WorldWideScience

Sample records for inverter-type x-ray equipment

  1. Comparison of x-ray output of inverter-type x-ray equipment

    International Nuclear Information System (INIS)

    Asano, Hiroshi; Miyake, Hiroyuki; Yamamoto, Keiichi

    2000-01-01

    The x-ray output of 54 inverter-type x-ray apparatuses used at 18 institutions was investigated. The reproducibility and linearity of x-ray output and variations among the x-ray equipment were evaluated using the same fluorescence meter. In addition, the x-ray apparatuses were re-measured using the same non-invasive instrument to check for variations in tube voltage, tube current, and irradiation time. The non-invasive instrument was calibrated by simultaneously obtaining measurements with an invasive instrument, employing the tube voltage and current used for the invasive instrument, and the difference was calculated. Reproducibility of x-ray output was satisfactory for all x-ray apparatuses. The coefficient of variation was 0.04 or less for irradiation times of 5 ms or longer. In 84.3% of all x-ray equipment, variation in the linearity of x-ray output was 15% or less for an irradiation time of 5 ms. However, for all the apparatuses, the figure was 50% when irradiation time was the shortest (1 to 3 ms). Variation in x-ray output increased as irradiation time decreased. Variation in x-ray output ranged between 1.8 and 2.5 compared with the maximum and minimum values, excluding those obtained at the shortest irradiation time. The relative standard deviation ranged from ±15.5% to ±21.0%. The largest variation in x-ray output was confirmed in regions irradiated for the shortest time, with smaller variations observed for longer irradiation times. The major factor responsible for variation in x-ray output in regions irradiated for 10 ms or longer, which is a relatively long irradiation time, was variation in tube current. Variation in tube current was slightly greater than 30% at maximum, with an average value of 7% compared with the preset tube current. Variations in x-ray output in regions irradiated for the shortest time were due to photographic effects related to the rise and fall times of the tube voltage waveform. Accordingly, in order to obtain constant x-ray

  2. Characteristics of specifications of transportable inverter-type X-ray equipment

    CERN Document Server

    Yamamoto, K; Asano, H

    2003-01-01

    Our X-ray systems study group measured and examined the characteristics of four transportable inverter-type X-ray equipments. X-ray tube voltage and X-ray tube current were measured with the X-ray tube voltage and the X-ray tube current measurement terminals provided with the equipment. X-ray tube voltage, irradiation time, and dose were measured with a non-invasive X-ray tube voltage-measuring device, and X-ray output was measured by fluorescence meter. The items investigated were the reproducibility and linearity of X-ray output, error of pre-set X-ray tube voltage and X-ray tube current, and X-ray tube voltage ripple percentage. The waveforms of X-ray tube voltage, the X-ray tube current, and fluorescence intensity draw were analyzed using the oscilloscope gram and a personal computer. All of the equipment had a preset error of X-ray tube voltage and X-ray tube current that met Japanese Industrial Standards (JIS) standards. The X-ray tube voltage ripple percentage of each equipment conformed to the tendenc...

  3. Characteristics of specifications of transportable inverter-type X-ray equipment

    International Nuclear Information System (INIS)

    Yamamoto, Keiichi; Miyazaki, Shigeru

    2003-01-01

    Our X-ray systems study group measured and examined the characteristics of four transportable inverter-type X-ray equipments. X-ray tube voltage and X-ray tube current were measured with the X-ray tube voltage and the X-ray tube current measurement terminals provided with the equipment. X-ray tube voltage, irradiation time, and dose were measured with a non-invasive X-ray tube voltage-measuring device, and X-ray output was measured by fluorescence meter. The items investigated were the reproducibility and linearity of X-ray output, error of pre-set X-ray tube voltage and X-ray tube current, and X-ray tube voltage ripple percentage. The waveforms of X-ray tube voltage, the X-ray tube current, and fluorescence intensity draw were analyzed using the oscilloscope gram and a personal computer. All of the equipment had a preset error of X-ray tube voltage and X-ray tube current that met Japanese Industrial Standards (JIS) standards. The X-ray tube voltage ripple percentage of each equipment conformed to the tendency to decrease when X-ray tube voltage increased. Although the X-ray output reproducibility of system A exceeded the JIS standard, the other systems were within the JIS standard. Equipment A required 40 ms for X-ray tube current to reach the target value, and there was some X-ray output loss because of a trough in X-ray tube current. Owing to the influence of the ripple in X-ray tube current, the strength of the fluorescence waveform rippled in equipments B and C. Waveform analysis could not be done by aliasing of the recording device in equipment D. The maximum X-ray tube current of transportable inverter-type X-ray equipment is as low as 10-20 mA, and the irradiation time of chest X-ray photography exceeds 0.1 sec. However, improvement of the radiophotographic technique is required for patients who cannot move their bodies or halt respiration. It is necessary to make the irradiation time of the equipments shorter for remote medical treatment. (author)

  4. Usefulness of inverter type REX-650 R/F X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Min; Oh, Jung Hwan [College of Health Sceince, Korea University, Seoul (Korea, Republic of)

    2003-06-15

    The conclusions after appraisal usefulness of Korean 30 kHz inverter type X-ray equipment which are currently used in the clinics are like those followings. The specific characters of mA, kVp, msec in the radiography keep very good accuracy and showed good waveform also under KS regulations. The output of the X-ray equipment is showed 1.7 times higher than single-phase. mA, kVp of the fluoroscopy and Sopt film exposure mA, kVp showed appropriated result under the regulations. As we consider the conversion factor of image intensifier tube used for two years, it showed pretty high results, 310 at 75 kV, and knew that the conversion factor which followed by increasing kVp increased its computations like Kim's experimentation. Those X-ray equipment showed excellent results in the appraisal while those were operating so we think that those X-ray equipment will be substitute for expensive foreign equipment in Korean domestic medical equipment in the future.

  5. Characteristics of an inverter type X-ray generator (X-ray generator for mammography)

    International Nuclear Information System (INIS)

    Miyazaki, Shigeru; Negishi, Toru; Katoh, Yoh; Abe, Shinji; Ogura, Izumi.

    1995-01-01

    Two inverter-type X-ray generators, A and B, from different manufactures were used for a dynamic mammographic study. In both X-ray generators, the percentage average error (PAE) of tube voltage (TV) and tube current (TC) was 0.2% to 1.0%; the coefficient of variation in TV, TC, and X-ray output was 0.001 to 0.03. For X-ray generator A, under the conditions of 25-40 kV and 10-400 mA, the percentage ripple of of TV was 1.4% to 5.3% for each X-ray loading; the percentage ripple of TV was greater at lower TV and larger TC. For X-ray generator B, the percentage ripple of TV depended upon the amount of X-ray loading (4.7% to 30.5%). It was greater with decreasing TV and TC; and this tendency was noticeable when TC was less than 100 mA. As regards the photographic effect, TV of X-ray generator B was lower by approximately 5 kV than that of X-ray generator A because the generator B showed a greater percentage ripple of TV. This became more evident when a molybdenum filter (0.03 mm) was used. An X-ray generator, having the most potential, may have the smallest percentage ripple of TV and coefficient of variation, probably with the highest reproducibility. However, although a generator may have good reproducibility, its X-ray output could vary widely even at the same TV and current time product, if the TV waveform fluctuates to a significant extent in response to X-ray loading. These results indicate that the percentage ripple of TV should be 3 to 4% in an X-ray generator for mammographic imaging. (N.K.)

  6. Short irradiation time characteristics of the inverter type X-ray generator

    International Nuclear Information System (INIS)

    Miyazaki, Shigeru; Hara, Takamitu; Matutani, Kazuo; Saito, Kazuhiko.

    1994-01-01

    The linearity of the X-ray output is an important factor in radiography. It is a composite of the linearities of the X-ray tube voltage, the X-ray tube current, and the exposure time. This paper focuses on the linearity of exposure time. Non-linearity of the X-ray output for short-time exposure became a problem when the three-phase X-ray generator was introduced. This paper describes the inverter-type X-ray generator, which is expected to become predominant in the future. Previously, we investigated X-ray output linearity during short-time exposure using the technique of dynamic study. In this paper, we describe the application of a digital memory and a personal computer to further investigation. The non-linearity of the X-ray output was caused by irregular waveforms of the X-ray tube voltage found at the rise time and the fall time. When the rise time was about 0.6 ms, the non-linearity was about 2%, which is negligibly small. The non-linearity due to the fall time of the X-ray tube varied greatly according to the X-ray tube current. For the minimum irradiation time of 1 ms, 4% to 27% of the non-linearity was attributable to the fall time. The main cause was the stray capacitance of the X-ray high-voltage cables. When the X-ray tube current exceeded 400 mA, the rise time was almost equal to the fall time, and the problem did not occur. Consequently, the ideal generator should have a fall time which is equal to the rise time of the X-ray tube voltage. Strictly speaking, such a generator should have rectangular waveforms. (author)

  7. X-ray equipment

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1988-01-01

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.)

  8. X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.G.B.

    1988-01-06

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.).

  9. Usefulness of Non-Invasive Measurement Tool on Performance Evaluation of Inverter Type X-ray Unit

    International Nuclear Information System (INIS)

    Kang, Se Sik; Kim, Chang Soo; Ko, Sung Jin

    2008-01-01

    As the demand of a simple and precise method increases to evaluate the performance of the inverter type x-ray unit, we evaluated the usefulness of the recently-introduced X-ray Multi-Function Test Device (moldel : Xi (unfors)-prestige). We compared the performance of X-ray Multi-Function Test Device (XMFTD) which is non-inveasive type device with the performance of Dynalyzer III that has been most widely used inveasive type measure device. X-ray output dose was increased a little in the XMFTD, but both devices were below the performance evaluation standard, 0.002 in the output reproducibility. Linearity of XMFTD were below 0.1 which means that Dynalyzer III showed more excellency in linearity. As the the accuracy of exposure factor, 1.8 and 2 tube voltage, 2.01 and 2.3 tube current were measured. The exposure time was also measured by 0.01 sec ±10%. Both devices were within the acceptance of performance evaluation standard. We proved the usefulness of X-ray Multi-Function Test Device (model: Xi (unfors)-prestige) to evaluated the performance on reproductibility and linearity of X-ray output and accuracy of exposure factor of inverter type unit.

  10. Requirements for industrial x-ray equipment

    International Nuclear Information System (INIS)

    1987-01-01

    This safety code is concerned with the protection of all individuals who may be exposed to radiation emitted by X-ray equipment operating at energies up to 1 MeV as used in industrial radiography. This code presents basic radiation safety information for the protection of personnel operating and servicing X-ray equipment and other workers and the general public in the vicinity of areas where X-ray equipment is in operation. It specifies general safety features of design, construction and functioning of X-ray equipment and facilities; describes the responsibilities of the user, operator and maintenance personnel; contains recommendations to ensure that the X-ray equipment is used and maintained in accordance with the ALARA principle; and describes a program of personnel monitoring and radiation safety surveys. ( 6 refs., 5 tabs., 4 figs.)

  11. Defects in medical X-ray equipment

    International Nuclear Information System (INIS)

    Eder, H.; Wahl, H.; Troeger, W.

    1979-01-01

    A careful estimate of the effects on the genetically significant radiation load shows that it is in the same order of magnitude as the increase in the skin dose area product. This is to say that of the genetically significant radiation dose of about 500 mJ/kg (50 mrem) per year and person due to medical X-ray diagnostics, about 75 mJ/kg (7.5 mrem) are due to serious defects in X-ray equipment. (orig.) [de

  12. [Report based on Fiscal 2000 Diagnostic X-ray Equipment Questionnaire Survey (conditions of X-ray units and similar equipment)].

    Science.gov (United States)

    Ishikawa, Mitsuo; Matsuura, Takatoshi; Okuaki, Tomoyuki; Imai, Yoshio; Tsukamoto, Atsuko; Ide, Toshinori; Shinohara, Fuminori; Miyazaki, Shigeru

    2002-08-01

    The X-ray Systems Study Group, in an attempt to determine the current status and changes in the state of X-ray equipment, reception systems, and equipment control, conducted investigational research by distributing a questionnaire survey to 400 facilities. The rate of recovery was 33%. The capacity of transformers has been increasing in spite of the three-phase 415 V decrease in the power supply of X-ray equipment. Among high-voltage generators, inverter-type X-ray equipment accounted for 81.3% of units. The ratio of the X-ray tube of a conventional rotational system to that of a high-speed rotational system was 1:3, and 54.9% had target angles of 12 . Many X-ray tubes had a heat capacity of less than 200-300 kHU. The body parts that had the shortest times on radiography were adult chest and pediatric chest. In many cases, the shortest time used was 10 msec. Facilities in which the shortest time was less than 10 msec accounted for almost half of the total number. Facilities where the radiation dose of radiography had decreased showed 1/4 of the digitalization whole. Measurement was carried out when the equipment was bought in 94.9% of facilities, and measurement when the service contract was finished was done in 77.1% of the responding facilities.

  13. Diagnostic x-ray equipment and its use

    International Nuclear Information System (INIS)

    1993-01-01

    The guide contains the requirements for the use, structure and operation of diagnostic x-ray equipment necessary to ensure the radiation safety of workers and patients. The guide is intended for the party responsible for operating the x-ray units, the staff operating, installing and maintaining x-ray examination equipment, and companies manufacturing and selling such equipment. Special requirements for mammographic and dental x-ray equipments are given in separate ST guides. (5 refs., 1 figs., 2 tabs.)

  14. Repeated pulsed x-ray emission equipment

    International Nuclear Information System (INIS)

    Terauchi, Hikaru; Iida, Satoshi

    1982-01-01

    X-ray diffraction technique has been applied to determine the spatial positions of atoms which compose a material, and it is needless to say that the technique is a fundamental means regardless of the fields of research. However, the application of X-ray diffraction to the research on physical properties has been so far limited to know the spatial positions of atoms or molecules under thermal equilibrium condition. The addition of time element to the conventional technique, that is, the analysis of material structure including the time-varying processes under non-equilibrium conditions, is considered to approach the elucidation of the essence of materials. The authors call this dynamic structural analysis. The authors have planned to analyze X-ray diffraction intensity which has the resolution of about 10 -8 s in the real time which is conjugate with energy. However, present pulsed X-ray sources are not suitable for diffraction experiment because the pulse width is too long or X-ray wavelength is too short. Accordingly, the authors have made for trial a pulsed X-ray source for diffraction experiment. Its specifications are: diode voltage (X-ray tube voltage) from 200 to 300 kV, diode current from 2 to 5 kA, pulse width of about 30ns, maximum repetition frequency 10 pps, and X-ray focus size of 2 mm diameter. One of the features of this source is the repeated generation of pulsed X-ray. This is the first trial in the world, and is indispensable to the dynamic structural analysis described above. The quality of the emitted X-ray is also written. (Wakatsuki, Y.)

  15. Traps in quality assurance of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Meier, N.; Lenzen, H.; Fiebich, M.

    1992-01-01

    With the introduction of the German industrial protocol for quality assurance of X-ray equipment, everybody using X-ray machines fell into sort of trap or found some of the procedures misleading. Vigorous discussions were held on every conceivable aspect of this and other protocols, and are still in progress. This paper points out some of the common traps and considers a new type dosimeter, which allows a definite separation of quality assurance of X-ray equipment and of processing and which can also be used in future for quality assurance of digital radiography equipment. (orig.) [de

  16. Image formation in diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Boer, J.A. den.

    1983-01-01

    This thesis deals with a physical description of the image formation in static radiographic shadow image X-ray equipment and an analysis of the optimization of such systems. For the latter criteria have been developed that take into account all relevant physical phenomena that relate to properties of the image and the radiation exposure of the patient. The discussion of image formation results in a number of relations between the X-ray system parameters on the one hand and properties of the X-ray image on the other. The three principal aspects considered are energy transfer, modulation transfer and noise. (Auth./C.F.)

  17. The IHS diagnostic X-ray equipment radiation protection program

    International Nuclear Information System (INIS)

    Knapp, A.; Byrns, G.; Suleiman, O.

    1994-01-01

    The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using the National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload

  18. [Report based on fiscal 2000 diagnostic x-ray equipment questionnaire survey(conditions of radiography)].

    Science.gov (United States)

    Ishikawa, Mitsuo; Matsuura, Takatoshi; Okuaki, Tomiyuki; Imai, Yoshio; Tsukamoto, Atsuko; Ide, Toshinori; Shinohara, Fuminori; Miyazaki, Shigeru

    2002-08-01

    X-ray equipment has seen advances in inverters and the digitalization of reception systems. The X-ray Systems Study Group, in order to examine changes in the conditions of radiography, including pediatric radiography, variations in shortest irradiation time, and standardization of the conditions of radiography, carried out investigative research using a questionnaire survey that was sent to 400 facilities. The recovery rate was 33%. In terms of the reception system, half of the general radiography systems were using computed radiography (CR). Seventy percent of respondents used an intensifying screen and film(S EF)in stomach double-contrast radiography. About 80% used digital radiography (DR) and digital subtraction angiography (DSA) in aorta abdominalis angiography. At least 70% of high-voltage generators were of the inverter type. The conditions of radiography were not greatly influenced by changes in reception systems and X-ray equipment. Many pediatric radiographies were carried out by radiological technologists. We consider it useful to conduct such survey investigations.

  19. Field size and centring for conventional X-ray equipment

    International Nuclear Information System (INIS)

    Klimpel, H.; Kreienfeld, H.; Overbeck, R.

    1989-01-01

    Since 1973, all X-ray equipment for medical applications in the Federal Republic of Germany has had to be examined according to the requirements of the German ''Rontgenverordnung'' before it is used on patients and after each essential modification of design or construction. These examinations are carried out by inspectors appointed by the authorities, e.g. TUV. The field size adjustment and the centring of the radiation beam in relation to the image reception area is checked, along with other tests. To increase quality assurance in X-ray diagnosis, since the mid-1980s X-ray equipment has also been subject to in-service inspections to an increasing extent. (author)

  20. The radioprotection inspection manual for odontologic X-rays equipment

    International Nuclear Information System (INIS)

    Almeida, C.D. de.

    1988-01-01

    The inspection manual for odontologic X-ray, using films and thermoluminescent dosemeters are showed, decreasing the time of exposition by some recommendation. Some calculations are also cited, for decrease the exposure time, for filtrating the equipment and for a radiometric survey. (C.G.C.) [pt

  1. X-ray diagnostic equipment in dentistry (review)

    International Nuclear Information System (INIS)

    Blinov, N.N.; Gubenko, M.B.; Utkin, P.M.

    2000-01-01

    The characteristics of the basic dental X-ray equipment, used in Russia, are presented. It is shown, that two main methods of roentgenography are used currently: 1) the standards study on teeth by odontology apparatuses with registration on the film; and 2) panoramic tomography through a mobile X-ray beam (orthopantomography) - the photograph of both jaws in the course of one examination with registration on the film by the intensifying screen-film combination. The least propagation is obtained by the third method for registering the X-ray image - the intraoral panoramic roentgenography. The characteristics of the foreign semiautomatic and automatic developing machines, adapters for application in the odontologic establishments of Russia are presented. Attention is also paid to the applied dental films and individual protection means. Currently there takes place the process of extending the digital radiographic equipment stock in the odontology, conditioned by the image registration means development, convenience of their application and improved quality of diagnostic information [ru

  2. Portable X-ray diffractometer equipped with XRF for archaeometry

    International Nuclear Information System (INIS)

    Uda, M.; Ishizaki, A.; Satoh, R.; Okada, K.; Nakajima, Y.; Yamashita, D.; Ohashi, K.; Sakuraba, Y.; Shimono, A.; Kojima, D.

    2005-01-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to get a diffraction pattern and a fluorescence spectrum simultaneously in air from one and the same small area on a specimen. Here, diffraction experiments were performed in two modes, i.e. an angle rotation mode and an energy dispersive mode. In the latter a diffraction pattern and a fluorescence spectrum were simultaneously recorded in a short time, 100 s or less, on one display. The diffractometer was tested in the field to confirm its performance. Targets chosen for this purpose were a bronze mirror from the Eastern Han Dynasty (25-220), and a stupa and its pedestal which are part of the painted statue of 'Tamonten holding a stupa' from the Heian Period (794-1192), enshrined in the Engyouji temple founded in 996. The bronze mirror was identified as a product of the Han Dynasty from its chemical composition and the existence of the δ phase in the Cu-Sn alloy. The stupa and its pedestal were decorated with gold powder and gold leaf, respectively. From the XRF data of the pedestal, the underlying layer of gold leaf seems to have been painted with emerald green

  3. Portable X-ray diffractometer equipped with XRF for archaeometry

    Science.gov (United States)

    Uda, M.; Ishizaki, A.; Satoh, R.; Okada, K.; Nakajima, Y.; Yamashita, D.; Ohashi, K.; Sakuraba, Y.; Shimono, A.; Kojima, D.

    2005-09-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to get a diffraction pattern and a fluorescence spectrum simultaneously in air from one and the same small area on a specimen. Here, diffraction experiments were performed in two modes, i.e. an angle rotation mode and an energy dispersive mode. In the latter a diffraction pattern and a fluorescence spectrum were simultaneously recorded in a short time, 100 s or less, on one display. The diffractometer was tested in the field to confirm its performance. Targets chosen for this purpose were a bronze mirror from the Eastern Han Dynasty (25-220), and a stupa and its pedestal which are part of the painted statue of "Tamonten holding a stupa" from the Heian Period (794-1192), enshrined in the Engyouji temple founded in 996. The bronze mirror was identified as a product of the Han Dynasty from its chemical composition and the existence of the δ phase in the Cu-Sn alloy. The stupa and its pedestal were decorated with gold powder and gold leaf, respectively. From the XRF data of the pedestal, the underlying layer of gold leaf seems to have been painted with emerald green.

  4. Usability improvement of x-ray food inspection equipment

    International Nuclear Information System (INIS)

    Ohira, Norihiro; Yamaguchi, Takashi; Ohara, Mamoru; Shimizu, Hideaki; Kamimura, Kunio; Saiki, Hideo

    2010-01-01

    To properly set up X-ray inspection equipment of foreign bodies in foods properly has become more and more complicated and time-consuming, because digital image processing used in it has more parameters for more precise inspecting. In this paper, it is reported some methods to lighten the work load of workers who set up the parameters. Using Statistical methods, we construct an auto setting lookup table for adjusting contrast and parameters of inspection algorithm. With the former we confirmed an expansion of a range of grey levels that include domain of foreign bodies in sample data. Furthermore, with we constructed in our former research, we can set automatically limit of parameters that judge input product's image to be not including foreign bodies. It is suitable for food inspection system, since users prefer severely inspecting of foreign products. (author)

  5. Order no. 286 on X-ray diagnostic equipment for medical use

    International Nuclear Information System (INIS)

    1988-05-01

    This Order amends the provisions on occupational radiation protection of the Order of 1977 on X-ray diagnostic equipment for medical use. The amendments concern X-ray examinations of women of childbearing age. In particular, it is provided that in case of pregnancy, alternate methods to X-ray examinations must be applied [fr

  6. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  7. Constancy check of beam quality in conventional diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Costa, Alessandro M.; Badin, Romulo S.; Leite, Marina S.; Caldas, Linda V.E.

    2008-01-01

    A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment

  8. Development of portable X-ray diffractometer equipped with X-ray fluorescence spectrometer and its application to archaeology

    International Nuclear Information System (INIS)

    Yamashita, Daisuke; Ishizaki, Atsushi; Uda, Masayuki

    2009-01-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to obtain a diffraction pattern and a fluorescence spectrum in air from one and the same small area of a specimen. The reason why the portable XRD with an XRF spectrometer was specially designed for archaeology may be understood from the following facts: (1) some objects exhibited in museums are not allowed to be transferred from the open air to a vacuum, even if their volumes are small; (2) some objects are very difficult to move from their original sites; (3) some parts of exhibits are extremely fragile and cannot be examined in a vacuum; and (4) information on the chemical composition and structure from the same area of an object offers a better understanding of the constitutive materials of the object. Some examples of the use of a portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer in the field are also introduced. Experimental results of Sho-kannon, Snew's mask and Tutankhamun's golden mask are shown here. (author)

  9. Evaluation of the Beam Quality of Intraoral X-ray Equipment using Intraoral Standard Films

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Sub; Kwon, Hyok Rak; Sim, Woo Hyoun; Oh, Seung Hyoun; Lee, Ji Youn; Jeon, Kug Jin; Kim, Kee Deog; Park, Chang Seo [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Yensei University, Seoul (Korea, Republic of)

    2000-09-15

    This study was to evaluate the beam quality of intraoral X-ray equipment used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. The study was done using the intraoral X-ray equipment used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Most of the HVLs of intraoral X-ray equipment were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANPAS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X-ray equipment should be managed in the planned and organized fashion.

  10. Evaluation of the Beam Quality of Intraoral X-ray Equipment using Intraoral Standard Films

    International Nuclear Information System (INIS)

    Lee, Sang Sub; Kwon, Hyok Rak; Sim, Woo Hyoun; Oh, Seung Hyoun; Lee, Ji Youn; Jeon, Kug Jin; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    This study was to evaluate the beam quality of intraoral X-ray equipment used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. The study was done using the intraoral X-ray equipment used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Most of the HVLs of intraoral X-ray equipment were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANPAS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X-ray equipment should be managed in the planned and organized fashion.

  11. Protection of the electronic components of measuring equipment from the X-ray radiation

    Science.gov (United States)

    Perez Vasquez, N. O.; Kostrin, D. K.; Uhov, A. A.

    2018-02-01

    In this work the effect of X-ray radiation on the operation of integrated circuits of the measurement equipment is discussed. The results of the calculations of a shielding system, allowing using integrated circuits with a high degree of integration in the vicinity of the X-ray source, are shown. The results of the verification of two measurement devices that was used for more than five years in the facility for training and testing of X-ray tubes are presented.

  12. Performance of X-ray equipment used for conventional radiographic examinations of children

    International Nuclear Information System (INIS)

    Lacerda, Marco A.S.; Silva, Teogenes A. da; Khoury, Helen J.

    2009-01-01

    The performance of X-ray equipment that are used for conventional X-ray examinations of children in four hospitals of Belo Horizonte, Brazil, was evaluated. The methodology proposed by the Brazilian authority for radiation protection in diagnostic radiology was adopted. The performance tests were carried out in six X-ray machines and they consisted of measurements and determination of the X-ray tube output, linearity and constancy of radiation output, accuracy and reproducibility of the exposure time and tube potential, half-value layer (HVL), light field / X-ray field alignment and accuracy of the X-ray field indicator. It was observed that only one hospital had the suitable equipment for X-ray examinations of children. Results showed that all six equipment of the four hospitals presented unsatisfactory performance in some quality control tests. Only for some combinations of the exposure parameters, generally employed in pediatric X-ray examinations, some equipment complied with the authority requirements. (author)

  13. Order No. 217 of 29 April 1977 on X-ray diagnostic equipment for medical use

    International Nuclear Information System (INIS)

    1978-01-01

    This Order was made by the National Health Service and is divided into several parts covering inter alia approval and notification of X-ray installations, conditions of liability, occupational radiation protection, construction of X-ray apparatus and its shielding and inspection of such equipment by the National Health Service. (NEA) [fr

  14. Portable energy-dispersive X-ray fluorescence equipment for the ...

    Indian Academy of Sciences (India)

    313–319. Portable energy-dispersive X-ray fluorescence equipment for the analysis of cultural heritage. ROBERTO CESAREO. Dipartimento di Matematica e Fisica, via Vienna 2, 07100 Sassari, Italy. E-mail: cesareo@uniss.it. Abstract. Energy-dispersive X-ray fluorescence (EDXRF) especially in its portable version, gen-.

  15. Code of Practice for Protection Against Ionizing Radiation Emitted from X-ray Analysis Equipment (1984)

    International Nuclear Information System (INIS)

    1984-01-01

    Appropriate working rules, safety features and monitoring requirements for general X-ray analysis units or equipment are laid down in this Code which is intended for users of such equipment. The Code advises that establishments draw up their own working procedures based on appropriate legislation and on the recommendations contained in this Code. The Code also describes the requirements for X-ray analysis equipment necessary to ensure safety. (NEA) [fr

  16. [2011 Shanghai customer satisfaction report of DSA/X-ray equipment's after-service].

    Science.gov (United States)

    Li, Bin; Qian, Jianguo; Cao, Shaoping; Zheng, Yunxin; Xu, Zitian; Wang, Lijun

    2012-11-01

    To improve the manufacturer's medical equipment after-sale service, the fifth Shanghai zone customer satisfaction survey was launched by the end of 2011. The DSA/X-ray equipment was setup as an independent category for the first time. From the survey we can show that the DSA/X-ray equipment's CSI is higher than last year, the customer satisfaction scores of preventive maintenance and service contract are lower than others, and CSI of local brand is lower than imported brand.

  17. Measurement of scattered and transmitted X-rays from intra-oral and panoramic dental X-ray equipment.

    Science.gov (United States)

    Holroyd, John Richard

    2018-04-10

    To quantify the levels of transmitted radiation arising from the use of intra-oral dental X-ray equipment and scattered radiation arising from the use of both intra-oral and panoramic X-ray equipment. Methods: Levels of scattered radiation were measured at 1 m from a phantom, using an 1800 cc ion chamber. Transmitted radiation was measured using both: i) a phantom and Dose Area Product (DAP) meter, ii) a patient and an 1800 cc ion chamber. Results: For intra-oral radiography the patient study gave a maximum transmission of 1.80% (range 0.04% to 1.80%, mean 0.26%) and the phantom study gave a maximum transmission of 6% (range 2% to 6%, mean 5%). The maximum scattered radiation, per unit DAP, was 5.5 nGy (mGy cm2)-1 at 70 kVp and a distance of 1 m. For panoramic radiography the maximum scattered radiation was 9.3 nGy (mGy cm2)-1 at 80 kVp and a distance of 1 m. Conclusions: Typical doses from scattered and transmitted radiation in modern dental practice have been measured and values are presented to enable the calculation of adequate protection measures for dental radiography rooms. Advances in knowledge: Previous studies have used a phantom and measured radiation doses at 1 m from the phantom to determine the radiation dose transmitted through a patient, whereas this study uses both patient and phantom measurements together with a large area dose meter, positioned to capture the entire X-ray beam, to ensure more realistic dose measurements can be made. © 2018 IOP Publishing Ltd.

  18. Lists A and B of X-ray equipment. As of July 1, 1984

    International Nuclear Information System (INIS)

    1984-01-01

    The lists A and B of X-ray equipment present the guidelines for X-ray device, as of December 10, 1983, that are defined in the guidelines for radiology and nuclear medicine of the Federal Association of Panel Doctors. In list A, the equipment categories of up-to-date, commercially available X-ray device are given, whereas list B classifies older equipment, both types available from manufacturers who are members of the ZVEI association. Since the categories of application II and III have been made, specifiying the equipment still in use and applicable within a given transitional period in existing medical establishments, but which may not be applied in new establishments. The list of manufacturers gives the addresses of the firms supplying the equipment described in Lists A and B, which have been compiled according to the requirements set by the Federal Association of Panel Doctors. (orig.) [de

  19. Position statement on use of hand-held portable dental X-ray equipment

    International Nuclear Information System (INIS)

    2014-06-01

    The position statement focuses on justification in the medical field, in particular on the use of hand-held portable dental x-ray equipment. It supplements another HERCA position paper, providing a general overview of the use of all hand-held portable X-ray equipment. Key Messages: - HERCA finds that the use of hand-held portable X-ray devices should be discouraged except in special circumstances. - As a general rule, these devices should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed or semi-mobile x-ray unit is impractical, e.g.: - nursing homes, residential care facilities or homes for persons with disabilities; - forensic odontology, - military operations abroad without dental facilities

  20. New methodology to measure kVp in X-rays equipment for radiodiagnosis

    International Nuclear Information System (INIS)

    Vega Ramirez, J.L.; Pela, C.A.

    1998-01-01

    The work aims to obtain through experiments a spaced out sensibilization (different optical densities) in the X-rays film by letting X-rays photons go through a metallic layer of copper with tiers with different thickness that can cover the range of kVps employed in radiological tests. Results for the kVp shown here were also compared with other equipment available in the market. Comparisons showed their similarity but have also the advantage of being cheap and viable

  1. Regulations No. 494 fo 12 September 1977 on diagnostic X-ray equipment for veterinary purposes

    International Nuclear Information System (INIS)

    1977-01-01

    These regulations lay down the requirements to be complied with for protection during work with X-ray diagnostic equipment for veterinary purposes. Operators of such equipment must follow the technical guidelines and provision is made for annual inspections to ensure that the devices meet the necessary safety standards. (NEA) [fr

  2. On the methods of determination of x-ray sources protection quality in x-ray diagnostic equipment

    International Nuclear Information System (INIS)

    Vladimirov, L.V.

    1973-01-01

    Existing procedures for assessing the quality of shielding of X-ray radiators are compared; these procedures are shown to have a number of shortcomings and to be very time-consuming. A procedure is offered in which shielding quality is tested in two stages: (1) X-ray tests aimed at determining the quality of protection of the X-ray tube unit; and (2) dosimeter tests proper. The results of measurements are compared with maximum permissible dosage rate

  3. Quality control of X-ray equipment in some hospitals of Las Tunas province in Cuba

    International Nuclear Information System (INIS)

    Rodriguez Gonzalez, Maykel

    2008-01-01

    This paper presents the results of the quality controls executed in 33 X-ray rooms of Las Tunas Province in Cuba. Specific tests for the X-ray generators, X-ray Tube, as well as the visualization systems and darkrooms were included. The results also include the estimation of patient doses for some standard radiographic projections (thorax, lumbar spine, abdomen, skull, and pelvis). The results of the evaluation of X-ray equipment was made following the procedures and tolerance included on the technical guidelines elaborated by the National Control Center of Medical Devices, which is the center for regulation of medical devices in the Republic of Cuba. Patient doses obtained were compared with the references levels reported in The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS). (author)

  4. Valorization procedure of x-ray equipment in the mammography equipment

    International Nuclear Information System (INIS)

    Ruiz, M. A.; Ordonez, J.; Antolin, E.; Andres, J. C. de; Gonzalez, I.; Arranz, L.; Sastre, J. M.; Ferrer, N.

    2006-01-01

    The Ramon y Cajal Hospital mammography service has three X-rays units, two of them with high resolution computed radiography (CR) system and one with flat-panel (FP)-based full-field digital mammography system. Periodic control dose tests in patients have shown lower glandular dose levels (DGM) than references provided by European Protocol for de Quality Control of de Physical and Technical Aspects of Mammography Screening. In this work, we have tried to establish an easy method for DGM calculation which is representative of the three equipment results. For this aim, we have defined an index which is measured along the time like a reference point. This index is defined as the relation between the blind test punctuations of a standard phantom image given by at least three radiologists in the Unit, and the average DGM values obtained in 20 patients in each Unit (using random thickness and random mama composition). (Author)

  5. Automated and observer based light field indicator edge evaluation in diagnostic X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bottaro, Marcio; Nagy, Balazs Vince; Soares, Fernanda Cristina Salvador; Rosendo, Danilo Cabral, E-mail: marcio@iee.usp.br [Universidade de Sao Paulo (USP), SP (Brazil); Optics and Engineering Informatics, Budapest University of Technology and Economics, Budapest (Hungary)

    2017-04-15

    Introduction: To analyze edge detection and optical contrast calculation of light field-indicators used in X-ray via automated- and observer-based methods, and comparison with current standard approaches, which do not give exact definition for light field edge determination. Methods: Automated light sensor array was used to measure the penumbra zone of the edge in the standard X-ray equipment, while trained and naive human observers were asked to mark the light field edge according to their own determination. Different interpretations of the contrast were then calculated and compared. Results: In contrast to automated measurements of edge definition and detection, measurements by human observers showed large inter-observer variation independent of their training with X-ray equipment. Different contrast calculations considering the different edge definitions gave very different contrast values. Conclusion: As the main conclusion, we propose a more exact edge definition of the X-ray light field, corresponding well to the average human observer's edge determination. The new edge definition method with automated systems would reduce human variability in edge determination. Such errors could potentially affect the approval of X-ray equipment, and also increase the radiation dose. The automated measurement based on human observers’ edge definition and the corresponding contrast calculation may lead to a more precise light field calibration, which enables reduced irradiation doses on radiology patients. (author)

  6. Automated and observer based light field indicator edge evaluation in diagnostic X-ray equipment

    Directory of Open Access Journals (Sweden)

    Márcio Bottaro

    Full Text Available Abstract Introduction To analyze edge detection and optical contrast calculation of light field-indicators used in X-ray via automated- and observer-based methods, and comparison with current standard approaches, which do not give exact definition for light field edge determination. Methods Automated light sensor array was used to measure the penumbra zone of the edge in the standard X-ray equipment, while trained and naïve human observers were asked to mark the light field edge according to their own determination. Different interpretations of the contrast were then calculated and compared. Results In contrast to automated measurements of edge definition and detection, measurements by human observers showed large inter-observer variation independent of their training with X-ray equipment. Different contrast calculations considering the different edge definitions gave very different contrast values. Conclusion As the main conclusion, we propose a more exact edge definition of the X-ray light field, corresponding well to the average human observer’s edge determination. The new edge definition method with automated systems would reduce human variability in edge determination. Such errors could potentially affect the approval of X-ray equipment, and also increase the radiation dose. The automated measurement based on human observers’ edge definition and the corresponding contrast calculation may lead to a more precise light field calibration, which enables reduced irradiation doses on radiology patients.

  7. Automated and observer based light field indicator edge evaluation in diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Bottaro, Marcio; Nagy, Balazs Vince; Soares, Fernanda Cristina Salvador; Rosendo, Danilo Cabral

    2017-01-01

    Introduction: To analyze edge detection and optical contrast calculation of light field-indicators used in X-ray via automated- and observer-based methods, and comparison with current standard approaches, which do not give exact definition for light field edge determination. Methods: Automated light sensor array was used to measure the penumbra zone of the edge in the standard X-ray equipment, while trained and naive human observers were asked to mark the light field edge according to their own determination. Different interpretations of the contrast were then calculated and compared. Results: In contrast to automated measurements of edge definition and detection, measurements by human observers showed large inter-observer variation independent of their training with X-ray equipment. Different contrast calculations considering the different edge definitions gave very different contrast values. Conclusion: As the main conclusion, we propose a more exact edge definition of the X-ray light field, corresponding well to the average human observer's edge determination. The new edge definition method with automated systems would reduce human variability in edge determination. Such errors could potentially affect the approval of X-ray equipment, and also increase the radiation dose. The automated measurement based on human observers’ edge definition and the corresponding contrast calculation may lead to a more precise light field calibration, which enables reduced irradiation doses on radiology patients. (author)

  8. Quality control for dental X-rays equipment and film developers

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1998-01-01

    Quality control in five dental X-ray equipments, film and film developers was done. It was for evaluating the radiologic practices in the odontologic services too. This work was made based on international standards, the results will be used for future works in quality assurance in dental radiology

  9. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  10. Automated and observer based light field indicator edge evaluation in diagnostic X-ray equipment

    OpenAIRE

    Bottaro, Márcio; Nagy, Balázs Vince; Soares, Fernanda Cristina Salvador; Rosendo, Danilo Cabral

    2017-01-01

    Abstract Introduction To analyze edge detection and optical contrast calculation of light field-indicators used in X-ray via automated- and observer-based methods, and comparison with current standard approaches, which do not give exact definition for light field edge determination. Methods Automated light sensor array was used to measure the penumbra zone of the edge in the standard X-ray equipment, while trained and naïve human observers were asked to mark the light field edge according t...

  11. X ray spectra and qualities for use in diagnostic radiology and equipment calibration

    International Nuclear Information System (INIS)

    Souza, Karla Cristina de

    1996-12-01

    The goal of this work was the standardization of radiation qualities of diagnostic X ray equipment of the Assay Laboratory of the Institute for Radiation Protection and Dosimetry (IRD) of the National Commission of Nuclear Energy, Brazil. X ray spectra were determined from pulse height distribution measured directly on the primary beam using a high pure planar Ge detector. A program was developed to convert pulse height distribution into radiation spectra in the range from 20 to 150 keV. X ray qualities based on those used by the 'Physikalish-Technish Bundesantalt' (PTB) primary laboratory were implanted in three radiological equipment of the Assay Laboratory. These qualities simulate radiation beams on patients submitted to typical radiological examinations. Besides the spectrometric system, a reference measurement system based on an ionization chamber calibrated in air kerma was used to establish parameters such as kilovoltage, first and second half-value layer, mean energy, effective energy and inherent filtration. Our data have shown that the implantation of these radiation qualities in the Assay Laboratory results on a metrological basis for calibration of dose measurement assemblies and kV-meters, like those used by IRD to evaluate the parameters of X ray equipment around the country. A catalogue of spectral data resulting from this work is a data bank that allows various applications like dose calculation using Monte Carlo simulation techniques. (author)

  12. A study on enforcement effects of radiation safety control regulations for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Sung, Mo IL; Park, Myeong Hwan; Kwon, Duk Moon; Lee, Joon IL

    1999-01-01

    The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipment and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of he respondents realized the importance of the radiation safety control system, but about a half of them revealed that regulations were not well observed in accordance with their purposes. Only 43.9 percent of the respondents took an active part in quality control of radiation. And responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Training for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipment. And management of organizations using diagnostic X-ray equipment have to understand and stress the importance of radiation safety control system. (author)

  13. Radiometer evaluation of X-rays equipment in the region of Aracatuba, Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Fernandes, Marco A.R.

    2009-01-01

    This paper presents the basic concepts of radiation protection to guide the health care professionals who use equipment emitting ionizing radiation on the correct handling of the beams of radiation. Radiometric evaluations were conducted in 1665 in X-ray equipment, installed in dental surgeries and clinics, hospitals and radiology services, during the years 1996 to 2003 in the region of Aracatuba. Tests of radiometry are presented as a technical report where the parameters are quantified physical and radiological verifying its compliance with the established by legislation. The distribution of reports by type of unit shows that the vast majority of equipment is of periapical dental x-rays (72%), 25% of equipment is medical equipment for radiology and 3% is dental equipment panoramic model (orthodontic documentation). Among the physical parameters analyzed, the length of the browser was showing more variance compared to the required by law, this fact may also contribute to gaps in the rate of the radiation dose and the size of field in the skin of the patient, the that can easily be resolved simply to replace the piece at the outlet of the head. During the completion of visits to services, it also noted a gap in the training of professionals who operate this equipment emitting radiation, warning of the need for specific training in the area. (author)

  14. The one million volt X-ray therapy equipment at St Bartholomew's Hospital, 1936-1960

    International Nuclear Information System (INIS)

    Innes, G.S.

    1988-01-01

    St Bartholomew's Hospital in 1934 placed a contract with Messrs Metropolitan Vickers, of Manchester, for an X-ray therapy equipment to operate at 600 kV, 2mA d.c., but with the proviso that every effort would be made to attain an operating condition of 1000 kV, 4mA. The X-ray tube and rectifiers were to be continuously evacuated and demountable. This meant that components such as filaments, anodes and the target could be easily replaced, so providing cheap maintenance and continuous availability of the plant. No specification exists today, but one was assembled from the minutes of the Cancer Committee of the hospital and the contract pricing. A brief outline historical review is also presented, particularly of the personalities involved, and the War years 1939-1945. (author)

  15. Possible radiation dose reduction by using digital X-ray equipment

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.; Prikazska, M.

    2001-01-01

    The radiation load of population all over the world from medical examinations clearly demonstrates the importance of the introduction of the quality assurance and quality control programmes into the activities of radiology departments. The basic aim of quality assurance program is to ensure that the radiation dose is kept as low as reasonably practicable while still providing an adequate image quality. As many other fields, the rapid development of techniques brought change-over from the conventional analogue technique to the digital technique. In this process, the conventional X-ray film is being abandoned and images are being viewed on either laser film or monitor. The main advantages of using digital equipment lay in improved image quality and diagnostic accuracy through digital image processing, reduction in patients exposure, cost reduction by reduction of the film usage, more efficient storage and retrieval of radiographic images through picture archiving. Several studies that have been conducted for comparison of various diagnostic examinations show , that there is potential for dose saving in the digital image intensifier technique. The aim of this study was to compare measured values of dose-area product for colon investigations using different X-ray equipment types, two digital and two analogue. Our material consisted of 169 randomly selected patients, 115 of them were examined with digital equipment and 54 patients with the analogue equipment. The obtained results have confirmed the dose reduction and increase of diagnostic accuracy when using the digital equipment, with the added benefit of a good image quality. (authors)

  16. Preliminary evaluation of operational parameters in fixed x-ray diagnostics equipment

    International Nuclear Information System (INIS)

    Bacelar, Alexandre; Oliveira, Sandro Soletti de; Streck, Elaine E.; Furtado, Alvaro Porto Alegre; Pinto, Ana Lucia Acosta

    1998-01-01

    In this work they were appraised 22 fixed X-ray diagnostic equipment belonging to three great medical institutions in Porto Alegre - RS, Brazil, with the purpose of demonstrating the importance of the implementation of a Quality Warranty program, advised by a health physicist, in the performance of these equipment. For so some data of alignment and collimation of the beam, peak tube voltage, tube current, transportable charge and exposition time were collected. The results of the tests showed that in only one of the institutions all the equipment remained in operationally acceptable conditions, with relative percent errors below 10%, concerning to the analyzed parameters. This study also showed that the performance of the equipment of the three analyzed institutions is a direct reflex of the maintenance of a Quality Warranty Program, advised by a qualified professional. (author)

  17. Is there an isotope on your books? Advice to receivers and liquidators on dealing with X-ray sources and X-ray equipment

    International Nuclear Information System (INIS)

    Colgan, Tony.

    1987-01-01

    The paper outlines advice to receivers and liquidators on dealing with radioactive sources and X-ray equipment. When companies go into liquidation it is important that the accountants handling the winding up are aware of the law and their responsibilities if radioactive materials are present. Guidelines are presented here which may help indicate to the accountant the likely presence of radioactive materials and the procedure which should be followed when arranging sale or disposal of these items

  18. Calibration voltage test of non invasive meter for radiodiagnostic on equipment of constant potential X-ray

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Pereira, Marco A.G.S.

    2009-01-01

    This work evaluates the utilization of the non invasive voltage meter PTW Diavolt Universal in industrial X ray equipment of constant potential. With the performed measurements, the conclusion is that conclusion is possible, once his use limits are identified

  19. Equipment to fabricate a masking layer on a carrier by means of soft X-ray

    International Nuclear Information System (INIS)

    Smith, H.I.; Spears, D.L.; Stern, E.

    1978-01-01

    The equipment is to improve the pattern multiplication technique for producing e.g. microminiature current rings. It uses soft X-radiation (2 to 20 A) from an Al anticathode. The mask consists of a Si layer penetrable by X-rays and an opaque pattern layer of Au to limit the mask pattern. Polymethyl metacrylate is suitable as sensitive layer for X-radiation, which is coated on a carrier. The sensitive layer can be prepared from methyl isobutyl ketone and isopropyl alcohol. (ORU/ORU) [de

  20. Evaluation of body simulator for chest and abdomen in digital X-ray equipment

    International Nuclear Information System (INIS)

    Soares, Sidney S.; Cardoso, Gabriela P.; Oliveira, Giovanni Antônio P.; Batista, Adriana S.M.; Pereira, Esther Lorrayne M.

    2017-01-01

    The use of body simulators to control the quality of X-ray images is a practice that guarantees the control of essential parameters for diagnosis by the technique. The evolution of the equipment, between the analogue, digital computerized radiology (CR) and direct radiography (DR), requires evaluation of the equivalence in grayscale, of simulators, for an adjustment according to the specific technology of obtaining the image. In this sense, the present work presents the evaluation of a body simulator with regard to the representation of mean values of signal, noise and contrast obtained in chest radiographs and panoramic of the abdomen. For the thorax the cardiac region was considered as simulation target and for the abdomen simulation of the liver and small intestine. We used a retrospective study of images obtained with X-ray equipment - CR system, in which the images were studied using the ImageJ program, generating a data catalog. These were subsequently compared with those obtained experimentally using gel filled polymer body simulator. For the validation of the simulator, it was observed the gel equivalence of filling of the polymer box required to reach the image parameters of the cataloged radiographs. The results are discussed as to the physical principles of radiation interaction with biological and equivalent tissues

  1. Radiation protection and the safe use of X-ray equipment: Laws, regulations and responsibilities

    Directory of Open Access Journals (Sweden)

    Charles Petrus Herbst

    2012-06-01

    Full Text Available Lately, South Africa’s regulatory framework for electromagnetic medical devices has come under considerable pressure. In this article the legislative framework and regulatory infrastructure are scrutinized, by looking at how the legislature has given form to protective measures against ionizing radiation. Although the Hazardous Substances Act provides for effective protection against radiation, poor administration led to insufficient staffing levels, uncertainty about Regulations and licensing conditions and therefore undermines a sound radiation protection infrastructure. The legal basis of enforcing licensing conditions through a website without proper consultation with interested and affected parties is questionable and ineffective in controlling radiation levels. Effective and legal radiation control is possible by activating the National Advisory Committee on Electronic Products provided for in Regulation R326 published in 1979, but never implemented. The possible impact of annual quality assurance tests currently enforced through licensing conditions on the radiation dose of the population is not cost effective as new training and accreditation structures had to be created. The fact that generally more than 80% of overexposures are caused by human error is a clear indication that training of the daily users of X-ray equipment should be emphasized and not the training and accreditation of the technicians responsible for a single quality assurance test per year. Constructive engagement with the professional bodies involved in the medical use of X-rays through a National Advisory Committee on Electronic Products may be a cost effective solution for lowering radiation dose to the population.

  2. Development of a dosimetric system for dental X-ray equipment quality control

    International Nuclear Information System (INIS)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  3. Knowledge of the power of an X-ray equipment; Conhecimento da potencia de um equipamento de raios-X

    Energy Technology Data Exchange (ETDEWEB)

    Paula, Vitor Moura de; Andrade, Lucio das Chagas de; Peixoto, Jose Guilherme Pereira, E-mail: vmoura@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    After we raise a power response curve on the load for the X-ray equipment, we define the region of trial operation and compared with the theoretical, and thus conclude that it is very important for operation of the X-ray equipment, it may set the amount of dose that patients receive in a future exhibition and operating threshold, so that the equipment is not extrapolated and may suffer damage. For the same rating there is a difference of 0.99% between readings found in the same power operation. (author)

  4. Methods for improvement of some parameters of medical X-ray diagnostic equipment. Basic faults in selection of appropriate new or used units

    International Nuclear Information System (INIS)

    Tonev, M.; Danev, N.; Constantinov, B.

    2004-01-01

    An analysis is made of the factors determining the quality and performance of the main types of medical equipment: conventional radiographic and fluoroscopic X-ray unit; X-ray computer tomograph (CT); angiographic, mammographic, densitometric and dental X-ray equipment; magnetic resonance MRI. The aim is to give certain directions for the method one should adopt on choosing and purchasing X-ray equipment. Also one should take into consideration the new Health law and the Regulation for radiation protection of persons undergoing medical examination or treatment. The problems can be solved with the close cooperation between radiologists, medical physicists and x-ray engineers

  5. Total reflection x-ray fluorescence spectrometers for multielemental analysis: status of commercial equipment

    International Nuclear Information System (INIS)

    Ayala Jimenez, R.E.

    2000-01-01

    Multi-elemental analysis by total reflection x-ray fluorescence spectrometry has evolved during two decades. At the present there are commercial equipment available for the chemical analysis in all kind of biological and mineral samples. The electronic industry has also been benefited from the scientific and technological developments in the field of TXRF. The basic components of the spectrometers can be summarized as follow: a) excitation source; b) geometric arrangement (optics) for collimation and monochromatization of the primary radiation; c) x-ray detector; d) hardware and software for operation of the instrument, data acquisition and spectral deconvolution to determine the concentrations of the element present in the sample (quantitative analysis). As optional there are manufacturers offering the conventional 45 degrees geometry for direct excitation of bulky liquid or solid samples. Personal communications of the author and the commercial brochures available at the moment of writing this presentation have allowed to list the following type of components used in the TXRF spectrometers for multi-elemental analysis (the devices used in the electronic industry to analyze silicon wafers are excluded). Excitation: high power x-ray tube, output from 1300 to 2000 watts; metal ceramic low power-ray tube, output up to 50 watts. Different anodes are used but molybdenum, tungsten and copper are frequent. The excitation systems can be customized according to the requirements of the laboratory. Detector: Si-Li semi-conductor liquid nitrogen cooled; silicon solid state thermoelectrically cooled (silicon drift detector SDD and Si-PIN diode). Optics: multilayer monochromator of Si-W or Ni-C; double multilayer monochromator. Electronics: spectroscopy amplifier, analog to digital converter adapted to a PC compatible computer with software in Windows environment for the whole operation of the spectrometer and for qualy/quantitative analysis of samples are standards in the

  6. Safety code 19: recommended safety procedures for the selection, installation and use of x-ray diffraction equipment

    International Nuclear Information System (INIS)

    1984-01-01

    This document is one of a series of Safety Codes prepared by the Radiation Protection Bureau to set out requirements for the safe use of radiation emitting devices. The equipment and installation guidelines and safety procedures detailed in this Code are primarily for the instruction and guidance of persons employed in Federal Public Service Departments and Agencies, as well as those coming under the jurisdiction of the Canada Labour Code. This Safety Code is also intended to assist other users of X-ray diffraction equipment to select safe equipment and to install and use it so that the radiation hazard to the operator and other persons in its vicinity is negligible. It should be noted that facilities under provincial jurisdiction may be subject to requirements specified under provincial statutes. This Code supersedes Safety Code RPD-SC-7, entitled 'Requirements For Non-Medical X-Ray Equipment, Use and Installation', insofar as X-ray diffraction equipment is concerned, and it is intended to complement X-ray equipment design, construction and performance standards promulgated under the Radiation Emitting Devices Act

  7. Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd

    Directory of Open Access Journals (Sweden)

    D.Goodarzi Pour

    2005-02-01

    Full Text Available Statement of Problem: A few decades have past from using radiographic technology as an accurate paraclinical method and always protective measurements is applicated against ionizing radiation. As dentalradiography is a routine procedure in dentistry the importance of protective strategies is clear.Propose: The aim of this descriptive study is to evaluate the protection principles in centers which haveintraoral radiographic devices in Yazd.Material and Methods: We have considered all three aspects of practitioner, environment and patientprotection using questionnaire and visiting those centers.Results: 33/7% of dental offices ,10 clinics ,3 institution and faculty of dentistry had intraoral radiographicequipments. Stablishment of protection principles for radiographer was favorable. 7.7% of centers had x-ray room with leaded walls, 23.1% had curtain , in 69/2% of centers radiographers stood in correct position anddistance while taking radiograph. Regarding to protection of environment, beams leakage control in 23.1% dental offices, 70% of clinics, all institution and faculty of dentistry have done.Conclusion: Non of the centers used rectangular localizator, thyroid shield, film holder and just some centers used leaded apron in specific circumstances. We have concluded that patient protection constitute less consideration. Generally lack of protective consideration is related to deficient knowledge of operators. Lackof information about protection equipments causes decrease of demanding of these tools and ultimately lack of these equipments in the market.

  8. Code of safe practice for the use of x-ray analytical equipment

    International Nuclear Information System (INIS)

    2001-01-01

    This 'Code of safe practice' covers the use of fluoroscopic x-ray security systems for screening of baggage, mail or people, and fluoroscopic x-ray inspection systems used for quality control inspection of foodstuffs (detection of foreign bodies), and manufactured items such as tyres and wheel castings. (author). 3 refs

  9. Portable energy-dispersive X-ray fluorescence equipment for the ...

    Indian Academy of Sciences (India)

    Abstract. Energy-dispersive X-ray fluorescence (EDXRF) especially in its portable version, generally characterized by a small X-ray tube and a Si-PIN or ... of all types (including frescos and illuminated manuscripts), bronzes and brasses, gold alloys, silver alloys, ceramics, porcelains and faiences, papers, ink, stones of all ...

  10. OPINION Radiation protection and the safe use of X-ray equipment ...

    African Journals Online (AJOL)

    an indispensable role in clinical management of patients. The annual worldwide number of X-ray procedures has been ... The innovative use of radiation, and specifically X-rays, imposes risks if inadequately controlled by suppliers, users and government. Concerns about the possible effects of exposure to radiation on the ...

  11. The physical and biomedical characteristics of the novel transmission type X-ray equipment

    International Nuclear Information System (INIS)

    Hsu, S.M.; Wang, S.F.; Hsieh, Y.J.; Cheng, C.C.; Liao, Y.J.

    2016-01-01

    The radiation output characteristics of the transmission-target X-ray tube are different from those of the traditional reflection-target X-ray tube. The aims of this study were to compare the differences of output dose and spectrum between these two X-ray tubes under the same conditions. The biomedical applications of the transmission-target X-ray in liver cancer cells were also evaluated. For these two systems, the dose output and the mAs appeared to have good linear relations; the dose output and kVp variations also had positive relations. However, under the same parameters, the dose output of transmission-target X-ray system was 2.64–3.21 times higher than the reflection-target system, implying that the transmission-target system had a higher X-ray production rate. The K characteristic radiations reach 22.96% and 8.91% of the spectrum in transmission-target and reflection-target, respectively. The spectrum measurements showed that the transmission-target system had more obvious output of K characteristic radiation. The 1 Gy of transmission-target can induce 16%–23% of cytotoxicity in liver cancer cells. Concerning the synergic effects of transmission-target combined with rose bengal, the data showed that 1 Gy of transmission-target exposure augment the 24%–28% of cytotoxicity at low dose of rose bengal treated condition. - Highlights: • The transmission-target X-ray system had a higher X-ray production rate. • The transmission-target X-ray system had more obvious output of K characteristic radiation. • The transmission-target X-ray enhanced rose bengal induced cytotoxicity in liver cancer cells.

  12. Equipment performance and radiation protection status in X-ray fluoroscopy units in Sudan

    International Nuclear Information System (INIS)

    Ahmed, N. A.; Nayl, A. I.; Suliman, I. I.

    2012-01-01

    The number of fluoroscopy and fluoroscopically guided procedures has been substantially growing in developing countries at the same time advanced and sophisticated equipment are used in some hospitals. However, radiation protection requirements are not necessarily well adopted. In this study nine fluoroscopy X-ray units in Sudan were examined for compliance with international standards. The tests included: beam quality, entrance surface air kerma, image quality and radiation field measurements. Staff radiation protection tools such as lead aprons and eye glasses were also visually examined to find out whether international recommendations were fulfilled and to determine the level of staff awareness. The measured peak tube voltage deviation exceeded the recommended tolerance level in 30 % of the measurements. The results of patient doses measurements exceeded the recommended reference dose levels in 43 % of the measurements; however image quality and radiation field generally fulfilled the requirements for most units. The study revealed that a considerable number of fluoroscopy units were not performing according to the international standards and highlights the need of optimisation of radiation protection. (authors)

  13. Direct magnification radiography of newborn with mobile X-ray equipment

    International Nuclear Information System (INIS)

    Fukai, Kazuhiko; Kigure, Hatsuo; Hatori, Noboru; Shinohara, Yasuji.

    1989-01-01

    Small patient size is a major factor of the difficulty in interpreting the newborn infant radiograph. Direct radiographic magnification can be employed to relieve this problem and special positioning devices were made to image the infant, confined to incubator and connected to life-supporting systems. The mobile X-ray equipment with a microfocus (0.2 mm) radiographic tube, a rare-earth high-speed recording system and carbon cassette were combined to obtain a radiograph at magnification of 1.5-2.0. Image quality was superior to that of conventional contact radiographic system, but infant radiation exposure was 26% more than that of conventional study. Although direct radiographic magnification was very useful to recognize subtle or equivocal abnormality which could not be made from conventional image, its application should be restricted to specific disease at this present, considering infant radiation exposures. This technique will have wide clinical application when radiation exposure can be reduced by using other recording system such as computed radiography (CR). (author)

  14. Compliance testing of medical diagnostic x-ray equipment: three years experience of a public hospital in western Australia

    International Nuclear Information System (INIS)

    Tuchyna, T.; Jacob, C.S.

    2000-01-01

    Full text: A formal compliance testing program which began on 1 January 1997 called for all medical and diagnostic x-ray equipment to be tested according to protocols established by the Western Australian Radiological Council. This work describes the impact of the legislation three years post implementation on a major teaching Hospital with 45 x-ray tubes located throughout 37 rooms. Testing is performed prior to scheduled service by licensed compliance testers according to test methods specified in the Western Australian Compliance Testing Workbook, 1997. A dedicated non-invasive x-ray beam analyser is instrumental in accurately determining radiation output parameters of the generator and x-ray tube. Assessment of compliance is determined by a Qualified Expert. Repair and re-testing of non-compliant items is coordinated with service personnel. Notices of non-compliance were received for approximately 60% of the equipment in the Hospital following the equipment' first annual test. Reasons and seriousness of failure varied according to equipment category, test category, equipment use and age. The majority of non-compliance issues were resolved within 90 days. At the end of the third year of testing, approximately 75% of the x-ray units tested met the compliance criteria. The main reasons for non-compliance were found to be design limitations associated with old technology and the current radiation legislation that makes it difficult for older equipment to meet the stringent criteria. The number and categories of failure did not significantly decrease in the second or third years of testing. Exemptions from compliance criteria have been sought for two units on the basis of age and design. Units unable to meet the criteria following several repair attempts or where the cost of repair was deemed not justified, were decommissioned. Formal testing of medical x-ray equipment has demonstrated various non-compliance issues that did not significantly improve during the

  15. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won [Division of Medical Device Research, National Institute of Food and Drug Safety Evaluation, Mnistry of Food and Drug Safety (Korea, Republic of)

    2016-12-15

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

  16. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    International Nuclear Information System (INIS)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won

    2016-01-01

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts

  17. Simple microprocessor-based system for upgrading existing X-ray equipment for analysis

    International Nuclear Information System (INIS)

    Souza, A.M. de

    1986-01-01

    A data acquisition and processing device appropriate for X-ray analysis and goniometer control was built. A conventional Z-80 based systems was used, and the interfacing architeture and the applicable soft-ware are described. The advantages and new possibilities of the automated instrument as compared to previous ones are listed. It is shown that the X-ray diffraction and fluorescence techniques can take advantage of the automation using existing instruments. (Author) [pt

  18. Methodology of ionizing radiation measurement, from x-ray equipment, for radiation protection

    International Nuclear Information System (INIS)

    Caballero, Katia C.S.; Borges, Jose C.

    1996-01-01

    Most of X-rays beam used for diagnostic, are short exposure time (milliseconds). Exception are those used in fluoroscopy. measuring instruments (area monitors with ionizing chambers or Geiger tubes) used in hospitals and clinics, in general, have characteristic answer time not adequate to X-rays beams length in time. Our objective was to analyse instruments available commercially, to prepare a measuring methodology for direct and secondary beams, in order to evaluate protection barriers for beams used in diagnostic radiology installations. (author)

  19. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    International Nuclear Information System (INIS)

    Murata, C.H.; Fernandes, D.C.; Lavínia, N.C.; Caldas, L.V.E; Pires, S.R; Medeiros, R.B.

    2014-01-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  20. Evaluation and characterization of digital X-ray equipment for paediatric cardiology in the Hospital Gregorio Maranon

    International Nuclear Information System (INIS)

    Calama Santiago, J. A.; Gonzalez Ruiz, C.; Infante Utrilla, M. A.; Zanfano Hidalgo, R.; Penedo cobos, J. M.; Sierra Diaz, F.; Olivares Munoz, M. P.

    2006-01-01

    The purchase of a digital X-Ray equipment specific for paediatric cardiology in 2003 has allowed a careful examination of the technical characteristics of these patients. This data review includes the analysis of a dose index with several variable factors such as weight, size and age of patients, purpose, type and characteristics of the study and its development over time as a results of the experience gained by the staff involved. (Author)

  1. Management of radiodiagnostic equipment: Implementation of self-maintenance project of the conventional x-ray equipment of Hospital Universitario Clementino Fraga Filho - HUCFF-UFRJ

    International Nuclear Information System (INIS)

    Couto, N.F. do; Azevedo, A.C.P.; Koch, H.A.

    2001-01-01

    The project aims the implantation of a management program, for the maintenance of the conventional X-ray equipment at HUCFF. It has been implemented through the training of the electronic technicians who work at the Hospital. Essential courses were organized such as: Basics of Radioprotection, Radiographs Techniques, and Maintenance of equipment of X-Rays. Equipment: a library with the schemes of the equipment is being assembled in collaboration with UNICAMP. In order to manage the process, a software was created using the tools of the total quality for control of the maintenance. Preliminary tests: the equipment and their working conditions were evaluated, as well as the level of the employees' satisfaction with their use. The creation of a new routine for maintenance seeks to assist the demands of the new legislation in Brazil 5, and also reduce the costs to improve the quality of the images in the Radiodiagnostic Service. (author)

  2. The main tests for quality control in X-ray equipment of radiodiagnosis

    International Nuclear Information System (INIS)

    Ferreira, R.S.

    1988-01-01

    All aspects of the relation between patient, examination and diagnosis for controling the quality in radiodiagnosis are showed. The bundle collimation for decreasing the scattered radiation in patient and the systems for measuring the exposure time are described. The yield valuation and the tension for X-rays tube are also cited. (C.G.C.) [pt

  3. Structure, characteristics and potential of commercial equipment Total Reflection X Ray Fluorescence for multielemental chemical analysis: Current State

    International Nuclear Information System (INIS)

    Ayala Jimenez, Rony E.

    1999-01-01

    The method Total Reflection X-Ray Fluorescence for chemical multielemental analysis has evolved in the last years with the availability of commercial systems for applications in the field of electronics and chemical multielemental analysis in samples of mineral and biological origin. The basic components of these equipment cam be summarized in a system of excitement, a geometric arrangement (optics) for collimate and monochromatize the primary radiation, a X-rays detector, and the electronic si stem for spectral data acquisition including the software for spectra unfolding, qualitative and quantitative analysis, and the complete instrument operation. Additionally the makers offer the conventional 45 degrees geometry for the excitement solid and liquid samples of bigger volume in direct form. The available bibliographical and commercial information to the moment of preparing this lecture, basically reports the following types of components for the X-rays spectrometers in geometry of total reflection chemical multielemental analysis (they are excluded those RTFX equipment dedicated to the electronic industry for quality control of Si wafers purity used for the production of circuits (chips). Excitation: X-rays tube of high vacuum with power among 1300 to 2000 watts and different types of anode; X-rays ceramic metal tube, with power up to 40 watts, and anode of molybdenum, tug steno, etc. Detection: detector semiconductor of silicon-lithium cooled with liquid nitrogen; detector of solid state silicon cooled electrically (Si-PI N diode or detector of diffused silicon Sdd). Optics: multi stratum monochromator; multi stratum Ni-C monochromator; double multi stratum monochromator. Electronic: spectroscopical amplifier espectroscopico and ana logical digital convertor adapted to a personal computer IBM compatible, with software for qualitative and quantitative analysis of samples by means of Windows, and for the complete operation of the analyzer from the Pc. In this work

  4. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A bone x-ray is used to: ... and x-rays. top of page What does the equipment look like? The equipment typically used for ...

  6. Doses in the vicinity of mobile x-ray equipment in a children's intensive care unit

    Energy Technology Data Exchange (ETDEWEB)

    Milkovic, D. [Hospital of Lung Diseases for the Children and Youth, Srebrnjak, Zagreb (Croatia); Knezevic, Z.; Ranogajec-Komor, M. [Ruder Boskovic Institute, Zagreb (Croatia); Bozinovic, D. [Clinic for Infectius Diseases ' Dr. Fran Mihaljevic' , Zagreb (Croatia)

    2000-05-01

    Most of the patients in the Intensive Care Unit for Children are new-borns and infants having an infection of the central nervous system, with systemic septic and respiratory infections. Therefore, mobile X-ray equipment is routinely used for diagnosis of the respiratory tract, heart and endovascular catheterization. The aim of this work was to determine the radiation exposure to children in the vicinity of the exposed patient in the same or next room. The mobile X-ray unit is a Phillips Practix 100 model, including mobile shields (made by the firm Weimer Strahlenschutz) for radiation protection of patients and personal. For dose measurements, a thermoluminescent dosimetry system with TLD-700 detectors (manufactured by Harshaw) and a microprocessor controlled TOLEDO 654 reader were used. Three measurement runs were carried out. In the first one, the dosimeters were placed on the bed, without the patient, and the x-ray unit was operated as for thoracic x-ray. The results show the adequate homogeneity of the irradiation field. In the second measurement run, dosimeters were placed on the neighbouring bed behind the shield as well as on the glass wall of the room at various heights and distances from the X-ray tube. The results show that doses are very low, practically in the range of the lowest detectable dose, about 5 {mu}Sv. In the 3rd measurement run, the configuration of dosimeters in the surroundings were the same, but the irradiation was carried out with a 2 year old female patient and the distribution of the patient's surface dose was measured. The entrance dose on the breast was found to be 0.17 mSv. The results of this study show that the exposure of children to radiation in the vicinity of the exposed patient in the same or next room is not measurable. Therefore there is no basis for the risk estimation of genetic, leukemogenic and cancerogenic detriment. (author)

  7. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    International Nuclear Information System (INIS)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A.; Fernandes, Angela; Westphalen, Fernando Henrique

    2013-01-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  8. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A., E-mail: alanacarolinef@gmail.com, E-mail: sergei@utfpr.edu.br [Universidade Tecnologica Federal do Parana (CPGEI/UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduacao em Engenharia Eletrica e Informatica Industrial; Fernandes, Angela; Westphalen, Fernando Henrique, E-mail: angelafernandes@ufpr.br [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Setor de Ciencias da Saude

    2013-07-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  9. Small intestine biopsy of children with coeliac disease: Influence of X-ray equipment on radiation dosage

    Energy Technology Data Exchange (ETDEWEB)

    Persliden, J. [Dept. of Radiation Physics, Faculty of Health Sciences, Linkoeping Univ. (Sweden); Pettersson, H.B.L. [Dept. of Radiation Physics, Faculty of Health Sciences, Linkoeping Univ. (Sweden); Stenhammar, L. [Dept. of Paediatrics, Central Hospital, Linkoeping (Sweden); Faelth-Magnusson, K. [Dept. of Paediatrics, Faculty of Health Sciences, Linkoeping Univ. (Sweden)

    1994-10-01

    In paediatric radiology intestinal biopsies for the diagnosis of coeliac disease are performed using fluoroscopy. The radiation exposure to the child depends on the X-ray equipment. We report patient measurements from three different equipments (A, B and C) together with a phantom study simulating children of different thicknesses relative to age. The median values of the mean absorbed dose to the child in the irradiated volume were 1.2 mGy (A), 0.79 mGy (B) and 0.15 mGy (C). The results show that the increase in tube potential with increasing distance in one equipment decreases the dosage, and also that modern equipment should be employed. Particularly old image intensifiers should not be used. With an optimal choice of equipment the dosage to the child can be reduced fourfold. The combination of an optimal technique of sedation and an experienced operator can reduce the dosage tenfold. (orig.)

  10. Instrumentation system for multi measure of parameters of diagnosis X-ray equipment; Sistema de instrumentacao de multimedicao de parametros de equipamentos de raios-X diagnosticos

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Luiz A.P.; Monte, David S.; Santos, Jose A.P., E-mail: lasantos@scients.com.br [Scients, Recife, PE (Brazil); Cavalcanti, Francisco A.; Barros, Fabio R.; Santos, Marcus A.P., E-mail: frbarros@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    Innovative methodologies of a Multi-measuring instrumentation system the following parameters: CSR kVp, kerma air kerma rate, exposure time, field size and the number of X-ray pulses are presented. Thus, the instrument applies both to measure some parameters of conventional X-ray equipment as dental equipment. The methods used are based on modern electronic measurement techniques Sensor unconventional X-rays, such as bipolar junction transistor (BJT) with a certain bias electrical signals. In fact, the proper polarization allows to measure each parameter or magnitude from interference of photons in the device converting the TBJ of the output signal in a modulated signal by Interaction of radiation. The output signal is then processed by a microprocessor to convert the greatness or endpoint of the X-ray equipment. The results show that the multi-measuring system has proposed a relative uncertainty 1% and 5% for kVp and CSR parameters, respectively, for conventional x-ray equipment, and less than 1% for the exposure time in equipment dental X-rays. The proposed system brings innovation to the art and has metrological character providing be applied to quality control of diagnostic X-ray equipment.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-rays. top of page What does the equipment look like? The equipment typically used for bone x-rays consists of ... and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely available in emergency ...

  12. Metrological analysis of constancy tests in conventional medical X-ray equipment

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Oliveira, Paulo Marcio C.; Squair, Peterson L.; Soares, Carlos M.; Silva, Teogenes A. da

    2005-01-01

    Constancy tests in x-ray diagnostic machines should follow performance requirements with the aim to verify their safety and quality and to protect workers, patients and public members that are or may be exposed to ionizing radiation risks. In the Brazilian state of Minas Gerais, from 1999 to 2004, 110 radiometric and evaluation reports of x-ray machines were issued by accredited professionals. Most of the reports did not provide the estimation of the measurement uncertainty that should be part of the results; it means that there is a lack of metrological care in such reports which may cause difficulties to get a conclusive analysis. In this work, relevant sources of uncertainties were identified and estimated for the following tests carried out in a conventional x-ray machine: high voltage accuracy and reproducibility, air kerma rate repeatability and linearity and half-value layer determination. This work gives details on the methodology and the expanded and combined uncertainty values for each measuring procedure, which may be adopted as representative values for analysis of radiometric report. (author)

  13. Method of protection of the electronic equipment from pulse X-ray radiation

    Directory of Open Access Journals (Sweden)

    Gnatyuk V. S.

    2017-12-01

    Full Text Available X-ray units with high instantaneous intensity are used in the course of nondestructive testing of massive articles, in radiation tests, and also to impart new properties to various polymer materials. Under these conditions, the input cascades of measuring systems designed to monitor the parameters of processes are subject to a powerful X-ray flux. The flux generates avalanche of secondary electrons in the sensitive part of the primary measuring transducers, which leads to their failure or temporary inoperability due to the thyratron effect in p-n transitions of semiconductor electronic devices. The work has shown the possibility of protecting the input cascades of electronic devices in the ionization zone by shunting the power circuits in real time. Shunting is ensured by the creation in the protective device of high conductivity by the same radiation flux. The possibility of creating protective devices based on semiconductor chambers with walls with high braking power has been considered. The radiation forms in the wall of the chamber a high level of secondary electrons flowing through the plate from a semiconductor with high mobility of conduction electrons. Conduction electrons are formed in a semiconductor in the last stages of electron avalanches caused by high-energy secondary electrons. Such opportunity has been confirmed with calculations for the specific camera with a wall from lead in which the plate from gallium arsenide is placed. The calculations have been carried out for a wall by thickness equal to average length of the free run of a photoelectron. In this case, the electron equilibrium condition is present, that is, the number of secondary electrons produced in the wall as a consequence of the internal photoelectric effect will be equal to the number of electrons absorbed by the wall, but the flux of X-ray photons does not change appreciably. Compliance with this condition gives the greatest shunting effect.

  14. Evaluation of absorbed radiation dose rate in a didactic X-ray equipment

    International Nuclear Information System (INIS)

    Costa, Phelipe Amaral Ferreira; Perini, Ana Paula; Neves, Lucio Pereira

    2016-01-01

    This work was performed in order to create a new didactic experiment in the X-ray apparatus of PHYWE, where the saturation current was obtained through a free air ionization chamber. The values of saturation currents were obtained in two ways. Initially, the anodic DDP was kept constant and the anodic current was varied. In the second way, the anodic current was kept constant while the anodic DDP was varied. Therefore, we were able to evaluate the dependence of the absolved dose rate in relation to the DDP and the tube current. (author)

  15. Preparatory procedure and equipment for the European x-ray free electron laser cavity implementation

    Directory of Open Access Journals (Sweden)

    D. Reschke

    2010-07-01

    Full Text Available The European x-ray free electron laser is under construction at Deutsches Elektronen-Synchrotron (DESY. The electron beam energy of up to 17.5 GeV will be achieved by using superconducting accelerator technology. Final prototyping, industrialization, and new infrastructure are the actual challenges with respect to the accelerating cavities. This paper describes the preparation strategy optimized for the cavity preparation procedure in industry. For the industrial fabrication and preparation, several new hardware components have been already developed at DESY. The design and construction of a semiautomated rf-measurement machine for dumbbells and end groups are described. In a collaboration among FNAL, KEK, and DESY, an automatic cavity tuning machine has been designed and four machines are under construction. The functionality of these machines with special attention to safety aspects is described in this paper. A new high pressure rinsing system has been developed and is operational.

  16. Simulated performance of a single pixel PIN spectrometer SCXM equipped with a concentrator optics in Solar coronal X-ray observations

    Science.gov (United States)

    Alha, L.; Huovelin, J.; Nevalainen, J.

    2012-02-01

    In this paper we present simulated solar coronal X-ray observations to verify the sensitivity of a new hypothetical instrument design. These simulations are folded through this X-ray spectrometer having a moderate size circular field of view (FoV) of 1.6°. This SCXM (Solar Coronal X-ray Mapper) is designed to compose of a single pixel silicon PIN detector equipped with a single reflection double frustum X-ray optics. A moderate FoV would enable a morphological study of the expanded X-ray emission from the solar corona during a high activity of the Sun. The main scientific task of SCXM would be the mapping of the coronal X-ray emission, i.e. to resolve the radial distribution of the X-ray surface brightness around the Sun. These kinds of off-limb observations would help to interpret the coronal plasma diagnostics as a function of the elongation angle.Direct solar full disc observations could be also performed with SCXM. In this work we have applied real solar coronal X-ray data obtained by the SMART-1 XSM (X-ray Solar Monitor) [3] to simulate on-solar observations at different flux levels to derive full disc sensitivity and performance of SCXM.A challenging attempt for SCXM would also be to distinguish the X-ray spectrum of the decaying axions around the Sun. These axions are assumed to be created as side products of fusion reactions in the core of the Sun. These axions are predicted to be gravitationally trapped to orbit the Sun forming a halo-like X-ray emitting object. No signature of an axion X-ray emission around the Sun has been observed to this day.This simple X-ray spectrometer with an optical concentrator would be an inexpensive instrument with low mass and telemetry budgets compared with more accurate X-ray instruments of imaging capability. Hence SCXM would be an advanced choice as an auxiliary instrument for solar coronal X-ray observations.

  17. X-ray apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Stagg, L.; Lambert, T.W.; Griswa, P.J.

    1976-01-01

    A patient support system for X-ray equipment in arteriographic studies of the heart is described in detail. The support system has been designed to overcome many of the practical problems encountered in using previous types of arteriographic X-ray equipment. The support system is capable of horizontal movement and, by a series of shafts attached to the main support system, the X-ray source and image intensifier or detector may be rotated through the same angle. The system is highly flexible and details are given of several possible operational modes. (U.K.)

  18. Instrumental parameters' determination in a fluorescences X-ray Philips PW 1400 equipment

    International Nuclear Information System (INIS)

    Martinez, J.M.; Fasio, I.; Baronio, N.; Viola, M.

    1987-01-01

    The instrumental parameters of a Philips PW 1400 equipment wavelengths dispersive are determined; fundamentally, those related to the equipment's accuracy (stability at a very short, short and long term drift) as well as to those related to the detection system (dead time, detector's cleaning and detection limit). (S.M.) [es

  19. Evaluation of TLD dose response compared to MCNP-5 simulation of diagnostic X ray equipment - radiation diagnostic image

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez G, R.; Cavalieri, T. A.; De Paiva, F.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares, Centro de Engenharia Nuclear / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rodrigues F, M. A. [Universidade Estadual Paulista, Faculdade de Medicina de Botucatu, Departamento de Dermatologia e Radioterapia, Av. Prof. Montenegro s/n, Rubiao Junior, 18601-970 Botucatu (Brazil); Vivolo, V., E-mail: chancez@hotmail.com [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The thermo luminescent dosimeter (TLD) is used as a radiation dosimeter and can be used as environmental and staff personnel monitoring. The TLD measures ionizing radiation exposure by a process in which the amount of radiation collected by the dosimeter is converted in visible light when the crystal is heated. The amount of emitted light is proportional to the radiation exposure, and then the response of the TLD must be the related to the real dose. In this work it was used twenty four TLD 700 in order to obtain eight values of doses from a diagnostic X-ray equipment. The TLD-700 is a LiF TLD enriched with {sup 7}Li isotope. One way to compare and study the response of TLD is by Monte Carlo method, which has been used as a computational tool to solve problems stochastically. This method can be applied to any geometry, even those where the boundary conditions are unknown, making the method particularly useful to solve problems a priori. In this work it was modeled the X-ray tube exactly as the one used to irradiate the TLD, after the simulation and the TLD irradiation the results of dose value from both were compared. (Author)

  20. Evaluation of TLD dose response compared to MCNP-5 simulation of diagnostic X ray equipment - radiation diagnostic image

    International Nuclear Information System (INIS)

    Sanchez G, R.; Cavalieri, T. A.; De Paiva, F.; Dalledone S, P. de T.; Yoriyaz, H.; Rodrigues F, M. A.; Vivolo, V.

    2014-08-01

    The thermo luminescent dosimeter (TLD) is used as a radiation dosimeter and can be used as environmental and staff personnel monitoring. The TLD measures ionizing radiation exposure by a process in which the amount of radiation collected by the dosimeter is converted in visible light when the crystal is heated. The amount of emitted light is proportional to the radiation exposure, and then the response of the TLD must be the related to the real dose. In this work it was used twenty four TLD 700 in order to obtain eight values of doses from a diagnostic X-ray equipment. The TLD-700 is a LiF TLD enriched with 7 Li isotope. One way to compare and study the response of TLD is by Monte Carlo method, which has been used as a computational tool to solve problems stochastically. This method can be applied to any geometry, even those where the boundary conditions are unknown, making the method particularly useful to solve problems a priori. In this work it was modeled the X-ray tube exactly as the one used to irradiate the TLD, after the simulation and the TLD irradiation the results of dose value from both were compared. (Author)

  1. Regulations No. 493 of 8 September 1977 on X-ray equipment up to 70 kV for dental purposes

    International Nuclear Information System (INIS)

    1977-01-01

    These regulations lay down the requirements to be complied with for the protection of medical staff and patients when using X-ray equipment for dental purposes. The operators of such equipment must comply with the technical guidelines contained in the regulations and provision is made for annual inspections to ensure that the devices meet the necessary safety standards. (NEA) [fr

  2. A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry

    International Nuclear Information System (INIS)

    Dong, Kyung Rae; Kim, Ho Sung; Jung, Woon Kwan

    2008-01-01

    Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bone density equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bone density can be accurately and precisely reflected when used it compatibility like the existing equipment after equipment replacement and expansion. Two equipment of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). It is steady equipment according to daily Q.C Data with 0.996 g/cm 2 , change value(%CV) 0.08. The meanSD and a %CV price are ALP in Group 1(P1 : , , P2 : , %CV=0.192). The mean±SD and a %CV price are P1 : 1.064±0.002 g/cm 2 , %CV=0.190 g/cm 2 , P2 : 1.061±0.003 g/cm 3 , %CV=0.163 in Group 2. The average error±2SD and %CV are P1 - (spine: 0.001±0.013 g/cm 2 , %CV=0.94, Femur: 0.001±0.019 g/cm 2 , %CV

  3. A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health College, Gwangju (Korea, Republic of); Kim, Ho Sung [Dept. of Nuclear Medicine, Asan Medical Center, Seoul (Korea, Republic of); Jung, Woon Kwan [Dept. of Nuclear Energy Technology, Chosun University, Gwangju (Korea, Republic of)

    2008-03-15

    Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bone density equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bone density can be accurately and precisely reflected when used it compatibility like the existing equipment after equipment replacement and expansion. Two equipment of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). It is steady equipment according to daily Q.C Data with 0.996 g/cm{sup 2}, change value(%CV) 0.08. The meanSD and a %CV price are ALP in Group 1(P1 : , , P2 : , %CV=0.192). The mean{+-}SD and a %CV price are P1 : 1.064{+-}0.002 g/cm{sup 2}, %CV=0.190 g/cm{sup 2}, P2 : 1.061{+-}0.003 g/cm{sup 3}, %CV=0.163 in Group 2. The average error{+-}2SD and %CV are P1 - (spine: 0.001{+-}0.013 g/cm{sup 2}, %CV=0

  4. Comparing of the yield curve of the pediatric X-ray equipment using thermoluminescent dosimeters and cylindrical ionization chamber

    International Nuclear Information System (INIS)

    Filipov, Danielle; Schelin, Hugo R.; Tilly Junior, Joao G.

    2014-01-01

    The determination of the yield curve of a radiographic equipment should be realized once a year, or when the unit be serviced. Besides being a requirement of ANVISA, through this test is possible to determine the incident air kerma (at a given point in the center of the beam) - INAK. Based on these concepts, the main objective of this work is the comparison of yield curves of the pediatric X-ray apparatus using two different detectors: one cylindrical ionization chamber and thermoluminescent dosimeters type LiF: Mg, Cu, P, as per protocol RLA / 9/057 IAEA. Then the equation of the yield curve (generated by each detector) was used to determine the INAK of 10 pediatric examinations, performed on this equipment. After the process of calibration of both detectors, they were placed side by side at a focus of the tube equipment for determining the performance of the same curve. Finally, using the curves generated by two detectors, INAK values of the 10 tests were calculated (from the kVp values, and mAs focus-patient of each exams), generating difference values at most 5%. As a conclusion, it can be said that the TLD lithium fluoride doped with Mg, Cu and P and the cylindrical ionization chambers may be used satisfactorily to determine the yield curve, whether as quality control or dosimetry

  5. Objective masurement of image quality in fluoroscopic x-ray equipment FluoroQuality

    CERN Document Server

    Tapiovaara, M

    2003-01-01

    The report describes FluoroQuality, a computer program that is developed in STUK and used for measuring the image quality in medical fluoroscopic equipment. The method is based on the statistical decision theory (SDT) and the main measurement result is given in terms of the accumulation rate of the signal-to-noise ratio squared (SNR sup 2 sub r sub a sub t sub e). In addition to this quantity several other quantities are measured. These quantities include the SNR of single image frames, the spatio-temporal noise power spectrum and the temporal lag. The measurement method can be used, for example, for specifying the image quality in fluoroscopic images, for optimising the image quality and dose rate in fluoroscopy and for quality control of fluoroscopic equipment. The theory behind the measurement method is reviewed and the measurement of the various quantities is explained. An example of using the method for optimising a specified fluoroscopic procedure is given. The User's Manual of the program is included a...

  6. Development of cancer medical treatment/diagnostic equipment using the source of X-rays in space coherence

    International Nuclear Information System (INIS)

    Sato, Isamu; Shintomi, Kazutaka; Hayakawa, Ken

    2009-01-01

    In Nihon University, the research and development of Parametric X-rays radiation (PXR) by the 100 MeV electron linac are advanced. It was proved by basic experiment that PXR was a source of coherent X-rays. Coherent X-rays have the characteristic that a refraction action is guided with an irradiation matter. According to this action, the contrast image pick-up of an irradiation matter is attained, and X-rays becomes possible to focus a point itself. Research of cancer medical treatment and diagnosis are advanced using the new source of X-ray. Miniaturization of the source is important for the spread of cancer medical new treatment and diagnoses. Recently, the tabletop type 100 MeV class cryogenic linac with energy recovery is under development. In symposium, we report progress of these research and development. (author)

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... knee, leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ... information about pregnancy and x-rays. top of page What does the equipment look like? The equipment typically ...

  8. Setting up processes and standardization of the equipment in order to optimize analyses of the wavelength dispersion X-ray fluorescence (WDXRF) system

    International Nuclear Information System (INIS)

    Phan Trong Phuc; Luu Anh Tuyen; La Ly Nguyen; Nguyen Thi Ngoc Hue; Pham Thi Hue; Do Duy Khiem

    2015-01-01

    For the purpose of operating and optimizing the analyses of the equipment: wavelength dispersion X-ray fluorescence (WDXRF)- model S8 TIGER from Enhancing Equipment Project (TCTTB) 2011-2012, we set up sampling and analytical process for different sample kinds; we constructed multi-elemental calibration curve for clay sample; we analysed elemental concentrations of 5 clay samples by XRF method and compared the results with the results given by NAA method. Equipment sensitivity was tested by analysing elemental concentrations of 2 Kaolin standard samples. The results show that S8-Tiger equipment is within good condition and is able to analyze powder clay sample exactly. (author)

  9. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures

    International Nuclear Information System (INIS)

    Bottaro, Marcio

    2012-01-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10 8 V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW ® platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  10. The tendency of medical electrical equipment - IEC 60601-2-54: Particular requirements for the basic safety and essential performance of x-ray equipment for radiography and radioscopy

    International Nuclear Information System (INIS)

    Roh, Young Hoon; Kim, Jung Min

    2015-01-01

    Medical electrical equipment - Part 1: General requirement for basic safety and essential performance of MFDS was revised as 3th edition and Medical electrical equipment Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment will be expected to be announced as notification. Therefore this technical report was written to introduce provision of the particular requirements, replacement, addition, amendment. The purpose of this particular requirements is to secure requirements for basic safety and essential performance of X-ray equipment for radiography and radioscopy. X-ray high voltage generator, mechanical protective device, protection against radiation is included in this particular requirements. Medical electrical equipment - Part 1, Part 1-2, Part 1-3 is applied to this particular requirements. If the requirements is announced as notification, It is expected to widen understanding for basic safety and essential performance of X-ray equipment for radiography and radioscopy and play a part to internationalize of medical equipment

  11. Radiometer evaluation of X-rays equipment in the region of Aracatuba, Sao Paulo, Brazil;Avaliacao radiometrica de raios-X na regiao de Aracatuba, Sao Paulo

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Marco A.R. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina; Kanezawa, Jorge S. [Centro de Ensino e Tecnologia de Aracatuba (CETEA), SP (Brazil)

    2009-07-01

    This paper presents the basic concepts of radiation protection to guide the health care professionals who use equipment emitting ionizing radiation on the correct handling of the beams of radiation. Radiometric evaluations were conducted in 1665 in X-ray equipment, installed in dental surgeries and clinics, hospitals and radiology services, during the years 1996 to 2003 in the region of Aracatuba. Tests of radiometry are presented as a technical report where the parameters are quantified physical and radiological verifying its compliance with the established by legislation. The distribution of reports by type of unit shows that the vast majority of equipment is of periapical dental x-rays (72%), 25% of equipment is medical equipment for radiology and 3% is dental equipment panoramic model (orthodontic documentation). Among the physical parameters analyzed, the length of the browser was showing more variance compared to the required by law, this fact may also contribute to gaps in the rate of the radiation dose and the size of field in the skin of the patient, the that can easily be resolved simply to replace the piece at the outlet of the head. During the completion of visits to services, it also noted a gap in the training of professionals who operate this equipment emitting radiation, warning of the need for specific training in the area. (author)

  12. Survey of medical X-ray centres in the municipal area of Munich to evaluate their technical equipments

    International Nuclear Information System (INIS)

    Dielschneider, K.

    1988-01-01

    Data were collected on the facilities and installations in various medical X-ray centres in the Munich municipal area that were to form the basis of a large-scales survey demanded by the EC Council. Questionnaires especially designed to serve that purpose were sent out to 550 adminstrative bodies maintaining X-ray centres and completed by 67.6% of these. It was evident from the survey that the firms Siemens, CHF Mueller, Hofmann, Picker and Koch and Sterzel are sharing the market between them, leaving only a small portion to a group of other suppliers. The majority of X-ray units were found to data from the period between 1971 and 1980, even though 7.4% were purchased before 1960 and have thus been in use for more than twenty years. Most generators still are of the six-pulse type, but hospitals in particular now appear to be showing a pre-dilection for twelve-pulse and multipulse generators. Special-purpose facilities are mostly encountered in clinics and similar institutions. Among these, devices for taking sectional roentgenograms prevail. The majority of fluoroscopes feature built-in spot-film devices, devices for image-intensified television and multi-leaf collimators. Most radiographic units come complete with cassette support, examining table and grid as well as multi-leaf collimators. The X-rays taken are generally processed by machine. The analysis led to the conclusion that the X-ray services available to the population of the Munich municipal area can be regarded as being very satisfactory. (orig./HP) [de

  13. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  14. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the patient in a hospital bed or the emergency room. The x-ray tube is connected to ... equipment is relatively inexpensive and widely available in emergency rooms, physician offices, ambulatory care centers, nursing homes ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... replacement and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in ... injuries, including fractures, and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely ...

  17. Image guided radiotherapy. Quality control of X ray equipment. S.F.P.M. report nr 29

    International Nuclear Information System (INIS)

    Delpon, Gregory; Aubignac, Leone; Bramoulle, Celine; Boutry, Christine; Guerin, Lucie; Lafay, Frederic; Benoit, David; Garcia, Robin; Jaegle, Enric; Vieillevigne, Laure; Dedieu, Veronique; Ferrrer, Ludovic; Guillhem, Marie-Therese; Lacaze, Brigitte; Mazurier, Jocelyne; Simon, Luc

    2014-01-01

    This report presents different X ray imagery systems used for positioning support in external radiation therapy, and installed in treatment rooms. If portal imagery systems and rail-mounted tomodensitometry systems are not addressed in this document, the authors distinguish and describe various embedded systems in which devices are directly mounted on the treatment apparatus (X-Ray Volume Imaging by Elekta, On Board Imager by Varian), peripheral systems which are independent from the machine (Cyberknife by Accuray and Exatrac by BrainLab), MVCT or Mega Voltage Computed Tomography systems (Tomotherapy by Accuray), and MVCBCT or Megavoltage Cone Beam Computed Tomography systems (Artiste by Siemens). After a brief presentation of these systems, the author present various aspects of quality controls (list, periodicity, test tolerance, tested objects), and then more precisely describe the above-mentioned systems. For each of them, the following aspects are addressed: generator, geometry, image quality, dose, environment and safety, gating module, quality controls

  18. Calibration of handheld X-ray fluorescence (XRF) equipment for optimum determination of elemental concentrations in sediment samples.

    Science.gov (United States)

    Mejía-Piña, K Gabriela; Huerta-Diaz, Miguel Angel; González-Yajimovich, O

    2016-12-01

    Handheld X-ray fluorescence spectrometers (XRFs) represent a more practical, efficient and economic tool to determine the elemental composition of solid inorganic and organic samples than conventional analytical techniques. The objective of this work was to demonstrate that handheld XRFs could be a precise, accurate and reliable tool to analyze up to 27 different elements. This objective was accomplished through the optimization of an empirical calibration curve that, in addition to include certified reference materials (CRM), it also introduced new approaches, such as the use of solid CRM mixtures and combinations of organic and inorganic matrices. These approaches significantly increased the number of calibration points and eliminated hiatuses in the calibration curve. Several factors were evaluated before construction of the calibration curve: incidence time of the X-ray beam, type of film through which the X-ray beams reach the samples, container type, minimum sample volume and sample moisture content. Results show that single elements can be analyzed with variable exposure times or, alternatively, multielemental analyses can be carried out with a constant exposure time (180s). Costs can be reduced by using Ziploc ® bags as sample containers, but the number of measurable elements drops from 27 to 21, while the possibility of contamination increases. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Evaluating performance characteristics of x-ray equipment and film systems without the use of electronic measurement and/or special instruments

    International Nuclear Information System (INIS)

    Bianchi, M.F.; DeNitto, C.; Liscio, A.; Scala, N.

    2004-01-01

    Measurement and control of characteristics of NDT equipment and system that produce output to be interpreted by inspector is one of the most important tools for NDT reliability. Control activity should be based on: initial accurate measurement and calibration; periodical check to assure maintenance of calibration status; and, immediate verification and corrective action when any malfunctioning is suspected. 'Self-calibration' intended as capability of NDT facility to calibrate and control its own equipment and systems is very important for continuous and reliable activity. Typical approach based on this philosophy is ASTM E317 'Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Examination Instruments and Systems Without the Use of Electronic Measurement Instruments' that is applicable to shop or field conditions. Is 'Self-calibration' applicable to radiographic system too? Many characteristics can be self-determined according to existing practices and methods, but other ones require assistance and cooperation of supplier both for film system and x-ray equipment. A certified film system being controlled by pre-exposed filmstrips can be adopted as 'measurement device' for X-ray output concerning both intensity and contrast. Basically x-ray equipment manufacturer performs initial accurate measurement and calibration using electronic measurement and/or special instrumentation as necessary. Then specific film set on 'low-price' blocks and specimens is produced according to standard practice whose guidelines are supplied by this paper. Film set, blocks, specimens and results referred to specific film system will be the reference kit for periodical check in NDT facility. This paper supplies some guidelines for standard practice based on testing using mainly GE Inspection Technologies radiographic system being available in Avio facilities. (author)

  20. Licensing of non intrusive inspection equipment s for load and passengers vehicles that use X rays with energies up to 9 MeV. Mexican experience

    International Nuclear Information System (INIS)

    Munoz M, G. A.; Jimenez C, I.

    2013-10-01

    In the last years and like part of the extensive program of national security, in Mexico have been introduced a great quantity of non intrusive inspection equipment s for load and passengers vehicles that use X rays up to 9 MeV. Due to the great variety of equipment s, the Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexican regulator organ) has established specific guidelines for their licensing and use supervision. In this work the adopted guidelines are exposed in the technical and administrative evaluation for the later licensing of these equipment s. Relative particular questions to the site of these equipment s and the impact in the public opinion that their use can generate are discussed. (author)

  1. Calibration voltage test of non invasive meter for radiodiagnostic on equipment of constant potential X-ray; Teste de calibracao de medidor nao invasivo de tensao para radiodiagnostico em equipamentos de raios X de potencial constante

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P., E-mail: mmoramos@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Pereira, Marco A.G.S., E-mail: guedes@iee.usp.b [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia; Lopes, Ricardo T., E-mail: ricardo@lin.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil)

    2009-07-01

    This work evaluates the utilization of the non invasive voltage meter PTW Diavolt Universal in industrial X ray equipment of constant potential. With the performed measurements, the conclusion is that conclusion is possible, once his use limits are identified

  2. Case study of a traditional material (adobe) for facilities design destined to X-ray equipment emplacement

    International Nuclear Information System (INIS)

    Aguilar Serrano, Lola

    2008-01-01

    The objective of this work is to use the existent material (adobe) in the national market as an alternative for an optimum design that counts with the conditions for radiological protection as well as an adequate infrastructure to service assistance. Therefore, it gives a tool of professional use for an X-ray installation design, because the adobes represent an adequate protection for employees as Worker occupational exposed (WOE) and for general public, also for economics reasons and construction technical aspects. With the study of above material is demonstrated that in X-ray facilities construction is not always necessary the use of lead sheets or another materials for walls, which are used as shielding elements against ionizing radiation. The adobe election for this study, is because Bolivia counts with a great percentage of constructed areas whit this type of material because is economical and raw material is accessible for users. From the experimental tests we get the graphics that allow to found the half value thickness (HVT) of the half layer (HVL) of this adobe, is that thickness of material with when placed in the path of the radiation will attenuate it to one half its original value. A tenth value thickness (TVT) similarly reduces the radiation to one tenth of its original value. Material which contains heavy atoms and molecules such as steel and lead provide the most effective (thinnest) shields for X-rays. The contribute of this study, carried out with the construction material (adobe) that exists in the national market will be of great utility for society because there is no values recorded in the bibliography. (author)

  3. Results of the technical evaluation of dentistry X-ray equipment of a faculty of Dentistry of Rio Grande do Sul State, based on Regulation 453 of Health Ministry and IRD/CNEN-BR recommendations

    International Nuclear Information System (INIS)

    Staevie, G.L.G.; Jahn, T.R.; Barbieri, D.X.; Mas, C.R Dal; Sbaraini, P.; Saba, J.C.P.

    2001-01-01

    This paper describes the technical evaluation of odontology X-ray equipment installed in a local school of odontology with regard to the fulfillment of requirements of Regulation No. 453, issued by Brazilian Ministry of Health and the recommendations of the Institute of Radiation Protection and Dosimetry, IRD/CNEN. Fifteen intra-oral odontology X-ray equipment were evaluated and their conformities and non-conformities were identified, followed by recommendations to be adopted by the school. (author)

  4. Time- and wavelength-resolved luminescence evaluation of several types of scintillators using streak camera system equipped with pulsed X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, Yuki, E-mail: f.yuki@mail.tagen.tohoku.ac.j [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Yanagida, Takayuki; Fujimoto, Yutaka; Yokota, Yuui; Kamada, Kei [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Kawaguchi, Noriaki [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Research and Development Division, Tokuyama., Co. Ltd., ICR-Building, Minamiyoshinari, Aoba-ku, Sendai (Japan); Ishizu, Sumito [Research and Development Division, Tokuyama., Co. Ltd., ICR-Building, Minamiyoshinari, Aoba-ku, Sendai (Japan); Uchiyama, Koro; Mori, Kuniyoshi [Hamamatsu Photonics K.K., 325-6, Sunayama-cho, Naka-ku, Hamamatsu, Shizuoka 430-8587 (Japan); Kitano, Ken [Vacuum and Optical Instruments, 2-18-18 Shimomaruko, Ota, Tokyo 146-0092 (Japan); Nikl, Martin [Institute of Physics ASCR, Cukrovarnicka 10, Prague 6, 162-53 (Czech Republic); Yoshikawa, Akira [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); NICHe, Tohoku University, 6-6-10 Aoba, Aramaki, Aoba-ku, Sendai 980-8579 (Japan)

    2011-04-01

    To design new scintillating materials, it is very important to understand detailed information about the events, which occurred during the excitation and emission processes under the ionizing radiation excitation. We developed a streak camera system equipped with picosecond pulsed X-ray source to observe time- and wavelength-resolved scintillation events. In this report, we test the performance of this new system using several types of scintillators including bulk oxide/halide crystals, transparent ceramics, plastics and powders. For all samples, the results were consistent with those reported previously. The results demonstrated that the developed system is suitable for evaluation of the scintillation properties.

  5. X-ray diffraction

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of literature on X-ray diffraction begins with a list of conference proceedings on the subject, organised by the Philips' organisation at regular intervals in various European countries. This is followed by a list of bulletins. The bibliography is divided according to the equipment (cameras, diffractometers, monochromators) and its applications. The applications are subdivided into sections for high/low temperature and pressure, effects due to the equipment, small angle scattering and a part for stress, texture and phase analyses of metals and quantitative analysis of minerals

  6. 171 ROYAL DECREE 1891/1991 of 30 December 1991 on the installation and use of X-ray equipment for the purposes of medical diagnosis

    International Nuclear Information System (INIS)

    1992-01-01

    The Decree lays down the rules enabling government authorities to monitor the proper functioning of such appliances. It takes account of the Council of European Communities' Directive 80/836/Euratom amended by Directive 84/466/Euratom on basic safety standards for the health protection of the general public and workers against the dangers of ionization and Directive 84/467/Euratom laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. The Decree provides for a register of firms authorised to sell and maintain medical X-ray equipment, and a register of the equipment installed. It also sets out requirements relating to third party liability insurance, and to the qualifications and training of personnel operating the equipment. (NEA)

  7. Evaluation of medical exposure and exposure by the public in a typical scenario of examinations using mobile X-ray equipment through the Monte Carlo simulation

    International Nuclear Information System (INIS)

    Santos, Felipe A.; Galeano, Diego C.; Santos, William S.; Carvalho Júnior, Albérico B.

    2016-01-01

    In this work irradiation scenarios that simulated chest and abdomen examinations involving mobile X-ray equipment in hospitals were modeled with the purpose of calculating conversion coefficient for effective dose (CC E ), normalized to entrance surface dose (ESD), applied to patients and public individuals. These coefficients can easily be used in this practice. Patients and public individuals were represented by a pair of anthropomorphic phantoms inserted in the MCNPX 2.7.0 radiation transport code. One of the phantoms (patient) was irradiated with the direct beam simulating examinations of the chest and abdomen, each with two fields of irradiation, ideal (IF) and extrapolated (EF). Using the software SPECGEN X-ray spectra from 60 to 100 kVp at 10 kVp intervals were generated and used in this work. The other phantom (public individual) was positioned 50–200 cm from the patient. In relation to the CC E calculated in the patient, the average increase obtained between the irradiation fields was 62.4% for the chest examinations, and for the same conditions the CC E was calculated for abdomen examinations and found to be 8.0%. Increasing the distance between public individual and patient, reductions of up to 81.7% in the CC E in abdomen examinations and 83.4% in chest examinations were observed. Through the assessment of CC E of these scenarios, it is possible to measure the damages relating to this practice for both patients and public individuals. - Highlights: • A computational scenario involving mobile X-ray equipment in hospitals were modeled. • Evaluation of medical exposure and exposure by the public was made by CC E (E/ESD). • A pair of the anthropomorphic simulators was inserted into the input file MCNPX. • Analyze the influence in CC E for the different types of fields used in examinations. • Monitoring the reduction of CC E 's with increasing distance between the beds.

  8. Cosmic x ray physics

    Science.gov (United States)

    Mccammon, Dan; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1991-01-01

    The annual progress report on Cosmic X Ray Physics for the period 1 Jan. to 31 Dec. 1990 is presented. Topics studied include: soft x ray background, new sounding rocket payload: x ray calorimeter, and theoretical studies.

  9. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  10. Chest x-ray

    Science.gov (United States)

    Chest radiography; Serial chest x-ray; X-ray - chest ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  11. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  12. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  13. Improvement in the clinical practicability of roentgen stereophotogrammetric analysis (RSA): free from the use of the dual X-ray equipment.

    Science.gov (United States)

    Shih, Kao-Shang; Lee, Chian-Her; Syu, Ci-Bin; Lai, Jiing-Yih; Chen, Kuo-Jen; Lin, Shang-Chih

    2012-10-01

    After total knee replacement, the monitoring of the prosthetic performance is often done by roentgenographic examination. However, the two-dimensional (2D) roentgen images only provide information about the projection onto the anteroposterior (AP) and mediolateral (ML) planes. Historically, the model-based roentgen stereophotogrammetric analysis (RSA) technique has been developed to predict the spatial relationship between prostheses by iteratively comparing the projective data for the prosthetic models and the roentgen images. During examination, the prosthetic poses should be stationary. This should be ensured, either by the use of dual synchronized X-ray equipment or by the use of a specific posture. In practice, these methods are uncommon or technically inconvenient during follow-up examination. This study aims to develop a rotation platform to improve the clinical applicability of the model-based RSA technique. The rotation platform allows the patient to assume a weight-bearing posture, while being steadily rotated so that both AP and ML knee images can be obtained. This study uses X-ray equipment with a single source and flat panel detectors (FPDs). Four tests are conducted to evaluate the quality of the FPD images, steadiness of the rotation platform, and accuracy of the RSA results. The results show that the distortion-induced error of the FPD image is quite minor, and the prosthetic size can be cautiously calibrated by means of the scale ball(s). The rotation platform should be placed closer to the FPD and orthogonal to the projection axis of the X-ray source. Image overlap of the prostheses can be avoided by adjusting both X-ray source and knee posture. The device-induced problems associated with the rotation platform include the steadiness of the platform operation and the balance of the rotated subject. Sawbone tests demonstrate that the outline error, due to the platform, is of the order of the image resolution (= 0.145 mm). In conclusion, the rotation

  14. Evaluation of conventional x-ray diagnostic equipment and radiological protection systems of hospitals and clinics installed in Recife city, Brazil

    International Nuclear Information System (INIS)

    Passos, Robson Silva

    1999-05-01

    Diagnostic radiology is the main contributor to the man-made exposure of general population. Since Quality Assurance (QA) programs ensure high quality diagnostic images with the lowest possible radiation dose to the patient, it has been recommended that all introduce QA programs for their radiological facilities. Consequently it is important to check the adequacy of equipment operating parameters in diagnostic radiography facilities, to ensure that a high quality of service is delivered. The purpose of this study was to evaluate the operating conditions of diagnostic units installed in Recife, Pernambuco. The study included 31 X-ray units from both public and private diagnostic services. The following parameters were evaluated: coincidence between the luminous and radiation fields; alignment of the radiation beam; agreement between the real and preset values of kVp and exposure time; filtration; half value lower (HVL); luminance of the view box; uniformity of the luminance; illuminance of the environment. The results showed that 20% of the equipment surveyed exhibited discrepancies between the luminous and radiation fields greater than 2% of the source to skin distance. The test of kilovoltage showed that 48% of the units do not fulfill the acceptability criteria, presenting discrepancies higher than ± 10% between the measured and preset values. The results of the accuracy of the timer indicated that 81% of the equipment surveyed present a discrepancy greater than ± 10% between the time selected in the control panel and actual exposure time.The test of the filtration shown that, in 20% of the equipment, this was inferior to 2,5 mm Al. The test of the luminance of view box shown that 96% of the equipment, shown a luminance lower of 2.000 cd/m 2 . Related to the test of the uniformity of the luminance, 81 % of the equipment shown a variation of the uniformity higher then 10%. The test of the iluminancy of the environment shown that 61 % of the equipment presented

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  16. Flash x-ray cinematography

    International Nuclear Information System (INIS)

    Stein, W.E.

    1976-01-01

    Experiments intended to provide an overview of the potential capabilities and limitations of flash x-ray cinematography as a diagnostic technique for a Fast Reactor Safety Test Facility are described. The results provide estimates of the x-ray pulse intensity required to obtain adequate radiographs of an array of fuel pins in a typical reactor configuration. An estimate of the upper limit on the pulse duration imposed by the reactor background radiation was also determined. X-ray cinematography has been demonstrated at a repetition rate limited only by the recording equipment on hand at the time of these measurements. These preliminary results indicate that flash x-ray cinematography of the motion of fuel in a Fast Reactor Test Facility is technically feasible

  17. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  18. The critical examination of X-ray generating equipment in diagnostic radiology. Guidance on the interpretation of the Ionising Radiation Regulations 1985, Regulation 32(2)a

    International Nuclear Information System (INIS)

    1998-01-01

    Regulation 32(2)a requires an examination, where appropriate, of X-ray equipment and its operating environment, following its installation, repair or modification. In this context 'appropriate' means - 'if there are possible radiation protection implications'. The examination should be carried out before the equipment is brought into use. The intent of the Regulation is to ensure that the installation process does not compromise the radiation safety of the equipment as provided for by its original design and manufacture, and that any persons who might be exposed are adequately protected. However, the scope of the Regulation does not directly cover features controlling the optimisation of dose for a medical exposure. An examination of the equipment relating to the radiation protection consequences of the way it was installed is required. This is termed 'critical', emphasising the need to review the installation to a greater degree than the simple fulfilment of a preconceived test procedure. The involvement of a radiation protection adviser is required as an expert in radiation safety. This document provides guidance on when it is necessary to carry out a critical examination, and on its content. The Ionising Radiations Regulations 1985 firmly place the responsibility for ensuring that a critical examination is carried out, on the installer of the equipment. However, knowledge of various aspects of the critical examination is also relevant to employers who manage health related facilities, as well as their RPAs, and physicists who carry out equipment tests. Aside from the actual examination itself, there are issues pertaining to purchase contracts, and a knowledge of the satisfactory completion of a critical examination will be relevant to an employer in fulfilling his duties under Regulations 6 and 33. (author)

  19. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  20. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  1. Dental x-rays

    Science.gov (United States)

    X-ray - teeth; Radiograph - dental; Bitewings; Periapical film; Panoramic film; Digital image ... dentist's office. There are many types of dental x-rays. Some of them are: Bitewing. Shows the crown ...

  2. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  3. X-ray (image)

    Science.gov (United States)

    X-rays are a form of ionizing radiation that can penetrate the body to form an image on ... will be shades of gray depending on density. X-rays can provide information about obstructions, tumors, and other ...

  4. Radiation protection in dentistry. Recommended safety procedures for the use of dental x-ray equipment. Safety code 30

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has prepared a series of documents on safety codes to set out requirements for the safe use of radiation-emitting equipment. This Safety Code has been prepared to provide specific guidance to the dentist, dental hygienist, dental assistant and other support personnel concerned with safety procedures and equipment performance. Dental radiography is one of the most valuable tools used in modern dental health care. It makes possible the diagnosis of physical conditions that would otherwise be difficult to identify. The use of dental radiological procedures must be carefully managed, because x-radiation has the potential for damaging healthy cells and tissues. Although no known occurrence of cancer or genetic damage has been observed from radiation doses delivered in modern dentistry, and until more evidence is available, one should practice radiation hygiene with the same care as would be dictated if a hazard were known to exist. The aim of radiation protection in dentistry is to obtain the desired clinical information with minimal radiation exposure to patients, dental personnel and the public. 15 tabs

  5. Switching X-Ray Tubes Remotely

    Science.gov (United States)

    Bulthuis, Ronald V.

    1990-01-01

    Convenient switch and relay circuit reduces risk of accidents. Proposed switching circuit for x-ray inspection system enables operator to change electrical connections to x-ray tubes remotely. Operator simply flips switch on conveniently-located selector box to change x-ray heads. Indicator lights on selector box show whether 160 or 320-kV head connected. Relays in changeover box provides proper voltages and coolants. Chance of making wrong connections and damaging equipment eliminated.

  6. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of Literature on x-ray fluorescence spectrometry starts with a list of conference proceedings on the subject, organised by the Philips organisation at regular intervals in various European countries. It is followed by a list of bulletins. The bibliography is subdivided according to spectra, equipment, applications and absorption analysis

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the equipment look like? How does the procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of Bone X-ray ( ...

  8. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  9. The Beginnings of X-ray Crystallography

    Indian Academy of Sciences (India)

    IAS Admin

    broke his arm when he was 5 years old and his father used the newly discovered Rontgen-rays. (X-rays) and his experimental equipment to examine the broken arm, which is the first recorded surgical use of X-rays in Australia. William Lawrence Bragg married Alice Hopkinson (1899–. 1989) in 1921, with whom he had four ...

  10. Analysis of Pre-Columbian objetcs from Cupisnique, one of the oldest culture from Perú, using a portable X-ray fluorescence equipment

    Science.gov (United States)

    Bustamante, A.; Cesareo, R.; Brunetti, A.; Rizzutto, M.; Calza, C.; Pereira de Freitas, R.; Holmsquit, U.; Diestra, D.

    2013-12-01

    Cupisnique (2000-200 BC) is one of the first complex societies that developed in the Jetequepeque valley in the "Formative period." It includes several settlements: Puémape on the coast, Limoncarro in middle valley, Montegrande and Tembladera in the upper valley, and Kuntur Wasi in San Pablo. Currently the valley comprises two provinces, Pacasmayo and Chepen in the La Libertad region, north of Lima. Consideration should be given to cupisniques as premetallurgical culture, and the only used metal was gold, which is present in the native state, on the soil surface or shallow, and attracted attention because of color, brightness, weight, ductility, and inalterability. We analyzed three Cupisnique metal objects belonging to the Larco Museum of Lima designated with No. 4 (pectoral), No. 7 (pendant), and No. 12 (bracelet), using a portable energy-dispersive X-ray fluorescence equipment. Mean value for the pectoral were Au (62 %), Ag (23 %), Cu (15 %); for the pendant, Au (81 %), Ag (16.5 %), Cu (2.5 %); and for the bracelet, Au (69.1 %), Ag (20 %), and Cu (10.9 %).

  11. Los Alamos Scientific Laboratory x-ray survey manual

    International Nuclear Information System (INIS)

    Olsher, R.H.

    1980-02-01

    A manual has been developed by the Health Physics Group to establish procedures for routine testing of industrial and analytical x-ray equipment for compliance with applicable LASL administrative requirements and technical bulletins. Radiation protection survey procedures were developed for the following types of equipment: x-ray diffraction and fluorescence analysis systems, industrial cabinet x-ray systems, industrial noncabinet x-ray systems, and electron microscopes

  12. X-ray holography

    CERN Document Server

    Faigel, G; Belakhovsky, M; Marchesini, S; Bortel, G

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples.

  13. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  14. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  15. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... loose, comfortable clothing. You may be asked to change into a gown. You may have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny ...

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  18. X-ray tube transformer

    International Nuclear Information System (INIS)

    1980-01-01

    An X-ray generator is described which comprises a transmission line transformer including an electrical conductor with a cavity and a second electrical conductor including helical windings disposed along a longitudinal axis within the cavity of the first conductor. The windings have a pitch which varies per unit length along the axis. There is dielectric material in the cavity for insulation and to couple electromagnetically the two conductors in response to an electric current flowing through the conductors, which have an impedance between them; this varies with distance along the axis of the helix of the second conductor. An X-ray tube is disposed along the longitudinal axis within the cavity, for radiating X-rays. The invention increases the voltage of applied voltage pulses at the remote tube-head with a transformer formed by using a spiral delay line geometry to give a tapered-impedance coaxial high voltage multiplier for pulse voltage operation. This transformer is smaller and lighter than previous designs for the same high peak voltage and power ratings. This is important because the penetration capabilities of Flash X-ray equipment increase with voltage, particularly in heavy materials such as steel. (U.K.)

  19. X-ray diagnostics in non-specialized conditions

    International Nuclear Information System (INIS)

    Vasil’yev, A Y; Lyubimenko, V A; Potrakhov, Y N; Potrakhov, N N; Bessonov, V B; Klonov, V V; Larionov, I A; Gryaznov, A Y; Zhamova, K K

    2017-01-01

    The results of research in the development of X-ray diagnostic equipment in non-specialized conditions are described. The design of the first domestic digital X-ray diagnostic complex for neonatology in portable design is presented. Examples of X-ray images obtained “at home” from a patient are given. (paper)

  20. X-ray generator

    International Nuclear Information System (INIS)

    Dawson, J.M.

    1976-01-01

    An apparatus and a method are described for producing coherent secondary x-rays that are controlled as to direction by illuminating a mixture of high z and low z gases with an intense burst of primary x-rays. The primary x-rays are produced with a laser activated plasma, and these x-rays strip off the electrons of the high z atoms in the lasing medium, while the low z atoms retain their electrons. The neutral atoms transfer electrons to highly excited states of the highly stripped high z ions giving an inverted population which produces the desired coherent x-rays. In one embodiment, a laser, light beam provides a laser spark that produces the intense burst of coherent x-rays that illuminates the mixture of high z and low z gases, whereby the high z atoms are stripped while the low z ones are not, giving the desired mixture of highly ionized and neutral atoms. Means for magnetically confining and stabilizing the plasma are disclosed for controlling the direction of the x-rays

  1. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  2. X-ray detector

    International Nuclear Information System (INIS)

    Whetten, N.R.; Houston, J.M.

    1977-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of x-ray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes. 8 figures

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  4. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small ... limitations of Panoramic X-ray? What is Panoramic X-ray? Panoramic radiography , also called panoramic x-ray , is ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  6. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  7. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  8. X-Ray Exam: Hip

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: ... darker. An X-ray technician takes the X-rays. An X-ray technician in the radiology department of a ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  10. Lumbosacral spine x-ray

    Science.gov (United States)

    X-ray - lumbosacral spine; X-ray - lower spine ... The test is done in a hospital x-ray department or your health care provider's office by an x-ray technician. You will be asked to lie on the x-ray table ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  12. Chest X-Ray

    Medline Plus

    Full Text Available ... Radiology and You Take our survey Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  13. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... Site Index A-Z Spotlight February is American Heart Month Recently posted: Carotid Intima-Media Thickness Test ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... Abdominal Ultrasound Video: Pelvic Ultrasound Medical Imaging Costs Radiology and You Take our survey Sponsored by Image/ ... Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... exams and use a very small dose of ionizing radiation to produce pictures of the inside of the ... chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... accurate diagnosis far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... and You Take our survey Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript ... Carotid Intima-Media Thickness Test Medical Imaging Costs Video: Abdominal Ultrasound Video: Pelvic Ultrasound Radiology and You ...

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs any risk. ...

  20. Chest X-Ray

    Medline Plus

    Full Text Available ... chest x-ray is used to evaluate the lungs, heart and chest wall and may be used ... diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A ...

  1. Chest X-Ray

    Medline Plus

    Full Text Available ... and use a very small dose of ionizing radiation to produce pictures of the inside of the ... x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  2. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight March is National Colorectal Cancer Awareness Month Recently posted: Carotid Intima-Media Thickness ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight March is National Colorectal Cancer Awareness Month Recently posted: How to Obtain and ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight March is National Colorectal Cancer Awareness Month Recently posted: Video: The Basketball Game: ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  5. X-Ray Lasers

    Science.gov (United States)

    Eder, David C.

    1998-05-01

    We provide an overview of the status of x-ray laser development worldwide with particular attention given to activities at LLNL. Since the demonstration of x-ray lasing 14 years ago there has been major progress in achieving shorter wavelengths, higher energies per pulse, higher efficiency, shorter pulse durations, etc. Original x-ray lasers used large kJ class lasers to achieve lasing in mid-Z materials with electron collisional pumping in the highly stripped ion being the most successful process for populating the upper-laser state. The two most common electron configurations for these collisional x-ray lasers are Ne-like and Ni-like ions. Through the use of prepulses and short picosecond driving pulses, transient collisional x-ray lasing schemes have been demonstrated using lasers with only a few Joules per pulse. An interesting aspect of these lasers is the time lag in reaching ionization equilibrium helps in obtaining high gain coefficients. A different approach to x-ray lasing is also being studied where lasing occurs in a singly ionized ion following innershell photoionization. The major requirement of the driving laser in this case is an ultrashort pulse duration (rise time to achieve lasing prior to collisional ionization of outershell electrons. In the area of applications, most of the work has been for single pulse experiments such as plasma and biological imaging. However, many of the new x-ray lasers achieve high average power by having a reasonable repetition rate of order 10 Hz and we briefly discuss relevant applications for these x-ray lasers. This work performed under the auspices of US DOE by LLNL under Contract No. W-7405-Eng-48.

  6. X-Ray Optics

    Science.gov (United States)

    1990-01-01

    samples. Another exciting application of microbeam of x-rays is in that of high pressure x-ray diffraction from small samples. Along this line, Yan...will be presented by Jonathan in February at the Physics and Chemistry of Semiconductor Interfaces conference and in March at the American Physical...VUV9 conference this summer. Jeff has also worked on developing software that makes use of the scattering factor tables for both microvax and IBM PC

  7. Time and wavelength-resolved luminescence evaluation of several types of scintillators using streak camera system equipped with pulsed X-ray source

    Czech Academy of Sciences Publication Activity Database

    Furuya, Y.; Yanagida, T.; Fujimoto, Y.; Yokota, Y.; Kamada, K.; Kawaguchi, N.; Ishizu, S.; Uchiyama, K.; Mori, K.; Kitano, K.; Nikl, Martin; Yoshikawa, A.

    2011-01-01

    Roč. 634, č. 1 (2011), s. 59-63 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10100521 Keywords : streak camera system * scintillator * pulsed X-ray source Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.207, year: 2011

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of knee x-rays. A portable x-ray machine is a compact apparatus that can be taken ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... holds the x-ray film or image recording plate . Sometimes the x-ray is taken with the ... an x-ray film holder or image recording plate is placed beneath the patient. top of page ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  14. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  15. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Setti, G.

    1980-01-01

    This book contains the lectures, and the most important seminars held at the NATO meeting on X-Ray astronomy in Erice, July 1979. The meeting was an opportune forum to discuss the results of the first 8-months of operation of the X-ray satellite, HEAO-2 (Einstein Observatory) which was launched at the end of 1978. Besides surveying these results, the meeting covered extragalactic astronomy, including the relevant observations obtained in other portions of the electromagnetic spectrum (ultra-violet, optical, infrared and radio). The discussion on galactic X-ray sources essentially covered classical binaries, globular clusters and bursters and its significance to extragalactic sources and to high energy astrophysics was borne in mind. (orig.)

  16. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  17. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: ... Ray Exam: Hip Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  18. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  19. X-Ray Exam: Foot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  20. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  1. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  2. X-Ray Exam: Finger

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  3. Subluminous X-ray binaries

    NARCIS (Netherlands)

    Armas Padilla, M.

    2013-01-01

    The discovery of the first X-ray binary, Scorpius X-1, by Giacconi et al. (1962), marked the birth of X-ray astronomy. Following that discovery, many additional X-ray sources where found with the first generation of X-ray rockets and observatories (e.g., UHURU and Einstein). The short-timescale

  4. X-ray detector

    International Nuclear Information System (INIS)

    Houston, J.M.; Whetten, N.R.

    1981-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of xray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes

  5. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  6. Flash x-ray

    International Nuclear Information System (INIS)

    Johnson, Q.; Pellinen, D.

    1976-01-01

    The complementary techniques of flash x-ray radiography (FXR) and flash x-ray diffraction (FXD) provide access to a unique domain in nondestructive materials testing. FXR is useful in studies of macroscopic properties during extremely short time intervals, and FXD, the newer technique, is used in studies of microscopic properties. Although these techniques are similar in many respects, there are some substantial differences. FXD generally requires low-voltage, line-radiation sources and extremely accurate timing; FXR is usually less demanding. Phenomena which can be profitably studied by FXR often can also be studied by FXD to permit a complete materials characterization

  7. X-ray image intensifier photography

    International Nuclear Information System (INIS)

    Richter, K.; Angerstein, W.; Steinhardt, L.

    1980-01-01

    The present treatise on X-ray image intensifier photography starts with introductory remarks on the history of X-ray imaging and image intensifiers. In the physical-technological part especially the quality of image and the methods of its measurement are discussed in detail. The relevant equipment such as image intensifier cameras, X-ray television, video recorder and devices of display and evaluation of images are presented as well as problems of radiation doses and radiation protection. Based on 25,000 examinations of the digestive, the biliary and the urinary tract, resp., as well as of the blood vessels the applicability of the X-ray image intensifier photography and its diagnostic value are demonstrated in the medical part of the book

  8. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  9. CRL X-RAY TUBE

    OpenAIRE

    Kolchevsky, N. N.; Petrov, P. V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed.

  10. X rays and condensed matter

    International Nuclear Information System (INIS)

    Daillant, J.

    1997-01-01

    After a historical review of the discovery and study of X rays, the various interaction processes between X rays and matter are described: Thomson scattering, Compton scattering, X-photon absorption through photoelectric effect, and magnetic scattering. X ray sources such as the European Synchrotron Radiation Facility (ESRF) are described. The various X-ray applications are presented: imagery such as X tomography, X microscopy, phase contrast; X-ray photoelectron spectroscopy and X-ray absorption spectroscopy; X-ray scattering and diffraction techniques

  11. Portable X-ray fluorescence analyzer of high sensitivity using X-ray tube excitation

    International Nuclear Information System (INIS)

    Vatai, E.; Ando, L.

    1982-01-01

    A review of the three main methods of X-ray fluorescence analysis and their problems is given. The attainable accuracy and effectiveness of each method are discussed. The main properties of portable X-ray analyzers required by the industry are described. The results and experiences of R and D activities in ATOMKI (Debrecen, Hungary) for developing portable X-ray analyzers are presented. The only way for increasing the accuracy and decreasing the measuring time is the application of X-ray tube excitation instead of radioactive sources. The new ATOMKI equipment presently under construction and patenting uses X-ray tube excitation; it will increase the accuracy of concentration determination by one order of magnitude. (D.Gy.)

  12. X-ray beam generator

    International Nuclear Information System (INIS)

    Koller, T.J.; Randmer, J.A.

    1977-01-01

    A method of minimizing the preferential angular absorption of the divergent beam from an X-ray generator is described. The generator consists of an X-ray shielded housing with an X-ray transmissive window symmetrically placed in radial alignment with a focal spot area on a sloped target surface of an X-ray tube in the housing. The X-ray tube may be of the stationary anode type or of the rotating anode type. (U.K.)

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... to consider the likelihood of benefit to your health. While a chest x-ray use a tiny ...

  14. Evaluation of absorbed radiation dose rate in a didactic X-ray equipment; Avaliacao da taxa de dose absorvida em um equipamento de raios-X didatico

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Phelipe Amaral Ferreira; Perini, Ana Paula; Neves, Lucio Pereira, E-mail: lucio.neves@ufu.br [Universidade Federal de Uberlandia (UFU), MG (Brazil). Instituto de Fisica

    2016-07-01

    This work was performed in order to create a new didactic experiment in the X-ray apparatus of PHYWE, where the saturation current was obtained through a free air ionization chamber. The values of saturation currents were obtained in two ways. Initially, the anodic DDP was kept constant and the anodic current was varied. In the second way, the anodic current was kept constant while the anodic DDP was varied. Therefore, we were able to evaluate the dependence of the absolved dose rate in relation to the DDP and the tube current. (author)

  15. X-ray safety at the Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Gutierrez, J.A.

    1986-11-01

    An organized and structured safety program for x-ray generating devices was initiated in October, 1979. An X-ray Device Control Office was established to manage the program that currently oversees the activities of 201 x-ray generating devices and to provide SOP reviews, perform shielding calculations, and provide training for both the operators and health physics x-ray device surveyors. The new program also establishes controls for procurement of new equipment, requires the writing of Standard Operating Procedures, requires training for operators and provides routine and non-routine safety inspections of x-ray generating devices. Prior to this program going into effect, the Laboratory had recorded nine documented x-ray related exposure accidents. Since then, there have been none. Program elements and experiences of interest to other x-ray device users are discussed. 3 refs

  16. X-ray filter for x-ray powder diffraction

    Science.gov (United States)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.; Dooryhee, Eric; Ghose, Sanjit

    2018-01-23

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and walls defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.

  17. X-ray refractometer

    International Nuclear Information System (INIS)

    Tur'yanskij, A.G.; Pirshin, I.V.

    2001-01-01

    Paper introduces a new circuit of X-ray refractometer to study angular and spectral features of refracted radiation within hard X-ray range. Refractometer incorporates two goniometers, two crystal-analyzers and three radiation detectors. The maximum distance between radiation source focal point and a receiving slit of the second goniometer is equal to 1.4 m. For the first time one obtained refraction patterns of fine-film specimens including C/Si stressed structure. Paper describes a new technique of refractometry via specimen oscillation at fixed position of a detecting device. Paper presents the measurement results of oscillation refraction patterns for specimens of melted quartz and ZnSe single crystal [ru

  18. X-ray microtomography

    International Nuclear Information System (INIS)

    Dunsmuir, J.H.; Ferguson, S.R.; D'Amico, K.L.; Stokes, J.P.

    1991-01-01

    In this paper the authors describe the application of a new high-resolution X-ray tomographic microscope to the study of porous media. The microscope was designed to exploit the properties of a synchrotron X-ray source to perform three dimensional tomography on millimeter sized objects with micron resolution and has been used in materials science studies with both synchrotron and conventional and synchrotron sources will be compared. In this work the authors have applied the microscope to measure the three dimensional structure of fused bead packs and berea sandstones with micron resolution and have performed preliminary studies of flow in these media with the microscope operated in a digital subtraction radiography mode. Computer graphics techniques have been applied to the data to visually display the structure of the pore body system. Tomographic imaging after flow experiments should detect the structure of the oil-water interface in the pore network and this work is ongoing

  19. Portable flash X-ray systems: applications and techniques

    International Nuclear Information System (INIS)

    Bryant, L.E.

    1976-01-01

    Three portable flash x-ray equipments are described, and applications such as jet and high explosive studies, bullet impact and lead casting experiments are given as well as techniques for triggering and protection of equipment and film

  20. X-ray Ordinance

    International Nuclear Information System (INIS)

    Kramer, R.; Zerlett, G.

    1983-01-01

    This commentary, presented as volume 2 of the Deutsches Strahlenschutzrecht (German legislation on radiation protection) deals with the legal provisions of the ordinance on the protection against harmful effects of X-radiation (X-ray Ordinance - RoeV), of March 1, 1973 (announced in BGBl.I, page 173), as amended by the ordinance on the protection against harmful effects of ionizing radiation, of October 13, 1976 (announced in BGBl. I, page 2905). Thus volume 2 completes the task started with volume 1, namely to present a comprehensive view and account of the body of laws governing radiation protection, a task which was thought useful as developments in the FRG led to regulations being split up into the X-ray Ordinance, and the Radiation Protection Ordinance. In order to present a well-balanced commentary on the X-ray Ordinance, it was necessary to discuss the provisions both from the legal and the medical point of view. This edition takes into account the Fourth Public Notice of the BMA (Fed. Min. of Labour and Social Affairs) concerning the implementation of the X-ray Ordinance of January 4, 1982, as well as court decisions and literature published in this field, until September 1982. In addition, the judgment of the Federal Constitutional Court, dated October 19, 1982, concerning the voidness of the law on government liability, and two decisions by the Federal High Court, dated November 23, 1982, concerning the right to have insight into medical reports - of great significance in practice - have been considered. This commentary therefore is up to date with current developments. (orig.) [de

  1. X-ray diffraction

    International Nuclear Information System (INIS)

    Einstein, J.R.; Wei, C.H.

    1982-01-01

    We have been interested in structural elucidation by x-ray diffraction of compounds of biological interest. Understanding exactly how atoms are arranged in three-dimensional arrays as molecules can help explain the relationship between structure and functions. The species investigated may vary in size and shape; our recent studies included such diverse substances as antischistosomal drugs, a complex of cadmium with nucleic acid base, nitrate salts of adenine, and proteins

  2. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  3. Producing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.; Jung, R.G.; Applebaum, D.C.; Fairand, B.P.; Gallagher, W.J.

    1977-01-01

    A method of producing x-rays by directing radiant energy from a laser onto a target is described. Conversion efficiency of at least about 3 percent is obtained by providing the radiant energy in a low-power precursor pulse of approximately uniform effective intensity focused onto the surface of the target for about 1 to 30 nanoseconds so as to generate an expanding unconfined coronal plasma having less than normal solid density throughout and comprising a low-density (underdense) region wherein the plasma frequency is less than the laser radiation frequency and a higher-density (overdense) region wherein the plasma frequency is greater than the laser radiation frequency and, about 1 to 30 nanoseconds after the precursor pulse strikes the target, a higher-power main pulse focused onto the plasma for about 10 -3 to 30 nanoseconds and having such power density and total energy that the radiant energy is absorbed in the underdense region and conducted into the overdense region to heat it and thus to produce x-rays therefrom with the plasma remaining substantially below normal solid density and thus facilitating the substantial emission of x-rays in the form of spectral lines arising from nonequilibrium ionization states

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x- ... x-ray machine is a compact apparatus that can be taken to the patient in a hospital ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... shades of gray and air appears black. Until recently, x-ray images were maintained on large film ... assist you in finding the most comfortable position possible that still ensures x-ray image quality. top ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... can be taken to the patient in a hospital bed or the emergency room. The x-ray ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg (shin), ankle or foot. top of page ... the patient standing upright, as in cases of knee x-rays. A portable x-ray machine is ...

  12. X-ray detector array

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    The object of the invention (an ionization chamber X-ray detector array for use with high speed computerised tomographic imaging apparatus) is to reduce the time required to produce a tomographic image. The detector array described determines the distribution of X-ray intensities in one or more flat, coplanar X-ray beams. It comprises three flat anode sheets parallel to the X-ray beam, a plurality of rod-like cathodes between the anodes, a detector gas between the electrodes and a means for applying a potential between the electrodes. Each of the X-ray sources is collimated to give a narrow, planar section of X-ray photons. Sets of X-ray sources in the array are pulsed simultaneously to obtain X-ray transmission data for tomographic image reconstruction. (U.K.)

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... image on photographic film or a special detector. Different parts of the body absorb the x-rays ... process is repeated. Two or three images (from different angles) will typically be taken. An x-ray ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... up in shades of gray and air appears black. Until recently, x-ray images were maintained on ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissues around or in bones. top of page How should I prepare? Most bone x-rays require ... is placed beneath the patient. top of page How does the procedure work? X-rays are a ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and ...

  20. Soft X-ray Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Seely, John

    1999-05-20

    The contents of this report cover the following: (1) design of the soft x-ray telescope; (2) fabrication and characterization of the soft x-ray telescope; and (3) experimental implementation at the OMEGA laser facility.

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray technologist if there is any possibility that they are pregnant. Many imaging tests are not performed during pregnancy ...

  2. X-ray calibration facility for plasma diagnostics of the MegaJoule laser

    International Nuclear Information System (INIS)

    Hubert, S.; Prevot, V.

    2013-01-01

    The Laser MegaJoule (LMJ) located at CEA-CESTA will be equipped with x-ray plasma diagnostics using different kinds of x-ray components such as filters, mirrors, crystals, detectors and cameras. To guarantee LMJ measurements, detectors such as x-ray cameras need to be regularly calibrated. An x-ray laboratory is devoted to this task and performs absolute x-ray calibrations for similar x-ray cameras running on Laser Integration Line (LIL). This paper presents the x-ray calibration bench with its x-ray tube based High Energy x-ray Source (HEXS) and some calibration results. By mean of an ingenious transposition system under vacuum absolute x-ray calibration of x-ray cameras, like streak and stripline ones, can be carried out. Coupled to a new collimation system with micrometric accuracy on aperture sensitivity quantum efficiency measurements can be achieved with reduced uncertainties. (authors)

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... used for bone x-rays consists of an x-ray tube suspended over a table on which the patient ... a hospital bed or the emergency room. The x-ray tube is connected to a flexible arm that is ...

  4. X-ray Crystallography Facility

    Science.gov (United States)

    2000-01-01

    Edward Snell, a National Research Council research fellow at NASA's Marshall Space Flight Center (MSFC), prepares a protein crystal for analysis by x-ray crystallography as part of NASA's structural biology program. The small, individual crystals are bombarded with x-rays to produce diffraction patterns, a map of the intensity of the x-rays as they reflect through the crystal.

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  6. Tunable X-ray source

    Science.gov (United States)

    Boyce, James R [Williamsburg, VA

    2011-02-08

    A method for the production of X-ray bunches tunable in both time and energy level by generating multiple photon, X-ray, beams through the use of Thomson scattering. The method of the present invention simultaneously produces two X-ray pulses that are tunable in energy and/or time.

  7. X-Ray Exam: Ankle

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What It Is Why ... You Have Questions Print What It Is An ankle X-ray is a safe and painless test ...

  8. Programmers for diagnostic x-ray apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Novel apparatus is described for providing a pre-programmed selection of various parameters in X-ray radiography. The equipment consists of push-buttons which prompt the radiographer to make decisions such as thickness of patient, part of the anatomy to be X-rayed etc. From these data the apparatus selects the appropriate parameters such as H.T. voltage, current, product of current and irradiation time etc. The values of these parameters are displayed to the radiographer and facilities are provided to override the programmed parameters at the radiographer's discretion. (U.K.)

  9. Dose levels in conventional X-rays

    International Nuclear Information System (INIS)

    Guerra M, J. A.; Gonzalez G, J. A.; Pinedo S, A.; Salas L, M. A.; Vega C, H. R.; Rivera M, T.; Azorin N, J.

    2009-10-01

    There were a series of measures in the General Hospital of Fresnillo in the X-ray Department in the areas of X-1 and X-2-ray rooms and in the neonatal intensive care unit 2, was determined the dose surface entry in eyes, thyroid and gonads for patients undergoing to X-ray study of chest Tele by thermoluminescent dosimetry. Five dosemeters were used in each one of the scans; so find the following dose ranges 20 + - 23 mGy to 350 + - 41 mGy. With the results obtained we can conclude that the procedures used and the equipment calibration is adequate. (Author)

  10. Obstetric X-rays

    International Nuclear Information System (INIS)

    Mwachi, M.K.

    2006-01-01

    Radiography of the pelvis should never be taken to diagnose early pregnancy, because of potential hazards of radiation damage to the growing foetus. the only indication occurs in the last week of pregnancy (37 weeks). Obstetric X-ray will help you answer like confirmation of malposition,multiple pregnancies; fetal abnormalities e.g. hydrocephalus, foetal disposition. The choice of radiographic projection will help give foetal presentation, disposition as well as foetal maturity. The search pattern helps you determine maternal and spine deformity, foetal spine and head , foetal presentation and any other anomalies

  11. Miniature X-Ray Tubes

    Science.gov (United States)

    Bearman, Gregory H.

    1995-01-01

    Miniature x-ray tubes proposed for use in portable instruments used to analyze minerals. Electrons from field emitter (instead of thermionic emitter) accelerated to target to generate x-rays. Fabricated from silicon wafers, micromachined field emitters (MFEs) not subject to breakage or restrictions on lifetimes, and tolerate vacuums that filaments cannot. Miniature x-ray tubes very robust, immune to shock and vibration, and permanently sealed with getter for continued pumping. Combined with solid-state x-ray detectors for analysis of x-ray fluorescence.

  12. X-ray spectral meter of high voltages for X-ray apparatuses

    International Nuclear Information System (INIS)

    Zubkov, I.P.; Larchikov, Yu.V.

    1993-01-01

    Design of the X-ray spectral meter of high voltages (XRSMHV) for medical X-ray apparatuses permitting to conduct the voltage measurements without connection to current circuits. The XRSMHV consists of two main units: the detector unit based on semiconductor detector and the LP4900B multichannel analyzer (Afora, Finland). The XRSMYV was tested using the pilot plant based on RUM-20 X-ray diagnostic apparatus with high-voltage regulator. It was shown that the developed XRSMHV could be certify in the range of high constant voltages form 40 up to 120 kV with the basic relative error limits ±0.15%. The XRSMHV is used at present as the reference means for calibration of high-voltage medical X-ray equipment

  13. Properties and potential of an X-ray system with polycapillary focussing

    International Nuclear Information System (INIS)

    Trojek, Tomas

    2010-01-01

    The article deals with the testing and applications of an X-ray tube equipped with polycapillary optics. The focus of the paper is on determining the beam profile, focal spot distance, X-ray spectra and angular distributions of the emitted X-rays. The ambient dose equivalent in the surroundings of the X-ray tube was also measured. Owing to the very narrow X-ray beam in the focal spot, the X-ray tube with the polycapillary optics may find use in structural and chemical analysis of materials as well as in local irradiation of samples. Application of the device in X-ray fluorescence microanalysis is described

  14. Soft x-ray lasers

    International Nuclear Information System (INIS)

    Matthews, D.L.; Rosen, M.D.

    1988-01-01

    One of the elusive dreams of laser physicists has been the development of an x-ray laser. After 25 years of waiting, the x-ray laser has at last entered the scientific scene, although those now in operation are still laboratory prototypes. They produce soft x rays down to about five nanometers. X-ray lasers retain the usual characteristics of their optical counterparts: a very tight beam, spatial and temporal coherence, and extreme brightness. Present x-ray lasers are nearly 100 times brighter that the next most powerful x-ray source in the world: the electron synchrotron. Although Lawrence Livermore National Laboratory (LLNL) is widely known for its hard-x-ray laser program which has potential applications in the Strategic Defense Initiative, the soft x-ray lasers have no direct military applications. These lasers, and the scientific tools that result from their development, may one day have a place in the design and diagnosis of both laser fusion and hard x-ray lasers. The soft x-ray lasers now in operation at the LLNL have shown great promise but are still in the primitive state. Once x-ray lasers become reliable, efficient, and economical, they will have several important applications. Chief among them might be the creation of holograms of microscopic biological structures too small to be investigated with visible light. 5 figs

  15. Recent nondestructive evaluation systems using x rays

    International Nuclear Information System (INIS)

    Fujii, Masashi; Matsuura, Shigeo.

    1985-01-01

    With popularization of image memory and image processing systems, computer-aided testing (CAT) technology is finding way into the field of X-ray nondestructive inspection. Conventional methods using X-ray film are being replaced by computed radiographs using imaging plates or X-ray television, and the conventional two-dimensional projection image technology is being replaced by the CT scanner technology that offers three-dimensional images. In the field of electronic devices and parts such as semiconductors and printed circuit boards, ''TOSMICRON'' series featuring ultrahigh magnification power and outstanding operability have been developed to cope with the trend of increasing in device size and in precision requirements. These systems can be connected on line with a high-speed image processing equipment having image processing hardware to achieve unattended defect detection, size determination and classification. (author)

  16. X-ray tube

    International Nuclear Information System (INIS)

    Mayo, B.J.

    1980-01-01

    An x-ray tube in which the x-ray origin is scanned on a circle around the patient, comprises a ring-shaped anode, an electron beam travelling along a circular path being deflected onto the anode at the desired positions. The electron beam path may be in a plane parallel to the anode and perhaps at the same radius. It may be in the same plane as a transmission target/anode and at a greater radius. The anode should extend over at least 180 0 although it may extend to 360 0 . Electrostatic means may be provided to constrain the beam to the circular path and further electrostatic means deflect it to the anode of the beam and ensure it is focused at the point of incidence. Collimators provide a planar fan-shaped beam and the anode may be shaped to attenuate side lobes of the radiation. Electrode collects electrons not deflected. The focal regions may be adjacent or otherwise. Coils may provide periodic focusing to overcome space charge dispersion and dynamic adjustment of the focusing before deflection ensures focusing at target incidence. Focusing may be absent near the deflection region, and current in the coil section near the focal region should be zero. (author)

  17. Do we need X-rays?

    International Nuclear Information System (INIS)

    Sadat, Theo

    2004-01-01

    Do we need X-rays? The answer depends on the cost for 25 kGy sterilization, and the cost for 10 kGy decontamination, compared with the costs of other technologies. In the past, the cost of X-ray was compared with that of Cobalt 60, because treatment by pallet was virtually obsessional. It was considered easier to treat in a Contract Service Center even though several Contract Service Centers equipped with 10 MeV high-power accelerators are in operation, and are profitable. Currently small and reliable accelerators are available, which can be inserted into a production line, i.e. instead of treating a product in its shipment carton or on a pallet, the product can be treated as a unit on the production line. In this case there is no need for extra transport, or intermediate storage facilities, and the product is 'just in time'. So we should compare the cost of treatment, taking all these parameters into account (transport, storage, time lapse, etc.) to find out if X-ray treatment could be competitive. The few studies carried out in the past compared X-ray with Cobalt 60, and the economic result was always in favour of Cobalt due to the poor conversion output. This is still valid today, even if we consider very high-power electron beam accelerators. The performance and cost of e-beam in-line, gamma ray and X-ray will be compared

  18. Development of a dosimetric system for dental X-ray equipment quality control; Desenvolvimento de um sistema dosimetrico para controle de qualidade de equipamentos de raios-X odontologicos

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  19. X-ray radiography of abdominal emergencies in clinical diagnosis

    International Nuclear Information System (INIS)

    Bencur, J.M.; Svoboda, M.

    1987-01-01

    The book explains in detail the procedure in X-ray examination and how to get the maximum of diagnostic information out of it. Part one is devoted to the organization, technology and methodology of X-ray examinations, the equipment of X-ray units and to radiation protection. Part two presents the anatomy of the abdomen and of the thorax, and the pathological manifestations of emergencies in the X-ray picture. Part three presents an analysis of the individual types of diseases and injuries illustrated with many pictures. (M.D.). 96 figs., 7 tabs., 400 refs

  20. Influence of the input voltage electric configurations and fall of intrinsic voltage of the equipment of X rays odontological periapical in the KVP

    Energy Technology Data Exchange (ETDEWEB)

    Laranjeira, A.S.; Almeida, C.D. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mails: adilson@ird.gov.br; claudio@ird.gov.br

    2007-07-01

    The concessionaire of electric energy does not supply a input voltage stable (in the city of Rio De Janeiro the LIGHT only guarantees the single-phase supply and a band of 116 the 132 VCA). As the devices of rays X odontological periapical conventional do not possess voltage regulator, kVp of x-ray tube are influenced. These devices are found in two basic electric configurations of nominal input voltage, 110 and 127 VAC. As the input voltage (Vin) as seen it is not fixed, depending on the used configuration, a different nominal kVp will be generated one (above or below). In this process it also participates the fall of intrinsic voltage in the entrance of the headstock (after timer). The tests had been made in a device of rays X with electric configuration of 110 VAC, 60 kVp and 10 mA, simulating the conditions of variation of the electric net in laboratory. It was used, a digital multimeter, a not invasive measurer of kVp and a Variac. The values of used Vin for the tests had been, 110, 118, 127 VAC. The corresponding values for the fall of intrinsic tension and kVp had been respectively, of 99 (- 10% of the Vin), 103 (- 13% of the Vin) and 111 VAC (- 12% of the Vin), and for kVp 60, 63 and 69 kVp. It was concluded that the Vin varied kVp, making with that it was above or below its nominal value, depending on the used electric configuration, and that the fall of intrinsic tension of the tested device did not affect kVp. (author)

  1. Influence of the input voltage electric configurations and fall of intrinsic voltage of the equipment of X rays odontological periapical in the KVP

    International Nuclear Information System (INIS)

    Laranjeira, A.S.; Almeida, C.D.

    2007-01-01

    The concessionaire of electric energy does not supply a input voltage stable (in the city of Rio De Janeiro the LIGHT only guarantees the single-phase supply and a band of 116 the 132 VCA). As the devices of rays X odontological periapical conventional do not possess voltage regulator, kVp of x-ray tube are influenced. These devices are found in two basic electric configurations of nominal input voltage, 110 and 127 VAC. As the input voltage (Vin) as seen it is not fixed, depending on the used configuration, a different nominal kVp will be generated one (above or below). In this process it also participates the fall of intrinsic voltage in the entrance of the headstock (after timer). The tests had been made in a device of rays X with electric configuration of 110 VAC, 60 kVp and 10 mA, simulating the conditions of variation of the electric net in laboratory. It was used, a digital multimeter, a not invasive measurer of kVp and a Variac. The values of used Vin for the tests had been, 110, 118, 127 VAC. The corresponding values for the fall of intrinsic tension and kVp had been respectively, of 99 (- 10% of the Vin), 103 (- 13% of the Vin) and 111 VAC (- 12% of the Vin), and for kVp 60, 63 and 69 kVp. It was concluded that the Vin varied kVp, making with that it was above or below its nominal value, depending on the used electric configuration, and that the fall of intrinsic tension of the tested device did not affect kVp. (author)

  2. X-ray face mask and chest shield device

    International Nuclear Information System (INIS)

    Moti, S.

    1981-01-01

    A protective face mask is designed to shield an x-ray technician or machine operator primarily from random secondary or scatter x-rays deflected towards his face, head and neck by the table, walls, equipment and other reflecting elements in an x-ray room or chamber. The face mask and chest shield device can be mounted on a patient's shoulders in reverse attitude to protect the back of a patient's head and neck from the x-ray beam. The face mask is relatively or substantially transparent and contains lead in combination with a plastic ionomer or comonomer, which to a degree absorbs or resists penetration of the random deflected secondary or scatter x-rays or the x-ray beam through the mask. The face mask is removably attachable to the chest shield for easy application of the device to and support upon the shoulders of the technician or the patient. (author)

  3. Import and market development for dental x-ray equipment in Vietnam : case: Meditronic Centre – Viettronic DongDa Joint Stock Company

    OpenAIRE

    Nguyen, Minh Hanh

    2010-01-01

    In recent years, the demand for medical and dental equipment in Vietnam has been dramatically increased. Due to the dire need of modernizing the healthcare infrastructure in Vietnam, opportunities have arisen for local importers to penetrate overseas healthcare-related products into this market. In this study, an operational import plan of dental equipment appears as a proper suggestion for market players. The thesis is carried out based on the real case of Meditronic centre, Viettronic D...

  4. X-ray table

    International Nuclear Information System (INIS)

    Craig, J.R.; Otto, G.W.

    1980-01-01

    An X-ray radiographic or fluoroscopic table is described which includes a film holder with a frame attached to a cable running over end pulleys for positioning the holder longitudinally as desired under the table top. The holder has a front opening to receive a cassette-supporting tray which can be slid out on tracks to change the cassette. A reed switch on the frame is opened by a permanent magnet on the tray only when the tray is half-way out. When the switch is closed, an electromagnet locks the pulley and the holder in place. The holder is thus automatically locked in place not only during exposure (tray in) but when the tray is out for changing the cassette. To re-position the holder, the operator pulls the tray half-out and, using the tray itself, pushes the holder along the table, the holder being counterbalanced by a weight. (author)

  5. X-ray instrumentation in astronomy

    International Nuclear Information System (INIS)

    Cuhlane, J.L.

    1985-01-01

    This book presents the proceedings of a conference devoted to x-ray instrumentation in astronomy. Special sections are: AXAF X-Ray Optical Systems; Specialized X-Ray Systems; X-Ray Optical Systems I; X-Ray Optical Systems II; Gas Filled X-Ray Detectors II; The NASA Advanced X-Ray Astrophysics Facility; X-Ray and EUV Spectrometers; Microchannel Plates; and Solid State Detectors

  6. X-Ray Lasers 2016

    CERN Document Server

    Bulanov, Sergei; Daido, Hiroyuki; Kato, Yoshiaki

    2018-01-01

    These proceedings comprise a selection of invited and contributed papers presented at the 15th International Conference on X-Ray Lasers (ICXRL 2016), held at the Nara Kasugano International Forum, Japan, from May 22 to 27, 2016. This conference was part of an ongoing series dedicated to recent developments in the science and technology of x-ray lasers and other coherent x-ray sources with additional focus on supporting technologies, instrumentation and applications.   The book showcases recent advances in the generation of intense, coherent x-rays, the development of practical devices and their applications across a wide variety of fields. It also discusses emerging topics such as plasma-based x-ray lasers, 4th generation accelerator-based sources and higher harmonic generations, as well as other x-ray generation schemes.

  7. X-raying with low dose irradiation

    International Nuclear Information System (INIS)

    Malevich, E.E.; Kisel, E.M.; Shpita, I.D.; Lazovsky, A.S.

    2001-01-01

    with higher frequency of a pulsation the share of unproductive radiation is higher. At x-raying controlled by the grid pulses are generated by the x-ray tube with the grid control. The grid, located between the cathode and the anode, passes the electron cloud without the expenses of time for dispersal and attenuation. It gives sharply outlined, rectangular x-ray pulses with homogeneous quality of radiation. Function GC F -x-raying controlled by the grid - enables to receive precisely outlined contours of moving objects: a heart, a gullet, - and also to carry out examination of the children without information loss during simultaneous dose decrease. Besides the image remains precise even during the movement of the electron-optical converter. Owing to radiation parameters adjustment during the examination the effect of the lighted image is eliminated. X-raying devices Easy Diagnose and Diagnose-76 'Philips' are equipped with the system of digital x-ray image processing besides they are completed with the x-ray tube with Grid Controlled Fluoroscopy that allows to carry out pulse x-raying with number of pulses 2, 3, 6 and 12 per a second. So, with 12 pulses per second the irradiation dose in comparison with continuous radiation decreases on 40%. The examinations of a chest, gullet, stomach and thick gut were carried out at the frequency of 12 and 6 pulses per second. In the hospital of the Ministry of Internal Affairs where device Easy Diagnose is established, at examinations of a gastro enteric path (stomach x-raying, irrigoscopy) usually pulse x-raying is used with frequency 12 pulses per second. It allows significantly reduce the beam load on a patient. The calculation of beam loads on a patient was carried out on the basis of exposition dose level at the beam input in the body of a patient (entrance dose). The way is applied for especially exact calculations, as definitions of effective doses on separate organs and all body are difficult. The irradiation dose is in

  8. Topological X-Rays Revisited

    Science.gov (United States)

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  9. X-ray filtration apparatus

    International Nuclear Information System (INIS)

    Thompson, G.

    1992-01-01

    This invention relates to an X-ray shielding support device. In spite of considerable development in X-ray taking techniques, a need still exists for effective shielding, inter alia, to compensate for variations in the thickness, density and the absorption properties of the object being studied. By appropriate shielding, the X-ray image produced is of sufficient detail, contrast and intensity over its entire area to constitute a useful diagnostic aid. It is also desirable to subject the patient to the smallest possible X-ray dosage. 4 figs

  10. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  11. X-ray emission spectroscopy. X-ray fluorescence

    International Nuclear Information System (INIS)

    Despujols, J.

    1992-01-01

    Principles of X-ray emission spectrometry are first recalled, then wave-length dispersive and energy dispersive X-ray fluorescence spectrometer are described. They are essentially designed for qualitative and quantitative analysis of elements (Z>10). Sample preparation, calibration, corrections, interferences, accuracy are reviewed. Examples of use in different industries are given. (71 refs.)

  12. Comparing of the yield curve of the pediatric X-ray equipment using thermoluminescent dosimeters and cylindrical ionization chamber; Comparacao da curva de rendimento de um aparelho de raios X pediatrico utilizando dosimetros termoluminescentes e camara de ionizacao cilindrica

    Energy Technology Data Exchange (ETDEWEB)

    Filipov, Danielle, E-mail: dfilipov@utfpr.edu.br [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Schelin, Hugo R., E-mail: ledesmaiorgealberto@gmail.com [Instituto de Pesquisa Pele Pequeno Principe, Curitiba, PR (Brazil); Tilly Junior, Joao G., E-mail: joao.tilly@derax.com.br [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Hospital de Clinicas

    2014-07-01

    The determination of the yield curve of a radiographic equipment should be realized once a year, or when the unit be serviced. Besides being a requirement of ANVISA, through this test is possible to determine the incident air kerma (at a given point in the center of the beam) - INAK. Based on these concepts, the main objective of this work is the comparison of yield curves of the pediatric X-ray apparatus using two different detectors: one cylindrical ionization chamber and thermoluminescent dosimeters type LiF: Mg, Cu, P, as per protocol RLA / 9/057 IAEA. Then the equation of the yield curve (generated by each detector) was used to determine the INAK of 10 pediatric examinations, performed on this equipment. After the process of calibration of both detectors, they were placed side by side at a focus of the tube equipment for determining the performance of the same curve. Finally, using the curves generated by two detectors, INAK values of the 10 tests were calculated (from the kVp values, and mAs focus-patient of each exams), generating difference values at most 5%. As a conclusion, it can be said that the TLD lithium fluoride doped with Mg, Cu and P and the cylindrical ionization chambers may be used satisfactorily to determine the yield curve, whether as quality control or dosimetry.

  13. DCARR: a spectrograph for measuring low-energy x rays

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    DCARR, the Differential Critical Angle Reflection Refraction detector system, is described. This detector was designed to measure low-energy x rays, 500 to 5000 eV, with a high degree of resolution, 250 eV. DCARR was developed because these low-energy measurements are of interest in the diagnostics of x-radiation in nuclear tests and available equipment could not make measurements at this low an energy in field tests. DCARR is a versatile piece of equipment that can also be used as a laboratory tool, such as in measuring the low-energy x rays emitted by lasers and various x-ray machines

  14. Highly Sensitive and Selective Uranium Detection in Natural Water Systems Using a Luminescent Mesoporous Metal-Organic Framework Equipped with Abundant Lewis Basic Sites: A Combined Batch, X-ray Absorption Spectroscopy, and First Principles Simulation Investigation.

    Science.gov (United States)

    Liu, Wei; Dai, Xing; Bai, Zhuanling; Wang, Yanlong; Yang, Zaixing; Zhang, Linjuan; Xu, Lin; Chen, Lanhua; Li, Yuxiang; Gui, Daxiang; Diwu, Juan; Wang, Jianqiang; Zhou, Ruhong; Chai, Zhifang; Wang, Shuao

    2017-04-04

    Uranium is not only a strategic resource for the nuclear industry but also a global contaminant with high toxicity. Although several strategies have been established for detecting uranyl ions in water, searching for new uranium sensor material with great sensitivity, selectivity, and stability remains a challenge. We introduce here a hydrolytically stable mesoporous terbium(III)-based MOF material compound 1, whose channels are as large as 27 Å × 23 Å and are equipped with abundant exposed Lewis basic sites, the luminescence intensity of which can be efficiently and selectively quenched by uranyl ions. The detection limit in deionized water reaches 0.9 μg/L, far below the maximum contamination standard of 30 μg/L in drinking water defined by the United States Environmental Protection Agency, making compound 1 currently the only MOF material that can achieve this goal. More importantly, this material exhibits great capability in detecting uranyl ions in natural water systems such as lake water and seawater with pH being adjusted to 4, where huge excesses of competing ions are present. The uranyl detection limits in Dushu Lake water and in seawater were calculated to be 14.0 and 3.5 μg/L, respectively. This great detection capability originates from the selective binding of uranyl ions onto the Lewis basic sites of the MOF material, as demonstrated by synchrotron radiation extended X-ray adsorption fine structure, X-ray adsorption near edge structure, and first principles calculations, further leading to an effective energy transfer between the uranyl ions and the MOF skeleton.

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images are easily accessible and are frequently compared to current x-ray images for diagnosis and ... the x-ray film holder or digital recording plate under the table in the area ...

  16. Chandra's X-ray Vision

    Indian Academy of Sciences (India)

    1999-07-23

    Jul 23, 1999 ... GENERAL I ARTICLE. Chandra's X-ray Vision. K P Singh. Chandra X-ray Observatory (CXO) is a scientific satellite (moon/ chandra), named after the Indian-born Nobel laureate. Subrahmanyan Chandrasekhar - one of the foremost astro- physicists of the twentieth century and popularly known as. Chandra.

  17. Traditional x-ray imaging

    International Nuclear Information System (INIS)

    Hay, G.A.

    1982-01-01

    Methods of imaging x-rays, with particular reference to medicine, are reviewed. The history and nature of x-rays, their production and spectra, contrast, shapes and fine structure, image transducers, including fluorescent screens, radiography, fluoroscopy, and image intensifiers, image detection, perception and enhancement and clinical applications are considered. (U.K.)

  18. X-ray based extensometry

    Science.gov (United States)

    Jordan, E. H.; Pease, D. M.

    1988-01-01

    A totally new method of extensometry using an X-ray beam was proposed. The intent of the method is to provide a non-contacting technique that is immune to problems associated with density variations in gaseous environments that plague optical methods. X-rays are virtually unrefractable even by solids. The new method utilizes X-ray induced X-ray fluorescence or X-ray induced optical fluorescence of targets that have melting temperatures of over 3000 F. Many different variations of the basic approaches are possible. In the year completed, preliminary experiments were completed which strongly suggest that the method is feasible. The X-ray induced optical fluorescence method appears to be limited to temperatures below roughly 1600 F because of the overwhelming thermal optical radiation. The X-ray induced X-ray fluorescence scheme appears feasible up to very high temperatures. In this system there will be an unknown tradeoff between frequency response, cost, and accuracy. The exact tradeoff can only be estimated. It appears that for thermomechanical tests with cycle times on the order of minutes a very reasonable system may be feasible. The intended applications involve very high temperatures in both materials testing and monitoring component testing. Gas turbine engines, rocket engines, and hypersonic vehicles (NASP) all involve measurement needs that could partially be met by the proposed technology.

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  1. X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Attekum, P.M.T.M. van.

    1979-01-01

    The methods and results of X-ray photoelectron spectroscopy in the study of plasmons, alloys and gold compounds are discussed. After a comprehensive introduction, seven papers by the author, previously published elsewhere, are reprinted and these cover a wide range of the uses of X-ray photoelectron spectroscopy. (W.D.L.)

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very ... they provide little information about muscles, tendons or joints. An MRI may ...

  3. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic radiography is described in detail. It comprises a tubular target carrier supporting at its distal end a target with an inclined forward face. Image definition is improved by positioning in the path of the X-rays a window of X-ray transmitting ceramic material, e.g. 90% oxide of Be, or Al, 7% Si0 2 . The target carrier forms a probe which can be positioned in the patient's mouth. X-rays are directed forwardly and laterally of the target to an X-ray film positioned externally. The probe is provided with a detachable sleeve having V-form arms of X-ray opaque material which serve to depress the tongue out of the radiation path and also shield the roof of the mouth and other regions of the head from the X-ray pattern. A cylindrical lead shield defines the X-ray beam angle. (author)

  4. Monitoring Instrument for X-Ray Box

    CERN Document Server

    Cifuentes Ospina, Alberto; Kuehn, Susanne; Schaepe, Steffen; CERN. Geneva. EP Department

    2017-01-01

    A humidity and temperature readout instrument has been designed and implemented in order to monitor the X-Ray Box used for testing the silicon detectors prototypes of the ITk. The sensors are connected to an Arduino Mega board equipped with 16 analog inputs and a serial port to a computer. A user-friendly software has been also designed in order to give an easy access to all measurements.

  5. An X-ray exposure calculator

    International Nuclear Information System (INIS)

    Horsington, G.

    1983-01-01

    An algorithm and an 'Applesoft' program are presented for calculating the X-ray exposure factors for an Oldelft Radiotherapy Simulator. The program runs on a 48K Apple II Europlus computer. Also described are the variables which would need to be altered to make the program suitable for other equipment, and describes the Applesoft commands that may need to be translated into another Basic dialect in order to run it on a different computer. (author)

  6. X-ray imaging system

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    A novel, high-speed apparatus for use in X-ray computerised tomography is described in detail. It consists of a semi-circular array of X-ray sources, collimators and an ion chamber array for detection of the X-rays. The X-ray sources may be pulsed in salvos such that the corresponding detectors in the array are only illuminated by one source. The use of computer controlled salvos speeds up the image processing by at least a factor of two. The ion chamber array is designed to have a constant detection efficiency for varying angles of X-ray incidence. A detailed description of the detector construction and suggested gaseous fillings are given. It is claimed that the present tomographic system allows fast and accurate imaging of internal body organs and is insensitive to the blurring effects which motion of these organs tends to produce. (UK)

  7. X-Ray Tomographic Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bonnie Schmittberger

    2010-08-25

    Tomographic scans have revolutionized imaging techniques used in medical and biological research by resolving individual sample slices instead of several superimposed images that are obtained from regular x-ray scans. X-Ray fluorescence computed tomography, a more specific tomography technique, bombards the sample with synchrotron x-rays and detects the fluorescent photons emitted from the sample. However, since x-rays are attenuated as they pass through the sample, tomographic scans often produce images with erroneous low densities in areas where the x-rays have already passed through most of the sample. To correct for this and correctly reconstruct the data in order to obtain the most accurate images, a program employing iterative methods based on the inverse Radon transform was written. Applying this reconstruction method to a tomographic image recovered some of the lost densities, providing a more accurate image from which element concentrations and internal structure can be determined.

  8. Laboratory of computerized tomography and X-ray of Centro Federal de Educacao Tecnologica (CEFET) from Parana State, Brazil

    International Nuclear Information System (INIS)

    Schelin, Hugo R.; Paschuk, Sergei A.; Jakubiak, Rosangela J.; David, Denise E.H.; Gomes, Cintia L.; Soboll, Daniel S.; Ruehle, Gustavo; Carvalho, Arnolfo

    1996-01-01

    The development of X-ray laboratory at CEFET-PR (Brazil) is considered. The advancement and hospital practice application of an Image Quality Program for X-ray and tomography scanning is studied. A project regarding to the modernization of installed X-ray equipment, particularly X-ray detector, software and hardware is reported

  9. Evaluation of the conditions of operation of X-ray equipment as regards the coincidence between light field, radiation field and the central ray alignment in radiology services of the Recife, Brazil

    International Nuclear Information System (INIS)

    Oliveira, Claudia F.M.; Silva, Iran J.O.; Lopes Filho, Ferdinand J.; Morais, Carolinne S.; Junior, Claudio L.R.

    2014-01-01

    This paper aims at considering the need for constant evaluation of diagnostic radiology equipment and the fact that this issue be part of the radiology technologist's tasks, develop skills in radiology technologist through applying quality control tests, as regards the assessment of coincidence between the light field and the radiation field and the alignment of the radiation beam of medical X-ray equipment in radiology services in the city of Recife. For the tests, the procedures by national protocols of Quality Control Tests were adopted - QCT and the Medical Radiodiagnosis Manual. The instruments used to check the alignment of the central ray was an acrylic cylinder with steel balls of 0.8 mm diameter located in the upper and lower base separated by a distance of 15 cm, a chassis loaded with film, tape and level bubble. The results show that the tested devices are in good condition for diagnostic radiology, with regard to both the radiation field to be exposed as well as the image quality for a more accurate diagnosis, which guarantees the individual radiological protection

  10. X-ray measurements on wood - spectra measurements

    DEFF Research Database (Denmark)

    Jensen, Signe Kamp; Thygesen, Lisbeth Garbrecht; Gerward, Leif

    The report concerns simultaneous non-destructive measurements of water content and density of wood. Theoretically, this should be possible using a x-ray equipment newly build at BKM, and this work is an attempt to use the equipment for assessing water content and density of wood samples under...... laboratory conditions. A number of wood samples with different densities are placed at different relative humidities from 0.5 to 97 %RH. When equilibrium is obtained the samples are measured with the x-ray equipment such that 10 points are measured in the sample followed by measurements outside the sample...... (free-scanning). In this way 100 points are measured for each wood sample. This produces information about moisture content and density of the samples as water and wood attenuations of the x-rays are different for the different energy levels contained in the x-rays. The "real" density and moisture...

  11. use of x-ray fluorescence spectrometry to determine trace elements ...

    African Journals Online (AJOL)

    NIJOTECH

    here, an X-ray spectrometer was constructed and used to detect the presence of trace elements in graphite matrix by their K fluorescence X-ray lines. Equipment. The spectrometer consisted of an X-ray tube. (as primary source), a sample holder and a turn-table carrying the analyzer crystal and the detector, all mounted on ...

  12. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  13. Commissioning of a proton gantry equipped with dual x-ray imagers and a robotic patient positioner, and evaluation of the accuracy of single-beam image registration for this system

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ning; Ghebremedhin, Abiel; Patyal, Baldev, E-mail: bpatyal@llu.eduss [Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California 92354 (United States)

    2015-06-15

    Purpose: To check the accuracy of a gantry equipped with dual x-ray imagers and a robotic patient positioner for proton radiotherapy, and to evaluate the accuracy and feasibility of single-beam registration using the robotic positioner. Methods: One of the proton treatment rooms at their institution was upgraded to include a robotic patient positioner (couch) with 6 degrees of freedom and dual orthogonal kilovoltage x-ray imaging panels. The wander of the proton beam central axis, the wander of the beamline, and the orthogonal image panel crosswires from the gantry isocenter were measured for different gantry angles. The couch movement accuracy and couch wander from the gantry isocenter were measured for couch loadings of 50–300 lb with couch rotations from 0° to ±90°. The combined accuracy of the gantry, couch, and imagers was checked using a custom-made 30 × 30 × 30 cm{sup 3} Styrofoam phantom with beekleys embedded in it. A treatment in this room can be set up and registered at a setup field location, then moved precisely to any other treatment location without requiring additional image registration. The accuracy of the single-beam registration strategy was checked for treatments containing multiple beams with different combinations of gantry angles, couch yaws, and beam locations. Results: The proton beam central axis wander from the gantry isocenter was within 0.5 mm with gantry rotations in both clockwise (CW) and counterclockwise (CCW) directions. The maximum wander of the beamline and orthogonal imager crosswire centers from the gantry isocenter were within 0.5 and 0.8 mm, respectively, with the gantry rotations in CW and CCW directions. Vertical and horizontal couch wanders from the gantry isocenter were within 0.4 and 1.3 mm, respectively, for couch yaw from 0° to ±90°. For a treatment with multiple beams with different gantry angles, couch yaws, and beam locations, the measured displacements of treatment beam locations from the one based on

  14. X-ray diffraction apparatus

    International Nuclear Information System (INIS)

    Padini, F.R.

    1978-01-01

    The invention provides an x-ray diffraction apparatus permitting the rotation of the divergence sit in conjunction with the rotation of the x-ray irradiated specimen, whereby the dimensions of the x-ray irradiated portion of the specimen remain substantially constant during the rotation of the specimen. In a preferred embodiment, the divergence slit is connected to a structural element linked with a second structural element connected to the specimen such that the divergence slit rotates at a lower angular speed than the specimen

  15. X-ray film calibration

    International Nuclear Information System (INIS)

    Stone, G.F.; Dittmore, C.H.; Henke, B.L.

    1986-01-01

    This paper discusses the use of silver halide x-ray films for imaging and spectroscopy which is limited by the range of intensities that can be recorded and densitometered. Using the manufacturers processing techniques can result in 10 2-3 range in intensity recorded over 0-5 density range. By modifying the chemistry and processing times, ranges of 10 5-6 can be recorded in the same density range. The authors report on x-ray film calibration work and dynamic range improvements. Changes to the processing chemistry and the resulting changes in dynamic range and x-ray sensitivity are discussed

  16. Upsurge of X-ray astronomy 230-

    International Nuclear Information System (INIS)

    Hudec, D.R.

    1978-01-01

    Instruments are described used for X-ray astronomy, namely X-ray detectors and X-ray telescopes. Unlike telescopes, the detectors do not comprise X-ray optics. A survey is given of the results obtained in solar and stellar X-ray astronomy and hypotheses are submitted on the origin of X radiation in the interstellar space. (J.B.)

  17. Results of the technical evaluation of dentistry X-ray equipment of a faculty of Dentistry of Rio Grande do Sul State, based on Regulation 453 of Health Ministry and IRD/CNEN-BR recommendations; Resultados das analises tecnicas realizadas nos equipamentos de raios-X odontologicos de uma faculdade de Odontologia do Rio Grande do Sul, segundo Portaria 453 do Ministerio da Saude e recomendacoes do IRD/CNEN

    Energy Technology Data Exchange (ETDEWEB)

    Staevie, G.L.G.; Jahn, T.R.; Barbieri, D.X.; Mas, C.R Dal; Sbaraini, P.; Saba, J.C.P. [Pontificia Univ. Catolica do Rio Grande do Sul, Porto Alegre, RS (Brazil). Inst. de Pesquisas Cientificas e Tecnologicas. Div. de Engenharia Biomedica]. E-mail: staevie@pucrs.br

    2001-07-01

    This paper describes the technical evaluation of odontology X-ray equipment installed in a local school of odontology with regard to the fulfillment of requirements of Regulation No. 453, issued by Brazilian Ministry of Health and the recommendations of the Institute of Radiation Protection and Dosimetry, IRD/CNEN. Fifteen intra-oral odontology X-ray equipment were evaluated and their conformities and non-conformities were identified, followed by recommendations to be adopted by the school. (author)

  18. Dosimetry of x-ray beams: The measure of the problem

    International Nuclear Information System (INIS)

    de Castro, T.M.

    1986-08-01

    This document contains the text of an oral presentation on dosimetry of analytical x-ray equipment presented at the Denver X-Ray Conference. Included are discussions of sources of background radiation, exposure limits from occupational sources, and the relationship of these sources to the high dose source of x-rays found in analytical machines. The mathematical basis of x-ray dosimetry is reviewed in preparation for more detailed notes on personnel dosimetry and the selection of the most appropriate dosimeter for a specific application. The presentation concludes with a discussion common to previous x-ray equipment accidents. 2 refs

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ... and places the x-ray film holder or digital recording plate under the table in the area ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... bone in the body, including the hand, wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg ( ... x-ray tube is connected to a flexible arm that is extended over the patient while an ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to X-ray (Radiography) - Bone Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to produce pictures of any bone in the body. It is commonly used to diagnose fractured bones ... x-rays involves exposing a part of the body to a small dose of ionizing radiation to ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement and fracture reductions. look for injury, ... CT Exams Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety How to Read Your Radiology ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... will analyze the images and send a signed report to your primary care or referring physician , who ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  7. X-Ray Assembler Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — Federal regulations require that an assembler who installs one or more certified components of a diagnostic x-ray system submit a report of assembly. This database...

  8. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic dental radiography is described in detail. It comprises an electron gun having an elongated tubular target carrier extending into the patient's mouth. The carrier supports an inclined target for direction of an X-ray pattern towards a film positioned externally of the patient's mouth. Image definition is improved by a focusing anode which focuses the electron beam into a sharp spot (0.05 to 0.10 mm diameter) on the target. The potential on the focusing anode is adjustable to vary the size of the spot. An X-ray transmitting ceramic (oxides of Be, Al and Si) window is positioned adjacent to the front face of the target. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ... or your insurance provider to get a better understanding of the possible charges you will incur. Web ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  11. X-Rays - Multiple Languages

    Science.gov (United States)

    ... Expand Section Barium Swallow - 简体中文 (Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chest X-Ray - 简体中文 (Chinese, Simplified (Mandarin dialect)) ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray uses a very small dose of ionizing radiation to produce pictures of any bone in the ... of the body to a small dose of ionizing radiation to produce pictures of the inside of the ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. ... appliances, eye glasses and any metal objects or clothing that might interfere with the x-ray images. ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... abnormalities. This exam requires little to no special preparation. Tell your doctor and the technologist if there ... prepare? Most bone x-rays require no special preparation. You will be asked to remove some of ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... in metabolic conditions. assist in the detection and diagnosis of bone cancer . locate foreign objects in soft ... frequently compared to current x-ray images for diagnosis and disease management. top of page How is ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the baby. See the Safety page for more information about pregnancy and x-rays. top of page ... procedure varies. See the Safety page for more information about radiation dose. Women should always inform their ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? A bone x-ray examination itself ... available in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... white on the x-ray, soft tissue shows up in shades of gray and air appears black. ... who will discuss the results with you. Follow-up examinations may be necessary. Your doctor will explain ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... taken of the unaffected limb, or of a child's growth plate (where new bone is forming), for ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in varying degrees. Dense ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... procedure. You may experience discomfort from the cool temperature in the examination room. You may also find ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and ... facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... limb, or of a child's growth plate (where new bone is forming), for comparison purposes. When the ... Exams Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety How to Read Your Radiology Report ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... care is taken during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  5. X-ray screening materials

    International Nuclear Information System (INIS)

    Wardley, R.B.

    1981-01-01

    This invention relates to x-ray screening materials and especially to materials in sheet form for use in the production of, for example, protective clothing such as aprons and lower back shields, curtains, mobile screens and suspended shields. The invention is based on the observation that x-ray screening materials in sheet form having greater flexiblity than the hitherto known x-ray screening materials of the same x-ray absorber content can be produced if, instead of using a single sheet of filled sheet material of increased thickness, one uses a plurality of sheets of lesser thickness together forming a laminar material of the desired thickness and one bonds the individual sheets together at their edges and, optionally, at other spaced apart points away from the edges thereby allowing one sheet to move relative to another. (U.K.)

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ensures x-ray image quality. top of page Who interprets the results and how do I get ... report to your primary care or referring physician , who will discuss the results with you. Follow-up ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... no special preparation. Tell your doctor and the technologist if there is any possibility you are pregnant. ... should always inform their physician and x-ray technologist if there is any possibility that they are ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... is commonly used to diagnose fractured bones or joint dislocation. Bone x-rays are the fastest and ... to view and assess bone fractures, injuries and joint abnormalities. This exam requires little to no special ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray ...

  10. Miniature x-ray source

    Science.gov (United States)

    Trebes, James E.; Bell, Perry M.; Robinson, Ronald B.

    2000-01-01

    A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... taking our brief survey: Survey Do you have a personal story about radiology? Share your patient story ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... while the x-ray picture is taken to reduce the possibility of a blurred image. The technologist ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  14. Duodenal X-ray diagnostics

    International Nuclear Information System (INIS)

    Scheppach, W.

    1982-01-01

    The publication provides an overview of duodenal X-ray diagnostics with the aid of barium meals in 1362 patients. The introducing paragraphs deal with the topographic anatomy of the region and the methodics of X-ray investigation. The chapter entitled ''processes at the duodenum itself'' describes mainly ulcers, diverticula, congenital anomalies, tumors and inflammations. The neighbourhood processes comprise in the first place diseases having their origin at the pancreas and bile ducts. As a conclusion, endoscopic rectograde cholangio-pancreaticography and percutaneous transhepatic cholangiography are pointed out as advanced X-ray investigation methods. In the annex of X-ray images some of the described phenomena are shown in exemplary manner. (orig./MG) [de

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the oldest and most frequently used form of medical imaging. A bone x-ray makes images of any ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... radiation dose for this procedure varies. See the Safety page for more information about radiation dose. Women ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... instead of ionizing radiation to create diagnostic images, has also been useful for injuries around joints, and ...

  18. Accelerator x-ray sources

    CERN Document Server

    Talman, Richard

    2007-01-01

    This first book to cover in-depth the generation of x-rays in particle accelerators focuses on electron beams produced by means of the novel Energy Recovery Linac (ERL) technology. The resulting highly brilliant x-rays are at the centre of this monograph, which continues where other books on the market stop. Written primarily for general, high energy and radiation physicists, the systematic treatment adopted by the work makes it equally suitable as an advanced textbook for young researchers.

  19. X-ray tube target

    International Nuclear Information System (INIS)

    Weber, R.G.

    1980-01-01

    A target with an improved heat emissive surface for use in a rotating anode type x-ray tube is described. The target consists of a body having a first surface portion made of x-ray emissive material and a second surface portion made of a heat emissive material comprising at least one of hafnium boride, hafnium oxide, hafnium nitride, hafnium silicide, and hafnium aluminide. (U.K.)

  20. X-ray data processing

    OpenAIRE

    Powell, Harold R.

    2017-01-01

    The method of molecular structure determination by X-ray crystallography is a little over a century old. The history is described briefly, along with developments in X-ray sources and detectors. The fundamental processes involved in measuring diffraction patterns on area detectors, i.e. autoindexing, refining crystal and detector parameters, integrating the reflections themselves and putting the resultant measurements on to a common scale are discussed, with particular reference to the most c...

  1. Measurement of kVp, PPV and air kerma values in function of the electric current quantity and the focus-detector distance in one X-ray equipment

    International Nuclear Information System (INIS)

    Lucena, Rodrigo F. de; Potiens, Maria da Penha A.; Vivolo, Vitor

    2009-01-01

    The objective of this work was to study the behavior of the X-ray equipment Pantak/Seifert, model MXR-160/22 of the calibration laboratory of IPEN, LCI, operating in the diagnostic radiology radiation quality RQR 5 (70 kV). For this evaluation it was used a noninvasive meter PTW, Diavolt TM model. The measurements of kVp, PPV and Dose (air kerma), were made varying the electric current and distance between the focal point and the meter. This behavior is described in the literature and was expected in the analysis of the measurements for comparison purposes. For the tests where it was only increased the electric current it was waited a linear increase of the dose (air kerma), but not a variation in the kVp and PPV. The measurements had corresponded to the waited behavior, since the Dose (air kerma) measurements presented a linear increase with the increase of the electric current and the kVp and PPV values showed a variation less than 2%. In the corresponding measurements increasing the distance between focal point and meter, it was waited the exponentially decreasing of the Dose (air kerma) and again a small variation or no variation of the PPV and kVP with the increase of the distance. Over again the measurements corresponded to the expected, where the Dose (air kerma) decreased exponentially and the PPV and the kVp had a variation less than 1.5%. (author)

  2. Measurement of kVp, PPV and air kerma values in function of the electric current quantity and the focus-detector distance in one X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lucena, Rodrigo F. de; Potiens, Maria da Penha A.; Vivolo, Vitor, E-mail: rodrigoifusp@yahoo.com.b, E-mail: mppalbu@ipen.b, E-mail: vivolo@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP) Sao Paulo, SP (Brazil)

    2009-07-01

    The objective of this work was to study the behavior of the X-ray equipment Pantak/Seifert, model MXR-160/22 of the calibration laboratory of IPEN, LCI, operating in the diagnostic radiology radiation quality RQR 5 (70 kV). For this evaluation it was used a noninvasive meter PTW, Diavolt{sup TM} model. The measurements of kVp, PPV and Dose (air kerma), were made varying the electric current and distance between the focal point and the meter. This behavior is described in the literature and was expected in the analysis of the measurements for comparison purposes. For the tests where it was only increased the electric current it was waited a linear increase of the dose (air kerma), but not a variation in the kVp and PPV. The measurements had corresponded to the waited behavior, since the Dose (air kerma) measurements presented a linear increase with the increase of the electric current and the kVp and PPV values showed a variation less than 2%. In the corresponding measurements increasing the distance between focal point and meter, it was waited the exponentially decreasing of the Dose (air kerma) and again a small variation or no variation of the PPV and kVP with the increase of the distance. Over again the measurements corresponded to the expected, where the Dose (air kerma) decreased exponentially and the PPV and the kVp had a variation less than 1.5%. (author)

  3. Center for X-Ray Optics, 1992

    International Nuclear Information System (INIS)

    1993-08-01

    This report discusses the following topics: Center for X-Ray Optics; Soft X-Ray Imaging wit Zone Plate Lenses; Biological X-Ray microscopy; Extreme Ultraviolet Lithography for Nanoelectronic Pattern Transfer; Multilayer Reflective Optics; EUV/Soft X-ray Reflectometer; Photoemission Microscopy with Reflective Optics; Spectroscopy with Soft X-Rays; Hard X-Ray Microprobe; Coronary Angiography; and Atomic Scattering Factors

  4. Performance evaluation of 'conversional' X-ray machines in Tanzania

    International Nuclear Information System (INIS)

    Mwalongo, D.A.; Ngaile, J.E.; Sungita, Y.Y.

    2008-01-01

    Full text: Without periodic performance tests of the X-ray machines, optimal performance cannot be achieved. The aim of this study was therefore to evaluate the performance of the X-ray machine in order to check non-compliance with performance standards that may result in degradation of image quality or increase of unnecessary radiation doses to patients undergoing X-ray examinations in Tanzania. A total of 890 periodical performance tests were evaluated from 400 X-ray facilities conducted between 2000 and 2006.The performance tests were evaluated in terms of beam alignment and collimation using RMI test tools, kV accuracy and reproducibility, timer accuracy and reproducibility, output linearity, beam quality (HVL) using Victoreen non invasive test x-ray test device model 4000 M+ and tube leakage using Berthold ion chamber. In addition, dark room for each X-ray facility was evaluated in terms of film fog, film storage and cleanliness. The results showed that 86 % of the x-ray machine tested had beam alignment and collimation tests within the tolerance limits of 3 o and ± 2 % of focus detector distance; respectively; while 88 % of the machines tested had kV and timer reproducibility and accuracy tests within the tolerance limits of 4% and ± 10% respectively. The results further showed that 95 % of the machines tested had output linearity within tolerance limits of 10%, while HVL tests for all machines were above the minimum recommended limits. In addition the results showed that about 70% of the dark room facilities were adequate. The good performance of most X-ray machines were largely attributed to installation of new X-ray machines to all mainland districts, regions and referral hospitals through a joint project between the governments of Tanzania and the Netherlands. In view of the above, it is evident that most X-ray machines were within the recommended tolerance limits and hence optimum equipment performance. (author)

  5. X-ray equipment in medical diagnosis

    International Nuclear Information System (INIS)

    This document sets out requirements for the safe use of radiation emitting devices. Included in this code are sections for the specific guidance of the radiologist, the physician, the operator, and the health physicist

  6. X-ray imagery

    International Nuclear Information System (INIS)

    Dhez, P.

    1986-01-01

    Direct projection, pin diaphragm, lenses, mirrors and holography are used for X images. Each method is examined, radiation source problem is taken in account. For instance, the important role of synchrotron radiation in direct projection is noticed (angiography, microlithography, isotope separation). The pin diaphragm is used for laser-plasma images. Two use techniques of mirrors are presented: in grazing incidence (X-UV telescopes on satellite board) or in normal incidence (new ''laminated'' mirrors). This second technique, which uses interferences, seems to be the unique solution to equip optical cavities of X lasers. More classically, the multilayered mirrors are applicated to X microscopes (with synchrotron radiation). Lenses use diffraction. They lead to scanning X microscopes. At last, reconstruction methods of image are reviewed: different from computer are topography interferometry and holography. These three last ones are precised. In conclusion, the X optics application to two-dimensional material physics is recalled [fr

  7. Dual-energy X-ray absorptiometry for the simultaneous determination of Density and Moisture Content in Porous Structural Materials

    DEFF Research Database (Denmark)

    Hansen, Kurt Kielsgaard; Jensen, Signe Kamp; Gerward, Leif

    1999-01-01

    The paper describes the dual-energy x-ray equipment, which consists of a x-ray source, filters and a detector. The x-ray beam can be moved automatically in two dimensions relative to a fixed specimen. The purpose of the equipment is to measure simultaneously the density and moisture content...

  8. Ultrafast X-ray Sources

    International Nuclear Information System (INIS)

    Neil, George

    2010-01-01

    Since before the scattering of X-rays off of DNA led to the first understanding of the double helix structure, sources of X-rays have been an essential tool for scientists examining the structure and interactions of matter. The resolution of a microscope is proportional to the wavelength of light so x-rays can see much finer structures than visible light, down to single atoms. In addition, the energy of X-rays is resonant with the core atomic levels of atoms so with appropriate wavelengths the placement of specific atoms in a large molecule can be determined. Over 10,000 scientists use synchrotron sources, storage rings of high energy electrons, each year worldwide. As an example of such use, virtually every picture of a protein or drug molecule that one sees in the scientific press is a reconstruction based on X-ray scattering of synchrotron light from the crystallized form of that molecule. Unfortunately those pictures are static and proteins work through configuration (shape) changes in response to energy transfer. To understand how biological systems work requires following the energy flow to these molecules and tracking how shape changes drive their interaction with other molecules. We'd like to be able to freeze the action of these molecules at various steps along the way with an X-ray strobe light. How fast does it have to be? To actually get a picture of a molecule in a fixed configuration requires X-ray pulses as short as 30 femtoseconds (1/30 of a millionth of a millionth of a second). To capture the energy flow through changes in electronic levels requires a faster strobe, less than 1 femtosecond And to acquire such information in smaller samples with higher accuracy demands brighter and brighter X-rays. Unfortunately modern synchrotrons (dubbed 3rd Generation Light Sources) cannot deliver such short bright pulses of X-rays. An entirely new approach is required, linear-accelerator (linac-)-based light sources termed 4th or Next Generation Light Sources

  9. X-ray Echo Spectroscopy

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-01

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >108 ) with broadband ≃5 - 13 meV dispersing systems are introduced featuring more than 103 signal enhancement. The technique is general, applicable in different photon frequency domains.

  10. Imaging X-ray astronomy

    International Nuclear Information System (INIS)

    Elvis, M.

    1990-01-01

    The launch of the High Energy Astrophysical Observatory, more appealingly called the Einstein Observatory, marked one of the most revolutionary steps taken in astrophysics this century. Its greater sensitivity compared with earlier satellites and its ability to make high spacial and spectral resolution observations transformed X-ray astronomy. This book is based on a Symposium held in Cambridge, Massachusetts, to celebrate a decade of Einstein Observatory's achievements. It discusses the contributions that this satellite has made to each area of modern astrophysics and the diversity of the ongoing work based on Einstein data. There is a guide to each of the main data bases now coming on-line to increase the availability and to preserve this valuable archive for the future. A review of NASA's next big X-ray mission, AXAF, and a visionary program for novel X-ray astronomy satellites by Riccardo Giacconi conclude this wide-ranging volume. (author)

  11. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral X-ray apparatus which reduces the number of exposures necessary to obtain panoramic dental radiographs is described in detail. It comprises an electron gun, a tubular target carrier projecting from the gun along the beam axis and carrying at its distal end a target surrounded by a shield of X-ray opaque material. This shield extends forward and laterally of the target and has surfaces which define a wedge or cone-shaped radiation pattern delimited vertically by the root tips of the patient's teeth. A film holder is located externally of the patient's mouth. A disposable member can fit on the target carrier to depress the patient's tongue out of the radiation pattern and to further shield the roof of the mouth. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  12. X-ray fluorescence holography.

    Science.gov (United States)

    Hayashi, Kouichi; Happo, Naohisa; Hosokawa, Shinya; Hu, Wen; Matsushita, Tomohiro

    2012-03-07

    X-ray fluorescence holography (XFH) is a method of atomic resolution holography which utilizes fluorescing atoms as a wave source or a monitor of the interference field within a crystal sample. It provides three-dimensional atomic images around a specified element and has a range of up to a few nm in real space. Because of this feature, XFH is expected to be used for medium-range local structural analysis, which cannot be performed by x-ray diffraction or x-ray absorption fine structure analysis. In this article, we explain the theory of XFH including solutions to the twin-image problem, an advanced measuring system, and data processing for the reconstruction of atomic images. Then, we briefly introduce our recent applications of this technique to the analysis of local lattice distortions in mixed crystals and nanometer-size clusters appearing in the low-temperature phase of a shape-memory alloy.

  13. X-ray fluorescence holography

    International Nuclear Information System (INIS)

    Hayashi, Kouichi; Happo, Naohisa; Hosokawa, Shinya; Hu Wen; Matsushita, Tomohiro

    2012-01-01

    X-ray fluorescence holography (XFH) is a method of atomic resolution holography which utilizes fluorescing atoms as a wave source or a monitor of the interference field within a crystal sample. It provides three-dimensional atomic images around a specified element and has a range of up to a few nm in real space. Because of this feature, XFH is expected to be used for medium-range local structural analysis, which cannot be performed by x-ray diffraction or x-ray absorption fine structure analysis. In this article, we explain the theory of XFH including solutions to the twin-image problem, an advanced measuring system, and data processing for the reconstruction of atomic images. Then, we briefly introduce our recent applications of this technique to the analysis of local lattice distortions in mixed crystals and nanometer-size clusters appearing in the low-temperature phase of a shape-memory alloy. (topical review)

  14. Portable flash x-ray systems: applications and techniques

    International Nuclear Information System (INIS)

    Bryant, L.E. Jr.

    1976-01-01

    Three energies of portable flash x-ray equipment are described, and applications such as jetting and high explosive studies, bullet impact and casting of lead experiments are given as well as techniques for triggering and protection of equipment and film

  15. X-ray exposures to dental patients

    International Nuclear Information System (INIS)

    McKlveen, J.W.

    1980-01-01

    An elastic mask worn by patients and a skeleton encased in plastic were instrumented with LiF thermoluminescent dosimeters to determine radiation exposures delivered from full-face diagnostic dental X-rays. Measurements were made using various panoramic radiographical and periapical machines. Locations of interest included skin surface, eyes, upper and lower teeth and thyroid. Exposures in the 100 mR range were common and a maximum of over 6000 mR was measured in the teeth region during a full-face examination with a periapical unit. In general, exposures received from periapical equipment were several times those obtained from panoramic devices. (author)

  16. Requirements for use of nonmedical x-ray generators at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Busick, D.D. (comp.)

    1984-09-01

    The risks associated with use of x-ray equipment have long been recognized. While the relative frequency of x-ray damage is small, machine produced x-rays and large radiography sources continue to account for a large percentage of preventable radiation injuries reported worldwide. The intent of this report is to formalize SLAC's radiation safety program as it applies to radiation producing equipment (diffraction, fluorescence analysis and nondestructive testing). It does not apply to the two-mile linac, experimental areas or other x-ray producing equipment directly related to the high energy physics program. 4 refs., 3 figs., 1 tab.

  17. X-ray Emission from Solar Flares

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... Solar flares; X-ray detectors; X-ray line emission and continuum; break energy; microflares. Abstract. Solar X-ray Spectrometer (SOXS), the first space-borne solar astronomy experiment of India was designed to improve our current understanding of X-ray emission from the Sun in general and solar flares in ...

  18. History of x-ray astronomy

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. History of x-ray astronomy. Major X-ray Missions. 1970 :UHURU: detected 339 new sources (1st sky coverage). 1978: Einstein First x-ray imaging mission (>1000 sources). 1990: ROSAT; Soft X-ray imaging mission; detected 100,000 sources (deeper sky coverage) ...

  19. X-Ray Exam: Cervical Spine

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Cervical Spine KidsHealth / For Parents / X-Ray ... MRI): Lumbar Spine Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  20. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very ... limitations of Chest Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the ...

  1. X-Ray Exam: Neck (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Neck KidsHealth / For Parents / X-Ray Exam: ... Neck Enlarged Adenoids Croup Sinusitis Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  2. Semiconductor X-ray spectrometers

    International Nuclear Information System (INIS)

    Muggleton, A.H.F.

    1978-02-01

    An outline is given of recent developments in particle and photon induced x-ray fluorescence (XRF) analysis. Following a brief description of the basic mechanism of semiconductor detector operation a comparison is made between semiconductor detectors, scintillators and gas filled proportional devices. Detector fabrication and cryostat design are described in more detail and the effects of various device parameters on system performance, such as energy resolution, count rate capability, efficiency, microphony, etc. are discussed. The main applications of these detectors in x-ray fluorescence analysis, electron microprobe analysis, medical and pollution studies are reviewed

  3. Portable X-Ray Device

    Science.gov (United States)

    1983-01-01

    Portable x-ray instrument developed by NASA now being produced commercially as an industrial tool may soon find further utility as a medical system. The instrument is Lixiscope - Low Intensity X-Ray Imaging Scope -- a self-contained, battery-powered fluoroscope that produces an instant image through use of a small amount of radioactive isotope. Originally developed by Goddard Space Flight Center, Lixiscope is now being produced by Lixi, Inc. which has an exclusive NASA license for one version of the device.

  4. Overutilization of x-rays

    International Nuclear Information System (INIS)

    Abrams, H.L.

    1979-01-01

    In this article on the overutilization of x-rays the author defines the term overutilization as excessive irradiation per unit of diagnostic information, therapeutic impact, or health outcome. Three main factors are described which lead to overutilization of x-rays: excessive radiation per film; excessive films per examination; and excessive examinations per patient. Topics discussed which influence the excessive examinations per patient are: the physician's lack of knowledge; undue dependence; lack of screening by radiologists; the physician's need for action and certainty; patient demand; reimbursement policies; institutional requirements; preventive medicine; defensive medicine; and the practice of radiology by nonradiologists

  5. X-ray data processing.

    Science.gov (United States)

    Powell, Harold R

    2017-10-31

    The method of molecular structure determination by X-ray crystallography is a little over a century old. The history is described briefly, along with developments in X-ray sources and detectors. The fundamental processes involved in measuring diffraction patterns on area detectors, i.e. autoindexing, refining crystal and detector parameters, integrating the reflections themselves and putting the resultant measurements on to a common scale are discussed, with particular reference to the most commonly used software in the field. © 2017 The Author(s).

  6. Chemical characterization of minerals from a commercial vitamin supplement using X-ray fluorescence and a portable equipment; Caracterizacao quimica de minerais em um suplemento vitaminico comercial por fluorescencia de raios X com equipamento portatil

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Fabio; Parreira, Paulo S.; Appoloni, Carlos R., E-mail: bonn@uel.b [Universidade Estadual de Londrina (UEL), PR (Brazil). Dept. de Fisica. Lab. de Fisica Nuclear Aplicada; Melquiades, Fabio L., E-mail: fmelquiades@unicentro.b [Universidade Estadual do Centro Oeste (UNICENTRO), Guarapuava, PR (Brazil). Dept. de Fisica

    2007-07-01

    Vitamins and mineral supplements are largely consumed by adult population; nevertheless, research has indicated that an inadequate ingestion of supplements may be more harmful than beneficial to the human body. This way, it is important to know the elemental chemical composition of such products. The technique employed in this work was energy dispersive X-ray fluorescence (EDXRF), using a portable equipment. The validation of the method was carried out by analysing two certified reference materials: SRM-1832 e 1833. Three samples of coated compressed tablets were selected, ground and then reconstructed in the form of pastile. The concentrations found, and their respective experimental errors, in mug g{sup -1}, were: Cl (22.4 +- 4.40), K (26.0 +- 1.15), Ca (148.7 +- 3.25), Mn (2.9 +- 0.54), Fe (6.3 +- 0.36), Cu(4.0 +- 0.14), Zn (70.9 +- 1.88), Se (0.1 +- 0.01), Br (0.2 +- 0.02), Sr (0.2 +- 0.01) and Mo (0.1 +- 0.01). It was possible to determine the detection limit for the elements Ca (0.29), Fe (0.09), Cu(0.05) e Zn(0.22), in mug g{sup -1}. From the eleven elements found in the analysed supplement sample, three (Cl, Br e Sr) were not mentioned in the product printed instructions (bull) and other three mentioned elements (V, Cr, Ni) have not been detected.

  7. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures; Sistema de medicao camara de ionizacao-eletrometro para ensaios de protecao radiologica em equipamentos de raios X para procedimentos intervencionistas

    Energy Technology Data Exchange (ETDEWEB)

    Bottaro, Marcio

    2012-07-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10{sup 8} V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW Registered-Sign platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  8. Quality assurance for diagnostic X-ray machines in Tanzania

    International Nuclear Information System (INIS)

    Sungita, Y.Y.; Mdoe, S.L.; Ngatunga, J.; Kitosi, A.E.; Muhogora, W.E.

    1998-01-01

    In this presentation it is being discussed a close relationship between the prevention of accidents involving apparatus that generates the ionizing radiation (x-ray tubes etc.) and the need to perform quality control procedures and make follow-up corrective maintenance procedures. A summary of results of quality control performance of x-ray machines in certain centers in Tanzania is tabled and measures to overcome some of the observed problems are recommended. The number of X-ray units inspected were 219, out of which 123 were working, 75 were out of order, 6 units were not yet installed and those which are working with faulty parts were 15. The performance of quality assurance for X-Ray units (57) tested showed that 36.8% didn't qualify. About 80% of these equipment are more than 15 years old. (author)

  9. Beam conditioning multilayer optics for laboratory x-ray sources

    Science.gov (United States)

    Platonov, Yuriy; Verman, Boris; Jiang, Licai; Kim, Bonglea

    2015-08-01

    Practically, all modern x-ray diffractometers, SAXS, TXRF systems and many other laboratory X-ray instruments are equipped with multilayer X-ray optics. It is due to a much higher flux these instruments have comparing with those having no optics or having a grazing incidence optics without multilayer coatings. There are variety of the multilayer optics designs - from one bounce collimating parabolic mirror to four corners double bounce focusing mirrors. Design of multilayer optics depends on application, X-ray source parameters, requirements on divergence, focal spot, available room for the optics, manufacturing capability and cost. Key characteristics of the optics, requirements on multilayers d-spacing accuracy, optics slope errors, and substrates surface roughness are discussed in the paper. Different optics designs are considered including recently developed optics for a laboratory topography system and a Hybrid optics combining multilayer and crystal optics for XRR and XRD.

  10. System for calibration of instruments of x-ray measurement (CIR-X) applying the PGCS

    International Nuclear Information System (INIS)

    Gaytan G, E.; Rivero G, T.; Cruz E, P.; Tovar M, V.M.; Vergara M, F.J.

    2007-01-01

    The Department of Metrology of Ionizing Radiations of the ININ carries out calibration of instruments for X-ray measurement that determine the operation parameters in X-ray diagnostic machines of the health and private sectors. To facilitate this task, the Department of Automation and Instrumentation developed a system for acquisition and signals processing coming from a reference voltage divider with traceability at NIST that is connected directly to the X-rays tube. The system is integrated by the X-ray unit, the X-ray measurement equipment Dynalizer IIIU of RADCAL, a data acquisition card, a personal computer and the acquisition software and signals processing. (Author)

  11. Analytical X-ray microscopy using laboratory sources: Method and results

    International Nuclear Information System (INIS)

    Wulveryck, J.M.; Odof, S.; Patat, J.M.; Mouze, D.

    2000-01-01

    The implementation of X-ray imaging techniques (X-Ray Projection Microscopy or X-Ray Microtomography) for analytical purpose with laboratory equipment is not easily obtainable, due to the use of polychromatic X-ray sources. To overcome this drawback, we propose here a mathematical technique based upon the calculation of the X-ray emission spectra and the knowledge of the spectral response of the camera. For example, we show that the composition of a ternary sample can be deduced from two images measurements recorded from two primary radiation. The accuracy of the method is discussed

  12. X-ray microscopes at BESSY II

    International Nuclear Information System (INIS)

    Guttmann, P.; Niemann, B.; Thieme, J.; Wiesemann, U.; Rudolph, D.; Schmahl, G.

    2000-01-01

    The undulator U41 at BESSY II will be used as source for X-ray microscopes. An overview of the X-ray microscopy area is presented. After finishing the construction phase a transmission X-ray microscope, a scanning transmission X-ray microscope and an X-ray test chamber will be available. The transmission X-ray microscope will allow investigations with high lateral resolution at moderate energy resolution while the scanning transmission X-ray microscope will allow high energy resolution at moderate lateral resolution of the same specimen

  13. Illumination system for X-ray lithography

    International Nuclear Information System (INIS)

    Buckley, W.D.

    1989-01-01

    An X-ray lithography system is described, comprising: a point source of X-Ray radiation; a wafer plane disposed in spaced relation to the point source of X-Ray radiation; a mask disposed between the point source of X-Ray radiation and the wafer plane whereby X-Ray radiation from the point source of X-ray radiation passes through the mask to the water plane; and X-Ray absorbent means mounted between the point source of X-Ray radiation and the wafer plane, the X-Ray absorbent means being of quadratically absorption from maximum absorption at the center to minimum absorption at the edge so as to have a radial absorption gradient profile to compensate for radial flux variation of the X-Ray radiation

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the table in the area of the body being imaged. When necessary, sandbags, pillows or other positioning devices will be used to help you ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) ... imaged receive minimal radiation exposure. top of page ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ...

  16. X-Ray Diffractive Optics

    Science.gov (United States)

    Dennis, Brian; Li, Mary; Skinner, Gerald

    2013-01-01

    X-ray optics were fabricated with the capability of imaging solar x-ray sources with better than 0.1 arcsecond angular resolution, over an order of magnitude finer than is currently possible. Such images would provide a new window into the little-understood energy release and particle acceleration regions in solar flares. They constitute one of the most promising ways to probe these regions in the solar atmosphere with the sensitivity and angular resolution needed to better understand the physical processes involved. A circular slit structure with widths as fine as 0.85 micron etched in a silicon wafer 8 microns thick forms a phase zone plate version of a Fresnel lens capable of focusing approx. =.6 keV x-rays. The focal length of the 3-cm diameter lenses is 100 microns, and the angular resolution capability is better than 0.1 arcsecond. Such phase zone plates were fabricated in Goddard fs Detector Development Lab. (DDL) and tested at the Goddard 600-microns x-ray test facility. The test data verified that the desired angular resolution and throughput efficiency were achieved.

  17. X-rays from stars

    Science.gov (United States)

    Güdel, Manuel

    2004-07-01

    Spectroscopic studies available from Chandra and XMM-Newton play a pivotal part in the understanding of the physical processes in stellar (magnetic and non-magnetic) atmospheres. It is now routinely possible to derive densities and to study the influence of ultraviolet radiation fields, both of which can be used to infer the geometry of the radiating sources. Line profiles provide important information on bulk mass motions and attenuation by neutral matter, e.g. in stellar winds. The increased sensitivity has revealed new types of X-ray sources in systems that were thought to be unlikely places for X-rays: flaring brown dwarfs, including rather old, non-accreting objects, and terminal shocks in jets of young stars are important examples. New clues concerning the role of stellar high-energy processes in the modification of the stellar environment (ionization, spallation, etc.) contribute significantly to our understanding of the "astro-ecology" in forming planetary systems. Technological limitations are evident. The spectral resolution has not reached the level where bulk mass motions in cool stars become easily measurable. Higher resolution would also be important to perform X-ray "Doppler imaging" in order to reconstruct the 3-D distribution of the X-ray sources around a rotating star. Higher sensitivity will be required to perform high-resolution spectroscopy of weak sources such as brown dwarfs or embedded pre-main-sequence sources. A new generation of satellites such as Constellation-X or XEUS should pursue these goals.

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... This ensures that those parts of a patient's body not being imaged receive minimal radiation ... x-ray images are among the clearest, most detailed views of ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... about radiology? Share your patient story here Images ... content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ...

  20. High resolution X ray spectroscopy

    International Nuclear Information System (INIS)

    Bartiromo, R.

    1987-01-01

    This paper is devoted to a detailed discussion of the physical processes which are responsible for the emission spectra of H-like and He-like ion of high Z impurities in low density plasmas. The application of high resolution X-ray spectroscopy to the diagnostic of tokamak plasmas is also discussed and examples of the results obtained are presented

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  3. X-ray image coding

    International Nuclear Information System (INIS)

    1974-01-01

    The invention aims at decreasing the effect of stray radiation in X-ray images. This is achieved by putting a plate between source and object with parallel zones of alternating high and low absorption coefficients for X-radiation. The image is scanned with the help of electronic circuits which decode the signal space coded by the plate, thus removing the stray radiation

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... any possibility that they are pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. A Word About Minimizing ... imaging tests and treatments have special pediatric considerations. The teddy ...

  5. X-rays and magnetism

    International Nuclear Information System (INIS)

    Fischer, Peter; Ohldag, Hendrik

    2015-01-01

    Magnetism is among the most active and attractive areas in modern solid state physics because of intriguing phenomena interesting to fundamental research and a manifold of technological applications. State-of-the-art synthesis of advanced magnetic materials, e.g. in hybrid structures paves the way to new functionalities. To characterize modern magnetic materials and the associated magnetic phenomena, polarized x-rays have emerged as unique probes due to their specific interaction with magnetic materials. A large variety of spectroscopic and microscopic techniques have been developed to quantify in an element, valence and site-sensitive way properties of ferro-, ferri-, and antiferromagnetic systems, such as spin and orbital moments, and to image nanoscale spin textures and their dynamics with sub-ns time and almost 10 nm spatial resolution. The enormous intensity of x-rays and their degree of coherence at next generation x-ray facilities will open the fsec time window to magnetic studies addressing fundamental time scales in magnetism with nanometer spatial resolution. This review will give an introduction into contemporary topics of nanoscale magnetic materials and provide an overview of analytical spectroscopy and microscopy tools based on x-ray dichroism effects. Selected examples of current research will demonstrate the potential and future directions of these techniques. (report on progress)

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ...

  7. Stellar X-Ray Polarimetry

    Science.gov (United States)

    Swank, J.

    2011-01-01

    Most of the stellar end-state black holes, pulsars, and white dwarfs that are X-ray sources should have polarized X-ray fluxes. The degree will depend on the relative contributions of the unresolved structures. Fluxes from accretion disks and accretion disk corona may be polarized by scattering. Beams and jets may have contributions of polarized emission in strong magnetic fields. The Gravity and Extreme Magnetism Small Explorer (GEMS) will study the effects on polarization of strong gravity of black holes and strong magnetism of neutron stars. Some part of the flux from compact stars accreting from companion stars has been reflected from the companion, its wind, or accretion streams. Polarization of this component is a potential tool for studying the structure of the gas in these binary systems. Polarization due to scattering can also be present in X-ray emission from white dwarf binaries and binary normal stars such as RS CVn stars and colliding wind sources like Eta Car. Normal late type stars may have polarized flux from coronal flares. But X-ray polarization sensitivity is not at the level needed for single early type stars.

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... time. Follow-up examinations are sometimes the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest way for a ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... to current x-ray images for diagnosis and disease management. top of page How is the procedure ...

  10. X-ray absorption holography

    Czech Academy of Sciences Publication Activity Database

    Kopecký, Miloš; Lausi, A.; Bussetto, E.; Kub, Jiří; Savoia, A.

    2002-01-01

    Roč. 88, č. 18 (2002), s. 185503-1 - 185503-3 ISSN 0031-9007 R&D Projects: GA MŠk LN00A100 Institutional research plan: CEZ:AV0Z1010921 Keywords : x-ray holography Subject RIV: BH - Optics, Masers, Lasers Impact factor: 7.323, year: 2002

  11. Compact x-ray source and panel

    Science.gov (United States)

    Sampayon, Stephen E [Manteca, CA

    2008-02-12

    A compact, self-contained x-ray source, and a compact x-ray source panel having a plurality of such x-ray sources arranged in a preferably broad-area pixelized array. Each x-ray source includes an electron source for producing an electron beam, an x-ray conversion target, and a multilayer insulator separating the electron source and the x-ray conversion target from each other. The multi-layer insulator preferably has a cylindrical configuration with a plurality of alternating insulator and conductor layers surrounding an acceleration channel leading from the electron source to the x-ray conversion target. A power source is connected to each x-ray source of the array to produce an accelerating gradient between the electron source and x-ray conversion target in any one or more of the x-ray sources independent of other x-ray sources in the array, so as to accelerate an electron beam towards the x-ray conversion target. The multilayer insulator enables relatively short separation distances between the electron source and the x-ray conversion target so that a thin panel is possible for compactness. This is due to the ability of the plurality of alternating insulator and conductor layers of the multilayer insulators to resist surface flashover when sufficiently high acceleration energies necessary for x-ray generation are supplied by the power source to the x-ray sources.

  12. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  13. X-ray film reject rate analysis at eight selected government hospitals ...

    African Journals Online (AJOL)

    admin

    Objective: The purpose of this research was to identify the main causes of film faults as well as the pattern and magnitude of film ... ensure satisfactory performance of radiographic x-ray equipment on a day-to-day basis. Quality assurance programs are primarily concerned with maintaining of X- ray imaging equipment at the ...

  14. Verification of industrial x-ray machine: MINTs experience

    International Nuclear Information System (INIS)

    Aziz Amat; Saidi Rajab; Eesan Pasupathi; Saipo Bahari Abdul Ratan; Shaharudin Sayuti; Abd Nassir Ibrahim; Abd Razak Hamzah

    2005-01-01

    Radiation and electrical safety of the industrial x-ray equipment required to meet Atomic Energy Licensing Board(AELB) guidelines ( LEM/TEK/42 ) at the time of installation and subsequently a periodic verification should be ensured. The purpose of the guide is to explain the requirements employed in conducting the test on industrial x-ray apparatus and be certified in meeting with our local legislative and regulation. Verification is aimed to provide safety assurance information on electrical requirements and the minimum radiation exposure to the operator. This regulation is introduced on new models imported into the Malaysian market. Since June, 1997, Malaysian Institute for Nuclear Technology Research (MINT) has been approved by AELB to provide verification services to private company, government and corporate body throughout Malaysia. Early January 1997, AELB has made it mandatory that all x-ray equipment for industrial purpose (especially Industrial Radiography) must fulfill certain performance test based on the LEM/TEK/42 guidelines. MINT as the third party verification encourages user to improve maintenance of the equipment. MINT experiences in measuring the performance on intermittent and continuous duty rating single-phase industrial x-ray machine in the year 2004 indicated that all of irradiating apparatus tested pass the test and met the requirements of the guideline. From MINT record, 1997 to 2005 , three x-ray models did not meet the requirement and thus not allowed to be used unless the manufacturers willing to modify it to meet AELB requirement. This verification procedures on electrical and radiation safety on industrial x-ray has significantly improved the the maintenance cultures and safety awareness in the usage of x-ray apparatus in the industrial environment. (Author)

  15. Evaluation and characterization of digital X-ray equipment for paediatric cardiology in the Hospital Gregorio Maranon; Evaluacion y caracterizacion de la dinamica de trabajo y de la dosis recibida por el paciente en la sala de hemodinamica infantil del Hospital General Universitario Gregorio Maranon

    Energy Technology Data Exchange (ETDEWEB)

    Calama Santiago, J. A.; Gonzalez Ruiz, C.; Infante Utrilla, M. A.; Zanfano Hidalgo, R.; Penedo cobos, J. M.; Sierra Diaz, F.; Olivares Munoz, M. P.

    2006-07-01

    The purchase of a digital X-Ray equipment specific for paediatric cardiology in 2003 has allowed a careful examination of the technical characteristics of these patients. This data review includes the analysis of a dose index with several variable factors such as weight, size and age of patients, purpose, type and characteristics of the study and its development over time as a results of the experience gained by the staff involved. (Author)

  16. Shielding requirements for diagnostic and therapeutic X-ray apparatus in South Australia: regulatory requirements, specifications and assessment of X-ray rooms

    International Nuclear Information System (INIS)

    Bibbo, G.

    1988-01-01

    In South Australia the shielding requirements for diagnostic and therapeutic x-ray apparatus depend on the maximum power output of the equipment regardless of workload, usage or occupancy. The method of calculating the required shielding is discussed and the procedure for assessing the degree of radiation protection of the x-ray room once the apparatus has been installed is outlined

  17. Feasibility study on X-ray source with pinhole imaging method

    International Nuclear Information System (INIS)

    Qiu Rui; Li Junli

    2007-01-01

    In order to verify the feasibility of study on X-ray source with pinhole imaging method, and optimize the design of X-ray pinhole imaging system, an X-ray pinhole imaging equipment was set up. The change of image due to the change of the position and intensity of X-ray source was estimated with mathematical method and validated with experiment. The results show that the change of the spot position and gray of the spot is linearly related with the change of the position and intensity of X-ray source, so it is feasible to study X-ray source with pinhole imaging method in this application. The results provide some references for the design of X-ray pinhole imaging system. (authors)

  18. Development of a carbon nanotube based micro-focus X-ray tube

    International Nuclear Information System (INIS)

    Jung, H. K.; Cheong, Y. M.; Lee, Y. S.; Choi, Y. S.; Joo, Y. S.; Park, S. K.; Sim, C. M.

    2010-02-01

    The electron field-emission properties of carbon nanotubes (CNTs) enable the fabrication of new cold cathodes for many X-ray instruments. The utilization of these cathodes is an attractive alternative for thermo-ionic cathodes for generating X-rays. CNT has been successfully incorporated into the x-ray tube. CNT fibers offer some advantages over CNT coating for a new generation of X-ray tube, with low power consumption, long lifetime due to the unraveling effect, and high resolution due to the micro-scale emission area. Further research is needed for CNT fiber for x-ray tube in order to increase the stability and consistency for an application to a portable x-ray machine and high resolution x-ray equipment

  19. 3rd International Conference on X-ray Technique

    Science.gov (United States)

    Potrakhov, N. N.; Gryaznov, A. Yu; Lisenkov, A. A.; Kostrin, D. K.

    2017-02-01

    In this preface a brief history, modern aspects and future tendencies in development of the X-ray technique as seen from the 3rd International Conference on X-ray Technique that was held on 24-25 November 2016 in Saint Petersburg, Russia are described On 24-25 November 2016 in Saint Petersburg on the basis of Saint Petersburg State Electrotechnical University “LETI” n. a. V. I. Ulyanov (Lenin) was held the 3rd International Conference on X-ray Technique. The tradition to hold a similar conference in our country was laid in Soviet times. The last of them, the All-Union Conference on the Prospects of X-ray Tubes and Equipment was organized and held more than a quarter century ago - on 21-23 November 1999, at the initiative and under the leadership of the chief engineer of the Leningrad association of electronic industry “Svetlana” Borovsky Alexander Ivanovich and the chief of special design bureau of X-ray devices of “Svetlana” Shchukin Gennady Anatolievich. The most active part in the organization and work of the conference played members of the department of X-ray and electron beam instruments of Leningrad Electrotechnical Institute “LETI” (the former name of Saint Petersburg State Electrotechnical University “LETI”), represented by head of the department professor Ivanov Stanislav Alekseevich.

  20. Treatment of foods with high-energy X rays

    International Nuclear Information System (INIS)

    Cleland, M.R.; Meissner, J.; Herer, A.S.; Beers, E.W.

    2001-01-01

    The treatment of foods with ionizing energy in the form of gamma rays, accelerated electrons, and X rays can produce beneficial effects, such as inhibiting the sprouting in potatoes, onions, and garlic, controlling insects in fruits, vegetables, and grains, inhibiting the growth of fungi, pasteurizing fresh meat, poultry, and seafood, and sterilizing spices and food additives. After many years of research, these processes have been approved by regulatory authorities in many countries and commercial applications have been increasing. High-energy X rays are especially useful for treating large packages of food. The most attractive features are product penetration, absorbed dose uniformity, high utilization efficiency and short processing time. The ability to energize the X-ray source only when needed enhances the safety and convenience of this technique. The availability of high-energy, high-power electron accelerators, which can be used as X-ray generators, makes it feasible to process large quantities of food economically. Several industrial accelerator facilities already have X-ray conversion equipment and several more will soon be built with product conveying systems designed to take advantage of the unique characteristics of high-energy X rays. These concepts will be reviewed briefly in this paper

  1. X-ray cardiovascular examination apparatus

    International Nuclear Information System (INIS)

    1977-01-01

    An X-ray source is mounted in an enclosure for angulating longitudinally about a horizontal axis. An X-ray-permeable, patient-supporting table is mounted on the top of the enclosure for executing lateral and longitudinal movements. An X-ray image-receiving device such as an X-ray image intensifier is mounted above the table on a vertically movable arm which is on a longitudinally movable carriage. Electric control means are provided for angulating the X-ray source and image intensifier synchronously as the image intensifier system is shifted longitudinally or vertically such that the central ray from the X-ray source is kept intensifier

  2. Effective X-ray beam size measurements of an X-ray tube and polycapillary X-ray lens system using a scanning X-ray fluorescence method

    Energy Technology Data Exchange (ETDEWEB)

    Gherase, Mihai R., E-mail: mgherase@csufresno.edu; Vargas, Andres Felipe

    2017-03-15

    Size measurements of an X-ray beam produced by an integrated polycapillary X-ray lens (PXL) and X-ray tube system were performed by means of a scanning X-ray fluorescence (SXRF) method using three different metallic wires. The beam size was obtained by fitting the SXRF data with the analytical convolution between a Gaussian and a constant functions. For each chemical element in the wire an effective energy was calculated based on the incident X-ray spectrum and its photoelectric cross section. The proposed method can be used to measure the effective X-ray beam size in XRF microscopy studies.

  3. Center for X-Ray Optics, 1986

    International Nuclear Information System (INIS)

    1987-07-01

    The Center for X-Ray Optics has made substantial progress during the past year on the development of very high resolution x-ray technologies, the generation of coherent radiation at x-ray wavelengths, and, based on these new developments, had embarked on several scientific investigations that would not otherwise have been possible. The investigations covered in this report are topics on x-ray sources, x-ray imaging and applications, soft x-ray spectroscopy, synchrotron radiation, advanced light source and magnet structures for undulators and wigglers

  4. X-ray diagnostic in gas discharge

    International Nuclear Information System (INIS)

    Chen Suhe; Wang Dalun; Cui Gaoxian; Wang Mei; Fu Yibei; Zhang Xinwei; Zhang Wushou

    1995-01-01

    X rays were observed when the anomalous phenomenon in the metal loaded with deuterium studied by the gas-discharge method. Therefore the X-ray energy spectra were measured by the absorption method, the specific X-ray approach and the NaI scintillation counter, while X-ray intensity was estimated by using 7 Li thermoluminescent foils. The X-ray average energy measured by the absorption method is 27.6 +- 2.1 keV, which is fitted within the error extent to 26.0 +-2.4 keV monoenergetic X rays measured by the NaI scintillation counter

  5. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube

    International Nuclear Information System (INIS)

    Kayser, Y.; Błachucki, W.; Dousse, J.-Cl.; Hoszowska, J.; Neff, M.; Romano, V.

    2014-01-01

    The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO 2 optical fibers

  6. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube.

    Science.gov (United States)

    Kayser, Y; Błachucki, W; Dousse, J-Cl; Hoszowska, J; Neff, M; Romano, V

    2014-04-01

    The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO2 optical fibers.

  7. Radiation processing with high-energy X-rays

    International Nuclear Information System (INIS)

    Cleland, Marshall R.; Stichelbaut, Frederic

    2009-01-01

    The physical, chemical or biological characteristics of selected commercial products and materials can be improved by radiation processing. The ionizing energy can be provided by accelerated electrons with energies between 75 keV and 10 MeV, gamma rays from cobalt-60 with average energies of 1.25 MeV or X-rays with maximum energies up to 7.5 MeV. Electron beams are preferred for thin products, which are processed at high speeds. Gamma rays are used for products that are too thick for treatment with electron beams. High-energy X-rays can also be used for these purposes because their penetration in solid materials is similar to or even slightly greater than that of gamma rays. Previously, the use of X-rays had been inhibited by their slower processing rates and higher costs when compared with gamma rays. Since then, the price of cobalt-60 sources has been increased and the radiation intensity from high-energy, high-power X-ray generators has also increased. For facilities requiring at least 2 MCi of cobalt-60, the capital and operating costs of X-ray facilities with equivalent processing rates can be less than that of gamma-ray irradiators. Several high-energy electron beam facilities have been equipped with removable X-ray targets so that irradiation processes can be done with either type of ionizing energy. A new facility is now being built which will be used exclusively in the X-ray mode to sterilize medical products. Operation of this facility will show that high-energy, high-power X-ray generators are practical alternatives to large gamma-ray sources. (author)

  8. Evaluation of the shielding of dental X-rays units

    International Nuclear Information System (INIS)

    Medrano, E.; Vega C, H. R.; Letechipia de L, C.; Hernandez D, V. M.; Salas L, M. A.

    2014-08-01

    The capacity of the walls of the dental radio-diagnostic rooms has been determined, to diminish the dose levels during the use of the X-rays equipment s. The study was carried out in the Dentistry Academic Unit of the campus Siglo X XI of the Universidad Autonoma de Zacatecas. The X-rays equipment s are a learning tool for the dentistry students and they are also used for offering health services to the population; for this reason is important to verify that the dose levels outside of the room walls are safe. During the evaluation process were used conservative approaches without prejudice of the thickness necessary in benefit of the radiological protection. Of the evaluation was found that all the walls satisfy their function thoroughly like barriers against the X-rays. (Author)

  9. Archaeochemical study of the ancient Egyptian glass from the collection of the Ancient Egyptian Museum, Tokyo using a newly developed portable X-ray fluorescence spectrometer equipped with a CMOS camera

    International Nuclear Information System (INIS)

    Kikugawa, Tadashi; Abe, Yoshinari; Nakai, Izumi; Sanada, Takashi

    2009-01-01

    An improved version of the portable X-ray fluorescence spectrometer, OURSTEX FA-IV was manufactured; its weight was reduced to 16 kg. and a CMOS camera was installed for pinpoint analysis of the artifacts. By applying this spectrometer to element analysis of ancient Egyptian glass in the collection of the Ancient Egyptian Museum, Shibuya, Tokyo, copper and cobalt were identified in the blue colorant of the glasses. A combination with a portable X-ray powder diffractometer was also examined, and disclosed lead antimonate Pb 2 Sb 2 O 7 and lead stannate PbSnO 3 as the yellow colorants and calcium antimonite Ca 2 Sb 2 O 7 as the white colorant of the glass. The results provide new examples of historical use of cobalt alum in the Roman period (A.D.2 C.) which was believed to be used only in the New Kingdom (B.C.14-11 C.), and that of lead stannate PbSnO 3 in the A.D.2 C, which was thought to be used after A.D.4 C. Further, XRF imaging utilizing laboratory X-ray microscope or synchrotron radiation X-ray microbeam was also applied to reveal colorants of yellow, blue, white and black colors used in complex archaeological patterns. (author)

  10. X-ray tube arrangements

    International Nuclear Information System (INIS)

    Gillard, R.G.

    1980-01-01

    A technique for ensuring the rapid correction of both amplitude and offset errors in the deflectional movement of an electron beam along an X-ray emissive target is described. The movement is monitored at at least two positions during a sweep and differences, between the two movements and a desired movement, at these positions are combined in different proportions to produce a corrective servo signal. Such arrangements find application, for example, in computerised tomographic scanners. (author)

  11. X-ray Sensitive Material

    Science.gov (United States)

    2015-12-01

    Reference 3), inorganic semiconductors (silicon [Si], cadmium zinc telluride [CdZnTe]) (Reference 4) and selenium (References 5 and 6), Ne-Xe...data showing photocurrent generation. Reports on other X-ray photoconductors, such as amorphous selenium , typically show such data (Reference 34). We...that BiI3 content does contribute to surface discharge; however, further work is warranted to measure the photocurrent. Selenium films used for

  12. Diffractive X-ray Telescopes

    OpenAIRE

    Skinner, Gerald K.

    2010-01-01

    Diffractive X-ray telescopes using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution several orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro-arc-seconds or even better, that would allow, for example, imaging of the distorted space- time in the immediate vicinity of the super...

  13. Smart X-ray optics

    International Nuclear Information System (INIS)

    Michette, A G; Pfauntsch, S J; Sahraei, S; Shand, M; Morrison, G R; Hart, D; Vojnovic, B; Stevenson, T; Parkes, W; Dunare, C; Willingale, R; Feldman, C; Button, T; Zhang, D; Rodriguez-Sanmartin, D; Wang, H

    2009-01-01

    This paper describes reflective adaptive/active optics for applications including studies of biological radiation damage. The optics work on the polycapillary principle, but use arrays of channels in thin silicon. For optimum performance the x-rays should reflect once off a channel wall in each of two successive arrays. This reduces aberrations since then the Abbe sine condition is approximately satisfied. Adaptivity is achieved by flexing the arrays via piezo actuation, providing further aberration reduction and controllable focal length.

  14. X-Ray Crystallography Reagent

    Science.gov (United States)

    Morrison, Dennis R. (Inventor); Mosier, Benjamin (Inventor)

    2003-01-01

    Microcapsules prepared by encapsulating an aqueous solution of a protein, drug or other bioactive substance inside a semi-permeable membrane by are disclosed. The microcapsules are formed by interfacial coacervation under conditions where the shear forces are limited to 0-100 dynes per square centimeter at the interface. By placing the microcapsules in a high osmotic dewatering solution. the protein solution is gradually made saturated and then supersaturated. and the controlled nucleation and crystallization of the protein is achieved. The crystal-filled microcapsules prepared by this method can be conveniently harvested and stored while keeping the encapsulated crystals in essentially pristine condition due to the rugged. protective membrane. Because the membrane components themselves are x-ray transparent, large crystal-containing microcapsules can be individually selected, mounted in x-ray capillary tubes and subjected to high energy x-ray diffraction studies to determine the 3-D smucture of the protein molecules. Certain embodiments of the microcapsules of the invention have composite polymeric outer membranes which are somewhat elastic, water insoluble, permeable only to water, salts, and low molecular weight molecules and are structurally stable in fluid shear forces typically encountered in the human vascular system.

  15. National synchrotron light source user's manual: Guide to the VUV and x-ray beamlines: Third edition

    International Nuclear Information System (INIS)

    Gmuer, N.F.; Thomlinson, W.; White-DePace, S.

    1989-01-01

    This report contains information on the following topics: A Word on the Writing of Beamline Descriptions; Beamline Equipment Utilization for General Users; the Vacuum Ultraviolet (VUV) Storage Ring and Beamlines; VUV Beamline Descriptions--An Explanation; VUV Beamline Descriptions; X-Ray Storage Ring and Beamlines; X-Ray Beamline Descriptions--An Explanation; and X-Ray Beamline Descriptions

  16. National synchrotron light source user's manual: Guide to the VUV and x-ray beamlines: Third edition

    Energy Technology Data Exchange (ETDEWEB)

    Gmuer, N.F.; Thomlinson, W.; White-DePace, S.

    1989-01-01

    This report contains information on the following topics: A Word on the Writing of Beamline Descriptions; Beamline Equipment Utilization for General Users; the Vacuum Ultraviolet (VUV) Storage Ring and Beamlines; VUV Beamline Descriptions--An Explanation; VUV Beamline Descriptions; X-Ray Storage Ring and Beamlines; X-Ray Beamline Descriptions--An Explanation; and X-Ray Beamline Descriptions.

  17. Effects of X-rays spectrum on the dose

    International Nuclear Information System (INIS)

    Rodriguez I, J. L.; Hernandez A, P. L.; Vega C, H. R.; Rivera M, T.

    2015-10-01

    The X-ray equipment for diagnosis comes in different sizes and shapes depending on the scan type to perform. The X-ray spectrum is the energy distribution of the beam photons and consists of a continuous spectrum of photons braking and discrete spectrum due to the characteristic photons. The knowledge of the X-rays spectrum is important to understand like they affect the voltage changes (k Vp), current (m A), time (s) and the type of filter in the interaction mechanisms between X-rays and patient's body, the image receptor or other material that gets in the beam. Across the spectrum can be estimated the absorbed dose in any point of the patient, the quality of the image and the scattered radiation (which is related to the dose received by the equipment operator). The Monte Carlo method was used by MCNP5 code to calculate the spectrum of X-rays that occurs when a monoenergetic electron beam of 250 keV interact with targets of Mo, Rh and W. The spectra were calculated with and without filter, and the values of ambient dose equivalent were estimated, as well as the air kerma. (Author)

  18. Aspergillosis - chest x-ray (image)

    Science.gov (United States)

    ... usually occurs in immunocompromised individuals. Here, a chest x-ray shows that the fungus has invaded the lung ... are usually seen as black areas on an x-ray. The cloudiness on the left side of this ...

  19. Soft x-ray Planetary Imager

    Data.gov (United States)

    National Aeronautics and Space Administration — The project is to prototype a soft X-ray Imager for planetary applications that has the sensitivity to observe solar system sources of soft  X-ray emission. A strong...

  20. Stabilized x-ray generator power supply

    International Nuclear Information System (INIS)

    Saha, Subimal; Purushotham, K.V.; Bose, S.K.

    1986-01-01

    X-ray diffraction and X-ray fluorescence analysis are very much adopted in laboratories to determine the type and structure of the constituent compounds in solid materials, chemical composition of materials, stress developed on metals etc. These experiments need X-ray beam of fixed intensity and wave length. This can only be achieved by X-ray generator having highly stabilized tube voltage and tube current. This paper describes how X-ray tube high voltage and electron beam current are stabilized. This paper also highlights generation of X-rays, diffractometry and X-ray fluorescence analysis and their wide applications. Principle of operation for stabilizing the X-ray tube voltage and current, different protection circuits adopted, special features of the mains H.V. transformer and H.T. tank are described in this report. (author)

  1. X-ray electromagnetic application technology

    International Nuclear Information System (INIS)

    2011-01-01

    The investigating committee aimed at research on electromagnetic fields in functional devices and X-ray fibers for efficient coherent X-ray generation and their material science, high-precision manufacturing, particularly for X-ray electromagnetic application technology from January 2006 to December 2008. In this report, we describe our research results, in particular, on the topics of synchrotron radiation and free-electron laser, Saga Synchrotron Project, X-ray waveguides and waveguide-based lens-less hard-X-ray imaging, X-ray nanofocusing for capillaries and zone plates, dispersion characteristics in photonics crystal consisting of periodic atoms for nanometer waveguides, electromagnetic characteristics of grid structures for scattering fields of nano-meter electromagnetic waves and X-rays, FDTD parallel computing of fundamental scattering and attenuation characteristics of X-ray for medical imaging diagnosis, orthogonal relations of electromagnetic fields including evanescent field in dispersive medium. (author)

  2. Development of quantitative x-ray microtomography

    International Nuclear Information System (INIS)

    Deckman, H.W.; Dunsmuir, J.A.; D'Amico, K.L.; Ferguson, S.R.; Flannery, B.P.

    1990-01-01

    The authors have developed several x-ray microtomography systems which function as quantitative three dimensional x-ray microscopes. In this paper the authors describe the evolutionary path followed from making the first high resolution experimental microscopes to later generations which can be routinely used for investigating materials. Developing the instrumentation for reliable quantitative x-ray microscopy using synchrotron and laboratory based x-ray sources has led to other imaging modalities for obtaining temporal and spatial two dimensional information

  3. X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Raman, S.; Sparks, C.J. Jr.

    1978-01-01

    An experimental set-up for x-ray fluorescence analysis with synchrotron radiation was built and installed at the Stanford Synchrotron Radiation Project. X-ray spectra were taken from numerous and varied samples in order to assess the potential of synchrotron radiation as an excitation source for multielement x-ray fluorescence analysis. For many applications, the synchrotron radiation technique is shown to be superior to other x-ray fluorescence methods, especially those employing electrons and protons as excitation sources

  4. Phase-sensitive X-ray imager

    Science.gov (United States)

    Baker, Kevin Louis

    2013-01-08

    X-ray phase sensitive wave-front sensor techniques are detailed that are capable of measuring the entire two-dimensional x-ray electric field, both the amplitude and phase, with a single measurement. These Hartmann sensing and 2-D Shear interferometry wave-front sensors do not require a temporally coherent source and are therefore compatible with x-ray tubes and also with laser-produced or x-pinch x-ray sources.

  5. Element specific X-ray fluorescene microtomography

    OpenAIRE

    Günzler, Til Florian

    2003-01-01

    X-ray fluorescence is widely known as an element-specific scanning analytic tool. It is used in many fields of science and technology and has given major new insights into different problems. The relatively large penetration depth of x rays into matter makes them ideally suited for tomography. The combination of x-ray fluorescence analysis and scanning microtomography, hereafter called x-ray fluorescence microtomography, has been further developed and improved in this work. Employing the newl...

  6. X-ray diagnostics - benefits and risks

    International Nuclear Information System (INIS)

    Bartholomaeus, Melanie

    2016-01-01

    The brochure on benefits and risks of X-ray diagnostics discusses the following issues: X radiation - a pioneering discovery and medical sensation, fundamentals of X radiation, frequency of X-ray examinations in Germany in relation to CT imaging, radiation doses resulting from X-ray diagnostics, benefits of X-ray diagnostics - indication and examples, risks - measures for radiation exposure reductions, avoidance of unnecessary examinations.

  7. Shift focal spot X-ray tube to the imposition anode under long exposure

    Science.gov (United States)

    Obodovskiy, A. V.; Bessonov, V. B.; Larionov, I. A.

    2018-02-01

    X-ray non-destructive testing is an integral part of any modern industrial production. Microfocus X-ray sources make it possible to obtain projected images with an increased spatial resolution by using a direct geometric magnification during the survey. On the basis of the St. Petersburg State Electrotechnical University staff of the department of electronic devices and equipment has been designed model of microfocus X-ray computed tomography.

  8. X-ray microprobe - A new facility for cell irradiations in Krakow

    Energy Technology Data Exchange (ETDEWEB)

    Bozek, S. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland); Jagiellonian University Medical College, ul. Medyczna 9, 30-688 Krakow (Poland); Bielecki, J. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland); Baszak, J. [Hamamatsu Photonics GmbH, Polish Office (Poland)], E-mail: jbaszak@hamamatsu.de; Doruch, H.; Hajduk, R.; Lekki, J. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland); Stachura, Z. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland)], E-mail: Zbigniew.Stachura@ifj.edu.pl; Kwiatek, W.M. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland)

    2009-06-15

    A new, multi-purpose X-ray microprobe has been constructed in Krakow. The Hamamatsu L9191 microfocusing X-ray tube is used as a source of radiation. The microprobe is equipped with three dedicated experimental lines serving for the computed microtomography (CMT), for micro-XRF or TXRF measurements (micro-X-ray induced Fluorescence, Total reflexion XRF) and for mammalian cell irradiations. Details of the construction of the experimental line dedicated to irradiations are presented.

  9. High-speed radiography and x-ray cinematography by high-current betatrons

    International Nuclear Information System (INIS)

    Akimochkin, Yu.V.; Akulov, G.V.; Leunov, F.G.; Moskalev, V.A.; Ryabukhin, V.L.

    1979-01-01

    The paper provides a description of an equipment system comprising a pair of 25 MeV high-current betatrons and an X-ray drum-type cinecamera for high-speed radiography and X-ray cinematography for use when studying dynamics of objects moving at a rate of 0.5 - 3.0 km/s as well as in X-ray cinematography of processes at a rate of up to 1 m/s. (author)

  10. A compact high vacuum heating chamber for in-situ x-ray scattering studies.

    Science.gov (United States)

    Bertram, F; Deiter, C; Pflaum, K; Seeck, O H

    2012-08-01

    A very compact multi purpose high vacuum heating chamber for x-ray scattering techniques was developed. The compact design allows the chamber to be installed on high precision diffractometers which usually cannot support heavy and/or large equipment. The chamber is covered by a Be dome allowing full access to the hemisphere above the sample which is required for in-plane grazing incident x-ray diffraction and out-off plane wide angle x-ray diffraction.

  11. A compact high vacuum heating chamber for in-situ x-ray scattering studies

    Energy Technology Data Exchange (ETDEWEB)

    Bertram, F.; Deiter, C.; Pflaum, K.; Seeck, O. H. [Hamburger Synchrotronstrahlungslabor am Deutschen Elektronen-Synchrotron, Notkestr. 85, 22607 Hamburg (Germany)

    2012-08-15

    A very compact multi purpose high vacuum heating chamber for x-ray scattering techniques was developed. The compact design allows the chamber to be installed on high precision diffractometers which usually cannot support heavy and/or large equipment. The chamber is covered by a Be dome allowing full access to the hemisphere above the sample which is required for in-plane grazing incident x-ray diffraction and out-off plane wide angle x-ray diffraction.

  12. Code of safe practice for the use of x-rays in dentistry

    International Nuclear Information System (INIS)

    1991-06-01

    The purpose of this Code of Safe Practice for the Use of X-rays in Dentistry is to provide criteria for working procedures, x-ray equipment and protective materials necessary for the use of x-rays in dental diagnosis according to currently accepted standards of safety. Conformity with this code may be taken as a primary indication of compliance with radiation protection legislation. 7 refs., 1 ill

  13. Practical X-ray diagnostics orthopedics and trauma surgery. Indication, adjustment technique and radiation protection

    International Nuclear Information System (INIS)

    Flechtenmacher, Johannes; Sabo, Desiderius

    2014-01-01

    The book on X-ray diagnostics in orthopedics and trauma surgery includes the following chapters: 1. Introduction: radiation protection, equipment technology radiological diagnostics of skeleton carcinomas, specific aspects of trauma surgery, special aspects of skeleton radiology for children. 2. X-ray diagnostics of different anatomical regions: ankle joint, knee, hips and pelvis, hand and wrist joint, elbow, shoulder, spinal cord. 3. Appendix: radiation protection according to the X-ray regulations.

  14. Radiation dosimetry of computed tomography x-ray scanners

    International Nuclear Information System (INIS)

    Poletti, J.L.; Williamson, B.D.P.; Le Heron, J.C.

    1983-01-01

    This report describes the development and application of the methods employed in National Radiation Laboratory (NRL) surveys of computed tomography x-ray scanners (CT scanners). It includes descriptions of the phantoms and equipment used, discussion of the various dose parameters measured, the principles of the various dosimetry systems employed and some indication of the doses to occupationally exposed personnel

  15. Radiation safety in X-ray diagnostic installations

    International Nuclear Information System (INIS)

    Das, K.R.; Ambiger, T.Y.; Viswanathan, P.S.

    1977-01-01

    Safety measures to be strictly adhered to in handling X-ray equipment and exposing patients to X-radiation are described in detail. Hazards resulting from ignorance and careless handling are mentioned. Methods of shielding are indicated. (A.K.)

  16. Guide to request license for industrial X-rays practices

    International Nuclear Information System (INIS)

    2000-05-01

    In this work the instructions it plows described to request license for practices it of industrial x-ray it continued. The instructions but important: they plows license type, purpose of the application, source and equipment, location of local the, program of radiological protection and security

  17. The Beginnings of X-ray Crystallography

    Indian Academy of Sciences (India)

    IAS Admin

    The Beginnings of X-ray Crystallography. A Profile on the Two Braggs. Those were the days when Science was hovering around the wave–particle duality. William. Henry Bragg was toying with the idea that X-rays are particles and the observation made by Max von Laue that X-rays are diffracted by crystals could indeed ...

  18. Center for X-ray Optics, 1988

    Energy Technology Data Exchange (ETDEWEB)

    1989-04-01

    This report briefly reviews the following topics: soft-x-ray imaging; reflective optics for hard x-rays; coherent XUV sources; spectroscopy with x-rays; detectors for coronary artery imaging; synchrotron-radiation optics; and support for the advanced light source.

  19. X-Ray Exam: Femur (Upper Leg)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Femur (Upper Leg) KidsHealth / For Parents / X- ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  20. X-Rays, Pregnancy and You

    Science.gov (United States)

    ... Emitting Products and Procedures Medical Imaging Medical X-ray Imaging X-Rays, Pregnancy and You Share Tweet Linkedin Pin it ... the decision with your doctor. What Kind of X-Rays Can Affect the Unborn Child? During most x- ...

  1. X-Ray Exam: Scoliosis (For Parents)

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Scoliosis KidsHealth / For Parents / X-Ray Exam: Scoliosis What's in this article? What It Is Why ... You Have Questions Print What It Is A scoliosis X-ray is a relatively safe and painless ...

  2. Cryotomography x-ray microscopy state

    Science.gov (United States)

    Le Gros, Mark; Larabell, Carolyn A.

    2010-10-26

    An x-ray microscope stage enables alignment of a sample about a rotation axis to enable three dimensional tomographic imaging of the sample using an x-ray microscope. A heat exchanger assembly provides cooled gas to a sample during x-ray microscopic imaging.

  3. Student X-Ray Fluorescence Experiments

    Science.gov (United States)

    Fetzer, Homer D.; And Others

    1975-01-01

    Describes the experimental arrangement for x-ray analysis of samples which involves the following: the radioisotopic x-ray disk source; a student-built fluorescence chamber; the energy dispersive x-ray detector, linear amplifier and bias supply; and a multichannel pulse height analyzer. (GS)

  4. Electron beam parallel X-ray generator

    Science.gov (United States)

    Payne, P.

    1967-01-01

    Broad X ray source produces a highly collimated beam of low energy X rays - a beam with 2 to 5 arc minutes of divergence at energies between 1 and 6 keV in less than 5 feet. The X ray beam is generated by electron bombardment of a target from a large area electron gun.

  5. Total reflection x-ray fluorescence (TXRF)

    International Nuclear Information System (INIS)

    Hockett, R.S.

    1995-01-01

    Total reflection X-Ray Fluorescence (TXRF) is a glancing x-ray analytical technique which is used primarily to measure surface metal contamination on semiconductor substrates. This is a review of Total reflection X-Ray Fluorescence (TXRF) applications for silicon semiconductor processing. In addition, some comments are made about the future of TXRF, and in particular, synchrotron radiation TXRF (SR-TXRF)

  6. Automatic weld joint X-ray inspection

    International Nuclear Information System (INIS)

    Richter, H.U.; Linke, D.; Siems, K.D.; Kruse, H.; Schuetze, E.

    1990-01-01

    A gantry mounted robotic x-ray inspection unit has been developed for the series testing of small and medium sized welded components (pipe bends and nozzles). The unit features computer controlled positioning of the x-ray tube and x-ray image amplifier. Image quality classes 2 and even 1 could be achieved without difficulty. (author)

  7. Pulsating X-ray sources

    International Nuclear Information System (INIS)

    Trumper, J.

    1986-01-01

    The discovery of pulsating X-ray sources in close binary systems was one of the major achievements of the Uhuru satellite. Today one knows about two dozens of these sources with pulsational periods between 69 ms and 835 s. In most cases the X-ray source orbits an early-type star of high mass having a rather large optical luminosity. There are a few exceptions: GX1+4 is associated with a late-type (M6) giant, 4U1616-67 has a comparison of very low mass (≤ 0.1 M/sub sub solar/), and Her X-1 is a borderline case, since its counterpart HZ Her is an A-F star of -- 2/sub sub solar/. It is clear that the X-ray sources in these systems are rotating magnetized neutron stars accreting from their normal companion, probably in most cases via Roche lobe overflow which leads to the formation of an accretion disk. In some cases (e.g. Vela X-1) the accretion proceeds via a stellar wind. Pulsations occur because in the immediate vicinity of the neutron star the matter is funneled by the strong magnetic field onto the polar caps where a hot and very luminous plasma is formed. Typical luminosities are huge, namely of the order of 10/sup 37/ erg/s which are radiated at effective temperatures of -- 10/sup 8/ K. Much has been learned about these systems and about neutron stars from studies of pulse arrival times and source spectra. The author briefly summarizes some of the major results and discusses some very recent results obtained with EXOSAT

  8. The Kharkov X-ray Generator Facility NESTOR

    OpenAIRE

    Shcherbakov , A.A.; Androsov , V.P.; Aizatsky , N.; Boriskin , V.N.; Bulyak , E.V.; Dovbnya , A.N.; Gladkikh , P.; Gordienko , A.N.; Grevtsev , V.A.; Gvozd , A.; Ivashchenko , V.E.; Kalamayko , A.A.; Karnaukhov , I.I.; Karnaukhov , I.M.; Kozin , V.P.

    2013-01-01

    WEPWA060 - ISBN 978-3-95450-122-9; International audience; The last few years the sources of the X-rays NESTOR based on a storage ring with low beam energy and Compton scattering of intense laser beam are under design and development in NSC KIPT. The main task of the project is to develop compact intense X-ray generator on the base of relatively cheap accelerator equipment and up-to-date laser technologies. The paper is devoted to description of the last results on construction and commission...

  9. X-ray technique and technology development trends

    International Nuclear Information System (INIS)

    Vlasov, P.V.; Chikirdin, Eh.G.

    1994-01-01

    Application of new types of x-ray devices for diagnosis of diseases was described. Modern roentgenological devices (Rentgen-60) were supplied by remote handling unit with the help of roentgen television. Roentgen television is based on transmission of image from the output of the screen of amplifier of x-ray image on the input of transmitting television camera. Scanning of input image accurred inside the camera, analog videosignal was amplified and reproduced on the display. The prospects of development of such roentgen equipment was emphasized

  10. Evaluation device of diagnostic X-ray beam

    International Nuclear Information System (INIS)

    Pela, Carlos Alberto; Paula, Eldereis de; Bruco, Jose Luiz; Ghilardi Netto, Thomaz

    1996-01-01

    A device developed to determine the physical parameters useful to the evaluation of both dental and medical X-ray equipment is presented. Nine detectors connected each one to a signal amplifier are used. The amplifiers output has being connected to an analog to digital interface plugged in a PC-AT microcomputer. The X-ray pass through filters before reaching the detectors. The data collected by microcomputer are used to calculate the kVp and other factors as total tube filtration, waveform, half-value layer, exposure rate and exposure time

  11. Protonium X-ray spectroscopy

    CERN Document Server

    Gotta, D

    1999-01-01

    The Lyman and Balmer transitions from antiprotonic hydrogen and deuterium were studied extensively at the low-energy-antiproton ring LEAR at CERN in order to determine the strong interaction effects. A first series of experiments $9 was performed with semiconductor and gaseous X-ray detectors. In the last years of LEAR operation using a Bragg crystal spectrometer, strong interaction parameters in the 2p states of antiprotonic hydrogen and deuterium were measured $9 directly. The results of the measurements support the meson-exchange models describing the medium and long range part of the nucleon-antinucleon interaction. (39 refs).

  12. X-ray intensifying screens

    International Nuclear Information System (INIS)

    Bossomaier, T.R.J.; Sangway, P.C.

    1979-01-01

    It is claimed that stabilization of X-ray intensifying screens against discolouration and hydrolysis of lanthanum or gadolinium oxyhalide phosphors can be achieved by incorporating into the phosphor/binder formulation a compound containing free epoxy groups. Suitable epoxy compounds include gamma glycidoxy trimethoxy silane and dimethyl di(m-glycidoxy methylphenyl) methane. The oxyhalide may be activated by Tb, Tm or Yb and may be mixed with other phosphors. Plasticisers and organo-tin stabilisers for the formulation are given. Many binders are specified, preferably these should not react with the free epoxy groups. (UK)

  13. Method for spatially modulating X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2015-03-10

    A method and apparatus are provided for spatially modulating X-rays or X-ray pulses using microelectromechanical systems (MEMS) based X-ray optics. A torsionally-oscillating MEMS micromirror and a method of leveraging the grazing-angle reflection property are provided to modulate X-ray pulses with a high-degree of controllability.

  14. Picosecond x-ray streak camera studies

    International Nuclear Information System (INIS)

    Kasyanov, Yu.S.; Malyutin, A.A.; Richardson, M.C.; Chevokin, V.K.

    1975-01-01

    Some initial results of direct measurement of picosecond x-ray emission from laser-produced plasmas are presented. A PIM-UMI 93 image converter tube, incorporating an x-ray sensitive photocathode, linear deflection, and three stages of image amplification was used to analyse the x-ray radiation emanating from plasmas produced from solid Ti targets by single high-intensity picosecond laser pulses. From such plasmas, the x-ray emission typically persisted for times of 60psec. However, it is shown that this detection system should be capable of resolving x-ray phenomena of much shorter duration. (author)

  15. Si(Li) X-ray detector

    International Nuclear Information System (INIS)

    Yuan Xianglin; Li Zhiyong; Hong Xiuse

    1990-08-01

    The fabrication technology of the 10∼80 mm 2 Si(Li) X-ray detectors are described and some problems concerning technology and measurement are discussed. The specifications of the detectors are shown as well. The Si(Li) X-ray detector is a kind of low energy X-ray detectors. Owing to very high energy resolution, fine linearity and high detection efficiency in the range of low energy X-rays, it is widely used in the fields of nuclear physics, medicine, geology and environmental protection, etc,. It is also a kernel component for the scanning electron microscope and X-ray fluorescence analysis systems

  16. NIKOLA TESLA AND THE X-RAY

    OpenAIRE

    Rade R. Babic

    2005-01-01

    After professor Wilhelm Konrad Röntgen published his study of an x-ray discovery (Academy Bulletin, Berlin, 08. 11. 1895.), Nikola Tesla published his first study of an x-ray on the 11th of March in 1896. (X-ray, Electrical Review). Until the 11th of August in 1897 he had published ten studies on this subject. All Tesla,s x-ray studies were experimental, which is specific to his work. Studying the nature of the x-ray, he established a new medical branch-radiology. He wrote:” There’s no doubt...

  17. Miniature x-ray point source for alignment and calibration of x-ray optics

    International Nuclear Information System (INIS)

    Price, R.H.; Boyle, M.J.; Glaros, S.S.

    1977-01-01

    A miniature x-ray point source of high brightness similar to that of Rovinsky, et al. is described. One version of the x-ray source is used to align the x-ray optics on the Argus and Shiva laser systems. A second version is used to determine the spatial and spectral transmission functions of the x-ray optics. The spatial and spectral characteristics of the x-ray emission from the x-ray point source are described. The physical constraints including size, intensity and thermal limitations, and useful lifetime are discussed. The alignment and calibration techniques for various x-ray optics and detector combinations are described

  18. X-ray and gamma radiography devices

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    When we are using this technique, we also must familiar with the device and instrument that used such as gamma projector, crawler, x-ray tubes and others. So this chapter discussed detailed on device used for radiography work. For the x-ray and gamma, their characteristics are same but the source to produce is a big different. X-ray produced from the machine meanwhile, gamma produce from the source such as Co-60 and IR-192. Both are electromagnetic waves. So, the reader can have some knowledge on what is x-ray tube, discrete x-ray and characteristic x-ray, how the machine works and how to control a machine, what is source for gamma emitter, how to handle the projector and lastly difference between x-ray and gamma. Of course this cannot be with the theory only, so detailed must be learned practically.

  19. X ray imaging microscope for cancer research

    Science.gov (United States)

    Hoover, Richard B.; Shealy, David L.; Brinkley, B. R.; Baker, Phillip C.; Barbee, Troy W., Jr.; Walker, Arthur B. C., Jr.

    1991-01-01

    The NASA technology employed during the Stanford MSFC LLNL Rocket X Ray Spectroheliograph flight established that doubly reflecting, normal incidence multilayer optics can be designed, fabricated, and used for high resolution x ray imaging of the Sun. Technology developed as part of the MSFC X Ray Microscope program, showed that high quality, high resolution multilayer x ray imaging microscopes are feasible. Using technology developed at Stanford University and at the DOE Lawrence Livermore National Laboratory (LLNL), Troy W. Barbee, Jr. has fabricated multilayer coatings with near theoretical reflectivities and perfect bandpass matching for a new rocket borne solar observatory, the Multi-Spectral Solar Telescope Array (MSSTA). Advanced Flow Polishing has provided multilayer mirror substrates with sub-angstrom (rms) smoothnesss for the astronomical x ray telescopes and x ray microscopes. The combination of these important technological advancements has paved the way for the development of a Water Window Imaging X Ray Microscope for cancer research.

  20. Development of an X-ray detector using photodiodes

    International Nuclear Information System (INIS)

    Gonzalez G, J.; Azorin V, J. C.; Sosa A, M. A.; Ceron, P.

    2016-10-01

    Currently the radiation detectors for medical applications are very high value in the market and are difficult to access as training material. In the Sciences and Engineering Division of the Guanajuato University (Mexico) investigations are carried out related to ionizing radiations, especially with X-rays. To overcome the lack of materials has had to resort to borrowing equipment from other institutions, so its use and availability are intermittent. For these reasons is proposed to design and implement an X-ray detector for the use of the work group and the University. This work aims to build an X-ray semiconductor detector using inexpensive and affordable materials, is also proposed the use of a photodiode sensor and an Arduino analog-digital card and a LCD display showing the data. (Author)

  1. The X-ray Telescope of the CAST Experiment

    CERN Document Server

    Kotthaus, Rainer; Friedrich, P.; Kang, D.; Hartmann, R.; Kuster, M.; Lutz, G.; Strüder, L.

    2005-01-01

    The CERN Axion Solar Telescope (CAST) searches for solar axions employing a 9 Tesla superconducting dipole magnet equipped with 3 independent detection systems for X-rays from axion-photon conversions inside the 10 m long magnetic field. Results of the first 6 months of data taking in 2003 imply a 95 % CL upper limit on the axion-photon coupling constant of 1.16x10(-10) GeV(-1) for axion masses < 0.02 eV. The most sensitive detector of CAST is a X-ray telescope consisting of a Wolter I type mirror system and a fully depleted pn-CCD as focal plane detector. Exploiting the full potential of background suppression by focussing X-rays emerging from the magnet bore, the axion sensitivity obtained with telescope data taken in 2004, for the first time in a controlled laboratory experiment, will supersede axion constraints derived from stellar energy loss arguments.

  2. X-ray radiography with highly charged ions

    Science.gov (United States)

    Marrs, Roscoe E.

    2000-01-01

    An extremely small (1-250 micron FWHM) beam of slow highly charged ions deexciting on an x-ray production target generates x-ray monochromatic radiation that is passed through a specimen and detected for imaging. The resolution of the x-ray radiograms is improved and such detection is achieved with relatively low dosages of radiation passing through the specimen. An apparatus containing an electron beam ion trap (and modifications thereof) equipped with a focusing column serves as a source of ions that generate radiation projected onto an image detector. Electronic and other detectors are able to detect an increased amount of radiation per pixel than achieved by previous methods and apparati.

  3. Theory of inelastic scattering and absorption of X-rays

    CERN Document Server

    Veenendaal, Michel van

    2015-01-01

    This comprehensive, self-contained guide to X-ray spectroscopy will equip you with everything you need to begin extracting the maximum amount of information available from X-ray spectra. Key topics such as the interaction between X-rays and matter, the basic theory of spectroscopy, and selection and sum rules, are introduced from the ground up, providing a solid theoretical grounding. The book also introduces core underlying concepts such as atomic structure, solid-state effects, the fundamentals of tensor algebra and group theory, many-body interactions, scattering theory, and response functions, placing spectroscopy within a broader conceptual framework, and encouraging a deep understanding of this essential theoretical background. Suitable for graduate students, researchers, materials scientists and optical engineers, this is the definitive guide to the theory behind this powerful and widely used technique.

  4. Installation of an automatic X-ray spectrachemical laboratory

    International Nuclear Information System (INIS)

    Villanova, R.A.; Sermin, D.F.

    Several steps necessary to install an X-ray spectrometer automation system for stcels and raw material analysis, are discussed. Equipment description, analytical programme, calibration, tests and other subjects regarding personnel training, technical assistance and maintenance, are included. A perfect adjustment of the choosen equipment, in so far as it cocerns the technical performance and operation costs, is also dotained. A condensed translation in English of the principals chapters is presented at the end of the work [pt

  5. Submicron X-ray diffraction

    International Nuclear Information System (INIS)

    MacDowell, Alastair; Celestre, Richard; Tamura, Nobumichi; Spolenak, Ralph; Valek, Bryan; Brown, Walter; Bravman, John; Padmore, Howard; Batterman, Boris; Patel, Jamshed

    2000-01-01

    At the Advanced Light Source in Berkeley the authors have instrumented a beam line that is devoted exclusively to x-ray micro diffraction problems. By micro diffraction they mean those classes of problems in Physics and Materials Science that require x-ray beam sizes in the sub-micron range. The instrument is for instance, capable of probing a sub-micron size volume inside micron sized aluminum metal grains buried under a silicon dioxide insulating layer. The resulting Laue pattern is collected on a large area CCD detector and automatically indexed to yield the grain orientation and deviatoric (distortional) strain tensor of this sub-micron volume. A four-crystal monochromator is then inserted into the beam, which allows monochromatic light to illuminate the same part of the sample. Measurement of diffracted photon energy allows for the determination of d spacings. The combination of white and monochromatic beam measurements allow for the determination of the total strain/stress tensor (6 components) inside each sub-micron sized illuminated volume of the sample

  6. Standardized method for reproducing the sequential X-rays flap

    International Nuclear Information System (INIS)

    Brenes, Alejandra; Molina, Katherine; Gudino, Sylvia

    2009-01-01

    A method is validated to estandardize in the taking, developing and analysis of bite-wing radiographs taken in sequential way, in order to compare and evaluate detectable changes in the evolution of the interproximal lesions through time. A radiographic positioner called XCP® is modified by means of a rigid acrylic guide, to achieve proper of the X ray equipment core positioning relative to the XCP® ring and the reorientation during the sequential x-rays process. 16 subjects of 4 to 40 years old are studied for a total number of 32 registries. Two x-rays of the same block of teeth of each subject have been taken in sequential way, with a minimal difference of 30 minutes between each one, before the placement of radiographic attachment. The images have been digitized with a Super Cam® scanner and imported to a software. The measurements in X and Y-axis for both x-rays were performed to proceed to compare. The intraclass correlation index (ICI) has shown that the proposed method is statistically related to measurement (mm) obtained in the X and Y-axis for both sequential series of x-rays (p=0.01). The measures of central tendency and dispersion have shown that the usual occurrence is indifferent between the two measurements (Mode 0.000 and S = 0083 and 0.109) and that the probability of occurrence of different values is lower than expected. (author) [es

  7. Portable X-ray reflectometer using a low power polychromatic X-ray tube

    International Nuclear Information System (INIS)

    Ohnishi, Tsunemasa; Imashuku, Susumu; Yuge, Koretaka; Kawai, Jun; Shimura, Naomi

    2014-01-01

    We developed a portable X-ray reflectometer which measures energy dispersive X-ray reflectivity using a polychromatic X-rays from a low power (a few watts) X-ray tube and a silicon drift detector. A thin Cu film on silicon substrate using the portable reflectometer was measured. A fringe pattern was shifted due to the change of the X-ray incident angle. The measured peak position of the fringe pattern was satisfactorily agreed with the calculation. (author)

  8. Full-field transmission x-ray imaging with confocal polycapillary x-ray optics

    OpenAIRE

    Sun, Tianxi; MacDonald, C. A.

    2013-01-01

    A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for histology specimens.

  9. Practical methods used in the system of controlling of x-ray apparatus

    International Nuclear Information System (INIS)

    Ogrodowczyk, A.; Lapinski, K.; Jankowski, J.; Staniszewska, M.A.

    1993-01-01

    An x-ray apparatus like any other device becomes worn out. In order to avoid x-ray examinations of patients performed using a worn out apparatus a periodical control of such appliances should be carried out. This work presents a methodology based on simple quality tests for a standard x-ray apparatus. These tests measure parameters of x-ray tubes and beams of radiation. A positive feature of these tests is that they replace very expensive specialistic measuring equipment. (author). 14 refs, 2 tabs, 3 figs

  10. The beginning of studies and use of X-rays in the Czech Lands

    International Nuclear Information System (INIS)

    Tesinska, E.; Hlava, A.; Zackova, H.

    1995-01-01

    Based on historical sources this paper to present the remarkably early response to Roentgen's discovery of X-rays in the Czech Lands, then part of the Austro-Hungarian Monarchy, and to call attention to some early radiological studies done here before the foundation of Czechoslovakia in 1918. The early X-ray experiments by physicists and engineers, the first attempts at X-ray diagnostics and therapy, and the early X-ray equipments of provincial hospitals and practitioners surgeries are reviewed. (J.K.) 6 refs

  11. Licensing of non intrusive inspection equipment s for load and passengers vehicles that use X rays with energies up to 9 MeV. Mexican experience; Licenciamiento de equipos de inspeccion no intrusiva para vehiculos de carga y pasajeros que utilizan rayos X con energias de hasta 9 megaelectronvolts. Experiencia Mexicana

    Energy Technology Data Exchange (ETDEWEB)

    Munoz M, G. A.; Jimenez C, I., E-mail: armando.munoz@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Jose Ma. Barragan 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2013-10-15

    In the last years and like part of the extensive program of national security, in Mexico have been introduced a great quantity of non intrusive inspection equipment s for load and passengers vehicles that use X rays up to 9 MeV. Due to the great variety of equipment s, the Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexican regulator organ) has established specific guidelines for their licensing and use supervision. In this work the adopted guidelines are exposed in the technical and administrative evaluation for the later licensing of these equipment s. Relative particular questions to the site of these equipment s and the impact in the public opinion that their use can generate are discussed. (author)

  12. X-ray scan detection for cargo integrity

    Science.gov (United States)

    Valencia, Juan; Miller, Steve

    2011-04-01

    The increase of terrorism and its global impact has made the determination of the contents of cargo containers a necessity. Existing technology allows non-intrusive inspections to determine the contents of a container rapidly and accurately. However, some cargo shipments are exempt from such inspections. Hence, there is a need for a technology that enables rapid and accurate means of detecting whether such containers were non-intrusively inspected. Non-intrusive inspections are most commonly performed utilizing high powered X-ray equipment. The challenge is creating a device that can detect short duration X-ray scans while maintaining a portable, battery powered, low cost, and easy to use platform. The Pacific Northwest National Laboratory (PNNL) has developed a methodology and prototype device focused on this challenge. The prototype, developed by PNNL, is a battery powered electronic device that continuously measures its X-ray and Gamma exposure, calculates the dose equivalent rate, and makes a determination of whether the device has been exposed to the amount of radiation experienced during an X-ray inspection. Once an inspection is detected, the device will record a timestamp of the event and relay the information to authorized personnel via a visual alert, USB connection, and/or wireless communication. The results of this research demonstrate that PNNL's prototype device can be effective at determining whether a container was scanned by X-ray equipment typically used for cargo container inspections. This paper focuses on laboratory measurements and test results acquired with the PNNL prototype device using several X-ray radiation levels.

  13. X-ray monitoring for astrophysical applications on Cubesat

    Science.gov (United States)

    Pina, L.; Hudec, R.; Inneman, A.; Cerna, D.; Jakubek, J.; Sieger, L.; Dániel, V.; Cash, W.; Mikulickova, L.; Pavlica, R.; Belas, E.; Polak, J.

    2015-05-01

    The primary objective of the project VZLUSAT-1 is the development, manufacturing, qualification and experimental verification of products and technologies in Earth orbit (IOD - In-Orbit Demonstration). This work addresses the issue of X-ray monitoring for astrophysical applications. The proposed wide-field optical system has not been used in space yet. The proposed novel approach is based on the use of 1D "Lobster eye" optics in combination with Timepix X-ray detector in the energy range 3 - 40 keV. The proposed project includes theoretical study and a functional sample of the Timepix X-ray detector with multifoil wide-field X-ray "Lobster eye" optics. Using optics to focus X-rays on a detector is the only solution in cases the intensity of impinging X-ray radiation is below the sensitivity of the detector, e.g. while monitoring astrophysical objects in space, or phenomena in the Earth's atmosphere. On board the functions and features of Radiation Hardened Composite Housing (RHCH), Solar panels based on composite substrate and Hollow Retro Reflector Array based on composite (HRRA) will be verified. To verify the properties of the developed products the satellite is equipped by Health Monitoring system (HM). HM system includes temperature, volatiles, radiation and mechanical properties sensors. The custom ADCS algorithms are being developed within the project. Given the number of IOD experiments and the necessary power the 1U CubeSat is equipped with Composite Deployable Panels (CDP) where HM panels and additional Solar panels are located. Satellite platform is assembled from commercial parts. Mission VZLUSAT-1 is planned for 6 months with launch in 2016.

  14. Facility for testing and certification of medical x-ray films at BARC

    International Nuclear Information System (INIS)

    Sharma, Reena; Jayalakshmi, V.; Nair, C.P.R.

    2006-12-01

    The major problem faced in the x-ray department with regard to x-ray films is the non consistent image quality of x-ray films leading to lesions missed/ wrong diagnosis and as a result retakes of the examination and increased radiation dosage to the patient. This report illustrates the methodology adopted by this Division towards implementation of quality assurance of the basic imaging devices namely the medical x-ray films. The characteristics properties desirable in x-ray films are the qualitative response of the emulsion to standard set of exposure and processing conditions in terms of speed, contrast and density. It should be consistent for exposure conditions in a custom built equipment simulating the quantum and type of energy that would be received by the film during diagnostic examinations. The phantom, geometrical set up and beam quality specifications as per the ISO standards required for x-ray sensitometry have been described in this report. (author)

  15. Anomalous X-Ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Wendin, G.

    1979-01-01

    The availability of tunable synchrotron radiation has made it possible systematically to perform x-ray diffraction studies in regions of anomalous scattering near absorption edges, e.g., in order to derive phase information for crystal structure determination. An overview is given of recent experimental and theoretical work and discussion of the properties of the anomalous atomic scattering factor, with emphasis on threshold resonances and damping effects. The results are applied to a discussion of the very strong anomalous dispersion recently observed near the L3 edge in a cesium complex. Also given is an overview of elements and levels where similar behavior can be expected. Finally, the influence of solid state and chemical effects on the absorption edge structure is discussed. 64 references.

  16. Anomalous x-ray scattering

    International Nuclear Information System (INIS)

    Wendin, G.

    1979-01-01

    The availability of tunable synchrotron radiation has made it possible systematically to perform x-ray diffraction studies in regions of anomalous scattering near absorption edges, e.g. in order to derive phase information for crystal structure determination. An overview is given of recent experimental and theoretical work and discuss the properties of the anomalous atomic scattering factor, with emphasis on threshold resonances and damping effects. The results are applied to a discussion of the very strong anomalous dispersion recently observed near the L 3 edge in a cesium complex. Also given is an overview of elements and levels where similar behavior can be expected. Finally, the influence of solid state and chemical effects on the absorption edge structure is discussed. 64 references

  17. Diffractive X-Ray Telescopes

    International Nuclear Information System (INIS)

    Skinner, G.K.; Skinner, G.K

    2010-01-01

    Diffractive X-ray telescopes using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution several orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro arc seconds or even better, that would allow, for example, imaging of the distorted spacetime in the immediate vicinity of the supermassive black holes in the center of active galaxies What then is precluding their immediate adoption Extremely long focal lengths, very limited bandwidth, and difficulty stabilizing the image are the main problems. The history and status of the development of such lenses is reviewed here and the prospects for managing the challenges that they present are discussed atmospheric absorption

  18. Quality assurance in X-ray diagnostic radiology - Report II

    International Nuclear Information System (INIS)

    Fosmark, H.; Rozycki, Z.

    1987-01-01

    In the context of an analysis of technical quality assurance in Norwegian X-ray departments, a survey has been carried out in 21 laboratories in 4 hospitals. The tests were restricted to equipment used in general radiography, and the parameters analysed were of kV (using an electronic penetrameter), exposure time, waveform, output and automatic exposure control systems. In addition, a trial to compare overall performance in radiography and fluoroscopy was performed with a PMMP test phantom (SPRI). The survey is presented in two reports. The first one covers details of procedures and equipment. In this second report results are given and discussed. The results show that most of the equipment does function satifactorily, but also demonstrate the need to introduce quality assurance in X-ray departments

  19. Sensors for x-ray astronomy satellite

    International Nuclear Information System (INIS)

    Makino, Fumiyoshi; Kondo, Ichiro; Nishioka, Yonero; Kameda, Yoshihiko; Kubo, Masaki.

    1980-01-01

    For the purpose of observing the cosmic X-ray, the cosmic X-ray astronomy satellite (CORSA-b, named ''Hakucho'', Japanese for cygnus,) was launched Feb. 21, 1979 by Institute of Space and Aeronautical Science, University of Tokyo. The primary objectives of the satellite are: to perform panoramic survey of the space for X-ray bursts and to perform the spectral and temporal measurement of X-ray sources. The very soft X-ray sensor for X-ray observation and the horizon sensor for spacecraft attitude sensing were developed by Toshiba Corporation under technical support by University of Tokyo and Nagoya University for ''Hakucho''. The features of these sensors are outlined in this paper. (author)

  20. Handbook of X-Ray Data

    CERN Document Server

    Zschornack, Günter

    2007-01-01

    This sourcebook is intended as an X-ray data reference for scientists and engineers working in the field of energy or wavelength dispersive X-ray spectrometry and related fields of basic and applied research, technology, or process and quality controlling. In a concise and informative manner, the most important data connected with the emission of characteristic X-ray lines are tabulated for all elements up to Z = 95 (Americium). This includes X-ray energies, emission rates and widths as well as level characteristics such as binding energies, fluorescence yields, level widths and absorption edges. The tabulated data are characterized and, in most cases, evaluated. Furthermore, all important processes and phenomena connected with the production, emission and detection of characteristic X-rays are discussed. This reference book addresses all researchers and practitioners working with X-ray radiation and fills a gap in the available literature.

  1. X-ray conditions and response characteristics of automatic dose control in cinematography

    International Nuclear Information System (INIS)

    Arai, Hiroaki

    1997-01-01

    X-ray characteristics including subject thickness (copper plate), tube voltage, tube current and irradiation time were measured at stability, with an automatic dose control x-ray generator for cineangiography. Regardless of subject thickness, it is possible that the energy input to the x-ray tube in one frame may be decreased. The automatic control response was measured after rapid fluctuation in subject thickness. Two inverter-type x-ray generators with different automatic control units were studied. The older control unit changes exposure dose by tube voltage and tube current, while the newer one changes exposure dose by tube voltage, tube current and irradiation time. The maximum rate of change in tube voltage is greater with the newer control unit. In addition, the actual tube current response of the newer control unit in increasing nominal value is faster than the older one. In the new control unit, for each pulse, irradiation is cut off by means of a signal that the exposure has reached the proper value. Thus given the same differential in subject thickness, the newer control unit resumed stability faster than the older one. (author)

  2. Laser induced x-ray `RADAR' particle physics model

    Science.gov (United States)

    Lockley, D.; Deas, R.; Moss, R.; Wilson, L. A.; Rusby, D.; Neely, D.

    2016-05-01

    The technique of high-power laser-induced plasma acceleration can be used to generate a variety of diverse effects including the emission of X-rays, electrons, neutrons, protons and radio-frequency radiation. A compact variable source of this nature could support a wide range of potential applications including single-sided through-barrier imaging, cargo and vehicle screening, infrastructure inspection, oncology and structural failure analysis. This paper presents a verified particle physics simulation which replicates recent results from experiments conducted at the Central Laser Facility at Rutherford Appleton Laboratory (RAL), Didcot, UK. The RAL experiment demonstrated the generation of backscattered X-rays from test objects via the bremsstrahlung of an incident electron beam, the electron beam itself being produced by Laser Wakefield Acceleration. A key initial objective of the computer simulation was to inform the experimental planning phase on the predicted magnitude of the backscattered X-rays likely from the test objects. This objective was achieved and the computer simulation was used to show the viability of the proposed concept (Laser-induced X-ray `RADAR'). At the more advanced stages of the experimental planning phase, the simulation was used to gain critical knowledge of where it would be technically feasible to locate key diagnostic equipment within the experiment. The experiment successfully demonstrated the concept of X-ray `RADAR' imaging, achieved by using the accurate timing information of the backscattered X-rays relative to the ultra-short laser pulse used to generate the electron beam. By using fast response X-ray detectors it was possible to derive range information for the test objects being scanned. An X-ray radar `image' (equivalent to a RADAR B-scan slice) was produced by combining individual X-ray temporal profiles collected at different points along a horizontal distance line scan. The same image formation process was used to generate

  3. The Livermore X-ray Laser Program

    International Nuclear Information System (INIS)

    Matthews, D.L.

    1992-01-01

    I will report on the status of x-ray laser development and its applications at Livermore. I will review some of our recent results and comment on where our future research is headed including plans for developing a compact x-ray laser users facility. Finally, I will briefly summarize the results of an X-ray Laser Applications Workshop that was held in San Francisco in January 1992

  4. X-ray data booklet. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. (ed.)

    1986-04-01

    A compilation of data is presented. Included are properties of the elements, electron binding energies, characteristic x-ray energies, fluorescence yields for K and L shells, Auger energies, energy levels for hydrogen-, helium-, and neonlike ions, scattering factors and mass absorption coefficients, and transmission bands of selected filters. Also included are selected reprints on scattering processes, x-ray sources, optics, x-ray detectors, and synchrotron radiation facilities. (WRF)

  5. Soft x-ray streak cameras

    International Nuclear Information System (INIS)

    Stradling, G.L.

    1988-01-01

    This paper is a discussion of the development and of the current state of the art in picosecond soft x-ray streak camera technology. Accomplishments from a number of institutions are discussed. X-ray streak cameras vary from standard visible streak camera designs in the use of an x-ray transmitting window and an x-ray sensitive photocathode. The spectral sensitivity range of these instruments includes portions of the near UV and extends from the subkilovolt x- ray region to several tens of kilovolts. Attendant challenges encountered in the design and use of x-ray streak cameras include the accommodation of high-voltage and vacuum requirements, as well as manipulation of a photocathode structure which is often fragile. The x-ray transmitting window is generally too fragile to withstand atmospheric pressure, necessitating active vacuum pumping and a vacuum line of sight to the x-ray signal source. Because of the difficulty of manipulating x-ray beams with conventional optics, as is done with visible light, the size of the photocathode sensing area, access to the front of the tube, the ability to insert the streak tube into a vacuum chamber and the capability to trigger the sweep with very short internal delay times are issues uniquely relevant to x-ray streak camera use. The physics of electron imaging may place more stringent limitations on the temporal and spatial resolution obtainable with x-ray photocathodes than with the visible counterpart. Other issues which are common to the entire streak camera community also concern the x-ray streak camera users and manufacturers

  6. Applications of soft x-ray lasers

    International Nuclear Information System (INIS)

    Skinner, C.H.

    1993-01-01

    The high brightness and short pulse duration of soft x-ray lasers provide unique advantages for novel applications. Imaging of biological specimens using x-ray lasers has been demonstrated by several groups. Other applications to fields such as chemistry, material science, plasma diagnostics, and lithography are beginning to emerge. We review the current status of soft x-ray lasers from the perspective of applications, and present an overview of the applications currently being developed

  7. Arrangement for X-ray shield

    International Nuclear Information System (INIS)

    1980-01-01

    X-ray screen unit consisting of a light transmissive carrier onto which scintillation material is deposited, which is able to generate light under the influence of incident X-ray irradiation, characterised in that the X-ray screen comprises a number of sectors, wherein the surface with respect to the incident X-radiation is maintained at an acute angle. (G.C.)

  8. X-ray spot film device

    International Nuclear Information System (INIS)

    Pury, T.; Tsen, M.L.S.; Gray, F.L.; Stehr, R.E.; Konle, R.L.

    1981-01-01

    Improvements are described in an X-ray spot film device which is used in conjunction with an X-ray table to make a selected number of radiographic exposures on a single film and to perform fluoroscopic examinations. To date, the spot film devices consist of two X-ray field defining masks, one of which is moved manually. The present device is more convenient to use and speeds up the procedure. (U.K.)

  9. Atom-resolving x-ray holography

    International Nuclear Information System (INIS)

    Adams, B.; Hiort, T.; Materlik, G.; Nishino, Y.; Novikov, D. V.

    2000-01-01

    The current state of atomic resolution x-ray holography is discussed on the basis of theory and experimental results. X-ray holography is theoretically described in quantum theory. Presently-used experimental implementations are shown together with the data analysis used. Reconstructions of experimental and simulated holograms are compared for a Cu 3 Au crystal structure. Rigorous experimental realizations of pure direct and reciprocal x-ray holography methods are demonstrated, and future developments and applications of the method are suggested

  10. Synchrotron x-ray microbeam characteristics for x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Iida, Atsuo; Noma, Takashi

    1995-01-01

    X-ray fluorescence analysis using a synchrotron x-ray microprobe has become an indispensable technique for non-destructive micro-analysis. One of the most important parameters that characterize the x-ray microbeam system for x-ray fluorescence analysis is the beam size. For practical analysis, however, the photon flux, the energy resolution and the available energy range are also crucial. Three types of x-ray microbeam systems, including monochromatic and continuum excitation systems, were compared with reference to the sensitivity, the minimum detection limit and the applicability to various types of x-ray spectroscopic analysis. 16 refs., 5 figs

  11. Nanoparticle-enhanced x-ray therapy for cancer

    Science.gov (United States)

    Letfullin, Renat R.; Rice, Colin E. W.; George, Thomas F.

    2016-03-01

    Photothermal therapies of nanophotohyperthermia and nanophotothermolysis utilize the light absorptive properties of nanoparticles to create heat and free radicals in a small localized region. Conjugating nanoparticles with various biomolecules allows for targeted delivery to specific tissues or even specific cells, cancerous cells being of particular interest. Previous studies have investigated nanoparticles at visible and infrared wavelengths where surface plasmon resonance leads to unique absorption characteristics. However, issues such as poor penetration depth of the visible light through biological tissues limits the effectiveness of delivery by noninvasive means. In other news, various nanoparticles have been investigated as contrast agents for traditional X-ray procedures, utilizing the strong absorption characteristics of the nanoparticles to enhance contrast of the detected X-ray image. Using X-rays to power photothermal therapies has three main advantages over visiblespectra wavelengths: the high penetration depth of X-rays through biological media makes noninvasive treatments very feasible; the high energy of individual photons means nanoparticles can be heated to desired temperatures with lower beam intensities, or activated to produce the free radicals; and X-ray sources are already common throughout the medical industry, making future implementation on existing equipment possible. This paper uses Lorenz-Mie theory to investigate the light absorption properties of various size gold nanoparticles over photon energies in the 1-100 keV range. These absorption values are then plugged into a thermal model to determine the temperatures reached by the nanoparticles for X-ray exposures of differing time and intensity. The results of these simulations are discussed in relation to the effective implementation of nanophotohyperthermia and nanophotothermolysis treatments.

  12. A Compact X-Ray System for Macromolecular Crystallography. 5

    Science.gov (United States)

    Gubarev, Mikhail; Ciszak, Ewa; Ponomarev, Igor; Joy, Marshall

    2000-01-01

    We describe the design and performance of a high flux x-ray system for macromolecular crystallography that combines a microfocus x-ray generator (40 gm FWHM spot size at a power level of 46.5Watts) and a 5.5 mm focal distance polycapillary optic. The Cu K(sub alpha) X-ray flux produced by this optimized system is 7.0 times above the X-ray flux previously reported. The X-ray flux from the microfocus system is also 3.2 times higher than that produced by the rotating anode generator equipped with a long focal distance graded multilayer monochromator (Green optic; CMF24-48-Cu6) and 30% less than that produced by the rotating anode generator with the newest design of graded multilayer monochromator (Blue optic; CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 Watts, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42,540 reflections collected at ambient temperature from a lysozyme crystal yielded R(sub sym) 5.0% for the data extending to 1.7A, and 4.8% for the complete set of data to 1.85A. The amplitudes of the reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model.

  13. A Compact X-Ray System for Macromolecular Crystallography

    Science.gov (United States)

    Gubarev, Mikhail; Ciszak, Ewa; Ponomarev, Igor; Gibson, Walter; Joy, Marshall

    2000-01-01

    We describe the design and performance of a high flux x-ray system for a macromolecular crystallography that combines a microfocus x-ray generator (40 micrometer full width at half maximum spot size at a power level of 46.5 W) and a collimating polycapillary optic. The Cu Ka lpha x-ray flux produced by this optimized system through a 500,um diam orifice is 7.0 times greater than the x-ray flux previously reported by Gubarev et al. [M. Gubarev et al., J. Appl. Crystallogr. 33, 882 (2000)]. The x-ray flux from the microfocus system is also 2.6 times higher than that produced by a rotating anode generator equipped with a graded multilayer monochromator (green optic, Osmic Inc. CMF24-48-Cu6) and 40% less than that produced by a rotating anode generator with the newest design of graded multilayer monochromator (blue optic, Osmic, Inc. CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 W, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42 540 reflections collected at ambient temperature from a lysozyme crystal yielded R(sub sym)=5.0% for data extending to 1.70 A, and 4.8% for the complete set of data to 1.85 A. The amplitudes of the observed reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model.

  14. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90° Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ~ 300 fs, 30 keV (0.4 Å) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been demonstrated as a

  15. Symbiotic Stars in X-rays

    Science.gov (United States)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  16. X-ray fluorescence in geology

    International Nuclear Information System (INIS)

    Dutra, C.V.; Gomes, C.B.

    1990-01-01

    This work is about the X-ray fluorescence aplication in geology. It's showing the X-ray origin and excitation. About the instrumentation this work shows the following: X-ray tubes, colimators, analysers crystals, detectors, amplifiers, pulse height selector, and others electronic components. By X-ray fluorescente are done quantitative and qualitative geological analysis and this work shows this analysis and its detection limits. The problems determination is the example. In this work was done yet the comparative analysis of the various instrumental methods in geochemistry. (C.G.) [pt

  17. X-ray pulsar rush in 1998

    International Nuclear Information System (INIS)

    Imanishi, K.; Tsujimoto, K.; Nishiuchi, Mamiko; Yokogawa, J.; Koyama, K.

    1999-01-01

    We present recent remarkable topics about discoveries of X-ray pulsars. 1. Pulsations from two Soft Gamma-ray Repeaters: These pulsars have enormously strong magnetic field (B ∼ 10 15 G), thus these are called as 'magnetar', new type of X-ray pulsars. 2. New Crab-like pulsars: These discoveries lead to suggesting universality of Crab-like pulsars. 3. An X-ray bursting millisecond pulsar: This is strong evidence for the recycle theory of generating radio millisecond pulsars. 4. X-ray pulsar rush in the SMC: This indicates the younger star formation history in the SMC. (author)

  18. X-ray speckle correlation interferometer

    International Nuclear Information System (INIS)

    Eisenhower, Rachel; Materlik, Gerhard

    2000-01-01

    Speckle Pattern Correlation Interferometry (SPCI) is a well-established technique in the visible-light regime for observing surface disturbances. Although not a direct imaging technique, SPCI gives full-field, high-resolution information about an object's motion. Since x-ray synchrotron radiation beamlines with high coherent flux have allowed the observation of x-ray speckle, x-ray SPCI could provide a means to measure strains and other quasi-static motions in disordered systems. This paper therefore examines the feasibility of an x-ray speckle correlation interferometer

  19. Compound refractive X-ray lens

    International Nuclear Information System (INIS)

    Nygren, D.R.; Cahn, R.; Cederstrom, B.; Danielsson, M.; Vestlund, J.

    2000-01-01

    An apparatus and method are disclosed for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point

  20. Ultrashort X-ray pulse science

    International Nuclear Information System (INIS)

    Chin, A.H.; Lawrence Berkeley National Lab., CA

    1998-01-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90 o Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ∼ 300 fs, 30 keV (0.4 (angstrom)) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been