WorldWideScience

Sample records for iodinated contrast medium

  1. Role of hemolysis in potassium release by iodinated contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, K.; Nakamura, T.; Shimizu, Y. [Department of Radiology, Kyoto City Hospital (Japan)

    1999-09-01

    It has been demonstrated that an iodinated contrast medium (CM) causes release of potassium into blood vessel lumina, resulting in an increase in serum potassium. The purpose of the present study was to assess whether this potassium release is due to hemolysis. Fresh human blood was mixed in vitro with CM at a ratio of 10:2. Potassium release rates were determined, and serum haptoglobin and free hemoglobin were measured after 30 min of exposure to CM. To compare the potassium release curve between CM exposure and true hemolysis induced by distilled water, fresh human blood was also mixed with distilled water. The level of serum haptoglobin decreased due to hemodilution. Changes in haptoglobin were not correlated with potassium release rates. The serum free hemoglobin level did not increase significantly, and there was no correlation between changes in the free hemoglobin level and the rate of potassium release. Hemolysis caused by water occurred instantaneously, whereas potassium release caused by CM was a slow response, which was linearly correlated with exposure time. Potassium release from blood cannot be explained by hemolysis. (orig.) With 4 figs., 4 tabs., 3 refs.

  2. Efficacy of high iodine concentration contrast medium with saline pushing in hepatic CT in patients with chronic liver disease. Comparison of high doses-standard contrast medium concentration

    International Nuclear Information System (INIS)

    Matoba, Munetaka; Kondo, Tamaki; Nishikawa, Takahiro; Kuginuki, Yasuaki; Yokota, Hajime; Higashi, Kotaro; Tonami, Hisao

    2006-01-01

    The aim of this study was to compare the enhancement of liver parenchyama with high iodine concentration contrast medium with saline pushing to that with high doses standard iodine concentration in hepatic CT in patients with chronic liver disease. There was no statistically significant difference regarding to the enhancement of liver parenchyama between the 370 mgI/ml of contrast medium with saline pushing and high doses standard iodine concentration contrast medium. (author)

  3. A method to evaluate the dose increase in CT with iodinated contrast medium

    International Nuclear Information System (INIS)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio

    2010-01-01

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical protocols

  4. A method to evaluate the dose increase in CT with iodinated contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio [Department of Radiological Sciences, University of Messina, Messina 98125 (Italy); Department of Physics, University of Messina, Messina 98166 (Italy); University Hospital ' ' G. Martino' ' , Messina 98125 (Italy); Department of Radiological Sciences, University of Messina, Messina 98125 (Italy) and University Hospital ' ' G. Martino' ' , Messina 98125 (Italy)

    2010-08-15

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical

  5. A case of pulmonary edema developed after intraarterial injection of iodinated contrast medium

    International Nuclear Information System (INIS)

    Min, Byoung Chol; Chun, Kang Woo; Koh, Jae Hyu; Yoon, Jong Sup

    1982-01-01

    Pulmonary edema is a rare adverse reaction to the iodinated contrast medium. Complaining of huge abdominal mass, a 52 years old female was admitted to the Hangang Sungsim Hospital. On physical examination, the patient appeared to be healthy. She had stable vital signs, i.e. BP: 120/80 mmHg, pulse rate: 80/min.etc. An adult head sized mass was palpated in the left mid and lower abdomen. Otherwise nonspecific. On laboratory studies the positive findings were 8-10 WBC/HPF in urine, 25.6 mg/dl for BUN and PVC in EKG. It was negative for urine protein, serum creatinline and liver function test. We injected 100 ml and 30 ml of Urografin 60 through the abdominal aorta dividing 3 times and major branches of the abdominal aorta, respectively. Immediately after complicating angiography, interstitial pulmonary edema was found, showing blurring of the vascular margins, perivascular haziness and thickening of the interlobular septal lines in the both lower lung fields. The blood pressure was dropped to 80/60 mmHg, but pulse rate was normal. She did not complain of dyspnea, and cyanosis was not developed. The urine volume was normally maintained. She was treated for pulmonary edema, which was completely absorbed after 20 hours. And the blood pressure was also normalized. We have experienced a case of pulmonary edema developed after intraarterial injection of the iodinated contrast medium without underlying cardiac, renal and hepatic problems, and reviewed the literatures on mechanisms of pulmonary edema caused by intravascular injection of the iodinated contrast materials

  6. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.

    2005-01-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  7. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [Copenhagen University Hospital, Herlev (Denmark). Department of Diagnostic Radiology; Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield Teaching Hospitals NHS Trust, Sheffield (United Kingdom)

    2005-04-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  8. Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Qu, Mingliang; Duan, Xinhui; Takahashi, Naoki; Kawashima, Akira; Leng, Shuai; McCollough, Cynthia H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2012-12-15

    To develop a dual-energy CT (DECT) method for differentiating uric acid (UA) from non-UA stones in the presence of iodinated contrast medium. Thirty UA and 45 non-UA stones were selected after infra-red spectroscopic analysis and independently placed in a 1.5-ml vial, which was filled first with saline and then with increasing concentrations of iodine. For each condition, tubes were put in a 35-cm water phantom and examined using a dual-source CT system at 100 and 140 kV. Virtual unenhanced images created from CT data sets of the stones in iodine-containing solutions provided position and volume information. This map was used to calculate a CT number ratio to differentiate stone type. A region-growing method was developed to improve the ability to differentiate between UA and non-UA stones with iodinated contrast medium. The sensitivity for detecting UA stones was 100 % for unenhanced images but fell to 18 % with 20 mgI/ml iodine solution and 0 % for higher concentrations. With region growing, the sensitivity for detecting UA stones was increased to 100 %, 82 %, 57 %, 50 % and 21 % for iodine solutions of 20, 40, 60, 80 and 100 mgI/ml. The region-growing method improves differentiation of UA from non-UA stones on contrast-enhanced DECT urograms. (orig.)

  9. Effects of high iodine doses given parenterally as contrast medium on parameter of the pro/antioxidative balance

    International Nuclear Information System (INIS)

    Winkler, R.; Griebenow, S.; Scheidleder, B.; Bailer, H.

    2002-01-01

    The aim of this study was to investigate effects of high iodine doses given parenterally as contrast medium on parameters of lipid status and thyroid hormone status as well as on parameters of the pro/antioxidative balance of spa patients. 29 patients with a comparable indication who had to undergo an angiography were chosen. The blood parameters of these patients were determined before and after the angiographic treatment. No provable changes of the thyroid parameters f-T 3 , f-T 4 and TSH were found after the angiography. In case of enzyme activities, the protective enzymes SOD and GSHPX showed no changes, while the concentrations of peroxides and MDA were increased significantly. Corresponding to this, the total antioxidative status and the vitamin E level decreased significantly. Altogether these results stand for a moderate deterioration of the antioxidative protective potential by the highly iodine containing contrast medium. (author)

  10. Transient angioedema of small bowel secondary to intravenous iodinated contrast medium

    Directory of Open Access Journals (Sweden)

    Kirankumar N Kulkarni

    2014-01-01

    Full Text Available We report the clinical details and imaging findings of a case of transient angioedema of the small bowel following intravenous administration of non-ionic iodinated contrast material in a 17 year old female with no predisposing risk factors. Findings included long segment, symmetric, circumferential, low-density, bowel wall thickening involving the duodenum, jejunum, and most of the ileum on computed tomography scan obtained at 7 min following intravenous contrast material injection. This entity is self-limiting with a favourable clinical outcome and requires no specific treatment but only aggressive clinical monitoring.

  11. Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: Comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate

    International Nuclear Information System (INIS)

    Kishimoto, Miori; Doi, Shoko; Shimizu, Junichiro; Lee, Ki-Ja; Iwasaki, Toshiroh; Miyake, Yoh-Ichi; Yamada, Kazutaka

    2010-01-01

    Purpose: To evaluate the influence of osmolarity of iodinated contrast media and saline flush on the contrast effect in thoracic computed tomography angiography (CTA) at an identical iodine delivery rate (IDR). Materials and methods: Seven beagles were used in a cross-over experiment. The contrast media used were iohexol 350 mgI/ml (IOH350; osmolarity 844 mmol/kg) and iodixanol 320 mgI/ml (IDX320; osmolarity 290 mmol/kg). Each contrast medium was administered to groups with and without saline flush at 40.0 mgI/kg/s for all experiments. Dynamic CT scanning was performed at the ninth thoracic vertebra level. The peak value, area under the curve (AUC), and time to peak (TTP) were calculated from the time attenuation curves of the pulmonary artery and aorta. Results: There was no significant difference between IOH350 and IDX320 with or without saline flush in the peak values for the pulmonary artery and aorta. AUC was significantly higher in groups with saline flush for both contrast media and arteries (p < 0.05) with no significant difference between contrast media. TTP was significantly longer in groups with saline flush than without saline flush for both contrast media and arteries (p < 0.05), with no significant difference between contrast media. Conclusions: There were no significant differences in the contrast effects of monomeric IOH350 and dimeric IDX320 in thoracic CTA when used at an identical IDR. Moreover, saline flush prolonged the peak duration at 600 mgI/kg.

  12. Potentials and limitations of low-concentration contrast medium (150 mg iodine/ml) in CT pulmonary angiography

    International Nuclear Information System (INIS)

    Radon, M.R.; Kaduthodil, M.J.; Jagdish, J.; Matthews, S.; Hill, C.; Bull, M.J.; Morcos, S.K.

    2011-01-01

    Aim: To assess the feasibility of producing diagnostic multidetector computed tomography (MDCT) pulmonary angiography with low iodine concentration contrast media (150 mg iodine/ml) in patients with suspected acute pulmonary embolism. Materials and methods: Ninety-five randomized patients underwent MDCT (64 row) pulmonary angiography with 100 ml iopromide either at low concentration (LC) of 150 mg iodine/ml (n = 45) or high concentration (HC) of 300 mg iodine/ml (n = 50), delivered at the rate of 5 ml/s via a power injector. Two experienced radiologists, blinded to the concentration used, subjectively assessed the diagnostic quality and confidence using a four-point scale [1 = poor (not diagnostic), 2 = satisfactory, 3 = good, 4 = excellent]. Attenuation values (in HU) were measured in the main proximal branches of the pulmonary arteries. Results: The median diagnostic quality score for both observers was 3.5 (interquartile range 3-4) in the HC group and 2.5 (interquartile range 1.5-3) in the LC group (p < 0.01). The median diagnostic confidence score for both observers was 4 (interquartile range 3-4) in the HC group and 3 (interquartile range 1.5-4) in the LC group (p < 0.01). Both observers rated examinations as diagnostic in 69% of cases in the LC group, compared with 96% of cases in the HC group. Good interobserver agreement was found in both groups (K value 0.72 in the LC group and 0.73 in the HC). Obesity, poor scan timing, and dilution by venous return of non-opacified blood were the main reasons for a reduction in diagnostic quality of examinations in the LC group. Conclusion: Despite a 50% reduction of contrast medium dose in comparison to the standard technique, 150 mg iodine/ml can produce diagnostic MDCT pulmonary angiogram studies in the absence of obesity or high cardiac output and hyper-dynamic pulmonary circulation. Reducing the dose of contrast media would minimize the risk of contrast nephropathy in patients at risk of this complication

  13. Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomography

    International Nuclear Information System (INIS)

    Nagamoto, Masashi; Gomi, Tatsuya; Terada, Hitoshi; Terada, Shigehiko; Kohda, Eiichi

    2006-01-01

    The aim of this prospective study was to evaluate and compare acute adverse reactions between contrast medium containing moderate and high concentrations of iodine in patients undergoing computed tomography (CT). A total of 945 patients undergoing enhanced CT were randomly assigned to receive one of two doses of contrast medium. We then prospectively investigated the incidence of adverse reactions. Iopamidol was used as the contrast medium, with a high concentration of 370 mgI/ml and a moderate concentration of 300 mgI/ml. The frequency of adverse reactions, such as pain at the injection site and heat sensation, were determined. Acute adverse reactions were observed in 2.4% (11/458) of the moderate-concentration group compared to 3.11% (15/482) of the high-concentration group; there was no significant difference in incidence between the two groups. Most adverse reactions were mild, and there was no significant difference in severity. One patient in the high-concentration group was seen to have a moderate adverse reaction. No correlation existed between the incidence of adverse reactions and patient characteristics such as sex, age, weight, flow amount, and flow rate. The incidence of pain was not significantly different between the two groups. In contrast, the incidence of heat sensation was significantly higher in the high-concentration group. The incidence and severity of acute adverse reactions were not significantly different between the two groups, and there were no severe adverse reactions in either group. (author)

  14. CT contrasting theory. Effects of the concentration, volume and infusion rate of iodine contrast medium on TDC

    International Nuclear Information System (INIS)

    Yamachi, Jun

    2007-01-01

    This study was performed to evaluate the effects in the title on TDC (time-density curve) using a phantom. CT machine used was Toshiba Aquilion Multi 64, TDC phantom was the product of Nemoto-Kyorindo Co., and the contrast medium was Eisai iomeprol, in syringe-sealed formulations of 300 and 350 mg I/mL. The medium was infused at 1-5 mL/sec in the phantom equivalent to body weight of 78 kg (total water volume=1 min circulation=6,000 mL, 800 mL/heart) to obtain 30 TDCs. Evaluated were the relationships of the infusion rate (mL/sec), volume (mL) or time (sec) with TDC parameters of the detection time of the medium, slope, time to reach the maximum CT value, the maximum CT value, time to keep the CT concentration and its actual concentration. Results revealed that, regardless to the difference of formulations of the contrast medium, TDC with high reproducibility can be obtainable by making the infusion rate of I per unit time and body weight (mgI/sec/kg) constant when the infusion time is made identical for CT of the same diagnostic purpose. (R.T.)

  15. Current iodinated contrast media

    International Nuclear Information System (INIS)

    Stacul, F.

    2001-01-01

    The number of scientific papers on iodinated contrast media is declining. Indeed, comparative trials between high-osmolality and low-osmolality agents largely showed the higher safety and tolerability of the latter, and this is no longer a matter of discussion. Only financial constraints could prevent a total conversion to low-osmolality agents. Research comparing low-osmolality (nonionic monomers, ionic dimer) and iso-osmolality contrast media (nonionic dimers) are still ongoing. Both classes of nonionic compounds proved safer than the ionic dimer. The relative merits of nonionic monomers and nonionic dimers are a matter for debate, and criteria for a selective use of different agents for different procedures could be discussed. (orig.)

  16. Iodinated contrast media nephrotoxicity

    International Nuclear Information System (INIS)

    Meyrier, A.

    1994-01-01

    In the late seventies, iodinated contrast agents (ICA) were considered to be a major cause of acute iatrogenic renal failure. Over the last decade new contrast agents have been synthesized, nonionic and less hyperosmolar. The incidence of acute renal failure due to ICAs, varies from 3.7 to 70% of cases according to the series, with an average figure of 10.2%. The pathophysiology of ICA nephrotoxicity was mainly studied in laboratory animal models. Three main factors are involved in an inducing ICA-mediated decrease in glomerular filtration rate: reduction of the renal plasma flow, a direct cytotoxic effect on renal tubular cells and erythrocyte alteration leading to intra-renal sludge. Excluding dysglobulinemias with urinary excretion of immunoglobulin light chains, which represent a special case of maximum nephrotoxicity, 4 main risk factors of renal toxicity have been identified in nondiabetic subjects: previous renal failure with serum creatinine levels greater than 140 μmol per liter, extracellular dehydration, age over 60 and use of high doses of ICA and/or repeated ICA injections before serum creatinine levels return to baseline. Preventive measures for avoiding ICA nephrotoxicity are threefold: maintain or restore adequate hydration with saline infusion, stop NSAID treatment several days before ICA administration, and allow a 5 day interval before repeating contrast media injections. New, nonionic and moderately hyperosmolar contrast agents appear to be much less nephrotoxic than conventional ICAs in laboratory animals and in high-risk patients. It is advisable to select such contrast media for investigating high-risk patients. This approach was recently substantiated in well designed, randomized clinical studies which included more than 2 000 patients. (author)

  17. Effect of contrast media iodine concentration on bolus tracking

    International Nuclear Information System (INIS)

    Ishihara, Toshihiro; Hayashi, Takayuki; Nakaya, Yoshihiro; Naoi, Kuniji; Ikeno, Naoya; Kobayashi, Tatsushi; Satake, Mitsuo

    2006-01-01

    Computer-assisted bolus tracking has been confirmed to be a useful technique in computed tomography (CT) imaging and allows images to be captured with automated timing. The inflow of the contrast medium is monitored, and when the contrast medium reaches a predetermined level, CT image capture starts automatically. However, it has been shown that the preset threshold value of contrast medium is affected by its iodine concentration, which causes variations in image capture times. Greater speed in current multislice CT imaging requires that medical technicians pay more attention to setting the timing of image capture during venous examinations by taking into account the iodine concentration in contrast media. (author)

  18. Contrast induced hyperthyroidism due to iodine excess

    OpenAIRE

    Mushtaq, Usman; Price, Timothy; Laddipeerla, Narsing; Townsend, Amanda; Broadbridge, Vy

    2009-01-01

    Iodine induced hyperthyroidism is a thyrotoxic condition caused by exposure to excessive iodine. Historically this type of hyperthyroidism has been described in areas of iodine deficiency. With advances in medicine, iodine induced hyperthyroidism has been observed following the use of drugs containing iodine—for example, amiodarone, and contrast agents used in radiological imaging. In elderly patients it is frequently difficult to diagnose and control contrast related hyperthyroidism, as most...

  19. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  20. Monochromatic Spectral Computed Tomography with Low Iodine Concentration Contrast Medium in a Rabbit VX2 Liver Model:: Investigation of Image Quality and Detection Rate.

    Science.gov (United States)

    Zhou, Yue; Xu, Han; Hou, Ping; Dong, Jun Q; Wang, Ming Y; Gao, Jian B

    2016-04-01

    This study aimed to validate the feasibility of using virtual monochromatic spectral computed tomography (CT) with isotonic low iodine concentration contrast medium for VX2 hepatic tumors. Sixty New Zealand white rabbits with implanted VX2 hepatic tumors underwent two-phase contrast-enhanced spectral CT imaging on the 14th day after tumor implantation. They were randomly divided into groups A, B, and C, with 20 rabbits each (group A: 270 mg I/mL, monochromatic spectral images; group B: 370 mg I/mL, conventional 120 kVp images, 100% filtered back projection [FBP]; group C: 270 mg I/mL, conventional 120 kVp images, 100% FBP). Group A was further divided into two subgroups (subgroup A1: 100% FBP; subgroup A2: 50% FBP + 50% adaptive statistical iterative reconstruction). Objective evaluation (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and image noise), subjective rating score (image noise score, anatomical details score, overall image quality score, and lesion conspicuity score), CT dose index volume, and dose length product were compared between groups during two-phase contrast enhancement. The detection rates of the four groups were calculated as percentages. Image noise (SNR and CNR) among the four groups was statistically significant (P noise in group A2 was lower than in group A1, but higher than that in groups B and C (P noise score of group A2 was higher than that of the other three groups. In terms of the anatomic details score, the overall image quality score, and the lesion conspicuity score, the images of group A2 were superior to that of groups A1 and C. For hepatic tumor diameters more than or equal to 1.0 cm and less than 3.0 cm, group A achieved a higher detection rate than groups B and C. The CT dose index volume, dose length product, and effective dose in group A were significantly lower than that in groups B and C (P noise, increase detection rate for small tumors, and decrease radiation dose and iodine load in

  1. Roentgen contrast medium

    International Nuclear Information System (INIS)

    Tamborski, C.

    1989-01-01

    The patent deals with a roentgen contrast medium containing a perfluorinebrominealkylether of the formula C m F 2m+1 OC n F 2n Br dispersed in water, preferentially in the presence of a non-ionic dispersing agent such as a fluorinated amidoaminoxide. 2 tabs

  2. Fixed drug eruption induced by an iodinated non-ionic X-ray contrast medium: a practical approach to identify the causative agent and to prevent its recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Ingrid; Block, Wolfgang; Schild, Hans H. [University of Bonn, Department of Radiology, Bonn (Germany); Medina, Jesus; Prieto, Pilar [JUSTESA IMAGEN SA, Biological R and D Department, Madrid (Spain)

    2007-02-15

    We describe the case of a 61-year-old physician who developed a fixed drug eruption (FDE) after i.v. administration of a non-ionic monomeric iodinated X-ray contrast medium (CM) (iopromide). During CM injection, a sensation of heat occurred, which was most intense in the right inguinal region. Four hours later, the FDE arose with a red macule of approximately 2 cm in diameter covering a dermal infiltration in the right inguinal region, and enlarged up to a final size of 15 x 8 cm, accompanied by a burning sensation. The patient's history revealed a similar reaction in the same localization and of the same clinical appearance after CM injection 1 year before. Patch testing 4 months later revealed positive reactions to iomeprol and iohexol. Iopamidol injection for another CT examination 23 months later was well tolerated. Based on these results, we suggest patch testing after CM-induced FDE, which could help to select a CM for future CT examinations. Late onset of adverse CM reactions may manifest as FDE. Patch testing within the previous skin reaction area is the diagnostic tool that should be used to confirm the suspected agent, possible cross-reacting agents and well-tolerated agents. (orig.)

  3. Fixed drug eruption induced by an iodinated non-ionic X-ray contrast medium: a practical approach to identify the causative agent and to prevent its recurrence

    International Nuclear Information System (INIS)

    Boehm, Ingrid; Block, Wolfgang; Schild, Hans H.; Medina, Jesus; Prieto, Pilar

    2007-01-01

    We describe the case of a 61-year-old physician who developed a fixed drug eruption (FDE) after i.v. administration of a non-ionic monomeric iodinated X-ray contrast medium (CM) (iopromide). During CM injection, a sensation of heat occurred, which was most intense in the right inguinal region. Four hours later, the FDE arose with a red macule of approximately 2 cm in diameter covering a dermal infiltration in the right inguinal region, and enlarged up to a final size of 15 x 8 cm, accompanied by a burning sensation. The patient's history revealed a similar reaction in the same localization and of the same clinical appearance after CM injection 1 year before. Patch testing 4 months later revealed positive reactions to iomeprol and iohexol. Iopamidol injection for another CT examination 23 months later was well tolerated. Based on these results, we suggest patch testing after CM-induced FDE, which could help to select a CM for future CT examinations. Late onset of adverse CM reactions may manifest as FDE. Patch testing within the previous skin reaction area is the diagnostic tool that should be used to confirm the suspected agent, possible cross-reacting agents and well-tolerated agents. (orig.)

  4. Quantitative contrast-enhanced mammography for contrast medium kinetics studies

    Science.gov (United States)

    Arvanitis, C. D.; Speller, R.

    2009-10-01

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm-2 has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm-2 within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  5. Influence of tri-iodinated water soluble X-ray contrast medium for uro, angio and cholangiography on the plasmic coagulation system

    International Nuclear Information System (INIS)

    Kaps, H.P.

    1982-01-01

    In-vitro coagulation studies comprising overall and individual factor determinations were carried out with the aim of clarifying the nature of unforeseen incidents arising from the use of contrast media in X-ray diagnosis. In all tests a reproducible, dose-dependent, exponential coagulation inhibition was obtained, and resulted in complete inhibition at higher dose levels. This effect occurred by a factor of ten earlier, on average, with iodine ipamide, representative of liver passage bile CM, compared to uro, and angiographic CM diatrozoate and iodine thalamate used for kidney passage. Hepatotrophic CM act initially hypercoagulative at low dises through activation of the thrombin coagulase complex; later inhibition of coagulation sets in through direct fixation on functional proteins and their subsequent denaturation. A discussion is given of the importance of direct physico-chemical toxicity, histamine liberation reactions and cellular reactions, and the controversial role of the complement system is presented. (orig./MG) [de

  6. Incompatibility of Contrast Medium and Trisodium Citrate

    International Nuclear Information System (INIS)

    Delcour, Christian; Bruninx, Guy

    2013-01-01

    To test the compatibility of trisodium citrate, a catheter lock solution, with iodinated contrast medium. Iohexol, iobitridol, iodixanol, ioxaglate, ioxithalamate, iomeprol, and iopromide were tested. In all tests, 2 ml of contrast medium were mixed with 2 ml of trisodium citrate solution. Iodixanol and ioxaglate provoked a highly viscous gluelike precipitation when mixed with trisodium citrate. A brief transient precipitate was observed with iohexol, iomeprol, and ioxithalamate. Permanent precipitation occurred with iobitridol and iopromide. One must be aware of the potential for precipitation when contrast medium is mixed with trisodium citrate solution. Before trisodium citrate solution is injected, the catheter should be thoroughly flushed with saline if a contrast medium has previously been injected through it.

  7. Anaphylactoid reactions after iodinated contrast media

    International Nuclear Information System (INIS)

    Strejcek, J.; Sehr, A.

    1987-01-01

    A survey is presented of data published in the literature on the incidence of undesirable and especially anaphylactoid reactions to intravenously administered iodinated contrast media used in radiodiagnosis, this with regard to age, sex, allergy in the patient's history, previously administered contrast media, possible previous reaction. A detailed description is presented of the assumed mechanisms of these reactions. There does not exist any reliable premedication. It is always indispensable to consider the indications of the examination using iodinated contrast agents and the possibilities of immediate and qualified resuscitation. (author). 2 tabs., 36 refs

  8. Physical experiments on the utility of non-iodine-containing contrast media

    International Nuclear Information System (INIS)

    Kirschner, H.; Burmester, U.; Stringaris, K.; Jentsch, F.

    1979-01-01

    Because of the excellent ability of the CT scanner in analyzing absorption, the use of non-iodine-containing contrast media will be discussed. Experimental studies of the chemical elements with the atomic number Z = 1-83 with a scan tension of 120 kV were made to determine how many atoms of a given element are necessary to replace one iodine atom in an iodine-containing contrast medium, whereby the same contrast enhancement in the scan picture as with the iodine-containing contrast medium is produced. (orig.) 891 ORU/orig. 892 MB [de

  9. Late adverse reactions to intravascular iodinated contrast media

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.

    2003-01-01

    Late adverse reactions to intravascular iodinated contrast media are defined as reactions occurring 1 h to 1 week after contrast medium injection. They have received increasing interest over the past decade, but their prevalence remains uncertain and their pathophysiology is not fully understood. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and to issue guidelines. An extensive literature search was carried out and summarized in a report. Based on the available information, simple guidelines have been drawn up. The report and guidelines were discussed at the 8th European Symposium on Urogenital Radiology in Genoa. Late adverse reactions after intravascular iodinated contrast medium include symptoms such as nausea, vomiting, headache, itching, skin rash, musculoskeletal pain, and fever. A significant proportion of these reactions is unrelated to the contrast medium; however, allergy-like skin reactions are well-documented side effects of contrast media with an incidence of approximately 2%. Late reactions appear to be commoner after non-ionic dimers. The majority of late skin reactions after contrast medium exposure are probably T-cell-mediated allergic reactions. Patients at increased risk of late skin reactions are those with a history of previous contrast medium reaction and those on interleukin-2 treatment. Most skin reactions are self-limiting and resolve within a week. Management is symptomatic and similar to the management of other drug-induced skin reactions. (orig.)

  10. Nonimmediate hypersensitivity reactions to iodinated contrast media.

    Science.gov (United States)

    Gómez, Enrique; Ariza, Adriana; Blanca-López, Natalia; Torres, Maria J

    2013-08-01

    To provide a detailed analysis of the latest findings on the mechanisms underlying the nonimmediate reactions to iodinated contrast media and comment on the recent advances in diagnosis, focusing on the roles of the skin test, drug provocation test (DPT), and lymphocyte transformation test (LTT). Several studies have reported new findings supporting an important role for T-lymphocytes in the nonimmediate reactions to iodinated contrast media. The LTT has been used as an in-vitro tool for diagnosis, but with variable results. However, the inclusion of autologous monocyte-derived dendritic cells as professional antigen-presenting cells has improved the sensitivity of this test. Regarding in-vivo diagnosis, although skin testing has been routine, it has now been shown that its sensitivity and negative predictive value are low. Recent studies have demonstrated that the DPT is a well tolerated and useful procedure that is necessary to confirm the diagnosis of nonimmediate hypersensitivity reactions to iodinated contrast media. Nonimmediate reactions to contrast media are usually T-cell mediated. Diagnosis is based on skin testing, although its sensitivity and negative predictive value are not optimal. Consequently, drug provocation testing is often needed to confirm the diagnosis and also to seek alternative contrast media that can be tolerated.

  11. Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hiroto; Okada, Masahiro; Hyodo, Tomoko; Hidaka, Syojiro; Kagawa, Yuki; Matsuki, Mitsuru; Tsurusaki, Masakatsu; Murakami, Takamichi, E-mail: murakami@med.kindai.ac.jp

    2014-04-15

    Purpose: To investigate whether low-dose dynamic CT of the liver with iterative reconstruction can reduce both the radiation dose and the amount of contrast medium. Materials and methods: This study was approved by our institutional review board. 113 patients were randomly assigned to one of two groups. Group A/group B (fifty-eight/fifty-five patients) underwent liver dynamic CT at 120/100 kV, with 0/40% adaptive statistical iterative reconstruction (ASIR), with a contrast dose of 600/480 mg I/kg, respectively. Radiation exposure was estimated based on the manufacturer's phantom data. The enhancement value of the hepatic parenchyma, vessels and the tumor-to-liver contrast of hepatocellular carcinomas (HCCs) were compared between two groups. Two readers independently assessed the CT images of the hepatic parenchyma and HCCs. Results: The mean CT dose indices: 6.38/4.04 mGy, the dose-length products: 194.54/124.57 mGy cm, for group A/group B. The mean enhancement value of the hepatic parenchyma and the tumor-to-liver contrast of HCCs with diameters greater than 1 cm in the post-contrast all phases did not differ significantly between two groups (P > 0.05). The enhancement values of vessels in group B were significantly higher than that in group A in the delayed phases (P < 0.05). Two reader's confidence levels for the hepatic parenchyma in the delayed phases and HCCs did not differ significantly between the groups (P > 0.05). Conclusions: Low-dose dynamic CT with ASIR can reduce both the radiation dose and the amount of contrast medium without image quality degradation, compared to conventional dynamic CT without ASIR.

  12. Neurotoxicity of iodinated radiological contrast media

    International Nuclear Information System (INIS)

    Araujo Pinheiro, R.S. de

    1988-01-01

    We studied during the last ten years the neurotoxicity of artificial iodinated contrast media, with prospective clinical and experimental protocols. The experimental investigation in animals aimed to understand the relationship between the intracarotid injection, the subarachnoid application and the integrity of the blood-brain barrier function. The electro physiologic disturbances and the morphologic observation of pial circulation support the evidence that iodinated artificial contrast media induces significant alterations in brain metabolism and in the autoregulation of the blood flow of the encephalon. Even if many of such phenomena may not be apparent at the clinical level, we supposed that they are always present and that their clinical exteriorization is prevented by the immediate and effective action of homeostatic mechanisms. (author)

  13. Risk of application of contrast medium in computed tomography

    International Nuclear Information System (INIS)

    Wende, S.; Speck, U.; Schering A.G., Berlin

    1981-01-01

    The paper deals with the risk associated with the application of contrast medium in CT. The risk is to be seen in intolerance reactions, such as allergic or circulatory reactions and neurotoxic side-effects. In this paper the problems of renal failure caused by the injection of contrast medium are given special attention. Furthermore an iodine-induced hyperthyreosis might result. Especially the possible disturbance of the kidney function means that contrast medium should not be applied arbitrarily and that the examination should be done only by experienced staff. Furthermore the indication for the application of contrast medium in CT should be strictly qualified. (orig.) [de

  14. Risk of application of contrast medium in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wende, S.; Speck, U.

    1981-06-01

    The paper deals with the risk associated with the application of contrast medium in CT. The risk is to be seen in intolerance reactions, such as allergic or circulatory reactions and neurotoxic side-effects. In this paper the problems of renal failure caused by the injection of contrast medium are given special attention. Furthermore an iodine-induced hyperthyreosis might result. Especially the possible disturbance of the kidney function means that contrast medium should not be applied arbitrarily and that the examination should be done only by experienced staff. Furthermore the indication for the application of contrast medium in CT should be strictly qualified.

  15. Effect of iodinated contrast media on thyroid: a brief review

    Directory of Open Access Journals (Sweden)

    Şerife Mehlika Kuşkonmaz

    2016-04-01

    Full Text Available In parallel to the increased use of computed tomography, iodinated contrast agents are increasingly becoming a source of excess iodide. Iodinated contrast agents may induce thyroid dysfunction in exposed patients, especially in the presence of an underlying thyroid disease. Thus, an ordinary dose of the contrast used for the imaging, can induce hyper or hypothyroidism in a patient with subtle thyroid disease. This review will briefly discuss the physiology of iodine and the clinical evaluation of iodine induced thyroid dysfunction.

  16. Anaphylactic reaction to iodinated contrast media. Review the relevant loterature

    International Nuclear Information System (INIS)

    Kuwashima, Shigeko; Kitajima, Kazuhiro; Kohno, Tatsuo; Kaji, Yasushi; Takahashi, Tetuya; Seki, Masaya; Sakamoto, Tomoyuki

    2007-01-01

    Recently, iodinated contrast media are necessary for CT examinations and they occupy an important position in the radiological diagnosis. Nonionic contrast media significantly reduce the prevalence of all degree of adverse reaction to contrast media rather than ionic contrast media. So, generally, iodinated contrast media are safe and widely used, but adverse reaction after intravenous iodinated contrast media are not uncommon. Severe and potentially life-threatening reaction occur by using the iodinated contrast media practically. Patients at risk must be identified before the contrast media study, and all possible measures must be taken to deal effectively with spontaneous anaphylactic reactions. We report three cases of anaphylactic reactions by iodinated contrast media on CT. (author)

  17. A Review: Radiographic Iodinated Contrast Media-Induced Thyroid Dysfunction

    Science.gov (United States)

    Leung, Angela M.; Braverman, Lewis E.; Brent, Gregory A.; Pearce, Elizabeth N.

    2015-01-01

    Context: Thyroid hormone production is dependent on adequate iodine intake. Excess iodine is generally well-tolerated, but thyroid dysfunction can occur in susceptible individuals after excess iodine exposure. Radiological iodinated contrast media represent an increasingly common source of excess iodine. Objective: This review will discuss the thyroidal response after acute exposure to excess iodine; contrast iodine-induced thyroid dysfunction; risks of iodine-induced thyroid dysfunction in vulnerable populations, such as the fetus, neonate, and patients with impaired renal function; and recommendations for the assessment and treatment of contrast iodine-induced thyroid dysfunction. Methods: Data for this review were identified by searching PubMed, Google Scholar, and references from relevant articles from 1948 to 2014. Conclusions: With the increase in the use of computed tomography scans in the United States, there is increasing risk of contrast-induced thyroid dysfunction. Patients at risk of developing iodine-induced thyroid dysfunction should be closely monitored after receiving iodinated contrast media and should be treated as needed. PMID:25375985

  18. The use of iodinated and gadolinium contrast media during pregnancy and lactation

    Energy Technology Data Exchange (ETDEWEB)

    Webb, Judith A.W. [St. Bartholomew' s Hospital, Department of Diagnostic Imaging, London (United Kingdom); Thomsen, Henrik S. [Copenhagen University Hospital at Herlev, Department of Diagnostic Radiology 54E2, Herlev (Denmark); Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield (United Kingdom)

    2005-06-01

    The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents. (orig.)

  19. The use of iodinated and gadolinium contrast media during pregnancy and lactation

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Thomsen, Henrik S.; Morcos, Sameh K.

    2005-01-01

    The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents. (orig.)

  20. Iodinated Contrast Media and the Alleged "Iodine Allergy": An Inexact Diagnosis Leading to Inferior Radiologic Management and Adverse Drug Reactions.

    Science.gov (United States)

    Böhm, Ingrid; Nairz, Knud; Morelli, John N; Keller, Patricia Silva Hasembank; Heverhagen, Johannes T

    2017-04-01

    Purpose  To test the hypothesis that the incomplete diagnosis "iodine allergy" is a possibly dangerous concept for patients under routine radiologic conditions. Materials and Methods  300 patients with a history of an "iodine allergy" were retrospectively screened and compared with two age-, sex-, and procedure-matched groups of patients either diagnosed with a nonspecific "iodine contrast medium (ICM) allergy" or an allergy to a specific ICM agent. For all groups, the clinical symptoms of the most recent past adverse drug reaction (ADR), prophylactic actions taken for subsequent imaging, and ultimate outcome were recorded and analyzed. Results  The diagnosis "iodine allergy" was not otherwise specified in 84.3 % patients. For this group, in most cases, the symptoms of the previous ADRs were not documented. In contrast, the type of ADR was undocumented in only a minority of patients in the comparison groups. In the group of patients with an "iodine allergy" the percentage of unenhanced CT scans was greater than within the other two groups (36.7 % vs. 28.7 %/18.6 %). ADRs following prophylactic measures were only observed in the "iodine allergy" group (OR of 9.24 95 % CI 1.16 - 73.45; p contrast media containing covalently bound iodine.. · There is a clear correlation between the exactness of the diagnosis - from the alleged "iodine allergy" to "contrast media allergy" to naming the exact culprit CM - and the quality of documentation of the symptoms.. · Management of patients diagnosed with "iodine allergy" was associated with uncertainty leading to unenhanced scans and sometimes unnecessary prophylactic actions.. · The term "iodine allergy" should be omitted, because it is potentially dangerous and can decrease the quality of radiology exams.. Citation Format · Böhm Ingrid, Nairz Knud, Morelli John N et al. Iodinated Contrast Media and the Alleged "Iodine Allergy": An Inexact Diagnosis Leading to Inferior Radiologic Management and

  1. Urinary Iodine Clearance following Iodinated Contrast Administration: A Comparison of Euthyroid and Postthyroidectomy Subjects

    Directory of Open Access Journals (Sweden)

    Janice D. Ho

    2014-01-01

    Full Text Available Purpose. To compare iodine clearance following iodinated contrast administration in thyroidectomised thyroid cancer patients and euthyroid individuals. Methods. A convenience population (6 thyroidectomised thyroid cancer patients and 7 euthyroid controls was drawn from patients referred for iodinated contrast-enhanced computed tomography (CT studies. Subjects had sequential urine samples collected up to 6 months (50 samples from the thyroidectomised and 63 samples from the euthyroid groups. t-tests and generalised estimating equations (GEE were used to test for group differences in urinary iodine creatinine ratios. Results. Groups had similar urinary iodine creatinine ratios at baseline, with a large increase 2 weeks following iodinated contrast (P=0.005. Both groups had a return of urinary iodine creatinine ratios to baseline by 4 weeks, with no significant group differences overall or at any time point. Conclusions. Thyroidectomised patients did not have a significantly different urinary iodine clearance than euthyroid individuals following administration of iodinated contrast. Both had a return of urinary iodine creatinine ratios to baseline within 4 weeks.

  2. Iodinated contrast media nephrotoxicity. Nephrotoxicite des produits de contraste iodes

    Energy Technology Data Exchange (ETDEWEB)

    Meyrier, A. (Hopital Avicenne, 93 - Bobigny (France))

    1994-01-01

    In the late seventies, iodinated contrast agents (ICA) were considered to be a major cause of acute iatrogenic renal failure. Over the last decade new contrast agents have been synthesized, nonionic and less hyperosmolar. The incidence of acute renal failure due to ICAs, varies from 3.7 to 70% of cases according to the series, with an average figure of 10.2%. The pathophysiology of ICA nephrotoxicity was mainly studied in laboratory animal models. Three main factors are involved in an inducing ICA-mediated decrease in glomerular filtration rate: reduction of the renal plasma flow, a direct cytotoxic effect on renal tubular cells and erythrocyte alteration leading to intra-renal sludge. Excluding dysglobulinemias with urinary excretion of immunoglobulin light chains, which represent a special case of maximum nephrotoxicity, 4 main risk factors of renal toxicity have been identified in nondiabetic subjects: previous renal failure with serum creatinine levels greater than 140 [mu]mol per liter, extracellular dehydration, age over 60 and use of high doses of ICA and/or repeated ICA injections before serum creatinine levels return to baseline. Preventive measures for avoiding ICA nephrotoxicity are threefold: maintain or restore adequate hydration with saline infusion, stop NSAID treatment several days before ICA administration, and allow a 5 day interval before repeating contrast media injections. New, nonionic and moderately hyperosmolar contrast agents appear to be much less nephrotoxic than conventional ICAs in laboratory animals and in high-risk patients. It is advisable to select such contrast media for investigating high-risk patients. This approach was recently substantiated in well designed, randomized clinical studies which included more than 2 000 patients. (author).

  3. Iodine-based contrast media, multiple myeloma and monoclonal gammopathies: literature review and ESUR Contrast Media Safety Committee guidelines.

    Science.gov (United States)

    Stacul, Fulvio; Bertolotto, Michele; Thomsen, Henrik S; Pozzato, Gabriele; Ugolini, Donatella; Bellin, Marie-France; Bongartz, Georg; Clement, Olivier; Heinz-Peer, Gertraud; van der Molen, Aart; Reimer, Peter; Webb, Judith A W

    2018-02-01

    Many radiologists and clinicians still consider multiple myeloma (MM) and monoclonal gammopathies (MG) a contraindication for using iodine-based contrast media. The ESUR Contrast Media Safety Committee performed a systematic review of the incidence of post-contrast acute kidney injury (PC-AKI) in these patients. A systematic search in Medline and Scopus databases was performed for renal function deterioration studies in patients with MM or MG following administration of iodine-based contrast media. Data collection and analysis were performed according to the PRISMA statement 2009. Eligibility criteria and methods of analysis were specified in advance. Cohort and case-control studies reporting changes in renal function were included. Thirteen studies were selected that reported 824 iodine-based contrast medium administrations in 642 patients with MM or MG, in which 12 unconfounded cases of PC-AKI were found (1.6 %). The majority of patients had intravenous urography with high osmolality ionic contrast media after preparatory dehydration and purgation. MM and MG alone are not risk factors for PC-AKI. However, the risk of PC-AKI may become significant in dehydrated patients with impaired renal function. Hypercalcaemia may increase the risk of kidney damage, and should be corrected before contrast medium administration. Assessment for Bence-Jones proteinuria is not necessary. • Monoclonal gammopathies including multiple myeloma are a large spectrum of disorders. • In monoclonal gammopathy with normal renal function, PC-AKI risk is not increased. • Renal function is often reduced in myeloma, increasing the risk of PC-AKI. • Correction of hypercalcaemia is necessary in myeloma before iodine-based contrast medium administration. • Bence-Jones proteinuria assessment in myeloma is unnecessary before iodine-based contrast medium administration.

  4. Peripheral blood eosinophilia associated with gastrointestinal administration of iodinated contrast media.

    Science.gov (United States)

    Plavsic, Branko M; Newman, Alan C; Reuther, Warren L; Terry, James A; Drnovsek, Valerie H

    2003-03-01

    This study was designed to assess whether gastrointestinal administration of iodinated contrast media results in peripheral blood eosinophilia. We studied 110 patients in a retrospective review. Diatrizoate meglumine and diatrizoate sodium for abdominal CT were administered to 98 of these patients; 22 of the 98 had also been given the same contrast medium administered by enema. The remaining 12 patients were given diatrizoate sodium for gastrointestinal fluoroscopy. A control group of 65 patients underwent single-contrast barium upper gastrointestinal or enema examinations. WBC and eosinophil counts were determined approximately 24 hr before the examination and every 24 hr thereafter, through the ninth day. Eosinophilia was detected in 17 (15.5%) of 110 patients after gastrointestinal administration of iodinated contrast media. The prevalence of eosinophilia after administration of iodinated contrast media was statistically significantly different compared with that in the control group, in which none of the 65 patients had eosinophilia (p contrast agents and lasted through the sixth day, with a peak on the fifth day. The prevalence of eosinophilia was independent of route of application, dose, or type of iodinated contrast medium. Eosinophilia in all cases was clinically asymptomatic. Eosinophilia that is caused by gastrointestinal administration of iodinated contrast media is a transient, clinically silent phenomenon. It may lead to unnecessary workup for known conditions associated with eosinophilia.

  5. Iodinated contrast media and patients with high-risk kidneys. Aiming at rational prevention

    International Nuclear Information System (INIS)

    Fontaine, B.; Frouge, C.; Gagey, N.

    1994-01-01

    Acute renal failure induced by iodinated contrast media (CM) accounts for about 10% of all hospital cases of renal failure, especially in azotemic patients. The specific anatomy and physiology of the inner medulla renalis render it particularly sensitive to even a moderate reduction in blood supply. Renal function will be estimated by measuring serum creatinine levels, before and within 72 hours after administration of the iodinated contrast medium. Hypovolaemia, diabetes mellitus-induced microangiopathy, nephrotoxic drugs and especially dehydratation may provoke renal accidents. Proper hydration, choosing a low osmolality medium and adequately spacing exposures to CM are elementary measures to be adopted to prevent renal failure. (authors)

  6. Intravascular enhancement with identical iodine delivery rate using different iodine contrast media in a circulation phantom.

    Science.gov (United States)

    Mihl, Casper; Wildberger, Joachim E; Jurencak, Tomas; Yanniello, Michael J; Nijssen, Estelle C; Kalafut, John F; Nalbantov, Georgi; Mühlenbruch, Georg; Behrendt, Florian F; Das, Marco

    2013-11-01

    Both iodine delivery rate (IDR) and iodine concentration are decisive factors for vascular enhancement in computed tomographic angiography. It is unclear, however, whether the use of high-iodine concentration contrast media is beneficial to lower iodine concentrations when IDR is kept identical. This study evaluates the effect of using different iodine concentrations on intravascular attenuation in a circulation phantom while maintaining a constant IDR. A circulation phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used (heart rate, 60 beats per minute; stroke volume, 60 mL; blood pressure, 120/80 mm Hg). Maintaining a constant IDR (2.0 g/s) and a constant total iodine load (20 g), prewarmed (37°C) contrast media with differing iodine concentrations (240-400 mg/mL) were injected into the phantom using a double-headed power injector. Serial computed tomographic scans at the level of the ascending aorta (AA), the descending aorta (DA), and the left main coronary artery (LM) were obtained. Total amount of contrast volume (milliliters), iodine delivery (grams of iodine), peak flow rate (milliliter per second), and intravascular pressure (pounds per square inch) were monitored using a dedicated data acquisition program. Attenuation values in the AA, the DA, and the LM were constantly measured (Hounsfield unit [HU]). In addition, time-enhancement curves, aortic peak enhancement, and time to peak were determined. All contrast injection protocols resulted in similar attenuation values: the AA (516 [11] to 531 [37] HU), the DA (514 [17] to 531 [32] HU), and the LM (490 [10] to 507 [17] HU). No significant differences were found between the AA, the DA, and the LM for either peak enhancement (all P > 0.05) or mean time to peak (AA, 19.4 [0.58] to 20.1 [1.05] seconds; DA, 21.1 [1.0] to 21.4 [1.15] seconds; LM, 19.8 [0.58] to 20.1 [1.05] seconds). This phantom study demonstrates that

  7. Beware of parotitis induced by iodine-containing contrast media.

    Science.gov (United States)

    Kohat, A K; Jayantee, K; Phadke, R V; Muthu, R; Singh, V; Misra, U K

    2014-01-01

    Carotid stenting is being increasingly used for revascularization of the moderate to severe carotid stenosis and thus its complications are increasingly being recognized. We report a rare complication of induced by iodine contrast in a patient undergoing carotid stenting. s. A 51 year old man after the second stenting developed multiple small infarcts in spite of the distal device. He also had painful parotid swelling which improved within a week. One should be aware of iodine parotitis s in the patients undergoing iodinated contrast study.

  8. Alterations of serum potassium, serum magnesium and adenosine diphosphate due to various contrast media containing iodine

    International Nuclear Information System (INIS)

    Lehrberger, G.

    1979-01-01

    As an introduction of the chemical structure of contrast media is explained. Then follows a survey about the complication rates in examinations with intravascularly applicable iodine-containing contrast media. In the next part clinical symptoms and signs of general and localized contrast media incompatibility reactions, the contrast medium protein reaction and the relationship between allergic reaction and contrast medium are explained. It was tried to attribute the large amount of side-effects to one primary reaction. In this connection the three above-mentioned components were investigated. (orig./MG) [de

  9. Use of Iodine-based contrast media in digital full-field mammography - initial experience

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Taupitz, M.; Bick, U.; Winzer, K.-J.; Huettner, C.; Muller, S.; Jeunehomme, F.; Hamm, B.

    2003-01-01

    Aim: To investigate the use of iodine-based contrast media in digital full-field mammography. Methods: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. Results: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. Conclusions: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted X-ray parameters, proper timing, and suitable subtraction software. (orig.) [de

  10. Longitudinal study of iodine in toenails following IV administration of an iodine-containing contrast agent

    International Nuclear Information System (INIS)

    Spate, V.L.; Morris, J.S.; Nichols, T.A.; Baskett, C.K.; Mason, M.M.; Horsman, T.L.; McDougall, I.R.

    1998-01-01

    The literature on the relationship between diet and thyroid cancer (TC) risk and the higher incidence of TC among Asian immigrants to the US compared to second and third generation subgroups has prompted epidemiologists to hypothesize that increased levels of iodine consumption may be associated with TC risk, particularly among persons with a history of clinical or subclinical thyroid dysfunction. At the University of Missouri Research Reactor (MURR), we have applied epiboron neutron activation analysis to investigate human nails as a dietary monitor for iodine. Preliminary studies have indicated a positive correlation between dietary iodine intake and the concentration of iodine in toenails. However, these studies are confounded by high iodine levels (up to 30 ppm) in approximately 5% of the nails studied. We hypothesize that, in the subjects we have studied, the high iodine levels may be due to iodine-containing medications, in particular contrast-agents containing iopamidol. This paper will report on longitudinal studies using contrast agent subjects who where followed-up for almost two years compared to a longitudinal control and a population mean. Based on this study, we suggest that iodine-containing contrast agents contaminate nail samples via non-specific binding in the short term followed by incorporation in the nail as a result of absorption. (author)

  11. Iodine-based contrast media, multiple myeloma and monoclonal gammopathies

    DEFF Research Database (Denmark)

    Stacul, Fulvio; Bertolotto, Michele; Thomsen, Henrik S

    2018-01-01

    OBJECTIVES: Many radiologists and clinicians still consider multiple myeloma (MM) and monoclonal gammopathies (MG) a contraindication for using iodine-based contrast media. The ESUR Contrast Media Safety Committee performed a systematic review of the incidence of post-contrast acute kidney injury...

  12. Contrast opacification for CT from iodine, gadolinium and ytterbium

    International Nuclear Information System (INIS)

    Zwicker, C.; Langer, M.; Ullrich, V.; Felix, R.

    1993-01-01

    The absorption of the elements iodine, gadolinium und ytterbium in various dilutions was studied in relation to CT. Regression analysis and specific CT density measurements showed that absorption decreases from gadolinium to ytterbium and iodine. These results were confirmed by experiments using ten dogs. Boli of 0.5 molar gadolinium used for angio-CT without table movement showed the largest increase in density in the aorta and liver with an average of 190 HU and 21 HU respectively compared with iodine which gave 157 HU and 12 HU respectively. The animal experimental studies suggest that gadolinium and ytterbium are suitable contrast media for dynamic CT investigations. (orig.) [de

  13. [Guideline 'Precautionary measures for contrast media containing iodine'

    NARCIS (Netherlands)

    Dijk Azn, R. van; Wetzels, J.F.M.; Dam, M.A. ten; Aarts, N.J.; Schimmelpenninck-Scheiffers, M.L.; Freericks, M.P.; Said, S.A.M.; Geenen, R.W.; Stuurman, A.; Everdingen, J.J. van

    2008-01-01

    Annually, 0.5-1 million injections of contrast media containing iodine are administered in the Netherlands. Almost all contrast media nowadays are low-osmolar and nonionic. Nevertheless, the development ofcontrast-induced nephropathy is still a relevant clinical problem. Through an initiative by the

  14. A Comparison of the Use of Contrast Media with Different Iodine Concentrations for Multidetector CT of the Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seung Chai; Kim, Seung Hyup; Cho, Jeong Yeon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2011-11-15

    To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan.

  15. A Comparison of the Use of Contrast Media with Different Iodine Concentrations for Multidetector CT of the Kidney

    Science.gov (United States)

    Jung, Seung Chai; Cho, Jeong Yeon

    2011-01-01

    Objective To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. Materials and Methods A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. Results The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). Conclusion The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan. PMID:22043154

  16. Contrast enhancement technique in brain 3D-CTA studies. Optimizing the amount of contrast medium according to scan time based on TDC

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi

    2008-01-01

    In three-dimensional CT angiography (3D-CTA), good reproducibility can be obtained by maintaining the maximum CT numbers (HU) at a specified level. However, the correlation between the scan time and the injection time showed that the maximum CT numbers increased and varied due to the additional contrast enhancement effect from recirculation of the injected contrast medium for longer injection times when the dose of iodinated contrast medium per unit time (mgI/s) was maintained at a specified level based on the time-density curve (TDC) of the phantom. The amount of contrast medium employed at our hospital has been optimized based on an iodinated contrast medium dose per unit time providing a contrast enhancement effect of 300 HU in the middle cerebral artery. Using this standard, a TDC phantom was employed to obtain an iodinated contrast medium dose per unit time, permitting equivalent maximum CT values (used as standard values) to be obtained by changing the injection time. A contrast-enhancement technique that accounts for the variation in the scan time was evaluated. Strong correlations were observed between the scan time and the injection time (R 2 =0.969) and between the injection time and the dose of iodinated contrast medium per unit body weight (R 2 =0.994). We conclude that adjusting the dose of iodinated contrast medium per unit body weight per unit time according to the scan time permits optimization of the contrast-enhancement technique. (author)

  17. Comparison of the Safety of Seven Iodinated Contrast Media

    Science.gov (United States)

    Seong, Jong-Mi; Choi, Nam-Kyong; Lee, Joongyub; Chang, Yoosoo; Kim, Ye-Jee; Yang, Bo Ram; Jin, Xue-Mei; Kim, Ju-Young

    2013-01-01

    We aimed to determine the characteristic adverse events (AEs) of iodinated contrast media (IOCM) and to compare the safety profiles of different IOCM. This study used the database of AEs reports submitted by healthcare professionals from 15 Regional Pharmacovigilance Centers between June 24, 2009 and December 31, 2010 in Korea. All reports of IOCM, including iopromide, iohexol, iopamidol, iomeprol, ioversol, iobitridol and iodixanol, were analyzed. Safety profiles were compared between different IOCM at the system organ level using the proportional reporting ratio (PRR) and 95% confidence interval (95% CI). Among a total of 48,261 reports, 6,524 (13.5%) reports were related to the use of IOCM. Iopromide (45.5%), iohexol (16.9%), iopamidol (14.3%) and iomeprol (10.3%) were identified as frequently reported media. 'Platelet, bleeding & clotting disorders' (PRR, 29.6; 95%CI, 1.9-472.6) and 'urinary system disorders' (PRR, 22.3; 95% CI, 17.1-29.1) were more frequently reported for iodixanol than the other IOCM. In conclusion, the frequency of AEs by organ class was significantly different between individual media. These differences among different IOCM should be considered when selecting a medium among various IOCM and when monitoring patients during and after its use to ensure optimum usage and patient safety. PMID:24339697

  18. Iodinated contrast agent-induced nephropathy

    International Nuclear Information System (INIS)

    Erley, C.

    2007-01-01

    Contrast-induced nephropathy (CIN) is a well-known complication of therapeutic and diagnostic procedures requiring contrast administration and accounts for 10% of acute renal failure in hospitalized patients. Although the incidence of this complication is relatively low, its consequences can be catastrophic. The development of CIN is associated with increased length of hospital stay, an increased requirement for acute dialysis, and an increased risk of death. Preexisting renal dysfunction, age, diabetes, congestive heart failure, and volume of administered contrast are all associated with a risk of developing CIN. Despite a large number of clinical trials that have evaluated prophylaxis strategies for CIN, no uniform strategies have been developed so far. The use of N-acetyl-L-cysteine (NAC) or theophylline in specific subgroups of patients has been shown to reduce dialysis requirement and mortality in patients undergoing angiographic procedures. Hemofiltration has also shown positive results. In this review we will discuss the epidemiology and the risk factors for CIN and the evidence for commonly employed prophylaxis strategies, and we will provide general recommendations with respect to CIN prevention and management. A practicable strategy to prevent CIN includes: correct identification of individuals at greatest risk, thorough evaluation of whether other diagnostic maneuvers could be employed instead (i.e., sonography), application of low-osmolar contrast media at the minimum acceptable dose, stopping potential nephrotoxic drugs (NSAID), hydration with sodium chloride 0.9% 1 ml/kg per h i.v. 12 h before and after CM application, administration of acetylcysteine 600 mg twice the day before and after (in cases of emergency investigation and high-risk patients 1200 mg i.v.), and theophylline (250-350 mg) the day before and the day after CM application (in cases of emergency investigation 5 mg/kg i.v.). (orig.) [de

  19. The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging. Implications for CT dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Perisinakis, Kostas; Damilakis, John [University of Crete, Department of Medical Physics, Medical School, Heraklion, Crete (Greece); University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Tzedakis, Antonis; Papadakis, Antonios E. [University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Spanakis, Kostas [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); Hatzidakis, Adam [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); University of Crete, Department of Radiology, Medical School, Heraklion, Crete (Greece)

    2018-01-15

    To investigate the effect of iodine uptake on tissue/organ absorbed doses from CT exposure and its implications in CT dosimetry. The contrast-induced CT number increase of several radiosensitive tissues was retrospectively determined in 120 CT examinations involving both non-enhanced and contrast-enhanced CT imaging. CT images of a phantom containing aqueous solutions of varying iodine concentration were obtained. Plots of the CT number increase against iodine concentration were produced. The clinically occurring iodine tissue uptake was quantified by attributing recorded CT number increase to a certain concentration of aqueous iodine solution. Clinically occurring iodine uptake was represented in mathematical anthropomorphic phantoms. Standard 120 kV CT exposures were simulated using Monte Carlo methods and resulting organ doses were derived for non-enhanced and iodine contrast-enhanced CT imaging. The mean iodine uptake range during contrast-enhanced CT imaging was found to be 0.02-0.46% w/w for the investigated tissues, while the maximum value recorded was 0.82% w/w. For the same CT exposure, iodinated tissues were found to receive higher radiation dose than non-iodinated tissues, with dose increase exceeding 100% for tissues with high iodine uptake. Administration of iodinated contrast medium considerably increases radiation dose to tissues from CT exposure. (orig.)

  20. Effects of iodinated contrast media on blood and endothelium

    International Nuclear Information System (INIS)

    Aspelin, Peter; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.; Molen, Aart J. van der

    2006-01-01

    The aim of the study was to assess the effects of iodinated contrast media on blood components and endothelium based on experimental and clinical studies and to produce clinically relevant guidelines for reducing thrombotic and hematologic complications following the intravascular use of contrast media. A report was drafted after review of the literature and discussions among the members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology. The final report was produced following discussion at the 12th European Symposium on Urogenital Radiology in Ljubljana, Slovenia (2005). Experimental data indicate that all iodinated contrast media produce an anticoagulant effect and that this effect is greater with ionic contrast media. Several of the in vitro and experimental in vivo studies on haematological effects of contrast media have not been confirmed by clinical studies. Low- or iso-osmolar contrast media should be used for diagnostic and interventional angiographic procedures, including phlebography. Meticulous angiographic technique is the most important factor for reducing the thrombotic complications associated with angiographic procedures. Drugs and interventional devices that decrease the risk of thromboembolic complications during interventional procedures minimize the importance of the effects of contrast media. (orig.)

  1. Effects of iodinated contrast media on blood and endothelium

    Energy Technology Data Exchange (ETDEWEB)

    Aspelin, Peter [Karolinska Institute/Huddinge University Hospital, Division of Radiology, Centre for Surgical Sciences, Stockholm (Sweden); Stacul, Fulvio [Institute of Radiology, Trieste (Italy); Thomsen, Henrik S. [Copenhagen University Hospital at Herlev, Department of Diagnostic Radiology 54E2, Herlev (Denmark); Morcos, Sameh K. [Sheffield Teaching Hospitals NHS Trust, Department of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom); Molen, Aart J. van der [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands)

    2006-05-15

    The aim of the study was to assess the effects of iodinated contrast media on blood components and endothelium based on experimental and clinical studies and to produce clinically relevant guidelines for reducing thrombotic and hematologic complications following the intravascular use of contrast media. A report was drafted after review of the literature and discussions among the members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology. The final report was produced following discussion at the 12th European Symposium on Urogenital Radiology in Ljubljana, Slovenia (2005). Experimental data indicate that all iodinated contrast media produce an anticoagulant effect and that this effect is greater with ionic contrast media. Several of the in vitro and experimental in vivo studies on haematological effects of contrast media have not been confirmed by clinical studies. Low- or iso-osmolar contrast media should be used for diagnostic and interventional angiographic procedures, including phlebography. Meticulous angiographic technique is the most important factor for reducing the thrombotic complications associated with angiographic procedures. Drugs and interventional devices that decrease the risk of thromboembolic complications during interventional procedures minimize the importance of the effects of contrast media. (orig.)

  2. Radiculography with reduced amounts of contrast medium

    International Nuclear Information System (INIS)

    Signorini, E.; Caputo, N.; Chiurulla, C.; Ciorba, E.; Pelliccioli, G.P.; Cianciulli, E.

    1984-01-01

    Because of the frequency and seriousness of side effects observed after radiculography, due to, among the other things, the amount of contrast medium, the authors describe a method that gives diagnostically satisfactory results using a low dose of contrast and a tangent-beam technique. Among 106 patients undergoing radiculography with a tangent-beam technique and Iopamidol, only 4 developed mild side effects, namely headache in three cases and headache with nausea in one. (Author)

  3. Radiculography with water-soluble contraste medium

    International Nuclear Information System (INIS)

    Araujo Pinheiro, R.S. de

    1987-01-01

    The etiologic diagnosis of the lumbar pain is discussed. The radiculography with water-soluble contrast medium is used and 250 cases are studied. Some practical criteria of indication executation and interpretation of the examination are reported. (M.A.C.) [pt

  4. Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography

    International Nuclear Information System (INIS)

    Baldelli, P; Bravin, A; Maggio, C Di; Gennaro, G; Sarnelli, A; Taibi, A; Gambaccini, M

    2006-01-01

    Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml -1 and 1.34 mg ml -1 for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml -1 and 1.31 mg ml -1 . With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml -1 (8 mm diameter) and 5.75 mg ml -1 (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml -1 (8 mm diameter) and 1.57 mg ml -1 (5 mm diameter)

  5. Viscosity of iodinated contrast agents during renal excretion

    International Nuclear Information System (INIS)

    Jost, Gregor; Lengsfeld, Philipp; Lenhard, Diana C.; Pietsch, Hubertus; Huetter, Joachim; Sieber, Martin A.

    2011-01-01

    Objective: Modern iodinated non-ionic contrast agents (CAs) can be classified based on their molecular structure into monomeric and dimeric CAs and have at comparable iodine concentrations a different viscosity and osmolality. During their renal excretion, CAs are concentrated in the renal tubuli which might enhance the viscosity difference between monomeric and dimeric CAs. The viscosity of a CA might have an underestimated importance for renal safety, as suggested by recent publications. In this study, we investigated the viscosities of CAs at the concentrations expected to be present in renal tubules. This concentration process was simulated in vitro using dialysis. Furthermore, we investigated urine viscosity and urine flow in rodents after administration of several non-ionic monomeric and dimeric CAs. Materials and methods: To estimate the viscosity of the CAs in vivo, we performed an in vitro dialysis of monomeric and dimeric CAs at various physiological osmolalities of the renal tubulus (290, 400, 500, 700 and 1000 mOsm/kg H 2 O). Following the dialysis, the iodine concentrations and the viscosities of the CAs were determined. Furthermore, to investigate the concentration process in vivo, we measured the urine viscosity and the urine flow in Han Wister rats after the administration of Iopromide, Iohexol, Ioversol, Iomeprol, Iodixanol, and Iosimenol at comparable iodine concentrations. As a control, saline was injected at the same volume. Results: In vitro dialysis of the dimeric CA increased the iodine concentration and strongly increased the viscosity at all tested osmolalities. In contrast, for the monomeric agents an increase in concentration and viscosity was observed only at 700 as well 1000 mOsm/kg H 2 O but to a lesser extent. In summary, dialysis strongly enhanced the viscosity differences between the non-ionic monomeric and dimeric CAs. The administration of dimeric CAs leads to a strong increase in urine viscosity; this was not observed for the

  6. Viscosity of iodinated contrast agents during renal excretion

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor, E-mail: Gregor.Jost@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lengsfeld, Philipp, E-mail: Philipp.Lengsfeld@bayer.com [Global Medical Affairs Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lenhard, Diana C., E-mail: Diana.Lenhard@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Pietsch, Hubertus, E-mail: Hubertus.Pietsch@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Huetter, Joachim, E-mail: Joachim.Huetter@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Sieber, Martin A., E-mail: Martin.Sieber@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany)

    2011-11-15

    Objective: Modern iodinated non-ionic contrast agents (CAs) can be classified based on their molecular structure into monomeric and dimeric CAs and have at comparable iodine concentrations a different viscosity and osmolality. During their renal excretion, CAs are concentrated in the renal tubuli which might enhance the viscosity difference between monomeric and dimeric CAs. The viscosity of a CA might have an underestimated importance for renal safety, as suggested by recent publications. In this study, we investigated the viscosities of CAs at the concentrations expected to be present in renal tubules. This concentration process was simulated in vitro using dialysis. Furthermore, we investigated urine viscosity and urine flow in rodents after administration of several non-ionic monomeric and dimeric CAs. Materials and methods: To estimate the viscosity of the CAs in vivo, we performed an in vitro dialysis of monomeric and dimeric CAs at various physiological osmolalities of the renal tubulus (290, 400, 500, 700 and 1000 mOsm/kg H{sub 2}O). Following the dialysis, the iodine concentrations and the viscosities of the CAs were determined. Furthermore, to investigate the concentration process in vivo, we measured the urine viscosity and the urine flow in Han Wister rats after the administration of Iopromide, Iohexol, Ioversol, Iomeprol, Iodixanol, and Iosimenol at comparable iodine concentrations. As a control, saline was injected at the same volume. Results: In vitro dialysis of the dimeric CA increased the iodine concentration and strongly increased the viscosity at all tested osmolalities. In contrast, for the monomeric agents an increase in concentration and viscosity was observed only at 700 as well 1000 mOsm/kg H{sub 2}O but to a lesser extent. In summary, dialysis strongly enhanced the viscosity differences between the non-ionic monomeric and dimeric CAs. The administration of dimeric CAs leads to a strong increase in urine viscosity; this was not observed for

  7. Preclinical Studies of a Kidney Safe Iodinated Contrast Agent.

    Science.gov (United States)

    Rowe, Elizabeth S; Rowe, Vernon D; Biswas, Sangita; Mosher, Gerold; Insisienmay, Lovella; Ozias, Marlies K; Gralinski, Michael R; Hunter, John; Barnett, James S

    2016-09-01

    Contrast-induced acute kidney injury (CI-AKI) is a serious complication of the use of iodinated contrast agents. This problem is particularly acute in interventional neurology and interventional cardiology, probably due to the intra-arterial route of injection, high contrast volumes, and preexisting risk factors of these patients. In an attempt to develop a contrast agent that is less damaging to the kidneys, we have studied the effects of adding a small amount of the substituted cyclodextrin, sulfobutyl-ether-β-cyclodextrin (SBECD), to iohexol in rodent models of renal toxicity. Renally compromised mice and rats were injected with iohexol and iohexol-SBECD via the tail vein. The renal pathology, creatinine clearance, and survival benefits of iohexol-SBECD were studied. The safety of direct intra-arterial injection of the iohexol-SBECD formulation was studied in a dog heart model system. Mechanism of action studies in cell culture model using a human kidney cell line was performed using flow cytometry. Nephrotoxicity was significantly reduced using iohexol-SBECD compared to iohexol alone, at mole ratios of iohexol:SBECD of 1:0.025. SBECD increased survival from 50% to 88% in a rat survival study. In the dog heart model, iohexol-SBECD was safe. Cell culture studies suggest that SBECD interferes with the early stages of contrast-induced apoptosis in a human renal cell line. We have shown that the addition of a small amount of SBECD (one molecule of SBECD per 40 iohexol molecules) significantly protects rodent kidneys from CI-AKI. Further development of this new formulation of iodinated contrast is warranted. © 2016 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  8. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Societ...

  9. Renal Safety of Iodinated Contrast Media Depending on Their Osmolarity – Current Outlooks

    International Nuclear Information System (INIS)

    Mruk, Bartosz

    2016-01-01

    Iodinated contrast media (ICM) are commonly administered pharmaceutical agents. Most often they are used intravenously and intraarterially. Although iodinated contrast agents are relatively safe and widely used, adverse events occur and questions remain about their use, safety, and interactions. The most important adverse effects of contrast media include hypersensitivity reactions, thyroid dysfunction, and contrast-induced nephropathy. Radiologists must be aware of the risk factors for reactions to contrast media. Nonionic iodinated contrast agents can be divided into monomeric, low-osmolar, and dimeric, iso-osmolar classes. The osmotic characteristics of contrast media have been a significant focus in many investigations of contrast-induced nephropathy

  10. Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Behrendt, Florian F.; Keil, Sebastian; Plumhans, Cedric; Guenther, Rolf W. [RWTH Aachen University, Department of Diagnostic Radiology, University Hospital, Aachen (Germany); Pietsch, Hubertus; Jost, Gregor; Sieber, Martin A.; Seidensticker, Peter [Bayer Schering Pharma AG, Berlin (Germany); Mahnken, Andreas H. [RWTH Aachen University, Department of Diagnostic Radiology, University Hospital, Aachen (Germany); RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute for Biomedical Engineering, Aachen (Germany)

    2010-07-15

    To compare intra-individual contrast enhancement in multi-detector-row computed tomography (MDCT) using contrast media (CM) containing 300, 370 and 400 mg iodine per ml (mgI/ml). Six pigs underwent repeated chest MDCT using three different CM (iopromide 300, iopromide 370, iomeprol 400). An identical iodine delivery (IDR) rate of 1.5 gI/s and a constant total iodine dose of 300 mg/kg body weight were used. Dynamic CT were acquired at the level of the pulmonary artery, and the ascending and descending aorta. After the time enhancement curves were computed, the pulmonary and aortic peak enhancement, time to peak and plateau time above 300 HU were calculated. Intra-individual peak contrast enhancement was significantly higher for the 300 mgI/ml contrast medium compared with the 370 and 400 mgI/ml media: pulmonary trunk 595 HU vs 516 HU (p = 0.0093) vs 472HU (p = 0.0005), and aorta 505 HU vs 454 HU (p = 0.0008) vs 439 HU (p = 0.0001), respectively. Comparison of time to peaks showed no significant difference. Plateau times were significantly longer for the 300 mgI/ml than for the 370 and 400 mgI/ml CM at all anatomical sites. Given normalised IDR and total iodine burden, the use of CM with a standard concentration with 300 mg iodine/ml provides improved contrast enhancement compared with highly concentrated CM in the chest. (orig.)

  11. Severe reactions to iodinated contrast agents: is anaphylaxis responsible?

    International Nuclear Information System (INIS)

    Dewachter, P.; Mouton-Faivre, C.

    2001-01-01

    The etiology of severe reactions following injection of iodinated contrast agent is the subject of controversy. No consensus has been established regarding the management of patients at risk, risk factors and pre-medication because in most cases published no diagnostic exploration has been carried out on patients who have experienced a severe reaction. Diagnosis of drug anaphylaxis is based on clinical history, proof of mediator release and drug specific IgE antibodies (when the technique is available) or cutaneous tests (when direct technique is not available). This approach has been adopted for etiologic diagnosis of 5 clinical cases of severe anaphylactoid reactions (including one death) following the injection of ionic and non ionic contrast agents. Clinical symptoms, biology and cutaneous tests are consistent with anaphylaxis. Any patient who has had a severe anaphylactoid reaction following injection of a contrast agent should undergo an allergology assessment to confirm the diagnosis and identify the culprit contrast agent. Indeed, no pre-medication has proved efficient for the prevention of subsequent allergic reactions. (author)

  12. General toxicity of water soluble iodinated contrast media: pathogenesis

    International Nuclear Information System (INIS)

    Moreau, J.F.; Giwerc, M.; Chabriais, J.; Rotkopf, L.

    1987-01-01

    The accidents related to the general toxicity of the watersoluble iodinated contrast media are unfrequent. They still exist despite the availability of new kinds of low osmolar molecules. Their pathogenesis is not yet clearly defined. An anaphylactic mechanism cannot give a satisfying explanation because specific IgE have been exceptionally found in humans. Two theories are discussed. Lalli has made an emphasis on the role played by stress and anxiety. The other theory is based on the prominent role played by the lesion of the vascular endothelial cells then the activation of factor XII. A vicious circle is created by the liberation of pre- and neo-formated ligands, eventually after the activation of the complement system [fr

  13. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Society...... or delayed reading intradermal). The main risk factors for LAR are a previous reaction to contrast medium, a history of allergy, and interleukin-2 treatment. Most skin reactions are mild or moderate and self-limiting. MANAGEMENT: Management is symptomatic and similar to the management of other drug......-induced skin reactions. To reduce the risk of repeat reactions avoidance of the relevant CM and any cross-reacting agents identified by skin testing is recommended....

  14. Iodinated contrast media and contrast-induced nephropathy: is there a preferred cost-effective agent?

    Science.gov (United States)

    Sharma, Samin K

    2008-05-01

    Over 20 years have passed since the introduction of the tri-iodinated low-osmolar nonionic contrast agents such as iopamidol, iohexol, ioversol and iopromide. During this time, most cardiology practices have switched to these nonionic agents to avoid the nuisance side effects and cardiac adverse events associated with the older ionic contrast agents. Although the improved tolerability of the nonionic agents is generally attributed to their decreased osmolality (approximately half that of the older ionic contrast agents), in fact, these contrast agents also differ from the older agents in their ionicity, viscosity and direct chemotoxicity. The impact of these properties on safety, together with cost differences, should be considered when selecting a contrast agent.

  15. Contrast medium-induced nephropathy: Aspects on incidence ...

    African Journals Online (AJOL)

    Contrast media-induced nephropathy (CIN) is a well-known complication of radiological examinations employing iodine contrast media (I-CM). The rapid development and frequent use of coronary interventions and multi-channel detector computed tomography with concomitant administration of relatively large doses of ...

  16. Apparition of iodinated contrast agents in twin neonatal gastrointestinal tracts after maternal contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Kato, Hiroki; Kanematsu, Masayuki; Kato, Zenichiro; Kondo, Naomi; Orii, Kenji E.; Morimoto, Masahiro

    2011-01-01

    We describe a case of the appearance of iodinated contrast agents in the same locations of twins' neonatal gastrointestinal tracts 1 day after maternal contrast-enhanced computed tomography (CT). The CT examination had been performed on the expectant mother for suspected deep venous thrombosis on the day previous to the twin delivery. At 23 h after the CT examination and after cesarean section, iodinated contrast agents appeared in the same place in the twins' neonatal gastrointestinal tracts, mainly in the ascending colon, on plain abdominal radiographs. Radiologists, obstetricians, and pediatricians should understand the mechanism of appearance of iodinated contrast agents in fetal gastrointestinal tracts when the expectant mother had been given iodinated contrast agents intravenously shortly before delivery. (author)

  17. Gadolinium-DTPA (Magnevist) as a contrast medium for arterial DSA

    International Nuclear Information System (INIS)

    Schild, H.H.; Weber, W.; Boeck, E.; Mildenberger, P.; Strunk, H.; Dueber, C.; Grebe, P.; Schadmand-Fischer, S.; Thelen, M.

    1994-01-01

    16 DSA investigations using intra-arterial Gd-DTPA were performed on 12 patients. The contrast medium was administered either as a 0.5 molar gadolinium solution (commercially available) or diluted with distilled water to a 0.2 -0.4 molar gadolinium solution. The injection was made either by pressure injector or by hand. The aortic arch, abdominal aorta and pelvic and lower limb arteries were examined. 14 of the 16 procedures were diagnostically adequate, but compared with iodinated contrast materials, contrast was less marked. There were no cardiovascular, neurological or allergic side effects. Three patients suffered a feeling of heat and one patient had mild pain during the injection. Even large volumes rapidly injected (up to 20 ml/s of the commercially available solution) were well tolerated. DSA with intra-arterial Gd-DTPA seems to be a suitable alternative for vascular imaging if iodine-containing contrast materials are contraindicated. (orig.) [de

  18. Nanotoxic Profiling of Novel Iron Oxide Nanoparticles Functionalized with Perchloric Acid and SiPEG as a Radiographic Contrast Medium

    Directory of Open Access Journals (Sweden)

    Muhamad Idham Mohamed

    2015-01-01

    Full Text Available Emerging syntheses and findings of new metallic nanoparticles (MNPs have become an important aspect in various fields including diagnostic imaging. To date, iodine has been utilized as a radiographic contrast medium. However, the raise concern of iodine threats on iodine-intolerance patient has led to search of new contrast media with lower toxic level. In this animal modeling study, 14 nm iron oxide nanoparticles (IONPs with silane-polyethylene glycol (SiPEG and perchloric acid have been assessed for toxicity level as compared to conventional iodine. The nanotoxicity of IONPs was evaluated in liver biochemistry, reactive oxygen species production (ROS, lipid peroxidation mechanism, and ultrastructural evaluation using transmission electron microscope (TEM. The hematological analysis and liver function test (LFT revealed that most of the liver enzymes were significantly higher in iodine-administered group as compared to those in normal and IONPs groups P<0.05. ROS production assay and lipid peroxidation indicator, malondialdehyde (MDA, also showed significant reductions in comparison with iodine group P<0.05. TEM evaluation yielded the aberration of nucleus structure of iodine-administered group as compared to those in control and IONPs groups. This study has demonstrated the less toxic properties of IONPs and it may postulate that IONPs are safe to be applied as radiographic contrast medium.

  19. A Complete Resolution of Sialadenitis Induced by Iodine Containing Contrast with Intravenous Dexamethasone Infusion

    OpenAIRE

    Homam Alkaied; Kassem Harris; Basem Azab; Marcel Odaimi

    2012-01-01

    Salivary gland enlargement following the administration of iodine is an extremely rare event, and the pathophysiology of iodine-induced sialadenitis is not yet fully known. The onset of symptoms can start within a few minutes to five days after contrast administration. The course of iodine-induced sialadenitis is extremely benign, and rapid resolution of symptoms is expected without treatment. We report the case of a 59-year-old white female who noted mildly painful swelling involving the rig...

  20. Comparison of differently viscous iodinated and bariumcontaining contrast agents in the detection of pharyngeal perforation

    International Nuclear Information System (INIS)

    Keberle, M.; Wittenberg, G.; Trusen, A.; Hahn, D.; Baumgartner, W.

    2001-01-01

    Purpose: In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Methods: Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. Results: In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous that the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Conclusions: Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose. (orig.) [de

  1. Comparison between two positive and one negative oral contrast medium for abdominal CT diagnosis

    International Nuclear Information System (INIS)

    Zwaan, M.; Gmelin, E.

    1989-01-01

    In a prospective randomised study three groups of 30 patients each were subjected to CT of the entire abdomen. The oral intestinal contrast media used were iodine solution (2%), barium suspension (1.5%) and paraffin emulsion (25%). The results were evaluated according to imaging, artifacts, assessability of the intestinal wall, taste and side effects. All three contrast media are suitable for marking the gastrointestinal tract; paraffin shows advantages in the upper part of the tract and is the only medium that enables assessment of the wall, while causing the lowest rate of artifacts. Barium has a high acceptance and the best tolerance of all contrast agents. (orig.) [de

  2. Renal clearance of an ionic high-osmolar and a nonionic low-osmolar contrast medium

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Vestergaard, A.; Nielsen, S.L.; Fogh-Andersen, N.; Golman, K.; Dorph, S.

    1991-01-01

    One hundred patients with normal serum creatinine concentration underwent intravenous urography with either an ionic high-osmolar (diatrizoate) or a nonionic low-osmolar (iopamidol) contrast medium after randomization. Before injection of the contrast medium, a blood sample was drawn for determinating serum creatinine concentration, and a urine sample for measurement of urine osmolality. Using x-ray fluorescence, the plasma concentration of iodine (contrast medium) was determined on blood samples drawn approximately 3 and 4 hours after injection of the contrast medium. The glomerular filtration rate was calculated by two different formulas: one requiring only a single sample and one requiring at least two samples (standard). There were poor correlations between the standard contrast medium clearance and the serum creatinine concentration, the estimated creatinine clearance (calculated from a nomogram), as well as the urine osmolality. The 3-hour and the 4-hour single-sample values correlated well with the two-sample values for both contrast media. In patients with normal serum creatinine, the glomerular filtration rate determined by measuring the contrast medium concentration in a single plasma sample obtained at 3 hours, is almost identical to the value determined from two samples. Consequently, two samples are unnecessary

  3. Mechanism of dark decomposition of iodine donor in the active medium of a pulsed chemical oxygen - iodine laser

    International Nuclear Information System (INIS)

    Andreeva, Tamara L; Kuznetsova, S V; Maslov, A I; Sorokin, Vadim N

    2002-01-01

    A scheme is proposed that describes the dark decomposition of iodide - the donor of iodine - and the relaxation of singlet oxygen in the chlorine-containing active medium of a pulsed chemical oxygen - iodine laser (COIL). For typical compositions of the active media of pulsed COILs utilising CH 3 I molecules as iodine donors, a branching chain reaction of the CH 3 I decomposition accompanied by the efficient dissipation of singlet oxygen is shown to develop even at the stage of filling the active volume. In the active media with CF 3 I as the donor, a similar chain reaction is retarded due to the decay of CF 3 radicals upon recombination with oxygen. The validity of this mechanism is confirmed by a rather good agreement between the results of calculations and the available experimental data. The chain decomposition of alkyliodides accompanied by an avalanche production of iodine atoms represents a new way of efficient chemical production of iodine for a COIL. (active media)

  4. MDCT angiography of the pulmonary arteries: intravascular contrast enhancement does not depend on iodine concentration when injecting equal amounts of iodine at standardized iodine delivery rates

    International Nuclear Information System (INIS)

    Keil, S.; Plumhans, C.; Behrendt, F.F.; Das, M.; Muehlenbruch, G.; Mahnken, A.H.; Guenther, R.W.; Stanzel, S.; Seidensticker, P.; Knackstedt, C.; Wildberger, J.E.

    2008-01-01

    To compare the impact of iodine concentration using two different contrast materials (CM) at standardized iodine delivery rate (IDR) and overall iodine load in 16-multidetector-row-CT-angiography (MDCTA) of the pulmonary arteries of 192 patients with known or suspected pulmonary embolism. One hundred three patients (group A) received 148 ml of a CM containing 300 mg iodine/ml (Ultravist 300 trademark, BayerScheringPharma) at a flow rate of 4.9 ml/s. Eighty-nine patients (group B) received 120 ml of a CM with a concentration of 370 mg iodine/ml (Ultravist370 trademark) at a flow rate of 4.0 ml/s, resulting in a standardized IDR (∝1.5 gI/s) and the same overall amount of iodine (44.4 g). Both CM injections were followed by a saline chaser. Mean density values were determined in the pulmonary trunk, the ascending and the descending aorta, respectively. Applying repeated-measures ANOVA, no statistically significant differences between both MDCTA protocols were found (p=0.5790): the mean density in the pulmonary trunk was 355±116 Hounsfield Units (group A) and 358±115 (group B). The corresponding values for the ascending and descending aorta were 295±79 (group A) and 284±65 (group B) as well as 272±71 and 262±70. In conclusion, the use of standardized IDR and overall iodine load provides comparable intravascular CM density in pulmonary 16-MDCTA for delivering contrast materials with different iodine concentrations. (orig.)

  5. Effects of use of the lodine contrast medium on gamma camera imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pyo, Sung Jae; Cho, Yun Ho [Dept. of Nuclear Medicine, Inha University hospital, Incheon (Korea, Republic of); Choi, Jae Ho [Dept. of Radiological Technology, Ansan College, Ansan (Korea, Republic of)

    2016-12-15

    Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficientin an SPECT/CT attenuation correction will be considered herein. For experimental materials used 99mTcO4 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of 99mTcO4. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope 99mTcO4 and the saline solution were mixed. In the tomography for mixing of the radioactive isotope 99mTcO4 and saline solution, the mean counting rate without correction by the CT absorption coefficient is 182±26 counts, while the counting rate with correction by the CT absorption coefficient is 531.3±34 counts. In the tomography for mixing of the radioactive isotope 99mTcO4 and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were 166±29, 158.3±17, 154±36, and 150±33 counts depending on the densities of the contrast medium, while the mean values after attenuation correction were 515±03, 503±10, 496±31, and 488.7±33 counts, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of diagnosis.

  6. A Complete Resolution of Sialadenitis Induced by Iodine Containing Contrast with Intravenous Dexamethasone Infusion

    Directory of Open Access Journals (Sweden)

    Homam Alkaied

    2012-01-01

    Full Text Available Salivary gland enlargement following the administration of iodine is an extremely rare event, and the pathophysiology of iodine-induced sialadenitis is not yet fully known. The onset of symptoms can start within a few minutes to five days after contrast administration. The course of iodine-induced sialadenitis is extremely benign, and rapid resolution of symptoms is expected without treatment. We report the case of a 59-year-old white female who noted mildly painful swelling involving the right side of her face within five days of receiving intravenous iodine-containing contrast. A diagnosis of iodine-related sialadenitis was made. She was given 20 mg of decadron intravenously, with prompt resolution of the swelling within a few hours.

  7. Monte Carlo dosimetry of iodine contrast objects in a small animal microCT

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Villafuerte, M., E-mail: mercedes@fisica.unam.mx [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico); Martinez-Davalos, A. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico)

    2011-08-21

    Small animal microcomputed tomography (microCT) studies with iodine-based contrast media are commonly used in preclinical research. While the use of contrast media improves the quality of the images, it can also result in an increase in the absorbed dose to organs with high concentration of the contrast agent, which might cause radiation damage to the animal. In this work we present the results of a Monte Carlo investigation of a microCT dosimetry study using mouse-sized cylindrical water phantoms with iodine contrast insets for different X-ray spectra (Mo and W targets, 30-80 kVp), iodine concentrations (0, 5, 10 and 15 mg mL{sup -1}) and contrast object sizes (3 and 10 mm diameter). Our results indicate an absorbed dose increase in the contrast-inset regions with respect to the absorbed dose distribution within a reference uniform water phantom. The calculated spatial absorbed dose distributions show large gradients due to beam hardening effects, and large absorbed dose enhancement as the mean energy of the beam and iodine concentration increase. We have found that absorbed doses in iodine contrast objects can increase by a factor of up to 12 for a realistic 80 kVp X-ray spectra and an iodine concentration of 15 mg mL{sup -1}.

  8. Iodinated contrast media alter immune responses in pro-inflammatory states.

    LENUS (Irish Health Repository)

    O'Donnell, David H

    2010-07-01

    Hypertonic saline causes a transient elevation of blood osmolality and has been shown to alter cellular inflammatory responses in pro-inflammatory states. Intravascular administration of iodine contrast media also causes a transient elevation of blood osmolarity.

  9. Ultrasound-promoted iodination of pyrazoles in aqueous medium

    Directory of Open Access Journals (Sweden)

    Jéssica Kunsminskas

    2012-06-01

    Full Text Available Several pharmacological activities have been devoted to pyrazole containing molecules. In particular, 4-iodopyrazoles have been employed as key starting materials in cross-coupling chemistry and metal-iodine exchange reactions that focus on the synthesis of such biologically important compounds. Unfortunately, existing methods for the synthesis of 4-iodopyrazoles are not in agreement with the environmental requirements due to a series of drawbacks including the use of large excess of reagents, the generation of toxic waste and long reaction times. Recently, we developed a fast and mild reaction condition for the iodination of aromatic compounds using an I2/H2O2 system water as a nonflammable and innocuous solvent and ultrasonic irradiation as energy source. In this work, we present the application of this methodology for the iodination of pyrazoles (Scheme. Initially, a series of pyrazoles were efficiently prepared starting from 1,3-dicarbonyl compounds and hydrazines under ultrasonic irradiation. Three examples from the pyrazoles were subjected to the iodination condition shown above. Iodopyrazoles were obtained in 63-65% yields.

  10. Carbon dioxide as a substitute for iodine contrast in arteriography during embolectomy

    Energy Technology Data Exchange (ETDEWEB)

    Wolosker, Nelson; Teivelis, Marcelo Passos; Mendes, Cynthia de Almeida; Nishinari, Kenji; Ribeiro, Mariângela de Freitas; Kuzniec, Sergio [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2015-07-01

    Acute limb ischemia can be potentially harmful to the limb and life threatening. Renal failure is a possible outcome associated with release of products of ischemic limb reperfusion. Some authors reported the benefit of performing angiography after embolectomy, even though iodine contrast is also nephrotoxic. We report a case of embolectomy on a patient with renal insufficiency in whom carbon dioxide was used as a substitute for iodine contrast.

  11. Optical tracking of contrast medium bolus to optimize bolus shape and timing in dynamic computed tomography

    International Nuclear Information System (INIS)

    Eisa, Fabian; Brauweiler, Robert; Peetz, Alexander; Hupfer, Martin; Nowak, Tristan; Kalender, Willi A

    2012-01-01

    One of the biggest challenges in dynamic contrast-enhanced CT is the optimal synchronization of scan start and duration with contrast medium administration in order to optimize image contrast and to reduce the amount of contrast medium. We present a new optically based approach, which was developed to investigate and optimize bolus timing and shape. The time-concentration curve of an intravenously injected test bolus of a dye is measured in peripheral vessels with an optical sensor prior to the diagnostic CT scan. The curves can be used to assess bolus shapes as a function of injection protocols and to determine contrast medium arrival times. Preliminary results for phantom and animal experiments showed the expected linear behavior between dye concentration and absorption. The kinetics of the dye was compared to iodinated contrast medium and was found to be in good agreement. The contrast enhancement curves were reliably detected in three mice with individual bolus shapes and delay times of 2.1, 3.5 and 6.1 s, respectively. The optical sensor appears to be a promising approach to optimize injection protocols and contrast enhancement timing and is applicable to all modalities without implying any additional radiation dose. Clinical tests are still necessary. (note)

  12. Contrast medium-induced nephropathy: the pathophysiology

    DEFF Research Database (Denmark)

    Persson, P B; Tepel, Martin

    2006-01-01

    A widespread, rather general, definition of contrast-induced nephropathy (CIN) is an impairment in renal function occurring within 3 days following the intravascular administration of contrast media (CM) and the absence of an alternative aetiology. In spite of the vast clinical importance of CIN...... haemodynamics, regional hypoxia, auto-, and paracrine factors (adenosine, endothelin, reactive oxygen species) to direct cytotoxic effects. Although these potential mediators of CIN will be discussed separately, several factors may act in concert to perturb kidney function after exposure to contrast media. From...... the current knowledge of the mechanisms causing CIN, it is not possible to recommend a certain class of contrast media, except to avoid large doses of CM of the first generation. From a pathophysiological perspective, volume expansion is effective in avoiding CIN, since water permeability of the collecting...

  13. Pure and diluted contrast medium in the evaluation of portal venous system with digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Pozzato, C.; Nessi, R.; Raiteri, R.; Uscenghi, C.; Opocher, E.; Santambrogio, R.

    1990-01-01

    We report the results of intra-arterial digital subtraction angiography (DSA) in 100 patients with portal hypertension. The portal venous system was evaluated; all patients underwent angiography of the celiac and superior mesenteric arteries before surgery. Forty-four of them were also examined after Warren splenorenal shunts. Therefore, a total of 144 exams was evaluated. The authors always employed low-osmolality ionic and non-ionic contrast media (iodine concentration: 300-350 mg/ml). In 70 cases pure contrast medium was injected (20/25 ml): in the extant 74 cases it was diluted with an equal volume of saline solution (osmolality and iodine concentration reduced by 50%). Intra-arterial DSA always visualized portal venous system, collateral circulation, shunt location and postoperative changes. The mayor advantage of intra-arterial DSA is the smaller amount of contrast medium injected, so that local and systemic side effects are rare. According to our experience, it is best to dilute the contrast medium and inject the same amount as in conventional angiography, at the same rate. Other well-known advantages of intra-arterial DSA are quicker execution, less injury to arteries using smaller caliber catheters, and low cost. The major disadvantage of intra-arterial DSA, as it appeared also in our study, is the field size of the intensifier, which in our case was limited to 6-9 inches. This is an insufficient coverage for the whole portal system to be studied, and some contrast medium injections become therefore necessary. An average of 3 injections were given to each patient. This problem reduces the advantage of less contrast medium per injection. At any rate, even though intra-arterial DSA exhibits this limitation, it can nevertheless yield important information in the pre- and postoperative evaluation of patients with portal hypertension

  14. Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit.

    Science.gov (United States)

    Rosado-Méndez, I; Palma, B A; Brandan, M E

    2008-12-01

    Contrast-medium-enhanced digital mammography (CEDM) is an image subtraction technique which might help unmasking lesions embedded in very dense breasts. Previous works have stated the feasibility of CEDM and the imperative need of radiological optimization. This work presents an extension of a former analytical formalism to predict contrast-to-noise ratio (CNR) in subtracted mammograms. The goal is to optimize radiological parameters available in a clinical mammographic unit (x-ray tube anode/filter combination, voltage, and loading) by maximizing CNR and minimizing total mean glandular dose (D(gT)), simulating the experimental application of an iodine-based contrast medium and the image subtraction under dual-energy nontemporal, and single- or dual-energy temporal modalities. Total breast-entrance air kerma is limited to a fixed 8.76 mGy (1 R, similar to screening studies). Mathematical expressions obtained from the formalism are evaluated using computed mammographic x-ray spectra attenuated by an adipose/glandular breast containing an elongated structure filled with an iodinated solution in various concentrations. A systematic study of contrast, its associated variance, and CNR for different spectral combinations is performed, concluding in the proposal of optimum x-ray spectra. The linearity between contrast in subtracted images and iodine mass thickness is proven, including the determination of iodine visualization limits based on Rose's detection criterion. Finally, total breast-entrance air kerma is distributed between both images in various proportions in order to maximize the figure of merit CNR2/D(gT). Predicted results indicate the advantage of temporal subtraction (either single- or dual-energy modalities) with optimum parameters corresponding to high-voltage, strongly hardened Rh/Rh spectra. For temporal techniques, CNR was found to depend mostly on the energy of the iodinated image, and thus reduction in D(gT) could be achieved if the spectral energy

  15. Interactions between iodinated contrast media and tissue plasminogen activator: In vitro comparison study.

    Science.gov (United States)

    Vörös, Eszter; Deres, László; Halmosi, Róbert; Várady, Edit; Tóth, Kálmán; Battyáni, István

    2017-01-01

    Iodinated contrast media (Xenetix®, Ultravist®, Omnipaque®, Visipaque® and Iomeron®) used for computed tomography (CT) may decrease fibrinolysis by recombinant tissue plasminogen activator (rt-PA). We hypothesized that receiving iodinated contrast media before rt-PA may impair thrombolysis as measured by a new model system. Whole blood from Wistar Kyoto rats (n = 10) was obtained and allowed to form blood clots. Thrombolysis was performed by placing individually the prepared clots into 15 mL tubes and adding 5 mL saline buffer, 100μg rt-PA and a different contrast media; adjusting the quantity of iodine to either 30 mg or 60 mg. The thrombolytic efficacy was quantified by measuring the optical density (OD415) of the supernatant at different time points, namely at 0, 30, 60, and 90 min. There was a significant decrease in clot lysis efficiency observed in presence of iodine containing contrast media comparing to positive control group. Moreover, when the quantity of iodine was increased from 30 mg to 60 mg; the dissolution rate downturned with additional ∼50%. In conclusion, our study suggests that high dose of iodine potentially could negatively affect the efficiency of the thrombolytic therapy performed by rt-PA.

  16. Experience of slowly infused high-iodine-dose contrast computed tomography (SHD) of intracranial tumors

    International Nuclear Information System (INIS)

    Muraoka, Kiyoaki; Numata, Hideharu; Hokama, Yasuo

    1983-01-01

    A study was done on 20 patients with intracranial tumors by means of the slowly infused high-iodine-dose (SHD) contrast-enhancement technique. An intravenous drip infusion of 300 ml of Angiografin was given for three hours. Computerized tomograms were taken 1 hour, (2 hours), and 3 hours after the beginning of the drip infusion. The authors divided the lesions into four groups by analyzing the sequential changes in CT numbers using a histograms or profile of the region of interest. In group I, additional lesions were visible on the SHD scan (one case of metastatic brain tumors from lung cancer). In group 2, lesions were better displayed on the SHD scan due to increased enhancement (17 cases). In group 3, SHD scans showed no change (2 cases of fibrous astrocytoma). In group 4, the enhancement was diminished, but the lesion per se was still clealy identifiable (no case). Finally, in 18 cases out of 20 (90%), an additional or better display of the lesion was detected on SHD enhanced CT. The rational for doing the SHD enhancement is to detect a lesion with a minimally impaired blood-brain barrier by exposing a prolonged high blood-iodine level, and so the scanning is delayed until detectable levels of the contrast medium have accumulated within the vascular-channel pool or extravascular space of the lesion. SHD enhancement is useful: I) for revealing any additional lesion in a metastatic brain tumor; 2) for better displaying an obscure lesion on a usual scan; 3) for differentiating the quality of the lesion (for example, malignancy or cyst formation), and 4) for predicting the prognosis of the lesion. (J.P.N.)

  17. Accuracy of contrast-enhanced dual-energy MDCT for the assessment of iodine uptake in renal lesions.

    Science.gov (United States)

    Mileto, Achille; Marin, Daniele; Ramirez-Giraldo, Juan Carlos; Scribano, Emanuele; Krauss, Bernhard; Mazziotti, Silvio; Ascenti, Giorgio

    2014-05-01

    The objective of our study was to assess the accuracy of iodine-related attenuation and iodine quantification as imaging biomarkers of iodine uptake in renal lesions on a single-phase nephrographic image with dual-energy MDCT. Fifty-nine patients (41 men, 18 women; age range, 28-84 years) with 80 renal lesions underwent contrast-enhanced dual-energy CT during the nephrographic phase of enhancement. Renal lesions were characterized as enhancing or nonenhancing on color-coded iodine overlay maps using iodine-related attenuation (in Hounsfield units) and iodine quantification (in milligrams per milliliter). For iodine-related attenuation the iodine uptake thresholds of 15 and 20 HU were tested; a threshold of 0.5 mg/mL was used for iodine quantification. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of iodine-related attenuation and iodine quantification were calculated from chi-square tests of contingency with histopathology or imaging follow-up as the reference standard. The 95% CIs were calculated from binomial expression. Differences in sensitivity and specificity were assessed by means of McNemar analysis. A significant difference in sensitivity and specificity was found between iodine-related attenuation with the thresholds of 15 HU (sensitivity, 91.4%; specificity, 93.3%; PPV, 91.4%; NPV, 93.3%) and 20 HU (sensitivity, 77.1%; specificity, 100%; PPV, 100%; NPV, 84.9%) (p = 0.008) and between iodine quantification (sensitivity, 100%; specificity, 97.7%; PPV, 97.2%; NPV, 100%) and iodine-related attenuation with a threshold of 20 HU (p = 0.004). No significant difference in sensitivity and specificity was found between iodine quantification and iodine-related attenuation with a threshold of 15 HU. Contrast-enhanced dual-energy MDCT with iodine-related attenuation and iodine quantification allows accurate evaluation of iodine uptake in renal lesions on a single-phase nephrographic image.

  18. Influence of different iodinated contrast media on the induction of DNA double-strand breaks after in vitro X-ray irradiation.

    Science.gov (United States)

    Deinzer, Christoph K W; Danova, Daniela; Kleb, Beate; Klose, Klaus J; Heverhagen, Johannes T

    2014-01-01

    The objective of this work was to examine differences in DNA double-strand break induction in peripheral blood lymphocytes after in vitro X-ray irradiation between iodinated contrast agents. Four different iodinated X-ray contrast agents--three of them with two different iodine concentrations--and mannitol (negative control; concentration of 150 mg mannitol per ml blood) were pipetted into blood samples so that there was a concentration of 0, 7.5 or 15 mg of iodine per ml blood in the samples. Negative controls without contrast medium (0 mg of iodine per ml blood) were also processed for every irradiation dose. The tubes were exposed to 0, 20 or 500 mGy in vitro X-ray irradiation. After that, the lymphocytes were separated by using density-gradient centrifugation. Fluorescence microscopy was applied to determine the average number of γH2AX-foci per lymphocyte in the presence or absence of different contrast media or mannitol. Differences in the number of γH2AX-foci were statistically analysed by one-way ANOVA and post-hoc Tukey's honestly significant difference test. Iodinated contrast agents led to a statistically significant increase in DNA double-strand breaks after in vitro irradiation. This effect increased statistically significant with rising radiation dose and appeared independent of the contrast agent used (iopromid, iodixanol, iomeprol, iopamidol). A statistically significant difference in DNA damage between the different tested contrast agents was not found. Therefore, the increase in DNA double-strand breaks depends solely on the amount of iodine applied. For evaluation of clinical consequences, our findings could be tested in further animal studies. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Safe use of iodinated and gadolinium-based contrast media in current practice in Japan: a questionnaire survey.

    Science.gov (United States)

    Tsushima, Yoshito; Ishiguchi, Tsuneo; Murakami, Takamichi; Hayashi, Hiromitsu; Hayakawa, Katsumi; Fukuda, Kunihiko; Korogi, Yukunori; Sugimoto, Hideharu; Takehara, Yasuo; Narumi, Yoshifumi; Arai, Yasuaki; Kuwatsuru, Ryohei; Yoshimitsu, Kengo; Awai, Kazuo; Kanematsu, Masayuki; Takagi, Ryo

    2016-02-01

    To help establish consensus on the safe use of contrast media in Japan. Questionnaires were sent to accredited teaching hospitals with radiology residency programs. The reply rate was 45.4% (329/724). For contrast-induced nephropathy (CIN), chronic and acute kidney diseases were considered a risk factor in 96.7 and 93.6%, respectively, and dehydration in 73.9%. As preventive actions, intravenous hydration (89.1%) and reduction of iodinated contrast media dose (86.9%) were commonly performed. For nephrogenic systemic fibrosis (NSF), chronic and acute kidney diseases were considered risk factors in 98.5 and 90.6%, respectively, but use of unstable gadolinium-based contrast media was considered a risk factor in only 55.6%. A renal function test was always (63.5% in iodinated; 65.7% in gadolinium) or almost always (23.1; 19.8%) performed, and estimated glomerular filtration rate (eGFR) was the parameter most frequently used (80.8; 82.6%). For the patients with risk factors for acute adverse reaction (AAR), steroid premedication or/and change of contrast medium were frequent preventive actions, but intravenous steroid administration immediately before contrast media use was still performed. Our questionnaire survey revealed that preventive actions against CIN were properly performed based on patients' eGFR. Preventive actions against NSF and AAR still lacked consensus.

  20. Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml

    International Nuclear Information System (INIS)

    Behrendt, F.F.; Mahnken, A.H.; Keil, S.; Das, M.; Hohl, C.; Guenther, R.W.; Muehlenbruch, G.; Bauer, D.; Seidensticker, P.; Jost, E.; Wildberger, J.E.

    2008-01-01

    The purpose of this study was to intraindividually evaluate the difference in intraluminal vessel and parenchyma contrast enhancement of two different iodine concentrations in multidetector-row computed tomography (MDCT) of the abdomen. Eighty-three patients underwent baseline and follow-up MDCT-scanning (Somatom Sensation 16; Siemens, Forchheim, Germany) of the abdomen using contrast media containing 370 mg iodine/ml (protocol A; Ultravist 370, Bayer Schering Pharma, Berlin, Germany) and 300 mg iodine/ml (protocol B; Ultravist 300). The total iodine load (37 g iodine) and the iodine delivery rate (1.29 g iodine/s) were identical for both protocols. Contrast enhancement in the portal venous phase was measured in the abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney. Mean attenuation values were compared using paired t-test. Intraindividual comparison revealed no statistically significant differences of the mean attenuation values between protocols A and B for all anatomic sites: abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney (all P > 0.05). Given an injection protocol with constant total iodine load and constant iodine delivery rate, the iodine concentration of contrast media does not significantly influence abdominal contrast enhancement in the portal venous phase. (orig.)

  1. Iomeprol: results of clinical trials in children with a new nonionic contrast medium

    International Nuclear Information System (INIS)

    Gessel, R. van; Moeller, A.; Schmiedel, E.

    1994-01-01

    A total of 438 patients (1 day - 17 years) were enrolled in open-label phase III studies with Iomeprol in the most important radiologic, urologic, and cardiologic indications. Iomeprol was tested in five concentrations ranging from isotonic solutions of 150 mg iodine/ml up to 400 mg iodine/ml. Half of the patients were younger than 3 years. Apart from the mostly slight sensations of heat, pain, and taste, the following adverse events were observed independently of a causal relationship to the test compound: vomiting (1.8%), rise in blood pressure (1.8%), and restlessness (1.1%). The respective incidence of all other adverse events was below 1%. Iomeprol is a suitable and well-tolerated nonionic contrast medium for use in pediatric examinations. (orig./MG) [de

  2. Automated contrast medium monitoring system for computed tomography--Intra-institutional audit.

    Science.gov (United States)

    Lauretti, Dario Luca; Neri, Emanuele; Faggioni, Lorenzo; Paolicchi, Fabio; Caramella, Davide; Bartolozzi, Carlo

    2015-12-01

    The aim of this study was to analyze the usage and the data recorded by a RIS-PACS-connected contrast medium (CM) monitoring system (Certegra(®), Bayer Healthcare, Leverkusen, Germany) over 19 months of CT activity. The system used was connected to two dual syringe power injectors (each associated with a 16-row and a high definition 64-row multidetector CT scanner, respectively), allowing to manage contrast medium injection parameters and to send and retrieve CT study-related information via RIS/PACS for any scheduled contrast-enhanced CT examination. The system can handle up to 64 variables and can be accessed via touchscreen by CT operators as well as via a web interface by registered users with three different hierarchy levels. Data related to CM injection parameters (i.e. iodine concentration, volume and flow rate of CM, iodine delivery rate and iodine dose, CM injection pressure, and volume and flow rate of saline), patient weight and height, and type of CT study over a testing period spanning from 1 June 2013 to 10 January 2015 were retrieved from the system. Technical alerts occurred for each injection event (such as system disarm due to technical failure, disarm due to operator's stop, incomplete filling of patient data fields, or excessively high injection pressure), as well as interoperability issues related to data sending and receiving to/from the RIS/PACS were also recorded. During the testing period, the CM monitoring system generated a total of 8609 reports, of which 7629 relative to successful injection events (88.6%). 331 alerts were generated, of which 40 resulted in injection interruption and 291 in CM flow rate limitation due to excessively high injection pressure (>325 psi). Average CM volume and flow rate were 93.73 ± 17.58 mL and 3.53 ± 0.89 mL/s, and contrast injection pressure ranged between 5 and 167 psi. A statistically significant correlation was found between iodine concentration and peak IDR (rs=0.2744, psystems can provide a full

  3. Iodine

    Science.gov (United States)

    ... Health Information Supplement Fact Sheets Frequently Asked Questions Making Decisions What you Need To Know About Supplements Dietary ... mild iodine deficiency and of iodine supplements on cognitive ... breasts. It mainly affects women of reproductive age but can also occur ...

  4. Potential dependent superiority of gold nanoparticles in comparison to iodinated contrast agents

    International Nuclear Information System (INIS)

    Jackson, Price A.; Rahman, Wan Nordiana W. Abd.; Wong, Christopher J.; Ackerly, Trevor; Geso, Moshi

    2010-01-01

    Purpose: To identify the benefits in image contrast enhancement using gold nanoparticles (AuNPs) compared to conventional iodinated contrast media. Materials and methods: Gold nanoparticles and iodinated contrast media were evaluated for contrast enhancement at various X-ray tube potentials in an imaging phantom. Iopromide and AuNP suspension were equalized according to molar concentration of radiopaque element (0.5077 Mol/L). Contrast-to-noise ratio is used to quantify contrast enhancement. Both projectional radiographic (40-80 kVp) and computed tomography (CT) (80-140kVp) imaging modalities were examined. Results and conclusions: Findings indicate 89% improvement in CNR at low energies near the mammographic range (40 kVp). However, as expected no significant difference in enhancement was observed at potentials commonly used for angiography (around 80 kVp) probably due to the k-edge influence for iodine. At the highest energies typically available in computed tomography, significant improvement in contrast enhancement using gold nanoparticles is obtained, 114% greater CNR than that produced by iodine at 140 kVp. Experimental findings for 70-120 kVp spectra correlate well with the theoretical calculations based on linear attenuation coefficients. Superior attenuation of gold nanoparticles at low and high kVp potentials support their further (pre)clinical evaluation.

  5. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, N.G. [University of Otago, Department of Radiology, Christchurch (New Zealand); Butler, A.P. [University of Otago, Department of Radiology, Christchurch (New Zealand); University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Scott, N.J.A. [University of Otago, Department of Medicine, Christchurch (New Zealand); Cook, N.J. [Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Butzer, J.S. [Karlsruhe Institute of Technology, Physics Department, Karlsruhe (Germany); Schleich, N. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Firsching, M. [Friedrich Alexander University, Physics Department, Erlangen (Germany); Grasset, R.; Ruiter, N. de [University of Canterbury, Hitlab NZ, Christchurch (New Zealand); Campbell, M. [European Organisation for Nuclear Research, Physics Section, Geneva (Switzerland); Butler, P.H. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand)

    2010-09-15

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 {mu}A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at <55 {mu}m isotropic voxels. Spectral CT distinguishes contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications. (orig.)

  6. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.

    Science.gov (United States)

    Anderson, N G; Butler, A P; Scott, N J A; Cook, N J; Butzer, J S; Schleich, N; Firsching, M; Grasset, R; de Ruiter, N; Campbell, M; Butler, P H

    2010-09-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 microA). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications.

  7. Risk Stratification of iodine-induced thyrotoxicosis before contrast agent application

    International Nuclear Information System (INIS)

    Fricke, E.

    2004-01-01

    Today, examinations using iodine containing contrast media are rather frequent. Even though in modern contrast agents the content of free iodine is low, in vivo deiodination results in a non physiologic high iodine load of the thyroid gland. Whilst in normal thyroid tissue iodine metabolism and hormone production are self-regulating in spite of the variable iodine load, those mechanisms are disturbed in autonomous thyroid tissue. Clinical studies displayed low risk of iodine induced thyrotoxicosis after application of contrast agent. Nonetheless the clinician has to assess the risk of thyrotoxicosis for each individual patient and he has to decide how to cope with this risk. Thyroid scintigraphy using Tc-99m-pertechnetate with quantitative measurement of the thyroidal uptake (TcTU) has been shown to be a useful tool in this question, especially when performed under suppression of the non-autonomous tissue (TcTUs). In particular patients with pre-existing suppression of the TSH secretion should be selected for this investigation. Also at risk are elderly persons and those with diffuse or nodular goitres. In spite of the high frequency of contrast agent applications, data on scintigraphy for risk evaluation of thyrotoxicosis and on efficacy of prophylactic medication are scarce. Based on own results and on a review of literature, the risk of thyrotoxicosis seems to be negligible in patients with a TcTUs of less than 1% even in case of preexistent latent hyperthyroidism. If a suppressed TSH level is known and TcTUs is higher than 1%, prophylactic medication should be given. There is evidence for a combination therapy inhibiting both iodine uptake and metabolism, i.e. with perchlorate and thiamazole, being more efficient than monotherapy, particularly in patients with high risk of thyrotoxicosis. (orig.)

  8. Risk Stratification of iodine-induced thyrotoxicosis before contrast agent application; Prognosebeurteilung bei geplanter Kontrastmittelexposition

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, E. [Inst. fuer Molekulare Biophysik, Radiochemie und Nuklearmedizin, Herz- und Diabeteszentrum, Nordrheinwestfalen, Bad Oeynhausen (Germany)

    2004-06-01

    Today, examinations using iodine containing contrast media are rather frequent. Even though in modern contrast agents the content of free iodine is low, in vivo deiodination results in a non physiologic high iodine load of the thyroid gland. Whilst in normal thyroid tissue iodine metabolism and hormone production are self-regulating in spite of the variable iodine load, those mechanisms are disturbed in autonomous thyroid tissue. Clinical studies displayed low risk of iodine induced thyrotoxicosis after application of contrast agent. Nonetheless the clinician has to assess the risk of thyrotoxicosis for each individual patient and he has to decide how to cope with this risk. Thyroid scintigraphy using Tc-99m-pertechnetate with quantitative measurement of the thyroidal uptake (TcTU) has been shown to be a useful tool in this question, especially when performed under suppression of the non-autonomous tissue (TcTUs). In particular patients with pre-existing suppression of the TSH secretion should be selected for this investigation. Also at risk are elderly persons and those with diffuse or nodular goitres. In spite of the high frequency of contrast agent applications, data on scintigraphy for risk evaluation of thyrotoxicosis and on efficacy of prophylactic medication are scarce. Based on own results and on a review of literature, the risk of thyrotoxicosis seems to be negligible in patients with a TcTUs of less than 1% even in case of preexistent latent hyperthyroidism. If a suppressed TSH level is known and TcTUs is higher than 1%, prophylactic medication should be given. There is evidence for a combination therapy inhibiting both iodine uptake and metabolism, i.e. with perchlorate and thiamazole, being more efficient than monotherapy, particularly in patients with high risk of thyrotoxicosis. (orig.)

  9. Reducing the risk of iodine-based and MRI contrast media administration: Recommendation for a questionnaire at the time of booking

    International Nuclear Information System (INIS)

    Morcos, Sameh K.; Bellin, Marie-France; Thomsen, Henrik S.; Almen, Torsten; Aspelin, Peter; Heinz-Peer, Gertraud; Jakobsen, Jarl A.; Liss, Per; Oyen, Raymond; Stacul, Fulvio; Molen, Aart J. van der; Webb, Judith A.W.

    2008-01-01

    This paper presents a practical questionnaire to be used when a contrast medium examination is requested. The questionnaire is based on the guidelines from the European Society of Urogenital Radiology. Its aim is to identify patients at increased risk of clinically relevant renal and non-renal adverse reactions to iodine-based and MRI contrast agents. The questionnaire should be completed by the referring physician when the examination is requested

  10. Reducing the risk of iodine-based and MRI contrast media administration: Recommendation for a questionnaire at the time of booking

    Energy Technology Data Exchange (ETDEWEB)

    Morcos, Sameh K. [Department of Diagn. Imaging, Northern General Hospital, Herries Road, Sheffield S5 7AU (United Kingdom)], E-mail: sameh.morcos@sth.nhs.uk; Bellin, Marie-France [Service de Radiologie, Hopital Paul Brousse, 14 Av. Paul Vaillant Couturier, F-94800 Villejuif (France)], E-mail: marie-france.bellin@pbr.ap-hop-paris.fr; Thomsen, Henrik S. [Department of Diagnostic Radiology 54E2, Copenhagen University Hospital Herlev, Herlev Ringvej 75, DK-2730 Herlev (Denmark)], E-mail: hentho01@heh.regionh.dk; Almen, Torsten [Lybska Vaegen 10, S-239 40 Falsterbo (Sweden)], E-mail: torsten.almen@ta-contrast.se; Aspelin, Peter [Diagnostic Radiology, Huddinge University Hospital, S-141 86 Huddinge (Sweden)], E-mail: peter.aspelin@ki.se; Heinz-Peer, Gertraud [Department of Radiology, University Hospital Vienna, AKH, Wahringer Gurtel 18-20, A-1090 Vienna (Austria)], E-mail: gertraud.heinz@meduniwien.ac.at; Jakobsen, Jarl A. [Department of Radiology, Rikshospitalet, N-0027 Oslo (Norway)], E-mail: jarl.jakobsen@rikshospitalet.no; Liss, Per [Department of Radiology, Akademiska sjukhuset, SE-751 85 Uppsala (Sweden)], E-mail: per.liss@akademiska.se; Oyen, Raymond [Department of Radiology, University Hospital Gasthuisberg, Herestraat 46, B-3000 Leuven (Belgium)], E-mail: raymond.oyen@uzleuven.be; Stacul, Fulvio [Institute of Radiology, Ospedale di Cattinara, I-34149 Trieste (Italy)], E-mail: fulvio.stacul@aots.sanita.fvg.it; Molen, Aart J. van der [Department of Radiology, C2-S, Leiden University Medical center, P.O. Box 9600, NL-2300 RC Leiden (Netherlands)], E-mail: aart.vdmolen@planet.nl; Webb, Judith A.W. [3 Sellars Hall Close, Finchley, London N3 1JL (United Kingdom)], E-mail: jawwebb@btopenworld.com

    2008-05-15

    This paper presents a practical questionnaire to be used when a contrast medium examination is requested. The questionnaire is based on the guidelines from the European Society of Urogenital Radiology. Its aim is to identify patients at increased risk of clinically relevant renal and non-renal adverse reactions to iodine-based and MRI contrast agents. The questionnaire should be completed by the referring physician when the examination is requested.

  11. Iodinated Contrast Media-Induced Thyroid Dysfunction in Euthyroid Nodular Goiter Patients.

    Science.gov (United States)

    Kornelius, Edy; Chiou, Jeng-Yuan; Yang, Yi-Sun; Lo, Shih-Chang; Peng, Chiung-Huei; Lai, Yung-Rung; Huang, Chien-Ning

    2016-08-01

    The risks of thyroid dysfunction after iodinated contrast media exposure in patients with euthyroid nodular goiter are largely unknown. This observational, retrospective cohort study included a random selection of one million people in Taiwan. All patients with iodinated contrast media exposure during this study period were selected. Patients with euthyroid nodular goiter were identified as cases, while patients without thyroid nodule were selected as controls. We followed these patients until the first event of thyroid dysfunction including hyperthyroidism or hypothyroidism after iodinated contrast media exposure. A total of 334 cases and 2672 matched controls were selected in this study. The mean age of cases and controls were 58.6 and 58.4 years old, and mean follow-up durations were 2.1 and 2 years respectively. After adjustment, patients with euthyroid nodular goiter had a higher risk of thyroid dysfunction (hazard ratio 5.43, [confidence interval (CI) 3.01-9.80]) compared with controls after iodinated contrast media exposure. In the subgroup analysis, the risks of hyperthyroidism and hypothyroidism in cases compared with controls were 5.77 [CI 2.64-12.62] and 4.95 [CI 2.15-11.40] respectively. Half of the euthyroid nodular goiter cases developed thyroid dysfunction within one year after iodinated contrast media exposure. Interestingly, all thyroid-related comorbidities and drug prescriptions did not increase the risk of thyroid dysfunction. Presence of euthyroid nodular goiter was associated with higher risk of thyroid dysfunction including hyperthyroidism and hypothyroidism after iodinated contrast media exposure.

  12. SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Obeid, L; Esteve, F; Adam, J [Grenoble Institut des Neurosciences, La Tronche, Isere (France); Tessier, A; Balosso, J [Centre Hospitalier Universitaire, La Tronche, Isere (France)

    2014-06-15

    Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

  13. Comparison of excretory urographic contrast effects of dimeric and monomeric non-ionic iodinated contrast media in dogs

    International Nuclear Information System (INIS)

    Kishimoto, M.; Yamada, K.; Watanabe, A.; Miyamoto, K.; Iwasaki, T.; Miyake, Y.

    2007-01-01

    In excretory urography, the osmolarity of contrast media has rarely been treated as important in veterinary medicine. In this study, the contrast effect of two contrast media (monomeric iohexol and dimeric iodixanol) in the renal cortex and aorta were compared using computed tomography (CT). Five beagle dogs were used and the study employed a cross-over method for each contrast media. The results showed that there was no difference between the media in the aorta, but iodixanol showed higher CT value and a longer contrast effect than iohexol in the renal cortex, in spite of having the same iodine dosage. It is believed that iodixanol, with its low osmolarity, is diluted less by osmotic diuresis than monomeric iohexol. It is important to consider the osmolarity of the contrast media when evaluating the contrast effect, and it is essential to use the same contrast media for each examination, or the renal excretory speed will be under/overestimated

  14. Breakthrough reactions of iodinated and gadolinium contrast media after oral steroid premedication protocol.

    Science.gov (United States)

    Jingu, Akiko; Fukuda, Junya; Taketomi-Takahashi, Ayako; Tsushima, Yoshito

    2014-10-06

    Adverse reactions to iodinated and gadolinium contrast media are an important clinical issue. Although some guidelines have proposed oral steroid premedication protocols to prevent adverse reactions, some patients may have reactions to contrast media in spite of premedication (breakthrough reaction; BTR).The purpose of this study was to assess the frequency, type and severity of BTR when following an oral steroid premedication protocol. All iodinated and gadolinium contrast-enhanced radiologic examinations between August 2011 and February 2013 for which the premedication protocol was applied in our institution were assessed for BTRs. The protocol was applied to a total of 252 examinations (153 patients, ages 15-87 years; 63 males, 90 females). Of these, 152 were for prior acute adverse reactions to contrast media, 85 were for a history of bronchial asthma, and 15 were for other reasons. There were 198 contrast enhanced CTs and 54 contrast enhanced MRIs. There were nine BTR (4.5%) for iodinated contrast media, and only one BTR (1.9%) for gadolinium contrast media: eight were mild and one was moderate. No patient who had a mild index reaction (IR) had a severe BTR. Incidence of BTRs when following the premedication protocol was low. This study by no means proves the efficacy of premedication, but provides some support for following a premedication protocol to improve safety of contrast-enhanced examinations when prior adverse reactions are mild, or when there is a history of asthma.

  15. Breakthrough reactions of iodinated and gadolinium contrast media after oral steroid premedication protocol

    International Nuclear Information System (INIS)

    Jingu, Akiko; Fukuda, Junya; Taketomi-Takahashi, Ayako; Tsushima, Yoshito

    2014-01-01

    Adverse reactions to iodinated and gadolinium contrast media are an important clinical issue. Although some guidelines have proposed oral steroid premedication protocols to prevent adverse reactions, some patients may have reactions to contrast media in spite of premedication (breakthrough reaction; BTR). The purpose of this study was to assess the frequency, type and severity of BTR when following an oral steroid premedication protocol. All iodinated and gadolinium contrast-enhanced radiologic examinations between August 2011 and February 2013 for which the premedication protocol was applied in our institution were assessed for BTRs. The protocol was applied to a total of 252 examinations (153 patients, ages 15–87 years; 63 males, 90 females). Of these, 152 were for prior acute adverse reactions to contrast media, 85 were for a history of bronchial asthma, and 15 were for other reasons. There were 198 contrast enhanced CTs and 54 contrast enhanced MRIs. There were nine BTR (4.5%) for iodinated contrast media, and only one BTR (1.9%) for gadolinium contrast media: eight were mild and one was moderate. No patient who had a mild index reaction (IR) had a severe BTR. Incidence of BTRs when following the premedication protocol was low. This study by no means proves the efficacy of premedication, but provides some support for following a premedication protocol to improve safety of contrast-enhanced examinations when prior adverse reactions are mild, or when there is a history of asthma

  16. Anaphylactoid reactions to the nonvascular administration of water-soluble iodinated contrast media.

    Science.gov (United States)

    Davis, Peter L

    2015-06-01

    Anaphylactoidlike reactions occur during the nonvascular administration of iodinated contrast media. Many of these reactions have been severe. These reactions have occurred with many procedures, including gastrointestinal imaging, cystography, sialography, and hysterosalpingography. This article reviews reports of these reactions. It also reviews what the literature recommends concerning how to deal with individuals undergoing these procedures who are at a higher risk for anaphylactoidlike reactions.

  17. Outcome Differences between Intra-Arterial Iso- and Low-Osmolality Iodinated Radiographic Contrast Media in the Interventional Management of Stroke III Trial.

    Science.gov (United States)

    Tomsick, T A; Foster, L D; Liebeskind, D S; Hill, M D; Carrozella, J; Goyal, M; von Kummer, R; Demchuk, A M; Dzialowski, I; Puetz, V; Jovin, T; Morales, H; Palesch, Y Y; Broderick, J; Khatri, P; Yeatts, S D

    2015-11-01

    Intracarotid arterial infusion of nonionic, low-osmolal iohexol contrast medium has been associated with increased intracranial hemorrhage in a rat middle cerebral artery occlusion model compared with saline infusion. Iso-osmolal iodixanol (290 mOsm/kg H2O) infusion demonstrated smaller infarcts and less intracranial hemorrhage compared with low-osmolal iopamidol and saline. No studies comparing iodinated radiographic contrast media in human stroke have been performed, to our knowledge. We hypothesized that low-osmolal contrast media may be associated with worse outcomes compared with iodixanol in the Interventional Management of Stroke III Trial (IMS III). We reviewed prospective iodinated radiographic contrast media data for 133 M1 occlusions treated with endovascular therapy. We compared 5 prespecified efficacy and safety end points (mRS 0-2 outcome, modified TICI 2b-3 reperfusion, asymptomatic and symptomatic intracranial hemorrhage, and mortality) between those receiving iodixanol (n = 31) or low-osmolal contrast media (n = 102). Variables imbalanced between iodinated radiographic contrast media types or associated with outcome were considered potential covariates for the adjusted models. In addition to the iodinated radiographic contrast media type, final covariates were those selected by using the stepwise method in a logistic regression model. Adjusted relative risks were then estimated by using a log-link regression model. Of baseline or endovascular therapy variables potentially linked to outcome, prior antiplatelet agent use was more common and microcatheter iodinated radiographic contrast media injections were fewer with iodixanol. Relative risk point estimates are in favor of iodixanol for the 5 prespecified end points with M1 occlusion. The percentage of risk differences are numerically greater for microcatheter injections with iodixanol. While data favoring the use of iso-osmolal iodixanol for reperfusion of M1 occlusion following IV rtPA are

  18. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300)

    International Nuclear Information System (INIS)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D.

    2004-01-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  19. Study of the safety of a new non-ionic contrast medium, iopromide 370 in patients with chronic renal failure

    International Nuclear Information System (INIS)

    Meyrier, A.; Fernet, M.; Rainfray, M.

    1989-01-01

    Intravenous injection of iodinated contrast media usually induces modifications of renal function. Adverse effects of contrast media on renal function may affect diuresis, blood flow or glomerular filtration rate. These modifications are mainly related to osmolality but also chemotoxicity. This open study showed that after i.v. injection of a bolus of iopromide 370, a new non-ionic contrast medium, there was no untoward effect on renal function in patients with renal insufficiency. This justifies comparative studies in patients with renal impairment including elderly subjects, to confirm the tolerance of this product in high risk groups [fr

  20. Distribution and relevance of iodinated X-ray contrast media and iodinated trihalomethanes in an aquatic environment.

    Science.gov (United States)

    Xu, Zhifa; Li, Xia; Hu, Xialin; Yin, Daqiang

    2017-10-01

    Distribution and relevance of iodinated X-ray contrast media (ICM) and iodinated disinfection byproducts (I-DBPs) in a real aquatic environment have been rarely documented. In this paper, some ICM were proven to be strongly correlated with I-DBPs through investigation of five ICM and five iodinated trihalomethanes (I-THMs) in surface water and two drinking water treatment plants (DWTPs) of the Yangtze River Delta, China. The total ICM concentrations in Taihu Lake and the Huangpu River ranged from 88.7 to 131 ng L -1 and 102-252 ng L -1 , respectively. While the total I-THM concentrations ranged from 128 to 967 ng L -1 in Taihu Lake and 267-680 ng L -1 in the Huangpu River. Iohexol, the dominant ICM, showed significant positive correlation (p < 0.01) with CHClI 2 in Taihu Lake. Iopamidol and iomeprol correlated positively (p < 0.01) with some I-THMs in the Huangpu River. The observed pronounced correlations between ICM and I-THMs indicated that ICM play an important role in the formation of I-THMs in a real aquatic environment. Characteristics of the I-THM species distributions indicated that I-THMs may be transformed by natural conditions. Both DWTPs showed negligible removal efficiencies for total ICM (<20%). Strikingly high concentrations of total I-THMs were observed in the finished water (2848 ng L -1 in conventional DWTP and 356 ng L -1 in advanced DWTP). Obvious transformation of ICM to I-THMs was observed during the chlorination and ozonization processes in DWTPs. We suggest that ICM is an important source for I-DBP formation in the real aquatic environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Extravasation of contrast medium into the gastrointestinal tract following lymphangiography

    International Nuclear Information System (INIS)

    Mihara, K.; Koga, K.; Tsurudome, H.; Nakano, T.; Hoshi, H.; Yamada, H.; Kawahira, K.; Inakura, M.; Watanabe, K.; Haraguchi, Y.

    1981-01-01

    Two cases with roentgenologic findings of extravasation of contrast medium into the stomach and colon following lymphangiography are presented. One is clinically diagnosed as primary intestinal lymphangiectasia; the other as retroperitoneal spread from uterine cancer. The significance of lymphangiography in gastrointestinal or retroperitoneal disorders is discussed. (orig.)

  2. Extravasation of contrast medium into the gastrointestinal tract following lymphangiography

    Energy Technology Data Exchange (ETDEWEB)

    Mihara, K.; Koga, K.; Tsurudome, H.; Nakano, T.; Hoshi, H.; Yamada, H.; Kawahira, K.; Inakura, M.; Watanabe, K.; Haraguchi, Y.

    1981-07-15

    Two cases with roentgenologic findings of extravasation of contrast medium into the stomach and colon following lymphangiography are presented. One is clinically diagnosed as primary intestinal lymphangiectasia; the other as retroperitoneal spread from uterine cancer. The significance of lymphangiography in gastrointestinal or retroperitoneal disorders is discussed.

  3. Extravasation of contrast medium during CT examination: An ...

    African Journals Online (AJOL)

    2013-03-31

    Extravasation of contrast medium during CT examination: An observational casecontrol study. ... Methods: every incident of extravasation which occurred between March 2012 and March 31, 2013 was recorded in an extravasation form. Ethics Committee approval was obtained and the patients gave their consent to ...

  4. Potential mechanisms behind contrast medium-induced nephropathy

    African Journals Online (AJOL)

    How contrast medium-induced nephropathy (CIN) comes about is poorly understood, although CIN is a common cause of acute renal failure. Hitherto, the various studies performed have led to different interpretations and partially contradictory conclusions. This article aimed to review the mechanisms underlying CIN and to ...

  5. Targeting cancer chemotherapeutic agents by use of lipiodol contrast medium

    International Nuclear Information System (INIS)

    Konno, T.

    1990-01-01

    Arterially administered Lipiodol Ultrafluid contrast medium selectively remained in various malignant solid tumors because of the difference in time required for the removal of Lipiodol contrast medium from normal capillaries and tumor neovasculature. Although blood flow was maintained in the tumor, even immediately after injection Lipiodol contrast medium remained in the neovasculature of the tumor. To target anti-cancer agents to tumors by using Lipiodol contrast medium as a carrier, the characteristics of the agents were examined. Anti-cancer agents had to be soluble in Lipiodol, be stable in it, and separate gradually from it so that the anti-cancer agents would selectively remain in the tumor. These conditions were found to be necessary on the basis of the measurement of radioactivity in VX2 tumors implanted in the liver of 16 rabbits that received arterial injections of 14C-labeled doxorubicin. Antitumor activities and side effects of arterial injections of two types of anti-cancer agents were compared in 76 rabbits with VX2 tumors. Oily anti-cancer agents that had characteristics essential for targeting were compared with simple mixtures of anti-cancer agents with Lipiodol contrast medium that did not have these essential characteristics. Groups of rabbits that received oily anti-cancer agents responded significantly better than groups that received simple mixtures, and side effects were observed more frequently in the groups that received the simple mixtures. These results suggest that targeting of the anti-cancer agent to the tumor is important for treatment of solid malignant tumors

  6. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    CERN Document Server

    Anderson, NG; Firsching, M; de Ruiter, N; Schleich, N; Butzer, J S; Cook, N J; Grasset, R; Campbell, M; Scott, N J A; Anderson, N G

    2010-01-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 A mu A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct f...

  7. Iodine

    Science.gov (United States)

    ... leg ulcers and reduce the chance of a future infection. Conjunctivitis (pinkeye). Research suggests that using eye ... National Institute of Medicine has set Adequate Intake (AI) of iodine for infants: 0 to 6 months, ...

  8. [Comparison of iodinated and barium-containing contrast media of different viscosity in the detection of pharyngeal perforation].

    Science.gov (United States)

    Keberle, M; Wittenberg, G; Trusen, A; Baumgartner, W; Hahn, D

    2001-08-01

    In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous than the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose.

  9. A simple method to estimate the optimum iodine concentration of contrast material through microcatheters: hydrodynamic calculation with spreadsheet software

    International Nuclear Information System (INIS)

    Yamauchi, Teiyu; Hayashi, Toshihiko; Yamada, Takeshi; Futami, Choichiro; Tsukiyama, Yumiko; Harada, Motoko; Furui, Shigeru; Suzuki, Shigeru; Mimura, Kohshiro

    2008-01-01

    It is important to increase the iodine delivery rate (I), that is the iodine concentration of the contrast material (C) x the flow rate of the contrast material (Q), through microcatheters to obtain arteriograms of the highest contrast. It is known that C is an important factor that influences I. The purpose of this study is to establish a method of hydrodynamic calculation of the optimum iodine concentration (i.e., the iodine concentration at which I becomes maximum) of the contrast material and its flow rate through commercially available microcatheters. Iopamidol, ioversol and iohexol of ten iodine concentrations were used. Iodine delivery rates (I meas) of each contrast material through ten microcatheters were measured. The calculated iodine delivery rate (I cal) and calculated optimum iodine concentration (calculated C opt) were obtained with spreadsheet software. The agreement between I cal and I meas was studied by correlation and logarithmic Bland-Altman analyses. The value of the calculated C opt was within the optimum range of iodine concentrations (i.e. the range of iodine concentrations at which I meas becomes 90% or more of the maximum) in all cases. A good correlation between I cal and I meas (I cal = 1.08 I meas, r = 0.99) was observed. Logarithmic Bland-Altman analysis showed that the 95% confidence interval of I cal/I meas was between 0.82 and 1.29. In conclusion, hydrodynamic calculation with spreadsheet software is an accurate, generally applicable and cost-saving method to estimate the value of the optimum iodine concentration and its flow rate through microcatheters

  10. Iopamidol, a new non-ionic X-ray contrast medium

    International Nuclear Information System (INIS)

    Hagen, B.

    1982-01-01

    Iopamidol, a new non-ionic, monomeric contrast medium with low osmolality has been well established in our angiographic routine procedures according to the favourable results obtained in more than 300 controlled trials. The general tolerance (demonstrated by the rate of systemic adverse reactions) of the lower concentrated solution (300 mg iodine/ml is a little bit better than that of the higher concentrated one (370 mg iodine/ml). We could demonstrate a significant difference between the two preparations related to local side effects such as pain and heat sensations. The results of 100 intraindividual double blind studies (only peripheral angiography) specially referred to local side effects showed the high significant decrease of pain and heat sensations after application of Iopamidol compared to the results gained by the ionic Ioxitalamate and Ioglicinate. There was no remarkable difference between Iopamidol and Ioxaglate which is a dimeric but likewise low osmolar substance. The role of osmolality in the generation of side effects is pointed out. In consequence the advantages of using contrast media of reducted osmolality particularly in peripheral angiography must be emphasized. (orig.)

  11. Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions

    International Nuclear Information System (INIS)

    Froeling, Vera; Diekmann, Felix; Renz, Diane M.; Fallenberg, Eva M.; Steffen, Ingo G.; Diekmann, Susanne; Schmitzberger, Florian F.; Lawaczeck, Ruediger

    2013-01-01

    Assessment of contrast agent kinetics in contrast-enhanced MRI (CE-MRI) with gadolinium-containing contrast agents offers the opportunity to predict breast lesion malignancy. The goal of our study was to determine if similar patterns exist for spectral contrast-enhanced digital breast tomosynthesis (CE-DBT) using an iodinated contrast agent. The protocol of our prospective study was approved by the relevant institutional review board and the German Federal Office for Radiation Protection. All patients provided written informed consent. We included 21 women with a mean age of 62.4 years. All underwent ultrasound-guided biopsy of a suspect breast lesion, spectral CE-DBT and CE-MRI. For every breast lesion, contrast agent kinetics was assessed by signal intensity-time curves for spectral CE-DBT and CE-MRI. Statistical comparison used Cohen's kappa and Spearman's rho test. Spearman's rho of 0.49 showed significant (P = 0.036) correlation regarding the contrast agent kinetics in signal intensity-time curves for spectral CE-DBT and CE-MRI. Cohen's kappa indicated moderate agreement (kappa = 0.438). There is a statistically significant correlation between contrast agent kinetics in the signal intensity-time curves for spectral CE-DBT and CE-MRI. Observing intralesional contrast agent kinetics in spectral CE-DBT may aid evaluation of malignant breast lesions. (orig.)

  12. An experimental study on renal damage induced by ionic contrast media in relation to iodine concentration

    International Nuclear Information System (INIS)

    Sung, Dong Wook; Yoon, Yup; Lim, Jae Hoon; Yang, Moon Ho

    1990-01-01

    Renal injury caused by iodinated contrast media has been widely known, but there has been few papers regarding the pathological change. A series of kidneys after injection of iodinated contrast media was examined to document pathological change. A total of 80 rats was divided into two groups; those given Urografin-60% by 5ml/kg; those given Urografin-76% by 5ml/kg. The kidneys were removed out 1, 2, 3, 5, 7, 10, 14 and 21 days after injection of contrast media and microscopically examined. The resulted were as follows: 1. Pathological changes induced by ionic contrast media were deposition of proteinaceous materials in the proximal convoluted tubules, congestion of interstitial vessels, and vasa rectae, and epithelial degeneration of collecting ducts. There was no detectable pathological changes in the glomerulus, loop of Henle, and distal convoluted tubules. 2. All pathological changes were severe, as the concentration of contrast media increased. 3. These pathologic changes appeared 1 day after injection of contrast media and persisted at least 3 weeks without improvement. Author concludes that the renal damage induced by ionic contrast media becomes severe with increase in concentration, and pathologic changes are not influence with time interval

  13. The prevention of anaphylactoid reactions to iodinated radiological contrast media: a systematic review

    Directory of Open Access Journals (Sweden)

    Carter Andrew

    2006-04-01

    Full Text Available Abstract Background Anaphylactoid reactions to iodinated contrast media are relatively common and potentially life threatening. Opinion is divided as to the utility of medications for preventing these reactions. We performed a systematic review to assess regimes for the prevention of anaphylactoid reactions to iodinated contrast media. Methods Searches for studies were conducted in the Medline, EMBASE, CINAHL and CENTRAL databases. Bibliographies of included studies and review articles were examined and experts were contacted. Randomised clinical trials that examined agents given prior to iodinated contrast material for the prevention of anaphylactoid reactions were included in the review. The validity of the included studies was examined using a component approach. Results Six studies met the inclusion criteria, but only one of these fulfilled all of the validity criteria. There were four studies that examined the use of H1 antihistamines, each was used to prevent anaphylactoid reactions to ionic contrast. The random effects pooled relative risk demonstrated a significant reduction in the overall rate of anaphylactoid reactions (RR = 0.4, 95% CI 0.18-0.9, p = 0.027. There were insufficient studies to produce a pooled statistic for the use of corticosteroids, however regimes of steroids (methylprednisolone 32 mg given at least six hours and again two hours prior to the administration of contrast suggested a reduction in the incidence of anaphylactoid reactions. Conclusion In conclusion, there are few high quality randomised clinical trials that have addressed the question of the optimal methods to prevent allergic type reactions to iodinated radiological contrast media. Allowing for these limitations, the results suggest that H1 antihistamines given immediately prior to the administration of ionic contrast may be useful in preventing reactions to ionic contrast and are suggestive of a protective effect of corticosteroids when given in two doses

  14. Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    International Nuclear Information System (INIS)

    Berther, Ralph; Eckhardt, Boris; Zollikofer, Christoph L.; Patak, Michael A.; Erturk, Sukru M.

    2008-01-01

    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P<0.001), homogeneity of the luminal content (P<0.001), delineation of the bowel-wall to the lumen (P<0.001) and to the mesentery (P<0.001) and artifacts (P<0.001), leading to a significant better overall image quality (P<0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P<0.001) and wall to lumen delineation (P<0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population. (orig.)

  15. Influence of iodinated contrast media on the activities of histamine inactivating enzymes diamine oxidase and histamine N-methyltransferase in vitro.

    Science.gov (United States)

    Kuefner, M A; Feurle, J; Petersen, J; Uder, M; Schwelberger, H G

    2014-01-01

    Iodinated contrast media can cause pseudoallergic reactions associated with histamine release in significant numbers of patients. To clarify whether these adverse reactions may be aggravated by a compromised histamine catabolism we asked if radiographic contrast agents in vitro inhibit the histamine inactivating enzymes diamine oxidase (DAO) and histamine N-methyltransferase (HMT). Nine iodinated contrast agents were tested in vitro. Following pre-incubation of purified porcine kidney DAO and recombinant human HMT with 0.1-10mM of the respective contrast medium (H2O and specific inhibitors of DAO and HMT as controls) enzyme activities were determined by using radiometric micro assays. None of the contrast media irrespective of their structure showed significant inhibition of the activities of DAO and HMT. Pre-incubation of the enzymes with specific inhibitors led to complete inhibition of the respective enzymatic activity. The iodinated contrast media tested in vitro did not exhibit inhibition of histamine converting enzymes at physiologically relevant concentrations. However due to the in vitro character of this study these results do not directly reflect the in vivo situation. Copyright © 2012 SEICAP. Published by Elsevier Espana. All rights reserved.

  16. Torsten Almén (1931-2016): the father of non-ionic iodine contrast media.

    Science.gov (United States)

    Nyman, Ulf; Ekberg, Olle; Aspelin, Peter

    2016-09-01

    The Swedish radiologist Torsten Almén is the first clinical radiologist ever to have made a fundamental contribution to intravascular contrast medium design, the development of non-ionic contrast media. He became emotionally triggered by the patients' severe pain each time he injected the ionic "high-osmolar" contrast media when performing peripheral arteriographies in the early 1960s. One day he got a flash of genius that combined the observation of pain, a pathophysiological theory and how to eliminate it with suitable contrast media chemistry. After self-studies in chemistry he developed the concept of iodine contrast media not dissociating into ions in solution to reduce their osmolality and even reach plasma isotonicity. He offered several pharmaceutical companies his concept of mono- and polymeric non-ionic agents but without response, since it was considered against the chemical laws of that time. Contrast media constructed as salts and dissociating into ions in solution was regarded an absolute necessity to achieve high enough water solubility and concentration for diagnostic purposes. Finally a small Norwegian company, Nyegaard & Co., took up his idea 1968 and together they developed the essentially painless "low-osmolar" monomeric non-ionic metrizamide (Amipaque) released in 1974 and iohexol (Omipaque) in 1982 followed by the "iso-osmolar" dimeric non-ionic iodixanol (Visipaque) released in 1993. This has implied a profound paradigm shift with regard to reduction of both hypertonic and chemotoxic side effects, which have been a prerequisite for the today's widespread use of contrast medium-enhanced CT and advanced endovascular interventional techniques even in fragile patients. © The Foundation Acta Radiologica 2016.

  17. Gadolinium-DTPA and gadodiamide as an alternative contrast medium for CT

    International Nuclear Information System (INIS)

    Engelbrecht, V.; Koch, J.A.; Rassek, M.; Moedder, U.

    1996-01-01

    To evaluate the effect of intravenously applied gadolinium-based contrast medium in computed tomographic (CT) studies. Serial dilutions of iohexol 300, Gd-DTPA and gadodiamide were scanned with CT in a phantom study using water filled tubes. For quantification of X-ray attenuation, the mean Hounsfield units (HU) were calculated from the CT scans. Five patients with contraindications against iodine contrast agents were examined with abdominal or thoracic CT before and after application of 0.2 mmol/kg body weight of a gadolinium-based contrast agent. In these patients attenuation values were obtained in ROI from unenhanced and enhanced CT scans. The phantom study revealed a 38,4% enhancement for Gd-DTPA and a 35.7% enhancement for gadodiamide scaled on the reference measurements with iohexol 300. Thus, 130.2 ml Gd-DTPA or 140.1 ml gadodiamide are needed to achieve the same attenuation as an i.v. injection of 50 ml iohexol 300. Consequently the corresponding dose of 1 mmol/kg body weight would exceed the manufacturer's recommended dose. In four patients with complete thoracic or abdominal CT, i.v. applied gadolinium-based contrast medium (0.2 mmol/kg) yielded no visible advantage. In these patients parenchymal enhancement did not exceed 25%. Dynamic CT of a patient with focal liver lesion revealed an arterial enhancement peak of 75%. Sufficient parenchymal enhancement in CT studies cannot be achieved with the available gadolinium-based contrast mediums. They might be helpful if only short time vascular enhancement is required. (orig.) [de

  18. Prophylaxis and treatment of side effects due to iodinated contrast media relevant to radiological practice

    International Nuclear Information System (INIS)

    Becker, C.

    2007-01-01

    Increased utilization of iodinated contrast media may be associated with increased incidence of adverse events. The most important side effects include contrast-induced nephropathy, anaphylactoid reaction, thyrotoxicosis, and extravasation. In patients with moderate renal dysfunction, saline hydration and reduction of contrast media volume are recommended. No regime to prevent anaphylactoid reactions has yet proven to be efficient. If subclinical hyperthyroidism has been determined, prophylaxis with sodium perchlorate is advised. Contrast-induced nephropathy is commonly transient and needs to be followed over time. Mild general anaphylactoid reactions may be treated with antihistaminic drugs and corticosteroids. Furthermore the choice of the X-ray contrast media might influence the risk of any adverse effects. (orig.) [de

  19. Use of gadolinium chelate to confirm epidural needle placement in patients with an iodinated contrast reaction

    International Nuclear Information System (INIS)

    Shetty, Sanjay K.; Nelson, Erik N.; Lawrimore, Tara M.; Palmer, William E.

    2007-01-01

    When performing epidural steroid injections for the management of chronic back pain, imaging guidance and a limited epidurogram improve accuracy of needle placement and ensure appropriate delivery of the injectate into the epidural space. We describe our experience using a gadolinium chelate as an alternative contrast agent for limited epidurography in patients with a history of an iodinated contrast reaction. Thirty-eight of 2,067 (1.8%) epidural steroid injections performed in our department over a 25-month period (December 2003-January 2006) employed gadolinium. All injections were performed in the lumbar spine employing a paramedian interlaminar approach. Procedural notes and patient charts were reviewed to evaluate for immediate or delayed complications related to incorrect intrathecal or intravascular needle placement. A retrospective analysis of selected fluoroscopic spot images was performed to evaluate confidence of epidural needle placement; this analysis compared these spot images against those obtained from age- and gender-matched control patients in whom iodinated contrast was used to confirm needle placement. Real-time fluoroscopic guidance permitted confident visualization of an epidurogram at the time of procedure in all 38 cases as documented in the procedural report, and no procedure resulted in a complication due to incorrect needle placement. Retrospective review of fluoroscopic spot images revealed at least moderate confidence of epidural needle placement by both readers in 29/38 cases (76.3%). Fluoroscopic spot images obtained using gadolinium yielded significantly less confidence than images obtained in control patients whose procedures were performed using iodinated contrast (P < 0.01). However, operators were sufficiently confident in needle placement based on real-time fluoroscopic images (not available in our subsequent review) to inject anesthestic in all 38 cases, despite the immediate consequences that could result from intrathecal

  20. Use of gadolinium chelate to confirm epidural needle placement in patients with an iodinated contrast reaction

    Energy Technology Data Exchange (ETDEWEB)

    Shetty, Sanjay K. [Massachusetts General Hospital, Harvard Medical School, Division of Musculoskeletal Radiology, Department of Radiology, Boston, MA (United States); Beth Israel Deaconess Medical Center, Harvard Medical School, Department of Radiology, Boston, MA (United States); Nelson, Erik N.; Lawrimore, Tara M.; Palmer, William E. [Massachusetts General Hospital, Harvard Medical School, Division of Musculoskeletal Radiology, Department of Radiology, Boston, MA (United States)

    2007-04-15

    When performing epidural steroid injections for the management of chronic back pain, imaging guidance and a limited epidurogram improve accuracy of needle placement and ensure appropriate delivery of the injectate into the epidural space. We describe our experience using a gadolinium chelate as an alternative contrast agent for limited epidurography in patients with a history of an iodinated contrast reaction. Thirty-eight of 2,067 (1.8%) epidural steroid injections performed in our department over a 25-month period (December 2003-January 2006) employed gadolinium. All injections were performed in the lumbar spine employing a paramedian interlaminar approach. Procedural notes and patient charts were reviewed to evaluate for immediate or delayed complications related to incorrect intrathecal or intravascular needle placement. A retrospective analysis of selected fluoroscopic spot images was performed to evaluate confidence of epidural needle placement; this analysis compared these spot images against those obtained from age- and gender-matched control patients in whom iodinated contrast was used to confirm needle placement. Real-time fluoroscopic guidance permitted confident visualization of an epidurogram at the time of procedure in all 38 cases as documented in the procedural report, and no procedure resulted in a complication due to incorrect needle placement. Retrospective review of fluoroscopic spot images revealed at least moderate confidence of epidural needle placement by both readers in 29/38 cases (76.3%). Fluoroscopic spot images obtained using gadolinium yielded significantly less confidence than images obtained in control patients whose procedures were performed using iodinated contrast (P < 0.01). However, operators were sufficiently confident in needle placement based on real-time fluoroscopic images (not available in our subsequent review) to inject anesthestic in all 38 cases, despite the immediate consequences that could result from intrathecal

  1. Iodinated Contrast Does Not Alter Clotting Dynamics in Acute Ischemic Stroke as Measured by Thromboelastography

    Science.gov (United States)

    McDonald, Mark M; Archeval-Lao, Joancy M; Cai, Chunyan; Peng, Hui; Sangha, Navdeep; Parker, Stephanie A; Wetzel, Jeremy; Riney, Stephen A; Cherches, Matt F; Guthrie, Greer J; Roper, Tiffany C; Kawano-Castillo, Jorge F; Pandurengan, Renga; Rahbar, Mohammad H; Grotta, James C

    2014-01-01

    Background and Purpose Iodinated contrast agents used for computed tomography angiography (CTA) may alter fibrin fiber characteristics and decrease fibrinolysis by tissue plasminogen activator (tPA). Thromboelastography (TEG™) measures the dynamics of coagulation and correlates with thrombolysis in acute ischemic stroke (AIS) patients. We hypothesized that receiving CTA prior to tPA will not impair thrombolysis as measured by TEG™. Methods AIS patients receiving 0.9 mg/kg tPA within 4.5 hours of symptom onset were prospectively enrolled. For CTA, 350 mg/dL of iohexol or 320 mg/dL of iodixanol at a dose of 2.2 ml/kg was administered. TEG™ was measured prior to tPA and 10-minutes after tPA bolus. CTA timing was left to the discretion of the treating physician. Results Of 136 AIS patients who received tPA, 47 had CTA prior to tPA bolus, and 42 had either CTA following tPA and post-tPA TEG™ draw or no CTA (non-contrast group). The median change in clot lysis (LY30) following tPA was 95.3% in the contrast group vs. 95.0% in the non-contrast group (p = 0.74). Thus, tPA-induced thrombolysis did not differ between contrast and non-contrast groups. Additionally, there was no effect of contrast on any pre-tPA TEG™ value. Conclusions Our data do not support an effect of iodinated contrast agents on clot formation or tPA activity. PMID:24370757

  2. Computed tomography lung iodine contrast mapping by image registration and subtraction

    Science.gov (United States)

    Goatman, Keith; Plakas, Costas; Schuijf, Joanne; Beveridge, Erin; Prokop, Mathias

    2014-03-01

    Pulmonary embolism (PE) is a relatively common and potentially life threatening disease, affecting around 600,000 people annually in the United States alone. Prompt treatment using anticoagulants is effective and saves lives, but unnecessary treatment risks life threatening haemorrhage. The specificity of any diagnostic test for PE is therefore as important as its sensitivity. Computed tomography (CT) angiography is routinely used to diagnose PE. However, there are concerns it may over-report the condition. Additional information about the severity of an occlusion can be obtained from an iodine contrast map that represents tissue perfusion. Such maps tend to be derived from dual-energy CT acquisitions. However, they may also be calculated by subtracting pre- and post-contrast CT scans. Indeed, there are technical advantages to such a subtraction approach, including better contrast-to-noise ratio for the same radiation dose, and bone suppression. However, subtraction relies on accurate image registration. This paper presents a framework for the automatic alignment of pre- and post-contrast lung volumes prior to subtraction. The registration accuracy is evaluated for seven subjects for whom pre- and post-contrast helical CT scans were acquired using a Toshiba Aquilion ONE scanner. One hundred corresponding points were annotated on the pre- and post-contrast scans, distributed throughout the lung volume. Surface-to-surface error distances were also calculated from lung segmentations. Prior to registration the mean Euclidean landmark alignment error was 2.57mm (range 1.43-4.34 mm), and following registration the mean error was 0.54mm (range 0.44-0.64 mm). The mean surface error distance was 1.89mm before registration and 0.47mm after registration. There was a commensurate reduction in visual artefacts following registration. In conclusion, a framework for pre- and post-contrast lung registration has been developed that is sufficiently accurate for lung subtraction

  3. Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Jo, K.I.; Kim, S.R.; Choi, J.H.; Kim, K.H.; Jeon, P. [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of)

    2015-11-15

    Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution. A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm{sup 3}/s (n = 3) and 0.2 cm{sup 3}/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries. Flow velocities changed -15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm{sup 3}/s contrast infusion protocol was better for evaluating the stent and host artery. Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow. (orig.)

  4. Photodecomposition of iodinated contrast media and subsequent formation of toxic iodinated moieties during final disinfection with chlorinated oxidants.

    Science.gov (United States)

    Allard, Sébastien; Criquet, Justine; Prunier, Anaïs; Falantin, Cécilia; Le Person, Annaïg; Yat-Man Tang, Janet; Croué, Jean-Philippe

    2016-10-15

    Large amount of iodinated contrast media (ICM) are found in natural waters (up to μg.L(-)(1) levels) due to their worldwide use in medical imaging and their poor removal by conventional wastewater treatment. Synthetic water samples containing different ICM and natural organic matter (NOM) extracts were subjected to UV254 irradiation followed by the addition of chlorine (HOCl) or chloramine (NH2Cl) to simulate final disinfection. In this study, two new quantum yields were determined for diatrizoic acid (0.071 mol.Einstein(-1)) and iotalamic acid (0.038 mol.Einstein(-1)) while values for iopromide (IOP) (0.039 mol.Einstein(-1)), iopamidol (0.034 mol.Einstein(-1)) and iohexol (0.041 mol.Einstein(-1)) were consistent with published data. The photodegradation of IOP led to an increasing release of iodide with increasing UV doses. Iodide is oxidized to hypoiodous acid (HOI) either by HOCl or NH2Cl. In presence of NOM, the addition of oxidant increased the formation of iodinated disinfection by-products (I-DBPs). On one hand, when the concentration of HOCl was increased, the formation of I-DBPs decreased since HOI was converted to iodate. On the other hand, when NH2Cl was used the formation of I-DBPs was constant for all concentration since HOI reacted only with NOM to form I-DBPs. Increasing the NOM concentration has two effects, it decreased the photodegradation of IOP by screening effect but it increased the number of reactive sites available for reaction with HOI. For experiments carried out with HOCl, increasing the NOM concentration led to a lower formation of I-DBPs since less IOP are photodegraded and iodate are formed. For NH2Cl the lower photodegradation of IOP is compensated by the higher amount of NOM reactive sites, therefore, I-DBPs concentrations were constant for all NOM concentrations. 7 different NOM extracts were tested and almost no differences in IOP degradation and I-DBPs formation was observed. Similar behaviour was observed for the 5 ICM

  5. Are referring clinicians aware of patients at risk from intravenous injection of iodinated contrast media?

    International Nuclear Information System (INIS)

    Konen, Eli; Konen, Osnat; Katz, Miriam; Levy, Yair; Rozenman, Judith; Hertz, Marjorie

    2002-01-01

    AIM: The purpose of our study was to assess the level of awareness of referring clinicians to populations at risk for complications of intravascular administration of iodinated contrast media. SUBJECTS AND METHODS: Two hundred and three physicians from three university hospitals completed an anonymous questionnaire regarding risk factors and contraindications to the intravenous administration of iodinated contrast media. The questionnaire included medical conditions with increased risk for anaphylactoid reaction (asthma, hay fever and food allergy) as well as chemotoxic (ischaemic heart disease, phaeochromocytoma and myasthenia gravis) adverse reactions, some with dependence on renal function (metformin treatment, diabetes mellitus and multiple myeloma). Two additional multiple-choice questions addressed pre-medication protocols and risk of nephrotoxicity in diabetic patients. RESULTS: Asthma, food allergy and hay fever were recognized as risk factors by 81·3%, 77·8% and 61·6% of respondents respectively, while ischaemic heart disease, phaeochromocytoma and myasthenia gravis were defined as such only by 9·8%, 30·0% and 28·6% respectively. Metformin treatment, diabetes mellitus and multiple myeloma, in the presence of normal renal function, were considered as risk factors by 46·3%, 38·9% and 58·1% of respondents respectively. One of the generally accepted pre-medication protocols was selected by 89·8%. The risk of nephrotoxicity in a diabetic patient was correctly assessed by 63·5% of respondents. CONCLUSION: We found a relatively high awareness among referring clinicians of a potential anaphylactoid reaction and nephrotoxicity due to iodinated contrast media. However, additional chemotoxic adverse reactions are less well known. Future efforts to improve communication between clinicians and radiologists should be focused in this direction. Konen, E. et al. (2002)

  6. Iodinated contrast media electro-degradation: process performance and degradation pathways.

    Science.gov (United States)

    Del Moro, Guido; Pastore, Carlo; Di Iaconi, Claudio; Mascolo, Giuseppe

    2015-02-15

    The electrochemical degradation of six of the most widely used iodinated contrast media was investigated. Batch experiments were performed under constant current conditions using two DSA® electrodes (titanium coated with a proprietary and patented mixed metal oxide solution of precious metals such as iridium, ruthenium, platinum, rhodium and tantalum). The degradation removal never fell below 85% (at a current density of 64 mA/cm(2) with a reaction time of 150 min) when perchlorate was used as the supporting electrolyte; however, when sulphate was used, the degradation performance was above 80% (at a current density of 64 mA/cm(2) with a reaction time of 150 min) for all of the compounds studied. Three main degradation pathways were identified, namely, the reductive de-iodination of the aromatic ring, the reduction of alkyl aromatic amides to simple amides and the de-acylation of N-aromatic amides to produce aromatic amines. However, as amidotrizoate is an aromatic carboxylate, this is added via the decarboxylation reaction. The investigation did not reveal toxicity except for the lower current density used, which has shown a modest toxicity, most likely for some reaction intermediates that are not further degraded. In order to obtain total removal of the contrast media, it was necessary to employ a current intensity between 118 and 182 mA/cm(2) with energy consumption higher than 370 kWh/m(3). Overall, the electrochemical degradation was revealed to be a reliable process for the treatment of iodinated contrast media that can be found in contaminated waters such as hospital wastewater or pharmaceutical waste-contaminated streams. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Are referring clinicians aware of patients at risk from intravenous injection of iodinated contrast media?

    Energy Technology Data Exchange (ETDEWEB)

    Konen, Eli; Konen, Osnat; Katz, Miriam; Levy, Yair; Rozenman, Judith; Hertz, Marjorie

    2002-02-01

    AIM: The purpose of our study was to assess the level of awareness of referring clinicians to populations at risk for complications of intravascular administration of iodinated contrast media. SUBJECTS AND METHODS: Two hundred and three physicians from three university hospitals completed an anonymous questionnaire regarding risk factors and contraindications to the intravenous administration of iodinated contrast media. The questionnaire included medical conditions with increased risk for anaphylactoid reaction (asthma, hay fever and food allergy) as well as chemotoxic (ischaemic heart disease, phaeochromocytoma and myasthenia gravis) adverse reactions, some with dependence on renal function (metformin treatment, diabetes mellitus and multiple myeloma). Two additional multiple-choice questions addressed pre-medication protocols and risk of nephrotoxicity in diabetic patients. RESULTS: Asthma, food allergy and hay fever were recognized as risk factors by 81{center_dot}3%, 77{center_dot}8% and 61{center_dot}6% of respondents respectively, while ischaemic heart disease, phaeochromocytoma and myasthenia gravis were defined as such only by 9{center_dot}8%, 30{center_dot}0% and 28{center_dot}6% respectively. Metformin treatment, diabetes mellitus and multiple myeloma, in the presence of normal renal function, were considered as risk factors by 46{center_dot}3%, 38{center_dot}9% and 58{center_dot}1% of respondents respectively. One of the generally accepted pre-medication protocols was selected by 89{center_dot}8%. The risk of nephrotoxicity in a diabetic patient was correctly assessed by 63{center_dot}5% of respondents. CONCLUSION: We found a relatively high awareness among referring clinicians of a potential anaphylactoid reaction and nephrotoxicity due to iodinated contrast media. However, additional chemotoxic adverse reactions are less well known. Future efforts to improve communication between clinicians and radiologists should be focused in this direction. Konen

  8. Non-ionic iodinated contrast media related immediate reactions: A mechanism study of 27 patients.

    Science.gov (United States)

    Zhai, Liqin; Guo, Xiangjie; Zhang, Haoyue; Jin, Qianqian; Zeng, Qiang; Tang, Xiaoxian; Gao, Cairong

    2017-01-01

    The underlying mechanism of non-ionic iodinated contrast media-related immediate reactions was evaluated in this study. Patients presenting at least grade II immediate reactions after non-ionic iodinated contrast media injection were enrolled. Basophil activation was evaluated by flow cytometry. The plasma concentration of human terminal complement complex SC5b-9, as well as concentrations of serum chymase, tryptase, human mast cell carboxypeptidase A3, human prostaglandin D2, and total IgE were measured by enzyme-linked immunosorbent assay. The basophil activation percentage was significantly higher in the study group than in the control group (17.94±21.06% vs 3.45±1.49%). The plasma concentration of human terminal complement complex SC5b-9 and concentrations of serum chymase, human mast cell carboxypeptidase A3, prostaglandin D2, tryptase, and total IgE were also significantly increased (236.99±318.21 vs 49.70±30.41ng/mL, 0.41±0.49 vs 0.09±0.06ng/mL, 1.17±0.67 vs 0.30±0.17ng/mL, 203.52±137.27 vs 102.28±48.72pg/mL, 3.81±0.22 vs 2.70±0.16ng/mL, 102.00±51.84 vs 19.97±2.75ng/mL, respectively). Both mast cells and basophils were activated in non-ionic iodinated contrast media to mediate immediate hypersensitivity, and mast cells may be involved. Different mechanisms, including IgE-dependent, complement-dependent, and direct membrane effects, contributed to mast cell and basophil activation. Individual patients may use a single or combined mechanism involving single or combined mast cells and basophils. Immediate reactions following non-ionic iodinated contrast media injection may be a mechanically heterogenous disease. Copyright © 2016. Published by Elsevier B.V.

  9. Reducing the risk of iodine-based and MRI contrast media administration: Recommendation for a questionnaire at the time of booking

    DEFF Research Database (Denmark)

    Morcos, S.K.; Bellin, M.F.; Almen, T.

    2008-01-01

    This paper presents a practical questionnaire to be used when a contrast medium examination is requested. The questionnaire is based on the guidelines from the European Society of Urogenital Radiology. Its aim is to identify patients at increased risk of clinically relevant renal and non-renal ad......-renal adverse reactions to iodine-based and MRI contrast agents. The questionnaire should be completed by the referring physician when the examination is requested. (C) 2008 Elsevier Ireland Ltd. All rights reserved Udgivelsesdato: 2008/5......This paper presents a practical questionnaire to be used when a contrast medium examination is requested. The questionnaire is based on the guidelines from the European Society of Urogenital Radiology. Its aim is to identify patients at increased risk of clinically relevant renal and non...

  10. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is an x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  11. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  12. Which iodinated contrast media is the least cytotoxic to human disc cells?

    Science.gov (United States)

    Kim, Kyung-Hyun; Park, Jeong-Yoon; Park, Hyo-Suk; Kuh, Sung-Uk; Chin, Dong-Kyu; Kim, Keun-Su; Cho, Yong-Eun

    2015-05-01

    Iodinated contrast media (CM) is commonly used for various intradiscal injections such as in discography and endoscopic spinal surgery. However, CM has been shown to be toxic to renal tissue due to its ionic strength and osmolarity and as a result of iodine-induced cytotoxicity, which has raised concern over whether there are similar negative effects on disc cells. This in vitro study was designed to identify the least cytotoxic iodinated CM to the human disc cell among four different physiochemical iodinated contrast dyes. In vitro laboratory study. Intervertebral disc tissue was obtained by discectomy from a total of 10 lumbar disc patients undergoing surgery and disc cells were isolated. The human disc cells were grown in 3D alginate bead culture with 0, 0.1, 10, and 100 mg/mL CM solutions (ionic dimer, ionic monomer, non-ionic dimer, and non-ionic monomer) and mannitol as a control for 2 days. The living cells were analyzed with trypan blue staining. Fluorescence-activated cell sorting analysis was performed using Annexin V and propidium iodide (PI) and 3D alginate bead immunostaining to identify live, apoptotic, and necrotic cells. Human disc cell death was time- and dose-dependent in response to CM and more necrosis was observed than apoptosis. In addition, non-ionic dimeric CM (iodixanol) showed the least toxic effect on human disc cells, followed by non-ionic monomeric (iopromide), ionic dimeric (ioxaglate), and ionic monomeric CM (ioxithalamate). Contrast media is cytotoxic to human disc cells in a dose- and time-dependent manner. This in vitro study revealed that, among four different CM preparations, non-ionic dimeric CM is the least detrimental to human disc cell viability. Careful attention should be paid to the type of CM chosen for discography and endoscopic spinal surgery. It is also necessary to investigate the detrimental effects of CM on disc cells and disc degeneration in further in vivo studies. Copyright © 2015 Elsevier Inc. All rights

  13. Human pharmacokinetics of iohexol. A new nonionic contrast medium

    International Nuclear Information System (INIS)

    Olsson, B.; Aulie, A.; Sveen, K.; Andrew, E.

    1983-01-01

    The pharmacokinetics of iohexol, a new nonionic, water-soluble contrast medium, have been determined after intravenous injection in 20 healthy volunteers, at four different dose levels (125-500 mg I/kg). The apparent volume of distribution was 0.27 1/kg, indicating distribution in the extracellular water. The biologic half-life was 121 minutes, comparable with that of other intravascular contrast media. Iohexol was excreted completely unmetabolized in the urine, with a 100% recovery 24 hours after injection. A comparison of iohexol and chromium-51 ( 51 Cr)-EDTA clearances indicates that iohexol is mainly excreted by glomerular filtration. The 51 Cr-EDTA clearance was the same when injected separately and concomitantly with iohexol, indicating that glomerular filtration rate is not affected by iohexol. No dose dependency was observed in the investigated parameters t1/2 alpha, t1/2 beta, Vd, ClT or ClR. Iohexol pharmacokinetics are in correspondence with previously reported data on intravascular contrast media

  14. Microvascular resistance in response to iodinated contrast media in normal and functionally impaired kidneys.

    Science.gov (United States)

    Kurihara, Osamu; Takano, Masamichi; Uchiyama, Saori; Fukuizumi, Isamu; Shimura, Tetsuro; Matsushita, Masato; Komiyama, Hidenori; Inami, Toru; Murakami, Daisuke; Munakata, Ryo; Ohba, Takayoshi; Hata, Noritake; Seino, Yoshihiko; Shimizu, Wataru

    2015-12-01

    Contrast-induced nephropathy (CIN) is considered to result from intrarenal vasoconstriction, and occurs more frequently in impaired than in normal kidneys. It was hypothesized that iodinated contrast media would markedly change renal blood flow and vascular resistance in functionally impaired kidneys. Thirty-six patients were enrolled (32 men; mean age, 75.3 ± 7.6 years) undergoing diagnostic coronary angiography and were divided into two groups based on the presence of chronic kidney disease (CKD), defined as an estimated glomerular filtration rate (eGFR) of contrast media. The APV and the RI were positively and inversely correlated with the eGFR at baseline, respectively (APV, R = 0.545, P = 0.001; RI, R = -0.627, P contrast media administration in the non-CKD group, but not in the CKD group (APV, P = 0.258; RI, P = 0.707). Although renal arterial resistance was higher in patients with CKD, it was not affected by contrast media administration, suggesting that patients with CKD could have an attenuated response to contrast media. © 2015 The Authors. Clinical and Experimental Pharmacology and Physiology Published by Wiley Publishing Asia Pty Ltd.

  15. Acute anterior myocardial infarction seen on conventional iodine-contrast CT

    Directory of Open Access Journals (Sweden)

    Christian Hagdrup, MD

    2017-09-01

    Full Text Available Diagnosis of acute myocardial infarction (AMI is based on clinical symptoms of chest pain and dyspnea in combination with electrocardiographic changes and a raise in myocardial-specific biomarkers. Imaging is by echocardiography and magnetic resonance. The preferred technique for identification of previous myocardial infarction (MI is magnetic resonance imaging with late gadolinium technique, but in the acute patient echocardiography is applied. In selected cases, important information can be obtained from other imaging modalities. We describe a case of a patient first suspected of an abdominal catastrophe in whom acute MI was diagnosed from a computerized tomography (CT scan with iodine contrast. Our case together with a few other cases reported in the literature demonstrate that contrast enhancement of the myocardium can be important to follow in the acute patient because the CT scans sometimes give a unique opportunity to recognize findings consistent with MI even though the CT scan was performed for another reason.

  16. Myelography iodinated contrast media. I. Unraveling the atropisomerism properties in solution.

    Science.gov (United States)

    Fontanive, Luca; D'Amelio, Nicola; Cesàro, Attilio; Gamini, Amelia; Tavagnacco, Letizia; Paolantoni, Marco; Brady, John W; Maiocchi, Alessandro; Uggeri, Fulvio

    2015-06-01

    The present work reports a thorough conformational analysis of iodinated contrast media: iomeprol, iopamidol (the world's most utilized contrast agent), and iopromide. Its main aim is the understanding of the complex structural features of these atropisomeric molecules, characterized by the presence of many conformers with hindered rotations, and of the role of atropisomerism in the physicochemical properties of their aqueous solutions. The problem was tackled by using an extensive analysis of (13)C NMR data on the solutions of whole molecules and of simple precursors in addition to FT-IR investigation and molecular simulations. This analysis demonstrated that out of the many possible atropisomers, only a few are significantly populated, and their relative population is provided. The conformational analysis also indicated that the presence of a sterically hindered amidic bond, allowing a significant population of cis forms (E in iopromide and exo in iomeprol), may be the basis for an increased thermodynamic solubility of concentrated solutions of iomeprol.

  17. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study

    Directory of Open Access Journals (Sweden)

    Yvana Lopes Pinheiro da Silva

    2015-04-01

    Full Text Available Objective: To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods: Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results: As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion: Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

  18. Changes in Renal Function in Elderly Patients Following Intravenous Iodinated Contrast Administration: A Retrospective Study

    International Nuclear Information System (INIS)

    Alsafi, A.; Alsafi, Z.; Lakhani, A.; Strickland, N.H.

    2014-01-01

    Contrast-induced nephropathy (CIN) is a recognised complication of intravascular administration of iodinated contrast media (ICM). Previous studies suggest a higher incidence in the elderly, but no large study has assessed this to date. We set out to assess changes in creatinine in elderly inpatients following computed tomography (CT) examination and compare those who received intravenous contrast to those who did not. Methods. Using the Radiology Information System in two teaching hospitals, inpatients over the age of seventy who had a CT examination and a baseline creatinine were identified and their follow-up creatinine levels were analysed. Elderly inpatients who underwent a non contrast CT over the same period were used as controls. Results. 677 elderly inpatients who received ICM were compared with 487 controls. 9.2% of patients who received ICM developed acute kidney injury (AKI) compared to 3.5% of inpatient controls (Ρ<0.0001). Patients with higher baseline eGFR had a higher incidence of post-CT AKI. Conclusions. The incidence of post-CT AKI is higher in patients who received IV ICM compared to those who did not; the difference may be partly attributable to contrast-induced nephropathy. This suggests that the incidence of CIN in the elderly may not be as high as previously thought.

  19. Body surface area adapted iopromide 300 mg/ml versus 370 mg/ml contrast medium injection protocol: Influence on quantitative and clinical assessment in combined PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Apitzsch, Jonas [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Lensing, Carina [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Müllerstrasse 178, 13353 Berlin (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-12-01

    Purpose: To investigate the quantitative and qualitative differences between combined positron emission tomography and computed X-ray tomography (PET/CT) enhanced with contrast medium with either an iodine concentration 300 mg/ml or 370 mg/ml. Materials and methods: 120 consecutive patients scheduled for F-18-Fluorodeoxyglucose (FDG) PET/CT were included. The first (second) 60 patients received contrast medium with 300 (370) mg iodine/ml. Intravenous injection protocols were adapted for an identical iodine delivery rate (1.3 mg/s) and body surface area (BSA) adapted iodine dose (22.26 g I/m{sup 2}). Maximum and mean standardized uptake values (SUV{sub max}; SUV{sub mean}) and contrast enhancement (HU) were determined in the ascending aorta, the abdominal aorta, the inferior vena cava, the portal vein, the liver and the right kidney in the venous contrast medium phase. PET data were evaluated visually for the presence of malignancy and image quality. Results: Both media caused significantly higher values for HU, SUV{sub mean} and SUV{sub max} for the enhanced PET/CT than the non-enhanced one (all p < 0.01). There were no significant differences in the degree of increase of HU, SUV{sub mean} and SUV{sub max} between the two contrast media at any anatomic site (all p > 0.05). Visual evaluation of lesions showed no differences between contrast and non-contrast PET/CT or between the two different contrast media (p = 0.77). Conclusion: When using a constant iodine delivery rate and total iodine dose in a BSA adapted injection protocol, there are no quantitative or qualitative differences in either CT or PET between contrast media with an iodine concentration of 300 mg/ml and 370 mg/ml, respectively.

  20. Effects of iodinated contrast media on renal function in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Jacob, H.M.

    1980-01-01

    Case histories of 89 patients with definite myoloma of the years 1959 to 1974 were investigated in a retrospective study. 41 intravenous urographies were carried out in 31 of these patients. There was no correlation between deterioration of the renal function and contrast medium application. Relevant literature on the subject has been compiled. By 1979, 19 case studies and 5 general studies had been published which have been summarized in tables in the present study. Analyses of these case histories have shown that acute renal failure was often due to other causes and not to contrast medium application. If these cases are left out of account 8 cases remain in which lethal renal failure occurred after intravenous urography of myeloma patients. The diiodinated contrast media formerly used was less well tolerated than the present triiodinated contrast media. Further risk factors were dehydratation and/or abdominal compression. Both measures are no longer employed in intravenous urography. (orig./MG) [de

  1. Myelography in the dog with non-ionic contrast media at different iodine concentrations

    International Nuclear Information System (INIS)

    Fatone, G.; Lamagna, F.; Pasolini, M.P.; Potena, A.; Brunetti, A.

    1997-01-01

    Image quality and side effects were evaluated retrospectively in a series of 183 myelographic studies performed with two non-ionic contrast media (iohexol and iopamidol) at different concentrations. Side effects during and following the procedure were recorded. Image quality was assessed using an arbitrary scoring system and statistical analysis was performed with the cross-tabulation test (4 times 2 table) by comparing two groups receiving contrast medium at higher and lower concentrations. No significant differences in side effects were observed between the two groups but the ratings for image quality were significantly higher in the group receiving contrast medium at the higher concentration than in the group receiving the lower concentration. The results suggest that a high concentration of non-ionic contrast media can safely be used in dogs and may improve image quality

  2. SU-G-IeP2-12: The Effect of Iterative Reconstruction and CT Tube Voltage On Hounsfield Unit Values of Iodinated Contrast

    Energy Technology Data Exchange (ETDEWEB)

    Ogden, K; Greene-Donnelly, K; Vallabhaneni, D; Scalzetti, E [SUNY Upstate Medical University, Syracuse, New York (United States)

    2016-06-15

    Purpose: To investigate the effects of changing iterative reconstruction strength and tube voltage on Hounsfield Unit (HU) values of varying concentrations of Iodinated contrast medium in a phantom. Method: Iodinated contrast (Omnipaque 300, GE Healthcare, Princeton NJ) was diluted with distilled water to concentrations of 0.6, 0.9, 1.8, 3.6, 7.2, and 10.8 mg/mL of Iodine. The solutions were scanned in a patient equivalent water phantom on two MDCT scanners: VCT 64 slice (GE Medical Systems, Waukesha, WI) and an Aquilion One 320 slice scanner (Toshiba America Medical Systems, Tustin CA). The phantom was scanned at 80, 100, 120, 140 kV using 400, 255, 180, and 130 mAs, respectively, for the VCT scanner, and 80, 100, 120, and 135 kV using 400, 250, 200, and 150 mAs, respectively, on the Aquilion One. Images were reconstructed at 2.5 mm (VCT) and 0.5 mm (Aquilion One). The VCT images were reconstructed using Advanced Statistical Iterative Reconstruction (ASIR) at 6 different strengths: 0%, 20%, 40%, 60%, 80%, and 100%. Aquilion One images were reconstructed using Adaptive Iterative Dose Reduction (AIDR) at 4 strengths: no AIDR, Weak AIDR, Standard AIDR, and Strong AIDR. Regions of interest (ROIs) were drawn on the images to measure the HU values and standard deviations of the diluted contrast. Second order polynomials were used to fit the HU values as a function of Iodine concentration. Results: For both scanners, there was no significant effect of changing the iterative reconstruction strength. The polynomial fits yielded goodness-of-fit (R2) values averaging 0.997. Conclusion: Changing the strength of the iterative reconstruction has no significant effect on the HU values of Iodinated contrast in a tissue-equivalent phantom. Fit values of HU vs Iodine concentration are useful in quantitative imaging protocols such as the determination of cardiac output from time-density curves in the main pulmonary artery.

  3. Bowel Angioedema Associated With Iodinated Contrast Media: Incidence and Predisposing Factors.

    Science.gov (United States)

    Seo, Nieun; Chung, Yong Eun; Lim, Joon Seok; Song, Mi Kyung; Kim, Myeong-Jin; Kim, Ki Whang

    2017-09-01

    Bowel angioedema is an acute adverse reaction to iodinated contrast media (CM) that involves the gastrointestinal tract. We aimed to investigate the incidence and predisposing factors of iodinated CM-associated bowel angioedema during computed tomography (CT) examinations. This study was approved by our institutional review board, and informed consent was waived due to its retrospective design. From July 2013 to July 2015, adult patients with a history of adverse reactions to iodinated CM during CT (group A, n = 427) and patients without adverse reactions matched for age and sex with the propensity-score matching method (group B, n = 427) were studied. Contrast media-associated bowel angioedema was determined when bowel wall thickness increased after contrast enhancement compared with the precontrast scan. Potential predisposing factors including patient demographics, symptoms and time of adverse reactions, and CM-related factors were compared between patients with and without angioedema in group A. In addition, the incidence of bowel angioedema was compared between groups A and B. The incidence of CM-associated bowel angioedema in group A was 3.3% (14/427) in the per-patient analysis and 2.6% (15/578) in the per-examination analysis. The CM-associated bowel angioedema involved the distal duodenum and/or proximal jejunum and showed long-segmental circumferential bowel wall thickening on CT. None of the studied predisposing factors was different between patients with and without bowel angioedema (P > 0.05). The incidence of CM-associated bowel angioedema in group B was 1.9% (8/427) and 1.7% (8/458) for per-patient and per-examination analyses, respectively, and these rates were not significantly different between groups A and B (P = 0.346 and P = 0.370, respectively). The incidence of CM-associated bowel angioedema during CT was 1.7% to 3.3%, and none of the studied predisposing factors was associated with bowel angioedema.

  4. Hepatic contrast medium enhancement at computed tomography and its correlation with various body size measures

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Nouhad, Jallo; Cederlund, Kerstin; Aspelin, Peter; Torkel, Brismar B., E-mail: anders.svensson@karolinska.se [Dept. of Clinical Science, Intervention and Technology at Karolinska Inst., Div. of Medical Imaging and Technology, Stockholm (Sweden); (Dept. of Radiology, Karolinska Univ. Hospital, Huddinge, Stockholm (Sweden)); Nyman, Ulf (Dept. of Diagnostic Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, Jonas (Competence Centre for Clinical Research, Skaane Univ. Hospital, Lund (Sweden)

    2012-07-15

    Background. When the same dose of iodine is given to all patients when performing abdominal computed tomography (CT) there may be a wide inter-individual variation in contrast medium (CM) enhancement of the liver. Purpose. To evaluate if any of the measures body height (BH), body mass index (BMI), lean body mass (LBM), ideal body weight (IBW), and body surface area (BSA) correlated better than body weight (BW) with hepatic enhancement, and to compare the enhancement when using iodixanol and iomeprol. Material and Methods. One hundred patients referred for standard three-phase CT examination of abdomen were enrolled. Body weight and height were measured at the time of the CT examination. Forty grams of iodine (iodixanol 320 mg I/mL or iomeprol 400 mg I/mL) was injected at a rate of 1.6 g-I/s, followed by a 50 mL saline flush. The late arterial phase was determined by using a semi-automatic smart prep technique with a scan delay of 20 s. The hepatic parenchymal phase started automatically 25 s after the late arterial phase. CM concentration was estimated by placement of regions of interest in aorta (native and late arterial phase) and in liver (native and parenchymal phase). Results. BW (r -0.51 and -0.64), LBM (r = -0.54 and -0.59), and BSA (r -0.54 and -0.65) showed the best correlation coefficients with aortic and hepatic parenchymal enhancement, respectively, without any significant differences between the measures. Comparing iodixanol and iomeprol there was no significant difference in aortic enhancement. The liver enhancement was significantly higher (P < 0.05) using iodixanol than iomeprol. Conclusion. To achieve a consistent hepatic enhancement, CM dose may simply be adjusted to body weight instead of using more complicated calculated parameters based on both weight and height.

  5. Contrast-enhanced voiding urosonography phantom study: intravenous iodinated and gadolinium-based contrast agents may cause false-negative results in assessment of vesicoureteral reflux in children

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Sauer, Alexander; Gassenmaier, Tobias; Petritsch, Bernhard; Herz, Stefan; Blanke, Philipp; Bley, Thorsten A.; Wirth, Clemens; Derlin, Thorsten

    2015-01-01

    Contrast-enhanced voiding urosonography (ce-VUS) is commonly requested simultaneously to other diagnostic imaging necessitating intravenous contrast agents. To date there is limited knowldedge about intravesical interactions between different types of contrast agents. To assess the effect of excreted intravenous iodinated and gadolinium-based contrast agents on the intravesical distribution of ultrasound contrast within contrast-enhanced voiding urosonography. Iodinated (iomeprol, iopamidol) and gadolinium-based (gadoterate meglumine) contrast agents were diluted to bladder concentration and injected into balloons filled with saline solution. CT scans were performed to assess the contrast distribution in these phantoms. Regions of interest were placed at the top and bottom side of each balloon and Hounsfield units (HU) were measured. Three other balloons were filled with saline solution and contrast media likewise. The ultrasound contrast agent sulphur hexafluoride was added and its distribution was assessed using sonography. MDCT scans showed a separation of two liquid layers in all bladder phantoms with the contrast layers located at the bottom and the saline solution at the top. Significant differences of the HU measurements at the top and bottom side were observed (P < 0.001-0.007). Following injection of ultrasound contrast agent, US showed its distribution exclusively among the saline solution. False-negative results of contrast-enhanced voiding urosonography may occur if it is performed shortly after imaging procedures requiring intravenous contrast. (orig.)

  6. Acceptability of oral iodinated contrast media: a head-to-head comparison of four media

    Science.gov (United States)

    Ngan-Soo, E; McCoubrie, P

    2013-01-01

    Objective: To assess the palatability of iodinated oral contrast media commonly used in abdominopelvic CT and CT colonography (CTC). Methods: 80 volunteers assessed the palatability of a 20-ml sample of a standard 30 mg ml−1 dilution of Omnipaque® (iohexol; GE Healthcare, Cork, Ireland), Telebrix® (meglumine ioxithalamate; Guerbet, Aulnay-sous-Bois, France), Gastromiro® (iopamidol; Bracco, High Wycombe, UK) and Gastrografin® (sodium diatrizoate and meglumine diatrizoate; Bayer, Newbury, UK) in a computer-generated random order. Results: Gastrografin is rated significantly less palatable than the remaining media (pcontrast media than both Gastromiro and Gastrografin, which has potential implications in compliance with both abdominopelvic CT and CTC. PMID:23564884

  7. Patient radiation dose during fluoroscopy testes with contrast medium

    International Nuclear Information System (INIS)

    Darsalih, Abir Abdelrady El noor

    2016-09-01

    The purpose of this study was to assess the patient radiation dose received in fluoroscopy examinations during contrast medium. The cumulative air kerma (Ck), kerma area product (KAP) and fluoroscopy time were measured for sixty ( male and female ) patients undergoing five fluoroscopy examinations KAP metre which was installed for the purpose of this study. The mean kerma area product were found to be 2.681, 5.1561, 9.85529. 5.7974 and 13.09 Gy.cm"2 for HSG, A.S and D.S, GI Track and sonogram tests, respectively. The obtained mean cumulative dose was were 6.31, 13.88, 24.61, 22.56 and 32.14 mGy for HSG, A.S, A.S and D.S , GI Track, respectively, the mean fluoroscopy time were. 0.18, 0.51,0.89,1.57 and 1.75 min, for HSG, A.S, A.S, and D.S, G1 Track and sonogram test respectively. Patient dose is mainly dependent on the patient size, procedure, equipment used exposure factor and user experience. As KV and mA were controlled by the AEC and it was found to be well calibrated, possible optimization could be achieved by radiologist by decreasing the exposure time if possible. (Author)

  8. Improve identification of details in double-contrast examination of the stomach by means of a new contrast medium mixture

    International Nuclear Information System (INIS)

    Tenner, R.

    1984-01-01

    In a contrast medium study, 100 patients were employed for a comparison between the contrast medium Mikropaque liquid and a mixture of Mikropaque HD and Mikropaque liquid in double-contrast examination of the stomach. The special feature of this method was that one and the same stomach was examined in each case with both contrast media. The new contrast media mixture with Mikropaque HD represents a step forward; the contrast could be enhanced in 80% of the cases, and the finely contoured relief became visible in two-thirds of the cases, compared with one-third of the examined patients before this method was introduced. (orig.) [de

  9. Impact of Iodinated Contrast on Renal Function and Hemodynamics in Rats with Chronic Hyperglycemia and Chronic Kidney Disease

    Science.gov (United States)

    Fernandes, Sheila Marques; Martins, Daniel Malisani; da Fonseca, Cassiane Dezoti; Watanabe, Mirian; Vattimo, Maria de Fátima Fernandes

    2016-01-01

    Iodinated contrast (IC) is clinically used in diagnostic and interventional procedures, but its use can result in contrast-induced acute kidney injury (CI-AKI). Chronic kidney disease (CKD) and chronic hyperglycemia (CH) are important predisposing factors to CI-AKI. The aim of this study was to investigate the impact of iodinated contrast on the renal function and hemodynamics in rats with chronic hyperglycemia and chronic kidney disease. A total of 30 rats were divided into six groups; Sham: control of chronic renal disease; Citrate: control of chronic hyperglycemia (CH); Nx5/6: rats with 5/6 nephrectomy; Chronic Hyperglycemia: rats receiving Streptozotocin 65 mg/kg; Nx5/6 + IC: rats Nx5/6 received 6 mL/kg of IC; CH + IC: Chronic hyperglycemia rats receiving 6 mL/kg of IC. Renal function (inulin clearance; urinary neutrophil gelatinase-associated lipocalin, NGAL) and hemodynamics (arterial blood pressure; renal blood flow; renal vascular resistance) were evaluated. Iodinated contrast significantly increased urinary NGAL and reduced inulin clearance, while the hemodynamics parameters showed changes in arterial blood pressure, renal blood flow, and renal vascular resistance in both CKD and CH groups. The results suggest that the iodinated contrast in risk factors models has important impact on renal function and hemodynamics. NGAL was confirmed to play a role of highlight in diagnosis of CI-AKI. PMID:27034930

  10. Impact of Iodinated Contrast on Renal Function and Hemodynamics in Rats with Chronic Hyperglycemia and Chronic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Sheila Marques Fernandes

    2016-01-01

    Full Text Available Iodinated contrast (IC is clinically used in diagnostic and interventional procedures, but its use can result in contrast-induced acute kidney injury (CI-AKI. Chronic kidney disease (CKD and chronic hyperglycemia (CH are important predisposing factors to CI-AKI. The aim of this study was to investigate the impact of iodinated contrast on the renal function and hemodynamics in rats with chronic hyperglycemia and chronic kidney disease. A total of 30 rats were divided into six groups; Sham: control of chronic renal disease; Citrate: control of chronic hyperglycemia (CH; Nx5/6: rats with 5/6 nephrectomy; Chronic Hyperglycemia: rats receiving Streptozotocin 65 mg/kg; Nx5/6 + IC: rats Nx5/6 received 6 mL/kg of IC; CH + IC: Chronic hyperglycemia rats receiving 6 mL/kg of IC. Renal function (inulin clearance; urinary neutrophil gelatinase-associated lipocalin, NGAL and hemodynamics (arterial blood pressure; renal blood flow; renal vascular resistance were evaluated. Iodinated contrast significantly increased urinary NGAL and reduced inulin clearance, while the hemodynamics parameters showed changes in arterial blood pressure, renal blood flow, and renal vascular resistance in both CKD and CH groups. The results suggest that the iodinated contrast in risk factors models has important impact on renal function and hemodynamics. NGAL was confirmed to play a role of highlight in diagnosis of CI-AKI.

  11. Persistent neurological deficit from iodinated contrast encephalopathy following intracranial aneurysm coiling. A case report and review of the literature.

    LENUS (Irish Health Repository)

    Leong, S

    2012-03-01

    Neurotoxicity from iodinated contrast agents is a known but rare complication of angiography and neurovascular intervention. Neurotoxicity results from contrast penetrating the blood-brain barrier with resultant cerebral oedema and altered neuronal excitability. Clinical effects include encephalopathy, seizures, cortical blindness and focal neurological deficits. Contrast induced encephalopathy is extensively reported as a transient and reversible phenomenon. We describe a patient with a persistent motor deficit due to an encephalopathy from iodinated contrast media administered during cerebral aneurysm coiling. This observation and a review of the literature highlights that contrast-induced encephalopathy may not always have a benign outcome and can cause permanent deficits. This potential harmful effect should be recognised by the angiographer and the interventionalist.

  12. Reduced iodinated contrast media for abdominal imaging by dual-layer spectral detector computed tomography for patients with kidney disease

    Directory of Open Access Journals (Sweden)

    Hirokazu Saito, MD

    2018-04-01

    Full Text Available Contrast-enhanced computed tomography using iodinated contrast media is useful for diagnosis of gastrointestinal diseases. However, contrast-induced nephropathy remains problematic for kidney diseases patients. Although current guidelines recommended the use of a minimal dose of contrast media necessary to obtain adequate images for diagnosis, obtaining adequate images with sufficient contrast enhancement is difficult with conventional computed tomography using reduced contrast media. Dual-layer spectral detector computed tomography enables the simultaneous acquisition of low- and high-energy data and the reconstruction of virtual monochromatic images ranging from 40 to 200 keV, retrospectively. Low-energy virtual monochromatic images can enhance the contrast of images, thereby facilitating reduced contrast media. In case 1, abdominal computed tomography angiography at 50 keV using 40% of the conventional dose of contrast media revealed the artery that was the source of diverticular bleeding in the ascending colon. In case 2, ischemia of the transverse colon was diagnosed by contrast-enhanced computed tomography and iodine-selective imaging using 40% of the conventional dose of contrast media. In case 3, advanced esophagogastric junctional cancer was staged and preoperative abdominal computed tomography angiography could be obtained with 30% of the conventional dose of contrast media. However, the texture of virtual monochromatic images may be a limitation at low energy. Keywords: Virtual monochromatic images, Contrast-induced nephropathy

  13. Assessment of DNA double-strand breaks induced by intravascular iodinated contrast media following in vitro irradiation and in vivo, during paediatric cardiac catheterization.

    Science.gov (United States)

    Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M

    2016-01-01

    Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. Copyright © 2015 John Wiley & Sons, Ltd.

  14. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd; Schwenke, Carsten; Huppertz, Alexander

    2014-01-01

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m 2 ) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G 30 , 30 mL; G 40 , 40 mL; G 50 , 50 mL; G 60 , 60 mL; G 70 , 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G 30 to 478.2 and 571.8 HU in G 70 . Mean attenuation values were higher in groups with higher CM volumes (P 30 , G 40 , G 50 , G 60 and G 70 were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  15. The effects of X-ray energy and an iodine-based contrast agent on chromosome aberrations

    International Nuclear Information System (INIS)

    Matsubara, Sho; Kubota, Nobuo; Katoh, Tsuguhisa; Yoshino, Norio; Sasaki, Takehito; Sasaki, Masao S.

    1994-01-01

    A study was undertaken to evaluate the effect of combining irradiation with X rays of various energies and an iodine-based contrast agent on the induction of chromosome aberrations in the peripheral lymphocytes of blood samples taken from healthy young donors. Although no enhancement of the effect of radiation was induced when blood samples with the iodine-based contrast agent were given 35 kV X irradiation, an 80 kV X-ray exposure induced an enhanced level of chromosome aberrations, and a 250 kV X irradiation, an enhancement of the frequencies of chromosome aberrations was seen in blood samples with the iodine-based contrast agent, especially when a Lucite phantom was employed in studies to increase the scattered rays. It was thus shown by microdosimetric analysis that X irradiation combined with an iodine-based contrast agent causes an enhancement of the absorbed radiation dose, which is dependent on the X-ray energies employed. This phenomenon may have clinical use in the radiotherapeutic management of tumors, although further extensive studies of tumor vascularity must be pursued before this can be applied clinically. 21 refs., 8 figs., 3 tabs

  16. Contrast induced-acute kidney injury following peripheral angiography with carbon dioxide versus iodinated contrast media: A meta-analysis and systematic review of current literature.

    Science.gov (United States)

    Ghumman, Saad S; Weinerman, Jonathan; Khan, Aazib; Cheema, Mubeen S; Garcia, Marlene; Levin, Daniel; Suri, Rajeev; Prasad, Anand

    2017-09-01

    We conducted a meta-analysis to compare the incidence of acute kidney injury (AKI) with carbon dioxide (CO 2 ) versus iodinated contrast media (ICM). Contrast induced-acute kidney injury (CI-AKI) is a known complication following endovascular procedures with ICM. CO 2 has been employed as an alternative imaging medium as it is nontoxic to the kidneys. Search of indexed databases was performed and 1,732 references were retrieved. Eight studies (7 observational, 1 Randomized Controlled Trial) formed the meta-analysis. Primary outcome was AKI. Fixed effect model was used when possible in addition to analysis of publication bias. In this meta-analysis, 677 patients underwent 754 peripheral angiographic procedures. Compared with ICM, CO 2 was associated with a decreased incidence of AKI (4.3% vs. 11.1%; OR 0.465, 95% CI: 0.218-0.992; P = 0.048). Subgroup analysis of four studies that included granular data for patients with chronic kidney disease (CKD) did not demonstrate a decreased incidence of AKI with CO 2 (4.1% vs. 10.0%; OR 0.449, 95% CI: 0.165-1.221, P = 0.117). Patients undergoing CO 2 angiography experienced a higher number of nonrenal events including limb/abdominal pain (11 vs. 0; P = 0.001) and nausea/vomiting (9 vs. 1; P = 0.006). In comparison to ICM, CO 2 use is associated with a modestly reduced rate of AKI with more frequent adverse nonrenal events. In studies that use CO 2 as the primary imaging agent, the average incidence of AKI remained high at 6.2%-supporting the concept that factors other than renal toxicity from ICM may contribute to renal impairment following peripheral angiography. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  17. Clinical experience with a non-ionic contrast medium (ultravist) in left ventriculography

    International Nuclear Information System (INIS)

    Lee, Ghi Jai; Park, Jae Hyung; Soe, Gwy Suk; Hong, Ju Hee; Han, Man Chung

    1988-01-01

    Non-ionic contrast medium, iopromide (Ultravist), was compared with ionic contrast medium, ioxitalamate (Telebrix), for efficacy and safety in 63 patients undergoing left ventriculography. In all patients, adverse symptoms and signs including pain, heat sense, nausea, vomiting, etc., were checked during and shortly after the injection. Blood pressure, heart rate, EKG and left ventricular pressure were also monitored during the study, and CBC, UA, BUN and creatinine were checked before and 24 hours after the study. The cineangiographic films were analysed and compared by 2 radiologists for the quality. Serious adverse effect did not occur in any case. Minor effects, especially nausea, were lee frequently caused by non-ionic contrast medium than by ionic contrast medium, and heat sense to non-ionic contrast medium was less severe than to ionic contrast medium. Except slightly elevated LVEDP at 1,5 minutes after the study in patients given ionic contrast medium, there was no significant change of electrophysiologic parameters and laboratory findings in both groups. In regard to image quality, there was no significant difference between ionic and non-ionic contrast medium. Thus non-ionic contrast medium, iopromide, appears to be safer for use in left ventriculography than the conventional ionic contrast medium, particularly in those patients at high risk of adverse effects.

  18. Patient safety and adverse events in contrast medium examinations

    International Nuclear Information System (INIS)

    Enge, I.; Edgren, J.

    1989-01-01

    This volume contains six contributions dealing with the properties, safety and economic aspects (lower risks but higher costs of new low-osmonality contrast media compared to the older high-osmonality, ionic ones) of contrast media used in radiology, and risks involved in procedures for administering of radiologic contrast media. (H.W.). refs.; figs.; tabs

  19. Stability of iodinated contrast media in UV-laser irradiation and toxicity of photoproducts

    International Nuclear Information System (INIS)

    Groenewaeller, E.F.; Kehlbach, R.; Claussen, C.D.; Duda, S.H.; Wahl, H.G.; Rodemann, H.P.

    1998-01-01

    Purpose: In XeCl-Excimer laser angioplasty, unintended and possibly harmful interaction of the UV-laser light and the contrast media may occur due to the high concentration of contrast medium proximal to the occlusion or subtotal stenosis. Methods: One ml of three nonionic monomeric contrast agents (iopromide, iomeprol, iopamidol), one nonionic dimetric (jotrolane), and one ionic monomeric (amidotrizoate) X-ray contrast agent were irradiated with a XeCl excimer laser (λ=308 nm, pulse duration 120 ns, 50 Hz) using a 9 French multifiber catheter (12 sectors). Up to 20 000 pulses (106 J) were applied. Using high performance liquid chromatography the amount of liberated iodide as well as the fraction of unchanged contrast media were measured. Cytotoxicity of the photoproducts was tested in a colony formation assay of human skin fibroblasts. The contrast agents were irradiated with 2000 pulses/ml (5.3 mJ/pulse; 10.6 J) and then added to the cell cultures for a period of three hours in a concentration of 10%. Results: Excimer laser irradiation induced iodide liberation of up to 3.3 mg iodide/ml. Up to 19% of the contrast agents changed their original molecular structure. Incubation of irradiated contrast agents resulted in a significantly decreased potential for colony formation (p values ranging from 0.0044 to 0.0102) with significantly higher toxicity of amidotrizoate and iomeprol in comparison to iopromide, iotrolan, and iopamidol. Discussion: Due to the cytotoxic photoproducts and the high level of liberated iodide, it is recommended to flush the artery with physiological saline solution before applying a pulsed excimer laser in human arterial obstructions in order to reduce the contrast agent concentration at the site of irradiation. (orig.) [de

  20. The haemodynamic effects of iodinated water soluble radiographic contrast media: a review

    International Nuclear Information System (INIS)

    Morcos, S.K.; Dawson, P.; Pearson, J.D.; Jeremy, J.Y.; Davenport, A.P.; Yates, M.S.; Tirone, P.; Cipolla, P.; Haeen, C. de; Muschick, P.; Krause, W.; Refsum, H.; Emery, C.J.; Liss, Per; Nygren, A.; Haylor, J.; Pugh, N.D.; Karlsson, J.O.G.

    1998-01-01

    All classes of iodinated water-soluble radiographic contrast media (RCM) are vasoactive with the iso-osmolar dimers inducing the least changes in the vascular tone. The mechanisms responsible for RCM-induced changes in the vascular tone are not fully understood and could be multifactorial. A direct effect on the vascular smooth muscle cells causing alterations in the ion exchanges across the cell membrane is thought to be an important factor in RCM-induced vasodilatation. The release of the endogenous vasoactive mediators adenosine and endothelin may also play a crucial role in the haemodynamic effects of RCM particularly in the kidney. In addition, the effects of RCM on blood rheology can cause a reduction in the blood flow in the microcirculation. The purpose of this review is to discuss the pathophysiology of the haemodynamic effects of RCM and to offer some insight into the biology of the endothelium and vascular smooth muscle cells as well as the pharmacology of the important vasoactive mediators endothelin and adenosine

  1. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  2. Speckle contrast diffuse correlation tomography of complex turbid medium flow

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chong; Irwin, Daniel; Lin, Yu; Shang, Yu; He, Lian; Kong, Weikai; Yu, Guoqiang [Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky 40506 (United States); Luo, Jia [Department of Pharmacology and Nutritional Sciences, University of Kentucky, Lexington, Kentucky 40506 (United States)

    2015-07-15

    Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupled to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary

  3. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Schwenke, Carsten [SCO:SSiS - Schwenke Consulting, Berlin (Germany); Huppertz, Alexander [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); ISI - Imaging Science Institute Charite, Berlin (Germany)

    2014-01-15

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m{sup 2}) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G{sub 30}, 30 mL; G{sub 40}, 40 mL; G{sub 50}, 50 mL; G{sub 60}, 60 mL; G{sub 70}, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G{sub 30} to 478.2 and 571.8 HU in G{sub 70}. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in G{sub 30}, G{sub 40}, G{sub 50}, G{sub 60} and G{sub 70} were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  4. Valuation of using saline flush technique of contrast medium on abdominal multidetector row CT scanning

    International Nuclear Information System (INIS)

    Zhao Hong; Wang Ying; He Yanli; Liu Xiaobing; Bao Shiliang; Han Mingjun

    2006-01-01

    Objective: The purpose of this study was to compare the enhancement degree of abdomen organs and vessels after different amount of contrast medium using saline flush in abdomen MDCT scanning, which aimed to not affect contrast enhancement, decreased the amount of contrast medium, and reduced the side-effect. Methods: This study group consisted of 75 patients who were referred for contrast enhanced abdominal MDCT for various reasons. Patients were allocated into three groups: injection of 100ml of contrast medium only (A group), injection of 80ml pushed with 20ml of saline solution (B group), and injection of 70ml pushed with 30ml of saline solution (C group). Attenuation values were measured from the liver, spleen, pancreas, kidney, aorta, portal vein, and inferior vena cava in 33 second and 80 second of imaging after injection contrast medium. Results: The portal venous phases of the spleen, pancreas, kidney, aorta, portal vein had statistically significant difference among groups A, B and C. Post hoc test showed statistically significant difference between A group and C group, But no statistically significant difference during the portal venous phases of the pancreas and the kidney between A group and B group. Conclusion: Using a saline flush technique after the injection contrast medium in abdominal MDCT reduced waste of contrast medium and decrease in nephrotoxicity, at the same time, it would not lose important diagnostic information and saved patients cost for the contrast medium. (authors)

  5. Iodinated contrast media induce neutrophil apoptosis through a mitochondrial and caspase mediated pathway.

    LENUS (Irish Health Repository)

    Fanning, N F

    2012-02-03

    Iodinated contrast media (ICM) can induce apoptosis (programmed cell death) in renal, myocardial and endothelial cells. Following intravascular injection, circulating immune cells are exposed to high concentrations of ICM. As neutrophils constitutively undergo apoptosis we hypothesized that ICM may adversely affect neutrophil survival. Our aim was to investigate the effect of ICM on neutrophil apoptosis. Neutrophils were isolated from healthy subjects and cultured in vitro with ionic (diatrizoate and ioxaglate) and non-ionic (iohexol and iotrolan) ICM. The effect of ICM on neutrophil apoptosis in both unstimulated and lipopolysaccharide-stimulated neutrophils was determined by annexin V flow cytometry. The influence of physicochemical properties of the different ICM on apoptosis of neutrophils was also studied. We further investigated the effects of ICM on key intracellular signal pathways, including p38 mitogen-activated protein kinase (MAPK) by Western blotting, and mitochondrial depolarization and caspase activity by flow cytometry. Isoiodine concentrations (20 mg ml(-1)) of ionic (diatrizoate 69.6+\\/-2.9%; ioxaglate 58.9+\\/-2.0%) and non-ionic (iohexol 57.3+\\/-2.9%; iotrolan 57.1+\\/-2.6%) ICM significantly induced neutrophil apoptosis over control levels (47.7+\\/-1.4%). The apoptotic effect of ICM was influenced by their chemical structure, with ionic ICM having a more significant (p<0.01) apoptotic effect than non-ionic ICM (p<0.05). Furthermore, ICM reversed the anti-apoptotic effect of lipopolysaccharide (1000 ng ml(-1)) treated neutrophils to control levels (23.0+\\/-3.5% to 61.2+\\/-5.3%; n=4; p<0.05). These agents induce apoptosis through a p38 MAPK independent pathway that results in mitochondrial depolarization, and is dependent on caspase activation. As neutrophils play a central role in host response to infection and injury, ICM, through induction of neutrophil apoptosis, could have a significant deleterious effect on host immune defence and

  6. Comparison of renal toxicity after injection of CT contrast medium and MR contrast medium: change of renal function in acute renal failure rat models

    International Nuclear Information System (INIS)

    Han, Young min; Lee, Young Hwan; Kim, Sang Won; Jin, Kong Young; Kim, Won; Chung, Gyung Ho

    2002-01-01

    To determine renal toxicity through changes in renal function after the injection of CT and MRI contrast media into rats in which acute renal failure (ARF) was induced. To cause acute renal failure, the abdominal cavity of 110 male rats each weighing 250-300 gm was opened via a midline incision under anesthesia. Microvascular clamps were placed on both renal arteries and veins to completely block renal blood flow for 45 minutes, and were then removed, allowing blood flow to return to the kidneys. ARF, defined as a two-fold difference in the creatinine level before ARF and 48 hours after, was successfully induced in 60 of the rats. These were divided into two groups: one was injected with CT contrast medium and the other with MRI contrast medium. Each CT and MRI group was divided into a low dose (0.5 cc/kg, 0.2 ml/kg), standard dose (2 cc/kg, 0.8 ml/kg), and high dose (8 cc/kg, 3.2 ml/kg) sub-group; thus, there was a total of six groups with ten rats in each. Blood samples were obtained before ARF, 48 hours after, and 48 hours after contrast injection, and CT scanning and MRI were performed after blood sampling at 48 hours. In each group, creatinine levels 48 hours after contrast injection were compared by means of the ANOVA test. There were no significant differences in creatinine levels between the CT and MRI contrast medium groups (p=0.116), nor between the animals to which different doses of CT and MRI contrast medium, were administered. After both standard and high doses, CT and MRI provided good images. In rats in which acute renal failure was induced, renal function did not change according to whether CT or MRI contrast medium was injected. Thus, the two media induce similar levels of toxicity

  7. Synthesis of PEG-Iodine-Capped Gold Nanoparticles and Their Contrast Enhancement in In Vitro and In Vivo for X-Ray/CT

    International Nuclear Information System (INIS)

    Sun-Hee, K.; Eun-Mi, K.; Chang-Moon, L.; Dong, W.K.; Seok, T.L.; Myung-Hee, S.; Hwan-Jeong, J.

    2012-01-01

    We designed gold nanoparticles (AuNPs) capped with iodine and polyethylene glycol (PEG) to provide effective enhancement for X-ray CT imaging. The methoxy PEG-iodine-capped AuNPs were prepared through the chemisorption of iodine and substitution of methoxy PEG-SH onto the surface of gold nanoparticles, and severe aggregation in TEM was not observed. The binding energies of Au 4f 7/2 and I 3d 5/2 of the methoxy PEG-iodine-capped AuNPs were obtained as 84.1 eV and 619.3 eV, respectively. The binding energy shift of methoxy PEG-iodine-capped AuNPs would be resulted from the chemisorption between gold nanoparticles and iodine atoms. The methoxy PEG-iodine-capped AuNPs have higher enhancement compared to PEG-capped gold nanoparticles in the same amount of gold in vitro. After postinjection of methoxy PEG-iodine-capped AuNPs into the mice, dramatic contrast enhancement at the heart, aorta, liver, and kidney was observed, this was maintained up to 5 days, and there was no evidence of apparent toxicity. In conclusion, methoxy PEG-iodine-capped AuNPs might be a good candidate as a CT contrast agent for blood pool imaging, and this will also contribute to the prolongation of a blood circulation time for X-ray CT imaging.

  8. Kinetics of an oxygen – iodine active medium with iodine atoms optically pumped on the {sup 2}P{sub 1/2} – {sup 2}P{sub 3/2} transition

    Energy Technology Data Exchange (ETDEWEB)

    Zagidullin, M V; Azyazov, V N [Samara Branch of the P.N. Lebedev Physical Institute, Russian Academy of Sciences, Samara (Russian Federation); Malyshev, M S [S.P. Korolev Samara State Aerospace University, Samara (Russian Federation)

    2015-08-31

    The kinetics of the processes occurring in an O{sub 2} – I{sub 2} – He – H{sub 2}O gas flow in which photodissociation of molecular iodine at a wavelength close to 500 nm and excitation of atomic iodine on the {sup 2}P{sub 1/2} – {sup 2}P{sub 3/2} transition by narrow-band radiation near 1315 nm are implemented successively has been analysed. It is shown that implementation of these processes allows one to form an oxygen – iodine medium with a high degree of dissociation of molecular iodine and a relative content of singlet oxygen O{sub 2}(a{sup 1}Δ) exceeding 10%. Having formed a supersonic gas flow with a temperature ∼100 K from this medium, one can reach a small-signal gain of about 10{sup -2} cm{sup -1} on the {sup 2}P{sub 1/2} – {sup 2}P{sub 3/2} transition in iodine atoms. The specific power per unit flow cross section in the oxygen – iodine laser with this active medium may reach ∼100 W cm{sup -2}. (active media)

  9. Magnetic resonance tomography of the orbit: First experiences with the paramagnetic contrast medium gadolinium-DTPA

    International Nuclear Information System (INIS)

    Markl, A.; Vogl, T.; Scheidhauer, K.; Riedel, K.G.; Oeckler, R.

    1986-01-01

    In 21 patients with orbital mass lesions MRI was performed before and after administration of paramagnetic contrast medium, gadolinium-DPTA. In comparison to the plain scan the differentiation of the tumorous tissue against the surrounding structures was improved after application of contrast medium despite a partially moderate increase in signal intensity. Especially highly vascular tumors and vessel diseases show a significant contrast enhancement. With increasing experience in larger number of patients a tissue differentiation seems to be possible. (orig.) [de

  10. Comparison of soft tissue effects of conventional ionic, low osmolar ionic and nonionic iodine containing contrast material in experimental animals

    International Nuclear Information System (INIS)

    McAlister, W.H.; Kissane, J.M.

    1990-01-01

    Conventional, low osmolar, and non-ionic iodine containing contrast media and saline controls were placed in the paws, muscles, and subcutaneous tissues of Sprague-Dawley rat thighs. The paw injections were observed and photographed, while the thighs were examined histologically. Results showed that although the low osmolar and non-ionic agents did produce inflammatory reactions and focal necrosis in the soft tissues, they were much better tolerated than were the conventional ionic agents. A non-ionic or low osmolar ionic contrast agent should be strongly considered when a possibility for extravasation exists. (orig.)

  11. Computed Tomography Imaging of Solid Tumors Using a Liposomal-Iodine Contrast Agent in Companion Dogs with Naturally Occurring Cancer.

    Science.gov (United States)

    Ghaghada, Ketan B; Sato, Amy F; Starosolski, Zbigniew A; Berg, John; Vail, David M

    2016-01-01

    Companion dogs with naturally occurring cancer serve as an important large animal model in translational research because they share strong similarities with human cancers. In this study, we investigated a long circulating liposomal-iodine contrast agent (Liposomal-I) for computed tomography (CT) imaging of solid tumors in companion dogs with naturally occurring cancer. The institutional animal ethics committees approved the study and written informed consent was obtained from all owners. Thirteen dogs (mean age 10.1 years) with a variety of masses including primary and metastatic liver tumors, sarcomas, mammary carcinoma and lung tumors, were enrolled in the study. CT imaging was performed pre-contrast and at 15 minutes and 24 hours after intravenous administration of Liposomal-I (275 mg/kg iodine dose). Conventional contrast-enhanced CT imaging was performed in a subset of dogs, 90 minutes prior to administration of Liposomal-I. Histologic or cytologic diagnosis was obtained for each dog prior to admission into the study. Liposomal-I resulted in significant (p contrast agent was demonstrated. Liposomal-I enabled visualization of primary and metastatic liver tumors. Sub-cm sized liver lesions grossly appeared as hypo-enhanced compared to the surrounding normal parenchyma with improved lesion conspicuity in the post-24 hour scan. Large liver tumors (> 1 cm) demonstrated a heterogeneous pattern of intra-tumoral signal with visibly higher signal enhancement at the post-24 hour time point. Extra-hepatic, extra-splenic tumors, including histiocytic sarcoma, anaplastic sarcoma, mammary carcinoma and lung tumors, were visualized with a heterogeneous enhancement pattern in the post-24 hour scan. The long circulating liposomal-iodine contrast agent enabled prolonged visualization of small and large tumors in companion dogs with naturally occurring cancer. The study warrants future work to assess the sensitivity and specificity of the Liposomal-I agent in various types of

  12. Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study

    Directory of Open Access Journals (Sweden)

    Guiffant G

    2013-09-01

    Full Text Available Gérard Guiffant,1 Jean Jacques Durussel,1 Patrice Flaud,1 Laurent Royon,1 Pierre Yves Marcy,2 Jacques Merckx1,31University Paris Diderot, Paris, France; 2Radiodiagnosis and Interventional Radiology Department, Caen, France; 3University Teaching Hospital Necker-Enfants Malades, Paris, FrancePurpose: The use of totally implantable venous access devices (TIVADs certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter?Results: The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on.Conclusion: We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice

  13. Local blood-brain barrier penetration following systemic contrast medium administration

    International Nuclear Information System (INIS)

    Utz, R.; Ekholm, S.E.; Isaac, L.; Sands, M.; Fonte, D.

    1988-01-01

    The present study was initiated by a severe complication in a patient with renal dysfunction who developed cortical blindness and weakness of her left extremities 30 hours following renal and abdominal angiography. To evaluate the impact of prolonged high serum concentrations of contrast medium (CM) this clinical situation was simulated in a laboratory model using sheep with elevated serum levels of contrast medium maintained for 48 hours. The experimental data did not support the theory that the prolonged exposure to high circulating levels of contrast medium (4 ml/kg body weight of meglumine diatrizoate 60%) is sufficient alone to cause penetration of the blood-brain barrier. (orig.)

  14. Re-exposure to low osmolar iodinated contrast media in patients with prior moderate-to-severe hypersensitivity reactions: A multicentre retrospective cohort study.

    Science.gov (United States)

    Park, Hye Jung; Park, Jung-Won; Yang, Min-Suk; Kim, Mi-Yeong; Kim, Sae-Hoon; Jang, Gwang Cheon; Nam, Young-Hee; Kim, Gun-Woo; Kim, Sujeong; Park, Hye-Kyung; Jung, Jae-Woo; Park, Jong-Sook; Kang, Hye-Ryun

    2017-07-01

    To evaluate the outcomes of re-exposure to low-osmolar iodinated contrast medium (LOCM) in patients with a history of moderate-to-severe hypersensitivity reaction (HSR). We retrospectively evaluated a cohort comprising all subjects satisfying the following conditions at 11 centres: (1) experienced a moderate-to-severe HSR to LOCM by December 2014, and (2) underwent contrast-enhanced computed tomography after the initial HSR between January 2014 and December 2014. A total of 150 patients with 328 instances of re-exposure were included; the recurrence rate of HSR was 19.5%. Patients with severe initial HSR exhibited a higher recurrence rate of severe HSR compared to patients with moderate initial HSR, despite more intensive premedication. In the multivariate analysis, the independent risk factors for recurrence of HSR were diabetes, chronic urticaria, drug allergy other than to iodinated contrast media (ICM) and severe initial HSR. The risk of recurrent HSR was 67.1% lower in cases where the implicated ICM was changed to another one (odds ratio: 0.329; P = 0.001). However, steroid premedication did not show protective effects against recurrent HSR. In high-risk patients who have previously experienced a moderate-to-severe initial HSR to LOCM, we should consider changing the implicated ICM to reduce recurrence risk. • In patients with moderate-to-severe HSR, steroid premedication only shows limited effectiveness. • Changing the implicated ICM can reduce the recurrence of HSR to ICM. • Diabetes, chronic urticaria and drug allergies increase the risk of ICM HSR.

  15. Arterial double-contrast dual-energy MDCT: in-vivo rabbit atherosclerosis with iodinated nanoparticles and gadolinium agents

    Science.gov (United States)

    Carmi, Raz; Kafri, Galit; Altman, Ami; Goshen, Liran; Planer, David; Sosna, Jacob

    2010-03-01

    An in-vivo feasibility study of potentially improved atherosclerosis CT imaging is presented. By administration of two different contrast agents to rabbits with induced atherosclerotic plaques we aim at identifying both soft plaque and vessel lumen simultaneously. Initial injection of iodinated nanoparticle (INP) contrast agent (N1177 - Nanoscan Imaging), two to four hours before scan, leads to its later accumulation in macrophage-rich soft plaque, while a second gadolinium contrast agent (Magnevist) injected immediately prior to the scan blends with the aortic blood. The distinction between the two agents in a single scan is achieved with a double-layer dual-energy MDCT (Philips Healthcare) following material separation analysis using the reconstructed images of the different x-ray spectra. A single contrast agent injection scan, where only INP was injected two hours prior to the scan, was compared to a double-contrast scan taken four hours after INP injection and immediately after gadolinium injection. On the single contrast agent scan we observed along the aorta walls, localized iodine accumulation which can point on INP uptake by atherosclerotic plaque. In the double-contrast scan the gadolinium contributes a clearer depiction of the vessel lumen in addition to the lasting INP presence. The material separation shows a good correlation to the pathologies inferred from the conventional CT images of the two different scans while performing only a single scan prevents miss-registration problems and reduces radiation dose. These results suggest that a double-contrast dual-energy CT may be used for advanced clinical diagnostic applications.

  16. Dual Energy CT Angiography of Peripheral Arterial Disease: Feasibility of Using Lower Contrast Medium Volume.

    Directory of Open Access Journals (Sweden)

    Abdulrahman Almutairi

    Full Text Available One of the main drawbacks associated with Dual Energy Computed Tomography Angiography (DECTA is the risk of developing contrast medium-induced nephropathy (CIN. The aim of the present study was firstly, to design an optimal CT imaging protocol by determining the feasibility of using a reduced contrast medium volume in peripheral arterial DECTA, and secondly, to compare the results with those obtained from using routine contrast medium volume.Thirty four patients underwent DECTA for the diagnosis of peripheral arterial disease. They were randomly divided into two groups: Group 1 (routine contrast volume group with n = 17, injection rate 4-5 ml/s, and 1.5 ml/kg of contrast medium, and Group 2 ((low contrast volume group, with n = 17, injection rate 4-5ml/s, and contrast medium volume 0.75 ml/kg. A fast kilovoltage-switching 64-slice CT scanner in the dual-energy mode was employed for the study. A total of 6 datasets of monochromatic images at 50, 55, 60, 65, 70 and 75 keV levels were reconstructed with adaptive statistical iterative reconstruction (ASIR at 50%. A 4-point scale was the tool for qualitative analysis of results. The two groups were compared and assessed quantitatively for image quality on the basis of signal-to-noise ratio (SNR and contrast-to-noise-ratio (CNR. Radiation and contrast medium doses were also compared.The overall mean CT attenuation and mean noise for all lower extremity body parts was significantly lower for the low volume contrast group (p<0.001, and varied significantly between groups (p = 0.001, body parts (p<0.001 and keVs (p<0.001. The interaction between group body parts was significant with CT attenuation and CNR (p = 0.002 and 0.003 respectively, and marginally significant with SNR (p = 0.047, with minimal changes noticed between the two groups. Group 2 (low contrast volume group displayed the lowest image noise between 65 and 70 keV, recorded the highest SNR and CNR at 65 keV, and produced significantly lower

  17. Dry preparation for virtual CT colonography with fecal tagging using water-soluble contrast medium: initial results

    International Nuclear Information System (INIS)

    Bielen, Didier; Thomeer, Maarten; Vanbeckevoort, Dirk; Marchal, Guy; Kiss, Gabriel; Maes, Frederik; Rutgeerts, Paul

    2003-01-01

    The purpose of this study was to evaluate the feasibility of a dry bowel preparation, i.e. without laxative fluids, for virtual CT colonography (VCTC), and its impact on patient acceptance compared with conventional colonoscopy (CC). A randomly chosen patient population scheduled for CC (n=11) was first submitted to VCTC after a dry preparation, consisting of low-residue meals combined with a small amount of a iodinated water-soluble contrast medium during each meal 3 days before VCTC. In different colon segments and between different persons, the degree of tagging in VCTC was evaluated and graded. Patient acceptance and future preference were assessed for both preparations as well as for both investigations. The mixing of the contrast with the intestinal content results in contrast impregnated stool, the tagged feces. The degree of fecal tagging was good in the majority of the patients and the colonic segments, especially in the descending colon and sigmoid. Furthermore, patient acceptance and preference were clearly in favour of VCTC compared with CC merely because of the non-invasiveness of the dry preparation. Dry bowel preparation and VCTC is a promising approach towards a patient-friendly colon cancer-screening setup. (orig.)

  18. Paediatric cardiac catheterization. Controlled, randomized study of two iodinated contrast media: iopromide 300 and ioxaglate 320 mgI/ml

    International Nuclear Information System (INIS)

    Amiel, M.; Revel, D.

    1989-01-01

    Thirty-one children were included in a prospective randomized trial comparing a new non-ionic contrast medium, iopromide 300 and the ionic low osmolar contrast medium, ioxaglate 320 mgI/ml in pediatric cardiac catheterization. There were fewer adverse effects with iopromide but no statistically significant difference was demonstrated in this small population, with a very low incidence of allergoid reactions; this tendency was confirmed by meta-analysis of the multicentre study [fr

  19. Prevalence of latent and manifest hyperthyroidism in an iodine-deficient area: non-selected patient population admitted for CT studies with iodine-containing contrast agents

    International Nuclear Information System (INIS)

    Saam, T.; Hess, T.; Kasperk, C.; Kauffmann, G.W.; Duex, M.

    2005-01-01

    Purpose: to evaluate the prevalence of latent and manifest hyperthyroidism in a non-selected group of patients admitted for contrast enhanced CT studies blood samples were tested for the levels of thyroid-stimulating hormone (TSH). Material and methods: TSH blood levels were obtained in 548 consecutive patients who were scheduled for contrast-enhanced (Iopromide; 300 mg iodine/ml) CT scanning. In case of TSH levels registered (sodium perchlorate) was commenced before scanning. In case of TSH levels < 0.1 mU/l, CT scanning was not performed but further evaluation of the thyroid function was initiated. Results: TSH blood levels ranged from 0.4 to 7.5 mU/l in 512 patients, and 36 patients (6.6%) had TSH blood levels < 0.4 mU/l and 9 patients blood levels < 0.1 mU/l, with 32 of those patients (5.8%) having regular T3 and T4 blood levels consistent with latent hyperthyroidism. In 4 patients (0.8%), T3 or T4 blood levels were increased consistent with manifest hyperthyroidism. Conclusion: in South Germany, the prevalence of latent or manifest hyperthyroidism in a non-selected patient group is high. Therefore TSH blood levels should be obtained prior to contrast-enhanced CT studies. (orig.)

  20. Contrast-medium-induced nephropathy: is there a new consensus? A review of published guidelines

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Morcos, Sameh K.

    2006-01-01

    The interest in contrast-medium-induced nephropathy has increased considerably during the last few years. Various guidelines regarding identifying patients at risk and measures to reduce the incidence of this complication have been proposed. The aim of this review was to analyse whether there is some consistency amongst these guidelines. A Medline search for the keyword ''contrast medium induced nephropathy'' during the period from the beginning of 2003 through the end of September 2005 was carried out. Only papers in English were reviewed. Thirteen guidelines were identified. Inconsistency was observed regarding advise on the prophylactic use of drugs and the isoosmolar dimer to reduce the incidence of contrast-medium-induced nephropathy. Consistency was found in relation to the importance of hydration, cessation of intake of nephrotoxic drugs and administration of the lowest possible dose of contrast medium. No new consensus has been observed in comparison to the European Society for Urogenital Radiology (ESUR) guidelines, which were published in 1999. (orig.)

  1. The affects of contrast medium on renal function in selective coronary angiography and intervention

    International Nuclear Information System (INIS)

    Chen Yueguang; Lv Baojing

    2006-01-01

    Selective coronary angiography and intervention with injection of contrast medium into the coronary arteries has become very common in dealing with coronary cardiac diseases. The excretion of contrast medium through kidneys may lead to acute renal functional insufficiency, especially for those suffering from chronic nephropathy, diabetes and cardiac functional disorder to form the so called 'contrast medium nephropathy' which is considered as the number second drug induced acute renal functional failure. Although routine preventive measure including low osmotic contrast medium and fine hydrotherapy have been taken, 14% incidences still occur with renal functional damage. The majority could be reversible but the minority needs emergent hemodialysis or even with persistent renal functional damage in a few ones. (authors)

  2. Computed tomography using contrast medium in disorders of the patello-femoral joint

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kenji; Chiba, Mitsuho; Morita, Hiromi; Kikuchi, Toshihiko; Shimada, Yoichi; Yamamoto, Masahiro; Tozawa, Kazuma

    1985-01-01

    The morphology and alignment of the articular cartilage of the patello-femoral joint were examined by computed tomography (CT) using a contrast medium in 15 patients with a chief complaint of patellar pain. CT was undertaken immediately after injecting a contrast medium and air into the knee joint. Retention and irregularity of the contrast medium in the joint estimated the expansion and depth of lesions in patients with osteomalacia of the auricular joint or osteoarthritis of the knee, and the thickness of the auricular cartilage. Considering the individual differences of the patella itself and specificity of the form of the auricular cartilage, the auricular joint should also be examined in terms of alignment of the cartilage surface. CT using a contrast medium is a simple, less invasive method for evaluating disorders of the patello-femoral joint.

  3. Intraarterial CT Angiography Using Ultra Low Volume of Iodine Contrast – Own Experiences

    International Nuclear Information System (INIS)

    Garcarek, Jerzy; Kurcz, Jacek; Guziński, Maciej; Banasik, Mirosław; Miś, Marcin; Gołębiowski, Tomasz

    2015-01-01

    High volume of intravenous contrast in CT-angiography may result in contrast-induced nephropathy. Intraarterial ultra-low volume of contrast medium results in its satisfactory blood concentration with potentially good image quality. The first main purpose was to assess the influence of the method on function of transplanted kidney in patients with impaired graft function. The second main purpose of the study was to evaluate the usefulness of this method for detection of gastrointestinal and head-and-neck haemorrhages. Between 2010 and 2013 intraarterial CT-angiography was performed in 56 patients, including 28 with chronic kidney disease (CKD). There were three main subgroups: 18 patients after kidney transplantation, 10 patients with gastrointestinal hemorrhage, 8 patients with head-and-neck hemorrhage. Contralateral or ipsilateral inguinal arterial approach was performed. The 4-French vascular sheaths and 4F-catheters were introduced under fluoroscopy. Intraarterial CT was performed using 64-slice scanner. The scanning protocol was as follows: slice thickness 0.625 mm, pitch 1.3, gantry rotation 0.6 sec., scanning delay 1–2 sec. The extent of the study was established on the basis of scout image. In patients with CKD 6–8 mL of Iodixanol (320 mg/mL) diluted with saline to 18–24 mL was administered at a speed of 4–5 mL/s. Vasculature was properly visualized in all patients. In patients with impaired renal function creatinine/eGFR levels remained stable in all but one case. Traditional arteriography failed and CT-angiography demonstrated the site of bleeding in 3 of 10 patients with symptoms of gastrointestinal bleeding (30%). In 8 patients with head-and-neck bleeding CT-angiography did not prove beneficial when compared to traditional arteriography. 1. Ultra-low contrast intraarterial CT-angiography does not deteriorate the function of transplanted kidneys in patients with impaired graft function. 2. 3D reconstructions allow for excellent visualization of

  4. Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study.

    Science.gov (United States)

    Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Royon, Laurent; Marcy, Pierre Yves; Merckx, Jacques

    2013-01-01

    The use of totally implantable venous access devices (TIVADs) certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter? The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on. We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice.

  5. Adverse effects in coronary angiography: a comparative study of different temperature contrast medium

    International Nuclear Information System (INIS)

    Zhou Peng; Wang Qiulin; Cai Guocai; Li Lu; Jiang Licheng; Yang Zhen; Huang Xiuping

    2011-01-01

    Objective: To investigate the correlation between different temperature contrast medium and the occurrence of adverse effects, including the chest discomfort, the changes of heart rate, ST segment and T wave, the operating time and the used dosage of contrast medium, in performing coronary angiography. Methods: According to the contrast medium temperature used in coronary angiography, the patients were randomly divided into two groups: room temperature group (n=521) and warm temperature group (n=522). The contrast medium used in warm temperature group was bathed in 37 ℃ water for 60 minutes when the coronary angiography was carried out. The T Wave amplitude changes ≥ 0.01 mv, ST segment depression ≥ 0.05 mv, changes in heart rate ≥ 10 times/min were brought into the positive accounting. The occurrence of adverse effects, such as palpitation, chest distress and pectoralgia, the operative time and the used dosage of contrast medium were recorded. The results were analyzed and compared between the two groups. Results: Statistically significant differences in the changes of heart rate, ST segment deviation, T wave change and operating time existed between the two groups (P<0.05). And the difference in the occurrence of adverse effects between the two groups was also statistically significant (P<0.05). Conclusion: When performing coronary angiography, warming of the contrast medium with water bath is greatly conducive to the prevention of cardiac adverse effects. (authors)

  6. Changes in risk of immediate adverse reactions to iodinated contrast media by repeated administrations in patients with hepatocellular carcinoma.

    Directory of Open Access Journals (Sweden)

    Naoto Fujiwara

    Full Text Available BACKGROUND: To elucidate whether repeated exposures to iodinated contrast media increase the risk of adverse reaction. MATERIALS AND METHODS: We retrospectively reviewed 1,861 patients with hepatocellular carcinoma who visited authors' institution, a tertiary referral center, between 2004 and 2008. We analyzed cumulative probability of adverse reactions and risk factors. We categorized all symptoms into hypersensitivity reactions, physiologic reactions, and other reactions, according to the American College of Radiology guidelines, and evaluated each category as an event. We estimated the association between hazard for adverse reactions and the number of cumulative exposures to contrast media. We also evaluated subsequent contrast media injections and adverse reactions. RESULTS: There were 23,684 contrast media injections in 1,729 patients. One hundred and thirty-two patients were excluded because they were given no contrast media during the study period. Adverse reactions occurred in 196 (0.83% patients. The cumulative incidence at 10(th, 20(th, and 30(th examination was 7.9%, 15.2%, and 24.1%, respectively. Presence of renal impairment was found to be one of risk factors for adverse reactions. The estimated hazard of overall adverse reaction gradually decreased until around 10(th exposure and rose with subsequent exposures. The estimated hazard of hypersensitivity showed V-shaped change with cumulative number of exposures. The estimated hazard of physiologic reaction had a tendency toward decreasing and that of other reaction had a tendency toward increasing. Second adverse reaction was more severe than the initial in only one among 130 patients receiving subsequent injections. CONCLUSION: Repeated exposures to iodinated contrast media increase the risk of adverse reaction.

  7. Changes in risk of immediate adverse reactions to iodinated contrast media by repeated administrations in patients with hepatocellular carcinoma.

    Science.gov (United States)

    Fujiwara, Naoto; Tateishi, Ryosuke; Akahane, Masaaki; Taguri, Masataka; Minami, Tatsuya; Mikami, Shintaro; Sato, Masaya; Uchino, Koji; Uchino, Kouji; Enooku, Kenichiro; Kondo, Yuji; Asaoka, Yoshinari; Yamashiki, Noriyo; Goto, Tadashi; Shiina, Shuichiro; Yoshida, Haruhiko; Ohtomo, Kuni; Koike, Kazuhiko

    2013-01-01

    To elucidate whether repeated exposures to iodinated contrast media increase the risk of adverse reaction. We retrospectively reviewed 1,861 patients with hepatocellular carcinoma who visited authors' institution, a tertiary referral center, between 2004 and 2008. We analyzed cumulative probability of adverse reactions and risk factors. We categorized all symptoms into hypersensitivity reactions, physiologic reactions, and other reactions, according to the American College of Radiology guidelines, and evaluated each category as an event. We estimated the association between hazard for adverse reactions and the number of cumulative exposures to contrast media. We also evaluated subsequent contrast media injections and adverse reactions. There were 23,684 contrast media injections in 1,729 patients. One hundred and thirty-two patients were excluded because they were given no contrast media during the study period. Adverse reactions occurred in 196 (0.83%) patients. The cumulative incidence at 10(th), 20(th), and 30(th) examination was 7.9%, 15.2%, and 24.1%, respectively. Presence of renal impairment was found to be one of risk factors for adverse reactions. The estimated hazard of overall adverse reaction gradually decreased until around 10(th) exposure and rose with subsequent exposures. The estimated hazard of hypersensitivity showed V-shaped change with cumulative number of exposures. The estimated hazard of physiologic reaction had a tendency toward decreasing and that of other reaction had a tendency toward increasing. Second adverse reaction was more severe than the initial in only one among 130 patients receiving subsequent injections. Repeated exposures to iodinated contrast media increase the risk of adverse reaction.

  8. Effects of changes in analytic variables and contrast medium on estimation of glomerular filtration rates by computed tomography in healthy dogs.

    Science.gov (United States)

    Matsuda, Yuri; Kishimoto, Miori; Kushida, Kazuya; Yamada, Kazutaka; Shimizu, Miki; Itoh, Hiroshi

    2017-09-01

    OBJECTIVE To investigate effects of changes in analytic variables and contrast medium osmolality on glomerular filtration rate estimated by CT (CT-GFR) in dogs. ANIMALS 4 healthy anesthetized Beagles. PROCEDURES GFR was estimated by inulin clearance, and dogs underwent CT-GFR with iodinated contrast medium (iohexol or iodixanol) in a crossover-design study. Dynamic renal CT scanning was performed. Patlak plot analysis was used to calculate GFR with the renal cortex or whole kidney selected as the region of interest. The renal cortex was analyzed just prior to time of the second cortical attenuation peak. The whole kidney was analyzed 60, 80, 100, and 120 seconds after the appearance of contrast medium. Automated GFR calculations were performed with preinstalled perfusion software including 2 noise reduction levels (medium and strong). The CT-GFRs were compared with GFR estimated by inulin clearance. RESULTS There was no significant difference in CT-GFR with iohexol versus iodixanol in any analyses. The CT-GFR at the renal cortex, CT-GFR for the whole kidney 60 seconds after appearance of contrast medium, and CT-GFR calculated by perfusion software with medium noise reduction did not differ significantly from GFR estimated by inulin clearance. The CT-GFR was underestimated at ≥ 80 seconds after contrast medium appearance (whole kidney) and when strong noise reduction was used with perfusion CT software. CONCLUSIONS AND CLINICAL RELEVANCE Selection of the renal cortex as region of interest or use of the 60-second time point for whole-kidney evaluation yielded the best CT-GFR results. The perfusion software used produced good results with appropriate noise reduction. IMPACT FOR HUMAN MEDICINE The finding that excessive noise reduction caused underestimation of CT-GFR suggests that this factor should also be considered in CT-GFR examination of human patients.

  9. Aspiration of barium contrast medium in an elderly man with disordered swallowing

    OpenAIRE

    Bağcı Ceyhan, B.; Çelikel, T.; Koç, M.; Ahıskalı, R.; Biren, T.; Ataizi Çelikel, Ç.

    1995-01-01

    The aspiration of contrast medium during the investigation of gastrointestinal diseases is a well recognized hazard, particularly in patients with swallowing disorders. A case is reported in which accidental aspiration of contrast barium occurred owing to disordered swallowing in an elderly man. The infiltration on chest x-ray persisted 2 years after barium contrast aspiration. Inflammatory reaction and retractile, granular material observed in lung biopsy specimens suggested barium-induced p...

  10. Effects of viscosity on power and hand injection of iso-osmolar iodinated contrast media through thin catheters.

    Science.gov (United States)

    Zhang, James J; Hogstrom, Barry; Malinak, Jiri; Ikei, Nobuhiro

    2016-05-01

    It can be challenging to achieve adequate vessel opacification during percutaneous coronary interventions when using thin catheters, hand injection, and iso-osmolar contrast media (CM) such as iodixanol (Visipaque™). To explore these limitations and the possibility to overcome them with iosimenol, a novel CM. Three X-ray contrast media with different concentrations were used in this study. A series of in vitro experiments established the relationship between injection pressure and flow rate in angiography catheters under various conditions. The experiments were conducted with power and hand injections and included a double-blind evaluation of user perception. By using hand injection, it was generally not possible to reach a maximum injection pressure exceeding 50 psi. The time within which volunteers were able to complete the injections, the area under the pressure-time curve (AUC), and assessment of ease of injection all were in favor of iosimenol compared with iodixanol, especially when using the 4F thin catheter. Within the pressure ranges tested, the power injections demonstrated that the amount of iodine delivered at a fixed pressure was strongly related to viscosity but unrelated to iodine concentration. There are substantial limitations to the amount of iodine that can be delivered through thin catheters by hand injection when iso-osmolar CM with high viscosity is used. The only viable solution, besides increasing the injection pressure, is to use a CM with lower viscosity, since the cost of increasing the concentration, in terms of increased viscosity and consequent reduction in flow, is too high. Iosimenol, an iso-osmolar CM with lower viscosity than iodixanol might therefore be a better alternative when thinner catheters are preferred, especially when the radial artery is used as the access site. © The Foundation Acta Radiologica 2015.

  11. Recommendation to use iso-osmotic contrast medium in interventional treatment

    International Nuclear Information System (INIS)

    Zhou Bing; Cheng Yongde

    2012-01-01

    With the rapid development of imaging diagnostic and interventional therapeutic techniques, the contrast medium (CM) has been used more and more common in clinical practice, and meanwhile more and more attention has been paid to the CM-related adverse events. Contrast induced nephropathy (CN) is the most common CM-related adverse event, and CM-related neurotoxicity has already attracted the physicians' attention. The osmotic pressure of the iso-osmotic contrast medium (IOCM) is quite the same as that of the plasma, and therefore its safety is higher than that of low-osmotic contrast medium (LOCM), the patient's tolerance to IOCM is better than that to LOCM. For this reason, the use of IOCM should be strongly recommended in interventional procedures, which is of great significance to the reduction of the occurrence of CM-related adverse events. (authors)

  12. MO-E-17A-02: Incorporation of Contrast Medium Dynamics in Anthropomorphic Phantoms: The Advent of 5D XCAT Models

    Energy Technology Data Exchange (ETDEWEB)

    Sahbaee, P [NC State University, Raleigh, NC (United States); Samei, E [Duke University Medical Center, Durham, NC (United States); Segars, W [Duke University, Durham, NC (United States)

    2014-06-15

    Purpose: To develop a unique method to incorporate the dynamics of contrast-medium propagation into the anthropomorphic phantom, to generate a five-dimensional (5D) patient model for multimodality imaging studies. Methods: A compartmental model of blood circulation network within the body was embodied into an extended cardiac-torso (4D-XCAT) patient model. To do so, a computational physiologic model of the human cardiovascular system was developed which includes a series of compartments representing heart, vessels, and organs. Patient-specific cardiac output and blood volume were used as inputs influenced by the weight, height, age, and gender of the patient's model. For a given injection protocol and given XCAT model, the contrast-medium transmission within the body was described by a series of mass balance differential equations, the solutions to which provided the contrast enhancement-time curves for each organ; thereby defining the tissue materials including the contrastmedium within the XCAT model. A library of time-dependent organ materials was then defined. Each organ in each voxelized 4D-XCAT phantom was assigned to a corresponding time-varying material to create the 5D-XCAT phantom in which the fifth dimension is blood/contrast-medium within the temporal domain. Results: The model effectively predicts the time-varying concentration behavior of various contrast-medium administration in each organ for different patient models as function of patient size (weight/height) and different injection protocol factors (injection rate and pattern, iodine concentration or volume). The contrast enhanced XCAT patient models was developed based on the concentration of iodine as a function of time after injection. Conclusion: Majority of medical imaging systems take advantage of contrast-medium administration in terms of better image quality, the effect of which was ignored in previous optimization studies. The study enables a comprehensive optimization of contrast

  13. Immediate hypersensitivity to iodinated contrast media: diagnostic accuracy of skin tests and intravenous provocation test with low dose.

    Science.gov (United States)

    Sesé, L; Gaouar, H; Autegarden, J-E; Alari, A; Amsler, E; Vial-Dupuy, A; Pecquet, C; Francès, C; Soria, A

    2016-03-01

    The diagnosis of HSR to iodinated contrast media (ICM) is challenging based on clinical history and skin tests. This study evaluates the negative predictive value (NPV) of skin tests and intravenous provocation test (IPT) with low-dose ICM in patients with suspected immediate hypersensitivity reaction (HSR) to ICM. Thirty-seven patients with suspected immediate hypersensitivity reaction to ICM were included retrospectively. Skin tests and a single-blind placebo-controlled intravenous provocation test (IPT) with low-dose iodinated contrast media (ICM) were performed. Skin tests with ICM were positive in five cases (one skin prick test and five intradermal test). Thirty-six patients were challenged successfully by IPT, and only one patient had a positive challenge result, with a grade I reaction by the Ring and Messmer classification. Ten of 23 patients followed up by telephone were re-exposed to a negative tested ICM during radiologic examination; two experienced a grade I immediate reaction. For immediate hypersensitivity reaction to ICM, the NPV for skin tests and IPT with low dose was 80% (95% CI 44-97%). © 2016 John Wiley & Sons Ltd.

  14. Analytic study of the chain dark decomposition reaction of iodides - atomic iodine donors - in the active medium of a pulsed chemical oxygen-iodine laser: 1. Criteria for the development of the branching chain dark decomposition reaction of iodides

    International Nuclear Information System (INIS)

    Andreeva, Tamara L; Kuznetsova, S V; Maslov, Aleksandr I; Sorokin, Vadim N

    2009-01-01

    The scheme of chemical processes proceeding in the active medium of a pulsed chemical oxygen-iodine laser (COIL) is analysed. Based on the analysis performed, the complete system of differential equations corresponding to this scheme is replaced by a simplified system of equations describing in dimensionless variables the chain dark decomposition of iodides - atomic iodine donors, in the COIL active medium. The procedure solving this system is described, the basic parameters determining the development of the chain reaction are found and its specific time intervals are determined. The initial stage of the reaction is analysed and criteria for the development of the branching chain decomposition reaction of iodide in the COIL active medium are determined. (active media)

  15. SU-E-I-45: Feasibility for Using Iodine Quantification to Assist Diagnosis in Dual Energy Contrast-Enhanced Digital Mammography

    International Nuclear Information System (INIS)

    Hwang, Y; Lin, Y; Tsai, C; Cheung, Y

    2015-01-01

    Purpose: The objective of this study is to develop quantitative calibration between image quality indexes and iodine concentration with dual-energy (DE) contrast-enhanced digital mammography (CEDM) techniques and further serve as the assistance for diagnosis. Methods: Custom-made acrylic phantom with dimensions of 24×30 cm 2 simulated breast thickness from 2 to 6 cm was used in the calibration. The phantom contained matrix of four times four holes of 3 mm deep with a diameter of 15 mm for filling contrast agent with area density ranged from 0.1 to 10 mg/cm 2 . All the image acquisitions were performed on a full-field digital mammography system (Senographe Essential, GE) with dual energy acquisitions. Mean pixel value (MPV), and contrast-to-noise ratio (CNR) were used for evaluating the relationship between image quality indexes and iodine concentration. Iodine map and CNR map could further be constructed with these calibration curves applied pixel by pixel utilized MATLAB software. Minimum iodine concentration could also be calculated with the visibility threshold of CNR=5 according the Rose model. Results: When evaluating the DE subtraction images, MPV increased linearly as the iodine concentration increased with all the phantom thickness surveyed (R 2 between 0.989 and 0.992). Lesions with increased iodine uptake could thus be enhanced in the color-encoded iodine maps, and the mean iodine concentration could be obtained through the ROI measurements. As for investigating CNR performance, linear relationships were also shown between the iodine concentration and CNR (R 2 between 0.983 and 0.990). Minimum iodine area density of 1.45, 1.73, 1.80, 1.73 and 1.72 mg/cm 2 for phantom thickness of 2, 3, 4, 5, 6 cm were calculated based on Rose’s visualization criteria. Conclusion: Quantitative calibration between image quality indexes and iodine concentrations may further serving as the assistance for analyzing contrast enhancement for patient participating the dual

  16. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    Science.gov (United States)

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  17. Evaluation of changes in vertebral body density following administration of contrast medium during routine CT examination

    International Nuclear Information System (INIS)

    Janicek, M.; Bruna, J.; Stenhova, H.

    1984-01-01

    The possibility is discussed of depicting changes in the density of spongiosis of the vertebral body in normal patients after intravenous administration of a bolus of 40 ml 60% Diazetrizoate in the course of a routine CT examination. The average increase in density immediately after the administration of the contrast medium is 12 H (8%), in the course of 10 minutes is reduced to 5 H (4%) against the initial values in native examination. These average changes are statistically significant, in individual patients, however, the increase in density following the administration of a contrast medium fluctuates considerably (from 0.7% to 10%). Only systematic comparison with various pathological conditions will make it possible to assess the possibilities of the evaluation of the structure of the vertebral body in routine CT with the administration of a contrast medium into the blood flow. (author)

  18. Successful transfemoral aortic Edwards(®) SAPIEN(®) bioprosthesis implantation without using iodinated contrast media in a woman with severe allergy to contrast agent.

    Science.gov (United States)

    Leroux, Lionel; Dijos, Marina; Dos Santos, Pierre

    2013-12-01

    Severe anaphylactoid reaction after the use of iodinated contrast media are rare but can contraindicate the use of contrast agent. It was the case of a 53-year-old woman suffering from symptomatic severe aortic stenosis, recused for cardiac surgery because of deleterious effects of chest-wall irradiation, with porcelain aorta. We decided to implant a 23-mm Edwards(®) SAPIEN(®) transcatheter aortic valve via a femoral route without using any contrast media. The implantation was successful after surgical approach of the femoral artery, transesophageal echocardiography guiding, and localization of native leaflets and coronary trunk with catheters. Immediate and one month post-interventional follow-up was favorable and echocardiography showed a good functioning of the aortic bioprosthesis. Although conventional angiography is the best way to visualize the good positioning of the valve before deployment, our case suggests that, in special situations, transfemoral implantation of an Edwards(®) SAPIEN(®) aortic bioprosthesis is feasible without any contrast injection. Copyright © 2012 Wiley Periodicals, Inc.

  19. A Novel Procedure for Rapid Imaging of Adult Mouse Brains with MicroCT Using Iodine-Based Contrast.

    Directory of Open Access Journals (Sweden)

    Ryan Anderson

    Full Text Available High-resolution Magnetic Resonance Imaging (MRI has been the primary modality for obtaining 3D cross-sectional anatomical information in animals for soft tissue, particularly brain. However, costs associated with MRI can be considerably high for large phenotypic screens for gross differences in the structure of the brain due to pathology and/or experimental manipulations. MicroCT (mCT, especially benchtop mCT, is becoming a common laboratory equipment with throughput rates equal or faster than any form of high-resolution MRI at lower costs. Here we explore adapting previously developed contrast based mCT to image adult mouse brains in-situ. We show that 2% weight per volume (w/v iodine-potassium iodide solution can be successfully used to image adult mouse brains within 48 hours post-mortem when a structural support matrix is used. We demonstrate that hydrogel can be effectively used as a perfusant which limits the tissue shrinkage due to iodine.

  20. Use of iohexol as a gastrointestinal contrast medium in the dog

    International Nuclear Information System (INIS)

    Agut, A.; Sanchez-Valverde, M.A.; Lasaosa, J.M.; Murciano, J.; Molina, F.

    1993-01-01

    Iohexol was administered orally in five dogs. The dose, gastrointestinal (GI) transit time, appearance of mucosal patterns and side effects were studied. Three different doses (525, 700, 875 mgI/kg) were used in each dog at 1-week intervals. GI transit time was rapid. In each dose, gastric emptying commenced immediately after administration of the contrast medium, and was completed within 30–60 min with doses of 525–700 mgI/kg and 90–120 min with 875 mgI/kg. Large intestinal filling was observed within 60-90 min. In the majority of studies, the mucosal border appeared as a thin homogeneous halo of lucency surrounding the more opaque bowel lumen contents. The contrast intensity was not adequate with the lowest dose. The image quality did not deteriorate along the GI tract. No adverse reactions were found. Iohexol is an alternative GI contrast medium in the dog when contrast media are contraindicated

  1. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300); Intravenoese Kontrastmittel-Applikation bei aelteren Patienten - Anwendungsbeobachtung von Iopentol (Imagopaque trademark 300)

    Energy Technology Data Exchange (ETDEWEB)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D. [Zentrum fuer Klinische Radiologie, Kliniken Essen-Sued (Germany)

    2004-12-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  2. MRI of the liver with the new contrast medium Gd-BOPTA

    International Nuclear Information System (INIS)

    Vogl, T.J.; Pegios, W.; Balzer, J.; Lissner, J.; Pirovano, G.

    1992-01-01

    A phase 1 study on 8 normals has been carried out to determine the effectiveness and safety during MRI of a new hepatobiliary contrast medium Gd-BOPTA for causing enhancement of the upper abdominal organs. Gradient echo sequences (flash), T 1 and T 2 -weighted spin echo sequences and turbo-flash sequences were used. The contrast medium was given as a single infusion in various concentrations (0.005, 0.05, 0.1 and 0.2 mmol/kg body weight). Optimal contrast of liver parenchyma was obtained with a dose of 0.05-0.1 mmol/kg body weight, resulting in contrast increase of 149.1% during gradient echo sequences and 107.8% during T 1 spin echo sequences. In general, the increased contrast lasted for about two hours. Because of the biliary and renal excretion there was an enormous increase in signal intensity of the bile ducts and a significant increase in the kidneys and ureters. The results of the first in-vivo-trial of Gd-BOPTA encourages the performance of further clinical studies of this new hepatobiliary contrast medium. (orig.) [de

  3. Experimental irradiation of the rat ureter: The effects of field size and the presence of contrast medium on incidence and latency of hydronephrosis

    International Nuclear Information System (INIS)

    Knowles, J.F.; Trott, K.R.

    1987-01-01

    Following X-irradiation of a 1.5 cm length of rat ureter, hydronephrosis developed after doses down to 10 Gy. The estimated ED 50 was 11.8 Gy. In the dose range 37.4 Gy to 17.5 Gy there was a significant increase in latency with decreasing dose, but at lower doses the latency did not increase further. Reducing the length of ureter irradiated to 0.5 cm or 0.8 cm caused a decrease in incidence of hydronephrosis and longer latency periods. The ED 50 for rats iradiated to 0.5 cm of ureter was 29.6 Gy. The possibility that secondary radiation produced as a result of interaction between X-radiation and iodinated contrast medium might affect the radiation induction of hydronephrosis was investigated. No difference was found between groups of rats irradiated with or without injection of contrast media. 39 refs.; 4 figs

  4. Evaluation of Physical Capture Efficiency and Disinfection Capability of a Novel Iodinated Filter Medium

    National Research Council Canada - National Science Library

    Ratnesar, Shanna; Wu, Chang-Yu; Wander, Joe; Lundgren, Dale; Farrah, Sam; Wanakule, Prinda; Blackburn, Matthew; Lan, Mei-Fang

    2006-01-01

    ...% that of the glass-fiber HEPA filter (0.0054 in H2O/(in/min) vs 0.065 in H2O/(in/min)). Biological disinfection by the medium was evaluated using Micrococcus luteus and Echerichia coli vegetative bacterial cells...

  5. Do Iodine Contrast Media Compounds Used for Medical Imaging Contribute to the Formation of Iodinated Disinfection By-Products in Drinking Water?

    Science.gov (United States)

    Iodinated disinfection byproducts (DBPs) have recently gained attention due to their cyto- and genotoxicity and increased formation in drinking water treated with chloramine, which has become an increasingly popular disinfectant in the United States. One of these—iodoacetic acid...

  6. Oral contrast medium in PET/CT: should you or shouldn't you?

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Dickson, John C.; Townsend, Caroline; Croasdale, Ian; Syed, Rizwan; Nagabushan, Nagesh; Hain, Sharon F.; Ell, Peter J.; Bomanji, Jamshed B.

    2005-01-01

    It has been suggested that the use of computed tomography (CT) positive contrast agents has led to attenuation-induced artefacts on 18 F-fluorodeoxyglucose positron emission tomography ( 18 F-FDG PET/CT) systems. Consequently, centres may withhold the use of such agents. Whilst there is theoretical evidence to support the aforementioned claim, the clinical relevance of the induced artefacts has not been widely established. Moreover, the potential benefits of bowel enhancement on PET/CT have yet to be formally evaluated. We therefore prospectively examined PET/CT studies to assess whether the use of oral contrast medium induces clinically relevant artefacts and whether the use of these agents is diagnostically helpful. Over a 2-month period, 18 F-FDG PET/CT images were prospectively reviewed from 200 patients following Gastrografin administration 2 h prior to examination. Both a radiologist and a nuclear medicine physician reviewed the images for contrast medium-mediated clinically relevant artefacts. Artefacts were sought on the CT attenuation-corrected images and were compared with the appearance on non-attenuated-corrected images. The number of examinations in which the oral contrast aided image interpretation was also noted. There were no oral contrast medium-induced clinically significant artefacts. In 38 of the 200 patients, oral contrast aided image interpretation (owing to differentiation of mass/node from bowel, discrimination of intestinal wall from lumen or definition of the anatomy of a relevant site). In 33 of these 38 patients, the anatomical site of interest was the abdomen/pelvis. The use of oral contrast medium in 18 F-FDG PET studies should not be withheld as it improves image interpretation and does not produce clinically significant artefacts. (orig.)

  7. Lecithine as an adjuvant in resorption of contrast medium in oral cholecystography

    International Nuclear Information System (INIS)

    Lindgren, I.

    1978-01-01

    No or poor filling of the gallbladder was obtained in 21 patients at cholecystography. They were re-examined after 10 days or later with the addition of lecithine to the contrast medium. The filling of the gallbladder, which was without abnormality, was improved in all cases. The mechanism of this effect is discussed. (Auth.)

  8. Craniopharyngiomas - the utility of contrast medium enhancement for MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Hald, J.K.; Eldevik, O.P.; Brunberg, J.A.; Chandler, W.F.

    1994-01-01

    To evaluate the efficacy of i.v. contrast medium administration in MR imaging at 1.5 T in patients with craniopharyngiomas, MR studies of 10 men and 6 women with pathologically proven craniopharyngiomas were made. The MR images were obtained as 3- to 5-mm-thick coronal (n=13) or axial (n=3) T1-weighted images (T1WI) prior to an following i.v. Gd-DTPA administration. Proton density-(PD) and T2-weighted images (T2WI) were also obtained. Conspicuity of tumor margins, cystic versus solid components, size, location and effect upon adjacent structures were separately characterized in all imaging sequences. In 6 patients contrast medium-enhanced T1WI, PD and T2WI demonstrated cystic tumor components not seen on unenhanced T1WI. There were significant differences (p<0.004) on 2-tailed Student's t-test comparing tumor conspicuity on contrast medium-enhanced T1WI with unenhanced T1WI, PD and T2WI. Optimal tumor delineation on MR imaging of patients with craniopharyngiomas justifies the use of i.v. contrast medium. (orig.)

  9. Digital subtraction angiography and intraarterial contrast medium injection for coronary examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tobio, R; Kallmeyer, C; Castello, J

    1985-01-01

    Digital subtraction angiography (DSA) is an established method of vasography, most extensively used as i.v. DSA. Intraarterial injection, however, applying selective or non-selective contrast medium injection, seems to be at least as important a technique although it has not yet met with corresponding interest. The article explains advantages of the technique for angiographic examinations, in particular of coronary angiography.

  10. A phantom test of proton-induced dual-energy X-ray angiography using iodinated contrast media

    International Nuclear Information System (INIS)

    Oguri, Y.; Hasegawa, J.; Ogawa, M.; Kaneko, J.; Sasa, K.

    2007-01-01

    Characteristic-line radiation from heavy metal targets bombarded by MeV proton beams has been tested as an X-ray source for dual-energy K-edge subtraction imaging for human angiography (blood vessel imaging) based on iodinated contrast media. To utilize the strong absorption by iodine (Z=53) at its K-absorption edge (33.2 keV), we used K α -line of La (lanthanum, Z=57) at 33.4 keV. As a reference, also K α X emission of Sn (tin, Z=50) at 25.2 keV was employed. Metallic plates of La and Sn were irradiated by 7-MeV protons to produce these characteristic X-rays. Energy-subtraction method was tested using Lucite phantoms which contain aqueous solutions of KI (potassium iodide) with different concentrations. Also Ca(H 2 PO 4 ) 2 powder was stuffed in these phantoms to simulate bones. The transmission images of the phantoms were recorded on imaging plates. During the exposure, the energy spectra of the X-rays were monitored by a CdTe detector. We found that the contrast of images of iodide solutions taken with La X-rays was higher than that with Sn X-rays. Also the energy subtraction procedure was successfully applied to reduce the graphical noise due to the bones and inhomogeneity of the soft tissue. However, to apply the present method to actual clinical use, the X-ray intensity must be increased by several orders of magnitude. Also the transmission of the 'lower-energy' photons has to be a few orders higher for imaging of objects as thick as human chest. (author)

  11. Transient partial amnesia complicating cardiac and peripheral arteriography with nonionic contrast medium

    International Nuclear Information System (INIS)

    Yildiz, A.; Yencilek, E.; Apaydin, F.D.; Duce, M.N.; Oezer, C.; Atalay, A.

    2003-01-01

    The aim of this study was to present a case of disruption of the blood-brain barrier during the coronary and lower extremity angiographies with radiological and clinical findings. This condition was secondary to intraarterial use of a nonionic, monomeric contrast medium. A total of 450 cc contrast media was used. Computed tomography examination showed contrast enhancement of the right occipital and frontoparietal cortical regions, which returned to normal one day after. The patient also fully recovered from the neurological symptoms within 24 h. We discussed the possible mechanism for blood-brain barrier disruption in this case. (orig.)

  12. Transient partial amnesia complicating cardiac and peripheral arteriography with nonionic contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Yildiz, A.; Yencilek, E.; Apaydin, F.D.; Duce, M.N.; Oezer, C. [Dept. of Radiology, Mersin Ueniv. Tip Fakueltesi Sokak Mersin (Turkey); Atalay, A. [Dept. of Cardiology, Mersin Ueniv. Tip Fakueltesi Sokak Mersin (Turkey)

    2003-12-01

    The aim of this study was to present a case of disruption of the blood-brain barrier during the coronary and lower extremity angiographies with radiological and clinical findings. This condition was secondary to intraarterial use of a nonionic, monomeric contrast medium. A total of 450 cc contrast media was used. Computed tomography examination showed contrast enhancement of the right occipital and frontoparietal cortical regions, which returned to normal one day after. The patient also fully recovered from the neurological symptoms within 24 h. We discussed the possible mechanism for blood-brain barrier disruption in this case. (orig.)

  13. Spiral CT and optimization of the modalities of the iodinated intravenous contrast material: Experimental studies in human pathology

    International Nuclear Information System (INIS)

    Bonaldi, V.

    1998-01-01

    Spiral (or helical) CT represents the most recent improvement in the field of computed assisted tomography (CAT scan). The capabilities of this new imaging modality are much superior to these of conventional CT scanning; then result from the rapid acquisition and from the volumetric nature of the derived data set. The short time of data acquisition had made mandatory the revision of protocols for intravenous administration of iodinated contrast material. By the means of several studies, carried out on pathologic and healthy patients, we have attempted to improve knowledge in factors influencing CT attenuation values after injection of contrast material, in the aim of improving contrast administration performed during spiral CT scanning. Anatomical landmarks that we have studied till now have been liver, the pancreas, the kidney and the cervical spine. In addition, a paired based methodology has been used. The volumetric set of data derived from spiral CT scanning leads to optimal post-processing tasks, the most interesting being related to cine-display and multiplanar reformatting; both modalities have been evaluated, about the pancreas and the musculo-skeletal system respectively. Conversely, this new modality, as for other imaging modalities, is responsible for additional costs derived from restless increase in the number of images to be dealt with and from the occurrence of new tasks (in post-processing particularly). The place of spiral CT in diagnostic strategies among other modern imaging modalities should be assessed, especially with respect to Magnetic Resonance Imaging (MRI). (author)

  14. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, K.; Reinprecht, P. [Roentgendiagnostisches Zentralinstitut, LKH Klagenfurt (Austria); Kau, T. [Roentgendiagnostisches Zentral Inst., Klagenfurt (Austria); Igerc, I.; Lind, P. [Abt. fuer Nuklearmedizin und Spezielle Endokrinologie, LKH Klagenfurt (Austria)

    2005-06-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk {sup registered}, which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk {sup registered} can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  15. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    International Nuclear Information System (INIS)

    Hausegger, K.; Reinprecht, P.; Kau, T.; Igerc, I.; Lind, P.

    2005-01-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk registered , which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk registered can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  16. Adverse effects to iodinated contrast media in interleukin-2 treated patients; Reacciones adversas a los medio de contraste yodados en pacientes tratados con interleuquina 2

    Energy Technology Data Exchange (ETDEWEB)

    Vias, I.; Nicolas, A. I.; Lopez Picazo, J. M.; Elduayen, B.; Delgado, C.; Ano, M.; Fernande-villa, T.; Garcia del Barrio, L.; Velazquez, P.; Bilbao, J. I. [Universidad de Navarra. Pamplona (Spain)

    2000-07-01

    Interleukin-2 (IL-2) is a potent modulator of immune response that provokes tumor regression in cancer patients. IL-2 may induce sensitization to radiological iodinated contrast media (ICM) and this phenomenon has been rarely reported in literature. We report the increased incidence of adverse reactions to ICM patients treated with systemic IL-2, discuss the possible mechanisms of action, and propose patient management strategies. Retrospective study was conducted in 168 patients treated with subcutaneous IL-2 and 544 patients who did not.CT scans were performed with intravenous administration of 80-160 ml of nonionic ICM with a power injector. The incidence of adverse reactions to ICM among our patients was 7.14%. It differs significantly (p<0.001) from that in the control group (1.28%). Thus, patients treated with IL-2 have a relative risk of 5,6 times (CI 95%; 2.2-13.9). The adverse reactions in IL-2 patients were mild and resolved promptly without treatment in 11 patients. In one patient hypotension required intravenous forced hydration. Patients on IL-2 treatment may be at risk of experiencing contrast induced adverse reactions. Potent of the immune system by IL-2 may increase the potential risk for hypersensitivity or other adverse reactions to ICM. Knowledge of this fact may be valuable in clinical decision making and patient follow-up strategies. (Author) 18 refs.

  17. Effect of barium sulfate contrast medium on rheology and sensory texture attributes in a model food.

    Science.gov (United States)

    Ekberg, O; Bulow, M; Ekman, S; Hall, G; Stading, M; Wendin, K

    2009-03-01

    The swallowing process can be visualized using videoradiography, by mixing food with contrast medium, e.g., barium sulfate (BaSO(4)), making it radiopaque. The sensory properties of foods may be affected by adding this medium. To evaluate if and to what extent sensory and rheological characteristics of mango purée were altered by adding barium sulfate to the food. This study evaluated four food samples based on mango purée, with no or added barium sulfate contrast medium (0%, 12.5%, 25.0%, and 37.5%), by a radiographic method, and measured sensory texture properties and rheological characteristics. The sensory evaluation was performed by an external trained panel using quantitative descriptive analysis. The ease of swallowing the foods was also evaluated. The sensory texture properties of mango purée were significantly affected by the added barium in all evaluated attributes, as was the perception of particles. Moreover, ease of swallowing was significantly higher in the sample without added contrast medium. All samples decreased in extensional viscosity with increasing extension rate, i.e., all samples were tension thinning. Shear viscosity was not as dependent on the concentration of BaSO(4) as extensional viscosity. Addition of barium sulfate to a model food of mango purée has a major impact on perceived sensory texture attributes as well as on rheological parameters.

  18. Radiologic diagnosis of gastro-oesophageal reflux. Comparison of barium and low-density contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G.; Soekjer, H.; Johansson, K.E.; Tibbling, L.

    It has been proposed that the high density of ordinary barium suspension may complicate the radiologic diagnosis of gastro-oesophageal reflux. For this reason P-contrast was developed (Ferring AB); a contrast medium with the same density as water (1 g/cm/sup 3/). A comparison of P-contrast and barium (Mixobar Ventrikel 400 mg/ml) was performed in 82 patients. All patients were examined with both contrast media and the findings were compared with those at reflux test at manometry, endoscopy and 24-hour pH monitoring. Another 40 patients and 15 symptom-free controls were examined with two different amounts of barium, 100 ml and 200 ml, to study if the radiologic diagnosis of reflux varied with the volume of contrast medium administered. P-contrast was found to have no advantages over barium for the diagnosis of gastro-oesophageal reflux. The outcome of the radiologic examination was not influenced by the different volumes of barium used.

  19. Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: Observations in an ex vivo model

    NARCIS (Netherlands)

    L. la Grutta (Ludovico); M. Galia (Massimo); G. Gentile; G. Lo Re (G.); E. Grassedonio (Emanuele); F. Coppolino; E. Maffei (Erica); E. Maresi (E.); A. Lo Casto (A.); F. Cademartiri (Filippo); M. Midiri (Massimo)

    2013-01-01

    textabstractObjective: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. Methods: In six ex vivo left anterior descending coronary arteries immersed in oil, CT

  20. Combined use of contrast media containing iodine and gadolinium for imaging and intervention. A hitherto widely ignored topic in radiological practice

    International Nuclear Information System (INIS)

    Golder, W.

    2012-01-01

    The synchronous use of chemically different contrast media in the same body compartment is a challenge for the radiologist, whether it is scheduled or unexpected. However, to inject contrast media containing iodine and gadolinium at the same time can be a prerequisite for the examination of several organs or organ systems. Unlike other topics of contrast-enhanced imaging procedures, the difficulties encountered with double contrast injections have been widely ignored in the literature. In the absence of reliable data from experimental and clinical studies the radiologist is dependent on case reports, information provided by the contrast media manufacturers, personal communications, mostly scanty personal experiences and a skilful time management, in order to overcome the situation. Only the combination of X-ray, computed tomography and magnetic resonance arthrography can be performed without another thought. However, the more or less synchronous vascular application of contrast media containing iodine and gadolinium requires vigilance. The more seriously ill the patient is, the more caution is advised even if the decision on the combined administration has to be reached urgently. The following overview gives a description of the properties of contrast media containing iodine and gadolinium as far as interactions following simultaneous administration are concerned. Subsequently, the clinically relevant situations and constellations are outlined and analyzed. (orig.) [de

  1. 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model

    Science.gov (United States)

    Holalkere, N-S; Matthes, K; Kalva, S P; Brugge, W R; Sahani, D V

    2011-01-01

    Objective In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml–1) and high-concentration contrast media (HCCM) (370 mg I ml–1) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose. Methods CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml–1), Group B (HCCM; 370 mg I ml–1) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg–1) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test. Results The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose. Conclusion 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced. PMID:21081582

  2. Water as a contrast medium: a re-evaluation using the multidetector-row computed tomography.

    Science.gov (United States)

    Makarawo, Tafadzwa P; Negussie, Edsa; Malde, Sachit; Tilak, Jacqueline; Gayagoy, Jennifer; Watson, Jenna; Francis, Faiz; Lincoln, Denis; Jacobs, Michael J

    2013-07-01

    Water as an intraluminal negative contrast medium produces improved image quality with reduced artefact. However, rapid absorption of oral water in the bowel relative to speed and timing of image capturing has limited its clinical application. These findings predate advances in multidetector-row computed tomography (CT). To re-evaluate differences in image quality, we studied image clarity and luminal distention between the same group of patients who received both a pancreas protocol CT (PPCT) that uses oral water and a conventional positive oral contrast scan. We reviewed 66 patients who had previously undergone both a PPCT and an oral contrast abdominal CT. CT images were independently reviewed by two board-certified radiologists who scored degree of hollow viscus distention and visualization of mural detail using a Likert 5-point scale. Results were evaluated by using the Wilcoxon-signed rank test. Student's t test was applied to evaluate the differences in radiation dosage and Spearman's correlational test was used to evaluate interrater correlation between the radiologists. In comparing the mean radiation dosage, there was no statistical difference between the two protocols, and there was good interrater association with ratios of 0.595 and 0.51 achieved for the PPCT and conventional oral scan, respectively. The Wilcoxon signed-rank test showed statistical differences in the stomach (P contrast medium causing better or equal distention in the bowel and better or equal clarity than routine barium contrast. This calls for a need to reconsider the use of water as a contrast medium in clinical practice.

  3. Update on the renal toxicity of iodinated contrast drugs used in clinical medicine

    Directory of Open Access Journals (Sweden)

    Andreucci M

    2017-05-01

    Full Text Available Michele Andreucci,1 Teresa Faga,1 Raffaele Serra,2 Giovambattista De Sarro,3 Ashour Michael1 1Renal Unit, Department of Health Sciences, 2Interuniversity Center of Phlebolymphology (CIFL, International Research and Educational Program in Clinical and Experimental Biotechnology, Department of Medical and Surgical Sciences, 3Pharmacology Unit, Department of Health Sciences, Magna Graecia University, Catanzaro, Italy Abstract: An important side effect of diagnostic contrast drugs is contrast-induced acute kidney injury (CI-AKI; a sudden decrease in renal function occurring 48–72 hours after injection of a contrast drug that cannot be attributed to other causes. Its existence has recently been challenged, because of some retrospective studies in which the incidence of AKI was not different between subjects who received a contrast drug and those who did not, even using propensity score matching to prevent selection bias. For some authors, only patients with estimated glomerular filtration rate <30 mL/min/1.73 m2 are at significant risk of CI-AKI. Most agree that when renal function is normal, there is no CI-AKI risk. Many experimental studies, however, are in favor of the existence of CI-AKI. Contrast drugs have been shown to cause the following changes: renal vasoconstriction, resulting in a rise in intrarenal resistance (decrease in renal blood flow and glomerular filtration rate and medullary hypoxia; epithelial vacuolization and dilatation and necrosis of proximal tubules; potentiation of angiotensin II effects, reducing nitric oxide (NO and causing direct constriction of descending vasa recta, leading to formation of reactive oxygen species in isolated descending vasa recta of rats microperfused with a solution of iodixanol; increasing active sodium reabsorption in the thick ascending limbs of Henle’s loop (increasing O2 demand and consequently medullary hypoxia; direct cytotoxic effects on endothelial and tubular epithelial cells (decrease

  4. Computed tomography of the cervical spine with iv injection of contrast medium

    International Nuclear Information System (INIS)

    Magnaldi, S.; Pozzi-Mucelli, R.S.; Cova, M.A.; De Morpurgo, P.

    1989-01-01

    Computed Tomography (CT) without contrast medium is largely applied to the study of intervertebral disk pathology in the lumbar spine, but has not been widely accepted in cervical spine, due to technical and anatomical limitations. For these reasons many neuroradiologists still prefer myelography or myelo-CT. CT may yield better results if combined with iv contrast medium injection, which allows a better visualization of disk herniation. This technique is aimed at enhancing the density of the venous plexus which is located close to the intervertebral disk the vertebral bodies and the neural foramina. A better contrast enhancement is thus obtained between the disk and the spinal cord. The authors' experience is based on 61 patients who underwent contrast enhanced CT; in 22 cases myelography and myelo-CT were also performed. The authors describe their technique and the most frequent CT findings of disk hernation: the typical finding includes a focal hypodensity surrounded by a linear blush, due to a posteriorly dislocated epidural vein. The posterior linear blush alone may be present in few cases. Contrast enhanced CT is very useful in the study of disk pathology of the cervical spine, even when compared with myelography and myelo-CT, due the increase in the density of epidural plexus it allows. However, the technique must be very accurate if the same results as those of myelo-CT are to be obtained

  5. Diagnostic capabilities of the contrast medium verografin in liposomes (animal experiments)

    International Nuclear Information System (INIS)

    Rozenberg, O.A.; Khason, K.P.; Aliyakparov, M.T.; Davidenkova, E.F.; Zherbin, E.A.; Akademiya Meditsinskikh Nauk SSSR, Leningrad. Inst. Ehksperimental'noj Meditsiny)

    1985-01-01

    Some examples for the diagnosis of various diseases of liver and spleen after intravenous (cats, dogs) or intraportal (rodents) injection of lecithin-cholesterol liposomes containing the water soluble contrast medium verografin are described. Tumors of 1 mm were found in the spleen of mice with lymphogranulomatosis, hepatomas of 3-5 mm in rats and lesions of 10 mm in cats with turpentine abscesses. The application of liposomes containing radiographic contrast media offers good possibilities for the diagnosis of liver and spleen. (author)

  6. Cytogenetic analysis in peripheral blood lymphocytes after arteriography (exposure to X-rays and contrast medium)

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Popova, L.; Hristova, R.; Hadjidekov, V.

    2006-01-01

    Full text: The purpose of our study is to investigate the cytogenetic effects in peripheral blood lymphocytes of 29 patients who had undergone diagnostic angiography. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13 and 68 years). Cytogenetic analysis was performed in peripheral lymphocytes before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03 - 0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency was used as biomarkers of genotoxicity. The estimated frequency of chromosomal aberrations and micronuclei in peripheral blood lymphocytes of patients after arteriography examination is significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations nearly double after examination and remained constant at 24h analysis. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase of the cytogenetic injury in peripheral blood lymphocytes

  7. Cytogenetic analysis of peripheral blood lymphocytes after arteriography (exposure to x-rays and contrast medium)

    International Nuclear Information System (INIS)

    Popova, L.; Hadjidekova, V.; Karadjov, G.; Agova, S.; Traskov, D.; Hadjidekov, V.

    2005-01-01

    Backgrounds. The purpose of our study is to investigate the cytogenetic analysis findings in peripheral blood lymphocytes of 29 patients who had undergone diagnostic radiography. Methods. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13-68 years). Cytogenetic analyses of peripheral lymphocytes were performed before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03-0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency were used as biomarkers of genotoxicity. Results. The estimated frequency of chromosomal aberrations and micronuclei in the peripheral blood lymphocytes of patients after arteriography examination was significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations was nearly double after examination and proved to be constant in the analysis after 24 hours. Conclusions. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase in cytogenetic damage in peripheral blood lymphocytes. (author)

  8. Immediate adverse reactions to intravenous iodinated contrast media in computed tomography Reacciones adversas inmediatas al contraste yodado intravenoso en tomografía computarizada Reações adversas imediatas ao contraste iodado intravenoso em tomografia computadorizada

    Directory of Open Access Journals (Sweden)

    Beatriz Cavalcanti Juchem

    2007-02-01

    Full Text Available This exploratory-descriptive, non-experimental quantitative research aimed to learn about immediate adverse reactions to intravenous iodinated contrast media in hospitalized patients submitted to computed tomography at a teaching hospital in the South of Brazil. During the study period, all adverse reactions showed mild intensity, at a frequency of 12.5% with ionic iodinated contrast media, and 1% with non-ionic contrast agent. The extravasation of contrast occurred in 2.2% of the injections in a peripheral vein without complications in any of the cases. The results are within the limits cited in international literature and suggest that tomography service professionals should know their own rates of adverse reactions to iodinated contrast agent, as well as the conditions in which they occur, in order to obtain evidence to evaluate the respective care delivery processes.Investigación cuantitativa del tipo exploratorio-descriptivo, de carácter no experimental. El objetivo consistía en conocer las reacciones adversas inmediatas al contraste yodado intravenoso en pacientes internados, sometidos a tomografía computarizada en un hospital escuela del sur de Brasil. Durante el período del estudio, todas las reacciones adversas tuvieron intensidad leve y una frecuencia del 12,5% con la utilización del contraste yodado iónico, y 1% con contraste no iónico. La extravasación del contraste ocurrió en un 2,2% de las inyecciones en vena periférica, no ocasionando complicaciones en ninguno de los casos. Los índices evidenciados en el presente estudio se mantuvieron dentro de los límites que constan en la revisión de literatura y, entre las recomendaciones, se sugiere que los servicios de tomografía conozcan los propios índices de reacciones adversas al contraste yodado y las condiciones en que ocurren, con la finalidad de obtener evidencias para evaluación de los respectivos procesos asistenciales.Pesquisa quantitativa, explorat

  9. Comparative evaluation of the fecal-tagging quality in CT colonography: barium vs. iodinated oral contrast agent.

    Science.gov (United States)

    Nagata, Koichi; Singh, Anand Kumar; Sangwaiya, Minal Jagtiani; Näppi, Janne; Zalis, Michael E; Cai, Wenli; Yoshida, Hiroyuki

    2009-11-01

    The purpose of this evaluation was to compare the tagging quality of a barium-based regimen with that of iodine-based regimens for computed tomographic (CT) colonography. Tagging quality was assessed retrospectively in three different types of fecal-tagging CT colonographic cases: 24 barium-based cases, 22 nonionic iodine-based cases, and 24 ionic iodine-based cases. For the purpose of evaluation, the large intestine was divided into six segments, and the tagging homogeneity of a total of 420 segments (70 patients) was graded by three blinded readers from 0 (heterogeneous) to 4 (homogeneous). For barium-based cases, the average score for the three readers was 2.4, whereas it was 3.4 for nonionic iodine and 3.6 for ionic iodine. The percentages of segments that were assigned scores of 4 (excellent tagging [100%]) were 11.6%, 61.9%, and 72.9% for the barium-based, nonionic iodine-based, and ionic iodine-based regimens, respectively. The homogeneity scores of iodine-based fecal-tagging regimens were significantly higher than those of the barium-based fecal-tagging regimen (P barium-based regimen (P barium-based fecal-tagging regimen. Iodine-based fecal-tagging regimens can provide an appropriate method for use in nonlaxative or minimum-laxative CT colonography.

  10. GE-145, a new low-osmolar dimeric radiographic contrast medium

    International Nuclear Information System (INIS)

    Wistrand, Lars-G.; Rogstad, Astri; Hagelin, Gunnar

    2010-01-01

    Background: Contrast-induced nephrotoxicity is a significant risk when using radiographic contrast media clinically, especially in high risk patients. Consequently, there is a need for a new contrast agent with improved clinical safety with regards to nephrotoxicity. Purpose: To evaluate the physicochemical properties as well as the preclinical safety and biodistribution parameters of the newly developed radiographic contrast medium GE-145. Material and Methods: Standard methods for radiographic contrast media were used for evaluation of physicochemical properties. The acute toxicity in rats was studied at 8, 10, and 12.5 gI/kg, the clinical chemistry parameters were determined, and histology of the kidneys was performed. Biodistribution was studied in rats using 123 I-labeled GE-145. Results: GE-145 is more hydrophilic than iodixanol and has a considerably lower osmolality. The viscosity is similar to that of iodixanol and the protein binding is low. The acute toxicity is similar to that of iodixanol and the biodistribution is similar to that of other radiographic contrast media, showing mainly renal excretion. Kidney histology showed a moderate reversible vacuolization, similar to that of iodixanol. Conclusion: GE-145 exhibits similar preclinical properties to other dimeric radiographic contrast media. In addition, the low osmolality enables an iso-osmolar formulation containing a significantly higher concentration of electrolytes than Visipaque

  11. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke

    International Nuclear Information System (INIS)

    Tijssen, M.P.M.; Stadler, A.A.R.; Zwam, W. van; Graaf, R. de; Postma, A.A.; Hofman, P.A.M.; Oostenbrugge, R.J. van; Klotz, E.; Wildberger, J.E.

    2014-01-01

    To assess the feasibility of dual energy computed tomography (DE-CT) in intra-arterially treated acute ischaemic stroke patients to discriminate between contrast extravasation and intracerebral haemorrhage. Thirty consecutive acute ischaemic stroke patients following intra-arterial treatment were examined with DE-CT. Simultaneous imaging at 80 kV and 140 kV was employed with calculation of mixed images. Virtual unenhanced non-contrast (VNC) images and iodine overlay maps (IOM) were calculated using a dedicated brain haemorrhage algorithm. Mixed images alone, as ''conventional CT'', and DE-CT interpretations were evaluated and compared with follow-up CT. Eight patients were excluded owing to a lack of follow-up or loss of data. Mixed images showed intracerebral hyperdense areas in 19/22 patients. Both haemorrhage and residual contrast material were present in 1/22. IOM suggested contrast extravasation in 18/22 patients; in 16/18 patients this was confirmed at follow-up. The positive predictive value (PPV) of mixed imaging alone was 25 %, with a negative predictive value (NPV) of 91 % and accuracy of 63 %. The PPV for detection of haemorrhage with DE-CT was 100 %, with an NPV of 89 % and accuracy improved to 89 %. Dual energy computed tomography improves accuracy and diagnostic confidence in early differentiation between intracranial haemorrhage and contrast medium extravasation in acute stroke patients following intra-arterial revascularisation. (orig.)

  12. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Tijssen, M.P.M.; Stadler, A.A.R.; Zwam, W. van; Graaf, R. de; Postma, A.A. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Hofman, P.A.M. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, MhENS School for Mental Health and Neuroscience, Maastricht (Netherlands); Oostenbrugge, R.J. van [Maastricht University Medical Centre, Department of Neurology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, CARIM School for Cardiovascular Diseases, P.O. Box 616, Maastricht (Netherlands); Klotz, E. [Siemens Healthcare Sector, Computed Tomography, Forchheim (Germany); Wildberger, J.E. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, CARIM School for Cardiovascular Diseases, P.O. Box 616, Maastricht (Netherlands)

    2014-04-15

    To assess the feasibility of dual energy computed tomography (DE-CT) in intra-arterially treated acute ischaemic stroke patients to discriminate between contrast extravasation and intracerebral haemorrhage. Thirty consecutive acute ischaemic stroke patients following intra-arterial treatment were examined with DE-CT. Simultaneous imaging at 80 kV and 140 kV was employed with calculation of mixed images. Virtual unenhanced non-contrast (VNC) images and iodine overlay maps (IOM) were calculated using a dedicated brain haemorrhage algorithm. Mixed images alone, as ''conventional CT'', and DE-CT interpretations were evaluated and compared with follow-up CT. Eight patients were excluded owing to a lack of follow-up or loss of data. Mixed images showed intracerebral hyperdense areas in 19/22 patients. Both haemorrhage and residual contrast material were present in 1/22. IOM suggested contrast extravasation in 18/22 patients; in 16/18 patients this was confirmed at follow-up. The positive predictive value (PPV) of mixed imaging alone was 25 %, with a negative predictive value (NPV) of 91 % and accuracy of 63 %. The PPV for detection of haemorrhage with DE-CT was 100 %, with an NPV of 89 % and accuracy improved to 89 %. Dual energy computed tomography improves accuracy and diagnostic confidence in early differentiation between intracranial haemorrhage and contrast medium extravasation in acute stroke patients following intra-arterial revascularisation. (orig.)

  13. Adding the power of iodinated contrast media to the credibility of mammography in breast cancer diagnosis.

    Science.gov (United States)

    Tsigginou, Alexandra; Gkali, Christina; Chalazonitis, Athanasios; Feida, Eleni; Vlachos, Dimitrios Efthymios; Zagouri, Flora; Rellias, Ioannis; Dimitrakakis, Constantine

    2016-11-01

    Dual-energy contrast-enhanced spectral mammography (CESM) represents a relatively new diagnostic tool adjunct to mammography. The aim of this study was to strengthen the breast imaging-reporting and data system (BIRADS) classification score in order to improve early breast cancer diagnosis. For this reason, we propose a sum score, termed malignancy potential score (MPS), incorporating the standard BIRADS score and our proposed CESM score. From September 2014 to September 2015, 216 females (age range, 26-85 years; mean age 54.6 years) underwent CESM evaluation of mammographic findings that were primarily assessed as BIRADS 2-5. 10 of these patients had bilateral findings; a total of 226 lesions were examined. High-energy image evaluation was based on the intensity of contrast enhancement of the lesion compared with background enhancement, categorized as Type -1, 0, 1 or 2 enhancement. Histopathology reports were compared with imaging assessment. 98 of 226 lesions were malignant and 128 of 226 lesions were benign. The area under the curve was 0.843, 0.888 and 0.917 for mammographic BIRADS score, CESM score and MPS, respectively, with p-value mammography or CESM alone. MPS empowers the credibility of the digital mammography BIRADS score and our proposed type of enhancement in dual-energy CESM and is a diagnostic tool that increases the accuracy rate in early breast cancer diagnosis.

  14. Iodinated contrast agent-induced nephropathy; Mit jodhaltigen Kontrastmitteln induzierte Nephropathie

    Energy Technology Data Exchange (ETDEWEB)

    Erley, C. [St. Joseph-Krankenhaus Berlin, Berlin (Germany)

    2007-09-15

    Contrast-induced nephropathy (CIN) is a well-known complication of therapeutic and diagnostic procedures requiring contrast administration and accounts for 10% of acute renal failure in hospitalized patients. Although the incidence of this complication is relatively low, its consequences can be catastrophic. The development of CIN is associated with increased length of hospital stay, an increased requirement for acute dialysis, and an increased risk of death. Preexisting renal dysfunction, age, diabetes, congestive heart failure, and volume of administered contrast are all associated with a risk of developing CIN. Despite a large number of clinical trials that have evaluated prophylaxis strategies for CIN, no uniform strategies have been developed so far. The use of N-acetyl-L-cysteine (NAC) or theophylline in specific subgroups of patients has been shown to reduce dialysis requirement and mortality in patients undergoing angiographic procedures. Hemofiltration has also shown positive results. In this review we will discuss the epidemiology and the risk factors for CIN and the evidence for commonly employed prophylaxis strategies, and we will provide general recommendations with respect to CIN prevention and management. A practicable strategy to prevent CIN includes: correct identification of individuals at greatest risk, thorough evaluation of whether other diagnostic maneuvers could be employed instead (i.e., sonography), application of low-osmolar contrast media at the minimum acceptable dose, stopping potential nephrotoxic drugs (NSAID), hydration with sodium chloride 0.9% 1 ml/kg per h i.v. 12 h before and after CM application, administration of acetylcysteine 600 mg twice the day before and after (in cases of emergency investigation and high-risk patients 1200 mg i.v.), and theophylline (250-350 mg) the day before and the day after CM application (in cases of emergency investigation 5 mg/kg i.v.). (orig.) [German] Die Kontrastmittelnephropathie (contrast

  15. The Incidence, Classification, and Management of Acute Adverse Reactions to the Low-Osmolar Iodinated Contrast Media Isovue and Ultravist in Contrast-Enhanced Computed Tomography Scanning.

    Science.gov (United States)

    Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing

    2016-03-01

    Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning.Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370.Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae.Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is higher with Ultravist-370 than with Isovue-370, but this difference is limited only to the mild AARs. The incidence of AARs could be affected by multiple factors.

  16. In-vitro effects of tri-iodinated X-ray contrast media on blood coagulation, fibrinolysis and complement system

    International Nuclear Information System (INIS)

    Blanke, D.

    1982-01-01

    In-vitro experiments with Jodipamid, Jothalamat and Diatrizoat served the purpose of determining influences of contrast media on blood coagulation, fibrinolysis and the complement system. For all three contrast media investigated the effect noted was dose-dependent and was only brought about by concentrations higher than physiological ones. Liver-pathway Jodipamid was seen to have a much stronger effect than the two renal-pathway contrast media Jothalamat and Diatrizoat, which is probably due to the different protein binding capacities. In detail, the results with Jodipamid were as follows: a sharp fall in thrombinogen, a distinct decrease in fibrinogen both in the immunological and functional test, but only delayed decrease in complement factor C 4. Fibrinolytic fission products were found after applying the dose of 30 mM, as compared to 400 mM for the renal-pathway contrast media. Furthermore the functional tests (F I and F II) with Jothalamat and Diatrizoat showed only slight effects, the immunological ones (F I and C 4) none at all. The influence of the contrast media on factors I and II is interpreted by the author as an inhibition of fibrin polymerization. What seems to be the verification of fibrinolytic fission products is explained by a non-specific agglutination reaction, the decrease in C 4 by contrast-medium-induced protein denaturation. (orig./MG) [de

  17. Magnetic Resonance Imaging in degenerative disease of the lumbar spine: Fat Saturation technique and contrast medium.

    Science.gov (United States)

    D'Aprile, Paola; Nasuto, Michelangelo; Tarantino, Alfredo; Cornacchia, Samantha; Guglielmi, Giuseppe; Jinkins, J Randy

    2018-01-19

    To examine both anterior and posterior elements of the lumbar spine in patients with low back pain using MRI T2-weighted sequences with Fat Saturation (FS) and contrast enhanced T1-weighted sequences with FS. Two thousand eight hundred and twenty (2820) patients (1628 male, 1192 female, mean age 54) presenting low back pain underwent MRI standard examination (Sagittal T1w TSE and T2w TSE, axial T1 SE) with the addition of sagittal and axial T2w Fat Sat (FS) sequences. Among all the patients, 987 (35%) have been studied adding Contrast Enhanced (CE) T1w FS sequences after administration of contrast medium. Among 987 patients studied with contrast medium, we found: active-inflammatory intervertebral osteochondrosis in 646 (65%) patients; degenerative-inflammatory changes in facet joints (facet joint effusion, synovitis, synovial cysts) in 462 (47%); spondylolysis in 69 (7%); degenerative-inflammatory changes of the flava, interspinous and supraspinous ligaments in 245 (25%); inflammatory changes of posterior perispinal muscles in 84 (8%) patients. In patients with suspected no-disc-related low back pain, the implementation of T2w FS and CE T1w FS sequences to the standard MR protocol could allow a better identification of degenerative-inflammatory changes more likely associated to the pain.

  18. Sensation of smell and taste during intravenous injection of iodinated contrast media in CT examinations

    Science.gov (United States)

    Yamaguchi, Naoto; Yamaguchi, Aiko; Nagasawa, Naoki; Taketomi-Takahashi, Ayako; Suto, Takayuki; Tsushima, Yoshito

    2017-01-01

    Objective: To assess the incidence and types of sensation of smell and taste during i.v. injection of five kinds of contrast media (CM) in CT examinations. Methods: 735 patients who underwent contrast-enhanced CT (CE-CT) between 14 March 2016 and 5 April 2016 were enrolled. Medical staff asked patients whether they felt heat sensation and sensation of smell and taste during i.v. injection of CM (one of the following: iopromide, iomeprol, iopamidol, iohexol and ioversol) after their CE-CT. If the patients stated having felt the sensation of smell or taste, they were also asked what kind of smell or taste they sensed. Next, 30 ml of each CM was poured into high-purity pet cups for radiological technologists to smell directly. Radiological technologists were asked whether or not each CM had any smell. Results: The sensations of smell and taste incidence for iopromide were 24.3% and 18.9%, respectively, which were significantly higher than those for other CM (p < 0.05). The highest incidence of the sensation of smell was medicine-ish, and the most frequently noted taste was bitterness. All radiological technologists could directly smell only iopromide, which has an ether group on a side chain and fewer hydroxyl groups. Conclusion: Iopromide showed a higher incidence of sensation of smell and taste than other CM. Advances in knowledge: This was the first investigation of sensation of smell and taste during i.v. injection of CM, and a specific CM showed a higher incidence, which is suspected to be due to its chemical structure. PMID:27805431

  19. Application of synchrotron radiation phase-contrast microtomography with iodine staining to Rhodnius prolixus head during ecdysis period

    Science.gov (United States)

    Sena, G.; Nogueira, L. P.; Braz, D.; Colaço, M. V.; Azambuja, P.; Gonzalez, M. S.; Tromba, G.; Mantuano, A.; Costa, F. N.; Barroso, R. C.

    2018-05-01

    Synchrotron radiation phase-contrast microtomography (SR-PHC-CT) has become an important tool in studies of insects, mainly Rhodinius prolixus, the insect vector of Chagas disease. A previous work has shown that SR-PHC-CT is an excellent technique in studies about the ecdysis process of R.prolixus head. The term ecdysis refers to the set of behaviors by which an insect extracts itself from an old exoskeleton. The exoskeleton formation is indispensable for the evolutionary success of insect species, so failure to complete ecdysis will, in most cases result in death, making this process an excellent target in the search for new insect pest management strategies. Understanding the behavior of the ecdysis process is fundamental for the non-proliferation of Chagas disease. Despite it has been possible to identify the moulting process in the first work, main structures of the R.prolixus head could not be identified. In this work, it was developed a staining protocol which enabled the identification of these important structures using Iodine at SYRMEP beamline of ELETTRA. In the 3D images, it was possible to segment essential structures in the process of ecdysis. These structures have never been presented previously in the moulting period with SR-PHC-CT.

  20. Value of 100 kVp scan with sinogram-affirmed iterative reconstruction algorithm on a single-source CT system during whole-body CT for radiation and contrast medium dose reduction: an intra-individual feasibility study.

    Science.gov (United States)

    Nagayama, Y; Nakaura, T; Oda, S; Tsuji, A; Urata, J; Furusawa, M; Tanoue, S; Utsunomiya, D; Yamashita, Y

    2018-02-01

    To perform an intra-individual investigation of the usefulness of a contrast medium (CM) and radiation dose-reduction protocol using single-source computed tomography (CT) combined with 100 kVp and sinogram-affirmed iterative reconstruction (SAFIRE) for whole-body CT (WBCT; chest-abdomen-pelvis CT) in oncology patients. Forty-three oncology patients who had undergone WBCT under both 120 and 100 kVp protocols at different time points (mean interscan intervals: 98 days) were included retrospectively. The CM doses for the 120 and 100 kVp protocols were 600 and 480 mg iodine/kg, respectively; 120 kVp images were reconstructed with filtered back-projection (FBP), whereas 100 kVp images were reconstructed with FBP (100 kVp-F) and the SAFIRE (100 kVp-S). The size-specific dose estimate (SSDE), iodine load and image quality of each protocol were compared. The SSDE and iodine load of 100 kVp protocol were 34% and 21%, respectively, lower than of 120 kVp protocol (SSDE: 10.6±1.1 versus 16.1±1.8 mGy; iodine load: 24.8±4versus 31.5±5.5 g iodine, p<0.01). Contrast enhancement, objective image noise, contrast-to-noise-ratio, and visual score of 100 kVp-S were similar to or better than of 120 kVp protocol. Compared with the 120 kVp protocol, the combined use of 100 kVp and SAFIRE in WBCT for oncology assessment with an SSCT facilitated substantial reduction in the CM and radiation dose while maintaining image quality. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues.

    Science.gov (United States)

    Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M

    2016-06-01

    Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. © 2016 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  2. Dialysis and contrast media

    International Nuclear Information System (INIS)

    Morcos, Sameh K.; Thomsen, Henrik S.; Webb, Judith A.W.

    2002-01-01

    In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and molecular size, protein binding, hydrophilicity, and electrical charge of the contrast medium. Generally, several hemodialysis sessions are needed to removal all contrast medium, whereas it takes 3 weeks for continuous ambulatory dialysis to remove the agent completely. There is no need to schedule the dialysis in relation to the injection of iodinated or MR contrast media or the injection of contrast agent in relation to the dialysis program. Hemodialysis does not protect poorly functioning kidneys against contrast-medium-induced nephrotoxicity. Simple guidelines are given. (orig.)

  3. Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol

    Energy Technology Data Exchange (ETDEWEB)

    Trad, Henrique Simao; Boasquevisque, Gustavo Santos; Giacometti, Tiago Rangon; Trad, Catherine Yang; Zoghbi Neto, Orlando Salomao; Trad, Clovis Simao, E-mail: hsimtrad@gmail.com [Central de Diagnostico Ribeirao Preto (CEDIRP), Ribeirao Preto, SP (Brazil)

    2016-03-15

    Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m{sup 2} to 41.8 kg/m{sup 2}. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations. (author)

  4. ''Iodine delivery rate'' with catheterangiography under pressure conditions of hand injection

    International Nuclear Information System (INIS)

    Busch, H.P.; Stocker, K.P.

    1998-01-01

    Purpose: The aim of this study was to record the flow-rate and to calculate the 'iodine delivery rate' (IDR) of contrast media of various viscosities when the contrast media are injected by hand. Methods: Five different catheters for coronary angiography were tested with the injection system Medral Mark V Plus. Injections were performed with pressures of 100, 200 and 400 PSI. The contrast media examined were Imeron 350, Imeron 400, Omnipaque 350 and Ultravist 370. The IDR was calculated on the basis of the measured flow rate and the Iodine content of the contrast medium. Results: As was expected, the IDR was higher as the pressure increased. In addition to the iodine content the viscosity of the contrast medium is a very important factor for the IDR. At both 100 PSI and 200 PSI the increase of the IDR was higher with Imeron 350 than with Imeron 400. The comparison of contrast media with identical iodine contents but differing viscosities (Imeron 350, Omnipaque 350) clearly showed that the IDR depended on viscosity. Conclusion: The 'iodine delivery rate' is a decisive factor in the opacification of arterial vessels. Both iodine content and viscosity of a contrast medium are important for the IDR. Because of the low pressure at manual injection, contrast media with low viscosities should be used. A further possibility to increase the IDR is warming-up the contrast medium to body temperature. (orig.) [de

  5. In vitro experiments for the development of a high density (HD) barium sulfate contrast medium

    International Nuclear Information System (INIS)

    Klein, J.

    1986-01-01

    In vitro experiments with the high-density (HD) barium meal Falibaryt HD are described. Several charges of BaSO 4 were tested together with certain additives influencing dispersion, stability of the suspension, flowability, surface tension etc. Particle size spectra were measured by the manufacturer, VEB Fahlberg-List. With a simple PVC test plate containing several grooves simulating small details (areae gastricae) the diagnostic capabilities of the HD contrast medium were evaluated in an in vitro test. The developed barium meal Falibaryt HD is in its physical and chemical parameters comparable with Prontobario-HD, one of the best HD barium meals. (author)

  6. Studies on the consistency of internally taken contrast medium for pancreas CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Mimura, Seiichi; Tahara, Seiji; Kitayama, Takuichi; Inamura, Keiji; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1985-02-01

    A problem of Pancreatic CT scanning is the discrimination between the pancreas and the adjacent gastrointestinal tract. Generally we administer a dilution of gastrografin internally to make the discrimination. The degree of dilution has been decided by experience at each hospital. When the consistency of the contrast medium is low in density, an enhancement effect cannot be expected, but when the consistency is high, artifacts appear. We have experimented on the degree of the dilution and CT-No to decide the optimum consistency of gastrografin for the diagnosis of pancreatic disease. Statistical analysis of the results show the optimum dilution of gastrografin to be 1.5%.

  7. Avaliação do conhecimento de médicos não-radiologistas sobre reações adversas aos contrastes iodados Evaluation of nonradiologist physicians' knowledge about adverse reactions to iodinated contrast media

    Directory of Open Access Journals (Sweden)

    Ronald Trindade

    2007-10-01

    Full Text Available OBJETIVO: Avaliar o conhecimento dos médicos não-radiologistas sobre reações adversas ao meio de contraste iodado, sua prevenção e as condições clínicas que aumentam seu risco. MATERIAIS E MÉTODOS: Estudo transversal com 203 médicos não-radiologistas (assistentes, residentes e estagiários de várias especialidades, utilizando um questionário com dez questões de múltipla escolha abordando profilaxia, fatores de risco e condutas relacionadas ao desenvolvimento de reações adversas aos meios de contraste iodados. Os resultados foram analisados com o programa Statistic Package for Social Sciences, Windows®, versão 12.0. RESULTADOS: Asma, alergia alimentar, ansiedade e doença isquêmica do coração foram considerados fatores de risco por 80,9%, 78,9%, 5,9% e 4,1% dos participantes, respectivamente. Para 23,4% dos médicos, não há contra-indicações absolutas ao uso do meio de contraste iodado. As condutas profiláticas em pacientes com reação prévia ao meio de contraste iodado e em diabéticos em uso de metformina foram corretamente indicadas por 84,5% e 53,7% dos participantes, respectivamente. As questões abordando nefropatia induzida por meio de contraste iodado, uso de anti-sépticos tópicos iodados em pacientes com história de reação adversa ao meio de contraste iodado e ansiedade foram acertadas por 86,1%, 45,5%, e 5,9% dos participantes, respectivamente. CONCLUSÃO: Os médicos não-radiologistas demonstraram conhecimento razoável sobre reações adversas aos meios de contraste iodados. É necessária melhor integração e comunicação entre radiologistas e médicos das demais especialidades.OBJECTIVE: To evaluate the nonradiologist physicians' knowledge about adverse reactions to iodinated contrast media, as well as prevention and associated risk factors. MATERIALS AND METHODS: A transversal study was developed with 203 nonradiologist physicians (assistants, residents and trainees of different specialties

  8. Intraoperative iodinated contrast swallow with CT-scan delayed control for detection of early complications in laparoscopic gastric bypass: A case series of 260 cases

    Directory of Open Access Journals (Sweden)

    Vincenzo Consalvo, M.D.

    2017-01-01

    Conclusions: This study gives a contribute to the existing issue of fast track in bariatric surgery for the early diagnosis of complications and patients' readmission or non-discharge. In conclusion, the use of intraoperative iodinated water soluble contrast swallow and abdominal CT-scan at 48 h was a safe and accurate test in order to detect and treat any potential early surgical complication in LRYGB.

  9. The association between use of metformin and change in serum CO_2 level after administration of contrast medium

    International Nuclear Information System (INIS)

    Kim, S.K.; Jung, J.; Jung, J.H.; Kim, K.Y.; Baek, J.-H.; Hahm, J.R.

    2016-01-01

    Aim: To evaluate the changes in serum creatinine and total CO_2 levels in patients receiving metformin during administration of contrast medium. Materials and methods: Patient records from January 2012 to December 2012 after the administration of contrast medium were reviewed retrospectively. A total of 924 patients were included for the final analysis. Of them, 105 received metformin during contrast medium administration, 112 were taking other oral hypoglycaemic agents, and 707 patients were not diabetic (controls). Results: No significant change in total CO_2 levels was detected (p=0.678). Metabolic acidosis was present in 33 (31.4%) metformin users, 31 (28.6%) other oral hypoglycaemic agent users, and 153 (21.6%) control patients. In the present logistic regression analysis, age, baseline levels of creatinine, and total CO_2 levels were associated with metabolic acidosis after contrast medium exposure. Conclusion: These data indicate the presence of a coexisting risk factor, other than metformin use, associated with metabolic acidosis after contrast medium exposure. No relationship was found between the use of metformin and metabolic acidosis during contrast medium exposure. - Highlights: • The use of metformin was not associated with metabolic acidosis after contrast exposure. • The coexisting risk factors for metabolic acidosis were present in patient with metabolic acidosis after contrast exposure. • There is a need to consider the maintenance of metformin during a CT scan in patients with a low risk for lactic acidosis.

  10. A prospective evaluation of contrast and radiation dose and image quality in cardiac CT in children with complex congenital heart disease using low-concentration iodinated contrast agent and low tube voltage and current.

    Science.gov (United States)

    Hou, Qiao-Ru; Gao, Wei; Sun, Ai-Min; Wang, Qian; Qiu, Hai-Sheng; Wang, Fang; Hu, Li-Wei; Li, Jian-Ying; Zhong, Yu-Min

    2017-02-01

    To the assess image quality, contrast dose and radiation dose in cardiac CT in children with congenital heart disease (CHD) using low-concentration iodinated contrast agent and low tube voltage and current in comparison with standard dose protocol. 110 patients with CHD were randomized to 1 of the 2 scan protocols: Group A (n = 45) with 120 mA tube current and contrast agent of 270 mgI/ml in concentration (Visipaque ™ ; GE Healthcare Ireland, Co., Cork, UK); and Group B (n = 65) with the conventional 160 mA and 370 mgI/ml concentration contrast (Iopamiro ® ; Shanghai Bracco Sine Pharmaceutical Corp Ltd, Shanghai, China). Both groups used 80 kVp tube voltage and were reconstructed with 70% adaptive statistical iterative reconstruction algorithm. The CT value and noise in aortic arch were measured and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate image quality. Contrast and radiation dose were recorded. There was no difference in age and weight between the two groups (all p > 0.05). The iodine load and radiation dose in Group A were statistically lower (3976 ± 747 mgI vs 5763 ± 1018 mgI in iodine load and 0.60 ± 0.08 mSv vs 0.77 ± 0.10 mSv in effective dose; p  0.05), and with good agreement between the two observers. Comparing the surgery results, the diagnostic accuracy for extracardiac and intracardiac defects for Group A was 96% and 92%, respectively, while the corresponding numbers for Group B were 95% and 93%. Compared with the standard dose protocol, the use of low tube voltage (80 kVp), low tube current (120 mA) and low-concentration iodinated contrast agent (270 mgI/ml) enables a reduction of 30% in iodine load and 22% in radiation dose while maintaining compatible image quality and diagnostic accuracy. Advances in knowledge: The new cardiac CT scanning protocol can largely reduce the adverse effects of

  11. [Protective effect of sodium bicarbonate on radiological contrast medium-induced nephropathy in rats].

    Science.gov (United States)

    Vattimo, Maria deFátima Fernandes; dos Santos, Juliana Guareschi

    2013-06-01

    Radiological iodinated contrasts (IC) agents cause acute kidney injury (AKI). To evaluate the renoprotective effect of sodium bicarbonate (Bic) on renal function (creatinine clearance [Clcr], Jaffé, and Clcr mLmin -1 x100 g-1) and the oxidative profile (peroxide excretion, urinary peroxides, urinary malondialdehyde, FOX-2 expression, and thiobarbituric acid reactive substance [TBARS; nmol/mg Cr]) in rats treated with an IC agent. Adult male Wistar rats weighing 250-300 g were treated once daily for 5 days with one of the following treatments: saline (0.9%, 3 mL.kg-1xday-1 intraperitoneally [i.p.]), IC agent (sodium and meglumine ioxitalamate, 3 mL/kg, i.p.), Bic + Saline (3-mL/kg Bic, i.p., 1 h before and after saline treatment), and Bic + IC (3-ml/kg Bic, i.p., 1 h before and after the IC treatment). The IC agent induced AKI, and the antioxidant renoprotective effect of Bic was confirmed (Clcr/TBARS/urinary peroxide: saline group, 0.59+/- 0.03/0.11 +/-0.02/1.29+/- 0.24; Bic+Saline group, 0.58 +/-0.03/0.13+/- 0.02/1.32+/- 0.64; IC group, 0.22 +/- 0.02/0.19 +/- 0.02/4.77 +/- 0.24; Bic +Clgroup, 0.51+/- 0.04/0.13+/- 0.3/1.80+/- 0.04; p<0.05). The protective effect of Bic in the IC-induced AKI was confirmed; hence, Bic administration may be considered as a therapeutic option for patients undergoing IC-enhanced radiography.

  12. A prospective evaluation of the contrast, radiation dose and image quality of contrast-enhanced CT scans of paediatric abdomens using a low-concentration iodinated contrast agent and low tube voltage combined with 70% ASIR algorithm.

    Science.gov (United States)

    Wang, Xiaoxia; Zhong, Yumin; Hu, Liwei; Xue, Lianyan; Shi, Meihua; Qiu, Haisheng; Li, Jianying

    2016-09-01

    To quantitatively and subjectively assess the image quality of and radiation dose for an abdominal enhanced computed tomography (CT) scan with a low tube voltage and a low concentration of iodinated contrast agent in children. Forty-eight patients were randomised to one of the two following protocols: Group A (n=24, mean age 46.96±44.65 months, mean weight 15.71±9.11 kg, BMI 16.48±2.40 kg/m(2) ) and Group B (n=24, mean age 41.33±44.59 months, mean weight 18.15±17.67 kg, BMI 17.50±3.73 kg/m(2) ). Group A: 80 kVp tube voltage, 270 mg iodine (I)/mL contrast agent (Visipaque, GE Healthcare) and images were reconstructed using 70% adaptive statistical iterative reconstruction (ASIR). Group B: 100 kVp tube voltage, 370 mg I/mL contrast agent (Iopamiro, Bracco) and images were reconstructed using 50% ASIR. The volume of the contrast agent was 1.30 mL/kg in both Groups A and B. The degree of enhancement and noise in the abdominal aorta (AO) in the arterial phase (AP) and the portal vein (PV) in the portal venous phase (PVP) was measured; while the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the AO and PV were calculated. A 5-point scale was used to subjectively evaluate the image quality and image noise by two radiologists with more than 10 years of experience. Dose-length product (DLP) (mGy-cm) and CTDIvol (mGy) were calculated. Objective measurements and subjective quality scores for the two groups were compared using paired t-tests and Mann-Whitney U tests, respectively. There was no significant difference in age, weight or body mass index (BMI) between the two groups (all P>.5). The iodine load in Group A (5517.3±3197.2 mg I) was 37% lower than that in Group B (8772.1±8474.6 mg I), although there was no significant difference between them (P=.111). The DLP and the CT dose index (CTDIvol ) for Group A were also lower than for Group B, but were not statistically significantly different (DLP, 104 mGy-cm±45.81 vs 224.5

  13. Magnesium sulfate as an oral contrast medium in magnetic resonance imaging of the small intestine.

    Science.gov (United States)

    Shi, Hao; Liu, Cun; Ding, Hong Yu; Li, Chun Wei

    2012-03-01

    To explore the use of magnesium sulfate (MgSO4) as an oral contrast medium (CM) in MRI of the small intestine. By comparing MgSO4 SNRs at different concentrations, we determined that 2.5% MgSO4 is the ideal concentration for small bowel MRI. Twenty volunteers underwent MRI after drinking 2.5% MgSO4. Thirty-one patients with clinical suspicion of small intestinal pathology underwent both MRI and the air-barium contrast examination. The patient's tolerance, side effects and complications were noted. 2.5% MgSO4 can decrease the absorption of water and fully fill the enteric cavity, thereby increasing the contrast between the intestinal wall and lumen and facilitating radiographic examination of the small bowel. The mean diameter of the small intestine was 19.8±1.21 mm in the 20 volunteers consuming 2.5% MgSO4 and 12.7±0.84 mm in the 20 volunteers given water. There was a significant difference (P0.05) in side effects between MgSO4 and water groups. Small intestinal MRI was successfully performed in all 31 patients, who were also examined by the double contrast barium, which gave almost identical diagnoses to MRI in all cases except for 1 patient with small intestinal hemorrhage. MRI with 2.5% MgSO4 can demonstrate intestinal abnormalities. Therefore, 2.5% MgSO4 solution is an ideal oral CM for small bowel MRI. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Utility of gadolinium as a contrast medium in endovascular therapeutic procedures; Utilidad del gadolinio como medio de contraste en procedimientos terapeuticos endovasculares

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, R.; Pardo, M. D.; Gorriz, E.; Gallardo, L. (Hospital de Gran Canaria Dr. Negrin); Carreira, J. M. (Universidad de Santiago de Compostela)

    2001-07-01

    To assess the utility of gadolinium associated with CO{sub 2}, as a contrast medium in angiographic studies related to endovascular therapeutic procedures in patients with suboptimal renal function. Between January 2000 and June 2001, endovascular treatments using CO{sub 2} and gadolinium as contrast medium were performed in 10 patients presenting renal function deterioration (creatinine>1.5 mg/ml). A mean dose of 42 ml of gadolinium was administered. The images acquired in diagnostic and therapeutic studied were satisfactory in every case. There was no evidence of significant increases in the previous urea and creatine levels when measured 24, 48 and 72 hours after the procedure. In combination with CO{sub 2} gadolinium is a useful contrast medium for endovascular therapeutic procedures in patients with suboptimal renal function. (Author) 21 refs.

  15. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Science.gov (United States)

    Restuccia, Nancy; Torrisi, Lorenzo

    2018-01-01

    The synthesis of Au and Ag nanoparticles (NP) though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM) measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials) and in vivo (in mice), were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  16. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Directory of Open Access Journals (Sweden)

    Restuccia Nancy

    2018-01-01

    Full Text Available The synthesis of Au and Ag nanoparticles (NP though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials and in vivo (in mice, were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  17. Effects of barium sulfate as a contrast medium to enterocutaneous fistulas

    International Nuclear Information System (INIS)

    Pelster, F.W.; Reichelt, S.; Arndt, M.; Eising, E.G.

    1989-01-01

    Fistulation following thoracic and epigastric interventions are conservatively treated, as a rule, because of the high rate of complications expected from reoperation. With properly functioning anastomotic transit, insufficiencies usually undergo spontaneous healing, within four to six weeks. Enterocutaneous fistulae developed in 29 of 271 patients with intrathoracic oesophagastric or oesophagojejunal anastomosis. Syringeal ramification into pleural or abdominal cavities were eliminated by means of an absorbable contrast medium, before barium sulphate was orally administered to all patients. Thoracic fistulae were closed after 21.8 days on average, while 20.3 days was the average period required for closure of epigastric fistulae. Barium sulphate was found to stimulate fistular tissue granulation, so that obliteration of the fistular system occurred much sooner, as compared to conservative treatment. The patient's quality of life can thus be improved, and hospitalisation can be shortened. Neither locally delimited nor systemic complications were observed in any of the cases described. (author)

  18. Renal effects of the non-ionic contrast medium iopentol after intravenous injection in healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Jakobsen, J.A.; Berg, K.J.; Waaler, A.; Andrew, E. (Rikshospitalet, Oslo (Norway). Dept. of Radiology Rikshospitalet, Oslo (Norway). Renal Section Nycomed A/S, Oslo (Norway). Dept. of Clinical Research and Development)

    1990-01-01

    Renal effects of the new non-ionic contrast medium iopentol in increasing doses were assessed and compared with the effects of physiologic saline. Twenty-four healthy male volunteers, allocated to three dose groups, were given iopentol intravenously in doses of 0.3, 0.6, and 1.2 g I/kg body weight, respectively. The highest dose group was also given physiologic saline separately as a control. The diuresis increased in all groups, most in the highest dose group, and with a concomitant fall of urine osmolality and increase in osmolar clearance. A slight decrease of serum osmolality, creatinine and urea occurred at 3 hours due to hemodilution. The glomerular filtration rate was unaffected by iopentol. The urinary excretion of albumin and {beta}{sub 2}-microglobulin was unchanged. However, urinary N-acetyl-{beta}-glucosaminidase and alkaline phosphatase increased significantly, most in the highest dose group. All changes were reversible. (orig.).

  19. Clinical cardiovascular experiences with iopamidol: a new non-ionic contrast medium

    International Nuclear Information System (INIS)

    Partridge, J.B.; Robinson, P.J.; Turnbull, C.M.; Stoker, J.B.; Morrison, G.W.; Boyle, R.M.

    1981-01-01

    Iopamidol, a new non-ionic water-soluble contrast medium, has been compared with standard ionic media in a number of cardiovascular applications. It is stable in aqueous solution, is much less viscous and only slightly more osmolar than metrizamide. Compared to sodium meglumine diatrizoate in a series of 40 coronary arteriograms, it produced a consistent and highly significant decrease in the incidence and severity of hypotension and bradycardia following intracoronary injection. In the same group and in 62 children undergoing ventricular or great vessel angiocardiography, a subjective assessment of patient reaction showed that iopamidol was better tolerated than the ionic medium. There was a very strong patient preference for iopamidol in a group of 10 of the adult patients who had also consented to femoral artery injections of both media. Throughout these series there was no detectable difference in arterial image quality between the media. Venous phase opacification during arterioportography was assessed in 11 cases comparing iopamidol with sodium meglumine iothalamate. No significant difference was found. We conclude that iopamidol is clearly preferable to ionic media for routine cardiovascular applications. (author)

  20. Volatilization of iodine from vegetation

    International Nuclear Information System (INIS)

    Amiro, B.D.; Johnston, F.L.

    1989-01-01

    Gaseous emissions of iodine were measured from bean plant foliage. A gamma-emitting iodine tracer, Na 125 I, was taken up by the plants from a hydroponic growth medium and released to a cuvette atmosphere. The dynamics of the flux were studied using a flow-through gamma detector. The relationship between leaf radioactive tracer activity and growth-medium activity was linear, as was the relationship between the iodine flux and both leaf and growth-medium activity. Iodine flux and leaf conductance to water responded similarly to changes in light levels, suggesting that the stomata may partially control the flux. The flux was inhibited by aeration of the hydroponic growth media, and we postulate that methylation causes the iodine flux. Iodine emissions from living vegetation probably contribute < 0.1% to the stable iodine concentration in the atmosphere above terrestrial areas. However, this pathway may be a direct route for radioactive iodine transport from contaminated soils to the atmosphere. (author)

  1. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Oztoprak, I. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey)], E-mail: oztoprak@cumhuriyet.edu.tr; Guemues, C.; Oztoprak, B. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey); Engin, A. [Department of Infectious Diseases, Cumhuriyet University Faculty of Medicine, Sivas (Turkey)

    2007-12-15

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas.

  2. Experimental and clinical studies of non-ionic isoosmolality contrast medium (iohexol 140), 2

    International Nuclear Information System (INIS)

    Tajima, Natsuki

    1986-01-01

    Based upon the results of fundamental investigation by the author, that non-ionic isoosmolality contrast medium, iohexol 140 mgI/ml, has almost no adverse effect on the shape of erythrocyte. Intraarterial digital subtraction angiography (IADSA) was performed with this agent in clinical practice. A total number of 344 injections was performed in 100 cases, and angiographic opacifications, subjective reactions and hemodynamic alterations were analysed. The contrast opacifications were excellent or good except five injections on which angiographies were afflicted by misregistration artifact. As for adverse reactions there were only 14 cases who complained mild heat sensations, whereas no pain was experienced. The intensity of local heat sensation at peripheral arteriographies was statistically milder than that caused by diatrizoate 292 mgI/ml (p < 0.001) and iohexol 300 mgI/ml (p < 0.001). The continuous monitorings of femoral blood pressure and electrocardiogram following 16 cases of thoracic aortography, 17 abdominal aortographies and 80 peripheral arteriographies revealed that iohexol 140 mgI/ml caused significantly less effects on decrease of both systolic and diastolic blood pressure and increase of heart rate. Thus it was concluded that iohexol 140 mgI/ml was well suited for IADSA as it caused no pain, good opacification quality and minimum hemodynamic effects. (author)

  3. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    International Nuclear Information System (INIS)

    Oztoprak, I.; Guemues, C.; Oztoprak, B.; Engin, A.

    2007-01-01

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas

  4. Arterial and venous blood pressure and blood flow following femoral angiography with a new non-ionic contrast medium

    International Nuclear Information System (INIS)

    Nyman, U.; Almen, T.

    1978-01-01

    At femoral angiography in dogs the effects of a new non-ionic contrast medium (C29) were compared with those of one non-ionic medium (metrizamide) and one ionic medium (meglumine/sodium diatrizoate) in current use. In the leg subjected to angiography the pressure gradient over the peripheral vessels decreased and the femoral blood flow increased. The changes induced by the ionic medium were significantly greater than those induced by metrizamide and C29, whereas no significant difference between the two non-ionic media was recorded. (Auth.)

  5. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  6. The Preinterventional Cystatin-Creatinine-Ratio: A Prognostic Marker for Contrast Medium-Induced Acute Kidney Injury and Long-Term All-Cause Mortality.

    Science.gov (United States)

    Lüders, Florian; Meyborg, Matthias; Malyar, Nasser; Reinecke, Holger

    2015-01-01

    Contrast medium-induced acute kidney injury (CI-AKI) is an important iatrogenic complication following the injection of iodinated contrast media. The level of serum creatinine (SCr) is the currently accepted 'gold standard' to diagnose CI-AKI. Cystatin C (CyC) has been detected as a more sensitive marker for renal dysfunction. Both have their limitations. The role of the preinterventional CyC-SCr ratio for evaluating the risk for CI-AKI and long-term all-cause mortality was retrospectively analyzed in the prospective single-center 'Dialysis-versus-Diuresis trial'. CI-AKI was defined and staged according to the Acute Kidney Injury Network classification. Three hundred and seventy-three patients were included (average age 67.4 ± 10.2 years, 16.4% women, 29.2% with diabetes mellitus, mean baseline glomerular filtration rate 56.3 ± 20.2 ml/min/1.73 m(2) [as estimated by Chronic Kidney Disease Epidemiology Collaboration Serum Creatinine Cystatin C equation], 5.1% ejection fraction high significant association between preinterventional CyC-SCr ratio and long-term all-cause mortality (mean follow-up 649 days, hazards ratio 4.096, 95% CI 1.625-10.329, p = 0.003). The preinterventional CyC-SCr ratio is independently associated with CI-AKI and highly significant associated with long-term mortality after heart catheterization. © 2015 S. Karger AG, Basel.

  7. Electrochemical reductive dehalogenation of iodine-containing contrast agent pharmaceuticals: Examination of reactions of diatrizoate and iopamidol using the method of rotating ring-disc electrode (RRDE).

    Science.gov (United States)

    Yan, Mingquan; Chen, Zhanghao; Li, Na; Zhou, Yuxuan; Zhang, Chenyang; Korshin, Gregory

    2018-06-01

    This study examined the electrochemical (EC) reduction of iodinated contrast media (ICM) exemplified by iopamidol and diatrizoate. The method of rotating ring-disc electrode (RRDE) was used to elucidate rates and mechanisms of the EC reactions of the selected ICMs. Experiments were carried at varying hydrodynamic conditions, concentrations of iopamidol, diatrizoate, natural organic matter (NOM) and model compounds (resorcinol, catechol, guaiacol) which were used to examine interactions between products of the EC reduction of ICMs and halogenation-active species. The data showed that iopamidol and diatrizoate were EC-reduced at potentials < -0.45 V vs. s.c.e. In the range of potentials -0.65 to -0.85 V their reduction was mass transfer-controlled. The presence of NOM and model compounds did not affect the EC reduction of iopamidol and diatrizoate but active iodine species formed as a result of the EC-induced transformations of these ICMs reacted readily with NOM and model compounds. These data provide more insight into the nature of generation of iodine-containing by-products in the case of reductive degradation of ICMs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Endovascular revascularization of TASC C and D femoropopliteal occlusive disease using carbon dioxide as contrast

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Cynthia de Almeida; Teivelis, Marcelo Passos; Kuzniec, Sergio; Fukuda, Juliana Maria; Wolosker, Nelson [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2016-07-01

    To analyze the results of ten angioplasties of TASC C and D femoropopliteal lesions using CO{sub 2} as primary contrast in patients with no formal contraindication to iodine, aiming to decrease allergic reactions and potential nephrotoxicity in high-risk patients. We describe the results of ten angioplasties of TASC C and D femoropopliteal lesions using CO{sub 2} as primary contrast in patients with high risk for open revascularization and no formal contraindication to iodine. We analyzed feasibility of the procedures, complications, quality of the angiographic images, clinical and surgical outcomes, and costs of C and D lesions treated using CO{sub 2} as contrast medium. The use of CO{sub 2} in C and D lesions needed iodine complementation in most of the cases (nine cases) but decreased the potential nephrotoxicity of iodine contrast medium by the reduction of its volume in this group of high-risk patients. The extension of the arterial lesions was the factor that most contributed to the need for iodine supplementation due to the difficulty to visualize the refill after a long arterial occlusion. The use of CO{sub 2} as contrast in patients with C and D lesions with no restriction for iodine contrast medium was an alternative that did not dismiss the need of iodine supplementation in most of the cases, but could decrease the potential nephrotoxicity of iodine constrast medium.

  9. Synthesis and Preclinical Characterization of a Cationic Iodinated Imaging Contrast Agent (CA4+) and Its Use for Quantitative Computed Tomography of Ex Vivo Human Hip Cartilage.

    Science.gov (United States)

    Stewart, Rachel C; Patwa, Amit N; Lusic, Hrvoje; Freedman, Jonathan D; Wathier, Michel; Snyder, Brian D; Guermazi, Ali; Grinstaff, Mark W

    2017-07-13

    Contrast agents that go beyond qualitative visualization and enable quantitative assessments of functional tissue performance represent the next generation of clinically useful imaging tools. An optimized and efficient large-scale synthesis of a cationic iodinated contrast agent (CA4+) is described for imaging articular cartilage. Contrast-enhanced CT (CECT) using CA4+ reveals significantly greater agent uptake of CA4+ in articular cartilage compared to that of similar anionic or nonionic agents, and CA4+ uptake follows Donnan equilibrium theory. The CA4+ CECT attenuation obtained from imaging ex vivo human hip cartilage correlates with the glycosaminoglycan content, equilibrium modulus, and coefficient of friction, which are key indicators of cartilage functional performance and osteoarthritis stage. Finally, preliminary toxicity studies in a rat model show no adverse events, and a pharmacokinetics study documents a peak plasma concentration 30 min after dosing, with the agent no longer present in vivo at 96 h via excretion in the urine.

  10. [Treatment with metformin in type 2 diabetes mellitus - new routines when renal function is reduced and in connection with administration of iodine contrast media].

    Science.gov (United States)

    Sterner, Gunnar; Frid, Anders

    2018-04-03

    Metformin is eliminated through glomerular filtration and tubular secretion in the kidneys. New guidelines recommend use of metformin down to a GFR of 30 mL/min under the condition that the dose is adjusted. As the risk of inducing lactic acidosis is very low in connection with administration of iodine contrast media, new recommendations in Sweden say that metformin must be stopped only when GFR is below 45 mL/min. Determination of metformin levels in serum is useful to guide therapeutic dose when GFR is low but also to confirm that lactic acidosis is caused by metformin.

  11. Intravenous Contrast Medium Administration for Computed Tomography Scan in Emergency: A Possible Cause of Contrast-Induced Nephropathy

    International Nuclear Information System (INIS)

    Sonhaye, Lantam; Kolou, Bérésa; Tchaou, Mazamaesso; Amadou, Abdoulatif; Assih, Kouméabalo; N'Timon, Bidamin; Adambounou, Kokou; Agoda-Koussema, Lama; Adjenou, Komlavi; N'Dakena, Koffi

    2015-01-01

    The goal of this study was to assess risk for CIN after CT Scan during an emergency and to identify risk factors for the patient. Prospective review of all patients admitted to the emergency room (ER) of the Teaching Hospital of Lomé (Togo) during a 2-year period. CIN was defined as an increase in serum creatinine by 0.5 mg/dL from admission after undergoing CT Scan with intravenous contrast. A total of 620 patients underwent a CT Scan in the emergency room using intravenous contrast and 672 patients took the CT Scan without intravenous contrast. Out of the patients who received intravenous contrast for CT Scan, three percent of them developed CIN during their admission. Moreover, upon discharge no patient had continued renal impairment. No patient required dialysis during their admission. The multivariate analysis of all patients who had serial creatinine levels (including those who did not receive any contrast load) shows no increased risk for acute kidney injury associated intravenous contrast (odds ratio = 0.619, p value = 0.886); only diabetes remains independent risk factor of acute kidney injury (odds ratio = 6.26, p value = 0.031)

  12. Computed tomography of kidney with diuretics. A method for avoiding artifact due to nonionic contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hiromura, Tadao; Terae, Satoshi; Takamura, Akio; Mizoe, Junetsu (Obihiro Kosei Hospital, Hokkaido (Japan)); Morita, Yutaka; Irie, Goro

    1989-07-01

    We devised a method for avoiding beam-hardening artifacts, which interfere with enhanced CT images of kidney due to nonionic contrast medium. The radiographic effect and the frequency of beam-hardening artifacts on enhanced CT of kidney were studied by prospective comparison among three groups: a group of 20 patients examined with furosemide (f-d.CT), a group of 20 patients examined without diuretics (non-d.CT) and a group of 20 patients examined after water intake (w-d.CT). In all patients of f-d.CT group, the renal parenchyma from the cortex to the papilla was almost evently enhanced, free from artifacts. The density of the renal papilla and pelvis in non-d.CT and w-d.CT groups was significantly higher than that in f-d.CT group, and artifacts were also observed in 14 (70%) of non-d.CT group and 12 (60%) of w.d.CT group, respectively. Satisfactory CT of kidney free from artifacts was obtained by f-d.CT, providing easy evaluation of renal pelvic or peripelvic lesions. In conclusion, this technique can be used in those pathologic cases of renal pelvis or peripelvic region, that are not clear on routine CT because of artifacts. (author).

  13. Hydration for the prevention of contrast medium-induced nephropathy. An update

    International Nuclear Information System (INIS)

    Heinrich, M.; Uder, M.

    2006-01-01

    Contrast medium-induced nephropathy (CIN) continues to be one of the most common causes of hospital-acquired acute renal failure. Since most of the clinical studies on the prophylactic use of different drugs to prevent CIN produced disappointing results, hydration remains the mainstay of prophylaxis. A number of recent prospective randomized trials provided further evidence of the effectiveness of hydration and relevant information regarding the optimization of hydration protocols. It was shown that a bolus hydration solely during examination is not sufficient to prevent CIN. In addition, isotonic 0.9% saline was superior to the commonly used halfisotonic 0.45% saline in another trial. An outpatient hydration protocol including oral hydration before the examination followed by forced intravenous hydration over 6 hrs. beginning 30 to 60 min. prior to examination seems to be comparable to the usual hydration over 24 hrs. Another hydration protocol, which could also be very attractive especially for outpatients, included the infusion of sodium bicarbonate. In a recent trial, hydration with sodium bicarbonate, given as a bolus for 1 hr. prior to examination followed by an infusion for 6 hrs. after examination, was more effective than hydration with sodium chloride for the prophylaxis of CIN. However, there is still a lack of large-scale, multi-center trials comparing different hydration protocols and investigating their influence on clinically relevant endpoints such as mortality or the need for dialysis. (orig.)

  14. Cytogenetic effects of cardioangiography on blood lymphocytes in children and in vitro effects of contrast medium and low dose radiation

    International Nuclear Information System (INIS)

    Nikula, E.; Kiviniitty, K.

    1987-01-01

    Structural chromosome aberrations were analysed in the peripheral blood lymphocytes of 15 children, aged 1 to 13 years, before, immediately after, 24 hours after and 6 to 8 months after cardioangiographic examination. Statistically significant increases were only demonstrated in the frequency of gaps and, consequently, in the frequency of aberrant cells immediately after cardioangiography. Most of the chromosome damage clearly disappeared within 24 hours. In addition, whole blood cultures were exposed in vitro to low dose radiation, a contrast medium, and radiation together with the contrast medium. No statistically significant differences could be observed in the chromosome aberration frequencies. It was concluded that the modern radiographic procedure, which uses very low radiation doses and less contrast medium, does not cause a consistent, permanent increase of chromosomal damage in the lymphocytes of children. However, the situation may be different if the child undergoes many radiography examinations or the radiation doses are high. (orig./MG)

  15. Duplex-assisted carotid artery stenting without administration of contrast medium for patients with chronic kidney disease or allergic reaction.

    Science.gov (United States)

    Mizowaki, Takashi; Fujita, Atsushi; Imahori, Taichiro; Uyama, Atsushi; Inoue, Satoshi; Kohta, Masaaki; Hamaguchi, Hirotoshi; Sasayama, Takashi; Hosoda, Kohkichi; Kohmura, Eiji

    2016-07-01

    We aimed to investigate the safety and feasibility of duplex-assisted carotid artery stenting (CAS) without administration of contrast medium for the prevention of adverse reactions. Fifteen patients (9 % of all CASs) with severe carotid stenosis (≥70 %) associated with chronic kidney disease (CKD) (stage ≥3) or allergy to contrast medium underwent duplex-assisted CAS without administration of contrast medium over 4 years. The procedural success rate and perioperative complication rates were compared between the duplex-assisted CAS (n = 15) and conventional CAS (n = 153) groups. The technical success rate was 100 % in both groups. Combined stroke or death rates during the post-procedural period did not differ significantly between the duplex-assisted CAS group (0/15, 0 %) and conventional CAS group (4/153, 2.6 %). None of the 14 patients with CKD in the duplex-assisted CAS group experienced further deterioration of renal function. The mean surface radiation dose of participants in the duplex-assisted CAS group (n = 13, 312 ± 131 mGy) was significantly lower than that of the conventional CAS group (n = 31, 1036 ± 571 mGy) (p duplex-assisted CAS group (156 ± 39.7 min) and the conventional CAS group (156 ± 37.4 min). Duplex-assisted CAS without administration of contrast medium could be an alternative option in selected patients deemed to be at high risk for renal failure from nephrotoxic contrast medium or who have an allergy to contrast medium.

  16. Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function.

    Science.gov (United States)

    Nagayama, Yasunori; Tanoue, Shota; Tsuji, Akinori; Urata, Joji; Furusawa, Mitsuhiro; Oda, Seitaro; Nakaura, Takeshi; Utsunomiya, Daisuke; Yoshida, Eri; Yoshida, Morikatsu; Kidoh, Masafumi; Tateishi, Machiko; Yamashita, Yasuyuki

    2018-05-01

    To evaluate the image quality, radiation dose, and renal safety of contrast medium (CM)-reduced abdominal-pelvic CT combining 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE) in patients with renal dysfunction for oncological assessment. We included 45 patients with renal dysfunction (estimated glomerular filtration rate  60 ml per lmin per 1.73 m 2 ) who underwent standard oncological abdominal-pelvic CT (600 mgI kg -1 , 120-kVp, filtered-back projection) were included as controls. CT attenuation, image noise, and contrast-to-noise ratio (CNR) were compared. Two observers performed subjective image analysis on a 4-point scale. Size-specific dose estimate and renal function 1-3 months after CT were measured. The size-specific dose estimate and iodine load of 80-kVp protocol were 32 and 41%,, respectively, lower than of 120-kVp protocol (p 0.05). No significant kidney injury associated with CM administration was observed. 80-kVp abdominal-pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal-pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.

  17. Enhancement effects of test injection with a small amount of MR contrast medium in the oral and maxillofacial region

    International Nuclear Information System (INIS)

    Yanagi, Yoshinobu; Asaumi, Jun-ichi; Konouchi, Hironobu; Hisatomi, Miki; Matsuzaki, Hidenobu; Murakami, Jun; Maki, Yuu; Unetsubo, Teruhisa; Kishi, Kanji

    2006-01-01

    Purpose: To examine whether the signal intensity of dynamic contrast-enhanced MRI (DCE-MRI) is altered by test injection of 1 ml of contrast medium, and if so, whether this change affects the DCE-MRI analysis. Materials and methods: Six healthy volunteers were examined by DCE-MRI using a Magnevist syringe and/or an Omniscan syringe for the injection of contrast medium. Each scan was performed 10 times using steady-state free precession (3D-FISP), a sequence for DCE-MRI, before and after intravenous injection of 1 ml of the contrast medium. The internal pterygoid muscle, masseter muscle, tongue, parotid gland, submandibular gland, bone marrow of the mandible, subcutaneous adipose tissue, and common carotid artery were determined to be regions of interest (ROI), and the ROI internal average signal intensity was measured. The 10 data sets obtained before or after contrast medium administration for each ROI were evaluated using the paired t-test. Results: The test injection increased the signal intensities of six of eight ROIs, with all 20 experiments in the submandibular gland showing significant differences. There was no significant difference in the two ROIs corresponding to the carotid artery and subcutaneous adipose tissue of the cheek. Conclusions: The enhanced signal intensity in the tissue might have been caused by the small amount of contrast medium in the test injection. To eliminate this discrepancy caused by the test injection, a pre-contrast scan should be performed when the average signal intensity of an ROI is measured. We therefore believe that the data obtained before a test injection may be important in the analysis of DCE-MRI

  18. Which Iodine concentration in chest CT? - A prospective study in 300 patients

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Aachen (Germany); University Hospital, RWTH Aachen University, Aachen (Germany); Behrendt, Florian F.; Eddahabi, Mohammed A.; Das, Marco; Guenther, Rolf W.; Mahnken, Andreas H. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Aachen (Germany); Knackstedt, Christian [RWTH Aachen University Hospital, Department of Cardiology, Pulmonology and Angiology, Aachen (Germany); Stanzel, Sven [RWTH Aachen University Hospital, Institute of Medical Statistics, Aachen (Germany); Seidensticker, Peter [Bayer Schering Pharma AG, Berlin (Germany); Wildberger, Joachim E. [University Hospital Maastricht, Department of Radiology, Maastricht (Netherlands)

    2008-12-15

    In computed tomography(CT) several contrast media with different iodine concentrations are available. The aim of this study is to prospectively compare contrast media with iodine concentrations of 300, 370 and 400 mg iodine/ml for chest- CT. 300 consecutive patients were prospectively enrolled, under a waiver of the local ethics committee. The first (second, third) 100 patients, received contrast medium with 300(370, 400)mg iodine/ml. Injection protocols were adapted for an identical iodine delivery rate(1.3 mg/s) and total iodine load(33 g) for all three groups. Standardized MDCT of the chest (16 x 0.75 mm, 120 kVp, 100 mAseff.) was performed. Intravascular attenuation values were measured in the pulmonary trunk and the ascending aorta; subjective image quality was rated on a 3-point-scale. Discomfort during and after injection was evaluated. There were no statistically significant differences in contrast enhancement comparing the three contrast media at the pulmonary trunk(p = 0.3198) and at the ascending aorta(p = 0.0840). Image quality(p = 0.0176) and discomfort during injection(p = 0.7034) were comparable for all groups. General discomfort after injection of contrast media with 300 mg iodine/ml was statistically significant higher compared to 370 mg iodine/ml(p = 0.00019). Given identical iodine delivery rates of 1.3 g/s and iodine loads of 33 g, contrast media with concentrations of 300, 370 and 400 mg iodine/ml do not result in different intravascular enhancement in chest-CT. (orig.)

  19. Quantifying the effects of iodine contrast media on standardised uptake values of FDG PET/CT images: an anthropomorphic phantom study.

    Science.gov (United States)

    Abdul Razak, Hairil Rashmizal; Nordin, Abdul Jalil; Ackerly, Trevor; Van Every, Bruce; Martin, Ruth; Geso, Moshi

    2011-09-01

    This study aimed to quantify the amount of change in Standardised Uptake Values (SUVs) of PET/CT images by simulating the set-up as closely as possible to the actual patient scanning. The experiments were conducted using an anthropomorphic phantom, which contained an amount of radioactivity in the form of Fluorodeoxyglucose (FDG) in a primary plastic test tube and one litre saline bags, including the insertion of bony structures and another two test tubes containing different concentrations of iodine contrast media. Standard scanning protocols were employed for the PET/CT image acquisition. The highest absolute differences in the SUVmax and SUVmean values of the saline bags were found to be about 0.2 and 0.4, respectively. The primary test tube showed the largest change of 1.5 in both SUVs; SUV max and SUVmean. However, none of these changes were found to be statistically significant. The clinical literature also contains no evidence to suggest that the changes of this magnitude would change the final diagnosis. Based on these preliminary data, we propose that iodine contrast media can be used during the CT scan of PET/CT imaging, without significantly affecting the diagnostic quality of this integrated imaging modality.

  20. Hypersensitivity to contrast media and dyes.

    Science.gov (United States)

    Brockow, Knut; Sánchez-Borges, Mario

    2014-08-01

    This article updates current knowledge on hypersensitivity reactions to diagnostic contrast media and dyes. After application of a single iodinated radiocontrast medium (RCM), gadolinium-based contrast medium, fluorescein, or a blue dye, a hypersensitivity reaction is not a common finding; however, because of the high and still increasing frequency of those procedures, patients who have experienced severe reactions are nevertheless frequently encountered in allergy departments. Evidence on allergologic testing and management is best for iodinated RCM, limited for blue dyes, and insufficient for fluorescein. Skin tests can be helpful in the diagnosis of patients with hypersensitivity reactions to these compounds. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Prediction of presence of kidney disease in a general patient population undergoing intravenous iodinated contrast enhanced computed tomography.

    Science.gov (United States)

    Moos, Shira I; Stoker, Jaap; Nagan, Gajenthiran; de Weijert, Roderick S; van Vemde, David N H; Bipat, Shandra

    2014-06-01

    To assess which risk factors can be used to reduce superfluous estimated glomerular filtration rate (eGFR) measurements before intravenous contrast medium administration. In consecutive patients, all decreased eGFR risk factors were assessed: diabetes mellitus (DM), history of urologic/nephrologic disease (HUND), nephrotoxic medication, cardiovascular disease, hypertension, age > 60 years, anaemia, malignancy and multiple myeloma/M. Waldenström. We studied four models: (1) all risk factors, (2) DM, HUND, hypertension, age > 60 years; (3) DM, HUND, cardiovascular disease, hypertension; (4) DM, HUND, age > 75 years and congestive heart failure. For each model, association with eGFR < 60 ml/min/1.73 m(2) or eGFR < 45 ml/min/1.73 m(2) was studied. A total of 998 patients, mean age 59.94 years were included; 112 with eGFR < 60 ml/min/1.73 m(2) and 30 with eGFR < 45 ml/min/1.73 m(2). Model 1 detected 816 patients: 108 with eGFR < 60 ml/min/1.73 m(2) and all 30 with eGFR < 45 ml/min/1.73 m(2). Model 2 detected 745 patients: 108 with eGFR < 60 ml/min/1.73 m(2) and all 30 with eGFR < 45 ml/min/1.73 m(2). Model 3 detected 622 patients: 100 with eGFR < 60 ml/min/1.73 m(2) and all 30 with eGFR < 45 ml/min/1.73 m(2). Model 4 detected 440 patients: 86 with eGFR < 60 ml/min/1.73 m(2) and all 30 with eGFR < 45 ml/min/1.73 m(2). Associations were significant (p < 0.001). Model 4 is most effective, resulting in the lowest proportion of superfluous eGFR measurements while detecting all patients with eGFR < 45 ml/min/1.73 m(2) and most with eGFR < 60 ml/min/1.73 m(2). A major risk factor for contrast-induced nephropathy (CIN) is kidney disease. Risk factors are used to identify patients with pre-existent kidney disease. Evidence for risk factors to identify patients with kidney disease is limited. The number of eGFR measurements to detect kidney disease can be reduced.

  2. A sensitive multi-residue method for the determination of 35 micropollutants including pharmaceuticals, iodinated contrast media and pesticides in water.

    Science.gov (United States)

    Valls-Cantenys, Carme; Scheurer, Marco; Iglesias, Mònica; Sacher, Frank; Brauch, Heinz-Jürgen; Salvadó, Victoria

    2016-09-01

    A sensitive, multi-residue method using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed to determine a representative group of 35 analytes, including corrosion inhibitors, pesticides and pharmaceuticals such as analgesic and anti-inflammatory drugs, five iodinated contrast media, β-blockers and some of their metabolites and transformation products in water samples. Few other methods are capable of determining such a broad range of contrast media together with other analytes. We studied the parameters affecting the extraction of the target analytes, including sorbent selection and extraction conditions, their chromatographic separation (mobile phase composition and column) and detection conditions using two ionisation sources: electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI). In order to correct matrix effects, a total of 20 surrogate/internal standards were used. ESI was found to have better sensitivity than APCI. Recoveries ranging from 79 to 134 % for tap water and 66 to 144 % for surface water were obtained. Intra-day precision, calculated as relative standard deviation, was below 34 % for tap water and below 21 % for surface water, groundwater and effluent wastewater. Method quantification limits (MQL) were in the low ng L(-1) range, except for the contrast agents iomeprol, amidotrizoic acid and iohexol (22, 25.5 and 17.9 ng L(-1), respectively). Finally, the method was applied to the analysis of 56 real water samples as part of the validation procedure. All of the compounds were detected in at least some of the water samples analysed. Graphical Abstract Multi-residue method for the determination of micropollutants including pharmaceuticals, iodinated contrast media and pesticides in waters by LC-MS/MS.

  3. Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography

    International Nuclear Information System (INIS)

    Seifarth, Harald; Puesken, Michael; Wienbeck, Susanne; Wessling, Johannes; Maintz, David; Heindel, Walter; Juergens, Kai-Uwe; Kalafut, John F.

    2009-01-01

    The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s. For group 2 injection parameters were individually adjusted to patient weight, the duration of CT data acquisition, and attenuation parameters following a test bolus. In the control group (group 3) the volume of CM was adjusted to the duration of CT data acquisition and injected at 5 mL/s. Attenuation was measured in the proximal, middle, and distal right coronary artery (RCA), in the proximal and middle left anterior descending artery (LAD), and in cranial and caudal sections of both ventricles. Patient parameters, scan delay, and scan duration did not differ significantly between the groups. Mean CM volume was 82.5 mL (flow rate 5.1 mL/s) in group 2 and 73.5 mL in group 3. Attenuation in both RCA and LAD was significantly higher for group 2 vs. group 3 (RCA: 414.9(±49.9)-396.1(±52.1) HU vs. 366.0(±64.3)-341.6(±72.5) HU; LAD: 398.9(±48.6)-364.6(±44.6) HU vs. 356.3(±69.5)-323.0(±67.2) HU). For group 1 vs. group 2 only attenuation in the distal RCA differed significantly: 396.1(±52.1) vs. 370.7(±70.5) HU. Individually tailored CM injection protocols yield higher attenuation, especially in the distal segments of the coronary vessels, compared with injection protocols using fixed injection parameters. (orig.)

  4. Morphometric analysis of stab wounds by MSCT and MRI after the instillation of contrast medium.

    Science.gov (United States)

    Fais, Paolo; Cecchetto, Giovanni; Boscolo-Berto, Rafael; Toniolo, Matteo; Viel, Guido; Miotto, Diego; Montisci, Massimo; Tagliaro, Franco; Giraudo, Chiara

    2016-06-01

    To analyze the morphology and depth of stab wounds experimentally produced on human legs amputated for medical reasons using multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) after the instillation of a single contrast medium solution (CMS). For morphological analysis, MSCT and MRI scans were performed before and after the instillation of CMS into the wound cavity. Depth measurements were performed on the sagittal view only after CMS instillation. Subsequently, each wound was dissected using the layer-by-layer technique and the depth was measured by a ruler. One-way between-groups pairwise analysis of variance (ANOVA) and Bland-Altman plot analysis were used for comparing radiological and anatomical measurements. Unenhanced MSCT images did not identify the wound channels, whereas unenhanced MRI evidenced the wound cavity in 50 % of cases. After the instillation of CMS, both MSCT and MRI depicted the wound channel in all the investigated stabbings, although the morphology of the cavity was irregular and did not resemble the shape of the blade. The radiological measurements of the wounds' depth, after the application of CMS, exhibited a high level of agreement (about 95 % at Bland-Altman plot analysis) with the anatomical measurements at dissection. A similar systematic underestimation, however, has been evidenced for MSCT (average 11.4 %; 95 % CI 7-17) and MRI (average 9.6 %; 95 % CI 6-13) data after the instillation of CMS with respect to wound dissection measurements. MSCT and MRI after the instillation of CMS can be used for depicting the morphometric features of stab wounds, although depth measurements are affected by a slight systematic underestimation compared to layer-by-layer dissection.

  5. Contrast Materials

    Science.gov (United States)

    ... is mixed with water before administration liquid paste tablet When iodine-based and barium-sulfate contrast materials ... for patients with kidney failure or allergies to MRI and/or computed tomography (CT) contrast material. Microbubble ...

  6. Intravenous administration of iodinated, non-ionic, low or isoosmolar contrast media: safety aspects; Intravenoese Anwendung von jodiertem, nichtionischem, nieder- bis isoosmolarem Kontrastmittel: Sicherheitsaspekte

    Energy Technology Data Exchange (ETDEWEB)

    Metz-Schimmerl, S.; Metz, V.; Schima, W.; Herold, C. [Universitaetsklinik fuer Radiodiagnostik und Ludwig Boltzmann-Institut fuer Klinische und Experimentelle Radiologie, Wien (Austria); Domanovits, H. [Universitaetsklinik fuer Notfallmedizin Wien, Wien (Austria)

    2002-01-01

    It iss the purpose of this review to provide information about the safe use of intravenously administered, iodinated, non-ionic, low or isoosmolar contrast media for radiological examinations, how to avoid adverse events, and how to react professionally in case of an anaphylactic reaction. Methods of prophylaxis and therapy for anaphylactic and chemotoxic effects of contrast media administration as well as absolute and relative contraindications are discussed. Medico-legal considerations of contrast agent administration, informed consent of patients, and methods of risk management for undesired contrast media reactions are considered in this article. Establishment of administration standards for contrast media is of tremendous importance to standardize radiological procedures. This basic radiological documentation is part of the institutional and individual legal safety management. (orig.) [German] Ziel dieses Artikels ist es, Kenntnisse zur sicheren Anwendung von intravenoes applizierten, jodierten, nichtionischen, nieder- bis isoosmolaren Roentgen-Kontrastmitteln zu vermitteln, um bei deren Verwendung unerwuenschte Wirkungen zu vermeiden oder im Falle eines anaphylaktischen Kontrastmittelzwischenfalls rasch und effektiv zu handeln. Neben Methoden der Verhuetung und Behandlung anaphylaktischer und chemotoxischer Wirkungen der Kontrastmittelgabe werden Einschraenkungen der Anwendung bei unterschiedlichen klinischen Bildern eroertert. Rechtliche Ueberlegungen zur Kontrastmittelanwendung, das Aufklaerungsgespraech und Praeventivmassnahmen zum Risiko-Management unerwuenschter Kontrastmittelwirkungen sind beruecksichtigt. Die Festlegung von Anwendungstandards fuer Kontrastmittel dient der Normierung medizinischen Vorgehens. Eine solche radiologische Basisdokumentation ist teil der institutionellen und individuellen rechtlichen Absicherung. (orig.)

  7. Prophylaxis and treatment of side effects due to iodinated contrast media relevant to radiological practice; Radiologisch praxisrelevante Prophylaxe und Therapie von Nebenwirkungen jodhaltiger Kontrastmittel

    Energy Technology Data Exchange (ETDEWEB)

    Becker, C. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2007-09-15

    Increased utilization of iodinated contrast media may be associated with increased incidence of adverse events. The most important side effects include contrast-induced nephropathy, anaphylactoid reaction, thyrotoxicosis, and extravasation. In patients with moderate renal dysfunction, saline hydration and reduction of contrast media volume are recommended. No regime to prevent anaphylactoid reactions has yet proven to be efficient. If subclinical hyperthyroidism has been determined, prophylaxis with sodium perchlorate is advised. Contrast-induced nephropathy is commonly transient and needs to be followed over time. Mild general anaphylactoid reactions may be treated with antihistaminic drugs and corticosteroids. Furthermore the choice of the X-ray contrast media might influence the risk of any adverse effects. (orig.) [German] Durch den zunehmenden Einsatz jodhaltiger Kontrastmittel in der Radiologie steigt auch die Rate der Nebenwirkungen; zu den wichtigsten gehoeren die kontrastmittelinduzierte Nephropathie, anaphylaktoide Reaktion, thyreotoxische Krise und Extravasation. Bei Patienten mit mittelgradig eingeschraenkter Nierenfunktion wird eine Prophylaxe durch Hydrierung und Reduktion der KM-Menge empfohlen. Bei hochgradig eingeschraenkter Nierenfunktion sollte die Kontrastmittelgabe nur noch kontrolliert im interdisziplinaeren Konsens erfolgen. Eine nachgewiesen wirkungsvolle Prophylaxe anaphylaktoider Reaktionen ist bisher nicht bekannt. Bei Nachweis einer sublatenten Hyperthyreose ist die Gabe von Natriumperchlorat eine sinnvolle Gegenmassnahme. Eine kontrastmittelinduzierte Nephropathie ist meistens transient und sollte mehrfach im Verlauf kontrolliert werden. Leichte allgemeine anaphylaktoide Reaktionen koennen mit Antihistaminika und Kortikosteroiden behandelt werden. Auch die Wahl des Roentgenkontrastmittels koennte Einfluss auf das Risiko von Nebenwirkungen haben. (orig.)

  8. Iodine Deficiency

    Science.gov (United States)

    ... Fax/Phone Home » Iodine Deficiency Leer en Español Iodine Deficiency Iodine is an element that is needed ... world’s population remains at risk for iodine deficiency. Iodine Deficiency FAQs WHAT IS THE THYROID GLAND? The ...

  9. Nuclear magnetic resonance diagnosis of cerebral tumours with the use of the contrast medium gadolinium-DTPA

    International Nuclear Information System (INIS)

    Schoerner, W.; Felix, R.; Claussen, C.; Fiegler, W.; Kazner, E.; Speck, U.; Niendorf, H.P.

    1984-01-01

    This study examines the effect of the NMR contrast medium gadolinium-DTPA on image contrast in cerebral tumours. Sixteen patients with space-occupying cerebral lesions were examined on a 0.35 Tesla superconducting scanner, using a T1-weighted spinecho sequence prior to and after the intravenous application of gadolinium-DTPA. In 8 patients T2-weighted spinecho-sequences were obtained before the administration of contrast. The tomograms were evaluated visually and according to quantitative criteria. The use of gadolinium-DTPA helps to evaluate the blood-brain barrier and improves diagnosis by differentiating tumour tissue from edema and from normal brain tissue. (orig.) [de

  10. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  11. Prediction of presence of kidney disease in a general patient population undergoing intravenous iodinated contrast enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moos, Shira I.; Stoker, Jaap; Nagan, Gajenthiran; Weijert, Roderick S. de; Vemde, David N.H. van; Bipat, Shandra [Academic Medical Center, University of Amsterdam, Department of Radiology, G1-215, Amsterdam (Netherlands)

    2014-06-15

    To assess which risk factors can be used to reduce superfluous estimated glomerular filtration rate (eGFR) measurements before intravenous contrast medium administration. In consecutive patients, all decreased eGFR risk factors were assessed: diabetes mellitus (DM), history of urologic/nephrologic disease (HUND), nephrotoxic medication, cardiovascular disease, hypertension, age > 60 years, anaemia, malignancy and multiple myeloma/M. Waldenstroem. We studied four models: (1) all risk factors, (2) DM, HUND, hypertension, age > 60 years; (3) DM, HUND, cardiovascular disease, hypertension; (4) DM, HUND, age > 75 years and congestive heart failure. For each model, association with eGFR < 60 ml/min/1.73 m{sup 2} or eGFR < 45 ml/min/1.73 m{sup 2} was studied. A total of 998 patients, mean age 59.94 years were included; 112 with eGFR < 60 ml/min/1.73 m{sup 2} and 30 with eGFR < 45 ml/min/1.73 m{sup 2}. Model 1 detected 816 patients: 108 with eGFR < 60 ml/min/1.73 m{sup 2} and all 30 with eGFR < 45 ml/min/1.73 m{sup 2}. Model 2 detected 745 patients: 108 with eGFR < 60 ml/min/1.73 m{sup 2} and all 30 with eGFR < 45 ml/min/1.73 m{sup 2}. Model 3 detected 622 patients: 100 with eGFR < 60 ml/min/1.73 m{sup 2} and all 30 with eGFR < 45 ml/min/1.73 m{sup 2}. Model 4 detected 440 patients: 86 with eGFR < 60 ml/min/1.73 m{sup 2} and all 30 with eGFR < 45 ml/min/1.73 m{sup 2}. Associations were significant (p < 0.001). Model 4 is most effective, resulting in the lowest proportion of superfluous eGFR measurements while detecting all patients with eGFR < 45 ml/min/1.73 m{sup 2} and most with eGFR < 60 ml/min/1.73 m{sup 2}. (orig.)

  12. Multi-detector row helical CT of the liver. Quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT. A prospective randomized study

    International Nuclear Information System (INIS)

    Tsurusaki, Masakatsu; Sugimoto, Koji; Fujii, Masahiko; Sugimura, Kazuro

    2004-01-01

    The purpose of this study was to assess the quantitative effects of contrast material concentration on hepatic parenchymal and vascular enhancement in multiphasic computed tomography (CT), using multi-detector row helical CT. We designed a prospective randomized study to test two different concentrations of contrast material on five phasic scans of the liver. One hundred patients were randomly assigned to two groups: an iodine concentration of 300 mg/mL in group A and 370 mg/mL in group B. All patients received a fixed volume of 100 mL at a 4 mL/sec injection rate. Enhancement values for the hepatic parenchyma and aorta at three levels (upper, middle, and lower level of the liver), and values for portal and hepatic veins were statistically compared between the two groups. Hepatic parenchymal enhancement values at all levels of the liver in portal phase (PP) and equilibrium phase (EP) were significantly higher in group B than in group A (p<0.01). Aortic enhancement values at two levels of the liver (middle and lower) in early hepatic arterial phase (EAP) were significantly higher in group B than in group A (p<0.05), however, there was no significant difference between groups A and B in aortic enhancement during the delayed hepatic arterial phase (DAP). Portal and hepatic venous enhancement values in PP and EP were significantly higher in group B than in group A (p<0.01). On multiphasic dynamic CT, the use of a higher iodine concentration of contrast material results in higher hepatic parenchymal enhancement and aortic enhancement, as well as higher portal and hepatic venous enhancement. (author)

  13. The predictive value of the product of contrast medium volume and urinary albumin/creatinine ratio in contrast-induced acute kidney injury.

    Science.gov (United States)

    Wang, Chunrui; Ma, Shuai; Deng, Bo; Lu, Jianxin; Shen, Wei; Jin, Bo; Shi, Haiming; Ding, Feng

    2017-11-01

    Preexisting renal impairment and the amount of contrast media are the most important risk factors for contrast-induced acute kidney injury (CI-AKI). We aimed to investigate whether the product of contrast medium volume and urinary albumin/creatinine ratio (CMV × UACR) would be a better predictor of CI-AKI in patients undergoing nonemergency coronary interventions. This was a prospective single-center observational study, and 912 consecutive patients who were exposed to contrast media during coronary interventions were investigated prospectively. CI-AKI is defined as a 44.2 μmol/L rise in serum creatinine or a 25% increase, assessed within 48 h after administration of contrast media in the absence of other causes. Fifty patients (5.48%) developed CI-AKI. The urinary albumin/creatinine ratio (UACR) (OR = 1.002, 95% CI = 1.000-1.003, p = .012) and contrast medium volume (CMV) (OR = 1.008, 95% CI = 1.001-1.014, p = .017) were independent risk factors for the development of CI-AKI. The area under the ROC curve of CMV, UACR and CMV × UACR were 0.662 (95% CI = 0.584-0.741, p < .001), 0.761 (95% CI = 0.674-0.847, p < .001) and 0.808 (95% CI = 0.747-0.896, p < .001), respectively. The cutoff value of CMV × UACR to predict CI-AKI was 1186.2, with 80.0% sensitivity and 62.2% specificity. The product of CMV and UACR (CMV × UACR) might be a predictor of CI-AKI in patients undergoing nonemergency coronary interventions, which was superior to CMV or UACR alone.

  14. Weight-adapted iodinated contrast media administration in abdomino-pelvic CT: Can image quality be maintained?

    Science.gov (United States)

    Perrin, E; Jackson, M; Grant, R; Lloyd, C; Chinaka, F; Goh, V

    2018-02-01

    In many centres, a fixed method of contrast-media administration is used for CT regardless of patient body habitus. The aim of this trial was to assess contrast enhancement of the aorta, portal vein, liver and spleen during abdomino-pelvic CT imaging using a weight-adapted contrast media protocol compared to the current fixed dose method. Thirty-nine oncology patients, who had previously undergone CT abdomino-pelvic imaging at the institution using a fixed contrast media dose, were prospectively imaged using a weight-adapted contrast media dose (1.4 ml/kg). The two sets of images were assessed for contrast enhancement levels (HU) at locations in the liver, aorta, portal vein and spleen during portal-venous enhancement phase. The t-test was used to compare the difference in results using a non-inferiority margin of 10 HU. When the contrast dose was tailored to patient weight, contrast enhancement levels were shown to be non-inferior to the fixed dose method (liver p contrast dose reduction of 165 ml using the weight-adapted method compared to the fixed dose method, with a mean cost per patient of £6.81 and £7.19 respectively. Using a weight-adapted method of contrast media administration was shown to be non-inferior to a fixed dose method of contrast media administration. Patients weighing 76 kg, or less, received a lower contrast dose which may have associated cost savings. A weight-adapted contrast media protocol should be implemented for portal-venous phase abdomino-pelvic CT for oncology patients with adequate renal function (>70 ml/min/1.73 m 2 ). Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  15. Magnetic resonance tomography for focal lesions in the liver using the para-magnetic contrast medium gadolinium DTPA

    International Nuclear Information System (INIS)

    Hamm, B.; Roemer, T.; Felix, R.; Wolf, K.J.; Klinikum Charlottenburg, Berlin

    1986-01-01

    The use of the para-magnetic contrast medium gadolinium DTPA for magnetic resonance tomography of focal lesions in the liver was investigated in 31 patients. Two dosage schedules of the contrast medium (0.1 and 0.2 mmol/kg body weight) were used with field strengths of 0.35 and 0.5 Tesla. Using T 1 sequences, gadolinium DTPA showed increased signal intensity in the liver and in tumours, but this was significantly more marked in the tumour. On T 1 spin-echo sequences, previously iso-intense lesions became visible after administration of contrast. On the other hand, contrast-enhanced lesions were less well seen on inversion recovery sequences because of a reduction in the contrast between tumour and liver tissue. The contrast between tumour and liver tissue was not improved by gadolinium DTPA in comparison with precontrast inversion recovery sequences and T 2 spin-echo sequences. The perfusion of intra-hepatic tumours could be elucidated by magnetic resonance tomography after the administration of gadolinium DTPA. (orig.) [de

  16. Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.

    Science.gov (United States)

    Mariani, José; Guedes, Cristiano; Soares, Paulo; Zalc, Silvio; Campos, Carlos M; Lopes, Augusto C; Spadaro, André G; Perin, Marco A; Filho, Antonio Esteves; Takimura, Celso K; Ribeiro, Expedito; Kalil-Filho, Roberto; Edelman, Elazer R; Serruys, Patrick W; Lemos, Pedro A

    2014-11-01

    The aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI). To date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast. A total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months. The median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p MOZART]; NCT01947335). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Clinical observation of adverse drug reactions to non-ionic iodinated contrast media in population with underlying diseases and risk factors

    Science.gov (United States)

    Li, Xue; Liu, Heng; Zhao, Li; Liu, Junling; Cai, Li; Liu, Lei

    2017-01-01

    Objective: To determine the adverse drug reaction (ADR) profile of non-ionic iodinated contrast media in populations with underlying diseases and risk factors and to provide guidance for more safe and rational use of iodinated contrast media (ICMs) in the clinic. Methods: Data from 120,822 cases who underwent enhanced CT examination in our hospital from January 2014 to March 2016 were collected. A standardized case report form was used for data collection and analysis. Results: The incidence of ADRs was 0.4% and 0.44% in patients with and without underlying diseases, respectively (p = 0.378). Risk factor analysis revealed that patients with asthma had the highest incidence of ADRs, followed by patients with cardiac insufficiency and patients who were aged had the lowest incidence. There was a low incidence of ADRs in patients under metformin (0.36%) and β-adrenaline receptor antagonist (0.20%) medication. The incidence was the highest in patients with previous ADRs to ICMs (7.17%) and the lowest in those with a history of ICM usage but no previous reactions (0.32%). ADRs were more common in patients at high risk at a higher injection dose (≥100 ml; p < 0.01) and speed (≥5 ml s−1; p < 0.01). Conclusion: The incidence of ADRs was extremely low in patients regardless of underlying diseases. Some high-risk factors have certain correlations with the occurrence of ADRs. Particular attention should be given to patients at high risk when performing enhanced CT examination. Advances in knowledge: The correlation between various risk factors and underlying diseases and ADRs was comprehensively analyzed in a large-scale population. PMID:27928926

  18. Case with high cervical intramedullary hemangioblastoma associated with arteriovenous fistula. CT with simultaneous intravenous and intrathecal injection of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takao; Shoji, Shin-ichi; Yanagisawa, Nobuo; Tada, Tsuyoshi; Kobayashi, Naoki

    1988-02-01

    A 34-year-old woman complained of right hemiparesis and pain in the right hand. Routine X-ray of the cervical portion failed to reveal abnormal findings. CT with intravenous contrast medium showed a large high-density mass in the spinal canal at the level of C2. Right vertebral angiography showed a hypervascular mass. With simultaneous intravenous and intrathecal injections of contrast medium, the tumor was shown as a moderately high-density area and the parenchyma of cord as a thin low-density area surrounding the tumor stain on CT. These CT appearances led to the final diagnosis of high cervical intramedullary hemangioblastoma associated with arteriovenous fistulae. Pathological findings are typical of hemangioblastoma. The usefulness of CT in detecting the localization of hypervascular spinal cord lesions is stressed. (Namekawa, K.).

  19. Screening for impaired renal function in outpatients before iodinated contrast injection: Comparing the Choyke questionnaire with a rapid point-of-care-test

    Energy Technology Data Exchange (ETDEWEB)

    Too, C.W., E-mail: toochowwei@gmail.com [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Ng, W.Y., E-mail: ng.wai.yoong@sgh.com.sg [Department of Pathology, Singapore General Hospital, 20 College Road, Academia, Singapore 169856 (Singapore); Tan, C.C., E-mail: tan.chin.chong@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Mahmood, M.I., E-mail: muhd.illyyas.mahmood@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Tay, K.H., E-mail: tay.kiang.hiong@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)

    2015-07-15

    Highlights: • Iodinated intravenous contrast carries a low risk of contrast induced nephropathy (CIN). • Patients with eGFR less than 45 mL/min/1.73 m{sup 2} are particularly at risk for CIN. • The Choyke questionnaire is used to screen for impaired renal function in outpatients. • Choyke questionnaire is a good screening tool for eGFR less than 45 mL/min/1.73 m{sup 2}. • Point of care test (POCT) for serum creatinine can reduce waiting time. - Abstract: Rationale and purpose: To determine the usefulness of the Choyke questionnaire with a creatinine point-of-care test (POCT) to detect impaired renal function amongst outpatients receiving intravenous iodinated contrast in a tertiary centre. Materials and methods: Between July and December 2012, 1361 outpatients had their serum creatinine determined by POCT and answered the Chokye questionnaire just before their examination. Results: Four hundred and eighty (35.2%) patients had at least one ‘Yes’ response. Forty-four patients (3.2%) had estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m{sup 2} and 14 patients (1.0%) have eGFR <45 mL/min/1.73 m{sup 2}. Sensitivity, specificity, positive predictive value and negative predictive value of the Choyke criteria in detecting patients with eGFR <60 mL/min/1.73 m{sup 2} are respectively: 65.9%, 65.8%, 6.0% and 98.3% and to detect eGFR <45 mL/min/1.73 m{sup 2}: 92.9%, 65.3%, 2.7% and 99.9%. Only ‘Yes’ responses to ‘Have you ever been told you have renal problems?’ and ‘Do you have diabetes mellitus?’ were statistically significant in predicting eGFR <45 mL/min/1.73 m{sup 2}, with odds ratio 98.7 and 4.4 respectively. Conclusion: The Choyke questionnaire has excellent sensitivity and moderate-to-good specificity in detecting patients with <45 mL/min/1.73 m{sup 2}, below this level it has been shown that risk of contrast induced nephropathy increases significantly, making it an effective screening tool. Also the use of POCT can potentially

  20. Acute Adverse Reactions to Nonionic Iodinated Contrast Media for CT: Prospective Randomized Evaluation of the Effects of Dehydration, Oral Rehydration, and Patient Risk Factors.

    Science.gov (United States)

    Motosugi, Utaroh; Ichikawa, Tomoaki; Sano, Katsuhiro; Onishi, Hiroshi

    2016-11-01

    The objective of our study was to determine the effects of dehydration and oral rehydration on the incidence of acute adverse reactions to iodinated contrast media administered during abdominal and pelvic CT in outpatients. For our prospective randomized study performed at a single institution, adult outpatients undergoing contrast-enhanced abdominal CT were randomly divided into a rehydration group (n = 2244 patients [1379 men and 865 women]; mean age, 65.2 years; age range, 18-90 years) and a control group (n = 3715 [2112 male patients and 1603 female patients]; mean age, 65.8 years; age range, 17-96 years), which included an age- and sex-matched subgroup (adjusted control group, n = 2244). The rehydration group received an oral rehydration solution (500 mL of liquid in which osmotic pressure is adjusted to enhance gastrointestinal absorption) before abdominal and pelvic CT. Patients were also divided into subclinically dehydrated (n = 997) and hydrated (n = 4962) groups according to their answers to a questionnaire that they completed before the CT examination. The patients were interviewed about contrast-induced adverse reactions before they left the CT room, and the reactions were categorized as allergiclike or physiologic. The incidence of reactions was compared between the rehydration and control groups and between the subclinical dehydration and hydrated groups. The rehydration and control groups were compared with an unpaired t test or a chi-square or Fisher test. The overall incidence of an acute adverse reaction was 4.3% (254/5959); the acute adverse reactions included 136 allergiclike and 118 physiologic reactions. Fourteen allergiclike and nine physiologic reactions were moderate grade, and none was severe. There was no significant difference between the rehydration group and adjusted control group in the overall incidence of adverse reactions (99/2244 [4.4%] vs 100/2244 [4.5%], respectively; p = 0.9422) or between the subclinically dehydrated group

  1. Screening for impaired renal function in outpatients before iodinated contrast injection: Comparing the Choyke questionnaire with a rapid point-of-care-test

    International Nuclear Information System (INIS)

    Too, C.W.; Ng, W.Y.; Tan, C.C.; Mahmood, M.I.; Tay, K.H.

    2015-01-01

    Highlights: • Iodinated intravenous contrast carries a low risk of contrast induced nephropathy (CIN). • Patients with eGFR less than 45 mL/min/1.73 m 2 are particularly at risk for CIN. • The Choyke questionnaire is used to screen for impaired renal function in outpatients. • Choyke questionnaire is a good screening tool for eGFR less than 45 mL/min/1.73 m 2 . • Point of care test (POCT) for serum creatinine can reduce waiting time. - Abstract: Rationale and purpose: To determine the usefulness of the Choyke questionnaire with a creatinine point-of-care test (POCT) to detect impaired renal function amongst outpatients receiving intravenous iodinated contrast in a tertiary centre. Materials and methods: Between July and December 2012, 1361 outpatients had their serum creatinine determined by POCT and answered the Chokye questionnaire just before their examination. Results: Four hundred and eighty (35.2%) patients had at least one ‘Yes’ response. Forty-four patients (3.2%) had estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m 2 and 14 patients (1.0%) have eGFR <45 mL/min/1.73 m 2 . Sensitivity, specificity, positive predictive value and negative predictive value of the Choyke criteria in detecting patients with eGFR <60 mL/min/1.73 m 2 are respectively: 65.9%, 65.8%, 6.0% and 98.3% and to detect eGFR <45 mL/min/1.73 m 2 : 92.9%, 65.3%, 2.7% and 99.9%. Only ‘Yes’ responses to ‘Have you ever been told you have renal problems?’ and ‘Do you have diabetes mellitus?’ were statistically significant in predicting eGFR <45 mL/min/1.73 m 2 , with odds ratio 98.7 and 4.4 respectively. Conclusion: The Choyke questionnaire has excellent sensitivity and moderate-to-good specificity in detecting patients with <45 mL/min/1.73 m 2 , below this level it has been shown that risk of contrast induced nephropathy increases significantly, making it an effective screening tool. Also the use of POCT can potentially reduce waiting time

  2. High-pitch coronary CT angiography at 70 kVp adopting a protocol of low injection speed and low volume of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Ruiqi; Liu, Xiao Fei; Zhao, Yu; Zhang, Liang [Dept. of Radiology, The First Affiliated Hospital of China Medical University, Shenyang (China); Tong, Jia Jie [Dept. of Radiology, Hebei General Hospital, Shijiazhuang(China)

    2017-09-15

    To evaluate the feasibility and image quality (IQ) of prospectively high-pitch coronary CT angiography (CCTA) with low contrast medium injection rate at 70 kVp. One hundred and four patients with suspected coronary artery disease (body mass index < 26 kg/m{sup 2}, sinus rhythm and heart rate < 70 beats/min) were prospectively enrolled and randomly divided into two groups. In group A and group B, 28 mL and 40 mL of 370 mgI/mL iodinated contrast media was administrated at a flow rate of 3.5 and 5 mL/s, respectively. CT values, noise, signal-to-noise ratio, contrast-to-noise ratio (CNR) of the proximal segments of coronary arteries and subjective IQ were evaluated. The CT values and noise in group A were significantly lower than those in group B (434–485 Hounsfield units [HU] vs. 772–851 HU, all p < 0.001; 17.8–22.3 vs. 23.3–26.4, all p < 0.005). The CNRs of the right coronary artery and left main artery showed no statistical difference between the two groups (42.1 ± 13.8 vs. 36.8 ± 16.0, p = 0.074; 38.7 ± 10.6 vs. 38.1 ± 17.0, p = 0.819). No statistical difference was observed between the two groups in IQ scores (3.04 ± 0.75 vs. 3.0 ± 0.79, p = 0.526) and diagnostic ratio (96.1% [50/52] vs. 94.2% [49/52], p = 0.647). Prospective high-pitch CCTA at 70 kVp with 28 mL of contrast media and injection rate of 3.5 mL/s could provide diagnostic IQ for normal-weight patients with heart rate of < 70 beats/min.

  3. Estimation of shear velocity contrast for dipping or anisotropic medium from transmitted Ps amplitude variation with ray-parameter

    Science.gov (United States)

    Kumar, Prakash

    2015-12-01

    Amplitude versus offset analysis of P to P reflection is often used in exploration seismology for hydrocarbon exploration. In the present work, the feasibility to estimate crustal velocity structure from transmitted P to S wave amplitude variation with ray-parameter has been investigated separately for dipping layer and anisotropy medium. First, for horizontal and isotropic medium, the approximation of P-to-s conversion is used that is expressed as a linear form in terms of slowness. Next, the intercept of the linear regression has been used to estimate the shear wave velocity contrast (δβ) across an interface. The formulation holds good for isotropic and horizontal layer medium. Application of such formula to anisotropic medium or dipping layer data may lead to erroneous estimation of δβ. In order to overcome this problem, a method has been proposed to compensate the SV-amplitude using shifted version of SH-amplitude, and subsequently transforming SV amplitudes equivalent to that from isotropic or horizontal layer medium as the case may be. Once this transformation has been done, δβ can be estimated using isotropic horizontal layer formula. The shifts required in SH for the compensation are π/2 and π/4 for dipping layer and anisotropic medium, respectively. The effectiveness of the approach has been reported using various synthetic data sets. The methodology is also tested on real data from HI-CLIMB network in Himalaya, where the presence of dipping Moho has already been reported. The result reveals that the average shear wave velocity contrast across the Moho is larger towards the Indian side compared to the higher Himalayan and Tibetan regions.

  4. Long-term results with a nonionic contrast medium - a clinical experience report

    International Nuclear Information System (INIS)

    Hruby, W.; Stellamor, K.

    1987-01-01

    Between January 1982 and May 1986 more than 50 000 patients were examined radioligically with water-soluble (ionic and nonionic) contrast media at the Department of Radiology Rudolfstiftung, Vienna. 1983 only 2,2% of the contrast agents used were nonionic, in 1985 the share had increased to 53,3%. During this period the rate of drug-related side effects (DRSE) decreased from 6,9% (1983) to 3,3% (1985). From 1983 to 1985 DRSE were observed with 1952 patients after administration of ionic agents, whereas after application of nonionic media adverse reactions occurred in only 6 cases, so that DRSE rates of 6,98% respectively 0,07% resulted for ionic respectively nonionic contrast media. These results are discussed with regard to the physicochemical properties and physiological actions of ionic and nonionic contrast agents. (orig.) [de

  5. Transient global amnesia following cerebral angiography with non-ionic contrast medium

    International Nuclear Information System (INIS)

    Schamschula, R.G.; Soo, M.Y.S.

    1994-01-01

    Transit global amnesia (TGA) is an uncommon syndrome of recent memory deficit and inability to learn new data, usually resolving within 24 hours. Two cases following use of non-ionic contrast media in cerebral angiography are presented. The neuroanatomy of memory is reviewed. Possible aetiologies of TGA in relation to cerebral angiography include ischemia (embolic, arterial spasm), epilepsy that may be primary or tumour-related and direct toxic effects of contrast media. 19 refs., 1 fig

  6. Iodine volatility

    International Nuclear Information System (INIS)

    Beahm, E.C.; Shockley, W.E.

    1984-01-01

    The ultimate aim of this program is to couple experimental aqueous iodine volatilities to a fission product release model. Iodine partition coefficients, for inorganic iodine, have been measured during hydrolysis and radiolysis. The hydrolysis experiments have illustrated the importance of reaction time on iodine volatility. However, radiolysis effects can override hydrolysis in determining iodine volatility. In addition, silver metal in radiolysis samples can react to form silver iodide accompanied by a decrease in iodine volatility. Experimental data are now being coupled to an iodine transport and release model that was developed in the Federal Republic of Germany

  7. Are there any differences in acute adverse reactions among five low-osmolar non-ionic iodinated contrast media?

    Energy Technology Data Exchange (ETDEWEB)

    Gomi, Tatsuya; Nagamoto, Masashi; Hasegawa, Makoto; Katoh, Asako; Sugiyama, Miki; Murata, Nozomu; Kunihiro, Toshiyuki; Kohda, Ehiichi [Toho University Ohashi Medical Centre, Department of Radiology, Tokyo (Japan)

    2010-07-15

    The differences regarding adverse reactions in different low-osmolar non-ionic contrast media had not been investigated previously. Thus, the aims of this study were to identify differences in the incidence of adverse reactions in five different low-osmolar non-ionic contrast media. We prospectively recorded all adverse events associated with five different low-osmolar non-ionic contrast media used in 8,931 consecutive patients for CT. Patients were randomly assigned to five groups: iomeprol 300 mgI/ml, iopamidol 300 mgI/ml, iohexol 300 mgI/ml, iopromide 300 mgI/ml and ioversol 320 mgI/ml. Adverse events were observed in 241 patients (2.7%). The incidence of acute adverse reactions was significantly higher in the following groups: (1) iomeprol (3.9%) and iopromide (3.5%) groups, (2) patients aged 59 years or less (4.5%) compared with those aged 60 years or over (1.9%), (3) the first period (3.5%) compared with the late period (2.3%), (4) those with a past history of adverse reactions to contrast media (11.2%), and (5) patients receiving contrast media for the first time (3.3%) compared with those had received it previously (2.0%). The incidence of acute adverse reactions may be reduced in younger patients by using iopamidol, iohexol and ioversol. (orig.)

  8. Are there any differences in acute adverse reactions among five low-osmolar non-ionic iodinated contrast media?

    International Nuclear Information System (INIS)

    Gomi, Tatsuya; Nagamoto, Masashi; Hasegawa, Makoto; Katoh, Asako; Sugiyama, Miki; Murata, Nozomu; Kunihiro, Toshiyuki; Kohda, Ehiichi

    2010-01-01

    The differences regarding adverse reactions in different low-osmolar non-ionic contrast media had not been investigated previously. Thus, the aims of this study were to identify differences in the incidence of adverse reactions in five different low-osmolar non-ionic contrast media. We prospectively recorded all adverse events associated with five different low-osmolar non-ionic contrast media used in 8,931 consecutive patients for CT. Patients were randomly assigned to five groups: iomeprol 300 mgI/ml, iopamidol 300 mgI/ml, iohexol 300 mgI/ml, iopromide 300 mgI/ml and ioversol 320 mgI/ml. Adverse events were observed in 241 patients (2.7%). The incidence of acute adverse reactions was significantly higher in the following groups: (1) iomeprol (3.9%) and iopromide (3.5%) groups, (2) patients aged 59 years or less (4.5%) compared with those aged 60 years or over (1.9%), (3) the first period (3.5%) compared with the late period (2.3%), (4) those with a past history of adverse reactions to contrast media (11.2%), and (5) patients receiving contrast media for the first time (3.3%) compared with those had received it previously (2.0%). The incidence of acute adverse reactions may be reduced in younger patients by using iopamidol, iohexol and ioversol. (orig.)

  9. Effect of Saline Pushing after Contrast Material Injection in Abdominal Multidetector Computed Tomography with the Use of Different Iodine Concentrations

    International Nuclear Information System (INIS)

    Tatsugami, F.; Matsuki, M.; Kani, H.; Tanikake, M.; Miyao, M.; Yoshikawa, S.; Narabayashi, I.

    2006-01-01

    Purpose: To investigate whether saline pushing after contrast material improves hepatic vascular and parenchymal enhancement, and to determine whether this technique permits decreased contrast material concentration. Material and Methods: 120 patients who underwent hepatic multidetector computed tomography were divided randomly into four groups (Groups A-D): receiving 100 ml of contrast material (300 mgI/ml) only (A) or with 50 ml of saline solution (B); or 100 ml of contrast material (350 mgI/ml) only (C) or with 50 ml of saline solution (D). Computed tomography (CT) values of the aorta in the arterial phase, the portal vein in the portal venous inflow phase, and the liver in the hepatic phase were measured. Visualization of the hepatic artery and the portal vein by 3D CT angiography was evaluated as well. Results: Although the enhancement values of the aorta were not improved significantly with saline pushing, they continued at a high level to the latter slices with saline pushing. The enhancement value of the portal vein increased significantly and CT portography was improved with saline pushing. The enhancement value of the liver was not improved significantly using saline pushing. In a comparison between groups B and C, the enhancement values of the aorta and portal vein and the visualization of CT arteriography and portography were not statistically different. Conclusion: The saline pushing technique can contribute to a decrease in contrast material concentration for 3D CT arteriography and portography

  10. The iodine reactivity

    International Nuclear Information System (INIS)

    2003-01-01

    The iodine is an important element because it has long life isotopes (such as iodine 129) and a great mobility in natural media. Iodine presents a complex chemistry because of its volatility and its strong redox reactivity. The S.E.C.R. works to better understand the reactivity of this element in different natural, industrial or biological environments. It plays a part in thermochemical sites as a possible way of hydrogen formation. This seminar gives some aspects relative to the chemical reactivity of iodine, since its thermochemistry in the I/S cycles to produce hydrogen to its reactivity in the natural medium and its potential radiological impact. This document includes 4 presentations transparencies) dealing with: the 129 I cycle rejected in the low radioactive gaseous and liquid effluents of the La Hague reprocessing plant (C. Frechou); a bibliographic review of iodine retention in soils (F. Bazer-Bachi); the hydrogen production and the iodine/sulfur thermochemical cycle (role of iodine in the process); and the direct characterization by electro-spray ionization mass spectroscopy of iodine fixation by fulvic acids (P. Reiller, B. Amekraz, C. Moulin, V. Moulin)

  11. Does the MRI or MRI contrast medium gadopentetate dimeglumine change the oxidant and antioxidant status in humans?

    Energy Technology Data Exchange (ETDEWEB)

    Olmaz, Refik; Oguz, Ebru Gok; Kiykim, Ahmet; Turgutalp, Kenan [Dept. of Internal Medicine, Div. of Nephrology, School of Medicine, Mersin Univ., Mersin (Turkey)], e-mail: k.turgutalp@hotmail.com; Horoz, M. [Dept. of Internal Medicine, Div. of Nephrology, School of Medicine, Harran Univ., Sanliurfa (Turkey); Ozhan, Onur [Dept. of Internal Medicine, Div. of Endocrinology and Metabolism, School of Medicine, Mersin Univ., Mersin (Turkey); Muslu, Necati [Dept. of Biochemistry, School of Medicine, Mersin Univ., Mersin (Turkey); Sungur, Mehmet [Dept. of Biostatistics, School of Medicine, Mersin Univ., Mersin (Turkey)

    2013-02-15

    Background: It has become evident that gadolinium-based contrast agents (GBCA) may have nephrotoxic potential. Oxidative stress is one of the most important pathways in the pathogenesis of iodinated contrast-induced nephropathy. Purpose: To investigate the effects of static magnetic fields and gadopentetate dimeglumine (Magnevist) on oxidant/antioxidant status via measurement of total antioxidant capacity (TAC), total oxidant status (TOS), and serum malondialdehide (MDA). Material and Methods: Two age- and sex-matched groups of patients not under oxidative stress conditions that underwent magnetic resonance imaging (MRI) were recruited to this study. While contrast-enhanced (Magnevist, 0.2 mmol/kg) MRI was performed in group 1, MRI without GBCA was performed in group 2. Fasting blood glucose, C-reactive protein, serum creatinine, liver enzymes, uric acid, and lipid parameters were examined in all patients. Peripheral venous blood samples in order to determine TAC, TOS, and MDA were collected before and 6, 24, and 72 h after the MRI procedures. The TOS:TAC ratio was used as the oxidative stress index (OSI). Patients were followed up to 72 h. Results: There were no significant changes in serum TAC, TOS, and MDA levels ({Delta}{sub s}erum{sub T}AC, {Delta}{sub s}erum{sub T}OS, and {Delta}{sub M}DA) in either group 6, 24, or 72 h after the procedures (P > 0.05). Furthermore, OSI did not change after the procedures in either group (P > 0.05). Conclusion: Magnetic field and gadopentetate dimeglumine (Magnevist) do not change the oxidant or antioxidant status at a dose of 0.2 mmol/kg.

  12. Does the MRI or MRI contrast medium gadopentetate dimeglumine change the oxidant and antioxidant status in humans?

    International Nuclear Information System (INIS)

    Olmaz, Refik; Oguz, Ebru Gok; Kiykim, Ahmet; Turgutalp, Kenan; Horoz, M.; Ozhan, Onur; Muslu, Necati; Sungur, Mehmet

    2013-01-01

    Background: It has become evident that gadolinium-based contrast agents (GBCA) may have nephrotoxic potential. Oxidative stress is one of the most important pathways in the pathogenesis of iodinated contrast-induced nephropathy. Purpose: To investigate the effects of static magnetic fields and gadopentetate dimeglumine (Magnevist) on oxidant/antioxidant status via measurement of total antioxidant capacity (TAC), total oxidant status (TOS), and serum malondialdehide (MDA). Material and Methods: Two age- and sex-matched groups of patients not under oxidative stress conditions that underwent magnetic resonance imaging (MRI) were recruited to this study. While contrast-enhanced (Magnevist, 0.2 mmol/kg) MRI was performed in group 1, MRI without GBCA was performed in group 2. Fasting blood glucose, C-reactive protein, serum creatinine, liver enzymes, uric acid, and lipid parameters were examined in all patients. Peripheral venous blood samples in order to determine TAC, TOS, and MDA were collected before and 6, 24, and 72 h after the MRI procedures. The TOS:TAC ratio was used as the oxidative stress index (OSI). Patients were followed up to 72 h. Results: There were no significant changes in serum TAC, TOS, and MDA levels (Δ s erum T AC, Δ s erum T OS, and Δ M DA) in either group 6, 24, or 72 h after the procedures (P > 0.05). Furthermore, OSI did not change after the procedures in either group (P > 0.05). Conclusion: Magnetic field and gadopentetate dimeglumine (Magnevist) do not change the oxidant or antioxidant status at a dose of 0.2 mmol/kg

  13. Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: a meta-analysis

    NARCIS (Netherlands)

    Moos, Shira I.; van Vemde, David N. H.; Stoker, Jaap; Bipat, Shandra

    2013-01-01

    To summarize the incidence of contrast-induced nephropathy (CIN) and associations between CIN incidence and risk factors in patients undergoing intravenous contrast-enhanced computed tomography (CECT) with low- or iso-osmolar iodinated contrast medium. This review is performed in accordance with the

  14. Gadolinium-DTPA as an oral contrast medium for MR tomography of the abdomen

    International Nuclear Information System (INIS)

    Krahe, T.; Doelken, W.; Lackner, K.; Houselog, M.

    1990-01-01

    150 MR examinations of the upper abdomen were carried out after the oral administration of 5 ml/kg body weight of a gadolinium DTPA formulation (1.0 mmol/l, 15 g/l manitol), with reference to the delineation of the pancreas, the liver and intra-abdominal fat. For comparison, 100 MR examinations without oral opacification of the G.I. tract were evaluated. Contrast administration resulted in a signal-intensive demonstration of the G.I tract for all measurement sequences. The intraluminal contrast improved the distinction between normal and abnormal structures, T 1 and T 2 sequences and the demonstration of fat on T 2 -weighted series. T 1 -weighted series showed the best diagnostic results. In 25% there was meteorism and diarrhoea within 24 hours of the administration of the oral contrast. (orig.) [de

  15. An evaluation of ultravist - a contrast medium by Schering in angiography

    International Nuclear Information System (INIS)

    Twarkowski, P.; Woynarowski, M.

    1993-01-01

    An angiography with ''uropolina'' (Polfa), ''hexabrix'' (Byk) and ''ultravist'' (Schering) was performed in 30 patients with various vascular disorders. It has appeared, that low-osmolality contrast media (''hexabrix'') and nonionic ones (''ultravist'') less frequently caused the complications than ''uropolina'', widely used by us. (author)

  16. Studies on the usefulness of negative contrast medium for CT-fatty emulsion-in diseases of the gastrointestinal tract

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Tsuneo; Kameda, Kyoko; Tanaka, Koji; Nishimura, Shigeru; Higashide, Toshiaki [Osaka Police Hospital (Japan)

    1983-09-01

    Investigation was made on the usefulness of negative contrast medium for CT-fatty emulsion-, which is applicable to the whole area of the gastrointestinal tract, in diagnoses of diseases of the stomach, pancreas, colon and the organs adjacent to the three. After the administration of the drug, CT was performed and the thickness of the walls were measured for the normal upper gastrointestinal tract in 50 patients and for the normal colon in 25. The normal gastric walls did not exceed 5 mm and the walls of the colon measured about 2.1 mm. Gastric tumors were projected at 80.4%. Especially, the drug was useful for the early diagnosis of schirrus. The pancreas was more clearly projected in 88.4% of the patients. The reconstruction method using the present drug was useful for the investigation of the relationship between the two organs, the stomach and the duodenum, and the pancreas. When CT was performed on a patient laying this right side on the bed, invasion of pancreatic cancer and gastric antrum cancer into the circumferntial organs could be diagnosed. The drug was useful for the identification of tumors in the colon and intrapelvic lesions. The medium was also given to four patients with colitis ulcerosa and the obtained findings on the wall features were same as those obtained by barium enema. The present drug was little associated with side effects and is considered to be an excellent negative contrast medium for all the gastrointestinal tracts.

  17. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  18. Comparative assessment of image quality for coronary CT angiography with iobitridol and two contrast agents with higher iodine concentrations: iopromide and iomeprol. A multicentre randomized double-blind trial

    Energy Technology Data Exchange (ETDEWEB)

    Achenbach, Stephan [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Department of Cardiology, Erlangen (Germany); Paul, Jean-Francois [Centre Chirurgical Marie Lannelongue, Department of Radiology, Le Plessis Robinson (France); Laurent, Francois [University of Bordeaux, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux (France); CHU de Bordeaux, Service d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Becker, Hans-Christoph [University Hospital Grosshadern, Department of Clinical Radiology, Munich (Germany); Rengo, Marco [Sapienza - University of Rome, ICOT Hospital, Department of Radiological Sciences, Oncology and Pathology, Latina (Italy); Caudron, Jerome [University Hospital of Rouen, Department of Radiology, Rouen (France); Leschka, Sebastian [Saint Gallen Hospital, Department of Radiology, Saint Gallen (Switzerland); Vignaux, Olivier [Cochin Hospital, Department of Radiology, Paris (France); Knobloch, Gesine [La Charite, Department of Radiology, Berlin (Germany); Benea, Giorgio [Ospedale del Delta, Ferrara (Italy); Schlosser, Thomas [Elisabeth-Krankenhaus Hospital, Essen (Germany); Andreu, Jordi [Hospital Vall d' Hebron, Barcelona (Spain); Cabeza, Beatriz [Hospital Clinico San Carlos, Madrid (Spain); Jacquier, Alexis [La Timone Adult Hospital, Department of Radiology, Marseille (France); Souto, Miguel [Complejo Hospitalario Universitario, Santiago de Compostela (Spain); Revel, Didier [Louis Pradel Hospital, Department of Radiology, Lyon (France); Qanadli, Salah Dine [University of Lausanne, Department of Radiology, Lausanne (Switzerland); Cademartiri, Filippo [Giovanni XXIII Hospital, Department of Radiology, Monastier di Treviso (Italy); Collaboration: X-ACT Study Group

    2017-02-15

    To demonstrate non-inferiority of iobitridol 350 for coronary CT angiography (CTA) compared to higher iodine content contrast media regarding rate of patients evaluable for the presence of coronary artery stenoses. In this multicentre trial, 452 patients were randomized to receive iobitridol 350, iopromide 370 or iomeprol 400 and underwent coronary CTA using CT systems with 64-detector rows or more. Two core lab readers assessed 18 coronary segments per patient regarding image quality (score 0 = non diagnostic to 4 = excellent quality), vascular attenuation, signal and contrast to noise ratio (SNR, CNR). Patients were considered evaluable if no segment had a score of 0. Per-patient, the rate of fully evaluable CT scans was 92.1, 95.4 and 94.6 % for iobitridol, iopromide and iomeprol, respectively. Non-inferiority of iobitridol over the best comparator was demonstrated with a 95 % CI of the difference of [-8.8 to 2.1], with a pre-specified non-inferiority margin of -10 %. Although average attenuation increased with higher iodine concentrations, average SNR and CNR did not differ between groups. With current CT technology, iobitridol 350 mg iodine/ml is not inferior to contrast media with higher iodine concentrations in terms of image quality for coronary stenosis assessment. (orig.)

  19. Contrasting medium and genre on Wikipedia to open up the dominating definition and classification of geoengineering

    OpenAIRE

    Markusson , Nils; Venturini , Tommaso; Laniado , David; Kaltenbrunner , Andreas

    2016-01-01

    International audience; Geoengineering is typically defined as a techno-scientific response to climate change that differs from mitigation and adaptation, and that includes diverse individual technologies, which can be classified as either solar radiation management or carbon dioxide removal. We analyse the representation of geoengineering on Wikipedia as a way of opening up this dominating, if contested, model for further debate. We achieve this by contrasting the dominating model as present...

  20. Indirect MR venography: contrast medium protocols, postprocessing and combination in diagnosing pulmonary emboli with MRI

    International Nuclear Information System (INIS)

    Kluge, A.; Bachmann, G.; Rominger, M.; Schoenburg, M.

    2004-01-01

    Purpose: Integration of MR venography in a comprehensive MR imaging protocol in patients with suspected pulmonary embolism (PE) and evaluation of contrast media dosage, timing and postprocessing for diagnostic accuracy. Materials and Methods: Fortyeight consecutive inpatients with suspected PE or deep vein thrombosis were examined by MR venography according to one of the following protocols: protocol I: MR venography only, 0.25 mmol/kg bodyweight (BW) Gadopentate dimeglumine(Gd-DTPA) as single dose, bolus timing; protocol II: MR angiography of pulmonary arteries with a cumulative dosage of 0.25 mmol/kg contrast media, modification of coil setting for MR venography without further contrast media application; protocol III: as protocol II but with 0.125 mmol/kg BW, followed by MR venography. Signal-to-noise ratio, contrast-to-noise ratio, number of definable vascular segments and image quality were evaluated. The results were compared to conventional bilateral venography. Results: All MR venography examinations were of diagnostic quality and the examination time was below 10 min. MR venography could be performed in all 48 patients comparted to 43 of 48 patients for conventional venography. Significantly more superficial and deep veins of the leg could be visualized by MR venography (94% compared to 83% for conventional venography). Sensitivity and specificity were 100% and 92%, respectively. Quality differed significantly between 0.125 mmol/kg (protocol III) and 0.25 mmol/kg Gd-DTPA (protocols I and II) while timing did not influence quality (protocol I vs. II). (orig.) [de

  1. Rapid MR measurements of contrast medium dilution kinetics (gadolinium-DTPA) in a flow phantom

    International Nuclear Information System (INIS)

    Boeck, J.C.; Sander, B.; Frank, J.; Schoerner, W.

    1991-01-01

    We studied first-pass MRI-contrast dilution to compute flow and volume of distribution in a realistic flow phantom. Pulsatile flow was provided by a one-chamber artificial heart. Physiological stroke volume, rate, pressure, and flow were adjustable. An elastic tube with dimensions similar to that of the human aorta was imaged at a rate of 2.4 Hz. After contrast injection, an initial increase in signal intensity was followed by a decrease. Signal-intensity-time plots demonstrated slightly skewed curves as expected from dispersion theory. After calibration at different gadolinium-DTPA concentrations, signal intensities were converted into true gadolinium concentrations, and flow was calculated from the concentration-time curves. Flow was varied between 2.5 and 10.0 l/min and a significant correlation was found between the MRI-estimate and true flow. Volume of distribution between injection and detection site was reliably estimated. This study demonstrates rapid 2-D imaging of a paramagnetic contrast bolus in a realistic flow phantom. Reliable estimates of flow and volume are obtained. (orig.) [de

  2. Attenuation changes of the normal and ischemic canine kidney. Dynamic CT scanning after intravenous contrast medium bolus

    Energy Technology Data Exchange (ETDEWEB)

    Jaschke, W.; Lipton, M.J.; Boyd, D.P.; Cann, C.; Strauss, L.; Sievers, R.S.

    The potential of CT scanning to explore total and regional renal blood flow was evaluated in a dog model with unilateral renal artery stenosis (n=7, reduction of renal blood flow: 32-75% of base line flow). Attenuation versus time curves were generated for the renal cortex and medulla, as well as for the aorta and renal vein. A fast CT scanner was used which allowed for up to 24 scans/minute at the same level (slice thickness: 10 mm). A total of 10 ml contrast medim was injected into a peripheral vein for each scan series taken. During baseline conditions, the curve of the renal cortex and medulla demonstrated 2 peaks. The first peak was mainly related to early vascular enhancement, whereas the second peak corresponded mainly to the appearance of contrast medium in the distal convolutes and collecting ducts. Ischemia of the kidney resulted in a reduction of the first peak and a flattening of the leading edge slope. Transport of contrast medium through the extravascular compartments of the kidney was delayed during ischemia. Relative renal blood flow was obtained from the CT data by dividing peak enhancement by rise-time as assessed from the cortical curve. All measurements were related to baseline flow and validated by flow measurements using radioactive labeled microspheres (n=5). Correlation was found to be r=0.97. (orig.).

  3. Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Qi, Li; Tang, Chun Xiang; Zhou, Chang Sheng; Ji, Xue Man; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Wang, Jing [Medical School of Nanjing University, Department of Cardiology, Jinling Hospital, Nanjing, Jiangsu (China); Spearman, James V.; De Cecco, Carlo Nicola; Meinel, Felix G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2014-07-15

    To evaluate the feasibility, image quality and radiation dose of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) with 30 mL contrast agent at 70 kVp. Fifty-eight patients with suspected coronary artery disease, a body mass index (BMI) of less than 25 kg/m{sup 2}, sinus rhythm and a heart rate (HR) of less than 70 beats per minute (bpm) were prospectively enrolled in this study. Thirty mL of 370 mg I/mL iodinated contrast agent was administrated at a flow rate of 5 mL/s. All patients underwent prospectively ECG-triggered high-pitch CCTA on a second-generation dual-source CT system at 70 kVp using automated tube current modulation. Fifty-six patients (96.6 %) had diagnostic CCTA images and two patients (3.4 %) had one vessel with poor image quality each rated as non-diagnostic. No significant effects of HR, HR variability and BMI on CCTA image quality were observed (all P > 0.05). Effective dose was 0.17 ± 0.02 mSv and the size-specific dose estimate was 1.03 ± 0.13 mGy. Prospectively ECG-triggered high-pitch CCTA at 70 kVp with 30 mL of contrast agent can provide diagnostic image quality at a radiation dose of less than 0.2 mSv in patients with a BMI of less than 25 kg/m{sup 2} and an HR of less than 70 bpm. (orig.)

  4. Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, F. (Dept. of Diagnostic Radiology, Malmoe Univ. Hospital, Univ. of Lund, Malmoe (Sweden)); Hansson, K.; Pasquariello, F. (Dept. of Internal Medicine, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, J. (Competence Center for Clinical Research, Univ. Hospital, Univ. of Lund, Lund (Sweden)); Nyman, U. (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden))

    2009-02-15

    Background: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. Purpose: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. Material and Methods: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR =50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 mumol/l from baseline. Results: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGycm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. Conclusion: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM

  5. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain

    International Nuclear Information System (INIS)

    Eide, Per Kristian; Ringstad, Geir

    2015-01-01

    Recently, the “glymphatic system” of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain

  6. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain.

    Science.gov (United States)

    Eide, Per Kristian; Ringstad, Geir

    2015-11-01

    Recently, the "glymphatic system" of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain.

  7. Effects of iodinated contrast media on common carotid and brachial artery blood flow and wall shear stress

    International Nuclear Information System (INIS)

    Irace, C.; Tamburini, S.; Bertucci, B.; Franceschi, M.S. de; Gnasso, A.

    2006-01-01

    The aim of our study was to evaluate the effect of the intravenous contrast media iomeprol on wall shear stress, blood flow and vascular parameters in the common carotid and brachial artery. Thirty outpatients undergoing thoracic or abdominal spiral CT scans were studied. The internal diameter and flow velocity of the common carotid and brachial artery were evaluated by ultrasound, and blood viscosity was measured before and after low osmolality iomeprol (Iomeron 350) injection. The wall shear stress, blood flow and pulsatility index were calculated. To test the differences between groups, the Wilcoxon rank test and Mann Whitney U test were applied. Blood viscosity decreased slightly, but significantly after contrast media (4.6±0.7 vs. 4.5±0.7 mPa.s, P=0.02). Contrarily, blood flow and wall shear stress did not change in the common carotid artery, but significantly decreased in the brachial artery (0.9±0.4 vs. 0.6±0.3 ml/s, P<0.0001, and 41.5±13.9 vs. 35.3±11.0 dynes/cm2, P<0.002, respectively), whereas the pulsatility index significantly increased in the brachial artery (5.0±3.3 vs. 7.5±5.3, P<0.001). Iomeprol injection causes blood flow and wall shear stress reduction of the brachial artery; the rise in the pulsatility index suggests an increase in peripheral vascular resistance. Further investigation is needed to evaluate whether these modifications can be clinically relevant. (orig.)

  8. The impact of iodinated X-ray contrast agents on formation and toxicity of disinfection by-products in drinking water.

    Science.gov (United States)

    Jeong, Clara H; Machek, Edward J; Shakeri, Morteza; Duirk, Stephen E; Ternes, Thomas A; Richardson, Susan D; Wagner, Elizabeth D; Plewa, Michael J

    2017-08-01

    The presence of iodinated X-ray contrast media (ICM) in source waters is of high concern to public health because of their potential to generate highly toxic disinfection by-products (DBPs). The objective of this study was to determine the impact of ICM in source waters and the type of disinfectant on the overall toxicity of DBP mixtures and to determine which ICM and reaction conditions give rise to toxic by-products. Source waters collected from Akron, OH were treated with five different ICMs, including iopamidol, iopromide, iohexol, diatrizoate and iomeprol, with or without chlorine or chloramine disinfection. The reaction product mixtures were concentrated with XAD resins and the mammalian cell cytotoxicity and genotoxicity of the reaction mixture concentrates was measured. Water containing iopamidol generated an enhanced level of mammalian cell cytotoxicity and genotoxicity after disinfection. While chlorine disinfection with iopamidol resulted in the highest cytotoxicity overall, the relative iopamidol-mediated increase in toxicity was greater when chloramine was used as the disinfectant compared with chlorine. Four other ICMs (iopromide, iohexol, diatrizoate, and iomeprol) expressed some cytotoxicity over the control without any disinfection, and induced higher cytotoxicity when chlorinated. Only iohexol enhanced genotoxicity compared to the chlorinated source water. Copyright © 2017. Published by Elsevier B.V.

  9. [Dynamic MR mammography. Multidimensional visualization of contrast medium enhancement in virtual reality].

    Science.gov (United States)

    Englmeier, K H; Griebel, J; Lucht, R; Knopp, M; Siebert, M; Brix, G

    2000-03-01

    The purpose of this study was the development of a method for fast and efficient analysis of dynamic MR images of the female breast. The image data sets were acquired with a saturation-recovery turbo-FLASH sequence which enables the detection of the kinetics of the contrast agent concentration in the whole breast with a high temporal and spatial resolution. In addition, a morphologic 3D-FLASH data set was acquired. The dynamic image datasets were analyzed by a pharmacokinetic model which enables the representation of the relevant functional tissue information by two parameters. In order to display simultaneously morphologic and functional tissue information, we developed a multidimensional visualization system, which enables a practical and intuitive human-computer interface in virtual reality. The developed system allows the fast and efficient analysis of dynamic MR data sets. An important clinical application is the localization and definition of multiple lesions of the female breast.

  10. Gadolinium DTPA as oral contrast medium for MRT of the pancreas

    International Nuclear Information System (INIS)

    Neumann, K.; Kaminsky, S.; Gogoll, M.; Langer, M.; Felix, R.

    1991-01-01

    52 patients with normal pancreas, pancreatitis and pancreatic tumors were examined by magnetic resonance imaging (Magnetom 0,5 T). Using T 1 -, proton density- and T 2 -weighted spin-echo sequences images were obtained before and after oral administration of Gadolinium-DTPA (Gd-DTPA, 1 mM, 15 g/l Mannit, 5-13 ml/kg). Gd-DTPA resulted in hyperintense labeling of small bowel in all sequences and improved visualization of pancreatic head, body and tail in 15, 14 and 7 of 27 patients with normal pancreas and in 17, 8 and 6 of 25 patients with diseased pancreas. Better delineation of pseudocysts and tumorous gut wall invasion were diagnostically profitable. With regard to motion artifact reduced MRI of the intestine using fast sequences Gd-DTPA may be a suitable oral contrast agent to improve the imaging of the pancreas. (orig.) [de

  11. Iodine Deficiency

    NARCIS (Netherlands)

    Zimmermann, M.B.

    2009-01-01

    Iodine deficiency has multiple adverse effects in humans, termed iodine deficiency disorders, due to inadequate thyroid hormone production. Globally, it is estimated that 2 billion individuals have an insufficient iodine intake, and South Asia and sub-Saharan Africa are particularly affected.

  12. Does MRI with oral contrast medium allow single-study depiction of inflammatory bowel disease enteritis and colitis?

    International Nuclear Information System (INIS)

    Cronin, Carmel G.; Lohan, Derek G.; Browne, Ann Michelle; Roche, Clare; Murphy, Joseph M.

    2010-01-01

    To assess the feasibility and utility of magnetic resonance (MR) imaging of the bowel in concurrent small- and large-bowel evaluation for the presence of inflammatory bowel disease (IBD). Over a 5-year period, 62 MR examinations performed on 53 patients demonstrated evidence of IBD. Sixteen of these 53 (30.1%) patients had imaging findings of colonic disease and underwent 19 formal MR small bowel examinations. These were further evaluated for bowel distention and image quality. The sensitivity and specificity of the technique compared with colonoscopy as the 'gold standard' was evaluated. Simultaneous imaging of the colon is feasible at MR small bowel follow-through with moderate-to-excellent colonic visibility and colon distention obtained when the contrast medium is present in the colon at the time of image acquisition. MR imaging had a sensitivity of 80% (0.56-0.93), specificity of 100% (0.77-1.00), positive predictive value (PPV) of 1 and a negative predictive value (NPV) of 0.8 for the identification of colitis (based on available concurrent correlation of 38/62 examinations with colonoscopy). Small and large bowel MR imaging with orally consumed contrast medium represents a promising, feasible, non-invasive, non-radiating single mode of assessment of the entire gastrointestinal tract, performed at a single sitting. (orig.)

  13. Radionuclide Basics: Iodine

    Science.gov (United States)

    ... Centers Radiation Protection Contact Us Share Radionuclide Basics: Iodine Iodine (chemical symbol I) is a chemical element. ... in the environment Iodine sources Iodine and health Iodine in the Environment All 37 isotopes of iodine ...

  14. Utility of vaginal and rectal contrast medium in MRI for the detection of deep pelvic endometriosis

    International Nuclear Information System (INIS)

    Chassang, M.; Novellas, S.; Bloch-Marcotte, C.; Chevallier, P.; Delotte, J.; Bongain, A.; Toullalan, O.

    2010-01-01

    To study the sensitivity of MRI performed utilising vaginal and rectal opacification with ultrasound gel in the detection of deep pelvic endometriosis. This was a prospective monocentric study. All patients evaluated by the gynaecologist for pelvic pain, endometriosis or infertility were included. Axial and sagittal T2-weighted images were performed both with and without vaginal and rectal opacification with ultrasound gel. Three radiologists, all blinded, interpreted the images with a minimum of 15 days between the two readings. MRI performance with and without vaginal and rectal opacification was evaluated by calculating sensitivity, specificity and both positive and negative predictive values. Seventy-eight patients were included. Among these, 31 patients had deep pelvic endometriosis of which 24 were confirmed by laparoscopy. Seventy-six locations of deep pelvic endometriosis were discovered on MRI. For the three reviewers there was a significant improvement in sensitivity between pre- and post-contrast MRI (p < 0.0002). Opacification of the vagina and rectum significantly improved the sensitivity of MRI for the detection of deep pelvic endometriosis by expanding the vagina and rectum, thus allowing better delineation of the pelvic organs. This was especially apparent for lesions localised to the vagina and rectovaginal septum. (orig.)

  15. Contrasting medium and genre on Wikipedia to open up the dominating definition and classification of geoengineering

    Directory of Open Access Journals (Sweden)

    Nils Markusson

    2016-08-01

    Full Text Available Geoengineering is typically defined as a techno-scientific response to climate change that differs from mitigation and adaptation, and that includes diverse individual technologies, which can be classified as either solar radiation management or carbon dioxide removal. We analyse the representation of geoengineering on Wikipedia as a way of opening up this dominating, if contested, model for further debate. We achieve this by contrasting the dominating model as presented in the encyclopaedic article texts with the patterns of hyper-link associations between the articles. Two datasets were created tracing the geoengineering construct on Wikipedia, shedding light on its boundary with its context, as well as on its internal structure. The analysis shows that the geoengineering category tends to be associated on Wikipedia primarily with atmospheric solar radiation management rather than land-based carbon dioxide removal type technologies. The results support the notion that the dominant model of defining and classifying geoengineering technology has been beneficial for solar radiation management type technologies more than for land-based carbon dioxide removal ones. The article also demonstrates that controversy mapping with Wikipedia data affords analysis that can open up dominating definitions and classifications of technologies, and offer resistance to their frequent naturalising and decontextualising tendencies. This work is in line with recent work on digital sociology, but the article contributes a new methodology and reports on the first empirical application of controversy mapping using Wikipedia data to a technology.

  16. Utility of vaginal and rectal contrast medium in MRI for the detection of deep pelvic endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Chassang, M.; Novellas, S.; Bloch-Marcotte, C.; Chevallier, P. [Hopital Archet 2, Service d' Imagerie Diagnostique et Interventionnelle, Centre Hospitalier Regional et Universitaire de Nice, 151 route de Saint Antoine de Ginestiere, B.P. 3079, Nice Cedex 3 (France); Delotte, J.; Bongain, A. [Hopital Archet 2, Service de Gynecologie-Obstetrique, Centre Hospitalier Regional et Universitaire de Nice, 151 route de Saint Antoine de Ginestiere, B.P. 3079, Nice Cedex 3 (France); Toullalan, O. [Hopital de Cannes, Service de Gynecologie, 15 avenue des Broussailles, B.P. 264, Cannes Cedex (France)

    2010-04-15

    To study the sensitivity of MRI performed utilising vaginal and rectal opacification with ultrasound gel in the detection of deep pelvic endometriosis. This was a prospective monocentric study. All patients evaluated by the gynaecologist for pelvic pain, endometriosis or infertility were included. Axial and sagittal T2-weighted images were performed both with and without vaginal and rectal opacification with ultrasound gel. Three radiologists, all blinded, interpreted the images with a minimum of 15 days between the two readings. MRI performance with and without vaginal and rectal opacification was evaluated by calculating sensitivity, specificity and both positive and negative predictive values. Seventy-eight patients were included. Among these, 31 patients had deep pelvic endometriosis of which 24 were confirmed by laparoscopy. Seventy-six locations of deep pelvic endometriosis were discovered on MRI. For the three reviewers there was a significant improvement in sensitivity between pre- and post-contrast MRI (p < 0.0002). Opacification of the vagina and rectum significantly improved the sensitivity of MRI for the detection of deep pelvic endometriosis by expanding the vagina and rectum, thus allowing better delineation of the pelvic organs. This was especially apparent for lesions localised to the vagina and rectovaginal septum. (orig.)

  17. Prediction of presence of kidney disease in patients undergoing intravenous iodinated contrast enhanced computed tomography: a validation study

    Energy Technology Data Exchange (ETDEWEB)

    Schreuder, Sanne M.; Stoker, Jaap; Bipat, Shandra [University of Amsterdam, Department of Radiology, Academic Medical Centre, G1-212, Amsterdam (Netherlands)

    2017-04-15

    To validate two previously presented models containing risk factors to identify patients with estimated glomerular filtration rate (eGFR) <60 ml/min/1.73 m{sup 2} or eGFR <45 ml/min/1.73 m{sup 2}. In random patients undergoing intravenous contrast-enhanced computed tomography (CECT) the following risk factors were assessed: history of urological/nephrological disease, hypertension, diabetes mellitus, anaemia, congestive heart failure, other cardiovascular disease or multiple myeloma or Waldenstroem disease. Data on kidney function, age, gender and type and indication of CECT were also registered. We studied two models: model A - diabetes mellitus, history of urological/nephrological disease, cardiovascular disease, hypertension; model B - diabetes mellitus, history of urological/nephrological disease, age >75 years and congestive heart failure. For each model, associations with eGFR <60 ml/min/1.73 m{sup 2} or eGFR <45 ml/min/1.73 m{sup 2} was studied. A total of 1,001 patients, mean age 60.36 years were included. In total, 92 (9.2 %) patients had an eGFR <60 ml/min/1.73 m{sup 2} and 11 (1.1 %) patients an eGFR <45 ml/min/1.73 m{sup 2}. Model A detected 543 patients: 81 with eGFR <60 ml/min/1.73 m{sup 2} (missing 11) and all 11 with eGFR <45 ml/min/1.73 m{sup 2}. Model B detected 420 patients: 70 (missing 22) with eGFR <60 ml/min/1.73 m{sup 2} and all 11 with eGFR <45 ml/min/1.73 m{sup 2}. Associations were significant (p < 0.05). Model B resulted in the lowest superfluous eGFR measurements while detecting all patients with eGFR <45 ml/min/1.73 m{sup 2} and nearly all with eGFR <60 ml/min/1.73 m{sup 2}. (orig.)

  18. Choice of intravenous contrast material for CT

    International Nuclear Information System (INIS)

    Cohen, M.D.; Herman, E.; Herron, D.; White, S.T.; Smith, J.A.; Cory, D.A.

    1989-01-01

    For CT, minor side effects (e.g., nausea, vomiting, pain) following intravenous administration of contrast medium may degrade image quality by causing patient motion or by delaying scanning. The objective of this study was to see if nonionic contrast agents offer advantages in reducing the incidence of such side effects. One hundred five pediatric patients randomly received iohexol (Omnipaque), Iopamidol (Isovue), or diatrizoate sodium (Hypaque). Contrast medium was given in doses of 2 mL/kg body weight (300 mg of iodine per milliliter). The results are presented in the paper

  19. Volatilization of iodine from vegetation

    Energy Technology Data Exchange (ETDEWEB)

    Amiro, B D; Johnston, F L [Atomic Energy of Canada Ltd., Pinawa, MB (Canada). Whiteshell Nuclear Research Establishment

    1989-01-01

    Gaseous emissions of iodine were measured from bean plant foliage. A gamma-emitting iodine tracer, Na {sup 125}I, was taken up by the plants from a hydroponic growth medium and released to a cuvette atmosphere. The dynamics of the flux were studied using a flow-through gamma detector. The relationship between leaf radioactive tracer activity and growth-medium activity was linear, as was the relationship between the iodine flux and both leaf and growth-medium activity. Iodine flux and leaf conductance to water responded similarly to changes in light levels, suggesting that the stomata may partially control the flux. The flux was inhibited by aeration of the hydroponic growth media, and we postulate that methylation causes the iodine flux. Iodine emissions from living vegetation probably contribute < 0.1% to the stable iodine concentration in the atmosphere above terrestrial areas. However, this pathway may be a direct route for radioactive iodine transport from contaminated soils to the atmosphere. (author).

  20. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  1. Effects of acetylcysteine and probucol on contrast medium-induced depression of intrinsic renal glutathione peroxidase activity in diabetic rats.

    Science.gov (United States)

    Yen, Hsueh-Wei; Lee, Hsiang-Chun; Lai, Wen-Te; Sheu, Sheng-Hsiung

    2007-04-01

    Antioxidants such as N-acetylcysteine and probucol have been used to protect patients from contrast media-induced nephrotoxicity. The mechanisms underlying these protective effects are not well understood. We hypothesized that acetylcysteine and probucol alter the activity of endogenous antioxidant enzyme activity. Four weeks after induction of diabetes with streptozotocin, diabetic and nondiabetic rats were divided into three groups. Group 1 rats did not receive any antioxidant agents. Group 2 rats were treated with acetylcysteine and group 3 rats with probucol for 1 week before injection of the contrast medium diatrizoate (DTZ). We found that diabetic rats had higher renal glutathione peroxidase (GPx) activity than normal rats. DTZ suppressed renal GPx activity significantly in both group 1 diabetic and normal rats. Interestingly, renal GPx activity in both diabetic and normal rats pretreated with acetylcysteine or probucol was not inhibited by DTZ. Renal superoxide dismutase (SOD) increased significantly in normal rats after DTZ injection, but not in diabetic rats. Finally, acetylcysteine or probucol did not significantly influence renal SOD. These findings suggest that the renal protective effects of acetylcysteine and probucol against contrast-induced oxidative stress and nephrotoxicity may be mediated by altering endogenous GPx activity.

  2. The interaction of radiographic contrast media with immune globulins

    International Nuclear Information System (INIS)

    Bauer, K.

    1983-01-01

    As a special form of contrast medium incidents, various reaction modes between iodinated contrast media and immunoglobulins are described. Theoretical explanations and typical examples are given for each of the four different possible action mechanisms. Diagnostic precautions are proposed in order to avoid unfavourable reactions especially with paraproteins. Special attention is drawn to the antigen-antibody like reaction between iodinated contrast media and IgM paraproteins. Some immunological criteria are recalled to attention, this type of reaction has to meet stringently. Only by this, misinterpretations of inevident conclusions from analogy can be prevented in future similar cases. (orig.) [de

  3. Determination of iodine at ppt level in a nitric acid medium by inductively coupled plasma sector field mass spectrometry: influence of the chemical forms

    International Nuclear Information System (INIS)

    Langlois, B.

    2001-01-01

    Inductively Coupled Plasma Sector Field Mass Spectrometry (ICP/SFMS) was used to determine several chemical forms of iodine, at ppt level, in a nitric acid media. Ascorbic acid was added as a reducing agent in order to maintain iodine as iodide. In a preliminary approach, the influence of the chemical form was studied by comparing inorganic iodine (NaI) and organic iodine (CH3I). Different signal responses were observed. With a conventional sample introduction system, sensitivities obtained for iodo-methane could differ by a factor of 5. This was not caused by a problem of atomization or by a change in the ionization efficiency of the iodo-compound into the plasma. The low volatilization temperature of iodo-methane (315.5 K) seemed to be the main explanation of this phenomena. Actually, nebulization resulted in the volatilization of a 2% nitric acid solution containing iodo-methane. As a result, the transport efficiency of iodo-methane between the nebulizer and the torch was approaching 100%. A Direct Injection High Efficiency Nebulizer (DIHEN) allowed us to minimize the behavior difference between the two iodine species, but the sensitivity ratio was inverted and still differed by 20 - 40%. Moreover, the association of a guard electrode and the direct injection system was studied in order to apply these equipments to the determination of iodine. This association allowed us to improve the sensitivity by a factor of 10 and to minimize memory effects, when compared with a conventional system. Further studies indicated that signal responses obtained with different iodine-containing species, except for iodo-methane, were found to be similar. (author)

  4. Degradation of Iodinated Contrast Media in Aquatic Environment by Means of UV, UV/TiO2 Process, and by Activated Sludge.

    Science.gov (United States)

    Borowska, Ewa; Felis, Ewa; Żabczyński, Sebastian

    Iodinated contrast media (ICM), which are used for radiological visualization of human tissue and cardiovascular system, are poorly biodegradable; hence, new methods of their removal are sought. In this study, the effectiveness of selected X-ray ICM removal by means of UV and UV/TiO 2 pretreatment processes from synthetic hospital wastewater was demonstrated. The following compounds were investigated: iodipamide, iohexol, and diatrizoate. The experiments were as follows: (i) estimated susceptibility of the ICM to decay by UV radiation in different aquatic matrices, (ii) determined an optimal retention time of hospital wastewater in the UV reactor, (iii) determined optimum TiO 2 concentration to improve the effectiveness of the UV pretreatment, and (iv) investigated removal of ICM by combination of the photochemical and biological treatment methods. The quantum yields of selected ICM decay in deionized water (pH = 7.0) were established as 0.006, 0.004, and 0.029 for iohexol, diatrizoate, and iodipamide, respectively. Furthermore, the experiments revealed that diatrizoate and iohexol removal in the UV/TiO 2 process is more efficient than in UV process alone. For diatrizoate, the removal efficiency equaled to 40 and 30 %, respectively, and for iohexol, the efficiency was 38 and 27 %, respectively. No significant increase in iodipamide removal in UV and UV/TiO 2 processes was observed (29 and 28 %, respectively). However, highest removal efficiency was demonstrated in synthetic hospital wastewater with the combined photochemical and biological treatment method. The removal of diatrizoate and iohexol increased to at least 90 %, and for iodipamide, to at least 50 %.

  5. Reductive and oxidative degradation of iopamidol, iodinated X-ray contrast media, by Fe(III)-oxalate under UV and visible light treatment.

    Science.gov (United States)

    Zhao, Cen; Arroyo-Mora, Luis E; DeCaprio, Anthony P; Sharma, Virender K; Dionysiou, Dionysios D; O'Shea, Kevin E

    2014-12-15

    Iopamidol, widely employed as iodinated X-ray contrast media (ICM), is readily degraded in a Fe(III)-oxalate photochemical system under UV (350 nm) and visible light (450 nm) irradiation. The degradation is nicely modeled by pseudo first order kinetics. The rates of hydroxyl radical (OH) production for Fe(III)-oxalate/H2O2/UV (350 nm) and Fe(III)-oxalate/H2O2/visible (450 nm) systems were 1.19 ± 0.12 and 0.30 ± 0.01 μM/min, respectively. The steady-state concentration of hydroxyl radical (OH) for the Fe(III)-oxalate/H2O2/UV (350 nm) conditions was 10.88 ± 1.13 × 10(-14) M and 2.7 ± 0.1 × 10(-14) M for the Fe(III)-oxalate/H2O2/visible (450 nm). The rate of superoxide anion radical (O2(-)) production under Fe(III)-oxalate/H2O2/UV (350 nm) was 0.19 ± 0.02 μM/min with a steady-state concentration of 5.43 ± 0.473 × 10(-10) M. Detailed product studies using liquid chromatography coupled to Q-TOF/MS demonstrate both reduction (multiple dehalogenations) and oxidation (aromatic ring and side chains) contribute to the degradation pathways. The reduction processes appear to be initiated by the carbon dioxide anion radical (CO2(-)) while oxidation processes are consistent with OH initiated reaction pathways. Unlike most advanced oxidation processes the Fe(III)-oxalate/H2O2/photochemical system can initiate to both reductive and oxidative degradation processes. The observed reductive dehalogenation is an attractive remediation strategy for halogenated organic compounds as the process can dramatically reduce the formation of the problematic disinfection by-products often associated with oxidative treatment processes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Digital subtraction angiography (DSA) of aortocoronary bypass grafts in the early postoperative phase with peripheral-venous contrast medium injection

    International Nuclear Information System (INIS)

    Tuengerthal, S.; Lang, J.; Donhoeffner, A.

    1985-01-01

    Using a fully digitalised subtraction unit, aortocoronary bypass grafts can be visualised in the early postoperative phase by means of peripheral venous contrast medium injection (57 out of a total of 60 cases). In more than one-half of the cases (31 out of a total of 60), it is possible to outline sharply the bypass grafts from the beginning to their entry into the bridged-over coronary artery, in such a manner that any loops, kinks, stenoses or reduced flow rates can be recognised. This examination is not considered to be an invasive one by the patient, and the cardiosurgeon can welcome it as a valuable additional means of controlling and assessing the results of surgery. (orig.) [de

  7. 2D and 3D parameter images for analysis of contrast medium enhancement based on dynamic CT and MR

    International Nuclear Information System (INIS)

    Beier, J.; Stroszczynski, C.; Oellinger, H.; Felix, R.; Buege, T.; Fleck, E.

    1998-01-01

    Aim: For dynamic contrast medium (CM) studies, parameter images exploit specific features of the time/intensity curve (TIC) of each pixel and represent these values in a new image. Existing concepts of two-dimensional CM analysis are extended for three-dimensional applications using adequate computer graphic visualization. Results: In first-pass analyses, TMIP and TG allowed the simultaneous or separted presentation of different temporal phases of the CM bolus. Correlation images emphasized regions with similarities to given TIC patterns. Three-dimensional computer graphic techniques enabled (1) anatomical/function mapping of original image and CM accumulation and (2) fused display of both spatial CM enhancement and color-encoded time of TIC peak in one common image. Conclusions: The quantifiction of presence, magnitude, and time-of-peak of CM accumulation in local image regions supports the assessment of vascularization and of ischemic or necrotic areas. (orig./AJ) [de

  8. Kinetics of intravenous radiographic contrast medium injections as used on CT: simulation with time delay differential equations in a basic human cardiovascular multicompartment model.

    Science.gov (United States)

    Violon, D

    2012-12-01

    To develop a multicompartment model of only essential human body components that predicts the contrast medium concentration vs time curve in a chosen compartment after an intravenous injection. Also to show that the model can be used to time adequately contrast-enhanced CT series. A system of linked time delay instead of ordinary differential equations described the model and was solved with a Matlab program (Matlab v. 6.5; The Mathworks, Inc., Natick, MA). All the injection and physiological parameters were modified to cope with normal or pathological situations. In vivo time-concentration curves from the literature were recalculated to validate the model. The recalculated contrast medium time-concentration curves and parameters are given. The results of the statistical analysis of the study findings are expressed as the median prediction error and the median absolute prediction error values for both the time delay and ordinary differential equation systems; these are situated well below the generally accepted maximum 20% limit. The presented program correctly predicts the time-concentration curve of an intravenous contrast medium injection and, consequently, allows an individually tailored approach of CT examinations with optimised use of the injected contrast medium volume, as long as time delay instead of ordinary differential equations are used. The presented program offers good preliminary knowledge of the time-contrast medium concentration curve after any intravenous injection, allowing adequate timing of a CT examination, required by the short scan time of present-day scanners. The injected volume of contrast medium can be tailored to the individual patient with no more contrast medium than is strictly needed.

  9. Iodine-131 imaging using 284 keV photons with a small animal CZT-SPECT system dedicated to low-medium-energy photon detection.

    Science.gov (United States)

    Kojima, Akihiro; Gotoh, Kumiko; Shimamoto, Masako; Hasegawa, Koki; Okada, Seiji

    2016-02-01

    Iodine-131 is widely used for radionuclide therapy because of its β-particle and for diagnostic imaging employing its principal gamma ray. Since that principal gamma ray has the relatively high energy of 364 keV, small animal single-photon emission computed tomography (SPECT) imaging systems may be required to possess the ability to image such higher energy photons. The aim of this study was to investigate the possibility of imaging I-131 using its 284 keV photons instead of its 364 keV photons in a small animal SPECT imaging system dedicated to the detection of low-medium-energy photons (below 300 keV). The imaging system used was a commercially available preclinical SPECT instrument with CZT detectors that was equipped with multi-pinhole collimators and was accompanied by a CT imager. An energy window for I-131 imaging was set to a photopeak of 284 keV with a low abundance compared with 364 keV photons. Small line sources and two mice, one of each of two types, that were injected with NaI-131 were scanned. Although higher counts occurred at the peripheral region of the reconstructed images due to the collimator penetration by the 364 keV photons, the shape of the small line sources could be well visualized. The measured spatial resolution was relatively poor (~1.9 mm for full width at half maximum and ~3.9 mm for full width at tenth maximum). However, a good linear correlation between SPECT values and the level of I-131 radioactivity was observed. Furthermore, the uptake of NaI-131 to the thyroid gland for the two mice was clearly identified in the 3D-SPECT image fused with the X-ray CT image. We conclude that the use of an energy window set on the photopeak of 284 keV and the multi-pinhole collimator may permit I-131 imaging for a preclinical CZT-SPECT system that does not have the ability to acquire images using the 364 keV photons.

  10. MO-F-CAMPUS-J-01: Effect of Iodine Contrast Agent Concentration On Cerebrovascular Dose for Synchrotron Radiation Microangiography Based On a Simple Mouse Head Model and a Voxel Mouse Head Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lin, H; Jing, J; Xie, C [Hefei University of Technology, Hefei (China); Lu, Y [Shanghai Jiao Tong University, Shanghai (China)

    2015-06-15

    Purpose: To find effective setting methods to mitigate the irradiation injure in synchrotron radiation microangiography(SRA) by Monte Carlo simulation. Methods: A mouse 1-D head model and a segmented voxel mouse head phantom were simulated by EGSnrc/Dosxyznrc code to investigate the dose enhancement effect of the iodine contrast agent irradiated by a monochromatic synchrotron radiation(SR) source. The influence of, like iodine concentration (IC), vessel width and depth, with and without skull layer protection and the various incident X ray energies, were simulated. The dose enhancement effect and the absolute dose based on the segmented voxel mouse head phantom were evaluated. Results: The dose enhancement ratio depends little on the irradiation depth, but strongly on the IC, which is linearly increases with IC. The skull layer protection cannot be ignored in SRA, the 700µm thick skull could decrease 10% of the dose. The incident X-ray energy can significantly affact the dose. E.g. compared to the dose of 33.2keV for 50mgI/ml, the 32.7keV dose decreases 38%, whereas the dose of 33.7 keV increases 69.2%, and the variation will strengthen more with enhanced IC. The segmented voxel mouse head phantom also showed that the average dose enhancement effect and the maximal voxel dose per photon depends little on the iodine voxel volume ratio, but strongly on IC. Conclusion: To decrease dose damage in SRA, the high-Z contrast agent should be used as little as possible, and try to avoid radiating locally the injected position immediately after the contrast agent injection. The fragile vessel containing iodine should avoid closely irradiating. Avoiding irradiating through the no or thin skull region, or appending thin equivalent material from outside to protect is also a better method. As long as SRA image quality is ensured, using incident X-ray energy as low as possible.

  11. Investigation of the gastrointestinal tract by means of the first dimerous nonionic x-ray contrast medium (Iotrolan)

    International Nuclear Information System (INIS)

    Troger, J.; Wenzel-Hora, B.I.

    1987-01-01

    The risks with an ionic, water solvent highly osmotic contrast medium (CM) have now led to a monomerous, nonionic CM being used, particularly in the field of gastrointestinal investigation in newborn babies and infants. Thus side effects could be reduced and the quality of the x-rays improved. However, since the monomerous nonionic CM is still hyperosmotic with respect to blood, there is a water shift into the intestinal lumen. This can upset hydration and impair the quality of radiographs. Iotrolan is the first CM isoosmotic to the blood to be used clinically. It has proved to be superior to a monomerous nonionic CM as far as radiographic quality (density and sharpness) is concerned. Fifty-one children, aged 2 days to 19 years, were give Iotrolan. Some of these patients were compared in a double-blind study with a group of children who had been given monomerous nonionic CM. If Iotrolan was given, the good quality of the radiographs remained constant throughout the gastrointestinal tract and details were clearly discernible, even in the rectum. In addition, Iotrolan in the aboral intestinal sections leads to double-contrast pictures and thereby further increases the identifiability of details. The monomerous nonionic CM, however, showed a loss in density and above all in sharpness during its passage. Since Iotrolan is isotonic to blood, its is superior to all other water-solvent CM as far as possible side effects and radiographic quality are concerned

  12. Contrast medium at the site of the anastomosis is crucial in detecting anastomotic leakage with CT imaging after colorectal surgery.

    Science.gov (United States)

    Huiberts, Astrid A M; Dijksman, Lea M; Boer, Simone A; Krul, Eveline J T; Peringa, Jan; Donkervoort, Sandra C

    2015-06-01

    The use of computed tomography (CT) to detect anastomotic leakage (AL) is becoming the standard of care. Accurate detection of AL is crucial. The aim of this study was to define CT criteria that are most predictive for AL. From January 2006 to December 2012, all consecutive patients who had undergone CT imaging because of clinical suspicion of anastomotic leakage after colorectal surgery were analysed. All CT scans were re-evaluated by two independent abdominal radiologists blinded for clinical outcome. The images were scored with a set of criteria and a conclusion whether or not AL was present was drawn. Each separate criterion was analysed for its value in predicting AL by uni- and multivariable logistic regression Of 668 patients with colorectal surgery, 108 had undergone CT imaging within 16 days postoperatively. According to our standard of reference, 34 (31%) of the patients had AL. Univariable analysis showed that "fluid near anastomosis" (radiologist 1 (rad 1), p leakage" (rad 1, p leakage was the only independent predictor for AL in multivariable analysis for both radiologists (rad 1, OR 5.43 (95% CI 1.18-25.02); rad 2, OR 8.51 (95% CI 2.21-32.83)). The only independent variable predicting AL is leakage of contrast medium. To improve the accuracy of CT imaging, optimal contrast administration near the anastomosis appears to be crucial.

  13. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT--a pooled analysis of two randomized trials

    DEFF Research Database (Denmark)

    Thomsen, Henrik S; Morcos, Sameh K

    2009-01-01

    of the LOCM were also observed in patients with GFR contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM......The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients...... with glomerular filtration rate (GFR) contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients...

  14. RCR audit of compliance with UK guidelines for the prevention and detection of acute kidney injury in adult patients undergoing iodinated contrast media injections for CT.

    Science.gov (United States)

    Cope, L H; Drinkwater, K J; Howlett, D C

    2017-12-01

    To determine radiology departmental compliance with current UK guidance on contrast-induced acute kidney injury (CI-AKI) and to provide data on the incidence of clinically significant post-contrast AKI (PC-AKI) in computed tomography (CT) practice. A questionnaire was sent to all UK acute National Health Service (NHS) providers (NHS boards in Scotland, local health boards in Wales, NHS trusts in England and health and social care trusts in Northern Ireland) to assess compliance of provider protocols with current UK guidelines for the prevention, recognition, and management of CI-AKI. Audit data were collected for 40 consecutive fit outpatients and 40 consecutive acutely unwell patients/inpatients from hospitals within each participating provider to assess clinical compliance. Eighty-nine of 172 (52%) health service providers responded, and data on 7,159 contrast-enhanced CT examinations were provided. Compliance with guidelines was poor with wide variation in clinical practice. The observed incidence of clinically significant (requiring treatment or resulting in death) PC-AKI was zero in 3,590 outpatients, although two patients developed AKI due to other causes (sepsis and progressive malignancy). Fourteen out of 3,569 (0.4%) patients in the inpatient group developed clinically significant PC-AKI, and a further 17 patients were identified who met the Kidney Disease Improving Global Outcomes (KDIGO) definition of AKI (Electronic Supplementary Material Appendix S1), but did not require active treatment, giving an overall incidence of AKI of 0.9%. In patients at high risk due to impaired renal function prior to the scan, there was no difference in the median serum creatinine (SCr) before and after contrast medium administration in either group. Health service provider protocols and clinical practice demonstrate poor compliance with current UK guidance on CI-AKI. A very low incidence of PC- AKI was demonstrated. Copyright © 2017 The Royal College of Radiologists

  15. Initial Experience of Using Dual-Energy CT with an Iodine Overlay Image for Hand Psoriatic Arthritis: Comparison Study with Contrast-enhanced MR Imaging.

    Science.gov (United States)

    Fukuda, Takeshi; Umezawa, Yoshinori; Tojo, Shinjiro; Yonenaga, Takenori; Asahina, Akihiko; Nakagawa, Hidemi; Fukuda, Kunihiko

    2017-07-01

    Purpose To determine the feasibility of dual-energy (DE) computed tomography (CT) with an iodine overlay image (IOI) for evaluation of psoriatic arthritis in the hand. Materials and Methods Approval from the institutional ethics committee and written informed consent from all patients were obtained. This prospective study included 16 patients who had psoriasis with finger joint symptoms from January 2015 to January 2016. Contrast material-enhanced (CE) DE CT and 1.5-T CE magnetic resonance (MR) imaging were performed within 1 month of each other. DE CT was performed with a tube voltage of 80 kV and 140 kV with use of a 0.4-mm tin filter. Images acquired with both modalities were evaluated by two radiologists independently by using a semiquantitative scoring system. Interreader agreement was calculated for each modality: Weighted κ values were calculated for synovitis, flexor tenosynovitis, and extensor peritendonitis, and κ values were calculated for periarticular inflammation. With consensus scores and CE MR images as the reference, the sensitivity and specificity of IOI DE CT for inflammatory lesions were calculated. Statistical analysis of discordant readings was performed by using the McNemar test. Results Interreader agreement for inflammatory lesions was excellent or good (weighted κ = 0.83 and κ = 0.75 in IOI DE CT; weighted κ = 0.81 and κ = 0.87 in CE MR imaging). The sensitivity and specificity of IOI DE CT were 0.78 and 0.87, respectively. Total agreement was 86.3%; however, there were significantly more lesions detected with IOI DE CT than with CE MR imaging alone (134 vs 20 lesions in 1120 evaluated items; P the abnormalities detected with IOI DE CT alone were located in distal interphalangeal joints. Conclusion IOI DE CT is a new imaging modality that may be useful for evaluating psoriatic arthritis in the hand, particularly in the detection of inflammatory lesions in small joints, and may be more useful than CE MR imaging, within the limitation

  16. Iodinated bleomycin

    International Nuclear Information System (INIS)

    Lunghi, F.; Riva, P.; Assone, F.; Villa, M.; Plassic, G.

    1978-01-01

    Bleomycin was labelled with iodine-131 by the iodine monochloride method. Iodination did not alter the chemical and chromatographic features and ''in vitro'' stability studies on freeze-dried 131 I-Bleomycin having a specific activity of 1 mCi/mg, stored at different temperatures, showed no appreciable variation of the free-iodine content. Tissue distribution of 131 I-Bleomycin has been evaluated in tumor bearing rats. Patients have been injected with 0.5-1.0 mCi of 131 I-Bleomycin corresponding to a maximum of 1.5 mg. No adverse reactions have been observed. Total body scans have been performed at 2, 6, 24 and 48 hours after injection. The iodinated Bleomycin was rapidly distributed and cleared from the body and showed an early uptake in the neoplastic tissue. A diagnostic accuracy of 90% has been observed in malignant deseases, while no false positive results have been, at the moment, recorded. (author)

  17. The influence of different contrast medium concentrations and injection protocols on quantitative and clinical assessment of FDG–PET/CT in lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Berlin, Müllerstrasse 178, 13353 Berlin (Germany); Palmowski, Moritz [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-10-01

    Objectives: To compare the effects of two different contrast medium concentrations for use in computed X-ray tomography (CT) employing two different injection protocols on positron emission tomography (PET) reconstruction in combined 2-{sup 18}F-desoxyglucose (FDG) PET/CT in patients with a suspicion of lung cancer. Methods: 120 patients with a suspicion of lung cancer were enrolled prospectively. PET images were reconstructed with the non-enhanced and venous phase contrast CT obtained after injection of iopromide 300 mg/ml or 370 mg/ml using either a fixed-dose or a body surface area adapted injection protocol. Maximum and mean standardized uptake values (SUVmax and SUVmean) and contrast enhancement (HU) were determined in the subclavian vein, ascending aorta, abdominal aorta, inferior vena cava, portal vein, liver and kidney and in the suspicious lung lesion. PET data were evaluated visually for the presence of malignancy and image quality. Results: At none of the sites a significant difference in the extent of the contrast enhancement between the four different protocols was found. However, the variability of the contrast enhancement at several anatomical sites was significantly greater in the fixed dose groups than in the BSA groups for both contrast medium concentrations. At none of the sites a significant difference was found in the extent of the SUVmax and SUVmean increase as a result of the use of the venous phase contrast enhanced CT for attenuation. Visual clinical evaluation of lesions showed no differences between contrast and non-contrast PET/CT (P = 0.32). Conclusions: Contrast enhanced CT for attenuation correction in combined PET/CT in lung cancer affects neither the clinical assessment nor image quality of the PET-images. A body surface adapted contrast medium protocol reduces the interpatient variability in contrast enhancement.

  18. MRI cisternography with gadolinium-containing contrast medium: its role, advantages and limitations in the investigation of rhinorrhoea.

    Science.gov (United States)

    Aydin, K; Guven, K; Sencer, S; Jinkins, J R; Minareci, O

    2004-01-01

    Our purpose was to evaluate the utility of intrathecal gadopentetate dimeglumine -enhanced magnetic resonance cisternography (GdMRC). We injected 0.5 ml contrast medium into the subarachnoid space via lumbar puncture in 20 patients with suspected cerebrospinal fluid (CSF) rhinorrhoea. MRC showed CSF leakage in 14 patients with rhinorrhoea at the time of the examination, into the ethmoid air cells in nine, the sphenoid sinus in three and the frontal sinus in two cases. In 12 of these the site leakage was confirmed during surgical repair of the fistula. No leakage was observed in four patients with intermittent rhinorrhoea, not present at the time of the examination. GdMRC showed leakage in two patients with negative CT cisternography. GdMRC may prove better than CT cisternography, especially with slow CSF flow. We also showed low-dose GdMRC to be a feasible and relative safe way of confirming the presence of and localising active CSF leaks prior to surgical repair.

  19. MRI cisternography with gadolinium-containing contrast medium: its role, advantages and limitations in the investigation of rhinorrhoea

    International Nuclear Information System (INIS)

    Aydin, K.; Guven, K.; Sencer, S.; Minareci, O.; Jinkins, J.R.

    2004-01-01

    Our purpose was to evaluate the utility of intrathecal gadopentetate dimeglumine -enhanced magnetic resonance cisternography (GdMRC). We injected 0.5 ml contrast medium into the subarachnoid space via lumbar puncture in 20 patients with suspected cerebrospinal fluid (CSF) rhinorrhoea. MRC showed CSF leakage in 14 patients with rhinorrhoea at the time of the examination, into the ethmoid air cells in nine, the sphenoid sinus in three and the frontal sinus in two cases. In 12 of these the site leakage was confirmed during surgical repair of the fistula. No leakage was observed in four patients with intermittent rhinorrhoea, not present at the time of the examination. GdMRC showed leakage in two patients with negative CT cisternography. GdMRC may prove better than CT cisternography, especially with slow CSF flow. We also showed low-dose GdMRC to be a feasible and relative safe way of confirming the presence of and localising active CSF leaks prior to surgical repair. (orig.)

  20. The experimental study of the effect of dexamethasone, lidocaine and contrast medium on the activity of collagenase

    International Nuclear Information System (INIS)

    Wu Zhiqun; Liu Weimin; Li Zhonghua; Yang Peng

    2007-01-01

    Objective: To study the effects of hormone, anesthetic and contrast medium on the activities of collagenase lysis. Methods: Nuclear tissues were divided into equal amount for different groups and same units of collagenase were used for the lysis. The only difference in the control group from experimental groups was that there were no dexamethasone, lidocaine or omnipaque but existing in experimental groups. Twenty four hours later, the concentrations of the hydroxyproline were determined in different groups and the data were analyzed by statistical software with computer. Results: 1. The concentrations of hydroxyproline in the dexamethasone group, lidocaine group and omnipaque group were significantly lower than that of control group, especially that of lidocaine group, P value was <0.05 or 0.01. 2. The concentrations of hydroxyproline in the dexamethasone + lidocaine group, dexamethasone + omnipaque group, lidocaine+omnipaque group and dexamethasone + lidocaine + omnipaque group were significantly lower than that of control group; and simultaneously lower in dexamethasone group, lidocaine group, omnipaque group respectively; P value was also <0.05 or 0.01. Conclusion: Dexamethasone, lidocaine and omnipaque can individually inhibit the activity of collagenase at different degrees, so they shouldn't be used together with collagenase in treating the lumber disc herniation. (authors)

  1. Intra-arterial digital subtraction portography with a blood-isotonic, non-ionic, dimeric contrast medium

    International Nuclear Information System (INIS)

    Minakuchi, Kazuo; Tamaoka, Koichi; Nishio, Hiroshi; Matsuo, Ryoichi; Takada, Keiji; Morimoto, Atsuko; Toyoshima, Masami; Murata, Katsuko; Onoyama, Yasuto

    1993-01-01

    Intra-arterial digital subtraction portography (IA-DSP) with a blood-isotonic, non-ionic, dimeric contrast medium was carried out in 27 patients with hepatocellular carcinoma. It was possible to obtain images of excellent or good quality of the portal vein and its bilateral main branches in all patients. The third-order branches of the portal vein in the right lobe could be identified in all patients, and images of excellent or good quality were obtained in a mean of 80.2% of patients. Images of third-order branches in the left lobe were of lower quality than those of third-order branches in the right lobe; in particular, images obtained were of poor quality for 27.3% of the medial branches of the left lobe. It was impossible to identify the caudal branches in almost all patients. The side effects of IA-DSP, pain and sensations of heat were very mild; only one patient complained of mild pain, while 18 patients (69.2%) complained of no sensations of heat whatsoever. (author)

  2. Experimental investigations on the influence of the contrast medium Iopamiro 300 mixed with vegetal mucus on the nasolacrimal system and external eye tissues

    International Nuclear Information System (INIS)

    Rubaj, B.; Koper, S.; Wolski, T.; Toczowski, J.; Wolski, J.; Langwinska-Wosko, E.

    1994-01-01

    Using low osmolality, nonionized contrast medium Iopamiro-300, Bracco mixed with the mucus prepared from the seed flax (''Linum usitatissimum, L.''), a dacryocistorhinography was performed experimentally on 8 healthy mongrel dogs. Assessing the occurrence of local and general complications was the aim of the investigation. On the basis of a radiographic examination it has been shown that the mixture of the contrast medium and seed flax mucus appeared to be a very useful compound for dacryocistorhinography, especially for the evaluation of nasolacrimal duct system course and its patency. Clinical observations and a histological examination proved that this compound of the contrast medium was well tolerated by the mucous membrane of the nasolacrimal system and the external eye tissues. (author). 21 refs, 4 figs

  3. Polysorbate 80 and low-osmolality water-soluble contrast medium enema in diagnosis and treatment of faecal obstruction in malignant phaeochromocytoma

    International Nuclear Information System (INIS)

    Ratcliffe, J.F.

    1986-01-01

    Stercoral obstruction in a young woman with disseminated phaeochromocytoma was diagnosed and treated successfully using an enema of isosmolar iohexol (Omnipaque) and 1% polysorbate 80 (Tween 80) without complication. Surgical intervention was thus avoided. A low osmolality water-soluble contrast medium (iohexol 150 mg I/ml) with a wetting agent (1% Tween 80) was used because a barium suspension would have inspissated, exacerbating the constipation and a hyperosmolar contrast medium might have precipitated a hypertensive crisis and destablished her critical salt and water balance. (orig.)

  4. Estudo comparativo dos meios de contraste baritado e iodado-iônico e não-iônico no trato respiratório de ratos Comparative study of barium and iodine agents - ionic and nonionic on the respiratory tract of the rats

    Directory of Open Access Journals (Sweden)

    Maria de Lourdes Pessole Biondo-Simões

    2003-10-01

    determine the changes in the respiratory tract triggered by the presence of contrast medium. METHODS: Ninety-one rats were divided at random into 5 groups, i.e., an intact control group of 7 animals and 4 groups of 21 rats each. The manipulated control group received physiological saline and the experimental groups respectively received barium, ionic iodine and non-ionic iodine. Under anesthesia and direct visualization of the trachea, 0.75 ml/kg (0.25 ml of the contrast medium was injected into the animals of each group. The effects of the procedure were determined after 1 hour, 1 day and 1 week, with the animals being sacrificed at each time point by drawing lots. Radiographic documentation was obtained, followed by resection and histopathologic examination of the lungs. RESULTS: After 1 hour, the middle fields and the right upper field were involved in the group injected with barium. In the groups injected with ionic iodine and non-ionic iodine, the entire right lung was found to be opacified. After 1 day and 1 week, the groups injected with iodine were normal, whereas the group injected with barium showed involvement of the middle fields. After 1 week, histopathologic examination revealed that the group injected with barium exhibited large amounts of intra-alveolar, perivascular and peribronchial macrophages CONCLUSION: The ionic and non-ionic iodine contrast media led to temporary changes, whereas barium promoted a chronic inflammatory reaction with maintenance of radiographic translation.

  5. Multi-detector CT urography: effect of oral hydration and contrast medium volume on renal parenchymal enhancement and urinary tract opacification - a quantitative and qualitative analysis

    International Nuclear Information System (INIS)

    Szolar, Dieter H.; Tillich, Manfred; Preidler, Klaus W.

    2010-01-01

    To assess the effect of oral hydration and contrast-medium volume on renal enhancement and urinary tract opacification in multi-detector CT urography. A total of 192 patients were assigned to different protocols with varying doses of contrast agent with and without oral hydration. The attenuation was measured in the renal parenchyma in the unenhanced, nephrographic and excretory phase, and in the urinary tract in excretory phase imaging, respectively. Opacification of the urinary tract was graded on volume rendered images. Oral hydration did not significantly alter renal parenchymal enhancement in both the nephrographic and the excretory phase (p > 0.001), but significantly decreased mean attenuation of the urinary tract in the excretory phase (p ≤ 0.001), and improved continuous opacification of all ureter segments (p < 0.01). Higher volumes of contrast medium improved renal parenchymal enhancement (p ≤ 0.001) and continuous opacification of the urinary tract (p ≤ 0.01). Oral hydration leads to lower attenuation values in the urinary tract but improves the continuous opacification of the tract. Increase in contrast medium volume leads to higher renal parenchymal enhancement as well as to an increased continuous opacification of the urinary tract. Decrease in contrast medium volume cannot be compensated for by oral hydration in terms of parenchymal enhancement. (orig.)

  6. Clinical observation of the adverse drug reactions caused by non-ionic iodinated contrast media: results from 109,255 cases who underwent enhanced CT examination in Chongqing, China.

    Science.gov (United States)

    Li, X; Chen, J; Zhang, L; Liu, H; Wang, S; Chen, X; Fang, J; Wang, S; Zhang, W

    2015-03-01

    To analyse the pattern and factors that influence the incidence of adverse drug reactions (ADRs) induced by non-ionic iodinated contrast media and to evaluate their safety profiles. Data from 109,255 cases who underwent enhanced CT examination from 1 January 2008 to 31 August 2013 were analysed. ADRs were classified according to the criteria issued by the American College of Radiology and the Chinese Society of Radiology. A total of 375 (0.34%) patients had ADRs, including 281 mild (0.26%); 80 moderate (0.07%); and 14 severe (0.01%) ADRs; no death was found. 302 (80.53%) of the ADRs occurred within 15 min after examination. Patients aged 40-49 years (204 cases, 0.43%; p contrast media are mainly mild ones, while moderate or severe ADRs are relatively rare, suggesting that enhanced CT examination with non-ionic iodinated contrast media is highly safe, and severe adverse events will seldom occur under appropriate care. The study included 109,255 patients enrolled in various types of enhanced CT examinations, which could reflect ADR conditions and regulations in Chinese population accurately and reliably.

  7. Iodine poisoning

    Science.gov (United States)

    ... Iodine is also used during the production of methamphetamine. Note: This list may not be all inclusive. ... breathing machine (ventilator) Blood and urine tests Chest x-ray EKG (electrocardiogram, or heart tracing) Fluids through a ...

  8. Radiographic, MR or ultrasound contrast media in pregnant or breast-feeding women. What are the key issues?

    International Nuclear Information System (INIS)

    Froehlich, J.M.; Kubik-Huch, Rahel A.

    2013-01-01

    The use and the safety of radiographic, MR- or ultrasound contrast media in the diagnostic work-up of pregnant or lactating patients is a frequently discussed question. As only sparse clinical data is available, a careful benefit-risk assessment must contain physico-chemical properties, preclinical data including teratogeneity and embryotoxicity, as well as maternal and foetal exposure. With consideration to the individual risks, iodinated contrast media, macrocyclic MR contrast media with increased stability or sulphur hexafluoride ultrasound contrast media may, if clinically justified, be administered in the smallest possible doses throughout pregnancy. After parental administration of an iodinated contrast medium after the 12th week of pregnancy, the neonate's thyroidal function should be checked during the first week after birth. After parental administration of iodinated, stable macrocyclic, gadolinium or ultrasound contrast media, lactation can be continued normally. In any case, contrast media should be used with caution and only if the benefits outweigh the risk. (orig.)

  9. The Multi-center Evaluation of the Accuracy of the Contrast MEdium INduced Pd/Pa RaTiO in Predicting FFR (MEMENTO-FFR) Study.

    Science.gov (United States)

    Leone, Antonio Maria; Martin-Reyes, Roberto; Baptista, Sergio B; Amabile, Nicolas; Raposo, Luis; Franco Pelaez, Juan Antonio; Trani, Carlo; Cialdella, Pio; Basile, Eloisa; Zimbardo, Giuseppe; Burzotta, Francesco; Porto, Italo; Aurigemma, Cristina; Rebuzzi, Antonio G; Faustino, Mariana; Niccoli, Giampaolo; Abreu, Pedro F; Slama, Michel S; Spagnoli, Vincent; Telleria Arrieta, Miren; Amat Santos, Ignacio J; de la Torre Hernandez, Jose M; Lopez Palop, Ramon; Crea, Filippo

    2016-08-20

    Adenosine administration is needed for the achievement of maximal hyperaemia fractional flow reserve (FFR) assessment. The objective was to test the accuracy of Pd/Pa ratio registered during submaximal hyperaemia induced by non-ionic contrast medium (contrast FFR [cFFR]) in predicting FFR and comparing it to the performance of resting Pd/Pa in a collaborative registry of 926 patients enrolled in 10 hospitals from four European countries (Italy, Spain, France and Portugal). Resting Pd/Pa, cFFR and FFR were measured in 1,026 coronary stenoses functionally evaluated using commercially available pressure wires. cFFR was obtained after intracoronary injection of contrast medium, while FFR was measured after administration of adenosine. Resting Pd/Pa and cFFR were significantly higher than FFR (0.93±0.05 vs. 0.87±0.08 vs. 0.84±0.08, ptime and costs.

  10. Iodine in diet

    Science.gov (United States)

    Diet - iodine ... Many months of iodine deficiency in a person's diet may cause goiter or hypothyroidism . Without enough iodine, ... and older children. Getting enough iodine in the diet may prevent a form of physical and intellectual ...

  11. The use of dilute calogen[reg] as a fat density oral contrast medium in upper abdominal computed tomography, compared with the use of water and positive oral contrast media

    International Nuclear Information System (INIS)

    Ramsay, Duncan W.; Markham, Derrian H.; Morgan, Bruno; Rodgers, Peter M.; Liddicoat, Amanda J.

    2001-01-01

    AIM: Oral contrast media are commonly given prior to computed tomography (CT) examination of the upper abdomen. Although positive oral contrast media are normally used, there is increasing interest in using negative agents such as water and less commonly fat density products. The aim of this study was to compare a positive oral contrast medium, water, and a diluted emulsion of arachis oil (Calogen[reg], a fat density food supplement) for assessment of the upper abdomen. MATERIALS AND METHODS: Seventy-one patients referred for upper abdominal CT were randomized to receive either 500 ml water, 2% sodium diatrizoate or a dilute suspension of Calogen[reg]. The CT images were scored independently by three radiologists. Distension and anatomical identification was assessed for the stomach, duodenum and jejunum; with anatomical identification recorded for the pancreas, retroperitoneum, liver, gallbladder and spleen. RESULTS: Dilute Calogen[reg] produced a significant improvement (P < 0.01) in distension and anatomical visualization of the stomach and proximal duodenum. Only minimal differences were demonstrated between the three contrast media for visualization of more distal small bowel or identification of the other upper abdominal viscera. Significantly more artifacts were caused by positive contrast media than with the Calogen[reg] mixture. CONCLUSION: A dilute suspension of Calogen[reg] as an oral contrast medium is recommended when disease is suspected within the stomach or proximal duodenum. Ramsay, D.W. et al. (2001)

  12. Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Ming; Chu, Sung-Yu; Hsu, Ming-Yi [Chang Gung University, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital Linkou, College of Medicine, Taoyuan (China); Liao, Ying-Lan [National Tsing Hua University, Department of Biomedical Engineering and Environmental Sciences, Hsinchu (China); Tsai, Hui-Yu [Chang Gung University, Department of Medical Imaging and Radiological Sciences, College of Medicine, Taoyuan (China); Chang Gung University, Healthy Aging Research Center, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Sciences, Taoyuan (China)

    2014-02-15

    To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR). The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra-individual comparisons of arterial phase images using 120 kVp (standard tube voltage) and 80 kVp (low tube voltage). Low-tube-voltage imaging was performed on a 320-detector CT with IR following injection of 40 ml of contrast medium. We assessed aortic attenuation, aortic attenuation gradient, image noise, contrast-to-noise ratio (CNR), volume CT dose index (CTDI{sub vol}), and figure of merit (FOM) of image noise and CNR. Two readers assessed images for diagnostic quality, image noise, and artefacts. The low-tube-voltage protocol showed 23-31 % higher mean aortic attenuation and image noise (both P < 0.01) than the standard-tube-voltage protocol, but no significant difference in the CNR and aortic attenuation gradients. The low-tube-voltage protocol showed a 48 % reduction in CTDI{sub vol} and an 80 % increase in FOM of CNR. Subjective diagnostic quality was similar for both protocols, but low-tube-voltage images showed greater image noise (P = 0.01). Application of IR to an 80-kVp CT aortography protocol allows radiation dose and contrast medium reduction without affecting image quality. (orig.)

  13. Contrast-induced encephalopathy following cardiac catheterization.

    Science.gov (United States)

    Spina, Roberto; Simon, Neil; Markus, Romesh; Muller, David Wm; Kathir, Krishna

    2017-08-01

    To describe the epidemiology, pathophysiology, clinical presentation, and management of contrast-induced encephalopathy (CIE) following cardiac catheterization. CIE is an acute, reversible neurological disturbance directly attributable to the intra-arterial administration of iodinated contrast medium. The PubMed database was searched and all cases in the literature were retrieved and reviewed. 52 reports of CIE following cardiac catheterization were found. Encephalopathy, motor and sensory disturbances, vision disturbance, opthalmoplegia, aphasia, and seizures have been reported. Transient cortical blindness is the most commonly reported neurological syndrome, occurring in approximately 50% of cases. The putative mechanism involves disruption of the blood brain barrier and direct neuronal injury. Contrast-induced transient vasoconstriction has also been implicated. Symptoms typically appear within minutes to hours of contrast administration and resolve entirely within 24-48 hr. Risk factors may include hypertension, diabetes mellitus, renal impairment, the administration of large volumes of iodinated contrast, percutaneous coronary intervention or selective angiography of internal mammary grafts, and previous adverse reaction to iodinated contrast. Characteristic findings on cerebral imaging include cortical and sub-cortical contrast enhancement on computed tomography (CT). Imaging findings in CIE may mimic subarachnoid hemorrhage or cerebral ischemia; the Hounsfield scale on CT and the apparent diffusion coefficient on magnetic resonance imaging (MRI) are useful imaging tools in distinguishing these entities. In some cases, brain imaging is normal. Prognosis is excellent with supportive management alone. CIE tends to recur, although re-challenge with iodinated contrast without adverse effects has been documented. CIE is an important clinical entity to consider in the differential diagnosis of stroke following cardiac catheterization. Given that prognosis is

  14. Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight

    International Nuclear Information System (INIS)

    Erturk, S.M.; Ichikawa, T.; Sou, H.; Tsukamoto, T.; Motosugi, U.; Araki, T.

    2008-01-01

    Aim: To investigate the effects of contrast material injection duration on peak enhancement times and attenuation values of the aorta, main portal vein, and liver at MDCT when the dose of contrast material is adjusted to patient weight. Material and methods: Seventy-five patients were randomly assigned to one of five groups, with durations of injection of 25, 30, 35, 40, or 45 s. All patients were injected with 2 ml/kg iodine (300 mg/ml). Attenuation values and peak enhancement times for the aorta, main portal vein, and liver were determined. The relationship between patient weight and enhancement times and values, the differences regarding peak enhancement times, and the relationship between injection duration and enhancement values were investigated using Pearson correlation, analysis of variance (ANOVA), and Spearman rank correlation, respectively. Results: No significant correlations were seen between patient weight and peak enhancement times or values. Mean peak enhancement times for the aorta, main portal vein, and liver were 9-11 s, 18-22 s, and 30-34 s, respectively (p > 0.05). The correlations between injection duration and peak enhancement values were significant and negative. Conclusions: Regardless of patient weight and injection duration, peak enhancement times of aorta, main portal vein and liver were approximately 10, 20, and 30 s, respectively. The enhancement values tended to be higher for shorter injection durations

  15. Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison).

    Science.gov (United States)

    Jung, E M; Kubale, R; Jungius, K-P; Jung, W; Lenhart, M; Clevert, D-A

    2006-01-01

    To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85

  16. Drugs of abuse, cytostatic drugs and iodinated contrast media in tap water from the Madrid region (central Spain):A case study to analyse their occurrence and human health risk characterization.

    Science.gov (United States)

    Mendoza, A; Zonja, B; Mastroianni, N; Negreira, N; López de Alda, M; Pérez, S; Barceló, D; Gil, A; Valcárcel, Y

    2016-01-01

    This work analyses the presence of forty-eight emerging pollutants, including twenty-five drugs of abuse and metabolites, seventeen cytostatic drugs and six iodinated contrast media, in tap water from the Madrid Region. Analysis of the target compounds in the tap water was performed by means of (on-line or off-line) solid-phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry. A preliminary human health risk characterization was undertaken for each individual compound and for different groups of compounds with a common mechanism of action found in tap water. The results of the study showed the presence of eight out of the twenty-five drugs of abuse and metabolites analysed, namely, the cocainics cocaine and benzoylecgonine, the amphetamine-type stimulants ephedrine, 3,4-methylenedioxymethamphetamine and methamphetamine, the opioid methadone and its metabolite 2-ethylene-1,5-dimethyl-3,3-diphenylpyrrolidine and, finally caffeine at concentrations ranging from 0.11 to 502 ng L(-1). Four out of the six analysed iodinated contrast media, namely, diatrizoate, iohexol, iomeprol and iopromide, were detected in at least one sample, with concentration values varying between 0.4 and 5 ng L(-1). Cytostatic compounds were not detected in any sample. Caffeine was the substance showing the highest concentrations, up to 502 ng L(-1), mainly in the drinking water sampling point located in Madrid city. Among the other drugs of abuse, the most abundant compounds were cocaine and benzoylecgonine, detected at concentrations ranging from 0.11 to 86 ng L(-1) and from 0.11 to 53 ng L(-1), respectively. Regarding iodinated contrast media, iohexol was the most ubiquitous and abundant compound, with a frequency of detection of 100% and concentrations from 0.5 to 5.0 ng L(-1) in basically the same range in all sampling points. Taking into account the results and types of treatment applied, ozonisation plus granular activated carbon filtration appears to be

  17. Iodine Satellite

    Science.gov (United States)

    Kamhawi, Hani; Dankanich, John; Martinez, Andres; Petro, Andrew

    2015-01-01

    The Iodine Satellite (iSat) spacecraft will be the first CubeSat to demonstrate high change in velocity from a primary propulsion system by using Hall thruster technology and iodine as a propellant. The mission will demonstrate CubeSat maneuverability, including plane change, altitude change and change in its closest approach to Earth to ensure atmospheric reentry in less than 90 days. The mission is planned for launch in fall 2017. Hall thruster technology is a type of electric propulsion. Electric propulsion uses electricity, typically from solar panels, to accelerate the propellant. Electric propulsion can accelerate propellant to 10 times higher velocities than traditional chemical propulsion systems, which significantly increases fuel efficiency. To enable the success of the propulsion subsystem, iSat will also demonstrate power management and thermal control capabilities well beyond the current state-of-the-art for spacecraft of its size. This technology is a viable primary propulsion system that can be used on small satellites ranging from about 22 pounds (10 kilograms) to more than 1,000 pounds (450 kilograms). iSat's fuel efficiency is ten times greater and its propulsion per volume is 100 times greater than current cold-gas systems and three times better than the same system operating on xenon. iSat's iodine propulsion system consists of a 200 watt (W) Hall thruster, a cathode, a tank to store solid iodine, a power processing unit (PPU) and the feed system to supply the iodine. This propulsion system is based on a 200 W Hall thruster developed by Busek Co. Inc., which was previously flown using xenon as the propellant. Several improvements have been made to the original system to include a compact PPU, targeting greater than 80 percent reduction in mass and volume of conventional PPU designs. The cathode technology is planned to enable heaterless cathode conditioning, significantly increasing total system efficiency. The feed system has been designed to

  18. Intracavitary application of contrast medium in the follow-up of complicated tube-drained pleural empyema: Conventional radiography vs CT

    International Nuclear Information System (INIS)

    Duex, M.; Bischoff, H.; Schmaehl, A.; Tuengerthal, S.

    1997-01-01

    Purpose: To define the value of conventional radiography compared with CT in the follow-up of complicated, long-term tube drained pleural empyema after intracavitary application of contrast medium. Methods: 28 patients with complicated pleural empyema (stage III) and longterm tube drainage were submitted to fluoroscopy of the pleural cavity and a CT of the thorax after contrast medium had been instilled into the pleural space. Both examinations were judged by the following criteria: Number and morphology of pleural cavities, quality of drainage and accompanying thoracic disease. Results: 49 pleural cavities were diagnosed. Judgement of drainage corresponded in 79% of cases and differed 21% with proof of further not drained cavities only on CT. 4 bronchopleural fistulas were diagnosed by fluoroscopy, of which only 2 were evident on CT. Accompanying thoracic disease was reliably detected by CT only. Conclusions: Diagnosis of bronchopleural fistulas and judgement of the pleural drainage is best possible using fluoroscopy after application of contrast medium into the pleural space. CT is most accurate to detect further cavities that have not been drained, to look for concomitant thoracic disease, and to judge the morphology of the pleural cavity. Conventional radiography of the pleural space is effective and recommended to be used as a first line investigation for the follow-up of stage III empyemas. Patients in poor general condition (fever, elevated blood markers indicating inflammation) should be examined by both fluoroscopy and CT. (orig.) [de

  19. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [University of Copenhagen, Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, and Department of Diagnostic Sciences, Faculty of Health Sciences, Herlev (Denmark); Morcos, Sameh K. [University of Sheffield, Department of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom)

    2009-04-15

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) <60 ml/min undergoing contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients with moderate-to-severe renal failure received a similar IV contrast dose (40 gI). Serum creatinine (SCr) was measured at screening, baseline and 48-72 {+-} 6 h after the MDCT examination. Primary CIN outcome was an increase in SCr {>=}0.5 mg/dl ({>=}44.2 {mu}mol/l) from baseline. The CIN rates were 2.3% in the total population, 0.6% when GFR >40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  20. Nonlinear image blending for dual-energy MDCT of the abdomen: can image quality be preserved if the contrast medium dose is reduced?

    Science.gov (United States)

    Mileto, Achille; Ramirez-Giraldo, Juan Carlos; Marin, Daniele; Alfaro-Cordoba, Marcela; Eusemann, Christian D; Scribano, Emanuele; Blandino, Alfredo; Mazziotti, Silvio; Ascenti, Giorgio

    2014-10-01

    The objective of this study was to compare the image quality of a dual-energy nonlinear image blending technique at reduced load of contrast medium with a simulated 120-kVp linear blending technique at a full dose during portal venous phase MDCT of the abdomen. Forty-five patients (25 men, 20 women; mean age, 65.6 ± 9.7 [SD] years; mean body weight, 74.9 ± 12.4 kg) underwent contrast-enhanced single-phase dual-energy CT of the abdomen by a random assignment to one of three different contrast medium (iomeprol 400) dose injection protocols: 1.3, 1.0, or 0.65 mL/kg of body weight. The contrast-to-noise ratio (CNR) and noise at the portal vein, liver, aorta, and kidney were compared among the different datasets using the ANOVA. Three readers qualitatively assessed all datasets in a blinded and independent fashion. Nonlinear blended images at a 25% reduced dose allowed a significant improvement in CNR (p < 0.05 for all comparisons), compared with simulated 120-kVp linear blended images at a full dose. No statistically significant difference existed in CNR and noise between the nonlinear blended images at a 50% reduced dose and the simulated 120-kVp linear blended images at a full dose. Nonlinear blended images at a 50% reduced dose were considered in all cases to have acceptable image quality. The dual-energy nonlinear image blending technique allows reducing the dose of contrast medium up to 50% during portal venous phase imaging of the abdomen while preserving image quality.

  1. In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT

    Science.gov (United States)

    Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F.; Gao, Dong-Wei

    2012-01-01

    Purpose: To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Materials and Methods: Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Results: Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase–enhanced CT scan simultaneously in a single examination. Conclusion: Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012 PMID:22778447

  2. Practice patterns for the use of iodinated i.v. contrast media for pediatric CT studies: a survey of the Society for Pediatric Radiology.

    Science.gov (United States)

    Callahan, Michael J; Servaes, Sabah; Lee, Edward Y; Towbin, Alexander J; Westra, Sjirk J; Frush, Donald P

    2014-04-01

    There are limited data available on the use of i.v. contrast media for CT studies in the pediatric population. The purpose of this study is to determine the practice patterns of i.v. contrast media usage for pediatric CT by members of the Society for Pediatric Radiology (SPR). SPR members were surveyed regarding the use of i.v. contrast media for pediatric CT studies. Questions pertained to information required before administering i.v. contrast media, types of central catheters for injecting i.v. contrast media, injection rates based on angiocatheter size and study type, and management of i.v. contrast media extravasation. The response rate of 6% (88/1545) represented practice patterns of 26% (401/1545) of the SPR membership. Most respondents thought the following clinical information was mandatory before i.v. contrast media administration: allergy to i.v. contrast media (97%), renal insufficiency (97%), current metformin use (72%), significant allergies (61%), diabetes (54%), and asthma (52%). Most administered i.v. contrast media through nonimplanted central venous catheters (78%), implanted venous ports (78%), and peripherally inserted central catheters (72%). The most common maximum i.v. contrast media injection rates were 5.0 mL/s or greater for a 16-gauge angiocatheter, 4.0 mL/s for an 18-gauge angiocatheter, 3.0 mL/s for a 20-gauge angiocatheter, and 2.0 mL/s for a 22-gauge angiocatheter. For soft-tissue extravasation of i.v. contrast media, 95% elevate the affected extremity, 76% use ice, and 45% use heat. The results of this survey illustrate the collective opinion of a subset of SPR members relating to the use of i.v. contrast media in pediatric CT, providing guidelines for clinical histories needed before i.v. contrast media, maximum i.v. contrast injection rates for standard angiocatheters, contrast media injection rates for specific CT studies, and management of i.v. contrast media soft-tissue extravasation.

  3. Pathophysiologic effects of stable iodine used as a thyroidal blocking agent to reduce thyroid radiation exposure. Final progress report, November 1, 1976--December 31, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Becker, D.V.; Hurley, J.R.

    1977-01-01

    In order to determine whether acute administration of iodide leads to any undesirable effects in the general population, we studied a group of patients who received iodinated radiographic contrast medium in the course of routine x-ray diagnostic procedures. We were particularly interested in investigating the possibility that administration of iodine could damage thyroid follicular cells leading to release of intrathyroidal antigens such as thyroglobulin into the blood. An increase in serum thyroglobulin might, in turn, either initiate or exacerbate thyroid autoimmunity in susceptible individuals, leading to autoimmune thyroiditis. We looked for undesirable effects due to the administration of iodide in 3 ways: a possible acute toxic effect on thyroid follicular cells was investigated by determining serum thyroglobulin immediately prior to and 24 hours after injection of iodinated contrast medium; an effect on thyroid autoimmunity was investigated by determining thyroid autoantibodies immediately prior to and 3 to 6 months after injection of iodinated contrast medium; and acute and chronic effects on thyroid function were investigated by performing thyroid function tests immediately prior to, 24 hours after and 3 to 6 months after injection of iodinateed contrast medium.

  4. Pathophysiologic effects of stable iodine used as a thyroidal blocking agent to reduce thyroid radiation exposure. Final progress report, November 1, 1976--December 31, 1977

    International Nuclear Information System (INIS)

    Becker, D.V.; Hurley, J.R.

    1977-01-01

    In order to determine whether acute administration of iodide leads to any undesirable effects in the general population, we studied a group of patients who received iodinated radiographic contrast medium in the course of routine x-ray diagnostic procedures. We were particularly interested in investigating the possibility that administration of iodine could damage thyroid follicular cells leading to release of intrathyroidal antigens such as thyroglobulin into the blood. An increase in serum thyroglobulin might, in turn, either initiate or exacerbate thyroid autoimmunity in susceptible individuals, leading to autoimmune thyroiditis. We looked for undesirable effects due to the administration of iodide in 3 ways: a possible acute toxic effect on thyroid follicular cells was investigated by determining serum thyroglobulin immediately prior to and 24 hours after injection of iodinated contrast medium; an effect on thyroid autoimmunity was investigated by determining thyroid autoantibodies immediately prior to and 3 to 6 months after injection of iodinated contrast medium; and acute and chronic effects on thyroid function were investigated by performing thyroid function tests immediately prior to, 24 hours after and 3 to 6 months after injection of iodinateed contrast medium

  5. Comparative investigation of X-ray contrast medium degradation by UV/chlorine and UV/H2O2.

    Science.gov (United States)

    Kong, Xiujuan; Jiang, Jin; Ma, Jun; Yang, Yi; Pang, Suyan

    2018-02-01

    The degradation of iopamidol and diatrizoate sodium (DTZ) by UV/chlorine was carried out according to efficiency, mechanism, and oxidation products, and compared to that by UV/H 2 O 2 . The pseudo-first order rate (k') of iopamidol and DTZ was accelerated by UV/chlorine compared to that by UV and chlorine alone. k' of iopamidol and DTZ by UV/chlorine increased with increasing chlorine dosage. Both of iopamidol and DTZ could not be effectively removed by UV/H 2 O 2 compared to that by UV/chlorine. Secondary radicals (Cl 2 - and ClO) rather than primary radicals (HO and Cl) were demonstrated to be mainly responsible for the enhanced removal of iopamidol and DTZ by UV/chlorine. The oxidation products of iopamidol and DTZ resulting from UV/chlorine and UV/H 2 O 2 process were identified, and differences existed in the two systems. IO 3 - (the desired sink of I - ) was the major inorganic product in the UV/chlorine process whereas I - was the predominant inorganic product in the UV/H 2 O 2 process. The formation of chlorine-containing products during the degradation of iopamidol and DTZ by UV/chlorine was also observed. H-abstraction, additions, de-iodination were shared during the degradation of iopamidol by UV/chlorine and UV/H 2 O 2 . Neutral pH condition was preferred for the removal of iopamidol and DTZ by UV/chlorine. UV/chlorine could also be applied in real waters for the removal of iopamidol and DTZ. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Feasibility Study of Using Gemstone Spectral Imaging (GSI) and Adaptive Statistical Iterative Reconstruction (ASIR) for Reducing Radiation and Iodine Contrast Dose in Abdominal CT Patients with High BMI Values.

    Science.gov (United States)

    Zhu, Zheng; Zhao, Xin-ming; Zhao, Yan-feng; Wang, Xiao-yi; Zhou, Chun-wu

    2015-01-01

    To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values. 26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A). Another 21 patients (weight ≤ 65kg and BMI ≥ 22) were scanned with a conventional 120 kVp tube voltage for noise index (NI) of 11 with 450mgI/kg contrast material as control group (group B). GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD), signal-noise-ratio (SNR), contrast-noise-ratio (CNR) of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis. As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684). CT dose index (CTDI) values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000), respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B. The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.

  7. Feasibility Study of Using Gemstone Spectral Imaging (GSI and Adaptive Statistical Iterative Reconstruction (ASIR for Reducing Radiation and Iodine Contrast Dose in Abdominal CT Patients with High BMI Values.

    Directory of Open Access Journals (Sweden)

    Zheng Zhu

    Full Text Available To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI and adaptive statistical iterative reconstruction (ASIR for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values.26 patients (weight > 65kg and BMI ≥ 22 underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A. Another 21 patients (weight ≤ 65kg and BMI ≥ 22 were scanned with a conventional 120 kVp tube voltage for noise index (NI of 11 with 450mgI/kg contrast material as control group (group B. GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD, signal-noise-ratio (SNR, contrast-noise-ratio (CNR of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis.As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684. CT dose index (CTDI values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000, respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B.The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.

  8. Nefroproteção relacionada ao uso de meio de contraste iodado: atenção de enfermagem Nefroprotección relacionada al uso de medio de contraste yodado: atención de enfermería Nephroprotection associated with the use of iodinated contrast: nursing care

    Directory of Open Access Journals (Sweden)

    Rosana Pires Russo Bianco

    2008-01-01

    : This review was performed using books, serials, and the databases MEDLINE, SciELO, LILACS, published the 1997 a 2007. RESULTS: Since they are directly involved in the CIN administration procedure, the nursing staff plays a relevant role in patients' nephroprotection by trying to identify risk factors and implementing protocols to prevent complications related to the use of iodinated contrast media. CONCLUSION: Knowing itself that the ways of contrast can generate different types of adverse reactions in the patients, the nurse becomes important to be qualified scientific, to recognize these injury and thus to implement pertinent, efficient interventions and that they minimize the complications.

  9. Role of medium heterogeneity and viscosity contrast in miscible flow regimes and mixing zone growth: A computational pore-scale approach

    Science.gov (United States)

    Afshari, Saied; Hejazi, S. Hossein; Kantzas, Apostolos

    2018-05-01

    Miscible displacement of fluids in porous media is often characterized by the scaling of the mixing zone length with displacement time. Depending on the viscosity contrast of fluids, the scaling law varies between the square root relationship, a sign for dispersive transport regime during stable displacement, and the linear relationship, which represents the viscous fingering regime during an unstable displacement. The presence of heterogeneities in a porous medium significantly affects the scaling behavior of the mixing length as it interacts with the viscosity contrast to control the mixing of fluids in the pore space. In this study, the dynamics of the flow and transport during both unit and adverse viscosity ratio miscible displacements are investigated in heterogeneous packings of circular grains using pore-scale numerical simulations. The pore-scale heterogeneity level is characterized by the variations of the grain diameter and velocity field. The growth of mixing length is employed to identify the nature of the miscible transport regime at different viscosity ratios and heterogeneity levels. It is shown that as the viscosity ratio increases to higher adverse values, the scaling law of mixing length gradually shifts from dispersive to fingering nature up to a certain viscosity ratio and remains almost the same afterwards. In heterogeneous media, the mixing length scaling law is observed to be generally governed by the variations of the velocity field rather than the grain size. Furthermore, the normalization of mixing length temporal plots with respect to the governing parameters of viscosity ratio, heterogeneity, medium length, and medium aspect ratio is performed. The results indicate that mixing length scales exponentially with log-viscosity ratio and grain size standard deviation while the impact of aspect ratio is insignificant. For stable flows, mixing length scales with the square root of medium length, whereas it changes linearly with length during

  10. Evaluation of Tumor Angiogenesis with a Second-Generation US Contrast Medium in a Rat Breast Tumor Model

    International Nuclear Information System (INIS)

    Ko, Eun Young; Lee, Sang Hoon; Kim, Hak Hee; Kim, Sung Moon; Shin, Myung Jin; Kim, Nam Kug; Gong, Gyung Yub

    2008-01-01

    Tumor angiogenesis is an important factor for tumor growth, treatment response and prognosis. Noninvasive imaging methods for the evaluation of tumor angiogenesis have been studied, but a method for the quantification of tumor angiogenesis has not been established. This study was designed to evaluate tumor angiogenesis in a rat breast tumor model by the use of a contrast enhanced ultrasound (US) examination with a second-generation US contrast agent. The alkylating agent 19N-ethyl-N-nitrosourea (ENU) was injected into the intraperitoneal cavity of 30-day-old female Sprague-Dawley rats. Three to four months later, breast tumors were detected along the mammary lines of the rats. A total of 17 breast tumors larger than 1 cm in nine rats were evaluated by gray-scale US, color Doppler US and contrast-enhanced US using SonoVue. The results were recorded as digital video images; time-intensity curves and hemodynamic parameters were analyzed. Pathological breast tumor specimens were obtained just after the US examinations. The tumor specimens were stained with hematoxylin and eosin (H and E) and the expression of CD31, an endothelial cell marker, was determined by immunohistochemical staining. We also evaluated the pathological diagnosis of the tumors and the microvessel density (MVD). Spearman's correlation and the Kruskal-Wallis test were used for the analysis. The pathological diagnoses were 11 invasive ductal carcinomas and six benign intraductal epithelial proliferations. The MVD did not correlate with the pathological diagnosis. However, blood volume (BV) showed a statistically significant correlation with MVD (Spearman's correlation, p < 0.05). Contrast-enhanced US using a second-generation US contrast material was useful for the evaluation of tumor angiogenesis of breast tumors in the rat

  11. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    Energy Technology Data Exchange (ETDEWEB)

    Felmly, Lloyd M. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiothoracic Surgery, Department of Surgery, Charleston, SC (United States); De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2017-05-15

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m{sup 2} vs. 28.1±5.4 kg/m{sup 2}, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  12. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    International Nuclear Information System (INIS)

    Felmly, Lloyd M.; De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D.; Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R.; Mangold, Stefanie; Vogl, Thomas J.; Wichmann, Julian L.

    2017-01-01

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m 2 vs. 28.1±5.4 kg/m 2 , P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  13. Preparation of iodine-125-labeled iothalamate for renal clearance measurements

    International Nuclear Information System (INIS)

    Rao, S.A.; Herold, T.J.; Dewanjee, M.K.

    1983-01-01

    Iothalamate, a derivative of benzoic acid, is used as a contrast medium for renal function studies, particularly for measurement of glomerular filtration rate. Its chemical composition and clearance properties are similar to those of diatrizoate. The structural differences between these groups of iodinated benzoic acid derivatives are dependent on the groups attached at the 3- and 5-positions of 2,4,6-tri-iodobenzoic acid. The renal clearance of sodium iothalamate in humans closely approximates that of inulin, and it is used as a replacement for inulin in determining glomerular filtration rate. /sup 125/I-labeled iothalamate sodium can be prepared by the exchange-labeling method at pH 4.0. Iothalamate must first be isolated from the contrast medium preparation and purified before radioiodination. After radioiodination, the product is purified by means of precipitation and is then converted to the sodium salt

  14. Barium sulfate aspiration: Severe chemical pneumonia induced by a massive reflux of contrast medium during small bowel barium enema.

    Science.gov (United States)

    Zhang, Lin; Yang, Yi; Zhang, Ji; Zhou, Xiaowei; Dong, Hongmei; Zhou, Yiwu

    2015-08-01

    Barium contrast radiography is a conventional procedure aimed at revealing lesions of the alimentary tract using barium sulfate on X-ray irradiation. Although it is widely used in clinics, adverse effects and complications are observed, such as anaphylaxis, granuloma, fecalithes, abdomen-leaking, embolism, bacterial contamination, and aspiration. We report a case of death due to a massive barium sulfate aspiration resulted from an air-barium double contrast enema radiography. A 25-year-old female patient was hospitalized with symptoms of abdominal distention, nausea, vomiting and diarrhea for three days. A progressive respiratory distress presented only 1h after a small bowel air-barium double contrast enema. The patient died 11h later. The result of autopsy revealed the cause of death to be severe chemical pneumonitis induced by gastric fluid which was aspirated into her lungs. Barium sulfate is generally recognized to be chemically inert for the respiratory system, but a mixture of barium sulfate with gastric contents is fatal. Here we intend to suggest that, when determining the potential cause of death, medical examiners should consider a patient's status quo as well as the possible adverse effects and complications caused by the barium sulfate preparation during gastrointestinal radiography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Ultrastructural study on the effects of retrograde infusion of water-soluble contrast medium the rabbit submandibular gland

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Park, Tae Won

    1987-01-01

    The author observed the effects of retrograde infusion of water soluble contrast media (Telebrix 30) on the rabbit submandibular glands and compared the effects of different degrees of filling. 26 rabbit were divided into 2 group of 1 2 each as experimental and 1 group of 2 as normal controls. One experimental group was filed with 0.2 ml and the other with 0.4 ml. Right submandibular gland of each rabbit was infused with contrast media and left one with physiologic saline as a ex perimental control, at a constant rate of 0.12 ml/min. Using an infusion pump via the main excretory duct. Immediately after the inclusion of contrast media, oblique lateral radiographs of the glands were made with occlusal film in order to confirm the glandular filling. The rabbit were sacrificed after varying periods (1, 8, 24 hours and 3, 6, 10 days) and the tissues were prepared for light and electron microscopic examination. The results were as follows: 1. In glands filled with 0.2 ml contrast media, the initial changes were a few vacuole formation in the acini and slight dilation of the intralobular duct. The moderately severe changes such as vacuole formation in the acini, the abnormal substructure within the secretory granule, dilation of acinar and intercalated duct lumen, scalloping of striated duct lumen and inflammatory cell infiltrate were observed at 3 days. The general appearance was successively recovered, so the tissue had a normal appearance at 10 days. 2. In glands filled with 0.4 ml contrast media, the most prominent alterations such as severe acinar atrophy, decreased number of secretory granules, proliferation of connective tissue stroma and pronounced inflammatory cell infiltrates appeared at 6 days. Although the general appearance returned to be almost normal at 10 days, acinar cells showed some atrophy and decreased secretory granules. 3. In glands subjected to 0.4 ml infusion, the alterations were more severe and recovery was slower than those seen in the glands

  16. Prevalence of latent and manifest hyperthyroidism in an iodine-deficient area: non-selected patient population admitted for CT studies with iodine-containing contrast agents; Praevalenz der latenten und manifesten Hyperthyreose in einem Jodmangelgebiet: Erhebung an einem nichtselektionierten Patientenkollektiv vor Durchfuehrung einer Computertomographie mit jodhaltigem Kontrastmittel

    Energy Technology Data Exchange (ETDEWEB)

    Saam, T. [Universitaetsklinikum Heidelberg, Abt. Radiodiagnostik, Heidelberg (Germany); Univ. of Washington, Abt. Radiodiagnostik, Seattle, WA (United States); Hess, T. [Universitaetsklinikum Heidelberg, Abt. Radiodiagnostik, Heidelberg (Germany); St.-Vincenz-Krankenhaus, Abt. fuer Diagnostische und Interventionelle Radiologie, Limburg (Germany); Kasperk, C. [Universitaetsklinikum Heidelberg, Abt. Endokrinologie, Heidelberg (Germany); Kauffmann, G.W. [Universitaetsklinikum Heidelberg, Abt. Radiodiagnostik, Heidelberg (Germany); Duex, M. [Universitaetsklinikum Heidelberg, Abt. Radiodiagnostik, Heidelberg (Germany); Nordwest-Krankenhaus, Radiologisches Zentralinstitut, Frankfurt am Main (Germany)

    2005-09-01

    Purpose: to evaluate the prevalence of latent and manifest hyperthyroidism in a non-selected group of patients admitted for contrast enhanced CT studies blood samples were tested for the levels of thyroid-stimulating hormone (TSH). Material and methods: TSH blood levels were obtained in 548 consecutive patients who were scheduled for contrast-enhanced (Iopromide; 300 mg iodine/ml) CT scanning. In case of TSH levels < 0.4 mU/l, blood samples were also tested for triiodothyronine (T3) and tetraiodothyronine (T4) blood levels, and treatment with Irenat {sup registered} (sodium perchlorate) was commenced before scanning. In case of TSH levels < 0.1 mU/l, CT scanning was not performed but further evaluation of the thyroid function was initiated. Results: TSH blood levels ranged from 0.4 to 7.5 mU/l in 512 patients, and 36 patients (6.6%) had TSH blood levels < 0.4 mU/l and 9 patients blood levels < 0.1 mU/l, with 32 of those patients (5.8%) having regular T3 and T4 blood levels consistent with latent hyperthyroidism. In 4 patients (0.8%), T3 or T4 blood levels were increased consistent with manifest hyperthyroidism. Conclusion: in South Germany, the prevalence of latent or manifest hyperthyroidism in a non-selected patient group is high. Therefore TSH blood levels should be obtained prior to contrast-enhanced CT studies. (orig.)

  17. 3D CT cerebral angiography technique using a 320-detector machine with a time–density curve and low contrast medium volume: Comparison with fixed time delay technique

    International Nuclear Information System (INIS)

    Das, K.; Biswas, S.; Roughley, S.; Bhojak, M.; Niven, S.

    2014-01-01

    Aim: To describe a cerebral computed tomography angiography (CTA) technique using a 320-detector CT machine and a small contrast medium volume (35 ml, 15 ml for test bolus). Also, to compare the quality of these images with that of the images acquired using a larger contrast medium volume (90 or 120 ml) and a fixed time delay (FTD) of 18 s using a 16-detector CT machine. Materials and methods: Cerebral CTA images were acquired using a 320-detector machine by synchronizing the scanning time with the time of peak enhancement as determined from the time–density curve (TDC) using a test bolus dose. The quality of CTA images acquired using this technique was compared with that obtained using a FTD of 18 s (by 16-detector CT), retrospectively. Average densities in four different intracranial arteries, overall opacification of arteries, and the degree of venous contamination were graded and compared. Results: Thirty-eight patients were scanned using the TDC technique and 40 patients using the FTD technique. The arterial densities achieved by the TDC technique were higher (significant for supraclinoid and basilar arteries, p < 0.05). The proportion of images deemed as having “good” arterial opacification was 95% for TDC and 90% for FTD. The degree of venous contamination was significantly higher in images produced by the FTD technique (p < 0.001%). Conclusion: Good diagnostic quality CTA images with significant reduction of venous contamination can be achieved with a low contrast medium dose using a 320-detector machine by coupling the time of data acquisition with the time of peak enhancement

  18. Pre-Interventional Kynurenine Predicts Medium-Term Outcome after Contrast Media Exposure Due to Coronary Angiography.

    Science.gov (United States)

    Reichetzeder, Christoph; Heunisch, Fabian; Einem, Gina von; Tsuprykov, Oleg; Kellner, Karl-Heinz; Dschietzig, Thomas; Kretschmer, Axel; Hocher, Berthold

    2017-01-01

    Contrast induced acute kidney injury (CI-AKI) remains a serious complication of contrast media enhanced procedures like coronary angiography. There is still a lack of established biomarkers that help to identify patients at high risk for short and long-term complications. The aim of the current study was to evaluate plasma kynurenine as a predictive biomarker for CI-AKI and long-term complications, measured by the combined endpoint "major adverse kidney events" (MAKE) up to 120 days after CM application. In this prospective cohort study 245 patients undergoing coronary angiography were analyzed. Blood samples were obtained at baseline, 24h and 48h after contrast media (CM) application to diagnose CI-AKI. Patients were followed for 120 days for adverse clinical events including death, the need for dialysis, and a doubling of plasma creatinine. Occurrence of any of these events was summarized in the combined endpoint MAKE. Preinterventional plasma kynurenine was not associated with CI-AKI. Patients who later developed MAKE displayed significantly increased preinterventional plasma kynurenine levels (p<0.0001). ROC analysis revealed that preinterventional kynurenine is highly predictive for MAKE (AUC=0.838; p<0.0001). The optimal cutoff was found at ≥3.5 µmol/L Using this cutoff, the Kaplan-Meier estimator demonstrated that concentrations of plasma kynurenine ≥3.5 µmol/L were significantly associated with a higher prevalence of MAKE until follow up (p<0.0001). This association remained significant in multivariate Cox regression models adjusted for relevant factors of long-term renal outcome. Preinterventional plasma kynurenine might serve as a highly predictive biomarker for MAKE up to 120 days after coronary angiography. © 2017 The Author(s). Published by S. Karger AG, Basel.

  19. Pre-Interventional Kynurenine Predicts Medium-Term Outcome after Contrast Media Exposure Due to Coronary Angiography

    Directory of Open Access Journals (Sweden)

    Christoph Reichetzeder

    2017-05-01

    Full Text Available Background/Aims: Contrast induced acute kidney injury (CI-AKI remains a serious complication of contrast media enhanced procedures like coronary angiography. There is still a lack of established biomarkers that help to identify patients at high risk for short and long-term complications. The aim of the current study was to evaluate plasma kynurenine as a predictive biomarker for CI-AKI and long-term complications, measured by the combined endpoint "major adverse kidney events" (MAKE up to 120 days after CM application. Methods: In this prospective cohort study 245 patients undergoing coronary angiography were analyzed. Blood samples were obtained at baseline, 24h and 48h after contrast media (CM application to diagnose CI-AKI. Patients were followed for 120 days for adverse clinical events including death, the need for dialysis, and a doubling of plasma creatinine. Occurrence of any of these events was summarized in the combined endpoint MAKE. Results: Preinterventional plasma kynurenine was not associated with CI-AKI. Patients who later developed MAKE displayed significantly increased preinterventional plasma kynurenine levels (p<0.0001. ROC analysis revealed that preinterventional kynurenine is highly predictive for MAKE (AUC=0.838; p<0.0001. The optimal cutoff was found at ≥3.5 µmol/L Using this cutoff, the Kaplan-Meier estimator demonstrated that concentrations of plasma kynurenine ≥3.5 µmol/L were significantly associated with a higher prevalence of MAKE until follow up (p<0.0001. This association remained significant in multivariate Cox regression models adjusted for relevant factors of long-term renal outcome. Conclusion: Preinterventional plasma kynurenine might serve as a highly predictive biomarker for MAKE up to 120 days after coronary angiography.

  20. Myelography in achondroplasia: value of a lateral C1-2 puncture and non-ionic, water-soluble contrast medium

    International Nuclear Information System (INIS)

    Suss, R.A.; Udvarhelyi, G.B.; Wang, H.; Kumar, A.J.; Zinreich, S.J.; Rosenbaum, A.E.

    1983-01-01

    Because of technical difficulties and diagnostic limitations encountered with other myelographic techniques in patients with achondroplasia, the authors employed a lateral C1-2 puncture and non-ionic, water-soluble contrast medium in 18 achondroplastic patients with spinal compression (21 procedures). This technique proved most appropriate for identifying the upper limit of degenerative osteophytes causing exacerbation of congenital spinal stenosis, which is crucial in planning decompressive surgery. A potentially important additional finding was the presence of degenerative lower cervical spine disease in the majority of patients. There were no serious complications. The authors recommend this technique as safe and effective in achondroplastic patients with severe congenital spinal stenosis

  1. An intravenously injectable emulsified iodinated oil contrast agent for liver CT. Experimental study of lipiodol emulsion emulsified by lecithin (LEL38) in rabbits

    International Nuclear Information System (INIS)

    Kamei, Tsuyoshi

    1994-01-01

    LEL38 (lipiodol emulsion emulsified by lecithin 38 mgI/ml, mean diameter 200 nm) is a new intravenously injectable oil contrast agent for liver CT. The aim of this report was to evaluate its ability to enhance contrast in the liver of 46 rabbits with regard to the correlation of density with time at an injected dose of 76 mgI/kg (before to 120 minutes after), the correlation of density with dose (0-760 mgI/kg) and the detectability of liver mass. The time-density correlation of LEL38 in the liver, that is, peak density, was achieved after 30 minutes, and it was elevated to 20.9 H. U. Thereafter, it decreased slowly. In the blood vessels, it reached a sharp peak after immediately being elevated to 14. 7 H. U. Thereafter detectability decreased quickly. The maximum difference in density between liver and blood vessels was 34 H. U. after 60 minutes. The dose-density correlation in the liver and blood vessels was linear. Tumors were detected as clear areas of low density. The minimal detectability was about 3 mm. LEL38 may be an effective contrast agent for screening CT studies of liver disease. (author)

  2. Use of postmortem coronary computed tomography angiography with water-insoluble contrast medium to detect stenosis of the left anterior descending artery in a case of sudden death.

    Science.gov (United States)

    Takahashi, Yoichiro; Sano, Rie; Takahashi, Keiko; Kominato, Yoshihiko; Takei, Hiroyuki; Kobayashi, Susumu; Shimada, Takehiro; Tokue, Hiroyuki; Awata, Sachiko; Hirasawa, Satoshi

    2016-03-01

    A 40-year-old man was found dead on a sidewalk in an expressway parking area one hour after he had entered the area on a motorcycle. A medicolegal autopsy was performed to reveal the cause of this sudden and unexpected death. Postmortem coronary CT angiography after introduction of 5% gelatin-barium emulsion as a radiopaque contrast medium into the heart demonstrated a significant arterial luminal filling defect in the left anterior descending (LAD) coronary artery. Macroscopic and microscopic examinations revealed that a thrombus had become deposited on ruptured plaque within the LAD artery, and that a small amount of the contrast medium was present between the thrombus and the vessel endothelium. These histological findings were consistent with incomplete occlusion of the LAD artery in the 3D reconstructed image. The cause of death in this case was definitively determined to be ischemic heart disease. Postmortem angiography played a role in screening of a vascular lesion that was subsequently verified by histology to have been responsible for sudden and unexpected death. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. SU-E-T-56: Brain Metastasis Treatment Plans for Contrast-Enhanced Synchrotron Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Obeid, L; Adam, J [Grenoble Institut des Neurosciences, La Tronche, Rhone-Alpes (France); Tessier, A [Centre Hospitalier Universitaire, La Tronche, Rhone-Alpes (France); Vautrin, M; Benkebil, M [DOSIsoft, Cachan, Ile de France (France); Sihanath, R [Centre Hospitalier Universitaire, La Tronche, Rhone- Alpes (France)

    2014-06-01

    Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The aim of this study is to compare dynamic stereotactic arc-therapy and iodineenhanced SSRT. Methods: Five patients bearing brain metastasis received a standard helical 3D-scan without iodine. A second scan was acquired 13 min after an 80 g iodine infusion. Two SSRT treatment plans (with/without iodine) were performed for each patient using a dedicated Monte Carlo (MC) treatment planning system (TPS) based on the ISOgray TPS. Ten coplanar beams (6×6 cm2, shaped with collimator) were simulated. MC statistical error objective was less than 5% in the 50% isodose. The dynamic arc-therapy plan was achieved on the Iplan Brainlab TPS. The treatment plan validation criteria were fixed such that 100% of the prescribed dose is delivered at the beam isocentre and the 70% isodose contains the whole target volume. The comparison elements were the 70% isodose volume, the average and maximum doses delivered to organs at risk (OAR): brainstem, optical nerves, chiasma, eyes, skull bone and healthy brain parenchyma. Results: The stereotactic dynamic arc-therapy remains the best technique in terms of dose conformation. Iodine-enhanced SSRT presents similar performances to dynamic arc-therapy with increased brainstem and brain parenchyma sparing. One disadvantage of SSRT is the high dose to the skull bone. Iodine accumulation in metastasis may increase the dose by 20–30%, allowing a normal tissue sparing effect at constant prescribed dose. Treatment without any iodine enhancement (medium-energy stereotactic radiotherapy) is not relevant with degraded HDVs (brain, parenchyma and skull bone) comparing to stereotactic dynamic arc-therapy. Conclusion: Iodine-enhanced SSRT exhibits a good potential for brain metastasis treatment regarding the dose distribution and OAR criteria.

  4. Feasibility of low-dose contrast medium high pitch CT angiography for the combined evaluation of coronary, head and neck arteries.

    Directory of Open Access Journals (Sweden)

    Zhiwei Wang

    Full Text Available PURPOSE: To evaluate the image quality and radiation dose of combined heart, head, and neck CT angiography (CTA using prospectively electrocardiography (ECG-triggered high-pitch spiral scan protocol, compared with single coronary CTA. MATERIALS AND METHODS: 151 consecutive patients were prospectively included and randomly divided into three groups. Group 1 (n = 47 underwent combined heart, neck, and head CTA using prospectively ECG-triggered high-pitch spiral (Flash scan protocol with a single-phase intravenous injection of iodinated contrast and saline flush; Group 2 (n = 51 underwent single coronary CTA with Flash scan protocol; and Group 3 (n = 53 underwent single coronary CTA with prospective sequence scan protocol. All patients were examined on a dual source CT (Definition FLASH. The image quality was determined for each CT study. RESULTS: Patients of scanning protocol Group 1, 2, and 3 showed no significant differences in age, sex, heart rates, and BMI. Evaluation of coronary artery image quality showed comparable results in the three scanning protocol groups on a per patient-based analysis. In group 1, image quality was found to be sufficient to be diagnostic in all arterial segments of carotid arteries. The mean dose-length product (DLP for group 1 was 256.3±24.5 mGy×cm and was significantly higher in comparison with group 2 (93.4±19.9 mGy×cm; p < 0.001. However, there was no significant difference of DLP between group 1 and group 3 (254.1±69.9 mGy×cm. CONCLUSIONS: The combined heart, neck, and head arteries scan using prospectively electrocardiography (ECG-triggered high-pitch spiral scan protocol in 1 single examination resulted in an excellent opacification of the aorta, the carotid arteries, and the coronary arteries and provided a good image quality with low radiation dose.

  5. Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Minwen, E-mail: zhengmw2007@163.com; Liu, Ying, E-mail: yingyinglyly@126.com; Wei, Mengqi, E-mail: weimengqi2008@163.com; Wu, Yongjie, E-mail: wu18291988526@163.com; Zhao, Hongliang, E-mail: zhaohl1980@163.com; Li, Jian, E-mail: xjyylj@yeah.net

    2014-02-15

    Objectives: To assess the impact of low-concentration contrast medium on vascular enhancement, image quality and radiation dose of coronary CT angiography (cCTA) by using a combination of iterative reconstruction (IR) and low-tube-voltage technique. Materials and methods: One hundred patients were prospectively randomized to two types of contrast medium and underwent prospective electrocardiogram-triggering cCTA (Definition Flash, Siemens Healthcare; collimation: 128 mm × 0.6 mm; tube current: 300 mA s). Fifty patients received Iopromide 370 were scanned using the conventional tube setting (100 kVp or 120 kVp if BMI ≥ 25 kg/m{sup 2}) and reconstructed with filtered back projection (FBP). Fifty patients received Iodixanol 270 were scanned using the low-tube-voltage (80 kVp or 100 kVp if BMI ≥ 25 kg/m{sup 2}) technique and reconstructed with IR. CT attenuation was measured in coronary artery and other anatomical regions. Noise, image quality and radiation dose were compared. Results: Compared with two Iopromide 370 subgroups, Iomeprol 270 subgroups showed no significant difference in CT attenuation (576.63 ± 95.50 vs. 569.51 ± 118.93 for BMI < 25 kg/m{sup 2}, p = 0.647 and 394.19 ± 68.09 vs. 383.72 ± 63.11 for BMI ≥ 25 kg/m{sup 2}, p = 0.212), noise (in various anatomical regions of interest) and image quality (3.5 vs. 4.0, p = 0.13), but significantly (0.41 ± 0.17 vs. 0.94 ± 0.45 for BMI < 25 kg/m{sup 2}, p < 0.001 and 1.14 ± 0.24 vs. 2.37 ± 0.69 for BMI ≥ 25 kg/m{sup 2}, p < 0.001) lower radiation dose, which reflects dose saving of 56.4% and 51.9%, respectively. Conclusions: Combined IR with low-tube-voltage technique, a low-concentration contrast medium of 270 mg I/ml can still maintain the contrast enhancement without impairing image quality, as well as significantly lower the radiation dose.

  6. Iodine and Pregnancy

    OpenAIRE

    Yarrington, Christina; Pearce, Elizabeth N.

    2011-01-01

    Iodine is a necessary element for the production of thyroid hormone. We will review the impact of dietary iodine status on thyroid function in pregnancy. We will discuss iodine metabolism, homeostasis, and nutritional recommendations for pregnancy. We will also discuss the possible effects of environmental contaminants on iodine utilization in pregnant women.

  7. Iodine intake in Denmark

    International Nuclear Information System (INIS)

    Pedersen, K.M.; Noehr, S.B.; Laurberg, P.

    1997-01-01

    Iodine deficiency with a high frequency of goitre and, in severely affected areas, cretinism is common in some areas of the world. In Denmark the iodine intake as evaluated by urinary iodine excretion has been at a stable low level for many years, except for the part of the population now taking iodine supplementation as part of vitamin/mineral preparations. The iodine intake is lowest in the western part to the country where an epidemiological study of elderly subjects has demonstrated a high frequency of goitre and hyperthyroidism in women. This supports the suggestion of a controlled moderate increase in iodine intake via an iodine supplementation program. (au) 40 refs

  8. Evaluation of the equine digital flexor tendon sheath using diagnostic ultrasound and contrast radiography

    International Nuclear Information System (INIS)

    Redding, W.R.

    1994-01-01

    This study was designed to evaluate the normal anatomy of the digital flexor tendon sheath using contrast radiography and diagnostic ultrasound. Iodinated contrast medium was injected into eight cadaver limbs and the limbs immediately frozen. Lateromedial and dorsopalmar/plantar radiographs were made. These limps were then cut transversely and proximal to distal radiographs of each slab were made. This cross sectional contrast methodology allowed the visualization of the relative size and shape of the superficial and deep digital flexor tendons as well as the potential space taken by effusions of the digital flexor tendon sheath. The second part of the study used twelve live animals with normal digital flexor tendon sheaths. Ultrasonographic measurement of the structures of the digital flexor tendon sheath at each level were compiled. This documented the ability of diagnostic ultrasound to image: 1) the superficial and deep digital flexor tendons, 2) the proximal and distal ring of the manica flexoria, 3) the straight and oblique sesamoidean ligaments, and 4) the mesotendinous attachments to the superficial and deep flexor tendons. Iodinated contrast medium was then injected into the digital flexor tendon sheath and the ultrasonography repeated. These images were compared with those obtained from contrast radiography and prosections of twenty normal limbs. The iodinated contrast medium enhanced sonographic imaging of the structures of the digital tendon sheath, particularly the abaxial borders of the superficial digital flexor tendon branches and the mesotendinous attachments to the superficial and deep digital flexor tendons

  9. Iodine intake in Ireland

    International Nuclear Information System (INIS)

    Smith, P.P.A.; Hetherton, A.M.; O'Carroll, D.; Smith, D.F.; O'Halloran, M.J.; O'Donovan, D.K.

    1988-01-01

    A study of urinary iodine excretion and thyroid gland uptake of radioactive iodine 131 I was undertaken in the Dublin area with a view to providing data on the current iodine status in Ireland. A mean urinary iodine excretion of 118±82μg/gram creatinine (Median 96) obtained from 821 subjects attending general hospital outpatient clinics in the Dublin area in 1987, while excluding severe iodine deficiency in this particular cohort, obscured the fact that 250 (30%) had iodine excretion values ≤70 μ/g creatinine, a value approximating to the minimum daily iodine requirement. The results provide sufficient evidence of sporadic iodine deficiency to justify a more widespread study of the iodine status of the Irish population with a view to making recommendations on the possible need for iodine prophylaxis

  10. Iodine based radiopacity of experimental blood clots for testing of mechanical thrombectomy devices

    International Nuclear Information System (INIS)

    Luo, Zhong Hua; Chung, Alex; Choi, Gibok; Lin, Yih Huie; Pang, Huajin; Uchida, Barry T.; Pavcnik, Dusan; Jeromel, Miran; Keller, Frederick S.; Rösch, Josef

    2013-01-01

    Barium sulfate powder used for radiopacity of experimental blood clots (EBCs) for testing mechanical thrombectomy devices (MTD) has negative effects on EBCs mechanical properties. In vitro and in vivo exploration was performed to determine if the iodine based contrast medium will have less negative effects on the EBCs than barium. Fresh blood from 2 swine was used to create fibrinogen enhanced and thrombin initiated EBC in tubes. Iodine radiopacity was achieved by mixing the blood with 65% Iohexol or by soaking the EBCs for 2 or 24 hours in Iohexol. The EBCs opacified with barium served as controls. In vitro study: The EBCs were subjected to four tests, manual elongation, catheter injection, radiopacity and contrast wash out tests. In vivo study: The common carotid arteries of 2 swine were embolized by either barium EBC or EBC soaked for 24 hours in Iohexol. The duration of radiopacity of the different EBCs was compared. The EBCs opacified with Iohexol initially had higher radiopacity than the barium opacified EBCs. However, their opacity rapidly decreased with saline soaking and, particularly, after they were embolized in live animals. The mechanical properties of Iohexol opacified EBCs were inferior to barium opacified EBCs. The Iohexol mixed EBCs were less firm and elastic and half of them fragmented during catheter injection. The Iohexol soaked EBCs exhibited decreased tensile strength and elasticity compared to the barium EBCs. Compared to barium, iodine based contrast medium does not offer any advantage for opacifying EBCs

  11. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Morcos, Sameh K.

    2009-01-01

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) 40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  12. In vivo magnetic resonance imaging of atherosclerotic lesions with a newly developed Evans blue-DTPA-gadolinium contrast medium in apolipoprotein-E-deficient mice.

    Science.gov (United States)

    Yasuda, Satoshi; Ikuta, Kenjiro; Uwatoku, Toyokazu; Oi, Keiji; Abe, Kohtaro; Hyodo, Fuminori; Yoshimitsu, Kengo; Sugimura, Kohtaro; Utsumi, Hideo; Katayama, Yoshiki; Shimokawa, Hiroaki

    2008-01-01

    Magnetic resonance imaging (MRI) contrast agents that specifically detect atherosclerotic plaque may be useful for the noninvasive detection of the plaque. We have recently developed a new contrast agent, Evans blue-DTPA-gadolinium (EB-DTPA-Gd), which selectively accumulates vascular lesions with endothelial removal. In this study, we examined whether EB-DTPA-Gd is also useful for in vivo imaging of atherosclerotic plaques. We used male apolipoprotein-E-deficient (ApoE-/-) mice of different ages (3, 6 and 12 months old) and age-matched male wild-type mice. After a single intravenous administration of EB-DTPA-Gd (160 microM/kg body weight), MRI T(1) signal was obtained in vivo. Increased signal intensity in the aortic wall was noted within 10-20 min after intravenous injection of EB-DTPA-Gd and was maintained for 30 min. The MRI enhancement in the aorta of ApoE-/- mice was increased in accordance with age, whereas no such enhancement was noted in wild-type mice. Histological examination demonstrated that there was a topological correlation between the site of MRI enhancement and that of atherosclerotic plaque. These results indicate that EB-DTPA-Gd is a useful MRI contrast medium for the in vivo detection of atherosclerotic plaques. Copyright (c) 2007 S. Karger AG, Basel.

  13. Visualization of endolymphatic hydrops in meniere's disease after single-dose intravenous gadolinium-based contrast medium. Timing of optimal enhancement

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Yamazaki, Masahiro; Kawai, Hisashi; Bokura, Kiminori; Sone, Michihiko; Nakashima, Tsutomu

    2012-01-01

    Visualization of endolymphatic hydrops (EH) in patients with Meniere's disease (MD) is now possible by heavily T 2 -weighted 3-dimensional fluid-attenuated inversion recovery (h T 2 W-3D-FLAIR) obtained 4 hours after intravenous (IV) administration of single dose gadolinium-based contrast medium (GBCM). Although maximum enhancement has been reported 4 hours after contrast administration in healthy volunteers, the timing of optimal enhancement in patients with MD is not reported. We investigated if that optimal timing is earlier or later than 4 hours. We evaluated 10 consecutive patients with suspected MD whom we randomly divided into 2 groups. We obtained h T 2 W-3D-FLAIR before GBCM administration and 10 min, 3.5 hours, and 4 hours after GBCM administration in Group A and before and 10 min, 4 hours, and 4.5 hours after GBCM administration in Group B. We compared signal intensity ratio (SIR) values of the perilymph and pons between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B and evaluated grades of EH at 3.5 and 4 hours in Group A and at 4 and 4.5 hours in Group B. SIR values did not differ significantly between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. However, SIR values at 4 hours were significantly higher in Group A than Group B. Grades of EH agreed between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. The optimal timing of contrast enhancement in patients with suspected MD remains unclear, but evaluation of EH may be possible from 3.5 to 4.5 hours after contrast administration. (author)

  14. Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney

    International Nuclear Information System (INIS)

    Frennby, B.; Almen, T.

    2001-01-01

    The aim of this study was to determine the relative glomerular filtration rate (GFR), i.e. the GFR of each kidney in percent of total GFR, by spiral CT. In 41 patients, who were part of a follow-up program after endoluminal stent grafting of aortic aneurysm, spiral CT with the contrast medium iohexol was used to evaluate the morphology of the aorta and kidneys. The opportunity was taken to utilize the already injected iohexol to determine the relative GFR with an extra CT sequence. In each patient two determinations were made, 6 or 12 months apart. The amount of a GFR marker accumulating in Bowman's space, tubuli, and renal pelvis within 2-3 min after i.v. injection, before any marker had left the kidney via the ureter, was defined as proportional to the GFR of that kidney. The renal accumulation of iohexol was obtained by spiral CT using 10-mm collimation and a table speed of 10 mm/s (pitch ratio 1:1) from the upper to the lower poles. The correlation coefficient between the relative GFR of each kidney determined at the first and second examination was excellent (r=0.99) with a median (range) difference of 1% (0-6%) of total GFR. The radiation dose calculated as the mean absorbed dose to the kidneys was 50 mGy and the effective dose 5 mSv. The morphology of aorta and kidneys and the relative GFR of each kidney can be determined in one session with spiral CT using iohexol as both angiographic contrast medium and as a GFR marker. It is also possible to take some plasma samples in the same session to determine iohexol concentration to calculate the body clearance of iohexol (or take plasma and urine samples to calculate the renal clearance of iohexol). (orig.)

  15. Influence of hyperosmotic agent (glycerol) in contrast enhancement

    International Nuclear Information System (INIS)

    Moriyama, Takashi; Suzuki, Shigeharu; Nakaoka, Tsutomu

    1981-01-01

    For getting a better contrast enhancement (CE) of computed tomography (CT) in brain tumors, we tried to increase the extravascular iodine concentration. A vailing ourselves of the period of returning water following intravenously administered glycerol, a drip injection of the contrast medium gave a better CE effect than the usual CE. In two benign gliomas, CE with glycerol was much better than CE without glycerol, and in two malignant gliomas and two metastatic tumors, CE with glycerol was better, but not so much better as with the benign tumors. In general, the CE effect in primary brain tumors showed a decreasing pattern, whereas in metastatic brain tumors the best time was 60 minutes after the injection of the contrast material (increasing and decreasing pattern), suggesting an increase in the extravascular iodine and a severe failure of the blood brain barrier. Two cystic malignant gliomas allowed the intravenously injected contrast medium to enter the cysts. It appears that the contrast medium passes through and/or is secreted from the wall of the cyst. (author)

  16. Radioactive Iodine Treatment for Hyperthyroidism

    Science.gov (United States)

    ... Balance › Radioactive Iodine for Hyperthyroidism Fact Sheet Radioactive Iodine for Hyperthyroidism April, 2012 Download PDFs English Zulu ... prepare for RAI or surgery. How does radioactive iodine treatment work? Iodine is important for making thyroid ...

  17. Intravenous contrast medium administration at 128 multidetector row CT pulmonary angiography: Bolus tracking versus test bolus and the implications for diagnostic quality and effective dose

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Mathias, H.; Negus, I.S.; Manghat, N.E.; Hamilton, M.C.K.

    2012-01-01

    Aim: To investigate the effects of a test bolus protocol contrast medium administration on diagnostic image quality in computed tomography pulmonary angiography (CTPA). Materials and methods: Fifty patients referred for exclusion of pulmonary embolism underwent CTPA using a test bolus protocol CTPA at 120 kVp and were compared with 50 patients undergoing CTPA using a standard bolus-tracking protocol at 120 kVp, via assessment of attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) seen in the pulmonary arteries (PAs). An additional group of 10 non-obese patients who underwent CTPA using a test bolus protocol performed at 100 kVp were also analysed. Mean effective dose was calculated from the dose–length product, using standard conversion factors. Results: The test bolus protocol showed significantly higher attenuation, SNR, and CNR in the pulmonary vasculature down to the segmental level compared to bolus-tracking CTPA (p < 0.0001). There was no significant difference in effective dose between the test bolus and bolus tracking cohorts. The additional group of test bolus CTPA examinations performed at 100 kVp had a significantly reduced effective dose in comparison to both test bolus CTPA at 120 kVp and bolus-tracking CTPA at 120 kVp (p < 0.005) yet maintained mean PA attenuation to segmental level significantly better than bolus-tracking CTPA performed at 120 kVp and comparable to the test bolus cohort performed at 120 kVp. Conclusion: Test bolus contrast administration should be used as an optimal protocol. Performing test bolus CTPA at 100 kVp, as opposed to 120 kVp, significantly reduces dose without compromising PA attenuation in non-obese subjects.

  18. Iodine and thyroid function

    Directory of Open Access Journals (Sweden)

    Hye Rim Chung

    2014-03-01

    Full Text Available Severe iodine deficiency causes hypothyroidism that results in impaired somatic growth and motor development in children. Mild and moderate iodine deficiencies cause multifocal autonomous growth of thyroid, which results in thyrotoxicosis. On the other hand, iodine excess is associated with the development of hypothyroidism and thyroid autoimmunity. In areas of iodine deficiency, a sudden increase in iodine intake is associated with transient hyperthyroidism. Recent studies demonstrated that long-term thyroid function of subjects who experienced both iodine deficiency and iodine excess during childhood tended to be abnormal despite optimization of their current iodine intake. Iodine status in the Korean Peninsula is very unique because people in the Republic of Korea have been shown to have predominantly excessive iodine levels, whereas the Democratic People's Republic of Korea is known to be an iodine-deficient area. Further research is warranted to verify the optimal ranges of iodine intake and to clarify the effects of iodine intake on thyroid disorders in the Korean Peninsula.

  19. Breast-Milk Iodine Concentrations and Iodine Levels of Infants According to the Iodine Status of the Country of Residence: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Nazeri, Pantea; Kabir, Ali; Dalili, Hosein; Mirmiran, Parvin; Azizi, Fereidoun

    2018-01-01

    Iodine, an essential micronutrient, plays a critical role in normal growth and development, especially during the first two years of life. This systematic review and meta-analysis is among the first to evaluate breast-milk iodine concentrations and infant iodine status in countries characterized by iodine sufficiency or deficiency. PubMed, Web of Science, Cochrane Library, Google Scholar, and other relevant databases, as well as reference lists of previous reviews, were searched for relevant studies published between 1986 and 2016. Mean or median breast-milk and infant urinary iodine concentrations, along with other relevant data, were extracted from eligible studies. Each study was assessed for quality and risk of bias. Of the 496 identified studies, 57 met the criteria for inclusion in the meta-analysis. The mean (confidence interval [CI]) iodine concentrations in maternal colostrum were 152.0 μg/L [CI 106.2-198.7 μg/L] and 57.8 μg/L [CI 41.4-74.1 μg/L] in iodine-sufficient and -deficient countries, respectively, indicating a significant difference between the two iodine statuses. By contrast, the corresponding values in mature milk did not differ significantly between mothers in iodine-sufficient and -deficient countries (71.5 μg/L [CI 51.0-92.0 μg/L] and 28.0 μg/L [CI -13.8 to 69.9 μg/L], respectively]. The weighted urinary iodine levels [CIs] of breast-fed infants in iodine-sufficient countries were significantly higher than those in iodine-deficient countries (164.5 μg/L [CI 116.4-212.7 μg/L] vs. 70.4 μg/L [CI 46.2-94.6 μg/L]). Similarly, a significant difference was observed in the pooled estimates of urinary iodine levels [CIs] among formula-fed infants in iodine-sufficient versus iodine-deficient countries (310.3 μg/L [CI 287.4-342.1 μg/L] vs. 38.3 μg/L [CI 23.4-53.2 μg/L]). The meta-analysis reveals that in iodine-sufficient countries, the mean iodine concentrations in colostrum and mature breast milk

  20. Effects of radiographic contrast media on the serum complement system

    International Nuclear Information System (INIS)

    Tirone, P.; Boldrini, E.

    1983-01-01

    The authors explored the activation of the complement system produced by a nonionic organic iodine compound, namely iopamidol, which is proposed as a contrast medium for radiographic examination by intravenous and intra-arterial injection. The study was conducted in vitro versus established ionic contrasts (diatrizoate, iothalamate, acetrizoate) and a nonionic compound (metrizamide). The adopted experimental model was the immunohemolytic detector system, in which the immune complex consisted of goat erythrocytes sensitized with the corresponding antibody (hemolysin), and complement (C') was supplied by guinea pig serum. All the products caused complement activation. The results show that nonionic contrast media produce less activation of the complement system than the traditional ionic contrast. Thus the us