WorldWideScience

Sample records for iodine-125 prostate brachytherapy

  1. Iodine-125 seed implantation (permanent brachytherapy) for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Ebara, Shin; Katayama, Yoshihisa; Tanimoto, Ryuta

    2008-01-01

    From January 2004 to March 2007, 308 patients with clinically localized prostate cancer were treated using iodine-125 ( 125 I) seed implantation (permanent brachytherapy) at Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences. We evaluated the treatment's efficacy and morbidity in 300 prostate cancer patients who were followed up for more than 1 month after brachytherapy. Based on the National Comprehensive Cancer Network (NCCN) guidelines, patients with a prostate volume of less than 40 ml in transrectal ultrasound imaging were classified as low or intermediate risk. The median patient age was 67 years (range 50 to 79 years), the median prostate-specific antigen (PSA) value before biopsy was 6.95 ng/ml (range 1.13 to 24.7 ng/ml), and the median prostate volume was 24.33 ml (range 9.3 to 41.76 ml). The median follow-up was 18 months (range 1 to 36 months) and the PSA levels decreased in almost all patients after brachytherapy. Although 194 of 300 patients (64.7%) complained of difficulty in urination, pollakisuria/urgency, miction pain, and/or urinary incontinence, all of which might be associated with radiation prostatitis during the first month after brachytherapy, these symptoms gradually improved. 125 I seed implantation brachytherapy is safe and effective for localized prostate cancer within short-term follow up. (author)

  2. Iodine-125 thin seeds decrease prostate swelling during transperineal interstitial permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Beydoun, Nadine; Bucci, Joseph A.; Chin, Yaw S.; Malouf, David

    2014-01-01

    Prostate swelling following seed implantation is a well-recognised phenomenon. The purpose of this intervention was to assess whether using thinner seeds reduces post-implant swelling with permanent prostate brachytherapy. Eighteen consecutive patients eligible for prostate seed brachytherapy underwent seed implantation using iodine-125 (I-125) thin seeds. Operative time, dosimetry, prostate swelling and toxicity were assessed and compared with standard I-125 stranded seed controls, sourced from the department's brachytherapy database. A learning curve was noted with the thin seeds in terms of greater bending and deviation of needles from their intended path. This translated into significantly longer total operative time (88 vs 103 minutes; P=0.009, 95% confidence interval (CI) 4.1-24.3) and time per needle insertion (2.6 vs 3.7 minutes; P<0.001, 95% CI 0.5-1.3) for the thin seeds. Day 30 prostate volumes were significantly smaller in the thin seed group compared with standard seeds (40.9cc vs 46.8cc; P=0.001, 95% CI 1.5-5.6). The ratio of preoperative transrectal ultrasound to day 30 post-implant CT volume was also smaller in the thin seed group (1.2±0.1 for standard seeds vs 1.1±0.1 for thin seeds). Post-implant dosimetric parameters were comparable for both groups. No significant differences were seen in acute urinary morbidity or quality of life between the two groups. I-125 thin seeds are associated with an initial learning curve, with longer operative time, even for experienced brachytherapists. The significant reduction in day 30 prostate volumes with the thin seeds has useful implications in terms of optimising dose coverage to the prostate in the early period post-implantation, as well as improving the accuracy of post-implant dosimetric assessments.

  3. Outcomes following iodine-125 prostate brachytherapy with or without neoadjuvant androgen deprivation

    International Nuclear Information System (INIS)

    Ohashi, Toshio; Yorozu, Atsunori; Saito, Shiro; Momma, Tetsuo; Toya, Kazuhito; Nishiyama, Toru; Yamashita, Shoji; Shiraishi, Yutaka; Shigematsu, Naoyuki

    2013-01-01

    Purpose: To report the biochemical failure-free survival (BFFS), cause-specific survival (CSS), and overall survival (OS) outcomes of patients treated with iodine-125 (I-125) brachytherapy for clinically localized prostate cancer. Methods and materials: Between 2003 and 2009, I-125 permanent prostate brachytherapy without supplemental external-beam radiotherapy was performed for 663 patients with low-risk and low-tier intermediate-risk (defined as organ-confined disease, PSA <10 ng/mL, and Gleason score 3 + 4 with biopsy positive core rate <33%) prostate cancer. Early in the study period, the preplanning method was used in the first 104 patients, and later the real-time planning method was used. Biochemical failure was determined using the American Society for Therapeutic Radiology Oncology (ASTRO) and Phoenix definitions. Results: The 7-year BFFS rates for the ASTRO and Phoenix definitions were 96.1% and 95.9%, respectively. The corresponding BFFS rates by risk group were 97.6% and 96.7% for low-risk, and 91.8% and 93.6% for low-tier intermediate-risk disease (p = 0.007 and 0.08, respectively). The median times to biochemical failure in those who failed were 29.5 and 43.9 months according to the ASTRO and Phoenix definitions, respectively. The 7-year CSS and OS were 99.1% and 96.4%. There was no significant difference in CSS or OS between the low-risk and low-tier intermediate-risk groups. In multivariate Cox regression analysis, risk group and prostate D90 were independent predictors of BFFS for the ASTRO definition, while only the prostate D90 was significant for the Phoenix definition. Conclusion: I-125 prostate brachytherapy results in excellent 7-year BFFS, CSS, and OS for low-risk and low-tier intermediate-risk prostate cancer

  4. Multivariable model development and internal validation for prostate cancer specific survival and overall survival after whole-gland salvage Iodine-125 prostate brachytherapy

    NARCIS (Netherlands)

    Peters, Max; van der Voort van Zyp, Jochem R N; Moerland, Marinus A; Hoekstra, Carel J; van de Pol, Sandrine; Westendorp, Hendrik; Maenhout, Metha; Kattevilder, Rob; Verkooijen, Helena M; van Rossum, Peter S N; Ahmed, Hashim U; Shah, Taimur T; Emberton, Mark; van Vulpen, Marco

    BACKGROUND: Whole-gland salvage Iodine-125-brachytherapy is a potentially curative treatment strategy for localised prostate cancer (PCa) recurrences after radiotherapy. Prognostic factors influencing PCa-specific and overall survival (PCaSS & OS) are not known. The objective of this study was to

  5. Use of brachytherapy with permanent implants of iodine-125 in localized prostate cancer

    International Nuclear Information System (INIS)

    Bladou, F.; Serment, G.; Salem, N.; Simonian, M.; Rosello, R.; Ternier, F.

    2002-01-01

    Approximately 15,000 cases of early stage prostate cancer T1 and T2 are diagnosed every year in France by testing for PSA and performing prostatic biopsies. The treatment of these localized forms is based in most cases on radical prostatectomy or nn external beam radiotherapy. Although the ontological results obtained by these two therapeutic methods are satisfactory and equivalent in the long term, the side effects can be important. For a number of years, trans-perineal brachytherapy using permanent implants of iodine -125 or palladium-103 has proved itself as an alternative therapy with equivalent medium to long-term results. The low urinary, digestive and sexual side effects of prostate brachytherapy are important reasons for the enthusiasm among patients and the medical community for this therapy and the growing number of applications and centres which practice it. In September 1998 we started the prostate brachytherapy programmes- in Marseilles with close collaboration between the department of urology of the Hopital Salvator, and the departments of radiotherapy, medical imaging and medical physics of the Institut Paoli-Calmettes. To date, around 250 patients with localized adenocarcinoma of the prostate have benefited from this alternative therapy in our centre. Preliminary results, with a 3 year-follow-up, are comparable to results published in the literature by pioneer teams. (authors)

  6. A robotic device for MRI-guided prostate brachytherapy

    NARCIS (Netherlands)

    Lagerburg, V.

    2008-01-01

    One of the treatment options for prostate cancer is brachytherapy with iodine-125 sources. In prostate brachytherapy a high radiation dose is delivered to the prostate with a steep dose fall off to critical surrounding organs. The implantation of the iodine sources is currently performed under

  7. A Phase III Randomized Trial of the Timing of Meloxicam With Iodine-125 Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Crook, Juanita; Patil, Nikhilesh; Wallace, Kris; Borg, Jette; Zhou, David; Ma, Clement; Pond, Greg

    2010-01-01

    Purpose: Nonsteroidal anti-inflammatory medication is used to reduce prostate edema and urinary symptoms following prostate brachytherapy. We hypothesized that a cyclooxygenase-2 (COX-2) inhibitor regimen started 1 week prior to seed implant might diminish the inflammatory response, thus reducing edema, retention rates, and symptom severity. Methods and Materials: From March 2004 to February 2008, 316 men consented to an institutional review board-approved randomized study of a 4-week course of meloxicam, 7.5 mg orally twice per day, starting either on the day of implant or 1 week prior to implant. Brachytherapy was performed using iodine-125 seeds and was preplanned and performed under transrectal ultrasound (TRUS) and fluoroscopic guidance. Prostate volume obtained by MR imaging at 1 month was compared to baseline prostate volume obtained by TRUS planimetry and expressed as an edema factor. The trial endpoints were prostate edema at 1 month, International Prostate Symptom Score (IPSS) questionnaire results at 1 and 3 months, and any need for catheterization. Results: Results for 300 men were analyzed. Median age was 61 (range, 45-79 years), and median TRUS prostate volume was 35.7 cc (range, 18.1-69.5 cc). Median IPSS at baseline was 5 (range, 0-24) and was 15 at 1 month, 16 at 3 months, and 10 at 6 months. Catheterization was required for 7% of patients (6.2% day 0 arm vs. 7.9% day -7 arm; p = 0.65). The median edema factor at 1 month was 1.02 (range, 0.73-1.7). 1.01 day 0 arm vs. 1.05 day -7 arm. Baseline prostate volume remained the primary predictor of postimplant urinary retention. Conclusions: Starting meloxicam 1 week prior to brachytherapy compared to starting immediately after the procedure did not reduce 1-month edema, improve IPSSs at 1 or 3 months, or reduce the need for catheterization.

  8. Assessment of the risks associated with Iodine-125 handling production sources for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Daiane C.B.; Rostelato, Maria Elisa C.; Vicente, Roberto; Zeituni, Carlos A.; Tiezzi, Rodrigo; Costa, Osvaldo L.; Souza, Carla D.; Peleias Junior, Fernando S.; Rodrigues, Bruna T.; Souza, Anderson S.; Batista, Talita Q.; Melo, Emerson R.; Camargo, Anderson R., E-mail: dcsouza@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Karam Junior, Dib, E-mail: dib.karam@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil)

    2015-07-01

    In Brazil, prostate cancer is the second most frequent disease, with an estimated 68,800 new cases in 2013. This type of cancer can be treated with brachytherapy, which uses sealed sources of Iodine-125 implanted permanently in the prostate. These sources are currently imported at a high cost, making public treatment in large scale impractical. To reduce costs and to meet domestic demand, the laboratory for production of brachytherapy sources at the Nuclear and Energy Research Institute (IPEN) is currently nationalizing the production of this radioisotope. Iodine is quite volatile making the handling of its radioactive isotopes potentially dangerous. The aim of this paper is to evaluate the risks to which workers are exposed during the production and handling of the sources. The research method consisted initially of a literature review on the toxicity of iodine, intake limits, related physical risks, handling of accidents, generation of radioactive wastes, etc. The results allowed for establishing safety and radioprotection policies in order to ensure efficient and safe production in all stages and the implementation of good laboratory practices. (author)

  9. Assessment of the risks associated with Iodine-125 handling production sources for brachytherapy

    International Nuclear Information System (INIS)

    Souza, Daiane C.B.; Rostelato, Maria Elisa C.; Vicente, Roberto; Zeituni, Carlos A.; Tiezzi, Rodrigo; Costa, Osvaldo L.; Souza, Carla D.; Peleias Junior, Fernando S.; Rodrigues, Bruna T.; Souza, Anderson S.; Batista, Talita Q.; Melo, Emerson R.; Camargo, Anderson R.; Karam Junior, Dib

    2015-01-01

    In Brazil, prostate cancer is the second most frequent disease, with an estimated 68,800 new cases in 2013. This type of cancer can be treated with brachytherapy, which uses sealed sources of Iodine-125 implanted permanently in the prostate. These sources are currently imported at a high cost, making public treatment in large scale impractical. To reduce costs and to meet domestic demand, the laboratory for production of brachytherapy sources at the Nuclear and Energy Research Institute (IPEN) is currently nationalizing the production of this radioisotope. Iodine is quite volatile making the handling of its radioactive isotopes potentially dangerous. The aim of this paper is to evaluate the risks to which workers are exposed during the production and handling of the sources. The research method consisted initially of a literature review on the toxicity of iodine, intake limits, related physical risks, handling of accidents, generation of radioactive wastes, etc. The results allowed for establishing safety and radioprotection policies in order to ensure efficient and safe production in all stages and the implementation of good laboratory practices. (author)

  10. Use of brachytherapy with permanent implants of iodine-125 in localized prostate cancer; La curietherapie par implants permanents d'I-125 dans le cancer localise de la prostate

    Energy Technology Data Exchange (ETDEWEB)

    Bladou, F.; Serment, G. [Hopital Salvador, Service d' Urologie, 13 - Marseille (France); Salem, N.; Simonian, M. [Hopital Salvador, Dept. de Radiotherapie, 13 - Marseille (France); Rosello, R.; Ternier, F. [Institut Paoli-Calmettes, Dept. de Radiologie, 13 - Marseille (France)

    2002-07-01

    Approximately 15,000 cases of early stage prostate cancer T1 and T2 are diagnosed every year in France by testing for PSA and performing prostatic biopsies. The treatment of these localized forms is based in most cases on radical prostatectomy or nn external beam radiotherapy. Although the ontological results obtained by these two therapeutic methods are satisfactory and equivalent in the long term, the side effects can be important. For a number of years, trans-perineal brachytherapy using permanent implants of iodine -125 or palladium-103 has proved itself as an alternative therapy with equivalent medium to long-term results. The low urinary, digestive and sexual side effects of prostate brachytherapy are important reasons for the enthusiasm among patients and the medical community for this therapy and the growing number of applications and centres which practice it. In September 1998 we started the prostate brachytherapy programmes- in Marseilles with close collaboration between the department of urology of the Hopital Salvator, and the departments of radiotherapy, medical imaging and medical physics of the Institut Paoli-Calmettes. To date, around 250 patients with localized adenocarcinoma of the prostate have benefited from this alternative therapy in our centre. Preliminary results, with a 3 year-follow-up, are comparable to results published in the literature by pioneer teams. (authors)

  11. Development of an automation system for iodine-125 brachytherapy seed production by ND:YAG laser welding

    International Nuclear Information System (INIS)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria Elisa C.M.; Costa, Fabio E.; Calvo, Wilson A.P.

    2009-01-01

    The aim of this work is to develop an automation system for iodine-125 radioactive seed production by Nd:YAG laser welding, which has been used successfully in low dose rate brachytherapy treatment. This small seed consists of a welded titanium capsule, with 0.8 mm in diameter and 4.5 mm in length, containing iodine-125 adsorbed onto a silver rod. The iodine-125 seeds are implanted into the human prostate to irradiate the tumor for cancer treatment. Nowadays, the Radiation Technology Center, at IPEN-CNEN/SP imports and distributes 36,000 iodine-125 seeds per year, for the clinics and hospitals in the country. However, the Brazilian market potential is now over 8,000 iodine-125 seeds per month. The local production of these iodine-125 radioactive sources became a priority for the Institute, in order to reduce the price and the problems of prostate cancer management. It will permit to spread their use to a larger number of patients in Brazil. On the other hand, the industrial automation plays an important role for iodine-125 seeds in order to increase the productivity, with high quality and assurance, avoiding human factors, implementing and operating with good manufacturing practices. The technology consists of appliance electronic and electro-mechanical parts and components to control machines and processes. The automation system technology for iodine-125 seed production developed in this work was mainly assembled employing a Programmable Logic Controller, a stepper motor, an Nd:YAG laser welding machine and a supervisory. (author)

  12. Development of an automation system for iodine-125 brachytherapy seed production by (Nd:YAG) laser welding

    International Nuclear Information System (INIS)

    Somessari, Samir Luiz

    2010-01-01

    The aim of this work is to develop an automation system for iodine-125 radioactive seed production by (Nd:YAG) laser welding, which has been used successfully in Low Dose Rate (LDR) brachytherapy treatment. This small seed consists of a welded titanium capsule, with 0.8mm in diameter and 4.5mm in length, containing iodine-125 adsorbed onto a silver rod. The iodine-125 seeds are implanted into the human prostate to irradiate the tumor for cancer treatment. Nowadays, the Radiation Technology Center, at IPEN-CNEN/SP imports and distributes 36,000 iodine-125 seeds per year, for the clinics and hospitals in the country. However, the Brazilian market potential is now over 8,000 iodine-125 seeds per month. The local production of these iodine-125 radioactive sources becomes a priority for the Institute, in order to reduce the price and the problems of prostate cancer management. It will permit to spread their use to a largest number of patients in Brazil. On the other hand, the industrial automation plays an important role for iodine-125 seeds in order to increase the productivity, with high quality and assurance, avoiding human factors, implementing and operating with Good Manufacturing Practices (GMP). The technology consists of appliance electronic and electro-mechanical parts and components to control machines and processes. The automation system technology for iodine-125 seed production developed in this work was mainly assembled employing Programmable Logic Controller (PLC), stepper motors, drivers, (Nd:YAG) laser welding machine, photoelectric sensors and supervisory. (author)

  13. Development of an automation system for Iodine-125 brachytherapy seed encapsulated by Nd:YAG laser welding

    International Nuclear Information System (INIS)

    Somessari, S.L.; Feher, A.; Sprenger, F.E.; Rostelato, M.E.C.M.; Costa, F.E. da; Calvo, W.A.P.

    2011-01-01

    The aim of this work is to develop an automation system for iodine-125 radioactive seed production by Nd:YAG laser welding, which has been used successfully in low dose rate (LDR) brachytherapy treatment. This small seed consists of a welded titanium capsule, with 0.8 mm in diameter and 4.5 mm in length, containing iodine-125 adsorbed onto a silver rod. The iodine-125 seeds are implanted into the human prostate to irradiate the tumor for cancer treatment. Nowadays, the Radiation Technology Center, at Institute for Nuclear and Energy Research, Sao Paulo, Brazil (IPEN-CNEN/SP) imports and distributes 36,000 iodine-125 seeds per year, for the clinics and hospitals in the country. However, the Brazilian market potential is now over 8,000 iodine-125 seeds per month. The local production of these iodine-125 radioactive sources became a priority for the Institute, in order to reduce the price and the problems of prostate cancer management. It will permit to spread their use to a larger number of patients in Brazil. On the other hand, the industrial automation plays an important role for iodine-125 seeds in order to increase the productivity, with high quality and assurance, avoiding human factors, implementing and operating with good manufacturing practices (GMP). The technology consists of appliance electronic and electro-mechanical parts and components to control machines and processes. The automation system technology for iodine-125 seed production developed in this work was mainly assembled employing a programmable logic controller (PLC), a stepper motor, an Nd:YAG laser welding machine and a supervisory. The statistical repeatability of correctly encapsulated sealed sources with this automation system is greater than 95%. (authors)

  14. American brachytherapy society recommends no change for prostate permanent implant dose prescriptions using iodine-125 or palladium-103

    International Nuclear Information System (INIS)

    Rivard, M.J.; Butler, W.M.; Merrick, G.S.; Devlin, P.M.; Hayes, J.K.; Hearn, R.A.; Lief, E.P.; Meigooni, A.S.; Williamson, J.F.

    2008-01-01

    Purpose - In 2004, the American Association of Physicists in Medicine (AAPM) issued a report outlining recommended 125 I and 103 Pd datasets for consistency in calculating brachytherapy dose distributions. In 2005, to aid evaluating the clinical impact of implementing these datasets, the AAPM assessed the historical dependence of how prescribed doses differed from administered doses for 125 I and 103 Pd for permanent implantation of the prostate. Consequently, the American Brachytherapy Society (ABS) considered the nature of these changes towards issuing recommended dose prescriptions for 125 I and 103 Pd interstitial brachytherapy implants for mono-therapy and standard boosts. Methods and materials - An investigation was performed of the 2005 AAPM analysis to determine changes in administered dose while affixing prescribed dose using 2004 AAPM 125 I and 103 Pd brachytherapy dosimetry datasets for prostate implants. For 125 I and 103 Pd, administered dose would change by +1.4% and +4.2%, respectively. The biological and societal impact of changing prescribed dose was considered. Results - Based on the need for clinical constancy and in recognition of overall uncertainties, the ABS recommends immediate implementation of the 2004 AAPM consensus brachytherapy dosimetry datasets and no changes to 125 I and 103 Pd dose prescriptions at this time. Conclusions - Radiation oncologists should continue to prescribe mono-therapy doses of 145 Gy and 125 Gy for 125 I and 105 Pd, respectively, and standard boost doses of 100-110 Gy and 90-100 Gy for 125 I and 103 Pd, respectively. (authors)

  15. Relationship between two year PSA nadir and biochemical recurrence in prostate cancer patients treated with iodine-125 brachytherapy

    Directory of Open Access Journals (Sweden)

    Carlos Antônio da Silva Franca

    2014-04-01

    Full Text Available Objective To evaluate the relationship between two year PSA nadir (PSAn after brachytherapy and biochemical recurrence rates in prostate cancer patients. Materials and Methods In the period from January 1998 to August 2007, 120 patients were treated with iodine-125 brachytherapy alone. The results analysis was based on the definition of biochemical recurrence according to the Phoenix Consensus. Results Biochemical control was observed in 86 patients (71.7%, and biochemical recurrence, in 34 (28.3%. Mean PSAn was 0.53 ng/ml. The mean follow-up was 98 months. The patients were divided into two groups: group 1, with two year PSAn < 0.5 ng/ml after brachytherapy (74 patients; 61.7%, and group 2, with two year PSAn ≥ 0.5 ng/ml after brachytherapy (46 patients; 38.3%. Group 1 presented biochemical recurrence in 15 patients (20.3%, and group 2, in 19 patients (43.2% (p < 0.02. The analysis of biochemical disease-free survival at seven years, stratified by the two groups, showed values of 80% and 64% (p < 0.02, respectively. Conclusion Levels of two year PSAn ≥ 0.5 ng/ml after brachytherapy are strongly correlated with a poor prognosis. This fact may help to identify patients at risk for disease recurrence.

  16. Iodine-125 seed brachytherapy for early stage prostate cancer: a single-institution review

    International Nuclear Information System (INIS)

    Zuber, Simon; Weiß, Susan; Baaske, Dieter; Schöpe, Michael; Stevens, Simon; Bodis, Stephan; Zwahlen, Daniel R

    2015-01-01

    We are reporting the five-year biochemical control, toxicity profile and dosimetric parameters using iodine-125 low dose rate brachytherapy (BT) as monotherapy for early stage prostate cancer at a single institution. Between April 2006 and December 2010, 169 men with early stage prostate cancer were treated with BT. Biochemical failure was defined using the Phoenix definition (nadir + 2 ng/mL). Treatment-related morbidities, including urinary, rectal and sexual function, were measured, applying the International Prostate Symptom Score (IPSS), the 7-grade Quality of Life Scale (QoL) and medical status, the International Consultation on Incontinence Modular Questionnaire (ICIQ), the International Index of Erectile Function (IIEF-5) and the Common Terminology Criteria for Adverse Events (CTCAE v4.03). Seed migration and loss, dosimetric parameters and learning effects were also analyzed. Medium follow-up time was 50 months (range, 1–85 months). The five-year biochemical failure rate was 7%. Acute proctitis rates were 19% (grade 1) and 1% (grade 2), respectively. The overall incidence of incontinence was 19% (mild), 16% (moderate) and < 1% (severe). An increase in IPSS ≥ 5 points was detected in 59% of patients, with 38% regaining their baseline. Seed dislocation was found in 24% of patients and correlated with D90 and V100. A learning curve was found for seed migration, D90 and V100. QoL correlated with the general health condition of patient, incontinence symptoms and IPSS. BT for early stage prostate cancer offers excellent five-year biochemical control with low toxicities. QoL aspects are favorable. A learning curve was detected for procedural aspects but its impact on patient relevant endpoints remains inconclusive

  17. Iodine-125 seeds for cancer treatment

    Energy Technology Data Exchange (ETDEWEB)

    Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Feher, Anselmo; Moura, Joao A.; Moura, Eduardo S.; Nagatomi, Helio R.; Manzoli, Jose E.; Souza, Carla D., E-mail: elisaros@ipen.b, E-mail: czeituni@pobox.co, E-mail: afeher@ipen.b, E-mail: jmoura31@yahoo.com.b, E-mail: esmoura@ipen.b, E-mail: hrnagato@ipen.b, E-mail: jemanzoli@ipen.b, E-mail: cdsouza@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Karam, Dib, E-mail: dib.karan@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Escola de Artes, Ciencias e Humanidades

    2009-07-01

    In Brazil, cancer has become one of the major public health problems. An estimate by the Health Ministry showed that 466,430 people had the disease in the country in 2008. The prostate cancer is the second largest death cause among men. The National Institute of Cancer estimated the occurrence of 50,000 new cases for 2009. Some of these patients are treated with Brachytherapy, using Iodine-125 seeds. By this technique, small seeds with Iodine-125, a radioactive material, are implanted in the prostate. The advantages of radioactive seed implants are the preservation of healthy tissues and organs near the prostate, besides the low rate of impotence and urinary incontinence. The Energy and Nuclear Research Institute - IPEN, which belongs to the Nuclear Energy National Commission - CNEN, established a program for the development of the technique and production of Iodine-125 seeds in Brazil. The estimate for the 125-Iodine seeds demand is of 8,000 seeds/month and the laboratory to be implanted will need this production capacity. The purpose of this paper is to explain the project status and show some data about the seeds used in the country. The project will be divided in two phases: technological development of a prototype and a laboratory implementation for the seeds production. (author)

  18. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    International Nuclear Information System (INIS)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P.

    2011-01-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  19. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P., E-mail: somessar@ipen.b, E-mail: afeher@ipen.b, E-mail: sprenger@ipen.b, E-mail: elisaros@ipen.b, E-mail: olcosta@ipen.b, E-mail: wapcalvo@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  20. Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy

    International Nuclear Information System (INIS)

    Moura, Eduardo Santana de

    2011-01-01

    The use of brachytherapy technique with iodine-125 seeds to prostate cancer treatment has been used for decades with good clinical outcomes. To aim the Brazilian population necessities, IPEN-CNEN/SP developed the iodine-125 seed prototype with national technology. The objectives of this work are the development and the study of dosimetric procedures associates with the experimental acquisition of the useful parameters for the iodine-125 dosimetric characterization and to evaluate if the developed procedures, in this work, have the basic conditions to determinate the dosimetric analysis, that are fundamental for clinical procedures. The dosimeters selected for the analysis are the TLD-100 (LiF:Mg,Ti), initially these dosimeters were submitted for two selection steps to choose the dosimeters more reproducible for the dosimetric analysis. The two steps were the selection by the mass of the dosimeters and the reproducibility after four irradiation series in a Cobalt-60 irradiator (CTR-IPEN). Afterwards these steps, the dosimeters were irradiated in linear accelerator with 6 MV energy (Service of Radiotherapy - Hospital Israelita Albert Einstein) to yield the individual calibration factors to each dosimeter. After, the dosimeters were used to the irradiations with iodine-125 seed, 6711 model, (GE-Healthcare). The irradiations and others analysis with iodine-125 seeds yield the useful values for the determination of the parameters suggested by the AAPM (American Association of Physicists in Medicine): constant of dose rate, geometry function, dose radial function and anisotropy function. The results showed good agreement with the values published by the literature, for the same iodine- 125 model, this fact confirms that the realized parameters will be able to be used for the IPEN-CNEN iodine-125 seeds dosimetry and quality control. (author)

  1. Development of an encapsulation method using plasma arc welding to produce iodine-125 seeds for brachytherapy

    International Nuclear Information System (INIS)

    Feher, Anselmo; Calvo, Wilson A.P.; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Somessari, Samir L.; Costa, Osvaldo L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R.

    2011-01-01

    The prostate cancer, which is the second cause of death by cancer in men, overcome only by lung cancer is public health problem in Brazil. Brachytherapy is among the possible available treatments for prostate cancer, in which small seeds containing Iodine-125 radioisotope are implanted into the prostate gland. The seed consists of a titanium sealed capsule with 0.8 mm external diameter and 4.5 mm length, containing a central silver wire with adsorbed Iodine-125. The Plasma Arc Welding (PAW) is one of the viable techniques for sealing process. The equipment used in this technique is less costly than in other processes, such as, Laser Beam Welding (LBW). The main purpose of this work was the development of an encapsulation method using PAW. The development of this work has presented the following phases: cutting and cleaning titanium tube, determination of the welding parameters, development of a titanium tube holding device for PAW, sealed sources validation according to ISO 2919 - Sealed Radioactive Sources - General Requirements and Classification, and metallographic assays. The developed procedure to seal Iodine-125 seeds using PAW has shown high efficiency, satisfying all the established requirements of ISO 2919. The results obtained in this work will give the possibility to establish a routine production process according to the orientations presented in resolution RDC 17 - Good Manufacturing Practices to Medical Products defined by the ANVISA - National Agency of Sanitary Surveillance. (author)

  2. Development of an encapsulation method using plasma arc welding to produce iodine-125 seeds for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Feher, Anselmo; Calvo, Wilson A.P.; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Somessari, Samir L.; Costa, Osvaldo L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R., E-mail: afeher@ipen.b, E-mail: wapcalvo@ipen.b, E-mail: elisaros@ipen.b, E-mail: somessar@ipen.b, E-mail: olcosta@ipen.b, E-mail: esmoura@ipen.b, E-mail: cdsouza@ipen.b, E-mail: prela@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The prostate cancer, which is the second cause of death by cancer in men, overcome only by lung cancer is public health problem in Brazil. Brachytherapy is among the possible available treatments for prostate cancer, in which small seeds containing Iodine-125 radioisotope are implanted into the prostate gland. The seed consists of a titanium sealed capsule with 0.8 mm external diameter and 4.5 mm length, containing a central silver wire with adsorbed Iodine-125. The Plasma Arc Welding (PAW) is one of the viable techniques for sealing process. The equipment used in this technique is less costly than in other processes, such as, Laser Beam Welding (LBW). The main purpose of this work was the development of an encapsulation method using PAW. The development of this work has presented the following phases: cutting and cleaning titanium tube, determination of the welding parameters, development of a titanium tube holding device for PAW, sealed sources validation according to ISO 2919 - Sealed Radioactive Sources - General Requirements and Classification, and metallographic assays. The developed procedure to seal Iodine-125 seeds using PAW has shown high efficiency, satisfying all the established requirements of ISO 2919. The results obtained in this work will give the possibility to establish a routine production process according to the orientations presented in resolution RDC 17 - Good Manufacturing Practices to Medical Products defined by the ANVISA - National Agency of Sanitary Surveillance. (author)

  3. Ejaculatory Function After Permanent 125I Prostate Brachytherapy for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Huyghe, Eric; Delannes, Martine; Wagner, Fabien M.; Delaunay, Boris; Nohra, Joe; Thoulouzan, Matthieu; Shut-Yee, J. Yeung; Plante, Pierre; Soulie, Michel; Thonneau, Patrick; Bachaud, Jean Marc

    2009-01-01

    Purpose: Ejaculatory function is an underreported aspect of male sexuality in men treated for prostate cancer. We conducted the first detailed analysis of ejaculatory function in patients treated with permanent 125 I prostate brachytherapy for localized prostate cancer. Patients and Methods: Of 270 sexually active men with localized prostate cancer treated with permanent 125 I prostate brachytherapy, 241 (89%), with a mean age of 65 years (range, 43-80), responded to a mailed questionnaire derived from the Male Sexual Health Questionnaire regarding ejaculatory function. Five aspects of ejaculatory function were examined: frequency, volume, dry ejaculation, pleasure, and pain. Results: Of the 241 sexually active men, 81.3% had conserved ejaculatory function after prostate brachytherapy; however, the number of patients with rare/absent ejaculatory function was double the pretreatment number (p < .0001). The latter finding was correlated with age (p < .001) and the preimplant International Index of Erectile Function score (p < .001). However, 84.9% of patients with maintained ejaculatory function after implantation reported a reduced volume of ejaculate compared with 26.9% before (p < .001), with dry ejaculation accounting for 18.7% of these cases. After treatment, 30.3% of the patients experienced painful ejaculation compared with 12.9% before (p = .0001), and this was associated with a greater number of implanted needles (p = .021) and the existence of painful ejaculation before implantation (p < .0001). After implantation, 10% of patients who continued to be sexually active experienced no orgasm compared with only 1% before treatment. in addition, more patients experienced late/difficult or weak orgasms (p = .001). Conclusion: Most men treated with brachytherapy have conserved ejaculatory function after prostate brachytherapy. However, most of these men experience a reduction in volume and a deterioration in orgasm.

  4. Radiation exposure to operating room staff during prostate brachytherapy using iodine-125 seeds; Exposition radiologique de l'equipe operatoire au cours de curietherapies de prostate par implants permanents d'iode-125

    Energy Technology Data Exchange (ETDEWEB)

    Gagna, G.; Amabile, J.C.; Laroche, P. [Service de protection radiologique des armees (SPRA), 1 bis rue du Lieutenant Raoul Batany, 92141 Clamart Cedex (France); Gauron, C. [Institut national de recherche et de securite (INRS), Departement Etudes et Assistance Medicales, 30 rue Olivier Noyer, 75680 Paris Cedex 14 (France)

    2011-04-15

    The French defense radiation protection service (SPRA) and the French national institute for research and safety (INRS) conducted a joint study to assess the radiation exposure to operating room staff during prostate brachytherapy using iodine-125 seeds at the Val-de-Grace military hospital. The purpose of the study was the assessment of the effective doses, the equivalent doses to the extremities and lens received by a novice team, the different ambient dose equivalent rates measurements and the delineation of areas. After six brachy-therapies, all the recorded doses with whole-body InLight{sup R} OSL and nanoDot{sup R} dosimeters remained below the detection limit for the whole staff. The dose rate measured at the end of implantation by an AT1123{sup R} survey meter is about 170 {mu}Sv/h at the perineum of the patient. The controlled area limit is estimated to be about 20 cm from the patient perineum. From these results, the authors propose recommendations for the categorization of workers, the delineation of areas and the dose monitoring procedures. This study demonstrates that real-time ultrasound-guided trans-perineal prostate brachytherapy delivers low dose to the operators because of the radioactive source characteristics and the instrumentation providing an effective radiation protection for the surgical team. (authors)

  5. Embolization of an iodine-125 radioactive seed from the prostate gland into the right ventricle: An unusual pattern of seed migration

    International Nuclear Information System (INIS)

    Schild, Michael H.; Wong, William W.; Vora, Sujay A.; Ward, Lynn D.; Nguyen, Ba D.

    2009-01-01

    Transperineal permanent brachytherapy using iodine-125 or palladium-103 seeds is a standard treatment modality for localized prostate cancer. Migration of seeds to the lungs is a common phenomenon, whereas migration of seeds to the right ventricle is a rare event. We report a case of iodine-125 seed migration to the right ventricle as demonstrated by chest CT scan and add to the very few published reports on this finding. These rare patients did not suffer adverse effects from such event.

  6. Carcinological results at five years of the prostate brachytherapy by iodine 125 implants. About 327 cases; Resultats carcinologiques a cinq ans de la curietherapie de prostate par implants d'iode 125. A propos de 327 cas

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Bernier, V.; Aletti, P.; Noela, A.; Marchesi, V. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Cormier, L.; Moreau, J.L. [CHU, Service d' Urologie, 54 - Nancy (France)

    2006-11-15

    The prostate brachytherapy by iodine 125 implants is reserved to patients damaged by a favourable prognosis cancer. The objective of this study is to present the carcinological results at five years in these indications with a technique keeping urethra. The achieving of a P.S.A. nadir inferior to 0.5 ng/ml is long. the technique used in this study keeping urethra and respecting the inclusion criteria recommended allows to get results as less equivalent as these ones of big series previously published with a low failure rate. (N.C.)

  7. Brachytherapy with 125-Iodine sources: transport and radiation protection

    International Nuclear Information System (INIS)

    Souza, Carla D.; Zeituni, Carlos A.; Moura, Joao A.; Moura, Eduardo S.; Nagatomi, Helio R.; Feher, Anselmo; Hilario, Katia F.; Rostelato, Maria Elisa C.M.

    2009-01-01

    The estimates for the year 2009 show that 466,730 new cancer cases will occur in Brazil. Prostate cancer is the second most incident type. Brachytherapy, a type of radiotherapy, with Iodine-125 sources are an important form of treatment for this kind of cancer. The Instituto de Pesquisas Energeticas e Nucleares (IPEN) created a project to develop a national prototype of these sources and is implementing a facility for local production. The seeds manufacture in Brazil will allow to diminish the treatment cost and make it possible for a larger number of patients. While the laboratory is not ready, the IPEN import and it distributes seeds. This work aim is to present and evaluate the transport procedures and the radiological protection applied to imported sources in order to assist the procedures for the new laboratory implementation. Before sending to hospitals, the seeds are packed by a radioprotector supervisor, in accordance with CNEN NE 5.01 standard 'Radioactive Material Transport'. Despite Iodine-125 presents low energy photons, around 29 keV, local and personal dosimeters are used during the transport process, as described in CNEN NN 3.01 standard 'Radiological Protection Basic Guideline'. All the results show no contamination and very low exposure, proving the method to be valid. The transport procedure used is correct, according to the regulations. As an result of this work, a new dosimeter should be installed and evaluate in future study. (author)

  8. Prostate-Specific Antigen Bounce After Permanent Iodine-125 Prostate Brachytherapy-An Australian Analysis

    International Nuclear Information System (INIS)

    Zwahlen, Daniel R.; Smith, Ryan; Andrianopoulos, Nick; Matheson, Bronwyn; Royce, Peter; Millar, Jeremy L.

    2011-01-01

    Purpose: To report on prostate-specific antigen (PSA) 'bounces' after 125 I prostate brachytherapy to review the relationship to biochemical control and correlate both clinical and dosimetric variables. Methods and Materials: We analyzed 194 hormone-naive patients with a follow-up of ≥3 years. Four bounce definitions were applied: an increase of ≥0.2 ng/mL (definition I), ≥0.4 ng/mL (definition II), ≥15% (definition III), and ≥35% (definition IV) of a previous value with spontaneous return to the prebounce level or lower. Results: Using definition I, II, III, and IV, a bounce was detected in 50%, 34%, 11%, and 9% of patients, respectively. The median time to onset was 14-16 months, the duration was 12-21.5 months, and the magnitude of the increase was 0.5-2 ng/mL. A magnitude of >2 ng/mL, fulfilling the criteria for biochemical failure (BF) according to the American Society for Therapeutic Radiology and Oncology Phoenix definition, was detected in 11.3%, 16.9%, 47.6%, and 50% using definitions I, II, III, and IV, respectively; 11 patients (5.7%) had true BF. The PSA bounces occurred earlier than BF (p < 0.001). The prediction of BF remains controversial and is probably unrelated to biochemical control. The only statistically significant factor predictive of a PSA bounce was younger age (definitions I and II). Conclusion: PSA bounces are common after brachytherapy. All definitions resulted in a high number of false-positive calls for BF during the first 2 years. The definition of an increase of ≥0.2 ng/mL should be preferred because of the lowest number of false-positive results for BF. Patients experiencing a PSA bounce during the first 2 years after brachytherapy should undergo surveillance every 3-6 months. Additional investigations are recommended for elevated postimplant PSA levels that have not corrected by 3 years of follow-up.

  9. Brazilian demand for Iodine-125 seeds in cancer treatment after a decade of medical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Osvaldo L. da; Souza, Daiane C.B. de; Feher, Anselmo; Moura, João A.; Souza, Carla D.; Oliveira, Henrique B. de; Peleiras Junior, Fernando S.; Zeituni, CArlos A.; Rostelaro, Maria E.C.M., E-mail: olcosta@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Iodine-125 and palladium-103 are radionuclides employed to made medical devices used in cancer treatment known as brachytherapy seeds. These radioactive sealed sources are applied in brain and ophthalmic cancer as a temporary implant to irradiate the tumor and in permanent implants to prostatic cancer. Brazilian Nuclear Energy Commission (CNEN) has the monopoly in Brazil of iodine-125 brachytherapy seeds distribution which is executed for Nuclear and Energy Research Institute (IPEN-CNEN/SP). Along a decade of use in Brazil more than 240 thousand seeds were implanted in patients or used to treat cancer tumors. In this article the Brazilian demand for iodine-125 brachytherapy seeds is analyzed. The demand behavior along a decade of using loose, strand, ophthalmic and brain brachytherapy seeds are shown. The annual quantity of seeds demanded by Brazil has dropped since 2012. The loose seeds which represented until 30% from total brachytherapy seeds used in Brazil decreased to less than 3%. The brain brachytherapy seeds had low demand along the decade and presented zero demand in several years. Concurrent treatment techniques are listed and main trends are discussed. The influence of Brazilian economic crisis and the demand behavior of the main hospitals and clinics that use Iodine-125 brachytherapy are shown. (author)

  10. Brazilian demand for Iodine-125 seeds in cancer treatment after a decade of medical procedures

    International Nuclear Information System (INIS)

    Costa, Osvaldo L. da; Souza, Daiane C.B. de; Feher, Anselmo; Moura, João A.; Souza, Carla D.; Oliveira, Henrique B. de; Peleiras Junior, Fernando S.; Zeituni, CArlos A.; Rostelaro, Maria E.C.M.

    2017-01-01

    Iodine-125 and palladium-103 are radionuclides employed to made medical devices used in cancer treatment known as brachytherapy seeds. These radioactive sealed sources are applied in brain and ophthalmic cancer as a temporary implant to irradiate the tumor and in permanent implants to prostatic cancer. Brazilian Nuclear Energy Commission (CNEN) has the monopoly in Brazil of iodine-125 brachytherapy seeds distribution which is executed for Nuclear and Energy Research Institute (IPEN-CNEN/SP). Along a decade of use in Brazil more than 240 thousand seeds were implanted in patients or used to treat cancer tumors. In this article the Brazilian demand for iodine-125 brachytherapy seeds is analyzed. The demand behavior along a decade of using loose, strand, ophthalmic and brain brachytherapy seeds are shown. The annual quantity of seeds demanded by Brazil has dropped since 2012. The loose seeds which represented until 30% from total brachytherapy seeds used in Brazil decreased to less than 3%. The brain brachytherapy seeds had low demand along the decade and presented zero demand in several years. Concurrent treatment techniques are listed and main trends are discussed. The influence of Brazilian economic crisis and the demand behavior of the main hospitals and clinics that use Iodine-125 brachytherapy are shown. (author)

  11. Health-Related Quality of Life up to Six Years After 125I Brachytherapy for Early-Stage Prostate Cancer

    International Nuclear Information System (INIS)

    Roeloffzen, Ellen M.A.; Lips, Irene M.; Gellekom, Marion P.R. van; Roermund, Joep van; Frank, Steven J.; Battermann, Jan J.; Vulpen, Marco van

    2010-01-01

    Purpose: Health-related quality of life (HRQOL) after prostate brachytherapy has been extensively described in published reports but hardly any long-term data are available. The aim of the present study was to prospectively assess long-term HRQOL 6 years after 125 I prostate brachytherapy. Methods and Materials: A total of 127 patients treated with 125 I brachytherapy for early-stage prostate cancer between December 2000 and June 2003 completed a HRQOL questionnaire at five time-points: before treatment and 1 month, 6 months, 1 year, and 6 years after treatment. The questionnaire included the RAND-36 generic health survey, the cancer-specific European Organization for Research and Treatment of Cancer core questionnaire (EORTCQLQ-C30), and the tumor-specific EORTC prostate cancer module (EORTC-PR25). A change in a score of ≥10 points was considered clinically relevant. Results: Overall, the HRQOL at 6 years after 125 I prostate brachytherapy did not significantly differ from baseline. Although a statistically significant deterioration in HRQOL at 6 years was seen for urinary symptoms, bowel symptoms, pain, physical functioning, and sexual activity (p 125 I prostate brachytherapy. HRQOL scores returned to approximately baseline values at 1 year and remained stable up to 6 years after treatment. 125 I prostate brachytherapy did not adversely affect patients' long-term HRQOL.

  12. Iodine-125 implants for carcinoma of the prostate

    International Nuclear Information System (INIS)

    Peschel, R.E.; Fogel, T.D.; Kacinski, B.M.; Kelly, K.; Mate, T.P.

    1985-01-01

    One hundred-thirteen patients underwent Iodine-125 prostate implant and lymphadenectomy at Yale-New Haven Hospital from 1974 through 1980. The distribution by clinical stage was: 7 Stage A2, 86 Stage B, and 20 Stage C patients. Ninety-four patients had a negative lymphadenectomy and 19 patients (17%) had metastatic disease in the pelvic lymph nodes (N+). The actuarial 5-year survival for all 113 patients was 87%. Local tumor control was 85% for all Stage B patients and 75% for all Stage C patients. Only 10 patients (9%) have developed long-term gastrointestinal or genitourinary complications following their implant. Iodine-125 implant appears to be a reasonable alternate form of therapy in highly selected groups of patients with carcinoma of the prostate

  13. Leakage test evaluation used for qualification of iodine-125 seeds sealing

    International Nuclear Information System (INIS)

    Feher, Anselmo; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Calvo, Wilson A.P.; Somessari, Samir L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R.

    2009-01-01

    The prostate cancer is a problem of public health in Brazil, and the second cause of cancer deaths in men, exceeded only by lung cancer. Among the possible treatments available for prostate cancer is brachytherapy, in which small seeds containing Iodine-125 radioisotope are implanted in the prostate. The seed consists of a sealed titanium tube measuring 0.8 mm external diameter and 4.5 mm in length, containing a central silver wire with adsorbed Iodine-125. The tube sealing is made with titanium at the ends, using electric arc welding or laser process. This sealing must be leakage-resistant and free of cracks, therefore avoiding the Iodine-125 to deposit in the silver wire to escape and spread into the human body. To ensure this problem does not occur, rigorous leakage tests, in accordance with the standard Radiation protection - Sealed Radioactive Sources - leakage Test Methods - ISO 9978, should be applied. The aim of this study is to determine, implement and evaluate the leakage test to be used in the Iodine-125 seeds production, in order to qualify the sealing procedure. The standard ISO 9978 presents a list of tests to be carried out according to the type of source. The preferential methods for brachytherapy sources are soaking and helium. To assess the seeds leakage, the method of immersion test at room temperature was applied. The seeds are considered leakage-free if the detected activity does not exceed the 185 Bq (5 nCi). An Iodine standard was prepared and its value determined in a sodium iodide detector. A liquid scintillation counter was calibrated with the standard for seeds leakage tests. Forty-eight seeds were welded for these tests. (author)

  14. Orgasm after prostate curietherapy with iodine 125 permanent implants for localized cancer of the prostate

    International Nuclear Information System (INIS)

    Delaunay, B.; Plante, P.; Huyghe, E.; Delannes, M.; Bachaud, J.-M.; Salloum, A.; Thoulouzan, M.; Soulie, M.; Delavierre, D.; Wagner, F.; Jonca, F.

    2011-01-01

    Orgasm is a domain of male sexuality that remains underreported in literature. Our aim was to realize the first detailed analysis of orgasm in patients treated by 125 I permanent prostate brachytherapy for localized prostate cancer. In a series of 270 sexually active men treated by prostate brachytherapy ( 125 I permanent implantation), 241 (89%), mean age of 65 (43 80), participated in a mailed survey about sexual function after a mean time of 36 months (9 70). Erectile and ejaculatory functions and orgasm were explored using a mailed questionnaire. Two questions focused on orgasm. The first was about quality of orgasm (fast/intense/late, difficult/weak/absent) and the second about the presence of painful orgasm and its frequency (always/sometimes/often). After prostate brachytherapy, 81.3% of sexually active men conserved ejaculation and 90% orgasm. There was a significant deterioration of the quality of orgasm (P ≡ 0.0001). More than 50% of the patients had an altered orgasm (weak, difficult, absent) after brachytherapy, vs 16% before implantation (P ≡ 0.001). Men with a diminished ejaculation volume often had a weak/difficult orgasm (P ≡ 0.007). Neoadjuvant hormonal therapy did not seem to impact the quality of orgasm or the frequency of painful ejaculation. Patients who had an IIEF-5 score higher than 12 had frequently intense orgasm (26.7% vs 2.7%; P < 0.001) after brachytherapy. Sixty patients (30.3%) experienced often/sometimes painful ejaculation 12.9% (n ≡ 31) before implantation (P ≡ 0.0001). Most of the patients treated by prostate brachytherapy conserved orgasm after treatment. However, most of the patients described a deterioration of the quality of orgasm. (authors)

  15. Development of an automation system for iodine-125 brachytherapy seed production by (Nd:YAG) laser welding; Automacao do processo de soldagem a laser (Nd:YAG) para confeccao das sementes de iodo-125 utilizadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir Luiz

    2010-07-01

    The aim of this work is to develop an automation system for iodine-125 radioactive seed production by (Nd:YAG) laser welding, which has been used successfully in Low Dose Rate (LDR) brachytherapy treatment. This small seed consists of a welded titanium capsule, with 0.8mm in diameter and 4.5mm in length, containing iodine-125 adsorbed onto a silver rod. The iodine-125 seeds are implanted into the human prostate to irradiate the tumor for cancer treatment. Nowadays, the Radiation Technology Center, at IPEN-CNEN/SP imports and distributes 36,000 iodine-125 seeds per year, for the clinics and hospitals in the country. However, the Brazilian market potential is now over 8,000 iodine-125 seeds per month. The local production of these iodine-125 radioactive sources becomes a priority for the Institute, in order to reduce the price and the problems of prostate cancer management. It will permit to spread their use to a largest number of patients in Brazil. On the other hand, the industrial automation plays an important role for iodine-125 seeds in order to increase the productivity, with high quality and assurance, avoiding human factors, implementing and operating with Good Manufacturing Practices (GMP). The technology consists of appliance electronic and electro-mechanical parts and components to control machines and processes. The automation system technology for iodine-125 seed production developed in this work was mainly assembled employing Programmable Logic Controller (PLC), stepper motors, drivers, (Nd:YAG) laser welding machine, photoelectric sensors and supervisory. (author)

  16. Implication for QOL after I-125 brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Teishima, Jun; Yasumoto, Hiroaki; Inoue, Syogo; Masumoto, Hiroshi; Hasegawa, Yasuhisa; Matsubara, Akio

    2009-01-01

    The aim of this study is to evaluate the quality of life (QOL) of patients following prostate brachytherapy. Between July 2004 and May 2008, 139 patients underwent I-125 permanent brachytherapy. Among those patients, 69 who were followed up for more than one year using the Expanded Prostate Index Composite (EPIC), Japanese version v1 TM , were enrolled in this study. Urinary summary scores became worse temporarily at 1 month after the end of treatment, but then recovered gradually to the level before treatment. Sexual summary scores before treatment were 42.2±16.3. They became worse temporarily at 1 month after treatment but then recovered gradually in patients whose sexual summary scores were more than 40. Urinary morbidity scores after prostate brachytherapy were not so severe and recovered within a short period. Further long-term observation is thought to be required in the future. Sexual function scores of patients before treatment in the present study were lower compared with those recorded in previous studies. (author)

  17. [Orgasm after curietherapy with permanent iodine-125 radioimplants for localized prostate cancer].

    Science.gov (United States)

    Delaunay, B; Delannes, M; Salloum, A; Delavierre, D; Wagner, F; Jonca, F; Thoulouzan, M; Plante, P; Bachaud, J-M; Soulie, M; Huyghe, E

    2011-12-01

    Orgasm is a domain of male sexuality that remains underreported in literature. Our aim was to realize the first detailed analysis of orgasm in patients treated by 125 I permanent prostate brachytherapy for localized prostate cancer. In a series of 270 sexually active men treated by prostate brachytherapy (125I permanent implantation), 241 (89%), mean age of 65 (43-80), participated in a mailed survey about sexual function after a mean time of 36 months (9-70). Erectile and ejaculatory functions and orgasm were explored using a mailed questionnaire. Two questions focused on orgasm. The first was about quality of orgasm (fast/intense/late, difficult/weak/absent) and the second about the presence of painful orgasm and its frequency (always/sometimes/often). After prostate brachytherapy, 81.3% of sexually active men conserved ejaculation and 90% orgasm. There was a significant deterioration of the quality of orgasm (P=0.0001). More than 50% of the patients had an altered orgasm (weak, difficult, absent) after brachytherapy, vs 16% before implantation (P=0.001). Men with a diminished ejaculation volume often had a weak/difficult orgasm (P=0.007). Neoadjuvant hormonal therapy did not seem to impact the quality of orgasm or the frequency of painful ejaculation. Patients who had an IIEF-5 score higher than 12 had frequently intense orgasm (26.7% vs 2.7%; Porgasm after treatment. However, most of the patients described a deterioration of the quality of orgasm. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  18. Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy; Estudo e levantamentos de parametros para dosimetria de fontes de iodo-125 aplicadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo Santana de

    2011-07-01

    The use of brachytherapy technique with iodine-125 seeds to prostate cancer treatment has been used for decades with good clinical outcomes. To aim the Brazilian population necessities, IPEN-CNEN/SP developed the iodine-125 seed prototype with national technology. The objectives of this work are the development and the study of dosimetric procedures associates with the experimental acquisition of the useful parameters for the iodine-125 dosimetric characterization and to evaluate if the developed procedures, in this work, have the basic conditions to determinate the dosimetric analysis, that are fundamental for clinical procedures. The dosimeters selected for the analysis are the TLD-100 (LiF:Mg,Ti), initially these dosimeters were submitted for two selection steps to choose the dosimeters more reproducible for the dosimetric analysis. The two steps were the selection by the mass of the dosimeters and the reproducibility after four irradiation series in a Cobalt-60 irradiator (CTR-IPEN). Afterwards these steps, the dosimeters were irradiated in linear accelerator with 6 MV energy (Service of Radiotherapy - Hospital Israelita Albert Einstein) to yield the individual calibration factors to each dosimeter. After, the dosimeters were used to the irradiations with iodine-125 seed, 6711 model, (GE-Healthcare). The irradiations and others analysis with iodine-125 seeds yield the useful values for the determination of the parameters suggested by the AAPM (American Association of Physicists in Medicine): constant of dose rate, geometry function, dose radial function and anisotropy function. The results showed good agreement with the values published by the literature, for the same iodine- 125 model, this fact confirms that the realized parameters will be able to be used for the IPEN-CNEN iodine-125 seeds dosimetry and quality control. (author)

  19. Permanent interstitial implantation of 125Iodine seed for thoracic malignant tumors

    International Nuclear Information System (INIS)

    Xu Zhongheng; Qian Yongyue; Wu Jinchang; Liu Zengli

    2002-01-01

    Objective: To observe effect of 125 Iodine sed on interstitial brachytherapy of patient with thoracic malignant tumor. Methods: 125 Iodine seed were inserted into the target tissue and permanent left there for brachytherapy in 6 cases of thoracic malignant tumors, which including lung cancer, Pancoast's tumour, mediastinal malignant schwannoma. Results: All cases were rehabilitated shortly after operation. The implanted lesions remained controlled now and in dead patients. No radiation-related and 125 Iodine seed-related complications occurred. Conclusion: Brachytherapy by implantation of 125 Iodine seeds of remained tumor tissue in patients with thoracic malignant tumor after operation has a satisfactory outcome. This therapy can control local recurrent of thoracic malignant tumor. But the results in long term should be studied further

  20. Dosimetric study of permanent prostate brachytherapy utilizing 131Cs, 125I and 103Pd seeds

    International Nuclear Information System (INIS)

    Yang Ruijie; Wang Junjie; Zhang Hongzhi

    2009-01-01

    Objective: To compare the dosimetric differences of permanent prostate brachytherapy utilizing 131 Cs, 125 I and 103 Pd seeds. Methods: Twenty-five patients with T 1 -T 2 c prostate cancer who had previously implanted with 125 I seeds were randomly selected in our study. The patients were re-planned with 131 Cs, 125 I and 103 Pd seeds by using the Prowess Brachytherapy 3.1 planning system to the prescription doses of 115 Gy, 145 Gy and 125 Gy, respectively. The seed strengths were 1.8 U,0.5 U and 1.8 U, respectively. The prostate, prostatic urethra and anterior wall of the rectum were contoured on trans-rectal ultrasound images. PTV was outlined based on the prostate volume with no margin applied. The attempted planning goals were that V 100 (the percentage volume of the prostate receiving at least 100% of the prescription doses)= 95%, D 90 (the minimum percentage dose covering 90% of the prostate volume) ≥100%, and prostatic urethra UD 10 (the maximum percentage dose receiving by 10% of the contoured urethra) ≤150%. For the plan comparison, we also computed prostate V 150 , prostatic urethra UV 120 , rectum RV 100 , and the number of implanted seeds and needles. The significance of the differences was tested using one way analysis of variance. Results: The average V 200 in the 103 Pd, 125 I and 131 Cs plans were 28.7%, 20.9% and 19.6% (F=42.50, P=0.000); the average V 150 were 51.9%, 42.1% and 39.4% (F=26.15, P=0.000); the average UV 120 were 26.9%, 29.5% and 23.8% (F=0.37, P=0.691); and the average rectum RV 100 were 0.31 cm 3 , 0.22 cm 3 and 0.19 cm 3 (F=0.43, P=0.652). For 103 Pd, 125 I and 131 Cs, the average number of implanted seeds per cm 3 prostate were 2.02, 2.01 and 1.87 (F=1.92, P=0.154), and the average number of needles were 33.6, 32.9 and 31.6 (F=0.26,P=0.772). Conclusions: Comparing to 125 I and 103 Pd seeds used in permanent prostate brachytherapy, 131 Cs seeds has better dose homogeneity, and possible better sparing of the urethra and rectum

  1. Methodology study for fixation of radioactive iodine in polymeric substrate for brachytherapy sources

    International Nuclear Information System (INIS)

    Rodrigues, Bruna T.; Rostelato, Maria Elisa C.M.; Souza, Carla D.; Tiezzi, Rodrigo; Souza, Daiane B. de; Benega, Marcos A.G.; Souza, Anderson S. de; Peleias Junior, Fernando S.; Zeituni, Calos A.; Fernandes, Vagner; Melo, Emerson Ronaldo de; Camargo, Anderson Rogerio de

    2015-01-01

    Cancer is now the second leading cause of death by disease in several countries, including Brazil. Prostate cancer is the most common among men. Brachytherapy is a modality of radiotherapy in which radioactive seeds are placed inside or in contact with the organ to be treated. The most widely used radioisotope in prostate brachytherapy is Iodine-125 which is presented fixated on a silver substrate that is subsequently placed inside a titanium capsule. A large dose of radiation is released only in the targeted tumor protecting healthy surrounding tissues. The technique requires the application of 80 - 120 seeds per patient. The implants of seeds have low impact and non-surgical procedures. Most patients can return to normal life within three days with little or no pain. This work proposes an alternative to the seeds that have already been developed, in order to reduce the cost by obtaining a better efficiency on fixing the radioactive iodine onto the epoxy resin. Methods have been developed to perform the fixation of Iodine-125 onto polymeric substrates. The parameters analyzed were the immersion time, type of static or dynamic reaction, concentration of the adsorption solution, the specific activity of the radioactive source, the need for carrier and chemical form of the radioactive Iodine. These experiments defined the most effective method to fixate the Iodine onto the polymeric material (epoxy resin), the Iodine activity in the polymeric substrate, the activity of the distribution of variation in a plot of polymeric cores and the efficiency of the epoxy resin to seal the seed. (author)

  2. Adjuvant iodine-125 brachytherapy for hepatocellular carcinoma after complete hepatectomy: a randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Kaiyun Chen

    Full Text Available BACKGROUND: Tumor recurrence is a major problem after curative resection of hepatocellular carcinoma (HCC. The current study evaluated the effects of adjuvant iodine-125 ((125I brachytherapy on postoperative recurrence of HCC. METHODOLOGY/PRINCIPAL FINDINGS: From July 2000 to June 2004, 68 HCC patients undergoing curative hepatectomy were randomly assigned into a (125I adjuvant brachytherapy group (n = 34 and a group of best care (n = 34. Patients in the (125I adjuvant brachytherapy group received (125I seed implantation on the raw surface of resection. Patients in the best care control group received identical treatments except for the (125I seed implantation. Time to recurrence (TTR and 1-, 3- and 5-year overall survival (OS were compared between the two groups. The follow-up ended in January 2010, and lasted for 7.7-106.4 months with a median of 47.6 months. TTR was significantly longer in the (125I group (mean of 60.0 months vs. 36.7 months in the control. The 1-, 3- and 5-year recurrence-free rates of the (125I group were 94.12%, 76.42%, and 73.65% vs. 88.24%, 50.00%, and 29.41% compared with the control group, respectively. The 1-, 3- and 5-year OS rates of the (125I group were 94.12%, 73.53%, and 55.88% vs. 88.24%, 52.94%, and 29.41% compared with the control group, respectively. The (125I brachytherapy decreased the risk of recurrence (HR = 0.310 and the risk of death (HR = 0.364. Most frequent adverse events in the (125I group included nausea, vomiting, arrhythmia, decreased white blood cell and/or platelet counts, and were generally mild and manageable. CONCLUSIONS/SIGNIFICANCE: Adjuvant (125I brachytherapy significantly prolonged TTR and increased the OS rate after curative resection of HCC. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ACTRN12610000081011.

  3. Iodine 125 seed migration after prostate brachytherapy: a study of 170 patients

    International Nuclear Information System (INIS)

    Chauveinc, L.; Osseili, A.; Rosenwald, J.C.; Cosset, J.M.; Flam, T.; Thiounn, N.; Savignoni, A.

    2004-01-01

    Purpose. To study the number of migrating seeds, the anatomical site of migration and possible predictive parameters of migration, after prostate cancer brachytherapy using a loose-seed (I125) implantation technique. Patients and methods. The charts of the 170 patients consecutively treated by the Institut Curie/Hospital Cochin/Hospital Necker Group between September 1, 2001 and August 31, 2002, were analysed. All seeds having migrated to the lungs and seen on the chest X-ray systematically performed at 2 months, have been recorded, as well as the seeds lost by the urines (after sieving) or in the sperm (condom). Results. Among 12,179 implanted seeds, 44 were found to have migrated (0.36%). Most of the migrating seeds (32/44; 73%), were found in the lungs. Overall, one or several seed migrations were observed in 35 patients (21% of the total number of patients in this series). In the majority of cases (77< r i. only one seed migrated. A significant relationship (P = 0.04) vs as found between the number of migrating seeds and the number of implanted ones (or with the prostate volume, but those two parameters were closely linked in our series). More specifically, a significant relationship (P = 0.02) could be demonstrated between the number of seeds implanted at the periphery of the prostate and the number of seeds migrating to the lungs. Conclusion. The percentage of migrating seeds observed in this series is low. actually one of the lowest found in the literature when using the loose-seed technique. There was no clinical consequences and the loss of-usually only one seed is very unlikely to alter the quality of the dose distribution. However, the predominance of pulmonary migrations in our series led us to slightly modify our implantation technique. We now try to avoid too 'peripheral' seed implantations, due to the risk of migration towards the peri-prostatic veins, and subsequently to the lungs. (author)

  4. Prediction of PSA bounce after permanent prostate brachytherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Kanai, Kunimitsu; Nakashima, Jun; Sugawara, Akitomo

    2009-01-01

    We aimed to calculate the frequency and features of the development of a prostate-specific antigen (PSA) bounce after prostate brachytherapy alone, to correlate the bounce with clinical and dosimetric factors and to identify factors that predict PSA bounce. PSA bounce was evaluated in 86 patients with T1-T2 prostate cancer who underwent radioactive seed implantation using iodine-125 (I-125) without hormonal therapy or external-beam radiation therapy (EBRT) from September 2004 to December 2007. A PSA bounce was defined as a rise of at least 0.4 ng/ml greater than a previous PSA level with a subsequent decline equal to, or less than, the initial nadir. Calculated by the Kaplan-Meier method, the incidence of PSA bounce at a 2-year follow-up was 26%. Median time to the PSA bounce was 15 months. Univariate analysis demonstrated that age, dose received by 90% of the prostate gland (D90), volume of gland receiving 100% of the prescribed dose (V100), and V150 were significantly associated with the PSA bounce, while pretreatment PSA level, Gleason score, pretreatment prostate volume, clinical T stage, and V200 were not. In multivariate analysis, age 67 years or less and D90 more than 180 Gy were identified as independent factors for predicting the PSA bounce (P<0.05). PSA bounce is not a rare phenomenon after prostate brachytherapy. It is more common in younger patients and patients receiving higher doses of radiation. (author)

  5. Quality Assurance Procedure Development in Iodine-125 Seeds Production

    International Nuclear Information System (INIS)

    Moura, J.A.; Moura, E.S.; Sprenger, F.E.

    2009-01-01

    Brachytherapy using Iodine-125 seeds has been used in prostate cancer treatment. In the quality control routine during seed production, leak tests are made to detect any leakage of radioactive material from inside the titanium shield. Leak tests are made according to the International Standard Organization- Radiation protection - sealed radioactive sources - ISO 9978 standard, and require liquid transfer between recipients. If any leakage happens, there will be contamination of the liquid and tubing. This study aims to establish decontamination routines for tubing, allowing its repeated use, in the automated assay process

  6. External beam radiation therapy and a low-dose-rate brachytherapy boost without or with androgen deprivation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Strom, Tobin J.; Hutchinson, Sean Z.; Shrinath, Kushagra; Cruz, Alex A.; Figura, Nicholas B.; Nethers, Kevin; Biagioli, Matthew C.; Fernandez, Daniel C.; Heysek, Randy V.; Wilder, Richard B., E-mail: richard.wilder@moffitt.org [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States)

    2014-07-15

    Purpose: To assess outcomes with external beam radiation therapy (EBRT) and a low-dose-rate (LDR) brachytherapy boost without or with androgen deprivation therapy (ADT) for prostate cancer. Materials and Methods: From January 2001 through August 2011, 120 intermediate-risk or high-risk prostate cancer patients were treated with EBRT to a total dose of 4,500 cGy in 25 daily fractions and a palladium-103 LDR brachytherapy boost of 10,000 cGy (n = 90) or an iodine-125 LDR brachytherapy boost of 11,000 cGy (n = 30). ADT, consisting of a gonadotropin-releasing hormone agonist ± an anti-androgen, was administered to 29/92 (32%) intermediate-risk patients for a median duration of 4 months and 26/28 (93%) high-risk patients for a median duration of 28 months. Results: Median follow-up was 5.2 years (range, 1.1-12.8 years). There was no statistically-significant difference in biochemical disease-free survival (bDFS), distant metastasis-free survival (DMFS), or overall survival (OS) without or with ADT. Also, there was no statistically-significant difference in bDFS, DMFS, or OS with a palladium-103 vs. an iodine-125 LDR brachytherapy boost. Conclusions: There was no statistically-significant difference in outcomes with the addition of ADT, though the power of the current study was limited. The Radiation Therapy Oncology Group 0815 and 0924 phase III trials, which have accrual targets of more than 1,500 men, will help to clarify the role ADT in locally-advanced prostate cancer patients treated with EBRT and a brachytherapy boost. Palladium-103 and iodine-125 provide similar bDFS, DMFS, and OS. (author)

  7. Prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Abreu, Carlos Eduardo Vita; Silva, Joao L. F.; Srougi, Miguel; Nesrallah, Adriano

    1999-01-01

    The transperineal brachytherapy with 125 I/Pd 103 seed implantation guided by transurethral ultrasound must be presented as therapeutical option of low urinary morbidity in patients with localized prostate cancer. The combined clinical staging - including Gleason and initial PSA - must be encouraged, for definition of a group of low risk and indication of exclusive brachytherapy. Random prospective studies are necessary in order to define the best role of brachytherapy, surgery and external beam radiation therapy

  8. Iodine 125 prostate brachytherapy: prognostic factors for long-term urinary, digestive and sexual toxicities

    International Nuclear Information System (INIS)

    Doyen, J.; Mohammed Ali, A.; Ginot, A.; Ferre, M.; Castelli, J.; Hannoun-Levi, J.M.; Chamorey, E.; Mohammed Ali, A.; Quintens, H.; Amiel, J.

    2009-01-01

    Purpose For patients with good urinary function and presenting with a low risk prostate cancer, prostate brachytherapy using iodine implants represents one of the techniques of reference. This retrospective analysis investigates urinary (U), digestive (D) and sexual (S) toxicities and their prognostic factors of duration. Material and methods From August 2000 to November 2007, 176 patients presenting with prostate adenocarcinoma underwent interstitial brachytherapy. Urinary, digestive and sexual toxicities were classified according to Common toxicities criteria for adverse events, version 3.0 (C.T.C.A.E. V 3.0). For each toxicity (U, D, S), the number of complications U (dysuria, nicturia), D (proctitis, diarrhea) and S (sexual dysfunction, loss of libido) was listed and analyzed according to criteria related to the patient, implant, dosimetric data and characteristics of the toxicity. Prognostic factors identified in univariate analysis (U.V.A.) (Log Rank) were further analyzed in multivariate analysis (M.V.A.) (Cox model). Results With a median follow-up of 26 months (1-87), 147 patients (83.5 %) presented urinary toxicities. Among them, 29.5 % (86 patients) and 2.4 % (seven patients) presented grade 2 and 3 U toxicity respectively. In U.V.A., urinary grade toxicity greater than or equal to 2 (p = 0.037), the presence of initial U symptoms (p = 0.027) and more than two urinary toxicities (p 0.00032) were recognized as prognostic factors. The number of U toxicities was the only prognostic factor in M.V.A. (p = 0.04). D toxicity accounted for 40.6 % (71 patients). Among them, 3 % (six patients) were grade 2. None were grade 3. Two factors were identified as prognostic factors either in U.V.A. and M.V.A.: the number of D toxicities greater than or equal to 2 (univariate analysis: p = 0,00129, multivariate analysis: p = 0,002) and age less than or equal to 65 years (univariate analysis: p = 0,004, multivariate analysis: p 0,007). Eighty-three patients (47

  9. Study and methodology development for quality control in the production process of iodine-125 radioactive sealed sources applied to brachytherapy

    International Nuclear Information System (INIS)

    Moura, Joao Augusto

    2009-01-01

    Today cancer is the second cause of death by disease in several countries, including Brazil. Excluding skin cancer, prostate cancer is the most incident in the population. Prostate tumor can be treated by several ways, including brachytherapy, which consists in introducing sealed radioactive sources (Iodine - 125 seeds) inside the tumor. The target region of treatment receives a high radiation dose, but healthy neighbor tissues receive a significantly reduced radiation dose. The seed is made of a welding sealed titanium capsule, 0.8 mm external diameter and 4.5 mm length, enclosing a 0.5 mm diameter silver wire with Iodine-125 adsorbed. After welded, the seeds have to be submitted to a leak test to prevent any radioactive material release. The aims of this work were: (a) the study of the different leakage test methods applied to radioactive seeds and recommended by the ISO 997820, (b) the choice of the appropriate method and (c) the flowchart determination of the process to be used during the seeds production. The essays exceeded the standards with the use of ultra-sound during immersion and the corresponding benefits to leakage detection. Best results were obtained with the immersion in distilled water at 20 degree C for 24 hours and distilled water at 70 degree C for 30 minutes. These methods will be used during seed production. The process flowchart has all the phases of the leakage tests according to the sequence determined in the experiments. (author)

  10. Relationship between two year PSA nadir and biochemical recurrence in prostate cancer patients treated with iodine-125 brachytherapy; A relacao entre PSA nadir de dois anos e recidiva bioquimica no tratamento do cancer de prostata com braquiterapia de semente de iodo-125

    Energy Technology Data Exchange (ETDEWEB)

    Franca, Carlos Antonio da Silva; Vieira, Sergio Lannes; Penna, Antonio Belmiro Rodrigues Campbell, E-mail: carlosfranca@cremerj.org.br [Instituto Brasileiro de Oncologia (IBO), Rio de Janeiro, RJ (Brazil); Radioterapia Botafogo, Rio de janeiro, RJ (Brazil); Carvalho, Antonio Carlos Pires [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Bernabe, Antonio Jose Serrano [Radioterapia Botafogo, Rio de janeiro, RJ (Brazil)

    2014-03-15

    Objective: to evaluate the relationship between two year PSA nadir (PSAn) after brachytherapy and biochemical recurrence rates in prostate cancer patients. Materials and methods: In the period from January 1998 to August 2007, 120 patients were treated with iodine-125 brachytherapy alone. The results analysis was based on the definition of biochemical recurrence according to the Phoenix Consensus. Results: biochemical control was observed in 86 patients (71.7%), and biochemical recurrence, in 34 (28.3%). Mean PSAn was 0.53 ng/ml. The mean follow-up was 98 months. The patients were divided into two groups: group 1, with two year PSAn < 0.5 ng/ml after brachytherapy (74 patients; 61.7%), and group 2, with two year PSAn ≥ 0.5 ng/ml after brachytherapy (46 patients; 38.3%). Group 1 presented biochemical recurrence in 15 patients (20.3%), and group 2, in 19 patients (43.2%) (p < 0.02). The analysis of biochemical disease-free survival at seven years, stratified by the two groups, showed values of 80% and 64% (p < 0.02), respectively. Conclusion: levels of two year PSAn ≥ 0.5 ng/ml after brachytherapy are strongly correlated with a poor prognosis. This fact may help to identify patients at risk for disease recurrence. (author)

  11. Occupational exposure in prostate permanent implants with I-125 seeds

    Energy Technology Data Exchange (ETDEWEB)

    Fdez Garcia, J.; Luna, V.; Sancho, J. M. g.; Martinez, J.; Galiano, P. S.; Jimenez, I.; Prada, P.; Juan, G.; Vivanco, J.

    2002-07-01

    Prostate brachytherapy is one of the techniques increasing faster in the environment of the radiotherapy and will probably go on increasing in the future. There are two forms in their use; by means of remote afterloading high dose rate (HDR) with Ir-192 radioactive sources or by means of permanent implant by manual/automatic afterloading of low dose rate (LDR) with seeds of I-125 or Pd-103. Iodine-125 has a half life of 59.4 days and it decays by electron capture with emissions of characteristic photons and electrons. The electrons are absorbed by the titanium wall of the I-125 seed. The principal photon emissions are 27.4 and 31.4 keV X-rays and a 35.5 keV gamma ray. Besides 22.1 and 25.2 keV fluorescent X-rays are also emitted resulting from interactions of the iodine-125 photons with the silver rod. The resulting average photon energy is approximately 27.4 keV. (Author)

  12. SU-E-T-12: A Comparative Dosimetric Study of Pre and Post Prostate Iodine-125 Permanent Seed Implants

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X; Rahimian, J; Goy, B; Cosmatos, H; Qian, Y [Kaiser Permanente, Los Angeles, CA (United States)

    2015-06-15

    Purpose: Post-implant dosimetry has become the gold standard for prostate implant evaluation. The goal of this research is to compare the dosimetry between pre-plan and post-plan in permanent prostate seed implant brachytherapy. Methods: A retrospective study of 91 patients treated with Iodine-125 prostate seed implant between year 2012∼2014 were performed. All plans were created using a VariSeed 8.0 planning system. Pre-plan ultrasound images were acquired using 0.5 cm slice thickness. Post-plan CT images acquired about 1–4 weeks after implant, fused with the preplan ultrasound images. The prostate and urethra contours were generated using the fusion of ultrasound and CT images. Iodine-125 seed source activities varied between 0.382 to 0.414 mCi per seed. The loading patterns varied slightly between patients depending on the prostate size. Statistical analysis of pre and post plans for prostate and urethra volumes, V100%, V150% and D90, and urethra D10 were performed and reported. Results: The pre and post implant average prostate size was 36.90cc vs. 38.58cc; V100% was 98.33% vs. 96.89%; V150% was 47.09% vs. 56.95%; D90 was 116.35Gy vs. 116.12Gy, urethra volume was 1.72cc vs. 1.85cc, urethra D10% was 122.0% vs. 135.35%, respectively. There was no statistically significant difference between the pre and post-plan values for D90(p-value=0.43). However, there are significant differences between other parameters most likely due to post surgical edema; prostate size (p-value= 0.00015); V100% (p-value=3.7803E-07); V150% (p-value=1.49E-09); urethra volume (p-value= 2.77E-06); Urethra D10 (p-value=7.37E-11). Conclusion: The post-plan dosimetry using CT image set showed similar D90 dose coverage to the pre-plan using the ultrasound image dataset. The study showed that our prostate seed implants have consistently delivered adequate therapeutic dose to the prostate while sparing urethra. Future studies to correlate dose versus biochemical response using patients’ PSA

  13. Brachytherapy in early prostate cancer--early experience.

    Science.gov (United States)

    Jose, B O; Bailen, J L; Albrink, F H; Steinbock, G S; Cornett, M S; Benson, D C; Schmied, W K; Medley, R N; Spanos, W J; Paris, K J; Koerner, P D; Gatenby, R A; Wilson, D L; Meyer, R

    1999-01-01

    Use of brachytherapy with radioactive seeds in the management of early prostate cancer is commonly used in the United States. The early experience has been reported from the prostate treatment centers in Seattle for the last 10 years. In this manuscript we are reporting our early experience of 150 radioactive seed implantations in early stage prostate cancer using either Iodine 125 or Palladium 103 seeds. The average age of the patient is 66 years and the median Gleason score is 5.4 with a median PSA of 6. A brief description of the evolution of the treatment of prostate cancer as well as the preparation for the seed implantation using the volume study with ultrasound of the prostate, pubic arch study using CT scan of the pelvis and the complete planning using the treatment planning computers are discussed. We also have described the current technique which is used in our experience based on the Seattle guidelines. We plan a follow-up report with the results of the studies with longer follow-up.

  14. Dosimetric study in iodine-125 seeds for brachytherapy application

    International Nuclear Information System (INIS)

    Zeituni, Carlos Alberto

    2008-01-01

    The demand for iodine-125 seeds for use in brachytherapy treatments has experienced an increase along recent years in Brazil and all over the world. All iodine-125 seed must have its operational parameters measured and/or calculated every time changes in the production process are carried out. A complete dosimetric measurement is very expensive, and it is recommended that this procedure must be repeated at least once a year. Thus, this work developed a methodology for the entire dosimetric process. This methodology is based on the scarce information available in the literature, once almost all the methodology used in large industrial laboratories is commercial secret. The proposed methodology was tested using seeds of Amersham-Oncura-Ge Healthcare, which is the largest seed manufactory in the world. In this new methodology, an automatic reader was employed in order to reduce the time required in the selection process of the TLD-100 dosimeters used and a postprocessing of the obtained spectra was carried out. A total of 142 dosimeters were used and only 29 have been selected using the new methodology. Measurements were performed using slabs of Solid Water RW1 to simulate measuring in the 'water', using three different experimental apparatus and each measurement was repeated at least three times. The TLD-100 calibration was performed using a Dermopan II - Siemens. The measured values showed a good agreement with the ones available in the literature. Finally, these measured values were compared with calculated ones obtained by a semiempirical simulation program, showing a good agreement and, therefore, demonstrating the validity of the proposed methodology regarding dosimetric calculations. (author)

  15. Comparison between methods for fixing radioactive iodine in silver substrate for manufacturing brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Peleias Junior, Fernando S.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M., E-mail: fernandopeleias@gmail.com, E-mail: czeituni@ipen.br, E-mail: elisaros@ipen.br; and others

    2013-07-01

    Cancer is a term used generically to represent a group of more than 100 illnesses, including malignant tumors from different locations. According to World Health Organization (WHO), is a leading cause of death worldwide, accounted for 7.6 million deaths. Prostate cancer is the sixth most common type in the world, representing about 10% of all cases of cancer and its treatment may be by surgery, radiotherapy or even vigilant observation. A method of radiotherapy which has been extensively used in the early and intermediate stages of the illness is brachytherapy, where radioactive seeds are placed inside or next to the area requiring treatment, which reduces the probability of unnecessary damage to surrounding healthy tissues. Currently, the radioactive isotope Iodine-125, adsorbed on silver substrate, is one of the most used in prostate brachytherapy. The present study compares several deposition methods of radioactive Iodine on silver substrate, in order to choose the most suitable one to be implemented at the laboratory of radioactive sources production of IPEN. The methodology used was chosen based on the available infrastructure and experience of the researchers of the institute. Therefore, Iodine-131 was used for testing (same chemical behavior of Iodine -125). Three methods were selected: method 1 (test based on electrodeposition method, developed by David Kubiatowicz) which presented efficiency of 65.16% ; method 2 (chemical reaction based on the method developed by David Kubiatowicz -HCl) which presented efficiency of 70.80%; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) which presented efficiency of 55.80% . Based on the results, the second method is the suggested one to be implemented at the laboratory of radioactive sources production of IPEN. (author)

  16. Comparison between methods for fixing radioactive iodine in silver substrate for manufacturing brachytherapy sources

    International Nuclear Information System (INIS)

    Peleias Junior, Fernando S.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.

    2013-01-01

    Cancer is a term used generically to represent a group of more than 100 illnesses, including malignant tumors from different locations. According to World Health Organization (WHO), is a leading cause of death worldwide, accounted for 7.6 million deaths. Prostate cancer is the sixth most common type in the world, representing about 10% of all cases of cancer and its treatment may be by surgery, radiotherapy or even vigilant observation. A method of radiotherapy which has been extensively used in the early and intermediate stages of the illness is brachytherapy, where radioactive seeds are placed inside or next to the area requiring treatment, which reduces the probability of unnecessary damage to surrounding healthy tissues. Currently, the radioactive isotope Iodine-125, adsorbed on silver substrate, is one of the most used in prostate brachytherapy. The present study compares several deposition methods of radioactive Iodine on silver substrate, in order to choose the most suitable one to be implemented at the laboratory of radioactive sources production of IPEN. The methodology used was chosen based on the available infrastructure and experience of the researchers of the institute. Therefore, Iodine-131 was used for testing (same chemical behavior of Iodine -125). Three methods were selected: method 1 (test based on electrodeposition method, developed by David Kubiatowicz) which presented efficiency of 65.16% ; method 2 (chemical reaction based on the method developed by David Kubiatowicz -HCl) which presented efficiency of 70.80%; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) which presented efficiency of 55.80% . Based on the results, the second method is the suggested one to be implemented at the laboratory of radioactive sources production of IPEN. (author)

  17. Iodine-125 Nilutamide as Novel Radio-therapeutic Ligand for Androgen Receptor in Prostate Cancer

    International Nuclear Information System (INIS)

    Amin, A.M.; EL-Ghany, E.A.; Moustafa, D.

    2009-01-01

    Nilutamide is potent anti-androgen that is used in patients with metastatic prostate carcinoma. The labeling of nilutamide with iodine radioisotopes give an advantage to localize these radionuclides in prostate for imaging and/or therapy depending on the radionuclide used. During this study, nilutamide was labeled successfully with iodine-125 in a neutral ph medium using chloramine-T as oxidizing agent and the radiochemical yield obtained was greater than 96%. The biodistribution of the iodine-125-nilutamide in normal mice indicated the ability of the tracer to bind with specific receptors in prostate and other male organs with 3.5 % at 4 hours post injection. The clearance of the tracer from the blood pool was slow and equal to 40% of the initial blood uptake at 4 hours post injection. The in vivo stability of the tracer was established by the absence of the thyroid uptake. The competition binding was achieved via 1M injection of testosterone and IV injection of non-labeled nilutamide 2 hours before the administration of the tracer. The results referred to a significant reduction in the uptake of the tracer by the prior administration of testosterone and non-labeled nilutamide by 60% and 30%, respectively at 4 hours post injection

  18. SU-F-T-46: The Effect of Inter-Seed Attenuation and Tissue Composition in Prostate 125I Brachytherapy Dose Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, K; Araki, F; Ohno, T [Kumamoto University, Kumamoto, Kumamoto (Japan)

    2016-06-15

    Purpose: To investigate the difference of dose distributions with/without the effect of inter-seed attenuation and tissue compositions in prostate {sup 125}I brachytherapy dose calculations, using Monte Carlo simulations of Particle and Heavy Ion Transport code System (PHITS). Methods: The dose distributions in {sup 125}I prostate brachytherapy were calculated using PHITS for non-simultaneous and simultaneous alignments of STM1251 sources in water or prostate phantom for six patients. The PHITS input file was created from DICOM-RT file which includes source coordinates and structures for clinical target volume (CTV) and organs at risk (OARs) of urethra and rectum, using in-house Matlab software. Photon and electron cutoff energies were set to 1 keV and 100 MeV, respectively. The dose distributions were calculated with the kerma approximation and the voxel size of 1 × 1 × 1 mm{sup 3}. The number of incident photon was set to be the statistical uncertainty (1σ) of less than 1%. The effect of inter-seed attenuation and prostate tissue compositions was evaluated from dose volume histograms (DVHs) for each structure, by comparing to results of the AAPM TG-43 dose calculation (without the effect of inter-seed attenuation and prostate tissue compositions). Results: The dose reduction due to the inter-seed attenuation by source capsules was approximately 2% for CTV and OARs compared to those of TG-43. In additions, by considering prostate tissue composition, the D{sub 90} and V{sub 100} of CTV reduced by 6% and 1%, respectively. Conclusion: It needs to consider the dose reduction due to the inter-seed attenuation and tissue composition in prostate {sup 125}I brachytherapy dose calculations.

  19. Iodine 125 Brachytherapy With Vitrectomy and Silicone Oil in the Treatment of Uveal Melanoma: 1-to-1 Matched Case-Control Series

    International Nuclear Information System (INIS)

    McCannel, Tara A.; McCannel, Colin A.

    2014-01-01

    Purpose: We initially reported the radiation-attenuating effect of silicone oil 1000 centistokes for iodine 125. The purpose of this report was to compare the clinical outcomes in case patients who had iodine 125 brachytherapy with vitrectomy and silicone oil 1000 centistokes with the outcomes in matched control patients who underwent brachytherapy alone. Methods and Materials: Consecutive patients with uveal melanoma who were treated with iodine 125 plaque brachytherapy and vitrectomy with silicone oil with minimum 1-year follow-up were included. Control patients who underwent brachytherapy alone were matched for tumor size, location, and sex. Baseline patient and tumor characteristics and tumor response to radiation, final visual acuity, macular status, central macular thickness by ocular coherence tomography (OCT), cataract progression, and metastasis at last follow-up visit were compared. Surgical complications were also determined. Results: Twenty case patients met the inclusion criteria. The average follow-up time was 22.1 months in case patients and 19.4 months in control patients. The final logMAR vision was 0.81 in case patients and 1.1 in control patients (P=.071); 8 case patients and 16 control patients had abnormal macular findings (P=.011); and the average central macular thickness by OCT was 293.2 μm in case patients and 408.5 μm in control patients (P=.016). Eleven case patients (55%) and 1 control patient (5%) had required cataract surgery at last follow-up (P=.002). Four patients in the case group and 1 patient in the control group experienced metastasis (P=.18). Among the cases, intraoperative retinal tear occurred in 3 patients; total serous retinal detachment and macular hole developed in 1 case patient each. There was no case of rhegmatogenous retinal detachment, treatment failure, or local tumor dissemination in case patients or control patients. Conclusions: With up to 3 years of clinical follow-up, silicone oil during brachytherapy

  20. Iodine 125 Brachytherapy With Vitrectomy and Silicone Oil in the Treatment of Uveal Melanoma: 1-to-1 Matched Case-Control Series

    Energy Technology Data Exchange (ETDEWEB)

    McCannel, Tara A., E-mail: TMcCannel@jsei.ucla.edu; McCannel, Colin A.

    2014-06-01

    Purpose: We initially reported the radiation-attenuating effect of silicone oil 1000 centistokes for iodine 125. The purpose of this report was to compare the clinical outcomes in case patients who had iodine 125 brachytherapy with vitrectomy and silicone oil 1000 centistokes with the outcomes in matched control patients who underwent brachytherapy alone. Methods and Materials: Consecutive patients with uveal melanoma who were treated with iodine 125 plaque brachytherapy and vitrectomy with silicone oil with minimum 1-year follow-up were included. Control patients who underwent brachytherapy alone were matched for tumor size, location, and sex. Baseline patient and tumor characteristics and tumor response to radiation, final visual acuity, macular status, central macular thickness by ocular coherence tomography (OCT), cataract progression, and metastasis at last follow-up visit were compared. Surgical complications were also determined. Results: Twenty case patients met the inclusion criteria. The average follow-up time was 22.1 months in case patients and 19.4 months in control patients. The final logMAR vision was 0.81 in case patients and 1.1 in control patients (P=.071); 8 case patients and 16 control patients had abnormal macular findings (P=.011); and the average central macular thickness by OCT was 293.2 μm in case patients and 408.5 μm in control patients (P=.016). Eleven case patients (55%) and 1 control patient (5%) had required cataract surgery at last follow-up (P=.002). Four patients in the case group and 1 patient in the control group experienced metastasis (P=.18). Among the cases, intraoperative retinal tear occurred in 3 patients; total serous retinal detachment and macular hole developed in 1 case patient each. There was no case of rhegmatogenous retinal detachment, treatment failure, or local tumor dissemination in case patients or control patients. Conclusions: With up to 3 years of clinical follow-up, silicone oil during brachytherapy

  1. The development of a human eye model for ophthalmic iodine-125 brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Mourao, A.P.; Campos, T.P.R.

    2008-01-01

    Full text: Radiotherapy is used to treat malign tumors. Radiotherapy is an alternative to enucleation in ocular tumors. However, the irradiation of ocular region can bring damages due high doses, mainly in the crystalline lens and in the bone tissue in growth phase. Brachytherapy instead of teletherapy looks for reducing doses in the crystalline lens and the adjacent tissues of the ocular globe (orbital region), minimizing side effects. Herein, some encapsulated radioisotopes in radioactive seeds applied to the ocular brachytherapy are available. Thus, a three-dimensional computational voxel model of the ocular region with its heterogeneous tissues, globe and adjacent tissues is developed. This computational model is used to simulate orbital irradiation with radioactive seeds positioned on the sclera surface through the MCNP5 code. The computational simulation allows evaluating how doses are spatially distributed in the orbital volume in treatments with the radioactive seeds of iodine-125. Therefore, the results allow comparing the spatial doses distribution obtained through the MCNP5 simulation for those two distinct types of radioactive seeds. Bench markets from literature validates the proposed simulations. (author)

  2. Dosimetry on ocular brachytherapy with ROPE plaque with iodine125 and palladium-103

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Campos, Tarcisio

    2009-01-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departing absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational model of ocular area was developed to simulate orbital irradiation with ROPES ophthalmologic plaque placed on the sclera surface filled to ten iodine-125 seeds, and palladium-103 seeds. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy. (author)

  3. Towards clinical application of RayStretch for heterogeneity corrections in LDR permanent 125I prostate brachytherapy.

    Science.gov (United States)

    Hueso-González, Fernando; Ballester, Facundo; Perez-Calatayud, Jose; Siebert, Frank-André; Vijande, Javier

    RayStretch is a simple algorithm proposed for heterogeneity corrections in low-dose-rate brachytherapy. It is built on top of TG-43 consensus data, and it has been validated with Monte Carlo (MC) simulations. In this study, we take a real clinical prostate implant with 71 125 I seeds as reference and we apply RayStretch to analyze its performance in worst-case scenarios. To do so, we design two cases where large calcifications are located in the prostate lobules. RayStretch resilience under various calcification density values is also explored. Comparisons against MC calculations are performed. Dose-volume histogram-related parameters like prostate D 90 , rectum D 2cc , or urethra D 10 obtained with RayStretch agree within a few percent with the detailed MC results for all cases considered. The robustness and compatibility of RayStretch with commercial treatment planning systems indicate its applicability in clinical practice for dosimetric corrections in prostate calcifications. Its use during intraoperative ultrasound planning is foreseen. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. PSA bounce after 125I-brachytherapy for prostate cancer as a favorable prognosticator

    International Nuclear Information System (INIS)

    Engeler, Daniel S.; Schwab, Christoph; Schmid, Hans-Peter; Thoeni, Armin F.; Hochreiter, Werner; Prikler, Ladislav; Suter, Stefan; Stucki, Patrick; Schiefer, Johann; Plasswilm, Ludwig; Putora, Paul Martin

    2015-01-01

    Permanent low-dose-rate brachytherapy (BT) with iodine 125 is an established curative treatment for localized prostate cancer. After treatment, prostate-specific antigen (PSA) kinetics may show a transient rise (PSA bounce). Our aim was to investigate the association of PSA bounce with biochemical control. Patients treated with BT in Switzerland were registered in a prospective database. Only patients with a follow-up of at least 2 years were included in our analysis. Clinical follow-up and PSA measurements were assessed after 1.5, 3, 6, and 12 months, and annually thereafter. If PSA increased, additional follow-up visits were scheduled. Cases of PSA bounce were defined as a rise of at least 0.2 ng/ml above the initial PSA nadir with a subsequent decline to or below the initial nadir without treatment. Biochemical failure was defined as a rise to nadir + 2 ng/ml. Between March 2001 and November 2010, 713 patients with prostate cancer undergoing BT with at least 2 years of follow-up were registered. Median follow-up time was 41 months. Biochemical failure occurred in 28 patients (3.9 %). PSA bounce occurred in 173 (24.3 %) patients; only three (1.7 %) patients with PSA bounce developed biochemical failure, in contrast to 25 (4.6 %) patients without previous bounce (p < 0.05). The median time to bounce was 12 months, the median time to biochemical failure was 30 months. The median bounce increase was 0.78 ng/ml. Twenty-eight patients with bounce (16.5 %) had a transient PSA rise of + 2 ng/ml above the nadir. In most cases, an early increase in PSA after BT indicates PSA bounce and is associated with a lower risk of biochemical failure. (orig.) [de

  5. A prospective analysis of long-term quality of life after permanent I-125 brachytherapy for localised prostate cancer

    International Nuclear Information System (INIS)

    Ash, Dan; Bottomley, David; Al-Qaisieh, Bashar; Carey, Brendan; Gould, Kath; Henry, Ann

    2007-01-01

    Background and purpose: To prospectively evaluate long-term urinary, bowel and sexual function after I-125 brachytherapy for localised prostate cancer using patient administered validated Quality of Life (QoL) instruments. Materials and methods: Between March 1995 and March 2004, 673 men underwent brachytherapy and recorded urinary symptoms prospectively using the International Prostate Symptom Score (IPSS). In addition, in a subgroup of 116 patients, the Expanded Prostate Cancer Index Composite (EPIC) was used to record QoL information on urinary, bowel and sexual function before treatment and at regular time intervals for at least two years. Results: Initially, there was a sharp rise in urinary symptoms which was most marked within the first three months. Scores then resolved slowly and returned to within one or two units of pre-treatment level at one year. Subsequently, there was no significant deterioration in urinary symptoms up to nine years following brachytherapy. Few had significant bowel symptoms. Sexual function deteriorated initially and then improved but failed to return to pre-treatment levels by two years. Patients requiring neo-adjuvant hormones experienced significantly more dysfunction. Conclusions: After an initial period of mild to moderate urinary symptoms prostate brachytherapy is well tolerated with relatively little deterioration in long-term quality of life. Long-term reduction in sexual function may be seen particularly in those requiring hormones

  6. Seed-migration detector for embolized seeds to the lung in the context of permanent iodine-125 prostate brachytherapy

    International Nuclear Information System (INIS)

    Morrier, J.; Chretien, M.; Beaulieu, L.

    2008-01-01

    Full text: Purpose: To evaluate the efficacy of a seed-migration detector for embolized seeds to the lung in the context of permanent iodine-125 prostate brachytherapy and to compare its performance to fluoroscopy and to the postoperative chest radiographs generally recommended. Materials and Methods: A low energy gamma scintillation survey meter, Victoreen Model 425-110 was used together with a Victoreen count rate meter (model 190). It was converted to a seed-migration detector by adding a shield on the scintillation probe detection window, following the method proposed by Chen and Blair in 2003 [Med Phys 2003;30:785790]. The detector response to three seeds activities of iodine 125 (0.42, 0.22 and 0.06 mCi) was measured for different source-to-detector distances in air and in water. The detector was used to perform a chest evaluation on 579 patients at their first postoperative visit, for a total of 31 826 seeds. When the detector showed activity around a patients chest, it was confirmed by taking an antero-posterior chest radiograph and by looking at the region with fluoroscopy. Results: 79 patients (13.6%) present at least one embolized seed in the chest area. This account for 94 of the 31 826 seeds, that is a 0.30% seed migration rate. Sixty-eight, seven and four patients had respectively a single, two and three seeds embolization. In three cases, a seed had migrated in the kidney, which was confirmed with a CT scan. Of the 94 seeds, 67 (71%) were visible under fluoroscopy and 55 (59%) appeared on the chest radiograph. Rapid movement of the seeds in the chest area, due to breathing or to a location close to the heart or the diaphragm, makes nine seeds to be visible with fluoroscopy but not on the radiograph. This also explains why twenty-seven seeds were not visible with fluoroscopy neither with radiograph. In comparison to the seed-migration detector, detection based on fluoroscopy would have led to twenty-seven false-negative detections while the radiograph

  7. A comparison study on various low energy sources in interstitial prostate brachytherapy.

    Science.gov (United States)

    Bakhshabadi, Mahdi; Ghorbani, Mahdi; Khosroabadi, Mohsen; Knaup, Courtney; Meigooni, Ali S

    2016-02-01

    Low energy sources are routinely used in prostate brachytherapy. (125)I is one of the most commonly used sources. Low energy (131)Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of (125)I, (103)Pd, and (131)Cs sources in interstitial brachytherapy of prostate. ProstaSeed (125)I brachytherapy source was simulated using MCNPX Monte Carlo code. Additionally, two hypothetical sources of (103)Pd and (131)Cs were simulated with the same geometry as the ProstaSeed (125)I source, while having their specific emitted gamma spectra. These brachytherapy sources were simulated with distribution of forty-eight seeds in a phantom including prostate. The prostate was considered as a sphere with radius of 1.5 cm. Absolute and relative dose rates were obtained in various distances from the source along the transverse and longitudinal axes inside and outside the tumor. Furthermore, isodose curves were plotted around the sources. Analyzing the initial dose profiles for various sources indicated that with the same time duration and air kerma strength, (131)Cs delivers higher dose to tumor. However, relative dose rate inside the tumor is higher and outside the tumor is lower for the (103)Pd source. The higher initial absolute dose in cGy/(h.U) of (131)Cs brachytherapy source is an advantage of this source over the others. The higher relative dose inside the tumor and lower relative dose outside the tumor for the (103)Pd source are advantages of this later brachytherapy source. Based on the total dose the (125)I source has advantage over the others due to its longer half-life.

  8. Focal salvage iodine-125 brachytherapy for prostate cancer recurrences after primary radiotherapy: A retrospective study regarding toxicity, biochemical outcome and quality of life

    International Nuclear Information System (INIS)

    Peters, Max; Maenhout, Metha; Voort van Zyp, Jochem R.N. van der; Moerland, Marinus A.; Moman, Maaike R.; Steuten, Lotte M.G.; Deursen, Marijke J.H. van; Vulpen, Marco van

    2014-01-01

    Purpose: Whole-gland salvage for recurrent prostate cancer (PCa) shows high failure and toxicity rates. Early and adequate localization of recurrences enables focal salvage, thereby potentially improving functional outcomes, while maintaining cancer control. Materials and methods: Retrospective analysis yielded 20 focal salvage I125 brachytherapy patients for locally recurrent PCa after primary radiotherapy. Tumor was defined by multiparametric MRI and correspondence with transrectal biopsies. Dose data were obtained intra-operatively. The tumor was prescribed ⩾144 Gy. Toxicity was scored by the Common Terminology Criteria for Adverse Events version 4 (CTCAE-4). Biochemical failure (BF) was defined using the Phoenix criteria (PSA-nadir + 2.0 ng/ml). Quality of life (QoL) was measured by SF-36 Health Survey and European Organization of Research and Treatment of Cancer (EORTC) C30+3 and PR25 questionnaires. Results: With a median follow-up of 36 months (range 10–45), six patients experienced BF, of which three had no initial response. Grade 3 genitourinary (GU) toxicity occurred in one patient (a urethral stricture). The five previously potent patients retained erectile function. QoL remained decreased with regard to urinary symptoms. Conclusion: Focal salvage I125 brachytherapy showed one grade 3 GU toxicity in the 20 treated patients. Biochemical response and QoL were acceptable

  9. Analysis of the necessary radioprotection procedures in manufacture and transport of iodine-125 sources used in brachytherapy;Analise dos procedimentos de radioprotecao necessarios na manufatura e no transporte de fontes de iodo-125 usadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Souza, C.D.; Hilario, K.F.; Rostelato, M.E.C.M. [Instituto de Pesquisas Energeticas e Nucleares (CTR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes

    2009-07-01

    The estimates for the year 2009 show that 466,730 new cancer cases will occur in Brazil. Prostate cancer is the second most incident type. Brachytherapy, a type of radiotherapy, with Iodine-125 sources are an important form of treatment for this kind of cancer. The Energy and Nuclear Research Institute IPEN-CNEN/SP created a project to develop a national prototype of these sources and is implementing a facility for local production. The seeds manufacture in Brazil will allow to diminish the treatment cost and make it possible for a larger number of patients. This study aim to evaluate the procedures for transport and radiation protection requirements for employees with imported sources in order to tailor them for use in the new laboratory. Before being sent to hospitals, the packages are monitored by a radioprotection supervisor. Despite Iodine-125 presents low-energy photons, about 29 keV, local and personal dosimeters are used during transport, as described in the standards. The results showed no significant contamination or occupational exposure, validating the existing method. The transport procedure is correct, according to the regulations. For local production, new detectors should be implemented. (author)

  10. Ultrasonically guided 125iodine seed implantation with external radiation in management of localized prostatic carcinoma

    DEFF Research Database (Denmark)

    Iversen, P; Bak, M; Juul, N

    1989-01-01

    Thirty-three patients with localized prostatic carcinoma (16 poorly differentiated) were treated with transperineal 125Iodine seed implantation (160 Gy) guided by transrectal ultrasonography and subsequent external beam irradiation (47.4 Gy). The observation time was six to sixty-eight months...... with a median follow-up of thirty-five months. Median change in prostatic volume was a reduction of 35 percent. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after one to two years, revealing still malignant histology in 12 (48%). Development of distant metastases occurred...

  11. Low dose rate Ir-192 interstitial brachytherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Yosuke; Dokiya, Takushi; Yorozu, Atsunori; Suzuki, Takayuki; Saito, Shiro; Monma, Tetsuo; Ohki, Takahiro [National Tokyo Medical Center (Japan); Murai, Masaru; Kubo, Atsushi

    2000-04-01

    From December 1997 through January 1999, fifteen prostatic cancer patients were treated with low dose rate Ir-192 interstitial brachytherapy using TRUS and perineal template guidance without external radiotherapy. Up to now, as no apparent side effects were found, the safety of this treatment is suggested. In the future, in order to treat prostatic cancer patients with interstitial brachytherapy using I-125 or Pd-103, more investigation for this low dose rate Ir-192 interstitial brachytherapy is needed. (author)

  12. Dosimetry on ocular brachytherapy with ROPES plaque with Iodine-125 and Palladium-103 seeds

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Campos, Tarcisio P.R.

    2010-01-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departuring absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational model of ocular area was developed to simulate orbital irradiation with ROPES ophthalmologic plaque placed on the sclera surface filled to ten iodine-125 seeds, and palladium-103 seeds. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy. (author)

  13. Development of prostate voxel models for brachytherapy treatment

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Adriano M.; Reis, Lucas P.; Grynberg, Suely E., E-mail: amsantos@cdtn.b [Center for Development of Nuclear Technology (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The tools developed recently in the areas of computer graphics and animation movies to computer games allow the creation of new voxel anthropomorphic phantoms with better resolution and thus, more anatomical details. These phantoms can be used in nuclear applications, especially in radiation protection for estimating doses in cases of occupational or accidental radioactive incidents, and in medical and biological applications. For dose estimates, the phantoms are coupled to a Monte Carlo code, which will be responsible for the transport of radiation in this environment. This study aimed to develop a computational tool to estimate the isodose curves in the prostate after brachytherapy seed implants. For this, we have created a model called FANTPROST in the shape of a 48 mm side cube, with a standard prostate inserted in the center of this cube with different distributions of brachytherapy seeds in this volume. The prostate, according to this model, was obtained from the phantom voxels MASH2 developed by Numerical Dosimetry Group, Department of Nuclear Energy - Federal University of Pernambuco. The modeling of the seeds, added to FANTPROST, was done through the use of geometric information of Iodine-125 Amersham 6711 commercial seed. The simulations were performed by the code MCNP5 for spatial distributions containing different amounts of seeds within the FANTPROST. The obtained curves allowed an estimation of the behavior of the maximum dose that decreases with distance, showing that this tool can be used for a more accurate analysis of the effects produced by the presence of such seeds in the prostate and its vicinity. (author)

  14. A comparison study on various low energy sources in interstitial prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Mahdi Bakhshabadi

    2016-02-01

    Full Text Available Purpose: Low energy sources are routinely used in prostate brachytherapy. 125 I is one of the most commonly used sources. Low energy 131 Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of 125 I, 103 Pd, and 131 Cs sources in interstitial brachytherapy of prostate. Material and methods: ProstaSeed 125 I brachytherapy source was simulated using MCNPX Monte Carlo code. Additionally, two hypothetical sources of 103 Pd and 131 Cs were simulated with the same geometry as the ProstaSeed 125 I source, while having their specific emitted gamma spectra. These brachytherapy sources were simulated with distribution of forty-eight seeds in a phantom including prostate. The prostate was considered as a sphere with radius of 1.5 cm. Absolute and relative dose rates were obtained in various distances from the source along the transverse and longitudinal axes inside and outside the tumor. Furthermore, isodose curves were plotted around the sources. Results : Analyzing the initial dose profiles for various sources indicated that with the same time duration and air kerma strength, 131 Cs delivers higher dose to tumor. However, relative dose rate inside the tumor is higher and outside the tumor is lower for the 103 Pd source. Conclusions : The higher initial absolute dose in cGy/(h.U of 131 Cs brachytherapy source is an advantage of this source over the others. The higher relative dose inside the tumor and lower relative dose outside the tumor for the 103 Pd source are advantages of this later brachytherapy source. Based on the total dose the 125 I source has advantage over the others due to its longer half-life.

  15. Permanent 125I-seed prostate brachytherapy: early prostate specific antigen value as a predictor of PSA bounce occurrence

    Directory of Open Access Journals (Sweden)

    Mazeron Renaud

    2012-03-01

    Full Text Available Abstract Purpose To evaluate predictive factors for PSA bounce after 125I permanent seed prostate brachytherapy and identify criteria that distinguish between benign bounces and biochemical relapses. Materials and methods Men treated with exclusive permanent 125I seed brachytherapy from November 1999, with at least a 36 months follow-up were included. Bounce was defined as an increase ≥ 0.2 ng/ml above the nadir, followed by a spontaneous return to the nadir. Biochemical failure (BF was defined using the criteria of the Phoenix conference: nadir +2 ng/ml. Results 198 men were included. After a median follow-up of 63.9 months, 21 patients experienced a BF, and 35.9% had at least one bounce which occurred after a median period of 17 months after implantation (4-50. Bounce amplitude was 0.6 ng/ml (0.2-5.1, and duration was 13.6 months (4.0-44.9. In 12.5%, bounce magnitude exceeded the threshold defining BF. Age at the time of treatment and high PSA level assessed at 6 weeks were significantly correlated with bounce but not with BF. Bounce patients had a higher BF free survival than the others (100% versus 92%, p = 0,007. In case of PSA increase, PSA doubling time and velocity were not significantly different between bounce and BF patients. Bounces occurred significantly earlier than relapses and than nadir + 0.2 ng/ml in BF patients (17 vs 27.8 months, p Conclusion High PSA value assessed 6 weeks after brachytherapy and young age were significantly associated to a higher risk of bounces but not to BF. Long delays between brachytherapy and PSA increase are more indicative of BF.

  16. Exposure of treating physician to radiation during prostate brachytherapy using iodine-125 seeds. Dose measurements on both hands with thermoluminescence dosimeters

    International Nuclear Information System (INIS)

    Schiefer, Hans; Seelentag, Wolf; Plasswilm, Ludwig; Ries, Gerhard; Toggenburg, Friedrich von; Lenggenhager, Cornelius; Schmid, Hans-Peter; Leippold, Thomas; Engeler, Daniel; Prikler, Ladislav; Krusche, Bernd; Roth, Jakob

    2009-01-01

    Background and purpose: only sparse reports have been made about radiation exposure of the treating physician during prostate seed implantation. Therefore, thermoluminescence dosimeter (TLD) measurements on the index fingers and the backs of both hands were conducted. Material and methods: stranded iodine-125 seeds with a mean apparent activity of 27.4 MBq per seed were used. During application, the treating physician manipulated the loaded needle with the index fingers, partially under fluoroscopic control. Four physicians with varying experience treated 24 patients. The radiation exposure was determined with TLD-100 chips attached to the index fingertips and the backs of hands. Radiation exposure was correlated with the physician's experience. Results: the average brachytherapy duration by the most experienced physician was 19.2 min (standard deviation σ = 1.2 min; novices: 34.8 min [σ = 10.2 min]). The mean activity was 1,703 MBq (σ = 123 MBq), applied with 16.3 needles (σ = 2.5 needles; novices: 1,469 MBq [σ = 229 MBq]; 16.8 needles [σ = 2.3 needles ]). The exposure of the finger of the ''active hand'' and the back of the hand amounted to 1.31 mSv (σ = 0.54 mSv) and 0.61 mSv (σ = 0.23 mSv), respectively (novices: 2.07 mSv [σ = 0.86 mSv] and 1.05 mSv [σ = 0.53 mSv]). Conclusion: if no other radiation exposure needs to be considered, an experienced physician can perform about 400 applications per year without exceeding the limit of 500 mSv/year; for novices, the corresponding figure is about 200. (orig.)

  17. Prostate biopsy after definitive treatment by interstitial iodine 125 implant or external beam radiation therapy

    International Nuclear Information System (INIS)

    Schellhammer, P.F.; el-Mahdi, A.M.; Higgins, E.M.; Schultheiss, T.E.; Ladaga, L.E.; Babb, T.J.

    1987-01-01

    The response to definitive radiation therapy of localized carcinoma of the prostate by iodine 125 implantation or external beam radiotherapy was monitored by examining specimens from biopsies performed after treatment. We analyzed 126 biopsy specimens obtained 18 months or more after treatment: 71 were obtained from 109 patients treated by iodine 125 and 55 from 197 patients treated by external beam radiotherapy. Thereafter, the disease status of these patients was examined at minimum 3-year intervals. No significant statistical difference was found between the negative specimen rates of the 2 treatment modalities: 46 of 71 (65 per cent) after iodine 125 implantation and 39 of 55 (71 per cent) after external beam radiotherapy were negative. To analyze the predictive value of biopsy results 103 patients whose prostatic examination results were normal at biopsy or who showed regression of tumor size and tumor induration after radiation were evaluated. The biopsy results from all patients were combined for analysis. Of 77 patients with negative biopsy specimens 16 (21 per cent) have had recurrent disease, compared to 17 of 26 (65 per cent) with positive biopsy specimens (p equals 0.00005). Of the 77 patients with negative biopsy specimens 7 (9 per cent) had local disease recurrence, compared to 12 of 26 (46 per cent) with a positive biopsy specimen (p equals 0.0001). The value of a positive specimen to predict failure remained significant with patients stratified by pre-treatment clinical stage and grade of the disease. Our results show that patients with positive specimens from the prostate who had been judged clinically by rectal examination to have responded to radiation therapy had a significantly increased incidence of local and distant failure compared to patients who had negative biopsy specimens

  18. First symposium seed implant 125I and high rate of prostate

    International Nuclear Information System (INIS)

    2012-01-01

    The First symposium seed implant 125 I and high rate of prostate, was organized by the Marie Curie Foundation, between the 12 to april 2012, in the Cordoba city of Argentina. In this event were presented several documents in different topics: patients selection for impacts of 125 I seeds; high doses radiation in radiotherapy; brachytherapy for prostate cancer; prostate implant technique with 125 I seeds; implant dosimetric aspects; radioprotection of 125 I seeds.

  19. DNA-PKcs Expression Is a Predictor of Biochemical Recurrence After Permanent Iodine 125 Interstitial Brachytherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Molina, Sarah; Guerif, Stéphane; Garcia, Alexandre; Debiais, Céline; Irani, Jacques; Fromont, Gaëlle

    2016-01-01

    Purpose: Predictive factors for biochemical recurrence (BCR) in localized prostate cancer (PCa) after brachytherapy are insufficient to date. Cellular radiosensitivity depends on DNA double-strand breaks, mainly repaired by the nonhomologous end-joining (NHEJ) system. We analyzed whether the expression of NHEJ proteins can predict BCR in patients treated by brachytherapy for localized PCa. Methods and Materials: From 983 PCa cases treated by brachytherapy between March 2000 and March 2012, 167 patients with available biopsy material suitable for in situ analysis were included in the study. The median follow-up time was 47 months. Twenty-nine patients experienced BCR. All slides were reviewed to reassess the Gleason score. Expression of the key NHEJ proteins DNA-PKcs, Ku70, and Ku80, and the proliferation marker Ki67, was studied by immunohistochemistry performed on tissue microarrays. Results: The Gleason scores after review (P=.06) tended to be associated with BCR when compared with the score initially reported (P=.74). Both the clinical stage (P=.02) and the pretreatment prostate-specific antigen level (P=.01) were associated with biochemical failure. Whereas the expression of Ku80 and Ki67 were not predictive of relapse, positive DNA-PKcs nuclear staining (P=.003) and higher Ku70 expression (P=.05) were associated with BCR. On multivariate analysis, among pretreatment variables, only DNA-PKcs (P=.03) and clinical stage (P=.02) remained predictive of recurrence. None of the patients without palpable PCa and negative DNA-PKcs expression experienced biochemical failure, compared with 32% of men with palpable and positive DNA-PKcs staining that recurred. Conclusions: Our results suggest that DNA-PKcs could be a predictive marker of BCR after brachytherapy, and this might be a useful tool for optimizing the choice of treatment in low-risk PCa patients.

  20. DNA-PKcs Expression Is a Predictor of Biochemical Recurrence After Permanent Iodine 125 Interstitial Brachytherapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Molina, Sarah [Department of Pathology, INSERM UMR1069, CHU/Université de Tours, Tours (France); Department of Radiation Oncology, CHU/Université de Poitiers, Poitiers (France); Guerif, Stéphane; Garcia, Alexandre [Department of Radiation Oncology, CHU/Université de Poitiers, Poitiers (France); Debiais, Céline [Department of Pathology, CHU/Université de Poitiers, Poitiers (France); Irani, Jacques [Department of Urology, CHU/Université de Poitiers, Poitiers (France); Fromont, Gaëlle, E-mail: gaelle.fromont-hankard@univ-tours.fr [Department of Pathology, INSERM UMR1069, CHU/Université de Tours, Tours (France)

    2016-07-01

    Purpose: Predictive factors for biochemical recurrence (BCR) in localized prostate cancer (PCa) after brachytherapy are insufficient to date. Cellular radiosensitivity depends on DNA double-strand breaks, mainly repaired by the nonhomologous end-joining (NHEJ) system. We analyzed whether the expression of NHEJ proteins can predict BCR in patients treated by brachytherapy for localized PCa. Methods and Materials: From 983 PCa cases treated by brachytherapy between March 2000 and March 2012, 167 patients with available biopsy material suitable for in situ analysis were included in the study. The median follow-up time was 47 months. Twenty-nine patients experienced BCR. All slides were reviewed to reassess the Gleason score. Expression of the key NHEJ proteins DNA-PKcs, Ku70, and Ku80, and the proliferation marker Ki67, was studied by immunohistochemistry performed on tissue microarrays. Results: The Gleason scores after review (P=.06) tended to be associated with BCR when compared with the score initially reported (P=.74). Both the clinical stage (P=.02) and the pretreatment prostate-specific antigen level (P=.01) were associated with biochemical failure. Whereas the expression of Ku80 and Ki67 were not predictive of relapse, positive DNA-PKcs nuclear staining (P=.003) and higher Ku70 expression (P=.05) were associated with BCR. On multivariate analysis, among pretreatment variables, only DNA-PKcs (P=.03) and clinical stage (P=.02) remained predictive of recurrence. None of the patients without palpable PCa and negative DNA-PKcs expression experienced biochemical failure, compared with 32% of men with palpable and positive DNA-PKcs staining that recurred. Conclusions: Our results suggest that DNA-PKcs could be a predictive marker of BCR after brachytherapy, and this might be a useful tool for optimizing the choice of treatment in low-risk PCa patients.

  1. Study of two different radioactive sources for prostate brachytherapy treatment

    International Nuclear Information System (INIS)

    Pereira Neves, Lucio; Perini, Ana Paula; Souza Santos, William de; Caldas, Linda V.E.; Belinato, Walmir

    2015-01-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a 192 Ir and a 125 I radioactive sources. The 192 Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The 125 I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of 125 I and one of 192 Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the 192 Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the 125 I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  2. Study of two different radioactive sources for prostate brachytherapy treatment

    Energy Technology Data Exchange (ETDEWEB)

    Pereira Neves, Lucio; Perini, Ana Paula [Instituto de Fisica, Universidade Federal de Uberlandia, Caixa Postal 593, 38400-902, Uberlandia, MG (Brazil); Souza Santos, William de; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, IPENCNEN/SP, Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, 05508-000 Sao Paulo, SP (Brazil); Belinato, Walmir [Departamento de Ensino, Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia, Campus Vitoria da Conquista, Zabele, Av. Amazonas 3150, 45030-220 Vitoria da Conquista, BA (Brazil)

    2015-07-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a {sup 192}Ir and a {sup 125}I radioactive sources. The {sup 192}Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The {sup 125}I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of {sup 125}I and one of {sup 192}Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the {sup 192}Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the {sup 125}I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  3. The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

    Directory of Open Access Journals (Sweden)

    Seyed Milad Vahabi

    2016-09-01

    Full Text Available Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the legs on dose calculations. Materials and Methods The doses to organs of interest were calculated using MCNPX code and ORNL (Oak Ridge National Laboratory phantom. Results Doses to the prostate as a source of radiation for 125I, 103Pd, and 131Cs were approximately 108.9, 97.7, and 81.5 Gy, respectively. Bladder, sigmoid colon, and testes received higher doses than other organs due to proximity to the prostate. Differences between the doses when tallying with the legs intact and with the legs voided were significant for testes, sigmoid colon contents, and sigmoid colon wall because of their proximity to the prostate. There was also a good consistency between our results and the data published by Montefiore Medical Center and Albert Einstein College of Medicine for the prostate. Conclusion Scattering from leg region had a significant effect on doses to testes, sigmoid colon contents, and sigmoid colon wall in the pelvic region, and prostate and the other organs were unaffected. Brachytherapy treatment plans using 131Cs seeds allow for better sparing of critical tissues, with a comparable number of, or fewer, seeds required, compared to 125I seeds.

  4. Comparison of Dosimetric and Biologic Effective Dose Parameters for Prostate and Urethra Using 131Cs and 125I for Prostate Permanent Implant Brachytherapy

    International Nuclear Information System (INIS)

    Sahgal, Arjun; Jabbari, Siavash; Chen, Josephine; Pickett, Barbie; Roach, Mack; Weinberg, Vivian; Hsu, I-C.; Pouliot, Jean

    2008-01-01

    Purpose: To compare the urethral and prostate absolute and biologic effective doses (BEDs) for 131 Cs and 125 I prostate permanent implant brachytherapy (PPI). Methods and Materials: Eight previously implanted manually planned 125 I PPI patients were replanned manually with 131 Cs, and re-planned using Inverse Planning Simulated Annealing. 131 Cs activity and the prescribed dose (115 Gy) were determined from that recommended by IsoRay. The BED was calculated for the prostate and urethra using an α/β ratio of 2 and was also calculated for the prostate using an α/β ratio of 6 and a urethral α/β ratio of 2. The primary endpoints of this study were the prostate D 90 BED (pD 90 BED) and urethral D 30 BED normalized to the maximal potential prostate D 90 BED (nuD 30 BED). Results: The manual plan comparison (α/β = 2) yielded no significant difference in the prostate D 90 BED (median, 192 Gy 2 for both isotopes). No significant difference was observed for the nuD 30 BED (median, 199 Gy 2 and 202 Gy 2 for 125 I and 131 Cs, respectively). For the inverse planning simulated annealing plan comparisons (α/β 2), the prostate D 90 BED was significantly lower with 131 Cs than with 125 I (median, 177 Gy 2 vs. 187 Gy 2 , respectively; p = 0.01). However, the nuD 30 BED was significantly greater with 131 Cs than with 125 I (median, 192 Gy 2 vs. 189 Gy 2 , respectively; p = 0.01). Both the manual and the inverse planning simulated annealing plans resulted in a significantly lower prostate D 90 BED (p = 0.01) and significantly greater nuD 30 BED for 131 Cs (p = 0.01), compared with 125 I, when the prostate α/β ratio was 6 and the urethral α/β ratio was 2. Conclusion: This report highlights the controversy in comparing the dose to both the prostate and the organs at risk with different radionuclides

  5. Influence of radioactive sources discretization in the Monte Carlo computational simulations of brachytherapy procedures: a case study on the procedures for treatment of prostate cancer

    International Nuclear Information System (INIS)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson; Costa, Kleber Souza Silva; Lima, Fernando Roberto de Andrade

    2011-01-01

    Radiotherapy computational simulation procedures using Monte Carlo (MC) methods have shown to be increasingly important to the improvement of cancer fighting strategies. One of the biases in this practice is the discretization of the radioactive source in brachytherapy simulations, which often do not match with a real situation. This study had the aim to identify and to measure the influence of radioactive sources discretization in brachytherapy MC simulations when compared to those that do not present discretization, using prostate brachytherapy with Iodine-125 radionuclide as model. Simulations were carried out with 108 events with both types of sources to compare them using EGSnrc code associated to MASH phantom in orthostatic and supine positions with some anatomic adaptations. Significant alterations were found, especially regarding bladder, rectum and the prostate itself. It can be concluded that there is a need to discretized sources in brachytherapy simulations to ensure its representativeness. (author)

  6. On the use of Kodak CR film for quality assurance of needle loading in I-125 seed prostate brachytherapy.

    Science.gov (United States)

    Fog, L S; Nicholls, R; van Doom, T

    2007-09-01

    Low dose rate brachytherapy using implanted I-125 seeds as a monotherapy for prostate cancer is now in use in many hospitals. In contrast to fractionated brachytherapy treatments, where the effect of incorrect positioning of the source in one treatment fraction can be diminished by correcting the position in subsequent fractions, the I-125 seed implant is permanent, making correct positioning of the seeds in the prostate essential. The seeds are inserted into the prostate using needles. Correct configuration of seeds in the needles is essential in order to deliver the planned treatment. A comparison of an autoradiograph obtained by exposing film to the seed-loaded needles with the patient treatment plan is a valuable quality assurance tool. However, the time required to sufficiently expose Kodak XOMAT V film, currently used in this department is significant. This technical note presents the use of Kodak CR film for acquisition of the radiograph. The digital radiograph can be acquired significantly faster, has superior signal-to-noise ratio and contrast and has the usual benefits of digital film, e.g. a processing time which is shorter than that required for non-digital film, the possibility of image manipulation, possibility of paper printing and electronic storage.

  7. Study and development of methodology for radioactive iodine fixation in polymeric substrate for manufacturing sources used in brachytherapy

    International Nuclear Information System (INIS)

    Rodrigues, Bruna T.; Souza, Carla D.; Benega, Marcos A.G. and others

    2014-01-01

    According global estimates of Globocan 2012 project of the International Agency for Research of Cancer, of the World Health Organization, there were 14,1 million new cases of cancer and a total of 8,2 million deaths from cancer. Also show that in 2030, the overall load will be 21,4 million new cases and 13,2 million cancer deaths. One of the prostate cancer therapy is brachytherapy, used in early and middle stages of the disease. It is made with the introduction of seeds with radioactive material within the tumor or in nearby regions, affecting the minimum surrounding tissues. The aim of this work is the study and developing the deposition of radioactive iodine on the polymeric substrate method, and an analysis relating the efficiency of the method to implementation in the laboratory of brachytherapy from IPEN. Iodine-125 is adsorbed on an epoxy resin solution. The objective of this study is to offer a new proposal for seeds. The results will give the data for the radiation protection and the procedures for radioactive waste management

  8. Establishing High-Quality Prostate Brachytherapy Using a Phantom Simulator Training Program

    Energy Technology Data Exchange (ETDEWEB)

    Thaker, Nikhil G. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kudchadker, Rajat J. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Swanson, David A. [Department of Urology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Albert, Jeffrey M. [Department of Radiation Oncology, Banner Health, Loveland/Greeley, Colorado (United States); Mahmood, Usama; Pugh, Thomas J.; Boehling, Nicholas S. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Bruno, Teresa L. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Prestidge, Bradley R. [Department of Radiation Oncology, Bon Secours Health System, Norfolk, Virginia (United States); Crook, Juanita M. [Department of Radiation Oncology, Cancer Center for the Southern Interior, Kelowna, British Columbia (Canada); Cox, Brett W.; Potters, Louis [Department of Radiation Medicine, North Shore-LIJ Health System, New Hyde Park, New York (United States); Moran, Brian J. [Chicago Prostate Center, Westmont, Illinois (United States); Keyes, Mira [Department of Radiation Oncology, British Columbia Cancer Agency, Vancouver Center, Vancouver, British Columbia (Canada); Kuban, Deborah A. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Frank, Steven J., E-mail: sjfrank@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2014-11-01

    Purpose: To design and implement a unique training program that uses a phantom-based simulator to teach the process of prostate brachytherapy (PB) quality assurance and improve the quality of education. Methods and Materials: Trainees in our simulator program were practicing radiation oncologists, radiation oncology residents, and fellows of the American Brachytherapy Society. The program emphasized 6 core areas of quality assurance: patient selection, simulation, treatment planning, implant technique, treatment evaluation, and outcome assessment. Using the Iodine 125 ({sup 125}I) preoperative treatment planning technique, trainees implanted their ultrasound phantoms with dummy seeds (ie, seeds with no activity). Pre- and postimplant dosimetric parameters were compared and correlated using regression analysis. Results: Thirty-one trainees successfully completed the simulator program during the period under study. The mean phantom prostate size, number of seeds used, and total activity were generally consistent between trainees. All trainees met the V100 >95% objective both before and after implantation. Regardless of the initial volume of the prostate phantom, trainees' ability to cover the target volume with at least 100% of the dose (V100) was not compromised (R=0.99 pre- and postimplant). However, the V150 had lower concordance (R=0.37) and may better reflect heterogeneity control of the implant process. Conclusions: Analysis of implants from this phantom-based simulator shows a high degree of consistency between trainees and uniformly high-quality implants with respect to parameters used in clinical practice. This training program provides a valuable educational opportunity that improves the quality of PB training and likely accelerates the learning curve inherent in PB. Prostate phantom implantation can be a valuable first step in the acquisition of the required skills to safely perform PB.

  9. Establishing High-Quality Prostate Brachytherapy Using a Phantom Simulator Training Program

    International Nuclear Information System (INIS)

    Thaker, Nikhil G.; Kudchadker, Rajat J.; Swanson, David A.; Albert, Jeffrey M.; Mahmood, Usama; Pugh, Thomas J.; Boehling, Nicholas S.; Bruno, Teresa L.; Prestidge, Bradley R.; Crook, Juanita M.; Cox, Brett W.; Potters, Louis; Moran, Brian J.; Keyes, Mira; Kuban, Deborah A.; Frank, Steven J.

    2014-01-01

    Purpose: To design and implement a unique training program that uses a phantom-based simulator to teach the process of prostate brachytherapy (PB) quality assurance and improve the quality of education. Methods and Materials: Trainees in our simulator program were practicing radiation oncologists, radiation oncology residents, and fellows of the American Brachytherapy Society. The program emphasized 6 core areas of quality assurance: patient selection, simulation, treatment planning, implant technique, treatment evaluation, and outcome assessment. Using the Iodine 125 ( 125 I) preoperative treatment planning technique, trainees implanted their ultrasound phantoms with dummy seeds (ie, seeds with no activity). Pre- and postimplant dosimetric parameters were compared and correlated using regression analysis. Results: Thirty-one trainees successfully completed the simulator program during the period under study. The mean phantom prostate size, number of seeds used, and total activity were generally consistent between trainees. All trainees met the V100 >95% objective both before and after implantation. Regardless of the initial volume of the prostate phantom, trainees' ability to cover the target volume with at least 100% of the dose (V100) was not compromised (R=0.99 pre- and postimplant). However, the V150 had lower concordance (R=0.37) and may better reflect heterogeneity control of the implant process. Conclusions: Analysis of implants from this phantom-based simulator shows a high degree of consistency between trainees and uniformly high-quality implants with respect to parameters used in clinical practice. This training program provides a valuable educational opportunity that improves the quality of PB training and likely accelerates the learning curve inherent in PB. Prostate phantom implantation can be a valuable first step in the acquisition of the required skills to safely perform PB

  10. Comparative dosimetry of prostate brachytherapy with I-125 and Pd-103 seeds via SISCODES/MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Bruno Machado; Falcao, Patricia Lima, E-mail: bmtrindade@yahoo.com [Nucleo de Radiacoes Ionizantes - Universidade Federal de Minas Gerais (NRI/UFMG), Belo Horizonte, MG (Brazil); Christovao, Marilia Tavares [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Trindade, Daniela de Fatima Maia [Centro Universitario Una, Belo Horizonte, MG (Brazil); Campos, Tarcisio Passos Ribeiro de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2012-09-15

    Objective: The present paper is aimed at presenting a comparative dosimetric study of prostate brachytherapy with I-125 and Pd-103 seeds. Materials and Methods: A protocol for both implants with 148 seeds was simulated on a heterogeneous three-dimensional pelvic phantom by means of the SISCODES/MCNP5 codes. Dose-volume histograms on prostate, rectum and bladder, dose indexes D10, D30, D90, D0.5cc, D2cc and D7cc, and representations of the spatial dose distribution were evaluated. Results: For a D90 index equivalent to the prescription dose, the initial activity of each I-125 seed was calculated as 0.42 mCi and of Pd-103 as 0.94 mCi. The maximum dose on the urethra was 90% and 108% of the prescription dose for I-125 and Pd-103, respectively. The D2cc for I-125 was 30 Gy on the rectum and 127 Gy on the bladder; for Pd-103 was 29 Gy on the rectum and 189 Gy on the bladder. The D10 on the pubic bone was 144 Gy for I-125 and 66 Gy for Pd-103. Conclusion: The results indicate that Pd-103 and I-125 implants could deposit the prescribed dose on the target volume. Among the findings of the present study, there is an excessive radiation exposure of the pelvic bones, particularly with the I-125 protocol. (author)

  11. Segmental Urethral Dosimetry and Urinary Toxicity in Patients With No Urinary Symptoms Before Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Thomas, Carys; Keyes, Mira; Liu, Mitchell; Moravan, Veronika

    2008-01-01

    Purpose: To determine whether segmental urethral dosimetry is predictive for the degree of urinary morbidity after prostate brachytherapy in patients with no urinary symptoms before prostate brachytherapy. Methods and Materials: Between May 2000 and November 2005, 1,107 patients underwent iodine-125 monotherapy with urethral sparing techniques. A total of 166 patients fulfilled the selection criteria: baseline (International Prostate Symptom Score) IPSS ≤5, no androgen deprivation therapy, and prostate ultrasound planning volumes (PUTV) <45 mL. The median follow-up was 44 months. Urinary morbidity was defined by maximum increase in IPSS, time to IPSS resolution, maximum Radiation Therapy Oncology Group (RTOG) score, time to RTOG resolution, and urinary retention. Surrogate deviated urethra was contoured and doses calculated at the base, mid-prostate, apex, and urogenital diaphragm. Univariate and multivariate analysis was used to evaluate urethral and prostate dosimetry, age, PUTV, and number of needles for their association with urinary morbidity. Results: Urethral dose was fairly constant in all urethra segments except prostate base, where the variation in does was large. On multivariate analysis, higher urethral base D50, V100, and larger PUTV were predictive for higher maximum increase in IPSS. Higher urethral base V100 and larger PUTV predicted for prolonged IPSS resolution. Higher urethral base D50 and larger needle number predicted for longer RTOG resolution. Higher urethral base V100 predicted for RTOG ≥2 toxicity. Conclusions: Radiation dose to the urethral base, larger PUTV, and needle number, predicted for increased urinary toxicity after prostate brachytherapy. Correlation between urinary morbidity and urethral base dosimetry may reflect a large variation in urethral dose observed at the prostate base

  12. Comparison between methods for fixing radioactive iodine in silver substrate for manufacturing brachytherapy sources

    International Nuclear Information System (INIS)

    Souza, Carla Daruich

    2012-01-01

    Among the different ways to treat prostate cancer, brachytherapy with iodine- 125 seeds is an option that provides good results and fewer side effects. In the present study several deposition methods of radioactive iodine in a silver substrate were compared in order to choose the most suitable alternative for the routine production to be implemented at IPEN's laboratory. The methodology used was chosen based on the available infrastructure and experience of the researchers present. Therefore, the 131 I was used for testing (same chemical behavior as 131 I). Four methods were selected: Method 1 (test based on electrodeposition method developed by D.Kubiatowicz) presented 65.16% efficiency; Method 2 (chemical reaction based on the method developed by D. Kubiatowicz - HCl) with the result of 70.80% efficiency; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) with 55.80% efficiency; Method 4 (IQ-IPEN) resulted in 99% efficiency. Since this method has more radioactive material fixation (which represents virtually the entire cost of the seed), the final price is the cheapest. This method is the suggested one to be implemented in the IPEN's laboratory for brachytherapy sources production. Besides, the method is the fasted one. (author)

  13. Study and methodologies for fixing epoxy resin in radioactive sources used for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Bruna T.; Rostelato, Maria E.C.M.; Souza, Carla D.; Tozetti, Cíntia A.; Zeituni, Carlos A.; Nogueira, Beatriz R.; Silva, José T.; Júnior, Dib K.; Fernandes, Vagner; Souza, Raquel V.; Abreu, Rodrigo T., E-mail: bteigarodrigues@gmail.com, E-mail: elisaros@ipen.br, E-mail: carladdsouza@yahoo.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Universidade de São Paulo (USP), SP (Brazil)

    2017-07-01

    The World Health Organization (WHO) estimates that the number of new cancer cases worldwide will reach 15 million by 2020. The disease is already the second leading cause of death worldwide, being behind only cardiovascular disease. It is unquestionable that it is a public health problem, especially among developing countries. Prostate cancer is the most common among men, approximately 28.6%. The choice of type of treatment for prostate cancer should consider several factors such as: tumor size and extent, apparent aggressiveness (pathological characteristics), age, health. Among the methods applied, brachytherapy has been used in the initial and intermediate stages of the disease. Brachytherapy is a safe and effective treatment for localized prostate cancer. Brachytherapy is a form of radiotherapy in which radioactive seeds are placed in contact with or within the organ being treated. This technique allows a large dose of radiation to be released only on the target tumor that protects healthy surrounding tissues. Sources may have different shapes and sizes, but the one used for prostate cancer is usually 4.5 mm in length and 0.8 mm in diameter. About 80 to 120 seeds can be used per patient. Iodine-125 is the radioisotope most used in brachytherapy of the prostate, it emits 35,49keV X-rays in 100% of the decays, with average energy of 29 keV. The treatment of prostate cancer with permanent implantation of iodine-125 seeds has grown dramatically in the world in recent years. Most patients can return to normal life within three days with little or no pain. (author)

  14. Study and methodologies for fixing epoxy resin in radioactive sources used for brachytherapy

    International Nuclear Information System (INIS)

    Rodrigues, Bruna T.; Rostelato, Maria E.C.M.; Souza, Carla D.; Tozetti, Cíntia A.; Zeituni, Carlos A.; Nogueira, Beatriz R.; Silva, José T.; Júnior, Dib K.; Fernandes, Vagner; Souza, Raquel V.; Abreu, Rodrigo T.

    2017-01-01

    The World Health Organization (WHO) estimates that the number of new cancer cases worldwide will reach 15 million by 2020. The disease is already the second leading cause of death worldwide, being behind only cardiovascular disease. It is unquestionable that it is a public health problem, especially among developing countries. Prostate cancer is the most common among men, approximately 28.6%. The choice of type of treatment for prostate cancer should consider several factors such as: tumor size and extent, apparent aggressiveness (pathological characteristics), age, health. Among the methods applied, brachytherapy has been used in the initial and intermediate stages of the disease. Brachytherapy is a safe and effective treatment for localized prostate cancer. Brachytherapy is a form of radiotherapy in which radioactive seeds are placed in contact with or within the organ being treated. This technique allows a large dose of radiation to be released only on the target tumor that protects healthy surrounding tissues. Sources may have different shapes and sizes, but the one used for prostate cancer is usually 4.5 mm in length and 0.8 mm in diameter. About 80 to 120 seeds can be used per patient. Iodine-125 is the radioisotope most used in brachytherapy of the prostate, it emits 35,49keV X-rays in 100% of the decays, with average energy of 29 keV. The treatment of prostate cancer with permanent implantation of iodine-125 seeds has grown dramatically in the world in recent years. Most patients can return to normal life within three days with little or no pain. (author)

  15. [Technique of intraoperative planning in prostatic brachytherapy with permanent implants of 125I or 103Pd].

    Science.gov (United States)

    Prada Gómez, Pedro José; Juan Rijo, Germán; Hevia Suarez, Miguel; Abascal García, José María; Abascal García, Ramón

    2002-12-01

    Prostatic brachytherapy with permanent 125I or 123Pd seeds implantation is a therapeutic option for organ-confined prostate cancer. We analyze the technique based on previous planning, our current intraoperative planning procedure and the reasons that moved us to introduce this change. Changes in prostate volume and spatial localization observed between previous planning and intraoperative images, and possible difficulties for seed implantation due to pubic arch interference are some of the reasons that induce us to change technique. Before the operation, we calculate the prostatic volume by transrectal ultrasound; with this information we determine the total implant activity following Wu's nomogram, and per-seed activity; therefore, it is an individual process for each patient. We perform a peripheral implant, placing 75-80% of the seeds within the peripheral prostatic zone, generally through 12-15 needles, the rest of the seeds are placed in the central prostatic zone using a maximum of 3-4 needles in high volume prostates. The day of intervention, after positioning and catheter insertion, volumetry is re-checked. Ultrasound images (from base to apex every 5 mm) are transferred to the planner were a suitable seed distribution is determined. Implantation is then performed placing all needles unloaded, and then intraoperative post-planning to allow us to check implant precision is performed after cistoscopically check that there is no urethral or bladder penetration by any needle. We finish with the insertion of seeds into the prostate. Total time for the procedure is around 90 minutes. Intraoperative planning is an additional step for the treatment of prostate cancer with permanent seeds brachytherapy, which avoids the disadvantages of previous planning and improves tumor inclusion in the ideal irradiation dose area, which will translate into better local disease control.

  16. Post-operative treatment of malignant salivary gland tumours of the palate with iodine-125 brachytherapy

    International Nuclear Information System (INIS)

    Stannard, Clare E.; Hering, Egbert; Hough, Jan; Knowles, Ruth; Munro, Roger; Hille, Jos

    2004-01-01

    Background and purpose: Malignant minor salivary gland tumours are usually small and clinically indistinguishable from benign lesions. Surgery is the treatment of choice with post-operative radiotherapy for involved margins or unfavourable histology. We assessed the results of a series of such patients treated with iodine-125 brachytherapy in the form of a temporary applicator or implant. Patients and methods: There were nine patients with T1/T2 tumours of the hard and/or soft palate that had been excised. All had close or involved margins. Six were treated with a dental applicator alone, two with an applicator and additional I-125 seeds in tubes and one with an implant alone. The applicator consists of two layers of plastic made from a dental impression enclosing a predetermined number of I-125 seeds, 9-39, glued to one surface and a layer of ash metal to protect the tongue. It was inserted 1-3 months post-operatively and delivered 35-62 Gy, median 56 Gy, at 5-7 mm depth over 58-156 h, median 120 h, at 0.26-0.67 Gy/h, median 0.45 Gy/h. Results: The patients have been followed up for 32-158 months, median 50 months, and there were no recurrences. The applicator was well tolerated. A confluent mucositis developed which lasted 3-4 weeks. One patient developed a mucosal ulcer which healed spontaneously. Conclusions: Brachytherapy is an effective way of delivering post-operative radiotherapy to the hard and soft palate in patients with malignant salivary gland tumours that have been incompletely excised or have unfavourable histology. Local control is excellent, treatment time is short and morbidity is minimal

  17. Efficacy and safety of iodine-125 radioactive seeds brachytherapy for advanced non-small cell lung cancer-A meta-analysis.

    Science.gov (United States)

    Zhang, Wenchao; Li, Jiawei; Li, Ran; Zhang, Ying; Han, Mingyong; Ma, Wei

    This meta-analysis was conducted to investigate the efficacy and safety of 125 I brachytherapy for locally advanced non-small cell lung cancer (NSCLC). Trials comparing 125 I brachytherapy with chemotherapy in NSCLC were identified. Meta-analysis was performed to obtain pooled risk ratios for an overall response rate (ORR), disease control rate (DCR) and complications, and pooled hazard ratio for overall survival (OS). Fifteen studies including 1188 cases were included. The pooled result indicated that there were significant differences in ORR, DCR, and OS between 125 I brachytherapy combined with chemotherapy and chemotherapy alone, but no statistic differences in gastrointestinal symptoms, leukopenia, myelosuppression, and hemoglobin reduction. Patients treated with 125 I brachytherapy combined with chemotherapy have a higher relative risk of pneumothorax, bloody sputum, and pneumorrhagia compared with chemotherapy alone. Seeds migration only occurred in the group treated with 125 I brachytherapy. There were significant differences in ORR, DCR, and myelosuppression between 125 I brachytherapy alone and chemotherapy. 125 I brachytherapy combined with chemotherapy can significantly enhance the clinical efficacy and improve the OS of patients with advanced NSCLC without increasing the incidence of complications of chemotherapy. 125 I brachytherapy alone can significantly enhance the clinical efficacy and reduce the incidence of myelosuppression compared with chemotherapy. However, 125 I brachytherapy may cause lung injury. Large sample and higher-quality randomized controlled trials are needed to confirm the pooled results of complications. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  18. Patterns of failure after iodine-125 seed implantation for prostate cancer

    International Nuclear Information System (INIS)

    Lamb, David S.; Greig, Lynne; Russell, Grant L.; Nacey, John N.; Broome, Kim; Studd, Rod; Delahunt, Brett; Iupati, Douglas; Jain, Mohua; Rooney, Colin; Murray, Judy; Lamb, Peter J.; Bethwaite, Peter B.

    2014-01-01

    Purpose: To determine the site of relapse when biochemical failure (BF) occurs after iodine-125 seed implantation for prostate cancer. Materials and methods: From 2001–2009, 500 men underwent implantation in Wellington, New Zealand. Men who sustained BF were placed on relapse guidelines that delayed restaging and intervention until the prostate-specific antigen (PSA) was ⩾20 ng/mL. Results: Most implants (86%) had a prostate D90 of ⩾90%, and multivariate analysis showed that this parameter was not a variable that affected the risk of BF. Of 21 BFs that occurred, the site of failure was discovered to be local in one case and distant in nine cases. Restaging failed to identify the site of relapse in two cases. In nine cases the trigger for restaging had not been reached. Conclusions: If post-implant dosimetry is generally within the optimal range, distant rather than local failure appears to be the main cause of BF. Hormone treatment is therefore the most commonly indicated secondary treatment intervention (STI). Delaying the start of STI prevents the unnecessary treatment of men who undergo PSA ‘bounce’ and have PSA dynamics initially mimicking those of BF

  19. Methodology of quality control for brachytherapy {sup 125}I seeds

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Zeituni, Carlos A.; Manzoli, Jose E.; Rostelato, Maria Elisa C.M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: esmoura@ipen.br

    2007-07-01

    This paper presents the methodology of quality control of {sup 125}I seeds used for brachytherapy. The {sup 125}I seeds are millimeter titanium capsules widely used in permanent implants of prostate cancer, allowing a high dose within the tumour and a low dose on the surrounding tissues, with very low harm to the other tissues. Besides, with this procedure, the patients have a low impotence rate and a small incidence of urinary incontinence. To meet the medical standards, an efficient quality control is necessary, showing values with the minimum uncertainness possible, concerning the seeds dimensions and their respective activities. The medical needles are used to insert the seeds inside the prostate. The needles used in brachytherapy have an internal diameter of 1.0 mm, so it is necessary {sup 125}I seeds with an external maximum diameter of 0.85 mm. For the seeds and the spacer positioning on the planning sheet, the seeds must have a length between 4.5 and 5.0 mm. The activities must not vary more than 5% in each batch of {sup 125}I seeds. For this methodology, we used two ionization chamber detectors and one caliper. In this paper, the methodology using one control batch with 75 seeds manufactured by GE Health care Ltd is presented. (author)

  20. Influence of modifications in the positioning of phantoms in the Monte Carlo computational simulation of the prostate brachytherapy

    International Nuclear Information System (INIS)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson; Costa, Kleber Souza Silva; Lima, Fernando Roberto de Andrade

    2011-01-01

    Radiotherapy simulation procedures using Monte Carlo methods have shown to be increasingly important to the improvement of cancer fighting strategies. Within this context, brachytherapy is one of the most used methods to ensure better life quality when compared to other therapeutic modalities. These procedures are planned with the use of sectional exams with the patient in lying position. However, it is known that alteration of body posture after the procedure has an influence in the localization of many organs. This study had the aim to identify and to measure the influence of such alterations in MC brachytherapy simulations. In order to do so, prostate brachytherapy with the use of Iodine-125 radionuclide was chosen as model. Simulations were carried out with 108 events using EGSnrc code associated to MASH phantom in orthostatic and supine positions. Significant alterations were found, especially regarding bladder, small intestine and testicles. (author)

  1. Iodine 125 prostate brachytherapy: prognostic factors for long-term urinary, digestive and sexual toxicities;Curietherapie de prostate par iode 125: facteurs pronostiques de longue duree de toxicite urinaire, digestive et sexuelle

    Energy Technology Data Exchange (ETDEWEB)

    Doyen, J.; Mohammed Ali, A.; Ginot, A.; Ferre, M.; Castelli, J.; Hannoun-Levi, J.M. [Centre Antoine-Lacassagne, Dept. de Radiotherapie Oncologique, 06 - Nice (France); Chamorey, E. [Centre Antoine-Lacassagne, Unite de Statistiques Medicales, 06 - Nice (France); Mohammed Ali, A. [Faculte de Medecine, SOHAG (Egypt); Quintens, H.; Amiel, J. [CHU Pasteur, Service d' Urologie, 06 - Nice (France)

    2009-12-15

    Purpose For patients with good urinary function and presenting with a low risk prostate cancer, prostate brachytherapy using iodine implants represents one of the techniques of reference. This retrospective analysis investigates urinary (U), digestive (D) and sexual (S) toxicities and their prognostic factors of duration. Material and methods From August 2000 to November 2007, 176 patients presenting with prostate adenocarcinoma underwent interstitial brachytherapy. Urinary, digestive and sexual toxicities were classified according to Common toxicities criteria for adverse events, version 3.0 (C.T.C.A.E. V 3.0). For each toxicity (U, D, S), the number of complications U (dysuria, nicturia), D (proctitis, diarrhea) and S (sexual dysfunction, loss of libido) was listed and analyzed according to criteria related to the patient, implant, dosimetric data and characteristics of the toxicity. Prognostic factors identified in univariate analysis (U.V.A.) (Log Rank) were further analyzed in multivariate analysis (M.V.A.) (Cox model). Results With a median follow-up of 26 months (1-87), 147 patients (83.5 %) presented urinary toxicities. Among them, 29.5 % (86 patients) and 2.4 % (seven patients) presented grade 2 and 3 U toxicity respectively. In U.V.A., urinary grade toxicity greater than or equal to 2 (p = 0.037), the presence of initial U symptoms (p = 0.027) and more than two urinary toxicities (p 0.00032) were recognized as prognostic factors. The number of U toxicities was the only prognostic factor in M.V.A. (p = 0.04). D toxicity accounted for 40.6 % (71 patients). Among them, 3 % (six patients) were grade 2. None were grade 3. Two factors were identified as prognostic factors either in U.V.A. and M.V.A.: the number of D toxicities greater than or equal to 2 (univariate analysis: p = 0,00129, multivariate analysis: p = 0,002) and age less than or equal to 65 years (univariate analysis: p = 0,004, multivariate analysis: p 0,007). Eighty-three patients (47

  2. A comparison of complications between ultrasound-guided prostate brachytherapy and open prostate brachytherapy

    International Nuclear Information System (INIS)

    Benoit, Ronald M.; Naslund, Michael J.; Cohen, Jeffrey K.

    2000-01-01

    Purpose: Prostate brachytherapy has reemerged during the 1990s as a treatment for clinically localized prostate cancer. The renewed popularity of prostate brachytherapy is largely due to the use of transrectal ultrasound of the prostate, which allows for more accurate isotope placement within the prostate when compared to the open approach. The present study investigates whether this improved cancer control is at the expense of increased morbidity by comparing the morbidity after transrectal ultrasound-guided prostate brachytherapy to the morbidity after prostate brachytherapy performed via an open approach. Methods and Materials: All men in the Medicare population who underwent prostate brachytherapy in the year 1991 were identified. These men were further stratified into those men who underwent prostate brachytherapy via an open approach and the men who underwent prostate brachytherapy with ultrasound guidance. All subsequent inpatient, outpatient, and physician (Part B) Medicare claims for these men from the years 1991-1993 were then analyzed to determine outcomes. Results: In the year 1991, 2124 men in the Medicare population underwent prostate brachytherapy. An open approach was used in 715 men (33.7%), and ultrasound guidance was used in 1409 men (66.3%). Mean age for both cohorts was 73.7 years with a range of 50.7-92.8 years for the ultrasound group and 60.6-92.1 years for the open group. A surgical procedure for the relief of bladder outlet obstruction was performed in 122 men (8.6%) in the ultrasound group and in 54 men (7.6%) in the open group. An artificial urinary sphincter was placed in 2 men (0.14%) in the ultrasound group and in 2 men (0.28%) in the open group. A penile prosthesis was implanted in 10 men (0.71%) in the ultrasound group and in 4 men (0.56%) in the open group. A diagnosis code for urinary incontinence was carried by 95 men (6.7%) in the ultrasound group and by 45 men (6.3%) in the open group. A diagnosis code for erectile dysfunction

  3. Prospective evaluation of quality of life after permanent prostate brachytherapy with I-125: Importance of baseline symptoms and of prostate-V150

    International Nuclear Information System (INIS)

    Vordermark, Dirk; Noe, Michael; Markert, Klaus; Wulf, Joern; Mueller, Gerd; Bratengeier, Klaus; Beckmann, Gabriele; Baier, Fabian; Guckenberger, Matthias; Schiefelbein, Frank; Schoen, Georg; Flentje, Michael; Baier, Kurt

    2009-01-01

    Background and purpose: Detailed knowledge of quality of life (QoL) after permanent I-125 brachytherapy may aid in counselling patients with early-stage prostate cancer. Materials and methods: Seventy-four consecutive patients with low-risk prostate cancer were asked to complete the EORTC QLQ-C30 questionnaire with the prostate-specific PR25 module before implant, four weeks and one year after implant (response rates 97%, 88% and 89%, respectively). Implant characteristics were correlated with QoL scores. Results: Global QoL was stable from pre-treatment to one year after implant and similar to age-adjusted scores of healthy controls. Significant changes versus baseline in QLQ-C30 domains were worsened social function at four weeks, increased constipation at four weeks and at one year and improved emotional function at one year. PR25 urinary symptoms were significantly increased at four weeks and, despite some improvement, at one year; bowel symptoms were slightly increased. Both types of symptoms were most strongly related with pre-treatment symptom scores. Prostate-V150 was the only implant parameter significantly associated with both urinary and bowel symptoms at four weeks and one year. Conclusions: Limiting the high-dose subvolume in the prostate may be beneficial to reduce urinary and bowel symptoms but the major determinant of symptoms after I-125 implant is the baseline symptom level.

  4. Factors influencing upon the incidence of seed migration in I-125 seed transperineal prostate implantation

    International Nuclear Information System (INIS)

    Itami, Jun; Onishi, Kayoko; Kanemura, Mikio

    2005-01-01

    Transperineal I-125 seed brachytherapy for prostate cancer is rapidly expanding in Japan. Seed migrations to lung and abdomen are well known complication in the seed brachytherapy. The rate of incidence and the predisposing factors were studied. From April 2004 through January 2005, 36 patients underwent transperineal I-125 seed brachytherapy for prostate cancer. In all patients loose I-125 seeds were inserted with Mick applicator according to modified peripheral loading pattern. One day, 1 week, and 1 month after the procedure, posteroanterior and lateral chest X-rays and abdominal X-ray were performed. Abdominal and chest seed migrations were seen in 11 (30.6%) and 14 (38.9%) patients, respectively. In total, 20 patients (55.6%) showed seed migrations. Forty-two I-125 seeds migrated out of 2,508 implanted seeds. Most of the migrations were seen until 1 month after the procedure. The preplanned number of the extraprostatic seeds had a statistically significant influence upon the incidence of seed migration. Seed migration is not a rare phenomenon in transperineal I-125 seed brachytherapy for prostate cancer. To confirm seed migration, X-ray examinations 1 month after the procedure are suited. At the preplanning, the number of extraprostatic seeds should be limited to minimal to decrease the incidence of seed migration. In future, the introduction of linked I-125 seeds is preferred. (author)

  5. Incidence of seed migration to the chest, abdomen, and pelvis after transperineal interstitial prostate brachytherapy with loose 125I seeds

    International Nuclear Information System (INIS)

    Sugawara, Akitomo; Shigematsu, Naoyuki; Nakashima, Jun; Kunieda, Etsuo; Nagata, Hirohiko; Mizuno, Ryuichi; Seki, Satoshi; Shiraishi, Yutaka; Kouta, Ryuichi; Oya, Mototsugu

    2011-01-01

    The aim was to determine the incidence of seed migration not only to the chest, but also to the abdomen and pelvis after transperineal interstitial prostate brachytherapy with loose 125 I seeds. We reviewed the records of 267 patients who underwent prostate brachytherapy with loose 125 I seeds. After seed implantation, orthogonal chest radiographs, an abdominal radiograph, and a pelvic radiograph were undertaken routinely to document the occurrence and sites of seed migration. The incidence of seed migration to the chest, abdomen, and pelvis was calculated. All patients who had seed migration to the abdomen and pelvis subsequently underwent a computed tomography scan to identify the exact location of the migrated seeds. Postimplant dosimetric analysis was undertaken, and dosimetric results were compared between patients with and without seed migration. A total of 19,236 seeds were implanted in 267 patients. Overall, 91 of 19,236 (0.47%) seeds migrated in 66 of 267 (24.7%) patients. Sixty-nine (0.36%) seeds migrated to the chest in 54 (20.2%) patients. Seven (0.036%) seeds migrated to the abdomen in six (2.2%) patients. Fifteen (0.078%) seeds migrated to the pelvis in 15 (5.6%) patients. Seed migration occurred predominantly within two weeks after seed implantation. None of the 66 patients had symptoms related to the migrated seeds. Postimplant prostate D90 was not significantly different between patients with and without seed migration. We showed the incidence of seed migration to the chest, abdomen and pelvis. Seed migration did not have a significant effect on postimplant prostate D90

  6. Development of computational models for the simulation of isodose curves on dosimetry films generated by iodine-125 brachytherapy seeds

    International Nuclear Information System (INIS)

    Santos, Adriano M.; Meira-Belo, Luiz C.; Reis, Sergio C.; Grynberg, Suely E.

    2011-01-01

    The interstitial brachytherapy is one modality of radiotherapy in which radioactive sources are placed directly in the region to be treated or close to it. The seeds that are used in the treatment of prostate cancer are generally cylindrical radioactive sources, consisting of a ceramic or metal matrix, which acts as the carrier of the radionuclide and as the X-ray marker, encapsulated in a sealed titanium tube. This study aimed to develop a computational model to reproduce the film-seed geometry, in order to obtain the spatial regions of the isodose curves produced by the seed when it is put over the film surface. The seed modeled in this work was the OncoSeed 6711, a sealed source of iodine-125, which its isodose curves were obtained experimentally in previous work with the use of dosimetric films. For the films modeling, compositions and densities of the two types of dosimetric films were used: Agfa Personal Monitoring photographic film 2/10, manufactured by Agfa-Geavaert; and the model EBT radiochromic film, by International Specialty Products. The film-seed models were coupled to the Monte Carlo code MCNP5. The results obtained by simulations showed to be in good agreement with experimental results performed in a previous work. This indicates that the computational model can be used in future studies for other seeds models. (author)

  7. Development of computational models for the simulation of isodose curves on dosimetry films generated by iodine-125 brachytherapy seeds

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Adriano M.; Meira-Belo, Luiz C.; Reis, Sergio C.; Grynberg, Suely E., E-mail: amsantos@cdtn.b [Center for Development of Nuclear Technology (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The interstitial brachytherapy is one modality of radiotherapy in which radioactive sources are placed directly in the region to be treated or close to it. The seeds that are used in the treatment of prostate cancer are generally cylindrical radioactive sources, consisting of a ceramic or metal matrix, which acts as the carrier of the radionuclide and as the X-ray marker, encapsulated in a sealed titanium tube. This study aimed to develop a computational model to reproduce the film-seed geometry, in order to obtain the spatial regions of the isodose curves produced by the seed when it is put over the film surface. The seed modeled in this work was the OncoSeed 6711, a sealed source of iodine-125, which its isodose curves were obtained experimentally in previous work with the use of dosimetric films. For the films modeling, compositions and densities of the two types of dosimetric films were used: Agfa Personal Monitoring photographic film 2/10, manufactured by Agfa-Geavaert; and the model EBT radiochromic film, by International Specialty Products. The film-seed models were coupled to the Monte Carlo code MCNP5. The results obtained by simulations showed to be in good agreement with experimental results performed in a previous work. This indicates that the computational model can be used in future studies for other seeds models. (author)

  8. Prostate brachytherapy - discharge

    Science.gov (United States)

    Implant therapy - prostate cancer - discharge; Radioactive seed placement - discharge ... You had a procedure called brachytherapy to treat prostate cancer. Your treatment lasted 30 minutes or more, ...

  9. Dose optimization in simulated permanent interstitial implant of prostate brachytherapy

    International Nuclear Information System (INIS)

    Faria, Fernando Pereira de

    2006-01-01

    Any treatment of cancer that uses some modality of radiotherapy is planned before being executed. In general the goal in radiotherapy is to irradiate the target to be treated minimizing the incidence of radiation in healthy surrounding tissues. The planning differ among themselves according to the modality of radiotherapy, the type of cancer and where it is located. This work approaches the problem of dose optimization for the planning of prostate cancer treatment through the modality of low dose-rate brachytherapy with Iodine 125 or Palladium 103 seeds. An algorithm for dose calculation and optimization was constructed to find the seeds configuration that better fits the relevant clinical criteria such as as the tolerated dose by the urethra and rectum and the desired dose for prostate. The algorithm automatically finds this configuration from the prostate geometry established in two or three dimensions by using images of ultrasound, magnetic resonance or tomography and from the establishment of minimum restrictions to the positions of the seeds in the prostate and needles in a template. Six patterns of seeds distribution based on clinical criteria were suggested and tested in this work. Each one of these patterns generated a space of possible seeds configurations for the prostate tested by the dose calculation and optimization algorithm. The configurations that satisfied the clinical criteria were submitted to a test according to an optimization function suggested in this work. The configuration that produced maximum value for this function was considered the optimized one. (author)

  10. Interstitial prostate brachytherapy. LDR-PDR-HDR

    International Nuclear Information System (INIS)

    Kovacs, Gyoergy; Hoskin, Peter

    2013-01-01

    The first comprehensive overview of interstitial brachytherapy for the management of local or locally advanced prostate cancer. Written by an interdisciplinary team who have been responsible for the successful GEC-ESTRO/EAU Teaching Course. Discusses in detail patient selection, the results of different methods, the role of imaging, and medical physics issues. Prostate brachytherapy has been the subject of heated debate among surgeons and the proponents of the various brachytherapy methods. This very first interdisciplinary book on the subject provides a comprehensive overview of innovations in low dose rate (LDR), high dose rate (HDR), and pulsed dose rate (PDR) interstitial brachytherapy for the management of local or locally advanced prostate cancer. In addition to detailed chapters on patient selection and the use of imaging in diagnostics, treatment guidance, and implantation control, background chapters are included on related medical physics issues such as treatment planning and quality assurance. The results obtained with the different treatment options and the difficult task of salvage treatment are fully discussed. All chapters have been written by internationally recognized experts in their fields who for more than a decade have formed the teaching staff responsible for the successful GEC-ESTRO/EAU Prostate Brachytherapy Teaching Course. This book will be invaluable in informing residents and others of the scientific background and potential of modern prostate brachytherapy. It will also prove a useful source of up-to-date information for those who specialize in prostate brachytherapy or intend to start an interstitial brachytherapy service.

  11. Development of a patient-reported questionnaire for collecting toxicity data following prostate brachytherapy

    International Nuclear Information System (INIS)

    Farnell, Damian J.J.; Mandall, Paula; Anandadas, Carmel; Routledge, Jaqueline; Burns, Meriel P.; Logue, John P.; Wylie, James P.; Swindell, Ric; Livsey, Jac; West, Catharine M.L.; Davidson, Susan E.

    2010-01-01

    Purpose: To improve a questionnaire used to collect patient-reported outcomes from patients with early stage prostate cancer treated with brachytherapy. A secondary aim was to adapt the Late Effects of Normal Tissue (LENT) subjective toxicity questionnaire for use to collect Common Terminology Criteria for Adverse Events (CTCAE) data, the current preferred platform for assessing radiation toxicity. Materials and methods: Three hundred and seventy-seven patients were treated with permanent iodine-125 seed implant brachytherapy for early prostate cancer. Toxicity data were collected before and at nine time points post-treatment (0-36 months). Compliance rates for patients completing individual items and item-subsection correlation coefficients were calculated. A factor analysis was carried out to analyse responses to the questionnaire and identify less informative questions, which could be removed. Cronbach's α coefficient was used to measure reliability. Results: Two thousand one hundred and eighty-eight questionnaires were analysed. There was poor compliance for questions specifically relating to operations and bowel medication. We found that the division of the questionnaire into subsections based on anatomical site was reasonable and that certain items could be safely removed. The high mean value for Cronbach's α across all questionnaires (0.752; 95% CI: 0.726-0.779) indicated that the questionnaire was reliable. Fifteen of the 44 questions were removed from the original questionnaires. Questions on urinary incontinence severity, management of urinary and bowel incontinence, effects of reduced flow of urine and the effects of symptoms on activity of daily living and change in sexual function were required to adapt the LENT subjective questionnaire for use to collect CTCAE data. Conclusions: A questionnaire, validated over 6 years to collect LENT subjective data were adapted and is a reliable approach for collecting CTCAE data after prostate brachytherapy.

  12. Effect of edema, relative biological effectiveness, and dose heterogeneity on prostate brachytherapy

    International Nuclear Information System (INIS)

    Wang, Jian Z.; Mayr, Nina A.; Nag, Subir; Montebello, Joseph; Gupta, Nilendu; Samsami, Nina; Kanellitsas, Christos

    2006-01-01

    Many factors influence response in low-dose-rate (LDR) brachytherapy of prostate cancer. Among them, edema, relative biological effectiveness (RBE), and dose heterogeneity have not been fully modeled previously. In this work, the generalized linear-quadratic (LQ) model, extended to account for the effects of edema, RBE, and dose heterogeneity, was used to assess these factors and their combination effect. Published clinical data have shown that prostate edema after seed implant has a magnitude (ratio of post- to preimplant volume) of 1.3-2.0 and resolves exponentially with a half-life of 4-25 days over the duration of the implant dose delivery. Based on these parameters and a representative dose-volume histogram (DVH), we investigated the influence of edema on the implant dose distribution. The LQ parameters (α=0.15 Gy -1 and α/β=3.1 Gy) determined in earlier studies were used to calculate the equivalent uniform dose in 2 Gy fractions (EUD 2 ) with respect to three effects: edema, RBE, and dose heterogeneity for 125 I and 103 Pd implants. The EUD 2 analysis shows a negative effect of edema and dose heterogeneity on tumor cell killing because the prostate edema degrades the dose coverage to tumor target. For the representative DVH, the V 100 (volume covered by 100% of prescription dose) decreases from 93% to 91% and 86%, and the D 90 (dose covering 90% of target volume) decrease from 107% to 102% and 94% of prescription dose for 125 I and 103 Pd implants, respectively. Conversely, the RBE effect of LDR brachytherapy [versus external-beam radiotherapy (EBRT) and high-dose-rate (HDR) brachytherapy] enhances dose effect on tumor cell kill. In order to balance the negative effects of edema and dose heterogeneity, the RBE of prostate brachytherapy was determined to be approximately 1.2-1.4 for 125 I and 1.3-1.6 for 103 Pd implants. These RBE values are consistent with the RBE data published in the literature. These results may explain why in earlier modeling studies

  13. The Effect of Dose and Quality Assurance in Early Prostate Cancer Treated with Low Dose Rate Brachytherapy as Monotherapy.

    Science.gov (United States)

    Henry, A M; Rodda, S L; Mason, M; Musunuru, H; Al-Qaisieh, B; Bownes, P; Smith, J; Franks, K; Carey, B; Bottomley, D

    2015-07-01

    To examine the relationship between post-implant computed tomography dosimetry and long-term prostate-specific antigen relapse-free survival in patients treated with iodine 125 (I-125) low dose rate prostate brachytherapy as monotherapy and, second, to audit recent practice against Royal College of Radiologists' (RCR) guidelines after the re-introduction of post-implant dosimetry for all patients in our centre. Between March 1995 and September 2007, 2157 consecutive patients with localised prostate cancer underwent I-125 permanent prostate brachytherapy as monotherapy in a single UK centre. All patients were transrectal ultrasound planned delivering a 145 Gy (TG 43) minimum peripheral dose. None received supplemental external beam radiotherapy. Post-implant computed tomography-based dosimetry was undertaken between 4 and 6 weeks after treatment and was available for 711 (33%). Outcomes were analysed in terms of the relationship of D90 to prostate-specific antigen relapse-free survival (nadir 2+ definition) and all patients had a minimum follow-up of 5 years. For contemporary patients from 2011, quality metrics from post-implant computed tomography as defined by RCR guidelines are presented. A mean D90 of 138.7 Gy (standard deviation 24.7) was achieved for the historic cohort. Biochemical control at 10 years was 76% in patients with D90 > 140 Gy and 68% in those with D90 standard deviation) D90 has increased from 154 (15.3) Gy in 2011 to 164 (13.5) Gy in 2013. Similarly, an increase in the mean (standard deviation) V100 from 92 (4.4) to 95 (3.2) % is noted over time. No difference between clinicians was noted. D90 values of less than 140 Gy continue to be predictive of increased risk of recurrence of prostate cancer across risk groups with longer follow-up. Quality assurance can be used to ensure improved and consistent implant quality in a team with multiple clinicians. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights

  14. Correlations of post-implant regional dosimetric parameters at 24 hours and one month, with clinical results of low-dose-rate brachytherapy for localized prostate cancer

    Directory of Open Access Journals (Sweden)

    Eiichiro Okazaki

    2017-12-01

    Full Text Available Purpose : To evaluate the correlations of post-implant regional dosimetrics at 24 hours (24 h and 1 month after implant procedures, with clinical outcomes of low-dose-rate (LDR brachytherapy for localized prostate cancer. Material and methods : Between January 2008 and December 2014, 130 consecutive patients treated for localized prostate cancer, receiving definitive iodine-125 ( 125 I brachytherapy treatment were retrospectively analyzed. All patients underwent post-implant CT imaging for dosimetric analysis at 24 h and 1 month after implantation procedure. Prostate contours were divided into quadrants: anterior-superior (ASQ, posterior-superior (PSQ, anterior-inferior (AIQ, and posterior-inferior (PIQ. Predictive factors and cut-off values of biochemical failure-free survival (BFFS and toxicities of LDR brachytherapy were analyzed. Results : The median follow-up time was 69.5 months. Seven patients (5.4% had biochemical failure. The 3-year and 5-year BFFS rates were 96.7% and 93.1%, respectively. On multivariate analysis, prostate-specific antigen and Gleason score were significant prognostic factors for biochemical failure. D 90 (the minimal dose received by 90% of the volume of PSQ and PIQ at 24 h, and D 90 of PSQ at 1 month were also significant factors. The cut-off values of PSQ D 90 were 145 Gy at 24 h and 160 Gy at 1 month. D 90 of the whole prostate was not significant at 24 h and at 1 month. D 90 of PSQ at 1 month was a significant factor for rectal hemorrhage. Conclusions : Post-implant D 90 of PSQ is significantly associated with BFFS for localized prostate cancer not only at 1 month, but also at 24 hours. D 90 of PSQ at 1 month is also a significant factor for rectal hemorrhage.

  15. Urethral toxicity after LDR brachytherapy: experience in Japan.

    Science.gov (United States)

    Tanaka, Nobumichi; Asakawa, Isao; Hasegawa, Masatoshi; Fujimoto, Kiyohide

    2015-01-01

    Urinary toxicity is common after low-dose-rate (LDR) brachytherapy, and the resolution of urinary toxicity is a concern. In particular, urinary frequency is the most common adverse event among the urinary toxicities. We have previously reported that approximately 70% of patients experience urinary frequency during the first 6 months after seed implantation. Most urinary adverse events were classified as Grade 1, and Grade 2 or higher adverse events were rare. The incidence of urinary retention was approximately 2-4%. A high International Prostate Symptom Score before seed implantation was an independent predictor of acute urinary toxicity of Grade 2 or higher. Several previous reports from the United States also supported this trend. In Japan, LDR brachytherapy was legally approved in 2003. A nationwide prospective cohort study entitled Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation was initiated in July 2005. It is an important issue to limit urinary toxicities in patients who undergo LDR brachytherapy. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  16. Radiation safety parameters following prostate brachytherapy

    International Nuclear Information System (INIS)

    Smathers, Sesalie; Wallner, Kent; Korssjoen, Tammy; Bergsagel, Carl; Hudson, Rick H.; Sutlief, Steven; Blasko, John

    1999-01-01

    Purpose: To determine the degree and variability of radiation exposure to the general public from patients after I-125 or Pd-103 prostate brachytherapy. Methods and Materials: Radiation exposure measurements were made from 38 consecutive, unselected patients with stage T1 or T2 prostatic carcinoma who had trans perineal I-125 or Pd-103 implants at the University of Washington in 1998. Results: The exposure rate at the anterior skin surface following a I-125 implant ranged from 2.2 to 8.9 mrem/hour (average: 5.0). The exposure rate at the anterior skin surface from a Pd-103 implant ranged from 0.5 to 4.9 mrem/hour (average: 1.7). Based on the current Nuclear Regulatory Commission (NRC) regulations the time required to reach the annual limit at the anterior skin surface would be 20 hours for I-125 and 59 hours for Pd-103. For exposure at the lateral skin surface, the times would exceed 500 hours for either isotope. Conclusions: This data suggest that patients need not be concerned about being a radiation risk to the general public following their procedure

  17. The dosimetry of prostate brachytherapy-induced urethral strictures

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Tollenaar, Bryan G.; Galbreath, Robert W.; Lief, Jonathan H.

    2002-01-01

    Purpose: There is a paucity of data regarding the incidence of urethral strictures after prostate brachytherapy. In this study, we evaluate multiple clinical, treatment, and dosimetric parameters to identify factors associated with the development of brachytherapy-induced urethral strictures. Methods and Materials: 425 patients underwent transperineal ultrasound-guided prostate brachytherapy using either 103 Pd or 125 I for clinical T1b/T3a NxM0 (1997, American Joint Committee on Cancer) adenocarcinoma of the prostate gland from April 1995 to October 1999. No patient was lost to follow-up. 221 patients were implanted with 103 Pd and 204 patients with 125 I. The median patient age was 68 years (range 48-81 years). The median follow-up was 35.2 months (range 15-72 months). Follow-up was calculated from the day of implantation. Thirteen patients developed brachytherapy-induced strictures, and all strictures involved the membranous urethra. A control group of 35 patients was rigorously matched to the stricture patients in terms of treatment approach; i.e., choice of isotope, plus or minus radiation therapy, and plus or minus hormonal manipulation. Nine of the 13 stricture patients had detailed Day 0 urethral dosimetry available for review. The apex of the prostate gland and the membranous urethra were defined by CT evaluation. Urethral dosimetry was reported for the prostatic urethra, the apical slice of the prostate gland, and the membranous urethra which was defined as extending 20 mm in length. Results: The 5-year actuarial risk of a urethral stricture was 5.3%, with a median time to development of 26.6 months (range 7.8-44.1 months). Of multiple clinical and treatment parameters evaluated, only the duration of hormonal manipulation (>4 months, p=0.011) was predictive for the development of a urethral stricture. The radiation dose to the membranous urethra was significantly greater in patients with strictures than those without: 97.6%±20.8% vs. 81.0%±19.8% of

  18. Predictive factors for acute and late urinary toxicity after permanent interstitial brachytherapy in Japanese patients

    International Nuclear Information System (INIS)

    Tanimoto, Ryuta; Bekku, Kensuke; Katayama, Norihisa

    2013-01-01

    The objectives of this study were to describe the frequency of and to determine predictive factors associated with Radiation Therapy Oncology Group urinary toxicity in prostate brachytherapy patients. From January 2004 to April 2011, 466 consecutive Japanese patients underwent permanent iodine-125-seed brachytherapy (median follow up 48 months). International Prostate Symptom Score and Radiation Therapy Oncology Group toxicity data were prospectively collected. Prostate volume, International Prostate Symptom Score before and after brachytherapy, and postimplant analysis were examined for an association with urinary toxicity, defined as Radiation Therapy Oncology Group urinary toxicity of Grade 1 or higher. Logistic regression analysis was used to examine the factors associated with urinary toxicity. The rate of Radiation Therapy Oncology Group urinary toxicity grade 1 or higher at 1, 6, 12, 24, 36 and 48 months was 67%, 40%, 21%, 31%, 27% and 28%, respectively. Grade 2 or higher urinary toxicity was less than 1% at each time-point. International Prostate Symptom Score was highest at 3 months and returned to normal 12 months after brachytherapy. On multivariate analysis, patients with a larger prostate size, greater baseline International Prostate Symptom Score, higher prostate V100, higher prostate V150, higher prostate D90 and a greater number of seeds had more acute urinary toxicities at 1 month and 12 months after brachytherapy. On multivariate analysis, significant predictors for urinary toxicity at 1 month and 12 months were a greater baseline International Prostate Symptom Score and prostate V100. Most urinary symptoms are tolerated and resolved within 12 months after prostate brachytherapy. Acute and late urinary toxicity after brachytherapy is strongly related to the baseline International Prostate Symptom Score and prostate V100. (author)

  19. Iodine-125 brachytherapy as upfront and salvage treatment for brain metastases. A comparative analysis

    Energy Technology Data Exchange (ETDEWEB)

    Romagna, Alexander; Schwartz, Christoph; Tonn, Joerg-Christian; Kreth, Friedrich-Wilhelm [Ludwig-Maximilians-University, Department of Neurosurgery, Munich (Germany); Egensperger, Rupert [Ludwig-Maximilians-University, Center for Neuropathology and Prion Research, Munich (Germany); Watson, Juliana; Belka, Claus; Nachbichler, Silke Birgit [Ludwig-Maximilians-University, Department of Radiation-Oncology, Munich (Germany)

    2016-11-15

    Outcome and toxicity profiles of salvage stereotactic ablative radiation strategies for recurrent pre-irradiated brain metastases are poorly defined. This study compared risk-benefit profiles of upfront and salvage iodine-125 brachytherapy (SBT) for small brain metastases. As the applied SBT treatment algorithm required histologic proof of metastatic brain disease in all patients, we additionally aimed to elucidate the value of biopsy before SBT. Patients with small untreated (n = 20) or pre-irradiated (n =28) suspected metastases intended for upfront or salvage SBT, respectively, were consecutively included. Temporary iodine-125 implants were used (median reference dose: 50 Gy, median dose rate: 15 cGy/h). Cumulative biologically effective doses (BED) were calculated and used for risk assessment. Treatment toxicity was classified according to Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG/EORTC) criteria. Upfront SBT was initiated in 20 patients and salvage SBT in 23. In 5 patients, salvage SBT was withheld because of proven radiation-induced lesions. Treatment groups exhibited similar epidemiologic data except for tumor size (which was slightly smaller in the salvage group). One-year local/distant tumor control rates after upfront and salvage SBT were similar (94 %/65 % vs. 87 %/57 %, p = 0.45, respectively). Grade I/II toxicity was suffered by 2 patients after salvage SBT (cumulative BED: 192.1 Gy{sub 3} and 249.6 Gy{sub 3}). No toxicity-related risk factors were identified. SBT combines diagnostic yield with effective treatment in selected patients. The low toxicity rate in the salvage group points to protective radiobiologic characteristics of continuous low-dose rate irradiation. Upfront and salvage SBT are similarly effective and safe. Histologic reevaluation should be reconsidered after previous radiotherapy to avoid under- or overtreatment. (orig.) [German] Daten zu Risiko und Effizienz ablativer

  20. Sequential evaluation of prostate edema after permanent seed prostate brachytherapy using CT-MRI fusion

    International Nuclear Information System (INIS)

    Taussky, Daniel; Austen, Lyn; Toi, Ants; Yeung, Ivan; Williams, Theresa; Pearson, Shannon; McLean, Michael; Pond, Gregory; Crook, Juanita

    2005-01-01

    Purpose: To analyze the extent and time course of prostate edema and its effect on dosimetry after permanent seed prostate brachytherapy. Methods and Materials: Twenty patients scheduled for permanent seed 125 I prostate brachytherapy agreed to a prospective study on postimplant edema. Implants were preplanned using transrectal ultrasonography. Postimplant dosimetry was calculated using computed tomography-magnetic resonance imaging (CT-MRI) fusion on the day of the implant (Day 1) and Days 8 and 30. The prostate was contoured on MRI, and the seeds were located on CT. Factors investigated for an influence on edema were the number of seeds and needles, preimplant prostate volume, transitional zone index (transition zone volume divided by prostate volume), age, and prostate-specific antigen level. Prostate dosimetry was evaluated by the percentage of the prostate volume receiving 100% of the prescribed dose (V 100 ) and percentage of prescribed dose received by 90% of the prostate volume (D 90 ). Results: Prostate edema was maximal on Day 1, with the median prostate volume 31% greater than preimplant transrectal ultrasound volume (range, 0.93-1.72; p 100 on Day 1 was 93.6% (range, 86.0-98.2%) and was 96.3% (range, 85.7-99.5%) on Day 30 (p = 0.079). Patients with a Day 1 V 100 >93% were less affected by edema resolution, showing a median increase in V 100 of 0.67% on Day 30 compared with 2.77% for patients with a V 100 100 >93%)

  1. Erectile function after prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Galbreath, Robert W.; Anderson, Richard L.; Kurko, Brian S.; Lief, Jonathan H.; Allen, Zachariah A.

    2005-01-01

    Purpose: To evaluate erectile function after permanent prostate brachytherapy using a validated patient-administered questionnaire and to determine the effect of multiple clinical, treatment, and dosimetric parameters on penile erectile function. Methods and materials: A total of 226 patients with preimplant erectile function determined by the International Index of Erectile Function (IIEF) questionnaire underwent permanent prostate brachytherapy in two prospective randomized trials between February 2001 and January 2003 for clinical Stage T1c-T2c (2002 American Joint Committee on Cancer) prostate cancer. Of the 226 patients, 132 were potent before treatment and, of those, 128 (97%) completed and returned the IIEF questionnaire after brachytherapy. The median follow-up was 29.1 months. Potency was defined as an IIEF score of ≥13. The clinical, treatment, and dosimetric parameters evaluated included patient age; preimplant IIEF score; clinical T stage; pretreatment prostate-specific antigen level; Gleason score; elapsed time after implantation; preimplant nocturnal erections; body mass index; presence of hypertension or diabetes mellitus; tobacco consumption; the volume of the prostate gland receiving 100%, 150%, and 200% of the prescribed dose (V 100/150/200 ); the dose delivered to 90% of the prostate gland (D 90 ); androgen deprivation therapy; supplemental external beam radiotherapy (EBRT); isotope; prostate volume; planning volume; and radiation dose to the proximal penis. Results: The 3-year actuarial rate of potency preservation was 50.5%. For patients who maintained adequate posttreatment erectile function, the preimplant IIEF score was 29, and in patients with brachytherapy-related ED, the preimplant IIEF score was 25. The median time to the onset of ED was 5.4 months. After brachytherapy, the median IIEF score was 20 in potent patients and 3 in impotent patients. On univariate analysis, the preimplant IIEF score, patient age, presence of nocturnal

  2. Erectile function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Stipetich, Robin L.; Abel, Laurie J.; Lief, Jonathan H.

    2002-01-01

    Purpose: To determine the incidence of potency preservation after permanent prostate brachytherapy using a validated patient-administered questionnaire and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Methods and Materials: Four hundred twenty-five patients underwent permanent prostate brachytherapy from April 1995 to October 1999. Two hundred nine patients who were potent before brachytherapy and who at the time of the survey were not receiving hormonal therapy were mailed the specific erectile questions of the International Index of Erectile Function (IIEF) questionnaire with a self-addressed stamped envelope. The questionnaire consisted of 5 questions, with a maximal score of 25. Of the 209 patients, 181 (87%) completed and returned the questionnaire. The mean and median follow-up was 40.4±14.9 and 40.6 months, respectively (range 19-75). Preimplant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Postimplant potency was defined as an IIEF score ≥11. The clinical parameters evaluated for erectile function included patient age, preimplant potency, clinical T-stage, pretreatment prostate-specific antigen level, Gleason score, elapsed time after implantation, hypertension, diabetes mellitus, and tobacco consumption. Treatment parameters included radiation dose to the prostate gland, use of hormonal manipulation, use of supplemental external beam radiotherapy (EBRT), choice of isotope, prostate volume, and planning volume. The efficacy of sildenafil citrate in brachytherapy-induced erectile dysfunction (ED) was also evaluated. Results: Pretreatment erectile function scores of 2 and 1 were assigned to 125 and 56 patients, respectively. With a 6-year follow

  3. Five-year biochemical outcome following permanent interstitial brachytherapy for clinical T1-T3 prostate cancer

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Lief, Jonathan H.

    2001-01-01

    Purpose: To evaluate 5-year biochemical disease-free outcome for men with clinical T1b-T3a NxM0 1977 American Joint Committee on Cancer (1997 AJCC) adenocarcinoma of the prostate gland who underwent transperineal ultrasound-guided permanent prostate brachytherapy. Methods and Materials: Four hundred twenty-five patients underwent transperineal ultrasound-guided prostate brachytherapy using either 103 Pd or 125 I, for clinical T1b-T3a NxM0 (1997 AJCC) adenocarcinoma of the prostate gland, from April 1995 to October 1999. No patient underwent pathologic lymph-node staging. One hundred ninety patients were implanted with either 103 Pd or 125 I monotherapy; 235 patients received moderate-dose external beam radiation therapy (EBRT), followed by a prostate brachytherapy boost; 163 patients received neoadjuvant hormonal manipulation, in conjunction with either 103 Pd or 125 I monotherapy (77 patients) or in conjunction with moderate-dose EBRT and a prostate brachytherapy boost (86 patients). The median patient age was 68.0 years (range, 48.2-81.3 years). The median follow-up was 31 months (range, 11-69 months). Follow-up was calculated from the day of implantation. No patient was lost to follow-up. Biochemical disease-free survival was defined by the American Society of Therapeutic Radiation and Oncology (ASTRO) consensus definition. Results: For the entire cohort, the 5-year actuarial biochemical no evidence of disease (bNED) survival rate was 94%. For patients with low-, intermediate-, and high-risk disease, the 5-year biochemical disease-free rates were 97.1%, 97.5%, and 84.4%, respectively. For hormone-naive patients, 95.7%, 96.4%, and 79.9% of patients with low-, intermediate-, and high-risk disease were free of biochemical failure. Clinical and treatment parameters predictive of biochemical outcome included: clinical stage, pretreatment prostate-specific antigen (PSA), Gleason score, risk group, age > 65 years, and neoadjuvant hormonal therapy. Isotope choice was

  4. Long-Term Results of Brachytherapy With Temporary Iodine-125 Seeds in Children With Low-Grade Gliomas

    International Nuclear Information System (INIS)

    Korinthenberg, Rudolf; Neuburger, Daniela; Trippel, Michael; Ostertag, Christoph; Nikkhah, Guido

    2011-01-01

    Purpose: To retrospectively review the results of temporary I-125 brachytherapy in 94 children and adolescents with low-grade glioma. Methods and Materials: Treatment was performed in progressive tumors roughly spherical in shape with a diameter of up to 5 cm, including 79 astrocytomas, 5 oligodendrogliomas, 4 oligoastrocytomas, 1 ependymoma, and 5 other tumors. Location was suprasellar/chiasmal in 44, thalamic/basal ganglia in 18, hemispheric in 15, midbrain/pineal region in 13, and lower brainstem in 3. Initially, 8% of patients were free of symptoms, 47% were symptomatic but not disabled, and 30% were slightly, 6% moderately, and 3% severely disabled. Results: 5- and 10-year survival was 97% and 92%. The response to I-125 brachytherapy over the long term was estimated after a median observation period of 38.4 (range, 6.4-171.0) months. At that time, 4 patients were in complete, 27 in partial, and 18 in objective remission; 15 showed stable and 30 progressive tumors. Treatment results did not correlate with age, sex, histology, tumor size, location, or demarcation of the tumor. Secondary treatment became necessary in 36 patients, including 19 who underwent repeated I-125 brachytherapy. At final follow-up, the number of symptom-free patients had risen to 21%. Thirty-eight percent showed symptoms without functional impairment, 19% were slightly and 11% moderately disabled, and only 4% were severely disabled. Conclusions: Response rates similar to those of conventional radiotherapy or chemotherapy can be anticipated with I-125 brachytherapy in tumors of the appropriate size and shape. We believe it to be a useful contribution to the treatment of low-grade gliomas in children.

  5. Impact of pre-implant lower urinary tract symptoms on postoperative urinary morbidity after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Teishima, Jun; Iwamoto, Hideo; Miyamoto, Katsutoshi; Shoji, Koichi; Masumoto, Hiroshi; Inoue, Shogo; Kobayashi, Kanao; Kajiwara, Mitsuru; Matsubara, Akio

    2012-01-01

    The objectives of this study was to assess the impact of baseline lower urinary tract symptoms on postoperative urinary morbidity in patients being treated for prostate cancer with 125-I permanent prostate brachytherapy. A total of 104 prostate cancer patients were enrolled in this study. Their urinary morbidity was followed up using the International Prostate Symptom Score and Expanded Prostate Cancer Index Composite for 12 months or more after permanent prostate brachytherapy. Patients were classified into two groups based on their baseline International Prostate Symptom Score: the low International Prostate Symptom Score group (score≤7) and the high International Prostate Symptom Score group (score≥8). Urinary morbidity was estimated in each group based on the results of the International Prostate Symptom Score and Expanded Prostate Cancer Index Composite measured before permanent prostate brachytherapy, and at 1, 3, 6, 9 and 12 months after the end of all radiation therapy. The overall mean total International Prostate Symptom Score, International Prostate Symptom Score quality of life score, and urinary-related scores for Expanded Prostate Cancer Index Composite were significantly worse at 1 month after the end of treatment, but they improved gradually after the treatment and recovered to the baseline level within 12 months. Even in the high-International Prostate Symptom Score group, the International Prostate Symptom Score and International Prostate Symptom Score Quality of Life score were significantly worse at 1-3 months after permanent prostate brachytherapy, and then recovered to the baseline level without prolongation. Although the urination-related Expanded Prostate Cancer Index Composite score in the high-International Prostate Symptom Score group was significantly worse at 1 month after permanent prostate brachytherapy in comparison with that in the low-International Prostate Symptom Score group, it recovered to the baseline level without

  6. Analysis of prostate-specific antigen bounce after I125 permanent seed implant for localised prostate cancer

    International Nuclear Information System (INIS)

    Mitchell, Darren M.; Swindell, Ric; Elliott, Tony; Wylie, James P.; Taylor, Cathy M.; Logue, John P.

    2008-01-01

    Background and purpose: To report on the incidence of benign prostate-specific antigen bounce following permanent I 125 prostate brachytherapy, to describe the associations in our population and review the relationship of bounce to subsequent biochemical failure. Materials and methods: From February 2000 to May 2005, 374 patients with localised prostate cancer were treated with I 125 permanent prostate brachytherapy at a single institution. A prospectively collected database was used to identify cases of prostate-specific antigen (PSA) bounce, defined as a rise of ≥0.2 ng/ml above an initial PSA nadir with subsequent decline to or below that nadir without treatment. The patients who received neo-adjuvant or adjuvant hormone manipulation were excluded. Biochemical failure was determined using the both the ASTRO consensus definition and Phoenix (nadir +2 ng/mL) definition. Results: Two hundred and five patients were identified with a median follow-up of 45 months (24-85). PSA bounce was noted in 79 (37%) men, occurring at a median of 14.8 months (1.7-40.6) following implant. The median peak PSA was 1.8 ng/ml (0.4-7.4) with a bounce magnitude of 0.91 ng/ml (0.2-5.8). When pre- and post-implant factors were assessed for association to bounce, only younger age was statistically significant (p = 0.002). The threshold for biochemical failure as defined by the ASTRO consensus definition (1997) was met in 4 (5%) patients after experiencing bounce as opposed to 19 (15%) non-bounce patients (p = 0.01). The threshold for Phoenix (nadir +2 ng/mL) was met in 6 (7.5%) patients following bounce versus 22 (17%) of non-bounce patients (p = 0.003). Both definitions are prone to false positive calls during bounce. Median PSA velocity during the bounce was 0.08 ng/mL/month (0.02-0.98) and was statistically significantly lower than the median velocity prior to the Phoenix biochemical failure at 0.28 ng/mL/month (0.07-2.04) (p = 0.0005). Conclusion: PSA bounce is a common finding in

  7. Radiation protection after interstitial permanent prostate brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Pirraco, R.; Pereira, A.; Cavaco, A. [Instituto Portugues de Oncologia Francisco Gentil - Centro R egional de Oncologia do Porto, SA, Porto (Portugal)

    2006-07-01

    Full text of publication follows: In this study we measure patients radiation exposure dose after interstitial {sup 125}I permanent prostate Brachytherapy implants, and correlate it with dose limits for public, total activity implanted, patient preoperative weight(1), distance between prostate walls and anterior skin surface. Methods and Material: We analyse 20 patients who were implanted with {sup 125}I seeds. The instrument used to measure radiation is a calibrated Berthold Umo LB 123 aco-plated to a LB 1236-H10 detector. Three measurements were taken: at the perineal and anterior pelvic zones on contact with the skin and at 1 m from the patient. The maximum value was taken for all measurements. The dose at a distance of one meter is obtained at anterior pelvic zone, perpendicular to the skin, according to the recommendations of A.A.P.M.(1). The distance between prostate walls was determined using post -operative CT images. Results: The doses at the perineal zone have determined an average of 186 {mu}Sv/h (range: 110 340 {mu}Sv/h) and at surface pelvic zone of 41 {mu}Sv/h (range: 15 103 {mu}Sv/h). The dose at a distance of 1 meter has an average value of 0.4 {mu}Sv/h (range: 0.2 1.0 {mu}Sv/h). The average total activity implanted was 25 mCi (range: 17 38 mCi). The distance between prostate walls and skin pelvic surface of the patients has an average value of 8.9 cm (range: 6.6 -11.5 cm). At a distance of 1 meter from the pelvic zone the dose measured is very low and below dose limits imposed by the European Directive EURATOM 2 and the Portuguese law. For general public to reach annual dose limit (EURATOM - 1 mSv/year) when contacting the pelvic zone, we extrapolate that 4 days (range: 1.6 11.1 days) would be needed, assuming a daily contact period of 6 hours. Conclusion: We established a correlation between the distance of prostate walls to the skin perineal surface and the total dose, but we find no correlation between measured doses, total activity implanted

  8. Prostate brachytherapy seed migration to the heart seen on cardiovascular computed tomographic angiography

    Directory of Open Access Journals (Sweden)

    Shilpa Sachdeva, MD

    2017-03-01

    Full Text Available Brachytherapy consists of placing radioactive sources into or adjacent to tumors, to deliver conformal radiation treatment. The technique is used for treatment of primary malignancies and for salvage in recurrent disease. Permanent prostate brachytherapy seeds are small metal implants containing radioactive sources of I-125, Pd-103, or Cs-131 encased in a titanium shell. They can embolize through the venous system to the lungs or heart and subsequently be detected by cardiovascular computed tomography. Cardiovascular imagers should be aware of the appearance of migrated seeds, as their presence in the chest is generally benign, so that unnecessary worry and testing are avoided. We report a case of a patient who underwent brachytherapy for prostate cancer and developed a therapeutic seeds embolus to the right ventricle.

  9. Reduced dose to urethra and rectum with the use of variable needle spacing in prostate brachytherapy: a potential role for robotic technology.

    Science.gov (United States)

    Vyas, Shilpa; Le, Yi; Zhang, Zhe; Armour, Woody; Song, Daniel Y

    2015-08-01

    Several robotic delivery systems for prostate brachytherapy are under development or in pre-clinical testing. One of the features of robotic brachytherapy is the ability to vary spacing of needles at non-fixed intervals. This feature may play an important role in prostate brachytherapy, which is traditionally template-based with fixed needle spacing of 0.5 cm. We sought to quantify potential reductions in the dose to urethra and rectum by utilizing variable needle spacing, as compared to fixed needle spacing. Transrectal ultrasound images from 10 patients were used by 3 experienced planners to create 120 treatment plans. Each planner created 4 plan variations per patient with respect to needle positions: (125)I fixed spacing, (125)I variable spacing, (103)Pd fixed spacing, and (103)Pd variable spacing. The primary planning objective was to achieve a prostate V100 of 100% while minimizing dose to urethra and rectum. All plans met the objective of achieving prostate V100 of 100%. Combined results for all plans show statistically significant improvements in all assessed dosimetric variables for urethra (Umax, Umean, D30, D5) and rectum (Rmax, Rmean, RV100) when using variable spacing. The dose reductions for mean and maximum urethra dose using variable spacing had p values of 0.011 and 0.024 with (103)Pd, and 0.007 and 0.029 with (125)I plans. Similarly dose reductions for mean and maximum rectal dose using variable spacing had p values of 0.007 and 0.052 with (103)Pd, and 0.012 and 0.037 with (125)I plans. The variable needle spacing achievable by the use of robotics in prostate brachytherapy allows for reductions in both urethral and rectal planned doses while maintaining prostate dose coverage. Such dosimetric advantages have the potential in translating to significant clinical benefits with the use of robotic brachytherapy.

  10. Evolution of different reaction methods resulting in the formation of AgI125 for use in brachytherapy sources

    International Nuclear Information System (INIS)

    Souza, C.D.; Peleias Jr, F.S.; Rostelato, M.E.C.M.; Zeituni, C.A.; Benega, M.A.G.; Tiezzi, R.; Mattos, F.R.; Rodrigues, B.T.; Oliveira, T.B.; Feher, A.; Moura, J.A.; Costa, O.L.

    2014-01-01

    Prostate cancer represents about 10% of all cases of cancer in the world. Brachytherapy has been extensively used in the early and intermediate stages of the illness. The radiotherapy method reduces the damage probability to surrounding healthy tissues. The present study compares several deposition methods of iodine-125 on silver substrate (seed core), in order to choose the most suitable one to be implemented at IPEN. Four methods were selected: method 1 (assay based on electrodeposition) which presented efficiency of 65.16%; method 2 (assay based on chemical reactions, developed by David Kubiatowicz) which presented efficiency of 70.80%; method 3 (chemical reaction based on the methodology developed by Dr. Maria Elisa Rostelato) which presented efficiency of 55.80%; new method developed by IPEN with 90.5% efficiency. Based on the results, the new method is the suggested one to be implemented. (authors)

  11. Hospitalary inventory of prostatic sources of I-125

    International Nuclear Information System (INIS)

    Barquero Sanz, R.; Anton, D.; Frutos Baraja, J. de.; Castillo Belmonte, A. del; Alonso, D.; Miquel, D. de; Lopez Lara-Martin, F.

    2013-01-01

    In accordance with the current regulations for radioactive facilities of brachytherapy, to carry out treatments of Prostate with I-125, must be a safety study involving evaluate maximum sources activity to use in the implants. In our installation was requested to perform implants permanent interstitial in prostate patients who tend to leaving the hospital in the hours following the intervention. The request which was prepared taking into account the maximum number predictable treatment (two per week), and to determine the activity to request, it was made the removal of seeds surplus by the supplier after each treatment. (Author)

  12. Radiation exposure after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Cattani, Federica; Vavassori, Andrea; Polo, Alfredo; Rondi, Elena; Cambria, Raffaella; Orecchia, Roberto; Tosi, Giampiero

    2006-01-01

    Background and purpose: Limited information is available on the true radiation exposure and associated risks for the relatives of the patients submitted to prostate brachytherapy with permanent implant of radioactive sources and for any other people coming into contact with them. In order to provide appropriate information, we analyzed the radiation exposure data from 216 prostate cancer patients who underwent 125 I or 103 Pd implants at the European Institute of Oncology of Milan, Italy. Patients and methods: Between October 1999 and October 2004, 216 patients with low risk prostate carcinoma were treated with 125 I (200 patients) or 103 Pd (16 patients) permanent seed implantation. One day after the procedure, radiation exposure measurements around the patients were performed using an ionization chamber survey meter (Victoreen RPO-50) calibrated in dose rate at an accredited calibration center (calibration Centre SIT 104). Results: The mean dose rate at the posterior skin surface (gluteal region) following 125 I implants was 41.3 μSv/h (range: 6.2-99.4 μSv/h) and following 103 Pd implants was 18.9 μSv/h (range 5.0-37.3 μSv/h). The dose rate at 50 cm from the skin decreased to the mean value of 6.4 μSv/h for the 125 I implants and to the mean value of 1.7 μSv/h for the 103 Pd implants. Total times required to reach the annual dose limit (1 mSv/year) recommended for the general population by the European Directive 96/29/Euratom and by the Italian law (Decreto Legislativo 241/2000) at a distance of 50 cm from the posterior skin surface of the implanted patient would be 7.7 and 21.6 days for 125 I and for 103 Pd. Good correlation between the measured dose rates and both the total implanted activity and the distance between the most posteriorly implanted seed and the skin surface of the patients was found. Conclusions: Our data show that the dose rates at 50 cm away from the prostate brachytherapy patients are very low and that the doses possibly absorbed by the

  13. Placement of empty catheters for an HDR-emulating LDR prostate brachytherapy technique: comparison to standard intraoperative planning.

    Science.gov (United States)

    Niedermayr, Thomas R; Nguyen, Paul L; Murciano-Goroff, Yonina R; Kovtun, Konstantin A; Neubauer Sugar, Emily; Cail, Daniel W; O'Farrell, Desmond A; Hansen, Jorgen L; Cormack, Robert A; Buzurovic, Ivan; Wolfsberger, Luciant T; O'Leary, Michael P; Steele, Graeme S; Devlin, Philip M; Orio, Peter F

    2014-01-01

    We sought to determine whether placing empty catheters within the prostate and then inverse planning iodine-125 seed locations within those catheters (High Dose Rate-Emulating Low Dose Rate Prostate Brachytherapy [HELP] technique) would improve concordance between planned and achieved dosimetry compared with a standard intraoperative technique. We examined 30 consecutive low dose rate prostate cases performed by standard intraoperative technique of planning followed by needle placement/seed deposition and compared them to 30 consecutive low dose rate prostate cases performed by the HELP technique. The primary endpoint was concordance between planned percentage of the clinical target volume that receives at least 100% of the prescribed dose/dose that covers 90% of the volume of the clinical target volume (V100/D90) and the actual V100/D90 achieved at Postoperative Day 1. The HELP technique had superior concordance between the planned target dosimetry and what was actually achieved at Day 1 and Day 30. Specifically, target D90 at Day 1 was on average 33.7 Gy less than planned for the standard intraoperative technique but was only 10.5 Gy less than planned for the HELP technique (p 0.05). Placing empty needles first and optimizing the plan to the known positions of the needles resulted in improved concordance between the planned and the achieved dosimetry to the target, possibly because of elimination of errors in needle placement. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. The american brachytherapy society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis

    International Nuclear Information System (INIS)

    Nag, Subir; Bice, William; Wyngaert, Keith de; Prestidge, Bradley; Stock, Richard; Yu Yan

    2000-01-01

    Purpose: The purpose of this report is to establish guidelines for postimplant dosimetric analysis of permanent prostate brachytherapy. Methods: Members of the American Brachytherapy Society (ABS) with expertise in prostate dosimetry evaluation performed a literature review and supplemented with their clinical experience formulated guidelines for performing and analyzing postimplant dosimetry of permanent prostate brachytherapy. Results: The ABS recommends that postimplant dosimetry should be performed on all patients undergoing permanent prostate brachytherapy for optimal patient care. At present, computed tomography (CT)-based dosimetry is recommended, based on availability cost and the ability to image the prostate as well as the seeds. Additional plane radiographs should be obtained to verify the seed count. Until the ideal postoperative interval for CT scanning has been determined, each center should perform dosimetric evaluation of prostate implants at a consistent postoperative interval. This interval should be reported. Isodose displays should be obtained at 50%, 80%, 90%, 100%, 150%, and 200% of the prescription dose and displayed on multiple cross-sectional images of the prostate. A dose-volume histogram (DVH) of the prostate should be performed and the D 90 (dose to 90% of the prostate gland) reported by all centers. Additionally, the D 80, D 100, the fractional V 80, V 90, V 100, V 150, and V 200, (i.e., the percentage of prostate volume receiving 80%, 90%, 100%, 150%, and 200% of the prescribed dose, respectively), the rectal, and urethral doses should be reported and ultimately correlated with clinical outcome in the research environment. On-line real-time dosimetry, the effects of dose heterogeneity, and the effects of tissue heterogeneity need further investigation. Conclusion: It is essential that postimplant dosimetry should be performed on all patients undergoing permanent prostate brachytherapy. Guidelines were established for the performance

  15. Treatment of localized prostate cancer with brachytherapy: six years experience

    International Nuclear Information System (INIS)

    Martinez, Pablo; Dourado, Leandro; Giudice, Carlos; Villamil, Wenceslao; Palacios, Victor; Sardi, Mabel; Damia, Oscar

    2006-01-01

    The usage of ultrasound scan to perform prostate biopsy punctures, the new radiation therapies and the more accurate selection of patients has allowed brachytherapy to play an important role in the treatment of the localized pathology. The objective of this paper is to review the results obtained when treating the localized prostate cancer by using brachytherapy with mud 125. Materials and methods: Between December 1999 and July 2006, 100 prostate cancer patients were treated at the Hospital Italiano de Buenos Aires, using brachytherapy with mud 125. One of the patients was treated with a combined therapy (brachytherapy + external radiotherapy). For that reason, the patient was not taken into consideration for this paper. The average age was 65.95 (52-79). The tumoral stages were T1c in 81% of the patients and T2a in 19% of them. The PSA was always below 15 ng/ml, with an average of 8.92 ng/ml; inferior to 10 ng/ml in 72 patients and between 10 and 15 ng/m ml in 28 of them. The average prostate volume was 34.68 c.c. (18.70 c.c.-58.00 c.c.). The combined Gleason score was below 6 (except for three patients with Gleason 7 who had a PSA below 10, stage T1c). The dose used was 16,000 cGy as recommended by the TG43. The energy charge of each seed was between 0.28 and 0.40 mci. Thirty days later, a prostate axial computer tomography was carried out every 3 mm. with a scanning set every 5 mm. to perform a dosimetric control of the implant. Results: The average age was 65.95 (52-79). The control computer tomography showed an adequate dosimetric coverage for the entire prostate volume, with a maximum urethral dose not above 400 Gy and a maximum rectal dose below 100 Gy. The PSA of all patients decreased to a normal level 6 months after the treatment started. The average follow-up of the 71 patients able to be tested from an oncological perspective lasted 31.15 months, with a minimum of 18 and a maximum of 72 months. Currently, seven patients of those tested (9.86%) manifest

  16. Low dose rate brachytherapy (LDR-BT) as monotherapy for early stage prostate cancer in Italy: practice and outcome analysis in a series of 2237 patients from 11 institutions.

    Science.gov (United States)

    Fellin, Giovanni; Mirri, Maria A; Santoro, Luigi; Jereczek-Fossa, Barbara A; Divan, Claudio; Mussari, Salvatore; Ziglio, Francesco; La Face, Beniamino; Barbera, Fernando; Buglione, Michela; Bandera, Laura; Ghedi, Barbara; Di Muzio, Nadia G; Losa, Andrea; Mangili, Paola; Nava, Luciano; Chiarlone, Renato; Ciscognetti, Nunzia; Gastaldi, Emilio; Cattani, Federica; Spoto, Ruggero; Vavassori, Andrea; Giglioli, Francesca R; Guarneri, Alessia; Cerboneschi, Valentina; Mignogna, Marcello; Paoluzzi, Mauro; Ravaglia, Valentina; Chiumento, Costanza; Clemente, Stefania; Fusco, Vincenzo; Santini, Roberto; Stefanacci, Marco; Mangiacotti, Francesco P; Martini, Marco; Palloni, Tiziana; Schinaia, Giuseppe; Lazzari, Grazia; Silvano, Giovanni; Magrini, Stefano; Ricardi, Umberto; Santoni, Riccardo; Orecchia, Roberto

    2016-09-01

    Low-dose-rate brachytherapy (LDR-BT) in localized prostate cancer is available since 15 years in Italy. We realized the first national multicentre and multidisciplinary data collection to evaluate LDR-BT practice, given as monotherapy, and outcome in terms of biochemical failure. Between May 1998 and December 2011, 2237 patients with early-stage prostate cancer from 11 Italian community and academic hospitals were treated with iodine-125 ((125)I) or palladium-103 LDR-BT as monotherapy and followed up for at least 2 years. (125)I seeds were implanted in 97.7% of the patients: the mean dose received by 90% of target volume was 145 Gy; the mean target volume receiving 100% of prescribed dose (V100) was 91.1%. Biochemical failure-free survival (BFFS), disease-specific survival (DSS) and overall survival (OS) were estimated using Kaplan-Meier method. Log-rank test and multivariable Cox regression were used to evaluate the relationship of covariates with outcomes. Median follow-up time was 65 months. 5- and 7-year DSS, OS and BFFS were 99 and 98%, 94 and 89%, and 92 and 88%, respectively. At multivariate analysis, the National Comprehensive Cancer Network score (p LDR-BT. This first multicentre Italian report confirms LDR-BT as an excellent curative modality for low-/intermediate-risk prostate cancer. Multidisciplinary teams may help to select adequately patients to be treated with brachytherapy, with a direct impact on the implant quality and, possibly, on outcome.

  17. Dosimetry on ocular brachytherapy with ROPES plaque with Iodine-125 and Palladium-103 seeds; Dosimetria em braquiterapia ocular com placa ROPES contendo sementes de iodo-125 e paladium-103

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar], e-mail: aprata@des.cefetmg.br; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares

    2010-03-15

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departuring absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational model of ocular area was developed to simulate orbital irradiation with ROPES ophthalmologic plaque placed on the sclera surface filled to ten iodine-125 seeds, and palladium-103 seeds. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy. (author)

  18. [Brachytherapy of brainstem tumors].

    Science.gov (United States)

    Julow, Jenö; Viola, Arpád; Major, Tibor; Valálik, István; Sági, Sarolta; Mangel, László; Kovács, Rita Beáta; Repa, Imre; Bajzik, Gábor; Németh, György

    2004-01-20

    The optimal therapy of brain stem tumours of different histopathology determines the expected length of survival. Authors report 125Iodine interstitial irradiation of brain stem tumours with stereotactic brachytherapy. Two patients having brain stem tumours were suffering from glioma or from metastases of a carcinoma. In Case 1 the tumour volume was 1.98 cm3 at the time of planning interstitial irradiation. The control MRI examination performed at 42 months post-op showed a postirradiation cyst size of 5.73 cm3 indicating 65.5% shrinkage. In Case 2 the shrinkage was more apparent as the tumour volume measured on the control MRI at 8 months post-op was only 0.16 cm3 indicating 97.4% shrinkage of the 6.05 cm3 target volume at the time of brachytherapy with the metastasis practically disappearing. Quick access to histopathological results of the stereotactic intraoperative biopsy made it possible to carry out the 125Iodine stereotactic brachytherapy immediately after the biopsy, resulting in less inconvenience for patients of a second possible intervention. The control MRI scans show significant shrinkage of tumours in both patients. The procedure can be performed as a biopsy. The CT and image fusion guided 125Iodine stereotactic brachytherapy can be well planned dosimetrically and is surgically precise.

  19. Mock iodine-125 radiation source

    International Nuclear Information System (INIS)

    Coffey, D.L.

    1976-01-01

    An intimate mixture of americium-241 and iodine-129 provides an energy spectrum that reliably simulates the spectrum of iodine-125 in a well-type detector. As such, it may be used as a long-lived standard to calibrate instruments such as well scintillation spectrometers in which measurements are to be made involving iodine-125

  20. PSA bounce phenomenon after transperineal interstitial permanent prostate brachytherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Morita, Masashi; Lederer, J.L.; Fukagai, Takashi; Yoshida, Hideki; Shimada, Makoto

    2004-01-01

    We described the temporarily increase phenomenon in prostate-specific antigen level (PSA bounce) after transperineal interstitial permanent prostate brachytherapy (TIPPB) for localized prostate cancer. From December 1998 to May 2003, 500 consecutive patients with localized prostate cancer were treated with TIPPB using iodine-125 or palladium-103. We examined 200 patients who have more than 2-year PSA follow-up. Median follow-up length was 1,069 days (range, 712-1,411 days). No patient received neoadjuvant or adjuvant hormone therapy. PSA determinations were performed every 3 months for the first 2 years after procedure, and every 6 months hereafter. PSA bounce was defined as an increase of 0.1 ng/ml or greater above the preceding PSA level after implant followed by a subsequent decrease below that level. The American Society for Therapeutic Radiology and Oncology (ASTRO) consensus panel criteria 1996 were used to define biochemical failure. PSA bounce was observed in 40% (80/200) of the cases receiving TIPPB. The median time to PSA bounce was 13 months from the day of implant. The median magnitude of the PSA bounce was 0.3 ng/ml from the pre-bounce level. Twelve cases demonstrated biochemical failure according to the ASTRO consensus guidelines of three consecutive rises in PSA. Ten of these subsequently showed a drop in PSA, consistent with biologic control of their disease. Two cases remain classified as apparent biochemical failures. A transient rise in the PSA following TIPPB, the so-called ''bounce'' is a common occurrence. The apparent PSA control of ten of twelve cases failing by the ASTRO criteria raises some concern. Further observation will be necessary to determine ways to discriminate these from true disease progression. (author)

  1. Permanent Prostate Brachytherapy in Prostate Glands 3

    International Nuclear Information System (INIS)

    Mayadev, Jyoti; Merrick, Gregory S.; Reed, Joshua R.; Butler, Wayne M.; Galbreath, Robert W.; Allen, Zachariah A.; Wallner, Kent E.

    2010-01-01

    Purpose: To investigate the dosimetry, treatment-related morbidity, and biochemical outcomes for brachytherapy in patients with prostate glands 3 . Methods and Materials: From November 1996 to October 2006, 104 patients with prostate glands 3 underwent brachytherapy. Multiple prostate, urethral, and rectal dosimetric parameters were evaluated. Treatment-related urinary and rectal morbidity were assessed from patient questionnaires. Cause-specific survival, biochemical progression-free survival, and overall survival were recorded. Results: The median patient age, follow up, and pre-treatment ultrasound volume was 64 years, 5.0 years and 17.6cm 3 , respectively. Median day 0 dosimetry was significant for the following: V100 98.5%, D90 126.1% and R100 <0.5% of prescription dose. The mean urethral and maximum urethral doses were 119.6% and 133.8% of prescription. The median time to International Prostate Symptom Score resolution was 4 months. There were no RTOG grade III or IV rectal complications. The cause-specific survival, biochemical progression-free survival, and overall survival rates were 100%, 92.5%, and 77.8% at 9 years. For biochemically disease-free patients, the median most recent postbrachytherapy PSA value was 0.02 ng/mL. Conclusion: Our results demonstrate that brachytherapy for small prostate glands is highly effective, with an acceptable morbidity profile, excellent postimplant dosimetry, acceptable treatment-related morbidity, and favorable biochemical outcomes.

  2. Methods for prostate stabilization during transperineal LDR brachytherapy.

    Science.gov (United States)

    Podder, Tarun; Sherman, Jason; Rubens, Deborah; Messing, Edward; Strang, John; Ng, Wan-Sing; Yu, Yan

    2008-03-21

    In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and

  3. Methods for prostate stabilization during transperineal LDR brachytherapy

    International Nuclear Information System (INIS)

    Podder, Tarun; Yu Yan; Sherman, Jason; Rubens, Deborah; Strang, John; Messing, Edward; Ng, Wan-Sing

    2008-01-01

    In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and

  4. SU-E-T-397: Include Organ Deformation Into Dose Calculation of Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Shao, Y; Shen, D; Chen, R; Wang, A; Lian, J

    2014-01-01

    Purpose: Prostate brachytherapy is an important curative treatment for patients with localized prostate cancer. In brachytherapy, rectal balloon is generally needed to adjust for unfavorable prostate position for seed placement. However, rectal balloon causes prostate deformation, which is not accounted for in dosimetric planning. Therefore, it is possible that brachytherapy dosimetry deviates significantly from initial plan when prostate returns to its non-deformed state (after procedure). The goal of this study is to develop a method to include prostate deformation into the treatment planning of brachytherapy dosimetry. Methods: We prospectively collected ultrasound images of prostate pre- and post- rectal balloon inflation from thirty five consecutive patients undergoing I-125 brachytherapy. Based on the cylinder coordinate systems, we learned the initial coordinate transformation parameters between the manual segmentations of both deformed and non-deformed prostates of each patient in training set. With the nearest-neighbor interpolation, we searched the best transformation between two coordinate systems to maximum the mutual information of deformed and non-deformed images. We then mapped the implanted seeds of five selected patients from the deformed prostate into non-deformed prostate. The seed position is marked on original pre-inflation US image and it is imported into VariSeed software for dose calculation. Results: The accuracy of image registration is 87.5% as quantified by Dice Index. The prostate coverage V100% dropped from 96.5±0.5% of prostate deformed plan to 91.9±2.6% (p<0.05) of non-deformed plan. The rectum V100% decreased from 0.44±0.26 cc to 0.10±0.18 cc (p<0.05). The dosimetry of the urethra showed mild change but not significant: V150% changed from 0.05±0.10 cc to 0.14±0.15 cc (p>0.05) and D1% changed from 212.9±37.3 Gy to 248.4±42.8 Gy (p>0.05). Conclusion: We have developed a deformable image registration method that allows

  5. Seed Implant Retention Score Predicts the Risk of Prolonged Urinary Retention After Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Lee, Hoon K.; Adams, Marc T.; Shi, Qiuhu; Basillote, Jay; LaMonica, Joanne; Miranda, Luis; Motta, Joseph

    2010-01-01

    Purpose: To risk-stratify patients for urinary retention after prostate brachytherapy according to a novel seed implant retention score (SIRS). Patients and Methods: A total of 835 patients underwent transperineal prostate seed implant from March 1993 to January 2007; 197 patients had 125 I and 638 patients had 103 Pd brachytherapy. Four hundred ninety-four patients had supplemental external-beam radiation. The final downsized prostate volume was used for the 424 patients who had neoadjuvant hormone therapy. Retention was defined as reinsertion of a Foley catheter after the implant. Results: Retention developed in 7.4% of patients, with an average duration of 6.7 weeks. On univariate analysis, implant without supplemental external-beam radiation (10% vs. 5.6%; p = 0.02), neoadjuvant hormone therapy (9.4% vs. 5.4%; p = 0.02), baseline α-blocker use (12.5% vs. 6.3%; p = 0.008), and increased prostate volume (13.4% vs. 6.9% vs. 2.9%, >45 cm 3 , 25-45 cm 3 , 3 ; p = 0.0008) were significantly correlated with increased rates of retention. On multivariate analysis, implant without supplemental external-beam radiation, neoadjuvant hormone therapy, baseline α-blocker use, and increased prostate volume were correlated with retention. A novel SIRS was modeled as the combined score of these factors, ranging from 0 to 5. There was a significant correlation between the SIRS and retention (p < 0.0001). The rates of retention were 0, 4%, 5.6%, 9%, 20.9%, and 36.4% for SIRS of 0 to 5, respectively. Conclusions: The SIRS may identify patients who are at high risk for prolonged retention after prostate brachytherapy. A prospective validation study of the SIRS is planned.

  6. Dosimetric and Late Radiation Toxicity Comparison Between Iodine-125 Brachytherapy and Stereotactic Radiation Therapy for Juxtapapillary Choroidal Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Krema, Hatem, E-mail: htmkrm19@yahoo.com [Department of Ocular Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Heydarian, Mostafa [Department of Radiation Medicine, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Beiki-Ardakani, Akbar [Department of Radiation Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Weisbrod, Daniel [Department of Ocular Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Xu, Wei [Department of Biostatistics, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Laperriere, Normand J.; Sahgal, Arjun [Department of Radiation Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada)

    2013-07-01

    Purpose: To compare the dose distributions and late radiation toxicities for {sup 125}I brachytherapy (IBT) and stereotactic radiation therapy (SRT) in the treatment of juxtapapillary choroidal melanoma. Methods: Ninety-four consecutive patients with juxtapapillary melanoma were reviewed: 30 have been treated with IBT and 64 with SRT. Iodine-125 brachytherapy cases were modeled with plaque simulator software for dosimetric analysis. The SRT dosimetric data were obtained from the Radionics XKnife RT3 software. Mean doses at predetermined intraocular points were calculated. Kaplan-Meier estimates determined the actuarial rates of late toxicities, and the log–rank test compared the estimates. Results: The median follow-up was 46 months in both cohorts. The 2 cohorts were balanced with respect to pretreatment clinical and tumor characteristics. Comparisons of radiation toxicity rates between the IBT and SRT cohorts yielded actuarial rates at 50 months for cataracts of 62% and 75% (P=.1), for neovascular glaucoma 8% and 47% (P=.002), for radiation retinopathy 59% and 89% (P=.0001), and for radiation papillopathy 39% and 74% (P=.003), respectively. Dosimetric comparisons between the IBT and SRT cohorts yielded mean doses of 12.8 and 14.1 Gy (P=.56) for the lens center, 17.6 and 19.7 Gy (P=.44) for the lens posterior pole, 13.9 and 10.8 Gy (P=.30) for the ciliary body, 61.9 and 69.7 Gy (P=.03) for optic disc center, and 48.9 and 60.1 Gy (P<.0001) for retina at 5-mm distance from tumor margin, respectively. Conclusions: Late radiation-induced toxicities were greater with SRT, which is secondary to the high-dose exposure inherent to the technique as compared with IBT. When technically feasible, IBT is preferred to treat juxtapapillary choroidal melanoma.

  7. Dosimetry on ocular brachytherapy with ROPE plaque with iodine{sub 1}25 and palladium-103;Dosimetria em braquiterapia ocular com placa ROPES contando sementes de iodo-125 e paladio-103

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica (CEFET/MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar; Campos, Tarcisio [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares

    2009-07-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departing absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational model of ocular area was developed to simulate orbital irradiation with ROPES ophthalmologic plaque placed on the sclera surface filled to ten iodine-125 seeds, and palladium-103 seeds. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy. (author)

  8. Isotope selection for patients undergoing prostate brachytherapy

    International Nuclear Information System (INIS)

    Cha, Christine M.; Potters, Louis; Ashley, Richard; Freeman, Katherine; Wang Xiaohong; Waldbaum, Robert; Leibel, Steven

    1999-01-01

    Purpose: Ultrasound-guided trans perineal interstitial permanent prostate brachytherapy (TIPPB) is generally performed with either 103 Pd or 125 I. The use of 125 I for low Gleason score tumors and 103 Pd for higher Gleason scores has been suggested based on isotope dose rate and cell doubling time observed in in vitro studies. While many centers follow these isotope selection criteria, other centers have elected to use only a single isotope, regardless of Gleason score. No clinical data have been published comparing these isotopes. This study was undertaken to compare outcomes between 125 I and 103 Pd in a matched pair analysis for patients undergoing prostate brachytherapy. Methods and Materials: Six hundred forty-eight consecutively treated patients with clinically confined prostate cancer underwent TIPPB between June 1992 and February 1997. Five hundred thirty-two patients underwent TIPPB alone, whereas 116 received pelvic external beam irradiation and TIPPB. Ninety-three patients received androgen deprivation therapy prior to TIPPB. The prescribed doses for TIPPB were 160 Gy for 125 I (pre-TG43) and 120 Gy for 103 Pd. Patients treated with combination therapy received 41.4 or 45 Gy (1.8 Gy/fraction) external beam irradiation followed by a 3- to 5-week break and then received either a 120-Gy 125 I or a 90-Gy 103 Pd implant. Until November 1994, all patients underwent an 125 I implant after which the isotope selection was based on either Gleason score (Gleason score 2-5: 125 I; Gleason 5-8: 103 Pd) or isotope availability. A matched pair analysis was performed to assess any difference between isotopes. Two hundred twenty-two patients were matched according to Gleason score, prostate-specific antigen (PSA), and stage. PSA relapse-free survival (PSA-RFS) was calculated based on the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus Group definition of failure. Kaplan-Meier actuarial survival curves were compared to assess differences in

  9. Oncological outcome, complications, lower urinary tract symptoms, and health-related quality of life after low-dose-rate salvage brachytherapy for recurrent prostate cancer following primary radiotherapy: a report of 8 cases

    Directory of Open Access Journals (Sweden)

    Makito Miyake

    2017-07-01

    Full Text Available Purpose: We evaluated our experience with low-dose-rate salvage brachytherapy for local recurrence after primary prostate radiotherapy, and described the changes in lower urinary tract symptoms and health-related quality of life. Material and methods: Between 2011 and 2016, eight men with local recurrence after primary prostate radiotherapy underwent iodine-125 salvage brachytherapy with a prescribed dose of 110 or 145 Gy. Recurrence-free survival was evaluated with a post-treatment prostate-specific antigen profile. The toxicity and changes in lower urinary tract symptoms and health-related quality of life during the follow-up were evaluated on the Common Terminology Criteria for Adverse Events version 4.0, International Prostate Symptom Score, Short Form-8, and Expanded Prostate Cancer Index Composite, respectively. Results: The median follow-up was 12.2 months (range, 8.3-71.9 after salvage brachytherapy. Of all eight patients, two (25% experienced treatment failure, one of whom developed left seminal vesicle recurrence 36 months after salvage brachytherapy for the right seminal vesicle recurrence, while the other developed bone metastases after 6 months. The International Prostate Symptom Scores peaked at 3 months, and returned to baseline by 6 months. The scores of all domains of health-related quality of life remained unchanged during the 12-month follow-up after salvage brachytherapy. Early grade ≤ 2 genitourinary toxicity was observed in five patients (63%, and late grade 2 gastrointestinal toxicity in one patient (13% having persistent diarrhea. No patient required intermittent catheterization and no grade 3 or greater toxicity occurred during follow-up. Conclusions: The present study is our experiment of eight patients undergoing salvage brachytherapy, suggesting that this modality is noninvasive, safe, and an effective salvage local treatment in selected patients. To our knowledge, this is the first study to evaluate lower urinary

  10. LDR vs. HDR brachytherapy for localized prostate cancer: the view from radiobiological models.

    Science.gov (United States)

    King, Christopher R

    2002-01-01

    Permanent LDR brachytherapy and temporary HDR brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never be conducted comparing these two forms of brachytherapy, a comparative radiobiological modeling analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. Radiobiological models based upon the linear quadratic equations are presented for fractionated external beam, fractionated (192)Ir HDR brachytherapy, and (125)I and (103)Pd LDR brachytherapy. These models incorporate the dose heterogeneities present in brachytherapy based upon patient-derived dose volume histograms (DVH) as well as tumor doubling times and repair kinetics. Radiobiological parameters are normalized to correspond to three accepted clinical risk factors based upon T-stage, PSA, and Gleason score to compare models with clinical series. Tumor control probabilities (TCP) for LDR and HDR brachytherapy (as monotherapy or combined with external beam) are compared with clinical bNED survival rates. Predictions are made for dose escalation with HDR brachytherapy regimens. Model predictions for dose escalation with external beam agree with clinical data and validate the models and their underlying assumptions. Both LDR and HDR brachytherapy achieve superior tumor control when compared with external beam at conventional doses (LDR brachytherapy as boost achieves superior tumor control than when used as monotherapy. Stage for stage, both LDR and current HDR regimens achieve similar tumor control rates, in agreement with current clinical data. HDR monotherapy with large-dose fraction sizes might achieve superior tumor control compared with LDR, especially if prostate cancer possesses a high sensitivity to dose fractionation (i.e., if the alpha/beta ratio is low). Radiobiological models support the current clinical evidence for equivalent outcomes in localized

  11. Reduced dose to urethra and rectum with the use of variable needle spacing in prostate brachytherapy: a potential role for robotic technology

    Science.gov (United States)

    Vyas, Shilpa; Le, Yi; Zhang, Zhe; Armour, Woody

    2015-01-01

    Purpose Several robotic delivery systems for prostate brachytherapy are under development or in pre-clinical testing. One of the features of robotic brachytherapy is the ability to vary spacing of needles at non-fixed intervals. This feature may play an important role in prostate brachytherapy, which is traditionally template-based with fixed needle spacing of 0.5 cm. We sought to quantify potential reductions in the dose to urethra and rectum by utilizing variable needle spacing, as compared to fixed needle spacing. Material and methods Transrectal ultrasound images from 10 patients were used by 3 experienced planners to create 120 treatment plans. Each planner created 4 plan variations per patient with respect to needle positions: 125I fixed spacing, 125I variable spacing, 103Pd fixed spacing, and 103Pd variable spacing. The primary planning objective was to achieve a prostate V100 of 100% while minimizing dose to urethra and rectum. Results All plans met the objective of achieving prostate V100 of 100%. Combined results for all plans show statistically significant improvements in all assessed dosimetric variables for urethra (Umax, Umean, D30, D5) and rectum (Rmax, Rmean, RV100) when using variable spacing. The dose reductions for mean and maximum urethra dose using variable spacing had p values of 0.011 and 0.024 with 103Pd, and 0.007 and 0.029 with 125I plans. Similarly dose reductions for mean and maximum rectal dose using variable spacing had p values of 0.007 and 0.052 with 103Pd, and 0.012 and 0.037 with 125I plans. Conclusions The variable needle spacing achievable by the use of robotics in prostate brachytherapy allows for reductions in both urethral and rectal planned doses while maintaining prostate dose coverage. Such dosimetric advantages have the potential in translating to significant clinical benefits with the use of robotic brachytherapy. PMID:26622227

  12. Influence of radioactive sources discretization in the Monte Carlo computational simulations of brachytherapy procedures: a case study on the procedures for treatment of prostate cancer; Influencia da discretizacao das fontes radioativas nas simulacoes computacionais Monte Carlo de procedimentos de braquiterapia: um estudo de caso sobre os procedimentos para tratamento do cancer de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson [Instituto Federal de Educacao, Ciencia e Tecnologia (IFPE), Recife, PE (Brazil); Costa, Kleber Souza Silva [Faculdade Integrada de Pernambuco (FACIPE), Recife, PE (Brazil); Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-07-01

    Radiotherapy computational simulation procedures using Monte Carlo (MC) methods have shown to be increasingly important to the improvement of cancer fighting strategies. One of the biases in this practice is the discretization of the radioactive source in brachytherapy simulations, which often do not match with a real situation. This study had the aim to identify and to measure the influence of radioactive sources discretization in brachytherapy MC simulations when compared to those that do not present discretization, using prostate brachytherapy with Iodine-125 radionuclide as model. Simulations were carried out with 108 events with both types of sources to compare them using EGSnrc code associated to MASH phantom in orthostatic and supine positions with some anatomic adaptations. Significant alterations were found, especially regarding bladder, rectum and the prostate itself. It can be concluded that there is a need to discretized sources in brachytherapy simulations to ensure its representativeness. (author)

  13. Hospitalary inventory of prostatic sources of I-125; Inventario hospitalario de fuentes prostaticas de I-125

    Energy Technology Data Exchange (ETDEWEB)

    Barquero Sanz, R.; Anton, D.; Frutos Baraja, J. de.; Castillo Belmonte, A. del; Alonso, D.; Miquel, D. de; Lopez Lara-Martin, F.

    2013-07-01

    In accordance with the current regulations for radioactive facilities of brachytherapy, to carry out treatments of Prostate with I-125, must be a safety study involving evaluate maximum sources activity to use in the implants. In our installation was requested to perform implants permanent interstitial in prostate patients who tend to leaving the hospital in the hours following the intervention. The request which was prepared taking into account the maximum number predictable treatment (two per week), and to determine the activity to request, it was made the removal of seeds surplus by the supplier after each treatment. (Author)

  14. Brachytherapy Application With In Situ Dose Painting Administered by Gold Nanoparticle Eluters

    International Nuclear Information System (INIS)

    Sinha, Neeharika; Cifter, Gizem; Sajo, Erno; Kumar, Rajiv; Sridhar, Srinivas; Nguyen, Paul L.; Cormack, Robert A.; Makrigiorgos, G. Mike; Ngwa, Wilfred

    2015-01-01

    Purpose: Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A new strategy proposed for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in situ release after implantation. This in silico study investigated the intratumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials: An experimentally determined intratumoral diffusion coefficient (D) for 10-nm nanoparticles was used to estimate D for other sizes by using the Stokes-Einstein equation. GNP concentration profiles, obtained using D, were then used to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel, using dose painting-by-numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation was carried out as a function of GNP size for the clinically applicable low-dose-rate brachytherapy sources iodine-125 (I-125), palladium-103 (Pd-103), and cesium-131 (Cs-131). Results: Results showed that dose enhancement to tumor voxels and subvolumes during brachytherapy can be customized by varying the size of GNP released or eluted from the GBS. For example, using a concentration of 7 mg/g GNP, significant DEF (>20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNP sizes of 2, 5, 10, 20, 30, and 50 nm and for 80 nm when treating with I-125. Conclusions: Analyses showed that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. These findings provide a useful reference for further work toward development of potential new brachytherapy application

  15. Brachytherapy Application With In Situ Dose Painting Administered by Gold Nanoparticle Eluters

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Neeharika [Department of Sciences, Wentworth Institute of Technology, Boston, Massachusetts (United States); Cifter, Gizem [Department of Physics and Applied Physics, University of Massachusetts, Lowell, Massachusetts (United States); Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Sajo, Erno [Department of Physics and Applied Physics, University of Massachusetts, Lowell, Massachusetts (United States); Kumar, Rajiv; Sridhar, Srinivas [Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Electronic Materials Research Institute and Department of Physics, Northeastern University, Boston, Massachusetts (United States); Nguyen, Paul L.; Cormack, Robert A.; Makrigiorgos, G. Mike [Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Ngwa, Wilfred, E-mail: wngwa@lroc.harvard.edu [Department of Physics and Applied Physics, University of Massachusetts, Lowell, Massachusetts (United States); Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States)

    2015-02-01

    Purpose: Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A new strategy proposed for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in situ release after implantation. This in silico study investigated the intratumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials: An experimentally determined intratumoral diffusion coefficient (D) for 10-nm nanoparticles was used to estimate D for other sizes by using the Stokes-Einstein equation. GNP concentration profiles, obtained using D, were then used to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel, using dose painting-by-numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation was carried out as a function of GNP size for the clinically applicable low-dose-rate brachytherapy sources iodine-125 (I-125), palladium-103 (Pd-103), and cesium-131 (Cs-131). Results: Results showed that dose enhancement to tumor voxels and subvolumes during brachytherapy can be customized by varying the size of GNP released or eluted from the GBS. For example, using a concentration of 7 mg/g GNP, significant DEF (>20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNP sizes of 2, 5, 10, 20, 30, and 50 nm and for 80 nm when treating with I-125. Conclusions: Analyses showed that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. These findings provide a useful reference for further work toward development of potential new brachytherapy application

  16. Interstitially implanted I125 for prostate cancer using transrectal ultrasound

    International Nuclear Information System (INIS)

    Greenburg, S.; Petersen, J.; Hansen-Peters, I.; Baylinson, W.

    1990-01-01

    Prostate cancer is the third leading cause of death from cancer among men in the United States. Traditional treatments for prostate cancer are prostatectomy, external beam irradiation, and interstitial implantation of Iodine125 (I125) via laparotomy. These treatments are associated with significant morbidity and limitations. Based on experience with I125 interstitial implantation by transrectal ultrasound guidance for early-stage prostate cancer, it seems that this newer method of treatment has greater accuracy of placement and distribution of the isotope and has had few reported complications. The need for a surgical incision has been eliminated. Hospitalization time also has been decreased, creating the need for ambulatory and inpatient nurses to understand the importance of their respective roles in providing coordinated quality care for these patients. Nurses in these departments must have knowledge of the procedure, radiation safety, and common side effects related to the implant

  17. Inverse treatment planning based on MRI for HDR prostate brachytherapy

    International Nuclear Information System (INIS)

    Citrin, Deborah; Ning, Holly; Guion, Peter; Li Guang; Susil, Robert C.; Miller, Robert W.; Lessard, Etienne; Pouliot, Jean; Xie Huchen; Capala, Jacek; Coleman, C. Norman; Camphausen, Kevin; Menard, Cynthia

    2005-01-01

    Purpose: To develop and optimize a technique for inverse treatment planning based solely on magnetic resonance imaging (MRI) during high-dose-rate brachytherapy for prostate cancer. Methods and materials: Phantom studies were performed to verify the spatial integrity of treatment planning based on MRI. Data were evaluated from 10 patients with clinically localized prostate cancer who had undergone two high-dose-rate prostate brachytherapy boosts under MRI guidance before and after pelvic radiotherapy. Treatment planning MRI scans were systematically evaluated to derive a class solution for inverse planning constraints that would reproducibly result in acceptable target and normal tissue dosimetry. Results: We verified the spatial integrity of MRI for treatment planning. MRI anatomic evaluation revealed no significant displacement of the prostate in the left lateral decubitus position, a mean distance of 14.47 mm from the prostatic apex to the penile bulb, and clear demarcation of the neurovascular bundles on postcontrast imaging. Derivation of a class solution for inverse planning constraints resulted in a mean target volume receiving 100% of the prescribed dose of 95.69%, while maintaining a rectal volume receiving 75% of the prescribed dose of <5% (mean 1.36%) and urethral volume receiving 125% of the prescribed dose of <2% (mean 0.54%). Conclusion: Systematic evaluation of image spatial integrity, delineation uncertainty, and inverse planning constraints in our procedure reduced uncertainty in planning and treatment

  18. Image-robot coupling for the prostate brachytherapy

    International Nuclear Information System (INIS)

    Coelen, V.; Lartigau, E.; Merzouki, R.

    2009-01-01

    The results allows to contemplate a robot use in the prostate brachytherapy but equally in other applications such prostate biopsy. The tests to come are going to be directed towards on the use of a prostate phantom in order to calibrate the ultrasonography. thereafter, we contemplate the conception of an intelligent gripping system placed on the robot arm and allowing a good control in closed loop of the brachytherapy needle placement and allowing the setting up of an online monitoring. (N.C.)

  19. Utilization of prostate brachytherapy for low risk prostate cancer: Is the decline overstated?

    OpenAIRE

    Joseph Safdieh; Andrew Wong; Joseph P. Weiner; David Schwartz; David Schreiber

    2016-01-01

    Purpose : Several prior studies have suggested that brachytherapy utilization has markedly decreased, coinciding with the recent increased utilization of intensity modulated radiation therapy, as well as an increase in urologist-owned centers. We sought to investigate the brachytherapy utilization in a large, hospital-based registry. Material and methods: Men with prostate cancer diagnosed between 2004-2012 and treated with either external beam radiation and/or prostate brachytherapy ...

  20. Posttreatment biopsy results following interstitial brachytherapy in early-stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Hoak, David C.; Grimm, Peter D.; Ragde, Haakon; Cavanagh, William; Blasko, John C.

    1997-01-01

    Purpose: To assess pathologic control rates for prostatic carcinoma as determined by postimplant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound-directed, transperineal, computer generated, volume technique. Methods and Materials: Four hundred and two patients received permanent 125 I or 103 Pd interstitial brachytherapy as primary treatment for early stage prostatic carcinoma at the Northwest Tumor Institute between January 1988 and January 1994. Of these, 201 have consented to biopsy 12 or more months postimplant with a median follow-up of 40 months (range: 12-83 months). None had received homonal manipulation. A total of 361 biopsies was performed on 201 patients with a range of one to six annual biopsies per patient (91 received multiple, serial biopsies). Of the 161 patients more than 12 months postimplant who have not been biopsied, most have been unwilling or unable to submit to biopsy. Only six patients with biochemical progression have not been biopsied. There was no difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. One hundred and forty-three received 125 I (71%) prescribed to a MPD of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received 103 Pd prescribed to a MPD of 115 Gy with a median activity of 123 mCi. Multiple biopsies were performed under transrectal ultrasound guidance, and all specimens were classified as either negative, indeterminate, or positive. Results: At the time of last biopsy, 161 (80%) have achieved negative pathology, 34 (17%) remain indeterminate, and 6 (3%) have been positive. Only 2 of the 186 patients with a PSA < 4.0 ng/ml at the time of biopsy were positive. Among those 33 indeterminate patients with a subsequent biopsy, 28 have converted to negative, 2 to positive, and 3 remain unchanged to date. Conclusions: These data demonstrate at

  1. Prostate specific antigen bounce is related to overall survival in prostate brachytherapy.

    Science.gov (United States)

    Hinnen, Karel A; Monninkhof, Evelyn M; Battermann, Jan J; van Roermund, Joep G H; Frank, Steven J; van Vulpen, Marco

    2012-02-01

    To investigate the association between prostate specific antigen (PSA) bounce and disease outcome after prostate brachytherapy. We analyzed 975 patients treated with (125)I implantation monotherapy between 1992 and 2006. All patients had tumor Stage ≤ 2c, Gleason score ≤ 7 prostate cancer, a minimum follow-up of 2 years with at least four PSA measurements, and no biochemical failure in the first 2 years. Median follow-up was 6 years. Bounce was defined as a PSA elevation of +0.2 ng/mL with subsequent decrease to previous nadir. We used the Phoenix +2 ng/mL definition for biochemical failure. Additional endpoints were disease-specific and overall survival. Multivariate Cox regression analysis was performed to adjust for potential confounding factors. Bounce occurred in 32% of patients, with a median time to bounce of 1.6 years. More than 90% of bounces took place in the first 3 years after treatment and had disappeared within 2 years of onset. Ten-year freedom from biochemical failure, disease-specific survival, and overall survival rates were, respectively, 90%, 99%, and 88% for the bounce group and 70%, 93%, and 82% for the no-bounce group. Only 1 patient (0.3%) died of prostate cancer in the bounce group, compared with 40 patients (6.1%) in the no-bounce group. Adjusted for confounding, a 70% biochemical failure risk reduction was observed for patients experiencing a bounce (hazard ratio 0.31; 95% confidence interval 0.20-0.48). A PSA bounce after prostate brachytherapy is strongly related to better outcome in terms of biochemical failure, disease-specific survival, and overall survival. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Utilization of prostate brachytherapy for low risk prostate cancer: Is the decline overstated?

    Science.gov (United States)

    Safdieh, Joseph; Wong, Andrew; Weiner, Joseph P; Schwartz, David; Schreiber, David

    2016-08-01

    Several prior studies have suggested that brachytherapy utilization has markedly decreased, coinciding with the recent increased utilization of intensity modulated radiation therapy, as well as an increase in urologist-owned centers. We sought to investigate the brachytherapy utilization in a large, hospital-based registry. Men with prostate cancer diagnosed between 2004-2012 and treated with either external beam radiation and/or prostate brachytherapy were abstracted from the National Cancer Database. In order to be included, men had to be clinically staged as T1c-T2aNx-0Mx-0, Gleason 6, PSA ≤ 10.0 ng/ml. Descriptive statistics were used to analyze brachytherapy utilization over time and were compared via χ(2). Multivariate logistic regression was used to assess for covariables associated with increased brachytherapy usage. There were 89,413 men included in this study, of which 37,054 (41.6%) received only external beam radiation, and 52,089 (58.4%) received prostate brachytherapy. The use of brachytherapy declined over time from 62.9% in 2004 to 51.3% in 2012 (p facilities (60.8% in 2004 to 47.0% in 2012, p facilities (63.7% in 2004 to 53.0% in 2012, p facilities than those who lived further. The use of intensity modulated radiation therapy increased during this same time period from 18.4% in 2004 to 38.2% in 2012 (p usage. In this hospital-based registry, prostate brachytherapy usage has declined for low risk prostate cancer as intensity modulated radiation therapy usage has increased. However, it still remains the treatment of choice for 51.3% of patients as of 2012.

  3. A comparison of radiation dose to the neurovascular bundles in men with and without prostate brachytherapy-induced erectile dysfunction

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Dorsey, Anthony T.; Lief, Jonathan H.; Donzella, Joseph G.

    2000-01-01

    Purpose: The etiology of erectile dysfunction after definitive local therapy for carcinoma of the prostate gland represents a multifactorial phenomenon including neurogenic compromise, venous insufficiency, local trauma, and psychogenic causes. It has been suggested that impotence after prostate brachytherapy is a consequence of excessive radiation dose to the neurovascular bundles (NVB). Herein we evaluate the potential relationship between radiation dose to the NVB and the development of erectile dysfunction following prostate brachytherapy. Methods and Materials: The radiation dose to the NVB was evaluated for 33 patients who developed erectile dysfunction (ED) following brachytherapy plus 21 additional patients who were potent before and subsequent to brachytherapy. Of the 54 patient study group, the median follow up was 37 months, and 25 patients were managed with 125 I as a monotherapeutic approach and 29 received 103 Pd as a boost following 45 Gy of external beam radiation therapy. Radiographic localization of the NVB was performed via a two-dimensional geometric model that placed 3-NVB calculation points on the left and right posterolateral side of each 5-mm CT slice. Parameters evaluated included dose-surface histograms, dose parameters via point doses on each slice, the magnitude of the dose in relationship to the distance from the base, and the relationship between NVB radiation dose in patients with and without ED, patient response to sildenafil and case sequence number. Results: In terms of percent prescribed minimum peripheral dose (% mPD), there was no significant difference in mean neurovascular bundle dose between potent and impotent patients, between the isotopes ( 125 I or 103 Pd), mono- or boost therapy, or side of the prostate for which the overall average was 217% ± 55% of mPD. There was also no significant dosimetric difference in terms of response to sildenafil based on a multivariate analysis which included % mPD and various dose

  4. Radiotherapy and brachytherapy

    International Nuclear Information System (INIS)

    2007-02-01

    This presentation first defines the radiotherapy and brachytherapy techniques, indicates the used ionizing radiations (electromagnetic and particles), describes the mechanisms and processes of action of ionizing radiations: they can be physical by photon-matter interactions (Compton effect and photoelectric effect) or due to electron-matter interactions (excitation, ionization), physical-chemical by direct or indirect action (DNA damage), cellular (mitotic or apoptotic death), tissue (sane and tumorous tissues and differential effect). It discusses the biological efficiency of these treatments which depends on different parameters: intrinsic radio-sensitivity, time (session fractioning and organisation in time), oxygen, radiation quality, cellular cycle, dose rate, temperature. It presents the different types of radiotherapy: external radiotherapy (general sequence, delineation, dosimetry, protection of critical organs, treatment session, quality control, monitoring consultation) and briefly presents some specific techniques (total body irradiation, total cutaneous electron therapy, pre-operation radiotherapy, radio-surgery, hadron-therapy). It proposes an overview of the main indications for this treatment: brain tumours, upper aero digestive tract tumours, bronchial tumours, oesophagus, stomach and pancreas tumours, breast tumours, cervix cancer, rectum tumour, and so on, and indicates the possible associated treatments. The next part addresses brachytherapy. It presents the principles and comments the differences with radiotherapy. It indicates the used radio-elements (Caesium 137, Iridium 192, Iodine 125), describes the implementation techniques (plastic tubes, use of iodine 125, intracavitary and endo-luminal radiation therapy). It proposes an overview of the different treated tumours (skin, breast, prostates, bronchial, oesophagus, ENT) and indicates possible early and late secondary effects for different organs

  5. The influence of isotope and prostate volume on urinary morbidity after prostate brachytherapy

    International Nuclear Information System (INIS)

    Niehaus, Angela; Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Allen, Zachariah A.; Galbreath, Robert W.; Adamovich, Edward

    2006-01-01

    Purpose: To evaluate the influence of isotope and prostate size on International Prostate Symptom Score (IPSS) normalization, catheter dependency, and the need for surgical intervention secondary to bladder outlet obstruction after prostate brachytherapy. Methods and Materials: Between January 1998 and June 2003, 976 consecutive patients underwent brachytherapy for clinical stage T1b-T3a (2002 American Joint Committee on Cancer) prostate cancer. Seven hundred eighty-nine (80.8%) were implanted with 103 Pd and 187 (19.2%) with 125 I. The median follow-up was 41.2 months. Patients were stratified into size cohorts ≤25 cm 3 , 25.1-35 cm 3 , 35.1-45 cm 3 , and >45 cm 3 . Four hundred eighteen patients (42.8%) received androgen deprivation therapy (ADT). Four hundred eighty-six patients (49.7%) received supplemental external-beam radiation therapy (XRT). In all patients, an alpha blocker was initiated before implantation and continued at least until the IPSS returned to baseline. IPSS resolution was defined as a return to within one point of baseline. The median number of IPSS determinations per patient was 21. Clinical, treatment, and dosimetric parameters evaluated included patient age, pretreatment PSA, Gleason score, clinical T stage, percent positive biopsies, preimplant IPSS, ultrasound volume, planning volume, isotope, V 100/150/20 , D 9 , urethral dose (average and maximum), supplemental XRT, ADT, and the duration of ADT (≤6 months vs. >6 months). Catheter dependency and the need for postsurgical intervention were also evaluated. Results: For both isotopes and all prostate size cohorts, IPSS peaked 1 month after implantation and returned to baseline at a mean of 1.9 months. Stratification of prostate size cohorts by isotope demonstrated no significant differences in prolonged catheter dependency (≥5 days), IPSS resolution, or postimplant surgical intervention. In Cox regression analysis, IPSS normalization was best predicted by preimplant IPSS, XRT, and

  6. Preoperative irradiation, lymphadenectomy, and 125iodine implantation for patients with localized carcinoma of the prostate

    International Nuclear Information System (INIS)

    DeLaney, T.F.; Shipley, W.U.; O'Leary, M.P.; Biggs, P.J.; Prout, G.R. Jr.

    1986-01-01

    Fifty-four patients with clinically and surgically localized prostatic carcinoma were treated with low-dose preoperative irradiation (1050 cGy), pelvic lymphadenectomy, and interstitial 125 Iodine implantation. The follow-up range is 2 to 9 years with a median follow-up of 5 years. Overall local tumor control is 92%. Actuarial 5-year survival is 86% and the actuarial disease-free survival at 5 years is 73%. Patients with poorly differentiated tumors have a significantly worse actuarial survival (62%) at 5 years than patients with well (95%) or moderately well differentiated tumors (93%), p = 0.04. Disease-free survival at 5 years was influenced by grade: well (100%), moderate (60%), and poor (48%), p = 0.03. Multivariate regression analysis indicates that only the degree of differentiation (p = 0.05) significantly impacts on survival. Both degree of differentiation (p = 0.04) and nodal status (p = 0.03) significantly influence disease-free survival. Potency has been maintained in 71% of patients potent at the time of implantation. Late reactions have been acceptable to date: bladder outlet obstruction (13%), mild proctitis (13%), cystourethritis (6%), incontinence (2%), and prostatic calculi (2%)

  7. Recovery of iodine as iodine-125 from biological materials prior to assay

    International Nuclear Information System (INIS)

    Jones, G.B.; Belling, G.B.; Buckley, R.A.

    1979-01-01

    In biological tissues iodine is usually present as iodoamino acids or iodoproteins. The organic material must be oxidised and the iodine converted into iodate prior to the final spectrophotometric determination. At parts per billion (10 9 ) levels, recoveries of added iodine are difficult to measure precisely as iodine can easily be lost from the sample and added inorganic iodine may not be recovered in the same proportions as the naturally occurring iodine. Iodine-125 provides a much more sensitive, specific and accurate means of testing the recovery of nanogram amounts of iodine from biological tissues and it can be incorporated into tissues in the naturally occurring compounds. Plants can be grown in a solution culture containing iodine-125 and animals can be injected with iodine-125 to provide tissues where naturally occurring iodine compounds are labelled with radioactive iodine. These tissues can be used to examine the recovery of iodine after oven drying, freeze drying, alkali ashing and acid digestion of the samples. Experimental details are given for spinach, tobacco, oats, cauliflower and thyroid. Results are given and discussed. (author)

  8. Iodine-125 orbital brachytherapy with a prosthetic implant in situ

    Energy Technology Data Exchange (ETDEWEB)

    Stannard, Clare [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Radiation Oncology; Maree, Gert; Munro, Roger [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Medical Physics; Lecuona, Karin [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Ophthalmology; Sauerwein, Wolfgang [Universitaetsklinikum Essen (Germany). Strahlenklinik, NCTeam

    2011-05-15

    Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. Patients and Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant. (orig.)

  9. Criteria for safe working with iodine-125

    International Nuclear Information System (INIS)

    Linsley, G.S.

    1977-01-01

    Radio-immunoassay and other saturation assay tests involving the use of iodine-125 are finding wide application for the determination of hormone concentrations in biological fluids. In such tests, iodinations involving concentrations of a milli-curie per micro-litre are common. Iodine-125 presents a problem from the monitoring standpoint because of its low energy photon emission (27 and 35 keV). Iodine is preferentially taken up by the thyroid gland and work involving moderate amounts of radio-iodine may give rise to a significant hazard in an accident situation. The general precautions which should be taken in work with unsealed radioactive substances are briefly summarized, working limits for iodine-125 are identified, and methods of personal protection and monitoring in an emergency situation described. (author)

  10. {sup 125}I brachytherapy in younger prostate cancer patients. Outcomes in low- and intermediate-risk disease

    Energy Technology Data Exchange (ETDEWEB)

    Kindts, Isabelle; Stellamans, Karin; Lambrecht, Antoon [AZ Groeninge Hospital, Department of Radiation Oncology, Kortrijk (Belgium); Billiet, Ignace [AZ Groeninge Hospital, Department of Urology, Kortrijk (Belgium); Pottel, Hans [Catholic University Leuven Kulak, Biostatistics, Faculty of Medicine, Kortrijk (Belgium)

    2017-09-15

    To evaluate local recurrence in younger men treated with low-dose-rate (LDR) {sup 125}I brachytherapy (BT) for localized prostate cancer. A total of 192 patients (≤65-years-old) were treated with LDR {sup 125}I-BT ± hormone therapy. Local failure was defined as any prostate-specific antigen (PSA) rise leading to salvage treatment or biochemical failure according to the Phoenix definition. A bounce was defined as a rise in the nadir of ≥0.2 ng/mL followed by spontaneous return. Proportions were compared using Fisher's exact tests; continuous variables using the unpaired t-test or its non-parametric equivalent. Cox proportional hazards models were applied for multivariable survival analysis. Median follow-up was 66 months. The 5-year local recurrence-free survival was 96.1%. Biopsy-proven local recurrence developed in 13 patients, 4 had a Phoenix-defined recurrence at the last follow-up. Androgen deprivation therapy was started in 1 patient without proven recurrence. Univariable risk factors for local recurrence were: at least 50% positive biopsies, intermediate risk, treatment with neoadjuvant hormone therapy, low preimplantation volume receiving 100% of the prescribed dose, and no bounce development. Hormone-naive patients not attaining a PSA value <0.5 ng/mL during follow-up also had a higher risk of local recurrences. Cox regression demonstrated that the variables ''at least 50% positive biopsies'' and ''bounce'' significantly impacted local failure (hazard ratio, HR 1.02 and 11.59, respectively). A bounce developed in 70 patients (36%). Younger patients and those treated with a lower activity per volume had a higher chance of developing a bounce in the Cox model (HR 0.99 and 0.04, respectively). For younger men, LDR BT is a valid primary curative treatment option in low-risk and is to consider in intermediate-risk localized prostate cancer. (orig.) [German] Bestimmung der Lokalrezidivrate bei juengeren Patienten

  11. Influence of modifications in the positioning of phantoms in the Monte Carlo computational simulation of the prostate brachytherapy; Influencia de alteracoes no posicionamento de fantomas nas simulacoes computacionais Monte Carlo de braquiterapia de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson, E-mail: konrado.radiologia@gmail.co, E-mail: jose.wilson59@uol.com.b [Instituto Federal de Educacao, Ciencia e Tecnologia (IFPE), Recife, PE (Brazil); Costa, Kleber Souza Silva [Faculdade Integrada de Pernambuco (FACIPE), Recife, PE (Brazil); Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-07-01

    Radiotherapy simulation procedures using Monte Carlo methods have shown to be increasingly important to the improvement of cancer fighting strategies. Within this context, brachytherapy is one of the most used methods to ensure better life quality when compared to other therapeutic modalities. These procedures are planned with the use of sectional exams with the patient in lying position. However, it is known that alteration of body posture after the procedure has an influence in the localization of many organs. This study had the aim to identify and to measure the influence of such alterations in MC brachytherapy simulations. In order to do so, prostate brachytherapy with the use of Iodine-125 radionuclide was chosen as model. Simulations were carried out with 108 events using EGSnrc code associated to MASH phantom in orthostatic and supine positions. Significant alterations were found, especially regarding bladder, small intestine and testicles. (author)

  12. Procedure for determination of the decontamination of piping in the production of iodine-125 seeds

    International Nuclear Information System (INIS)

    Moura, J.A.; Moura, E.S.; Sprenger, F.E.; Nagatomi, H.R.; Zeituni, C.A.; Feher, A.; Manzoli, J.E.; Souza, C.D.; Rostelato, M.E.C.M.

    2009-01-01

    Iodine-125 seeds are radioactive sources used in the prostate cancer treatment. This work objective was to determine the necessary conditions and procedures for decontamination of liquid transfer tubes when a radioactive material leakage occurs during the process of seed quality control

  13. Iodine uptake and prostate cancer in the TRAMP mouse model.

    Science.gov (United States)

    Olvera-Caltzontzin, Paloma; Delgado, Guadalupe; Aceves, Carmen; Anguiano, Brenda

    2013-11-08

    Iodine supplementation exerts antitumor effects in several types of cancer. Iodide (I⁻) and iodine (I₂) reduce cell proliferation and induce apoptosis in human prostate cancer cells (LNCaP and DU-145). Both chemical species decrease tumor growth in athymic mice xenografted with DU-145 cells. The aim of this study was to analyze the uptake and effects of iodine in a preclinical model of prostate cancer (transgenic adenocarcinoma of the mouse prostate [TRAMP] mice/SV40-TAG antigens), which develops cancer by 12 wks of age. ¹²⁵I⁻ and ¹²⁵I₂ uptake was analyzed in prostates from wild-type and TRAMP mice of 12 and 24 wks in the presence of perchlorate (inhibitor of the Na⁺/I⁻ symporter [NIS]). NIS expression was quantified by quantitative polymerase chain reaction (qPCR). Mice (6 wks old) were supplemented with 0.125 mg I⁻ plus 0.062 mg I₂/mouse/day for 12 or 24 wks. The weight of the genitourinary tract (GUT), the number of acini with lesions, cell proliferation (levels of proliferating cell nuclear antigen [PCNA] by immunohistochemistry), p53 and p21 expression (by qPCR) and apoptosis (relative amount of nucleosomes by enzyme-linked immunosorbent assay) were evaluated. In both age-groups, normal and tumoral prostates take up both forms of iodine, but only I⁻ uptake was blocked by perchlorate. Iodine supplementation prevented the overexpression of NIS in the TRAMP mice, but had no effect on the GUT weight, cell phenotype, proliferation or apoptosis. In TRAMP mice, iodine increased p53 expression but had no effect on p21 (a p53-dependent gene). Our data corroborate NIS involvement in I⁻ uptake and support the notion that another transporter mediates I₂ uptake. Iodine did not prevent cancer progression. This result could be explained by a strong inactivation of the p53 pathway by TAG antigens.

  14. American Brachytherapy Society recommendations for reporting morbidity after prostate brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Ellis, Rodney J.; Merrick, Gregory S.; Bahnson, Robert; Wallner, Kent; Stock, Richard

    2002-01-01

    Purpose: To standardize the reporting of brachytherapy-related prostate morbidity to guide ongoing clinical practice and future investigations. Methods: Members of the American Brachytherapy Society (ABS) with expertise in prostate brachytherapy performed a literature review and, guided by their clinical experience, formulated specific recommendations for reporting on morbidity related to prostate brachytherapy. Results: The ABS recommends using validated, patient-administered health-related quality-of-life instruments for the determination of baseline and follow-up data regarding bowel, urinary, and sexual function. Both actuarial and crude incidences should be reported, along with the temporal resolution of specific complications, and correlated with the doses to the normal tissues. The International Prostate Symptom Score is recommended to assess urinary morbidity, and any dysuria, gross hematuria, urinary retention, incontinence, or medication use should be quantified. Likewise, the ''Sexual Health Inventory for Men,'' which includes the specific erectile questions of the International Index of Erectile Function, is the preferred instrument for reporting sexual function, and the loss of sexual desire, incidence of hematospermia, painful orgasm (orgasmalgia), altered orgasm intensity, decreased ejaculatory volume, use of erectile aids, and use of hormones for androgen deprivation should be quantified. The ABS recommends adoption of the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer acute and late radiation morbidity scoring scheme for reporting rectal morbidity and noting the incidence of rectal steroid, laser, or antidiarrheal use. Conclusion: It is important to focus on health-related quality-of-life issues in the treatment of prostate cancer, because the control rates are very similar between appropriate treatment modalities. The ABS recommends using the International Prostate Symptom Score, International Index of

  15. Utilization of prostate brachytherapy for low risk prostate cancer: Is the decline overstated?

    Directory of Open Access Journals (Sweden)

    Joseph Safdieh

    2016-08-01

    Full Text Available Purpose : Several prior studies have suggested that brachytherapy utilization has markedly decreased, coinciding with the recent increased utilization of intensity modulated radiation therapy, as well as an increase in urologist-owned centers. We sought to investigate the brachytherapy utilization in a large, hospital-based registry. Material and methods: Men with prostate cancer diagnosed between 2004-2012 and treated with either external beam radiation and/or prostate brachytherapy were abstracted from the National Cancer Database. In order to be included, men had to be clinically staged as T1c-T2aNx-0Mx-0, Gleason 6, PSA ≤ 10.0 ng/ml. Descriptive statistics were used to analyze brachytherapy utilization over time and were compared via χ2. Multivariate logistic regression was used to assess for covariables associated with increased brachytherapy usage. Results : There were 89,413 men included in this study, of which 37,054 (41.6% received only external beam radiation, and 52,089 (58.4% received prostate brachytherapy. The use of brachytherapy declined over time from 62.9% in 2004 to 51.3% in 2012 (p < 0.001. This decline was noted in both academic facilities (60.8% in 2004 to 47.0% in 2012, p < 0.001 as well as in non-academic facilities (63.7% in 2004 to 53.0% in 2012, p < 0.001. The decline was more pronounced in patients who lived closer to treatment facilities than those who lived further. The use of intensity modulated radiation therapy increased during this same time period from 18.4% in 2004 to 38.2% in 2012 (p < 0.001. On multivariate analysis, treatment at an academic center, increasing age, decreasing distance from the treatment center, and years of diagnosis from 2006-2012 were significantly associated with reduced brachytherapy usage. Conclusions : In this hospital-based registry, prostate brachytherapy usage has declined for low risk prostate cancer as intensity modulated radiation therapy usage has increased. However, it still

  16. Rectal and urinary morbidity in patients undergoing prostate I-125 implant

    International Nuclear Information System (INIS)

    Hu, Kenneth; Wallner, Kent

    1997-01-01

    PURPOSE: To determine the risk of urinary incontinence or severe rectal complications in patients who have TURP/TUIP or rectal bleeding after I-125 prostate brachytherapy. MATERIAL AND METHODS: One hundred nine patients with T1-T2 prostatic carcinoma were treated with I-125 implantation from 1988 through 1994. Ten patients underwent TURP/TUIP after brachtherapy to relieve urinary obstruction refractory to non-surgical management. Twenty-two developed rectal morbidity and were subsequently followed with endoscopy and serial clinical evaluation. RESULTS: Permanent urinary incontinence following TURP/TUIP developed in seven of 10 patients. Urinary incontinence was mild in three patients (LENT score = 1) and severe in 4 additional patients (LENT score = 3). There was no relationship between the degree of incontinence and the use of TURP versus TUIP, mass of tissue resected, or time between brachytherapy and TURP/TUIP. Urethral doses were higher than we generally recommend (> 140 Gy) in the 5 patients for whom detailed urethral radiation dose information was available, Rectal morbidity developed in twenty-two patients. Twenty experienced radiation proctitis-related bright red blood per rectum (BRBPR), the majority of which ((15(20))) were mild (RTOG score = 1) and treated with medical management. The other 5 developed either a rectal ulcer ((3(5))) or fistula ((2(5))). The two patients without significant BRBPR developed a fistula and ulcer. Two of three patients with fistulas had predisposing conditions (pre-implant history of fistula and previous pelvic radiation for rectal cancer). All four rectal ulcers healed with conservative management. CONCLUSION: Permanent urinary incontinence is common in patients who require a TURP/TUIP after prostate brachytherapy. Its cause is multifactorial and may include surgically-related damage to the urinary sphincters and radiation dose to the uretha. Rectal morbidity after prostate brachtherapy is mild in the majority of cases and

  17. Fifteen-Year Biochemical Relapse-Free Survival, Cause-Specific Survival, and Overall Survival Following I125 Prostate Brachytherapy in Clinically Localized Prostate Cancer: Seattle Experience

    International Nuclear Information System (INIS)

    Sylvester, John E.; Grimm, Peter D.; Wong, Jason; Galbreath, Robert W.; Merrick, Gregory; Blasko, John C.

    2011-01-01

    Purpose: To report 15-year biochemical relapse-free survival (BRFS), cause-specific survival (CSS), and overall survival (OS) outcomes of patients treated with I 125 brachytherapy monotherapy for clinically localized prostate cancer early in the Seattle experience. Methods and Materials: Two hundred fifteen patients with clinically localized prostate cancer were consecutively treated from 1988 to 1992 with I 125 monotherapy. They were prospectively followed as a tight cohort. They were evaluated for BRFS, CSS, and OS. Multivariate analysis was used to evaluate outcomes by pretreatment clinical prognostic factors. BRFS was analyzed by the Phoenix (nadir + 2 ng/mL) definition. CSS and OS were evaluated by chart review, death certificates, and referring physician follow-up notes. Gleason scoring was performed by general pathologists at a community hospital in Seattle. Time to biochemical failure (BF) was calculated and compared by Kaplan-Meier plots. Results: Fifteen-year BRFS for the entire cohort was 80.4%. BRFS by D'Amico risk group classification cohort analysis was 85.9%, 79.9%, and 62.2% for low, intermediate, and high-risk patients, respectively. Follow-up ranged from 3.6 to 18.4 years; median follow-up was 15.4 years for biochemically free of disease patients. Overall median follow-up was 11.7 years. The median time to BF in those who failed was 5.1 years. CSS was 84%. OS was 37.1%. Average age at time of treatment was 70 years. There was no significant difference in BRFS between low and intermediate risk groups. Conclusion: I 125 monotherapy results in excellent 15-year BRFS and CSS, especially when taking into account the era of treatment effect.

  18. Study and development of methodology for radioactive iodine fixation in polymeric substrate for manufacturing sources used in brachytherapy; Estudo e desenvolvimento de metodologia para fixacao de iodo radioativo em substrato polimerico para confeccao de fontes utilizadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Bruna T.; Souza, Carla D.; Benega, Marcos A.G. and others, E-mail: bteigarodrigues@gmail.com, E-mail: carladdsouza@yahoo.com.br, E-mail: marcosagbenega@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes

    2014-07-01

    According global estimates of Globocan 2012 project of the International Agency for Research of Cancer, of the World Health Organization, there were 14,1 million new cases of cancer and a total of 8,2 million deaths from cancer. Also show that in 2030, the overall load will be 21,4 million new cases and 13,2 million cancer deaths. One of the prostate cancer therapy is brachytherapy, used in early and middle stages of the disease. It is made with the introduction of seeds with radioactive material within the tumor or in nearby regions, affecting the minimum surrounding tissues. The aim of this work is the study and developing the deposition of radioactive iodine on the polymeric substrate method, and an analysis relating the efficiency of the method to implementation in the laboratory of brachytherapy from IPEN. Iodine-125 is adsorbed on an epoxy resin solution. The objective of this study is to offer a new proposal for seeds. The results will give the data for the radiation protection and the procedures for radioactive waste management.

  19. Late Urinary Side Effects 10 Years After Low-Dose-Rate Prostate Brachytherapy: Population-Based Results From a Multiphysician Practice Treating With a Standardized Protocol and Uniform Dosimetric Goals

    International Nuclear Information System (INIS)

    Keyes, Mira; Miller, Stacy; Pickles, Tom; Halperin, Ross; Kwan, Winkle; Lapointe, Vincent; McKenzie, Michael; Spadinger, Ingrid; Pai, Howard; Chan, Elisa K.; Morris, W. James

    2014-01-01

    Purpose: To determine late urinary toxicity (>12 months) in a large cohort of uniformly treated low-dose-rate prostate brachytherapy patients. Methods and Materials: From 1998 to 2009, 2709 patients with National Comprehensive Cancer Network–defined low-risk and low-tier intermediate-risk prostate cancer were treated with Iodine 125 ( 125 I) low-dose-rate prostate brachytherapy; 2011 patients with a minimum of 25 months of follow-up were included in the study. Baseline patients, treatment, implant factors, and late urinary toxicity (Radiation Therapy Oncology Group [RTOG] grading system and International Prostate Symptom Score [IPSS]) were recorded prospectively. Time to IPSS resolution, late RTOG genitourinary toxicity was examined with Kaplan-Meier and log-rank tests. Cox proportional hazards regression was done for individual covariates and multivariable models. Results: Median follow-up was 54.5 months (range, 2-13 years). Actuarial toxicity rates reached 27% and 10% (RTOG ≥2 and ≥3, respectively) at 9-13 years. Symptoms resolved quickly in the majority of patients (88% in 6-12 months). The prevalence of RTOG 0, 1, 2, 3, and 4 toxicity with a minimum of 7 years' follow-up was 70%, 21%, 6.4%, 2.3%, and 0.08%, respectively. Patients with a larger prostate volume, higher baseline IPSS, higher D90, acute toxicity, and age >70 years had more late RTOG ≥2 toxicity (all P≤.02). The IPSS resolved slower in patients with lower baseline IPSS and larger ultrasound prostate volume, those not receiving androgen deprivation therapy, and those with higher D90. The crude rate of RTOG 3 toxicity was 6%. Overall the rate of transurethral resection of the prostate was 1.9%; strictures, 2%; incontinence, 1.3%; severe symptoms, 1.8%; late catheterization, 1.3%; and hematuria, 0.8%. The majority (80%) resolved their symptoms in 6-12 months. Conclusion: Long-term urinary toxicity after brachytherapy is low. Although actuarial rates increase with longer follow

  20. Late Urinary Side Effects 10 Years After Low-Dose-Rate Prostate Brachytherapy: Population-Based Results From a Multiphysician Practice Treating With a Standardized Protocol and Uniform Dosimetric Goals

    Energy Technology Data Exchange (ETDEWEB)

    Keyes, Mira, E-mail: mkeyes@bccancer.bc.ca; Miller, Stacy; Pickles, Tom; Halperin, Ross; Kwan, Winkle; Lapointe, Vincent; McKenzie, Michael; Spadinger, Ingrid; Pai, Howard; Chan, Elisa K.; Morris, W. James

    2014-11-01

    Purpose: To determine late urinary toxicity (>12 months) in a large cohort of uniformly treated low-dose-rate prostate brachytherapy patients. Methods and Materials: From 1998 to 2009, 2709 patients with National Comprehensive Cancer Network–defined low-risk and low-tier intermediate-risk prostate cancer were treated with Iodine 125 ({sup 125}I) low-dose-rate prostate brachytherapy; 2011 patients with a minimum of 25 months of follow-up were included in the study. Baseline patients, treatment, implant factors, and late urinary toxicity (Radiation Therapy Oncology Group [RTOG] grading system and International Prostate Symptom Score [IPSS]) were recorded prospectively. Time to IPSS resolution, late RTOG genitourinary toxicity was examined with Kaplan-Meier and log-rank tests. Cox proportional hazards regression was done for individual covariates and multivariable models. Results: Median follow-up was 54.5 months (range, 2-13 years). Actuarial toxicity rates reached 27% and 10% (RTOG ≥2 and ≥3, respectively) at 9-13 years. Symptoms resolved quickly in the majority of patients (88% in 6-12 months). The prevalence of RTOG 0, 1, 2, 3, and 4 toxicity with a minimum of 7 years' follow-up was 70%, 21%, 6.4%, 2.3%, and 0.08%, respectively. Patients with a larger prostate volume, higher baseline IPSS, higher D90, acute toxicity, and age >70 years had more late RTOG ≥2 toxicity (all P≤.02). The IPSS resolved slower in patients with lower baseline IPSS and larger ultrasound prostate volume, those not receiving androgen deprivation therapy, and those with higher D90. The crude rate of RTOG 3 toxicity was 6%. Overall the rate of transurethral resection of the prostate was 1.9%; strictures, 2%; incontinence, 1.3%; severe symptoms, 1.8%; late catheterization, 1.3%; and hematuria, 0.8%. The majority (80%) resolved their symptoms in 6-12 months. Conclusion: Long-term urinary toxicity after brachytherapy is low. Although actuarial rates increase with longer

  1. Prognostic Importance of Small Prostate Size in Men Receiving Definitive Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Taira, Al V.; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Adamovich, Edward; Wallner, Kent E.

    2012-01-01

    Purpose: To assess whether small prostate size is an adverse prognostic factor in men undergoing brachytherapy in the same manner in which it seems to be for men undergoing radical prostatectomy. Methods and Materials: From April 1995 to June 2008, 2024 patients underwent brachytherapy by a single brachytherapist. Median follow-up was 7.4 years. The role of small prostate size (≤20 cm 3 ) as a prognostic factor for biochemical progression-free survival, cause-specific survival, and all-cause mortality was investigated. The differences in survival between men with small and larger prostates were compared using Kaplan-Meier curves and log-rank tests. Results: Median prostate size for the entire cohort was 32.7 cm 3 . For the 167 men with small prostates, median prostate size was 17.4 cm 3 . There was no difference in biochemical progression-free survival (95.2% vs 96.2%, P=.603), cause-specific survival (97.7% vs 98.3%, P=.546), or all-cause mortality (78.0% vs 77.2%, P=.838) at 10 years for men with small prostates compared with men with larger prostates. On univariate and multivariate analysis, small prostate size was not associated with any of the primary outcome measures. Conclusion: Men with small prostates treated with brachytherapy have excellent outcomes and are at no higher risk of treatment failure than men with larger glands. High-quality implants with adequate margins seem sufficient to address the increased adverse risk factors associated with small prostate size.

  2. Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

    International Nuclear Information System (INIS)

    Acher, Peter; Rhode, Kawal; Morris, Stephen; Gaya, Andrew; Miquel, Marc; Popert, Rick; Tham, Ivan; Nichol, Janette; McLeish, Kate; Deehan, Charles; Dasgupta, Prokar; Beaney, Ronald; Keevil, Stephen F.

    2008-01-01

    Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability

  3. Phase I Trial of Gross Total Resection, Permanent Iodine-125 Brachytherapy, and Hyperfractionated Radiotherapy for Newly Diagnosed Glioblastoma Multiforme

    International Nuclear Information System (INIS)

    Chen, Allen M.; Chang, Susan; Pouliot, Jean; Sneed, Penny K.; Prados, Michael D.; Lamborn, Kathleen R.; Malec, Mary K.; McDermott, Michael W.; Berger, Mitchell S.; Larson, David A.

    2007-01-01

    Purpose: To evaluate the feasibility of gross total resection and permanent I-125 brachytherapy followed by hyperfractionated radiotherapy for patients with newly diagnosed glioblastoma. Methods and Materials: From April 1999 to May 2002, 21 patients with glioblastoma multiforme were enrolled on a Phase I protocol investigating planned gross total resection and immediate placement of permanent I-125 seeds, followed by postoperative hyperfractionated radiotherapy to a dose of 60 Gy at 100 cGy b.i.d., 5 days per week. Median age and Karnofsky performance status were 50 years (range, 32-65 years) and 90 (range, 70-100), respectively. Toxicity was assessed according to Radiation Therapy Oncology Group criteria. Results: Eighteen patients completed treatment according to protocol. The median preoperative tumor volume on magnetic resonance imaging was 18.6 cm 3 (range, 4.4-41.2 cm 3 ). The median brachytherapy dose measured 5 mm radially outward from the resection cavity was 400 Gy (range, 200-600 Gy). Ten patients underwent 12 reoperations, with 11 of 12 reoperations demonstrating necrosis without evidence of tumor. Because of high toxicity, the study was terminated early. Median progression-free survival and overall survival were 57 and 114 weeks, respectively, but not significantly improved compared with historical patients treated at University of California, San Francisco, with gross total resection and radiotherapy without brachytherapy. Conclusions: Treatment with gross total resection and permanent I-125 brachytherapy followed by hyperfractionated radiotherapy as performed in this study results in high toxicity and reoperation rates, without demonstrated improvement in survival

  4. Prostate Brachytherapy With Oblique Needles to Treat Large Glands and Overcome Pubic Arch Interference

    International Nuclear Information System (INIS)

    Ryu, Bon; Bax, Jeff; Edirisinge, Chandima; Lewis, Craig; Chen, Jeff; D’Souza, David; Fenster, Aaron; Wong, Eugene

    2012-01-01

    Purpose: First, to show that low-dose-rate prostate brachytherapy plans using oblique needle trajectories are more successful than parallel trajectories for large prostates with pubic arch interference (PAI); second, to test the accuracy of delivering an oblique plan by using a three-dimensional (3D) transrectal ultrasonography (TRUS)-guided mechatronic system. Methods and Materials: Prostates were contoured for 5 subjects’ 3D TRUS images showing a maximum PAI of ≤1 cm and a prostate volume of <50 cc. Two planning studies were done. First, prostate contours were artificially enlarged to 45 to 80 cc in 5- to 10-cc increments for a single subject. Second, all subject prostate contours were enlarged to 60 cc. For each study, three types of plans were manually created for comparison: a parallel needle template (PT) plan, a parallel needle no-template (PNT) plan, and an oblique needle no-template (OBL) plan. Needle positions and angles were not discretized for nontemplate plans. European Society for Therapeutic Radiology and Oncology dose-volume histogram guidelines, iodine-125 (145-Gy prescription, 0.43 U), and needle angles of <15° were used. An OBL plan was delivered to a pubic arch containing a 60-cc prostate phantom that mimicked the anatomy of the subject with the greatest PAI (23% by volume). Results: In the increasing-prostate volume study, OBL plans were successful for prostates of ≤80 cc, and PT plans were successful for prostates of <65 cc. In paired, one-sided t tests for the 60-cc volume study, OBL plans showed dosimetric improvements for all organs compared to both of the parallel type plans (p < 0.05); PNT plans showed a benefit only in planning target volumes receiving more than 100 Gy compared to PT plans. A computed tomography scan of the phantom showed submillimeter seed placement accuracy in all directions. Conclusion: OBL plans were significantly better than parallel plans, and an OBL plan was accurately delivered to a 60-cc prostate phantom

  5. Thyroid measurements of Iodine-125 workers

    International Nuclear Information System (INIS)

    Burns, P.A.; Peggie, J.R.

    1979-02-01

    The accumulation of 125 I in the thyroid presents real hazards to workers who use this radionuclide. Recent assessments of the maximum permissible thyroid burden for 125 I have tended to be lower than those previously adopted. Workers using 125 I may receive small doses to a film badge monitor from external radiation while accumulating significant doses to the thyroid from internal contamination. It is therefore necessary to perform some form of thyroid monitoring on such workers. In the past two years the Australian Radiation Laboratory has monitored 125 I workers from six different institutations in the Melbourne area to determine the activity of 125 I in their thyroids. Most of the levels monitored were less than one tenth of the most recently recommended thyroid burden of 400 nanocurie. The highest levels were measured in workers who actually perform iodinations. Workers who handle the iodinate generally had lower levels than those performing the iodinations. Only a very small number of the workers measured were below the detectable limit of the system indicating that even when low activities of 125 I are handled in relatively stable forms it is still possible to accumulate 125 I in the thyroid

  6. SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System

    International Nuclear Information System (INIS)

    Joseph, F Maria; Podder, T; Yu, Y

    2015-01-01

    Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostate HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system

  7. Novel prostate brachytherapy technique: Improved dosimetric and clinical outcome

    International Nuclear Information System (INIS)

    Nobes, Jenny P.; Khaksar, Sara J.; Hawkins, Maria A.; Cunningham, Melanie J.; Langley, Stephen E.M.; Laing, Robert W.

    2008-01-01

    Purpose: Erectile dysfunction following prostate brachytherapy is reported to be related to dose received by the penile bulb. To minimise this, whilst preserving prostate dosimetry, we have developed a technique for I-125 seed brachytherapy using both stranded seeds and loose seeds delivered with a Mick applicator, and implanted via the sagittal plane on trans-rectal ultrasound. Materials and methods: Post-implant dosimetry and potency rates were compared in 120 potent patients. In Group 1, 60 patients were treated using a conventional technique of seeds implanted in a modified-uniform distribution. From January 2005, a novel technique was developed using stranded seeds peripherally and centrally distributed loose seeds implanted via a Mick applicator (Group 2). The latter technique allows greater flexibility when implanting the seeds at the apex. Each patient was prescribed a minimum peripheral dose of 145 Gy. No patients received external beam radiotherapy or hormone treatment. There was no significant difference in age or pre-implant potency score (mean IIEF-5 score 22.4 vs. 22.6, p = 0.074) between the two groups. Results: The new technique delivers lower penile bulb doses (D 25 as %mPD - Group 1: 61.2 ± 35.7, Group 2: 29.7 ± 16.0, p 50 as %mPD - Group 1: 45.8 ± 26.9, Group 2: 21.4 ± 11.7, p 90 - Group 1: 147 Gy ± 21.1, Group 2: 155 Gy ± 16.7, p = 0.03). At 2 years, the potency rate was also improved: Group 1: 61.7%; Group 2: 83.3% (p = 0.008). Conclusions: In this study, the novel brachytherapy technique using both peripheral stranded seeds and central loose seeds delivered via a Mick applicator results in a lower penile bulb dose whilst improving prostate dosimetry, and may achieve higher potency rates

  8. Sexual function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Galbreath, R.W.; Merrick, G.S.; Butler, W.M.; Stipetich, R.L.; Abel, L.J.; Lief, J.H.

    2001-01-01

    Purpose: To determine the incidence of potency preservation following permanent prostate brachytherapy and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Materials and Methods: 425 patients underwent permanent prostate brachytherapy from April 1995 to October 1999. 209 patients who were potent prior to brachytherapy and currently not receiving hormonal manipulation were mailed an International Index of Erectile Function (IIEF) questionnaire with a pre-addressed stamped envelope. 180 patients completed and returned the questionnaire. Median patient follow-up was 39 months (range 18-74 months). Pre-implant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Post-implant potency was defined as an IIEF score >11. Clinical parameters evaluated for sexual function included patient age, clinical T stage, elapsed time since implantation, hypertension, diabetes mellitus, and tobacco consumption. Evaluated treatment parameters included the utilization of neoadjuvant hormonal manipulation and the choice of isotope. The efficacy of sildenafil citrate in brachytherapy induced erectile dysfunction (ED) was also evaluated. Results: A pre-treatment erectile function score of 2 and 1 were assigned to 126 and 54 patients respectively. With 6 year follow up, 39% of patients maintained potency following prostate brachytherapy with a plateau on the curve. Post-implant preservation of potency (IIEF>11) correlated with pre-implant erectile function (50% versus 14% for pre-implant scores of 2 and 1 respectively, p≤0.0001), patient age (56%, 38%, and 23% for patients <60 years of age, 60-69 years of age, and ≥70 years of age respectively, p=0.012) and a history of diabetes mellitus

  9. Local radiolytic effectiveness of Auger electrons of iodine-125 in benzene-iodine solutions

    International Nuclear Information System (INIS)

    Uenak, P.; Uenak, T.

    1987-01-01

    High radiotoxicity of iodine-125 has been mainly attributed to the local radiolytic effects of Auger electrons on biological systems. In the present study, experimental and theoretical results are compared. The agreement between the experimental and theoretical results explains that the energy absorption of iodine aggregates has an important role in the radiolytic effectiveness of Auger electrons and iodine-125 in benzene-iodine solutions. (author) 18 refs.; 3 figs

  10. Perioperative Search for Circulating Tumor Cells in Patients Undergoing Prostate Brachytherapy for Clinically Nonmetastatic Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Hideyasu Tsumura

    2017-01-01

    Full Text Available Despite the absence of local prostate cancer recurrence, some patients develop distant metastases after prostate brachytherapy. We evaluate whether prostate brachytherapy procedures have a potential risk for hematogenous spillage of prostate cancer cells. Fifty-nine patients who were undergoing high-dose-rate (HDR or low-dose-rate (LDR brachytherapy participated in this prospective study. Thirty patients with high-risk or locally advanced cancer were treated with HDR brachytherapy after neoadjuvant androgen deprivation therapy (ADT. Twenty-nine patients with clinically localized cancer were treated with LDR brachytherapy without neoadjuvant ADT. Samples of peripheral blood were drawn in the operating room before insertion of needles (preoperative and again immediately after the surgical manipulation (intraoperative. Blood samples of 7.5 mL were analyzed for circulating tumor cells (CTCs using the CellSearch System. While no preoperative samples showed CTCs (0%, they were detected in intraoperative samples in 7 of the 59 patients (11.8%; preoperative vs. intraoperative, p = 0.012. Positive CTC status did not correlate with perioperative variables, including prostate-specific antigen (PSA at diagnosis, use of neoadjuvant ADT, type of brachytherapy, Gleason score, and biopsy positive core rate. We detected CTCs from samples immediately after the surgical manipulation. Further study is needed to evaluate whether those CTCs actually can survive and proliferate at distant sites.

  11. Optical fibre luminescence sensor for real-time LDR brachytherapy dosimetry

    Science.gov (United States)

    Woulfe, P.; O'Keeffe, S.; Sullivan, F. J.

    2018-02-01

    An optical fibre sensor for monitoring low dose radiation is presented. The sensor is based on a scintillation material embedded within the optical fibre core, which emits visible light when exposed to low level ionising radiation. The incident level of ionising radiation can be determined by analysing the optical emission. An optical fibre sensor is developed, based on radioluminescence whereby radiation sensitive scintillation material, terbium doped gadolinium oxysulphide (Gd2O2S:Tb), is embedded in a cavity of 700μm of a 1mm plastic optical fibre. The sensor is designed for in-vivo monitoring of the radiation dose during radio-active seed implantation for low dose rate (LDR) brachytherapy, in prostate cancer treatment, providing radiation oncologists with real-time information of the radiation dose to the target area and/or nearby organs at risk (OARs). The radiation from the brachytherapy seeds causes emission of visible light from the scintillation material through the process of radioluminescence, which penetrates the fibre, propagating along the optical fibre for remote detection using a multi-pixel photon counter. The sensor demonstrates a high sensitivity to 0.397mCi of Iodine125, the radioactive source most commonly used in brachytherapy for treating prostate cancer.

  12. Advantages of high-dose rate (HDR) brachytherapy in treatment of prostate cancer

    Science.gov (United States)

    Molokov, A. A.; Vanina, E. A.; Tseluyko, S. S.

    2017-09-01

    One of the modern methods of preserving organs radiation treatment is brachytherapy. This article analyzes the results of prostate brachytherapy. These studies of the advantages of high dose brachytherapy lead to the conclusion that this method of radiation treatment for prostate cancer has a favorable advantage in comparison with remote sensing methods, and is competitive, preserving organs in comparison to surgical methods of treatment. The use of the method of polyfocal transperineal biopsy during the brachytherapy session provides information on the volumetric spread of prostate cancer and adjust the dosimetry plan taking into account the obtained data.

  13. Effect of post-implant edema on prostate brachytherapy treatment margins

    International Nuclear Information System (INIS)

    Reed, Daniel R.; Wallner, Kent; Ford, Eric; Mueller, Amy; Merrick, Gregory; Maki, Jeffrey; Sutlief, Steven; Butler, Wayne

    2005-01-01

    Purpose: To determine if postimplant prostate brachytherapy treatment margins calculated on Day 0 differ substantially from those calculated on Day 30. Methods: Thirty patients with 1997 American Joint Commission on Cancer clinical stage T1-T2 prostatic carcinoma underwent prostate brachytherapy with I-125 prescribed to 144 Gy. Treatment planning methods included using loose seeds in a modified peripheral loading pattern and treatment margins (TMs) of 5-8 mm. Postimplant plain radiographs, computed tomography scans, and magnetic resonance scans were obtained 1-4 hours after implantation (Day 0). A second set of imaging studies was obtained at 30 days after implantation (Day 30) and similarly analyzed. Treatment margins were measured as the radial distance in millimeters from the prostate edge to the 100% isodose line. The TMs were measured and tabulated at 90 o intervals around the prostate periphery at 0.6-cm intervals. Each direction was averaged to obtain the mean anterior, posterior, left, and right margins. Results: The mean overall TM increased from 2.6 mm (±2.3) on Day 0 to 3.5 mm (±2.4) on Day 30. The mean anterior margin increased from 1.2 mm on Day 0 to 1.8 mm on Day 30. The posterior margin increased from 1.2 mm on Day 0 to 2.8 mm on Day 30. The lateral treatment margins increased most over time, with mean right treatment margin increasing from 3.9 mm on Day 0 to 4.7 mm on Day 30. Conclusion: Treatment margins appear to be durable in the postimplant period, with a clinically insignificant increase from Day 0 to Day 30

  14. Timing of computed tomography-based postimplant assessment following permanent transperineal prostate brachytherapy

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Bice, William S.; Kiefer, Eric J.; Prete, James J.

    1998-01-01

    Purpose: To establish the rate of resolution of prostatic edema following transperineal interstitial permanent prostate brachytherapy, and to determine the results and impact of timing of the postimplant assessment on the dose-volume relationship. Methods and Materials: A series of 19 consecutive patients with early-stage adenocarcinoma of the prostate receiving transperineal interstitial permanent prostate brachytherapy, were enrolled in this study. Twelve received 125 I and seven received 103 Pd. Postoperative assessment included a computed tomographic (CT) scan on postoperative days 1, 8, 30, 90, and 180. On each occasion, CT scans were performed on a GE helical unit at 3-mm abutting slices, 15-cm field of view. Prostate volumes were outlined on CT scans by a single clinician. Following digitization of the volumes and radioactive sources, volumes and dose-volume histograms were calculated. The prostate volume encompassed by the 80% and 100% reference isodose volumes was calculated. Results: Preimplant transrectal ultrasound determined volumes varied from 17.5 to 38.6 cc (median 27.9 cc). Prostate volumes previously defined on 40 randomly selected postimplant CT scans were compared in a blinded fashion to a second CT-derived volume and ranged from -32% to +24%. The Pearson correlation coefficient for prostate CT volume reproducibility was 0.77 (p < 0.03). CT scan-determined volume performed on postoperative day 1 was an average of 41.4% greater than the volume determined by preimplant ultrasound. Significant decreases in average volume were seen during the first month postoperatively. Average volume decreased 14% from day 1 to day 8, 10% from day 8 to day 30, 3% from day 30 to day 90, and 2% thereafter. Coverage of the prostate volume by the 80% isodose volume increased from 85.6% on postoperative day 1 to 92.2% on postoperative day 180. The corresponding increase in the 100% reference dose coverage of the prostate volume ranged from 73.1% to 83.3% between

  15. Evolution of brachytherapy for prostate carcinoma

    International Nuclear Information System (INIS)

    Qin Lan

    2005-01-01

    Brachytherapy is one of the most main management to prostate carcinoma. This method has been rapidly accepted in clinical application since it is a convenient, little-traumatic, and outpatient therapy. With the development of techniques of production of radio-seeds, imaging modality and three-dimensional radiotherapy plan system, brachytherapy has been made a virtually progress in improving curative-effect and reducing damage to surrounding normal tissue. (authors)

  16. Dose to the Bladder Neck Is the Most Important Predictor for Acute and Late Toxicity After Low-Dose-Rate Prostate Brachytherapy: Implications for Establishing New Dose Constraints for Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Hathout, Lara; Folkert, Michael R.; Kollmeier, Marisa A.; Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Cohen, Gil' ad N. [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Zelefsky, Michael J., E-mail: zelefskm@mskcc.org [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States)

    2014-10-01

    Purpose: To identify an anatomic structure predictive for acute (AUT) and late (LUT) urinary toxicity in patients with prostate cancer treated with low-dose-rate brachytherapy (LDR) with or without external beam radiation therapy (EBRT). Methods and Materials: From July 2002 to January 2013, 927 patients with prostate cancer (median age, 66 years) underwent LDR brachytherapy with Iodine 125 (n=753) or Palladium 103 (n=174) as definitive treatment (n=478) and as a boost (n=449) followed by supplemental EBRT (median dose, 50.4 Gy). Structures contoured on the computed tomographic (CT) scan on day 0 after implantation included prostate, urethra, bladder, and the bladder neck, defined as 5 mm around the urethra between the catheter balloon and the prostatic urethra. AUT and LUT were assessed with the Common Terminology Criteria for Adverse Events, version4. Clinical and dosimetric factors associated with AUT and LUT were analyzed with Cox regression and receiver operating characteristic analysis to calculate area under the receiver operator curve (ROC) (AUC). Results: Grade ≥2 AUT and grade ≥2 LUT occurred in 520 patients (56%) and 154 patients (20%), respectively. No grade 4 toxicities were observed. Bladder neck D2cc retained a significant association with AUT (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.03-1.04; P<.0001) and LUT (HR, 1.01; 95% CI, 1.00-1.03; P=.014) on multivariable analysis. In a comparison of bladder neck with the standard dosimetric variables by use of ROC analysis (prostate V100 >90%, D90 >100%, V150 >60%, urethra D20 >130%), bladder neck D2cc >50% was shown to have the strongest prognostic power for AUT (AUC, 0.697; P<.0001) and LUT (AUC, 0.620; P<.001). Conclusions: Bladder neck D2cc >50% was the strongest predictor for grade ≥2 AUT and LUT in patients treated with LDR brachytherapy. These data support inclusion of bladder neck constraints into brachytherapy planning to decrease urinary toxicity.

  17. Evaluation of radiation dose on people adjacent to implant patients during brachytherapy for prostate cancer using {sup 192}Ir

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon; Ko, Seong Jin; Kang, Se Sik; Kim, Chang Soo [Catholic University, Busan (Korea, Republic of)

    2009-10-15

    The incidence of prostate cancer is rapidly increasing due to aging of the population and westernization of dietary habits, etc. As a result, the frequency of prostate cancer has become the fifth highest among all male cancers and the first among urological cancers. Brachytherapy is commonly used for locally progressing prostate cancers. Since the mid 1980s, therapies using radio-isotopes, such as low-invasive {sup 125}I, {sup 103}Pd and {sup 192}Ir, have been widely performed in the U.S. and Europe. However, brachytherapy involves implanting radio-isotopes into the human body which is of concern because it may expose the health care professionals administering the therapy to unnecessary radiation. Accordingly, this study intends to predict the radiation dose that people adjacent to patients implanted with a radio-isotope are exposed to during prostate cancer radiation therapy by using a mathematical anthropomorphic phantom and {sup 192}Ir.

  18. Carcinoma of the prostate treated by pelvic node dissection, iodine-125 seed implant and external irradiation; a study of rectal complications

    Energy Technology Data Exchange (ETDEWEB)

    Abadir, R.; Ross, G. Jr.; Weinstein, S.H. (Missouri Univ., Columbia (USA). Hospital and Clinics)

    1984-09-01

    The University of Missouri-Columbia protocol for localised cancer of the prostate calls for pelvic node dissection, 10 000 cGy at the periphery of the prostate from /sup 125/I and 4000 cGy in 20 fractions to the whole pelvis using supervoltage X-ray therapy. Rectal complications were studied in 104 patients; acute and chronic reactions were defined. During external irradiation 54% did not develop diarrhoea, 43% had mild diarrhoea and 3% had severe diarrhoea. In the chronic stage 77% did not have diarrhoea, 12% had delayed, non-distressing rectal bleeding which did not need specific treatment or needed only simple treatment, 7% had prolonged distressing proctitis and 4% had rectal ulceration or recto-urethral fistula necessitating colostomy. Each of the four patients who had colostomy had an additional aetiological factor (arterial disease, pelvic inflammation, additional radiation, pelvic malignancy or second operation). None of the patients entered in the combined brachytherapy and teletherapy programme, and in whom 0.5 cm space was maintained between the closest seed and the rectal mucosa, developed prolonged proctitis.

  19. Role of brachytherapy in the treatment of localized prostate cancer

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2015-01-01

    Full Text Available The review is devoted to application of brachytherapy for treating the localized prostate cancer (PC. Statistics for incidence and detectability of this pathology and its dynamics for recent years are represented. Brief analysis of other methods which are conveniently used for treatment of PC, such as radical prostatectomy and external-beam radiotherapy, was performed. Advantages and disadvantages of these methods have been discussed. Brief history about the development of brachytherapy from first experience to wide-spread use in clinical practice is reported. The detailed review of series of large trials from Russia and other countries for efficiency and safety of brachytherapy in patients with prostate cancer for recent 15 years is also represented. Two types of brachytherapy in current clinical oncology i.e. low-dose technique with permanent implantation of microsources and high-dose temporary isotope implantation, specifics of its application in different groups of patients have been described. The procedure of brachytherapy and its three main steps i.e. planning, implantation and control assessment after implantation have been characterized in details. The conclusion about benefits of using of brachytherapy in the treatment of prostate cancer as minimally invasive and efficient method was made. 

  20. Prophylactic tamsulosin (Flomax) in patients undergoing prostate 125I brachytherapy for prostate carcinoma: Final report of a double-blind placebo-controlled randomized study

    International Nuclear Information System (INIS)

    Elshaikh, Mohamed A.; Ulchaker, James C.; Reddy, Chandana A.; Angermeier, Kenneth W.; Klein, Eric A.; Chehade, Nabil; Altman, Andrew; Ciezki, Jay P.

    2005-01-01

    Purpose: To evaluate the effectiveness of prophylactic tamsulosin (Flomax) in reducing the urinary symptoms in patients undergoing 125 I prostate implantation (PI) for prostate adenocarcinoma. Methods and materials: This is a single-institution, double-blind, placebo-controlled, randomized trial for patients undergoing PI for prostate adenocarcinoma comparing prophylactic tamsulosin versus placebo. Eligibility criteria included patients not taking tamsulosin or other α-blockers treated with PI. The patients were randomly assigned to either tamsulosin (0.8 mg, orally once a day) or matched placebo. All patients started the medication 4 days before PI and continued for 60 days. The American Urologic Association (AUA) symptom index questionnaire was used to assess urinary symptoms. The AUA questionnaire was administered before PI for a baseline score and weekly for 8 weeks after PI. Patients were taken off the study if they developed urinary retention, had intolerable urinary symptoms, or wished to discontinue with the trial. Results: One hundred twenty-six patients were enrolled in this study from November 2001 to January 2003 (118 were evaluable: 58 in the tamsulosin arm and 60 in the placebo group). Pretreatment and treatment characteristics were comparably matched between the two groups. The urinary retention rate was 17% (10 patients) in the placebo group compared with 10% (6 patients) in the tamsulosin group (p = 0.3161). Eighty-eight percent (14 patients) of those who developed urinary retention experienced it within 2 weeks after the PI. Intolerable urinary symptoms were reported equally (10 patients in each group) with 70% occurring in the first 2 weeks after PI. There was a significant difference in mean AUA score in favor of tamsulosin at Week 5 after PI (p = 0.03). Conclusions: Prophylactic tamsulosin (0.8 mg/day) before prostate brachytherapy did not significantly affect urinary retention rates, but had a positive effect on urinary morbidity at Week 5

  1. Statistical differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the Iodine-125 brachytherapy seed

    International Nuclear Information System (INIS)

    Zeituni, Carlos A.; Moura, Eduardo S.; Rostelato, Maria Elisa C.M.; Manzoli, Jose E.; Moura, Joao Augusto; Feher, Anselmo; Karam, Dib

    2009-01-01

    In order to provide the dosimetry for Iodine-125 seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the response will not be the same. As a consequence, they must be measured one by one. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. Irradiations were performed using Iodine-125 seeds to guarantee the same absorbed dose of 5 Gy in each dosimeter. It has been used a Solid Water Phantom with three concentrically circle with 20 mm, 50 mm and 70 mm diameters. The angle of positions used was 0 deg, 30 deg, 60 deg and 90 deg. Of course there are 2 positions in 0 deg and 90 deg and 4 positions in 30 deg and 60 deg. These complete procedures were carried out five times in order to compare the data and minimize the systematic error. The iodine-125 seed used in the experiment was take off in each measure and put again turning his position 180 deg to guarantee the systematic error was minimized. This paper presents also a little discussion about the statistical difference in the measurement and the calculation procedure to determine the systematic error in these measurements. (author)

  2. Statistical differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the Iodine-125 brachytherapy seed

    Energy Technology Data Exchange (ETDEWEB)

    Zeituni, Carlos A.; Moura, Eduardo S.; Rostelato, Maria Elisa C.M.; Manzoli, Jose E.; Moura, Joao Augusto; Feher, Anselmo, E-mail: czeituni@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP) Sao Paulo, SP (Brazil); Karam, Dib [Universidade de Sao Paulo (USP Leste), Sao Paulo, SP (Brazil). Escola de Artes, Ciencias e Humanidades

    2009-07-01

    In order to provide the dosimetry for Iodine-125 seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the response will not be the same. As a consequence, they must be measured one by one. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. Irradiations were performed using Iodine-125 seeds to guarantee the same absorbed dose of 5 Gy in each dosimeter. It has been used a Solid Water Phantom with three concentrically circle with 20 mm, 50 mm and 70 mm diameters. The angle of positions used was 0 deg, 30 deg, 60 deg and 90 deg. Of course there are 2 positions in 0 deg and 90 deg and 4 positions in 30 deg and 60 deg. These complete procedures were carried out five times in order to compare the data and minimize the systematic error. The iodine-125 seed used in the experiment was take off in each measure and put again turning his position 180 deg to guarantee the systematic error was minimized. This paper presents also a little discussion about the statistical difference in the measurement and the calculation procedure to determine the systematic error in these measurements. (author)

  3. Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Luerman, Christine M.; Sowards, Keith T.

    2009-01-01

    Recently, several different models of 125 I and 103 Pd brachytherapy sources have been introduced in order to meet the increasing demand for prostate seed implants. These sources have different internal structures; hence, their TG-43 dosimetric parameters are not the same. In this study, the effects of the dosimetric differences among the sources on their clinical applications were evaluated. The quantitative and qualitative evaluations were performed by comparisons of dose distributions and dose volume histograms of prostate implants calculated for various designs of 125 I and 103 Pd sources. These comparisons were made for an identical implant scheme with the same number of seeds for each source. The results were compared with the Amersham model 6711 seed for 125 I and the Theragenics model 200 seed for 103 Pd using the same implant scheme.

  4. Biochemical disease-free survival following I-125 prostate implantation

    International Nuclear Information System (INIS)

    Beyer, David C.; Priestley, Joseph B.

    1995-01-01

    Purpose/Objective: To assess the five-year clinical and biochemical results of ultrasound-guided permanent I-125 brachytherapy in early prostate cancer. Biochemical disease-free survival (BDFS) is reported, using PSA follow-up and is compared to the surgical and radiation therapy literature. Materials and Methods: From 12/88 through 12/93, ultrasound-guided brachytherapy was preplanned with I-125 and delivered 16,000 cGy as the sole treatment in 499 patients. All were clinically staged as T1 or T2 - N0M0 adenocarcinoma of the prostate. Within the first year, 19 patients were lost to follow-up and have been excluded from further study. The remaining 480 patients form the basis of this report. Clinical status and PSA values were systematically recorded before and after treatment. Results: With a median follow-up of 35 months (3-70) the actuarial clinical local control is 83%. Both stage and grade are shown to predict for this endpoint. Actuarial BDFS is also correlated with stage, grade, and PSA at presentation. Biochemical disease-free survival at five years is 94% for T1, 70% for unilateral T2, and 34% for T2c tumors. Grade is also predictive, ranging from 85% in low-grade tumors to 30% in high-grade tumors. In a multivariate analysis, the pretreatment PSA is most highly correlated (p 10 had a BDFS of 40%. Complications have been few, with severe urinary urgency or dysuria in 4% and both incontinence and proctitis seen in 1%. Conclusion: While biochemical disease-free survival reports in the literature are immature and have short follow-up, our data compares favorably with studies following radical prostatectomy or radiation therapy. Further follow-up of this cohort is required. The complication rate is low and patient acceptance excellent. Permanent implantation of I-125 as the sole treatment for early prostate cancer is a viable alternative for patients with early stage and low- to moderate-grade cancers. The PSA provides significant prognostic information and

  5. Biochemical disease-free survival following I-125 prostate implantation

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, David C; Priestley, Joseph B

    1995-07-01

    Purpose/Objective: To assess the five-year clinical and biochemical results of ultrasound-guided permanent I-125 brachytherapy in early prostate cancer. Biochemical disease-free survival (BDFS) is reported, using PSA follow-up and is compared to the surgical and radiation therapy literature. Materials and Methods: From 12/88 through 12/93, ultrasound-guided brachytherapy was preplanned with I-125 and delivered 16,000 cGy as the sole treatment in 499 patients. All were clinically staged as T1 or T2 - N0M0 adenocarcinoma of the prostate. Within the first year, 19 patients were lost to follow-up and have been excluded from further study. The remaining 480 patients form the basis of this report. Clinical status and PSA values were systematically recorded before and after treatment. Results: With a median follow-up of 35 months (3-70) the actuarial clinical local control is 83%. Both stage and grade are shown to predict for this endpoint. Actuarial BDFS is also correlated with stage, grade, and PSA at presentation. Biochemical disease-free survival at five years is 94% for T1, 70% for unilateral T2, and 34% for T2c tumors. Grade is also predictive, ranging from 85% in low-grade tumors to 30% in high-grade tumors. In a multivariate analysis, the pretreatment PSA is most highly correlated (p < 0.0001). Patients with a normal pretreatment PSA enjoyed 93% BDFS, while those presenting with PSA > 10 had a BDFS of 40%. Complications have been few, with severe urinary urgency or dysuria in 4% and both incontinence and proctitis seen in 1%. Conclusion: While biochemical disease-free survival reports in the literature are immature and have short follow-up, our data compares favorably with studies following radical prostatectomy or radiation therapy. Further follow-up of this cohort is required. The complication rate is low and patient acceptance excellent. Permanent implantation of I-125 as the sole treatment for early prostate cancer is a viable alternative for patients with

  6. Can the prostate brachytherapy by permanent implants represent an alternative to external radiotherapy for the localised prostate cancers with intermediary risk?

    International Nuclear Information System (INIS)

    Farnault, B.; Duberge, T.; Salem, N.; Boher, J.M.; Gravis, G.; Bladou, F.; Jochen, W.; Resbeut, M.

    2009-01-01

    Purpose: the prostate brachytherapy stands out as treatment of low risk prostate cancers, but the data concerning its use as exclusive treatment of intermediary risk prostate cancer are rare. We present a retrospective analysis of intermediary risk prostate cancers which treatment was either an external conformal radiotherapy or an exclusive brachytherapy. conclusion: In this mono centric series, the brachytherapy brings excellent results in comparison with external conformal radiotherapy with dose escalation and could be proposed as alternative to patients suffering of intermediary risk prostate cancer. (N.C.)

  7. Procedure for determination of the decontamination of piping in the production of iodine-125 seeds; Procedimento para determinacao da descontaminacao de tubulacoes, na producao de sementes de iodo-125

    Energy Technology Data Exchange (ETDEWEB)

    Moura, J.A.; Moura, E.S.; Sprenger, F.E.; Nagatomi, H.R.; Zeituni, C.A.; Feher, A.; Manzoli, J.E.; Souza, C.D.; Rostelato, M.E.C.M., E-mail: elisaros@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Iodine-125 seeds are radioactive sources used in the prostate cancer treatment. This work objective was to determine the necessary conditions and procedures for decontamination of liquid transfer tubes when a radioactive material leakage occurs during the process of seed quality control

  8. Feasibility and clinical value of CT-guided {sup 125}I brachytherapy for metastatic soft tissue sarcoma after first-line chemotherapy failure

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Zhiqiang; Zhang, Yanling; Xiang, Zhanwang; Yan, Huzhen; Zhong, Zhihui; Gao, Fei; Zhang, Fujun [Sun Yat-Sen University Cancer Centre, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre for Cancer Medicine, Guangzhou (China); Zhang, Tao [Guangzhou Medical University, Department of Interventional Radiology and Vascular Anomalies, Guangzhou Women and Children' s Medical Centre, Guangzhou (China)

    2018-03-15

    To evaluate the feasibility and usefulness of computed tomography (CT)-guided iodine{sup 125} ({sup 125}I) brachytherapy for patients with metastatic soft tissue sarcoma (STS) after first-line chemotherapy failure. We recruited 93 patients with metastatic STS who had received first-line chemotherapy 4-6 times but developed progressive disease, from January 2010 to July 2015; 45 patients who had combined {sup 125}I brachytherapy and second-line chemotherapy (Group A), and 48 patients who received second-line CT only (Group B). In Group A, 49 {sup 125}I seed implantation procedures were performed in 45 patients with 116 metastatic lesions; the primary success rate was 91.1% (41/45), without life-threatening complications. Local control rates at 3, 6, 12, 24 and 36 months were 71.1%, 62.2%, 46.7%, 28.9% and 11.1% for Group A, and 72.9%, 54.2%, 18.8%, 6.3% and 0% for Group B. Mean progression-free survival differed significantly (Group A: 7.1±1.3 months; Group B: 3.6 ±1.1 months; P<0.001; Cox proportional hazards regression analysis), but overall survival did not significantly differ (Group A: 16.9 ±5.1 months; Group B: 12.1 ± 4.8 months). Group A showed better symptom relief and quality of life than Group B. CT-guided {sup 125}I brachytherapy is a feasible and valuable treatment for patients with metastatic STS. (orig.)

  9. Isotope and Patient Age Predict for PSA Spikes After Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Bostancic, Chelsea; Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Allen, Zachariah; Galbreath, Robert; Lief, Jonathan; Gutman, Sarah E.

    2007-01-01

    Purpose: To evaluate prostate-specific antigen (PSA) spikes after permanent prostate brachytherapy in low-risk patients. Methods and Materials: The study population consisted of 164 prostate cancer patients who were part of a prospective randomized trial comparing 103 Pd and 125 I for low-risk disease. Of the 164 patients, 61 (37.2%) received short-course androgen deprivation therapy. The median follow-up was 5.4 years. On average, 11.1 post-treatment PSA measurements were obtained per patient. Biochemical disease-free survival was defined as a PSA level of ≤0.40 ng/mL after nadir. A PSA spike was defined as an increase of ≥0.2 ng/mL, followed by a durable decline to prespike levels. Multiple parameters were evaluated as predictors for a PSA spike. Results: Of the 164 patients, 44 (26.9%) developed a PSA spike. Of the 46 hormone-naive 125 I patients and 57 hormone-naive 103 Pd patients, 21 (45.7%) and 8 (14.0%) developed a PSA spike. In the hormone-naive patients, the mean time between implantation and the spike was 22.6 months and 18.7 months for 125 I and 103 Pd, respectively. In patients receiving neoadjuvant androgen deprivation therapy, the incidence of spikes was comparable between isotopes ( 125 I 28.1% and 103 Pd 20.7%). The incidence of spikes was substantially different in patients 125 I and/or <65 years of age. Differences in isotope-related spikes are most pronounced in hormone-naive patients

  10. Disease-related effects of perioperative blood transfusions associated with 125I seed implantation for prostate carcinoma

    International Nuclear Information System (INIS)

    Petersen, J.P.; Schellhammer, P.F.; el-Mahdi, A.M.

    1990-01-01

    In some retrospective studies perioperative transfusions during oncologic surgery have been shown to decrease the time interval between surgery and local and/or distant recurrence of cancer. This study examines the disease-related effect, if any, of perioperative blood transfusions among 108 patients with localized carcinoma of the prostate treated by radioactive iodine-125 seed implantation of the prostate and lymphadenectomy. When all subjects were analyzed, there was no statistical difference of local and distant failure between the transfused and nontransfused groups. Patients with well-differentiated tumors had statistically fewer local recurrences (0% vs 22%, p = 0.036) if they were transfused perioperatively. However, the difference in distant metastases (0% vs 11%) was not statistically significant (p = 0.21). In contrast, patients with moderately and poorly differentiated disease receiving transfusions had more local recurrences and metastases, though this was not statistically significant. Our data suggest that there is no obvious evidence that perioperative blood transfusions have an adverse effect on local recurrence or distant metastases for iodine-125 seed implantation of carcinoma of the prostate

  11. Impact of prostate edema on cell survival and tumor control after permanent interstitial brachytherapy for early stage prostate cancers

    Science.gov (United States)

    Chen, Zhe (Jay); Roberts, Kenneth; Decker, Roy; Pathare, Pradip; Rockwell, Sara; Nath, Ravinder

    2011-01-01

    Previous studies have shown that the procedure-induced prostate edema during permanent interstitial brachytherapy (PIB) can cause significant variations in the dose delivered to the prostate gland. Because the clinical impact of edema-induced dose variations depends strongly on the magnitude of the edema, the temporal pattern of its resolution and its interplay with the decay of radioactivity and the underlying biological processes of tumor cells (such as tumor potential doubling time), we investigated the impact of edema-induced dose variations on the tumor cell survival and tumor control probability after PIB with the 131Cs, 125I and 103Pd sources used in current clinical practice. The exponential edema resolution model reported by Waterman et al. (Int. J. Radiat. Oncol. Biol. Phys. 41, 1069–1077–1998) was used to characterize the edema evolutions observed previously during clinical PIB for prostate cancer. The concept of biologically effective dose (BED), taking into account tumor cell proliferation and sublethal damage repair during dose delivery, was used to characterize the effects of prostate edema on cell survival and tumor control probability. Our calculation indicated that prostate edema, if not taken into account appropriately, can increase the cell survival and decrease the probability of local control of PIB. The edema-induced increase in cell survival increased with increasing edema severity, decreasing half-life for radioactive decay and decreasing energy of the photons energy emitted by the source. At the doses currently prescribed for PIB and for prostate cancer cells characterized by nominal radiobiology parameters recommended by AAPM TG-137, PIB using 125I sources was less affected by edema than PIB using 131Cs or 103Pd sources due to the long radioactive decay half-life of 125I. The effect of edema on PIB using 131Cs or 103Pd was similar. The effect of edema on 103Pd PIB was slightly greater, even though the decay half-life of 103Pd (17 days

  12. Role of TPS in 125I brachytherapy for orbital tumors

    International Nuclear Information System (INIS)

    Ren Ling; Dai Haojie; Li Quan

    2012-01-01

    Objective: To investigate the role of TPS in 125 I brachytherapy for orbital tumors. Methods: Sixty-six patients with orbital tumor treated with 125 I seeds from 2005 to 2009 were retrospectively analyzed. Forty-three patients were treated using TPS guided brachytherapy and the prescribed dose was 140 Gy. Other 23 patients were treated without TPS but simply implanted with 125 I seeds at 1 cm intervals in parallel with each other intraoperatively. CT and TPS quality verification were performed postoperatively in all patients. Also, CT and (or) MRI examination were performed at 3, 6, 12 and 24 months after brachytherapy for follow-up. χ 2 test and Kaplan-Meier survival analysis with log-rank significance test were used with SPSS 17.0. Results: A total of 1070 125 I seeds were implanted in 66 cases, on average, (16.2 ± 7.3) seeds for each patient. The satisfaction rates of postoperative quality verification in patients with and without TPS pre-plans were 79.07% (34/43) and 43.48% (10/23) respectively (χ 2 =8.542, P=0.003). Ten patients were lost in follow-up. Local recurrence rates in patients with favorable postoperative quality verification were 0 (0/37) in 3 months, 6.25% (2/32) in 6 months, 13.64% (3/22) in 12 months and 3/9 in 24 months respectively, which were significantly different from those (5.26% (1/19), 16.67% (3/18), 30.77% (4/13), 6/6) in the patients with inferior postoperative quality verification (χ 2 =9.017, P=0.0003). Conclusions: TPS plays an important role in 125 I brachytherapy for orbital tumors. Also, postoperative quality verification by TPS may help predict the local recurrence after brachytherapy. (authors)

  13. Efficacy of prophylactic single-dose therapy using fluoroquinolone for prostate brachytherapy

    International Nuclear Information System (INIS)

    Nomura, Takeo; Hirai, Kenichi; Yamasaki, Mutsushi; Inoue, Toru; Takahashi, Mika; Kawashima, Takayuki; Sato, Fuminori; Mimata, Hiromitsu

    2012-01-01

    There is little definitive evidence to guide the use of prophylactic antibiotics for prostate brachytherapy. The purpose of this study is to evaluate the incidence of postimplant infections in patients who receive antimicrobial prophylaxis with pazufloxacin (PZFX). A total of 84 patients who underwent prostate brachytherapy received a single intravenous dose of PZFX at 500 mg perioperatively for 1 day. No postimplant antibiotic medication was prescribed. Urinalysis, plasma white blood cell (WBC) count, and C reactive protein (CRP) levels were evaluated before the implantation, on the day after implantation, and on the 7th and 28th days after brachytherapy. None of the 84 patients (0.0%) developed a symptomatic urinary tract infection or had febrile infectious complications after brachytherapy. There were statistically significant elevations in the levels of erythrocytes, leukocytes, bacteria in urine, plasma WBC and CRP postoperatively, but these values did not exceed the normal range or were only slightly elevated on the day after brachytherapy (day 1) and on day 7. All laboratory examinations had returned to the normal range on day 28. Single-dose therapy with fluoroquinolone helps to prevent infections after prostate brachytherapy. (author)

  14. Radiation-Induced Leiomyosarcoma of the Prostate after Brachytherapy for Prostatic Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Hiroto Horiguchi

    2014-08-01

    Full Text Available Radiation therapy (RTx has been employed as a curative therapy for prostatic adenocarcinoma. RTx-induced sarcomas (RISs are rare, late adverse events, representing less than 0.2% of all irradiated patients. RISs are more aggressive tumors than prostatic adenocarcinomas. Herein, we present a case with RTx-induced prostatic leiomyosarcoma after permanent brachytherapy for prostatic adenocarcinoma. A 69-year-old male presented with dysuria and gross hematuria. Six years previously, he had been diagnosed with localized prostate cancer and was treated by permanent brachytherapy. Urethroscopy showed stenosis by a tumor at the prostate. Transurethral prostatectomy was performed for a diagnosis. Based on pathological findings, the diagnosis was leiomyosarcoma of the prostate. He was treated with three cycles of neoadjuvant chemotherapy (CTx that consisted of doxorubicin and ifosfamide (AI, followed by a prostatocystectomy with intrapelvic lymphadenectomy. The tumor extended from the prostate and infiltrated the bladder wall and serosa with lymphatic and venous invasion. The surgical margin was negative, and no residual prostatic adenocarcinoma was observed. The proportion of necrotic tumor cells by neoadjuvant CTx was around 50%. Subsequently, adjuvant CTx was offered, but the patient chose a follow-up without CTx. Local recurrence and lung metastasis were detected by computed tomography 3 months after the surgery. He was treated again with AI. However, CTx was not effective and he died 6 months after the operation. In conclusion, an effective treatment strategy for prostatic sarcoma should be developed in the near future, although the clinical feature of prostatic sarcoma remains unclear due to its rare incidence.

  15. Focal low-dose rate brachytherapy for the treatment of prostate cancer

    Directory of Open Access Journals (Sweden)

    Tong WY

    2013-09-01

    Full Text Available William Y Tong, Gilad Cohen, Yoshiya Yamada Memorial Sloan-Kettering Cancer Center, Department of Radiation Oncology, New York, NY, USA Abstract: Whole-gland low-dose rate (LDR brachytherapy has been a well-established modality of treating low-risk prostate cancer. Treatment in a focal manner has the advantages of reduced toxicity to surrounding organs. Focal treatment using LDR brachytherapy has been relatively unexplored, but it may offer advantages over other modalities that have established experiences with a focal approach. This is particularly true as prostate cancer is being detected at an earlier and more localized stage with the advent of better detection methods and newer imaging modalities. Keywords: prostate cancer, focal, low dose rate, brachytherapy

  16. Iodine-125 and Iodine-131 in the Thames Valley and other areas

    International Nuclear Information System (INIS)

    Howe, J.R.; Lloyd, M.K.; Bowlt, C.

    1985-01-01

    Part of the Iodine-125 and Iodine-131 waste from hospitals and research centres is discarded down drains and passes through sewage and water reclamation works into the river system. Relatively high concentration of radioiodine occur in outfalls that discharge into the river Thames, lower levels are found in the mainstream river and less still in the reservoirs and tap water supplies abstracted from the river. The pathway from waste to drinking water could account for the low levels of Iodine-125 found in the thyroid glands of some farm animals and human beings in the Thames valley

  17. Prostate brachytherapy in Ghana: our initial experience

    Directory of Open Access Journals (Sweden)

    James Edward Mensah

    2016-10-01

    Full Text Available Purpose: This study presents the experience of a brachytherapy team in Ghana with a focus on technology transfer and outcome. The team was initially proctored by experienced physicians from Europe and South Africa. Material and methods : A total of 90 consecutive patients underwent either brachytherapy alone or brachytherapy in combination with external beam radiotherapy for prostate carcinoma between July 2008 and February 2014 at Korle Bu Teaching Hospital, Accra, Ghana. Patients were classified as low-risk, intermediate, and high-risk according to the National Comprehensive Cancer Network (NCCN criteria. All low-risk and some intermediate risk group patients were treated with seed implantation alone. Some intermediate and all high-risk group patients received brachytherapy combined with external beam radiotherapy. Results: The median patient age was 64.0 years (range 46-78 years. The median follow-up was 58 months (range 18-74 months. Twelve patients experienced biochemical failure including one patient who had evidence of metastatic disease and died of prostate cancer. Freedom from biochemical failure rates for low, intermediate, and high-risk cases were 95.4%, 90.9%, and 70.8%, respectively. Clinical parameters predictive of biochemical outcome included: clinical stage, Gleason score, and risk group. Pre-treatment prostate specific antigen (PSA was not a statistically significant predictor of biochemical failure. Sixty-nine patients (76.6% experienced grade 1 urinary symptoms in the form of frequency, urgency, and poor stream. These symptoms were mostly self-limiting. Four patients needed catheterization for urinary retention (grade 2. One patient developed a recto urethral fistula (grade 3 following banding for hemorrhoids. Conclusions : Our results compare favorably with those reported by other institutions with more extensive experience. We believe therefore that, interstitial permanent brachytherapy can be safely and effectively

  18. Results of a dummy run of postimplant dosimetry between multi-institutional centers in prostate brachytherapy with 125I seeds

    International Nuclear Information System (INIS)

    Aoki, Manabu; Yorozu, Atsunori; Dokiya, Takushi

    2009-01-01

    The purpose of this study was to determine the reproducibility and precision of postimplant dosimetry following 125 I prostate brachytherapy (PB) and to evaluate the effects of learning and experience in CT-based postimplant dosimetry. One-month postimplant CT data from two patients who underwent PB alone or combined therapy (PB+external beam radiation therapy (EBRT)) were sent to 28 institutions for postimplant dosimetry and analyzed in 2006 (study 1). Similarly, 1-month postimplant CT data from two other patients were also analyzed in 2008 (study 2; 23 institutions). For both modalities in studies 1 and 2, the variance of the difference between CT-based D90 at each institution and CT/MRI fusion-based D90 was estimated. In monotherapy, F test and Mann-Whitney U test revealed no significant difference in the variance in studies 1 and 2 (P=0.72, 0.46). In combined therapy, the variance significantly converged in study 2 compared with study 1 (P<0.05). Even in the two studies, however, the difference between the median CT-based D90 and fusion-based D90 was at least 20-30 Gy. Marked interobserver variability was seen in the prostate volume and D90 with CT alone. The precision of postimplant dosimetry based on CT alone was revealed to be limited. (author)

  19. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Samia de Freitas, E-mail: samiabrandao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Campos, Tarcisio Passos Ribeiro de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2013-06-15

    Objective: comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and methods: simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results: intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively, on the healthy tissue, on the balloon periphery and on the /{sub 1} and /{sub 2} tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively on the healthy tissue, on the target tumor and on the /{sub 1} and /{sub 2} infiltration zones. Conclusion: Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones. (author)

  20. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Directory of Open Access Journals (Sweden)

    Samia de Freitas Brandao

    2013-07-01

    Full Text Available Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

  1. Temporal relationship between prostate brachytherapy and the diagnosis of colorectal cancer

    International Nuclear Information System (INIS)

    Gutman, Sarah A.; Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Allen, Zachariah A.; Galbreath, Robert W.; Adamovich, Edward

    2006-01-01

    Purpose: To identify the location of pretreatment and posttreatment colorectal malignancies and posttreatment colorectal polyps in patients with clinically localized prostate cancer managed with brachytherapy. Methods and Materials: From April 1995 through July 2004, 1,351 consecutive patients underwent brachytherapy for clinical stage T1b-T3a (American Joint Committee on Cancer, 2002) prostate cancer. Supplemental external beam radiotherapy (XRT) was administered to 699 patients. The median follow-up was 4.6 years. Operative and pathology reports were reviewed for all patients with pretreatment and posttreatment colorectal cancer and posttreatment colorectal polyps. Multiple parameters were evaluated for the development of colorectal cancer or colorectal polyps. Results: Colorectal cancer was diagnosed in 23 and 25 patients before and after prostate brachytherapy, respectively. No differences were identified in the distribution of colorectal cancers either before or after treatment (3 and 4 rectal cancers in the pre- and postbrachytherapy cohorts). Thirty-five of the 48 colorectal cancers (73%) were diagnosed within 5 years of brachytherapy with a peak incidence 1 year after brachytherapy. One hundred ninety-two colorectal polyps were diagnosed after brachytherapy, 160 (83%) occurred within 4 years of brachytherapy, and only 27 (14%) were located in the rectum. In multivariate Cox regression analysis, prostate D 9 (minimum percentage of the dose covering 90% of the target volume) predicted for posttreatment colorectal cancer. Rectal polyps were most closely related to patient age and percent positive biopsies, whereas sigmoid/colon polyps were best predicted by patient age, planning volume, and supplemental XRT. Conclusions: Colorectal cancer was diagnosed with equal frequency before and after brachytherapy with comparable geographic distributions. In addition, the vast majority of postbrachytherapy colorectal polyps were located beyond the confines of the rectum

  2. Assessment of I-125 seed implant accuracy when using the live-planning technique for low dose rate prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Moorrees Joshua

    2012-11-01

    Full Text Available Abstract Background Low risk prostate cancers are commonly treated with low dose rate (LDR brachytherapy involving I-125 seeds. The implementation of a ‘live-planning’ technique at the Royal Adelaide Hospital (RAH in 2007 enabled the completion of the whole procedure (i.e. scanning, planning and implant in one sitting. ‘Live-planning’ has the advantage of a more reliable delivery of the planned treatment compared to the ‘traditional pre-plan’ technique (where patient is scanned and planned in the weeks prior to implant. During live planning, the actual implanted needle positions are updated real-time on the treatment planning system and the dosimetry is automatically recalculated. The aim of this investigation was to assess the differences and clinical relevance between the planned dosimetry and the updated real-time implant dosimetry. Methods A number of 162 patients were included in this dosimetric study. A paired t-test was performed on the D90, V100, V150 and V200 target parameters and the differences between the planned and implanted dose distributions were analysed. Similarly, dosimetric differences for the organs at risk (OAR were also evaluated. Results Small differences between the primary dosimetric parameters for the target were found. Still, the incidence of hotspots was increased with approximately 20% for V200. Statistically significant increases were observed in the doses delivered to the OAR between the planned and implanted data; however, these increases were consistently below 3% thus probably without clinical consequences. Conclusions The current study assessed the accuracy of prostate implants with I-125 seeds when compared to initial plans. The results confirmed the precision of the implant technique which RAH has in place. Nevertheless, geographical misses, anatomical restrictions and needle displacements during implant can have repercussions for centres without live-planning option if dosimetric changes are not

  3. The PROSPER robot for prostate brachytherapy: design, development and preclinical evaluation

    International Nuclear Information System (INIS)

    Long, J.A.

    2012-01-01

    Objectives: reporting the design, development and experiments of a new robotic system for prostate brachytherapy including prostate tracking and MRI to Ultrasound registration. Material and methods: a robot for trans-perineal needle insertion has been developed. It includes the ability to track the prostate position and shape. Experiments on 90 targets inside 9 deformable phantoms have been conducted. A feasibility on 2 cadavers has also been performed. The robot had to place glass seeds simulating brachytherapy seeds as close as possible to physical targets included into the phantom or inside the prostates. A post-operative CT scan of the phantom or prostate was performed in order to measure the accuracy of the system. Results: the median accuracy was 2.73 mm with a median prostate motion of 5.46 mm. The accuracy in the base region was superior to the accuracy in the apex region (2.28 mm vs 3.83 mm, p≤0.01) and was not significantly different for horizontal or oblique needles (2.7 vs 2.82 mm, p=0.18). Cadaver experiments demonstrated that the approach was feasible and that the robot could be used in a real clinical environment. Conclusion: the robot for prostate brachytherapy is the first system enabling prostate tracking. Targets can be accurately reached despite prostate motion and deformation. It could be applied to focal therapy for prostate cancer. (author)

  4. The impact of prostate edema on cell survival and tumor control after permanent interstitial brachytherapy for early stage prostate cancers

    International Nuclear Information System (INIS)

    Chen Zhe; Roberts, Kenneth; Decker, Roy; Pathare, Pradip; Rockwell, Sara; Nath, Ravinder

    2011-01-01

    Previous studies have shown that procedure-induced prostate edema during permanent interstitial brachytherapy (PIB) can cause significant variations in the dose delivered to the prostate gland. Because the clinical impact of edema-induced dose variations strongly depends on the magnitude of the edema, the temporal pattern of its resolution and its interplay with the decay of radioactivity and the underlying biological processes of tumor cells (such as tumor potential doubling time), we investigated the impact of edema-induced dose variations on the tumor cell survival and tumor control probability after PIB with the 131 Cs, 125 I and 103 Pd sources used in current clinical practice. The exponential edema resolution model reported by Waterman et al (1998 Int. J. Radiat. Oncol. Biol. Phys. 41 1069-77) was used to characterize the edema evolutions previously observed during clinical PIB for prostate cancer. The concept of biologically effective dose, taking into account tumor cell proliferation and sublethal damage repair during dose delivery, was used to characterize the effects of prostate edema on cell survival and tumor control probability. Our calculation indicated that prostate edema, if not appropriately taken into account, can increase the cell survival and decrease the probability of local control of PIB. The magnitude of an edema-induced increase in cell survival increased with increasing edema severity, decreasing half-life of radioactive decay and decreasing photon energy emitted by the source. At the doses currently prescribed for PIB and for prostate cancer cells characterized by nominal radiobiology parameters recommended by AAPM TG-137, PIB using 125 I sources was less affected by edema than PIB using 131 Cs or 103 Pd sources due to the long radioactive decay half-life of 125 I. The effect of edema on PIB using 131 Cs or 103 Pd was similar. The effect of edema on 103 Pd PIB was slightly greater, even though the decay half-life of 103 Pd (17 days) is

  5. High-dose regions versus likelihood of cure after prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Merrick, Gregory; Sutlief, Steven; True, Laurence; Butler, Wayne

    2005-01-01

    Purpose: To analyze the effect of high-dose regions on biochemical cancer control rates after prostate brachytherapy. Methods and Materials: Patients with 1997 American Joint Committee on Cancer clinical Stage T1c-T2a prostate carcinoma (Gleason grade 5-6, prostate-specific antigen level 4-10 ng/mL) were randomized to implantation with 125 I (144 Gy) vs. 103 Pd (125 Gy, National Institute of Standards and Technology 1999). Isotope implantation was performed by standard techniques, using a modified peripheral loading pattern. Of the 313 patients entered in the protocol, 270 were included in this analysis. The 125 I source strength ranged from 0.4 to 0.89 mCi (median, 0.55 mCi), and the 103 Pd source strength ranged from 1.3 to 1.6 mCi (median, 1.5 mCi). CT was performed within 4 h after implantation. The dosimetric parameters analyzed included the percentage of the postimplant prostate volume covered by the 100%, 150%, 200%, and 300% prescription dose (V 100 , V 150 , V 200 , and V 300 , respectively). The median time to the last follow-up for patients without failure was 2.7 years. Freedom from biochemical failure was defined as a serum prostate-specific antigen level of ≤0.5 ng/mL at last follow-up. Patients were censored at last follow-up if their serum prostate-specific antigen level was still decreasing. Results: The mean V 100 , V 150 , V 200 , and V 300 value was 90% (±8%), 63% (±14), 35% (±13%), and 14% (±7%), respectively. Patients with a V 100 of ≥90% had a 3-year freedom from biochemical failure rate of 96% vs. 87% for those with a V 100 of 100 of ≥90% were analyzed, no relationship was found between higher dose regions and the likelihood of cancer control. This lack of effect on biochemical control was apparent for both isotopes. Conclusion: High-dose regions do not appear to affect cancer control rates, as long as >90% of the prostate volume is covered by the prescription dose

  6. Prostate Brachytherapy in Men ≥75 Years of Age

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Wallner, Kent E.; Galbreath, Robert W.; Butler, Wayne M.; Brammer, Sarah G.; Allen, Zachariah A.; Adamovich, Edward

    2008-01-01

    Purpose: To evaluate cause-specific survival (CSS), biochemical progression-free survival (bPFS), and overall survival (OS) in prostate cancer patients aged ≥75 years undergoing brachytherapy with or without supplemental therapies. Methods and Materials: Between April 1995 and August 2004, 145 consecutive patients aged ≥75 years underwent permanent prostate brachytherapy. Median follow-up was 5.8 years. Biochemical progression-free survival was defined by a prostate-specific antigen level ≤0.40 ng/mL after nadir. Patients with metastatic prostate cancer or hormone-refractory disease without obvious metastases who died of any cause were classified as dead of prostate cancer. All other deaths were attributed to the immediate cause of death. Multiple clinical, treatment, and dosimetric parameters were evaluated for impact on survival. Results: Nine-year CSS, bPFS, and OS rates for the entire cohort were 99.3%, 97.1%, and 64.5%, respectively. None of the evaluated parameters predicted for CSS, whereas bPFS was most closely predicted by percentage positive biopsies. Overall survival and non-cancer deaths were best predicted by tobacco status. Thirty-seven patients have died, with 83.8% of the deaths due to cardiovascular disease (22 patients) or second malignancies (9 patients). To date, only 1 patient (0.7%) has died of metastatic prostate cancer. Conclusions: After brachytherapy, high rates of CSS and bPFS are noted in elderly prostate cancer patients. Overall, approximately 65% of patients are alive at 9 years, with survival most closely related to tobacco status. We believe our results support an aggressive locoregional approach in appropriately selected elderly patients

  7. Severe rectal complications after prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Sutlief, Stephen; Bergsagel, Carl; Merrick, Gregory S.

    2015-01-01

    Purpose: Some investigators have reported severe rectal complications after brachytherapy. Due to the low number of such events, their relationship to dosimetric parameters has not been well characterized. Methods and materials: A total of 3126 patients were treated with low dose rate brachytherapy from 1998 through 2010. 2464 had implant alone, and 313 had implant preceded by 44–46 Gy supplemental external beam radiation (EBRT). Post-implant dosimetry was based on a CT scan obtained on the day of implant, generally within 30 min of the procedure. Every patient’s record was reviewed for occurrence of rectal complications. Results: Eight of 2464 patients (0.32%) treated with brachytherapy alone developed a radiation-related rectal fistula. Average prostatic and rectal dose parameters were moderately higher for fistula patients than for patients without a severe rectal complication. For instance, the average R100 was 1.2 ± 0.75 cc for fistula patients, versus 0.37 ± 0.88 cc for non-fistula patients. However, the fistula patients’ values were well within the range of values for patients without a rectal complication. Four patients had some attempt at repair or reconstruction, but long-term functional outcomes were not favorable. Conclusions: Rectal fistulas are a very uncommon potential complication of prostate brachytherapy, which can occur even in the setting of acceptable day 0 rectal doses. Their occurrence is not easily explained by standard dosimetric or clinical factors

  8. Dosimetry Modeling for Focal Low-Dose-Rate Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Al-Qaisieh, Bashar [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Mason, Josh, E-mail: joshua.mason@nhs.net [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Bownes, Peter; Henry, Ann [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Dickinson, Louise [Division of Surgery and Interventional Science, University College London, London (United Kingdom); Department of Radiology, Northwick Park Hospital, London North West NHS Trust, London (United Kingdom); Ahmed, Hashim U. [Division of Surgery and Interventional Science, University College London, London (United Kingdom); University College London Hospital, London (United Kingdom); Emberton, Mark [University College London Hospital, London (United Kingdom); Langley, Stephen [St Luke' s Cancer Centre, Guildford (United Kingdom)

    2015-07-15

    Purpose: Focal brachytherapy targeted to an individual lesion(s) within the prostate may reduce side effects experienced with whole-gland brachytherapy. The outcomes of a consensus meeting on focal prostate brachytherapy were used to investigate optimal dosimetry of focal low-dose-rate (LDR) prostate brachytherapy targeted using multiparametric magnetic resonance imaging (mp-MRI) and transperineal template prostate mapping (TPM) biopsy, including the effects of random and systematic seed displacements and interseed attenuation (ISA). Methods and Materials: Nine patients were selected according to clinical characteristics and concordance of TPM and mp-MRI. Retrospectively, 3 treatment plans were analyzed for each case: whole-gland (WG), hemi-gland (hemi), and ultra-focal (UF) plans, with 145-Gy prescription dose and identical dose constraints for each plan. Plan robustness to seed displacement and ISA were assessed using Monte Carlo simulations. Results: WG plans used a mean 28 needles and 81 seeds, hemi plans used 17 needles and 56 seeds, and UF plans used 12 needles and 25 seeds. Mean D90 (minimum dose received by 90% of the target) and V100 (percentage of the target that receives 100% dose) values were 181.3 Gy and 99.8% for the prostate in WG plans, 195.7 Gy and 97.8% for the hemi-prostate in hemi plans, and 218.3 Gy and 99.8% for the focal target in UF plans. Mean urethra D10 was 205.9 Gy, 191.4 Gy, and 92.4 Gy in WG, hemi, and UF plans, respectively. Mean rectum D2 cm{sup 3} was 107.5 Gy, 77.0 Gy, and 42.7 Gy in WG, hemi, and UF plans, respectively. Focal plans were more sensitive to seed displacement errors: random shifts with a standard deviation of 4 mm reduced mean target D90 by 14.0%, 20.5%, and 32.0% for WG, hemi, and UF plans, respectively. ISA has a similar impact on dose-volume histogram parameters for all plan types. Conclusions: Treatment planning for focal LDR brachytherapy is feasible. Dose constraints are easily met with a notable

  9. Simulation of measurement absorbed dose on prostate brachytherapy with radius of prostate 2 cm using MCNP5 with seed implant model isoaid AdvantageTM IAPd-103A

    International Nuclear Information System (INIS)

    Poundra Setiawan; Suharyana; Riyatun

    2015-01-01

    Simulation of measurement absorbed dose on prostate brachytherapy with radius of prostate 2 cm using MCNP5 with seed implant model IsoAid Advantage TM IAPd-103A has been conducted. 103 Pd used as a radioactive source in the seed implant and it has energy gamma emission 20,8 keV with half live 16,9 days and has activity 4 mCi. The prostate cancer is modeled with spherical and it has radius 3 cm, after planting the seed implant 103 Pdover 24,4 days, prostate cancer has absorbed dose 2,172Gy. Lethal dose maximum use 103 Pd is 125 Gy and it was reached with 59 seeds. (author)

  10. Erectile Function Durability Following Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Taira, Al V.; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Wallner, Kent E.; Kurko, Brian S.; Anderson, Richard; Lief, Jonathan H.

    2009-01-01

    Purpose: To evaluate long-term changes in erectile function following prostate brachytherapy. Methods and Materials: This study included 226 patients with prostate cancer and preimplant erectile function assessed by the International Index of Erectile Function-6 (IIEF-6) who underwent brachytherapy in two prospective randomized trials between February 2001 and January 2003. Median follow-up was 6.4 years. Pre- and postbrachytherapy potency was defined as IIEF-6 ≥ 13 without pharmacologic or mechanical support. The relationship among clinical, treatment, and dosimetric parameters and erectile function was examined. Results: The 7-year actuarial rate of potency preservation was 55.6% with median postimplant IIEF of 22 in potent patients. Potent patients were statistically younger (p = 0.014), had a higher preimplant IIEF (p < 0.001), were less likely to be diabetic (p = 0.002), and were more likely to report nocturnal erections (p = 0.008). Potency preservation in men with baseline IIEF scores of 29-30, 24-28, 18-23, and 13-17 were 75.5% vs. 73.6%, 51.7% vs. 44.8%, 48.0% vs. 40.0%, and 23.5% vs. 23.5% in 2004 vs. 2008. In multivariate Cox regression analysis, preimplant IIEF, hypertension, diabetes, prostate size, and brachytherapy dose to proximal penis strongly predicted for potency preservation. Impact of proximal penile dose was most pronounced for men with IIEF of 18-23 and aged 60-69. A significant minority of men who developed postimplant impotence ultimately regained erectile function. Conclusion: Potency preservation and median IIEF scores following brachytherapy are durable. Thoughtful dose sparing of proximal penile structures and early penile rehabilitation may further improve these results.

  11. Characterization and storage of liquid wastes containing 125Iodine in the laboratory for production of brachytherapy sources - IPEN

    International Nuclear Information System (INIS)

    Carvalho, Vitória S.; Souza, Daiane C.B. de; Barbosa, Nayane K.O.; Rodrigues, Bruna T.; Nogueira, Beatriz R.; Costa, Osvaldo L. da; Zeituni, Carlos A.; Vicente, Roberto; Rostelato, Maria E.C.M.

    2017-01-01

    Radioactive sources of Iodine-125 for medical applications have been developed at the Institute for Energy and Nuclear Research (IPEN) to meet the growing demand for medical applications such as brachytherapy. A dedicated laboratory is already being implemented at IPEN. Part of the processes involved in the production of sealed sources generate radioactive wastes that despite the short half-life (<100 days) have radioactive activity above the levels of exemption established by the Brazilian National Nuclear Energy Commission. Therefore, these wastes should receive appropriate treatment and storage until they reach the levels of release into the environment. This work aims to determine the volumes of the liquid wastes generated during the production stages of the sources, as well as to propose a temporary storage system for such wastes. The applied methodology consisted in determining the volumes of wastes generated in each production cell according to the manufacturing steps. After that, activities and activity concentrations were calculated for each container used for temporary storage inside the production laboratory. The total volume stored for one year in the temporary storage, as well as the rate of entry and exit of the liquid wastes were calculated according to the source production demand and the decay time of the radionuclide, respectively. The main results showed that the time required to reach sanitary sewage disposal values is within the period of operation of the facility. The total volume generated is also within the facility's temporary storage capacity

  12. Fast dose kernel interpolation using Fourier transform with application to permanent prostate brachytherapy dosimetry.

    Science.gov (United States)

    Liu, Derek; Sloboda, Ron S

    2014-05-01

    Boyer and Mok proposed a fast calculation method employing the Fourier transform (FT), for which calculation time is independent of the number of seeds but seed placement is restricted to calculation grid points. Here an interpolation method is described enabling unrestricted seed placement while preserving the computational efficiency of the original method. The Iodine-125 seed dose kernel was sampled and selected values were modified to optimize interpolation accuracy for clinically relevant doses. For each seed, the kernel was shifted to the nearest grid point via convolution with a unit impulse, implemented in the Fourier domain. The remaining fractional shift was performed using a piecewise third-order Lagrange filter. Implementation of the interpolation method greatly improved FT-based dose calculation accuracy. The dose distribution was accurate to within 2% beyond 3 mm from each seed. Isodose contours were indistinguishable from explicit TG-43 calculation. Dose-volume metric errors were negligible. Computation time for the FT interpolation method was essentially the same as Boyer's method. A FT interpolation method for permanent prostate brachytherapy TG-43 dose calculation was developed which expands upon Boyer's original method and enables unrestricted seed placement. The proposed method substantially improves the clinically relevant dose accuracy with negligible additional computation cost, preserving the efficiency of the original method.

  13. Brachytherapy versus prostatectomy in localized prostate cancer: Results of a French multicenter prospective medico-economic study

    International Nuclear Information System (INIS)

    Buron, Catherine; Le Vu, Beatrice; Cosset, Jean-Marc; Pommier, Pascal; Peiffert, Didier; Delannes, Martine; Flam, Thierry; Guerif, Stephane; Salem, Naji; Chauveinc, Laurent; Livartowski, Alain

    2007-01-01

    Purpose: To prospectively compare health-related quality of life (HRQOL), patient-reported treatment-related symptoms, and costs of iodine-125 permanent implant interstitial brachytherapy (IB) with those of radical prostatectomy (RP) during the first 2 years after these treatments for localized prostate cancer. Methods and Materials: A total of 435 men with localized low-risk prostate cancer, from 11 French hospitals, treated with IB (308) or RP (127), were offered to complete the European Organization for Research and Treatment of Cancer core Quality of Life Questionnaire QLQ-C30 version 3 (EORTC QLQ-C30) and the prostate cancer specific EORTC QLQ-PR25 module before and at the end of treatment, 2, 6, 12, 18, and 24 months after treatment. Repeated measures analysis of variance and analysis of covariance were conducted on HRQOL changes. Comparative cost analysis covered initial treatment, hospital follow-up, outpatient and production loss costs. Results: Just after treatment, the decrease of global HRQOL was less pronounced in the IB than in the RP group, with a 13.5 points difference (p < 0.0001). A difference slightly in favor of RP was observed 6 months after treatment (-7.5 points, p = 0.0164) and was maintained at 24 months (-8.2 points, p = 0.0379). Impotence and urinary incontinence were more pronounced after RP, whereas urinary frequency, urgency, and urination pain were more frequent after IB. Mean societal costs did not differ between IB ( Euro 8,019 at T24) and RP ( Euro 8,715 at T24, p = 0.0843) regardless of the period. Conclusions: This study suggests a similar cost profile in France for IB and RP but with different HRQOL and side effect profiles. Those findings may be used to tailor localized prostate cancer treatments to suit individual patients' needs

  14. Twelve-Month Prostate-Specific Antigen Values and Perineural Invasion as Strong Independent Prognostic Variables of Long-Term Biochemical Outcome After Prostate Seed Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ding, William, E-mail: billyding888@gmail.com [Department of Radiation Oncology, California Pacific Medical Center, San Francisco, California (United States); Lee, John [Department of Radiation Oncology, California Pacific Medical Center, San Francisco, California (United States); Chamberlain, David [Department of Radiation Oncology, St. Mary' s Regional Medical Center, Reno, Nevada (United States); Cunningham, James [Carson Urology, Carson City, Nevada (United States); Yang Lixi [Department of Radiation Oncology, California Pacific Medical Center, San Francisco, California (United States); Tay, Jonathan [Department of Radiation Oncology, St. Mary' s Regional Medical Center, Reno, Nevada (United States)

    2012-11-15

    Purpose: To determine whether post-treatment prostate-specific antigen (ptPSA) values at 12 months and other clinical parameters predict long-term PSA relapse-free survival (PRFS) following prostate seed brachytherapy. Methods and Materials: Records of 204 hormone-naieve patients with localized adenocarcinoma of the prostate treated at St. Mary's Regional Medical Center in Reno, NV, and at Carson Tahoe Regional Medical Center in Carson City, NV, between 1998 and 2003, using I-125 or Pd-103 seed brachytherapy, were retrospectively analyzed. Treatment planning was done using a preplanned, modified peripheral loading technique. A total of 185 of 204 patients had PSA records at 12 months after implant. Variables included were age, initial pretreatment PSA, Gleason score, T stage, National Comprehensive Cancer Network (NCCN) risk group (RG), perineural invasion (PNI), external beam boost, dose, and ptPSA levels at 12 months with cutpoints at {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml. Results: Median follow-up was 80 months, and median age was 69 years. The numbers of patients stratified by NCCN low, intermediate, and high RG were 110:65:10, respectively. Monotherapy and boost prescription doses were 145 Gy and 110 Gy for I-125, and 125 Gy and 100 Gy for Pd-103 seeds, respectively. The median dose (D90) was 95.4% of the prescribed dose. The 5-year PRFS at the 12-months ptPSA levels of {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml were 98.5%, 85.7%, 61.5%, and 22.2%, respectively. The 10-year PRFS at the 12-months ptPSA levels of {<=}1 and 1.01 to 2.00 ng/ml were 90.5% and 85.7%, respectively. In multivariate analysis, both ptPSA and PNI were significant independent predictors of PRFS. Hazard ratios (HR) for ptPSA levels at {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml at 12 months were 1, 4.96, 27.57, and 65.10, respectively. PNI had an HR of 6.1 (p = 0.009). Conclusions: Presence of PNI and ptPSA values at 12 months are strong prognostic

  15. Twelve-Month Prostate-Specific Antigen Values and Perineural Invasion as Strong Independent Prognostic Variables of Long-Term Biochemical Outcome After Prostate Seed Brachytherapy

    International Nuclear Information System (INIS)

    Ding, William; Lee, John; Chamberlain, David; Cunningham, James; Yang Lixi; Tay, Jonathan

    2012-01-01

    Purpose: To determine whether post-treatment prostate-specific antigen (ptPSA) values at 12 months and other clinical parameters predict long-term PSA relapse-free survival (PRFS) following prostate seed brachytherapy. Methods and Materials: Records of 204 hormone-naïve patients with localized adenocarcinoma of the prostate treated at St. Mary’s Regional Medical Center in Reno, NV, and at Carson Tahoe Regional Medical Center in Carson City, NV, between 1998 and 2003, using I-125 or Pd-103 seed brachytherapy, were retrospectively analyzed. Treatment planning was done using a preplanned, modified peripheral loading technique. A total of 185 of 204 patients had PSA records at 12 months after implant. Variables included were age, initial pretreatment PSA, Gleason score, T stage, National Comprehensive Cancer Network (NCCN) risk group (RG), perineural invasion (PNI), external beam boost, dose, and ptPSA levels at 12 months with cutpoints at ≤1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml. Results: Median follow-up was 80 months, and median age was 69 years. The numbers of patients stratified by NCCN low, intermediate, and high RG were 110:65:10, respectively. Monotherapy and boost prescription doses were 145 Gy and 110 Gy for I-125, and 125 Gy and 100 Gy for Pd-103 seeds, respectively. The median dose (D90) was 95.4% of the prescribed dose. The 5-year PRFS at the 12-months ptPSA levels of ≤1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml were 98.5%, 85.7%, 61.5%, and 22.2%, respectively. The 10-year PRFS at the 12-months ptPSA levels of ≤1 and 1.01 to 2.00 ng/ml were 90.5% and 85.7%, respectively. In multivariate analysis, both ptPSA and PNI were significant independent predictors of PRFS. Hazard ratios (HR) for ptPSA levels at ≤1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml at 12 months were 1, 4.96, 27.57, and 65.10, respectively. PNI had an HR of 6.1 (p = 0.009). Conclusions: Presence of PNI and ptPSA values at 12 months are strong prognostic variables for

  16. Postoperative [{sup 125}I] seed brachytherapy in the treatment of acinic cell carcinoma of the parotid gland. With associated risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Ming-hui; Zhang, Jian-Guo; Zhang, Jie; Zheng, Lei; Liu, Shu-ming; Huang, Ming-wei; Shi, Yan [Peking Univ. School and Hospital of Stomatology, Beijing (China). Dept. of Oral and Maxillofacial Surgery

    2014-11-15

    This retrospective study was undertaken to analyze data from patients receiving iodine-125 ([{sup 125}I]) seed brachytherapy postoperatively for the treatment of acinic cell carcinoma (ACC) of the parotid gland along with the following risk factors: residual tumor, recurrent tumor, facial nerve invasion, positive resection margins, advanced tumor stage, or tumor spillage. Twenty-nine patients with ACC (17 females, 12 males; age range, 13-73 years; median age, 37.3 years) were included. Median follow-up was 58.2 months (range, 14-122 months). Patients received [{sup 125}I] seed brachytherapy (median actuarial D90, 177 Gy) 3-41 days (median, 14 days) following surgery. Radioactivity was 18.5-33.3 MBq per seed, and the prescription dose was 80-120 Gy. The 3-, 5-, and 10-year rates of local control were 93.1, 88.7, and 88.7 %, respectively; overall survival was 96.6, 92, and 92 %; disease-free survival was 93.1, 88.4, and 88.4 %; and freedom from distant metastasis was 96.6, 91.2, and 91.2 %. Lymph node metastases were absent in all patients, although two patients died with distant metastases. Facial nerve recovery was quick, and no severe radiotherapy-related complications were noted. Recurrence history, local recurrence, and distant metastasis significantly affected overall survival. Postoperative [{sup 125}I] seed brachytherapy is effective in treating ACC and has minor complications. Patients with a history of recurrence showed poor prognosis and were more likely to experience disease recurrence and develop metastases. (orig.) [German] Diese retrospektive Studie wurde durchgefuehrt, um die Daten von Patienten zu analysieren, die postoperativ eine Seed-Brachytherapie mit Iod-125 ([{sup 125}I]) zur Behandlung von Azinuszellkarzinomen der Ohrspeicheldruese mit begleitenden Risikofaktoren, wie Residualtumor, Rezidivtumor, Invasion in den N. facialis, positive (= nicht tumorfreie) Resektionsraender, fortgeschrittenes Tumorstadium oder lokale Verbreitung von Tumorzellen

  17. SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hueso-Gonzalez, F [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology, Dresden (Germany); Vijande, J [University of Valencia, Burjassot and IFIC (CSIC-UV) (Spain); Ballester, F [University of Valencia, Burjassot (Spain); Perez-Calatayud, J [Hospital Clinica Benidorm, Benidorm, and Hospital Universitari i Politecnic La Fe, Valencia (Spain); Siebert, F [Clinic of Radiotherapy (Radiooncology), Kiel (Germany)

    2016-06-15

    Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43), ii) a MC study using the Penelope2009 code, and iii) RayStretch. To analyse the performance of RayStretch, calcifications located in the prostate lobules covering 11% of the total prostate volume and larger calcifications located in the lobules and underneath the urethra for a total occupied volume of 30% were considered. Three mass densities (1.05, 1.20, and 1.35 g/cm3) were explored for the calcifications. Therefore, 6 different scenarios ranging from small low density calcifications to large high density ones have been discussed. Results: DVH and D90 results given by RayStretch agree within 1% with the full MC simulations. Although no effort has been done to improve RayStretch numerical performance, its present implementation is able to evaluate a clinical implant in a few seconds to the same level of accuracy as a detailed MC calculation. Conclusion: RayStretch is a robust method for heterogeneity corrections in prostate BT supported on TG-43 data. Its compatibility with commercial TPSs and its high calculation speed makes it feasible for use in clinical settings for improving treatment quality. It will allow in a second phase of this project, its use during intraoperative ultrasound planning. This study was partly supported by a fellowship grant from the Spanish Ministry of

  18. Automated intraoperative calibration for prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Kuiran Chen, Thomas; Heffter, Tamas; Lasso, Andras; Pinter, Csaba; Abolmaesumi, Purang; Burdette, E. Clif; Fichtinger, Gabor

    2011-01-01

    Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 ± 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 ± 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 ± 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 ± 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

  19. Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer.

    Science.gov (United States)

    Gestaut, Matthew M; Cai, Wendi; Vyas, Shilpa; Patel, Belur J; Hasan, Salman A; MunozMaldonado, Yolanda; Deb, Niloyjyoti; Swanson, Gregory

    2017-05-01

    Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Network criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression-free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (Pcryotherapy for low- and intermediate-risk groups (Pcryotherapy patients was -35°C (range, -96°C to -6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Results from this study suggest that cryotherapy is inferior to brachytherapy for patients with low- to intermediate-risk prostate cancer. Patient selection criteria for consideration of cryotherapy and brachytherapy are similar in terms of anesthesia candidacy. Therefore, cryotherapy would not be recommended as a first-line local therapy for this particular

  20. Sexual Function and the Use of Medical Devices or Drugs to Optimize Potency After Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Whaley, J. Taylor; Levy, Lawrence B.; Swanson, David A.; Pugh, Thomas J.; Kudchadker, Rajat J.; Bruno, Teresa L.; Frank, Steven J.

    2012-01-01

    Purpose: Prospective evaluation of sexual outcomes after prostate brachytherapy with iodine-125 seeds as monotherapy at a tertiary cancer care center. Methods and Materials: Subjects were 129 men with prostate cancer with I-125 seed implants (prescribed dose, 145 Gy) without supplemental hormonal or external beam radiation therapy. Sexual function, potency, and bother were prospectively assessed at baseline and at 1, 4, 8, and 12 months using validated quality-of-life self-assessment surveys. Postimplant dosimetry values, including dose to 10% of the penile bulb (D10), D20, D33, D50, D75, D90, and penile volume receiving 100% of the prescribed dose (V100) were calculated. Results: At baseline, 56% of patients recorded having optimal erections; at 1 year, 62% of patients with baseline erectile function maintained optimal potency, 58% of whom with medically prescribed sexual aids or drugs. Variables associated with pretreatment-to-posttreatment decline in potency were time after implant (p = 0.04) and age (p = 0.01). Decline in urinary function may have been related to decline in potency. At 1 year, 69% of potent patients younger than 70 years maintained optimal potency, whereas 31% of patients older than 70 maintained optimal potency (p = 0.02). Diabetes was related to a decline in potency (p = 0.05), but neither smoking nor hypertension were. For patients with optimal potency at baseline, mean sexual bother scores had declined significantly at 1 year (p < 0.01). Sexual potency, sexual function, and sexual bother scores failed to correlate with any dosimetric variable tested. Conclusions: Erections firm enough for intercourse can be achieved at 1 year after treatment, but most men will require medical aids to optimize potency. Although younger men were better able to maintain erections firm enough for intercourse than older men, there was no correlation between potency, sexual function, or sexual bother and penile bulb dosimetry.

  1. Sexual Function and the Use of Medical Devices or Drugs to Optimize Potency After Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Whaley, J. Taylor; Levy, Lawrence B. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Swanson, David A. [Department of Urology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Pugh, Thomas J. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J.; Bruno, Teresa L. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Frank, Steven J., E-mail: sjfrank@mdnaderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2012-04-01

    Purpose: Prospective evaluation of sexual outcomes after prostate brachytherapy with iodine-125 seeds as monotherapy at a tertiary cancer care center. Methods and Materials: Subjects were 129 men with prostate cancer with I-125 seed implants (prescribed dose, 145 Gy) without supplemental hormonal or external beam radiation therapy. Sexual function, potency, and bother were prospectively assessed at baseline and at 1, 4, 8, and 12 months using validated quality-of-life self-assessment surveys. Postimplant dosimetry values, including dose to 10% of the penile bulb (D10), D20, D33, D50, D75, D90, and penile volume receiving 100% of the prescribed dose (V100) were calculated. Results: At baseline, 56% of patients recorded having optimal erections; at 1 year, 62% of patients with baseline erectile function maintained optimal potency, 58% of whom with medically prescribed sexual aids or drugs. Variables associated with pretreatment-to-posttreatment decline in potency were time after implant (p = 0.04) and age (p = 0.01). Decline in urinary function may have been related to decline in potency. At 1 year, 69% of potent patients younger than 70 years maintained optimal potency, whereas 31% of patients older than 70 maintained optimal potency (p = 0.02). Diabetes was related to a decline in potency (p = 0.05), but neither smoking nor hypertension were. For patients with optimal potency at baseline, mean sexual bother scores had declined significantly at 1 year (p < 0.01). Sexual potency, sexual function, and sexual bother scores failed to correlate with any dosimetric variable tested. Conclusions: Erections firm enough for intercourse can be achieved at 1 year after treatment, but most men will require medical aids to optimize potency. Although younger men were better able to maintain erections firm enough for intercourse than older men, there was no correlation between potency, sexual function, or sexual bother and penile bulb dosimetry.

  2. Argon plasma coagulation for rectal bleeding after prostate brachytherapy

    International Nuclear Information System (INIS)

    Smith, Stephen; Wallner, Kent; Dominitz, Jason A.; Han, Ben; True, Lawrence; Sutlief, Steven; Billingsley, Kevin

    2001-01-01

    Purpose: To better define the efficacy and safety of argon plasma coagulation (APC), specifically for brachytherapy-related proctitis, we reviewed the clinical course of 7 patients treated for persistent rectal bleeding. Approximately 2-10% of prostate cancer patients treated with 125 I or 103 Pd brachytherapy will develop radiation proctitis. The optimum treatment for patients with persistent bleeding is unclear from the paucity of available data. Prior reports lack specific dosimetric information, and patients with widely divergent forms of radiation were grouped together in the analyses. Methods and Materials: Seven patients were treated with APC at the Veterans Affairs Puget Sound Health Care System and the University of Washington from 1997 to 1999 for persistent rectal bleeding due to prostate brachytherapy-related proctitis. Four patients received supplemental external beam radiation, delivered by a four-field technique. A single gastroenterologist at the Veterans Affairs Puget Sound Health Care System treated 6 of the 7 patients. If the degree of proctitis was limited, all sites of active bleeding were coagulated in symptomatic patients. An argon plasma coagulator electrosurgical system was used to administer treatments every 4-8 weeks as needed. The argon gas flow was set at 1.6 L/min, with an electrical power setting of 40-45 W. Results: The rectal V100 (the total rectal volume, including the lumen, receiving the prescription dose or greater) for the 7 patients ranged from 0.13 to 4.61 cc. Rectal bleeding was first noticed 3-18 months after implantation. APC (range 1-3 sessions) was performed 9-22 months after implantation. Five patients had complete resolution of their bleeding, usually within days of completing APC. Two patients had only partial relief from bleeding, but declined additional APC therapy. No patient developed clinically evident progressive rectal wall abnormalities after APC, (post-APC follow-up range 4-13 months). Conclusions: Most

  3. 15-Year biochemical relapse free survival in clinical Stage T1-T3 prostate cancer following combined external beam radiotherapy and brachytherapy; Seattle experience

    International Nuclear Information System (INIS)

    Sylvester, John E.; Grimm, Peter D.; Blasko, John C.; Millar, Jeremy; Orio, Peter F.; Skoglund, Scott; Galbreath, Robert W.; Merrick, Gregory

    2007-01-01

    Purpose: Long-term biochemical relapse-free survival (BRFS) rates in patients with clinical Stages T1-T3 prostate cancer continue to be scrutinized after treatment with external beam radiation therapy and brachytherapy. Methods and Materials: We report 15-year BRFS rates on 223 patients with clinically localized prostate cancer that were consecutively treated with I 125 or Pd 103 brachytherapy after 45-Gy neoadjuvant EBRT. Multivariate regression analysis was used to create a pretreatment clinical prognostic risk model using a modified American Society for Therapeutic Radiology and Oncology consensus definition (two consecutive serum prostate-specific antigen rises) as the outcome. Gleason scoring was performed by the pathologists at a community hospital. Time to biochemical failure was calculated and compared by using Kaplan-Meier plots. Results: Fifteen-year BRFS for the entire treatment group was 74%. BRFS using the Memorial Sloan-Kettering risk cohort analysis (95% confidence interval): low risk, 88%, intermediate risk 80%, and high risk 53%. Grouping by the risk classification described by D'Amico, the BRFS was: low risk 85.8%, intermediate risk 80.3%, and high risk 67.8% (p = 0.002). Conclusions: I 125 or Pd 103 brachytherapy combined with supplemental EBRT results in excellent 15-year biochemical control. Different risk group classification schemes lead to different BRFS results in the high-risk group cohorts

  4. Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    Gestaut, Matthew M.; Cai, Wendi; Vyas, Shilpa; Patel, Belur J.; Hasan, Salman A.; MunozMaldonado, Yolanda; Deb, Niloyjyoti; Swanson, Gregory

    2017-01-01

    Purpose: Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Methods and Materials: Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Network criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. Results: A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression–free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (P<.0001). The 5-year bPFS rate was 70.0% (LRC), 51.4% (IRC), 89.4% (LRB), and 89.7% (IRB). The bPFS rate was significantly different between brachytherapy and cryotherapy for low- and intermediate-risk groups (P<.05). The mean nadir temperature reached for cryotherapy patients was −35°C (range, −96°C to −6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Conclusions: Results from this study suggest that cryotherapy is inferior to brachytherapy for patients with

  5. Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gestaut, Matthew M., E-mail: Matthew.Gestaut@BSWHealth.org [Department of Radiation Oncology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States); Cai, Wendi [Department of Biostatistics, Baylor Scott and White Health, Temple, Texas (United States); Vyas, Shilpa [Department of Radiation Oncology, Swedish Cancer Institute, Seattle, Washington (United States); Patel, Belur J. [Department of Urology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States); Hasan, Salman A. [Department of Radiation Oncology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States); MunozMaldonado, Yolanda [Department of Biostatistics, Baylor Scott and White Health, Temple, Texas (United States); Deb, Niloyjyoti; Swanson, Gregory [Department of Radiation Oncology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States)

    2017-05-01

    Purpose: Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Methods and Materials: Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Network criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. Results: A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression–free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (P<.0001). The 5-year bPFS rate was 70.0% (LRC), 51.4% (IRC), 89.4% (LRB), and 89.7% (IRB). The bPFS rate was significantly different between brachytherapy and cryotherapy for low- and intermediate-risk groups (P<.05). The mean nadir temperature reached for cryotherapy patients was −35°C (range, −96°C to −6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Conclusions: Results from this study suggest that cryotherapy is inferior to brachytherapy for patients with

  6. Tri-Modality therapy with I-125 brachytherapy, external beam radiation therapy, and short- or long-term hormone therapy for high-risk localized prostate cancer (TRIP: study protocol for a phase III, multicenter, randomized, controlled trial

    Directory of Open Access Journals (Sweden)

    Konaka Hiroyuki

    2012-03-01

    Full Text Available Abstract Background Patients with high Gleason score, elevated prostate specific antigen (PSA level, and advanced clinical stage are at increased risk for both local and systemic relapse. Recent data suggests higher radiation doses decrease local recurrence and may ultimately benefit biochemical, metastasis-free and disease-specific survival. No randomized data is available on the benefits of long-term hormonal therapy (HT in these patients. A prospective study on the efficacy and safety of trimodality treatment consisting of HT, external beam radiation therapy (EBRT, and brachytherapy (BT for high-risk prostate cancer (PCa is strongly required. Methods/Design This is a phase III, multicenter, randomized controlled trial (RCT of trimodality with BT, EBRT, and HT for high-risk PCa (TRIP that will investigate the impact of adjuvant HT following BT using iodine-125 (125I-BT and supplemental EBRT with neoadjuvant and concurrent HT. Prior to the end of September 2012, a total of 340 patients with high-risk PCa will be enrolled and randomized to one of two treatment arms. These patients will be recruited from more than 41 institutions, all of which have broad experience with 125I-BT. Pathological slides will be centrally reviewed to confirm patient eligibility. The patients will commonly undergo 6-month HT with combined androgen blockade (CAB before and during 125I-BT and supplemental EBRT. Those randomly assigned to the long-term HT group will subsequently undergo 2 years of adjuvant HT with luteinizing hormone-releasing hormone agonist. All participants will be assessed at baseline and every 3 months for the first 30 months, then every 6 months until 84 months from the beginning of CAB. The primary endpoint is biochemical progression-free survival. Secondary endpoints are overall survival, clinical progression-free survival, disease-specific survival, salvage therapy non-adaptive interval, and adverse events. Discussion To our knowledge, there have

  7. SU-G-TeP1-01: A Simulation Study to Investigate Maximum Allowable Deformations of Implant Geometry Before Plan Objectives Are Violated in Prostate HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Babier, A [Department of Physics, Engineering Physics and Astronomy, Queens University, Kingston, Ontario (Canada); Joshi, C [Department of Physics, Engineering Physics and Astronomy, Queens University, Kingston, Ontario (Canada); Cancer Center of Southeastern Ontario, Kingston General Hospital, Kingston, Ontario (Canada)

    2016-06-15

    Purpose: In prostate HDR brachytherapy dose distributions are highly sensitive to changes in prostate volume and catheter displacements. We investigate the maximum deformations in implant geometry before planning objectives are violated. Methods: A typical prostate Ir-192 HDR brachytherapy reference plan was calculated on the Oncentra planning system, which used CT images from a tissue equivalent prostate phantom (CIRS Model 053S) embedded inside a pelvis wax phantom. The prostate was deformed and catheters were displaced in simulations using a code written in MATLAB. For each deformation dose distributions were calculated, based on TG43 methods, using the MATLAB code. The calculations were validated through comparison with Oncentra calculations for the reference plan, and agreed within 0.12%SD and 0.3%SD for dose and volume, respectively. Isotropic prostate volume deformations of up to +34% to −27% relative to its original volume, and longitudinal catheter displacements of 7.5 mm in superior and inferior directions were simulated. Planning objectives were based on American Brachytherapy Society guidelines for prostate and urethra volumes. A plan violated the planning objectives when less than 90% of the prostate volume received the prescribed dose or higher (V{sub 100}), or the urethral volume receiving 125% of prescribed dose or higher was more than 1 cc (U{sub 125}). Lastly, the dose homogeneity index (DHI=1-V{sub 150}/V{sub 100}) was evaluated; a plan was considered sub-optimal when the DHI fell below 0.62. Results and Conclusion: Planning objectives were violated when the prostate expanded by 10.7±0.5% or contracted by 11.0±0.2%; objectives were also violated when catheters were displaced by 4.15±0.15 mm and 3.70±0.15 mm in the superior and inferior directions, respectively. The DHI changes did not affect the plan optimality, except in the case of prostate compression. In general, catheter displacements have a significantly larger impact on plan

  8. Quantification of iodine in porous hydroxyapatite matrices for application as radioactive sources in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Kassio Andre; Lameiras, Fernando Soares [Centro de Desenvolvimento da Tecnologia Nuclear, (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Silva, Viviane Viana [Centro de Desenvolvimento da Tecnologia Nuclear, (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Universidade Vale do Rio Verde de Tres Coracoes, MG (Brazil)

    2007-07-15

    In this study, non-radioactive iodine was incorporated in two types of biodegradable hydroxyapatite-based porous matrices (HA and HACL) through impregnation process from sodium iodine aqueous solutions with varying concentrations (0.5 and 1.0 mol/L) . The results revealed that both systems presented a high capacity of incorporating iodine into their matrices. The quantity of incorporated iodine was measured through Neutron Activation Analysis (NAA). The porous ceramic matrices based on hydroxyapatite demonstrated a great potential for uses in low dose rate (LDR) brachytherapy. (author)

  9. The role of brachytherapy in the definitive management of prostate cancer; Place de la curietherapie dans le traitement du cancer prostatique localise

    Energy Technology Data Exchange (ETDEWEB)

    Crook, J. [British Columbia Cancer Agency, Center for the Southern Interior, 399, Royal Avenue, Kelowna, British Columbia, V1Y 5L33 (Canada)

    2011-06-15

    Over the past two decades, brachytherapy has played an ever expanding role in the definitive radiotherapy of prostate cancer. Brachytherapy surpasses external beam radiotherapy in its ability to deliver intense intra-prostatic dose escalation. Although initially low dose rate permanent seed brachytherapy was favored for favorable risk prostate cancers, and high dose rate temporary brachytherapy for intermediate and advanced disease, both types of brachytherapy now have a place across all the risk groups of localized prostate cancer. This article will review indications and patient selection, planning and technical aspects, toxicity and efficacy for both low and high dose rate prostate brachytherapy. (author)

  10. Evaluating the Phoenix definition of biochemical failure after (125)I prostate brachytherapy: Can PSA kinetics distinguish PSA failures from PSA bounces?

    Science.gov (United States)

    Thompson, Anna; Keyes, Mira; Pickles, Tom; Palma, David; Moravan, Veronika; Spadinger, Ingrid; Lapointe, Vincent; Morris, W James

    2010-10-01

    To evaluate the prostate-specific antigen (PSA) kinetics of PSA failure (PSAf) and PSA bounce (PSAb) after permanent (125)I prostate brachytherapy (PB). The study included 1,006 consecutive low and "low tier" intermediate-risk patients treated with (125)I PB, with a potential minimum follow-up of 4 years. Patients who met the Phoenix definition of biochemical failure (nadir + 2 ng/mL(-1)) were identified. If the PSA subsequently fell to ≤0.5 ng/mL(-1)without intervention, this was considered a PSAb. All others were scored as true PSAf. Patient, tumor and dosimetric characteristics were compared between groups using the chi-square test and analysis of variance to evaluate factors associated with PSAf or PSAb. Median follow-up was 54 months. Of the 1,006 men, 57 patients triggered the Phoenix definition of PSA failure, 32 (56%) were true PSAf, and 25 PSAb (44%). The median time to trigger nadir + 2 was 20.6 months (range, 6-36) vs. 49 mo (range, 12-83) for PSAb vs. PSAf groups (p < 0.001). The PSAb patients were significantly younger (p < 0.0001), had shorter time to reach the nadir (median 6 vs. 11.5 months, p = 0.001) and had a shorter PSA doubling time (p = 0.05). Men younger than age 70 who trigger nadir +2 PSA failure within 38 months of implant have an 80% likelihood of having PSAb and 20% chance of PSAf. With adequate follow-up, 44% of PSA failures by the Phoenix definition in our cohort were found to be benign PSA bounces. Our study reinforces the need for adequate follow-up when reporting PB PSA outcomes, to ensure accurate estimates of treatment efficacy and to avoid unnecessary secondary interventions. 2010. Published by Elsevier Inc. All rights reserved.

  11. Evaluating the Phoenix Definition of Biochemical Failure After 125I Prostate Brachytherapy: Can PSA Kinetics Distinguish PSA Failures From PSA Bounces?

    International Nuclear Information System (INIS)

    Thompson, Anna; Keyes, Mira; Pickles, Tom

    2010-01-01

    Purpose: To evaluate the prostate-specific antigen (PSA) kinetics of PSA failure (PSAf) and PSA bounce (PSAb) after permanent 125 I prostate brachytherapy (PB). Methods and Materials: The study included 1,006 consecutive low and 'low tier' intermediate-risk patients treated with 125 I PB, with a potential minimum follow-up of 4 years. Patients who met the Phoenix definition of biochemical failure (nadir + 2 ng/mL -1 ) were identified. If the PSA subsequently fell to ≤0.5 ng/mL -1 without intervention, this was considered a PSAb. All others were scored as true PSAf. Patient, tumor and dosimetric characteristics were compared between groups using the chi-square test and analysis of variance to evaluate factors associated with PSAf or PSAb. Results: Median follow-up was 54 months. Of the 1,006 men, 57 patients triggered the Phoenix definition of PSA failure, 32 (56%) were true PSAf, and 25 PSAb (44%). The median time to trigger nadir + 2 was 20.6 months (range, 6-36) vs. 49 mo (range, 12-83) for PSAb vs. PSAf groups (p < 0.001). The PSAb patients were significantly younger (p < 0.0001), had shorter time to reach the nadir (median 6 vs. 11.5 months, p = 0.001) and had a shorter PSA doubling time (p = 0.05). Men younger than age 70 who trigger nadir +2 PSA failure within 38 months of implant have an 80% likelihood of having PSAb and 20% chance of PSAf. Conclusions: With adequate follow-up, 44% of PSA failures by the Phoenix definition in our cohort were found to be benign PSA bounces. Our study reinforces the need for adequate follow-up when reporting PB PSA outcomes, to ensure accurate estimates of treatment efficacy and to avoid unnecessary secondary interventions.

  12. Use of iodine-125 brachytherapy in treatment of choroidal melanomas, technic and preliminary analysis of 78 patients

    International Nuclear Information System (INIS)

    Quetin, P.; Schumacher, C.; Schraub, S.; Meyer, L.; Polto, F.; Sahel, J.; Magnenet, P.; Andres, E.

    2001-01-01

    Purpose. - Iodine 125 curietherapy is one of the conservative treatments of uveal melanoma. The technique used to achieve these results was simplified through the physical characteristics of the radioelement and the optimized-dosimetry program employed. Patients and methods. - 78 patients with choroidal melanoma were treated with iodine 125. About 100 Gy were delivered to the superior pole of the tumour. The minimal length of follow-up was 17 months and the average, 67 months. Results. -There was 88% local control, leading to lowered visual acuity in 76 % of the cases. Radiation retinopathy, directly related to proximity to the macula, is the principle etiology. Seven patients died of hepatic metastasis, five patients were enucleated. Four patients were further treated with proton-therapy to make up for non-control locally. Conclusion. -One dose of 100 Gy to the superior pole of the tumor seemed to lead to good local control, with the exception of complications related to proximity to the macula and the optic nerve. In this attempt to optimize irradiation, the time lapse between any benefit in local control derived from irradiation and post-therapeutic complications observed remains insufficient to evaluate any relationship. (authors)

  13. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    International Nuclear Information System (INIS)

    Zhang, Wen; Yan, Zhiping; Luo, Jianjun; Fang, Zhuting; Wu, Linlin; Liu, QingXin; Qu, Xudong; Liu, Lingxiao; Wang, Jianhua

    2013-01-01

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX 2 was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan–Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 ± 0.12 kg, 57.83 ± 8.68 days, (16.73 ± 5.18 %), (29.47 ± 7.18 %), and 2.03 ± 0.13 kg, 43.67 ± 5.28 days, (63.01 ± 2.01 %), (6.02 ± 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT in rabbit model

  14. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wen; Yan, Zhiping; Luo, Jianjun; Fang, Zhuting; Wu, Linlin; Liu, QingXin; Qu, Xudong; Liu, Lingxiao; Wang, Jianhua [Fudan University, Department of Interventional Radiology, Zhongshan Hospital (China)

    2013-10-15

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT

  15. Primary Causes of Death After Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Bittner, Nathan; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Wallner, Kent E.; Allen, Zachariah A.; Brammer, Sarah G.; Moyad, Mark

    2008-01-01

    Purpose: To evaluate the primary causes of death in low-risk (low-risk), intermediate-risk (intermediate-risk), and high-risk (high-risk) patients undergoing permanent prostate brachytherapy with or without supplemental therapies. Methods and Materials: From April 1995 through November 2004, a total of 1,354 consecutive patients underwent prostate brachytherapy. All patients underwent brachytherapy >3 years before analysis. Of the patients, 532 (39.3%) received androgen deprivation therapy and 703 (51.9%) received supplemental radiation therapy. The median follow-up was 5.4 years. Multiple parameters were evaluated as predictors of cause-specific, biochemical progression-free, and overall survival. Results: The 10-year cause-specific survival was 97.0% (99.7%, 99.0%, and 90.1% for low-risk, intermediate-risk, and high-risk patients). Overall survival was 76.7% (82.5%, 78.3%, and 67.6% for low-, intermediate-, and high-risk patients, respectively). The cumulative death rate for cardiovascular disease was 11.5% (8.7%, 9.3%, and 19.8% for low-, intermediate-, and high-risk patients). The death rate from second malignancies (nonprostate cancer) was 7.2% and was not substantially different when stratified by risk group. Death from all other causes was 6.5% for the entire cohort but 1.3%, 5.0%, and 10.8% for low-, intermediate-, and high-risk patients. In multivariate analysis, death from prostate cancer was best predicted by Gleason score and risk group, whereas death from cardiovascular disease, nonprostate cancer, and all other causes were most closely related to patient age and tobacco use. Conclusions: Although cardiovascular mortality was the predominant cause of death, prostate cancer was responsible for approximately 10% of all deaths. In particular, overall survival was poorest in the high-risk group. Although high-risk patients were most likely to die of prostate cancer, the divergence in overall survival between high-risk and lower-risk patients primarily

  16. Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGETM125I brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Hayes, Joshua L.; Zhang Hualin; Sowards, Keith

    2002-01-01

    125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the ADVANTAGE TM 125 I, Model IAI-125, source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined, following the AAPM Task Group 43 recommendations. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with their 1999 standard. Measurements were performed in Solid Water TM phantom using LiF thermoluminescent dosimeters. The theoretical calculations were performed in both Solid Water TM and water using the PTRAN Monte Carlo code. The results indicated that a dose rate constant of the new source in water was 0.98±0.03 cGy h -1 U -1 . The radial dose function of the new source was measured in Solid Water TM and calculated both in water and Solid Water TM at distances up to 10.0 cm. The anisotropy function, F(r,θ), of the new source was measured and calculated in Solid Water TM at distances of 2 cm, 3 cm, 5 cm, and 7 cm and also was calculated in water at distances ranging from 1 cm to 7 cm from the source. From the anisotropy function, the anisotropy factors and anisotropy constant were derived. The anisotropy constant of the ADVANTAGE TM 125 I source in water was found to be 0.97±0.03. The dosimetric characteristics of this new source compared favorably with those from the Amersham Health Model 6711 source. Complete dosimetric parameters of the new source are presented in this paper

  17. Standardization of prostate brachytherapy treatment plans

    International Nuclear Information System (INIS)

    Ove, Roger; Wallner, Kent; Badiozamani, Kas; Korjsseon, Tammy; Sutlief, Steven

    2001-01-01

    Purpose: Whereas custom-designed plans are the norm for prostate brachytherapy, the relationship between linear prostate dimensions and volume calls into question the routine need for customized treatment planning. With the goal of streamlining the treatment-planning process, we have compared the treatment margins (TMs) achieved with one standard plan applied to patients with a wide range of prostate volumes. Methods and Materials: Preimplant transrectal ultrasound (TRUS) images of 50 unselected University of Washington patients with T1-T2 cancer and a prostate volume between 20 cc and 50 cc were studied. Patients were arbitrarily grouped into categories of 20-30 cc, 30-40 cc, and 40-50 cc. A standard 19-needle plan was devised for patients in the 30- to 40-cc range, using an arbitrary minimum margin of 5 mm around the gross tumor volume (GTV), making use of inverse planning technology to achieve 100% coverage of the target volume with accentuation of dose at the periphery and sparing of the central region. The idealized plan was applied to each patient's TRUS study. The distances (TMs) between the prostatic edge (GTV) and treated volume (TV) were determined perpendicular to the prostatic margin. Results: Averaged over the entire patient group, the ratio of thickness to width was 1.4, whereas the ratio of length to width was 1.3. These values were fairly constant over the range of volumes, emphasizing that the prostate retains its general shape as volume increases. The idealized standard plan was overlaid on the ultrasound images of the 17 patients in the 30- to 40-cc group and the V100, the percentage of target volume receiving 100% or more of the prescription dose, was 98% or greater for 15 of the 17 patients. The lateral and posterior TMs fell within a narrow range, most being within 2 mm of the idealized 5-mm TM. To estimate whether a 10-cc volume-interval stratification was reasonable, the standard plan generated from the 30- to 40-cc prostate model was

  18. In vivo dosimetry using a linear Mosfet-array dosimeter to determine the urethra dose in 125I permanent prostate implants.

    Science.gov (United States)

    Bloemen-van Gurp, Esther J; Murrer, Lars H P; Haanstra, Björk K C; van Gils, Francis C J M; Dekker, Andre L A J; Mijnheer, Ben J; Lambin, Philippe

    2009-01-01

    In vivo dosimetry during brachytherapy of the prostate with (125)I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% +/- 10.7% (1 SD). In the low-dose region outside the prostate (MOSFET detectors are suitable for in vivo dosimetry during (125)I brachytherapy of prostate cancer. An action level of +/- 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

  19. Treatment of prostate adenocarcinoma permanent implants with I 125: first experience in Uruguay

    International Nuclear Information System (INIS)

    Quarneti, A.; Clark, O.; Glaussius, A.; Kaitasoff, P.; Cosia, G.

    2010-01-01

    Full text: Objective: To report on the treatment done, toxicity and development of a group of adenocarcinoma patients with localized prostate brachytherapy implants permanent I125. Material and Methods. 37 patients were treated in the period 2001 to 2004 at the Military Hospital Central by this treatment modality. All of them were performed before implantation planning, which consisted of the volumetric calculation and calculation prostate dosimetry that included transrectal prostate ultrasound 3-5 weeks before the procedure. all patients had pathological confirmation of the lesion showed PSA values less than 11 ng / ml and Gleason score less than 7. 70% of patients received neo-adjuvant hormone therapy. In 5 patients an interactive planning system was performed computerized dosimetry, using sequential ultrasound imaging planes, allowed the dosimetric analysis before terminate the procedure and make necessary adjustments if the dose distribution did not conform. This additional dosimetric study we have not been described by other authors. Prescribed in the first 10 patients was dose 144 Gy and 160 Gy in subsequent. All patients underwent post implant CT waffle grid after 15 days of the procedure. analyzed the dose volume histogram (HDV) and D90 values??. Clinical follow-up was performed and PSA biochemical .. Preliminary Results: 33 patients were in local control without biochemical failure. Currently 4 patients presented biochemical recurrence with PSA values ??between 4 and 6 ng / ml. In neither disease was found at a distance and then raises confirmation tumor biopsy active presence will undergo surgical treatment protocols localized prostate cancer. HDV values ??D90 and are consistent with the informed by the international literature will be presented. No patient required hospitalization prolonged (greater than 24 hours) or use of higher analgesics. 2 patients had acute urinary retention (G II complication) between the tenth and twentieth day, the rest of the

  20. Experimental radiotherapy of the R1H rhabdomyosarcoma of the rat: combined use of interstitial iodine-125-brachytherapy and fractionated X-irradiation

    International Nuclear Information System (INIS)

    Doll, D.

    1995-01-01

    The study described here investigated into the therapeutic effects that split-dose x-radiation combined with interstitial iodine-125 brachytherapy would have on two different lines of the R1H rhabdomyosarcoma of the rat. The following parameters were examined: local tumour control rate; growth delay; net growth delay; position, movement and loss of seeds; tumour shape. The following results were obtained: The local tumour control rate for tumours externally treated with two seeds was by 42 Gy higher than that determined for the group treated with external irradiation alone. A procedure was developed to calculate the most appropriate distance for the seeds on the basis of tumour axes and volumes. The relationship between growth delay and mean maximum distance of the seed from the tumour margin could be ascertained on a quantitative basis. The influence of the tumour shape on the result of treatment was confirmed. Although the seeds were still active at the time of recidivation and treatment was not yet terminated, it was possible to show that the tumour bed effect, which tends to distort the growth delay calculations and may even occur in externally treated seed animals, could largely be avoided in the evaluation of this study. (orig./MG) [de

  1. Perineural invasion on prostate needle biopsy does not predict biochemical failure following brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Weight, Christopher J.; Ciezki, Jay P.; Reddy, Chandana A.; Zhou Ming; Klein, Eric A.

    2006-01-01

    Purpose: To determine if the presence of perineural invasion (PNI) predicts biochemical recurrence in patients who underwent low-dose-rate brachytherapy for the treatment of localized prostate cancer. Methods and Materials: A retrospective case control matching study was performed. The records of 651 patients treated with brachytherapy between 1996 and 2003 were reviewed. Sixty-three of these patients developed biochemical failure. These sixty-three patients were then matched in a one-to-one ratio to patients without biochemical failure, controlling for biopsy Gleason score, clinical stage, initial prostate-specific antigen, age, and the use of androgen deprivation. The pathology of the entire cohort was then reviewed for evidence of perineural invasion on initial prostate biopsy specimens. The biochemical relapse free survival rates for these two groups were compared. Results: Cases and controls were well matched, and there were no significant differences between the two groups in age, Gleason grade, clinical stage, initial prostate-specific antigen, and the use of androgen deprivation. PNI was found in 19 (17%) patients. There was no significant difference in the rates of PNI between cases and controls, 19.6% and 14.3% respectively (p 0.45). PNI did not correlate with biochemical relapse free survival (p 0.40). Conclusion: Perineural invasion is not a significant predictor of biochemical recurrence in patients undergoing brachytherapy for prostate cancer

  2. Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo method

    International Nuclear Information System (INIS)

    Oliveira, Tiago Batista de

    2016-01-01

    Expectations of the World Health Organization for the year 2030 are that the number of cancer deaths is approximately 13.2 million, reflecting the high proportion of this disease in global health issue. With respect to prostate cancer, according to the National Cancer Institute, the number of cases diagnosed worldwide in 2012 was approximately 1.1 million, while in Brazil the data demonstrated the incidence of 68,000 new cases. The treatment of cancer can be performed with surgery (prostatectomy) or radiation therapy. Among radiotherapy, we can highlight the brachytherapy technique, which consists in the introduction of small radioactive sources (seeds) within the prostate, which is delivered a high dose value in the treatment volume and low dose in the surrounding tissues. In Brazil, the medical profession estimates a demand of approximately 8000 seeds / month, and the unit cost of each seed at least US $ 26.00. The AAPM protocol TG-43 recommend the dose-rate constant, radial dose function and anisotropy function for dosimetric analysis LDR brachytherapy seeds. In this work, Monte Carlo simulations were performed in order to assess the dosimetric parameters of the OncoSeed-6711, manufactured by Oncura-GEHealthcare, and a seed developed by Radiation Technology Center, using the MCNP5 code. A 6711 seed, an IPEN seed and the 30 x 30 x 30cm 3 phantom filled with water were modeled to simulate the dose distribution. The 6711 seed parameters were compared with literature, and the results presented relative error less than 0.1% for Λ. In comparison with the 6711 seed, the IPEN model seed dosimetric parameters were similar, account the statistical uncertainty. (author)

  3. Analysis of the radiobiology of ytterbium-169 and iodine-125 permanent brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Lazarescu, G.R. [Windsor Regional Cancer Center, Ontario Cancer Treatment and Research Foundation, Windsor, Canada N8W 2X3 (Canada); Battista, J.J. [London Regional Cancer Center, Ontario Cancer Treatment and Research Foundation, Dept. of Oncology and Dept. of Medical Biophysics, University of Western Ontario, London, Canada N6A 4L6 (Canada)

    1997-09-01

    Recently, Yb-169 has been considered as a potential replacement for I-125 and Pd-103 in permanent implants. In spite of the uncertainties in the parameters necessary for an accurate radiobiological modelling, the linear quadratic model can be useful in the comparative evaluation of the radiotherapeutic merit of similar implants. In order to find out if a Yb-169 permanent implant can be made biologically 'equivalent' to an I-125 implant, we studied the dependence of local control on the tumour cell radiosensitivity and on the balance between the rate of tumour cell killing and tumour cell proliferation, for rapidly and slowly proliferating tumours. The extrapolated response dose (ERD) has been calculated for tumour and late reacting normal tissue for both types of implants and the possible biological restrictions due to the normal tissue tolerance have been discussed. Our theoretical analysis is consistent with the clinical results published for I-125 permanent implants in prostate tumours and meningiomas. It predicts that Yb-169, which has only recently been used in human tumours, can provide comparable tumour control for permanent implants in slowly proliferating tumours with an initial dose rate of 13 cGy h{sup -1}. Control might be extended to rapidly proliferating tumours by increasing the initial dose rate within a range consistent with an acceptable level of normal tissue late reaction. (author)

  4. Long term outcome and side effects in patients receiving low-dose I125 brachytherapy: a retrospective analysis

    Directory of Open Access Journals (Sweden)

    Pieter Logghe

    Full Text Available ABSTRACT Objectives: To retrospectively evaluate the disease free survival (DFS, disease specific survival (DSS,overall survival (OS and side effects in patients who received low-dose rate (LDR brachytherapy with I125 stranded seeds. Materials and methods: Between july 2003 and august 2012, 274 patients with organ confined prostate cancer were treated with permanent I125 brachytherapy. The median follow-up, age and pretreatment prostate specific antigen (iPSA was 84 months (12-120, 67 years (50-83 and 7.8 ng/mL (1.14-38, respectively. Median Gleason score was 6 (3-9. 219 patients (80% had stage cT1c, 42 patients (15.3% had stage cT2a, 3 (1.1% had stage cT2b and 3 (1.1% had stage cT2c. The median D90 was 154.3 Gy (102.7-190.2. Results: DSS was 98.5%.OS was 93.5%. 13 patients (4.7% developed systemic disease, 7 patients (2.55% had local progression. In 139 low risk patients, the 5 year biochemical freedom from failure rate (BFFF was 85% and 9 patients (6.4% developed clinical progression. In the intermediate risk group, the 5 year BFFF rate was 70% and 5 patients (7.1% developed clinical progression. Median nPSA in patients with biochemical relapse was 1.58 ng/mL (0.21 – 10.46, median nPSA in patients in remission was 0.51 ng/mL (0.01 – 8.5. Patients attaining a low PSA nadir had a significant higher BFFF (p<0.05. Median D90 in patients with biochemical relapse was 87.2 Gy (51 – 143,1. Patients receiving a high D90 had a significant higher BFFF (p<0.05. Conclusion: In a well selected patient population, LDR brachytherapy offers excellent outcomes. Reaching a low PSA nadir and attaining high D90 values are significant predictors for a higher DFS.

  5. Indication of brachytherapy of prostate with permanent implants

    International Nuclear Information System (INIS)

    Chauveinc, L.; Solignac, S.; Rosenwald, J.C.; Firmin, F.; Cosset, J.M.; Flam, T.; Thiounn, N.

    2002-01-01

    In the last decade, brachytherapy emerged as a particularly appealing new way of treating localized prostate cancer. Recently published 10-12 years biochemical control results appear to be superimposable to the best percentages achieved by surgery or conformal radiotherapy, with a small percentage of complications. This applied to severely patients. Only patients with T1/T2, PSA 60 g, hip mobility limitations, a urinary obstructive syndrome and previous trans-urethral resection lead to difficulties in technical implantation and therefore must be taken into account when discussing brachytherapy. In conclusion, for adequately selected patients, brachytherapy offers a particularly applied alternative to surgery and external radiotherapy, with satisfactory long term biochemical control rates and limited complications. (author)

  6. Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiaofeng, E-mail: xyang43@emory.edu; Rossi, Peter; Ogunleye, Tomi; Marcus, David M.; Jani, Ashesh B.; Curran, Walter J.; Liu, Tian [Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia 30322 (United States); Mao, Hui [Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia 30322 (United States)

    2014-11-01

    Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0

  7. Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

    Science.gov (United States)

    Yang, Xiaofeng; Rossi, Peter; Ogunleye, Tomi; Marcus, David M.; Jani, Ashesh B.; Mao, Hui; Curran, Walter J.; Liu, Tian

    2014-01-01

    Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0

  8. SU-E-T-259: Particle Swarm Optimization in Radial Dose Function Fitting for a Novel Iodine-125 Seed

    Energy Technology Data Exchange (ETDEWEB)

    Wu, X [University of Alabama at Birmingham, Birmingham, Al (United States); Duan, J; Popple, R; Huang, M; Shen, S; Brezovich, I [University of Alabama Birmingham, Birmingham, AL (United States); Cardan, R [UAB University of Alabama, Birmingham, Birmingham, AL (United States); Benhabib, S [University of Alabama at Birmingham, Birmingham, AL (United States)

    2014-06-01

    Purpose: To determine the coefficients of bi- and tri-exponential functions for the best fit of radial dose functions of the new iodine brachytherapy source: Iodine-125 Seed AgX-100. Methods: The particle swarm optimization (PSO) method was used to search for the coefficients of the biand tri-exponential functions that yield the best fit to data published for a few selected radial distances from the source. The coefficients were encoded into particles, and these particles move through the search space by following their local and global best-known positions. In each generation, particles were evaluated through their fitness function and their positions were changed through their velocities. This procedure was repeated until the convergence criterion was met or the maximum generation was reached. All best particles were found in less than 1,500 generations. Results: For the I-125 seed AgX-100 considered as a point source, the maximum deviation from the published data is less than 2.9% for bi-exponential fitting function and 0.2% for tri-exponential fitting function. For its line source, the maximum deviation is less than 1.1% for bi-exponential fitting function and 0.08% for tri-exponential fitting function. Conclusion: PSO is a powerful method in searching coefficients for bi-exponential and tri-exponential fitting functions. The bi- and tri-exponential models of Iodine-125 seed AgX-100 point and line sources obtained with PSO optimization provide accurate analytical forms of the radial dose function. The tri-exponential fitting function is more accurate than the bi-exponential function.

  9. The impact of body mass index on dosimetric quality in low-dose-rate prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Michelle I. Echevarria

    2016-11-01

    Full Text Available Purpose : Low-dose-rate (LDR brachytherapy has been established as an effective and safe treatment option for men with low and intermediate risk prostate cancer. In this retrospective analysis, we sought to study the effect of body mass index (BMI on post-implant dosimetric quality. Material and methods : After institutional approval, records of patients with non-metastatic prostate cancer treated in Puerto Rico with LDR brachytherapy during 2008-2013 were reviewed. All patients were implanted with 125I seeds to a prescription dose of 145 Gy. Computed tomography (CT based dosimetry was performed 1 month after implant. Patients with at least 1 year of prostate-specific antigen (PSA follow-up were included. Factors predictive of adequate D90 coverage (≥ 140 Gy were compared via the Pearson χ2 or Wilcoxon rank-sum test as appropriate. Results : One-hundred and four patients were included in this study, with 53 (51% patients having a D90 ≥ 140 Gy. The only factor associated with a dosimetric coverage detriment (D90 < 140 Gy was BMI ≥ 25 kg/m2 (p = 0.03. Prostate volume (p = 0.26, initial PSA (p = 0.236, age (p = 0.49, hormone use (p = 0.93, percent of cores positive (p = 0.95, risk group (p = 0.24, tumor stage (p = 0.66, and Gleason score (p = 0.61 did not predict D90. Conclusions : In this study we show that BMI is a significant pre-implant predictor of D90 (< 140 Gy vs. ≥ 140 Gy. Although other studies have reported that prostate volume also affects D90, our study did not find this correlation to be statistically significant, likely because all of our patients had a prostate volume 140 Gy.

  10. Applicability and dosimetric impact of ultrasound-based preplanning in high-dose-rate brachytherapy of prostate cancer

    International Nuclear Information System (INIS)

    Aebersold, D.M.; Isaak, B.; Behrensmeier, F.; Kolotas, C.; Mini, R.; Greiner, R.H.; Thalmann, G.; Kranzbuehler, H.

    2004-01-01

    Background and purpose: analyses of permanent brachytherapy seed implants of the prostate have demonstrated that the use of a preplan may lead to a considerable decrease of dosimetric implant quality. The authors aimed to determine whether the same drawbacks of preplanning also apply to high-dose-rate (HDR) brachytherapy. Patients and methods: 15 patients who underwent two separate HDR brachytherapy implants in addition to external-beam radiation therapy for advanced prostate cancer were analyzed. A pretherapeutic transrectal ultrasound was performed in all patients to generate a preplan for the first brachytherapy implant. For the second brachytherapy, a subset of patients were treated by preplans based on the ultrasound from the first brachytherapy implant. Preplans were compared with the respective postplans assessing the following parameters: coverage index, minimum target dose, homogeneity index, and dose exposure of organs at risk. The prostate geometries (volume, width, height, length) were compared as well. Results: at the first brachytherapy, the matching between the preplan and actual implant geometry was sufficient in 47% of the patients, and the preplan could be applied. The dosimetric implant quality decreased considerably: the mean coverage differed by -0.11, the mean minimum target dose by -0.15, the mean homogeneity index by -0.09. The exposure of organs at risk was not substantially altered. At the second brachytherapy, all patients could be treated by the preplan; the differences between the implant quality parameters were less pronounced. The changes of prostate geometry between preplans and postplans were considerable, the differences in volume ranging from -8.0 to 13.8 cm 3 and in dimensions (width, height, length) from -1.1 to 1.0 cm. Conclusion: preplanning in HDR brachytherapy of the prostate is associated with a substantial decrease of dosimetric implant quality, when the preplan is based on a pretherapeutic ultrasound. The implant quality

  11. Alternative Dose for Choroidal Melanoma Treated With an Iodine-125 Radioactive Plaque: A Single-Institution Retrospective Study

    International Nuclear Information System (INIS)

    Saconn, Paul A.; Gee, Christopher J.; Greven, Craig M.; McCoy, Thomas P.; Ekstrand, Kenneth E.; Greven, Kathryn M.

    2010-01-01

    Purpose: The Collaborative Ocular Melanoma Study (COMS) established iodine-125 plaque brachytherapy as an accepted standard treatment for medium-size choroidal melanoma. In the COMS, the prescription dose was 85 Gy. This is a retrospective review of our outcomes in patients treated with lower doses than those used in the COMS. Methods and Materials: From 1990 to 2004, 62 patients were treated with iodine-125 plaque brachytherapy for choroidal melanoma. COMS eye plaques were used with dose prescribed to the apex of the tumor. The median and average dose rates at the tumor apex were 63.5 cGy/h and 62.7 cGy/h, respectively. The median and average total doses were 63.0 Gy and 62.5 Gy (range, 56-69 Gy), respectively. The median and mean durations of implant were 100.0 hours and 101.1 hours (range, 71-165 hours). Results: Median follow-up time was 58.2 months. The 5-year outcomes including overall survival, disease-free survival, cause-specific survival, local failure, secondary enucleation rate, and visual acuity (VA) <20/200 were estimated using the Kaplan-Meier method. Overall, there were 7 local failures, 4 distant failures, and 10 secondary enucleations (6 due to local failure and 4 due to treatment complications). Univariate analysis was performed to identify significant prognostic factors associated with disease-free survival (baseline VA in tumor eye, tumor shape), cause-specific survival (diabetic retinopathy), local failure (none found), secondary enucleation rate (diabetic retinopathy, basal tumor dimension) and VA <20/200 (diabetic retinopathy, tumor shape, age, retinal detachment, treatment depth, and history of vision-limiting condition). Conclusions: Our survival and local control outcomes are comparable to those of the COMS. However, VA at 5 years seems to be better. Lower doses of radiation could potentially lead to better visual outcomes.

  12. Serum Testosterone Kinetics After Brachytherapy for Clinically Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Taira, Al V.; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Lief, Jonathan H.; Allen, Zachariah A.; Wallner, Kent E.

    2012-01-01

    Purpose: To evaluate temporal changes in testosterone after prostate brachytherapy and investigate the potential impact of these changes on response to treatment. Methods and Materials: Between January 2008 and March 2009, 221 consecutive patients underwent Pd-103 brachytherapy without androgen deprivation for clinically localized prostate cancer. Prebrachytherapy prostate-specific antigen (PSA) and serum testosterone were obtained for each patient. Repeat levels were obtained 3 months after brachytherapy and at least every 6 months thereafter. Multiple clinical, treatment, and dosimetric parameters were evaluated to determine an association with temporal testosterone changes. In addition, analysis was conducted to determine if there was an association between testosterone changes and treatment outcomes or the occurrence of a PSA spike. Results: There was no significant difference in serum testosterone over time after implant (p = 0.57). 29% of men experienced an increase ≥25%, 23% of men experienced a decrease ≥25%, and the remaining 48% of men had no notable change in testosterone over time. There was no difference in testosterone trends between men who received external beam radiotherapy and those who did not (p = 0.12). On multivariate analysis, preimplant testosterone was the only variable that consistently predicted for changes in testosterone over time. Men with higher than average testosterone tended to experience drop in testosterone (p < 0.001), whereas men with average or below average baseline testosterone had no significant change. There was no association between men who experienced PSA spike and testosterone temporal trends (p = 0.50) nor between initial PSA response and testosterone trends (p = 0.21). Conclusion: Prostate brachytherapy does not appear to impact serum testosterone over time. Changes in serum testosterone do not appear to be associated with PSA spike phenomena nor with initial PSA response to treatment; therefore, PSA response

  13. Serum Testosterone Kinetics After Brachytherapy for Clinically Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Taira, Al V. [Western Radiation Oncology, Mountain View, CA (United States); Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.org [Schiffler Cancer Center, Wheeling Jesuit University, Wheeling, WV (United States); Galbreath, Robert W.; Butler, Wayne M.; Lief, Jonathan H.; Allen, Zachariah A. [Schiffler Cancer Center, Wheeling Jesuit University, Wheeling, WV (United States); Wallner, Kent E. [Puget Sound Healthcare Corporation Group Health Cooperative, University of Washington, Seattle, WA (United States)

    2012-01-01

    Purpose: To evaluate temporal changes in testosterone after prostate brachytherapy and investigate the potential impact of these changes on response to treatment. Methods and Materials: Between January 2008 and March 2009, 221 consecutive patients underwent Pd-103 brachytherapy without androgen deprivation for clinically localized prostate cancer. Prebrachytherapy prostate-specific antigen (PSA) and serum testosterone were obtained for each patient. Repeat levels were obtained 3 months after brachytherapy and at least every 6 months thereafter. Multiple clinical, treatment, and dosimetric parameters were evaluated to determine an association with temporal testosterone changes. In addition, analysis was conducted to determine if there was an association between testosterone changes and treatment outcomes or the occurrence of a PSA spike. Results: There was no significant difference in serum testosterone over time after implant (p = 0.57). 29% of men experienced an increase {>=}25%, 23% of men experienced a decrease {>=}25%, and the remaining 48% of men had no notable change in testosterone over time. There was no difference in testosterone trends between men who received external beam radiotherapy and those who did not (p = 0.12). On multivariate analysis, preimplant testosterone was the only variable that consistently predicted for changes in testosterone over time. Men with higher than average testosterone tended to experience drop in testosterone (p < 0.001), whereas men with average or below average baseline testosterone had no significant change. There was no association between men who experienced PSA spike and testosterone temporal trends (p = 0.50) nor between initial PSA response and testosterone trends (p = 0.21). Conclusion: Prostate brachytherapy does not appear to impact serum testosterone over time. Changes in serum testosterone do not appear to be associated with PSA spike phenomena nor with initial PSA response to treatment; therefore, PSA response

  14. Brachytherapy for prostate cancer: Comparative characteristics of procedures

    Directory of Open Access Journals (Sweden)

    S. V. Kanaev

    2015-01-01

    Full Text Available The introduction of interstitial radiation sources is the «youngest» of the radical method of treatment of patients with prostate cancer (PC. The high level of efficiency comparable to prostatectomy at a significantly lower rate of complications causes rapid growth of clinical use of brachytherapy (BT. Depending on the radiation source and the mode of administration into the prostate gland are two types BT – high-dose rate (temporary (HDR-BT and low-dose rate (permanent (LDR-BT brachytherapy. At the heart of these two methods are based on a single principle of direct effect of the quantum gamma radiation on the area of interest. However, the differences between the characteristics of isotopes used and technical aspects of the techniques cause the difference in performance and complication rates for expression HDR-BT and LDR-BT.

  15. Body Mass Index and Prostate-Specific Antigen Failure Following Brachytherapy for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Efstathiou, Jason A.; Skowronski, Rafi Y.; Coen, John J.; Grocela, Joseph A.; Hirsch, Ariel E.; Zietman, Anthony L.

    2008-01-01

    Purpose: Increasing body mass index (BMI) is associated with prostate-specific antigen (PSA) failure after radical prostatectomy and external beam radiation therapy (EBRT). We investigated whether BMI is associated with PSA failure in men treated with brachytherapy for clinically localized prostate cancer. Patients and Methods: Retrospective analyses were conducted on 374 patients undergoing brachytherapy for stage T1c-T2cNXM0 prostate cancer from 1996-2001. Forty-nine patients (13%) received supplemental EBRT and 131 (35%) received androgen deprivation therapy (ADT). Height and weight data were available for 353 (94%). Cox regression analyses were performed to evaluate the relationship between BMI and PSA failure (nadir + 2 ng/ml definition). Covariates included age, race, preimplantation PSA, Gleason score, T category, percent of prescription dose to 90% of the prostate, use of supplemental EBRT, and ADT. Results: Median age, PSA, and BMI were 66 years (range, 42-80 years), 5.7 ng/ml (range, 0.4-22.6 ng/ml), and 27.1 kg/m 2 (range, 18.2-53.6 kg/m 2 ), respectively. After a median follow-up of 6.0 years (range, 3.0-10.2 years), there were 76 PSA recurrences. The BMI was not associated with PSA failure. Six-year PSA failure rates were 30.2% for men with BMI less than 25 kg/m 2 , 19.5% for BMI of 25 or greater to less than 30 kg/m 2 , and 14.4% for BMI of 30 kg/m 2 or greater (p = 0.19). Results were similar when BMI was analyzed as a continuous variable, using alternative definitions of PSA failure, and excluding patients treated with EBRT and/or ADT. In multivariate analyses, only baseline PSA was significantly associated with shorter time to PSA failure (adjusted hazard ratio, 1.12; 95% confidence interval, 1.05-1.20; p 0.0006). Conclusions: Unlike after surgery or EBRT, BMI is not associated with PSA failure in men treated with brachytherapy for prostate cancer. This raises the possibility that brachytherapy may be a preferred treatment strategy in obese

  16. Dosimetric Coverage of the Prostate, Normal Tissue Sparing, and Acute Toxicity with High-Dose-Rate Brachytherapy for Large Prostate Volumes

    Directory of Open Access Journals (Sweden)

    George Yang

    2015-06-01

    Full Text Available ABSTRACTPurposeTo evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes.Materials and MethodsOne hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL were treated with high-dose-rate (HDR brachytherapy ± intensity modulated radiation therapy (IMRT to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38% unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE version 4.ResultsMedian follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3% patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17% patients developed Grade 2 acute urinary retention. American Urological Association (AUA symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p=0.04. There was no ≥ Grade 3 acute toxicity.ConclusionsDosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes.

  17. Dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with high-dose-rate brachytherapy for large prostate volumes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, George; Strom, Tobin J.; Shrinath, Kushagra; Mellon, Eric A.; Fernandez, Daniel C.; Biagioli, Matthew C. [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Wilder, Richard B., E-mail: mcbiagioli@yahoo.com [Cancer Treatment Centers of America, Newnan, GA (United States)

    2015-05-15

    Purpose: to evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes. Materials and methods: one hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL) were treated with high-dose-rate (HDR) brachytherapy ± intensity modulated radiation therapy (IMRT) to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38%) unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4. Results: median follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3%) patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17%) patients developed Grade 2 acute urinary retention. American Urological Association (AUA) symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p-0.04). There was no ≥ Grade 3 acute toxicity. Conclusions: dosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes. (author)

  18. Perineal recurrence of prostate cancer six years after trans-perineal brachytherapy

    NARCIS (Netherlands)

    Eppinga, Wietse; Vijverberg, Peter; Moerland, Rien; Brand, Eric; van der Voort van Zyp, Jochem; Noteboom, Juus; van Vulpen, Marco

    We report a case of perineal recurrence of prostate cancer 6 years after low-dose-rate (LDR) brachytherapy for localized prostate cancer. The most common approach to treat such perineal masses, including those occurring after prior biopsy or surgery, is local excision. We report the use of

  19. Prostate-specific antigen bounce after high-dose rate brachytherapy with external beam radiation therapy for prostate cancer patients

    International Nuclear Information System (INIS)

    Sakamoto, Naotaka; Kakinoki, Hiroaki; Tsutsui, Akio; Yoshikawa, Masahiro; Iguchi, Atsushi; Matsunobu, Toru; Uehara, Satoru

    2008-01-01

    Prostate-specific antigen (PSA) bounce after high-dose rate (HDR) brachytherapy with external beam radiation therapy (EBRT) for prostate cancer patients was evaluated. Sixty-one patients treated with HDR-brachytherapy followed by EBRT had a minimum follow-up of 12 months (median, 24 months) in our institute. A PSA bounce was defined as a rise of at least 0.1 ng/ml greater than a previous PSA level, with a subsequent decline equal to, or less than, the initial nadir. A PSA bounce was noted in 16 (26.2%) of 61 patients (one patient had a PSA bounce twice). Median time to develop a PSA bounce was 18 months, but 23.5% developed a PSA bounce after 24 months. Median duration of PSA bounce was 6 months and 11.8% had increased PSA within a period of 12 months. Median bounce height was 0.2 ng/ml (range, 0.1 to 3.39 ng/ml). A bounce height of gerater than 2 ng/ml was seen in 11.8%. Clinical characteristics (age, prostate volume, neoadjuvant endocrine therapy, risk classification, stage, pretreatment PSA, Gleason score) do not predict whether or not there will be a PSA bounce. In patients treated with HDR-brachytherapy followed by EBRT, the incidence and characteristics of PSA bounce were similar to those in patients treated with low-dose rate brachytherapy. Physicians should be aware of the possibility of PSA bounce following HDR-brachytherapy with EBRT. (author)

  20. A review of the recommendations governing quality assurance of ultrasound systems used for guidance in prostate brachytherapy.

    Science.gov (United States)

    Doyle, Andrea Jane; King, Deirdre M; Browne, Jacinta E

    2017-12-01

    Ultrasound guided brachytherapy for the treatment of prostate cancer has become a routine treatment option, due to many benefits including patient recovery and dose localisation [1]; however it is not clear whether the standards which govern the image quality for these systems are adequate. Upon review of the recommended standards for ultrasound systems used in prostate brachytherapy procedures, the recommended tests do not appear to be specific to the clinical application of ultrasound guided prostate brachytherapy. Rather they are generic and similar to those recommended for other clinical applications such as general abdominal scanning [2]. Furthermore, there is growing evidence that these tests should be specific to the clinical application [3,4] in order to gain meaningful data about the performance of the system for the application, and also to detect clinically relevant changes in quality control results. An additional problem is that there are no clinically relevant test phantom recommended for the quality assurance of ultrasound systems used in prostate brachytherapy. The image quality for this application of ultrasound needs to be monitored to ensure consistent levels of confidence in the procedure. This paper reviews the currently recommended test guidelines and test phantoms for ultrasound systems used in prostate brachytherapy from the different standard bodies and professional organisations. A critical analysis of those tests which are most reflective of the imaging and guidance tasks undertaken in an ultrasound guided prostate brachytherapy procedure will also be presented to inform the design of a TRUS quality assurance protocol. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Prostate Brachytherapy Case Volumes by Academic and Nonacademic Practices: Implications for Future Residency Training

    International Nuclear Information System (INIS)

    Orio, Peter F.; Nguyen, Paul L.; Buzurovic, Ivan; Cail, Daniel W.; Chen, Yu-Wei

    2016-01-01

    Purpose: The use of prostate brachytherapy has continued to decline in the United States. We examined the national practice patterns of both academic and nonacademic practices performing prostate brachytherapy by case volume per year to further characterize the decline and postulate the effect this trend might have on training the next generation of residents. Methods and Materials: Men diagnosed with prostate cancer who had undergone radiation therapy in 2004 to 2012 were identified. The annual brachytherapy case volume at each facility was determined and further categorized into ≤12 cases per year (ie, an average of ≤1 cases per month), 13 to 52 cases per year, and ≥53 cases per year (ie, an average of ≥1 cases per week) in academic practices versus nonacademic practices. Results: In 2004 to 2012, academic practices performing an average of ≤1 brachytherapy cases per month increased from 56.4% to 73.7%. In nonacademic practices, this percentage increased from 60.2% to 77.4% (P<.0001 for both). Practices performing an average of ≥1 cases per week decreased among both academic practices (from 6.7% to 1.5%) and nonacademic practices (from 4.5% to 2.7%). Conclusions: Both academic and nonacademic radiation oncology practices have demonstrated a significant reduction in the use of prostate brachytherapy from 2004 to 2012. With the case volume continuing to decline, it is unclear whether we are prepared to train the next generation of residents in this critical modality.

  2. Protocol-based image-guided salvage brachytherapy. Early results in patients with local failure of prostate cancer after radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lahmer, G.; Lotter, M.; Kreppner, S.; Fietkau, R.; Strnad, V. [University Hospital Erlangen (Germany). Dept. of Radiation Oncology

    2013-08-15

    Purpose: To assess the overall clinical outcome of protocol-based image-guided salvage pulsed-dose-rate brachytherapy for locally recurrent prostate cancer after radiotherapy failure particularly regarding feasibility and side effects. Patients and methods: Eighteen consecutive patients with locally recurrent prostate cancer (median age, 69 years) were treated during 2005-2011 with interstitial PDR brachytherapy (PDR-BT) as salvage brachytherapy after radiotherapy failure. The treatment schedule was PDR-BT two times with 30 Gy (pulse dose 0.6 Gy/h, 24 h per day) corresponding to a total dose of 60 Gy. Dose volume adaptation was performed with the aim of optimal coverage of the whole prostate (V{sub 100} > 95 %) simultaneously respecting the protocol-based dose volume constraints for the urethra (D{sub 0.1} {sub cc} < 130 %) and the rectum (D{sub 2} {sub cc} < 50-60 %) taking into account the previous radiation therapy. Local relapse after radiotherapy (external beam irradiation, brachytherapy with J-125 seeds or combination) was confirmed mostly via choline-PET and increased PSA levels. The primary endpoint was treatment-related late toxicities - particularly proctitis, anal incontinence, cystitis, urinary incontinence, urinary frequency/urgency, and urinary retention according to the Common Toxicity Criteria. The secondary endpoint was PSA-recurrence-free survival. Results: We registered urinary toxicities only. Grade 2 and grade 3 toxicities were observed in up to 11.1 % (2/18) and 16.7 % (3/18) of patients, respectively. The most frequent late-event grade 3 toxicity was urinary retention in 17 % (3/18) of patients. No late gastrointestinal side effects occurred. The biochemical PSA-recurrence-free survival probability at 3 years was 57.1 %. The overall survival at 3 years was 88.9 %; 22 % (4/18) of patients developed metastases. The median follow-up time for all patients after salvage BT was 21 months (range, 8-77 months). Conclusion: Salvage PDR-brachytherapy

  3. Clinical application of permanent implantation of iodine 125 seeds for osseous metastases

    International Nuclear Information System (INIS)

    Li Jinxin; Zhang Qizhou; Li Guoliang

    2010-01-01

    Objective: To evaluate the clinical efficacy of permanent implantation of iodine 125 seeds in the treatment of osseous metastases. Methods: Radioactive iodine 125 seeds were implanted permanently in 32 lesions of 25 patients with osseous metastases of different origins. The ostalgia-relieving degree and the imaging alterations of the osseous metastasis lesions were observed. Results: The effective pain-relieving rate was 92% caused by permanent implantation of iodine 125 seeds. Of al 1 the patients, 15 patients achieved complete response, 8 patients obtained partial response (PR), and 2 patients had no change. The pain grade was decreased significantly after the treatment (P 125 I seeds has a definite effect on tumor metastasis and caused minimal damage and few complications. It is worthy of popularization in clinic. (authors)

  4. Quality asurance of iodinated (125 I) human fibrinogen

    International Nuclear Information System (INIS)

    Vines, E.J.

    1980-05-01

    The radiopharmaceutical iodinated ( 125 I) human fibrinogen is currently used for the detection of deep vein thrombosis in the legs, a fairly common post-surgical complication. A comprehensive quality assurance programme for ( 125 I) - human fibrinogen has been determined for routine use at the Australian Radiation Laboratory, with adaptions necessary for hospital quality control testing

  5. Three-dimensional computed tomography-guided monotherapeutic pararectal brachytherapy of prostate cancer with seminal vesicle invasion

    International Nuclear Information System (INIS)

    Koutrouvelis, Panos; Lailas, Niko; Hendricks, Fred; Gil-Montero, Guillermo; Sehn, James; Katz, Stuart

    2001-01-01

    Purpose: To treat patients with prostate cancer and seminal vesicle invasion with monotherapeutic three dimensional computed tomography (3-DCT)-guided posterior pararectal brachytherapy. Methods and materials: Three hundred and sixty two patients with clinical stage T1 a,b or T2 a,b of prostate cancer were referred for 3-DCT-guided brachytherapy. Each underwent further staging with 3-D CT-guided pararectal biopsy of the seminal vesicles under local anesthesia during the pre-treatment CT-planning. Forty-three patients (12%) were upstaged to T3 cNoMo disease. In the set of 43 patients, Eight had Gleason's score≤6, 24 Gleason's score=7, and 11 patients ≥8. Initial PSA was 20 in 18 patients. Of the 43 patients, 37 patients were treated monotherapeutically with 3-D CT-guided brachytherapy. No patients received hormone therapy after the implant. The prescribed dosage to the seminal vesicles and prostate is 120 Gy with Pd-103 seeds and 144 Gy with 1-125 seeds. Results: The prescribed dosage was achieved in all 37 patient's throughout the seminal vesicles whose range of target radiation extended 5-10 mm outside the target in the adjacent fat as calculated with post-implant CT-dosimetry with Varian Brachy Vision or MMS software. Prostate Specific Antigen (PSA) outcome data were available in 34 patients treated with monotherapy and follow up ranged from 12-56 months (median, 24 months). Decreased PSA levels were stratified into six groups based on the presenting Gleason's score and initial PSA. In the first group (with Gleason's score≤6 and initial PSA 20 ng/ml), PSA decreased to less than 0.5 ng/ml in four out of eight patients (50%). All of the patients in the fourth group (with Gleason's score≥8 and initial PSA 20 ng/ml). There were no patients with Gleason's score of 1-6 and greater than 20 ng/ml initial PSA. Patients, irrespective of the Gleason's score and PSA, had an overall response of decreased PSA (less than 1 ng/ml) of 79%. Conclusion: 3-D CT

  6. Prostate-specific antigen density is predictive of outcome in suboptimal prostate seed brachytherapy.

    Science.gov (United States)

    Benzaquen, David; Delouya, Guila; Ménard, Cynthia; Barkati, Maroie; Taussky, Daniel

    In prostate seed brachytherapy, a D 90 of prostate-specific antigen + 2). Univariate and multivariate analyses were performed, adjusting for known prognostic factors such as D 90 and prostate-specific antigen density (PSAD) of ≥0.15 ng/mL/cm 3 , to evaluate their ability to predict BF. Median followup for patients without BF was 72 months (interquartile range 56-96). BF-free recurrence rate at 5 years was 95% and at 8 years 88%. In univariate analysis, PSAD and cancer of the prostate risk assessment score were predictive of BF. On multivariate analysis, none of the factors remained significant. The best prognosis had patients with a low PSAD (<0.15 ng/mL/cm 3 ) and an optimal implant at 30 days after implantation (as defined by D 90  ≥ 130 Gy) compared to patients with both factors unfavorable (p = 0.006). A favorable PSAD was associate with a good prognosis, independently of the D 90 (<130 Gy vs. ≥130 Gy, p = 0.7). Patients with a PSAD of <0.15 ng/mL/cm 3 have little risk of BF, even in the case of a suboptimal implant. These results need to be validated in other patients' cohorts. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  7. Permanent interstitial low-dose-rate brachytherapy for patients with low risk prostate cancer. An interim analysis of 312 cases

    Energy Technology Data Exchange (ETDEWEB)

    Badakhshi, Harun; Graf, Reinhold; Budach, Volker; Wust, Peter [University Hospital Berlin, Department for Radiation Oncology of Charite School of Medicine, Berlin (Germany)

    2015-04-01

    The biochemical relapse-free survival (bRFS) rate after treatment with permanent iodine-125 seed implantation (PSI) or combined seeds and external beam radiotherapy (COMB) for clinical stage T1-T2 localized prostate cancer is a clinically relevant endpoint. The goal of this work was to evaluate the influence of relevant patient- and treatment-related factors. The study population comprised 312 consecutive patients treated with permanent seed implantation. All patients were evaluable for analysis of overall survival (OS) and disease-specific survival (DSS), 230 for bRFS, of which 192 were in the PSI group and 38 in the COMB group. The prescribed minimum peripheral dose was 145 Gy for PSI, for COMB 110 Gy implant and external beam radiotherapy of 45 Gy. The median follow-up time was 33 months (range 8-66 months). bRFS was defined as a serum prostate-specific antigen (PSA) level ≤ 0.2 ng/ml at last follow-up. Overall, the actuarial bRFS at 50 months was 88.4 %. The 50-month bRFS rate for PSI and COMB was 90.9 %, and 77.2 %, respectively. In the univariate analysis, age in the categories ≤ 63 and > 63 years (p < 0.00), PSA nadir (≤ 0.5 ng/ml and > 0.5 ng/ml) and PSA bounce (yes/no) were the significant predicting factors for bRFS. None of the other patient and treatment variables (treatment modality, stage, PSA, Gleason score, risk group, number of risk factors, D90 and various other dose parameters) were found to be a statistically significant predictor of 50-month bRFS. The biochemical failure rates were low in this study. As a proof of principle, our large monocenteric analysis shows that low-dose-rate brachytherapy is an effective and safe procedure for patients with early stage prostate cancer. (orig.) [German] Das biochemisch rezidivfreie Ueberleben (bRFS) nach der Brachytherapie mit permanenter Iod-125-Seed-Implantation (PSI) oder in Kombination mit externer Radiotherapie (COMB) ist beim Patienten mit fruehem Prostatakarzinom (T1/T2) ein relevanter

  8. Iodine-125 radiation of posterior uveal melanoma

    International Nuclear Information System (INIS)

    Packer, S.

    1987-01-01

    Twenty-eight cases of posterior choroidal melanoma were treated with iodine-125 in gold eye plaques. Eleven cases were located within 3.0 mm of the optic nerve (group A), nine were within 3.0 mm of the fovea (group B), and eight were within 3.0 mm of the optic nerve and fovea (group C). The mean follow-up of group A was 46.3 months; group B, 25.5 months; and group C, 42.7 months. Complications included macular edema, cataract and tumor growth. Visual acuity remained within two lines of that tested preoperatively for 4 of 11 patients in group A, 4 of 9 in group B, and 5 of 8 in group C. These results with iodine-125 suggest it as an appropriate treatment for patients with choroidal melanoma located near optic nerve and/or macula

  9. Iodine-125 radiation of posterior uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Packer, S.

    1987-12-01

    Twenty-eight cases of posterior choroidal melanoma were treated with iodine-125 in gold eye plaques. Eleven cases were located within 3.0 mm of the optic nerve (group A), nine were within 3.0 mm of the fovea (group B), and eight were within 3.0 mm of the optic nerve and fovea (group C). The mean follow-up of group A was 46.3 months; group B, 25.5 months; and group C, 42.7 months. Complications included macular edema, cataract and tumor growth. Visual acuity remained within two lines of that tested preoperatively for 4 of 11 patients in group A, 4 of 9 in group B, and 5 of 8 in group C. These results with iodine-125 suggest it as an appropriate treatment for patients with choroidal melanoma located near optic nerve and/or macula.

  10. A gEUD-based inverse planning technique for HDR prostate brachytherapy: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Giantsoudi, D. [Department of Radiological Sciences, University of Texas Health Sciences Center, San Antonio, Texas 78229 (United States); Department of Radiation Oncology, Francis H. Burr Proton Therapy Center, Boston, Massachusetts 02114 (United States); Baltas, D. [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach GmbH, 63069 Offenbach (Germany); Nuclear and Particle Physics Section, Physics Department, University of Athens, 15701 Athens (Greece); Karabis, A. [Pi-Medical Ltd., Athens 10676 (Greece); Mavroidis, P. [Department of Radiological Sciences, University of Texas Health Sciences Center, San Antonio, Texas 78299 and Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, 17176 (Sweden); Zamboglou, N.; Tselis, N. [Strahlenklinik, Klinikum Offenbach GmbH, 63069 Offenbach (Germany); Shi, C. [St. Vincent' s Medical Center, 2800 Main Street, Bridgeport, Connecticut 06606 (United States); Papanikolaou, N. [Department of Radiological Sciences, University of Texas Health Sciences Center, San Antonio, Texas 78299 (United States)

    2013-04-15

    Purpose: The purpose of this work was to study the feasibility of a new inverse planning technique based on the generalized equivalent uniform dose for image-guided high dose rate (HDR) prostate cancer brachytherapy in comparison to conventional dose-volume based optimization. Methods: The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO (Hybrid Inverse Planning Optimization) is compared with alternative plans, which were produced through inverse planning using the generalized equivalent uniform dose (gEUD). All the common dose-volume indices for the prostate and the organs at risk were considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by comparing dose volume histogram and gEUD evaluators. Results: Our results demonstrate the feasibility of gEUD-based inverse planning in HDR brachytherapy implants for prostate. A statistically significant decrease in D{sub 10} or/and final gEUD values for the organs at risk (urethra, bladder, and rectum) was found while improving dose homogeneity or dose conformity of the target volume. Conclusions: Following the promising results of gEUD-based optimization in intensity modulated radiation therapy treatment optimization, as reported in the literature, the implementation of a similar model in HDR brachytherapy treatment plan optimization is suggested by this study. The potential of improved sparing of organs at risk was shown for various gEUD-based optimization parameter protocols, which indicates the ability of this method to adapt to the user's preferences.

  11. Fully automated MRI-guided robotics for prostate brachytherapy

    International Nuclear Information System (INIS)

    Stoianovici, D.; Vigaru, B.; Petrisor, D.; Muntener, M.; Patriciu, A.; Song, D.

    2008-01-01

    The uncertainties encountered in the deployment of brachytherapy seeds are related to the commonly used ultrasound imager and the basic instrumentation used for the implant. An alternative solution is under development in which a fully automated robot is used to place the seeds according to the dosimetry plan under direct MRI-guidance. Incorporation of MRI-guidance creates potential for physiological and molecular image-guided therapies. Moreover, MRI-guided brachytherapy is also enabling for re-estimating dosimetry during the procedure, because with the MRI the seeds already implanted can be localised. An MRI compatible robot (MrBot) was developed. The robot is designed for transperineal percutaneous prostate interventions, and customised for fully automated MRI-guided brachytherapy. With different end-effectors, the robot applies to other image-guided interventions of the prostate. The robot is constructed of non-magnetic and dielectric materials and is electricity free using pneumatic actuation and optic sensing. A new motor (PneuStep) was purposely developed to set this robot in motion. The robot fits alongside the patient in closed-bore MRI scanners. It is able to stay fully operational during MR imaging without deteriorating the quality of the scan. In vitro, cadaver, and animal tests showed millimetre needle targeting accuracy, and very precise seed placement. The robot tested without any interference up to 7T. The robot is the first fully automated robot to function in MRI scanners. Its first application is MRI-guided seed brachytherapy. It is capable of automated, highly accurate needle placement. Extensive testing is in progress prior to clinical trials. Preliminary results show that the robot may become a useful image-guided intervention instrument. (author)

  12. The brachytherapy with low dose-rate iridium for prostate cancer

    International Nuclear Information System (INIS)

    Momma, Tetsuo; Saito, Shiro; Ohki, Takahiro; Satoh, Hiroyuki; Toya, Kazuhito; Dokiya, Takushi; Murai, Masaru

    2000-01-01

    Brachytherapy as an option for the treatment of prostate cancer has been commonly performed in USA. As the permanent seeding of the radioactive materials is strictly restricted by the law in Japan, brachytherapy must be performed by the temporary implant. This treatment has been performed at a few facilities in Japan mostly using high dose-rate iridium. Only our facility has been using low dose-rate iridium (LDR-Ir) for prostate cancer. This study evaluates the clinical results of the treatment. Since December 1997 to December 1999, 26 patients with histologically diagnosed as prostate cancer (Stage B, 92%; Stage C, 8%) underwent brachytherapy. Twenty-two patients received brachytherapy alone, three were treated with a combination of brachytherapy and external beam radiotherapy (ERT) and one was treated with a combination of brachytherapy and neoadjuvant endocrine therapy. Patients ranged in age from 61 to 84 (median 76) years old. Treatment was initiated with perineal needle placement. From 10 to 14 needles were placed through the holes on the template which was fixed to the stabilizer of the transrectal ultrasound probe. After the needle placement, CT scan was performed to draw distribution curves for the treatment planning. LDR-Ir wires were introduced to the sheath and indwelled during the time calculated from dosimetry. Peripheral dose was 70 Gy for the monotherapy of brachytherapy. For the combination therapy, 40 Gy was given by brachytherapy and 36 Gy with ERT afterwards. LDR-Ir wires were removed after completion of the radiation and patients were followed with serum PSA level and annual biopsy. During 2 to 26 (median 12) months follow-up, 8 out of 9 patients with initial PSA level above 20 ng/ml showed PSA failure. All 13 patients with initial PSA level lower than 20 ng/ml were free from PSA failure. Eight out of 11 patients with Gleason's score 7 or higher showed PSA failure, and all 14 patients (including three patients with combined therapy) with

  13. Comparative studies on permanent prostate brachytherapy: pre-plan and real-time transrectal ultrasound guided iodine-125 seed implants at Korle-Bu Teaching Hospital, Ghana

    International Nuclear Information System (INIS)

    Kalolo, L.T.

    2013-06-01

    This research was carried out to investigate and compare the real-time and pre-plan implant at the Radiotherapy Department of the Korle Bu Teaching Hospital, Ghana. Prowess Panther 4.5 treatment planning system and variseed 7.2 software were used for pre-plan and real-time implant respectively. The study was conducted for eighty three (83) patients treated for prostate cancer through real-time implant brachytherapy between september, 2008 to April, 2013. Thirty one patients (31) patients whose ultrasound images were available were selected for the pre-plan study. The slices of ultrasound images were re-drawn on transparent A-4 sheets and later on scanned, contoured and registered in the treatment planning system (prowess 4.5). After planning, the volume to be implanted, total number of needles, seeds and the total activity of the source were displayed. Comparison was done withe the pre-plan and real-time implant. In both cases the variation was below 5% as recommended in dosimetry. About 30% - 40% of the imported seeds were left un-used due to over-estimation of seeds ordered from the manufacturer (BARD Company-USA). Hence this work (pre-plan) aims to solve this problem. The comparison for dosimetric parameters was assessed for prostate, urethra and rectum as (V 95%, V 100%, V 150%, D90Gy, D90%), (D90Gy, D90%, D30Gy, D30% ) and (V 100%, D30Gy and D30%) respectively and the variation were within the limit of ± 5%. Comparison of dosimetric values for this work were done with other institutions, like Karolinska university hospital, Sweden, The institute of Curie/ hospital Cochin Group Paris-France and European recommendations. The values reported at Korle - Bu teaching hospital (this work) were in good agreement with the international guidelines. (au)

  14. Dosimetry on ocular brachytherapy with I-125 ophthalmologic ROPES and COMS plaques

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Campos, Tarcisio P.R.

    2009-01-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departuring absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational voxel model and an analytical model were coupled, including the heterogeneous properties of the globe and the adjacent tissues. The analytical model was applied to define the thin structures of the ocular globe. This computational model is used to simulate orbital irradiation with ROPES and COMS ophthalmologic plaques placed on the sclera surface filled to ten and eight iodine-125 seeds, respectively. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The external globe structures receive 0.5% of the maximum internal dose. The crystalline lens dosimetry depends on the position and thickness of the tumor and the plaque diameters. On the present case, 12.75% of maximum dose is found on the lens. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy, incorporating anthropomorphic and anthropometric features of the real eyeball. (author)

  15. Dosimetry on ocular brachytherapy with I-125 ophthalmologic ROPES and COMS plaques

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnoloica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar], e-mail: aprata@des.cefetmg.br; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares], e-mail: campos@nuclear.ufmg.br

    2009-07-01

    Radiotherapy is an alternative to ocular enucleation. However, the irradiation of ocular region can bring deleterious effects due to the high doses, mainly in the lens, retina and in the bone structures in growth phase. Brachytherapy instead of teletherapy looks for departuring absorbed doses in tumor minimizing doses in the lens and the adjacent tissues of the eyeball (orbital region), avoiding deleterious effects. Thus, a three-dimensional computational voxel model and an analytical model were coupled, including the heterogeneous properties of the globe and the adjacent tissues. The analytical model was applied to define the thin structures of the ocular globe. This computational model is used to simulate orbital irradiation with ROPES and COMS ophthalmologic plaques placed on the sclera surface filled to ten and eight iodine-125 seeds, respectively. Simulations are performed on the MCNP5 code. The computational simulation allows evaluating how the dose rates are spatially distributed in the orbital volume. The results are normalized to 100% at the maximum dose on the tumor base, and by the applied source activity. The external globe structures receive 0.5% of the maximum internal dose. The crystalline lens dosimetry depends on the position and thickness of the tumor and the plaque diameters. On the present case, 12.75% of maximum dose is found on the lens. The maximum dose is found onto the eyeball, in the vitreous. The present model represents an advance in simulating and predicting absorbed dose on ocular brachytherapy, incorporating anthropomorphic and anthropometric features of the real eyeball. (author)

  16. A survey of current clinical practice in permanent and temporary prostate brachytherapy: 2010 update.

    Science.gov (United States)

    Buyyounouski, Mark K; Davis, Brian J; Prestidge, Bradley R; Shanahan, Thomas G; Stock, Richard G; Grimm, Peter D; Demanes, D Jeffrey; Zaider, Marco; Horwitz, Eric M

    2012-01-01

    To help establish patterns of care and standards of care of interstitial permanent low-dose-rate (LDR) and temporary high-dose-rate brachytherapy for prostate cancer and to compare the results with a similar 1998 American Brachytherapy Society (ABS) survey. A comprehensive questionnaire intended to survey specific details of current clinical brachytherapy practice was provided to the participants of the seventh ABS Prostate Brachytherapy School. Responses were tabulated and descriptive statistics are reported. Sixty-five brachytherapy practitioners responded to the survey. Eighty-nine percent (89%) of respondents performed LDR and 49% perform high-dose-rate brachytherapy. The median number of years of experience for LDR brachytherapists increased from 5 to 10 years over the course of the 12 years since the preceding survey. Compared with the first ABS, a smaller proportion of respondents received formal brachytherapy residency training (43% vs. 56%) or formal "hands-on" brachytherapy training (15% vs. 63%). There has been a marked decline in the utilization of the Mick applicator (Mick Radio-Nuclear Instruments, Inc., Mount Vernon, NY, USA) (60% vs. 28%) and an increase in the use of stranded seeds (40% vs. 11%). Compliance with postimplant dosimetry was higher in the 2010 survey. This survey does suggest an evolution in the practice of LDR brachytherapy since 1998 and aids in identifying aspects that require further progress or investigation. ABS guidelines and other practice recommendations appear to impact the practice of brachytherapy. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. Enzymatic iodination of salivary proteins by the 125I-lactoperoxidase system

    International Nuclear Information System (INIS)

    Tenovuo, J.; Sarimo, S.S.

    1977-01-01

    Purified milk lactoperoxidase and endogenous human salivary peroxidase were used to label the proteins of whole mouth saliva with [ 125 I]iodide. The proteins were then analyzed by isoelectric focusing or they were subjected to one-dimensional polyacrylamide gel electrophoresis at pH 8.4. The radioactivity of the resolved protein fractions was determined. There were three to four major and four to five minor areas of radioactivity which were carried together with more or less distinctive fractions. Amylase and albumin were shown to be the most effective in binding [ 125 I]iodide. No significant differences were observed in the iodination patterns of salivary proteins iodinated in the presence of endogenous saliva peroxidase and those iodinated in the presence of added milk lactoperoxidase. Hydrogen peroxide was necessary for iodination to take place. The significance of iodoproteins and the role of salivary peroxidases in the nonthyroidal metabolism of iodine are discussed. (author)

  18. Dose reduction in LDR brachytherapy by implanted prostate gold fiducial markers.

    Science.gov (United States)

    Landry, Guillaume; Reniers, Brigitte; Lutgens, Ludy; Murrer, Lars; Afsharpour, Hossein; de Haas-Kock, Danielle; Visser, Peter; van Gils, Francis; Verhaegen, Frank

    2012-03-01

    The dosimetric impact of gold fiducial markers (FM) implanted prior to external beam radiotherapy of prostate cancer on low dose rate (LDR) brachytherapy seed implants performed in the context of combined therapy was investigated. A virtual water phantom was designed containing a single FM. Single and multi source scenarios were investigated by performing Monte Carlo dose calculations, along with the influence of varying orientation and distance of the FM with respect to the sources. Three prostate cancer patients treated with LDR brachytherapy for a recurrence following external beam radiotherapy with implanted FM were studied as surrogate cases to combined therapy. FM and brachytherapy seeds were identified on post implant CT scans and Monte Carlo dose calculations were performed with and without FM. The dosimetric impact of the FM was evaluated by quantifying the amplitude of dose shadows and the volume of cold spots. D(90) was reported based on the post implant CT prostate contour. Large shadows are observed in the single source-FM scenarios. As expected from geometric considerations, the shadows are dependent on source-FM distance and orientation. Large dose reductions are observed at the distal side of FM, while at the proximal side a dose enhancement is observed. In multisource scenarios, the importance of shadows appears mitigated, although FM at the periphery of the seed distribution caused underdosage (LDR brachytherapy seed implant dose distributions. Therefore, reduced tumor control could be expected from FM implanted in tumors, although our results are too limited to draw conclusions regarding clinical significance.

  19. A Fully Actuated Robotic Assistant for MRI-Guided Prostate Biopsy and Brachytherapy

    Science.gov (United States)

    Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.

    2014-01-01

    Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm. PMID:25076821

  20. Computed tomographic-guided iodine-125 interstitial implants for malignant thoracic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Qiming [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); The Department of Radiology, Second Affiliated Hospital of Fujian Medical University, 34 Zhongshan Bei Road, Quanzhou 362000 (China); Chen, Jin; Chen, Qunlin [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Lai, Qingquan; Cai, Siqing [The Department of Radiology, Second Affiliated Hospital of Fujian Medical University, 34 Zhongshan Bei Road, Quanzhou 362000 (China); Luo, Kaidong [The Department of Radiology, Longyan Hosptial of Traditional Chinese Medical, 59 Longteng Middle Road, Longyan 364000 (China); Lin, Zhengyu, E-mail: linsinlan@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China)

    2013-11-01

    Purpose: To evaluate the feasibility and efficacy of percutaneous interstitial brachytherapy using iodine-125 ({sup 125}I) radioactive seeds under computed tomographic (CT) guidance for malignant thoracic tumors. Materials and methods: Forty-one patients (34 males, 7 females; 18–90 years; mean, 63.7 years) with 77 lesions (3 in the mediastinum, 7 in the chest wall, 67 in the lung) underwent percutaneous interstitial implantation of {sup 125}I radioactive seeds under CT guidance. A treatment planning system (TPS) was employed to calculate the number and distribution of seeds preoperatively. An 18-G needle was inserted into the lesions under CT guidance and send the seeds according to TPS. Two patients with mediastinal lesions undergoing seed implantation received an artificial pneumothorax. One patient with lung carcinoma adjacent to the anterior mediastinum underwent seed implantation through the sternum. Follow-up CT was done every 2 months postoperatively. Results: The procedure was successful in all patients. No major procedure-associated death occurred. The mean duration of follow-up was 19.4 ± 1.3 months (3–49 months). A complete response (CR) was seen in 49 lesions (63.6%), partial response (PR) in 9 lesions (11.7%), stable disease (SD) in 12 lesions (12.8%), and progressive disease (PD) in 7 lesions (7.4%). The overall response rate (CR + PR) was 75.3%; the local control rate (CR + PR + SD) was 90.9%. The 1-, 2- and 3-year progression-free rates for local tumors were 91%, 88% and 88%, respectively. The 1-, 2- and 3-year survival rates were 87%, 74% and 68%, respectively. Conclusion: Implantation of CT-guided {sup 125}I seeds is feasible and effective for patients with malignant thoracic tumors.

  1. Long-term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    DEFF Research Database (Denmark)

    Iversen, P; Rasmussen, F; Holm, H H

    1991-01-01

    Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months....... Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40......%), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is less than 0.5 ng/ml in 8 of these...

  2. Long-term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    DEFF Research Database (Denmark)

    Iversen, P; Rasmussen, F; Holm, H H

    1991-01-01

    %), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is less than 0.5 ng/ml in 8 of these......Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months....... Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40...

  3. Outcomes and toxicities in patients with intermediate-risk prostate cancer treated with brachytherapy alone or brachytherapy and supplemental external beam radiation therapy.

    Science.gov (United States)

    Schlussel Markovic, Emily; Buckstein, Michael; Stone, Nelson N; Stock, Richard G

    2018-05-01

    To evaluate the cancer control outcomes and long-term treatment-related morbidity of brachytherapy as well as combination brachytherapy and external beam radiation therapy (EBRT) in patients with intermediate-risk prostate cancer. A retrospective review was conducted in a prospectively collected database of patients with intermediate-risk prostate cancer who were treated either with brachytherapy or brachytherapy and EBRT, with or without androgen deprivation therapy (ADT), in the period 1990-2014. Urinary and erectile dysfunction symptoms were measured using the International Prostate Symptom Score (IPSS), the Mount Sinai erectile function scale and the Sexual Health Inventory for Men (SHIM). Cancer control endpoints included biochemical failure and development of distant metastases. All statistical analyses were carried out using the Statistical Package for Social Science (SPSS). Survival curves were calculated using Kaplan-Meier actuarial methods and compared using log-rank tests. Cox regression multivariate analyses were used to test the effect of multiple variables on treatment outcomes. A total of 902 patients were identified, with a median follow-up of 91 months. Of these, 390 received brachytherapy and 512 received combination therapy with EBRT. In patients with one intermediate-risk factor, the addition of EBRT did not significantly affect freedom from biochemical failure or distant metastases. Among patients with two or three intermediate-risk factors, added EBRT did not improve freedom from biochemical failure. Significant differences in late toxicity between patients treated with brachytherapy vs combination brachytherapy and EBRT were identified including urge incontinence (P actuarial methods showed that patients receiving combination therapy more frequently experienced loss of potency, as measured by the Mount Sinai erectile function scale (P = 0.040). Brachytherapy monotherapy results in equal biochemical and distant control in both patients with

  4. Novel high resolution 125I brachytherapy source dosimetry using Ge-doped optical fibres

    International Nuclear Information System (INIS)

    Issa, Fatma; Hugtenburg, Richard P.; Nisbet, Andrew; Bradley, David A.

    2013-01-01

    The steep dose gradients close to brachytherapy sources limit the ability to obtain accurate measurements of dose. Here we use a novel high spatial resolution dosimeter to measure dose around a 125 I source and compare against simulations. Ge-doped optical fibres, used as thermoluminescent dosimeters, offer sub-mm spatial resolution, linear response from 10 cGy to >1 kGy and dose-rate independence. For a 125 I brachytherapy seed in a PMMA phantom, doses were obtained for source-dosimeter separations from 0.1 cm up to several cm, supported by EGSnrc/DOSRZznrc Monte Carlo simulations and treatment planning system data. The measurements agree with simulations to within 2.3%±0.3% along the transverse and perpendicular axes and within 3.0%±0.5% for measurements investigating anisotropy in angular dose distribution. Measured and Veriseed™ brachytherapy treatment planning system (TPS) values agreed to within 2.7%±0.5%. Ge-doped optical fibre dosimeters allow detailed dose mapping around brachytherapy sources, not least in situations of high dose gradient. - Highlights: • We evaluate fall-off in dose for distances from an 125 I source of 1 mm to 60 mm. • The TL of optical fibres accommodate high dose gradients and doses that reduce by a factor of 10 3 across the range of separations. • We verify measured values using DOSRZnrc Monte Carlo code simulations and the Variseed™ Treatment Planning System. • Measured radial and angular dose are obtained with ≤3% uncertainty

  5. Local control after brachytherapy for localized prostatic carcinomas

    International Nuclear Information System (INIS)

    Wachter, T.; Peneau, M.; Sabattier, R.; Breteau, N.

    1996-01-01

    From 1991 to 1995; 31 patients (mid-age: 70 years) underwent prostatic brachytherapy for localized prostate cancers using Iridium 192 transperineal percutaneous interstitial implantation guided by transrectal ultrasonography. Initial staging included among other evaluations a bilateral staging, iliac and obturator lymph nodes dissection. Classification according to stage was : T1b=16%, T1c=36%, T2a=19%, T2b=13%, T2c=13%, T3a=3%. All patients were N (-). Gleason score was 5 for 55%. 77% of the initial PSA was < 25μg/l. Follow-up included one clinical control and psa determination at 1-3-6-12 and 18 months, bone scanning at 12 months and prostate biopsy guided by transrectal ultrasonography at 18, 24, 30 months. Up to now, mean follow-up is 32 months. At one month, psa was normal (< 2,5μg/l) in 21% of the patients, at 12 months 60% and 67% two years after brachytherapy. Biopsies at 18 months were negative for 60% of the patients and 63% at 24 months. 3 patients were metastased after 3 years. 4 patients had severe complications with colostomy and/or urinary derivation. This technic seems to be interesting for localized prostate cancers T1 and T2 with initial psa < 25μg/l. Two third of the patients had normal psa and negative biopsies after 2 years. The rate of ano-rectal and urinary morbidity is high but is explained by the technic used at the beginning of this study

  6. Enzymatic labelling of. gamma. -globulin and insulin with iodine-125

    Energy Technology Data Exchange (ETDEWEB)

    Lucka, B; Russin, K [Institute of Nuclear Physics, Krakow (Poland)

    1979-01-01

    The parameters of enzymatic labelling of proteins with iodine 125 were examined. The manner and sequence of reagent addition, the effects of reagent concentration, reaction time and total Na/sup 125/I activity on the labelling yield were determined.

  7. Impact of short course hormonal therapy on overall and cancer specific survival after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Beyer, David C.; McKeough, Timothy; Thomas, Theresa

    2005-01-01

    Purpose: To review the impact of prior hormonal therapy on 10-year overall and prostate cancer specific survival after primary brachytherapy. Methods and Materials: A retrospective review was performed on the Arizona Oncology Services tumor registry for 2,378 consecutive permanent prostate brachytherapy cases from 1988 through 2001. Hormonal therapy was administered before the implant in 464 patients for downsizing of the prostate or at the discretion of the referring physician. All deceased patients with known clinical recurrence were considered to have died of prostate cancer, irrespective of the immediate cause of death. Risk groups were defined, with 1,135 favorable (prostate-specific antigen [PSA] 70 years (p = 0.0013), Gleason score ≥ 7 (p = 0.0005), and prior hormone use (p = 0.0065) on overall survival. Conclusions: At 10 years, in prostate cancer patients receiving brachytherapy, overall survival is worse in men receiving neoadjuvant hormonal therapy, compared with hormone naive patients. This does not appear to be due to other known risk factors for survival (i.e., stage, grade, PSA, age) on multivariate analysis. The leading causes of death were cardiovascular, prostate cancer, and other cancers with no obvious discrepancy between the two groups. This finding is unexpected and requires confirmation from other centers

  8. Treatment of the prostate cancer with high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Torres Silva, Felipe

    2002-01-01

    The prostate cancer treatment in early stages is controversial. The high dose rate brachytherapy has been used like monotherapy or boost with external beam radiotherapy in advanced disease. This paper describes the technique and the advantages over other modalities

  9. Standards, options and recommendations for brachytherapy of prostate cancer: efficacy and toxicity

    International Nuclear Information System (INIS)

    Pommier, P.; Villers, A.; Bataillard, A.

    2001-01-01

    Context. - The 'Standards, Options and Recommendations' (SOR) collaborative project was initiated in 1993 by the Federation of the French Cancer Centres (FNCLCC), with the 20 French Regional Cancer Centres, several French public university and general hospitals, as well as private clinics and medical specialty societies. Its main objective is the development of serviceable clinical practice guidelines in order to improve the quality of health care and the outcome of cancer patients. The methodology is based on a literature review, followed by a critical appraisal by a multidisciplinary group of experts. Draft guidelines are produced, then validated by specialists in cancer care delivery. Objectives. - Produce technical practice guidelines for the brachytherapy of prostate cancer using the methodology developed by the Standards, Options and Recommendations project. Methods. - The FNCLCC and the French Urology Association (AFU) first designated the multidisciplinary group of experts. Available data were collected by a search of Medline and lists selected by experts in the group. A first draft of the guidelines was written, they validated by independent reviewers. Results. - The main recommendations are: 1/ Brachytherapy with permanent seeds alone is a possible curative treatment for prostate cancer patients with the following prognosis factors: tumour stage T1 or T2a (TNM 1992), Gleason score ≤ 6 and PSA 7 and/or PSA > 10. 3/ Combination of brachytherapy and external beam radiation therapy can be proposed to prostate cancer patients with intermediate prognosis. 4/ Before and after seed implantation, risks of infection must be prevented by appropriate antibiotic therapy (recommendation). 5/ Brachytherapy must not be performed within 2 months of trans-urethral prostate resection. 6/The height of the urethra receiving more than 200 of the prescribed dose must be reported. The portion of the rectum receiving 100 and 120 % of the prescribed dose must be limited to 10

  10. Post-treatment biopsy results following permanent transrectal ultrasound-guided interstitial brachytherapy in early stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Blasko, John C.; Grimm, Peter D.; Hoak, David C.; Cavanagh, Bill; Ragde, Haakon

    1995-01-01

    PURPOSE/OBJECTIVE: Although some controversy remains, most authors agree that post-treatment prostatic biopsy is the best measure of local control in prostate cancer. Brachytherapy series reporting post-implant biopsy results have been few in number, limited in size, and involving older open or combined external beam techniques. The present study was undertaken to assess local control rates as determined by post-implant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound directed, transperineal, computer generated, volume technique. METHOD/MATERIALS: From January 1988 to January 1994, 402 patients received permanent I-125 (285, 71%) or Pd-103 (117, 29%) interstitial brachytherapy as primary treatment for prostatic carcinoma at the Northwest Tumor Institute. Of these, 201 have consented to prostatic biopsy at least 12 months post-implant with a median follow-up of 40 months (range of 12 to 83 months). None had received hormone manipulation. A total of 361 biopsies were performed on 201 patients with a range of 1 to 6 yearly biopsies per patient; 91 receiving multiple biopsies. The other 201 patients were either unable (for geographic reasons) or unwilling to submit for biopsy. However, all patients with a rising PSA or clinical suspicion of recurrence underwent biopsy when possible. The 201 biopsy patients presented with a median age of 69 (range 47 to 89). Stages included 51 T1 (25%), 125 T2a (62%), 22 T2b (11%), and 3 T2c (1%). Gleason sums included 69 2-4 (34%), 117 5-6 (58%), 15 7-10 (7%), and 2 ungraded (1%). The initial PSA was 6.6 (range 0.7 to 74.6). There was no significant difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. 143 received I-125 (71%) prescribed to a minimum peripheral dose of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received Pd-103 prescribed to a

  11. Comparison of CT- and radiograph-based post-implant dosimetry for transperineal 125I prostate brachytherapy using single seeds and a commercial treatment-planning software

    International Nuclear Information System (INIS)

    Siebert, F.A.; Kohr, P.; Kovacs, G.

    2006-01-01

    Background and purpose: the objective of this investigation was a direct comparison of the dosimetry of CT-based and radiograph-based postplanning procedures for seed implants. Patients and methods: CT- and radiograph-based postplans were carried out for eight iodine-125 ( 125 I) seed implant patients with a commercial treatment-planning system (TPS). To assess a direct comparison of the dosimetric indices (D90, V100, V400), the radiograph-based seed coordinates were transformed to the coordinate system of the CT postplan. Afterwards, the CT-based seed positions were replaced by the radiograph-based coordinates in the TPS and the dose distribution was recalculated. Results: the computations demonstrated that the radiograph-based dosimetric values for the prostate (D p 90, V p 100, and V p 400) were on average lower than the values of the CT postplan. Normalized to the CT postplan the following mean values were found: D p 90: 90.6% (standard deviation [SD]: 9.0%), V p 100: 86.1% (SD: 14.7%), and V p 400: 79.4% (SD: 14.4%). For three out of the eight patients the D p 90 decreased to 90% of the initial CT postplan values. The reason for this dosimetric difference is supposed to be evoked by an error of the reconstruction software used. It was detected that the TPS algorithm assigned some sources to wrong coordinates, partly out of the prostate gland. Conclusion: the radiograph-based postplanning technique of the investigated TPS should only be used in combination with CT postplanning. Furthermore, complex testing procedures of reconstruction algorithms are recommended to minimize calculation errors. (orig.)

  12. Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET.

    Science.gov (United States)

    Mason, J; Al-Qaisieh, B; Bownes, P; Henry, A; Thwaites, D

    2013-03-01

    In permanent seed implant prostate brachytherapy the actual dose delivered to the patient may be less than that calculated by TG-43U1 due to interseed attenuation (ISA) and differences between prostate tissue composition and water. In this study the magnitude of the ISA effect is assessed in a phantom and in clinical prostate postimplant cases. Results are compared for seed models 6711 and 9011 with 0.8 and 0.5 mm diameters, respectively. A polymethyl methacrylate (PMMA) phantom was designed to perform ISA measurements in a simple eight-seed arrangement and at the center of an implant of 36 seeds. Monte Carlo (MC) simulation and experimental measurements using a MOSFET dosimeter were used to measure dose rate and the ISA effect. MC simulations of 15 CT-based postimplant prostate treatment plans were performed to compare the clinical impact of ISA on dose to prostate, urethra, rectum, and the volume enclosed by the 100% isodose, for 6711 and 9011 seed models. In the phantom, ISA reduced the dose rate at the MOSFET position by 8.6%-18.3% (6711) and 7.8%-16.7% (9011) depending on the measurement configuration. MOSFET measured dose rates agreed with MC simulation predictions within the MOSFET measurement uncertainty, which ranged from 5.5% to 7.2% depending on the measurement configuration (k = 1, for the mean of four measurements). For 15 clinical implants, the mean ISA effect for 6711 was to reduce prostate D90 by 4.2 Gy (3%), prostate V100 by 0.5 cc (1.4%), urethra D10 by 11.3 Gy (4.4%), rectal D2cc by 5.5 Gy (4.6%), and the 100% isodose volume by 2.3 cc. For the 9011 seed the mean ISA effect reduced prostate D90 by 2.2 Gy (1.6%), prostate V100 by 0.3 cc (0.7%), urethra D10 by 8.0 Gy (3.2%), rectal D2cc by 3.1 Gy (2.7%), and the 100% isodose volume by 1.2 cc. Differences between the MC simulation and TG-43U1 consensus data for the 6711 seed model had a similar impact, reducing mean prostate D90 by 6 Gy (4.2%) and V100 by 0.6 cc (1.8%). ISA causes the delivered dose

  13. Directional interstitial brachytherapy from simulation to application

    Science.gov (United States)

    Lin, Liyong

    Organs at risk (OAR) are sometimes adjacent to or embedded in or overlap with the clinical target volume (CTV) to be treated. The purpose of this PhD study is to develop directionally low energy gamma-emitting interstitial brachytherapy sources. These sources can be applied between OAR to selectively reduce hot spots in the OARs and normal tissues. The reduction of dose over undesired regions can expand patient eligibility or reduce toxicities for the treatment by conventional interstitial brachytherapy. This study covers the development of a directional source from design optimization to construction of the first prototype source. The Monte Carlo code MCNP was used to simulate the radiation transport for the designs of directional sources. We have made a special construction kit to assemble radioactive and gold-shield components precisely into D-shaped titanium containers of the first directional source. Directional sources have a similar dose distribution as conventional sources on the treated side but greatly reduced dose on the shielded side, with a sharp dose gradient between them. A three-dimensional dose deposition kernel for the 125I directional source has been calculated. Treatment plans can use both directional and conventional 125I sources at the same source strength for low-dose-rate (LDR) implants to optimize the dose distributions. For prostate tumors, directional 125I LDR brachytherapy can potentially reduce genitourinary and gastrointestinal toxicities and improve potency preservation for low risk patients. The combination of better dose distribution of directional implants and better therapeutic ratio between tumor response and late reactions enables a novel temporary LDR treatment, as opposed to permanent or high-dose-rate (HDR) brachytherapy for the intermediate risk T2b and high risk T2c tumors. Supplemental external-beam treatments can be shortened with a better brachytherapy boost for T3 tumors. In conclusion, we have successfully finished the

  14. Influence of 125I seed interstitial brachytherapy on recovery of facial nerve function

    International Nuclear Information System (INIS)

    Song Tieli; Zheng Lei; Zhang Jie; Cai Zhigang; Yang Zhaohui; Yu Guangyan; Zhang Jianguo

    2010-01-01

    Objective: To study the influence of 125 I seed interstitial brachytherapy in parotid region on the recovery of facial nerve function. Methods: A total of the data of 21 patients with primary parotid carcinoma were treated with resection and 125 I interstitial brachytherapy. All the patients had no facial palsy before operation and the prescribed dose was 60 Gy. During 4 years of follow-up, the House-Brackmann grading scales and ENoG were used to evaluate the function of facial nerve. According to the modified regional House-Brackmann grading scales, the facial nerve branches of patients in affected side were divided into normal and abnormal groups, and were compared with those in contra-lateral side. Results: Post-operation facial palsy occurred in all the patients, but the facial palsy recovered within 6 months. The latency time differences between affected side and contralateral side were statistically significant in abnormal group from 1 week to 6 months after treatment (t=2.362, P=0.028), and were also different in normal group 1 week after treatment (t=2.522, P=0.027). Conclusions: 125 I interstitital brachytherapy has no influence on recovery of facial nerve function after tumor resection and no delayed facial nerve damage. (authors)

  15. Long term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Iversen, P; Rasmussen, F; Holm, H H [Depts. of Urology and Ultrasound, Herlev Hospital, Univ. of Copenhagen (Denmark)

    1991-01-01

    Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months. Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40%), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is bigger than 0.5 ng/ml in 8 of these. The future role of ultrasonically guided implantation in the management of prostatic cancer is discussed. (au).

  16. Low-dose-rate brachytherapy for patients with transurethral resection before implantation in prostate cancer: long-term results

    International Nuclear Information System (INIS)

    Prada, Pedro J.; Anchuelo, Javier; Blanco, Ana Garcia; Paya, Gema; Cardenal, Juan; Acuña, Enrique; Ferri, Maria; Vazquez, Andres; Pacheco, Maite; Sanchez, Jesica

    2016-01-01

    Objectives: We analyzed the long-term oncologic outcome for patients with prostate cancer and transurethral resection who were treated using low-dose-rate (LDR) prostate brachytherapy. Methods and Materials: From January 2001 to December 2005, 57 consecutive patients were treated with clinically localized prostate cancer. No patients received external beam radiation. All of them underwent LDR prostate brachytherapy. Biochemical failure was defined according to the 'Phoenix consensus'. Patients were stratified as low and intermediate risk based on The Memorial Sloan Kettering group definition. Results: The median follow-up time for these 57 patients was 104 months. The overall survival according to Kaplan-Meier estimates was 88% (±6%) at 5 years and 77% (±6%) at 12 years. The 5 and 10 years for failure in tumour-free survival (TFS) was 96% and respectively (±2%), whereas for biochemical control was 94% and respectively (±3%) at 5 and 10 years, 98% (±1%) of patients being free of local recurrence. A patient reported incontinence after treatment (1.7%). The chronic genitourinary complains grade I were 7% and grade II, 10%. At six months 94% of patients reported no change in bowel function. Conclusions: The excellent long-term results and low morbidity presented, as well as the many advantages of prostate brachytherapy over other treatments, demonstrates that brachytherapy is an effective treatment for patients with transurethral resection and clinical organ-confined prostate cancer. (author)

  17. Low-dose-rate brachytherapy for patients with transurethral resection before implantation in prostate cancer: long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Prada, Pedro J.; Anchuelo, Javier; Blanco, Ana Garcia; Paya, Gema; Cardenal, Juan; Acuña, Enrique; Ferri, Maria [Department of Radiation Oncology, Hospital Universitario Marqués de Valdecilla, Santander, Cantabria (Spain); Vazquez, Andres; Pacheco, Maite; Sanchez, Jesica [Department of Radiation Physics, Hospital Universitario Marqués de Valdecilla, Santander, Cantabria (Spain)

    2016-01-15

    Objectives: We analyzed the long-term oncologic outcome for patients with prostate cancer and transurethral resection who were treated using low-dose-rate (LDR) prostate brachytherapy. Methods and Materials: From January 2001 to December 2005, 57 consecutive patients were treated with clinically localized prostate cancer. No patients received external beam radiation. All of them underwent LDR prostate brachytherapy. Biochemical failure was defined according to the 'Phoenix consensus'. Patients were stratified as low and intermediate risk based on The Memorial Sloan Kettering group definition. Results: The median follow-up time for these 57 patients was 104 months. The overall survival according to Kaplan-Meier estimates was 88% (±6%) at 5 years and 77% (±6%) at 12 years. The 5 and 10 years for failure in tumour-free survival (TFS) was 96% and respectively (±2%), whereas for biochemical control was 94% and respectively (±3%) at 5 and 10 years, 98% (±1%) of patients being free of local recurrence. A patient reported incontinence after treatment (1.7%). The chronic genitourinary complains grade I were 7% and grade II, 10%. At six months 94% of patients reported no change in bowel function. Conclusions: The excellent long-term results and low morbidity presented, as well as the many advantages of prostate brachytherapy over other treatments, demonstrates that brachytherapy is an effective treatment for patients with transurethral resection and clinical organ-confined prostate cancer. (author)

  18. Early quality of life outcomes in patients with prostate cancer managed by high-dose-rate brachytherapy as monotherapy

    International Nuclear Information System (INIS)

    Komiya, Akira; Fujiuchi, Yasuyoshi; Ito, Takatoshi

    2013-01-01

    The purpose of this study was to evaluate the early quality of life outcomes in prostate cancer patients managed by high-dose-rate brachytherapy as monotherapy. A total of 51 patients with cT1c-T3aN0M0 prostate cancer treated between July 2007 and January 2010 were included in this study. The average age was 69?years, and the average initial serum prostate-specific antigen was 10.98?ng/mL. A total of 25, 18 and eight patients were considered to be low, intermediate and high risk, respectively. All patients received one implant of Ir-192 and seven fractions of 6.5?Gy within 3.5?days for a total prescribed dose of 45.5?Gy. For high-risk prostate cancer, neoadjuvant androgen deprivation therapy was carried out for at least 6?months, and continued after high-dose-rate brachytherapy. Quality of life outcomes were measured by using the International Prostate Symptom Score, the Functional Assessment of Cancer Therapy-Prostate and the International Index of Erectile Function Questionnaire. The oncological outcome was assessed by serum prostate-specific antigen and diagnostic imaging. Adverse events were also recorded. The Functional Assessment of Cancer Therapy-Prostate scores decreased for a few months after high-dose-rate brachytherapy, and recovered to pretreatment condition thereafter. The International Prostate Symptom Score significantly increased 2?weeks after treatment for each of its items and their sum, and it returned to baseline after 12?weeks. Sexual function decreased at 2 and 4?weeks, and recovered after 12?weeks. Severe complications were rare. Within a median follow up of 17.2?months, two patients showed a prostate-specific antigen recurrence. High-dose-rate brachytherapy for prostate cancer is a feasible treatment modality with acceptable toxicity and only a limited impact on the quality of life. (author)

  19. HDR Brachytherapy in the Management of High-Risk Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Susan Masson

    2012-01-01

    Full Text Available High-dose-rate (HDR brachytherapy is used with increasing frequency for the treatment of prostate cancer. It is a technique which allows delivery of large individual fractions to the prostate without exposing adjacent normal tissues to unacceptable toxicity. This approach is particularly favourable in prostate cancer where tumours are highly sensitive to dose escalation and to increases in radiotherapy fraction size, due to the unique radiobiological behaviour of prostate cancers in contrast with other malignancies. In this paper we discuss the rationale and the increasing body of clinical evidence for the use of this technique in patients with high-risk prostate cancer, where it is combined with external beam radiotherapy. We highlight practical aspects of delivering treatment and discuss toxicity and limitations, with particular reference to current practice in the United Kingdom.

  20. Shifting brachytherapy monotherapy case mix toward intermediate-risk prostate cancer.

    Science.gov (United States)

    Muralidhar, Vinayak; Mahal, Brandon A; Ziehr, David R; Chen, Yu-Wei; Nezolosky, Michelle D; Viswanathan, Vidya B; Beard, Clair J; Devlin, Phillip M; Martin, Neil E; Orio, Peter F; Nguyen, Paul L

    2015-01-01

    The relative use of brachytherapy (BT) for prostate cancer has declined in recent years. In this setting, we sought to determine whether the case mix of BT monotherapy-treated men has changed over time in terms of risk group composition. The Surveillance, Epidemiology, and End Results database was used to identify 30,939 patients diagnosed with prostate adenocarcinoma between 2004 and 2011 who received BT monotherapy. The case mix of BT monotherapy patients was calculated by patient risk group and year of diagnosis. Between 2004 and 2011, the use of BT monotherapy declined overall. The relative percentage of men undergoing BT with low-risk disease declined by 4.5%, whereas the relative percentage of patients with intermediate-risk disease increased by 4.7%. Non-white patients and those from poorer counties did not show shifts in the risk group makeup of BT monotherapy patients, whereas white patients and those from wealthier counties did. Although fewer patients with prostate cancer are undergoing BT monotherapy, men with intermediate-risk disease comprised a significantly larger portion of the BT case mix in 2011 compared with 2004. Future research efforts by brachytherapists should be directed toward improving BT technique, optimizing radiation doses, and obtaining long-term followup data for patients with intermediate-risk prostate cancer. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  1. Treatment of prostate adenocarcinoma permanent implants with I 125: first experience in Uruguay; Tratamiento del adenocarcinoma de prostata con implantes permanentes de I125: primera experiencia en el Uruguay

    Energy Technology Data Exchange (ETDEWEB)

    Quarneti, A.; Clark, O.; Glaussius, A.; Kaitasoff, P.; Cosia, G.

    2010-12-15

    Full text: Objective: To report on the treatment done, toxicity and development of a group of adenocarcinoma patients with localized prostate brachytherapy implants permanent I125. Material and Methods. 37 patients were treated in the period 2001 to 2004 at the Military Hospital Central by this treatment modality. All of them were performed before implantation planning, which consisted of the volumetric calculation and calculation prostate dosimetry that included transrectal prostate ultrasound 3-5 weeks before the procedure. all patients had pathological confirmation of the lesion showed PSA values less than 11 ng / ml and Gleason score less than 7. 70% of patients received neo-adjuvant hormone therapy. In 5 patients an interactive planning system was performed computerized dosimetry, using sequential ultrasound imaging planes, allowed the dosimetric analysis before terminate the procedure and make necessary adjustments if the dose distribution did not conform. This additional dosimetric study we have not been described by other authors. Prescribed in the first 10 patients was dose 144 Gy and 160 Gy in subsequent. All patients underwent post implant CT waffle grid after 15 days of the procedure. analyzed the dose volume histogram (HDV) and D90 values??. Clinical follow-up was performed and PSA biochemical .. Preliminary Results: 33 patients were in local control without biochemical failure. Currently 4 patients presented biochemical recurrence with PSA values ??between 4 and 6 ng / ml. In neither disease was found at a distance and then raises confirmation tumor biopsy active presence will undergo surgical treatment protocols localized prostate cancer. HDV values ??D90 and are consistent with the informed by the international literature will be presented. No patient required hospitalization prolonged (greater than 24 hours) or use of higher analgesics. 2 patients had acute urinary retention (G II complication) between the tenth and twentieth day, the rest of the

  2. Comparison between external beam radiotherapy (70 Gy/74 Gy) and permanent interstitial brachytherapy in 890 intermediate risk prostate cancer patients

    International Nuclear Information System (INIS)

    Goldner, Gregor; Pötter, Richard; Battermann, Jan J.; Kirisits, Christian; Schmid, Maximilian P.; Sljivic, Samir; Vulpen, Marco van

    2012-01-01

    Purpose: Aim of this analysis was to compare biochemical no evidence of disease (bNED) rates in intermediate-risk prostate-cancer patients treated at two centres of excellence using different approaches: permanent interstitial brachytherapy (BT) and external beam radiotherapy (EBRT). Materials and methods: A total of 890 intermediate-risk prostate-cancer patients, who were treated from 1998 to 2008, were identified in the two local databases. In Utrecht 601 patients received I-125 BT applying a dose of 144 Gy. In Vienna 289 patients were treated by EBRT, applying a local dose of 70 Gy in 105 patients and 74 Gy in 184 patients. bNED-rates (Phoenix-definition) were assessed. Results: Median follow-up was 48 months (1–150). 5-Year actuarial bNED-rates were 81% for BT-patients and 75% for EBRT-patients (67% for 70 Gy and 82% for 74 Gy), respectively. In univariate analysis no difference between BT and EBRT could be detected. In multivariate analysis including tumour-stage, GleasonScore, initial PSA, hormonal therapy and treatment-centre (BT vs. EBRT) only T-stage, GleasonScore and PSA were found to be significant. Additional analysis including radiation dose showed the same outcome. Conclusions: Intermediate-risk prostate cancer patients treated by permanent interstitial brachytherapy show biochemical tumour-control-rates which are comparable to EBRT of 74 Gy.

  3. Side effects of permanent I125 prostate seed implants in 667 patients treated in Leeds

    International Nuclear Information System (INIS)

    Bottomley, David; Ash, Dan; Al-Qaisieh, Bashar; Carey, Brendan; Joseph, Joji; St Clair, Shaun; Gould, Kathy

    2007-01-01

    Purpose: To report the side effects and complications after I-125 seeds prostate implant after 8.5 years experience. Methods and materials: Six hundred and sixty seven (667) patients were treated between March 1995 and December 2001. The median follow up is 31 months with a maximum of 98.2 months. Morbidity data were collected from a review of patient case-notes. Patients also provided prospective data on urinary symptoms using the International Prostate Symptom Score (IPSS) scoring chart before treatment and at regular follow up. Patients were also sent a questionnaire detailing symptoms and side effects following their brachytherapy. This enabled them to record urinary, bowel and sexual function side effects independently. Logistic regression analysis was carried out to identify the risk of catheterisation in relation to the pre-implant prostate volume and potential implant factors such as the number of seeds and needles and implant dose. Result: The urinary symptom score rises in the first few months after implantation and returns to within one or two points of the pre-treatment score within one year. Nine patients reported incontinence prior to treatment and 15, 12 and 10 patients reported incontinence 6, 12 and 24 months after treatment, respectively. Catheterisation was reported in 97 (14.5%) patients. At six months 84.9% of patients reported no change in bowel function and 78.9% at 12 months. 6.4% of patients complained of some increased bowel frequency at 6 months and 5.7% at 12 months. 402 (77.2%) patients reported being fully potent before treatment and that this fell to 32.4% after treatment. Logistic regression showed that the most significant factors which correlate with the probability of catheterisation are the pre-treatment prostate volume and the number of seeds and needles implanted. Conclusion: The side effects and complications after prostate brachytherapy as reported here and elsewhere confirm that the treatment is not only convenient but also

  4. Dosimetric studies, spectrometric, radiographic, metallographic of a new argentinean seed of 125 I used in brachytherapy

    International Nuclear Information System (INIS)

    Pirchio, R.; Saravi, M.; Banchik, D.; Munoz, C.

    2006-01-01

    A new source of 125 I model Braquibac TM has been developed in Argentina for applications in interstitial brachytherapy. The AAPM Task Group 43 (TG-43) recommends that dosimetric characteristics of new sources of brachytherapy of Iodine-125 have been theoretically and experimentally determined before its clinical use. The objectives outlined in this work were the study of the design of the new seed, the calculation of dosimetric parameters and the photons spectra analysis. Its were carried out radiographic and metallographic studies to determine the physical characteristics of the source. For the realization of the dosimetric calculations it was used the Monte Carlo code MCNP5. Values of the radial dose function, g(r), of the constant of dose rate, Λ, of the function of anisotropy of two dimensions, F(r, θ), of the factor and constant of anisotropy its were obtained simulating the source in water according to the recommended methodology in TG-43. The constant of dose rate is similar to 0,880 ± 0,080 c Gy h -1 U -1 . The kerma in air rate of reference, S K , was calculated as 1,036 c Gy cm 2 h -1 mCi -1 simulating the seed in dry air. Its were carried out spectrometric studies using a semiconductor planar detector of HPGe (high purity germanium). Photons spectra showed characteristic x-rays of 125 I with energies of 27,20 keV, 27,47 keV, 31 keV and 31,70 keV gamma photons of 35,5 keV, and x-ray fluorescent coming from the silver nucleus of 22,10 keV, 24,94 keV and 25,45 keV. The angular dependence of the intensity of photons around the seed and in air it was analyzed with the planar detector. This was carried out to study the anisotropy in the photons flow due to variation in the thickness of the titanium wall and of the welding, movements of the silver tube inside the source and deposition of the radioactive material on the silver tube. (Author)

  5. The use of nomograms in LDR-HDR prostate brachytherapy.

    Science.gov (United States)

    Pujades, Ma Carmen; Camacho, Cristina; Perez-Calatayud, Jose; Richart, José; Gimeno, Jose; Lliso, Françoise; Carmona, Vicente; Ballester, Facundo; Crispín, Vicente; Rodríguez, Silvia; Tormo, Alejandro

    2011-09-01

    The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques. Patients treated throughout 2010 till April 2011 were considered for this study. This example was chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficient number of cases for both BT modalities, prescription dose and different work methodology (depending on the institution) were taken into account. The specific nomograms were built using the correlation between the prostate volume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, number of implanted seeds in LDR or total radiation time in HDR. For each institution and BT modality, nomograms normalized to the prescribed dose were obtained and fitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting. It should be noted that for each institution these linear function parameters are different, indicating that each centre should construct its own nomograms. Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific for each institution. Nevertheless, their use should be complementary to the necessary independent verification.

  6. T2*-weighted image/T2-weighted image fusion in postimplant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Katayama, Norihisa; Takemoto, Mitsuhiro; Yoshio, Kotaro

    2011-01-01

    Computed tomography (CT)/magnetic resonance imaging (MRI) fusion is considered to be the best method for postimplant dosimetry of permanent prostate brachytherapy; however, it is inconvenient and costly. In T2 * -weighted image (T2 * -WI), seeds can be easily detected without the use of an intravenous contrast material. We present a novel method for postimplant dosimetry using T2 * -WI/T2-weighted image (T2-WI) fusion. We compared the outcomes of T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based postimplant dosimetry. Between April 2008 and July 2009, 50 consecutive prostate cancer patients underwent brachytherapy. All the patients were treated with 144 Gy of brachytherapy alone. Dose-volume histogram (DVH) parameters (prostate D90, prostate V100, prostate V150, urethral D10, and rectal D2cc) were prospectively compared between T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based dosimetry. All the DVH parameters estimated by T2 * -WI/T2-WI fusion-based dosimetry strongly correlated to those estimated by CT/T2-WI fusion-based dosimetry (0.77≤ R ≤0.91). No significant difference was observed in these parameters between the two methods, except for prostate V150 (p=0.04). These results show that T2 * -WI/T2-WI fusion-based dosimetry is comparable or superior to MRI-based dosimetry as previously reported, because no intravenous contrast material is required. For some patients, rather large differences were observed in the value between the 2 methods. We thought these large differences were a result of seed miscounts in T2 * -WI and shifts in fusion. Improving the image quality of T2 * -WI and the image acquisition speed of T2 * -WI and T2-WI may decrease seed miscounts and fusion shifts. Therefore, in the future, T2 * -WI/T2-WI fusion may be more useful for postimplant dosimetry of prostate brachytherapy. (author)

  7. Autoradiography for iodine-125 seeds

    International Nuclear Information System (INIS)

    Alberti, W.; Divoux, S.; Pothmann, B.; Tabor, P.; Hermann, K.P.; Harder, D.

    1993-01-01

    To study the interior design of model 6702 and 6711 iodine-125 seeds, contact autoradiographs were performed using mammography film. Improved resolution was obtained using a pin-hole camera with a hole of 0.1 mm x 0.1 mm. With these techniques, qualitative determination of the relative activity distribution within each seed was possible. The number of the activated resin spheres and the positions of the centers of these spheres can be exactly determined. A model calculation shows that variations in the arrangement of the activated spheres within a seed have a moderate influence on the dose distribution at source distances below 10 mm. Knowing the exact source configuration may be useful when comparing dose calculations with measured data for model 6702 125 I seeds which are currently employed in ophthalmic plaque and implant therapy of other tumors. 16 refs., 5 figs., 2 tabs

  8. Radiation protection data sheets for the use of iodine 125 in unsealed sources

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This radiation protection data sheet is intended for supervisors and staff in the different medical, hospital, pharmaceutical, university and industrial laboratories and departments where Iodine 125 is handled, and also for all those involved in risk prevention in this field. It provides essential data on radiation protection measures during the use of Iodine 125 in unsealed sources: physical characteristics, risk assessment, administrative procedures, recommendations, regulations and bibliography

  9. Occupational exposure of professionals during interstitial permanent prostate brachytherapy implants

    International Nuclear Information System (INIS)

    Pirraco, R.; Pereira, A.; Viterbo, T.; Cavaco, A.

    2006-01-01

    Full text of publication follows: Introduction: In this study we present dose measurements for professionals exposed during interstitial 125 I permanent prostate brachytherapy implants. Methods and Materials: The implant technique used was intra operative real time using strand and loose seeds. The professionals inside the operating room are an oncologist, a radiologist, a physicist, a nurse and an anesthesiologist. The oncologist and the physicist contact directly the loaded needle with radioactive seeds and two types of measurements were taken: total body and extremities (finger) dose. The rest of the team operates at long distances, but measurements were made. To measure total body equivalent dose we use a Berthold Umo LB 123 coupled with a LB 1236-H10 detector, and we recorded dose, time and distance from implant location. Finger dosemeters are thermo -luminescent dosimeter (TLD) rings that were controlled over one month. Results: 50 cases (average number of applications per year) were analysed for extremities measurements and 9 cases for total body measurements (in this case, the results were extrapolated for 50 cases), with an average of 26.1 mCi total activity per implant (in a range of 17.4 - 40.3 mCi). The finger dose was 1.8 mSv for the oncologist and 1.9 mSv for the physicist. The interpolation of total body equivalent dose for the oncologist was 24 mSv, for the radiologist 6 mSv and 9 mSv for the physicist. The rest of the team did not receive anything but background radiation. The annual national limit dose for workers is 20 mSv for total body irradiation, and 500 mSv for extremities. Conclusion: In conclusion we may say that during interstitial permanent prostate brachytherapy implants, total doses received for all groups are not significant when compared to annual limits for Portuguese laws 1. Even so, our main goal is always to get the less possible dose (ALARA principle). References: 1. Decreto Lei n. 180/2002 de 8 de Agosto. (authors)

  10. Occupational exposure of professionals during interstitial permanent prostate brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Pirraco, R.; Pereira, A.; Viterbo, T.; Cavaco, A. [Instituto Portugues de Oncologia Francisco Gentil, Centro R egional de Oncologia do Porto, SA, Porto (Portugal)

    2006-07-01

    Full text of publication follows: Introduction: In this study we present dose measurements for professionals exposed during interstitial 125 I permanent prostate brachytherapy implants. Methods and Materials: The implant technique used was intra operative real time using strand and loose seeds. The professionals inside the operating room are an oncologist, a radiologist, a physicist, a nurse and an anesthesiologist. The oncologist and the physicist contact directly the loaded needle with radioactive seeds and two types of measurements were taken: total body and extremities (finger) dose. The rest of the team operates at long distances, but measurements were made. To measure total body equivalent dose we use a Berthold Umo LB 123 coupled with a LB 1236-H10 detector, and we recorded dose, time and distance from implant location. Finger dosemeters are thermo -luminescent dosimeter (TLD) rings that were controlled over one month. Results: 50 cases (average number of applications per year) were analysed for extremities measurements and 9 cases for total body measurements (in this case, the results were extrapolated for 50 cases), with an average of 26.1 mCi total activity per implant (in a range of 17.4 - 40.3 mCi). The finger dose was 1.8 mSv for the oncologist and 1.9 mSv for the physicist. The interpolation of total body equivalent dose for the oncologist was 24 mSv, for the radiologist 6 mSv and 9 mSv for the physicist. The rest of the team did not receive anything but background radiation. The annual national limit dose for workers is 20 mSv for total body irradiation, and 500 mSv for extremities. Conclusion: In conclusion we may say that during interstitial permanent prostate brachytherapy implants, total doses received for all groups are not significant when compared to annual limits for Portuguese laws 1. Even so, our main goal is always to get the less possible dose (ALARA principle). References: 1. Decreto Lei n. 180/2002 de 8 de Agosto. (authors)

  11. Comparison of biochemical failure definitions for permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Kuban, Deborah A.; Levy, Larry B.; Potters, Louis; Beyer, David C.; Blasko, John C.; Moran, Brian J.; Ciezki, Jay P.; Zietman, Anthony L.; Zelefsky, Michael J.; Pisansky, Thomas M.; Elshaikh, Mohamed; Horwitz, Eric M.

    2006-01-01

    Purpose: To assess prostate-specific antigen (PSA) failure definitions for patients with Stage T1-T2 prostate cancer treated by permanent prostate brachytherapy. Methods and Materials: A total of 2,693 patients treated with radioisotopic implant as solitary treatment for T1-T2 prostatic adenocarcinoma were studied. All patients had a pretreatment PSA, were treated at least 5 years before analysis, 1988 to 1998, and did not receive hormonal therapy before recurrence. Multiple PSA failure definitions were tested for their ability to predict clinical failure. Results: Definitions which determined failure by a certain increment of PSA rise above the lowest PSA level to date (nadir + x ng/mL) were more sensitive and specific than failure definitions based on PSA doubling time or a certain number of PSA rises. The sensitivity and specificity for the nadir + 2 definition were 72% and 83%, vs. 51% and 81% for 3 PSA rises. The surgical type definitions (PSA exceeding an absolute value) could match this sensitivity and specificity but only when failure was defined as exceeding a PSA level in the 1-3 ng/mL range and only when patients were allowed adequate time to nadir. When failure definitions were compared by time varying covariate regression analysis, nadir + 2 ng/mL retained the best fit. Conclusions: For patients treated by permanent radioisotopic implant for prostate cancer, the definition nadir + 2 ng/mL provides the best surrogate for failure throughout the entire follow-up period, similar to patients treated by external beam radiotherapy. Therefore, the same PSA failure definition could be used for both modalities. For brachytherapy patients with long-term follow-up, at least 6 years, defining failure as exceeding an absolute PSA level in the 0.5 ng/mL range may be reasonable

  12. Conventional Versus Automated Implantation of Loose Seeds in Prostate Brachytherapy: Analysis of Dosimetric and Clinical Results

    International Nuclear Information System (INIS)

    Genebes, Caroline; Filleron, Thomas; Graff, Pierre; Jonca, Frédéric; Huyghe, Eric; Thoulouzan, Matthieu; Soulie, Michel; Malavaud, Bernard; Aziza, Richard; Brun, Thomas; Delannes, Martine; Bachaud, Jean-Marc

    2013-01-01

    Purpose: To review the clinical outcome of I-125 permanent prostate brachytherapy (PPB) for low-risk and intermediate-risk prostate cancer and to compare 2 techniques of loose-seed implantation. Methods and Materials: 574 consecutive patients underwent I-125 PPB for low-risk and intermediate-risk prostate cancer between 2000 and 2008. Two successive techniques were used: conventional implantation from 2000 to 2004 and automated implantation (Nucletron, FIRST system) from 2004 to 2008. Dosimetric and biochemical recurrence-free (bNED) survival results were reported and compared for the 2 techniques. Univariate and multivariate analysis researched independent predictors for bNED survival. Results: 419 (73%) and 155 (27%) patients with low-risk and intermediate-risk disease, respectively, were treated (median follow-up time, 69.3 months). The 60-month bNED survival rates were 95.2% and 85.7%, respectively, for patients with low-risk and intermediate-risk disease (P=.04). In univariate analysis, patients treated with automated implantation had worse bNED survival rates than did those treated with conventional implantation (P<.0001). By day 30, patients treated with automated implantation showed lower values of dose delivered to 90% of prostate volume (D90) and volume of prostate receiving 100% of prescribed dose (V100). In multivariate analysis, implantation technique, Gleason score, and V100 on day 30 were independent predictors of recurrence-free status. Grade 3 urethritis and urinary incontinence were observed in 2.6% and 1.6% of the cohort, respectively, with no significant differences between the 2 techniques. No grade 3 proctitis was observed. Conclusion: Satisfactory 60-month bNED survival rates (93.1%) and acceptable toxicity (grade 3 urethritis <3%) were achieved by loose-seed implantation. Automated implantation was associated with worse dosimetric and bNED survival outcomes

  13. Conventional Versus Automated Implantation of Loose Seeds in Prostate Brachytherapy: Analysis of Dosimetric and Clinical Results

    Energy Technology Data Exchange (ETDEWEB)

    Genebes, Caroline, E-mail: genebes.caroline@claudiusregaud.fr [Radiation Oncology Department, Institut Claudius Regaud, Toulouse (France); Filleron, Thomas; Graff, Pierre [Radiation Oncology Department, Institut Claudius Regaud, Toulouse (France); Jonca, Frédéric [Department of Urology, Clinique Ambroise Paré, Toulouse (France); Huyghe, Eric; Thoulouzan, Matthieu; Soulie, Michel; Malavaud, Bernard [Department of Urology and Andrology, CHU Rangueil, Toulouse (France); Aziza, Richard; Brun, Thomas; Delannes, Martine; Bachaud, Jean-Marc [Radiation Oncology Department, Institut Claudius Regaud, Toulouse (France)

    2013-11-15

    Purpose: To review the clinical outcome of I-125 permanent prostate brachytherapy (PPB) for low-risk and intermediate-risk prostate cancer and to compare 2 techniques of loose-seed implantation. Methods and Materials: 574 consecutive patients underwent I-125 PPB for low-risk and intermediate-risk prostate cancer between 2000 and 2008. Two successive techniques were used: conventional implantation from 2000 to 2004 and automated implantation (Nucletron, FIRST system) from 2004 to 2008. Dosimetric and biochemical recurrence-free (bNED) survival results were reported and compared for the 2 techniques. Univariate and multivariate analysis researched independent predictors for bNED survival. Results: 419 (73%) and 155 (27%) patients with low-risk and intermediate-risk disease, respectively, were treated (median follow-up time, 69.3 months). The 60-month bNED survival rates were 95.2% and 85.7%, respectively, for patients with low-risk and intermediate-risk disease (P=.04). In univariate analysis, patients treated with automated implantation had worse bNED survival rates than did those treated with conventional implantation (P<.0001). By day 30, patients treated with automated implantation showed lower values of dose delivered to 90% of prostate volume (D90) and volume of prostate receiving 100% of prescribed dose (V100). In multivariate analysis, implantation technique, Gleason score, and V100 on day 30 were independent predictors of recurrence-free status. Grade 3 urethritis and urinary incontinence were observed in 2.6% and 1.6% of the cohort, respectively, with no significant differences between the 2 techniques. No grade 3 proctitis was observed. Conclusion: Satisfactory 60-month bNED survival rates (93.1%) and acceptable toxicity (grade 3 urethritis <3%) were achieved by loose-seed implantation. Automated implantation was associated with worse dosimetric and bNED survival outcomes.

  14. PSA Nadir of <0.5 ng/mL Following Brachytherapy for Early-Stage Prostate Adenocarcinoma is Associated With Freedom From Prostate-Specific Antigen Failure

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Eric C. [Department of Radiation Oncology, Mount Sinai Medical Center, New York, NY (United States); Stone, Nelson N. [Department of Radiation Oncology, Mount Sinai Medical Center, New York, NY (United States); Department of Urology, Mount Sinai Medical Center, New York, NY (United States); Stock, Richard G., E-mail: Richard.Stock@mountsinai.org [Department of Radiation Oncology, Mount Sinai Medical Center, New York, NY (United States)

    2012-06-01

    Purpose: Because limited information exists regarding whether the rate or magnitude of PSA decline following brachytherapy predicts long-term clinical outcomes, we evaluated whether achieving a prostate-specific antigen (PSA) nadir (nPSA) <0.5 ng/mL following brachytherapy is associated with decreased PSA failure and/or distant metastasis. Methods and Materials: We retrospectively analyzed our database of early-stage prostate adenocarcinoma patients who underwent brachytherapy, excluding those receiving androgen-deprivation therapy and those with <2 years follow-up. Median and mean pretreatment PSA were 6 ng/mL and 7.16 ng/mL, respectively. By clinical stage, 775 were low risk ({<=}T2a), 126 were intermediate risk (T2b), and 20 were high risk (>T2b). By Gleason score, 840 were low risk ({<=}6), 71 were intermediate risk (7), and 10 were high risk (>7). Patients were treated with brachytherapy only (I-125, n = 779, or Pd-103, n = 47), or brachytherapy + external-beam radiation therapy (n = 95). Median follow-up was 6.3 years. We noted whether nPSA <0.5 ng/mL was achieved and the time to achieve this nadir and tested for associations with pretreatment risk factors. We also determined whether this PSA endpoint was associated with decreased PSA failure or distant metastasis. Results: Absence of high-risk factors in clinical stage ({<=}T2b), Gleason score ({<=}7), and pretreatment PSA ({<=}20 ng/mL) was significantly associated with achieving nPSA <0.5 ng/mL. By Kaplan-Meier analysis, patients achieving nPSA <0.5 ng/mL had significantly higher long-term freedom from biochemical failure (FFBF) than nonresponders (5-year FFBF: 95.2 {+-} 0.8% vs. 71.5 {+-} 6.7%; p < 0.0005). Among responders, those who achieved nPSA <0.5 ng/mL in {<=}5 years had higher FFBF than those requiring >5 years (5-year FFBF: 96.7 {+-} 0.7% vs. 80.8 {+-} 4.6%; p < 0.0005). On multivariate analysis, patients who achieved nPSA <0.5 ng/mL in {<=}5 years had significantly higher FFBF than other

  15. Synkavit and its direct labelling with iodine-125, as a potential anti-cancer drug

    International Nuclear Information System (INIS)

    Unak, T.; Unak, P.

    1993-01-01

    The compound known as ''synkavit'' is a diphosphate derivative of vitamin K 3 (menadion), which is capable of being selectively accumulated in certain tumour cells, and covalently bonded to DNA producing considerable DNA damage. On the other hand, iodine-125 nuclide incorporated into the nucleus of living cells causes extreme radiotoxic effects. Consequently, synkavit can be used as a specific carrier of iodine-125 into the nucleus of tumour cells. Thus, its iodo-derivatives have become interesting agents on the potential application of iodine-125 in cancer therapy. 6-Iodo-synkavit is a unique iodo-derivative described in the literature. In addition, its synthesis and radioiodination is still problematic, and consequently the results obtained using 6-iodo-synkavit labelled with iodine-125 remains in question. For this reason, the synthesis of 6-iodo-synkavit was examined in this study. It is finally determined that a mixture of different iodo-isomers of synkavit has been produced rather than its specific 6-iodo-isomer, when the synthetic sequence was begun with the direct sulfonation of 2-methyl-naphthalene. On the other hand, it is also determined that synkavit can directly be radioiodinated using different iodination techniques, and iodogen especially can be successfully used as an oxidative agent. (Author)

  16. SU-E-J-181: Effect of Prostate Motion On Combined Brachytherapy and External Beam Dose Based On Daily Motion of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Narayana, V; McLaughlin, P [Providence Cancer Center, Southfield, MI (United States); University of Michigan, Ann Arbor, MI (United States); Ealbaj, J [University of Michigan, Ann Arbor, MI (United States)

    2015-06-15

    Purpose: In this study, the adequacy of target expansions on the combined external beam and implant dose was examined based on the measured daily motion of the prostate. Methods: Thirty patients received an I–125 prostate implant prescribed to dose of 90Gy. This was followed by external beam to deliver a dose of 90Gyeq (external beam equivalent) to the prostate over 25 to 30 fractions. An ideal IMRT plan was developed by optimizing the external beam dose based on the delivered implant dose. The implant dose was converted to an equivalent external beam dose using the linear quadratic model. Patients were set up on the treatment table by daily orthogonal imaging and aligning the marker seeds in the prostate. Orthogonal images were obtained at the end of treatment to assess prostate intrafraction motion. Based on the observed motion of the markers between the initial and final images, 5 individual plans showing the actual dose delivered to the patient were calculated. A final true dose distribution was established based on summing the implant dose and the 5 external beam plans. Dose to the prostate, seminal vesicles, lymphnodes and normal tissues, rectal wall, urethra and lower sphincter were calculated and compared to ideal. On 18 patients who were sexually active, dose to the corpus cavernosum and internal pudendal artery was also calculated. Results: The average prostate motion in 3 orthogonal directions was less than 1 mm with a standard deviation of less than +2 mm. Dose and volume parameters showed that there was no decrease in dose to the targets and a marginal decrease in dose to in normal tissues. Conclusion: Dose delivered by seed implant moves with the prostate, decreasing the impact of intrafractions dose movement on actual dose delivered. Combined brachytherapy and external beam dose delivered to the prostate was not sensitive to prostate motion.

  17. Androgen-deprivation therapy does not impact cause-specific or overall survival after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Galbreath, Robert W.; Allen, Zachariah A. M.S.; Adamovich, Edward

    2006-01-01

    Purpose: To determine if androgen-deprivation therapy (ADT) has an impact on cause-specific, biochemical progression-free, or overall survival after prostate brachytherapy. Methods and Materials: From April 1995 through June 2002, 938 consecutive patients underwent brachytherapy for clinical Stage T1b to T3a (2002 AJCC) prostate cancer. All patients underwent brachytherapy more than 3 years before analysis. A total of 382 patients (40.7%) received ADT with a duration of 6 months or less in 277 and more than 6 months in 105. The median follow-up was 5.4 years. Multiple clinical, treatment, and dosimetric parameters were evaluated as predictors of cause-specific, biochemical progression-free, and overall survival. Results: The 10-year cause-specific, biochemical progression-free, and overall survival rates for the entire cohort were 96.4%, 95.9%, and 78.1%, respectively. Except for biochemical progression-free survival in high-risk patients, ADT did not statistically impact any of the three survival categories. A Cox linear-regression analysis demonstrated that Gleason score was the best predictor of cause-specific survival, whereas percent-positive biopsies, prostate volume, and risk group predicted for biochemical progression-free survival. Patient age and tobacco use were the strongest predictors of overall survival. One hundred two patients have died, with 80 of the deaths a result of cardiovascular disease (54) and second malignancies (26). To date, only 12 patients have died of metastatic prostate cancer. Conclusions: After brachytherapy, androgen-deprivation therapy did not have an impact on cause-specific or overall survival for any risk group; however, ADT had a beneficial effect on biochemical progression-free survival in high-risk patients. Cardiovascular disease and second malignancies far outweighed prostate cancer as competing causes of death

  18. Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fox, C. D.; Kron, T.; Leahy, M.; Duchesne, G.; Williams, S.; Tai, K. H.; Haworth, A.; Herschtal, A.; Foroudi, F. [Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Nursing Service, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Department of Radiation Oncology, Peter MacCallum Cancer Centre and University of Melbourne, Melbourne, Victoria 3002 (Australia); Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Insititute of Technology, Melbourne, Victoria 3000 (Australia); Department of Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Department of Radiation Oncology, Peter MacCallum Cancer Centre and University of Melbourne, Melbourne, Victoria 3010 (Australia)

    2011-11-15

    Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

  19. Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Fox, C. D.; Kron, T.; Leahy, M.; Duchesne, G.; Williams, S.; Tai, K. H.; Haworth, A.; Herschtal, A.; Foroudi, F.

    2011-01-01

    Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

  20. Fast prostate segmentation for brachytherapy based on joint fusion of images and labels

    Science.gov (United States)

    Nouranian, Saman; Ramezani, Mahdi; Mahdavi, S. Sara; Spadinger, Ingrid; Morris, William J.; Salcudean, Septimiu E.; Abolmaesumi, Purang

    2014-03-01

    Brachytherapy as one of the treatment methods for prostate cancer takes place by implantation of radioactive seeds inside the gland. The standard of care for this treatment procedure is to acquire transrectal ultrasound images of the prostate which are segmented in order to plan the appropriate seed placement. The segmentation process is usually performed either manually or semi-automatically and is associated with subjective errors because the prostate visibility is limited in ultrasound images. The current segmentation process also limits the possibility of intra-operative delineation of the prostate to perform real-time dosimetry. In this paper, we propose a computationally inexpensive and fully automatic segmentation approach that takes advantage of previously segmented images to form a joint space of images and their segmentations. We utilize joint Independent Component Analysis method to generate a model which is further employed to produce a probability map of the target segmentation. We evaluate this approach on the transrectal ultrasound volume images of 60 patients using a leave-one-out cross-validation approach. The results are compared with the manually segmented prostate contours that were used by clinicians to plan brachytherapy procedures. We show that the proposed approach is fast with comparable accuracy and precision to those found in previous studies on TRUS segmentation.

  1. A theoretical derivation of the nomograms for permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Wang Xiaohong; Potters, Louis

    2001-01-01

    This study calculates the required minimum radioactivity to deliver a prescribed dose of radiation to a target using radioisotopes in permanent prostate brachytherapy. Assuming the radioactivity to be in a continuous form, an integral equation -- Fredholm equation of the first kind, can be formulated with the radioactivity density used as the variable. The density distribution to produce a uniform volume dose rate is determined using a quadrature method and the radial profile behaves smoothly from the zero radius, and peaks sharply approaching the volume boundary. The density for Pd-103 is about 1.5 times that of I-125 due to its higher spatial attenuation. A nomogram is the relationship between the total activity per unit dose (A) and the dimension of the volume (d). Expressing the nomogram as A=cxd n U/Gy, then (c,n)= [(0.0098, 2.09) I-125] and [(0.031, 2.25) Pd-103]. Compared with the Memorial nomogram, (c,n)=[(0.011,2.2) I-125] and [(0.036,2.56) Pd-103], or that quoted by AAPM TG64, (c,n)=[(0.014,2.05) I-125] and [(0.056,2.22) Pd-103], our calculation determined an average 33% and 35% decrease for I-125, and 89% and 77% decrease for Pd-103, respectively. Two reasons for the extra total activity found in the Memorial and AAPM nomograms are: (a) An imperfect clinical situation limited by the restraints of implant techniques (e.g., use of templates) associated with the presence of adjacent normal organs, and (b) source discretization into seeds. When radioactivity is clumped as discrete seeds, higher activity is needed because of 'wastage' in two aspects: (a) Dose cold-spots at intersource spaces, (b) hot-spots around the sources. Thus in theory, use of lower activity seeds will require less total activity to deliver a prescribed dose. Based on our study, Pd-103 delivers a higher therapeutic ratio and a lower integral dose to the patient compared to I-125

  2. Isodose curves recorded in radiochromic film of an iodine seed array

    International Nuclear Information System (INIS)

    Mourao, Arnaldo Prata; Tomaz, Lucas Crusoe; Grynberg, Suely Epzstein

    2015-01-01

    Brachytherapy seeds are frequently used in cancer treatment. Iodine seeds are ranked among the top choices when it comes to the treatment of prostate cancer. Iodine-125 emits X and gamma photons with an average energy of 28 keV and a half-life of 59.4 days. A set of four iodine-125 seeds, model 6711 produced by Amersham Health, were used in this work. The dosimetric characteristics for a seed were obtained taking into account the recommendations of TG-43 protocol, developed by the AAPM (American Association of Physicists in Medicine). To realize the experiment three plates of Standard Grade Solid Water, model 457 ® Gammex were used. One solid water plate was machined for accommodate the seed set. The set of seeds was placed in a symmetrical configuration trying to simulate an arrangement which may occur in vivo during treatment. A radiochromic film sheet was placed on the plate machined after the seed charge. The machined plate charged and with the film sheet was placed between two others solid water plate to recorder the radiation dose. The machined plate was placed between the other two plates for better reliability in measurements. The radio chromic film was irradiated by an equivalent X-ray beam using the reference radiation RQR 3 IEC (International Electrotechnical Commission) with different doses (0.5 to 1.0 Gy) to obtain the calibration curve in the dose region measured. After validation of the methodology, the study of the interaction between the radiation fields of the set of seeds became possible and the survey of isodose curves of these setting was conducted. (author)

  3. Multi-atlas-based automatic 3D segmentation for prostate brachytherapy in transrectal ultrasound images

    Science.gov (United States)

    Nouranian, Saman; Mahdavi, S. Sara; Spadinger, Ingrid; Morris, William J.; Salcudean, S. E.; Abolmaesumi, P.

    2013-03-01

    One of the commonly used treatment methods for early-stage prostate cancer is brachytherapy. The standard of care for planning this procedure is segmentation of contours from transrectal ultrasound (TRUS) images, which closely follow the prostate boundary. This process is currently performed either manually or using semi-automatic techniques. This paper introduces a fully automatic segmentation algorithm which uses a priori knowledge of contours in a reference data set of TRUS volumes. A non-parametric deformable registration method is employed to transform the atlas prostate contours to a target image coordinates. All atlas images are sorted based on their registration results and the highest ranked registration results are selected for decision fusion. A Simultaneous Truth and Performance Level Estimation algorithm is utilized to fuse labels from registered atlases and produce a segmented target volume. In this experiment, 50 patient TRUS volumes are obtained and a leave-one-out study on TRUS volumes is reported. We also compare our results with a state-of-the-art semi-automatic prostate segmentation method that has been clinically used for planning prostate brachytherapy procedures and we show comparable accuracy and precision within clinically acceptable runtime.

  4. Comparison of seed brachytherapy or external beam radiotherapy (70 Gy or 74 Gy) in 919 low-risk prostate cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Goldner, G.; Poetter, R.; Schmid, M.P.; Kirisits, C. [University Hospital of Vienna (Austria). Dept. of Radiotherapy and Radiobiology; Battermann, J.J.; Sljivic, S.; Vulpen, M. van [University Medical Center Utrecht (Netherlands). Dept. of Radiation Oncology

    2012-04-15

    The aim of this analysis was to compare the biochemical no evidence of disease (bNED) rates in low-risk prostate cancer patients treated at two centers of excellence using different approaches: seed brachytherapy (BT) and external beam radiotherapy (EBRT). Materials and methods: A total of 919 low-risk prostate cancer patients, treated from 1998-2008, were identified in the two databases. In Utrecht, 667 patients received I-125 BT applying a dose of 144 Gy. In Vienna, 252 patients were treated with EBRT, applying a local dose of 70 Gy in 82 patients and 74 Gy in 170 patients. bNED rates (Phoenix definition) were assessed. Results: The median follow-up was 46 months (range 1-148 months). The 5-year actuarial bNED rates were 94% for BT patients and 88% for EBRT patients (p = 0.002) - 84% for patients receiving 70 Gy and 91% for patients receiving 74 Gy, respectively. In the univariate analysis, patients receiving 70 Gy showed significantly worse outcome compared to BT (p = 0.001) and a difference close to significance compared to 74 Gy (p = 0.06). In the multivariate analysis including tumor stage, Gleason score, initial PSA, hormonal therapy, and dose, patients receiving 70 Gy EBRT showed significantly worse bNED rates compared to BT patients. Conclusion: Low-risk prostate cancer patients receiving 74 Gy by EBRT show comparable biochemical control rates to patients receiving seed brachytherapy, whereas patients receiving 70 Gy show significantly worse outcome. (orig.)

  5. Efficacy of 2.5 percent and 1.25 percent Povidone-Iodine Solution for Prophylaxis of Ophthalmia Neonatorum

    International Nuclear Information System (INIS)

    Khan, F. A.; Hussain, M. A.; Niazi, S. P. K.; Haq, Z. U.; Akhtar, N.

    2016-01-01

    Objective: To determine the efficacy of 2.5 percentage and 1.25 percentage Povidone-Iodine solution for Ophthalmia neonatorum prophylaxis. Study Design: Interventional study. Place and Duration of Study: Eye Department, Combined Military Hospital, Sargodha, from May to November 2014. Methodology: A total of 200 eyes of 100 newborn babies were enrolled and divided into two groups of 100 right eyes and 100 left eyes. A conjunctival swab for bacterial culture was taken within 30 minutes after delivery. A single drop of 2.5 percentage Povidone-Iodine was then placed in the right eye while in the left eye a single drop of 1.25 percentage Povidone-Iodine was placed. Thirty minutes after placing Povidone-Iodine, a conjunctival swab was again taken. A bacterial suspension was prepared from each swab in determining bacterial counts. The bacterial suspension was inoculated on yeast extract agar and the number of colony forming units were counted. At each culture, the number of colony forming units before and after instillation of 2.5 percentage Povidone-Iodine and 1.25 percentage Povidone-Iodine were compared. Wilcoxon's signed rank test was used for statistical analysis. Results: The 2.5 percentage Povidone-Iodine solution caused a statistically significant decrease in the number of colony forming units (p=0.001). Similarly, the 1.25 percentage Povidone-Iodine solution also reduced the number of colony forming units to a statistically significant level (p=0.001). Conclusion: The 1.25 percentage concentration of Povidone-Iodine is as effective as the 2.5 percentage concentration of Povidone-Iodine in reducing the number of colony forming units in healthy conjunctivae of newborns. (author)

  6. Temporal resolution of urinary morbidity following prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Lief, Jonathan H.; Dorsey, Anthony T.

    2000-01-01

    Purpose: To report the short-term urinary morbidity for prostate brachytherapy patients without a preimplant history of a transurethral resection of the prostate gland and who received prophylactic and prolonged α-blockers. α-blockers may decrease radiation-induced urethritis and increase urinary flow. Multiple clinical and treatment parameters were evaluated to identify factors associated with increased acute urinary morbidity. Materials and Methods: One hundred seventy consecutive patients without a prior history of a transurethral resection of the prostate gland underwent transperineal ultrasound guided prostate brachytherapy for clinical T1c-T3a carcinoma of the prostate gland. For all patients, an α-blocker was initiated prior to implantation and continued at least until the international prostate symptom score (IPSS) returned to baseline levels. Clinical parameters evaluated for short-term urinary morbidity included patient age, clinical T stage, preimplant IPSS (obtained within 3 weeks of implantation), and prostate ultrasound volume. Treatment parameters included the utilization of neoadjuvant hormonal manipulation, the utilization of moderate dose external beam radiation therapy before implantation, the choice of isotope, the urethral dose, the total implant activity in millicuries, and a variety of dosimetric quality indicators (D 90 and V 100 /V 150 /V 200 ). Catheter dependency and the duration of α-blocker dependency was also evaluated. On average, 11.2 IPSS surveys were obtained for each patient. Results: One hundred fifty of the 170 patients (88.2%) had the urinary catheter permanently removed on day 0. Only one patient required an urinary catheter for > 5 days. Two patients (1.2%) required a subsequent transurethral resection of the prostate gland because of prolonged obstructive/irritative symptoms. To date, no patient has developed an urinary stricture or urinary incontinence. The IPS score on average peaked at 2 weeks following implantation

  7. American Society for Radiation Oncology (ASTRO) and American College of Radiology (ACR) Practice Guideline for the Transperineal Permanent Brachytherapy of Prostate Cancer

    International Nuclear Information System (INIS)

    Rosenthal, Seth A.; Bittner, Nathan H.J.; Beyer, David C.; Demanes, D. Jeffrey; Goldsmith, Brian J.; Horwitz, Eric M.; Ibbott, Geoffrey S.; Lee, W. Robert; Nag, Subir; Suh, W. Warren; Potters, Louis

    2011-01-01

    Transperineal permanent prostate brachytherapy is a safe and efficacious treatment option for patients with organ-confined prostate cancer. Careful adherence to established brachytherapy standards has been shown to improve the likelihood of procedural success and reduce the incidence of treatment-related morbidity. A collaborative effort of the American College of Radiology (ACR) and American Society for Therapeutic Radiation Oncology (ASTRO) has produced a practice guideline for permanent prostate brachytherapy. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist and dosimetrist. Factors with respect to patient selection and appropriate use of supplemental treatment modalities such as external beam radiation and androgen suppression therapy are discussed. Logistics with respect to the brachtherapy implant procedure, the importance of dosimetric parameters, and attention to radiation safety procedures and documentation are presented. Adherence to these practice guidelines can be part of ensuring quality and safety in a successful prostate brachytherapy program.

  8. Needle displacement during HDR brachytherapy in the treatment of prostate cancer

    International Nuclear Information System (INIS)

    Damore, Steven J.; Syed, A.M. Nisar; Puthawala, Ajmel A.; Sharma, Anil

    2000-01-01

    Purpose: We used clinical patient data to examine implant displacement between high dose rate (HDR) brachytherapy fractions for prostate cancer to determine its impact on treatment delivery. Materials and Methods: We analyzed the verification films taken prior to each fraction for 96 consecutive patients treated with HDR brachytherapy boosts as part of their radiation therapy for definitive treatment of organ-confined prostate cancer at our institution. Patients were treated with 18-24 Gy in 4 fractions of HDR delivered in 40 hours followed by 36-39.6 Gy external beam radiation to the prostate. We determined the mean and maximum displacement distances of marker seeds placed in the prostate and of the implanted needles between HDR fractions. Results: Mean and maximum displacement distances between fractions were documented up to 7.6 mm and 28.5 mm, respectively, for the implant needles and 3.6 mm and 11.4 mm, respectively, for the gold marker seeds. All displacement of implant needles occurred in the caudal direction. At least 1 cm caudal displacement of needles occurred prior to 15.5% all fractions. Manual adjustment of needles was required prior to 15% of fractions, and adjustment of the CLP only was required in 24%. Most of the displacement for both the marker seeds and needles occurred between the first and second fractions. Conclusions: There is significant caudal displacement of interstitial implant needles between HDR fractions in our prostate cancer patients. Obtaining verification films and making adjustments in the treatment volume prior to each fraction is necessary to avoid significant inaccuracies in treatment delivery

  9. Definition of medical event is to be based on the total source strength for evaluation of permanent prostate brachytherapy: A report from the American Society for Radiation Oncology.

    Science.gov (United States)

    Nag, Subir; Demanes, D Jeffrey; Hagan, Michael; Rivard, Mark J; Thomadsen, Bruce R; Welsh, James S; Williamson, Jeffrey F

    2011-10-01

    The Nuclear Regulatory Commission deems it to be a medical event (ME) if the total dose delivered differs from the prescribed dose by 20% or more. A dose-based definition of ME is not appropriate for permanent prostate brachytherapy as it generates too many spurious MEs and thereby creates unnecessary apprehension in patients, and ties up regulatory bodies and the licensees in unnecessary and burdensome investigations. A more suitable definition of ME is required for permanent prostate brachytherapy. The American Society for Radiation Oncology (ASTRO) formed a working group of experienced clinicians to review the literature, assess the validity of current regulations, and make specific recommendations about the definition of an ME in permanent prostate brachytherapy. The working group found that the current definition of ME in §35.3045 as "the total dose delivered differs from the prescribed dose by 20 percent or more" was not suitable for permanent prostate brachytherapy since the prostate volume (and hence the resultant calculated prostate dose) is dependent on the timing of the imaging, the imaging modality used, the observer variability in prostate contouring, the planning margins used, inadequacies of brachytherapy treatment planning systems to calculate tissue doses, and seed migration within and outside the prostate. If a dose-based definition for permanent implants is applied strictly, many properly executed implants would be improperly classified as an ME leading to a detrimental effect on brachytherapy. The working group found that a source strength-based criterion, of >20% of source strength prescribed in the post-procedure written directive being implanted outside the planning target volume is more appropriate for defining ME in permanent prostate brachytherapy. ASTRO recommends that the definition of ME for permanent prostate brachytherapy should not be dose based but should be based upon the source strength (air-kerma strength) administered.

  10. Salvage brachytherapy for local recurrences of prostate cancer treated previously with radiotherapy.

    Science.gov (United States)

    Gawkowska-Suwinska, Marzena; Fijałkowski, Marek; Białas, Brygida; Szlag, Marta; Kellas-Ślęczka, Sylwia; Nowicka, Elżbieta; Behrendt, Katarzyna; Plewicki, Grzegorz; Smolska-Ciszewska, Beata; Giglok, Monika; Zajusz, Aleksander; Owczarek, Grzegorz

    2009-12-01

    The aim of the study was to analyze early effects and toxicity of salvage high dose rate brachytherapy for local recurrences of adenocarcinoma of the prostate after external beam radiotherapy (EBRT). In MCS Memorial Institute of Oncology in Gliwice a research programme on salvage HDR brachytherapy for local recurrences of prostate cancer treated previously with EBRT has been ongoing since February 2008. The treatment consisted of 3 fractions of 10 Gy each given every 14 days. Maximal urethral doses were constrained to be ≤ 120% of the prescribed dose. Maximal bladder and rectum doses were constrained to be ≤ 70% of the prescribed dose. Fifteen eligible patients were treated and analyzed from February 2008. All patients completed the treatment without major complications. The most common early complications were: macroscopic haematuria, pain in lower part of the abdomen, and transient dysuria. During the first week after the procedure a transient increase in IPSS score was noticed. The Foley catheter was removed on day 2 to 5. No complications after spinal anaesthesia were observed. Acute toxicity according to EORTC/RTOG was low. For bladder EORTC/RTOG score ranged from 0 to 2. Only in two patients grade 1 toxicity for rectum was observed. The follow-up ranged from 3 to 9 months. In one patient grade 2 rectal toxicity was observed, and one had urethral stricture. Other patients did not have any other significant late toxicity of the treatment. Two patients developed bone metastases. Salvage brachytherapy for localized prostate cancer (3 × 10 Gy every 14 days) seems to be a safe and well tolerated procedure. A significant decline in prostate-specific antigen (PSA) level is seen in patients with hormone-responsive cancer. Long-term efficiency and toxicity of the procedure are yet to be established.

  11. MO-B-BRC-01: Introduction [Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Prisciandaro, J. [University of Michigan (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  12. Meta-analysis of comparison between brachytherapy and radical prostatectomy for the treatment of localized prostate cancer

    International Nuclear Information System (INIS)

    Fan Xiaodong; Jiang Qing; Yuan Gengbiao; Wang Jiawu

    2012-01-01

    Objective: To compare the therapeutic effect of brachytherapy and radical prostatectomy for localized prostate cancer using a Meta-analysis. Methods: The published data with randomized control trials (RCT) on comparison of brachytherapy and radical prostatectomy for the treatment of localized prostate cancer in PubMed, Wanfang database, Chinese Biomedical Literature Database (CBMdisc), the Excerpta Medica Database (EMBASE), Ovid and Cochrane library were searched and screened. The quality of the studies included was evaluated and the data with 5-year event free survival rate for comparison were extracted. Meta-analysis was performed by RevMan 5.0 (Cochrane reviews software). Results: From six trials, there were 5903 patients that were eligible for the analysis, in which 3323 patients were treated by brachytherapy and other 2580 by radical prostatectomy. The odds ratio of all trials was 1.00 (95% CI: 0.69-1.45, P=0.99) and there was no significant difference of 5-year event free survival rate between two treatment groups. Conclusion: This Meta analysis shows that brachytherapy may have comparable treatment effect than radical prostatectomy. (authors)

  13. High-dose rate brachytherapy in the treatment of prostate cancer: acute toxicity and biochemical behavior analysis

    International Nuclear Information System (INIS)

    Esteves, Sergio Carlos Barros; Oliveira, Antonio Carlos Zuliani de; Cardoso, Herbeni; Tagawa, Eduardo Komai; Castelo, Roberto; D'Imperio, Marcio

    2006-01-01

    Objective: this study focuses on the biochemical response of the following variables: prostate volume, prostate-specific antigen (PSA) value, Gleason scores, staging, the risk of the disease, and hormone therapy. Objective: in the period between February of 1998 and July of 2001, 46 patients with prostate cancer were treated with radiotherapy, in a combination of teletherapy and high-dose rate (HDR) brachytherapy. The age ranged from 51 to 79 years (averaging 66.4 years). T1c stage was the most frequent one: 30 (65%). The Gleason score was below 7 in 78% of the patients. PSA ranged from 3.4 to 33.3, being below 10 in 39% of the cases. The average prostatic volume was 32.3 cc. Twenty-eight percent of the patients received hormone therapy. Teletherapy dose ranged from 45 to 50.4 Gy, associated to four fractions of 4 Gy of HDR brachytherapy. Results: the follow-up period varied from 6 to 43 months. Four patients missed the follow-up and four died (one due to the disease). Out of the 39 patients that were analyzed, 76% presented a less than 1.5 PSA. None of the analyzed variables were found to be of statistical significance (p > 0.05) regarding biochemical control. Conclusion: the use of HDR brachytherapy was found to be effective in the treatment of prostate cancer and, in this study, the variables considered as prognostic factors did not interfere in the biochemical control. (author)

  14. The use of nomograms in LDR-HDR prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Ma Carmen Pujades

    2011-09-01

    Full Text Available Purpose: The common use of nomograms in Low Dose Rate (LDR permanent prostate brachytherapy (BT allowsto estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for eachclinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adaptedto High Dose Rate (HDR. This work sets nomograms for LDR and HDR prostate-BT implants, which are applied tothree different institutions that use different implant techniques. Material and methods: Patients treated throughout 2010 till April 2011 were considered for this study. This examplewas chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficientnumber of cases for both BT modalities, prescription dose and different work methodology (depending on theinstitution were taken into account. The specific nomograms were built using the correlation between the prostatevo lume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, numberof implanted seeds in LDR or total radiation time in HDR. Results: For each institution and BT modality, nomograms normalized to the prescribed dose were obtained andfitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting.It should be noted that for each institution these linear function parameters are different, indicating that each centreshould construct its own nomograms. Conclusions: Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific foreach institution. Nevertheless, their use should be complementary to the necessary independent verification.

  15. Tratamento conservador ocular dos melanomas de coróide com braquiterapia utilizando placas de iodo-125 Conservative treatment of choroidal melanomas using iodine brachytherapy

    Directory of Open Access Journals (Sweden)

    Antônio Cássio Assis Pellizzon

    2004-08-01

    Full Text Available OBJETIVO: Avaliar, retrospectivamente, o resultado do tratamento conservador do melanoma de coróide, por meio de braquiterapia, usando placas episclerais de iodo-125 (modelo 6711, Amershan. MATERIAIS E MÉTODOS: Foram avaliados 49 pacientes portadores de melanoma de coróide tratados no Hospital do Câncer, São Paulo, SP, de março de 2001 a janeiro de 2003. Os seguintes parâmetros foram analisados e correlacionados ao controle local e sobrevida: sexo, idade, dimensões da lesão, tempo de tratamento e doses no ápice e base das lesões. RESULTADOS: Com diâmetro máximo da base do tumor de 17 mm e altura máxima de 12 mm, observamos que as doses na base do tumor variaram de 213 a 463 Gy (mediana de 347 Gy e no ápice, de 51 a 250 Gy (mediana de 91 Gy. As taxas de preservação ocular, sobrevida livre de doença e conservação ocular, atuariais em dois anos, foram de 96%, 93,5% e 96,3%, respectivamente. Através de análise univariada, o único fator prognóstico para controle local nesta análise foi a altura do tumor menor que 6 mm (p = 0,0348. CONCLUSÃO: A braquiterapia levou a uma taxa bastante satisfatória de controle local, confirmando que a altura do tumor é um dos fatores prognósticos importantes desse parâmetro.OBJECTIVE: To retrospectively evaluate the results of conservative therapy using episcleral iodine-125 (model 6711, Amershan plaque for brachytherapy of choroidal melanoma. MATERIALS AND METHODS: We evaluated 49 patients with choroidal melanoma treated at "Hospital do Câncer", São Paulo, Brazil, from March 2001 to January 2003. The following clinical parameters were analyzed and correlated with local control and survival rate: gender, age, lesion dimension, treatment duration, as well as doses in apex and base of the tumors. RESULTS: The maximum diameter and height of the base of the tumors treated were 17 mm and 12 mm, respectively. Doses at those points ranged from 213 to 463 Gy (median: 347 Gy and 51 to 250 Gy

  16. Iodine-125 safety procedures in a biochemical laboratory

    International Nuclear Information System (INIS)

    1989-01-01

    Radioactive isotopes of iodine are of considerable importance in biochemical research and this 14 minute videotape is designed to give workers an introduction to the radiation safety aspects of their use. It deals with I-125, which is now generally used in preference to I-131, but the principles of safe working practice are the same for both isotopes. (author)

  17. Dosimetric comparison of interactive planned and dynamic dose calculated prostate seed brachytherapy

    International Nuclear Information System (INIS)

    Meijer, Gert J.; Berg, Hetty A. van den; Hurkmans, Coen W.; Stijns, Pascal E.; Weterings, Jan H.

    2006-01-01

    Purpose: To compare the dosimetrical results of an interactive planning procedure and a procedure based on dynamic dose calculation for permanent prostate brachytherapy. Materials and methods: Between 6/2000 and 11/2005, 510 patients underwent 125 I implants for T1-T2 prostate cancer. Before 4/2003, 187 patients were treated using an interactive technique that included needle updating. After that period, 323 patients were treated with a more refined dynamic technique that included constant updating of the deposited seed position. The comparison is based on postimplant dose-volume parameters such as the V 100 and d 90 for the target, V 100 r for the rectum and d 10 u for the urethra. Furthermore, the target volume ratios (TVR=V 100 body /V 100 ), and the homogeneity indices (HI=[V 100 -V 150 ]/V 100 ) were calculated as additional quality parameters. Results: The dose outside the target volume was significantly reduced, the V 100 r decreased from 1.4cm 3 for the interactive technique to 0.6cm 3 for the dynamic technique. Similarly the mean TVR reduced from 1.66 to 1.44. In addition, the mean V 100 increased from 92% for the interactive procedure to 95% for the dynamic procedure. More importantly, the percentage of patients with a V 100 10 u (136% vs. 140%) and the HI (0.58 vs. 0.51). Conclusion: The dynamic implant procedure resulted in improved implants. Almost ideal dose coverage was achieved, while minimizing the dose outside the prostate

  18. Dosimetric results in implant and post-implant and low rate in brachytherapy prostate cancer with loose seeds and attached; Resultados dosimetricos en el implante y post-impante en braquiterapia de baja tasa en cancer de prostata con semillas sueltas y unidas

    Energy Technology Data Exchange (ETDEWEB)

    Juan-Senabre, X. J.; Albert Antequera, M.; Lopez-Tarjuelo, J.; Santos Serra, A.; Perez-Mestre, M.; Sanchez Iglesias, A. L.; Conde Moreno, A. J.; Gonzalez Vidal, V.; Beltran Persiva, J.; Muelas Soria, R.; Ferrer Albiach, C.

    2015-07-01

    The objective is determine differences dosimetry statistics on the dosimetry of the implant and post-implant in brachytherapy of low rate with implants permanent in prostate using seed of 125-I loose and attached Both in lives and in the post-prostatic plans dosimetric coverage is good and restrictions in urethra and rectum for both groups of patients are met. Not migrating with joined is evident, as well as better dosimetric homogeneity. (Author)

  19. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  20. 3-D conformal HDR brachytherapy as monotherapy for localized prostate cancer. A pilot study

    International Nuclear Information System (INIS)

    Martin, T.; Baltas, D.; Kurek, R.; Roeddiger, S.; Kontova, M.; Anagnostopoulos, G.; Skazikis, G.; Zamboglou, N.; Dannenberg, T.; Buhleier, T.; Tunn, U.

    2004-01-01

    Purpose: pilot study to evaluate feasibility, acute toxicity and conformal quality of three-dimensional (3-D) conformal high-dose-rate (HDR) brachytherapy as monotherapy for localized prostate cancer using intraoperative real-time planning. Patients and methods: between 05/2002 and 05/2003, 52 patients with prostate cancer, prostate-specific antigen (PSA) ≤ 10 ng/ml, Gleason score ≤ 7 and clinical stage ≤ T2a were treated. Median PSA was 6.4 ng/ml and median Gleason score 5. 24/52 patients had stage T1c and 28/52 stage T2a. For transrectal ultrasound-(TRUS-)guided transperineal implantation of flexible plastic needles into the prostate, the real-time HDR planning system SWIFT trademark was used. After implantation, CT-based 3-D postplanning was performed. All patients received one implant for four fractions of HDR brachytherapy in 48 h using a reference dose (D ref ) of 9.5 Gy to a total dose of 38.0 Gy. Dose-volume histograms (DVHs) were analyzed to evaluate the conformal quality of each implant using D 90 , D 10 urethra, and D 10 rectum. Acute toxicity was evaluated using the CTC (common toxicity criteria) scales. Results: median D 90 was 106% of D ref (range: 93-115%), median D 10 urethra 159% of D ref (range: 127-192%), and median D 10 rectum 55% of D ref (range: 35-68%). Median follow-up is currently 8 months. In 2/52 patients acute grade 3 genitourinary toxicity was observed. No gastrointestinal toxicity > grade 1 occurred. Conclusion: 3-D conformal HDR brachytherapy as monotherapy using intraoperative real-time planning is a feasible and highly conformal treatment for localized prostate cancer associated with minimal acute toxicity. Longer follow-up is needed to evaluate late toxicity and biochemical control. (orig.)

  1. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  2. Long-Term Results of an RTOG Phase II Trial (00-19) of External-Beam Radiation Therapy Combined With Permanent Source Brachytherapy for Intermediate-Risk Clinically Localized Adenocarcinoma of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, Colleen A., E-mail: clawton@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Yan, Yan [Radiation Therapy Oncology Group Statistical Center, Philadelphia, PA (United States); Lee, W. Robert [Department of Radiation Oncology, Duke University School of Medicine, Durham, NC (United States); Gillin, Michael [Department of Radiation Oncology, MD Anderson Cancer Center, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Firat, Selim [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Baikadi, Madhava [Department of Radiation Oncology, Northeast Radiation Oncology Center, Scranton, PA (United States); Crook, Juanita [Department of Radiation Oncology, University of British Columbia, Kelowna, BC (Canada); Kuettel, Michael [Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY (United States); Morton, Gerald [Department of Radiation Oncology, Toronto-Sunnybrook Regional Cancer Center, Toronto, ON (Canada); Sandler, Howard [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, CA (United States)

    2012-04-01

    Purpose: External-beam radiation therapy combined with low-doserate permanent brachytherapy are commonly used to treat men with localized prostate cancer. This Phase II trial was performed to document late gastrointestinal or genitourinary toxicity as well as biochemical control for this treatment in a multi-institutional cooperative group setting. This report defines the long-term results of this trial. Methods and Materials: All eligible patients received external-beam radiation (45 Gy in 25 fractions) followed 2-6 weeks later by a permanent iodine 125 implant of 108 Gy. Late toxicity was defined by the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late radiation morbidity scoring scheme. Biochemical control was defined by the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus definition and the ASTRO Phoenix definition. Results: One hundred thirty-eight patients were enrolled from 20 institutions, and 131 were eligible. Median follow-up (living patients) was 8.2 years (range, 2.7-9.3 years). The 8-year estimate of late grade >3 genitourinary and/or gastrointestinal toxicity was 15%. The most common grade >3 toxicities were urinary frequency, dysuria, and proctitis. There were two grade 4 toxicities, both bladder necrosis, and no grade 5 toxicities. In addition, 42% of patients complained of grade 3 impotence (no erections) at 8 years. The 8-year estimate of biochemical failure was 18% and 21% by the Phoenix and ASTRO consensus definitions, respectively. Conclusion: Biochemical control for this treatment seems durable with 8 years of follow-up and is similar to high-dose external beam radiation alone or brachytherapy alone. Late toxicity in this multi-institutional trial is higher than reports from similar cohorts of patients treated with high-dose external-beam radiation alone or permanent low-doserate brachytherapy alone, perhaps suggesting further attention to strategies that limit doses to

  3. Dosimetric study of prostate brachytherapy using techniques of Monte-Carlo simulation, experimental measurements and comparison with a treatment plan

    International Nuclear Information System (INIS)

    Teles, Pedro; Barros, Silvia; Vaz, Pedro; Goncalves, Isabel; Facure, Alessandro; Rosa, Luiz da; Santos, Maira; Pereira Junior, Pedro Paulo; Zankl, Maria

    2013-01-01

    Prostate Brachytherapy is a radiotherapy technique, which consists in inserting a number of radioactive seeds (containing, usually, the following radionuclides 125 l, 241 Am or 103 Pd ) surrounding or in the vicinity of, prostate tumor tissue . The main objective of this technique is to maximize the radiation dose to the tumor and minimize it in other tissues and organs healthy, in order to reduce its morbidity. The absorbed dose distribution in the prostate, using this technique is usually non-homogeneous and time dependent. Various parameters such as the type of seed, the attenuation interactions between them, their geometrical arrangement within the prostate, the actual geometry of the seeds,and further swelling of the prostate gland after implantation greatly influence the course of absorbed dose in the prostate and surrounding areas. Quantification of these parameters is therefore extremely important for dose optimization and improvement of their plans conventional treatment, which in many cases not fully take into account. The Monte Carlo techniques allow to study these parameters quickly and effectively. In this work, we use the program MCNPX and generic voxel phantom (GOLEM) where simulated different geometric arrangements of seeds containing 125 I, Amersham Health model of type 6711 in prostates of different sizes, in order to try to quantify some of the parameters. The computational model was validated using a phantom prostate cubic RW3 type , consisting of tissue equivalent, and thermoluminescent dosimeters. Finally, to have a term of comparison with a treatment real plan it was simulate a treatment plan used in a hospital of Rio de Janeiro, with exactly the same parameters, and our computational model. The results obtained in our study seem to indicate that the parameters described above may be a source of uncertainty in the correct evaluation of the dose required for actual treatment plans. The use of Monte Carlo techniques can serve as a complementary

  4. American Brachytherapy Society Task Group Report: Combination of brachytherapy and external beam radiation for high-risk prostate cancer.

    Science.gov (United States)

    Spratt, Daniel E; Soni, Payal D; McLaughlin, Patrick W; Merrick, Gregory S; Stock, Richard G; Blasko, John C; Zelefsky, Michael J

    To review outcomes for high-risk prostate cancer treated with combined modality radiation therapy (CMRT) utilizing external beam radiation therapy (EBRT) with a brachytherapy boost. The available literature for high-risk prostate cancer treated with combined modality radiation therapy was reviewed and summarized. At this time, the literature suggests that the majority of high-risk cancers are curable with multimodal treatment. Several large retrospective studies and three prospective randomized trials comparing CMRT to dose-escalated EBRT have demonstrated superior biochemical control with CMRT. Longer followup of the randomized trials will be required to determine if this will translate to a benefit in metastasis-free survival, disease-specific survival, and overall survival. Although greater toxicity has been associated with CMRT compared to EBRT, recent studies suggest that technological advances that allow better definition and sparing of critical adjacent structures as well as increasing experience with brachytherapy have improved implant quality and the toxicity profile of brachytherapy. The role of androgen deprivation therapy is well established in the external beam literature for high-risk disease, but there is controversy regarding the applicability of these data in the setting of dose escalation. At this time, there is not sufficient evidence for the omission of androgen deprivation therapy with dose escalation in this population. Comparisons with surgery remain limited by differences in patient selection, but the evidence would suggest better disease control with CMRT compared to surgery alone. Due to a series of technological advances, modern combination series have demonstrated unparalleled rates of disease control in the high-risk population. Given the evidence from recent randomized trials, combination therapy may become the standard of care for high-risk cancers. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All

  5. Salvage high-dose-rate brachytherapy for local prostate cancer recurrence after radical radiotherapy

    Directory of Open Access Journals (Sweden)

    V. A. Solodkiy

    2016-01-01

    Full Text Available Studies salvage interstitial radiation therapy for recurrent prostate cancer, launched at the end of the XX century. In recent years, more and more attention is paid to high-dose-rate brachytherapy (HDR-BT as a method of treating local recurrence.The purpose of research – preliminary clinical results of salvage high-dose-rate brachytherapy applied in cases of suspected local recurrence or of residual tumour after radiotherapy.Preliminary findings indicate the possibility of using HDR-BT, achieving local tumor control with low genitourinary toxicity.

  6. SU-F-I-19: MRI Positive Contrast Visualization of Prostate Brachytherapy Seeds Using An Integrated Laplacian-Based Phase Processing

    Energy Technology Data Exchange (ETDEWEB)

    Soliman, A; Safigholi, H [Sunnybrook Research Institute, Toronto, ON (Canada); Sunnybrook Health Sciences Center, Toronto, ON (Canada); Nosrati, R [Sunnybrook Health Sciences Center, Toronto, ON (Canada); Ryerson University, Toronto, ON (Canada); Owrangi, A; Morton, G [Sunnybrook Health Sciences Center, Toronto, ON (Canada); University of Toronto, Toronto, ON (Canada); Song, W [Sunnybrook Research Institute, Toronto, ON (Canada); Sunnybrook Health Sciences Center, Toronto, ON (Canada); Ryerson University, Toronto, ON (Canada); University of Toronto, Toronto, ON (Canada)

    2016-06-15

    Purpose: To propose a new method that provides a positive contrast visualization of the prostate brachytherapy seeds using the phase information from MR images. Additionally, the feasibility of using the processed phase information to distinguish seeds from calcifications is explored. Methods: A gel phantom was constructed using 2% agar dissolved in 1 L of distilled water. Contrast agents were added to adjust the relaxation times. Four iodine-125 (Eckert & Ziegler SML86999) dummy seeds were placed at different orientations with respect to the main magnetic field (B0). Calcifications were obtained from a sheep femur cortical bone due to its close similarity to human bone tissue composition. Five samples of calcifications were shaped into different dimensions with lengths ranging between 1.2 – 6.1 mm.MR imaging was performed on a 3T Philips Achieva using an 8-channel head coil. Eight images were acquired at eight echo-times using a multi-gradient echo sequence. Spatial resolution was 0.7 × 0.7 × 2 mm, TR/TE/dTE = 20.0/2.3/2.3 ms and BW = 541 Hz/pixel. Complex images were acquired and fed into a two-step processing pipeline: the first includes phase unwrapping and background phase removal using Laplacian operator (Wei et al. 2013). The second step applies a specific phase mask on the resulting tissue phase from the first step to provide the desired positive contrast of the seeds and to, potentially, differentiate them from the calcifications. Results: The phase-processing was performed in less than 30 seconds. The proposed method has successfully resulted in a positive contrast of the brachytherapy seeds. Additionally, the final processed phase image showed difference between the appearance of seeds and calcifications. However, the shape of the seeds was slightly distorted compared to the original dimensions. Conclusion: It is feasible to provide a positive contrast of the seeds from MR images using Laplacian operator-based phase processing.

  7. Comparison of MRI-based and CT/MRI fusion-based postimplant dosimetric analysis of prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Sakurai, Kota; Nakano, Masahiro; Maeda, Sunaho; Kajita, Kimihiro R.T.; Deguchi, Takashi; Hoshi, Hiroaki

    2006-01-01

    Purpose: The aim of this study was to compare the outcomes between magnetic resonance imaging (MRI)-based and computed tomography (CT)/MRI fusion-based postimplant dosimetry methods in permanent prostate brachytherapy. Methods and Materials: Between October 2004 and March 2006, a total of 52 consecutive patients with prostate cancer were treated by brachytherapy, and postimplant dosimetry was performed using CT/MRI fusion. The accuracy and reproducibility were prospectively compared between MRI-based dosimetry and CT/MRI fusion-based dosimetry based on the dose-volume histogram (DVH) related parameters as recommended by the American Brachytherapy Society. Results: The prostate volume was 15.97 ± 6.17 cc (mean ± SD) in MRI-based dosimetry, and 15.97 ± 6.02 cc in CT/MRI fusion-based dosimetry without statistical difference. The prostate V100 was 94.5% and 93.0% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.002). The prostate D90 was 119.4% and 114.4% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.004). Conclusion: Our current results suggested that, as with fusion images, MR images allowed accurate contouring of the organs, but they tended to overestimate the analysis of postimplant dosimetry in comparison to CT/MRI fusion images. Although this MRI-based dosimetric discrepancy was negligible, MRI-based dosimetry was acceptable and reproducible in comparison to CT-based dosimetry, because the difference between MRI-based and CT/MRI fusion-based results was smaller than that between CT-based and CT/MRI fusion-based results as previously reported

  8. Biomaterial characteristics and application of silicone rubber and PVA hydrogels mimicked in organ groups for prostate brachytherapy.

    Science.gov (United States)

    Li, Pan; Jiang, Shan; Yu, Yan; Yang, Jun; Yang, Zhiyong

    2015-09-01

    It is definite that transparent material with similar structural characteristics and mechanical properties to human tissue is favorable for experimental study of prostate brachytherapy. In this paper, a kind of transparent polyvinyl alcohol (PVA) hydrogel and silicone rubber are developed as suitable substitutions for human soft tissue. Segmentation and 3D reconstruction of medical image are performed to manufacture the mould of organ groups through rapid prototyping technology. Micro-structure observation, force test and CCD deformation test have been conducted to investigate the structure and mechanical properties of PVA hydrogel used in organ group mockup. Scanning electron microscope (SEM) image comparison results show that PVA hydrogel consisting of 3 g PVA, 17 g de-ionized water, 80 g dimethyl-sulfoxide (DMSO), 4 g NaCl, 1.5 g NaOH, 3 g epichlorohydrin (ECH) and 7 freeze/thaw cycles reveals similar micro-structure to human prostate tissue. Through the insertion force comparison between organ group mockup and clinical prostate brachytherapy, PVA hydrogel and silicone rubber are found to have the same mechanical properties as prostate tissue and muscle. CCD deformation test results show that insertion force suffers a sharp decrease and a relaxation of tissue deformation appears when needle punctures the capsule of prostate model. The results exhibit that organ group mockup consisting of PVA hydrogel, silicone rubber, membrane and agarose satisfies the needs of prostate brachytherapy simulation in general and can be used to mimic the soft tissues in pelvic structure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Seed displacements after permanent brachytherapy for prostate cancer in dependence on the prostate level

    International Nuclear Information System (INIS)

    Pinkawa, M.; Gagel, B.; Asadpour, B.; Piroth, M.D.; Klotz, J.; Eble, M.J.; Borchers, H.; Jakse, G.

    2008-01-01

    Purpose: to evaluate seed displacements after permanent prostate brachytherapy considering different prostate levels. Patients and methods: in 61 patients, postimplant CT scans were performed 1 day and 1 month after an implant with stranded seeds. Seed and prostate surface displacements were determined relative to pelvic bones. Four groups of seed locations were selected: seeds at the base (n = 305; B), at the apex (n = 305; A), close to the urethra (n = 306; U), and close to the rectal wall (n = 204; R). The length of two strands (always containing four seeds) per patient was measured in all CT scans and compared. Results: the largest inferior seed displacements were found at the base: mean 5.3 mm (B), 2.2 mm (A), 2.7 mm (U), 3.3 mm (R; p 3 vs. 41 cm 3 ; p < 0.001), a mean caudal prostate base displacement of 3.9 mm was found, whereas the mean inward displacement ranged from 1.2 to 1.6 mm at the remaining borders (lateral, anterior, posterior, apical). The analysis of the strand lengths revealed an implant compression between day 1 and 30 (mean 1.7 mm; p < 0.001). Conclusion: the largest prostate tissue and seed displacements were observed at the prostate base, associated with an implant compression. Predominantly inferior and posterior displacements implicate consequential smaller preplanning margins at the apex and the posterior prostate. (orig.)

  10. The Impact of Brachytherapy on Prostate Cancer–Specific Mortality for Definitive Radiation Therapy of High-Grade Prostate Cancer: A Population-Based Analysis

    International Nuclear Information System (INIS)

    Shen Xinglei; Keith, Scott W.; Mishra, Mark V.; Dicker, Adam P.; Showalter, Timothy N.

    2012-01-01

    Purpose: This population-based analysis compared prostate cancer–specific mortality (PCSM) in a cohort of patients with high-risk prostate cancer after nonsurgical treatment with external beam radiation therapy (EBRT), brachytherapy (BT), or combination (BT + EBRT). Methods and Materials: We identified from the Surveillance, Epidemiology and End Results database patients diagnosed from 1988 through 2002 with T1–T3N0M0 prostate adenocarcinoma of poorly differentiated grade and treated with BT, EBRT, or BT + EBRT. During this time frame, the database defined high grade as prostate cancers with Gleason score 8–10, or Gleason grade 4–5 if the score was not recorded. This corresponds to a cohort primarily with high-risk prostate cancer, although some cases where only Gleason grade was recorded may have included intermediate-risk cancer. We used multivariate models to examine patient and tumor characteristics associated with the likelihood of treatment with each radiation modality and the effect of radiation modality on PCSM. Results: There were 12,745 patients treated with EBRT (73.5%), BT (7.1%), or BT + EBRT (19.4%) included in the analysis. The median follow-up time for all patients was 6.4 years. The use of BT or BT + EBRT increased from 5.1% in 1988–1992 to 31.4% in 1998–2002. Significant predictors of use of BT or BT + EBRT were younger age, later year of diagnosis, urban residence, and earlier T-stage. On multivariate analysis, treatment with either BT (hazard ratio, 0.66; 95% confidence interval, 0.49–0.86) or BT + EBRT (hazard ratio, 0.77; 95% confidence ratio, 0.66–0.90) was associated with significant reduction in PCSM compared with EBRT alone. Conclusion: In patients with high-grade prostate cancer, treatment with brachytherapy is associated with reduced PCSM compared with EBRT alone. Our results suggest that brachytherapy should be investigated as a component of definitive treatment strategies for patients with high-risk prostate cancer.

  11. Three-dimensional (3D) real-time conformal brachytherapy - a novel solution for prostate cancer treatment Part I. Rationale and method

    International Nuclear Information System (INIS)

    Fijalkowski, M.; Bialas, B.; Maciejewski, B.; Bystrzycka, J.; Slosarek, K.

    2005-01-01

    Recently, the system for conformal real-time high-dose-rate brachytherapy has been developed and dedicated in general for the treatment of prostate cancer. The aim of this paper is to present the 3D-conformal real-time brachytherapy technique introduced to clinical practice at the Institute of Oncology in Gliwice. Equipment and technique of 3D-conformal real time brachytherapy (3D-CBRT) is presented in detail and compared with conventional high-dose-rate brachytherapy. Step-by-step procedures of treatment planning are described, including own modifications. The 3D-CBRT offers the following advantages: (1) on-line continuous visualization of the prostate and acquisition of the series of NS images during the entire procedure of planning and treatment; (2) high precision of definition and contouring the target volume and the healthy organs at risk (urethra, rectum, bladder) based on 3D transrectal continuous ultrasound images; (3) interactive on-line dose optimization with real-time corrections of the dose-volume histograms (DVHs) till optimal dose distribution is achieved; (4) possibility to overcome internal prostate motion and set-up inaccuracies by stable positioning of the prostate with needles fixed to the template; (5) significant shortening of overall treatment time; (6) cost reduction - the treatment can be provided as an outpatient procedure. The 3D- real time CBRT can be advertised as an ideal conformal boost dose technique integrated or interdigitated with pelvic conformal external beam radiotherapy or as a monotherapy for prostate cancer. (author)

  12. Production of 125I from amorphous films of Si doped with 124Xe and evaluation of its potential use in brachytherapy

    International Nuclear Information System (INIS)

    Leal, Alexandre S.; Viana, Gustavo A.

    2015-01-01

    This work describes the simulation of a new material that can be used in the brachytherapy treatment. The material consists of xenon-incorporated amorphous silicon (Xe@a-Si). The irradiated 124 Xe atoms of the samples are converted into 125 Xe, according to the reaction: 124 Xe (n,γ) 125 Xe that, in turn, decays to the radioisotope 125 I. A set of simulations performed using the MCNP5 code, shows that, in principle, the material proposed can be used in the seed of brachytherapy in the clinical treatment. (author)

  13. Epoxy resins used to seal brachytherapy seed

    International Nuclear Information System (INIS)

    Ferreira, Natalia Carolina Camargos; Ferraz, Wilmar Barbosa; Reis, Sergio Carneiro dos; Santos, Ana Maria Matildes dos

    2013-01-01

    Prostate cancer treatment with brachytherapy is recommended for patients with cancer at an early stage. In this treatment, small radioactive seeds are implanted directly in the prostate gland. These seeds are composed at least of one radionuclide carrier and an X-ray marker enclosed within a metallic tube usually sealed by laser process. This process is expensive and, furthermore, it can provoke a partial volatilization of the radionuclide and change the isotropy in dose distribution around the seed. In this paper, we present a new sealing process using epoxy resin. Three kinds of resins were utilized and characterized by scanning electron microscopy (SEM), energy dispersive X ray (EDS) and by differential scanning calorimetry (DSC) after immersion in simulated body fluid (SBF) and in sodium iodine solution (NaI). The sealing process showed excellent potential to replace the sealing laser usually employed. (author)

  14. MRI-based preplanning in low-dose-rate prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Nakano, Masahiro; Kubota, Yasuaki; Maeda, Sunaho; Ohtakara, Kazuhiro; Deguchi, Takashi; Hoshi, Hiroaki

    2008-01-01

    Purpose: To compare the dosimetric results between MRI-based and TRUS-based preplanning in permanent prostate brachytherapy, and to estimate the accuracy of MRI-based preplanning by comparing with CT/MRI fusion-based postimplant dosimetry. Methods and materials: Twenty-one patients were entered in this prospective study with written informed consent. MRI-based and TRUS-based preplanning were performed. The seed and needle locations were identical according to MRI-based and TRUS-based preplanning. MRI-based and TRUS-based preplanning were compared using DVH-related parameters. Following brachytherapy, the accuracy of the MRI-based preplanning was evaluated by comparing it with CT/MRI fusion-based postimplant dosimetry. Results: Mean MRI-based prostate volume was slightly underestimated (0.73 cc in mean volume) in comparison to TRUS-based volume. There were no significant differences in the mean DVH-related parameters except with rectal V 100 (cc) between TRUS-based and MRI-based preplanning. Mean rectal V 100 (cc) was 0.74 cc in TRUS-based and 0.29 cc in MRI-based preplanning, respectively, and the values demonstrated a statistical difference. There was no statistical difference in mean rectal V 150 (cc), and rectal V 100 (cc) between MRI-based preplanning and CT/MRI fusion-based postimplant dosimetry. Conclusion: Prostate volume estimation and DVH-related parameters in MRI-based preplanning were almost identical to TRUS-based preplanning. From the results of CT/MRI fusion-based postimplant dosimetry, MRI-based preplanning was therefore found to be a reliable and useful modality, as well as being helpful for TRUS-based preplanning. MRI-based preplanning can more accurately predict postimplant rectal dose than TRUS-based preplanning

  15. Local anesthesia for prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Simpson, Colleen; Roof, James; Arthurs, Sandy; Korssjoen, Tammy; Sutlief, Steven

    1999-01-01

    Purpose: To demonstrate the technique and feasibility of prostate brachytherapy performed with local anesthesia only. Methods and Materials: A 5 by 5 cm patch of perineal skin and subcutaneous tissue is anesthetized by local infiltration of 10 cc of 1% lidocaine with epinephrine, using a 25-gauge 5/8-inch needle. Immediately following injection into the subcutaneous tissues, the deeper tissues, including the pelvic floor and prostate apex, are anesthetized by injecting 15 cc lidocaine solution with approximately 8 passes of a 20-gauge 1.0-inch needle. Following subcutaneous and peri-apical lidocaine injections, the patient is brought to the simulator suite and placed in leg stirrups. The transrectal ultrasound (TRUS) probe is positioned to reproduce the planning images and a 3.5- or 6.0-inch, 22-gauge spinal needle is inserted into the peripheral planned needle tracks, monitored by TRUS. When the tips of the needles reach the prostatic base, about 1 cc of lidocaine solution is injected in the intraprostatic track, as the needle is slowly withdrawn, for a total volume of 15 cc. The implants are done with a Mick Applicator, inserting and loading groups of two to four needles, so that a maximum of only about four needles are in the patient at any one time. During the implant procedure, an additional 1 cc of lidocaine solution is injected into one or more needle tracks if the patient experiences substantial discomfort. The total dose of lidocaine is generally limited to 500 mg (50 ml of 1% solution). Results: To date, we have implanted approximately 50 patients in our simulator suite, using local anesthesia. Patients' heart rate and diastolic blood pressure usually showed moderate changes, consistent with some discomfort. The time from first subcutaneous injection and completion of the source insertion ranged from 35 to 90 minutes. Serum lidocaine levels were below or at the low range of therapeutic. There has been only one instance of acute urinary retention in the

  16. Long term conservation of sexual functions after prostate brachytherapy by permanents implants

    International Nuclear Information System (INIS)

    Pena, P.C.; Hijal, T.; Pierrat, N.; Pontvert, D.; Cosset, J.M.; Thiounn, N.; Flam, T.; Chauveinc, L.

    2009-01-01

    These series suggest that the preservation of sexual abilities after prostate brachytherapy would be in relation with the previous performances and age. So, in patients aged over seventy years and with an satisfying initial IIEF5 score, the conservation rate at long term appears to go over the 50%. (N.C.)

  17. Seed loss through the urinary tract after prostate brachytherapy: examining the role of cystoscopy and urine straining post implant

    International Nuclear Information System (INIS)

    Stutz, Michael; Petrikas, James; Raslowsky, Michael; Lee, Plato; Gurel, Michelle; Moran, Brian

    2003-01-01

    This study describes one institution's experience with seed retrieval through the urinary tract and makes recommendations for cystoscopy and urine straining post prostate brachytherapy (PB). 1794 patients from two separate cohorts covering different time periods (early versus late) were analyzed. All patients were preplanned with a modified peripheral loading technique and implanted with preloaded needles ( 125 I or 103 Pd) under ultrasound guidance. A catheter was used to delineate the urethra during the volume study but was not used during the implant. All patients underwent post implant cystoscopy. All patients were instructed to strain their urine for seven days post implant and return any seeds to our center. In our experience, seed loss through the urinary tract is a common event after PB, occurring in 29.7% of patients and was more common in patients from the early cohort, those implanted with 125 I seeds or those patients with prior transurethral resection of the prostate. Average seed loss per case, however, represents only 0.58% of total activity. We continue to recommend routine post implant cystoscopy for seed retrieval and periprocedural management. We no longer recommend that patients strain their urine at home after documenting a low rate of seed loss after discharge

  18. Rectal fistulas after prostate brachytherapy

    International Nuclear Information System (INIS)

    Tran, Audrey; Wallner, Kent; Merrick, Gregory; Seeberger, Jergen M.S.; Armstrong, Julius R.T.T.; Mueller, Amy; Cavanagh, William M.S.; Lin, Daniel; Butler, Wayne

    2005-01-01

    Purpose: To compare the rectal and prostatic radiation doses for a prospective series of 503 patients, 44 of whom developed persistent rectal bleeding, and 2 of whom developed rectal-prostatic fistulas. Methods and Materials: The 503 patients were randomized and treated by implantation with 125 I vs. 103 Pd alone (n = 290) or to 103 Pd with 20 Gy vs. 44 Gy supplemental external beam radiotherapy (n = 213) and treated at the Puget Sound Veterans Affairs Medical Center (n = 227), Schiffler Cancer Center (n 242) or University of Washington (n = 34). Patients were treated between September 1998 and October 2001 and had a minimum of 24 months of follow-up. The patient groups were treated concurrently. Treatment-related morbidity was monitored by mailed questionnaires, using standard American Urological Association and Radiation Therapy Oncology Group criteria, at 1, 3, 6, 12, 18, and 24 months. Patients who reported Grade 1 or greater Radiation Therapy Oncology Group rectal morbidity were interviewed by telephone to clarify details regarding their rectal bleeding. Those who reported persistent bleeding, lasting for >1 month were included as having Grade 2 toxicity. Three of the patients with rectal bleeding required a colostomy, two of whom developed a fistula. No patient was lost to follow-up. The rectal doses were defined as the rectal volume in cubic centimeters that received >50%, 100%, 200%, or 300% of the prescription dose. The rectum was considered as a solid structure defined by the outer wall, without attempting to differentiate the inner wall or contents. Results: Persistent rectal bleeding occurred in 44 of the 502 patients, 32 of whom (73%) underwent confirmatory endoscopy. In univariate analysis, multiple parameters were associated with late rectal bleeding, including all rectal brachytherapy indexes. In multivariate analysis, however, only the rectal volume that received >100% of the dose was significantly predictive of bleeding. Rectal fistulas occurred

  19. DNA Ploidy Measured on Archived Pretreatment Biopsy Material May Correlate With Prostate-Specific Antigen Recurrence After Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Keyes, Mira, E-mail: mkeyes@bccancer.bc.ca [Radiation Oncology, Provincial Prostate Brachytherapy Program, Vancouver Cancer Centre, British Columbia Cancer Agency, Vancouver, British Columbia (Canada); MacAulay, Calum [Department of Integrative Oncology, British Columbia Cancer Research Centre, British Columbia Cancer Agency, Vancouver, British Columbia (Canada); Hayes, Malcolm [Department of Pathology, Vancouver Cancer Centre, British Columbia Cancer Agency, Vancouver, British Columbia (Canada); Korbelik, Jagoda [Department of Integrative Oncology, British Columbia Cancer Research Centre, British Columbia Cancer Agency, Vancouver, British Columbia (Canada); Morris, W. James [Radiation Oncology, Provincial Prostate Brachytherapy Program, Vancouver Cancer Centre, British Columbia Cancer Agency, Vancouver, British Columbia (Canada); Palcic, Branko [Department of Integrative Oncology, British Columbia Cancer Research Centre, British Columbia Cancer Agency, Vancouver, British Columbia (Canada)

    2013-08-01

    Purpose: To explore whether DNA ploidy of prostate cancer cells determined from archived transrectal ultrasound-guided biopsy specimens correlates with disease-free survival. Methods and Materials: Forty-seven failures and 47 controls were selected from 1006 consecutive low- and intermediate-risk patients treated with prostate {sup 125}I brachytherapy (July 1998-October 2003). Median follow-up was 7.5 years. Ten-year actuarial disease-free survival was 94.1%. Controls were matched using age, initial prostate-specific antigen level, clinical stage, Gleason score, use of hormone therapy, and follow-up (all P nonsignificant). Seventy-eight specimens were successfully processed; 27 control and 20 failure specimens contained more than 100 tumor cells were used for the final analysis. The Feulgen-Thionin stained cytology samples from archived paraffin blocks were used to determine the DNA ploidy of each tumor by measuring integrated optical densities. Results: The samples were divided into diploid and aneuploid tumors. Aneuploid tumors were found in 16 of 20 of the failures (80%) and 8 of 27 controls (30%). Diploid DNA patients had a significantly lower rate of disease recurrence (P=.0086) (hazard ratio [HR] 0.256). On multivariable analysis, patients with aneuploid tumors had a higher prostate-specific antigen failure rate (HR 5.13). Additionally, those with “excellent” dosimetry (V100 >90%; D90 >144 Gy) had a significantly lower recurrence rate (HR 0.25). All patients with aneuploid tumors and dosimetry classified as “nonexcellent” (V100 <90%; D90 <144 Gy) (5 of 5) had disease recurrence, compared with 40% of patients with aneuploid tumors and “excellent” dosimetry (8 of 15). In contrast, dosimetry did not affect the outcome for diploid patients. Conclusions: Using core biopsy material from archived paraffin blocks, DNA ploidy correctly classified the majority of failures and nonfailures in this study. The results suggest that DNA ploidy can be used as a

  20. The case for focal brachytherapy for the management of low grade prostate cancer

    International Nuclear Information System (INIS)

    Allen, B.J.; Enari, E.

    2011-01-01

    Full text: Radical therapy of low to intermediate prostate cancer patients can cause substantial adverse events relating to genitourinary and rectal toxicity. Yet there is little evidence that such treatment results in increased life expectancy. On the other hand, watchful waiting is associated with active surveillance and the patient must accept that the cancer remains untreated and has a risk of progression. Focal therapy of low grade prostate cancer provides an intermediate approach to the management of this cancer. The approach is to treat only those positive segments on biopsy and so reduce the likelihood of adverse events. However, continued surveillance is required because of the increased risk of disease progression. Focal therapy needs to be evaluated using available ablative therapies. Recent studies of focal HIFU for 20 patients showed PSA reduced from 7.3 to 1.5 ng/mL at 12 months. 1/20 patients had inadequate erections and 2120 required pads. 17/19 had no histological evidence of cancer and none had evidence of high volume or Gleason = 7 cancer in the treated lobe. Seed brachytherapy is commonly used for radical prostate treatment of low volume disease. As the same template can be used for seed therapy as is used for biopsy, the technique is ideally suited for focal brachytherapy. As any treatment involving less than the entire gland involves the risk of leaving viable cancer cells outside the treatment zone, a phase 3 randomised clinical trial between radical and focal brachytherapy is advocated to demonstrate the efficacy and safety of the latter relative to radical therapy.

  1. Urethral stricture following high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Sullivan, Lisa; Williams, Scott G.; Tai, Keen Hun; Foroudi, Farshad; Cleeve, L.; Duchesne, Gillian M.

    2009-01-01

    Purpose: To evaluate the incidence, timing, nature and outcome of urethral strictures following high dose rate brachytherapy (HDRB) for prostate carcinoma. Methods and materials: Data from 474 patients with clinically localised prostate cancer treated with HDRB were analysed. Ninety percent received HDRB as a boost to external beam radiotherapy (HDRBB) and the remainder as monotherapy (HDRBM). Urethral strictures were graded according to the Common Terminology Criteria for Adverse Events v3.0. Results: At a median follow-up of 41 months, 38 patients (8%) were diagnosed with a urethral stricture (6-year actuarial risk 12%). Stricture location was bulbo-membranous (BM) urethra in 92.1%. The overall actuarial rate of grade 2 or more BM urethral stricture was estimated at 10.8% (95% CI 7.0-14.9%), with a median time to diagnosis of 22 months (range 10-68 months). All strictures were initially managed with either dilatation (n = 15) or optical urethrotomy (n = 20). Second line therapy was required in 17 cases (49%), third line in three cases (9%) and 1 patient open urethroplasty (grade 3 toxicity). Predictive factors on multivariate analysis were prior trans-urethral resection of prostate (hazard ratio (HR) 2.81, 95% CI 1.15-6.85, p = 0.023); hypertension (HR 2.83, 95% CI 1.37-5.85, p = 0.005); and dose per fraction used in HDR (HR for 1 Gy increase per fraction 1.33, 95% CI 1.08-1.64, p = 0.008). Conclusions: BM urethral strictures are the most common late grade 2 or more urinary toxicity following HDR brachytherapy for prostate cancer. Most are manageable with minimally invasive procedures. Both clinical and dosimetric factors appear to influence the risk of stricture formation.

  2. Interactive, multi-modality image registrations for combined MRI/MRSI-planned HDR prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Galen Reed

    2011-03-01

    Full Text Available Purpose: This study presents the steps and criteria involved in the series of image registrations used clinically during the planning and dose delivery of focal high dose-rate (HDR brachytherapy of the prostate. Material and methods: Three imaging modalities – Magnetic Resonance Imaging (MRI, Magnetic Resonance Spectroscopic Imaging (MRSI, and Computed Tomography (CT – were used at different steps during the process. MRSI is used for identification of dominant intraprosatic lesions (DIL. A series of rigid and nonrigid transformations were applied to the data to correct for endorectal-coil-induced deformations and for alignment with the planning CT. Mutual information was calculated as a morphing metric. An inverse planning optimization algorithm was applied to boost dose to the DIL while providing protection to the urethra, penile bulb, rectum, and bladder. Six prostate cancer patients were treated using this protocol. Results: The morphing algorithm successfully modeled the probe-induced prostatic distortion. Mutual information calculated between the morphed images and images acquired without the endorectal probe showed a significant (p = 0.0071 increase to that calculated between the unmorphed images and images acquired without the endorectal probe. Both mutual information and visual inspection serve as effective diagnostics of image morphing. The entire procedure adds less than thirty minutes to the treatment planning. Conclusion: This work demonstrates the utility of image transformations and registrations to HDR brachytherapy of prostate cancer.

  3. Dosimetric comparison of interactive planned and dynamic dose calculated prostate seed brachytherapy.

    Science.gov (United States)

    Meijer, Gert J; van den Berg, Hetty A; Hurkmans, Coen W; Stijns, Pascal E; Weterings, Jan H

    2006-09-01

    To compare the dosimetrical results of an interactive planning procedure and a procedure based on dynamic dose calculation for permanent prostate brachytherapy. Between 6/2000 and 11/2005, 510 patients underwent (125)I implants for T1-T2 prostate cancer. Before 4/2003, 187 patients were treated using an interactive technique that included needle updating. After that period, 323 patients were treated with a more refined dynamic technique that included constant updating of the deposited seed position. The comparison is based on postimplant dose - volume parameters such as the V(100) and d(90) for the target, V(100)(r) for the rectum and d(10)(u) for the urethra. Furthermore, the target volume ratios (TVR identical with V(100)(body)/V(100)), and the homogeneity indices (HI identical with [V(100)-V(150)]/V(100)) were calculated as additional quality parameters. The dose outside the target volume was significantly reduced, the V(100)(r) decreased from 1.4 cm(3) for the interactive technique to 0.6 cm(3) for the dynamic technique. Similarly the mean TVR reduced from 1.66 to 1.44. In addition, the mean V(100) increased from 92% for the interactive procedure to 95% for the dynamic procedure. More importantly, the percentage of patients with a V(100) < 80% reduced from 5% to 1%. A slight decline was observed with regard to the d(10)(u) (136% vs. 140%) and the HI (0.58 vs. 0.51). The dynamic implant procedure resulted in improved implants. Almost ideal dose coverage was achieved, while minimizing the dose outside the prostate.

  4. A Dose–Response Analysis of Biochemical Control Outcomes After {sup 125}I Monotherapy for Patients With Favorable-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Shiraishi, Yutaka, E-mail: shiraishi@rad.med.keio.ac.jp [Department of Radiology, Keio University School of Medicine, Tokyo (Japan); Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Yorozu, Atsunori [Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Ohashi, Toshio [Department of Radiology, Keio University School of Medicine, Tokyo (Japan); Toya, Kazuhito [Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Saito, Shiro; Nishiyama, Toru; Yagi, Yasuto [Department of Urology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Shigematsu, Naoyuki [Department of Radiology, Keio University School of Medicine, Tokyo (Japan)

    2014-12-01

    Purpose: To define the optimal dose for {sup 125}I prostate implants by correlating postimplantation dosimetry findings with biochemical failure and toxicity. Methods and Materials: Between 2003 and 2009, 683 patients with prostate cancer were treated with {sup 125}I prostate brachytherapy without supplemental external beam radiation therapy and were followed up for a median time of 80 months. Implant dose was defined as the D90 (the minimal dose received by 90% of the prostate) on postoperative day 1 and 1 month after implantation. Therefore, 2 dosimetric variables (day 1 D90 and day 30 D90) were analyzed for each patient. We investigated the dose effects on biochemical control and toxicity. Results: The 7-year biochemical failure-free survival (BFFS) rate for the group overall was 96.4% according to the Phoenix definition. A multivariate analysis found day 1 D90 and day 30 D90 to be the most significant factors affecting BFFS. The cutoff points for day 1 D90 and day 30 D90, calculated from ROC curves, were 163 Gy and 175 Gy, respectively. By use of univariate analysis, various dosimetric cutoff points for day 30 D90 were tested. We found that day 30 D90 cutoff points from 130 to 180 Gy appeared to be good for the entire cohort. Greater D90s were associated with an increase in late genitourinary or gastrointestinal toxicity ≥ grade 2, but the increase was not statistically significant. Conclusions: Improvements in BFFS rates were seen with increasing D90 levels. Day 30 D90 doses of 130 to 180 Gy were found to serve as cutoff levels. For low-risk and low-tier intermediate-risk prostate cancer patients, high prostate D90s, even with doses exceeding 180 Gy, achieve better treatment results and are feasible.

  5. LOW POWER BRACHYTHERAPY IN COMBINED TREATMENT IN PATIENTS WITH INTERMEDIATE RISK OF LOCALIZED PROST ATE CANCER

    Directory of Open Access Journals (Sweden)

    V. A. Biryukov

    2014-01-01

    Full Text Available Objective. Estimation of the effectiveness of low power brachytherapy sources I-125 in the combined treatment in group of patients of intermediate risk of localized prostate cancer.Material and methods. The study included 126 patients with prostate cancer of intermediate risk. 104 patients (83,9% were conducted low power brachytherapy I‑125 in combination with hormone therapy by analogues of LHWG. 22 patients (16.1% received external beam irradiation in combination with brachytherapy I‑125 and hormonal treatment. Relapse-free survival of patients was evaluated in accordance with the criteria Phoenix (Nadir PSA + ng/ml. Evaluation of side effects of radiation treatment were carried out according to the RTOG criteria.Results. PSA relapse-free survival in the group of brachytherapy and hormone treatment at the time of observation 5 years amounted to 97.1%. In the group of combined radiation therapy with brachytherapy, and hormonal treatment PSA relapse-free survival rate was 95.5%.In both groups, relapse-free survival was noted in 96,8% of cases. Tumor-specific and overall survival in bothgroups was 100%. The major complications of treatment in both groups were radiation urethritis 1 to 2 degrees in 9.5% of cases (12 patients, urethral stricture in 5 patients (3.9% of cases, acute urinary retention in 1 patient (0.8% of cases and late radiation rectitis of 2 degree in 1.58% of cases (2 patients.Conclusions. It is possible to draw tentative conclusions about the high rate of survival without progression in both treatment groups on the background of the relatively low frequency of adverse reactions. It is necessary further follow-up for patients with estimating of survival for a longer period.

  6. Race and Survival Following Brachytherapy-Based Treatment for Men With Localized or Locally Advanced Adenocarcinoma of the Prostate

    International Nuclear Information System (INIS)

    Winkfield, Karen M.; Chen Minghui; Dosoretz, Daniel E.; Salenius, Sharon A.; Katin, Michael; Ross, Rudi; D’Amico, Anthony V.

    2011-01-01

    Purpose: We investigated whether race was associated with risk of death following brachytherapy-based treatment for localized prostate cancer, adjusting for age, cardiovascular comorbidity, treatment, and established prostate cancer prognostic factors. Methods: The study cohort was composed of 5,360 men with clinical stage T1-3N0M0 prostate cancer who underwent brachytherapy-based treatment at 20 centers within the 21st Century Oncology consortium. Cox regression multivariable analysis was used to evaluate the risk of death in African-American and Hispanic men compared to that in Caucasian men, adjusting for age, pretreatment prostate-specific antigen (PSA) level, Gleason score, clinical T stage, year and type of treatment, median income, and cardiovascular comorbidities. Results: After a median follow-up of 3 years, there were 673 deaths. African-American and Hispanic races were significantly associated with an increased risk of all-cause mortality (ACM) (adjusted hazard ratio, 1.77 and 1.79; 95% confidence intervals, 1.3–2.5 and 1.2–2.7; p < 0.001 and p = 0.005, respectively). Other factors significantly associated with an increased risk of death included age (p < 0.001), Gleason score of 8 to 10 (p = 0.04), year of brachytherapy (p < 0.001), and history of myocardial infarction treated with stent or coronary artery bypass graft (p < 0.001). Conclusions: After adjustment for prostate cancer prognostic factors, age, income level, and revascularized cardiovascular comorbidities, African-American and Hispanic races were associated with higher ACM in men with prostate cancer. Additional causative factors need to be identified.

  7. Salvage prostate HDR brachytherapy combined with interstitial hyperthermia for local recurrence after radiation therapy failure

    Energy Technology Data Exchange (ETDEWEB)

    Kukielka, A.M.; Hetnal, M.; Dabrowski, T.; Walasek, T.; Brandys, P.; Reinfuss, M. [Centre of Oncology, M. Sklodowska - Curie Institute, Krakow Branch, Department of Radiotherapy, Krakow (Poland); Nahajowski, D.; Kudzia, R.; Dybek, D. [Centre of Oncology, M. Sklodowska - Curie Institute, Krakow Branch, Department of Medical Physics, Department of Radiotherapy, Krakow (Poland)

    2014-02-15

    The aim of the present retrospective study is to evaluate toxicity and early clinical outcomes of interstitial hyperthermia (IHT) combined with high-dose rate (HDR) brachytherapy as a salvage treatment in patients with biopsy-confirmed local recurrence of prostate cancer after previous external beam radiotherapy. Between September 2008 and March 2013, 25 patients with local recurrence of previously irradiated prostate cancer were treated. The main eligibility criteria for salvage prostate HDR brachytherapy combined with interstitial hyperthermia were biopsy confirmed local recurrence and absence of nodal and distant metastases. All patients were treated with a dose of 30 Gy in 3 fractions at 21-day intervals. We performed 62 hyperthermia procedures out of 75 planned (83 %). The aim of the hyperthermia treatment was to heat the prostate to 41-43 C for 60 min. Toxicity for the organs of the genitourinary system and rectum was assessed according to the Common Terminology Criteria for Adverse Events (CTCAE, v. 4.03). Determination of subsequent biochemical failure was based on the Phoenix definition (nadir + 2 ng/ml). The median age was 71 years (range 62-83 years), the median initial PSA level was 16.3 ng/ml (range 6.37-64 ng/ml), and the median salvage PSA level was 2.8 ng/ml (1.044-25.346 ng/ml). The median follow-up was 13 months (range 4-48 months). The combination of HDR brachytherapy and IHT was well tolerated. The most frequent complications were nocturia, weak urine stream, urinary frequency, hematuria, and urgency. Grade 2 rectal hemorrhage was observed in 1 patient. No grade 3 or higher complications were observed. The 2-year Kaplan-Meier estimate of biochemical control after salvage treatment was 74 %. The PSA in 20 patients decreased below the presalvage level, while 11 patients achieved a PSA nadir < 0.5 ng/ml. All patients are still alive. Of the 7 patients who experienced biochemical failure, bone metastases were found in 2 patients. IHT in combination

  8. Postenucleation orbits in retinoblastoma: treatment with 125I brachytherapy

    International Nuclear Information System (INIS)

    Stannard, Clare; Sealy, Ross; Hering, Egbert; Hough, Jan; Knowles, Ruth; Lecuona, Karin; Reddi, V. Bala

    2002-01-01

    Purpose: Children with retinoblastoma that extends into or through the choroid, sclera, or optic nerve are at risk of developing orbital disease, as well as metastases. Previously, these enucleated orbits were treated with external beam radiotherapy in addition to chemotherapy. 125 I brachytherapy for tumors in and around the eye was pioneered by Sealy in Cape Town, South Africa, in 1974. In 1983, he developed a technique to irradiate the contents of the orbit while limiting the dose to the bony orbit and eyelids. Methods and Materials: Six nylon tubes containing 125 I seeds were implanted through the eyelids around the periphery of the orbit. Each contained a metal gutter that screens the outer part of the seeds from the bony orbit. A seventh unscreened tube was placed in the center, and a metal disc with 125 I seeds on its posterior surface was secured beneath the eyelids. Between 1983 and 2000, 57 orbits were treated in 56 children with retinoblastoma. Thirty-six were treated prophylactically and 21, with tumor at the resection line of the nerve, extrascleral tumor, or metastases, were treated therapeutically. They received a median dose of 34 Gy in 70 h; 30 also received chemotherapy. Children with tumor at the resection line of the nerve also received treatment to the craniospinal axis. Results: The median follow-up of the 35 patients treated prophylactically was 35 months (range 0-187). Seven patients died, 6 of metastases, at a median of 10 months (range 4-29) after the implant. Eight of the 13 patients with microscopic extraocular tumor survived a median of 29 months (range 5-156). None of the 8 patients presenting with orbital tumor or metastases survived. No orbital recurrences developed in any of the patients. Cosmesis was considerably improved compared with previous forms of irradiation. Conclusion: Orbital brachytherapy is an effective method of irradiating the orbit to prevent recurrent tumor, the treatment time is short, and the cosmesis is much more

  9. Impact of Insurance Status on Radiation Treatment Modality Selection Among Potential Candidates for Prostate, Breast, or Gynecologic Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Grant, Stephen R. [Baylor College of Medicine, Houston, Texas (United States); Walker, Gary V. [Department of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, Texas (United States); Koshy, Matthew [Department of Radiation Oncology, The University of Chicago, Chicago, Illinois (United States); Shaitelman, Simona F.; Klopp, Ann H.; Frank, Steven J.; Pugh, Thomas J.; Allen, Pamela K. [Department of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, Texas (United States); Mahmood, Usama, E-mail: UMahmood@mdanderson.org [Department of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, Texas (United States)

    2015-12-01

    Purpose: The Patient Protection and Affordable Care Act looks to expand both private and Medicaid insurance. To evaluate how these changes may affect the field of radiation oncology, we evaluated the association of insurance status with the use of brachytherapy in cancers for which this treatment technique is used. Methods and Materials: A total of 190,467 patients met the inclusion criteria, of whom 95,292 (50.0%) had breast cancer, 61,096 (32.1%) had prostate cancer, 28,194 (14.8%) had endometrial cancer, and 5885 (3.1%) had cervical cancer. A multivariate logistic regression model was used to determine the association between insurance status and receipt of brachytherapy among patients treated definitively for prostate and cervical cancer or postoperatively for breast and endometrial cancer. Results: The rates of non-Medicaid insurance were 49.9% (cervical), 85.3% (endometrial), 87.4% (breast), and 90.9% (prostate) (P<.001). In a logistic regression, patients who received radiation therapy were less likely to receive brachytherapy if they had Medicaid coverage (odds ratio [OR] 0.57, 95% confidence interval [CI] 0.53-0.61, P<.001) or did not have insurance coverage (OR 0.50, 95% CI 0.45-0.56, P<.001) compared with those with non-Medicaid insurance. On subset analysis, patients with Medicaid coverage or without insurance coverage were significantly less likely to receive brachytherapy than were those with non-Medicaid insurance for all 4 sites, except for patients with endometrial cancer. Conclusions: Despite being a cost-effective treatment modality, brachytherapy is less often used in the definitive or postoperative management of cancer in patients with Medicaid coverage or without insurance. Upcoming health policy changes resulting in the expansion of private insurance and Medicaid will likely increase access to and demand for brachytherapy.

  10. Impact of Insurance Status on Radiation Treatment Modality Selection Among Potential Candidates for Prostate, Breast, or Gynecologic Brachytherapy

    International Nuclear Information System (INIS)

    Grant, Stephen R.; Walker, Gary V.; Koshy, Matthew; Shaitelman, Simona F.; Klopp, Ann H.; Frank, Steven J.; Pugh, Thomas J.; Allen, Pamela K.; Mahmood, Usama

    2015-01-01

    Purpose: The Patient Protection and Affordable Care Act looks to expand both private and Medicaid insurance. To evaluate how these changes may affect the field of radiation oncology, we evaluated the association of insurance status with the use of brachytherapy in cancers for which this treatment technique is used. Methods and Materials: A total of 190,467 patients met the inclusion criteria, of whom 95,292 (50.0%) had breast cancer, 61,096 (32.1%) had prostate cancer, 28,194 (14.8%) had endometrial cancer, and 5885 (3.1%) had cervical cancer. A multivariate logistic regression model was used to determine the association between insurance status and receipt of brachytherapy among patients treated definitively for prostate and cervical cancer or postoperatively for breast and endometrial cancer. Results: The rates of non-Medicaid insurance were 49.9% (cervical), 85.3% (endometrial), 87.4% (breast), and 90.9% (prostate) (P<.001). In a logistic regression, patients who received radiation therapy were less likely to receive brachytherapy if they had Medicaid coverage (odds ratio [OR] 0.57, 95% confidence interval [CI] 0.53-0.61, P<.001) or did not have insurance coverage (OR 0.50, 95% CI 0.45-0.56, P<.001) compared with those with non-Medicaid insurance. On subset analysis, patients with Medicaid coverage or without insurance coverage were significantly less likely to receive brachytherapy than were those with non-Medicaid insurance for all 4 sites, except for patients with endometrial cancer. Conclusions: Despite being a cost-effective treatment modality, brachytherapy is less often used in the definitive or postoperative management of cancer in patients with Medicaid coverage or without insurance. Upcoming health policy changes resulting in the expansion of private insurance and Medicaid will likely increase access to and demand for brachytherapy.

  11. Development of an adjoint sensitivity field-based treatment-planning technique for the use of newly designed directional LDR sources in brachytherapy.

    Science.gov (United States)

    Chaswal, V; Thomadsen, B R; Henderson, D L

    2012-02-21

    The development and application of an automated 3D greedy heuristic (GH) optimization algorithm utilizing the adjoint sensitivity fields for treatment planning to assess the advantage of directional interstitial prostate brachytherapy is presented. Directional and isotropic dose kernels generated using Monte Carlo simulations based on Best Industries model 2301 I-125 source are utilized for treatment planning. The newly developed GH algorithm is employed for optimization of the treatment plans for seven interstitial prostate brachytherapy cases using mixed sources (directional brachytherapy) and using only isotropic sources (conventional brachytherapy). All treatment plans resulted in V100 > 98% and D90 > 45 Gy for the target prostate region. For the urethra region, the D10(Ur), D90(Ur) and V150(Ur) and for the rectum region the V100cc, D2cc, D90(Re) and V90(Re) all are reduced significantly when mixed sources brachytherapy is used employing directional sources. The simulations demonstrated that the use of directional sources in the low dose-rate (LDR) brachytherapy of the prostate clearly benefits in sparing the urethra and the rectum sensitive structures from overdose. The time taken for a conventional treatment plan is less than three seconds, while the time taken for a mixed source treatment plan is less than nine seconds, as tested on an Intel Core2 Duo 2.2 GHz processor with 1GB RAM. The new 3D GH algorithm is successful in generating a feasible LDR brachytherapy treatment planning solution with an extra degree of freedom, i.e. directionality in very little time.

  12. Development of an adjoint sensitivity field-based treatment-planning technique for the use of newly designed directional LDR sources in brachytherapy

    Science.gov (United States)

    Chaswal, V.; Thomadsen, B. R.; Henderson, D. L.

    2012-02-01

    The development and application of an automated 3D greedy heuristic (GH) optimization algorithm utilizing the adjoint sensitivity fields for treatment planning to assess the advantage of directional interstitial prostate brachytherapy is presented. Directional and isotropic dose kernels generated using Monte Carlo simulations based on Best Industries model 2301 I-125 source are utilized for treatment planning. The newly developed GH algorithm is employed for optimization of the treatment plans for seven interstitial prostate brachytherapy cases using mixed sources (directional brachytherapy) and using only isotropic sources (conventional brachytherapy). All treatment plans resulted in V100 > 98% and D90 > 45 Gy for the target prostate region. For the urethra region, the D10Ur, D90Ur and V150Ur and for the rectum region the V100cc, D2cc, D90Re and V90Re all are reduced significantly when mixed sources brachytherapy is used employing directional sources. The simulations demonstrated that the use of directional sources in the low dose-rate (LDR) brachytherapy of the prostate clearly benefits in sparing the urethra and the rectum sensitive structures from overdose. The time taken for a conventional treatment plan is less than three seconds, while the time taken for a mixed source treatment plan is less than nine seconds, as tested on an Intel Core2 Duo 2.2 GHz processor with 1GB RAM. The new 3D GH algorithm is successful in generating a feasible LDR brachytherapy treatment planning solution with an extra degree of freedom, i.e. directionality in very little time.

  13. Genitourinary Toxicity After High-Dose-Rate (HDR) Brachytherapy Combined With Hypofractionated External Beam Radiotherapy for Localized Prostate Cancer: An Analysis to Determine the Correlation Between Dose-Volume Histogram Parameters in HDR Brachytherapy and Severity of Toxicity

    International Nuclear Information System (INIS)

    Ishiyama, Hiromichi; Kitano, Masashi; Satoh, Takefumi; Kotani, Shouko; Uemae, Mineko; Matsumoto, Kazumasa; Okusa, Hiroshi; Tabata, Ken-ichi; Baba, Shiro; Hayakawa, Kazushige

    2009-01-01

    Purpose: To evaluate the severity of genitourinary (GU) toxicity in high-dose-rate (HDR) brachytherapy combined with hypofractionated external beam radiotherapy (EBRT) for prostate cancer and to explore factors that might affect the severity of GU toxicity. Methods and Materials: A total of 100 Japanese men with prostate cancer underwent 192 Ir HDR brachytherapy combined with hypofractionated EBRT. Mean (SD) dose to 90% of the planning target volume was 6.3 (0.7) Gy per fraction of HDR. After 5 fractions of HDR treatment, EBRT with 10 fractions of 3 Gy was administrated. The urethral volume receiving 1-15 Gy per fraction in HDR brachytherapy (V1-V15) and the dose to at least 5-100% of urethral volume in HDR brachytherapy (D5-D100) were compared between patients with Grade 3 toxicity and those with Grade 0-2 toxicity. Prostate volume, patient age, and International Prostate Symptom Score were also compared between the two groups. Results: Of the 100 patients, 6 displayed Grade 3 acute GU toxicity, and 12 displayed Grade 3 late GU toxicity. Regarding acute GU toxicity, values of V1, V2, V3, and V4 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Regarding late GU toxicity, values of D70, D80, V12, and V13 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Conclusions: The severity of GU toxicity in HDR brachytherapy combined with hypofractionated EBRT for prostate cancer was relatively high. The volume of prostatic urethra was associated with grade of acute GU toxicity, and urethral dose was associated with grade of late GU toxicity.

  14. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co.

    Science.gov (United States)

    Reed, J L; Rasmussen, B E; Davis, S D; Micka, J A; Culberson, W S; DeWerd, L A

    2014-12-01

    To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for (125)I and (103)Pd brachytherapy sources relative to (60)Co. LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a (60)Co teletherapy source. The brachytherapy sources measured were the Best 2301 (125)I seed, the OncoSeed 6711 (125)I seed, and the Best 2335 (103)Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the (60)Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the (60)Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for (125)I and (103)Pd relative to (60)Co. The relative TLD intrinsic energy dependences (relative to (60)Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%-15% for (125)I and (103)Pd sources relative to (60)Co. TLD measurements of absolute dose around (125)I and (103)Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy.

  15. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co

    International Nuclear Information System (INIS)

    Reed, J. L.; Micka, J. A.; Culberson, W. S.; DeWerd, L. A.; Rasmussen, B. E.; Davis, S. D.

    2014-01-01

    Purpose: To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for 125 I and 103 Pd brachytherapy sources relative to 60 Co. Methods: LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a 60 Co teletherapy source. The brachytherapy sources measured were the Best 2301 125 I seed, the OncoSeed 6711 125 I seed, and the Best 2335 103 Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the 60 Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the 60 Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for 125 I and 103 Pd relative to 60 Co. Results: The relative TLD intrinsic energy dependences (relative to 60 Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. Conclusions: The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%–15% for 125 I and 103 Pd sources relative to 60 Co. TLD measurements of absolute dose around 125 I and 103 Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy

  16. Stereotactic iodine-125 brachytherapy for brain tumors: temporary versus permanent implantation

    Directory of Open Access Journals (Sweden)

    Ruge Maximilian I

    2012-06-01

    Full Text Available Abstract Stereotactic brachytherapy (SBT has been described in several publications as an effective, minimal invasive and safe highly focal treatment option in selected patients with well circumscribed brain tumors 40 cGy/h in combination with adjuvant external beam radiation and/or chemotherapy for the treatment of malignant gliomas and metastases resulted in increased rates of radiation induced adverse tissue changes requiring surgical intervention. Vice versa, such effects have been only minimally observed in numerous studies applying low dose rate (LDR regiments (3–8 cGy/h for low grade gliomas, metastases and other rare indications. Besides these observations, there are, however, no data available directly comparing the long term incidences of tissue changes after HDR and LDR and there is, furthermore, no evidence regarding a difference between temporary or permanent LDR implantation schemes. Thus, recommendations for effective and safe implantation schemes have to be investigated and compared in future studies.

  17. Acute exposure to Iodine-125: a case study

    Energy Technology Data Exchange (ETDEWEB)

    Kol, R; Canfi, A; Dukhan, N; Pelled, O; Brikner, D; Laichter, Y; Gold, B [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    Radioiodines I-125 and I-131 are extremely volatile even in the form of the relatively stable Iodine anion. This property renders frequent airborne contamination and sometimes accidental inhalation of the radioiodine by personnel heavily involved with it`s handling. In order to detect radioiodine contamination as early as possible, the laboratory and its surroundings are constantly air monitored, surfaces are monitored according to a predetermined regime and personnel is being checked upon completion of a job or upon leaving the laboratory. Follow-up, routine or in special occasions, is performed by health-physics personnel who reports to the radiation medicine department. We report here the measures and means used to monitor a case of an accidental inhalation of I-125 due to an externally contaminated NaI[I-125] commercial package. The monitoring of the contamination is described, the dose to the thyroid and the Committed Effective Dose Equivalent (CEDE) are reported, and the medical evaluation is presented (authors).

  18. Matched-pair analysis and dosimetric variations of two types of software for interstitial permanent brachytherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ishiyama, Hiromichi, E-mail: hishiyam@kitasato-u.ac.jp [Department of Radiology, Kitasato University School of Medicine, Sagamihara, Kanagawa (Japan); Nakamura, Ryuji [Department of Radiology, Iwate Medical University, Morioka, Iwate (Japan); Satoh, Takefumi [Department of Urology, Kitasato University School of Medicine, Sagamihara, Kanagawa (Japan); Tanji, Susumu [Department of Urology, Iwate Medical University, Morioka, Iwate (Japan); Teh, Bin S. [Department of Radiation Oncology, The Methodist Hospital, Houston, TX (United States); Uemae, Mineko [Division of Radiation Oncology, Kitasato University Hospital, Sagamihara, Kanagawa (Japan); Baba, Shiro [Department of Urology, Kitasato University School of Medicine, Sagamihara, Kanagawa (Japan); Hayakawa, Kazushige [Department of Radiology, Kitasato University School of Medicine, Sagamihara, Kanagawa (Japan)

    2012-04-01

    The purpose of this study was to determine whether identical dosimetric results could be achieved using different planning software for permanent interstitial brachytherapy for prostate cancer. Data from 492 patients treated with brachytherapy were used for matched-pair analysis. Interplant and Variseed were used as software for ultrasound-based treatment planning. Institution, neoadjuvant hormonal therapy, prostate volume, and source strength were used for factors to match the 2 groups. The study population comprised of 126 patients with treatment planning using Interplant software and 127 matched patients using Variseed software. Dosimetric results were compared between the 2 groups. The Variseed group showed significantly higher values for dose covering 90% of prostate volume (pD90), prostate volume covered by 150% of prescription dose (pV150), and dose covering 30% of the urethra (uD30) compared with the Interplant group. Our results showed that use of different software could lead to different dosimetric results, which might affect the clinical outcomes.

  19. Health-Related Quality of Life 2 Years After Treatment With Radical Prostatectomy, Prostate Brachytherapy, or External Beam Radiotherapy in Patients With Clinically Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Ferrer, Montserrat; Suarez, Jose Francisco; Guedea, Ferran; Fernandez, Pablo; Macias, Victor; Marino, Alfonso; Hervas, Asuncion; Herruzo, Ismael; Ortiz, Maria Jose; Villavicencio, Humberto; Craven-Bratle, Jordi; Garin, Olatz; Aguilo, Ferran

    2008-01-01

    Purpose: To compare treatment impact on health-related quality of life (HRQL) in patients with localized prostate cancer, from before treatment to 2 years after the intervention. Methods and Materials: This was a longitudinal, prospective study of 614 patients with localized prostate cancer treated with radical prostatectomy (134), three-dimensional external conformal radiotherapy (205), and brachytherapy (275). The HRQL questionnaires administered before and after treatment (months 1, 3, 6, 12, and 24) were the Medical Outcomes Study 36-Item Short Form, the Functional Assessment of Cancer Therapy (General and Prostate Specific), the Expanded Prostate Cancer Index Composite (EPIC), and the American Urological Association Symptom Index. Differences between groups were tested by analysis of variance and within-group changes by univariate repeated-measures analysis of variance. Generalized estimating equations (GEE) models were constructed to assess between-group differences in HRQL at 2 years of follow-up after adjusting for clinical variables. Results: In each treatment group, HRQL initially deteriorated after treatment with subsequent partial recovery. However, some dimension scores were still significantly lower after 2 years of treatment. The GEE models showed that, compared with the brachytherapy group, radical prostatectomy patients had worse EPIC sexual summary and urinary incontinence scores (-20.4 and -14.1; p < 0.001), and external radiotherapy patients had worse EPIC bowel, sexual, and hormonal summary scores (-3.55, -5.24, and -1.94; p < 0.05). Prostatectomy patients had significantly better EPIC urinary irritation scores than brachytherapy patients (+4.16; p < 0.001). Conclusions: Relevant differences between treatment groups persisted after 2 years of follow-up. Radical prostatectomy had a considerable negative effect on sexual functioning and urinary continence. Three-dimensional conformal radiotherapy had a moderate negative impact on bowel

  20. Edema associated with I-125 or Pd-103 prostate brachytherapy and its effect on post-implant dosimetry: an analysis based on serial CT acquisition

    International Nuclear Information System (INIS)

    Waterman, Frank M.; Yue Ning; Corn, Benjamin W.; Dicker, Adam P.

    1997-01-01

    Purpose/Objective: The dosimetric evaluation of prostate implants is based on analyses of post-implant CT scans. However, if the prostate is edematous as a consequence of needle insertion at the time of imaging, parameters such as dose coverage and the minimum prostatic dose may be underestimated. The purpose of this study is to characterize the magnitude and duration of post-implant edema, and its effect on dosimetry. Materials and Methods: Serial CT scans were obtained at 0, 1, 3, 7, and 15 weeks post-implant on 10 patients who received either I-125 or Pd-103 seed implants. Pre-implant CT scans of each prostate were also obtained. None of the patients received hormone therapy. The magnitude and duration of edema were evaluated by two different methods. In the first, the relative change in the prostate dimensions was determined from the change in the spatial distribution of the implanted seeds, which contract as edema decreases. The radial distance of each seed from the geometric center of the seed cluster was first calculated and then the mean value was computed. The relative change in the mean radial distance in the serial CT scans reflects the relative change in the prostate dimensions. In the second, the prostate in each CT scan was contoured by the same individual, and the prostate volume was computed. A dose-volume histogram of each contoured volume was compiled, from which the minimum prostatic dose and the percentage of the prostate volume which received the prescribed dose were determined. Results: Edema was present in all of the implanted prostates. The magnitude of the edema, expressed as the ratio of the post- to pre-implant volume, ranged from 1.25 to 1.70 (mean 1.47) immediately after implantation. Both methodologies revealed that the edema decreased exponentially with time; however, the edema half-life (time for the edema to decrease by (1(2))) varied considerably, ranging from 3 to 23 days (mean 8.5 days). As edema regressed, the minimum prostatic

  1. Combined transperineal radiofrequency (RF) interstitial hyperthermia and brachytherapy for localized prostate cancer (PC)

    International Nuclear Information System (INIS)

    Urakami, Shinji; Gonda, Nobuko; Kikuno, Nobuyuki

    2001-01-01

    Hyperthermia has been used effectively as a radiation sensitizer. Interstitial hyperthermoradiotherapy has been therefore utilized as a minimal invasive therapy in attempts to improve local tumor control for various cancers, but not for urological cancer. The purpose of this study was to investigate the safety and feasibility of transperineal hyperthermoradiotherapy for localized PC. Based on our basic study of hyperthermoradiotherapy, we devised the procedure of combined transperineal RF interstitial hyperthermia and brachytherapy for localized prostate cancer. Two patients with localized PC underwent transperineal RF interstitial hyperthermia combined with brachytherapy operation the 192-Ir remote after-loading system (RALS). Under transrectal ultrasound guidance, a total number of 12-18 stainless steel needles for 192-Ir RALS were implanted into the prostatic gland and seminal vesicles (SV) in an optimized pattern. Eight of the needles were used as electrodes for hyperthermia, and were electrically insultated using the vinyl catheter along the length of the subdermal fatty tissue to protect from overheating. Three other needles were utilized for continuous temperature mapping in the prostate. Rectal temperature was also monitored. Total radiation doses of 70 Gy to the prostate and SV were planned as a combination of brachytherapy (24 Gy/4 fraction) and external irradiation using a four-field box technique (46 Gy/23 fraction). Hyperthermic treatment (goal of 42 to 43 deg C for 60 minutes) was performed twice following the 1st and 4th brachytherapy at an interval of more than 48 hours for the recovery of cancer cells from thermotolerance. Both patients reached the treatment goal of all intraprostatic temperatures >43.0 deg C, which was considered favorable for hyperthermia, and the rectal temperatures of both patients remained <38 deg C during hyperthermia. In serial PSA measurements of both patients, serum PSA was less than 1.0 ng/ml within 3 months and has since

  2. Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds

    OpenAIRE

    Lediju Bell, Muyinatu A.; Kuo, Nathanael; Song, Danny Y.; Boctor, Emad M.

    2013-01-01

    Prostate brachytherapy, administered by implanting tiny radioactive seeds to treat prostate cancer, currently relies on transrectal ultrasound imaging for intraoperative visualization of the metallic seeds. Photoacoustic (PA) imaging has been suggested as a feasible alternative to ultrasound imaging due to its superior sensitivity to metal surrounded by tissue. However, PA images suffer from poor contrast when seeds are distant from the light source. We propose a transperineal light delivery ...

  3. A comprehensive review of prostate cancer brachytherapy: defining an optimal technique

    International Nuclear Information System (INIS)

    Vicini, Frank A.; Kini, Vijay R.; Edmundson, Gregory B.S.; Gustafson, Gary S.; Stromberg, Jannifer; Martinez, Alvaro

    1999-01-01

    Purpose: A comprehensive review of prostate cancer brachytherapy literature was performed to determine if an optimal method of implantation could be identified, and to compare and contrast techniques currently in use. Methods and Materials: A MEDLINE search was conducted to obtain all articles in the English language on prostate cancer brachytherapy from 1985 through 1998. Articles were reviewed and grouped to determine the primary technique of implantation, the method or philosophy of source placement and/or dose specification, the technique to evaluate implant quality, overall treatment results (based upon pretreatment prostate specific antigen, (PSA), and biochemical control) and clinical, pathological or biochemical outcome based upon implant quality. Results: A total of 178 articles were identified in the MEDLINE database. Of these, 53 studies discussed evaluable techniques of implantation and were used for this analysis. Of these studies, 52% used preoperative ultrasound to determine the target volume to be implanted, 16% used preoperative computerized tomography (CT) scans, and 18% placed seeds with an open surgical technique. An additional 11% of studies placed seeds or needles under ultrasound guidance using interactive real-time dosimetry. The number and distribution of radioactive sources to be implanted or the method used to prescribe dose was determined using nomograms in 27% of studies, a least squares optimization technique in 11%, or not stated in 35%. In the remaining 26%, sources were described as either uniformly, differentially, or peripherally placed in the gland. To evaluate implant quality, 28% of studies calculated some type of dose-volume histogram, 21% calculated the matched peripheral dose, 19% the minimum peripheral dose, 14% used some type of CT-based qualitative review and, in 18% of studies, no implant quality evaluation was mentioned. Six studies correlated outcome with implant dose. One study showed an association of implant dose

  4. High and intermediate risk prostate cancer treated with three-dimensional computed tomography-guided brachytherapy: 2-8-year follow-up

    International Nuclear Information System (INIS)

    Koutrouvelis, Panos G.; Gillenwater, Jay; Lailas, Niko; Hendricks, Fred; Katz, Stuart; Sehn, James; Gil-Montero, Guillermo; Khawand, Nabil

    2003-01-01

    Purpose: To report post-brachytherapy results in high and intermediate risk patients of prostatic adenocarcinoma. Methods and materials: From June 1994 to June 2000, 356 consecutive high and intermediate risk patients were treated with three-dimensional computed tomography-guided stereotactic pararectal brachytherapy. The age was 42-90 years (median, 68 years), the initial prostate volume was 14-180 cm 3 (median, 59 cm 3 ), and initial PSA was 1.7-143 ng/ml (median, 10.5 ng/ml). Three hundred forty-eight patients were available for follow-up for 2 - 8 years (median, 4.5 years). Two hundred eighty patients had one or more high risk factors (PSA >20 ng/ml, Gleason>7, Stage T2b, T3a, or T3b). Sixty-eight patients had only one intermediate risk factor (PSA 10-20 ng/ml or Gleason=7). Patients with both intermediate risks were considered high risk. The high-risk group was further stratified into subgroups with similar risk profile. A dose of 144 Gy with 125 I or 120 Gy with 103 Pd was achieved in 90-100% of the target. Thirty (30) patients (9%) had prior transurethral resection and 229 (64%) were treated with 3 months neoadjuvant androgen ablation. Results: Biochemical disease-free survival was 92% of 280 high risk patients and 96% of 68 intermediate risk patients. Seven patients (2%) required catheterization during the first year for urinary retention, nine patients (3%) required TUR 1-3 years post-implant, three patients (1%) developed grade 1 or 2 incontinence after a second TUR, and four patients (1%) developed grade 3 rectal complications. Conclusion: This method produces a high level of biochemical control 2-8 years (median 4.5 years). Morbidity is acceptable regardless of risk profile or initial prostate volume

  5. Survival benefit of chemoembolization plus Iodine125 seed implantation in unresectable hepatitis B-related hepatocellular carcinoma with PVTT: a retrospective matched cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Mingsheng; Wang, Haofan; Chen, Junwei; Bai, Mingjun; Wang, Long; Zhu, Kangshun; Jiang, Zaibo; Guan, Shouhai; Li, Zhengran; Qian, Jiesheng; Li, Mingan; Pang, Pengfei; Shan, Hong [Sun Yat-sen University, Department of Radiology, the Third Affiliated Hospital, Guangzhou (China); Sun Yat-Sen University, Department of Interventional Radiology, Ling-nan Hospital, Guangzhou (China); Sun Yat-sen University, Interventional Radiology Institute, Guangzhou (China); Lin, Qu [Sun Yat-sen University, Department of Oncology, the Third Affiliated Hospital, Guangzhou (China)

    2016-10-15

    To investigate the survival benefit of transarterial chemoembolization (TACE) plus Iodine125 seed implantation (TACE-Iodine125) in hepatitis B-related HCC patients with portal vein tumour thrombus (PVTT) and the underlying prognostic factors. A retrospective matched cohort study was performed on consecutive HCC patients with PVTT from January 2011 to June 2014. Seventy patients (TACE-Iodine125 group) who underwent TACE-Iodine125 were compared with a historical case-matched control group of 140 patients (TACE group) who received TACE alone. The survival of patients and the underlying prognostic factors were analysed. The median survival times of the TACE-Iodine125 and TACE groups were 11.0 and 7.5 months, respectively (p < 0.001). The survival probability at 12, 24, and 36 months was 50 %, 14.5 %, and 14.5 % vs. 25 %, 9 %, and 5 % in the TACE-Iodine125 and TACE groups, respectively (p < 0.001). The PVTT responders had better survival than the PVTT non-responders (p < 0.001). For the PVTT non-responders, there were no differences in the survival curves between the groups (p = 0.353). Multivariate analysis showed that type III PVTT (p < 0.001) and APS (p < 0.001) were independent predictors of poor prognosis. In contrast, the treatment modality of TACE-Iodine125 (p < 0.001) and PVTT response (p = 0.001) were favourable prognostic features. TACE combined with Iodine125 seed implantation may be a good choice for selected HB-HCC patients with PVTT. (orig.)

  6. Spectroscopic output of {sup 125}I and {sup 103}Pd low dose rate brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Usher-Moga, Jacqueline; Beach, Stephen M.; DeWerd, Larry A. [Department of Medical Physics, University of Wisconsin--Madison, Madison, Wisconsin 53705 (United States); Global Physics Solutions, St. Joseph, Michigan 49085 (United States); Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2009-01-15

    The spectroscopic output of low dose rate (LDR) brachytherapy sources is dependent on the physical design and construction of the source. Characterization of the emitted photons from 12 {sup 125}I and 3 {sup 103}Pd LDR brachytherapy source models is presented. Photon spectra, both along the transverse bisector and at several polar angles, were measured in air with a high-purity reverse electrode germanium (REGe) detector. Measured spectra were corrected to in vacuo conditions via Monte Carlo and analytical methods. The tabulated and plotted spectroscopic data provide a more complete understanding of each source model's output characteristics than can be obtained with other measurement techniques. The variation in fluorescence yield of the {sup 125}I sources containing silver caused greater differences in the emitted spectra and average energies among these seed models than was observed for the {sup 103}Pd sources or the {sup 125}I sources that do not contain silver. Angular spectroscopic data further highlighted the effects of source construction unique to each model, as well as the asymmetric output of many seeds. These data demonstrate the need for the incorporation of such physically measured output characteristics in the Monte Carlo modeling process.

  7. Robot-assisted 3D-TRUS guided prostate brachytherapy: System integration and validation

    International Nuclear Information System (INIS)

    Wei Zhouping; Wan Gang; Gardi, Lori; Mills, Gregory; Downey, Donal; Fenster, Aaron

    2004-01-01

    Current transperineal prostate brachytherapy uses transrectal ultrasound (TRUS) guidance and a template at a fixed position to guide needles along parallel trajectories. However, pubic arch interference (PAI) with the implant path obstructs part of the prostate from being targeted by the brachytherapy needles along parallel trajectories. To solve the PAI problem, some investigators have explored other insertion trajectories than parallel, i.e., oblique. However, parallel trajectory constraints in current brachytherapy procedure do not allow oblique insertion. In this paper, we describe a robot-assisted, three-dimensional (3D) TRUS guided approach to solve this problem. Our prototype consists of a commercial robot, and a 3D TRUS imaging system including an ultrasound machine, image acquisition apparatus and 3D TRUS image reconstruction, and display software. In our approach, we use the robot as a movable needle guide, i.e., the robot positions the needle before insertion, but the physician inserts the needle into the patient's prostate. In a later phase of our work, we will include robot insertion. By unifying the robot, ultrasound transducer, and the 3D TRUS image coordinate systems, the position of the template hole can be accurately related to 3D TRUS image coordinate system, allowing accurate and consistent insertion of the needle via the template hole into the targeted position in the prostate. The unification of the various coordinate systems includes two steps, i.e., 3D image calibration and robot calibration. Our testing of the system showed that the needle placement accuracy of the robot system at the 'patient's' skin position was 0.15 mm±0.06 mm, and the mean needle angulation error was 0.07 deg. . The fiducial localization error (FLE) in localizing the intersections of the nylon strings for image calibration was 0.13 mm, and the FLE in localizing the divots for robot calibration was 0.37 mm. The fiducial registration error for image calibration was 0

  8. Potency after permanent prostate brachytherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Potters, Louis; Torre, Taryn; Fearn, Paul A.; Leibel, Steven A.; Kattan, Michael W.

    2001-01-01

    Purpose: The evaluation of potency preservation after treatment of localized prostate cancer with transperineal permanent prostate brachytherapy (PPB) and the efficacy of sildenafil were studied. Methods and Materials: This study comprised 482 patients who were able to maintain an erection suitable for intercourse before treatment from a cohort of 1166 patients with clinically localized prostate cancer treated with PPB. All patients have been followed prospectively, and actuarial analysis was performed to assess potency preservation over time. Patients treated with sildenafil were evaluated as to its efficacy. Results: The median follow-up of this cohort was 34 months (6-92), with a median age of 68 years (47-80). Potency was preserved in 311 of the 482 patients, with a 5-year actuarial potency rate of 52.7%. The 5-year actuarial potency rate for patients treated with PPB as monotherapy was 76%, and, for those treated with combination external beam radiotherapy (EBT) + PPB, 56% (p=0.08). Patients treated with neoadjuvant androgen deprivation (NAAD) + PPB had a 5-year potency rate of 52%, whereas those with combination EBT + PPB + NAAD had a potency rate of 29% (p=0.13). Cox regression analysis identified that pretreatment use of NAAD and patient age predicted for impotence (p=0.0001 and 0.04, respectively). Of 84 patients treated with sildenafil, 52 had a successful outcome (62%). The response to sildenafil was significantly better in those patients not treated with NAAD (p=0.04). Conclusions: The actuarial potency rates at 5 years for patients treated with PPB are lower than generally acknowledged, except for those patients treated with PPB as monotherapy. Patients who received sildenafil exhibited improved potency in a majority of cases

  9. Factors predicting for postimplantation urinary retention after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Lee, Nancy; Wuu, C.-S.; Brody, Rachel; Laguna, Joe L.; Katz, Aaron E.; Bagiella, Emilia; Ennis, Ronald D.

    2000-01-01

    Purpose: Urinary retention requiring catheterization is a known complication among prostate cancer patients treated with permanent interstitial radioactive seed implantation. However, the factors associated with this complication are not well known. This study was conducted to determine these factors. Methods and Materials: Ninety-one consecutive prostate cancer patients treated with permanent interstitial implantation at our institution from 1996 to 1999 were evaluated. All patients underwent pre-implant ultrasound and postimplant CT volume studies. Isotopes used were 125 I (54 patients) or 103 Pd (37 patients). Twenty-three patients were treated with a combination of 45 Gy of external beam radiation therapy as well as seed implantation, of which only 3 patients were treated with 125 I. Mean pretreatment prostate ultrasound volume was 35.4 cc (range, 10.0-70.2 cc). The mean planning ultrasound target volume (PUTV) was 39.6 cc (range, 16.1-74.5 cc), whereas the mean posttreatment CT target volume was 55.0 cc (range, 20.2-116 cc). Patient records were reviewed to determine which patients required urinary catheterization for relief of urinary obstruction. The following factors were analyzed as predictors for urinary retention: clinical stage; Gleason score; prostate-specific antigen; external beam radiation therapy; hormone therapy; pre-implant urinary symptoms (asymptomatic/nocturia x 1 vs. more significant urinary symptoms); pretreatment ultrasound prostate volume; PUTV; PUTV within the 125%, 150%, 200%, 250%, 300% isodose lines; postimplant CT volume within the 125%, 150%, 200%, 250%, 300% isodose lines; D90; D80; D50; ratio of post-CT volume to the PUTV; the absolute change in volume between the CT volume and PUTV; number of needles used; activity per seed; and the total activity of the implant. Statistical analyses using logistic regression and χ2 were performed. Results: Eleven of 91 (12%) became obstructed. Significant factors predicting for urinary retention

  10. Urethra-Sparing, Intraoperative, Real-Time Planned, Permanent-Seed Prostate Brachytherapy: Toxicity Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zilli, Thomas [Department of Radiation Oncology, Centre hospitalier de l' Universite de Montreal-Hopital Notre-Dame, Montreal, QC (Canada); Taussky, Daniel, E-mail: daniel.taussky.chum@ssss.gouv.qc.ca [Department of Radiation Oncology, Centre hospitalier de l' Universite de Montreal-Hopital Notre-Dame, Montreal, QC (Canada); Donath, David; Le, Hoa Phong; Larouche, Renee-Xaviere; Beliveau-Nadeau, Dominique; Hervieux, Yannick; Delouya, Guila [Department of Radiation Oncology, Centre hospitalier de l' Universite de Montreal-Hopital Notre-Dame, Montreal, QC (Canada)

    2011-11-15

    Purpose: To report the toxicity outcome in patients with localized prostate cancer undergoing {sup 125}I permanent-seed brachytherapy (BT) according to a urethra-sparing, intraoperative (IO), real-time planned conformal technique. Methods and Materials: Data were analyzed on 250 patients treated consecutively for low- or intermediate-risk prostate cancer between 2005 and 2009. The planned goal was urethral V{sub 150} = 0. Acute and late genitourinary (GU), gastrointestinal (GI), and erectile toxicities were scored with the International Prostate Symptom Score (IPSS) questionnaire and Common Terminology Criteria for Adverse Events (version 3.0). Median follow-up time for patients with at least 2 years of follow-up (n = 130) was 34.4 months (range, 24-56.9 months). Results: Mean IO urethra V{sub 150} was 0.018% {+-} 0.08%. Mean prostate D{sub 90} and V{sub 100} on day-30 computed tomography scan were 158.0 {+-} 27.0 Gy and 92.1% {+-} 7.2%, respectively. Mean IPSS peak was 9.5 {+-} 6.3 1 month after BT (mean difference from baseline IPSS, 5.3). No acute GI toxicity was observed in 86.8% of patients. The 3-year probability of Grade {>=}2 late GU toxicity-free survival was 77.4% {+-} 4.0%, with Grade 3 late GU toxicity encountered in only 3 patients. Three-year Grade 1 late GI toxicity-free survival was 86.1% {+-} 3.2%. No patient presented Grade {>=}2 late GI toxicity. Of patients with normal sexual status at baseline, 20.7% manifested Grade {>=}2 erectile dysfunction after BT. On multivariate analysis, elevated baseline IPSS (p = 0.016) and high-activity sources (median 0.61 mCi) (p = 0.033) predicted increased Grade {>=}2 late GU toxicity. Conclusions: Urethra-sparing IO BT results in low acute and late GU toxicity compared with the literature. High seed activity and elevated IPSS at baseline increased long-term GU toxicity.

  11. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  12. Dosimetric impact of dual-energy CT tissue segmentation for low-energy prostate brachytherapy: a Monte Carlo study

    Science.gov (United States)

    Remy, Charlotte; Lalonde, Arthur; Béliveau-Nadeau, Dominic; Carrier, Jean-François; Bouchard, Hugo

    2018-01-01

    The purpose of this study is to evaluate the impact of a novel tissue characterization method using dual-energy over single-energy computed tomography (DECT and SECT) on Monte Carlo (MC) dose calculations for low-dose rate (LDR) prostate brachytherapy performed in a patient like geometry. A virtual patient geometry is created using contours from a real patient pelvis CT scan, where known elemental compositions and varying densities are overwritten in each voxel. A second phantom is made with additional calcifications. Both phantoms are the ground truth with which all results are compared. Simulated CT images are generated from them using attenuation coefficients taken from the XCOM database with a 100 kVp spectrum for SECT and 80 and 140Sn kVp for DECT. Tissue segmentation for Monte Carlo dose calculation is made using a stoichiometric calibration method for the simulated SECT images. For the DECT images, Bayesian eigentissue decomposition is used. A LDR prostate brachytherapy plan is defined with 125I sources and then calculated using the EGSnrc user-code Brachydose for each case. Dose distributions and dose-volume histograms (DVH) are compared to ground truth to assess the accuracy of tissue segmentation. For noiseless images, DECT-based tissue segmentation outperforms the SECT procedure with a root mean square error (RMS) on relative errors on dose distributions respectively of 2.39% versus 7.77%, and provides DVHs closest to the reference DVHs for all tissues. For a medium level of CT noise, Bayesian eigentissue decomposition still performs better on the overall dose calculation as the RMS error is found to be of 7.83% compared to 9.15% for SECT. Both methods give a similar DVH for the prostate while the DECT segmentation remains more accurate for organs at risk and in presence of calcifications, with less than 5% of RMS errors within the calcifications versus up to 154% for SECT. In a patient-like geometry, DECT-based tissue segmentation provides dose

  13. MicroRNA-125a-5p regulates cancer cell proliferation and migration through NAIF1 in prostate carcinoma.

    Science.gov (United States)

    Fu, Yi; Cao, Fuhua

    2015-01-01

    We investigated the functional roles of microRNA-125a-5p in regulating human prostate carcinoma. Quantitative reverse transcription-polymerase chain reaction (qRT-PCR) was conducted to evaluate the gene expression levels of miR-125a-5p in eight prostate cancer cell lines and nine biopsy specimens from patients with prostate cancer. miR-125a-5p was genetically knocked down in prostate cancer cell lines, DU145 and VCaP cells by lentiviral transduction. The effects of miR-125a-5p downregulation on prostate cancer cell proliferation and migration were evaluated by MTT assay and transwell assay, respectively. Direct regulation of miR-125a-5p on its downstream targets, NAIF1, and apoptotic gene caspase-3 were evaluated through dual-luciferase reporter assay, qRT-PCR, and Western blot, respectively. NAIF1 was then ectopically overexpressed in DU145 and VCaP cells to modulate prostate cancer cell proliferation and migration. Finally, the effects of miR-125a-5p downregulation or NAIF1 overexpression on the growth of in vivo prostate cancer xenograft were evaluated. miR-125a-5p was upregulated in prostate cancer cell lines and human prostate carcinomas. Lentivirus induced miR-125a-5p downregulation in DU145 and VCaP cells inhibited prostate cancer cell proliferation or migration. NAIF1 was the direct target of miR-125a-5p, as both gene and protein expression levels of NAIF1, as well as caspase-3 were upregulated by miR-125a-5p. Forced overexpression of NAIF1 had similar antitumor effects as miR-125a-5p downregulation on prostate cancer cell proliferation and migration. In vivo prostate xenograft assay confirmed the tumor-suppressive effect of miR-125a-5p downregulation or NAIF1 overexpression. miR-125a-5p regulates prostate cancer cell proliferation and migration through NAIF1.

  14. Fast GPU-based Monte Carlo simulations for LDR prostate brachytherapy

    Science.gov (United States)

    Bonenfant, Éric; Magnoux, Vincent; Hissoiny, Sami; Ozell, Benoît; Beaulieu, Luc; Després, Philippe

    2015-07-01

    The aim of this study was to evaluate the potential of bGPUMCD, a Monte Carlo algorithm executed on Graphics Processing Units (GPUs), for fast dose calculations in permanent prostate implant dosimetry. It also aimed to validate a low dose rate brachytherapy source in terms of TG-43 metrics and to use this source to compute dose distributions for permanent prostate implant in very short times. The physics of bGPUMCD was reviewed and extended to include Rayleigh scattering and fluorescence from photoelectric interactions for all materials involved. The radial and anisotropy functions were obtained for the Nucletron SelectSeed in TG-43 conditions. These functions were compared to those found in the MD Anderson Imaging and Radiation Oncology Core brachytherapy source registry which are considered the TG-43 reference values. After appropriate calibration of the source, permanent prostate implant dose distributions were calculated for four patients and compared to an already validated Geant4 algorithm. The radial function calculated from bGPUMCD showed excellent agreement (differences within 1.3%) with TG-43 accepted values. The anisotropy functions at r = 1 cm and r = 4 cm were within 2% of TG-43 values for angles over 17.5°. For permanent prostate implants, Monte Carlo-based dose distributions with a statistical uncertainty of 1% or less for the target volume were obtained in 30 s or less for 1 × 1 × 1 mm3 calculation grids. Dosimetric indices were very similar (within 2.7%) to those obtained with a validated, independent Monte Carlo code (Geant4) performing the calculations for the same cases in a much longer time (tens of minutes to more than a hour). bGPUMCD is a promising code that lets envision the use of Monte Carlo techniques in a clinical environment, with sub-minute execution times on a standard workstation. Future work will explore the use of this code with an inverse planning method to provide a complete Monte Carlo-based planning solution.

  15. An analysis of brachytherapy with computed tomography-guided permanent implantation of Iodine-125 seeds for recurrent nonkeratin nasopharyngeal carcinoma

    Directory of Open Access Journals (Sweden)

    Shen X

    2015-05-01

    Full Text Available Xinying Shen,1,2 Yong Li,2 Yanfang Zhang,2 Jian Kong,2 Yanhao Li1 1Department of Interventional Radiology, Nanfang Hospital, Southern Medical University, Guangzhou, 2Department of Interventional Radiology, Shenzhen People’s Hospital, The Second Clinical Medical College of Jinan University, Shenzhen, People’s Republic of China Background: 125I seed implantation is a new method in treatment of nasopharyngeal carcinoma (NPC, and it is worthwhile to evaluate its feasibility. In this study, we performed brachytherapy with computed tomography (CT-guided permanent implantation of 125I seeds in the treatment of patients with the recurrence of NPC.Methods: A total 30 patients (20 male and ten female at the median age of 55 (range 25–80 years were diagnosed with recurrent nonkeratin NPC, with a total 38 lesions and a short disease-free interval (median ~11 months after primary radiotherapy alone or combined with chemotherapy. Patients received CT scan, starting from 2 months after the treatment. Follow-up was conducted for ~2–38 months to observe the local control rate and overall survival rate. We also analyzed the possible correlation between survival periods and the status of recurrent tumors.Results: The local control rates at 6, 12, 24, 30, and 36 months after the procedure of 125I seed implantation were 86.8%, 73.7%, 26.3%, 15.8%, and 5.3%, respectively. The overall 1-, 2-, and 3-year survival rates were 80.0% (24/30, 30.0% (9/30, and 6.7% (2/30, respectively, with a median survival period of 18 months (17.6±8.6 months. Interestingly, the survival periods of the patients who had primary radiotherapy with or without chemotherapy were 15.8±7.9 and 24.3±7.9 months, respectively. Kaplan–Meier survival analysis demonstrated that χ2 (log rank was 7.555, with very significant difference (P<0.01. The survival periods of patients in tumor stages I, II, III, and IV were 25.4±8.7, 19.8±9.4, 16.1±4.5, and 12.8±7.8 months, respectively, with

  16. Predictive Factors and Management of Rectal Bleeding Side Effects Following Prostate Cancer Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Price, Jeremy G. [Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, New York (United States); Stone, Nelson N. [Department of Urology, Icahn School of Medicine at Mount Sinai, New York, New York (United States); Stock, Richard G., E-mail: Richard.Stock@mountsinai.org [Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, New York (United States)

    2013-08-01

    Purpose: To report on the incidence, nature, and management of rectal toxicities following individual or combination brachytherapy following treatment for prostate cancer over a 17-year period. We also report the patient and treatment factors predisposing to acute ≥grade 2 proctitis. Methods and Materials: A total of 2752 patients were treated for prostate cancer between October 1990 and April 2007 with either low-dose-rate brachytherapy alone or in combination with androgen depletion therapy (ADT) or external beam radiation therapy (EBRT) and were followed for a median of 5.86 years (minimum 1.0 years; maximum 19.19 years). We investigated the 10-year incidence, nature, and treatment of acute and chronic rectal toxicities following BT. Using univariate, and multivariate analyses, we determined the treatment and comorbidity factors predisposing to rectal toxicities. We also outline the most common and effective management for these toxicities. Results: Actuarial risk of ≥grade 2 rectal bleeding was 6.4%, though notably only 0.9% of all patients required medical intervention to manage this toxicity. The majority of rectal bleeding episodes (72%) occurred within the first 3 years following placement of BT seeds. Of the 27 patients requiring management for their rectal bleeding, 18 underwent formalin treatment and nine underwent cauterization. Post-hoc univariate statistical analysis revealed that coronary artery disease (CAD), biologically effective dose, rectal volume receiving 100% of the prescription dose (RV100), and treatment modality predict the likelihood of grade ≥2 rectal bleeding. Only CAD, treatment type, and RV100 fit a Cox regression multivariate model. Conclusions: Low-dose-rate prostate brachytherapy is very well tolerated and rectal bleeding toxicities are either self-resolving or effectively managed by medical intervention. Treatment planning incorporating adjuvant ADT while minimizing RV100 has yielded the best toxicity-free survival following

  17. A study of optimization techniques in HDR brachytherapy for the prostate

    Science.gov (United States)

    Pokharel, Ghana Shyam

    Several studies carried out thus far are in favor of dose escalation to the prostate gland to have better local control of the disease. But optimal way of delivery of higher doses of radiation therapy to the prostate without hurting neighboring critical structures is still debatable. In this study, we proposed that real time high dose rate (HDR) brachytherapy with highly efficient and effective optimization could be an alternative means of precise delivery of such higher doses. This approach of delivery eliminates the critical issues such as treatment setup uncertainties and target localization as in external beam radiation therapy. Likewise, dosimetry in HDR brachytherapy is not influenced by organ edema and potential source migration as in permanent interstitial implants. Moreover, the recent report of radiobiological parameters further strengthen the argument of using hypofractionated HDR brachytherapy for the management of prostate cancer. Firstly, we studied the essential features and requirements of real time HDR brachytherapy treatment planning system. Automating catheter reconstruction with fast editing tools, fast yet accurate dose engine, robust and fast optimization and evaluation engine are some of the essential requirements for such procedures. Moreover, in most of the cases we performed, treatment plan optimization took significant amount of time of overall procedure. So, making treatment plan optimization automatic or semi-automatic with sufficient speed and accuracy was the goal of the remaining part of the project. Secondly, we studied the role of optimization function and constraints in overall quality of optimized plan. We have studied the gradient based deterministic algorithm with dose volume histogram (DVH) and more conventional variance based objective functions for optimization. In this optimization strategy, the relative weight of particular objective in aggregate objective function signifies its importance with respect to other objectives

  18. Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches

    Science.gov (United States)

    Song, Sang-Eun; Cho, Nathan B.; Fischer, Gregory; Hata, Nobuhito; Tempany, Clare; Fichtinger, Gabor; Iordachita, Iulian

    2011-01-01

    Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained. PMID:21399734

  19. Detailed urethral dosimetry in the evaluation of prostate brachytherapy-related urinary morbidity

    International Nuclear Information System (INIS)

    Allen, Zachariah A.; Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Kurko, Brian; Anderson, Richard L.; Murray, Brian C.; Galbreath, Robert W.

    2005-01-01

    Purpose: To evaluate the relationship between urinary morbidity after prostate brachytherapy and urethral doses calculated at the base, midprostate, apex, and urogenital diaphragm. Methods and Materials: From February 1998 through July 2002, 186 consecutive patients without a prior history of a transurethral resection underwent monotherapeutic brachytherapy (no supplemental external beam radiation therapy or androgen deprivation therapy) with urethral-sparing techniques (average urethral dose 100%-140% minimum peripheral dose) for clinical T1c-T2b (2002 AJCC) prostate cancer. The median follow-up was 45.5 months. Urinary morbidity was defined by time to International Prostate Symptom Score (IPSS) resolution, maximum increase in IPSS, catheter dependency, and the need for postimplant surgical intervention. An alpha blocker was initiated approximately 2 weeks before implantation and continued at least until the IPSS returned to baseline. Evaluated parameters included overall urethral dose (average and maximum), doses to the base, midprostate, apex, and urogenital diaphragm, patient age, clinical T stage, preimplant IPSS, ultrasound volume, isotope, and D90 and V100/150/200. Results: Of the 186 patients, 176 (94.6%) had the urinary catheter permanently removed on the day of implantation with only 1 patient requiring a urinary catheter >5 days. No patient had a urethral stricture and only 2 patients (1.1%) required a postbrachytherapy transurethral resection of the prostate (TURP). For the entire cohort, IPSS on average peaked 2 weeks after implantation with a mean and median time to IPSS resolution of 14 and 3 weeks, respectively. For the entire cohort, only isotope predicted for IPSS resolution, while neither overall average prostatic urethra nor segmental urethral dose predicted for IPSS resolution. The maximum postimplant IPSS increase was best predicted by preimplant IPSS and the maximum apical urethral dose. Conclusions: With the routine use of prophylactic alpha

  20. Seed displacements after permanent brachytherapy for prostate cancer in dependence on the prostate level

    Energy Technology Data Exchange (ETDEWEB)

    Pinkawa, M.; Gagel, B.; Asadpour, B.; Piroth, M.D.; Klotz, J.; Eble, M.J. [Dept. of Radiotherapy, RWTH Aachen (Germany); Borchers, H.; Jakse, G. [Dept. of Urology, RWTH Aachen (Germany)

    2008-10-15

    Purpose: to evaluate seed displacements after permanent prostate brachytherapy considering different prostate levels. Patients and methods: in 61 patients, postimplant CT scans were performed 1 day and 1 month after an implant with stranded seeds. Seed and prostate surface displacements were determined relative to pelvic bones. Four groups of seed locations were selected: seeds at the base (n = 305; B), at the apex (n = 305; A), close to the urethra (n = 306; U), and close to the rectal wall (n = 204; R). The length of two strands (always containing four seeds) per patient was measured in all CT scans and compared. Results: the largest inferior seed displacements were found at the base: mean 5.3 mm (B), 2.2 mm (A), 2.7 mm (U), 3.3 mm (R; p < 0.001). Posterior displacements predominated both at the base and the central region: mean 2.2 mm (B), 2.0 mm (U), 0.8 mm (A), -0.6 mm (R; p < 0.001). With a decreasing edema between day 1 and 30 (mean prostate volume of 51 cm{sup 3} vs. 41 cm{sup 3}; p < 0.001), a mean caudal prostate base displacement of 3.9 mm was found, whereas the mean inward displacement ranged from 1.2 to 1.6 mm at the remaining borders (lateral, anterior, posterior, apical). The analysis of the strand lengths revealed an implant compression between day 1 and 30 (mean 1.7 mm; p < 0.001). Conclusion: the largest prostate tissue and seed displacements were observed at the prostate base, associated with an implant compression. Predominantly inferior and posterior displacements implicate consequential smaller preplanning margins at the apex and the posterior prostate. (orig.)

  1. Validation of MRI to TRUS registration for high-dose-rate prostate brachytherapy.

    Science.gov (United States)

    Poulin, Eric; Boudam, Karim; Pinter, Csaba; Kadoury, Samuel; Lasso, Andras; Fichtinger, Gabor; Ménard, Cynthia

    The objective of this study was to develop and validate an open-source module for MRI to transrectal ultrasound (TRUS) registration to support tumor-targeted prostate brachytherapy. In this study, 15 patients with prostate cancer lesions visible on multiparametric MRI were selected for the validation. T2-weighted images with 1-mm isotropic voxel size and diffusion weighted images were acquired on a 1.5T Siemens imager. Three-dimensional (3D) TRUS images with 0.5-mm slice thickness were acquired. The investigated registration module was incorporated in the open-source 3D Slicer platform, which can compute rigid and deformable transformations. An extension of 3D Slicer, SlicerRT, allows import of and export to DICOM-RT formats. For validation, similarity indices, prostate volumes, and centroid positions were determined in addition to registration errors for common 3D points identified by an experienced radiation oncologist. The average time to compute the registration was 35 ± 3 s. For the rigid and deformable registration, respectively, Dice similarity coefficients were 0.87 ± 0.05 and 0.93 ± 0.01 while the 95% Hausdorff distances were 4.2 ± 1.0 and 2.2 ± 0.3 mm. MRI volumes obtained after the rigid and deformable registration were not statistically different (p > 0.05) from reference TRUS volumes. For the rigid and deformable registration, respectively, 3D distance errors between reference and registered centroid positions were 2.1 ± 1.0 and 0.4 ± 0.1 mm while registration errors between common points were 3.5 ± 3.2 and 2.3 ± 1.1 mm. Deformable registration was found significantly better (p < 0.05) than rigid registration for all parameters. An open-source MRI to TRUS registration platform was validated for integration in the brachytherapy workflow. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  2. Long-Term Outcome for Clinically Localized Prostate Cancer Treated With Permanent Interstitial Brachytherapy

    International Nuclear Information System (INIS)

    Taira, Al V.; Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Lief, Jonathan; Adamovich, Edward; Wallner, Kent E.

    2011-01-01

    Purpose: To present the largest series of prostate cancer brachytherapy patients treated with modern brachytherapy techniques and postimplant day 0 dosimetric evaluation. Methods and Materials: Between April 1995 and July 2006, 1,656 consecutive patients were treated with permanent interstitial brachytherapy. Risk group stratification was carried out according to the Mt. Sinai guidelines. Median follow-up was 7.0 years. The median day 0 minimum dose covering at least 90% of the target volume was 118.8% of the prescription dose. Cause of death was determined for each deceased patient. Multiple clinical, treatment, and dosimetric parameters were evaluated for impact on the evaluated survival parameters. Results: At 12 years, biochemical progression-free survival (bPFS), cause-specific survival (CSS), and overall survival (OS) for the entire cohort was 95.6%, 98.2%, and 72.6%, respectively. For low-, intermediate-, and high-risk patients, bPFS was 98.6%, 96.5%, and 90.5%; CSS was 99.8%, 99.3%, and 95.2%; and OS was 77.5%, 71.1%, and 69.2%, respectively. For biochemically controlled patients, the median posttreatment prostate-specific antigen (PSA) concentration was 0.02 ng/ml. bPFS was most closely related to percent positive biopsy specimens and risk group, while Gleason score was the strongest predictor of CSS. OS was best predicted by patient age, hypertension, diabetes, and tobacco use. At 12 years, biochemical failure and cause-specific mortality were 1.8% and 0.2%, 5.1% and 2.1%, and 10.4% and 7.1% for Gleason scores 5 to 6 and 7 and ≥8, respectively. Conclusions: Excellent long-term outcomes are achievable with high-quality brachytherapy for low-, intermediate-, and high-risk patients. These results compare favorably to alternative treatment modalities including radical prostatectomy.

  3. Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR Brachytherapy

    NARCIS (Netherlands)

    Gorissen, B.L.; den Hertog, D.; Hoffmann, A.L.

    2013-01-01

    Current inverse treatment planning methods that optimize both catheter positions and dwell times in prostate HDR brachytherapy use surrogate linear or quadratic objective functions that have no direct interpretation in terms of dose-volume histogram (DVH) criteria, do not result in an optimum or

  4. Optimum timing for image-based dose evaluation of 125I and 103Pd prostate seed implants

    International Nuclear Information System (INIS)

    Yue Ning; Chen Zhe; Peschel, Richard; Dicker, Adam P.; Waterman, Frank M.; Nath, Ravinder

    1999-01-01

    Purpose/Objective: Image-based dose evaluation of permanent brachytherapy implants for prostate cancer is important for optimal patient management after implantation. Because of edema caused by the surgical procedure in the implantation, if the dose evaluation is based on the images obtained too early after implantation, dose coverage will usually be underestimated. Conversely, if the images are obtained too late, the dose coverage will be overestimated. This study uses a biomathematical model to simulate edema and its resolution on 29 patients, so that the optimum time to obtain image scans and perform dose evaluation can be investigated and estimated. Methods and Materials: Edema of a prostate and its resolution has been shown to follow an exponential function V(t) = V(0)(1 + ΔV[e -0.693t/Te - 1]) where ΔV is the initial relative increase in the prostate volume due to edema (and is related to edema magnitude), and T e (edema half-life) is the time for the edema to decrease by half in volume. In this study, edema was simulated by increasing the volume of preimplant prostate (obtained from ultrasound volume study) to a given magnitude of edema. Similarly, the locations of planned seeds were changed to their corresponding locations in the edematous prostate proportionally. The edema was then allowed to resolve according to the exponential function. The correct dose distribution was calculated by taking into account the dynamic variations of the prostate volume, seed locations, and source strengths with respect to time. Dose volume histograms (DVHs) were then generated from this dose distribution. The conventional postimplant DVHs, which assume the prostate volume and seed locations are as in the image scans and constant in time, were also calculated based on the simulated image scans for various days postimplantation. The conventional DVHs of prostate on various days after implantation were compared to the DVH calculated assuming dynamic conditions. The optimum

  5. Evaluation of permanent I-125 prostate implants using radiographs and MRI

    International Nuclear Information System (INIS)

    Moerland, M.A.; Beersma, R.; Bhagwandien, R.; Wijrdeman, H.K.; Battermann, J.J.

    1995-01-01

    Introduction: Localized prostatic cancer is managed by radical prostatectomy, external beam irradiation or a permanent implant with I-125 seeds. Permanent implants are indicated for small tumours (T1-T2) with a well to moderate histological differentiation. The technique used is a transrectal ultrasound guided transperineal implantation technique, which aims for a seed and dose distribution such that the initial doserate line of 7.8 cGy/h encompasses the prostate resulting in an accumulated dose of 160 Gy. Up till now the seed and dose distribution is evaluated from isocentric radiographs, which do not show the relation with the prostate. Objectives: The aim of this study is the development of a technique to reconstruct and evaluate the seed and dose distribution within the prostate. Methods: Twenty patients underwent radiography on the simulator and scanning on a whole body NMR system within 3 days after implantation of the I-125 seeds. Isocentric radiographs were used for reconstruction of the seed distribution, after which registration with the MR images provided the seed positions in relation to the prostate. Volume dose histograms were used to evaluate the implants. Results: The I-125 seeds and the prostate anatomy were well depicted on T1-weighted spin echo images with minimal read out gradient strength. To date, ten implants were evaluated. According to our method, the prostate volumes receiving the prescribed dose of 160 Gy ranged from 30 to 70% of the total prostate volumes. Conclusion: The combination of isocentric radiographs and MRI enables reconstruction of the seed and dose distribution in relation to the prostate and the computation of dose volume histograms, which may be of value in the evaluation of implant quality

  6. {sup 125}I seed implant brachytherapy for the treatment of parotid gland cancers in children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, L.; Zhang, J.; Song, T.; Zhang, J.; Yu, G.; Zhang, Y. [Peking University School and Hospital of Stomatology, Beijing (China). Dept. of Oral and Maxillofacial Surgery

    2013-05-15

    Background and purpose: There is a lack of optimal treatment strategies for managing salivary gland cancers in children and adolescents. This study is aimed at assessing the effect of {sup 125}I seed implantation for the treatment of parotid cancers in children and adolescents. Patients and methods: A total of 12 patients younger than 16 years with parotid gland malignant tumors underwent {sup 125}I seed implant brachytherapy between October 2003 and November 2008. All patients were assessed after treatment and at the local tumor control appointments. Facial nerve function, maxillofacial development, and radioactive side-effects were assessed. Results: The follow-up period ranged from 41-104 months. One patient with T4b died of pulmonary metastasis. The other patients were alive during the follow-up period. There were no serious radiation-related complications. The treatment did not affect facial nerve function and dentofacial growth in any of the children. Conclusion: For parotid gland cancers in children, {sup 125}I seed implant brachytherapy may be an acceptable treatment without serious complications and with satisfactory short-term effects. (orig.)

  7. CT-guided {sup 125}I brachytherapy for mediastinal metastatic lymph nodes recurrence from esophageal carcinoma: Effectiveness and safety in 16 patients

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Fei, E-mail: gaof@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Li, Chuanxing, E-mail: licx@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Gu, Yangkui, E-mail: guyk@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Huang, Jinhua, E-mail: huangjh@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Wu, Peihong, E-mail: vivian-link@163.com [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China)

    2013-02-15

    Objectives: To retrospectively evaluate effectiveness and safety of CT-guided {sup 125}I brachytherapy in 16 patients with mediastinal metastatic lymph nodes recurrence from esophageal carcinoma. Materials and methods: Sixteen metastatic lymph nodes in 16 patients were percutaneously treated in 19 {sup 125}I brachytherapy sessions. Each metastatic lymph node was treated with computed tomographic (CT) guidance. Follow-up contrast material-enhanced CT or positron emission tomographic (PET) scans were reviewed and the treatment's effectiveness was evaluated. Results: Months are counted from the first time of {sup 125}I brachytherapy and the median duration of follow-up was 11 months (range, 5–16 months). The local control rates after 3, 6, 10 and 15 months were 75.0, 50.0, 42.9 and 33.3% respectively. At the time of writing, four patients are alive without evidence of recurrence at 16, 9, 16 and 9 months. The 4 patients presented good control of local tumor and no systemic recurrence, and survived throughout the follow-up period. The other 12 patients died of multiple hematogenous metastases 5–15 months after brachytherapy. A small amount of local hematoma occurred in 2 patients that involved applicator insertion through the lung. Two patients presented pneumothorax with pulmonary compression of 30 and 40% after the procedure and recovered after drainage. One patient had minor displacement of radioactive seeds. Severe complications such as massive bleeding and radiation pneumonitis did not occur. Conclusion: {sup 125}I radioactive seed implantation is effective and may be safely applied to mediastinal metastatic lymph nodes recurrence from esophageal carcinoma.

  8. Staff dose of hospitalization in the treatment of patients in ophthalmic brachytherapy with 125 I

    International Nuclear Information System (INIS)

    Terron Leon, J. A.; Gomez Palacios, M.; Moreno Reyes, J. C.; Perales Molina, A.

    2013-01-01

    The objective of this work, therefore, has been the evaluation of the dose levels which nursing staff can receive in care for ophthalmic brachytherapy patients treated with 125 I from measurements made on the same, evaluating, in an experimental way, job security following the PR rules laid down for these treatments. (Author)

  9. Comparison of Real-Time Intraoperative Ultrasound-Based Dosimetry With Postoperative Computed Tomography-Based Dosimetry for Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Shi Peipei; Liu Bingren; Gupta, Nilendu; Bahnson, Robert R.; Wang, Jian Z.

    2008-01-01

    Purpose: To evaluate whether real-time intraoperative ultrasound (US)-based dosimetry can replace conventional postoperative computed tomography (CT)-based dosimetry in prostate brachytherapy. Methods and Materials: Between December 2001 and November 2002, 82 patients underwent 103 Pd prostate brachytherapy. An interplant treatment planning system was used for real-time intraoperative transrectal US-guided treatment planning. The dose distribution was updated according to the estimated seed position to obtain the dose-volume histograms. Postoperative CT-based dosimetry was performed a few hours later using the Theraplan-Plus treatment planning system. The dosimetric parameters obtained from the two imaging modalities were compared. Results: The results of this study revealed correlations between the US- and CT-based dosimetry. However, large variations were found in the implant-quality parameters of the two modalities, including the doses covering 100%, 90%, and 80% of the prostate volume and prostate volumes covered by 100%, 150%, and 200% of the prescription dose. The mean relative difference was 38% and 16% for doses covering 100% and 90% of the prostate volume and 10% and 21% for prostate volumes covered by 100% and 150% of the prescription dose, respectively. The CT-based volume covered by 200% of the prescription dose was about 30% greater than the US-based one. Compared with CT-based dosimetry, US-based dosimetry significantly underestimated the dose to normal organs, especially for the rectum. The average US-based maximal dose and volume covered by 100% of the prescription dose for the rectum was 72 Gy and 0.01 cm 3 , respectively, much lower than the 159 Gy and 0.65 cm 3 obtained using CT-based dosimetry. Conclusion: Although dosimetry using intraoperative US-based planning provides preliminary real-time information, it does not accurately reflect the postoperative CT-based dosimetry. Until studies have determined whether US-based dosimetry or

  10. Intensity-Modulated Radiotherapy Causes Fewer Side Effects than Three-Dimensional Conformal Radiotherapy When Used in Combination With Brachytherapy for the Treatment of Prostate Cancer

    International Nuclear Information System (INIS)

    Forsythe, Kevin; Blacksburg, Seth; Stone, Nelson; Stock, Richard G.

    2012-01-01

    Purpose: To measure the benefits of intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3D-CRT) when used in combination with brachytherapy for the treatment of prostate cancer. Methods and Materials: We conducted a retrospective review of all patients with localized prostate cancer who received external-beam radiotherapy (EBRT) in combination with brachytherapy with at least 1 year follow-up (n = 812). Combination therapy consisted of 103 Pd or 125 I implant, followed by a course of EBRT. From 1993 to March 2003 521 patients were treated with 3D-CRT, and from April 2003 to March 2009 291 patients were treated with IMRT. Urinary symptoms were prospectively measured with the International Prostate Symptom Score questionnaire with a single quality of life (QOL) question; rectal bleeding was assessed per the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring Schema. The Pearson χ 2 test was used to compare toxicities experienced by patients who were treated with either IMRT or 3D-CRT. Logistic regression analyses were also performed to rule out possible confounding factors. Results: Within the first 3 months after treatment, patients treated with 3D-CRT scored their urinary symptoms as follows: 19% mild, 44% moderate, and 37% severe; patients treated with IMRT scored their urinary symptoms as follows: 36% mild, 47% moderate, and 17% severe (p < 0.001). The 3D-CRT patients rated their QOL as follows: 35% positive, 20% neutral, and 45% negative; IMRT patients rated their QOL as follows: 51% positive, 18% neutral, and 31% negative (p < 0.001). After 1 year of follow-up there was no longer any difference in urinary morbidity between the two groups. Logistic regression confirmed the differences in International Prostate Symptom Score and QOL in the acute setting (p < 0.001 for both). Grade ≥2 rectal bleeding was reported by 11% of 3D-CRT patients and 7

  11. Comparison of Oncentra® Brachy IPSA and graphical optimisation techniques: a case study of HDR brachytherapy head and neck and prostate plans

    International Nuclear Information System (INIS)

    Jameson, Michael G; Ohanessian, Lucy; Batumalai, Vikneswary; Patel, Virendra; Holloway, Lois C

    2015-01-01

    There are a number of different dwell positions and time optimisation options available in the Oncentra® Brachy (Elekta Brachytherapy Solutions, Veenendaal, The Netherlands) brachytherapy treatment planning system. The purpose of this case study was to compare graphical (GRO) and inverse planning by simulated annealing (IPSA) optimisation techniques for interstitial head and neck (HN) and prostate plans considering dosimetry, modelled radiobiology outcome and planning time. Four retrospective brachytherapy patients were chosen for this study, two recurrent HN and two prostatic boosts. Manual GRO and IPSA plans were generated for each patient. Plans were compared using dose–volume histograms (DVH) and dose coverage metrics including; conformity index (CI), homogeneity index (HI) and conformity number (CN). Logit and relative seriality models were used to calculate tumour control probability (TCP) and normal tissue complication probability (NTCP). Approximate planning time was also recorded. There was no significant difference between GRO and IPSA in terms of dose metrics with mean CI of 1.30 and 1.57 (P > 0.05) respectively. IPSA achieved an average HN TCP of 0.32 versus 0.12 for GRO while for prostate there was no significant difference. Mean GRO planning times were greater than 75 min while average IPSA planning times were less than 10 min. Planning times for IPSA were greatly reduced compared to GRO and plans were dosimetrically similar. For this reason, IPSA makes for a useful planning tool in HN and prostate brachytherapy

  12. High-dose-rate brachytherapy as salvage modality for locally recurrent prostate cancer after definitive radiotherapy. A systematic review

    International Nuclear Information System (INIS)

    Chatzikonstantinou, Georgios; Zamboglou, Nikolaos; Roedel, Claus; Tselis, Nikolaos; Zoga, Eleni; Strouthos, Iosif; Butt, Saeed Ahmed

    2017-01-01

    To review the current status of interstitial high-dose-rate brachytherapy as a salvage modality (sHDR BRT) for locally recurrent prostate cancer after definitive radiotherapy (RT). A literature search was performed in PubMed using ''high-dose-rate, brachytherapy, prostate cancer, salvage'' as search terms. In all, 51 search results published between 2000 and 2016 were identified. Data tables were generated and summary descriptions created. The main outcome parameters used were biochemical control (BC) and toxicity scores. Eleven publications reported clinical outcome and toxicity with follow-up ranging from 4-191 months. A variety of dose and fractionation schedules were described, including 19.0 Gy in 2 fractions up to 42.0 Gy in 6 fractions. The 5-year BC ranged from 18-77%. Late grade 3 genitourinary and gastrointestinal toxicity was 0-32% and 0-5.1%, respectively. sHDR BRT appears as safe and effective salvage modality for the reirradiation of locally recurrent prostate cancer after definitive RT. (orig.) [de

  13. Prostate brachytherapy

    Science.gov (United States)

    Implant therapy - prostate cancer; Radioactive seed placement; Internal radiation therapy - prostate; High dose radiation (HDR) ... place the seeds that deliver radiation into your prostate. The seeds are placed with needles or special ...

  14. Detection and correction of patient movement in prostate brachytherapy seed reconstruction

    Science.gov (United States)

    Lam, Steve T.; Cho, Paul S.; Marks, Robert J., II; Narayanan, Sreeram

    2005-05-01

    Intraoperative dosimetry of prostate brachytherapy can help optimize the dose distribution and potentially improve clinical outcome. Evaluation of dose distribution during the seed implant procedure requires the knowledge of 3D seed coordinates. Fluoroscopy-based seed localization is a viable option. From three x-ray projections obtained at different gantry angles, 3D seed positions can be determined. However, when local anaesthesia is used for prostate brachytherapy, the patient movement during fluoroscopy image capture becomes a practical problem. If uncorrected, the errors introduced by patient motion between image captures would cause seed mismatches. Subsequently, the seed reconstruction algorithm would either fail to reconstruct or yield erroneous results. We have developed an algorithm that permits detection and correction of patient movement that may occur between fluoroscopy image captures. The patient movement is decomposed into translational shifts along the tabletop and rotation about an axis perpendicular to the tabletop. The property of spatial invariance of the co-planar imaging geometry is used for lateral movement correction. Cranio-caudal movement is corrected by analysing the perspective invariance along the x-ray axis. Rotation is estimated by an iterative method. The method can detect and correct for the range of patient movement commonly seen in the clinical environment. The algorithm has been implemented for routine clinical use as the preprocessing step for seed reconstruction.

  15. Prostate preservation by combined external beam and hdr brachytherapy at nodal negative prostate cancer patients - an intermediate analysis after ten years experience

    International Nuclear Information System (INIS)

    Kovacs, G.; Wirth, B.; Bertermann, H.; Galalae, R.; Kohr, P.; Wilhelm, R.; Kimmig, B.

    1996-01-01

    prostate cancer, 18 of intercurrent disease. Clinical progression in 21 cases (14 systemic, 5 local, 2 both syst.+ local). Average interval between therapy and progression was 27 months with a median of 21 months. All cases of clinical progression with PSA elevation. Average period between PSA nadir and clinical progression was 21 months (14 months for systemic; 34 months for local progression). All patients, whose PSA did not decrease under 1 ng/ml developed progression (p<0.001). Progression developed in 11% of the 112 organ-confined (T1-2/A2-B) and 9 (15%) of the 59 unconfined tumors (T3 / C). The relation between tumor grading and total progression (clinical + PSA) was as follows: five out of 27 G1 tumors, 9 out of 86 G2 tumors and 23 of the 58 G3/4 tumors developed a progression. Side effects: 12 grade I (RTOG/EORTC), 10 grade II and 5 grade III proctitis (One out of 5 needed abdominal anus), as well as 13 grade I, 14 grade II and 3 grade III dysuria/cystitis. Incontinence (9 patients) occurred only in previously transurethral resected cases. One osteoporotic patient had an osseous radionecrosis of both pubic rami. Conclusion: The results of this intermediate analysis suggest, that the described method seems to be superior to conventional external beam schedules in the case of local advanced (T3 / C) and it is clearly superior to Iodine-125 brachytherapy methods. In the follow-up PSA turns out as the most important prognostic factor. Transrectal sonography is another essential tool for detection of local progression

  16. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mashouf, S; Merino, T; Ravi, A; Morton, G; Song, W [Sunnybrook Health Sciences Center, Odette Cancer Centre, Toronto, ON (Canada); University of Toronto, Dept. of Radiation Oncology, Toronto, ON (Canada); Safigholi, H; Soliman, A [Sunnybrook Research Institute, Toronto, ON (Canada)

    2016-06-15

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

  17. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    International Nuclear Information System (INIS)

    Mashouf, S; Merino, T; Ravi, A; Morton, G; Song, W; Safigholi, H; Soliman, A

    2016-01-01

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

  18. High-Dose-Rate Brachytherapy as a Monotherapy for Favorable-Risk Prostate Cancer: A Phase II Trial

    International Nuclear Information System (INIS)

    Barkati, Maroie; Williams, Scott G.; Foroudi, Farshad; Tai, Keen Hun; Chander, Sarat; Dyk, Sylvia van; See, Andrew; Duchesne, Gillian M.

    2012-01-01

    Purpose: There are multiple treatment options for favorable-risk prostate cancer. High-dose-rate (HDR) brachytherapy as a monotherapy is appealing, but its use is still investigational. A Phase II trial was undertaken to explore the value of such treatment in low-to-intermediate risk prostate cancer. Methods and Materials: This was a single-institution, prospective study. Eligible patients had low-risk prostate cancer features but also Gleason scores of 7 (51% of patients) and stage T2b to T2c cancer. Treatment with HDR brachytherapy with a single implant was administered over 2 days. One of four fractionation schedules was used in a dose escalation study design: 3 fractions of 10, 10.5, 11, or 11.5 Gy. Patients were assessed with the Common Terminology Criteria for Adverse Events version 2.0 for urinary toxicity, the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scoring schema for rectal toxicity, and the Expanded Prostate Cancer Index Composite (EPIC) questionnaire to measure patient-reported health-related quality of life. Biochemical failure was defined as a prostate-specific antigen (PSA) nadir plus 2 ng/ml. Results: Between 2003 and 2008, 79 patients were enrolled. With a median follow-up of 39.5 months, biochemical relapse occurred in 7 patients. Three- and 5-year actuarial biochemical control rates were 88.4% (95% confidence interval [CI], 78.0-96.2%) and 85.1% (95% CI, 72.5-94.5%), respectively. Acute grade 3 urinary toxicity was seen in only 1 patient. There was no instance of acute grade 3 rectal toxicity. Rates of late grade 3 rectal toxicity, dysuria, hematuria, urinary retention, and urinary incontinence were 0%, 10.3%, 1.3%, 9.0%, and 0%, respectively. No grade 4 or greater toxicity was recorded. Among the four (urinary, bowel, sexual, and hormonal) domains assessed with the EPIC questionnaire, only the sexual domain did not recover with time. Conclusions: HDR brachytherapy as a monotherapy for favorable

  19. High-Dose-Rate Brachytherapy as a Monotherapy for Favorable-Risk Prostate Cancer: A Phase II Trial

    Energy Technology Data Exchange (ETDEWEB)

    Barkati, Maroie [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Williams, Scott G., E-mail: scott.williams@petermac.org [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Pathology, University of Melbourne, Melbourne (Australia); Foroudi, Farshad; Tai, Keen Hun; Chander, Sarat [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Pathology, University of Melbourne, Melbourne (Australia); Dyk, Sylvia van [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); See, Andrew [Ballarat Austin Radiation Oncology Centre, Ballarat (Australia); Duchesne, Gillian M. [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Pathology, University of Melbourne, Melbourne (Australia)

    2012-04-01

    Purpose: There are multiple treatment options for favorable-risk prostate cancer. High-dose-rate (HDR) brachytherapy as a monotherapy is appealing, but its use is still investigational. A Phase II trial was undertaken to explore the value of such treatment in low-to-intermediate risk prostate cancer. Methods and Materials: This was a single-institution, prospective study. Eligible patients had low-risk prostate cancer features but also Gleason scores of 7 (51% of patients) and stage T2b to T2c cancer. Treatment with HDR brachytherapy with a single implant was administered over 2 days. One of four fractionation schedules was used in a dose escalation study design: 3 fractions of 10, 10.5, 11, or 11.5 Gy. Patients were assessed with the Common Terminology Criteria for Adverse Events version 2.0 for urinary toxicity, the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scoring schema for rectal toxicity, and the Expanded Prostate Cancer Index Composite (EPIC) questionnaire to measure patient-reported health-related quality of life. Biochemical failure was defined as a prostate-specific antigen (PSA) nadir plus 2 ng/ml. Results: Between 2003 and 2008, 79 patients were enrolled. With a median follow-up of 39.5 months, biochemical relapse occurred in 7 patients. Three- and 5-year actuarial biochemical control rates were 88.4% (95% confidence interval [CI], 78.0-96.2%) and 85.1% (95% CI, 72.5-94.5%), respectively. Acute grade 3 urinary toxicity was seen in only 1 patient. There was no instance of acute grade 3 rectal toxicity. Rates of late grade 3 rectal toxicity, dysuria, hematuria, urinary retention, and urinary incontinence were 0%, 10.3%, 1.3%, 9.0%, and 0%, respectively. No grade 4 or greater toxicity was recorded. Among the four (urinary, bowel, sexual, and hormonal) domains assessed with the EPIC questionnaire, only the sexual domain did not recover with time. Conclusions: HDR brachytherapy as a monotherapy for favorable

  20. Incidence of Secondary Cancer Development After High-Dose Intensity-Modulated Radiotherapy and Image-Guided Brachytherapy for the Treatment of Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Housman, Douglas M.; Pei Xin; Alicikus, Zumre; Magsanoc, Juan Martin; Dauer, Lawrence T.; St Germain, Jean; Yamada, Yoshiya; Kollmeier, Marisa; Cox, Brett; Zhang Zhigang

    2012-01-01

    Purpose: To report the incidence and excess risk of second malignancy (SM) development compared with the general population after external beam radiotherapy (EBRT) and brachytherapy to treat prostate cancer. Methods and Materials: Between 1998 and 2001, 1,310 patients with localized prostate cancer were treated with EBRT (n = 897) or brachytherapy (n = 413). We compared the incidence of SMs in our patients with that of the general population extracted from the National Cancer Institute’s Surveillance, Epidemiology, and End Results data set combined with the 2000 census data. Results: The 10-year likelihood of SM development was 25% after EBRT and 15% after brachytherapy (p = .02). The corresponding 10-year likelihood for in-field SM development in these groups was 4.9% and 1.6% (p = .24). Multivariate analysis showed that EBRT vs. brachytherapy and older age were the only significant predictors for the development of all SMs (p = .037 and p = .030), with a trend for older patients to develop a SM. The increased incidence of SM for EBRT patients was explained by the greater incidence of skin cancer outside the radiation field compared with that after brachytherapy (10.6% and 3.3%, respectively, p = .004). For the EBRT group, the 5- and 10-year mortality rate was 1.96% and 5.1% from out-of field cancer, respectively; for in-field SM, the corresponding mortality rates were 0.1% and 0.7%. Among the brachytherapy group, the 5- and 10-year mortality rate related to out-of field SM was 0.8% and 2.7%, respectively. Our observed SM rates after prostate RT were not significantly different from the cancer incidence rates in the general population. Conclusions: Using modern sophisticated treatment techniques, we report low rates of in-field bladder and rectal SM risks after prostate cancer RT. Furthermore, the likelihood of mortality secondary to a SM was unusual. The greater rate of SM observed with EBRT vs. brachytherapy was related to a small, but significantly increased

  1. Sexual potency following interactive ultrasound-guided brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Stock, Richard G.; Stone, Nelson N.; Iannuzzi, Christopher

    1996-01-01

    Purpose: The effect of a therapeutic modality on sexual potency is often an important consideration for patients choosing a treatment for prostate cancer. We prospectively assessed patients' penile erectile function before and following interactive ultrasound-guided transperineal permanent radioactive seed implantation to determine its effect on sexual function. Methods and Materials: Eighty-nine patients underwent permanent radioactive seed implantation from June 1990 to April 1994 for localized prostate cancer (T1-T2) and were followed for a median of 15 months (1.5-52 months). 125 I seeds were implanted in 73 patients with a combined Gleason grade of 2-6, and 103 Pd seeds were implanted in 16 patients with higher grade lesions. The sexual potency of these patients was assessed prior to, at 3 and 6 months, and every 6 months after implantation. Erectile function was graded using a numerical score of 0 to 3 (0 = impotent (no erections), 1 = ability to have erections but insufficient for vaginal penetration, 2 = erectile function sufficient for vaginal penetration but suboptimal, 3 = normal erectile function). The pretreatment potency scores were as follows: 0 in 24 patients, 1 in 6 patients, 2 in 22 patients, and 3 in 37 patients. Results: The actuarial impotency rates (score = 0) following implantation for those patients possessing some degree of erectile function prior to implantation (65 patients) were 2.5% at 1 year and 6% at 2 years. The actuarial decrease in sexual function rates (a drop in score of at least one point) were 29% at 1 year and 39% at 2 years. Only two patients became impotent following treatment and this occurred at 1 year and 16 months. The time period for a decrease in erectile function to occur ranged from 1.8 months to 32.7 months, with a median of 6.8 months. Patients with higher grade tumors showed a greater decrease in potency score compared to patients with lower grade tumors. Conclusion: Interactive ultrasound-guided transperineal

  2. Cost comparison of curative therapies for localized prostate cancer in Japan. A single-institution experience

    International Nuclear Information System (INIS)

    Satoh, Takefumi; Ishiyama, Hiromichi; Matsumoto, Kazumasa

    2009-01-01

    In addition to open surgery, curative therapies for prostate cancer now include endoscopic surgery and radiation therapies. Because of the expansion and subdivision of treatment methods for prostate cancer, the medical fee point schedule in Japan was revised in fiscal year 2006. We examined changes in medical income and expenditure after this revision of the medical fee system. We studied income and expenditure, after institution of the new medical fee schedule, for the five types of therapies for prostate cancer performed at our hospital: two surgical therapies (radical retropubic prostatectomy and laparoscopic prostatectomy) and three radiation therapies (three-dimensional conformal radiation therapy, 192 Ir high-dose-rate brachytherapy, and 125 I low-dose-rate brachytherapy). Low-dose-rate brachytherapy was found to be associated with a profit of 199 yen per patient. Laparoscopic prostatectomy, a highly advanced medical treatment that the fee revision changed from a partially insured to an insured procedure, yielded a profit of 75672 yen per patient. However, high-dose-rate brachytherapy was associated with a loss of 654016 yen per patient. Given the loss in hospital income per patient undergoing high-dose-rate brachytherapy, the medical fee point system for this procedure should be reassessed. (author)

  3. Radiation proctitis after the high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Kitano, Masashi; Katsumata, Tomoe; Satoh, Takefumi

    2006-01-01

    We reviewed the medical records of 12 patients treated for rectal bleeding after high-dose rate brachytherapy for prostate cancer. All patients developed grade 2 proctitis according to the Common Terminology Criteria for Adverse Events (CTCAC) and no patients needed blood transfusion. The patients were treated with argon plasma coagulation (APC) and/or steroid suppositories. The bleeding stopped or improved in 11 patients. Although re-bleeding was noticed in 7 patients the same treatment was effective in 5 patients. (author)

  4. Favorable Preliminary Outcomes for Men With Low- and Intermediate-risk Prostate Cancer Treated With 19-Gy Single-fraction High-dose-rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Daniel J., E-mail: dkrauss@beaumont.edu [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Ye, Hong [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Martinez, Alvaro A. [21st Century Oncology, Farmington Hills, Michigan (United States); Mitchell, Beth; Sebastian, Evelyn; Limbacher, Amy; Gustafson, Gary S. [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States)

    2017-01-01

    Purpose: To report the toxicity and preliminary clinical outcomes of a prospective trial evaluating 19-Gy, single-fraction high-dose-rate (HDR) brachytherapy for men with low- and intermediate-risk prostate cancer. Methods and Materials: A total of 63 patients were treated according to an institutional review board-approved prospective study of single-fraction HDR brachytherapy. Eligible patients had tumor stage ≤T2a, prostate-specific antigen level ≤15 ng/mL, and Gleason score ≤7. Patients with a prostate gland volume >50 cm{sup 3} and baseline American Urologic Association symptom score >12 were ineligible. Patients underwent transrectal ultrasound-guided transperineal implantation of the prostate, followed by single-fraction HDR brachytherapy. Treatment was delivered using {sup 192}Ir to a dose of 19 Gy prescribed to the prostate, with no additional margin applied. Results: Of the 63 patients, 58 had data available for analysis. Five patients had withdrawn consent during the follow-up period. The median follow-up period was 2.9 years (range 0.3-5.2). The median age was 61.4 years. The median gland volume at treatment was 34.8 cm{sup 3}. Of the 58 patients, 91% had T1 disease, 71% had Gleason score ≤6 (29% with Gleason score 7), and the median pretreatment prostate-specific antigen level was 5.1 ng/mL. The acute and chronic grade 2 genitourinary toxicity incidence was 12.1% and 10.3%, respectively. No grade 3 urinary toxicity occurred. No patients experienced acute rectal toxicity grade ≥2, and 2 experienced grade ≥2 chronic gastrointestinal toxicity. Three patients experienced biochemical failure, yielding a 3-year cumulative incidence estimate of 6.8%. Conclusions: Single-fraction HDR brachytherapy is well-tolerated, with favorable preliminary biochemical and clinical disease control rates.

  5. Long-Term Outcome and Toxicity of Salvage Brachytherapy for Local Failure After Initial Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Burri, Ryan J.; Stone, Nelson N.; Unger, Pam; Stock, Richard G.

    2010-01-01

    Purpose: To describe long-term outcomes and toxicity after salvage brachytherapy (BT) for local failure after initial radiotherapy for prostate cancer. Methods and Materials: Between 1994 and 2008, 37 men with local failure after initial prostate radiotherapy (32 external-beam radiation therapy [EBRT] and 5 BT) underwent salvage BT with 103 Pd or 125 I. Estimates of freedom from biochemical failure (FFbF, Phoenix definition) and cause-specific survival (CSS) were calculated using the Kaplan-Meier method. Toxicities were graded using CTCv3.0. Results: Median follow-up was 86 months (range, 2-156). The median dose to 90% of the prostate volume was 122 Gy (range, 67-166). The 10-year FFbF and CSS were 54% and 96%, respectively. On univariate analysis, prostate-specific antigen (PSA) >10 ng/mL at initial diagnosis was significantly associated with FFbF (p = 0.01), and there were trends for both age <70 years (p = 0.08) and PSA <6 ng/mL (p = 0.08) at the time of salvage BT. On multivariate analysis, only presalvage PSA <6 ng/mL (p = 0.046) was significantly associated with improved FFbF. There were three Grade 3 toxicities and one Grade 4 toxicity. Pelvic lymph node dissection before salvage BT was the only variable significantly associated with Grade ≥2 toxicity (p = 0.03). Conclusion: With a median follow-up of 86 months, salvage prostate BT was associated with a 10-year FFbF of 54% and CSS of 96%. Improved FFbF was associated with a presalvage PSA <6 ng/mL. Toxicity was worse in patients who had undergone pelvic lymph node dissection before salvage BT. Careful patient selection for salvage BT may result in improved outcomes and reduced toxicity.

  6. The Quadrella: A novel approach to analyzing optimal outcomes after permanent seed prostate brachytherapy

    International Nuclear Information System (INIS)

    Tétreault-Laflamme, Audrey; Zilli, Thomas; Meissner, Aliza; Larrivée, Sandra; Sylvestre, Marie-Pierre; Delouya, Guila

    2014-01-01

    Background and purpose: To study a four-point combined analysis (Quadrella) of optimal outcome among patients treated with exclusive permanent seed prostate brachytherapy (PB), as defined by the likelihood of achieving disease control and preserving normal urinary, gastro-intestinal (GI) and sexual function. Materials and methods: 384 patients with localized prostate cancer underwent PB at our institution with 125 I at a dose level of 144 Gy. Subjects with erectile dysfunction who did not respond to medication were excluded. 281 patients with minimum 3-year follow-up were evaluated. Patients with concurrent biochemical progression-free survival (bPFS), absent urinary and GI toxicities (grade 0 toxicities according to CTCAE v 3.0) and preserved sexual potency (with our without medication) were classified as the Quadrella group. Results: Among the 281 patients analyzed, the Quadrella was achieved in 49.1%, 48.0%, 50.4%, 41.7% and 65.2% in years 3–7, respectively. bPFS rates were 82.6–96.1%, corresponding potency rates were 63.6–82.3%, and normal urinary and GI function rates were 64.8–82.6% and 95–100%, respectively. By multivariate analysis, significant predictors of Quadrella were age (p = 0.015), baseline IPSS (p = 0.03) and time since PB (p = 0.02). Conclusion: Urinary and sexual toxicity remained the most common reasons for excluding patients from a perfect outcome (Quadrella), defined by strict criteria. This analysis can be useful for subsequent comparison between treatment modalities

  7. 103PD brachytherapy and external beam irradiation for clinically localized, high-risk prostatic carcinoma

    International Nuclear Information System (INIS)

    Dattoli, Michael; Wallner, Kent; Sorace, Richard; Koval, John; Cash, Jennifer; Acosta, Rudolph; Brown, Charles; Etheridge, James; Binder, Michael; Brunelle, Richard; Kirwan, Novelle; Sanchez, Servando; Stein, Douglas; Wasserman, Stuart

    1996-01-01

    Purpose: To summarize biochemical failure rates and morbidity of external beam irradiation (EBRT) combined with palladium ( 103 Pd) boost for clinically localized high-risk prostate carcinoma. Methods and Materials: Seventy-three consecutive patients with stage T2a-T3 prostatic carcinoma were treated from 1991 through 1994. Each patient had at least one of the following risk factors for extracapsular disease extension: Stage T2b or greater (71 patients), Gleason score 7-10 (40 patients), prostate specific antigen (PSA) >15 (32 patients), or elevated prostatic acid phosphatase (PAP) (17 patients). Patients received 41 Gy EBRT to a limited pelvic field, followed 4 weeks later by a 103 Pd boost (prescription dose: 80 Gy). Biochemical failure was defined as a PSA greater than 1.0 ng/ml (normal 103 Pd brachytherapy for clinically localized, high-risk prostate cancer compare favorably with that reported after conventional dose EBRT alone. Morbidity has been acceptable

  8. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications

    Science.gov (United States)

    Lemaréchal, Yannick; Bert, Julien; Falconnet, Claire; Després, Philippe; Valeri, Antoine; Schick, Ulrike; Pradier, Olivier; Garcia, Marie-Paule; Boussion, Nicolas; Visvikis, Dimitris

    2015-07-01

    In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding to be routinely used. In this work we implemented and evaluated an accurate and fast MCS on Graphics Processing Units (GPU) for brachytherapy low dose rate (LDR) applications. A previously proposed Geant4 based MCS framework implemented on GPU (GGEMS) was extended to include a hybrid GPU navigator, allowing navigation within voxelized patient specific images and analytically modeled 125I seeds used in LDR brachytherapy. In addition, dose scoring based on track length estimator including uncertainty calculations was incorporated. The implemented GGEMS-brachy platform was validated using a comparison with Geant4 simulations and reference datasets. Finally, a comparative dosimetry study based on the current clinical standard (TG43) and the proposed platform was performed on twelve prostate cancer patients undergoing LDR brachytherapy. Considering patient 3D CT volumes of 400  × 250  × 65 voxels and an average of 58 implanted seeds, the mean patient dosimetry study run time for a 2% dose uncertainty was 9.35 s (≈500 ms 10-6 simulated particles) and 2.5 s when using one and four GPUs, respectively. The performance of the proposed GGEMS-brachy platform allows envisaging the use of Monte Carlo simulation based dosimetry studies in brachytherapy compatible with clinical practice. Although the proposed platform was evaluated for prostate cancer, it is equally applicable to other LDR brachytherapy clinical applications. Future extensions will allow its application in high dose rate brachytherapy applications.

  9. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications

    International Nuclear Information System (INIS)

    Lemaréchal, Yannick; Bert, Julien; Schick, Ulrike; Pradier, Olivier; Garcia, Marie-Paule; Boussion, Nicolas; Visvikis, Dimitris; Falconnet, Claire; Després, Philippe; Valeri, Antoine

    2015-01-01

    In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding to be routinely used. In this work we implemented and evaluated an accurate and fast MCS on Graphics Processing Units (GPU) for brachytherapy low dose rate (LDR) applications. A previously proposed Geant4 based MCS framework implemented on GPU (GGEMS) was extended to include a hybrid GPU navigator, allowing navigation within voxelized patient specific images and analytically modeled 125 I seeds used in LDR brachytherapy. In addition, dose scoring based on track length estimator including uncertainty calculations was incorporated. The implemented GGEMS-brachy platform was validated using a comparison with Geant4 simulations and reference datasets. Finally, a comparative dosimetry study based on the current clinical standard (TG43) and the proposed platform was performed on twelve prostate cancer patients undergoing LDR brachytherapy. Considering patient 3D CT volumes of 400  × 250  × 65 voxels and an average of 58 implanted seeds, the mean patient dosimetry study run time for a 2% dose uncertainty was 9.35 s (≈500 ms 10 −6 simulated particles) and 2.5 s when using one and four GPUs, respectively. The performance of the proposed GGEMS-brachy platform allows envisaging the use of Monte Carlo simulation based dosimetry studies in brachytherapy compatible with clinical practice. Although the proposed platform was evaluated for prostate cancer, it is equally applicable to other LDR brachytherapy clinical applications. Future extensions will allow its application in high dose rate brachytherapy applications. (paper)

  10. Quantification of iodine in porous hydroxyapatite matrices for application as radioactive sources in brachytherapy

    Directory of Open Access Journals (Sweden)

    Kássio André Lacerda

    2007-07-01

    Full Text Available In this study, non-radioactive iodine was incorporated in two types of biodegradable hydroxyapatite-based porous matrices (HA and HACL through impregnation process from sodium iodine aqueous solutions with varying concentrations (0.5 and 1.0 mol/L . The results revealed that both systems presented a high capacity of incorporating iodine into their matrices. The quantity of incorporated iodine was measured through Neutron Activation Analysis (NAA. The porous ceramic matrices based on hydroxyapatite demonstrated a great potential for uses in low dose rate (LDR brachytherapy.Materiais cerâmicos porosos à base de compostos de fosfatos de cálcio (CFC vêm sendo estudados e desenvolvidos para várias aplicações biomédicas tais como implantes, sistemas para liberação de drogas e fontes radioativas para braquiterapia. Dois tipos de matrizes porosas biodegradáveis de hidroxiapatita (HA e HACL foram avaliadas em termos da capacidade de incorporação de iodo em suas estruturas. Resultados revelaram que as matrizes porosas a base de hidroxiapatita apresentaram alta capacidade de incorporar iodo em sua estrutura. A quantidade de iodo foi mensurada através da técnica de Análise por Ativação Nêutronica (AAN. As matrizes cerâmicas porosas à base de hidroxiapatita demostraram ter grande potencial para aplicação em braquiterapia de baixa taxa de dose (LDR - Low Dose Rate.

  11. High-dose-rate brachytherapy as salvage modality for locally recurrent prostate cancer after definitive radiotherapy. A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Chatzikonstantinou, Georgios; Zamboglou, Nikolaos; Roedel, Claus; Tselis, Nikolaos [J.W. Goethe University of Frankfurt, Department of Radiotherapy and Oncology, Frankfurt am Main (Germany); Zoga, Eleni [Sana Klinikum Offenbach, Department of Radiotherapy and Oncology, Offenbach am Main (Germany); Strouthos, Iosif [Medical Center - University of Freiburg, Department of Radiotherapy and Oncology, University of Freiburg, Freiburg (Germany); Butt, Saeed Ahmed [Sana Klinikum Offenbach, Department of Medical Physics and Engineering, Offenbach am Main (Germany)

    2017-09-15

    To review the current status of interstitial high-dose-rate brachytherapy as a salvage modality (sHDR BRT) for locally recurrent prostate cancer after definitive radiotherapy (RT). A literature search was performed in PubMed using ''high-dose-rate, brachytherapy, prostate cancer, salvage'' as search terms. In all, 51 search results published between 2000 and 2016 were identified. Data tables were generated and summary descriptions created. The main outcome parameters used were biochemical control (BC) and toxicity scores. Eleven publications reported clinical outcome and toxicity with follow-up ranging from 4-191 months. A variety of dose and fractionation schedules were described, including 19.0 Gy in 2 fractions up to 42.0 Gy in 6 fractions. The 5-year BC ranged from 18-77%. Late grade 3 genitourinary and gastrointestinal toxicity was 0-32% and 0-5.1%, respectively. sHDR BRT appears as safe and effective salvage modality for the reirradiation of locally recurrent prostate cancer after definitive RT. (orig.) [German] Zusammenfassende Darstellung relevanter Literatur zur interstitiellen High-Dose-Rate-Brachytherapie als Salvage-Modalitaet (sHDR-BRT) bei der Behandlung des lokal rezidivierten Prostatakarzinoms nach vorausgegangener definitiver Radiotherapie (RT). In der PubMed-Datenbank wurde eine Literaturrecherche mit den Suchbegriffen ''high-dose-rate, brachytherapy, prostate cancer, salvage'' durchgefuehrt. Zwischen den Jahren 2000 und 2016 wurden 51 Publikationen identifiziert. Die biochemische Kontrolle (BC) sowie das assoziierte Toxizitaetsprofil waren onkologische Hauptpunkte in der Analyse der beruecksichtigten Literatur. Von onkologischen Ergebnissen und Toxizitaeten berichteten 11 Publikationen bei einer medianen Nachbeobachtungszeit von 4-191 Monaten. Eine Variabilitaet von Dosis- und Fraktionierungsregimen wurde beschrieben mit totalen physikalischen Dosen von 19,0 Gy in 2 Fraktionen bis zu 42,0 Gy in 6 Fraktionen

  12. Iodine-125 Chitosan-Vitamin C complex. Preparation, characterization and application

    Energy Technology Data Exchange (ETDEWEB)

    Elbarbary, Ahmed M. [National Center for Radiation Research and Technology, Cairo (Egypt). Polymer Chemistry Dept.; Shafik, H.M.; Ebeid, N.H.; Ayoub, S.M. [Atomic Energy Authority, Cairo (Egypt). Hot Lab. Center; Othman, Sameh H. [Atomic Energy Authority, Cairo (Egypt). Nuclear Research Center

    2015-07-01

    In heterogeneous conditions, water soluble Chitosan-Vitamin C Complex (CSVC) is successfully synthesized via the ionic interaction between γ-degraded CS and VC. Chitosan (CS) of low molecular weight (MW) is prepared using γ-irradiation method. The coupling of CS and vitamin C (VC) is carried out by the chemical treatment of VC with the γ-degraded CS. The formation of CSVC complex instead of physical mixture is confirmed by FT-IR and UV spectrometry. Characterization by transmission electron microscope (TEM) and dynamic light scattering (DLS) shows the formation of a nanostructure in 40 nm range. The preparation of labeled CSVC was performed using chloramines-T oxidation method. The labeling feasibility of CSVC nanostructure by Iodine-125 ({sup 125}I) is investigated. The optimized conditions of labeling are thought to be 50 μg of oxidizing agent, pH 3, and one minute reaction time. The Biodistribution activity of {sup 125}I radiolabeled CSVC nanostructure ({sup 125}I-CSVC) is examined on a group of different ascites tumor bearing mice. Calculation of the biodistribution percentages shows that the tumor, liver, and kidney are the targeting organs of {sup 125}I-CSVC nanostructure.

  13. Iodine-125 Chitosan-Vitamin C complex. Preparation, characterization and application

    International Nuclear Information System (INIS)

    Elbarbary, Ahmed M.; Shafik, H.M.; Ebeid, N.H.; Ayoub, S.M.; Othman, Sameh H.

    2015-01-01

    In heterogeneous conditions, water soluble Chitosan-Vitamin C Complex (CSVC) is successfully synthesized via the ionic interaction between γ-degraded CS and VC. Chitosan (CS) of low molecular weight (MW) is prepared using γ-irradiation method. The coupling of CS and vitamin C (VC) is carried out by the chemical treatment of VC with the γ-degraded CS. The formation of CSVC complex instead of physical mixture is confirmed by FT-IR and UV spectrometry. Characterization by transmission electron microscope (TEM) and dynamic light scattering (DLS) shows the formation of a nanostructure in 40 nm range. The preparation of labeled CSVC was performed using chloramines-T oxidation method. The labeling feasibility of CSVC nanostructure by Iodine-125 ( 125 I) is investigated. The optimized conditions of labeling are thought to be 50 μg of oxidizing agent, pH 3, and one minute reaction time. The Biodistribution activity of 125 I radiolabeled CSVC nanostructure ( 125 I-CSVC) is examined on a group of different ascites tumor bearing mice. Calculation of the biodistribution percentages shows that the tumor, liver, and kidney are the targeting organs of 125 I-CSVC nanostructure.

  14. An Eight-Year Experience of HDR Brachytherapy Boost for Localized Prostate Cancer: Biopsy and PSA Outcome

    International Nuclear Information System (INIS)

    Bachand, Francois; Martin, Andre-Guy; Beaulieu, Luc; Harel, Francois M.Sc.; Vigneault, Eric

    2009-01-01

    Purpose: To evaluate the biochemical recurrence-free survival (bRFS), the 2-year biopsy outcome and the prostate-specific antigen (PSA) bounce in patients with localized prostate cancer treated with an inversely planned high-dose-rate (HDR) brachytherapy boost. Materials and methods: Data were collected from 153 patients treated between 1999 and 2006 with external beam pelvic radiation followed by an HDR Ir-192 prostate boost. These patients were given a boost of 18 to 20 Gy using inverse-planning with simulated annealing (IPSA).We reviewed and analyzed all prostate-specific antigen levels and control biopsies. Results: The median follow-up was 44 months (18-95 months). When categorized by risk of progression, 74.5% of patients presented an intermediate risk and 14.4% a high one. Prostate biopsies at 2 years posttreatment were negative in 86 of 94 patients (91.5%), whereas two biopsies were inconclusive. Biochemical control at 60 months was at 96% according to the American Society for Therapeutic Radiology and Oncology and the Phoenix consensus definitions. A PSA bounce (PSA values of 2 ng/mL or more above nadir) was observed in 15 patients of 123 (9.8%). The median time to bounce was 15.2 months (interquartile range, 11.0-17.7) and the median bounce duration 18.7 months (interquartile range, 12.1-29). The estimate of overall survival at 60 months was 97.1% (95% CI, 91.6-103%). Conclusions: Considering that inverse planned HDR brachytherapy prostate boosts led to an excellent biochemical response, with a 2-year negative biopsy rate, we recommend a conservative approach in face of a PSA bounce even though it was observed in 10% of patients

  15. Fast cross-projection algorithm for reconstruction of seeds in prostate brachytherapy

    International Nuclear Information System (INIS)

    Narayanan, Sreeram; Cho, Paul S.; Marks, Robert J. II

    2002-01-01

    A fast method of seed matching and reconstruction in prostrate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset of seeds in other projections. This subset lies in a proximal region centered about the projection of a line, connecting the seed to its source, onto other projection planes. The proposed technique permits a significant reduction in computational overhead, as measured by the required number of matching tests. The number of multiplications and additions is also vastly reduced at no trade-off in accuracy. Because of its speed, Fast-CARS can be used in applications requiring real-time performance such as intraoperative dosimetry of prostate brachytherapy. Furthermore, the proposed method makes practical the use of a larger number of views as opposed to previous techniques limited to a maximum use of three views

  16. Factors affecting radiation injury after interstitial brachytherapy for brain tumors

    International Nuclear Information System (INIS)

    Leibel, S.A.; Gutin, P.H.; Davis, R.L.

    1991-01-01

    The effects of brachytherapy on normal brain tissue are not easily delineated in the clinical setting because of the presence of concurrent radiation-induced changes in the coexistent brain tumor. Sequential morphologic studies performed after the implantation of radioactive sources into the brains of experimental animals have provided a better understanding of the character and magnitude of the structural changes produced by interstitial irradiation on normal brain tissue. Furthermore, the clinical experience accumulated thus far provides not only relevant information, but also some guidelines for future treatment policies. In this paper, the authors summarize the experimental findings and review the pathologic and clinical features of brain injury caused by interstitial brachytherapy. A number of studies in the older literature examined the effects of radioisotopes such as radium-226 (38--43), radon-22 (44--46), gold-198 (29,47--50), tantalum-182 (29,51,52) yttrium-9- (50,53,54), and cobalt-60 (29,50,55). This review is restricted to low- and high-activity encapsulated iodine-125 ( 125 I) and iridium-192 ( 192 Ir), the isotopes that are most commonly used in current clinical practice

  17. Preparation of high-quality iodine-125-labeled pituitary luteinizing hormone for radioimmunoassay

    International Nuclear Information System (INIS)

    Pinto, H.; Wajchenberg, B.L.; Higa, O.Z.; Toledo e Souza, I.T. de; Werner, R.S.; Pieroni, R.R.

    1974-01-01

    High quality pituitary luteinizing hormone labeled with 125 I was obtained after separating out the more heavily iodinated fractions, through starch gel electrophoresis, using the cathodal component (fraction 1) which was further purified on Sephadex G-100, with the obtention of an almost pure 125 I-LH preparation, presenting excellent immunoreactivity and low levels of damage on incubation in plasma. The quality control of the steps of the technique was done with plasma-coated talc (200 mg) which compared favorably, as far indicating undamaged labeled LH, with the more time-consuming chromatoelectrophoresis

  18. Recurrent primary lumbar vertebra chondrosarcoma: Marginal resection and Iodine-125 seed therapy

    Directory of Open Access Journals (Sweden)

    Chunpeng Ren

    2014-01-01

    Full Text Available Chondrosarcomas are uncommon in the spinal column. En bloc excisions with wide margins are of critical importance but not always feasible in spine. We report the outcome in a case of recurrent lumbar vertebral chondrosarcoma treated with marginal resection and iodine-125 seeds placed in the resected tumor bed.

  19. Investigations on a cortisol-iodine-125-radioimmunoassay test system

    International Nuclear Information System (INIS)

    Hegerl, U.

    1981-01-01

    On the basis of a cortisol-iodine-125-RIA test system the reliability criteria were detected. Additionally, the so-called normal values of the cortisol daily rhythm were determined in a test group with normal metabolism. Moreover, in an other examination control values for the ACTH stimulation were registered and in addition the reproducability of this test was investigated. The results of the examinations and investigations confirm the necessity of taking precision and normal values determined in the own laboratory - as basis for the interpretation of radiochemical substrate analyses. (orig./MG) [de

  20. COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs

    International Nuclear Information System (INIS)

    Melhus, Christopher S.; Rivard, Mark J.

    2008-01-01

    Monte Carlo (MC) simulations were performed to estimate brachytherapy dose distributions for Collaborative Ocular Melanoma Study (COMS) eye plaques. Brachytherapy seed models 200, 6711, and CS-1 Rev2 carrying 103 Pd, 125 I, and 131 Cs radionuclides, respectively, were modeled and benchmarked against previously published values. Calculated dose rate constants MC Λ were 0.684, 0.924, and 1.052 cGy h -1 U -1 (±2.6%, k=1 uncertainty) for models 200, 6711, and CS-1 Rev2, respectively. The seeds were distributed into 10, 12, 14, 16, 18, 20, and 22 mm-diameter COMS eye plaques. Simulations were performed in both heterogeneous and homogeneous environments, where the latter were in-water and the former included the silastic seed carrier insert and gold-alloy plaque. MC-based homogenous central axis dose distributions agreed within 2%±1% (±1 s.d.) to hand-calculated values. For heterogeneous simulations, notable photon attenuation was observed, with dose reduction at 5 mm of 19%, 11%, and 9% for 103 Pd, 125 I, and 131 Cs, respectively. A depth-dependent correction factor was derived to correct homogenous central-axis dose distributions for plaque component heterogeneities, which were found to be significant at short radial distances

  1. A new inexpensive customized plaque for choroidal melanoma iodine-125 plaque therapy

    International Nuclear Information System (INIS)

    Vine, A.K.; Tenhaken, R.K.; Diaz, R.F.; Maxson, B.B.; Lichter, A.S.

    1989-01-01

    The authors have developed a new inexpensive precious metal alloy plaque for use in customized iodine-125 plaque therapy. Each plaque is formed from two flat circular gold/palladium foils which are used in dental crown work. Using a simple manual mechanism, the two forms are stamped over a customized acrylic die shaped to the dimensions of the tumor base plus a 2-mm margin. Completed plaques consist of a back wall, a 2-mm side wall, and a 1.5-mm wide lip with holes for suture placement. Advantages include: simple construction from inexpensive components, customized shape, and iodine seeds that are readily visible on plane radiographs

  2. Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Morton, Gerard C.; Loblaw, D. Andrew; Chung, Hans; Tsang, Gail; Sankreacha, Raxa; Deabreu, Andrea; Zhang Liying; Mamedov, Alexandre; Cheung, Patrick; Batchelar, Deidre; Danjoux, Cyril; Szumacher, Ewa

    2011-01-01

    Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose

  3. Comparison of prostate contours between conventional stepping transverse imaging and Twister-based sagittal imaging in permanent interstitial prostate brachytherapy.

    Science.gov (United States)

    Kawakami, Shogo; Ishiyama, Hiromichi; Satoh, Takefumi; Tsumura, Hideyasu; Sekiguchi, Akane; Takenaka, Kouji; Tabata, Ken-Ichi; Iwamura, Masatsugu; Hayakawa, Kazushige

    2017-08-01

    To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultrasonography probe was inserted, with the patient in lithotomy position. Transverse images were obtained with stepping movement of the transverse transducer. In the same patient, sagittal images were also obtained through rotation of the sagittal transducer using the "Twister" mode. The differences of prostate size among the two types of image acquisitions were compared. The relationships among the difference of the two types of image acquisitions, dose-volume histogram (DVH) parameters on the post-implant computed tomography (CT) analysis, as well as other factors were analyzed. The sagittal image acquisitions showed a larger prostate size compared to the transverse image acquisitions especially in the anterior-posterior (AP) direction ( p transverse image acquisitions was correlated to DVH parameters such as D 90 ( R = 0.518, p = 0.019), and V 100 ( R = 0.598, p = 0.005). There were small but significant differences in the prostate contours between the transverse and the sagittal planning image acquisitions. Furthermore, our study suggested that the differences between the two types of image acquisitions might correlated to dosimetric results on CT analysis.

  4. Microdosimetric evaluation of relative biological effectiveness for 103PD, 125I, 241AM, and 192IR brachytherapy sources

    International Nuclear Information System (INIS)

    Wuu, C.S.; Kliauga, P.; Zaider, M.; Amols, H.I.

    1996-01-01

    Purpose: To determine the microdosimetric-derived relative biological effectiveness (RBE) of 103 Pd, 125 I, 241 Am, and 192 Ir brachytherapy sources at low doses and/or low dose rates. Methods and Materials: The Theory of Dual Radiation Action can be used to predict expected RBE values based on the spatial distribution of energy deposition at microscopic levels from these sources. Single-event lineal energy spectra for these isotopes have been obtained both experimentally and theoretically. A grid-defined wall-less proportional counter was used to measure the lineal energy distributions. Unlike conventional Rossi proportional counters, the counter used in these measurements has a conducting nylon fiber as the central collecting anode and has no metal parts. Thus, the Z-dependence of the photoelectric effect is eliminated as a source of measurement error. Single-event spectra for these brachytherapy sources have been also calculated by: (a) the Monte Carlo code MCNP to generate the electron slowing down spectrum, (b) transport of monoenergetic electron tracks, event by event, with our Monte Carlo code DELTA, (c) using the concept of associated volume to obtain the lineal energy distribution f(y) for each monoenergetic electron, and (d) obtaining the composite lineal energy spectrum for a given brachytherapy source based on the electron spectrum calculated at step (a). Results: Relative to 60 Co, the RBE values obtained from this study are: 2.3 for 103 Pd, 2.1 for 125 I, 2.1 for 241 Am, and 1.3 for 192 Ir. Conclusions: These values are consistent with available data from in vitro cell survival experiments. We suggest that, at least for these brachytherapy sources, microdosimetry may be used as a credible alternative to time-consuming (and often uncertain) radiobiological experiments to obtain information on radition quality and make reliable predictions of RBE in low dose rate brachytherapy

  5. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-01

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V 100 Prostate >90%) and organ-at-risk dose sparing (V 75 Bladder 75 Rectum 125 Urethra <<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter

  6. Impact of learning curve and technical changes on dosimetry in low-dose brachytherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Le Fur, E. [CHU Brest (France). Radiation Therapy Dept.; Universite de Bretagne Occidentale, Brest (France). Faculte de Medecine et des Sciences de la Sante; Malhaire, J.P.; Baverez, D.; Schlurmann, F. [CHU Brest (France). Radiation Therapy Dept.; Delage, F.; Perrouin-Verbe, M.A. [CHU Brest (France). Urology Dept.; Guerif, S. [University Hospital La Miletrie, Poitiers (France). Radiation Therapy Dept.; Poitiers Univ. (France); Fournier, G.; Valeri, A. [CHU Brest (France). Urology Dept.; Universite de Bretagne Occidentale, Brest (France). Faculte de Medecine et des Sciences de la Sante; Universite Europeenne de Bretagne, Rennes (France); APHP, Hopital Tenon, Paris (France). CeRe.PP; Pradier, O. [CHU Brest (France). Radiation Therapy Dept.; Universite de Bretagne Occidentale, Brest (France). Faculte de Medecine et des Sciences de la Sante; Universite Europeenne de Bretagne, Rennes (France); CHU Brest (France). LaTIM, INSERM U650

    2012-12-15

    Purpose: To assess the impact of experience and technical changes on peri- and postimplantation (1 month later) dosimetry for permanent prostate brachytherapy (PPB). Patients and methods: From July 2003 to May 2010, 150 prostate cancer patients underwent low-dose, loose-seed I{sup 125} PPB as monotherapy with intraoperative planning. Patients were divided into three groups - P1 (n = 64), P2 (n = 45), P3 (n = 41) - according to the technical changes that occurred during the study period: use of an automatic stepper at the beginning of P2 and a high-frequency ultrasound probe in P3. Peri- and postimplantation dosimetric parameters (on day 30) were reported: D90 (dose received by 90% of prostate volume), V100 and V150 (prostate volume receiving, respectively, 100% and 150% of the prescribed dose), D2 cc and D0.1 cc (doses received by 2 cc and 0.1 cc of the rectum), R100 (rectum volume that received 100% of the prescribed dose), and D10 and D30 (doses received by 10% and 30% of the urethra, only during peri-implantation). Results: We observed a decrease in the number of needles and seeds used over time. The mean peri-implantation D90 was 187.52 Gy without a significant difference between the three periods (p = 0.48). The postimplantation D90, V100, and V150 parameters were, respectively, 168.3 Gy, 91.9%, and 55% with no significant difference between the three periods. The peri-implantation and postimplantation D0.1 cc and R100 significantly decreased over time; on day 30: D0.1 cc P1 = 223.1 Gy vs. D0.1 cc P3 = 190.4 Gy (p = 8.10- 5) and R100 P1 = 1.06 cc vs. R100 P3 = 0.53 cc (p = 0.0008). Conclusion: We observed a learning curve for the implantation parameters, which led to a significant decrease in the rectal doses without having any impact on the prostate dosimetric parameters. (orig.)

  7. Impact of learning curve and technical changes on dosimetry in low-dose brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Le Fur, E.; Fournier, G.; Valeri, A.; Universite de Bretagne Occidentale, Brest; Universite Europeenne de Bretagne, Rennes; APHP, Hopital Tenon, Paris; Pradier, O.; Universite de Bretagne Occidentale, Brest; Universite Europeenne de Bretagne, Rennes; CHU Brest

    2012-01-01

    Purpose: To assess the impact of experience and technical changes on peri- and postimplantation (1 month later) dosimetry for permanent prostate brachytherapy (PPB). Patients and methods: From July 2003 to May 2010, 150 prostate cancer patients underwent low-dose, loose-seed I 125 PPB as monotherapy with intraoperative planning. Patients were divided into three groups - P1 (n = 64), P2 (n = 45), P3 (n = 41) - according to the technical changes that occurred during the study period: use of an automatic stepper at the beginning of P2 and a high-frequency ultrasound probe in P3. Peri- and postimplantation dosimetric parameters (on day 30) were reported: D90 (dose received by 90% of prostate volume), V100 and V150 (prostate volume receiving, respectively, 100% and 150% of the prescribed dose), D2 cc and D0.1 cc (doses received by 2 cc and 0.1 cc of the rectum), R100 (rectum volume that received 100% of the prescribed dose), and D10 and D30 (doses received by 10% and 30% of the urethra, only during peri-implantation). Results: We observed a decrease in the number of needles and seeds used over time. The mean peri-implantation D90 was 187.52 Gy without a significant difference between the three periods (p = 0.48). The postimplantation D90, V100, and V150 parameters were, respectively, 168.3 Gy, 91.9%, and 55% with no significant difference between the three periods. The peri-implantation and postimplantation D0.1 cc and R100 significantly decreased over time; on day 30: D0.1 cc P1 = 223.1 Gy vs. D0.1 cc P3 = 190.4 Gy (p = 8.10- 5) and R100 P1 = 1.06 cc vs. R100 P3 = 0.53 cc (p = 0.0008). Conclusion: We observed a learning curve for the implantation parameters, which led to a significant decrease in the rectal doses without having any impact on the prostate dosimetric parameters. (orig.)

  8. Poster - 10: QA of Ultrasound Images for Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Szpala, Stanislaw; Kohli, Kirpal S. [BCCA-Fraser Valley Centre (Canada)

    2016-08-15

    Purpose: The current QA protocol of ultrasound systems used in prostate brachytherapy (TG128) addresses geometrical verifications, but the scope of evaluation of image quality is limited. We recognized importance of the latter in routine practice, and designed a protocol for QA of the images. Methods: Images of an ultrasound prostate phantom (CIRS053) were collected with BK Flex Focus 400. The images were saved as bmp after adjusting the gain to 50% for consistent results. Mean pixel values and signal to noise ratio were inspected in the representative sections of the phantom, including the mock prostate and the unechoic medium. Constancy of these numbers over a one year period was looked at. Results: The typical intensity in the mock prostate region in the transverse images ranged between 95 and 118 (out of 256), and the signal to noise was about 10. The intensity in the urethra region was about 170±40, and the unechoic medium was 2±2. The mean and the signal to noise ratio remained almost unchanged after a year, while the signal in the unechoic medium increased to about 7±4. Similar values were obtained in the sagittal images. Conclusions: The image analysis discussed above allows quick evaluation of constancy of the image quality. This may be also useful in troubleshooting image-quality problems during routine exams, which might not be due to deterioration of the US system, but other reasons, e.g. variations in tissue properties or air being trapped between the probe and the anatomy.

  9. Health related quality of life patterns in patients treated with interstitial prostate brachytherapy for localized prostate cancer--data from CaPSURE.

    Science.gov (United States)

    Downs, Tracy M; Sadetsky, Natalia; Pasta, David J; Grossfeld, Gary D; Kane, Christopher J; Mehta, Shilpa S; Carroll, Peter R; Lubeck, Deborah P

    2003-11-01

    We measured the impact brachytherapy monotherapy (BMT) has on general and disease specific health related quality of life (HRQOL) compared to patients treated with radical prostatectomy (RP). We studied 419 men with newly diagnosed prostate cancer who enrolled in CaPSURE (Cancer of the Prostate Strategic Urological Research Endeavor) data base whose primary treatment was brachytherapy monotherapy (92) or radical prostatectomy (327). The validated RAND 36-Item Health Survey and the UCLA Prostate Cancer Index were used to measure HRQOL before treatment and at 6-month intervals during the first 2 years after treatment. Patients treated with BMT or RP did not differ greatly in general HRQOL after treatment. Both treatment groups showed early functional impairment in most general domains with scores returning to or approaching baseline in most domains 18 to 24 months after treatment. Patients treated with BMT had significantly higher urinary function scores at 0 to 6 months after treatment (84.5, SD 18.7) than patients treated with RP (63.3, SD 26.6). Urinary bother scores at 0 to 6 months after treatment were not significantly different between patients treated with BMT (67.7, SD 31.2) and those treated with RP (67.4, SD 29.1). Both treatment groups had decreases in sexual function that did not return to pretreatment levels. Overall BMT and RP are well tolerated procedures that cause mild changes in general HRQOL. Disease specific HRQOL patterns are different in patients treated with BMT or RP. Baseline and serial HRQOL measurements after treatment can provide valuable information regarding expected quality of life outcome after treatment for localized prostate cancer.

  10. Impact of target area selection in 125 Iodine seed brachytherapy on locoregional recurrence in patients with non-small cell lung cancer.

    Science.gov (United States)

    Yan, Wei-Liang; Lv, Jin-Shuang; Guan, Zhi-Yu; Wang, Li-Yang; Yang, Jing-Kui; Liang, Ji-Xiang

    2017-05-01

    Computed tomography (CT)-guided percutaneous implantation of 125 Iodine radioactive seeds requires the precise arrangement of seeds by tumor shape. We tested whether selecting target areas, including subclinical areas around tumors, can influence locoregional recurrence in patients with non-small cell lung cancer (NSCLC). We divided 82 patients with NSCLC into two groups. Target areas in group 1 (n = 40) were defined along tumor margins based on lung-window CT. Target areas in group 2 (n = 42) were extended by 0.5 cm in all dimensions outside tumor margins. Preoperative plans for both groups were based on a treatment plan system, which guided 125 I seed implantation. Six months later, patients underwent chest CT to evaluate treatment efficacy (per Response Evaluation Criteria in Solid Tumors version 1). We compared locoregional recurrences between the groups after a year of follow-up. We then used the treatment plan system to extend target areas for group 1 patients by 0.5 cm (defined as group 3 data) and compared these hypothetical group 3 planned seeds with the actual seed numbers used in group 1 patients. All patients successfully underwent implantation; none died during the follow-up period. Recurrence was significantly lower in group 2 than in group 1 ( P  area for 125 I seeds can decrease recurrence risk by eradicating cancerous lymph-duct blockades within the extended areas. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  11. Computational system to create an entry file for replicating I-125 seeds simulating brachytherapy case studies using the MCNPX code

    Directory of Open Access Journals (Sweden)

    Leonardo da Silva Boia

    2014-03-01

    Full Text Available Purpose: A computational system was developed for this paper in the C++ programming language, to create a 125I radioactive seed entry file, based on the positioning of a virtual grid (template in voxel geometries, with the purpose of performing prostate cancer treatment simulations using the MCNPX code.Methods: The system is fed with information from the planning system with regard to each seed’s location and its depth, and an entry file is automatically created with all the cards (instructions for each seed regarding their cell blocks and surfaces spread out spatially in the 3D environment. The system provides with precision a reproduction of the clinical scenario for the MCNPX code’s simulation environment, thereby allowing the technique’s in-depth study.Results and Conclusion: The preliminary results from this study showed that the lateral penumbra of uniform scanning proton beams was less sensitive In order to validate the computational system, an entry file was created with 88 125I seeds that were inserted in the phantom’s MAX06 prostate region with initial activity determined for the seeds at the 0.27 mCi value. Isodose curves were obtained in all the prostate slices in 5 mm steps in the 7 to 10 cm interval, totaling 7 slices. Variance reduction techniques were applied in order to optimize computational time and the reduction of uncertainties such as photon and electron energy interruptions in 4 keV and forced collisions regarding cells of interest. Through the acquisition of isodose curves, the results obtained show that hot spots have values above 300 Gy, as anticipated in literature, stressing the importance of the sources’ correct positioning, in which the computational system developed provides, in order not to release excessive doses in adjacent risk organs. The 144 Gy prescription curve showed in the validation process that it covers perfectly a large percentage of the volume, at the same time that it demonstrates a large

  12. WE-FG-BRA-02: Docetaxel Eluting Brachytherapy Spacers for Local Chemo-Radiation Therapy in Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Belz, J [Northeastern University, Boston, MA (United States); Kumar, R; Sridhar, S [Northeastern University & Dana Farber Cancer Institute, Boston, MA (United States); Makrigiorgos, G; Nguyen, P [Dana Farber Cancer Institute, Boston, MA (United States); D’Amico, A [Brigham & Women’s Hospital, Boston, MA (United States); Cormack, R [Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: We propose an innovative combinatorial treatment strategy of Local ChemoRadiation Therapy (LCRT) using a sustained drug delivery platform in the form of a spacer to locally radio-sensitize the prostate with Docetaxel (DTX) enabling a synergistic cure with the use of lower radiation doses. These biodegradable spacers are physically similar to the inert spacers routinely used in prostate brachytherapy but are now loaded with formulations of DTX. Methods: Spacers were loaded with ∼500µg Docetaxel (DTX) for prostate cancer studies. The implants were characterized in vitro using SEM and HPLC. The release kinetic studies were carried out in buffer (pH 6.0) at 37°C. Subcutaneous PC3 tumors were xenografted in nude mice. Prostate cancer studies were done with and without radiation using SARRP at 5Gy, 10Gy, and 15Gy. Drug-loaded implants were injected once intratumorally using an 18G brachytherapy needle. Results: The release study in vitro showed a highly sustained release for multiple weeks at therapeutically relevant doses. The monotherapy with local DTX spacer showed sustained tumor inhibition compared to empty implants and an equivalent DTX dose given systemically. At 40 days, 89% survival was observed for mice treated with DTX implants compared with 0% in all other treatment groups. The combined treatment with local DTX spacer and radiation (10Gy) showed the highest degree of tumor suppression (significant tumor growth inhibition by day 90). The control mice showed continuous tumor growth and were scarified by day 56. Groups of mice treated with DTX-spacer or radiation alone showed initial tumor suppression but growth continued after day 60. A larger experiment is ongoing. Conclusion: This approach provides localized delivery of the chemotherapeutic sensitizer directly to the tumor and avoids the toxicities associated with both brachytherapy and current systemic delivery of docetaxel. Sustained release of DTX is an effective chemotherapy option alone or

  13. Low risk of urinary incontinence following prostate brachytherapy in patients with a prior transurethral prostate resection

    International Nuclear Information System (INIS)

    Wallner, Kent; Lee, Henry; Wasserman, Stuart; Dattoli, Michael

    1997-01-01

    Purpose: To review post implant morbidity in patients with prior transurethral prostate resection (TURP). Methods and Materials: Nineteen patients with stage T1-T2 prostatic carcinoma and prior TURP were treated with I-125 or Pd-103 implantation from 1991 through 1994. Follow-up ranged from 1 to 6 years (median: 3 years). The time from TURP to implantation ranged from 2 months to 15 years (median: 3 years). Results: Only one patient developed mild urinary stress incontinence, 6 months following his I-125 implant. The actuarial freedom from permanent urinary incontinence at 3 years after implantation was 94%. No patient required urethral dilatation for urethral stricture. Eleven patients were sexually potent prior to implantation. At 3 years after treatment, all patients had maintained potency. Conclusion: In our experience, there has been remarkably little adverse sequelae following I-125 or Pd-103 implantation in patients with a prior history of TURP

  14. Development of a tapping device: a new needle insertion method for prostate brachytherapy

    International Nuclear Information System (INIS)

    Lagerburg, V; Moerland, M A; Konings, M K; Vosse, R E van de; Lagendijk, J J W; Battermann, J J

    2006-01-01

    The purpose of this study is to develop and test a tapping device for needle insertion for prostate brachytherapy. This device will tap the needle into the prostate with a certain, well-defined, amount of momentum, instead of the currently used method of pushing the needle. Because of the high needle insertion velocity, we expect prostate motion and deformation to be less compared to current methods. We measured the momentum that is applied when manually tapping the needle into the prostate and found a mean momentum of 0.50 ± 0.07 N s. The tapping device is pneumatically driven and we found that the delivered momentum increased linearly with the applied air pressure. The efficacy of the tapping device was tested on a piece of beef, placed on a freely moving and rotating platform. A significant correlation was found between the applied pressure and the rotation and displacement of the beef. Displacements and rotations were minimal for the highest pressure (4 bar) and amounted to only 2 mm and 6 deg., respectively. Higher air pressures will further reduce displacements and rotations

  15. Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition

    Energy Technology Data Exchange (ETDEWEB)

    Landry, Guillaume; Reniers, Brigitte; Murrer, Lars; Lutgens, Ludy; Bloemen-Van Gurp, Esther; Pignol, Jean-Philippe; Keller, Brian; Beaulieu, Luc; Verhaegen, Frank [Department of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Departement de Radio-Oncologie et Centre de Recherche en Cancerologie, de l' Universite Laval, CHUQ, Pavillon L' Hotel-Dieu de Quebec, Quebec G1R 2J6 (Canada) and Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec G1K 7P4 (Canada); Department of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands) and Medical Physics Unit, McGill University, Montreal General Hospital, Montreal, Quebec H3G 1A4 (Canada)

    2010-10-15

    Purpose: The objective of this work is to assess the sensitivity of Monte Carlo (MC) dose calculations to uncertainties in human tissue composition for a range of low photon energy brachytherapy sources: {sup 125}I, {sup 103}Pd, {sup 131}Cs, and an electronic brachytherapy source (EBS). The low energy photons emitted by these sources make the dosimetry sensitive to variations in tissue atomic number due to the dominance of the photoelectric effect. This work reports dose to a small mass of water in medium D{sub w,m} as opposed to dose to a small mass of medium in medium D{sub m,m}. Methods: Mean adipose, mammary gland, and breast tissues (as uniform mixture of the aforementioned tissues) are investigated as well as compositions corresponding to one standard deviation from the mean. Prostate mean compositions from three different literature sources are also investigated. Three sets of MC simulations are performed with the GEANT4 code: (1) Dose calculations for idealized TG-43-like spherical geometries using point sources. Radial dose profiles obtained in different media are compared to assess the influence of compositional uncertainties. (2) Dose calculations for four clinical prostate LDR brachytherapy permanent seed implants using {sup 125}I seeds (Model 2301, Best Medical, Springfield, VA). The effect of varying the prostate composition in the planning target volume (PTV) is investigated by comparing PTV D{sub 90} values. (3) Dose calculations for four clinical breast LDR brachytherapy permanent seed implants using {sup 103}Pd seeds (Model 2335, Best Medical). The effects of varying the adipose/gland ratio in the PTV and of varying the elemental composition of adipose and gland within one standard deviation of the assumed mean composition are investigated by comparing PTV D{sub 90} values. For (2) and (3), the influence of using the mass density from CT scans instead of unit mass density is also assessed. Results: Results from simulation (1) show that variations

  16. In vivo imaging of insulin receptors by PET: preclinical evaluation of iodine-125 and iodine-124 labelled human insulin

    International Nuclear Information System (INIS)

    Iozzo, P.; Osman, S.; Glaser, M.; Knickmeier, M.; Ferrannini, E.; Pike, V.W.; Camici, P.G.; Law, M.P.

    2002-01-01

    [A 14 -*I]iodoinsulin was prepared for studies to assess the suitability of labeled iodoinsulin for positron emission tomography (PET). Iodine-125 was used to establish the methods and for preliminary studies in rats. Further studies and PET scanning in rats were carried out using iodine-124. Tissue and plasma radioactivity was measured as the uptake index (UI={cpm·(g tissue) -1 }/{cpm injected·(g body weight) -1 }) at 1 to 40 min after intravenous injection of either [A 14 - 125 I]iodoinsulin or [A 14 - 124 I]iodoinsulin. For both radiotracers, initial clearance of radioactivity from plasma was rapid (T 1/2 ∼ 1 min), reaching a plateau (UI = 2.8) at ∼ 5 min which was maintained for 35 min. Tissue biodistributions of the two radiotracers were comparable; at 10 min after injection, UI for myocardium was 2.4, liver, 4.0, pancreas, 5.4, brain, 0.17, kidney, 22, lung, 2.3, muscle, 0.54 and fat, 0.28. Predosing rats with unlabelled insulin reduced the UI for myocardium (0.95), liver (1.8), pancreas (1.2) and brain (0.08), increased that for kidney (61) but had no effect on that for lung (2.5), muscle (0.50) or fat (0.34). Analysis of radioactivity in plasma demonstrated a decrease of [ 125 I]iodoinsulin associated with the appearance of labeled metabolites; the percentage of plasma radioactivity due to [ 125 I]iodoinsulin was 40% at 5 min and 10% at 10 min. The heart, liver and kidneys were visualized using [ 124 I]iodoinsulin with PET

  17. Radiobiologically based treatment plan evaluation for prostate seed implants

    Directory of Open Access Journals (Sweden)

    Sotirios Stathakis

    2011-07-01

    Full Text Available Purpose: Accurate prostate low dose-rate brachytherapy treatment plan evaluation is important for future care decisions. Presently, an evaluation is based on dosimetric quantifiers for the tumor and organs at risk. However, these do not account for effects of varying dose-rate, tumor repopulation and other biological effects. In this work, incorporation of the biological response is used to obtain more clinically relevant treatment plan evaluation.Material and methods: Eleven patients were evaluated. Each patient received a 145 Gy implant. Iodine-125 seeds were used and the treatment plans were created on the Prowess system. Based on CT images the post-implant plan was created. In the post-plan, the tumor, urethra, bladder and rectum were contoured. The biologically effective dose was used to determine the tumor control probability and the normal tissue complication probabilities for the urethra, bladder, rectum and surrounding tissue. Results: The average tumor control probability and complication probabilities for the urethra, bladder, rectum and surrounding tissue were 99%, 29%, 0%, 12% and 6%, respectively. These measures provide a simpler means for evaluation and since they include radiobiological factors, they provide more reliable estimation of the treatment outcome. Conclusions: The goal of this work was to create more clinically relevant prostate seed-implant evaluation by incorporating radiobiological measures. This resulted in a simpler descriptor of treatment plan quality and was consistent with patient outcomes.

  18. Regulation of autophagy via PERK-eIF2α effectively relieve the radiation myelitis induced by iodine-125.

    Directory of Open Access Journals (Sweden)

    Zuozhang Yang

    Full Text Available Radiation myelitis is the most serious complication in clinical radiotherapy for spinal metastases. We previously showed that (125I brachytherapy induced apoptosis of spinal cord neurons accompanied by autophagy. In this study, we further investigated the mechanism by which (125I radiation triggered autophagy in neural cells. We found that autophagy induced by (125I radiation was involved in endoplasmic reticulum (ER stress and mainly dependent on PERK-eIF2α pathway. The expressions of LC3II, ATG12 and PI3K were significantly suppressed in PERK knockout neural cells. Meanwhile, the expressions of phosphorylated-Akt s473 and caspase3/8 all significantly increased in neural cells transfected with a PERK siRNA and which enhanced apoptosis of neurons after (125I radiation. The results were consistent with that by MTT and Annexin-FITC/PT staining. In animal model of banna pigs with radiation myelitis caused by (125I brachytherapy, we have successfully decreased PERK expression by intrathecal administration of the lentivirus vector. The apoptosis rate was significantly higher than that in control group and which deteriorated radiation myelitis of banna pigs. Thus, autophagy caused by (125I radiation was mainly as an attempt of cell survival at an early stage, but it would be a self-destructive process and promoted the process of apoptosis and necrosis radiated by (125I for more than 72 hours. The study would be useful and helpful to maximize efficiency of radiation therapy in clinical therapy.

  19. Iodine-125--digoxin radioimmunoassay: comparison of commercial kits

    International Nuclear Information System (INIS)

    Battaglia, D.J.; Cianci, M.L.

    1976-01-01

    Iodine-125-digoxin radioimmunoassay kits available from Abbott Diagnostics (AD), Dade Division (D), Schwarz/Mann (SM), and Clinical Assays (CA) were evaluated with respect to assay quality. The kit accuracies did not differ significantly at 2.0 ng/ml and the interassay coefficients of variation ranged from 9 percent (AD) to 21.4 percent (CA). The accuracy for all kits above 4 ng/ml is questionable, and since serum-dilution values correlated well with undiluted serum values, the dilution method of dose quantitation is preferable for levels above 4 ng/ml. Although all the kits were adequate for evaluating digoxin at the 2 ng/ml level, the Abbott kit seems to be of slightly better quality

  20. Dosimetric studies, spectrometric, radiographic, metallographic of a new argentinean seed of {sup 125} I used in brachytherapy; Estudios dosimetricos, espectrometricos, radiograficos, metalograficos de una nueva semilla argentina de {sup 125}I empleada en braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Pirchio, R.; Saravi, M.; Banchik, D.; Munoz, C. [CNEA, Pbro. J. Gonzalez y Aragon No. 15 (B1802AYA), Ezeiza, Buenos Aires (Argentina)]. e-mail: pirchio@cae.cnea.gov.ar

    2006-07-01

    A new source of {sup 125} I model Braquibac{sup TM} has been developed in Argentina for applications in interstitial brachytherapy. The AAPM Task Group 43 (TG-43) recommends that dosimetric characteristics of new sources of brachytherapy of Iodine-125 have been theoretically and experimentally determined before its clinical use. The objectives outlined in this work were the study of the design of the new seed, the calculation of dosimetric parameters and the photons spectra analysis. Its were carried out radiographic and metallographic studies to determine the physical characteristics of the source. For the realization of the dosimetric calculations it was used the Monte Carlo code MCNP5. Values of the radial dose function, g(r), of the constant of dose rate, {lambda}, of the function of anisotropy of two dimensions, F(r, {theta}), of the factor and constant of anisotropy its were obtained simulating the source in water according to the recommended methodology in TG-43. The constant of dose rate is similar to 0,880 {+-} 0,080 c Gy h{sup -1} U{sup -1}. The kerma in air rate of reference, S{sub K}, was calculated as 1,036 c Gy cm{sup 2}h{sup -1} mCi{sup -1} simulating the seed in dry air. Its were carried out spectrometric studies using a semiconductor planar detector of HPGe (high purity germanium). Photons spectra showed characteristic x-rays of {sup 125} I with energies of 27,20 keV, 27,47 keV, 31 keV and 31,70 keV gamma photons of 35,5 keV, and x-ray fluorescent coming from the silver nucleus of 22,10 keV, 24,94 keV and 25,45 keV. The angular dependence of the intensity of photons around the seed and in air it was analyzed with the planar detector. This was carried out to study the anisotropy in the photons flow due to variation in the thickness of the titanium wall and of the welding, movements of the silver tube inside the source and deposition of the radioactive material on the silver tube. (Author)

  1. Analysis of the testicular dose in patients undergoing radiotherapy for carcinoma of the prostate

    International Nuclear Information System (INIS)

    Bejar Navarro, M. J.; Ordonez Marquez, J.; Hervas Moron, A.; Alvarez Rodriguez, S.; Garcia-Galloway, E.; Sanchez Casanueva, R.; Polo Rubio, A.; Rodriguez-Patron, R.; Yanowsky, K.; Gomez Dos Santos, V.

    2013-01-01

    The objectives of this work are: -Studying comparatively the doses received in testes in patients undergoing radiotherapy of prostate carcinoma with external beam radiation and brachytherapy of low rate using I-125 seeds. -Compare doses due to images of verification using Cone Beam CT (CBCT), with doses of radiotherapy treatment itself. -Determine the seminal alterations and cytogenetic after treatment with ionizing radiation (RTE or BQT) in patients diagnosed with prostate cancer and its relation with testicular dose. (Author)

  2. SU-E-J-232: Feasibility of MRI-Based Preplan On Low Dose Rate Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Y; Tward, J; Rassiah-Szegedi, P; Zhao, H; Sarkar, V; Huang, L; Szegedi, M; Kokeny, K; Salter, B [University of Utah Huntsman Cancer Institute, Salt Lake City, UT (United States)

    2015-06-15

    Purpose: To investigate the feasibility of using MRI-based preplan for low dose rate prostate brachytherapy. Methods: 12 patients who received transrectal ultrasound (TRUS) guided prostate brachytherapy with Pd-103 were retrospectively studied. Our care-standard of the TRUS-based preplan served as the control. One or more prostate T2-weighted wide and/or narrow-field of view MRIs obtained within the 3 months prior to the implant were imported into the MIM Symphony software v6.3 (MIM Software Inc., Cleveland, OH) for each patient. In total, 37 MRI preplans (10 different image sequences with average thickness of 4.8mm) were generated. The contoured prostate volume and the seed counts required to achieve adequate dosimetric coverage from TRUS and MRI preplans were compared for each patient. The effects of different MRI sequences and image thicknesses were also investigated statistically using Student’s t-test. Lastly, the nomogram from the MRI preplan and TRUS preplan from our historical treatment data were compared. Results: The average prostate volume contoured on the TRUS and MRI were 26.6cc (range: 12.6∼41.3cc), and 27.4 cc (range: 14.3∼50.0cc), respectively. Axial MRI thicknesses (range: 3.5∼8.1mm) did not significantly affect the contoured volume or the number of seeds required on the preplan (R2 = 0.0002 and 0.0012, respectively). Four of the MRI sequences (AX-T2, AX-T2-Whole-Pelvis, AX-T2-FSE, and AXIALT2- Hi-Res) showed statistically significant better prostate volume agreement with TRUS than the other seven sequences (P <0.01). Nomogram overlay between the MRI and TRUS preplans showed good agreement; indicating volumes contoured on MRI preplan scan reliably predict how many seeds are needed for implant. Conclusion: Although MRI does not allow for determination of the actual implant geometry, it can give reliable volumes for seed ordering purposes. Our future work will investigate if MRI is sufficient to reliably replace TRUS preplanning in patients

  3. High-Dose-Rate Brachytherapy Boost for Prostate Cancer: Comparison of Two Different Fractionation Schemes

    International Nuclear Information System (INIS)

    Kaprealian, Tania; Weinberg, Vivian; Speight, Joycelyn L.; Gottschalk, Alexander R.; Roach, Mack; Shinohara, Katsuto; Hsu, I.-Chow

    2012-01-01

    Purpose: This is a retrospective study comparing our experience with high-dose-rate (HDR) brachytherapy boost for prostate cancer, using two different fractionation schemes, 600 cGy × 3 fractions (patient group 1) and 950 cGy × 2 fractions (patient group 2). Methods and Materials: A total of 165 patients were treated for prostate cancer using external beam radiation therapy up to a dose of 45 Gy, followed by an HDR brachytherapy prostate radiation boost. Between July 1997 and Nov 1999, 64 patients were treated with an HDR boost of 600 cGy × 3 fractions; and between June 2000 and Nov 2005, 101 patients were treated with an HDR boost of 950 cGy × 2 fractions. All but 9 patients had at least one of the following risk features: pretreatment prostate-specific antigen (PSA) level >10, a Gleason score ≥7, and/or clinical stage T3 disease. Results: Median follow-up was 105 months for group 1 and 43 months for group 2. Patients in group 2 had a greater number of high-risk features than group 1 (p = 0.02). Adjusted for comparable follow-up, there was no difference in biochemical no-evidence-of-disease (bNED) rate between the two fractionation scheme approaches, with 5-year Kaplan-Meier estimates of 93.5% in group 1 and 87.3% in group 2 (p = 0.19). The 5-year estimates of progression-free survival were 86% for group 1 and 83% for group 2 (p = 0.53). Among high-risk patients, there were no differences in bNED or PFS rate due to fractionation. Conclusions: Results were excellent for both groups. Adjusted for comparable follow-up, no differences were found between groups.

  4. Iodine-125 irradiation of choroidal melanoma: clinical experience from the Prince of Wales and Sydney Eye Hospitals.

    Science.gov (United States)

    Mameghan, H; Karolis, C; Fisher, R; Mameghan, J; Billson, F A; Donaldson, E J; Giblin, M E; Hunyor, A B

    1992-08-01

    We examined the records of 53 patients treated for choroidal melanoma between 1985 and 1989. The aim of this study was to assess the safety and short-term results of iodine-125 episcleral plaque therapy. There were 28 males and 25 females, aged 20 to 77 years (median 61 years), treated for single tumours with a median diameter of 9 mm (range 5 to 15 mm) and with a median thickness of 4 mm (range 2 to 10 mm). The plaques containing iodine-125 seeds were chosen according to tumour size: 10 mm (16 patients); 15 mm (36 patients); 20 mm (one patient). All patients are alive at last follow-up (median 1.3 years, range 4 months to 3.3 years). Four patients underwent enucleation for melanoma progression. Thirty patients have developed some type of complication (more than one complication occurred in the same eye in 12 patients): retinitis (19), optic neuropathy (7); cataract (4), rubeosis iridis (2). Overall, visual acuity deteriorated in 32 patients, remained stable in 12 patients and improved in 9 patients. Iodine-125 plaque therapy appears to offer patients good prospects of tumour control and preservation of useful vision.

  5. Edema associated with I-125 or Pd-103 prostate brachytherapy and its impact on post-implant dosimetry: an analysis based on serial CT acquisition

    International Nuclear Information System (INIS)

    Waterman, Frank M.; Yue, Ning; Corn, Benjamin W.; Dicker, Adam P.

    1998-01-01

    Purpose: To characterize the magnitude and duration of post-implant edema following the implantation of I-125 or Pd-103 seeds into the prostate and to investigate its effect on the CT-based calculation of the total dose delivered by the implant. Materials and Methods: A pre-implant CT scan and 3 to 5 serial post-implant CT scans were obtained on 10 patients who received either I-125 or Pd-103 seed implants. None of the patients received hormone therapy. The magnitude and duration of edema were determined from the change in the spatial distribution of the implanted seeds as the edema resolves. Dose volume histograms were compiled to determine the percentage of the prostate volume that received a dose equal to, or greater than, the prescribed dose. Results: The magnitude of the edema, expressed as the ratio of the post- to pre-implant volume on the day of the procedure, ranged from 1.33 to 1.96 (mean 1.52). The edema decreased exponentially with time; however, the edema half-life (time for the edema to decrease by 1/2) varied from 4 to 25 days (mean 9.3 days). As the edema resolved, the percentage of the prostate that received a dose equal to or greater than the prescribed dose increased by at least 7% in 7 of the 10 patients and increased by more than 15% in 2. In those patients in whom dose coverage was unaffected by the resolution of edema, more than 90% of the prostate was covered by the prescribed dose in the initial CT scan. Conclusion: Post-implant edema increased the prostate volume by factors which ranged from 1.33 to 1.96 (mean: 1.52). The edema resolved exponentially with an edema half-life which varied from 4 to 25 days (mean: 9.3 days). Edema had a significant effect on the post-implant dosimetry in 7 of 10 cases. Factors that affect the impact of edema on the dosimetry are the magnitude of the edema and the planned margin between the prescribed isodose line and the periphery of the prostate

  6. MO-B-BRC-02: Ultrasound Based Prostate HDR

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Z. [Duke University Medical Center (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  7. MO-B-BRC-02: Ultrasound Based Prostate HDR

    International Nuclear Information System (INIS)

    Chang, Z.

    2016-01-01

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions

  8. MO-B-BRC-04: MRI-Based Prostate HDR

    International Nuclear Information System (INIS)

    Mourtada, F.

    2016-01-01

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions

  9. MO-B-BRC-03: CT-Based Prostate HDR

    International Nuclear Information System (INIS)

    Zoberi, J.

    2016-01-01

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions

  10. MO-B-BRC-04: MRI-Based Prostate HDR

    Energy Technology Data Exchange (ETDEWEB)

    Mourtada, F. [Christiana Care Hospital (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  11. MO-B-BRC-03: CT-Based Prostate HDR

    Energy Technology Data Exchange (ETDEWEB)

    Zoberi, J. [Washington University School of Medicine (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  12. A quantitative analysis of two-dimensional manually segmented transrectal ultrasound axial images in planning high dose rate brachytherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Dabić-Stanković Kata

    2017-01-01

    Full Text Available Background/Aim. Prostate delineation, pre-planning and catheter implantation procedures, in high-dose rate brachytherapy (HDR-BT, are commonly based on the prostate manually segmented transrectal ultrasound (TRUS images. The aim of this study was to quantitatively analyze the consistency of prostate capsule delineation, done by a single therapist, prior to each HDR-BT fraction and the changes in the shape of the prostate capsule during HDR-BT, using two dimensional (2D TRUS axial image. Methods. A group of 16 patients were treated at the Medical System Belgrade Brachytherapy Department with definitive HDRBT. The total applied median dose of 52 Gy was divided into four individual fractions, each fraction being delivered 2– 3 weeks apart. Real time prostate axial visualization and the manual segmentation prior to each fraction were performed using B-K Medical ultrasound. Quantitative analyses, analysis of an area and shape were applied on 2D-TRUS axial images of the prostate. Area analyses were used to calculate the average value of the cross-sectional area of the prostate image. The parameters of the prostate shape, the fractal dimension and the circularity ratio of the prostate capsule contour were estimated at the maximum axial cross section of the prostate image. Results. The sample group consisted of four phases, each phase being performed prior to the first, second, third and fourth HDR-BT fraction, respectively. Statistical analysis showed that during HDR-BT fractions there were no significant differences in the average value of area, as well as in the maximum shape of prostate capsule. Conclusions. Quantitative analysis of TRUS axial prostate segmented images shows a successful capsule delineation in the series of manually segmented TRUS images, and the prostate maximum shape remaining unchanged during HDR-BT fractions.

  13. Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Ito, Kazuto; Saitoh, Jun-ichi; Noda, Shin-ei; Harashima, Koichi; Sakurai, Hideyuki; Nakayama, Yuko; Yamamoto, Takumi; Suzuki, Kazuhiro; Nakano, Takashi; Niibe, Hideo

    2005-01-01

    Purpose: Several investigations have revealed that the α/β ratio for prostate cancer is atypically low, and that hypofractionation or high-dose-rate (HDR) brachytherapy regimens using appropriate radiation doses may be expected to yield tumor control and late sequelae rates that are better or at least as favorable as those achieved with conventional radiation therapy. In this setting, we attempted treating localized prostate cancer patients with HDR brachytherapy combined with hypofractionated external beam radiation therapy (EBRT). The purpose of this study was to evaluate the feasibility of using this approach, with special emphasis on the relationship between the severity of acute genitourinary (GU) toxicity and the urethral dose calculated from the dose-volume histogram (DVH) of HDR brachytherapy. Methods and Materials: Between September 2000 and December 2003, 70 patients with localized prostate cancer were treated by iridium-192 HDR brachytherapy combined with hypofractionated EBRT at the Gunma University Hospital. Hypofractionated EBRT was administered in fraction doses of 3 Gy, three times per week; a total dose of 51 Gy was delivered to the prostate gland and the seminal vesicles using the four-field technique. No elective pelvic irradiation was performed. After the completion of EBRT, all the patients additionally received transrectal ultrasonography (TRUS)-guided HDR brachytherapy. The fraction size and the number of fractions in HDR brachytherapy were prospectively changed, whereas the total radiation dose for EBRT was fixed at 51 Gy. The fractionation in HDR brachytherapy was as follows: 5 Gy x 5, 7 Gy x 3, 9 Gy x 2, administered twice per day, although the biologic effective dose (BED) for HDR brachytherapy combined with EBRT, assuming that the α/β ratio is 3, was almost equal to 138 in each fractionation group. The planning target volume was defined as the prostate gland with 5-mm margin all around, and the planning was conducted based on

  14. Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements.

    Science.gov (United States)

    Poder, Joel; Whitaker, May

    2016-06-01

    Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected.

  15. Needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer evaluated by repeated MRI.

    Science.gov (United States)

    Buus, Simon; Lizondo, Maria; Hokland, Steffen; Rylander, Susanne; Pedersen, Erik M; Tanderup, Kari; Bentzen, Lise

    To quantify needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer and propose a threshold for needle migration. Twenty-four high-risk prostate cancer patients treated with an HDR boost of 2 × 8.5 Gy were included. Patients received an MRI for planning (MRI1), before (MRI2), and after treatment (MRI3). Time from needle insertion to MRI3 was ∼3 hours. Needle migration was evaluated from coregistered images: MRI1-MRI2 and MRI1-MRI3. Dose volume histogram parameters from the treatment plan based on MRI1 were related to parameters based on needle positions in MRI2 or MRI3. Regression was used to model the average needle migration per implant and change in D90 clinical target volume, CTV prostate+3mm . The model fit was used for estimating the dosimetric impact in equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy. Needle migration was on average 2.2 ± 1.8 mm SD from MRI1-MRI2 and 5.0 ± 3.0 mm SD from MRI1-MRI3. D90 CTV prostate+3mm was robust toward average needle migration ≤3 mm, whereas for migration >3 mm D90 decreased by 4.5% per mm. A 3 mm of needle migration resulted in a decrease of 0.9, 1.7, 2.3, 4.8, and 7.6 equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy, respectively. Substantial needle migration in high-dose-rate brachytherapy occurs frequently in 1-3 hours following needle insertion. A 3-mm threshold of needle migration is proposed, but 2 mm may be considered for dose levels ≥15 Gy. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  16. Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

    Energy Technology Data Exchange (ETDEWEB)

    Poon, Justin; Sabondjian, Eric; Sankreacha, Raxa [University of British Columbia, Dept. of Physics and Astronomy, Vancouver, BC (Canada); Trillium Health Partners – Credit Valley Hospital, Peel Regional Cancer Centre, Mississauga, ON, Trillium Health Partners – Credit Valley Hospital, Peel Regional Cancer Centre, Mississauga, ON, Trillium Health Partners – Credit Valley Hospital, Peel Regional Cancer Centre, Mississauga, ON (Canada); University of Toronto, Dept. of Radiation Oncology, Toronto, ON (Canada)

    2016-08-15

    Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasound scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.

  17. Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

    International Nuclear Information System (INIS)

    Poon, Justin; Sabondjian, Eric; Sankreacha, Raxa

    2016-01-01

    Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasound scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.

  18. Brachytherapy Boost Utilization and Survival in Unfavorable-risk Prostate Cancer.

    Science.gov (United States)

    Johnson, Skyler B; Lester-Coll, Nataniel H; Kelly, Jacqueline R; Kann, Benjamin H; Yu, James B; Nath, Sameer K

    2017-11-01

    There are limited comparative survival data for prostate cancer (PCa) patients managed with a low-dose rate brachytherapy (LDR-B) boost and dose-escalated external-beam radiotherapy (DE-EBRT) alone. To compare overall survival (OS) for men with unfavorable PCa between LDR-B and DE-EBRT groups. Using the National Cancer Data Base, we identified men with unfavorable PCa treated between 2004 and 2012 with androgen suppression (AS) and either EBRT followed by LDR-B or DE-EBRT (75.6-86.4Gy). Treatment selection was evaluated using logistic regression and annual percentage proportions. OS was analyzed using the Kaplan-Meier method, log-rank test, Cox proportional hazards, and propensity score matching. We identified 25038 men between 2004 and 2012, during which LDR-B boost utilization decreased from 29% to 14%. LDR-B was associated with better OS on univariate (7-yr OS: 82% vs 73%; pLDR-B boost (HR 0.74, 95% CI 0.66-0.89). The OS benefit of LDR-B boost persisted when limited to men aged LDR-B boost utilization declined and was associated with better OS compared to DE-EBRT alone. LDR-B boost is probably the ideal treatment option for men with unfavorable PCa, pending long-term results of randomized trials. We compared radiotherapy utilization and survival for prostate cancer (PCa) patients using a national database. We found that low-dose rate brachytherapy (LDR-B) boost, a method being used less frequently, was associated with better overall survival when compared to dose-escalated external-beam radiotherapy alone for men with unfavorable PCa. Randomized trials are needed to confirm that LDR-B boost is the ideal treatment. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  19. Multistation iodine-125 continuous air monitor with minicomputer alarm and data reduction

    International Nuclear Information System (INIS)

    Garfield, D.K.

    1978-01-01

    The components, operation, and calibration are described of a Multistation Continuous Air Monitor for the analysis of Iodine-125 and the functions of the Minicomputer in providing alarm functions and data reduction to units specified by regulation for permanent records. The sensitivity and accuracy, as well as the justification for purchase and comparison of costs with other types of air monitoring systems are also described

  20. Brachytherapy boost and cancer-specific mortality in favorable high-risk versus other high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Vinayak Muralidhar

    2016-02-01

    Full Text Available Purpose : Recent retrospective data suggest that brachytherapy (BT boost may confer a cancer-specific survival benefit in radiation-managed high-risk prostate cancer. We sought to determine whether this survival benefit would extend to the recently defined favorable high-risk subgroup of prostate cancer patients (T1c, Gleason 4 + 4 = 8, PSA 20 ng/ml. Material and methods: We identified 45,078 patients in the Surveillance, Epidemiology, and End Results database with cT1c-T3aN0M0 intermediate- to high-risk prostate cancer diagnosed 2004-2011 treated with external beam radiation therapy (EBRT only or EBRT plus BT. We used multivariable competing risks regression to determine differences in the rate of prostate cancer-specific mortality (PCSM after EBRT + BT or EBRT alone in patients with intermediate-risk, favorable high-risk, or other high-risk disease after adjusting for demographic and clinical factors. Results : EBRT + BT was not associated with an improvement in 5-year PCSM compared to EBRT alone among patients with favorable high-risk disease (1.6% vs. 1.8%; adjusted hazard ratio [AHR]: 0.56; 95% confidence interval [CI]: 0.21-1.52, p = 0.258, and intermediate-risk disease (0.8% vs. 1.0%, AHR: 0.83, 95% CI: 0.59-1.16, p = 0.270. Others with high-risk disease had significantly lower 5-year PCSM when treated with EBRT + BT compared with EBRT alone (3.9% vs. 5.3%; AHR: 0.73; 95% CI: 0.55-0.95; p = 0.022. Conclusions : Brachytherapy boost is associated with a decreased rate of PCSM in some men with high-risk prostate cancer but not among patients with favorable high-risk disease. Our results suggest that the recently-defined “favorable high-risk” category may be used to personalize therapy for men with high-risk disease.