoisting and handling equipment Class 3 at nuclear facilities. The guide is applied e.g. to the following equipment: reactor building overhead cranes, hoisting appliances at nuclear fuel storages, fuel handling machines, other hoisting appliances, which because of nuclear safety aspects are classified in Safety Class 3, and load-bearing devices connected with the above equipment, such as replaceable hoisting tools and auxiliary lifting devices. The regulating of hoisting and handling equipment comprises the following stages: handling of preliminary and final safety analysis reports, inspection of the construction plan, supervision of fabrication and construction inspection, and supervision of initial start-up and commissioning inspection

  17. Current state of commercial radiation detection equipment for homeland security applications

    International Nuclear Information System (INIS)

    Klann, R.T.; Shergur, J.; Mattesich, G.

    2009-01-01

    With the creation of the U.S. Department of Homeland Security (DHS) came the increased concern that terrorist groups would attempt to manufacture and use an improvised nuclear device or radiological dispersal device. As such, a primary mission of DHS is to protect the public against the use of these devices and to assist state and local responders in finding, locating, and identifying these types of devices and materials used to manufacture these devices. This assistance from DHS to state and local responders comes in the form of grant money to procure radiation detection equipment. In addition to this grant program, DHS has supported the development of American National Standards Institute standards for radiation detection equipment and has conducted testing of commercially available instruments. This paper identifies the types and kinds of commercially available equipment that can be used to detect and identify radiological material - for use in traditional search applications as well as primary and secondary screening of personnel, vehicles, and cargo containers. In doing so, key considerations for the conduct of operations are described as well as critical features of the instruments for specific applications. The current state of commercial instruments is described for different categories of detection equipment including personal radiation detectors, radioisotope identifiers, man-portable detection equipment, and radiation portal monitors. In addition, emerging technologies are also discussed, such as spectroscopic detectors and advanced spectroscopic portal monitors

  18. 46 CFR 169.685 - Electric heating and cooking equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Electric heating and cooking equipment. 169.685 Section... More on Vessels of Less Than 100 Gross Tons § 169.685 Electric heating and cooking equipment. (a) Each...) All electric cooking equipment, attachments, and devices, must be of rugged construction and so...

  19. [Rehabilitation of women suffering chronic cystitis in the postmenopausal period with the use of an AMUS-01 - Intramag apparatus equipped with a Rektomassazher device].

    Science.gov (United States)

    Azizov, A P; Azizova, P A; Beliaev, A A; Konova, A N; Raĭgorodskiĭ, Iu M

    2011-01-01

    The objective of the present study was to develop a rationale for the local treatment of chronic recurring cystitis in the postmenopausel period. To this effect, 76 patients at the mean age of 66.4 years with this pathology were examined and the data obtained were compared with observations of control postmenopausel women receiving traditional local substitution hormonal therapy. In the patients of the study group, this treatment was supplemented by intravaginal vibro-magnetotherapy and the conventional antibacterial therapy was replaced by local electrophoresis. All local physiotherapeutic procedures were performed with the use of a AMUS-01 - Intramag apparatus equipped with a Rektomassazher device an AMUS-01 - Intramag apparatus equipped with a Rektomassazher device. The immunological analysis of vaginal secretion coupled to bacterial and clinical investigations have demonstrated the advantages of the combined local treatment including physiotherapy. The integral efficacy index was by a factor of 1.8 higher than in the control group.

  20. Protective device for battery to protect against heavy discharge

    Energy Technology Data Exchange (ETDEWEB)

    1979-02-08

    The protective device according to the invention switches the equipment being supplied from the battery at a pre-determined discharge voltage by means of a switching device controlled by monitoring equipment. A semi-conductor element is used as the switching device. The current taken from the battery flows through the semi-conductor element to the equipment and to the monitoring device. When the discharge voltage is reached the semi-conductor element blocks. The semi-conductor switch can consist of transistors. The invention is explained by means of drawings and examples.

  1. Analysis of the steel braced frames equipped with ADAS devices under the far field records

    Directory of Open Access Journals (Sweden)

    Mahmoud Bayat

    Full Text Available The usefulness of supplementary energy dissipation devices is now quite well-known in earthquake structural engineering for reducing the earthquake-induced response of structural systems. The seismic behavior of structures with supplemental ADAS devices is concerned in this study. In this paper, the ratio of the hysteretic energy to input energy is compared in different structural systems. The main purpose of this paper is to evaluate the behavior of structures equipped with yielding dampers (ADAS, located in far fields based on energy concepts. In order to optimize their seismic behavior, the codes and solutions are also presented. Three cases including five, ten and fifteen-story three-bay Concentric Braced Frames (CBF with and without ADAS were selected. The PERFORM 3D.V4 software along with three earthquake records (Northridge, Imperial Valley and Tabas is used for nonlinear time history analysis and the conclusions are drawn upon energy criterion. The effect of PGA variation and height of the frames are also considered in the study. Finally, to increase the energy damping ability and reduce the destructive effects in structures on an earthquake event, so that a great amount of induced energy is damped and destruction of the structure is prevented as much as possible by using ADAS dampers.

  2. Data Network Equipment Energy Use and Savings Potential in Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lanzisera, Steven; Nordman, Bruce; Brown, Richard E.

    2010-06-09

    Network connectivity has become nearly ubiquitous, and the energy use of the equipment required for this connectivity is growing. Network equipment consists of devices that primarily switch and route Internet Protocol (IP) packets from a source to a destination, and this category specifically excludes edge devices like PCs, servers and other sources and sinks of IP traffic. This paper presents the results of a study of network equipment energy use and includes case studies of networks in a campus, a medium commercial building, and a typical home. The total energy use of network equipment is the product of the stock of equipment in use, the power of each device, and their usage patterns. This information was gathered from market research reports, broadband market penetration studies, field metering, and interviews with network administrators and service providers. We estimate that network equipment in the USA used 18 TWh, or about 1percent of building electricity, in 2008 and that consumption is expected to grow at roughly 6percent per year to 23 TWh in 2012; world usage in 2008 was 51 TWh. This study shows that office building network switches and residential equipment are the two largest categories of energy use consuming 40percent and 30percent of the total respectively. We estimate potential energy savings for different scenarios using forecasts of equipment stock and energy use, and savings estimates range from 20percent to 50percent based on full market penetration of efficient technologies.

  3. 21 CFR 864.3010 - Tissue processing equipment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tissue processing equipment. 864.3010 Section 864.3010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3010...

  4. Department of Thermonuclear Research annual report 1993

    International Nuclear Information System (INIS)

    Sadowski, M.; Pawlowicz, W.

    1994-01-01

    Department of Thermonuclear Research Annual Report 1993 presents a short review of theoretical, experimental and technological studies performed within the framework of the research program - Plasma Physics. Theoretical studies of a tokamak edge plasma, inner shell ionization by positrons, heat transfer in thin foils, and numerical simulation of HV pulse generators, are summarized. Experimental studies of X-rays and charged particles (including fusion protons) emitted from Plasma-Focus facilities, as well as measurements of plasma-ion streams generated by IONOTRON devices, are described shortly. Also presented are technological studies on data acquisition systems and material engineering, in particular the modification of solid surfaces with the plasma-ion streams. (author)

  5. Department of Thermonuclear Research. Annual report 1988

    International Nuclear Information System (INIS)

    Sadowski, M.

    1989-01-01

    Department of Thermonuclear Research annual report 1988 presents a short review of theoretical, experimental and technological studies performed within a framework of two research programs: diagnostics of high-temperature plasma and nuclear technology. We describe theoretical investigations on the modelling of Tokamak edge plasmas, ion motions, atomic collisions, high-voltage electrode systems and plasma-focus (PF) facilities. The experimental studies on plasma-ion streams, high-current discharges of the PF-type, and on the interaction of ion beams with gaseous targets, are shortly summarized. Also presented are technological studies on electronic and high-voltage systems, as well as applications of the IONOTRON type plasma devices. (author)

  6. Department of Thermonuclear Research annual report 1993

    Energy Technology Data Exchange (ETDEWEB)

    Sadowski, M; Pawlowicz, W [eds.; Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

    1994-12-31

    Department of Thermonuclear Research Annual Report 1993 presents a short review of theoretical, experimental and technological studies performed within the framework of the research program - Plasma Physics. Theoretical studies of a tokamak edge plasma, inner shell ionization by positrons, heat transfer in thin foils, and numerical simulation of HV pulse generators, are summarized. Experimental studies of X-rays and charged particles (including fusion protons) emitted from Plasma-Focus facilities, as well as measurements of plasma-ion streams generated by IONOTRON devices, are described shortly. Also presented are technological studies on data acquisition systems and material engineering, in particular the modification of solid surfaces with the plasma-ion streams. (author).

  7. [Prevention of medical device-related adverse events in hospitals: Specifying the recommendations of the German Coalition for Patient Safety (APS) for users and operators of anaesthesia equipment].

    Science.gov (United States)

    Bohnet-Joschko, Sabine; Zippel, Claus; Siebert, Hartmut

    2015-01-01

    The use and organisation of medical technology has an important role to play for patient and user safety in anaesthesia. Specification of the recommendations of the German Coalition for Patient Safety (APS) for users and operators of anaesthesia equipment, explore opportunities and challenges for the safe use and organisation of anaesthesia devices. We conducted a literature search in Medline/PubMed for studies dealing with the APS recommendations for the prevention of medical device-related risks in the context of anaesthesia. In addition, we performed an internet search for reports and recommendations focusing on the use and organisation of medical devices in anaesthesia. Identified studies were grouped and assigned to the recommendations. The division into users and operators was maintained. Instruction and training in anaesthesia machines is sometimes of minor importance. Failure to perform functional testing seems to be a common cause of critical incidents in anaesthesia. There is a potential for reporting to the federal authority. Starting points for the safe operation of anaesthetic devices can be identified, in particular, at the interface of staff, organisation, and (anaesthesia) technology. The APS recommendations provide valuable information on promoting the safe use of medical devices and organisation in anaesthesia. The focus will be on risks relating to the application as well as on principles and materials for the safe operation of anaesthesia equipment. Copyright © 2015. Published by Elsevier GmbH.

  8. Proceedings of FED remote maintenance equipment workshop

    International Nuclear Information System (INIS)

    Sager, P.; Garin, J.; Hager, E.R.; Spampinato, P.T.; Tobias, D.; Young, N.

    1981-11-01

    A workshop was convened in two sessions in January and March 1981, on the remote maintenance equipment for the Fusion Engineering Device (FED). The objectives of the first session were to familiarize the participants with the status of the design of the FED and to develop a remote maintenance equipment list for the FED. The objective of the second session was to have the participants present design concepts for the equipment which had been identified in the first session. The equipment list was developed for general purpose and special purpose equipment. The general purpose equipment was categorized as manipulators and other, while the special purpose equipment was subdivided according to the reactor subsystem it serviced: electrical, magnetic, and nuclear. Both mobile and fixed base manipulators were identified. Handling machines were identified as the major requirement for special purpose equipment

  9. Plant operation monitoring method and device therefor

    International Nuclear Information System (INIS)

    Ando, Tsugio; Matsuki, Tsutomu.

    1997-01-01

    The present invention provides a method of and a device for monitoring the operation of a nuclear power plant during operation, which improves the safety and reliability of operation without increasing an operator's burden. Namely, a chief in charge orally instruct an operation to an operator upon the operation of a plant constituent equipment. The operator points the equipment and calls the name. Actual operation instruction for the equipment is inputted after confirmation by oral response. The voices of theses series of operation instruction/point-calling/response confirmation are taken into a voice recognition processing device. The processing device discriminates each of the person who calls, and discriminates the content of the calls and objective equipments to be operated. Then, the series of procedures and contents of the operation for the equipments previously disposed in the data base are compared with the order of inputted calls, discriminated contents and the objective equipments to be operated. If they are not agreed with each other, the operation instruction is blocked even if actual operation instructions are inputted. (I.S.)

  10. DEVELOPMENT OF THE TEMPERATURE CONTROL OF THE HOME-STREET AND MANAGING EXECUTIVE EQUIPMENT

    Directory of Open Access Journals (Sweden)

    Doshenko G.G.

    2017-12-01

    Full Text Available A home-street temperature control device and executive equipment management have been developed, which is characterized by high reliability and comparatively low cost. Due to the improvement of the analog circuit it is ensured to increase the speed of the developed device and its reliability. Practical recommendations for the manufacture of a home-street temperature control device and executive equipment management are presented

  11. "Do-It-Yourself" reliable pH-stat device by using open-source software, inexpensive hardware and available laboratory equipment.

    Science.gov (United States)

    Milanovic, Jovana Z; Milanovic, Predrag; Kragic, Rastislav; Kostic, Mirjana

    2018-01-01

    In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source "OpenPhControl" software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device's utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary.

  12. Benefits of Digital Equipment Generic Qualification Activities

    International Nuclear Information System (INIS)

    Thomas, James E.; Steiman, Samuel C.

    2002-01-01

    As a result of nuclear power plant instrumentation and control obsolescence issues, there have been numerous activities during recent years relating to the qualification of digital equipment. Some of these activities have been 'generic' in nature in that the qualification was not limited to plant specific applications, but was intended to cover a broad base of potential applications of the digital equipment. These generic qualifications have been funded by equipment manufacturers and by utility groups and organizations. The generic activities sponsored by the Electric Power Research Institute (EPRI) have been pilot projects for an overall generic qualification approach. The primary benefit resulting from the generic qualification work to date is that a number of digital platforms and digital devices are now available for use in various nuclear safety-related applications. Many of the tests and evaluations necessary to support plant specific applications have been completed. The amount of data and documentation that each utility must develop on a case by case basis has been significantly reduced. There are also a number of additional benefits resulting from these industry efforts. The challenges and difficulties in qualifying digital equipment for safety-related applications are now more clearly understood. EPRI has published a lessons learned document (EPRI Report 1001452, Generic Qualification of Commercial Grade Digital Devices: Lessons Learned from Initial Pilots, which covers several different qualification areas, including device selection, project planning, vendor surveys and design reviews, and electromagnetic compatibility (EMC) qualification. Application of the experience and lessons learned from the EPRI pilot activities should help reduce the effort and cost required for future qualification work. Most generic qualification activities for commercial equipment have been conducted using the approach of EPRI TR-106439, Guideline on Evaluation and Acceptance

  13. The development of special equipment amplitude detection instrument based on DSP

    International Nuclear Information System (INIS)

    Dai Sidan; Chen Ligang; Lan Peng; Wang Huiting; Zhang Liangxu; Wang Lin

    2014-01-01

    Development and industrial application of special equipment plays an important role in the development of nuclear energy process. Equipment development process need to do a lot of tests, amplitude detection is a key test,it can analysis the device's electromechanical and physical properties. In the industrial application, the amplitude detection can effectively reflect the operational status of the current equipment, the equipment can also be a certain degree of fault diagnosis, identify problems in a timely manner. The main development target in this article is amplitude detection of special equipment. This article describes the development of special equipment amplitude detection instrument. The instrument uses a digital signal processor (DSP) as the central processing unit, and uses the DSP + CPLD + high-speed AD technology to build a complete set of high-precision signal acquisition and analysis processing systems, rechargeable lithium battery as the powered device. It can do a online monitoring of special equipment amplitude, speed parameters by acquiring and analysing the tachometer signal in the special equipment, and locally display through the LCD screen. (authors)

  14. 40 CFR 63.2994 - How do I verify the performance of monitoring equipment?

    Science.gov (United States)

    2010-07-01

    ... equipment? (a) Before conducting the performance test, you must take the steps listed in paragraphs (a)(1) and (2) of this section: (1) Install and calibrate all process equipment, control devices, and... evaluation results. (b) If you use a thermal oxidizer, the temperature monitoring device must meet the...

  15. Hoisting appliances and fuel handling equipment at nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-31

    The guide is followed by the Finnish Centre for Radiation and Nuclear Safety (STUK) in regulating hoisting and handling equipment Class 3 at nuclear facilities. The guide is applied e.g. to the following equipment: reactor building overhead cranes, hoisting appliances at nuclear fuel storages, fuel handling machines, other hoisting appliances, which because of nuclear safety aspects are classified in Safety Class 3, and load-bearing devices connected with the above equipment, such as replaceable hoisting tools and auxiliary lifting devices. The regulating of hoisting and handling equipment comprises the following stages: handling of preliminary and final safety analysis reports, inspection of the construction plan, supervision of fabrication and construction inspection, and supervision of initial start-up and commissioning inspection. 36 refs. Translation. The original text is published under the same guide number. The guide is valid from 5 January 1987 and will be in force until further notice.

  16. 47 CFR 15.101 - Equipment authorization of unintentional radiators.

    Science.gov (United States)

    2010-10-01

    ... radiators. 15.101 Section 15.101 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY... initiation of marketing, as follows: Type of device Equipment authorization required TV broadcast receiver... external switching power supplies Verification. Other Class B digital devices & peripherals Verification...

  17. Common floor system vertical earthquake-proof structure for reactor equipment

    International Nuclear Information System (INIS)

    Morishita, Masaki.

    1996-01-01

    In an LMFBR type reactor, a reactor container, a recycling pump and a heat exchanger are disposed on a common floor. Vertical earthquake-proof devices which can be stretched only in vertical direction formed by laminating large-sized bellevilles are disposed on a concrete wall at the circumference of each of reactor equipments. A common floor is placed on all of the vertical earthquake-proof devices to support the entire earthquake-proof structure simultaneously. If each of reactor equipments is loaded on the common floor and the common floor is entirely supported against earthquakes altogether, since the movement of each of the reactor equipments loaded on the common floor is identical, relative dislocation is not exerted on the main pipelines which connect the equipments. In addition, since the entire earthquake structure has a flat common floor and each of the reactor equipments is suspended to minimize the distance between a gravitational center and a support point, locking vibration is less caused to the horizontal earthquake. (N.H.)

  18. Qualification of electric equipments for nuclear power plants

    International Nuclear Information System (INIS)

    Chauvin, G.; Raimondo, E.

    1983-03-01

    Description of the testing equipment, testing methods and standards of the resistance to seisms of electrical equipments (switches, pump motors, electrovalves, ...) for electronuclear power plants in France. Presentation of the French design and construction rules for electrical devices in the domestic and export nuclear market (resistance to thermodynamical and chemical stresses, to seisms, etc...) [fr

  19. The development of superconducting equipment

    CERN Document Server

    Ueda, T; Hiue, H

    2003-01-01

    Fuji Electric has been developing various types of superconducting equipment for over a quarter of a century. This paper describes the development results achieved for superconducting equipment and especially focuses on large-capacity current leads and superconducting transmission systems, the development of which is being promoted for application to the field of nuclear fusion. High temperature superconductor (HTS) is becoming the mainstream in the field of superconductivity, and the HTS floating coil and conduction-cooled HTS transformed are also introduced as recent developments for devices that utilize this technology. (author)

  20. "Do-It-Yourself" reliable pH-stat device by using open-source software, inexpensive hardware and available laboratory equipment

    Science.gov (United States)

    Kragic, Rastislav; Kostic, Mirjana

    2018-01-01

    In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source “OpenPhControl” software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device’s utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary. PMID:29509793

  1. 47 CFR 15.609 - Marketing of Access BPL equipment.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Marketing of Access BPL equipment. 15.609 Section 15.609 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Access Broadband Over Power Line (Access BPL) § 15.609 Marketing of Access BPL equipment. The marketing of Access...

  2. Underwater running device

    International Nuclear Information System (INIS)

    Kogure, Sumio; Matsuo, Takashiro; Yoshida, Yoji

    1996-01-01

    An underwater running device for an underwater inspection device for detecting inner surfaces of a reactor or a water vessel has an outer frame and an inner frame, and both of them are connected slidably by an air cylinder and connected rotatably by a shaft. The outer frame has four outer frame legs, and each of the outer frame legs is equipped with a sucker at the top end. The inner frame has four inner frame legs each equipped with a sucker at the top end. The outer frame legs and the inner frame legs are each connected with the outer frame and the inner frame by the air cylinder. The outer and the inner frame legs can be elevated or lowered (or extended or contracted) by the air cylinder. The sucker is connected with a jet pump-type negative pressure generator. The device can run and move by repeating attraction and releasing of the outer frame legs and the inner frame legs alternately while maintaining the posture of the inspection device stably. (I.N.)

  3. Information booklet on personal protective equipment: eye and face protection

    International Nuclear Information System (INIS)

    1992-01-01

    In all work places where hazards of various kinds are present and the same cannot be totally controlled by engineering methods, suitable personal protective equipment (PPE) shall be used. There are several types of eye and face protection devices available in the market and it is important that employees use the proper type for the particular job. The main classes of eye and face protection devices required for the industrial operations are as follows: (a) eye protection devices which includes: (i) safety goggles (ii) safety spectacles (iii) safety clipons and eye and face protection devices which are (i) eye shield, (ii) face shield, (iii) wire mesh screen guard. Guide lines for selecting appropriate ear and face protection equipment for nuclear installations are given. (M.K.V.). 4 annexures, 1 appendix

  4. After-hours power status of office equipment and energy use of miscellaneous plug-load equipment

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Marageret J.; Busch, John F.

    2004-05-27

    This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of miscellaneous plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. For most types of miscellaneous equipment, we also estimated typical unit energy consumption in order to estimate total energy consumption of the miscellaneous devices within our sample. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from sixteen commercial buildings in California, Georgia, and Pennsylvania: four education buildings, two medical buildings, two large offices (> 500 employees each), three medium offices (50-500 employees each), and five small

  5. After-hours Power Status of Office Equipment in the USA

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Carrie A.; Roberson, Judy A.; McWhinney, Marla C.; Brown,Richard E.; Pinckard, Margaret J.; Busch, John F.

    2005-10-13

    Office equipment is expected to be the fastest-growingsegment of commercial energy use over the next 20 years, yet many aspectsof office equipment energy use are poorly understood. User behavior, suchas turning off devices at night or enabling power management, influencesenergy use to a great extent. The computing environment also plays a roleboth in influencing user behavior and in the success of power management.Information about turn-off rates and power management rates for officeequipment was collected through a series of after-hours audits incommercial buildings. Sixteen businesses were recruited, includingoffices (small, medium and large offices in a variety of industries),schools, and medical buildings in California, Georgia, and Pennsylvania.The types and power states of office equipment found in these buildingswere recorded and analyzed. This article presents these data forcomputers, monitors, printers, copiers, fax machines, scanners andmulti-function devices. These data can be used to improve estimates ofboth energy consumption for these devices and savings from energyconservation efforts.

  6. A monitoring device for pressurised-air-driven diaphragm-based artificial heart assist devices

    NARCIS (Netherlands)

    Hoeben, F.P.; Hoeben, F.P.; de Mul, F.F.M.; Stokkink, J.S.D.; Stokkink, H.S.D.; Koelink, M.H.; Koelink, M.H.; Greve, Jan

    1992-01-01

    A non-invasive device has been developed to monitor the diaphragm position and the blood flow in artificial heart assist devices equipped with a pressurised-air-driven diaphragm. Light scattering from the diaphragm is used as a mechanism for measuring. Information about the position of several

  7. Origins of eponymous orthopaedic equipment.

    Science.gov (United States)

    Meals, Clifton; Wang, Jeffrey

    2010-06-01

    Orthopaedists make great use of eponymous equipment, however the origins of these tools are unknown to many users. This history enriches, enlightens, and enhances surgical education, and may inspire modern innovation. We explored the origins of common and eponymous orthopaedic equipment. We selected pieces of equipment named for their inventors and in the broadest use by modern orthopaedists. We do not describe specialized orthopaedic implants and instruments owing to the overwhelming number of these devices. The history of this equipment reflects the coevolution of orthopaedics and battlefield medicine. Additionally, these stories evidence the primacy of elegant design and suggest that innovation is often a process of revision and refinement rather than sudden inspiration. Their history exposes surgical innovators as brilliant, lucky, hardworking, and sometimes odd. These stories amuse, enlighten, and may inspire modern orthopaedists to develop creative solutions of their own. The rich history of the field's eponymous instruments informs an ongoing tradition of innovation in orthopaedics.

  8. Vapor generator equipped with a migrant body trapping device

    International Nuclear Information System (INIS)

    Pascal, Y.

    1994-01-01

    In a nuclear plant vapor generator, a device is foreseen to prevent objects coming from dryers, further to assembly, to subsequent interventions or to a fortuitous removal when operating, from coming jam between generator tubes. This device, which for example looks like a grid, is put above an horizontal plate to which are fixed the high ends of the pipes containing the cyclone separators. It determines crossings whose higher dimensions are lower to the minimal gap separating the tubes. (Author). 2 figs., 3 refs

  9. A device for reduction of metal oxides generated in electrokinetic separation equipment

    International Nuclear Information System (INIS)

    Kim, Gye-Nam; Kim, Seung-Soo; Kim, Il-Gook; Jeong, Jung-Whan; Choi, Jong-Won

    2015-01-01

    For a reduction of waste electrolyte volume and metal oxide volume, the reuse period of the waste electrolyte in the electrokinetic decontamination experiment and the method of a reduction of metal oxide volume in the cathode chamber were drawn out through several experiments with the manufactured 1.2 ton electrokinetic decontamination equipment. The optimum pH of electrolyte in cathode chamber for a reduction of volume of metal oxides was below 2.35. Indoor electrokinetic decontamination equipment for treatment of 1.2 tons of the contaminated soil per batch was manufactured to remove uranium from soil with high removal efficiency during a short time. For a reduction of waste electrolyte volume and metal oxide volume, the reuse period of waste electrolyte in the electrokinetic decontamination experiment and the method of a reduction of metal oxide volume in the cathode chamber were drawn out through several experiments with the manufactured electrokinetic equipment. Indoor electrokinetic decontamination equipment for treatment of 1.2 tons of the contaminated soil was manufactured to remove uranium from soil during a short time

  10. A device for reduction of metal oxides generated in electrokinetic separation equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gye-Nam; Kim, Seung-Soo; Kim, Il-Gook; Jeong, Jung-Whan; Choi, Jong-Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    For a reduction of waste electrolyte volume and metal oxide volume, the reuse period of the waste electrolyte in the electrokinetic decontamination experiment and the method of a reduction of metal oxide volume in the cathode chamber were drawn out through several experiments with the manufactured 1.2 ton electrokinetic decontamination equipment. The optimum pH of electrolyte in cathode chamber for a reduction of volume of metal oxides was below 2.35. Indoor electrokinetic decontamination equipment for treatment of 1.2 tons of the contaminated soil per batch was manufactured to remove uranium from soil with high removal efficiency during a short time. For a reduction of waste electrolyte volume and metal oxide volume, the reuse period of waste electrolyte in the electrokinetic decontamination experiment and the method of a reduction of metal oxide volume in the cathode chamber were drawn out through several experiments with the manufactured electrokinetic equipment. Indoor electrokinetic decontamination equipment for treatment of 1.2 tons of the contaminated soil was manufactured to remove uranium from soil during a short time.

  11. Auxiliary cooling device for power plant

    International Nuclear Information System (INIS)

    Yamanoi, Kozo.

    1996-01-01

    An auxiliary cooling sea water pipeline for pumping up cooling sea water, an auxiliary cooling sea water pipeline and a primary side of an auxiliary cooling heat exchanger are connected between a sea water taking vessel and a sea water discharge pit. An auxiliary cooling water pump is connected to an auxiliary water cooling pipeline on the second side of the auxiliary cooling heat exchanger. The auxiliary cooling water pipeline is connected with each of auxiliary equipments of a reactor system and each of auxiliary equipments of the turbine system connected to a turbine auxiliary cooling water pipeline in parallel. During ordinary operation of the reactor, heat exchange for each of the auxiliary equipments of the reactor and heat exchange for each of the equipments of the turbine system are conducted simultaneously. Since most portions of the cooling devices of each of the auxiliary equipments of the reactor system and each of the auxiliary equipments of the turbine system can be used in common, the operation efficiency of the cooling device is improved. In addition, the space for the pipelines and the cost for the equipments can be reduced. (I.N.)

  12. Generic testability and test methods guidelines for ASIC devices

    International Nuclear Information System (INIS)

    Puri, K.; Takeda, H.

    1996-04-01

    Many industries are switching from analog equipment to digital equipment. This change has become desirable because digital devices have become cost-effective, easily available, highly reliable, easy to qualify and easy to test and replace when needed. The nuclear power industry is beginning to upgrade some of its instrumentation and control equipment from an analog design to digital design. A digital application specific integrated circuit (ASIC) device can be designed to perform the same functions as performed by analog modules. However, the ASIC must be designed for cost-effective testability and qualification. This report provides generic guidelines for designing cost-effective methods for testing and characterizing ASIC devices to accomplish qualification

  13. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  14. 14 CFR 25.1357 - Circuit protective devices.

    Science.gov (United States)

    2010-01-01

    ... system or connected equipment. (b) The protective and control devices in the generating system must be designed to de-energize and disconnect faulty power sources and power transmission equipment from their...

  15. Equipment and special tool design for remote maintenance

    International Nuclear Information System (INIS)

    Northey, L.M.; Thomson, J.D.

    1985-01-01

    Maintenance tasks performed in locations with hostile environments and/or limited space accesses often require equipment that is operated remotely. This paper discusses considerations that should be addressed in the design of remote maintenance equipment. Some of the topics include proper material selection, interface identifications, operational feedback devices and cost limitations. These considerations add ''human engineering'' to the equipment design to assure protection of the tool and the operating personnel. Examples of remote maintenance and inspection systems that were developed by the Westinghouse Hanford Company and that utilize many of these design considerations are included

  16. Just a piece of equipment? The importance of medical device education.

    Science.gov (United States)

    Brand, Darren

    2012-12-01

    The use of medical devices is an increasingly important element of a healthcare professional's role. It is crucial that users receive regular teaching and education to ensure that they are competent in the use of devices. This is particularly relevant in the increasingly litigious society in which we live. This article focuses upon the importance of a medical device education.

  17. Radioactive decontamination of equipment

    International Nuclear Information System (INIS)

    1982-03-01

    After a recall of some definitions relating to decontamination techniques and of the regulation into effect, the principles to be respected to arrange rationally work zones are quoted while insisting more particularly on the types of coatings which facilitate maintenance operations and the dismantling of these installations. Then, the processes and equipments to use in decontamination units for routine or particular operations are described; the list of recommended chemical products to decontaminate the equipment is given. The influence of these treatments on the state and the duration of life of equipments is studied, and some perfectible methods are quoted. In the appendix, are given: the limits of surface contamination accepted in the centers; a standard project which defines the criteria of admissible residual contamination in wastes considered as cold wastes; some remarks on the interest that certain special ventilation and air curtain devices for the protection of operators working on apparatus generating contaminated dusts [fr

  18. Equipment for collecting samples of radioactive solutions

    International Nuclear Information System (INIS)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-01-01

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described

  19. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    International Nuclear Information System (INIS)

    Murata, C.H.; Fernandes, D.C.; Lavínia, N.C.; Caldas, L.V.E; Pires, S.R; Medeiros, R.B.

    2014-01-01

    a multifunctional instrument that can appropriately evaluate the performance of radiological equipment. - Highlights: • An instrument was developed to evaluate the performance of radiological equipment. • The prototype containing solid detector was compared with commercial instruments. • The prototype device shows comparable reproducibility and accuracy with commercial instruments. • The prototype can be used for evaluate kVp, exposure time, and HVL using a single X-ray exposure

  20. Radiology equipment maintenance and contract procurement in the UK.

    Science.gov (United States)

    Wright, Christopher J

    2012-01-01

    Radiology equipment maintenance has a similar financial value to new device acquisition over the lifetime of the device. Comprehensive style contracts are dominant largely due to their ease of use and the potential to control budgetary costs, but costs are high. Creative procurement solutions can offer better value. The corrective portion of comprehensive contracts is estimated to be between 50% (Mobile C-Arm) to 92% (CT), which equates to $29.4 million; 80% of the total contract costs within the research population of this study. Many organizations could free up cash by better managing their maintenance costs, potentially creating funding opportunities for new equipment.

  1. QoE-Aware Device-to-Device Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Liang ZHOU

    2015-08-01

    Full Text Available Multimedia services over mobile device-to-device (D2D networks has recently received considerable attention. In this scenario, each device is equipped with a cellular communication interface, as well as a D2D interface over a shared medium. In this work, we study the performance properties of the mobile D2D communications in the framework of user satisfaction, and develop a fully distributed QoE-aware multimedia communication scheme (QAMCS. Specifically, we translate the opportunistic multimedia communications issue into a stochastic optimization problem, which opens up a new degree of performance to exploit. Moreover, QAMCS is designed for a heterogeneous and dynamic environment, in which user demand, device mobility, and transmission fashion may vary across different devices and applications. Importantly, QAMCS is able to maximize the user satisfaction and only needs each device to implement its own scheme individually in the absence of a central controller.

  2. Oil leakage detection for electric power equipment based on ultraviolet fluorescence effect

    Science.gov (United States)

    Zhang, Jing; Wang, Jian-hui; Xu, Bin; Huang, Zhi-dong; Huang, Lan-tao

    2018-03-01

    This paper presents a method to detect the oil leakage of high voltage power equipment based on ultraviolet fluorescence effect. The method exploits the principle that the insulating oil has the fluorescent effect under the irradiation of specific ultraviolet light. The emission spectrum of insulating oil under excitation light with different wavelengths is measured and analyzed first. On this basis, a portable oil leakage detective device for high voltage power equipment is designed and developed with a selected 365 nm ultraviolet as the excitation light and the low light level camera as the fluorescence image collector. Then, the feasibility of the proposed method and device in different conditions is experimentally verified in the laboratory environment. Finally, the developed oil leakage detective device is applied to 500 kV Xiamen substation and Quanzhou substation. And the results show that the device can detect the oil leakage of high voltage electrical equipment quickly and conveniently even under the condition of a slight oil leakage especially in the low light environment.

  3. Electromedical devices test laboratories accreditation

    International Nuclear Information System (INIS)

    Murad, C; Rubio, D; Ponce, S; Alvarez Abri, A; Terron, A; Vicencio, D; Fascioli, E

    2007-01-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University

  4. Development of maintenance equipment for nuclear material fabrication equipment in a highly active hot cell

    International Nuclear Information System (INIS)

    Park, J. J.; Yang, M. S.; Kim, K. H. and others

    2000-09-01

    This report presents the development of a maintenance system for a highly contaminated nuclear material handling equipment at a hot-cell. This maintenance system has mainly three subsystems - a gamma-radiation measurement module for detecting a gamma-radiation level and identifying its distribution in-situ, a dry-type decontamination device for cleaning up contaminated particles, and a maintenance chamber for isolating contaminated equipment. The mechanical design considerations, controller, capabilities and remote operation and manipulation of the maintenance system are described. Such subsystems developed were installed and tested in the IMEF (Irradiated Material Examination Facility) M6 hot-cell after mock-up tests and performed their specific tasks successfully

  5. Development of maintenance equipment for nuclear material fabrication equipment in a highly active hot cell

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. J.; Yang, M. S.; Kim, K. H. and others

    2000-09-01

    This report presents the development of a maintenance system for a highly contaminated nuclear material handling equipment at a hot-cell. This maintenance system has mainly three subsystems - a gamma-radiation measurement module for detecting a gamma-radiation level and identifying its distribution in-situ, a dry-type decontamination device for cleaning up contaminated particles, and a maintenance chamber for isolating contaminated equipment. The mechanical design considerations, controller, capabilities and remote operation and manipulation of the maintenance system are described. Such subsystems developed were installed and tested in the IMEF (Irradiated Material Examination Facility) M6 hot-cell after mock-up tests and performed their specific tasks successfully.

  6. 42 CFR 410.38 - Durable medical equipment: Scope and conditions.

    Science.gov (United States)

    2010-10-01

    ... or purchase of durable medical equipment, including iron lungs, oxygen tents, hospital beds, and wheelchairs, if the equipment is used in the patient's home or in an institution that is used as a home. (b... vehicle whose steering is operated by an electronic device or a joystick to control direction and turning...

  7. Diagnostic X-ray equipment evaluation in Brazil

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Peixoto, J.E.; Reis, V.R.G.

    1980-01-01

    A survey of the diagnostic X-ray equipment in use in Brazil is presented. Procedures for testing radiation quality (kilovoltage and filtration), tube output, beam collimation and protection devices are described and results of tests are tabulated. (H.K.)

  8. Device for overlapping of a column of pump compressor pipes

    Energy Technology Data Exchange (ETDEWEB)

    Sharafutdinov, I.G.; Akhmerov, M.N.; Asadullin, Kh.F.; Prokopov, O.I.

    1980-02-16

    A device is proposed for automatic overlapping of pump compressor pipes of gushing petroleum and gas wells when losses occur near the well. The objective of the invention is to increase efficiency of the overlapping of the pipe column by recharging the device directly at the hole without disassembling the head equipment. This objective is achieved as follows. The device is equipped with elastic spacers located in the channels of a ring. They are mounted with the possibility of interaction with ball catches. A drawing and description of the device are given.

  9. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  10. Firewood preparation devices in 1994

    International Nuclear Information System (INIS)

    Mutikainen, A.

    1994-01-01

    A review of the market situation regarding firewood preparation devices is presented. The information was collected from the answers to a mail questionnaire. The review is assumed to include all the leading manufacturers and importers. Firewood production devices were available from 26 manufacturers. The range of models amounted to over 70. These may be divided into three categories: 1. cutting devices: the most common solution being a cross-cutting circular saw. There were only a few of these on sale as it is quite easy to include a splitting device on the same frame. 2. Splitting devices: e.g. screw splitter and hydraulically powered splitter. About 20 models are available on the markets. Cross cutting and splitting devices: these are the most popular devices. A cross-cutting circular saw with screw or hydraulic splitter is the most common type. There are about 50 models available on the markets. Cross-cutting and splitting devices are often equipped with conveyor for transferring the split wood e.g. into a trailer. Chopping devices are delivered as tractor powered devices, as electric motor powered devices or as combustion engine powered devices. Some of them are equipped with a time saving feeding device enabling the next stem to be lifted into position while the previous one is being chopped. The Finnish Work Efficiency Institute's studies show that when cross-cutting and splitting of stems into pieces of 35-50 cm in length, productivity for one operator varies in between 0.8 - 3.2 m 3 /h, depending on the device and work method used. (6 refs., 1 fig., 2 tabs.)

  11. Lists A and B of X-ray equipment. As of July 1, 1984

    International Nuclear Information System (INIS)

    1984-01-01

    The lists A and B of X-ray equipment present the guidelines for X-ray device, as of December 10, 1983, that are defined in the guidelines for radiology and nuclear medicine of the Federal Association of Panel Doctors. In list A, the equipment categories of up-to-date, commercially available X-ray device are given, whereas list B classifies older equipment, both types available from manufacturers who are members of the ZVEI association. Since the categories of application II and III have been made, specifiying the equipment still in use and applicable within a given transitional period in existing medical establishments, but which may not be applied in new establishments. The list of manufacturers gives the addresses of the firms supplying the equipment described in Lists A and B, which have been compiled according to the requirements set by the Federal Association of Panel Doctors. (orig.) [de

  12. 46 CFR 184.704 - Marine sanitation devices.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Marine sanitation devices. 184.704 Section 184.704... TONS) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.704 Marine sanitation devices. A vessel with installed toilet facilities must have a marine sanitation device that complies with...

  13. Building Evacuation with Mobile Devices

    OpenAIRE

    Merkel, Sabrina

    2014-01-01

    The rapidly growing world population and increasingly dense settlements demand ever-larger and more complex buildings from today's engineers. In comparison to this technological progress, a building's equipment for emergency evacuation has been hardly developed further. This work presents a concept for a building evacuation system based on mobile devices. Furthermore, various algorithms for route planning with mobile devices and for indoor localization of mobile devices are addressed.

  14. 46 CFR 121.704 - Marine sanitation devices.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Marine sanitation devices. 121.704 Section 121.704... MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 121.704 Marine sanitation devices. A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159. [CGD 85-080...

  15. Mechanical equipment for magnet measurement and alignment

    International Nuclear Information System (INIS)

    Harvey, A.

    1992-05-01

    The mechanical equipment for measuring and aligning (or fiducializing) magnets is described by reference to devices designed and built by a number of laboratories. Some of these are now available commercially. The descriptions are supplemented by a list of representative sources of hardware

  16. Process control device

    International Nuclear Information System (INIS)

    Hayashi, Toshifumi; Kobayashi, Hiroshi.

    1994-01-01

    A process control device comprises a memory device for memorizing a plant operation target, a plant state or a state of equipments related with each other as control data, a read-only memory device for storing programs, a plant instrumentation control device or other process control devices, an input/output device for performing input/output with an operator, and a processing device which conducts processing in accordance with the program and sends a control demand or a display demand to the input/output device. The program reads out control data relative to a predetermined operation target, compares and verify them with actual values to read out control data to be a practice premise condition which is further to be a practice premise condition if necessary, thereby automatically controlling the plant or requiring or displaying input. Practice presuming conditions for the operation target can be examined succesively in accordance with the program without constituting complicated logical figures and AND/OR graphs. (N.H.)

  17. Message Oriented Communication For Ipv6 Enabled Pervasive Devices

    Directory of Open Access Journals (Sweden)

    Tomasz Szydlo

    2013-01-01

    Full Text Available An increasing number of electronic devices in our environment is equipped with radio interfaces used for exposing and using their functionality by other devices and applications. Wireless communication in this class of devices is exposed to a number of situations that may occur including limited energy resources, equipment failures, nodes mobility and loss of communication between nodes. It causes that commonly used standards and protocols for sharing services are not practical and do not take into account the occurrence of these problems. The paper presents the concept of communication that relies on the exchange of messages between wireless pervasive devices available in the environment.

  18. Electronic Equipment of Self-Actuated Mobile Device for Load Carrying

    Directory of Open Access Journals (Sweden)

    T. Janecka

    1994-12-01

    Full Text Available The device dealt in this work is determined namely for carrying invalid persons on various types of stairs or other not flat surfaces. But it can serve also to other purposes.To enable fulfilling all given demands, the design was consulted with other research workers solving the tasks of similar features.Resulting mechanical device, enabling aspects of movement required, is controlled by electronic and microprocessor circuits that obtain the input information from sensitive units investigating the terrain.

  19. SOR/72-43 Radiation Emitting Devices Regulations

    International Nuclear Information System (INIS)

    1972-01-01

    These Regulations of 10 February 1972, supplemented by SOR/77-895, lay down the classes of radiation emitting devices for the purposes of the Radiation Emitting Devices Act. They lay down their standards of design and construction and warning sign specifications and provide for the procedure to be followed by inspectors of such devices. The devices include inter alia extra-oral dental x-ray equipment, baggage inspection x-ray devices, laser scanners, television receivers. (NEA)

  20. Gate protective device for SOS array

    Science.gov (United States)

    Meyer, J. E., Jr.; Scott, J. H.

    1972-01-01

    Protective gate device consisting of alternating heavily doped n(+) and p(+) diffusions eliminates breakdown voltages in silicon oxide on sapphire arrays caused by electrostatic discharge from person or equipment. Diffusions are easily produced during normal double epitaxial processing. Devices with nine layers had 27-volt breakdown.

  1. Evidence for the safety assurance of the radiation associated equipments for stat-up check

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Igarashi, Hiroshi; Saito, Kyoko; Kawaharada, Yasuhiro; Hirano, Kunihiro; Murase, Kenya; Mochizuki, Teruhito

    2008-01-01

    Based on the new amendment of the Medical Service Law and the Pharmaceutical Affairs Law, the safety control for the medical equipments and devices was strengthened; and a radiological technologist should be stipulated as a safety control manager for the medical equipments and devices. Although it is thought that Start-up check is important for the safety assurance, the enforcement situation is not clear until now. In this report, on the occasion of the start-up of the new Law, questionnaire about the start up check (time and a check items) were investigated from 56 hospitals applying the visit interview. Modality by modality check up time was obtained from 261 institutions by the descriptive study paper type. Start-up check and arming up were applied for almost all modalities about 30 minutes before start of the clinical tests. The check up items for the medical equipments and devices depended on each hospital. Therefore, safety assurance should be established, cooperating with the medical equipment distributors, the hospital sharing the checked results for the patients' safety. (author)

  2. 46 CFR 130.220 - Design of equipment for cooking and heating.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Design of equipment for cooking and heating. 130.220... Design of equipment for cooking and heating. (a) Doors on each cooking appliance must be provided with heavy-duty hinges and locking-devices to prevent accidental opening in heavy weather. (b) Each cooking...

  3. Equipment for evaluation of the characteristics of electronic-optic converters

    International Nuclear Information System (INIS)

    Getsov, Petar; Mardirossian, Garo; Nedkov, Rumen; Stoyanov, Stiliyan; Bo, Wang; Prokopenko, Olga; Boyanov, Petar

    2018-01-01

    In this paper we consider the concept, structure, operation and application of original equipment for evaluation of the characteristics of electronic-optic converters (EOC) created in the Space Research and Technologies Institute at the Bulgarian Academy of Sciences. The equipment is recognized as an invention and it is subject to patent protection. Key words: electronic-optic converter, infrared radiation, night surveillance devices

  4. Satellite and acoustic tracking device

    KAUST Repository

    Berumen, Michael L.

    2014-02-20

    The present invention relates a method and device for tracking movements of marine animals or objects in large bodies of water and across significant distances. The method and device can track an acoustic transmitter attached to an animal or object beneath the ocean surface by employing an unmanned surface vessel equipped with a hydrophone array and GPS receiver.

  5. Satellite and acoustic tracking device

    KAUST Repository

    Berumen, Michael L.; De la Torre, Pedro

    2014-01-01

    The present invention relates a method and device for tracking movements of marine animals or objects in large bodies of water and across significant distances. The method and device can track an acoustic transmitter attached to an animal or object beneath the ocean surface by employing an unmanned surface vessel equipped with a hydrophone array and GPS receiver.

  6. Hydraulic turbines and auxiliary equipment

    Energy Technology Data Exchange (ETDEWEB)

    Luo Gaorong [Organization of the United Nations, Beijing (China). International Centre of Small Hydroelectric Power Plants

    1995-07-01

    This document presents a general overview on hydraulic turbines and auxiliary equipment, emphasizing the turbine classification, in accordance with the different types of turbines, standard turbine series in China, turbine selection based on the basic data required for the preliminary design, general hill model curves, chart of turbine series and the arrangement of application for hydraulic turbines, hydraulic turbine testing, and speed regulating device.

  7. Bilateral tension pneumothorax following equipment improvisation.

    Science.gov (United States)

    Zambricki, Christine; Schmidt, Carol; Vos, Karen

    2014-02-01

    This case report describes an unexpected event that took place as a result of using improvised equipment. The patient, a 16-year-old female undergoing complex oral surgery, suffered bilateral pneumothorax following the improper use of an airway support device. During the immediate postoperative period with the patient still intubated, oxygen tubing was attached to a right angle elbow connector with the port closed and 10 L/minute oxygen flow was administered to the patient in a manner that did not allow the patient to exhale. Within seconds, pneumothorax was apparent as the patient's vital signs deteriorated, visible swelling was noted in the shoulders and neck, and there was an absence of breath sounds on auscultation. This case study has application beyond the immediate discussion of bilateral pneumothorax, serving as a caution about the unintended consequences of equipment improvisation. In addition to highlighting the hazards of providing patient care with a non-standard device, this study also provides a powerful example of the human factors that can contribute to medical errors in the healthcare setting.

  8. Synthesis of securement device options and strategies

    Science.gov (United States)

    2002-03-01

    The Americans with Disabilities Act of 1990 (ADA) requires that public transit vehicles be equipped with securement location(s) and device(s) that are able to secure common wheelchairs," as defined in the ADA regulations. The definition and size spec...

  9. 21 CFR 864.2240 - Cell and tissue culture supplies and equipment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cell and tissue culture supplies and equipment. 864.2240 Section 864.2240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Cell And Tissue Culture Products...

  10. NASA safety standard for lifting devices and equipment

    Science.gov (United States)

    1990-09-01

    NASA's minimum safety requirements are established for the design, testing, inspection, maintenance, certification, and use of overhead and gantry cranes (including top running monorail, underhung, and jib cranes), mobile cranes, derrick hoists, and special hoist supported personnel lifting devices (these do not include elevators, ground supported personnel lifts, or powered platforms). Minimum requirements are also addressed for the testing, inspection, and use of Hydra-sets, hooks, and slings. Safety standards are thoroughly detailed.

  11. Self-centering and damping capabilities of a tension-compression device equipped with superelastic NiTi wires

    International Nuclear Information System (INIS)

    Soul, H; Yawny, A

    2015-01-01

    The hysteretic damping capacity and high recoverable strains characterizing the superelastic response of shape memory alloys (SMA) make these materials attractive for protection systems of structures subjected to dynamic loads. A successful implementation however is conditioned by functional fatigue exhibited by the SMA when subjected to cyclic loading. The residual deformation upon cycling and the efficiency in material usage are the two most restrictive issues in this sense. In this paper, a device equipped with superelastic NiTi SMA wires and capable of supporting external tension compression loads with optimized properties is presented. It is shown how the introduction of the wires’ pre-straining allows for the absorption of deleterious residual deformation without affecting the self-centering capabilities upon unloading, in contrast with what occurs for pre-strained tendons. These features were experimentally verified in an in-scale prototype composed of two 1.2 mm diameter superelastic NiTi SMA wires. In order to numerically assess the dynamic response of a simple structure subjected to seismic excitations, a multilinear superelasticity model for the NiTi wires was developed. (paper)

  12. Repair and managing device in nuclear power plants

    International Nuclear Information System (INIS)

    Shinzawa, Katsuo.

    1982-01-01

    Purpose: To moderate the operator's labour by automatically carrying out the managing works for the repair of nuclear power plants. Constitution: Information concerning the content of the repair works inputted from an input device is arranged and analyzed in a calculation device and judged if it is the content for a format work or not. The calculation device has a function of extracting the information regarding the format work content from the memory device and comparing the plant information from the reading device before the repair work and after the recovering work. A printer connected to the output end of the calculation device issues an information regarding the format work content extracted from the memory device, that is, written work procedures and operation inhibition TAG. The content, period, person in charge, purpose, allowed items and the likes for the works are printed on the operation inhibition TAG. After the operation for the equipments, one half of them is charged to the equipment and the other half of them is charged to the reading device and the plant information is sent to the memory device. (Kawakami, Y.)

  13. Utilization technique on variable speed device

    International Nuclear Information System (INIS)

    1989-12-01

    This reports of workshop on power technology describes using technique on variable speed device, which deals with alternating current situation and prospect of current variable speed device, technical trend and prospect of electronics, reduce expenses by variable speed device, control technique, measurement technology, high voltage variable speed device, recent trend of inverter technology, low voltage and high voltage variable speed device control device, operating variable speed device in cooling fan, FDF application and defect case of variable speed device, cooling pump application of water variable transformer, inverter application and energy effect of ventilation equipment, application of variable speed device and analysis of the result of operation and study for application of variable speed technology.

  14. Are wearable devices ready for HTTPS? Measuring the cost of secure communication protocols on wearable devices

    OpenAIRE

    Kolamunna, Harini; Chauhan, Jagmohan; Hu, Yining; Thilakarathna, Kanchana; Perino, Diego; Makaroff, Dwight; Seneviratne, Aruna

    2016-01-01

    The majority of available wearable devices require communication with Internet servers for data analysis and storage, and rely on a paired smartphone to enable secure communication. However, wearable devices are mostly equipped with WiFi network interfaces, enabling direct communication with the Internet. Secure communication protocols should then run on these wearables itself, yet it is not clear if they can be efficiently supported. In this paper, we show that wearable devices are ready for...

  15. Photometric device using optical fibers

    International Nuclear Information System (INIS)

    Boisde, Gilbert; Perez, J.-J.

    1981-02-01

    Remote measurements in radioactive environment are now possible with optical fibers. Measurement instruments developed by CEA are constitued of: - an optical probe (5 mm to 1 meter optical path length), - a photometric measurement device, - optical fiber links. 'TELEPHOT' is a photometric device for industrial installations. It is uses interferentiel filters for 2 to 5 simultaneous wave lengths. 'CRUDMETER' measures the muddiness of water. It can be equipped with a high sensitivity cell of 50 cm optical path length tested up to 250 bars. Coupling a double beam spectrophotometer to a remote optical probe, up to 1 meter optical path length, is carried out by means of an optical device using optical fibers links, eventually several hundred meter long. For these equipments special step index large core fibers, 1 to 1.5 mm in diameter, have been developed as well connectors. For industrial control and research these instruments offer new prospect thanks to optical fibers use [fr

  16. 30 CFR 18.48 - Circuit-interrupting devices.

    Science.gov (United States)

    2010-07-01

    ... energized. (f) Belt conveyors shall be equipped with control switches to automatically stop the driving motor in the event the belt is stopped, or abnormally slowed down. Note: Short transfer-type conveyors... Design Requirements § 18.48 Circuit-interrupting devices. (a) Each machine shall be equipped with a...

  17. MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT. NATIONAL SANITATION FOUNDATION STANDARD NO. 18.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    THIS STANDARD COVERS THE SANITATION REQUIREMENTS FOR EQUIPMENT AND DEVICES WHICH DISPENSE FOOD OR BEVERAGE EITHER IN BULK OR PORTIONS. VENDING MACHINES OR BULK MILK DISPENSING EQUIPMENT ARE NOT COVERED IN THIS STANDARD. ITEMS COVERED INCLUDE THE BASIC PRINCIPLES OF DESIGN AND CONSTRUCTION, FOOD PROTECTION AND FREEDOM FROM HARBORAGES. MINIMUM…

  18. Method for lowering explosives into a well and hoisting the equipment therefrom

    Energy Technology Data Exchange (ETDEWEB)

    Grigoryan, N G; Gushchin, N I; Fridlyander, L Ya; Vitseni, E M

    1962-06-05

    In order to lower the cost and simplifying the shooting and explosives procedure, the explosives and other equipment are lowered into a well on a wire line by means of their own weight. The hoisting of the shooting equipment is accomplished by means of a reactive engine attached to the device.

  19. 13 CFR 120.331 - What devices or techniques are eligible for a loan?

    Science.gov (United States)

    2010-01-01

    ... BUSINESS LOANS Special Purpose Loans Energy Conservation § 120.331 What devices or techniques are eligible for a loan? Eligible energy conservation devices or techniques include: (a) Solar thermal equipment... heating or production of energy from industrial waste; (f) Hydroelectric power equipment; (g) Wind energy...

  20. Assessing the Oldness and Capacity of Radiography and Ultrasound Equipments in Tehran University of Medical Sciences

    International Nuclear Information System (INIS)

    Salamati, Payman; Ghanaati, Hossein; Ghasemzadeh, Shahram; Jalali, Amir Hossein

    2013-01-01

    Maintenance of imaging equipment is a very important part of the management of all medical imaging centers. To assess the oldness and capacity of radiography and ultrasound equipment in Tehran University of Medical Sciences. The study was performed in 16 hospitals, 4 faculties and three healthcare centers of Tehran University of Medical Sciences. We evaluated all the X-ray equipment (including the simple plain and dental, panorex, mammography, fluoroscopy and C-arm X-Ray devices) and also simple and Doppler ultrasound machines in terms of the type and usage of the device, production year, quantity of utilization, location, brand and current condition. Among fixed X-ray systems, 15 were currently in use, two were junk, two were damaged, and one was not utilized. The mean (SD) of the usage of these was 2151 (2230) cliché/month, and the mean (SD) of the oldness was 16.9 (13.6) years. The oldness of radiography equipment in our study was more than 20 years in 16, between 11 and 20 in 46, and less than 10 years in 76 devices. The mean (SD) usage (patients/month) of simple and color Doppler devices were 234.1 (365.2) and 597.5 (505.3), respectively. The oldness of ultrasonography equipment in our study was more than 11 years in 12 and less than 10 years in 55 devices. We found that 22 (15.9%) of the radiography systems and two (3%) of the ultrasonography systems had been used for more than 20 years. Radiology equipment in Tehran University of Medical Sciences have potential capacity, but they need repair, and better maintenance and management and application of standards for the imaging system needs organized supervisory mechanisms

  1. 30 CFR 250.511 - Traveling-block safety device.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Traveling-block safety device. 250.511 Section... Traveling-block safety device. All units being used for well-completion operations that have both a traveling block and a crown block must be equipped with a safety device that is designed to prevent the...

  2. 46 CFR 28.260 - Electronic position fixing devices.

    Science.gov (United States)

    2010-10-01

    ... Trade § 28.260 Electronic position fixing devices. Each vessel 79 feet (24 meters) or more in length must be equipped with an electronic position fixing device capable of providing accurate fixes for the... 46 Shipping 1 2010-10-01 2010-10-01 false Electronic position fixing devices. 28.260 Section 28...

  3. High heat flux device of thermonuclear device

    International Nuclear Information System (INIS)

    Tachikawa, Nobuo.

    1994-01-01

    The present invention provides an equipments for high heat flux device (divertor) of a thermonuclear device, which absorbs thermal deformation during operation, has a high installation accuracy, and sufficiently withstands for thermal stresses. Namely, a heat sink member is joined to a structural base. Armour tiles are joined on the heat sink member. Cooling pipes are disposed between the heat sink member and the armour tiles. With such a constitution, the heat sink member using a highly heat conductive material having ductility, such as oxygen free copper, the cooling pipes using a material having excellent high temperature resistance and excellent elongation, such as aluminum-dispersed reinforced copper, and the armour tiles are completely joined on the structural base. Therefore, when thermal deformation tends to cause in the high heat flux device such as a divertor, cooling pipes cause no plastic deformation because of their high temperature resistance, but the heat sink member such as a oxygen free copper causes plastic deformation to absorb thermal deformation. As a result, the high heat flux device such as a divertor causes no deformation. (I.S.)

  4. Influence of various parameters on effectiveness of seismic base isolation of nuclear equipment

    International Nuclear Information System (INIS)

    Ebisawa, K.; Kameoka, H.; Takenouchi, I.; Kajiki, S.

    1995-01-01

    Authors developed a methodology and EBISA code for evaluating the applicability and the effectiveness of seismic base isolation of nuclear equipment. In order to investigate the influence of various parameters on the effectiveness of seismic base isolation, a sensitivity analysis was carried out for an emergency transformer with the base isolation devices. It was proved that seismic base isolation of equipment is very effective. This effectiveness can be influenced by the differences of the base isolation devices and the direction of the input seismic wave. (author). 7 refs., 3 figs., 3 tabs

  5. Safety status system for operating room devices.

    Science.gov (United States)

    Guédon, Annetje C P; Wauben, Linda S G L; Overvelde, Marlies; Blok, Joleen H; van der Elst, Maarten; Dankelman, Jenny; van den Dobbelsteen, John J

    2014-01-01

    Since the increase of the number of technological aids in the operating room (OR), equipment-related incidents have come to be a common kind of adverse events. This underlines the importance of adequate equipment management to improve the safety in the OR. A system was developed to monitor the safety status (periodic maintenance and registered malfunctions) of OR devices and to facilitate the notification of malfunctions. The objective was to assess whether the system is suitable for use in an busy OR setting and to analyse its effect on the notification of malfunctions. The system checks automatically the safety status of OR devices through constant communication with the technical facility management system, informs the OR staff real-time and facilitates notification of malfunctions. The system was tested for a pilot period of six months in four ORs of a Dutch teaching hospital and 17 users were interviewed on the usability of the system. The users provided positive feedback on the usability. For 86.6% of total time, the localisation of OR devices was accurate. 62 malfunctions of OR devices were reported, an increase of 12 notifications compared to the previous year. The safety status system was suitable for an OR complex, both from a usability and technical point of view, and an increase of reported malfunctions was observed. The system eases monitoring the safety status of equipment and is a promising tool to improve the safety related to OR devices.

  6. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment; Desenvolvimento de um dispositivo artesanal para os testes de colimação e alinhamento do raio central em equipamentos médicos de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S., E-mail: elizabethberbr@live.com [Universidade José de Souza Herdy (UNINGRANRIO), Nova Iguaçu, RJ (Brazil)

    2017-07-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden.

  7. 30 CFR 250.611 - Traveling-block safety device.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Traveling-block safety device. 250.611 Section... Traveling-block safety device. After May 31, 1989, all units being used for well-workover operations which have both a traveling block and a crown block shall be equipped with a safety device which is designed...

  8. 21 CFR 862.2050 - General purpose laboratory equipment labeled or promoted for a specific medical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false General purpose laboratory equipment labeled or... TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2050 General purpose laboratory equipment labeled or promoted for a specific medical use. (a) Identification. General purpose laboratory equipment labeled or...

  9. Quantifying Pollutant Emissions from Office Equipment Phase IReport

    Energy Technology Data Exchange (ETDEWEB)

    Maddalena, R.L.; Destaillats, H.; Hodgson, A.T.; McKone, T.E.; Perino, C.

    2006-12-01

    Although office equipment has been a focal point for governmental efforts to promote energy efficiency through programs such as Energy Star, little is known about the relationship between office equipment use and indoor air quality. This report provides results of the first phase (Phase I) of a study in which the primary objective is to measure emissions of organic pollutants and particulate matter from a selected set of office equipment typically used in residential and office environments. The specific aims of the overall research effort are: (1) use screening-level measurements to identify and quantify the concentrations of air pollutants of interest emitted by major categories of distributed office equipment in a controlled environment; (2) quantify the emissions of air pollutants from generally representative, individual machines within each of the major categories in a controlled chamber environment using well defined protocols; (3) characterize the effects of ageing and use on emissions for individual machines spanning several categories; (4) evaluate the importance of operational factors that can be manipulated to reduce pollutant emissions from office machines; and (5) explore the potential relationship between energy consumption and pollutant emissions for machines performing equivalent tasks. The study includes desktop computers (CPU units), computer monitors, and three categories of desktop printing devices. The printer categories are: (1) printers and multipurpose devices using color inkjet technology; (2) low- to medium output printers and multipurpose devices employing monochrome or color laser technology; and (3) high-output monochrome and color laser printers. The literature review and screening level experiments in Phase 1 were designed to identify substances of toxicological significance for more detailed study. In addition, these screening level measurements indicate the potential relative importance of different categories of office equipment

  10. Diagnostics of Electric Equipment Windings

    Directory of Open Access Journals (Sweden)

    I. I. Branovitsky

    2007-01-01

    Full Text Available The paper presents methodology and results of the investigations pertaining to study of influence of short-circuited turns on transient electrical processes in electric motor windings. Dependence of their damped speed and value of the difference signal, obtained at reciprocal subtraction of damped oscillation curves in absence and in presence of short-circuited turns, on number of turns in the tested windings. It has been determined that damped oscillation curves, immediately attributed to short-circuited turns, have peak values along temporary axis which are areas of the largest transient process sensitivity to КЗ turns.Methodology for diagnostics of single- and three-phase electric motor windings and also other electric equipment, being realized in DO-1 device, has been developed in the paper. The men­tioned device makes it possible to carry out visual comparison and quantitative analysis of damped oscillation curves in the tested windings with standard ones which are set in the device memory and their difference signals.

  11. Network Resource Awareness and Prediction on Mobile Devices

    NARCIS (Netherlands)

    Peddemors, A.J.H.

    2009-01-01

    In the past several years, personal mobile devices have developed rapidly as versatile computing platforms, capable of installing and running many different applications. Often, these devices are equipped with multiple (wireless) network interfaces supporting internet access through one or more

  12. 18 CFR 1304.401 - Marine sanitation devices.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Marine sanitation... Miscellaneous § 1304.401 Marine sanitation devices. No person operating a commercial boat dock permitted under... equipped with a marine sanitation device (MSD) unless such MSD is in compliance with all applicable...

  13. 30 CFR 57.9330 - Clearance for surface equipment.

    Science.gov (United States)

    2010-07-01

    ... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Loading, Hauling, and Dumping Safety Devices, Provisions, and Procedures for Roadways, Railroads, and Loading and... the farthest projection of moving railroad equipment shall be provided on at least one side of the...

  14. Characteristics of specifications of transportable inverter-type X-ray equipment

    International Nuclear Information System (INIS)

    Yamamoto, Keiichi; Miyazaki, Shigeru

    2003-01-01

    Our X-ray systems study group measured and examined the characteristics of four transportable inverter-type X-ray equipments. X-ray tube voltage and X-ray tube current were measured with the X-ray tube voltage and the X-ray tube current measurement terminals provided with the equipment. X-ray tube voltage, irradiation time, and dose were measured with a non-invasive X-ray tube voltage-measuring device, and X-ray output was measured by fluorescence meter. The items investigated were the reproducibility and linearity of X-ray output, error of pre-set X-ray tube voltage and X-ray tube current, and X-ray tube voltage ripple percentage. The waveforms of X-ray tube voltage, the X-ray tube current, and fluorescence intensity draw were analyzed using the oscilloscope gram and a personal computer. All of the equipment had a preset error of X-ray tube voltage and X-ray tube current that met Japanese Industrial Standards (JIS) standards. The X-ray tube voltage ripple percentage of each equipment conformed to the tendency to decrease when X-ray tube voltage increased. Although the X-ray output reproducibility of system A exceeded the JIS standard, the other systems were within the JIS standard. Equipment A required 40 ms for X-ray tube current to reach the target value, and there was some X-ray output loss because of a trough in X-ray tube current. Owing to the influence of the ripple in X-ray tube current, the strength of the fluorescence waveform rippled in equipments B and C. Waveform analysis could not be done by aliasing of the recording device in equipment D. The maximum X-ray tube current of transportable inverter-type X-ray equipment is as low as 10-20 mA, and the irradiation time of chest X-ray photography exceeds 0.1 sec. However, improvement of the radiophotographic technique is required for patients who cannot move their bodies or halt respiration. It is necessary to make the irradiation time of the equipments shorter for remote medical treatment. (author)

  15. Optimising waste from electric and electronic equipment collection systems: a comparison of approaches in European countries.

    Science.gov (United States)

    Friege, Henning; Oberdörfer, Michael; Günther, Marko

    2015-03-01

    The first European waste from electric and electronic equipment directive obliged the Member States to collect 4 kg of used devices per inhabitant and year. The target of the amended directive focuses on the ratio between the amount of waste from electric and electronic equipment collected and the mass of electric and electronic devices put on the market in the three foregoing years. The minimum collection target is 45% starting in 2016, being increased to 65% in 2019 or alternatively 85% of waste from electric and electronic equipment generated. Being aware of the new target, the question arises how Member States with 'best practice' organise their collection systems and how they enforce the parties in this playing field. Therefore the waste from electric and electronic equipment schemes of Sweden, Denmark, Switzerland, Germany and the Flemish region of Belgium were investigated focusing on the categories IT and telecommunications equipment, consumer equipment like audio systems and discharge lamps containing hazardous substances, e.g. mercury. The systems for waste from electric and electronic equipment collection in these countries vary considerably. Recycling yards turned out to be the backbone of waste from electric and electronic equipment collection in most countries studied. For discharge lamps, take-back by retailers seems to be more important. Sampling points like special containers in shopping centres, lidded waste bins and complementary return of used devices in all retail shops for electric equipment may serve as supplements. High transparency of collection and recycling efforts can encourage ambition among the concerned parties. Though the results from the study cannot be transferred in a simplistic manner, they serve as an indication for best practice methods for waste from electric and electronic equipment collection. © The Author(s) 2015.

  16. Description of the microbial ecology evaluation device, flight equipment, and ground transporter

    Science.gov (United States)

    Chassay, C. E.; Taylor, G. R.

    1973-01-01

    Exposure of test systems in space required the fabrication of specialized hardware termed a Microbial Ecology Evaluation Device that had individual test chambers and a complex optical filter system. The characteristics of this device and the manner in which it was deployed in space are described.

  17. Equipment for nuclear medical centers, production capabilities of Rosatom enterprises

    International Nuclear Information System (INIS)

    Gavrish, Yu. N.; Koloskov, S. A.; Smirnov, V. P.; Strokach, A. P.

    2015-01-01

    Analysis of the capabilities of the State Corporation Rosatom enterprises on the development and production of diagnostic and therapeutic equipment for nuclear medicine centers is presented. Prospects of the development of accelerator equipment for the production of a wide range of radioisotope products are shown, and the trends of its development are determined. A comparative analysis of the technical parameters of domestic tomographs and devices for brachytherapy with foreign counterparts is given

  18. Equipment for nuclear medical centers, production capabilities of Rosatom enterprises

    Science.gov (United States)

    Gavrish, Yu. N.; Koloskov, S. A.; Smirnov, V. P.; Strokach, A. P.

    2015-12-01

    Analysis of the capabilities of the State Corporation Rosatom enterprises on the development and production of diagnostic and therapeutic equipment for nuclear medicine centers is presented. Prospects of the development of accelerator equipment for the production of a wide range of radioisotope products are shown, and the trends of its development are determined. A comparative analysis of the technical parameters of domestic tomographs and devices for brachytherapy with foreign counterparts is given.

  19. Application and Design Characteristics of Generalized Training Devices.

    Science.gov (United States)

    Parker, Edward L.

    This program identified applications and developed design characteristics for generalized training devices. The first of three sequential phases reviewed in detail new developments in Naval equipment technology that influence the design of maintenance training devices: solid-state circuitry, modularization, digital technology, standardization,…

  20. On the choice of structures of equipment for preliminary data processing for a data acquisition subsystem of the automation control system for controlling technological parameters of tokamak devices

    International Nuclear Information System (INIS)

    Bondarenko, I.M.; Gerasimov, V.P.; Mozin, I.V.; Repin, S.S.; Skosarev, V.A.

    1982-01-01

    The necessity is substantiated to use a complex approach to constructing measuring channels of data acquisition subsystems in automation control systems for controlling technological processes in tokamak thermonuclear installations including preliminary data processing equipment, incorporated devices and measuring converters, which enables to minimize the whole bulk of equipment units, while attaining the best metrological features of the channels. Some examples are given designing measuring channels for different kind of signals. Special attention is paid to the choice of structures of measuring channels for signals from sensors under high voltage isolated from the ground potential. It is found reasonable to use analog-time data conversion and optoelectronic isolating elements from the viewpoint of simplicity of apparatus, good manufacturing technology and adjusting measuring channels elements

  1. Design and implement of mobile equipment management system based on QRcode

    Science.gov (United States)

    Yu, Runze; Duan, Xiaohui; Jiao, Bingli

    2017-08-01

    A mobile equipment management system based on QRcode is proposed for remote and convenient device management. Unlike conventional systems, the system here makes managers accessible to real-time information with smart phones. Compared with the conventional method, which can only be operated with specific devices, this lightweight and efficient tele management mode is conducive to the asset management in multiple scenarios.

  2. Recommended safety procedures for the selection, installation and use of baggage inspection x-ray equipment

    International Nuclear Information System (INIS)

    1978-05-01

    Good X-ray equipment alone will not preclude unnecessary exposure to x-radiation. The equipment must be installed, maintained and used by adequately trained personnel, with due regard for the inherent hazards of such equipment and an appreciation of the need to observe proper operational procedures. It is the intent of this Code to define equipment specifications and conditions of installation and use for baggage inspection X-ray equipment, such that the hazard to operating personnel and the general public from such devices remains negligibly small. (auth)

  3. Safety requirements and feedback of commonly used material handling equipment

    International Nuclear Information System (INIS)

    Pathak, M.K.

    2009-01-01

    Different types of cranes, hoists, chain pulley blocks are the most commonly used material handling equipment in industry along with attachments like chains, wire rope slings, d-shackles, etc. These equipment are used at work for transferring loads from one place to another and attachments are used for anchoring, fixing or supporting the load. Selection of the correct equipment, identification of the equipment planning of material handling operation, examination/testing of the equipment, education and training of the persons engaged in operation of the material handling equipment can reduce the risks to safety of people in workplace. Different safety systems like boom angle indicator, overload tripping device, limit switches, etc. should be available in the cranes for their safe use. Safety requirement for safe operation of material handling equipment with emphasis on different cranes and attachments particularly wire rope slings and chain slings have been brought out in this paper. An attempt has also been made to bring out common nature of deficiencies observed during regulatory inspection carried out by AERB. (author)

  4. After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret J.; Busch, John F.

    2004-01-22

    This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in

  5. Catalog of physical protection equipment. Book 1: Volume I. Barriers and structural components

    International Nuclear Information System (INIS)

    Haberman, W.

    1977-06-01

    A catalog of commercially available physical protection equipment has been prepared for use by the U.S. Nuclear Regulatory Commission (NRC). Included is information on barrier structures and equipment, interior and exterior intrusion detection sensors, entry (access) control devices, surveillance and alarm assessment equipment, contraband detection sensors, automated response equipment, general purpose displays and general purpose communications, with one volume devoted to each of these eight areas. For each item of equipment the information included consists of performance, physical, cost and supply/logistics data. The entire catalog is contained in three notebooks for ease in its use by licensing and inspection staff at NRC

  6. Catalog of physical protection equipment. Book 3: Volume VII. General purpose display components

    International Nuclear Information System (INIS)

    1977-06-01

    A catalog of commercially available physical protection equipment has been prepared under MITRE contract AT(49-24)-0376 for use by the U. S. Nuclear Regulatory Commission (NRC). Included is information on barrier structures and equipment, interior and exterior intrusion detection sensors, entry (access) control devices, surveillance and alarm assessment equipment, contraband detection sensors, automated response equipment, general purpose displays and general purpose communications, with one volume devoted to each of these eight areas. For each item of equipment the information included consists of performance, physical, cost and supply/logistics data. The entire catalog is contained in three notebooks for ease in its use by licensing and inspection staff at NRC

  7. Shielding of the 9 TW pulse thermonuclear device equipment from electromagnetic noise

    International Nuclear Information System (INIS)

    Zajtsev, V.I.; Kopyrina, R.I.; Kostromin, A.P.; Olejnik, G.M.

    1990-01-01

    A complex of technical solutions providing for reliable noise-immunity of information-measuring systems, is realized at the ANGARA-5 device. The main method of noise elimination consists in the measurement system shielding and careful wiring of various conductors through the shield. The level of noises connected with the device operation does not exceed 30 mV

  8. The tendency of medical electrical equipment - IEC 60601-2-54: Particular requirements for the basic safety and essential performance of x-ray equipment for radiography and radioscopy

    International Nuclear Information System (INIS)

    Roh, Young Hoon; Kim, Jung Min

    2015-01-01

    Medical electrical equipment - Part 1: General requirement for basic safety and essential performance of MFDS was revised as 3th edition and Medical electrical equipment Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment will be expected to be announced as notification. Therefore this technical report was written to introduce provision of the particular requirements, replacement, addition, amendment. The purpose of this particular requirements is to secure requirements for basic safety and essential performance of X-ray equipment for radiography and radioscopy. X-ray high voltage generator, mechanical protective device, protection against radiation is included in this particular requirements. Medical electrical equipment - Part 1, Part 1-2, Part 1-3 is applied to this particular requirements. If the requirements is announced as notification, It is expected to widen understanding for basic safety and essential performance of X-ray equipment for radiography and radioscopy and play a part to internationalize of medical equipment

  9. 30 CFR 77.401 - Stationary grinding machines; protective devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Stationary grinding machines; protective... OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.401 Stationary grinding machines; protective devices. (a) Stationary grinding machines other than special bit grinders shall be equipped with...

  10. Travelling type monitoring and inspection device

    International Nuclear Information System (INIS)

    Ito, Takao; Maruki, Hideaki.

    1994-01-01

    The present invention sufficiently ensures video output images even if lenses of a television camera of a monitoring means are degraded to reduce the quantity of transmission light. That is, a light amount control mechanism capable of controlling the quantity of illumination light irradiated from an illumination device at an output level of a sensor of an inspection device main body. A test chart for measuring a luminance which is an output level of the sensor is disposed. During plant operation, the lenses of the television camera undergo influences of radioactivity and are degraded to reduce the quantity of transmission light on every periodical monitoring and inspection using a travelling type monitoring inspection device. In this case, the test chart disposed near the equipment to be monitored and inspected is caught by the television camera to measure a sensor output luminance. Then, the light amount control mechanism of the illumination device is controlled so as to provide a luminance which has been set at an initial stage of the plant inspection. With such procedures, video data of the objective equipment to be monitored and inspected can be obtained at a constant luminance during inspection. (I.S.)

  11. 77 FR 43535 - Grantee Codes for Certified Radiofrequency Equipment

    Science.gov (United States)

    2012-07-25

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 2 [FCC 12-60] Grantee Codes for Certified Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: This document... authorization program for radiofrequency (RF) devices under part 2 of its rules. This program is one of the...

  12. Infrastructure for Integration of Legacy Electrical Equipment into a Smart-Grid Using Wireless Sensor Networks.

    Science.gov (United States)

    de Araújo, Paulo Régis C; Filho, Raimir Holanda; Rodrigues, Joel J P C; Oliveira, João P C M; Braga, Stephanie A

    2018-04-24

    At present, the standardisation of electrical equipment communications is on the rise. In particular, manufacturers are releasing equipment for the smart grid endowed with communication protocols such as DNP3, IEC 61850, and MODBUS. However, there are legacy equipment operating in the electricity distribution network that cannot communicate using any of these protocols. Thus, we propose an infrastructure to allow the integration of legacy electrical equipment to smart grids by using wireless sensor networks (WSNs). In this infrastructure, each legacy electrical device is connected to a sensor node, and the sink node runs a middleware that enables the integration of this device into a smart grid based on suitable communication protocols. This middleware performs tasks such as the translation of messages between the power substation control centre (PSCC) and electrical equipment in the smart grid. Moreover, the infrastructure satisfies certain requirements for communication between the electrical equipment and the PSCC, such as enhanced security, short response time, and automatic configuration. The paper’s contributions include a solution that enables electrical companies to integrate their legacy equipment into smart-grid networks relying on any of the above mentioned communication protocols. This integration will reduce the costs related to the modernisation of power substations.

  13. Infrastructure for Integration of Legacy Electrical Equipment into a Smart-Grid Using Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Paulo Régis C. de Araújo

    2018-04-01

    Full Text Available At present, the standardisation of electrical equipment communications is on the rise. In particular, manufacturers are releasing equipment for the smart grid endowed with communication protocols such as DNP3, IEC 61850, and MODBUS. However, there are legacy equipment operating in the electricity distribution network that cannot communicate using any of these protocols. Thus, we propose an infrastructure to allow the integration of legacy electrical equipment to smart grids by using wireless sensor networks (WSNs. In this infrastructure, each legacy electrical device is connected to a sensor node, and the sink node runs a middleware that enables the integration of this device into a smart grid based on suitable communication protocols. This middleware performs tasks such as the translation of messages between the power substation control centre (PSCC and electrical equipment in the smart grid. Moreover, the infrastructure satisfies certain requirements for communication between the electrical equipment and the PSCC, such as enhanced security, short response time, and automatic configuration. The paper’s contributions include a solution that enables electrical companies to integrate their legacy equipment into smart-grid networks relying on any of the above mentioned communication protocols. This integration will reduce the costs related to the modernisation of power substations.

  14. Low-level laser therapy equipment needs calibration before clinical use

    Science.gov (United States)

    Machado de Senna, André; Machado-de-sena, Rosa Maria; Facundes, Arseni Lázaro; Barros Nepomuceno, Patrícia; Sávya Florentino, Wanilza; Olegário de Araújo, Ronyere

    2018-04-01

    Many factors can influence the radiant power delivered by the low-level laser therapy (LLLT) equipment, such as its cleaning and condition, as well as the use of plastic films for protecting the laser or even its time of use. Radiant power is an important factor to consider because it affects the amount of energy delivered to the target tissue. The difference between real radiant power (RRP) and nominal radiant power (NRP) may interfere in the expected results, because the delivered energy is different from the desired energy. Purpose: The objective of this study was to compare the NRP with the RRP offered by LLLT devices under clinical conditions of use. Material and Methods: For data collection to this study, 61 LLLT devices used in private and public dental practices in the state of Tocantins, Brazil, were evaluated. Three consecutive power measurements were performed at one-minute intervals and then the average of the measured power was calculated. The RRP was compared to the NRP. Results: The equipment presented NRP from 30 to 500mW while RRP ranged from 17.3 to 107.0mW. Discussion and Conclusion: The mean power measured in clinical conditions of use of the laser equipment was different from the nominal power reported by the manufacturers of the devices (p<0,01). The RRP ranged between 12.92% and 107% of NRP. This fact is worrisome, since one of the most important parameters for the success of the treatment of an injury using LLLT is the energy (power x time) delivered. These findings reinforce the need of calibrating the equipment before each laser application in order to avoid failures in the therapeutic conduct.

  15. Test and Analysis of Metallurgical Converter Equipment

    Directory of Open Access Journals (Sweden)

    Shan Pang

    2013-05-01

    Full Text Available Oxygen top-blow converter is the main equipment in steel making, and its work reliability decides the security and economy of steel production. Therefore, how to design and test analysis of convertor has been an important subject of industry research. Geometric modelling and structure analysis of converter tilting device by using Pro/E program .The design Principle, basic design structure were analyzed in detail. The computer simulation software of metallurgical converter equipment and how to use it were introduced .It developed by VC++ software. The position of barycentre and moment curve in No.3 and No.4 are calculated. The converter acceleration down dip can be resolved by comparing the moment curve and center curve.

  16. Device for two-stage cementing of casing

    Energy Technology Data Exchange (ETDEWEB)

    Kudimov, D A; Goncharevskiy, Ye N; Luneva, L G; Shchelochkov, S N; Shil' nikova, L N; Tereshchenko, V G; Vasiliev, V A; Volkova, V V; Zhdokov, K I

    1981-01-01

    A device is claimed for two-stage cementing of casing. It consists of a body with lateral plugging vents, upper and lower movable sleeves, a check valve with axial channels that's situated in the lower sleeve, and a displacement limiting device for the lower sleeve. To improve the cementing process of the casing by preventing overflow of cementing fluids from the annular space into the first stage casing, the limiter is equipped with a spring rod that is capable of covering the axial channels of the check valve while it's in an operating mode. In addition, the rod in the upper part is equipped with a reinforced area under the axial channels of the check valve.

  17. Underground coal mining - methods, equipment developments and trends

    Energy Technology Data Exchange (ETDEWEB)

    Singhal, R

    1988-12-01

    Underground mines are truly beginning to accept the so-called 'high tech' technology evident in other industries. Automation, remote control and robotics have taken an added significance. Wireless communication, mine-wide equipment health and performance monitoring, and transmission of data from deeper levels to surface is moving towards becoming the norm. There is emphasis on developing and applying continuous mining systems, as well as on modifying cyclical discontinuous methods to continuous systems. Multi-purpose equipment is also being developed. Technology transfer is playing its role - equipment and systems from surface coal mining are being applied to underground mining and vice-versa. At the American Mining Congress Exhibition held in Chicago in April 1988, a variety of equipment for underground mining was displayed including coal face equipment such as shearer loaders, conveyors and powered supports, and equipment for room-and-pillar coal mining. The trend continues to be towards high power machines equipped with a variety of electronics and sensors, safety devices, and alarm systems. Ancillary equipment on display covered a variety of cutting drums, cutting tools, conveying equipment and so on. In room-and-pillar mining, the overall emphasis was on moving away from the cyclical nature of the work. Transportation by shuttle cars must be replaced by continuous transport systems such as conveyors. Experience from Australia has shown that the application of continuous haulage and breaker line supports has permitted a doubling of production from room-and-pillar systems. Production levels of 3,000tpd have already been achieved, and 4,000tpd is considered achievable.

  18. Plant control device

    International Nuclear Information System (INIS)

    Sato, Masuo; Ono, Makoto.

    1995-01-01

    A plant control device comprises an intellectual instrumentation group for measuring a predetermined process amount, an intellectual equipment group operating in accordance with a self-countermeasure, a system information space for outputting system information, a system level monitoring and diagnosing information generalization section for outputting system information, a system level maintenance information generalization section for outputting information concerning maintenance, a plant level information space and a plant level information generalization section. Each of them determines a state of the plant autonomously, and when abnormality is detected, each of the intellectual instrumentation, equipments and systems exchange information with each other, to conduct required operations including operations of intellectual robots, as required. Appropriate countermeasures for gauges, equipments and systems can be conducted autonomously at a place where operators can not access to improve reliability of complicate operations in the working site, as well as improve plant safety and reliability. (N.H.)

  19. Design scheme of automatic feeding equipment of domestic uranium chemical concentrate

    International Nuclear Information System (INIS)

    Hu Jinming; Wang Chao; Peng Jinhui; Zhang Libo

    2014-01-01

    In order to solve problems by artificial feeding mode with low work efficiency, large intensity manual labor and environmental pollution in domestic uranium concentrate purification process, the design scheme of automatic feeding device was set up, including work flow sheet, composition of automatic equipment and operation. By application of automatic feeding equipment, the feeding speed can be greatly increased, labor force can be reduced, and harm to workman health can be decreased. (authors)

  20. Equipment of Thomson scattering measurement on DIVA plasma

    International Nuclear Information System (INIS)

    Yamauchi, Toshihiko; Kumagai, Katsuaki; Funahashi, Akimasa; Matoba, Thoru; Sengoku, Seio

    1980-02-01

    Equipment of Thomson scattering measurement using ruby-laser light is explained. DIVA device was shut down in September 1979; it gave numerous fruitful experimental results during its five years operation. We measured the profiles of electron temperature and density with the Thomson scattering equipment, which played an important role in research of the energy confinement and heating characteristics. In Thomson scattering measurements on DIVA, studies and improvements were made for reduction of stray light, increase of measuring points and data processing. The profile of electron temperature and density were thus measured successful. In this report is given an over-all view of the Thomson scattering equipment together with the above improvements. As two representative examples, the measured results of electron temperature profiles on DIVA plasma under divertor operation and low-q discharge respectively are described. (author)

  1. Transmitting patient and device data via GSM--central management for decentral mobile medical devices.

    Science.gov (United States)

    Bachmor, T; Schöchlin, J; Bolz, A

    2002-01-01

    Equipping medical devices with long range telemetry opens completely new possibilities for emergency response, home care and remote diagnosis. Mobile communications nowadays seem to be a generally accepted part of our modern world, but bridging the gap between new (consumer-) technologies and medical devices still is a challenge today. Providing a telemetry link (GSM) is just the trivial part--ensuring security, reliability and service management are the more critical tasks that need to be addressed. Therefore, a complete system concept consists of an automatic fleet management (e.g. periodic device-initiated service calls) as well as customer relationship management (CRM), including technical service and a trouble-ticket system.

  2. Integrated software system for improving medical equipment management.

    Science.gov (United States)

    Bliznakov, Z; Pappous, G; Bliznakova, K; Pallikarakis, N

    2003-01-01

    The evolution of biomedical technology has led to an extraordinary use of medical devices in health care delivery. During the last decade, clinical engineering departments (CEDs) turned toward computerization and application of specific software systems for medical equipment management in order to improve their services and monitor outcomes. Recently, much emphasis has been given to patient safety. Through its Medical Device Directives, the European Union has required all member nations to use a vigilance system to prevent the reoccurrence of adverse events that could lead to injuries or death of patients or personnel as a result of equipment malfunction or improper use. The World Health Organization also has made this issue a high priority and has prepared a number of actions and recommendations. In the present workplace, a new integrated, Windows-oriented system is proposed, addressing all tasks of CEDs but also offering a global approach to their management needs, including vigilance. The system architecture is based on a star model, consisting of a central core module and peripheral units. Its development has been based on the integration of 3 software modules, each one addressing specific predefined tasks. The main features of this system include equipment acquisition and replacement management, inventory archiving and monitoring, follow up on scheduled maintenance, corrective maintenance, user training, data analysis, and reports. It also incorporates vigilance monitoring and information exchange for adverse events, together with a specific application for quality-control procedures. The system offers clinical engineers the ability to monitor and evaluate the quality and cost-effectiveness of the service provided by means of quality and cost indicators. Particular emphasis has been placed on the use of harmonized standards with regard to medical device nomenclature and classification. The system's practical applications have been demonstrated through a pilot

  3. Home Healthcare Medical Devices: A Checklist

    Science.gov (United States)

    ... not using it. Contact your doctor and home healthcare team often to review your health condition. * Check ... assurance of their safety and effectiveness. A home healthcare medical device is any product or equipment used ...

  4. Hold-down device for nuclear reactor

    International Nuclear Information System (INIS)

    Leclercq, J.; Bonnamour, M.

    1984-01-01

    The present device can be used in nuclear reactors and more particularly in pressurized water reactors consisting of coupled fuel assemblies, certain of which are equipped with non-displaceable elements carried by an unsertable member. The device comprises the unsertable member provided with at least two sets of springs which transmit the load of an upper structure common to the fuel assemblies ajacent that which supports the unsertable member. The device is used to hold-down fuel assemblies which are subjected to the forces of circulating coolant [fr

  5. Department of Thermonuclear Research annual report 1991

    Energy Technology Data Exchange (ETDEWEB)

    Sadowski, M; Pawlowicz, W [eds.

    1992-02-01

    Department of Thermonuclear Research Annual Report 1991 presents a short review of theoretical, experimental, and technological studies carried out within the framework of two research programs: Plasma Physics and Development of Diagnostics Data Acquisition. Theoretical studies of a tokamak edge plasma, validity of inverse Abel transformation for strongly refracting objects, simulation of the pulse generators operation, and a numerical analysis of electron capture in p + H{sup +} collisions, are described. Experimental studies of corpuscular beams and X-rays from different plasma facilities, development of diagnostic techniques and of data acquisition systems, as well as experiments with the generation of cryogenic pellets for plasma research, are shortly summarized. Also presented are technological studies concerning the modernization of the PF- and RPI-type facilities and the application of the IONOTRON-type devices for the modification of semiconductor and metal surfaces. (author). 27 refs, 24 figs.

  6. Department of Thermonuclear Research annual report 1991

    International Nuclear Information System (INIS)

    Sadowski, M.; Pawlowicz, W.

    1992-02-01

    Department of Thermonuclear Research Annual Report 1991 presents a short review of theoretical, experimental, and technological studies carried out within the framework of two research programs: Plasma Physics and Development of Diagnostics Data Acquisition. Theoretical studies of a tokamak edge plasma, validity of inverse Abel transformation for strongly refracting objects, simulation of the pulse generators operation, and a numerical analysis of electron capture in p + H + collisions, are described. Experimental studies of corpuscular beams and X-rays from different plasma facilities, development of diagnostic techniques and of data acquisition systems, as well as experiments with the generation of cryogenic pellets for plasma research, are shortly summarized. Also presented are technological studies concerning the modernization of the PF- and RPI-type facilities and the application of the IONOTRON-type devices for the modification of semiconductor and metal surfaces. (author). 27 refs, 24 figs

  7. APR1400 Fluidic Device Sensitivity Test

    International Nuclear Information System (INIS)

    Choi, Nam Hyun; Chu, In Cheol; Min, Kyong Ho; Song, Chul Hwa

    2005-12-01

    In the safety injection tank at the emergency core cooling system of APR1400, a new safety design feature, passive fluidic device is equipped which includes no active driving system. It is essential to evaluate the new design feature with various experiments. For this reason, three categories of sensitivity tests have been performed in the present study. As the first sensitivity experiment, the effect of the height of the stand pipe was investigated. The second sensitivity test was conducted with removing the insert plate gasket to examine its effect. The effect of the expansion of the control nozzle width was ascertained from the third sensitivity test. The results of each test showed that the passive fluidic device which will be equipped in the SIT tank of APR1400 has great integrity and repeatability

  8. A proposal of nuclear fusion power plant equipped with SMES

    International Nuclear Information System (INIS)

    Natsukawa, Tatsuya; Makamura, Hirokazu; Molinas, Marta; Nomura, Shinichi; Tsuji-Iio, Shunji; Shimada, Ryuichi

    2000-01-01

    When we intend to operate the nuclear fusion power plant (NFPP) under the economically efficient conditions as an independent power plant, it is desirable that the generated electric power should be sent to network according to the power demand. With such strategy being expanded, some energy storage system is available. In this paper, NFPP equipped with the superconducting magnetic energy storage system (SMES) as electric power storage device is proposed. The advantages of NFPP equipped with SMES are discussed and a case study of 500 MW NFPP equipped with 6 GWh SMES is done with estimating its operational value. For SMES coil, the concept of Force Balanced Coil (FBC) is applied and 6 GWh class FBC is briefly designed

  9. Safety code 19: recommended safety procedures for the selection, installation and use of x-ray diffraction equipment

    International Nuclear Information System (INIS)

    1984-01-01

    This document is one of a series of Safety Codes prepared by the Radiation Protection Bureau to set out requirements for the safe use of radiation emitting devices. The equipment and installation guidelines and safety procedures detailed in this Code are primarily for the instruction and guidance of persons employed in Federal Public Service Departments and Agencies, as well as those coming under the jurisdiction of the Canada Labour Code. This Safety Code is also intended to assist other users of X-ray diffraction equipment to select safe equipment and to install and use it so that the radiation hazard to the operator and other persons in its vicinity is negligible. It should be noted that facilities under provincial jurisdiction may be subject to requirements specified under provincial statutes. This Code supersedes Safety Code RPD-SC-7, entitled 'Requirements For Non-Medical X-Ray Equipment, Use and Installation', insofar as X-ray diffraction equipment is concerned, and it is intended to complement X-ray equipment design, construction and performance standards promulgated under the Radiation Emitting Devices Act

  10. Life extension of low and medium voltage equipment

    International Nuclear Information System (INIS)

    Bharteey, B.M.; Hart, T.J.

    1990-01-01

    Nuclear plant life extension is becoming a very important issue with the passing of each day. Within 3 to 10 years after the turn of the century, licenses of a number of nuclear power plants in the United States will expire. For the near future, new construction of nuclear power plants in the United States is expected to be inhibited, if the current economic and regulatory environment continues to persist. This situation, coupled with aging of utility equipment and the high cost of financing new construction is resulting in a growing emphasis on preserving and extending the capability of existing power plants. Until now, the utilities have placed more emphasis on high cost items, but experience shows that extending life of low cost of device/components in items like Motor Control Center Centers and switchgear pays big dividends. According to the current practice, devices of these items are replaced at the end of their assigned qualified life or attended to when there is a problem resulting in an unplanned outage. In this paper based on extensive experience in the field of motor control centers and medium switchgear, the authors proposed a cookbook methodology to determine the extent or absence of degradation and establish trends of the pertinent operational properties of devices of this type of equipment. The test results also provide satisfactory evidence of class 1E nuclear safety-related function

  11. Two Different Maintenance Strategies in the Hospital Environment: Preventive Maintenance for Older Technology Devices and Predictive Maintenance for Newer High-Tech Devices

    OpenAIRE

    Sezdi, Mana

    2016-01-01

    A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older tec...

  12. Physiotherapy devices able to generate ethical dilemmas

    Directory of Open Access Journals (Sweden)

    Roman Nadinne

    2017-01-01

    Full Text Available Physical therapy is a medical specialty where the professionals help restore movement and function when someone is affected by injury, illness or disability. This paper wishes to establish the connection between ethics, physiotherapy and bioengineering. The research method was achieved using academic database searches based on specific keywords. A SWOT analysis of the physiotherapy devices utilization and design was made, for extracting ethical considerations. The main results suggest that physiotherapy devices are able to generate ethical dilemmas, classified in 4 main items: (1 Bioengineering in physical therapy, ethical and clinical standards for manufacturers; (2 Social impact of physical therapy devices and ethical issues; (3 Inter-professional lack of communication and ethical concerns; (4 Bioengineering ethical research and education. As conclusions, for the physical therapy or electrotherapy research equipment development, a multidisciplinary team is needed. The equipment used in rehabilitation must fulfil specific technical and scientific requirements drafted by the professionals.

  13. Development of support system for maintenance and administration of reprocessing plant equipment

    International Nuclear Information System (INIS)

    Iwasaki, Syogo; Taniguchi, Takayuki; Shiraishi, Yoshihiko; Isaka, Kazuo

    1998-01-01

    Each year, maintenance work is carried out for about 10,000 pieces of equipment, including mechanical devices, electric equipment and instruments, at the Tokai Reprocessing Plant. Ninety percent of such maintenance work is preventive maintenance. In order to manage the information about the maintenance work, a computer support system was developed between 1985 and 1992. Twenty-seven thousand pieces of equipment and 180,000 maintenance histories have already been registered in the system. The system has been used for planning inspections and replacement of equipment as well as checking their maintenance histories. Actual usage of the system has shown that some auxiliary functions need to be added. The system will therefore be improved and extended. (author)

  14. Position statement on use of hand-held portable dental X-ray equipment

    International Nuclear Information System (INIS)

    2014-06-01

    The position statement focuses on justification in the medical field, in particular on the use of hand-held portable dental x-ray equipment. It supplements another HERCA position paper, providing a general overview of the use of all hand-held portable X-ray equipment. Key Messages: - HERCA finds that the use of hand-held portable X-ray devices should be discouraged except in special circumstances. - As a general rule, these devices should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed or semi-mobile x-ray unit is impractical, e.g.: - nursing homes, residential care facilities or homes for persons with disabilities; - forensic odontology, - military operations abroad without dental facilities

  15. The history of anaesthetic equipment evaluation in the United Kingdom: lessons for developing future strategy.

    Science.gov (United States)

    Wilkes, A R; Pandit, J J; O'Sullivan, E

    2011-12-01

    Recent guidance published by the Association of Anaesthetists of Great Britain and Ireland encourages the purchase of equipment based on evidence of safety and performance. For many years, evidence of the safety and performance of anaesthetic equipment was published by various government departments and agencies. However, these schemes were gradually eroded over time such that many devices entered the market with little or no clinical evidence of their efficacy. This recently led to the Difficult Airway Society's issuing guidance to its members on how best to select new airway devices; guidance that was based on the available evidence. This article provides a short history of the evaluation of anaesthetic equipment in the United Kingdom. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  16. Improvement of equipment needed for the detection and characterization of nuclear material and radioactive samples at borders

    International Nuclear Information System (INIS)

    Arlt, R.; Kovar, A.; Swoboda, M.; Beck, P.; Duftschmid, K.E.; Lewis, W.

    2001-01-01

    Nuclear radiation measurement instruments and devices for the detection and characterisation of nuclear material and radioactive isotopes at borders play a decisive role in the set of technical measures needed to deal with the problem of illicit trafficking. Therefore the availability of a range of devices with adequate performance at affordable prices is essential. The needed equipment can be classified into the following categories: Detection equipment (border monitors and radiation pagers); Hand held devices for neutron/gamma source search and in-field characterisation of radiation sources by customs inspectors; NDA (non-destructive assay) instruments for in-depth investigation of a seized item by experts either in the field or under laboratory conditions. Instruments and techniques, which use destructive assay methods, are not considered in this paper. The most recent overview on the performance of such instruments is given in the Final Report of ITRAP (Illicit Trafficking Radiation Detection Assessment Program). According to the findings of ITRAP, although in all above mentioned categories equipment is commercially available, deficiencies and shortcomings were identified. In this paper we describe our effort in addressing some of the most essential equipment problems, identified in ITRAP - the sensitivity of border monitors with respect to the detection of nuclear material and the performance and usability of hand held and portable devices needed for in-field characterisation of seized items by customs inspectors

  17. Equipment for biomass. Wood burners; Materiels pour la biomasse, les chaudieres bois

    Energy Technology Data Exchange (ETDEWEB)

    Chieze, B. [SA Compte R., 63 - Arlanc (France)

    1997-12-31

    A review of the French classification of biomass wastes (and more especially wood and wood wastes) concerning classified burning equipment, is presented: special authorization is thus needed for burning residues from wood second transformation processes. Limits for combustion product emission levels are detailed and their impact on wood burning and process equipment is examined: feeder, combustion chamber, exchanger, fume treatment device, residue disposal. Means for reducing pollutant emissions are reviewed

  18. The likely market potential for electricity saving ASD devices

    International Nuclear Information System (INIS)

    Sparow, F.T.; McKenzie, L.

    1993-01-01

    Many utility demand-side management (DSM) programs encourage the adoption of adjustable speed drives (ASD) in the industrial and commercial sectors, since such devices save KW and KWh. The term open-quotes adjustable speed drives close-quote is used to refer to any device which allows the speed of the motor to be adjusted to better match process requirements. Thus, motor input control devices, such as electronic adjustable speed drives for AC motors (i.e., adjustable frequency drives (AFD)), voltage controlled DC motors, and the use of floating pressure setpoint controls, or other devices which better control on/off compressor operation, would be considered ASD devices. Also included would be motor technologies, such as multi-speed windings, etc., which allow the synchronous speed of the motor to be altered. Not included in this definition would be mechanical systems such as gear boxes, friction disks, etc., which maintain motor speed, but alter the drive r.p.m. to the equipment. The importance of the distinction is that ASDs, as defined above, have the potential to substantially reduce KW and KWh consumption if the equipment duty cycle is varying, while mechanical drive r.p.m. varying devices don't

  19. Uranium material removing and recovering device

    International Nuclear Information System (INIS)

    Takita, Shin-ichi.

    1997-01-01

    A uranium material removing and recovering device for use in removing surplus uranium heavy metal (UO 2 ) generated in a uranium handling facility comprises a uranium material removing device and a uranium material recovering device. The uranium material removing device comprises an adsorbing portion filled with a uranium adsorbent, a control portion for controlling the uranium adsorbent of the uranium adsorbing portion by a controlling agent, a uranium adsorbing device connected thereto and a jetting device for jetting the adsorbing liquid to equipments deposited with uranium. The recovering device comprises a recovering apparatus for recovering uranium materials deposited with the adsorbent liquid removed by the jetting device and a recovering tank for storing the recovered uranium materials. The device of the present invention can remove surplus uranium simply and safely, mitigate body's load upon removing and recovering operations, facilitate the processing for the exchange of the adsorbent and reduces the radioactive wastes. (T.M.)

  20. Structure Analysis of the Graphic Simulator for the PRIDE Equipment

    International Nuclear Information System (INIS)

    Kim, Chang Hoi; Kim, Seong Hyun; Park, Byung Suk; Lee, Jong Kwang; Lee, Hyo Jik; Kim, Ki Ho

    2010-12-01

    Simulation technology based on the computer graphics is able to minimize the trial and error and reduce the development cost and period dramatically at the design stage of the pyroprocessing facility construction and the equipment development. For this purpose, the 3D graphic simulation program named HotCell has been developed. HotCell has continuously updated for the functional addition and the bug fix, and now it reaches version third. The Digital mockup of PRIDE is furnished with the MSM(matster-slave manipulator), BDSM(bridge transported dual arm servo manipulator) and Crane in order to remote handling the processing equipment. HotCell program can be interface with the 3D mouse, the haptic device and the joystick for the realistic operation of above device. The posture of MSM can be recorded with the simple keyboard operation in order to reproduce the behavior of the MSM

  1. High level radioactive waste vitrification process equipment component testing

    International Nuclear Information System (INIS)

    Siemens, D.H.; Heath, W.O.; Larson, D.E.; Craig, S.N.; Berger, D.N.; Goles, R.W.

    1985-04-01

    Remote operability and maintainability of vitrification equipment were assessed under shielded-cell conditions. The equipment tested will be applied to immobilize high-level and transuranic liquid waste slurries that resulted from plutonium production for defense weapons. Equipment tested included: a turntable for handling waste canisters under the melter; a removable discharge cone in the melter overflow section; a thermocouple jumper that extends into a shielded cell; remote instrument and electrical connectors; remote, mechanical, and heat transfer aspects of the melter glass overflow section; a reamer to clean out plugged nozzles in the melter top; a closed circuit camera to view the melter interior; and a device to retrieve samples of the glass product. A test was also conducted to evaluate liquid metals for use in a liquid metal sealing system

  2. Designing electronic equipment on the basis of standard mechanical structures using internet re­sour­ces

    Directory of Open Access Journals (Sweden)

    Karlangach A. P.

    2016-12-01

    Full Text Available The author proposes a method to design electronic equipment based on functional-node design method that involves the use of 2D- and 3D- models mechanical structures for electronic equipment as a way to reduce development time and errors when creating design documentation for electronic equipment. At present, most areas of science and technology are computerized, more problems in designing electronic equipment are dealt with using computer-aided design (CAD and Computer-aided manufacturing (CAM to reduce the time required for development and manufacturing of electronic equipment. Development of design documentation also requires a more effective approach, because the less the time for development of the design documentation is, the faster the developed device will go into production. The aim of the study is to develop a method of designing electronic equipment using 2D and 3D models of standard mechanical structures for electronic equipment using Internet resources. Based on the presented methods is an example of designing a device from standard bearing structures. Compared with traditional technology, the method of designing electronic equipment using standard parts has the following advantages: - reduces time and improves quality of development through the use of existing design documentation; - accelerates the implementation and introducing into production processes; - increases unification of design solutions.

  3. 78 FR 48367 - TRICARE Program; Clarification of Benefit Coverage of Durable Equipment and Ordering or...

    Science.gov (United States)

    2013-08-08

    ...., Seeing Eye dogs, hearing/handicapped assistance animals, etc.). AT devices are authorized only under... must not be otherwise covered as a prosthetic, augmentative communication device, or a benefit under... animals (e.g., Seeing Eye dogs, hearing/handicapped assistance animals, etc.) or specialized equipment and...

  4. Process and device for exchanging neutron absorber rods

    International Nuclear Information System (INIS)

    Baero, G.; Kraus, W.; Stindt, W.

    1987-01-01

    The control element repair device contains lifting equipment for inserting the control element in the accommodation device. Due to the case position assigned to each absorber rod of a control element, after removing the carrier with the absorber rods fixed to it, the defective rods can be replaced by new ones. The accommodation device has a support to support the carrier. Turning the control element for the PWR through 180 0 is prevented. (DG) [de

  5. The parameters of X-ray equipment that influence in patient exposure

    International Nuclear Information System (INIS)

    Peixoto, J.E.

    1988-01-01

    The main components of the X-rays equipment and the secondary device for radiodiagnosis examination are showed. The influence of all radiographs parameters in human exposure as tension and current are also analysed. (C.G.C.) [pt

  6. Device for stretching tapes or cables intended for manipulators

    International Nuclear Information System (INIS)

    Baudoin, J.-C.; Oger, Robert.

    1975-01-01

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device [fr

  7. Device for stretching tapes or cables intended for manipulators

    Energy Technology Data Exchange (ETDEWEB)

    Baudoin, J C; Oger, R

    1975-03-06

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device.

  8. Division of Scientific Equipment - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2002-01-01

    Full text: The Scientific Equipment Division consists of the Design Group and the Mechanical Workshop. The activity of the Division includes the following: * designs of devices and equipment for experiments in physics; their mechanical construction and assembly. In particular, these are vacuum chambers and installations for HV and UHV;* maintenance and upgrading of the existing installations and equipment in our Institute; * participation of our engineers and technicians in design works, equipment assembly and maintenance for experiments in foreign laboratories. The Design Group is equipped with PC-computers and AutoCAD graphic software (release 2000 and Mechanical Desktop 4.0) and an A0 plotter, which allow us to make drawings and 2- and 3-dimensional mechanical documentation to the world standards. The Mechanical Workshop offers a wide range of machining and treatment methods with satisfactory tolerances and surface quality. They include: * turning - cylindrical elements of a length up to 2000 mm and a diameter up to 400 mm, and also disc type elements of a diameter up to 600 mm and a length not exceeding 300 mm, * milling - elements of length up to 1000 mm and gear wheels of diameter up to 300 mm, * grinding - flat surfaces of dimensions up to 300 mm x 1000 mm and cylindrical elements of a diameter up to 200 mm and a length up to 800 mm, * drilling - holes of a diameter up to 50 mm, * welding - electrical and gas welding, including TIG vacuum-tight welding, * soft and hard soldering, * mechanical works including precision engineering, * plastics treatment - machining and polishing using diamond milling, modelling, lamination of various shapes and materials, including plexiglas, scintillators and light-guides, * painting - paint spraying with possibility of using furnace-fired drier of internal dimensions of 800 mm x 800 mm x 800 mm. Our workshop is equipped with the CNC milling machine which can be used for machining of work pieces up to 500 kg. The machine

  9. Supraglottic devices as alternative equipment to airway management in state of sudden cardiac arrest

    Directory of Open Access Journals (Sweden)

    Rafał Czyż

    2017-08-01

    All of supraglottic devices are characterized by easiness in applying without experience in use them. Additionally time need to airway management in use of them is many times shorter than with traditional endotracheal intubation. Fundamental defect in these devices is a fact that they don’t provide total safety before aspiration for chime. Current literature shows us that supraglottic airway devices are perfect alternative to endotracheal intubation.

  10. Equipment for linking source stand and film holder carriage

    International Nuclear Information System (INIS)

    Fajt, P.; Zeman, M.

    1987-01-01

    A device is described for precision link-up of a source stand provided with a spring-loaded cam and a film holder carriage provided with an arm with catches. The catches are mechanically connected to a control device firmly connected to the bottom part of the film holder carriage arm. The cam whose extended part is slidably mounted in the cover guide is secured in position with springs fitted from both sides. The control device consists of an electromagnet with armature connected to the control device pull-rod. The pull-rod provides mechanical connection of the catches and the control device. Upon pressing the pushbutton, the catches automatically engage the film holder cariage arm so that the motorized source stand operates without connection to the carriage. This significantly facilitates the operation of the equipment and reduces physical effort of the technician. The most significant advantage is the possibility of immediate change in operation mode. (J.B.). 5 figs

  11. A Study on Performance and Safety Tests of Defibrillator Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2017-12-01

    Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR). The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public) in one of the provinces of Iran according to international and national standards was evaluated. Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  12. 14 CFR 29.1357 - Circuit protective devices.

    Science.gov (United States)

    2010-01-01

    ... faults or serious malfunction of the system or connected equipment. (b) The protective and control devices in the generating system must be designed to de-energize and disconnect faulty power sources and...

  13. 40 CFR 267.34 - When must personnel have access to communication equipment or an alarm system?

    Science.gov (United States)

    2010-07-01

    ... to an internal alarm or emergency communication device, either directly or through visual or voice... communication equipment or an alarm system? 267.34 Section 267.34 Protection of Environment ENVIRONMENTAL... have access to communication equipment or an alarm system? (a) Whenever hazardous waste is being poured...

  14. The Design and Implementation of the Remote Centralized-Monitoring System of Well-Control Equipment Based on RFID Technique

    Directory of Open Access Journals (Sweden)

    Luo Bin

    2017-01-01

    Full Text Available At present, in domestic for the management of well control equipment continue to the traditional way of nameplates identifies and paper-based registration, there are many issues like the separation of data information of device, easy lose, difficult query, confused management and many other problems, which will make the problem device into the well field, and then resulting in well control runaway drilling accident. To solve the above problems, this paper put forward to the integrated remote centralized-monitoring management mode of the well-control equipment. Taking the advantages of IOT technology, adopting the RFID technology, and combining with the remote transmission, this paper designs the remote centralized-monitoring system of well-control equipment based on RFID, which realizes the intelligent management of well-control equipment and meets the actual demand of the well-control equipment safe use and timely scheduling, and it has the ability of field application.

  15. [2011 after-service customer satisfaction survey of monitoring devices in Shanghai area].

    Science.gov (United States)

    Wang, Lijun; Li, Bin; Qian, Jianguo; Cao, Shaoping; He, Dehua; Zheng, Yunxin

    2013-01-01

    In 2011, Shanghai Medical Equipment Management Quality Control Center launched the fifth after-sale service satisfaction survey for medical devices in Shanghai area. There are 8 classes medical devices involving in the survey. This paper demonstrates the investigation results of monitoring devices which are from different manufacturers.

  16. Regulatory Experience of the Embedded Digital Devices for Safety I and C Systems on Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. M.; Lee, H. K.; Park, H. S. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    Conventional I and C(Instrumentation and Control) systems are tend to becoming unavailable and being replaced by smart equipment. These smart equipment is usually called embedded digital devices (EDDs) or industrial digital devices of limited functionality. Usually, some of these devices are found embedded in plant equipment such as sensing instrumentation, motors, pumps, actuators and breakers. They typically have a micro-processor, RAM, communication interface, a power source, etc. The U.S. Nuclear Regulatory Commission (US NRC) is concerning that these EDDs might exist in procured equipment used in safety systems without the devices having been explicitly identified in procurement documentation. This paper addresses the regulatory experiences of KINS of the EDDs for safety I and C systems and the future works for them. In this paper, we showed regulatory experiences of EDDs which used for safety grade equipment. EDDs might exist in safety grade procured equipment without explicit identification. Undetected defects of EDDs might be the potential safety concerns. EDDs should meet certain specific requirements in order to be selected and used in safety I and C system. We have plan to develop technical positions for identification and qualifying them. The technical position will address, but may not be limited to, quality and reliability, CCFs via software errors, EMC, and CGID for EDDs.

  17. Development of Skylab medical equipment and flight preparations

    Science.gov (United States)

    Johnston, R. S.; Stonesifer, J. C.; Hawkins, W. R.

    1975-01-01

    The major medical systems in the Skylab orbital workshop are described. They comprise the food system, the waste management system, operational bioinstrumentation, personal hygiene, gas sampling, an inflight medical support system, and a cardiovascular counterpressure garment. Life sciences experiments carried out aboard Skylab are also reviewed; these include an ergometer and metabolic analyzer, a lower-body negative pressure device, an electrode harness and body temperature probe, a blood pressure cuff, a leg volume measuring band, sleep studies, a body-mass measuring device, a rotating litter chair, a blood sample processor, and small-mass measuring apparatus. All performance requirements were met with the equipment, and no failures were encountered.

  18. Grinding efficiency improvement of hydraulic cylinders parts for mining equipment

    Directory of Open Access Journals (Sweden)

    Korotkov Aleksandr

    2017-01-01

    Full Text Available The aim of the article is to find out ways to improve parts treatment and components of mining equipment on the example of hydraulic cylinders parts, used as pillars for mine roof supports, and other actuator mechanisms. In the course of the research work methods of machine retaining devices design were used, the scientific approaches for the selection of progressive grinding schemes were applied; theoretical and practical experience in the design and production of new constructions of grinding tools was used. As a result of this work it became possible to create a progressive construction of a machine retaining device for grinding of large parts of hydraulic cylinders, to apply an effective scheme of rotary abrasive treatment, to create and implement new design of grinding tools by means of grains with controllable shape and orientation. Implementation of the results obtained in practice will improve the quality and performance of repairing and manufacturing of mining equipment.

  19. Effects of electromagnetic interference on the functional usage of medical equipment by 2G/3G/4G cellular phones: A revie

    Directory of Open Access Journals (Sweden)

    Periyasamy M. Mariappan

    2016-09-01

    Full Text Available There has been an increase in the potential use of wireless devices in healthcare domain for a variety of reasons. The most commonly used device is the cellular phone, which emits strong electromagnetic energy affecting thereby the functionality of the vital medical equipment such as ventilators, ECG monitors, cardiac monitors, and defibrillators. This prompted the healthcare concerns to restrict the use of these phones in the proximity of critical and non-critical care medical equipment. Due to the developments made in the design of medical equipment to comply with the EMC standards, the restriction had been slowly laid off. Still, the researchers are concerned about the electromagnetic interference with medical devices by cellular phones in the healthcare domain and recommend for conducting continuous research to study their interaction with medical equipment. This paper overviews the certain investigations carried out in the recent years to study the electromagnetic interference between medical devices and 2G/3G/4G LTE cellular phones. During the initial development of cellular phones, the 2G cellular phones had caused more interference that affects the function and operation of some medical devices. The possibility of interference from 3G cellular phones with medical devices was considerably lower than the 2G phones, but still exists. Furthermore, almost all of the 4G phones have little to no interference with the medical devices. Currently, with the development of the medical devices industry, the current medical devices are designed to operate safely under any conditions of usage. Finally, a careful analysis would require statistics on the frequency of adverse events across the healthcare system, which apparently do not exist.

  20. Plant monitoring device

    International Nuclear Information System (INIS)

    Moriyama, Kunio.

    1991-01-01

    The monitoring device of the present invention is most suitable to early detection for equipment abnormality, or monitoring of state upon transient conditions such as startup and shutdown of an electric power plant, a large-scaled thermonuclear device and an accelerator plant. That is, in existent moitoring devices, acquired data are stored and the present operation states are monitored in comparison. A plant operation aquisition data reproduction section is disposed to the device. From the past operation conditions stored in the plant operation data aquisition reproducing section, the number of operation cycles that agrees with the present plant operation conditions is sought, to determine the agreed aquired data. Since these aquired data are time sequential data measured based on the standard time determined by the operation sequence, aquired data can be reproduced successively on every sample pitches. With such a constitution, aquired data under the same operation conditions as the present conditions are displayed together with the measured data. Accordingly, accurate monitoring can be conducted from the start-up to the shutdown of the plant. (I.S.)

  1. Difficult airway equipment in departments of emergency medicine in Ireland: results of a national survey.

    LENUS (Irish Health Repository)

    Walsh, K

    2012-02-03

    BACKGROUND AND OBJECTIVE: Adverse effects associated with difficult airway management can be catastrophic and include death, brain injury and myocardial injury. Closed-malpractice claims have shown prolonged and persistent attempts at endotracheal intubation to be the most common situation leading to disastrous respiratory events. To date, there has been no evaluation of the types of difficult airway equipment currently available in Irish departments of emergency medicine. The objective of this survey was to identify the difficult airway equipment available in Irish departments of emergency medicine. METHODS: Departments of emergency medicine in the Republic of Ireland with at least one dedicated Emergency Medicine consultant were surveyed via telephone. RESULTS: All of the departments contacted held at least one alternative device on site for both ventilation and intubation. The most common alternative ventilation device was the laryngeal mask airway (89%). The most common alternative intubating device was the surgical airway device (100%). CONCLUSIONS: Irish departments of emergency medicine compare well with those in the UK and USA, when surveyed concerning difficult airway equipment. However, we believe that this situation could be further improved by training inexperienced healthcare providers in the use of the laryngeal mask airway and intubating laryngeal mask airway, by placing greater emphasis on the ready availability of capnography and by the increased use of portable difficult airway storage units.

  2. Worldwide outdoor round robin study of organic photovoltaic devices and modules

    DEFF Research Database (Denmark)

    Madsen, Morten Vesterager; Gevorgyan, Suren; Pacios, R.

    2014-01-01

    Accurate characterization and reporting of organic photovoltaic (OPV) device performance remains one of the important challenges in the field. The large spread among the efficiencies of devices with the same structure reported by different groups is significantly caused by different procedures......-to-roll coated OPV cells and modules conducted among 46 laboratories worldwide is presented, where the samples and the testing equipment were integrated in a compact suitcase that served both as a sample transportation tool and as a holder and test equipment during testing. In addition, an internet based...

  3. Pediatric interventional radiography equipment: safety considerations

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2006-01-01

    This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment's capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior-anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child's limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation. (orig.)

  4. Temperature measuring device

    International Nuclear Information System (INIS)

    Brixy, H.

    1977-01-01

    The temperature measuring device is equipped with an electric resistor installed within a metal shroud tube so as to be insulated from it, the noise voltage of which resistor is fed to a measuring unit. The measuring junctions of one or two thermocouples are connected with the electric resistor and the legs of one or both thermocouples can be connected to the measuring unit by means of a switch. (orig.) [de

  5. Development of nuclear fuel microsphere handling techniques and equipment

    International Nuclear Information System (INIS)

    Mack, J.E.; Suchomel, R.R.; Angelini, P.

    1979-01-01

    Considerable progress has been made in the development of microsphere handling techniques and equipment for nuclear applications. Work at Oak Ridge National Laboratory with microspherical fuel forms dates back to the early sixties with the development of the sol-gel process. Since that time a number of equipment items and systems specifically related to microsphere handling and characterization have been identified and developed for eventual application in a remote recycle facility. These include positive and negative pressure transfer systems, samplers, weighers, a blender-dispenser, and automated devices for particle size distribution and crushing strength analysis. The current status of these and other components and systems is discussed

  6. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  7. Evaluation of E.M.F. exposure from medical electrical equipment

    Energy Technology Data Exchange (ETDEWEB)

    Aniolczyk, H.; Mamrot, P.; Politanski, P. [Nofer Institute of Occupational Medicine, Lodz (Poland)

    2006-07-01

    he medical electric and electronic equipment, including electro surgical devices, short- and microwave diathermy units, and magnetic resonance imaging (MRI) systems, belong to the most hazardous sources of electromagnetic emissions. The electromagnetic emissions can interfere with emissions from other medical equipment located in the same facility (e.g. operation rooms) thus having impact on their work, but more importantly, they can be dangerous to patients, medical personnel operating them and other persons. In the present project, an assessment of E.M.F. intensity was performed for more than 2 000 electro surgical devices (330 khz, 440 khz and 1.76 MHz frequency ranges), 1 200 diathermy units and 45 MRI 0.2 - 1.5 T systems. E.M.F. exposure of medical staff was assessed based on respective national hygienic standards. The actual exposure levels were found to exceed the admissible values in Poland. The recorded E.M.F. intensities were compared with relevant Who and U E recommendations (e.g. I.C.N.I.R.P. guidelines, 1998, Directive 2004/40/E.C.). The findings revealed that for 18% of the devices examined, the E.M.F. was higher than the E.M.F. intensity values recommended by U E. (authors)

  8. Evaluation of E.M.F. exposure from medical electrical equipment

    International Nuclear Information System (INIS)

    Aniolczyk, H.; Mamrot, P.; Politanski, P.

    2006-01-01

    he medical electric and electronic equipment, including electro surgical devices, short- and microwave diathermy units, and magnetic resonance imaging (MRI) systems, belong to the most hazardous sources of electromagnetic emissions. The electromagnetic emissions can interfere with emissions from other medical equipment located in the same facility (e.g. operation rooms) thus having impact on their work, but more importantly, they can be dangerous to patients, medical personnel operating them and other persons. In the present project, an assessment of E.M.F. intensity was performed for more than 2 000 electro surgical devices (330 khz, 440 khz and 1.76 MHz frequency ranges), 1 200 diathermy units and 45 MRI 0.2 - 1.5 T systems. E.M.F. exposure of medical staff was assessed based on respective national hygienic standards. The actual exposure levels were found to exceed the admissible values in Poland. The recorded E.M.F. intensities were compared with relevant Who and U E recommendations (e.g. I.C.N.I.R.P. guidelines, 1998, Directive 2004/40/E.C.). The findings revealed that for 18% of the devices examined, the E.M.F. was higher than the E.M.F. intensity values recommended by U E. (authors)

  9. Expansion of the acceptance program: nitrous oxide scavenging equipment and nitrous oxide trace gas monitoring equipment

    Energy Technology Data Exchange (ETDEWEB)

    1977-10-01

    The Acceptance Program for dental materials and devices and the general guidelines for submission of products have been reported in the Journal (88:615 March 1974). At its April 1977 meeting, the Council included equipment for scavenging and monitoring trace nitrous oxide gas in its Acceptance Program. The Council has established the effective date for classification of products under these two sets of guidelines as one year from the date of publication of this announcement. After that date, classification of a product will be required before promotion or exhibition in Association media.

  10. A Study on Performance and Safety Tests of Defibrillator Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2017-12-01

    Full Text Available Introduction: Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR. Materials and Methods: The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public in one of the provinces of Iran according to international and national standards was evaluated. Results: Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Conclusion: Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  11. Performance test of nutrient control equipment for hydroponic plants

    Science.gov (United States)

    Rahman, Nurhaidar; Kuala, S. I.; Tribowo, R. I.; Anggara, C. E. W.; Susanti, N. D.

    2017-11-01

    Automatic control equipment has been made for the nutrient content in irrigation water for hydroponic plants. Automatic control equipment with CCT53200E conductivity controller to nutrient content in irrigation water for hydroponic plants, can be used to control the amount of TDS of nutrient solution in the range of TDS numbers that can be set according to the range of TDS requirements for the growth of hydroponically cultivated crops. This equipment can minimize the work time of hydroponic crop cultivators. The equipment measurement range is set between 1260 ppm up to 1610 ppm for spinach plants. Caisim plants were included in this experiment along with spinach plants with a spinach plants TDS range. The average of TDS device is 1450 ppm, while manual (conventional) is 1610 ppm. Nutrient solution in TDS controller has pH 5,5 and temperature 29,2 °C, while manual is pH 5,6 and temperature 31,3 °C. Manually treatment to hydroponic plant crop, yields in an average of 39.6 grams/plant, greater than the yield of spinach plants with TDS control equipment, which is in an average of 24.6 grams / plant. The yield of caisim plants by manual treatment is in an average of 32.3 grams/crop, less than caisim crop yields with TDS control equipment, which is in an average of 49.4 grams/plant.

  12. Equipment for detach the fuel elements of the irradiated candu fuel bundle

    International Nuclear Information System (INIS)

    Cojocaru, V.; Dinuta, G.

    2013-01-01

    Monitoring the behaviour of the fuel bundles during their combustion provides useful information for the operation of the nuclear power plant as well as for the fuel manufacturer. Before placing it inside the reactor, the fuel bundle is inspected visually, dimensionally and, during combustion in the reactor, its radioactive behaviour is monitored. The purpose of the presented equipment is to allow the visual external inspection of the damaged fuel bundle in order to identify visible defects and to detach the fuel element by breaking the welded connection between the cap and grid. These devices are operated using the handler devices already existing in the hot cells Post-Irradiation Examination Laboratory (LEPI). This equipment has been used successfully in the LEPI laboratory at SCN Pitesti to inspect the damaged fuel from Cernavoda NPP, in March 2013. (authors)

  13. Establishment of experimental equipments in irradiation technology development building (2)

    International Nuclear Information System (INIS)

    Shibata, Hiroshi; Nakano, Hiroko; Suzuki, Yoshitaka; Ohtsuka, Noriaki; Nishikata, Kaori; Takeuchi, Tomoaki; Hirota, Noriaki; Tsuchiya, Kunihiko

    2018-01-01

    From the viewpoints of utilization improvement of the Japan Materials Testing Reactor (JMTR), the experimental devices have been established for the out-pile tests in the irradiation technology development building. The devices for the irradiation capsule assembly, material tests and inspections were established at first and experimental data were accumulated before the neutron irradiation tests. On the other hand, after the Great East Japan Earthquake, the repairs and earthquake-resistant measures of the existing devices were carried out. New devices and equipments were also established for the R and D program for power plant safety enhancement of the Agency for Natural Resources and Energy, Ministry of Economy, Trade and Industry (METI) and 99 Mo/ 99m Tc production development under the Tsukuba International Strategic Zone. This report describes the outline and basic operation manuals of the devices established from 2011 to 2016 and the management points for the safety works in the irradiation technology development building. (author)

  14. The Enemy Within: The Emerging Threats to Healthcare from Malicious Mobile Devices

    OpenAIRE

    Zawoad, Shams; Hasan, Ragib

    2012-01-01

    With the proliferation of wireless networks, mobile devices and medical devices are increasingly being equipped with wireless interfaces, such as Bluetooth and WiFi to allow easy access to and control of the medical devices. Unfortunately, the very presence and usage of such interfaces also expose the medical devices to novel attacks from malicious parties. The emerging threat from malicious mobile devices is significant and severe, since attackers can steal confidential data from a patient's...

  15. Design and construction of the Portable Industrial X-Ray Equipment

    International Nuclear Information System (INIS)

    Nguyen Phuc; Nguyen Van Si; Le Tien Quan; Trinh Anh Tuan; Nguyen Manh Hung; Trinh Dinh Tuong

    2011-01-01

    The main purposes of the project are the supporting to design and construction of the Portable Industrial X-Ray Equipment; with the accuracy ±2% of Output High Voltage 200 kV and Tube current 5 mA. The Equipment is composed of control unit, X-ray generator, and power cable, connection cable. X-ray generator is assembling construction X-ray tube, H.V transformer together with gas insulation (SF6) are sealed up in aluminum bucked cabinet, fan and heat-sink are mounted in the end of X-ray generator as cooling, SF6 is a gas electrical performance to H.V. Alarm lamp is used to warn, flashing, show generating X-ray. Control unit is box construction. Four printed circuit boards (PCB) and electronic device are mounted in it. All operating buttons switches and displays are equipped on the panel. We have completed to design and construct the Portable Industrial X-Ray Equipment; and have tested the electronic parameters of all test points and the main parameters of equipment (the accuracy ±2% of Output High Voltage 200 kV and Tube current 5 mA). We also have successful used the Portable Industrial X-Ray Equipment to evaluate the welds in industry. (author)

  16. Application range of micro focus radiographic devices associated to image processors

    International Nuclear Information System (INIS)

    Cappabianca, C.; Ferriani, S.; Verre, F.

    1987-01-01

    X-ray devices having a focus area less than 100 μ are called micro focus X-ray equipment. Here the range of application and the characteristics of these devices including the possibility of employing the coupling with real time image enhancement computers are defined

  17. Internal inspection devices

    International Nuclear Information System (INIS)

    1982-01-01

    In order to evaluate the possibilities and limits of using specific endoscopes, the design and performance of rigid and flexible endoscopes are studied. The results show on the one hand the physical conditions setting a limit to the applicability of a certain device, and on the other indicate possible ways of improving and modifying given devices so as to adapt them to the special requirements of current testing standards. Based on theoretical and practical experience, proposals for improvements are made. For rigid endoscopes, e.g., additional equipment has been developed and is described in detail, allowing hitherto existing problems to be solved, thus enlarging the range of employment and enhancing and improving the information to be gained by testing using endoscopes. (orig./RW) [de

  18. Photodetection, photon event localization and position tomography device comprising a gammagraphy camera equipped wit such devices

    International Nuclear Information System (INIS)

    Jatteau, M.R.

    1984-01-01

    This device of photodetection and photon event (and noticeably scintillations) localization comprises at least a photomultiplier tube with unique photomultiplying structure and in front of this tube, a net of juxtaposed conduction metal wires excited by voltage pulses. This net comprises only 2n metallic wires to assure the localization of 2sup(2n) possible positions, and that is one of its characteristics [fr

  19. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  20. An investigation of hydrogen storage methods for fuel cell operation with man-portable equipment

    Energy Technology Data Exchange (ETDEWEB)

    Browning, D [Defence Evaluation and Research Agency, Haslar (United Kingdom); Jones, P [Defence Evaluation and Research Agency, Haslar (United Kingdom); Packer, K [Defence Evaluation and Research Agency, Haslar (United Kingdom)

    1997-03-01

    Air breathing proton exchange membrane fuel cells (PEMFC) are being considered as a power source for man-portable equipment, such as army radios. In addition to the weight and volume of the fuel cell itself, the device producing hydrogen with which to fuel the cell is also of crucial importance. This paper describes a number of hydrogen storage methods and discusses their applicability to man-portable equipment. (orig.)

  1. Out-of-hospital noninvasive ventilation: epidemiology, technology and equipment

    Directory of Open Access Journals (Sweden)

    John Scott Baird

    2012-04-01

    Full Text Available Noninvasive ventilation has been utilized successfully in the pre- and out-of-hospital settings for a variety of disorders, including respiratory distress syndrome in neonates, neurologic and pulmonary diseases in infants and children, and heart failure as well as chronic obstructive pulmonary disease in adults. A variety of interfaces as well as mechanical positive pressure devices have been used: simple continuous positive airway pressure devices are available which do not require sophisticated equipment, while a broad spectrum of ventilators have been used to provide bilevel positive airway pressure. Extensive training of transport teams may be important, particularly when utilizing bilevel positive airway pressure in infants and children.

  2. Manufacture research of the test equipment to measure the dose rate in high radiation medium

    International Nuclear Information System (INIS)

    Phan Luong Tuan; Nguyen Van Sy; Nguyen Xuan Vinh; Dang Quang Bao; Nguyen Thanh Hung; Pham Minh Duc; Nguyen Xuan Truong

    2017-01-01

    Photodiode BPW34 is operated as a low voltage counter tubes. When the radiation rays go into the BPW34,they will create a pairs of electron and hole. If setting the reverse bias in to the BPW34, a pulse is achieved and it can be amplified and processed. The STM32 is the microcontroller family which is developed base on ARM processors. The STM32 incorporated many new features such as ADC, I2C, etc. With the connectional ability to other devices, the STM32 is proving its advantages in the development of equipment.The application of irradiation technology in the economy-society increases widespread as food irradiation, mutant irradiation, etc. Until now the calculation the high dose rate at Hanoi Irradiation Center is identified by the Fricke, ECB dosimeters. The dosimeters must be destroyed in order to serve for dose rate determination. Manufacture research the equipment for dose rate calculation support to determine dose rate directly through the equipment’s signal and this equipment can be used multiple. This equipment can be connected to other devices to control the irradiation process better via signals. (author)

  3. Basic concepts and issues: a primer on distribution and sales representative agreements in the medical device and durable medical equipment industries.

    Science.gov (United States)

    Burow, Heiko E; Kolls, Raymond C

    2006-01-01

    Counsel for a manufacturer of medical devices or durable medical equipment must have working knowledge of various legal disciplines to draft contracts with intermediaries (sales representatives and distributors) for the marketing and sale of the manufacturer's products. If the manufacturer wishes to sell its products abroad, counsel must become familiar with the laws and business practices of the target country, and methods of gaining access to the foreign market. This Article gives readers an overview of the applicable legal principles, under U.S. and foreign laws, in the areas of agency, contracts, healthcare regulation, consumer protection, intellectual property protection, and dealer protection. To aid counsel in drafting intermediary agreements, specific contractual terms and issues are explored in depth, including: appointment clauses, performance provisions, provisions concerning pricing and payment, protective clauses (shielding the manufacturer from liability), term and termination provisions, independent contractor clauses, export control clauses, recordkeeping and audit provisions, choice of law clauses, and dispute resolution clauses.

  4. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water spray devices; capacity; water supply... Water spray devices; capacity; water supply; minimum requirements. (a) Where water spray devices are... square foot over the top surface area of the equipment and the supply of water shall be adequate to...

  5. Methods of making microfluidic devices

    KAUST Repository

    Buttner, Ulrich

    2017-06-01

    Microfluidics has advanced in terms of designs and structures, however, fabrication methods are either time consuming or expensive to produce, in terms of the facilities and equipment needed. A fast and economically viable method is provided to allow, for example, research groups to have access to microfluidic fabrication. Unlike most fabrication methods, a method is provided to fabricate a microfluidic device in one step. In an embodiment, a resolution of 50 micrometers was achieved by using maskless high-resolution digital light projection (MDLP). Bonding and channel fabrication of complex or simple structures can be rapidly incorporated to fabricate the microfluidic devices.

  6. 76 FR 12733 - Shenzhen Tangreat Technology Co., Ltd., Grantee of Equipment Authorization FCC ID No. XRLTG-VIPJAMM

    Science.gov (United States)

    2011-03-08

    ... submitted therewith; the manufacture and marketing of equipment that does not conform to the pertinent..., 2011. II. Background 2. In response to complaints regarding the marketing of a radio frequency device... than those associated with a digital device.\\27\\ Contrary to this evidence, however, the test report...

  7. Traveling wire electrode increases productivity of Electrical Discharge Machining /EDM/ equipment

    Science.gov (United States)

    Kotora, J., Jr.; Smith, S. V.

    1967-01-01

    Traveling wire electrode on electrical discharge machining /EDM/ equipment reduces the time requirements for precision cutting. This device enables cutting with a minimum of lost material and without inducing stress beyond that inherent in the material. The use of wire increases accuracy and enables tighter tolerances to be maintained.

  8. 40 CFR 63.489 - Batch front-end process vents-monitoring equipment.

    Science.gov (United States)

    2010-07-01

    ... heater of less than 44 megawatts design heat input capacity is used, a temperature monitoring device in... operator may determine gas stream flow using the design blower capacity, with appropriate adjustments for... are required, each equipped with a continuous recorder. (6) Where a condenser is used, a condenser...

  9. An Interference Mitigation Scheme of Device-to-Device Communications for Sensor Networks Underlying LTE-A.

    Science.gov (United States)

    Kim, Jeehyeong; Karim, Nzabanita Abdoul; Cho, Sunghyun

    2017-05-10

    Device-to-Device (D2D) communication technology has become a key factor in wireless sensor networks to form autonomous communication links among sensor nodes. Many research results for D2D have been presented to resolve different technical issues of D2D. Nevertheless, the previous works have not resolved the shortage of data rate and limited coverage of wireless sensor networks. Due to bandwidth shortages and limited communication coverage, 3rd Generation Partnership Project (3GPP) has introduced a new Device-to-Device (D2D) communication technique underlying cellular networks, which can improve spectral efficiencies by enabling the direct communication of devices in proximity without passing through enhanced-NodeB (eNB). However, to enable D2D communication in a cellular network presents a challenge with regard to radio resource management since D2D links reuse the uplink radio resources of cellular users and it can cause interference to the receiving channels of D2D user equipment (DUE). In this paper, a hybrid mechanism is proposed that uses Fractional Frequency Reuse (FFR) and Almost Blank Sub-frame (ABS) schemes to handle inter-cell interference caused by cellular user equipments (CUEs) to D2D receivers (DUE-Rxs), reusing the same resources at the cell edge area. In our case, DUE-Rxs are considered as victim nodes and CUEs as aggressor nodes, since our primary target is to minimize inter-cell interference in order to increase the signal to interference and noise ratio (SINR) of the target DUE-Rx at the cell edge area. The numerical results show that the interference level of the target D2D receiver (DUE-Rx) decreases significantly compared to the conventional FFR at the cell edge. In addition, the system throughput of the proposed scheme can be increased up to 60% compared to the conventional FFR.

  10. Procurement of medical equipment in Sweden

    Directory of Open Access Journals (Sweden)

    Heikki Terio

    2010-02-01

    Full Text Available In many hospitals in Sweden the importance of technology management is already accepted and accepted since the hospital managements have recognised that technology is an integral part of all major policy and planning decisions. Today’s medical devices are technically complex and sometimes a system of interacting devices is required to achieve the desired clinical function. If the hospitals want to use the latest, modern technology, then they need to make substantial investments in both equipment and competence. Complex technology, large investments and need of highly qualii ed personnel to handle the medical devices are factors that indicate a need of well-dei ned procurement process as an essential part of the total health technology management system that should be used in a hospital. In such a procurement process, carefully prepared planning of technology investments can reduce the running costs and costs for maintenance substantially. In addition, a well-dei ned procurement process contributes to increase the patient safety. In Karolinska University Hospital goods and services are purchased for more than 20% of the hospital’s €1.2 billion turnover. It is therefore very important that the procurement is carried out ef ectively.

  11. Plasma Decontamination of Space Equipment for Planetary Protection

    Science.gov (United States)

    Thomas, Hubertus; Barczyk, Simon; Rettberg, Petra; Shimizu, Satoshi; Shimizu, Tetsuji; Klaempfl, Tobias; Morfill, Gregor; Zimmermann, Julia; Weber, Peter

    The search for extraterrestrial life is one of the most challenging science topics for the next decades. Space missions, like ExoMars, plan to land and search for biological remnants on planets and moons in our nearby Solar system. Planetary protection regulations defined by COSPAR prevent that during the mission biological contamination of the bodies occur through the space probes. Therefore decontamination of the probes and more general space equipment is necessary before the launch. The up-to-date accepted decontamination procedure originate from the old NASA Viking missions and use dry heat (T>110°C for 30h) - a technology not well suited for sensitive equipment nowadays. We investigated in a study financed by the German Space Agency* cold atmospheric plasma (CAP) as an alternative for such decontamination. It is well known that CAP can kill bacteria or spores within seconds or minutes, respectively, if the plasma is in direct contact with the treated sample. This procedure might also be quite aggressive to the treated surface materials. Therefore, we developed an afterglow CAP device specially designed for the soft treatment of space equipment. Afterglow plasma produced by a SMD device in air is transported into a “larger” treatment chamber where the samples are positioned. It could be shown that samples of different bacteria and spores, the latter defined by COSPAR as a means to show the effectiveness of the decontamination process, positioned on different materials (steel, Teflon, quartz) could be effectively inactivated. The surface materials were investigated after the plasma treatment to identify etching or deposition problems. The afterglow in the treatment chamber could even overcome obstacles (tubes of different height and diameter) which simulate more complicated structures of the relevant surfaces. Up to now, CAP looks like a quite promising alternative to decontaminate space equipment and need to be studied in greater detail in the near future

  12. Service for maintenance of electronic equipment of the RA reactor, Report for 1977 - Annex IV

    International Nuclear Information System (INIS)

    Milosevic, M.

    1977-01-01

    This report describes the tasks and organizational structure of the Service for maintenance of electronic equipment of the RA reactor. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment related to the experimental devices [sr

  13. Use of individual protection equipment and collective in case of accident during the transport of radioactive product - class 7

    International Nuclear Information System (INIS)

    Pastura, Valeria da F. e S.; Carvalho, Natanael Bruno de

    2013-01-01

    The personal protective equipment (PPE) are devices used by professionals against potential radiological hazards that may threaten the health or safety in the event of an accident or incident during the transport of radioactive material. The collective protection equipment (CPE) devices are used in place of the accident in order to protect people and the environment from risks such as safety signs, among others. This work will be part of the new edition of the NBR 9735 - Set of equipment for emergencies in land transport of dangerous goods - edited by the Brazilian Association of Technical Standards ABNT - National Standardization Forum which CNEN participates in the Study Committee - CB16 namely, dangerous, accounting for Class 7 radioactive materials. The Standard 9735 establishes the minimum set of equipment for emergencies in Inland transport of dangerous goods, consisting of protective equipment to be used by the driver and staff involved (if any) in the transport operations of transport units, equipment for signaling, isolation of the area of occurrence (fault, accident and/or emergency). Thus, we will present a set of individual and collective equipment that must accompany the carriage of Class 7 products to meet the radiological accident situations and also establish a training base for the driver as the use of them. (author)

  14. Loose part monitoring device

    International Nuclear Information System (INIS)

    Nomura, Hiroshi.

    1992-01-01

    The device of the present invention estimates a place where loose parts occur and structural components as the loose parts in a fluid flow channel of a reactor device, to provide information thereof to a plant operator. That is, the device of the present invention comprises (1) a plurality of detectors disposed to each of equipments constituting fluid channels, (2) an abnormal sound sensing device for sensing signals from the detectors, (3) an estimation section for estimating the place where the loose parts occur and the structural components thereof based on the signals sensed by the abnormal sound sensing section, (4) a memory section for storing data of the plant structure necessary for the estimation, and (5) a display section for displaying the result of the estimation. In such a device, the position where the loose parts collide against the plant structural component and the energy thereof are estimated. The dropping path of the loose parts is estimated from the estimation position. Parts to be loose parts in the path are listed up. The parts on the list is selected based on the estimated energy thereby enabling to determine the loose parts. (I.S.)

  15. 47 CFR 2.803 - Marketing of radio frequency devices prior to equipment authorization.

    Science.gov (United States)

    2010-10-01

    ... advised in writing at the time of the offer for sale that the equipment is subject to the FCC rules and... authority of a local FCC licensed service provider. However, the licensee must grant permission to the... party has the product measured to ensure compliance at the end user's location, the product does not...

  16. Unified electronic unit for miniature radioactivity logging equipment

    International Nuclear Information System (INIS)

    Bragin, A.A.; Goldshtejn, L.M.; Fedorov, R.F.; Shikhman, A.S.

    1981-01-01

    Appropriateness and urgency of the unification of components of radioactivity logging equipment used for the investigation of wells at solid mineral deposits is substantiated. A two-channel electronic unit for miniature equipment for radioactivity logging is described and its basic specifications and performance are given. All functional assemblies of the unit are structurally made in the form of printed circuit boards placed in a pan-shaped chassis 28 mm in diameter. The unit's general design provides for the possibility to attach two probes with detection devices to the unit. The unit is used in the two-channel radioactivity logging instrument ''Kura-2'' and in the two-channel radiometer ''RUR-2''. The outer diameter of these instruments is 48 mm and they ensure the investigation of ore and coal wells with a combination radioactivity methods [ru

  17. Characteristics of specifications of transportable inverter-type X-ray equipment

    CERN Document Server

    Yamamoto, K; Asano, H

    2003-01-01

    Our X-ray systems study group measured and examined the characteristics of four transportable inverter-type X-ray equipments. X-ray tube voltage and X-ray tube current were measured with the X-ray tube voltage and the X-ray tube current measurement terminals provided with the equipment. X-ray tube voltage, irradiation time, and dose were measured with a non-invasive X-ray tube voltage-measuring device, and X-ray output was measured by fluorescence meter. The items investigated were the reproducibility and linearity of X-ray output, error of pre-set X-ray tube voltage and X-ray tube current, and X-ray tube voltage ripple percentage. The waveforms of X-ray tube voltage, the X-ray tube current, and fluorescence intensity draw were analyzed using the oscilloscope gram and a personal computer. All of the equipment had a preset error of X-ray tube voltage and X-ray tube current that met Japanese Industrial Standards (JIS) standards. The X-ray tube voltage ripple percentage of each equipment conformed to the tendenc...

  18. Guideline on evaluation and acceptance of commercial grade digital equipment for nuclear safety applications

    International Nuclear Information System (INIS)

    1996-10-01

    Nuclear power plants are increasingly upgrading their instrumentation and control (I ampersand C) systems with commercial digital equipment, which allows them to continue meeting safety and reliability requirements while controlling operating costs. However, the use of commercial software-based devices for safety related applications has raised new issues that impact design, procurement, and licensing activities. This guideline describes a consistent, comprehensive approach for the evaluation and acceptance of commercial digital equipment for nuclear safety systems

  19. Two Different Maintenance Strategies in the Hospital Environment: Preventive Maintenance for Older Technology Devices and Predictive Maintenance for Newer High-Tech Devices.

    Science.gov (United States)

    Sezdi, Mana

    2016-01-01

    A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older technology devices and predictive maintenance for newer high-tech devices. For preventive maintenance development, 589 older technology devices were subjected to performance verification and safety testing (PVST). For predictive maintenance development, the manufacturers' recommendations were used for 134 high-tech devices. These strategies were evaluated in terms of device reliability. This study recommends the use of two different maintenance strategies for old and new devices at hospitals in developing countries. Thus, older technology devices that applied only corrective maintenance will be included in maintenance like high-tech devices.

  20. Experimental benchmark and code validation for airfoils equipped with passive vortex generators

    DEFF Research Database (Denmark)

    Baldacchino, D.; Manolesos, M.; Ferreira, Célia Maria Dias

    2016-01-01

    Experimental results and complimentary computations for airfoils with vortex generators are compared in this paper, as part of an effort within the AVATAR project to develop tools for wind turbine blade control devices. Measurements from two airfoils equipped with passive vortex generators, a 30...

  1. An assistance device to help people with trunk impairment maintain posture.

    Science.gov (United States)

    Ogura, Tomoka; Itami, Taku; Yano, Ken'ichi; Mori, Ichidai; Kameda, Kazuhiro

    2017-07-01

    People with trunk impairment cannot lean forward because of the dysfunction of the trunk resulting from events such as cervical cord injury (CCI). It is therefore difficult for such people to work at a table because they may easily fall from their wheelchair, and it is also hard for them to return to their original position. This limits the activities of daily living (ADLs) of people with trunk impairment. These problems can be solved to some extent with equipment such as a wheelchair belt or a spinal orthosis that can help the person to maintain his or her posture. However, people cannot move freely with this equipment. Furthermore, if this equipment is used for a long time, there is a risk of physical pain and skin issues. In this study, we developed a device that assists the trunk of people with trunk impairment when they lean forward. This device supports people with trunk impairment so that they may take their meals at the table and prevents them from falling over their wheelchair without hindering their daily performance when they are sitting normally. The effectiveness of our proposed device was verified by experiments involving having a meal, operating a wheelchair, and colliding with a curb. Our device can help people with trunk impairment by improving their ADLs and quality of life (QOL).

  2. 46 CFR 28.110 - Life preservers or other personal flotation devices.

    Science.gov (United States)

    2010-10-01

    ... be equipped with at least one immersion suit, exposure suit, or wearable personal flotation device of..., from both the individual's normal work station and berthing area. If there is no location accessible to both the work station and the berthing area, an appropriate device must be stowed in both locations...

  3. MOBILE DEVICES AND EFFECTIVE INFORMATION SECURITY

    Directory of Open Access Journals (Sweden)

    Igor Bernik

    2013-05-01

    Full Text Available Rapidly increasing numbers of sophisticated mobile devices (smart phones, tab computers, etc. all over the world mean that ensuring information security will only become a more pronounced problem for individuals and organizations. It’s important to effectively protect data stored on or accessed by mobile devices, and also during transmission of data between devices and between device and information system. Technological and other trends show, that the cyber threats are also rapidly developing and spreading. It's crucial to educate users about safe usage and to increase their awareness of security issues. Ideally, users should keep-up with technological trends and be well equipped with knowledge otherwise mobile technology will significantly increase security risks. Most important is that we start educating youth so that our next generations of employees will be part of a culture of data and information security awareness.

  4. Prototype of sun projector device

    Science.gov (United States)

    Ihsan; Dermawan, B.

    2016-11-01

    One way to introduce astronomy to public, including students, can be handled by solar observation. The widely held device for this purpose is coelostat and heliostat. Besides using filter attached to a device such as telescope, it is safest to use indirect way for observing the Sun. The main principle of the indirect way is deflecting the sun light and projecting image of the sun on a screen. We design and build a simple and low-cost astronomical device, serving as a supplement to increase public service, especially for solar observation. Without using any digital and intricate supporting equipment, people can watch and relish image of the Sun in comfortable condition, i.e. in a sheltered or shady place. Here we describe a design and features of our prototype of the device, which still, of course, has some limitations. In the future, this prototype can be improved for more efficient and useful applications.

  5. Nuclear fuel powder transfer device

    International Nuclear Information System (INIS)

    Komono, Akira

    1998-01-01

    A pair of parallel rails are laid between a receiving portion to a molding portion of a nuclear fuel powder transfer device. The rails are disposed to the upper portion of a plurality of parallel support columns at the same height. A powder container is disposed while being tilted in the inside of the vessel main body of a transfer device, and rotational shafts equipped with wheels are secured to right and left external walls. A nuclear powder to be mixed, together with additives, is supplied to the powder container of the transfer device. The transfer device engaged with the rails on the receiving side is transferred toward the molding portion. The wheels are rotated along the rails, and the rotational shafts, the vessel main body and the powder container are rotated. The nuclear powder in the tilted powder container disposed is rotated right and left and up and down by the rotation, and the powder is mixed satisfactory when it reaches the molding portion. (I.N.)

  6. Web software for the control and management of radiation protection devices in the Cadarache site

    International Nuclear Information System (INIS)

    Beltritti, F.

    2010-01-01

    This series of slides presents how to use a new software dedicated to the management of the periodical controls that have to be performed on the equipment involved in radiation protection. This software is ready to be dispatched on the CEA site of Cadarache. This software gives information on: the device to be controlled, the controls that have to be performed, the procedures to follow to make the test, the equipment necessary for the test particularly the need for radioactive sources, the maintenance of the device, the previous measurements and in the end the device's conformity. An evaluation of the conformity of all the devices present in a building or an area or of a particular type can be easily obtained. (A.C.)

  7. Criteria development of remotely controlled mobile devices for TMI-2 [Three Mile Island Unit 2

    International Nuclear Information System (INIS)

    Fillnow, R.; Bengel, P.; Giefer, D.

    1988-01-01

    Since 1982, GPU Nuclear Corporation has used a series of remote mobile devices for data collection and cleanup of highly contaminated areas in the Three Mile Island Unit 2 (TMI-2) nuclear facilities. This paper describes these devices and the general criteria established for their design. Until 1984, the remote equipment used at TMI was obtained from industry sources. This included devices called SISI, FRED, and later LOUIE-1. Following 1984, the direction was to obtain custom-made devices to assure a design that would be more appropriate for the TMI-2 environment. Along with this approach came more detailed criteria and a need for a thorough understanding of the task to be accomplished by the devices. The following families of equipment resulted: (1) remote reconnaissance vehicles (RRVs), (2) the LOUIE family, and (3) remote working vehicle (RWV) family

  8. An update on mobile phones interference with medical devices.

    Science.gov (United States)

    Mahmoud Pashazadeh, Ali; Aghajani, Mahdi; Nabipour, Iraj; Assadi, Majid

    2013-10-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems.

  9. An update on mobile phones interference with medical devices

    International Nuclear Information System (INIS)

    Pashazadeh, A. M.; Aghajani, M.; Nabipour, I.; Assadi, M.

    2013-01-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems. (authors)

  10. Present and future of cutting equipment; Setsudan kiki no genjo to tenbo

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, K. [Koike Sanso Kogyo Co. Ltd., Tokyo (Japan)

    1998-04-01

    This paper describes thermal cutting equipment. Thermal cutting equipment is classified into gas, plasma and laser cutting equipment. Based on the level of automation, the gas cutting equipment has been developed in the order of manual, automatic, eye-tracer, and NC cutters. For recent eye-tracer, paper pattern is inputted in a computer and repeatedly traced. For NC cutting equipment, automatic gas flow rate setting device and sensor for tracing nozzle height are installed. Oxygen plasma cutter is used for cutting soft steel materials. Simplified systems with current below 100 A are mainly used. High-speed cutting is conducted by NC control. Problems of life-time of electrode tips, load of workers, cutting performance, and penetration at corners have been solved. For laser cutter, NC control is also adopted. Since there are no short life-time consumables and conditions can be automatically set, the laser cutter has been put into practice as unmanned equipment. Problems of cutting speed and processing speed have been solved. Gas cutting with multi-blowpipes and unmanned operation of laser cutting are most useful for reducing the cost. 2 figs., 3 tabs.

  11. 30 CFR 75.1107-6 - Capacity of fire suppression devices; location and direction of nozzles.

    Science.gov (United States)

    2010-07-01

    ... nozzles of each fire suppression device shall, where practicable, be located so as to take advantage of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Capacity of fire suppression devices; location... Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment...

  12. Flexible Graphene-based Energy Storage Devices for Space Application Project

    Science.gov (United States)

    Calle, Carlos I.

    2014-01-01

    Develop prototype graphene-based reversible energy storage devices that are flexible, thin, lightweight, durable, and that can be easily attached to spacesuits, rovers, landers, and equipment used in space.

  13. Medicare program; replacement of reasonable charge methodology by fee schedules for parenteral and enteral nutrients, equipment, and supplies. Final rule.

    Science.gov (United States)

    2001-08-28

    This final rule implements fee schedules for payment of parenteral and enteral nutrition (PEN) items and services furnished under the prosthetic device benefit, defined in section 1861(s)(8) of the Social Security Act. The authority for establishing these fee schedules is provided by the Balanced Budget Act of 1997, which amended the Social Security Act at section 1842(s). Section 1842(s) of the Social Security Act specifies that statewide or other area wide fee schedules may be implemented for the following items and services still subject to the reasonable charge payment methodology: medical supplies; home dialysis supplies and equipment; therapeutic shoes; parenteral and enteral nutrients, equipment, and supplies; electromyogram devices; salivation devices; blood products; and transfusion medicine. This final rule describes changes made to the proposed fee schedule payment methodology for these items and services and provides that the fee schedules for PEN items and services are effective for all covered items and services furnished on or after January 1, 2002. Fee schedules will not be implemented for electromyogram devices and salivation devices at this time since these items are not covered by Medicare. In addition, fee schedules will not be implemented for medical supplies, home dialysis supplies and equipment, therapeutic shoes, blood products, and transfusion medicine at this time since the data required to establish these fee schedules are inadequate.

  14. 30 CFR 75.1909 - Nonpermissible diesel-powered equipment; design and performance requirements.

    Science.gov (United States)

    2010-07-01

    ... energy, or leakage; (4) Releases only by a manual control that does not operate any other equipment...; and (xi) A water separator and fuel filter(s) must be provided. (4) A sensor to monitor the..., and accelerator pedals, controls which are of automobile orientation; (4) An audible warning device...

  15. The Use of Noise Dampening Mats to Reduce Heavy-Equipment Noise Exposures in Construction

    Directory of Open Access Journals (Sweden)

    Sabah Saleh

    2017-06-01

    Full Text Available The performance of sound barriers was evaluated to determine their technical effectiveness and practicality in reducing noise exposures to operating engineers in construction. Commercially purchased sound dampening mats (SDMats were installed inside three heavy-equipment engine compartments. Sound pressure levels (SPLs were measured before and after installing the SDMats while the equipment was on idle and full-throttle settings where it normally operates. SPLs inside the heavy-equipment operator cabs were significantly reduced by 5.6–7.6 dBA on the full-throttle setting following installation of the SDMats (p<0.01. The evaluated engineering control intervention was simple to install, affordable, and substantially reduced the engine noise reaching the heavy-equipment operator, potentially reducing reliance on hearing-protection devices to protect construction workers from noise exposures.

  16. Site investigation equipment developed by Teollisuuden Voima Oy

    International Nuclear Information System (INIS)

    Oehberg, A.

    1991-02-01

    Teollisuuden Voima Oy (TVO) carries out site investigations in Finland for final disposal of nuclear high level waste during 1987-2000. In order to carry out the investigations some essential equipment have been designed and constructed. The biggest insufficiency among different measuring methods was among water sampling and hydraulic testing. There are some common specifications which all of these equipment has to fulfil. The two most important are that they have to be operatable in deep slim boreholes down to 1000 meters depth with 56 mm in diameter. The main purpose of the Hydraulic Testing Unit is to determine hydraulic conductivity in crystalline rock, where water can flow primarily through fractures. In most commonly used configurations, measurement range is from 10 - 11 to 10 - 5 m/s with constant-head method. Although constant-head method is principally used, almost any known hydraulic method is possible with existing hardware. Most functions are controlled by the computer. The whole system is built into an electrically heated trailer. The system consists of inflatable packers, stainless steel rods, pressure transducers and datalogging devices. The maximum number of monitoring sections is seven. In addition to that as many blind sections as is needed to prevent vertical flow in boreholes can be installed. Water sampling is possible either with a double packer method or in conjunction with the hydraulic head monitoring equipment. The first possibility involves using the laboratory trailer and the second one using a separate pumping unit plus the laboratory trailer in a later phase when sampling is to be conducted. In the laboratory trailer there are all the measuring devices needed to control different chemical parameters (pH, Eh, pS, O 2 , conductivity and temperature) during pumping

  17. Auxiliary equipment cooling circuit in nuclear reactors

    International Nuclear Information System (INIS)

    Yanagisawa, Ko.

    1986-01-01

    Purpose: To prevent the propagation of bacterias that transform NO 2 into NO 3 in auxiliary equipment coolants using corrosion inhibitors of nitrite type in BWR type reactors. Method: In auxiliary equipments coolant systems, water quality is controlled by using purified water as supplement water and nitrite such as Na 2 NO 2 as the corrosion inhibitors. However, in the circumstance where dissolved oxygen is present, bacteria propagate to oxidize NO 2 into NO 3 . Thus, NO 2 at 200 ppm is reduced to 20 ppm. In view of the above, a surge tank supplied from water supplement line is connected in series and a deaeration device is disposed thereto. Since the presence of dissolved oxygen causes the bacteria to propagate it is desired that the dissolved oxygen density in the supplement water is less than 5 ppm. Deaeration and pressure reduction in the surge tank can remove the dissolved oxygen, prevent NO 3 increase and also prevent stress corrosion cracks in the system pipeways. (Horiuchi, T.)

  18. Alternative water injection device to reactor equipment facility

    International Nuclear Information System (INIS)

    Yamashita, Masahiro.

    1995-01-01

    The device of the present invention injects water to the reactor and the reactor container continuously for a long period of time for preventing occurrence of a severe accident in a BWR type reactor and maintaining the integrity of the reactor container even if the accident should occur. Namely, diesel-driven pumps disposed near heat exchangers of a reactor after-heat removing system (RHR) are operated before the reactor is damaged by the after heat to cause reactor melting. A sucking valve disposed to a pump sucking pipeline connecting a secondary pipeline of the RHR heat exchanger and the diesel driving pump is opened. A discharge valve disposed to a pump discharge pipeline connecting a primary pipeline of the RHR heat exchanger and the diesel driving pump is opened. With such procedures, sea water is introduced from a sea water taking port through the top end of the secondary pipeline of the RHR heat exchanger and water is injected into the inside of the pressure vessel or the reactor container by way of the primary pipeline of the RHR heat exchanger. As a result, the reactor core is prevented from melting even upon occurrence of a severe accident. (I.S.)

  19. Potentialities of fluorography in radiographic testing of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Gromov, Yu.V.; Kapustin, V.I.

    1984-01-01

    Results of fluorography of steel 5-250 mm thick with the application of different radiation sources in accordance with existing test requirements and standards for NPP equipment under industrial conditions, are presented. Sensitivity curves of fluorographic and radiographic testing methods using the RUP-150/300-10 X-ray device, LUEh-15-15000 D linear accelerator flaw detectors with 192 Yr, 60 Co, 137 Cs sources, are given. The radiation energy range is 24O keV-8 MeV. It is shown that fluorographic method meets the requirements of sensitivity and is recommended to test welded joints 5-220 mm thick in NPP equipment under laboratory and industrial conditions

  20. Automated Quality Assurance of Medical Digital X-Ray Equipment

    International Nuclear Information System (INIS)

    Zelikman, Mikhail; Kruchinin, Sergey

    2013-06-01

    Quality assurance of the x-ray equipment includes a set of various tests among which are installation and periodic exams performed by qualified engineers as well as daily routine tests carried out by the medical staff of the Radiology Department. As a rule, the decision concerning the applicability of the x-ray equipment for using in clinical studies is made on the basis of the routine tests results. The presented method is based on the detector's output signals, Signal-to-Noise Ratio and Modulation Transfer Function evaluation in automated way using the simple test-object's digital image registered with given geometry and x-ray exposure parameters settings. Rectangular 20 mm thick aluminum plate with fixed 1 mm thick well-finished steel edge (for general x-ray radiography/fluoroscopy systems) or 2 mm thick aluminum plate with fixed 1 mm thick aluminum well-finished edge (for digital x-ray mammography systems) can be used as a test equipment. Relevant to the decision concerning the x-ray device operation status are the parameters: deviations from the reference levels of the tube voltage and mAs as well as internal detector's noise variance and detector's gain deviations. Everyday testing procedure includes the following steps. On the first step the roentgenographer places the test-object at the center of the detector's surface, makes an exposure with specified parameters setting and geometry and after this, test results are displayed on the work station monitor or console screen in automatic way. In order to provide an automated regime of the presenting algorithm, the software must be integrated with the program module intended for the x-ray device control. The use of the presented method in clinical practice provides the reliable daily monitoring of the x-ray equipment operation status prior to its utilizing for patient diagnostic process. As a rule, it will take not more than 3-5 minutes for the roentgenographer to complete the routine

  1. Extraglottic airway devices: technology update

    Directory of Open Access Journals (Sweden)

    Sharma B

    2017-08-01

    Full Text Available Bimla Sharma, Chand Sahai, Jayashree Sood Department of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, New Delhi, India Abstract: Extraglottic airway devices (EADs have revolutionized the field of airway management. The invention of the laryngeal mask airway was a game changer, and since then, there have been several innovations to improve the EADs in design, functionality, safety and construction material. These have ranged from changes in the shape of the mask, number of cuffs and material used, like rubber, polyvinylchloride and latex. Phthalates, which were added to the construction material in order to increase device flexibility, were later omitted when this chemical was found to have serious adverse reproductive outcomes. The various designs brought out by numerous companies manufacturing EADs resulted in the addition of several devices to the airway market. These airway devices were put to use, many of them with inadequate or no evidence base regarding their efficacy and safety. To reduce the possibility of compromising the safety of the patient, the Difficult Airway Society (DAS formed the Airway Device Evaluation Project Team (ADEPT to strengthen the evidence base for airway equipment and vet the new extraglottic devices. A preuse careful analysis of the design and structure may help in better understanding of the functionality of a particular device. In the meantime, the search for the ideal EAD continues. Keywords: extraglottic airway devices, laryngeal mask airway, other extraglottic airway devices, safety, technology update

  2. THE PROGRAM-TARGET PLANNING AND MANAGEMENT OF DEVELOPMENT OF MEASURING EQUIPMENT PARK

    Directory of Open Access Journals (Sweden)

    Marichev Pavel Aleksandrovich

    2018-02-01

    Full Text Available Subject: study of the Park of Measuring Equipment (PME that includes hundreds of thousands of standard samples, measuring instruments, control and measuring devices and other measuring mechanisms with different areas of application, levels of reliability, service life, levels of technical perfection and levels of technical condition. Research objectives: 1. Development of a complex of mathematical models to simulate the processes of development of PME, control indicators of PME performance as a whole, purposefully control the stages of life cycle of measuring equipment samples. 2. Development of the method which, with a sufficient degree of validity and objectivity, would solve the tasks of management of procurement and repairs both in preparation of proposals for preliminary long-term plan documents (LTPD and to ensure control over the implementation of adopted plans. Thus, the method being developed should be fairly simple to use, easily adjustable for solving problems of different dimensions, suitable for solving the optimal control problem for PME as a whole, for a part of PME, and also suitable for solving a generalized problem for certain “aggregated objects” such as the Metrology Centers. Materials and methods: the methods of mathematical simulation, methods of comparative analysis, simplex method for solving linear programming problem, methods of program-target planning were used. Results: an approach to the solution of problems of program-target planning based on solving a series of linear programming problems has been developed. The results have been presented of using the approach both for formulation of proposals into the preliminary LTPD and also for introducing revisions (amendments to annual plans, which are implemented in the framework of the state defense order. Conclusions: the described method and algorithms constitute an effective tool for solving practical problems of target-oriented management of PME performance

  3. Device for protecting the containment vessel dome of a nuclear reactor

    International Nuclear Information System (INIS)

    Allain, A.; Filloleau, E.; Mulot, P.

    1976-01-01

    A device is disclosed for protecting the dome of a nuclear reactor containment vessel against the upward displacement of the concrete shield slab of said reactor and the resultant effects of tilting of an equipment unit mounted on the shield slab at the periphery of said slab, wherein said device comprises: (1) means for separating the equipment unit into two sections consisting of an upper section and a lower section, said lower section being rigidly fixed to said shield slab and said means being actuated by the upward displacement of said slab, (2) a system for vertical rectilinear guiding of said upper section within the containment vessel, and (3) rigid mechanical components which provide a coupling between the aforesaid upper and lower sections of the equipment unit and exert on said upper section under the action of the tilting motion of said lower section a thrust which causes the upward displacement of said upper section

  4. Equipment for collecting samples of radioactive solutions; Installation de prelevements d'echantillons de solutions radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-12-03

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described.

  5. 30 CFR 77.506 - Electric equipment and circuits; overload and short-circuit protection.

    Science.gov (United States)

    2010-07-01

    ... short-circuit protection. 77.506 Section 77.506 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... circuits; overload and short-circuit protection. Automatic circuit-breaking devices or fuses of the correct type and capacity shall be installed so as to protect all electric equipment and circuits against short...

  6. Equipment of high sensitivity to detect smuggled radioactive materials transported across the ''east-west'' border

    International Nuclear Information System (INIS)

    Antonovski, A.; Kagan, L.; Stavrov, A.

    1998-01-01

    An equipment specially developed for the customs radiation control is described. Its sensitivity is higher than requirements of western countries. The equipment ensures an alarm when a radioactive source (both shielded or not) is found in the controlled area, localizes and identifies the source detected, and provides the radiation protection of customs personnel. Most of devices have a non-volatile memory where the radiation situation history is stored and then transferred to PC. The equipment may be used by personnel of special services for secret detection of radioactive materials. Some Belarussian and Russian documents specifying measures to prevent an unauthorized transportation of radioactive materials are discussed. (author)

  7. Generation of equipment response spectrum considering equipment-structure interaction

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Yoo, Kwang Hoon

    2005-01-01

    Floor response spectra for dynamic response of subsystem such as equipment, or piping in nuclear power plant are usually generated without considering dynamic interaction between main structure and subsystem. Since the dynamic structural response generally has the narrow-banded shapes, the resulting floor response spectra developed for various locations in the structure usually have high spectral peak amplitudes in the narrow frequency bands corresponding to the natural frequencies of the structural system. The application of such spectra for design of subsystems often leads to excessive design conservatisms, especially when the equipment frequency and structure are at resonance condition. Thus, in order to provide a rational and realistic design input for dynamic analysis and design of equipment, dynamic equipment-structure interaction (ESI) should be considered in developing equipment response spectrum which is particularly important for equipment at the resonance condition. Many analytical methods have been proposed in the past for developing equipment response spectra considering ESI. However, most of these methods have not been adapted to the practical applications because of either the complexities or the lack of rigorousness of the methods. At one hand, mass ratio among the equipment and structure was used as an important parameter to obtain equipment response spectra. Similarly, Tseng has also proposed the analytical method for developing equipment response spectra using mass ratio in the frequency domain. This method is analytically rigorous and can be easily validated. It is based on the dynamic substructuring method as applied to the dynamic soil-structure interaction (SSI) analysis, and can relatively easily be implemented for practical applications without to change the current dynamic analysis and design practice for subsystems. The equipment response spectra derived in this study are also based on Tseng's proposed method

  8. Device for covering a string of pump-compressor pipes

    Energy Technology Data Exchange (ETDEWEB)

    Sharafutdinov, I.G.; Prokopov, O.I.; Rastorgyev, M.A.

    1982-01-01

    The invention refers to oil field equipment, and more specifically to devices for automatic coverage of the flow of gusher oil and gas wells during the development of a fire near the well. A device is described for covering the string of pump-compressor pipes which includes a housing with piston connected to the string of pump-compressor pipes, shoe, seat and assembly for fixing the piston in the upper position with heat-sensitive substance. It is distinguished by the fact that in order to improve reliability of its triggering when a fire develops, the assembly for fixing the piston is equipped with hydraulic cylinders whose rods are connected to the piston, and the heat sensitive substance is placed in the vessels whose cavities are connected to the above-piston cavities of the hydraulic cylinders and are connected by a common collector.

  9. Research on Health State Perception Algorithm of Mining Equipment Based on Frequency Closeness

    Directory of Open Access Journals (Sweden)

    Gang Wang

    2014-06-01

    Full Text Available The health state perception of mining equipment is intended to have an online real- time knowledge and analysis of the running conditions of large mining equipments. Due to its unknown failure mode, a challenge was raised to the traditional fault diagnosis of mining equipments. A health state perception algorithm of mining equipment was introduced in this paper, and through continuous sampling of the machine vibration data, the time-series data set was set up; subsequently, the mode set based on the frequency closeness was constructed by the d neighborhood method combined with the TSDM algorithm, thus the forecast method on the basis of the dual mode set was eventually formed. In the calculation of the frequency closeness, the Goertzel algorithm was introduced to effectively decrease the computation amount. It was indicated through the simulation test on the vibration data of the drum shaft base that the health state of the device could be effectively distinguished. The algorithm has been successfully applied to equipment monitoring in the Huoer Xinhe Coal Mine of Shanxi Coal Imp&Exp. Group Co., Ltd.

  10. 49 CFR 571.108, Nt. - Standard No. 108; Lamps, reflective devices, and associated equipment.

    Science.gov (United States)

    2010-10-01

    ... subparagraph (f) of this paragraph, and after cooling to room ambient temperature, a test specimen shall show....4Except for multifunction school activity buses, each school bus shall be equipped with a system of either: (a) Four red signal lamps designed to conform to SAE Standard J887, School Bus Red Signal Lamps, July...

  11. Regulations No. 59 of 20 February 1978 on X-ray skin therapy equipment up to 50 kV

    International Nuclear Information System (INIS)

    1978-01-01

    These regulations lay down the provisions to be complied with for the protection of medical staff and patients when using X-ray equipment for skin therapy. The operators of such equipment must comply with the technical guidelines contained in the regulations and provision is made for annual inspections to ensure that the devices meet the necessary safety standards. (NEA) [fr

  12. 9 CFR 590.502 - Equipment and utensils; PCB-containing equipment.

    Science.gov (United States)

    2010-01-01

    ... Sanitary Standards and accepted practices currently in effect for such equipment. (c) New or replacement equipment or machinery (including any replacement parts) brought onto the premises of any official plant... equipment and machinery, and any replacement parts for such equipment and machinery. Totally enclosed...

  13. The TI-Nspire CAS: A Happy-Medium Mobile Device for Grades 8-16 Mathematics Classrooms

    Science.gov (United States)

    Zelkowski, Jeremy

    2011-01-01

    This article justifies classifying the TI-Nspire CAS Touchpad as a mobile device for grades 8-16 mathematics classrooms equipped with a Navigator system. The 2010 Horizon Report: K-12 indicates virtually every secondary school aged child has some sort of mobile device. Yet, many school policies ban the use of mobile devices, preventing students…

  14. Remote controlled transport device

    International Nuclear Information System (INIS)

    Nakahira, Masataka; Oka, Kiyoshi; Ito, Akira; Tada, Eisuke; Sato, Masaki

    1998-01-01

    The present invention provides a device for transporting equipments for maintenance and parts between a maintenance port and a facility for maintenance by remote control in a radioactive material handling facility such as a nuclear power plant. Namely, a power supply bus bar is disposed along a transferring path in order to supply power to a transporting means, and is divided into every region having a predetermined length. Each of the power supply bus bar regions is controlled for the power supply by a control device. Accordingly, the transporting means can be moved and driven successively being independent on every power supply bus bar region. Accordingly, a plurality of transporting means can be operated independently in a transferring path without laying around power cables and control signal cables. (I.S.)

  15. Human Powered PiezoelectricBatteries to Supply Power to Wearable Electronic Devices.

    OpenAIRE

    Gonzalez, Jose' Luis; Rubio, Antonio; Moll, Francesc

    2002-01-01

    Consumer electronic equipments are becoming small, portable devices that provide users with a wide range of functionality, from communication to music playing. The battery technology and the power consumption of the device limit the size, weight and autonomous lifetime. One promising alternative to batteries (and fuel cells, that must be refueled as well) is to use the parasitic energy dissipated in the movement of the wearer of the device to power it. We analyze in this work the current stat...

  16. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  17. Prototype equipment status monitor for plant operational configuration management

    International Nuclear Information System (INIS)

    DeVerno, M.; Trask, D.; Groom, S.

    1998-01-01

    CANDU plants, such as the Point Lepreau GS, have tens of thousands of operable devices. The status of each operable device must be immediately available to plan and execute future changes to the plant. Historically, changes to the plant's operational configuration have been controlled using manual and administrative methods where the status of each operable device is maintained on operational flowsheets located in the work control area of the main control room. The operational flowsheets are used to plan and develop Operating Orders (OOs) or Order-to-Operate (OTOs) and the control centre work processes are used to manage their execution. After performing each OO procedure, the operational flowsheets are updated to reflect the new plant configuration. This process can be very time consuming, and due to the manual processes, can lead to the potential for time lags and errors in the recording of the current plant configuration. Through a cooperative research and development program, Canadian CANDU utilities and Atomic Energy of Canada Limited, the design organization, have applied modern information technologies to develop a prototype Equipment Status Monitor (ESM) to address processes and information flow for efficient operational configuration management. The ESM integrates electronic operational flowsheets, equipment databases, engineering and work management systems, and computerized procedures to assess, plan, execute, track, and record changes to the plant's operational configuration. This directly leads to improved change control, more timely and accurate plant status information, fewer errors, and better decision making regarding future changes. These improvements to managing the plant's operational configuration are essential to increasing plant safety, achieving a high plant availability, and maintaining high capability and capacity factors. (author)

  18. Device to test the leak-tightness of a container

    International Nuclear Information System (INIS)

    Mills, A.E.; Davey, P.G.

    1978-01-01

    A device is described by which the sensitivity and exactness leak detectors with flow meters may be increased. For this, the flow meter is equipped with two thermal flow sensers and one heating element acting on the two sensors. (RW) [de

  19. Glow discharging device

    International Nuclear Information System (INIS)

    Maeno, Katsuki; Kawasaki, Kozo; Hiratsuka, Hajime; Kawashima, Shuichi.

    1989-01-01

    In a thermonuclear device, etc. impurities adsorbed to inner walls of a vacuum vessel by glow discharge are released to clean the vacuum vessel for preventing intrusion of the impurities into plasmas. The object of the present invention is to minimize the capacity of a power source equipment for the glow discharge device to the least extent. That is, a stabilization resistance is connected in series between each of a plurality of anodes which are inserted and arranged at the inside of a vacuum vessel as a cathode and a power source respectively. The resistance value R is selected so as to satisfy the relation: R < (Vi - Vm)/Ii, in which Vi: glow discharge starting voltage, Vm: glow discharge keeping voltage, Ii: glow discharge starting current. Accordingly, if a voltage is applied from a power source to a plurality of anodes, scattering of electric discharge between the anodes can be suppressed and the effect of voltage drop during discharge by the stabilization resistance can be eliminated. As a result, it is possible to provide an economically advantageous glow discharge device with the capacity for the power source facility being to the least extent. (K.M.)

  20. Communication equipment radiation resistance ensurance

    International Nuclear Information System (INIS)

    Myrova, L.O.; Chelizhenko, A.Z.

    1983-01-01

    A review of works on radiation resistance of electronic equipment (epsilon epsilon) for 15 years is presented. The effect of ionizing radiation appearing as a result of nuclear explosions in nuclear facilities and in outerspace on epsilon epsilon has been considered. Types of radiation effects in epsilon epsilon, radiation effect on semiconductor devices and integrated circUits, types of epsilon epsilon failures, as well as the procass of radiation-resistant epsilon epsilon designing and selection of its main parameters have been described. The methods of epsilon epsilon flowsheet optimization, application of mathematical simulation and peculiarities of ensurance of epsilon epsilon radiation resistance of communication systems are considered. Peculiarities of designing of radiation-resistant quartz generators, secondary power supply sources and amplifiers are discussed

  1. Equipment for maintenance and repair of 900 MW PWR units in France

    International Nuclear Information System (INIS)

    Blary, F.; Castaing, C.; Haessig, M.

    1984-01-01

    As of March 1984, Electricite de France has been operating twenty-seven 900 MW PWR power units. To cut down unit unavailability and reduce the dosimetric requirements of maintenance staff, a wide range of special devices for inspecting and repairing equipment has been designed; details of 64 operational devices and a further 18 still being developed are given in a maintenance catalogue. This special equipment, together with maintenance and repair procedures, has been devised in collaboration with Framatome, the constructor of the nuclear island. One particular problem resolved was that of replacing the pins of the upper internals (UI) of 21 operational units, preventive measures having been taken at the other units. The strategy adopted consisted, first, in setting up a pin-changing workshop to enable the pins and guide tubes to be replaced separately and, second, in devising and applying wherever possible a method for partially replacing the guide tubes outside the critical path of the outage by means of a mobile pool known as the 'Aquarium'. (author)

  2. Italy-Japan international project-based learning for developing human resources using design of welfare equipment as a subject.

    Science.gov (United States)

    Hanafusa, A; Komeda, T; Ito, K; Zobel, P Beomonte

    2015-08-01

    Project-based learning (PBL) is effective for developing human resources of young students. The design of welfare equipment, such as wheelchairs and gait assistive devices, is taken as the subject in this study because these devices must be fit to their environment, users, and method of use; students must consider the circumstances of each country concerned. The program commenced in 2012 at L'Aquila, Italy, and the Shibaura Institute of Technology, Japan and has been continuing for three years. Students were divided into four groups and discussions were held on how to adapt the equipment to the user and environment. After discussion, they designed and simulated a model of the equipment using CAD. Finally, they presented their designs to each other. Through the program, students had fruitful discussions, exchanged ideas from different cultures, and learned from each other. Furthermore, friendships among the students were nurtured. It is believed that the objective of the program was satisfactorily accomplished.

  3. Fiscal 1999 research report. Development of ultralow- loss power device technology (Survey on next-generation practical power semiconductor devices); 1999 nendo choteisonshitsu denryoku soshi gijutsu kaihatsu seika hokokusho. Jisedai power handotai device jitsuyoka chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This research proposes the clear developmental policy and target for 'Development project of ultralow-loss power device technology' through the research on power electronics or advanced power semiconductor devices as key technology of conversion loss reduction for various power applications and power supply systems. Main research issues are as follows. A bidirectional current switch using P-MOS FETs is promising as an ace of power system interconnection control equipment. IEGT as MOS gate high-power device will be substituted for GTO gradually. SiC devices will play the leading part of low- loss power devices for inverters of power converters, power systems of electric vehicles, Shinkansen and maglev railways, power systems of information and communication systems, and DC power systems. Size and cost reduction of low-noise soft switching as application technology of power devices are possible by using active circuits. Development of high- efficiency low-noise compact inexpensive inverters is an important issue. Countermeasures against various losses of inverters are also described. (NEDO)

  4. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  5. Sensor equipment of the German earth scientific airplane program

    Science.gov (United States)

    Seige, P.

    1975-01-01

    The German airplane program for earth scientific research supports the work of a vast staff of earth scientists from universities and federal agencies. Due to their fields of interest, which are in oceanography, hydrology, geology, ecology, and forestry, five test areas were selected which are spread all over Germany. The sensor package, which was designed in accordance with the requirements of this group of scientists, will be installed in a DO 28 D2 type airplane. The sensor equipment consists of a series of 70-mm cameras having different film/filter combinations, a photogrammetric camera, an infrared radiometer, an 11-channel multispectral line scanner, a LANDSAT-compatible radiometer, and a complex avionic system. Along with the airplane, a truck will be equipped with a set of radiometers and other sensor devices for extensive ground-truth measurement; this also includes a cherry picker.

  6. 40 CFR 264.1033 - Standards: Closed-vent systems and control devices.

    Science.gov (United States)

    2010-07-01

    ... determined by dividing the volumetric flow rate (in units of standard temperature and pressure), as.... The system shall be equipped with at least one pressure gauge or other pressure measurement device...

  7. Young children with cerebral palsy: families self-reported equipment needs and out-of-pocket expenditure.

    Science.gov (United States)

    Bourke-Taylor, H; Cotter, C; Stephan, R

    2014-09-01

    Costs to families raising a child with cerebral palsy and complex needs are direct and indirect. This study investigated the self-reported real-life costs, equipment needs, and associated characteristics of children who had the highest equipment and care needs. The purposive sample (n = 29) were families with a child with cerebral palsy: gross motor function levels 5 (n = 20), level 4 (n = 5), level 3 (n = 4); complex communication needs (n = 21); medical needs (n = 14); hearing impairment (n = 5) and visual impairment (n = 9). Participants completed a specifically designed survey that included the Assistance to Participate Scale. Equipment and technology purchases were recorded in the areas of positioning, mobility, transport, home modifications, communication, splinting and orthoses, self-care, technology, communication devices, medical, adapted toys/leisure items and privately hired babysitters/carers. Descriptive and inferential statistics were used to analyse the data. Families had purchased up to 25 items within the areas described. The highest median number of items were recorded for positioning (15 items), mobility devices (9 items) and adapted toys/leisure items (9 items). Median costs were highest for home modifications (AUD$23000), transport (AUD$15000), splints and orthoses (AUD$3145), paid carers (AUD$3080), equipment for toileting/dressing/bathing (AUD$2900) and technical/medical items ($2380). Children who needed more parental assistance to participate in play and recreation also required significantly more equipment overall for positioning, communication, self-care and toys/leisure. The equipment needs of young children with complex disability are extensive and out-of-pocket expenses and parental time to support participation in play/recreation excessive. Substantial financial support to offset costs are crucial to better support families in this life situation. © 2013 John Wiley & Sons Ltd.

  8. EMI Evaluation on Wireless Computer Devices in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Jae Ki; JI Yeong Hwa; Sung, Chan Ho

    2011-01-01

    Wireless computer devices, for example, mice and keyboards are widely used in various industries. However, I and C (instrumentation and control) equipment in nuclear power plants are very susceptible to the EMI (Electro-magnetic interference) and there are concerns regarding EMI induced transient caused by wireless computer devices which emit electromagnetic waves for communication. In this paper, industrial practices and nuclear related international standards are investigated to verify requirements of wireless devices. In addition, actual measurement and evaluation for the intensity of EMI of some commercially available wireless devices is performed to verify their compatibility in terms of EMI. Finally we suggest an appropriate method of using wireless computer devices in nuclear power plant control rooms for better office circumstances of operators

  9. A walker used as a lifting device.

    Science.gov (United States)

    Glimskär, Bo; Hjalmarson, Jenny; Lundberg, Stefan; Larsson, Tore

    2014-05-01

    To develop assistive technology that would help an older person to arise from a kneeling position to a standing one. Developing a prototype, based on an inclusive design and then testing the prototype to verify the approach. The prototype was subsequently tested by a panel of 20 elderly users. These tests were observed and filmed. Participants' experiences of being lifted with the elevation seat were registered with the VIDAR ergonomic assessment system. None of the 20 participants used a walker at that time. In response to a question of whether, assuming they might have to use a walker in the future, they thought that a walker with an elevating seat would be helpful, 18 said that it would. Two of the participants did not believe that they would ever have to use a walker. A simple assistive technology such as a walker equipped with an elevating seat would in many of these cases simplify matters and reduce the distress of people who fall often. In addition, such a device can allow people who fall often to live in their homes longer. For caregivers dealing frequently with people who fall, this assistive device can contribute to decreasing occupational injuries. Development of a lifting device that can help people raise themselves up entirely on their own, or with minimal assistance, would be a revolutionary step for the individual. Lifting devices in use today requires much more extensive assistance from home helpers or others and due to the risk of injuries it is a great value for the helpers that easy to use devices develops. A walker equipped with an elevating seat could even provide a potential for people to stay in their homes longer.

  10. Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment

    NARCIS (Netherlands)

    Togt, R. van der; Lieshout, E.J. van; Hensbroek, R.; Beinat, E.; Binnekade, J.M.; Bakker, P.J.M.

    2008-01-01

    Context: Health care applications of autoidentification technologies, such as radio frequency identification (RFID), have been proposed to improve patient safety and also the tracking and tracing of medical equipment. However, electromagnetic interference (EMI) by RFID on medical devices has never

  11. 30 CFR 75.1101-16 - Dry powder chemical systems; sensing and fire-suppression devices.

    Science.gov (United States)

    2010-07-01

    ...-contained dry powder chemical system shall be equipped with sensing devices which shall be designed to activate the fire-control system, sound an alarm and stop the conveyor drive motor in the event of a rise... belt drive, each sensor shall be equipped with a standby power source which shall be capable of...

  12. The presence of biofilm forming microorganisms on hydrotherapy equipment and facilities.

    Science.gov (United States)

    Jarząb, Natalia; Walczak, Maciej

    2017-10-01

    Hydrotherapy equipment provides a perfect environment for the formation and growth of microbial biofilms. Biofilms may reduce the microbiological cleanliness of hydrotherapy equipment and harbour opportunistic pathogens and pathogenic bacteria. The aims of this study were to investigate the ability of microorganisms that colonize hydrotherapy equipment to form biofilms, and to assess the influence of temperature and nutrients on the rate of biofilm formation. Surface swab samples were collected from the whirlpool baths, inhalation equipment and submerged surfaces of a brine pool at the spa center in Ciechocinek, Poland. We isolated and identified microorganisms from the swab samples and measured their ability to form biofilms. Biofilm formation was observed at a range of temperatures, in both nutrient-deficient and nutrient-rich environments. We isolated and identified microorganisms which are known to form biofilms on medical devices (e.g. Stenotrophomonas maltophilia). All isolates were classified as opportunistic pathogens, which can cause infections in humans with weakened immunity systems. All isolates showed the ability to form biofilms in the laboratory conditions. The potential for biofilm formation was higher in the presence of added nutrients. In addition, the hydrolytic activity of the biofilm was connected with the presence of nutrients.

  13. Unique aspects of downhill ski injuries part 1: epidemiology and equipment.

    Science.gov (United States)

    Buck, P G; Sophocles, A M; Beckenbauch, R D

    1982-03-01

    Skiing is an exciting sport with a significant potential /or serious injury. This potential for injury can be minimized but never entirely eliminated by modern safety equipment.Upper extremity injuries have become relatively more common as the incidence of lower extremity injuries has decreased. Ankle and foot injuries have become infrequent since the advent of the rigid plastic boot, while the incidence of knee injuries has remained essentially constant.Three major mechanisms of injury to the lower extremity include external rotation and abduction, forward fall, and internal rotation. Each mechanism can produce a distinctive set of injured structures.The "skier at risk" is characterized by a lower level of ability, lighter weight, and extremes of age. Injuries can be minimized by purchasing good quality equipment and maintaining it properly; discarding obsolete equipment; using ski brakes, antifriction devices and pistol grip poles; using multirelease bindings for beginners or intermediates; good physical conditioning; taking ski lessons and coupling this with skiing experience; and skiing in control and using common sense on the slopes.Areas which need the most improvement in equipment design include multi-release bindings suitable for all skiers and children's boots. Copyright 2013, SLACK Incorporated.

  14. Orthopaedic Rehabilitation Device Actuated with Pneumatic Muscles

    Directory of Open Access Journals (Sweden)

    Ioana Petre

    2014-07-01

    Full Text Available Year after year recovery clinics worldwide report significant numbers of lower limb bearing joint disabilities. An effective method for the speedy rehabilitation of patients with such afflictions is Continuous Passive Motion (CPM, drawing upon a range of specific equipment. This paper presents an innovative constructive solution for such orthopaedic rehabilitation equipment, designed to ensure a swift reintegration of patients at as low a cost as possible. The absolute novelty consists in the utilization of the linear pneumatic muscle as actuator of the orthopaedic rehabilitation equipment, thus achieving a light and highly compliant construction that satisfies safety requirements related to man-machine interaction. Pneumatic muscles are bio-inspired actuation systems characterized by a passive variable compliant behaviour. This property, deployed in rehabilitation systems, enables the development of human friendly devices, which are comfortable for the patients, and capable of safe interaction. This paper presents the constructive schematic of the orthopaedic rehabilitation equipment, the structure of the actuation and positioning system, and several of its functional characteristics.

  15. Electron beam irradiating device

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, K

    1969-12-20

    The efficiency of an electron beam irradiating device is heightened by improving the irradiation atmosphere and the method of cooling the irradiation window. An irradiation chamber one side of which incorporates the irradiation windows provided at the lower end of the scanner is surrounded by a suitable cooling system such as a coolant piping network so as to cool the interior of the chamber which is provided with circulating means at each corner to circulate and thus cool an inert gas charged therewithin. The inert gas, chosen from a group of such gases which will not deleteriously react with the irradiating equipment, forms a flowing stream across the irradiation window to effect its cooling and does not contaminate the vacuum exhaust system or oxidize the filament when penetrating the equipment through any holes which the foil at the irradiation window may incur during the irradiating procedure.

  16. Standardization of splash device

    Science.gov (United States)

    Fernández Raga, María; Peters, Piet

    2017-04-01

    The erosion is a complex process that has been studied extensively by numerous researchers, requiring a prolongued time effort and a large economic investment. To be effective, the measurements of erosion should be precise, controlled and replicable, and to assure efectiveness, measurement devices of erosion should be properly designed, constructed, well calibrated and also they should be operated by a trained person (Stroosnijder, 2005). Because researchers try to improve old devices, the equipment is constantly being redesigned, making the measurements not comparable and furthermore, producing a lack of available standarized device. The lack of standardization of erosion equipment is more obvious in the case of the local splash erosion, where the nature of the process makes very difficult to isolate its effects. In this article we compare the results obtained from five of the most common splash erosion devices (selected from more than 16 different currently types), under the same rain conditions, with the objective of facilitate the standardization of the method that will be more easy to build, minimizing the error. A set of six splash devices were setted in well known positions under simulated rain, to measured the differences, among devices and the accuracy of the data recovered after 10 minutes of rainfall simulation under different intensities (from 60 to 130 mm/h). The rainfall simulator of Wageningen was used, using sand as splash erosion source. Differences in the infiltration were also measured, and a calibration of sizes and speeds of the raindrops was done using the photography method (Hamidreza-Sadeghi et al., 2013). The splash devices selected for this study were unbounded splash devices (like the funnel, the cup (Fernandez-Raga et al., 2010) and the splash flume (Jomaa et al., 2010)), and bounded devices that allow the calculation of splash rate, (like the new cup (Scholten et al., 2011) and the Morgan tray). The behaviour of different splash devices

  17. Radioactive gaseous waste processing device

    International Nuclear Information System (INIS)

    Murakami, Kazuo.

    1997-01-01

    In a radioactive gaseous waste processing device, a dehumidifier in which a lot of hollow thread membranes are bundled and assembled is disposed instead of a dehumidifying cooling device and a dehumidifying tower. The dehumidifier comprises a main body, a great number of hollow thread membranes incorporated in the main body, a pair of fixing members for bundling and fixing both ends of the hollow thread membranes, a pair of caps for allowing the fixing members to pass through and fixing them on both ends of the main body, an off gas flowing pipe connected to one of the caps, a gas exhaustion pipe connected to the other end of the cap and a moisture removing pipeline connected to the main body. A flowrate control valve is connected to the moisture removing pipeline, and the other end of the moisture removing pipeline is connected between a main condensator and an air extraction device. Then, cooling and freezing devices using freon are no more necessary, and since the device uses the vacuum of the main condensator as a driving source and does not use dynamic equipments, labors for the maintenance is greatly reduced to improve economical property. The facilities are reduced in the size thereby enabling to use space effectively. (N.H.)

  18. Power levels in office equipment: Measurements of new monitors and personal computers

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Brown, Richard E.; Nordman, Bruce; Webber, Carrie A.; Homan, Gregory H.; Mahajan, Akshay; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Electronic office equipment has proliferated rapidly over the last twenty years and is projected to continue growing in the future. Efforts to reduce the growth in office equipment energy use have focused on power management to reduce power consumption of electronic devices when not being used for their primary purpose. The EPA ENERGY STAR[registered trademark] program has been instrumental in gaining widespread support for power management in office equipment, and accurate information about the energy used by office equipment in all power levels is important to improving program design and evaluation. This paper presents the results of a field study conducted during 2001 to measure the power levels of new monitors and personal computers. We measured off, on, and low-power levels in about 60 units manufactured since July 2000. The paper summarizes power data collected, explores differences within the sample (e.g., between CRT and LCD monitors), and discusses some issues that arise in m etering office equipment. We also present conclusions to help improve the success of future power management programs.Our findings include a trend among monitor manufacturers to provide a single very low low-power level, and the need to standardize methods for measuring monitor on power, to more accurately estimate the annual energy consumption of office equipment, as well as actual and potential energy savings from power management

  19. Reduced Physical Fidelity Training Device Concepts for Army Maintenance Training.

    Science.gov (United States)

    1978-09-01

    rapidly. In addition, the task- orientet ’ nature of self-pacee training is creating a need f~r even more equipment to support this newer method of...substitution for AET devices might be considered, to specify the conceptual form for such RPF devices, and to provide proceduial guidance for the future ...describe the RPF alternatives that can be considered for future development by the Army, and to set forth a procedure for their evaluation. The

  20. French Sizing of Medical Devices is not Fit for Purpose

    International Nuclear Information System (INIS)

    Kibriya, Nabil; Hall, Rebecca; Powell, Steven; How, Thien; McWilliams, Richard G.

    2013-01-01

    PurposeThe purpose of the study is to quantify the variation in the metric equivalent of French size in a range of medical devices, from various manufacturers, used in interventional radiology.MethodsThe labelling of a range of catheters, introducers, drains, balloons, stents, and endografts was examined. Products were chosen to achieve a broad range of French sizes from several manufacturers. To assess manufacturing accuracy, eight devices were selected for measurement using a laser micrometer. The external diameters of three specimens of each device were measured at centimeter intervals along the length of the device to ensure uniformity.ResultsA total of 200 labels of interventional radiology equipment were scrutinized. The results demonstrate a wide variation in the metric equivalent of French sizing. Labelled products can vary in diameter across the product range by up to 0.79 mm.The devices selected for measurement with the non-contact laser micrometer demonstrate acceptable manufacturing consistency. The external diameter differed by 0.05 mm on average.ConclusionsOur results demonstrate wide variation in the interpretation of the French scale by different manufacturers of medical devices. This has the potential to lead to problems using coaxial systems especially when the products are from different manufacturers. It is recommended that standard labelling should be employed by all manufacturers conveying specific details of the equipment. Given the wide variation in the interpretation of the French scale, our opinion is that this scale either needs to be abandoned or be strictly defined and followed

  1. An application to estimate the cyber-risk detection skill of mobile device users

    OpenAIRE

    Schaff, Guillaume; Harpes, Carlo; Martin, Romain; Junger, Marianne; Berntzen, Lasse; Böhm, Stephan

    2013-01-01

    According to experts’ predictions, mobile devices (smartphones, tablet computers) will replace the widespread personal computer by 2017 for personal and work tasks (emergence of BYOD). In parallel, the expert community has observed an increase of cyber-attacks against mobile devices. Mobile device users are increasingly required to develop new skills to manage their equipment correctly. Towards this goal, the 21st Century Skills framework redefines the essential knowledge and skills, which pe...

  2. Device for separating ruthenium ion from spent fuel material

    International Nuclear Information System (INIS)

    Izumida, Tatsuo; Sasahira, Akira; Ozawa, Yoshihiro; Kawamura, Fumio.

    1988-01-01

    Purpose: To separate plutonium ions efficiently and selectively from organic solvent containing tributyl phosphate used in the main step of reprocessing process. Constitution: The device comprises, as the main constituent factor, a liquid-liquid contact device for bringing not water soluble organic solvent into contact with a nitric acid solution of spent fuel substances and a liquid-liquid contact-separation device for bringing an organic solvent solution containing spent fuel substances separated with nitric acid into contact again with nitric acid. Then, a device is disposed between two liquid-liquid contact devices for staying ruthenium ions and organic solvent for a sufficient time. In this way, ruthenium ions in the organic solvent containing butyl phosphate are gradually converted into complex compounds combined with tributyl phosphate thereby enabling to separate ruthenium ions efficiently and remarkably reduce the corrosion of equipments. (Horiuchi, T.)

  3. New approach to equipment quality evaluation method with distinct functions

    Directory of Open Access Journals (Sweden)

    Milisavljević Vladimir M.

    2016-01-01

    Full Text Available The paper presents new approach for improving method for quality evaluation and selection of equipment (devices and machinery by applying distinct functions. Quality evaluation and selection of devices and machinery is a multi-criteria problem which involves the consideration of numerous parameters of various origins. Original selection method with distinct functions is based on technical parameters with arbitrary evaluation of each parameter importance (weighting. Improvement of this method, presented in this paper, addresses the issue of weighting of parameters by using Delphi Method. Finally, two case studies are provided, which included quality evaluation of standard boilers for heating and evaluation of load-haul-dump (LHD machines, to demonstrate applicability of this approach. Analytical Hierarchical Process (AHP is used as a control method.

  4. Does home equipment contribute to socioeconomic gradients in Australian children's physical activity, sedentary time and screen time?

    Science.gov (United States)

    Dumuid, Dot; Olds, Timothy S; Lewis, Lucy K; Maher, Carol

    2016-08-05

    Activity behaviours (physical activity, sedentary time and screen time) have been linked to health outcomes in childhood. Furthermore, socioeconomic disparities have been observed in both children's activity behaviours and health outcomes. Children's physical home environments may play a role in these relationships. This study aimed to examine the associations and interactions between children's physical home environment, socioeconomic status and moderate-to-vigorous physical activity, sedentary time and screen time. Australian children (n = 528) aged 9-11 years from randomly selected schools participated in the cross-sectional International Study of Childhood Obesity, Lifestyle and the Environment. Children's physical home environment (access to equipment), socioeconomic status (household income and parental education) and demographic variables (gender and family structure) were determined by parental questionnaire. Moderate-to-vigorous physical activity and sedentary time were measured objectively by 7-day 24-h accelerometry. Screen time was obtained from child survey. The associations between the physical home environment, socioeconomic status and moderate-to-vigorous physical activity, sedentary time and screen time were examined for 427 children, using analysis of covariance, and linear and logistic regression, with adjustment for gender and family structure. The presence of TVs (p music devices (p = 0.04) was significantly and positively associated with screen time. Ownership of these devices (with the exception of music devices) was inversely related to socioeconomic status (parental education). Children's moderate-to-vigorous intensity physical activity (p = 0.04) and possession of active play equipment (p = 0.04) were both positively associated with socioeconomic status (household income), but were not related to each other (with the exception of bicycle ownership). Children with less electronic devices, particularly in their bedrooms

  5. Progress in ion implantation equipment for semiconductor manufacturing

    International Nuclear Information System (INIS)

    Kawai, Tadashi; Naito, Masao

    1987-01-01

    In the semiconductor device manufacturing industry, ion implantation systems are used to dope semiconductor substrates with impurities that act as donor or acceptor. In an ion implantation system, required impurity ions are generated from an ion source, subjected to mass analysis, accelerated, converged and implanted in semiconductor wafers. High-tension arc tends to cause troubles in these systems, but improvement in design increased the average operation rate of medium-power systems from bout 70 percent to 90 percent during the past 10 years. Freeman type ion sources have replaced most RF ion sources and cold cathode PIG sources, which had been widely used until the early 1970s. Many of the recent ion sources are equipped with a P and As vaporizer to increase the beam intensity. By an increased beam intensity or decreased handling time in combination with an automatic handling system, the throughput has reached 330 wafers per hour for 10 second implantation. The yield has increased due to the development of improved scanning methods, vacuum devices such as cryopump, and processes and apparatus that serve for preventing particles from being contained in micro-devices. Various other improvements have been made to permit efficient production. (Nogami, K.)

  6. 40 CFR 265.1033 - Standards: Closed-vent systems and control devices.

    Science.gov (United States)

    2010-07-01

    ... actual exit velocity of a flare shall be determined by dividing the volumetric flow rate (in units of.... The system shall be equipped with at least one pressure gauge or other pressure measurement device...

  7. Design considerations for medical devices in the home environment.

    Science.gov (United States)

    Kaufman-Rivi, Diana; Collins-Mitchell, Janette; Jetley, Raoul

    2010-01-01

    Patient demographics, economic forces, and technological advancements contribute to the rise in home care services. Advanced medical devices and equipment originally designed for use by trained personnel in hospitals and clinics are increasingly migrating into the home. Unlike the clinical setting, the home is an uncontrolled environment with additional hazards. The compatibility of the device with the recipient's knowledge, abilities, lifestyle, and home environment plays a significant role in their therapy and rehabilitation. The advent of new device technologies such as wireless devices and interoperability of systems lends a new and complex perspective for medical device use in the home that must also be addressed. Adequately assessing and matching the patient and their caregiver with the appropriate device technology while considering the suitability of the home environment for device operation and maintenance is a challenge that relies on good human factors principles. There is a need to address these challenges in the growing home care sector In this article, the authors take a look at some important considerations and design issues for medical devices used in the home care environment.

  8. Radiotherapy equipment for conformal radiotherapy and IMRT in the Czech Republic

    International Nuclear Information System (INIS)

    Horakova, I.; Irena Pavlikova, I.; Novotny, J. ml.

    2005-01-01

    The development of the equipment of radiotherapy departments in the Czech Republic is presented here. The data from the special questionnaire from 14 workplaces with linear accelerators with multi-leaf collimators (MLC) and electronic portal imaging device (EPID) are included. They show not only the equipment specification but also the application methods, the quality control, plans for future etc. In the Czech Republic, a great extension of modem irradiation techniques and accessories occurs at present. Together with it, it is necessary to develop quality assurance of the whole process of dose delivery to the patient. It is also necessary to assure further education and training of hospital staff. Modern radiotherapy techniques demand sufficient amount of all sources including personal sources. (authors)

  9. Acquired image quality in digital industrial radiographic equipments

    International Nuclear Information System (INIS)

    Oliveira, Cristiane de Queiroz; Lopes, Ricardo Tadeu; Oliveira, Davi F.

    2008-01-01

    The computerized radiographic application in the industrial area is a recent event. The imaging plate is the equipment used as imaging receiver during the exposition radiographic technique, which consists of a flexible photostimulable phosphor screen, capable of storing the photons energy of the incident X and γ rays and of a reading unit which uses a laser device to stimulate a visible light. As two types of phosphor screen are manufactured, one for general use (General Plate - GP) and another one for specific using (High Resolution-HR), one of the objectives of this study was to evaluate the spatial resolution capability in both plates using the Kodak equipment. Furthermore, equipment from different makers, Kodak and General Electric Company - GE, were compared. Two phosphor screen HR were used as the main objective of this study. Imaging Quality Indicators - IQI were used to evaluate the spatial resolution of the images in accordance with ASME and DIN standard. The results show that after evaluating the GP and HR Kodak plates, the HR plate was capable of showing a larger resolution of details. However, after evaluating the performance of the HR Kodak plate and GE plate, over the same acquisition condition and with the same size of the laser focal set of 87 μm, the results show a superiority in the GE equipment used for industrial radiographic, mainly for processed images in each specific ambient of digital processing and its performance in meeting satisfactorily the ASME code and the DIN standard. (author)

  10. Application of Devices and Systems Designed for Power Quality Monitoring and Assessment

    Directory of Open Access Journals (Sweden)

    Wiesław Gil

    2014-03-01

    Full Text Available The paper presents the problems associated with increasing demands on the equipment and systems for power quality assessment (PQ, installed at power substations. Difficulties are signaled due to current lack of standards defining the test methodology of measuring devices. The necessary device properties and the structure of a large system operated in real time and designed to assess the PQ are discussed. The usefulness of multi-channel analyzers featuring the identification and registration of transients is pointed out. The desirability of synchrophasor assessment implementation and device integration by standard PN-EN 61850 with other SAS devices is also justified.

  11. Paralympic sports medicine--current evidence in winter sport: considerations in the development of equipment standards for paralympic athletes.

    Science.gov (United States)

    Burkett, Brendan

    2012-01-01

    To highlight and discuss the considerations for the future development of equipment standards for Winter Paralympic sports. Literature searches were performed (in English) during May 2011 using the key words "technology, winter sport, Olympic, and Paralympic" in the computerized databases PubMed, PsycINFO, Science Direct, and Google Scholar. In addition, personal scientific observations were made at several Winter Paralympic Games. The retrieved articles were screened and assessed for relevance to the biological, biomechanical, and sport medicine aspects of equipment. There are 3 key areas in which technology has influenced sports performance in Paralympic winter sports, namely, specialized prostheses, crutch skis or outriggers (in lieu of poles), and sport-specific wheelchairs (such as the sit-ski). From a sport medicine perspective, a crucial factor not considered in the standard laboratory test of mechanical efficiency is the influence of the human-equipment connection, such as the stump-to-prosthesis interface or the required human-to-wheelchair control. This connectivity is critical to the effective operation of the assistive device. When assessing the efficiency of this equipment, the not-so-obvious, holistic, compensatory factors need to be considered. Assistive equipment is fundamental for a person with a disability to participate and compete in winter sport activities. Although there have been improvements in the mechanical function of some assistive devices, the key issue is matching the residual function of the person with the assistive equipment. Equitable access to this technology will also ensure that the fundamental spirit of fair play that underpins the Paralympic Games is maintained.

  12. Leak detecting and identifying device in a reactor container

    International Nuclear Information System (INIS)

    Ito, Toshiichiro; Tomisawa, Teruaki; Yamada, Minoru.

    1987-01-01

    Purpose: To facilitate early detection and position identification for the leakages in a reactor container, shorten the start-up time for the nuclear power plant and reduce the equipment damages due to leakage. Constitution: Sensor signals from image sensors for obtaining infrared radiation image data are converted into image information and sent to a diagnosis device. While on the other hand, process variant signals from a process computer for obtaining plant status data are sent to a status judging device by which the plant status is judged based on the process variants such as water level, pressure and radioactivity in the reactor. The status judging device retrieves the status image aligned with the present plant status sent from the first memory device and transfers reference image information signals to the diagnosis device as the reference. The diagnosis device compares the present images with the reference images and displays the result of the judgement on CRT. (Yoshino, Y.)

  13. Device for making firewood; Laite polttopuun tekoon

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen, E [Haemeen Teraesrakenne Oy, Haemeenlinna (Finland)

    1997-12-31

    By present equipment it is impossible to make firewood with single-stage processing of the trees. Pulpwood and logs are collected from the forests, but energy wood has to be collected separately and processed in a different place. The aim of the project was to develop a device, by which it is possible to make firewood on the felling site using single-stage processing, and packing the firewood directly to large packages ready for delivery or utilization. It is possible to make e.g. either 3 m long pulpwood or small-logs by the device. A farming tractor is used as traction and power supply unit of the device. The method is especially useful in first thinnings. A study and costs analysis were made for the basis of the research in Evo unit of the Haeme Polytechnic Institute of Technology. Logic control of the device was developed in the Haemeenlinna unit of the Haeme Polytechnic. Two prototype devices have been made. The test results have shown that firewood production speed will be multiplied in comparison to the previous devices, and the out-look of firewood is remarkable better. The method has been patented

  14. Device for making firewood; Laite polttopuun tekoon

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen, E. [Haemeen Teraesrakenne Oy, Haemeenlinna (Finland)

    1996-12-31

    By present equipment it is impossible to make firewood with single-stage processing of the trees. Pulpwood and logs are collected from the forests, but energy wood has to be collected separately and processed in a different place. The aim of the project was to develop a device, by which it is possible to make firewood on the felling site using single-stage processing, and packing the firewood directly to large packages ready for delivery or utilization. It is possible to make e.g. either 3 m long pulpwood or small-logs by the device. A farming tractor is used as traction and power supply unit of the device. The method is especially useful in first thinnings. A study and costs analysis were made for the basis of the research in Evo unit of the Haeme Polytechnic Institute of Technology. Logic control of the device was developed in the Haemeenlinna unit of the Haeme Polytechnic. Two prototype devices have been made. The test results have shown that firewood production speed will be multiplied in comparison to the previous devices, and the out-look of firewood is remarkable better. The method has been patented

  15. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  16. Adjustable radiation protection device of the fluoroscope DG 10

    International Nuclear Information System (INIS)

    Hoermann, D.

    1980-01-01

    In cooperation with the 'VEB Transformatoren- und Roentgenwerk Hermann Matern', Dresden, an adjustable radiation protection device has been developed. This supplementary equipment for fluoroscopes ensures a sufficient protection of the gonads against undesirable X radiation, can be handled easily and does not annoy patients, esp. children

  17. Verification of electromagnetic effects from wireless devices in operating nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Song Hae; Kim, Young Sik; Lyou, Ho Sun; Kim, Min Suk [Korea Hydro and Nuclear Power Co. (KHNP), Central Research Institute, Daejeon (Korea, Republic of); Lyou, Joon [Dept. of Electronics Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2015-10-15

    Wireless communication technologies, especially smart phones, have become increasingly common. Wireless technology is widely used in general industry and this trend is also expected to grow with the development of wireless technology. However, wireless technology is not currently applied in any domestic operating nuclear power plants (NPPs) because of the highest priority of the safety policy. Wireless technology is required in operating NPPs, however, in order to improve the emergency responses and work efficiency of the operators and maintenance personnel during its operation. The wired telephone network in domestic NPPs can be simply connected to a wireless local area network to use wireless devices. This design change can improve the ability of the operators and personnel to respond to an emergency situation by using important equipment for a safe shutdown. IEEE 802.11 smart phones (Wi-Fi standard), Internet Protocol (IP) phones, personal digital assistant (PDA) for field work, notebooks used with web cameras, and remote site monitoring tablet PCs for on-site testing may be considered as wireless devices that can be used in domestic operating NPPs. Despite its advantages, wireless technology has only been used during the overhaul period in Korean NPPs due to the electromagnetic influence of sensitive equipment and cyber security problems. This paper presents the electromagnetic verification results from major sensitive equipment after using wireless devices in domestic operating NPPs. It also provides a solution for electromagnetic interference/radio frequency interference (EMI/RFI) from portable and fixed wireless devices with a Wi-Fi communication environment within domestic NPPs.

  18. Verification of electromagnetic effects from wireless devices in operating nuclear power plants

    Directory of Open Access Journals (Sweden)

    Song-Hae Ye

    2015-10-01

    Full Text Available Wireless communication technologies, especially smartphones, have become increasingly common. Wireless technology is widely used in general industry and this trend is also expected to grow with the development of wireless technology. However, wireless technology is not currently applied in any domestic operating nuclear power plants (NPPs because of the highest priority of the safety policy. Wireless technology is required in operating NPPs, however, in order to improve the emergency responses and work efficiency of the operators and maintenance personnel during its operation. The wired telephone network in domestic NPPs can be simply connected to a wireless local area network to use wireless devices. This design change can improve the ability of the operators and personnel to respond to an emergency situation by using important equipment for a safe shutdown. IEEE 802.11 smartphones (Wi-Fi standard, Internet Protocol (IP phones, personal digital assistant (PDA for field work, notebooks used with web cameras, and remote site monitoring tablet PCs for on-site testing may be considered as wireless devices that can be used in domestic operating NPPs. Despite its advantages, wireless technology has only been used during the overhaul period in Korean NPPs due to the electromagnetic influence of sensitive equipment and cyber security problems. This paper presents the electromagnetic verification results from major sensitive equipment after using wireless devices in domestic operating NPPs. It also provides a solution for electromagnetic interference/radio frequency interference (EMI/RFI from portable and fixed wireless devices with a Wi-Fi communication environment within domestic NPPs.

  19. Verification of electromagnetic effects from wireless devices in operating nuclear power plants

    International Nuclear Information System (INIS)

    Ye, Song Hae; Kim, Young Sik; Lyou, Ho Sun; Kim, Min Suk; Lyou, Joon

    2015-01-01

    Wireless communication technologies, especially smart phones, have become increasingly common. Wireless technology is widely used in general industry and this trend is also expected to grow with the development of wireless technology. However, wireless technology is not currently applied in any domestic operating nuclear power plants (NPPs) because of the highest priority of the safety policy. Wireless technology is required in operating NPPs, however, in order to improve the emergency responses and work efficiency of the operators and maintenance personnel during its operation. The wired telephone network in domestic NPPs can be simply connected to a wireless local area network to use wireless devices. This design change can improve the ability of the operators and personnel to respond to an emergency situation by using important equipment for a safe shutdown. IEEE 802.11 smart phones (Wi-Fi standard), Internet Protocol (IP) phones, personal digital assistant (PDA) for field work, notebooks used with web cameras, and remote site monitoring tablet PCs for on-site testing may be considered as wireless devices that can be used in domestic operating NPPs. Despite its advantages, wireless technology has only been used during the overhaul period in Korean NPPs due to the electromagnetic influence of sensitive equipment and cyber security problems. This paper presents the electromagnetic verification results from major sensitive equipment after using wireless devices in domestic operating NPPs. It also provides a solution for electromagnetic interference/radio frequency interference (EMI/RFI) from portable and fixed wireless devices with a Wi-Fi communication environment within domestic NPPs

  20. Implantable Medical Devices; Networking Security Survey

    Directory of Open Access Journals (Sweden)

    Siamak Aram

    2016-08-01

    Full Text Available The industry of implantable medical devices (IMDs is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable devices is rather advanced, the issue of equipping the IMDs with sufficiently strong security system remains unresolved. In fact, IMDs have relatively weak security mechanisms which render them vulnerable to cyber-attacks that compromise the quality of IMDs’ functionalities. This study revolves around the security deficiencies inherent to three types of sensor-based medical devices; biosensors, insulin pump systems and implantable cardioverter defibrillators. Manufacturers of these devices should take into consideration that security and effectiveness of the functionality of implants is highly dependent on the design. In this paper, we present a comprehensive study of IMDs’ architecture and specifically investigate their vulnerabilities at networking interface.

  1. Automatic coordination of protection devices in distribution system

    International Nuclear Information System (INIS)

    Comassetto, L.; Bernardon, D.P.; Canha, L.N.; Abaide, A.R.

    2008-01-01

    Among the several components of distribution systems, protection devices present a fundamental importance, since they aim at keeping the physical integrity not only of the system equipment, but also of the electricians' team and the population in general. The existing tools today in the market that carry out the making of protection studies basically draw curves, and need direct user's interference for the protection devices adjustment and coordination analyses of selectivity, being susceptible to the user's mistakes and not always considering the best technical and economical application. In Brazil, the correct application of the protection devices demand a high amount of time, being extremely laborious due to the great number of devices (around 200 devices), besides the very dynamic behaviour of distribution networks and the need for constant system expansion. This article presents a computational tool developed with the objective of automatically determining the adjustments of all protection devices in the distribution networks to obtain the best technical application, optimizing its performance and making easier protection studies. (author)

  2. Optimizing the construction of devices to control inaccesible surfaces - case study

    Science.gov (United States)

    Niţu, E. L.; Costea, A.; Iordache, M. D.; Rizea, A. D.; Babă, Al

    2017-10-01

    The modern concept for the evolution of manufacturing systems requires multi-criteria optimization of technological processes and equipments, prioritizing associated criteria according to their importance. Technological preparation of the manufacturing can be developed, depending on the volume of production, to the limit of favourable economical effects related to the recovery of the costs for the design and execution of the technological equipment. Devices, as subsystems of the technological system, in the general context of modernization and diversification of machines, tools, semi-finished products and drives, are made in a multitude of constructive variants, which in many cases do not allow their identification, study and improvement. This paper presents a case study in which the multi-criteria analysis of some structures, based on a general optimization method, of novelty character, is used in order to determine the optimal construction variant of a control device. The rational construction of the control device confirms that the optimization method and the proposed calculation methods are correct and determine a different system configuration, new features and functions, and a specific method of working to control inaccessible surfaces.

  3. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  4. Blast Analysis of Laminated Glass Curtain Walls Equipped by Viscoelastic Dissipative Devices

    Directory of Open Access Journals (Sweden)

    Chiara Bedon

    2012-09-01

    Full Text Available Nonlinear numerical simulations are reported for a conventional unitized laminated glass curtain wall subjected to high- and low-level air blast loading. The studied curtain wall, spanning floor to floor, consisted of a laminated glass panel, a continuous bead of structural silicone sealant, a split screw spline frame and four rigid brackets. Firstly, a linear elastic FE-model (M01 is presented to investigate dynamic stresses and deflections due to explosion, by taking into account geometrical nonlinearities. Since, in similar glazing systems, it is important to take into account the possible cracking of glass lites, a second model (M02, calibrated to previous experimental data, is proposed. In it, glass behaves as a brittle-elastic material, whereas an elastoplastic characteristic curve is assumed for mullions. As a result, the design explosion seriously affects the main components of the curtain wall, especially the bead of silicone. To address these criticalities, additional viscoelastic (VE devices are installed at the frame corners (M03. Their effectiveness explains the additional deformability provided to the conventional curtain wall, as well as the obvious dissipation of the incoming energy due to blast loading. Structural and energy capabilities provided by devices are highlighted by means of numerical simulations.

  5. IR IMAGING AND VIBRATORY METHODS OF CONTROL AND DIAGNOSTICS OF THE EQUIPMENT AT OJSC «BSW – MANAGEMENT COMPANY OF HOLDING «BMC»

    Directory of Open Access Journals (Sweden)

    A. S. Shinkarev

    2017-01-01

    Full Text Available The article discusses the main methods of diagnostics of the equipment of OJSC «BSW – management company of holding «BMC». Presents results of diagnostics of various equipment with the description of the devices directly used for the diagnostic that can detect various defects of the equipment at the stage of their origination. Describes the advantages of these methods compared to other methods of control and diagnostics.

  6. Are new supraglottic airway devices, tracheal tubes and airway viewing devices cost-effective?

    Science.gov (United States)

    Slinn, Simon J; Froom, Stephen R; Stacey, Mark R W; Gildersleve, Christopher D

    2015-01-01

    Over the past two decades, a plethora of new airway devices has become available to the pediatric anesthetist. While all have the laudable intention of improving patient care and some have proven clinical benefits, these devices are often costly and at times claims of an advantage over current equipment and techniques are marginal. Supraglottic airway devices are used in the majority of pediatric anesthetics delivered in the U.K., and airway-viewing devices provide an alternative for routine intubation as well as an option in the management of the difficult airway. Yet hidden beneath the convenience of the former and the technology of the latter, the impact on basic airway skills with a facemask and the lack of opportunities to fine-tune the core skill of intubation represent an unrecognised and unquantifiable cost. A judgement on this value must be factored into the absolute purchase cost and any potential benefits to the quality of patient care, thus blurring any judgement on cost-effectiveness that we might have. An overall value on cost-effectiveness though not in strict monetary terms can then be ascribed. In this review, we evaluate the role of these devices in the care of the pediatric patient and attempt to balance the advantages they offer against the cost they incur, both financial and environmental, and in any quality improvement they might offer in clinical care. © 2014 John Wiley & Sons Ltd.

  7. Establishment of Experimental Equipment for Training of Professionals in the Nuclear Radiation Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, S. K.; Seo, K. W.; Joo, Y. C.; Kim, I. C.; Woo, C. K.; Yoo, B. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-09-15

    The main purpose of this project is to establish experimental equipment for training of professionals and students in the field of radiation measurement, and settle the foundation for the advanced education system and program. The priority for the experimental equipment had been deduced by reviewing of the Nuclear Training and Education Center of KAERI and other country's training courses. Equipment for training of radiation professionals are High-Purity Germanium spectroscopic systems, alpha analyzers, and hand-held gamma/neutron inspector systems. For the basic experiments, electric personal dosimeters and a reader, radiation survey meters, and various alpha, beta and gamma radiation isotopes have been equipped. Some old or disused equipment and devices were disposed and re-arranged, and a new experiment lab had been settled for gamma spectroscopy. Along with the preparation of equipment, 14 experimental modules have been selected for practical and essential experiments training to professionals from industries, universities and research organizations. Among the modules, 7 important experiment notes had been prepared in Korea and also in English. As a consequence, these advanced radiation experimental setting would be a basis to cooperate with IAEA or other countries for international training courses. These activities would be a foundation for our contribution to the international nuclear society and for improving our nuclear competitiveness. The experimental equipment and application notes developed in this study will be used also by other training institutes and educational organizations through introducing and encouraging to use them to the nuclear society.

  8. Establishment of Experimental Equipment for Training of Professionals in the Nuclear Radiation Measurement

    International Nuclear Information System (INIS)

    Ahn, S. K.; Seo, K. W.; Joo, Y. C.; Kim, I. C.; Woo, C. K.; Yoo, B. H.

    2008-09-01

    The main purpose of this project is to establish experimental equipment for training of professionals and students in the field of radiation measurement, and settle the foundation for the advanced education system and program. The priority for the experimental equipment had been deduced by reviewing of the Nuclear Training and Education Center of KAERI and other country's training courses. Equipment for training of radiation professionals are High-Purity Germanium spectroscopic systems, alpha analyzers, and hand-held gamma/neutron inspector systems. For the basic experiments, electric personal dosimeters and a reader, radiation survey meters, and various alpha, beta and gamma radiation isotopes have been equipped. Some old or disused equipment and devices were disposed and re-arranged, and a new experiment lab had been settled for gamma spectroscopy. Along with the preparation of equipment, 14 experimental modules have been selected for practical and essential experiments training to professionals from industries, universities and research organizations. Among the modules, 7 important experiment notes had been prepared in Korea and also in English. As a consequence, these advanced radiation experimental setting would be a basis to cooperate with IAEA or other countries for international training courses. These activities would be a foundation for our contribution to the international nuclear society and for improving our nuclear competitiveness. The experimental equipment and application notes developed in this study will be used also by other training institutes and educational organizations through introducing and encouraging to use them to the nuclear society

  9. Challenges and Prospects of Equipment Health Monitoring with Wireless Sensor Network in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Chen, Dongyi; Jiang, Jin; Bari, Ataul; Wang, Quan; Hashemian, Hash-M.

    2014-01-01

    A wireless sensor network (WSN) system can offer tremendous benefits to equipment condition monitoring in newly-constructed and/or refurbished nuclear power plants (NPPs). However, it has not been widely accepted so far because of the following requirements by the NPP operators ectromagnetic (EM) emissions from the wireless transceivers must not interfere with the functionalities of the sensitive safety and protection systems in the plant, WSN must perform reliably in the presence of high levels of EM interference from devices such as relays and motor driven pumps, and ionizing radiation sources, dependable WSN performance in harsh industrial environments that are cluttered with cable trays, piping, valves, pumps, motors, and concrete and steel structures, and trict compliance with nuclear regulatory guidelines on EM emissions by the wireless devices. This paper will review the key issues associated with the deployment of WSN for equipment condition monitoring in NPPs. Some promising WSN technologies that can be used in NPP applications are also discussed

  10. Automation and mechanization of in-service inspection of selected equipment in FRG's nuclear power plants

    International Nuclear Information System (INIS)

    Metke, E.

    1988-01-01

    The procedures and equipment are described for the automation and mechanization of in-service inspection in nuclear power plants in the FRG, used by the KWU company. Checks of the pressure vessel are done by visual means using a colour tv camera, the method of eddy currents and the ultrasonic method. An analysis is made of the time schedule of ultrasonic inspections, and the central column manipulator is described which allows to check all internal regions of the pressure vessel. Attention is also devoted to other devices, e.g., those for prestressing shanks, cleaning shanks, cleaning thread apertures, etc. A combined probe using the ultrasonic method and the eddy current method serves the inspection of heat exchange tubes in the steam generator. For inspecting the primary circuit the KWU company uses devices for checking and working the inner surface of pipes. Briefly described are examples of using KWU equipment in nuclear power plants in CMEA countries. (Z.M.). 11 figs., 6 refs

  11. Challenges and Prospects of Equipment Health Monitoring with Wireless Sensor Network in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Dongyi [University of Electronic Science and Technology of China, Chengdu (China); Jiang, Jin; Bari, Ataul; Wang, Quan [University of Western Ontario, Ontario (Canada); Hashemian, Hash-M. [AMS Technology Center Knoxville (United States)

    2014-08-15

    A wireless sensor network (WSN) system can offer tremendous benefits to equipment condition monitoring in newly-constructed and/or refurbished nuclear power plants (NPPs). However, it has not been widely accepted so far because of the following requirements by the NPP operators ectromagnetic (EM) emissions from the wireless transceivers must not interfere with the functionalities of the sensitive safety and protection systems in the plant, WSN must perform reliably in the presence of high levels of EM interference from devices such as relays and motor driven pumps, and ionizing radiation sources, dependable WSN performance in harsh industrial environments that are cluttered with cable trays, piping, valves, pumps, motors, and concrete and steel structures, and trict compliance with nuclear regulatory guidelines on EM emissions by the wireless devices. This paper will review the key issues associated with the deployment of WSN for equipment condition monitoring in NPPs. Some promising WSN technologies that can be used in NPP applications are also discussed.

  12. Device for measuring the exposure time in dental X-ray - Cronox

    International Nuclear Information System (INIS)

    Menezes, Claudio J.M.; Santos, Luiz A.P. dos

    2009-01-01

    The Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) developed a test device for monitoring the X-ray beam in dental equipment to its application in quality control programs. This device, called Odontologic Dosimetric Card (CDO of Cartao Dosimetrico Odontologico in Portuguese) uses thermoluminescent dosimeters (TLD) for the measurement of some parameters of the X-ray beam as the entrance surface dose, the peak tension and half value layer (HVL). Radiographic films record the size of the radiation field. However, the TLD does not allow the assessment of exposure time, a parameter that complements the requirements of the Diretrizes de Protecao Radiologica em Radiodiagnostico Medico e Odontologico of Department of Health in Brazil for such equipment. Thus was developed a system based on sensitivity to ionizing radiation of phototransistors for measurement of exposure time when a patient is put in a clinical dental radiography. The system, called CRONOX was sized to be inserted within the CDO. The results showed that the measuring error had developed for less than 3% when compared to reference values obtained with the Tektronix digital oscilloscope, TDS2022 model. The readings obtained with the CRONOX were also compared with the nominal values selected in the X-ray equipment and with the values measured with the instrument of trade PTW Diavolt Universal. The results showed that the measuring device developed showed a maximum deviation of 5.92% on the nominal value selected, while for the instrument of PTW was 17.86%. (author)

  13. 30 CFR 77.506-1 - Electric equipment and circuits; overload and short circuit protection; minimum requirements.

    Science.gov (United States)

    2010-07-01

    ... short circuit protection; minimum requirements. 77.506-1 Section 77.506-1 Mineral Resources MINE SAFETY...-1 Electric equipment and circuits; overload and short circuit protection; minimum requirements. Devices providing either short circuit protection or protection against overload shall conform to the...

  14. Enhancing reactor availability factor by diagnostic monitoring and data acquisition of electrical equipments

    International Nuclear Information System (INIS)

    Singh, G.

    2006-01-01

    Electrical energy has made significant contribution to rapid growth of industrial activity in the country. Development and improvement of energy conversion devices or electrical apparatus have supported the growth. Reliability is probably the most important factor in electrical supply system, not only to give uninterrupted service but to provide an economic supply. Regular diagnostic testing of electrical equipments will make a significant contribution to the reliability of electrical supply. The purpose of diagnostic monitoring is to recognize the development of faults at an early stage, which consequently allows greater freedom to schedule the outages resulting in lower downtime and lower capitalized losses. The insulation constitutes the heart of any electrical/power equipment. The insulation in power equipment in normal condition undergoes certain changes in the physical, chemical, electrical and mechanical properties. The change with respect to time in the presence of an influencing factor, more often a stress (electrical) is referred to as ageing. The deterioration of insulating material plays an important role in the assessing the condition of electrical equipments. The systematic diagnostic tests are also part of the maintenance program to ensure the continued serviceability of electrical equipments, by replacing or repairing the components likely to fail, as revealed by the test. Diagnostic tests are carried out on various electrical equipments for detection of incipient fault, location and judging their severity. (author)

  15. Vibration aging of diesel-engine mounted electrical equipment

    International Nuclear Information System (INIS)

    Lee, B.J.; Morton, W.C.

    1994-01-01

    The Emergency Diesel Generator (EDG) in a Nuclear Power Plant is considered to be a component which is essential to safe plant operation. Failures of auxiliary equipment directly mounted on the EDG creates costly repairs, and compromises the engine's availability and reliability. Although IEEE-323 requires addressing of safety-related components due to mechanically induced vibration, very few guidelines exist in the nuclear industry to show how this may be accounted for. Most engine vendors rely on the empirical experience data as the basis of their evaluation for vibration. Upgrade of engine controls, addition of monitoring devices and other engine modifications require design and installation of new equipment to be mounted directly on the engine. This necessitates the evaluation for engine-induced vibration which is considered to be one of the most severe design parameters. This paper discusses the engine vibration characteristics, and the acquisition of extensive field vibration data on the diesel engine under operating conditions. The data is then used to develop life cycle vibration qualification test profiles that can be applied with confidence in a laboratory environment to qualify engine-mounted equipment. The intent is to validate a product's ability to survive under worst case, extended service on-engine conditions. This paper describes the procedures and approaches used to achieve those goals, and provides developed profile examples and test results

  16. Design of active feedback for rehabilitation device

    Directory of Open Access Journals (Sweden)

    Liska Ondrej

    2016-01-01

    Full Text Available Sensor systems are an essential part of automated equipment. They are even more important in machines that come in contact with people, because they have a significant impact on safety. This paper describes the design of active feedback for rehabilitation device driven by pneumatic artificial muscles. Here are presented three methods for measuring the load of the robot. The first is a system composed of Force Sensitive Resistors (FSR placed in the handle of the device. Two other methods are intended to measure the load of the actuator composed of artificial muscles. The principle of one method is to measure the difference in filling pressures of the muscles, second is based on strain measurement in the drive cables. The paper describes advantages and disadvantages of using each of these methods in a rehabilitation device

  17. Scientific Equipment Division - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2001-01-01

    Full text: The Scientific Equipment Division consists of the Design Group and the Mechanical Workshop. The activity of the Division includes the following: - designing of devices and equipment for experiments in physics, their mechanical construction and assembly. In particular, there are vacuum chambers and installations for HV and UHV; - maintenance and upgrading of the existing installations and equipment in our Institute; - participation of our engineers and technicians in design works, equipment assembly and maintenance for experiments in foreign laboratories. The Design Group is equipped with PC-computers and AutoCAD graphic software (release 2000 and Mechanical Desktop 4.0) and a AO plotter, what allows us to make drawings and 2- and 3-dimensional mechanical documentation to the world standards. The Mechanical Workshop can offer a wide range of machining and treatment methods with satisfactory tolerances and surface quality. It offers the following possibilities: - turning - cylindrical elements of a length up to 2000 mm and a diameter up to 400 mm, and also disc-type elements of a diameter up to 600 mm and a length not exceeding 300 mm; - milling - elements of length up to 1000 mm and gear wheels of diameter up to 300 mm; - grinding - flat surfaces of dimensions up to 300 mm x 1000 mm and cylindrical elements of a diameter up to 200 mm and a length up to 800 mm; - drilling - holes of a diameter up to 50 mm; - welding - electrical and gas welding, including TIG vacuum-tight welding; - soft and hard soldering; - mechanical works including precision engineering; - plastics treatment - machining and polishing using diamond milling, modelling, lamination of various shapes and materials, including plexiglas, scintillators and light-guides; - painting - paint spraying with possibility of using furnace-fred drier of internal dimensions of 800 mm x 800 mm x 800 mm. Our workshop posses CNC milling machine which can be used for machining of work-pieces up to 500 kg

  18. Design, modelling and simulation aspects of an ankle rehabilitation device

    Science.gov (United States)

    Racu, C. M.; Doroftei, I.

    2016-08-01

    Ankle injuries are amongst the most common injuries of the lower limb. Besides initial treatment, rehabilitation of the patients plays a crucial role for future activities and proper functionality of the foot. Traditionally, ankle injuries are rehabilitated via physiotherapy, using simple equipment like elastic bands and rollers, requiring intensive efforts of therapists and patients. Thus, the need of robotic devices emerges. In this paper, the design concept and some modelling and simulation aspects of a novel ankle rehabilitation device are presented.

  19. Experimental Research of a New Wave Energy Conversion Device

    Science.gov (United States)

    Lu, Zhongyue; Shang, Jianzhong; Luo, Zirong; Sun, Chongfei; Chen, Gewei

    2018-01-01

    With the increasing tension of contemporary social energy, the development and utilization of renewable energy has become an important development direction. As an important part of renewable energy, wave energy has the characteristics of green environmental protection and abundant reserves, attracting more investment and research. For small marine equipment energy supply problem, this paper puts forward a micro wave energy conversion device as the basic of heaving motion of waves in the ocean. This paper designed a new type of power output device can solve the micro wave energy conversion problem.

  20. A new procedure for making TEM specimens of superconductor devices

    International Nuclear Information System (INIS)

    Huang, Y.; Merkle, K.L.

    1997-04-01

    A new procedure is developed for making TEM specimens of thin film devices. In this procedure the sample is flatly polished to an overall ion-mill-ready thickness so that any point in the 2-D sample pane can be thinned to an electron-transparent thickness by subsequent ion-milling. Using this procedure, small regions of interest can be easily reached in both cross-section and plan-view samples. This is especially useful in device studies. Applications of this procedure to the study of superconductor devices yield good results. This procedure, using commercially available equipment and relatively cheap materials, is simple and easy to realize

  1. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  2. Hardware Module for the Security Enhancement of Optical Telecom Network Equipment

    International Nuclear Information System (INIS)

    Nadeem; Ali, M.

    2015-01-01

    The telecommunication equipment physical security threats have increased not only in Pakistan but also anywhere in the world and hence, reducing the revenue. This new challenging and alarming situation is created for the telecom network provider. The main focus of this paper is to provide a low cost economical design for reducing the theft of the costly telecommunication equipment like optical network units (ONU). This system is based on instant messaging on the mobile in the event of theft through GSM modem. The proposed security module is dynamic, flexible and can also be integrated in the existing networks and separately having its own independent low power consumption source. The module will continuously work successfully under different scenarios such as completely isolated from other devices by power break down or by fibre cut. (author)

  3. Use of Industrial Components in SL/BT Equipment Controls

    CERN Document Server

    Carlier, E

    1999-01-01

    The control system of all SPS target stations, beam absorbers and other aperture limiting devices is presently being refurbished, using solely standard industrial hardware and software components. SIEMENS Simatic S7-300 programmable logic controllers serve as equipment controllers. They are connected through Profibus to a WinNT front-end running the SIEMENS WinCC SCADA package which acts as local controller and gateway for remote access. A variant configuration, where the PLCs are directly linked to Ethernet, has been used for controlling the SPS Q measurement kickers. These and some other SL/BT projects will be reviewed where fully off-the-shelf components have been successfully integrated into the SL accelerator controls infrastructure. The arguments leading to the various technical choices will be laid down including a report of the experience gained. Finally, the presentation will address the perspective and current ideas for using industrial components in controlling SL/BT equipment during the LHC era.

  4. Application of risk-based inspection methods for cryogenic equipment

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    Risk-based Inspection (RBI) is widely applied across the world as part of Pressure Equipment Integrity Management, especially in the oil and gas industry, to generally reduce costs compared with time-based approaches and assist in assigning resources to the most critical equipment. One of the challenges in RBI is to apply it for low temperature and cryogenic applications, as there are usually no degradation mechanisms by which to determine a suitable probability of failure in the overall risk assessment. However, the assumptions used for other degradation mechanisms can be adopted to determine, qualitatively and semi-quantitatively, a consequence of failure within the risk assessment. This can assist in providing a consistent basis for the assumptions used in ensuring adequate process safety barriers and determining suitable sizing of relief devices. This presentation will discuss risk-based inspection in the context of cryogenic safety, as well as present some of the considerations for the risk assessme...

  5. Department of Nuclear Equipment '' High Technology Center - HITEC '' - Overview

    International Nuclear Information System (INIS)

    Krawczyk, P.

    2010-01-01

    Full text: The Department of Nuclear Equipment, also known under the brand '' HITEC '' plays a unique role in the Institute. It combines research and development with manufacturing activities in the area of accelerator technology applications in medicine and industrial radiography. In 2010, the Department continued intense development efforts in the framework of Project No. POIG.01.01-14-012/08-00 (known under the short name of '' Accelerators and Detectors '') funded by EU Structural Funds. As described in detail elsewhere in this Report, these efforts resulted in substantial progress in the design and manufacture of the first model of a medical multi-energy accelerator for advanced radiotherapy. This model is an important testbed for a number of technologies and solutions that will be implemented in the final accelerator. Also, design and manufacture of the elements for an intra-surgery accelerator was carried out. It is worth noting that participation in the '' Accelerators and Detectors '' Project allowed HITEC to modernize significantly its manufacturing and testing capabilities. In 2010, the new equipment was successfully implemented for use in a manufacturing regime. The year 2010 also saw the completion of two R(and)D projects co-financed by the Polish Ministry of Science and Higher Education: · Multileaf Collimator as a Precision Device for Irradiation Field Delimiting in Medical Accelerators; · 4? Recessed Ionization Chamber with Internal Power Supply. In both cases, full scale prototypes of the respective devices were manufactured. In response to market interest HITEC started in 2010 a concept study of a compact low energy industrial radiography accelerator. Subsequently, HITEC received an order to develop and manufacture such a device and the development work was started. On completion the new device will extend the range of commercially available accelerators. In parallel to the above, HITEC continued to extend its engagement in scientific

  6. Transcatheter Device Closure of Patent Ductus Arteriosus

    International Nuclear Information System (INIS)

    Sultan, M.; Ullah, M.; Sadiq, N.; Akhtar, K.; Akbar, H.

    2014-01-01

    Objective: To determine the efficacy, safety and immediate complications encountered during percutaneous device closure of patent ductus arteriosus (PDA). Study Design: Case series. Place and Duration of Study: Department of Paediatric Cardiology, AFIC/NIHD, Rawalpindi, from January 2005 to December 2010. Methodology: Consecutive 500 patients who underwent attempted transcatheter PDA device closure were included in the study. Device type position, success of closure and complications were described as frequency percentage. Results: In 491 cases (98.2%), PDA was successfully occluded including 4 cases (0.8%) where devices were dislodged but retrieved and redeployed in Cath laboratory. PDA occluder devices used in 448 cases (91%) while coils (single or multiple) were used in 42 cases (8.5%) and in one case (0.2%) ASD occluder device was used to occlude the PDA. There were 09 (1.8%) unsuccessful cases, 06 (1.2%) were abandoned as ducts were considered unsuitable for device closure, 02 (0.4%) devices dislodged and needed surgical retrieval and one case (0.2%) was abandoned due to faulty equipment. The narrowest PDA diameter ranged from 0.5 - 14 mm with mean of 4.5 +- 2.4 mm. There was a single (0.2%) mortality. Conclusion: Transcatheter occlusion of PDA by coil or occluder device is an effective therapeutic option with high success rate. Complication rate is low in the hands of skilled operators yet paediatric cardiac surgical back-up cover is mandatory. (author)

  7. Device for removal of oriented core

    Energy Technology Data Exchange (ETDEWEB)

    Shakhmalov, A.M.

    1981-05-04

    A device for removal of an oriented core, which contains an external core barrel, connected with a gear, a rock-crushing bit, nonrotary core-receiving pipe, and a core marker, placed in the core-receiving pipe and connected kinematically with the external core barrel and gear, is distinguished by the fact that in order to increase the accuracy of determination of the spatial orientation of the core the gear of the core barrel and the marker come in the form of an electric drill, and a magnetic compass witha remote-fix indicator is attached to its housing. The device is also distinguished by the fact that it is equipped with an auxillary marker positioned symmetrically with respect to the first one.

  8. Increasing the Usage of Personal Protective Equipments in Constructing Subway Stations: An Application of Social Marketing Model

    Directory of Open Access Journals (Sweden)

    M Shams

    2013-10-01

    Full Text Available Abstract Background & aim: Although the relationship between the use of personal protective equipment and the reduction of workplace injuries is well-known the use of these devices during operation by the staff is not so desirable. This study was based on a model of social marketing interventions to increase the use of safety devices and personal protection on the subway-station staff. Methods: The present quasi-experimental study was based on the results of a formative research consisted of a qualitative (exploring employees’ views through focus group discussions and a quantitative study (measuring attitudes and behaviors by questionnaire and checklist. Based on the formative research findings, a free package includes a helmet with a label containing the message, an anti-cut safety gloves, a dust mask, and an educational pamphlet were delivered to intervention group. After four weeks, the check list of observational behaviors in two constructing stations was completed and the results were compared with before intervention. The data were analyzed by paired t-test, t-test and logistic regression. Results: Three common behaviors were observed among staff not using caps, masks and gloves. The odds ratio for helmet and mask usage in the intervention group was more than other groups. After the intervention, the use of safety helmets and masks significantly increased (p < 0.05. The odds ratio for the use of helmets and masks after intervention in the intervention group was significantly higher than other groups (p < 0.05. Conclusion: The experimental basis of the safety devices and personal protection needs and demands of the audience, material and immaterial costs of the equipment, supplies, and promoting their use in the right place, can encourage the staff to continuously use the safety devices at workplace. Key Words: Workplace, Injuries, Personal Protective Equipment, Social Marketing

  9. Implementation of remote equipment at TMI-2 [Three Mile Island Unit 2

    International Nuclear Information System (INIS)

    Giefer, D.; Jeffries, A.B.

    1988-01-01

    Each of the remote vehicles in use, or planned for use, at Three Mile Island Unit 2 (TMI-2) during the period from 1984 to the present had certain distinct common features. These were proven to be desirable for remote application in the TMI-2 environment. Proper implementation requires consideration of the following: control systems, rigging systems, power supplies, operator/support interface, maintenance concerns, viewing systems, contamination control, and communications. Design and component fabrication of these features allowed deployment of each of the remote devices. This paper discusses these systems and their impact for the use of remote mobile equipment at TMI-2. In most cases, the means of implementation dictated the design features of the devices

  10. Regulation E 69-14. Monitoring requirements for medical devices

    International Nuclear Information System (INIS)

    2015-01-01

    In the 'Regulations for the State Evaluation and Registration of Medical Equipment' force (Hereinafter Rules) set forth in Chapter VII, Articles 79 and 86, the monitoring activity as one of the programs necessary for evaluating the safety and effectiveness of medical monitoring equipment. In the years 2008 and 2011 were approved and implemented by the Center for State Control of Medical Equipment (CCEEM) Regulations and -1.1 ER and ER-1 that support and regulatory requirements 'Control and monitoring of pacemakers and implantable defibrillators' and 'Assessment, recording and control after market surgical silicone implants,' which are specific to these products and have provided a useful result for the performance of the activity. Given the number and diversity of high-risk medical devices as implantable or sustain human life that are brought into our National Health System (SNS), a regulation establishing control over the behavior becomes necessary safety and effectiveness of this equipment during use, which provide inputs to risk management. The objective of this regulation is to establish the regulatory requirements for tracking medical equipment introduced in the NHS. The provisions of this Regulation is aimed at health institutions, to CECMED as manufacturers, suppliers, distributors and importers of medical equipment.

  11. Incore inspection device

    International Nuclear Information System (INIS)

    Ogisu, Tatsuki; Taguchi, Kosei.

    1995-01-01

    The device of the present invention can inspect surfaces of equipments in reactor water in a nuclear reactor in a state of atmospheric air. Namely, an inspection device is movable forwardly and backwardly in a water-proof vessel. An annular sucker with pleats is disposed to the outer side of a lid of the water-proof vessel. A television camera for an under water monitoring is disposed to the inner side of the lid of the water-proof vessel by way of a partitioning wall with lid. Transferring screws are disposed at the back and on the side of the water-proof vessel. In the device having such a constitution, (1) the inside of the water-proof vessel is at first made water-tight by closing the partitioning wall with lid, (2) the back and the side screws are operated by the guide of the underwater monitoring television camera, to transfer the water-proof vessel to the surface of the reactor core to be inspected, (3) the annular sucker with pleats is urged on the surface to be inspected by the back screw, to fix the water-proof vessel, (4) reactor water in a space of the annular sucker with pleats is discharged and replaced with air, and (5) the lid of the partition wall with lid is opened and the inspection device is disposed at a position of the underwater monitoring television camera, to inspect the surface to be inspected in a state of atmospheric air. (I.S.)

  12. ER-1A-DEL-92 regulation. Procedure for evaluation and registration of medical equipment

    International Nuclear Information System (INIS)

    2015-01-01

    The objectives of this regulation is to provide additional guidance on the method of evaluation and registration of a medical team, so it is used by manufacturers, health institutions, testing centers and other institutions related to the topic. The provisions of this regulation apply to domestically produced medical equipment in relation to the necessary assessment for registration purposes of a medical team. However, the evaluation process may require evaluations and tests not explicitly included in this regulation, so that at each stage of the process the Center for State Control of Medical Equipment (Center) set the requirements for each computer or device class in particular.

  13. Device for sampling radioactive and aggressive liquid and vaporous media

    International Nuclear Information System (INIS)

    Przibram, E.; Halm, G.

    1974-01-01

    The equipment enables the taking of samples even of radioactive media from a main pipeline in the through-flow in a closed system. A tap device is attached to the main pipeline which branches into two parts. The one branch contains the actual tap which is closed to both sides with snap closure coupling. It is only used for taking samples. The other branch bridges the tap position as a bypass so that a representative sample is always available. Both branches join up again and lead back to the main pipeline. The sampling can be used in a nuclear power plant for the determination of O 2 , CI, SiO 2 , and Cu. A millilitre collecting cylinder and a millipore filtration device can be connected to the tap for liquid sampling and solid analysis, respectively. The system can be extended to several tap positions. Permanent measuring equipment is attached to the bypass pipe to control the sample liquid. (DG) [de

  14. Advanced single-wafer sequential multiprocessing techniques for semiconductor device fabrication

    International Nuclear Information System (INIS)

    Moslehi, M.M.; Davis, C.

    1989-01-01

    Single-wafer integrated in-situ multiprocessing (SWIM) is recognized as the future trend for advanced microelectronics production in flexible fast turn- around computer-integrated semiconductor manufacturing environments. The SWIM equipment technology and processing methodology offer enhanced equipment utilization, improved process reproducibility and yield, and reduced chip manufacturing cost. They also provide significant capabilities for fabrication of new and improved device structures. This paper describes the SWIM techniques and presents a novel single-wafer advanced vacuum multiprocessing technology developed based on the use of multiple process energy/activation sources (lamp heating and remote microwave plasma) for multilayer epitaxial and polycrystalline semiconductor as well as dielectric film processing. Based on this technology, multilayer in-situ-doped homoepitaxial silicon and heteroepitaxial strained layer Si/Ge x Si 1 - x /Si structures have been grown and characterized. The process control and the ultimate interfacial abruptness of the layer-to-layer transition widths in the device structures prepared by this technology will challenge the MBE techniques in multilayer epitaxial growth applications

  15. Towed Optical Assessment Device (TOAD) Data to Support Benthic Habitat Mapping since 2001

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Optical validation data were collected using a Tethered Optical Assessment Device (TOAD), an underwater sled equipped with an underwater digital video camera and...

  16. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  17. Simple and inexpensive microfluidic devices for the generation of monodisperse multiple emulsions

    KAUST Repository

    Li, Erqiang

    2013-12-16

    Droplet-based microfluidic devices have become a preferred versatile platform for various fields in physics, chemistry and biology. Polydimethylsiloxane soft lithography, the mainstay for fabricating microfluidic devices, usually requires the usage of expensive apparatus and a complex manufacturing procedure. Here, we report the design and fabrication of simple and inexpensive microfluidic devices based on microscope glass slides and pulled glass capillaries, for generating monodisperse multiple emulsions. The advantages of our method lie in a simple manufacturing procedure, inexpensive processing equipment and flexibility in the surface modification of the designed microfluidic devices. Different types of devices have been designed and tested and the experimental results demonstrated their robustness for preparing monodisperse single, double, triple and multi-component emulsions. © 2014 IOP Publishing Ltd.

  18. EnTracked: Energy-Efficient Robust Position Tracking for Mobile Devices

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Jensen, Jakob Langdal; Godsk, Torben

    2009-01-01

    conditions and mobility, schedules position updates to both minimize energy consumption and optimize robustness. The realized system tracks pedestrian targets equipped with GPS-enabled devices. The system is configurable to realize different trade-offs between energy consumption and robustness. We provide...... of the mobile device. Furthermore, tracking has to robustly deliver position updates when faced with changing conditions such as delays due to positioning and communication, and changing positioning accuracy. This work proposes EnTracked --- a system that, based on the estimation and prediction of system...... extensive experimental results by profiling how devices consume power, by emulation on collected data and by validation in several real-world deployments. Results from this profiling show how a device consumes power while tracking its position. Results from the emulation indicate that the system can...

  19. Data communication equipment

    International Nuclear Information System (INIS)

    Kim, Hak Seon; Lee, Sang Mok

    1998-02-01

    The contents of this book are introduction of data communication on definition, purpose and history, information terminal about data communication system and data transmission system, data transmit equipment of summary, transmission cable, data port, concentrator and front-end processor, audio communication equipment like phones, radio communication equipment of summary on foundation of electromagnetic waves, AM transmitter, AM receiver, FM receiver and FM transmitter, a satellite and mobile communication equipment such as earth station, TT and C and Cellular phone, video telephone and new media apparatus.

  20. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  1. 30 CFR 75.518-1 - Electric equipment and circuits; overload and short circuit protection; minimum requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric equipment and circuits; overload and short circuit protection; minimum requirements. 75.518-1 Section 75.518-1 Mineral Resources MINE SAFETY... short circuit protection; minimum requirements. A device to provide either short circuit protection or...

  2. Designing of Roaming Protocol for Bluetooth Equipped Multi Agent Systems

    Science.gov (United States)

    Subhan, Fazli; Hasbullah, Halabi B.

    Bluetooth is an established standard for low cost, low power, wireless personal area network. Currently, Bluetooth does not support any roaming protocol in which handoff occurs dynamically when a Bluetooth device is moving out of the piconet. If a device is losing its connection to the master device, no provision is made to transfer it to another master. Handoff is not possible in a piconet, as in order to stay within the network, a slave would have to keep the same master. So, by definition intra-handoff is not possible within a piconet. This research mainly focuses on Bluetooth technology and designing a roaming protocol for Bluetooth equipped multi agent systems. A mathematical model is derived for an agent. The idea behind the mathematical model is to know when to initiate the roaming process for an agent. A desired trajectory for the agent is calculated using its x and y coordinates system, and is simulated in SIMULINK. Various roaming techniques are also studied and discussed. The advantage of designing a roaming protocol is to ensure the Bluetooth enabled roaming devices can freely move inside the network coverage without losing its connection or break of service in case of changing the base stations.

  3. Design and Construction of Equipment for Applying the Geophysical Prospecting Method Electric Tomography

    Directory of Open Access Journals (Sweden)

    Fabio Héctor Giraldo Sánchez

    2013-06-01

    Full Text Available Outlines the procedure for the design and construction of electric equipment for geophysical prospecting through electrical tomography method. The team is of average power, ensuring exploration depths quite suitable for applications and commercial and geotechnical studies. The device is essentially a DC voltage source of 500 volts that is able to provide a maximum current of 1 amp. It also contains a small charge current source of electrical currents counteract naturally found in the subsoil and are manifested as a difference in the surface potential. A general explanation of the geophysical method in question, helps to understand the basic principles of operation of the equipment and functions to be fulfilled. After building the team, we conducted a field data acquisition, in area near the town of Gachancipa Cundinamarca. The data from this equipment are processed with specialized software. The images obtained with the software presents the distributions of subsurface resistivity can be associated with the possible structures and geology of the study area.

  4. An accessible micro-capillary electrophoresis device using surface-tension-driven flow

    Science.gov (United States)

    Mohanty, Swomitra K.; Warrick, Jay; Gorski, Jack; Beebe, David J.

    2010-01-01

    We present a rapidly fabricated micro-capillary electrophoresis chip that utilizes surface-tension-driven flow for sample injection and extraction of DNA. Surface-tension-driven flow (i.e. passive pumping) injects a fixed volume of sample that can be predicted mathematically. Passive pumping eliminates the need for tubing, valves, syringe pumps, and other equipment typically needed for interfacing with microelectrophoresis chips. This method requires a standard micropipette to load samples before separation, and remove the resulting bands after analysis. The device was made using liquid phase photopolymerization to rapidly fabricate the chip without the need of special equipment typically associated with the construction of microelectrophoresis chips (e.g. cleanroom). Batch fabrication time for the device presented here was 1.5 h including channel coating time to suppress electroosmotic flow. Devices were constructed out of poly-isobornyl acrylate and glass. A standard microscope with a UV source was used for sample detection. Separations were demonstrated using Promega BenchTop 100 bp ladder in hydroxyl ethyl cellulose (HEC) and oligonucleotides of 91 and 118 bp were used to characterize sample injection and extraction of DNA bands. The end result was an inexpensive micro-capillary electrophoresis device that uses tools (e.g. micropipette, electrophoretic power supplies, and microscopes) already present in most labs for sample manipulation and detection, making it more accessible for potential end users. PMID:19425002

  5. Energy monitoring device for 1.5-2.4 MeV electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Fuochi, P.G., E-mail: fuochi@isof.cnr.i [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Lavalle, M.; Martelli, A. [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Kovacs, A. [Institute of Isotopes, HAS, P.O.Box 77, H-1525 Budapest (Hungary); Mehta, K. [Arbeiterstrandbad Strasse 72, Vienna, A-1210 (Austria); Kuntz, F.; Plumeri, S. [Aerial, Parc d' Innovation Rue Laurent Fries F-67400 Illkirch (France)

    2010-03-11

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  6. Energy monitoring device for 1.5-2.4 MeV electron beams

    Science.gov (United States)

    Fuochi, P. G.; Lavalle, M.; Martelli, A.; Kovács, A.; Mehta, K.; Kuntz, F.; Plumeri, S.

    2010-03-01

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  7. Multi-objective optimal power flow with FACTS devices

    International Nuclear Information System (INIS)

    Basu, M.

    2011-01-01

    This paper presents multi-objective differential evolution to optimize cost of generation, emission and active power transmission loss of flexible ac transmission systems (FACTS) device-equipped power systems. In the proposed approach, optimal power flow problem is formulated as a multi-objective optimization problem. FACTS devices considered include thyristor controlled series capacitor (TCSC) and thyristor controlled phase shifter (TCPS). The proposed approach has been examined and tested on the modified IEEE 30-bus and 57-bus test systems. The results obtained from the proposed approach have been compared with those obtained from nondominated sorting genetic algorithm-II, strength pareto evolutionary algorithm 2 and pareto differential evolution.

  8. Determining of the Optimal Device Lifetime using Mathematical Renewal Models

    Directory of Open Access Journals (Sweden)

    Knežo Dušan

    2016-05-01

    Full Text Available Paper deals with the operations and equipment of the machine in the process of organizing production. During operation machines require maintenance and repairs, while in case of failure or machine wears it is necessary to replace them with new ones. For the process of replacement of old machines with new ones the term renewal is used. Qualitative aspects of the renewal process observe renewal theory, which is mainly based on the theory of probability and mathematical statistics. Devices lifetimes are closely related to the renewal of the devices. Presented article is focused on mathematical deduction of mathematical renewal models and determining optimal lifetime of the devices from the aspect of expenditures on renewal process.

  9. Investigational research on welfare equipment needs/seeds adaptation; Fukushi kiki needs seeds tekigo chosa kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    At the advent of the aging society, investigated are images of welfare equipment to be developed. In the range where the use of welfare equipment is to be studied, the following are included: self care, excretion, transfer, and support of work other than care, as assistance to daily life; exercise function, communication function, and environment arrangement, as assistance to social participation. Of the images of the welfare equipment classified by the overall evaluation, the following are cited as what supports daily life: a lift usable even in the existing houses, a bump remover by which bumps in the house are removed without making large repairs, a urine collector for females, a training device to prevent urinary incontinence, reduction in the bed-fast elderly, a device to prevent bedsore, a system for safely watching demented old people, a system in which clothes are automatically washed, dried, and hanged on a hanger, etc. What supports social participation are a system for sports experience by virtual reality, sound user interface, etc. For the aged to be healthy physically and mentally, it is essential to be taken good care of and create things to live for by participating the society. For this, it is necessary that the government establish the public policies and that a people be conscious of welfare. 9 figs., 33 tabs.

  10. Remote handling recognition and display device

    International Nuclear Information System (INIS)

    Kimura, Motohiko.

    1979-01-01

    Purpose: To surely recognize the movements of remote handling equipments in a reactor by the use of a device in a simple structure. Constitution: A light emission surface and a light reception surface are provided, for example, putting therebetween a hook of a nob of a control rod as a remote control equipment. Depending on the position of the hook, there are two possible cases where the light can not arrive the light reception surface inhibited by the hook and where the light can be received not inhibited by the hook. By visually monitoring the presence or absence of the light reception from the outside of the reactor, the movement of the nob for the control rod can be recognized. Optical fibers connect the optical source with the light emission surface, and the light reception surface with the display surface. (Ikeda, J.)

  11. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  12. A study on surveillance equipment at the exit/entry control point of nuclear facility

    International Nuclear Information System (INIS)

    Park, C. S.; Kim, D. Y.; Cha, H. L.; Kim, H. D.; Hong, J. S.

    1999-01-01

    Exit/Entry control is an essential measure at both entrances of the protected area and vital area of nuclear facility at which physical protection is required under the relevant laws and regulations. Especially, when there are heavy traffics of personnel and process equipment in those areas, automated surveillance devices have to be introduced to timely and efficiently screen out internal and external adversaries from achieving their goals of stealing of nuclear material and/or sabotage of the facility. The major portion of this study involves with integration and processing of signals from radiation detector, metal detector, and image monitor. This integrated device together with positive personal identification device which will be reinforced in near future would contribute to the establishment of total exit/entry control point of nuclear facility

  13. Review of foreign equipment for powered support control

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Sobczyk, J

    1986-10-01

    A new generation of control systems are comparatively evaluated developed by Dowty, Hemscheidt and Thyssen-Siemens for powered supports and shield supports. Types of functions controlled by each system are discussed: support advancing (lowering support canopy, advancing, increasing pressure), control of support position, advancing chain conveyor. The following control systems are described: fully automatic control, remote control from a gate road, manual control from an adjacent support unit. Types of electronic equipment used in the control systems are described: microcomputers (8-bit CMOS device), 8-bit microcomputers, transmission systems, measuring instruments. Advantages of control systems developed and manufactured by the 3 companies are comparatively evaluated.

  14. Towards a uniform specification of light therapy devices for the treatment of affective disorders and use for non-image forming effects: Radiant flux.

    Science.gov (United States)

    Aarts, M P J; Rosemann, A L P

    2018-08-01

    For treating affective disorders like SAD, light therapy is used although the underlying mechanism explaining this success remains unclear. To accelerate the research on defining the light characteristics responsible for inducing a specific effect a uniform manner for specifying the irradiance at the eye should be defined. This allows a genuine comparison between light-affect studies. An important factor impacting the irradiance at the eye are the radiant characteristics of the used light therapy device. In this study the radiant fluxes of five different light therapy devices were measured. The values were weighted against the spectral sensitivity of the five photopigments present in the human eye. A measurement was taken every five minutes to control for a potential stabilizing effect. The results show that all five devices show large differences in radiant flux. The devices equipped with blue LED lights have a much lower spectral radiant flux than the devices equipped with a fluorescent light source or a white LED. The devices with fluorescent lamps needed 30 min to stabilize to a constant radiant flux. In this study only five devices were measured. Radiant flux is just the first step to identify uniform specifications for light therapy devices. It is recommended to provide all five α-opic radiant fluxes. Preferably, the devices should come with a spectral power distribution of the radiant flux. For the devices equipped with a fluorescent lamp it is recommended to provide information on the stabilization time. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Practical method for estimating road curvatures using onboard GPS and IMU equipment

    Science.gov (United States)

    Zamfir, S.; Drosescu, R.; Gaiginschi, R.

    2016-08-01

    This paper describes an experimental method to determine with high accuracy the curvature of a road segment, the turning radius of a car, and the discomfort level perceived by the passengers in the vehicle cabin when passing through a curve. For these experiments we used professional equipment provided with two GPS active antennas with 13 dB gain featuring non-contact 100 Hz speed and distance measurement, and a ten degree Inertial Measurement Unit (IMU) with dynamic orientation outputs. The same experimental measurements also usedthe low cost GPS equipment available on smartphones, domestic vehicle GPS devices, as well as an Arduino GPS shield in order to compare the results generated by professional equipment. The purpose of these experiments was also to establish if certain road curve sections were correctly executed in order to ensure the safety and comfort of passengers. Another use of the proposed method relates to the road accident reconstruction field, providing experts and forensics with an accurate method of measuring the roadway curvature at accident scenes or traffic events. The research and equipment described in this paper have been acquired and developed under a PhD studyand a European funded project won and elaborated by the authors.

  16. Research on application of mobile diesel equipment in underground mines (IV)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    This research commenced in 1994 for the purpose of providing safety and environmental measures of underground mines where the mobile diesel equipment are operating. In this last research year, researches on filtering of diesel particulate matter, design of underground layout and disaster prevention have been carried out. 1) A study to reduce DPM(Diesel Particulate Matter) emission: It was known that water scrubber is only one practical way to reduce DPM emission as of now. There are several kinds of the sophisticated DPM filters, but it is not practical yet to be used in underground equipment due to the many adverse effects of the devices such as tremendous increase of SOx, NOx and back pressure etc. 2) Design of underground layout and their maintenance: Layout of underground structure has to be designed based on rock mechanical analysis and the concept of active support has to be adopted considering the large openings are requested to accommodate heavy duty diesel equipment in underground. Rock bolt and shotcrete will be the most applicable method to support such a large dimensional tunnels. 3) A study for disaster prevention in the case of the underground fire: There are two categories of possible disaster or hazard in workings where diesel equipment are operating. One is the disasters by exhaust pollutants and the other is the underground fire. (author). 35 refs., 27 tabs., 56 figs.

  17. Design of hoisting device used in nuclear power plants. KTA safety engineering code. Draft amendment, as of 6/98

    International Nuclear Information System (INIS)

    1998-06-01

    The draft amendment specifies, according to the hazards involved, (a) the general provisions, (b) additional provisions supplementing the general provisions, (c) more stringent provisions relating to aggravated risks, applicable to lifting gear, and (d) additional requirements for elevators in reactor containments and refuelling equipment, to be taken into account in the design of hoisting device used in nuclear power plants. The term hoisting device in this context covers elevators, cranes, winches, trolleys, load carrying equipment, and LWR refuelling machines as are used in nuclear power plants. (orig./CB) [de

  18. 42 CFR 421.210 - Designations of regional carriers to process claims for durable medical equipment, prosthetics...

    Science.gov (United States)

    2010-10-01

    ..., Arizona, Washington, Oregon, Montana, Idaho, Utah, Wyoming, North Dakota, South Dakota, Nebraska, Kansas... based on sections 1834(a)(12) and 1834(h) of the Act, which authorize the Secretary to designate one... equipment (and related supplies) as defined in section 1861(n) of the Act; (2) Prosthetic devices (and...

  19. [Radiotherapy and implantable medical device: example of infusion pumps].

    Science.gov (United States)

    Abrous-Anane, S; Benhassine, S; Lopez, S; Cristina, K; Mazeron, J-J

    2013-12-01

    Indication for radiotherapy is often questioned for patients equipped with implantable medical devices like infusion pumps as the radiation tolerance is poor or not known. We report here on the case of a patient who we treated with pelvic radiotherapy for cervical cancer and who had an infusion pump in iliac fossa. We conducted a series of tests on five identical pumps that insured that the treatment protocol is harmless to the implanted device. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  20. Protective device for the head of a gushing well

    Energy Technology Data Exchange (ETDEWEB)

    Kutepov, A.I.; Prokopov, O.I.

    1982-01-01

    A protective device is proposed for the head of a gushing well. It includes a housing with assembly for attachment to the pipe string. It is distinguished by the fact that in order to simplify insulation of the device at the well head and to improve its reliable operation, the housing is made in the form of sections, each of which is made in the form of a crimped sleeve with upper and lower flanges on the ends. The lower flange is equipped with a guide bushing installed inside the sleeve and clamps for attaching it in relation to the upper flange.

  1. Informatics in radiology: Efficiency metrics for imaging device productivity.

    Science.gov (United States)

    Hu, Mengqi; Pavlicek, William; Liu, Patrick T; Zhang, Muhong; Langer, Steve G; Wang, Shanshan; Place, Vicki; Miranda, Rafael; Wu, Teresa Tong

    2011-01-01

    Acute awareness of the costs associated with medical imaging equipment is an ever-present aspect of the current healthcare debate. However, the monitoring of productivity associated with expensive imaging devices is likely to be labor intensive, relies on summary statistics, and lacks accepted and standardized benchmarks of efficiency. In the context of the general Six Sigma DMAIC (design, measure, analyze, improve, and control) process, a World Wide Web-based productivity tool called the Imaging Exam Time Monitor was developed to accurately and remotely monitor imaging efficiency with use of Digital Imaging and Communications in Medicine (DICOM) combined with a picture archiving and communication system. Five device efficiency metrics-examination duration, table utilization, interpatient time, appointment interval time, and interseries time-were derived from DICOM values. These metrics allow the standardized measurement of productivity, to facilitate the comparative evaluation of imaging equipment use and ongoing efforts to improve efficiency. A relational database was constructed to store patient imaging data, along with device- and examination-related data. The database provides full access to ad hoc queries and can automatically generate detailed reports for administrative and business use, thereby allowing staff to monitor data for trends and to better identify possible changes that could lead to improved productivity and reduced costs in association with imaging services. © RSNA, 2011.

  2. 76 FR 23255 - Federal Motor Vehicle Safety Standards; Lamps, Reflective Devices, and Associated Equipment

    Science.gov (United States)

    2011-04-26

    ... petitions for reconsideration from Harley-Davidson Motor Company (January 18, 2008) and Ford Motor Company... [Docket No. NHTSA-2007-28322] Federal Motor Vehicle Safety Standards; Lamps, Reflective Devices, and... part, the petitions for reconsideration of the December 4, 2007, final rule reorganizing Federal Motor...

  3. A new device for X-ray Diffraction analyses of irradiated materials

    International Nuclear Information System (INIS)

    Valot, Christophe; Blay, Thierry; Caillot, Laurent; Ferroud-Plattet, Marie Pierre

    2008-01-01

    A new X-Ray Diffraction (XRD) equipment is being implemented in the LECA (Cea - Cadarache) hot laboratory. The device will be dedicated to structural characterization on irradiated fuels, as PWR fuels, transmutation targets and innovative fuels. The paper will present the specific design that was decided in order to reduce the number of components in contaminated volume and to make servicing easier. The analytical performances of this new equipment will be illustrated on some model samples: -) micro-diffraction capabilities will be detailed on heterogeneous material; -) strain and stress analyses on fresh uranium oxide pellets. (authors)

  4. Haptic device development based on electro static force of cellulose electro active paper

    Science.gov (United States)

    Yun, Gyu-young; Kim, Sang-Youn; Jang, Sang-Dong; Kim, Dong-Gu; Kim, Jaehwan

    2011-04-01

    Haptic is one of well-considered device which is suitable for demanding virtual reality applications such as medical equipment, mobile devices, the online marketing and so on. Nowadays, many of concepts for haptic devices have been suggested to meet the demand of industries. Cellulose has received much attention as an emerging smart material, named as electro-active paper (EAPap). The EAPap is attractive for mobile haptic devices due to its unique characteristics in terms of low actuation power, suitability for thin devices and transparency. In this paper, we suggest a new concept of haptic actuator with the use of cellulose EAPap. Its performance is evaluated depending on various actuation conditions. As a result, cellulose electrostatic force actuator shows a large output displacement and fast response, which is suitable for mobile haptic devices.

  5. [Markers of dental children`s health in the application of therapeutic orthodontic equipment].

    Science.gov (United States)

    Пачевська, Аліса В; Білошицька, Аліна В

    Treatment of teeth anomalies using removable and non-removable orthodontic devices in children leads to complications such as caries, gingivitis, periodontitis, oral mucosa hyperplasia. Etiopathogenetical of these diseases can be associated with biochemical changes in the composition of saliva. To determine the activity of lysozyme and amylase in oral fluid in children when using a fixed and removable orthodontic devices. Amylase and lysozyme were studied in oral fluid. Analyzed the biochemical composition of the freshly samples of oral fluid that was obtained in the control, experimental group 1 and 2 (children ages 7-18 years, which were used medical non-removable and removable orthodontic devices). Saliva was collected at the beginning of the therapeutic use of orthodontic devices (the first day of treatment), on 3 and 6 months of treatment. Assessment of lysozyme activity was carried nephelometric method on the ability of lysozyme to dissolve indicator organism Micrococcus lysodeicticus. To construct a calibration graph using dry lysozyme company Sigma. Salivary amylase activity was determined by hydrolysis of starch. The results were subjected to statistical analysis by standard methods. Data processed using software packages applied statistical analysis Statistica 6.0, Microsoft Excel, 2003. The use of a fixed and removable orthodontic equipment led to a decrease in saliva amylase, major changes are observed on the 6th month of treatment. The activity of lysozyme in saliva decreased the mostin patients with a permanent equipment. Major changes were also recorded on the 6th month of treatment. Complications of orthodontic treatment teeth anomalies in children (caries, gingivitis, periodontitis) caused by changes in the biochemical composition of saliva. For the prevention of the emergence and development of these complications is necessary to control the level of amylase and lysozyme in the mouth.

  6. Apparatuses and methods of determining if a person operating equipment is experiencing an elevated cognitive load

    Science.gov (United States)

    Watkins, Michael L.; Keller, Paul Edwin; Amaya, Ivan A.

    2015-06-16

    A method of, and apparatus for, determining if a person operating equipment is experiencing an elevated cognitive load, wherein the person's use of a device at a first time is monitored so as to set a baseline signature. Then, at a later time, the person's use of the device is monitored to determine the person's performance at the second time, as represented by a performance signature. This performance signature can then be compared against the baseline signature to predict whether the person is experiencing an elevated cognitive load.

  7. Life Cycle Management for Equipments in Nuclear Plants Based on Reliability

    International Nuclear Information System (INIS)

    Wang Dalin; Sun Jinlong

    2012-01-01

    Majority of equipments in nuclear power stations are not un-repairable, but repaired after failures or maintained periodically and then returned to running. Along with aging or fatigue causes, duration between failures may be variable such as larger or shorter. Equipments failure occurrences are consistent with non-homogeneous Poisson process (NHPP), in which their failure rates are variable. We chose Weibull process to simplify the actual circumstances to obtain the optimal life cycle management plans approximately. In application we need to estimate parameters of Weibull process with existing data. Before that, trend test is necessary. Total time test (TTT) is an alternative. Trend test can determine whether the failure rate changes along operating time and whether the devices operated under imperfect or minimal repair. Parameters of Weibull process λ, β can be estimated by maximum likelihood estimation method. LCM model is designed to found an optimizing model for those aging equipments under minimal repair or imperfect maintenance with maximum economic or availability as objective function. The purpose is to establish the optimal replacement strategies. Periodical replacement is the most regular choice and so LCM model aims to calculate the optimal replacement periodical duration.

  8. Data acquisition and control of the 370 TBq high-pressure tritium doping device, TRIBA

    International Nuclear Information System (INIS)

    Pfeil, A.; Heer, H.; Laesser, R.; Klatt, K.H.

    1987-07-01

    The report is arranged as follows: After an introduction, the first section briefly discusses measured values obtained with the 37 TBq (10 3 Ci) doping device with a view to the enhanced measuring range that is achievable with the newly developed 370 TBq (10 4 Ci) device. Sections 3 and 4 explain the technical design of the device and the measuring and control equipment connected to the computer. All following sections are detailed descriptions of the computer configuration and the software. (orig./HP) [de

  9. Clarification of radiation-control regulations for diagnostic x-ray equipment

    International Nuclear Information System (INIS)

    1989-03-01

    The Office of Compliance and Surveillance of the Center for Devices and Radiological Health (CDRH) has received many requests for interpretation of the Federal regulations that relate to diagnostic x-ray equipment. Responses to these requests were originally issued as FDA Compliance Policy Guides, industry-wide letters, and letters to individuals. The document is a compilation of those responses that remain applicable. Guides or opinions that have been withdrawn or are now obsolete because they have been incorporated into the regulations are not included. The document consists of two sections: the General section, which contains information of a general nature; and the Specific section, which contains information specific to particular sections of the Federal Performance Standard for Diagnostic X-ray Equipment (21 CFR 1020.30-32). When the term 'Revised Language' appears in an item heading, it indicates English grammar correction; the term 'Revised' indicates an updated version of the original clarification

  10. 3D web based learning of medical equipment employed in intensive care units.

    Science.gov (United States)

    Cetin, Aydın

    2012-02-01

    In this paper, both synchronous and asynchronous web based learning of 3D medical equipment models used in hospital intensive care unit have been described over the moodle course management system. 3D medical equipment models were designed with 3ds Max 2008, then converted to ASE format and added interactivity displayed with Viewpoint-Enliven. 3D models embedded in a web page in html format with dynamic interactivity-rotating, panning and zooming by dragging a mouse over images-and descriptive information is embedded to 3D model by using xml format. A pilot test course having 15 h was applied to technicians who is responsible for intensive care unit at Medical Devices Repairing and Maintenance Center (TABOM) of Turkish High Specialized Hospital.

  11. Device for the radiation centering at electron emitters

    International Nuclear Information System (INIS)

    Panzer, S.; Ardenne, T. von; Jessat, K.; Bahr, G.

    1985-01-01

    The invention has been directed at a device for a simplified and reliable centering of electron beams at electron emitters in particular for welding and thermal surface modifications. The electron beam has been focussed relatively to an electron-optical lens. A movable masked electron detector has been arranged at the electron beam deflection plane. The electron detector is connected with an electronic data evaluation equipment

  12. Using a Raspberry Pi as a Versatile and Inexpensive Display Device

    Directory of Open Access Journals (Sweden)

    Edward Iglesias

    2013-07-01

    Full Text Available This article covers the process by which a library took some unused equipment and added a cheap computing device to produce very inexpensive but effective electronic signage. Hardware and software issues as well as a step-by-step guide through the process are included.

  13. Reactor water level measuring device

    International Nuclear Information System (INIS)

    Kuroki, Reiji; Asano, Tamotsu.

    1996-01-01

    A condensation vessel is connected to the upper portion of a reactor pressure vessel by way of a pipeline. The lower portion of the condensation vessel is connected to a low pressure side of a differential pressure transmission device by way of a reference leg pipeline. The high pressure side of the differential pressure transmission device is connected to the lower portion of the pressure vessel by way of a pipeline. The condensation vessel is equipped with a temperature sensor. When a temperature of a gas phase portion in the condensation vessel is lowered below a predetermined level, and incondensible gases in the condensation vessel starts to be dissolved in water, signals are sent from the temperature sensor to a control device and a control valve is opened. With such a constitution, CRD driving water flows into the condensation vessel, and water in which gases at the upper portion of the condensation vessel is dissolved flows into the pressure vessel by way of a pipeline. Then, gases dissolved in a reference water column in the reference leg pipeline are eliminated and the value of a reference water pressure does not change even upon abrupt lowering of pressure. (I.N.)

  14. Review on microfluidic paper-based analytical devices towards commercialisation.

    Science.gov (United States)

    Akyazi, Tugce; Basabe-Desmonts, Lourdes; Benito-Lopez, Fernando

    2018-02-25

    Paper-based analytical devices introduce an innovative platform technology for fluid handling and analysis, with wide range of applications, promoting low cost, ease of fabrication/operation and equipment independence. This review gives a general overview on the fabrication techniques reported to date, revealing and discussing their weak points as well as the newest approaches in order to overtake current mass production limitations and therefore commercialisation. Moreover, this review aims especially to highlight novel technologies appearing in literature for the effective handling and controlling of fluids. The lack of flow control is the main problem of paper-based analytical devices, which generates obstacles for marketing and slows down the transition of paper devices from the laboratory into the consumers' hands. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Management of water leaks on Tore Supra actively cooled fusion device

    International Nuclear Information System (INIS)

    Hatchressian, J.C.; Gargiulo, L.; Samaille, F.; Soler, B.

    2005-01-01

    Up to now, Tore Supra is the only fusion device fully equipped with actively cooled Plasma Facing Components (PFCs). In case of abnormal events during a plasma discharge, the PFCs could be submitted to a transient high power density (run away electrons) or to a continuous phenomena as local thermal flux induced by trapped suprathermal electrons or ions). It could lead to a degradation of the PFC integrity and in the worst case to a water leak occurrence. Such water leak has important consequence on the tokamak operation that concerns PFCs themselves, monitoring equipment located in the vacuum vessel or connected to the ports as RF antennas, diagnostics or pumping systems. Following successive water leak events (the most important water leak, that occurred in September 2002, is described in the paper), a large feedback experience has been gained on Tore supra since more than 15 years that could be useful to actively cooled next devices as W7X and ITER. (authors)

  16. Solution of the problems for electromagnetic compatibility in the data acquisition system on the TM-4A device

    International Nuclear Information System (INIS)

    Zasenko, V.A.; Ivkin, V.G.; Trifonov, E.E.

    1984-01-01

    Solution of the problem of electromagnetic compatibility (EMC) in the system of data acquisition for the TM-4A device has a number of peculiarities. The experience in the adjustment and performance of the device permitted to evaluate the significance of the solutions made. It is shown, that protection of recording complex from pulse background noise of general type, appearing at the moment of commutation of powerful energy storages in the power supply system is the main task of EMC ensurance at the tokamak-type devices. At that, it is necessary to take into account all possible ways of background noise propagation, taking protective measures against each of them. The earthing of electronic equipment by the system of protective earthing or power equipment is not a protective measure against background noise, quite the contrary. In devices, operating in a cycle mode the method of gating is the effective means of protection against background noise. The method realization requires works at the early stage of designing

  17. Location tracking forensics on mobile devices

    Science.gov (United States)

    Sack, Stefan; Kröger, Knut; Creutzburg, Reiner

    2013-03-01

    The spread of navigation devices has increased significantly over the last 10 years. With the help of the current development of even smaller navigation receiver units it is to navigate with almost any current smart phone. Modern navigation systems are no longer limited to satellite navigation, but use current techniques, e.g. WLAN localization. Due to the increased use of navigation devices their relevance to forensic investigations has risen rapidly. Because navigation, for example with navigation equipment and smartphones, have become common place these days, also the amount of saved navigation data has risen rapidly. All of these developments lead to a necessary forensic analysis of these devices. However, there are very few current procedures for investigating of navigation devices. Navigation data is forensically interesting because by the position of the devices in most cases the location and the traveled path of the owner can be reconstructed. In this work practices for forensic analysis of navigation devices are developed. Different devices will be analyzed and it is attempted, by means of forensic procedures to restore the traveled path of the mobile device. For analysis of the various devices different software and hardware is used. There will be presented common procedures for securing and testing of mobile devices. Further there will be represented the specials in the investigation of each device. The different classes considered are GPS handhelds, mobile navigation devices and smartphones. It will be attempted, wherever possible, to read all data of the device. The aim is to restore complete histories of the navigation data and to forensically study and analyze these data. This is realized by the usage of current forensic software e.g. TomTology or Oxygen Forensic Suite. It is also attempted to use free software whenever possible. Further alternative methods are used (e.g. rooting) to access locked data of the unit. To limit the practical work the

  18. Effect of an interactive cardiopulmonary resuscitation assist device with an automated external defibrillator synchronised with a ventilator on the CPR performance of emergency medical service staff: a randomised simulation study.

    Science.gov (United States)

    Nitzschke, Rainer; Doehn, Christoph; Kersten, Jan F; Blanz, Julian; Kalwa, Tobias J; Scotti, Norman A; Kubitz, Jens C

    2017-04-04

    The present study evaluates whether the quality of advanced cardiac life support (ALS) is improved with an interactive prototype assist device. This device consists of an automated external defibrillator linked to a ventilator and provides synchronised visual and acoustic instructions for guidance through the ALS algorithm and assistance for face-mask ventilations. We compared the cardiopulmonary resuscitation (CPR) quality of emergency medical system (EMS) staff members using the study device or standard equipment in a mannequin simulation study with a prospective, controlled, randomised cross-over study design. Main outcome was the effect of the study device compared to the standard equipment and the effect of the number of prior ALS trainings of the EMS staff on the CPR quality. Data were analysed using analyses of covariance (ANCOVA) and binary logistic regression, accounting for the study design. In 106 simulations of 56 two-person rescuer teams, the mean hands-off time was 24.5% with study equipment and 23.5% with standard equipment (Difference 1.0% (95% CI: -0.4 to 2.5%); p = 0.156). With both types of equipment, the hands-off time decreased with an increasing cumulative number of previous CPR trainings (p = 0.042). The study equipment reduced the mean time until administration of adrenaline (epinephrine) by 23 s (p = 0.003) and that of amiodarone by 17 s (p = 0.016). It also increased the mean number of changes in the person doing chest compressions (0.6 per simulation; p < 0.001) and decreased the mean number of chest compressions (2.8 per minute; p = 0.022) and the mean number of ventilations (1.8 per minute; p < 0.001). The chance of administering amiodarone at the appropriate time was higher, with an odds ratio of 4.15, with the use of the study equipment CPR.com compared to the standard equipment (p = 0.004). With an increasing number of prior CPR trainings, the time intervals in the ALS algorithm until the

  19. Integrated logistics management system for operation of machinery and equipment

    Directory of Open Access Journals (Sweden)

    Józef Frąś

    2014-09-01

    concept of integrated logistics management of operation for the stationary transport equipment system. Specific conditions relating to the operation of these devices have been identified. This is essential prerequisites for the development of the concept of the computer solution. The article presents the concepts of the inclusive servicing of warehouse management and cost accounting records and maintenance. Comprehensive integration of these aspects creates a new opportunities in logistics in the field of the operation for stationary transport equipment. This way of design, implementation and recording of maintenance work supported by the integrated management system is a modern tool for conducting maintenance. It's should be mentioned that this conception remains in competition with traditional servicing operators servicing.

  20. Nonimmune cells equipped with T-cell-receptor-like signaling for cancer cell ablation.

    Science.gov (United States)

    Kojima, Ryosuke; Scheller, Leo; Fussenegger, Martin

    2018-01-01

    The ability to engineer custom cell-contact-sensing output devices into human nonimmune cells would be useful for extending the applicability of cell-based cancer therapies and for avoiding risks associated with engineered immune cells. Here we have developed a new class of synthetic T-cell receptor-like signal-transduction device that functions efficiently in human nonimmune cells and triggers release of output molecules specifically upon sensing contact with a target cell. This device employs an interleukin signaling cascade, whose OFF/ON switching is controlled by biophysical segregation of a transmembrane signal-inhibitory protein from the sensor cell-target cell interface. We further show that designer nonimmune cells equipped with this device driving expression of a membrane-penetrator/prodrug-activating enzyme construct could specifically kill target cells in the presence of the prodrug, indicating its potential usefulness for target-cell-specific, cell-based enzyme-prodrug cancer therapy. Our study also contributes to the advancement of synthetic biology by extending available design principles to transmit extracellular information to cells.

  1. Measuring ionizing radiation with a mobile device

    Science.gov (United States)

    Michelsburg, Matthias; Fehrenbach, Thomas; Puente León, Fernando

    2012-02-01

    In cases of nuclear disasters it is desirable to know one's personal exposure to radioactivity and the related health risk. Usually, Geiger-Mueller tubes are used to assess the situation. Equipping everyone with such a device in a short period of time is very expensive. We propose a method to detect ionizing radiation using the integrated camera of a mobile consumer device, e.g., a cell phone. In emergency cases, millions of existing mobile devices could then be used to monitor the exposure of its owners. In combination with internet access and GPS, measured data can be collected by a central server to get an overview of the situation. During a measurement, the CMOS sensor of a mobile device is shielded from surrounding light by an attachment in front of the lens or an internal shutter. The high-energy radiation produces free electrons on the sensor chip resulting in an image signal. By image analysis by means of the mobile device, signal components due to incident ionizing radiation are separated from the sensor noise. With radioactive sources present significant increases in detected pixels can be seen. Furthermore, the cell phone application can make a preliminary estimate on the collected dose of an individual and the associated health risks.

  2. 29 CFR 97.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  3. 44 CFR 13.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  4. 24 CFR 85.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  5. 43 CFR 12.72 - Equipment.

    Science.gov (United States)

    2010-10-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  6. A device for automatically recording information on the reasons for idling of stopes

    Energy Technology Data Exchange (ETDEWEB)

    Dergachev, L G; Kuzoyatov, G I; Tereshchenko, V N

    1979-01-01

    One substantial reserve for raising production efficiency in the coal industry is reduction of nonproductive time costs. The state of the art of stoping work and design features of stoping equipment and devices for obtaining information do not presently enable complete automation of the process of obtaining data on the reasons for down times. Therefore, together with automatic data formation manual recording of information is required through remote control equipment to the controlling computer directly from the work place. The Donetsk department of the Giprougleavtomatizatsiy institute has developed the UKIP-1 device for automatic recording of information on the reasons for stope down times. The device is designed for use in an automatic process control system of coal mines. It provides coding of information and its conversion to a form suitable for transmission through remote control channels, further processing, and recording. The device enables recording of information on down times of eight objects of the stope. Up to eight down time reasons can be recorded for each object. The device has 2 contact outputs, on one of which is formed an informational sequential eight-bit code; on the other, 8 clock pulses. The device's code is generated automatically, after it is activated by a switch. The length of the code packet results from the maximum possible information transmission rate of the existing mine remote control systems, and equals 12+2 sec. The clock pulse length equals half the length of the information pulse. The device has been tested at coal mines, and recommended for industrial production. UKIP-1 devices are being used in a pilot model of an automatic production control system of the Sotsialisticheskiy Donbass Newspaper mine of the Donetskugol' production association.

  7. A new portable device for automatic controlled-gradient cryopreservation of blood mononuclear cells.

    Science.gov (United States)

    Hviid, L; Albeck, G; Hansen, B; Theander, T G; Talbot, A

    1993-01-04

    Protection of the functional integrity of mononuclear cells stored in liquid N2 requires careful control of the freezing procedure. Consequently, optimal quality of cryopreserved cells is usually assured by freezing according to a specified time-temperature gradient generated by computer-controlled freezing devices. While such equipment offers large capacity and secures maximum survival and functional integrity of the lymphocytes upon thawing, it is quite costly and strictly stationary. We have previously developed and tested an alternative, manual device for controlled-gradient lymphocyte freezing, which has proved suitable for field conditions. We report here the development and testing of a similar micro-controller regulated device, allowing unattended and automatic controlled-gradient cell freezing. The equipment exploits the temperature gradient present between the liquid N2 surface and the neck in an ordinary liquid N2 refrigerator. The lymphocyte samples are placed in a small elevator, which is moved through the N2 gas phase by a stepper motor. Time and temperature are measured at regular intervals, and the position of the samples adjusted to ensure that the actual measurements closely match encoded ideal values. Results of assays of the functional integrity and phenotypic composition of human mononuclear cells frozen by the new system were comparable to those obtained when using cells frozen by a commercially available, stationary cell-freezing equipment, or fresh autologous cell samples tested in parallel. Furthermore, there was a good correlation between functional and phenotypic data obtained using frozen and autologous fresh samples of mononuclear cells. The equipment described is low weight and has low N2 consumption, and is thus suitable for the collection and cryopreservation of lymphocytes under field conditions. Furthermore, the technique provides an inexpensive alternative for researchers with a limited requirement for the simultaneous freezing of

  8. Research on application of mobile diesel equipment in underground mines 2

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bok Youn; Kang, Chang Hee; Jo, Young Do; Lim, Sang Taek [Korea Inst. of Geology Mining and Materials, Taejon (Korea, Republic of)

    1995-12-01

    It is 2 nd year of the research project on application of mobile diesel equipment in underground mines for providing appropriate measures to improve underground working environment contaminated by the diesel exhaust pollutants. Studies on Diesel Particulate Matter(DPM), which is regarded as a carcinogenic substances, was carried out intensively to figure out which substance is the most critical one among the diesel exhaust pollutants. The production mechanism and health effects of DPM, and evaluation of hazard level of underground workings was conducted. For development of exhaust treatment devices and recommendation of the best concept suitable for local conditions has been done. And the basic guidelines for good engine maintenance to provide the safe and healthful use of diesel-powered mine equipment were suggested so that field engineers can use it as a reference in daily operations. (author). 19 refs., 31 figs., 41 tabs.

  9. Channel Access and Power Control for Mobile Crowdsourcing in Device-to-Device Underlaid Cellular Networks

    Directory of Open Access Journals (Sweden)

    Yue Ma

    2018-01-01

    Full Text Available With the access of a myriad of smart handheld devices in cellular networks, mobile crowdsourcing becomes increasingly popular, which can leverage omnipresent mobile devices to promote the complicated crowdsourcing tasks. Device-to-device (D2D communication is highly desired in mobile crowdsourcing when cellular communications are costly. The D2D cellular network is more preferable for mobile crowdsourcing than conventional cellular network. Therefore, this paper addresses the channel access and power control problem in the D2D underlaid cellular networks. We propose a novel semidistributed network-assisted power and a channel access control scheme for D2D user equipment (DUE pieces. It can control the interference from DUE pieces to the cellular user accurately and has low information feedback overhead. For the proposed scheme, the stochastic geometry tool is employed and analytic expressions are derived for the coverage probabilities of both the cellular link and D2D links. We analyze the impact of key system parameters on the proposed scheme. The Pareto optimal access threshold maximizing the total area spectral efficiency is obtained. Unlike the existing works, the performances of the cellular link and D2D links are both considered. Simulation results show that the proposed method can improve the total area spectral efficiency significantly compared to existing schemes.

  10. Auditing of Monitoring and Respiratory Support Equipment in a Level III-C Neonatal Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Elena Bergon-Sendin

    2015-01-01

    Full Text Available Background. Random safety audits (RSAs are a safety tool but have not been widely used in hospitals. Objectives. To determine the frequency of proper use of equipment safety mechanisms in relation to monitoring and mechanical ventilation by performing RSAs. The study also determined whether factors related to the patient, time period, or characteristics of the area of admission influenced how the device safety systems were used. Methods. A prospective observational study was conducted in a level III-C Neonatal Intensive Care Unit (NICU during 2012. 87 days were randomly selected. Appropriate overall use was defined when all evaluated variables were correctly programmed in the audited device. Results. A total of 383 monitor and ventilator audits were performed. The Kappa coefficient of interobserver agreement was 0.93. The rate of appropriate overall use of the monitors and respiratory support equipment was 33.68%. Significant differences were found with improved usage during weekends, OR 1.85 (1.12–3.06, p=0.01, and during the late shift (3 pm to 10 pm, OR 1.59 (1.03–2.4, p=0.03. Conclusions. Equipment safety systems of monitors and ventilators are not properly used. To improve patient safety, we should identify which alarms are really needed and where the difficulties lie for the correct alarm programming.

  11. Establishment for Nuclear Equipment: Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2000-01-01

    Full text: The main objective of the activity of the Establishment for Nuclear Equipment (ZdAJ) in 1999 was to obtain the ISO 9001 certificate. Work on this problem has been successfully completed. The changes introduced in agreement with requirements of ISO in supervising the construction, manufacturing and servicing eliminate possible deficiencies of our products and will pay in the future. Two new important ventures have been undertaken: design of an accelerator with two photon energies and a reconstruction of simulator directed towards better geometrical parameters. The completion of the improvements in accelerator is foreseen for the year 2002. The changes comprise almost all sub-assemblies of the device. The modernized simulator will be installed in the hospital already in the year 2000 - the ameliorations concern mainly the arm of the apparatus, collimator, driving gears and control system. Of course - apart from this, the routine production activity of the Establishment was continued in 1999. (author)

  12. Design and construction of engineering test device of a multi-purpose radwaste incineration system

    International Nuclear Information System (INIS)

    Wang Peiyi; Zhou Lianquan; Ma Mingxie; Qiu Mingcai; Yang Liguo; Li Xiaohai; Zhang Xiaobin; Lu Xiaowu; Dong Jingling; Wang Xujin; Li Chuanlian; Yang Baomin

    2002-01-01

    The author describes designs of main un-standard devices, monitoring system and safety system, as well as construction of the engineering system devices for a multi-purpose radwaste incineration system. Un-standard devices include waste crusher, pyrolysis furnace, incinerator furnace, cool stream dilution device and bag filter, etc. The monitoring system mainly includes industrial controlled computer, supported by conventional electrical equipment and instruments. Designs of system safety takes account of containment of radioactive materials fire-prevention, explosion prevention, anti-corrosion, redundance and reservation, emergency system, controlling and electric safety system, etc. Results show that main technological system remains good airtight with leakage ratio at 0.67%

  13. Harmonics in power systems of ships with electrical propulsion drives. Effects on the equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M [VTT Energy, Espoo (Finland). Energy Systems

    1996-11-01

    In this report the effect of harmonics on the power system equipment and loads, with special attention given to the circumstances in ships, is discussed. Some guidelines are given for the computation of additional harmonic losses in power cables and transformers. It is also shown, that if the system is rich in harmonics, these losses must be taken into account when sizing the equipment. The effect of harmonics on electrical machines is also discussed. The influence on induction machines is usually small. However, in large synchronous machines a significant degree of harmonic losses may be expected. Especially in the high voltage system the harmonics must be taken into account when selecting the machine ratings. Also the harmonic resonances, which may arise when using reactive power compensation capacitors, are discussed. Due to the risk of harmonic resonances, the use of capacitors is not recommended in marine power systems. Also the immunity of different load devices to harmonic distortion is discussed. The equipment considered are resistive loads, discharge lamps, universal machines and electronic equipment. Finally a brief survey is given on the standards and recommendations for the maximum distortion levels allowed. (author)

  14. Primary Salvage Survey of the Interference of Radiowaves Emitted by Smartphones on Medical Equipment.

    Science.gov (United States)

    Takao, Hiroyuki; Yeh, Yu Chih; Arita, Hiroyuki; Obatake, Takumi; Sakano, Teppei; Kurihara, Minoru; Matsuki, Akira; Ishibashi, Toshihiro; Murayama, Yuichi

    2016-10-01

    Use of mobile phones has become a standard reality of everyday living for many people worldwide, including medical professionals, as data sharing has drastically helped to improve quality of care. This increase in the use of mobile phones within hospitals and medical facilities has raised concern regarding the influence of radio waves on medical equipment. Although comprehensive studies have examined the effects of electromagnetic interference from 2G wireless communication and personal digital cellular systems on medical equipment, similar studies on more recent wireless technologies such as Long Term Evolution, wideband code division multiple access, and high-speed uplink access have yet to be published. Numerous tests targeting current wireless technologies were conducted between December 2012 and March 2013 in an anechoic chamber, shielded from external radio signals, with a dipole antenna to assess the effects of smartphone interference on several types of medical equipment. The interference produced by electromagnetic waves across five frequency bands from four telecommunication standards was assessed on 49 components from 22 pieces of medical equipment. Of the 22 pieces of medical equipment tested, 13 experienced interference at maximum transmission power. In contrast, at minimum transmission power, the maximum interference distance varied from 2 to 5 cm for different wireless devices. Four machines were affected at the minimum transmission power, and the maximum interference distance at the maximum transmission power was 38 cm. Results show that the interference from smartphones on medical equipment is very controllable.

  15. EMI environment EMC considerations concerning equipment upgrades at a nuclear utility power generating station a case history

    International Nuclear Information System (INIS)

    Metcalf, M.J.

    1993-01-01

    As equipment is upgraded during scheduled power outages in nuclear power generating stations, more and more utilities will be faced with the problem of dealing with Electromagnetic Compatibility (EMC) issues that have evolved with the trend of manufacturers designing equipment based around state-of-the-art high technology logic devices. This paper lists Commonwealth Edison Company (CECO) equipment that was scrutinized by National Technical Systems (NTS) for its EMI impact. The test requirements and test procedures for assessing EMI and EMC are outlined. Although on-site mapping data was gathered to assist CECO for the upgrade described here of the Auxiliary Electric Equipment Room of a Westinghouse Eagle 21 Reactor Protection System at the Zion Unit No.1 Station, blanket mapping of every location for every upgrade is a short term, expensive solution to the EMI problem. It is concluded that the primary problem of lack of system and component level EMI specifications must be addressed by a governing body. 7 refs., 2 figs

  16. Design and Application of Automatic Falling Device for Different Brands of Goods

    Science.gov (United States)

    Yang, Xudong; Ge, Qingkuan; Zuo, Ping; Peng, Tao; Dong, Weifu

    2017-12-01

    The Goods-Falling device is an important device in the intelligent sorting goods sorting system, which is responsible for the temporary storage and counting of the goods, and the function of putting the goods on the conveyor belt according to certain precision requirements. According to the present situation analysis and actual demand of the domestic goods sorting equipment, a vertical type Goods - Falling Device is designed and the simulation model of the device is established. The dynamic characteristics such as the angular error of the opening and closing mechanism are carried out by ADAMS software. The simulation results show that the maximum angular error is 0.016rad. Through the test of the device, the goods falling speed is 7031/hour, the good of the falling position error within 2mm, meet the crawl accuracy requirements of the palletizing robot.

  17. Microwave produced plasma in a Toroidal Device

    Science.gov (United States)

    Singh, A. K.; Edwards, W. F.; Held, E. D.

    2010-11-01

    A currentless toroidal plasma device exhibits a large range of interesting basic plasma physics phenomena. Such a device is not in equilibrium in a strict magneto hydrodynamic sense. There are many sources of free energy in the form of gradients in plasma density, temperature, the background magnetic field and the curvature of the magnetic field. These free energy sources excite waves and instabilities which have been the focus of studies in several devices in last two decades. A full understanding of these simple plasmas is far from complete. At Utah State University we have recently designed and installed a microwave plasma generation system on a small tokamak borrowed from the University of Saskatchewan, Saskatoon, Canada. Microwaves are generated at 2.45 GHz in a pulsed dc mode using a magnetron from a commercial kitchen microwave oven. The device is equipped with horizontal and vertical magnetic fields and a transformer to impose a toroidal electric field for current drive. Plasmas can be obtained over a wide range of pressure with and without magnetic fields. We present some preliminary measurements of plasma density and potential profiles. Measurements of plasma temperature at different operating conditions are also presented.

  18. Medical devices for the anesthetist: current perspectives

    Directory of Open Access Journals (Sweden)

    Ingrande J

    2014-03-01

    Full Text Available Jerry Ingrande, Hendrikus JM LemmensDepartment of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, CA, USAAbstract: Anesthesiologists are unique among most physicians in that they routinely use technology and medical devices to carry out their daily activities. Recently, there have been significant advances in medical technology. These advances have increased the number and utility of medical devices available to the anesthesiologist. There is little doubt that these new tools have improved the practice of anesthesia. Monitoring has become more comprehensive and less invasive, airway management has become easier, and placement of central venous catheters and regional nerve blockade has become faster and safer. This review focuses on key medical devices such as cardiovascular monitors, airway equipment, neuromonitoring tools, ultrasound, and target controlled drug delivery software and hardware. This review demonstrates how advances in these areas have improved the safety and efficacy of anesthesia and facilitate its administration. When applicable, indications and contraindications to the use of these novel devices will be explored as well as the controversies surrounding their use.Keywords: catheters, echocardiography, ultrasound, fiberoptic bronchoscope, laryngeal mask airway, closed-loop anesthesia

  19. 14 CFR 141.41 - Flight simulators, flight training devices, and training aids.

    Science.gov (United States)

    2010-01-01

    ..., and training aids. 141.41 Section 141.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... aids. An applicant for a pilot school certificate or a provisional pilot school certificate must show that its flight simulators, flight training devices, training aids, and equipment meet the following...

  20. Suitability of electrolyzed oxidizing water for the disinfection of hard surfaces and equipment in radiology.

    Science.gov (United States)

    Pintaric, Robert; Matela, Joze; Pintaric, Stefan

    2015-01-01

    Hospitals are faced with increasingly resistant strains of micro-organisms. When it comes to disinfection, individual parts of electronic equipment of angiology diagnostics such as patient couches of computer tomography (CT) and magnetic resonance imaging (MRI) scanners prove to be very hard to disinfect. Disinfectants of choice are therefore expected to possess properties such as rapid, residue-free action without any damaging effect on the sensitive electronic equipment. This paper discusses the use of the neutral electrolyzed oxidizing water (EOW) as a biocide for the disinfection of diagnostic rooms and equipment. The CT and MRI rooms were aerosolized with EOW using aerosolization device. The presence of micro-organisms before and after the aerosolization was recorded with the help of sedimentation and cyclone air sampling. Total body count (TBC) was evaluated in absolute and log values. The number of micro-organisms in hospital rooms was low as expected. Nevertheless, a possible TBC reduction between 78.99-92.50% or 50.50-70.60% in log values was recorded. The research has shown that the use of EOW for the air and hard surface disinfection can considerably reduce the presence of micro-organisms and consequently the possibility of hospital infections. It has also demonstrated that the sedimentation procedure is insufficient for the TBC determination. The use of Biocide aerosolization proved to be efficient and safe in all applied ways. Also, no eventual damage to exposed devices or staff was recorded.

  1. Surge protective device response to steep front transient in low voltage circuit

    Energy Technology Data Exchange (ETDEWEB)

    Marcuz, J.; Binczak, S.; Bilbault, J.M. [Universite de Bourgogne, Dijon (France)], Emails: jerome.marcuz@ laposte.net, stbinc@u-bourgogne.fr, bilbault@u-bourgogne.fr; Girard, F. [ADEE Electronic, Pont de Pany (France)

    2007-07-01

    Surge propagation on cables of electrical or data lines leads to a major protection problem as the number of equipment based on solid-state circuits or microprocessors increases. Sub-microsecond components of real surge waveform has to be taken into account for a proper protection even in the case of surges caused by indirect lightning effects. The response of a model of transient voltage suppressor diode based surge protection device (SPD) to fast front transient is analytically studied, then compared to simulations, including the lines connected to the SPD and to the protected equipment. (author)

  2. Radiation hardness and qualification of semiconductor electronic devices for nuclear reactors

    International Nuclear Information System (INIS)

    Friant, A.; Payat, R.

    1984-05-01

    After a brief review of radiation effects in semiconductors and radiation damage in semiconductor devices, the problems of qualification of electronic equipment to be used in nuclear reactors are compared to those relative to nuclear weapons or space experiments. The conclusion is that data obtained at very high dose rates or under pulsed irradiation in weapons and space programs should not be directly applied to nuclear plant instrumentation. The need for a specific qualification of semiconductor devices appropriate for nuclear reactors is emphasized. Some irradiation studies at IRDI/DEIN (CEN-Saclay) are related [fr

  3. Approval of devices and facilities using ionizing radiations for medical purposes

    International Nuclear Information System (INIS)

    1977-01-01

    This Order made by the Ministers of Health and Social Security, Agriculture and Labour amends a previous Decree of 23 April 1969 in particular concerning the classification of medical or dental radiodiagnostic devices subject to approval. The technical conditions to be complied with for such devices and facilities have also been amended. Finally, it is provided that, as regards facilities with heavy equipment subject to licensing (Act of 31 December 1970), approval is subject to compliance with the licensing conditions and is requested together with the application for a licence. (NEA) [fr

  4. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  5. Decontamination chamber for the maintenance of DUPIC nuclear fuel fabrication and process equipment

    International Nuclear Information System (INIS)

    Kim, K. H.; Park, J. J.; Yang, M. S.; Lee, H. H.; Shin, J. M.

    2000-10-01

    This report presents the decontamination chamber of being capable of decontaminating and maintaining DUPIC nuclear fuel fabrication equipment contaminated in use. The decontamination chamber is a closed room in which contaminated equipment can be isolated from a hot-cell, be decontaminated and be reparired. This chamber can prevent contamination from spreading over the hot-cell, and it can also be utilized as a part of the hot-cell after maintenance work. The developed decontamination chamber has mainly five sub-modules - a horizontal module for opening and closing a ceil of the chamber, a vertical module for opening and closing a side of the chamber, a subsidiary door module for enforcing the vertical opening/closing module, a rotary module for rotating contaminated equipment, and a grasping module for holding a decontamination device. Such sub-modules were integrated and installed in the M6 hot-cell of the IMEF at the KAERI. The mechanical design considerations of each modules and the arrangement with hot-cell facility, remote operation and manipulation of the decontamination chamber are also described

  6. Decontamination chamber for the maintenance of DUPIC nuclear fuel fabrication and process equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K. H.; Park, J. J.; Yang, M. S.; Lee, H. H.; Shin, J. M

    2000-10-01

    This report presents the decontamination chamber of being capable of decontaminating and maintaining DUPIC nuclear fuel fabrication equipment contaminated in use. The decontamination chamber is a closed room in which contaminated equipment can be isolated from a hot-cell, be decontaminated and be reparired. This chamber can prevent contamination from spreading over the hot-cell, and it can also be utilized as a part of the hot-cell after maintenance work. The developed decontamination chamber has mainly five sub-modules - a horizontal module for opening and closing a ceil of the chamber, a vertical module for opening and closing a side of the chamber, a subsidiary door module for enforcing the vertical opening/closing module, a rotary module for rotating contaminated equipment, and a grasping module for holding a decontamination device. Such sub-modules were integrated and installed in the M6 hot-cell of the IMEF at the KAERI. The mechanical design considerations of each modules and the arrangement with hot-cell facility, remote operation and manipulation of the decontamination chamber are also described.

  7. On the effect of the near field records on the steel braced frames equipped with energy dissipating devices

    Directory of Open Access Journals (Sweden)

    Mahmoud Bayat

    Full Text Available The behavior of braced steel frame structures is of special importance due to its extensive use. Also the application of active and semi-active control systems, regarding to their benefits in obtaining better seismic performance has increased significantly. The majority of the works on steel structures and steel connections has been done under far field records, and the behavior of steel frame structures equipped with yielding dampers under these circumstances has not yet been fully analyzed. The main purpose of this paper is to determine the behavior of structures equipped with yielding dampers, located in near field based on energy concepts. In order to optimize their seismic behavior, the codes and solutions are also presented.The selected system is a braced steel frame system which is equipped with yielding dampers and the analysis is performed using the "Perform 3D V.4" software and the conclusions are drawn upon energy criterion. The effect of PGA variation and height of the frames are also considered in the study .Finally, using the above mentioned results, a proper solution is presented for typical systems in order to increase the energy damping ability and reduce the destructive effects in structures on an earthquake event, so that a great amount of induced energy is damped and destruction of the structure is prevented as much as possible.

  8. Managing medical equipment used by technology-dependent children: evaluation of an instructional tool for pediatric residents and medical students.

    Science.gov (United States)

    Jackson, Jennifer M; Radulovic, Andrea; Nageswaran, Savithri

    2012-08-01

    To evaluate the effectiveness of a workshop on managing medical devices used in technology-dependent children. Study participants included residents and medical students rotating in the pediatrics department at the time of the study. A workshop was conducted consisting of learning stations for common medical devices, including brief presentations and opportunities for hands-on practice with each device. Participants completed surveys before and after the workshop assessing their perceived ability to manage medical equipment before and after the workshop and their ongoing learning needs. All participants indicated a substantial need for training on how to manage medical devices used by technology-dependent patients. Scores for perceived ability to manage the devices improved significantly after workshop participation for nearly all devices taught. Medical trainees have significant learning needs for managing devices used by technology-dependent patients. Hands-on, small-group training can be an effective instructional tool for improving confidence in these skills.

  9. MODELING OF POWER SYSTEMS AND TESTING OF RELAY PROTECTION DEVICES IN REAL AND MODEL TIME

    Directory of Open Access Journals (Sweden)

    I. V. Novash

    2017-01-01

    Full Text Available The methods of modelling of power system modes and of testing of relay protection devices with the aid the simulation complexes in real time and with the help of computer software systems that enables the simulation of virtual time scale are considered. Information input protection signals in the simulation of the virtual model time are being obtained in the computational experiment, whereas the tests of protective devices are carried out with the help of hardware and software test systems with the use of estimated input signals. Study of power system stability when modes of generating and consuming electrical equipment and conditions of devices of relay protection are being changed requires testing with the use of digital simulators in a mode of a closed loop. Herewith feedbacks between a model of the power system operating in a real time and external devices or their models must be determined (modelled. Modelling in real time and the analysis of international experience in the use of digital simulation power systems for real-time simulation (RTDS simulator have been fulfilled. Examples are given of the use of RTDS systems by foreign energy companies to test relay protection systems and control, to test the equipment and devices of automatic control, analysis of cyber security and evaluation of the operation of energy systems under different scenarios of occurrence of emergency situations. Some quantitative data on the distribution of RTDS in different countries and Russia are presented. It is noted that the leading energy universities of Russia use the real-time simulation not only to solve scientific and technical problems, but also to conduct training and laboratory classes on modelling of electric networks and anti-emergency automatic equipment with the students. In order to check serviceability of devices of relay protection without taking into account the reaction of the power system tests can be performed in an open loop mode with the

  10. Stakeholder challenges in purchasing medical devices for patient safety.

    Science.gov (United States)

    Hinrichs, Saba; Dickerson, Terry; Clarkson, John

    2013-03-01

    This study identifies the stakeholders who have a role in medical device purchasing within the wider system of health-care delivery and reports on their particular challenges to promote patient safety during purchasing decisions. Data was collected through observational work, participatory workshops, and semi-structured qualitative interviews, which were analyzed and coded. The study takes a systems-based and engineering design approach to the study. Five hospitals took part in this study, and the participants included maintenance, training, clinical end-users, finance, and risk departments. The main stakeholders for purchasing were identified to be staff from clinical engineering (Maintenance), device users (Clinical), device trainers (Training), and clinical governance for analyzing incidents involving devices (Risk). These stakeholders display varied characteristics in terms of interpretation of their own roles, competencies for selecting devices, awareness and use of resources for purchasing devices, and attitudes toward the purchasing process. The role of "clinical engineering" is seen by these stakeholders to be critical in mediating between training, technical, and financial stakeholders but not always recognized in practice. The findings show that many device purchasing decisions are tackled in isolation, which is not optimal for decisions requiring knowledge that is currently distributed among different people within different departments. The challenges expressed relate to the wider system of care and equipment management, calling for a more systemic view of purchasing for medical devices.

  11. Influence of pulse electromagnetic fields on electronic equipment and systems in smart buildings

    Directory of Open Access Journals (Sweden)

    Jacek Paś

    2016-07-01

    Full Text Available The article presents information about the impact of electromagnetic fields’ impulses on technical infrastructure of electronic equipment and systems in intelligent buildings. The use of modern technical solutions in intelligent building management, i.e., human resources control and automation systems, efficient building space management, requires a large number of integrated electronic systems. Impulse interference, lightning or electricity as natural phenomena are among the most responsible for the occurrence of interference in buses, transmission lines systems, electrical installations, equipment and electronic systems used in intelligent buildings. To a large extent, it is associated with catastrophic damages that may occur in electronic devices or in completed systems such as intelligent building, e.g. ICT, security, etc. under the influence of induced voltages and interfering signals’ currents. Keywords: noise, static electricity, lightning

  12. Device for measuring well twistings

    Energy Technology Data Exchange (ETDEWEB)

    Kostin, Yu S; Golubin, S V; Keller, V F; Merzheyevskiy, A B; Zdorov, V P

    1982-01-01

    The device for measuring the well twistings with the use of fluids (poured into a vessel and which leave an imprint on the walls), containing a housing and adapter, is distinguished by the fact that in order to improve the accuracy of measurement by obtaining a clear imprint, it is equipped with cylinder that is spring-loaded in relation to the adapter, forming a vessel for fluid with the adapter. The adapter is made of two parts, one of which is made of neutral metal in relation to the fluid, and the other, from active in relation to the same fluid.

  13. Development and Application of the Downhole Drilling String Shock-Absorption and Hydraulic Supercharging Device

    Directory of Open Access Journals (Sweden)

    Yongwang Liu

    2016-01-01

    Full Text Available It is a hot topic for deep/ultradeep wells to improve rock-breaking efficiency and drilling speed by available downhole energy. Based on different downhole energies and working conditions, specialized plunger pump is proposed to convert longitudinal vibration of drilling string into rock-breaking energy. Technical design is developed to generate high-pressure water jet. And then a simulation model is built to verify feasibility of the technical design. Through simulation, the influence law of key factors is obtained. On this basis, this device is tested in several wells. The result indicates this device can increase drilling speed as much as 136%. Meanwhile the harmful vibration can be absorbed. The energy from drilling string vibration is of high frequency and increases as well depth and formation anisotropy increase. By reducing adverse vibration, this device is able to increase the drilling speed and the service life also meets the demand of field application. The longest working time lasts for more than 130 hours. The performance of this device demonstrates great application prospect in deep/ultradeep resources exploration. To provide more equipment support for deep/ultradeep wells, more effort should be put into fundamental study on downhole drill string vibration and related equipment.

  14. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    Science.gov (United States)

    Murata, C. H.; Fernandes, D. C.; Lavínia, N. C.; Caldas, L. V. E.; Pires, S. R.; Medeiros, R. B.

    2014-02-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  15. Efficiency Intra-Cluster Device-to-Device Relay Selection for Multicast Services Based on Combinatorial Auction

    Directory of Open Access Journals (Sweden)

    Yong Zhang

    2015-12-01

    Full Text Available In Long Term Evolution-Advanced (LTE-A networks, Device-to-device (D2D communications can be utilized to enhance the performance of multicast services by leveraging D2D relays to serve nodes with worse channel conditions within a cluster. For traditional D2D relay schemes, D2D links with poor channel condition may be the bottleneck of system sum data rate. In this paper, to optimize the throughput of D2D communications, we introduce an iterative combinatorial auction algorithm for efficient D2D relay selection. In combinatorial auctions, the User Equipments (UEs that fails to correctly receive multicast data from eNodeB (eNB are viewed as bidders that compete for D2D relays, while the eNB is treated as the auctioneer. We also give properties of convergency and low-complexity and present numerical simulations to verify the efficiency of the proposed algorithm.

  16. Used energy-related laboratory equipment grant program for institutions of higher learning. Eligible equipment catalog

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This is a listing of energy related equipment available through the Energy-Related Laboratory Equipment Grant Program which grants used equipment to institutions of higher education for energy-related research. Information included is an overview of the program, how to apply for a grant of equipment, eligibility requirements, types of equipment available, and the costs for the institution.

  17. Equipment repair in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, S

    1982-01-01

    Most equipment in Chinese coal mines consists of machinery and equipment produced in the 1950s; the efficiency of 4-62, CTD-57 and 70B/sub 2/ ventilators is 15% lower than that of new ones; that of SSM and AYaP pumps, 10% lower than of modern ones. Equipment renovation is done in three ways: replacing obsolete equipment with new equipment of the same type; improving the performance of existing equipment by introducing efficiency and reconstruction; and replacing obsolete equipment with advanced equipment. It is indicated that the second way, for example, replacement of 4-62 ventilator blades with a maximum efficiency of 73% by 4-72 ventilator blades raises its efficiency to 90%. Replacing the 8DA-8x3 water pump, having a maximum efficiency of 63%, with the 200D 43x3 pump with a maximum efficiency of 78%, enables an electricity savings of 7000 yuan per year, which exceeds all replacement costs (600 yuan). The need to improve equipment maintenance and preventive work to increase equipment service life and to introduce new techniques and efficiency is noted.

  18. An electronic probe micro-analyser. A linear scan device; Microanalyseur a sonde electronique. Dispositif de balayage lineaire

    Energy Technology Data Exchange (ETDEWEB)

    Kirianenko, A; Maurice, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The Castaing electronic probe micro-analyser makes possible static analysis at successive points. For two years this apparatus has been equipped by its constructor with an automatic device for surface scanning. In order to increase the micro-analyser's efficiency a 'linear' scan device has been incorporated making it possible to obtain semi-quantitative analyses very rapidly. (authors) [French] Le microanalyseur a sonde electronique de Castaing permet l'analyse statique en des points successifs. Depuis deux ans, cet appareil a ete equipe par son constructeur d'un dispositif de balayage automatique 'surface'. Afin d'augmenter l'efficacite du microanalyaeur, on a adapte un dispositif de balayage 'lineaire' qui permet d'obtenir tres rapidement des analyses semi-quantitative. (auteurs)

  19. α-spectrometric device equipped with semi-conductors for direct measurement of transuranium elements on large area filters

    International Nuclear Information System (INIS)

    Fessler, H.; Pawelzik, J.

    1984-10-01

    A device was developed with an array of 8 silicon surface barrier detectors inside a vacuum chamber containing a rotating sample holder for large areas (200 mm diameter) aerosol filters. It serves for quick identification of α-emitters on these aerosol filters, and allows to measure the α-particles with a relatively constant efficiency along a filter diameter. Thus, the radiochemical treatment of single filters can be avoided. Troubles appeared in the course of development of defective semiconductors and their temperature dependence. To suppress the influence of temperature a cooling device was built. During practical testing a cross-efficiency of 13.6% was measured. It is possible to identify α-emitting nuclides with an activity of 10 -1 Bq per sample during about 2 hours of measuring time. Appropriate methodes of calculation are indicated. The data output of the device is suited for transfer to a computer. (orig./HP) [de

  20. BP volume reduction equipment

    International Nuclear Information System (INIS)

    Kitamura, Yoshinori; Muroo, Yoji; Hamanaka, Isao

    2003-01-01

    A new type of burnable poison (BP) volume reduction system is currently being developed. Many BP rods, a subcomponent of spent fuel assemblies are discharged from nuclear power reactors. This new system reduces the overall volume of BP rods. The main system consists of BP rod cutting equipment, equipment for the recovery of BP cut pieces, and special transport equipment for the cut rods. The equipment is all operated by hydraulic press cylinders in water to reduce operator exposure to radioactivity. (author)

  1. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  2. 22 CFR 135.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  3. 21 CFR 1403.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  4. 45 CFR 602.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  5. 49 CFR 18.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  6. 34 CFR 80.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  7. 10 CFR 600.232 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  8. 45 CFR 1183.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  9. Stress testing on silicon carbide electronic devices for prognostics and health management.

    Energy Technology Data Exchange (ETDEWEB)

    Kaplar, Robert James; Brock, Reinhard C.; Marinella, Matthew; King, Michael Patrick; Smith, Mark A.; Atcitty, Stanley

    2011-01-01

    Power conversion systems for energy storage and other distributed energy resource applications are among the drivers of the important role that power electronics plays in providing reliable electricity. Wide band gap semiconductors such as silicon carbide (SiC) and gallium nitride (GaN) will help increase the performance and efficiency of power electronic equipment while condition monitoring (CM) and prognostics and health management (PHM) will increase the operational availability of the equipment and thereby make it more cost effective. Voltage and/or temperature stress testing were performed on a number of SiC devices in order to accelerate failure modes and to identify measureable shifts in electrical characteristics which may provide early indication of those failures. Those shifts can be interpreted and modeled to provide prognostic signatures for use in CM and/or PHM. Such experiments will also lead to a deeper understanding of basic device physics and the degradation mechanisms behind failure.

  10. 77 FR 17457 - Work Group on Alternative Test Methods for Commercial Measuring Devices

    Science.gov (United States)

    2012-03-26

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Work Group on Alternative... Work Group (WG) to examine alternative methods for testing the accuracy of commercial measuring devices... participates to promote uniformity among the states in laws, regulations, methods, and testing equipment that...

  11. The development of a ballistic method for simulating fragments from buried explosive devices

    NARCIS (Netherlands)

    Jagt-Deutekom, M.J. van der

    2016-01-01

    No standard scientific methodology currently exists to assess the performance of personal protection equipment (PPE) against secondary debris, such as soil, grit and stones, ejected when a buried improvised explosive device (IED) detonates. Different test methods are used for this evaluation. The

  12. Development of manufacturing equipment and QC equipment for DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Park, J.J.; Lee, J.W.; Kim, S.S.; Yim, S.P.; Kim, J.H.; Kim, K.H.; Na, S.H.; Kim, W.K.; Shin, J.M.; Lee, D.Y.; Cho, K.H.; Lee, Y.S.; Sohn, J.S.; Kim, M.J.

    1999-05-01

    In this study, DUPIC powder and pellet fabrication equipment, welding system, QC equipment, and fission gas treatment are developed to fabricate DUPIC fuel at IMEF M6 hot cell. The systems are improved to be suitable for remote operation and maintenance with the manipulator at hot cell. Powder and pellet fabrication equipment have been recently developed. The systems are under performance test to check remote operation and maintenance. Welding chamber and jigs are designed and developed to remotely weld DUPIC fuel rod with manipulators at hot cell. Remote quality control equipment are being tested for analysis and inspection of DUPIC fuel characteristics at hot cell. And trapping characteristics is analyzed for cesium and ruthenium released under oxidation/reduction and sintering processes. The design criteria and process flow diagram of fission gas treatment system are prepared incorporating the experimental results. The fission gas treatment system has been successfully manufactured. (Author). 33 refs., 14 tabs., 91 figs

  13. Evaluation of safety requirements of erbium laser equipment used in dentistry

    International Nuclear Information System (INIS)

    Braga, Flavio Hamilton

    2002-01-01

    The erbium laser (Er:YAG) has been used in several therapeutic processes. Erbium lasers, however, operate with energies capable to produce lesions in biological tissues. Aiming the safe use, the commercialization of therapeutic laser equipment is controlled in Brazil, where the equipment should comply with quality and safety requirement prescribed in technical regulations. The objective of this work is to evaluate the quality and safety requirements of a commercial therapeutic erbium laser according to Brazilian regulations, and to discuss a risk control program intended to minimize the accidental exposition at dangerous laser radiation levels. It was verified that the analyzed laser can produce lesions in the skin and eyes, when exposed to laser radiation at distances smaller than 80 cm by 10 s or more. In these conditions, the use of protection glasses is recommended to the personnel that have access to the laser operation ambient. It was verified that the user's training and the presence of a target indicator are fundamental to avoid damages in the skin and buccal cavity. It was also verified that the knowledge and the correct use of the equipment safety devices, and the application of technical and administrative measures is efficient to minimize the risk of dangerous expositions to the laser radiation. (author)

  14. On the reliability evaluation of communication equipment for SMART using FMEA

    International Nuclear Information System (INIS)

    Kim, D. H.; Suh, Y. S.; Koo, I. S.; Song, Ki Sang; Han, Byung Rae

    2000-07-01

    This report describes the reliability analysis method for communication equipment using FMEA and FTA. The major equipments to be applicable for SMART communication networks are repeater, bridge, router and gateway and we can apply the FMEA or FTA technique. In the FMEA process, analysis of tagged system, decision of the level of analysis of the target system, drawing reliability block diagram according to the function, decision of failure mode, writing the fault reasons, writing on the FMEA sheet and FMEA level decision are included. Also, the FTA, it is possible to figure out top event reasons and system reliability. We have considered these in mind and we did the FMEA and FTA for NIC, hub, client server and router. Also, we suggested and integrated network model for nuclear power plant and we have shown the reliability analysis procedure according to FTA. If any proprietary communication device is developed, the reliability can be easily determined with proposed procedures

  15. On the reliability evaluation of communication equipment for SMART using FMEA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Suh, Y. S.; Koo, I. S.; Song, Ki Sang; Han, Byung Rae

    2000-07-01

    This report describes the reliability analysis method for communication equipment using FMEA and FTA. The major equipments to be applicable for SMART communication networks are repeater, bridge, router and gateway and we can apply the FMEA or FTA technique. In the FMEA process, analysis of tagged system, decision of the level of analysis of the target system, drawing reliability block diagram according to the function, decision of failure mode, writing the fault reasons, writing on the FMEA sheet and FMEA level decision are included. Also, the FTA, it is possible to figure out top event reasons and system reliability. We have considered these in mind and we did the FMEA and FTA for NIC, hub, client server and router. Also, we suggested and integrated network model for nuclear power plant and we have shown the reliability analysis procedure according to FTA. If any proprietary communication device is developed, the reliability can be easily determined with proposed procedures.

  16. Using Survival Analysis to Evaluate Medical Equipment Battery Life.

    Science.gov (United States)

    Kuhajda, David

    2016-01-01

    As hospital medical device managers obtain more data, opportunities exist for using the data to improve medical device management, enhance patient safety, and evaluate costs of decisions. As a demonstration of the ability to use data analytics, this article applies survival analysis statistical techniques to assist in making decisions on medical equipment maintenance. The analysis was performed on a large amount of data related to failures of an infusion pump manufacturer's lithium battery and two aftermarket replacement lithium batteries from one hospital facility. The survival analysis resulted in statistical evidence showing that one of the third-party batteries had a lower survival curve than the infusion pump manufacturer's battery. This lower survival curve translates to a shorter expected life before replacement is needed. The data suggested that to limit unexpected failures, replacing batteries at a two-year interval, rather than the current industry recommendation of three years, may be warranted. For less than $5,400 in additional annual cost, the risk of unexpected battery failures can be reduced from an estimated 28% to an estimated 7%.

  17. Modern equipment of radiation intrascopie for inspection of welding

    International Nuclear Information System (INIS)

    Sosnin, F.R.

    1976-01-01

    The systems are described of radiation intrascopy of controlled objects studied by x-raying and the effective transformation of the shadow x-ray image into light-shadow one. In order to increase the range of controlled thicknesses and to improve the flaw detector sensitivity of the control, the electron-optical devices and telesivion technology are applied. So it becomes possible, through the amplification of the image, to use the high resolving power of the eye. Four types of modern equipment with amplification of the image have been defined, depending on x-rays and light converters. The main technical characteristics of some devices are given. The motion mechanisms of the controlled objects are considered. All kinds of radiation intrascopy systems developed up to the present time have the sensitivity of control of steel welded objects with thickness 5-50 mm which is 2 to 4 times greater than the sensitivity of the radiographic control method. The x-ray-television control is 2 to 4 times more efficient than radiographic one and is preferable from the safety point of view

  18. 45 CFR 1174.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use... requirements. Procedures for managing equipment (including replacement equipment), whether acquired in whole or... original or replacement equipment acquired under a grant or subgrant is no longer needed for the original...

  19. 45 CFR 1157.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use... requirements. Procedures for managing equipment (including replacement equipment), whether acquired in whole or... original or replacement equipment acquired under a grant or subgrant is no longer needed for the original...

  20. CMOS On-Chip Optoelectronic Neural Interface Device with Integrated Light Source for Optogenetics

    International Nuclear Information System (INIS)

    Sawadsaringkarn, Y; Kimura, H; Maezawa, Y; Nakajima, A; Kobayashi, T; Sasagawa, K; Noda, T; Tokuda, T; Ohta, J

    2012-01-01

    A novel optoelectronic neural interface device is proposed for target applications in optogenetics for neural science. The device consists of a light emitting diode (LED) array implemented on a CMOS image sensor for on-chip local light stimulation. In this study, we designed a suitable CMOS image sensor equipped with on-chip electrodes to drive the LEDs, and developed a device structure and packaging process for LED integration. The prototype device produced an illumination intensity of approximately 1 mW with a driving current of 2.0 mA, which is expected to be sufficient to activate channelrhodopsin (ChR2). We also demonstrated the functions of light stimulation and on-chip imaging using a brain slice from a mouse as a target sample.